WorldWideScience

Sample records for wires tapes coated

  1. How PE tape performs under concrete coating

    International Nuclear Information System (INIS)

    Dritt, H.J.

    1984-01-01

    The program objectives were to evaluate the performance of polyethylene tape plant coating and fusion bonded epoxy powder systems with particular respect to the following: 1. Concrete coating application procedures; 2. The shear resistance during laying and retrieving operations of the coating at the various interfaces (a) Pipe and anti-corrosion coating; (b) Anti-corrosion coating and outerwrap; (c) Overlap areas of the anti-corrosion and outerwrap layers; (d) Between concrete and the various corrosion coatings during laying and retrieving operations. 3. Resistance to damage of the coating as a consequence of cracking or slippage of the concrete weight coating. 4. Ability of various coatings to withstand the damage during concrete application by both impact and compression methods; 5. Evaluation of tape and shrink sleeve joint coatings at the cut-back area as well as performance of tape under hot asphalt coating

  2. Pin Wire Coating Trip Report

    International Nuclear Information System (INIS)

    Spellman, G P

    2004-01-01

    A meeting to discuss the current pin wire coating problems was held at the Reynolds plant in Los Angeles on 2MAR04. The attendance list for Reynolds personnel is attached. there was an initial presentation which gave a brief history and the current status of pin wire coating at Reynolds. There was a presentation by Lori Primus on the requirements and issues for the coating. There was a presentation by Jim Smith of LANL on the chemistry and to some extent process development done to date. There was a long session covering what steps should be taken in the short term and, to a lesser extent, the long term. The coating currently being used is a blend of two polymers, polyethersulfone and polyparabanic acid (PPA) and some TiO2 filler. This system was accepted and put into production when the pin wire coating was outsourced to another company in 1974. When that company no longer was interested, the wire coating was brought in-house to Reynolds. At that time polyparabanic acid was actually a commercial product available from Exxon under the trade name Tradlon. However, it appears that the material used at Reynolds was synthesized locally. Also, it appears that a single large batch was synthesized in that time period and used up to 1997 when the supply ran out. The reason for the inclusion of TiO2 is not known although it does act as a rheological thickener. However, a more controlled thickening can be obtained with materials such as fumed silica. This material would have less likelihood of causing point imperfections in the coatings. Also, the mixing technique being used for all stages of the process is a relatively low shear ball mill process and the author recommends a high shear process such as a three roll paint mill, at least for the final mixing. Since solvent is added to the powder at Reynolds, it may be that they need to have the paint mill there

  3. Electromechanical characterization of superconducting wires and tapes at 77 K

    CERN Document Server

    Bjoerstad, Roger

    The strain dependency of the critical current in state-of-the-art cuprate high-temperature superconductors (HTS) has been characterized. A universal test machine (UTM) combined with a critical current measurement system has been used to characterize the mechanical and the superconducting properties of conductors immersed in an open liquid nitrogen dewar. A set-up has been developed in order to perform simultaneous measurements of the superconductor lattice parameter changes, critical current, as well as the stress and strain at 77 K in self-field in a high energy synchrotron beamline. The HTS tapes and wires studied were based on YBCO, Bi-2223 and Bi-2212. The YBCO tapes were produced by SuperPower and American Superconductors (AMSC). Two types of Bi-2223 tapes, HT and G, were produced by Sumitomo Electric Industries (SEI). The Bi-2212 wires were produced by Oxford Superconducting Technology (OST) using Nexans granulate precursor, before undergoing a specialized over pressure (OP) processing and heat treatmen...

  4. Elongated grains in cube textured nickel substrate tapes and flat wires

    International Nuclear Information System (INIS)

    Eickemeyer, J; Gueth, A; Holzapfel, B

    2008-01-01

    Cube textured nickel substrate tapes and flat wires with an increased grain aspect ratio were prepared from nickel micro-alloyed with silver plus yttrium and silver, respectively. Whereas the maximum grain aspect ratio for the tapes was about 6, this value reached up to 14 for the flat wires

  5. A jelly-roll process for high temperature superconducting tapes and wires

    International Nuclear Information System (INIS)

    Tsuei, C.C.; Chi, C.C.; Frey, T.; Mitzi, D.B.; Kazyaka, T.; Haugan, T.; Ye, J.; Patel, S.; Shaw, D.T.; Wu, M.K.

    1992-01-01

    As an alternative to the powder-in-tube method, a new technique called the jelly-roll process is proposed for making high-T c superconducting tapes and wires. A normal-metal sheet coated with high-T c cuprate is configured in a jelly-roll fashion and cold worked into tapes or wires made of alternating cuprate superconductor and normal metal layers. The feasibility of this new process is demonstrated for both the YBa 2 Cu 3 O 7 /Ag and Bi 2 Sr 2 CaCu 2 O 8 /Ag composite systems. The role of reduction in the cross-sectional area by cold-rolling, heat treatment and oxygenation in optimizing T c and J c has been studied. Preliminary results indicate that partialmelt texturing, in the Bi 2 Sr 2 CaCu 2 O 8 /Ag system, results in a relatively field independent J c (H c (H = 0) ∝5 X 10 4 A cm -2 at 4.2 K

  6. A jelly-roll process for high temperature superconducting tapes and wires

    Energy Technology Data Exchange (ETDEWEB)

    Tsuei, C C; Chi, C C; Frey, T; Mitzi, D B; Kazyaka, T [IBM Thomas J. Watson Research Center, Yorktown Heights, NY (United States); Haugan, T; Ye, J; Patel, S; Shaw, D T [New York State Inst. on Superconductivity, SUNY, Buffalo, Amherst, NY (United States); Wu, M K [Dept. of Physics, National Tsing Hua Univ., Hsinchu (Taiwan)

    1992-07-01

    As an alternative to the powder-in-tube method, a new technique called the jelly-roll process is proposed for making high-T[sub c] superconducting tapes and wires. A normal-metal sheet coated with high-T[sub c] cuprate is configured in a jelly-roll fashion and cold worked into tapes or wires made of alternating cuprate superconductor and normal metal layers. The feasibility of this new process is demonstrated for both the YBa[sub 2]Cu[sub 3]O[sub 7]/Ag and Bi[sub 2]Sr[sub 2]CaCu[sub 2]O[sub 8]/Ag composite systems. The role of reduction in the cross-sectional area by cold-rolling, heat treatment and oxygenation in optimizing T[sub c] and J[sub c] has been studied. Preliminary results indicate that partialmelt texturing, in the Bi[sub 2]Sr[sub 2]CaCu[sub 2]O[sub 8]/Ag system, results in a relatively field independent J[sub c] (H< or approx.7T) with J[sub c](H = 0) [proportional to]5 X 10[sup 4] A cm[sup -2] at 4.2 K.

  7. First steps towards cube textured nickel profile wires for YBCO-coated conductors

    International Nuclear Information System (INIS)

    Eickemeyer, J.; Gueth, A.; Freudenberger, J.; Holzapfel, B.; Schultz, L.

    2011-01-01

    The cube texture as a typical sheet texture can also be formed by cold drawing and recrystallization in profile wires. Cube textured Ni profile wires containing up to 96.2% cube oriented grains in the central region were obtained. Forthcoming investigations are promising to get a textured substrate wire for YBCO-coated conductors. Cube textured nickel alloy tapes prepared by cold rolling and annealing (RABiTS method) represent a standard metallic substrate for superconductor coatings of the YBa 2 Cu 3 O 7-δ (YBCO) type. These tapes have a width to thickness ratio of about 30-100. However, a value of close to one is optimal concerning low energetic losses under alternating current applications. First experiments on micro-alloyed nickel prove that the cube texture as a typical sheet texture can also be formed in profile wires with a rectangular cross-section after cold drawing and recrystallization treatment.

  8. Numerical Simulation of Wire-Coating

    DEFF Research Database (Denmark)

    Wapperom, Peter; Hassager, Ole

    1999-01-01

    A finite element program has been used to analyze the wire-coating process of an MDPE melt. The melt is modeled by a nonisothermal Carreau model. The emphasis is on predicting an accurate temperature field. Therefore, it is necessary to include the heat conduction in the metal parts. A comparison...

  9. Development of Powder-in-Tube Processed Iron Pnictide Wires and Tapes

    KAUST Repository

    Ma, Yanwei

    2011-06-01

    The development of PIT fabrication process of iron pnictide superconducting wires and tapes has been reviewed. Silver was found to be the best sheath material, since no reaction layer was observed between the silver sheath and the superconducting core. The grain connectivity of iron pnictide wires and tapes has been markedly improved by employing Ag or Pb as dopants. At present, critical current densities in excess of 3750 A /cm 2 (I c = 37.5 A) at 4.2 K have been achieved in Ag-sheathed SrKFeAs wires prepared with the above techniques, which is the highest value obtained in iron-based wires and tapes so far. Moreover, Ag-sheathed Sm-1111 superconducting tapes were successfully prepared by PIT method at temperatures as low as ̃ 900 °C, instead of commonly used temperatures of ̃ 1200 °C. These results demonstrate the feasibility of producing superconducting pnictide composite wires, even grain boundary properties require much more attention. © 2010 IEEE.

  10. Stress-strain effects on powder-in-tube MgB2 tapes and wires

    International Nuclear Information System (INIS)

    Katagiri, Kazumune; Takaya, Ryuya; Kasaba, Koichi; Tachikawa, Kyoji; Yamada, Yutaka; Shimura, Satoshi; Koshizuka, Naoki; Watanabe, Kazuo

    2005-01-01

    The effects of stress-strain on the critical current, I c , of ex situ powder-in-tube (PIT)-processed Ni-sheathed MgB 2 tapes and round wires as well as in situ PIT-processed Cu-sheathed wires at 4.2 K in a magnetic field up to 5 T have been studied. The effect of In powder addition on the Ni-sheathed MgB 2 wire was not so clear compared with that in the tape, in which the irreversible strain, ε irr , for the I c degradation onset increases significantly by the addition. This is attributed to the difference in the microstructure of the core associated with cold workings. A peak and gradual degradation behaviour of I c with strain beyond ε irr was found in the wire, whereas no evident peak and a steep degradation behaviour was found in the tape. As a possible reason, the difference in the triaxial residual stress state at 4.2 K due to the difference in geometry of the cross-section is suspected. The transverse compression tests revealed that I c of the wire did not degrade up to 270 MPa. Again, the effect of In addition was minimal. The Young's modulus of MgB 2 , 31-41 GPa, at room temperature was estimated by a tensile test of Cu sheath wire using a high-accuracy extensometer and the law of mixtures. The tensile strain dependence of I c in the Cu sheath wire was similar to that in the Ni-sheathed wire, ε irr being 0.4%. However, the stress corresponding to ε irr , 50 MPa, was about 1/10 of that for the Ni-sheath wire and the irreversible transverse compressive stress, 150 MPa, was also lower. The effect of bending strain on the I c in Cu-sheathed wire was compared with that of the tensile strain

  11. Delamination behaviour in differently copper laminated REBCO coated conductor tapes under transverse loading

    Energy Technology Data Exchange (ETDEWEB)

    Gorospe, Alking [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Department of Engineering, Aurora State College of Technology, Baler Aurora 3200 (Philippines); Nisay, Arman [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of); Shin, Hyung-Seop, E-mail: hsshin@andong.ac.kr [Department of Mechanical Design Engineering, Andong National University, 1375 Kyungdong-Ro, Andong 760-749 (Korea, Republic of)

    2014-09-15

    Highlights: • I{sub c} degradation behavior under transverse tension loading in different CC tape structure. • Weibull distribution analysis applied on delamination mechanism of CC tape. • Delamination mechanism on CC tapes depending on copper lamination type. • SEM and WDS mapping analysis of delamination sites under transverse loading. - Abstract: Laminated HTS coated conductor (CC) tapes having a unique multi-layer structure made them vulnerable when exposed to transverse loading. Electromechanical transport properties of these CC tapes can be affected by excessive transverse stresses. Due to the coefficient of thermal expansion (CTE) mismatch and incompatibility among constituent materials used in coil applications, delamination among layers occurs and causes critical current, I{sub c} degradation in the CC tapes. In this study, the delamination behaviors in copper (Cu) solder-laminated CC tapes by soldering and surround Cu-stabilized ones by electroplating under transverse tension loading were investigated. Similarly to the surround Cu-stabilized CC tapes in our previous reports, the Cu solder-laminated CC tapes also showed an abrupt and gradual I{sub c} degradation behavior. However, the Cu solder-laminated CC tapes showed different delamination morphologies as compared to the surround Cu-stabilized CC tapes; the superconducting side and the substrate side of the Cu solder laminated CC tapes were totally separated by delamination. On the other hand, the brass laminate did not show any significant effect on the delamination strength when it is added upon the surround Cu-stabilized CC tapes.

  12. AC loss characteristics of Bi2223/Ag sheathed tape wires subjected to mechanical strains and stresses

    International Nuclear Information System (INIS)

    Tsukamoto, Osami; Li, Z

    2007-01-01

    The influence of uniaxial tensile stress-strain on the AC loss characteristics of multifilamentary Bi2223/Ag sheathed tape wires was investigated. The uniaxial tensile stress-strain was applied to the sample wire in liquid nitrogen at atmospheric pressure, and the AC losses (transport, magnetization and total losses) were measured by an electric method. Two kinds of wire, oxide-dispersion strengthened Ag-alloy sheathed and Ag-alloy sheathed wires, were tested. The stress-strain curves of the tested wires were divided in three regions, i.e. elastic deformation, continuous plastic deformation and serrated-like plastic deformation regions, though the ranges of those regions were different for different kinds of wire. In the elastic and continuous plastic regions, the stress-strain curve was smooth and continuous, and in the serrated-like plastic region, the curve was rough. In the serrated-like plastic region, the wires kept elongating, while increase of the tensile stress was suspended. Dependences of the critical currents on the stress-strain were generally as follows. While decreases of the wire critical currents were in the range of less than 4% of the original values of the no-stress condition, the critical currents of the wires were reversible, that is, the critical currents recovered the original values at zero stress when the stress were released, regardless of whether the wires were in the elastic or continuous plastic region. In the continuous plastic region, the critical currents decreased up to 10%-15% of the original values and the critical currents were irreversible when the degradations of the critical currents exceeded about 4%. In the serrated-like plastic regions, the critical currents were more severely degraded. The AC loss characteristics of the wires are different in those regions. In the elastic and continuous plastic regions, the absolute values of AC losses were dependent on the stress-strain. However, the dependences of those normalized

  13. Wire winding increases lifetime of oxide coated cathodes

    Science.gov (United States)

    Kerslake, W.; Vargo, D.

    1965-01-01

    Refractory-metal heater base wound with a thin refractory metal wire increases the longevity of oxide-coated cathodes. The wire-wound unit is impregnated with the required thickness of metal oxide. This cathode is useful in magnetohydrodynamic systems and in electron tubes.

  14. Rapid characterization of superconducting wires and tapes in strong pulsed magnetic fields

    International Nuclear Information System (INIS)

    Bockstal, L. van; Keyser, A. de; Deschagt, J.; Hopkins, S.C.; Glowacki, B.A.

    2007-01-01

    A new measurement system for rapid characterization of superconducting wires and tapes is developed. The CryoPulse-BI is a system to provide a direct measurement of critical material parameters for superconducting materials when high long pulsed magnetic fields and strong currents are applied. In the experiments, synchronized magnetic fields up to 30 T and current pulses up to 5 kA are generated with adjustable timing. Varying the magnetic field strength, the current through the sample and the BI timing allows for a thorough characterization of the sample and the determination of critical currents. The rapid cycle time of the experiments yields a rapid and thorough determination of the critical parameters. The method has been tested on low T c as well as high T c materials with the field parallel or perpendicular to the current. The discussion covers the current state of the art including a comparison of our results to classical DC characterization measurements

  15. Quantitative electron microscopy and spectroscopy of MgB2 wires and tapes

    International Nuclear Information System (INIS)

    Birajdar, B; Peranio, N; Eibl, O

    2008-01-01

    In MgB 2 the correlation of microstructure with superconducting properties, in particular the critical current density, requires powerful analytical tools. Critical current densities and electrical resistivities of different MgB 2 superconductors differ by orders of magnitudes and the current limiting mechanisms have not been fully understood. Granularity of MgB 2 is one significant reason for reduced critical current densities and is introduced intrinsically by the anisotropy of B c2 but also extrinsically by the microstructure of the material. B c2 enhancement by doping is another important challenge for chemical analysis and, at present, doping levels are not well controlled on the sub-μm scale. In this paper the quantitative electron microscopy and spectroscopy methods essential for the microstructural analysis of MgB 2 are described. By quantitative electron microscopy and spectroscopy we mean a combined SEM and TEM analysis that covers various length scales from μm to nm. Contamination-free sample preparation, chemical mapping including B, and advanced chemical quantification using x-ray microanalysis were essential elements of the applied methodology. The methodology was applied to in situ and ex situ MgB 2 wires and tapes with and without SiC additives. Quantitative B analysis by EDX spectroscopy was applied quantitatively in the SEM and TEM, which is a major achievement. Although MgB 2 is a binary system, the thermodynamics of phase formation is complex, and the complexity is dramatically increased if additives like SiC are used. The small, sub-μm grain sizes of the matrix and secondary phases require TEM methods. However, granularity on the μm scale was also identified and underlines the importance of the combined SEM and TEM studies. Significant differences in the microstructure were observed for in situ and ex situ samples. This holds particularly if SiC was added and yielded Mg 2 Si for in situ samples annealed at 600-650 deg. C and Mg-Si-O phases

  16. Influence of bress laminate volume fraction on electromechanical properties of externally laminated coated conductor tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay M.; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Lee, Jae Hun; Lee, Hun Ju; Moon, Seung Hyun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-09-15

    The enhancement of mechanical properties of coated conductor (CC) tapes in practical application are usually achieved by reinforcing through lamination or electroplating metal layers on either sides of the CC tape. Mechanical or electromechanical properties of the CC tapes have been largely affected by the lamination structure under various loading modes such as tension, bending or even cyclic. In this study, the influence of brass laminate volume fraction on electromechanical properties of RCE-DR processed Gadolinium-barium-copper-oxide (GdBCO) CC tapes was investigated. The samples used were composed of single-side and both-side laminate of brass layer to the Cu-stabilized CC tape and their Ic behaviors were compared to those of the Cu-stabilized CC tape without external lamination. The stress/strain dependences of Ic in laminated CC tapes under uniaxial tension were analyzed and the irreversible stress/strain limits were determined. As a result, the increase of brass laminate volume fraction initially increased the irreversible strain limit and became gradual. The corresponding irreversible stress limit, however, showed no difference even though the brass laminate volume fraction increased to 3.4. But the irreversible load limit linearly increased with the brass laminate volume fraction.

  17. Improvements of fabrication processes and enhancement of critical current densities in (Ba,K)Fe2As2 HIP wires and tapes

    Science.gov (United States)

    Pyon, Sunseng; Suwa, Takahiro; Tamegai, Tsuyoshi; Takano, Katsutoshi; Kajitani, Hideki; Koizumi, Norikiyo; Awaji, Satoshi; Zhou, Nan; Shi, Zhixiang

    2018-05-01

    We fabricated (Ba,K)Fe2As2 superconducting wires and tapes using the powder-in-tube method and hot isostatic pressing (HIP). HIP wires and tapes showed a high value of transport critical current density (J c) exceeding 100 kAcm‑2 at T = 4.2 K and the self-field. Transport J c in the HIP wire reached 38 kAcm‑2 in a high magnetic field of 100 kOe. This value is almost twice larger than the previous highest value of J c among round wires using iron-based superconductors. Enhancement of J c in the wires and tapes was caused by improvement of the drawing process, which caused degradation of the core, formation of microcracks, weak links between grains, and random orientation of grains. Details of the effect of the improved fabrication processes on the J c are discussed.

  18. Delamination behaviour of GdBCO coated conductor tapes under transverse tension

    International Nuclear Information System (INIS)

    Gorospe, A.; Nisay, A.; Dizon, J.R.; Shin, H.S.

    2013-01-01

    Highlights: •Installation of a test frame which gives precisely aligned transverse load. •Investigation of I c degradation behaviour depending on the type of sample delamination. •Inhomogeneity of the CC tapes caused large variation on delamination strength. •SEM and EDS analysis of delamination sites under transverse loading. -- Abstract: The electromechanical property behaviour of 2G coated conductor (CC) tapes fabricated by multi-layer deposition process both in the in-plane and transverse direction should be understood. The CC tapes are used in the fabrication of epoxy resin-impregnated coils. In such case, the Lorentz force due to the high magnetic field applied as well as the thermal stress due to the difference in coefficient of thermal expansion (CTE) among constituent layers during cooling to cryogenic temperature will induce transversely applied load to the surface of CC tapes in coils. Hence, the CC tape should have a good mechanical property in the transverse direction in order to maintain its superior performance under magnetic field. In this study, a test frame which gives precisely aligned transverse load was devised. Using the fixture, the delamination behaviours including the delamination strength of the GdBCO CC tapes under transverse tensile loading were investigated. Large variation on the delamination strength of the CC tapes was recorded and might have resulted from the slit edge effect and the inhomogeneity of the CC tapes. The I c degradation behaviour under transverse load was related to the location where delamination occurred in the sample

  19. Laser fabrication nanocrystalline coatings using simultaneous powders/wire feed

    Science.gov (United States)

    Li, Jianing; Zhai, Tongguang; Zhang, Yuanbin; Shan, Feihu; Liu, Peng; Ren, Guocheng

    2016-07-01

    Laser melting deposition (LMD) fabrication is used to investigate feasibilty of simultaneously feeding TC17 wire and the Stellite 20-Si3N4-TiC-Sb mixed powders in order to increase the utilization ratio of materials and also quality of LMD composite coatings on the TA1 substrate. SEM images indicated that such LMD coating with metallurgical joint to substrate was formed free of the obvious defects. Lots of the ultrafine nanocrystals (UNs) were produced, which distributed uniformly in some coating matrix location, retarding growth of the ceramics in a certain extent; UNs were intertwined with amorphous, leading the yarn-shape materials to be produced. Compared with substrate, an improvement of wear resistance was achieved for such LMD coating.

  20. Comparison of novel ultra-high molecular weight polyethylene tape versus conventional metal wire for sublaminar segmental fixation in the treatment of adolescent idiopathic scoliosis.

    Science.gov (United States)

    Takahata, Masahiko; Ito, Manabu; Abumi, Kuniyoshi; Kotani, Yoshihisa; Sudo, Hideki; Ohshima, Shigeki; Minami, Akio

    2007-08-01

    Retrospective study. To compare the surgical outcomes of posterior translational correction and fusion using hybrid instrumentation systems with either sublaminar Nesplon tape or sublaminar metal wire to treat adolescent idiopathic scoliosis (AIS). Nesplon tape, which consists of a thread of ultra-high molecular weight polyethylene fibers, has advantages over metal wire: (1) its soft and flexible properties avoid neural damage and (2) its flat configuration avoids focal distribution of the stresses to lamina; however, the efficacy of Nesplon tape in the correction of spinal deformity is as yet, still unclear. Thirty AIS patients at a single institution underwent posterior correction and fusion using hybrid instrumentation containing hook, pedicle screw, and either sublaminar polyethylene taping (15) or sublaminar metal wiring (15). Patients were evaluated preoperatively, immediately after surgery, and at a 2-year follow-up according to the radiographic changes in curve correction, operating time, intraoperative blood loss, complications, and the Scoliosis Research Society patient questionnaire (SRS-24) score. The average correction rate was 63.0% in the Nesplon tape group and 59.9% in the metal wire group immediately after surgery (P = 0.62). Fusion was obtained in all the patients without significant correction loss in both groups. There was no significant difference in operative time, intraoperative blood loss, and postoperative SRS-24 scores between the 2 groups. Complications were superficial skin infection in a single patient in the Nesplon tape group, and transient sensory disturbance in 1 patient and temporal superior mesenteric artery syndrome in another patient in the metal wire group. The efficacy of Nesplon tape in correction of deformity is equivalent to that of metal wire, and fusion was completed without significant correction loss. The soft and flexible properties and flat configuration of Nesplon tape make this a safe application for the treatment

  1. Bi axially textured YBCO coated tape prepared using dynamic magnetic grain alignment

    International Nuclear Information System (INIS)

    Genoud, Jean-Yves; Quinton, William

    1999-01-01

    A new magnetic grain alignment technique has been applied to produce bi axially aligned YBCO coated tapes. A bi axially aligned dispersion of orthorhombic Y 2 Ba 4 Cu 7 O 15 (Y-247) powder was settled on un textured silver substrates. The Y-247 tapes were then melt processed to achieve high critical current YBa 2 Cu 3 O 7 (Y-123) tapes with CuO as a secondary phase. The biaxial alignment is preserved after the densification process and a clear enhancement of J c relative to identically prepared un textured or uniaxially textured samples is obtained. Critical current densities of up to 5000 A cm -2 at 77 K in self-field and 1500 A cm -2 in 0.5 T magnetic field at 65 K were obtained in films from 20 to 40 μm thick. Problems were experienced in achieving fully densified thick films while retaining biaxial texture. The initial grain size distribution was found to have a major influence on the final microstructure. Provided significant improvements in J c can be obtained this method offers an alternative to coated tape processes based on epitaxial growth which has the advantage that it does not require textured substrates. The biaxial alignment technique described here intrinsically acts on the bulk material rather than at surfaces. This offers the possibility of texturing without thickness limitations. (author)

  2. Optimization of superconductivity properties in MgB2 Wires and tapes to generate high magnetic fields

    International Nuclear Information System (INIS)

    Serrano, German

    2005-01-01

    We present, in this work, a study of the effects of doping, heat treatments and mechanisms of deformation, over the microstructure and superconducting properties of powder in tube (PIT) M g B 2 wires and tapes.We observed that nano-SiC doping improves the critical current density (J c ) and the upper critical field (H c 2).The combined use of doping and Hot Isostatic Pressing (HIPing), produces samples with high density and improves J c s.We studied the influence of number and temperature of intermediate heat treatments (TTI), during the fabrication of wires and tapes.We observed that TTI made at low temperature ( o C), results in wires and tapes with better microstructure than those made at high temperature.Moreover, the increment of the heat treatments numbers at high temperature, decreases the quality of microstructure and J c .In the study of sheaths materials, we observed that the J c values measured by magnetization in Ti sheath samples are two order of magnitude larger than the values measured by transport, which indicates macroscopic fracture problems.On other hand, we fabricated tapes with excellent J c values (10 4 A/cm 2 at 4K and 7T), which are similar to those of samples made with HIPing.This tape presents some degree of grains alignment, as a consequence of rolling.We observed J c anisotropy in both transport and magnetization measurements in a range between 4 and 26K, and the same effect in H c 2.The anisotropy factor in Jc increase with applied field, while the anisotropy in Hc2 is constant with temperature (H c 2 parallel H c 2 perpendicular ∼1.2).Finally, we observed that carbon nanotubes doping improves H c 2 and this effects is most important at temperatures below 5K.This increase in H c 2 was predicted by Gurevich [45], as an effect of modification in scattering coefficient between electronics bands of M g B 2 by doping [es

  3. Exploration of new superconductors and functional materials, and fabrication of superconducting tapes and wires of iron pnictides.

    Science.gov (United States)

    Hosono, Hideo; Tanabe, Keiichi; Takayama-Muromachi, Eiji; Kageyama, Hiroshi; Yamanaka, Shoji; Kumakura, Hiroaki; Nohara, Minoru; Hiramatsu, Hidenori; Fujitsu, Satoru

    2015-06-01

    This review shows the highlights of a 4-year-long research project supported by the Japanese Government to explore new superconducting materials and relevant functional materials. The project found several tens of new superconductors by examining ∼1000 materials, each of which was chosen by Japanese experts with a background in solid state chemistry. This review summarizes the major achievements of the project in newly found superconducting materials, and the fabrication wires and tapes of iron-based superconductors; it incorporates a list of ∼700 unsuccessful materials examined for superconductivity in the project. In addition, described are new functional materials and functionalities discovered during the project.

  4. Polyurethane spray coating of aluminum wire bonds to prevent corrosion and suppress resonant oscillations

    CERN Document Server

    Izen, Joseph; The ATLAS collaboration; Kurth, Matthew Glenn

    2015-01-01

    Unencapsulated aluminum wedge wire bonds are common in particle-physics pixel and strip detectors. Industry-favored bulk encapsulation is eschewed due to the range of operating temperatures and radiation. Wire bond failures are a persistent, source of tracking detector failure Unencapsulated bonds are vulnerable to condensation-induced corrosion, particularly when halides are present. Oscillations from periodic Lorenz forces are documented as another source of wire bond failure. Spray application of polyurethane coatings, performance of polyurethane-coated wire bonds after climate chamber exposure, and resonant properties of PU-coated wire bonds and their resistance to periodic Lorenz forces will be described.

  5. A two-dimensional finite element method to calculate the AC loss in superconducting cables, wires and coated conductors

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Z; Jiang, Y; Pei, R; Coombs, T A [Electronic, Power and Energy Conversion Group, Engineering Department, University of Cambridge, CB2 1PZ (United Kingdom); Ye, L [Department of Electrical Power Engineering, CAU, P. O. Box 210, Beijing 100083 (China); Campbell, A M [Interdisciplinary Research Centre in Superconductivity, University of Cambridge, CB3 0HE (United Kingdom)], E-mail: Zh223@cam.ac.uk

    2008-02-15

    In order to utilize HTS conductors in AC electrical devices, it is very important to be able to understand the characteristics of HTS materials in the AC electromagnetic conditions and give an accurate estimate of the AC loss. A numerical method is proposed in this paper to estimate the AC loss in superconducting conductors including MgB{sub 2} wires and YBCO coated conductors. This method is based on solving a set of partial differential equations in which the magnetic field is used as the state variable to get the current and electric field distributions in the cross sections of the conductors and hence the AC loss can be calculated. This method is used to model a single-element and a multi-element MgB{sub 2} wires. The results demonstrate that the multi-element MgB{sub 2} wire has a lower AC loss than a single-element one when carrying the same current. The model is also used to simulate YBCO coated conductors by simplifying the superconducting thin tape into a one-dimensional region where the thickness of the coated conductor can be ignored. The results show a good agreement with the measurement.

  6. Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires.

    Science.gov (United States)

    Muguruma, Takeshi; Iijima, Masahiro; Brantley, William A; Mizoguchi, Itaru

    2011-01-01

    To test the hypothesis that a diamond-like carbon coating does not affect the frictional properties of orthodontic wires. Two types of wires (nickel-titanium and stainless steel) were used, and diamond-like carbon (DLC) films were deposited on the wires. Three types of brackets, a conventional stainless steel bracket and two self-ligating brackets, were used for measuring static friction. DLC layers were observed by three-dimensional scanning electron microscopy (3D-SEM), and the surface roughness was measured. Hardness and elastic modulus were obtained by nanoindentation testing. Frictional forces and surface roughness were compared by the Kruskal-Wallis and Mann-Whitney U-tests. The hardness and elastic modulus of the wires were compared using Student's t-test. When angulation was increased, the DLC-coated wires showed significantly less frictional force than the as-received wires, except for some wire/bracket combinations. Thin DLC layers were observed on the wire surfaces by SEM. As-received and DLC-coated wires had similar surface morphologies, and the DLC-coating process did not affect the surface roughness. The hardness of the surface layer of the DLC-coated wires was much higher than for the as-received wires. The elastic modulus of the surface layer of the DLC-coated stainless steel wire was less than that of the as-received stainless steel wire, whereas similar values were found for the nickel-titanium wires. The hypothesis is rejected. A DLC-coating process does reduce the frictional force.

  7. Bacterial colonization on coated and uncoated orthodontic wires: A prospective clinical trial

    OpenAIRE

    Seyed Hamid Raji; Hasan Shojaei; Parinaz Saeidi Ghorani; Elahe Rafiei

    2014-01-01

    Background: The advantages of coated orthodontic wires such as esthetic and their effects on reduced friction, corrosion and allergic reaction and the significant consequences of plaque accumulation on oral health encouraged us to assess bacterial colonization on these wires. Materials and Methods: A total of 18 (9 upper and 9 lower) epoxy resin coated 16 × 22 nickel-titanium wires (Spectra, GAC, USA) and 18 (9 upper and 9 lower) non-coated 16 × 22 nickel-titanium wires (Sentalloy, GAC, U...

  8. Development of advanced NI alloy substrates with high percentage of cube texture for biaxially oriented YBCO coated tapes

    International Nuclear Information System (INIS)

    HongLi Suo; Yue Zhao; MangMang Gao; Min Liu; YongHua Zhu; PeiKuo Gao; JianHong Wang; Lin Ma; RuiFen Fan; Yuan Ji; MeiLing Zhou

    2009-01-01

    The improvement of mechanical and magnetic properties of textured NiW alloy tapes is considered as a main challenge for RABiTS substrates in coated conductors. The present paper summaries the successful development of several textured NiW substrate tapes with high W contents as well as advanced NiW composite substrates with high strength and reduced magnetization in our previous works. The fabrication process of these tapes and their characterizations are presented in detail. The results on the texture quality and mechanical properties as well as on the magnetic behaviour of these tapes are promising in view of the future application in coated conductor and constitute an alternative to the well known Ni5W alloy substrates. (au)

  9. Bacterial colonization on coated and uncoated orthodontic wires: A prospective clinical trial.

    Science.gov (United States)

    Raji, Seyed Hamid; Shojaei, Hasan; Ghorani, Parinaz Saeidi; Rafiei, Elahe

    2014-11-01

    The advantages of coated orthodontic wires such as esthetic and their effects on reduced friction, corrosion and allergic reaction and the significant consequences of plaque accumulation on oral health encouraged us to assess bacterial colonization on these wires. A total of 18 (9 upper and 9 lower) epoxy resin coated 16 × 22 nickel-titanium wires (Spectra, GAC, USA) and 18 (9 upper and 9 lower) non-coated 16 × 22 nickel-titanium wires (Sentalloy, GAC, USA) with isolated packages were selected and sterilized before application. The samples were divided randomly between upper and lower arches in 18 patients and hence that every patient received one coated and one uncoated wire at the same time. Samples were removed and cut in equal lengths after 3 weeks and placed in phosphate buffered saline buffer. After separation of bacteria in trypsin and ethylenediaminetetraacetic acid solution, the diluted solution was cultured in blood agar and bacterial colony forming units were counted. Finally, the data was analyzed using the paired t-test and the significance was set at 0.05. Mean of bacterial colonization on uncoated wires was more than that of coated wires (P < 0.001). Bacterial plaque accumulation on epoxy resin coated nickel-titanium orthodontic wires is significantly lower than uncoated nickel-titanium wires.

  10. Characterization and coating stability evaluation of nickel-titanium orthodontic esthetic wires: an in vivo study

    Directory of Open Access Journals (Sweden)

    Nina ARGALJI

    2017-08-01

    Full Text Available Abstract The objective of this study was to compare coating dimensions and surface characteristics of two different esthetic covered nickel-titanium orthodontic rectangular archwires, as-received from the manufacturer and after oral exposure. The study was designed for comparative purposes. Both archwires, as-received from the manufacturer, were observed using a stereomicroscope to measure coating thickness and inner metallic dimensions. The wires were also exposed to oral environment in 11 orthodontic active patients for 21 days. After removing the samples, stereomicroscopy images were captured, coating loss was measured and its percentage was calculated. Three segments of each wire (one as-received and two after oral exposure were observed using scanning electron microscopy for a qualitative analysis of the labial surface of the wires. The Lilliefors test and independent t-test were applied to verify normality of data and statistical differences between wires, respectively. The significance level adopted was 0.05. The results showed that the differences between the wires while comparing inner height and thickness were statistically significant (p < 0.0001. In average, the most recently launched wire presented a coating thickness twice that of the control wire, which was also a statistically significant difference. The coating loss percentage was also statistically different (p = 0.0346 when the latest launched wire (13.27% was compared to the control (29.63%. In conclusion, the coating of the most recent wire was thicker and more uniform, whereas the control had a thinner coating on the edges. After oral exposure, both tested wires presented coating loss, but the most recently launched wire exhibited better results.

  11. Characterization and coating stability evaluation of nickel-titanium orthodontic esthetic wires: an in vivo study.

    Science.gov (United States)

    Argalji, Nina; Silva, Eduardo Moreira da; Cury-Saramago, Adriana; Mattos, Claudia Trindade

    2017-08-21

    The objective of this study was to compare coating dimensions and surface characteristics of two different esthetic covered nickel-titanium orthodontic rectangular archwires, as-received from the manufacturer and after oral exposure. The study was designed for comparative purposes. Both archwires, as-received from the manufacturer, were observed using a stereomicroscope to measure coating thickness and inner metallic dimensions. The wires were also exposed to oral environment in 11 orthodontic active patients for 21 days. After removing the samples, stereomicroscopy images were captured, coating loss was measured and its percentage was calculated. Three segments of each wire (one as-received and two after oral exposure) were observed using scanning electron microscopy for a qualitative analysis of the labial surface of the wires. The Lilliefors test and independent t-test were applied to verify normality of data and statistical differences between wires, respectively. The significance level adopted was 0.05. The results showed that the differences between the wires while comparing inner height and thickness were statistically significant (p wire presented a coating thickness twice that of the control wire, which was also a statistically significant difference. The coating loss percentage was also statistically different (p = 0.0346) when the latest launched wire (13.27%) was compared to the control (29.63%). In conclusion, the coating of the most recent wire was thicker and more uniform, whereas the control had a thinner coating on the edges. After oral exposure, both tested wires presented coating loss, but the most recently launched wire exhibited better results.

  12. Deflection and Flexural Strength Effects on the Roughness of Aesthetic-Coated Orthodontic Wires

    OpenAIRE

    Albuquerque, Cibele Gonçalves de; Correr, Américo Bortolazzo; Venezian, Giovana Cherubini; Santamaria Jr, Milton; Tubel, Carlos Alberto; Vedovello, Silvia Amélia Scudeler

    2017-01-01

    Abstract The aim was to evaluate the flexural strength and the effects of deflection on the surface roughness of esthetic orthodontic wires. The sample consisted of 70 archwire 0.014-inch: polytetrafluorethylene (PTFE)-coated Nickel-Titanium (Niti) archwires (Titanol Cosmetic-TC, Flexy Super Elastic Esthetic-FSE, esthetic Nickel Titanium Wire-ANT); epoxy resin-coated Niti archwires (Spectra-S, Niticosmetic-TEC); gold and rhodium coated Niti (Sentalloy-STC) and a control group (superelastic Ni...

  13. Review of effects of dielectric coatings on electrical exploding wires and Z pinches

    Science.gov (United States)

    Wu, Jian; Li, Xingwen; Li, Mo; Li, Yang; Qiu, Aici

    2017-10-01

    As the most powerful x-ray source in the laboratories, the wire array Z pinches have been of great relevance to inertial confinement fusions, laboratory astrophysics, and other high-energy density applications. In order to produce x-ray with greater power and higher efficiency, the dynamics of wire array has been investigated extensively, and various methods have been proposed to improve the implosion quality of the wire array. This review focuses on the experimental and theoretical investigations regarding the effects of the dielectric coatings on electrical exploding wires and Z pinches. Since the early 2000, the electrical wire explosion related to the first stage of the wire array Z pinches has been studied extensively, and the results indicated that the dielectric coatings can significantly increase the joule energy deposition into a wire in the initial stage, and even the corona free explosion of tungsten wires can be achieved. Recently, there is an increasing interest in the dynamics of insulated wire array Z pinches. By applying dielectric coatings, the ablation process is suppressed, the x-ray start time is delayed, and the possibility of multi-peak radiation is decreased. This review is organized by the evolution dynamics of wire array Z pinches, and a broad introduction to relevant scientific concepts and various other applications are presented. According to the current research status, the challenges, opportunities and further developments of Z pinch loads using dielectric coatings are proposed to further promote the researches and their applications.

  14. Review of effects of dielectric coatings on electrical exploding wires and Z pinches

    International Nuclear Information System (INIS)

    Wu, Jian; Li, Mo; Li, Yang; Li, Xingwen; Qiu, Aici

    2017-01-01

    As the most powerful x-ray source in the laboratories, the wire array Z pinches have been of great relevance to inertial confinement fusions, laboratory astrophysics, and other high-energy density applications. In order to produce x-ray with greater power and higher efficiency, the dynamics of wire array has been investigated extensively, and various methods have been proposed to improve the implosion quality of the wire array. This review focuses on the experimental and theoretical investigations regarding the effects of the dielectric coatings on electrical exploding wires and Z pinches. Since the early 2000, the electrical wire explosion related to the first stage of the wire array Z pinches has been studied extensively, and the results indicated that the dielectric coatings can significantly increase the joule energy deposition into a wire in the initial stage, and even the corona free explosion of tungsten wires can be achieved. Recently, there is an increasing interest in the dynamics of insulated wire array Z pinches. By applying dielectric coatings, the ablation process is suppressed, the x-ray start time is delayed, and the possibility of multi-peak radiation is decreased. This review is organized by the evolution dynamics of wire array Z pinches, and a broad introduction to relevant scientific concepts and various other applications are presented. According to the current research status, the challenges, opportunities and further developments of Z pinch loads using dielectric coatings are proposed to further promote the researches and their applications. (topical review)

  15. Polyurethane spray coating of aluminum wire bonds to prevent corrosion and suppress resonant oscillations

    CERN Document Server

    INSPIRE-00092738; Kurth, Matthew; Boyd, Rusty

    2016-01-01

    Unencapsulated aluminum wedge wire bonds are common in particle physics pixel and strip detectors. Industry-favored bulk encapsulation is eschewed due to the range of operating temperatures and radiation. Wire bond failures are a persistent source of tracking-detector failure. Unencapsulated bonds are vulnerable to condensation-induced corrosion, particularly when halides are present. Oscillations from periodic Lorentz forces are documented as another source of wire bond failure. Spray application of polyurethane coatings, performance of polyurethane-coated wire bonds after climate chamber exposure, and resonant properties of polyurethane-coated wire bonds and their resistance to periodic Lorentz forces are under study for use in a future High Luminosity Large Hadron Collider detector such as the ATLAS Inner Tracker upgrade.

  16. Graphene coated subwavelength wires: a theoretical investigation of emission and radiation properties

    International Nuclear Information System (INIS)

    Cuevas, Mauro

    2017-01-01

    Highlights: • Decay rate in a dielectric graphene coated wire. • Localized surface plasmons. • Excitation of multipolar resonances. - Abstract: This work analyzes the emission and radiation properties of a single optical emitter embedded in a graphene–coated subwavelength wire. We discuss the modifications of the spontaneous emission rate and the radiation efficiency as a function of the position and orientation of the dipole inside the wire. Our results show that these quantities can be enhanced by several orders of magnitude when the emission frequency coincides with one of the resonance frequencies of the graphene–coated wire. In particular, high–order plasmon resonances are excited when the emitter is moved from the wire center. Modifications resulting from varying the orientation of the dipole in the near field distribution and in the far field intensities are shown.

  17. Deflection and Flexural Strength Effects on the Roughness of Aesthetic-Coated Orthodontic Wires.

    Science.gov (United States)

    Albuquerque, Cibele Gonçalves de; Correr, Américo Bortolazzo; Venezian, Giovana Cherubini; Santamaria, Milton; Tubel, Carlos Alberto; Vedovello, Silvia Amélia Scudeler

    2017-01-01

    The aim was to evaluate the flexural strength and the effects of deflection on the surface roughness of esthetic orthodontic wires. The sample consisted of 70 archwire 0.014-inch: polytetrafluorethylene (PTFE)-coated Nickel-Titanium (Niti) archwires (Titanol Cosmetic-TC, Flexy Super Elastic Esthetic-FSE, esthetic Nickel Titanium Wire-ANT); epoxy resin-coated Niti archwires (Spectra-S, Niticosmetic-TEC); gold and rhodium coated Niti (Sentalloy-STC) and a control group (superelastic Niti (Nitinol-NS). The initial roughness was evaluated with a rugosimeter. After that, the wires were submitted to flexural test in an universal testing machine. Each wire was deflected up to 2 mm at a speed of 1 mm/min. After flexural test, the roughness of the wires was evaluted on the same surface as that used for the initial evaluation. The data of roughness and flexural strength were analyzed by one-way ANOVA and Tukey's test (a=0.05). Student t-test compared roughness before and after deflection (a =0.05). The roughness of S and ANT (epoxy resin and PTFE-coated wires, respectively), before and after deflection, was significantly higher than the other groups (p<0.05). Wire deflection significantly increased the roughness of the wires S and STC (p<0.05). The flexural strength of groups FSE and NS (PTFE and uncoated) was higher compared with that of the other groups (p<0.05). We concluded that the roughness and flexural strength of the orthodontic wires does not depend on the type of the esthetic coating, but it is influenced by the method of application of this coating. The deflection can increase the roughness of the esthetic orthodontic wires.

  18. Bioactivity and osteointegration of hydroxyapatite-coated stainless steel and titanium wires used for intramedullary osteosynthesis.

    Science.gov (United States)

    Popkov, Arnold V; Gorbach, Elena N; Kononovich, Natalia A; Popkov, Dmitry A; Tverdokhlebov, Sergey I; Shesterikov, Evgeniy V

    2017-08-01

    A lot of research was conducted on the use of various biomaterials in orthopedic surgery. Our study investigated the effects of nanostructured calcium-phosphate coating on metallic implants introduced into the bone marrow canal. Stainless steel or titanium 2-mm wires (groups 1 and 2, respectively), and hydroxyapatite-coated stainless steel or titanium wires of the same diameter (groups 3 and 4, respectively) were introduced into the tibial bone marrow canal of 20 dogs (each group = 5 dogs). Hydroxyapatite coating was deposited on the wires with the method of microarc oxidation. Light microscopy to study histological diaphyseal transverse sections, scanning electron microscopy to study the bone marrow area around the implant and an X-ray electron probe analyzer to study the content of calcium and phosphorus were used to investigate bioactivity and osteointegration after a four weeks period. Osteointegration was also assessed by measuring wires' pull-off strength with a sensor dynamometer. Bone formation was observed round the wires in the bone marrow canal in all the groups. Its intensity depended upon the features of wire surfaces and implant materials. Maximum percentage volume of trabecular bone was present in the bone marrow canals of group 4 dogs that corresponded to a mean of 27.1 ± 0.14%, while it was only 6.7% in group 1. The coating in groups 3 and 4 provided better bioactivity and osteointegration. Hydroxyapatite-coated titanium wires showed the highest degree of bone formation around them and greater pull-off strength. Nanostructured hydroxyapatite coating of metallic wires induces an expressed bone formation and provides osteointegration. Hydroxyapatite-coated wires could be used along with external fixation for bone repair enhancement in diaphyseal fractures, management of osteogenesis imperfecta and correction of bone deformities in phosphate diabetes.

  19. Sliding mechanics of coated composite wires and the development of an engineering model for binding.

    Science.gov (United States)

    Zufall, S W; Kusy, R P

    2000-02-01

    A tribological (friction and wear) study, which was designed to simulate clinical sliding mechanics, was conducted as part of an effort to determine the suitability of poly(chloro-p-xylylene) coatings for composite orthodontic archwires. Prototype composite wires, having stiffnesses similar to those of current initial and intermediate alignment wires, were tested against stainless steel and ceramic brackets in the passive and active configurations (with and without angulation). Kinetic coefficient of friction values, which were determined to quantify sliding resistances as functions of the normal forces of ligation, had a mean that was 72% greater than uncoated wire couples at 0.43. To improve analysis of the active configuration, a mathematical model was developed that related bracket angulation, bracket width, interbracket distance, wire geometry, and wire elastic modulus to sliding resistance. From this model, kinetic coefficients of binding were determined to quantify sliding resistances as functions of the normal forces of binding. The mean binding coefficient was the same as that of uncoated wire couples at 0.42. Although penetrations through the coating were observed on many specimens, the glass-fiber reinforcement within the composite wires was undamaged for all conditions tested. This finding implies that the risk of glass fiber release during clinical use would be eliminated by the coating. In addition, the frictional and binding coefficients were still within the limits outlined by conventional orthodontic wire-bracket couples. Consequently, the coatings were regarded as an improvement to the clinical acceptability of composite orthodontic archwires.

  20. Tunable plasmonic enhancement of light scattering and absorption in graphene-coated subwavelength wires

    OpenAIRE

    Riso, Máximo; Cuevas, Mauro; Depine, Ricardo A.

    2015-01-01

    The electromagnetic response of subwavelength wires coated with a graphene monolayer illuminated by a linearly polarized plane waves is investigated. The results show that the scattering and extintion cross-sections of the coated wire can be dramatically enhanced when the incident radiation resonantly excites localized surface plasmons. The enhancements occur for p--polarized incident waves and for excitation frequencies that correspond to complex poles in the coefficients of the multipole ex...

  1. Life cycle assessment of the application of nanoclays in wire coating

    International Nuclear Information System (INIS)

    Tellaetxe, A; Blázquez, M; Unzueta, I; Arteche, A; Egizabal, A; Ermini, V; Rose, J; Chaurand, P

    2012-01-01

    A life cycle assessment (LCA) is carried out to compare nanoclay-reinforced polymer wire coatings with conventional ones. While the conventional wire coatings contain standard halogen free retardants, in reinforced coatings, montmorillonite (nanoclay) is incorporated into electric cable linings as a rheological agent for an increased resistance to fire. In addition, a reduced load of standard halogen free retardants is obtained. The synergistic effect of the montmorillonite on traditional flame retardant additives (by the formation of a three-dimensional char network) can lead to a revolution in wire production. The application of nanoclays contributes also to anti-dripping effect and flexibility increase. Some producers have already started commercializing wire with nanotechnology-based coating; in the short term the use of nanoclay in wire coating production will probably reach a significant market share replacing traditional formulations. The main aim of this study is to compare the environmental impacts along the life cycle of a traditional wire coating (mineral flame retardants like ATH or MDH in a polymer matrix) with the nanoclay-reinforced wire coating, where the montmorillonite replaces a low percentage of the mineral flame retardant. The system boundaries of the study include the following unit processes: nanoclay production, thermoplastic material and mineral flame retardants production, cable coating manufacturing by extrusion and different end of life scenarios (recycling, incineration and landfill disposal). Whereas nanoreinforced composites have shown and increased fire retardance, the addition of nanomaterials seems to have no significant relevance in the environmental assessment. However, the lack of nano-specific characterization factors for nanomaterials and emission rates associated to the different life cycle stages -mainly in the extrusion and use phase, where accidental combustions can take place- still remains a challenge for realistic life

  2. 7 CFR 1755.702 - Copper coated steel reinforced (CCSR) aerial service wire.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 11 2010-01-01 2010-01-01 false Copper coated steel reinforced (CCSR) aerial service wire. 1755.702 Section 1755.702 Agriculture Regulations of the Department of Agriculture (Continued..., ACCEPTABLE MATERIALS, AND STANDARD CONTRACT FORMS § 1755.702 Copper coated steel reinforced (CCSR) aerial...

  3. PEEK (polyether-ether-ketone)-coated nitinol wire: Film stability for biocompatibility applications

    Energy Technology Data Exchange (ETDEWEB)

    Sheiko, Nataliia [Institut Charles Sadron, C.N.R.S. UPR 22, Université de Strasbourg, 23 rue du Loess, BP 84047, 67034 Strasbourg Cedex 2 (France); Kékicheff, Patrick, E-mail: patrick.kekicheff@ics-cnrs.unistra.fr [Institut Charles Sadron, C.N.R.S. UPR 22, Université de Strasbourg, 23 rue du Loess, BP 84047, 67034 Strasbourg Cedex 2 (France); Marie, Pascal; Schmutz, Marc; Jacomine, Leandro [Institut Charles Sadron, C.N.R.S. UPR 22, Université de Strasbourg, 23 rue du Loess, BP 84047, 67034 Strasbourg Cedex 2 (France); Perrin-Schmitt, Fabienne [Faculté de Médecine, INSERM, UMR-S 1121, “Biomaterials and Bioengineering”, Université de Strasbourg, 11 rue Humann, 67085 Strasbourg Cedex (France)

    2016-12-15

    Highlights: • A thin (12 μm) homogeneous PEEK film without any defects or voids is deposited on NiTi wires. • The coating remains stable in biological environment with negligible Ni ion release and no cytotoxicity. • Large pressure (>2 GPa) can only disrupt the coating film as shown by nanoscratch tests. • Coated spring wires sustain mechanical stress in continuous cycles of axial compression/stretching for >7 million cycles. - Abstract: High quality biocompatible poly-ether-ether-ketone (PEEK) coatings were produced on NiTi shape memory alloy wires using dipping deposition from colloidal aqueous PEEK dispersions after substrate surface treatment. The surface morphology and microstructure were investigated by Scanning Electron Microscopy at every step of the process from the as-received Nitinol substrate to the ultimate PEEK-coated NiTi wire. Nanoscratch tests were carried out to access the adhesive behavior of the polymer coated film to the NiTi. The results indicate that the optimum process conditions in cleaning, chemical etching, and electropolishing the NiTi, were the most important and determining parameters to be achieved. Thus, high quality PEEK coatings were obtained on NiTi wires, straight or curved (even with a U-shape) with a homogeneous microstructure along the wire length and a uniform thickness of 12 μm without any development of cracks or the presence of large voids. The biocompatibility of the PEEK coating film was checked in fibrobast cultured cells. The coating remains stable in biological environment with negligible Ni ion release, no cytotoxicity, and no delamination observed with time.

  4. PEEK (polyether-ether-ketone)-coated nitinol wire: Film stability for biocompatibility applications

    International Nuclear Information System (INIS)

    Sheiko, Nataliia; Kékicheff, Patrick; Marie, Pascal; Schmutz, Marc; Jacomine, Leandro; Perrin-Schmitt, Fabienne

    2016-01-01

    Highlights: • A thin (12 μm) homogeneous PEEK film without any defects or voids is deposited on NiTi wires. • The coating remains stable in biological environment with negligible Ni ion release and no cytotoxicity. • Large pressure (>2 GPa) can only disrupt the coating film as shown by nanoscratch tests. • Coated spring wires sustain mechanical stress in continuous cycles of axial compression/stretching for >7 million cycles. - Abstract: High quality biocompatible poly-ether-ether-ketone (PEEK) coatings were produced on NiTi shape memory alloy wires using dipping deposition from colloidal aqueous PEEK dispersions after substrate surface treatment. The surface morphology and microstructure were investigated by Scanning Electron Microscopy at every step of the process from the as-received Nitinol substrate to the ultimate PEEK-coated NiTi wire. Nanoscratch tests were carried out to access the adhesive behavior of the polymer coated film to the NiTi. The results indicate that the optimum process conditions in cleaning, chemical etching, and electropolishing the NiTi, were the most important and determining parameters to be achieved. Thus, high quality PEEK coatings were obtained on NiTi wires, straight or curved (even with a U-shape) with a homogeneous microstructure along the wire length and a uniform thickness of 12 μm without any development of cracks or the presence of large voids. The biocompatibility of the PEEK coating film was checked in fibrobast cultured cells. The coating remains stable in biological environment with negligible Ni ion release, no cytotoxicity, and no delamination observed with time.

  5. Experiment of enhancing critical current and reducing ac loss in pancake coil comprised of Ni-coated Bi-2223/Ag tape

    International Nuclear Information System (INIS)

    Alamgir, A.K.M.; Gu, C.; Han, Z.

    2006-01-01

    An approach of realizing high performance HTS coil comprised of ferromagnetic material-coated BSCCO tape is proposed. The concept of influencing critical current and ac loss is based on the magnetic shielding effect resulting in redirection of self-field flux-lines. In the previous article, ac performance of Ni-coated tape was demonstrated where the Ni-coating was introduced at the edge-regime of the finished tape in order to redirect the perpendicular component of self-field lines. In order to investigate the shielding effect on ac performance in HTS coil, a two-turn pancake coil comprised of Ni-coated Bi-2223/Ag tape is demonstrated in the present article. About 6.4% of critical current was enhanced and 30% of transport current ac loss was reduced by means of 40 μm thick and 0.3 mm long (from the edge toward center of the tape) Ni-coating. This result suggests that additional ferromagnetic loss could be compensated well by the shielding effect of the partial Ni-coating. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the volume and geometry of ferromagnetic coating introduced. Therefore, it is very important to control the parameter of ferromagnetic coating of the tape in order to balance the critical current and ac loss for optimum coil performance

  6. Experiment of enhancing critical current and reducing ac loss in pancake coil comprised of Ni-coated Bi-2223/Ag tape

    Energy Technology Data Exchange (ETDEWEB)

    Alamgir, A.K.M. [Department of Physics, Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China)]. E-mail: alam643@hotmail.com; Gu, C. [Department of Physics, Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China); Han, Z. [Department of Physics, Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China)

    2006-07-01

    An approach of realizing high performance HTS coil comprised of ferromagnetic material-coated BSCCO tape is proposed. The concept of influencing critical current and ac loss is based on the magnetic shielding effect resulting in redirection of self-field flux-lines. In the previous article, ac performance of Ni-coated tape was demonstrated where the Ni-coating was introduced at the edge-regime of the finished tape in order to redirect the perpendicular component of self-field lines. In order to investigate the shielding effect on ac performance in HTS coil, a two-turn pancake coil comprised of Ni-coated Bi-2223/Ag tape is demonstrated in the present article. About 6.4% of critical current was enhanced and 30% of transport current ac loss was reduced by means of 40 {mu}m thick and 0.3 mm long (from the edge toward center of the tape) Ni-coating. This result suggests that additional ferromagnetic loss could be compensated well by the shielding effect of the partial Ni-coating. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the volume and geometry of ferromagnetic coating introduced. Therefore, it is very important to control the parameter of ferromagnetic coating of the tape in order to balance the critical current and ac loss for optimum coil performance.

  7. Effect of coating on properties of esthetic orthodontic nickel-titanium wires.

    Science.gov (United States)

    Iijima, Masahiro; Muguruma, Takeshi; Brantley, William; Choe, Han-Cheol; Nakagaki, Susumu; Alapati, Satish B; Mizoguchi, Itaru

    2012-03-01

    To determine the effect of coating on the properties of two esthetic orthodontic nickel-titanium wires. Woowa (polymer coating; Dany Harvest) and BioForce High Aesthetic Archwire (metal coating; Dentsply GAC) with cross-section dimensions of 0.016 × 0.022 inches were selected. Noncoated posterior regions of the anterior-coated Woowa and uncoated Sentalloy were used for comparison. Nominal coating compositions were determined by x-ray fluorescence (JSX-3200, JOEL). Cross-sectioned and external surfaces were observed with a scanning electron microscope (SEM; SSX-550, Shimadzu) and an atomic force microscope (SPM-9500J2, Shimadzu). A three-point bending test (12-mm span) was carried out using a universal testing machine (EZ Test, Shimadzu). Hardness and elastic modulus of external and cross-sectioned surfaces were obtained by nanoindentation (ENT-1100a, Elionix; n  =  10). Coatings on Woowa and BioForce High Aesthetic Archwire contained 41% silver and 14% gold, respectively. The coating thickness on Woowa was approximately 10 µm, and the coating thickness on BioForce High Aesthetic Archwire was much smaller. The surfaces of both coated wires were rougher than the noncoated wires. Woowa showed a higher mean unloading force than the noncoated Woowa, although BioForce High Aesthetic Archwire showed a lower mean unloading force than Sentalloy. While cross-sectional surfaces of all wires had similar hardness and elastic modulus, values for the external surface of Woowa were smaller than for the other wires. The coating processes for Woowa and BioForce High Aesthetic Archwire influence bending behavior and surface morphology.

  8. Ceramic membrane by tape casting and sol-gel coating for microfiltration and ultrafiltration application

    Science.gov (United States)

    Das, Nandini; Maiti, H. S.

    2009-11-01

    Alumina membrane filters in the form of thin (0.3-0.8 mm) discs of 25-30 mm diameter suitable for microfiltration application have been fabricated by tape-casting technique. Further using this microfiltration membrane as substrate, boehmite sol coating was applied on it and ultrafiltration membrane with very small thickness was formed. The pore size of the microfiltration membrane could be varied in the range of 0.1-0.7 μm through optimisation of experimental parameter. In addition, each membrane shows a very narrow pore size distribution. The most important factor, which determines the pore size of the membrane, is the initial particle size and its distribution of the ceramic powder. The top thin ultrafiltration, boehmite layer was prepared by sol-gel method, with a thickness of 0.5 μm. Particle size of the sol was approximately 30-40 nm. The structure and formation of the layer was analysed through TEM. At 550 °C formation of the top layer was completed. The pore size of the ultrafiltration membrane measured from TEM micrograph was almost 10 nm. Results of microbial (Escherichia coli—smallest-sized water-borne bacteria) test confirm the possibility of separation through this membrane

  9. Influence of Feedstock Materials and Spray Parameters on Thermal Conductivity of Wire-Arc-Sprayed Coatings

    Science.gov (United States)

    Yao, H. H.; Zhou, Z.; Wang, G. H.; He, D. Y.; Bobzin, K.; Zhao, L.; Öte, M.; Königstein, T.

    2017-03-01

    To manufacture a protective coating with high thermal conductivity on drying cylinders in paper production machines, a FeCrB-cored wire was developed, and the spraying parameters for wire-arc spraying were optimized in this study. The conventional engineering materials FeCrAl and FeCrMo coatings were produced as the reference coatings under the same experimental condition. It has been shown that the oxide content in coating influences the thermal conductivity of coating significantly. The FeCrB coating exhibits a relative higher thermal conductivity due to the lower oxide content in comparison with conventional FeCrAl and FeCrMo coatings. Moreover, the oxidation of in-flight particles can be reduced by decreasing the standoff distance contributing to the increase in the thermal conductivity of coating. Total energy consumption of a papermaking machine can be significantly reduced if the coatings applied to dryer section exhibit high thermal conductivity. Therefore, the FeCrB coating developed in this study is a highly promising coating system for drying cylinders regarding the improved thermal conductivity and low operation costs in paper production industry.

  10. The effects of insulating coatings and current prepulse on tungsten planar wire array Z-pinches

    Energy Technology Data Exchange (ETDEWEB)

    Li, M., E-mail: limo@nint.ac.cn; Li, Y. [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Shaanxi 710049 (China); State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Sheng, L.; Wang, L. P.; Zhao, C.; Yuan, Y.; Zhang, X. J.; Zhang, M.; Peng, B. D.; Zhang, J. H.; Zhang, S. G.; Qiu, M. T. [State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Li, X. W. [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Shaanxi 710049 (China)

    2015-12-15

    This paper presents experimental results on the effects of insulating coatings and current prepulse on tungsten planar wire array Z-pinches on ∼100 ns main current facility. Optical framing images indicated that without a current prepulse the wire ablation process was asymmetrical and the implosion was zippered. The x-ray peak power was ∼320 GW. By using insulating coatings on the wire surface the asymmetry remained, and the processes of ablation and implosion were delayed by ∼30 ns. The x-ray burst was narrow and decreased to ∼200 GW. When current prepulses were used on both standard and insulated wire arrays, implosion symmetry was improved and the x-ray burst was improved (to ∼520 GW peak power). In addition, there was a strong emitting precursor column for insulated loads with the current prepulse.

  11. PEEK (polyether-ether-ketone)-coated nitinol wire: Film stability for biocompatibility applications

    Science.gov (United States)

    Sheiko, Nataliia; Kékicheff, Patrick; Marie, Pascal; Schmutz, Marc; Jacomine, Leandro; Perrin-Schmitt, Fabienne

    2016-12-01

    High quality biocompatible poly-ether-ether-ketone (PEEK) coatings were produced on NiTi shape memory alloy wires using dipping deposition from colloidal aqueous PEEK dispersions after substrate surface treatment. The surface morphology and microstructure were investigated by Scanning Electron Microscopy at every step of the process from the as-received Nitinol substrate to the ultimate PEEK-coated NiTi wire. Nanoscratch tests were carried out to access the adhesive behavior of the polymer coated film to the NiTi. The results indicate that the optimum process conditions in cleaning, chemical etching, and electropolishing the NiTi, were the most important and determining parameters to be achieved. Thus, high quality PEEK coatings were obtained on NiTi wires, straight or curved (even with a U-shape) with a homogeneous microstructure along the wire length and a uniform thickness of 12 μm without any development of cracks or the presence of large voids. The biocompatibility of the PEEK coating film was checked in fibrobast cultured cells. The coating remains stable in biological environment with negligible Ni ion release, no cytotoxicity, and no delamination observed with time.

  12. Enhancement of delamination strength in Cu-stabilized coated conductor tapes through additional treatments under transverse tension at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hyung Seop; Bautista, Zhierwinjay [Andong National University, Andong (Korea, Republic of); Moon, Seung Hyun; Lee, Jae Hun; Mean, Byoung Jean [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2017-06-15

    In superconducting coil applications particularly in wet wound coils, coated conductor (CC) tapes are subjected to different type of stresses that could affect its electromechanical transport property. These include hoop stress acting along the length of the CC tape and the Lorentz force acting perpendicular to the CC tape’s surface. Since the latter is commonly associated with the delamination problem of multi-layered REBCO CC tapes, more understanding and attention on the delamination phenomena induced in the case of coil applications are needed. Difference on the coefficient of thermal expansion (CTE) of each constituent layer of the CC tape, the bobbin, and the impregnating materials is the main causes of delamination in CC tapes when subjected to thermal and mechanical cycling. In the design of degradation-free superconducting coils, therefore, characterization of the delamination behaviors including mechanism and strength in the multi-layered REBCO CC tapes becomes a critical issue. Various trials to increase the delamination strength by improving interface characteristics at interlayers have been performed. In this study, in order to investigate the influences of laser cleaning and Ag annealing treated at the substrate side surface, transverse tensile tests were conducted under different sample configurations using 4.5mm x 8 mm upper anvil. The mechanical delamination strength of differently processed CC samples was examined at room temperature (RT). As a result, the Sample 1 with the additional laser cleaning and Ag annealing processes and the Sample 2 with additional Ag annealing process only showed higher mechanical delamination strength as compared to the Sample 3 without such additional treatments. Sample 3 showed quite different behavior when the loading direction is to the substrate side where the delamination strength much lower as compared to other cases.

  13. Study on Fabrication of Ni-5 at.%W Tapes for Coated Conductors from Cylinder Ingots

    DEFF Research Database (Denmark)

    Ma, L.; Suo, H. L.; Yue, Zhao

    2015-01-01

    Ni-5 at.%W (Ni5W) tapes with a strong cube texture were fabricated using the RABiTS technique and by starting from cylindrical shaped ingots. In contrast to a conventional cuboid-shaped ingot, a cylinder shaped ingot has no anisotropy along the axial direction and the resulting tape will therefore...

  14. Thermoelectric Mechanism and Interface Characteristics of Cyanide-Free Nanogold-Coated Silver Wire

    Science.gov (United States)

    Tseng, Yi-Wei; Hung, Fei-Yi; Lui, Truan-Sheng

    2016-01-01

    Traditional bath-plated gold contains a cyanide complex, which is an environmental hazard. In response, our study used a green plating process to produce cyanide-free gold-coated silver (cyanide-free ACA) bonding wire that has been proven to be a feasible alternative to gold bonding wire in semiconductor packaging. In this work, ACA wire annealed at 550°C was found to have stable microstructure and superior mechanical properties. Intermetallic compounds Ag2Al and AuAl2 grew from Ag-Au balls and Al pads after aging at 175°C for 500 h. After current testing, ACA wire was found to have improved electrical properties due to equiaxed grain growth. The gold nanolayer on the Ag surface increased the oxidation resistance. These results provide insights regarding the reliability of ACA wire in advanced bonding processes.

  15. Wire rod coating process of gas diffusion layers fabrication for proton exchange membrane fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Kannan, A.M.; Sadananda, S.; Parker, D.; Munukutla, L. [Electronic Systems Department, Arizona State University, 7001 E Williams Field Road, Mesa, AZ 85212 (United States); Wertz, J. [Hollingsworth and Vose Co., A.K. Nicholson Research Lab, 219 Townsend Road West Groton, MA 01472 (United States); Thommes, M. [Quantachrome Instruments, 1900 Corporate Drive, Boynton Beach, FL 33426 (United States)

    2008-03-15

    Gas diffusion layers (GDLs) were fabricated using non-woven carbon paper as a macro-porous layer substrate developed by Hollingsworth and Vose Company. A commercially viable coating process was developed using wire rod for coating micro-porous layer by a single pass. The thickness as well as carbon loading in the micro-porous layer was controlled by selecting appropriate wire thickness of the wire rod. Slurry compositions with solid loading as high as 10 wt.% using nano-chain and nano-fiber type carbons were developed using dispersion agents to provide cohesive and homogenous micro-porous layer without any mud-cracking. The surface morphology, wetting characteristics and pore size distribution of the wire rod coated GDLs were examined using FESEM, Goniometer and Hg porosimetry, respectively. The GDLs were evaluated in single cell PEMFC under various operating conditions (temperature and RH) using hydrogen and air as reactants. It was observed that the wire rod coated micro-porous layer with 10 wt.% nano-fibrous carbon based GDLs showed the highest fuel cell performance at 85 C using H{sub 2} and air at 50% RH, compared to all other compositions. (author)

  16. Relationship between friction force and orthodontic force at the leveling stage using a coated wire

    Directory of Open Access Journals (Sweden)

    Masaki MURAYAMA

    2013-12-01

    Full Text Available The relationship between orthodontic force and friction produced from an archwire and brackets affects the sliding of the wire in the leveling stage. Objective: The purpose of this study was to evaluate the relationship between force and friction in a small esthetic nickel-titanium (Ni-Ti wire. Material and Methods: Five esthetic wires (three coated and two plated and two small, plain Ni-Ti wires (0.012 and 0.014 inches were used. We performed a three-point bending test according to ISO 15841 and the drawing test with a dental arch model designed with upper linguoversion of the lateral incisor in the arch (displacements of 0.5, 1.0, 2.0 and 3.0 mm, and evaluated the relationship between them. Results: Unloading bending forces of all wires at displacements of less than 1.0 mm were larger than friction forces, but all friction forces at displacements exceeding 2.0 mm were larger than unloading bending forces. The arch likely expands when displacement from the proximal brackets exceeds 1.0 mm. The friction force of a martensite 0.014-inch Ni-Ti wire was significantly greater than those of the other esthetic and austenitic wires. Conclusions: A wire with the smallest possible friction force should be used in cases with more than 1.0 mm displacement.

  17. Relationship between friction force and orthodontic force at the leveling stage using a coated wire.

    Science.gov (United States)

    Murayama, Masaki; Namura, Yasuhiro; Tamura, Takahiko; Iwai, Hiroaki; Shimizu, Noriyoshi

    2013-01-01

    The relationship between orthodontic force and friction produced from an archwire and brackets affects the sliding of the wire in the leveling stage. The purpose of this study was to evaluate the relationship between force and friction in a small esthetic nickel-titanium (Ni-Ti) wire. Five esthetic wires (three coated and two plated) and two small, plain Ni-Ti wires (0.012 and 0.014 inches) were used. We performed a three-point bending test according to ISO 15841 and the drawing test with a dental arch model designed with upper linguoversion of the lateral incisor in the arch (displacements of 0.5, 1.0, 2.0 and 3.0 mm), and evaluated the relationship between them. Unloading bending forces of all wires at displacements of less than 1.0 mm were larger than friction forces, but all friction forces at displacements exceeding 2.0 mm were larger than unloading bending forces. The arch likely expands when displacement from the proximal brackets exceeds 1.0 mm. The friction force of a martensite 0.014-inch Ni-Ti wire was significantly greater than those of the other esthetic and austenitic wires. A wire with the smallest possible friction force should be used in cases with more than 1.0 mm displacement.

  18. Composite superconducting wires produced by rapid coating in Bi-Sr-Ca-Cu-O metal oxide system

    International Nuclear Information System (INIS)

    Grozav, A.D.; Konopko, L.A.; Leoporda, N.I.

    1989-01-01

    Method for producing superconducting composite wires by dip coating of copper wires in metal-oxide BiSrCaCu 2 O x melt is developed. The thickness of the coating is regulated by the change of dip rate, melt viscosity and by the number of passages through the melt. Wire annealing at 700-800 deg C leads to the production of two phases, one of them being superconducting with T c =80K

  19. The Insulation of Copper Wire by the Electrostatic Coating Process.

    Science.gov (United States)

    1983-06-30

    Caster full production lines produce more uniform coating thicknesses. -18- U AM NC. IO C FWIO~k TX3M ..... ....... Z . A A I~ ~ 15X 7-., r - ’ r 15X... modification to meet specific usage requirements. t * -68- 482 5 APPENDIX CLIQUINITE’ COATING PRODU(:TS LIQUINITEE-COATING POWDERS FEP (Fluorinated Ethylene...Loss from Dissipation Factor (60 Hz-2xl0 9Hz) 0.2-1.2001 Revolving Disc, mg (60 Hz -2 x iO0 Hz) *CS 17 Wheel . 100 cycles 2.2 Surface Resistivity (250

  20. Novel trends in the study of magnetically soft Co-based amorphous glass-coated wires

    International Nuclear Information System (INIS)

    Chiriac, H.; Ovari, T.-A.

    2011-01-01

    An overview of the recent progress and state-of-the-art results in the investigation of the amorphous glass-coated wires with nearly zero magnetostriction is presented. These versatile microwires display enhanced soft magnetic properties, which make them suitable as sensing elements in various sensors for biomedical and automotive applications. Current results on their magnetic characteristics refer to a major refinement of their core-shell magnetic structure by taking into account the interdomain wall and to the thorough analysis of the magnetization within the outer shell. Experimental techniques such as giant magneto-impedance, magneto-resistance, and magneto-optical Kerr effect measurements are employed to prove the outcome of the theoretical calculations. The impact of the magnetic structure of the outer shell on the propagation of domain walls in bistable amorphous wires is analyzed. Very recent results on the magnetization process in nearly zero magnetostrictive amorphous glass-coated wires with submicron dimensions are also reviewed. - Highlights: → The most recent advances in the study of amorphous glass-coated wires with nearly zero magnetostriction are surveyed. → Major progress in the study of their domain structure: the wide interdomain wall, which affects high frequency phenomena. → The magnetization of the outer shell depends on wire diameter and affects the wall propagation in bistable samples. → These novel results are important for future sensor applications of nearly zero magnetostrictive amorphous microwires.

  1. Effects of nanostructured, diamondlike, carbon coating and nitrocarburizing on the frictional properties and biocompatibility of orthodontic stainless steel wires.

    Science.gov (United States)

    Zhang, Hao; Guo, Shuyu; Wang, Dongyue; Zhou, Tingting; Wang, Lin; Ma, Junqing

    2016-09-01

    To evaluate and compare the effects of nanostructured, diamondlike, carbon (DLC) coating and nitrocarburizing on the frictional properties and biocompatibility of orthodontic stainless steel archwires. Plasma-enhanced chemical vapor deposition technology was applied to coat DLC films onto the surface of austenitic stainless steel wires, and salt-bath nitrocarburizing technology was employed to achieve surface hardening of other wires. Surface and cross-sectional characteristics, microhardness, modulus of elasticity, friction resistance, corrosion resistance, and cell toxicity of the modified and control wires were analyzed. The surfaces of the DLC-coated and nitrocarburized wires were both smooth and even. Compared with the control, the DLC-coated wires were increased in surface hardness 1.46 times, decreased in elastic modulus, reduced in kinetic friction coefficient by 40.71%, and decreased in corrosion current density by two orders of magnitude. The nitrocarburized wire was increased in surface hardness 2.39 times, exhibited an unchanged elastic modulus, demonstrated a decrease in maximum static friction force of 22.2%, and rose in corrosion current density two orders of magnitude. Cytotoxicity tests revealed no significant toxicity associated with the modified wires. DLC coating and nitrocarburizing significantly improved the surface hardness of the wires, reduced friction, and exhibited good biocompatibility. The nanostructured DLC coating provided excellent corrosion resistance and good elasticity, and while the nitrocarburizing technique substantially improved frictional properties, it reduced the corrosion resistance of the stainless steel wires to a lesser extent.

  2. Explosion symmetry improvement of polyimide-coated tungsten wire in vacuum on negative discharge facility

    Science.gov (United States)

    Li, Mo; Wu, Jian; Lu, Yihan; Li, Xingwen; Li, Yang; Qiu, Mengtong

    2018-01-01

    Tungsten wire explosion is very asymmetric when fast current rate and insulated coatings are both applied on negative discharge facility using a 24-mm-diameter cathode geometry, which is commonly used on mega-ampere facilities. It is inferred, based on an analytical treatment of the guiding center drift and COMSOL simulations, that the large negative radial electric field causes early voltage breakdown and terminates energy deposition into the wire core on the anode side of the wire. After the anode side is short circuited, the radial electric field along the wire surface on the cathode side will change its polarity and thus leading to additional energy deposition into the wire core. This change causes ˜10 times larger energy deposition and ˜14 times faster explosion velocity in the cathode side than the anode side. In order to reduce this asymmetry, a hollow cylindrical cathode geometry was used to reverse the polarity of radial electric field and was optimized to use on multi-MA facilities. In this case, fully vaporized polyimide-coated tungsten wire with great symmetry improvement was achieved with energy deposition of ˜8.8 eV/atom. The atomic and electronic density distributions for the two different load geometries were obtained by the double-wavelength measurement.

  3. Symmetric tape round REBCO wire with J e (4.2 K, 15 T) beyond 450 A mm-2 at 15 mm bend radius: a viable candidate for future compact accelerator magnet applications

    Science.gov (United States)

    Kar, Soumen; Luo, Wenbo; Ben Yahia, Anis; Li, Xiaofen; Majkic, Goran; Selvamanickam, Venkat

    2018-04-01

    Round REBCO (RE = rare earth) wires of 1.6-1.85 mm diameter have been fabricated using ultrathin REBCO tapes where the superconductor film is positioned near the geometric center. Such symmetric tape round (STAR) wires exhibit excellent tolerance to bend strain with a critical current retention of more than 97% when bent to a radius of 15 mm. A 1.6 mm diameter REBCO STAR wire made with six 2.5 mm wide symmetric tapes reached an engineering current density (J e) of 454 A mm-2 at 4.2 K in a background field of 15 T at a bend radius of 15 mm. Such superior performance at a small bend radius can enable fabrication of future accelerator magnets, operating at magnetic fields above 20 T.

  4. The effect of ZnO nanoparticle coating on the frictional resistance between orthodontic wires and ceramic brackets

    Directory of Open Access Journals (Sweden)

    Ahmad

    2016-06-01

    Full Text Available Background. Any decrease in friction between orthodontic wire and bracket can accelerate tooth movement in the sliding technique and result in better control of anchorage. This study was carried out to evaluate frictional forces by coating orthodontic wires and porcelain brackets with zinc oxide nanoparticles (ZnO. Methods. In this in vitro study, we evaluated a combination of 120 samples of 0.019×0.025 stainless steel (SS orthodontic wires and 22 mil system edgewise porcelain brackets with and without spherical zinc oxide nanoparticles. Spherical ZnO nanoparticles were deposited on wires and brackets by immersing them in ethanol solution and SEM (scanning electron microscope evaluation confirmed the presence of the ZnO coating. The frictional forces were calculated between the wires and brackets in four groups: group ZZ (coated wire and bracket, group OO (uncoated wire and bracket, group ZO (coated wire and uncoated bracket and group OZ (uncoated wire and coated bracket. Kolmogorov-Smirnov, Mann-Whitney and Kruskal-Wallis tests were used for data analysis. Results. The frictional force in ZZ (3.07±0.4 N was the highest (P <0.05, and OZ (2.18±0.5 N had the lowest amount of friction (P <0.05 among the groups. There was no significant difference in frictional forces between the ZO and OO groups (2.65±0.2 and 2.70±0.2 N, respectively. Conclusion. Coating of porcelain bracket surfaces with ZnO nanoparticles can decrease friction in the sliding technique, and wire coating combined with bracket coating is not recommended due to its effect on friction.

  5. Investigation of the influence on residual stresses of porosity in high temperature ZrO2 coatings on Ag tape for magnet technologies

    International Nuclear Information System (INIS)

    Arman, Yusuf; Aktas, Mehmet; Celik, Erdal; Mutlu, Ibrahim H.; Sayman, Onur

    2007-01-01

    The present paper reports on the effect on residual stresses of porosity in high temperature ZrO 2 coatings on Ag tape for magnet technologies. ZrO 2 coatings were fabricated on Ag tape substrate using a reel-to-reel sol-gel system. The microstructural evolution of high temperature ZrO 2 coatings was investigated by a scanning electron microscope (SEM). SEM observations revealed that ZrO 2 coatings with crack had some porosity and mosaic structure. Stress analysis was carried out on ZrO 2 coatings with porosity on Ag tape substrates under cryogenic conditions by using classical lamination theory (CLT) for elastic solution and finite element method (FEM) for elasto-plastic solution in the temperature range of 0 o C to -223 o C in liquid helium media. Because of the static equilibrium, tensile force is applied to the Ag substrate, by ZrO 2 coating. The stress component (σ x ) values change rapidly at coating-substrate interface owing to the different moduli of elasticity and thermal expansion coefficient. In spite of the thickness of Ag substrate, the stress components vary from tensile to compressive. In addition, along the thickness of ZrO 2 coating and Ag substrate system, the stress distribution changes linearly. FEM results demonstrate that the failure does not occur in ZrO 2 coating for all porosities due to its high yield strength

  6. Influence of the Manufacturing Process on Defects in the Galvanized Coating of High Carbon Steel Wires.

    Science.gov (United States)

    Gelfi, Marcello; Solazzi, Luigi; Poli, Sandro

    2017-03-06

    This study is a detailed failure analysis of galvanized high carbon steel wires, which developed coating cracks during the torsion test performed as a quality control at the end of the manufacturing process. Careful visual inspections showed that the cracks are already present in the coating before the torsion test. In order to explain the origin of these cracks, systematic metallographic investigations were performed by means of optical and scanning electron microscope on both the wires and the rods that have been cold drawn to produce the wire. The chemical composition of the galvanized coatings was evaluated by means of energy dispersive spectroscopy. Micro bidimensional X-ray diffraction experiments were also performed to measure the residual stresses in the galvanized coating. The results showed that the failure is related to two main factors: the relatively high content of silicon in the steel and the unsuitable cooling rate of the rods at the exit from the galvanizing bath. The mechanism proposed to explain the origin of the defects was supported by Finite Elements Methods simulations and verified with in-plant tests. The proper countermeasures were then applied and the problem successfully solved.

  7. Influence of the Manufacturing Process on Defects in the Galvanized Coating of High Carbon Steel Wires

    Directory of Open Access Journals (Sweden)

    Marcello Gelfi

    2017-03-01

    Full Text Available This study is a detailed failure analysis of galvanized high carbon steel wires, which developed coating cracks during the torsion test performed as a quality control at the end of the manufacturing process. Careful visual inspections showed that the cracks are already present in the coating before the torsion test. In order to explain the origin of these cracks, systematic metallographic investigations were performed by means of optical and scanning electron microscope on both the wires and the rods that have been cold drawn to produce the wire. The chemical composition of the galvanized coatings was evaluated by means of energy dispersive spectroscopy. Micro bidimensional X-ray diffraction experiments were also performed to measure the residual stresses in the galvanized coating. The results showed that the failure is related to two main factors: the relatively high content of silicon in the steel and the unsuitable cooling rate of the rods at the exit from the galvanizing bath. The mechanism proposed to explain the origin of the defects was supported by Finite Elements Methods simulations and verified with in-plant tests. The proper countermeasures were then applied and the problem successfully solved.

  8. Insulation effect on thermal stability of Coated Conductors wires in liquid nitrogen

    Science.gov (United States)

    Rubeli, Thomas; Dutoit, Bertrand; Martynova, Irina; Makarevich, Artem; Molodyk, Alexander; Samoilenkov, Sergey

    2017-02-01

    Superconducting wires are not perfectly homogeneous in term of critical current as well as stabilization. In resistive fault current limiter applications this could lead to hot spots if the fault current is only slightly above the nominal current of the device. Increasing stabilization by using thicker silver coating for example may prevent this problem but this method implies longer wire length to maintain the same impedance during a fault. Very efficient cooling in another way to prevent hot spots, this can be achieved in nucleate boiling regime. Optimal insulation can be used to prevent film boiling regime, staying in nucleate boiling regime in a much broader temperature range. In this work a novel technique is used to monitor in real time the temperature of the wire during the quench. Using this method several increasing insulation thicknesses are tested, measuring for each the heat exchange rate to the nitrogen bath. Exchange rate measurements are made in quasistatic regime and during the re-cooling of the wire. SuperOx wires provided with different insulation thicknesses exhibit an excellent stability, far above a bare wire. On the other side, for very thick insulations the stability gain is lost. Re-cooling speeds dependency on insulation thicknesses is measured too.

  9. Long-Term Effects of Soldering By-Products on Nickel-Coated Copper Wire

    Science.gov (United States)

    Rolin, T. D.; Hodge, R. E.

    2008-01-01

    An analysis of thirty-year-old, down graded flight cables was conducted to determine the makeup of a green material on the surface of the shielded wire near soldered areas and to ascertain if the green material had corroded the nickel-coated copper wire. Two likely candidates were possible due to the handling and environments to which these cables were exposed. The flux used to solder the cables is known to contain abietic acid, a carboxylic acid found in many pine rosins used for the soldering process. The resulting material copper abietate is green in color and is formed during the application of heat during soldering operations. Copper (II) chloride, which is also green in color is known to contaminate flight parts and is corrosive. Data is presented that shows the material is copper abietate, not copper (II) chloride, and more importantly that the abietate does not aggressively attack nickel-plated copper wire.

  10. Correlations between operating conditions, microstructure and mechanical properties of twin wire arc sprayed steel coatings

    International Nuclear Information System (INIS)

    Jandin, G.; Liao, H.; Feng, Z.Q.; Coddet, C.

    2003-01-01

    An experimental design matrix was set up in which carbon steel coatings were deposited with a twin wire arc spray gun (TAFA 9000 TM ), using either compressed air or nitrogen as spraying gas. The coating's mechanical properties were studied. Some correlations were made between these properties, spraying conditions and the microstructure of the deposits. Young's modulus was estimated by the single beam method using finite element modeling. Results show that direct relationships do exist between spray conditions, oxide content in the coating and microhardness. Young's modulus of the coatings depends on the lamella thickness and the oxide content. When increasing the compressed air flow rate, Young's modulus increases at first because smaller particles and finer lamellae were made and it decreases later because of a higher oxide content. The increase of nitrogen flow rate lowers the oxide content and increases Young's modulus

  11. Investigation about the Chrome Steel Wire Arc Spray Process and the Resulting Coating Properties

    Science.gov (United States)

    Wilden, J.; Bergmann, J. P.; Jahn, S.; Knapp, S.; van Rodijnen, F.; Fischer, G.

    2007-12-01

    Nowadays, wire-arc spraying of chromium steel has gained an important market share for corrosion and wear protection applications. However, detailed studies are the basis for further process optimization. In order to optimize the process parameters and to evaluate the effects of the spray parameters DoE-based experiments had been carried out with high-speed camera shoots. In this article, the effects of spray current, voltage, and atomizing gas pressure on the particle jet properties, mean particle velocity and mean particle temperature and plume width on X46Cr13 wire are presented using an online process monitoring device. Moreover, the properties of the coatings concerning the morphology, composition and phase formation were subject of the investigations using SEM, EDX, and XRD-analysis. These deep investigations allow a defined verification of the influence of process parameters on spray plume and coating properties and are the basis for further process optimization.

  12. Behavior of palladium and its impact on intermetallic growth in palladium-coated Cu wire bonding

    International Nuclear Information System (INIS)

    Xu Hui; Qin, Ivy; Clauberg, Horst; Chylak, Bob; Acoff, Viola L.

    2013-01-01

    This paper describes the behavior of palladium in palladium-coated Cu (PdCu) wire bonding and its impact on bond reliability by utilizing transmission electron microscopy (TEM). A Pd layer approximately 80 nm thick, which is coated on the surface of Cu wire, dissolves into the Cu matrix during ball formation (under N 2 gas protection) when the wire tip is melted to form a ball. As a result of dissolving the very thin Pd layer into the ball, Pd is almost undetectable along the entire bond interface between the ball and the Al pad. The behavior of Pd during thermal aging in air, however, is different for central and peripheral interfaces. At the central interface, less than 5 at.% Pd is present after 168 h aging at 175 °C. At the periphery, however, Pd diffuses back and congregates, reaching a level of ∼12 at.% after 24 h, and a Pd-rich (Cu,Pd) 9 Al 4 layer (>40 at.% Pd) forms after 168 h. Pd acts substitutionally in Cu 9 Al 4 but cannot penetrate into the CuAl 2 or CuAl. By comparison of intermetallic thickness and interfacial morphology between PdCu and bare Cu wire bonds, it is concluded that the presence of Pd reduces intermetallic growth rate, and is associated with numerous nanovoids in PdCu bonds.

  13. Hydrophilic polymer-coated microcatheter-guide wire system for superselective angiographic procedures

    International Nuclear Information System (INIS)

    Kobayashi, Hisashi; Hiraki, Yoshiyuki; Nishimoto, Hidetou; Miyazono, Nobuaki; Satake, Mitsuo; Shinohara, Shinji

    1988-01-01

    A hydrophilic polymer-coated microcatheter-guide wire device has been newly developed for superselective angiography and interventional procedures. The injection rate of this microcatheter was estimated at 2.0 ml/sec. on the maximum pressure of 300 psi when used a non-ionic low osmolar contrast medium, Iopamidol 300. In two of three cases this catheter could make easy insertion into the peripheral branches of the right hepatic artery which were approximately 1 mm in vascular diameter. (author)

  14. Plastohydrodynamic drawing and coating of stainless steel wire using a tapered bore die of no metal to metal contact

    Science.gov (United States)

    Hasan, S.; Basmage, O.; Stokes, J. T.; Hashmi, M. S. J.

    2018-05-01

    A review of wire coating studies using plasto-hydrodynamic pressure shows that most of the works were carried out by conducting experiments simultaneously with simulation analysis based upon Bernoulli's principle and Euler and Navier-Stokes (N-S) equations. These characteristics relate to the domain of Computational Fluid Dynamics (CFD) which is an interdisciplinary topic (Fluid Mechanics, Numerical Analysis of Fluid flow and Computer Science). This research investigates two aspects: (i) simulation work and (ii) experimentation. A mathematical model was developed to investigate the flow pattern of the molten polymer and pressure distribution within the wire-drawing dies, assessment of polymer coating thickness on the coated wires and speed of coating on the wires at the outlet of the drawing dies, without deploying any pressurizing pump. In addition to a physical model which was developed within ANSYS™ environment through the simulation design of ANSYS™ Workbench. The design was customized to simulate the process of wire-coating on the fine stainless-steel wires using drawing dies having different bore geometries such as: stepped parallel bore, tapered bore and combined parallel and tapered bore. The convergence of the designed CFD model and numerical and physical solution parameters for simulation were dynamically monitored for the viscous flow of the polypropylene (PP) polymer. Simulation results were validated against experimental results and used to predict the ideal bore shape to produce a thin coating on stainless wires with different diameter. Simulation studies confirmed that a specific speed should be attained by the stainless-steel wires while passing through the drawing dies. It has been observed that all the speed values within specific speed range did not produce a coating thickness having the desired coating characteristic features. Therefore, some optimization of the experimental set up through design of experiments (Stat-Ease) was applied to

  15. Magneto-optical and electromagnetic studies of core connectivity and weak-link behaviour in Cu/MgB2 and Ni/MgB2 wires and tapes

    International Nuclear Information System (INIS)

    Polyanskii, A; Beilin, V; Felner, I; Tsindlekht, M I; Yashchin, E; Dul'kin, E; Galstyan, E; Roth, M; Senkowicz, B; Hellstrom, E

    2004-01-01

    Critical current density, ac susceptibility (real part χ' and magneto-optical (MO) imaging were used to characterize round wire and tapes made from pre-reacted MgB 2 powder by the powder-in-tube method. Magnetic susceptibility measurements indicated the existence of large-scale weak-link networks in the cores of as-deformed Ni/MgB 2 and Cu/MgB 2 wires and tapes. As-deformed samples showed a two-step transition in χ' versus T traces as evidence of weak links in the tape core. The first heat treatment (HT) of as-deformed tapes led to a sharp susceptibility transition, very strong connection in the tape core as seen in MO images, and high critical current. A second rolling of an as-sintered tape induced a network of defects in the brittle core and gave rise to χ' curve broadening, but did not result in a two-step transition. These data show that deformation-induced cracks are not the primary source of weak-link behaviour. A large decrease in transport current was also registered in this sample. The second HT, for 30 min, restored the sharp magnetic transition and high transport current. Alternating areas of strong and weak connection in the tape core have been observed on MO images. Fast heating and cooling of the as-deformed tape with no dwell time at the maximum temperature resulted in a strongly linked core with a sharp transition and increased transport current. After fast HT, no mechanical defects were observed in MO images. Such fast transformation could be explained by rapid sintering due to highly strained MgB 2 grains

  16. The effect of ZnO nanoparticle coating on the frictional resistance between orthodontic wires and ceramic brackets

    Science.gov (United States)

    Behroozian, Ahmad; Kachoei, Mojgan; Khatamian, Masumeh; Divband, Baharak

    2016-01-01

    Background. Any decrease in friction between orthodontic wire and bracket can accelerate tooth movement in the sliding technique and result in better control of anchorage. This study was carried out to evaluate frictional forces by coating orthodontic wires and porcelain brackets with zinc oxide nanoparticles (ZnO). Methods. In this in vitro study, we evaluated a combination of 120 samples of 0.019×0.025 stainless steel (SS) orthodonticwires and 22 mil system edgewise porcelain brackets with and without spherical zinc oxide nanoparticles. Spherical ZnOnanoparticles were deposited on wires and brackets by immersing them in ethanol solution and SEM (scanning electronmicroscope) evaluation confirmed the presence of the ZnO coating. The frictional forces were calculated between the wiresand brackets in four groups: group ZZ (coated wire and bracket), group OO (uncoated wire and bracket), group ZO (coatedwire and uncoated bracket) and group OZ (uncoated wire and coated bracket). Kolmogorov-Smirnov, Mann-Whitney andKruskal-Wallis tests were used for data analysis. Results. The frictional force in ZZ (3.07±0.4 N) was the highest (P <0.05), and OZ (2.18±0.5 N) had the lowest amount of friction (P <0.05) among the groups. There was no significant difference in frictional forces between the ZO and OO groups (2.65±0.2 and 2.70±0.2 N, respectively). Conclusion. Coating of porcelain bracket surfaces with ZnO nanoparticles can decrease friction in the sliding technique,and wire coating combined with bracket coating is not recommended due to its effect on friction. PMID:27429727

  17. Simulation of fuel rods vibration in power reactors by vibration of tape coated with cadmium

    International Nuclear Information System (INIS)

    Holland, L.

    1982-01-01

    The circulation of cooling water in light water power reactor makes a vibration in internal components. The monitoring of those vibrations is necessary aiming to the safety use of reactors. Aiming at study those vibrations a neutron absorber, type vibratory tape was introduced in the core of a research reactor type Pulstar, operating at 80 W of power. The induced power variations were measured with an ionization chamber put besides the reactor core. The detector signal was recorded and analysed in a PDP-11 computer. The analysis of the results show that the power density of the detector signal, and thus, the power reactor, increase in the O-25 Hz range with an increase in the pulse height vibration. (E.G.) [pt

  18. SPECIFIC FEATURES OF TECHNOLOGY OF MANUFACTURING A ZINC-COATED TUB WIRE FOR MUZZLE (BOTTLE’ HOOD WIRE

    Directory of Open Access Journals (Sweden)

    D. B. Zuev

    2016-01-01

    Full Text Available The paper presents the main technical specifications of galvanized low carbon wire for muzzles (bottle’hood wire, consistent with the exploitation requirements to the wire in the manufacture and use of muzzles. The main criteria when selecting the steel grade and upon selection of the technological processes are given. 

  19. Progress in Effect of Nano-modified Coatings and Welding Process Parameters on Wear of Contact Tube for Non-copper Coated Solid Wires

    Directory of Open Access Journals (Sweden)

    LI Zhuo-xin

    2017-12-01

    Full Text Available Environment-friendly non-copper coated solid wire is the main developing trend for gas shielded solid wires, whereas wear of contact tube limits their wide application. The effect of nano-modified coatings and welding process parameters on wear of contact tube for non-copper coated solid wires was reviewed. It was found that the wear of contact tube can be reduced due to the formation of tribo-films on the rubbing surfaces of welding wires against contact tube; it is feasible to decrease contact tube wear when non-copper coated solid wires are coated with nano-modified lubricants, thereby displaying excellent lubricating and thermal or electrical conduction characteristics. The wear of contact tube increases with the increase of welding current. The wear of contact tube is worse in direct-current electrode positive (DCEP than in direct-current electrode negative (DCEN. Arc ablation and electrical erosion are the dominant wear mechanisms of contact tube.

  20. Fabrication of 100 A class, 1 m long coated conductor tapes by metal organic chemical vapor deposition and pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V.; Lee, H.G.; Li, Y.; Xiong, X.; Qiao, Y.; Reeves, J.; Xie, Y.; Knoll, A.; Lenseth, K

    2003-10-15

    SuperPower has been scaling up YBa{sub 2}Cu{sub 3}O{sub x}-based second-generation superconducting tapes by techniques such as pulsed laser deposition (PLD) using industrial laser and metal organic chemical vapor deposition (MOCVD). Both techniques offer advantage of high deposition rates, which is important for high throughput. Using highly-polished substrates produced in a reel-to-reel polishing facility and buffer layers deposited in a pilot ion beam assisted deposition facility, meter-long second-generation high temperature superconductor tapes have been produced. 100 A class, meter-long coated conductor tapes have been reproducibly demonstrated in this work by both MOCVD and PLD. The best results to date are 148 A over 1.06 m by MOCVD and 135 A over 1.1 m by PLD using industrial laser.

  1. Effect of applied DC electric fields in flame spread over polyethylene-coated electrical wire

    KAUST Repository

    Jin, Young Kyu

    2011-03-01

    We experimentally investigated the effect of applied DC electric fields on the flame spread over polyethylene-coated electrical wire. The flame-spread rates over electrical wire with negative and positive DC electric fields from 0 to ±7 kV were measured and analyzed. We compared the results for DC electric fields with previous results for AC electric fields. We explored whether or not various flame shapes could be obtained with DC electric fields and the main reason for the flame-spread acceleration, particularly at the end of the electrical wire, for AC electric fields. We found that DC electric fields do not significantly affect the flame-spread rates. However, the flame shape is mildly altered by the ionic wind effect even for DC electric fields. The flame-spread rate is relevant to the flame shape and the slanted direction in spite of the mild impact. A possible explanation for the flame spread is given by a thermal-balance mechanism and fuel-vapor jet. © 2011 The Korean Society of Mechanical Engineers.

  2. Proposal to negotiate three collaboration agreements in the context of the Future Circular Collider Study (FCC) concerning the development of HTS coated tapes integrated into the beam screen for impedance mitigation

    CERN Document Server

    2016-01-01

    Proposal to negotiate three collaboration agreements in the context of the Future Circular Collider Study (FCC) concerning the development of HTS coated tapes integrated into the beam screen for impedance mitigation

  3. RESEARCH OF PROCESS OF AN ALLOYING OF THE FUSED COATINGS RECEIVED FROM THE SUPERFICIAL ALLOYED WIRE BY BORON WITH IN ADDITIONALLY APPLIED ELECTROPLATED COATING OF CHROME AND COPPER

    Directory of Open Access Journals (Sweden)

    V. A. Stefanovich

    2015-01-01

    Full Text Available Researches on distribution of chrome and copper in the fused coating received from the superficial alloyed wire by boron with in additionally applied electroplated coating of chrome and copper were executed. The structure of the fused coating consists of dendrites on which borders the boride eutectic is located. It is established that the content of chrome in dendrites is 1,5– 1,6 times less than in the borid; distribution of copper on structure is uniformed. Coefficients of digestion of chrome and copper at an argon-arc welding from a wire electrode with electroplated coating are established. The assimilation coefficient for chrome is equal to 0,9–1,0; for copper – 0,6–0,75.

  4. Magneto-optical investigations of Ag-sheathed Bi-2223 tapes with ferromagnetic shielding

    International Nuclear Information System (INIS)

    Yurchenko, V.V.; Shantsev, D.V.; Galperin, Y.M.; Alamgir, A.K.M.; Han, Z.; Johansen, T.H.

    2007-01-01

    An increase in the critical current and suppression of AC losses in superconducting wires and tapes with soft magnetic sheath have been predicted theoretically and confirmed experimentally. In this work we present the results of magneto-optical investigations on a series of Ag-sheathed Bi-2223 tapes with Ni coating. We visualize distributions of magnetic field at increasing external field and different temperatures, demonstrating a difference between the flux propagation in the superconductor with Ni rims and a reference sample without Ni coating

  5. Magneto-optical investigations of Ag-sheathed Bi-2223 tapes with ferromagnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Yurchenko, V.V.; Shantsev, D.V.; Galperin, Y.M. [University of Oslo, Department of Physics, P.O. Box 1048, Blindern, 0316 Oslo (Norway); Alamgir, A.K.M.; Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China); Johansen, T.H. [University of Oslo, Department of Physics, P.O. Box 1048, Blindern, 0316 Oslo (Norway)], E-mail: tomhj@fys.uio.no

    2007-09-01

    An increase in the critical current and suppression of AC losses in superconducting wires and tapes with soft magnetic sheath have been predicted theoretically and confirmed experimentally. In this work we present the results of magneto-optical investigations on a series of Ag-sheathed Bi-2223 tapes with Ni coating. We visualize distributions of magnetic field at increasing external field and different temperatures, demonstrating a difference between the flux propagation in the superconductor with Ni rims and a reference sample without Ni coating.

  6. REPARATIVE OSTEOGENESIS DURING TREATMENT OF FRACTURE UNDER TRANSOSSEOUS OSTEOSYNTHESIS AND INTRAMEDULLARY INSERTION OF WIRES WITH HYDROXYAPATITE COATING

    Directory of Open Access Journals (Sweden)

    Iurii M. Irianov, Arnold V. Popkov, Nikolay A. Kiryanov, Tatiana Iu. Karaseva, Evgenii A. Karasev

    2015-04-01

    Full Text Available Background: The problem of improving medical care for patients with the locomotor system injuries is very important especially last time. Material and Methods: Canine open comminuted tibial fractures modelled experimentally, wires with hydroxyapatite coating inserted intramedullary, osteosynthesis performed with the Ilizarov fixator. Regenerated bones investigated 14-360 days after surgery using the techniques of light microscopy, scanning and transmission electron microscopy, and X-ray electron probe microanalysis for histologic sections . Results: It has been found that a zone of active reparative osteo- and angiogenesis forms around the wires, as well as a bone sheath with the properties of osteogenesis conductor and inductor. Fracture consolidation occurs early according to the primary type without cartilaginous and connective tissue formation in bone adhesion. Presented morphological characteristics endovasal angiogenesis. Conclusion: The results of the study evidence of the positive effect of intramedullary wires with hydroxyapatite coating on the course and intensity of reparative osteogenesis during fracture healing

  7. Evaluation of mechanical properties of Aluminum-Copper cold sprayed and alloy 625 wire arc sprayed coatings

    Science.gov (United States)

    Bashirzadeh, Milad

    This study examines microstructural-based mechanical properties of Al-Cu composite deposited by cold spraying and wire arc sprayed nickel-based alloy 625 coating using numerical modeling and experimental techniques. The microhardness and elastic modulus of samples were determined using the Knoop hardness technique. Hardness in both transverse and longitudinal directions on the sample cross-sections has been measured. An image-based finite element simulation algorithm was employed to determine the mechanical properties through an inverse analysis. In addition mechanical tests including, tensile, bending, and nano-indentation tests were performed on alloy 625 wire arc sprayed samples. Overall, results from the experimental tests are in relatively good agreement for deposited Al-Cu composites and alloy 625 coating. However, results obtained from numerical simulation are significantly higher in value than experimentally obtained results. Examination and comparison of the results are strong indications of the influence of microstructure characteristics on the mechanical properties of thermally spray deposited coatings.

  8. Investigation on the Tribological Behavior of Arc-Sprayed and Hammer-Peened Coatings Using Tungsten Carbide Cored Wires

    Science.gov (United States)

    Tillmann, W.; Hagen, L.; Schröder, P.

    2017-01-01

    Due to their outstanding properties, WC-W2C iron-based cermet coatings are widely used in the field of wear protection. Regarding commonly used WC-W2C reinforced coating systems, it has been reported that their tribological behavior is mainly determined by the carbide grain size fraction. Although the manufacturing route for arc-sprayed WC-W2C cermet coatings is in an advanced state, there is still a lack of knowledge concerning the performance of cored wires with tungsten carbides as filling material and their related coating properties when post-treatment processes are used such as machine hammer peening (MHP). A major objective was to characterize WC-W2C FeCMnSi coatings, deposited with different carbide grain size fractions as a filling using cored wires, with respect to their tribological behavior. Moreover, deposits derived from cored wires with a different amount of hard phases are investigated. According to this, polished MHP surfaces are compared to as-sprayed and polished samples by means of metallographic investigations. With the use of ball-on-disk and dry rubber wheel tests, dry sliding and rolling wear effects on a microscopic level are scrutinized. It has been shown that the MHP process leads to a densification of the microstructure formation. For dry sliding experiments, the MHP coatings obtain lower wear resistances, but lower coefficients of friction than the conventional coatings. In view of abrasion tests, the MHP coatings possess an improved wear resistance. Strain hardening effects at the subsurface area were revealed by the mechanical response using nanoindentation. However, the MHP process has caused a cracking of embedded carbides, which favor breakouts, leading to advanced third-body wear.

  9. A copper ion-selective electrode with high selectivity prepared by sol-gel and coated wire techniques.

    Science.gov (United States)

    Mazloum Ardakani, M; Salavati-Niasari, M; Khayat Kashani, M; Ghoreishi, S M

    2004-03-01

    A sol-gel electrode and a coated wire ion-selective poly(vinyl chloride) membrane, based on thiosemicarbazone as a neutral carrier, were successfully developed for the detection of Cu (II) in aqueous solutions. The sol-gel electrode and coated electrode exhibited linear response with Nernstian slopes of 29.2 and 28.1 mV per decade respectively, within the copper ion concentration ranges 1.0 x 10(-5) - 1.0 x 10(-1) M and 6.0 x 10(-6) - 1.0 x 10(-1) M for coated and sol-gel sensors. The coated and sol-gel electrodes show detection limits of 3.0 x 10(-6) and 6.0 x 10(-6) M respectively. The electrodes exhibited good selectivities for a number of alkali, alkaline earth, transition and heavy metal ions. The proposed electrodes have response times ranging from 10-50 s to achieve a 95% steady potential for Cu2+ concentration. The electrodes are suitable for use in aqueous solutions over a wide pH range (4-7.5). Applications of these electrodes for the determination of copper in real samples, and as an indicator electrode for potentiometric titration of Cu2+ ion using EDTA, are reported. The lifetimes of the electrodes were tested over a period of six months to investigate their stability. No significant change in the performance of the sol-gel electrode was observed over this period, but after two months the coated wire copper-selective electrode exhibited a gradual decrease in the slope. The selectivity of the sol-gel electrode was found to be better than that of the coated wire copper-selective electrode. Based on these results, a novel sol-gel copper-selective electrode is proposed for the determination of copper, and applied to real sample assays.

  10. Fabrication and properties of Ag-Bi2223 tapes with resistive barriers for filament decoupling

    International Nuclear Information System (INIS)

    Inada, Ryoji; Fukumoto, Yohei; Yasunami, Taeko; Nakamura, Yuichi; Oota, Akio; Li Chengshang; Zhang Pingxiang

    2007-01-01

    In this paper, we prepared the Bi2223 multifilamentary tapes with Ca 2 CuO 3 + Bi2212 as interfilamentary resistive barriers to suppress the electromagnetic coupling among the filaments under AC external magnetic field. The tapes with thin barrier layers of Ca 2 CuO 3 + 30 wt% Bi2212 around the filaments were prepared by using a standard powder-in-tube (PIT) method. The outside surface of monocore Ag-sheathed rods was coated by barrier materials. Then, the several coated monocore wires were stacked and packed into another Ag or Ag-Mg alloy tube. The packed tube was drawn and rolled into tape shape. The tape was subsequently sintered to form Bi2223 phase inside filaments. For the characterization of tapes, X-ray diffraction measurements were performed to investigate the phase formation inside the filaments. The uniformity of transport properties (J c ) for barrier tapes were evaluated on the order of several metre lengths and compared with the result for the tapes without barriers. Finally, AC loss characteristics under AC parallel transverse magnetic field were investigated to examine the effect of introducing the barriers on the filament decoupling

  11. Properties of arc-sprayed coatings from Fe-based cored wires for high-temperature applications

    Science.gov (United States)

    Korobov, Yu. S.; Nevezhin, S. V.; Filiрpov, M. A.; Makarov, A. V.; Malygina, I. Yu.; Fantozzi, D.; Milanti, A.; Koivuluoto, H.; Vuoristo, P.

    2017-12-01

    Equipment of a thermal power plant is subjected to high temperature oxidation and wear. This raises operating costs through frequent repair of worn parts and high metal consumption. The paper proposes a possible solution to this problem through arc spraying of protective coatings. Cored wires of the Fe-Cr-C basic alloying system are used as a feedstock. Additional alloying by Al, B, Si, Ti and Y allows one to create wear- and heat-resistant coatings, which are an attractive substitute of more expensive Co- and Ni-based materials.

  12. Determination of Nd3+ Ions in Solution Samples by a Coated Wire Ion-Selective Sensor

    Directory of Open Access Journals (Sweden)

    Hassan Ali Zamani

    2012-01-01

    Full Text Available A new coated wire electrode (CWE using 5-(methylsulfanyl-3-phenyl-1H-1,2,4-triazole (MPT as an ionophore has been developed as a neodymium ion-selective sensor. The sensor exhibits Nernstian response for the Nd3+ ions in the concentration range of 1.0×10−6-1.0×10−2 M with detection limit of 3.7×10−7 M. It displays a Nernstian slope of 20.2±0.2 mV/decade in the pH range of 2.7–8.1. The proposed sensor also exhibits a fast response time of ∼5 s. The sensor revealed high selectivity with respect to all common alkali, alkaline earth, transition and heavy metal ions, including members of the lanthanide family other than Nd3+. The electrode was used as an indicator electrode in the potentiometric titration of Nd(III ions with EDTA. The electrode was also employed for the determination of the Nd3+ ions concentration in water solution samples.

  13. Fabrication and characterization of gold nano-wires templated on virus-like arrays of tobacco mosaic virus coat proteins

    International Nuclear Information System (INIS)

    Wnęk, M; Stockley, P G; Górzny, M Ł; Evans, S D; Ward, M B; Brydson, R; Wälti, C; Davies, A G

    2013-01-01

    The rod-shaped plant virus tobacco mosaic virus (TMV) is widely used as a nano-fabrication template, and chimeric peptide expression on its major coat protein has extended its potential applications. Here we describe a simple bacterial expression system for production and rapid purification of recombinant chimeric TMV coat protein carrying C-terminal peptide tags. These proteins do not bind TMV RNA or form disks at pH 7. However, they retain the ability to self-assemble into virus-like arrays at acidic pH. C-terminal peptide tags in such arrays are exposed on the protein surface, allowing interaction with target species. We have utilized a C-terminal His-tag to create virus coat protein-templated nano-rods able to bind gold nanoparticles uniformly. These can be transformed into gold nano-wires by deposition of additional gold atoms from solution, followed by thermal annealing. The resistivity of a typical annealed wire created by this approach is significantly less than values reported for other nano-wires made using different bio-templates. This expression construct is therefore a useful additional tool for the creation of chimeric TMV-like nano-rods for bio-templating. (paper)

  14. Fabrication and characterization of gold nano-wires templated on virus-like arrays of tobacco mosaic virus coat proteins

    Science.gov (United States)

    Wnęk, M.; Górzny, M. Ł.; Ward, M. B.; Wälti, C.; Davies, A. G.; Brydson, R.; Evans, S. D.; Stockley, P. G.

    2013-01-01

    The rod-shaped plant virus tobacco mosaic virus (TMV) is widely used as a nano-fabrication template, and chimeric peptide expression on its major coat protein has extended its potential applications. Here we describe a simple bacterial expression system for production and rapid purification of recombinant chimeric TMV coat protein carrying C-terminal peptide tags. These proteins do not bind TMV RNA or form disks at pH 7. However, they retain the ability to self-assemble into virus-like arrays at acidic pH. C-terminal peptide tags in such arrays are exposed on the protein surface, allowing interaction with target species. We have utilized a C-terminal His-tag to create virus coat protein-templated nano-rods able to bind gold nanoparticles uniformly. These can be transformed into gold nano-wires by deposition of additional gold atoms from solution, followed by thermal annealing. The resistivity of a typical annealed wire created by this approach is significantly less than values reported for other nano-wires made using different bio-templates. This expression construct is therefore a useful additional tool for the creation of chimeric TMV-like nano-rods for bio-templating.

  15. Arc-Sprayed Fe-Based Coatings from Cored Wires for Wear and Corrosion Protection in Power Engineering

    Directory of Open Access Journals (Sweden)

    Korobov Yury

    2018-02-01

    Full Text Available High wear and corrosion of parts lead to an increase in operating costs at thermal power plants. The present paper shows a possible solution to this problem through the arc spraying of protective coatings. Cored wires of the base alloying system Fe-Cr-C were used as a feedstock. Rise of wear- and heat-resistance of the coatings was achieved by additional alloying with Al, B, Ti, and Y. The wear and heat resistance of the coatings were tested via a two-body wear test accompanied by microhardness measurement and the gravimetric method, respectively. A high-temperature corrosion test was performed at 550 °C under KCl salt deposition. The porosity and adhesion strengths of the coatings were also evaluated. The microstructure was investigated with a scanning electron microscope (SEM unit equipped with an energy dispersive X-ray (EDX microanalyzer, and the phase composition was assessed by X-ray diffractometry. The test results showed the positive influence of additional alloying with Y on the coating properties. A comparison with commercial boiler materials showed that the coatings have the same level of heat resistance as austenite steels and are an order of magnitude higher than that of pearlite and martensite-ferrite steels. The coatings can be applied to wear- and heat-resistant applications at 20–700 °C.

  16. Microstructural and superconducting properties of high current metal-organic chemical vapor deposition YBa2Cu3O7-δ coated conductor wires

    International Nuclear Information System (INIS)

    Holesinger, T G; Maiorov, B; Ugurlu, O; Civale, L; Chen, Y; Xiong, X; Xie, Y; Selvamanickam, V

    2009-01-01

    Metal-organic chemical vapor deposition (MOCVD) on flexible, ion beam assisted deposition MgO templates has been used to produce high critical current density (J c ) (Y,Sm) 1 Ba 2 Cu 3 O y (REBCO) films suitable for use in producing practical high temperature superconducting (HTS) coated conductor wires. Thick films on tape were produced with sequential additions of 0.7 μm of REBCO via a reel-to-reel progression through a custom-designed MOCVD reactor. Multi-pass processing for thick film deposition is critically dependent upon minimizing surface secondary phase formation. Critical currents (I c s) of up to 600 A/cm width (t = 2.8 μm, J c = 2.6 MA cm -2 , 77 K, self-field) were obtained in short lengths of HTS wires. These high performance MOCVD films are characterized by closely spaced (Y,Sm) 2 O 3 nanoparticle layers that may be tilted relative to the film normal and REBCO orientation. Small shifts in the angular dependence of J c in low and intermediate applied magnetic fields can be associated with the tilted nanoparticle layers. Also present in these films were YCuO 2 nanoplates aligned with the YBCO matrix (short dimension perpendicular to the film normal), threading dislocations, and oriented composite defects (OCDs). The latter structures consist of single or multiple a-axis oriented grains coated on each side with insulating (Y,Sm) 2 O 3 or CuO. The OCDs formed a connected network of insulating phases by the end of the fourth pass. Subsequent attempts at adding additional layers did not increase I c . There is an inconsistency between the measured J c and the observed microstructural degradation that occurs with each additional layer, suggesting that previously deposited layers are improving with each repeated reactor pass. These dynamic changes suggest a role for post-processing to optimize superconducting properties of as-deposited films, addressing issues associated with reproducibility and manufacturing yield.

  17. A review of various nozzle range of wire arc spray on FeCrBMnSi metal coating

    Science.gov (United States)

    Purwaningsih, Hariyati; Rochiem, Rochman; Suchaimi, Muhammad; Jatimurti, Wikan; Wibisono, Alvian Toto; Kurniawan, Budi Agung

    2018-04-01

    Low Temperature Hot Corrosion (LTHC) is type of hot corrosion which occurred on 700-800°C and usually on turbine blades. So, as a result the material of turbine blades is crack and degredation of rotation efficiency. Hot corrosion protection with the use of barrier that separate substrate and environment is one of using metal surface coating, wire arc spray method. This study has a purpose to analyze the effect of nozzle distance and gas pressure on FeCrBMnSi coating process using wire arc spray method on thermal resistance. The parameter of nozzle distance and gas pressure are used, resulted the best parameter on distance 400 mm and gas pressure 3 bar which has the bond strength of 12,58 MPa with porosity percentage of 5,93% and roughness values of 16,36 µm. While the examination of thermal cycle which by heating and cooling continuously, on the coating surface is formed oxide compound (Fe3O4) which cause formed crack propagation and delamination. Beside that hardness of coating surface is increase which caused by precipitate boride (Fe9B)0,2

  18. AC losses in Ag-sheathed Bi2223 tapes with Ca2CuO3 as interfilamentary resistive barriers

    International Nuclear Information System (INIS)

    Inada, R.; Iwata, Y.; Tateyama, K.; Nakamura, Y.; Oota, A.; Zhang, P.X.

    2006-01-01

    In this study, we prepared the Bi2223 multifilamentary tapes with Ca 2 CuO 3 as interfilamentary resistive barriers and evaluated their AC magnetization loss properties at 77 K. The Bi2223 tapes with thin barrier layers of Ca 2 CuO 3 around the filaments were prepared by using a standard powder-in-tube (PIT) method. To fabricate the Ca 2 CuO 3 layers around each filament, the outside surface of monocore Ag-sheathed wires was coated by Ca 2 CuO 3 with the slurry. After the heat treatment to decompose and evaporate the organic binder in the slurry, the several coated monocore wires were stacked and packed into another Ag-tube. Then, the packed tube was drawn and rolled into tape shape. The tape was subsequently sintered to form Bi2223 phase inside filaments. The AC magnetization losses in an AC transverse magnetic field were measured by a pick-up coil method. The loss properties in the barrier tape were compared with those in the tape without barriers. The results indicated that introducing Ca 2 CuO 3 barriers is very effective to suppress the electromagnetic coupling among the filaments and also to reduce the magnetization losses under parallel transverse field

  19. Dynamic resistance of a high-T c coated conductor wire in a perpendicular magnetic field at 77 K

    Science.gov (United States)

    Jiang, Zhenan; Toyomoto, Ryuki; Amemiya, Naoyuki; Zhang, Xingyou; Bumby, Chris W.

    2017-03-01

    Superconducting high-T c coated conductor (CC) wires comprise a ceramic thin film with a large aspect ratio. This geometry can lead to significant dissipative losses when exposed to an alternating magnetic field. Here we report experimental measurements of the ‘dynamic resistance’ of commercially available SuperPower and Fujikura CC wires in an AC perpendicular field. The onset of dynamic resistance occurs at a threshold field amplitude, which is determined by the total DC transport current and the penetration field of the conductor. We show that the field-dependence of the normalised magnetisation loss provides an unambiguous value for this threshold field at zero transport current. From this insight we then obtain an expression for the dynamic resistance in perpendicular field. This approach implies a linear relationship between dynamic resistance and applied field amplitude, and also between threshold field and transport current and this is consistent with our experimental data. The analytical expression obtained yields values that closely agree with measurements obtained across a wide range of frequencies and transport currents, and for multiple CC wires produced by different wire manufacturers and with significantly differing dimensions and critical currents. We further show that at high transport currents, the measured DC resistance includes an additional nonlinear term which is due to flux-flow resistance incurred by the DC transport current. This occurs once the field-dependent critical current of the wire falls below the DC transport current for part of each field cycle. Our results provide an effective and simple approach to calculating the dynamic resistance of a CC wire, at current and field magnitudes consistent with those expected in superconducting machines.

  20. Microstructural studies and wear assessments of Ti/TiC surface composite coatings on commercial pure Ti produced by titanium cored wires and TIG process

    Energy Technology Data Exchange (ETDEWEB)

    Monfared, A., E-mail: amirmonfared25@yahoo.com [Department of Materials Science and Engineering, Sharif University of Technology, Tehran (Iran, Islamic Republic of); Kokabi, A.H.; Asgari, S. [Department of Materials Science and Engineering, Sharif University of Technology, Tehran (Iran, Islamic Republic of)

    2013-01-15

    Tungsten Inert Gas (TIG) process and titanium cored wires filled with micro size TiC particles were employed to produce surface composite coatings on commercial pure Ti substrate for wear resistance improvement. Wire drawing process was utilized to produce several cored wires from titanium strips and titanium carbide powders. Subsequently, these cored wires were melted and coated on commercial pure Ti using TIG process. This procedure was repeated at different current intensities and welding travel speeds. Composite coating tracks were found to be affected by TIG heat input. The microstructural studies using optical and scanning electron microscopy supported by X-ray diffraction showed that the surface composite coatings consisted of {alpha} Prime -Ti, spherical and dendritic TiC particles. Also, greater volume fractions of TiC particles in the coatings were found at lower heat input. A maximum microhardness value of about 1100 HV was measured which is more than 7 times higher than the substrate material. Pin-on-disk wear tests exhibited a better performance of the surface composite coatings than the untreated material which was attributed to the presence of TiC particles in the microstructure. -- Highlights: Black-Right-Pointing-Pointer Ti/TiC composite coatings were produced on the CP-Ti. Black-Right-Pointing-Pointer Titanium cored wire and TIG process were employed for production of the coatings. Black-Right-Pointing-Pointer Decreasing heat input, increased the volume fraction of TiC in the coatings. Black-Right-Pointing-Pointer The maximum microhardness obtained in the lowest heat input. Black-Right-Pointing-Pointer The wear resistance of the coatings improved due to the formation of TiC particles.

  1. Forming Refractory Insulation On Copper Wire

    Science.gov (United States)

    Setlock, J.; Roberts, G.

    1995-01-01

    Alternative insulating process forms flexible coat of uncured refractory insulating material on copper wire. Coated wire formed into coil or other complex shape. Wire-coating apparatus forms "green" coat on copper wire. After wire coiled, heating converts "green" coat to refractory electrical insulator. When cured to final brittle form, insulating material withstands temperatures above melting temperature of wire. Process used to make coils for motors, solenoids, and other electrical devices to be operated at high temperatures.

  2. Development and evolution of biaxial texture of rolled nickel tapes by ion beam bombardment for high Tc coated conductors

    International Nuclear Information System (INIS)

    Wang, S.S.; Wu, K.; Shi, K.; Liu, Q.; Han, Z.

    2004-01-01

    High quality YBa 2 Cu 3 O 7-x films on metallic substrates with high critical current densities well over 10 6 A/cm 2 can be prepared by the rolling assisted biaxially textured substrates (RABiTS) method. Nickel or its alloys have been used as biaxially textured substrates formed through a specific rolling and high temperature annealing procedures. In this paper, we report a newly developed process for developing biaxial texture in rolled Ni tape by argon ion beam bombardment. It is named the ion-beam structure modification (ISM) process. In the ISM processed Ni foils, X-ray diffraction ω scans showed the full width-half maximum (FWHM) value of the (2 0 0) peak was 5.7 deg. . And the electron back scattering diffraction (EBSP) analysis based on scanning electron microscopy showed good {1 0 0} cubic orientation and the mean grain size was determined as about 25 μm. The texture evolution of rolled Ni foils during ISM process is reported also. For ISM process, local temperature elevation and distribution arises from the ion bombardment, coupled with anisotropic incident ion penetration and propagation as a result of channeling effects in the metal lattice, are expected to play the major roles in the development of grain reorientation in the Ni foil. Due to the simplicity and efficiency of the ISM process, the technique shows a great promise for application in the industrial scale production of long-lengths of superconductor tapes

  3. Two-Phase Flow in Wire Coating with Heat Transfer Analysis of an Elastic-Viscous Fluid

    Directory of Open Access Journals (Sweden)

    Zeeshan Khan

    2016-01-01

    Full Text Available This work considers two-phase flow of an elastic-viscous fluid for double-layer coating of wire. The wet-on-wet (WOW coating process is used in this study. The analytical solution of the theoretical model is obtained by Optimal Homotopy Asymptotic Method (OHAM. The expression for the velocity field and temperature distribution for both layers is obtained. The convergence of the obtained series solution is established. The analytical results are verified by Adomian Decomposition Method (ADM. The obtained velocity field is compared with the existing exact solution of the same flow problem of second-grade fluid and with analytical solution of a third-grade fluid. Also, emerging parameters on the solutions are discussed and appropriate conclusions are drawn.

  4. MICROSTRUCTURE FEATURES OF CHROME-NICKEL COATING WELDED WITH FILLER WIRE PL AN-111 WITH A 50% OVERLAP

    Directory of Open Access Journals (Sweden)

    A. G. Belik

    2017-04-01

    Full Text Available Purpose. The paper involves investigation of microstructure features of the coating welded with filler wire PL AN-111 with a 50% beads overlap. Methodology. Wear-resistant layer was formed by means of electric arc deposit welding using filler wire PL AN-111 on the plate from steel 09G2S. Deposit welding was conducted under the following parameters: welding current is of 650-750 A; arc voltage is of 30-34 V; welding speed is of 32 m/h. Microstructure was researched with application of optical microscopies “Neophot-21”, “Nikon Eclipse M200” and electron scanning microscopy JEOL JSM-6510 LV. Microhardness of structural constituentswas measuredwithtesterFM-300 (Future-Tech under loading of 10-50 g. Findings. It is shown that the overlap of the beads leads to the formation of inhomogeneous microstructure in the cross section that varies by zones from free-carbide austenite to hypereutectic microstructure with primary chromium carbides. The analysis of the microhardness of the structural constituents in various coating areas was carried out. It was found that hardness of austenite, carbide eutectic and carbides M7C3 varies in coatings in the range of 3 100-3 850 МPа, 4 100-6 800 МPа and 12 100-15 100 МPа, accordingly. Originality. Authors determined that Cr-Ni coating comprises substantially austenitic-carbide eutectic with different density and thickness of carbide fibers within eutectic colonies. Along the border “base/coating” a single-phase austenitic layer lies which turns into a layer with a hypoeutectic structure. In the heat affected zone from beads fusion austenite disintegration with the granular carbides formation was recorded. This leads to decreasing of matrix corrosion resistance due to chromium depletion. Above the zone of beads fusion, the coating has a hypereutectic structure with the presence of large primary chromium carbides. Practical value. It is shown that deposit welding with filler wire PL AN-111 with a 50

  5. Improvements in or relating to methods of and apparatus for coating wire, rod or strip material by sputtering

    International Nuclear Information System (INIS)

    Wareing, J.B.

    1976-01-01

    A method and apparatus are described for coating wire, rod or strip material comprising first subjecting the material to electron bombardment in a glow discharge to heat and activate the surface and then subjecting it to sputtering by use of a soft cathode discharge. The apparatus comprises a low pressure gas chamber through which the material is passed, and containing a glow discharge electron gun having a tubular cathode shaped so that the material can be passed axially through it, and an anode surrounding the cathode. The cathode is formed in two parts, the first part at one end, being made of material of low sputtering yield, and the second part being formed at least partially of the required coating material. The first part of the cathode may be of stainless steel or Al. The two parts of the cathode are electrically isolated with means provided for applying a lower negative potential, with respect to the anode, to the second part compared with the first part. The voltage applied to the second part may be controlled so as to control the sputtering rate. The gas pressure in the chamber is also controllable. The coating material may be arranged as inserts in the fixed cathode structure or as segments around the surface to be coated, and may be composed of Pb, Zn or Cu. (U.K.)

  6. Replacement of corrosion protection chromate primers and paints used in cryogenic applications on the Space Shuttle with wire arc sprayed aluminum coatings

    Science.gov (United States)

    Daniel, R. L.; Sanders, H. L.; Zimmerman, F. R.

    1995-01-01

    With the advent of new environmental laws restricting volatile organic compounds and hexavalent chrome emissions, 'environmentally safe' thermal spray coatings are being developed to replace the traditional corrosion protection chromate primers. A wire arc sprayed aluminum coating is being developed for corrosion protection of low pressure liquid hydrogen carrying ducts on the Space Shuttle Main Engine. Currently, this hardware utilizes a chromate primer to provide protection against corrosion pitting and stress corrosion cracking induced by the cryogenic operating environment. The wire are sprayed aluminum coating has been found to have good potential to provide corrosion protection for flight hardware in cryogenic applications. The coating development, adhesion test, corrosion test and cryogenic flexibility test results will be presented.

  7. Improvement of slip property of magnetic tape by wet silica surface treatment on cobalt-coating type {gamma}-Fe{sub 2}O{sub 3} magnetic particles; Kobaruto hichakugata {gamma}-Fe{sub 2}O{sub 3} jiseibiryushi no shisshiki shirika hyomenshori niyoru jikitepu no suberi tokusei no kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Kazuyuki; Iwasaki, Keisuke; Tanaka, Yasuyuki; Morii, Hiroko

    1999-02-05

    During the running of a magnetic taper coated with magnetic particles, sometimes troubles of the slip property between the magnetic tape and a magnetic head occur. In this research, silica coating onto the surfaces of magnetic iron oxide particles in water slurry was carried out, and a magnetic tape coated with these surface-modified particles was prepared so as to investigate the effect of the silica coating on the slip property of the magnetic tape. It was found that, for needle cobalt-coating type {gamma}- Fe{sub 2}O{sub 3}, the dynamic friction coefficient of the magnetic tape can be reduced from about 0.4 to abut 0.2 by coating silica at nm order. This was estimated that the adsorption amount of myristic acid as a lubricator component existing in the magnetic tape to the magnetic particles are reduced by the silica coating so that the amount of myristic acid effectively acting on the slip property of the magnetic tape surface is increased. Further, within the investigation scope of the present research, it has been clarified that the magnetic characteristics of the magnetic particles and coating dispersion property are not deteriorated by the surface treatment with silica, and a preferable magnetic recording medium retaining both magnetic characteristic and slip property can be obtained. (translated by NEDO)

  8. Effects of differently hardened brass foil laminate on the electromechanical property of externally laminated CC tapes

    Energy Technology Data Exchange (ETDEWEB)

    Bautista, Zhierwinjay; Shin, Hyung Seop [Dept. of Mechanical Design Engineering, Andong National University, Andong (Korea, Republic of); Mean, Byoung Jean; Lee, Jae Hun [SuNAM Co Ltd., Anseong (Korea, Republic of)

    2016-12-15

    The mechanical properties of REBCO coated conductor (CC) wires under uniaxial tension are largely determined by the thick component layers in the architecture, namely, the substrate and the stabilizer or even the reinforcement layer. Depending on device applications of the CC tapes, it is necessary to reinforce thin metallic foils externally to one-side or both sides of the CC tapes. Due to the external reinforcement of brass foils, it was found that this could increase the reversible strain limit from the Cu-stabilized CC tapes. In this study, the effects of differently hardened brass foil laminate on the electromechanical property of CC tapes were investigated under uniaxial tension loading. The tensile strain dependence of the critical current (I{sub c}) was measured at 77 K and self-field. Depending on whether the I{sub c} of CC tapes were measured during loading or after unloading, a reversible strain (or stress) limit could be determined, respectively. The both-sides of the Cu-stabilized CC tapes were laminated with brass foils with different hardness, namely 1/4H, 1H and EH. From the obtained results, it showed that the yield strength of the brass laminated CC tapes with EH brass foil laminate was comparable to the one of the Cu-stabilized CC tape due to its large yield strength even though its large volume fraction. It was found that the brass foil with different hardness was mainly sensitive on the stress dependence of I{sub c}, but not on the strain sensitivity due to the residual strain induced in the laminated CC tapes during unloading.

  9. Design and Test of a Thermal Triggered Persistent Current System using High Temperature Superconducting Tapes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Keun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Kang, Hyoungku [Electro-Mechanical Research Institute, Hyundai Heavy Industries, Yongin (Korea, Republic of); Ahn, Min Cheol [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yang, Seong Eun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yoon, Yong Soo [Department of Electrical Engineering, Ansan College of Technology, 671 Choji-Dong, Danwon-Gu, Ansan, 425-792 (Korea, Republic of); Lee, Sang Jin [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Ko, Tae Kuk [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of)

    2006-06-01

    A superconducting magnet which is operated in persistent current mode in SMES, NMR, MRI and MAGLEV has many advantages such as high uniformity of magnetic field and reduced thermal loss. A high temperature superconducting (HTS) persistent current switch (PCS) system was designed and tested in this research. The HTS PCS was optimally designed using two different HTS tapes, second generation coated conductor (CC) HTS tape and Bi-2223 HTS tape by the finite element method (FEM) in thermal quench characteristic view. The CC tape is more prospective applicable wire in these days for its high n value and critical current independency from external magnetic field than Bi-2223 tape. Also a prototype PCS system using Bi-2223 tape was manufactured and tested. The PCS system consists of a PCS part, a heater which induces the PCS to quench, and a superconducting magnet. The test was performed in various conditions of transport current. An initial current decay appeared when the superconducting magnet was energized in a PCS system was analyzed. This paper would be foundation of HTS PCS researches.

  10. Development of YBCO tape conductor fabrication technology

    Energy Technology Data Exchange (ETDEWEB)

    Hong, G W; Kim, C J; Lee, H G. and others

    2001-08-01

    Superconductor when fabricated into wire shape is applied for developing electric power transmission cable, transformer, generator and SMES. Such superconducting power devices are capable of maximizing the efficiency of electricity and are anticipated to contribute for solving the energy problem of humankind. Furthermore the high temperature oxide superconductor developed in late 1980s is superconducting above boiling temperature of liquid nitrogen temperature has strong potential to realize superconducting power device and a lot of researches are being done in this field. Superconducting wire is the most important core material for developing superconducting power device and thermo-mechanical powder in tube process was developed to fabricated Ag/Bi-2223 conductor in long length having high critical current carrying capacity. Several companies fabricate and sell Ag/Bi-2223 superconducting wire longer than km length and used for developed electrical power device. But because of its inherent property of sharp decrease in current carrying capacity when applying high magnetic field, the application of Bi-2223 sire is limited as low as 20 K when the power device is in operating under high magnetic field. The YBCO tape conductor has the advantages of maintaining high critical current applying high magnetic field and can be used to most of the power device without special limitation. The metal substrate having good crystallographic texture and deposition technique which can deposit the good quality superconducting thin film continuously in large area are need to fabricate coated conductor, and this technique can be applied to develop the superconducting current limiter or magnetic field shielding device. A superconducting wire for using in high magnetic field is play a critical role in developing maglev, MRI, SMES, transformer, generator and motor and the continuous film deposition technique can be applied in other industry very much.

  11. Operative treatment of acute acromioclavicular dislocations Rockwood III and V-Comparative study between K-wires combined with FiberTape(®) vs. TightRope System(®).

    Science.gov (United States)

    Vrgoč, G; Japjec, M; Jurina, P; Gulan, G; Janković, S; Šebečić, B; Starešinić, M

    2015-11-01

    Acromioclavicular (AC) joint dislocations usually occur in a young active population as a result of a fall on the shoulder. Rockwood divided these dislocations into six types. Optimal treatment is still a matter of discussion. Many operative techniques have been developed, but the main choice is between open and minimally-invasive arthroscopic procedures. The aim of this study was to compare two different surgical methods on two groups of patients to find out which method is superior in terms of benefit to the patient. The methods were evaluated through objective and subjective scores, with a focus on complications and material costs. A retrospective two-centre study was conducted in patients with acute AC joint dislocation Rockwood types III and V. The two methods conducted were an open procedure using K-wires combined with FiberTape(®) (Arthrex, Naples, USA) (Group 1) and an arthroscopic procedure using the TightRope System(®) (Arthrex, Naples, USA) (Group 2). Groups underwent procedures during a two-year period. Diagnosis was based on the clinical and radiographic examination of both AC joints. Surgical treatment and rehabilitation were performed. Sixteen patients were included in this study: Group 1 comprised 10 patients, all male, average age 41.6 years (range 17-64 years), Rockwood type III (eight patients) and Rockwood type V (two patients); Group 2 had six patients, one female and five male, average age 37.8 years (range 18-58 years), Rockwood type III (two patients) and Rockwood type V (four patients). Time from injury to surgery was shorter and patients needed less time to return to daily activities in Group 1. Duration of the surgical procedure was shorter in Group 2 compared with Group 1. Complications of each method were noted. According to the measured scores and operative outcome between dislocation Rockwood type III and V, no significant difference was found. Implant material used in Group 2 was 4.7 times more expensive than that used in Group 1

  12. Flow Injection Analysis of Mercury Using 4-(Dimethylamino Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode

    Directory of Open Access Journals (Sweden)

    Sulaiman Ab Ghani

    2012-11-01

    Full Text Available A flow injection analysis (FIA incorporating a thiosemicarbazone-based coated wire electrode (CWE was developed method for the determination of mercury(II. A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A linear plot within the concentration range of 5 × 10−6–0.1 M Hg(II, slope of 27.8 ± 1 mV per decade and correlation coefficient (R2 of 0.984 were obtained. The system was successfully applied for the determination of mercury(II in dental amalgam solutions and spiked environmental water samples. Highly reproducible measurements with relative standard deviation (RSD < 1% (n = 3 were obtained, giving a typical throughput of 30 samples·h−1.

  13. Conformal bi-layered perovskite/spinel coating on a metallic wire network for solid oxide fuel cells via an electrodeposition-based route

    Science.gov (United States)

    Park, Beom-Kyeong; Song, Rak-Hyun; Lee, Seung-Bok; Lim, Tak-Hyoung; Park, Seok-Joo; Jung, WooChul; Lee, Jong-Won

    2017-04-01

    Solid oxide fuel cells (SOFCs) require low-cost metallic components for current collection from electrodes as well as electrical connection between unit cells; however, the degradation of their electrical properties and surface stability associated with high-temperature oxidation is of great concern. It is thus important to develop protective conducting oxide coatings capable of mitigating the degradation of metallic components under SOFC operating conditions. Here, we report a conformal bi-layered coating composed of perovskite and spinel oxides on a metallic wire network fabricated by a facile electrodeposition-based route. A highly dense, crack-free, and adhesive bi-layered LaMnO3/Co3O4 coating of ∼1.2 μm thickness is conformally formed on the surfaces of wires with ∼100 μm diameter. We demonstrate that the bi-layered LaMnO3/Co3O4 coating plays a key role in improving the power density and durability of a tubular SOFC by stabilizing the surface of the metallic wire network used as a cathode current collector. The electrodeposition-based technique presented in this study offers a low-cost and scalable process to fabricate conformal multi-layered coatings on various metallic structures.

  14. Water Desalination with Wires

    NARCIS (Netherlands)

    Porada, S.; Sales, B.B.; Hamelers, H.V.M.; Biesheuvel, P.M.

    2012-01-01

    We show the significant potential of water desalination using a novel capacitive wire-based technology in which anode/cathode wire pairs are constructed from coating a thin porous carbon electrode layer on top of electrically conducting rods (or wires). By alternately dipping an array of electrode

  15. In situ fabrication of nanostructured titania coating on the surface of titanium wire: A new approach for preparation of solid-phase microextraction fiber

    International Nuclear Information System (INIS)

    Cao Dandan; Lue Jianxia; Liu Jingfu; Jiang Guibin

    2008-01-01

    Nanostructured titania-based solid-phase microextraction (SPME) fibers were fabricated through the in situ oxidation of titanium wires with H 2 O 2 (30%, w/w) at 80 deg. C for 24 h. The obtained SPME fibers possess a ∼1.2 μm thick nanostructured coating consisting of ∼100 nm titania walls and 100-200 nm pores. The use of these fibers for headspace SPME coupled with gas chromatography with electron capture detection (GC-ECD) resulted in improved analysis of dichlorodiphenyltrichloroethane (DDT) and its degradation products. The presented method to detect DDT and its degradation products has high sensitivity (0.20-0.98 ng L -1 ), high precision (relative standard deviation R.S.D. = 9.4-16%, n = 5), a wide linear range (5-5000 ng L -1 ), and good linearity (coefficient of estimation R 2 = 0.991-0.998). As the nanostructured titania was in situ formed on the surface of a titanium wire, the coating was uniformly and strongly adhered on the titanium wire. Because of the inherent chemical stability of the titania coating and the mechanical durability of the titanium wire substrate, this new SPME fiber exhibited long life span (over 150 times)

  16. In situ fabrication of nanostructured titania coating on the surface of titanium wire: A new approach for preparation of solid-phase microextraction fiber

    Energy Technology Data Exchange (ETDEWEB)

    Cao Dandan [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Environmental Science Division, School of Earth and Space Science, University of Science and Technology of China, Hefei, Anhui Province 230026 (China); Lue Jianxia [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China); Liu Jingfu [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China)], E-mail: jfliu@rcees.ac.cn; Jiang Guibin [State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, P.O. Box 2871, Beijing 100085 (China)

    2008-03-17

    Nanostructured titania-based solid-phase microextraction (SPME) fibers were fabricated through the in situ oxidation of titanium wires with H{sub 2}O{sub 2} (30%, w/w) at 80 deg. C for 24 h. The obtained SPME fibers possess a {approx}1.2 {mu}m thick nanostructured coating consisting of {approx}100 nm titania walls and 100-200 nm pores. The use of these fibers for headspace SPME coupled with gas chromatography with electron capture detection (GC-ECD) resulted in improved analysis of dichlorodiphenyltrichloroethane (DDT) and its degradation products. The presented method to detect DDT and its degradation products has high sensitivity (0.20-0.98 ng L{sup -1}), high precision (relative standard deviation R.S.D. = 9.4-16%, n = 5), a wide linear range (5-5000 ng L{sup -1}), and good linearity (coefficient of estimation R{sup 2} = 0.991-0.998). As the nanostructured titania was in situ formed on the surface of a titanium wire, the coating was uniformly and strongly adhered on the titanium wire. Because of the inherent chemical stability of the titania coating and the mechanical durability of the titanium wire substrate, this new SPME fiber exhibited long life span (over 150 times)

  17. Highly Conductive One-Dimensional Manganese Oxide Wires by Coating with Graphene Oxides

    Science.gov (United States)

    Tojo, Tomohiro; Shinohara, Masaki; Fujisawa, Kazunori; Muramatsu, Hiroyuki; Hayashi, Takuya; Ahm Kim, Yoong; Endo, Morinobu

    2012-10-01

    Through coating with graphene oxides, we have developed a chemical route to the bulk production of long, thin manganese oxide (MnO2) nanowires that have high electrical conductivity. The average diameter of these hybrid nanowires is about 25 nm, and their average length is about 800 nm. The high electrical conductivity of these nanowires (ca. 189.51+/-4.51 µS) is ascribed to the homogeneous coating with conductive graphene oxides as well as the presence of non-bonding manganese atoms. The growth mechanism of the nanowires is theoretically supported by the initiation of morphological conversion from graphene oxide to wrapped structures through the formation of covalent bonds between manganese and oxygen atoms at the graphene oxide edge.

  18. Nitrogen implantation into steel wire coated with zinc used as reinforcement in power transmission conductors

    Science.gov (United States)

    Castro-Maldonado, J. J.; Dulcé-Moreno, H. J.; V-Niño, E. D.

    2013-11-01

    In tropical environments, diversity of climatic factors such as temperature, relative humidity, deposition of environmental contaminants (such as sulfates and chlorides) affect a large proportion of materials exposed to the weather, and electrochemical corrosion is one of the phenomena that occur in the case of metals and alloys [1, 2]. It is therefore particularly important to study this behavior in the Zinc-coated steel, since this material is used for its economy in the industry specifically in the area of transport of electricity.

  19. IBM 3480 tape cartridge

    CERN Multimedia

    1984-01-01

    The 3480 tape format is a magnetic tape data storage format developed by IBM. The cartridge contains a single reel. IBM’s 3480 cartridge tape system sought to replace the traditional reels of magnetic tape in the computer center. Because of their speed, reliability, durability and low media cost, these tapes and tape drives are still in high demand. A hallmark of the genre is transferability. Tapes recorded with one tape drive are generally readable on another drive, even if the tape drives were built by different manufacturers.

  20. Trace vanadium analysis by catalytic adsorptive stripping voltammetry using mercury-coated micro-wire and polystyrene-coated bismuth film electrodes

    Energy Technology Data Exchange (ETDEWEB)

    Dansby-Sparks, Royce; Chambers, James Q. [Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600 (United States); Xue Ziling, E-mail: xue@ion.chem.utk.edu [Department of Chemistry, University of Tennessee, Knoxville, TN 37996-1600 (United States)

    2009-06-08

    An electrochemical technique has been developed for ultra-trace (ng L{sup -1}) vanadium (V) measurement. Catalytic adsorptive stripping voltammetry for V analysis was developed at mercury-coated gold micro-wire electrodes (MWEs, 100 {mu}m) in the presence of gallic acid (GA) and bromate ion. A potential of -0.275 V (vs Ag/AgCl) was used to accumulate the complex in acetate buffer (pH 5.0) at the electrode surface followed by a differential pulse voltammetric scan. Parameters affecting the electrochemical response, including pH, concentration of GA and bromate, deposition potential and time have been optimized. Linear response was obtained in the 0-1000 ng L{sup -1} range (2 min deposition), with a detection limit of 0.88 ng L{sup -1}. The method was validated by comparison of results for an unknown solution of V by atomic absorption measurement. The protocol was evaluated in a real sample by measuring the amount of V in river water samples. Thick bismuth film electrodes with protective polystyrene films have also been made and evaluated as a mercury free alternative. However, ng L{sup -1} level detection was only attainable with extended (10 min) deposition times. The proposed use of MWEs for the detection of V is sensitive enough for future use to test V concentration in biological fluids treated by the advanced oxidation process (AOP).

  1. In situ coating nickel organic complexes on free-standing nickel wire films for volumetric-energy-dense supercapacitors.

    Science.gov (United States)

    Hong, Min; Xu, Shusheng; Yao, Lu; Zhou, Chao; Hu, Nantao; Yang, Zhi; Hu, Jing; Zhang, Liying; Zhou, Zhihua; Wei, Hao; Zhang, Yafei

    2018-07-06

    A self-free-standing core-sheath structured hybrid membrane electrodes based on nickel and nickel based metal-organic complexes (Ni@Ni-OC) was designed and constructed for high volumetric supercapacitors. The self-standing Ni@Ni-OC film electrode had a high volumetric specific capacity of 1225.5 C cm -3 at 0.3 A cm -3 and an excellent rate capability. Moreover, when countered with graphene-carbon nanotube (G-CNT) film electrode, the as-assembled Ni@Ni-OC//G-CNT hybrid supercapacitor device delivered an extraordinary volumetric capacitance of 85 F cm -3 at 0.5 A cm -3 and an outstanding energy density of 33.8 at 483 mW cm -3 . Furthermore, the hybrid supercapacitor showed no capacitance loss after 10 000 cycles at 2 A cm -3 , indicating its excellent cycle stability. These fascinating performances can be ascribed to its unique core-sheath structure that high capacity nano-porous nickel based metal-organic complexes (Ni-OC) in situ coated on highly conductive Ni wires. The impressive results presented here may pave the way to construct s self-standing membrane electrode for applications in high volumetric-performance energy storage.

  2. Evaluation of saw damage using diamond-coated wire in crystalline silicon solar cells by photoluminescence imaging

    Science.gov (United States)

    Kinoshita, Kosuke; Kojima, Takuto; Suzuki, Ryota; Kawatsu, Tomoyuki; Nakamura, Kyotaro; Ohshita, Yoshio; Ogura, Atsushi

    2018-05-01

    Si ingots were sliced using a diamond-coated wire, and saw damage was observed even after damage removal etching and texturization. Since invisible microscopic damage was observed only under uncontrolled slice conditions, such damage was identified as saw damage. The wafers with saw damage exhibited the degradation of solar cell conversion efficiency (approximately 1–2% absolute). The results of external quantum efficiency (EQE) measurements showed a slight deterioration of EQE in the short wavelength region. Current–voltage characteristic measurements showed similar results that agreed with the EQE measurement results. In addition, EQE mapping measurements were carried out at various irradiation wavelengths between 350 and 1150 nm. Areas with dark contrasts in EQE mapping correspond to saw damage. In the cells with a low conversion efficiency, both EQE mapping and PL images exhibited dark areas and lines. On the other hand, in the cells with a high conversion efficiency, a uniform distribution of saw damage was observed even with the saw damage in the PL images. We believe that sophisticated control to suppress saw damage during sawing is required to realize higher conversion efficiency solar cells in the future.

  3. Tape transport mechanism

    International Nuclear Information System (INIS)

    Groh, E.F.; McDowell, W.; Modjeski, N.S.; Keefe, D.J.; Groer, P.

    1979-01-01

    A device is provided for transporting, in a stepwise manner, tape between a feed reel and takeup reel. An indexer moves across the normal path of the tape displacing it while the tape on the takeup reel side of the indexer is braked. After displacement, the takeup reel takes up the displaced tape while the tape on the feed reel side of the indexer is braked, providing stepwise tape transport in precise intervals determined by the amount of displacement caused by the indexer

  4. Single-step laser deposition of functionally graded coating by dual ‘wire powder’ or ‘powder powder’ feeding—A comparative study

    Science.gov (United States)

    Syed, Waheed Ul Haq; Pinkerton, Andrew J.; Liu, Zhu; Li, Lin

    2007-07-01

    The creation of iron-copper (Fe-Cu) alloys has practical application in improving the surface heat conduction and corrosion resistance of, for example, conformal cooling channels in steel moulds, but is difficult to achieve because the elements have got low inter-solubility and are prone to solidification cracking. Previous work by these authors has reported a method to produce a graded iron-nickel-copper coating in a single-step by direct diode laser deposition (DLD) of nickel wire and copper powder as a combined feedstock. This work investigates whether dual powder feeds can be used in that process to afford greater geometric flexibility and compares attributes of the 'nickel wire and copper powder' and 'nickel powder and copper powder' processes for deposition on a H13 tool steel substrate. In wire-powder deposition, a higher temperature developed in the melt pool causing a clad with a smooth gradient structure. The nickel powder in powder-powder deposition did not impart much heat into the melt pool so the melt pool solidified with sharp composition boundaries due to single metal melting in some parts. In wire-powder experiments, a graded structure was obtained by varying the flow rates of wire and powder. However, a graded structure was not realised in powder-powder experiments by varying either the feed or the directions. Reasons for the differences and flow patterns in the melt pools and their effect on final part properties of parts produced are discussed.

  5. Microstructural and superconducting properties of high current metal-organic chemical vapor deposition YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} coated conductor wires

    Energy Technology Data Exchange (ETDEWEB)

    Holesinger, T G; Maiorov, B; Ugurlu, O; Civale, L [Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Chen, Y; Xiong, X; Xie, Y; Selvamanickam, V [SuperPower, Inc., Schenectady, NY 12304 (United States)

    2009-04-15

    Metal-organic chemical vapor deposition (MOCVD) on flexible, ion beam assisted deposition MgO templates has been used to produce high critical current density (J{sub c}) (Y,Sm){sub 1}Ba{sub 2}Cu{sub 3}O{sub y} (REBCO) films suitable for use in producing practical high temperature superconducting (HTS) coated conductor wires. Thick films on tape were produced with sequential additions of 0.7 {mu}m of REBCO via a reel-to-reel progression through a custom-designed MOCVD reactor. Multi-pass processing for thick film deposition is critically dependent upon minimizing surface secondary phase formation. Critical currents (I{sub c}s) of up to 600 A/cm width (t = 2.8 {mu}m, J{sub c} = 2.6 MA cm{sup -2}, 77 K, self-field) were obtained in short lengths of HTS wires. These high performance MOCVD films are characterized by closely spaced (Y,Sm){sub 2}O{sub 3} nanoparticle layers that may be tilted relative to the film normal and REBCO orientation. Small shifts in the angular dependence of J{sub c} in low and intermediate applied magnetic fields can be associated with the tilted nanoparticle layers. Also present in these films were YCuO{sub 2} nanoplates aligned with the YBCO matrix (short dimension perpendicular to the film normal), threading dislocations, and oriented composite defects (OCDs). The latter structures consist of single or multiple a-axis oriented grains coated on each side with insulating (Y,Sm){sub 2}O{sub 3} or CuO. The OCDs formed a connected network of insulating phases by the end of the fourth pass. Subsequent attempts at adding additional layers did not increase I{sub c}. There is an inconsistency between the measured J{sub c} and the observed microstructural degradation that occurs with each additional layer, suggesting that previously deposited layers are improving with each repeated reactor pass. These dynamic changes suggest a role for post-processing to optimize superconducting properties of as-deposited films, addressing issues associated with

  6. Progress in American Superconductor’s HTS wire and optimization for fault current limiting systems

    Energy Technology Data Exchange (ETDEWEB)

    Malozemoff, Alexis P., E-mail: amalozemoff@amsc.com

    2016-11-15

    Highlights: • AMSC HTS wire critical current needed for rotating machinery is doubled by 16 MeV Au irradiation. • Nonuniformity of HTS wires in power devices causes hot spot formation during power system faults. • Lower normal-state resistivity and critical current lower HTS wire hot spot heating during faults. • HTS wire hot spot heating in HTS cables during faults must stay below lN{sub 2} bubble nucleation point. • HTS wire can be designed to meet hot spot heating limits in fault current limiting cables. - Abstract: American Superconductor has developed composite coated conductor tape-shaped wires using high temperature superconductor (HTS) on a flexible substrate with laminated metal stabilizer. Such wires enable many applications, each requiring specific optimization. For example, coils for HTS rotating machinery require increased current density J at 25–50 K. A collaboration with Argonne, Brookhaven and Los Alamos National Laboratories and several universities has increased J using an optimized combination of precipitates and ion irradiation defects in the HTS. Major commercial opportunities also exist to enhance electric power grid resiliency by linking substations with distribution-voltage HTS power cables [10]. Such links provide alternative power sources if one substation's transmission-voltage power is compromised. But they must also limit fault currents which would otherwise be increased by such distribution-level links. This can be done in an HTS cable, exploiting the superconductor-to-resistive transition when current exceeds the wires’ critical J. A key insight is that such transitions are usually nonuniform; so the wire must be designed to prevent localized hot spots from damaging the wire or even generating gas bubbles in the cable causing dielectric breakdown. Analysis shows that local heating can be minimized by increasing the composite tape's total thickness, decreasing its total resistance in the normal state and

  7. The preparation and characterization of Bi-2212 film on Ag substrate by dip-coating method

    International Nuclear Information System (INIS)

    Song Yang; Zhao Liang; Li Pei; Qu Timing; Huang Yong; Han Zhenghe

    2006-01-01

    In this paper we report on the processing parameters and resulting critical current densities of Bi 2 Sr 2 Ca 1 Cu 2 O x thick films on Ag substrate. Bi-2212 tapes and wires are prepared by dip-coating method. It is found that parameters during partial melting (maximum process temperature T max and solidification temperature T s ) have strong influences on the transition temperature T c . The 0.5 mm diameter dip-coated wire can carry 4000 A/cm 2 critical current in 77 K, self field. Post-annealing on different temperatures and atmospheres are studied as well to obtain varied T c samples

  8. Improvement of tribological properties of magnetic tape by silica coating onto the Co-{gamma}-Fe{sub 2}O{sub 3} fine particles; Kobaruto hichakugata {gamma}-Fe{sub 2}O{sub 3} jisei biryushi no shisshiki shirika hyomen shori ni yoru jikitepu no suberi tokusei no kaizen

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Kazuyuki; Iwasaki, Keisuke; Tanaka, Yasuyuki; Morii, Hiroko [Toda Kogyo Corporation, Hiroshima (Japan). R and D Center

    1999-01-10

    In order to improve the tribological properties of magnetic tape with Co-{gamma}-Fe{sub 2}O{sub 3} fine particles against a magnetic head, the silica coating onto the surface of Co-{gamma}-Fe{sub 2}O{sub 3} particles in aqueous slurry is investigated experimentally, and the kinetic friction coefficient of magnetic tapes prepared using the coated particles is measured. By this silica coating, the amount of myristic acid absorbed on the Co-{gamma}-Fe{sub 2}O{sub 3} particles tends to decrease and the kinetic friction coefficient of the magnetic tapes can be reduced from 0.4 to 0.2 because of the increase of the effective amount of myristic acid working as the lubricant when the magnetic tape is moving. Since the magnetic properties and the dispersibility of Co-{gamma}-Fe{sub 2}O{sub 3} pigment in the magnetic lacquer are not degraded by the silica coating, this coating method is expected to result in magnetic recording media with both good magnetic and low friction properties. (author)

  9. Composite Cu/Fe/MgB{sub 2} superconducting wires and MgB{sub 2}/YSZ/Hastelloy coated conductors for ac and dc applications

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, B A [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge (United Kingdom); Majoros, M [Interdisciplinary Research Centre in Superconductivity, University of Cambridge, Madingley Road, Cambridge (United Kingdom); Vickers, M [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge (United Kingdom); Eisterer, M [Atomic Institute of the Austrian Universities, A-1020 Vienna (Austria); Toenies, S [Atomic Institute of the Austrian Universities, A-1020 Vienna (Austria); Weber, H W [Atomic Institute of the Austrian Universities, A-1020 Vienna (Austria); Fukutomi, M [National Institute for Materials Science, Superconducting Materials Center, 1-2-1, Sengen, Ibaraki (Japan); Komori, K [National Institute for Materials Science, Superconducting Materials Center, 1-2-1, Sengen, Ibaraki (Japan); Togano, K [National Institute for Materials Science, Superconducting Materials Center, 1-2-1, Sengen, Ibaraki (Japan)

    2003-02-01

    We discuss the results of a study of MgB{sub 2} multifilamentary conductors and coated conductors from the point of view of their future dc and ac applications. The correlation between the slope of the irreversibility line induced by neutron irradiation defects and in situ structural imperfections and the critical temperature and critical current density is discussed with respect to the conductor performance and applicability. We debate the possible origin of the observed anomalous decrease of ac susceptibility at 50 K in copper clad in situ powder-in-tube MgB{sub 2} wires. Different conductor preparation methods and conductor architectures, and attainable critical current densities are presented. Some numerical results on critical currents, thermal stability and ac losses of future MgB{sub 2} multifilamentary and coated conductors with magnetic cladding of their filaments are also discussed.

  10. Tape dig selv!

    DEFF Research Database (Denmark)

    Andersen, Bente Annie Sørine; Neergaard, Christian; Seest, Kristian

    Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives......Håndbog med over 50 tape-teknikker, hvor den klassiske hvide sportstape (Dream Tape) og den originale kinesiotape (Kinesio Tex Gold) bruges. Konkrete anvisninger og praktiske råd gives...

  11. Poly(ionic liquids)-coated stainless-steel wires packed into a polyether ether ketone tube for in-tube solid-phase microextraction.

    Science.gov (United States)

    Feng, Juanjuan; Wang, Xiuqin; Tian, Yu; Luo, Chuannan; Sun, Min

    2017-12-01

    An in-tube solid-phase microextraction device was developed by packing poly(ionic liquids)-coated stainless-steel wires into a polyether ether ketone tube. An anion-exchange process was performed to enhance the extraction performance. Surface properties of poly(ionic liquids)-coated stainless-steel wires were characterized by scanning electron microscopy and energy dispersive X-ray spectrometry. The extraction device was connected to high-performance liquid chromatography equipment to build an online enrichment and analysis system. Ten polycyclic aromatic hydrocarbons were used as model analytes, and important conditions including extraction time and desorption time were optimized. The enrichment factors from 268 to 2497, linear range of 0.03-20 μg/L, detection limits of 0.010-0.020 μg/L, extraction and preparation repeatability with relative standard deviation less than 1.8 and 19%, respectively were given by the established online analysis method. It has been used to detect polycyclic aromatic hydrocarbons in environmental samples, with the relative recovery (5, 10 μg/L) in the range of 85.1-118.9%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Superconducting magnet wire

    Science.gov (United States)

    Schuller, Ivan K.; Ketterson, John B.; Banerjee, Indrajit

    1986-01-01

    A superconducting tape or wire with an improved critical field is formed of alternating layers of a niobium-containing superconductor such as Nb, NbTi, Nb.sub.3 Sn or Nb.sub.3 Ge with a thickness in the range of about 0.5-1.5 times its coherence length, supported and separated by layers of copper with each copper layer having a thickness in the range of about 170-600 .ANG..

  13. Localized etching of an insulator film coated on a copper wire using an atmospheric-pressure microplasma jet.

    Science.gov (United States)

    Yoshiki, Hiroyuki

    2007-04-01

    Atmospheric-pressure microplasma jets (APmicroPJs) of Ar and ArO(2) gases were generated from the tip of a stainless steel surgical needle having outer and inner diameters of 0.4 and 0.2 mm, respectively, with a rf excitation of 13.56 MHz. The steel needle functions both as a powered electrode and a gas nozzle. The operating power is 1.2-6 W and the corresponding peak-to-peak voltage Vp.p. is about 1.5 kV. The APmicroPJ was applied to the localized etching of a polyamide-imide insulator film (thickness of 10 microm) of a copper winding wire of 90 microm diameter. The insulator film around the copper wire was completely removed by the irradiated plasma from a certain direction without fusing the wire. The removal time under the Ar APmicroPJ irradiation was only 3 s at a rf power of 4 W. Fluorescence microscopy and scanning electron microscope images reveal that good selectivity of the insulator film to the copper wire was achieved. In the case of ArO(2) APmicroPJ irradiation with an O(2) concentration of 10% or more, the removed copper surface was converted to copper monoxide CuO.

  14. Localized etching of an insulator film coated on a copper wire using an atmospheric-pressure microplasma jet

    International Nuclear Information System (INIS)

    Yoshiki, Hiroyuki

    2007-01-01

    Atmospheric-pressure microplasma jets (APμPJs) of Ar and Ar/O 2 gases were generated from the tip of a stainless steel surgical needle having outer and inner diameters of 0.4 and 0.2 mm, respectively, with a rf excitation of 13.56 MHz. The steel needle functions both as a powered electrode and a gas nozzle. The operating power is 1.2-6 W and the corresponding peak-to-peak voltage Vp.p. is about 1.5 kV. The APμPJ was applied to the localized etching of a polyamide-imide insulator film (thickness of 10 μm) of a copper winding wire of 90 μm diameter. The insulator film around the copper wire was completely removed by the irradiated plasma from a certain direction without fusing the wire. The removal time under the Ar APμPJ irradiation was only 3 s at a rf power of 4 W. Fluorescence microscopy and scanning electron microscope images reveal that good selectivity of the insulator film to the copper wire was achieved. In the case of Ar/O 2 APμPJ irradiation with an O 2 concentration of 10% or more, the removed copper surface was converted to copper monoxide CuO

  15. Reliability Criteria for Thick Bonding Wire.

    Science.gov (United States)

    Dagdelen, Turker; Abdel-Rahman, Eihab; Yavuz, Mustafa

    2018-04-17

    Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.

  16. Reliability Criteria for Thick Bonding Wire

    Directory of Open Access Journals (Sweden)

    Turker Dagdelen

    2018-04-01

    Full Text Available Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al and aluminum coated copper (CucorAl wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.

  17. Reliability Criteria for Thick Bonding Wire

    Science.gov (United States)

    Yavuz, Mustafa

    2018-01-01

    Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire. PMID:29673194

  18. Anisotropy of the critical current in MgB2 tapes made of high energy milled precursor powder

    DEFF Research Database (Denmark)

    Hässler, W.; Kovac, P.; Eisterer, M.

    2010-01-01

    For applications of MgB2 wires or tapes, high critical currents in high magnetic fields are essential. By using tapes in superconducting coils the anisotropic behaviour of the critical current, i.e. the dependence on the direction of the external field in relation to the tape surface, has to be t...

  19. Reel-to-reel substrate tape polishing system

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, Venkat; Gardner, Michael T.; Judd, Raymond D.; Weloth, Martin; Qiao, Yunfei

    2005-06-21

    Disclosed is a reel-to-reel single-pass mechanical polishing system (100) suitable for polishing long lengths of metal substrate tape (124) used in the manufacture of high-temperature superconductor (HTS) coated tape, including multiple instantiations of a polishing station (114) in combination with a subsequent rinsing station (116) arranged along the axis of the metal substrate tape (124) that is translating between a payout spool (110a) and a take-up spool (110b). The metal substrate tape obtains a surface smoothness that is suitable for the subsequent deposition of a buffer layer.

  20. Peculiar features of metallurgical processes at plasma-arc spraying of coatings, made of steel wire with powder fillers B4C and B4C+ZrO2

    Directory of Open Access Journals (Sweden)

    Георгій Михайлович Григоренко

    2016-11-01

    Full Text Available The interaction of metallurgical processes occurring in plasma-arc spraying between the steel shell and the carbide fillers of B4C and B4C cored wires with the addition of nanocrystalline ZrO2 powder has been analyzed. Iron-boron compounds alloyed with carbon are formed in ingots as a result of ferritiс coating of wire interacrion with fillers while the ferritic matrix contains boride and carboboride eutectics. Average microhardness of the carboboride compounds and the matrix is high – 17,78; 16,40 and 8,69; 9,95 GPa for the ingots with с B4C and B4C+ZrO2 respectively. The best quality coatings with low porosity (~1%, lamellar structure consisting of ferrite matrix reinforced with dispersed Fe borides, were obtained at a higher heat input (plasmatron current 240-250 A. The average amount of oxides in the coatings makes 15%. 0,5% addition of nanopowder ZrO2 accelerates dispersed iron-boron compounds forming, promotes their uniform distribution in the structure and improves coating microhardness up to 7,0 GPa. Application of the differential thermal analysis method to simulate the interaction processes between the steel shell and the filler during the heating of wire in the shielding gas makes it possible to promote formation of new phases (borides and carboborides of iron and to predict the phase composition of the coatings

  1. Engineering Critical Current Density Improvement in Ag- Bi-2223 Tapes

    DEFF Research Database (Denmark)

    Wang, W. G.; Seifi, Behrouz; Eriksen, Morten

    2000-01-01

    Ag alloy sheathed Bi-2223 multifilament tapes were produced by the powder-in-tube method. Engineering critical current density improvement has been achieved through both enhancement of critical current density by control of the thermal behavior of oxide powder and by an increase of the filling...... factor of the tapes. Phase evolution at initial sintering stage has been studied by a quench experiment in Ag-Bi-2223 tapes. The content, texture, and microstructure of various phases were determined by XRD and SEM. A novel process approach has been invented in which square wire was chosen rather than...

  2. Caught (Unfortunately) on Tape

    Science.gov (United States)

    Young, Jeffrey R.

    2009-01-01

    Recording class sessions so students can view them online is becoming routine on many campuses. But all that taping can lead to "uh-oh moments," such as when a professor's joke about the college dean ends up on YouTube, or a private comment to a student after class is inadvertently broadcast. Some lecture bloopers caught on tape are…

  3. New crosslinked polyvinyl chloride insulated wire by electron beam irradiation

    International Nuclear Information System (INIS)

    Takahata, Norio; Shingyouchi, Kazuo; Sato, Masakatsu; Sasaki, Hidemi; Terunuma, Haruji

    1978-01-01

    The polyvinyl chloride-coated wires crosslinked by electron beam irradiation have made rapid progress as electric and electronic wiring material and grown to hold a firm position in this field. In response to the requirements for wires with the advance of electronic equipments, Hitachi Cable Ltd. developed a peculiar graft polymer consisting of chlorinated polyethylene and polyvinyl chloride. To this polymer, the characteristics of a very wide range from toughness to flexibility can be given, and the crosslinked polyvinyl chloride wires utilizing these characteristics were put in practical use. Many kinds of the wires were developed as follows; 105 deg. C rating crosslinked vinyl-coated wires authorized by UL and CSA standards, crosslinked vinyl-coated wires with excellent flexibility, high strength crosslinked vinyl-coated wires with thin coating and crosslinked vinyl-coated wires for automobiles. They are expected to be developed into other new fields and applications. (Kobatake, H.)

  4. Influence of thickness of zinc coating on CMT welding-brazing with AlSi5 alloy wire

    Science.gov (United States)

    Jin, Pengli; Wang, Zhiping; Yang, Sinan; Jia, Peng

    2018-03-01

    Effect of thickness of zinc coating on Cold Mattel Transfer (CMT) brazing of aluminum and galvanized steel is investigated. The thickness of zinc coating is 10 μm, 30 μm, and 60 μm, respectively. A high-speed camera was used to capture images of welding process of different specimens; the microstructure and composition analyses of the welding seam were examined by scanning electron microscopy (SEM) and energy dispersive spectrometer (EDS); the mechanical properties were measured in the form of Nano-indentation experiments. The results showed that arc characteristics and metal transfer behavior were unsteady at the beginning of welding process and that became stable after two cycles of CMT. With the thickness of zinc coating thickening, arc characteristics and metal transfer behaviors were more deteriorated. Compared with 10 μm and 30 μm, clad appearance of 60 μm was straight seam edges and a smooth surface which wetting angle was 60°. Zinc-rich zone at the seam edges was formed by zinc dissolution and motel pool oscillating, and zinc content of 10 μm and 30 μm were 5.8% and 7.75%. Zinc content of 60 μm was 14.61%, and it was a belt between galvanized steel and welding seam. The thickness of intermetallic compounds layer was in the range of 1-8 μm, and it changed with the thickness of zinc coating. The average hardness of the reaction layer of 60 μm is 9.197 GPa.

  5. Strategic flat rolling of Ag/BSCCO-2223 tapes

    DEFF Research Database (Denmark)

    Nielsen, Morten Storgård; Bech, Jakob Ilsted; Eriksen, Morten

    2002-01-01

    In the process of single-step flat rolling of multifilament Ag/BSCCO-2223 wire to tape previous work has shown the optimum strategy giving maximum critical current density to be it balance between the length and width strain, so they are of equal size i.e. so, that the logarithmic strain ratio, L...

  6. Structuring of Functional Spider Silk Wires, Coatings, and Sheets by Self-Assembly on Superhydrophobic Pillar Surfaces.

    Science.gov (United States)

    Gustafsson, Linnea; Jansson, Ronnie; Hedhammar, My; van der Wijngaart, Wouter

    2018-01-01

    Spider silk has recently become a material of high interest for a large number of biomedical applications. Previous work on structuring of silk has resulted in particles (0D), fibers (1D), films (2D), and foams, gels, capsules, or microspheres (3D). However, the manufacturing process of these structures is complex and involves posttreatment of chemicals unsuitable for biological applications. In this work, the self-assembly of recombinant spider silk on micropatterned superhydrophobic surfaces is studied. For the first time, structuring of recombinant spider silk is achieved using superhydrophobic surfaces under conditions that retain the bioactivity of the functionalized silk. By tuning the superhydrophobic surface geometry and the silk solution handling parameters, this approach allows controlled generation of silk coatings, nanowires, and sheets. The underlying mechanisms and governing parameters are discussed. It is believed that the results of this work pave the way for fabrication of silk formations for applications including vehicles for drug delivery, optical sensing, antimicrobial coatings, and cell culture scaffolds. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. The Imation 9840 Tape Cartridge

    CERN Multimedia

    It’s a 20 GB uncompressed center-load cartridge used in StorageTek T9840 tape drives. The tape is a Metal Particle (MP) tape suitable for use on all Oracle/Sun/StorageTek 9840 A, B, C and D drives. The 9840 tape has an archival life of 15-30 years.

  8. Rapid in situ growth of oriented titanium-nickel oxide composite nanotubes arrays coated on a nitinol wire as a solid-phase microextraction fiber coupled to HPLC-UV.

    Science.gov (United States)

    Zhen, Qi; Zhang, Min; Song, Wenlan; Wang, Huiju; Wang, Xuemei; Du, Xinzhen

    2016-10-01

    An oriented titanium-nickel oxide composite nanotubes coating was in situ grown on a nitinol wire by direct electrochemical anodization in ethylene glycol with ammonium fluoride and water for the first time. The morphology and composition of the resulting coating showed that the anodized nitinol wire provided a titania-rich coating. The titanium-nickel oxide composite nanotubes coated fiber was used for solid-phase microextraction of different aromatic compounds coupled to high-performance liquid chromatography with UV detection. The titanium-nickel oxide composite nanotubes coating exhibited high extraction capability, good selectivity, and rapid mass transfer for weakly polar UV filters. Thereafter the important parameters affecting extraction efficiency were investigated for solid-phase microextraction of UV filters. Under the optimized conditions, the calibration curves were linear in the range of 0.1-300 μg/L for target UV filters with limits of detection of 0.019-0.082 μg/L. The intraday and interday precision of the proposed method with the single fiber were 5.3-7.2 and 5.9-7.9%, respectively, and the fiber-to-fiber reproducibility ranged from 6.3 to 8.9% for four fibers fabricated in different batches. Finally, its applicability was evaluated by the extraction and determination of target UV filters in environmental water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Moessbauer spectroscopy studies of spin reorientations in amorphous and crystalline (Co0.2Fe0.8)72.5Si12.5B15 glass coated micro-wires

    International Nuclear Information System (INIS)

    Nowik, I.; Felner, I.; Garcia-Miquel, H.

    2007-01-01

    Thermo-gravimetric, differential scanning calorimetry and comprehensive 57 Fe Moessbauer spectroscopy studies of amorphous and crystalline ferromagnetic glass coated (Co 0.2 Fe 0.8 ) 72.5 Si 12.5 B 15 micro-wires have been recorded. The Curie temperature of the amorphous phase is T C (amorp) ∼730 K. The analysis of the Moessbauer spectra reveals that below 623 K the easy axis of the magnetization is axial-along the wires, and that a tangential or/and radial orientation occurs at higher temperatures. At 770 K, in the first 4 hours the Moessbauer spectrum exhibits a pure paramagnetic doublet. Crystallization and decomposition to predominantly α-Fe(Si) and Fe 2 B occurs either by raising the temperature above 835 K or isothermally in time at lower temperatures. Annealing for a day at 770 K, leads to crystallization. In the crystalline material the magnetic moments have a complete random orientation. After cooling back to ambient temperature, both α-Fe(Si) and Fe 2 B in the glass coated wire show pure axial magnetic orientation like in the original amorphous state. The observed spin reorientations are associated with changes in the stress induced by the glass coating

  10. Paper Punch Tape

    CERN Multimedia

    Physicists coded and recorded their programs through series of holes on punch paper tape or on punched cards. It was popular in the 1970s due to its high throughput speed and low cost, paper tape was one of the original data storage methods for computers. Information was encoded in the distinct pattern of holes punched in the paper; the paper itself was oiled to facilitate being run through the reading mechanism and to prevent tears due to brittleness. Though the paper was cheap, it had low storage capacity (only a few dozen kilobytes per roll) and the machinery involved in punching the holes was quite expensive. Higher capacity alternatives, such as magnetic tape, has get developped.

  11. Improved superconducting magnet wire

    Science.gov (United States)

    Schuller, I.K.; Ketterson, J.B.

    1983-08-16

    This invention is directed to a superconducting tape or wire composed of alternating layers of copper and a niobium-containing superconductor such as niobium of NbTi, Nb/sub 3/Sn or Nb/sub 3/Ge. In general, each layer of the niobium-containing superconductor has a thickness in the range of about 0.05 to 1.5 times its coherence length (which for Nb/sub 3/Si is 41 A) with each copper layer having a thickness in the range of about 170 to 600 A. With the use of very thin layers of the niobium composition having a thickness within the desired range, the critical field (H/sub c/) may be increased by factors of 2 to 4. Also, the thin layers of the superconductor permit the resulting tape or wire to exhibit suitable ductility for winding on a magnet core. These compositions are also characterized by relatively high values of critical temperature and therefore will exhibit a combination of useful properties as superconductors.

  12. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  14. Melt processing of Yb-123 tapes

    International Nuclear Information System (INIS)

    Athur, S. P.; Balachandran, U.; Salama, K.

    2000-01-01

    The innovation of a simple, scalable process for manufacturing long-length conductors of HTS is essential to potential commercial applications such as power cables, magnets, and transformers. In this paper the authors demonstrate that melt processing of Yb-123 tapes made by the PIT route is an alternative to the coated conductor and Bi-2223 PIT tape fabrication techniques. Ag-clad Yb-123 tapes were fabricated by groove rolling and subsequently, melt processed in different oxygen partial pressures in a zone-melting furnace with a gradient of 140 C/cm. The transition temperatures measured were found to be around 81 K undermost processing conditions. EPMA of the tapes processed under different conditions show the 123 phase to be Ba deficient and Cu and Yb rich. Critical current was measured at various temperatures from 77 K to 4.2 K. The J c increased with decrease in pO 2 . The highest I c obtained was 52 A at 4.2 K

  15. Adhesive tape exfoliation

    DEFF Research Database (Denmark)

    Bohr, Jakob

    2015-01-01

    Single-crystal graphite can be cleaved by the use of an adhesive tape. This was also the initial route for obtaining graphene, a one-layer thick graphite slab. In this letter a few simple and fun considerations are presented in an attempt to shed some light on why this procedure is successful...

  16. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  17. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  18. Safety brake for tape reels

    Science.gov (United States)

    Carle, C. E.

    1977-01-01

    All-mechanical device senses end of tape and stops reel, even in event of electronic system failure. Assembly includes stop to prevent brake from overriding tape. Recentering mechanism returns brake to neutral position after torque is removed from reels.

  19. Solderability study of RABiTS-based YBCO coated conductors

    International Nuclear Information System (INIS)

    Zhang Yifei; Duckworth, Robert C.; Ha, Tam T.; Gouge, Michael J.

    2011-01-01

    Study examines the implication of solder and flux selection in YBCO splice joints. Focus is on commercially available RABiTS-based YBCO coated conductors. Solderability varied with solder and flux for three different stabilizations tested. Resistivity of stabilizer was dominant factor in splice joint resistance. Solder materials affected splice joint resistance when solderability was poor. The solderability of commercially available YBa 2 Cu 3 O 7-x (YBCO) coated conductors that were made from Rolling Assisted Biaxially Textured Substrates (RABiTS)-based templates was studied. The coated conductors, also known as second-generation (2G) high temperature superconductor (HTS) wires (in the geometry of flat tapes about 4 mm wide), were laminated with copper, brass, or stainless steel strips as stabilizers. To understand the factors that influence their solderability, surface profilometry and scanning electron microscopy were used to characterize the wire surfaces. The solderability of three solders, 52In48Sn, 67Bi33In, and 100In (wt.%), was evaluated using a standard test (IPC/ECA J-STD-002) and with two different commercial fluxes. It was found that the solderability varied with the solder and flux but the three different wires showed similar solderability for a fixed combination of solder and flux. Solder joints of the 2G wires were fabricated using the tools and the procedures recommended by the HTS wire manufacturer. The solder joints were made in a lap-joint geometry and with the superconducting sides of the two wires face-to-face. The electrical resistances of the solder joints were measured at 77 K, and the results were analyzed to qualify the soldering materials and evaluate the soldering process. It was concluded that although the selection of soldering materials affected the resistance of a solder joint, the resistivity of the stabilizer was the dominant factor.

  20. Modification of critical current in HTSC tape conductors by a ferromagnetic layer

    International Nuclear Information System (INIS)

    Goemoery, F; Souc, J; Seiler, E; Vojenciak, M; Granados, X

    2008-01-01

    In some applications of tape conductors from high temperature superconductors (HTSC) the magnetic field is created by the transported current itself. This is e.g. the case of power transmission cables or current leads. Quite complex distribution of local magnetic field determines then the ability of the superconducting element to carry electrical current. We have investigated how much the critical current of a tape conductor can be changed by putting a ferromagnetic layer in the vicinity of the HTSC material. Numerical procedure has been developed to resolve the current and field distribution in such superconductor-ferromagnet composite tape. Theoretical predictions have been confirmed by experiments on sample made from Bi-2223/Ag composite tape. The critical current of such tape can be improved by placing a soft ferromagnetic material at the tape's edges. On the other hand, the calculations show that the ferromagnetic substrate of YBCO coated tape reduces its self-field critical current

  1. Tamper tape seals

    International Nuclear Information System (INIS)

    Wright, B.W.; Undem, H.A.

    1994-07-01

    Tamper tapes are appealing for many applications due to their ease of use and relative robustness. Applications include seals for temporary area denial, protection of sensitive equipment, chain-of-custody audit trails, and inventory control practices. A next generation of adhesive tamper tapes is being developed that combines the best features of commercially available devices with additional state-of-the-art features in tamper indication, tamper-resistance, and counterfeit-resistance. The additional features are based on U.S. Department of Energy (DOE) research and development (R ampersand D) activities that were originally associated with preparations for the Strategic Arms Reduction Treaty (START). New features include rapid-set, chemical-cure adhesive systems that allow user-friendly application and layered levels of counterfeit-resistance based on unique open-quotes fingerprintclose quotes characteristics that can be accessed as desired

  2. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  4. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  5. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  6. PVC membrane, coated-wire, and carbon-paste ion-selective electrodes for potentiometric determination of galantamine hydrobromide in physiological fluids.

    Science.gov (United States)

    Abdel-Haleem, Fatehy M; Saad, Mohamed; Barhoum, Ahmed; Bechelany, Mikhael; Rizk, Mahmoud S

    2018-08-01

    We report on highly-sensitive ion-selective electrodes (ISEs) for potentiometric determining of galantamine hydrobromide (GB) in physiological fluids. Galantamine hydrobromide (GB) was selected for this study due to its previous medical importance for treating Alzheimer's disease. Three different types of ISEs were investigated: PVC membrane electrode (PVCE), carbon-paste electrode (CPE), and coated-wire electrode (CWE). In the construction of these electrodes, galantaminium-reineckate (GR) ion-pair was used as a sensing species for GB in solutions. The modified carbon-paste electrode (MCPE) was prepared using graphene oxide (MCPE-GO) and sodium tetrakis (trifluoromethyl) phenyl borate (MCPE-STFPB) as ion-exchanger. The potentiometric modified CPEs (MCPE-GO and MCPE-STFPB) show an improved performance in term of Nernstian slope, selectivity, response time, and response stability compared to the unmodified CPE. The prepared electrodes PVCE, CWE, CPE, MCPE-GO and MCPE-STFPB show Nernstian slopes of 59.9, 59.5, 58.1, 58.3 and 57.0 mV/conc. decade, and detection limits of 5.0 × 10 -6 , 6.3 × 10 -6 , 8.0 × 10 -6 , 6.0 × 10 -6 and 8.0 × 10 -6  mol L -1 , respectively. The prepared ISEs also show high selectivity against cations (i.e. Na + , K + , NH 4 + , Ca 2+ , Al 3+ , Fe 3+ ), amino acids (i.e. glycine, L-alanine alanine), and sugars (i.e. fructose, glucose, maltose, lactose). The prepared ISEs are applicable for determining GB in spiked serums, urines, and pharmaceutical preparations, using a standard addition and a direct potentiometric method. The fast response time (<10 s), long lifetime (1-5 weeks), reversibility and stability of the measured signals facilitate the application of these sensors for routine analysis of the real samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  7. Effect of Initial Surface Quality on Final Roughness and Texture of Annealed Ni-5at.%W Tapes Coated with a Gd2Zr2O7 Buffer Layer

    DEFF Research Database (Denmark)

    Wulff, Anders Christian; Yue, Zhao; Mishin, Oleg

    2012-01-01

    Surface roughness of Ni-5at.%W tapes in coldrolled and annealed conditions after subsequent deposition of a Gd2Zr2O7 buffer layer has been studied as a function of the polishing grade, taking grain boundary grooving into account. It is found that annealing decreases the initial mean surface...... roughness achieved by mechanical polishing of the cold-rolled material, except after very fine polishing. Furthermore, compared to the surface of the tape annealed after fine polishing, the mean roughness slightly increases after the deposition of the buffer layer. Grain boundary grooving was found...... to impose a lower limit for the mean surface roughness. In the annealed tapes, the fraction of orientations within 5◦ from the ideal cube orientation was observed to be very sensitive to the surface roughness before annealing....

  8. Possibility of material cost reduction toward development of low-cost second-generation superconducting wires

    Science.gov (United States)

    Ichinose, Ataru; Horii, Shigeru; Doi, Toshiya

    2017-10-01

    Two approaches to reducing the material cost of second-generation superconducting wires are proposed in this paper: (1) instead of the electrical stabilizing layers of silver and copper presently used on the superconducting layer, a Nb-doped SrTiO3 conductive buffer layer and cube-textured Cu are proposed as an advanced architecture, and (2) the use of an electromagnetic (EM) steel tape as a metal substrate of coated conductors in a conventional architecture. In structures fabricated without using electrical stabilizing layers on the superconducting layer, the critical current density achieved at 77 K in a self-field was approximately 2.6 MA/cm2. On the other hand, in the case of using EM steel tapes, although the critical current density was far from practical at the current stage, the biaxial alignment of YBa2Cu3O y (YBCO) and buffer layers was realized without oxidation on the metal surface. In this study, the possibility of material cost reduction has been strongly indicated toward the development of low-cost second-generation superconducting wires in the near future.

  9. Teaching with MARC Tapes

    Directory of Open Access Journals (Sweden)

    Pauline Atherton

    1970-03-01

    Full Text Available A computer based laboratory for library science students to use in class assignments and for independent projects has been developed and used for one year at Syracuse University. MARC Pilot Project tapes formed the data base. Different computer programs and various samples of the MARC file (48,POO records, approx. were used for search and retrieval operations. Data bases, programs, and seven different class assignments are described and evaluated for their impact on library education in gen- eral and individual students and faculty in particular.

  10. Application for the Tape Station

    CERN Document Server

    Solero, A

    2003-01-01

    The Tape Station is used as an Isolde facility to observe the variations of intensity and the lifespan of certain isotopes. A Siemens Simatic FM-352-5 module controls the Tape Station in a PLC system then a DSC controls the PLC, which will be controlled the Tape station program. During the Isolde consolidation project, the Tape Station has been rebuilt, and the control system has been fully integrated in the PS control. Finally, a new application has been written in JAVA Development kit 1.4 and the PS Java environment. The main purpose of this note is to explain how to use this program.

  11. Rapid prototyping of microfluidic systems using a PDMS/polymer tape composite.

    Science.gov (United States)

    Kim, Jungkyu; Surapaneni, Rajesh; Gale, Bruce K

    2009-05-07

    Rapid prototyping of microfluidic systems using a combination of double-sided tape and PDMS (polydimethylsiloxane) is introduced. PDMS is typically difficult to bond using adhesive tapes due to its hydrophobic nature and low surface energy. For this reason, PDMS is not compatible with the xurography method, which uses a knife plotter and various adhesive coated polymer tapes. To solve these problems, a PDMS/tape composite was developed and demonstrated in microfluidic applications. The PDMS/tape composite was created by spinning it to make a thin layer of PDMS over double-sided tape. Then the PDMS/tape composite was patterned to create channels using xurography, and bonded to a PDMS slab. After removing the backing paper from the tape, a complete microfluidic system could be created by placing the construct onto nearly any substrate; including glass, plastic or metal-coated glass/silicon substrates. The bond strength was shown to be sufficient for the pressures that occur in typical microfluidic channels used for chemical or biological analysis. This method was demonstrated in three applications: standard microfluidic channels and reactors, a microfluidic system with an integrated membrane, and an electrochemical biosensor. The PDMS/tape composite rapid prototyping technique provides a fast and cost effective fabrication method and can provide easy integration of microfluidic channels with sensors and other components without the need for a cleanroom facility.

  12. BALLISTIC RESISTANT ARTICLES COMPRISING TAPES

    NARCIS (Netherlands)

    VAN DER EEM, JORIS; HARINGS, JULES; JANSE, GERARDUS; TJADEN, HENDRIK

    2015-01-01

    The invention pertains to a ballistic-resistant moulded article comprising a compressed stack of sheets comprising reinforcing tapes having a tensile strength of at least 1.0 GPa, a tensile modulus of at least 40 GPa, and a tensile energy-to-break of at least 15 J/g, the direction of the tapes

  13. Centrally managed tapes at DESY

    International Nuclear Information System (INIS)

    Hell, O.

    1994-01-01

    Tapes at DESY are managed by the computer center and thus offer virtually unlimited storage space to the DESY computer center users. This paper describes the most recent version of the DESY tape management system, its predecessors having been in service for many years

  14. Percolation modelling for highly aligned polycrystalline superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Rutter, N A; Glowacki, B A; Evetts, J E [Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); IRC in Superconductivity, Madingley Road, Cambridge CB3 0HE (United Kingdom)

    2000-11-01

    Surface and bulk texture measurements have been carried out on highly aligned NiFe tapes, suitable for use as coated conductor substrates. Data from small-area electron backscatter diffraction measurements are compared with those from bulk x-ray analysis in the development of a two-dimensional percolation model, and the two are shown to give very similar results. No evidence of grain-to-grain correlation is found. The model is then developed to assess how the properties of a superconducting layer grown epitaxially on buffered tapes will depend on parameters such as sample size, grain size and the extent of grain alignment. (author)

  15. New concept for a compact tape transport system

    International Nuclear Information System (INIS)

    Mlekodaj, R.L.; Zganjar, E.F.; Cole, J.D.

    1980-01-01

    A new concept in tape transport systems for the collection and counting of radioactive samples from an on-line isotope separator has been developed. This new compact design was motivated by space limitations but important additional improvements over previous designs were made in cost, simplicity and vacuum quality. The system is based on a continuous loop of 6.5 millimeter wide recording tape 116 meters long with a conducting coating on one side for beam current monitoring. One small stepping motor is required for operation

  16. A new concept for a compact tape transport system

    International Nuclear Information System (INIS)

    Mlekodaj, R.L.; Zganjar, E.F.; Cole, J.D.

    1981-01-01

    A new concept in tape transport systems for the collection and counting of radioactive samples from an on-line isotope separator has been developed. This new compact design was motivated by space limitations but important additional improvements over previous designs were made in cost, simplicity and vacuum quality. The system is based on a continuous loop of 6.5 mm wide recording tape 116 m long with a conducting coating on one side for beam current monitoring. One small stepping motor is required for operation. (orig.)

  17. Buffer layers grown by replicating the texture of an original template tape

    International Nuclear Information System (INIS)

    Lim, Sunme; Yoo, Jaeun; Park, Chan; Youm, Dojun

    2007-01-01

    We propose a fabrication method of the buffer layers, whose biaxial textures are replicated from an original template tape. The purpose of this method is economical texturing process for coated conductors. At first we prepared a biaxially textured metal tape (TM-tape). Then a sacrifice layer (SA), a buffer layer (BU) and a thick metallic layer (SM) were sequentially deposited on the TM-tape. SA-layer and BU-layer were deposited epitaxially to copy the texture of the TM-tape. SA-layer was dissoluble in water. SM-layer with the textured BU-layer was separated and could be used for a supporting tape for the further growth of a superconducting layer. In this way, it is possible to reuse the original textured TM-tape many times. In this paper, we report the results of our experiments, in which we used a biaxially Ni tape, BaO film, STO film, and a thick Ag film for TM-tape, SA-layer, BU-layer, and SM-layer, respectively. The Ag/STO layers were successfully separated form the Ni tape by dissolving the BaO layer in water. The texture quality of the STO layer was well secured after the separation

  18. Fabrication and application of mesoporous TiO{sub 2} film coated on Al wire by sol-gel method with EISA

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Linkang; Lu, Jianjun, E-mail: lujianjunktz@tyut.edu.cn

    2017-04-30

    Highlights: • Successfully fabricated mesoporous TiO{sub 2} thin film on Al wire by sol-gel method with EISA. • Ni supported on this film and exhibits good methanation performance. • Investigate the decomposition temperature of template agent F127 in TiO{sub 2} precursor system. - Abstract: Mesoporous TiO{sub 2} film on Al wire was fabricated by sol-gel method with evaporation induced self assembly (EISA) process using F127 as templating agent in the mixed solution of ethanol and Tetra-n-butyl Titanate. The Ni/TiO{sub 2} film catalyst supported on Al wire was prepared by impregnation and the catalytic performance on methanation was carried out in a titanium alloy micro-reactor tube. It was shown that anatase mesoporous TiO{sub 2} film was prepared in this conditions (1 g F127,calcined at 400 °C and aged for 24 h), which has specific surface area of 127 m{sup 2} g{sup −1} and narrow pore size distribution of 5.3 nm. Low calcined temperature (300 °C) cannot transfer film to anatase and decompose F127 completely. Ni/TiO{sub 2} film on Al wire catalyst was proved to be active in CO methanation reaction. And the CO conversion reaches 99% and CH{sub 4} selectivity close is to 80% when the reaction temperature is higher 360 °C.

  19. Processing of flexible high-Tc superconducting wires

    International Nuclear Information System (INIS)

    Lee, B.I.; Modi, V.

    1989-01-01

    Wires superconducting at temperatures above 77 K are produced by using YBa 2 Cu 3 O 7 materials. Flexibility was obtained by support from prefabricated fibers or a metallic coating on the extruded YBa 2 Cu 3 O 7 wires. The microstructure, the T c and the critical current densities of the wires were determined. Processing variables and steps are described

  20. Experimental Investigations of Woven Textile Tape as Strain Sensor

    Science.gov (United States)

    Kannaian, T.; Naveen, V. S.; Muthukumar, N.; Thilagavathi, G.

    2015-10-01

    In this article, a strain sensitive textile based elastomeric tape sensor has been developed and process parameters for sensor development are optimized. Polyester yarns are used as base threads and rubber threads are used as elastomer for the sensor development. The sensor has been developed with the help of narrow width tape loom by introducing the silver coated nylon yarn in the middle of the tape structure. The influence of weave structure, number of conductive threads and rubber thread tension on sensor development has been optimized by using the Box-Behnken method and the results are analyzed using the Design expert software. From the results, it is found that six numbers of conductive threads in a plain weave structure with rubber thread tension of 750 g is suitable for the sensor to give high gauge factor of 1.626.

  1. Enhancement of condensation heat transfer using electric field. Effects of wire-electrode coating; Denba ni yoru gyoshuku netsu dentatsu no sokushin ni kansuru kenkyu. Wire denkyoku no hifuku koka

    Energy Technology Data Exchange (ETDEWEB)

    Chu, R. [Gifu University, Gifu (Japan). Faculty of Enginering; Nishio, S. [The University of Tokyo, Tokyo (Japan). Institute of Industrial Science; Tanasawa, I. [Nihon University, Fukushima (Japan). College of Engineering

    2000-08-25

    In the present paper, an attempt is made to develop an effective EHD enhancement technique for condensation heat transfer of steam around a horizontal finned tube. The main idea in the present study is to reduce the power consumption by using a partially coated electrode, and the experimental data of heat transfer coefficients and flooding angles are presented. The result indicates that, by using such an electrode, the enhancement ratio keeps almost the same level with that of a bare electrode but the power consumption can be markedly decreased. Within the present experimental range, the condensation heat transfer coefficient on the finned tube with the partially coated electrode reaches a value about 3 times larger than that without electrode. In addition, a model in presented for the EHD effect on the flooding angle and it is confirmed that the prediction from the model is in good agreement with the experimental data. (author)

  2. Pacemaker wires

    International Nuclear Information System (INIS)

    Fransson, S.G.

    1993-01-01

    Evaluation of pacemaker wires were performed by comparing Advanced Multiple Beam Equalization Radiography (AMBER) with conventional chest radiography. The scanning equalization technique of the AMBER unit makes it superior to conventional technique in the depiction of different structures in the mediastinum or in the pleural sinuses. So far motion artifacts have not been considered clinically important. The longer exposure time, however, may impair the assessment of pacemaker wires. The motion artifact described may not only make adequate evaluation impossible but may even give a false impression of a lead fracture. The difference between the two systems was significant. (orig.)

  3. Post-heat treatment of arc-sprayed coating prepared by the wires combination of Mg-cathode and Al-anode to form protective intermetallic layers

    International Nuclear Information System (INIS)

    Xu Rongzheng; Song Gang

    2011-01-01

    A Mg-Al intermetallic compounds coating was prepared on the surface of Mg-steel lap joint by arc-sprayed Al-Mg composite coating (Mg-cathode and Al-anode) and its post-heat treatment (PHT). The effect of PHT temperature on the phase transition, microstructure and mechanical properties of the coating was investigated by X-ray diffraction, scanning electron microscope, energy dispersive X-ray spectroscopy, optical microscope and microhardness test. The result shows that the intermetallic compounds layer that is mainly composed of Al 3 Mg 2 and Mg 17 Al 12 is formed by the self-diffusion reaction of Mg and Al splats in the coating after PHT for 4 h at 430 deg. C.

  4. Experiment of enhancing critical current in Bi-2223/Ag tape by means of ferromagnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Alamgir, A.K.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)]. E-mail: alam643@hotmail.com; Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)

    2005-11-15

    Critical current in multifilamentary Ag-sheath Bi-2223 tape is enhanced to some extent by means of thin and narrow coating of pure nickel. The concept of enhancing critical current is based on the magnetic shielding effect resulting in redirection of self-field flux lines. The Ni coating was introduced at the edge regime of the tape in order to redirect the perpendicular component of self-field lines which is severe at the edges. Critical current in a typical Ag-sheath Bi-2223 tape was enhanced up to {approx}11% by 50 {mu}m thick and 0.4 mm long Ni coating without any change of self-field loss. This fact reveals that additional ferromagnetic loss could be compensated by the shielding effect and increased critical current of the tape. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the length and thickness of ferromagnetic coating introduced. Therefore, it is very important to control the geometry of ferromagnetic coating in order to balance the critical current and ac loss for optimum superconductor performance. Introduction of ferromagnetic coating and its effect on electromagnetic properties in multifilamentary Bi-2223/Ag tape will be reported in this article.

  5. Experiment of enhancing critical current in Bi-2223/Ag tape by means of ferromagnetic shielding

    International Nuclear Information System (INIS)

    Alamgir, A.K.M.; Gu, C.; Han, Z.

    2005-01-01

    Critical current in multifilamentary Ag-sheath Bi-2223 tape is enhanced to some extent by means of thin and narrow coating of pure nickel. The concept of enhancing critical current is based on the magnetic shielding effect resulting in redirection of self-field flux lines. The Ni coating was introduced at the edge regime of the tape in order to redirect the perpendicular component of self-field lines which is severe at the edges. Critical current in a typical Ag-sheath Bi-2223 tape was enhanced up to ∼11% by 50 μm thick and 0.4 mm long Ni coating without any change of self-field loss. This fact reveals that additional ferromagnetic loss could be compensated by the shielding effect and increased critical current of the tape. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the length and thickness of ferromagnetic coating introduced. Therefore, it is very important to control the geometry of ferromagnetic coating in order to balance the critical current and ac loss for optimum superconductor performance. Introduction of ferromagnetic coating and its effect on electromagnetic properties in multifilamentary Bi-2223/Ag tape will be reported in this article

  6. Asteroid Composite Tape

    Science.gov (United States)

    1998-07-01

    This is a composite tape showing 10 short segments primarily about asteroids. The segments have short introductory slides, which include brief descriptions about the shots. The segments are: (1) Radar movie of asteroid 1620 Geographos; (2) Animation of the trajectories of Toutatis and Earth (3) Animation of a landing on Toutatis; (4) Simulated encounter of an asteroid with Earth, includes a simulated impact trajectory; (5) An animated overview of the Manrover vehicle; (6) The Near Earth Asteroid Tracking project, includes a photograph of USAF Station in Hawaii, and animation of Earth approaching 4179 Toutatis and the asteroid Gaspara; (7) live video of the anchor tests of the Champoleon anchoring apparatus; (8) a second live video of the Champoleon anchor tests showing anchoring spikes, and collision rings; (9) An animated segment with narration about the Stardust mission with sound, which describes the mission to fly close to a comet, and capture cometary material for return to Earth; (10) live video of the drop test of a Stardust replica from a hot air balloon; this includes sound but is not narrated.

  7. A viable dipole magnet concept with REBCO CORC® wires and further development needs for high-field magnet applications

    Science.gov (United States)

    Wang, Xiaorong; Caspi, Shlomo; Dietderich, Daniel R.; Ghiorso, William B.; Gourlay, Stephen A.; Higley, Hugh C.; Lin, Andy; Prestemon, Soren O.; van der Laan, Danko; Weiss, Jeremy D.

    2018-04-01

    REBCO coated conductors maintain a high engineering current density above 16 T at 4.2 K. That fact will significantly impact markets of various magnet applications including high-field magnets for high-energy physics and fusion reactors. One of the main challenges for the high-field accelerator magnet is the use of multi-tape REBCO cables with high engineering current density in magnet development. Several approaches developing high-field accelerator magnets using REBCO cables are demonstrated. In this paper, we introduce an alternative concept based on the canted cos θ (CCT) magnet design using conductor on round core (CORC®) wires that are wound from multiple REBCO tapes with a Cu core. We report the development and test of double-layer three-turn CCT dipole magnets using CORC® wires at 77 and 4.2 K. The scalability of the CCT design allowed us to effectively develop and demonstrate important magnet technology features such as coil design, winding, joints and testing with minimum conductor lengths. The test results showed that the CCT dipole magnet using CORC® wires was a viable option in developing a REBCO accelerator magnet. One of the critical development needs is to increase the engineering current density of the 3.7 mm diameter CORC® wire to 540 A mm-2 at 21 T, 4.2 K and to reduce the bending radius to 15 mm. This would enable a compact REBCO dipole insert magnet to generate a 5 T field in a background field of 16 T at 4.2 K.

  8. Living Wires - Effects of Size and Coating of Gold Nanoparticles in Altering the Electrical Properties of Physarum polycephalum and Lettuce Seedlings

    OpenAIRE

    Gizzie, Nina; Mayne, Richard; Yitzchaik, Shlomo; Ikbal, Muhamad; Adamatzky, Andrew

    2015-01-01

    The manipulation of biological substrates is becoming more popular route towards generating novel computing devices. Physarum polycephalum is used as a model organism in biocomputing because it can create `wires' for use in hybrid circuits; programmable growth by manipulation through external stimuli and the ability withstanding a current and its tolerance to hybridisation with a variety of nano/microparticles. Lettuce seedlings have also had previous interest invested in them for generating ...

  9. String and Sticky Tape Experiments.

    Science.gov (United States)

    Edge, R. D., Ed.

    1979-01-01

    Explains how to demonstrate the fundamentals of one dimensional kinematics such as Newton's third law of motion, and collision between bodies, using simple materials of marbles, strings, sticky tape, drinking straws, and rubber bands. (GA)

  10. Tape casting fluorinated YBC123

    International Nuclear Information System (INIS)

    Taylor, J.A.T.; Luke, D.M.; Whiteley, B.A.

    1991-01-01

    Tape casting the superconducting Ba-Y-Cu oxide was accomplished by several laboratories and show promise for being a versatile forming technique. The major problem is low current density, probably due to lack of grain alignment and grain boundary related weak links. The latter problem may be due to formation of carbonates and hydroxides during binder burnout. Preliminary work done at Alfred shows that a bimodal powder size distribution displays significant alignment after tape casting and that F treated powder is resistant to attack by steam at 100C. Such corrosion resistant powder cast as form tape should survive the binder burnout without the detrimental grain boundary phases that develop from reaction of the superconducting phase, steam and carbon dioxide. This paper presents the results of an investigation of tape casting fluorinated powder with a bimodal size distribution

  11. Tape Storage and CRC Protection

    CERN Document Server

    Ha, Karel

    2014-01-01

    Over 100 Petabytes of data is stored on several kind of physical support, namely disks and tapes. Data on any physical support or traveling on a data link (network, fibre channel...) can be subject to silent data corruption. A possible improvement is introducing end-to-end data integrity from the filesystem down to the tape layer. For the tape back-end it can be done by using Logical Block Protection, which computes and compares CRC checksum of every single block of data. During my work, I improved on-the-fly CRC calculation for the tape storage system, which was achieved by introducing a multithreaded implementation - a technique applicable to arbitrary CRC algorithm. Finally, I per...

  12. Accelerated aging studies and environmental stability of prototype tamper tapes

    Energy Technology Data Exchange (ETDEWEB)

    Wright, B.W.; Wright, C.W. [Pacific Northwest Lab., Richland, WA (United States); Bunk, A.R. [Battelle Columbus Lab., OH (United States)] [and others

    1995-05-01

    This report describes the results of accelerated aging experiments (weathering) conducted on prototype tamper tapes bonded to a variety of surface materials. The prototype tamper tapes were based on the patented Confirm{reg_sign} tamper-indicating technology developed and produced by 3M Company. Tamper tapes bonded to surfaces using pressure sensitive adhesive (PSA) and four rapid-set adhesives were evaluated. The configurations of the PSA-bonded tamper tapes were 1.27-cm-wide Confirm{reg_sign} 1700 windows with vinyl underlay and 2.54-cm-wide Confirm{reg_sign} 1700 windows with vinyl and polyester underlays. The configurations of the rapid-set adhesive-bonded tamper tapes were 2.54-cm-wide Confirm{reg_sign} (1700, 1500 with and without primer, and 1300) windows with vinyl underlay. Surfaces used for bonding included aluminum, steel, stainless steel, Kevlar{reg_sign}, brass, copper, fiberglass/resin with and without gel coat, polyurethane-painted steel, acrylonitrile:butadiene:styrene plastic, polyester fiberglass board, Lexan polycarbonate, and cedar wood. Weathering conditions included a QUV cabinet (ultraviolet light at 60{degrees}C, condensing humidity at 40{degrees}C), a thermal cycling cabinet (-18{degrees}C to 46{degrees}C), a Weather-O-Meter (Xenon lamp), and exposure outdoors in Daytona Beach, Florida. Environmental aging exposures lasted from 7 weeks to 5 months. After exposure, the tamper tapes were visually examined and tested for transfer resistance. Tamper tapes were also exposed to a variety of chemical liquids (including organic solvents, acids, bases, and oxidizing liquids) to determine chemical resistance and to sand to determine abrasion resistance.

  13. Investigation of method for Stainless Steel Welding Wire as a Replacement for Arc Wire Comsumables

    Directory of Open Access Journals (Sweden)

    Koiprasert, H.

    2005-01-01

    Full Text Available Arc spraying as a coating method is being employed in various industrial applications as a part of maintenance service, and also as a surface engineering technique for many machine parts and components. The major cost in producing the arc spray coating is, however, based on the cost of the arc wire comsumables. This project was carried out to investigate the use of the commercially-available gas metal arc welding wire (GMAW wire as a cheaper alternative to the special-purpose arc wire comsumables. The wire material chosen for this early study is the 316L stainless steel, due to its popularity in many applications as a built-up coating for worn parts. The physical properties of the coatings produced from the two sets of 316L stainless steel wire were determined to be different in the percentage of porosity and the oxide content. The mechanical properties, including the tensile bond strength and the wear rate of the coatings produced from the two types of sprayed wire, were also different. This will, in turn, result in a slight difference in the performance of thecoatings.

  14. Experiments and FE modeling of stress-strain state in ReBCO tape under tensile, torsional and transverse load

    NARCIS (Netherlands)

    Ilin, K.; Ilin, K.; Yagotyntsev, Kostyantyn; Zhou, Chao; Gao, Peng; Kosse, Jaap Jeroen; Otten, S.J.; Wessel, Wilhelm A.J.; Haugan, T.J.; van der Laan, D.C.; Nijhuis, Arend

    2015-01-01

    For high current superconductors in high magnet fields with currents in the order of 50 kA, single ReBCO coated conductors must be assembled in a cable. The geometry of such a cable is mostly such that combined torsion, axial and transverse loading states are anticipated in the tapes and tape

  15. New developments for the investigation of hard X-rays emitted by peeling adhesive tapes.

    Science.gov (United States)

    Krämer, D; Lützenkirchen-Hecht, D; Lühmann, B; Keite-Telgenbüscher, K; Frahm, R

    2013-05-01

    We realized an advanced apparatus for the investigation of emitted X-rays produced by peeling adhesive tape rolls under vacuum conditions. Two stepper motors can unwind and rewind a tape roll, and an additional roller with an optical encoder provides measurement and control of the tape speed. This way reproducible and consecutive experiments are feasible without having to change the tape or break the vacuum. The dependence of the X-ray emission on tape speed, gas pressure, type of adhesive tape, and detector angle has been investigated. The resulting spectra are continuous and span an X-ray energy range of typically 2-60 keV with high intensity. Furthermore, the new apparatus allows the in situ metalization of adhesive tape rolls by a gold sputter source. A significantly increased X-ray emission was observed for adhesive tapes with a metal coating. Thin metal foils have been placed between the tape and the detector, different K- and L-absorption edges could be measured. A considerable enhancement of the emission was achieved under the influence of the magnetic field of an NdFeB permanent magnet.

  16. Lunar Module Wiring Design Considerations and Failure Modes

    Science.gov (United States)

    Interbartolo, Michael

    2009-01-01

    This slide presentation reviews the considerations for the design of wiring for the Lunar Module. Included are a review of the choice of conductors and insulations, the wire splicing (i.e., crimping, and soldering), the wire connectors, and the fabrication of the wire harnesses. The problems in fabrication include the wires being the wrong length, the damage due to the sharp edges, the requried use of temproary protective covers and inadequate training. The problems in the wire harness installation include damge from sharp eges, work on adjacent harnesses, connector damage, and breaking wires. Engineering suggestions from the Apollo-era in reference to the conductors that are reviewed include: the use of plated conductors, and the use of alloys for stronger wiring. In refernce to insulation, the suggestions from Apollo era include the use of polymer tape-wrap wire insulation due to the light weight, however, other types of modern insulation might be more cost-effective. In reference to wire splices and terminal boards the suggestions from the Apollo Era include the use of crimp splices as superior to solder splices, joining multiple wire to a common point using modular plug-ins might be more reliable, but are heavier than crimp splicing. For connectors, the lessons from the Apollo era indicate that a rear environmental seal that does not require additional potting is preferred, and pins should be crimped or welded to the incoming wires and be removable from the rear of the connector.

  17. YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} coated conductor deposited onto non-magnetic ternary alloy NiCrW RABiTS tape by in situ pulsed laser deposition

    Energy Technology Data Exchange (ETDEWEB)

    Tomov, R I; Kursumovic, A; Majoros, M; Glowacki, B A; Evetts, J E; Tuissi, A; Villa, E; Zamboni, M; Sun, Y; Toenies, S; Weber, H W

    2003-01-01

    Pulsed laser deposition of YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (YBCO)/buffer (Y{sub 2}O{sub 3}, YSZ, CeO{sub 2}) heterostructures have been performed in situ onto recently developed non-magnetic oxygenation resistant NiCrW tape. The influence of the critical processing parameters on texture development are investigated and the issues involved in NiO formation and relation to the substrate surface quality are discussed. The roles of Ni poisoning YBCO as well as local cation disorder are considered as possible current limiting factors. X-ray diffraction has been used for macro-texture evaluation. Both buffers and YBCO layers show good biaxial alignment with {omega} and {phi} scans having best YBCO FWHM values of 4.0 deg. and 6.5 deg. respectively. A comparison is made with results achieved on industrial Ni{sub 50}Fe{sub 50} tape. The film morphology has been characterized using atomic force microscopy and scanning electron microscopy. The cation disorder has been studied by Raman spectroscopy. Critical temperatures of 90 K ({delta}T{sub c}=5 K) have been measured. Direct transport as well as magnetic measurements shows the critical current density J{sub c} is 0.2 MA/cm{sup 2} in self-field at liquid nitrogen temperatures.

  18. Design study of superconducting sextupole magnet using HTS coated conductor for neutron-focusing device

    International Nuclear Information System (INIS)

    Tosaka, T.; Koyanagi, K.; Ono, M.; Kuriyama, T.; Watanabe, I.; Tsuchiya, K.; Suzuki, J.; Adachi, T.; Shimizu, H.M.

    2006-01-01

    We performed a design study of sextupole magnet using high temperature superconducting (HTS) wires. The sextupole magnet is used as a focusing lens for neutron-focusing devices. A neutron-focusing device is desired to have a large aperture and a high magnetic field gradient of G, where G = 2B/r 2 , B is the magnetic field and r is a distance from the sextupole magnet axis. Superconducting magnets offer promising prospects to meet the demands of a neutron-focusing device. Recently NbTi coils of low temperature superconducting (LTS) have been developed for a sextupole magnet with a 46.8 mm aperture. The maximum magnetic field gradient G of this magnet is 9480 T/m 2 at 4.2 K and 12,800 T/m 2 at 1.8 K. On the other hand, rapid progress on second generation HTS wire has been made in increasing the performance of critical current and in demonstrating a long length. The second generation HTS wire is referred to as coated conductor. It consists of tape-shaped base upon which a thin coating of superconductor, usually YBCO, is deposited or grown. This paper describes a design study of sextupole magnet using coated conductors

  19. buffer Layer Growth, the Thickness Dependence of Jc in Coated Conductors, Local Identification of Current Limiting Mechanisms and Participation in the Wire Development Group

    Energy Technology Data Exchange (ETDEWEB)

    Larbalestier, David; Hellstron, Eric; Abraimov, Dmytro

    2011-12-17

    The primary thrusts of our work were to provide critical understanding of how best to enhance the current-carrying capacity of coated conductors. These include the deconstruction of Jc as a function of fim thickness, the growth of in situ films incorporating strong pinning centers and the use of a suite of position-sensitive tools that enable location and analysis of key areas where current-limiting occurs.

  20. Towards the practical PLD-IBAD coated conductor fabrication - Long wire, high production rate and J c enhancement in a magnetic field

    International Nuclear Information System (INIS)

    Yamada, Yutaka; Ibi, Akira; Fukushima, Hiroyuki; Kuriki, Reiji; Miyata, Seiki; Takahashi, Kazuhiro; Kobayashi, Hirokazu; Ishida, Satoru; Konishi, Masaya; Kato, Takeharu; Hirayama, Tsukasa; Shiohara, Yuh

    2006-01-01

    SRL-Nagoya Coated Conductor Center (NCCC) have succeeded in fabricating stably long coated conductor using ion-beam assisted deposition (IBAD) and pulsed laser deposition (PLD) methods. Reel-to-reel PLD equipment with a multi-plume and multi-turn deposition system (MPMT PLD) resulted in a long coated conductor with a high critical current, I c , of 245 A and length of 212.6 m. I c x L (length) reached the record of 52,087 A m. At the same time, the effort to enhance I c and J c in a magnetic filed are also carried out using artificial pinning center and RE element: YSZ mixed Y123 target brought about a high J c especially in the magnetic field parallel to the c-axis. This was attributed to a columnar structure of the 'bamboo structure' (BaZrO 3 /Y123 layer-stacked structure) in Y123 + YSZ sample. Gd123 was also found to be effective for enhancing pinning properties, which was considered to be due to the native stacking faults in the 123 structure. The combination of Gd element and YSZ introduction were also studied and clearly demonstrated the improvement of the anisotropy of J c for a magnetic field angle

  1. Evaluation of a new method for chemical coating of aluminum wire with molecularly imprinted polymer layer. Application for the fabrication of triazines selective solid-phase microextraction fiber

    Energy Technology Data Exchange (ETDEWEB)

    Djozan, Djavanshir, E-mail: djozan@tabrizu.ac.ir [Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of); Ebrahimi, Bahram [Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of); Mahkam, Mehrdad [Chemistry Department, Azarbaijan University of Tarbiat Moallem, Tabriz (Iran, Islamic Republic of); Farajzadeh, Mir Ali [Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz (Iran, Islamic Republic of)

    2010-07-26

    A new solid-phase microextraction (SPME) fiber is fabricated through ultra violet irradiation polymerization of ametryn-molecularly imprinted polymer on the surface of anodized-silylated aluminum wire. The prepared fiber is durable with very good chemical and thermal stability which can be coupled to GC and GC/MS. The effective parameters on the fabrication and application procedures such as spraying mode, ultra violet irradiation (polymerization) time, number of sprayings and polymerizations, pH and ionic strength of sample and extraction time were optimized. This fiber shows high selectivity with great extraction capacity toward triazines. SPME and GC analysis of ametryn, prometryn, terbutryn, atrazine, simazine, propazine and cyanazine using the fabricated fiber result in the detection limits of 9, 32, 27, 43, 51, 74 and 85 ng mL{sup -1}, respectively. The reliability of the prepared fiber in real samples has been investigated and proved by using spiked tap water, rice, maize and onion samples.

  2. Evaluation of a new method for chemical coating of aluminum wire with molecularly imprinted polymer layer. Application for the fabrication of triazines selective solid-phase microextraction fiber

    International Nuclear Information System (INIS)

    Djozan, Djavanshir; Ebrahimi, Bahram; Mahkam, Mehrdad; Farajzadeh, Mir Ali

    2010-01-01

    A new solid-phase microextraction (SPME) fiber is fabricated through ultra violet irradiation polymerization of ametryn-molecularly imprinted polymer on the surface of anodized-silylated aluminum wire. The prepared fiber is durable with very good chemical and thermal stability which can be coupled to GC and GC/MS. The effective parameters on the fabrication and application procedures such as spraying mode, ultra violet irradiation (polymerization) time, number of sprayings and polymerizations, pH and ionic strength of sample and extraction time were optimized. This fiber shows high selectivity with great extraction capacity toward triazines. SPME and GC analysis of ametryn, prometryn, terbutryn, atrazine, simazine, propazine and cyanazine using the fabricated fiber result in the detection limits of 9, 32, 27, 43, 51, 74 and 85 ng mL -1 , respectively. The reliability of the prepared fiber in real samples has been investigated and proved by using spiked tap water, rice, maize and onion samples.

  3. Superconducting flat tape cable magnet

    Science.gov (United States)

    Takayasu, Makoto

    2015-08-11

    A method for winding a coil magnet with the stacked tape cables, and a coil so wound. The winding process is controlled and various shape coils can be wound by twisting about the longitudinal axis of the cable and bending following the easy bend direction during winding, so that sharp local bending can be obtained by adjusting the twist pitch. Stack-tape cable is twisted while being wound, instead of being twisted in a straight configuration and then wound. In certain embodiments, the straight length should be half of the cable twist-pitch or a multiple of it.

  4. Tape write-efficiency improvements in CASTOR

    International Nuclear Information System (INIS)

    Murray, S; Bahyl, V; Cancio, G; Cano, E; Lo Presti, G; Lo Re, G; Ponce, S; Kotlyar, V

    2012-01-01

    The CERN Advanced STORage manager (CASTOR) is used to archive to tape the physics data of past and present physics experiments. For reasons of physical storage space, all of the tape resident data in CASTOR are repacked onto higher density tapes approximately every two years. Improving the performance of writing files smaller than 2GB to tape is essential in order to keep the time needed to repack all of the tape resident data within a period of no more than 1 year. This paper reports on the solution to writing efficiently to tape that is currently in its early deployment phases at CERN.

  5. Tape edge study in a linear tape drive with single-flanged guides

    International Nuclear Information System (INIS)

    Goldade, A.V.; Bhushan, Bharat

    2004-01-01

    Improved tape guiding and tape dimensional stability are essential for magnetic tape linear recoding formats to take advantage of vastly increased track density and thereby achieve higher storage capacities. Tape guiding is dependent on numerous parameters, such as type of the guides and tape path geometry, quality of virgin tape edge, drive operating parameters (e.g., tape speed and tape tension), mechanical properties of the tape, and tape geometry (e.g., cupping and curvature). The objective of the present study is to evaluate guiding and tribological performance of single-flanged guides with porous air bearings in a linear tape drive. A comparison of guiding performance of the dual flanged stationary guides and single-flanged guides with porous air bearings is performed. The effect of tape path geometry, drive operating conditions (speed and tension) and tape edge quality of factory-slit tapes on tape guiding are evaluated during short-term tests. A lateral force measurement technique is used to measure the force exerted by the tape edge on the guide flange. A technique for the lateral tape motion measurement is used to study the effect of continuous sliding on tape guiding. Wear tests up to 5000 cycles are conducted and coefficient of friction and lateral tape motion are monitored to study the effect of drive operating conditions (speed and tension), edge quality of factory-slit tapes and tape thickness on tape guiding. Optical microscopy, atomic force microscopy and scanning electron microscopy are employed to study and quantify the quality of tape edge

  6. Method of preparing composite superconducting wire

    International Nuclear Information System (INIS)

    Verhoeven, J. D.; Finnemore, D. K.; Gibson, E. D.; Ostenson, J. E.; Schmidt, F. A.

    1985-01-01

    An improved method of preparing composite multifilament superconducting wire of Nb 3 Sn in a copper matrix which eliminates the necessity of coating the drawn wire with tin. A generalized cylindrical billet of an alloy of copper containing at least 15 weight percent niobium, present in the copper as discrete, randomly distributed and oriented dendritic-shaped particles, is provided with at least one longitudinal opening which is filled with tin to form a composite drawing rod. The drawing rod is then drawn to form a ductile composite multifilament wire containing a filament of tin. The ductile wire containing the tin can then be wound into magnet coils or other devices before heating to diffuse the tin through the wire to react with the niobium forming Nb 3 Sn. Also described is an improved method for making large billets of the copper-niobium alloy by consumable-arc casting

  7. Application of irradiated wire

    International Nuclear Information System (INIS)

    Uda, I.; Kozima, K.; Suzuki, S.; Tada, S.; Torisu, S.; Veno, K.

    1984-01-01

    Rubber insulated wires are still useful for internal wiring in motor vehicles and electrical equipment because of flexibility and toughness. Irradiated cross-linked rubber materials have been successfully introduced for use with fusible link wire and helically coiled cord

  8. Urinary incontinence - tension-free vaginal tape

    Science.gov (United States)

    ... ency/article/007377.htm Urinary incontinence - tension-free vaginal tape To use the sharing features on this page, please enable JavaScript. Placement of tension-free vaginal tape is surgery to help control stress urinary ...

  9. Noncontextual Wirings

    Science.gov (United States)

    Amaral, Barbara; Cabello, Adán; Cunha, Marcelo Terra; Aolita, Leandro

    2018-03-01

    Contextuality is a fundamental feature of quantum theory necessary for certain models of quantum computation and communication. Serious steps have therefore been taken towards a formal framework for contextuality as an operational resource. However, the main ingredient of a resource theory—a concrete, explicit form of free operations of contextuality—was still missing. Here we provide such a component by introducing noncontextual wirings: a class of contextuality-free operations with a clear operational interpretation and a friendly parametrization. We characterize them completely for general black-box measurement devices with arbitrarily many inputs and outputs. As applications, we show that the relative entropy of contextuality is a contextuality monotone and that maximally contextual boxes that serve as contextuality bits exist for a broad class of scenarios. Our results complete a unified resource-theoretic framework for contextuality and Bell nonlocality.

  10. Development of Bi-based high critical current density superconducting tapes

    International Nuclear Information System (INIS)

    Swaminathan, G.

    1995-01-01

    In order to achieve the aim of developing suitable superconducting materials the main emphasis has to be made in the following areas viz., synthesizing powders, detailed study of sintering and phase conversion process in relation to the critical current density (J c ) on pellets and optimising of tape processing parameters. The bismuth system has been found to be more favourable for making wires and tapes because of its high transition temperature, good stability, does not require oxygen on cooling and is non-toxic. These have been the most convenient properties which made the BiSCO material the most popular one

  11. Effects of ankle eversion taping using kinesiology tape in a patient with ankle inversion sprain

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2016-01-01

    [Purpose] The aim of this study was to report the effects of ankle eversion taping using kinesiology tape on ankle inversion sprain. [Subject] The subject was a 21-year-old woman with Grade 2 ankle inversion sprain. [Methods] Ankle eversion taping was applied to the sprained left ankle using kinesiology tape for 4 weeks (average, 15?h/day). [Results] Ankle instability and pain were reduced, and functional dynamic balance was improved after ankle eversion taping for 4 weeks. The Cumberland Ank...

  12. Analisis Perilaku Konsumen Proll Tape di Jember

    OpenAIRE

    Kusmiati, Ati; Widjayanti, Lenny; Risaldi, Feri

    2009-01-01

    Proll tape is a agroindustrial product which used agriculture product as a basic material. It is a diversification product from tape and mixed with some flavour. It can be found in the gift store. Proll tape marketing strategic will influence consumer behaviour in the decision buying. Consumer buy proll tape as a gift as beside on their own consumption. Consumer considers proll tape has a good quality so that it can fill consumer needed. Purpose of the research to find out the influence facto...

  13. Inorganic Nanostructured High-Temperature Magnet Wires, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will develop a high-temperature tolerant electrically-insulating coating for magnet wires. The Phase I program will result in a flexible, inorganic...

  14. Visualization of latent fingerprints beneath opaque electrical tapes by optical coherence tomography

    Science.gov (United States)

    Liu, Kangkang; Zhang, Ning; Meng, Li; Li, Zhigang; Xu, Xiaojing

    2018-03-01

    Electrical tape is found as one type of important trace evidence in crime scene. For example, it is very frequently used to insulate wires in explosive devices in many criminal cases. The fingerprints of the suspects were often left on the adhesive side of the tapes, which can provide very useful clues for the investigation and make it possible for individual identification. The most commonly used method to detect and visualize those latent fingerprints is to peel off each layer of the tapes first and then adopt the chemical methods to develop the fingerprints on the tapes. However, the peeling-off and chemical development process would degrade and contaminate the fingerprints and thus adversely affect the accuracy of identification. Optical coherence tomography (OCT) is a novel forensic imaging modality based on lowcoherence interferometry, which has the advantages of non-destruction, micrometer-level high resolution and crosssectional imaging. In this study, a fiber-based spectral-domain OCT (SD-OCT) system with {6μm resolution was employed to obtain the image of fingerprint sandwiched between two opaque electrical tapes without any pre-processing procedure like peeling-off. Three-dimensional (3D) OCT reconstruction was performed and the subsurface image was produced to visualize the latent fingerprints. The results demonstrate that OCT is a promising tool for recovering the latent fingerprints hidden beneath opaque electrical tape non-destructively and rapidly.

  15. Pinning Mechanisms in YBCO Tapes

    CERN Document Server

    Spera, Marcello; Ballarino, Amalia

    2015-01-01

    In this thesis work, a study on flux pinning mechanisms of commercial YBCO tapes is presented. This study has been performed via critical current characterization using transport (via direct I-V curves) and magnetization (via a Vibrating Sample Magnetometer) measurements. The latter ones turned out to be better concerning the comprehension of the pinning landscape of the provided samples, as a wider range of magnetic fields and temperatures is available for those measurements in the setup I used. The comparison of the experimental data with existing theoretical models allowed me to draw a picture of the pinning mechanisms underlying in each sample, and they turned out to be quite different one another. Moreover, for high-performance research tapes, another interesting feature has been found: the counterplay between the self-field critical current and the in-field one. Very well engineered artificial pinning structures limit the self-field critical current density due to the hi...

  16. Digital tape unit test facility software

    Science.gov (United States)

    Jackson, J. T.

    1971-01-01

    Two computer programs are described which are used for the collection and analysis of data from the digital tape unit test facility (DTUTF). The data are the recorded results of skew tests made on magnetic digital tapes which are used on computers as input/output media. The results of each tape test are keypunched onto an 80 column computer card. The format of the card is checked and the card image is stored on a master summary tape via the DTUTF card checking and tape updating system. The master summary tape containing the results of all the tape tests is then used for analysis as input to the DTUTF histogram generating system which produces a histogram of skew vs. date for selected data, followed by some statistical analysis of the data.

  17. The neutron beam users tape management system

    International Nuclear Information System (INIS)

    Lyall, B.; Johnson, M.W.

    1977-02-01

    Systems are described for dealing with data collected at the High Flux Reactor, Institut Laue-Langevin, Grenoble and brought on magnetic tape to the Neutron Beam Research Unit at the Rutherford Laboratory. The first system, named GNAT, was designed to archive the incoming 800 bpi tapes onto 6250 bpi tapes (to enable them to return to the ILL). The archiving program, besides choosing the archive tapes, keeping a record of the data sets archived, and writing the archive tape, should be able to cope with incoming tapes whose formats are somewhat different from the standard IBM format. The second system, named FONT, was designed to maintain a record of all the tapes in the NBRU's possession, their whereabouts and what data, if any, are on them. (U.K.)

  18. Research and development efforts relative to superconducting materials. Final report. [Nb/sub 3/Sn tapes

    Energy Technology Data Exchange (ETDEWEB)

    Adam, E; Beishcher, P; Marancik, W; Lucariello, R; Young, M

    1976-04-01

    Three processes for the production of low-loss superconducting tapes of Nb/sub 3/Sn were investigated. They are the rolled-bronze process, the electron beam (EB) bronze deposition process, and the high-rate sputtering process. Shortly after the start of the investigation, effort on the last two processes was suspended because the process-development time that would be needed to arrive at a suitable transmission-line tape appeared most likely to be the shortest with the rolled-bronze process. Long lengths of Nb/sub 3/Sn tapes were prepared by the rolled-bronze process from extruded and rolled bronze-clad niobium billets. Tapes were stabilized by removing the bronze layer after reaction and then coating the exposed Nb/sub 3/Sn with high-purity copper by EB evaporation. Several meters of high quality Nb/sub 3/Sn tapes were produced by the rolled-bronze process. Even when the tapes were stabilized with copper, the losses were as low as 1.8 ..mu..W/cm/sup 2/ at 4.2 K and a surface current density of 500 rms A/cm. Despite early curtailment of the effort on the EB bronze-deposition process, short samples of Nb/sub 3/Sn tapes were produced.

  19. Fabrication of high edge-definition steel-tape gratings for optical encoders

    Science.gov (United States)

    Ye, Guoyong; Liu, Hongzhong; Yan, Jiawei; Ban, Yaowen; Fan, Shanjin; Shi, Yongsheng; Yin, Lei

    2017-10-01

    High edge definition of a scale grating is the basic prerequisite for high measurement accuracy of optical encoders. This paper presents a novel fabrication method of steel tape gratings using graphene oxide nanoparticles as anti-reflective grating strips. Roll-to-roll nanoimprint lithography is adopted to manufacture the steel tape with hydrophobic and hydrophilic pattern arrays. Self-assembly technology is employed to obtain anti-reflective grating strips by depositing the graphene oxide nanoparticles on hydrophobic regions. A thin SiO2 coating is deposited on the grating to protect the grating strips. Experimental results confirm that the proposed fabrication process enables a higher edge definition in making steel-tape gratings, and the new steel tape gratings offer better performance than conventional gratings.

  20. Cutting bubbles with a single wire

    NARCIS (Netherlands)

    Baltussen, M.W.; Segers, Q.I.E.; Kuipers, J.A.M.; Deen, N.G.

    2017-01-01

    Many gas-liquid-solid contactors, such as trickle bed and bubble slurry columns, suffer from heat and mass transfer limitations. To overcome these limitations, new micro-structured bubble column reactor is proposed. In this reactor, a catalyst coated wire mesh is introduced in a bubble column to cut

  1. How to make sticky tapes stickier

    Science.gov (United States)

    Ponson, Laurent; Xia, Shuman; Ravichandran, Guruswami; Bhattacharya, Kaushik; California Institute of Technology Team

    2011-03-01

    Thin film adhesives have become increasingly important in various applications such as packaging and coating, and we benefit daily of their adhesion properties by using various kinds of tapes. Despite the apparent simplicity of these systems, a certain number of questions remain open. In particular, important efforts have been deployed recently to understand the effect of the complex tridimensional and highly heterogeneous structure at the interface of some adhesives, such as the one encountered in nature like the geckos toes. Although inspired by these natural adhesives, we studied a much simpler system, and however largely unexplored: a thin film with spatially varying adhesion energy and elastic properties. We will show how these heterogeneities introduced at the microscale can generate quite unexpected macroscopic behaviors, and that one can this way design stronger adhesives with new properties. Beyond their practical interests, these systems involve long range elastic interactions and heterogeneities resulting in a rich and complex physics that will be illustrated through experimental examples and their theoretical interpretation.

  2. Wire breakage in SLC wire profile monitors

    International Nuclear Information System (INIS)

    Field, C.; McCormick, D.; Raimondi, P.; Ross, M.

    1998-05-01

    Wire scanning beam profile monitors are used at the Stanford Linear Collider (SLC) for emittance preservation control and beam optics optimization. Twenty such scanners have proven most useful for this purpose and have performed a total of 1.5 million scans in the 4 to 6 years since their installation. Most of the essential scanners are equipped with 20 to 40 microm tungsten wires. SLC bunch intensities and sizes often exceed 2 x 10 7 particles/microm 2 (3C/m 2 ). The authors believe that this has caused a number of tungsten wire failures that appear at the ends of the wire, near the wire support points, after a few hundred scans are accumulated. Carbon fibers, also widely used at SLAC, have been substituted in several scanners and have performed well. In this paper, the authors present theories for the wire failure mechanism and techniques learned in reducing the failures

  3. Power supply in a wire mill; Energiefuehrungen sind schwer auf Draht

    Energy Technology Data Exchange (ETDEWEB)

    Roth-Stahl, Ingelore [Kabelschlepp GmbH, Wenden-Gerlingen (Germany). International Fairs and Public Relation

    2009-09-15

    Near Rotterdam, steel producer Ovako operates a wire mill including a coating and pickling unit. The pickling unit has a capacity of 450,000 tpa of wire and is one of the biggest of its kind. The cranes and lifting gear for transporting wire coils and operating the dipping tanks have plastic power tracks for uninterrupted operation. (orig.)

  4. Properties of stabilized MgB2 composite wire with Ti barrier

    International Nuclear Information System (INIS)

    Kovac, P; Husek, I; Melisek, T; Holubek, T

    2007-01-01

    Stabilized four-filament in situ MgB 2 /Ti/Cu/Monel composite wire was produced by the rectangular wire-in-tube (RWIT) technique. 10 wt% of nanosize SiC was added into the Mg-B powder mixture, which was packed into the Ti/Cu and Monel tubes, respectively. The assembled composite was two-axially rolled into wire and/or tape form and sintered at temperatures of 650-850 deg. C/0.5 h. Stabilized MgB 2 wire with Ti barrier is studied in terms of field-dependent transport critical current density, effects of filament size reduction and thermal stability

  5. Seeded perturbations in wire array Z-Pinches

    International Nuclear Information System (INIS)

    Robinson, Allen Conrad; Fedin, Dmitry; Kantsyrev, Victor Leonidovich; Wunsch, Scott Edward; Oliver, Bryan Velten; Lebedev, Sergey V.; Coverdale, Christine Anne; Ouart, Nicholas D.; LePell, Paul David; Safronova, Alla S.; Shrestha, I.; McKenney, John Lee; Ampleford, David J.; Rapley, J.; Bott, S.C.; Palmer, J.B.A.; Sotnikov, Vladimir Isaakovich; Bland, Simon Nicholas; Ivanov, Vladimir V.; Chittenden, Jeremy Paul; Jones, B.; Garasi, Christopher Joseph; Hall, Gareth Neville; Yilmaz, M. Faith; Mehlhorn, Thomas Alan; Deeney, Christopher; Pokala, S.; Nalajala, V.

    2005-01-01

    Controlled seeding of perturbations is employed to study the evolution of wire array z-pinch implosion instabilities which strongly impact x-ray production when the 3D plasma stagnates on axis. Wires modulated in radius exhibit locally enhanced magnetic field and imploding bubble formation at discontinuities in wire radius due to the perturbed current path. Wires coated with localized spectroscopic dopants are used to track turbulent material flow. Experiments and MHD modeling offer insight into the behavior of z-pinch instabilities.

  6. Surface state of the wire electrode and its influence on the application characteristics in MAG welding

    International Nuclear Information System (INIS)

    Piffer, W.; Marques, P.V.; Modenesi, P.J.

    1997-01-01

    This work presents an evaluation of the effect of the surface condition of the wire on GMA welding performance. Three wires samples were produced from the same steel heat with different surface conditions. Short circuit transfer welding trials were performed for two wire feed rates and different voltage levels. These tests indicated that stability tended to be worse and spatter level higher for the lowest and the highest welding voltage operation and the wire with no copper coating. No major difference was observed for intermediate voltage operation. Scanning electron microscopy of contact tips suggested that cooper coated wires produced less erosion on the tips. Electrical resistance of wires and friction forces between wires and contact tip were also evaluated and used to analyze differences in influence of wire surface condition on welding results. (Author) 14 refs

  7. Base Information Transport Infrastructure Wired (BITI Wired)

    Science.gov (United States)

    2016-03-01

    2016 Major Automated Information System Annual Report Base Information Transport Infrastructure Wired (BITI Wired) Defense Acquisition Management...Combat Information Transport System program was restructured into two pre-Major Automated Information System (pre-MAIS) components: Information...Major Automated Information System MAIS OE - MAIS Original Estimate MAR – MAIS Annual Report MDA - Milestone Decision Authority MDD - Materiel

  8. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  9. Wire electric-discharge machining and other fabrication techniques

    Science.gov (United States)

    Morgan, W. H.

    1983-01-01

    Wire electric discharge machining and extrude honing were used to fabricate a two dimensional wing for cryogenic wind tunnel testing. Electric-discharge cutting is done with a moving wire electrode. The cut track is controlled by means of a punched-tape program and the cutting feed is regulated according to the progress of the work. Electric-discharge machining involves no contact with the work piece, and no mechanical force is exerted. Extrude hone is a process for honing finish-machined surfaces by the extrusion of an abrasive material (silly putty), which is forced through a restrictive fixture. The fabrication steps are described and production times are given.

  10. Data analysis of event tape and connection

    International Nuclear Information System (INIS)

    Gong Huili

    1995-01-01

    The data analysis on the VAX-11/780 computer is briefly described, the data is from the recorded event tape of JUHU data acquisition system on the PDP-11/44 computer. The connection of the recorded event tapes of the XSYS data acquisition system on VAX computer is also introduced

  11. Device measures static friction of magnetic tape

    Science.gov (United States)

    Cole, P. T.

    1967-01-01

    Device measures the coefficient of static friction of magnetic tape over a range of temperatures and relative humidities. It uses a strain gage to measure the force of friction between a reference surface and the tape drawn at a constant velocity of approximately 0.0001 inch per second relative to the reference surface.

  12. Multiple Generations on Video Tape Recorders.

    Science.gov (United States)

    Wiens, Jacob H.

    Helical scan video tape recorders were tested for their dubbing characteristics in order to make selection data available to media personnel. The equipment, two recorders of each type tested, was submitted by the manufacturers. The test was designed to produce quality evaluations for three generations of a single tape, thereby encompassing all…

  13. YBCO coated conductors by reactive thermal co-evaporation

    Energy Technology Data Exchange (ETDEWEB)

    Schmatz, U.; Hoffmann, Ch.; Bauer, M.; Metzger, R.; Berberich, P.; Kinder, H. [Technische Univ. Muenchen, Garching (Germany). Physik-Department

    2001-12-01

    Coated tape conductors of YBCO require a deposition process allowing to obtain a high volume growth rate in order to produce long lengths of tape in a reasonable amount of time. We present our tape coating system where 15 parallel loops of travelling tape of 1 cm width can be coated simultaneously by reactive thermal co-evaporation. For high critical current densities, in-plane alignment of the YBCO film is necessary. Inclined substrate deposition (ISD) is a technique that allows to deposit in-plane oriented buffer layers suitable for YBCO growth at high deposition rates. We present results obtained for YBCO films grown on MgO-ISD buffer layers deposited by e-gun evaporation onto metallic tape substrates. (orig.)

  14. Flux transformers made of commercial high critical temperature superconducting wires.

    Science.gov (United States)

    Dyvorne, H; Scola, J; Fermon, C; Jacquinot, J F; Pannetier-Lecoeur, M

    2008-02-01

    We have designed flux transformers made of commercial BiSCCO tapes closed by soldering with normal metal. The magnetic field transfer function of the flux transformer was calculated as a function of the resistance of the soldered contacts. The performances of different kinds of wires were investigated for signal delocalization and gradiometry. We also estimated the noise introduced by the resistance and showed that the flux transformer can be used efficiently for weak magnetic field detection down to 1 Hz.

  15. Tape SCSI monitoring and encryption at CERN

    Science.gov (United States)

    Laskaridis, Stefanos; Bahyl, V.; Cano, E.; Leduc, J.; Murray, S.; Cancio, G.; Kruse, D.

    2017-10-01

    CERN currently manages the largest data archive in the HEP domain; over 180PB of custodial data is archived across 7 enterprise tape libraries containing more than 25,000 tapes and using over 100 tape drives. Archival storage at this scale requires a leading edge monitoring infrastructure that acquires live and lifelong metrics from the hardware in order to assess and proactively identify potential drive and media level issues. In addition, protecting the privacy of sensitive archival data is becoming increasingly important and with it the need for a scalable, compute-efficient and cost-effective solution for data encryption. In this paper, we first describe the implementation of acquiring tape medium and drive related metrics reported by the SCSI interface and its integration with our monitoring system. We then address the incorporation of tape drive real-time encryption with dedicated drive hardware into the CASTOR [1] hierarchical mass storage system.

  16. Preparation and characterization of Bi-2223 tapes

    International Nuclear Information System (INIS)

    Hense, K.; Kirchmayr, H.; Kovac, P.; Lackner, R.; Mueller, M.; Pachla, W.; Pitel, J.; Polak, M.; Usak, P.

    2003-01-01

    In a concerted action between Austrian, Slovakian and Polish research institutes Bi-2223 tapes have been prepared and characterized by different physical methods. Metallographic studies by optical as well as electron microscopy, measurements of critical current (angle dependent) and losses have been performed. Properties of individual filaments extracted from multifilamentary tapes were also studied. Uniformity of local I C of these filaments were considerably lower than that of the whole tape. This indicates that improvement of filament homogeneity could improve the over all J C in tapes. The application of these tapes for optimized magnet coils will also be discussed. From these investigations a better understanding of the mechanisms, limiting the critical current could be achieved and more optimized preparation methods can be envisioned

  17. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  18. Effect of wire shape on wire array discharge

    Energy Technology Data Exchange (ETDEWEB)

    Shimomura, N.; Tanaka, Y.; Yushita, Y.; Nagata, M. [University of Tokushima, Department of Electrical and Electronic Engineering, Tokushima (Japan); Teramoto, Y.; Katsuki, S.; Akiyama, H. [Kumamoto University, Department of Electrical and Computer Engineering, Kumamoto (Japan)

    2001-09-01

    Although considerable investigations have been reported on z-pinches to achieve nuclear fusion, little attention has been given from the point of view of how a wire array consisting of many parallel wires explodes. Instability existing in the wire array discharge has been shown. In this paper, the effect of wire shape in the wire array on unstable behavior of the wire array discharge is represented by numerical analysis. The claws on the wire formed in installation of wire may cause uniform current distribution on wire array. The effect of error of wire diameter in production is computed by Monte Carlo Method. (author)

  19. Effect of wire shape on wire array discharge

    International Nuclear Information System (INIS)

    Shimomura, N.; Tanaka, Y.; Yushita, Y.; Nagata, M.; Teramoto, Y.; Katsuki, S.; Akiyama, H.

    2001-01-01

    Although considerable investigations have been reported on z-pinches to achieve nuclear fusion, little attention has been given from the point of view of how a wire array consisting of many parallel wires explodes. Instability existing in the wire array discharge has been shown. In this paper, the effect of wire shape in the wire array on unstable behavior of the wire array discharge is represented by numerical analysis. The claws on the wire formed in installation of wire may cause uniform current distribution on wire array. The effect of error of wire diameter in production is computed by Monte Carlo Method. (author)

  20. Coated powder for electrolyte matrix for carbonate fuel cell

    International Nuclear Information System (INIS)

    Iacovangelo, C.D.; Browall, K.W.

    1985-01-01

    A plurality of electrolyte carbonate-coated ceramic particle which does not differ significantly in size from that of the ceramic particle and wherein no significant portion of the ceramic particle is exposed is fabricated into a porous tape comprised of said coated-ceramic particles bonded together by the coating for use in a molten carbonate fuel cell

  1. Epitaxial solution deposition of YBa2Cu3O7-6 coated conductors.

    Energy Technology Data Exchange (ETDEWEB)

    Overmyer, Donald L.; Clem, Paul Gilbert; Siegal, Michael P.; Holesinger, Terry A. (Los Alamos National Laboratory, Los Alamos, NM); Voigt, James A.; Richardson, Jacob J.; Dawley, Jeffrey Todd

    2004-11-01

    A variety of solution deposition routes have been reported for processing complex perovskite-based materials such as ferroelectric oxides and conductive electrode oxides, due to ease of incorporating multiple elements, control of chemical stoichiometry, and feasibility for large area deposition. Here, we report an extension of these methods toward long length, epitaxial film solution deposition routes to enable biaxially oriented YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} (YBCO)-coated conductors for superconducting transmission wires. Recent results are presented detailing an all-solution deposition approach to YBCO-coated conductors with critical current densities J{sub c} (77 K) > 1 MA/cm{sup 2} on rolling-assisted, biaxially textured, (200)-oriented Ni-W alloy tapes. Solution-deposition methods such as this approach and those of other research groups appear to have promise to compete with vapor phase methods for superconductor electrical properties, with potential advantages for large area deposition and low cost/kA {center_dot} m of wire.

  2. White House Tapes of the Nixon Administration, 1971 to 1973

    Data.gov (United States)

    National Archives and Records Administration — This dataset provides information about the Nixon Administration's White House Tapes. The White House Tapes contain sound recordings of President Richard Nixon's...

  3. Progress in second-generation HTS wire development and manufacturing

    International Nuclear Information System (INIS)

    Selvamanickam, V.; Chen, Y.; Xiong, X.; Xie, Y.; Zhang, X.; Rar, A.; Martchevskii, M.; Schmidt, R.; Lenseth, K.; Herrin, J.

    2008-01-01

    2007 has marked yet another year of continued rapid progress in developing and manufacturing high-performance, long-length second-generation (2G) HTS wires at high speeds. Using ion beam assisted deposition (IBAD) MgO and associated buffer sputtering processes, SuperPower has now exceeded piece lengths of 1000 m of fully buffered tape reproducibly with excellent in-plane texture of 6-7 degrees and uniformity of about 2%. These kilometer lengths are produced at high speeds of about 350 m/h of 4 mm wide tape. In combination with metal organic chemical vapor deposition (MOCVD), 2G wires up to single piece lengths to 790 m with a minimum critical current value of 190 A/cm corresponding to a Critical current x Length performance of 150,100 Am have been achieved. Tape speeds up to 180 m/h have been reached MOCVD while maintaining critical currents above 200 A/cm in 100+ m lengths. Thick film MOCVD technology has been transitioned to Pilot manufacturing system where a minimum critical current of 320 A/cm has been demonstrated over a length of 155 m processed at a speed of 70 m/h in 4 mm width. Finally, nearly 10,000 m of 2G wire has been produced, exhaustively tested, and delivered to the Albany Cable project. The average minimum critical current of the wire delivered in 225 segments of 43-44 m is 70 A in 4 mm widths. A 30 m cable has been fabricated with this wire by Sumitomo Electric and has been installed in the power grid of National Grid in downtown Albany and is the world's first 2G device installed in the grid

  4. Progress in second-generation HTS wire development and manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V. [SuperPower, Inc., 450 Duane Avenue, Schenectady, NY 12304 (United States)], E-mail: vselva@superpower-inc.com; Chen, Y.; Xiong, X.; Xie, Y.; Zhang, X.; Rar, A.; Martchevskii, M.; Schmidt, R.; Lenseth, K.; Herrin, J. [SuperPower, Inc., 450 Duane Avenue, Schenectady, NY 12304 (United States)

    2008-09-15

    2007 has marked yet another year of continued rapid progress in developing and manufacturing high-performance, long-length second-generation (2G) HTS wires at high speeds. Using ion beam assisted deposition (IBAD) MgO and associated buffer sputtering processes, SuperPower has now exceeded piece lengths of 1000 m of fully buffered tape reproducibly with excellent in-plane texture of 6-7 degrees and uniformity of about 2%. These kilometer lengths are produced at high speeds of about 350 m/h of 4 mm wide tape. In combination with metal organic chemical vapor deposition (MOCVD), 2G wires up to single piece lengths to 790 m with a minimum critical current value of 190 A/cm corresponding to a Critical current x Length performance of 150,100 Am have been achieved. Tape speeds up to 180 m/h have been reached MOCVD while maintaining critical currents above 200 A/cm in 100+ m lengths. Thick film MOCVD technology has been transitioned to Pilot manufacturing system where a minimum critical current of 320 A/cm has been demonstrated over a length of 155 m processed at a speed of 70 m/h in 4 mm width. Finally, nearly 10,000 m of 2G wire has been produced, exhaustively tested, and delivered to the Albany Cable project. The average minimum critical current of the wire delivered in 225 segments of 43-44 m is 70 A in 4 mm widths. A 30 m cable has been fabricated with this wire by Sumitomo Electric and has been installed in the power grid of National Grid in downtown Albany and is the world's first 2G device installed in the grid.

  5. A Novel Method of Coating Orthodontic Archwires with Nanoparticles

    Science.gov (United States)

    Syed, Shibli S; Kulkarni, Dinraj; Todkar, Rohit; Bagul, Ravikiran S; Parekh, Kreena; Bhujbal, Nikita

    2015-01-01

    Background: The major hazard to the orthodontic tooth movement is the friction developing at the bracket wire interface. In the past, there have been various attempts to reduce this friction. We believe that coating the commercially available orthodontic wires with nanoparticles can result in a successful reduction of this friction. The objective of this study is to develop a novel method of coating orthodontic archwires with nanoparticles. Materials and Methods: Stainless steel (Ormco, CA, USA), titanium molybdenum alloy (Ormco, CA, USA) and nickel-titanium (G and H Wire Company, USA) orthodontic wires with a rectangular cross-section dimension of 0.019”× 0.025”, were selected. The wires were later coated with a uniform and smooth nanoparticle film using 100 ml nanocremics. The coating procedure described in this article is a sol-gel thin film dip coating method. Results: The coating procedure was verified by comparing the surface topography of nanocoated archwires with the commercially available archwires in an environmental scanning electron microscope (ESEM). The ESEM images prove that the surface topography of the coated wires was found to be smoother with less surface deteriorations as compared to the commercially available wires. Conclusion: Commercially available orthodontic wires can be successfully coated using a novel method of sol-gel thin film dip coating method. PMID:26028899

  6. Simulation of transport critical current of Bi2223/Ag tape with ferromagnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)], E-mail: guchen@tsinghua.edu.cn; Alamgir, A.K.M. [Faculty of Engineering, Yokohama National University, 75-9 Tokiwadai, Hodogaya, ku, Yokohama (Japan); Qu, T.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory for Advanced Materials Processing Technology, Ministry of Education (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)

    2008-09-15

    Ferromagnetic shielding (FS) was coated onto the surface of the Bi2223/Ag multi-filamentary tape. Transport critical current of the Bi2223/Ag multi-filamentary tape with a FS was systematically studied by numerical simulation. In the help of a finite element analysis (FEA) tool, we are able to understand how the FS alters the flux inside the superconductor region and thus increases and decreases the critical current density locally. The results show the open FS function both positively and negatively to the performance of the tape. An optimization process was proposed, aiming to reach a tradeoff between I{sub c} increasing and less usage of the ferromagnetic material. Three important shielding parameters, shielding width, shielding thickness, and shielding material were taken into account.

  7. Simulation of transport critical current of Bi2223/Ag tape with ferromagnetic shielding

    International Nuclear Information System (INIS)

    Gu, C.; Alamgir, A.K.M.; Qu, T.M.; Han, Z.

    2008-01-01

    Ferromagnetic shielding (FS) was coated onto the surface of the Bi2223/Ag multi-filamentary tape. Transport critical current of the Bi2223/Ag multi-filamentary tape with a FS was systematically studied by numerical simulation. In the help of a finite element analysis (FEA) tool, we are able to understand how the FS alters the flux inside the superconductor region and thus increases and decreases the critical current density locally. The results show the open FS function both positively and negatively to the performance of the tape. An optimization process was proposed, aiming to reach a tradeoff between I c increasing and less usage of the ferromagnetic material. Three important shielding parameters, shielding width, shielding thickness, and shielding material were taken into account

  8. Test results of fault current limiter using YBCO tapes with shunt protection

    Energy Technology Data Exchange (ETDEWEB)

    Baldan, Carlos A; Lamas, Jerika S; Shigue, Carlos Y [Escola de Engenharia de Lorena, EEL USP, Lorena - SP (Brazil); Filho, Ernesto Ruppert, E-mail: cabaldan@gmail.co [Faculdade de Engenharia Eletrica, FEEC Unicamp, Campinas - SP (Brazil)

    2010-06-01

    A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper.

  9. Melt formed superconducting joint between superconducting tapes

    International Nuclear Information System (INIS)

    Benz, M.G.; Knudsen, B.A.; Rumaner, L.E.; Zaabala, R.J.

    1992-01-01

    This patent describes a superconducting joint between contiguous superconducting tapes having an inner laminate comprised of a parent-metal layer selected from the group niobium, tantalum, technetium, and vanadium, a superconductive intermetallic compound layer on the parent-metal layer, a reactive-metal layer that is capable of combining with the parent-metal and forming the superconductive intermetallic compound, the joint comprising: a continuous precipitate of the superconductive intermetallic compound fused to the tapes forming a continuous superconducting path between the tapes

  10. Kinesio Taping Fundamentals for the Equine Athlete.

    Science.gov (United States)

    Molle, Sybille

    2016-04-01

    The Kinesio taping method was developed in Japan for use in humans in 1979. The use of complementary therapies is becoming common in equine athletes and the discovery of Kinesio taping potential brought it into the animal world. Kinesio taping can be used to treat a wide range of clinical conditions, from tendon injuries to neurologic disorders and from muscle contractures to postural insufficiencies. Its use in veterinary medicine is promising, but relies heavily on evidence-based clinical reports. Further scientific research is needed to fully understand the real effectiveness of application. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Tape Cassette Bacteria Detection System

    Science.gov (United States)

    1973-01-01

    The design, fabrication, and testing of an automatic bacteria detection system with a zero-g capability and based on the filter-capsule approach is described. This system is intended for monitoring the sterility of regenerated water in a spacecraft. The principle of detection is based on measuring the increase in chemiluminescence produced by the action of bacterial porphyrins (i.e., catalase, cytochromes, etc.) on a luminol-hydrogen peroxide mixture. Since viable as well as nonviable organisms initiate this luminescence, viable organisms are detected by comparing the signal of an incubated water sample with an unincubated control. Higher signals for the former indicate the presence of viable organisms. System features include disposable sealed sterile capsules, each containing a filter membrane, for processing discrete water samples and a tape transport for moving these capsules through a processing sequence which involves sample concentration, nutrient addition, incubation, a 4 Molar Urea wash and reaction with luminol-hydrogen peroxide in front of a photomultiplier tube. Liquids are introduced by means of a syringe needle which pierces a rubber septum contained in the wall of the capsule. Detection thresholds obtained with this unit towards E. coli and S. marcescens assuming a 400 ml water sample are indicated.

  12. Flux pinning in bronze-processed Nb3Sn wires

    International Nuclear Information System (INIS)

    Suenaga, M.; Welch, D.O.

    1980-01-01

    The scaling law derived by Kramer for magnetic flux pinning in high magnetic fields was examined for its applicability to the magnetic field dependence of critical-current densities in the bronze processed monofilamentary Nb 3 Sn wires. From this it was concluded that: (1) its prediction for the form of the dependence of critical current on magnetic field and grain size [/J vector /sub c/ x H vector/ approx. h/sup 1/2/(1-h) 2 (1-a 0 √rho) -2 ] was found to be very good in most cases including wires with very small Nb 3 Sn grains (approx. 400 A). It was found very useful in comparison of J/sub c/ for different wires and in extrapolating to obtain H/sub c2/ for these wires. (2) However, it could not account consistently for the anisotropy in critical current of a tape which was measured with H applied perpendicular and parallel to the tape face. (3) The values of kappa 1 which were determined with the scaling law were too small by a factor of 2 to 3, and the trend in the variation with heat-treating time was opposite to that which is reasonably to be expected. That the behavior of kappa 1 is thus seriously in contradiction with the expected behavior for Nb 3 Sn suggests basic faults in the derivation of the scaling equation for critical currents at high magnetic fields

  13. Body of Knowledge (BOK) for Copper Wire Bonds

    Science.gov (United States)

    Rutkowski, E.; Sampson, M. J.

    2015-01-01

    Copper wire bonds have replaced gold wire bonds in the majority of commercial semiconductor devices for the latest technology nodes. Although economics has been the driving mechanism to lower semiconductor packaging costs for a savings of about 20% by replacing gold wire bonds with copper, copper also has materials property advantages over gold. When compared to gold, copper has approximately: 25% lower electrical resistivity, 30% higher thermal conductivity, 75% higher tensile strength and 45% higher modulus of elasticity. Copper wire bonds on aluminum bond pads are also more mechanically robust over time and elevated temperature due to the slower intermetallic formation rate - approximately 1/100th that of the gold to aluminum intermetallic formation rate. However, there are significant tradeoffs with copper wire bonding - copper has twice the hardness of gold which results in a narrower bonding manufacturing process window and requires that the semiconductor companies design more mechanically rigid bonding pads to prevent cratering to both the bond pad and underlying chip structure. Furthermore, copper is significantly more prone to corrosion issues. The semiconductor packaging industry has responded to this corrosion concern by creating a palladium coated copper bonding wire, which is more corrosion resistant than pure copper bonding wire. Also, the selection of the device molding compound is critical because use of environmentally friendly green compounds can result in internal CTE (Coefficient of Thermal Expansion) mismatches with the copper wire bonds that can eventually lead to device failures during thermal cycling. Despite the difficult problems associated with the changeover to copper bonding wire, there are billions of copper wire bonded devices delivered annually to customers. It is noteworthy that Texas Instruments announced in October of 2014 that they are shipping microcircuits containing copper wire bonds for safety critical automotive applications

  14. Towards plant wires

    OpenAIRE

    Adamatzky, Andrew

    2014-01-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self...

  15. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    OpenAIRE

    Biju Chetri, U.T. Ifthikar Ali, Madhusmita Koch, Abhijit Dutta

    2016-01-01

    Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected...

  16. Photovoltaic Wire, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  17. Charpak hemispherical wire chamber

    CERN Multimedia

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  18. Transport properties of different BSCCO wires

    International Nuclear Information System (INIS)

    Metra, P.; Gherardi, L.; Vellego, G.; Masini, R.; Zannella, S.

    1990-01-01

    This paper reports on two classes of solver sheathed BSCCO wires and laminates were prepared from 2223 (Pb substituted) and 2212 powders, respectively, by the powder in tube method. By suitable heat treatments (sintering and annealing below the melting temperature for 2223, melting + annealing for 2212), we obtained sample wires with Tc of ∼110 and ∼85 K respectively, comparable Jc at 77 K (∼10 3 A/cm 2 ), and dramatically different transport behavior. Measurements of critical current at different temperatures and as a function of applied magnetic field were carried out, to characterize the two classes of samples, together with other electrical testing (e.g. d.c. susceptibility) and structural analyses. The granular nature of the higher Tc BSCCO, qualitatively similar to the one of YBCO, was well documented. The melt-processed material showed no apparent granularity, but very strong field dependence of Jc at high temperature. The effect of mechanical deformation on Jc was also investigated by bending samples on different diameters before and after heat treatment. Wires and tapes with 2212 were found to be bendable on very small diameters before treatment, but also the 2223 filled samples were shown to accept significant deformation before sintering

  19. Ankle inversion taping using kinesiology tape for treating medial ankle sprain in an amateur soccer player

    OpenAIRE

    Lee, Sun-Min; Lee, Jung-Hoon

    2015-01-01

    [Purpose] The purpose of this study was to report the effects of ankle inversion taping using kinesiology tape in a patient with a medial ankle sprain. [Subject] A 28-year-old amateur soccer player suffered a Grade 2 medial ankle sprain during a match. [Methods] Ankle inversion taping was applied to the sprained ankle every day for 2 months. [Results] His symptoms were reduced after ankle inversion taping application for 2 months. The self-reported function score, the reach distances in the S...

  20. A COMPARITIVE STUDY ON EFFECTIVENESS OF TAPING WITH IONTOPHORESIS AND TAPING ALONE IN CHRONIC PLANTAR FASCITIS

    Directory of Open Access Journals (Sweden)

    Biju Chetri

    2016-04-01

    Full Text Available Background: Plantar fasciitis is a painful condition caused by microtrauma to plantar fascia due to overuse. It is a most common cause of heel pain in runners. Various studies proved taping and Iontophoresis as effective in the treating plantar fasciitis. But there are no studies comparing the combined effect of iontophoresis with taping and taping alone in the treatment of plantar fasciitis. Methods: 50 patients suffering from plantar fasciitis who met the inclusion criteria were selected. The subjects were randomly divided into two groups i.e. Group A and Group B. Group A received taping, iontophoresis with plantar fascia stretching. Group B received taping and plantar fascia stretching. A total of 6 treatment sessions were given on alternate days over a period of two weeks for both the groups. Results: VAS and FFI scores across baseline and post intervention showed a significant improvement statistically in their mean scores between Groups A and B (P<0.05. Between group comparison of VAS and FFI scores, it showed that subject treated with Iontophoresis in combination with taping and plantar fascia stretch (Group A had significant improvement in VAS and functional ability when compared to subjects treated with taping and plantar fascia stretching alone (Group B. Conclusion: Iontophoresis along with Taping and plantar fascia stretching gave an additional benefit when compared with Taping and plantar fascia stretching alone in reducing pain and improving function in plantar fasciitis.

  1. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    Energy Technology Data Exchange (ETDEWEB)

    Kurihara, Chihaya, E-mail: chihaya.kurihara@jp.fujikura.com [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro [Fujikura Ltd., 1440, Mutsuzaki, Sakura, Chiba 285-8550 (Japan); Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka [Kyushu University, 744 Motooka, Nishi-Ku, Fukuoka 819-0395 (Japan)

    2016-11-15

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I{sub c} measurement, we found that our new multi-filamentary tape could provide almost equal I{sub c} compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  2. Multi-filamentary REBCO tapes fabricated by scratching a buffer layer along the tape longitudinal direction

    International Nuclear Information System (INIS)

    Kurihara, Chihaya; Fujita, Shinji; Nakamura, Naonori; Igarashi, Mitsunori; Iijima, Yasuhiro; Higashikawa, Kohei; Uetsuhara, Dai; Kiss, Takanobu; Iwakuma, Masataka

    2016-01-01

    Highlights: • We developed new method of slitting tape between buffer layer processes for multi-filamentary tape. • By scratching buffer layer along the tape longitudinal direction, we find that REBCO layer is divided easily without damaging it. • We have developed 100 m class multi-filamentary REBCO tapes which are suitable for superconducting coils. - Abstract: A method for making multi-filamentary REBCO tapes by only scratching buffer layer was developed for coil application which requires accurate magnetic fields. By continuous I_c measurement, we found that our new multi-filamentary tape could provide almost equal I_c compared to conventional tapes. Then, using EBSD and RTR-SHPM methods, a divided structure of REBCO layer was surely confirmed. AC loss was also decreased. Furthermore, the result of delamination test of our new multi-filamentary tape showed enough mechanical property. As a result, we have succeeded in developing 100 m class multi-filamentary tape for superconducting coil.

  3. 1998 wire development workshop proceedings

    International Nuclear Information System (INIS)

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development

  4. 1998 wire development workshop proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development.

  5. Levitation characteristics of HTS tape stacks

    Energy Technology Data Exchange (ETDEWEB)

    Pokrovskiy, S. V.; Ermolaev, Y. S.; Rudnev, I. A. [National Research Nuclear University MEPhI (Moscow Engineering Physics Institute), Moscow (Russian Federation)

    2015-03-15

    Due to the considerable development of the technology of second generation high-temperature superconductors and a significant improvement in their mechanical and transport properties in the last few years it is possible to use HTS tapes in the magnetic levitation systems. The advantages of tapes on a metal substrate as compared with bulk YBCO material primarily in the strength, and the possibility of optimizing the convenience of manufacturing elements of levitation systems. In the present report presents the results of the magnetic levitation force measurements between the stack of HTS tapes containing of tapes and NdFeB permanent magnet in the FC and ZFC regimes. It was found a non- linear dependence of the levitation force from the height of the array of stack in both modes: linear growth at small thickness gives way to flattening and constant at large number of tapes in the stack. Established that the levitation force of stacks comparable to that of bulk samples. The numerical calculations using finite element method showed that without the screening of the applied field the levitation force of the bulk superconductor and the layered superconductor stack with a critical current of tapes increased by the filling factor is exactly the same, and taking into account the screening force slightly different.

  6. Metallurgical investigation of wire breakage of tyre bead grade

    Directory of Open Access Journals (Sweden)

    Piyas Palit

    2015-10-01

    Full Text Available Tyre bead grade wire is used for tyre making application. The wire is used as reinforcement inside the polymer of tyre. The wire is available in different size/section such as 1.6–0.80 mm thin Cu coated wire. During tyre making operation at tyre manufacturer company, wire failed frequently. In this present study, different broken/defective wire samples were collected from wire mill for detailed investigation of the defect. The natures of the defects were localized and similar in nature. The fracture surface was of finger nail type. Crow feet like defects including button like surface abnormalities were also observed on the broken wire samples. The defect was studied at different directions under microscope. Different advanced metallographic techniques have been used for detail investigation. The analysis revealed that, white layer of surface martensite was formed and it caused the final breakage of wire. In this present study we have also discussed about the possible reason for the formation of such kind of surface martensite (hard-phase.

  7. Coated particle waste form development

    International Nuclear Information System (INIS)

    Oma, K.H.; Buckwalter, C.Q.; Chick, L.A.

    1981-12-01

    Coated particle waste forms have been developed as part of the multibarrier concept at Pacific Northwest Laboratory under the Alternative Waste Forms Program for the Department of Energy. Primary efforts were to coat simulated nuclear waste glass marbles and ceramic pellets with low-temperature pyrolytic carbon (LT-PyC) coatings via the process of chemical vapor deposition (CVD). Fluidized bed (FB) coaters, screw agitated coaters (SAC), and rotating tube coaters were used. Coating temperatures were reduced by using catalysts and plasma activation. In general, the LT-PyC coatings did not provide the expected high leach resistance as previously measured for carbon alone. The coatings were friable and often spalled off the substrate. A totally different concept, thermal spray coating, was investigated at PNL as an alternative to CVD coating. Flame spray, wire gun, and plasma gun systems were evaluated using glass, ceramic, and metallic coating materials. Metal plasma spray coatings (Al, Sn, Zn, Pb) provided a two to three orders-of-magnitude increase in chemical durability. Because the aluminum coatings were porous, the superior leach resistance must be due to either a chemical interaction or to a pH buffer effect. Because they are complex, coated waste form processes rank low in process feasibility. Of all the possible coated particle processes, plasma sprayed marbles have the best rating. Carbon coating of pellets by CVD ranked ninth when compared with ten other processes. The plasma-spray-coated marble process ranked sixth out of eleven processes

  8. Wire Array Photovoltaics

    Science.gov (United States)

    Turner-Evans, Dan

    Over the past five years, the cost of solar panels has dropped drastically and, in concert, the number of installed modules has risen exponentially. However, solar electricity is still more than twice as expensive as electricity from a natural gas plant. Fortunately, wire array solar cells have emerged as a promising technology for further lowering the cost of solar. Si wire array solar cells are formed with a unique, low cost growth method and use 100 times less material than conventional Si cells. The wires can be embedded in a transparent, flexible polymer to create a free-standing array that can be rolled up for easy installation in a variety of form factors. Furthermore, by incorporating multijunctions into the wire morphology, higher efficiencies can be achieved while taking advantage of the unique defect relaxation pathways afforded by the 3D wire geometry. The work in this thesis shepherded Si wires from undoped arrays to flexible, functional large area devices and laid the groundwork for multijunction wire array cells. Fabrication techniques were developed to turn intrinsic Si wires into full p-n junctions and the wires were passivated with a-Si:H and a-SiNx:H. Single wire devices yielded open circuit voltages of 600 mV and efficiencies of 9%. The arrays were then embedded in a polymer and contacted with a transparent, flexible, Ni nanoparticle and Ag nanowire top contact. The contact connected >99% of the wires in parallel and yielded flexible, substrate free solar cells featuring hundreds of thousands of wires. Building on the success of the Si wire arrays, GaP was epitaxially grown on the material to create heterostructures for photoelectrochemistry. These cells were limited by low absorption in the GaP due to its indirect bandgap, and poor current collection due to a diffusion length of only 80 nm. However, GaAsP on SiGe offers a superior combination of materials, and wire architectures based on these semiconductors were investigated for multijunction

  9. Self Healing Coating/Film Project

    Science.gov (United States)

    Summerfield, Burton; Thompson, Karen; Zeitlin, Nancy; Mullenix, Pamela; Calle, Luz; Williams, Martha

    2015-01-01

    Kennedy Space Center (KSC) has been developing self healing materials and technologies. This project seeks to further develop self healing functionality in thin films for applications such as corrosion protective coatings, inflatable structures, space suit materials, and electrical wire insulation.

  10. Influence of self-field on the critical current of Bi-2223/Ag tapes

    International Nuclear Information System (INIS)

    Lehtonen, Jorma; Korpela, Aki; Nah, Wansoo; Kang, Joonsun; Kovac, Pavol; Melisek, Tibor

    2004-01-01

    The knowledge of critical current density in a superconducting wire is essential in order to compute AC losses. In HTS tapes the critical current density is difficult to estimate from the measured critical current because self-field tends to reduce the current carrying capacity. In this paper the critical current is measured with a single sample and with two similar samples connected in antiparallel in order to compensate the self-field. Both types of measurement are simulated with finite element method. The simulations help to understand the relation between the measured critical current and material properties. The results suggest that in a high quality tape the self-field effect reduced the measured critical current ∼25% if compared to the real critical current at the zero external field

  11. Commercial and Industrial Wiring.

    Science.gov (United States)

    Kaltwasser, Stan; Flowers, Gary

    This module is the third in a series of three wiring publications, includes additional technical knowledge and applications required for job entry in the commercial and industrial wiring trade. The module contains 15 instructional units that cover the following topics: blueprint reading and load calculations; tools and equipment; service;…

  12. Development and evaluation of a reinforced polymeric biomaterial for use as an orthodontic wire

    Science.gov (United States)

    Zufall, Scott William

    Composite archwires have the potential to provide esthetic and functional improvements over conventional wires. As part of an ongoing effort to bring these materials into general use, composite wires were fabricated using a photo-pultrusion manufacturing technique, and subsequently coated with a 10 mum layer of poly(chloro-p-xylylene). Coated and uncoated composites were subjected to several different evaluations to assess their ability to perform the functions of an orthodontic archwire. An investigation of the viscoelastic behavior of uncoated composite wires was conducted at a physiological temperature of 37°C using a bend stress relaxation test. Over 90 day testing periods, energy losses increased with decreasing reinforcement levels from to 8% of the initial wire stress. Final viscous losses were 1% for all reinforcement levels. Relaxed elastic moduli for the composite wires were comparable to the reported elastic moduli of conventional orthodontic wires that are typically used for initial and intermediate alignment procedures. Frictional characteristics were evaluated in passive and active configurations for uncoated composite wires against three contemporary orthodontic brackets. Kinetic coefficients of friction were the same for all wire-bracket combinations tested and were slightly lower than the reported coefficients of other initial and intermediate alignment wires. Wear patterns on the wires, which were largely caused by sharp leading edges of the bracket slots, were characteristic of plowing and cutting wear behaviors. This wear caused glass fibers to be released from the surface of the wires, presenting a potential irritant. Coated composite wires were subjected to the same frictional analysis as the uncoated wires. A mathematical model of the archwire-bracket system was derived using engineering mechanics, and used to define a coefficient of binding. The coating increased the frictional coefficients of the wires by 72%, yet the binding coefficient

  13. Methods and systems for fabricating high quality superconducting tapes

    Science.gov (United States)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  14. The status of commercial and developmental HTS wires

    Energy Technology Data Exchange (ETDEWEB)

    Masur, L.J.; Buczek, D.; Harley, E.; Kodenkandath, T.; Li, X.; Lynch, J.; Nguyen, N.; Rupich, M.; Schoop, U.; Scudiere, J.; Siegal, E.; Thieme, C.; Verebelyi, D.; Zhang, W.; Kellers, J

    2003-10-15

    This paper provides an update on the development, performance and application of first and second generation high temperature superconductor (HTS) wires fabricated at American Superconductor (AMSC). First generation, multifilamentary composite wire is available commercially today in different viable product forms. This conductor carries 140 x the current of copper of the same cross-section, and is robust enough to stand tough industrial requirements. Second generation HTS wires, having a coated conductor composite architecture, are under development today and achieved substantial progress recently. AMSC's first generation wire will continue as the workhorse of the industry for the next 3-4 years while AMSC's second generation coated conductor wire is on track to be reproducible, uniform, scalable, and low cost. This paper provides a product differentiation with a view on the application of HTS wire in the electric power sector. Basic engineering data is reviewed that shall aid the engineer in the selection of the HTS wire product.

  15. Experimental study on manufacturing of grits-spiral- distribution electroplated wire saw

    Directory of Open Access Journals (Sweden)

    Yufei GAO

    2016-12-01

    Full Text Available In order to obtain high performance electroplating diamond wire saw, experimental studies are conducted for development of grits-spiral-distribution electroplated diamond wire saw using sand-suspend electroplating method. The influences of pre-plating cathode current density, grits electro-embedding cathode current density and time on composite deposite coating appearance and grits distribution of wire saw are analyzed, and the sawing experiment is carried out by using the trial wire saw. The results show that good bonding strength between the coating and the steel wire can be obtained when the adopted cathode current density is 5.0 A/dm2 at pre-plating stage; good coating and girts distribution can be obtained when the adopted cathode current density is 5.0 A/dm2 and the electroplating time is 7~8 min at grits electro-embedding stage. By winding insulation wire on the surface of steel wire and reasonably selecting technological parameters before pre-plating can make the diamond wire saw with grits-spiral-distribution on surface, and the new type of wire saw has a better crumbs-clearing effect in wire sawing process.

  16. Strongly enhanced current densities in Sr0.6K0.4Fe2As2 + Sn superconducting tapes

    Science.gov (United States)

    Lin, He; Yao, Chao; Zhang, Xianping; Zhang, Haitao; Wang, Dongliang; Zhang, Qianjun; Ma, Yanwei; Awaji, Satoshi; Watanabe, Kazuo

    2014-03-01

    Improving transport current has been the primary topic for practical application of superconducting wires and tapes. However, the porous nature of powder-in-tube (PIT) processed iron-based tapes is one of the important reasons for low critical current density (Jc) values. In this work, the superconducting core density of ex-situ Sr0.6K0.4Fe2As2 + Sn tapes, prepared from optimized precursors, was significantly improved by employing a simple hot pressing as an alternative route for final sintering. The resulting samples exhibited optimal critical temperature (Tc), sharp resistive transition, small resistivity and high Vickers hardness (Hv) value. Consequently, the transport Jc reached excellent values of 5.1 × 104 A/cm2 in 10 T and 4.3 × 104 A/cm2 in 14 T at 4.2 K, respectively. Our tapes also exhibited high upper critical field Hc2 and almost field-independent Jc. These results clearly demonstrate that PIT pnictide wire conductors are very promising for high-field magnet applications.

  17. Strategy for robot motion and path planning in robot taping

    Science.gov (United States)

    Yuan, Qilong; Chen, I.-Ming; Lembono, Teguh Santoso; Landén, Simon Nelson; Malmgren, Victor

    2016-06-01

    Covering objects with masking tapes is a common process for surface protection in processes like spray painting, plasma spraying, shot peening, etc. Manual taping is tedious and takes a lot of effort of the workers. The taping process is a special process which requires correct surface covering strategy and proper attachment of the masking tape for an efficient surface protection. We have introduced an automatic robot taping system consisting of a robot manipulator, a rotating platform, a 3D scanner and specially designed taping end-effectors. This paper mainly talks about the surface covering strategies for different classes of geometries. The methods and corresponding taping tools are introduced for taping of following classes of surfaces: Cylindrical/extended surfaces, freeform surfaces with no grooves, surfaces with grooves, and rotational symmetrical surfaces. A collision avoidance algorithm is introduced for the robot taping manipulation. With further improvements on segmenting surfaces of taping parts and tape cutting mechanisms, such taping solution with the taping tool and the taping methodology can be combined as a very useful and practical taping package to assist humans in this tedious and time costly work.

  18. The role of oxide structure on copper wire to the rubber adhesion

    Science.gov (United States)

    Su, Yea-Yang; Shemenski, Robert M.

    2000-07-01

    Most metals have an oxide layer on the surface. However, the structure of the oxide varies with the matrix composition, and depends upon the environmental conditions. A bronze coating, nominal composition of 98.5% Cu and balance of Sn, is applied to steel wire for reinforcing pneumatic tire beads and to provide adhesion to rubber. This work studied the influence of copper oxides on the bronze coating on adhesion during vulcanization. To emphasize the oxide structures, electrolytic tough pitch (ETP) copper wire was used instead of the traditional bronze-coated tire bead wire. Experimental results confirmed the hypothesis that cuprous oxide (Cu 2O) could significantly improve bonding between copper wire and rubber, and demonstrated that the interaction between rubber and oxide layer on wire is an electrochemical reaction.

  19. Ubiquitous Graphene Electronics on Scotch Tape

    Science.gov (United States)

    Chung, Yoonyoung; Ho Kim, Hyun; Lee, Sangryun; Lee, Eunho; Won Kim, Seong; Ryu, Seunghwa; Cho, Kilwon

    2015-07-01

    We report a novel concept of graphene transistors on Scotch tape for use in ubiquitous electronic systems. Unlike common plastic substrates such as polyimide and polyethylene terephthalate, the Scotch tape substrate is easily attached onto various objects such as banknotes, curved surfaces, and human skin, which implies potential applications wherein electronics can be placed in any desired position. Furthermore, the soft Scotch tape serves as an attractive substrate for flexible/foldable electronics that can be significantly bent, or even crumpled. We found that the adhesive layer of the tape with a relatively low shear modulus relaxes the strain when subjected to bending. The capacitance of the gate dielectric made of oxidized aluminum oxide was 1.5 μF cm-2, so that a supply voltage of only 2.5 V was sufficient to operate the devices. As-fabricated graphene transistors on Scotch tape exhibited high electron mobility of 1326 (±155) cm2 V-1 s-1 the transistors still showed high mobility of 1254 (±478) cm2 V-1 s-1 even after they were crumpled.

  20. Textured YBCO films grown on wires: application to superconducting cables

    International Nuclear Information System (INIS)

    Dechoux, N; Jiménez, C; Chaudouët, P; Rapenne, L; Sarigiannidou, E; Robaut, F; Petit, S; Garaudée, S; Porcar, L; Soubeyroux, J L; Odier, P; Bruzek, C E; Decroux, M

    2012-01-01

    Efforts to fabricate superconducting wires made of YBa 2 Cu 3 O 7 (YBCO) on La 2 Zr 2 O 7 (LZO) buffered and biaxially textured Ni-5 at.%W (NiW) are described. Wires were manually shaped from LZO buffered NiW tapes. Different diameters were produced: 1.5, 2 and 3 mm. The wires were further covered with YBCO grown by metal organic chemical vapor deposition (MOCVD). We developed an original device in which the round substrate undergoes an alternated rotation of 180° around its axis in addition to a reel-to-reel translation. This new approach allows covering the whole circumference of the wire with a YBCO layer. This was confirmed by energy dispersive x-ray spectroscopy (EDX) analysis coupled to a scanning electron microscope (SEM). For all wire diameters, the YBCO layer thickness varied from 300 to 450 nm, and the cationic composition was respected. Electron backscattering diffraction (EBSD) measurements were performed directly on an as-deposited wire without surface preparation allowing the investigation of the crystalline quality of the film surface. Combining EBSD with XRD results we show that YBCO grows epitaxially on the LZO buffered NiW wires. For the first time, superconductive behaviors have been detected on round substrates in both the rolling and circular direction. J c reached 0.3 MA cm −2 as measured at 77 K by transport and third-harmonic detection. Those preliminary results confirm the effectiveness of the MOCVD for complex geometries, especially for YBCO deposition on small diameter wires. This approach opens huge perspectives for the elaboration of a new generation of YBCO-based round conductors. (paper)

  1. V-I transition and n-value of multifilamentary LTS and HTS wires and cables

    International Nuclear Information System (INIS)

    Ghosh, Arup K.

    2004-01-01

    For low T c multifilamentary conductors like NbTi and Nb 3 Sn, the V-I transition to the normal state is typically quantified by the parameter, n, defined by (ρ/ρ c )=(I/I c ) n . For NbTi, this parameterization has been very useful in the development of high J c wires, where the n-value is regarded as an index of the filament quality. In copper-matrix wires with undistorted filaments, the n-value at 5 T is ∼40-60, and drops monotonically with increasing field. However, n can vary significantly in conductors with higher resistivity matrices and those with a low copper fraction. Usually high n-values are associated with unstable resistive behavior and premature quenching. The n-value in NbTi Rutherford cables, when compared to that in the wires is useful in evaluating cabling degradation of the critical current due to compaction at the edges of the cable. In Nb 3 Sn wires, n-value has been a less useful tool, since often the resistive transition shows small voltages ∼ a few μV prior to quenching. However, in 'well behaved' wires, n is ∼30-40 at 12 T and also shows a monotonic behavior with field. Strain induced I c degradation in these wires is usually associated with lower n-values. For high T c multifilamentary wires and tapes, a similar power law often describes the resistive transition. At 4.2 K, Bi-2223 tapes as well as Bi-2212 wires exhibit n-values ∼15-20. In either case, n does not change appreciably with field. Rutherford cables of Bi-2212 wire show lower values of n than the virgin wire

  2. Towards plant wires.

    Science.gov (United States)

    Adamatzky, Andrew

    2014-08-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self-growing wetware circuits and devices, and integration of plant-based electronic components into future and emergent bio-hybrid systems. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  3. Thermosonic wire bonding of IC devices using palladium wire

    International Nuclear Information System (INIS)

    Shze, J.H.; Poh, M.T.; Tan, R.M.

    1996-01-01

    The feasibility of replacing gold wire by palladium wire in thermosonic wire bonding of CMOS and bipolar devices are studied in terms of the manufacturability, physical, electrical and assembly performance. The results that palladium wire is a viable option for bonding the bipolar devices but not the CMOS devices

  4. Wire-Arc-Sprayed Aluminum Protects Steel Against Corrosion

    Science.gov (United States)

    Zimmerman, Frank R.; Poorman, Richard; Sanders, Heather L.; Mckechnie, Timothy N.; Bonds, James W., Jr.; Daniel, Ronald L., Jr.

    1995-01-01

    Aluminum coatings wire-arc sprayed onto steel substrates found effective in protecting substrates against corrosion. Coatings also satisfy stringent requirements for adhesion and flexibility, both at room temperature and at temperatures as low as liquid hydrogen. Developed as alternatives to corrosion-inhibiting primers and paints required by law to be phased out because they contain and emit such toxic substances as chromium and volatile organic compounds.

  5. Nano-/micro metallic wire synthesis on Si substrate and their characterization

    International Nuclear Information System (INIS)

    Kaur, Jaskiran; Kaur, Harmanmeet; Singh, Surinder; Kanjilal, Dinakar; Chakarvarti, Shiv Kumar

    2014-01-01

    Nano-/micro wires of copper are grown on semiconducting Si substrate using the template method. It involves the irradiation of 8 um thick polymeric layer coated on Si with150 MeV Ni ion beam at a fluence of 2E8. Later, by using the simple technique of electrodeposition, copper nano-/micro wires were grown via template synthesis. Synthesized wires were morphologically characterized using SEM and electrical characterization was carried out by finding I-V plot

  6. CLEARANCE OF ARCHIVE TAPE VAULT (BUILDING 186)

    CERN Multimedia

    EP Division

    1999-01-01

    The archive tape vault is being cleared to make way for the LHC experiments silicon facility.Experiments were contacted in February to arrange for the extended storage or destruction of archived volumes. Any who have not yet done so are asked to contactR. Minchin/IT immediately.This is also an opportunity to clear unused tapes or cartridges from around the site and have them destroyed ecologically. Please contact ep.smi.helpdesk@cern.ch to arrange for collection.A.E. Ball/EP-SMI

  7. Modelling of Tape Casting for Ceramic Applications

    DEFF Research Database (Denmark)

    Jabbari, Masoud

    was increased by improving the steady state model with a quasi-steady state analytical model. In order to control the most important process parameter, tape thickness, the two-doctor blade configuration was also modeled analytically. The model was developed to control the tape thickness based on the machine...... for magnetic refrigeration applications. Numerical models were developed to track the migration of the particles inside the ceramic slurry. The results showed the presence of some areas inside the ceramic in which the concentration of the particles is higher compared to other parts, creating the resulting...

  8. Resistive coating for current conductors in cryogenic applications

    International Nuclear Information System (INIS)

    Hirayama, C.; Wagner, G.R.

    1982-01-01

    This invention relates to a resistive or semiconducting coating for use on current conductors in cryogenic applications. This includes copper-clad superconductor wire, copper wire used for stabilizing superconductor magnets, and for hyperconductors. The coating is a film of cuprous sulfide (Cu2S) that has been found not to degrade the properties of the conductors. It is very adherent to the respective conductors and satisfies the mechanical, thermal and electrical requirements of coatings for the conductors

  9. Placement suitability criteria of composite tape for mould surface in automated tape placement

    Directory of Open Access Journals (Sweden)

    Zhang Peng

    2015-10-01

    Full Text Available Automated tape placement is an important automated process used for fabrication of large composite structures in aeronautical industry. The carbon fiber composite parts realized with this process tend to replace the aluminum parts produced by high-speed machining. It is difficult to determine the appropriate width of the composite tape in automated tape placement. Wrinkling will appear in the tape if it does not suit for the mould surface. Thus, this paper deals with establishing placement suitability criteria of the composite tape for the mould surface. With the assumptions for ideal mapping and by applying some principles and theorems of differential geometry, the centerline trajectory of the composite tape is identified to follow the geodesic. The placement suitability of the composite tape is examined on three different types of non-developable mould surfaces and four criteria are derived. The developed criteria have been used to test the deposition process over several mould surfaces and the appropriate width for each mould surface is obtained by referring to these criteria.

  10. Wire chambers: Trends and alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Regler, Meinhard

    1992-05-15

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!.

  11. Cracking of Beams Strengthened with Externally Bonded SRP Tapes

    Science.gov (United States)

    Krzywoń, Rafał

    2017-10-01

    Paper discusses strengthening efficiency of relatively new kind of SRP composite based on high strength steel wires. They are made of ultra-high strength steel primarily used in cords of car tires. Through advanced treatment, the mechanical properties of SRP steel are similar to other high carbon cold drawn steels used in construction industry. Strength significantly exceed 2000 MPa, there is no perfect plasticity at yield stress level. Almost linear stress-strain relationship makes SRP steel mechanical properties similar to carbon fibers. Also flexibility and weight ratio of the composite overlay is slightly worse than CFRP strip. Despite these advantages SRP is not as popular as other composites reinforced with fibers of high strength. This is due to the small number of studies of SRP behavior and applicability. Paper shows selected results of the laboratory test of beams strengthened with use of SRP and CFRP externally bonded overlays. Attention has been focused primarily on the phenomenon of cracking. Comparison include the cracking moment, crack width and spacing, coverage of crack zone. Despite the somewhat lower rigidity of SRP tapes, they have a much better adhesion to concrete, so that the crack width is comparable in almost the whole load range. The paper also includes an assessment of the common methods of checking the condition of cracking in relation to the tested SRP strengthening. The paper presents actual calculation procedures to determine the crack spacing and crack width. The discussed formulas are verified with results of provided laboratory tests.

  12. Distanced Data: Transcribing Other People's Research Tapes

    Science.gov (United States)

    Tilley, Susan A.; Powick, Kelly D.

    2004-01-01

    In this article, we report on our qualitative study involving eight individuals hired to transcribe research tapes in university contexts. We consider issues of data analysis and data trustworthiness and the implications for both when transcription is assigned to someone other than the researcher. We explore the challenges transcribers faced…

  13. Localized leak detection utilizing moisture sensitive tape

    International Nuclear Information System (INIS)

    Riddle, P.

    1984-01-01

    Moisture sensitive tape (MST) has been used in various nuclear power plants to detect leaks in reactor piping systems. The sensor assembly consists of MST, transponder, and sensor carrier, and is installed on the exterior of thermal insulation. The components, applications, installation, and purchasing information are discussed in the paper

  14. Artificial Intelligence Controls Tape-Recording Sequence

    Science.gov (United States)

    Schwuttke, Ursula M.; Otamura, Roy M.; Zottarelli, Lawrence J.

    1989-01-01

    Developmental expert-system computer program intended to schedule recording of large amounts of data on limited amount of magnetic tape. Schedules recording using two sets of rules. First set incorporates knowledge of locations for recording of new data. Second set incorporates knowledge about issuing commands to recorder. Designed primarily for use on Voyager Spacecraft, also applicable to planning and sequencing in industry.

  15. "Space slitter" for film or tape

    Science.gov (United States)

    Johnson, W. H.

    1978-01-01

    Device cuts film or tape into strips by guiding film in channel under cutting blades. Device is operated by lifting pressure bar to insert blades into film. Film is then pulled through blades. Cutter has potential uses in advertising, commercial art, and publishing fields.

  16. Carbon Nanotube-Based Synthetic Gecko Tapes

    Science.gov (United States)

    Dhinojwala, Ali

    2008-03-01

    Wall-climbing geckos have unique ability to attach to different surfaces without the use of any viscoelastic glues. On coming in contact with any surface, the micron-size gecko foot-hairs deform, enabling molecular contact over large areas, thus translating weak van der Waals (vdW) interactions into enormous shear forces. We will present our recent results on the development of synthetic gecko tape using aligned carbon nanotubes to mimic the keratin hairs found on gecko feet. The patterned carbon nanotube-based gecko tape can support a shear stress (36 N/cm^2) nearly four times higher than the gecko foot and sticks to a variety of surfaces, including Teflon. Both the micron-size setae (replicated by nanotube bundles) and nanometer-size spatulas (individual nanotubes) are necessary to achieve macroscopic shear adhesion and to translate the weak vdW interactions into high shear forces. The carbon nanotube based tape offers an excellent synthetic option as a dry conductive reversible adhesive in microelectronics, robotics and space applications. The mechanism behind these large shear forces and self-cleaning properties of these carbon nanotube based synthetic gecko tapes will be discussed. This work was performed in collaboration with graduate students Liehui Ge, and Sunny Sethi, and collaborators from RPI; Lijie Ci and Professor Pulickel Ajayan.

  17. Method of making Nb3Sn composite wires and cables

    International Nuclear Information System (INIS)

    Scanlan, R.M.; Fietz, W.A.

    1977-01-01

    By providing a nickel or copper overcoat to a tin coating on a niobium-copper multifilamentary composite wire, one can avoid the necessity for choosing between poor superconducting properties due to tin droplet formation and substantially increasing production costs by adding a number of special processing steps. 9 claims, 1 figure

  18. Plated nickel wire mesh makes superior catalyst bed

    Science.gov (United States)

    Sill, M.

    1965-01-01

    Porous nickel mesh screen catalyst bed produces gas evolution in hydrogen peroxide thrust chambers used for attitude control of space vehicles. The nickel wire mesh disks in the catalyst bed are plated in rugose form with a silver-gold coating.

  19. Strand Burner Results of AFP-001 Propellant with Inert Coating for Temperature Compensation

    Science.gov (United States)

    2015-10-01

    there were 4 different configurations: baseline, a C-100 coated, an SC-11 coated, and a urethane acrylate (UA) coated. C-100 is a polyurea based...coating, SC-11 is an epoxy-based coating, and UA is a urethane- acrylate -based coating. These coatings were chosen to target a specific strength...Ignition was achieved by running current through a nichrome wire placed on top of the sample. Events were recorded with a Phantom high-speed camera

  20. Effect of binder concentration and blade gap on Yttria stabilized Zirconia tapes obtained by tape casting

    Energy Technology Data Exchange (ETDEWEB)

    Mena Garcia, J.; Reyes Rojas, A.; Rodriguez Gonzalez, C.A.; Hernandez Paz, J.; Garcia Casillas, P.E.; Enriquez Carrejo, J.L.; Camacho Montes, H.

    2016-07-01

    The tape casting method has kept its interest over the years due to the wide spectrum of its applications and its economic viability in comparison to other techniques focused on micrometric thin films. Two key parameters for tape casting are the binder relative amount and the Dr. Blade gap. The binder relative amount has a strong influence on the rheological properties for the ceramic YSZ slurry (ethanol, butanone, TEA, PVB, PEG, DEP). The coefficient K and the exponent m of the Cross model are reported to be inside the ranges 152.25-231.12 and 0.00987-0.26646 for PVB binder weight percentage concentrations between 6% and 12%. It is possible to describe the ceramic tape thickness dependence by means of a linear relation depending on the Dr. Blade gap whose linear coefficients (slope) are equal to 0.0350 and 0.2171 for green and sintered tapes respectively, with the YSZ slurry of the present work. (Author)

  1. Effect of kinesio-taping on ankle joint stability

    Directory of Open Access Journals (Sweden)

    Mervat A. Mohamed

    2016-05-01

    Full Text Available Ankle Instability is characterized by recurrent giving way and often develops after repeated lateral ankle sprains. Kinesiotape is more elastic than traditional athletic tape and is becoming increasingly popular. It is reported to decrease pain, improve muscle function, circulation and proprioception, however, research examining the effects of Kinesiotape in ankle instability is limited. The objective of this study was to determine if applying Kinesiotape to unstable ankle may improve performance in the Star Excursion Balance Test (SEBT, which has been shown to be a sensitive and reliable measure for quantifying dynamic balance. Thirty subjects with first degree ankle sprain were participated in this study. SEBT was used to test the subject dynamic balance under three conditions; without taping, with white athletic tape and with kinesiotape. One way repeated measure ANOVA using Greenhouse-Geisser corrections were conducted to evaluate differences in SEBT for the three conditions. Pairwise comparison of the outcome measures in the three occasions (without taping, with athletic taping, and with kinesio taping revealed statistically significant differences of all outcomes between occasion 1 (without taping and occasion 2 (with athletic taping favoring the athletic taping (p < 0.05. Also, a statistically significant difference between occasion 1 (without taping and occasion 3 (with kinesio taping were found (p < 0.05 favoring kinesio taping. Moreover, pairwise comparison of the ankle stability outcomes using athletic taping versus kinesio taping indicated a statistically significant difference (p < 0.05 in favor of kinesio taping measures. Conclusion: kinesiotape has superior effect than athletic tape in patients with first degree ankle sprain and can be used safely for improving ankle joint stability.

  2. Preparation of YBaCuO superconducting tape by RF magnetron sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Fukutomi, Masao; Akutsu, Nakao; Tanaka, Yoshiaki; Asano, Toshihisa; Maeda, Hiroshi (National Research Inst. for Metals, Tsukuba (Japan); Mitsui Mining and Smelting Co., Ltd., Tokyo (Japan))

    1989-04-01

    The effect of buffer layers, conditions of film preparation, and the relation between superconducting characteristics and bombardment of high energy ions on films were discussed in an attempt to fabricate YBaCuO films on metallic substrates by sputtering. Hastelloy-X tapes and Chromel (Ni-10Cr) fine wires were used as metallic substrates, and MgO films as buffer layers, which were provided by sputtering a MgO sintered target and annealing. As a result, superconducting films were favorably obtained on the Hastelloy tapes with the MgO buffer layers, however, counter diffusion at the interface of the film and layer was unavoidable in annealing. C axis-highly oriented film with high zero resistance Tc was obtained in such an arrangement of the target and substrate as to lower the effect of 0{sup {minus}} ion resputtering, resulting in the most favorable Tc=80.4K. YBaCuO superconducting films could be also deposited on a bundle of Chromel fine wires preliminarily. 11 refs., 7 figs.

  3. Ductile alloy and process for preparing composite superconducting wire

    Science.gov (United States)

    Verhoeven, J.D.; Finnemore, D.K.; Gibson, E.D.; Ostenson, J.E.

    An alloy for the commercial production of ductile superconducting wire is prepared by melting together copper and at least 15 weight percent niobium under non-oxygen-contaminating conditions, and rapidly cooling the melt to form a ductile composite consisting of discrete, randomly distributed and oriented dendritic-shaped particles of niobium in a copper matrix. As the wire is worked, the dendritic particles are realigned parallel to the longitudinal axis and when drawn form a plurality of very fine ductile superconductors in a ductile copper matrix. The drawn wire may be tin coated and wound into magnets or the like before diffusing the tin into the wire to react with the niobium. Impurities such as aluminum or gallium may be added to improve upper critical field characteristics.

  4. Seeded perturbations in wire array z-pinches

    International Nuclear Information System (INIS)

    Robinson, Allen Conrad; Kantsyrev, Victor Leonidovich; Wunsch, Scott Edward; Oliver, Bryan Velten; Lebedev, Sergey V.; Safronova, Alla S.; Maxwell, J.; McKenney, John Lee; Ampleford, David J.; Rapley, J.; Bott, S.C.; Palmer, J.B.A.; Bland, Simon Nicholas; Jones, Brent Manley; Chittenden, Jeremy Paul; Garasi, Christopher Joseph; Hall, Gareth Neville; Mehlhorn, Thomas Alan; Deeney, Christopher

    2004-01-01

    The impact of 3D structure on wire array z-pinch dynamics is a topic of current interest, and has been studied by the controlled seeding of wire perturbations. First, Al wires were etched at Sandia, creating 20% radial perturbations with variable axial wavelength. Observations of magnetic bubble formation in the etched regions during experiments on the MAGPIE accelerator are discussed and compared to 3D MHD modeling. Second, thin NaF coatings of 1 mm axial extent were deposited on Al wires and fielded on the Zebra accelerator. Little or no axial transport of the NaF spectroscopic dopant was observed in spatially resolved K-shell spectra, which places constraints on particle diffusivity in dense z-pinch plasmas. Finally, technology development for seeding perturbations is discussed

  5. Quality Designed Twin Wire Arc Spraying of Aluminum Bores

    Science.gov (United States)

    König, Johannes; Lahres, Michael; Methner, Oliver

    2015-01-01

    After 125 years of development in combustion engines, the attractiveness of these powerplants still gains a great deal of attention. The efficiency of engines has been increased continuously through numerous innovations during the last years. Especially in the field of motor engineering, consequent friction optimization leads to cost-effective fuel consumption advantages and a CO2 reduction. This is the motivation and adjusting lever of NANOSLIDE® from Mercedes-Benz. The twin wire arc-spraying process of the aluminum bore creates a thin, iron-carbon-alloyed coating which is surface-finished through honing. Due to the continuous development in engines, the coating strategies must be adapted in parallel to achieve a quality-conformed coating result. The most important factors to this end are the controlled indemnification of a minimal coating thickness and a homogeneous coating deposition of the complete bore. A specific system enables the measuring and adjusting of the part and the central plunging of the coating torch into the bore to achieve a homogeneous coating thickness. Before and after measurement of the bore diameter enables conclusions about the coating thickness. A software tool specifically developed for coating deposition can transfer this information to a model that predicts the coating deposition as a function of the coating strategy.

  6. Recent progress in methods for non-invasive measurements of local strain in practical superconducting wires and conductors using quantum beam techniques

    International Nuclear Information System (INIS)

    Osamura, Kozo; Machiya, Shutaro; Tsuchiya, Yoshinori; Suzuki, Hiroshi; Awaji, Satoshi; Takahashi, Kohki; Oguro, Hidetoshi; Harjo, Stefanus; Hemmi, Tsutomu; Nakamoto, Tatsushi; Sugano, Michinaka; Jin, Xinzhe; Kajiwara, Kentaro

    2014-01-01

    Practical superconducting wires are designed with a composite structure to meet the desired engineering characteristics by expert selection of materials and design of the architecture. In practice, the local strain exerted on the superconducting component influences the electromagnetic properties. Here, recent progress in methods used to measure the local strain in practical superconducting wires and conductors using quantum beam techniques is introduced. Recent topics on the strain dependence of critical current are reviewed for three major practical wires: ITER-Nb 3 Sn strand, DI-BSCCO wires and REBCO tapes. (author)

  7. Development of Strontium Titanate Thin films on Technical Substrates for Superconducting Coated Conductors

    DEFF Research Database (Denmark)

    Pallewatta, Pallewatta G A P; Yue, Zhao; Grivel, Jean-Claude

    2012-01-01

    SrTiO3 is a widely studied perovskite material due to its advantages as a template for high temperature superconducting tapes. Heteroepitaxial SrTiO3 thin films were deposited on Ni/W tapes using dip-coating in a precursor solution followed by drying and annealing under reducing conditions. Nearl...

  8. Coat Hangers across the Curriculum

    Science.gov (United States)

    Kibble, Bob

    2012-01-01

    There are many ways in which wire coat hangers can be used other than for suspending clothes. The author has been making use of them in his teaching for many years--copying ideas from colleagues and creating some for himself. In this article, he shares five examples that can enrich learning about science. (Contains 6 figures.)

  9. Detection of AE signals from a HTS tape during quenching in a solid cryogen-cooling system

    International Nuclear Information System (INIS)

    Kim, K.J.; Song, J.B.; Kim, J.H.; Lee, J.H.; Kim, H.M.; Kim, W.S.; Na, J.B.; Ko, T.K.; Lee, H.G.

    2010-01-01

    The acoustic emission (AE) technique is suitable for detecting the presence of thermal and mechanical stress in superconductors, which have adverse effects on the stability of their application systems. However, the detection of AE signals from a HTS tape in a bath of liquid cryogen (such as liquid nitrogen, LN 2 ) has not been reported because of its low signal to noise ratio due to the noise from the boiling liquid cryogen. In order to obtain the AE signals from the HTS tapes during quenching, this study carried out repetitive quench tests for YBCO coated conductor (CC) tapes in a cooling system using solid nitrogen (SN 2 ). This paper examined the performance of the AE sensor in terms of the amplitudes of the AE signals in the SN 2 cooling system.

  10. Irreversible properties of YBCO coated conductors

    International Nuclear Information System (INIS)

    Vostner, A.

    2001-02-01

    Over the past few years substantial efforts were made to optimize the fabrication techniques of various high temperature superconductors for commercial applications. In addition to Bi-2223 tapes, Y-123 coated conductors have the potential for large-scale production and are considered as the second generation of superconducting 'wires' for high current applications. This work reports on magnetic and transport current investigations of Y-123 thick films deposited on either single crystalline substrates by liquid phase epitaxy (LPE) or on metallic substrates by pulsed laser deposition (PLD). At the beginning, a short introduction of the general idea of a coated conductor and of the different production techniques is presented, followed by a description of the different experimental set-ups and the evaluation methods. The main part starts with the results obtained from SQUID magnetometry and ac-susceptibility measurements including the transition temperatures T c , the field dependence of the magnetic critical current densities and the irreversibility lines. In addition, some issues concerning the granular structure and the inter- and intragranular current distribution of the superconducting films are discussed. The investigations by transport currents are focused on the behavior of the application relevant irreversible parameters. These are the angular and the field dependence of the critical transport current densities at 77 and 60 K, as well as the temperature dependence of the irreversibility fields up to 6 T. To gain more insight into the defect structure of the films, neutron irradiation studies were performed on some samples. The introduction of these artificial pinning centers causes large enhancements of the magnetic J c in LPE specimens for the field parallel to the c-axis (H//c) at higher temperatures and magnetic fields. The granular structure of the samples does not change up to the highest neutron fluences. However, the enhancements of the transport J c

  11. Wire core reactor for NTP

    International Nuclear Information System (INIS)

    Harty, R.B.

    1991-01-01

    The development of the wire core system for Nuclear Thermal Propulsion (NTP) that took place from 1963 to 1965 is discussed. A wire core consists of a fuel wire with spacer wires. It's an annular flow core having a central control rod. There are actually four of these, with beryllium solid reflectors on both ends and all the way around. Much of the information on the concept is given in viewgraph form. Viewgraphs are presented on design details of the wire core, the engine design, engine weight vs. thrust, a technique used to fabricate the wire fuel element, and axial temperature distribution

  12. In-Situ Wire Damage Detection System

    Science.gov (United States)

    Williams, Martha K. (Inventor); Roberson, Luke B. (Inventor); Tate, Lanetra C. (Inventor); Smith, Trent M. (Inventor); Gibson, Tracy L. (Inventor); Jolley, Scott T. (Inventor); Medelius, Pedro J. (Inventor)

    2014-01-01

    An in-situ system for detecting damage in an electrically conductive wire. The system includes a substrate at least partially covered by a layer of electrically conductive material forming a continuous or non-continuous electrically conductive layer connected to an electrical signal generator adapted to delivering electrical signals to the electrically conductive layer. Data is received and processed to identify damage to the substrate or electrically conductive layer. The electrically conductive material may include metalized carbon fibers, a thin metal coating, a conductive polymer, carbon nanotubes, metal nanoparticles or a combination thereof.

  13. Novel Chemical Process for Producing Chrome Coated Metal

    OpenAIRE

    Pelar, Christopher; Greenaway, Karima; Zea, Hugo; Wu, Chun-Hsien; Luhrs, Claudia C.; Phillips, Jonathan

    2018-01-01

    The article of record as published may be found at http://dx.doi.org/10.3390/ma11010078 This work demonstrates that a version of the Reduction Expansion Synthesis (RES) process, Cr-RES, can create a micron scale Cr coating on an iron wire. The process involves three steps. I. A paste consisting of a physical mix of urea, chrome nitrate or chrome oxide, and water is prepared. II. An iron wire is coated by dipping. III. The coated, and dried, wire is heated to ~800 ◦C for 10 min in a tube fu...

  14. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...... new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as “wired to freedom,” we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear...

  15. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  16. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  17. EFFECT OF KINESIO TAPE VERSUS ATHLETIC TAPE ON MYOELECTRIC ACTIVITY OF ANKLE MUSCLES IN PATIENTS WITH CHRONIC ANKLE SPRAIN

    Directory of Open Access Journals (Sweden)

    Asmaa F Abdelmonem

    2018-04-01

    Full Text Available Background: Sprained ankle a common orthopedic injury. The standard treatment for ankle sprains remains nonoperative. Ankle taping was used to protect and prevent ligaments excessive strain. So, the current study aimed at investigating the effect of spa-care Kinesio tape versus standard white athletic tape on myoelectric activities (EMG of ankle evertors (peroneus longus and invertors (tibialis anterior in a chronic ankle sprain. Methods: A convenient sample of 30 patients with a chronic ankle sprain (18 females and 12 males were included in this study. Their mean age ±SD was 24 ±1.2 years. Their height was 175±4.8 cm among men & 163±5.2 cm for females, and weight was 85±5.2 kg for males & 74±5.5 kg for women. It was a within-group design in which the same participant experienced the two types of taping compared to no taping condition. Root mean square (RMS was measured while participants were moving the isokinetic dynamometer at an angular velocity of 120°/sec using concentric contraction mode through full ankle range of motion. The EMG (RMS of evertors and invertors was measured immediately after the three taping ways (no tape, Kinesio tape, and athletic tape with a one-week interval between each taping. Results: Spa-care Kinesiotape significantly reduced evertors and invertors EMG (RMS compared with no tape or athletic tape in patients with chronic ankle sprain. Mean± SD of the evertors was 0.7 (±0.1 for no tape and 0.58 (±0.2 for Kinesio tape. The P value was 0.000 for kinesio tape in evertors compared with no tape. Also, mean± SD of the invertors was 0.87 (±0.23 for no tape, and 0.54 (±0.1 for Kinesio tape and the P value was 0.001 for Kinesio tape in invertors compared with no tape. Conclusion: Spa-care Kinesio tape may be useful for reducing EMG activity of ankle muscles in a chronic ankle sprain.

  18. Methods and systems for fabricating high quality superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Majkic, Goran; Selvamanickam, Venkat

    2018-02-13

    An MOCVD system fabricates high quality superconductor tapes with variable thicknesses. The MOCVD system can include a gas flow chamber between two parallel channels in a housing. A substrate tape is heated and then passed through the MOCVD housing such that the gas flow is perpendicular to the tape's surface. Precursors are injected into the gas flow for deposition on the substrate tape. In this way, superconductor tapes can be fabricated with variable thicknesses, uniform precursor deposition, and high critical current densities.

  19. Experimental Tape Casting of Adjacently Graded Materials for Magnetic Refrigeration

    DEFF Research Database (Denmark)

    Bulatova, Regina

    encompass modification of the entire tape caster into a multi chamber unit, establishment of the optimal operating parameters such as casting gap, speed, and slurry level in the tape caster reservoir, and elucidation of the impact of chamber partition design on the quality of the final tape. The second...... of the side-by-side tape casting technique: recognising critical parameters which affect the quality of a graded tape, shape and position of the interface area. Studied parameters can be divided into two categories: operational parameters and slurry formulation optimisation. The operational parameters...

  20. Transmission electron microscopy investigation of Bi-2223/Ag tapes

    DEFF Research Database (Denmark)

    Andersen, L.G.; Bals, S.; Tendeloo, G. Van

    2001-01-01

    during the tape processing, (3) a study of the grain boundaries on an atomic scale, including intergrowth investigations. Tapes with different process parameters have been compared with respect to the microstructure. A fully processed tape has on the average 50% thicker Bi-2223 grains than a tape after......The microstructure of (Bi,Pb)(2)Sr2Ca2CuOx (Bi-2223) tapes has been investigated by means of transmission electron microscopy (TEM) and high-resolution TEM. The emphasis has been placed on: (1) an examination of the grain morphology and size, (2) grain and colony boundary angles, which are formed...

  1. Method of forming a ceramic superconducting composite wire using a molten pool

    International Nuclear Information System (INIS)

    Geballe, T.H.; Feigelson, R.S.; Gazit, D.

    1991-01-01

    This paper describes a method for making a flexible superconductive composite wire. It comprises: drawing a wire of noble metal through a molten material, formed by melting a solid formed by pressing powdered Bi 2 O 3 , CaCO 3 SrCO 3 and CuO in a ratio of components necessary for forming a Bi-Sr-Ca-Cu-O superconductor, into the solid and sintering at a temperature in the range of 750 degrees - 800 degrees C. for 10-20 hours, whereby the wire is coated by the molten material; and cooling the coated wire to solidify the molten material to form the superconductive flexible composite wire without need of further annealing

  2. Adhesion and corrosion studies of a lithium based conversion coating film on the 2024 aluminum alloy

    International Nuclear Information System (INIS)

    Castro, M.R.S.; Nogueira, J.C.; Thim, G.P.; Oliveira, M.A.S.

    2004-01-01

    AA2024-T3-aluminum alloy surfaces were coated using non-chromate and chromate conversion coatings. All coatings were painted with the 10P4-2-primer epoxy resin. Independent on the film formation process, films passed on the substrate/conversion coating wet tape adhesion test. However, only the chromate conversion coating passed on the conversion coating/primer epoxy resin adhesion test. Electrochemical corrosion measurements showed that non-chromate conversion coated surfaces present lower corrosion current density, bigger polarization resistance and less negative corrosion potential than chromate conversion coated surfaces

  3. Use of video taping during simulator training

    International Nuclear Information System (INIS)

    Helton, M.; Young, P.

    1987-01-01

    The use of a video camera for training is not a new idea and is used throughout the country for training in such areas as computers, car repair, music and even in such non-technical areas as fishing. Reviewing a taped simulator training session will aid the student in his job performance regardless of the position he holds in his organization. If the student is to be examined on simulator performance, video will aid in this training in many different ways

  4. The four silo STK Powderhorn Tape Library

    CERN Multimedia

    Patrice Loïez

    2001-01-01

    A view of the four silo Storage Tek (STK) Powderhorn Tape Library and its control area. Each silo can contain up to 6000 storage slots with cartridges of 10, 20, 25 or 50 GB capacity, reaching a data transfer rate of up to 12 Mbytes/sec. This will form part of the Grid system that will process the huge amounts of data produced at the LHC.

  5. Estimation of hysteretic losses for MgB2 tapes under the operating conditions of a generator

    International Nuclear Information System (INIS)

    Vargas-Llanos, Carlos Roberto; Zermeño, Víctor M R; Grilli, Francesco; Sanz, Santiago; Trillaud, Frederic

    2016-01-01

    Hysteretic losses in the MgB 2 wound superconducting coils of a 550 kW synchronous hybrid scaled generator were estimated as part of the European project SUPRAPOWER led by the Spanish Fundación Tecnalia Research and Innovation. Particular interest was given to the losses caused by the magnetic flux ripples in the rotor coils originating from the conventional stator during nominal operation. To compute these losses, a 2D finite element analysis was conducted and Maxwell’s equations written in the H-formulation were solved considering the nonlinear material properties of the conductor materials. The modeled tapes are made of multiple MgB 2 filaments embedded in a Ni matrix and soldered to a high purity copper strip and insulated with Dacron braid. Three geometrical models of single tape cross sections of decreasing complexity were studied: (1) the first model reproduced closely the actual cross section obtained from tape micrographs. (2) The second model was obtained from the computed elasto-plastic deformation of a round Ni wire. (3) The third model was based on a simplified cross section with the superconducting filaments bundled in a single elliptical bulky structure. The last geometry allowed the validation of the modeling technique by comparing numerical losses with results from well-established analytical expressions. Additionally, the following cases of filament transpositions of the multi-filamentary tape were studied: no transposition, partial and full transposition; thereby improving understanding of the relevance of the tape fabrication process on the magnitude of the determination of ac losses. Finally, choosing the right level of geometrical detail, the following operational regimes of the machine and its impact on individual superconducting tape losses in the rotor were studied: bias-dc current, ramping current under ramping background field and magnetic flux ripples under dc background current and field. (paper)

  6. Estimation of hysteretic losses for MgB2 tapes under the operating conditions of a generator

    Science.gov (United States)

    Vargas-Llanos, Carlos Roberto; Zermeño, Víctor M. R.; Sanz, Santiago; Trillaud, Frederic; Grilli, Francesco

    2016-03-01

    Hysteretic losses in the MgB2 wound superconducting coils of a 550 kW synchronous hybrid scaled generator were estimated as part of the European project SUPRAPOWER led by the Spanish Fundación Tecnalia Research & Innovation. Particular interest was given to the losses caused by the magnetic flux ripples in the rotor coils originating from the conventional stator during nominal operation. To compute these losses, a 2D finite element analysis was conducted and Maxwell’s equations written in the H-formulation were solved considering the nonlinear material properties of the conductor materials. The modeled tapes are made of multiple MgB2 filaments embedded in a Ni matrix and soldered to a high purity copper strip and insulated with Dacron braid. Three geometrical models of single tape cross sections of decreasing complexity were studied: (1) the first model reproduced closely the actual cross section obtained from tape micrographs. (2) The second model was obtained from the computed elasto-plastic deformation of a round Ni wire. (3) The third model was based on a simplified cross section with the superconducting filaments bundled in a single elliptical bulky structure. The last geometry allowed the validation of the modeling technique by comparing numerical losses with results from well-established analytical expressions. Additionally, the following cases of filament transpositions of the multi-filamentary tape were studied: no transposition, partial and full transposition; thereby improving understanding of the relevance of the tape fabrication process on the magnitude of the determination of ac losses. Finally, choosing the right level of geometrical detail, the following operational regimes of the machine and its impact on individual superconducting tape losses in the rotor were studied: bias-dc current, ramping current under ramping background field and magnetic flux ripples under dc background current and field.

  7. Perceived Organizational Red Tape and Organizational Performance in Public Services

    DEFF Research Database (Denmark)

    Jacobsen, Christian Bøtcher; Jakobsen, Mads Leth

    2018-01-01

    The claim that perceived organizational red tape hampers public services has become a central theme in public administration research. Surprisingly, however, few scholars have empirically examined the impact of perceived red tape on organizational performance. This study empirically analyzes how...... perceived organizational red tape among managers and frontline staff relates to objectively measured performance. The data consists of survey responses from teachers and principals at Danish upper secondary schools combined with grade-level administrative performance data. Based on theories of red tape...... and motivation crowding, we hypothesize that perceived organizational red tape reduces performance within such organizations. The empirical result is a small, negative relationship between staff perception of red tape and performance, and no relationship between manager-perceived red tape and performance....

  8. Transaction aware tape-infrastructure monitoring

    International Nuclear Information System (INIS)

    Nikolaidis, Fotios; Kruse, Daniele Francesco

    2014-01-01

    Administrating a large scale, multi protocol, hierarchical tape infrastructure like the CERN Advanced STORage manager (CASTOR)[2], which stores now 100 PB (with an increasing step of 25 PB per year), requires an adequate monitoring system for quick spotting of malfunctions, easier debugging and on demand report generation. The main challenges for such system are: to cope with CASTOR's log format diversity and its information scattered among several log files, the need for long term information archival, the strict reliability requirements and the group based GUI visualization. For this purpose, we have designed, developed and deployed a centralized system consisting of four independent layers: the Log Transfer layer for collecting log lines from all tape servers to a single aggregation server, the Data Mining layer for combining log data into transaction context, the Storage layer for archiving the resulting transactions and finally the Web UI layer for accessing the information. Having flexibility, extensibility and maintainability in mind, each layer is designed to work as a message broker for the next layer, providing a clean and generic interface while ensuring consistency, redundancy and ultimately fault tolerance. This system unifies information previously dispersed over several monitoring tools into a single user interface, using Splunk, which also allows us to provide information visualization based on access control lists (ACL). Since its deployment, it has been successfully used by CASTOR tape operators for quick overview of transactions, performance evaluation, malfunction detection and from managers for report generation.

  9. AC Loss Reduction in Filamentized YBCO Coated Conductors with Virtual Transverse Cross-cuts

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Yifei [ORNL; Duckworth, Robert C [ORNL; Ha, Tam T [ORNL; List III, Frederick Alyious [ORNL; Gouge, Michael J [ORNL; Chen, Y [SuperPower Incorporated, Schenectady, New York; X, Xiong, [SuperPower Incorporated, Schenectady, New York; Selvamanickam, V. [SuperPower Incorporated, Schenectady, New York

    2011-01-01

    While the performance of YBa{sub 2}Cu{sub 3}O{sub 7-x} (YBCO)-based coated conductors under dc currents has improved significantly in recent years, filamentization is being investigated as a technique to reduce ac loss so that the 2nd generation (2G) high temperature superconducting (HTS) wires can also be utilized in various ac power applications such as cables, transformers and fault current limiters. Experimental studies have shown that simply filamentizing the superconducting layer is not effective enough to reduce ac loss because of incomplete flux penetration in between the filaments as the length of the tape increases. To introduce flux penetration in between the filaments more uniformly and further reduce the ac loss, virtual transverse cross-cuts were made in superconducting filaments of the coated conductors fabricated using the metal organic chemical vapor deposition (MOCVD) method. The virtual transverse cross-cuts were formed by making cross-cuts (17 - 120 {micro}m wide) on the IBAD (ion beam assisted deposition)-MgO templates using laser scribing followed by depositing the superconducting layer ({approx} 0.6 {micro}m thick). AC losses were measured and compared for filamentized conductors with and without the cross-cuts under applied peak ac fields up to 100 mT. The results were analyzed to evaluate the efficacy of filament decoupling and the feasibility of using this method to achieve ac loss reduction.

  10. Wired vs. Wireless.

    Science.gov (United States)

    Fielding, Randall

    2000-01-01

    Presents a debate on which technology will be in tomorrow's classrooms and the pros and cons of wiring classrooms and using a wireless network. Concluding comments address the likelihood, and desirability, of placing computers throughout the entire educational process and what types of computers and capabilities are needed. (GR)

  11. A World without Wires

    Science.gov (United States)

    Panettieri, Joseph C.

    2006-01-01

    The wireless bandwagon is rolling across Mississippi, picking up a fresh load of converts and turning calamity into opportunity. Traditional wired school networks, many of which unraveled during Hurricane Katrina, are giving way to advanced wireless mesh networks that frequently include voice-over-IP (VoIP) capabilities. Vendor funding is helping…

  12. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and have...

  13. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  14. Enhancing the low-level tape layer of CERN Tape Archive software

    CERN Document Server

    AUTHOR|(CDS)2160814; Ruse, Laura Cristina; Vasilescu, Laura

    CERN manages the largest scientific data archive in the HEP domain. The archive currently holds over 180 Petabytes, with forecasts of up to 100PB of new data added per year. Considering this numbers, the most cost-effective solution for storage in terms of capacity and maintenance is represented by magnetic tapes. The drawback of this solution is the access time which can raise to several minutes for a series of files. In an environment where very large volumes of physics data are being traded from tape to disk and vice versa, this issue becomes a serious performance bottleneck. This thesis introduces two low-level tape access optimizations: first, adding support for the Recommended Access Order (RAO), a mechanism offered by the tape hardware infrastructure to compute the file order corresponding to the minimum access time. We will present our solution for including RAO in the file retrieval operations in CERN tape archive software in order to benefit from the reduced reading time. The second optimization ...

  15. Wire EDM for Refractory Materials

    Science.gov (United States)

    Zellars, G. R.; Harris, F. E.; Lowell, C. E.; Pollman, W. M.; Rys, V. J.; Wills, R. J.

    1982-01-01

    In an attempt to reduce fabrication time and costs, Wire Electrical Discharge Machine (Wire EDM) method was investigated as tool for fabricating matched blade roots and disk slots. Eight high-strength nickel-base superalloys were used. Computer-controlled Wire EDM technique provided high quality surfaces with excellent dimensional tolerances. Wire EDM method offers potential for substantial reductions in fabrication costs for "hard to machine" alloys and electrically conductive materials in specific high-precision applications.

  16. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  17. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  18. Anisotropy of critical current density in the superconducting Nb/sub 3/Sn tape wires

    Energy Technology Data Exchange (ETDEWEB)

    Glowacki, B A [Technical Univ., Wroclaw (Poland). Inst. of Fundamental Electrotechnics and Electrotechnology

    1985-04-01

    In this letter the results are presented of an investigation of Isub(c parallel) and Isub(c perpendicular) in Nb/sub 3/Sn layers obtained in the process diffusion of tin atoms from liquid bronze solution Cu-80% Sn to the Nb-1.5% Zr substrate. Measurements of critical current density in Nb/sub 3/Sn layers were carried out in a perpendicular magnetic field of the induction value 4.25 T for different sample surface orientations in relation to the magnetic field strength vector defined by the value of angle. The critical current density was measured at a temperature of 4.2 K. Phase identification and investigation of the microstructure of superconducting Nb-Sn layers were performed on the Moessbauer spectrometer and scanning electron microscope, respectively. Classification measurements of grains in Nb-Sn layers were carried out with TV automatic image analyser. The texture and lattice parameter in Nb/sub 3/Sn layers were investigated by means of an X-ray diffractometer. The surface zone of Nb/sub 3/Sn layer was removed with the use of an argon ion gun. Results are presented and discussed.

  19. Transobturator tapes are preferable over transvaginal tapes for the management of female stress urinary incontinence: Against

    Directory of Open Access Journals (Sweden)

    Arun Chawla

    2009-01-01

    Full Text Available Midurethral placement of tension-free vaginal tapes with a transvaginal route for stress urinary incontinence achieves higher and better long-term success rates than the transobturator route. Bladder perforations are reported more in transvaginal tape (TVT but incidences of vaginal erosions, extrusion, and groin pain are exceedingly more in TOT groups. There is no clear evidence that transobturator tape (TOT is associated with less post-operative voiding problems than TVT. Major complications such as bowel injuries and significant vascular injuries with TVT are rare. TVT has been found to be superior to TOT and preferable in technically demanding conditions such as prior anti-incontinence operation failures, obese women, and very elevated and scarred lateral cul-de sac. TVT is always preferred in severe grades of stress urinary incontinence and with patients of intrinsic sphincter deficiency (ISD with little or no urethral mobility.

  20. Current status of high-T{sub c} wire

    Energy Technology Data Exchange (ETDEWEB)

    Vase, Per [Nordic Superconductor Technologies A/S, Priorparken 685, DK 2605 Broendby (Denmark); Fluekiger, Rene [Departement de Physique de la Matiere Condensee, Universite de Geneve (Switzerland); Leghissa, Martino [Siemens AG, Corporate Technology, Erlangen (Germany); Glowacki, Bartek [Department of Material Science and Metallurgy, University of Cambridge, Cambridge CB2 3QZ (United Kingdom)

    2000-07-01

    This paper is the result of the work of a SCENET (The European Network for Superconductivity) material working group's efforts on giving values for present and future expected performance of high-temperature superconducting (HTS) wires and tapes. The purpose of the work is to give input to the design of HTS applications like power cables, motors, current leads, magnets, transformers and generators. The current status performance values are supposed to be used in the design of today's prototypes and the future values for the design of fully commercial HTS applications of the future. We focus on what is expected to be the relevant parameters for HTS application design. The most successful technique by far for making HTS tapes has been on the (Bi, Pb){sub 2}Sr{sub 2}Ca{sub 2}Cu{sub 3}O{sub x} (Bi-2223) material by the powder-in-tube (PIT) technique and this paper therefore focuses on giving the current status and expected future performance for Bi-2223 tapes. (author)

  1. Mechanical properties and bending strain effect on Cu-Ni sheathed MgB2 superconducting tape

    International Nuclear Information System (INIS)

    Fu, Minyi; Chen, Jiangxing; Jiao, Zhengkuan; Kumakura, H.; Togano, K.; Ding, Liren; Zhang, Yong; Chen, Zhiyou; Han, Hanmin; Chen, Jinglin

    2004-01-01

    The Young's modulus (E) of Cu-Ni sheathed MgB 2 monofilament tape was measured using electric method. It is about 8.05 x 10 10 Pa, the same order of Cu and its alloys. We found that the lower E value of the MgB 2 component seemed to relate to the lower filament density. The benefits of pre-compression in filaments were discussed in terms of improving stress distribution in the wires and tapes during winding and operation of superconducting magnets. The magnetic field dependence of J c was investigated on the sample subjected to various strain levels through bending with different radii at 4.2 K

  2. Self-supported carbon electrodes obtained by tape casting

    Directory of Open Access Journals (Sweden)

    Rubio-Marcos, F.

    2006-06-01

    Full Text Available This paper describes the preparation and electrochemical response of self-supported carbon electrodes prepared by tape casting. The dc electrical conductivity, σ, of the electrodes was determined by four-wire resistance measurements and a relation between the graphite/organic additives ratio and the electrical conductivity was established. The application of these self-supported carbon electrodes as working electrodes in analytical techniques was also evaluated using norepinephrine as electroactive substance in cyclic voltammetry and chronoamperometry. The results were compared with the traditional electrodes, carbon paste electrodes (CPEs, showing that the new self-supported carbon electrodes had both lower background noise and higher analytical response.

    Este artículo describe la preparación y respuesta electroquímica de electrodos de carbono autosoportados preparados mediante colado en cinta. La conductividad eléctrica en corriente continua de este nuevo tipo de electrodos de carbono se ha determinado usando el método de cuatro puntas y se ha establecido una relación ente la relación grafito/aditivos orgánicos y la conductividad eléctrica. La aplicación de estos electrodos autosoportados como electrodos de trabajo en diversas técnicas electroanalíticas también se ha evaluado, empleando norepinefrina como analito en voltametría cíclica y en cronoamperometría. Los resultados se compararon con los obtenidos empleando los electrodos de pasta de carbono tradicionales como electrodos de trabajo, viéndose que la señal de los nuevos electrodos autosoportados poseía menor ruido de fondo y mayor respuesta analítica.

  3. High-performance, stretchable, wire-shaped supercapacitors.

    Science.gov (United States)

    Chen, Tao; Hao, Rui; Peng, Huisheng; Dai, Liming

    2015-01-07

    A general approach toward extremely stretchable and highly conductive electrodes was developed. The method involves wrapping a continuous carbon nanotube (CNT) thin film around pre-stretched elastic wires, from which high-performance, stretchable wire-shaped supercapacitors were fabricated. The supercapacitors were made by twisting two such CNT-wrapped elastic wires, pre-coated with poly(vinyl alcohol)/H3PO4 hydrogel, as the electrolyte and separator. The resultant wire-shaped supercapacitors exhibited an extremely high elasticity of up to 350% strain with a high device capacitance up to 30.7 F g(-1), which is two times that of the state-of-the-art stretchable supercapacitor under only 100% strain. The wire-shaped structure facilitated the integration of multiple supercapacitors into a single wire device to meet specific energy and power needs for various potential applications. These supercapacitors can be repeatedly stretched from 0 to 200% strain for hundreds of cycles with no change in performance, thus outperforming all the reported state-of-the-art stretchable electronics. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Use of binaural beat tapes for treatment of anxiety: a pilot study of tape preference and outcomes.

    Science.gov (United States)

    Le Scouarnec, R P; Poirier, R M; Owens, J E; Gauthier, J; Taylor, A G; Foresman, P A

    2001-01-01

    Recent studies and anecdotal reports suggest that binaural auditory beats can affect mood, performance on vigilance tasks, and anxiety. To determine whether mildly anxious people would report decreased anxiety after listening daily for 1 month to tapes imbedded with tones that create binaural beats, and whether they would show a definite tape preference among 3 tapes. A 1-group pre-posttest pilot study. Patients' homes. A volunteer sample of 15 mildly anxious patients seen in the Clinique Psyché, Montreal, Quebec. Participants were asked to listen at least 5 times weekly for 4 weeks to 1 or more of 3 music tapes containing tones that produce binaural beats in the electroencephalogram delta/theta frequency range. Participants also were asked to record tape usage, tape preference, and anxiety ratings in a journal before and after listening to the tape or tapes. Anxiety ratings before and after tape listening, pre- and post-study State-Trait Anxiety Inventory scores, and tape preferences documented in daily journals. Listening to the binaural beat tapes resulted in a significant reduction in the anxiety score reported daily in patients' diaries. The number of times participants listened to the tapes in 4 weeks ranged from 10 to 17 (an average of 1.4 to 2.4 times per week) for approximately 30 minutes per session. End-of-study tape preferences indicated that slightly more participants preferred tape B, with its pronounced and extended patterns of binaural beats, over tapes A and C. Changes in pre- and posttest listening State-Trait Anxiety Inventory scores trended toward a reduction of anxiety, but these differences were not statistically significant. Listening to binaural beat tapes in the delta/theta electroencephalogram range may be beneficial in reducing mild anxiety. Future studies should account for music preference among participants and include age as a factor in outcomes, incentives to foster tape listening, and a physiologic measure of anxiety reduction. A

  5. Development and manufacturing of tape casted, anode-supported solid oxide fuel cells; Entwicklung und Herstellung von foliengegossenen, anodengestuetzten Festoxidbrennstoffzellen

    Energy Technology Data Exchange (ETDEWEB)

    Schafbauer, Wolfgang

    2010-07-01

    Solid oxide fuel cells offer high potential in transforming the chemical energy of hydrogen or natural gas into electrical energy. Due to the high efficiency of fuel cells, lots of effort has been made in the improvement of net efficiency and in materials development during the last years. Recently, the introduction of high performance, low-cost production technologies become more and more important. At the Institute of Energy Research IEF-1 of Forschungszentrum Julich, standard SOFCs were processed by time and work consuming methods. On the way to market entrance, product costs have to be reduced drastically. The aim of this thesis is the introduction of a high efficient low-cost processing route for the SOFC manufacturing. Therefore, the well-known and well established shaping technology tape casting was used for generating the anode substrates. As the first goal of this approach, two different tape casting slurries were developed in order to get substrates in the thickness range from 300 to 500 {mu}m after sintering. After shaping of the substrates, sinter regimes for the different necessary coatings were adapted to the novel substrate types in order to obtain cells with high performance and strength. Therefore, the different coating technologies like screen printing and vacuum slip casting were used for cell manufacturing. The optimization of the different coating steps during cell manufacturing led to high performance SOFCs with a 10% higher power output compared to the Julich state-of-the-art SOFC. Additional experiments verified the workability of the novel tape cast substrates for the manufacturing of near-net-shape SOFC. Finally, the novel cell types based on tape cast substrates were assembled to stacks with up to ten repeating units. Stack tests showed identical performance and degradation compared to stacks containing state-of-the-art SOFCs. Thus, the complete lifetime circle of a SOFC starting from powder preparation to stack assembly has been

  6. Critical state instability in Nb-clad MgB2 superconducting wires

    International Nuclear Information System (INIS)

    Beilin, V.; Felner, I.; Tsindlekht, M.I.; Dul'kin, E.; Mojaev, E.; Roth, M.

    2008-01-01

    Magnetization hysteresis loops of Cu/MgB 2 , Nb/MgB 2 , Cu/Nb/MgB 2 and Fe/Cu/MgB 2 wires in parallel magnetic fields of up to 5 T were studied in the temperature range from 5 to 35 K. All Nb-clad samples exhibited a thermomagnetic instability (TMI) in the form of magnetization jumps. In a thick wire (about 2 mm in core diameter), the TMI persisted up to the unexpectedly high temperature of 32 K. Thin wires showed low TMI which vanished at T > 10 K. Cu/MgB 2 wires which did not contain a Nb barrier, showed no signs of TMI. The TMI in thin wires exhibited good reproducibility and stability in the jump pattern (JP) (jump amplitudes and positions), while thick wires showed the worst time stability. We found that moderate flat rolling of the round unstable Cu/Nb/MgB 2 wire resulted in negligible TMI at 5 K in the processed flat tape. The TMI amplitudes of studied samples correlated with the adiabatic stability parameter, β -1

  7. Effects of a paraspinal-lumbar tape application during 7 days on the perceived area of tape contact.

    Science.gov (United States)

    Funk, Stefan; Finke, Roy; Zeh, Stefan; Siebert, Tobias; Puta, Christian

    2017-05-01

    The study aimed to investigate the changes of the perceived area of tape contact during a lumbar tape application that lasted 7 days. Single group, repeated measures study. University research laboratory. Twenty-three healthy collegiate students in sports science. Perceived area of tape contact was collected by preparing a drawing of their individual perceived tape outline into a printed body image. Measurements were obtained immediately after fixation of the tape (day 0), at day 3 and day 7 during application and 5 min after the release of the application (day 7). There was no significant change of the perceived area of tape contact after 3 days of tape application. A significant decrease in the perceived area of tape contact was detected 7 days after application (p area of tape contact of healthy sport students is decreased at 7 days. This effect could not be observed at 3 days. These results provide relevant information for the use of elastic tapes concerning the duration of application in medical therapy. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Effects of Kinesio Taping versus McConnell Taping for Patellofemoral Pain Syndrome: A Systematic Review and Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Wen-Dien Chang

    2015-01-01

    Full Text Available Objectives. To conduct a systematic review comparing the effects of Kinesio taping with McConnell taping as a method of conservative management of patients with patellofemoral pain syndrome (PFPS. Methods. MEDLINE, PUBMED, EMBASE, AMED, and the Cochrane Central Register of Control Trials electronic databases were searched through July 2014. Controlled studies evaluating the effects of Kinesio or McConnell taping in PFPS patients were retrieved. Results. Ninety-one articles were selected from the articles that were retrieved from the databases, and 11 articles were included in the analysis. The methods, evaluations, and results of the articles were collected, and the outcomes of patellar tapings were analyzed. Kinesio taping can reduce pain and increase the muscular flexibility of PFPS patients, and McConnell taping also had effect in pain relief and patellar alignment. Meta-analysis showed small effect in pain reduction and motor function improvement and moderate effect in muscle activity change among PFPS patients using Kinesio taping. Conclusions. Kinesio taping technique used for muscles can relieve pain but cannot change patellar alignment, unlike McConnell taping. Both patellar tapings are used differently for PFPS patients and substantially improve muscle activity, motor function, and quality of life.

  9. APPLICATION OF THE X-RAY STRUCTURE ANALYSIS FOR IMPROVEMENT OF TECHNOLOGICAL PROCES- SES OF WIRE PRODUCTION AT BMZ

    Directory of Open Access Journals (Sweden)

    D. V. Kuznetsov

    2012-01-01

    Full Text Available The X-ray diffraction methods of qualitative and quantative analysis of phase composition of the brass coating, scale on the surface of brass wire, rod, patented wire, methods of determining the characteristics of the microstrains the lattice ferritic matrix pearlitic high-carbon steel, are explored.

  10. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  11. The Micro Wire Detector

    International Nuclear Information System (INIS)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M.; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C.

    1999-01-01

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 μm 2 apertures, crossed by 25 μm anode strips to which it is attached by 50 μm kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  12. Twisting wire scanner

    Energy Technology Data Exchange (ETDEWEB)

    Gharibyan, V.; Delfs, A.; Koruptchenkov, I.; Noelle, D.; Tiessen, H.; Werner, M.; Wittenburg, K.

    2012-11-15

    A new type of 'two-in-one' wire scanner is proposed. Recent advances in linear motors' technology make it possible to combine translational and rotational movements. This will allow to scan the beam in two perpendicular directions using a single driving motor and a special fork attached to it. Vertical or horizontal mounting will help to escape problems associated with the 45 deg scanners. Test results of the translational part with linear motors is presented.

  13. Twisting wire scanner

    International Nuclear Information System (INIS)

    Gharibyan, V.; Delfs, A.; Koruptchenkov, I.; Noelle, D.; Tiessen, H.; Werner, M.; Wittenburg, K.

    2012-11-01

    A new type of 'two-in-one' wire scanner is proposed. Recent advances in linear motors' technology make it possible to combine translational and rotational movements. This will allow to scan the beam in two perpendicular directions using a single driving motor and a special fork attached to it. Vertical or horizontal mounting will help to escape problems associated with the 45 deg scanners. Test results of the translational part with linear motors is presented.

  14. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  15. Efeitos do Kinesio Taping no Desporto

    OpenAIRE

    Pereira, Marcelo

    2012-01-01

    Trabalho apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Licenciado em Fisioterapia O médico japonês, Dr. Kenzo Kase criou, em 1973, o kinesio taping, uma nova aplicação de ligadura adesiva, tendo como objectivo melhorar a função da musculatura, sem limitar os movimentos, reduzir a dor, edema e os espasmos musculares. Parece ter também a capacidade de prevenir lesões no desporto, sendo por isso uma técnica comummente utilizada para este efeito....

  16. StorageTek T10000 Tape Cartridge

    CERN Multimedia

    1985-01-01

    Oracle StorageTek T10000T2 cartridge has total capacity of 5 TB. It is actually manufactured by Fuji Film, uses Barium Ferrite (BaFe) particles technology data store, but is also equipped with RFID chip. There is over 1 km of tape inside of the cartridge with 3584 data tracks and it supports over 25000 load/unload cycles. The archival life is estimated to be around 30 years and uncorrected bit error rate is 10-19. CERN however usually migrates data to newer technologies roughly every 5 years in order to keep the footprint under control.

  17. Information retrieval system based on INIS tapes

    International Nuclear Information System (INIS)

    Pultorak, G.

    1976-01-01

    An information retrieval system based on the INIS computer tapes is described. It includes the three main elements of a computerized information system: a data base on a machine -readable medium, a collection of queries which represent the information needs from the data - base, and a set of programs by which the actual retrieval is done, according to the user's queries. The system is built for the center's computer, a CDC 3600, and its special features characterize, to a certain degree, the structure of the programs. (author)

  18. Design of double tape recorder data acquisition system

    International Nuclear Information System (INIS)

    Guo Tianrui; Du Yifei

    1995-01-01

    In the data acquisition system supported by the microcomputer tape recorder, as the acquisition speed is often limited by the low speed of tape recorder, so a double tape recorder system is designed. In this system, two tape recorders are used in on-line acquisition system simultaneously. One DMA channel used is one designed for soft disk driver, another DMA channel used is one retained for user. By this way, the speed of tape writing could be increased to nearly twice as much. In order to prevent the data confusion, the authors open two data buffers in system and write different mark in each buffer, then write the data block to two tape recorders according to the mark. The system complies with the principle: 'Double write, Double read'

  19. Methods of Measuring Stress Relaxation in Composite Tape Springs

    Science.gov (United States)

    2015-03-26

    10 3. Cure Cycle Recommended for Patz F7 Prepreg . . . . . . . . . . . . . . . . . . . . . 17 4. Typical Stress...unique and dimensionally complex parts. Hand lay-up is the method by which prepreg tape or fibers are laid down and then the matrix is then ‘painted’ on...structure. Hand lay-up using a prepreg tape stands out as the inexpensive choice for the unique low number production of tape springs and should

  20. Tape-cast sensors and method of making

    Science.gov (United States)

    Mukundan, Rangachary [Santa Fe, NM; Brosha, Eric L [Los Alamos, NM; Garzon, Fernando H [Santa Fe, NM

    2009-08-18

    A method of making electrochemical sensors in which an electrolyte material is cast into a tape. Prefabricated electrodes are then partially embedded between two wet layers of the electrolyte tape to form a green sensor, and the green sensor is then heated to sinter the electrolyte tape around the electrodes. The resulting sensors can be used in applications such as, but not limited to, combustion control, environmental monitoring, and explosive detection. A electrochemical sensor formed by the tape-casting method is also disclosed.

  1. Molten carbonate fuel cell integral matrix tape and bubble barrier

    International Nuclear Information System (INIS)

    Reiser, C.A.; Maricle, D.L.

    1983-01-01

    A molten carbonate fuel cell matrix material is described made up of a matrix tape portion and a bubble barrier portion. The matrix tape portion comprises particles inert to molten carbonate electrolyte, ceramic particles and a polymeric binder, the matrix tape being flexible, pliable and having rubber-like compliance at room temperature. The bubble barrier is a solid material having fine porosity preferably being bonded to the matrix tape. In operation in a fuel cell, the polymer binder burns off leaving the matrix and bubble barrier providing superior sealing, stability and performance properties to the fuel cell stack

  2. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  3. Nonlinear Model of Tape Wound Core Transformers

    Directory of Open Access Journals (Sweden)

    A. Vahedi

    2015-03-01

    Full Text Available Recently, tape wound cores due to their excellent magnetic properties, are widely used in different types of transformers. Performance prediction of these transformers needs an accurate model with ability to determine flux distribution within the core and magnetic loss. Spiral structure of tape wound cores affects the flux distribution and always cause complication of analysis. In this paper, a model based on reluctance networks method is presented for analysis of magnetic flux in wound cores. Using this model, distribution of longitudinal and transverse fluxes within the core can be determined. To consider the nonlinearity of the core, a dynamic hysteresis model is included in the presented model. Having flux density in different points of the core, magnetic losses can be calculated. To evaluate the validity of the model, results are compared with 2-D FEM simulations. In addition, a transformer designed for series-resonant converter and simulation results are compared with experimental measurements. Comparisons show accuracy of the model besides simplicity and fast convergence

  4. Gaseous discharge display panel including pilot electrodes and radioactive wire

    International Nuclear Information System (INIS)

    Edwards, R.J.; Hairabedian, B.Z.; Poley, N.M.

    1975-01-01

    In a plasma display panel consisting of gas enclosed between adjacent insulating members, a light source is used to supply charged particles in the gas to permit firing of the gas when coordinate conductors identifying a site location are energized. The use of such pilot lamps facilitates ignition in firing with uniform selection and firing potentials within all sites of the display panel. To eliminate the difficulty in achieving firing during cold starts a radioactive source comprised of a copper wire electroplated with nickel 63 and overcoated with a protective coat of nickel is placed within the gas panel to provide a source of free electrons. The wire is held in place by friction against the inside walls of the panel. Since the wire emits only beta radiation, no radiation hazard exists externally to the panel

  5. Magnetoresistance peculiarities of bismuth wires in high magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Condrea, E., E-mail: condrea@nano.asm.md [Institute of Electronic Engineering and Nanotechnologies, Academy of Science of Moldova, 2028 Chisinau, Republic of Moldova (Moldova, Republic of); International Laboratory of High Magnetic Fields and Low Temperatures, Gajowicka 95, 51-421 Wroclaw (Poland); Gilewski, A. [International Laboratory of High Magnetic Fields and Low Temperatures, Gajowicka 95, 51-421 Wroclaw (Poland); MagNet, 50-421 Wroclaw (Poland); Nicorici, A. [Institute of Electronic Engineering and Nanotechnologies, Academy of Science of Moldova, 2028 Chisinau, Republic of Moldova (Moldova, Republic of)

    2016-03-11

    Magnetoresistance measurements of Bi wires performed in the magnetic field oriented along the bisector axis revealed unexpected anomalous peaks in a high magnetic field far above the quantum limit of the electrons. By combining a magnetic field and an uniaxial strain, we obtained a modification of the electronic structure; as a result, the quantum limit for light and heavy electrons is changed in a different way. For the case where heavy electrons are in the quantum limit, a correlation between the exit of the lowest Landau level of light electrons and the Lifshitz transition was found. - Highlights: • Glass-coated single-crystalline Bi wires attain high limit of elastic strain of up to 3.0%. • Selective modification of the electronic structure of Bi wires is obtained by combining a high magnetic field and uniaxial strain. • The correlation between the exit of the lowest Landau level of electrons and Lifshitz transition was found.

  6. Magnetoresistance peculiarities of bismuth wires in high magnetic field

    International Nuclear Information System (INIS)

    Condrea, E.; Gilewski, A.; Nicorici, A.

    2016-01-01

    Magnetoresistance measurements of Bi wires performed in the magnetic field oriented along the bisector axis revealed unexpected anomalous peaks in a high magnetic field far above the quantum limit of the electrons. By combining a magnetic field and an uniaxial strain, we obtained a modification of the electronic structure; as a result, the quantum limit for light and heavy electrons is changed in a different way. For the case where heavy electrons are in the quantum limit, a correlation between the exit of the lowest Landau level of light electrons and the Lifshitz transition was found. - Highlights: • Glass-coated single-crystalline Bi wires attain high limit of elastic strain of up to 3.0%. • Selective modification of the electronic structure of Bi wires is obtained by combining a high magnetic field and uniaxial strain. • The correlation between the exit of the lowest Landau level of electrons and Lifshitz transition was found.

  7. Right wire in orthodontics: a review

    OpenAIRE

    Ali, Hashim

    2015-01-01

    Quality of orthodontic wire such as stiffness, hardness, resiliency, elasticity and working range are important determinants of the effectivenes of tooth movement. Commonly used types of orthodontic arch wire:1) stainless steel(ss) wire, 2) conventional nickel- titanium (NiTi)alloy wire,3) improved super elastic NiTi- alloy wire( also called low hysteresis(LH)wire), and titanium molybdenum alloy(TMA) wire.

  8. Award of two contracts for the renting of magnetic tape drives and tape libraries for LHC data storage and the purchase of the associated tape cartridges

    CERN Document Server

    2005-01-01

    This document concerns the award of two contracts for the renting and possible subsequent purchase of magnetic tape drives and tape libraries for LHC data storage. The Finance Committee is invited to agree to the procedure described in section 3 of this document for the evaluation and possible subsequent purchase of tape drives and tape libraries for the storage of data from the LHC experiments. Subject to approval of this procedure, the Finance Committee is further invited to approve the negotiation of a contract for the renting of tape drives and tape libraries for evaluation purposes from IBM, for an amount of 579 707 Swiss francs, and from StorageTek, for an amount of 472 297 Swiss francs, during the period January 2006 â?" March 2007, plus the purchase of the associated tape cartridges for amounts of 202 500 Swiss francs and 284 748 Swiss francs respectively. The Finance Committee will be informed of the results of the evaluation by the end of 2006 and, subject to the outcome, will be invited to approve...

  9. Comparative short-term in vitro analysis of mutans streptococci adhesion on esthetic, nickel-titanium, and stainless-steel arch wires.

    Science.gov (United States)

    Kim, In-Hye; Park, Hyo-Sang; Kim, Young Kyung; Kim, Kyo-Han; Kwon, Tae-Yub

    2014-07-01

    To test the hypothesis that there are no differences in mutans streptococci (MS) adhesion between esthetic and metallic orthodontic arch wires based on their surface characteristics. Surface roughness (Ra) and apparent surface free energy (SFE) were measured for six wires-four esthetic, one nickel-titanium (NiTi), and one stainless-steel (SS)-using profilometry and dynamic contact angle analysis, respectively. The amount of MS (Streptococcus mutans and Streptococcus sobrinus) adhering to the wires was quantified using the colony-counting method. The surfaces, coating layers, and MS adhesion were also observed by scanning electron microscopy. Statistical significance was set at P wires were significantly different from one another depending on the coating method (P wire showed the highest SFE, followed by the SS wire and then the four esthetic wires. The NiTi wires produced a significantly higher MS adhesion than did the SS wires (P wires showed significantly lower MS adhesions than did the NiTi wire (P < .05). Pearson correlation analyses found moderate significant positive correlations between the SFE and the S mutans and S sobrinus adhesions (r  =  .636/.427, P < .001/P  =  .001, respectively). The hypothesis is rejected. This study indicates that some esthetic coatings on NiTi alloy might reduce MS adhesion in vitro in the short term.

  10. Review of wire chamber aging

    International Nuclear Information System (INIS)

    Va'Vra, J.

    1986-02-01

    This paper makes an overview of the wire chamber aging problems as a function of various chamber design parameters. It emphasizes the chemistry point of view and many examples are drawn from the plasma chemistry field as a guidance for a possible effort in the wire chamber field. The paper emphasizes the necessity of variable tuning, the importance of purity of the wire chamber environment, as well as it provides a practical list of presently known recommendations. In addition, several models of the wire chamber aging are qualitatively discussed. The paper is based on a summary talk given at the Wire Chamber Aging Workshop held at LBL, Berkeley on January 16-17, 1986. Presented also at Wire Chamber Conference, Vienna, February 25-28, 1986. 74 refs., 18 figs., 11 tabs

  11. 3-dimensional numerical modelling of rolling of superconducting Ag/BSCCO tape

    DEFF Research Database (Denmark)

    Eriksen, Morten; Bech, Jakob Ilsted; Seifi, Behrouz

    2000-01-01

    and Ø126 mm) have been investigated. It is found that it is possible to perform numerical simulation with 3D models of flat rolling of multifilament wire. Two 3D models have been used; 3D pressing with rolls and 3D rolling. 3D pressing with rolls have the advance that the simulation time is lower than...... in the 3D rolling. The 3D models have the advantage compared to 2D pressing that they can predict the 3 dimensional flow in the flat rolling, which has been showed to be very imported for the super conduction properties......Numerical simulation of the deformation process during flat rolling of multifilament HTS tapes has been investigated using a commercial FEM program, ELFEN. The numerical models were built up in 2D and 3D using a Drucker-Prager/Cap model for the powder. Three different roll diameters (Ø24 mm, Ø85 mm...

  12. Controlled motion of domain walls in submicron amorphous wires

    Energy Technology Data Exchange (ETDEWEB)

    Ţibu, Mihai; Lostun, Mihaela; Rotărescu, Cristian; Atiţoaie, Alexandru; Lupu, Nicoleta; Óvári, Tibor-Adrian, E-mail: taovari@phys-iasi.ro; Chiriac, Horia [Department of Magnetic Materials and Devices, National Institute of Research and Development for Technical Physics, Iaşi, 700050 (Romania); Allwood, Dan A. [Department of Materials Science and Engineering, University of Sheffield, Sheffield, S1 3JD (United Kingdom)

    2016-05-15

    Results on the control of the domain wall displacement in cylindrical Fe{sub 77.5}Si{sub 7.5}B{sub 15} amorphous glass-coated submicron wires prepared by rapid quenching from the melt are reported. The control methods have relied on conical notches with various depths, up to a few tens of nm, made in the glass coating and in the metallic nucleus using a focused ion beam (FIB) system, and on the use of small nucleation coils at one of the sample ends in order to apply magnetic field pulses aimed to enhance the nucleation of reverse domains. The notch-based method is used for the first time in the case of cylindrical ultrathin wires. The results show that the most efficient technique of controlling the domain wall motion in this type of samples is the simultaneous use of notches and nucleation coils. Their effect depends on wire diameter, notch depth, its position on the wire length, and characteristics of the applied pulse.

  13. Estudo comparativo da resistência ao desgaste abrasivo do revestimento de três ligas metálicas utilizadas na indústria, aplicadas por soldagem com arames tubulares Comparative study of the wear resistance of three metal cored wire welded coatings used in industry

    Directory of Open Access Journals (Sweden)

    Ricardo Vinícius de Melo Leite

    2009-12-01

    expenditure on maintenance in industries. For the application of the coating by welding, cored wire have been a viable alternative, because of its high productivity and high weld quality, replacing in part, the use of the stick electrode. The objective of this work is to make a comparative study of the abrasive wear resistant coating deposited by welding with selfshielded cored wires of three metal alloys used in industry, first the Fe-Cr-C alloy, the second the Fe-Cr-C alloy with niobium and boron addition, and the third the Fe-Cr-C with niobium addition. The wear resistant coatings, known as hardfacing were deposited on carbon steel plates, with the same parameters and procedures of welding. The samples were obtained by cutting and grinding and were subjected to abrasive wear tests, in a Rubber Wheel apparatus, according to procedure established by ASTM G65-91. The results showed that the Fe-Cr-C alloy with Niobium and Boron addition presented superiority in terms of wear resistence.

  14. Wire communication engineering

    International Nuclear Information System (INIS)

    Son, Byeong Tae

    1997-02-01

    This book describes wire telecommunication engineering/ It is divided into eleven chapter, which deal with Introduction with development of telecommunication, voice and sound wave and communication network, Telegraphy with summary of telegraphy, code of telegraphy, communication speed, morse and telex, Telephone on structure, circuit and image telephone, Traffic on telecommunication traffic, transmission of line about theory, cable line and loaded cable, carrier communication with carrier telegraphy and carrier telephone, optical communication with types, structure, specialty, laser and equipment, DATA, Mobile telecommunication on summary, mobile telephone, radio paging and digital mobile telecommunication, ISDN with channel of ISDN, and service of ISDN, and design of telecommunication.

  15. The Micro Wire Detector

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M. E-mail: maximo.plo@cern.ch; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C

    1999-10-11

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 {mu}m{sup 2} apertures, crossed by 25 {mu}m anode strips to which it is attached by 50 {mu}m kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  16. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  17. Stabilized superconductive wires

    International Nuclear Information System (INIS)

    Randall, R.N.; Wong, J.

    1976-01-01

    A stable, high field, high current conductor is produced by packing multiple, multi-layer rods of a bronze core and niobium or vanadium inner jacket and copper outer jacket into a pure copper tube or other means for forming a pure copper matrix, sealing, working the packed tube to a wire, and by diffusion, heat treating to form a type II superconducting, Beta-Wolfram structure, intermetallic compound as a layer within each of several filaments derived from the rods. The layer of Beta-Wolfram structure compound may be formed in less than 2 h of diffusion heat treatment in a thickness of 0.5--2μ

  18. Diagnostics for exploding wires (abstract)

    International Nuclear Information System (INIS)

    Moosman, B.; Bystritskii, V.; Wessel, F.J.; Van Drie, A.

    1999-01-01

    Two diagnostics, capable of imaging fast, high temperature, plasmas were used on exploding wire experiments at UC Irvine. An atmospheric pressure nitrogen laser (λ=337.1 nm) was used to generate simultaneous shadow and shearing interferogram images with a temporal resolution of ∼1 ns and a spatial resolution of 10 μm. An x-ray backlighter imaged the exploding wire 90 degree with respect to the laser and at approximately the same instant in time. The backlighter spatial resolution as determined by geometry and film resolution was 25 μm. Copper wires of diameters (25, 50, and 100 μm) and steel wire d=25 μm were exploded in vacuum (10 -5 Torr) at a maximum current level of 12 kA, by a rectified marx bank at a voltage of 50 kV and a current rise time (quarter period) of 900 ns. Copper wires which were cleaned and then resistively heated under vacuum to incandescence for several hours prior to high current initiation, exhibited greater expansion velocities at peak current than wires which had not been heated prior to discharge. Axial variations on the surface of the wire observed with the laser were found to correlate with bulk axial mass differences from x-ray backlighting. High electron density, measured near the opaque surface of the exploding wire, suggests that much of the current is shunted outward away from the bulk of the wire. copyright 1999 American Institute of Physics

  19. Development and Characterization of P-doped Ba-122 Superconducting Tapes

    KAUST Repository

    Contarino, D.

    2016-11-29

    Among the recently discovered Fe-based superconducting compounds, the Ba-122 phase has proved to be the more attracting for the development of powder in tube (PIT) processed conductors. In fact, after some years of development, critical current densities (Jc) of about 105 A/cm2 at 4.2 K and magnetic fields up to 10 T have been obtained in (Ba0.6K0.4)Fe2As 2, PIT wires and tapes. To develop a safe upscaling method, the synthesis of the powders is a crucial point. In order to avoid the use of highly reactive K we have developed BaFe2(P1-xAsx)2 PIT tapes. This compound has proved to be very stable and in form of crystals and thin films exhibits excellent critical current: We succeeded in manufacturing PIT tapes with this phase with Jc values of about 103 A/cm2 at 4.2 K in self-field. Detailed microstructural and chemical investigations of the samples have been performed by high-resolution TEM, scanning TEM, and electron energy loss spectrometry analysis. A deformation network inside the grains that can induce strong pinning has been observed. However, chemical inhomogeneities at the grain boundaries are also present, which limit the transport current.

  20. Study of HTS Wires at High Magnetic Fields

    Energy Technology Data Exchange (ETDEWEB)

    Turrioni, D.; Barzi, E.; Lamm, M.J.; Yamada, R.; Zlobin, A.V.; Kikuchi, A.; /Fermilab

    2009-01-01

    Fermilab is working on the development of high field magnet systems for ionization cooling of muon beams. The use of high temperature superconducting (HTS) materials is being considered for these magnets using Helium refrigeration. Critical current (I{sub c}) measurements of HTS conductors were performed at FNAL and at NIMS up to 28 T under magnetic fields at zero to 90 degree with respect to the sample face. A description of the test setups and results on a BSCCO-2223 tape and second generation (2G) coated conductors are presented.

  1. Sputtered thin films for high density tape recording

    NARCIS (Netherlands)

    Nguyen, L.T.

    This thesis describes the investigation of sputtered thin film media for high density tape recording. As discussed in Chapter 1, to meet the tremendous demand of data storage, the density of recording tape has to be increased continuously. For further increasing the bit density the key factors are:

  2. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    user

    enhancement of heat transfer with twisted tape inserts as compared to plain ... studies for heat transfer and pressure drop of laminar flow in horizontal tubes ... flow in rectangular and square plain ducts and ducts with twisted-tape inserts .... presence of the insert in the pipe causes resistance to flow and increases turbulence.

  3. Recovery of recordings from heat damaged magnetic tapes

    Science.gov (United States)

    Melugin, J. F.; Obrien, D. E., III

    1973-01-01

    Damaged tapes can now be repaired at home as long as damage does not extend to layer-to-layer adhesion within tape roll. Splice repaired section into good roll or cassette for copying. Every effort should be made to complete copying on first run, because fidelity in repaired section deteriorates with each repetition.

  4. Ring shaped laser for tape winding of an endless tube

    NARCIS (Netherlands)

    Leonardus, Lucky

    2012-01-01

    AFPT is a start-up company that provides laser-assisted technology for the production of a pressurized component such as tube, pressure vessel, etc made from or strengthened by fiber reinforced plastic (FRP) tape. The tape is laid precisely by a machine head (connected to a robot), melted with a

  5. StorageTek RedWood SD-3 tape drive

    CERN Multimedia

    1995-01-01

    A helical scan recording drive, with a high-speed rotating head sweeping across the tape every few micrometers. Based on a professional video recording system, modified to be suitable for digital data recording. These are commonly used with large computer systems, typically in conjunction with a robotic tape library.

  6. Multilayer tape cast SOFC – Effect of anode sintering temperature

    DEFF Research Database (Denmark)

    Hauch, Anne; Birkl, Christoph; Brodersen, Karen

    2012-01-01

    Multilayer tape casting (MTC) is considered a promising, cost-efficient, up-scalable shaping process for production of planar anode supported solid oxide fuel cells (SOFC). Multilayer tape casting of the three layers comprising the half cell (anode support/active anode/electrolyte) can potentially...

  7. Increasing the efficiency of tape-based storage backends

    International Nuclear Information System (INIS)

    Bessone, Nicola; Cancio, German; Murray, Steve; Taurelli, Giulia

    2010-01-01

    HSM systems such as the CERN's Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for increasing the performance of repacking data from old to newer generation tape media with substantially reduced hardware costs. In this paper, we will describe the improvements for migration policies and priorities, as well as the proposed tape format and the changes which will be applied to the architecture of the CASTOR mass storage system.

  8. Scanning the melting curve of tungsten by a submicrosecond wire-explosion experiment

    International Nuclear Information System (INIS)

    Kloss, A.; Hess, H.; Schneidenbach, H.; Grossjohann, R.

    1999-01-01

    Measurements of temperature and density during a wire-explosion experiment at atmospheric pressure are described. The measurements encompass a parameter range from the solid to near the critical point. The influence of a polytetra-fluoroethylene coating of the wire, necessary to prevent surface discharges, on the temperature and density measurements is investigated. The melting curve of tungsten up to 4,000 K is determined

  9. Fabrication of long REBCO coated conductors by PLD process in China

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yijie, E-mail: yjli@sjtu.edu.cn [Key Laboratory of Artificial Structure and Quantum Control, Ministry of Education, Department of Physics and Astronomy, Shanghai Jiao Tong University, 800 Dong Chuan Road, Shanghai 20040 (China); Shanghai Superconductor Technology Corporation, Ltd, 28 Jiang Chuan Road, Shanghai 200240 (China); Liu, Linfei; Wu, Xiang [Key Laboratory of Artificial Structure and Quantum Control, Ministry of Education, Department of Physics and Astronomy, Shanghai Jiao Tong University, 800 Dong Chuan Road, Shanghai 20040 (China)

    2015-11-15

    Highlights: • SJTU fabricated 100 m long class CC tapes with over 300 A/cm on RABiTS tapes in 2011. • 100 m long CC tapes with 500 A/cm have been routinely fabricated on IBAD-MgO tapes. • The process optimization for kilometer long coated conductor tapes is underway. - Abstract: In China, the First National Key Project on CC Program started in 2009, which was focused on developing hundred meter long class CC tapes based on PLD/RABiTS processes. In this project, SJTU mainly worked on all of functional layer deposition process development. Northwest Institute for Non-ferrous Metal Research worked on RABiTS tape fabrication. At the end of the project in 2011, SJTU successfully fabricated hundred meter long CC tapes with over 300 A/cm (at 77 K, self field) on RABiTS tapes. To develop high performance CC tapes by PLD/IBAD-MgO processes, a pilot CC fabrication line was set up at Shanghai Superconductor Technology Corporation, Ltd. in 2013. High quality long REBCO coated conductors have been successfully fabricated on flexible polycrystalline metal tapes by PLD plus magnetron sputter and IBAD processes. Under optimized conditions, the IBAD-MgO layers showed pure (0 0 1) orientation and excellent in-plane texture. The in-plane phi-scan rocking curve is 4–6 degrees. AFM observation showed MgO layer had very smooth surface. The RMS is less 1 nm. On the textured MgO layer, sputter deposited single cerium oxide cap-layer showed pure (0 0 1) orientation and excellent in-plane texture of 4–6 degree. Reel-to-reel PLD process with high deposition rate was already scaled up to 100 m/h tape speed. Hundred meters long coated conductor tapes with over 500 A/cm performance have been routinely fabricated. And now, the process optimization for kilometer long coated conductor tapes is underway.

  10. Study on niobium carbide dispersed superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Wada, H; Tachikawa, K [National Research Inst. for Metals, Tokyo (Japan); Oh' asa, M [Science Univ. of Tokyo (Japan)

    1977-11-01

    Niobium carbide (NbC) dispersed superconducting tapes have been fabricated by two metallurgical processes. In the first process, Ni-Nb-C alloys are directly arc melted and hot worked in air and the NbC phase is distributed in the form of fine discrete particles. In the second process, Ni-Nb and Ni-Nb-Cu alloys are arc melted, hot worked and subjected to solid-state carburization. NbC then precipitates along the grain boundaries, forming a network. The highest superconducting transition temperature attained is about 11 K. Taken together with the lattice parameter measurement, this indicates that NbC with a nearly perfect NaCl structure is formed in both processes. Measured values of the upper critical field, the critical current density and the volume fraction of the NbC phase are also discussed.

  11. Vibration of signal wires in wire detectors under irradiation

    International Nuclear Information System (INIS)

    Bojko, I.R.; Shelkov, G.A.; Dodonov, V.I.; Ignatenko, M.A.; Nikolenko, M.Yu.

    1995-01-01

    Radiation-induced vibration of signal wires in wire detectors is found and explained. The phenomenon is based on repulsion of a signal wire with a positive potential and a cloud of positive ions that remains after neutralization of the electron part of the avalanche formed in the course of gas amplification. Vibration with a noticeable amplitude may arise from fluctuations of repulsive forces, which act on the wire and whose sources are numerous ion clusters. A formula is obtained which allows wire oscillations to be estimated for all types of wire detectors. Calculation shows that oscillations of signal wires can be substantial for the coordinate accuracy of a detector working in the limited streamer mode at fluxes over 10 5 particles per second per wire. In the proportional mode an average oscillation amplitude can be as large as 20-30 μm at some detector parameters and external radiation fluxes over 10 5 . The experimental investigations show that the proposed model well describes the main features of the phenomenon. 6 refs., 8 figs

  12. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  13. Localization of intraductal mass through the ostium of the duct using wire guided ductography technique

    International Nuclear Information System (INIS)

    Aslam, M.

    2014-01-01

    To localize intraductal mass (Papilloma) before surgery Materials Guide wire 10-15 cm length of 2/3-0 Prolene/Surgipro Plastic 26G to 20G I/V cannulas Kopans breast lesion localization hook wire Disposable syringe heaving 2ml non-ionic contrast High intensity light and magnified glass. Methods: Prepare patient in sitting or lying position adjust high intensity light clean the nipple with antiseptic lotion. Elicit the discharge with gentle periareolar pressure or ask the patient to bring the discharge. If the opening with discharge is not clearly visualize use magnified glass or loop. Slowly inserted the wire into the duct orifice, it should pass freely into the duct. Introduce the 26G I/V plastic cannula coaxially over the guide wire and remove the guide wire. Gently inject 0.2-0.4 ml contrast, remove and the syringe and apply stopper. The cannula stopper assembly is secured to the breast with tape. Magnified craniocaudal view of the breast is taken, the 26G cannula removed and bigger length 22/20G cannula gradually passed over the guide wire according to distance of lesion from the ostium. Intraductal mass location is verified the hook wire is replaced with guide wire, the position of hook confirmed by mammographic film. The wire is cut 2cms from the nipple and pt. send to operation theater Results:Hook localization has been successfully carried out in six patients. Conclusion:This is a new method of localization of intraductal mass it enables the surgeon to do microductectomy with minimal cosmetic effects to the breast. (author)

  14. Kinesio taping in patients with lateral epicondylitis.

    Science.gov (United States)

    Dilek, Banu; Batmaz, Ibrahim; Sarıyıldız, Mustafa Akif; Sahin, Ebru; Ilter, Leman; Gulbahar, Selmin; Cevik, Remzi; Nas, Kemal

    2016-11-21

    Lateral epicondylitis (LE) is a painful condition that affects the tendinous tissue of the lateral epicondyle of the humerus and leads to loss of function of the affected limb. Therefore it can have a major impact on the patient's social and personal life. Many treatments are recommended for lateral epicondylitis; unfortunately the evidence is limited. The aim of study was to investigate the effect of kinesio taping (KT) on pain, grip strength and function in patients LE. Thirty-one (23 females, 8 males) patients with LE were included. KT was applied twice a week for 2 weeks. Pain at rest, activity of daily living (ADL), night and palpation on lateral epicondyle was evaluated with the visual analog scale (VAS 0-10 cm), and the grip strength was measured with a hand held dynamometer. The stage of the disease was evaluated by the Nirschl score and the functional status was assessed with Patient-Rated Forearm Evaluation Questionnaire (PRTEQ) score. These parameters were evaluated before, at 2 weeks and 6 weeks after treatment. Patients' satisfaction was also recorded on a Likert scale after treatment at 2 weeks and 6 weeks. The average age of the patients was 43.58 ± 9.02. The dominant limb was affected in 64.5% (20) of the patients. After the application of KT on lateral epicondyle, there was a significant improvement in all parameters in terms of pain, Nirschl score, hand grip strength, patient satisfaction, and PRTEQ scores at 2 and 6 weeks. Kinesio taping can be an effective treatment method in LE. This application improves pain, grip strength and functional status of the patients with LE.

  15. Thermal anchoring of wires in large scale superconducting coil test experiment

    International Nuclear Information System (INIS)

    Patel, Dipak; Sharma, A.N.; Prasad, Upendra; Khristi, Yohan; Varmora, Pankaj; Doshi, Kalpesh; Pradhan, S.

    2013-01-01

    Highlights: • We addressed how thermal anchoring in large scale coil test is different compare to small cryogenic apparatus? • We did precise estimation of thermal anchoring length at 77 K and 4.2 K heat sink in large scale superconducting coil test experiment. • We addressed, the quality of anchoring without covering entire wires using Kapton/Teflon tape. • We obtained excellent results in temperature measurement without using GE Varnish by doubling estimated anchoring length. -- Abstract: Effective and precise thermal anchoring of wires in cryogenic experiment is mandatory to measure temperature in milikelvin accuracy and to avoid unnecessary cooling power due to additional heat conduction from room temperature (RT) to operating temperature (OT) through potential, field, displacement and stress measurement instrumentation wires. Instrumentation wires used in large scale superconducting coil test experiments are different compare to cryogenic apparatus in terms of unique construction and overall diameter/area due to errorless measurement in large time-varying magnetic field compare to small cryogenic apparatus, often shielded wires are used. Hence, along with other variables, anchoring techniques and required thermal anchoring length are entirely different in this experiment compare to cryogenic apparatus. In present paper, estimation of thermal anchoring length of five different types of instrumentation wires used in coils test campaign at Institute for Plasma Research (IPR), India has been discussed and some temperature measurement results of coils test campaign have been presented

  16. Development of high voltage lead wires using electron beam irradiation

    International Nuclear Information System (INIS)

    Bae Hunjai; Sohn Hosoung; Choi Dongjung

    1995-01-01

    It is known to those skilled to the art that the electric wires used in high voltage operating electric equipments such as TV sets, microwave ovens, duplicators and etc., have such a structure that a conductor is coated with an insulating layer which is encapsulated with a protecting jacket layer. The electric wire specification such as UL and CSA requires superior cut-through property and flame-retardant property of the wire for utilization safety. The cut-through property of insulation material, for example, high density polyethylene, can be increased by crosslinking of the polymer. Also the flame-retardant property of jacket material which protects the flammable inner insulation can be raised by flame-retardant formulating of the material. In the wire and cable industry, crosslinking by electron beam processing is more effective than that by chemical processing in the viewpoint of through-put rate of the products. The jacket layer of the wire plays the role of protecting the insulation material from burning. The protecting ability of the jacket is related to its inherent flammability and formability of swollen carbonated layer when burned. Crosslinking of the material gives a good formability of swollen carbonated layer, and it protects the insulation material from direct flame. In formulating the flame-retardant jacket material, a crosslinking system must be considered with base polymers and other flame-retardant additives. (Author)

  17. Development of high voltage lead wires using electron beam irradiation

    International Nuclear Information System (INIS)

    Bae Hunjai; Sohn Hosoung; Choi Dongjung

    1995-01-01

    It is known to those skilled to the art that the electric wires used in high voltage operating electric equipment such as TV sets, microwave ovens, duplicators etc., have such a structure that a conductor is coated with an insulating layer which is encapsulated with a protecting jacket layer. The electric wire specification such as UL and CSA requires superior cut-through and flame-retardant property of the wire for utilization safety. The cut-through property of insulation material, for example, high density polyethylene, can be increased by crosslinking of the polymer. Also the flame-retardant property of jacket material which protects the flammable inner insulation can be raised by flame-retardant formulating of the material. In the wire and cable industry, crosslinking by electron beam processing is more effective than that by chemical processing in the viewpoint of through-put rate of the products. The jacket layer of the wire plays the role of protecting the insulation material from burning. The protecting ability of the jacket is related to its inherent flammability and formability of swollen carbonated layer when burned. Crosslinking of the material gives a good formability of swollen carbonated layer, and it protects the insulation material from direct flame. In formulating the flame-retardant jacket material, a crosslinking system must be considered with base polymers and other flame-retardant additives. (Author)

  18. Transport losses in single and assembled coated conductors with textured-metal substrate with reduced magnetism

    International Nuclear Information System (INIS)

    Amemiya, N.; Jiang, Z.; Li, Z.; Nakahata, M.; Kato, T.; Ueyama, M.; Kashima, N.; Nagaya, S.; Shiohara, S.

    2008-01-01

    Transport losses in a coated conductor with a textured-metal substrate with reduced magnetism were studied experimentally. The substrate is with a clad structure, and HoBCO superconductor layer is deposited on the substrate with buffer layers. The measured transport loss of a sample whose critical current is 126.0 A falls between Norris's strip value and Norris's ellipse value. The increase in the measured transport loss from Norris's strip value can be attributed to its non-uniform lateral J c distribution. The same buffered clad tape was placed under an IBAD-MOCVD coated conductor with a non-magnetic substrate, and its transport loss was measured. The comparison between the measured transport loss of this sample and that of the identical IBAD-MOCVD coated conductor without the buffered clad tape indicates that the increase in the transport loss due to this buffered clad tape is small. The transport losses of hexagonal assemblies of IBAD-MOCVD coated conductors, whose structure simulates that of superconducting power transmission cables, were also measured where the buffered clad tapes were under-lied or over-lied on the coated conductors. The increase in the transport loss of hexagonal assemblies of coated conductors due to the buffered clad tapes is at an allowable level

  19. Observation of fast expansion velocity with insulating tungsten wires on ∼80 kA facility

    Energy Technology Data Exchange (ETDEWEB)

    Li, M.; Li, Y. [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Xi' an 710049 (China); State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Zhang, J. H.; Sun, T. P.; Wang, L. P.; Sheng, L.; Qiu, M. T.; Mao, W. T. [State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi' an 710024 (China); Wu, J., E-mail: jxjawj@mail.xjtu.edu.cn; Li, X. W. [State Key Laboratory of Electrical Insulation and Power Equipment, Xi' an Jiaotong University, Xi' an 710049 (China)

    2016-07-15

    This paper presents experimental results on the effects of insulating coatings on tungsten planar wire array Z-pinches on an 80 kA, 100 ns current facility. Expansion velocity is obviously increased from ∼0.25 km/s to ∼3.5 km/s by using the insulating coatings. It can be inferred that the wire cores are in gaseous state with this fast expansion velocity. An optical framing camera and laser probing images show that the standard wire arrays have typical ablation process which is similar to their behaviors on mega-ampere facilities. The ablation process and precursor plasma are suppressed for dielectric tungsten wires. The wire array implosion might be improved if these phenomena can be reproduced on Mega-ampere facilities.

  20. Measurement of thermal conductivity of the oxide coating on autoclaved monel-400

    International Nuclear Information System (INIS)

    Dua, A.K.; George, V.C.; Agarwala, R.P.

    1982-01-01

    Thermal conductivity of the oxide coating on monel-400 has been measured by a direct method. The oxide coating is applied on an electrically conducting wire having stable characteristics. The wire is placed in a constant temperature bath and a constant direct current is passed through it. The wire gets heated and loses heat to the surrounding. Temperature is measured by considering it as a resistance thermometer. A convection heat transfer coefficient, which is difficult to measure experimentally but is involved in the analytical expression for thermal conductivity, is eliminated by connecting a second uncoated wire of a noble metal having similar surface finish as that of the coated wire in series with it. The accuracy of the method is nearly six percent. However, the method is not easily applicable for very thin (thickness <= 1μ), highly porous coatings and materials having relatively large thermal conductivity. (M.G.B.)

  1. HTS Nested magnet wound with 12 mm GdBCO tape and 4.4 mm YBCO tape

    International Nuclear Information System (INIS)

    Kang, Myung Hun; Ku, Myung Hwan; Cha, Guee Soo; Lim, Hyoung Woo

    2015-01-01

    The properties of High Temperature Superconducting (HTS) tapes are progressing, as HTS tapes evolve from 1st generation to 2nd generation. This paper presents design and construction of a 2nd generation HTS magnet consisting of two nested GdBCO and YBCO pancake coils. Two HTS tapes of different widths were used to wind the HTS nested magnet. Considering that a higher magnetic field is applied to the inner magnet than to the outer magnet, 12 mm GdBCO tape was used for winding the inner magnet, which consisted of four single pancake windings. Eight double pancake windings wound with 4.4 mm YBCO tapes were used for the outer magnet. The test results show that the central magnetic field of the HTS nested magnet was 920 mT. The measured critical currents of the inner and outer magnet at 77K were 80.8 A and 32.6 A, respectively

  2. Diagnostics of sources of disturbances and distribution of vibrations over the width of a tape in tape-feed mechanisms

    Science.gov (United States)

    Kenstavichyus, A. B. B.

    1973-01-01

    Disturbances created by certain assemblies and components of tape-feed mechanisms (TFM) and acting on a moving magnetic tape are studied. The method, based on elements of digital logic, is established by stress-strain diagrams of the longitudinal deformations and vibrations across the width of a magnetic tape. Experimental studies were carried out for determination of the functional relationships of longitudinal deformations in a section of magnetic tape to the magnitude of roller play, tension vibrations rate of movement, and elasticity of magnetic tapes. A block diagram of the measurements is shown. Appropriate digital computer algorithms and programs were proposed for statistical analysis of the data obtained. Estimates of the mathematical expectation, dispersion, intercorrelation function, energy spectral density, and distribution pattern of the random process values were calculated.

  3. Welding wire pressure sensor assembly

    Science.gov (United States)

    Morris, Timothy B. (Inventor); Milly, Peter F., Sr. (Inventor); White, J. Kevin (Inventor)

    1994-01-01

    The present invention relates to a device which is used to monitor the position of a filler wire relative to a base material being welded as the filler wire is added to a welding pool. The device is applicable to automated welding systems wherein nonconsumable electrode arc welding processes are utilized in conjunction with a filler wire which is added to a weld pool created by the electrode arc. The invention senses pressure deviations from a predetermined pressure between the filler wire and the base material, and provides electrical signals responsive to the deviations for actuating control mechanisms in an automatic welding apparatus so as to minimize the pressure deviation and to prevent disengagement of the contact between the filler wire and the base material.

  4. Control wiring diagrams

    International Nuclear Information System (INIS)

    McCauley, T.M.; Eskinazi, M.; Henson, L.L.

    1989-01-01

    This paper discusses the changes in electrical document requirements that occur when construction is complete and a generating station starts commercial operation. The needs of operations and maintenance (O and M) personnel are analyzed and contrasted with those of construction to illustrate areas in which the construction documents (drawings, diagrams, and databases) are difficult to use for work at an operating station. The paper discusses the O and M electrical documents that the Arizona Nuclear Power Project (ANPP) believes are most beneficial for the three operating units at Palo Verde; these are control wiring diagrams and an associated document cross-reference list. The benefits offered by these new, station O and M-oriented documents are weighted against the cost of their creation and their impact on drawing maintenance

  5. Electroplated superconducting wire

    International Nuclear Information System (INIS)

    Peger, C.H.

    1991-01-01

    A hard chromium solution has been considered the least efficient of all plating solutions. This is not exactly true if the correct plating conditions are used. The accepted efficiency is only 12% but that is only true for the parameters that were used long ago to make the determination. At 12% efficiency it would be impossible to plate Superconductor wire. The world's chromium plating shops have been plating at a .001 (.025u) per hour rate since the turn of the century. Shops in the Cleveland, Ohio area have been limiting their plating rate to .006 (152u) since 1935. A few have used .012 (304u) to .030 (762u) per hour for specialized jobs. These figures would indicate the apparent efficiency of the old 100 to 1 chromium, sulfate solution can be higher than 60%. The industry uses a 3 bus bar tank with wide spacing between anode and cathode. This results in high solution resistance and high heat generation and consequently slow plating rates. The Reversible Rack 2 Bus Bar System uses very close anode to cathode spacings. This results in the high plating rates with improved quality deposits. When first asked to chromium plate pure nickel wire reel to reel in long lengths, companies making reel to reel machines were asked if chromium plating was practical. In every case, the answer was it couldn't be done. Gold, tin and zinc plating was being done reel to reel. Using the same parameters that were used to determine a chromium solution efficiency was only 12%, these other metal solutions check out close to 100%

  6. Simulation and analysis of tape spring for deployed space structures

    Science.gov (United States)

    Chang, Wei; Cao, DongJing; Lian, MinLong

    2018-03-01

    The tape spring belongs to the configuration of ringent cylinder shell, and the mechanical properties of the structure are significantly affected by the change of geometrical parameters. There are few studies on the influence of geometrical parameters on the mechanical properties of the tape spring. The bending process of the single tape spring was simulated based on simulation software. The variations of critical moment, unfolding moment, and maximum strain energy in the bending process were investigated, and the effects of different radius angles of section and thickness and length on driving capability of the simple tape spring was studied by using these parameters. Results show that the driving capability and resisting disturbance capacity grow with the increase of radius angle of section in the bending process of the single tape spring. On the other hand, these capabilities decrease with increasing length of the single tape spring. In the end, the driving capability and resisting disturbance capacity grow with the increase of thickness in the bending process of the single tape spring. The research has a certain reference value for improving the kinematic accuracy and reliability of deployable structures.

  7. Systematic Review of the Effect of Taping Techniques on Patellofemoral Pain Syndrome.

    Science.gov (United States)

    Logan, Catherine A; Bhashyam, Abhiram R; Tisosky, Ashley J; Haber, Daniel B; Jorgensen, Anna; Roy, Adam; Provencher, Matthew T

    Taping is commonly used in the management of several musculoskeletal conditions, including patellofemoral pain syndrome (PFPS). Specific guidelines for taping are unknown. To investigate the efficacy of knee taping in the management of PFPS. Our hypothesis was that tension taping and exercise would be superior to placebo taping and exercise as well as to exercise or taping alone. The PubMed/MEDLINE, Cochrane, Rehabilitation and Sports Medicine Source, and CINAHL databases were reviewed for English-language randomized controlled trials (RCTs) evaluating the efficacy of various taping techniques that were published between 1995 and April 2015. Keywords utilized included taping, McConnell, kinesio-taping, kinesiotaping, patellofemoral pain, and knee. Studies included consisted of RCTs (level 1 or 2) with participants of all ages who had anterior knee or patellofemoral pain symptoms and had received nonsurgical management using any taping technique. Systematic review. Level 2. A checklist method was used to determine selection, performance, detection, and attrition bias for each article. A quality of evidence grading was then referenced using the validated PEDro database for RCTs. Three difference comparison groups were compared: tension taping and exercise versus placebo taping and exercise (group 1), placebo taping and exercise versus exercise alone (group 2), and tension taping and exercise versus taping alone (group 3). Five RCTs with 235 total patients with multiple intervention arms were included. Taping strategies included McConnell and Kinesiotaping. Visual analog scale (VAS) scores indicated improvement in all 3 comparison groups (group 1: 91 patients, 39% of total, mean VAS improvement 44.9 [tension taping + exercise] vs 66 [placebo taping + exercise]; group 2: 56 patients, 24% of total, mean VAS improvement 66 [placebo taping + exercise] vs 47.6 [exercise alone]; and group 3: 112 patients, 48% of total, mean VAS improvement 44.9 [tension taping + exercise

  8. A study on the development of high-Tc superconducting wire

    International Nuclear Information System (INIS)

    Won, Dong Yeon; Lee, Hee Gyoun; Kim, Chan Joong

    1991-09-01

    High magnetization YBaCuO superconductor was prepared with additions of BaSnO 3 , SnO 2 and SiC by partial melt processing. Addition of BaSnO 3 increased the magnetic property of YBaCuO by flux pinning action of finely dispersed BaSnO 3 particles, while addition of SnO 2 decreased the magnetic property, because the size of particle was larger than that of BaSnO 3 . BiPbSrCaCuO superconducting tape of single filament was prepared by powder-in-tube method using silver as a shearth material. The fabrication techniques involves powder packing, swaging, drawing and cold rolling/pressing method. The final dimension of wire after drawing is 1.2mm diameter. The wire was pressed into a tape form with a thickness of 70micron and a width of 3mm. The obtained critical current density of the prepared tape was 2000A/cm 2 at 77K. (Author)

  9. Preparing superconducting nanopowder based YBCO/Ag tapes

    DEFF Research Database (Denmark)

    Paturi, P.; Raittila, J.; Grivel, J.C.

    2002-01-01

    YBCO nanopowder consisting of 1-3 nm thick and 40 nm wide particles has been used to make silver clad superconducting tapes. After annealing in nitrogen at 945 degreesC for 10 h a critical current of 5.02 A (3300 A/cm(2)) was attained, Annealing in mixed atmosphere of oxygen and nitrogen was also...... carried out and this procedure produced tapes with a critical current of 2.83 A (2200 A/cm(2)). These tapes show very good characteristics in magnetic fields. (C) 2002 Elsevier Science B.V. All rights reserved....

  10. An automated magnetic tape vault at CERN computer center

    CERN Multimedia

    Claudia Marcelloni

    2008-01-01

    The rapidly changing data processing landscape the underlying long-term storage technology remains the tried and tested magnetic tape. This robust and mature technology is used to store the complete LHC data set, from which a fraction of the data is copied to overlying disk caches for fast and widespread access. The handling of the magnetic tape cartridges is now fully automated, as they are racked in vaults where they are moved between the storage shelves and the tape drives by robotic arms.

  11. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  12. Investigation of material removal rate and surface roughness during wire electrical discharge machining (WEDM of Inconel 625 super alloy by cryogenic treated tool electrode

    Directory of Open Access Journals (Sweden)

    Ashish Goyal

    2017-10-01

    Full Text Available The present investigation focuses the effect of process parameters on material removal rate (MRR and surface roughness (Ra in wire electric discharge machining of Inconel 625. Machining was done by using a normal zinc coated wire and cryogenic treated zinc coated wire. The experiments were performed by considering different process parameters viz. tool electrode, current intensity, pulse on time, pulse off time, wire feed and wire tension. The thickness of work material and dia. of wire are kept constant. Taguchi L18 (21 * 35 orthogonal array of experimental design is used to perform the experiments. Analysis of variance (ANOVA is employed to optimize the material removal rate and surface roughness. Based on analysis it is found that pulse on time, tool electrode and current intensity are the significant parameters that affect the material removal rate and surface roughness. The scanning electron microscopy (SEM are used to identify the microstructure of the machined work piece.

  13. Development of high-temperature superconducting coated conductor by MOCVD method

    International Nuclear Information System (INIS)

    Kim, Chan Joong; Jun, Byung Hyuk; Jung, Choung Hwan

    2004-07-01

    To fabricate the second generation superconductor wire, coated conductor, we selected MOCVD (Metal organic chemical vapor deposition) method which is commercially available and whose growth rate is very high. The first buffer layer CeO 2 was successfully deposited on the Ni tape. The thick Y-stabilized ZrO 2 layer was thus inserted between two CeO 2 layers by MOCVD method. The c-axis growth of the first CeO 2 , the inserted YSZ and top CeO 2 layer was achieved by optimized the deposition condition for the three buffers. It was found that the YBCO deposition was fairly dependant on the depostion temperature, time, oxygen partial pressure, amount of the source supplied. Especially the thickness of the YBCO films was linearly dedendant on the deposition temperature and time, but current properties was not linearly dependant on the film thickness. The critical current (Ic) of the YBCO film grown on SrTiO 3 and IBAD template were over 100 A/cm-width and 50 A/cm-width at 77 K and 0 field. To establish the MOCVD process, collaboration work with several organizations was made

  14. Shuttle-Data-Tape XML Translator

    Science.gov (United States)

    Barry, Matthew R.; Osborne, Richard N.

    2005-01-01

    JSDTImport is a computer program for translating native Shuttle Data Tape (SDT) files from American Standard Code for Information Interchange (ASCII) format into databases in other formats. JSDTImport solves the problem of organizing the SDT content, affording flexibility to enable users to choose how to store the information in a database to better support client and server applications. JSDTImport can be dynamically configured by use of a simple Extensible Markup Language (XML) file. JSDTImport uses this XML file to define how each record and field will be parsed, its layout and definition, and how the resulting database will be structured. JSDTImport also includes a client application programming interface (API) layer that provides abstraction for the data-querying process. The API enables a user to specify the search criteria to apply in gathering all the data relevant to a query. The API can be used to organize the SDT content and translate into a native XML database. The XML format is structured into efficient sections, enabling excellent query performance by use of the XPath query language. Optionally, the content can be translated into a Structured Query Language (SQL) database for fast, reliable SQL queries on standard database server computers.

  15. Differences in the Microbial Colonization Among Arch Wire Types, Gauges and Cross Sections

    Directory of Open Access Journals (Sweden)

    Reem A. Rafeeq

    2018-02-01

    Full Text Available Background: The presence of orthodontic materials in the oral cavity represent a unique surface that can interact with bacteria, leading to pathogenic plaque formation and subsequent enamel demineralization, Streptococcus mutans play an important role in the initiation and progression of dental caries and they are considered the primary cause of bacteriological caries. The objective of this study was to investigate the effect of multiple factors including the type of arch wire, salivary coating, cross section, and wire thickness on the levels of mutans streptococci adherence. Materials and Methods: Two types of arch wire stainless steel and nickel titanium were selected using the following criteria: round and rectangular with gauges 0.014, 0.018, 0.016 × 0.022 and 0.019 × 0.0 25 inches which were subdivided into eight groups. Bacterial adhesion was quantified by a microbial culture technique and the number of adhesive bacteria were analyzed and counted after growth in culture for each group with and without saliva coating at 15 and 60 minutes. Detection of mutans streptococci by saliva-check Mutans test. Results: There was a significant difference between arch wire types in each time interval and the highest bacterial adhesion on the NiTi arch wires with rectangular cross section in the absence of saliva with extended incubation time. Conclusions: The adherence of mutans streptococci in saliva coated wires seems to be low. At increased incubation time, rectangular cross section arch wire showed an increased number of adhering bacteria with less effect on different gauges of the arch wire.

  16. Overcurrent experiments on HTS tape and cable conductor

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Jensen, Kim Høj; Træholt, Chresten

    2001-01-01

    their critical current. In this light, it is important to investigate the response of HTS tapes and cable conductors to overcurrents several times the critical current. A number of experiments have been performed on HTS tapes and cable conductors, with currents up to 20 times the critical current. During...... overcurrent experiments, the voltage, and the temperature were measured as functions of time in order to investigate the dynamic behavior of the HTS tape and cable conductor. After each experiment, damage to the superconductors was assessed by measuring the critical current. Preliminary results show...... that within seconds an HTS tape (critical current=17 A) heats above room temperature with an overcurrent larger than 140 A. Similar overcurrent experiments showed that a HTS cable conductor could sustain damage with overcurrents exceeding 10 times the critical current of the cable conductor....

  17. Enhancement of heat transfer using varying width twisted tape inserts

    African Journals Online (AJOL)

    International Journal of Engineering, Science and Technology ... experimental investigations of the augmentation of turbulent flow heat transfer in a horizontal tube by means of varying width twisted tape inserts with air as the working fluid.

  18. Sun StorageTek T9940 Tape Drive

    CERN Multimedia

    2002-01-01

    Technology allowed reuse of the same data cartridge at higher capacity with later model of the tape drive hence offering significant savings of the media cost. It has been use by the CERN from 2002 to 2008.

  19. ICI optical data storage tape: An archival mass storage media

    Science.gov (United States)

    Ruddick, Andrew J.

    1993-01-01

    At the 1991 Conference on Mass Storage Systems and Technologies, ICI Imagedata presented a paper which introduced ICI Optical Data Storage Tape. This paper placed specific emphasis on the media characteristics and initial data was presented which illustrated the archival stability of the media. More exhaustive analysis that was carried out on the chemical stability of the media is covered. Equally important, it also addresses archive management issues associated with, for example, the benefits of reduced rewind requirements to accommodate tape relaxation effects that result from careful tribology control in ICI Optical Tape media. ICI Optical Tape media was designed to meet the most demanding requirements of archival mass storage. It is envisaged that the volumetric data capacity, long term stability and low maintenance characteristics demonstrated will have major benefits in increasing reliability and reducing the costs associated with archival storage of large data volumes.

  20. Taping reduces pain and disability in patients with knee osteoarthritis.

    NARCIS (Netherlands)

    Ende, E. van den

    2004-01-01

    Question: Is taping of the knee effective in improving pain and disability in patients with osteoarthritis of the knee? Design Randomised controlled trial. Setting University and private practices in Melbourne, Australia. Patients: Volunteers who responded to advertisements in local newspapers.

  1. Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

    Energy Technology Data Exchange (ETDEWEB)

    Grin, A. [Building Science Corporation, Somerville, MA (United States); Lstiburek, J. [Building Science Corporation, Somerville, MA (United States)

    2014-09-01

    The goal of this research is to provide durable and long-term water management solutions using exterior insulating sheathing as part of the water management system. It is possible to tape or seal the joints in insulating sheathing to create a drainage plane and even an air control layer. There exists the material durability component of the tape as well as the system durability component being the taped insulating sheathing as the drainage plane. This measure guideline provides best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant issues were discussed with the group, which are required to make taped insulating sheathing a simple, long-term, and durable drainage plane: horizontal joints should be limited or eliminated wherever possible; where a horizontal joint exists use superior materials; and frequent installation inspection and regular trade training are required to maintain proper installation.

  2. DICOM implementation on online tape library storage system

    Science.gov (United States)

    Komo, Darmadi; Dai, Hailei L.; Elghammer, David; Levine, Betty A.; Mun, Seong K.

    1998-07-01

    The main purpose of this project is to implement a Digital Image and Communications (DICOM) compliant online tape library system over the Internet. Once finished, the system will be used to store medical exams generated from U.S. ARMY Mobile ARMY Surgical Hospital (MASH) in Tuzla, Bosnia. A modified UC Davis implementation of DICOM storage class is used for this project. DICOM storage class user and provider are implemented as the system's interface to the Internet. The DICOM software provides flexible configuration options such as types of modalities and trusted remote DICOM hosts. Metadata is extracted from each exam and indexed in a relational database for query and retrieve purposes. The medical images are stored inside the Wolfcreek-9360 tape library system from StorageTek Corporation. The tape library system has nearline access to more than 1000 tapes. Each tape has a capacity of 800 megabytes making the total nearline tape access of around 1 terabyte. The tape library uses the Application Storage Manager (ASM) which provides cost-effective file management, storage, archival, and retrieval services. ASM automatically and transparently copies files from expensive magnetic disk to less expensive nearline tape library, and restores the files back when they are needed. The ASM also provides a crash recovery tool, which enable an entire file system restore in a short time. A graphical user interface (GUI) function is used to view the contents of the storage systems. This GUI also allows user to retrieve the stored exams and send the exams to anywhere on the Internet using DICOM protocols. With the integration of different components of the system, we have implemented a high capacity online tape library storage system that is flexible and easy to use. Using tape as an alternative storage media as opposed to the magnetic disk has the great potential of cost savings in terms of dollars per megabyte of storage. As this system matures, the Hospital Information Systems

  3. The low-temperature, high-magnetic-field critical current characteristics of Zr-added (Gd, Y)Ba2Cu3Ox superconducting tapes

    Energy Technology Data Exchange (ETDEWEB)

    Selvamanickam, V; Yao, Y; Chen, Y; Shi, T; Liu, Y; Khatri, ND; Liu, J; Lei, C; Galstyan, E; Majkic, G

    2012-10-26

    Critical current performances of state-of-the-art Zr-added (Gd, Y)BaCuO tapes have been investigated over a temperature range of 20-77 K, in magnetic fields up to 9 T and over a wide angular range of magnetic field orientations. The peak in critical current that is commonly observed in the field orientation perpendicular to the tape in BaZrO3 (BZO) containing superconducting tapes is found to vanish at 30 K in magnetic fields at 1-9 T. While the critical current of 15% Zr-added tapes was about 40% lower than that of 7.5% Zr-added tapes at 77 K, the pinning force values of the former were found to be 18-23% higher than those of the latter in the temperature range of 20-40 K and in magnetic fields of 3-5 T. The results from this study emphasize the importance of optimization of coated conductor fabrication processes for optimum performance not just in low magnetic fields at 77 K but also at the operating conditions of low temperatures and high magnetic fields that are of interest, especially for rotating superconducting machinery applications.

  4. The low-temperature, high-magnetic-field critical current characteristics of Zr-added (Gd,Y)Ba2Cu3Ox superconducting tapes

    International Nuclear Information System (INIS)

    Selvamanickam, V; Yao, Y; Shi, T; Liu, Y; Khatri, N D; Liu, J; Galstyan, E; Majkic, G; Chen, Y; Lei, C

    2012-01-01

    Critical current performances of state-of-the-art Zr-added (Gd, Y)BaCuO tapes have been investigated over a temperature range of 20–77 K, in magnetic fields up to 9 T and over a wide angular range of magnetic field orientations. The peak in critical current that is commonly observed in the field orientation perpendicular to the tape in BaZrO 3 (BZO) containing superconducting tapes is found to vanish at 30 K in magnetic fields at 1–9 T. While the critical current of 15% Zr-added tapes was about 40% lower than that of 7.5% Zr-added tapes at 77 K, the pinning force values of the former were found to be 18–23% higher than those of the latter in the temperature range of 20–40 K and in magnetic fields of 3–5 T. The results from this study emphasize the importance of optimization of coated conductor fabrication processes for optimum performance not just in low magnetic fields at 77 K but also at the operating conditions of low temperatures and high magnetic fields that are of interest, especially for rotating superconducting machinery applications. (paper)

  5. Modeling birds on wires.

    Science.gov (United States)

    Aydoğdu, A; Frasca, P; D'Apice, C; Manzo, R; Thornton, J M; Gachomo, B; Wilson, T; Cheung, B; Tariq, U; Saidel, W; Piccoli, B

    2017-02-21

    In this paper we introduce a mathematical model to study the group dynamics of birds resting on wires. The model is agent-based and postulates attraction-repulsion forces between the interacting birds: the interactions are "topological", in the sense that they involve a given number of neighbors irrespective of their distance. The model is first mathematically analyzed and then simulated to study its main properties: we observe that the model predicts birds to be more widely spaced near the borders of each group. We compare the results from the model with experimental data, derived from the analysis of pictures of pigeons and starlings taken in New Jersey: two different image elaboration protocols allow us to establish a good agreement with the model and to quantify its main parameters. We also discuss the potential handedness of the birds, by analyzing the group organization features and the group dynamics at the arrival of new birds. Finally, we propose a more refined mathematical model that describes landing and departing birds by suitable stochastic processes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Tape measure to aid prescription in paediatric resuscitation.

    OpenAIRE

    Hughes, G; Spoudeas, H; Kovar, I Z; Millington, H T

    1990-01-01

    A tape measure, based on 50th centile weight for height and designed to permit easy drug dosage calculation, endotracheal tube size and DC cardioversion current dosages in childrens' emergencies, was tested for reliability by medical and nursing staff with varying paediatric experience. We found that the tape measure gave a reproducible estimate of weight and suggest that its use would facilitate decision making by inexperienced medical and nursing staff in paediatric resuscitation when there...

  7. AC power losses in Bi-2223/Ag HTS tapes

    International Nuclear Information System (INIS)

    Savvides, N.; Reilly, D.; Mueller, K.-H.; Herrmann, J.

    1998-01-01

    Full text: We report measurements at 77 K of the transport ac losses of Bi-2223/Ag composite tapes. The investigated tapes vary from single filament to multifilament construction and include both conventional tapes and other conductor shapes with twisted filaments. The self-field ac losses were determined at 77 K and 60 Hz as a function of ac current amplitude (0 - 100 A). We observe different behaviour among tapes depending on their quality and strain history. For 'good' virgin tapes the experimental data are well described by the Norris equations for the dependence of power loss P on the amplitude I m of the transport current. The data of good monofilament tapes are fitted to the Norris equation P ∼ I m n for an elliptical cross section (ie. n = 3) and the data of good multifilament tapes are fitted to the Norris equation for a rectangular strip (ie. n = 4). Many specimens, however, show a range of behaviour with lower values of n. Based on our work on the effect of strain on the dc transport properties of tapes, we carried out detailed investigations of the effect of controlled applied bend strain on the ac loss. Our results show that irreversible damage to superconducting filaments (ie. cracks) cause the ac loss to rise and n to decrease with increasing strain. In addition, applied strains much greater than the irreversible strain limit cause the ac loss to increase by several orders of magnitude and become ohmic in character with n = 2. Theoretical work is in progress to model the observed behaviour

  8. Device for stretching tapes or cables intended for manipulators

    International Nuclear Information System (INIS)

    Baudoin, J.-C.; Oger, Robert.

    1975-01-01

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device [fr

  9. Device for stretching tapes or cables intended for manipulators

    Energy Technology Data Exchange (ETDEWEB)

    Baudoin, J C; Oger, R

    1975-03-06

    The invention relates to a device for stretching tapes (or cables) intended for remote handling devices. Said equipment consists of a spring system continuously applying a constant tensile stress to said tapes (or cables) in view of taking up the slack in the latter. Said spring system is fastened to a supporting bar able to be rigidly connected to a member of the remote handling device.

  10. Outcome of transvaginal mesh and tape removed for pain only.

    Science.gov (United States)

    Hou, Jack C; Alhalabi, Feras; Lemack, Gary E; Zimmern, Philippe E

    2014-09-01

    Because there is reluctance to operate for pain, we evaluated midterm outcomes of vaginal mesh and synthetic suburethral tape removed for pain as the only indication. After receiving institutional review board approval we reviewed a prospective database of women without a neurogenic condition who underwent surgery for vaginal mesh or suburethral tape removal with a focus on pain as the single reason for removal and a minimum 6-month followup. The primary outcome was pain level assessed by a visual analog scale (range 0 to 10) at baseline and at each subsequent visit with the score at the last visit used for analysis. Parameters evaluated included demographics, mean time to presentation and type of mesh or tape inserted. From 2005 to 2013, 123 patients underwent surgical removal of mesh (69) and suburethral tape (54) with pain as the only indication. Mean followup was 35 months (range 6 to 59) in the tape group and 22 months (range 6 to 47) in the mesh group. The visual analog scale score decreased from a mean preoperative level of 7.9 to 0.9 postoperatively (p = 0.0014) in the mesh group and from 5.3 to 1.5 (p = 0.00074) in the tape group. Pain-free status, considered a score of 0, was achieved in 81% of tape and 67% of mesh cases, respectively. No statistically significant difference was found between the groups. When pain is the only indication for suburethral tape or vaginal mesh removal, a significant decrease in the pain score can be durably expected after removal in most patients at midterm followup. Copyright © 2014 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  11. Inhomogeneous wire explosion in water

    International Nuclear Information System (INIS)

    Hwangbo, C.K.; Kong, H.J.; Lee, S.S.

    1980-01-01

    Inhomogeneous processes are observed in underwater copper wire explosion induced by a condensed capacitor discharge. The wire used is 0.1 mm in diameter and 10 mm long, and the capacitor of 2 μF is charged to 5 KV. A N 2 laser is used for the diagnostic of spatial extension of exploding copper vapour. The photographs obtained in this experiment show unambiguously the inhomogeneous explosion along the exploding wire. The quenching of plasma by the surrounding water inhibits the expansion of the vapour. It is believed the observed inhomogeneous explosion along the wire is located and localized around Goronkin's striae, which was first reported by Goronkin and discussed by Froengel as a pre-breakdown phenomenon. (author)

  12. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  13. Composite conductor containing superconductive wires

    Energy Technology Data Exchange (ETDEWEB)

    Larson, W.L.; Wong, J.

    1974-03-26

    A superconductor cable substitute made by coworking multiple rods of superconductive niobium--titanium or niobium--zirconium alloy with a common copper matrix to extend the copper and rods to form a final elongated product which has superconductive wires distributed in a reduced cross-section copper conductor with a complete metallurgical bond between the normal-conductive copper and the superconductor wires contained therein is described. The superconductor cable can be in the form of a tube.

  14. Forensic Pollen Evidence from Clothes by the Tape Adhesive Method

    Directory of Open Access Journals (Sweden)

    Chun-Liang Wu

    2006-06-01

    Full Text Available Collection and identification of pollen is becoming important in forensic applications. Many criminal cases have been reported to link suspects to the crime scene by analysis of pollen. Several methods have been used in the pollen collection and analysis, but they are expensive and tedious. Therefore, it is important to develop a simple method to collect pollen grains from clothes. We tried to recover pollen from clothing surface by using the sticky tapes method. The tape adhesive method has been widely used for sample collection for various purposes, but the efficiency of recovery of invisible pollen from clothes has rarely been reported. Therefore, to test the efficiency of the tape adhesive method in recovering pollen from clothes is important. The first author wore clothes that were made from textile S made by the mixture of cotton 60% and polyester fiber 40% to collect pollen from 26 different areas mostly in the northern part of Taiwan and then used cellophane tape D (Sirchie Finger Print Lab., Inc-No. 131LT4 to recover them from different body parts. Twenty-six pollen taxa were detected in different parts of clothes depending upon what kind of plant the first author stayed near. From the results, we concluded that the tape adhesive method is suitable in recovering pollen from clothes. We have suggested that the tape adhesive method could be part of methods for collecting pollen from clothes of suspects. It is simpler, faster and less expensive than other methods.

  15. Increasing the efficiency of tape-based storage backends

    CERN Document Server

    Bessone, N; Murray, S; Taurelli, G; CERN. Geneva. IT Department

    2010-01-01

    HSM systems such as the CERN’s Advanced STORage manager (CASTOR) [1] are responsible for storing Petabytes of data which is first cached on disk and then persistently stored on tape media. The contents of these tapes are regularly repacked from older, lower-density media to new-generation, higher-density media in order to free up physical space and ensure long term data integrity and availability. With the evolution of price decay and higher capacity of disk (and flash memory) based storage, our future vision for tape usage is to move away from serving on demand, random, per-file access to non-disk cached files, and to move towards loosely coupled, efficient bulk data transfers where large-volume data sets are stored and retrieved in aggregations, fully exploiting the stream-based nature of tape media. Mechanisms for grouped migration policies and priorities have been implemented, and an innovative tape format optimized for data aggregations is being developed. This new tape format will also allow for incre...

  16. On the weld strength of in situ tape placed reinforcements on weave reinforced structures

    NARCIS (Netherlands)

    Grouve, Wouter Johannes Bernardus; Warnet, Laurent; Rietman, Bert; Akkerman, Remko

    2012-01-01

    Unidirectionally reinforced thermoplastic tapes were welded onto woven fabric reinforced laminates using a laser assisted tape placement process. A mandrel peel setup was used to quantify the interfacial fracture toughness between the tape and the laminate as a measure for weld strength. The tape

  17. A new method of measurement of tension on a moving magnetic tape

    Science.gov (United States)

    Kurtinaytis, A. K.; Lauzhinskas, Y. S.

    1973-01-01

    The possibility of no-contact measurement of the tension on a moving magnetic tape, assuming the tape is uniform, is discussed. A scheme for calculation of the natural frequency of transverse vibrations of magnetic tape is shown. Mathematical models are developed to show the relationships of the parameters. The method is applicable to the analysis of accurate tape feed mechanisms design.

  18. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  19. Wire Scanner Motion Control Card

    CERN Document Server

    Forde, S E

    2006-01-01

    Scientists require a certain beam quality produced by the accelerator rings at CERN. The discovery potential of LHC is given by the reachable luminosity at its interaction points. The luminosity is maximized by minimizing the beam size. Therefore an accurate beam size measurement is required for optimizing the luminosity. The wire scanner performs very accurate profile measurements, but as it can not be used at full intensity in the LHC ring, it is used for calibrating other profile monitors. As the current wire scanner system, which is used in the present CERN accelerators, has not been made for the required specification of the LHC, a new design of a wire scanner motion control card is part of the LHC wire scanner project. The main functions of this card are to control the wire scanner motion and to acquire the position of the wire. In case of further upgrades at a later stage, it is required to allow an easy update of the firmware, hence the programmable features of FPGAs will be used for this purpose. The...

  20. Analytical methods to characterize heterogeneous raw material for thermal spray process: cored wire Inconel 625

    Science.gov (United States)

    Lindner, T.; Bonebeau, S.; Drehmann, R.; Grund, T.; Pawlowski, L.; Lampke, T.

    2016-03-01

    In wire arc spraying, the raw material needs to exhibit sufficient formability and ductility in order to be processed. By using an electrically conductive, metallic sheath, it is also possible to handle non-conductive and/or brittle materials such as ceramics. In comparison to massive wire, a cored wire has a heterogeneous material distribution. Due to this fact and the complex thermodynamic processes during wire arc spraying, it is very difficult to predict the resulting chemical composition in the coating with sufficient accuracy. An Inconel 625 cored wire was used to investigate this issue. In a comparative study, the analytical results of the raw material were compared to arc sprayed coatings and droplets, which were remelted in an arc furnace under argon atmosphere. Energy-dispersive X-ray spectroscopy (EDX) and X-ray fluorescence (XRF) analysis were used to determine the chemical composition. The phase determination was performed by X-ray diffraction (XRD). The results were related to the manufacturer specifications and evaluated in respect to differences in the chemical composition. The comparison between the feedstock powder, the remelted droplets and the thermally sprayed coatings allows to evaluate the influence of the processing methods on the resulting chemical and phase composition.

  1. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  2. Flow structure and heat transfer in a square duct fitted with dual/quadruple twisted-tapes: Influence of tape configuration

    International Nuclear Information System (INIS)

    Eiamsa-ard, S.; Changcharoen, W.

    2015-01-01

    Numerical predictions reported of thermohydraulic characteristics of square ducts equipped with dual and quadruple twisted tapes (DTs and QTs) with different configurations. The studied cases include (1) dual co-tapes (Co-DTs), (2) dual counter-tapes (C-DTs), (3) diagonal dual counter-tapes (C-DDTs), (4) diagonal dual co-tapes (Co-DDTs), (5) quadruple co-tapes (Co-QTs), (6) quadruple counter tapes (CC-QTs) and (7) quadruple counter-tapes (PC-QTs). The results of these cases are compared with those of a smooth duct (a duct without tape insert) and also the one with a single tape (ST). The prediction involves using the RNG k-ε turbulent model under constant wall heat flux condition in the turbulent flow regime for the Reynolds number ranging from 6000 to 14000. The prediction indicates that thermohydraulic characteristics in ducts with twisted tape are strongly dependent on number and configuration of tapes. However, the influence of tape number is more significant than that of tape configuration. Heat transfer and friction increase as tape number increases. QTs offer superior heat transfer to DTs but their thermal performance factors are lower. For the tape inserts determined, DTs with diagonal configuration (Co-DDTs and C-DDTs) is the best design as the tapes offer the best thermal performance. The highest thermal performance factors given by Co-DTs, Co-DDTs, C-DTs, C-DDTs, Co-QTs, PC-QTs and CC-QTs, are around 1.21, 1.35, 1.25, 1.38, 1.08, 1.18, and 1.22, respectively

  3. Quench detection method for 2G HTS wire

    International Nuclear Information System (INIS)

    Marchevsky, M; Xie, Y-Y; Selvamanickam, V

    2010-01-01

    2G HTS conductors are increasingly used in various commercial applications and their thermal and electrical stability is an important reliability factor. Detection and prevention of quenches in 2G wire-based cables and solenoids has proven to be a difficult engineering task. This is largely due to a very slow normal zone propagation in coated conductors that leads to formation of localized hotspots while the rest of the conductor remains in the superconducting state. We propose an original method of quench and hotspot detection for 2G wires and coils that is based upon local magnetic sensing and takes advantage of 2G wire planar geometry. We demonstrate our technique experimentally and show that its sensitivity is superior to the known voltage detection scheme. A unique feature of the method is its capability to remotely detect instant degradation of the wire critical current even before a normal zone is developed within the conductor. Various modifications of the method applicable to practical device configurations are discussed.

  4. Quench detection method for 2G HTS wire

    Energy Technology Data Exchange (ETDEWEB)

    Marchevsky, M; Xie, Y-Y; Selvamanickam, V, E-mail: maxmarche@gmail.co, E-mail: yxie@superpower-inc.co [SuperPower, Inc., 450 Duane Avenue, Schenectady, NY 12304 (United States)

    2010-03-15

    2G HTS conductors are increasingly used in various commercial applications and their thermal and electrical stability is an important reliability factor. Detection and prevention of quenches in 2G wire-based cables and solenoids has proven to be a difficult engineering task. This is largely due to a very slow normal zone propagation in coated conductors that leads to formation of localized hotspots while the rest of the conductor remains in the superconducting state. We propose an original method of quench and hotspot detection for 2G wires and coils that is based upon local magnetic sensing and takes advantage of 2G wire planar geometry. We demonstrate our technique experimentally and show that its sensitivity is superior to the known voltage detection scheme. A unique feature of the method is its capability to remotely detect instant degradation of the wire critical current even before a normal zone is developed within the conductor. Various modifications of the method applicable to practical device configurations are discussed.

  5. Ignition and spread of electrical wire fires

    OpenAIRE

    Huang, Xinyan

    2012-01-01

    Ignition of electrical wires by external heating is investigated in order to gain a better understanding of the initiation of electrical-wire fires. An ignition-to- spread model is developed to systematically explain ignition and the following transition to spread. The model predicts that for a higher-conductance wire it is more difficult to achieve ignition and the weak flame may extinguish during the transition phase because of a large conductive heat loss along the wire core. Wires with tw...

  6. Obituary: Gerald Frederick Tape, 1915-2005

    Science.gov (United States)

    Hughes, Robert E.

    2007-12-01

    Gerald Frederick Tape, a distinguished science statesman and administrator, died on November 20, 2005. Jerry, as he was known to all, took on many diverse and important responsibilities throughout his life and dealt with them with quiet authority and grace. This was the hallmark of his life. The Board of Trustees of Associated Universities, Inc., which he served for many years, expressed this in its condolences, writing "Jerry personified integrity, thoroughness and dedication. His sensitivity for the views of others, his sincerity, his personal commitment, his calm approach and his unfailing good humor were all greatly admired and respected." Jerry was born in Ann Arbor, Michigan on May 29, 1915 but grew up in Milan, a nearby country farm community, and in Ypsilanti where his father was Principal of Michigan State Normal College, which later became Eastern Michigan University (EMU). It was there that he first became interested in physics. It was there also that he met and courted Josephine Waffen, who later would become his wife for more than sixty-six years and fill their lives with three loving sons, Walter, James, and Thomas. Upon graduation from EMU, Jerry was awarded a scholarship that took him to the University of Michigan where he earned a Ph.D. in Physics, researching the decay modes of the radioisotopes of iodine. In the Fall of 1939, during the waning days of the Great Depression, he was offered an Instructorship in the Physics Department of Cornell University, a promising start for a fruitful academic career. He brought his bride Jo to Ithaca and joined the cyclotron group under Robert Bacher and Willy Higginbotham while devising a laboratory course in nuclear techniques for graduate students. Bacher and Higginbotham soon left Cornell to join a new wartime laboratory at the Massachusetts Institute of Technology (MIT) and many other colleagues were "drafted" for war work. Bacher persuaded Jerry to join him at the MIT Radiation Laboratory in February

  7. Homogenous BSCCO-2212 Round Wires for Very High Field Magnets

    International Nuclear Information System (INIS)

    Campbell, Scott; Holesinger, Terry; Huang, Ybing

    2012-01-01

    index (n-value) sufficiently high to meet the field decay requirements (in persistent magnets), piece lengths long enough to wind coils, and acceptably low costs. HEP has traditionally used very high current magnets made from Rutherford cables, and the ability to be cabled is another key advantage. Very high on the list of materials able to fulfill the requirements above is Bi-2212 round wire. Both cables and high field coils on a small scale have been demonstrated using this material. By contrast, YBCO is a single-filament tape that is not easy to cable. As shown in Figure 1 these tapes are highly anisotropic in their current density. In the good orientation the performance is considerably better than Bi-2212, however at the highest fields measured, the isotropic current behavior of 2212 exceeds the bad orientation of YBCO.

  8. Radiographic Outcomes of Postoperative Taping Following Hallux Valgus Correction.

    Science.gov (United States)

    Ponzio, Danielle Y; Pedowitz, David I; Verma, Kushagra; Maltenfort, Mitchell G; Winters, Brian S; Raikin, Steven M

    2015-07-01

    Traditionally, hallux valgus operative correction has been accompanied by serial spica taping of the great toe during the postoperative period. We retrospectively reviewed 187 adult patients who underwent proximal first metatarsal osteotomy with a modified McBride procedure in 2008-2009 (n = 83) and 2011-2012 (n = 104). Postoperatively, to maintain the corrected position of the hallux, patients from 2008 through 2009 underwent weekly spica taping, while patients from 2011 through 2012 utilized a toe separator. The hallux valgus angle (HVA) and intermetatarsal angle (IMA) were measured using anteroposterior weight-bearing preoperative, 2-week postoperative non-weight-bearing, and 3-month weight-bearing final follow-up radiographs. A mixed-effects linear regression model identified differences between the treatment groups over time, and a t test compared actual radiographic differences at final follow-up. The mixed-effects model revealed no significant difference in the HVA over time when comparing patients taped to those not taped at the preoperative (33 ± 6 vs 33 ± 6), 2-week postoperative (10 ± 7 vs 9 ± 6), and 3-month follow-up (14 ± 6 vs 11 ± 7) visits (P = .08). At final follow-up, the HVA was lower for the group that was not taped, but the difference (2.5 degrees) was below the minimal clinically important difference (MCID) (P = .015, 95% CI 0.5-4.5). For IMA, there was improved maintenance of correction over time in the patients that were not taped compared to those taped at the preoperative (15 ± 3 vs 15 ± 3), 2-week postoperative (2 ± 2 vs 3 ± 3), and 3-month follow-up (5 ± 4 vs 7 ± 4) visits (P = .002). At final follow-up, the IMA was lower for the group that was not taped, but the difference (1.7 degrees) was below the MCID (P = .004, 95% CI 0.7-2.9). We report no radiographic benefit of postoperative taping after hallux valgus correction. The present study challenges the previous dogma of postoperative spica taping as the protocol is cost and

  9. Red Tape dan Perilaku Masyarakat dalam Pelayanan Izin Usaha Perdagangan di Kota Makassar

    OpenAIRE

    Lukman, Lukman

    2015-01-01

    : Red tape as pathology has long been the focus of an expert study of bureaucracy. Early scholarly attempts conceptualized red tape at the individual level as in Merton's classic thesis (1940) about goal displacement. Waldo (1946) one man's red tape is another man's system. Kaufman (1977) one person's red tape may be another's treasured safeguard. Osborne and Gaebler (1992) good people trapped in bad systems. Bozeman and Feneey (2011) red tape is often used as a synonym of the term procedures...

  10. High transport current superconductivity in powder-in-tube Ba0.6K0.4Fe2As2 tapes at 27 T

    Science.gov (United States)

    Huang, He; Yao, Chao; Dong, Chiheng; Zhang, Xianping; Wang, Dongliang; Cheng, Zhe; Li, Jianqi; Awaji, Satoshi; Wen, Haihu; Ma, Yanwei

    2018-01-01

    The high upper critical field and low anisotropy of iron-based superconductors (IBS) make them particularly attractive for high-field applications, especially for the construction of next-generation nuclear magnetic resonance spectrometers, particle accelerators and high-field magnets. However, for practical use it is essential to make IBS materials into wire and tape conductors with sufficient current carrying capability, which is limited by misaligned grains inside the conductors. Here, based on a simple and low-cost powder-in-tube (PIT) method, we demonstrate a high transport critical current density (J c) reaching 1.5 × 105 A cm-2 (I c = 437 A) at 4.2 K and 10 T in Ba0.6K0.4Fe2As2 (Ba-122) tapes by texturing the grain orientation with optimized hot-press technique. The transport J c measured at 4.2 K under high magnetic fields of 27 T is still on the level of 5.5 × 104 A cm-2. Moreover, at 20 K and 5 T the transport J c is also as high as 5.4 × 104 A cm-2, showing a promising application potential in moderate temperature range which can be reached by liquid hydrogen or cryogenic cooling. All these J c values are the highest ever reported for IBS wires and tapes. The high-performance PIT Ba-122 tapes in this work suggest IBS to be a strong potential competitor of cuprate superconductors for the race of high-field applications in the future.

  11. Mechanical properties of high-temperature superconducting wires. Ph.D. Thesis - Illinois Inst. of Tech.

    Science.gov (United States)

    Goretta, K. C.; Cluff, J. A.; Joo, J.; Lanagan, M. T.; Singh, J. P.; Vasanthamohan, N.; Xin, Y.; Wong, K. W.

    1995-01-01

    Bending strength, fracture toughness, and elastic modulus data were acquired for YBa2Cu3O(x), Bi2Sr2CaCu2O(x) (Bi,Pb)2Sr2Ca2Cu3O(x), and Tl2Ba2Ca2Cu3O(x) bars. These data and thermal expansion coefficients strongly suggest that the maximum possible tensile strain without fracture of bulk tapes or wires is approximately equals 0.2%. In Ag-clad conductors, residual stresses will be of limited benefit, but fractures produced by larger strains can be accommodated by shunting current through the Ag.

  12. Phase transitions in coated nickel titanium arch wires: A differential ...

    Indian Academy of Sciences (India)

    Division of Orthodontics, Indian Army, 10 Corps Dental Unit, C/O 56 APO, ... Shape memory and super-elastic properties of orthodontic nickel titanium ... test did not show any significant difference in mean values of transition ... Low enthalpy values (0·92–3·59 j/g) compared to conventional ones, implied complete phase.

  13. Effects of ultrasound therapy with taping PNF training and PNF training with taping in treatment and rehabilitation of sports injuries of high ankle sprain

    Directory of Open Access Journals (Sweden)

    D L Charly Daniel

    2017-01-01

    Conclusions: It was concluded that combining ultrasound with taping and PNF training with taping were found to be more beneficial in the treatment and rehabilitation of high ankle sprain injury. The combined effect of UT, PNF training, and taping may be explored by future researchers.

  14. Comparison of Tension-free Vaginal Tape Versus Transobturator Tape in Women with Stress Urinary Incontinence

    Directory of Open Access Journals (Sweden)

    Zinat Ghanbari

    2007-06-01

    Full Text Available Objective: This study compared the Tension-free vaginal tape (TVT and Transobturator tape (TOT procedures for surgical treatment of stress urinary incontinence in women.Materials and methods: This prospective non randomized clinical trial was conducted in Vali-e-asr hospital from March 2001 to March 2005. A total of 71 patients with clinical and urodynamic diagnosis of Stress urinary incontinence (SUI were enrolled in the study. Patients were divided into two groups and underwent TVT or TOT procedures. Mean operation time, cure rate, post operative urinary retention, bleeding and infection were compared between two groups. SPSS software was used for statistical analysis. Chi square and fisher exact test calculated the effects of the nominal variables. Mean difference of quantitative variables were compared by student's T- test. P ≤0.05 was considered statistically significant. Results: There was no significant difference in mean time of operation and peri-operative complications among groups. Urinary retention was 13.8% (n=5 in the TVT group versus 2.8% (n=1 in TOT group (NS. The rates of cure (91.6% vs 91.4%, improvement (5.6% vs 8.6% and failure (2.8% vs 0 were similar for the TVT and TOT groups. The rate of hemorrhagic complications was 5.5% in TVT and 2.8% in TOT group (NS.Conclusion: TOT appears to be equally efficient to TVT for surgical treatment of stress urinary incontinence after 30 months follow-up.

  15. Technical innovation: Wire guided ductography

    International Nuclear Information System (INIS)

    Aslam, Muhammad Ovais; Ramadan, Salwa; Al-Adwani, Muneera

    2012-01-01

    To introduce an easy and improved technique for performing ductography using inexpensive easily available intravenous cannula. Guide wire: Prolene/Surgipro 3-0 (Polypropylene mono filament non-absorbable surgical suture). A plastic 26 G intravenous cannula. Disposable syringe 2 ml. Non-ionic contrast (low density like Omnipaque 240 mg I/I). The guide wire (Prolene 3-0) is introduced into the orifice of the duct heaving discharge and 26 G intravenous plastic cannula is then passed over the guide wire. The cannula is advanced in the duct over guide wire by spinning around it. When the cannula is in place the guide wire is removed. Any air bubbles present in the hub of the cannula can be displaced by filling the hub from bottom upwards with needle attached to contrast filled syringe. 0.2–0.4 ml non-ionic contrast is gently injected. Injection is stopped if the patient has pain or burning. Magnified cranio-caudal view is obtained with cannula tapped in place and gentle compression is applied with the patient sitting. If duct filling is satisfactory a 90* lateral view is obtained. A successful adaptation of the technique for performing ductography is presented. The materials required for the technique are easily available in most radiology departments and are inexpensive, thus making the procedure comfortable for the patient and radiologist with considerable cost effectiveness.

  16. Californium Recovery from Palladium Wire

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Jon D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-08-01

    The recovery of 252Cf from palladium-252Cf cermet wires was investigated to determine the feasibility of implementing it into the cermet wire production operation at Oak Ridge National Laboratory’s Radiochemical Engineering Development Center. The dissolution of Pd wire in 8 M HNO3 and trace amounts of HCl was studied at both ambient and elevated temperatures. These studies showed that it took days to dissolve the wire at ambient temperature and only 2 hours at 60°C. Adjusting the ratio of the volume of solvent to the mass of the wire segment showed little change in the kinetics of dissolution, which ranged from 0.176 mL/mg down to 0.019 mL/mg. A successful chromatographic separation of 153Gd, a surrogate for 252Cf, from Pd was demonstrated using AG 50x8 cation exchange resin with a bed volume of 0.5 mL and an internal diameter of 0.8 cm.

  17. Ectopic bone formation in nude rats using human osteoblasts seeded poly(3)hydroxybutyrate embroidery and hydroxyapatite-collagen tapes constructs.

    Science.gov (United States)

    Mai, Ronald; Hagedorn, Manolo Gunnar; Gelinsky, Michael; Werner, Carsten; Turhani, Dritan; Späth, Heike; Gedrange, Tomas; Lauer, Günter

    2006-09-01

    The aim of this study was to evaluate the ectopic bone formation using tissue engineered cell-seeded constructs with two different scaffolds and primary human maxillary osteoblasts in nude rats over an implantation period of up to 96 days. Collagen I-coated Poly(3)hydroxybutyrate (PHB) embroidery and hydroxyapatite (HAP) collagen tapes were seeded with primary human maxillary osteoblasts (hOB) and implanted into athymic rnu/run rats. A total of 72 implants were placed into the back muscles of 18 rats. 24, 48 and 96 days after implantation, histological and histomorphometric analyses were made. The osteoblastic character of the cells was confirmed by immunocytochemistry and RT-PCR for osteocalcin. Histological analysis demonstrated that all cell-seeded constructs induced ectopic bone formation after 24, 48 and 96 days of implantation. There was more mineralized tissue in PHB constructs than in HAP-collagen tapes (at day 24; p embroidery or HAP-collagen tapes can induce ectopic bone formation. However, the amount of bone formed decreased with increasing length of implantation.

  18. A visualization instrument to investigate the mechanical-electro properties of high temperature superconducting tapes under multi-fields

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Wei; Zhang, Xingyi, E-mail: zhangxingyi@lzu.edu.cn; Liu, Cong; Zhang, Wentao; Zhou, Jun; Zhou, YouHe [Key Laboratory of Mechanics on Disaster and Environment in Western China Attached to the Ministry of Education of China, Lanzhou University, Lanzhou, Gansu 730000, People’s Republic of China and Department of Mechanics and Engineering Sciences, College of Civil Engineering and Mechanics, Lanzhou University, Lanzhou, Gansu 730000 (China)

    2016-07-15

    We construct a visible instrument to study the mechanical-electro behaviors of high temperature superconducting tape as a function of magnetic field, strain, and temperature. This apparatus is directly cooled by a commercial Gifford-McMahon cryocooler. The minimum temperature of sample can be 8.75 K. A proportion integration differentiation temperature control is used, which is capable of producing continuous variation of specimen temperature from 8.75 K to 300 K with an optional temperature sweep rate. We use an external loading device to stretch the superconducting tape quasi-statically with the maximum tension strain of 20%. A superconducting magnet manufactured by the NbTi strand is applied to provide magnetic field up to 5 T with a homogeneous range of 110 mm. The maximum fluctuation of the magnetic field is less than 1%. We design a kind of superconducting lead composed of YBa2Cu3O7-x coated conductor and beryllium copper alloy (BeCu) to transfer DC to the superconducting sample with the maximum value of 600 A. Most notably, this apparatus allows in situ observation of the electromagnetic property of superconducting tape using the classical magnetic-optical imaging.

  19. Carbon-coated anatase for water purification - cyclic performance

    International Nuclear Information System (INIS)

    Inagaki, M.; Kojin, F.; Nonaka, M.; Toyoda, M.

    2005-01-01

    It was reported that carbon-coated anatase photo-catalysts were able to be prepared through a simple process and gave various advantages for water purification [1-6]. Carbon coating suppressed the phase transformation from anatase to rutile, resulting in a high crystallinity of anatase phase which was desirable for the decomposition of pollutants in water. A high adsorptivity was given to carbon-coated anatase, because of porous nature of carton layers [7]. In addition, these carbon-coated anatase powders could be fixed on the substrate by using organic binder because carbon layer interrupt the direct contact between photo-catalytic anatase particles and organic binder [1]. In the present work, cyclic performance of carbon-coated anatase was studied for the decomposition of a model pollutant, methylene blue (MB), in water by fixing the photo-catalyst particles on a tape. Carbon-coated anatase photo-catalysts were prepared by heating the powder mixtures of commercially available anatase (ST-01, Ishihara Sngyo Co., Ltd) with poly(vinyl alcohol) (PVA) in different mass ratios at 900 C in N 2 , gas flow. Carbon-coated anatase powders thus prepared were fixed on a scotch tape. Photo-catalytic activity was measured on these tapes by irradiating UV rays on one side of the tape in MB solution with 0.3x10 -5 mol/L concentration. Since carbon-coated anatase had a high adsorptivity for MB, all tapes were saturated their adsorption in a concentrated MB solution in advance. The rate constant k for MB photo-decomposition was determined from the linear relations of logarithm of relative concentration of MB in the solution, ln(c/c 0 ), with irradiation time t. In Fig. 1, changes in ln(c/c 0 ) of MB with irradiation time t were shown on two samples with different carbon contents, 8 and 2 mass%, with cycle number. Good linearity was obtained between ln(c/c 0 ) and t. The values of rate constant k calculated from these linear relations were plotted against carbon content of the

  20. Three-dimensional modelling of metal evaporated tape

    International Nuclear Information System (INIS)

    Kay, G.E.

    1999-06-01

    As developments in magnetic recording increase, the demands for high density recording media continue to rise. One particular medium developed towards meeting these needs is the commercially successful metal evaporated (ME) tape. To provide a deeper understanding of the magnetic processes occurring in recording media, theoretical studies are carried out to complement experimental observations. Therefore, this thesis is concerned with developing a micromagnetic model to simulate the magnetic behaviour of ME tape. ME tape consists of bundles of granular columns which are tilted towards the film normal. The morphology of the film influences the magnetic behaviour and a 3D model is developed in this thesis to represent the columnar structure and the granular nature of ME tape. A Monte Carlo algorithm, consisting of a 'move and grow' procedure, is developed to generate an irregular system of spherical grains whose radii were generated from a log-normal distribution. This structure provides the foundation for modelling columns of ME tape. Initially an isolated column of ME tape was investigated. Grains were considered to be single domain and the dynamic process of the magnetic moments was explored by the Landau-Lifschitz equation. The model demonstrated that as the strength of the exchange coupling parameter increased, then moments which were strongly coupled resisted large negative fields and square hysteresis loops with a high coercivity were produced. Reversal of the moments was observed to be initiated at the ends of a column and then propagated throughout the column. This was attributed to large demagnetising fields and was particularly evident in the model with aligned easy axes. If the easy axes were randomly orientated then more disorder was present in the model and moments rotated incoherently. This produced hysteresis loops that were less square than those of the aligned model. The results also showed how the microstructure influenced the reversal processes

  1. Molybdenum plasma spray powder, process for producing said powder, and coating made therefrom

    International Nuclear Information System (INIS)

    Lafferty, W.D.; Cheney, R.F.; Pierce, R.H.

    1979-01-01

    Plasma spray powders of molybdenum particles containing 0.5 to 15 weight percent oxygen and obtained by reacting molybdenum particles with oxygen or oxides in a plasma, form plasma spray coatings exhibiting hardness comparable to flame sprayed coatings formed from molybdenum wire and plasma coatings of molybdenum powders. Such oxygen rich molybdenum powders may be used to form wear resistant coatings, such as for piston rings. (author)

  2. Dynamic response of HTS composite tapes to pulsed currents

    International Nuclear Information System (INIS)

    Meerovich, V; Sokolovsky, V; Prigozhin, L; Rozman, D

    2006-01-01

    Dynamic voltage-current characteristics of an HTS Ag/BiSCCO composite tape are studied both experimentally and theoretically. The tape is subjected to pulsed currents with different shapes and magnitudes and voltage traces are measured using the four-point method with different locations of potential taps on the sample surface. Clockwise and anticlockwise hysteresis loops are obtained for the same sample depending on the location of the potential taps. The dynamic characteristics deviate substantially from the DC characteristic, especially in the range of low voltages where a criterion for the critical current value is usually chosen (1-10 μV cm -1 ). The critical current determined from dynamic characteristics and its change with the pulse magnitude depend on the location of the potential taps and on the curve branch chosen for the critical current determination (ascending or descending). The theoretical analysis is based on a model of the magnetic flux diffusion into a composite tape for a superconductor described by the flux creep characteristic. Numerical simulation based on this model gives results in good agreement with the experimental ones and explains the observed peculiarities of the dynamic characteristics of HTS composite tapes. The difference between the magnetic diffusion into a tape and a slab is discussed

  3. Penetrating cardiac injury by wire thrown from a lawn mower.

    Science.gov (United States)

    Rubio, P A; Reul, G J

    1979-01-01

    The first successful surgically treated case of penetrating heart injury, specifically the right ventricle, caused by a fragment of coat hanger wire thrown by a lawn mower, is reported. Though traumatic heart injuries are rare, this case represents accurate surgical management and judgment, especially in the preoperative phase which resulted in early operating and excellent postoperative results. It is our feeling that if the patient can be transferred safely to the operating room the mortality rate is considerably lowered; however, emergency room thoracotomy, which will undoubtedly result in a greater survival rate from these spectacular injuries, should be performed in the emergency center if cardiac activity ceases or the patient's condition deteriorates considerably.

  4. Apparatus and method for pulsed laser deposition of materials on wires and pipes

    Science.gov (United States)

    Fernandez, Felix E.

    2003-01-01

    Methods and apparatuses are disclosed which allow uniform coatings to be applied by pulsed laser deposition (PLD) on inner and outer surfaces of cylindrical objects, such as rods, pipes, tubes, and wires. The use of PLD makes this technique particularly suitable for complex multicomponent materials, such as superconducting ceramics. Rigid objects of any length, i.e., pipes up to a few meters, and with diameters from less than 1 centimeter to over 10 centimeters can be coated using this technique. Further, deposition is effected simultaneously onto an annular region of the pipe wall. This particular arrangement simplifies the apparatus, reduces film uniformity control difficulties, and can result in faster operation cycles. In addition, flexible wires of any length can be continuously coated using the disclosed invention.

  5. Bidirectional recording performance of a perpendicular evaporated Co-CoO tape

    Energy Technology Data Exchange (ETDEWEB)

    Motohashi, K. [Sony Corporation, 3-4-1 Sakuragi, Tagajo-shi, Miyagi 985-0842 (Japan)], E-mail: Kazunari.Motohashi@jp.sony.com; Ikeda, N.; Sato, T.; Shiga, D.; Ono, H.; Onodera, S. [Sony Corporation, 3-4-1 Sakuragi, Tagajo-shi, Miyagi 985-0842 (Japan)

    2008-11-15

    It is the first report on the recording performance of a perpendicular metal evaporated (ME) tape measured with a giant magnetoresistive head. To solve the application difficulty of oblique evaporated tape media to linear scan tape systems, a perpendicular evaporated Co-CoO tape was proposed instead. The prepared sample showed perpendicular anisotropy with coercivity of 107.3 kA/m, M{sub r}t of 3.9 mA and squareness of 0.25. Identical recording characteristics were obtained for both head-media moving directions, which enables the application of perpendicular evaporated Co-CoO tape to linear scan tape systems. The better carrier-to-noise ratio was also confirmed by comparison with a current advanced product of metal particulate tape, which can realize the higher recording density of linear scan tape systems using ME tape.

  6. Bidirectional recording performance of a perpendicular evaporated Co-CoO tape

    International Nuclear Information System (INIS)

    Motohashi, K.; Ikeda, N.; Sato, T.; Shiga, D.; Ono, H.; Onodera, S.

    2008-01-01

    It is the first report on the recording performance of a perpendicular metal evaporated (ME) tape measured with a giant magnetoresistive head. To solve the application difficulty of oblique evaporated tape media to linear scan tape systems, a perpendicular evaporated Co-CoO tape was proposed instead. The prepared sample showed perpendicular anisotropy with coercivity of 107.3 kA/m, M r t of 3.9 mA and squareness of 0.25. Identical recording characteristics were obtained for both head-media moving directions, which enables the application of perpendicular evaporated Co-CoO tape to linear scan tape systems. The better carrier-to-noise ratio was also confirmed by comparison with a current advanced product of metal particulate tape, which can realize the higher recording density of linear scan tape systems using ME tape

  7. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T.

    2010-10-15

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  8. Stick-slip substructure in rapid tape peeling

    KAUST Repository

    Thoroddsen, Sigurdur T; Nguyen, H. D.; Takehara, K.; Etoh, T. G.

    2010-01-01

    The peeling of adhesive tape is known to proceed with a stick-slip mechanism and produces a characteristic ripping sound. The peeling also produces light and when peeled in a vacuum, even X-rays have been observed, whose emissions are correlated with the slip events. Here we present direct imaging of the detachment zone when Scotch tape is peeled off at high speed from a solid surface, revealing a highly regular substructure, during the slip phase. The typical 4-mm-long slip region has a regular substructure of transverse 220 μm wide slip bands, which fracture sideways at speeds over 300 m/s. The fracture tip emits waves into the detached section of the tape at ∼100 m/s, which promotes the sound, so characteristic of this phenomenon.

  9. Age-of-Air, Tape Recorder, and Vertical Transport Schemes

    Science.gov (United States)

    Lin, S.-J.; Einaudi, Franco (Technical Monitor)

    2000-01-01

    A numerical-analytic investigation of the impacts of vertical transport schemes on the model simulated age-of-air and the so-called 'tape recorder' will be presented using an idealized 1-D column transport model as well as a more realistic 3-D dynamical model. By comparing to the 'exact' solutions of 'age-of-air' and the 'tape recorder' obtainable in the 1-D setting, useful insight is gained on the impacts of numerical diffusion and dispersion of numerical schemes used in global models. Advantages and disadvantages of Eulerian, semi-Lagrangian, and Lagrangian transport schemes will be discussed. Vertical resolution requirement for numerical schemes as well as observing systems for capturing the fine details of the 'tape recorder' or any upward propagating wave-like structures can potentially be derived from the 1-D analytic model.

  10. Effect of the Ignition Method on the Extinction Limit for a Flame Spreading over Electric Wire Insulation

    DEFF Research Database (Denmark)

    Mitsui, Fumiya; Nagachi, Masashi; Citerne, Jean-Marie

    . The experimental results show that the LOC of NiCr core wires assume an almost constant value under normal gravity conditions once ignition occurred, whereas under microgravity conditions, the LOC gradually decreases as the ignition power or heating time increases and eventually it reaches an almost constant value......Flame spread experiments with wire insulation were conducted in microgravity (parabolic flights) and in normal gravity to understand the effect of the ignition condition on the Limiting Oxygen Concentration (LOC) for an opposed air flow condition of 100 mm/s (typical flow velocity on ISS). Both...... the ignition power (50-110 W) and the igniter heating time (5-15 s) were varied. Polyethylene-coated Nickel-Chrome or copper wires with inner core diameter of 0.50 mm and insulation thickness of 0.30 mm were used as sample wires, and a 0.50 mm diameter coiled Kanthal wire was used as the igniter...

  11. A 5.9 tesla conduction-cooled coil composed of a stack of four single pancakes wound with YBCO wide tapes

    Energy Technology Data Exchange (ETDEWEB)

    Iwai, Sadanori, E-mail: sadanori.iwai@toshiba.co.jp; Miyazaki, Hiroshi; Tosaka, Taizo; Tasaki, Kenji; Urata, Masami; Ioka, Shigeru; Ishii, Yusuke

    2013-11-15

    Highlights: •We made a coil composed of a stack of four single pancakes wound with YBCO wide tapes. •The coil had a central magnetic field as high as 5.9 T at 20 K. •The effect of the tape width on the central magnetic field was small near coil I{sub c}. •We confirmed that performance of YBCO coil was improved by using wider tape. -- Abstract: We have been developing a conduction-cooled coil wound with YBCO-coated conductors for HTS applications. Previously, we have fabricated a coil composed of a stack of 12 single pancakes wound with 4 mm-wide YBCO tapes. This coil had a central magnetic field as high as 5.1 T at 10 K under conduction-cooled conditions. In the present study, we fabricated and tested a coil composed of a stack of four single pancakes wound with 12 mm-wide YBCO tapes. The total size of the coil and the J{sub c} value of the tapes were almost the same as those of the former coil. At 77 K, the voltage–current characteristics showed a high n-value of 24, confirming that the coil had no degradation. Furthermore, in a conduction-cooled configuration at 20 K to 60 K, the coil showed a high n-value of over 20. At 20 K, the central magnetic field reached 5.9 T at 903 A, which is 1.3-times higher than that of the former coil.

  12. Mirror-Touch and Ticker Tape Perceptions in Synesthesia

    Directory of Open Access Journals (Sweden)

    Charlotte Anne Chun

    2013-11-01

    Full Text Available A fundamental question in the field of synesthesia is whether it is associated with other cognitive phenomena. The current study examined synesthesia’s connections with phenomenal traits of mirror-touch and ticker tape experiences, as well as the representation of the three phenomena in the population, across gender and domain of work/study. Mirror-touch is the automatic, involuntary experience of tactile sensation on one's own body when others are being touched. For example, seeing another person’s arm being stroked can evoke physical touch sensation on one’s own arm. Ticker tape is the automatic visualization of spoken words or thoughts, such as a teleprompter. For example, when spoken to, a ticker taper might see mentally the spoken words displayed in front of his face or as coming out of the speaker’s mouth. To explore synesthesia’s associations with these phenomena, a diverse group (n=3,743 was systematically recruited from eight universities and one public museum in France to complete an online screening. Of the 1,017 eligible respondents, synesthetes (across all subtypes reported higher rates of mirror-touch and ticker tape than non-synesthetes, suggesting that synesthesia is associated with these phenomenal traits. However effect size was small and we could not rule out that response bias influenced these associations. Mirror-touch and ticker tape were independent. No differences were found across gender or domain of work and study in prevalence of synesthesia, mirror-touch or ticker tape. The prevalence of ticker tape, unknown so far, was estimated at about 7%, an intermediate rate between estimates of grapheme-color (2 to 4% and sequence-space synesthesia (9 to 14%. Within synesthesia, grapheme-personification, also called ordinal-linguistic personification was the most common subtype and was estimated around 12%. Co-occurences of the different types of synesthesia were higher than chance, though at the level of small effect

  13. Influence of the constant load sintering on the improvement of the transport critical current in Ag-(Bi,Pb)[sub 2]Sr[sub 2]Ca[sub 2]Cu[sub 3]O[sub x] tape form conductor

    Energy Technology Data Exchange (ETDEWEB)

    Jackiewicz, J [IRC in Superconductivity, Univ. of Cambridge (United Kingdom); Glowacki, B A [IRC in Superconductivity, Univ. of Cambridge (United Kingdom) Dept. of Materials Science and Metallurgy, Univ. of Cambridge (United Kingdom)

    1993-05-10

    The effects of the short time, low value constant load pressing process of cold rolled silver clad wires conducted at temperatures close to the partial melting point of the ceramic core, from 800 C to 866 C on the microstructure and critical current anisotropy have been studied in detail. The strong influence of the constant load sintering at up to 2 MPa for 1 hour on the improvement of the alignment of the ceramic core in the tape form conductors was confirmred by microstructure investigations and also by the I[sub c] versus [mu][sub 0]H measurements. The magnetic field dependence of the transport critical current, for [mu][sub 0]H parallel to the surface of the tape and also for [mu][sub 0]H perpendicular to the surface of the tape, is very significantly reduced in the tapes sintered under constant load. The analysis of the mechanical creep of silver and ceramic core versus temperature allowed us to optimise the densification conditions of the investigated single core Ag-''2223'' tape form conductor for the load used. (orig.)

  14. Enhancement in transport critical current density of ex situ PIT Ag/(Ba, K)Fe2As2 tapes achieved by applying a combined process of flat rolling and uniaxial pressing

    Science.gov (United States)

    Togano, Kazumasa; Gao, Zhaoshun; Matsumoto, Akiyoshi; Kumakura, Hiroaki

    2013-11-01

    We report that the transport critical current density Jc of ex situ powder-in-tube (PIT) processed (Ba, K)Fe2As2 (Ba-122) tapes can be significantly enhanced by applying uniaxial cold pressing at the final stage of deformation. The tapes were prepared by packing high quality precursor powder into a Ag tube, cycles of rolling and intermediate annealing, and pressing followed by the final heat treatment for sintering. The Jc values in applied magnetic fields were increased by almost one order of magnitude compared to the tapes processed without pressing, exceeding 104 A cm-2 at 4.2 K. We achieved the highest Jc (at 4.2 K and 10 T) of 2.1×104 A cm-2 among PIT-processed Fe-based wires and tapes reported so far. The Jc-H curves measured at higher temperatures maintain small field dependence up to around 20 K, suggesting that these tapes are promising for applications at higher temperatures as well as at liquid helium temperature. The microstructure investigations reveal that there are two possible causes of the large Jc enhancement by pressing: one is densification and the other is the change of crack structure. Optimization of processing parameters such as the reduction ratio of rolling and pressing is expected to yield further Jc enhancement.

  15. Patient goals after tension free vaginal tape operation

    DEFF Research Database (Denmark)

    Glavind, Karin; Bjørk, Jonna; Kousgaard, Sabrina Just

    INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology and Obstetr......INTRODUCTION: This prospective study investigates sexual function in women after a tension-free vaginal tape (TVT) operation and compares short-term and long-term effects. METHODS: Sixty-three women had a TVT operation performed at Aalborg University Hospital, Department of Gynecology...

  16. The new CERN tape software - getting ready for total performance

    CERN Document Server

    Cano, E; Kruse, D F; Kotlyar, V; Côme, D

    2015-01-01

    CASTOR (the CERN Advanced STORage system) is used to store the custodial copy of all of the physics data collected from the CERN experiments, both past and present. CASTOR is a hierarchical storage management system that has a disk-based front-end and a tape-based back-end. The software responsible for controlling the tape back-end has been redesigned and redeveloped over the last year and was put in production at the beginning of 2015. This paper summarises the motives behind the redesign, describes in detail the redevelopment work and concludes with the short and long-term benefits.

  17. Properties of hot pressed MgB2/Ti tapes

    International Nuclear Information System (INIS)

    Kovac, P.; Husek, I.; Melisek, T.; Fedor, J.; Cambel, V.; Morawski, A.; Kario, A.

    2009-01-01

    Hot axial and hot isostatic pressing was applied for single-core MgB 2 /Ti tapes. Differences in transport current density, n-exponents and critical current anisotropy are discussed and related to the grain connectivity influenced by pressing. The magnetic Hall probe scanning measurements allowed observing the isolated regions for axially hot pressed sample attributed to the longitudinally oriented cracks introduced by pressing. The highest current densities were measured for the tape subjected to hot isostatic pressing due to improved connectivity.

  18. A Grazing-Incidence Small-Angle X-Ray Scattering View of Vertically Aligned ZnO Nano wires

    International Nuclear Information System (INIS)

    Lavcevic, M.L.; Silovic, L.; Dubcek, P.; Pavlovic, M.; Bernstorff, S.

    2013-01-01

    We report a grazing-incidence small-angle X-ray scattering study of ZnO films with vertically aligned and randomly distributed nano wires, grown through a hydrothermal growth process on nano structured ZnO seeding coatings and deposited by electron beam evaporation on silicon and glass, respectively. The comparison of the scattering patterns of seeding coatings and nano wires showed that the scattering of vertically aligned nano wires exhibited a specific feature: the dominant characteristic of their scattering patterns is the appearance of fine structure effects around the specular peak. These effects were clarified by the combined reflection and scattering phenomena, suggested for the aligned nano wires-substrate system. Furthermore, they enabled the calculation of the average gyration radius of nano wires in horizontal direction. The calculated value was in good agreement with the radii of nano wires estimated by surface electron microscopy. Therefore, the observed feature in the scattering pattern can serve as evidence of the aligned growth of nano wires.

  19. Electromagnetic field analyses of two-layer power transmission cables consisting of coated conductors with magnetic and non-magnetic substrates and AC losses in their superconductor layers

    International Nuclear Information System (INIS)

    Nakahata, Masaaki; Amemiya, Naoyuki

    2008-01-01

    Two-dimensional electromagnetic field analyses were undertaken using two representative cross sections of two-layer cables consisting of coated conductors with magnetic and non-magnetic substrates. The following two arrangements were used for the coated conductors between the inner and outer layers: (1) tape-on-tape and (2) alternate. The calculated magnetic flux profile around each coated conductor was visualized. In the case of the non-magnetic substrate, the magnetic field to which coated conductors in the outer layer are exposed contains more perpendicular component to the conductor wide face (perpendicular field component) when compared to that in the inner layer. On the other hand, for the tape-on-tape arrangement of coated conductors with a magnetic substrate, the reverse is true. In the case of the alternate arrangement of the coated conductor with a magnetic substrate, the magnetic field to which the coated conductors in the inner and outer layers are exposed experiences a small perpendicular field component. When using a non-magnetic substrate, the AC loss in the superconductor layer of the coated conductors in the two-layer cables is dominated by that in the outer layer, whereas the reverse is true in the case of a magnetic substrate. When comparing the AC losses in superconductor layers of coated conductors with non-magnetic and magnetic substrates in two-layer cables, the latter is larger than the former, but the influence of the magnetism of substrates on AC losses in superconductor layers is not remarkable

  20. Comparison of growth texture in round Bi2212 and flat Bi2223 wires and its relation to high critical current density development

    OpenAIRE

    Kametani, F.; Jiang, J.; Matras, M.; Abraimov, D.; Hellstrom, E. E.; Larbalestier, D. C.

    2015-01-01

    Why Bi2Sr2CaCu2Ox (Bi2212) allows high critical current density Jc in round wires rather than only in the anisotropic tape form demanded by all other high temperature superconductors is important for future magnet applications. Here we compare the local texture of state-of-the-art Bi2212 and Bi2223 ((Bi,Pb)2Sr2Ca2Cu3O10), finding that round wire Bi2212 generates a dominant a-axis growth texture that also enforces a local biaxial texture (FWHM

  1. Transparency in nanophotonic quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Mahi R [Department of Physics and Astronomy, University of Western Ontario, London N6A 3K7 (Canada)

    2009-03-28

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  2. Transparency in nanophotonic quantum wires

    International Nuclear Information System (INIS)

    Singh, Mahi R

    2009-01-01

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  3. Fabrication of tungsten wire needles

    International Nuclear Information System (INIS)

    Roder, A.

    1983-02-01

    Fine point needles for field emissoin are conventionally produced by electrolytically or chemically etching tungsten wire. Points formed in this manner have a typical tip radius of about 0.5 microns and a cone angle of some 30 degrees. The construction of needle matrix detector chambers has created a need for tungsten needles whose specifications are: 20 mil tungsten wire, 1.5 inch total length, 3 mm-long taper (resulting in a cone angle of about 5 degrees), and 25 micron-radius point (similar to that found on sewing needles). In the process described here for producing such needles, tungsten wire, immersed in a NaOH solution and in the presence of an electrode, is connected first to an ac voltage and then to a dc supply, to form a taper and a point on the end of the wire immersed in the solution. The process parameters described here are for needles that will meet the above specifications. Possible variations will be discussed under each approprite heading

  4. [Mechanics analysis of fracture of orthodontic wires].

    Science.gov (United States)

    Wang, Yeping; Sun, Xiaoye; Zhang, Longqi

    2003-03-01

    Fracture problem of orthodontic wires was discussed in this paper. The calculation formulae of bending stress and tensile stress were obtained. All main factors that affect bending stress and tensile stress of orthodontic wires were analyzed and discussed. It was concluded that the main causes of fracture of orthodontic wires were fatigue and static disruption. Some improving proposals for preventing fracture of orthodontic wires were put forward.

  5. 49 CFR 236.74 - Protection of insulated wire; splice in underground wire.

    Science.gov (United States)

    2010-10-01

    ... underground wire. 236.74 Section 236.74 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING... wire; splice in underground wire. Insulated wire shall be protected from mechanical injury. The...

  6. 49 CFR 234.241 - Protection of insulated wire; splice in underground wire.

    Science.gov (United States)

    2010-10-01

    ... underground wire. 234.241 Section 234.241 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION GRADE CROSSING SIGNAL SYSTEM SAFETY... of insulated wire; splice in underground wire. Insulated wire shall be protected from mechanical...

  7. Detection of a buried wire with two resistively loaded wire antennas

    NARCIS (Netherlands)

    Vossen, S.H.J.A.; Tijhuis, A.G.; Lepelaars, E.S.A.M.; Zwamborn, A.P.M.

    2002-01-01

    The use of two identical straight thin-wire antennas for the detection of a buried wire is analyzed with the aid of numerical calculations. The buried wire is located below an interface between two homogeneous half-spaces. The detection setup, which is formed by a transmitting and a receiving wire,

  8. One century of Kirschner wires and Kirschner wire insertion techniques : A historical review

    NARCIS (Netherlands)

    Franssen, Bas B. G. M.; Schuurman, Arnold H.; Van der Molen, Aebele Mink; Kon, Moshe

    A century ago, in 1909, Martin Kirschner (1879-942) introduced a smooth pin, presently known as the Kirschner wire (K-wire). The K-wire was initiallly used for skeletal traction and is now currently used for many different goals. The development of the K-wire and its insertion devices were mainly

  9. The Effect of Fluoridated and Non Fluoridated Mouth Washes on Color Stability of Different Aesthetic Arch Wires At Different Time Intervals (An in Vitro Study

    Directory of Open Access Journals (Sweden)

    Lubna Maky Hussein

    2018-01-01

    Full Text Available Background:The color stability of aesthetic arch wires is an important factor in the success of an aesthetic orthodontic treatment, but the color of these arch wires tends to change with time.This study was performed to assess the effect of two types of mouth washes on the color  stability of different types of aesthetic arch wires at different time intervals. Materials and methods:Four brands of nickel titanium coated aesthetic arch wires were used: epoxy coated (Orthotechnology and G&H and Teflon coated (Dany and Hubit.Thirty six samples were prepared, each sample contains ten halves of the aesthetic arch wires. They were divided into three groups according to the immersion media (distilled water as a control media, Listerine with fluoride and Listerine without fluoride and immersed for 30 seconds twice daily according to manufacturer's instructions to measure color change after 1 week, 3 weeks and 6 weeks by using spectrophotometer VITA Easyshade Compact according to Commission Internationale de l’Eclairage L*a*b* color space system. Results:It was found that there were highly significant differences in color change values of aesthetic arch wires among all immersion media at different time intervals and color change value increases as the time of immersion increases.Additionally, Listerine with fluoride mouth wash caused higher color change values of aesthetic arch wires than Listerine without fluoride and Hubit aesthetic arch wires were the least color stable while Orthotechnology aesthetic arch wires were the most color stable. Conclusions: We can conclude that the daily use of Listerine mouth washes could affect on the color stability of aesthetic arch wires. Although all tested aesthetic arch wires revealed color changes at variable degrees but some of these changes were not  visible and the others were clinically acceptable while the remaining were clinically unacceptable.

  10. Pre-wired systems prove their worth.

    Science.gov (United States)

    2012-03-01

    The 'new generation' of modular wiring systems from Apex Wiring Solutions have been specified for two of the world's foremost teaching hospitals - the Royal London and St Bartholomew's Hospital, as part of a pounds sterling 1 billion redevelopment project, to cut electrical installation times, reduce on-site waste, and provide a pre-wired, factory-tested, power and lighting system. HEJ reports.

  11. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems...

  12. Getting "Wired" for McLuhan's Cyberculture.

    Science.gov (United States)

    McMurdo, George

    1995-01-01

    Examines the introduction of the computing magazine, "Wired", into the United Kingdom's (UK) market. Presents conversations with the founder and editorial staff of the UK edition, and discusses the accessibility of "Wired" via the World Wide Web. Describes 10 articles from United States "Wired" back-issues and…

  13. Kinesthetic taping improves walking function in patients with stroke

    DEFF Research Database (Denmark)

    Boeskov, Birgitte; Carver, Line Tornehøj; von Essen-Leise, Anders

    2014-01-01

    BACKGROUND: Stroke is an important cause of severe disability and impaired motor function. Treatment modalities that improve motor function in patients with stroke are needed. The objective of this study was to investigate the effect of kinesthetic taping of the anterior thigh and knee on maximal...... be a valuable adjunct in physical therapy and rehabilitation of patients with stroke....

  14. Cutting red tape: national strategies for administrative simplification

    National Research Council Canada - National Science Library

    Cerri, Fabienne; Hepburn, Glen; Barazzoni, Fiorenza

    2006-01-01

    ... when the topic was new, and had a strong focus on the tools used to simplify administrative regulations. Expectations are greater today, and ad hoc simplification initiatives have in many cases been replaced by comprehensive government programmes to reduce red tape. Some instruments, such as one-stop shops, which were new then, have become widely adop...

  15. Researchers wrangle petabytes of data storage with NAS, tape

    CERN Multimedia

    Pariseau, Beth

    2007-01-01

    "Much is made in the enterprise data storage industry about the performance of disk systems over tape drives, but the managers of one data center that has eached the far limits of capacity say otherwise. Budget and performance demands forced them to build access protocols and data management tools for disk systems from scratch."

  16. Kodak phase-change media for optical tape applications

    Science.gov (United States)

    Tyan, Yuan-Sheng; Preuss, Donald R.; Olin, George R.; Vazan, Fridrich; Pan, Kee-Chuan; Raychaudhuri, Pranab. K.

    1993-01-01

    The SbInSn phase-change write-once optical medium developed by Eastman Kodak Company is particularly suitable for development into the next generation optical tape media. Its performance for optical recording has already been demonstrated in some of the highest performance optical disk systems. Some of the key performance features are presented.

  17. Standard Practice for Sampling for Particulate Contamination by Tape Lift

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2006-01-01

    1.1 This practice covers procedures for sampling surfaces to determine the presence of particulate contamination, 5 m and larger. The practice consists of the application of a pressure-sensitive tape to the surface followed by the removal of particulate contamination with the removal of the tape. The tape with the adhering particles is then mounted on counting slides. Counting and measuring of particles is done by standard techniques. 1.2 This practice describes the materials and equipment required to perform sampling of surfaces for particle counting and sizing. 1.3 The criteria for acceptance or rejection of a part for conformance to surface cleanliness level requirements shall be determined by the user and are not included in this practice. 1.4 This practice is for use on surfaces that are not damaged by the application of adhesive tape. The use of this practice on any surface of any material not previously tested or for which the susceptibility to damage is unknown is not recommended. In general, metal...

  18. Tape casting and partial melting of Bi-2212 thick films

    Energy Technology Data Exchange (ETDEWEB)

    Buhl, D.; Lang, T.; Heeb, B. [Nichtmetallische Werkstoffe, Zuerich (Switzerland)] [and others

    1994-12-31

    To produce Bi-2212 thick films with high critical current densities tape casting and partial melting is a promising fabrication method. Bi-2212 powder and organic additives were mixed into a slurry and tape casted onto glass by the doctor blade tape casting process. The films were cut from the green tape and partially molten on Ag foils during heat treatment. We obtained almost single-phase and well-textured films over the whole thickness of 20 {mu}m. The orientation of the (a,b)-plane of the grains were parallel to the substrate with a misalignment of less than 6{degrees}. At 77K/OT a critical current density of 15`000 A/cm{sup 2} was reached in films of the dimension 1cm x 2cm x 20{mu}m (1{mu}V/cm criterion, resistively measured). At 4K/OT the highest value was 350`000 A/cm{sup 2} (1nV/cm criterion, magnetically measured).

  19. Modeling and Velocity Tracking Control for Tape Drive System ...

    African Journals Online (AJOL)

    Modeling and Velocity Tracking Control for Tape Drive System. ... Journal of Applied Sciences and Environmental Management ... The result of the study revealed that 7.07, 8 and 10 of koln values met the design goal and also resulted in optimal control performance with the following characteristics 7.31%,7.71% , 9.41% ...

  20. Fabrication of laminated Bi-2212/Ag multifilamentary tape

    Science.gov (United States)

    Yuan, D.-W.; Majer, W. J.; Francavilla, T. L.

    2000-03-01

    The powder-in-tube (PIT) process has been successfully used to make long lengths of Ag-sheathed oxide superconductors. A modified PIT approach is proposed to fabricate conductors with laminated Bi-2212 configurations. Ag/Bi-2212 tapes consisting of seven laminae were produced with various thicknesses ranging from 0.38 to 0.25 mm. The use of a turkshead was found to be beneficial, yielding tapes with good dimensional integrity and consistency. Critical current density (Jc ) values greater than 105 A cm-2 (0.01 T and Bicons/Journals/Common/perp" ALT="perp" ALIGN="TOP"/> tape surface) have been attained for tapes of different thicknesses. Nonetheless, Jc was found to be related to the average thickness of individual Bi-2212 lamina. It is believed that excessive cold working accounts for the decrease in Jc with decreasing size below a threshold value. The enhancement of Jc is attributed to the high Bi-2212 grain alignment along the Ag-oxide interfaces and uniform dimensions within the laminate conductors.