WorldWideScience

Sample records for wwer-1000 steam generators

  1. Steam generator collector integrity of WWER-1000 reactors. IAEA extrabudgetary programme on the safety of WWER NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Lin, C.; Strupczewski, A. [International Atomic Energy Agency, Vienna (Austria)

    1995-12-31

    At the Consultants` Meeting on `The Safety of WWER-1000 Model 320 Nuclear Power Plants` organized by the IAEA within the framework of its Extrabudgetary Programme on the Safety of WWER-1000 NPPs, which was held in Vienna, 1-5 June 1992, the problem of WWER-1000 steam generator integrity was identified as an important issue of safety concern. Considering the safety importance of this issue, a Consultants` Meeting on `The Steam Generator Integrity of WWER-1000 Nuclear Power Plants` was convened in Vienna in May 1993, attended by 15 international experts in the area to compile information on the steam generator operating experience, deficiencies and corrective measures implemented and planned. In order to also include information from the main designer OKB Gidropress and to finalize the meeting report the IAEA convened a second meeting on the issue on 23-27 November 1993. The present paper summarizes the information and conclusions from those meetings.

  2. Steam generator collector integrity of WWER-1000 reactors. IAEA extrabudgetary programme on the safety of WWER NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Lin, C; Strupczewski, A [International Atomic Energy Agency, Vienna (Austria)

    1996-12-31

    At the Consultants` Meeting on `The Safety of WWER-1000 Model 320 Nuclear Power Plants` organized by the IAEA within the framework of its Extrabudgetary Programme on the Safety of WWER-1000 NPPs, which was held in Vienna, 1-5 June 1992, the problem of WWER-1000 steam generator integrity was identified as an important issue of safety concern. Considering the safety importance of this issue, a Consultants` Meeting on `The Steam Generator Integrity of WWER-1000 Nuclear Power Plants` was convened in Vienna in May 1993, attended by 15 international experts in the area to compile information on the steam generator operating experience, deficiencies and corrective measures implemented and planned. In order to also include information from the main designer OKB Gidropress and to finalize the meeting report the IAEA convened a second meeting on the issue on 23-27 November 1993. The present paper summarizes the information and conclusions from those meetings.

  3. Steam generator and condenser design of WWER-1000 type of nuclear power plant

    International Nuclear Information System (INIS)

    Zare Shahneh, Abolghasem.

    1995-03-01

    Design process of steam generator and condenser at Russian nuclear power plant type WWER-1000 is identified. The four chapter of the books are organized as nuclear power plant, types of steam generators specially horizontal steam generator, process of steam generator design and the description of condenser and its process design

  4. WWER-1000 steam generator integrity. A publication of the extrabudgetary programme on the safety of WWER and RBMK nuclear power plants

    International Nuclear Information System (INIS)

    1997-07-01

    Programme was initiated by IAEA in 1990 with the aim to assist the countries of Central and Eastern Europe and former Soviet Union in evaluating the safety of their first generation WWER-440/230 nuclear power plants. The main objectives were: to identify major design and operational safety issues; to establish international consensus on priorities for safety improvements; and to provide assistance in the review of the competence and and adequacy of safety improvement programs. The scope was extended in 1992 ro include RBMK, WWER-440/312 and WWER-1000 plants in operation and under construction. Based on the operational experience of more than 90 reactor years of WWER-1000 NPPs having 80 steam generators in operation or under construction the steam generator integrity was recognized as an important issue of high safety concern. The purpose of this report is to integrate available information on the issue of WWER-1000 steam generator integrity with the focus on the steam generator cold collector damage in particular. This information covers the status of stem generators at operating plants, cause analysis of collector cracking, the damage mechanisms involved, operational aspects and corrective measures developed and implemented. Consideration is given to material, design and fabrication related aspects, operational conditions, system solutions, and in-service inspection. Detailed conclusions and recommendations are provided for each of these aspects

  5. Modelling of WWER-1000 steam generators by REALP5/MOD3.2 code

    Energy Technology Data Exchange (ETDEWEB)

    D`Auria, F.; Galassi, G.M. [Univ. of Pisa (Italy); Frogheri, M. [Univ. of Genova (Italy)

    1997-12-31

    The presentation summarises the results of best estimate calculations carried out with reference to the WWER-1000 Nuclear Power Plant, utilizing a qualified nodalization set-up for the Relap5/Mod3.2 code. The nodalization development has been based on the data of the Kozloduy Bulgarian Plant. The geometry of the steam generator imposed drastic changes in noding philosophy with respect to what is suitable for the U-tubes steam generators. For the secondary side a symmetry axis was chosen to separate (in the nodalization) the hot and the cold sides of the tubes. In this way the secondary side of the steam generators was divided into three zones: (a) the hot zone including the hot collector and the hot l/2 parts of the tubes; (b) the cold zone including the cold collector and the cold 1/2 parts of the tubes; (c) the downcomer region, where down flow is assumed. As a consequence of above in the primary side more nodes are placed on the hot side of the tubes. Steady state and transient qualification has been achieved, considering the criteria proposed at the University of Pisa, utilizing plant transient data from the Kozloduy and the Ukrainian Zaporosche Plants. The results of the application of the qualified WWER-1000 Relap5/Mod3.2 nodalization to various transients including large break LOCA, small break LOCA and steam generator tube rupture, together with a sensitivity analysis on the steam generators, are reported in the presentation. Emphasis is given to the prediction of the steam generators performances. 23 refs.

  6. Modelling of WWER-1000 steam generators by REALP5/MOD3.2 code

    Energy Technology Data Exchange (ETDEWEB)

    D` Auria, F; Galassi, G M [Univ. of Pisa (Italy); Frogheri, M [Univ. of Genova (Italy)

    1998-12-31

    The presentation summarises the results of best estimate calculations carried out with reference to the WWER-1000 Nuclear Power Plant, utilizing a qualified nodalization set-up for the Relap5/Mod3.2 code. The nodalization development has been based on the data of the Kozloduy Bulgarian Plant. The geometry of the steam generator imposed drastic changes in noding philosophy with respect to what is suitable for the U-tubes steam generators. For the secondary side a symmetry axis was chosen to separate (in the nodalization) the hot and the cold sides of the tubes. In this way the secondary side of the steam generators was divided into three zones: (a) the hot zone including the hot collector and the hot l/2 parts of the tubes; (b) the cold zone including the cold collector and the cold 1/2 parts of the tubes; (c) the downcomer region, where down flow is assumed. As a consequence of above in the primary side more nodes are placed on the hot side of the tubes. Steady state and transient qualification has been achieved, considering the criteria proposed at the University of Pisa, utilizing plant transient data from the Kozloduy and the Ukrainian Zaporosche Plants. The results of the application of the qualified WWER-1000 Relap5/Mod3.2 nodalization to various transients including large break LOCA, small break LOCA and steam generator tube rupture, together with a sensitivity analysis on the steam generators, are reported in the presentation. Emphasis is given to the prediction of the steam generators performances. 23 refs.

  7. Strategy for assessment of WWER steam generator tube integrity. Report prepared within the framework of the coordinated research project on verification of WWER steam generator tube integrity

    International Nuclear Information System (INIS)

    2007-12-01

    Steam generator heat exchanger tube degradations happen in WWER Nuclear Power Plant (NPP). The situation varies from country to country and from NPP to NPP. More severe degradation is observed in WWER-1000 NPPs than in case of WWER-440s. The reasons for these differences could be, among others, differences in heat exchanger tube material (chemical composition, microstructure, residual stresses), in thermal and mechanical loadings, as well as differences in water chemistry. However, WWER steam generators had not been designed for eddy current testing which is the usual testing method in steam generators of western PWRs. Moreover, their supplier provided neither adequate methodology and criteria nor equipment for planning and implementing In-Service Inspection (ISI). Consequently, WWER steam generator ISI infrastructure was established with delay. Even today, there are still big differences in the eddy current inspection strategy and practice as well as in the approach to steam generator heat exchanger tube structural integrity assessment (plugging criteria for defective tubes vary from 40 to 90% wall thickness degradation). Recognizing this situation, the WWER operating countries expressed their need for a joint effort to develop methodology to establish reasonable commonly accepted integrity assessment criteria for the heat exchanger tubes. The IAEA's programme related to steam generator life management is embedded into the systematic activity of its Technical Working Group on Life Management of Nuclear Power Plants (TWG-LMNPP). Under the advice of the TWG-LMNPP, an IAEA coordinated research project (CRP) on Verification of WWER Steam Generator Tube Integrity was launched in 2001. It was completed in 2005. Thirteen organizations involved in in-service inspection of steam generators in WWER operating countries participated: Croatia, Czech Republic, Finland, France, Hungary, Russian Federation, Slovakia, Spain, Ukraine, and the USA. The overall objective was to

  8. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.; Keilova, E.; Krhounek, V.; Turek, J.

    1996-01-01

    The leakage and plugging limits were derived for WWER steam generators based on leak and burst tests using tubes with axial part-through and through-wall defects. The following conclusions were arrived at: (i) The permissible primary-to-secondary leak rate with respect to the permissible through-wall defect size of WWER-440 and WWER-1000 steam generator tubes is 8 l/h. (ii) The primary-to-secondary leak rate is reduced by the blocking of the tube cracks by corrosion product particles and other substances. (iii) The rate of crack penetration through the tube wall is higher than the crack widening. (iv) The validity of the criterion of instability for tubes with through-wall cracks was confirmed experimentally. For the WWER-440 and WWER-1000 steam generators, the critical size of axial through-wall cracks, for the threshold primary-to-secondary pressure difference, is 13.8 and 12.0 mm, respectively. (v) The calculated leakage for the rupture of one tube and for the assumed extreme defects is two orders and one order of magnitude, respectively, higher than the proposed primary water leakage limit of 8 l/h. (vi) The experiments gave evidence that the use of the permissible thinning limit of 80% for the heat exchange tube plugging does not bring about uncontrollable leakage or unstable crack growth. This is consistent with experience gained at WWER-440 type nuclear power plants. 4 tabs., 5 figs., 9 refs

  9. Influence of feedwater and blowdown systems on the mineral distribution in WWER steam generators

    International Nuclear Information System (INIS)

    Pappx, L.

    1994-01-01

    After modification of Dukovany NPP steam generator feedwater system, the increased concentration of minerals was measured in the cold leg of modified steam generator. Some modifications were performed on operating WWER 1000 steam generators with aim to optimize the water chemistry in the collectors area. Since the distribution of minerals can substantially affect on corrosion processes in steam generators, VITKOVICE, as a producer of WWER steam generators, has focused this attention on the optimizing of these systems. To predict the mineral distribution on the secondary side of steam generators for considered feedwater/blowdown systems, the simple model of flow distribution in the secondary side of SG was developed. (Author)

  10. Influence of feedwater and blowdown systems on the mineral distribution in WWER steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Papp, L. [Inst. of Material Engineering, Ostrava (Switzerland)

    1995-12-31

    After modification of Dukovany NPP steam generator (SG) feedwater system, the increased concentration of minerals was measured in the cold leg of modified SG. Some modifications were performed on operating WWER 1000 steam generators with aim to optimize the water chemistry in the collectors area. Since the distribution of minerals can substantially affect on corrosion processes in steam generators, VITKOVICE, as a producer of WWER steam generators has focused the attention to the optimizing of these systems. To predict the mineral distribution on the secondary side of steam generators for considered feedwater/blowdown systems, the simple model of the flow distribution in the secondary side of SG was developed.

  11. Influence of feedwater and blowdown systems on the mineral distribution in WWER steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Papp, L [Inst. of Material Engineering, Ostrava (Switzerland)

    1996-12-31

    After modification of Dukovany NPP steam generator (SG) feedwater system, the increased concentration of minerals was measured in the cold leg of modified SG. Some modifications were performed on operating WWER 1000 steam generators with aim to optimize the water chemistry in the collectors area. Since the distribution of minerals can substantially affect on corrosion processes in steam generators, VITKOVICE, as a producer of WWER steam generators has focused the attention to the optimizing of these systems. To predict the mineral distribution on the secondary side of steam generators for considered feedwater/blowdown systems, the simple model of the flow distribution in the secondary side of SG was developed.

  12. Influence of feedwater and blowdown systems on the mineral distribution in WWER steam generators

    International Nuclear Information System (INIS)

    Papp, L.

    1995-01-01

    After modification of Dukovany NPP steam generator (SG) feedwater system, the increased concentration of minerals was measured in the cold leg of modified SG. Some modifications were performed on operating WWER 1000 steam generators with aim to optimize the water chemistry in the collectors area. Since the distribution of minerals can substantially affect on corrosion processes in steam generators, VITKOVICE, as a producer of WWER steam generators has focused the attention to the optimizing of these systems. To predict the mineral distribution on the secondary side of steam generators for considered feedwater/blowdown systems, the simple model of the flow distribution in the secondary side of SG was developed

  13. WWER steam generator tube structural and leakage integrity

    International Nuclear Information System (INIS)

    Splichal, K.; Krhounek, Vl.; Otruba, J.; Ruscak, M.

    1998-01-01

    The integrity of heat exchange tubes may influence the lifetime of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirements are to assure very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evaluation and heat exchange tubes plugging. The stress corrosion cracking and pitting are the main corrosion damages of WWER heat exchange tubes and are initiated from the outer surface. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through wall cracks, oriented preferentially in the axial direction. The paper presents the leakage and plugging limits for WWER steam generators, which have been determined from leak tests and burst tests. The tubes with axial part-through and through-wall defects have been used. The permissible value of primary to secondary leak rate was evaluated with respect to permissible axial through-wall defect size of WWER 440 and 1000 steam generator tubes. Blocking of the tube cracks by corrosion product particles and other compounds reduces the primary to secondary leak rate. The plugging limits involve the following factors: permissible tube wall thickness which determine further operation of the tubes with defects and assures their integrity under operating conditions and permissible size of a through-wall crack which is sufficiently stable under normal and accident conditions in relation to the critical crack length. For the evaluation of burst test of heat exchange tubes with longitudinal through-wall defects the instability criterion has been used and the dependence of the normalised burst pressure on the normalised length of an axial through-wall defect has been determined. The validity of the criterion of instability for WWER tubes with through

  14. Safety of NPP with WWER-440 and WWER-1000 reactors

    Energy Technology Data Exchange (ETDEWEB)

    Balabanov, E [Energoproekt, Sofia (Bulgaria); Gledachev, J; Angelov, D [Kombinat Atomna Energetika, Kozloduj (Bulgaria)

    1996-12-31

    The WWER-440 and WWER-1000 reactors used at the Kozloduy NPP have been analyzed in terms of safety. There are currently 4 reactors WWER-440/230 and 2 reactors WWER-1000/320. The former do not comply completely with the modern safety requirements due to the regulations acted in the sixties when they have been designed. The main features of these reactors are: low power density in the core; three levels of reactor control and protection; six primary loops; horizontal steam generators; two turbines; large number of cross-unit connections. The low thermal density in the core, the low specific thermal loading in the rods and the large coolant inventory enhance the safety, while the major deficiencies are identified as follows: insufficient capabilities for emergency core cooling; low diversification and physical separation of the safety systems; old fashioned control systems; inadequate fire protection; lack of full containment. It is pointed out that several design and operation actions have been completed in the Kozloduy NPP in order to enhance their safety. The WWER-1000 units are 320 model and feature a high safety level, complying completely with OPB-82 regulations and with all current international safety standards. 3 refs., 7 figs., 1 tab.

  15. Safety of NPP with WWER-440 and WWER-1000 reactors

    International Nuclear Information System (INIS)

    Balabanov, E.; Gledachev, J.; Angelov, D.

    1995-01-01

    The WWER-440 and WWER-1000 reactors used at the Kozloduy NPP have been analyzed in terms of safety. There are currently 4 reactors WWER-440/230 and 2 reactors WWER-1000/320. The former do not comply completely with the modern safety requirements due to the regulations acted in the sixties when they have been designed. The main features of these reactors are: low power density in the core; three levels of reactor control and protection; six primary loops; horizontal steam generators; two turbines; large number of cross-unit connections. The low thermal density in the core, the low specific thermal loading in the rods and the large coolant inventory enhance the safety, while the major deficiencies are identified as follows: insufficient capabilities for emergency core cooling; low diversification and physical separation of the safety systems; old fashioned control systems; inadequate fire protection; lack of full containment. It is pointed out that several design and operation actions have been completed in the Kozloduy NPP in order to enhance their safety. The WWER-1000 units are 320 model and feature a high safety level, complying completely with OPB-82 regulations and with all current international safety standards. 3 refs., 7 figs., 1 tab

  16. Study on steam separation in steam generators of a NPP with the WWER-440 reactors

    International Nuclear Information System (INIS)

    Dmitriev, A.I.; Kolzov, Yu.V.; Titov, V.F.; Dubrovin, A.V.; Ilyushin, V.F.; Volkov, A.P.

    1977-01-01

    The separation characteristics as well as the actual level position in steam generators with and without a submerged holy sheet have been determined at a WWER-440 reactor nuclear power plant. It has been shown, that without changing the design of steam generators their load at the WWER-440 reactor nuclear power plant can be increased by about 10%. In this case the vapour humidity does not exceed the permissible value equal to 0.25%. The submerged holy sheet considerably decreases load irregularity and swelling of the water-steam mixture layer

  17. On the reliability of steam generator performance at nuclear power plants with WWER type reactors

    International Nuclear Information System (INIS)

    Styrikovich, M.A.; Margulova, T.Kh.

    1974-01-01

    The problem of ensuring reliable operation of steam generators in a nuclear power plant with a water-cooled, water-moderated reactor (WWER) was studied. At a nuclear power plant with a vertical steam generator (specifically, a Westinghouse product) the steam generator tubes were found to have been penetrated. Shutdown was due to corrosion disintegration of the austenitic stainless steel, type 18/8, used as pipe material for the heater surface. The corrosion was the result of the action of chlorine ions concentrated in the moisture contained in the iron oxide films deposited in low parts of the tube bundle, directly at the tube plate. Blowing through did not ensure complete removal of the film, and in some cases the construction features of the steam generator made removal of the film practically impossible. Replacement of type 18/8 stainless steel by other construction material, e.g., Inconel, did not give good results. To ensure reliable operation of vertical steam generators in domestic practice, the generators are designed without a low tube plate (a variant diagram of the vertical steam generator of such construction for the water-cooled, water-moderated reactor 1000 is presented). When low tube plates are used the film deposition is intolerable. For organization of a non-film regime a complex treatment of the feed water is used, in which the amount of complexion is calculated from the stoichmetric ratios with the composition of the feed water. It is noted that, if 100% condensate purification is used with complexon processing of the feed water to the generator, we can calculate the surface of the steam-generator heater without considering the outer placement on the tubes. In this the cost of the steam generator and all the nuclear power plants with WWER type reactors is decreased even with installation of a 100% condensate purification. It is concluded that only simultaneous solution of construction and water-regime problems will ensure relaible operation of

  18. Evaluation of the PTS potential in a WWER-1000 following a steam line break

    International Nuclear Information System (INIS)

    Beghini, M.; D'Auria, F.; Galassi, G.M.; Vitale, E.

    1997-01-01

    A qualified nodalization for WWER-1000 is available at DCMN (Dipartimento di Costruzioni Meccaniche e Nucleari) of University of Pisa that is suitable for running with the thermohydraulic system code Relap5/mod3.2. The nodalization consists of about 1400 hydraulic nodes and more than 5000 mesh points for conduction heat transfer. The four loops of the NPP are separately modelled. Detailed information about the plant hardware has been gotten from contacts with Eastern Organizations in Bulgaria, Russia and Ukraine. The qualification of the nodalization has been achieved at a steady state level utilizing a procedure available at DCMN and at a transient level on the basis of operational (planned) transients performed in the Bulgarian Kozloduy-5 NPP and of the unplanned transient occurred at the Ukrainian Zaporosche NPP (April 1995). Data measured in steam generators have also been utilized. The nodalization has been widely applied to the analysis of accident scenarios in WWER-1000, including Large Break LOCA, Small Break LOCA, ATWS, Loss of Feedwater and Station Blackout. The present activity aims at evaluating the potential for PTS (Pressurized Thermal Shock) following a steam line break accident. The thermalhydraulic results were employed as input for a parametric Fracture Mechanics analysis based on conservative hypothesis of the shape and localization of a pre-existing defect. Stress analysis evidenced the effect of partial cooling of the vessel and gave some general indications of the risk for unstable crack propagation under the simulated PTS conditions. (author). 30 refs, 17 figs, 4 tabs

  19. Evaluation of the PTS potential in a WWER-1000 following a steam line break

    Energy Technology Data Exchange (ETDEWEB)

    Beghini, M; D` Auria, F; Galassi, G M; Vitale, E [Universita degli Studi di Pisa, Dipt. di Costruzioni Meccaniche e Nucleari, Pisa (Italy)

    1997-09-01

    A qualified nodalization for WWER-1000 is available at DCMN (Dipartimento di Costruzioni Meccaniche e Nucleari) of University of Pisa that is suitable for running with the thermohydraulic system code Relap5/mod3.2. The nodalization consists of about 1400 hydraulic nodes and more than 5000 mesh points for conduction heat transfer. The four loops of the NPP are separately modelled. Detailed information about the plant hardware has been gotten from contacts with Eastern Organizations in Bulgaria, Russia and Ukraine. The qualification of the nodalization has been achieved at a steady state level utilizing a procedure available at DCMN and at a transient level on the basis of operational (planned) transients performed in the Bulgarian Kozloduy-5 NPP and of the unplanned transient occurred at the Ukrainian Zaporosche NPP (April 1995). Data measured in steam generators have also been utilized. The nodalization has been widely applied to the analysis of accident scenarios in WWER-1000, including Large Break LOCA, Small Break LOCA, ATWS, Loss of Feedwater and Station Blackout. The present activity aims at evaluating the potential for PTS (Pressurized Thermal Shock) following a steam line break accident. The thermalhydraulic results were employed as input for a parametric Fracture Mechanics analysis based on conservative hypothesis of the shape and localization of a pre-existing defect. Stress analysis evidenced the effect of partial cooling of the vessel and gave some general indications of the risk for unstable crack propagation under the simulated PTS conditions. (author). 30 refs, 17 figs, 4 tabs.

  20. WWER Steam Generators Tubing Performance and Aging Management

    International Nuclear Information System (INIS)

    Trunov, Nikolay B.; Davidenko, Stanislav E.; Grigoriev, Vladimir A.; Popadchuk, Valery S.; Brykov, Sergery I.; Karzov, Georgy P.

    2006-01-01

    At WWER NPPs the horizontal steam generators (SGs), are used that differ in design concept from vertical SGs mostly used at western NPPs. Reliable operation of SG heat-exchanging tubes is the crucial worldwide problem for NPP of various types. According to the operation feedback the water chemistry is the governing factor affecting operability of SG tubing. The secondary side corrosion is considered to be the main mechanism of SG heat-exchanging tubes damage at WWER plants. To make the assessment of the tubing integrity the combination of pressure tests and eddy-current tests is used. Assessment of the tubing performance is an important part of SG life extension practice. The given paper deals with the description of the tube testing strategy and the approach to tube integrity assessment based on deterministic and probabilistic methods of fracture mechanics. Requirements for eddy-current test are given as well. Practice of condition monitoring and implementing the database on steam generators operation are presented. The approach to tubes plugging criteria is described. The research activities on corrosion mechanism studies and residual lifetime evaluation are mentioned. (authors)

  1. Assesment of integrity of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Brozova, A.; Zdarek, J.

    1992-01-01

    Full text: The leak rates measurement project was held to give experimental data enabling the Czechoslovak Atomic Agency Inspection to decree the change in the Technical Specification allowable limit of steam generator activity release on secondary side. The WWER types of nuclear power plants in Czechoslovakia have horizontal steam generators. The tubes studying in frame of the project belong to steam generator WWER- 440 type, the diameter of tube is 16 mm, the wall thickness 1.4 mm. The subject of the project was the measurement of service leak rates of typical in service cracks. Secondary side stress corrosion cracks were determined as the typical crack created in service condition. These cracks were prepared in tubes artificially by exposition in chloride environment accompanied by an internal stress. The experimental device consisted of a pressure vessel connected with pressure water loop, a cooling vessel for leakage medium and a measuring vessel. The leak rates were determined as a slope of plots the leakage volume - time. Inside the pressure vessel the steam generator operation environment was simulated. It means: primary side of tube 12.5 MPa, Z90 deg. C, secondary side -4.6MPa, 250 deg. C, water service quality. We observed reduce of leak rate in course of time in each experiment. We suppose the tubes were stopped up by deposits formed in manufacturing of crack and in experiment. Our opinion has been proved by fractography. Project results in recommendation for in service leak rate limit based on safety factors with respect to critical crack lengths and for determination of tube plugging criteria. (author)

  2. Analysis of WWER 1000 SG cold collector cracking

    International Nuclear Information System (INIS)

    Matocha, K.; Wozniak, J.

    2000-01-01

    Following the recommendations of the 1993 consultants' meeting on 'Steam Generator Collector Integrity of WWER 1000 Reactors', an extensive experimental program was started with the aim of finding the dominant damage mechanism responsible for cold collector cracking in steam generators, and of determining whether proper operating conditions can make the operation of VITKOVICE-produced steam generators safe throughout their lifetime. The experiments consisted of: a study of the effect of strain and thermal ageing and dissolved oxygen content on subcritical crack growth in 10GN2MFA steel; a study of the effect of high temperature water and tube expansion technology on the fracture behaviour of ligaments between holes for heat exchange tubes; a study of the effect of drilling, tube expansion technology and heat treatment on residual stresses on the surface of holes for heat exchange tubes. Details of the experimental techniques used are given as well as a discussion of the results obtained and presented in tables and graphs. (A.K.)

  3. On possibility of application of the parallel-mixed type coolant flow scheme to NPP steam generators linked with superheaters

    International Nuclear Information System (INIS)

    Malkis, V.A.; Lokshin, V.A.

    1983-01-01

    Optimum distribution of the coolant straight-through flow between the superheater, evaporator and economizer is determined and the parallel-mixed type flow scheme is compared with other schemes. The calculations are performed for the 250 MW(e) steam generator for the WWER-1000 reactor unit the inlet and outlet primary coolant temperature of which is 324 and 290 deg C, respectively, while the feed water and saturation temperatures are 220 and 278.5 deg C, respectively. The rated superheating temperature is 300 deg C. The comparison of different schemes has been performed according to the average temperature head value at the steam-generator under the condition of equality as well as essential difference in the heat transfer coefficients in certain steam-generator sections. The calculations have shown that the use of parallel-mixed type flow permits to essentially increase the temperature head of the steam generator. At a constant heat transfer coefficient in all steam generator sections the highest temperature head is reached. At relative flow rates in the steam generator, economizer and evaporator equal to 6, 8 and 86%, respectively. The superheated steam generator temperature head in this case by 12% exceeds the temperature head of the WWER-1000 reactor unit wet steam generator. In case of heat transfer coefficient reduction in the superheater by a factor of three, the choice of the primary coolant, optimum distribution permits to maintain the steam generator temperature head at the level of the WWER-1000 reactor unit wet-steam steam generator. The use of the parallel-mixed type flow scheme permits to design a steam generator of slightly superheated steam for the parameters of the WWER-1000 unit

  4. Passive system with steam-water injector for emergency supply of NPP steam generators

    International Nuclear Information System (INIS)

    Il'chenko, A.G.; Strakhov, A.N.; Magnitskij, D.N.

    2009-01-01

    The calculation results of reliability indicators of emergency power supply system and emergency feed-water supply system of serial WWER-1000 unit are presented. To ensure safe water supply to steam generators during station blackout it was suggested using additional passive emergency feed-water system with a steam-water injector working on steam generators dump steam. Calculated analysis of steam-water injector operating capacity was conducted at variable parameters of steam at the entrance to injector, corresponding to various moments of time from the beginning of steam-and-water damping [ru

  5. Analysis of an accident with the main circulation tube rupture at the WWER-1000

    International Nuclear Information System (INIS)

    Boyadzhiev, A.I.; Stefanova, S.J.

    1984-01-01

    In connection with the forthcoming construction of a npp with the wwer-1000 reactor the loss of coolant accident associated with the main circulation tube rupture at the inlet near the reactor is analyzed. The relap4/mod6 program is used for the analysis. The data obtained show that the coolant outflow stage continues for about 25s. On the average the pressure in the circuits varies from 16 to 10 mpa per 0.1s and then it continues to decrease slowly. The pressure in the steam generator at the secondary circuits end increases approximately up to 6.9 MPa as a result of steam generator blocking and remaining coolant heating and then somewhat decreases owing to the primary circuit cooling. By the end of the fuel and can temperatures are equalized and the heat transfer coefficient is stabilized at the level of 100 w/1 (m 2 xK). It is concluded that during a loss of coolant accident at the wwer-1000 reactor in procesess of coolant blowdown in the medium power fuel elemets neither the fuel, melting temperature (3000 k), nor the critical temperature (1000 k) of plastic deformation zirconiu can initiation are attained

  6. Steam turbine of WWER-1000 unit

    International Nuclear Information System (INIS)

    Drahy, J.

    1986-01-01

    The manufacture was started by Skoda of a saturated steam, 1,000 MW, 3,000 rpm turbine designed for the Temelin nuclear power plant. The turbine provides steam for heating water for district heating, this either with an output of 893 MW for a three-stage water heating at 150/60 degC, or of 570 MW for a two-stage water heating at 120/60 degC. The turbine features one high-pressure and three identical low-pressure stages. The pressure gradient between the high-pressure and the low-pressure parts was optimized with respect to the thermal efficiency of the cycle and to the thermodynamic efficiency of the low-pressure part. A value of 0.79 MPa was selected corresponding to the maximum through-flow of steam entering the turbine. This makes 5,495 t/h, the admission steam parameters are 273.3 degC and 5.8 MPa. The feed water temperature is 220.9 degC. 300 cold starts, 1,000 starts after shutdowns for 55 to 88 hours and 600 starts after shutdown for 8 hours are envisaged for the entire turbine service life. (Z.M.). 5 figs., 1 tab., 6 refs

  7. Analyses of steam generator collector rupture for WWER-1000 using Relap5 code

    Energy Technology Data Exchange (ETDEWEB)

    Balabanov, E.; Ivanova, A. [Energoproekt, Sofia (Bulgaria)

    1995-12-31

    The paper presents some of the results of analyses of an accident with a LOCA from the primary to the secondary side of a WWER-1000/320 unit. The objective of the analyses is to estimate the primary coolant to the atmosphere, to point out the necessity of a well defined operator strategy for this type of accident as well as to evaluate the possibility to diagnose the accident and to minimize the radiological impact on the environment.

  8. Analyses of steam generator collector rupture for WWER-1000 using Relap5 code

    International Nuclear Information System (INIS)

    Balabanov, E.; Ivanova, A.

    1995-01-01

    The paper presents some of the results of analyses of an accident with a LOCA from the primary to the secondary side of a WWER-1000/320 unit. The objective of the analyses is to estimate the primary coolant to the atmosphere, to point out the necessity of a well defined operator strategy for this type of accident as well as to evaluate the possibility to diagnose the accident and to minimize the radiological impact on the environment

  9. Analyses of steam generator collector rupture for WWER-1000 using Relap5 code

    Energy Technology Data Exchange (ETDEWEB)

    Balabanov, E; Ivanova, A [Energoproekt, Sofia (Bulgaria)

    1996-12-31

    The paper presents some of the results of analyses of an accident with a LOCA from the primary to the secondary side of a WWER-1000/320 unit. The objective of the analyses is to estimate the primary coolant to the atmosphere, to point out the necessity of a well defined operator strategy for this type of accident as well as to evaluate the possibility to diagnose the accident and to minimize the radiological impact on the environment.

  10. ACT-1000. Group activation cross-section library for WWER-1000 type reactors

    Energy Technology Data Exchange (ETDEWEB)

    Zolotarev, K I; Pashchenko, A B [National Research Centre - A.I. Leipunsky Institute for Physics and Power Engineering, Obninsk (Russian Federation)

    2001-10-01

    The ACT-1000, a problem-oriented library of group-averaged activation cross-sections for WWER-1000 type reactors, is based on evaluated microscopic cross-section data files. The ACT-1000 data library was designed for calculating induced activity for the main dose-generated nuclides contained in WWER-1000 structural materials. In preparing the ACT-1000 library, 47 group-averaged cross-section data for the 10{sup -9}-17.33 MeV energy range were used to calculate the spatial-energy neutron flux distribution. (author)

  11. To the choice of the regeneration system of the K-1000-68/1500 turbine plant for the NPP with a vertical-type steam generator

    International Nuclear Information System (INIS)

    Kuznetsov, N.M.; Piskarev, A.A.; Grinman, M.I.; Kruglikov, P.A.

    1985-01-01

    Several variants of the heat regeneration system for the NPP with WWER-1000 type reactors using vertical steam generator (SG) generating saturated steam at 7.2 MPa pressure and 200 deg C feed water temperature at the SG inlet are considered. The results of comparison of variants in water and steam circuits of turbine plants are greatly influenced by integral economy account, i.e. efficiency indexes account under variable conditions of power unit operation. From variants of water and steam circuits of the K-1000-68/1500 turbine plant considered preference is given to the variant with four low pressure heaters with increased up to 1.25 MPa pressure in a deacrator without high pressure heater with pumping intermediate steam superheater condensate into feedwater circuit

  12. Development of new chemical and electrochemical decontamination methods for selected equipment of WWER-440 and WWER-1000 reactor primary circuit

    International Nuclear Information System (INIS)

    Solcanyi, M.; Majersky, D.

    1998-01-01

    Special devices for in-situ application of decontamination technologies assigned for Steam Generator, Pressurizer and Main Circulating Casing of WWER-1000 type were designed, manufactured and tested in real conditions of their use in above Primary Circuit components. New decontamination technologies like low-concentration process NP-NHN for the decontamination of the Steam Generator, combined chemico-mechanical treatment for the Pressurizer and semi-dry electrolysis for the Main Circulating Pump Casing were developed and approved for their safe plant application from point of view of decontamination efficiency, corrosion influence and processing of secondary wastes. Main technological parameters were defined to achieve high decontamination efficiency and corrosion-safe application of all decontamination technologies. (author)

  13. Peculiarities of cyclic deformation and fracture of heat-resistant steel 10GN2MFA under conditions typical for the steam generator PGV-1000 collector material

    International Nuclear Information System (INIS)

    Giginyak, F.F.

    1998-01-01

    In the present paper, the results are discussed concerning investigations into the regularities of deformation and fracture of steel, 10GN2MFA under conditions close to those of actual operation when used in collectors of PGV-1000-type steam generators, which are in service with WWER-1000-type reactors of nuclear power plants (NPP). (author)

  14. Horizontal steam generator PGV-1000 thermal-hydraulic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ubra, O. [Skoda Company, Prague (Switzerland); Doubek, M. [Czech Technical Univ., Prague (Switzerland)

    1995-12-31

    A computer program for the steady state thermal-hydraulic analysis of horizontal steam generator PGV-1000 is presented. The program provides the capability to analyze steam generator PGV-1000 primary side flow and temperature distribution, primary side pressure drops, heat transfer between the primary and secondary sides and multidimensional heat flux distribution. A special attention is paid to the thermal-hydraulics of the secondary side. The code predicts 3-D distribution of the void fraction at the secondary side, mass redistribution under the submerged perforated sheet and the steam generator level profile. By means of developed computer program a detailed thermal-hydraulic study of the PGV-1000 has been carried out. A wide range of calculations has been performed and a set of important steam generator characteristics has been obtained. Some of them are presented in the paper. (orig.). 5 refs.

  15. Horizontal steam generator PGV-1000 thermal-hydraulic analysis

    International Nuclear Information System (INIS)

    Ubra, O.; Doubek, M.

    1995-01-01

    A computer program for the steady state thermal-hydraulic analysis of horizontal steam generator PGV-1000 is presented. The program provides the capability to analyze steam generator PGV-1000 primary side flow and temperature distribution, primary side pressure drops, heat transfer between the primary and secondary sides and multidimensional heat flux distribution. A special attention is paid to the thermal-hydraulics of the secondary side. The code predicts 3-D distribution of the void fraction at the secondary side, mass redistribution under the submerged perforated sheet and the steam generator level profile. By means of developed computer program a detailed thermal-hydraulic study of the PGV-1000 has been carried out. A wide range of calculations has been performed and a set of important steam generator characteristics has been obtained. Some of them are presented in the paper. (orig.)

  16. Horizontal steam generator PGV-1000 thermal-hydraulic analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ubra, O [Skoda Company, Prague (Switzerland); Doubek, M [Czech Technical Univ., Prague (Switzerland)

    1996-12-31

    A computer program for the steady state thermal-hydraulic analysis of horizontal steam generator PGV-1000 is presented. The program provides the capability to analyze steam generator PGV-1000 primary side flow and temperature distribution, primary side pressure drops, heat transfer between the primary and secondary sides and multidimensional heat flux distribution. A special attention is paid to the thermal-hydraulics of the secondary side. The code predicts 3-D distribution of the void fraction at the secondary side, mass redistribution under the submerged perforated sheet and the steam generator level profile. By means of developed computer program a detailed thermal-hydraulic study of the PGV-1000 has been carried out. A wide range of calculations has been performed and a set of important steam generator characteristics has been obtained. Some of them are presented in the paper. (orig.). 5 refs.

  17. Optimization of steam generators of NPP with WWER in operation with variable load

    Science.gov (United States)

    Parchevskii, V. M.; Shchederkina, T. E.; Gur'yanova, V. V.

    2017-11-01

    The report addresses the issue of the optimal water level in the horizontal steam generators of NPP with WWER. On the one hand, the level needs to be kept at the lower limit of the allowable range, as gravity separation, steam will have the least humidity and the turbine will operate with higher efficiency. On the other hand, the higher the level, the greater the supply of water in the steam generator, and therefore the higher the security level of the unit, because when accidents involving loss of cooling of the reactor core, the water in the steam generators, can be used for cooling. To quantitatively compare the damage from higher level to the benefit of improving the safety was assessed of the cost of one cubic meter of water in the steam generators, the formulated objective function of optimal levels control. This was used two-dimensional separation characteristics of steam generators. It is demonstrated that the security significantly shifts the optimal values of the levels toward the higher values, and this bias is greater the lower the load unit.

  18. Saturated steam turbines for power reactors of WWER-type

    International Nuclear Information System (INIS)

    Czwiertnia, K.

    1978-01-01

    The publication deals with design problems of large turbines for saturated steam and with problem of output limitations of single shaft normal speed units. The possibility of unification of conventional and nuclear turbines, which creates the economic basis for production of both types of turbines by one manufacturer based on standarized elements and assemblies is underlined. As separate problems the distribution of nuclear district heating power systems are considered. The choice of heat diagram for district heating saturated steam turbines, the advantages of different diagrams and evaluaton for further development are presented. On this basis a program of unified turbines both condensing and district heating type suitable for Soviet reactors of WWER-440 and WWER-1000 type for planned development of nuclear power in Poland is proposed. (author)

  19. WWER-1000/320 steam generator collector rupture. Radiological consequences

    Energy Technology Data Exchange (ETDEWEB)

    Ivanova, A; Sartmadzhiev, A; Balabanov, E [Energoproekt, Sofia (Bulgaria)

    1996-12-31

    A model describing a hypothetical accident with direct release of primary coolant to the atmosphere is proposed. Cover lifting of the primary collector due to a rupture of the fixing bolts leads to a coolant release. The initial and boundary conditions of the accident scenario have been selected to provide for the most unfavorable conditions. The total release of primary coolant during the first 15 min of transient are estimated to 50.8 tons, of these 48.5 t with the initial activity in the primary coolant circuit. Without evacuation or sheltering, after 7 days of exposure, the expected dose at the boundary of the restricted zone is 0.0182 Sv for the whole body and 0.184 Sv for the thyroid gland. The effective equivalent dose on the site would be 0.0521 Sv. As a result of the analysis it is concluded that the steam generator collector rupture is not jeopardizing the core heat removal even with a minimum configuration of ECCS as the cooling is accomplished through the steam generators. The radiological consequences of the accident would be relatively small if an emergency procedure is applied at the 15-th minute of the transient. 1 ref.

  20. WWER-1000 Burnup Credit Benchmark (CB5)

    International Nuclear Information System (INIS)

    Manolova, M.A.

    2002-01-01

    In the paper the specification of WWER-1000 Burnup Credit Benchmark first phase (depletion calculations), given. The second phase - criticality calculations for the WWER-1000 fuel pin cell, will be given after the evaluation of the results, obtained at the first phase. The proposed benchmark is a continuation of the WWER benchmark activities in this field (Author)

  1. Structural and leakage integrity assessment of WWER steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Splichal, K.; Otruba, J. [Nuclear Research Inst., Rez (Switzerland)

    1997-12-31

    The integrity of heat exchange tubes may influence the life-time of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirement is to assure a very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evolution and heat exchange tubes plugging based on eddy current test inspection. The stress corrosion cracking and pitting are the main corrosion damage of WWER heat exchange tubes and are initiated from the outer surface. They are influenced by water chemistry, temperature and tube wall stress level. They take place under crevice corrosion condition and are indicated especially (1) under the tube support plates, where up to 90-95 % of defects detected by the ECT method occur, and (2) on free spans under tube deposit layers. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through-wall cracks, oriented above all in the axial direction. 10 refs.

  2. Structural and leakage integrity assessment of WWER steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Splichal, K; Otruba, J [Nuclear Research Inst., Rez (Switzerland)

    1998-12-31

    The integrity of heat exchange tubes may influence the life-time of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirement is to assure a very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evolution and heat exchange tubes plugging based on eddy current test inspection. The stress corrosion cracking and pitting are the main corrosion damage of WWER heat exchange tubes and are initiated from the outer surface. They are influenced by water chemistry, temperature and tube wall stress level. They take place under crevice corrosion condition and are indicated especially (1) under the tube support plates, where up to 90-95 % of defects detected by the ECT method occur, and (2) on free spans under tube deposit layers. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through-wall cracks, oriented above all in the axial direction. 10 refs.

  3. Structural and leakage integrity assessment of WWER steam generator tubes

    International Nuclear Information System (INIS)

    Splichal, K.; Otruba, J.

    1997-01-01

    The integrity of heat exchange tubes may influence the life-time of WWER steam generators and appears to be an important criterion for the evaluation of their safety and operational reliability. The basic requirement is to assure a very low probability of radioactive water leakage, preventing unstable crack growth and sudden tube rupture. These requirements led to development of permissible limits for primary to secondary leak evolution and heat exchange tubes plugging based on eddy current test inspection. The stress corrosion cracking and pitting are the main corrosion damage of WWER heat exchange tubes and are initiated from the outer surface. They are influenced by water chemistry, temperature and tube wall stress level. They take place under crevice corrosion condition and are indicated especially (1) under the tube support plates, where up to 90-95 % of defects detected by the ECT method occur, and (2) on free spans under tube deposit layers. Both the initiation and crack growth cause thinning of the tube wall and lead to part thickness cracks and through-wall cracks, oriented above all in the axial direction

  4. Lifetime forecasting of a WWER NPP steam generator tube bundle from stress corrosion conditions

    International Nuclear Information System (INIS)

    Sereda, E.V.; Gorbatykh, V.P.

    1984-01-01

    An approach is outlined to the description of corrosion cracking of austenitic stainless steels in hot chloride solutions to predict the failure of WWER NPP steam generator heat exchange tubes. The dependence of the corrosion cracking development rate on the chloride concentration and characteristic electrochemical potentials is suggsted. The approach permits also to determine the quantity of damaged tubes versus the operation parameters

  5. Problem Oriented Neutron-Gamma Cross Sections Libraries for WWER-440 and WWER-1000 Shielding and Reactor Vessel Dosimetry Application

    International Nuclear Information System (INIS)

    Belousov, S.; Antonov, S.; Ilieva, K.

    1997-01-01

    The 47 neutron and 20 gamma group libraries BGL-440 and BGL-1000 for the shielding and reactor vessel dosimetry application have been generated for WWER-440 and WWER-1000 by collapsing the VITAMIN-B6 library (199 neutron and 42 gamma groups on the base of ENDF/B-6). The first parts of the libraries for neutron-gamma transport calculation, BGL-440-1 (150 nuclides) and BGL-1000-1 (140 nuclides), have been generated by a modified version of SAS1X control module of the SCALE system. The appropriate zone-average neutron flux had been used for these sub-libraries collapsing. The BGL-440-2 and BGL-1000-2 sub-libraries consist of cross sections for all 120 nuclides of VITAMIN-B6, for calculation of the transport through non-reactor materials of dosimeters, capsules, specimens which may be placed in the cavity behind the reactor vessel. The neutron spectrum just beyond the RPV had been used for this collapsing. As the first test the comparative calculations of the neutron flux on/behind the WWER-1000 reactor vessel have been realised using the libraries BGL-1000 and BUGLE, intended for the American PWR reactors. The integral neutron flux values by BGL-1000 and BUGLE differ by 3% onto the vessel, and 5% behind the vessel. This result shows that the calculations of the neutron flux responses for the WWER vessel surveillance, especially in locations behind the WWER vessel have to be done by the appropriate BGL library. Key words: neutron transport, multigroup neutron cross section libraries

  6. Approach to normalization of the secondary circuit water chemistry of NPP with WWER-1000

    International Nuclear Information System (INIS)

    Mamet, V.A.; Erpyleva, S.F.; Banyuk, G.F.

    1998-01-01

    The approach to normalization if indices of water-chemical regime of the secondary circuit of the NPP with WWER-1000 reactor, based on pH calculational values at the coolant working temperature in dependence on the normalized admixtures concentration is considered. The possibility for conducting the water regime of steam generators by the ratio of sodium concentration and electrical conductivity of H-cation sample of blow-through water is shown. The limitations (os action level) by deviation of normalized indices from recommended ones for normal operational conditions are described

  7. On the heat exchange tube failures in steam generators at NPPs with WWER reactors

    International Nuclear Information System (INIS)

    Titov, V.F.; Banyuk, G.F.; Brykov, S.I.

    1992-01-01

    Data on dynamics of failed heat exchanging tube closing in steam generators of NPPs with WWER type reactors for the whole period of their operation are presented. It is shown that the main cause of the tube failures consists in their corrosion cracking under stresses. The effect of chlorine ions on tubes is intensified by the presence of porous sediments on heat exchaning surfaces in quantities exceeding 150 g/m 2

  8. Thermal-hydraulic characteristic of the PGV-1000 steam generator

    International Nuclear Information System (INIS)

    Ubra, O.; Doubek, M.

    1995-01-01

    Horizontal steam generators are typical parts of nuclear power plants with pressure water reactor type VVER. By means of this computer program, a detailed thermal-hydraulic study of the horizontal steam generator PGV-1000 has been carried out and a special attention has been paid to the thermal-hydraulics of the secondary side. A set of important steam generator characteristics has been obtained and analyzed. Some of the interesting results of the analysis are presented in the paper. (author)

  9. Radiation embrittlement of WWER-1000 reactor vessel steels

    International Nuclear Information System (INIS)

    Nikolaeva, A.V.; Nikolaev, Yu.A.; Kevorkyan, Yu.R.

    2001-01-01

    Results obtained on the blank samples of materials of the WWER-1000 vessels irradiated by low density neutron flux are discussed. Chemical composition of the materials is characterized by the low content of the impurities (copper and phosphorus) and high content of nickel. Dependence of the radiation embrittlement of the WWER-1000 vessel materials on metallurgic variables and damage dose is treated. The research showed that nickel largely enhanced the radiation embrittlement. New dependences for determination of the radiation embrittlement real rate of the WWER-1000 vessel materials and its conservative estimation were developed [ru

  10. IAEA activities on steam generator life management

    International Nuclear Information System (INIS)

    Gueorguiev, B.; Lyssakov, V.; Trampus, P.

    2002-01-01

    The International Atomic Energy Agency (IAEA) carries out a set of activities in the field of Nuclear Power Plant (NPP) life management. Main activities within this area are implemented through the Technical Working Group on Life Management of NPPs, and mostly concentrated on studies of understanding mechanisms of degradation and their monitoring, optimisation of maintenance management, economic aspects, proven practices of and approaches to plant life management including decommissioning. The paper covers two ongoing activities related to steam generator life management: the International Database on NPP Steam Generators and the Co-ordinated Research Project on Verification of WWER Steam Generator Tube Integrity (WWER is the Russian designed PWR). The lifetime assessment of main components relies on an ability to assess their condition and predict future degradation trends, which to a large extent is dependent on the availability of relevant data. Effective management of ageing and degradation processes requires a large amount of data. Several years ago the IAEA started to work on the International Database on NPP Life Management. This is a multi-module database consisting of modules such as reactor pressure vessels materials, piping, steam generators, and concrete structures. At present the work on pressure vessel materials, on piping as well as on steam generator is completed. The paper will present the concept and structure of the steam generator module of the database. In countries operating WWER NPPs, there are big differences in the eddy current inspection strategy and practice as well as in the approach to steam generator heat exchanger tube structural integrity assessment. Responding to the need for a co-ordinated research to compare eddy current testing results with destructive testing using pulled out tubes from WWER steam generators, the IAEA launched this project. The main objectives of the project are to summarise the operating experiences of WWER

  11. Steam generator design requirements for ACR-1000

    International Nuclear Information System (INIS)

    Subash, S.; Hau, K.

    2006-01-01

    Atomic Energy of Canada Limited (AECL) has developed the ACR-1000 (Advanced CANDU Reactor-1000 ) to meet market expectations for enhanced safety of plant operation, high capacity factor, low operating cost, increased operating life, simple component replacement, reduced capital cost, and shorter construction schedule. The ACR-1000 design is based on the use of horizontal fuel channels surrounded by a heavy water moderator, the same feature as in all CANDU reactors. The major innovation in the ACR-1000 is the use of low enriched uranium fuel, and light water as the coolant, which circulates in the fuel channels. This results in a compact reactor core design and a reduction of heavy water inventory, both contributing to a significant decrease in capital cost per MWe produced. The ACR-1000 plant is a two-unit, integrated plant with each unit having a nominal gross output of about 1165 MWe with a net output of approximately 1085 MWe. The plant design is adaptable to a single unit configuration, if required. This paper focuses on the technical considerations that went into developing some of the important design requirements for the steam generators for the ACR-1000 plant and how these requirements are specified in the Technical Specification, which is the governing document for the steam generator (SG) detail design. Layout of these SGs in the plant is briefly described and their impacts on the SG design. (author)

  12. The main conditions ensured problemless implementation of 235U high enriched fuel in Kozloduy NPP (Bulgaria) - WWER-1000 Units

    International Nuclear Information System (INIS)

    Dobrevski, I.; Zaharieva, N.; Minkova, K.; Michaylov, G.; Penev, P.; Gerchev, N.

    2009-01-01

    The collected water chemistry and radiochemistry data during the operation of the Kozloduy NPP Unit 5 for the period 2006-2009 (12-th, 13-th 14-th and 15-th fuel cycles) undoubtedly indicate for WWER-1000 Units (whose specific features are: Steam generators with austenitic stainless steel 08Cr18N10T tubing; Steam generators are with horizontal straight tubing and Fuel elements cladding material is Zr-1%Nb (Zr1Nb) alloy), that one realistic way for problemless implementation of 235 U high enriched fuel have been found. The main feature characteristics of this way are: Implementation of solid neutron burnable absorbers together with the dissolved in coolant neutron absorber - natural boric acid; Application of fuel cladding materials with enough corrosion resistance by the specific fuel cladding environment created by presence of SNB; Keeping of suitable coolant water chemistry which ensures low corrosion rates of core- and out-of-core- materials and limits in core (cladding) depositions and restricts out-of-core radioactivity buildup. The realization of this way in WWER-1000 Units in Kozloduy NPP was practically carried out through: 1) Implementation of Russian fuel assemblies TVSA which have as fuel cladding material E-110 alloy (Zr1Nb) with enough high corrosion resistance by presence of sub-cooled nucleate boiling (SNB) and use burnable absorber (Gd) integrated in the uranium-gadolinium (U-Gd 2 O 3 ) fuel (fuel rod with 5.0% Gd 2 O 3 ); 2) Development and implementation of water chemistry primary circuit guidelines, which require the relation between boric acid concentration and total alkalising agent concentrations to ensure coolant pH 300 = 7.0 - 7.2 values during the whole operation period. The above mentioned conditions by the passing of WWER-1000 Units in NPP Kozloduy to uranium fuel with 4.4% 235 U (TVSA fuel assemblies) practically ensured avoidance of the creation of the necessary conditions for AOA onset. The operational experience (2006-2009) of the

  13. Effect of high-temperature filtration on impurity composition in the primary circuit coolant of power units with WWER-1000 reactors

    International Nuclear Information System (INIS)

    Efimov, A.A.; Moskvin, L.N.; Gusev, B.A.; Leont'ev, G.G.; Nekrest'yanov, S.N.

    1992-01-01

    The effects of high-temperature filtration on changes in dispersive, chemical, radioisotope and phase compositions of impurities in primary circuit coolant of NPP with the WWER-1000 reactor are studied. Special filters are used for the studies. The data obtained confirm the applicability of high-temperature filtration for purification of WWER reactor water and steam separators at NPPs with RBMK reactors

  14. EddyOne automated analysis of PWR/WWER steam generator tubes eddy current data

    International Nuclear Information System (INIS)

    Nadinic, B.; Vanjak, Z.

    2004-01-01

    INETEC Institute for Nuclear Technology developed software package called Eddy One which has option of automated analysis of bobbin coil eddy current data. During its development and on site use, many valuable lessons were learned which are described in this article. In accordance with previous, the following topics are covered: General requirements for automated analysis of bobbin coil eddy current data; Main approaches to automated analysis; Multi rule algorithms for data screening; Landmark detection algorithms as prerequisite for automated analysis (threshold algorithms and algorithms based on neural network principles); Field experience with Eddy One software; Development directions (use of artificial intelligence with self learning abilities for indication detection and sizing); Automated analysis software qualification; Conclusions. Special emphasis is given on results obtained on different types of steam generators, condensers and heat exchangers. Such results are then compared with results obtained by other automated software vendors giving clear advantage to INETEC approach. It has to be pointed out that INETEC field experience was collected also on WWER steam generators what is for now unique experience.(author)

  15. Improvement of operational performance and increase of safety of WWER-1000/V-392

    International Nuclear Information System (INIS)

    Kurakov, Y.A.; Dragunov, Y.G.; Podshibiakin, A.K.; Fil, N.S.; Krushelnitsky, V.N.; Berkovich, V.M.

    2001-01-01

    The national programme of nuclear power development approved by the Russian Federation Government in 1998 considers the design of WWER-1000/V-392 power unit as a priority project of the new generation NPP with improved operational performances and increased safety. The pilot unit of this design (NVAES-2) is licensed for construction at the Novovoronezh NPP site. The NVAES-2 design is developed on the basis of standard power unit with reactor plant V-320. Twenty units of this type are in operation at the nuclear power plants in Russia, Ukraine and Bulgaria having totally about 270 reactor-years of operation. Two more V-320 units are being commissioned this year at Rostov NPP and Temelin NPP. So, the WWER-1000/V-392 design is as a whole an evolutionary development of the operating standard unit WWER-1000/V-320. Many technical solutions aimed at increase of safety and improvement of operational performance of the plant are implemented in the NVAES-2 design, such as advanced reactor WWER-1000, passive system of residual power removal, passive system of the core flooding under loss-of-coolant accidents, and others. NVAES-2 design refers to a class of advanced light water reactors and corresponds to the international requirements imposed to the nuclear power plants to be put into operation after the year 2000. New V-392 power unit has a good perspective from the view point of extensive implementation in the framework of the nuclear electricity production in Russia. Design decisions on NVAES-2 power unit with WWER-1000/V-392 reactor plant which assure significantly higher safety level and improve economical performance as compared to the operating WWER-1000 units are briefly considered in the present paper. (author)

  16. Analysis of operating reliability of WWER-1000 unit

    International Nuclear Information System (INIS)

    Bortlik, J.

    1985-01-01

    The nuclear power unit was divided into 33 technological units. Input data for reliability analysis were surveys of operating results obtained from the IAEA information system and certain indexes of the reliability of technological equipment determined using the Bayes formula. The missing reliability data for technological equipment were used from the basic variant. The fault tree of the WWER-1000 unit was determined for the peak event defined as the impossibility of reaching 100%, 75% and 50% of rated power. The period was observed of the nuclear power plant operation with reduced output owing to defect and the respective time needed for a repair of the equipment. The calculation of the availability of the WWER-1000 unit was made for different variant situations. Certain indexes of the operating reliability of the WWER-1000 unit which are the result of a detailed reliability analysis are tabulated for selected variants. (E.S.)

  17. Enhanced Westinghouse WWER-1000 fuel design for Ukraine reactors

    International Nuclear Information System (INIS)

    Dye, M.; Shah, H.

    2015-01-01

    Westinghouse has completed design, development, and region quantity delivery of an enhanced Westinghouse fuel assembly for WWER-1000 reactors to support continued safe reactor operations. The enhanced design builds on the successful performance of an earlier generation design which has operated in the South Ukraine 3 reactor for multiple cycles without any fuel rod failures. Incorporated design enhancements include a thicker spacer grid outer strap, an enhanced spacer grid outer strap profile to limit the risk for, and impact of, mechanical interaction/interference with coresident fuel, an all Alloy 718 grid structure for improved stability and strength, and improvements to the top and bottom nozzles. Capable of meeting increased lateral loads generated from using a higher axial trip limit for the refueling machine crane, the design was verified by extensive mechanical and thermalhydraulic testing, which included a newly developed fuel assembly-to-fuel assembly handling test rig to assess performance during bounding core loading and unloading conditions. Through these extensive design enhancements and comprehensive testing program, the enhanced WWER-1000 design provides additional performance, handling, and reliability margins for safe reactor operation. (authors)

  18. Vibrations as a contributor to the cracking of PGV-1000 steam generator cold collector

    International Nuclear Information System (INIS)

    Verezemskij, V.G.

    1997-01-01

    The results of multiple investigations of cold collector ruptures at NPPs with WWER-1000 reactor as a complex and multi-parameter process are generalized. It is shown that the temperature of cold collector operation (280-290 deg C) at which environment corrosion effects are maximum has an important role for revealing the factors causing the damage. When the reactor plant operates under stationary and transient conditions the primary coolant circuit equipment, main circulation pipelines and main steam lines become involved into vibrations with different intensities as a result of pressure pulsations at reverse and multiple frequencies of the main circulation pumps connected with formation of standing pressure waves in the primary circuit and steam lines. The analysis made gives an opportunity to conclude that dynamic loads (vibrations) play the leading part in reaching the limits of cold collector metal cyclic strength and its cracking. It means that the measures for cold collector service life increasing should be directed on vibration amplitude lowering and cyclic stress decreasing

  19. Examples for cost reduction in the design of a WWER-1000 nuclear power plant

    International Nuclear Information System (INIS)

    Kukkola, T.

    1991-01-01

    In a design project during recent years, a version for Finnish conditions has been and is being developed based on the Soviet WWER-1000 PWR plant with four horizontal steam generators. The plant will have a double containment. The inner containment will be a dry full pressure prestressed concrete containment with liner and the secondary containment will be made of ordinary concrete. Four train safety approach is adopted. It is supposed that the plant is to be designed according to the present Finnish safety requirements, e.g. severe reactor accidents are considered. When striving at an economic plant no compromises are made as far as safety is concerned. This paper describes possible cost reduction by redesigning the main technical equipment. (author). 1 ref

  20. Fuel improvement and WWER-1000 FA main operational results

    International Nuclear Information System (INIS)

    Rozhkov, V.; Enin, A.; Bezborodov, Y.; Petrov, V.

    2003-01-01

    The JSC NCCP experience of WWER-1000 Fuel Assemblies (FAs) fabrication and operation confirms the adequate feasibility and efficiency of fuel operation in 3-4-x fuel cycles, high operating reliability and competitive capacity as compared with foreign analogues. The work on fuel improvement is aimed at an improvement of the operating reliability and an enhancement of the fuel use efficiency in WWER-1000 advanced FAs

  1. Performance of the Westinghouse WWER-1000 fuel design

    International Nuclear Information System (INIS)

    Hoglund, J.; Riznychenko, O.; Latorre, R.; Lashevych, P.

    2011-01-01

    In 2005 six (6) Westinghouse WWER-1000 Lead Test Assemblies (LTAs) were loaded in the South Ukraine Unit 3. This design has demonstrated full compatibility with resident fuel designs and all associated fuel handling and reactor components. Operations have further demonstrated adequacy of performance margins and the reliability requirements for multiple cycles of operation. The LTA's have now been discharged after completing the planned four cycles of operation and having reached an average assembly burnup in excess of 43 MWd/kgU. Post Irradiation Examinations were performed after completion of each cycle. The final LTA inspection program at end of Cycle 20 in 2010 yielded satisfactory results on all counts, and it was concluded that the 6 Westinghouse LTA's performed as expected during their operational regimes. Very good performance was demonstrated in the WWER-1000 reactor environment for the Zr-1%Nb as grid material, and ZIRLO fuel cladding and structural components. Control Rod Assemblies drop times and drag forces were all within the accepted values. The LTA program demonstrated that this fuel design is suitable for full core applications. However, the topic of fuel assembly distortion resistance was re-visited and Westinghouse therefore considered operational experience and design features from multiple development programs to enhance the basic Westinghouse WWER-1000 fuel design for Ukrainian reactors. The design now includes features that further mitigate assembly bow while at the same time improving the fuel cycle economy. This paper describes briefly the development of the Westinghouse WWER-1000 fuel design and how test results and operational experiences from multiple sources have been utilized to produce a most suitable fuel design. Early in 2011 a full region of the Westinghouse WWER-1000 design completed another full cycle of operation at South Ukraine Unit 3, all with excellent results. All 42 fuel assemblies were examined for visible damage or non

  2. Mathematical modelling of stress-deformation state of the steam generator collector (WWER-type) under pressure loading during fracture mechanics calculations

    International Nuclear Information System (INIS)

    Zaitsev, M.; Lyssakov, V.

    1993-01-01

    This paper describes a steam generator collector (WWER-type) designed as part of a Russian reactor power station. The collector is a thick cylindrical shell with a constant inner diameter of 850 mm and a height of 4,970 mm. The wall thickness varies from 78 to 163 mm. In the thicker section, a series of holes allows connection of steam generator heat exchanging tubes. Because of design considerations, the tubes are not symmetrically located about the circumference of the collector. This paper presents a model of the stress concentrations resulting from this design feature for a device operating at a nominal pressure of 16 MPa. 4 refs., 8 figs

  3. Concentration of WWER-1000 unit power on one site

    International Nuclear Information System (INIS)

    Rousek, J.; Kysel, J.; Sladek, V.

    1987-01-01

    The problem of a suitable number of nuclear power plant units built on one site is discussed. Using an example of three sites being prepared now in Czechoslovakia, two alternatives - one with two WWER-1000 units, the other with four WWER-1000 units on one site - are evaluated from the viewpoint of long-range nuclear power development program in Czechoslovakia, costs, transmission of electric power and heat supply. (author). 10 tabs., 13 refs

  4. Automated WWER steam generator eddy current testing and plugging control system

    International Nuclear Information System (INIS)

    Gorecan, I.; Gortan, K.; Grzalja, I.

    2004-01-01

    The structural architecture of the system contains three main components which are described as follows: Manipulator Guidance System; Eddy Current Testing System; Plugging System. The manipulator system has the task to position the end-effectors to the desired tube position. When the final position is reached, the Eddy Current testing system performs data acquisition. In case defects are found, the plugging system performs tube plug installment. Each system is composed of 3 layers. The first layer is the hardware layer consisting of motors driving the effectors along with sensors needed to obtain the positioning data, pusher motors used to push the test probes into tubes of the WWER steam generator, and plugging hardware tool. The second layer is the control box performing basic monitoring and control routines as an interconnection between first and third layer. The highest layer is the control software, running on the PC, which is used as a human-machine-interface.(author)

  5. Modelling of WWER-1000 fuel: state and prospects

    International Nuclear Information System (INIS)

    Medvedev, A.; Bibilashvili, Yu.; Bogatyr, S.; Khvostov, G.

    1994-01-01

    The role of START-3 code in studying and computerized modelling of post-irradiation behaviour of standard fuel rods in real operation conditions of WWER-1000 reactors is described. The models used in the code are based on experimental study of material properties, processes and post irradiation research on standard and experimental fuel pins. The code capability is verified by comparison with data from experiments on WWER test rods performed in MR reactor, the Russia-Finland tests SOFIT and the international program FUMEX. The comparison performed and the results thus obtained demonstrate the satisfactory ability of START-3 code to simulate fuel rod behaviour in normal operation condition. The calculations confirm the experimentally observed evidence of an essential margin on serviceability of WWER-1000 fuel pin with three year operation cycle permitting an increase in design fuel burnup. 2 tabs., 18 figs

  6. Modelling of WWER-1000 fuel: state and prospects

    Energy Technology Data Exchange (ETDEWEB)

    Medvedev, A; Bibilashvili, Yu; Bogatyr, S; Khvostov, G [Vsesoyuznyj Nauchno-Issledovatel` skij Inst. Neorganicheskikh Materialov, Moscow (Russian Federation)

    1994-12-31

    The role of START-3 code in studying and computerized modelling of post-irradiation behaviour of standard fuel rods in real operation conditions of WWER-1000 reactors is described. The models used in the code are based on experimental study of material properties, processes and post irradiation research on standard and experimental fuel pins. The code capability is verified by comparison with data from experiments on WWER test rods performed in MR reactor, the Russia-Finland tests SOFIT and the international program FUMEX. The comparison performed and the results thus obtained demonstrate the satisfactory ability of START-3 code to simulate fuel rod behaviour in normal operation condition. The calculations confirm the experimentally observed evidence of an essential margin on serviceability of WWER-1000 fuel pin with three year operation cycle permitting an increase in design fuel burnup. 2 tabs., 18 figs.

  7. Advanced fuel cycles for WWER-1000 reactors

    International Nuclear Information System (INIS)

    Semchenkov, Y. M.; Pavlovichev, A. M.; Pavlov, V. I.; Spirkin, E. I.; Styrin, Y. A.; Kosourov, E. K.

    2007-01-01

    Main stages of Russian uranium fuel development regarding improvement of safety and economics of fuel load operation are presented. Intervals of possible changes in fuel cycle duration have been demonstrated for the use of current and perspective fuel. Examples of equilibrium fuel load patterns have been demonstrated and main core neutronics parameters have been presented. Problems on the use of axial blankets with reduced enrichment in WWER-1000 fuel assemblies are considered. Some results are presented regarding core neutronic characteristics of WWER-1000 at the use of regenerated uranium and uranium-plutonium fuel. Examples of equilibrium fuel cycles for the core partially loaded with MOX fuel from weapon-grade plutonium are also considered (Authors)

  8. MOST-7 program for calculation of nonstationary operation modes of the nuclear steam generating plant with WWER

    International Nuclear Information System (INIS)

    Mysenkov, A.I.

    1979-01-01

    The MOST-7 program intended for calculating nonstationary emergency models of a nuclear steam generating plant (NSGP) with a WWER reactor is considered in detail. The program consists of the main MOST-7 subprogram, two main subprograms and 98 subprograms-functions. The MOST-7 program is written in the FORTRAN language and realized at the BESM-6 computer. Program storage capacity in the BESM-6 amounts to 73400 words. Primary information input into the program is carried out by means of information input operator from punched cards and DATA operator. Parameter lists, introduced both from punched cards and by means of DATA operator are tabulated. The procedure of calculational result output into printing and plotting devices is considered. Given is an example of calculating the nonstationary process, related to the loss of power in six main circulating pumps for NSGP with the WWER-440 reactor

  9. WWER-1000 fuel cycles: current situation and outlook

    International Nuclear Information System (INIS)

    Kosourov, E.; Pavlov, V.; Pavlovichev, A.; Spirkin, E.; Shcherenko, A.

    2013-01-01

    Usage mode of nuclear fuel in WWER type reactor has been changed significantly till the moment of the first WWER-1000 commissioning. There are a lot of improvements, having an impact on the fuel cycle, have been implemented for units with WWER-1000. FA design and its constructional materials, FA fuel weight, burnable poison, usage mode of units and etc have been modified. As the result of development it has been designed a modern FA with rigid skeleton. As a whole it allows to use more efficient configurations of the core, to extend range of fuel cycle lengths and to provide good flexibility in the operation. In recent years there were in progress works on increasing FA uranium capacity. As the result there were developed two designs of the fuel rod: 1) the fuel column height of 3680 mm, diameters of the fuel pellet and its central hole of 7.6 and 1.2 mm respectively and 2) the fuel column height of 3530 mm, the fuel pellet diameter of 7.8 mm without the central hole. Such fuel rods have operating experience as a part of different FA designs. Positive operating experience was a base of new FA (TVS-4) development with the fuel column height of 3680 mm and the fuel pellet diameter of 7.8 mm without the central hole. The paper presents the overview of WWER-1000, AES-2006 and WWER-TOI fuel cycles based on FAs with fuel rod designs described above. There are demonstrated fuel cycle possibilities and its technical and economic characteristics. There are discussed problems of further fuel cycle improvements (fuel enrichment increase above 5 %, use of erbium as alternative burnable poison) and their impact on neutronics characteristics. (authors)

  10. Comparative analysis of exercise 2 results of the OECD WWER-1000 MSLB benchmark

    International Nuclear Information System (INIS)

    Kolev, N.; Petrov, N.; Royer, E.; Ivanov, B.; Ivanov, K.

    2006-01-01

    In the framework of joint effort between OECD/NEA, US DOE and CEA France a coupled three-dimensional (3D) thermal-hydraulic/neutron kinetics benchmark for WWER-1000 was defined. Phase 2 of this benchmark is labeled W1000CT-2 and consists of calculation of a vessel mixing experiment and main steam line break (MSLB) transients. The reference plant is Kozloduy-6 in Bulgaria. Plant data are available for code validation consisting of one experiment of pump start-up (W1000CT-1) and one experiment of steam generator isolation (W1000CT-2). The validated codes can be used to calculate asymmetric MSLB transients involving similar mixing patterns. This paper summarizes a comparison of the available results for W1000CT-2 Exercise 2 devoted to core-vessel calculation with imposed MSLB vessel boundary conditions. Because of the recent re-calculation of the cross-section libraries, core physics results from PARCS and CRONOS codes could be compared only. The comparison is code-to-code (including BIPR7A/TVS-M lib) and code vs. plant measured data in a steady state close to the MSLB initial state. The results provide a test of the cross-section libraries and show a good agreement of plant measured and computed data. The comparison of full vessel calculations was made from the point of view of vessel mixing, considering mainly the coarse-mesh features of the flow. The FZR and INRNE results from multi-1D calculations with different mixing models are similar, while the FZK calculations with a coarse-3D vessel model show deviations from the others. These deviations seem to be due to an error in the use of a boundary condition after flow reversal (Authors)

  11. Application of the LBB concept to nuclear power plants with WWER 440 and WWER 1000 reactors

    Energy Technology Data Exchange (ETDEWEB)

    Zdarek, J.; Pecinka, L. [Nuclear Research Institute Rez (Czech Republic)

    1997-04-01

    Leak-before-break (LBB) analysis of WWER type reactors in the Czech and Sloval Republics is summarized in this paper. Legislative bases, required procedures, and validation and verification of procedures are discussed. A list of significant issues identified during the application of LBB analysis is presented. The results of statistical evaluation of crack length characteristics are presented and compared for the WWER 440 Type 230 and 213 reactors and for the WWER 1000 Type 302, 320 and 338 reactors.

  12. Application of the LBB concept to nuclear power plants with WWER 440 and WWER 1000 reactors

    International Nuclear Information System (INIS)

    Zdarek, J.; Pecinka, L.

    1997-01-01

    Leak-before-break (LBB) analysis of WWER type reactors in the Czech and Sloval Republics is summarized in this paper. Legislative bases, required procedures, and validation and verification of procedures are discussed. A list of significant issues identified during the application of LBB analysis is presented. The results of statistical evaluation of crack length characteristics are presented and compared for the WWER 440 Type 230 and 213 reactors and for the WWER 1000 Type 302, 320 and 338 reactors

  13. Domestic design and validation of natural circulation steam generator of China 1000 MWe PWR NPP

    International Nuclear Information System (INIS)

    Liu, H.Y.; Wang, X.Y.; Wu, G.; Qin, J.M.; Xiong, Ch.H.; Wang, W.; Chen, J.L.; Cheng, H.P.; Zuo, Ch.P.

    2005-01-01

    In order to meet the requirements of domestic design of China intending built NPP projects, Research Institute of Nuclear Power Operation (RINPO) has achieved design of 1000 MWe NPP steam generator, called RINSG-1000(means 1000MWe SG designed by RINPO), which is based on SG research ,experiments and service experience accumulated by RINPO in more 40 years. Testing validation of two steam generator key technologies, advanced moisture separate device and sludge collector, has been accomplished during the period of 2000 to 2002. This paper describes the design features of RINSG-1000, and provides some validation test results. (authors)

  14. Steam feeding redundancy for turbine-drives of feed pumps at WWER-1000 NPP

    International Nuclear Information System (INIS)

    Nesterov, Yu.V.; Shmukler, B.I.

    1987-01-01

    The system of steam supply for feed pump driving turbines (T) at the South Ukrainian Unit 1 according to the centralized redundancy principle is described. T is feeded through the collector of water auxiliary sytem (CWAS) to which steam from the third steam extraction line of turbine is supplied under thenormal regime. Under the reduction of turbine load, live steam from the steam generator is supplied to CWAS through the pressure regulator, possesing 10 s speed of responce. In this case the level reduction in the steam generator makes up 170 mm

  15. Strength analysis of PGV-1000M steam generator support

    International Nuclear Information System (INIS)

    Dubik, Ya.R.; Ageev, S.M.; Orynyak, I.V.; Vasilchenko, B.M.

    2017-01-01

    The paper presents the design of PGV-1000M steam generator support. It is shown that the load in the rolling support is distributed extremely unevenly, which is associated with the compliance of the support construction. It is demonstrated that under working loads only several rollers are used, the stresses in which exceed the yield strength. This can be an additional loading factor to be considered in the analysis of welding No. 111 failure.

  16. Experience in scientific guidance during start-up and normal operation of NPPs with WWER reactors; Opyt nauchnogo rukovodstva puskom i soprovozhdeniya pri ehkspluatatsii ehnergoblokov AEhS s WWER

    Energy Technology Data Exchange (ETDEWEB)

    Abagyan, A; Kazakov, V; Kryakvin, L [All-Russian Inst. for NPP Operation, Moscow (Russian Federation)

    1996-12-31

    The experience gained in the All-Russian Research Institute of NPP Operation (RU) in improvement of reactor start-up and normal operation of NPPs has been reported. The work was carried out on NPPs in Russia, Ukraine, Bulgaria, Hungary and Czechoslovakia. All scientific programmes applied use the system approach, modern methods of safety assessment and the principle of loss effect optimization. For the Kozloduy NPP the following projects have been implemented: design of accelerated unloading system for WWER-1000; refinement of water feeding unit for the WWER-1000 steam generator; response analysis of the safety anti-breakdown system of the second loop. The importance of technical substantiation in the process of decision making is stressed. 6 refs.

  17. An investigation of axial xenon stability in WWER-1000 reactor designs

    International Nuclear Information System (INIS)

    Doshi, P.K.; Miller, R.W.

    1993-01-01

    The nuclear power plants of the WWER-1000 design have experienced frequent xenon oscillation control problems. In most PWRs, xenon oscillations are largely a problem in the axial direction. An one dimensional core model representative of the WWER-1000 design was set up to examine the controllability of the current design. An investigation of possible improvements to this design was made. There was no indication that xenon oscillations were an inherent problem in WWER-1000 core design. Simple changes to the control rod system coupled with a sound power distribution control strategy that has been proven to be an effective but simple procedure to follow, eliminate xenon control problems. The changes proposed can be implemented in a very cost effective manner. There are no equipment changes needed, existing control rods can be used. Only software changes are required. (Z.S.) 1 tab., 2 figs., 7 refs

  18. Nuclear power plants with reactors WWER-1000 type: today and tomorrow; AEhS s WWER-1000: nastoyashchee i budushchee

    Energy Technology Data Exchange (ETDEWEB)

    Molchanov, V; Biryukov, G; Novak, K [Opytno-Konstruktorskoe Byuro Gidropress, Podol` sk (Russian Federation)

    1996-12-31

    There are currently 19 NPP units based on WWER-1000 reactors working in Russia, Ukraine and Bulgaria. They are of four types: V-187, V-302, V-338, V-320. The design principles of these reactors comply with regulations of the eighties, and it is necessary to introduce improvements according to the new regulations and to the operation experience gained. Two approaches for safety and efficiency enhancement are described: AS-91 and AS-92. AS-91 implies gradual improvement of the base WWER-1000/V-320 design by incorporation of new design solutions avoiding the need of building large scale models. AS-92 refers to entirely new design which require experimental research by building a full scale models or by using natural stands. The latter approach will be used for NPP projects to be built after year 2000. The main new feature of AS-92 is the addition of passive safety systems to the active ones in order to protect the fuel from damage.

  19. Experience of CR and RCCA operation in Ukrainian WWER-1000: Aspects of reliability, safety and economic efficiency

    International Nuclear Information System (INIS)

    Afanasyev, A.

    2000-01-01

    The next topics are represented in the paper: A brief history of WWER-1000 control rod (CR) and WWER-1000 rod cluster control assembly (RCCA) design; Evolution of WWER-1000 CR manufacturing technology and design; Experience of RCCA operation; Lifetime extension of WWER-1000 boron carbide CR; WWER-1000 reactor core operation problems due to partial RCCA insertion; Designing and licensing procedures and first operational experience of WWER-1000 RCCA (CR) with a combined absorber 'boron carbide-hafnium' and a chromium-nickel alloy cladding. The main conclusions are: Fuel assembly (FA) bow is the main reason of partial RCCA insertion during reactor core operation. However, the use of the RCCA and its driver bar with increased dead load, alongside with other measures, allow to reduce the probability of incomplete RCCA insertion; The materials used in CRs of RCCA in existing reactor operating modes have been working reliably; The use of hafnium under an appropriate price policy can give certain economic advantages for the Ukrainian NPPs, however, additional research is needed in order to confirm the specific CR physical characteristics and reliability. (author)

  20. Analysis of the State of Steam Generator Tubes

    International Nuclear Information System (INIS)

    Bergunker, Olga

    2008-01-01

    The problem of safe operation of SG heat exchanging tubes, of both economical and effective control of their state is still important these days. Issues connected with peculiarities of methods of SG tubes inspection, automated analysis of the inspection results, tubes state analysis and development of algorithms of forecasting their state are considered in this report. The need for effective use of extensive data arrays on SG operation has led to the necessity of creating software tools for collection, storage and analysis of these data. The data-analytical system 'NPP Steam Generators' meant for data systematization and visualization as well as various types of analyses of data on eddy current inspection of WWER-440 and WWER-1000 SG tubes is presented in this report. The main possibilities of the data-analytical system (DAS), the code current state and prospects of its development are shown. The main fields of DAS application are considered and some results of its practical use are mentioned, namely, in the field of forecasting SG tubes state. (authors)

  1. WWER identification and analysis of dominant factors affecting the fuel failure rates in WWER-1000 units in Czech Republic, Bulgaria, Ukraine and Russia

    International Nuclear Information System (INIS)

    Evdokimov, I.; Likhanskii, V.; Afanasieva, E.; Kanukova, V.; Kozhakin, A.; Maslova, L.; Chernetskiy, M.; Zborovskii, V.; Sorokin, A.

    2015-01-01

    The paper reviews the major findings of the study in the frame of the “Zero Failure Rate” project for WWER. The study included analysis and systematization of available data on leaking fuel assemblies found in 2003 through 2014 in WWER-1000 nuclear units in Russia, Ukraine, Czech Republic and Bulgaria. The study was intended to be used in preparation of recommendations and elaboration of corrective measures for enhancement of reliability and decrease of the failure rates for the WWER-1000 fuel. One of the key areas in successful implementation of the industry ‘zero failure’ goal is a challenge of significant increase of inspections of WWER-1000 fuel assemblies. It may be reasonable (with account taken for international experience) to think of development of more effective equipment for prompt fuel inspections & repair in WWER-1000 spent fuel pool. Another challenge is the elaboration of unified fuel inspection guidelines to ensure that limited industry resources are spent in the most productive way. In the frame of this work it may be helpful to implement in practice the criteria for safe removal of defective fuel rods from the leaking FA under repair

  2. Designing a nuclear power plant with 1000 MW WWER-type units

    Energy Technology Data Exchange (ETDEWEB)

    Berkovich, V; Kaloshin, J; Tatarnikov, V; Shenderovich, A

    1977-06-01

    A brief description is presented of a WWER-1000 nuclear power plant also considering its environmental impact and the problem of core poisoning. The following indicators are graphically shown in relation to the reactor output: turbogenerator unit outputs, efficiency, specific capital costs and own costs of electric power generated by the Voronezh nuclear power plant. Also listed are the specific consumption of metal and concrete, specific equipment weight and the specific volume of the buildings of the main generating unit as well as the cross section thereof.

  3. Design optimization on structure of blowdown in CPR1000 steam generator

    International Nuclear Information System (INIS)

    Wang Guoxian; Ren Hongbing; Zuo Chaoping; Zhu Yong; Mo Shaojia

    2014-01-01

    The structure of blowdown in CPR1000 steam generator has been optimized by eliminating the blowdown pipe and tube lane blocking, drilling holes in the peripheral tube lane, which can improve the accessibility of the central tube lane and facilitate inspecting and lancing. This paper detailed compares and analyzes the thermal hydraulic characteristic before and after optimization using GENEPI code which a special software for SG thermal hydraulic analysis. The results showed that the thermal hydraulic characteristic of steam generator meets the design requirements compared with the original design. Structure optimization can improve lancing effects, although the change of flow field distribution above the tubesheet leads to increase the number of tube subjected to sludge deposit. The analysis results proved the feasibility of the optimization. (authors)

  4. Extended analysis of WWER-1000 Charpy test data

    International Nuclear Information System (INIS)

    Vodenicharov, St.; Kamenova, Tz.

    2001-01-01

    The aim of this work is to study the embrittlement rate of WWER-1000 RPV weld metal with high Ni content and to determine influence of neutron irradiation on partial energies of ductile crack initiation, stable and unstable crack propagation and post crack arrest. (author)

  5. Thermohydraulic model of WWER-1000 core

    International Nuclear Information System (INIS)

    Maroti, L.; Szabados, L.

    1987-11-01

    Safe and economic operation of the WWER-1000 type reactor requires more accurate calculation of the thermohydraulic processes than the one satisfactory for the 440 type cores. The high degree of accuracy is needed both for reactor physics calculations and for the determination of the operational safety limits of the core. The paper illustrates the most important differences between the 1000 and 440 type reactors and presents the main fields of the development work necessary to reach the required accuracy. A prediction for the capability of the computer programs after the proposed development is also given and some suggestions for the further improvement is outlined. (author) 7 refs

  6. Designing a nuclear power plant with 1000 MW WWER-type units

    International Nuclear Information System (INIS)

    Berkovich, V.; Kaloshin, J.; Tatarnikov, V.; Shenderovich, A.

    1977-01-01

    A brief description is presented of a WWER-1000 nuclear power plant also considering its environmental impact and the problem of core poisoning. The following indicators are graphically shown in relation to the reactor output: turbogenerator unit outputs, efficiency, specific capital costs and own costs of electric power generated by the Voronezh nuclear power plant. Also listed are the specific consumption of metal and concrete, specific equipment weight and the specific volume of the buildings of the main generating unit as well as the cross section thereof. (J.B.)

  7. Tachometric flowmeters for measuring circulation water parameters in steam generators of the NPPs running on pressurized water reactors

    International Nuclear Information System (INIS)

    Ageev, A.G.; Korolkov, B.M.; Nigmatulin, B.I.; Belov, V.I.; Vasileva, R.V.; Trubkin, N.I.

    1997-01-01

    Tachometric flowmeters used in steam generators for determining the velocity and direction of the flow have a limited service life owing to the use of corundum for the bearing assembly components. Various materials were investigated for the feasibility of using them as alternatives for replacing the corundum bearing and guide bushing under conditions close to the conditions in steam generators: 7 MPa, 260 degC. Good results were obtained with bearing assemblies fabricated from corrosion-resistant steel. Testing of the transducer design and optimization of the technique was accomplished in the course of testing steam generators of the WWER-1000 reactor at the Balakovskaya nuclear power plant. The velocity and direction of flow in the steam generator were measured within a wide range of unit power ratings up to the values corresponding to full power output. The service life of the transducers proved to be not less than 720 hours. The transducer parameters remained unchanged over the entire operation period. (M.D.)

  8. Modelling studies of horizontal steam generator PGV-1000 with Cathare

    Energy Technology Data Exchange (ETDEWEB)

    Karppinen, I. [VTT Energy, Espoo (Finland)

    1995-12-31

    To perform thermal-hydraulic studies applied to nuclear power plants equipped with VVER, a program of qualification and assessment of the CATHARE computer code is in progress at the Institute of Protection and Nuclear Safety (IPSN). In this paper studies of modelling horizontal steam generator of VVER-1000 with the CATHARE computer code are presented. Steady state results are compared with measured data from the fifth unit of Novovoronezh nuclear power plant. (orig.). 10 refs.

  9. Modelling studies of horizontal steam generator PGV-1000 with Cathare

    Energy Technology Data Exchange (ETDEWEB)

    Karppinen, I [VTT Energy, Espoo (Finland)

    1996-12-31

    To perform thermal-hydraulic studies applied to nuclear power plants equipped with VVER, a program of qualification and assessment of the CATHARE computer code is in progress at the Institute of Protection and Nuclear Safety (IPSN). In this paper studies of modelling horizontal steam generator of VVER-1000 with the CATHARE computer code are presented. Steady state results are compared with measured data from the fifth unit of Novovoronezh nuclear power plant. (orig.). 10 refs.

  10. Operational indices of WWER-1000 fuel assemblies and their improvements

    Energy Technology Data Exchange (ETDEWEB)

    Vasilchenko, I; Demin, E [Opytno-Konstruktorskoe Byuro Gidropress, Podol` sk (Russian Federation)

    1994-12-31

    The most general design features of WWER-1000 fuel assembly are discussed. The following advantages of design are stated as well as their operational confirmation and occurrences: (1) `packing` density (tight-lattice) of fuel rods within the fuel assemblies; (2) simple handling of fuel assemblies and its small vulnerability; (3) good conditions for coolant mixing; (4) protection of the absorber rods against coolant effect; (5) adaptability to manufacture that provides stable quality. The main operational indices gathered during a ten-year period (1982-1992) at 17 WWER-1000 units in Russia and Ukraine are outlined. Provisions for emergency protection reliability are described. Future directions to improve fuel economy and control rod operability are discussed. 1 fig.

  11. Operational indices of WWER-1000 fuel assemblies and their improvements

    International Nuclear Information System (INIS)

    Vasilchenko, I.; Demin, E.

    1994-01-01

    The most general design features of WWER-1000 fuel assembly are discussed. The following advantages of design are stated as well as their operational confirmation and occurrences: 1) 'packing' density (tight-lattice) of fuel rods within the fuel assemblies; 2) simple handling of fuel assemblies and its small vulnerability; 3) good conditions for coolant mixing; 4) protection of the absorber rods against coolant effect; 5) adaptability to manufacture that provides stable quality. The main operational indices gathered during a ten-year period (1982-1992) at 17 WWER-1000 units in Russia and Ukraine are outlined. Provisions for emergency protection reliability are described. Future directions to improve fuel economy and control rod operability are discussed. 1 fig

  12. Testing of acoustic emission method during pressure tests of WWER-440 steam generators and pressurizers

    International Nuclear Information System (INIS)

    Wuerfl, K.; Crha, J.

    1987-01-01

    The results are discussed of measuring acoustic emission in output pressure testing of steam generators and pressurizers for WWER-440 reactors. The objective of the measurements was to test the reproducibility of measurements and to find the criterion which would be used in assessing the condition of the components during manufacture and in operation. The acoustic emission was measured using a single-channel Dunegan/Endevco apparatus and a 16-channel LOCAMAT system. The results showed that after the first assembly, during a repeat dismantle of the lids and during seal replacement, processes due to seal contacts and bolt and washer deformations were the main source of acoustic emission. A procedure was defined of how to exclude new acoustic emission sources in such cases. The acoustic emission method can be used for the diagnostics of plastic deformation processes or of crack production and propagation in components during service. (Z.M.)

  13. A facility for the testing and repair of primary collectors of steam generators at WWER nuclear power plants

    International Nuclear Information System (INIS)

    Herman, M.; Kuna, M.

    1990-01-01

    A facility labelled ZOKPG-1 has been developed for in-service inspection and repair of steam generator collectors in WWER-440 nuclear power plants. The facility makes possible visual, capillary, luminescence and ultrasonic inspection and eddy current testing of the internal surface, base material and welded joints of the collector. The repair modules of the ZOKPG-1 manipulator enable electroerosive elimination of surface defects of the material and local electrochemical decontamination of the internal surfaces. The manipulator can be operated at temperatures up to 40 degC, humidity up to 100%, and in conditions of radiation load up to 15 mGy/h and of surface contamination on the order of 100 Bq/cm 2 . (Z.M.). 16 figs

  14. WWER-1000 nuclear fuel manufacturing process at PJSC MSZ

    International Nuclear Information System (INIS)

    Morylev, A.; Bagdatyeva, E.; Aksenov, P.

    2015-01-01

    In this report a brief description of WWER-1000 fuel manufacturing process steps at PJSC MSZ as: uranium dioxide powder fabrication; fuel pellet manufacture fuel rod manufacture working assembly and fuel assembly manufacture is given. The implemented innovations are also presented

  15. Draft report of a consultants meeting on core control and protection strategy of WWER-1000 reactors. Extrabudgetary programme on the safety of WWER-1000 NPPs

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-07

    At the consultants' meeting on the 'Safety of WWER-1000 Model 320 Nuclear Power Plants' organized by the IAEA within the framework of its Extrabudgetary Programme on the Safety of WWER-1000 NPPs, which was held in Vienna, 1-5 June 1992, the problem of core control and protection strategy was identified as an issue of safety concern. Considering the safety importance of this issue, a consultants' meeting on 'Core Control and Protection Strategy for WWER-1000 Reactors' was convened in Vienna in April 1994 attended by 20 international experts in the area of core control and protection in order to review control and protection system design, to compare them with western practices and to recommend corrective measures. The first WWER-1000 NPP was put into operation in 1980 and there are currently 19 units operating. The accumulated operational experience is more than 130 reactor-years. In addition, there are 8 units under various stages of construction. The previous general observations in the area of core control and protection strategy was focused on core design objectives, core design and fuel management, fuel assembly and core component designs, including burnable absorber and control rod designs, core power distribution control strategy, core control and protection system designs and in-core and ex-core instrumentation systems. While core design objectives of WWER-1000 plants are similar to western practices in general, there are important differences on the design limits and regulatory practices followed for the compliance with the design limits. As a result of previous general observations and specific concerns on core control and protection system design, three working groups were formed to further investigate the specific issues and to compile information on safety issues based on design differences between these plants and similar western plants, to identify areas which need further analysis and make recommendations for short-term and long-term corrective

  16. Draft report of a consultants meeting on core control and protection strategy of WWER-1000 reactors. Extrabudgetary programme on the safety of WWER-1000 NPPs

    International Nuclear Information System (INIS)

    1994-01-01

    At the consultants' meeting on the 'Safety of WWER-1000 Model 320 Nuclear Power Plants' organized by the IAEA within the framework of its Extrabudgetary Programme on the Safety of WWER-1000 NPPs, which was held in Vienna, 1-5 June 1992, the problem of core control and protection strategy was identified as an issue of safety concern. Considering the safety importance of this issue, a consultants' meeting on 'Core Control and Protection Strategy for WWER-1000 Reactors' was convened in Vienna in April 1994 attended by 20 international experts in the area of core control and protection in order to review control and protection system design, to compare them with western practices and to recommend corrective measures. The first WWER-1000 NPP was put into operation in 1980 and there are currently 19 units operating. The accumulated operational experience is more than 130 reactor-years. In addition, there are 8 units under various stages of construction. The previous general observations in the area of core control and protection strategy was focused on core design objectives, core design and fuel management, fuel assembly and core component designs, including burnable absorber and control rod designs, core power distribution control strategy, core control and protection system designs and in-core and ex-core instrumentation systems. While core design objectives of WWER-1000 plants are similar to western practices in general, there are important differences on the design limits and regulatory practices followed for the compliance with the design limits. As a result of previous general observations and specific concerns on core control and protection system design, three working groups were formed to further investigate the specific issues and to compile information on safety issues based on design differences between these plants and similar western plants, to identify areas which need further analysis and make recommendations for short-term and long-term corrective

  17. Cleaning of OPR1000 Steam Generator by Ultrasonic Cavitation in Water

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Wootae [Korea Hydro and Nuclear Power Co., Ltd, Daejeon (Korea, Republic of); Kim, Sangtae; Yoon, Sangjung; Choi, Yongseok [Saean Engineering Corporation, Seoul (Korea, Republic of)

    2013-05-15

    Magnetic wheels are attached to the transducers to prevent tube damage which may be caused by wear between the transducers and SG tubes. To remove heat generated by transducers, we used water to water heat exchanger. Sludge removed from tube sheet area of the steam generator was pumped to filtering station for removing impurities in it. We designed an ultrasonic cleaning system for application to OPR1000 S/G. The technology was developed for removing sludge in OPR1000 S/G. However, the technology could easily be applied to other types of S/Gs. For cleaning OPR1000 SG, we designed an ultrasonic cleaning system with 12 transducers, 15 generators, a WRS, and a water treatment system. An experiment with a single transducer and the full scale OPR1000 S/G mock-up did not show very satisfactory result in ultrasound energy level. However, we expect sufficient effects if we apply 12 or more transducers in this case considering our previous experimental results as shown in the references. The ultrasonic cleaning system will be ready in August this year for performance test. After several experiments and the experiments followed, we are planning to apply this cleaning system for removing sludge in Korean OPR1000 S/Gs.

  18. Automated analysis technique developed for detection of ODSCC on the tubes of OPR1000 steam generator

    International Nuclear Information System (INIS)

    Kim, In Chul; Nam, Min Woo

    2013-01-01

    A steam generator (SG) tube is an important component of a nuclear power plant (NPP). It works as a pressure boundary between the primary and secondary systems. The integrity of a SG tube can be assessed by an eddy current test every outage. The eddy current technique(adopting a bobbin probe) is currently the main technique used to assess the integrity of the tubing of a steam generator. An eddy current signal analyst for steam generator tubes continuously analyzes data over a given period of time. However, there are possibilities that the analyst conducting the test may get tired and cause mistakes, such as: missing indications or not being able to separate a true defect signal from one that is more complicated. This error could lead to confusion and an improper interpretation of the signal analysis. In order to avoid these possibilities, many countries of opted for automated analyses. Axial ODSCC (outside diameter stress corrosion cracking) defects on the tubes of OPR1000 steam generators have been found on the tube that are in contract with tube support plates. In this study, automated analysis software called CDS (computer data screening) made by Zetec was used. This paper will discuss the results of introducing an automated analysis system for an axial ODSCC on the tubes of an OPR1000 steam generator.

  19. HEXTRAN-SMABRE calculation of the 6th AER Benchmark, main steam line break in a WWER-440 NPP

    International Nuclear Information System (INIS)

    Haemaelaeinen, A.; Kyrki-Rajamaeki, R.

    2003-01-01

    The sixth AER benchmark is the second AER benchmark for couplings of the thermal hydraulic codes and three dimensional neutron kinetic core models. It concerns a double end break of one main steam line in a WWER-440 plant. The core is at the end of its first cycle in full power conditions. In VTT HEXTRAN2.9 is used for the core kinetics and dynamics and SMABRE4.8 as a thermal hydraulic model for the primary and secondary loop. The plant model for SMABRE consists mainly of two input models, Loviisa model and a standard WWER-440/213 plant model. The primary loop includes six separate loops, the pressure vessel is divided into six parallel channels in SMABRE and the whole core calculation is performed in the core with HEXTRAN. The horizontal steam generators are modelled with heat transfer tubes in five levels and vertically with two parts, riser and downcomer. With this kind of detailed modelling of steam generators there occurs strong flashing after break opening. As a sequence of the main steam line break at nominal power level, the reactor trip is followed quite soon. The liquid temperature continues to decrease in one core inlet sector which may lead to recriticality and neuron power increase. The situation is very sensitive to small changes in the steam generator and break flow modelling and therefore several sensitivity calculations have been done. Also two stucked control rods have been assumed. Due to boric acid concentration in the high pressure safety injection subcriticality is finally guaranteed in the transient (Authors)

  20. Solution of the 'MIDICORE' WWER-1000 core periphery power distribution benchmark by KARATE and MCNP

    International Nuclear Information System (INIS)

    Temesvari, E.; Hegyi, G.; Hordosy, G.; Maraczy, C.

    2011-01-01

    The 'MIDICORE' WWER-1000 core periphery power distribution benchmark was proposed by Mr. Mikolas on the twentieth Symposium of AER in Finland in 2010. This MIDICORE benchmark is a two-dimensional calculation benchmark based on the WWER-1000 reactor core cold state geometry with taking into account the geometry of explicit radial reflector. The main task of the benchmark is to test the pin by pin power distribution in selected fuel assemblies at the periphery of the WWER-1000 core. In this paper we present our results (k eff , integral fission power) calculated by MCNP and the KARATE code system in KFKI-AEKI and the comparison to the preliminary reference Monte Carlo calculation results made by NRI, Rez. (Authors)

  1. Verification of 3-D generation code package for neutronic calculations of WWERs

    International Nuclear Information System (INIS)

    Sidorenko, V.D.; Aleshin, S.S.; Bolobov, P.A.; Bolshagin, S.N.; Lazarenko, A.P.; Markov, A.V.; Morozov, V.V.; Syslov, A.A.; Tsvetkov, V.M.

    2000-01-01

    Materials on verification of the 3 -d generation code package for WWERs neutronic calculations are presented. The package includes: - spectral code TVS-M; - 2-D fine mesh diffusion code PERMAK-A for 4- or 6-group calculation of WWER core burnup; - 3-D coarse mesh diffusion code BIPR-7A for 2-group calculations of quasi-stationary WWERs regimes. The materials include both TVS-M verification data and verification data on PERMAK-A and BIPR-7A codes using constant libraries generated with TVS-M. All materials are related to the fuel without Gd. TVS-M verification materials include results of comparison both with benchmark calculations obtained by other codes and with experiments carried out at ZR-6 critical facility. PERMAK-A verification materials contain results of comparison with TVS-M calculations and with ZR-6 experiments. BIPR-7A materials include comparison with operation data for Dukovany-2 and Loviisa-1 NPPs (WWER-440) and for Balakovo NPP Unit 4 (WWER-1000). The verification materials demonstrate rather good accuracy of calculations obtained with the use of code package of the 3 -d generation. (Authors)

  2. Horizontal steam generator thermal-hydraulics

    Energy Technology Data Exchange (ETDEWEB)

    Ubra, O. [SKODA Praha Company, Prague (Czechoslovakia); Doubek, M. [Czech Technical Univ., Prague (Czechoslovakia)

    1995-09-01

    Horizontal steam generators are typical components of nuclear power plants with pressure water reactor type VVER. Thermal-hydraulic behavior of horizontal steam generators is very different from the vertical U-tube steam generator, which has been extensively studied for several years. To contribute to the understanding of the horizontal steam generator thermal-hydraulics a computer program for 3-D steady state analysis of the PGV-1000 steam generator has been developed. By means of this computer program, a detailed thermal-hydraulic and thermodynamic study of the horizontal steam generator PGV-1000 has been carried out and a set of important steam generator characteristics has been obtained. The 3-D distribution of the void fraction and 3-D level profile as functions of load and secondary side pressure have been investigated and secondary side volumes and masses as functions of load and pressure have been evaluated. Some of the interesting results of calculations are presented in the paper.

  3. Neutron physics calculation for WWER-1000 absorber element lifetime determination

    International Nuclear Information System (INIS)

    Kurakin, K.Yu.; Kushmanov, S.A.

    2009-01-01

    Absorber element with compound absorber has been operating in WWER-1000 power units since 1995. AE design meets operating organizations requirements for reliability, service life (to 10 years) and safety functions. Extension of AE service life up to 20 - 30 years by the complex of calculation and experimental work is an important problem of WWER new designs development. The paper deals with the issues related to calculation determination of main factors that influence AE service life limitation - neutron flux and fluence onto absorbing and structural materials during extended service life. (Authors)

  4. Calculation of temperature fields formed in induction annealing of closing welded joint of jacket of steam generator for WWER 440 type nuclear power plant using ICL 2960 computer

    International Nuclear Information System (INIS)

    Sajnar, P.; Fiala, J.

    1983-01-01

    The problems are discussed of the mathematical description and simulation of temperature fields in annealing the closing weld of the steam generator jacket of the WWER 440 nuclear power plant. The basic principles are given of induction annealing, the method of calculating temperature fields is indicated and the mathematical description is given of boundary conditions on the outer and inner surfaces of the steam generator jacket for the computation of temperature fields arising during annealing. Also described are the methods of determining the temperature of exposed parts of heat exchange tubes inside the steam generator and the technical possibilities are assessed of the annealing equipment from the point of view of its computer simulation. Five alternatives are given for the computation of temperature fields in the area around the weld for different boundary conditions. The values are given of maximum differences in the temperatures of the metal in the annealed part of the steam generator jacket which allow the assessment of individual computation variants, this mainly from the point of view of observing the course of annealing temperature in the required width of the annealed jacket of the steam generator along both sides of the closing weld. (B.S.)

  5. Response of the steam generator VVER 1000 to a steam line break

    International Nuclear Information System (INIS)

    Novotny, J.; Novotny, J. Jr.

    2003-01-01

    Dynamic effects of a steam line break in the weld of the steam pipe and the steam collector on the steam generator system are analyzed. Modelling of a steam line break may concern two cases. The steam line without a restraint and the steam line protected by a whip restraint with viscous elements applied at the postulated break cross-section. The second case is considered. Programme SYSTUS offers a special element the stiffness and viscous damping coefficients of which may be defined as dependent on the relative displacement and velocity of its nodes respectively. A circumferential crack is simulated by a sudden decrease of longitudinal and lateral stiffness coefficients of these special SYSTUS elements to zero. The computation has shown that one can simulate the pipe to behave like completely broken during a time interval of 0,0001 s or less. These elements are used to model the whip restraint with viscous elements and viscous dampers of the GERB type as well. In the case of a whip restraint model the stiffness coefficient-displacement relation and damping coefficient - velocity relation are chosen to fit the given characteristics of the restraint. The special SYSTUS elements are used to constitute Maxwell elements modelling the elasto-plastic and viscous properties of the GERB dampers applied to the steam generator. It has been ascertained that a steam line break at the postulated weld crack between the steam pipe and the steam generator collector cannot endanger the integrity of the system even in a case of the absence of a whip restraint effect. (author)

  6. Accidents during shutdown conditions for NPP with WWER-1000/428

    International Nuclear Information System (INIS)

    Antropov, H.A.

    1996-01-01

    This paper considers the effect of such internal initiating events upon safety of the NPP with WWER-1000/428 as boron dilution and loss of residual heat removal at the reduced coolant inventory in the primary circuit. 2 refs

  7. Modeling of soluble impurities distribution in the steam generator secondary water

    International Nuclear Information System (INIS)

    Matal, O.; Simo, T.; Kucak, L.; Urban, F.

    1997-01-01

    A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.)

  8. Study of accelerated unit unloading mode initiated by turbine feed pump trip with TVSA fuel assemblies operation in WWER-1000

    International Nuclear Information System (INIS)

    Borysenko, V.I.; Kadenko, I.N.; Samoilenko, D.V.

    2012-01-01

    This paper provides the study results of accelerated unit unloading mode (AUU) initiated at WWER-1000 unit operated at 100 % power and its expediency in the event of single Turbo Feed Pump (TFP) failure. Modeling was performed using an advanced calculation code RELAP/SCDAPSIM/Mod3.4 and relevant model for KhNPP Unit No. 2. As the study shows, SCRAM cannot be prevented in case of failure of 3 main circulation pumps due to steam generators (SG) level drop. Based on the results obtained, it is reasonably justified to allow SCRAM signal instead of AUU activation in case of single TFP failure at power level more than 90 % of N n om. This will provide more sparing temperature modes for fuel assemblies and equipment, as well as prevent additional thermal cycling loads and violation of safe operation limits as SG water levels

  9. Status and trends in nuclear technology for power plants with WWER-1000 reactors. Review

    Energy Technology Data Exchange (ETDEWEB)

    Zorev, N N

    1977-04-01

    The problems of improving quality of nuclear equipment for WWER-1000 power plants and associated nuclear technology automation are surveyed. Examples of technological innovations are presented which significantly reduce labour intensity, time consumption and increase quality standards of the products. Some new automated equipments for materials welding, working, machining and quality control are described. The discussion is centering around heavy-section steel technologies. Some mechanical properties of new-developed nuclear grade steels designed for producing reactor vessels and steamgenerators, volume compensators and pipes, as well as steam separators and steamsuperheaters are also presented. Their properties (impact strength and radiation resistance) are pointed out to be superior to that of steels used abroad. The basic trend in nuclear structural material developments is towards integrated optimization of strength, performance and workability.

  10. Experimental studies of thermo-hydraulic processes during passive safety systems operation in new WWER NPP projects

    International Nuclear Information System (INIS)

    Morozov, A.V.; Remizov, O.V.; Kalyakin, D.S.

    2014-01-01

    The results of experimental study of thermal-hydraulic processes during operation of the passive safety systems of WWER reactors of new generation are given. The interaction processes of counter flows of saturated steam and cold water in vertical steam-line of the auxiliary passive core reflood system from secondary hydraulic accumulator are studied. The peculiarities of undeveloped boiling on single horizontal tube heating by steam and steam-gas mixture, which is character for WWER steam generator condensing mode, are investigated [ru

  11. Determination of fast neutron fluence at WWER-1000 pressure vessel

    International Nuclear Information System (INIS)

    Valenta, V. et al.

    1989-01-01

    The influence function method is an effective tool making it possible, by means of tabulated values to rapidly perform three-dimensional calculations of fast neutron fluences for various reactor core loadings and for various nuclear power plant units. The procedure for determining the spatial dependence of the fast neutron fluences in a WWER-1000 pressure vessel is described. For this, the reactor core is divided into sufficiently fine volume elements within which the neutron source can be regarded as coordinate-independent. The influence functions point to a substantial role of sources lying at the reactor core periphery. In WWER-1000 reactors, only 1 or 2 rows of peripheral assemblies are important. The influence function method makes possible a rapid and easy determination of preconditions for the assessment of the residual lifetime of the pressure vessel based on the actual reactor core loadings. (Z.M.). 7 figs., 8 refs

  12. Control rod drive WWER 1000 – tuning of input parameters

    Directory of Open Access Journals (Sweden)

    Markov P.

    2007-10-01

    Full Text Available The article picks up on the contributions presented at the conferences Computational Mechanics 2005 and 2006, in which a calculational model of an upgraded control rod linear stepping drive for the reactors WWER 1000 (LKP-M/3 was described and results of analysis of dynamical response of its individual parts when moving up- and downwards were included. The contribution deals with the tuning of input parameters of the 3rd generation drive with the objective of reaching its running as smooth as possible so as to get a minimum wear of its parts as a result and hence to achieve maximum life-time.

  13. Modeling of soluble impurities distribution in the steam generator secondary water

    Energy Technology Data Exchange (ETDEWEB)

    Matal, O.; Simo, T. [Energovyzkum s.r.o., Brno (Switzerland); Kucak, L.; Urban, F. [Slovak Technical Univ., Bratislava (Slovakia)

    1997-12-31

    A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.). 2 refs.

  14. Modeling of soluble impurities distribution in the steam generator secondary water

    Energy Technology Data Exchange (ETDEWEB)

    Matal, O; Simo, T [Energovyzkum s.r.o., Brno (Switzerland); Kucak, L; Urban, F [Slovak Technical Univ., Bratislava (Slovakia)

    1998-12-31

    A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.). 2 refs.

  15. Systems required during and after an earthquake. Summary report. WWER-1000 nuclear power plants

    International Nuclear Information System (INIS)

    Monette, P.

    1995-01-01

    The scope of this document is to list the mechanical, instrumentation and electrical components required during and after earthquake, in order to achieve and maintain safe shutdown conditions of a WWER-1000 type nuclear power plant. The main objective pursued in establishing the systems and equipment list is to provide guidance for the design and implementation of the backfits which are necessary to increase seismic resistance of the components required after earthquake. The presented list is established on generic basis, i.e. it is applicable to any specific WWER-1000

  16. Evaluation of WWER-1000 vessel materials fracture toughness

    International Nuclear Information System (INIS)

    Grinik, Eh.U.; Revka, V.N.; Chirko, L.I.; Chajkovskij, Yu.V.

    2007-01-01

    The lifetime of WWER-1000-type reactor vessels is finally conditioned by the fracture toughness (crack growth resistance) of RPV materials. Up to now in line with the regulations the fracture toughness is characterized by the critical temperature of brittleness determined by the results of the Charpy specimen impact testing. Such approach is typical for all countries operating the water pressure reactors. However, regulatory approach is known from the western specialists not always to characterize adequately the crack growth resistance of the vessel materials and in some cases to underestimate their characteristics in the reference state that leads to unreasonably high conservatism. Excessive conservatism may lead to the invalid restrictions in the operating modes and the service life of the reactor vessel. Therefore there appeared the necessity to apply another approaches based on the state-of-the-art experimental methods of the fracture mechanics and allowing evaluating the fracture toughness parameters sufficiently. The paper presents the results of the comparison of the regulatory approach and the Master curve approach from the point of view of the adequate determination of the vessel material crack growth resistance parameters. Analysis of the experimental data of the surveillance specimens illustrated the potential possibility of applying the new statistical method for the WWER-1000- type reactor vessel lifetime extension

  17. Unique systems for inspection and repair of VVER steam generators

    International Nuclear Information System (INIS)

    Kovalyk, Adrian; Pilat, Peter; Jablonicky, Pavol

    2014-01-01

    During over 30 years, VUJE Trnava has developed a series of remote control manipulators for in-service inspection and maintenance of steam generator collectors. The manipulators have been widely used on WWER type reactors in Slovakia and abroad. Some of the manipulators for non-destructive testing are shown.

  18. Experience and prospects of WWER-1000 reactor spent fuel transport

    International Nuclear Information System (INIS)

    Kondratyev, A.N.; Yershov, V.N.; Kozlov, Yu.V.; Kosarev, Yu.A.; Ilyin, Yu.V.; Pavlov, M.S.

    1989-01-01

    The paper deals with the USSR experience in shipping the commercial WWER-1000 reactor spent fuel in TK-10 and TK-13 casks. The cask designs, their basic characteristics and the WWER-1000 spent fuel features are described. An example of calculational/experimental approach in the design of a basket (one of the most important components) for spent fuel assembly (SFA) accommodation in a cask is given. The main problems of future development works are presented in brief. A concept of development of nuclear power industry with the closed fuel cycle is assumed in the Soviet Union, hence the spent nuclear fuel is to be transported from NPPs to reprocessing plants. To transport WWER-1000 spent fuel, the casks of two types were developed. These are: a pilot TK-10 cask of 3t capacity in fuel; a commercial TK-13 cask of ∼6t capacity in fuel. The pilot TK-10 cask is thick-walled (360mm) cylindrical vessel manufactured of steel shells and a bottom welded to each other. The material of the body is carbon steel. There is a steel jacket on the outer side of the cask body and at 120 mm distance off the bottom. On its cylindrical part between the jacket and the body there are T-shaped circular ribs acting as shock-absorbers. The space between the jacket and the body is filled with ethylene glycol solution of 65 degree C crystallization temperature, which functions as a neutron shielding. The TK-10 cask coolant is water or air (nitrogen) at minor excess pressure resulted from FA heatup after the cask sealing

  19. WWER-1000 unit reliability problems from the point of view of the main supplier of technological equipment

    International Nuclear Information System (INIS)

    Bursa, V.; Holousova, M.; Turnik, S.

    1990-01-01

    At Skoda Works in Plzen, data from the period of construction of nuclear power plants are processed on an ICL DRS 300 computer. The database systems DBASE II and DATAFLEX are available for creating reliability information systems. The information system that is being developed for WWER-1000 units is tested at the WWER-440 units of the Dukovany and Mochovce nuclear power plants. Activities in the field of evaluation of structure reliability of WWER-1000 nuclear power plants are aimed at two major goals, viz., developing a methodology for testing the reliability of the whole unit and its subsystems, and performing reliability analysis and calculations of reliability indices of the secondary circuit of a WWER-1000 nuclear power plant. The reason for the latter concern is the fact that in 1984-1986, secondary circuits contributed 46% to failures of Czechoslovak WWER-440 nuclear power plants. According to existing analyses, the time fluctuations of reliability indices obey no rule that could be employed for inferring indices expected in steady-state operating conditions from indices established in the starting stage of operation. (Z.M.). 10 refs

  20. Perspective decisions of WWER nuclear fuel: Implementation at Russian NPPs

    International Nuclear Information System (INIS)

    Molchanov, V.

    2003-01-01

    The scientific and technical policy pursued by JSC TVEL has managed to create a new generation of fuel assembly design on the basis of solutions tested at various units of Russian NPPs - Kola NPP, Kalinin NPP, Unit 1, Balakovo NPP Unit 1. The requirements set for the new generation nuclear fuel for WWER are: 1) High fuel burnup - up to 70 MWxdays/kgU; 2) Extended operation cycle - up to 6 years; 3) Increase of uranium charge to the core; 4) Increased lateral stability - bow not more than 7 mm; 5) High level of operating reliability - fuel rod leakage not worse than 10-5 1/year; 6) Demountable fuel assembly design. Post-irradiation examination results of fuel assemblies discharged from WWER-1000 reactors demonstrate that fuel rods have substantial reserve in general characteristics including that of dealing with planned burnup. In order to meet the requirements, trials are started for: implementation of rigid skeleton (WWER-1000); fuel column length extension (WWER-1000 and WWER-440); increase of UO 2 charge (WWER-1000 and WWER-440); enhancing of operational reliability and demountable design. It is concluded that the Russian nuclear fuel for WWER-type reactors is competitive and enables the implementation of state-of-the-art cost effective fuel cycles

  1. Modernization of WWER-1000 radiation monitoring systems

    Energy Technology Data Exchange (ETDEWEB)

    Smith, T [General Atomics, San Diego, CA (United States)

    1996-12-31

    A modernization scheme of the radiation monitoring system for WWER-1000 is proposed. It has a purpose to comply with international standards and to reduce operational and maintenance cost by deleting obsolete components and reducing the number of detector channels. Detailed layouts of I/C system architecture, digital radiation monitoring system (DRAMS) architecture and LRP block diagram are presented. If planned and implemented properly, this program can provide cost savings by reducing time required to access and display data and maintenance cost by deleting obsolete parts and decreasing the number of detector channels. 3 figs.

  2. Modernization of WWER-1000 radiation monitoring systems

    International Nuclear Information System (INIS)

    Smith, T.

    1995-01-01

    A modernization scheme of the radiation monitoring system for WWER-1000 is proposed. It has a purpose to comply with international standards and to reduce operational and maintenance cost by deleting obsolete components and reducing the number of detector channels. Detailed layouts of I/C system architecture, digital radiation monitoring system (DRAMS) architecture and LRP block diagram are presented. If planned and implemented properly, this program can provide cost savings by reducing time required to access and display data and maintenance cost by deleting obsolete parts and decreasing the number of detector channels. 3 figs

  3. Innovation of blow-down system in steam generators of a VVER 440 unit

    International Nuclear Information System (INIS)

    Matal, O.; Simo, T.; Mancev, M.D.

    1997-01-01

    The impurities getting into the steam generator with the feedwater are continually removed by the blowdown and unit sludge system. The mostly non-symmetrical type of pipe branches under steam generators at WWER-440 units causes nonuniform blowdown flow rates at the halves of the steam generator; this often leads to a blocking of the pipe with the lower flow rate. The most simple way of hydraulically equalizing the blowdown pipes is to implement symmetric blowdown pipes and to install efficient throttling elements in the pipe. The proposed innovation will make it possible to re-distribute the blowdown flow rates and to reduce more effectively the concentrations of impurities in steam generators. (M.D.)

  4. A procedure for temperature-stress fields calculation of WWER-1000 primary circuit in PTS event

    Energy Technology Data Exchange (ETDEWEB)

    Petkov, G [Technical Univ., Dept. Thermal and Nuclear Power Engineering, Sofia (Bulgaria); Groudev, P; Argirov, J [Bulgarian Academy of Science, Inst. for Nuclear Research and Nuclear Energy, Sofia (Bulgaria)

    1997-09-01

    The paper presents the procedure of an investigation of WWER-1000 primary circuit temperature-stress field by the use of thermohydraulic computation data for a pressurized thermal shock event ``Core overcooling``. The procedure is based on a model of the plane stress state with ideal contact between wall and medium for the calculation. The computation data are calculated on the base of WWER-1000 thermohydraulic model by the RELAP5/MOD3 codes. This model was developed jointly by the Bulgarian and BNL/USA staff to provide an analytical tool for performing safety analysis. As a result of calculations by codes the computation data for temperature field law (linear laws of a few distinguished parts) and pressure of coolant at points on inner surface of WWER-1000 primary circuit equipment are received. Such calculations can be used as a base for determination of all-important load-carrying sections of the primary circuit pipes and vessels, which need further consideration. (author). 7 refs, 2 figs, 2 tabs.

  5. Experience running in and improvement of secondary circuit water chemistry of Kalinin NPP WWER-1000

    International Nuclear Information System (INIS)

    Noev, V.V.; Kukharev, N.D.; Otchenashev, G.D.; Guzeeva, G.I.; Kochetova, G.G.

    1991-01-01

    Basic characteristics of the secondary circuit water-chemical conditions at the Kalinin 1 and 2 reactors are presented. These are the WWER-1000 reactors with K-1000-1500 turbines. The analysis conducted makes it possible to conclude that all indicated values can meet the standards by introducing the hydrazine-ammonium regime in the secondary circuit with feedwater pH value equal to 9±0.2. Realization of design scheme for condensate-feeding circuit washing is necessary for acceleration of the water-chemical mode stabilization. Moreover the units should be equipped with automated chemical control instrumentation of a new generation

  6. Ammonia role in WWER primary circuit water chemistry optimization

    International Nuclear Information System (INIS)

    Kritskij, V.G.; Stjagkin, P.S.; Chvedova, M.N.; Slobodov, A.A.

    1999-01-01

    Ammonia influence on iron crud's solubility at 300 deg. C and different relations of boric acid and alkaline cation sum are considered. Reduction of dose rate on WWER-440 steam generators at average ammonia concentration increasing is empirically explained. Practical recommendations on optimization of WWER primary circuit water chemistry are given. (author)

  7. 'Kazmer' a complex noise diagnostic system for 1000 MWe PWR WWER type nuclear power units

    International Nuclear Information System (INIS)

    Por, G.

    1992-06-01

    Noise diagnostic systems have previously been developed and installed for the WWER-440 type reactors at the Paks Nuclear Power Plant, Hungary. Based on the experiences, the system has been extended and modified for use in 1000 MWe, WWER-1000 type units. KAZMER consists of three subsystem, the KARD reactor noise diagnostic system, ARGUS vibration monitoring system for rotation machinery, and ALMOS acoustic monitoring system. The installation of the KAZMER system at the Kalinin Nuclear Power Station, Russia, and the first operational experiences are outlined. (R.P.) 15 refs.; 9 figs

  8. Advanced fuel cycles of WWER-1000 reactors

    International Nuclear Information System (INIS)

    Lunin, G.; Novikov, A.; Pavlov, V.; Pavlovichev, A.

    2003-01-01

    The present paper considers characteristics of fuel cycles for the WWER-1000 reactor satisfying the following conditions: duration of the campaign at the nominal power is extended from 250 EFPD up to 470 and more ones; fuel enrichment does not exceed 5 wt.%; fuel assemblies maximum burnup does not exceed 55 MWd/kgHM. Along with uranium fuel, the use of mixed Uranium-Plutonium fuel is considered. Calculations were conducted by codes TVS-M, BIPR-7A and PERMAK-A developed in the RRC Kurchatov Institute, verified for the calculations of uranium fuel and certified by GAN RF

  9. Comparative Analyses on OPR1000 Steam Generator Tube Rupture Event Emergency Operational Guideline

    International Nuclear Information System (INIS)

    Lee, Sang Won; Bae, Yeon Kyoung; Kim, Hyeong Teak

    2006-01-01

    The Steam Generator Tube Rupture (SGTR) event is one of the important scenarios in respect to the radiation release to the environment. When the SGTR occurs, containment integrity is not effective because of the direct bypass of containment via the ruptured steam generator to the MSSV and MSADV. To prevent this path, the Emergency Operational Guideline of OPR1000 indicates the use of Turbine Bypass Valves (TBVs) as an effective means to depressurize the main steam line and prevent the lifting of MSSV. However, the TBVs are not operable when the offsite power is not available (LOOP). In this situation, the RCS cool-down is achieved by opening the both intact and ruptured SG MSADV. But this action causes the large amount of radiation release to the environment. To minimize the radiation release to the environment, KSNP EOG adopts the improved strategy when the SGTR concurrently with LOOP is occurred. However, these procedures show some duplicated procedure and branch line that might confusing the operator for optimal recovery action. So, in this paper, the comparative analysis on SGTR and SGTR with LOOP is performed and optimized procedure is proposed

  10. Safety provisions for steam generator in Mochovce nuclear power plant. BO CI 04 Integrity of primary collectors of VVER 440 steam generators

    International Nuclear Information System (INIS)

    Cikryt, F.; Bednarek, L.; Matocha, K.; Vejvoda, S.

    1997-01-01

    This paper dealt with the identification of possible damaging mechanism of the collector of the WWER 440 steam generator, cracking of primary collectors, corrosion damage of the protective coat of the primary collector circumferential weld, cracking of breathing space in the region of blinding effect by corrosion and strain, leaking of disassembling joint of the primary collector lid and with the integrity of heat exchanging tubes

  11. Development and validation of natural circulation based systems for new WWER designs

    International Nuclear Information System (INIS)

    Kurakov, Y.A.; Dragunov, Y.G.; Podshibiakin, A.K.; Fil, N.S.; Logvinov, S.A.; Sitnik, Y.K.; Berkovich, V.M.; Taranov, G.S.

    2002-01-01

    Elaboration and introduction of NPP designs with improved technical and economic parameters are defined as an important element of the National Program of nuclear power development approved by the Russian Federation Government in 1998. This Program considers the designs of WWER-1000/V-392 and WWER-640/ V-407 power units as the priority projects of the new generation NPPs with increased safety. A number of passive systems based on natural circulation phenomena are used in V-392 and V-407 designs to prevent or mitigate severe accidents. Design basis, configuration and effect of some naturally driven systems of V-392 design sited at Novovoronezh are mainly reflected in the present paper. One of the most important mean for severe accident prevention in V-392 design is so called SPOT - passive heat removal system designed to remove core decay heat in case of station blackout (including failure of all diesel generators). This system extracts the steam from the steam generator, condenses it and returns water to steam generator by natural circulation. The SPOT heat exchangers are cooled by atmospheric air coming by natural circulation through a special direct action control gates which operate passively as well. Extensive experimental investigation of the different aspects of this system operation has been carried out to validate its functioning under real plant conditions. In particular, full-scale section of air heat exchanger-condenser has been tested with natural circulation steam, condensate and air paths modeled. The environment air temperature and steam pressure condensing were varied in the wide range, and the relevant experimental results are being discussed in this paper. The effect of wind velocity and direction to the containment is also checked by the experiments. (author)

  12. Modelling horizontal steam generator with ATHLET. Verification of different nodalization schemes and implementation of verified constitutive equations

    Energy Technology Data Exchange (ETDEWEB)

    Beliaev, J.; Trunov, N.; Tschekin, I. [OKB Gidropress (Russian Federation); Luther, W. [GRS Garching (Germany); Spolitak, S. [RNC-KI (Russian Federation)

    1995-12-31

    Currently the ATHLET code is widely applied for modelling of several Power Plants of WWER type with horizontal steam generators. A main drawback of all these applications is the insufficient verification of the models for the steam generator. This paper presents the nodalization schemes for the secondary side of the steam generator, the results of stationary calculations, and preliminary comparisons to experimental data. The consideration of circulation in the water inventory of the secondary side is proved to be necessary. (orig.). 3 refs.

  13. Modelling horizontal steam generator with ATHLET. Verification of different nodalization schemes and implementation of verified constitutive equations

    Energy Technology Data Exchange (ETDEWEB)

    Beliaev, J; Trunov, N; Tschekin, I [OKB Gidropress (Russian Federation); Luther, W [GRS Garching (Germany); Spolitak, S [RNC-KI (Russian Federation)

    1996-12-31

    Currently the ATHLET code is widely applied for modelling of several Power Plants of WWER type with horizontal steam generators. A main drawback of all these applications is the insufficient verification of the models for the steam generator. This paper presents the nodalization schemes for the secondary side of the steam generator, the results of stationary calculations, and preliminary comparisons to experimental data. The consideration of circulation in the water inventory of the secondary side is proved to be necessary. (orig.). 3 refs.

  14. Determination of in-service change in the geometry of WWER-1000 core baffle: Calculations and measurements

    International Nuclear Information System (INIS)

    Margolin, B.Z.; Varovin, A.Y.; Minkin, A.J.; Sorokin, A.A.; Piminov, V.A.; Evdokimenko, V.V.; Fedosovsky, M.E.; Sherstobitov, A.E.; Ovchinnikov, A.G.; Pikulik, S.S.; Erak, D.Y.; Bobkov, A.V.; Timofeev, A.M.; Timokhin, V.I.; Yakushev, S.V.; Vasiliev, V.G.

    2015-01-01

    The paper gives the basic constitutive equations describing radiation swelling and creep depending on neutron dose, irradiation temperature and triaxial stress state, and justifies these equations experimentally. The WWER-1000 core baffle change in geometry was calculated by different models describing the effect of stresses on radiation swelling. The calculated results are compared with the measured ones for the operating WWER-1000 core baffle at the Balakovo NPP, Unit 1. A method of individual prediction of core baffle geometry change on the basis of the measurement results has been proposed. (authors)

  15. Determination of neutron fluence and radiation brittleness temperature of WWER-440 and WWER-1000 pressure vessels in Kozloduy NPP

    International Nuclear Information System (INIS)

    Ilieva, K.; Apostolov, T.; Belousov, S.; Petrova, T.; Antonov, S.; Ivanov, K.; Prodanova, R.

    1993-01-01

    In Units 1-4 of Kozloduy NPP (WWER-440/230), the weld 4 of RPV undergoes the most severe irradiation embrittlement. Neither witness-samples, nor detectors are designed for these reactors. Transport calculations of fast neutron fluence on WWER-440 RPV and ex-vessel measurements by threshold activation detectors are the primary means for adequate assessment of metal state and for prognosis concerning the reactor life span. In WWER-1000 reactors (Units 5-6) the maximum neutron fluence occurs on the weld 3. The systematical observation of metal state is performed through witness-samples and threshold activation detectors ( 54 Fe (n,p), 63 Cu (n,α), 93 Nb (n,n')) placed above the reactor top edge and at the first vessel ring level. There are big differences in energy spectrum and integral neutron flux falling onto the weld 3, the RPV base metal and the staff detectors. This requires additional neutron measurements in the air gap between the RPV and the thermal insulation. (author)

  16. Status and prospects of activities on algorithms and methods in WWER-1000 core control

    International Nuclear Information System (INIS)

    Filimonov, P.; Krainov, Y.; Proselkov, V.

    1994-01-01

    On the basis of long-term operational experience and investigations the problems of WWER-1000 reactor control are discussed. Such control is needed for WWER-1000, as well as for its Western analog PWR, for suppressing the axially instable power density field resulted from non-equilibrium redistribution of Xe-135 nuclei in the reactor core. It has been found that an adequate assessment of the reactor state and the prediction of its response to various control actions is essential for the control of power density distribution. For this purpose a computerized operator's adviser with a reactor simulator realizing a physical reactor model based on BIPR-7 code is used. The operation experience of WWER-1000 shows that the available control algorithms allow, with a fair degree of assurance, the prevention of intensive xenon oscillations and the stabilization of the axial offset. But in connection with the renunciation of half-length control rods a new algorithm is under development which makes use of full-length control rods for suppressing the intensive xenon oscillations in the descending phase. A new method based on BIPR-7 and PERMAK codes is also being developed for estimating the value and rate of linear power rating change of the fuel elements in power cycling. 12 figs., 7 refs

  17. Status and prospects of activities on algorithms and methods in WWER-1000 core control

    Energy Technology Data Exchange (ETDEWEB)

    Filimonov, P; Krainov, Y; Proselkov, V [Russian Research Centre Kurchatov Inst., Moscow (Russian Federation)

    1994-12-31

    On the basis of long-term operational experience and investigations the problems of WWER-1000 reactor control are discussed. Such control is needed for WWER-1000, as well as for its Western analog PWR, for suppressing the axially instable power density field resulted from non-equilibrium redistribution of Xe-135 nuclei in the reactor core. It has been found that an adequate assessment of the reactor state and the prediction of its response to various control actions is essential for the control of power density distribution. For this purpose a computerized operator`s adviser with a reactor simulator realizing a physical reactor model based on BIPR-7 code is used. The operation experience of WWER-1000 shows that the available control algorithms allow, with a fair degree of assurance, the prevention of intensive xenon oscillations and the stabilization of the axial offset. But in connection with the renunciation of half-length control rods a new algorithm is under development which makes use of full-length control rods for suppressing the intensive xenon oscillations in the descending phase. A new method based on BIPR-7 and PERMAK codes is also being developed for estimating the value and rate of linear power rating change of the fuel elements in power cycling. 12 figs., 7 refs.

  18. Structural capacity assessment of WWER-1000 MW reactor containment. Progress report

    International Nuclear Information System (INIS)

    Jordanov, M.

    1999-01-01

    The objective of the project is to provide assessment of the structural behaviour and safety capacity of the WWER-1000 MW Reactor Building Containment at Kozloduy NPP under critical combination of loads according to the current international requirements. The analysis is focused on a realistic assessment of the Containment taking into account the non-linear shell behaviour of the pre-stressed reinforced concrete structure. Previous assessments of the status of pre stressing cables pointed out that the efficiency of the Containment as a final defence barrier for internal and external events depends on their reliability. Due to this, the experimental data obtained from embedded sensors (gauges) at pre-stressed shell structure is to be compared with the results from analytical investigations. The reliability of the WWER-1000 MW accident prevention system is under evaluation in the project. The Soviet standard design WWER-1000 MW type units installed in Kozloduy NPP were originally designed for a Safe Shutdown Earthquake (SSE) with a peak ground acceleration (PGA) of 0.1g. The new site seismicity studies revealed that the seismic hazard for the site significantly exceeds the originally estimated and a Review Level Earthquake (RLE) anchored to PGA=0.20g was proposed for re-assessment of the structures and equipment at Kozloduy NPP. The scope of the study is a re-assessment of the Containment structure under critical combination of loads according to the current safety and reliability requirements, including comparison between the Russian design requirements and the international regulations. Additionally, an investigation of the pre-stressing technology and the annual control of the cables' pre-stressing of the Containment is to be made. The crane influence on the dynamic behaviour of the Containment will be done as well as a study of the integrity of the Containment as a final defence barrier

  19. Vibrodynamical tests of RP equipment with application of imitation area of WWER-1000 reactor

    International Nuclear Information System (INIS)

    Khajretdinov, V.U.; Tarkhanov, V.V.; Rodionova, I.N.

    2015-01-01

    Performance of preoperational tests and measurements with application of imitation area of the reactor is a distinctive characteristic of putting into operation of NPP Units with WWER-1000/1200. The imitation area consists of 163 full-scale FA models, where fuel matrixes made of nuclear-fissionable material, are replaced by leaden simulators. Vibrodynamic tests involve inspection of hydrodynamic disturbances in the primary circuit (dynamic impact on the inspected elements), characteristics of vibration response of the main equipment stress-deformed state of bearing structure, and also parameters of moving and geometry of the inspected objects (boundary conditions at process simulation). Preoperational tests and measurements on the simulated area of WWER-1000/1200 are obligatory and performed at every unit of NPP of this type [ru

  20. Stainless steel corrosion in conditions simulating WWER-1000 primary coolant. Corrosion behaviour in mixed core

    International Nuclear Information System (INIS)

    Krasnorutskij, V.S.; Petel'guzov, I.A.; Gritsina, V.M.; Zuek, V.A.; Tret'yakov, M.V.; Rud', R.A.; Svichkar', N.V.; Slabospitskaya, E.A.; Ishchenko, N.I.

    2011-01-01

    Research into corrosion kinetics of austenitic stainless steels (06Cr18Ni10Ti, 08Cr18Ni10Ti, 12Cr18Ni10Ti) in medium which corresponds to composition and parameters of WWER-1000 primary coolant with different pH values in autoclave out-pile conditions during 14000 hours is given. Surface of oxide films on stainless steels is investigated. Visual inspection of Westinghouse and TVEL fuel was carried out after 4 cycles in WWER-1000 primary water chemistry conditions at South Ukraine NPP. Westinghouse and TVEL fuel cladding materials possess high corrosion resistance. Blushing of weldments was observed. No visual corrosion defects or deposits were observed on fuel rods.

  1. Consistent Code Qualification Process and Application to WWER-1000 NPP

    International Nuclear Information System (INIS)

    Berthon, A.; Petruzzi, A.; Giannotti, W.; D'Auria, F.; Reventos, F.

    2006-01-01

    Calculation analysis by application of the system codes are performed to evaluate the NPP or the facility behavior during a postulated transient or to evaluate the code capability. The calculation analysis constitutes a process that involves the code itself, the data of the reference plant, the data about the transient, the nodalization, and the user. All these elements affect one each other and affect the results. A major issue in the use of mathematical model is constituted by the model capability to reproduce the plant or facility behavior under steady state and transient conditions. These aspects constitute two main checks that must be satisfied during the qualification process. The first of them is related to the realization of a scheme of the reference plant; the second one is related to the capability to reproduce the transient behavior. The aim of this paper is to describe the UMAE (Uncertainty Method based on Accuracy Extrapolation) methodology developed at University of Pisa for qualifying a nodalization and analysing the calculated results and to perform the uncertainty evaluation of the system code by the CIAU code (Code with the capability of Internal Assessment of Uncertainty). The activity consists with the re-analysis of the Experiment BL-44 (SBLOCA) performed in the LOBI facility and the analysis of a Kv-scaling calculation of the WWER-1000 NPP nodalization taking as reference the test BL-44. Relap5/Mod3.3 has been used as thermal-hydraulic system code and the standard procedure adopted at University of Pisa has been applied to show the capability of the code to predict the significant aspects of the transient and to obtain a qualified nodalization of the WWER-1000 through a systematic qualitative and quantitative accuracy evaluation. The qualitative accuracy evaluation is based on the selection of Relevant Thermal-hydraulic Aspects (RTAs) and is a prerequisite to the application of the Fast Fourier Transform Based Method (FFTBM) which quantifies

  2. Electroerosion cutting of low-sized templets from WWER-1000 type reactor vessel

    International Nuclear Information System (INIS)

    Neklyudov, I.M.; Ozhigov, L.S.; Gozhenko, S.V.

    2012-01-01

    The article presents the results of developed method of electroerosion cutting of low-sized templets for the reactor vessel metal composition and structure control in laboratory environment. The article describes the equipment for the remote electroerosive cutting of templets from WWER-1000 type reactor vessel by rigid electrode. The testing results are also shown.

  3. The FARC fuel archive of WWER

    International Nuclear Information System (INIS)

    Zizin, M.N.; Parfenova, N.A.; Proselkov, V.N.; Shishkov, L.K.

    1998-01-01

    The principles of organisation are explained and the structure of the FARC fuel archive for WWER reactors is circumscribed. The objective of archive is accumulation of fuel data, data storage and obtaining of fuel using characteristics. The working version of fuel archive on 01 July 1998 is realised, in which the data tables for fuel assemblies for 169 WWER-440 cycles and 35 WWER-1000 cycles are stored. There are two different versions of fuel archive - for WWER-440 (FARC) and for WWER-1000 (FARC1000). A structure of some tables and the texts of programs for them differ. (Authors)

  4. Determination and elimination of the reasons for increased control rod insertion time of the Kozloduy NPP WWER-1000

    International Nuclear Information System (INIS)

    Nikolov, K.

    1996-01-01

    The emergency insertion speed of the control rod upon reactor shutdown is of crucial importance for reactor safety. The designed insertion time for WWER-1000 reactors should be in the limits 1,5 to 4 s. Having in mind some data about increased insertion times of WWER-1000 type reactors in Russia and Ukraine, a practice of measuring this parameters during each planned outage of the Kozloduy NPP Unit 6 is introduced. Some technical improvements of the fuel assembly are made in order to reach the nominal parameters of the unit

  5. Water chemistry in WWER reactors

    International Nuclear Information System (INIS)

    Yurmanov, V.A.; Mamet, V.A.; Shestakov, Yu.M.; Amosov, M.M.

    1997-01-01

    In this paper ''Water Chemistry in WWER Reactors'', are briefly described the 30 WWERs in Russian and the Ukraine, and are pointed out the essential differences between the 440s and 1000s. The primary coolant in the six loops of the former type operates at 270-290 deg. C, while the four loops of the latter type are at 290-320 deg. C. Performance of the fuel has been generally good with some fission product activities emanating from tramp uranium. Incidents causing unusually high fission product levels were overheating of the 16th fuel load at Kola NPP in 1990 by a reduced coolant flow, and fuel defects at Novovoronezh NPP resulting from deposits of carbon and corrosion products. Organic carbon, depositing from the coolant in regions of high turbulence (i.e. at the spacer grids), provokes corrosion product deposition. The source of the organic is not known. New chemistry guidelines have been implemented since 1992-93 for Russian and Ukrainian WWERs. These include higher pH T values (7.0-7.1 as opposed to 6.6-6.9) and tighter controls on oxygen and impurities. Lower dose rates in steam generator channels are reported. Significant reduction in operator doses are achieved by these methods coupled with a ''soft decontamination'' involving changing the KOH concentration and, hence, the pH T before shutdown. The benefits of hydrazine treatment for deoxygenating feedwater and coolant prior to start up, for injecting before shutdown and for general chemistry control on radiation fields are described. (author). 7 refs, 9 figs, 8 tabs

  6. Water chemistry in WWER reactors

    Energy Technology Data Exchange (ETDEWEB)

    Yurmanov, V A; Mamet, V A; Shestakov, Yu M; Amosov, M M [All-Russian Scientific Research Inst. for Nuclear Power Plants Operation, Moscow (Russian Federation)

    1997-02-01

    In this paper ``Water Chemistry in WWER Reactors``, are briefly described the 30 WWERs in Russian and the Ukraine, and are pointed out the essential differences between the 440s and 1000s. The primary coolant in the six loops of the former type operates at 270-290 deg. C, while the four loops of the latter type are at 290-320 deg. C. Performance of the fuel has been generally good with some fission product activities emanating from tramp uranium. Incidents causing unusually high fission product levels were overheating of the 16th fuel load at Kola NPP in 1990 by a reduced coolant flow, and fuel defects at Novovoronezh NPP resulting from deposits of carbon and corrosion products. Organic carbon, depositing from the coolant in regions of high turbulence (i.e. at the spacer grids), provokes corrosion product deposition. The source of the organic is not known. New chemistry guidelines have been implemented since 1992-93 for Russian and Ukrainian WWERs. These include higher pH{sub T} values (7.0-7.1 as opposed to 6.6-6.9) and tighter controls on oxygen and impurities. Lower dose rates in steam generator channels are reported. Significant reduction in operator doses are achieved by these methods coupled with a ``soft decontamination`` involving changing the KOH concentration and, hence, the pH{sub T} before shutdown. The benefits of hydrazine treatment for deoxygenating feedwater and coolant prior to start up, for injecting before shutdown and for general chemistry control on radiation fields are described. (author). 7 refs, 9 figs, 8 tabs.

  7. Fuel cycles of WWER-1000 based on assemblies with increased fuel mass

    International Nuclear Information System (INIS)

    Kosourov, E.; Pavlovichev, A.; Shcherenko, A.

    2011-01-01

    Modern WWER-1000 fuel cycles are based on FAs with the fuel column height of 3680 mm, diameters of the fuel pellet and its central hole of 7.6 and 1.2 mm respectively. The highest possible fuel enrichment has reached its license limit that is 4.95 %. Research in the field of modernization, safety justification and licensing of equipment for fuel manufacture, storage and transportation are required for further fuel enrichment increase (above 5 %). So in the nearest future an improvement of technical and economic characteristics of fuel cycles is possible if assembly fuel mass is increased. The available technology of the cladding thinning makes it possible. If the fuel rod outer diameter is constant and the clad inner diameter is increased to 7.93 mm, the diameter of the fuel pellet can be increased to 7.8 mm. So the suppression of the pellet central hole allows increasing assembly fuel weight by about 8 %. In this paper we analyze how technical and economic characteristics of WWER-1000 fuel cycle change when an advanced FA is applied instead of standard one. Comparison is made between FAs with equal time interval between refueling. This method of comparison makes it possible to eliminate the parameters that constitute the operation component of electricity generation cost, taking into account only the following technical and economic characteristics: 1)cycle length; 2) average burnup of spent FAs; 3) specific natural uranium consumption; 4)specific quantity of separative work units; 5) specific enriched uranium consumption; 6) specific assembly consumption. Collected data allow estimating the efficiency of assembly fuel weight increase and verifying fuel cycle characteristics that may be obtained in the advanced FAs. (authors)

  8. Steam turbines for nuclear power plants

    International Nuclear Information System (INIS)

    Stastny, M.

    1983-01-01

    A three-cylinder 220 MW saturated steam turbine was developed for WWER reactors by the Skoda concern. Twenty four of these turbines are currently in operation, in production or have been ordered. A 1000 MW four-cylinder turbine is being developed. The disign of the turbines has had to overcome difficulties connected with the unfavourable effects of wet steam at extreme power values. Great attention had to be devoted to the aerodynamics of control valves and to the prevention of flow separation areas. The problem of corrosion-erosion in guide wheels and the high pressure section was resolved by the use of ferritic stainless steels. For the low pressure section it was necessary to separate the moisture and to reheat the steam in the separator-reheater. Difficulties caused by the generation of wet steam in the low pressure section by spontaneous condensation were removed. Also limited was the erosion caused by droplets resulting from the disintegration of water films on the trailing edges. (A.K.)

  9. Safety issues and their ranking for 'small series' WWER-1000 nuclear power plants. A publication of the extrabudgetary programme on the safety of WWER and RBMK nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-09-01

    This report presents the safety issues in 'small series' WWER-1000 nuclear power plants (NPPs). Safety issues are deviations from current recognized safety practices in design and operation judged to be safety significant by their impact on the plants' defence in depth. This report is intended to serve as reference for the development of plant specific safety improvement programmes and for the evaluation of measures proposed and/or implemented. The identification of safety issues is based on safety studies conducted by the operators of 'small series' WWER-1000 units and by organizations dealing with these reactors, on findings of IAEA safety missions to 'small series' WWER-1000 plants in South Ukraine, at Novovoronezh and Kalinin, and on information obtained from specialists from various countries during an IAEA consultants meeting, 8-12 September 1997 in Vienna, within the framework of the Extra budgetary Programme on the Safety of WWER and RBMK NPPs. Safety issues are first presented according to their impact on the main safety functions and are then described individually. The safety issues are characterized by issue title and specified by issue clarification. Safety issues connected with plant design are followed by the ranking of the issue and ranking justification. Altogether 85 safety issues have been identified, 12 of which are in Category III (defence in depth is insufficient, immediate corrective action is necessary), 38 in Category 11 (defence in depth is degraded, action is needed to resolve the issue) and 22 in Category I (departure from international practices, to be addressed as part of actions to resolve higher priority issues). In the case of operational safety issues (13 safety issues) no ranking is provided as the available material was considered insufficient. For each safety issue, comments and recommendations are made by the IAEA; the status of corresponding measures to improve safety implemented or planned at each site are presented in the

  10. Safety issues and their ranking for 'small series' WWER-1000 nuclear power plants. A publication of the extrabudgetary programme on the safety of WWER and RBMK nuclear power plants

    International Nuclear Information System (INIS)

    2000-09-01

    This report presents the safety issues in 'small series' WWER-1000 nuclear power plants (NPPs). Safety issues are deviations from current recognized safety practices in design and operation judged to be safety significant by their impact on the plants' defence in depth. This report is intended to serve as reference for the development of plant specific safety improvement programmes and for the evaluation of measures proposed and/or implemented. The identification of safety issues is based on safety studies conducted by the operators of 'small series' WWER-1000 units and by organizations dealing with these reactors, on findings of IAEA safety missions to 'small series' WWER-1000 plants in South Ukraine, at Novovoronezh and Kalinin, and on information obtained from specialists from various countries during an IAEA consultants meeting, 8-12 September 1997 in Vienna, within the framework of the Extra budgetary Programme on the Safety of WWER and RBMK NPPs. Safety issues are first presented according to their impact on the main safety functions and are then described individually. The safety issues are characterized by issue title and specified by issue clarification. Safety issues connected with plant design are followed by the ranking of the issue and ranking justification. Altogether 85 safety issues have been identified, 12 of which are in Category III (defence in depth is insufficient, immediate corrective action is necessary), 38 in Category 11 (defence in depth is degraded, action is needed to resolve the issue) and 22 in Category I (departure from international practices, to be addressed as part of actions to resolve higher priority issues). In the case of operational safety issues (13 safety issues) no ranking is provided as the available material was considered insufficient. For each safety issue, comments and recommendations are made by the IAEA; the status of corresponding measures to improve safety implemented or planned at each site are presented in the

  11. Recommended reactor coolant water chemistry requirements for WWER-1000 units with 235U higher enriched fuel

    International Nuclear Information System (INIS)

    Dobrevski, I.; Zaharieva, N.

    2011-01-01

    The last decade worldwide experience of PWRs and WWERs confirms the trends for the improvement of the nuclear power industry electricity production through the implementation of high burn-up or high fuel duty, which are usually accompanied with the usage of UO 2 fuel with higher content of 235 U - 4.0% - 4.5% (5.0%). It was concluded that the onset of sub-cooled nucleate boiling (SNB) on the fuel cladding surfaces and the initial excess reactivity of the core are the primary and basic factors accompanying the implementation of uranium fuel with higher 235 U content, aiming extended fuel cycles and higher burn-up of the fuel in Pressurized Water Reactors. As main consequences of the presence of these factors the modifications of chemical / electrochemical environments of nuclear fuel cladding- and reactor coolant system- surfaces are evaluated. These conclusions are the reason for: 1) The determination of the choices of the type of fuel cladding materials in respect with their enough corrosion resistance to the specific fuel cladding environment, created by the presence of SNB; 2) The development and implementation of primary circuit water chemistry guidelines ensuring the necessary low corrosion rates of primary circuit materials and limitation of cladding deposition and out-of-core radioactivity buildup; 3) Implementation of additional neutron absorbers which allow enough decrease of the initial concentration of H 3 BO 3 in coolant, so that its neutralization will be possible with the permitted alkalising agent concentrations. In this paper the specific features of WWER-1000 units in Bulgarian Nuclear Power Plant; use of 235 U higher enriched fuel in the WWER-1000 reactors in the Kozloduy NPP; coolant water chemistry and radiochemistry plant data during the power operation period of the Kozloduy NPP Unit 5, 15 th fuel cycle; evaluation of the approaches and results by the conversion of the WWER-1000 Units at the Kozloduy NPP to the uranium fuel with 4.3% 235 U as

  12. The summary of WWER-1000 fuel utilization in Ukraine

    Energy Technology Data Exchange (ETDEWEB)

    Afanasyev, A [Ukrainian State Committee on Nuclear Power Utilization, Kiev (Ukraine)

    1997-12-01

    The report discusses the status of the fuel and fuel cycles of WWER-1000 reactors in Ukraine. The major reasons that caused the Ukrainian utilities to overcome the conservative design solutions in order to improve fuel utilization and extend fuel burnup are shown. At the same time the sufficient fuel reliability and fuel cycle flexibility are ensured. The burnup distribution in the unloaded fuel assemblies and average fuel rod failure rate are presented. The questions of reactor core operation safety and the economical problems of the front end of the fuel cycle are also considered. (author). 2 refs, 3 figs, 4 tabs.

  13. 1000 MW steam turbine for Temelin nuclear power station

    International Nuclear Information System (INIS)

    Drahy, J.

    1992-01-01

    Before the end 1991 the delivery was completed of the main parts (3 low-pressure sections and 1 high-pressure section, all of double-flow design) of the first full-speed (3000 r.p.m.) 1000 MW steam turbine for saturated admission steam for the Temelin nuclear power plant. Description of the turbine design and of new technologies and tools used in the manufacture are given. Basic technical parameters of the steam turbine are as follows: maximum output of steam generators 6060 th -1 ; maximum steam flow into turbine 5494.7 th -1 ; output of turbo-set 1024 MW; steam conditions before the turbine inlet: pressure 5.8 MPa, temperature 273.3 degC, steam wetness 0.5%; nominal temperature of cooling water 21 degC; temperature of feed water 220.8 degC; maximum consumption of heat from turbine for heating at 3-stage heating of heating water 60/150 degC. (Z.S.) 7 figs., 2 refs

  14. Use of Main Loop Isolating Valves (GZZS) in WWER 440

    International Nuclear Information System (INIS)

    Stefanova, A.E.; Gencheva, R.V.; Groudev, P.P.

    2002-01-01

    This paper discusses the usage of Main Loop Isolation Valves in case of Steam Generator Tube Rupture accident in WWER440/V230. A double-ended single pipe break in SG-6 was chosen as representative. In the paper are investigated two cases. In the first one the operator isolates the affected loop by Main Loop Isolation Valves closing and after primary depressurization re-opens them to cooldown the damaged Steam Generator. The second case treats the situation, where Main Loop Isolation Valves fail to close with the necessary operator actions for managing plant recovery. RELAP5/MOD3.2 computer code has been used to simulate the Steam Generator Tube Rupture accident in WWER440 NPP model. This model was developed and validated at Institute for Nuclear Research and Nuclear Energy - Bulgarian Academy of Sciences. The results of analyses presented in this report demonstrate that in the both cases (with or without Main Loop Isolation Valves usage) the operator could bring the plant to stable and safety conditions (Authors)

  15. On steady-state concentrations of ammonia and molecular hydrogen in the primary circuit of the WWER-1000 reactors

    International Nuclear Information System (INIS)

    Arkhipov, O.P.; Bugaenko, V.L.; Kamakchi, S.A.

    1997-01-01

    It is shown that the MORAVA-N2 software package describes well the coolant state in the primary circuit of an actual reactor facility with the WWER-1000 during on-load operation. It permits using the package for analysis of process perturbation effect on the coolant composition. Specific feature of ammonia radiation chemistry in the primary circuit of a reactor facility with the WWER-1000, assuring the rates hydrogen concentration in the coolant with ammonia concentration variation in the coolant within wide limits, when reactor operates on power, can be mentioned by way of example, the fact being ascertained in this study

  16. Substantiation of operation limits of reactivity insertion during WWER-1000 reactors start-up; Obosnovanie ehkspluatatsionnykh predelov vvoda reaktivnosti pri puske reaktorov WWER-1000

    Energy Technology Data Exchange (ETDEWEB)

    Boev, I; Sabitov, A; Sal` kov, V; Sudarev, O; Yakovlev, A [ATOMTECHENERGO RF, Novovoronezh (Russian Federation)

    1996-12-31

    The methods and programmes used to define the tolerable rate of reactivity insertion during WWER-1000 start-up are presented. They include calculation of the neutron source power in the core during the sub-critical stage and calculation of the relative neutron density and reactor period during the critical stage. The need for optimisation and regulation of tolerable rates is discussed along with the tool parameters affecting the reactivity during start-up. The possibility of increasing the feed rate of pure condensate into the first loop during the time needed to reach critical stage is justified. 4 refs., 3 tabs.

  17. Electromagnetism Mechanism for Enhancing the Refueling Cycle Length of a WWER-1000

    Directory of Open Access Journals (Sweden)

    Navid Poursalehi

    2017-02-01

    Full Text Available Increasing the operation cycle length can be an important goal in the fuel reload design of a nuclear reactor core. In this research paper, a new optimization approach, electromagnetism mechanism (EM, is applied to the fuel arrangement design of the Bushehr WWER-1000 core. For this purpose, a neutronic solver has been developed for calculating the required parameters during the reload cycle of the reactor. In this package, two modules have been linked, including PARCS v2.7 and WIMS-5B codes, integrated in a solver for using in the fuel arrangement optimization operation. The first results of the prepared package, along with the cycle for the original pattern of Bushehr WWER-1000, are compared and verified according to the Final Safety Analysis Report and then the results of exploited EM linked with Purdue Advanced Reactor Core Simulator (PARCS and Winfrith Improved Multigroup Scheme (WIMS codes are reported for the loading pattern optimization. Totally, the numerical results of our loading pattern optimization indicate the power of the EM for this problem and also show the effective improvement of desired parameters for the gained semi-optimized core pattern in comparison to the designer scheme.

  18. Electromagnetism mechanism for enhancing the refueling cycle length of a WWER-1000

    Energy Technology Data Exchange (ETDEWEB)

    Poursalehi, Navid; Nejati-Zadeh, Mostafa; Minuchehr, Abdolhamid [Dept. of Nuclear Engineering, Shahid Beheshti University, Tehran (Iran, Islamic Republic of)

    2017-02-15

    Increasing the operation cycle length can be an important goal in the fuel reload design of a nuclear reactor core. In this research paper, a new optimization approach, electromagnetism mechanism (EM), is applied to the fuel arrangement design of the Bushehr WWER-1000 core. For this purpose, a neutronic solver has been developed for calculating the required parameters during the reload cycle of the reactor. In this package, two modules have been linked, including PARCS v2.7 and WIMS-5B codes, integrated in a solver for using in the fuel arrangement optimization operation. The first results of the prepared package, along with the cycle for the original pattern of Bushehr WWER-1000, are compared and verified according to the Final Safety Analysis Report and then the results of exploited EM linked with Purdue Advanced Reactor Core Simulator (PARCS) and Winfrith Improved Multigroup Scheme (WIMS) codes are reported for the loading pattern optimization. Totally, the numerical results of our loading pattern optimization indicate the power of the EM for this problem and also show the effective improvement of desired parameters for the gained semi-optimized core pattern in comparison to the designer scheme.

  19. Application of the LBB regulatory approach to the steamlines of advanced WWER 1000 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kiselyov, V.A.; Sokov, L.M.

    1997-04-01

    The LBB regulatory approach adopted in Russia in 1993 as an extra safety barrier is described for advanced WWER 1000 reactor steamline. The application of LBB concept requires the following additional protections. First, the steamline should be a highly qualified piping, performed in accordance with the applicable regulations and guidelines, carefully screened to verify that it is not subjected to any disqualifying failure mechanism. Second, a deterministic fracture mechanics analysis and leak rate evaluation have been performed to demonstrate that postulated through-wall crack that yields 95 1/min at normal operation conditions is stable even under seismic loads. Finally, it has been verified that the leak detection systems are sufficiently reliable, diverse and sensitive, and that adequate margins exist to detect a through wall crack smaller than the critical size. The obtained results are encouraging and show the possibility of the application of the LBB case to the steamline of advanced WWER 1000 reactor.

  20. Application of the LBB regulatory approach to the steamlines of advanced WWER 1000 reactor

    International Nuclear Information System (INIS)

    Kiselyov, V.A.; Sokov, L.M.

    1997-01-01

    The LBB regulatory approach adopted in Russia in 1993 as an extra safety barrier is described for advanced WWER 1000 reactor steamline. The application of LBB concept requires the following additional protections. First, the steamline should be a highly qualified piping, performed in accordance with the applicable regulations and guidelines, carefully screened to verify that it is not subjected to any disqualifying failure mechanism. Second, a deterministic fracture mechanics analysis and leak rate evaluation have been performed to demonstrate that postulated through-wall crack that yields 95 1/min at normal operation conditions is stable even under seismic loads. Finally, it has been verified that the leak detection systems are sufficiently reliable, diverse and sensitive, and that adequate margins exist to detect a through wall crack smaller than the critical size. The obtained results are encouraging and show the possibility of the application of the LBB case to the steamline of advanced WWER 1000 reactor

  1. EVALUATION OF EYE LENS DOSE TO WORKERS IN THE STEAM GENERATOR AT THE KOREAN OPTIMIZED POWER REACTOR 1000.

    Science.gov (United States)

    Maeng, Sung Jun; Kim, Jinhwan; Cho, Gyuseong

    2018-03-15

    ICRP (2011) revised the dose limit to the eye lens to 20 mSv/y based on a recent epidemiological study of radiation-induced cataracts. Maintenance of steam generators at nuclear power plants is one of the highest radiation-associated tasks within a non-uniform radiation field. This study aims to evaluate eye lens doses in the steam generators of the Korean OPR1000 design. The source term was characterized based on the CRUD-specific activity, and both the eye lens dose and organ dose were simulated using MCNP6 combined with an ICRP voxel phantom and a mesh phantom, respectively. The eye lens dose was determined to be 5.39E-02-9.43E-02 Sv/h, with a negligible effect by beta particles. As the effective dose was found to be 0.81-1.21 times the lens equivalent dose depending on the phantom angles, the former can be used to estimate the lens dose in the SG of the OPR1000 for radiation monitoring purposes.

  2. Performance of the Westinghouse WWER-1000 fuel design

    International Nuclear Information System (INIS)

    Höglund, J.; Jansson, A.; Latorre, R.; Davis, D.

    2015-01-01

    In 2005, six (6) Westinghouse WWER-1000 Lead Test Assemblies (LTAs) were loaded in South Ukraine Unit 3 (SU3). The LTAs completed the planned four cycles of operation and reached an average assembly burnup in excess of 43 MWd/ kgU. Post Irradiation Examination (PIE) inspections were performed after completion of each cycle and it was concluded that the 6 Westinghouse LTAs performed as expected during their operational regimes. In 2010, a full region of 42 assemblies of an enhanced WWER-1000 fuel design for Ukrainian reactors, designated WFA, was loaded in SU3. The WFA includes features that further mitigate assembly bow while at the same time improving the fuel cycle economy. In 2015, 26 WFAs completed their planned four cycles of operation reaching an average assembly burnup in excess of 42 MWd/ kgU. Currently 36 WFAs continue operating their fourth cycle in SU3. In addition, South Ukraine Unit 2 (SU2) has been loaded with WFAs and 27 assemblies have completed two cycles of operation reaching an average assembly burnup above 24 MWd/kgU. PIE for the WFAs has been completed after each cycle of operation. All assemblies have been examined for visible damage or non-standard position of fuel assembly components during unloading and reloading. All WFAs have also been subject to the standard leak testing process, with all fuel rods found to be hermetically sealed and non-leaking. Each outage, six WFAs have been subject to a more extensive inspection program. In 2012, 2013, and 2015, the Westinghouse Fuel Inspection and Repair Equipment (FIRE) workstation were used for the SU3 inspections. Excellent irradiation fuel performance has been observed and measured on all WFAs. The fuel assembly growth, rod cluster control assembly (RCCA) drag forces, oxide thickness, total fuel rod-to-nozzle gap channel closure, and fuel assembly bow data were within the bounds of the Westinghouse experience database. Results and concluding remarks from the PIEs are provided in this paper. In

  3. Safety problems of nuclear power plants with reactors of new generation; Voprosy bezopasnosti v proehktakh AEhS novogo pokoleniya s WWER

    Energy Technology Data Exchange (ETDEWEB)

    Fedorov, V; Rogov, M; Biryukov, G [Opytno-Konstruktorskoe Byuro Gidropress, Podol` sk (Russian Federation)

    1996-12-31

    Modernization schemes for safety enhancement of WWER-1000 reactors are proposed. In the case of WWER-1000/V-392 it is based on introduction of additional safety systems and overall design improvement. For WWER-1100 (1000-1100 MW) the safety is enhanced by passive systems built from two-stage heat exchangers. For WWER-500/600 the use of passive safety system is extended to emergency cooling of the active zone and removal of the residual heat emissions from the reactor. The technical characteristics of the three reactors are compared. 3 figs., 1 tab.

  4. Report of a consultants meeting on control rod insertion reliability for WWER-1000 nuclear power plants. Extrabudgetary programme on the safety of WWER and RBMK nuclear power plants

    International Nuclear Information System (INIS)

    1995-09-01

    Starting from 1992, an increased drop time of control rods exceeding the design limit of four seconds has been observed in most of the operating WWER-1000 reactors in Russia and in the Ukraine. In some cases a dropped control rod became stuck in an intermediate position near the bottom of the core. In October 1994, a similar control rod problem was also observed at Unit 6 of the Kozloduy NPP. The issue of control rod insertion reliability was considered at a consultants' meeting on ''Core Control and Protection Strategy of WWER-1000 Reactors'' in April 1994. A consultants' meeting specifically focused on ''Control Rod Insertion Reliability'' was convened in Vienna in February 1995 attended by 15 international experts. The objectives of this meeting were: The exchange of international experience on problems and solutions related to anomalous control rod insertion; judgement of the safety concern of this issue for WWER-1000 reactors based on safety analyses; consideration of regulatory requirements and interim measures to continue operation in short term including modifications implemented or planned; and, status of root cause analyses and pending problems. The technical discussions were held in plenary sessions and in three working groups devoted to specific aspects of the issue. Refs, figs, tabs

  5. Experimental verification of FA for WWER-1000. Investigations of TVS - 2M

    International Nuclear Information System (INIS)

    Vasilchenko, I.; Seleznev, A.; Kobelev, S.; Makarov, V.; Afanasjev, A.; Matvienko, I.; Enin, A.; Ustimenko, A.; Volkov, S.

    2008-01-01

    During development of TVS-2M design for WWER-1000 and within the scope of its pre-reactor verification there was performed a complex of bench tests of FA for operational impacts. These tests were carried out with the use of the full-scale non-irradiated FA dummy and the models of units. The present report presents the methods and the results of tests of the full-scale dummy for static concentrated loads, impact of thermal cycling and vibration under separate and simultaneous impact of the listed loads. The results of tests carried out indicate that the solutions implemented in TVS-2M, first of all, a rigid welded skeleton, provide much higher resistance to distortion due to thermomechanical loads in comparison with zirconium AFA of the previous generation. This work was organized by JSC TVEL. (authors)

  6. Data bank on hydrodynamics, thermal tests and tube temperature regimes of PGV-4 and PVG-1000 natural steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Ageev, A.G.; Vasileva, R.V.; Nigmatulin, B.I.; Titov, V.F.; Tarankov, G.N. [EREC Electrogorsk Research and Engineering Centre of Nuclear Plants Safety, Moscow (Russian Federation)

    1995-12-31

    The data bank was prepared by EREC, OKB `Hydropress` using results of static and dynamic tests of PGV-4 and PGV- 1000 natural steam generators cared out at Kolskaya, Novo-Voronezhskaya, Ugno-Ukrainskaya, Balakov-skaya and Hmelnitskaya NPP within period of 1974-1993. It is destined for making calculation codes verification. (authors).

  7. Data bank on hydrodynamics, thermal tests and tube temperature regimes of PGV-4 and PVG-1000 natural steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Ageev, A G; Vasileva, R V; Nigmatulin, B I; Titov, V F; Tarankov, G N [EREC Electrogorsk Research and Engineering Centre of Nuclear Plants Safety, Moscow (Russian Federation)

    1996-12-31

    The data bank was prepared by EREC, OKB `Hydropress` using results of static and dynamic tests of PGV-4 and PGV- 1000 natural steam generators cared out at Kolskaya, Novo-Voronezhskaya, Ugno-Ukrainskaya, Balakov-skaya and Hmelnitskaya NPP within period of 1974-1993. It is destined for making calculation codes verification. (authors).

  8. Methodology for the evaluation of tolerability of defects in WWER-1000/V-320 reactor pressure vessels

    International Nuclear Information System (INIS)

    Brumovsky, M.; Horacek, L.; Ruscak, M.

    1996-05-01

    The methodology provides guidelines for the assessment of tolerability of defects found during in-service inspection of the base material and overlay of WWER-1000/V-320 type reactor pressure vessels. With regard to the method of calculating the tolerability of defects and rules for the preparation and implementation of repairs, this methodology can also find use in the assessment of tolerability of defects in selected facilities of WWER-1000/V-320 type nuclear power plants provided that adequate input data concerning the materials, manufacturing technology, and operating load regime are available and that the facilities are made of ferrite/bainite type steels. This methodology should serve as a binding document underlying the development of a technical approach to provisions for a further operation of facilities in which intolerable defects have been found by nondestructive testing. (author)

  9. The Evaluation of Steam Generator Level Measurement Model for OPR1000 Using RETRAN-3D

    International Nuclear Information System (INIS)

    Doo Yong Lee; Soon Joon Hong; Byung Chul Lee; Heok Soon Lim

    2006-01-01

    Steam generator level measurement is important factor for plant transient analyses using best estimate thermal hydraulic computer codes since the value of steam generator level is used for steam generator level control system and plant protection system. Because steam generator is in the saturation condition which includes steam and liquid together and is the place that heat exchange occurs from primary side to secondary side, computer codes are hard to calculate steam generator level realistically without appropriate level measurement model. In this paper, we prepare the steam generator models using RETRAN-3D that include geometry models, full range feedwater control system and five types of steam generator level measurement model. Five types of steam generator level measurement model consist of level measurement model using elevation difference in downcomer, 1D level measurement model using fluid mass, 1D level measurement model using fluid volume, 2D level measurement model using power and fluid mass, and 2D level measurement model using power and fluid volume. And we perform the evaluation of the capability of each steam generator level measurement model by simulating the real plant transient condition, the title is 'Reactor Trip by The Failure of The Deaerator Level Control Card of Ulchin Unit 3'. The comparison results between real plant data and RETRAN-3D analyses for each steam generator level measurement model show that 2D level measurement model using power and fluid mass or fluid volume has more realistic prediction capability compared with other level measurement models. (authors)

  10. Fuel element cladding state change mathematical model for a WWER-1000 plant operated in the mode of varying loading

    Directory of Open Access Journals (Sweden)

    S. N. Pelykh

    2010-09-01

    Full Text Available Main features of a fuel element cladding state change mathematical model for a WWER-1000 reactor plant operated in the mode of varying loading are listed. The integrated model is based on the energy creep theory, uses the finite element method for imultaneous solution of the fuel element heat conduction and mechanical deformation equa-tions. Proposed mathematical model allows us to determine the influence of the WWER-1000 regime parameters and fuel assembly design characteristics on the change of cladding properties under different loading conditions of normal operation, as well as the cladding limiting state at variable loading depending on the length, depth and number of cycles.

  11. Operational monitoring of temperature and state of stress of primary collectors, their stud bolts and cover and temperatures of steam generator's pressure vessel at the nuclear power unit WWER 440

    International Nuclear Information System (INIS)

    Matal, O.; Simo, T.; Holy, F.; Vejvoda, S.

    1992-01-01

    Both primary collectors of the WWER 440 steam generator (STGE) are vertically positioned inside the STGE pressure vessel and connected in their lower part to the primary piping and closed at their upper part by primary covers. The primary cover is pushed against the primary collector flange by 20 stud bolts. Two nickel packing rings are fitted between the primary cover and collector. A leakage in the collector-cover junction could cause flow of the radioactive water into the clean secondary water. If the junction is made in accordance with the Soviet standard design the computed stresses exceed the allowable value in the stud bolts by a factor of 1.5. Therefore an improved design of the primary collector - primary cover flange joint was designed and tested on one STGE at a WWER 440 nuclear power unit in Czechoslovakia. The paper describes the system of joint properties measurement, gives some substantial characteristics of the new stud bolts and primary cover design and comments on significant measured results of state of stress and temperatures in comparison with the operational regime of the STGE. (orig.)

  12. Best estimate modeling of fuel thermomechanical behaviour in WWER 1000 LB LOCA

    International Nuclear Information System (INIS)

    Valach, M.; Klouzal, J.; Zymak, J.; Dostal, M.

    2009-01-01

    The paper summarizes our calculations of the performance of the WWER 1000 NPP fuel rods during postulated LB LOCA. The thermomechanical modeling was performed by FRAPTRAN using the FRACAS-I mechanical model using the boundary conditions calculated by the ATHLET code. The results and their statistical evaluation are presented, the process of the generalization of gained insight into the best-estimate thermal-hydraulic analyses (BE TM) predictions in order to define a generic BE TM methodology is outlined (authors)

  13. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 3E. Kozloduy NPP units 5/6: Analysis/testing. Working material

    International Nuclear Information System (INIS)

    1996-01-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains reports on data related to floor response spectra of Kozloduy NPP; calculational-experimental examination and ensuring of equipment and pipelines seismic resistance at starting and operating WWER-type NPPs; analysis of design floor response spectra and testing of the electrical systems; experimental investigations and seismic analysis Kozloduy NPP; testing of components on the shaking table facilities and contribution to full scale dynamic testing of Kozloduy NPP; seismic evaluation of the main steam line, piping systems, containment pre-stressing and steel ventilation chimney of Kozloduy NPP

  14. Technological problems connected with execution of the protection sheets for nuclear power sets WWER-1000

    International Nuclear Information System (INIS)

    Hajutin, J.G.; Kriczewskij, A.Z.

    1977-01-01

    The choice of the structure and the prestressing system of the R.C. protection sheet for nuclear power sets WWER-1000 is motivated. The technological problems arised during the execution stage, as well as the technological line producing the tendons to prestress the structure by up winding are presented. (author)

  15. Improvement of operation efficiency for WWER-440 and WWER-1000 for TRIGON fuel assembly design features

    Energy Technology Data Exchange (ETDEWEB)

    Silberstein, A [European WWER Fuels GmbH, Lyon (France)

    1994-12-31

    TRIGON 440 and TRIGON 1000 fuel assemblies and their assembly matching counterparts are described. Their role in increasing the efficiency of WWER reactors is stressed. Special attention is paid to their design features as well as calibrated means of predicting behaviour under irradiation from light water reactor core operation. They reduce the fuel cycle cost as a result of the reduced need for natural uranium which have to be enriched and of the smaller number of fuel assemblies which have to be fabricated, stored or reprocessed. The improved control assemblies bring comfort to the plant operator due to intrinsic progress in safety with respect to accidental situation, trouble-free behaviour and long time utilization in the reactor. 14 figs.

  16. Experimental study of the passive flooding system in the WWER-1000 reactor

    International Nuclear Information System (INIS)

    Malyshev, A.B.; Efanov, A.D.; Kalyakin, S.G.

    2002-01-01

    The design solution of the passive flooding system in the WWER-1000 reactor core with the V-392 reactor facility and the scheme of the GE-2 large-scale thermohydraulic stand for substantiation of its functions are presented. The proposals, improving the efficiency of the system are developed on the basis of the experimental studies on the equipment input-output operational characteristics and the recommendations on the substantiation of the function of the reactor core flooding system are given [ru

  17. Experience in adjusting of the level regulation system of steam generators of the Rovno NPP

    International Nuclear Information System (INIS)

    Patselyuk, S.N.; Sokolov, A.G.; Kazakov, V.I.; Dorosh, Yu.A.

    1984-01-01

    A system of feed water level control in steam generators at the Rovno NPP with WWER-440 reactors which comprises start-up as well as main regulators is described. The start-up regulator (single-pulsed with a signal by the level) keeps the level in the steam generator at loadings up to 30% of the nominal reactor power Nsub(nom.) The main regulator is connected in the three-pulsed circuit and it receives signals by steam and water flow rate and by the level in the steam generator. The main regulator has been started only at loadings above 40% Nsub(nom.). After reconstruction it was used in the 15-100% Nsub(nom.) range. Characteristics of the level control system in the steam generator at perturbations intoduced by the main circulating pump (MCP) and turbine disconnection as well as change in feed water flow rate have been studied. The studies have revealed that the system ensures necessary quality of control in stationary modes. The system operates stably at perturbations of feed water flow rate up to 50% Nsub(nom.). Perturbations by MCP connections and disconnections is most difficult for control system

  18. WWER radial reflector modeling by diffusion codes

    International Nuclear Information System (INIS)

    Petkov, P. T.; Mittag, S.

    2005-01-01

    The two commonly used approaches to describe the WWER radial reflectors in diffusion codes, by albedo on the core-reflector boundary and by a ring of diffusive assembly size nodes, are discussed. The advantages and disadvantages of the first approach are presented first, then the Koebke's equivalence theory is outlined and its implementation for the WWER radial reflectors is discussed. Results for the WWER-1000 reactor are presented. Then the boundary conditions on the outer reflector boundary are discussed. The possibility to divide the library into fuel assembly and reflector parts and to generate each library by a separate code package is discussed. Finally, the homogenization errors for rodded assemblies are presented and discussed (Author)

  19. The international WWER fuel market

    International Nuclear Information System (INIS)

    Gingold, G.E.; Goldstein, L.; Strasser, A.A.

    1994-01-01

    The state of the world nuclear fuel market and its economic complexities are described. Currently the nuclear fuel market is oversupplied and nuclear fuel fabrication in the West far exceeds the anticipated demands. Actually the current demand is not much more than half of the capacity available to supply it. The Eastern Europe (excluding the plants in the Russian Federation) with its 20 WWER-440 and 12 WWER-1000 reactors in operation and additional 4 WWER-440 and 8 WWER-1000 units under construction is considered as a potential long-term market for the Western fuel fabricators. The following significant benefits of competition in the WWER fuel market for the operators of these reactors are : 1) lower cost; 2) more favorable contract terms and improved vendor cooperation with the customer; 3) accelerated technological development. A brief description of the main WWER fuel suppliers TVEL, ABB Atom, BNFL, EVF and Westinghouse, as well as the status of some new companies as CEZ and SEP is given. The principal differences between Western and WWER fuels are outlined. The advanced features offered by the Western vendors and Russian fuel supply organisations are discussed. 2 tabs., 1 fig

  20. The international WWER fuel market

    Energy Technology Data Exchange (ETDEWEB)

    Gingold, G E; Goldstein, L; Strasser, A A [Stoller (S.M.) Corp., Pleasantville, NY (United States)

    1994-12-31

    The state of the world nuclear fuel market and its economic complexities are described. Currently the nuclear fuel market is oversupplied and nuclear fuel fabrication in the West far exceeds the anticipated demands. Actually the current demand is not much more than half of the capacity available to supply it. The Eastern Europe (excluding the plants in the Russian Federation) with its 20 WWER-440 and 12 WWER-1000 reactors in operation and additional 4 WWER-440 and 8 WWER-1000 units under construction is considered as a potential long-term market for the Western fuel fabricators. The following significant benefits of competition in the WWER fuel market for the operators of these reactors are : (1) lower cost; (2) more favorable contract terms and improved vendor cooperation with the customer; (3) accelerated technological development. A brief description of the main WWER fuel suppliers TVEL, ABB Atom, BNFL, EVF and Westinghouse, as well as the status of some new companies as CEZ and SEP is given. The principal differences between Western and WWER fuels are outlined. The advanced features offered by the Western vendors and Russian fuel supply organisations are discussed. 2 tabs., 1 fig.

  1. Plugging criteria for WWER SG tubes

    Energy Technology Data Exchange (ETDEWEB)

    Papp, L.; Wilam, M. [Vitkovice NPP Services (Switzerland); Herman, M. [Vuje, Trnava (Slovakia)

    1997-12-31

    At operated Czech and Slovak nuclear power plants the 80 % criteria for crack or other bulk defect depth is used for steam generator heat exchanging tubes plugging. This criteria was accepted as the recommendation of designer of WWER steam generators. Verification of this criteria was the objective of experimental program performed by Vitkovice, J.S.C., UJV Rez, J.S.C. and Vuje Trnava, J.S.C .. Within this program the following factors were studied: (1) Influence of secondary water chemistry on defects initiation and propagation, (2) Statistical evaluation of corrosion defects progression at operated SG, and (3) Determination of critical pressure for tube rupture as a function of eddy current indications. In this presentation items (2) and (3) are considered.

  2. Plugging criteria for WWER SG tubes

    Energy Technology Data Exchange (ETDEWEB)

    Papp, L; Wilam, M [Vitkovice NPP Services (Switzerland); Herman, M [Vuje, Trnava (Slovakia)

    1998-12-31

    At operated Czech and Slovak nuclear power plants the 80 % criteria for crack or other bulk defect depth is used for steam generator heat exchanging tubes plugging. This criteria was accepted as the recommendation of designer of WWER steam generators. Verification of this criteria was the objective of experimental program performed by Vitkovice, J.S.C., UJV Rez, J.S.C. and Vuje Trnava, J.S.C .. Within this program the following factors were studied: (1) Influence of secondary water chemistry on defects initiation and propagation, (2) Statistical evaluation of corrosion defects progression at operated SG, and (3) Determination of critical pressure for tube rupture as a function of eddy current indications. In this presentation items (2) and (3) are considered.

  3. Numerical modeling of secondary side thermohydraulics of horizontal steam generator

    Energy Technology Data Exchange (ETDEWEB)

    Melikhov, V.I.; Melikhov, O.I.; Nigmatulin, B.I. [Research and Engineering Centre of LWR Nuclear Plants Safety, Moscow (Russian Federation)

    1995-12-31

    A mathematical model for the transient three-dimensional secondary side thermal hydraulics of the horizontal steam generator has been developed. The calculations of the steam generator PGV-1000 and PGV-4 nominal regimes and comparison of numerical and experimental results have been carried out. 7 refs.

  4. Numerical modeling of secondary side thermohydraulics of horizontal steam generator

    Energy Technology Data Exchange (ETDEWEB)

    Melikhov, V I; Melikhov, O I; Nigmatulin, B I [Research and Engineering Centre of LWR Nuclear Plants Safety, Moscow (Russian Federation)

    1996-12-31

    A mathematical model for the transient three-dimensional secondary side thermal hydraulics of the horizontal steam generator has been developed. The calculations of the steam generator PGV-1000 and PGV-4 nominal regimes and comparison of numerical and experimental results have been carried out. 7 refs.

  5. VUJE's experience in the field of thermal-hydraulic behaviour of WWER

    International Nuclear Information System (INIS)

    Klepach, J.

    1995-01-01

    The thermal-hydraulic behavior (THB) of NPP coolant system and its consequences to nuclear safety of WWER reactors in previous Czechoslovakia has been studied in the VUJE (Nuclear Power Plants Research Institute, Trnava, SK). The institute takes part in the development and verification of its own (SLAP, LENKA, PUMKO, SICHTA, TRACO etc.) and international (DYNAMIKA5) codes for thermal-hydraulic analysis. The verification efforts are concentrated on the WWER specific features such as horizontal steam generators, control and safety system functioning, etc. The whole range of NPP accident analyses is covered by the VUJe staff. The author outlined briefly the WWER specific features as design and implemented improvements in Bohunice V-1 and Mochovce V-1 (WWER 230 model). The pros and cons of the WWER design compared against western type PWR are described. It is believed that although the WWERs are designed under the rules and standards of 1960s, their safety and operational performance can be improved to acceptable level by thorough analysis and appropriate measures. 5 figs

  6. A connection of the steam generator feedwater section of WWER type nuclear power plants

    International Nuclear Information System (INIS)

    Matal, O.; Sadilek, J.

    1989-01-01

    In the feedwater piping of each steam generator, a plate for additional water pressure reduction is inserted before the first closing valve. During a steady water flow, the plate gives rise to a constant hydraulic resistance, bringing about steady reduction of the feedwater pressure; this also contributes to a stabilization of the feedwater flow rate into the steam generator. The control valve thus is stressed by minimal hydrodynamic forces. In this manner its load is decreased, its vibrations are damped, and the frequency of failures - and thereby the frequency of the nuclear power plant unit outages -is reduced. (J.P.). 1 fig

  7. Mathematical modelling and quality indices optimization of automatic control systems of reactor facility

    International Nuclear Information System (INIS)

    Severin, V.P.

    2007-01-01

    The mathematical modeling of automatic control systems of reactor facility WWER-1000 with various regulator types is considered. The linear and nonlinear models of neutron power control systems of nuclear reactor WWER-1000 with various group numbers of delayed neutrons are designed. The results of optimization of direct quality indexes of neutron power control systems of nuclear reactor WWER-1000 are designed. The identification and optimization of level control systems with various regulator types of steam generator are executed

  8. WWER-1000 reactor simulator. Workshop material

    International Nuclear Information System (INIS)

    2003-01-01

    The International Atomic Energy Agency (IAEA) has established an activity in nuclear reactor simulation computer programs to assist its Member States in education. The objective is to provide, for a variety of advanced reactor types, insight and practice in their operational characteristics and their response to perturbations and accident situations. To achieve this, the IAEA arranges for the development and distribution of simulation programs and educational material and sponsors courses and workshops. The workshops are in two parts: techniques and tools for reactor simulator development; and the use of reactor simulators in education. Workshop material for the first part is covered in the IAEA publication: Training Course Series 12, 'Reactor Simulator Development' (2001). Course material for workshops using a pressurized water reactor (PWR) Simulator developed for the IAEA by Cassiopeia Technologies Inc. of Canada is presented in the IAEA publication: Training Course Series No. 22 'Pressurized Water Reactor Simulator' (2003) and Training Course Series No. 23 'Boiling Water Reactor Simulator' (2003). This report consists of course material for workshops using the WWER-1000 Reactor Department Simulator from the Moscow Engineering and Physics Institute, Russian Federation. N. V. Tikhonov and S. B. Vygovsky of the Moscow Engineering and Physics Institute prepared this report for the IAEA

  9. The procedure for determination of special margin factors to account for a bow of the WWER-1000 fuel assemblies

    International Nuclear Information System (INIS)

    Tsyganov, S. V.; Marin, S. V.; Shishkov, L. K.

    2008-01-01

    Starting from 1980s, the problem of bow of the WWER-1000 reactor fuel assemblies and the effect of that on the operational safety is being discussed. At the initial period of time, the extension of time for dropping control rods of the control and protection system associated with this bow posed the highest threat. Later on, new more rigid structures were developed for fuel assemblies that eliminated the problems of control rods. However, bow of the WWER-1000 reactor fuel assemblies is observed up to now. The scale of this bow reduced significantly but it still effects safety. Even a minor bow available may lead to the noticeable increase of power of individual fuel pins associated with the local variation of the coolant amount. This effect must be taken into account on designing fuel loadings to eliminate the exceeding of set limitations. The introduction of additional special margins is the standard method for taking this effect into account. The present paper describes the conservative technique for the assessment of additional margins for bow of fuel assemblies of state-of-the-art designs. This technique is employed in the WWER-1000 reactor designing. The chosen conservatism degree is discussed as well as the method for its assurance and acceptable ways for its slackening. The example of the margin evaluation for the up-to-date fuel loading is given. (authors)

  10. The solution of the LEU and MOX WWER-1000 calculation benchmark with the CARATE - multicell code

    International Nuclear Information System (INIS)

    Hordosy, G.; Maraczy, Cs.

    2000-01-01

    Preparations for disposition of weapons grade plutonium in WWER-1000 reactors are in progress. Benchmark: Defined by the Kurchatov Institute (S. Bychkov, M. Kalugin, A. Lazarenko) to assess the applicability of computer codes for weapons grade MOX assembly calculations. Framework: 'Task force on reactor-based plutonium disposition' of OECD Nuclear Energy Agency. (Authors)

  11. WWER reactor physics code applications

    International Nuclear Information System (INIS)

    Gado, J.; Kereszturi, A.; Gacs, A.; Telbisz, M.

    1994-01-01

    The coupled steady-state reactor physics and thermohydraulic code system KARATE has been developed and applied for WWER-1000 and WWER-440 operational calculations. The 3 D coupled kinetic code KIKO3D has been developed and validated for WWER-440 accident analysis applications. The coupled kinetic code SMARTA developed by VTT Helsinki has been applied for WWER-440 accident analysis. The paper gives a summary of the experience in code development and application. (authors). 10 refs., 2 tabs., 5 figs

  12. Main examination results of WWER-1000 fuel after its irradiation in power reactors

    Energy Technology Data Exchange (ETDEWEB)

    Bibiliashvili, Yu [Vsesoyuznyj Nauchno-Issledovatel` skij Inst. Neorganicheskikh Materialov, Moscow (Russian Federation); Dubrovin, K [Russian Research Centre Kurchatov Inst., Moscow (Russian Federation); Vasilchenko, I [Opytno-Konstruktorskoe Byuro Gidropress, Podol` sk (Russian Federation); Yenin, A; Kushmanov, A [AO Novosibirskij Zavod Khimcontsentratov, Novosibirsk (Russian Federation); Smirnov, A; Smirnov, V [Nauchno-Issledovatel` skij Inst. Atomnykh Reaktorov, Dimitrovgrad (Russian Federation)

    1994-12-31

    WWER-1000 fuel examination has been undertaken to specify the properties of fuel assembly members by defining the parameters of their materials and their interconnection in power reactor operation conditions. Nine fuel assemblies are examined. The examination program includes: visual inspection, measurement of overall dimensions, eddy-current test, gamma-scanning, X-ray and neutron radiography, analysis of gas pressure and composition inside fuel rods, ceramography/metallography, mass spectrometry, microanalysis and electron microscopy of fuel and fuel claddings. The examination results suggest that WWER-1000 fuel spent at steady-state operation conditions up to 50 Mwd/kg U of burnup is in satisfactory condition. The examination of all types of fuel cladding failures indicates that the reason lies in the interaction of cladding with coolant solid impurities. The nodular cladding corrosion of fuel assembly discharged from the South-Ukrainian NPP is caused by the graphite compounds deposited on the fuel rod. Those deposits are a result of the circulating pump damage and had accidental, non-typical character. Some of the rods were found to have a small cladding `fretting` of the spacer grid cell material. The values of the majority of parameters determining the fuel efficiency allow to assume that there is a potential for further extension of fuel burnup and operation length. 1 tab., 11 figs.

  13. Main examination results of WWER-1000 fuel after its irradiation in power reactors

    International Nuclear Information System (INIS)

    Bibiliashvili, Yu.; Dubrovin, K.; Vasilchenko, I.; Yenin, A.; Kushmanov, A.; Smirnov, A.; Smirnov, V.

    1994-01-01

    WWER-1000 fuel examination has been undertaken to specify the properties of fuel assembly members by defining the parameters of their materials and their interconnection in power reactor operation conditions. Nine fuel assemblies are examined. The examination program includes: visual inspection, measurement of overall dimensions, eddy-current test, gamma-scanning, X-ray and neutron radiography, analysis of gas pressure and composition inside fuel rods, ceramography/metallography, mass spectrometry, microanalysis and electron microscopy of fuel and fuel claddings. The examination results suggest that WWER-1000 fuel spent at steady-state operation conditions up to 50 Mwd/kg U of burnup is in satisfactory condition. The examination of all types of fuel cladding failures indicates that the reason lies in the interaction of cladding with coolant solid impurities. The nodular cladding corrosion of fuel assembly discharged from the South-Ukrainian NPP is caused by the graphite compounds deposited on the fuel rod. Those deposits are a result of the circulating pump damage and had accidental, non-typical character. Some of the rods were found to have a small cladding 'fretting' of the spacer grid cell material. The values of the majority of parameters determining the fuel efficiency allow to assume that there is a potential for further extension of fuel burnup and operation length. 1 tab., 11 figs

  14. Modelling the WWER-type reactor dynamics using a hybrid computer. Part 1

    International Nuclear Information System (INIS)

    Karpeta, C.

    Results of simulation studies into reactor and steam generator dynamics of a WWER type power plant are presented. Spatial kinetics of the reactor core is described by a nodal approximation to diffusion equations, xenon poisoning equations and heat transfer equations. The simulation of the reactor model dynamics was performed on a hybrid computer. Models of both a horizontal and a vertical steam generator were developed. The dynamics was investigated over a large range of power by computing the transients on a digital computer. (author)

  15. Steam-Generator Integrity Program/Steam-Generator Group Project

    International Nuclear Information System (INIS)

    1982-10-01

    The Steam Generator Integrity Program (SGIP) is a comprehensive effort addressing issues of nondestructive test (NDT) reliability, inservice inspection (ISI) requirements, and tube plugging criteria for PWR steam generators. In addition, the program has interactive research tasks relating primary side decontamination, secondary side cleaning, and proposed repair techniques to nondestructive inspectability and primary system integrity. The program has acquired a service degraded PWR steam generator for research purposes. This past year a research facility, the Steam Generator Examination Facility (SGEF), specifically designed for nondestructive and destructive examination tasks of the SGIP was completed. The Surry generator previously transported to the Hanford Reservation was then inserted into the SGEF. Nondestructive characterization of the generator from both primary and secondary sides has been initiated. Decontamination of the channelhead cold leg side was conducted. Radioactive field maps were established in the steam generator, at the generator surface and in the SGEF

  16. Structural optimization of static power control programs of nuclear power plants with WWER-1000

    International Nuclear Information System (INIS)

    Kokol, E.O.

    2015-01-01

    The question of possibility the power control programs switching for WWER-1000 is considered. The aim of this research is to determine the best program for the power control of nuclear reactor under cyclic diurnal behavior of electrical generation, as well as the switching implementation. The considered problem of finding the best control program refers to the multicriteria optimization class of problems. Operation of the nuclear power generation system simulated using the following power control programs: with constant average temperature of transfer fluid, with constant pressure in the reactor secondary circuit, with constant temperature in input of the nuclear reactor. The target function was proposed. It consists of three normalized criteria: the burn up fraction, the damage level of fuel rod array shells, as well as changes in the power values. When simulation of the nuclear power generation system operation within the life was done, the values of the selected criteria were obtained and inserted in the target function. The minimum of three values of the target function depending on the control program at current time defined the criterion of switching of considered static power control programs for nuclear power generation system

  17. Calculational modeling of fuel assemblies of WWER-1000 type with the use of burnable absorber Gadolinum; comparative analysis

    International Nuclear Information System (INIS)

    Yeremenko, M.L.; Kovbasenko, Yu.P.; Loetsch, T.

    2001-01-01

    In connection with the beginning of the use of fuel assemblies with burnable absorbers by integration of Gadolinum into the nuclear fuel at Ukrainian NPP the task of testing the code systems and the pertinent neutron cross section libraries for the new fuel arose. Taking into account the long term experience of German experts with calculations and evaluation of nuclear fuel containing Gadolinum it was decided to carry out a series of test calculations for fuel assembly lattices of PWR, WWER-440 and WWER-1000 types using the NESSEL/PYTHIA and CASMO/SIMULATE code systems (Authors)

  18. Analysing The Thermalhydraulic Parameters Of VVER-1000 Reactor For The Accident Of Steam Generator Tube Rupture

    International Nuclear Information System (INIS)

    Luu Nam Hai; Truong Cong Thang

    2011-01-01

    To ensure the safety operation of nuclear power plant (NPP), a lot of postulated accident scenarios were considered and analysed. This research chose and analysed the accident of steam generator tube rupture (SGTR) under the actual plant conditions by using the simulation program PCTRAN. The SGTR accident is happen when the NPP is under operation with the steady state condition (power of 3000 MWth, primary pressure of 157 bar and secondary pressure of 63 bar). The accident is initiated by creating a break with equivalent diameter of 100 mm in the area of lower row heat exchanging tubes. The result of analysis is compared with the calculation of the Shariz University, Iran using the thermal hydraulics code RELAP5/mod3.2 and the report in the PSAR data of VVER-1000. This comparison shows that it is possible for using PCTRAN to analyse accidents of VVER-1000 reactor. (author)

  19. Report of the review of WWER-1000 safety issues resolution at Temelin nuclear power plant, Temelin, Czech Republic 11 to 15 March 1996

    International Nuclear Information System (INIS)

    Almeida, C.; Hoehn, J.; Seiberling, R.; Chambon, J.L.; Fil, N.S.; Munoz, A.; Roennberg, G.; Wenk, W.

    1996-01-01

    At the request of the Government of the Czech Republic, the IAEA conducted, in the period of 11-15 March 1996, a mission to review the resolution of WWER-1000 safety issues at Temelin NPP. These safety issues have been identified for WWER-1000 model 320 reactors and ranked according to their importance to safety in the frameworks of the IAEA Extrabudgetary Programme on Safety of WWER and RBMK Nuclear Power Plants. The Temelin NPP is a WWER-1000 and was originally designed according to standards of the former Soviet Union. After a series of reviews in the 1980s, a decision was taken by the Temelin NPP management to upgrade the design of Temelin, including the supply of fuel and instrumentation and control by a western company. The objective of the mission was to review the response of Temelin to the safety issues identified by the IAEA. The mission assessed the current Temelin design, including proposed modifications and plans for operation at Temelin, in the light of the IAEA recommendations for each relevant issue. The present report contains the mission's general conclusions and recommendations and an overview of the review performed in each topical area. The attachment contains a brief summary of the discussions on each individual safety issue and associated conclusions and recommendations. 3 refs

  20. Steam 80 steam generator instrumentation

    International Nuclear Information System (INIS)

    Carson, W.H.; Harris, H.H.

    1980-01-01

    This paper describes two special instrumentation packages in an integral economizer (preheater) steam generator of one of the first System 80 plants scheduled to go into commercial operation. The purpose of the instrumentation is to obtain accurate operating information from regions of the secondary side of the steam generator inaccessible to normal plant instrumentation. In addition to verification of the System 80 steam generator design predictions, the data obtained will assist in verification of steam generator thermal/hydraulic computer codes developed for generic use in the industry

  1. Analysis of expediency to set regulators of high-pressure emergency core cooling system of WWER 1000 (B-320)

    International Nuclear Information System (INIS)

    Skalozubov, V.I.; Komarov, Yu.A.; Tikhonova, G.G.; Nikiforov, S.N.; Bogodist, V.V.; Fol'tov, I.M.; Khadzh Faradzhallakh Dabbakh, A.

    2011-01-01

    The work shows that setting regulative valves in high-pressure emergency core cooling system of WWER 1000/B-320 can be effective only involving the additional tuning to account traverse speed of operating elements of regulator and configuration of the systems providing cooling of primary loop.

  2. Investigation of separation and hydrodynamic characteristics of steam generators used at the NPPs running on PWR-1000 reactors

    International Nuclear Information System (INIS)

    Ageev, A.G.; Korolkov, B.M.; Nigmatulin, B.I.; Vasileva, R.V.; Nekrasov, A.V.; Titiv, V.F.; Tarankov, G.A.

    1997-01-01

    The tests were accomplished at the steam generator of unit 5 of the Novovoronezh nuclear power plant. The outbursts of the steam-water mixture from the gap between the steam generator housing and the submerged perforated screen rim at the side of the inlet coolant manifold were investigated. Tests of the steam generator with a modified steam separation system were carried out on the Balakovo nuclear power plant. The gilled separator of the steam generator was replaced with a steam collecting perforated screen, while the gap between the steam generator housing and the heat exchange bundle rim was closed with additional perforated screens at the side of the inlet manifold. This new solution of moisture separation is better. (M.D.)

  3. Methodology of thermalhydraulic tests of fuel assemblies for WWER-1000

    International Nuclear Information System (INIS)

    Archipov, A.; Kolochko, V.N.

    2001-01-01

    At present 11 units with WWER-1000 are in operation in Ukraine. The NPPs are provided with nuclear fuel from Russia. The fuel assemblies are fabricated and delivered to Ukrainian NPPs from Russia. However the contemporary tendencies of nuclear energy development in the world assume a diversification of nuclear fuel vendors. Therefore the creation of the own nuclear fuel cycle of Ukraine is in mind in the strategy of nuclear energy development of Ukraine. As a part of the fuel assemblies fabrication process complex of the thermalhydraulic tests should be carried out to confirm design characteristics of the fuel assemblies before they are loaded in the reactor facility. The experimental basis and scientific infrastructure for the thermalhydraulic tests arrangement and realization of the programs and procedures for the core equipment examination are under consideration. (author)

  4. 1000 MW steam turbine for nuclear power station

    International Nuclear Information System (INIS)

    Drahy, J.

    1987-01-01

    Skoda Works started the manufacture of the 1000 MW steam turbine for the Temelin nuclear power plant. The turbine will use saturated steam at 3,000 r.p.m. It will allow steam supply to heat water for district heating, this of an output of 893 MW for a three-stage water heating at a temperature of 150/60 degC or of 570 MW for a two-stage heating at a temperature of 120/60 degC. The turbine features one high-pressure and three identical low-pressure stages. The pressure gradient between the high-pressure and the low-pressure parts was optimized as concerns the thermal efficiency of the cycle and the thermodynamic efficiency of the low-pressure part. A value of 0.79 MPa was selected corresponding to the maximum flow rate of the steam entering the turbine. This is 5,495 t/h, the admission steam parameters are 273.3 degC and 5.8 MPa. The feed water temperature is 220.9 degC. It is expected that throughout the life of the turbine, there will be 300 cold starts, 1,000 starts following shutdown for 55 to 88 hours, and 600 starts following shutdown for 8 hours. (Z.M.). 8 figs., 1 ref

  5. Experience in decontamination of the equipment of NPP's with the WWER-440 reactors

    International Nuclear Information System (INIS)

    Balaban-Irmenin, Yu.V.

    1981-01-01

    Different methods of decontamination at NPPs are briefly characterized. Decontamination of the removable part of the main circulation pump (MCP) of the WWER-440 reactor is considered as an example of removable equipment decontamination. A design of the decontamination bath of the removable MCP elements and the applied chemical agents are described. A decontamination flowsheet of the Novovoronezh NPP steam generator (SG) is considered as an example of the autonomic decontamination system. The SG decontamination modes, principal flowsheets of a hydromonitor, steam-ejection sprayer and steam-emulsion device are described [ru

  6. GENERATION, TRANSPORT AND DEPOSITION OF TUNGSTEN-OXIDE AEROSOLS AT 1000 C IN FLOWING AIR-STEAM MIXTURES.

    Energy Technology Data Exchange (ETDEWEB)

    GREENE,G.A.; FINFROCK,C.C.

    2001-10-01

    Experiments were conducted to measure the rates of oxidation and vaporization of pure tungsten rods in flowing air, steam and air-steam mixtures in laminar flow. Also measured were the downstream transport of tungsten-oxide condensation aerosols and their region of deposition, including plateout in the superheated flow tube, rainout in the condenser and ambient discharge which was collected on an array of sub-micron aerosol filters. The nominal conditions of the tests, with the exception of the first two tests, were tungsten temperatures of 1000 C, gas mixture temperatures of 200 C and wall temperatures of 150 C to 200 C. It was observed that the tungsten oxidation rates were greatest in all air and least in all steam, generally decreasing non-linearly with increasing steam mole fraction. The tungsten oxidation rates in all air were more than five times greater than the tungsten oxidation rates in all steam. The tungsten vaporization rate was zero in all air and increased with increasing steam mole fraction. The vaporization rate became maximum at a steam mole fraction of 0.85 and decreased thereafter as the steam mole fraction was increased to unity. The tungsten-oxide was transported downstream as condensation aerosols, initially flowing upwards from the tungsten rod through an 18-inch long, one-inch diameter quartz tube, around a 3.5-inch radius, 90{sup o} bend and laterally through a 24-inch horizontal run. The entire length of the quartz glass flow path was heated by electrical resistance clamshell heaters whose temperatures were individually controlled and measured. The tungsten-oxide plateout in the quartz tube was collected, nearly all of which was deposited at the end of the heated zone near the entrance to the condenser which was cold. The tungsten-oxide which rained out in the condenser as the steam condensed was collected with the condensate and weighed after being dried. The aerosol smoke which escaped the condenser was collected on the sub

  7. Comparative severe accident analysis of WWER 1000/B 320 LOCA DN100 computed by computer codes ASTEC V1.1 and SCDAP/RELAP5

    International Nuclear Information System (INIS)

    Kalchev, B.; Dimov, D.; Tusheva, P.; Mladenov, I.

    2005-01-01

    This paper presents the modelling approach for LOCA 100 mm sequence for WWER 1000-B 320 type of reactor with the integral ASTEC computer code and SCDAP/RELAP5 computer code. As a basic input deck the reference input file for Balakovo NPP from the released ASTEC CD has been applied. As a first part of the calculations for the SBLOCA sequence the ASTEC v1.1 modules CESAR, DIVA and CPA have been activated in a coupled mode. For SCDAP/RELAP5 calculation input deck for WWER 1000-B 320 has been applied which meant to be closer to the initial boundary conditions applied for ASTEC WWER 1000 input deck. A SBLOCA 100 mm comparison between ASTEC v1.1 and SCADAP/RELAP5 has been presented. ASTEC predicts vessel failure at 15620 s. ASTEC and SCDAP/RELAP5 give close but not similar results - this could be observed on the trends. The comparison of 100 mm-break shows that SCDAP/RELAP5 predicts clear phenomenological changes in primary pressure evolution and molten pool formation. Similar hydrogen production mass for both codes around 5000 s is detected

  8. Fuel Management of WWER-1000 Reactors of Kudankulam Nuclear Power Plant, India

    International Nuclear Information System (INIS)

    Pandey, Y.; Chauhan, A.

    2008-01-01

    Two units of WWER-1000 reactors of Russian design are under construction at Kudankulam site in India. These reactors are expected to be commissioned in 2008. The fuel management services for these reactors shall be carried out using Russian Computer codes. This paper includes a brief description of the core, fuel assembly lattice and physics modeling of the lattice and core for these reactors. Presented in this paper are the salient features of the core load pattern designs and fuel performance for 8 operating cycles of these reactors. The paper describes key improvements in the core load pattern designs to enhance the fuel utilization and its thermal behaviour. Presented in the paper are also the on site fuel management strategies with regard to fuel inventory and nuclear material accounting. A computer code for Fuel Inventory and Nuclear Material Accounting (FINMAC) has been developed for this purpose. The code FINMAC takes care of receipt of fresh fuel, flow between various accounting sub areas (ASAs), burnup or production of nuclear isotopes in the reactor cores and discharge from the reactor core. The code generates Material Balance Reports (MBRs) and Composition of Ending Inventory Reports (COEIs) as per the IAEA standards. (authors)

  9. RELAP5/MOD3.2 investigation of loss of in-house supply power for WWER 1000/320V

    International Nuclear Information System (INIS)

    Gencheva, R.; Pavlova, M.; Groudev, P.

    2001-01-01

    This paper discusses the results of the thermal-hydraulic investigations of the 'Loss of in-house supply power' accident at the Kozloduy NPP Unit 6. The RELAP5/MOD3.2 computer code has been used to stimulate the loss of in-house supply power accident in a WWER 1000 Nuclear Power Plant model. This model was developed at the Institute for Nuclear Research and Nuclear Energy for analyses of operational occurrences, abnormal events and design basis scenarios. It will provide a significant analytical capability for the Bulgarian technical specialists located at the Kozloduy NPP. The criteria used in selecting transient are: importance to safety, availability and suitability of data followed by suitability for RELAP5 code validation. The investigation of 'Loss of normal and reverse AC power' is a process that compares the analytical results obtained by RELAP5/MOD3.2 model of the WWER 1000 against experimental transient data obtained from Kozloduy NPP Unit 6. The comparisons between the RELAP5 results and the test data indicate good agreement

  10. HTGR steam generator development

    International Nuclear Information System (INIS)

    Schuetzenduebel, W.G.; Hunt, P.S.; Weber, M.

    1976-01-01

    More than 40 gas-cooled reactor plants have produced in excess of 400 reactor years of operating experience which have proved a reasonably high rate of gas-cooled reactor steam generator availability. The steam generators used in these reactors include single U-tube and straight-tube steam generators as well as meander type and helically wound or involute tube steam generators. It appears that modern reactors are being equipped with helically wound steam generators of the once-through type as the end product of steam generator evolution in gas-cooled reactor plants. This paper provides a general overview of gas-cooled reactor steam generator evolution and operating experience and shows how design criteria and constraints, research and development, and experience data are factored into the design/development of modern helically wound tube steam generators for the present generation of gas-cooled reactors

  11. Dynamic behavior structural response and capacity evaluation of the standardized WWER-1000 nuclear power plants subjected to severe loading conditions

    International Nuclear Information System (INIS)

    Ambriashvili, Y.K.; Krutzik, N.J.

    1993-01-01

    In order to verify the structural capacity of standardized WWER-1000 MW nuclear power plants, comprehensive static and dynamic analyses were performed in cooperation between Siemens and Atomenergoprojekt. The main goal of these investigations was to perform of a number of seismic analyses of standardized WWER-1000 reactor buildings on the basis of 13 given seismological inputs, taking into account the local soil conditions at 17 different sites defined by in-situ investigations. The analyses were based on appropriate mathematical models (equivalent beam models as well as detailed spatial surface element models) of the coupled vibrating structures (base structure, outer structure, containment, inner structure) and of the layered soil. The analyses were mainly performed using the indirect method (substructure method). Based on the results of the seismic analysis as well as the results of static analysis (pressure and temperature due to LOCA, dead weight, prestressing) an assessment was made of the seismic safety of the containment and the reactor building. Using a complex 3-dimensional model of the structure and the soil, the influence of the flexibility of the basement structure on the structural response was also studied. The structural analyses of the WWER-1000 reactor building led to the conclusion that its design accounts well for the main factors governing the dynamic behavior of the building. The assessment of the forces acting in the structures shows that the bearing capacity of the analyzed building structure corresponds to an earthquake intensity of about 0.2 g to 0.25 g

  12. WWER fuel: Results of post irradiation examination

    International Nuclear Information System (INIS)

    Markov, D.V.; Smirnov, V.P.; Smirnov, A.V.; Polenok, V.S.; Perepelkin, S.O.; Ivashchenko, A.A.

    2006-01-01

    Experience in the field of fabrication, operation, testing and post-irradiation examinations (PIE) made it possible to settle the following requirements for a new generation of WWER nuclear fuel: - For WWER-1000 FA, the service life is no less than 5 years, 3 alternative fuel cycles (FC): 12 months x 4 FCs, 12 months x 5 FCs and 18 months x 3 FCs; - For WWER-440 FA, fuel cycle is 12 months x 5 FCs and a part of operating assembly is left for the 6. year; - High fuel burnup - up to 70 MWd/kgU; - Dimensional stability of FA and its components; - FA repairability; - Adaptability of fuel cycles; - Maintenance of maneuvering operating conditions at the NPP; - Reliability of control rod operation; - High serviceability level - FE leakage is no worse than 10-5 l/year. In order to provide the fulfillment of the above-given requirements, designers and production engineers have worked out cumulative measures and engineering solutions, which are introduced in development of a new generation fuel. Currently old design FA-M assemblies provided with steel skeleton are being operated in WWER-1000 reactors at Ukrainian and Bulgarian NPPs. As for Russian NPPs, new-type FAs are operated. These are advanced FAs (AFA), FA-A and FA-2 provided with zirconium alloy skeletons. A design of the second generation of WWER-440 operating assemblies was developed with respect to changes in some geometrical parameters, fastening of FEs in the lower grid (splinting was substituted for collet), usage of reinforcing rib under the lower grid, anti-debris filter and hafnium elements of junction unit as well as hafnium content decrease from 0.05 % mass down to 0.01% mass in zirconium materials. They are basic designs of FAs in order to be introduced in a five-year fuel cycle of WWER-440 NPPs in Czech Republic and Slovakia since 2005 and have got prospects for development. The operating experience of dismountable operating assemblies at the Loviisa NPP, vibration-proof operating assemblies at the

  13. The IAEA extrabudgetary programme on the safety of WWER and RBMK plants

    International Nuclear Information System (INIS)

    Havel, R.

    1995-01-01

    Data on WWER-440/213, WWER-440/230, WWER-1000 and RBMK reactors in operation are presented. Organizational chart for the IAEA extrabudgetary programme on the safety of WWER and RBMK plants, general programme objectives and main components are outlined

  14. Fuel assembly leak tightness control on WWER-1000 reactor

    International Nuclear Information System (INIS)

    Ivanova, R.; Gerchev, N.; Mateev, A.

    2001-01-01

    The main index for integrity of the fuel rods cladding is the specific activity value of the primary coolant. This value determines the safe operation of the reactor. The limit for safe operation of WWER-1000 reactor is the value of the total activity of Iodine isotopes in the primary coolant 5.0x10 -3 Ci/l. The paper briefly describes the methodology for performing a fuel tightness test (sipping test) and shows the results from these tests performed during the period 1987 -1999 in units 5 and 6 at the Kozloduy NPP. An additional index related to the safe operation is defined to characterize the fuel cladding integrity Fuel Reliability Index (FRI). The FRI is defined as value of the average activity of 131 I in the primary coolant, corrected with a part of precipitated 235 U migration and fixed to the general permanent purification frequency. Two criteria (quantitative and statistic) are determined to qualify the fuel cladding integrity. The results from sipping tests show good reliability of the fuel irradiated in unit 5 and 6 at the Kozloduy NPP

  15. Steam generators and fuel engineering utilizing solid, liquid, gaseous and special fuels

    Energy Technology Data Exchange (ETDEWEB)

    Thor, G

    1983-01-01

    Provided were technological specifications and details in the design of brown coal fired steam generators, produced in the German Democratic Republic. These steam generators range in their capacity between 1.6 and more than 1,000 t/h. The appropriate coal feeding systems, water supply and cleaning equipment, coal pulverizers and ash removal units are also manufactured. Various schemes show the design of a 25 to 64 t/h, a 320 t/h and an 815 t/h brown coal steam generator. Specifications are given for series of fuel pulverizers available, for the water circulation system and steam evaporators. The VEB Dampferzeugerbau Berlin also offers steam generators for saliniferous brown coal with a steam capacity up to 125 t/h, steam generators for pulverized black coal with a capacity up to 350 t/h and oil and gas fired generators up to 250 t/h. The company has experience in combustion of biomass (sugar cane waste) with oil in steam generators of more than 100 t/h capacity, and in projecting firing systems for other biofuels including rice, peanut and coconut hulls, wood and bark. Multi-biofuel firing in combination with coal for steam generation is also regarded as possible. (In English)

  16. Calculated and experimental research of WWER-1000 assembly vibration and fretting damage

    International Nuclear Information System (INIS)

    Drozdov, Y.; Afanasyev, A.; Makarov, V.; Tutnov, A.; Tutnov, A.; Alekseev, E.

    2008-01-01

    The report covers the methods and results of the latest analytical and experimental studies of fretting corrosion and natural vibrations of a WWER-1000 reactor fuel assemblies (FA). The process of fretting-corrosion was investigated using a multi-specimen facility that simulated fragments of fuel rod-to-spacer grid and lower support grid mating units. A computational model was developed for vibrations in the mechanical system of a fuel rod fragment and a spacer grid fragment. A calculational and experimental modal analysis of a FA was performed. Natural frequencies, modes and decrements of FA vibrations were determined and a satisfactory coincidence of analytical and experimental results was obtained. The assessment of fretting-corrosion process dynamics was made and its dependences on operational factors were obtained. (authors)

  17. Measuring neutron flux density in near-vessel space of a commercial WWER-1000 reactor

    International Nuclear Information System (INIS)

    Borodkin, G.I.; Eremin, A.N.; Lomakin, S.S.; Morozov, A.G.

    1987-01-01

    Distribution of neutron flux density in two experimental channels on the reactor vessel external surface and in ionization chamber channel of a commercial WWER-1000 reactor, is measured by the activation detector technique. Azimuthal distributions of fast and thermal neutron fluxes and height distributions of fast neutron flux density within energy range >1.2 and 2.3 MeV are obtained. Conclusion is made, that reactor core state and its structural peculiarities in the measurement range essentially affect space and energy distribution of neutron field near the vessel. It should be taken into account when determining permissible neutron fluence for the reactor vessel

  18. Steam generator

    International Nuclear Information System (INIS)

    Fenet, J.-C.

    1980-01-01

    Steam generator particularly intended for use in the coolant system of a pressurized water reactor for vaporizing a secondary liquid, generally water, by the primary cooling liquid of the reactor and comprising special arrangements for drying the steam before it leaves the generator [fr

  19. Current state of WWER SNF storage in Russia and the perspectives

    International Nuclear Information System (INIS)

    Anisimov, O.; Kozlov, Y.; Razmashkin, N.; Safutin, V.; Tikhonov, N.

    2006-01-01

    In the Russian Federation WWER-440 Spent Nuclear Fuel (SNF) is reprocessed at RT-1 plant near Cheliabinsk. WWER-1000 SNF is supposed to be reprocessed at RT-2 plant, which will be built about 2020. The information on the capacity and fill up level of the at-reactor pools at NPP with WWER reactors considering its modification up to May 2005 is given. The regulatory requirements to all SNF 'wet' storage facilities; the principle design and engineering solutions as well as the complex of measures for radiation safety and the environmental protection of spent fuel storage are presented. WWER-440 SNF management, WWER-1000 SNF management and dry storage of WWER-1000 SNF are discussed. In the conclusion it is noted than neither Russia, nor any other country have the experience of construction of vault-type 'dry' storage facilities of such a capacity to store WWER-1000 SNF (9000 tU). The experience and design solutions approved earlier in creation of other dangerous facilities were used. The calculations were based on conservative assumptions allowing with a large assurance to guarantee the nuclear and radiation safety and the environmental protection. At present, a program is developed for scientific-technical support of the dry storage facility design and operation, aimed at the studies whose results will allow to optimize the taken technical decisions, simplify SNF management technology and, possibly, to reduce the cost of the storage facility itself

  20. Assessment and Management of Ageing of Major Nuclear Power Plant Components Important to Safety: Steam Generators. 2011 Update

    International Nuclear Information System (INIS)

    2011-11-01

    generator of the PWR, WWER and CANDU nuclear power plants. The objective of this report is to update and supersede IAEA-TECDOC-981 in order to provide current ageing management guidance for PWR, WWER and CANDU steam generators to all involved in the operation and regulation of nuclear power plants and thus to help ensure steam generator integrity in IAEA Member States throughout their entire service life.

  1. Results of developing and problems of further improvements for WWER-1000 FA of alternative design

    International Nuclear Information System (INIS)

    Molchanov, V.L.; Panyushkin, A.K.; Zheleznyak, V.M.; Samojlov, O.B.; Kuul', V.S.; Kurylev, V.I.

    2001-01-01

    A new fuel assembly of alternative design (FAA) is created for a WWER-1000 reactor which is characteristic of dimensional stability on operation. The FAA includes a frame of 15 alloy Eh-110 spacer grids spot welded to 6 alloy Eh-635 angle sections. In-core tests show that the FAA is stable to form changing. It is concluded that the FAA can serve as a basis for development of promising fuel cycle with high burnups, specifically, for a 4 year cycle with the use of uranium-gadolinium fuel [ru

  2. Evolution of ASTEC V1.2 rev.1 code for WWER-1000 reactors/SBO sequence

    International Nuclear Information System (INIS)

    Georgieva, J.; Stefanova, A.; Groudev, P.; Tusheva, P.; Kalchev, B.; Passalacqua, R.

    2006-01-01

    In this paper a comparison between calculations of severe accidents occurred from WWER-1000 with ASTEC code specified for an event of full unloading with relief valves stuck opened with no hydroaccumulators intervention is presented. The purpose of the analyses provided is to present the relationship between the improvements of the actual version (ASTEC Vl.2 rev. 1) and ASTEC V1.1 p2 like: code modifications, incoming data improvements. Such discrepancies are to be examined. Case by case suggestions for ASTEC improvements are to be provided

  3. Procedure for generating steam and steam generator for operating said procedure

    International Nuclear Information System (INIS)

    Chlique, Bernard.

    1975-01-01

    This invention concerns the generation of steam by bringing the water to be vaporised into indirect thermal exchange relation with the heating steam which condenses when passing in series, along alternate routes, through bundles of tubes immersed in a vaporising chamber. A number of steam generators working on this principle already exist. The purpose of the invention is to modify the operating method of these steam generators by means of a special disposition making it possible to build a compact unit including an additional bundle of tubes heated by the condensates collected at the outlet of each bundle through which the heating steam passes [fr

  4. Dynamic analysis of WWER-1000 nuclear power plants

    International Nuclear Information System (INIS)

    Asfura, A.P.; Jordanov, M.J.

    1995-01-01

    As part of the effort to assess the seismic vulnerability of nuclear power plants in Eastern Europe, a series of dynamic analyses have been carried out for several plants. These analyses were performed using modern analysis techniques, current local seismic parameters, and local soil profiles. This paper presents a compilation of some of the seismic analyses performed for the WWER-1000 reactor buildings at the nuclear power plants of Belene and Kozloduy in Bulgaria, and Temelin in the Czech Republic. The reactor buildings at these three plants are practically identical and correspond to the standard building design for this type of reactors. The series of analyses performed for these buildings encompasses various soil profiles, seismic ground motions, and different soil-structure interaction analysis techniques and modelling. The analysis of a common structure under different conditions gives the opportunity to assess the relative importance that each of the analysis elements has in the structural responses. The use of different SSI computer programs and foundation modeling was studied for Kozloduy, and the effects of different soil conditions and site-specific seismicity were studied by comparing the responses for the three plants. In-structure acceleration response spectra were selected as the structural responses for comparison purposes

  5. Development of LBB Piping Evaluation Diagram for APR 1000 Main Steam Line Piping

    International Nuclear Information System (INIS)

    Yang, J. S.; Jeong, I. L.; Park, C. Y.; Bai, S. Y.

    2010-01-01

    This paper presents the piping evaluation diagram (PED) to assess the applicability of Leak-Before- Break(LBB) for APR 1000 main steam line piping. LBB-PED of APR 1000 main steam line piping is independent of its piping geometry and has a function of the loads applied in piping system. Also, in order to evaluate LBB applicability during construction process with only the comparative evaluation of material properties between actually used and expected, the expected changes of material properties are considered in the LBB-PED. The LBB-PED, therefore, can be used for quick LBB evaluation of APR 1000 main steam line piping of both design and construction

  6. 3D PORFLO simulations of Loviisa steam generator

    International Nuclear Information System (INIS)

    Hovi, V.; Ilvonen, M.

    2010-01-01

    PORFLO is a 3-dimensional two-phase flow solver for porous media, developed at VTT originally by Jaakko Miettinen and now mainly by the author Ville Hovi. It is targeted at applications where 3D phenomena may be significant, but geometrical complexity does not allow for a CFD-style structure-fitted grid, such as steam generators and other heat exchangers, reactor cores or core debris beds. Basic features of PORFLO include staggered Cartesian grid and iterative solution of pressure and phase velocities (phase-coupled SIMPLE) based on 3D momentum equations, together with mass and energy equations, all for both liquid and vapour. A PORFLO model of the secondary side of a WWER-440 horizontal steam generator was developed and some preliminary simulations of its steady state operation were performed. To generate the necessary boundary condition on the primary tubes, an APROS system code model was used, from which a simple unidirectional transfer brings the tube surface temperatures to PORFLO. Feedwater is modelled by mass sources at the injection tube, with no consideration of its momentum. In the interphasial mass transfer, evaporation and condensation are considered in the bulk sense and due to the primary tubes. In momentum transfer, the interphasial drag and the drag caused by the tube bundles are modelled according to. Results of the PORFLO simulations presented here, typically in a 109 x 30 x 30 grid, include liquid and vapour velocities, void fractions and evaporation / condensation rates. Furthermore, some comparisons of PORFLO and Fluent results were made. (Authors)

  7. Calculation of isotope burn-up and change in efficiency of absorbing elements of WWER-1000 control and protection system during burn-up

    International Nuclear Information System (INIS)

    Timofeeva, O.A.; Kurakin, K.U.

    2006-01-01

    The report deals with fast and thermal neutron flows distribution in structural elements of WWER-1000 fuel assembly and absorbing rods, determination of absorbing isotope burn-up and worth variation in WWER reactor control and protection system rods. Simulation of absorber rod burn-up is provided using code package SAPPHIRE 9 5 end RC W WER allowing detailed description of the core segment spatial model. Maximum burn-up of absorbing rods and respective worth variation of control and protection system rods is determined on the basis of a number of calculations considering known characteristics of fuel cycles (Authors)

  8. Modelling and simulation of process control systems for WWER

    Energy Technology Data Exchange (ETDEWEB)

    Pangelov, N [Energoproekt, Sofia (Bulgaria)

    1996-12-31

    A dynamic modelling method for simulation of process control system is developed (method for identification). It is based on the least squares method and highly efficient linear uninterrupted differential equations. The method has the following advantages: there are no significant limitations in the type of input/output signals and in the length of data time series; identification at none zero initial condition is possible; on-line identification is possible; a high accuracy is observed in case of noise. On the basis of real experiments and data time series simulated with known computer codes it is possible to construct highly efficient models of different systems for solving the following problems: real time simulation with high accuracy for training purposes; estimation of immeasurable parameters important to safety; malfunction diagnostics based on plant dynamics; prediction of dynamic behaviour; control vector estimation in regime adviser. Two real applications of this method are described: in dynamic behaviour modelling for steam generator level, and in creating of a Process Control System Simulator (PCSS) based on KASKAD-2 for WWER-1000 units of the Kozloduy NPP. 6 refs., 8 figs.

  9. Express diagnostics of WWER fuel rods at nuclear power plants

    International Nuclear Information System (INIS)

    Pavlov, S.; Amosov, S.; Sagalov, S.; Kostyuchenko, A.

    2009-01-01

    Higher safety and economical efficiency of nuclear power plants (NPP) call for a continuous design modification and technological development of fuel assemblies and fuel rods as well as optimization of their operating conditions. In doing so the efficiency of new fuel introduction depends on the completeness of irradiated fuel data in many respects as well as on the rapidity and cost of such data obtaining. Standard examination techniques of fuel assemblies (FA) and fuel rods (FR) intended for their use in hot cell conditions do not satisfy these requirements in full extent because fuel assemblies require preliminary cooling at NPP to provide their shipment to the research center. Expenditures for FA transportation, capacity of hot cells and expenditures for the examined fuel handling do not make it possible to obtain important information about the condition of fuel assemblies and fuel rods after their operation. In order to increase the comprehensiveness of primary data on fuel assemblies and fuel rods immediately after their removal from the reactor, inspection test facilities are widely used for these purposes. The inspection test facilities make it possible to perform nondestructive inspection of fuel in the NPP cooling pools. Moreover these test facilities can be used to repair failed fuel assemblies. The ultrasonic testing of failed fuel rods inside the fuel assembly was developed for stands of inspection and repair of TVSA WWER-1000 for the Kalinin NPP and Temelin NPP. This method was tested for eight leaking fuel assemblies WWER-440 and WWER-1000 with a burnup of ∼14 up to 38 MW·day/kgU. The ultrasonic testing proved its high degree of reliability and efficiency. The defectoscopy by means of the pulsed eddy-current method was adapted for the stand of inspection and repair of TVSA WWER-1000 for the Kalinin NPP. This method has been used at RIAR as an express testing method of FR claddings during the post-irradiation examinations of fuel assemblies WWER

  10. Oxidation of Zircaloy-4 under limited steam supply at 1000 and 13000C

    International Nuclear Information System (INIS)

    Uetsuka, H.

    1984-12-01

    With the view of examining the oxidation behavior of Zircaloy-4 under limited steam supply occurring in severe accidents of LWRs, Zircaloy-4 cladding specimens were examined at the isothermal oxidation temperatures of 1000 and 1300 0 C under a steam atmosphere, flowing at a reduced and constant rate in the range of 3proportional170 mg/cm 2 xmin. The effect of steam starvation, which was restricted to very low levels of steam supply rate, was observed at the two examined temperatures. And the critical supply rate of steam starvation was evaluated to be 13 and 20 mg/cm 2 xmin for the oxidation at 1000 and 1300 0 C, respectively. Variation of the oxidation duration between 2 and 60 min at 1000 0 C allowed to compare the reaction kinetics for three different rates of steam supply. The short-term results confirmed the reduced reaction rates for the lower steam supplies. At the longer times, however, a clear trend towards linear kinetics was observed for the lower supplies. This can be interpreted as the result of earlier breakaway transition under limited steam supply. In the test at 1300 0 C, an acceleration of the oxidation rate was measured for the specified steam supply rate between 20 and 60 mg/cm 2 xmin. This related strongly with high hydrogen concentration in the atmosphere. Hydrogen blanketing - the retarding effect of hydrogen on Zircaloy oxidation - was not identified in the examined temperature range. (orig./HP) [de

  11. Primary collector wall local temperature fluctuations in the area of water-steam phase boundary

    Energy Technology Data Exchange (ETDEWEB)

    Matal, O.; Klinga, J.; Simo, T. [Energovyzkum Ltd., Brno (Switzerland)

    1995-12-31

    A limited number of temperature sensors could be installed at the primary collector surface in the area of water - steam phase boundary. The surface temperatures as well WWER 440 steam generator process data were measured and stored for a long time and off-line evaluated. Selected results are presented in the paper. (orig.). 2 refs.

  12. Primary collector wall local temperature fluctuations in the area of water-steam phase boundary

    Energy Technology Data Exchange (ETDEWEB)

    Matal, O; Klinga, J; Simo, T [Energovyzkum Ltd., Brno (Switzerland)

    1996-12-31

    A limited number of temperature sensors could be installed at the primary collector surface in the area of water - steam phase boundary. The surface temperatures as well WWER 440 steam generator process data were measured and stored for a long time and off-line evaluated. Selected results are presented in the paper. (orig.). 2 refs.

  13. Main trends of upgrading the 1000 MW steam turbine

    International Nuclear Information System (INIS)

    Drahy, J.

    1990-01-01

    Parameters are compared for the 1000 MW steam turbine manufactured by the Skoda Works, Czechoslovakia, and turbines in the same power range by other manufacturers, viz. ABB, Siemens/KWU, GEC and LMZ. The Skoda turbine compares well with the other turbines with respect to all design parameters, and moreover, enables the most extensive heat extraction for district heating purposes. The main trends in upgrading this turbine are outlined; in particular, they include an additional increase in the heat extraction, which is made possible by a new design of the low-pressure section or by using a ''satellite'' turbine. The studies performed also indicate that the output of the full-speed saturated steam turbine can be increased to 1300 MW. An experimental turbine representing one flow of the high-pressure part of the 1000 MW turbine is being built on the 1:1 scale. It will serve to verify the methods of calculation of the wet steam flow and to experimentally test the high-pressure part over a wide span of the parameters. (Z.M.). 1 tab., 3 figs., 7 refs

  14. In-service diagnostic systems of steam generators, pressurizers and other components of WWER type nuclear power plants

    International Nuclear Information System (INIS)

    Matal, O.

    1988-01-01

    A detailed description is presented of the systems of vibration inspections and systems of determining residual service life, implemented as in-service diagnostic systems for steam generators and pressurizers at the Dukovany nuclear power plant. Low temperature accelerometers of the KD or KS type and high temperature accelerometers CA 91 are used as vibration sensors. In the system of vibration inspection a total of 64 vibration measuring chains of Czechoslovak make and design are installed in the power plant. Systems are being built for determining residual service life which consist of 75 special chains for heat monitoring with thermocouples installed on selected assemblies of the steam generators and the pressurizers serving to monitor and evaluate heat stress. Also included in the system for determining residual service life are 16 routes for water withdrawal from steam generators. Their purpose is to make in-service determinations of places of biggest concentrations of impurities in secondary water, to determine the biggest local chemical exposure of primary collector and heat exchange tube materials and to optimize the size and place of leachate withdrawal. (Z.M.). 2 figs., 2 tabs., 15 refs

  15. Quantum behaved Particle Swarm Optimization with Differential Mutation operator applied to WWER-1000 in-core fuel management optimization

    International Nuclear Information System (INIS)

    Jamalipour, Mostafa; Sayareh, Reza; Gharib, Morteza; Khoshahval, Farrokh; Karimi, Mahmood Reza

    2013-01-01

    Highlights: ► A new method called QPSO-DM is applied to BNPP in-core fuel management optimization. ► It is found that QPSO-DM performs better than PSO and QPSO. ► This method provides a permissible arrangement for optimum loading pattern. - Abstract: This paper presents a new method using Quantum Particle Swarm Optimization with Differential Mutation operator (QPSO-DM) for optimizing WWER-1000 core fuel management. Genetic Algorithm (GA) and Particle Swarm Optimization (PSO) have shown good performance on in-core fuel management optimization (ICFMO). The objective of this paper is to show that QPSO-DM performs very well and is comparable to PSO and Quantum Particle Swarm Optimization (QPSO). Most of the strategies for ICFMO are based on maximizing multiplication factor (k eff ) to increase cycle length and minimizing power peaking factor (P q ) in order to improve fuel integrity. PSO, QPSO and QPSO-DM have been implemented to fulfill these requirements for the first operating cycle of WWER-1000 Bushehr Nuclear Power Plant (BNPP). The results show that QPSO-DM performs better than the others. A program has been written in MATLAB to map PSO, QPSO and QPSO-DM for loading pattern optimization. WIMS and CITATION have been used to simulate reactor core for neutronic calculations

  16. Influence of decontamination of the WWER-440 primary circuit equipment on pressure drop in the reactor

    International Nuclear Information System (INIS)

    Kritsky, V.; Rodionov, Y.; Beresina, I.

    2003-01-01

    Over 40 reactor cycles at four WWER-440 type reactors have been analyzed in order to explain the increase of the pressure drop under certain combination of conditions. It is shown that the staff radiation exposure and the dose rate at first circuit segments are inversely correlated with the value of the pressure drop at the reactor, which is connected with the mechanism of redistribution of deposits and radioactive nuclides between the reactor and the rest part of the circuit. The influence of pH T on the formation of the dose rate from equipment and the change of pressure drop in the reactor WWER-440 is studied. The optimal range of pH T values for these parameters is determined to be 6.95-7.05 and these values are within the range of the water chemistry standards. The correlation between the changes of pressure drop and the number of decontaminated steam generators is established. This correlation shows that the pressure drop at the reactor grows with the increase of steam generators decontaminated during a preventive maintenance

  17. Verification results of methodology for determining the weighted mean coolant temperature in the primary circuit hot legs of WWER-1000 reactor plants

    International Nuclear Information System (INIS)

    Saunin, Yuri V.; Dobrotvorski, Alexander N.; Semenikhin, Alexander V.; Korolev, Alexander S.

    2017-01-01

    The JSC ''Atomtechenergo'' experts have developed a new methodology for determining the weighted mean coolant temperature in the primary circuit hot legs of WWER-1000 reactor plants. The necessity for developing the new methodology was determined by the need to decrease the calculation error of the weighted mean coolant temperature in the hot legs because of the coolant temperature stratification. The methodology development was based on the findings of experimental and calculating research executed by the authors. The methodology verification was fulfilled through comparison of calculation results obtained with and without the methodology use in various operational states and modes of several WWER-1000 power units. The obtained verification results have confirmed that the use of the new methodology provides objective error decrease in determining the weighted mean coolant temperature in the primary circuit hot legs. The decrease value depends on the stratification character which is various for different objects and conditions.

  18. Verification results of methodology for determining the weighted mean coolant temperature in the primary circuit hot legs of WWER-1000 reactor plants

    Energy Technology Data Exchange (ETDEWEB)

    Saunin, Yuri V.; Dobrotvorski, Alexander N.; Semenikhin, Alexander V.; Korolev, Alexander S. [JSC ' ' Atomtechenergo' ' , Novovoronezh (Russian Federation). Novovoronezh Filial ' ' Novovoronezhatomtechenergo' ' ; Ryasny, Sergei I. [JSC ' ' Atomtechenergo' ' , Moscow (Russian Federation)

    2017-09-15

    The JSC ''Atomtechenergo'' experts have developed a new methodology for determining the weighted mean coolant temperature in the primary circuit hot legs of WWER-1000 reactor plants. The necessity for developing the new methodology was determined by the need to decrease the calculation error of the weighted mean coolant temperature in the hot legs because of the coolant temperature stratification. The methodology development was based on the findings of experimental and calculating research executed by the authors. The methodology verification was fulfilled through comparison of calculation results obtained with and without the methodology use in various operational states and modes of several WWER-1000 power units. The obtained verification results have confirmed that the use of the new methodology provides objective error decrease in determining the weighted mean coolant temperature in the primary circuit hot legs. The decrease value depends on the stratification character which is various for different objects and conditions.

  19. Steam generator life management

    International Nuclear Information System (INIS)

    Tapping, R.L.; Nickerson, J.; Spekkens, P.; Maruska, C.

    1998-01-01

    Steam generators are a critical component of a nuclear power reactor, and can contribute significantly to station unavailability, as has been amply demonstrated in Pressurized Water Reactors (PWRs). CANDU steam generators are not immune to steam generator degradation, and the variety of CANDU steam generator designs and tube materials has led to some unexpected challenges. However, aggressive remedial actions, and careful proactive maintenance activities, have led to a decrease in steam generator-related station unavailability of Canadian CANDUs. AECL and the CANDU utilities have defined programs that will enable existing or new steam generators to operate effectively for 40 years. Research and development work covers corrosion and mechanical degradation of tube bundles and internals, chemistry, thermal hydraulics, fouling, inspection and cleaning, as well as provision for specially tool development for specific problem solving. A major driving force is development of CANDU-specific fitness-for-service guidelines, including appropriate inspection and monitoring technology to measure steam generator condition. Longer-range work focuses on development of intelligent on-line monitoring for the feedwater system and steam generator. New designs have reduced risk of corrosion and fouling, are more easily inspected and cleaned, and are less susceptible to mechanical damage. The Canadian CANDU utilities have developed programs for remedial actions to combat degradation of performance (Gentilly-2, Point Lepreau, Bruce A/B, Pickering A/B), and have developed strategic plans to ensure that good future operation is ensured. This report shows how recent advances in cleaning technology are integrated into a life management strategy, discusses downcomer flow measurement as a means of monitoring steam generator condition, and describes recent advances in hideout return as a life management tool. The research and development program, as well as operating experience, has identified

  20. Heat transfer tube surface layers and the operating medium of WWER-440 steam generators

    International Nuclear Information System (INIS)

    Splichal, K; Krhounek, V.; Ruscak, M.; Rybka, R.

    1998-12-01

    Corrosion damage of steam generator tubes is dependent on the local secondary circuit environment parameters. The composition and morphology of the oxide and deposit layers were investigated. The liquid to solid phase ratios in slots were determined by the MULTEQ code, and the effect of changes in the various components on the aqueous medium parameters was examined. The parameters were evaluated with respect to their effect on the corrosion cracking of the austenitic steel. (author)

  1. Data base and postirradiation examination results of spent WWER-1000 fuel elements and assemblies

    International Nuclear Information System (INIS)

    Kanashov, B.A.; Polenok, V.S.; Smirnov, A.V.; Zhitelev, V.A.

    1995-01-01

    The report presents the results of the postirradiation shape change examination of standard fuel elements and fuel assemblies irradiated in standard conditions in Russian power reactors of the WWER-1000 type. The information is based on the results obtained at the Fuel Research Department of the Federal Scientific Centre Research Institute of Atomic Reactors (FSC RIAR, Dimitrovgrad, Russian Federation) within the period from 1987 to 1994. Emphasis is placed on such experimental and calculational data as: length, cross-section dimensions and shape of FAs with wrapper; change of standard FA skeleton members dimensions; fuel bundle elongation; change of the fuel cladding outer diameter; and elongation and change of the fuel stack outer diameter. (author)

  2. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  3. Nuclear and thermal power plant power ramping capability

    International Nuclear Information System (INIS)

    Golovach, E.A.

    1983-01-01

    The possibilities of step power increase by NPP and TPP units under emergency conditions of power grids operation are considered. The data analysis has shown that power units ramping capability with WWER-440, WWER-1000 and RBMK-1000 reactors is higher than that of 300 MW power units on fossil fuel, at the initial time interval (0-30 s). These NPP power units satisfy as to ramping capability the energy system requirements. Higher NPP power units ramping capability is explained by the fact that relative pressure before turbine valves is decreased less than in straight-through boilers while the steam volumes time constant of steam separator-superheaters is less than that of intermediate superheatings. Higher power unit ramping capability with WWER-440 and RBMK-1000 reactors as compared with the WWER-1000 reactor is pointed out as well as the increase of WWER-1000 power unit capability using high-speed turbines

  4. Calculations of fission rate distribution in the core of WWER-1000 mock-up on the LR-0 reactor using alternative methods and comparison with results of measurements

    International Nuclear Information System (INIS)

    Zaritskiy, S.; Kovalishin, A.; Tsvetkov, T.; Rypar, V.; Svadlenkova, M.

    2011-01-01

    General review of experimental and calculation researches on WWER-440 and WWER-1000 mock-ups on the reactor LR-0 was introduced on the twentieth Symposium AER. The experimental core fission rate distribution was obtained by means of gamma-scanning of the fuel pins - 140La single peak (1596 keV) measurements and wide energy range (approximately 600-900 keV) measurements. Altogether from 260 to 500 fuel pins were scanned in different experiments. The measurements were arranged in the middle of the fuel (the active part of pin). Pin-to-pin calculations of the WWER-1000 mock-up core fission rate distribution were performed with several codes: Monte Carlo codes MCU-REA/2 and MCNPX with different nuclear data libraries, diffusion code RADAR (63 energy groups library) and code SVL based on Surface Harmonics Method (69 energy groups). Calculated data are compared with experimental ones. The obtained results allow developing the benchmark for core calculations methodologies, evaluating and validating source reliability for the out-of-core (inside and outside pressure vessel) neutron transport calculations. (Authors)

  5. Steam generators - problems and prognosis

    International Nuclear Information System (INIS)

    Tapping, R.L.

    1997-05-01

    Steam-generator problems, largely a consequence of corrosion and fouling, have resulted in increased inspection requirements and more regulatory attention to steam-generator integrity. In addition, utilities have had to develop steam-generator life-management strategies, including cleaning and replacement, to achieve design life. This paper summarizes the pertinent data to 1993/1994, and presents an overview of current steam-generator management practices. (author)

  6. EPRI steam generator programs

    International Nuclear Information System (INIS)

    Martel, L.J.; Passell, T.O.; Bryant, P.E.C.; Rentler, R.M.

    1977-01-01

    The paper describes the current overall EPRI steam generator program plan and some of the ongoing projects. Because of the recent occurrence of a corrosion phenomenon called ''denting,'' which has affected a number of operating utilities, an expanded program plan is being developed which addresses the broad and urgent needs required to achieve improved steam generator reliability. The goal of improved steam generator reliability will require advances in various technologies and also a management philosophy that encourages conscientious efforts to apply the improved technologies to the design, procurement, and operation of plant systems and components that affect the full life reliability of steam generators

  7. Results of trial operation of the WWER advanced fuel assemblies

    International Nuclear Information System (INIS)

    Vasilchenko, I.; Dragunov, Y.; Mikhalchuk, A.

    2001-01-01

    The paper describes results from experimental operation of advanced WWER-1000 fuel assemblies (AFA) at five units in Balakovo NPP. Advanced fuel is developed according to the concept of standard WWER-1000 fuel assembly (jacket-free). The new features includes: 1) zirconium guiding channels (alloy E-635 and E-110) and spacer grids (alloy E-110); 2) integrated burnable absorber gadolinium; 3) extended service life of fuel assemblies (FA) and absorber rods (possibility of repair of FA); 4) improved adoption to reactor conditions. Some results of AFA pilot operation of a three year operation are presented and analyses of effectiveness of improvements are made concerning application of zirconium channels and grids; application of integrated burnable absorbers; extension of FA and absorbing rods service life and FA repairability. These new features of WWER-1000 fuel design allow: 1) to reduce the average fuel enrichment to the 3.77% instead of 4.31% in U-235; 2) to reduce the FA axial load in reactor hot state by 40%,; 3) increasing of fuel operation in reactor to the 30000 effective days with possibility to have a 5-year residence time in the reactor. The design of new generation FA for WWER-440 reactors involves few key changes. Fuel inventory in new fuel design is increased due to elongation of fuel stack and reducing the diameter of the central hole. Vibration stability is enhanced as a result of: no-play junction of the fuel rod with the lower grid; change of SG arrangements; strengthening of the lower grid unit; secure of the central tube in the gap. Water-uranium ration is increased. Introduction of all these kinds of modernization in a 5-year fuel cycle reduces fuel component in the energy cost to the 7%

  8. Design of SMART steam generator cassette

    International Nuclear Information System (INIS)

    Kim, Y. W.; Kim, J. I.; Jang, M. H.

    2001-01-01

    Basic design development for the steam generator to be installed in the integral reactor SMART has been performed. Optimization of the steam generator shape, determination of the basic dimension and confirmation of the structural strength have been carried out. Individual steam generator cassette can be replaced in the optimized design concept of steam generator. Shape design of the steam generator cassette has been done on the computer based on 3-D CAE strategy. The structural integrity of the developed steam generator was investigated by performing the dynamic analysis for the steam generator cassette, flow induced vibration analysis for the tube bundle, and the thermo-mechanical analysis for the module header and tube. As for the manufacturing of steam generator, the numerical and the experimental simulation have been carried to control the amount of spring back and to eliminate residual stress. SMART steam generator cassette was developed by a sequential research of the aforementioned activities

  9. WWER safety investigations on LR-0 reactor

    International Nuclear Information System (INIS)

    Mikus, J.

    2001-01-01

    A set of the measurement needed for the WWER-440 and WWER-1000 reactor lifetime assessment, verification of the methods, codes and input cross section libraries for the WWER reactor pressure vessel exposure evaluation has been performed on the LR-0 experimental reactor. The WWER Mock-ups (engineering benchmarks) has been carried out on the reactor, with the aim to investigate differential neutron spectra for reactor dosimetry purposes. Critical experiments have also been performed to determine the perturbation of the fission density distribution caused by the WWER-440 control assembly. Such assembly, partially inserted in the core, has significant influence on the space power distribution. A wide research program for sub-criticality investigations of the spent nuclear fuel storage has been realized on the LR-0 reactor. A benchmark experiment is realized on the reactor in corresponding geometry for CASTOR 440/84 container for storage and transportation of spent fuel. Critical experiments with new fuel assemblies including various burnable absorbers and different enrichments are performed. A set of critical experiments is performed using the fuel assemblies with 3,6% and 4,4% enrichment, arranged in the WWER-440 type cores with various lattice pitch. The critical high of the moderator level and the moderator level coefficient of reactivity are measured and the effect of the fuel assembly, placed in a hexagonal tube of stainless steel containing boron absorber (ATABOR - STANDARD) is investigated. The obtained results are used for the validation of the codes (MCNP, KENO and SCALE) in the frame of the contract 'Burn-up credit implementation for the storage and transport containers of the spent fuel'. Combined neutron-gamma spectra measurements in the WWER-1000 Mock-up are carried out during 2001

  10. Advances in new WWER designs to improve operation and maintenance

    International Nuclear Information System (INIS)

    Dragunov, Y.G.; Ryzhov, S.B.; Podshibiakin, A.K.; Vasilchenko, I.N.; Repin, A.I.; Nikitenko, M.P.; Konoplev, N.P.; Fil, N.S.

    2000-01-01

    Economic operational indices of WWER-type reactors show their competitiveness in all the countries where these reactors operate. Advanced WWERs being designed and constructed now have the improved characteristics of economical efficiency and are more convenient for operation and maintenance. Many technical solutions aimed at improvement of the operational performance are implemented in the design of WWER-1000/V-392 and WWER-640/V-407, and these reactors are the important basis for the nuclear power expansion in Russia. Some of these solutions are considered in the present paper. (author)

  11. Predesign of an experimental (5 to 10 MWt) disk MHD facility and prospects of commercial (1,000 MWt) MHD/steam systems

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1990-07-01

    Experimental disk MHD facilities are predesigned, and commercial-scale (1,000 MWt) MHD/steam systems are investigated. The predesigns of the disk MHD facilities indicate that enthalpy extraction is 8.7% for a 10 MWt open cycle MHD generator, and increases to 37% for a 5 MWt closed cycle MHD generator. Commercial (1,000 MWt) MHD/steam systems are studied for 4 types. Of these types, the open cycle disk MHD generator shows the lowest efficiency of 42.8%, while the closed cycle disk MHD generator the highest efficiency of 50.0%. The open cycle linear generator, although showing an efficiency of 49.4%, may be the lowest-cost type, when the necessary heat source, heat exchangers and the like are taken into consideration. For the design of superconducting magnet, it is necessary to further investigate whether the one for the test facility is applicable to the commercial systems. (NEDO)

  12. Steam generators, turbines, and condensers. Volume six

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Volume six covers steam generators (How steam is generated, steam generation in a PWR, vertical U-tube steam generators, once-through steam generators, how much steam do steam generators make?), turbines (basic turbine principles, impulse turbines, reaction turbines, turbine stages, turbine arrangements, turbine steam flow, steam admission to turbines, turbine seals and supports, turbine oil system, generators), and condensers (need for condensers, basic condenser principles, condenser arrangements, heat transfer in condensers, air removal from condensers, circulating water system, heat loss to the circulating water system, factors affecting condenser performance, condenser auxiliaries)

  13. Lessons learned from the computational simulation of thermomechanical behaviour of the WWER-1000 reactor cores: FA development and its implantation into the Balakovo NPP unit 1

    International Nuclear Information System (INIS)

    Troyanov, V.; Likhatchev, Y.; Folomeev, V.; Demishonkov, A.

    2003-01-01

    The fuel assembly is forced under operation conditions by weight and hydraulic force; hold-down force; contact transversal forces; non-uniform thermal and neutron fields; thermomechanical forces in the fuel assembly multirod structure. The fuel assembly bowing has been investigated in this work. The objective of the study is to recommend the optimal design for fuel assemblies. Calculations are made using the code TEREMOK. A new generation fuel assemblies for WWER-1000 named FA-2 are suggested. The performance of the FA- 2 has been studied. The theoretical approach and the calculation technique have been verified

  14. Report of a consultants meeting on accidents during shutdown conditions for WWER nuclear power plants. Extrabudgetary programme on the safety of WWER NPPs

    International Nuclear Information System (INIS)

    1996-07-01

    The main objectives of the meeting were to exchange information on the operational occurrences, studies performed and countermeasures taken for the accidents during shutdown for WWERs, and to define the necessity and directions of the further activities which may promote the improvement of WWER safety under shutdown conditions. The consultants have discussed some aspects concerning vulnerability of safety functions during shutdown conditions, several steps required to performed accident analysis and selected operational aspects for shutdown conditions. The discussion was supported by an evaluation of selected operational occurrences. The consultants have agreed that the discussion during the meeting in major parts is relevant to all the WWER designs (i.e. WWER-1000, WWER-440/213 and WWER-440/230). As for the plant conditions, the consultants have agreed to bound the discussion mainly by the cold shutdown and refuelling modes. Refs, figs, tabs

  15. Blind pre-analysis of the main building complex WWER-1000 Kozloduy. Comparison of analytical and experimental results obtained by explosive testing (task 8a of workplan 96/97)

    International Nuclear Information System (INIS)

    Krutzik, N.J.

    1999-01-01

    In accordance with the 96/97 workplan of the Research Programme on 'Benchmark Studies for Seismic Analysis and Testing of WWER-Type Nuclear Power Plants', blind pre analyses were prepared for the main building complex of the WWER-1000 based on given excitations derived from explosive tests. The investigations were performed by several institutions based on various mathematical models and procedures for consideration of soil-structure interaction effects, but on the same explosive test input data recently obtained. The methods of calculation and software tools used will also be different. The aim of this investigation is to validate different idealization concepts (mathematical models for the idealization of the structures and the soil) as well as investigation procedures (time domain and frequency domain analysis) and finally the software tools by comparing structural response results (time histories and response spectra). This report contains the results of the blind pre analysis performed by Siemens using an equivalent beam model of the main building of the WWER 1000. The calculations were performed by means of a frequency domain calculation

  16. Steam generators secondary side chemical cleaning at Point Lepreau using the Siemens high temperature process

    International Nuclear Information System (INIS)

    Verma, K.; MacNeil, C.; Odar, S.; Kuhnke, K.

    1997-01-01

    This paper describes the chemical cleaning of the four steam generators at the Point Lepreau facility, which was accomplished as a part of a normal service outage. The steam generators had been in service for twelve years. Sludge samples showed the main elements were Fe, P and Na, with minor amounts of Ca, Mg, Mn, Cr, Zn, Cl, Cu, Ni, Ti, Si, and Pb, 90% in the form of Magnetite, substantial phosphate, and trace amounts of silicates. The steam generators were experiencing partial blockage of broached holes in the TSPs, and corrosion on tube ODs in the form of pitting and wastage. In addition heat transfer was clearly deteriorating. More than 1000 kg of magnetite and 124 kg of salts were removed from the four steam generators

  17. Hybrid preheat/recirculating steam generator

    International Nuclear Information System (INIS)

    Lilly, G.P.

    1985-01-01

    The patent describes a hybrid preheat/recirculating steam generator for nuclear power plants. The steam generator utilizes recirculated liquid to preheat incoming liquid. In addition, the steam generator incorporates a divider so as to limit the amount of recirculating water mixed with the feedwater. (U.K.)

  18. CANDU steam generator life management

    International Nuclear Information System (INIS)

    Tapping, R.L.; Nickerson, J.; Spekkens, P.; Maruska, C.

    1998-01-01

    Steam generators are a critical component of a nuclear power reactor, and can contribute significantly to station unavailability, as has been amply demonstrated in Pressurized Water Reactors (PWRs). CANDU steam generators are not immune to steam generator degradation, and the variety of CANDU steam generator designs and tube materials has led to some unexpected challenges. However, aggressive remedial actions, and careful proactive maintenance activities, have led to a decrease in steam generator-related station unavailability of Canadian CANDUs. AECL and the CANDU utilities have defined programs that will enable existing or new steam generators to operate effectively for 40 years. Research and development work covers corrosion and mechanical degradation of tube bundles and internals, chemistry, thermalhydraulics, fouling, inspection and cleaning, as well as provision for specially tool development for specific problem solving. A major driving force is development of CANDU-specific fitness-for-service guidelines, including appropriate inspection and monitoring technology to measure steam generator condition. Longer-range work focuses on development of intelligent on-line monitoring for the feedwater system and steam generator. New designs have reduced risk of corrosion and fouling, are more easily inspected and cleaned, and are less susceptible to mechanical damage. The Canadian CANDU utilities have developed programs for remedial actions to combat degradation of performance (Gentilly-2, Point Lepreau, Bruce A/B, Pickering A/B), and have developed strategic plans to ensure that good future operation is ensured. The research and development program, as well as operating experience, has identified where improvements in operating practices and/or designs can be made in order to ensure steam generator design life at an acceptable capacity factory. (author)

  19. The decommissioning of the BR3 steam generator

    International Nuclear Information System (INIS)

    Denissen, L.

    2006-01-01

    A steam generator is a crucial component in a PWR (Pressurized Water Reactor). It is the crossing between the primary, contaminated, circuit and the secondary water-steam circuit. The heat from the primary reactor coolant loop is transferred to the secondary side in thousands of small tubes. Due to several problems in the material of those tubes, like SCC (Stress Corrosion Cracking), insufficient control in water chemistry, which can be the cause of tube leakage, more and more steam generators are replaced today. Only in Belgium, already 17 of them are replaced. The old 300 ton heavy SGs are stored at the 2 nuclear power plants of Doel and Tihange . While it was foreseen in the BR3 strategy to dismantle the steam generator (only 30 ton), we took the opportunity to search for a complete package in the decommissioning of a steam generator. The complete management consists of a decontamination of the primary side followed by the complete dismantling. The first step, the decontamination with MEDOC (water box + tube bundle) has already been achieved in 2002. It has led to an important DF (Decontamination Factor) between 100 and 1000 and an important dose rate reduction. This hard chemical decontamination process has been described earlier in the scientific report 2002 (The BR3 steam generator decontamination with the MEDOC process - M. Ponnet). The second step, the complete dismantling of the SG has been executed in 2005. With the BR3 SG, the main goal was to dismantle it in a safe way and to free release a maximum of material. We've used two cutting tools to perform the job: A HPWJC (High Pressure Water Jet Cutting) tool in combination with a hydraulic robot and a water cooled diamond cable. The last technique was done in close collaboration with the external company Husqvarna. It was important to have an idea of the performance, the efficiency of the cable and the quantity and the type of secondary waste

  20. Pressure drop-flow rate curves for single-phase steam in Combustion Engineering type steam generator U-tubes during severe accidents

    Energy Technology Data Exchange (ETDEWEB)

    Fynan, Douglas A.; Ahn, Kwang-Il, E-mail: kiahn@kaeri.re.kr

    2016-12-15

    Highlights: • Pressure drop-flow rate curves for superheated steam in U-tubes were generated. • Forward flow of hot steam is favored in the longer and taller U-tubes. • Reverse flow of cold steam is favored in short U-tubes. • Steam generator U-tube bundle geometry and tube diameter are important. • Need for correlation development for natural convention heat transfer coefficient. - Abstract: Characteristic pressure drop-flow rate curves are generated for all row numbers of the OPR1000 steam generators (SGs), representative of Combustion Engineering (CE) type SGs featuring square bend U-tubes. The pressure drop-flow rate curves are applicable to severe accident natural circulations of single-phase superheated steam during high pressure station blackout sequences with failed auxiliary feedwater and dry secondary side which are closely related to the thermally induced steam generator tube rupture event. The pressure drop-flow rate curves which determine the recirculation rate through the SG tubes are dependent on the tube bundle geometry and hydraulic diameter of the tubes. The larger CE type SGs have greater variation of tube length and height as a function of row number with forward flow of steam favored in the longer and taller high row number tubes and reverse flow favored in the short low row number tubes. Friction loss, natural convection heat transfer coefficients, and temperature differentials from the primary to secondary side are dominant parameters affecting the recirculation rate. The need for correlation development for natural convection heat transfer coefficients for external flow over tube bundles currently not modeled in system codes is discussed.

  1. Fuel rod behaviour at high burnup WWER fuel cycles

    International Nuclear Information System (INIS)

    Medvedev, A.; Bogatyr, S.; Kouznetsov, V.; Khvostov, G.; Lagovsky; Korystin, L.; Poudov, V.

    2003-01-01

    The modernisation of WWER fuel cycles is carried out on the base of complete modelling and experimental justification of fuel rods up to 70 MWd/kgU. The modelling justification of the reliability of fuel rod and fuel rod with gadolinium is carried out with the use of certified START-3 code. START-3 code has a continuous experimental support. The thermophysical and strength reliability of WWER-440 fuel is justified for fuel rod and pellet burnups 65 MWd/kgU and 74 MWd/U, accordingly. Results of analysis are demonstrated by the example of uranium-gadolinium fuel assemblies of second generation under 5-year cycle with a portion of 6-year assemblies and by the example of successfully completed pilot operation of 5-year cycle fuel assemblies during 6 years at unit 3 of Kolskaja NPP. The thermophysical and strength reliability of WWER-1000 fuel is justified for a fuel rod burnup 66 MWd/kgU by the example of fuel operation under 4-year cycles and 6-year test operation of fuel assemblies at unit 1 of Kalininskaya NPP. By the example of 5-year cycle at Dukovany NPP Unit 2 it was demonstrated that WWER fuel rod of a burnup 58 MWd/kgU ensure reliable operation under load following conditions. The analysis has confirmed sufficient reserves of Russian fuel to implement program of JSC 'TVEL' in order to improve technical and economical parameters of WWER fuel cycles

  2. Post-test investigation result on the WWER-1000 fuel tested under severe accident conditions

    International Nuclear Information System (INIS)

    Goryachev, A.; Shtuckert, Yu.; Zwir, E.; Stupina, L.

    1996-01-01

    The model bundle of WWER-type were tested under SFD condition in the out-of-pile CORA installation. The objective of the test was to provide an information on the WWER-type fuel bundles behaviour under severe fuel damage accident conditions. Also it was assumed to compare the WWER-type bundle damage mechanisms with these experienced in the PWR-type bundle tests with aim to confirm a possibility to use the various code systems, worked our for PWR as applied to WWER. In order to ensure the possibility of the comparison of the calculated core degradation parameters with the real state of the tested bundle, some parameters have been measured on the bundle cross-sections under examination. Quantitative parameters of the bundle degradation have been evaluated by digital image processing of the bundle cross-sections. The obtained results are shown together with corresponding results obtained by the other participants of this investigation. (author). 3 refs, 13 figs

  3. Steam generator water lancing

    International Nuclear Information System (INIS)

    Kamler, F.; Schneider, W.

    1992-01-01

    The tubesheet and tube support plate deposits in CANDU steam generators are notable for their hardness. Also notable is the wide variety of steam generator access situations. Because of the sludge hardness and the difficulty of the access, traditional water lancing processes which directed jets from the central tube free lane or from the periphery of the bundle have proven unsuitable. This has led to the need for some very unique inter tube water lancing devices which could direct powerful water jets directly onto the deposits. This type of process was applied to the upper broached plates of the Bruce A steam generators, which had become severely blocked. It has since been applied to various other steam generator situations. This paper describes the flexlance equipment development, qualification, and performance in the various CANDU applications. 4 refs., 2 tabs., 7 figs

  4. French steam generator design developments

    International Nuclear Information System (INIS)

    Ginier, R.; Campan, J.L.; Pontier, M.; Leridon, A.; Remond, A.; Castello, G.; Holcblat, A.; Paurobally, H.

    1986-01-01

    From the outset of the French nuclear power program, a significant R and D effort has been invested in improvement of the design and operation of Pressurized Water Reactors including a special committment to improving steam generators. The steam generator enhancement program has spawned a wide variety of specific R and D resources, e.g., low temperature hydraulic models for investigation of areas with single-phase flow, and freon-filled models for simulation of areas of steam generators experiencing two-phase flow (tube bundles and moisture separators). For the moisture separators, a large scale research program using freon-filled models and highly sophisticated instrumentation was used. Tests at reactor sites during startup of both 900 MWe and 1300 MWe have been used to validate the assumptions made on the basis of loop tests. These tests also demonstrated the validity of using freon to simulate two-phase flow conditions. The wealth of knowledge accumulated by the steam generator R and D program has been used to develop a new design of steam generators for the N4 plants. The current R and D effort is aimed at qualifying the N4 steam generator model and developing more comprehensive models. One prong of the R and D effort is the Megeve program. Megeve is a 25 MW steam generator which simulates operating conditions of the N4 model. The other prong is Clotaire, a freon-filled steam generator model which will be used to qualify thermal/hydraulic design codes used for multidimensional calculations for design of tube bundles

  5. New requirements for the WWER fuel and their consideration in designing the fuel assemblies

    International Nuclear Information System (INIS)

    Vasilchenko, I.; Ananyev, Y.

    2003-01-01

    In 2001-2002 the base designs of the new generation fuel assemblies for the WWER-440 and WWER-1000 reactors were developed. The ways of their further modernisation were defined. The present report deals with the urgent requirements and how they have been implemented in these designs. The assessment of the efficiency of new designs is carried out on the basis of the existing data of the world market on the cost of: Uranium concentrate; dividing operations; fabrication. It is additionally possible also to take into account the cost of transportation, storage and processing of the irradiated fuel including burial of wastes

  6. Verification calculations for the WWER version of the TRANSURANUS code

    International Nuclear Information System (INIS)

    Elenkov, D.; Boneva, S.; Georgieva, M.; Georgiev, S.; Schubert, A.; Van Uffelen, P.

    2006-01-01

    The paper presents part of the work performed in the study project 'Research and Development for Licensing of Nuclear Fuel in Bulgaria'. The main objective of the project is to provide assistance for solving technical questions of the fuel licensing process in Bulgaria. One important issue is the extension of the predictive capabilities of fuel performance codes for Russian-type WWER reactors. In the last decade, a series of international projects has been based on the TRANSURANUS fuel performance code: Specific models for WWER fuel have been developed and implemented in the code in the late 90's. In 2000-2003, basic verification work was done by using experimental data of nuclear fuel irradiated in WWER-440 reactors. While the present paper focuses on the analysis of WWER-1000 standard fuel under normal operating conditions, the above study project covers additional tasks: 1) Post-irradiation calculations of ramp tests performed in the DR3 test reactor of the Risoe National Laboratory (five instrumented fuel rods of the Risoe 3 dataset contained in the IFPE database) using the TRANSURANUS code; 2) Compilation of cross-section libraries for isotope evolution calculations in WWER-440 and WWER-1000 fuel assemblies using the ORIGEN-S code; 3) Analysis of current situation and needs for an extension of the curriculum in Nuclear Engineering at the Technical University of Sofia. In this paper the post-irradiation calculations of steady-state irradiation experiments with nuclear fuel for Russian-type WWER-1000 reactors, using the latest release of the TRANSURANUS code (v1m1j03)are presented. Regarding a comprehensive verification of modern fuel performance codes, the burn-up region above 40 MWd/kgU is of increasing importance. A number of new phenomena emerge at high fuel burn-up, implying the need for enlarged databases of postirradiation examinations (PIE). For one fuel assembly irradiated in a WWER-1000 reactor with a rod discharge burn-up between 50 and 55 MWd

  7. Steam generator tube integrity program

    International Nuclear Information System (INIS)

    Dierks, D.R.; Shack, W.J.; Muscara, J.

    1996-01-01

    A new research program on steam generator tubing degradation is being sponsored by the U.S. Nuclear Regulatory Commission (NRC) at Argonne National Laboratory. This program is intended to support a performance-based steam generator tube integrity rule. Critical areas addressed by the program include evaluation of the processes used for the in-service inspection of steam generator tubes and recommendations for improving the reliability and accuracy of inspections; validation and improvement of correlations for evaluating integrity and leakage of degraded steam generator tubes, and validation and improvement of correlations and models for predicting degradation in steam generator tubes as aging occurs. The studies will focus on mill-annealed Alloy 600 tubing, however, tests will also be performed on replacement materials such as thermally-treated Alloy 600 or 690. An overview of the technical work planned for the program is given

  8. Steam generator tube extraction

    International Nuclear Information System (INIS)

    Delorme, H.

    1985-05-01

    To enable tube examination on steam generators in service, Framatome has now developed a process for removing sections of steam generator tubes. Tube sections can be removed without being damaged for treating the tube section expanded in the tube sheet

  9. International examples of steam generator replacement

    International Nuclear Information System (INIS)

    Wiechmann, K.

    1993-01-01

    Since 1979-1980 a total of twelve nuclear power plants world-wide have had their steam generators replaced. The replacement of the Combustion steam generators in the Millstone-2 plant in the United States was completed very recently. Steam generator replacement activities are going on at present in four plants. In North Anna, the steam generators have been under replacement since January 1990. In Japan, preparations have been started for Genkai-1. Since January 1992, the two projects in Beznau-1, Switzerland, and Doel-3, Belgium, have bee planned and executed in parallel. Why steam generator replacement? There are a number of defect mechanisms which give rise to the need for early steam generator replacement. One of the main reasons is the use of Inconel-600 as material for the heating tubes. Steam generator heating tubes made of Inconel-600 have been known to exhibit their first defects due to stress corrosion cracking after less than one year of operation. (orig.) [de

  10. Cheaper power generation from surplus steam generating capacities

    International Nuclear Information System (INIS)

    Gupta, K.

    1996-01-01

    Prior to independence most industries had their own captive power generation. Steam was generated in own medium/low pressure boilers and passed through extraction condensing turbines for power generation. Extraction steam was used for process. With cheaper power made available in Nehru era by undertaking large hydro power schemes, captive power generation in industries was almost abandoned except in sugar and large paper factories, which were high consumers of steam. (author)

  11. Fuel pin failure root causes and power distribution gradients in WWER cores

    International Nuclear Information System (INIS)

    Mikus, J.

    2008-01-01

    The purpose of this work is to investigate the influence of some core heterogeneities and reactor construction materials on space power distribution in WWER type cores, especially from viewpoint of the values and gradient occurrence that could result in static loads with some consequences, e.g., fuel pin (FP) or fuel assembly (FA) bowing and possible contribution to the FP failure root causes. Presented information were obtained by means of experiments on research reactor LR-0 concerning the: 1) Power distribution estimation on pellet surface of the FPs neighbouring a FP containing gadolinium (Gd 2 O 3 ) burnable absorber integrated into fuel in WWER-440 and -1000 type cores; 2) Power distribution measurement in periphery FAs neighbouring the baffle in WWER-1000 type cores and 3) Power distribution in FAs neighbouring the control rod absorbing part in a WWER-440 type core. (author)

  12. Upgrading of WWER-1000 NPP safety on spent fuel transportation

    International Nuclear Information System (INIS)

    Kostarev, V.; Shchukin, A.; Petrenya, Yu.; Nikitin, V.; Romanovskij-Romanko, A.; Shevchenko, V.

    2003-01-01

    Transportation process for the WWER-1000 spent fuel assemblies consists of three main steps: (i) lifting of unloaded cask on the elevation of +38.05 m; (ii) loading of spent fuel assemblies into the cask; (iii) loaded cask lowering to the conveyer located in the transport corridor on the elevation 0.00 m. The most hazardous situation within described process for the cask itself and reactor building structures is an accidental drop of the cask from the height of 38.05 m to the transport corridor floor due to failure of traverse or crane's cable break. According to international practice and standards' requirements the cask shall be designed for the drop from 9 meters height to a rigid plate. However, preliminary analyses have shown that in case of 38 m drop the value of g-loads are several times larger than allowable limits. Additionally, strength capacity of the foundation slab of the reactor building is not guaranteed. Using of special damping device that is capable to bring dynamic loads to allowable limits could mitigate the catastrophic consequences of cask's 38.05 meters drop. The paper presents a basic design of the special damping platform and discusses results of analyses of different modes of cask drops and efficiency of the proposed solution. (author)

  13. Modernization of the WWER 440/230 nuclear power plant environmental protection system

    Energy Technology Data Exchange (ETDEWEB)

    Mikheev, N.V.; Kamenskaya, A.N.; Kulyukhin, S.A.; Novichenko, V.L.; Rumer, I.A. [Russian Academy of Sciences, Institute of Physical Chemistry, Moscow (Russian Federation); Antonov, B.V.; Kornienko, A.G.; Meshkov, V.M.; Rogov, M.F. [Rosenergoatom Concern, Moscow (Russian Federation)

    2001-07-01

    The papers reports a new approach to the problem of increasing environmental protection during severe accidents at WWER 440/230 nuclear power plants. The environmental protection system that we propose has three, not two protection levels, and can be introduced with minor modernization of the equipment available at WWER 440/230 nuclear power plants: 1. a jet-vortex condenser; 2. the sprinkler system; 3. a sorption module. The proposed modernization not only makes it possible to avoid emergency discharge of radioactive air and steam mix into the environment under any accident scenario, but also would substantially contribute to the safety of WWER 440/230 nuclear power plants. (author)

  14. Reactor noise analysis applications and systems in WWER-440 and WWER-1000 type PWRs

    International Nuclear Information System (INIS)

    Por, G.

    1998-01-01

    This paper presents an introduction on different types of well selected noise diagnostic methods with their occurrence in WWER reactors with an analysis of their impact on operational safety and aging which affects the installations safety as well. The main objective is to attract the attention of NPP management staff dealing with safety, safety culture, maintenance, operation and quality assurance proving that such methods can give benefit not only to economy but impact safety of nuclear installations

  15. District heating by the Bohunice nuclear power plant

    International Nuclear Information System (INIS)

    Metke, E.; Skvarka, P.

    1984-01-01

    Technical and economical aspects of district heating by the electricity generating nuclear plants in Czechoslovakia are discussed. As a first stage of the project, 240 MW thermal power will be supplied using bleeding lines steam from the B-2 nuclear power plant at Jaslovske Bohunice to heat up water at a central station to 130 grad C. The maximal thermal power that can be produced for district heating by WWER type reactors with regular condensation turbines is estimated to be: 465 MW for a WWER-440 reactor with two 220 MWe turbines and 950 MW for a WWER-1000 reactor with a Skoda made 1000 MWe turbine using a three-stage scheme to heat up water from 60 grad C to 150 grad C. The use of satelite heating turbines connected to the steam collector is expected to improve the efficiency. District heating needs will de taken into account for siting of the new power plants

  16. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 2. Generic material: Codes, standards, criteria. Working material

    International Nuclear Information System (INIS)

    1995-01-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains reports related to generic material, namely codes, standards and criteria for benchmark analysis

  17. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 2. Generic material: Codes, standards, criteria. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains reports related to generic material, namely codes, standards and criteria for benchmark analysis.

  18. Structural steels for power generating equipment and heat and chemical heat treatments

    International Nuclear Information System (INIS)

    Astaf'ev, A.A.

    1979-01-01

    Development of structural steels for power generating equipment and for reactor engineering, in particular, is elucidated. Noted is utilization of the 15Kh2NMFA steels for the WWER-1000 reactor vessels, the 10GN2MFA steels for steam generators, pressurizers, vessels of the automatic emergency shut down and safety system; the 00Kh12N3DL steel for cast pump vessels and main locking bars. The recommendations on heat treatment of big forgings, for instance, ensuring the necessary complex of mechanical properties are given. Diffusion chromizing with subsequent nitriding of austenitic steels which increase durability of the components in BN reactors more than 4 times, is practised on a large scale

  19. Diagnostic system of steam generator, especially molten metal heated steam generator

    International Nuclear Information System (INIS)

    Matal, O.; Martoch, J.

    1986-01-01

    A diagnostic system is described and graphically represented consisting of a leak detector, a medium analyzer and sensors placed on the piping connected to the indication sections of both tube plates. The advantage of the designed system consists in the possibility of detecting tube failure immediately on leak formation, especially in generators with duplex tubes. This shortens the period of steam generator shutdown for repair and reduces power losses. The design also allows to make periodical leak tests during planned steam generator shutdowns. (A.K.)

  20. Steam generator with perfected dryers

    International Nuclear Information System (INIS)

    Fenet, J.C.

    1987-01-01

    This steam generator has vertically superposed array of steam dryers. These dryers return the steam flow of 180 0 . The return of the water is made by draining channels to the steam production zone [fr

  1. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 4A. Paks NPP: Analysis/testing. Working material

    International Nuclear Information System (INIS)

    1995-01-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains reports on data related to seismic analyses of structures of Paks and Kozloduy reactor buildings and WWER-440/213 primary coolant loops with different antiseismic devices

  2. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 4A. Paks NPP: Analysis/testing. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains reports on data related to seismic analyses of structures of Paks and Kozloduy reactor buildings and WWER-440/213 primary coolant loops with different antiseismic devices.

  3. Steam generator reliability improvement project

    International Nuclear Information System (INIS)

    Blomgren, J.C.; Green, S.J.

    1987-01-01

    Upon successful completion of its research and development technology transfer program, the Electric Power Research Institute's Steam Generator Owners Group (SGOG II) will disband in December 1986 and be replaced in January 1987 by a successor project, the Steam Generator Reliability Project (SGRP). The new project, funded in the EPRI base program, will continue the emphasis on reliability and life extension that was carried forward by SGOG II. The objectives of SGOG II have been met. Causes and remedies have been identified for tubing corrosion problems, such as stress corrosion cracking and pitting, and steam generator technology has been improved in areas such as tube wear prediction and nondestructive evaluation (NDE). These actions have led to improved reliability of steam generators. Now the owners want to continue with a centrally managed program that builds on what has been learned. The goal is to continue to improve steam generator reliability and solve small problems before they become large problems

  4. Steam generator reliability improvement project

    International Nuclear Information System (INIS)

    Blomgren, J.C.; Green, S.J.

    1987-01-01

    Upon successful completion of its research and development technology transfer program, the Electric Power Research Institute's (EPRI's) Steam Generator Owners Group (SGOG II) will disband in December 1986, and be replaced in January 1987, by a successor project, the Steam Generator Reliability Project (SGRP). The new project, funded in the EPRI base program, will continue to emphasize reliability and life extension, which were carried forward by SGOG II. The objectives of SGOG II have been met. Causes and remedies have been identified for tubing corrosion problems such as stress corrosion cracking and pitting, and steam generator technology has been improved in areas such as tube wear prediction and nondestructive evaluation. These actions have led to improved reliability of steam generators. Now the owners want to continue with a centrally managed program that builds on what has been learned. The goal is to continue to improve steam generator reliability and to solve small problems before they become large problems

  5. Effect of burnup history by moderator density on neutron-physical characteristics of WWER-1000 core

    International Nuclear Information System (INIS)

    Ovdiienko, I.; Kuchin, A.; Khalimonchuk, V.; Ieremenko, M.

    2011-01-01

    Results of assessment of burnup history effect by moderator density on neutron physical characteristics of WWER-1000 core are presented on example of stationary fuel loading with Russian design fuel assembly TWSA and AER benchmark for Khmelnitsky NPP that was proposed by TUV and SSTC NRC at nineteenth symposium. Assessment was performed by DYN3D code and cross section library sets generated by HELIOS code. Burnup history was taken into account by preparing of numerous cross section sets with different isotopic composition each of which was obtained by burning under different moderator density. For analysis of history effect 20 cross section sets were prepared for each fuel assembly corresponded to each of 20 axial layers of reactor core model for DYN3D code. Four fuel cycles were modeled both for stationary fuel loading with TWSA and AER benchmark for Khmelnitsky NPP to obtain steady value of error due to neglect of burnup history effect. Main attention of study was paid to effect of burnup history by moderator density to axial power distribution. Results of study for AER benchmark were compared with experimental values of axial power distribution for fuel assemblies of first, second, third and fourth year operation. (Authors)

  6. 49 CFR 229.105 - Steam generator number.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Steam generator number. 229.105 Section 229.105..., DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Safety Requirements Steam Generators § 229.105 Steam generator number. An identification number shall be marked on the steam generator's...

  7. LMFBR steam generator development: duplex bayonet tube steam generator. Volume II

    International Nuclear Information System (INIS)

    DeFur, D.D.

    1975-04-01

    This report represents the culmination of work performed in fulfillment of ERDA Contract AT(11-1)-2426, Task Agreement 2, in which alternate steam generator designs were developed and studied. The basic bayonet tube generator design previously developed by C-E under AEC Contract AT(11-1)-3031 was expanded by incorporating duplex heat transfer tubes to enhance the unit's overall safety and reliability. The effort consisted of providing and evaluating conceptual designs of the evaporator, superheater and reheater components for a large plant LMFBR steam generator (950 MWt per heat transport loop)

  8. First generation WWER 440 - What is the 'reasonable' price?

    International Nuclear Information System (INIS)

    Pishtuhina, K.

    2004-01-01

    A chronological review of the international nuclear concerns and Three Mile Island and Chernobyl accidents effects on the international nuclear organizations' policies are presented. The IAEA, G 7 and EU approaches for Soviet design plants' safety and the main results from their implementation are described. The premature closure of the first generation WWER type reactors operated in Bulgaria, Lithuania and Slovakia and their unupgradability at a reasonable price are also discussed in this paper

  9. Informational system to assist decision making at spent nuclear fuel transportation from VVER-440, VVER-1000 and RBMK-1000 nuclear power plants

    International Nuclear Information System (INIS)

    Kuryndin, A.V.; Kirkin, A.M.; Stroganov, A.A.

    2012-01-01

    The developed informational system provides an automated estimations of nuclear and radiation safety parameters during spent nuclear fuel transportation from WWER-440 and WWER-1000 and RBMK-1000 nuclear power plants to the nuclear fuel cycle facilities, and allows us to determine the optimum cask loading from the dose rates distribution outside of protection point of view [ru

  10. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 5B. Experience data. Working material

    International Nuclear Information System (INIS)

    1996-01-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains reports on the effects of Armenia earthquakes on selected power, industry and commercial facilities and seismic functional qualification of active mechanical and electrical components tested on shaking table

  11. Databases on safety issues for WWER and RBMK reactors. Users' manual. A publication of the extrabudgetary programme on the safety of WWER and RBMK nuclear power plants

    International Nuclear Information System (INIS)

    1996-04-01

    At the beginning of the IAEA Extrabudgetary Programme on the safety of WWER reactors a great number of findings and recommendations (safety items) were collected as a result of design review and safety review missions of the WWER-440/230 type reactors. On the basis of these findings a technical database containing more than 1300 records was established to support the consolidation of the information obtained and to help in identification of safety issues. After the scope of the WWER extrabudgetary programme was extended similar data sets were prepared for the WWER-440/213, WWER-1000 and RBMK nuclear power plants. This publication describes the structure of the databases on safety issues of WWER and RBMK NPPs, the information sources used in the databases and interrogation capabilities for users to obtain the necessary information. 14 refs, 9 figs, 5 tabs

  12. Steam generator operation and maintenance

    International Nuclear Information System (INIS)

    Lee, C.K.

    2004-01-01

    Corrosion of steam generator tube has resulted in the need for extensive repair and replacement of steam generators. Over the past two decades, steam generator problems in the United States were viewed to be one of the most significant contributor to lost generation in operating PWR plants. When the SGOG-I (Steam Generator Owners Groups) was formed in early 1977, denting was responsible for almost 90% of the tube plugging. By the end of 1982, this figure was reduced to less than 2%. During the existence of SGOG-II (from 1982 to 1986), IGA/SCC (lntergranular Attack/Stress Corrosion Cracking) in the tube sheet, primary side SCC, pitting, and fretting surfaced as the primary causes of tube degradation. Although significant process has been made with wastage and denting, the utilities experience shows that the percentage of reactors plugging tubes and the percentage of tubes being plugged each year has remained relatively constant. The diversity of the damage mechanisms means that no one solution is likely to resolve all problems. The task of maintaining steam generator integrity continues to be formidable and challenging. As the older problems were brought under control, many new problems emerged. SGOG-II (Steam Generator Owners Group program from 1982 to 1986) has focused on these problem areas such as tube stress corrosion cracking (SCC) and intergranular attack (IGA) in the open tube sheet crevice, primary side tube cracking, pitting in the lower span, and tube fretting in preheated section and anti-vibration bar (AVB) locations. Primary Water Stress Corrosion Cracking (PWSCC) in the tube to tubesheet roll transition has been a wide spread problem in the Recirculation Steam Generators (RSG) during this period. Although significant progress has been made in resolving this problem, considerable work still remains. One typical problem in the Once Through Steam Generator (OTSG) was the tube support plate broached hole fouling which affects the OTSG steam generating

  13. Innovation of genetic algorithm code GenA for WWER fuel loading optimization

    International Nuclear Information System (INIS)

    Sustek, J.

    2005-01-01

    One of the stochastic search techniques - genetic algorithms - was recently used for optimization of arrangement of fuel assemblies (FA) in core of reactors WWER-440 and WWER-1000. Basic algorithm was modified by incorporation of SPEA scheme. Both were enhanced and some results are presented (Authors)

  14. Options for Steam Generator Decommissioning

    International Nuclear Information System (INIS)

    Krause, Gregor; Amcoff, Bjoern; Robinson, Joe

    2016-01-01

    Selecting the best option for decommissioning steam generators is a key consideration in preparing for decommissioning PWR nuclear power plants. Steam Generators represent a discrete waste stream of large, complex items that can lend themselves to a variety of options for handling, treatment, recycling and disposal. Studsvik has significant experience in processing full size Steam Generators at its metal recycling facility in Sweden, and this paper will introduce the Studsvik steam generator treatment concept and the results achieved to date across a number of projects. The paper will outline the important parameters needed at an early stage to assess options and to help consider the balance between off-site and on-site treatment solutions, and the role of prior decontamination techniques. The paper also outlines the use of feasibility studies and demonstration projects that have been used to help customers prepare for decommissioning. The paper discusses physical, radiological and operational history data, Pro and Contra factors for on- and off-site treatment, the role of chemical decontamination prior to treatment, planning for off-site shipments as well as Studsvik experience This paper has an original focus upon the coming challenges of steam generator decommissioning and potential external treatment capacity constraints in the medium term. It also focuses on the potential during operations or initial shut-down to develop robust plans for steam generator management. (authors)

  15. Liquid metal steam generator

    International Nuclear Information System (INIS)

    Wolowodiuk, W.

    1975-01-01

    A liquid metal heated steam generator is described which in the event of a tube failure quickly exhausts out of the steam generator the products of the reaction between the water and the liquid metal. The steam is generated in a plurality of bayonet tubes which are heated by liquid metal flowing over them between an inner cylinder and an outer cylinder. The inner cylinder extends above the level of liquid metal but below the main tube sheet. A central pipe extends down into the inner cylinder with a centrifugal separator between it and the inner cylinder at its lower end and an involute deflector plate above the separator so that the products of a reaction between the liquid metal and the water will be deflected downwardly by the deflector plate and through the separator so that the liquid metal will flow outwardly and away from the central pipe through which the steam and gaseous reaction products are exhausted. (U.S.)

  16. Circumferential cracking of steam generator tubes

    International Nuclear Information System (INIS)

    Karwoski, K.J.

    1997-04-01

    On April 28, 1995, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 95-03, open-quote Circumferential Cracking of Steam Generator Tubes.close-quote GL 95-03 was issued to obtain information needed to verify licensee compliance with existing regulatory requirements regarding the integrity of steam generator tubes in domestic pressurized-water reactors (PWRs). This report briefly describes the design and function of domestic steam generators and summarizes the staff's assessment of the responses to GL 95-03. The report concludes with several observations related to steam generator operating experience. This report is intended to be representative of significant operating experience pertaining to circumferential cracking of steam generator tubes from April 1995 through December 1996. Operating experience prior to April 1995 is discussed throughout the report, as necessary, for completeness

  17. Steam generator sludge removal apparatus

    International Nuclear Information System (INIS)

    Schafer, B.W.; Werner, C.E.; Klahn, F.C.

    1992-01-01

    The present invention relates to equipment for cleaning steam generators and in particular to a high pressure fluid lance for cleaning sludge off the steam generator tubes away from an open tube lane. 6 figs

  18. Modal analysis of spent fuel cask for WWER-1000 reactors

    International Nuclear Information System (INIS)

    Azimfar, S. A.; Kazemi, A.

    2011-01-01

    The Spent Fuel Assemblies of WWER-1000 reactors are planned to be transported by special containers which are supposed to be designed in a manner to stand against vibrations and impacts in order to protect the spent fuel from any possible damage. The vibration opposition of these containers shall be far beyond the critical resonance, because the resonances about the natural frequency of the structure will cause the enhancement of its oscillation range and may end with its disintegration. Determination of the amounts of natural frequencies and their mode shape can be achieved by vibration analyzing methods. The amount of the natural frequency of any structure crucially depends on its shape, material and lean points as well as the amount of the loads and the type of these loads. Due to the fact that the Spent Fuel Casks used for transportation in nuclear power plants in Russian Federation are TK-13 type and the pieces of information released are negligible, the scientists in Russia are working on the design and analysis of a new type made up of composite Material. In the presented paper the cask of spent fuel of TK-13 is modeled by ANSYS at 10.0 and ten natural frequency modes have been calculated, followed by the comparison of this result with the composite cask.

  19. On the method of heat exchange calculation for critical and postcritical regimes in sodium-water steam generators

    International Nuclear Information System (INIS)

    Khudasko, V.V.; Kardash, D.Yu.; Grachev, N.S.

    1986-01-01

    Technique for calculating heat exchange in sodium-water steam generators with provisions for steam-water flow non-equilibrium character and moisture additional evaporation in pipes is suggested. Zone of heat exchange crisis representing the zone of transition from developed boiling to postcritical zone is considered. Comparison of estimated and experimental data performed for the following ranges of steame generator parameters: pressure p=7.8-14.0 MPa, coolant flow rate ρw=350-1000 kg/(m 2 xs), inlet sodium temperature T=590-825 K shows their good agreement

  20. Advanced technologies on steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Sakata, Kaoru; Nakamura, Yuuki [Mitsubishi Heavy Industry Co., Takasago (Japan); Nakamori, Nobuo; Mizutani, Toshiyuki; Uwagawa, Seiichi; Saito, Itaru [Mitsubishi Heavy Industry Co., Kobe (Japan); Matsuoka, Tsuyoshi [Mitsubishi Heavy Industry Co., Yokohama (Japan)

    1997-12-31

    The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermalhydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (orig.). 3 refs.

  1. Advanced technologies on steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Sakata, Kaoru; Nakamura, Yuuki [Mitsubishi Heavy Industry Co., Takasago (Japan); Nakamori, Nobuo; Mizutani, Toshiyuki; Uwagawa, Seiichi; Saito, Itaru [Mitsubishi Heavy Industry Co., Kobe (Japan); Matsuoka, Tsuyoshi [Mitsubishi Heavy Industry Co., Yokohama (Japan)

    1998-12-31

    The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermalhydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (orig.). 3 refs.

  2. Calculational results for radiation embrittlement of WWER pressure vessel at the Kozloduy NPP

    Energy Technology Data Exchange (ETDEWEB)

    Apostolov, T; Ilieva, K; Petrova, T [Bylgarska Akademiya na Naukite, Sofia (Bulgaria). Inst. za Yadrena Izsledvaniya i Yadrena Energetika

    1996-12-31

    Determination of radiation impact on metal state in the case of WWER-440/230 is made only by calculation methods since a special sample-witness (SW) incorporation had not been implemented. In WWER-1000 reactors such SW are foreseen but their spots are high above the active core. This is why in both reactors the appliance of a calculational procedure for radiation embrittlement determination is compulsory. The authors propose such a procedure accounting for the change in critical temperature of neutron brittleness by the neutron fluence. The neutron fluence and the shift of critical embrittlement temperature have been calculated for the maximum overloaded location and for the weld metal of the Kozloduy-5 and Kozloduy-6 reactors (WWER-1000). The shift of critical temperature in weld 4 of the Units 1-4 (WWER-440) is plotted versus work cycles and compared to experimental values. 4 figs., 5 tabs.

  3. Computer simulation of WWER - 440 normal and emergency transient operating conditions

    International Nuclear Information System (INIS)

    Izbeshesku, M.; Rajka, V.; Untaru, S.; Dumitresku, A.; Paneh, M.; Turku, I.

    1976-01-01

    Results of computer realization of a model for studying transient process in the nuclear system of vapour production at the WWER - 40 peactor nuclear power plant are presented. The first circuit model consists of a number of modules, corresponding to its main parts: for each module derived were the equations describing neutron and thermohydraulic parameters. The second circuit effect is taken into account by heat quantity accepted from a steam generator. The equations are mostly differential with constant coefficients. Coefficient values and initial values of physical quantities are evaluated according to the technical literature. Both manual and automatic operations are modelled [ru

  4. Steam generating system in LMFBR type reactors

    International Nuclear Information System (INIS)

    Kurosawa, Katsutoshi.

    1984-01-01

    Purpose: To suppress the thermal shock loads to the structures of reactor system and secondary coolant system, for instance, upon plant trip accompanying turbine trip in the steam generation system of LMFBR type reactors. Constitution: Additional feedwater heater is disposed to the pipeway at the inlet of a steam generator in a steam generation system equipped with a closed loop extended from a steam generator by way of a gas-liquid separator, a turbine and a condensator to the steam generator. The separated water at high temperature and high pressure from a gas-liquid separator is heat exchanged with coolants flowing through the closed loop of the steam generation system in non-contact manner and, thereafter, introduced to a water reservoir tank. This can avoid the water to be fed at low temperature as it is to the steam generator, whereby the thermal shock loads to the structures of the reactor system and the secondary coolant system can be suppressed. (Moriyama, K.)

  5. Neutron flux uncertainty and covariances for spectrum adjustment and estimation of WWER-1000 pressure vessel fluences

    International Nuclear Information System (INIS)

    Boehmer, Bertram

    2000-01-01

    Results of estimation of the covariance matrix of the neutron spectrum in the WWER-1000 reactor cavity and pressure vessel positions are presented. Two-dimensional calculations with the discrete ordinates transport code DORT in r-theta and r-z-geometry used to determine the neutron group spectrum covariances including gross-correlations between interesting positions. The new Russian ABBN-93 data set and CONSYST code used to supply all transport calculations with group neutron data. All possible sources of uncertainties namely caused by the neutron gross sections, fission sources, geometrical dimensions and material densities considered, whereas the uncertainty of the calculation method was considered negligible in view of the available precision of Monte Carlo simulation used for more precise evaluation of the neutron fluence. (Authors)

  6. Thermal hydraulic studies in steam generator test facility

    International Nuclear Information System (INIS)

    Vinod, V.; Suresh Kumar, V.A.; Noushad, I.B.; Ellappan, T.R.; Rajan, K.K.; Rajan, M.; Vaidyanathan, G.

    2005-01-01

    Full text of publication follows: A 500 MWe fast breeder reactor is being constructed at Kalpakkam, India. This is a sodium cooled reactor with two primary and two secondary sodium loops with total 8 steam generators. The typical advantage of fast breeder plants is the high operating temperature of steam cycles and the high plant efficiency. To produce this high pressure and high temperature steam, once through straight tube vertical sodium heated steam generators are used. The steam is generated from the heat produced in the reactor core and being transported through primary and secondary sodium circuits. The steam generator is a 25 m high middle supported steam generator with expansion bend and 23 m heat transfer length. Steam Generator Test Facility (SGTF) constructed at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam aims at performing various tests on a 5.5 MWt steam generator. This vertically simulated test article is similar in all respects to the proposed 157 MWt steam generator module for the Prototype Fast Breeder Reactor (PFBR), with reduced number of tubes. Heat transfer performance tests are done with this 19 tube steam generator at various load conditions. Sodium circuit for the SGTF is equipped with oil fired heater as heat source and centrifugal sodium pump, to pump sodium at 105 m 3 /hr flow rate. Other typical components like sodium to air heat exchanger, sodium purification system and hydrogen leak detection system is also present in the sodium circuit. High pressure steam produced in the steam generator is dumped in a condenser and recycled. Important tests planned in SGTF are the heat transfer performance test, stability test, endurance test and performance test of steam generator under various transients. The controlled operation of steam generator will be studied with possible control schemes. A steady state simulation of the steam generator is done with a mathematical model. This paper gives the details of heat transfer

  7. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 4B. Paks NPP: Analysis/testing. Working material

    International Nuclear Information System (INIS)

    1995-01-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains reports on dynamic study of the main building of the Paks NPP; shake table investigation at Paks NPP and the Final report of the Co-ordinated Research Programme

  8. Anticipated transients without scram for WWER reactors. A publication of the extrabudgetary programme on the safety of WWER and RBMK nuclear power plants

    International Nuclear Information System (INIS)

    1999-12-01

    Anticipated transients without scram (ATWS) are anticipated operational occurrences followed by the failure of one reactor scram function. Current international practice requires that the capability of pressurized water reactors (PWRs) to cope with ATWS be demonstrated following a systematic evaluation of plants' defence in depth. Countries operating PWRs require design consideration of ATWS events on a deterministic basis. The regulatory requirements may concern either specific mitigating systems or acceptable plant performance during these events. The prevailing international practice for performing transient analysis of ATWS for licensing is the best estimate approach. Available transient analyses of ATWS events indicate that WWER reactors, like PWRs, have the tendency to shut themselves down if the inherent nuclear feedback is sufficiently negative. Various control and limitation functions of the WWER plants also provide a degree of defence against ATWS. However, for most WWER plants, complete and systematic ATWS analyses have yet to be submitted for rigorous review by the regulatory authorities and preventive or mitigative measures have not been established. In addition, it has also been recognized that plant behaviour in case of ATWS also relies on certain system functions (use of pressurizer safety valves for liquid discharge, availability of steam dump valve to both the condenser (BRU-K) and the atmosphere (BRU-A) for secondary side pressure control, and others) which have been identified as safety issues and need to be qualified for accident conditions. In all countries operating WWERs, the need for ATWS investigations is recognized and reflected in the safety improvement programmes. ATWS analysis for WWERs is not required for the licensing process in Bulgaria, the Czech Republic (with the exception of the Temelin nuclear power plant) and Russia. Design consideration of ATWS is required if expert assessments of probabilistic safety assessment (PSA) results

  9. Maintenance of nuclear power plants

    International Nuclear Information System (INIS)

    Lashgari, Farbod.

    1995-01-01

    This paper is about maintenance of nuclear power plants. In part one, the outage management of nuclear power plants has described. Meaning of the outage and objectives of outage management is given in introduction. The necessity of a long-term outage strategy is shown in chapter one. The main parts of an outage are as follows: Planning; Preparation; Execution, Each of them and also post-outage review have been explained in the followed chapters. Part two deals with technical details of main primary components of nuclear power plant type WWER. After an introduction about WWER reactors, in each chapter first the general and detailed description of main primary components has given and then their maintenance schedules and procedures. Chapter about reactor and steam generator is related to both types of WWER-440 and WWER-1000, but chapter about reactor coolant pump has specified to WWER-1000 to be more in details.(author)

  10. Steam generator tube rupture (SGTR) scenarios

    International Nuclear Information System (INIS)

    Auvinen, A.; Jokiniemi, J.K.; Laehde, A.; Routamo, T.; Lundstroem, P.; Tuomisto, H.; Dienstbier, J.; Guentay, S.; Suckow, D.; Dehbi, A.; Slootman, M.; Herranz, L.; Peyres, V.; Polo, J.

    2005-01-01

    The steam generator tube rupture (SGTR) scenarios project was carried out in the EU 5th framework programme in the field of nuclear safety during years 2000-2002. The first objective of the project was to generate a comprehensive database on fission product retention in a steam generator. The second objective was to verify and develop predictive models to support accident management interventions in steam generator tube rupture sequences, which either directly lead to severe accident conditions or are induced by other sequences leading to severe accidents. The models developed for fission product retention were to be included in severe accident codes. In addition, it was shown that existing models for turbulent deposition, which is the dominating deposition mechanism in dry conditions and at high flow rates, contain large uncertainties. The results of the project are applicable to various pressurised water reactors, including vertical steam generators (western PWR) and horizontal steam generators (VVER)

  11. Minimize corrosion degradation of steam generator tube materials

    International Nuclear Information System (INIS)

    Lu, Y.

    2006-01-01

    As part of a coordinated program, AECL is developing a set of tools to aid with the prediction and management of steam generator performance. Although stress corrosion cracking (of Alloy 800) has not been detected in any operating steam generator, for life management it is necessary to develop mechanistic models to predict the conditions under which stress corrosion cracking is plausible. Experimental data suggest that all steam generator tube materials are susceptible to corrosion degradation under some specific off-specification conditions. The tolerance to the chemistry upset for each steam generator tube alloy is different. Electrochemical corrosion behaviors of major steam generator tube alloys were studied under the plausible aggressive crevice chemistry conditions. The potential hazardous conditions leading to steam generator tube degradation and the conditions, which can minimize steam generator tube degradation have been determined. Recommended electrochemical corrosion potential/pH zones were defined for all major steam generator tube materials, including Alloys 600, 800, 690 and 400, under CANDU steam generator operating and startup conditions. Stress corrosion cracking tests and accelerated corrosion tests were carried out to verify and revise the recommended electrochemical corrosion potential/pH zones. Based on this information, utilities can prevent steam generator material degradation surprises by appropriate steam generator water chemistry management and increase the reliability of nuclear power generating stations. (author)

  12. Modeling of corrosion product migration in the secondary circuit of nuclear power plants with WWER-1200

    Science.gov (United States)

    Kritskii, V. G.; Berezina, I. G.; Gavrilov, A. V.; Motkova, E. A.; Zelenina, E. V.; Prokhorov, N. A.; Gorbatenko, S. P.; Tsitser, A. A.

    2016-04-01

    Models of corrosion and mass transfer of corrosion products in the pipes of the condensate-feeding and steam paths of the secondary circuit of NPPs with WWER-1200 are presented. The mass transfer and distribution of corrosion products over the currents of the working medium of the secondary circuit were calculated using the physicochemical model of mass transfer of corrosion products in which the secondary circuit is regarded as a cyclic system consisting of a number of interrelated elements. The circuit was divided into calculated regions in which the change in the parameters (flow rate, temperature, and pressure) was traced and the rates of corrosion and corrosion products entrainment, high-temperature pH, and iron concentration were calculated. The models were verified according to the results of chemical analyses at Kalinin NPP and iron corrosion product concentrations in the feed water at different NPPs depending on pH at 25°C (pH25) for service times τ ≥ 5000 h. The calculated pH values at a coolant temperature t (pH t ) in the secondary circuit of NPPs with WWER-1200 were presented. The calculation of the distribution of pH t and ethanolamine and ammonia concentrations over the condensate feed (CFC) and steam circuits is given. The models are designed for developing the calculation codes. The project solutions of ATOMPROEKT satisfy the safety and reliability requirements for power plants with WWER-1200. The calculated corrosion and corrosion product mass transfer parameters showed that the model allows the designer to choose between the increase of the correcting reagent concentration, the use of steel with higher chromium contents, and intermittent washing of the steam generator from sediments as the best solution for definite regions of the circuit.

  13. Cleanliness criteria to improve steam generator performance

    International Nuclear Information System (INIS)

    Schwarz, T.; Bouecke, R.; Odar, S.

    2005-01-01

    High steam generator performance is a prerequisite for high plant availability and possible life time extension. The major opponent to that is corrosion and fouling of the heating tubes. Such steam generator degradation problems arise from the continuous ingress of non-volatile contaminants, i.e. corrosion products and salt impurities may accumulate in the steam generators. These impurities have their origin in the secondary side systems. The corrosion products generally accumulate in the steam generators and form deposits not only in the flow restricted areas, such as on top of tube sheet and tube support structure, but also build scales on the steam generator heating tubes. In addition, the tube scales in general affect the steam generator thermal performance, which ultimately causes a reduction of power output. The most effective ways of counteracting all these degradation problems, and thus of improving the steam generator performance is to keep them in clean conditions or, if judged necessary, to plan cleaning measures such as mechanical tube sheet lancing or chemical cleaning. This paper presents a methodology how to assess the cleanliness condition of a steam generator by bringing together all available operational and inspection data such as thermal performance and water chemistry data. By means of this all-inclusive approach the cleanliness condition is quantified in terms of a fouling index. The fouling index allows to monitor the condition of a specific steam generator, compare it to other plants and, finally, to serve as criterion for cleaning measures such as chemical cleaning. The application of the cleanliness criteria and the achieved field results with respect to improvements of steam generator performance will be presented. (author)

  14. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 4C. Paks NPP: Analysis and testing. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-07-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material involves comparative analysis of the seismic analysis results of the reactor building for soft soil conditions, derivation of design response spectra for components and systems; and upper range design response spectra for soft soil site conditions at Paks NPP.

  15. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 4C. Paks NPP: Analysis and testing. Working material

    International Nuclear Information System (INIS)

    1996-01-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material involves comparative analysis of the seismic analysis results of the reactor building for soft soil conditions, derivation of design response spectra for components and systems; and upper range design response spectra for soft soil site conditions at Paks NPP

  16. Regulation of ageing steam generators

    International Nuclear Information System (INIS)

    Jarman, B.L.; Grant, I.M.; Garg, R.

    1998-01-01

    Recent years have seen leaks and shutdowns of Canadian CANDU plants due to steam generator tube degradation by mechanisms including stress corrosion cracking, fretting and pitting. Failure of a single steam generator tube, or even a few tubes, would not be a serious safety related event in a CANDU reactor. The leakage from a ruptured tube is within the makeup capacity of the primary heat transport system, so that as long as the operator takes the correct actions, the off-site consequences will be negligible. However, assurance that no tubes deteriorate to the point where their integrity could be seriously breached as result of potential accidents, and that any leakage caused by such an accident will be small enough to be inconsequential, can only be obtained through detailed monitoring and management of steam generator condition. This paper presents the AECB's current approach and future regulatory directions regarding ageing steam generators. (author)

  17. Corrosion Evaluation and Corrosion Control of Steam Generators

    International Nuclear Information System (INIS)

    Maeng, W. Y.; Kim, U. C.; Sung, K. W.; Na, J. W.; Lee, Y. H.; Lee, D. H.; Kim, K. M.

    2008-06-01

    Corrosion damage significantly influences the integrity and efficiency of steam generator. Corrosion problems of steam generator are unsolved issues until now even though much effort is made around world. Especially the stress corrosion cracking of heat exchange materials is the first issue to be solved. The corrosion protection method of steam generator is important and urgent for the guarantee of nuclear plant's integrity. The objectives of this study are 1) to evaluate the corrosion properties of steam generator materials, 2) to optimize the water chemistry of steam generator and 3) to develop the corrosion protection method of primary and secondary sides of steam generator. The results will be reflected to the water chemistry guideline for improving the integrity and efficiency of steam generator in domestic power plants

  18. Thermal performances of molten salt steam generator

    International Nuclear Information System (INIS)

    Yuan, Yibo; He, Canming; Lu, Jianfeng; Ding, Jing

    2016-01-01

    Highlights: • Thermal performances of molten salt steam generator were experimentally studied. • Overall heat transfer coefficient reached maximum with optimal molten salt flow rate. • Energy efficiency first rose and then decreased with salt flow rate and temperature. • Optimal molten salt flow rate and temperature existed for good thermal performance. • High inlet water temperature benefited steam generating rate and energy efficiency. - Abstract: Molten salt steam generator is the key technology for thermal energy conversion from high temperature molten salt to steam, and it is used in solar thermal power station and molten salt reactor. A shell and tube type molten salt steam generator was set up, and its thermal performance and heat transfer mechanism were studied. As a coupling heat transfer process, molten salt steam generation is mainly affected by molten salt convective heat transfer and boiling heat transfer, while its energy efficiency is also affected by the heat loss. As molten salt temperature increased, the energy efficiency first rose with the increase of heat flow absorbed by water/steam, and then slightly decreased for large heat loss as the absorbed heat flow still rising. At very high molten salt temperature, the absorbed heat flow decreased as boiling heat transfer coefficient dropping, and then the energy efficiency quickly dropped. As the inlet water temperature increased, the boiling region in the steam generator remarkably expanded, and then the steam generation rate and energy efficiency both rose with the overall heat transfer coefficient increasing. As the molten salt flow rate increased, the wall temperature rose and the boiling heat transfer coefficient first increased and then decreased according to the boiling curve, so the overall heat transfer coefficient first increased and then decreased, and then the steam generation rate and energy efficiency of steam generator both had maxima.

  19. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 1. Data related to sites and plants: Paks NPP, Kozloduy NPP. Working material

    International Nuclear Information System (INIS)

    1995-01-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains reports on data related to sites and NPPs Paks and Kozloduy

  20. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 1. Data related to sites and plants: Paks NPP, Kozloduy NPP. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains reports on data related to sites and NPPs Paks and Kozloduy.

  1. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 4D. Paks NPP: Analysis and testing. Working material

    International Nuclear Information System (INIS)

    1996-01-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains reports on seismic margin assessment and earthquake experience based methods for WWER-440/213 type NPPs; structural analysis and site inspection for site requalification; structural response of Paks NPP reactor building; analysis and testing of model worm type tanks on shaking table; vibration test of a worm tank model; evaluation of potential hazard for operating WWER control rods under seismic excitation

  2. Change in geometrical parameters of WWER high burnup fuel rods under operational conditions and transient testing

    International Nuclear Information System (INIS)

    Kanashov, B.; Amosov, S.; Lyadov, G.; Markov, D.; Ovchinnikov, V; Polenok, V.; Smirnov, A.; Sukhikh, A.; Bek, E.; Yenin, A.; Novikov, V.

    2001-01-01

    The paper discusses changes in fuel rods geometric parameters as result of operation conditions and burnups. The degree of geometry variability of fuel rods, cladding and column is one of the most important characteristics affecting fuel serviceability. On the other hand, changes in fuel rod geometric parameters influence fuel temperature, fission gas release, fuel-to-cladding stress strained state as well as the degree of interaction with FA skeleton elements and skeleton rigidity. Change in fuel-to-cladding gap is measured using compression technique. The axial distribution of fuel-to-cladding gap demonstrates the largest decrease of the gap in the region 500 to 2000 mm from the bottom of the fuel rod (WWER-440) and in the region of 500 to 3000 mm for WWER-1000. The cladding material creep in WWER fuel rods together with the radiation growth results in fuel rod cladding elongation. A set of transient tests for spent WWER-440 and WWER-1000 fuel rods carried out in SSC RIAR during a period 1995-1999, with the aim to estimate the changes in geometric parameters of FRs. The estimation of changes in outer diameter of cladding and fuel column and fuel-to-cladding gap are performed in transient conditions (changes in linear power range of 180 to 400 W/cm) for both WWER-440 and WWER-1000. WWER-440 fuel rods having the same burnup and close fuel-cladding contact before testing are subjected to considerable hoop cladding strain in testing up to 300 W/cm. But the hoop strain does not grow due to the structural changes in fuel column and decrease in central hole diameter occurred when the power is higher

  3. Testing installation for a steam generator

    International Nuclear Information System (INIS)

    Dubourg, M.

    1985-01-01

    The invention proposes a testing installation for a steam generator associated to a boiler, comprising a testing exchanger connected to a feeding circuit in secondary fluid and to a circuit to release the steam produced, and comprising a heating-tube bundle connected to a closed circuit of circulation of a primary coolant at the same temperature and at the pressure than the primary fluid. The heating-tube bundle of the testing exchanger has the same height than the primary bundle of the steam generator and the testing exchanger is at the same level and near the steam generator and is fed by the same secondary fluid such as it is subject to the same operation phases during a long period. The in - vention applies, more particularly, to the steam generators of pressurized water nuclear power plants [fr

  4. WWER-1000 reactor simulator. Material for training courses and workshops. 2. ed

    International Nuclear Information System (INIS)

    2005-01-01

    The International Atomic Energy Agency (IAEA) has established an activity in nuclear reactor simulation computer programs to assist its Member States in education. The objective is to provide, for a variety of advanced reactor types, insight and practice in their operational characteristics and their response to perturbations and accident situations. To achieve this, the IAEA arranges for the development and distribution of simulation programs and educational material and sponsors courses and workshops. The workshops are in two parts: techniques and tools for reactor simulator development; and the use of reactor simulators in education. Workshop material for the first part is covered in the IAEA publication: Training Course Series No.12, Reactor Simulator Development (2001). Course material for workshops using a pressurized water reactor (PWR) simulator developed for the IAEA by Cassiopeia Technologies Inc. of Canada is presented in the IAEA publication, Training Course Series No. 22, 2nd edition, Pressurized Water Reactor Simulator (2005) and Training Course Series No.23, 2nd edition, Boiling Water Reactor Simulator (2005). This report consists of course material for workshops using the WWER-1000 Reactor Department Simulator from the Moscow Engineering and Physics Institute, Russian Federation

  5. Experimental research on safety assurance of advanced WWER fuel cycles

    International Nuclear Information System (INIS)

    Krainov, Ju.; Kukushkin, Ju.

    2002-01-01

    The paper presents the results of experimental investigations on substantiation of implementation of a modernized butt joint for the WWER-440 reactor, carried out in the critical test facility 'P' in the RRC 'Kurchatov Institute'. The comparison results of the calculation and experimental data obtained in the physical startup of Volgodonsk NPP-1 with the WWER-1000 are also given. In the implementation of four-year fuel cycle in the WWER-440 with the average enrichment of fuel makeup 3.82% it was solved to conduct experimental research of power distribution in the vicinity of control rod butt junction. Moreover, it was assumed that adequate actions should be applied to eliminate inadmissible power jumps, if necessary. It is not available to measure their values in NPP conditions. Therefore, the power distribution near the butt joint was studied in a 19-rod bank installed in the critical test facility 'P' first for the normal design of the joint when surrounding fuel assemblies enrichment goes up. Then a set of calculation and tests was fulfilled to optimize a butt junction design. On the base of this research the composition of a butt junction was advanced by placing Hf plates into the junction. The effectiveness of modernized butt joint design was experimentally confirmed. In Volgodonsk NPP-1 with WWER-1000 the four-year fuel cycle is being implemented. During the physical startup of the reactor the measurements of the reactivity effects and coefficients were measured at the minimum controlled flux level, and the parameters of a number of critical states were recorded. The data obtained were compared with the calculation. The validity of the certified code package for forecasting the neutronic characteristics of WWER-1000 cores in the implementation of a four year fuel cycle has been supported (Authors)

  6. Corrosion Evaluation and Corrosion Control of Steam Generators

    Energy Technology Data Exchange (ETDEWEB)

    Maeng, W. Y.; Kim, U. C.; Sung, K. W.; Na, J. W.; Lee, Y. H.; Lee, D. H.; Kim, K. M

    2008-06-15

    Corrosion damage significantly influences the integrity and efficiency of steam generator. Corrosion problems of steam generator are unsolved issues until now even though much effort is made around world. Especially the stress corrosion cracking of heat exchange materials is the first issue to be solved. The corrosion protection method of steam generator is important and urgent for the guarantee of nuclear plant's integrity. The objectives of this study are 1) to evaluate the corrosion properties of steam generator materials, 2) to optimize the water chemistry of steam generator and 3) to develop the corrosion protection method of primary and secondary sides of steam generator. The results will be reflected to the water chemistry guideline for improving the integrity and efficiency of steam generator in domestic power plants.

  7. An expert system for steam generator maintenance

    International Nuclear Information System (INIS)

    Remond, A.

    1988-01-01

    The tube bundles in PWR steam generators are, by far, the major source of problems whether they are due to primary and secondary side corrosion mechanisms or to tube vibration-induced wear at tube support locations. Because of differences in SG operating, materials, and fabrication processes, the damage may differ from steam generator to steam generator. MPGV, an expert system for steam generator maintenance uses all steam generator data containing data on materials, fabrication processes, inservice inspection, and water chemistry. It has access to operational data for individual steam generators and contains models of possible degradation mechanisms. The objectives of the system are: · Diagnosing the most probable degradation mechanism or mechanisms by reviewing the entire steam generator history. · Identifying the tubes most exposed to future damage and evaluating the urgency of repair by simulating the probable development of the problem in time. · Establishing the appropriate preventive actions such as repair, inspection or other measures and establishing an action schedule. The system is intended for utilities either for individual plants before each inspection outage or any time an incident occurs or for a set of plants through a central MPGV center. (author)

  8. Studies and solutions of steam turbines for nuclear heating power stations

    International Nuclear Information System (INIS)

    Drahy, J.

    1979-01-01

    The possibilities of combined generation of heat and electric power and special features of the corresponding equipment for WWER type reactors are considered. Condensing steam turbines with bled steam points and the constructional solution of bled points are presented for heating the network water to 110 0 C, 120 0 C, and 160 0 C, respectively. The dimensions of the low pressure final stage of the turbine are given. Problems concerning condensing and bleeding turbines and combination types of back-pressure and condensing turbines as well as solutions to the design of 250 MW and 500 MW turbines are discussed

  9. Steam generators: critical components in nuclear steam supply systems

    Energy Technology Data Exchange (ETDEWEB)

    Stevens-Guille, P D

    1974-02-28

    Steam generators are critical components in power reactors. Even small internal leaks result in costly shutdowns for repair. Surveys show that leaks have affected one half of all water-cooled reactors in the world with steam generators. CANDU reactors have demonstrated the highest reliability. However, AECL is actively evolving new technology in design, manufacture, inspection and operation to maintain reliability. (auth)

  10. Moisture separator for steam generator level measurement system

    International Nuclear Information System (INIS)

    Cantineau, B.J.

    1987-01-01

    A steam generator level measurement system having a reference leg which is kept full of water by a condensation pot, has a liquid/steam separator in the connecting line between the condensation pot and the steam phase in the steam generator to remove excess liquid from the steam externally of the steam generator. This ensures that the connecting line does not become blocked. The separator pot has an expansion chamber which slows down the velocity of the steam/liquid mixture to aid in separation, and a baffle, to avoid liquid flow into the line connected to the condensate pot. Liquid separated is returned to the steam generator below the water level through a drain line. (author)

  11. Status and prospects of WWER in-core fuel management activities

    International Nuclear Information System (INIS)

    Novikov, A.N.; Pavlov, V.I.; Pavlovichev, A.M.; Proselkov, V.N.; Saprykin, V.V.

    1994-01-01

    A short review is given of recent extensive calculational and experimental studies carried out in Russia and Bulgaria for WWER fuel cycle modernization. The main activities performed at Kola NPP, Novovoronezh NPP, Kozloduy NPP and Balakovo NPP are outlined. Based on experience gained, the following improvements in the fuel cycle have been introduced: 1) increased fuel burnup; 2) reduced natural uranium consumption and decreased amount of separation work per energy output unit; 3) increased efficiency of the reactor emergency protection; 4) reduced fast neutron flux onto the reactor vessel. The main characteristics of modernized fuel cycles of WWER-440 and WWER-1000 are presented. 4 tabs., 3 figs., 14 refs

  12. Status and prospects of WWER in-core fuel management activities

    Energy Technology Data Exchange (ETDEWEB)

    Novikov, A N; Pavlov, V I; Pavlovichev, A M; Proselkov, V N; Saprykin, V V [Russian Research Centre Kurchatov Inst., Moscow (Russian Federation)

    1994-12-31

    A short review is given of recent extensive calculational and experimental studies carried out in Russia and Bulgaria for WWER fuel cycle modernization. The main activities performed at Kola NPP, Novovoronezh NPP, Kozloduy NPP and Balakovo NPP are outlined. Based on experience gained, the following improvements in the fuel cycle have been introduced: (1) increased fuel burnup; (2) reduced natural uranium consumption and decreased amount of separation work per energy output unit; (3) increased efficiency of the reactor emergency protection; (4) reduced fast neutron flux onto the reactor vessel. The main characteristics of modernized fuel cycles of WWER-440 and WWER-1000 are presented. 4 tabs., 3 figs., 14 refs.

  13. Characteristics of WWER-1000 fuel rod claddings and FA components from E635 alloy at burnups up to 72 MWd/kgU

    International Nuclear Information System (INIS)

    Nikulin, A.; Novikov, A.; Peregud, M.; Shishov, V.; Shevyakov, A.; Volkova, I.; Novoselov, A.; Kobylyansky, G.

    2011-01-01

    In this paper operation experience, results of investigated E365 alloy components of Balakovo NPP Unit 1 and Kalinin NPP unit 1 fuel assemblies are presented. Appearance, shape changes and geometric size, corrosion state of guide thimbles, angles and fuel rods, corrosion of fuel claddings are studied. At the end authors concluded that: I) E635 alloy corroborated its high operation reliability as fuel claddings and WWER-1000 FA components during 6 year service to the fuel burnup of 72MWd/kgU; II) Based on the results from the post-irradiation investigations of the fuel rods and other structural elements of WWER-1000 FAA, fabricated from E635 alloy, in terms of the basic operational characteristics, their resources after the 6 year operation cycle have not been exhausted; III) The geometrical parameters, corrosion states, tensile properties of items fabricated from fuel alloy did not attain the values that would prevent their further operation: 1) the elongations of the fuel rods at the mean burnups up to 66.2 MWd/kgU do not exceed 15 mm or 4.9%; 8) the amount of the oxide coat at surface of GT and CT does not exceed 45 μm, the hydrogen content is <0.03% mass; 9) the oxide coat at the surfaces of the frame angles does not exceed 50 μm, the hydrogen content is <0.04% mass

  14. Surveillance specimen programmes for WWER reactor vessels in the Czech Republic

    International Nuclear Information System (INIS)

    Brynda, J.; Hogel, J.; Brumovsky, M.

    2003-01-01

    The present state of materials degradation in WWER reactor pressure vessels manufactured in the Czech Republic is highlighted. The standard surveillance program for WWER-440/V-213 type reactors is described and its deficiencies together with the main results obtained are discussed. A new supplementary surveillance program meeting all requirements for PWR type reactors has been developed and launched. An entirely new design was chosen for the surveillance programme for WWER-1000/V-320 type reactor pressure vessels. Materials selection, container design and location as well as the withdrawal plan connected with ex-vessel fluence monitoring are described

  15. Thermal-hydraulics in recirculating steam generators

    International Nuclear Information System (INIS)

    Carver, M.B.; Carlucci, L.N.; Inch, W.W.R.

    1981-04-01

    This manual describes the THIRST code and its use in computing three-dimensional two-phase flow and heat transfer in a steam generator under steady state operation. The manual is intended primarily to facilitate the application of the code to the analysis of steam generators typical of CANDU nuclear stations. Application to other steam generator designs is also discussed. Details of the assumptions used to formulate the model and to implement the numerical solution are also included

  16. Steam generator life cycle management: Ontario Power Generation (OPG) experience

    International Nuclear Information System (INIS)

    Maruska, C.C.

    2002-01-01

    A systematic managed process for steam generators has been implemented at Ontario Power Generation (OPG) nuclear stations for the past several years. One of the key requirements of this managed process is to have in place long range Steam Generator Life Cycle Management (SG LCM) plans for each unit. The primary goal of these plans is to maximize the value of the nuclear facility through safe and reliable steam generator operation over the expected life of the units. The SG LCM plans integrate and schedule all steam generator actions such as inspection, operation, maintenance, modifications, repairs, assessments, R and D, performance monitoring and feedback. This paper discusses OPG steam generator life cycle management experience to date, including successes, failures and how lessons learned have been re-applied. The discussion includes relevant examples from each of the operating stations: Pickering B and Darlington. It also includes some of the experience and lessons learned from the activities carried out to refurbish the steam generators at Pickering A after several years in long term lay-up. The paper is structured along the various degradation modes that have been observed to date at these sites, including monitoring and mitigating actions taken and future plans. (author)

  17. Non-polluting steam generators with fluidized-bed furnaces

    Energy Technology Data Exchange (ETDEWEB)

    Brandes, H [Deutsche Babcock A.G., Oberhausen (Germany, F.R.)

    1979-07-01

    The author reports on a 35 MW steam generator with hard coal fluidized-bed furnace a planned 35 MW steam generator with flotation-dirt fluidized-bed furnace, and on planned steam generators for fluidized-bed firing of hard coal up to a steam power of about 200 MW.

  18. CAREM-25 Steam Generator Stability Analysis

    International Nuclear Information System (INIS)

    Rabiti, A.; Delmastro, D.

    2003-01-01

    In this work the stability of a once-through CAREM-25 steam generator is analyzed.A fix nodes numerical model, that allows the modelling of the liquid, two-phase and superheated steam zones, is implemented.This model was checked against a mobile finite elements model under saturated steam conditions at the channel exit and a good agreement was obtained.Finally the stability of a CAREM steam generator is studied and the range of in let restrictions that a assure the system stability is analyzed

  19. Steam generators

    International Nuclear Information System (INIS)

    Hayden, R.L.J.

    1979-01-01

    Steam generators for nuclear reactors are designed so that deposition of solids on the surface of the inlet side of the tubesheet or the inlet header with the consequent danger of corrosion and eventual tube failure is obviated or substantially reduced. (U.K.)

  20. Failure analysis of retired steam generator tubings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Pyo; Kim, J. S.; Hwang, S. S. and others

    2005-04-15

    Degradation of steam generator leads to forced outage and extension of outage, which causes increase in repair cost, cost of purchasing replacement power and radiation exposure of workers. Steam generator tube rupture incident occurred in Uljin 4 in 2002, which made public sensitive to nuclear power plant. To keep nuclear energy as a main energy source, integrity of steam generator should be demonstrated. Quantitative relationship between ECT(eddy current test) signal and crack size is needed in assesment of integrity of steam generator in pressurized water reactor. However, it is not fully established for application in industry. Retired steam generator of Kori 1 has many kinds of crack such as circumferential and axial primary water stress corrosion crack and outer diameter stress corrosion crack(ODSCC). So, it can be used in qualifying and improving ECT technology and in condition monitoring assesment for crack detected in ISI(in service inspection). In addition, examination of pulled tube of Kori 1 retired steam generator will give information about effectiveness of non welded sleeving technology which was employed to repair defect tubes and remedial action which was applied to mitigate ODSCC. In this project, hardware such as semi hot lab. for pulled tube examination and modification transportation cask for pulled tube and software such as procedure of transportation of radioactive steam generator tube and non-destructive and destructive examination of pulled tube were established. Non-destructive and destructive examination of pulled tubes from Kori 1 retired steam generator were performed in semi hot lab. Remedial actions applied to Kori 1 retired steam generator, PWSCC trend and bulk water chemistry and crevice chemistry in Kori 1 were evaluated. Electrochemical decontamination technology for pulled tube was developed to reduce radiation exposure and enhance effectiveness of pulled tube examination. Multiparameter algorithm developed at ANL, USA was

  1. Darlington steam generator life assurance program

    International Nuclear Information System (INIS)

    Jelinski, E.; Dymarski, M.; Maruska, C.; Cartar, E.

    1995-01-01

    The Darlington Nuclear Generating Station belonging to Ontario Hydro is one of the most modern and advanced nuclear generating stations in the world. Four reactor units each generate 881 net MW, enough to provide power to a major city, and representing approximately 20% of the Ontario grid. The nuclear generating capacity in Ontario represents approximately 60% of the grid. In order to look after this major asset, many proactive preventative and predictive maintenance programs are being put in place. The steam generators are a major component in any power plant. World wide experience shows that nuclear steam generators require specialized attention to ensure reliable operation over the station life. This paper describes the Darlington steam generator life assurance program in terms of degradation identification, monitoring and management. The requirements for chemistry control, surveillance of process parameters, surveillance of inspection parameters, and the integration of preventative and predictive maintenance programs such as water lancing, chemical cleaning, RIHT monitoring, and other diagnostics to enhance our understanding of life management issues are identified and discussed. We conclude that we have advanced proactive activities to avoid and to minimize many of the problems affecting other steam generators. An effective steam generator maintenance program must expand the knowledge horizon to understand life limiting processes and to analyze and synthesize observations with theory. (author)

  2. Materials choices for the advanced LWR steam generators

    International Nuclear Information System (INIS)

    Paine, J.P.N.; Shoemaker, C.E.; McIlree, A.R.

    1987-01-01

    Current light water reactor (LWR) steam generators have been affected by a variety of corrosion and mechanical damage degradation mechanisms. Included are wear caused by tube vibration, intergranular corrosion, pitting, and thinning or wastage of the steam generator tubing and accelerated corrosion of carbon steel supports (denting). The Electric Power Research Institute (EPRI) and the Steam Generator Owners Groups (I, II) have sponsored laboratory and field studies to provide ameliorative actions for the majority of the damage forms experienced to date. Some of the current corrosion mechanisms are aggravated or caused by unique materials choices or materials interactions. New materials have been proposed and at least partially qualified for use in replacement model steam generators, including an advanced LWR design. In so far as possible, the materials choices for the advanced LWR steam generator avoid the corrosion pitfalls seemingly inherent in the current designs. The EPRI Steam Generator Project staff has recommended materials and design choices for a new steam generator. Based on these recommendations we believe that the advanced LWR steam generators will be much less affected by corrosion and mechanical damage mechanisms than are now experienced

  3. Study on reverse flow characteristics under natural circulation in inverted U-tube steam generator

    International Nuclear Information System (INIS)

    Duan Jun; Zhou Tao; Zhang Lei; Hong Dexun; Liu Ping

    2013-01-01

    Natural circulation is important for application in the nuclear power industry. Aiming at the steam generator of AP1000 pressurized water reactor loop, the mathematical model was established to analysis the reverse flow of single-phase water in the inverted U-tubes of a steam generator in a natural circulation system. The length distribution and the mass flow rates in both tubes with normal and reverse flow were determined respectively. The research results show that the reverse flow may result in sharp decrease of gravity pressure head, circulation mass flow rate and heat release rate of natural circulation. It has adverse influence on natural circulation. (authors)

  4. Development of requirements for seismic upgrading of equipment of existing WWER-440 and WWER-1000 type NPPs

    International Nuclear Information System (INIS)

    Kaznovsky, S.; Ostretsov, I.

    1993-01-01

    The change in seismology data and safety demands a necessity arose for seismic upgrading of the existing operating NPPs of WWER type which have been originally designed and built without or with simplifies calculations of seismic influences. The paper describes the traditional methods and approaches and calculation-experimental method for examining and ensuring of equipment seismic resistance at the NPPs directly. Method of ground explosions is included as well

  5. Steam generator operating experience update, 1982-1983

    International Nuclear Information System (INIS)

    Frank, L.

    1984-06-01

    This report is a continuation of earlier reports by the staff addressing pressurized water reactor steam generator operating experience. NUREG-0886, Steam Generator Tube Experience, published in February 1982 summarized experience in domestic and foreign plants through December 1981. This report summarizes steam generator operating experience in domestic plants for the years 1982 and 1983. Included are new problems encountered with secondary-side loose parts, sulfur-induced stress-assisted corrosion cracking, and flow-induced vibrational wear in the new preheater design steam generators. The status of Unresolved Safety Issues A3, A4, and A5 is also discussed

  6. Strategic maintenance plan for Cernavoda steam generators

    International Nuclear Information System (INIS)

    Cicerone, T.; Dhar, D.; VandenBerg, J.P.

    2002-01-01

    Steam generators are among the most important pieces of equipment in a nuclear power plant. They are required full time during the plant operation and obviously no redundancy exists. Past experience has shown that those utilities which implemented comprehensive steam generator inspection and maintenance programs and strict water chemistry controls, have had good steam generator performance that supports good overall plant performance. The purpose of this paper is to discuss a strategic Life Management and Operational-monitoring program for the Cernavoda steam generators. The program is first of all to develop a base of expertise for the management of the steam generator condition; and that is to be supported by a program of actions to be accomplished over time to assess their condition, to take measures to avoid degradation and to provide for inspections, cleaning and modifications as necessary. (author)

  7. Comparison of HRA methods based on WWER-1000 NPP real and simulated accident scenarios

    International Nuclear Information System (INIS)

    Petkov, Gueorgui

    2010-01-01

    Full text: Adequate treatment of human interactions in probabilistic safety analysis (PSA) studies is a key to the understanding of accident sequences and their relative importance in overall risk. Human interactions with machines have long been recognized as important contributors to the safe operation of nuclear power plants (NPP). Human interactions affect the ordering of dominant accident sequences and hence have a significant effect on the risk of NPP. By virtue of the ability to combine the treatment of both human and hardware reliability in real accidents, NPP fullscope, multifunctional and computer-based simulators provide a unique way of developing an understanding of the importance of specific human actions for overall plant safety. Context dependent human reliability assessment (HRA) models, such as the holistic decision tree (HDT) and performance evaluation of teamwork (PET) methods, are the so-called second generation HRA techniques. The HDT model has been used for a number of PSA studies. The PET method reflects promising prospects for dealing with dynamic aspects of human performance. The paper presents a comparison of the two HRA techniques for calculation of post-accident human error probability in the PSA. The real and simulated event training scenario 'turbine's stop after loss of feedwater' based on standard PSA model assumptions is designed for WWER-1000 computer simulator and their detailed boundary conditions are described and analyzed. The error probability of post-accident individual actions will be calculated by means of each investigated technique based on student's computer simulator training archives

  8. Vertical steam generator

    International Nuclear Information System (INIS)

    Cuda, F.; Kondr, M.; Kresta, M.; Kusak, V.; Manek, O.; Turon, S.

    1982-01-01

    A vertical steam generator for nuclear power plants and dual purpose power plants consists of a cylindrical vessel in which are placed heating tubes in the form upside-down U. The heating tubes lead to the jacket of the cylindrical collector placed in the lower part of the steam generator perpendicularly to its vertical axis. The cylindrical collector is divided by a longitudinal partition into the inlet and outlet primary water sections of the heating tubes. One ends of the heating tube leads to the jacket of the collector for primary water feeding and the second ends of the heating tubes into the jacket of the collector which feeds and offtakes primary water from the heating tubes. (B.S.)

  9. Digital simulation for nuclear once-through steam generators

    International Nuclear Information System (INIS)

    Chen, A.T.

    1976-01-01

    Mathematical models for calculating the dynamic response of the Oconee type once through steam generator (OTSG) and the integral economizer once through steam generator (IEOTSG) was developed and presented in this dissertation. Linear and nonlinear models of both steam generator types were formulated using the state variable, lumped parameter approach. Transient and frequency responses of system parameters were calculated for various perturbations from both the primary coolant side and the secondary side. Transients of key parameters, including primary outlet temperature, superheated steam outlet temperature, boiling length/subcooled length and steam pressure, were generated, compared and discussed for both steam generator types. Frequency responses of delta P/sub s//deltaT/sub pin/ of the linear OTSG model were validated by using the dynamic testing results obtained at the Oconee I nuclear power station. A sensitivity analysis in both the time and the frequency domains was performed. It was concluded that the mathematical and computer models developed in this dissertation for both the OTSG and the IEOTSG are suitable for overall plant performance evaluation and steam generator related component/system design analysis for nuclear plants using either type of steam generator

  10. Steam Generator Tube Integrity Program: Surry Steam Generator Project, Hanford site, Richland, Benton County, Washington: Environmental assessment

    International Nuclear Information System (INIS)

    1980-03-01

    The US Nuclear Regulatory Commission (NRC) has placed a Nuclear Regulatory Research Order with the Richland Operations Office of the US Department of Energy (DOE) for expanded investigations at the DOE Pacific Northwest Laboratory (PNL) related to defective pressurized water reactor (PWR) steam generator tubing. This program, the Steam Generator Tube Integrity (SGTI) program, is sponsored by the Metallurgy and Materials Research Branch of the NRC Division of Reactor Safety Research. This research and testing program includes an additional task requiring extensive investigation of a degraded, out-of-service steam generator from a commercial nuclear power plant. This comprehensive testing program on an out-of-service generator will provide NRC with timely and valuable information related to pressurized water reactor primary system integrity and degradation with time. This report presents the environmental assessment of the removal, transport, and testing of the steam generator along with decontamination/decommissioning plans

  11. The casebook of technical presentation on a steam generator

    International Nuclear Information System (INIS)

    1986-05-01

    This casebook consists of seven presentations, which are measures and experience of maintenance of water quality in PWR generator, corrosion in steam generator, safely evaluation by management and closing in steam generator, testing of eddy current in steam generator, unsettled problems of safety in steam generator and maintenance of water quality in PWR generator.

  12. Optimization of design solutions on safety and economy for power unit of NPP with WWER reactor of new generation. Annex 8

    International Nuclear Information System (INIS)

    Krushelnitsky, V.N.; Berkovich, V.M.; Shvyrayev, Yu.; Podshebaykin, A.K.; Fil, N.S.

    2002-01-01

    Development of new generation WWER reactors is being carried out in Russia. These new projects with WWER reactors aim to achieve increased levels of safety and reduced costs. This paper describes these designs and discusses the main factors leading to the safety level increase and the improved economics. (author)

  13. Comparison of technical and economical factors of 1000-MW steam turbines at 3000 and 1500 r.p.m. for nuclear power plants

    International Nuclear Information System (INIS)

    Markov, N.M.; Safonov, L.P.

    1980-01-01

    The problem of unification of the low-pressure cilinders (LPC) for turbo-generator units of nuclear power plants with power of 1000 MW on base of the WWER and RBMK type reactors is discussed. The results of the comparison of the K-1000-60/1500 and K-1000-60/3000 turbines in the thermal efficiency of flow passages and arrangements masses and dimensions, static and dynamic strength manoeurrability and reliability are given. To cerry out the correct comparison methods adoped as branch standards thermal calculations, calculation of low-potential part and thermal arrangements, calculations of temperature fields and of low cycle fatigue calculation of the erosion failure accumulation of blades calculation of the blades for the last steps have been used. A conclusion is made that in the nearest future it is necessary to produce the K-1000-60/1500 and K-1000-60/3000 turbines simultaneously. The low-speed lurbines with three LPC are preferable for the nuclear power plants with average annual temperatures of water up to 20 deg C and the high-speed turbines and the K-1000-60/1500 units with two LPC are expedient for nuclear power plants with temperatures higher than 20 deg C. Introduction of the turboplants with reduced number of LPC in the nuclear power engineering provides the increase of reliability, maintenance fitness and the decrease of building costs and transport expenses

  14. Model of reverse steam generator

    International Nuclear Information System (INIS)

    Malasek, V.; Manek, O.; Masek, V.; Riman, J.

    1987-01-01

    The claim of Czechoslovak discovery no. 239272 is a model designed for the verification of the properties of a reverse steam generator during the penetration of water, steam-water mixture or steam into liquid metal flowing inside the heat exchange tubes. The design may primarily be used for steam generators with a built-in inter-tube structure. The model is provided with several injection devices configured in different heat exchange tubes, spaced at different distances along the model axis. The design consists in that between the pressure and the circumferential casings there are transverse partitions and that in one chamber consisting of the circumferential casings, pressure casing and two adjoining partitions there is only one passage of the injection device through the inter-tube space. (Z.M.). 1 fig

  15. Predicting steam generator crevice chemistry

    International Nuclear Information System (INIS)

    Burton, G.; Strati, G.

    2006-01-01

    'Full text:' Corrosion of steam cycle components produces insoluble material, mostly iron oxides, that are transported to the steam generator (SG) via the feedwater and deposited on internal surfaces such as the tubes, tube support plates and the tubesheet. The build up of these corrosion products over time can lead to regions of restricted flow with water chemistry that may be significantly different, and potentially more corrosive to SG tube material, than the bulk steam generator water chemistry. The aim of the present work is to predict SG crevice chemistry using experimentation and modelling as part of AECL's overall strategy for steam generator life management. Hideout-return experiments are performed under CANDU steam generator conditions to assess the accumulation of impurities in hideout, and return from, model crevices. The results are used to validate the ChemSolv model that predicts steam generator crevice impurity concentrations, and high temperature pH, based on process parameters (e.g., heat flux, primary side temperature) and blowdown water chemistry. The model has been incorporated into ChemAND, AECL's system health monitoring software for chemistry monitoring, analysis and diagnostics that has been installed at two domestic and one international CANDU station. ChemAND provides the station chemists with the only method to predict SG crevice chemistry. In one recent application, the software has been used to evaluate the crevice chemistry based on the elevated, but balanced, SG bulk water impurity concentrations present during reactor startup, in order to reduce hold times. The present paper will describe recent hideout-return experiments that are used for the validation of the ChemSolv model, station experience using the software, and improvements to predict the crevice electrochemical potential that will permit station staff to ensure that the SG tubes are in the 'safe operating zone' predicted by Lu (AECL). (author)

  16. Development of a steam generator lancing system

    International Nuclear Information System (INIS)

    Jeong, Woo-Tae; Kim, Seok-Tae; Hong, Sung-Yull

    2006-01-01

    It is recommended to clean steam generators of nuclear power plants during plant outages. Under normal operations, sludge is created and constantly accumulates in the steam generators. The constituents of this sludge are different depending on each power plant characteristics. The sludge of the Kori Unit 1 steam generator, for example, was found to be composed of 93% ferrous oxide, 3% carbon and 1% of silica oxide and nickel oxide each. The research to develop a lancing system that would remove sludge deposits from the tubesheet of a steam generator was started in 1998 by the Korea Electric Power Research Institute (KEPRI) of the Korea Electric Power Corporation (KEPCO). The first commercial domestic lancing system in Korea, and KALANS-I Lancing System, was completed in 2000 for Kori Unit 1 for cleaning the tubesheet of its Westinghouse Delta-60 steam generator. Thereafter, the success of the development and site implementation of the KALANS-I lancing system for YGN Units 1 and 2 and Ulchin Units 3 and 4 was also realized in 2004 for sludge removal at those sites. The upper bundle cleaning system for Westinghouse model F steam generators is now under development

  17. Method to detect steam generator tube leakage

    International Nuclear Information System (INIS)

    Watabe, Kiyomi

    1994-01-01

    It is important for plant operation to detect minor leakages from the steam generator tube at an early stage, thus, leakage detection has been performed using a condenser air ejector gas monitor and a steam generator blow down monitor, etc. In this study highly-sensitive main steam line monitors have been developed in order to identify leakages in the steam generator more quickly and accurately. The performance of the monitors was verified and the demonstration test at the actual plant was conducted for their intended application to the plants. (author)

  18. Future aspects for liquid metal heated steam generators

    International Nuclear Information System (INIS)

    Jansing, W.; Ratzel, W.; Vinzens, K.

    1975-01-01

    The present status of steam generators is shown. The experience gained until now is expressed in form of basic points. The most important design criteria for steam generator systems are outlined. On the basis of these design criteria, two possible steam generator concepts are shown. Costs in relationship to the repair concepts of two modular steam generators (thermal output 156 and 625 MW) and a pool design of 625 MW are compared. (author)

  19. Future aspects for liquid metal heated steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Jansing, W; Ratzel, W; Vinzens, K

    1975-07-01

    The present status of steam generators is shown. The experience gained until now is expressed in form of basic points. The most important design criteria for steam generator systems are outlined. On the basis of these design criteria, two possible steam generator concepts are shown. Costs in relationship to the repair concepts of two modular steam generators (thermal output 156 and 625 MW) and a pool design of 625 MW are compared. (author)

  20. Two-phase flow field simulation of horizontal steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Rabiee, Ataollah; Kamalinia, Amir Hossein; Hadad, Kamal [School of Mechanical Engineering, Shiraz University, Shiraz (Iran, Islamic Republic of)

    2017-02-15

    The analysis of steam generators as an interface between primary and secondary circuits in light water nuclear power plants is crucial in terms of safety and design issues. VVER-1000 nuclear power plants use horizontal steam generators which demand a detailed thermal hydraulics investigation in order to predict their behavior during normal and transient operational conditions. Two phase flow field simulation on adjacent tube bundles is important in obtaining logical numerical results. However, the complexity of the tube bundles, due to geometry and arrangement, makes it complicated. Employment of porous media is suggested to simplify numerical modeling. This study presents the use of porous media to simulate the tube bundles within a general-purpose computational fluid dynamics code. Solved governing equations are generalized phase continuity, momentum, and energy equations. Boundary conditions, as one of the main challenges in this numerical analysis, are optimized. The model has been verified and tuned by simple two-dimensional geometry. It is shown that the obtained vapor volume fraction near the cold and hot collectors predict the experimental results more accurately than in previous studies.

  1. Comments on US LMFBR steam generator base technology

    International Nuclear Information System (INIS)

    Simmons, W.R.

    1984-01-01

    The development of steam generators for the LMFBR was recognized from the onset by the AEC, now DOE, as a difficult, challenging, and high-priority task. The highly reactive nature of sodium with water/steam requires that the sodium-water/steam boundaries of LMFBR steam generators possess a degree of leak-tightness reliability not normally attempted on a commercial scale. In addition, the LMFBR steam generator is subjected to high fluid temperatures and severe thermal transients. These requirements place great demand on materials, fabrication processes, and inspection methods; and even greater demands on the designer to provide steam generators that can meet these demanding requirements, be fabricated without unreasonable shop requirements, and tolerate off-normal effects

  2. Steam Generator Inspection Planning Expert System

    International Nuclear Information System (INIS)

    Rzasa, P.

    1987-01-01

    Applying Artificial Intelligence technology to steam generator non-destructive examination (NDE) can help identify high risk locations in steam generators and can aid in preparing technical specification compliant eddy current test (ECT) programs. A steam Generator Inspection Planning Expert System has been developed which can assist NDE or utility personnel in planning ECT programs. This system represents and processes its information using an object oriented declarative knowledge base, heuristic rules, and symbolic information processing, three artificial intelligence based techniques incorporated in the design. The output of the system is an automated generation of ECT programs. Used in an outage inspection, this system significantly reduced planning time

  3. Thermal-hydraulic analysis of total loss of steam generator feed water in WWER-440

    International Nuclear Information System (INIS)

    Sabotinov, L.; Cadet-Mercier, S.

    2001-01-01

    The analysis is carried out for a WWER-440/V270 with upgraded primary safety valves (replacement of the existing PRZ safety valves with Pilot Operated Relief Valves (PORV) of the type SEBIM (France)) The current analysis is focused on the scenario 'Total Loss of SGs Feed Water' with application of the operator action of primary system 'Feed and Bleed' in order to check the effectiveness of the installed pressurizer SEBIM valves and to verify that the operator can cool down the reactor system and cope with this accident. The calculations have been performed at the Institute of Protection and Nuclear Safety (IPSN) in Fontenay-aux-Roses with the computer code CATHARE 2 Version 1.3L1. CATHARE is a French best estimate thermal-hydraulic program for accident analysis in the light water nuclear reactors, developed with the participation of the IPSN (Institut de Protection et Surete Nucleaire), CEA (Commissariat a l'Energie Atomique), Framatome and EdF (Electricite de France). (author)

  4. Approaches for accounting and prediction of fast neutron fluence on WWER pressure vessels and results of validation of calculational procedure

    International Nuclear Information System (INIS)

    Borodkin, P.G.; Khrennikov, N.N.; Ryabinin, Yu.A.; Adeev, V.A.

    2015-01-01

    A description is given of the universal procedure for calculation of fast neutron fluence (FNF) on WWER vessels. Approbation of the calculation procedure was carried out by comparing the calculation results for this procedure and measurements on the outer surface of the WWER-440 and WWER-1000 vessels. In addition, an estimation of the uncertainty of the settlement procedure was made in accordance with the requirements of regulatory documents. The developed procedure is applied at Kola NPP for independent fast neutron fluence estimates on the WWER-440 reactor vessels when planning core loads taking into account the introduction of new fuels. The results of the pilot operation of the procedure for calculating FNF at the Kola NPP were taken into account when improving the procedure and its application to the calculations of FNF on the WWER-1000 vessels [ru

  5. Relap5/Mod2.5 analyses of SG primary collector head rupture in WWER-440 reactor

    International Nuclear Information System (INIS)

    Szczurek, J.

    1995-01-01

    The paper presents the results of the analyses of steam generator (SG) manifold cover rupture performed with RELAP5/MOD2.5 (version provided by RMA, Albuquerque, for PC PPS). The calculations presented are based on RELAP5 input deck for WWER-440/213 Bobunice NPP, developed within the framework of IAEA TC Project RER/9/004. The presented analyses are directed toward determining the maximum amount of reactor coolant discharged into the secondary coolant system and the maximum amount of contaminated coolant release to the atmosphere. In all cases considered in the analysis, maximum ECCS injection capacity is assumed. The paper includes only the cases without any operator actions within the time period covered by the analyses. In particular, the primary loop isolation valves are not used for isolating the broken steam generator. Two scenarios are analysed: with and without the SG safety valve stuck open

  6. Relap5/Mod2.5 analyses of SG primary collector head rupture in WWER-440 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Szczurek, J. [Inst. of Atomic Energy, Swierk (Poland)

    1995-12-31

    The paper presents the results of the analyses of steam generator (SG) manifold cover rupture performed with RELAP5/MOD2.5 (version provided by RMA, Albuquerque, for PC PPS). The calculations presented are based on RELAP5 input deck for WWER-440/213 Bobunice NPP, developed within the framework of IAEA TC Project RER/9/004. The presented analyses are directed toward determining the maximum amount of reactor coolant discharged into the secondary coolant system and the maximum amount of contaminated coolant release to the atmosphere. In all cases considered in the analysis, maximum ECCS injection capacity is assumed. The paper includes only the cases without any operator actions within the time period covered by the analyses. In particular, the primary loop isolation valves are not used for isolating the broken steam generator. Two scenarios are analysed: with and without the SG safety valve stuck open. 3 refs.

  7. Relap5/Mod2.5 analyses of SG primary collector head rupture in WWER-440 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Szczurek, J [Inst. of Atomic Energy, Swierk (Poland)

    1996-12-31

    The paper presents the results of the analyses of steam generator (SG) manifold cover rupture performed with RELAP5/MOD2.5 (version provided by RMA, Albuquerque, for PC PPS). The calculations presented are based on RELAP5 input deck for WWER-440/213 Bobunice NPP, developed within the framework of IAEA TC Project RER/9/004. The presented analyses are directed toward determining the maximum amount of reactor coolant discharged into the secondary coolant system and the maximum amount of contaminated coolant release to the atmosphere. In all cases considered in the analysis, maximum ECCS injection capacity is assumed. The paper includes only the cases without any operator actions within the time period covered by the analyses. In particular, the primary loop isolation valves are not used for isolating the broken steam generator. Two scenarios are analysed: with and without the SG safety valve stuck open. 3 refs.

  8. Operating experiences with 1 MW steam generator

    Energy Technology Data Exchange (ETDEWEB)

    Sano, A; Kanamori, A; Tsuchiya, T

    1975-07-01

    1 MW steam generator, which was planned as the first stage of steam generator development in Power Reactor and Nuclear Fuel Corp. (PNC) in Japan, is a single-unit, once-through, integrated shell and tube type with multi-helical coil tubes. It was completed in Oarai Engineering Center of PNC in March of 1971, and the various performance tests were carried out up to April, 1972. After the dismantle of the steam generator for structural inspection and material test, it was restored with some improvements. In this second 1 MW steam generator, small leak occurred twice during normal operation. After repairing the failure, the same kind of performance tests as the first steam generator were conducted in order to verify the thermal insulation effect of argon gas in downcomer zone from March to June, 1974. In this paper the above operating experiences were presented including the outline of some performance test results. (author)

  9. Maintenance and repair of LMFBR steam generators

    International Nuclear Information System (INIS)

    Verriere, P.; Alanche, J.; Minguet, J.L.

    1984-06-01

    After some general remarks on the French fast neutron system, this paper presents the state of the program for the construction of fast reactor in France. Then, the general design of Super Phenix 1 steam generator components is outlined and, the in-service monitoring systems and protective devices with which they are equiped are briefly described. The methods used, in the event of leakage, for leak location, steam generator inspection, steam generator repair and putting the affected loop back into service, are discussed. There are two main lines of research, relating respectively to the means of water leak detection in sodium and the inspection arrangements that will be used either periodically, or following a sodium-water reaction. Finally, after a brief description of the steam generator, this paper describes the four incidents (leaks) that occurred on the Phenix steam generator in the course of 1982 and 1983, and the subsequent repair operations

  10. The relevance of the IFPE Database to the modelling of WWER-type fuel behaviour

    International Nuclear Information System (INIS)

    Killeen, J.; Sartori, E.

    2006-01-01

    The aim of the International Fuel Performance Experimental Database (IFPE Database) is to provide, in the public domain, a comprehensive and well-qualified database on zircaloy-clad UO 2 fuel for model development and code validation. The data encompass both normal and off-normal operation and include prototypic commercial irradiations as well as experiments performed in Material Testing Reactors. To date, the Database contains over 800 individual cases, providing data on fuel centreline temperatures, dimensional changes and FGR either from in-pile pressure measurements or PIE techniques, including puncturing, Electron Probe Micro Analysis (EPMA) and X-ray Fluorescence (XRF) measurements. This work in assembling and disseminating the Database is carried out in close co-operation and co-ordination between OECD/NEA and the IAEA. The majority of data sets are dedicated to fuel behaviour under LWR irradiation, and every effort has been made to obtain data representative of BWR, PWR and WWER conditions. In each case, the data set contains information on the pre-characterisation of the fuel, cladding and fuel rod geometry, the irradiation history presented in as much detail as the source documents allow, and finally any in-pile or PIE measurements that were made. The purpose of this paper is to highlight data that are relevant specifically to WWER application. To this end, the NEA and IAEA have been successful in obtaining appropriate data for both WWER-440 and WWER-1000-type reactors. These are: 1) Twelve (12) rods from the Finnish-Russian co-operative SOFIT programme; 2) Kola-3 WWER-440 irradiation; 3) MIR ramp tests on Kola-3 rods; 4) Zaporozskaya WWER-1000 irradiation; 5) Novovoronezh WWER-1000 irradiation. Before reviewing these data sets and their usefulness, the paper touches briefly on recent, more novel additions to the Database and on progress made in the use of the Database for the current IAEA FUMEX II Project. Finally, the paper describes the Computer

  11. US PWR steam generator management: An overview

    International Nuclear Information System (INIS)

    Welty, C.S. Jr.

    1997-01-01

    This paper provides an overview on the status of steam generator management activities in US PWRs, and includes: (1) an overview of the impact of steam generator problems; (2) a brief discussion of historical damage trends and the current damage mechanism of most concern; (3) a discussion of the elements of open-quotes steam generator managementclose quotes; and (4) a description of the approach being followed to implement a degradation-specific protocol for tubing inspection and repair. This paper was prepared in conjunction with another paper presented during the Plenary Session of this Conference, open-quotes Steam Generator Degradation: Current Mitigation Strategies for Controlling Corrosionclose quotes, and is provided as a supplement to that material

  12. Report on US-Japan 1983 meetings on steam generators

    International Nuclear Information System (INIS)

    1984-04-01

    This is a report on a trip to Japan by personnel of the US Nuclear Regulatory Commission in 1983 to exchange information on steam generators of nuclear power plants. Steam generators of Japanese pressurized water reactors have experienced nearly all of the forms of degradation that have been experienced in US recirculating-type steam generators, except for denting and pitting. More tubes have been plugged per year of reactor operation in Japanese than in US steam generators, but much of the Japanese tube plugging is preventative rather than the result of leaks experienced. The number of leaks per reactor year is much smaller for Japanese than for US steam generators. No steam generators have been replaced in Japan while several have been replaced in the US. The Japanese experience may be related to their very stringent inspection and maintenance programs for steam generators

  13. Draining down of a nuclear steam generating system

    International Nuclear Information System (INIS)

    Jawor, J.C.

    1987-01-01

    The method is described of draining down contained reactor-coolant water from the inverted vertical U-tubes of a vertical-type steam generator in which the upper, inverted U-shaped ends of the tubes are closed and the lower ends thereof are open. The steam generator is part of a nuclear powered steam generating system wherein the reactor coolant water is normally circulated from and back into the reactor via a loop comprising the steam generator and inlet and outlet conduits connected to the lower end of the steam generator. The method comprises continuously introducing a gas which is inert to the system and which is under pressure above atmospheric pressure into at least one of the downwardly facing open ends of each of the U-tubes from below the tube sheet in which the open ends of the U-tubes are mounted adjacent the lower end of the steam generator, while permitting the water to flow out from the open ends of the U-tubes

  14. Loss of feed flow, steam generator tube rupture and steam line break thermohydraulic experiments

    International Nuclear Information System (INIS)

    Mendler, O.J.; Takeuchi, K.; Young, M.Y.

    1986-10-01

    The Westinghouse Model Boiler No. 2 (MB-2) steam generator test model at the Engineering Test Facility in Tampa, Florida, was reinstrumented and modified for performing a series of tests simulating steam generator accident transients. The transients simulated were: loss of feed flow, steam generator tube rupture, and steam line break events. This document presents a description of (1) the model boiler and the associated test facility, (2) the tests performed, and (3) the analyses of the test results

  15. Loss of feed flow, steam generator tube rupture and steam line break thermohydraulic experiments

    Energy Technology Data Exchange (ETDEWEB)

    Mendler, O J; Takeuchi, K; Young, M Y

    1986-10-01

    The Westinghouse Model Boiler No. 2 (MB-2) steam generator test model at the Engineering Test Facility in Tampa, Florida, was reinstrumented and modified for performing a series of tests simulating steam generator accident transients. The transients simulated were: loss of feed flow, steam generator tube rupture, and steam line break events. This document presents a description of (1) the model boiler and the associated test facility, (2) the tests performed, and (3) the analyses of the test results.

  16. National report on nuclear power plant control and instrumentation in Czechoslovakia

    International Nuclear Information System (INIS)

    Stirsky, P.; Karpeta, C.

    1986-01-01

    Research, development and design efforts in the field of nuclear power plant I and C systems in Czechoslovakia have been recently aimed at solving the following problems: setting the parameters of the WWER 440 units control and protection systems and testing them in the power phase of commissioning; design and simulation of the WWER 440 units control system performance under the conditions of steam bleeding for a centralized heat supply system; development of a simulation model of the unit WWER 1000 dynamics for the purpose of I and C systems investigation and design; design of innovated I and C systems for WWER 440 and WWER 1000 units

  17. Parametric study for horizontal steam generator modelling

    Energy Technology Data Exchange (ETDEWEB)

    Ovtcharova, I. [Energoproekt, Sofia (Bulgaria)

    1995-12-31

    In the presentation some of the calculated results of horizontal steam generator PGV - 440 modelling with RELAP5/Mod3 are described. Two nodalization schemes have been used with different components in the steam dome. A study of parameters variation on the steam generator work and calculated results is made in cases with separator and branch.

  18. Parametric study for horizontal steam generator modelling

    Energy Technology Data Exchange (ETDEWEB)

    Ovtcharova, I [Energoproekt, Sofia (Bulgaria)

    1996-12-31

    In the presentation some of the calculated results of horizontal steam generator PGV - 440 modelling with RELAP5/Mod3 are described. Two nodalization schemes have been used with different components in the steam dome. A study of parameters variation on the steam generator work and calculated results is made in cases with separator and branch.

  19. Burnup influence on the WWER-1000 reactor vessel neutron fluence evaluation

    International Nuclear Information System (INIS)

    Panayotov, I.; Mihaylov, N.; Ilieva, K.; Kirilova, D.; Manolova, M.

    2009-01-01

    The neutron fluence of the vessels of the reactors is determined regularly accordingly the RPV Surveillance Program of Kozloduy NPP Unit 5 and 6 in order to assess the state of the metal vessel and their radiation damaging. The calculations are carried out by the method of discrete ordinates used in the TORT program for operated reactor cycles. An average reactor spectrum corresponding to fresh U-235 fuel is used as an input neutron source. The impact of the burn up of the fuel on the neutron fluence of WWER-1000 reactor vessel is evaluated. The calculations of isotopic concentrations of U-235 and Pu-239 corresponding to 4 years burn up were performed by the module SAS2H of the code system SCALE 4.4. Since fresh fuel or 4 years burn up fuel assembly are placed in periphery of reactor core the contribution of Pu-239 of first year burn up and of 4 years burn up is taken in consideration. Calculations of neutron fluence were performed with neutron spectrum for fresh fuel, for 1 year and for 4 years burn up fuel. Correction factors for neutron fluence at the inner surface of the reactor vessel, in ? depth of the vessel and in the air behind the vessel were obtained. The correction coefficient could be used when the neutron fluence is assessed so in verification when the measured activity of ex-vessel detectors is compared with calculated ones. (Authors)

  20. Analysis of WWER 1000 collector cracking mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, K.; Wozniak, J. [Vitkovice J.S.C., Ostrava (Switzerland)

    1997-12-31

    The presentation reviews the large experimental program, started in 1993 in Vitkovice, where the main aim was: (1) a detailed study of strain and thermal ageing, dissolved oxygen content and temperature on subcritical crack growth in 10NiMo8.5 (10GN2MFA) steel, (2) a detailed study of the effect of high temperature water and tube expansion technology on fracture behaviour of ligaments between holes for heat exchange tubes, and (3) a detailed study of the effect of drilling, tube expansion technology and heat treatment on residual stresses on the surface of holes for heat exchange tubes. The aim of all these investigations was to find a dominant damage mechanism responsible for collector cracking to be able to judge the efficiency of implemented modifications and suggested countermeasures and to answer a very important question whether proper operation conditions (mainly water chemistry) make the operation of steam generators made in Vitcovice safe throughout the planned lifetime. 10 refs.

  1. Analysis of WWER 1000 collector cracking mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Matocha, K; Wozniak, J [Vitkovice J.S.C., Ostrava (Switzerland)

    1998-12-31

    The presentation reviews the large experimental program, started in 1993 in Vitkovice, where the main aim was: (1) a detailed study of strain and thermal ageing, dissolved oxygen content and temperature on subcritical crack growth in 10NiMo8.5 (10GN2MFA) steel, (2) a detailed study of the effect of high temperature water and tube expansion technology on fracture behaviour of ligaments between holes for heat exchange tubes, and (3) a detailed study of the effect of drilling, tube expansion technology and heat treatment on residual stresses on the surface of holes for heat exchange tubes. The aim of all these investigations was to find a dominant damage mechanism responsible for collector cracking to be able to judge the efficiency of implemented modifications and suggested countermeasures and to answer a very important question whether proper operation conditions (mainly water chemistry) make the operation of steam generators made in Vitcovice safe throughout the planned lifetime. 10 refs.

  2. Steam generator arrangement

    International Nuclear Information System (INIS)

    Ssinegurski, E.

    1981-01-01

    A steam flow path arrangement for covering the walls of the rear gas pass of a steam generator is disclosed. The entire flow passes down the sidewalls with a minor portion then passing up through the rear wall to a superheater inlet header at an intermediate elevation. The major portion of the flow passes up the front wall and through hanger tubes to a roof header. From there the major portion passes across the roof and down the rear wall to the superheater inlet header at the intermediate elevation

  3. CRBRP steam-generator design evolution

    International Nuclear Information System (INIS)

    Geiger, W.R.; Gillett, J.E.; Lagally, H.O.

    1983-01-01

    The overall design of the CRBRP Steam Generator is briefly discussed. Two areas of particular concern are highlighted and considerations leading to the final design are detailed. Differential thermal expansion between the shell and the steam tubes is accommodated by the tubes flexing in the curved section of the shell. Support of the tubes by the internals structure is essential to permit free movement and minimize tube wear. Special spacer plate attachment and tube hole geometry promote unimpeded axial movement of the tubes by allowing individual tubes to rotate laterally and by providing lateral movement of the spacer plates relative to the adjacent support structure. The water/steam heads of the CRBRP Steam Generator are spherical heads welded to the lower and upper tubesheets. They were chosen principally because they provide a positively sealed system and result in more favorable stresses in the tubesheets when compared to mechanically attached steamheads

  4. Wavelet network controller for nuclear steam generators

    International Nuclear Information System (INIS)

    Habibiyan, H; Sayadian, A; Ghafoori-Fard, H

    2005-01-01

    Poor control of steam generator water level is the main cause of unexpected shutdowns in nuclear power plants. Particularly at low powers, it is a difficult task due to shrink and swell phenomena and flow measurement errors. In addition, the steam generator is a highly complex, nonlinear and time-varying system and its parameters vary with operating conditions. Therefore, it seems that design of a suitable controller is a necessary step to enhance plant availability factor. The purpose of this paper is to design, analyze and evaluate a water level controller for U-tube steam generators using wavelet neural networks. Computer simulations show that the proposed controller improves transient response of steam generator water level and demonstrate its superiority to existing controllers

  5. Vibration Analysis for Steam Dryer of APR1400 Steam Generator

    Energy Technology Data Exchange (ETDEWEB)

    Han, Sung-heum; Ko, Doyoung [KHNP CRI, Daejeon (Korea, Republic of); Cho, Minki [Doosan Heavy Industry, Changwon (Korea, Republic of)

    2016-10-15

    This paper is related to comprehensive vibration assessment program for APR1400 steam generator internals. According to U.S. Nuclear Regulatory Commission, Regulatory Guide 1.20 (Rev.3, March 2007), we conducted vibration analysis for a steam dryer as the second steam separator of steam generator internals. The vibration analysis was performed at the 100 % power operating condition as the normal operation condition. The random hydraulic loads were calculated by the computational fluid dynamics and the structural responses were predicted by power spectral density analysis for the probabilistic method. In order to meet the recently revised U.S. NRC RG 1.20 Rev.3, the CVAP against the potential adverse flow effects in APR1400 SG internals should be performed. This study conducted the vibration response analysis for the SG steam dryer as the second moisture separator at the 100% power condition, and evaluated the structural integrity. The predicted alternating stress intensities were evaluated to have more than 17.78 times fatigue margin compared to the endurance limit.

  6. Dynamic modelling of nuclear steam generators

    International Nuclear Information System (INIS)

    Kerlin, T.W.; Katz, E.M.; Freels, J.; Thakkar, J.

    1980-01-01

    Moving boundary, nodal models with dynamic energy balances, dynamic mass balances, quasi-static momentum balances, and an equivalent single channel approach have been developed for steam generators used in nuclear power plants. The model for the U-tube recirculation type steam generator is described and comparisons are made of responses from models of different complexity; non-linear versus linear, high-order versus low order, detailed modeling of the control system versus a simple control assumption. The results of dynamic tests on nuclear power systems show that when this steam generator model is included in a system simulation there is good agreement with actual plant performance. (author)

  7. Future development LMFBR-steam generators SNR2

    International Nuclear Information System (INIS)

    Essebaggers, J.; Pors, J.G.

    1975-01-01

    The development work for steam generators for large LMFBR plants by Neratoom will be reviewed consisting of: 1. Development engineering information. 2. Concept select studies followed by conceptual designs of selected models. 3. Development manufacturing techniques. 4. Detail design of a prototype unit. 5. Testing of sub-constructions for prototype steam generators. In this presentation item 1 and 2 above will be high lighted, identifying the development work for the SNR-2 steam generators on short term basis. (author)

  8. Comparative calculations and operation-to-PIE data juxtaposition of the Zaporozhye NPP, WWER-1000 FA-E0325 fuel rods after 4 years of operation up to ∼49 MWd/kgU burnup

    International Nuclear Information System (INIS)

    Passage, G.; Stefanova, S.; Scheglov, A.; Proselkov, V.

    2006-01-01

    Operational and PIE data for the Zaporozhe NPP, FA-E0325, WWER-1000 fuel rods were provided in the OECD NEA IFPE Database and were used to perform comparative calculations among several fuel performance codes. The fuel rods had been irradiated for 4 years of operation up to ∼49 MWd/kg U burnup. The fuel rod operation histories are developed for the PINw99, TRANSURANUS (V1M1J03) and TOPRA-2 codes. The initial state fuel rod parameters are analysed and calculations are carried out. The PIE data enable the comparison of experimental measurement with code-calculated values for cladding elongation (49 rods), FGR and gas pressure (35 rods). Cladding diameter creep-down and gap closure results are juxtaposed as well. The capability of the applied codes correctly to predict the WWER fuel rod performance is shown. The WWER-1000 fuel rod data include initial geometrical and design parameters of the fuel rods, as well as description of the operation regime, NPP unit loading history and PIE results at normal conditions. The data are sufficient for modelling all 312 fuel rod and for comparison of calculations with experimental results for a limited number of fuel rods. The comparison between the calculated and measured results discussed in this paper shows that the codes PINw99, TRANSURANUS and TOPRA-2, are capable of adequate predicting the thermophysical and the mechanical performance of the WWER-1000 fuel rods. The PINw99 code predicts conservative BOL FGR values and conservative gas pressure values in the region of burnups higher than 30 MWd/kg U, which can be explained by the underprediction of the cladding gas inner volume and cladding elongation. The improved version PIN2K (not applied in the present study) predicts much better FGR and gas pressure, though, it is still under development in the high burnup FGR modelling part. In the TRANSURANUS code, there are also areas, where refinements are clearly indicated. They are subjects of the ongoing research projects and

  9. French steam generator

    International Nuclear Information System (INIS)

    Remond, A.

    1986-01-01

    After recalling the potential damage mode of tubes of steam generator, the author recalls the safety criteria used in France. The improvements and the process of damage prejudice and reparation for tubular bundle are presented [fr

  10. Model studies of the vertical steam generator thermal-hydraulic characteristics

    International Nuclear Information System (INIS)

    Desyatun, V.F.; Moskvichev, V.F.; Ulasov, V.M.; Morozov, V.G.; Burkov, V.K.; Grebennikov, V.N.

    1984-01-01

    Results of investigations conducted to clarify the calculation technique and to test the workability of the main elements and units of the PGV-250 vertical steam generator of saturated steam are considered. The steam generating capacity of the plant is 1486 t/h, thermal power is 792 MW. Steam generation follows a multiple circulation scheme. The heat surface comprises 330-shields. The investigations are carried out with a model which reproduces all the main elements of the steam generator xcluding the economizer section. The flow rates of feed water, generated steam and coolant of the first circuit as well as temperature, pressure and humidity of the generated steam past the separator are determined. The average heat transfer factors of the heat surface are calculated on the base of the data obtained and a conclusion is drawn on the correctness of the thermohydraulic calculation technique used in development of the PGV-250 steam generator design. Temperature pulsations and heat surface steaming are not observed. The steam humidity at the outlet and steam capture into sinking tubes are within permissible values

  11. LMR steam generator blowdown with RETRAN

    International Nuclear Information System (INIS)

    Wei, T.Y.C.

    1985-01-01

    One of the transients being considered in the FSAR Chapter 15 analyses of anticipated LMR transients is the fast blowdown of a steam generator upon inadvertent actuation of the liquid metal/water reaction mitigation system. For the blowdown analysis, a stand-alone steam generator model for the IFR plant was constructed using RETRAN

  12. Research program plan: steam generators

    International Nuclear Information System (INIS)

    Muscara, J.; Serpan, C.Z. Jr.

    1985-07-01

    This document presents a plan for research in Steam Generators to be performed by the Materials Engineering Branch, MEBR, Division of Engineering Technology, (EDET), Office of Nuclear Regulatory Research. It is one of four plans describing the ongoing research in the corresponding areas of MEBR activity. In order to answer the questions posed, the Steam Generator Program has been organized with the three elements of non-destructive examination; mechanical integrity testing; and corrosion, cleaning and decontamination

  13. Water box for steam generator

    International Nuclear Information System (INIS)

    Lecomte, Robert; Viaud, Michel.

    1975-01-01

    This invention relates to a water box for connecting an assembly composed of a vertical steam generator and a vertical pump to the vessel of the nuclear reactor, the assembly forming the primary cooling system of a pressurised water reactor. This invention makes it easy to dismantle the pump on the water box without significant loss of water in the primary cooling system of the reactor and particularly without it being necessary to drain the water contained in the steam generator beforehand. It makes it possible to shorten the time required for dismantling the primary pump in order to service or repair it and makes dismantling safer in that the dismantling does not involve draining the steam generator and therefore the critical storage of a large amount of cooling water that has been in contact with the fuel assemblies of the nuclear reactor core [fr

  14. Three-dimensional modeling of nuclear steam generator

    International Nuclear Information System (INIS)

    Bogdan, Z.; Afgan, N.

    1985-01-01

    In this paper mathematical model for steady-state simulation of thermodynamic and hydraulic behaviour of U-tube nuclear steam generator is described. The model predicts three-dimensional distribution of temperatures, pressures, steam qualities and velocities in the steam generator secondary loop. In this analysis homogeneous two phase flow model is utilized. Foe purpose of the computer implementation of the mathematical model, a special flow distribution code NUGEN was developed. Calculations are performed with the input data and geometrical characteristics related to the D-4 (westinghouse) model of U-tube nuclear steam generator built in Krsko, operating under 100% load conditions. Results are shown in diagrams giving spatial distribution of pertinent variables in the secondary loop. (author)

  15. Steam generator tube rupture effects on a LOCA

    International Nuclear Information System (INIS)

    LaChance, J.L.

    1979-01-01

    A problem currently experienced in commercial operating pressurized water reactors (PWR) in the United States is the degradation of steam generator tubes. Safety questions have arisen concerning the effect of these degraded tubes rupturing during a postulated loss-of-coolant accident (LOCA). To determine the effect of a small number of tube ruptures on the behavior of a large PWR during a postulated LOCA, a series of computer simulations was performed. The primary concern of the study was to determine whether a small number (10 or less of steam generator tubes rupturing at the beginning surface temperatures. Additional reflood analyses were performed to determine the system behavior when from 10 to 60 tubes rupture at the beginning of core reflood. The FLOOD4 code was selected as being the most applicable code for use in this study after an extensive analysis of the capabilities of existing codes to perform simulations of a LOCA with concurrent steam generator tube ruptures. The results of the study indicate that the rupturing of 10 or less steam generator tubes in any of the steam generators during a 200% cold leg break will not result in a significant increase in the peak cladding temperature. However, because of the vaporization of the steam generator secondary water in the primary side of the steam generator, a significant increase in the core pressure occurs which retards the reflooding process

  16. Thermophysical aspects of WWER safety

    International Nuclear Information System (INIS)

    Kolochko, Vladimir N.

    1999-01-01

    The paper presents a review of the main thermophysical aspects of NPPs safety and efficiency increase applied to WWERs. Improvement of operating WWER units is the main short-term and medium-term tasks of the utilities in Ukraine. The new generation of reactors for increasing the reactor facilities efficiency should utilize achievements of thermo physics research results. The thermophysical aspects of NPPs safety and efficiency are envisaged in the context of the atomic energy development strategy. The analysis of thermophysical processes occurring in the core shows that a number of problems concerning boiling crisis and heat exchange intensification during transient and accidents are not solved in spite of numerous calculations and experimental research. The up-to-date safety conception includes severe accidents consideration for safety assessment. Review of severe accidents management is presented. Additional validation of the West advanced thermal hydraulic codes which are applied for WWERs reassessment calculations is required. Contribution of the processes which might occur in WWER containment to safety problems solving is considered as well. (author)

  17. Mathematical modeling of control system for the experimental steam generator

    Science.gov (United States)

    Podlasek, Szymon; Lalik, Krzysztof; Filipowicz, Mariusz; Sornek, Krzysztof; Kupski, Robert; Raś, Anita

    2016-03-01

    A steam generator is an essential unit of each cogeneration system using steam machines. Currently one of the cheapest ways of the steam generation can be application of old steam generators came from army surplus store. They have relatively simple construction and in case of not so exploited units - quite good general conditions, and functionality of mechanical components. By contrast, electrical components and control systems (mostly based on relay automatics) are definitely obsolete. It is not possible to use such units with cooperation of steam bus or with steam engines. In particular, there is no possibility for automatically adjustment of the pressure and the temperature of the generated steam supplying steam engines. Such adjustment is necessary in case of variation of a generator load. The paper is devoted to description of improvement of an exemplary unit together with construction of the measurement-control system based on a PLC. The aim was to enable for communication between the steam generator and controllers of the steam bus and steam engines in order to construction of a complete, fully autonomic and maintenance-free microcogeneration system.

  18. Experience in start-up of the South-Ukrainian-2 power unit with the WWER-1000 reactor

    International Nuclear Information System (INIS)

    Belov, Yu.V.; Kazakov, V.A.; Kirilov, V.V.; Kryakvin, L.V.

    1987-01-01

    The volume, sequence and dates of works fulfilled during hot testing, physical and power start-ups and while bringing output of the South-Ukranian-2 power unit with the WWER-1000 reactor to the design figure are described. The works were fulfilled according to the standard schedules from October in 1984 till April in 1985. Combination of the stages and intensification of works before the physical start-up have allowed to shorten the dates by 90 days as compared to the schedule. The physical and power start-ups, including bringing reactor output to the design figure, were performed during 140 days, that permits to shorten the dates by 20 days more. The results of physical experiments carried out at the South-Ukranian-2 power unit, are in good agreement with the data obtained at the first power units of the given and Kalinin NPPs. Besides, during physical and power start-ups additional measures ensuring nuclear safety are developed

  19. Steam generator tube fitness-for-service guidelines

    International Nuclear Information System (INIS)

    Gorman, J.A.; Harris, J.E.; Lowenstein, D.B.

    1995-07-01

    The objectives of this project were to characterize defect mechanisms which could affect the integrity of steam generator tubes, to review and critique state-of-the-art Canadian and international steam generator tube fitness-for-service criteria and guidelines, and to obtain recommendations for criteria that could be used to assess fitness-for service guidelines for steam generator tubes containing defects in Canadian power plant service. Degradation mechanisms, that could affect CANDU steam generator tubes in Canada, have been characterized. The design standards and safety criteria that apply to steam generator tubing in nuclear power plant service in Canada and in Belgium, France, Japan, Spain, Sweden, and the USA have been reviewed and described. The fitness-for-service guidelines used for a variety of specific defect types in Canada and internationally have been evaluated and described in detail in order to highlight the considerations involved in developing such defect specific guidelines. Existing procedures for defect assessment and disposition have been identified, including inspection and examination practices. The approaches used in Canada and in Belgium, France, Japan, Spain, Sweden, and the USA for fitness-for-service guidelines were compared and contrasted for a variety of defect mechanisms. The strengths and weaknesses of the various approaches have been assessed. The report presents recommendations on approaches that may be adopted in the development of fitness-for-service guidelines for use in the dispositioning of steam generator tubing defects in Canada. (author). 175 refs., 2 tabs., 28 figs

  20. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 5A. Experience data. Working material. Experience database of Romanian facilities subjected to the last three Vrancea earthquakes. Final report from November 1994 - October 1995

    International Nuclear Information System (INIS)

    Coman, O.; Stevenson, J.D.

    1996-01-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains the report experience database for Romanian facilities contingent to the three Vrancea earthquakes

  1. Co-ordinated research programme on benchmark study for the seismic analysis and testing of WWER-type nuclear power plants. V. 5A. Experience data. Working material. Experience database of Romanian facilities subjected to the last three Vrancea earthquakes. Final report from November 1994 - October 1995

    Energy Technology Data Exchange (ETDEWEB)

    Coman, O [Stevenson and Associates Bucharest Office, Bucharest (Romania); Stevenson, J D [Stevenson and Associates (United States)

    1996-07-01

    The Co-ordinated research programme on the benchmark study for the seismic analysis and testing of WWER-type nuclear power plants was initiated subsequent to the request from representatives of Member States. The conclusions adopted at the Technical Committee Meeting on Seismic Issues related to existing nuclear power plants held in Tokyo in 1991 called for the harmonization of methods and criteria used in Member States in issues related to seismic safety. The Consulltants' Meeting which followed resulted in producing a working document for CRP. It was decided that a benchmark study is the most effective way to achieve the principal objective. Two types of WWER reactors (WWER-440/213 and WWER-1000) were selected as prototypes for the benchmark exercise to be tested on a full scale using explosions and/or vibration generators. The two prototypes are Kozloduy Units 5/6 for WWER-1000 and Paks for WWER-440/213 nuclear power plants. This volume of Working material contains the report experience database for Romanian facilities contingent to the three Vrancea earthquakes.

  2. Modeling and Simulation of U-tube Steam Generator

    Science.gov (United States)

    Zhang, Mingming; Fu, Zhongguang; Li, Jinyao; Wang, Mingfei

    2018-03-01

    The U-tube natural circulation steam generator was mainly researched with modeling and simulation in this article. The research is based on simuworks system simulation software platform. By analyzing the structural characteristics and the operating principle of U-tube steam generator, there are 14 control volumes in the model, including primary side, secondary side, down channel and steam plenum, etc. The model depends completely on conservation laws, and it is applied to make some simulation tests. The results show that the model is capable of simulating properly the dynamic response of U-tube steam generator.

  3. Power distribution gradients in WWER type cores and fuel failure root causes

    Energy Technology Data Exchange (ETDEWEB)

    Mikuš, Ján M., E-mail: JanMikus.nrc@hotmail.com

    2014-02-15

    Highlights: • Power (fission rate) distribution gradients can represent fuel failure root causes. • Positions with above gradients were investigated in WWER type cores on reactor LR-0. • Above gradients were evaluated near core heterogeneities and construction materials. • Results can be used for code validation and fuel failure occurrence investigation. - Abstract: Neutron flux non-uniformity and gradients of neutron current resulting in corresponding power (fission rate) distribution changes can represent root causes of the fuel failure. Such situation can be expected in vicinity of some core heterogeneities and construction materials. Since needed data cannot be obtained from nuclear power plant (NPP), results of some benchmark type experiments performed on light water, zero-power research reactor LR-0 were used for investigation of the above phenomenon. Attention was focused on determination of the spatial power distribution changes in fuel assemblies (FAs): Containing fuel rods (FRs) with Gd burnable absorber in WWER-440 and WWER-1000 type cores, Neighboring the core blanket and dummy steel assembly simulators on the periphery of the WWER-440 standard and low leakage type cores, resp., Neighboring baffle in WWER-1000 type cores, and Neighboring control rod (CR) in WWER-440 type cores, namely (a) power peak in axial power distribution in periphery FRs of the adjacent FAs near the area between CR fuel part and butt joint to the CR absorbing part and (b) decrease in radial power distribution in FRs near CR absorbing part. An overview of relevant experimental results from reactor LR-0 and some information concerning leaking FAs on NPP Temelín are presented. Obtained data can be used for code validation and subsequently for the fuel failure occurrence investigation.

  4. Wastage of Steam Generator Tubes by Sodium-Water Reaction

    International Nuclear Information System (INIS)

    Jeong, Ji Young; Kim, Jong Man; Kim, Tae Joon; Choi, Jong Hyeun; Kim, Byung Ho; Lee, Yong Bum; Park, Nam Cook

    2010-01-01

    The Korea Advanced LIquid MEtal Reactor (KALIMER) steam generator is a helical coil, vertically oriented, shell-and-tube type heat exchanger with fixed tube-sheet. The conceptual design and outline drawing of the steam generator are shown in Figure 1. Flow is counter-current, with sodium on the shell side and water/steam on the tube side. Sodium flow enters the steam generator through the upper inlet nozzles and then flows down through the tube bundle. Feedwater enters the steam generator through the feedwater nozzles at the bottom of steam generator. Therefore, if there is a hole or a crack in a heat transfer tube, a leakage of water/steam into the sodium may occur, resulting in a sodium-water reaction. When such a leak occurs, so-called 'wastage' is the result which may cause damage to or a failure of the adjacent tubes. If a steam generator is operated for some time in this condition, it is possible that it might create an intermediate leak state which would then give rise to the problems of a multi-target wastage in a very short time. Therefore, it is very important to predict these phenomena quantitatively from the view of designing a steam generator and its leak detection systems. For this, multi-target wastage tests for modified 9Cr-1Mo steel tube bundle by intermediate leaks are being prepared

  5. Expert system GIP-WWER for verification of seismic adequacy of WWER equipment

    International Nuclear Information System (INIS)

    Masopust, R.

    1999-01-01

    The aim of this report is to describe the modified Generic Implementation Procedure (GIP) titled GIP-WWER which can be used to verify seismic adequacy of the safe shutdown mechanical and electrical equipment and distribution systems of operating or constructed WWER NPPs, namely WWER-440/213 type. The WWER-GIP procedure was prepared using available information contained in GIP and the experience taken from various seismic inspections and evaluations of WWER type NPPs performed in the last five years

  6. Steam generator leak detection using acoustic method

    International Nuclear Information System (INIS)

    Goluchko, V.V.; Sokolov, B.M.; Bulanov, A.N.

    1982-05-01

    The main requirements to meet by a device for leak detection in sodium - water steam generators are determined. The potentialities of instrumentation designed based on the developed requirements have been tested using a model of a 550 kw steam generator [fr

  7. Mathematical modeling of control system for the experimental steam generator

    Directory of Open Access Journals (Sweden)

    Podlasek Szymon

    2016-01-01

    Full Text Available A steam generator is an essential unit of each cogeneration system using steam machines. Currently one of the cheapest ways of the steam generation can be application of old steam generators came from army surplus store. They have relatively simple construction and in case of not so exploited units – quite good general conditions, and functionality of mechanical components. By contrast, electrical components and control systems (mostly based on relay automatics are definitely obsolete. It is not possible to use such units with cooperation of steam bus or with steam engines. In particular, there is no possibility for automatically adjustment of the pressure and the temperature of the generated steam supplying steam engines. Such adjustment is necessary in case of variation of a generator load. The paper is devoted to description of improvement of an exemplary unit together with construction of the measurement-control system based on a PLC. The aim was to enable for communication between the steam generator and controllers of the steam bus and steam engines in order to construction of a complete, fully autonomic and maintenance-free microcogeneration system.

  8. Embalse steam generators - status in 2009

    International Nuclear Information System (INIS)

    Luna, P.; Yetisir, M.; Roy, S.; MacEacheron, R.

    2009-01-01

    The Embalse Nuclear Generating Station (ENGS) is a CANDU 6, a pressurized heavy water plant, with a net capacity of 648 MW. The primary heat transport system at Embalse includes four Steam Generators (SGs) manufactured by Babcock and Wilcox Canada (B and W). These steam generators are vertical recirculating heat exchangers with Incoloy 800 inverted U-tubes and an integral preheater. Embalse SGs performed very well until the late 1990s, when an increase in tube fretting was noticed in the U-bend region. In-service inspection in 2002 and 2004 confirmed that the cause of the tube fretting was flow accelerated corrosion (FAC) damage of scallop bar supports in the U-bend region. The straight leg tube support plates (TSPs) have also been degrading. Degradation was worst at the top support plates, and it was in the form of material loss on the cold leg. The hot leg TSPs were heavily fouled with deposits and flow areas were blocked. Visual inspections and subsequent studies showed that the cause of the TSP degradation was also FAC. The Embalse SGs have carbon steel supports that make them susceptible to FAC. To mitigate the effects of degraded tube support structures, three additional sets of anti-vibration bars were installed in the U-bend regions of all four steam generators in 2004. In 2007, an improved secondary-side chemistry specification was implemented to reduce the FAC rate and the hot leg TSPs was waterlanced. A root cause analysis and condition assessment was performed for the tube supports in 2007. Fitness for Service (FFS) evaluation was completed using the Canadian Industry Guidelines for steam generator tubes. The steam generators were returned to service and the plan has operated without another forced outage to date. The FAC degradation of the carbon steel U-bend tube support systems has had the most significant impact on the plant operation causing a number of forced outages. The discovery of the extent of TSP degradation and difficulties to repair TSPs

  9. Mechanical design of a sodium heated steam generator

    International Nuclear Information System (INIS)

    Chetal, S.C.

    1975-01-01

    FBTR steam generator is a once through type unit consisting of four 12.5 MW thermal modules generating a total of 74 tons per hour of steam at 125 bar and 480 0 C. This paper outlines the mechanical design of such type of steam generator with emphasis on special design problems associated with this type of sodium to water steam heat exchanger, namely, thermal cycling of transition zone where nucleate boiling changes over to film boiling, application of pressure vessel design criteria for transient pressures, thermal stress evaluation resulting from differential expansion between shell and tube in this typical configuration, sodium headers support design, thermal sleeve, design, thermal shock analysis in thick tubes, thermal stress resulting from stratification and stability of expansion bends against vibration. Some of the possible design changes for the future large size steam generator are outlined. (author)

  10. Consolidated nuclear steam generator

    International Nuclear Information System (INIS)

    Jabsen, F.S.; Schluderberg, D.C.; Paulson, A.E.

    1978-01-01

    An improved system of providing power has a unique generating means for nuclear reactors with a number of steam generators in the form of replaceable modular units of the expendable type to attain the optimum in effective and efficient vaporization of fluid during the generating power. The system is most adaptable to undrground power plants and marine usage

  11. Transient simulations in WWER-1000-comparison between DYN3D-ATHLET and DYN3D-RELAP5

    International Nuclear Information System (INIS)

    Grundmann, U.; Kliem, S.; Kozmenkov, Y.; Mittag, S.; Rohde, U.; Weiss, F.P.

    2003-01-01

    Simulations of a real transient of an operating WWER-1000 power plant have been performed using DYN3D-ATHLET (Gru95) and DYN3D-RELAP5 (Koy01) code systems in the frame of activities aimed at a validation of the neutronic / thermal-hydraulic coupled codes. The transient initiated by a main coolant pump switching off, when three of the four main coolant pumps of the plant are in operation (scenario of the VALCO project) is chosen for the simulation. The same models of the plant (except the core nodalization) but two different libraries of macroscopic cross-sections have been used in compared calculations. Additionally, the compared code systems are based on the different / external and internal / coupling techniques. This paper contains a brief description of the coupled codes and the plant model as well as a comparison between the results from simulations (Authors)

  12. Steam generator replacement in Bruce A Unit 1 and Unit 2

    International Nuclear Information System (INIS)

    Hart, R.S.

    2006-01-01

    The Bruce A Generating Station consists of four 900 MW class CANDU units. The reactor and Primary Heat Transport System for each Unit are housed within a reinforced concrete reactor vault. A large duct running below the reactor vaults accommodates the shared fuel handling system, and connects the four reactor vaults to the vacuum building. The reactor vaults, fuelling system duct and the vacuum building constitute the station vacuum containment system. Bruce A Unit 2 was shut down in 1995 and Bruce A Units 1, 3 and 4 were shutdown in 1997. Bruce A Units 3 and 4 were returned to service in late 2003 and are currently operating. Units 1 and 2 remain out of service. Bruce Power is currently undertaking a major rehabilitation of Bruce A Unit 1 and Units 2 that will extend the in-service life of these units by at least 25 years. Replacement of the Steam Generators (eight in each unit) is required; this work was awarded to SNC-Lavalin Nuclear (SLN). The existing steam drums (which house the steam separation and drying equipment) will be retained. Unit 2 is scheduled to be synchronized with the grid in 2009, followed by Unit 1 in 2009. Each Bruce A unit has two steam generating assemblies, one located above and to each end of the reactor. Each steam generating assembly consists of a horizontal cylindrical steam drum and four vertical Steam Generators. The vertical Steam Generators connect to individual nozzles that are located on the underside of the Steam Drum (SD). The steam drums are located in concrete shielding structures (steam drum enclosures). The lower sections of the Steam Generators penetrate the top of the reactor vaults: the containment pressure boundary is established by bellows assemblies that connect between the reactor vault roof slab and the Steam Generators. Each Steam Generators is supported from the bottom by a trapeze that is suspended from the reactor vault top structure. The Steam Generator Replacement (SGR) methodology developed by SLN for Unit 1

  13. Steam generator tube integrity program. Phase I report

    International Nuclear Information System (INIS)

    Alzheimer, J.M.; Clark, R.A.; Morris, C.J.; Vagins, M.

    1979-09-01

    The results are presented of the pressure tests performed as part of Phase I of the Steam Generator Tube Integrity (SGTI) program at Battelle Pacific Northwest Laboratory. These tests were performed to establish margin-to-failure predictions for mechanically defected Pressurized Water Reactor (PWR) steam generator tubing under operating and accident conditions. Defect geometries tested were selected because they simulate known or expected defects in PWR steam generators. These defect geometries are Electric Discharge Machining (EDM) slots, elliptical wastage, elliptical wastage plus through-wall slot, uniform thinning, denting, denting plus uniform thinning, and denting plus elliptical wastage. All defects were placed in tubing representative of that currently used in PWR steam generators

  14. Computational comparison of the effect of mixing grids of 'swirler' and 'run-through' types on flow parameters and the behavior of steam phase in WWER fuel assemblies

    International Nuclear Information System (INIS)

    Shcherbakov, S.; Sergeev, V.

    2011-01-01

    The results obtained using the TURBOFLOW computer code are presented for the numerical calculations of space distributions of coolant flow, heating and boiling characteristics in WWER fuel assemblies with regard to the effect of mixing grids of 'Swirler' and 'Run-through' types installed in FA on the above processes. The nature of the effect of these grids on coolant flow was demonstrated to be different. Thus, the relaxation length of cross flows after passing a 'Run-through' grid is five times as compared to a 'Swirler'-type grid, which correlates well with the experimental data. At the same time, accelerations occurring in the flow downstream of a 'Swirler'-type grid are by an order of magnitude greater than those after a 'Run-through' grid. As a result, the efficiency of one-phase coolant mixing is much higher for the grids of 'Run-through' type, while the efficiency of steam removal from fuel surface is much higher for 'Swirler'-type grids. To achieve optimal removal of steam from fuel surface it has been proposed to install into fuel assemblies two 'Swirler'-type grids in tandem at a distance of about 10 cm from each other with flow swirling in opposite directions. 'Run-through' grids would be appropriate for use for mixing in fuel assemblies with a high non-uniformity of fuel-by-fuel power generation. (authors)

  15. Perspective of the Westinghouse steam generator secondary side maintenance approach

    Energy Technology Data Exchange (ETDEWEB)

    Ramaley, D. [Westinghouse Electric Company LLC, Cranberry Township, Pennsylvania (United States)

    2012-07-01

    Historically, Westinghouse had developed a set of steam generator secondary maintenance guidelines focused around performing recurring activities each outage without direct regards to the age, deposit loading, operational status, or corrosion status of the steam generator. Through the evolution of steam generator design and steam generator condition data, Westinghouse now uses a proactive assessment and planning approach for utilities. Westinghouse works with utilities to develop steam generator secondary maintenance plans for long term steam generator viability. Westinghouse has developed a portfolio of products to allow utilities to optimize steam generator operability and develop programs aimed at maintaining the steam generator secondary side in a favorable condition for successful long term operation. Judicious use of the means available for program development should allow for corrosion free operation, long term full power operation at optimum thermal efficiency, and leveling of outage expenditures over a long period of time. This paper will review the following required elements for an effective steam generator secondary side strategy: • Assessment: In order to develop an appropriate maintenance strategy, actions must be taken to obtain an accurate picture of the SG secondary side condition. • Forecasting: Using available data predictions are developed for future steam generator conditions and required maintenance actions. • Action: Cost effective engineering and maintenance actions must be completed at the appropriate time as designated by the plan. • Evaluation of Results: Following execution of maintenance tactics, it is necessary to revise strategy and develop technology enhancements as appropriate. (author)

  16. Double wall steam generator tubing

    International Nuclear Information System (INIS)

    Padden, T.R.; Uber, C.F.

    1983-01-01

    Double-walled steam generator tubing for the steam generators of a liquid metal cooled fast breeder reactor prevents sliding between the surfaces due to a mechanical interlock. Forces resulting from differential thermal expansion between the outer tube and the inner tube are insufficient in magnitude to cause shearing of base metal. The interlock is formed by jointly drawing the tubing, with the inside wall of the outer tube being already formed with grooves. The drawing causes the outer wall of the inner tube to form corrugations locking with the grooves. (author)

  17. PWR and WWER fuel performance. A comparison of major characteristics

    International Nuclear Information System (INIS)

    Weidinger, H.

    2006-01-01

    PWR and WWER fuel technologies have the same basic performance targets: most effective use of the energy stored in the fuel and highest possible reliability. Both fuel technologies use basically the same strategies to reach these targets: 1) Optimized reload strategies; 2) Maximal use of structural material with low neutron cross sections; 3) Decrease the fuel failure frequency towards a 'zero failure' performance by understanding and eliminating the root causes of those defects. The key driving force of the technology of both, PWR and WWER fuel is high burn-up. Presently a range of 45 - 50 MWD/kgU have been reached commercially for PWR and WWER fuel. The main technical limitations to reach high burn-up are typically different for PWR and WWER fuel: for PWR fuel it is the corrosion and hydrogen uptake of the Zr-based materials; for WWER fuel it is the mechanical and dimensional stability of the FA (and the whole core). Corrosion and hydrogen uptake of Zr-materials is a 'non-problem' for WWER fuel. Other performance criteria that are important for high burn-up are the creep and growth behaviour of the Zr materials and the fission gas release in the fuel rod. There exists a good and broad data base to model and design both fuel types. FA and fuel rod vibration appears to be a generic problem for both fuel types but with more evidence for PWR fuel performance reliability. Grid-to-rod fretting is still a major issue in the fuel failure statistics of PWR fuel. Fuel rod cladding defects by debris fretting is no longer a key problem for PWR fuel, while it still appears to be a significant root cause for WWER fuel failures. 'Zero defect' fuel performance is achievable with a high probability, as statistics for US PWR and WWER-1000 fuel has shown

  18. Coal fired steam generation for heavy oil recovery

    International Nuclear Information System (INIS)

    Firmin, K.

    1992-01-01

    In Alberta, some 21,000 m 3 /d of heavy oil and bitumen are produced by in-situ recovery methods involving steam injection. The steam generation requirement is met by standardized natural-gas-fired steam generators. While gas is in plentiful supply in Alberta and therefore competitively priced, significant gas price increases could occur in the future. A 1985 study investigating the alternatives to natural gas as a fuel for steam generation concluded that coal was the most economic alternative, as reserves of subbituminous coal are not only abundant in Alberta but also located relatively close to heavy oil and bitumen production areas. The environmental performance of coal is critical to its acceptance as an alternate fuel to natural gas, and proposed steam generator designs which could burn Alberta coal and control emissions satisfactorily are assessed. Considerations for ash removal, sulfur dioxide sorption, nitrogen oxides control, and particulate emission capture are also presented. A multi-stage slagging type of coal-fired combustor has been developed which is suitable for application with oilfield steam generators and is being commissioned for a demonstration project at the Cold Lake deposit. An economic study showed that the use of coal for steam generation in heavy oil in-situ projects in the Peace River and Cold Lake areas would be economic, compared to natural gas, at fuel price projections and design/cost premises for a project timing in the mid-1990s. 7 figs., 3 tabs

  19. Modernization in-core monitoring system, of WWER-1000 reactors (W-320) by fuel assemblies with individual characteristics using

    International Nuclear Information System (INIS)

    Mitin, V. I.; Semchenkov, J. M.; Kalinushkin, A. E.

    2007-01-01

    The present report covers object, conception, engineering solution of construction of modern system of high-powered reactor in-core control, including WWER-1000 (V-320) reactors. It is known that ICMS main task is on-line monitoring distribution of power release field and its functioning independently of design programs to avoid common reason error. It is shown in what way field of power release recovery has been carrying on; rest on the signals of in-core neutron and temperature sensors. On the base of the obtained and refined information there have being automatically generated signals of preventive and emergency protection on local parameters (linear power to the maximum intensive fuel elements, reserve to heat exchange crisis, 'picking factor'). There have represented technology on sensors and processing methods of SPND and TC signals, ICIS composition and structure, program hard ware, system and applied software. Structure, composition and the taken decisions allow combining class 1E and class B and C tasks in accordance with international norms of separation and safety classes' realization. At present ICIS-M is a system, providing implementation of control, safety, information and diagnostic functions, which allow securing actual increase of quality, reliability and safety in operation of nuclear fuel and NPP units. And at the same time it reduces human factor negative influence to core work thermo technical eliability in the operational process (Authors)

  20. Forming a cohesive steam generator maintenance strategy

    International Nuclear Information System (INIS)

    Poudroux, G.

    1991-01-01

    In older nuclear plants, steam generator tube bundles are the most fragile part of the reactor coolant system. Steam generator tubes are subject to numerous types of loading, which can lead to severe degradation (corrosion and wear phenomena). Preventive actions, such as reactor coolant temperature reduction or increasing the plugging limit and their associated analyses, can increase steam generator service life. Beyond these preventive actions, the number of affected tubes and the different locations of the degradations that occur often make repair campaigns necessary. Framatome has developed and qualified a wide range of treatment and repair processes. They enable careful management of the repair campaigns, to avoid reaching the maximum steam generator tube plugging limit, while optimizing the costs. Most of the available repair techniques allow a large number of affected tubes to be treated. Here we look only at those techniques that should be taken into account when defining a maintenance strategy. (author)

  1. Condensate polisher application for PWR steam generator corrosion control

    International Nuclear Information System (INIS)

    Sawochka, S.G.; Leibovitz, J.; Siegwarth, D.P.; Pearl, W.L.

    1981-01-01

    The evolution of corrosion attack modes particularly in recirculating U-tube PWR steam generators has dictated a thorough review of the advantages and disadvantages of condensate polishing. Analytical modeling techniques to qualitatively predict crevice chemistry variations resulting from steam generator bulk water variations have allowed valuable insights to be developed. Modeling results complemented by steam generator and laboratory corrosion data will be employed to set condensate demineralizer effluent specifications consistent with control of steam generator corrosion. Laboratory and plant studies are being performed to demonstrate achievability of necessary effluent specifications. (author)

  2. Babcock and Wilcox Canada steam generators past, present and future

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J.C. [Babcock and Wilcox Canada, Cambridge, Ontario (Canada)

    1998-07-01

    The steam generators in all of the domestic CANDU Plants, and most of the foreign CANDU plants, were supplied by Babcock and Wilcox Canada, either on their own or in co-operation with local manufacturers. More than 200 steam generators have been supplied. In addition, Babcock and Wilcox Canada has taken the technology which evolved out of the CANDU steam generators and has adapted the technology to supply of replacement steam generators for PWR's. There is enough history and operating experience, plus laboratory experience, to point to the future directions which will be taken in steam generator design. This paper documents the steam generators which have been supplied, the experience in operation and maintenance, what has worked and not worked, and how the design, materials, and operating and maintenance philosophy have evolved. The paper also looks at future requirements in the market, and the continuing research and product development going on at Babcock and Wilcox to address the future steam generator requirements. (author)

  3. Babcock and Wilcox Canada steam generators past, present and future

    International Nuclear Information System (INIS)

    Smith, J.C.

    1998-01-01

    The steam generators in all of the domestic CANDU Plants, and most of the foreign CANDU plants, were supplied by Babcock and Wilcox Canada, either on their own or in co-operation with local manufacturers. More than 200 steam generators have been supplied. In addition, Babcock and Wilcox Canada has taken the technology which evolved out of the CANDU steam generators and has adapted the technology to supply of replacement steam generators for PWR's. There is enough history and operating experience, plus laboratory experience, to point to the future directions which will be taken in steam generator design. This paper documents the steam generators which have been supplied, the experience in operation and maintenance, what has worked and not worked, and how the design, materials, and operating and maintenance philosophy have evolved. The paper also looks at future requirements in the market, and the continuing research and product development going on at Babcock and Wilcox to address the future steam generator requirements. (author)

  4. Conceptual design of once-through helical steam generator for SMART

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Wan; Kim, J. I.; Kim, J. H. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-12-01

    Conceptual design of once-through helical steam generator for the integral reactor SMART is developed. The once-through helical steam generator requires quite different design concepts from the steam generators used in loop type commercial reactors. In this study the design requirements satisfying the operating conditions of the steam generator are derived, and the arrangements and the dimensions of the major parts are determined. By describing the design procedure, the cost of redesign and the costs of developments of similar new steam generators are minimized. The three dimensional models developed make it possible to preview the interferences of the steam generator components and to minimize the possibility of significant design changes in the next design stage by the preliminary strength analysis of the major parts. A methodology for evaluation of flow induced vibration of steam generator tubes has been developed and a preliminary flow induced vibration analysis has been performed. 24 refs., 54 figs., 9 tabs. (Author)

  5. Dismantling of the 50 MW steam generator test facility

    International Nuclear Information System (INIS)

    Nakai, S.; Onojima, T.; Yamamoto, S.; Akai, M.; Isozaki, T.; Gunji, M.; Yatabe, T.

    1997-01-01

    We have been dismantling the 50MW Steam Generator Test Facility (50MWSGTF). The objectives of the dismantling are reuse of sodium components to a planned large scale thermal hydraulics sodium test facility and the material examination of component that have been operated for long time in sodium. The facility consisted of primary sodium loop with sodium heater by gas burner as heat source instead of reactor, secondary sodium loop with auxiliary cooling system (ACS) and water/steam system with steam temperature and pressure reducer instead of turbine. It simulated the 1 loop of the Monju cooling system. The rated power of the facility was 50MWt and it was about 1/5 of the Monju power plant. Several sodium removal methods are applied. As for the components to be dismantled such as piping, intermediate heat exchanger (IHX), air cooled heat exchangers (AC), sodium is removed by steam with nitrogen gas in the air or sodium is burned in the air. As for steam generators which material tests are planned, sodium is removed by steam injection with nitrogen gas to the steam generator. The steam generator vessel is filled with nitrogen and no air in the steam generator during sodium removal. As for sodium pumps, pump internal structure is pulled out from the casing and installed into the tank. After the installation, sodium is removed by the same method of steam generator. As for relatively small reuse components such as sodium valves, electromagnet flow meters (EMFs) etc., sodium is removed by alcohol process. (author)

  6. Chemical cleaning - essential for optimal steam generator asset management

    International Nuclear Information System (INIS)

    Ammann, Franz

    2009-01-01

    Accumulation of deposits in Steam Generator is intrinsic during the operation of Pressurized Water Reactors. Such depositions lead to reduction of thermal performance, loss of component integrity and, in some cases, to power restrictions. Accordingly, removal of such deposits is an essential part of the asset management program of Steam Generators. Every plant has specific conditions, history and constraints which must be considered when planning and performing a chemical cleaning. Typical points are: -Constitution of the deposits or sludge - Sludge load - Sludge distribution in the steam generator - Existing or expected corrosion problems - Amount and tendency of fouling for waste treatment The strategy for chemical cleaning is developed from these points. The range of chemical cleaning treatments starts with very soft cleanings which can remove approximately 100kg per steam generator and ends with full scale, i.e., hard, cleanings which can remove several thousand kilograms of deposits from a steam generator. Dependent upon the desired goal for the operating plant and the steam generator material condition, the correct cleaning method can be selected. This requires flexible cleaning methods that can be adapted to the individual needs of a plant. Such customizing of chemical cleaning methods is a crucial factor for an optimized asset management program of steam generators in a nuclear power plant

  7. Steam generator replacement in Bruce A Unit 1 and Unit 2

    International Nuclear Information System (INIS)

    Hart, R.S.

    2007-01-01

    The Bruce A Generating Station consists of four 900 MW class CANDU units. The reactor and Primary Heat Transport System for each Unit are housed within a reinforced concrete reactor vault. A large duct running below the reactor vaults accommodates the shared fuel handling system, and connects the four reactor vaults to the vacuum building. The reactor vaults, fuelling system duct and the vacuum building constitute the station vacuum containment system. Bruce A Unit 2 was shut down in 1995 and Bruce A Units 1, 3 and 4 were shutdown in 1997. Bruce A Units 3 and 4 were returned to service in late 2003 and are currently operating. Units 1 and 2 remain out of service. Bruce Power is currently undertaking a major rehabilitation of Bruce A Unit 1 and Unit 2 that will extend the in-service tile of these units by at least 25 years. Replacement of the Steam Generators (eight in each unit) is required; this work was awarded to SNC-Lavalin Nuclear (SLN). The existing steam drums (which house the steam separation and drying equipment) will be retained. Unit 2 is scheduled to be synchronized with the grid in 2009, followed by Unit 1 in 2009. Each Bruce A unit has two steam generating assemblies, one located above and to each end of the reactor. Each steam generating assembly consists of a horizontal cylindrical steam drum and four vertical Steam Generators. The vertical Steam Generators connect to individual nozzles that are located on the underside of the Steam Drum (SD). The steam drums are located in concrete shielding structures (steam drum enclosures). The lower sections of the Steam Generators penetrate the top of the reactor vaults: the containment pressure boundary is established by bellows assemblies that connect between the reactor vault roof slab and the Steam Generators. Each Steam Generators is supported from he bottom by a trapeze that is suspended from the reactor vault top structure. The Steam Generator Replacement (SGR) methodology developed by SLN for Unit 1

  8. Modelling of steam condensation in the primary flow channel of a gas-heated steam generator

    International Nuclear Information System (INIS)

    Kawamura, H.; Meister, G.

    1982-10-01

    A new simulation code has been developed for the analysis of steam ingress accidents in high temperatures reactors which evaluates the heat transfer in a steam generator headed by a mixture of helium and water steam. Special emphasis is laid on the analysis of steam condensation in the primary circuit of the steam generator. The code takes wall and bulk condensation into account. A new method is proposed to describe the entrainment of water droplets in the primary gas flow. Some typical results are given. Steam condensation in the primary channel may have a significant effect on temperature distributions. The effect on the heat transferred by the steam generator, however, is found to be not so prominent as might be expected. The reason is discussed. A simplified code will also be described, which gives results with reasonable accuracy within much shorter execution times. This code may be used as a program module in a program simulating the total primary circuit of a high temperature reactor. (orig.) [de

  9. Optimum fuel allocation in parallel steam generator systems

    International Nuclear Information System (INIS)

    Bollettini, U.; Cangioli, E.; Cerri, G.; Rome Univ. 'La Sapienza'; Trento Univ.

    1991-01-01

    An optimization procedure was developed to allocate fuels into parallel steam generators. The procedure takes into account the level of performance deterioration connected with the loading history (fossil fuel allocation and maintenance) of each steam generator. The optimization objective function is the system hourly cost, overall steam demand being satisfied. Costs are due to fuel and electric power supply and to plant depreciation and maintenance as well. In order to easily updata the state of each steam generator, particular care was put in the general formulation of the steam production function by adopting a special efficiency-load curve description based on a deterioration scaling parameter. The influence of the characteristic time interval length on the optimum operation result is investigated. A special implementation of the method based on minimum cost paths is suggested

  10. Methodology for qualification of in-service inspection systems for WWER nuclear power plants. A publication of the extrabudgetary programme on the safety of WWER and RBMK nuclear power plants

    International Nuclear Information System (INIS)

    1998-03-01

    Program was initiated by IAEA in 1990 with the aim to assist the countries of Central and Eastern Europe and former Soviet Union in evaluating the safety of their first generation WWER-440/230 nuclear power plants. The main objectives were: to identify major design and operational safety issues; to establish international consensus on priorities for safety improvements; and to provide assistance in the review of the competence and and adequacy of safety improvement programs. The scope was extended in 1992 to include RBMK, WWER-440/312 and WWER-1000 plants in operation and under construction. Integrity of primary circuit is fundamental for the safe operation of any nuclear power plant. In-service inspection (ISI) in general terms and in particular, non-destructive tests (NDT) play a key role in maintaining primary circuit integrity. This report provides a methodology for qualification of ISI systems which might be used by WWER operating countries as a commonly accepted basis for further development of the necessary qualification related infrastructures. It also provides several qualification principles defining the administrative framework needed for the practical implementation of the methodology, a description of the process of qualification of an inspection system, specifying its minimum technical and documentation related requirements, as well as specific requirements with regard to the NDT procedures, equipment and personnel to be qualified and the test specimen to be used in practical trials. Finally, the report suggests an appropriate distribution of responsibilities among all the parties involved in a qualification process, based on international practice

  11. The Creys Malville FBR Super Phenix steam generators

    International Nuclear Information System (INIS)

    Baque, P.; Zuber, T.; Saur, J.M.; Cambillard, E.

    1980-08-01

    After briefly recalling the French experience on sodium steam generators, the authors describe the design concepts of the Superphenix units and give their main characteristics. A short summary of the realized R and D program precedes the description of the four 750-MWt steam generators, the fabrication of which is in progress by Creusot-Loire at Chalon sur Saone (France). The studies started for the next French fast breeder reactors and their steam generators are mentioned

  12. Research perspectives on the evaluation of steam generator tube integrity

    International Nuclear Information System (INIS)

    Muscara, J.; Diercks, D. R.; Majumdar, S.; Kupperman, D. S.; Bakhtiari, S.; Shack, W. J.

    2001-01-01

    Industry effects have been largely successful in managing degradation of steam generator tubes due to wastage, pitting, and denting, but fretting, SCC and intergranular attack have proved more difficult to manage. Although steam generator replacements are proceeding there is substantial industry interest in operating with degraded steam generators, and significant numbers of plants will continue to do so. In most cases degradation of steam generator tubing by stress corrosion cracking is still managed by plug or repair on detection, because current NDE techniques for characterization of flaws are not accurate enough to permit continued operation. This paper reviews some of the historical background that underlies current steam generator degradation management strategies and outlines some of the additional research that must be done to provide more effective management of degradation in current generators and provide greater assurance of satisfactory performance in replacement steam generators

  13. Third international seminar on horizontal steam generators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The Third International Seminar on Horizontal Steam Generators held on October 18-20, 1994 in Lappeenranta, consisted of six sessions dealing with the topics: thermal hydraulic experiments and analyses, primary collector integrity, management of primary-to-secondary leakage accidents, feedwater collector replacement and discussion of VVER-440 steam generator safety issues.

  14. Third international seminar on horizontal steam generators

    International Nuclear Information System (INIS)

    1995-01-01

    The Third International Seminar on Horizontal Steam Generators held on October 18-20, 1994 in Lappeenranta, consisted of six sessions dealing with the topics: thermal hydraulic experiments and analyses, primary collector integrity, management of primary-to-secondary leakage accidents, feedwater collector replacement and discussion of VVER-440 steam generator safety issues

  15. Third international seminar on horizontal steam generators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    The Third International Seminar on Horizontal Steam Generators held on October 18-20, 1994 in Lappeenranta, consisted of six sessions dealing with the topics: thermal hydraulic experiments and analyses, primary collector integrity, management of primary-to-secondary leakage accidents, feedwater collector replacement and discussion of VVER-440 steam generator safety issues.

  16. Highly Flexible and Efficient Solar Steam Generation Device.

    Science.gov (United States)

    Chen, Chaoji; Li, Yiju; Song, Jianwei; Yang, Zhi; Kuang, Yudi; Hitz, Emily; Jia, Chao; Gong, Amy; Jiang, Feng; Zhu, J Y; Yang, Bao; Xie, Jia; Hu, Liangbing

    2017-08-01

    Solar steam generation with subsequent steam recondensation has been regarded as one of the most promising techniques to utilize the abundant solar energy and sea water or other unpurified water through water purification, desalination, and distillation. Although tremendous efforts have been dedicated to developing high-efficiency solar steam generation devices, challenges remain in terms of the relatively low efficiency, complicated fabrications, high cost, and inability to scale up. Here, inspired by the water transpiration behavior of trees, the use of carbon nanotube (CNT)-modified flexible wood membrane (F-Wood/CNTs) is demonstrated as a flexible, portable, recyclable, and efficient solar steam generation device for low-cost and scalable solar steam generation applications. Benefitting from the unique structural merits of the F-Wood/CNTs membrane-a black CNT-coated hair-like surface with excellent light absorbability, wood matrix with low thermal conductivity, hierarchical micro- and nanochannels for water pumping and escaping, solar steam generation device based on the F-Wood/CNTs membrane demonstrates a high efficiency of 81% at 10 kW cm -2 , representing one of the highest values ever-reported. The nature-inspired design concept in this study is straightforward and easily scalable, representing one of the most promising solutions for renewable and portable solar energy generation and other related phase-change applications. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. The BN-1800 advanced sodium cooled fast reactor meeting requirements to nuclear power engineering of the XXI century

    International Nuclear Information System (INIS)

    Poplavskij, V.M.; Tsibulya, A.M.; Kamaev, A.A.

    2004-01-01

    Basic principles and direction of the elaboration of sodium fast reactor BN-1800 are discussed. The elaboration of the BN-1800 reactor is based on the scientific justified technical feasibilities of BN-350, BN-600 and BN-800 reactors. Descriptions of power blocks and reactor core of the elaborated reactor are presented. Characteristics of the BN-1800 steam generator are given. Safety of reactor unit is estimated, fundamental technical and economic indexes of BN-1800 are discussed. Economic indexes of the BN-1800 reactor are noted to be on the level of WWER-1000 and WWER-1500 reactors [ru

  18. AER working group D on WWER safety analysis - report of the 2007 meeting

    International Nuclear Information System (INIS)

    Kliem, S.

    2007-01-01

    The AER working group D on WWER reactor safety analysis held its sixteenth meeting in Paris, France during the period 08-09 May 2007. The meeting was hosted by the CEA France. It followed the final workshop on the OECD/DOE/CEA WWER-1000 Coolant Transient Benchmark held at 07 May. Altogether 11 participants attend the meeting of the working group D, 7 from AER member organizations and 4 guests from non-member organizations. The co-ordinator of the working group, Mr. S. Kliem, served as chairman of the meeting. The meeting started with a general information exchange about the recent activities in the participating organizations. The given presentations and the discussions can be attributed to the following topics: -Code development and benchmarking for reactor dynamics applications; -Safety analysis methodology and results; -Future activities. New solutions for three different benchmarks were presented and discussed. These are the Second AER Dynamic Benchmark on control rod ejection at hot zero power (S. Kliem, FZD), the WWER-1000 Coolant Transient Benchmark (E. Syrjaelahti, VTT) and the stationary AER-FCM101 Benchmark considering a WWER-1000 reactor (C. Parisi, UniPisa). A. Kereszturi (AEKI) presented a statistical evaluation of the possibility to observe a fuel assembly mis loading event. The second presentation of E. Syrjaelahti was dedicated to the description how best-estimate coupled code calculations at VTT are supported by uncertainty and sensitivity analyses. K. Velkov (GRS) presented preliminary results of BIPR8KN/ATHLET calculations with a very detailed resolution of the calculation grid on the assessment of coolant mixing inside WWER-1000 assembly heads. Coolant mixing experiments at three different mixing test facilities, modeling different reactor types, were presented and compared by S. Kliem. A calculation study using the coupled code system KORSAR/GP on the consequences of the injection of a slug of un borated water into the reactor core was

  19. Steam generator thermal-hydraulics

    International Nuclear Information System (INIS)

    Inch, W.W.; Scott, D.A.; Carver, M.B.

    1980-01-01

    This paper discusses a code for detailed numerical modelling of steam generator thermal-hydraulics, and describes related experimental programs designed to promote in-depth understanding of three-dimensional two-phase flow. (auth)

  20. Development of steam generator manufacturing technology

    International Nuclear Information System (INIS)

    Grant, J.A.

    1979-01-01

    In 1968 Babcock and Wilcox (Operations) Ltd., received an order from the CEGB to design, manufacture, install and commission 16 Steam Generators for 2 x 660 Mw (e) Advanced Gas Cooled Reactor Power Station at Hartlepool. This order was followed in 1970 by a similar order for the Heysham Power Station. The design and manufacture of the Steam Generators represented a major advance in technology and the paper discusses the methods by which a manufacturing facility was developed, by the Production Division of Babcock, to produce components to a quality, complexity and accuracy unique in the U.K. commercial boilermaking industry. The discussion includes a brief design background, a description of the Steam Generators and a view of the Production Division background. This is followed by a description of the organisation of the technological development and a consideration of the results. (author)

  1. Organization and mechanization of maintenance operations at NPPs with the WWER type reactors

    International Nuclear Information System (INIS)

    Titov, A.A.

    1983-01-01

    The structure of capital investments defining organization and mechanization of maintepance operations at NPPs with the WWER type reactors is analyzed. The trends in development of optimum decisions for organization and mechanization of repair obs at NPPs being designed taking into account the prospects of nuclear powep enginerning development, the system of NPP maintenance servicing, as well as the structure of repair-productive capacities are discussed. On the basis of the analysis of the data obtained in designing the Zaporozhskaya NPP it is shown that the capital investments for organizing and mechanization of maintenance operations at the unified NPP site with four WWER-1000 reactors reach nearly 18 roubles/kW. A conclusion is drawn that at present the design of an NPP with the WWER-1000 reactor totally meets the requirements of realization of periodic maintenance operations. It is advisable to cooperate the NPP management with that of a thermal power station from the viewpoint of using manpower, which would improve the operating conditions and labour productivity of workers engaged in repair and, consequently, reduce the capital investments and repair expenditures

  2. The testing of a steam-water separating device used for vertical steam generators

    International Nuclear Information System (INIS)

    Ding Xunshen; Cui Baoyuan; Xue Yunkui; Liu Shixun

    1989-01-01

    The air-water screening tests of a steam-water separating device used for vertical steam generators at low pressure are introduced. The article puts emphasis on the qualification test of the steam-water separating device at hot conditions in a high temperature and pressure water test rig. The performance of the comprehensive test of the steam-water separating device indicates that the humidity of the steam at the drier exit is much less than the specified amount of 0.25%

  3. Steam generator in the SNR-project

    International Nuclear Information System (INIS)

    van Westenbrugge, J.K.

    1979-01-01

    The design philosophy of steam generators for 1300 MWe LMFBR's is presented. The basis for this philosophy is the present experience with the licensing of the SNR-300. This experience is reported. The approach for the steam generators for the 1300 MWe LMFBR is elaborated on, both for accident prevention and damage limitation, for the component itself as well as for the system design. Both Design Base Accident and Hypothetical Accidents are discussed. 8 refs

  4. Twin header bore welded steam generator for pressurized water reactors

    International Nuclear Information System (INIS)

    Davies, R.J.; Hirst, B.

    1979-01-01

    A description is given of a pressurized water reactor (PWR) steam generator concept, several examples of which have been in service for up to fourteen years. Details are given of the highly successful service record of this equipment and the features which have been incorporated to minimize corrosion and deposition pockets. The design employs a vertical U tube bundle carried off two horizontal headers to which the tubes are welded by the Foster Wheeler Power Products (FWPP) bore welding process. The factors to be considered in uprating the design to meet the current operating conditions for a 1000 MW unit are discussed. (author)

  5. Inverted Steam Generators for Sodium Cooled Fast Reactors

    International Nuclear Information System (INIS)

    Matal, Oldřich; Šimo, Tomáš; Matal, Oldřich Jr.

    2013-01-01

    Conclusions: Two inverted steam generators of the Czech industry provenience have still been in successful operation with no water into sodium leaks at BOR 60 (RIAR Dimitrovgrad, Russian Federation). Micromodular inverted steam generator (MMISG) since 1981 and modular inverted steam generator (MISG) since 1991. In the framework of the CP ESFR project predesign studies of 100 MW (thermal) ISG modules were performed with the consideration of MMISG and MISG design, operational and safety benefits and experience. Development of material and technology for sodium heated steam generators components reflecting contemporary domestic industrial conditions in the Czech Republic was restarted in the years 2003 to 2004 and supported in the years 2008 to 2011 by the European CP ESFR project and by the Ministry of Industry and Trade of the Czech Republic

  6. Improvements in steam cycle electric power generating plants

    International Nuclear Information System (INIS)

    Bienvenu, Claude.

    1973-01-01

    The invention relates to a steam cycle electric energy generating plants of the type comprising a fossil or nuclear fuel boiler for generating steam and a turbo alternator group, the turbine of which is fed by the boiler steam. The improvement is characterized in that use is made of a second energy generating group in which a fluid (e.g. ammoniac) undergoes a condensation cycle the heat source of said cycle being obtained through a direct or indirect heat exchange with a portion of the boiler generated steam whereby it is possible without overloading the turbo-alternator group, to accomodate any increase of the boiler power resulting from the use of another fuel while maintaining a maximum energy output. This can be applied to electric power stations [fr

  7. A Receding Horizon Controller for the Steam Generator Water Level

    International Nuclear Information System (INIS)

    Na, Man Gyun; Lee, Yoon Joon

    2003-01-01

    In this work, the receding horizon control method was used to control the water level of nuclear steam generators and applied to two linear models and also a nonlinear model of steam generators. A receding horizon control method is to solve an optimization problem for finite future steps at current time and to implement the first optimal control input as the current control input. The procedure is then repeated at each subsequent instant. The dynamics of steam generators is very different according to power levels. The receding horizon controller is designed by using a reduced linear steam generator model fixed over a certain power range and applied to a Westinghouse-type (U-tube recirculating type) nuclear steam generator. The proposed controller designed at a fixed power level shows good performance for any other power level within this power range. The steam generator shows actually nonlinear characteristics. Therefore, the proposed algorithm is implemented for a nonlinear model of the nuclear steam generator to verify its real performance and also shows good responses

  8. Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP

    Energy Technology Data Exchange (ETDEWEB)

    Kral, P. [Nuclear Research Inst. Rez (Switzerland)

    1995-12-31

    The presentation is focused on two main topics. First the applied modelling of PGV-4 steam generator for RELAP5 code are described. The results of steady-state calculation under reference conditions are compared against measured data. The problem of longitudinal subdivision of SG tubes is analysed and evaluated. Secondly, a best-estimate analysis of main steam header (MSH) rupture accident in WWER-440/213 NPP is presented. The low reliability of initiation of ESFAS signal `MSH Rupture` leads in this accident to big loss of secondary coolant, full depressurization of main steam system, extremely fast cool-down of both secondary and primary system, opening of PRZ SV-bypass valve with later liquid outflow, potential reaching of secondary criticality by failure of HPIS. 7 refs.

  9. Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP

    Energy Technology Data Exchange (ETDEWEB)

    Kral, P [Nuclear Research Inst. Rez (Switzerland)

    1996-12-31

    The presentation is focused on two main topics. First the applied modelling of PGV-4 steam generator for RELAP5 code are described. The results of steady-state calculation under reference conditions are compared against measured data. The problem of longitudinal subdivision of SG tubes is analysed and evaluated. Secondly, a best-estimate analysis of main steam header (MSH) rupture accident in WWER-440/213 NPP is presented. The low reliability of initiation of ESFAS signal `MSH Rupture` leads in this accident to big loss of secondary coolant, full depressurization of main steam system, extremely fast cool-down of both secondary and primary system, opening of PRZ SV-bypass valve with later liquid outflow, potential reaching of secondary criticality by failure of HPIS. 7 refs.

  10. Relap5/Mod3.1 analysis of main steam header rupture in VVER- 440/213 NPP

    International Nuclear Information System (INIS)

    Kral, P.

    1995-01-01

    The presentation is focused on two main topics. First the applied modelling of PGV-4 steam generator for RELAP5 code are described. The results of steady-state calculation under reference conditions are compared against measured data. The problem of longitudinal subdivision of SG tubes is analysed and evaluated. Secondly, a best-estimate analysis of main steam header (MSH) rupture accident in WWER-440/213 NPP is presented. The low reliability of initiation of ESFAS signal 'MSH Rupture' leads in this accident to big loss of secondary coolant, full depressurization of main steam system, extremely fast cool-down of both secondary and primary system, opening of PRZ SV-bypass valve with later liquid outflow, potential reaching of secondary criticality by failure of HPIS

  11. Proceedings of steam generator sludge deposition in recirculating and once through steam generator upper tube bundle and support plates

    International Nuclear Information System (INIS)

    Baker, R.L.; Harvego, E.A.

    1992-01-01

    The development of remedial measures of shot peening have given nuclear utilities viable measures to address primary water stress corrosion cracking to extend steam generator life. The nuclear utility industry is now faced with potential replacement of steam generators in nuclear power plants due to stress corrosion cracking and intergranular attach in crevice locations on the secondary side of steam generators at tube support plates and at the crevice at the top of the tube sheet. Significant work has been done on developing and understanding of the effects of sludge buildup on the corrosion process at these locations. This session was envisioned to provide a forum for the development of an understanding of the mechanisms which control the transport and deposition of sludge on the secondary side of steam generators. It is hoped that this information will aid utilities in monitoring the progression of fouling of these crevices by further knowledge in where to look for the onset of support plate crevice fouling. An understanding of the progression of fouling from upper tube support plates to those lower in the steam generator where higher temperatures cause the corrosion process to initiate first can aid the nuclear utility industry in developing remedial measures for this condition and in providing a forewarning of when to apply such remedial measures

  12. Material choices for the commercial fast reactor steam generators

    International Nuclear Information System (INIS)

    Willby, C.; Walters, J.

    1978-01-01

    Experience with fast reactor steam generators has shown them to be critical components in achieving a high availability. This paper presents the designers views on the use of ferritic materials for steam generators and describes the proposed design of the steam generators for the Commercial Fast Reactor (CFR), prototype of which are to be inserted in the Prototype Fast Reactor at Dounreay. (author)

  13. Monitoring method for steam generator operation

    International Nuclear Information System (INIS)

    Tamaoki, Tetsuo

    1991-01-01

    In an LMFBR plant having an once-through steam generator, reduction of life of a heat transfer pipe caused by heat cycle fatigue is monitored by early finding for the occurrence of abnormality in the inside of the steam generator and by continuous monitoring for the position of departure from nucleate boiling (DNB), which are difficult with existent static characteristic analysis codes. That is, RMS values of fluctuations in temperature signals sent from thermocouples for measuring the fluid temperature in the vicinity of heat transfer pipe disposed along a primary channel of the once-through type steam generator. The abnormality in heat transfer performance is monitored by the distribution change of the RMS values. Subsequently, DNB point on the side of water and steam is determined by the distribution of the RMS value. Then, accumulated values of the product between the time in which the starting point stays in the DNB region and a life consumption amount per unit time given in accordance with the operation condition are monitored. Accordingly, thermal fatigue failure of the heat transfer pipe due to temperature fluctuation in the DNB region is monitored. (I.S.)

  14. Chemical control and design considerations for CANDU-PHW steam generators

    International Nuclear Information System (INIS)

    Frost, C.R.; Churchill, B.R.

    1978-01-01

    Ontario Hydro presently operates eight nuclear power units with a total capacitiy of about 4000 MW(e) net. Operating experience has been with Monel-400 and with Inconel-600 tubed steam generators using sodium phosphate or all volatile control of the boiler steam and water system. With a heavy water Heat Transport System, steam generator tube integrity is an essential ingredient of economical power production. Only three steam generator tube failures have occurred so far in about 40 unit-years operation. None was attributable to corrosion. Factors in the good reliability are, careful engineering design, good quality control at all stages of tubing and steam generator manufacture and close chemical control. The continuing evolution of our steam generator design means that future requirements will be more stringent. (author)

  15. Steam generator deposit control program assessment at Comanche Peak

    International Nuclear Information System (INIS)

    Stevens, J.; Fellers, B.; Orbon, S.

    2002-01-01

    Comanche Peak has employed a variety of methods to assess the effectiveness of the deposit control program. These include typical methods such as an extensive visual inspection program and detailed corrosion product analysis and trending. In addition, a recently pioneered technique, low frequency eddy current profile analysis (LFEC) has been utilized. LFEC provides a visual mapping of the magnetite deposit profile of the steam generator. Analysis of the LFEC results not only provides general area deposition rates, but can also provide local deposition patterns, which is indicative of steam generator performance. Other techniques utilized include trending of steam pressure, steam generator hideout-return, and flow assisted corrosion (FAC) results. The sum of this information provides a comprehensive assessment of the deposit control program effectiveness and the condition of the steam generator. It also provides important diagnostic and predictive information relative to steam generator life management and mitigative strategies, such as special cleaning procedures. This paper discusses the techniques employed by Comanche Peak Chemistry to monitor the effectiveness of the deposit control program and describes how this information is used in strategic planning. (authors)

  16. Main trends and content of works on fabrication of fuel rods with MOX fuel for the WWER-1000 reactor

    International Nuclear Information System (INIS)

    Tsykanov, V.A.; Golovanov, V.N.; Mayorshin, A.A.; Yurchenko, A.D.; Ilyenko, S.A.; Syuzev, V.N.

    2000-01-01

    The main trends of production of pellet MOX-fuel for the WWER reactors using the trial-experimental equipment at SSC RF RIAR are set forth. The main realized parameters of fabrication of MOX-fuel pellets are presented. The content of the reactor tests program is considered with allowance for their licensing requirements for the WWER reactors. (author)

  17. Improving the refueling cycle of a WWER-1000 using cuckoo search method and thermal-neutronic coupling of PARCS v2.7, COBRA-EN and WIMSD-5B codes

    Energy Technology Data Exchange (ETDEWEB)

    Yarizadeh-Beneh, M.; Mazaheri-Beni, H.; Poursalehi, N., E-mail: n_poursalehi@sbu.ac.ir

    2016-12-15

    Highlights: • The cuckoo search algorithm is applied to the loading pattern optimization of a nuclear reactor core. • Calculations during the cycle show a good agreement between results and reference for the original LP. • Results indicate the efficient performance of cuckoo search approach coupled with thermal-neutronic solvers. • Neutronic parameters of proposed core pattern are improved relative to original core pattern. - Abstract: The fuel loading pattern optimization is an important process in the refueling design of a nuclear reactor core. Also the analysis of reactor core performance during the operation cycle can be a significant step in the core loading pattern optimization (LPO). In this work, for the first time, a new method i.e. cuckoo search algorithm (CS) has been applied to the fuel loading pattern design of Bushehr WWER-1000 core. In this regard, two objectives have been chosen for finding the best configuration including the improvement of operation cycle length associated with flattening the radial power distribution of fuel assemblies. The core pattern optimization has been performed by coupling the CS algorithm to thermal-neutronic codes including PARCS v2.7, COBRA-EN and WIMSD-5B for earning desired parameters along the operation cycle. The calculations have been done for the beginning of cycle (BOC) to the end of cycle (EOC) states. According to numerical results, the longer operation cycle for the semi-optimized loading pattern has been achieved along with less power peaking factor (PPF) in comparison to the original core pattern of Bushehr WWER-1000. Gained results confirm the efficient and suitable performance of the developed program and also the introduced CS method in the LPO of a nuclear WWER type.

  18. Experimental assessment of welded joints brittle fracture on the crack arrest criterion for WWER-1000 RPV

    International Nuclear Information System (INIS)

    Blumin, A.A.; Timofeev, B.T.

    2000-01-01

    The crack arrest fracture toughness in a vessel steel used in WWER-1000 reactor, namely in steel 15Kh2NMFA and its submerged arc welded joints, produced with Sv-08KhGNMTA, Sv-12 Kh2NMFA welding wires and NF-18 M, FZ-16 A welding fluxes, is under study. Experimental studies are carried out using three heats with the chemical composition meeting the specifications. Weld specimens 100-200 mm thick are subjected to tempering according various regimes to induce the embrittlement and simulate mechanical properties (yield strength and ductile-brittle transition temperature) corresponding to those at the end of service life under neutron radiation effect. Base metal and weld properties are compared. The wide scatter is noted for experimental data on fracture toughness temperature dependences. A possibility to use the dependence of K Ia = f (T-T k ) for determining the crack arrest fracture toughness is discussed taking in account that K Ia is a stress intensity factor calculated within the frame of static fracture mechanics [ru

  19. Corrosion aspects in steam generators of nuclear power plants

    International Nuclear Information System (INIS)

    Visoni, E.; Santos Pinto, M. dos

    1988-01-01

    Steam generators of pressurized water reactors (PWR), transfer heat from a primary coolant system to a secondary coolant system. Primary coolant water is heated in the core and passes through the steam generator that transfer heat to the secondary coolant water. However, the steam generator is dead for ionic impurities, corrosion products and fabrication/maintenence residues. These impurities concentrate between crevice and cracks. Many types of degradation mechanisms affect the tubes. The tubes are dented, craked, ovalized, wasted, etc. This paper describes the main corrosion problems in steam generators and includes the corrective actions to considered to reduce or eliminate these corrosion problems. (author) [pt

  20. PMK-2. Experimental study on steam generator behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Ezsoel, G.; Szabados, L.; Trosztel, I. [KFKI Atomic Energy Research Inst., Budabest (Hungary)

    1995-12-31

    The PMK-2 is a full pressure scaled-down model of the Paks Nuclear Power Plant, with a 1:2070 scaling ratio for the volume and power. It has a steam generator model which is a vertical section of the horizontal steam generator. The model has hot and cold collectors similarly to the steam generators of the plant. The heat transfer tubes are horizontal tubes. There are 82 rows of tubes and the elevations, as well as the heat transfer surface distribution is the same as in the plant. The elevation of the feed water supply is similar to that of the plant. To study the temperature distribution in both the primary and the secondary side several thermocouples are built in, in addition to the overall instrumentation of the loop which has again a high number of measurement channels. Paper gives a description and results of SPE-4, with special respect to the steam generator behaviour in both steady state and transient conditions. Axial distribution of coolant and feedwater temperatures are given for the primary and the secondary side of hot and cold collectors and the temperature distribution in the centre of steam generator. (orig.).

  1. PMK-2. Experimental study on steam generator behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Ezsoel, G; Szabados, L; Trosztel, I [KFKI Atomic Energy Research Inst., Budabest (Hungary)

    1996-12-31

    The PMK-2 is a full pressure scaled-down model of the Paks Nuclear Power Plant, with a 1:2070 scaling ratio for the volume and power. It has a steam generator model which is a vertical section of the horizontal steam generator. The model has hot and cold collectors similarly to the steam generators of the plant. The heat transfer tubes are horizontal tubes. There are 82 rows of tubes and the elevations, as well as the heat transfer surface distribution is the same as in the plant. The elevation of the feed water supply is similar to that of the plant. To study the temperature distribution in both the primary and the secondary side several thermocouples are built in, in addition to the overall instrumentation of the loop which has again a high number of measurement channels. Paper gives a description and results of SPE-4, with special respect to the steam generator behaviour in both steady state and transient conditions. Axial distribution of coolant and feedwater temperatures are given for the primary and the secondary side of hot and cold collectors and the temperature distribution in the centre of steam generator. (orig.).

  2. Nuclear steam generator sludge lance method and apparatus

    International Nuclear Information System (INIS)

    Shirey, R.A.; Murray, D.E.

    1991-01-01

    This paper describes a sludge lancing system for removing sludge deposits from an interior region of a steam generator. It comprises: a peripheral fluid injection means for injecting a fluid at a high pressure about a periphery of the steam generator, the peripheral fluid injection means comprising at least one elongated fluid conduit, at least one injection nozzle and a joint positioned at a predetermined point along the elongated fluid conduit for permitting the peripheral fluid injection means to bend to a predetermined angle at the joint within the steam generator; a reciprocable fluid injection means for injecting a fluid at a high pressure toward the sludge deposits and dislodging the sludge deposits; and a supporting means positioned within the interior of the steam generator for supporting the reciprocable fluid injection means throughout the reciprocation of the reciprocable fluid injection means

  3. Hydrogen-based power generation from bioethanol steam reforming

    Energy Technology Data Exchange (ETDEWEB)

    Tasnadi-Asztalos, Zs., E-mail: tazsolt@chem.ubbcluj.ro; Cormos, C. C., E-mail: cormos@chem.ubbcluj.ro; Agachi, P. S. [Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, 11 Arany Janos, Postal code: 400028, Cluj-Napoca (Romania)

    2015-12-23

    This paper is evaluating two power generation concepts based on hydrogen produced from bioethanol steam reforming at industrial scale without and with carbon capture. The power generation from bioethanol conversion is based on two important steps: hydrogen production from bioethanol catalytic steam reforming and electricity generation using a hydrogen-fuelled gas turbine. As carbon capture method to be assessed in hydrogen-based power generation from bioethanol steam reforming, the gas-liquid absorption using methyl-di-ethanol-amine (MDEA) was used. Bioethanol is a renewable energy carrier mainly produced from biomass fermentation. Steam reforming of bioethanol (SRE) provides a promising method for hydrogen and power production from renewable resources. SRE is performed at high temperatures (e.g. 800-900°C) to reduce the reforming by-products (e.g. ethane, ethene). The power generation from hydrogen was done with M701G2 gas turbine (334 MW net power output). Hydrogen was obtained through catalytic steam reforming of bioethanol without and with carbon capture. For the evaluated plant concepts the following key performance indicators were assessed: fuel consumption, gross and net power outputs, net electrical efficiency, ancillary consumptions, carbon capture rate, specific CO{sub 2} emission etc. As the results show, the power generation based on bioethanol conversion has high energy efficiency and low carbon footprint.

  4. Hydrogen-based power generation from bioethanol steam reforming

    International Nuclear Information System (INIS)

    Tasnadi-Asztalos, Zs.; Cormos, C. C.; Agachi, P. S.

    2015-01-01

    This paper is evaluating two power generation concepts based on hydrogen produced from bioethanol steam reforming at industrial scale without and with carbon capture. The power generation from bioethanol conversion is based on two important steps: hydrogen production from bioethanol catalytic steam reforming and electricity generation using a hydrogen-fuelled gas turbine. As carbon capture method to be assessed in hydrogen-based power generation from bioethanol steam reforming, the gas-liquid absorption using methyl-di-ethanol-amine (MDEA) was used. Bioethanol is a renewable energy carrier mainly produced from biomass fermentation. Steam reforming of bioethanol (SRE) provides a promising method for hydrogen and power production from renewable resources. SRE is performed at high temperatures (e.g. 800-900°C) to reduce the reforming by-products (e.g. ethane, ethene). The power generation from hydrogen was done with M701G2 gas turbine (334 MW net power output). Hydrogen was obtained through catalytic steam reforming of bioethanol without and with carbon capture. For the evaluated plant concepts the following key performance indicators were assessed: fuel consumption, gross and net power outputs, net electrical efficiency, ancillary consumptions, carbon capture rate, specific CO 2 emission etc. As the results show, the power generation based on bioethanol conversion has high energy efficiency and low carbon footprint

  5. Hydrogen-based power generation from bioethanol steam reforming

    Science.gov (United States)

    Tasnadi-Asztalos, Zs.; Cormos, C. C.; Agachi, P. S.

    2015-12-01

    This paper is evaluating two power generation concepts based on hydrogen produced from bioethanol steam reforming at industrial scale without and with carbon capture. The power generation from bioethanol conversion is based on two important steps: hydrogen production from bioethanol catalytic steam reforming and electricity generation using a hydrogen-fuelled gas turbine. As carbon capture method to be assessed in hydrogen-based power generation from bioethanol steam reforming, the gas-liquid absorption using methyl-di-ethanol-amine (MDEA) was used. Bioethanol is a renewable energy carrier mainly produced from biomass fermentation. Steam reforming of bioethanol (SRE) provides a promising method for hydrogen and power production from renewable resources. SRE is performed at high temperatures (e.g. 800-900°C) to reduce the reforming by-products (e.g. ethane, ethene). The power generation from hydrogen was done with M701G2 gas turbine (334 MW net power output). Hydrogen was obtained through catalytic steam reforming of bioethanol without and with carbon capture. For the evaluated plant concepts the following key performance indicators were assessed: fuel consumption, gross and net power outputs, net electrical efficiency, ancillary consumptions, carbon capture rate, specific CO2 emission etc. As the results show, the power generation based on bioethanol conversion has high energy efficiency and low carbon footprint.

  6. Glas generator for the steam gasification of coal with nuclear generated heat

    International Nuclear Information System (INIS)

    Buchner, G.

    1980-01-01

    The use of heat from a High Temperature Reactor (HTR) for the steam gasification of coal saves coal, which otherwise is burnt to generate the necessary reaction heat. The gas generator for this process, a horizontal pressure vessel, contains a fluidized bed of coal and steam. An ''immersion-heater'' type of heat exchanger introduces the nuclear generated heat to the process. Some special design problems of this gasifier are presented. Reference is made to the present state of development of the steam gasification process with heat from high temperature reactors. (author)

  7. Oxidation-induced embrittlement and structural changes of Zircaloy-4 tubing in steam at 700-1000 deg. C

    Energy Technology Data Exchange (ETDEWEB)

    Ali, A E; Huessein, A G; El-Sayed, A A; El Banna, O A [Atomic Energy Authority, Cairo (Egypt); El Raghy, S M [Cairo Univ. (Egypt). Faculty of Engineering

    1997-02-01

    The oxidation-induced embrittlement and structural changes of Zircaloy-4 (KWU-Type) tubing was investigated under light water reactors (LWR) Loss-of-Coolant. Accident conditions (LOCA) in temperature range 700-1000 deg. C. The effect of hydrogen addition to steam was also investigated in the temperature range 800-1000 deg. C. The oxidation-induced embrittlement was found to be a function of both temperature and time. Fractography investigation of oxidized tubing showed a typical brittle fracture in the stabilized-alpha zone. The microhardness measurements revealed that the alpha-Zr is harder than that near the mid-wall position. The oxidation-induced embrittlement at 900 deg. C was found to be higher than at 1000 deg. C. The results also indicated that the addition of 5% by volume hydrogen to steam resulted in an increase in the degree of embrittlement. (author). 22 refs, 9 figs, 3 tabs.

  8. Chemical cleaning an essential part of steam generator asset management

    International Nuclear Information System (INIS)

    Amman, Franz

    2008-01-01

    Chemical Cleaning an essential part of Steam Generator asset management accumulation of deposits is intrinsic for the operation of Steam Generators in PWRs. Such depositions often lead to reduction of thermal performance, loss of component integrity and, in some cases to power restrictions. Accordingly removal of such deposits is an essential part of the asset management of the Steam Generators in a Nuclear Power Plant. Every plant has its individual condition, history and constraints which need to be considered when planning and performing a chemical cleaning. Typical points are: - Sludge load amount and constitution of the deposits - Sludge distribution in the steam generator - Existing or expected corrosion problems - Amount and tendency of fouling for waste treatment Depending on this points the strategy for chemical cleaning shall be evolved. the range of treatment starts with very soft cleanings with a removal of approx 100 kg per steam generator and goes to a full scale cleaning which can remove up to several thousand kilograms of deposits from a steam generator. Depending on the goal to be achieved and the steam generator present an adequate cleaning method shall be selected. This requires flexible and 'customisable' cleaning methods that can be adapted to the individual needs of a plant. Such customizing of chemical cleaning methods is an essential factor for an optimized asset management of the steam generator in a nuclear power plant

  9. Steam generator materials

    International Nuclear Information System (INIS)

    Kim, Joung Soo; Han, J. H.; Kim, H. P.; Lim, Y. S.; Lee, D. H.; Suh, J. H.; Hwang, S. S.; Hur, D. H.; Kim, D. J.; Kim, Y. H.

    2002-05-01

    In order to keep the nuclear power plant(NPP)s safe and increase their operating efficiency, axial stress corrosion cracking(SCC)(IGA/IGSCC, PWSCC, PbSCC) test techniques were developed and SCC property data of the archive steam generator tubing materials having been used in nuclear power plants operating in Korea were produced. The data obtained in this study were data-based, which will be used to clarify the damage mechanisms, to operate the plants safely, and to increase the lifetime of the tubing. In addition, the basic technologies for the improvement of the SCC property of the tubing materials, for new SCC inhibition, for damaged tube repair, and for manufacturing processes of the tubing were developed. In the 1 phase of this long term research, basic SCC test data obtained from the archive steam generator tubing materials used in NPPs operating in Korea were established. These basic technologies developed in the 1 phase will be used in developing process optimization during the 2 phase in order to develop application technologies to the field nuclear power plants

  10. Nuclear steam generator tubesheet shield

    International Nuclear Information System (INIS)

    Nickerson, J.H.D.; Ruhe, A.

    1982-01-01

    The invention involves improvements to a nuclear steam generator of the type in which a plurality of U-shaped tubes are connected at opposite ends to a tubesheet and extend between inlet and outlet chambers, with the steam generator including an integral preheater zone adjacent to the downflow legs of the U-shaped tubes. The improvement is a thermal shield disposed adjacent to an upper face of the tubesheet within the preheater zone, the shield including ductile cladding material applied directly to the upper face of the tubesheet, with the downflow legs of the U-shaped tubes extending through the cladding into the tubesheet

  11. Steam and sodium leak simulation in a fluidized-bed steam generator

    International Nuclear Information System (INIS)

    Vaux, W.G.; Keeton, A.R.; Keairns, D.L.

    1977-01-01

    A fluidized-bed steam generator for the liquid metal fast breeder reactor enhances plant availability and minimizes the probability of a water/sodium reaction. An experimental test program was conceived to assess design criteria and fluidized-bed operation under conditions of water, steam, and sodium leaks. Sodium, steam, and water were leaked into helium-fluidized beds of metal and ceramic particles at 900 F. Test results show the effects of leaks on the heat transfer coefficient, quality of fluidization, leak detection, and cleanup procedures

  12. Proceedings of the twenty-first symposium of atomic energy research on WWER physics and reactor safety

    International Nuclear Information System (INIS)

    Vidovszky, I.

    2011-10-01

    The present volume contains 61 papers, presented on the twenty-first symposium of atomic energy research, held in Dresden, Germany, 19-23 September 2011. The papers are presented in their original form, i. e. no corrections or modifications were carried out. The content of this volume is divided into thematic groups: Improvement, extension and validation of parameterized few-group libraries for WWER-440 and WWER-1000.

  13. Steam generator replacement at Surry Power Station

    International Nuclear Information System (INIS)

    McKay, H.S.

    1982-01-01

    The purposes of the steam generator repair program at Surry Power Station were to repair the tube degradation caused by corrosion-related phenomena and to restore the integrity of the steam generators to a level equivalent to new equipment. The repair program consisted of (1) replacing the existing lower-shell assemblies with new ones and (2) adding new moisture separation equipment to the upper-shell assemblies. These tasks required that several pieces of reactor coolant piping, feedwater piping, main steam piping, and the steam generator be cut and refurbished for reinstallation after the new lower shell was in place. The safety implications and other potential effects of the repair program both during the repair work and after the unit was returned to power were part of the design basis of the repair program. The repair program has been completed on Unit 2 without any adverse effects on the health and safety of the general public or to the personnel engaged in the repair work. Before the Unit 1 repair program began, a review of work procedures and field changes for the Unit 2 repair was conducted. Several major changes were made to avoid recurrence of problems and to streamline procedures. Steam generator replacements was completed on June 1, 1981, and the unit is presently in the startup phase of the outrage

  14. Steam generator life management

    International Nuclear Information System (INIS)

    King, P.; McGillivray, R.; Reinhardt, W.; Millman, J.; King, B.; Schneider, W.

    2003-01-01

    'Full-Text:' Steam Generator Life Management responsibility embodies doing whatever is necessary to maintain the steam generation equipment of a nuclear plant in effective, reliable service. All comes together in that most critical deliverable, namely the submission of the documentation which wins approval for return to service after an outage program. Life management must address all aspects of SG reliability over the life of the plant. Nevertheless, the life management activities leading up to return to service approval is where all of it converges. Steam Generator Life Management activities entail four types of work, all equally important in supporting the objective of successful operation. These activities are i) engineering functions; including identification of inspection and maintenance requirements, outage planning and scope definition plus engineering assessment, design and analysis as necessary to support equipment operation, ii) fitness of service work; including the expert evaluation of degradation mechanisms, disposition of defects for return to service or not, and the fitness for service analysis as required to justify ongoing operation with acceptable defects, iii) inspection work; including large scale eddy current inspection of tubing, the definition of defect size and character, code inspections of pressure vessel integrity and visual inspections for integrity and iv) maintenance work; including repairs, retrofits, cleaning and modifications, all as necessary to implement the measures defined during activities i) through iii). The paper discusses the approach and execution of the program for the achievement of the above objectives and particularly of items i) and ii). (author)

  15. Emergency makeup of nuclear steam generators in blackout conditions

    International Nuclear Information System (INIS)

    Korolev, A.V.; Derevyanko, O.V.

    2014-01-01

    The paper describes an original solution for using steam energy to organize makeup of NPP steam generators in blackout conditions. The proposed solution combines a disk friction turbine and an axial turbine in a single housing to provide a high overall technical effect enabling the replenishment of nuclear steam generators with steam using the pump turbine drive assembly. The application of the design is analyzed and its efficiency and feasibility are shown

  16. Fifth CNS international steam generator conference

    International Nuclear Information System (INIS)

    2006-01-01

    The Fifth CNS International Steam Generator Conference was held on November 26-29, 2006 in Toronto, Ontario, Canada. In contrast with other conferences which focus on specific aspects, this conference provided a wide ranging forum on nuclear steam generator technology from life-cycle management to inspection and maintenance, functional and structural performance characteristics to design architecture. The 5th conference has adopted the theme: 'Management of Real-Life Equipment Conditions and Solutions for the Future'. This theme is appropriate at a time of transition in the industry when plants are looking to optimize the performance of existing assets, prevent costly degradation and unavailability, while looking ahead for new steam generator investments in life-extension, replacements and new-build. More than 50 technical papers were presented in sessions that gave an insight to the scope: life management strategies; fouling, cleaning and chemistry; replacement strategies and new build design; materials degradation; condition assessment/fitness for service; inspection advancements and experience; and thermal hydraulic performance

  17. Evaluation of Oconee steam-generator debris. Final report

    International Nuclear Information System (INIS)

    Rigdon, M.A.; Rubright, M.M.; Sarver, L.W.

    1981-10-01

    Pieces of debris were observed near damaged tubes at the 14th support plate elevation in the Oconee 1-B steam generator. A project was initiated to evaluate the physical and chemical nature of the debris, to identify its source, and to determine its role in tube damage at this elevation. Various laboratory techniques were used to characterize several debris and mill scale samples. Data from these samples were then compared with each other and with literature data. It was concluded that seven of eight debris samples were probably formed in the steam generator. Six of these samples were probably formed by high temperature aqueous corrosion early in the life of the steam generator. The seventh sample was probably formed by the deposition and spalling of magnetite on the Inconel steam generator tubes. None of the debris samples resembled any of the mill scale samples

  18. Steam generators under construction for the SNR-300 power plant

    Energy Technology Data Exchange (ETDEWEB)

    Essebaggers, J

    1975-07-01

    The prototype straight tube and the helical coil-steam generator has been designed and fabricated of which the straight tube steam generator has been successfully tested for over 3000 hours at prototypical conditions and is presently being dismantled for detailed examination of critical designed features. The prototype helical coil steam generator is presently under testing in the 50 MWt test facility at TNO-Hengelo with approximately 500 hours of operation at full load conditions. In an earlier presentation the design and fabrication of the prototype steam generators have been presented, while for this presentation the production units for SNR-300 will be discussed. Some preliminary information will be presented at this meeting of the dismantling operations of the prototype straight tube steam generator. (author)

  19. Steam generators under construction for the SNR-300 power plant

    International Nuclear Information System (INIS)

    Essebaggers, J.

    1975-01-01

    The prototype straight tube and the helical coil-steam generator has been designed and fabricated of which the straight tube steam generator has been successfully tested for over 3000 hours at prototypical conditions and is presently being dismantled for detailed examination of critical designed features. The prototype helical coil steam generator is presently under testing in the 50 MWt test facility at TNO-Hengelo with approximately 500 hours of operation at full load conditions. In an earlier presentation the design and fabrication of the prototype steam generators have been presented, while for this presentation the production units for SNR-300 will be discussed. Some preliminary information will be presented at this meeting of the dismantling operations of the prototype straight tube steam generator. (author)

  20. Control system for fluid heated steam generator

    Science.gov (United States)

    Boland, J.F.; Koenig, J.F.

    1984-05-29

    A control system for controlling the location of the nucleate-boiling region in a fluid heated steam generator comprises means for measuring the temperature gradient (change in temperature per unit length) of the heating fluid along the steam generator; means for determining a control variable in accordance with a predetermined function of temperature gradients and for generating a control signal in response thereto; and means for adjusting the feedwater flow rate in accordance with the control signal.

  1. Steam generator secondary pH during a steam generator tube rupture

    International Nuclear Information System (INIS)

    Adams, J.P.; Peterson, E.S.

    1991-12-01

    The Nuclear Regulatory Commission requires utilizes to determine the response of a pressurized water reactor to a steam generator tube rupture (SGTR) as part of the safety analysis for the plant. The SGTR analysis includes assumptions regarding the partitioning of iodine between liquid and vapor in steam generator secondary. Experimental studies have determined that the partitioning of iodine in water is very sensitive to the pH. Based on this experimental evidence, the NRC requested the INEL to perform an analytical assessment of secondary coolant system (SCS) pH during an SGTR. Design basis thermal and hydraulic calculations were used together with industry standard chemistry guidelines to determine the SCS chemical concentrations during an SGTR. These were used as input to the Facility for Analysis of Chemical Thermodynamics computer system to calculate the equilibrium pH in the SCS at various discrete time during an SGTR. The results of this analysis indicate that the SCS pH decreases from the initial value of 8.8 to approximately 6.5 by the end of the transient, independent of PWR design

  2. Report of the review of the safety improvement programme for South Ukraine NPP units 1 and 2 and to identify the safety issues of ''small series'' WWER-1000 NPPs. South Ukraine Yuzhnoukrainsk, Nikolaev Region Ukraine, 8 to 19 July 1996. Draft

    International Nuclear Information System (INIS)

    Bastin, S.; Hoehn, J.; Lin, C.; Taylor, R.; Benitez, F.; Dale, H.; Mueller, B.; Rieg, C.Y.

    1996-10-01

    According to the Ukrainian request the purpose of the IAEA experts' mission was to review the safety improvement programme for South Ukraine NPP Units 1 and 2 in order to advise on the completeness and adequacy of safety improvements implemented and/or proposed. Another purpose of the mission was to identify major design and operational deficiencies as a basis to compile a consolidated list of generic safety issues for the units of the 'small series'' of WWER-1000 reactors (''Issue Book for ''small series'' WWER-1000 NPPs). Conclusions and recommendations from the IAEA mission are based on the combined expertise of the international group of experts who composed the team. They are intended to assist national authorities and plant operators who have the sole responsibilities for the regulation and safe operation. tabs

  3. Steam generator replacement: a story of continuous improvement

    International Nuclear Information System (INIS)

    Sills, M.S.; Wilkerson, R.

    2009-01-01

    This paper provides a review of the history of steam generator replacement in the US focusing on the last five years. From the early replacements in the 1980s, there have been major technology improvements resulting in dramatically shorter outages and reduced radiological exposure for workers. Even though the changes for the last five years have been less dramatic, the improvement trend continues. No two steam generator replacement (SGR) projects are the same and there are some major differences including; the access path for the components to containment (is a construction opening in containment required), type of containment, number of steam generators, one piece or two piece replacement, plant type (Westinghouse, CE or B and W) and plant layout. These differences along with other variables such as delays due to plant operations and other activities not related to the steam generator replacement make analysis of performance data difficult. However, trends in outage performance and owner expectations can be identified. How far this trend will go is also discussed. Along with the trend of improved performance, there is also a significant variation in performance. Some of the contributors to this variation are identified. This paper addresses what is required for a successful outage, meeting the increasing expectations and setting new records. The authors will discuss various factors that contribute to the success of a steam generator replacement. These factors include technical issues and, equally important, organizational interface and the role the customer plays. Recommendations are provided for planning a successful steam generator replacement outage. (author)

  4. Nuclear steam generator tube to tubesheet joint optimization

    International Nuclear Information System (INIS)

    McGregor, Rod

    1999-01-01

    Industry-wide problems with Stress Corrosion Cracking in the Nuclear Steam Generator tube-to-tubesheet joint have led to costly repairs, plugging, and replacement of entire vessels. To improve corrosion resistance, new and replacement Steam Generator developments typically employ the hydraulic tube expansion process (full depth) to minimize tensile residual stresses and cold work at the critical transition zone between the expanded and unexpanded tube. These variables have undergone detailed study using specialized X-ray diffraction and analytical techniques. Responding to increased demands from Nuclear Steam Generator operators and manufacturers to credit the leak-tightness and strength contributions of the hydraulic expansion, various experimental tasks with complimentary analytical modelling were applied to improve understanding and control of tube to hole contact pressure. With careful consideration to residual stress impact, design for strength/leak tightness optimization addresses: Experimentally determined minimum contact pressure levels necessary to preclude incipient leakage into the tube/hole interface. The degradation of contact pressure at surrounding expansions caused by the sequential expansion process. The transient and permanent contact pressure variation associated with tubesheet hole dilation during Steam Generator operation. An experimental/analytical simulation has been developed to reproduce cyclic Steam Generator operating strains on the tubesheet and expanded joint. Leak tightness and pullout tests were performed during and following simulated Steam Generator operating transients. The overall development has provided a comprehensive understanding of the fabrication and in-service mechanics of hydraulically expanded joints. Based on this, the hydraulic expansion process can be optimized with respect to critical residual stress/cold work and the strength/leakage barrier criteria. (author)

  5. Researches of WWER fuel rods behaviour under RIA accident conditions

    International Nuclear Information System (INIS)

    Nechaeva, O.; Medvedev, A.; Novikov, V.; Salatov, A.

    2003-01-01

    Unirradiated fuel rod and refabricated fuel rod tests in the BIGR as well as acceptance criteria proving absence of fragmentation and the settlement modeling of refabricated fuel rods thermomechanical behavior in the BIGR-tests using RAPTA-5 code are discussed in this paper. The behaviour of WWER type simulators with E110 and E635 cladding was researched at the BIGR reactor under power pulse conditions simulating reactivity initiated accident. The results of the tests in four variants of experimental conditions are submitted. The behaviour of 12 WWER type refabricated fuel rods was researched in the BIGR reactor under power pulse conditions simulating reactivity initiated accident: burnup 48 and 60 MWd/kgU, pulse width 3 ms, peak fuel enthalpy 115-190 cal/g. The program of future tests in the research reactor MIR with high burnup fuel rod (up to 70 MWd/kgU) under conditions simulating design RIA in WWER-1000 is presented

  6. Stress corrosion cracking susceptibility of steam generator tubing on secondary side in restricted flow areas

    International Nuclear Information System (INIS)

    Fulger, M.; Lucan, D.; Radulescu, M.; Velciu, L.

    2003-01-01

    Nuclear steam generator tubes operate in high temperature water and on the secondary side in restricted flow areas many nonvolatile impurities accidentally introduced into circuit tend to concentrate. The concentration process leads to the formation of highly aggressive alkaline or acid solutions in crevices, and these solutions can cause stress corrosion cracking (SCC) on stressed tube materials. Even though alloy 800 has shown to be highly resistant to general corrosion in high temperature water, it has been found that the steam generator tubes may crack during service from the primary and/or secondary side. Stress corrosion cracking is still a serious problem occurring on outside tubes in operating steam generators. The purpose of this study was to evaluate the environmental factors affecting the stress corrosion cracking of steam generators tubing. The main test method was the exposure for 1000 hours into static autoclaves of plastically stressed C-rings of Incoloy 800 in caustic solutions (10% NaOH) and acidic chloride solutions because such environments may sometimes form accidentally in crevices on secondary side of tubes. Because the kinetics of corrosion of metals is indicated by anodic polarization curves, in this study, some stressed specimens were anodically polarized in caustic solutions in electrochemical cell, and other in chloride acidic solutions. The results presented as micrographs, potentiokinetic curves, and electrochemical parameters have been compared to establish the SCC behavior of Incoloy 800 in such concentrated environments. (authors)

  7. Modeling of coherent heat and mass-exchange phenomena for a specter of primary circuit leaks in a NPP with WWER-1000 type reactor

    International Nuclear Information System (INIS)

    Stanev, I.; Mladenova, S.; Hadjiev, V.

    2004-01-01

    Subject of study are the inter-relations between the primary leak parameters, the containment pressure and the functioning of the WWER-1000/V320 plant systems. The model includes systems for normal operation and safety systems, which are actuated in the initial stage of the accident. The studied specter of primary leaks includes diameters from 10 to 60 mm. The model is based on the design features of unit 5 in NPP Kozloduy. This paper presents a fragment of the work, performed jointly by Atoma Consult Ltd and NPP Kozloduy Plc on the validation of the symptom oriented emergency operation procedures for units 5 and 6 in NPP Kozloduy. (authors)

  8. Advanced life-cycle management for an increased steam generator performance

    International Nuclear Information System (INIS)

    Beck, J.; Schwarz, T.; Bouecke, R.; Schneider, V.

    2006-01-01

    High steam generators performance is a prerequisite for high plant availability and possible life time extension. During operation, the performance is reduced by fouling of the heating tubes and by corrosion, resulting on a reduction of the heat-exchange area. Such steam generator degradation problems arise from mechanical degradation and a continuous ingress of non-volatile contaminants, i.e. corrosion products and salt impurities accumulated in the steam generators. In addition, the tube scales in general affect the steam generator thermal performance, which ultimately cause a reduction of power output. AREVA applied an integrated service for utilities to evaluate all operational parameters influencing the steam generator performance. The evaluation is assisted by a systematic approach to evaluate the major steam generator operational data. The different data are structured and indexed in a Cleanling-Matrix. The result of this matrix is a quantified, dimensionless figure, given as the Fouling Index. The Fouling Index allows to monitor the condition of steam generators, compare it to other plants and, in combination with a life-time management applied at several German utilities, it allows verified statements on the past operation. Based on these data, an extrapolation of the potential additional life-time of the component is possible. As such, the Fouling Index is a valuable tool concerning life-time extension considerations. The application of the cleanliness criteria in combination with operational data with respect to life-time monitoring and improvements of steam generator performance are presented. (author)

  9. Steam Generator Group Project. Annual report, 1982

    International Nuclear Information System (INIS)

    Clark, R.A.; Lewis, M.

    1984-02-01

    The Steam Generator Group Project (SGGP) is an NRC program joined by additional sponsors. The SGGP utilizes a steam generator removed from service at a nuclear plant (Surry 2) as a vehicle for research on a variety of safety and reliability issues. This report is an annual summary of progress of the program for 1982. Information is presented on the Steam Generator Examination Facility (SGEF), especially designed and constructed for this research. Loading of the generator into the SGEF is then discussed. The report then presents radiological field mapping results and personnel exposure monitoring. This is followed by information on field reduction achieved by channel head decontaminations. The report then presents results of a secondary side examination through shell penetrations placed prior to transport, confirming no change in generator condition due to transport. Decontamination of the channel head is discussed followed by plans for eddy current testing and removal of the plugs placed during service. Results of a preliminary profilometry examination are then provided

  10. Functional performance of the helical coil steam generator, Consolidated Nuclear Steam Generator (CNSG) IV system. Executive summary report

    International Nuclear Information System (INIS)

    Watson, G.B.

    1975-10-01

    The objective of this project was to study the functional performance of the CNSG - IV helical steam generator to demonstrate that the generator meets steady-state and transient thermal-hydraulic performance specifications and that secondary flow instability will not be a problem. Economic success of the CNSG concepts depends to a great extent on minimizing the size of the steam generator and the reactor vessel for ship installation. Also, for marine application the system must meet stringent specifications for operating stability, transient response, and control. The full-size two-tube experimental unit differed from the CNSG only in the number of tubes and the mode of primary flow. In general, the functional performance test demonstrated that the helical steam generator concept will exceed the specified superheat of 35F at 100% load. The experimental measured superheat at comparable operating conditions was 95F. Testing also revealed that available computer codes accurately predict trends and overall performance characteristics

  11. Mushrooms as Efficient Solar Steam-Generation Devices.

    Science.gov (United States)

    Xu, Ning; Hu, Xiaozhen; Xu, Weichao; Li, Xiuqiang; Zhou, Lin; Zhu, Shining; Zhu, Jia

    2017-07-01

    Solar steam generation is emerging as a promising technology, for its potential in harvesting solar energy for various applications such as desalination and sterilization. Recent studies have reported a variety of artificial structures that are designed and fabricated to improve energy conversion efficiencies by enhancing solar absorption, heat localization, water supply, and vapor transportation. Mushrooms, as a kind of living organism, are surprisingly found to be efficient solar steam-generation devices for the first time. Natural and carbonized mushrooms can achieve ≈62% and ≈78% conversion efficiencies under 1 sun illumination, respectively. It is found that this capability of high solar steam generation is attributed to the unique natural structure of mushroom, umbrella-shaped black pileus, porous context, and fibrous stipe with a small cross section. These features not only provide efficient light absorption, water supply, and vapor escape, but also suppress three components of heat losses at the same time. These findings not only reveal the hidden talent of mushrooms as low-cost materials for solar steam generation, but also provide inspiration for the future development of high-performance solar thermal conversion devices. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. A study on improving the performance of steam generator using thermal analysis

    International Nuclear Information System (INIS)

    Li, Zhen Zhe; Heo, Kwang Su; Choi, Jun Hoo; Seol, Seoung Yun

    2008-01-01

    Steam generation mechanism is the key technology of domestic steam cleaner. Not only weight and price of steam cleaner but also the performance of steam generation mechanism must be considered to improve the competitive power of the products. In order to find out the mechanism which can be used to improve the performance of steam generator, the process of steam generation was studied at first. In the following step, possibility of control, safety of mechanism and etc were compared about the two candidated steam generation mechanism. Finally, the merit and drawback of each mechanism were summarized

  13. Status of steam generator tubing integrity at Jaslovske Bohunice NPP

    International Nuclear Information System (INIS)

    Cepcek, S.

    1997-01-01

    Steam generator represents one of the most important component of nuclear power plants. Especially, loss of tubing integrity of steam generators can lead to the primary coolant leak to secondary circuit and in worse cases to the unit shut down or to the PTS events occurrence. Therefore, to ensure the steam generator tubing integrity and the current knowledge about tube degradation propagation and development is of the highest importance. In this paper the present status of steam generator tubing integrity in operated NPP in Slovak Republic is presented

  14. Steam generator assessment for sustainable power plant operation

    International Nuclear Information System (INIS)

    Drexler, Andreas; Fandrich, Joerg; Ramminger, Ute; Montaner-Garcia, Violeta

    2012-09-01

    Water and steam serve in the water-steam cycle as the energy transport and work media. These fluids shall not affect, through corrosion processes on the construction materials and their consequences, undisturbed plant operation. The main objectives of the steam water cycle chemistry consequently are: - The metal release rates of the structural materials shall be minimal - The probability of selective / localized forms of corrosion shall be minimal. - The deposition of corrosion products on heat transfer surfaces shall be minimized. - The formation of aggressive media, particularly local aggressive environments under deposits, shall be avoided. These objectives are especially important for the steam generators (SGs) because their condition is a key factor for plant performance, high plant availability, life time extension and is important to NPP safety. The major opponent to that is corrosion and fouling of the heating tubes. Effective ways of counteracting all degradation problems and thus of improving the SG performance are to keep SGs in clean conditions or if necessary to plan cleaning measures such as mechanical tube sheet lancing or chemical cleaning. Based on more than 40 years of experience in steam-water cycle water chemistry treatment AREVA developed an overall methodology assessing the steam generator cleanliness condition by evaluating all available operational and inspection data together. In order to gain a complete picture all relevant water chemistry data (e.g. corrosion product mass balances, impurity ingress), inspection data (e.g. visual inspections and tube sheet lancing results) and thermal performance data (e.g. heat transfer calculations) are evaluated, structured and indexed using the AREVA Fouling Index Tool Box. This Fouling Index Tool Box is more than a database or statistical approach for assessment of plant chemistry data. Furthermore the AREVA's approach combines manufacturer's experience with plant data and operates with an

  15. Steam generator materials performance in high temperature gas-cooled reactors

    International Nuclear Information System (INIS)

    Chafey, J.E.; Roberts, D.I.

    1980-11-01

    This paper reviews the materials technology aspects of steam generators for HTGRs which feature a graphite-moderated, uranium-thorium, all-ceramic core and utilizes high-pressure helium as the primary coolant. The steam generators are exposed to gas-side temperatures approaching 760 0 C and produce superheated steam at 538 0 C and 16.5 MPa (2400 psi). The prototype Peach Bottom I 40-MW(e) HTGR was operated for 1349 EFPD over 7 years. Examination after decommissioning of the U-tube steam generators and other components showed the steam generators to be in very satisfactory condition. The 330-MW(e) Fort St. Vrain HTGR, now in the final stages of startup, has achieved 70% power and generated more than 1.5 x 10 6 MWh of electricity. The steam generators in this reactor are once-through units of helical configuration, requiring a number of new materials factors including creep-fatigue and water chemistry control. Current designs of larger HTGRs also feature steam generators of helical once-through design. Materials issues that are important in these designs include detailed consideration of time-dependent behavior of both base metals and welds, as required by current American Society of Mechanical Engineers (ASME) Code rules, evaluation of bimetallic weld behavior, evaluation of the properties of large forgings, etc

  16. New steam generators slated for nuclear units

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This article is a brief discussion of Duke Power's plans to replace steam generators at its McGuire and Catawba nuclear units. A letter of intent to purchase (from Babcock and Wilcox) the 12 Westinghouse steam generators has been signed, but no constructor has been selected at this time. This action is brought about by the failures of more than 3000 tubes in these units

  17. Soviet steam generator technology: fossil fuel and nuclear power plants

    International Nuclear Information System (INIS)

    Rosengaus, J.

    1987-01-01

    In the Soviet Union, particular operational requirements, coupled with a centralized planning system adopted in the 1920s, have led to a current technology which differs in significant ways from its counterparts elsewhere in the would and particularly in the United States. However, the monograph has a broader value in that it traces the development of steam generators in response to the industrial requirements of a major nation dealing with the global energy situation. Specifically, it shows how Soviet steam generator technology evolved as a result of changing industrial requirements, fuel availability, and national fuel utilization policy. The monograph begins with a brief technical introduction focusing on steam-turbine power plants, and includes a discussion of the Soviet Union's regional power supply (GRES) networks and heat and power plant (TETs) systems. TETs may be described as large central co-generating stations which, in addition to electricity, provide heat in the form of steam and hot water. Plants of this type are a common feature of the USSR today. The adoption of these cogeneration units as a matter of national policy has had a central influence on Soviet steam generator technology which can be traced throughout the monograph. The six chapters contain: a short history of steam generators in the USSR; steam generator design and manufacture in the USSR; boiler and furnace assemblies for fossil fuel-fired power stations; auxiliary components; steam generators in nuclear power plants; and the current status of the Soviet steam generator industry. Chapters have been abstracted separately. A glossary is included containing abbreviations and acronyms of USSR organizations. 26 references

  18. Impact of a 1,000-foot thermal mixing zone on the steam electric power industry

    International Nuclear Information System (INIS)

    Veil, J.A.

    1994-04-01

    Thermal discharge requirements for power plants using once-through cooling systems are based on state water quality standards for temperatures that must be met outside of designated mixing zones. This study evaluates the impact of limiting the extent of thermal mixing zones. This study evaluates the impact of limiting the extent of thermal mixing zones to no more than 1,000 feet from the discharge point. Data were collected from 79 steam electric plants. Of the plants currently using once-through cooling systems, 74% could not meet current thermal standards at the edge of a 1,000-foot mixing zone. Of this total, 68% would retrofit cooling towers, and 6% would retrofit diffusers. The estimated nationwide capital cost for retrofitting plants that could not meet current thermal standards at the edge of a 1,000-foot mixing zone is $21.4 billion. Conversion of a plant from once-through cooling to cooling towers or addition of diffusers would result in a lower energy output from that plant. For the affected plants, the total estimated replacement cost would be $370 to $590 million per year. Some power companies would have to construct new generating capacity to meet the increased energy demand. The estimated nationwide cost of this additional capacity would be $1.2 to $4.8 billion. In addition to the direct costs associated with compliance with a 1,000-foot mixing zone limit, other secondary environmental impacts would also occur. Generation of the additional power needed would increase carbon dioxide emissions by an estimated 8.3 million tons per year. In addition, conversion from once-through cooling systems to cooling towers at affected plants would result in increased evaporation of about 2.7 million gallons of water per minute nationwide

  19. Primary separator replacement for Bruce Unit 8 steam generators

    International Nuclear Information System (INIS)

    Roy, S.B.; Mewdell, C.G.; Schneider, W.G.

    2000-01-01

    During a scheduled maintenance outage of Bruce Unit 8 in 1998, it was discovered that the majority of the original primary steam separators were damaged in two steam generators. The Bruce B steam generators are equipped with GXP type primary cyclone separators of B and W supply. There were localized perforations in the upper part of the separators and large areas of generalized wall thinning. The degradation was indicative of a flow related erosion corrosion mechanism. Although the unit- restart was justified, it was obvious that corrective actions would be necessary because of the number of separators affected and the extent of the degradation. Repair was not considered to be a practical option and it was decided to replace the separators, as required, in Unit 8 steam generators during an advanced scheduled outage. GXP separators were selected for replacement to minimize the impact on steam generator operating characteristics and analysis. The material of construction was upgraded from the original carbon steel to stainless steel to maximize the assurance of full life. The replacement of the separators was a first of a kind operation not only for Ontario Power Generation and B and W but also for all CANDU plants. The paper describes the degradations observed and the assessments, the operating experience, manufacture and installation of the replacement separators. During routine inspection in 1998, many of the primary steam separators in two of steam generators at Bruce Nuclear Division B Unit 8 were observed to have through wall perforations. This paper describes assessment of this condition. It also discusses the manufacture and testing of replacement primary steam separators and the development and execution of the replacement separator installation program. (author)

  20. Chemical cleaning of nuclear (PWR) steam generators

    International Nuclear Information System (INIS)

    Welty, C.S. Jr.; Mundis, J.A.

    1982-01-01

    This paper reports on a significant research program sponsored by a group of utilities (the Steam Generator Owners Group), which was undertaken to develop a process to chemically remove corrosion product deposits from the secondary side of pressurized water reactor (PWR) power plant steam generators. Results of this work have defined a process (solvent system and application methods) that is capable of removing sludge and tube-to-tube support plate crevice corrosion products generated during operation with all-volatile treatment (AVT) water chemistry. Considers a plant-specific test program that includes all materials in the steam generator to be cleaned and accounts for the physical locations (proximity and contact) of those materials. Points out that prior to applying the process in an operational unit, the utility, with the participation of the NSSR vendor, must define allowable total corrosion to the materials of construction of the unit