WorldWideScience

Sample records for wires syst biol

  1. Armas biológicas

    OpenAIRE

    Bruhn Cuevas, Rosa María

    2016-01-01

    Abordamos el presente trabajo con el objetivo de realizar una revisión bibliográfica que nos permita elaborar un análisis del empleo de armas biológicas tanto en el pasado, es decir, una documentación de la utilización de éstas a lo largo de la historia, quiénes las utilizaban y el porqué de su utilización, dividido en varios periodos; como en el presente, si se siguen empleando en la actualidad, con especial mención de los protocolos que existen en cuanto a su regulación normativa a día de h...

  2. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  4. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  5. Implementace ERP systémů

    OpenAIRE

    Přívratský, Miroslav

    2008-01-01

    První část této práce uvádí vztah ERP systémů a jiných aplikací běžně zaváděných v podnikových informačních systémech a rozvádí funkcionalitu ERP systémů. Druhá část se poté věnuje detailní kategorizaci ERP produktů z mnoha různých hledisek a analyzuje obecné parametry, podle kterých je možné ERP systémy posuzovat (např. při výběru produktu, který má být implementován). Poslední část je zaměřena na projekty implementace ERP systémů, jejich průběh a hodnocení jejich úspěšnosti. Na závěr práce ...

  6. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  7. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  8. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  9. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  10. Pacemaker wires

    International Nuclear Information System (INIS)

    Fransson, S.G.

    1993-01-01

    Evaluation of pacemaker wires were performed by comparing Advanced Multiple Beam Equalization Radiography (AMBER) with conventional chest radiography. The scanning equalization technique of the AMBER unit makes it superior to conventional technique in the depiction of different structures in the mediastinum or in the pleural sinuses. So far motion artifacts have not been considered clinically important. The longer exposure time, however, may impair the assessment of pacemaker wires. The motion artifact described may not only make adequate evaluation impossible but may even give a false impression of a lead fracture. The difference between the two systems was significant. (orig.)

  11. The SysteMHC Atlas project.

    Science.gov (United States)

    Shao, Wenguang; Pedrioli, Patrick G A; Wolski, Witold; Scurtescu, Cristian; Schmid, Emanuel; Vizcaíno, Juan A; Courcelles, Mathieu; Schuster, Heiko; Kowalewski, Daniel; Marino, Fabio; Arlehamn, Cecilia S L; Vaughan, Kerrie; Peters, Bjoern; Sette, Alessandro; Ottenhoff, Tom H M; Meijgaarden, Krista E; Nieuwenhuizen, Natalie; Kaufmann, Stefan H E; Schlapbach, Ralph; Castle, John C; Nesvizhskii, Alexey I; Nielsen, Morten; Deutsch, Eric W; Campbell, David S; Moritz, Robert L; Zubarev, Roman A; Ytterberg, Anders Jimmy; Purcell, Anthony W; Marcilla, Miguel; Paradela, Alberto; Wang, Qi; Costello, Catherine E; Ternette, Nicola; van Veelen, Peter A; van Els, Cécile A C M; Heck, Albert J R; de Souza, Gustavo A; Sollid, Ludvig M; Admon, Arie; Stevanovic, Stefan; Rammensee, Hans-Georg; Thibault, Pierre; Perreault, Claude; Bassani-Sternberg, Michal; Aebersold, Ruedi; Caron, Etienne

    2018-01-04

    Mass spectrometry (MS)-based immunopeptidomics investigates the repertoire of peptides presented at the cell surface by major histocompatibility complex (MHC) molecules. The broad clinical relevance of MHC-associated peptides, e.g. in precision medicine, provides a strong rationale for the large-scale generation of immunopeptidomic datasets and recent developments in MS-based peptide analysis technologies now support the generation of the required data. Importantly, the availability of diverse immunopeptidomic datasets has resulted in an increasing need to standardize, store and exchange this type of data to enable better collaborations among researchers, to advance the field more efficiently and to establish quality measures required for the meaningful comparison of datasets. Here we present the SysteMHC Atlas (https://systemhcatlas.org), a public database that aims at collecting, organizing, sharing, visualizing and exploring immunopeptidomic data generated by MS. The Atlas includes raw mass spectrometer output files collected from several laboratories around the globe, a catalog of context-specific datasets of MHC class I and class II peptides, standardized MHC allele-specific peptide spectral libraries consisting of consensus spectra calculated from repeat measurements of the same peptide sequence, and links to other proteomics and immunology databases. The SysteMHC Atlas project was created and will be further expanded using a uniform and open computational pipeline that controls the quality of peptide identifications and peptide annotations. Thus, the SysteMHC Atlas disseminates quality controlled immunopeptidomic information to the public domain and serves as a community resource toward the generation of a high-quality comprehensive map of the human immunopeptidome and the support of consistent measurement of immunopeptidomic sample cohorts. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  12. The SysteMHC Atlas project

    DEFF Research Database (Denmark)

    Shao, Wenguang; Pedrioli, Patrick G. A.; Wolski, Witold

    2018-01-01

    consisting of consensus spectra calculated from repeat measurements of the same peptide sequence, and links to other proteomics and immunology databases. The SysteMHC Atlas project was created and will be further expanded using a uniform and open computational pipeline that controls the quality of peptide......-scale generation of immunopeptidomic datasets and recent developments in MS-based peptide analysis technologies now support the generation of the required data. Importantly, the availability of diverse immunopeptidomic datasets has resulted in an increasing need to standardize, store and exchange this type of data...

  13. Tiempo y edad biológica

    Directory of Open Access Journals (Sweden)

    Vargas, Esteban

    2013-04-01

    Full Text Available In this paper we attempt to think if it is possible to conceive age as a characteristic time of living organisms including man. In the paper we review several concepts of age coming from sciences such as chronobiology, gerontology, evolutionary biology and developmental biology, and trough all of them, we see that biological time is thought as time measured by a clock. We propose that age as biological time must be understood as a phase in the biological process, but depending on the complete cycle of the organism. In the case of human being, his age is determined also by what is “expected” about him. His age is then determined by biological and cultural aspects.En este trabajo intentamos meditar si es posible concebir la edad como un tiempo propio de los seres vivos incluyendo al hombre. En el trabajo revisamos diversos conceptos de edad obtenidos de diversas ciencias biológicas como la cronobiología, la gerontología, la biología evolutiva y la biología del desarrollo descubriendo que en ellas, en general, se sigue pensando el tiempo biológico como el tiempo que mide un reloj. Nosotros proponemos que la edad como tiempo biológico debe ser entendida como una fase del proceso biológico, pero en función del ciclo completo del organismo. En el caso del ser humano, su edad está determinada también por lo que se “espera” de él. Su edad está determinada entonces por aspectos biológicos y culturales.

  14. Application of irradiated wire

    International Nuclear Information System (INIS)

    Uda, I.; Kozima, K.; Suzuki, S.; Tada, S.; Torisu, S.; Veno, K.

    1984-01-01

    Rubber insulated wires are still useful for internal wiring in motor vehicles and electrical equipment because of flexibility and toughness. Irradiated cross-linked rubber materials have been successfully introduced for use with fusible link wire and helically coiled cord

  15. Noncontextual Wirings

    Science.gov (United States)

    Amaral, Barbara; Cabello, Adán; Cunha, Marcelo Terra; Aolita, Leandro

    2018-03-01

    Contextuality is a fundamental feature of quantum theory necessary for certain models of quantum computation and communication. Serious steps have therefore been taken towards a formal framework for contextuality as an operational resource. However, the main ingredient of a resource theory—a concrete, explicit form of free operations of contextuality—was still missing. Here we provide such a component by introducing noncontextual wirings: a class of contextuality-free operations with a clear operational interpretation and a friendly parametrization. We characterize them completely for general black-box measurement devices with arbitrarily many inputs and outputs. As applications, we show that the relative entropy of contextuality is a contextuality monotone and that maximally contextual boxes that serve as contextuality bits exist for a broad class of scenarios. Our results complete a unified resource-theoretic framework for contextuality and Bell nonlocality.

  16. Systèmes de Gestion de Production et Systèmes de Contrôle de Gestion

    OpenAIRE

    Travaillé , Denis

    2009-01-01

    L'interrogation fondamentale des travaux de recherche porte sur la question de la séparabilité et de l'interaction entre système de gestion de production et système de contrôle de gestion. Le premier temps de la réflexion concerne la spécificité du contrôle de gestion en contexte de "Juste-à-Temps. Le second temps de la recherche est relatif aux systèmes d'information de production intégrés en relation avec le système de contrôle de gestion et au rôle des représentations comptables dans la qu...

  17. Wire breakage in SLC wire profile monitors

    International Nuclear Information System (INIS)

    Field, C.; McCormick, D.; Raimondi, P.; Ross, M.

    1998-05-01

    Wire scanning beam profile monitors are used at the Stanford Linear Collider (SLC) for emittance preservation control and beam optics optimization. Twenty such scanners have proven most useful for this purpose and have performed a total of 1.5 million scans in the 4 to 6 years since their installation. Most of the essential scanners are equipped with 20 to 40 microm tungsten wires. SLC bunch intensities and sizes often exceed 2 x 10 7 particles/microm 2 (3C/m 2 ). The authors believe that this has caused a number of tungsten wire failures that appear at the ends of the wire, near the wire support points, after a few hundred scans are accumulated. Carbon fibers, also widely used at SLAC, have been substituted in several scanners and have performed well. In this paper, the authors present theories for the wire failure mechanism and techniques learned in reducing the failures

  18. El progreso biológico

    Directory of Open Access Journals (Sweden)

    Barahona, Ana

    1997-12-01

    Full Text Available Not available.La idea de progreso en Biología está ligada al concepto de scala naturae o la gran cadena del ser que se puede trazar hasta Aristóteles. Esta noción de que los organismos vivientes pueden clasificarse en una jerarquía de inferior a superior tomó formas nuevas en los siglos XVII y XVIII. En el siglo XVIII, naturalistas como Buffon, Bonnet y Robinet se habían preguntado si podíamos hablar de un patrón definido de desarrollo. En el siglo XIX, Lamarck postula la idea de que existe una progresión de los organismos menos avanzados a los organismos más avanzados. Posteriormente, la teoría de la evolución añade la dimensión temporal y de continuidad genética o histórica a la clasificación jerárquica de los seres vivos. Darwin pensaba que la selección natural traía como resultado el perfeccionamiento y que éste inevitablemente conduciría al progreso gradual de la organización. Herbert Spencer se convirtió en uno de los darwinistas más radicales del siglo XIX y principios del XX. Para Spencer la idea de progreso se aplicaba no solo al mundo biológico sino que era parte de una ley general, que dirigía lo simple hacia lo complejo, lo homogéneo a lo heterogéneo. Posteriormente, Julian Huxley, Theodosius Dobzhansky, Ernst Mayr, George Gaylord Simpson y Ledyard Stebbins —conocidos como los arquitectos de la Sintesis Moderna— comparten una visión progresionista de la evolución biológica. La noción de progreso evolutivo, en la actualidad, es sumamente controvertida, y se pueden distinguir básicamente tres diferentes perspectivas. La primera, defendida por Michael Ruse y David Hull entre otros, sostiene que no existe evidencia científica que nos lleve a aceptar cierta «direccionalidad» en la evolución biológica. Una segunda visión, defendida por Stephen J. Gould, sostiene que, en la medida en que reemplacemos el término de progreso (ya que éste es antropocéntrico por el de «noción operacional de

  19. Firemní ERP systém

    OpenAIRE

    Komárek, Lukáš

    2010-01-01

    Tato bakalářská práce pojednává o problematice tvorby ERP systému na platformě .NET Framework s využitím Microsoft technologií. Jednotlivé kapitoly seznámí čtenáře s analýzou, návrhem a implementací vlastního ERP systému. Čtenář bude podrobněji seznámen se zařazením a komponentami ERP systému, moderními vývojovými technologiemi a nástroji, příkladem návrhu modulů a funkcí ERP systému včetně implementace a nasazení aplikace ERP systému. This thesis focuses on the issues while creating the E...

  20. Base Information Transport Infrastructure Wired (BITI Wired)

    Science.gov (United States)

    2016-03-01

    2016 Major Automated Information System Annual Report Base Information Transport Infrastructure Wired (BITI Wired) Defense Acquisition Management...Combat Information Transport System program was restructured into two pre-Major Automated Information System (pre-MAIS) components: Information...Major Automated Information System MAIS OE - MAIS Original Estimate MAR – MAIS Annual Report MDA - Milestone Decision Authority MDD - Materiel

  1. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  2. Water Desalination with Wires

    NARCIS (Netherlands)

    Porada, S.; Sales, B.B.; Hamelers, H.V.M.; Biesheuvel, P.M.

    2012-01-01

    We show the significant potential of water desalination using a novel capacitive wire-based technology in which anode/cathode wire pairs are constructed from coating a thin porous carbon electrode layer on top of electrically conducting rods (or wires). By alternately dipping an array of electrode

  3. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  4. Effect of wire shape on wire array discharge

    Energy Technology Data Exchange (ETDEWEB)

    Shimomura, N.; Tanaka, Y.; Yushita, Y.; Nagata, M. [University of Tokushima, Department of Electrical and Electronic Engineering, Tokushima (Japan); Teramoto, Y.; Katsuki, S.; Akiyama, H. [Kumamoto University, Department of Electrical and Computer Engineering, Kumamoto (Japan)

    2001-09-01

    Although considerable investigations have been reported on z-pinches to achieve nuclear fusion, little attention has been given from the point of view of how a wire array consisting of many parallel wires explodes. Instability existing in the wire array discharge has been shown. In this paper, the effect of wire shape in the wire array on unstable behavior of the wire array discharge is represented by numerical analysis. The claws on the wire formed in installation of wire may cause uniform current distribution on wire array. The effect of error of wire diameter in production is computed by Monte Carlo Method. (author)

  5. Effect of wire shape on wire array discharge

    International Nuclear Information System (INIS)

    Shimomura, N.; Tanaka, Y.; Yushita, Y.; Nagata, M.; Teramoto, Y.; Katsuki, S.; Akiyama, H.

    2001-01-01

    Although considerable investigations have been reported on z-pinches to achieve nuclear fusion, little attention has been given from the point of view of how a wire array consisting of many parallel wires explodes. Instability existing in the wire array discharge has been shown. In this paper, the effect of wire shape in the wire array on unstable behavior of the wire array discharge is represented by numerical analysis. The claws on the wire formed in installation of wire may cause uniform current distribution on wire array. The effect of error of wire diameter in production is computed by Monte Carlo Method. (author)

  6. Towards plant wires

    OpenAIRE

    Adamatzky, Andrew

    2014-01-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self...

  7. Photovoltaic Wire, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  8. Charpak hemispherical wire chamber

    CERN Multimedia

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  9. DRG systém v ČR

    OpenAIRE

    Hodyc, Daniel MUDr.

    2007-01-01

    Diplomová práce hodnotí historický proces implementace klasifikačního systému DRG v České republice a srovnává jej s vývojem analogických systémů v ostatních zemích světa. Na podkladě platné metodiky IR DRG užívané v ČR v roce 2006 analyzuje hospitalizační část lékařské péče poskytované ve Fakultní nemocnici v Motole. Zkoumá rozdíly v nákladovosti při srovnání rozdílných pacientských skupin (děti – dospělí, operovaní – léčení konzervativně) a ukazuje výhody užití DRG systému pro hodnocení kva...

  10. 1998 wire development workshop proceedings

    International Nuclear Information System (INIS)

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development

  11. 1998 wire development workshop proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development.

  12. Wire Array Photovoltaics

    Science.gov (United States)

    Turner-Evans, Dan

    Over the past five years, the cost of solar panels has dropped drastically and, in concert, the number of installed modules has risen exponentially. However, solar electricity is still more than twice as expensive as electricity from a natural gas plant. Fortunately, wire array solar cells have emerged as a promising technology for further lowering the cost of solar. Si wire array solar cells are formed with a unique, low cost growth method and use 100 times less material than conventional Si cells. The wires can be embedded in a transparent, flexible polymer to create a free-standing array that can be rolled up for easy installation in a variety of form factors. Furthermore, by incorporating multijunctions into the wire morphology, higher efficiencies can be achieved while taking advantage of the unique defect relaxation pathways afforded by the 3D wire geometry. The work in this thesis shepherded Si wires from undoped arrays to flexible, functional large area devices and laid the groundwork for multijunction wire array cells. Fabrication techniques were developed to turn intrinsic Si wires into full p-n junctions and the wires were passivated with a-Si:H and a-SiNx:H. Single wire devices yielded open circuit voltages of 600 mV and efficiencies of 9%. The arrays were then embedded in a polymer and contacted with a transparent, flexible, Ni nanoparticle and Ag nanowire top contact. The contact connected >99% of the wires in parallel and yielded flexible, substrate free solar cells featuring hundreds of thousands of wires. Building on the success of the Si wire arrays, GaP was epitaxially grown on the material to create heterostructures for photoelectrochemistry. These cells were limited by low absorption in the GaP due to its indirect bandgap, and poor current collection due to a diffusion length of only 80 nm. However, GaAsP on SiGe offers a superior combination of materials, and wire architectures based on these semiconductors were investigated for multijunction

  13. Componentes biol??gicamente activos de la leche materna

    OpenAIRE

    Bar?? Rodr??guez, Luis; Jim??nez, J.; Mart??nez-F??rez, Antonio; Boza Puerta, Julio Jos??

    2001-01-01

    La leche materna es un complejo fluido biol??gico que aporta la energ??a y los nutrientes esenciales para el desarrollo y crecimiento del reci??n nacido. Pero adem??s, la leche materna contiene toda una serie de compuestos bioactivos como enzimas, hormonas, factores de crecimiento, prote??nas espec??ficas, poliaminas, nucle??tidos, oligosac??ridos, etc., que ejercen efectos biol??gicos y que en conjunto reciben el nombre de ???factores tr??ficos de la leche???. Estos compuestos bi...

  14. Commercial and Industrial Wiring.

    Science.gov (United States)

    Kaltwasser, Stan; Flowers, Gary

    This module is the third in a series of three wiring publications, includes additional technical knowledge and applications required for job entry in the commercial and industrial wiring trade. The module contains 15 instructional units that cover the following topics: blueprint reading and load calculations; tools and equipment; service;…

  15. Towards plant wires.

    Science.gov (United States)

    Adamatzky, Andrew

    2014-08-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self-growing wetware circuits and devices, and integration of plant-based electronic components into future and emergent bio-hybrid systems. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  16. Thermosonic wire bonding of IC devices using palladium wire

    International Nuclear Information System (INIS)

    Shze, J.H.; Poh, M.T.; Tan, R.M.

    1996-01-01

    The feasibility of replacing gold wire by palladium wire in thermosonic wire bonding of CMOS and bipolar devices are studied in terms of the manufacturability, physical, electrical and assembly performance. The results that palladium wire is a viable option for bonding the bipolar devices but not the CMOS devices

  17. Wire chambers: Trends and alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Regler, Meinhard

    1992-05-15

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!.

  18. Système de guidage pour ponts roulants

    CERN Document Server

    Caldérone, A

    1999-01-01

    L'équipe de maintenance des ponts roulants ST-HM-PR est souvent confrontée à résoudre des problèmes d'usure de galets de translation. Ces défauts apparaissent particulièrement lorsque l'on travaille avec des charges décentrées et sur des ponts roulants de grande portée. Pour remédier à ces défauts, plutôt que d'utiliser une solution mécanique conventionnelle, le groupe HM a développé un système électronique qui consiste à mesurer la distance entre le rail de roulement et les joues des roues, traiter ce signal et corriger la vitesse des moteurs respectifs de translation, de façon à maintenir le pont roulant centré. Ce système a été entièrement réalisé au sein du groupe HM et installé sur deux ponts roulants équipant le hall EHN1.

  19. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  20. Un Nobel para el tiempo biológico

    Directory of Open Access Journals (Sweden)

    Diego Golombek

    2018-01-01

    Full Text Available El premio Nobel en Fisiología o Medicina de 2017 fue otorgado a tres investigadores norteamericanos pioneros en el descubrimiento del mecanismo de los ritmos circadianos. Ya era hora… y es una excelente excusa para destacar la importancia de la Cronobiología – la ciencia que estudia los ritmos y relojes biológicos - tanto en la vida cotidiana en general como en las ciencias médicas en particular.

  1. Biolingüística y capacidad humana

    Directory of Open Access Journals (Sweden)

    Chomsky Noam Abraham

    2006-06-01

    Full Text Available Este artículo presenta de manera sucinta el enfoque llamado 'biolingüístico' que empezó a desarrollarse en los primeros años de la posguerra, teniendo en cuenta los avances de la biología y las matemáticas. Se pasa revista a algunos postulados de la neurociencia (i.e. ciencia cognitiva en lo concerniente a la 'facultad del lenguaje', así como a los dos últimos modelos de la GG: el modelo de 'Principios y Parámetros' (P&P y el modelo 'Minimalista'. Estos últimos buscan responder las cuestiones fundamentales de la biología del lenguaje, su naturaleza, uso y evolución. Desde este punto de vista, se trata de caracterizar el equipamiento biológico gracias al cual los seres humanos adquieren una gramática. Así las cosas, se considera el equipamiento biológico como una función que asocia experiencia y gramática.

  2. Evaluation of biol`s effect on fourteen accession of native potato (Solanum ssp. at the experimental station kallutaca

    Directory of Open Access Journals (Sweden)

    Condori-Mamani Pastor

    2017-05-01

    Full Text Available In Bolivia the productive potato regions, you characterize for an extensive agriculture in blankets (of traditional form, of car subsistence and not much diversified, the little properties for the cultivation of potato possess the greater part of the productive, and they locate at little plots of land that annually they go rotating. The present research work has the objective to make a comparison and to characterize fourteen accessions of native potato of germoplasma's collection, of Agronomic Ingeniería's race, (UPEA. The study carried completion at Kallutaca's experiment station itself, becoming established on the basis of a Design Bloques Complete at random (DBCA with three repetitions each accession, the second factor is diligent biol's dose, considered himself like a stimulant compound fito, for cultivations, where increments in the capability of photosynthesis and the production allow principal. Whose moral values place between 2.0 2.6% themselves (% in dry material and that they yielded 3.3 %'s concentration of total N to 3.7%. The analysis of microcomputer Hierro's (132 ppm, Manganeso's, Cobre's and Zinc's presence with 12.1 and 6 ppm detected nutrient in the obtained effluent. Accessions Pole, Sacampaya, Sani imilla, Janq'o, collide, Runic Bola, Q'aysalla and Laramq'aysa had bigger development, the same the remainders have bigger performances they did not have the same incidence. This answer is due to a positive effect of the biol on the performance of tubers in accordance with dose of diligent biol the accessions of native potato where 1 with the application of dose of 25 % of Biol obtained to 10 t.h-1 an equivalent yield.

  3. Gouvernance des systèmes alimentaires urbains pour la prévention ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    ... contre ces systèmes alimentaires en évolution et l'augmentation connexe des maladies ... les systèmes d'information et d'enregistrement des faits d'état civil dans les pays en ... GrowInclusive : la plateforme tant attendue est en construction.

  4. Analyste de systèmes intermédiaire (h/f) | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    L'analyste de systèmes intermédiaire travaille sous la supervision du ... à la mise en œuvre et à la maintenance d'un large éventail de systèmes tout en assurant ... directement les consultants externes sous contrat afin de faciliter la transition ...

  5. Systèmes d'information sanitaire ou santé sexuelle et reproductive ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    23 mai 2017 ... Systèmes d'information sanitaire ou santé sexuelle et reproductive des adolescents en Afrique de l'Ouest. Appel. Propositions. Programme(s) ... Sujet(s). Systèmes de santé, ADOLESCENTS, SANTÉ REPRODUCTIVE, DROITS EN MATIERE DE PROCREATION. Durée. 36 à 48 mois. Financée par. CRDI ...

  6. Influence du système d'élevage sur la reproduction de la poule ...

    African Journals Online (AJOL)

    SARAH

    améliorer la productivité des poules locales. Le nombre d'œufs pondu par poule et par an dans ce système a été plus du ... moderne de poulet de chair, de poules pondeuses ..... conditionnée plus par le système de conduite et la.

  7. Wire core reactor for NTP

    International Nuclear Information System (INIS)

    Harty, R.B.

    1991-01-01

    The development of the wire core system for Nuclear Thermal Propulsion (NTP) that took place from 1963 to 1965 is discussed. A wire core consists of a fuel wire with spacer wires. It's an annular flow core having a central control rod. There are actually four of these, with beryllium solid reflectors on both ends and all the way around. Much of the information on the concept is given in viewgraph form. Viewgraphs are presented on design details of the wire core, the engine design, engine weight vs. thrust, a technique used to fabricate the wire fuel element, and axial temperature distribution

  8. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...... new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as “wired to freedom,” we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear...

  9. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  10. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  11. Wired vs. Wireless.

    Science.gov (United States)

    Fielding, Randall

    2000-01-01

    Presents a debate on which technology will be in tomorrow's classrooms and the pros and cons of wiring classrooms and using a wireless network. Concluding comments address the likelihood, and desirability, of placing computers throughout the entire educational process and what types of computers and capabilities are needed. (GR)

  12. A World without Wires

    Science.gov (United States)

    Panettieri, Joseph C.

    2006-01-01

    The wireless bandwagon is rolling across Mississippi, picking up a fresh load of converts and turning calamity into opportunity. Traditional wired school networks, many of which unraveled during Hurricane Katrina, are giving way to advanced wireless mesh networks that frequently include voice-over-IP (VoIP) capabilities. Vendor funding is helping…

  13. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and have...

  14. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  15. Wire EDM for Refractory Materials

    Science.gov (United States)

    Zellars, G. R.; Harris, F. E.; Lowell, C. E.; Pollman, W. M.; Rys, V. J.; Wills, R. J.

    1982-01-01

    In an attempt to reduce fabrication time and costs, Wire Electrical Discharge Machine (Wire EDM) method was investigated as tool for fabricating matched blade roots and disk slots. Eight high-strength nickel-base superalloys were used. Computer-controlled Wire EDM technique provided high quality surfaces with excellent dimensional tolerances. Wire EDM method offers potential for substantial reductions in fabrication costs for "hard to machine" alloys and electrically conductive materials in specific high-precision applications.

  16. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  17. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  18. Control biológico de ácaros Tetranychidae

    Directory of Open Access Journals (Sweden)

    Acosta Gómez Alfredo

    1992-12-01

    Full Text Available En este articulo, se presenta información publicada e inédita y, también, se realiza una revisión bibliográfica exhaustiva de los enemigos naturales de T. cinnabarinus y T. urticae, tanto a nivel mundial, como a nivel nacional, con el propósito de despertar el interés e informar sobre las bondades del control
    biológico de los ácaros Tetranychidae y, en los casos donde es posible, se proporciona alguna información correspondiente a su efectividad. Posteriormente, se plantea una discusión resumida y se sugieren algunas propuestas de comportamiento estratégico o de utilidad potencial que podrían ser adoptadas por los profesionales comprometidos o
    responsables de los cultivos de flores para promover
    la ampliación del uso de enemigos naturales de los ácaros y utilizar, entre otros, métodos o estrategias biológicas, culturales o flsicas, que ayuden a disminuir la frecuencia del uso de agroquímicos y, así, conservar un ambiente menos contaminado y menos perjudicial para la humanidad del futuro.

  19. Webový systém pro skladovou evidenci

    OpenAIRE

    Češka, Petr

    2015-01-01

    Cílem diplomové práce je zhodnotit a vylepšit aktuální řešení informačního systému organizace Klub Salesiánského hnutí mládeže v Prostějově tak, aby splňoval náročnější požadavky na rychlou online komunikaci a vytvořil tak dostupnou podporu pro řízení informací a řízení skladových aktiv. Práce se zaměřuje na další návrhy rozšíření IS tak, aby se na jeho základech mohla organizace dále rozvíjet a plnit požadavky udávané stakeholdery. The aim of the diploma thesis is to evaluate and improve ...

  20. GPS sledovací systém

    OpenAIRE

    Hofman, Jan

    2010-01-01

    V práci je popsán základní princip a vlastnosti globálního pozičního systému GPS. Je zde přiblížena problematika určování polohy, rychlosti a nadmořské výšky. Tyto poznatky jsou dále použity pro návrh zařízení, které komunikuje s běžně vyráběným GPS přijímačem a z něj získané informace zpracovává a ukládá do paměti pro pozdější vyhodnocení The keystone and properties of Global Position System (GPS) are described in this thesis. The thesis explains questions of position, speed and elevation...

  1. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  2. The Micro Wire Detector

    International Nuclear Information System (INIS)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M.; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C.

    1999-01-01

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 μm 2 apertures, crossed by 25 μm anode strips to which it is attached by 50 μm kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  3. Superconducting magnet wire

    Science.gov (United States)

    Schuller, Ivan K.; Ketterson, John B.; Banerjee, Indrajit

    1986-01-01

    A superconducting tape or wire with an improved critical field is formed of alternating layers of a niobium-containing superconductor such as Nb, NbTi, Nb.sub.3 Sn or Nb.sub.3 Ge with a thickness in the range of about 0.5-1.5 times its coherence length, supported and separated by layers of copper with each copper layer having a thickness in the range of about 170-600 .ANG..

  4. Twisting wire scanner

    Energy Technology Data Exchange (ETDEWEB)

    Gharibyan, V.; Delfs, A.; Koruptchenkov, I.; Noelle, D.; Tiessen, H.; Werner, M.; Wittenburg, K.

    2012-11-15

    A new type of 'two-in-one' wire scanner is proposed. Recent advances in linear motors' technology make it possible to combine translational and rotational movements. This will allow to scan the beam in two perpendicular directions using a single driving motor and a special fork attached to it. Vertical or horizontal mounting will help to escape problems associated with the 45 deg scanners. Test results of the translational part with linear motors is presented.

  5. Twisting wire scanner

    International Nuclear Information System (INIS)

    Gharibyan, V.; Delfs, A.; Koruptchenkov, I.; Noelle, D.; Tiessen, H.; Werner, M.; Wittenburg, K.

    2012-11-01

    A new type of 'two-in-one' wire scanner is proposed. Recent advances in linear motors' technology make it possible to combine translational and rotational movements. This will allow to scan the beam in two perpendicular directions using a single driving motor and a special fork attached to it. Vertical or horizontal mounting will help to escape problems associated with the 45 deg scanners. Test results of the translational part with linear motors is presented.

  6. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  7. Soutien au programme de recherche du GCRAI sur les systèmes d ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Plus de 700 millions de personnes dépendent de systèmes d'aquaculture pour gagner leur vie. Ces systèmes agricoles diversifiés combinent culture, élevage, aquaculture, pêche et collecte de ressources naturelles comme les fruits, les graines, le bois et la faune. Toutefois, de nombreuses contraintes empêchent les petits ...

  8. Schéma directeur des Systèmes d'information 2012-2016

    OpenAIRE

    Institut National de Recherche Agronomique UAR 0776 Administration du siège

    2012-01-01

    Le schéma directeur des systèmes d’information de l’inra est le premier Schéma directeur dont l’institut se dote dans le champ des systèmes D’information. Il couvre la période 2012‐2016 du contrat d’objectifs Et s’inscrit dans les perspectives scientifiques dressées par le document D’orientation 2010‐2020

  9. Un système multi-agents pour le filtrage automatique du courrier ...

    African Journals Online (AJOL)

    Cet article montre l'applicabilité et l'adaptabilité de l'appriche intelligence artificielle distribuée, en l'occurrence les systèmes multi-agnets, au filtrage du courrier électronique. Il décrit un système de filtrage de courriers électroniques dynamiques et intelligent (SYMCOL). Il permet de traiter la partie structurée et la partie texte ...

  10. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  11. Right wire in orthodontics: a review

    OpenAIRE

    Ali, Hashim

    2015-01-01

    Quality of orthodontic wire such as stiffness, hardness, resiliency, elasticity and working range are important determinants of the effectivenes of tooth movement. Commonly used types of orthodontic arch wire:1) stainless steel(ss) wire, 2) conventional nickel- titanium (NiTi)alloy wire,3) improved super elastic NiTi- alloy wire( also called low hysteresis(LH)wire), and titanium molybdenum alloy(TMA) wire.

  12. Review of wire chamber aging

    International Nuclear Information System (INIS)

    Va'Vra, J.

    1986-02-01

    This paper makes an overview of the wire chamber aging problems as a function of various chamber design parameters. It emphasizes the chemistry point of view and many examples are drawn from the plasma chemistry field as a guidance for a possible effort in the wire chamber field. The paper emphasizes the necessity of variable tuning, the importance of purity of the wire chamber environment, as well as it provides a practical list of presently known recommendations. In addition, several models of the wire chamber aging are qualitatively discussed. The paper is based on a summary talk given at the Wire Chamber Aging Workshop held at LBL, Berkeley on January 16-17, 1986. Presented also at Wire Chamber Conference, Vienna, February 25-28, 1986. 74 refs., 18 figs., 11 tabs

  13. Wire communication engineering

    International Nuclear Information System (INIS)

    Son, Byeong Tae

    1997-02-01

    This book describes wire telecommunication engineering/ It is divided into eleven chapter, which deal with Introduction with development of telecommunication, voice and sound wave and communication network, Telegraphy with summary of telegraphy, code of telegraphy, communication speed, morse and telex, Telephone on structure, circuit and image telephone, Traffic on telecommunication traffic, transmission of line about theory, cable line and loaded cable, carrier communication with carrier telegraphy and carrier telephone, optical communication with types, structure, specialty, laser and equipment, DATA, Mobile telecommunication on summary, mobile telephone, radio paging and digital mobile telecommunication, ISDN with channel of ISDN, and service of ISDN, and design of telecommunication.

  14. The Micro Wire Detector

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M. E-mail: maximo.plo@cern.ch; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C

    1999-10-11

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 {mu}m{sup 2} apertures, crossed by 25 {mu}m anode strips to which it is attached by 50 {mu}m kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  15. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  16. Stabilized superconductive wires

    International Nuclear Information System (INIS)

    Randall, R.N.; Wong, J.

    1976-01-01

    A stable, high field, high current conductor is produced by packing multiple, multi-layer rods of a bronze core and niobium or vanadium inner jacket and copper outer jacket into a pure copper tube or other means for forming a pure copper matrix, sealing, working the packed tube to a wire, and by diffusion, heat treating to form a type II superconducting, Beta-Wolfram structure, intermetallic compound as a layer within each of several filaments derived from the rods. The layer of Beta-Wolfram structure compound may be formed in less than 2 h of diffusion heat treatment in a thickness of 0.5--2μ

  17. Diagnostics for exploding wires (abstract)

    International Nuclear Information System (INIS)

    Moosman, B.; Bystritskii, V.; Wessel, F.J.; Van Drie, A.

    1999-01-01

    Two diagnostics, capable of imaging fast, high temperature, plasmas were used on exploding wire experiments at UC Irvine. An atmospheric pressure nitrogen laser (λ=337.1 nm) was used to generate simultaneous shadow and shearing interferogram images with a temporal resolution of ∼1 ns and a spatial resolution of 10 μm. An x-ray backlighter imaged the exploding wire 90 degree with respect to the laser and at approximately the same instant in time. The backlighter spatial resolution as determined by geometry and film resolution was 25 μm. Copper wires of diameters (25, 50, and 100 μm) and steel wire d=25 μm were exploded in vacuum (10 -5 Torr) at a maximum current level of 12 kA, by a rectified marx bank at a voltage of 50 kV and a current rise time (quarter period) of 900 ns. Copper wires which were cleaned and then resistively heated under vacuum to incandescence for several hours prior to high current initiation, exhibited greater expansion velocities at peak current than wires which had not been heated prior to discharge. Axial variations on the surface of the wire observed with the laser were found to correlate with bulk axial mass differences from x-ray backlighting. High electron density, measured near the opaque surface of the exploding wire, suggests that much of the current is shunted outward away from the bulk of the wire. copyright 1999 American Institute of Physics

  18. Reliability Criteria for Thick Bonding Wire.

    Science.gov (United States)

    Dagdelen, Turker; Abdel-Rahman, Eihab; Yavuz, Mustafa

    2018-04-17

    Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.

  19. Reliability Criteria for Thick Bonding Wire

    Directory of Open Access Journals (Sweden)

    Turker Dagdelen

    2018-04-01

    Full Text Available Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al and aluminum coated copper (CucorAl wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire.

  20. Reliability Criteria for Thick Bonding Wire

    Science.gov (United States)

    Yavuz, Mustafa

    2018-01-01

    Bonding wire is one of the main interconnection techniques. Thick bonding wire is widely used in power modules and other high power applications. This study examined the case for extending the use of traditional thin wire reliability criteria, namely wire flexure and aspect ratio, to thick wires. Eleven aluminum (Al) and aluminum coated copper (CucorAl) wire samples with diameter 300 μm were tested experimentally. The wire response was measured using a novel non-contact method. High fidelity FEM models of the wire were developed and validated. We found that wire flexure is not correlated to its stress state or fatigue life. On the other hand, aspect ratio is a consistent criterion of thick wire fatigue life. Increasing the wire aspect ratio lowers its critical stress and increases its fatigue life. Moreover, we found that CucorAl wire has superior performance and longer fatigue life than Al wire. PMID:29673194

  1. Vibration of signal wires in wire detectors under irradiation

    International Nuclear Information System (INIS)

    Bojko, I.R.; Shelkov, G.A.; Dodonov, V.I.; Ignatenko, M.A.; Nikolenko, M.Yu.

    1995-01-01

    Radiation-induced vibration of signal wires in wire detectors is found and explained. The phenomenon is based on repulsion of a signal wire with a positive potential and a cloud of positive ions that remains after neutralization of the electron part of the avalanche formed in the course of gas amplification. Vibration with a noticeable amplitude may arise from fluctuations of repulsive forces, which act on the wire and whose sources are numerous ion clusters. A formula is obtained which allows wire oscillations to be estimated for all types of wire detectors. Calculation shows that oscillations of signal wires can be substantial for the coordinate accuracy of a detector working in the limited streamer mode at fluxes over 10 5 particles per second per wire. In the proportional mode an average oscillation amplitude can be as large as 20-30 μm at some detector parameters and external radiation fluxes over 10 5 . The experimental investigations show that the proposed model well describes the main features of the phenomenon. 6 refs., 8 figs

  2. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  3. Improved superconducting magnet wire

    Science.gov (United States)

    Schuller, I.K.; Ketterson, J.B.

    1983-08-16

    This invention is directed to a superconducting tape or wire composed of alternating layers of copper and a niobium-containing superconductor such as niobium of NbTi, Nb/sub 3/Sn or Nb/sub 3/Ge. In general, each layer of the niobium-containing superconductor has a thickness in the range of about 0.05 to 1.5 times its coherence length (which for Nb/sub 3/Si is 41 A) with each copper layer having a thickness in the range of about 170 to 600 A. With the use of very thin layers of the niobium composition having a thickness within the desired range, the critical field (H/sub c/) may be increased by factors of 2 to 4. Also, the thin layers of the superconductor permit the resulting tape or wire to exhibit suitable ductility for winding on a magnet core. These compositions are also characterized by relatively high values of critical temperature and therefore will exhibit a combination of useful properties as superconductors.

  4. Amélioration du système de suivi de l'information sur la santé ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Le système de suivi de l'information sur la santé communautaire (CHITS) est un système électronique d'information sur la santé publique mis en place par les services de santé de Pasay City en 2004. Le cinquième des habitants des bidonvilles du grand Manille étant établis à Pasay City, ce système dessert une population ...

  5. Las armas biológicas. Perspectivas de futuro

    Directory of Open Access Journals (Sweden)

    Nieva Machín

    2014-05-01

    Full Text Available La valoración de bajo riesgo de sufrir un ataque con armas biológicas realizada por la estrategia nacional de seguridad resulta errónea ya que España como miembro de la OTAN debería recoger en su estrategia nacional de seguridad del año 2013 esta amenaza ya considerada como tal por la OTAN en el año 2002. Para una valoración efectiva del nivel de esta amenaza resulta preciso considerar que esta ha trascendido el ámbito militar. En el presente artículo se presentará la vulnerabilidad de España derivaba de las políticas y protocolos de seguridad de carácter reactivo y no preventivo establecidas en España así como aspectos mutidimensionales que requieren un replanteamiento y mejoras acordes a una valoración de riesgo más precisa.

  6. Welding wire pressure sensor assembly

    Science.gov (United States)

    Morris, Timothy B. (Inventor); Milly, Peter F., Sr. (Inventor); White, J. Kevin (Inventor)

    1994-01-01

    The present invention relates to a device which is used to monitor the position of a filler wire relative to a base material being welded as the filler wire is added to a welding pool. The device is applicable to automated welding systems wherein nonconsumable electrode arc welding processes are utilized in conjunction with a filler wire which is added to a weld pool created by the electrode arc. The invention senses pressure deviations from a predetermined pressure between the filler wire and the base material, and provides electrical signals responsive to the deviations for actuating control mechanisms in an automatic welding apparatus so as to minimize the pressure deviation and to prevent disengagement of the contact between the filler wire and the base material.

  7. Forming Refractory Insulation On Copper Wire

    Science.gov (United States)

    Setlock, J.; Roberts, G.

    1995-01-01

    Alternative insulating process forms flexible coat of uncured refractory insulating material on copper wire. Coated wire formed into coil or other complex shape. Wire-coating apparatus forms "green" coat on copper wire. After wire coiled, heating converts "green" coat to refractory electrical insulator. When cured to final brittle form, insulating material withstands temperatures above melting temperature of wire. Process used to make coils for motors, solenoids, and other electrical devices to be operated at high temperatures.

  8. Control wiring diagrams

    International Nuclear Information System (INIS)

    McCauley, T.M.; Eskinazi, M.; Henson, L.L.

    1989-01-01

    This paper discusses the changes in electrical document requirements that occur when construction is complete and a generating station starts commercial operation. The needs of operations and maintenance (O and M) personnel are analyzed and contrasted with those of construction to illustrate areas in which the construction documents (drawings, diagrams, and databases) are difficult to use for work at an operating station. The paper discusses the O and M electrical documents that the Arizona Nuclear Power Project (ANPP) believes are most beneficial for the three operating units at Palo Verde; these are control wiring diagrams and an associated document cross-reference list. The benefits offered by these new, station O and M-oriented documents are weighted against the cost of their creation and their impact on drawing maintenance

  9. Electroplated superconducting wire

    International Nuclear Information System (INIS)

    Peger, C.H.

    1991-01-01

    A hard chromium solution has been considered the least efficient of all plating solutions. This is not exactly true if the correct plating conditions are used. The accepted efficiency is only 12% but that is only true for the parameters that were used long ago to make the determination. At 12% efficiency it would be impossible to plate Superconductor wire. The world's chromium plating shops have been plating at a .001 (.025u) per hour rate since the turn of the century. Shops in the Cleveland, Ohio area have been limiting their plating rate to .006 (152u) since 1935. A few have used .012 (304u) to .030 (762u) per hour for specialized jobs. These figures would indicate the apparent efficiency of the old 100 to 1 chromium, sulfate solution can be higher than 60%. The industry uses a 3 bus bar tank with wide spacing between anode and cathode. This results in high solution resistance and high heat generation and consequently slow plating rates. The Reversible Rack 2 Bus Bar System uses very close anode to cathode spacings. This results in the high plating rates with improved quality deposits. When first asked to chromium plate pure nickel wire reel to reel in long lengths, companies making reel to reel machines were asked if chromium plating was practical. In every case, the answer was it couldn't be done. Gold, tin and zinc plating was being done reel to reel. Using the same parameters that were used to determine a chromium solution efficiency was only 12%, these other metal solutions check out close to 100%

  10. Cadenas de valor, comercio exterior y diversidad biológica

    OpenAIRE

    Gómez, Rosario

    2014-01-01

    En el Perú, gradualmente se aprecia la articulación entre mercados emergentes y cadenas de valor nacionales, vinculadas con el aprovechamiento sostenible de la diversidad biológica. En este sentido, la megadiversidad biológica y, por ende, los servicios que brindan los ecosistemas han contribuido a responder a las oportunidades que brinda el mercado internacional. En dicho contexto, este artículo tiene como objetivo analizar el aporte económico de la diversidad biológica, en particular en ...

  11. Aplikace pro nositelnou elektroniku se systémem Android Wear

    OpenAIRE

    Šmejkal, Petr

    2017-01-01

    Semestrální práce „Aplikace pro nositelnou elektroniku se systémem" Android Wear popisuje základní principy komunikačních sítí - M2M (machine to machine), H2H (human to human) a D2D (device to device). Práce se dále zabývá nositelnými zařízeními, zejména chytrými hodinkami, dostupnými operačními systémy pro chytré hodinky a systémem Android, Android Wear. V praktické části je popsaná funkcionalita, vzhled a struktura vyvinuté aplikace pro Android Wear. The semestral project "Application fo...

  12. Informační systém pro předprodej vstupenek

    OpenAIRE

    Galetka, Josef

    2007-01-01

    Práce se zabývá problematikou spojenou s návrhem a implementací informačního systému pro předprodej vstupenek. Systém umožňuje prodej a nákup vstupenek na různé akce. Je schopen generovat a zasílat vstupenky elektronicky. Je zahrnuta administrátorská správa systému a požadované uživatelské prostředky. Implementace byla realizována za použití technologie PHP, MySQL a JavaScript na serveru Apache. This work deals with the problems connected with projection and implementation of information s...

  13. Inteligentní přístupový systém

    OpenAIRE

    Steingart, Viktor

    2017-01-01

    Práce se zabývá tvorbou autonomního vestavěného systému sloužícího jako přístupový systém postaveném na platformě ESP8266. Systém umožňuje přístup správce do administrátorského webového rozhraní pomocí mobilního telefonu. This thesis deals with the creation of an autonomous embedded system serving as an access control system built on the platform ESP8266. The system allows administrator access to the admin web interface via a mobile phone. B

  14. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  15. La systématique de l’esprit pratique chez Wolff, Kant, Fichte et Hegel

    OpenAIRE

    Siep, Ludwig

    2011-01-01

    En dépit des grands bouleversements systématiques dans la philosophie allemande du xviiie siècle, la continuité est étonnante, de Wolff à Hegel, pour ce qui concerne le contenu des doctrines sur la raison pratique. Une comparaison de ces doctrines chez Wolff, Kant, Fichte et Hegel peut révéler l’intention et les raisons pour lesquelles chacun de ces auteurs modifia la systématique des différentes facultés. À partir de Kant, autonomie et liberté deviennent les concepts directeurs permettant de...

  16. Reflexia na stav a perspektívy didaktiky biológie z pohľadu situácie na Prírodovedeckej fakulte Univerzity Komenského v Bratislave.

    Directory of Open Access Journals (Sweden)

    Katarína Ušáková

    2014-12-01

    Full Text Available Príspevok popisuje východiská a impulzy rozvoja didaktiky biológie na Slovensku  z pohľadu skúseností edukačnej a výskumnej práce na Katedre didaktiky prírodných vied, psychológie a pedagogiky PRIFUK v Bratislave. Cez stručný historický prehľad od povojnového obdobia až po súčasnosť upriamuje pozornosť na osobnosti, ktoré sú s formovaním didaktiky biológie úzko spojené. Poukazuje na niektoré spoločné problémy prírodovedného vzdelávania v kontexte spoločensko-politických zmien spojených so vstupom do EU a dôsledkami reformného úsilia s cieľom konvergencie vzdelávacích systémov krajín EU. Podrobnejšie sa venuje problémom v doktorandskom štúdiu  a výskumu v didaktike biológie, od kvality ktorého sa odvíja aj úroveň učiteľskej prípravy budúcich učiteľov biológie. Konkretizuje zmeny v obsahu aj v štruktúre didaktických predmetov s cieľom zvýšiť kvalitu a funkčnosť prípravy učiteľov. V závere príspevku autorka upozorňuje na pretrvávajúce problémy didaktiky biológie, ktorých riešenie si vyžaduje potrebu vyššej miery spolupráce všetkých zainteresovaných zložiek.

  17. Modeling birds on wires.

    Science.gov (United States)

    Aydoğdu, A; Frasca, P; D'Apice, C; Manzo, R; Thornton, J M; Gachomo, B; Wilson, T; Cheung, B; Tariq, U; Saidel, W; Piccoli, B

    2017-02-21

    In this paper we introduce a mathematical model to study the group dynamics of birds resting on wires. The model is agent-based and postulates attraction-repulsion forces between the interacting birds: the interactions are "topological", in the sense that they involve a given number of neighbors irrespective of their distance. The model is first mathematically analyzed and then simulated to study its main properties: we observe that the model predicts birds to be more widely spaced near the borders of each group. We compare the results from the model with experimental data, derived from the analysis of pictures of pigeons and starlings taken in New Jersey: two different image elaboration protocols allow us to establish a good agreement with the model and to quantify its main parameters. We also discuss the potential handedness of the birds, by analyzing the group organization features and the group dynamics at the arrival of new birds. Finally, we propose a more refined mathematical model that describes landing and departing birds by suitable stochastic processes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Inhomogeneous wire explosion in water

    International Nuclear Information System (INIS)

    Hwangbo, C.K.; Kong, H.J.; Lee, S.S.

    1980-01-01

    Inhomogeneous processes are observed in underwater copper wire explosion induced by a condensed capacitor discharge. The wire used is 0.1 mm in diameter and 10 mm long, and the capacitor of 2 μF is charged to 5 KV. A N 2 laser is used for the diagnostic of spatial extension of exploding copper vapour. The photographs obtained in this experiment show unambiguously the inhomogeneous explosion along the exploding wire. The quenching of plasma by the surrounding water inhibits the expansion of the vapour. It is believed the observed inhomogeneous explosion along the wire is located and localized around Goronkin's striae, which was first reported by Goronkin and discussed by Froengel as a pre-breakdown phenomenon. (author)

  19. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  20. Composite conductor containing superconductive wires

    Energy Technology Data Exchange (ETDEWEB)

    Larson, W.L.; Wong, J.

    1974-03-26

    A superconductor cable substitute made by coworking multiple rods of superconductive niobium--titanium or niobium--zirconium alloy with a common copper matrix to extend the copper and rods to form a final elongated product which has superconductive wires distributed in a reduced cross-section copper conductor with a complete metallurgical bond between the normal-conductive copper and the superconductor wires contained therein is described. The superconductor cable can be in the form of a tube.

  1. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  2. Wire Scanner Motion Control Card

    CERN Document Server

    Forde, S E

    2006-01-01

    Scientists require a certain beam quality produced by the accelerator rings at CERN. The discovery potential of LHC is given by the reachable luminosity at its interaction points. The luminosity is maximized by minimizing the beam size. Therefore an accurate beam size measurement is required for optimizing the luminosity. The wire scanner performs very accurate profile measurements, but as it can not be used at full intensity in the LHC ring, it is used for calibrating other profile monitors. As the current wire scanner system, which is used in the present CERN accelerators, has not been made for the required specification of the LHC, a new design of a wire scanner motion control card is part of the LHC wire scanner project. The main functions of this card are to control the wire scanner motion and to acquire the position of the wire. In case of further upgrades at a later stage, it is required to allow an easy update of the firmware, hence the programmable features of FPGAs will be used for this purpose. The...

  3. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  4. Administrateur du système (h/f) | CRDI - Centre de recherches pour ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Sous la supervision du gestionnaire, Infrastructure, sécurité et documents (ISD), ... et de la maintenance courants des divers systèmes d'infrastructure du Centre, ... techniques dans les régions et des techniciens sous contrat) pour fournir des ...

  5. Penser Système : Découvrir nos modèles d'organisation

    NARCIS (Netherlands)

    Bryan, B.; Goodman, M.; Schaveling, J.

    2011-01-01

    Pourquoi le travail s’accumule-t-il sur nos bureaux alors que nous travaillons de plus en plus? Parfois « nos solutions » aggravent nos problèmes. Comment pouvons-nous éviter ces paradoxes ? Penser système donne de nouvelles perspectives dans des situations complexes. Cela vous permettra de

  6. Mot du Directeur régional Pleins feux surla recherche des systèmes ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Gloria Lihemo

    Afrique sub-saharienne. Nous y parlons du travail que fait le. CRDI pour appuyer la recherche des systèmes sanitaires qui prend en compte une approche holistique, interdisciplinaire pour une meilleure santé. Le CRDI reconnaît ...

  7. Analyste de systèmes principal (h/f) | CRDI - Centre de recherches ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    L'analyste de systèmes principal travaille sous la supervision du ... une analyse fonctionnelle élémentaire des exigences en parlant de la portée et de la raison ... et l'infrastructure en matière de TI tout en se mettant à la place des techniciens, ...

  8. Gestionnaire, Systèmes financiers (h/f) | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Examiner et évaluer les répercussions des mises à niveau de l'infrastructure du CRDI .... Analyste des systèmes de gestion ... Le titulaire du poste établit le lien nécessaire entre les activités fonctionnelles financières et administratives et les ...

  9. A Syst-OMICS Approach to Ensuring Food Safety and Reducing the Economic Burden of Salmonellosis.

    NARCIS (Netherlands)

    Emond-Rheault, Jean-Guillaume; Jeukens, Julie; Freschi, Luca; Kukavica-Ibrulj, Irena; Boyle, Brian; Dupont, Marie-Josée; Colavecchio, Anna; Barrere, Virginie; Cadieux, Brigitte; Arya, Gitanjali; Bekal, Sadjia; Berry, Chrystal; Burnett, Elton; Cavestri, Camille; Chapin, Travis K; Crouse, Alanna; Daigle, France; Danyluk, Michelle D; Delaquis, Pascal; Dewar, Ken; Doualla-Bell, Florence; Fliss, Ismail; Fong, Karen; Fournier, Eric; Franz, Eelco; Garduno, Rafael; Gill, Alexander; Gruenheid, Samantha; Harris, Linda; Huang, Carol B; Huang, Hongsheng; Johnson, Roger; Joly, Yann; Kerhoas, Maud; Kong, Nguyet; Lapointe, Gisèle; Larivière, Line; Loignon, Stéphanie; Malo, Danielle; Moineau, Sylvain; Mottawea, Walid; Mukhopadhyay, Kakali; Nadon, Céline; Nash, John; Ngueng Feze, Ida; Ogunremi, Dele; Perets, Ann; Pilar, Ana V; Reimer, Aleisha R; Robertson, James; Rohde, John; Sanderson, Kenneth E; Song, Lingqiao; Stephan, Roger; Tamber, Sandeep; Thomassin, Paul; Tremblay, Denise; Usongo, Valentine; Vincent, Caroline; Wang, Siyun; Weadge, Joel T; Wiedmann, Martin; Wijnands, Lucas; Wilson, Emily D; Wittum, Thomas; Yoshida, Catherine; Youfsi, Khadija; Zhu, Lei; Weimer, Bart C; Goodridge, Lawrence; Levesque, Roger C

    2017-01-01

    The Salmonella Syst-OMICS consortium is sequencing 4,500 Salmonella genomes and building an analysis pipeline for the study of Salmonella genome evolution, antibiotic resistance and virulence genes. Metadata, including phenotypic as well as genomic data, for isolates of the collection are provided

  10. Le renforcement des systèmes de santé | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    4 avr. 2013 ... Avec le soutien du CRDI, Walter Flores et une coalition dirigée par le Centro de Estudios para la Equidad y Gobernanza en los Sistemas de Salud ... Les briques et les clics sont importants; il est essentiel de disposer d'infrastructures convenables et de systèmes efficaces de gestion de l'information.

  11. Elaboration et Suivi des Budgets de Marketing Industriel: le Système ADVISOR

    OpenAIRE

    Choffray, Jean-Marie; Delabre, Gilles

    1982-01-01

    Cet article revoit les problèmes posés par l'élaboration et le suivi des budgets de marketing dans un environnement industriel. Il présente le système ADVISOR pour lequel nous avons développé un programme interactif adapté aux besoins des entreprises Françaises.

  12. Les systèmes alimentaires alternatifs face aux enjeux sanitaires

    OpenAIRE

    Touzard, Jean-Marc

    2012-01-01

    L’objet de la communication est de montrer comment la coexistence et la combinaison d’une diversité de système alimentaires est un trait de la globalisation et joue sur les enjeux, les pratiques, et les régulations sanitaires.

  13. Systèmes de recommandation et Recherche d'Information

    OpenAIRE

    Candillier , Laurent; Chai , Etienne; Delpech , Estelle

    2012-01-01

    National audience; Cet article traite de l'application des technologies de recommandation aux systèmes de Recherche d'Information. Nous y détaillons un cas d'application à la recherche de lieux à travers la présentation de l'annuaire Nomao.

  14. Ignition and spread of electrical wire fires

    OpenAIRE

    Huang, Xinyan

    2012-01-01

    Ignition of electrical wires by external heating is investigated in order to gain a better understanding of the initiation of electrical-wire fires. An ignition-to- spread model is developed to systematically explain ignition and the following transition to spread. The model predicts that for a higher-conductance wire it is more difficult to achieve ignition and the weak flame may extinguish during the transition phase because of a large conductive heat loss along the wire core. Wires with tw...

  15. Systèmes coopératifs hybride Satellite-Terrestre : analyse de performance et dimensionnement du système

    OpenAIRE

    Sreng, Sokchenda

    2012-01-01

    Les systèmes de communications par satellite sont utilisés dans le contexte de la radiodiffusion, de la navigation, du sauvetage et du secours aux sinistrés, car ils permettent de fournir des services sur une large zone de couverture. Cependant, cette zone de couverture est limitée par l'effet de masquage provoqué par des obstacles qui bloquent la liaison directe entre le satellite et un utilisateur terrestre. L'effet de masquage devient plus sévère en cas de satellites à faibles angles d'élé...

  16. Technical innovation: Wire guided ductography

    International Nuclear Information System (INIS)

    Aslam, Muhammad Ovais; Ramadan, Salwa; Al-Adwani, Muneera

    2012-01-01

    To introduce an easy and improved technique for performing ductography using inexpensive easily available intravenous cannula. Guide wire: Prolene/Surgipro 3-0 (Polypropylene mono filament non-absorbable surgical suture). A plastic 26 G intravenous cannula. Disposable syringe 2 ml. Non-ionic contrast (low density like Omnipaque 240 mg I/I). The guide wire (Prolene 3-0) is introduced into the orifice of the duct heaving discharge and 26 G intravenous plastic cannula is then passed over the guide wire. The cannula is advanced in the duct over guide wire by spinning around it. When the cannula is in place the guide wire is removed. Any air bubbles present in the hub of the cannula can be displaced by filling the hub from bottom upwards with needle attached to contrast filled syringe. 0.2–0.4 ml non-ionic contrast is gently injected. Injection is stopped if the patient has pain or burning. Magnified cranio-caudal view is obtained with cannula tapped in place and gentle compression is applied with the patient sitting. If duct filling is satisfactory a 90* lateral view is obtained. A successful adaptation of the technique for performing ductography is presented. The materials required for the technique are easily available in most radiology departments and are inexpensive, thus making the procedure comfortable for the patient and radiologist with considerable cost effectiveness.

  17. Californium Recovery from Palladium Wire

    Energy Technology Data Exchange (ETDEWEB)

    Burns, Jon D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2014-08-01

    The recovery of 252Cf from palladium-252Cf cermet wires was investigated to determine the feasibility of implementing it into the cermet wire production operation at Oak Ridge National Laboratory’s Radiochemical Engineering Development Center. The dissolution of Pd wire in 8 M HNO3 and trace amounts of HCl was studied at both ambient and elevated temperatures. These studies showed that it took days to dissolve the wire at ambient temperature and only 2 hours at 60°C. Adjusting the ratio of the volume of solvent to the mass of the wire segment showed little change in the kinetics of dissolution, which ranged from 0.176 mL/mg down to 0.019 mL/mg. A successful chromatographic separation of 153Gd, a surrogate for 252Cf, from Pd was demonstrated using AG 50x8 cation exchange resin with a bed volume of 0.5 mL and an internal diameter of 0.8 cm.

  18. Initiatives canadiennes d'avant-garde en matière de systèmes de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Initiatives canadiennes d'avant-garde en matière de systèmes de santé équitables et d'amélioration de la santé des mères et des enfants ... renforcement des systèmes de santé : d'une part, le recrutement des travailleurs de la santé, le maintien de cet effectif et, d'autre part, le rôle des systèmes d'information sur la santé.

  19. Systèmes multi-échelles, Modélisation et simulation

    Science.gov (United States)

    Le Bris, Claude

    Systèmes multi-échelles est une introduction à la problématique des systèmes multi-échelles du point de vue du mathématicien appliqué. Il se compose d'une mosaique d'exemples dont le seul lien est d'appartenir à la très grande famille des problèmes issus de la physique au sens large qui présentent pour leur modélisation et leur simulation cette difficulté essentielle de comporter en leur sein des échelles de temps oud'espace très différentes.

  20. A Syst-OMICS Approach to Ensuring Food Safety and Reducing the Economic Burden of Salmonellosis

    Directory of Open Access Journals (Sweden)

    Jean-Guillaume Emond-Rheault

    2017-06-01

    Full Text Available The Salmonella Syst-OMICS consortium is sequencing 4,500 Salmonella genomes and building an analysis pipeline for the study of Salmonella genome evolution, antibiotic resistance and virulence genes. Metadata, including phenotypic as well as genomic data, for isolates of the collection are provided through the Salmonella Foodborne Syst-OMICS database (SalFoS, at https://salfos.ibis.ulaval.ca/. Here, we present our strategy and the analysis of the first 3,377 genomes. Our data will be used to draw potential links between strains found in fresh produce, humans, animals and the environment. The ultimate goals are to understand how Salmonella evolves over time, improve the accuracy of diagnostic methods, develop control methods in the field, and identify prognostic markers for evidence-based decisions in epidemiology and surveillance.

  1. Analyse des systèmes d'innovation (Burkina Faso) | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Ce projet a pour objectif d'améliorer l'efficience du système d'innovation en construction au Burkina Faso en renforçant les échanges entre chercheurs, inventeurs, ... Faso : communication présentée à la IIIe Conférence Internationale de KMA « Knowledge Management Africa » sous le thème « le... 49285. Journal articles.

  2. Architecture, des normes et des systèmes d'information libres, phase ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Architecture, des normes et des systèmes d'information libres, phase II (OASIS II) - Renforcement des capacités dans l'ensemble de l'Afrique. Sur presque tout le continent africain, la prestation des services de santé est limitée en raison des maigres ressources disponibles et de la charge de morbidité de plus en plus ...

  3. Armer les villes contre la faim : Systèmes alimentaires urbains ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Le XXe siècle a été le témoin d'une croissance massive des populations urbaines. ... On y explore le rôle que les structures existantes de marketing et de distribution peuvent jouer pour améliorer l'accessibilité, les systèmes de distribution alimentaire en émergence et leur apport éventuel à l'élimination de la faim dans les ...

  4. Consolidation des systèmes d'approvisionnement en Amérique ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Les technologies de l'information et de la communication (TIC) jouent un rôle clé dans la modernisation des systèmes d'administration publique, en général, ... Reporte final : VII Conferencia Anual sobre Compras Gubernamentales de las Américas, 18 al 20 de Octubre de 2011, Santo Domingo, República Dominicana.

  5. Systèmes d'information sur la santé

    International Development Research Centre (IDRC) Digital Library (Canada)

    personnel spécialisé — et bien souvent le leadership et la vision — pour ... Recourir aux données probantes pour réduire la mortalité maternelle au Nigeria. □ Incorporer les TIC aux systèmes de santé. □ Intégrer les collectivités à la surveillance du .... il y a lieu de mieux comprendre comment ces outils peuvent étayer la ...

  6. Influence du système de logement sur quelques performances ...

    African Journals Online (AJOL)

    Les effets de deux systèmes de logement (batterie de cages et sol sur litière) sur les performances zootechniques et économiques des poules pondeuses ont été évalués en zone tropicale humide, au sud du Benin. Un total de 180 poules pondeuses (Isa Brown) de 26 semaines d'âge était réparti en deux groupes de 108 et ...

  7. Mikrojádra operačních systémů

    OpenAIRE

    Beneš, Eduard

    2007-01-01

    Táto práca sa zaoberá problematikou mikrojadier operačných systémov. Prvá časť je zameraná na oboznámenie s problematikou jadier operačných systémov. Obsahuje základné vlastnosti a mechanizmy druhej generácie mikrojadier reprezentovanej mikrojadrom L4, na ktoré sa zameriavame v ďalších častiach práce. Následne sú opísané dva rôzne porty operačného systému Linux nad mikrojadro L4, sú to L4Linux a Wombat. V druhej časti práce je popísaný spôsob inštalácie vybraných portov a hlavné problémy, kto...

  8. Implementace protokolu ACP do operačního systému L4

    OpenAIRE

    Kolarík, Tomáš

    2012-01-01

    Práce se zabývá implementací protokolu ACP, který slouží k řízení přístupu pro operační systém založený na mikrojádře L4. Teoretická část práce se zabývá možnostmi řízení přístupu v počítačových sítích. Pozornost je se přitom soustřeďuje na AAA systémy, které řízení přístupu umožňují. Následně je podrobně popsán protokol ACP, typy jeho zpráv a reakce na ně. Druhá část teoretické přípravy je věnována operačním systémům kde se podrobněji zabývá jejich architekturou a službami. Následně je blíže...

  9. Optimalizace systému zaměstnaneckých benefitů v podniku

    OpenAIRE

    Knyblová, Lucie

    2009-01-01

    Cílem diplomové práce „Optimalizace systému zaměstnaneckých benefitů v podniku“ je analyzovat zaměstnanecké benefity dle současné právní úpravy z pohledu daňového zatížení podniku i zaměstnance. Dílčím cílem je na základě dotazníkového šetření zjistit spokojenost zaměstnanců se současným systémem zaměstnaneckých benefitů v konkrétním podniku a navrhnout určité změny, které povedou ke spokojenosti zaměstnanců a optimalizaci systému z daňového hlediska jak pro zaměstnance tak pro zaměstnavatele...

  10. Aislamiento de microorganismos para control biológico de Moniliophthora roreri

    OpenAIRE

    Liliana Yanet Suárez Contreras; Alba Luz Rangel Riaño

    2013-01-01

    Moniliophthora roreri es un hongo que causa la moniliasis, una enfermedad de la mazorca en el cultivo de cacao (Theobroma cacao), con pérdidas hasta del 60% de la cosecha. El control biológico utilizando microorganismos endófitos surge como una alternativa para el manejo de esta enfermedad. En la presente investigación se evaluaron microorganismos con potencial para control biológico de M. roreri en Norte de Santander, Colombia. Para el efecto, se aisló e identificó este fitopatógeno y se uti...

  11. Transparency in nanophotonic quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Mahi R [Department of Physics and Astronomy, University of Western Ontario, London N6A 3K7 (Canada)

    2009-03-28

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  12. Transparency in nanophotonic quantum wires

    International Nuclear Information System (INIS)

    Singh, Mahi R

    2009-01-01

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  13. Fabrication of tungsten wire needles

    International Nuclear Information System (INIS)

    Roder, A.

    1983-02-01

    Fine point needles for field emissoin are conventionally produced by electrolytically or chemically etching tungsten wire. Points formed in this manner have a typical tip radius of about 0.5 microns and a cone angle of some 30 degrees. The construction of needle matrix detector chambers has created a need for tungsten needles whose specifications are: 20 mil tungsten wire, 1.5 inch total length, 3 mm-long taper (resulting in a cone angle of about 5 degrees), and 25 micron-radius point (similar to that found on sewing needles). In the process described here for producing such needles, tungsten wire, immersed in a NaOH solution and in the presence of an electrode, is connected first to an ac voltage and then to a dc supply, to form a taper and a point on the end of the wire immersed in the solution. The process parameters described here are for needles that will meet the above specifications. Possible variations will be discussed under each approprite heading

  14. [Mechanics analysis of fracture of orthodontic wires].

    Science.gov (United States)

    Wang, Yeping; Sun, Xiaoye; Zhang, Longqi

    2003-03-01

    Fracture problem of orthodontic wires was discussed in this paper. The calculation formulae of bending stress and tensile stress were obtained. All main factors that affect bending stress and tensile stress of orthodontic wires were analyzed and discussed. It was concluded that the main causes of fracture of orthodontic wires were fatigue and static disruption. Some improving proposals for preventing fracture of orthodontic wires were put forward.

  15. 49 CFR 236.74 - Protection of insulated wire; splice in underground wire.

    Science.gov (United States)

    2010-10-01

    ... underground wire. 236.74 Section 236.74 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RULES, STANDARDS, AND INSTRUCTIONS GOVERNING... wire; splice in underground wire. Insulated wire shall be protected from mechanical injury. The...

  16. 49 CFR 234.241 - Protection of insulated wire; splice in underground wire.

    Science.gov (United States)

    2010-10-01

    ... underground wire. 234.241 Section 234.241 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION GRADE CROSSING SIGNAL SYSTEM SAFETY... of insulated wire; splice in underground wire. Insulated wire shall be protected from mechanical...

  17. Detection of a buried wire with two resistively loaded wire antennas

    NARCIS (Netherlands)

    Vossen, S.H.J.A.; Tijhuis, A.G.; Lepelaars, E.S.A.M.; Zwamborn, A.P.M.

    2002-01-01

    The use of two identical straight thin-wire antennas for the detection of a buried wire is analyzed with the aid of numerical calculations. The buried wire is located below an interface between two homogeneous half-spaces. The detection setup, which is formed by a transmitting and a receiving wire,

  18. One century of Kirschner wires and Kirschner wire insertion techniques : A historical review

    NARCIS (Netherlands)

    Franssen, Bas B. G. M.; Schuurman, Arnold H.; Van der Molen, Aebele Mink; Kon, Moshe

    A century ago, in 1909, Martin Kirschner (1879-942) introduced a smooth pin, presently known as the Kirschner wire (K-wire). The K-wire was initiallly used for skeletal traction and is now currently used for many different goals. The development of the K-wire and its insertion devices were mainly

  19. Pre-wired systems prove their worth.

    Science.gov (United States)

    2012-03-01

    The 'new generation' of modular wiring systems from Apex Wiring Solutions have been specified for two of the world's foremost teaching hospitals - the Royal London and St Bartholomew's Hospital, as part of a pounds sterling 1 billion redevelopment project, to cut electrical installation times, reduce on-site waste, and provide a pre-wired, factory-tested, power and lighting system. HEJ reports.

  20. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems...

  1. Getting "Wired" for McLuhan's Cyberculture.

    Science.gov (United States)

    McMurdo, George

    1995-01-01

    Examines the introduction of the computing magazine, "Wired", into the United Kingdom's (UK) market. Presents conversations with the founder and editorial staff of the UK edition, and discusses the accessibility of "Wired" via the World Wide Web. Describes 10 articles from United States "Wired" back-issues and…

  2. Un système d'avant-garde rend l'accès à l'information abordable ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    27 oct. 2010 ... Bien avant l'avènement des ordinateurs personnels et d'Internet, les énormes collections et bases de données des organismes des Nations Unies étaient consultables sous forme numérique par le truchement d'un système appelé ISIS. Par contre, ce système ne pouvant fonctionner qu'au moyen ...

  3. Intégration des pluies prévues du système AROME-PI dans le système AIGA

    OpenAIRE

    Demargne, J.; Javelle, P.

    2015-01-01

    / Cette étude a été réalisée pour le SCHAPI (Service Central d'Hydrométéorologie et d'Appui à la Prévision des Inondations) pour analyser l'amélioration du système d'avertissement sur la possibilité de crues rapides AIGA en intégrant des prévisions de pluie future à courte échéance et fine résolution spatio-temporelle et en prenant en compte leurs incertitudes. Le SCHAPI développe actuellement un service d'avertissement automatisé valable sur l'ensemble de la France, qui sera complété par un ...

  4. Intégration des pluies prévues du système COSMO-DE-EPS dans le système AIGA

    OpenAIRE

    Demargne, J.; Javelle, P.

    2014-01-01

    / Cette étude a été réalisée pour le SCHAPI (Service Central d'Hydrométéorologie et d'Appui à la Prévision des Inondations) pour analyser l'amélioration du système d'avertissement aux crues rapides AIGA en prenant en compte les incertitudes des pluies futures et des paramètres du modèle hydrologique calibré et régionalisé. Le SCHAPI développe actuellement un service d'avertissement automatisé valable sur l'ensemble de la France, qui sera complété par un service expertisé d'avertissement sur d...

  5. Clinical bending of nickel titanium wires

    Directory of Open Access Journals (Sweden)

    Stephen Chain

    2015-01-01

    Full Text Available Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our inventory but also customized the wire according to the treatment.

  6. Energy Deposition in a Septum Wire

    CERN Document Server

    Ferioli, G; Knaus, P; Koopman, J; CERN. Geneva. SPS and LHC Division

    2001-01-01

    The present note describes a machine development (MD) aimed to confirm experimentally the need for protection of the extraction wire septum ZS in SPS long straight section LSS6 during LHC operation. Single wires identical to the ones mounted on the extraction septum were fixed on a fast wire scanner and put into the beam path. The beam heated the wire until it broke after a measured number of turns. The maximum single shot intensity the septum wires could withstand was thus calculated and compared with simulation results.

  7. Griesinger e as bases da "Primeira psiquiatria biológica"

    Directory of Open Access Journals (Sweden)

    Mário Eduardo Costa Pereira

    2007-12-01

    Full Text Available Wilhelm Griesinger foi um personagem central na história da psiquiatria alemã. Considerado por muitos como um dos "pais da psiquiatria biológica", sua obra, na verdade, é extremamente complexa, apoiando-se em uma sofisticada teoria do eu e das desestruturação dos processos mentais na psicopatologia.

  8. História dos tratamentos biológicos Biologicals treatments's history

    Directory of Open Access Journals (Sweden)

    Sérgio Paulo Rigonatti

    2004-01-01

    Full Text Available Contexto: Trata-se de uma discussão de como surgiram os tratamentos biológicos no decorrer da história da psiquiatria.Context: It's about a discussion on how begun the biological treatment throughout Psychiatry History.

  9. Endocardite em prótese biológica por candida parapsilosis

    Directory of Open Access Journals (Sweden)

    Luiz Carlos Severo

    1987-02-01

    Full Text Available Relata-se um caso de endocardite causada pela Candida parapsilosis numa prótese valvular biológica em posição mitral. Revisa-se brevemente a literatura brasileira sobre o assunto.

  10. Electrodeposition of nickel nano wire arrays

    International Nuclear Information System (INIS)

    Nur Ubaidah Saidin; Kok Kuan Ying; Ng Inn Khuan; Nurazila Mat Zali; Siti Salwa Zainal Abidin

    2010-01-01

    Synthesis, characterization and assembly of one-dimensional nickel nano wires prepared by template directed electrodeposition are discussed in this paper. Parallel arrays of high aspect ratio nickel nano wires were electrodeposited using electrolytes with different cations and pH. The nano wires were characterized using X-ray diffractometry and scanning electron microscopy. It was found that the orientations of the electro deposited Ni nano wires were governed by the deposition current and the electrolyte conditions. Free standing nickel nano wires can be obtained by dissolving the template. Due to the magnetic nature of the nano wires, magnetic alignment was employed to assemble and position the free standing nano wires in the device structure. (author)

  11. Slice of LHC dipole wiring

    CERN Multimedia

    Dipole model slice made in 1994 by Ansaldo. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. 50’000 tonnes of steel sheets are used to make the magnet yokes that keep the wiring firmly in place. The yokes constitute approximately 80% of the accelerator's weight and, placed side by side, stretch over 20 km!

  12. Modifications in straight wire treatment.

    Science.gov (United States)

    Cardona, Alvin

    2010-01-01

    Orthodontic treatments have been modified with each new generation of clinicians. Today the emphasis is on facial esthetics and healthy temporomandibular joints. With orthopedic treatment, we can develop dental arches to get the necessary space to align the teeth and we can reach adequate function and esthetics, all within relatively good stability. By combining two-phase treatment with low friction fixed orthodontics and super elastic wires we produce light but continuous forces and we can provide better treatment than before. These types of forces cause physiological and functional orthopedic orthodontic reactions. The purpose of this article is to demonstrate our fixed orthopedic and orthodontic approach called "Modified Straight Wire" or "Physiologic Arch Technique." This technique is very successful with our patients because it can exert slow and continuous forces with minimal patient cooperation.

  13. Vibrating wire for beam profile scanning

    Directory of Open Access Journals (Sweden)

    S. G. Arutunian

    1999-12-01

    Full Text Available A method that measures the transverse profile (emittance of the bunch by detecting radiation arising at the scattering of the bunch on scanning wire is widely used. In this work information about bunch scattering is obtained by measuring the oscillation frequency of the tightened scanning wire. In such a way, the system of radiation (or secondary particles extraction and measurement can be removed. The entire unit consists of a compact fork with tightened wire and a scanning system. Normal oscillation frequency of a wire depends on wire tension, its geometric parameters, and, in a second approximation, its elastic characteristics. Normal oscillations are generated by interaction of an alternating current through the wire with magnetic field of a permanent magnet. In this case, it is suggested that the magnetic field of the accelerator (field of dipole magnets or quadrupole magnets be used for excitation of oscillations. The dependence of oscillation frequency on beam scattering is determined by several factors, including changes of wire tension caused by transverse force of the beam and influence of beam self-field. Preliminary calculations show that the influence of wire heating will dominate. We have studied strain gauges on the basis of vibrating wire from various materials (tungsten, beryl bronze, and niobium zirconium alloys. A scheme of normal oscillation generation by alternating current in autogeneration circuit with automatic frequency adjustment was selected. A special method of wire fixation and elimination of transverse degrees of freedom allows us to achieve relative stability better than 10^{-5} during several days at a relative resolution of 10^{-6}. Experimental results and estimates of wire heating of existing scanners show that the wire heats up to a few hundred grades, which is enough for measurements. The usage of wire of micrometer thickness diminishes the problem of wire thermalization speed during the scanning of the bunch.

  14. Pin Wire Coating Trip Report

    International Nuclear Information System (INIS)

    Spellman, G P

    2004-01-01

    A meeting to discuss the current pin wire coating problems was held at the Reynolds plant in Los Angeles on 2MAR04. The attendance list for Reynolds personnel is attached. there was an initial presentation which gave a brief history and the current status of pin wire coating at Reynolds. There was a presentation by Lori Primus on the requirements and issues for the coating. There was a presentation by Jim Smith of LANL on the chemistry and to some extent process development done to date. There was a long session covering what steps should be taken in the short term and, to a lesser extent, the long term. The coating currently being used is a blend of two polymers, polyethersulfone and polyparabanic acid (PPA) and some TiO2 filler. This system was accepted and put into production when the pin wire coating was outsourced to another company in 1974. When that company no longer was interested, the wire coating was brought in-house to Reynolds. At that time polyparabanic acid was actually a commercial product available from Exxon under the trade name Tradlon. However, it appears that the material used at Reynolds was synthesized locally. Also, it appears that a single large batch was synthesized in that time period and used up to 1997 when the supply ran out. The reason for the inclusion of TiO2 is not known although it does act as a rheological thickener. However, a more controlled thickening can be obtained with materials such as fumed silica. This material would have less likelihood of causing point imperfections in the coatings. Also, the mixing technique being used for all stages of the process is a relatively low shear ball mill process and the author recommends a high shear process such as a three roll paint mill, at least for the final mixing. Since solvent is added to the powder at Reynolds, it may be that they need to have the paint mill there

  15. Redakční systém sportovního klubu

    OpenAIRE

    Gvizd, Peter

    2015-01-01

    GVIZD, P., Redakční systém sportovního klubu. Brno, 2015. The aim of this Bachelor thesis is to create a content management systems's de-sign for the sport club Jednota Sokol Chocholná -- Velčice. The design is created on the basis of the club analysis and the identification of the key properties, which should be met by the content management system. Other properties of the content management system are deduced from the club requirements. The implementation was realized by standard technologi...

  16. Système de recommandation des services web sémantiques.

    OpenAIRE

    KARAOUZENE, Meryem

    2015-01-01

    : Les systèmes de recommandation sont capables d’estimer l’intérêt d’un utilisateur pour une ressource donnée à partir de certaines informations relatives à d’autres utilisateurs similaires et aux propriétés des ressources. Dans ce mémoire nous avons présenté les phases d’une application sur ce domaine en introduisant la notion de recommandation sociale basant sur le filtrage collaboratif pour structurer les services web sémantique, on Calculant des similarités entre items pour...

  17. Diagnostic des systèmes de culture à base de mil [ Pennisetum ...

    African Journals Online (AJOL)

    Objectif : Le présent travail a pour objectif, de faire un état des lieux des systèmes de production à base de mil en Côte d'Ivoire septentrionale afin de proposer de nouvelles pistes d'amélioration. Méthodologie et résultats : L'approche méthodologique s'est reposée sur une enquête auprès des paysans sur le terrain dans ...

  18. Alergenos: relación entre función biológica y alergenicidad

    Directory of Open Access Journals (Sweden)

    Homero San Juan

    1998-03-01

    Full Text Available Los alergenos se encuentran en muy diversas fuentes, pero, tienen la particularidad de inducir la producción de inmunoglobulina E (IgE y provocar alergia. No se conoce una característica molecular biológica común entre los alergenos que explique su capacidad alergénica. En los últimos años, se han demostrado o inferido diferentes funciones biológicas en los alergenos, generando nuevas hipótesis sobre el papel de dichas funciones en la actividad alergénica. Con el fin de identificar qué funciones biológicas se han demostrado o inferido en los alergenos y analizar su posible influencia en el papel alergénico, se revisaron aproximadamente doscientos alergenos teniendo como base los ya caracterizados por el Comité de Nomenclatura de Alergenos de la OMS, como también otros menos caracterizados pero con algunas propiedades fisicoquímicas conocidas. Los alergenos se agruparon de acuerdo con la actividad biológica y se tabularon con su fuente de origen, peso molecular (PM, punto isoeléctrico (pl, frecuencia de reactividad en la población alérgica, potenciales sitios de glicosilación y formación de enlaces disulfuro. Se identificaron 88 alergenos en los que se ha informado alguna actividad biológica. El agrupamiento de estos según la actividad produjo los siguientes resultados: enzimática (47,2%, inhibición de enzimas (11,3%, transporte (18,1%, regulación de la actividad celular (15,9% y otras actividades como la de conferir resistencia a enfermedades en plantas y citólisis (7,9%. En muchos de estos alergenos, la actividad biológica ha sido inferida por su homología estructural con proteínas de función conocida, pero los experimentos que corroboren dicha función no se han realizado. La mayoría de estos alergenos tienen en común PM

  19. Self-Catalyzed CdTe Wires

    Directory of Open Access Journals (Sweden)

    Tom Baines

    2018-04-01

    Full Text Available CdTe wires have been fabricated via a catalyst free method using the industrially scalable physical vapor deposition technique close space sublimation. Wire growth was shown to be highly dependent on surface roughness and deposition pressure, with only low roughness surfaces being capable of producing wires. Growth of wires is highly (111 oriented and is inferred to occur via a vapor-solid-solid growth mechanism, wherein a CdTe seed particle acts to template the growth. Such seed particles are visible as wire caps and have been characterized via energy dispersive X-ray analysis to establish they are single phase CdTe, hence validating the self-catalysation route. Cathodoluminescence analysis demonstrates that CdTe wires exhibited a much lower level of recombination when compared to a planar CdTe film, which is highly beneficial for semiconductor applications.

  20. Phosphorus in antique iron music wire.

    Science.gov (United States)

    Goodway, M

    1987-05-22

    Harpsichords and other wire-strung musical instruments were made with longer strings about the beginning of the 17th century. This change required stronger music wire. Although these changes coincided with the introduction of the first mass-produced steel (iron alloyed with carbon), carbon was not found in samples of antique iron harpsichord wire. The wire contained an amount of phosphorus sufficient to have impeded its conversion to steel, and may have been drawn from iron rejected for this purpose. The method used to select pig iron for wire drawing ensured the highest possible phosphorus content at a time when its presence in iron was unsuspected. Phosphorus as an alloying element has had the reputation for making steel brittle when worked cold. Nevertheless, in replicating the antique wire, it was found that lowcarbon iron that contained 0.16 percent phosphorus was easily drawn to appropriate gauges and strengths for restringing antique harpsichords.

  1. Electromagnetic Behaviour of Metallic Wire Structures

    CERN Document Server

    Chui, S T

    2013-01-01

    Despite the recent development and interest in the photonics of metallic wire structures, the relatively simple concepts and physics often remain obscured or poorly explained to those who do not specialize in the field. Electromagnetic Behaviour of Metallic Wire Structures provides a clear and coherent guide to understanding these phenomena without excessive numerical calculations.   Including both background material and detailed derivations of the various different formulae applied, Electromagnetic Behaviour of Metallic Wire Structures describes how to extend basic circuit theory relating to voltages, currents, and resistances of metallic wire networks to include situations where the currents are no longer spatially uniform along the wire. This lays a foundation for a deeper understanding of the many new phenomena observed in meta-electromagnetic materials.   Examples of applications are included to support this new approach making Electromagnetic Behaviour of Metallic Wire Structures a comprehensive and ...

  2. Electro-mechanics of drift tube wires

    International Nuclear Information System (INIS)

    Milburn, R.H.

    1997-01-01

    The position and stability of the sense wires in very long drift tubes are affected by both gravitational and electrostatic forces, as well as by the wire tension. For a tube to be used as an element of a high-resolution detector all these forces and their effects must be understood in appropriately precise detail. In addition, the quality control procedures applied during manufacture and detector installation must be adequate to ensure that the internal wire positions remain within tolerances. It may be instructive to practitioners to review the simple theory of a taut wire in the presence of anisotropic gravitational and electrostatic fields to illustrate the conditions for stability, the equilibrium wire displacement from straightness, and the effect of the fields on the mechanical vibration frequencies. These last may be used to monitor the wire configuration externally. A number of practical formulae result and these are applied to illustrative examples. (orig.)

  3. IEE wiring regulations explained and illustrated

    CERN Document Server

    Scaddan, Brian

    2013-01-01

    The IEE Wiring Regulations Explained and Illustrated, Second Edition discusses the recommendations of the IEE Regulations for the Electrical Equipment of Buildings for the safe selection or erection of wiring installations. The book emphasizes earthing, bonding, protection, and circuit design of electrical wirings. The text reviews the fundamental requirements for safety, earthing systems, the earth fault loop impedance, and supplementary bonding. The book also describes the different types of protection, such as protection against mechanical damage, overcurrent, under voltage (which prevents

  4. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  5. La co-conception en partenariat de systèmes agricoles innovants

    Directory of Open Access Journals (Sweden)

    Vall Eric

    2016-01-01

    Full Text Available La co-conception de systèmes agricoles innovants est une piste prometteuse pour répondre au défi de l’innovation, notamment pour les exploitations agricoles familiales africaines confrontées à de multiples changements. Mais il faut penser à la place et aux rôles tenus par de multiples acteurs (agriculteurs, conseillers, chercheurs pour produire les changements souhaités par toutes les parties, et donc réfléchir à la question du partenariat dans le processus. Cet article présente la démarche de conception en partenariat de systèmes agricoles innovants (CPSAI élaborée entre 2005 et 2015 dans l’ouest du Burkina Faso, notamment sur la gestion de la fumure organique des cultures. La CPSAI s’appuie sur un dispositif partenarial formalisé et sur une démarche progressive en trois phases itératives : (1 exploration et formalisation du partenariat, (2 conceptions et test des options de changement, (3 bilan et désengagement. Les résultats obtenus montrent que l’innovation est plus efficace et durable quand elle est le produit d’un travail partenarial.

  6. Aplikace pro nositelnou elektroniku se systémem Apple WatchOS

    OpenAIRE

    Singh, Kevin

    2017-01-01

    Bakalářská práce „Aplikace pro nositelnou elektroniku se systémem Apple WatchOS“ se zabývá teoretickým rozborem komunikací M2M (Machine-to-Machine), H2H (Human- to-Human), D2D (Device-to-Device) a nositelnou elektronikou. V teoretické části jsou dále popsány chytré hodinky Apple Watch, jenž obsahují požadovaný systém WatchOS. V rámci bakalářské práce vznikly dvě aplikace, přičemž první byla vytvořena pro mobilní zařízení iPhone a druhá pro chytré hodinky Apple watch. Aplikace zobrazují inform...

  7. Posouzení stability kotevního systému

    OpenAIRE

    Krško, Matúš

    2012-01-01

    Bakalárska práca je zameraná na problematiku stability kotevného systému. Teoretická časť sa zaoberá rozdelením a technológiou výstavby kotvených stien a poruchovými stavmi, ktoré môžu nastať. Ďalej sú predstavené metódy na posúdenie vnútornej stability systému. Vo výpočtovej časti sú tieto metódy aplikované na vzorový príklad. V závere práce sú získané výsledky vyhodnotené. Bachelor´s thesis is focused on stability of anchored system. Theoretical part deals with various types of anchored ...

  8. Minimisation of the wire position uncertainties of the new CERN vacuum wire scanner

    CERN Document Server

    AUTHOR|(CDS)2069346; Barjau Condomines, A

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new fast wire scanner is foreseen to measure small emittance beams throughout the LHC injector chain, which demands a wire travelling speed up to 20 ms-1 and position measurement accuracy of the order of a few microns. The vibrations of the mechanical parts of the system, and particularly the vibrations of the thin carbon wire, were identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations is a high priority for the design and operation of the new device. This document presents the work performed to understand the main causes of the wire vibrations observed in one of the existing wire scanner and the new proposed design.

  9. Flavonoides em Annonaceae: ocorrência e propriedades biológicas

    Directory of Open Access Journals (Sweden)

    Clara dos Reis Nunes

    2012-05-01

    Full Text Available Esta revisão descreve algumas propriedades biológicas e químicas, bem como os usos etnobotânicos e farmacológicos de algumas substâncias isoladas a partir do gênero Annona (família Annonaceae. As espécies dessa família possuem distribuição tropical e subtropical. A Annona muricata L., em especial, possui proeminência na economia de frutos tropicais, além de ser quimicamente caracterizada pela presença de substâncias fenólicas e terpênicas. Logo, este trabalho destaca a importância e ocorrência desses metabólitos, bem como suas atividades biológicas.

  10. Hot wire radicals and reactions

    International Nuclear Information System (INIS)

    Zheng Wengang; Gallagher, Alan

    2006-01-01

    Threshold ionization mass spectroscopy is used to measure radical (and stable gas) densities at the substrate of a tungsten hot wire (HW) reactor. We report measurements of the silane reaction probability on the HW and the probability of Si and H release from the HW. We describe a model for the atomic H release, based on the H 2 dissociation model. We note major variations in silicon-release, with dependence on prior silane exposure. Measured radical densities versus silane pressure yield silicon-silane and H-silane reaction rate coefficients, and the dominant radical fluxes to the substrate

  11. DETECTORS: Vienna - beyond the wire

    International Nuclear Information System (INIS)

    Krammer, Manfred; Regler, Meinhard

    1995-01-01

    In 1986, at the fourth Vienna Wire Chamber Conference, Georges Charpak, the inventor of the multiwire proportional chamber, had confidently announced ''Les funérailles des chambres à fils''. Was this the writing on the wall for the conference series as well as this type of detector technology? The demand for detector innovation, coupled with imaginative thinking on the part of the organizers, have kept the Vienna venue at the forefront of the physics calendar. An additional boost to the success of the series was certainly the Nobel Prize awarded to Georges Charpak in 1992. While the major topic naturally is still wire chambers, alternative technologies are also covered. However in fields like calorimetry or ring imaging Cherenkovs, a sample of only a few prominent detectors were presented, giving some participants the impression of a biased selection. The fact that silicon detectors, electronics and track reconstruction strategies were, with the exception of the invited talks, restricted to poster presentations led to the same conclusion. As a result the organizing committee saw that it will have to revise its brief for the next conference. The conference opened with philosophical thoughts by Nobel Prizewinner Georges Charpak. The first day at Vienna is traditionally devoted to applications of gaseous detectors outside high energy physics. L. Shektman gave an overview of wire chambers for medical imaging. Further applications in medicine and in other fields like biology and space science were described by subsequent speakers. The exciting idea of flying a spectrometer on a balloon to study the fraction of electrons and positrons in cosmic rays attracted a lot of attention. The next day covered wire chambers in general. V. Polychronakos presented applications of cathode strip chambers in muon spectrometers for experiments at CERN's LHC proton-proton detector. Certainly the challenges of LHC for detector development dominated many

  12. Wire alignment system for ATF LINAC

    International Nuclear Information System (INIS)

    Hayano, H.; Takeda, S.; Matsumoto, H.; Matsui, T.

    1994-01-01

    A wire based alignment system is adopted to make less than 40μm precision alignment for injector linac of Accelerator Test Facility (ATF). The system consists of two stretched SUS wires, pickup coils and active mover stages. The position of pickup coils in a mount which will be installed into LINAC stages is set to the calculated wire position prior to installation. All of LINAC stages are then moved to keep the calculated position by the active mover. The test results of wire position detection in a long term are described. (author)

  13. Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose:The Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL) provides a variety of research, design engineering and prototype fabrication services...

  14. Nickel contaminated titanium weld wire study

    International Nuclear Information System (INIS)

    Coffin, G.R.; Sumstine, R.L.

    1979-01-01

    Attachment of thermocouples to fuel rod welding problems at Exxon Nuclear Company and INEL prompted an investigation study of the titanium filler wire material. It was found that the titanium filler wire was contaminated with nickel which was jacketed on the wire prior to the drawing process at the manufacturers. A method was developed to 100% inspect all filler wire for future welding application. This method not only indicates the presence of nickel contamination but indicates quantity of contamination. The process is capable of high speed inspection necessary for various high speed manufacturing processes

  15. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  16. Manejo biológico de nematodos fitoparásitos con hongos y bacterias

    Directory of Open Access Journals (Sweden)

    Ricardo Piedra Naranjo

    2013-05-01

    Full Text Available La agricultura actual demanda la reducción de plaguicidas químicos y la introducción de sistemas sostenibles con el uso de agentes de manejo biológico.  La alternativa de usar hongos y bacterias para el manejo de nematodos fitoparásitos puede ser una opción biológica muy importante de actualidad. El manejo biológico de nematodos fitoparásitos es posible si se logra fomentar e investigar la utilización de hongos y bacterias que pueden estar en el suelo o, de lo contrario, reproducirse en laboratorios para uso comercial. En revisión de literatura se encontró varios organismos (hongos y bacterias que pueden ser utilizados por agricultores, y en algunos casos, ya están siendo aplicados. Entre los organismos encontrados, tenemos las bacterias Pasteuria penetrans, Pseudomonas (Burlkoldelia cepacia tipo Wisconsin.  Algunos hongos como: Verticillium chlamydosporium. Arthtrobotrys y Monacrosporium, Catenaria spp, Drechmeria coniospora, Pleurotus ostreatus, Pleurotus spp. Fusarium solani, Cylindrocarpon cylindroides y Paecilomyces lilacinus, Verticillium lecanii, Arthrobotrys conoides, A. musiformis, A.  robusta, Monoacrosporium ellipsosporum, Dactylaria thaumasia, Cylindrocarpon sp., Trichoderma harzianum, Dactylella brochophaga, Arthrobotrys oligospora y Arthrobotrys botryospora y Myrothecium verrucaria. Con este tipo de información, planteada desde el punto de vista en investigaciones agropecuarias, se podría tener posibilidades de utilizar nematicidas biológicos en el manejo de nematodos fitoparásitos, desarrollando un manejo integrado de plagas, donde se tendría la posibilidad de no usar de nematicidas químicos en un futuro, o por lo menos reducir sustancialmente su uso en nuestra agricultura y así mejorar la relación con el medio ambiente y el ser humano.

  17. Tratamiento de aguas industriales mediante reactor biológico de membranas

    OpenAIRE

    Aznar Jiménez, Antonio

    2008-01-01

    El Laboratorio de Ingeniería para el Tratamiento de Aguas de la Universidad Carlos III de Madrid, de investigación y servicios en el tratamiento de aguas residuales, optimiza el diseño y puesta a punto de reactores biológicos de membranas (MBR), indicados para obtener agua depurada de alta calidad y/o aumentar la capacidad de tratamiento.

  18. Medidas de bioseguridad adoptadas en el manejo con materiales biológicos en Laboratorios Liorad

    Directory of Open Access Journals (Sweden)

    Nancy Burguet Lago

    2013-03-01

    Full Text Available Introducción: el trabajo con microorganismos puede conllevar a riesgos tanto para el personal que trabaja con los mismos como para el medio ambiente. La existencia de laboratorios de seguridad biológica y la implementación de medidas en la manipulación de los agentes biológicos minimizan el riesgo. Objetivo: evaluar las medidas de bioseguridad adoptadas en el manejo con materiales biológicos en Laboratorios Liorad. Métodos: empleo de una lista de chequeo y análisis de los resultados a través de una Matriz DAFO para valorar si el diseño de la instalación cumple con la bioseguridad. Además establecer un sistema documental para la manipulación de microorganismos y la confección de un plan de capacitación para el personal que trabaja en el laboratorio de control microbiológico. Resultados: la lista de chequeo permitió identificar como principal debilidad el no disponer de un doble pasillo para el traslado del material limpio y sucio. Como fortalezas, cumplir con las prácticas y procesamientos adecuados y el contar con equipos de seguridad biológica. El sistema documental incorporó a los procedimientos establecidos para la manipulación, un acápite referido a la «Peligrosidad y Medidas de Seguridad». El programa de capacitación desarrollado permitió proveer conocimientos específicos referidos a esta temática. Conclusión: las medidas adoptadas en el laboratorio permiten plantear que de manera general se cumplen los requisitos establecidos en materia de Bioseguridad para el trabajo con microorganismos.

  19. Pozice RM-Systému na českém kapitálovém trhu

    OpenAIRE

    Novotný, Josef

    2007-01-01

    Práce popisuje historický vývoj RM-Systému, okolnosti, za kterých byl založen,princip jeho fungování. Popisuje také trhy cenných papírů z teoretického hlediska, jejich dělení a systémy, na kterých fungují. Dále práce popisuje současnou pozici RM-Systému na českém trhu cenných papírů a zkoumá její možné příčiny.

  20. Možnosti vstřikovacího systému common-rail

    OpenAIRE

    Smilek, Tomáš

    2008-01-01

    Tomáš Smilek Možnosti vstřikovacího systému common-rail BP, Ústav automobilního a dopravního inženýrství, 2008, str. 23, obr. 18, přílohy 0 Bakalářská práce se zabývá vstřikovacím systémem common-rail. Popisuje historii vývoje stejně jako jednotlivé části systému a jejich funkci. Také stanovuje výhody oproti starým způsobům vstřikování. Tomáš Smilek Possibilities of Common-rail Injection System BT, Institute of Automotive Engineering, 2008, p. 23, fig. 18, appendices 0 This study´s motivat...

  1. Medición de Activos Biológicos en Marcos Conceptuales Comparados

    Directory of Open Access Journals (Sweden)

    Beatriz Brozzú

    2008-12-01

    Full Text Available En este ensayo, no solamente pretendemos seguir probando que las NCP FAPCE (Argentina son la consecuencia de un criterio absolutamente normativista y por lo tanto restrictivo y limitado, mientras que las NIIF y las FASB se fundamentan en un paradigma basado en la “utilidad para el decisor”, o sea en las necesidades del usuario de la información. Lo que también concluiremos es que esta esencial diferencia es la causa por la cual el amplio criterio aplicado por la NIIF 41 –Activos biológicos– y la armoniosa coherencia con su Marco Conceptual, le permiten al Sistema de Información Contable lograr su principal objetivo, cual es mostrar “valor real” para todos los Activos. Por el contrario, y para que las NCP FACPCE argentinas puedan ser realmente un sistema de información útil, y en el caso especifico de la RT22 FAPCE –Activos biológicos–, ésta debe apartarse de su Marco conceptual para poder valuar los Activos Biológicos destinados a ser utilizados en el proceso productivo a un valor corriente (considerado razonablemente representativo de su valor real puesto que de respetar el Marco Conceptual debería valuarlos a valor histórico.

  2. The Influence of biol in the crop yield of Lactuca sativa L. variety Iceberg

    Directory of Open Access Journals (Sweden)

    Pomboza-Tamaquiza Pablo

    2016-11-01

    Full Text Available The objective of the research was to assess the influence of biol enriched with efficient micro-organisms, in the ecological cultivation of Lactuca sativa L (lettuce variety "Iceberg". The field test was carried out on the farm of Querochaca, Faculty of Sciences Agriculture, of the Technical University of Ambato. The studied factors were doses of biol (2%, 4% and 6% and frequencies of application (8 and 15 days, I know used the experimental design of complete blocks at random, with factorial arrangement of 3x2 1 with three repetitions. We evaluated: plant height, diameter of the main stem, days to harvest, weight and diameter of the bud commercial, performance in kg/plot neta and performance in kg/experimental unit, conducted the significance test of Duncan to 5%. The results showed that the dose of 6 per cent applied every 15 days treatment D3F2, contributed to the larger diameter of the bud commercial (25.9 cm; the greater weight of cogollo commercial (1.14 kg and the higher performance (549 kg/experimental unit. This suggests that the implementation of biol can be an important ecological alternative to fertilize organic farming as the lettuce by reducing the use of fertilizers in chemical synthesis and production costs.

  3. Atividade biológica de Davilla kunthii A. St. –Hil. (Dilleniaceae

    Directory of Open Access Journals (Sweden)

    L.S.N. NASCIMENTO

    2016-03-01

    Full Text Available RESUMO Davilla kunthii A. St. –Hil. (Dilleniaceae tem ampla distribuição vegetal. Sua família agrega uma quantidade significativa de novas substâncias, bem como importantes atividades biológicas. O uso mais comum é na medicina alternativa para combater algumas doenças, mas estudos comprovam diferentes atividades biológicas de interesse farmacológico. A literatura sobre a bioatividade de D. kunthii é incipiente. Por esta razão, os objetivos deste trabalho se concentraram em verificar os efeitos biológicos do extrato das folhas de D. kunthii, através de bioensaios frente a microrganismos patógenos Escherichia coli, Salmonella tiphymurium (bactérias gram-negativa, Staphylococcus aureus e Streptococcus sanguinis (bactérias gram-positiva, ao fungo tipo levedura Candida albicans e aos fungos filamentosos Aspergillus flavus e Fusarium proliferatum. A pesquisa verificou ainda a atividade redutora da enzima de acetilcolinesterase, e, também, foi observada a atividade antioxidante via DPPH (2,2-difenil-1-picril-hidrazila e de toxicidade frente ao microcrustáceo A. salina. Os resultados apontaram significativas atividades antioxidante, antimicrobiano, atingindo até 90% de inibição sobre a levedura C. albicans em todas as concentrações.

  4. FE modeling of Cu wire bond process and reliability

    NARCIS (Netherlands)

    Yuan, C.A.; Weltevreden, E.R.; Akker, P. van den; Kregting, R.; Vreugd, J. de; Zhang, G.Q.

    2011-01-01

    Copper based wire bonding technology is widely accepted by electronic packaging industry due to the world-wide cost reduction actions (compared to gold wire bond). However, the mechanical characterization of copper wire differs from the gold wire; hence the new wire bond process setting and new bond

  5. THERMO-MECHANICALLY PROCESSED ROLLED WIRE FOR HIGH-STRENGTH ON-BOARD WIRE

    Directory of Open Access Journals (Sweden)

    V. A. Lutsenko

    2011-01-01

    Full Text Available It is shown that at twisting of wire of diameter 1,83 mm, produced by direct wire drawing of thermomechanically processed rolled wire of diameter 5,5 mm of steel 90, metal stratification is completely eliminated at decrease of carbon, manganese and an additional alloying of chrome.

  6. Spin correlations in quantum wires

    Science.gov (United States)

    Sun, Chen; Pokrovsky, Valery L.

    2015-04-01

    We consider theoretically spin correlations in a one-dimensional quantum wire with Rashba-Dresselhaus spin-orbit interaction (RDI). The correlations of noninteracting electrons display electron spin resonance at a frequency proportional to the RDI coupling. Interacting electrons, upon varying the direction of the external magnetic field, transit from the state of Luttinger liquid (LL) to the spin-density wave (SDW) state. We show that the two-time total-spin correlations of these states are significantly different. In the LL, the projection of total spin to the direction of the RDI-induced field is conserved and the corresponding correlator is equal to zero. The correlators of two components perpendicular to the RDI field display a sharp electron-spin resonance driven by the RDI-induced intrinsic field. In contrast, in the SDW state, the longitudinal projection of spin dominates, whereas the transverse components are suppressed. This prediction indicates a simple way for an experimental diagnostic of the SDW in a quantum wire. We point out that the Luttinger model does not respect the spin conservation since it assumes the infinite Fermi sea. We propose a proper cutoff to correct this failure.

  7. Bird on a (live) wire

    Energy Technology Data Exchange (ETDEWEB)

    Farr, M.

    2003-09-30

    Bird mortality as a result of contact with power lines is discussed. U. S. statistics are cited, according to which 174 million birds annually die as a result of contact with power lines, specifically when birds touch two phases of current at the same time. Raptors are particularly vulnerable to power-line electrocution due to their habit of perching on the highest vantage point available as they survey the ground for prey. Hydro lines located in agricultural areas, with bodies of water on one side and fields on the other, also obstruct flight of waterfowl as dusk and dawn when visibility is low. Various solutions designed to minimize the danger to birds are discussed. Among these are: changing the configuration of wires and cross arms to make them more visible to birds in flight and less tempting as perches, and adding simple wire markers such as flags, balloons, and coloured luminescent clips that flap and twirl in the wind. There is no evidence of any coordinated effort to deal with this problem in Ontario. However, a report is being prepared for submission to Environment Canada outlining risks to birds associated with the growing number of wind turbine power generators (negligible compared with power lines and communications towers), and offering suggestions on remedial measures. The Fatal Light Awareness Program (FLAP) also plans to lobby the Canadian Wildlife Service to discuss the possibility of coordinating efforts to monitor, educate about and ultimately reduce this form of bird mortality.

  8. Fluorescent silver nanoparticles via exploding wire technique

    Indian Academy of Sciences (India)

    Pure silver nanoparticles in double distilled water were generated via simple physical method using pure (99.9%) silver wires with 0.2 mm diameter. These wires have been exploded in water by bringing them into sudden contact with pure (99.9%) silver plate when subjected to a potential difference of 36 V DC. High current.

  9. WIRED magazine announces rave awards nominees

    CERN Document Server

    2002-01-01

    WIRED Magazine has anounced the nominees for its fourth annual WIRED Rave Awards, celebrating innovation and the individuals transforming commerce and culture. Jeffrey Hangst of the University of Aarhus has been nominated in the science category, for his work on the ATHENA Experiment, CERN (1/2 page).

  10. 75 FR 4584 - Wire Decking From China

    Science.gov (United States)

    2010-01-28

    ... Decking From China AGENCY: United States International Trade Commission. ACTION: Scheduling of the final... subsidized and less-than-fair-value imports from China of wire decking, provided for in subheadings 9403.90... China of wire decking, and that such [[Page 4585

  11. Lansce Wire Scanning Diagnostics Device Mechanical Design

    International Nuclear Information System (INIS)

    Rodriguez Esparza, Sergio; Batygin, Yuri K.; Gilpatrick, John D.; Gruchalla, Michael E.; Maestas, Alfred J.; Pillai, Chandra; Raybun, Joseph L.; Sattler, F.D.; Sedillo, James Daniel; Smith, Brian G.

    2011-01-01

    The Accelerator Operations and Technology Division at Los Alamos National Laboratory operates a linear particle accelerator which utilizes 110 wire scanning diagnostics devices to gain position and intensity information of the proton beam. In the upcoming LANSCE improvements, 51 of these wire scanners are to be replaced with a new design, up-to-date technology and off-the-shelf components. This document outlines the requirements for the mechanical design of the LANSCE wire scanner and presents the recently developed linac wire scanner prototype. Additionally, this document presents the design modifications that have been implemented into the fabrication and assembly of this first linac wire scanner prototype. Also, this document will present the design for the second, third, and fourth wire scanner prototypes being developed. Prototypes 2 and 3 belong to a different section of the particle accelerator and therefore have slightly different design specifications. Prototype 4 is a modification of a previously used wire scanner in our facility. Lastly, the paper concludes with a plan for future work on the wire scanner development.

  12. Lansce Wire Scanning Diagnostics Device Mechanical Design

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Esparza, Sergio [Los Alamos National Laboratory; Batygin, Yuri K. [Los Alamos National Laboratory; Gilpatrick, John D. [Los Alamos National Laboratory; Gruchalla, Michael E. [Los Alamos National Laboratory; Maestas, Alfred J. [Los Alamos National Laboratory; Pillai, Chandra [Los Alamos National Laboratory; Raybun, Joseph L. [Los Alamos National Laboratory; Sattler, F. D. [Los Alamos National Laboratory; Sedillo, James Daniel [Los Alamos National Laboratory; Smith, Brian G. [Los Alamos National Laboratory

    2011-01-01

    The Accelerator Operations & Technology Division at Los Alamos National Laboratory operates a linear particle accelerator which utilizes 110 wire scanning diagnostics devices to gain position and intensity information of the proton beam. In the upcoming LANSCE improvements, 51 of these wire scanners are to be replaced with a new design, up-to-date technology and off-the-shelf components. This document outlines the requirements for the mechanical design of the LANSCE wire scanner and presents the recently developed linac wire scanner prototype. Additionally, this document presents the design modifications that have been implemented into the fabrication and assembly of this first linac wire scanner prototype. Also, this document will present the design for the second, third, and fourth wire scanner prototypes being developed. Prototypes 2 and 3 belong to a different section of the particle accelerator and therefore have slightly different design specifications. Prototype 4 is a modification of a previously used wire scanner in our facility. Lastly, the paper concludes with a plan for future work on the wire scanner development.

  13. Pretinning Nickel-Plated Wire Shields

    Science.gov (United States)

    Igawa, J. A.

    1985-01-01

    Nickel-plated copper shielding for wires pretinned for subsequent soldering with help of activated rosin flux. Shield cut at point 0.25 to 0.375 in. (6 to 10 mm) from cut end of outer jacket. Loosened end of shield straightened and pulled toward cut end. Insulation of inner wires kept intact during pretinning.

  14. Steer-by-wire innovations and demonstrator

    NARCIS (Netherlands)

    Lupker, H.A.; Zuurbier, J.; Verschuren, R.M.A.F.; Jansen, S.T.H.; Willemsen, D.M.C.

    2002-01-01

    Arguments for 'by-wire' systems include production costs, packaging and traffic safety. Innovations concern both product and development process e.g. combined virtual engineering and Hardware-in-the-loop testing. Three Steer-by-wire systems are discussed: a steering system simulator used as a

  15. Flywheel system using wire-wound rotor

    Science.gov (United States)

    Chiao, Edward Young; Bender, Donald Arthur; Means, Andrew E.; Snyder, Philip K.

    2016-06-07

    A flywheel is described having a rotor constructed of wire wound onto a central form. The wire is prestressed, thus mitigating stresses that occur during operation. In another aspect, the flywheel incorporates a low-loss motor using electrically non-conducting permanent magnets.

  16. Wire compensation: Performance, SPS MDs, pulsed system

    CERN Document Server

    Dorda, U

    2008-01-01

    A wire compensation (BBLR) scheme has been proposed in order to improve the long range beam-beam performance of the nominal LHC and its phase 1 and phase 2 upgrades[1]. In this paper we present experimental experience of the CERN SPS wires (BBLR) and report on progress with the RF BBLR.

  17. Method of preparing composite superconducting wire

    International Nuclear Information System (INIS)

    Verhoeven, J. D.; Finnemore, D. K.; Gibson, E. D.; Ostenson, J. E.; Schmidt, F. A.

    1985-01-01

    An improved method of preparing composite multifilament superconducting wire of Nb 3 Sn in a copper matrix which eliminates the necessity of coating the drawn wire with tin. A generalized cylindrical billet of an alloy of copper containing at least 15 weight percent niobium, present in the copper as discrete, randomly distributed and oriented dendritic-shaped particles, is provided with at least one longitudinal opening which is filled with tin to form a composite drawing rod. The drawing rod is then drawn to form a ductile composite multifilament wire containing a filament of tin. The ductile wire containing the tin can then be wound into magnet coils or other devices before heating to diffuse the tin through the wire to react with the niobium forming Nb 3 Sn. Also described is an improved method for making large billets of the copper-niobium alloy by consumable-arc casting

  18. Wiring Damage Analyses for STS OV-103

    Science.gov (United States)

    Thomas, Walter, III

    2006-01-01

    This study investigated the Shuttle Program s belief that Space Transportation System (STS) wiring damage occurrences are random, that is, a constant occurrence rate. Using Problem Reporting and Corrective Action (PRACA)-derived data for STS Space Shuttle OV-103, wiring damage was observed to increase over the vehicle s life. Causal factors could include wiring physical deterioration, maintenance and inspection induced damage, and inspection process changes resulting in more damage events being reported. Induced damage effects cannot be resolved with existent data. Growth analysis (using Crow-AMSAA, or CA) resolved maintenance/inspection effects (e.g., heightened awareness) on all wire damages and indicated an overall increase since Challenger Return-to-Flight (RTF). An increasing failure or occurrence rate per flight cycle was seen for each wire damage mode; these (individual) rates were not affected by inspection process effects, within statistical error.

  19. Test en ligne des systèmes à base de microprocesseur

    OpenAIRE

    Michel , Thierry

    1993-01-01

    Cette thèse traite de la vérification en ligne, par des moyens matériels, du flot de contrôle d'un système a base de microprocesseur. Une technique de compaction est utilisée pour faciliter cette vérification (analyse de signature). La plupart des méthodes proposées jusqu'ici imposent une modification du programme d'application, afin d'introduire dans celui-ci des propriétés invariantes (la signature en chaque point de l'organigramme est indépendante des chemins préalablement parcourus). Les ...

  20. Simulation of rice yield under different irrigation and nitrogen application managements by CropSyst model

    Directory of Open Access Journals (Sweden)

    Narjes ZARE

    2015-12-01

    Full Text Available The aim of this study was the calibration and validation of CropSyst model for rice in the city of Rasht. The necessary data were extracted from a field experiment which was carried out during 2005-2007 in a split-plot design. The main plots were irrigation regimes including continuous flooding irrigation and 5-day irrigation intervals. The subplots consisted of four nitrogen levels: zero N application, 45, 60 and 75 kg N ha-1. Normalized Root Mean Squared Error (nRMSE and Residual Mass Coefficient (Crm in calibration years were 9.3 % and 0.06, respectively. In validation year, nRMSE and Crm were 9.7 % and 0.11, respectively. According to other indices to assess irrigation regimes and fertilizer levels, the most suitable treatments regarding environmental aspect were 5-day irrigation regime and 45 kg N ha-1.

  1. Automatizace chyb objednávkového systému

    OpenAIRE

    Bažant, Milan

    2007-01-01

    Bakalářská práce se zabývá vytvořením softwaru pro automatizaci oprav integračních chyb objednávkového systému. Na základě analýzy chyb, jejich příčin a možnostech opravy zajistit automatizaci opravy tak, aby nebyl potřeba ruční zásah a nedocházelo ke zpoždění realizace objednávek zákazníků. The bachelor thesis focuses on the creation of the automatic error cleansing software which clears the errors generated by the ordering system. Based on the error analysis (e.g. their causes and possib...

  2. Systèmes de type radar appliqués aux domaines routiers et ferroviaires

    OpenAIRE

    DELOOF, P; GHYS, JP; RIVENQ, A; HAESE, N; SAINT-VENANT, M

    2001-01-01

    La détection d'obstacles par radar peut s'appliquer aussi bien au domaine des transports routiers qu'à ceux des transports en commun. Quelques uns de ces systèmes sont étudiés au LEOST dans le cadre du GRRT, Groupement Régional Nord Pas-de-Calais pour la Recherche dans les Transports. La plupart des capteurs micro-ondes furent réalisés par le DHS. Ils étaient fondés soit sur la modulation linéaire en fréquence (FMCW) soit sur la modulation par impulsions. Ces études ont mené à la réalisation ...

  3. Wiring of electronic evaluation circuits

    International Nuclear Information System (INIS)

    Bauer, R.; Svoboda, Z.

    1977-01-01

    The wiring is described of electronic evaluation circuits for the automatic viewing of photographic paper strip negatives on which line tracks with an angular scatter relative to the spectrograph longitudinal axis were recorded during the oblique flight of nuclear particles during exposure in the spectrograph. In coincidence evaluation, the size of the angular scatter eventually requires that evaluation dead time be increased. The equipment consists of minimally two fixed registers and a block of logic circuits whose output is designed such as will allow connection to equipment for recording signals corresponding to the number of tracks on the film. The connection may be implemented using integrated circuits guaranteeing high operating reliability and life. (J.B.)

  4. Single wire drift chamber design

    International Nuclear Information System (INIS)

    Krider, J.

    1987-01-01

    This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 μm rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles

  5. Systèmes d'information sur la santé Transposer les données ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    28 mars 2013 ... Au pire, un système d'information sur la santé dysfonctionnel peut entraîner la non-satisfaction des besoins fondamentaux de la population. Briser le ... Five IDRC-supported health systems researchers talk about how their work is improving primary health care for mothers and children, and changin.

  6. PLC SCADA systém pro řízení větrného tunelu

    OpenAIRE

    Trenčan, Tomáš

    2017-01-01

    Předložená bakalářská práce se věnuje programovatelnému automatu (PLC) firmy WAGO a SCADA systémům. Skládá se ze dvou části, z teoretické části a z praktické části. V teoretické části jsou na zakladě poznatků z odborné literatury vymezeny pojmy ohledně SCADA systémů, PLC od firmy WAGO a vývojového prostředí e!COCKPIT firmy WAGO a rešerše volně dostupných SCADA systémů podporujících Modbus TCP. Na základě této rešerše byl vybrán SCADA systém pro vizualizaci dvou demonstračníc úloh v praktické ...

  7. Riesgo biológico y prácticas de bioseguridad en docencia

    Directory of Open Access Journals (Sweden)

    Alejandra M. Diaz-Tamayo

    2016-02-01

    Full Text Available Resumen Los riesgos ocupacionales a los cuales están expuestos los docentes del área de salud, aumentan con el desempeño de sus actividades asistenciales y prácticas formativas con estudiantes, por esto durante su formación profesional se exigen conocimientos, juicio crítico, desarrollo de habilidades y destrezas en el cumplimiento de sus funciones. Objetivo: evaluar el conocimiento en riesgo biológico y el cumplimiento de las prácticas de bioseguridad en el personal docente, responsable de la formación clínica de los estudiantes de los programas académicos de la Facultad de Salud de una Institución de Educación Superior. Metodología: estudio descriptivo, de corte transversal, con una muestra de 78 docentes, entrevistados personalmente y en sus áreas de trabajo. Se evaluaron variables de conocimiento respecto al concepto que tienen los docentes sobre riesgo biológico y bioseguridad y la variable de prácticas respecto al cumplimiento de normas de bioseguridad. Resultados: la tercera parte de los docentes evaluados conocen sobre riesgo biológico y bioseguridad y en un porcentaje menor se evidenció la aplicación de prácticas de bioseguridad. No se observaron relaciones estadísticamente significativas entre conocimiento en riesgo biológico y bioseguridad y tipo de vinculación y antigüedad docente. Discusión: los docentes reconocen la exposición al riesgo biológico, pero preocupa la baja utilización de medidas de bioseguridad y de procedimientos recomendados para prevenir accidentes. Conclusiones: se espera que los docentes del área de la salud tengan un alto conocimiento sobre riesgo biológico y aplicación de normas de bioseguridad, pero esta investigación demostró las deficiencias en este tema por la población estudiada. Abstract Professors working in the field of health are exposed to occupational risks that increase as they perform their care and teaching activities with students. Thus their professional

  8. Biolingüística y capacidad humana Biolinguistics and Human Capacity

    Directory of Open Access Journals (Sweden)

    Chomsky Noam Abraham

    2006-06-01

    Full Text Available Este artículo presenta de manera sucinta el enfoque llamado 'biolingüístico' que empezó a desarrollarse en los primeros años de la posguerra, teniendo en cuenta los avances de la biología y las matemáticas. Se pasa revista a algunos postulados de la neurociencia (i.e. ciencia cognitiva en lo concerniente a la 'facultad del lenguaje', así como a los dos últimos modelos de la GG: el modelo de 'Principios y Parámetros' (P&P y el modelo 'Minimalista'. Estos últimos buscan responder las cuestiones fundamentales de la biología del lenguaje, su naturaleza, uso y evolución. Desde este punto de vista, se trata de caracterizar el equipamiento biológico gracias al cual los seres humanos adquieren una gramática. Así las cosas, se considera el equipamiento biológico como una función que asocia experiencia y gramática.This paper depicts a brief account of the so-called ´biolinguistic´ approach which dates back to the first postwar years, by taking into account progress in biology and mathematics. Some postulates of neuroscience (i.e. cognitive science regarding the ´faculty of language´ as well as the last two models of GG: the ´Principles and Parameters´ (P&P and the ´Minimalist´ models are reviewed. The latter aim to provide answers to key questions on the biology of language, its nature, its use, and its evolution. From this standpoint it has been attempted to characterize the biological endowment which allows human beings to acquire a grammar. Thus the biological endowment is seen as a function relating experience to grammar.

  9. LANSCE wire scanning diagnostics device mechanical design

    International Nuclear Information System (INIS)

    Rodriguez Esparza, Sergio

    2010-01-01

    The Los Alamos Neutron Science Center (LANSCE) is one of the major experimental science facilities at the Los Alamos National Laboratory (LANL). The core of LANSCE's work lies in the operation of a powerful linear accelerator, which accelerates protons up to 84% the speed oflight. These protons are used for a variety of purposes, including materials testing, weapons research and isotopes production. To assist in guiding the proton beam, a series of over one hundred wire scanners are used to measure the beam profile at various locations along the half-mile length of the particle accelerator. A wire scanner is an electro-mechanical device that moves a set of wires through a particle beam and measures the secondary emissions from the resulting beam-wire interaction to obtain beam intensity information. When supplemented with data from a position sensor, this information is used to determine the cross-sectional profile of the beam. This measurement allows beam operators to adjust parameters such as acceleration, beam steering, and focus to ensure that the beam reaches its destination as effectively as possible. Some of the current wire scanners are nearly forty years old and are becoming obsolete. The problem with current wire scanners comes in the difficulty of maintenance and reliability. The designs of these wire scanners vary making it difficult to keep spare parts that would work on all designs. Also many of the components are custom built or out-dated technology and are no longer in production.

  10. LANSCE wire scanning diagnostics device mechanical design

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Esparza, Sergio [Los Alamos National Laboratory

    2010-01-01

    The Los Alamos Neutron Science Center (LANSCE) is one of the major experimental science facilities at the Los Alamos National Laboratory (LANL). The core of LANSCE's work lies in the operation of a powerful linear accelerator, which accelerates protons up to 84% the speed oflight. These protons are used for a variety of purposes, including materials testing, weapons research and isotopes production. To assist in guiding the proton beam, a series of over one hundred wire scanners are used to measure the beam profile at various locations along the half-mile length of the particle accelerator. A wire scanner is an electro-mechanical device that moves a set of wires through a particle beam and measures the secondary emissions from the resulting beam-wire interaction to obtain beam intensity information. When supplemented with data from a position sensor, this information is used to determine the cross-sectional profile of the beam. This measurement allows beam operators to adjust parameters such as acceleration, beam steering, and focus to ensure that the beam reaches its destination as effectively as possible. Some of the current wire scanners are nearly forty years old and are becoming obsolete. The problem with current wire scanners comes in the difficulty of maintenance and reliability. The designs of these wire scanners vary making it difficult to keep spare parts that would work on all designs. Also many of the components are custom built or out-dated technology and are no longer in production.

  11. Aspectos biológicos de Microcharops anticarsiae (Hymenoptera: Ichneumonidae) parasitando Anticarsia gemmatalis (Lepidoptera: Erebidae)

    OpenAIRE

    Aguirre-Gil, Oniel Jeremías [UNESP

    2016-01-01

    Microcharops anticarsiae é um eficiente parasitoide da lagarta-dasoja Anticarsia gemmatalis que, também, parasita lagartas de outras espécies como Chrysodeixis includens e Spodoptera eridania. O objetivo do trabalho foi (1) determinar o ínstar larval de A. gemmatalis preferencialmente parasitado por M. anticarsiae a partir de lagartas coletadas em campo, (2) determinar o efeito de criações sucessivas de M. anticarsiae nos parâmetros biológicos do parasitoide e (3) determinar o efeito da soja ...

  12. Heterocronía, generadora de cambios biológicos

    OpenAIRE

    Picasso, Mariana

    2007-01-01

    El reloj biológico se ha acelerado o retrasado reiteradas veces a lo largo de la historia de los seres vivos. De este modo, se han modificado tanto los tiempos del desarrollo general del cuerpo, como de una estructura en particular, e incluso el tiempo en el que se produce la maduración sexual del organismo. Estos cambios temporales se denominan eventos de heterocronía (del griego, heteros: distinto, chronos: tiempo) y son una piedra angular del proceso evolutivo. Las heterocronías son respon...

  13. Observación de muestras biológicas al microscopio óptico

    OpenAIRE

    Alvarez Hornos, Francisco Javier; Izquierdo Sanchis, Marta

    2013-01-01

    La observación microscópica de muestras de aguas de los reactores biológicos de una Estación Depuradora de Aguas Residuales proporciona información cualitativa sobre la calidad de la población microbiana y del estado de los flóculos. En este vídeo, se muestra la utilización de un microscopio óptico para la observación de muestras de agua de un reactor de fangos activados. Data: 2013 ;

  14. Substrats biològics de la conducta agressiva: Genètica i Neuroanatomia

    OpenAIRE

    Martí Carbonell, Sunsi

    1984-01-01

    En este trabajo se exponen los resultados obtenidos por un gran número de investigadores que han intentado explicar cómo intervienen los diferentes substratos biológicos en la agresión. Nos hemos centrado aquí en los substratos genético y neuroanatómico, y en un trabajo posteirior expondremos los substratos neuroquímico y hormonal. This paper is a review of the works dailing with the biological substrate of aggression with special referece to genetic and neuroanatomical findings. In a next...

  15. Las ciencias biológicas en el arte argentino contemporáneo

    OpenAIRE

    Matewecki, Natalia

    2008-01-01

    En este trabajo se describen las obras más recientes del arte argentino ligado a la ciencia y a la tecnología. Desde las producciones desarrolladas en el marco de la vida artificial que incluyen algoritmos evolutivos, algoritmos genéticos, autómatas celulares y robóticos, hasta los proyectos de bioarte que comprenden el uso de la biotecnología, todas estas obras marcan la pauta de un siglo caracterizado por el despliegue de las ciencias biológicas.

  16. Actividad biológica de los aceites esenciales de Acmella ciliata (Kunth) Cass

    OpenAIRE

    Rincón Mejía, Carlos Andrés; Castaño Osorio, Jhon Carlos; Ríos Vázquez, Eunice

    2012-01-01

    Introducción: Acmella ciliata (Kunth) Cass. es una arvense nativa del norte de Suramérica conocida por su contenido de alcamidas alifáticas, se usa popularmente como anestésico y analgésico contra los dolores de muelas y de garganta. Objetivos: obtener, analizar y evaluar la actividad biológica de los aceites esenciales de las flores y hojas de Acmella ciliata (Kunth) Cass. Métodos: se obtuvieron los aceites esenciales de Acmella ciliata por hidrodestilación e hidrodestilación asistida por mi...

  17. Materiales de vaciado aglutinados con carbonato cálcico de origen biológico

    OpenAIRE

    Abelló Ulloa, Sol

    2002-01-01

    La tesis que se presenta tiene por objeto la obtención de copias que reproduzcan fielmente, obras originales compuestas de carbonato cálcico (ya sea piedra, piezas arqueológicas, pintura mural, etc., así como piezas resultantes de la actividad de distintos organismos vivos, como conchas, marfiles, huesos, etc.), mediante el vaciado de materiales aglutinados con carbonado cálcico de origen biológico. En un principio, este proyecto de investigación se basaba únicamente en la obtención de copias...

  18. Maduración biológica y aptitudes cognitivas

    OpenAIRE

    Asensio Aguilera, Josep M.

    1987-01-01

    El avance experimentado por algunas disciplinas biológicas en los ultimos años ha permitido comprender mejor ciertas características de los procesos de desarrollo del cerebro que revelan un claro interés pedagógico. De los datos proporcionados por la Neurobiología y la Cronobiología se desprende la apreciable influencia que ejerce el ambiente en la composición y estructura del neocórtex, al igual que la existencia de un ritmo de desarrollo cerebral variable, segun los sujetos, dentro de las p...

  19. Wire-rope emplacement of diagnostics systems

    International Nuclear Information System (INIS)

    Burden, W.L.

    1982-01-01

    The study reported here was initiated to determine if, with the Cable Downhole System (CDS) currently under development, there is an advantage to using continuous wire rope to lower the emplacement package to the bottom of the hole. A baseline design using two wire ropes as well as several alternatives are discussed in this report. It was concluded that the advantages of the wire-rope emplacement system do not justify the cost of converting to such a system, especially for LLNL's maximum emplacement package weights

  20. Welding wires for high-tensile steels

    International Nuclear Information System (INIS)

    Laz'ko, V.E.; Starova, L.L.; Koval'chuk, V.G.; Maksimovich, T.L.; Labzina, I.E.; Yadrov, V.M.

    1993-01-01

    Strength of welded joints in arc welding of high-tensile steels of mean and high thickness by welding wires is equal to approximately 1300 MPa in thermohardened state and approximately 600 MPa without heat treatment. Sv-15Kh2NMTsRA-VI (EhK44-VI) -Sv-30Kh2NMTsRA-VI (EkK47-VI) welding wires are suggested for welding of medium-carbon alloyed steels. These wires provide monotonous growth of ultimate strength of weld metal in 1250-1900 MPa range with increase of C content in heat-treated state

  1. Plastic deformation of 2D crumpled wires

    International Nuclear Information System (INIS)

    Gomes, M A F; Donato, C C; Brito, V P; Coelho, A S O

    2008-01-01

    When a single long piece of elastic wire is injected through channels into a confining two-dimensional cavity, a complex structure of hierarchical loops is formed. In the limit of maximum packing density, these structures are described by several scaling laws. In this paper this packing process is investigated but using plastic wires which give rise to completely irreversible structures of different morphology. In particular, the plastic deformation from circular to oblate configurations of crumpled wires is experimentally studied, obtained by the application of an axial strain. Among other things, it is shown that in spite of plasticity, irreversibility and very large deformations, scaling is still observed.

  2. Fast wire scanner for intense electron beams

    Directory of Open Access Journals (Sweden)

    T. Moore

    2014-02-01

    Full Text Available We have developed a cost-effective, fast rotating wire scanner for use in accelerators where high beam currents would otherwise melt even carbon wires. This new design uses a simple planetary gear setup to rotate a carbon wire, fixed at one end, through the beam at speeds in excess of 20  m/s. We present results from bench tests, as well as transverse beam profile measurements taken at Cornell’s high-brightness energy recovery linac photoinjector, for beam currents up to 35 mA.

  3. Resonant tunneling of electrons in quantum wires

    International Nuclear Information System (INIS)

    Krive, I.V.; Shekhter, R.I.; Jonson, M.; Krive, I.V.

    2010-01-01

    We considered resonant electron tunneling in various nanostructures including single wall carbon nanotubes, molecular transistors and quantum wires formed in two-dimensional electron gas. The review starts with a textbook description of resonant tunneling of noninteracting electrons through a double-barrier structure. The effects of electron-electron interaction in sequential and resonant electron tunneling are studied by using Luttinger liquid model of electron transport in quantum wires. The experimental aspects of the problem (fabrication of quantum wires and transport measurements) are also considered. The influence of vibrational and electromechanical effects on resonant electron tunneling in molecular transistors is discussed.

  4. Fabrication of FFTF fuel pin wire wrap

    International Nuclear Information System (INIS)

    Epperson, E.M.

    1980-06-01

    Lateral spacing between FFTF fuel pins is required to provide a passageway for the sodium coolant to flow over each pin to remove heat generated by the fission process. This spacing is provided by wrapping each fuel pin with type 316 stainless steel wire. This wire has a 1.435mm (0.0565 in.) to 1.448mm (0.0570 in.) diameter, contains 17 +- 2% cold work and was fabricated and tested to exacting RDT Standards. About 500 kg (1100 lbs) or 39 Km (24 miles) of fuel pin wrap wire is used in each core loading. Fabrication procedures and quality assurance tests are described

  5. Problems associated with iridium-192 wire implants

    International Nuclear Information System (INIS)

    Arnott, S.J.; Law, J.; Ash, D.; Flynn, A.; Paine, C.H.; Durrant, K.R.; Barber, C.D.; Dixon-Brown, A.

    1985-01-01

    Three incidents are reported, from different radiotherapy centres, in which an implanted iridium-192 wire remained in the tissues of a patient after withdrawal of the plastic tubing in which it was contained. In each case the instrument used to cut the wire had probably formed a hook on the end of the wire which caused it to catch in the tissues. Detailed recommendations are made for avoiding such incidents in the future, the most important of which is that the patient should be effectively monitored after the supposed removal of all radioactive sources. (author)

  6. Investigation of wire motion in superconducting magnets

    International Nuclear Information System (INIS)

    Ogitsu, T.; Tsuchiya, K.; Devred, A.

    1990-09-01

    The large Lorentz forces occuring during the excitation of superconducting magnets can provoke sudden motions of wire, which eventually release enough energy to trigger a quench. These wire motions are accompanied by two electromagnetic effects: an induced emf along the moved wire, and a local change in flux caused by the minute dislocation of current. Both effects cause spikes in the coil voltage. Voltage data recorded during the excitation of a superconducting quadrupole magnet which early exhibit such events are here reported. Interpretations of the voltage spikes in terms of energy release are also presented, leading to insights on the spectrum of the disturbances which occur in real magnets. 15 refs

  7. Guerra biológica, bioterrorismo e saúde pública

    Directory of Open Access Journals (Sweden)

    Luiz Jacintho da Silva

    Full Text Available O uso de agentes biológicos como arma não é novidade para a humanidade. Durante séculos, até a atualidade, a guerra biológica tem sido objeto de muita pesquisa e especulação, mas de pouca ação. O medo de efeitos contrários e dúvidas sobre sua eficiência como armas devem ter limitado seu uso. Recentemente, se verificou uma nova forma de terrorismo, empregando agentes infecciosos, devagar e sem muito alarde, até as ocorrências recentes com o Bacillus anthracis nos Estados Unidos. A varíola é possivelmente o mais devastador desses agentes. Menos de 25 anos passados desde sua erradicação, a saúde pública tem que lidar com a possibilidade de sua re-introdução. O cenário da re-introdução da varíola no Brasil é discutido.

  8. Guerra biológica, bioterrorismo e saúde pública

    Directory of Open Access Journals (Sweden)

    Silva Luiz Jacintho da

    2001-01-01

    Full Text Available O uso de agentes biológicos como arma não é novidade para a humanidade. Durante séculos, até a atualidade, a guerra biológica tem sido objeto de muita pesquisa e especulação, mas de pouca ação. O medo de efeitos contrários e dúvidas sobre sua eficiência como armas devem ter limitado seu uso. Recentemente, se verificou uma nova forma de terrorismo, empregando agentes infecciosos, devagar e sem muito alarde, até as ocorrências recentes com o Bacillus anthracis nos Estados Unidos. A varíola é possivelmente o mais devastador desses agentes. Menos de 25 anos passados desde sua erradicação, a saúde pública tem que lidar com a possibilidade de sua re-introdução. O cenário da re-introdução da varíola no Brasil é discutido.

  9. Guerra biológica, bioterrorismo e saúde pública

    Directory of Open Access Journals (Sweden)

    Luiz Jacintho da Silva

    2001-12-01

    Full Text Available O uso de agentes biológicos como arma não é novidade para a humanidade. Durante séculos, até a atualidade, a guerra biológica tem sido objeto de muita pesquisa e especulação, mas de pouca ação. O medo de efeitos contrários e dúvidas sobre sua eficiência como armas devem ter limitado seu uso. Recentemente, se verificou uma nova forma de terrorismo, empregando agentes infecciosos, devagar e sem muito alarde, até as ocorrências recentes com o Bacillus anthracis nos Estados Unidos. A varíola é possivelmente o mais devastador desses agentes. Menos de 25 anos passados desde sua erradicação, a saúde pública tem que lidar com a possibilidade de sua re-introdução. O cenário da re-introdução da varíola no Brasil é discutido.

  10. Wire Bonder: Kulicke and Soffa Model 4526

    Data.gov (United States)

    Federal Laboratory Consortium — Description:CORAL Name: Wire BonderNeeds Description.Scientific Opportunities / Applications:Wedge bonderSemi-automatic and manual modesIndependent Z-axis control,...

  11. t matrix of metallic wire structures

    International Nuclear Information System (INIS)

    Zhan, T. R.; Chui, S. T.

    2014-01-01

    To study the electromagnetic resonance and scattering properties of complex structures of which metallic wire structures are constituents within multiple scattering theory, the t matrix of individual structures is needed. We have recently developed a rigorous and numerically efficient equivalent circuit theory in which retardation effects are taken into account for metallic wire structures. Here, we show how the t matrix can be calculated analytically within this theory. We illustrate our method with the example of split ring resonators. The density of states and cross sections for scattering and absorption are calculated, which are shown to be remarkably enhanced at resonant frequencies. The t matrix serves as the basic building block to evaluate the interaction of wire structures within the framework of multiple scattering theory. This will open the door to efficient design and optimization of assembly of wire structures

  12. Diamond wire cutting of heat exchangers

    International Nuclear Information System (INIS)

    Beckman, T.R.; Bjerler, J.

    1991-01-01

    With the change-out of equipment at nuclear power plants comes large quantities of low level contaminated metallic waste. Of particular concern are large heat exchangers, preheaters and steam generators. These bulky items consume huge volumes of burial space. The need for volume reduction and recycling of these metals has created new demands for 'how' to cut heat exchangers into useful sizes for decontamination, melting or compaction. This paper reviews the cutting solution provided by a diamond wire system, with particular regard for cutting of a Ringhals Preheater Bundle at Studsvik Nuclear in 1989. The background of diamond wire sawing is discussed and basic components of wire sawing are explained. Other examples of wire cutting decommissioned components are also given. (author)

  13. Copyright and Wire Broadcasting Under Belgian Law

    Science.gov (United States)

    Namurois, Albert

    1975-01-01

    A discussion of a case whereby substantial damages, if not criminal proceedings, will sanction, according to circumstances, both television organizations and those who in certain conditions distribute their programs by wire or communicate them to the public. (Author/HB)

  14. Temperature Dependent Wire Delay Estimation in Floorplanning

    DEFF Research Database (Denmark)

    Winther, Andreas Thor; Liu, Wei; Nannarelli, Alberto

    2011-01-01

    Due to large variations in temperature in VLSI circuits and the linear relationship between metal resistance and temperature, the delay through wires of the same length can be different. Traditional thermal aware floorplanning algorithms use wirelength to estimate delay and routability. In this w......Due to large variations in temperature in VLSI circuits and the linear relationship between metal resistance and temperature, the delay through wires of the same length can be different. Traditional thermal aware floorplanning algorithms use wirelength to estimate delay and routability....... In this work, we show that using wirelength as the evaluation metric does not always produce a floorplan with the shortest delay. We propose a temperature dependent wire delay estimation method for thermal aware floorplanning algorithms, which takes into account the thermal effect on wire delay. The experiment...

  15. Angular response of hot wire probes

    International Nuclear Information System (INIS)

    Di Mare, L; Jelly, T O; Day, I J

    2017-01-01

    A new equation for the convective heat loss from the sensor of a hot-wire probe is derived which accounts for both the potential and the viscous parts of the flow past the prongs. The convective heat loss from the sensor is related to the far-field velocity by an expression containing a term representing the potential flow around the prongs, and a term representing their viscous effect. This latter term is absent in the response equations available in the literature but is essential in representing some features of the observed response of miniature hot-wire probes. The response equation contains only four parameters but it can reproduce, with great accuracy, the behaviour of commonly used single-wire probes. The response equation simplifies the calibration the angular response of rotated slanted hot-wire probes: only standard King’s law parameters and a Reynolds-dependent drag coefficient need to be determined. (paper)

  16. Josephson junction arrays and superconducting wire networks

    International Nuclear Information System (INIS)

    Lobb, C.J.

    1992-01-01

    Techniques used to fabricate integrated circuits make it possible to construct superconducting networks containing as many as 10 6 wires or Josephson junctions. Such networks undergo phase transitions from resistive high-temperature states to ordered low-resistance low-temperature states. The nature of the phase transition depends strongly on controllable parameters such as the strength of the superconductivity in each wire or junction and the external magnetic field. This paper will review the physics of these phase transitions, starting with the simplest zero-magnetic field case. This leads to a Kosterlitz-Thouless transition when the junctions or wires are weak, and a simple mean-field fransition when the junctions or wires are strong. Rich behavior, resulting from frustration, occurs in the presence of a magnetic field. (orig.)

  17. 47 CFR 32.2321 - Customer premises wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Customer premises wiring. 32.2321 Section 32... Customer premises wiring. (a) This account shall include all amounts transferred from the former Account 232, Station Connections, inside wiring subclass. (b) Embedded Customer Premises Wiring is that...

  18. 29 CFR 1926.404 - Wiring design and protection.

    Science.gov (United States)

    2010-07-01

    .... Receptacles on a two-wire, single-phase portable or vehicle-mounted generator rated not more than 5kW, where the circuit conductors of the generator are insulated from the generator frame and all other grounded... wiring shall be grounded: (i) Three-wire DC systems. All 3-wire DC systems shall have their neutral...

  19. Automatic reel controls filler wire in welding machines

    Science.gov (United States)

    Millett, A. V.

    1966-01-01

    Automatic reel on automatic welding equipment takes up slack in the reel-fed filler wire when welding operation is terminated. The reel maintains constant, adjustable tension on the wire during the welding operation and rewinds the wire from the wire feed unit when the welding is completed.

  20. Modelling aluminium wire bond reliability in high power OMP devices

    NARCIS (Netherlands)

    Kregting, R.; Yuan, C.A.; Xiao, A.; Bruijn, F. de

    2011-01-01

    In a RF power application such as the OMP, the wires are subjected to high current (because of the high power) and high temperature (because of the heat from IC and joule-heating from the wire itself). Moreover, the wire shape is essential to the RF performance. Hence, the aluminium wire is

  1. Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires.

    Science.gov (United States)

    Tada, Yoshifumi; Hayakawa, Tohru; Nakamura, Yoshiki

    2017-08-09

    Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 × 0.022 in² and 0.019 × 0.025 in² (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bending properties were evaluated in a modified three-point bending system for orthodontics. The static friction between the orthodontic wire and the bracket was also measured. The load-deflection curves were similar among Ni-Ti and PEEK wires, except for 16PEEK with slot-lid ligation. The bending force of 19-25PEEK wire was comparable with that of Ni-Ti wire. 19-25PEEK showed the highest load at the deflection of 1500 μm ( p 0.05). No significant difference was seen in static friction between all three PEEK wires and Ni-Ti wire ( p > 0.05). It is suggested that 19-25PEEK will be applicable for orthodontic treatment with the use of slot-lid ligation.

  2. Audio wiring guide how to wire the most popular audio and video connectors

    CERN Document Server

    Hechtman, John

    2012-01-01

    Whether you're a pro or an amateur, a musician or into multimedia, you can't afford to guess about audio wiring. The Audio Wiring Guide is a comprehensive, easy-to-use guide that explains exactly what you need to know. No matter the size of your wiring project or installation, this handy tool provides you with the essential information you need and the techniques to use it. Using The Audio Wiring Guide is like having an expert at your side. By following the clear, step-by-step directions, you can do professional-level work at a fraction of the cost.

  3. Tracking with wire chambers at the SSC

    International Nuclear Information System (INIS)

    Hanson, G.G.; Gundy, M.C.; Palounek, A.P.T.

    1989-07-01

    Limitations placed on wire chambers by radiation damage and rate requirements in the SSC environment are reviewed. Possible conceptual designs for wire chamber tacking systems that meet these requirements are discussed. Computer simulation studies of tracking in such systems are presented. Simulations of events from interesting physics at the SSC, including hits from minimum bias background events, are examined. Results of some preliminary pattern recognition studies are given. 13 refs., 11 fig., 1 tab

  4. Charge Transport Along Phenylenevinylene Molecular Wires

    OpenAIRE

    2006-01-01

    Abstract A model to calculate the mobility of charges along molecular wires is presented. The model is based on the tight-binding approximation and combines a quantum mechanical description of the charge with a classical description of the structural degrees of freedom. It is demonstrated that the average mobility of charge carriers along molecular wires can be obtained by time-propagation of states which are initially localised. The model is used to calculate the mobility of charg...

  5. A Magnetic Sensor with Amorphous Wire

    Directory of Open Access Journals (Sweden)

    Dongfeng He

    2014-06-01

    Full Text Available Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  6. Deformable wire array: fiber drawn tunable metamaterials

    DEFF Research Database (Denmark)

    Fleming, Simon; Stefani, Alessio; Tang, Xiaoli

    2017-01-01

    By fiber drawing we fabricate a wire array metamaterial, the structure of which can be actively modified. The plasma frequency can be tuned by 50% by compressing the metamaterial; recovers when released and the process can be repeated.......By fiber drawing we fabricate a wire array metamaterial, the structure of which can be actively modified. The plasma frequency can be tuned by 50% by compressing the metamaterial; recovers when released and the process can be repeated....

  7. Tracking with wire chambers at high luminosities

    International Nuclear Information System (INIS)

    Hanson, G.G.

    1989-12-01

    Radiation damage and rate limitations impose severe constraints on wire chambers at the SSC. Possible conceptual designs for wire chamber tracking systems that satisfy these constraints are discussed. Computer simulation studies of tracking in such systems are presented. Simulations of events from interesting physics at the SSC, including hits from minimum bias background events, are examined. Results of some preliminary pattern recognition studies are given. 11 refs., 10 figs

  8. COBRA-IV wire wrap data comparisons

    International Nuclear Information System (INIS)

    Donovan, T.E.; George, T.L.; Wheeler, C.L.

    1979-02-01

    Thermal hydraulic analyses of hexagonally packed wire-wrapped fuel assemblies are complicated by the induced crossflow between adjacent subchannels. The COBRA-IV computer code simultaneously solves the hydrodynamics and thermodynamics of fuel assemblies. The modifications and the results are presented which are predicted by the COBRA-IV calculation. Comparisons are made with data measured in five experimental models of a wire-wrapped fuel assembly

  9. Novel use of the "buddy"wire.

    LENUS (Irish Health Repository)

    O'Hare, A

    2008-12-29

    Summary: During interventional procedures the tortuosity of the vasculature hampers catheter stability. The buddy wire may be used to aid and maintain vascular access.We describe a case of acute subarachnoid haemorrhage secondary to dissecting aneurysm of the vertebral artery.We discuss the value of the buddy wire during balloon occlusion of the vertebral artery not as it is typically used, but to actually prevent the balloon repeatedly entering the posterior inferior cerebellar artery during the procedure.

  10. Le système de l'harmonie de Rameau dans sa correspondance avec d'Alembert et Rousseau

    Directory of Open Access Journals (Sweden)

    Stefanović Ana M.

    2002-01-01

    Full Text Available (francuski L'article examine la correspondance polémique de Rameau avec d'Alembert et Rousseau, entretenue dans la sixième décénie du XVIIIe siècle. Le système de l'harmonie de Rameau y est affronté à deux défis contradictoires: d'un côté, à la provocation d'absolutisation du système venant de son intériorité-même, et de l'autre, à une nouvelle conception de l'autonomie musicale, conçue sur le geste anarchique et destructif envers lui. Tandis que, de la polémique avec d'Alembert, le système vient de ressortir assuré et renforcé, soutenant la suprématie de la musique dans le champ théorique, la polémique avec Rousseau démontre que l'autonomie scientifique n'entraîne pas de soi l'isolation de la musique dans le domaine esthétique. Fondé sur le réseau cohérent de ses propres règles, le système musical est apte de se plier, de se modifier sous l'influence de ce qui lui est "extérieur": du sens contenu dans des énoncés linguistiques. L'idée de représentation musicale est alors modifiée dans la direction d'une réconcilliation possible de la raison (cartésienne et de l'imagination créatrice, du général et du particulier, de la norme et de l'individualité, dans la mesure où le système musical devenant analogue au système linguistique, en tant que "langue en action" participe chaque fois dans l'événement de sa propre création.

  11. Induced Voltage in an Open Wire

    Science.gov (United States)

    Morawetz, K.; Gilbert, M.; Trupp, A.

    2017-07-01

    A puzzle arising from Faraday's law has been considered and solved concerning the question which voltage will be induced in an open wire with a time-varying homogeneous magnetic field. In contrast to closed wires where the voltage is determined by the time variance of the magnetic field and the enclosed area, in an open wire we have to integrate the electric field along the wire. It is found that the longitudinal electric field with respect to the wave vector contributes with 1/3 and the transverse field with 2/3 to the induced voltage. In order to find the electric fields the sources of the magnetic fields are necessary to know. The representation of a spatially homogeneous and time-varying magnetic field implies unavoidably a certain symmetry point or symmetry line which depend on the geometry of the source. As a consequence the induced voltage of an open wire is found to be the area covered with respect to this symmetry line or point perpendicular to the magnetic field. This in turn allows to find the symmetry points of a magnetic field source by measuring the voltage of an open wire placed with different angles in the magnetic field. We present exactly solvable models of the Maxwell equations for a symmetry point and for a symmetry line, respectively. The results are applicable to open circuit problems like corrosion and for astrophysical applications.

  12. Superconducting wires and methods of making thereof

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xingchen; Sumption, Michael D.; Peng, Xuan

    2018-03-13

    Disclosed herein are superconducting wires. The superconducting wires can comprise a metallic matrix and at least one continuous subelement embedded in the matrix. Each subelement can comprise a non-superconducting core, a superconducting layer coaxially disposed around the non-superconducting core, and a barrier layer coaxially disposed around the superconducting layer. The superconducting layer can comprise a plurality of Nb.sub.3Sn grains stabilized by metal oxide particulates disposed therein. The Nb.sub.3Sn grains can have an average grain size of from 5 nm to 90 nm (for example, from 15 nm to 30 nm). The superconducting wire can have a high-field critical current density (J.sub.c) of at least 5,000 A/mm.sup.2 at a temperature of 4.2 K in a magnetic field of 12 T. Also described are superconducting wire precursors that can be heat treated to prepare superconducting wires, as well as methods of making superconducting wires.

  13. Impedance Characterisation of the SPS Wire Scanner

    CERN Document Server

    AUTHOR|(CDS)2091911; Prof. Sillanpää, Mika

    As a beam diagnostic tool, the SPS wire scanner interacts with the proton bunches traversing the vacuum pipes of the Super Proton Synchrotron particle accelerator. Following the interaction, the bunches decelerate or experience momentum kicks off-axis and couple energy to the cavity walls, resonances and to the diagnostic tool, the scanning wire. The beam coupling impedance and, in particular, the beam induced heating of the wire motivate the characterisation and redesign of the SPS wire scanner. In this thesis, we characterise RF-wise the low frequency modes of the SPS wire scanner. These have the highest contribution to the impedance. We measure the cavity modes in terms of resonance frequency and quality factor by traditional measurement techniques and data analysis. We carry out a 4-port measurement to evaluate the beam coupling to the scanning wire, that yields the spectral heating power. If combined with the simulations, one is able to extract the beam coupling impedance and deduce the spectral dissipa...

  14. Chemistry of radiation damage to wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1992-08-01

    Proportional counters are used to study aspects of radiation damage to wire chambers (wire aging). Principles of low-pressure, rf plasma chemistry are used to predict the plasma chemistry in electron avalanches (1 atm, dc). (1) Aging is studied in CF 4 /iC 4 H 10 gas mixtures. Wire deposits are analyzed by Auger electron spectroscopy. An apparent cathode aging process resulting in loss of gain rather than in a self-sustained current is observed in CF 4 -rich gases. A four-part model considering plasma polymerization of the hydrocarbon, etching of wire deposits by CF 4 , acceleration of deposition processes in strongly etching environments, and reactivity of the wire surface is developed to understand anode wire aging in CF 4 /iC 4 H 10 gases. Practical guidelines suggested by the model are discussed. (2) Data are presented to suggest that trace amounts of Freons do not affect aging rates in either dimethyl ether or Ar/C 2 H 6 . Apparent loss of gain is explained by attachment of primary electrons to a continuously increasing concentration of Freon 11 (CCl 3 F) in the counter gas. An increase in the concentration of Freon 11 in dimethyl ether is caused by a distillation process in the gas supply bottle and is a natural consequence of the unequal volatilities of the two compounds

  15. Si Wire-Array Solar Cells

    Science.gov (United States)

    Boettcher, Shannon

    2010-03-01

    Micron-scale Si wire arrays are three-dimensional photovoltaic absorbers that enable orthogonalization of light absorption and carrier collection and hence allow for the utilization of relatively impure Si in efficient solar cell designs. The wire arrays are grown by a vapor-liquid-solid-catalyzed process on a crystalline (111) Si wafer lithographically patterned with an array of metal catalyst particles. Following growth, such arrays can be embedded in polymethyldisiloxane (PDMS) and then peeled from the template growth substrate. The result is an unusual photovoltaic material: a flexible, bendable, wafer-thickness crystalline Si absorber. In this paper I will describe: 1. the growth of high-quality Si wires with controllable doping and the evaluation of their photovoltaic energy-conversion performance using a test electrolyte that forms a rectifying conformal semiconductor-liquid contact 2. the observation of enhanced absorption in wire arrays exceeding the conventional light trapping limits for planar Si cells of equivalent material thickness and 3. single-wire and large-area solid-state Si wire-array solar cell results obtained to date with directions for future cell designs based on optical and device physics. In collaboration with Michael Kelzenberg, Morgan Putnam, Joshua Spurgeon, Daniel Turner-Evans, Emily Warren, Nathan Lewis, and Harry Atwater, California Institute of Technology.

  16. 75 FR 60480 - In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire...

    Science.gov (United States)

    2010-09-30

    ... Welding Wire Containers and Components Thereof and Welding Wire; Notice of Commission Determination To... within the United States after importation of certain bulk welding wire containers, components thereof, and welding wire by reason of infringement of certain claims of United States Patent Nos. 6,260,781; 6...

  17. Empolder and application of LiveWire program

    International Nuclear Information System (INIS)

    Zhang Bo; Li Jing; Wang Xiaoming

    2007-01-01

    LiveWire is a specific module of Netscape Web server to actualize CGI function; through LiveWire application program one can create dynamic web page on web site. This article introduces how to write LiveWire application code, have to compile, debug and manage LiveWire application programs, and how to apply LiveWire application program on Netscape Web server to create a dynamic web page. (authors)

  18. Supplemental Analysis Survey of C&P Telephone Inside Wiring.

    Science.gov (United States)

    1986-10-01

    telephone company facilities in 1984. In 1985, among other actions favorable to deregulation and detariffing of inside wiring, the FCC proposed to detariff ...installation of inside wiring, detariff the maintenance of all inside wiring, treat all inside wiring as customer premise equipment and pass ownership...85-148, 50 Fed. let. 13991 (April 9, 1985), pToposing to detariff the installation of simple inside wiring and also to detariff the maintenance of all

  19. The Analysis of the High Speed Wire Drawing Process of High Carbon Steel Wires Under Hydrodynamic Lubrication Conditions

    Directory of Open Access Journals (Sweden)

    Suliga M.

    2015-04-01

    Full Text Available In this work the analysis of the wire drawing process in hydrodynamic dies has been done. The drawing process of φ5.5 mm wire rod to the final wire of φ1.7 mm was conducted in 12 passes, in drawing speed range of 5-25 m/s. For final wires of φ1.7 mm the investigation of topography of wire surface, the amount of lubricant on the wire surface and the pressure of lubricant in hydrodynamic dies were determined. Additionally, in the work selected mechanical properties of the wires have been estimated.

  20. Les touristes dans le système touristique polynésien: essai de typologie

    Directory of Open Access Journals (Sweden)

    Caroline Blondy

    2012-03-01

    Full Text Available Les touristes sont couramment considérés, dans la plupart des analyses, comme une catégorie homogène et distincte de la catégorie «société locale». L’un des enjeux de la thèse a été de déconstruire cette idée. Partant d’une définition du tourisme comme «système d’acteurs, de pratiques et de lieux qui a pour objectif de permettre aux individus de se déplacer pour leur recréation hors de leur lieu de vie habituel, en allant habiter temporairement d’autres lieux.» (Dehoorne et al., 2003, l’analyse de la catégorie des touristes amène à s’interroger sur leurs pratiques et leur rapport à l’altérité.

  1. Archivage électronique : spécifications relatives à la conception et à l'exploitation de systèmes informatiques en vue d'assurer la conservation et l'intégrité des documents stockés dans ces systèmes

    CERN Document Server

    Association Française de Normalisation. Paris

    2007-01-01

    Archivage électronique : spécifications relatives à la conception et à l'exploitation de systèmes informatiques en vue d'assurer la conservation et l'intégrité des documents stockés dans ces systèmes

  2. Evaluación de riesgo biológico en el Hospital Rey Don Jaime

    Directory of Open Access Journals (Sweden)

    Salomé Benavent Nácher

    2007-03-01

    Full Text Available Objetivo: El propósito del presente trabajo es realizar una evaluación del riesgo biológico existente para los trabajadores del Hospital con el fin de identificar los puestos de trabajo y microorganismos que suponen mayor riesgo y poder adoptar medidas preventivas. Métodos: Se aplicó la metodología BIOGAVAL de evaluación de riesgo biológico desarrollado por el Gabinete de Seguridad e Higiene de Valencia. Dicho método contempla una identificación de los microorganismos presentes mas probables, su posible daño a la salud, mecanismos de transmisión, porcentaje de población diana vacunado y el efecto protector de las medidas higiénicas. Se aplicó a los distintos puestos de trabajo que presentan riesgo biológico exceptuando cocina. Resultados: Los resultados evidencian un mayor riesgo para los microorganismos de transmisión aérea y con baja protección vacunal, así como un nivel de riesgo superior (comparado con otros trabajadores de los ATS/DUE de urgencias. Conclusiones: El método se ha revelado útil para evidenciar los puestos de trabajo más peligrosos así como los agentes microbiológicos de mayor riesgo. Igualmente aporta una orientación sobre la prioridad para la aplicación de medidas preventivas de control.Objective: The purpose of this work is to realize an evaluation of the existing biological risk for the staff at the hospital with the aim of both identifying the jobs and microorganisms which mean a higher risk and to be able to adopt preventive measures. Methods: It was applied the BIOGAVAL methodology of evaluation of biological risk developed by the Safety and Hygiene Office in Valencia. This method deals with an identification of the most probable present microorganisms, their possible hurt for health, transmission mechanisms, percentage of target population vaccinated and the protective effect of the hygienic measures. It was applied to the different jobs which show biological risk except for the kitchen ones

  3. Tratamiento biológico aerobio de alpechín depurado previamente con ozono

    Directory of Open Access Journals (Sweden)

    Domínguez Vargas, Joaquín R.

    2000-10-01

    Full Text Available In the present work, the degradation of olive mill wastewaters previously treated by an ozonation stage has been studied by an aerobic biological oxidation. The substrate evolution (based on chemical oxygen demand, biomass (measured as volatile suspended solids and total polyphenolic contents were followed during each experiment. A kinetic study is performed by using the Contois model, which applied to the experimental data, provides the specific kinetic parameters of this model. The deduced kinetic equation for the consume of substrate is q= 17.0 S/(18.2 X + S0 X g COD/ gVSS. day. Moreover, others interesting biological parameters like the cellular yield coefficient and the kinetic rate constant for the endogenous metabolism were determined, obtaining a values of 0.214 g VSS/g COD and 0.167 day-1, respectively.En el presente trabajo se ha estudiado la oxidación biológica aerobia por Iodos activos de las aguas residuales de almazaras (alpechín que previamente habían sido depuradas por una etapa química mediante ozono. La evolución del proceso biológico fue seguida midiendo la concentración de sustrato (en términos de demanda química de oxígeno, la concentración de biomasa (medida como sólidos en suspensión volátiles y el contenido en compuestos polifenólicos totales. Se realiza un estudio cinético basado en el modelo de Contois que, aplicado a los datos experimentales, permite calcular los parámetros cinéticos específicos de este modelo. La ecuación deducida para el consumo de sustrato es q= 17.0 S/(18.2 X + S0 X, g DQO/ gSSV. día. Al mismo tiempo se han determinado otros parámetros biológicos de interés como son el coeficiente de rendimiento celular y la constante cinética correspondiente al metabolismo endógeno, obteniéndose unos valores de 0.214 g SSV/g DQO y 0.167 día-1, respectivamente.

  4. Etude systématique et écologique de la faune associée aux moules ()

    OpenAIRE

    Fezzani, S.; Zghal, F.; Ben Amor, Z.; El Abed, A.

    2001-01-01

    Ce travail s’intéresse non seulement à la connaissance de la faune associée aux moules notamment : Mytilus galloprovincialis, mais aussi à une étude systématique et écologique de la faune récoltée. Cette étude a été réalisée dans le lac de Bizerte, à la station de mytiliculture de Menzel Jemil. Une partie de ce travail est consacrée à un examen systématique de la faune récoltée et qui nous a permis d’inventorier 6 embranchements dont les annélides qui sont représentés par 10 espèces de Po...

  5. CDMA à séquence directe appliqué aux systèmes de communications optiques

    OpenAIRE

    Lourdiane , Mounia

    2005-01-01

    Depuis quelques années, le besoin de systèmes de communications plus rapides et plus sures se fait sentir. Le partage entre utilisateurs de la très grande bande passante des fibres optiques nécessite des techniques d'accès adaptées. Afin de répondre à ces besoins, un certain nombre de techniques de multiplexage, dont le CDMA, ont été développées. Cette technique d'accès multiple est déjà largement utilisée dans les systèmes de communications radio-mobiles, que ce soit dans les normes américai...

  6. Electrodo biológico con la enzima hidrogenasa, procedimiento de obtención y sus aplicaciones

    OpenAIRE

    Fernández López, Víctor Manuel; López de Lacey, Antonio; Rüdiger Ortiz, Olaf

    2005-01-01

    Electrodo biológico con la enzima hidrogenasa, procedimiento de obtención y sus aplicaciones. En la presente invención se protegen electrodos biológicos modificados con enzimas hidrogenasas (ánodos) mediante los cuales es posible obtener energía eléctrica del hidrógeno en una configuración típica de pilas de combustible; asimismo, con estos electrodos modificados con hidrogenasa (cátodos) es posible producir hidrógeno a partir de agua en una configuración típica de cél...

  7. Investigación sobre el efecto de la temperatura en los procesos biológicos por fangos activos

    OpenAIRE

    Francisco Díaz, Juan Pablo de

    2003-01-01

    Durante la presente Investigación se ha estudiado el efecto que produce la temperatura en los procesos de depuración biológica por fangos activos, desarrollando la influencia de dicho factor en cada una de las etapas de la línea de agua de una estación depuradora. - Pretratamiento - Decantación Primaria - Reactor Biológico - Decantación Secundaria Se ha considerado que los efectos de la temperatura en los procesos meramente físicos, son mínimos, únicamente provocados por la variación de la de...

  8. Contribuições a estudos biológicos com o uso de modelos biofísicos

    OpenAIRE

    de Cássia Moura do Nascimento, Rita

    2004-01-01

    Um modelo biofísico é uma representação simplificada e/ou abstrata de processos ou sistemas biológicos. Objetivando ampliar o conhecimento sobre a modelagem biofísica, esta Tese enfoca prioritariamente os modelos que desenvolvemos, visando contribuir com os estudos biológicos. Proteínas transportadoras do tipo canal iônico encontram-se presentes na membrana plasmática de todos os seres vivos e o primeiro modelo biofísico é uma membrana plasmática artificial, na qual há um co...

  9. Control biológico de moscas blancas en cultivo de tomate: interacciones entre sus enemigos naturales

    OpenAIRE

    Moreno Ripoll, Rafael

    2011-01-01

    [spa] Para obtener un control biológico adecuado de las plagas presentes en un cultivo es importante determinar las relaciones tróficas que existen entre los enemigos naturales y su efecto sobre el control de estas plagas. Dos de estas interacciones, la depredación intragremial y el canibalismo, pueden condicionar el éxito de los programas de control biológico produciendo efectos aditivos o negativos sobre las poblaciones de la plaga. Para determinar la ingesta de todos los estados de desarro...

  10. Droits des femmes et accès à l'eau et aux systèmes d ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Partout sur la planète, les citadines pauvres doivent composer chaque jour avec les problèmes liés à l'absence de systèmes d'assainissement sûrs, abordables, accessibles et appropriées. L'ONG Women in Cities International (WICI) tente de trouver des moyens de remédier à cette situation en Inde. Cette subvention lui ...

  11. La recherche-action participative appliquée aux systèmes de santé ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    4 déc. 2014 ... Une nouvelle publication, intitulée Participatory Action Research in Health Systems: a methods reader, a été lancée à l'occasion du troisième Symposium mondial sur la recherche sur les systèmes de santé, qui s'est tenu au Cap, en Afrique du Sud, du 30 septembre au 3 octobre 2014. Ce guide des ...

  12. Solutionner les problèmes du système d'autobus urbain au Salvador ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Un trajet en autobus public au Salvador peut être une expérience périlleuse, mais un projet de recherche contribue à améliorer ce système de transport qui dessert des millions de gens. Cet article fait partie d'une série de reportages sur des projets innovants mis en œuvre dans les pays en développement, compilée dans ...

  13. Caractérisation physico-chimique d'un système lotique en région ...

    African Journals Online (AJOL)

    SARAH

    31 mai 2017 ... région tropicale : la rivière Sô au Sud-Bénin, Afrique de l'Ouest. ... la mise en place d'un plan de gestion durable de la rivière et son bassin ...... système qui contrôle et traite les eaux usées avant leur ... Étude dynamique des.

  14. Agent des systèmes d'information financière (h/f) | CRDI - Centre de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Répondre directement aux demandes des utilisateurs formulées par courriel ou par téléphone ou par l'entremise du système de gestion des appels de dépannage. Communiquer au besoin avec les fournisseurs de logiciels et le personnel responsable des TI pour régler les problèmes rencontrés par les utilisateurs finaux ...

  15. Carsim : un système pour convertir des textes en scènes tridimensionnelles animées

    NARCIS (Netherlands)

    Nugues, P.; Dupuy, S.; Egges, A.

    2004-01-01

    Cet article décrit un système de conversion de textes en scènes tridimensionnelles animées. Les textes sont des constats d’accidents de voitures rédigés par un des conducteurs. Le processus de conversion comporte de deux étapes. Un premier module d’extraction d’informations crée une description

  16. Renforcement des capacités de réaliser des examens systématiques

    International Development Research Centre (IDRC) Digital Library (Canada)

    LIRNEasia appliquera les protocoles de la Collaboration Campbell et renforcera les capacités des deux communautés précitées de réaliser des examens systémiques qui évalueront et consolideront les connaissances sur de grandes questions de développement, dont les suivantes : - l'incidence de l'argent mobile sur les ...

  17. Mountain Plains Learning Experience Guide: Electrical Wiring. Course: Electrical Wiring Rough-In.

    Science.gov (United States)

    Arneson, R.; And Others

    One of two individualized courses included in an electrical wiring curriculum, this course covers electrical installations that are generally hidden within the structure. The course is comprised of four units: (1) Outlet and Switch Boxes, (2) Wiring, (3) Service Entrance, and (4) Signal and Low Voltage Systems. Each unit begins with a Unit…

  18. Effect of discrete wires on the implosion dynamics of wire array Z pinches

    International Nuclear Information System (INIS)

    Lebedev, S. V.; Beg, F. N.; Bland, S. N.; Chittenden, J. P.; Dangor, A. E.; Haines, M. G.; Kwek, K. H.; Pikuz, S. A.; Shelkovenko, T. A.

    2001-01-01

    A phenomenological model of wire array Z-pinch implosions, based on the analysis of experimental data obtained on the mega-ampere generator for plasma implosion experiments (MAGPIE) generator [I. H. Mitchell , Rev. Sci. Instrum. 67, 1533 (1996)], is described. The data show that during the first ∼80% of the implosion the wire cores remain stationary in their initial positions, while the coronal plasma is continuously jetting from the wire cores to the array axis. This phase ends by the formation of gaps in the wire cores, which occurs due to the nonuniformity of the ablation rate along the wires. The final phase of the implosion starting at this time occurs as a rapid snowplow-like implosion of the radially distributed precursor plasma, previously injected in the interior of the array. The density distribution of the precursor plasma, being peaked on the array axis, could be a key factor providing stability of the wire array implosions operating in the regime of discrete wires. The modified ''initial'' conditions for simulations of wire array Z-pinch implosions with one-dimension (1D) and two-dimensions (2D) in the r--z plane, radiation-magnetohydrodynamic (MHD) codes, and a possible scaling to a larger drive current are discussed

  19. Modeling and simulation of the fluid flow in wire electrochemical machining with rotating tool (wire ECM)

    Science.gov (United States)

    Klocke, F.; Herrig, T.; Zeis, M.; Klink, A.

    2017-10-01

    Combining the working principle of electrochemical machining (ECM) with a universal rotating tool, like a wire, could manage lots of challenges of the classical ECM sinking process. Such a wire-ECM process could be able to machine flexible and efficient 2.5-dimensional geometries like fir tree slots in turbine discs. Nowadays, established manufacturing technologies for slotting turbine discs are broaching and wire electrical discharge machining (wire EDM). Nevertheless, high requirements on surface integrity of turbine parts need cost intensive process development and - in case of wire-EDM - trim cuts to reduce the heat affected rim zone. Due to the process specific advantages, ECM is an attractive alternative manufacturing technology and is getting more and more relevant for sinking applications within the last few years. But ECM is also opposed with high costs for process development and complex electrolyte flow devices. In the past, few studies dealt with the development of a wire ECM process to meet these challenges. However, previous concepts of wire ECM were only suitable for micro machining applications. Due to insufficient flushing concepts the application of the process for machining macro geometries failed. Therefore, this paper presents the modeling and simulation of a new flushing approach for process assessment. The suitability of a rotating structured wire electrode in combination with an axial flushing for electrodes with high aspect ratios is investigated and discussed.

  20. Bezpečnost operačního systému Apple iOS

    OpenAIRE

    Zahradníček, Zdeněk

    2013-01-01

    Bakalářská práce se zabývá zabezpečením operačního systému iOS a vytvářením aplikací pro tento systém. Popisuje základní vlastnosti systému, použitá zabezpečení, šifrování a třídy pro bezpečné ukládání souborů. Další oblastí, kterou se práce zabývá je zabezpečení přístupu k internetu a ochranou odesílaných a přijímaných dat. V práci je popsán programovací balíček Xcode, používaný vývojáři pro iOS platformu. Dále byla zkompilována aplikace pro ukázku práce s tímto programovacím balíčkem a její...

  1. Guide du calcul en mécanique valider le comportement des systèmes techniques

    CERN Document Server

    Spenlé, Daniel

    2012-01-01

    Ce guide couvre l’essentiel des programmes de la Première STI2D aux sections de BTS pour les compétences liées à la mécanique. Pour prendre en compte les nouveautés pédagogiques, cette nouvelle édition évolue vers des systèmes « grand public » (robotique humanoïde, cycle trainer, power-ball…) ou des systèmes liés au développement durable(éolienne, scooter électrique…). Points forts - Un guide qui tient compte des orientations du nouveau programme de STI2D : - systèmes vibratoires ; - accéléromètres, effet gyroscopique ; - développement de l’énergétique. - Les disciplines Génie mécanique/Génie électrique sont décloisonnées: - introduction de dispositifs pluri-techniques ; - présentation d’interfaces liant la partie opérative à la partie commande ; - introduction de la conversion de l’énergie électrique en énergie mécanique et réciproquement, étude comportementale, point de fonctionnement, définition des grandeurs associées. - Le caractère expérimental, ...

  2. Systémová dynamika a její modely jako součást Competitive Intelligence

    Directory of Open Access Journals (Sweden)

    Stanislava Mildeová

    2014-12-01

    Full Text Available Obchodní konkurence je oblast, která zatím plně nevyužívá výhod modelování a simulace. V reakci na tento fakt je cílem článku ukázat model simulující konkurenční boj. Model, vycházející z logiky Systémové dynamiky, slouží ke zkoumání efektu vývoje produktů na konkurenceschopnost podniku. V rámci tvorby tohoto vlastního modelu a provedených experimentů autor dokazuje, že použití modelování a simulací je užitečné při získávání nových informací, které nejsou obsaženy v podnikových informačních systémech. I když je prezentovaný model zjednodušením skutečného trhu, takový systémový model může být perspektivním nástrojem Competitive Intelligence.

  3. Theory of wire number scaling in wire-array Z pinches

    International Nuclear Information System (INIS)

    Desjarlais, M.P.; Marder, B.M.

    1999-01-01

    Pulsed-power-driven Z pinches, produced by imploding cylindrical arrays of many wires, have generated very high x-ray radiation powers (>200 TW) and energies (2 MJ). Experiments have revealed a steady improvement in Z-pinch performance with increasing wire number at fixed total mass and array radius. The dominant mechanism acting to limit the performance of these devices is believed to be the Rayleigh-Taylor instability which broadens the radially imploding plasma sheath and consequently reduces the peak radiation power. A model is presented which describes an amplification over the two-dimensional Rayleigh-Taylor growth rate brought about by kink-like forces on the individual wires. This amplification factor goes to zero as the number of wires approaches infinity. This model gives results which are in good agreement with the experimental data and provides a scaling for wire-array Z pinches. copyright 1999 American Institute of Physics

  4. Evolution of cementite morphology in pearlitic steel wire during wet wire drawing

    International Nuclear Information System (INIS)

    Zhang Xiaodan; Godfrey, Andrew; Hansen, Niels; Huang Xiaoxu; Liu Wei; Liu Qing

    2010-01-01

    The evolution of the cementite phase during wet wire drawing of a pearlitic steel wire has been followed as a function of strain. Particular attention has been given to a quantitative characterization of changes in the alignment and in the dimensions of the cementite phase. Scanning electron microscope observations show that cementite plates become increasingly aligned with the wire axis as the drawing strain is increased. Measurements in the transmission electron microscope show that the cementite deforms plastically during wire drawing , with the average thickness of the cementite plates decreasing from 19 nm (ε = 0) to 2 nm (ε = 3.7) in correspondence with the reduction in wire diameter. The deformation of the cementite is strongly related to plastic deformation in the ferrite, with coarse slip steps, shear bands and cracks in the cementite plates/particles observed parallel to either {110} α or {112} α slip plane traces in the ferrite.

  5. Evolution of cementite morphology in pearlitic steel wire during wet wire drawing

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2010-01-01

    The evolution of the cementite phase during wet wire drawing of a pearlitic steel wire has been followed as a function of strain. Particular attention has been given to a quantitative characterization of changes in the alignment and in the dimensions of the cementite phase. Scanning electron...... microscope observations show that cementite plates become increasingly aligned with the wire axis as the drawing strain is increased. Measurements in the transmission electron microscope show that the cementite deforms plastically during wire drawing , with the average thickness of the cementite plates...... decreasing from 19 nm (ε = 0) to 2 nm (ε = 3.7) in correspondence with the reduction in wire diameter. The deformation of the cementite is strongly related to plastic deformation in the ferrite, with coarse slip steps, shear bands and cracks in the cementite plates/particles observed parallel to either {110...

  6. Producción de un tensoactivo biológico

    Directory of Open Access Journals (Sweden)

    Rosero N. Gladys

    2002-06-01

    Full Text Available En este artículo se resume el estudio realizado en el Instituto Colombiano del Petróleo (ICP, para escalar desde el laboratorio hasta la planta piloto, un proceso para la producción de biosurfactante tipo ramnolípido. Mediante el examen de las condiciones de activación del microorganismo y del diseño del medio de cultivo se establecieron condiciones que en forma sistemática disparan el mecanismo productor del microorganismo y permiten incrementar la productividad del biosurfactante. Se demostró la alta eficiencia de este aditivo biológico en aplicaciones, tales como biodegradación de hidrocarburos en medios salinos, control de la corrosión y recuperación de crudo a partir de lodos de fondos de tanques de almacenamiento. 

  7. De la riqueza biológica a la riqueza económica

    Directory of Open Access Journals (Sweden)

    Gustavo Correa Assmus

    2011-01-01

    Full Text Available Frente al deterioro ambiental por efectos de la producción y el consumo, la economía debe ofrecer respuestas fundamentadas en procesos de investigación, educación, responsabilidad y regulación, que permitan articular el aprovechamiento de los recursos naturales renovables, administrados y no administrados, con el fin de establecer un crecimiento económico-ambiental sostenible y racionalizado que cualifique la calidad de vida. Para esta propuesta se tomó información secundaria de origen empírico, la cual permitió elaborar una teorización analítica, que expresa de manera clara sus reflexiones y conjeturas, ofreciendo un camino por seguir en el proceso de transición de la riqueza biológica a la económica.

  8. Satisfação conjugal e parentalidade biológica e adoptiva

    OpenAIRE

    Ferreira, Júlia Maria de Araújo

    2008-01-01

    Tese de mestrado, Psicologia (Psicologia Clínica e da Saúde - Núcleo de Psicologia Clínica Sistémica), 2008, Universidade de Lisboa, Faculdade de Psicologia e de Ciências da Educação O presente estudo, pretendendo uma comparação entre famílias portuguesas biológicas e adoptivas, tem como objectivo analisar a percepção de Satisfação Conjugal e a sua respectiva influência nos Estilos Parentais praticados, com o intuito de compreender a teia de relações existente entre os domínios da Conjugal...

  9. Bioseguridad y armas biológicas:\tLa amenaza de Andrómeda (1971

    Directory of Open Access Journals (Sweden)

    Manuel SÁNCHEZ

    2016-11-01

    Full Text Available La amenaza de Andrómeda es la adaptación cinematográfica de la obra homónima escrita por Michael Crichton. Puede considerarse como la película más “microbiológica” del Séptimo Arte. Dirigida por Robert Wise, este tecno-thriller describe los esfuerzos de un equipo de científicos para caracterizar y contener a un microorganismo patógeno extraterrestre. A pesar de haber sido realizada hace 40 años, se tratan temas de plena actualidad como es el de las armas biológicas, las medidas de aislamiento y protección, la automatización en los procedimientos sanitarios y la toma de decisiones ante una situación grave e inesperada.

  10. Aislamiento de microorganismos para control biológico de Moniliophthora roreri

    Directory of Open Access Journals (Sweden)

    Liliana Yanet Suárez Contreras

    2013-12-01

    Full Text Available Moniliophthora roreri es un hongo que causa la moniliasis, una enfermedad de la mazorca en el cultivo de cacao (Theobroma cacao, con pérdidas hasta del 60% de la cosecha. El control biológico utilizando microorganismos endófitos surge como una alternativa para el manejo de esta enfermedad. En la presente investigación se evaluaron microorganismos con potencial para control biológico de M. roreri en Norte de Santander, Colombia. Para el efecto, se aisló e identificó este fitopatógeno y se utilizaron protocolos de desinfección de los posibles microorganismos antagonistas con siembras por diluciones seriadas, selección de los géneros microbianos con mayor potencial antagónico y evaluación de las cepas por la prueba de plato dual para evaluar el efecto biocontrolador de los hongos y la antibiosis para bacterias. Se tomaron muestras en los municipios de Cúcuta, Sardinata, El Tarra, Tibú y El Zulia, de las cuales se aislaron 17 cepas del fitopatógeno y 20 entre hongos y bacterias. De éstas se seleccionaron cuatro cepas de hongos y tres de bacterias por su capacidad antagónica contra M. roreri. Los mejores porcentajes de inhibición de crecimiento radial (PICR se alcanzaron con Paecilomyces sp. (HC002 vs M. roreri, con una media de 80.72%, seguido del tratamiento con Paecilomyces sp. (HZ002 vs M. roreri con 79.45%. Se demostró que el hongo Paecilomyces sp. también tiene un alto potencial antagónico in vitro frente a M. roreri. Al evaluar la antibiosis de las bacterias aisladas, se encontró que Bacillus brevis (BZ005 fue la más efectiva en todos los sitios del estudio, con porcentajes superiores a 89%.

  11. Terapia biológica en enfermedades reumatológicas

    Directory of Open Access Journals (Sweden)

    Manuel F Ugarte-Gil

    2013-04-01

    Full Text Available El advenimiento del uso de terapias biológicas en Reumatología ha modificado significativamente el pronóstico de pacientes portadores de artritis reumatoide (AR, artritis juvenil (AJ, espondilitis anquilosante (EA, entre otras enfermedades. A diferencia de las terapias convencionales estos productos biológicos se dirigen a los llamados blancos terapéuticos ya sea estas una línea celular, un mediador inflamatorio o un receptor de superficie. Estos compuestos son producidos por células vivas mediante la tecnología del ADN recombinante. Estos compuestos pueden tener componentes humano y animal [quiméricos (Xi, humanizados (Zu], o completamente humanos (H lo cual se reconoce por las letras que se incluyen en el nombre de cada uno. En el campo de la Reumatología, el primer compuesto utilizado fue el etanercept (anti-factor de necrosis tumoral o anti-TNF aprobado en 1998, pero otros anti-TNF han demostrado su beneficio en AR, como en EA y AJ. Los inhibidores de Interleucina (IL-1 casi no se usan en AR actualmente, pero si los inhibidores de IL-6, así como los agentes contra las células B y los agonistas de CTLA-4 (Cytotoxic T lymphocyte antigen. Existe asimismo un compuesto dirigido al BLyS (B-lymphocyte stimulator el cual se usa en lupus eritematoso sistémico y otro dirigido al receptor activador del factor nuclear κB (RANKL, receptor activator of nuclear factor-κB ligand que se usa en osteoporosis. Con el avance en el conocimiento de la patogenia de las enfermedades reumαticas, se vienen reconociendo otra blancos terapιuticas. En los aρos venideros, este campo ha de expandirse en proporciones geomιtricas

  12. Turismo en espacios naturales: oportunidades en el corredor biológico mesoamericano

    Directory of Open Access Journals (Sweden)

    Miguel Panadero Moya

    2002-01-01

    Full Text Available El Corredor Biológico Mesoamericano es una iniciativa de los presidentes de los Estados centroamericanos para facilitar la integración subregional mediante estrategias fundamentadas en la singularidad e importancia ecológica de sus recursos naturales. Pretende implantar medidas que aseguren la conservación de estos recursos de forma compatible con el aprovechamiento socioeconómico de su potencial turístico. El territorio que lo integra se extiende por todo el istmo centroamericano y posee notables recursos naturales de alto valor ecológico y zonas de interés histórico-artístico con gran importancia cultural. Sus elementos, que se engarzan en una cadena de verdes eslabones de singular vegetación, constituyen reductos de indudable atractivo y aptitud para la práctica del turismo en la naturaleza. La incorporación a los circuitos internacionales de viajeros de este proyecto está limitada por las precarias características socioeconómicas de sus pobladores y por la debilidad de las infraestructuras y equipamientos turísticos de la mayoría de los países implicados en el proyecto. Crear un pasillo biológico en armonía con sus habitantes, en uno de los esfuerzos de conservación para el desarrollo más grande planteado hasta el momento, es la idea de sus promotores que, con esta iniciativa, se muestran participes de la lógica de la globalización.

  13. New crosslinked polyvinyl chloride insulated wire by electron beam irradiation

    International Nuclear Information System (INIS)

    Takahata, Norio; Shingyouchi, Kazuo; Sato, Masakatsu; Sasaki, Hidemi; Terunuma, Haruji

    1978-01-01

    The polyvinyl chloride-coated wires crosslinked by electron beam irradiation have made rapid progress as electric and electronic wiring material and grown to hold a firm position in this field. In response to the requirements for wires with the advance of electronic equipments, Hitachi Cable Ltd. developed a peculiar graft polymer consisting of chlorinated polyethylene and polyvinyl chloride. To this polymer, the characteristics of a very wide range from toughness to flexibility can be given, and the crosslinked polyvinyl chloride wires utilizing these characteristics were put in practical use. Many kinds of the wires were developed as follows; 105 deg. C rating crosslinked vinyl-coated wires authorized by UL and CSA standards, crosslinked vinyl-coated wires with excellent flexibility, high strength crosslinked vinyl-coated wires with thin coating and crosslinked vinyl-coated wires for automobiles. They are expected to be developed into other new fields and applications. (Kobatake, H.)

  14. Micro Wire-Drawing: Experiments And Modelling

    International Nuclear Information System (INIS)

    Berti, G. A.; Monti, M.; Bietresato, M.; D'Angelo, L.

    2007-01-01

    In the paper, the authors propose to adopt the micro wire-drawing as a key for investigating models of micro forming processes. The reasons of this choice arose in the fact that this process can be considered a quasi-stationary process where tribological conditions at the interface between the material and the die can be assumed to be constant during the whole deformation. Two different materials have been investigated: i) a low-carbon steel and, ii) a nonferrous metal (copper). The micro hardness and tensile tests performed on each drawn wire show a thin hardened layer (more evident then in macro wires) on the external surface of the wire and hardening decreases rapidly from the surface layer to the center. For the copper wire this effect is reduced and traditional material constitutive model seems to be adequate to predict experimentation. For the low-carbon steel a modified constitutive material model has been proposed and implemented in a FE code giving a better agreement with the experiments

  15. Wire scanner software and firmware issues

    International Nuclear Information System (INIS)

    Gilpatrick, John Doug

    2008-01-01

    The Los Alamos Neutron Science Center facility presently has 110 slow wire scanning profile measurement instruments located along its various beam lines. These wire scanners were developed and have been operating for at least 30 years. While the wire scanners solved many problems to operate and have served the facility well they have increasingly suffered from several problems or limitations, such as maintenance and reliability problems, antiquated components, slow data acquisition, and etc. In order to refurbish these devices, these wire scanners will be replaced with newer versions. The replacement will consist of a completely new beam line actuator, new cables, new electronics and brand new software and firmware. This note describes the functions and modes of operation that LabVIEW VI software on the real time controller and FPGA LabVIEW firmware will be required. It will be especially interesting to understand the overall architecture of these LabVIEW VIs. While this note will endeavor to describe all of the requirements and issues for the wire scanners, undoubtedly, there will be missing details that will be added as time progresses.

  16. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  17. Sensitive and simple method for measuring wire tensions

    International Nuclear Information System (INIS)

    Atac, M.; Mishina, M.

    1982-08-01

    Measuring tension of wires in drift chambers and multiwire proportional chambers after construction is an important process because sometimes wires get loose after soldering, crimping or glueing. One needs to sort out wires which have tensions below a required minimum value to prevent electrostatic instabilities. There have been several methods reported on this subject in which the wires were excited either with sinusoidal current under magnetic field or with sinusoidal voltage electrostatically coupled to the wire, searching for a resonating frequency with which the wires vibrate mechanically. Then the vibration is detected either visually, optically or with magnetic pick-up directly touching the wires. Any of these is only applicable to the usual multiwire chamber which has open access to the wire plane. They also need fairly large excitation currents to induce a detectable vibration to the wires. Here we report a very simple method that can be used for any type of wire chamber or proportional tube system for measuring wire tension. Only a very small current is required for the wire excitation to obtain a large enough signal because it detects the induced emf voltage across a wire. A sine-wave oscillator and a digital voltmeter are sufficient devices aside from a permanent magnet to provide the magnetic field around the wire. A useful application of this method to a large system is suggested

  18. 39 VetoMed : un système expert à base d'icônes pour la médecine ...

    African Journals Online (AJOL)

    PR BOKO

    Mots-clés: système expert, générateur de systèmes expert, base de connaissances, médecine traditionnelle vétérinaire, plantes médicinales, interface iconique, tradipraticien. Abstract. VetoMed : An icon-based expert system for Traditional Veterinary Medicine. In this paper we propose an expert system in which, icons are ...

  19. A new route to process diamond wires

    Directory of Open Access Journals (Sweden)

    Marcello Filgueira

    2003-06-01

    Full Text Available We propose an original route to process diamond wires, denominated In Situ Technology, whose fabrication involves mechanical conformation processes, such as rotary forging, copper tubes restacking, and thermal treatments, such as sintering and recrystallisation of a bronze 4 wt.% diamond composite. Tensile tests were performed, reaching an ultimate tensile strength (UTS of 230 MPa for the diameter of Æ = 1.84 mm. Scanning electron microscopy showed the diamond crystals distribution along the composite rope during its manufacture, as well as the diamond adhesion to the bronze matrix. Cutting tests were carried out with the processed wire, showing a probable performance 4 times higher than the diamond sawing discs, however its probable performance was about 5 to 8 times less than the conventional diamond wires (pearl system due to the low abrasion resistance of the bronze matrix, and low adhesion between the pair bronze-diamond due to the use of not metallised diamond single crystals.

  20. Longitudinal magnetic bistability of electroplated wires

    International Nuclear Information System (INIS)

    Kurlyandskaya, G.V.; Garcia-Miquel, H.; Vazquez, M.; Svalov, A.V.; Vas'kovskiy, V.O.

    2002-01-01

    Fe 20 Ni 74 Co 6 and Fe 20 Ni 64 Co 16 1 μm thick magnetic tubes electroplated onto Cu 98 Be 2 conductive wire have been investigated in as-deposited state, after heat treatment under longitudinal magnetic field for 1 h at 330 deg. C, and after rf-sputtering deposition of the additional 2 μm Fe 19 Ni 81 layer. Heat treatments and an additional layer deposition modify the shape of hysteresis loops. Magnetically bistable behaviour, observed after the field annealing at a temperature of 330 deg. C, is studied as a function of the length of the samples. This is the first report by our knowledge on the bistable behaviour of the electroplated wires. The bistability of these wires is promising for applications such as tagging or pulse generator applications

  1. Cockpit canopy shattering using exploding wire techniques

    International Nuclear Information System (INIS)

    Novac, B M; Smith, I R; Downs, P R; Marston, P; Fahey, D

    2007-01-01

    This paper presents the principal experimental results provided by a preliminary investigation into the possibility of using exploding wire (EW) techniques to shatter the plastic cockpit canopy of a modern jet aircraft. The data provided forms the basis for a qualitative understanding of the physics of interaction between the plasma produced by an EW and the surrounding elasto-plastic material in which the wire is embedded. To optimize the shock-wave 'clean cutting' effect, the significance of the material, the dimensions of the exploding wire and the amplitude of the current and voltage pulses are all considered. This leads to important conclusions concerning both the characteristics of the EW and the optimum arrangement of the electrical circuit, with the single most important optimization factor being the peak electrical power input to the EW, rather than the dissipated Joule energy. A full-scale system relevant to an actual cockpit canopy shattering is outlined and relevant results are presented and discussed

  2. Graphene wire medium: Homogenization and application

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Chigrin, Dmitry N.; Lavrinenko, Andrei

    2012-01-01

    In this contribution we analyze numerically the optical properties of the graphene wire medium, which unit cell consists of a stripe of graphene embedded into dielectric. We propose a simple method for retrieval of the isofrequency contour and effective permittivity tensor. As an example of the g......In this contribution we analyze numerically the optical properties of the graphene wire medium, which unit cell consists of a stripe of graphene embedded into dielectric. We propose a simple method for retrieval of the isofrequency contour and effective permittivity tensor. As an example...... of the graphene wire medium application we demonstrate a reconfigurable hyperlens for the terahertz subwavelength imaging capable of resolving two sources with separation λ0/5 in the far-field....

  3. Rotor Embedded with Shape Memory Alloy Wires

    Directory of Open Access Journals (Sweden)

    K. Gupta

    2000-01-01

    Full Text Available In the present analysis, the fundamental natural frequency of a Jeffcott and a two-mass rotor with fibre reinforced composite shaft embedded with shape memory alloy (SMA wires is evaluated by Rayleigh's procedure. The flexibility of rotor supports is taken into account. The effect of three factors, either singly or in combination with each other, on rotor critical speed is studied. The three factors are: (i increase in Young's modulus of SMA (NITINOL wires when activated, (ii tension in wires because of phase recovery stresses, and (iii variation of support stiffness by three times because of activation of SMA in rotor supports. It is shown by numerical examples that substantial variation in rotor critical speeds can be achieved by a combination of these factors which can be effectively used to avoid resonance during rotor coast up/down.

  4. Emulating Wired Backhaul with Wireless Network Coding

    DEFF Research Database (Denmark)

    Thomsen, Henning; De Carvalho, Elisabeth; Popovski, Petar

    2014-01-01

    In this paper we address the need for wireless network densification. We propose a solution wherein the wired backhaul employed in heterogeneous cellular networks is replaced with wireless links, while maintaining the rate requirements of the uplink and downlink traffic of each user. The first...... of the two-way protocol. The transmit power is set high enough to enable successive decoding at the small cell base station where the downlink data to the user is first decoded and its contribution removed from the received signal followed by the uplink data from the user. The decoding of the second layer......, the uplink traffic to the user, remains identical to the one performed in a wired system. In the broadcast phase, the decoding of the downlink traffic can also be guaranteed to remain identical. Hence, our solution claims an emulation of a wired backhaul with wireless network coding with same performance. We...

  5. The Fine Wire Technique for Flexor Tenolysis.

    Science.gov (United States)

    Rosenblum, Matthew K; Baltodano, Pablo A; Weinberg, Maxene H; Whipple, Lauren A; Gemmiti, Amanda L; Whipple, Richard E

    2017-11-01

    Flexor tenolysis surgery for flexor digitorum profundus and superficialis adhesions is a common procedure performed by hand surgeons. Releasing these adhered tendons can greatly improve hand function and improve quality of life. Recent evidence, however, has shown that the outcomes of tenolysis surgeries are often suboptimal and can result in relapsing adhesions or even tendon ruptures. This article describes a new technique with potential for reduced complication rates: The Fine Wire Technique for Flexor Tenolysis (FWT). Following FWT, the patient detailed in this article had an excellent recovery of function and no complications: including tendon rupture, infection, hematomas, or any other complications. She reported a major improvement from her preoperative functionality and continues to have this level of success. The wire's thinness allows for a swift tenolysis. The FWT is a new option available to the hand surgeon associated with good functional results. The wire is readily available to the clinician and is also inexpensive.

  6. Ultrasonic cleaning of electrodes of wire chambers

    International Nuclear Information System (INIS)

    Krasnov, V.A.; Kurepin, A.B.; Razin, V.I.

    1980-01-01

    A technological process of cleaning electrodes and working volume surfaces of wire chambers from contaminations by the simultaneous mechanical action of the energy of ultrasonic oscillations and the chemical action of detergents is discussed. A device for cleaning wire electrodes of proportional chambers of 0.3x0.4 m is described. The device uses two ultrasonic generators with a total power of 0.5 kW. As a detergent use is made of a mixture of ethyl alcohol, gasoline and freon. In the process of cleaning production defects can be detected in the wire chambers which makes it possible to timely remove the defects. Measurements of the surface resistance of fiberglass laminate of printed drift chamber electrodes at a voltage of 2 kV showed that after completing the cleaning process the resistance increases 15-20%

  7. A comparison of a 'J' wire and a straight wire in successful antegrade cannulation of the superficial femoral artery

    International Nuclear Information System (INIS)

    Gay, D.A.T.; Edwards, A.J.; Puckett, M.A.; Roobottom, C.A.

    2005-01-01

    AIMS: To evaluate the success of two different types of wire in common use in their ability to successfully cannulate the superficial femoral artery (SFA) using antegrade puncture. METHODS: 50 consecutive patients in whom antegrade infra-inguinal intervention was planned, underwent common femoral arterial puncture and then cannulation with either a standard 3 mm 'J' wire or a floppy tipped straight wire (William Cook--Europe). The frequency with which each type of wire entered the SFA or profunda femoris artery without image guidance was recorded. Further analysis was also made of the success of manipulation of the wire into the SFA following profunda cannulation and the use of alternative guide wires. RESULTS: In 19 out of 25 (76%) patients the 'J' wire correctly entered the SFA without image guidance. Only 5 out of 25 (25%) of straight wires entered the SFA with the initial pass (p<0.0001). Following further manipulation with the same wire all except 1 'J' wire was successfully negotiated into the SFA. The same was true for only 9 of the remaining straight wires with 11 patients requiring an alternative guide wire. CONCLUSIONS: When performing antegrade cannulation of the SFA a 'J' wire is more likely to be successful than a straight guide wire

  8. Birds of the Reserva Biológica do Mato Grande and surroundings, Rio Grande do Sul, Brazil

    DEFF Research Database (Denmark)

    Vizentin-Bugoni, Jeferson; Jacobs, Fernando; Coimbra, Marco Antônio Afonso

    2015-01-01

    The Reserva Biológica do Mato Grande encompasses 5,161 hectares of wetlands, restinga forests and grasslands in southern Brazil. Aiming to assemble a list of bird species occurring in the reserve, we carried out 21 monthly expeditions from July 2007 to March 2009 and an additional visit on October...

  9. Josephson junctions of multiple superconducting wires

    Science.gov (United States)

    Deb, Oindrila; Sengupta, K.; Sen, Diptiman

    2018-05-01

    We study the spectrum of Andreev bound states and Josephson currents across a junction of N superconducting wires which may have s - or p -wave pairing symmetries and develop a scattering matrix based formalism which allows us to address transport across such junctions. For N ≥3 , it is well known that Berry curvature terms contribute to the Josephson currents; we chart out situations where such terms can have relatively large effects. For a system of three s -wave or three p -wave superconductors, we provide analytic expressions for the Andreev bound-state energies and study the Josephson currents in response to a constant voltage applied across one of the wires; we find that the integrated transconductance at zero temperature is quantized to integer multiples of 4 e2/h , where e is the electron charge and h =2 π ℏ is Planck's constant. For a sinusoidal current with frequency ω applied across one of the wires in the junction, we find that Shapiro plateaus appear in the time-averaged voltage across that wire for any rational fractional multiple (in contrast to only integer multiples in junctions of two wires) of 2 e /(ℏ ω ) . We also use our formalism to study junctions of two p -wave and one s -wave wires. We find that the corresponding Andreev bound-state energies depend on the spin of the Bogoliubov quasiparticles; this produces a net magnetic moment in such junctions. The time variation of these magnetic moments may be controlled by an external voltage applied across the junction. We discuss experiments which may test our theory.

  10. Descrição da larva de último instar e pupa de Epacroplon cruciatum (Aurivillius (Coleoptera, Cerambycidae, Cerambycinae e notas biológica

    Directory of Open Access Journals (Sweden)

    Juares Fuhrmann

    2012-03-01

    Full Text Available Descrição da larva de último instar e pupa de Epacroplon cruciatum (Aurivillius (Coleoptera, Cerambycidae, Cerambycinae e notas biológicas. Último instar larval e pupa do Hexoplonini sul-americano Epacroplon cruciatum (Aurivillius, 1899 são descritos, ilustrados e disponibilizadas notas biológicas.

  11. Accidentes biológicos en estudiantes de medicina de una universidad peruana: prevalencia, mecanismos y factores de riesgo

    Directory of Open Access Journals (Sweden)

    Elizabeth Inga

    2010-03-01

    Full Text Available Introducción: Una de las más serias amenazas que enfrentan los estudiantes de medicina durante su práctica clínica es la posibilidad de exposición a accidentes biológicos, debido en la mayoría de los casos a la inexperiencia y el escaso desarrollo de las habilidades manuales. Objetivos: Establecer la frecuencia, mecanismos, circunstancias y factores de riesgo de los accidentes biológicos ocurridos entre estudiantes de medicina. Diseño: Estudio descriptivo observacional de corte transversal. Institución: Facultad de Medicina, Universidad Nacional Mayor de San Marcos, Lima, Perú. Participantes: Estudiantes de medicina. Metodología: Se aplicó una encuesta estructurada anónima, voluntaria y autoadministrada. Principales medidas de resultados: Accidentes biológicos. Resultados: En total fueron 307 entrevistados. La prevalencia de accidentes biológicos en la población estudiada fue de 51,5% (158/307. La media de accidentes biológicos en el último año fue de 1,06. El 91,1% de los estudiantes del último año presentó al menos un accidente biológico, versus 11,9% en los estudiantes del primer año. Los estudiantes del último año informaron con más frecuencia accidentes de riesgo alto para transmisión de infecciones, siendo 47,6% por pinchazo con objeto punzocortante, y 80,6% tuvo exposición a sangre; los accidentes de riesgo alto son mucho más frecuentes en quirófanos y sala de partos (51,9%. Conclusiones: La prevalencia de accidentes biológicos fue 51,5%, siendo el pinchazo la forma más frecuente. Es necesario desarrollar estrategias que permitan velar por la bioseguridad de los estudiantes de medicina.

  12. Investigation of method for Stainless Steel Welding Wire as a Replacement for Arc Wire Comsumables

    Directory of Open Access Journals (Sweden)

    Koiprasert, H.

    2005-01-01

    Full Text Available Arc spraying as a coating method is being employed in various industrial applications as a part of maintenance service, and also as a surface engineering technique for many machine parts and components. The major cost in producing the arc spray coating is, however, based on the cost of the arc wire comsumables. This project was carried out to investigate the use of the commercially-available gas metal arc welding wire (GMAW wire as a cheaper alternative to the special-purpose arc wire comsumables. The wire material chosen for this early study is the 316L stainless steel, due to its popularity in many applications as a built-up coating for worn parts. The physical properties of the coatings produced from the two sets of 316L stainless steel wire were determined to be different in the percentage of porosity and the oxide content. The mechanical properties, including the tensile bond strength and the wear rate of the coatings produced from the two types of sprayed wire, were also different. This will, in turn, result in a slight difference in the performance of thecoatings.

  13. Basic characteristics of thin wire arc plasma

    International Nuclear Information System (INIS)

    Urushihara, K.; Endoh, N.; Ono, S.; Teii, S.; Ishimura, T.

    1998-01-01

    The investigated plasma was generated by applying an electric current of about 50 A to a copper wire of 48 μm diameter in air. The development in time of emission spectra was measured and relative line intensity ratios were used to determine the temperature. The extension of the plasma was measured with a movable electrostatic probe which was placed next to the thin wire, and the electron density was estimated using the known electron mobility. The electron temperature was typically about 8000 K. On the other hand, the electron density tended to decrease with time from about 3.10 16 cm -3

  14. A Flying Wire System in the AGS

    International Nuclear Information System (INIS)

    Huang, H.; Buxton, W.; Mahler, G.; Marusic, A.; Roser, T.; Smith, G.; Syphers, M.; Williams, N.; Witkover, R.

    1999-01-01

    As the AGS prepares to serve as the injector for RHIC, monitoring and control of the beam transverse emittance become a major and important topic. Before the installation of the flying wire system, the emittance was measured with ionization profile monitors in the AGS, which require correction for space charge effects. It is desirable to have a second means of measuring profile that is less dependent on intensity. A flying wire system has been installed in the AGS recently to perform this task. This paper discusses the hardware and software setup and the capabilities of the system

  15. Quantum conductance in silicon quantum wires

    CERN Document Server

    Bagraev, N T; Klyachkin, L E; Malyarenko, A M; Gehlhoff, W; Ivanov, V K; Shelykh, I A

    2002-01-01

    The results of investigations of electron and hole quantum conductance staircase in silicon quantum wires are presented. The characteristics of self-ordering quantum wells of n- and p-types, which from on the silicon (100) surface in the nonequilibrium boron diffusion process, are analyzed. The results of investigations of the quantum conductance as the function of temperature, carrier concentration and modulation degree of silicon quantum wires are given. It is found out, that the quantum conductance of the one-dimensional channels is observed, for the first time, at an elevated temperature (T >= 77 K)

  16. Mesoscopic NbSe3 wires

    International Nuclear Information System (INIS)

    Zant, H.S.J. van der; Kalwij, A.; Mantel, O.C.; Markovic, N.

    1999-01-01

    We have fabricated wire structures with (sub)micron sizes in the charge-density wave conductor NbSe 3 . Electrical transport measurements include complete mode-locking on Shapiro steps and show that the patterning has not affected the CDW material. Our mesoscopic wires show strong fluctuation and hysteresis effects in the low-temperature current-voltage characteristics, as well as a strong reduction of the phase-slip voltage. This reduction can not be explained with existing models. We suggest that single phase-slip events are responsible for a substantial reduction of the CDW strain in micron-sized systems. (orig.)

  17. EDITORIAL More than a wire More than a wire

    Science.gov (United States)

    Demming, Anna

    2010-10-01

    Nanowires are the natural evolution of the connections in circuits when scaled down to nanometre sizes. On closer inspection, of course, the role of nanowires in developing new technologies is much more than just a current-bearing medium. By sizing the diameters of these objects down to the nanoscale, their properties become increasingly sensitive to factors such as the gas composition, temperature and incident light of their surrounding environment, as well as defects and variations in diameter. What becomes important in modern electronics innovations is not just what is connected, but how. Nanowires had already begun to attract the attention of researchers in the early 1990s as advances in imaging and measurement devices invited researchers to investigate the properties of these one-dimensional structures [1, 2]. This interest has sparked ingenious ways of fabricating nanowires such as the use of a DNA template. A collaboration of researchers at Louisiana Tech University in the US hs provided an overview of various methods to assemble conductive nanowires on a DNA template, including a summary of different approaches to stretching and positioning the templates [3]. Work in this area demonstrates a neat parallel for the role of DNA molecules as the building blocks of life and the foundations of nanoscale device architectures. Scientists at HP Labs in California are using nanowires to shrink the size of logic arrays [4]. One aspect of electronic interconnects that requires particular attention at nanoscale sizes is the effect of defects. The researchers at HP Labs demonstrate that their approach, which they name FPNI (field-programmable nanowire interconnect), is extremely tolerant of the high defect rates likely to be found in these nanoscale structures, and allows reduction in size and power without significantly sacrificing the clock rate. Another issue in scaling down electronics is the trend for an increasing resistivity with decreasing wire width. Researchers

  18. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    You Na Oh

    2015-08-01

    Full Text Available Background: Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Methods: Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Results: Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578, major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99, minor wound complications (3.6% vs. 2.0%, p=0.279, or mediastinitis (0.8% vs. 1.0%, p=1.00. Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068. Conclusion: The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  19. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery.

    Science.gov (United States)

    Oh, You Na; Ha, Keong Jun; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won

    2015-08-01

    Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578), major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99), minor wound complications (3.6% vs. 2.0%, p=0.279), or mediastinitis (0.8% vs. 1.0%, p=1.00). Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068). The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  20. Magnetic anisotropy and anisotropic ballistic conductance of thin magnetic wires

    International Nuclear Information System (INIS)

    Sabirianov, R.

    2006-01-01

    The magnetocrystalline anisotropy of thin magnetic wires of iron and cobalt is quite different from the bulk phases. The spin moment of monatomic Fe wire may be as high as 3.4 μ B , while the orbital moment as high as 0.5 μ B . The magnetocrystalline anisotropy energy (MAE) was calculated for wires up to 0.6 nm in diameter starting from monatomic wire and adding consecutive shells for thicker wires. I observe that Fe wires exhibit the change sign with the stress applied along the wire. It means that easy axis may change from the direction along the wire to perpendicular to the wire. We find that ballistic conductance of the wire depends on the direction of the applied magnetic field, i.e. shows anisotropic ballistic magnetoresistance. This effect occurs due to the symmetry dependence of the splitting of degenerate bands in the applied field which changes the number of bands crossing the Fermi level. We find that the ballistic conductance changes with applied stress. Even for thicker wires the ballistic conductance changes by factor 2 on moderate tensile stain in our 5x4 model wire. Thus, the ballistic conductance of magnetic wires changes in the applied field due to the magnetostriction. This effect can be observed as large anisotropic BMR in the experiment

  1. Comparison of Analysis, Simulation, and Measurement of Wire-to-Wire Crosstalk. Part 2

    Science.gov (United States)

    Bradley, Arthur T.; Yavoich, Brian James; Hodson, Shane M.; Godley, Franklin

    2010-01-01

    In this investigation, we compare crosstalk analysis, simulation, and measurement results for electrically short configurations. Methods include hand calculations, PSPICE simulations, Microstripes transient field solver, and empirical measurement. In total, four representative physical configurations are examined, including a single wire over a ground plane, a twisted pair over a ground plane, generator plus receptor wires inside a cylindrical conduit, and a single receptor wire inside a cylindrical conduit. Part 1 addresses the first two cases, and Part 2 addresses the final two. Agreement between the analysis methods and test data is shown to be very good.

  2. Comparison of Analysis, Simulation, and Measurement of Wire-to-Wire Crosstalk. Part 1

    Science.gov (United States)

    Bradley, Arthur T.; Yavoich, Brian James; Hodson, Shame M.; Godley, Richard Franklin

    2010-01-01

    In this investigation, we compare crosstalk analysis, simulation, and measurement results for electrically short configurations. Methods include hand calculations, PSPICE simulations, Microstripes transient field solver, and empirical measurement. In total, four representative physical configurations are examined, including a single wire over a ground plane, a twisted pair over a ground plane, generator plus receptor wires inside a cylindrical conduit, and a single receptor wire inside a cylindrical conduit. Part 1 addresses the first two cases, and Part 2 addresses the final two. Agreement between the analysis, simulation, and test data is shown to be very good.

  3. Experimental study on underwater electrical explosion of a copper wire

    International Nuclear Information System (INIS)

    Zhou Qing; Zhang Jun; Tan Xiangyu; Ren Baozhong; Zhang Qiaogen

    2010-01-01

    Through analyzing the physical process of underwater electrical wire explosion, electrical wire explosions with copper wires were investigated underwater using pulsed voltage in the time scale of a few microseconds. A self-integrating Rogowsky coil and a voltage divider were used for current and voltage at the wire load, respectively. The shock wave pressure is measured with a piezoelectric pressure probe at the same distance. The current rise rate was adjusted by changing the applied voltage, circuit inductance, length and diameter of copper wire. The change of the current rise rate had a great effect on the process of underwater electrical wire explosion with copper wires. At last, the effect of discharge voltage, circuit inductance, length and diameter of copper wire were obtained on the explosion voltage and current as well as shock wave pressure. (authors)

  4. Acoustic Emission from Elevator Wire Ropes During Tensile Testing

    Science.gov (United States)

    Bai, Wenjie; Chai, Mengyu; Li, Lichan; Li, Yongquan; Duan, Quan

    The acoustic emission (AE) technique was used to monitor the tensile testing process for two kinds of elevator wire ropes in our work. The AE signals from wire breaks were obtained and analyzed by AE parameters and waveforms. The results showed that AE technique can be a useful tool to monitor wire break phenomenon of wire ropes and effectively capture information of wire break signal. The relationship between AE signal characteristics and wire breaks is investigated and it is found that the most effective acoustic signal discriminators are amplitude and absolute energy. Moreover, the wire break signal of two kinds of ropes is a type of burst signal and it is believed that the waveform and spectrum can be applied to analyze the AE wire break signals.

  5. Tungsten wire and tubing joined by nickel brazing

    Science.gov (United States)

    1965-01-01

    Thin tungsten wire and tungsten tubing are brazed together using a contacting coil of nickel wire heated to its melting point in an inert-gas atmosphere. This method is also effective for brazing tungsten to tungsten-rhenium parts.

  6. STRUCTURE AND CHARACTERISTICS OF PATENTED HIGH-CARBON WIRE

    Directory of Open Access Journals (Sweden)

    A. Ju. Borisenko

    2011-01-01

    Full Text Available The influence of bainite structure on mechanical characteristics of wire of steel 80 after patenting is studied. The quantity and structure state of bainite, providing high complex of mechanical characteristics of high-carbon wire, is determined.

  7. Rapport d’étape – Le Système canadien hospitalier d’information et de recherche en prévention des traumatismes : un système de surveillance des blessures dynamique et novateur

    Directory of Open Access Journals (Sweden)

    J. Crain

    2016-01-01

    Full Text Available Ce rapport d’étape sur le Système canadien hospitalier d’information et de recherche en prévention des traumatismes (SCHIRPT, un système de surveillance des blessures et des empoisonnements utilisé par les services d’urgence, décrit le résultat de la migration d’un processus d’entrée et de codage des données centralisé vers le processus décentralisé de l’eSCHIRPT, réalisée en 2011. Ce système sécurisé accroît la souplesse et la rapidité globales du SCHIRPT, attributs clés d’un système de surveillance efficace. La plate-forme intégrée de l’eSCHIRPT permet une entrée de données et un accès aux données en temps quasi réel, comprend des outils conviviaux de gestion et d’analyse des données et facilite la communication et la connectivité au sein du réseau du SCHIRPT grâce à un centre de collaboration en ligne. L’essai pilote mené actuellement sur les outils automatisés de contrôle de données et d’analyse des tendances – destinés à surveiller et à mettre en évidence les données d’entrée à partir de critères prédéfinis (par exemple un nouveau produit de consommation – révèle le potentiel de détection rapide des nouveaux dangers, enjeux et tendances que possède l’eSCHIRPT.

  8. Numerical Simulation of Wire-Coating

    DEFF Research Database (Denmark)

    Wapperom, Peter; Hassager, Ole

    1999-01-01

    A finite element program has been used to analyze the wire-coating process of an MDPE melt. The melt is modeled by a nonisothermal Carreau model. The emphasis is on predicting an accurate temperature field. Therefore, it is necessary to include the heat conduction in the metal parts. A comparison...

  9. Studying superconducting Nb3Sn wire

    CERN Multimedia

    AUTHOR|(CDS)2099575

    2015-01-01

    Studying superconducting Nb3Sn wire. From the current experience from LHC and HL-LHC we know that the performance requirements for Nb3Sn conductor for future circular collider are challenging and should exceed that of present state-of-the-art materials.

  10. Brain Wiring in the Fourth Dimension.

    Science.gov (United States)

    Wernet, Mathias F; Desplan, Claude

    2015-07-02

    In this issue of Cell, Langen et al. use time-lapse multiphoton microscopy to show how Drosophila photoreceptor growth cones find their targets. Based on the observed dynamics, they develop a simple developmental algorithm recapitulating the highly complex connectivity pattern of these neurons, suggesting a basic framework for establishing wiring specificity. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Wire anode for isotope separation apparatus

    International Nuclear Information System (INIS)

    Janes, G.S.; Dotson, J.P.

    1976-01-01

    In uranium enrichment, an electrode structure of thin, tensioned, parallel wires is claimed for use in applying an electric field to a region of a flowing uranium plasma including selectively ionized particles in order to accelerate the ionized particles for separate collection without interfering with the motion of neutral particles. 24 claims, 3 drawing figures

  12. Wire chamber degradation at the Argonne ZGS

    International Nuclear Information System (INIS)

    Haberichter, W.; Spinka, H.

    1986-01-01

    Experience with multiwire proportional chambers at high rates at the Argonne Zero Gradient Synchrotron is described. A buildup of silicon on the sense wires was observed where the beam passed through the chamber. Analysis of the chamber gas indicated that the density of silicon was probably less than 10 ppM

  13. Niobium Titanium and Copper wire samples

    CERN Multimedia

    2009-01-01

    Two wire samples, both for carrying 13'000Amperes. I sample is copper. The other is the Niobium Titanium wiring used in the LHC magnets. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. Magnet coils are made of copper-clad niobium–titanium cables — each wire in the cable consists of 9’000 niobium–titanium filaments ten times finer than a hair. The cables carry up to 12’500 amps and must withstand enormous electromagnetic forces. At full field, the force on one metre of magnet is comparable ...

  14. Description of CBETA magnet tuning wire holders

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, S. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-07-19

    A non-­magnetic insert will be placed directly inside the permanent magnet blocks in every CBETA Halbach magnet in order to hold a set of iron “tuning wires”. These wires have various lengths around the perimeter of the aperture in order to cancel multipole field errors from the permanent magnet blocks.

  15. Cutting bubbles with a single wire

    NARCIS (Netherlands)

    Baltussen, M.W.; Segers, Q.I.E.; Kuipers, J.A.M.; Deen, N.G.

    2017-01-01

    Many gas-liquid-solid contactors, such as trickle bed and bubble slurry columns, suffer from heat and mass transfer limitations. To overcome these limitations, new micro-structured bubble column reactor is proposed. In this reactor, a catalyst coated wire mesh is introduced in a bubble column to cut

  16. Studying superconducting Nb$_{3}$Sn wire

    CERN Multimedia

    AUTHOR|(CDS)2099575

    2015-01-01

    Studying superconducting Nb$_{3}$Sn wire. From the current experience from LHC and HL-LHC we know that the performance requirements for Nb$_{3}$Sn conductor for future circular collider are challenging and should exceed that of present state-of-the-art materials.

  17. Two-wire Interface for Digital Microphones

    NARCIS (Netherlands)

    Groothedde, Wouter; Klumperink, Eric A.M.; Nauta, Bram; Eschauzier, Rudolphe Gustave Hubertus; van Rijn, Nico

    2003-01-01

    A two-wire interface for a digital microphone circuit includes a power line and a ground line. The interface utilizes the ground line as a "voltage active line" to transmit both clock and data signals between the digital microphone circuit and a receiving circuit. The digital microphone circuit

  18. Two-Wire interface for digital microphones

    NARCIS (Netherlands)

    Groothedde, Wouter; Klumperink, Eric A.M.; Nauta, Bram; Eschauzier, Rudolphe Gustave Hubertus; van Rijn, Nico

    2005-01-01

    A two-wire interface for a digital microphone circuit includes a power line and a ground line. The interface utilizes the ground line as a "voltage active line" to transmit both clock and data signals between the digital microphone circuit and a receiving circuit. The digital microphone circuit

  19. Spin polarization of electrons in quantum wires

    OpenAIRE

    Vasilchenko, A. A.

    2013-01-01

    The total energy of a quasi-one-dimensional electron system is calculated using density functional theory. It is shown that spontaneous ferromagnetic state in quantum wire occurs at low one-dimensional electron density. The critical electron density below which electrons are in spin-polarized state is estimated analytically.

  20. Signals analysis of fluxgate array for wire rope defaults

    International Nuclear Information System (INIS)

    Gu Wei; Chu Jianxin

    2005-01-01

    In order to detecting the magnetic leakage fields of the wire rope defaults, a transducer made up of the fluxgate array is designed, and a series of the characteristic values of wire rope defaults signals are defined. By processing the characteristic signals, the LF or LMA of wire rope are distinguished, and the default extent is estimated. The experiment results of the new method for detecting the wire rope faults are introduced

  1. Système expert pour la conception en électronique de puissance

    Science.gov (United States)

    Fezzani, D.; Piquet, H.; Foch, H.

    1996-03-01

    The study that we propose concerns the automatic design of static converters and especially of Uninterrupted Power Supply (UPS). The aim is the development of a tool bringing an assistance in the analysis of the specifications, the choice and design of the structure that best match the application. To realize the design of these UPS, a new approach is presented. Specifications are described in terms of input and output performances (voltage, current, ...). These data are analyzed by using design rules and methods which allows designing the input filter, the output filter, the inverter, the rectifier, etc. In practice, these rules and methods are implemented on a micro computer by use of an “expert system generator” SMECI. We present and justify the modular structure that has been installed, as well as its functioning. L'étude que nous proposons concerne la conception automatique des convertisseurs statiques et en particulier des Alimentations Sans Interruption (ASI). Le but recherché est la mise au point d'un outil apportant une aide à l'analyse du cahier des charges, au choix et au dimensionnement des structures les mieux adaptées. Pour réaliser la conception de ces ASI, une nouvelle approche est présentée. Les spécifications sont décrites par les performances recherchées au niveau des courants et des tensions à l'entrée et à la sortie. Ces données sont analysées par l'emploi de méthodes et de règles de conception permettant ainsi de dimensionner le filtre d'entrée, le filtre de sortie, l'onduleur, le redresseur, etc. Au plan pratique, ces règles et méthodes sont implantées à l'aide du “générateur de système expert” SMECI. Nous présentons et justifions la structure modulaire qui a été mise en place, ainsi que son fonctionnement.

  2. How well can blood pressure be controlled? Progress report on the Systolic Hypertension in Europe Follow-Up Study (Syst-Eur 2

    Directory of Open Access Journals (Sweden)

    Sarti Cinzia

    2001-10-01

    Full Text Available Abstract Background The randomised, double-blind, placebo-controlled Systolic Hypertension in Europe trial (Syst-Eur 1 proved that blood pressure (BP lowering therapy starting with nitrendipine reduces the risk of cardiovascular complications in elderly patients with isolated systolic hypertension. In an attempt to confirm the safety of long-term antihypertensive therapy based on a dihydropyridine, the Syst-Eur patients remained in open follow-up after the end of Syst-Eur 1. This paper presents the second progress report of this follow-up study (Syst-Eur 2. It describes BP control and adherence to study medications. Methods After the end of Syst-Eur 1 all patients, treated either actively or with placebo, were invited either to continue or to start antihypertensive treatment with the same drugs as previously used in the active treatment arm. In order to reach the target BP (sitting SBP Results Of the 3787 eligible patients, 3516 (93% entered Syst-Eur 2. At the last available visit, 72% of the patients were taking nitrendipine. SBP/DBP at entry in Syst-Eur 2 averaged 160/83 mmHg in the former placebo group and 151/80 mmHg in the former active-treatment group. At the last follow-up visit SBP/DBP in the patients previously randomised to placebo or active treatment had decreased by 16/5 mmHg and 7/5 mmHg, respectively. The target BP was reached by 74% of the patients. Conclusion Substantial reductions in systolic BP may be achieved in older patients with isolated systolic hypertension with a treatment strategy starting with the dihydropyridine calcium-channel blocker, nitrendipine, with the possible addition of enalapril and/or hydrochlorothiazide.

  3. Communication and Wiring in the Cortical Connectome

    Directory of Open Access Journals (Sweden)

    Julian eBudd

    2012-10-01

    Full Text Available In cerebral cortex, the huge mass of axonal wiring that carries information between near and distant neurons is thought to provide the neural substrate for cognitive and perceptual function. The goal of mapping the connectivity of cortical axons at different spatial scales, the cortical connectome, is to trace the paths of information flow in cerebral cortex. To appreciate the relationship between the connectome and cortical function, we need to discover the nature and purpose of the wiring principles underlying cortical connectivity. A popular explanation has been that axonal length is strictly minimized both within and between cortical regions. In contrast, we have hypothesized the existence of a multi-scale principle of cortical wiring where to optimise communication there is a trade-off between spatial (construction and temporal (routing costs. Here, using recent evidence concerning cortical spatial networks we critically evaluate this hypothesis at neuron, local circuit, and pathway scales. We report three main conclusions. First, the axonal and dendritic arbor morphology of single neocortical neurons may be governed by a similar wiring principle, one that balances the conservation of cellular material and conduction delay. Second, the same principle may be observed for fibre tracts connecting cortical regions. Third, the absence of sufficient local circuit data currently prohibits any meaningful assessment of the hypothesis at this scale of cortical organization. To avoid neglecting neuron and microcircuit levels of cortical organization, the connectome framework should incorporate more morphological description. In addition, structural analyses of temporal cost for cortical circuits should take account of both axonal conduction and neuronal integration delays, which appear mostly of the same order of magnitude. We conclude the hypothesized trade-off between spatial and temporal costs may potentially offer a powerful explanation for

  4. Processing of flexible high-Tc superconducting wires

    International Nuclear Information System (INIS)

    Lee, B.I.; Modi, V.

    1989-01-01

    Wires superconducting at temperatures above 77 K are produced by using YBa 2 Cu 3 O 7 materials. Flexibility was obtained by support from prefabricated fibers or a metallic coating on the extruded YBa 2 Cu 3 O 7 wires. The microstructure, the T c and the critical current densities of the wires were determined. Processing variables and steps are described

  5. A Laser-Wire System for the International Linear Collider

    International Nuclear Information System (INIS)

    Delerue, N.; Dixit, S.; Gannaway, F.; Howell, D.; Qurshi, M.; Blair, G.; Boogert, S.; Boorman, G.; Driouichi, C.; Deacon, L.; Aryshev, A.; Karataev, P.; Terunuma, N.; Urakawa, J.; Brachmann, A.; Frisch, J.; Ross, M.

    2009-01-01

    A new laser-wire has been installed in the extraction line of the ATF at KEK. It aims at demonstrating that laser-wires can be used to measure micrometre scale beam size. In parallel, studies have been made to specify a laser suitable for the ILC laser-wires.

  6. 46 CFR 111.30-19 - Buses and wiring.

    Science.gov (United States)

    2010-10-01

    ... control wiring must be— (1) Suitable for installation within in a switchboard enclosure and be rated at 90... 46 Shipping 4 2010-10-01 2010-10-01 false Buses and wiring. 111.30-19 Section 111.30-19 Shipping... REQUIREMENTS Switchboards § 111.30-19 Buses and wiring. (a) General. Each bus must meet the requirements of...

  7. 47 CFR 76.802 - Disposition of cable home wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of cable home wiring. 76.802... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring. (a)(1) Upon voluntary termination of cable service by a subscriber in a single unit installation, a...

  8. Lunar Module Wiring Design Considerations and Failure Modes

    Science.gov (United States)

    Interbartolo, Michael

    2009-01-01

    This slide presentation reviews the considerations for the design of wiring for the Lunar Module. Included are a review of the choice of conductors and insulations, the wire splicing (i.e., crimping, and soldering), the wire connectors, and the fabrication of the wire harnesses. The problems in fabrication include the wires being the wrong length, the damage due to the sharp edges, the requried use of temproary protective covers and inadequate training. The problems in the wire harness installation include damge from sharp eges, work on adjacent harnesses, connector damage, and breaking wires. Engineering suggestions from the Apollo-era in reference to the conductors that are reviewed include: the use of plated conductors, and the use of alloys for stronger wiring. In refernce to insulation, the suggestions from Apollo era include the use of polymer tape-wrap wire insulation due to the light weight, however, other types of modern insulation might be more cost-effective. In reference to wire splices and terminal boards the suggestions from the Apollo Era include the use of crimp splices as superior to solder splices, joining multiple wire to a common point using modular plug-ins might be more reliable, but are heavier than crimp splicing. For connectors, the lessons from the Apollo era indicate that a rear environmental seal that does not require additional potting is preferred, and pins should be crimped or welded to the incoming wires and be removable from the rear of the connector.

  9. Experimental investigation of industrial copper deformed by wire ...

    African Journals Online (AJOL)

    drawing on microstructure and physical properties of industrial copper wires. Copper wires were provided by E.N.I.CA.Biskra (Algeria). We investigated some wires with different strain levels (as received, 1.20, 2.10, and ε = 3.35).

  10. Domain observations of Fe and Co based amorphous wires

    International Nuclear Information System (INIS)

    Takajo, M.; Yamasaki, J.

    1993-01-01

    Domain observations were made on Fe and Co based amorphous magnetic wires that exhibit a large Barkhausen discontinuity during flux reversal. Domain patterns observed on the wire surface were compared with those found on a polished section through the center of the wire. It was confirmed that the Fe based wire consists of a shell and core region as previously proposed, however, there is a third region between them. This fairly thick transition region made up of domains at an angle of about 45 degree to the wire axis clearly lacking the closure domains of the previous model. The Co based wire does not have a clear core and shell domain structure. The center of the wire had a classic domain structure expected of uniaxial anisotropy with the easy axis normal to the wire axis. When a model for the residual stress quenched-in during cooling of large Fe bars is applied to the wire, the expected anisotropy is consistent with the domain patterns in the Fe based wire, however, shape anisotropy still plays a dominant role in defining the wire core in the Co based wire

  11. A laser-wire system for the International Linear Collider

    Indian Academy of Sciences (India)

    A new laser-wire has been installed in the extraction line of the ATF at KEK. It aims at demonstrating ... beam size measurements to extract the phase space of the electron and positron ... the laser-wire (LW), instead of a conventional solid wire.

  12. Electronic conductance of quantum wire with serial periodic potential structures

    International Nuclear Information System (INIS)

    Fayad, Hisham M.; Shabat, Mohammed M.; Abdus Salam International Centre for Theoretical Physics, Trieste

    2000-08-01

    A theory based on the total transfer matrix is presented to investigate the electronic conductance in a quantum wire with serial periodic potentials. We apply the formalism in computation of the electronic conductance in a wire with different physical parameters of the wire structure. The numerical results could be used in designing some future quantum electronic devices. (author)

  13. Kirschner Wires : insertion techniques and bone related consequences

    NARCIS (Netherlands)

    Franssen, B.B.G.M.

    2010-01-01

    The Kirschner (K-) wire was first introduced in 1909 by Martin Kirschner. This is a thin unthreaded wire of surgical steel with a diameter of up to three millimeters and a selection of different tips. The use of K-wires is often promoted as a simple technique because of its easy placement,

  14. 76 FR 29266 - Galvanized Steel Wire From China and Mexico

    Science.gov (United States)

    2011-05-20

    ...)] Galvanized Steel Wire From China and Mexico Determinations On the basis of the record \\1\\ developed in the... reason of imports from China and Mexico of galvanized steel wire, provided for in subheading 7217.20.30... subsidized imports of galvanized steel wire from China and Mexico. Accordingly, effective March 31, 2011, the...

  15. 77 FR 28404 - Galvanized Steel Wire From China and Mexico

    Science.gov (United States)

    2012-05-14

    ...)] Galvanized Steel Wire From China and Mexico Determinations On the basis of the record \\1\\ developed in the... reason of imports from Mexico of galvanized steel wire, provided for in subheadings 7217.20.30, 7217.20... galvanized steel wire from China and Mexico were sold at LTFV within the meaning of 733(b) of the Act (19 U.S...

  16. A laser-wire system for the International Linear Collider

    Indian Academy of Sciences (India)

    A new laser-wire has been installed in the extraction line of the ATF at KEK. It aims at demonstrating that laser-wires can be used to measure micrometre scale beam size. In parallel, studies have been made to specify a laser suitable for the ILC laser-wires.

  17. On grouping individual wire segments into equivalent wires or chains, and introduction of multiple domain basis functions

    CSIR Research Space (South Africa)

    Lysko, AA

    2009-06-01

    Full Text Available The paper introduces a method to cover several wire segments with a single basis function, describes related practical algorithms, and gives some results. The process involves three steps: identifying chains of wire segments, splitting the chains...

  18. Feasibility studies on the direct wire readout on wire scanners in electron accelerators

    International Nuclear Information System (INIS)

    Markert, Michael

    2010-10-01

    This bachelor thesis deals essentially with the signal processing of a so-called wire scanner, a special monitor, which comes to application in the beam diagnostics of particle accelerators. In this direct wire readout the voltage signal, which is induced by the particle beam in the measurement wire of the wire scanner, shall be directly read out. The aim of this thesis is to show fundamental considerations and perform studies, which study, whether and how in the future by means of a suited data transmission as well as readout electronics conclusion on the most important parameters of the beam, like position and profile, are possible. The measurement system presented here is divided in three main components: Signal measurement, signal preparation, and signal stretching. A suited test facility was developed and is presented in detail, in which then all components, like for instance the transmission cables, the wire-scanner fork, and the developed measurement circuit, are studied, which are of importance for a faultless signal transmission and presentation. Extensive measurements on the single components, as well as calculations for the signal transmission on and in the wire scanner were performed, whereby a good agreement could be found. Thereafter a comparison and a selection of the component used in this project were made. Furthermore improvement proposals, new constructions, and outlooks are presented, which could be of importance in further works.

  19. K-wire and tension band wire fixation in treating sternoclavicular joint dislocation.

    Science.gov (United States)

    Chen, Qing-yu; Cheng, Shao-wen; Wang, Wei; Lin, Zhong-qin; Zhang, Wei; Kou, Dong-quan; Shen, Yue; Ying, Xiao-zhou; Cheng, Xiao-jie; Lv, Chuan-zhu; Peng, Lei

    2011-02-01

    To evaluate the feasibility and therapeutic effect of treating sternoclavicular joint dislocation by K-wire and tension band wire fixation, and to improve the safety and stability of this technique. This study consisted of 9 cases, 6 males and 3 females with the mean age of 25 years (range, 9-62 years). The causes were traffic accident in 7 cases, falling in 1 case and fight in 1 case. The duration from injury to operation was 2 hours to 7 days. There were 5 left dislocations and 4 right dislocations; 8 anterior dislocations and 1 posterior dislocation, including one combined with left scapular fracture and one with left olecranon fracture. Open reduction and internal fixation using K-wires and tension band wires were performed to treat dislocations. All patients were followed up for 6 to 24 months, 10 months on average. According to Rockwood's rating scale on postoperative sternoclavicular joint, 8 cases achieved excellent outcomes with an average score of 13.88, and the rest case achieved a good outcome with the score of 12. Anatomical reduction was obtained in all cases. There were no such postoperative complications as severe infection, injury to blood vessel and nerve, failure of fixation, etc. Patients were all satisfied with the anatomical reduction and functional recovery. The technique of K-wire and tension band wire fixation is safe, simple, effective, less invasive and has been successfully used in orthopedic surgery. It is effective in treating sternoclavicular joint dislocation though it has some disadvantages.

  20. An interconnecting bus power optimization method combining interconnect wire spacing with wire ordering

    International Nuclear Information System (INIS)

    Zhu Zhang-Ming; Hao Bao-Tian; En Yun-Fei; Yang Yin-Tang; Li Yue-Jin

    2011-01-01

    On-chip interconnect buses consume tens of percents of dynamic power in a nanometer scale integrated circuit and they will consume more power with the rapid scaling down of technology size and continuously rising clock frequency, therefore it is meaningful to lower the interconnecting bus power in design. In this paper, a simple yet accurate interconnect parasitic capacitance model is presented first and then, based on this model, a novel interconnecting bus optimization method is proposed. Wire spacing is a process for spacing wires for minimum dynamic power, while wire ordering is a process that searches for wire orders that maximally enhance it. The method, i.e., combining wire spacing with wire ordering, focuses on bus dynamic power optimization with a consideration of bus performance requirements. The optimization method is verified based on various nanometer technology parameters, showing that with 50% slack of routing space, 25.71% and 32.65% of power can be saved on average by the proposed optimization method for a global bus and an intermediate bus, respectively, under a 65-nm technology node, compared with 21.78% and 27.68% of power saved on average by uniform spacing technology. The proposed method is especially suitable for computer-aided design of nanometer scale on-chip buses. (interdisciplinary physics and related areas of science and technology)

  1. Systèmes d'innovation des pays BRICS (Brésil, Russie, Inde, Chine ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Le Brésil, la Russie, l'Inde, la Chine et l'Afrique du Sud (dits pays BRICS) ont placé l'innovation au coeur de leur stratégie de développement. Toutefois, les chercheurs disposent de très peu de connaissances sur le système d'innovation de chacun de ces pays et sur les répercussions qu'il a sur l'économie. La subvention ...

  2. Détection de dysfonctionnement d'un système amortisseur de véhicule automobile

    OpenAIRE

    Ragot , José; Maquin , Didier; Adrot , Olivier; Boatas , Armand; Jampi , Didier

    2003-01-01

    International audience; Le système d'amortissement d'un véhicule est un organe sensible au vieillissement, à l'usure et à des défauts accidentels ; les conséquences de ces perturbations sur la tenue de route peuvent être critiques et l'on conçoit alors l'intérêt de développer des méthodes de diagnostic capables de renseigner sur l'état de fonctionnement de ce dispositif en fournissant des indicateurs d'alerte de dysfonctionnement. Cette communication apporte quelques éléments méthodologiques ...

  3. Nuestra variedad lingüística como variedad biológica

    Directory of Open Access Journals (Sweden)

    Danilo Salamanca

    2014-05-01

    Full Text Available El estudio se centra en señalar problemas esenciales sobre las consecuencias culturales ante la pérdida de idiomas ancestrales, en particular referido al patrimonio lingüístico indígena centroamericano. Señala algunas relaciones entre este proceso y las discusiones sobre la protección de los ecosistemas biológicos de la región, y llama la atención sobre las políticas que existen o deberían existir, para recuperar y preservar tanto el componente cultural (los idiomas como el natural. This study examines essential problems related to the cultural consequences due to the loss of ancestral languages, especially Central American Indigenous languages. It mentions relationships between this process and discussions about the protection of biological ecosystems in the region, and addresses policies that exist, or should exist, to recover and preserve both cultural (linguistic and natural components.

  4. Mesofauna edáfica: indicador biológico de la calidad del suelo

    Directory of Open Access Journals (Sweden)

    Ana Socarrás

    Full Text Available La búsqueda, el uso y la aplicación de los indicadores de la calidad del suelo se han intensificado en las últimas décadas, debido a la necesidad de preservar este recurso no renovable e indispensable para la vida humana, ante el deterioro creciente. La selección de los indicadores se ha dirigido, fundamentalmente, a conocer el efecto de los usos aplicados y el curso de la rehabilitación de los suelos degradados o contaminados. Los grupos que integran la mesofauna edáfica son sensibles a las perturbaciones naturales y antrópicas del medio, las que provocan cambios en su composición específica y su abundancia, y ocasionan la pérdida de especies y de su diversidad, con la consiguiente disminución de la estabilidad y la fertilidad del suelo. Por ello la mesofauna edáfica es considerada como un buen indicador biológico de su estado de conservación. El número, la densidad y el balance de sus grupos permiten predecir y evaluar las transformaciones ocasionadas por la aplicación de diferentes métodos de producción agrícola en condiciones edafoclimáticas específicas, así como considerar integralmente el funcionamiento del ecosistema.

  5. SPECIFIC FEATURES OF TECHNOLOGY OF MANUFACTURING A ZINC-COATED TUB WIRE FOR MUZZLE (BOTTLE’ HOOD WIRE

    Directory of Open Access Journals (Sweden)

    D. B. Zuev

    2016-01-01

    Full Text Available The paper presents the main technical specifications of galvanized low carbon wire for muzzles (bottle’hood wire, consistent with the exploitation requirements to the wire in the manufacture and use of muzzles. The main criteria when selecting the steel grade and upon selection of the technological processes are given. 

  6. Návrhový systém pro zjištění a kvantifikaci požadavků na řídicí systém inteligentního domu

    OpenAIRE

    Kotík, Miloslav

    2015-01-01

    Bakalářská práce se věnuje analýze požadavků investora na řídicí systém inteligentního domu. Je navržen dotazník jako vodítko projektanta při komunikaci s investorem a tento postup je převeden do interaktivní podoby formuláře. Na základě dotazníku je poté navržen postup pro automatické vyhodnocení a převod zjištěných požadavků investora do seznamu doporučených komponent řídicího systému Tecomat Foxtrot a jeho periferií pro realizaci. První dvě kapitoly práce jsou teoretické a popisují intelig...

  7. Hipótesis de progresión del conocimiento biológico y del conocimiento didáctico del contenido biológico. Parte I: referentes teóricos

    Directory of Open Access Journals (Sweden)

    Édgar Orlay Valbuena Ussa

    2012-04-01

    Full Text Available Este artículo, constituye el primero de una serie de dos, consistentes en el abordaje de dos constituyentes fundamentales del conocimiento profesional del profesor de Biología. Primero se presenta la perspectiva del autor sobre el conocimiento profesional del profesor de Biología, y el conocimiento didáctico del contenido biológico (CDCB; luego, a partir de la revisión de antecedentes y de referentes teóricos, se propone una hipótesis de progresión tanto para el conocimiento biológico (estructuras sintáctica y sustantiva como para el CDCB. Para el caso del primer conocimiento, la hipótesis plantea dos extremos: la perspectiva fisicalista y la visión estructural-sistémica; en cuanto al CDCB, la hipótesis plantea dos polos: el reduccionismo biológico y la perspectiva integradora-transformadora. Posteriormente, en el segundo artículo se presentarán los resultados de investigación, a partir del análisis de datos de estudios obtenidos con futuros profesores de Biología.

  8. Laparoscopic extraction of fractured Kirschner wire from the pelvis

    Directory of Open Access Journals (Sweden)

    Vinaykumar N Thati

    2014-01-01

    Full Text Available Kirschner wire is a sharp stainless steel guide wire commonly used in fixation of fractured bone segments. There are case reports of migrated K wire from the upper limb into the spine and chest, and from the lower limb in to the abdomen and pelvis. Here, we present a case report of accidental intra-operative fracture of K wire during percutaneous femoral nailing for sub-trochanteric fracture of right femur, which migrated in to the pelvis when the orthopaedician tried to retrieve the broken segment of the K wire. This case highlights the use of laparoscopy as minimally invasive surgical option.

  9. NASA requirements and applications environments for electrical power wiring

    International Nuclear Information System (INIS)

    Stavnes, M.W.; Hammond, A.N.

    1992-01-01

    Serious problems can occur from insulation failures in the wiring harnesses of aerospace vehicles. In most recorded incidents, the failures have been identified to be the result of arc tracking, the propagation of an arc along wiring bundles through degradation of insulation. Propagation of the arc can lead to the loss of the entire wiring harness and the functions which it supports. While an extensive database of testing for arc track resistant wire insulations have been developed for aircraft applications, the counterpart requirements for spacecraft are very limited. This paper presents the electrical, thermal, mechanical, chemical, and operational requirements for specification and testing of candidate wiring systems for spacecraft applications

  10. Thermal Aware Floorplanning Incorporating Temperature Dependent Wire Delay Estimation

    DEFF Research Database (Denmark)

    Winther, AndreasThor; Liu, Wei; Nannarelli, Alberto

    2015-01-01

    Temperature has a negative impact on metal resistance and thus wire delay. In state-of-the-art VLSI circuits, large thermal gradients usually exist due to the uneven distribution of heat sources. The difference in wire temperature can lead to performance mismatch because wires of the same length...... can have different delay. Traditional floorplanning algorithms use wirelength to estimate wire performance. In this work, we show that this does not always produce a design with the shortest delay and we propose a floorplanning algorithm taking into account temperature dependent wire delay as one...

  11. Carbon wire chamber at sub-atmospheric pressure

    Energy Technology Data Exchange (ETDEWEB)

    Charles, G., E-mail: charlesg@ipno.in2p3.fr; Audouin, L., E-mail: audouin@ipno.in2p3.fr; Bettane, J.; Dupre, R.; Genolini, B.; Hammoudi, N.; Imre, M.; Le Ven, V.; Maroni, A.; Mathon, B.; Nguyen Trung, T.; Rauly, E.

    2017-05-21

    Present in many experiments, wire and drift chambers have been used in a large variety of shapes and configurations during the last decades. Nevertheless, their readout elements has not evolved much: tungsten, sometimes gold-plated or aluminum, wires. By taking advantage of the developments in the manufacture of conducting carbon fiber, we could obtain interesting improvements for wire detectors. In this article, we present recent tests and simulations using carbon fibers to readout signal in place of traditional tungsten wires. Unlike metallic wires, their low weight guaranties a reduced quantity of material in the active area.

  12. Informatividade dos lucros contábeis e divulgação dos ativos biológicos: evidências brasileiras

    OpenAIRE

    Holanda, Allan Pinheiro

    2013-01-01

    A pesquisa tem o objetivo de investigar a influência exercida pela divulgação dos ativos biológicos na informatividade dos lucros contábeis nas firmas brasileiras listadas na BM&FBovespa, considerando-se o período de 2010 a 2011. Para a investigação da informatividade dos ativos biológicos foi utilizada a adaptação dos modelos propostos por Easton e Harris (1991) e Francis e Schipper (1999). Os ativos biológicos, por sua vez, foram mensurados de duas maneiras, pela simples existência da c...

  13. Ciclo de vida de Triatoma dimidiata Latreille, 1811 (Hemiptera, Reduviidae) en condiciones de laboratorio: producción de ninfas para ensayos biológicos

    OpenAIRE

    Marlene Reyes; Víctor Manuel Angulo

    2009-01-01

    Introducción. A pesar de la importancia de Triatoma dimidiata como vector de la enfermedad de Chagas, poco se conoce de su ciclo biológico y de la producción eficiente de insectos disponibles para ensayos biológicos. Objetivo. Determinar las características del ciclo de vida en el laboratorio y establecer las condiciones del estado nutricional para la producción eficiente de ninfas de V estadio para ensayos biológicos. Materiales y métodos. Se determinaron los tiempos de desarrollo de l...

  14. K-wire and tension band wire fixation in treating sternoclavicular joint dislocation

    Directory of Open Access Journals (Sweden)

    CHEN Qing-yu

    2011-02-01

    Full Text Available 【Abstract】Objective: To evaluate the feasibility and therapeutic effect of treating sternoclavicular joint dislocation by K-wire and tension band wire fixation, and to improve the safety and stability of this technique. Methods: This study consisted of 9 cases, 6 males and 3 females with the mean age of 25 years (range, 9-62 years. The causes were traffic accident in 7 cases, falling in 1 case and fight in 1 case. The duration from injury to operation was 2 hours to 7 days. There were 5 left dislocations and 4 right dislocations; 8 anterior dislocations and 1 posterior dislocation, including one combined with left scapular fracture and one with left olecranon fracture. Open reduction and internal fixation using K-wires and tension band wires were performed to treat dislocations. Results: All patients were followed up for 6 to 24 months, 10 months on average. According to Rockwood’s rating scale on postoperative sternoclavicular joint, 8 cases achieved excellent outcomes with an average score of 13.88, and the rest case achieved a good outcome with the score of 12. Anatomical reduction was obtained in all cases. There were no such postoperative complications as severe infection, injury to blood vessel and nerve, failure of fixation, etc. Patients were all satisfied with the anatomical reduction and functional recovery. Conclusions: The technique of K-wire and tension band wire fixation is safe, simple, effective, less invasive and has been successfully used in orthopedic surgery. It is effective in treating sternoclavicular joint dislocation though it has some disadvantages. Key words: Sternoclavicular joint; Dislocations; Bone wires; Fracture fixation, internal

  15. Superconducting wire for the T-15 toroidal magnet

    International Nuclear Information System (INIS)

    Klimenko, E.Yu.; Kruglov, V.S.; Martovetskij, N.N.

    1987-01-01

    Main characteristics of a wire designed for the T-15 toroidal superconducting magnet production are given. The wire with circulation cooling is a twist of 11 niobium-tin wires 1.5 mm in diameter, joined electrolytically by two copper tubes with 3 mm inside diameter. The wire is capable to carry 10 kA current in the 8.5 T induction field. Wire features and structures promote to receive high structural current density in winding: diffuseness of superconducting-to-normal transition increases wire stability, screw symmetry od a current-carrying core provides wire resistance to pulse longitudinal field effect at plasma current disruption, low bronze thermal conductivity in a twist increases stability to outside pulse perturbations

  16. Development of wire wrapping technology for FBR fuel pin

    International Nuclear Information System (INIS)

    Nogami, Tetsuya; Seki, Nobuo; Sawayama, Takeo; Ishibashi, Takashi

    1991-01-01

    For the FBR fuel assembly, the spacer wire is adopted to maintain the space between fuel pins. The developments have been carried out to achieve automatically wire wrapping with high precision. Based on the fundamental technology developed through the mock-up test operation, Joyo 'MK-I', fuel pin fabrication was started using partially mechanized wire wrapping machine in 1973. In 1978, an automated wire wrapping machine for Joyo 'MK-II' was developed by the adoption of some improvements for the wire inserting system to end plug hole and the precision of wire pitch. On the bases of these experiences, fully automated wire wrapping machine for 'Monju' fuel pin was installed at Plutonium Fuel Production Facility (PFPF) in 1987. (author)

  17. Poliquetos (Annelida: Polychaeta como indicadores biológicos de contaminación marina: casos en Colombia

    Directory of Open Access Journals (Sweden)

    Vanessa Fernández Rodríguez

    2015-06-01

    Full Text Available El concepto de Indicador Biológico ha sido usado sin mayor precaución al momento de emplear ciertos organismos en programas de monitoreo ambiental, lo cual genera confusión. Uno de los objetivos de este trabajo fue resaltar la importancia en la consolidación de una definición precisa de este concepto a partir de información disponible, proponiendo una definición para el mismo. Las características ecológicas de los poliquetos permiten que, al estar en contacto permanente con diferentes tipos de contaminantes, respondan bioacumulando, disminuyendo o aumentando su abundancia, según sea la especie, hecho que posiciona este tipo de organismos como potenciales indicadores de contaminación marina. En este artículo se presenta de manera concreta un análisis de la literatura disponible para poliquetos en el campo de los indicadores biológicos, resaltando cómo éstos han sido usados en diferentes metodologías, con ejemplos a internacionales, así como una selección especial para Colombia. De los resultados más sobresalientes se encontró que Capitella capitata es la especie más estudiada al estar asociada con ambientes contaminados a causa del incremento de materia orgánica y es la única especie reportada en el país como indicador biológico usando las técnicas clásicas de bioindicación. Finalmente, se reitera la importancia de iniciar investigaciones sobre los aspectos ecológicos, ecotoxicológicos y bioensayos de laboratorio con otras especies de poliquetos para validar cuáles especies y por qué pueden ser consideradas como indicadores biológicos para el país.

  18. Investigador Invitado. Control Biológico en Agroecosistemas Mediante el Manejo de Insectos Entomófagos

    Directory of Open Access Journals (Sweden)

    Nicholls Clara Inés

    1998-06-01

    Full Text Available La importancia que tienen los enemigos naturales de los organismos nocivos ha sido reconocida desde hace varias décadas. Desafortunadamente la implantación del control biológico no ha tenido la dimensión deseada. El empleo indiscriminado de productos biocidas ha alterado la biodiversidad de los agroecosistemas. Los parasitoides y predatores han sufrido los efectos nocivos de los plaguicidas. Los enemigos naturales de las plagas juegan un papel trascendental en la regulación las poblaciones de insectos nocivos. Los predatores de la clase insecta se registran en diversos órdenes y la abundancia de especies es impresionante. Pero el conocimiento que se tiene sobre su importancia aún es parcial. Pero el conocimiento que se tiene sobre su importancia aun es parcial. En muchos países no se ha precisado aun la bondad de estos organismos y se les protege. En el caso de los parasitoides ocurre algo similar. Se afirma que su diversidad biótica es incalculable, pero se explotan muy pocas especies. En estos dos grupos descansan los proyectos de Control Biológico clásico. Los éxitos en proyectos de control biológico se reconocen y se han expandido en varios países pero se requiere de un mayor impulso. Debido a las exigencias de una producción agrícola sostenible se debe de apoyar en Control Biológico de Plagas. En este documento se plantean aspectos generales sobre el tema.

  19. Approches par points de vue pour l’ingénierie des Systèmes d’information

    Directory of Open Access Journals (Sweden)

    Brahim Lahna

    2009-07-01

    Full Text Available Les concepts de point de vue, de rôle, de perspective et de vue ont été largement étudiés et utilisés dans de nombreux travaux, dans divers domaines de l’informatique. On retrouve ces notions dans les Systèmes de Représentation de Connaissances par Objets, les Bases de Données Orientées Objets, les Méthodes de Conception, la Programmation Orientée Objets, etc. Chaque domaine lui donne sa propre définition et l’utilise dans son propre contexte. La notion de vue se développe indépendamment dans ces différentes disciplines. Bien que les propositions différent, elles sont confrontées aux mêmes problèmes : établir des relations entre vues et garantir la cohérence des vues entre elles ou vis-à-vis d'un modèle de référence. Nous présentons dans cet article des travaux relatifs aux notions de vues et points de vue dans différentes disciplines informatiques en insistant sur une proposition originale pour une nouvelle ingénierie des systèmes d’information orientée perspectives et composants multivues réutilisables.

  20. Fatores associados à exposição ocupacional com material biológico entre profissionais de enfermagem

    Directory of Open Access Journals (Sweden)

    Nádia Bruna da Silva Negrinho

    Full Text Available RESUMO Objetivo: identificar os fatores associados à exposição ocupacional com material biológico entre profissionais de enfermagem. Método: estudo transversal, realizado em um hospital, de alta complexidade, do interior do Estado de São Paulo, Brasil. Foram entrevistados profissionais de enfermagem no período de março a novembro de 2015. Todos os aspectos éticos foram contemplados. Resultado: dentre 226 profissionais entrevistados, 17,3% sofreram exposição ocupacional com material biológico potencialmente contaminado, sendo 61,5% por via percutânea. Fatores, como a faixa etária (p=0,003, a experiência na enfermagem (p=0,015 e na instituição, (p=0,032 estiveram associados ao acidente. Conclusão: a maior parte dos acidentes com material biológico entre os profissionais de enfermagem ocorreu por via percutânea sendo que a idade, experiência profissional e na instituição compreenderam fatores associados à exposição ocupacional.

  1. The Fine Wire Technique for Flexor Tenolysis

    Science.gov (United States)

    Baltodano, Pablo A.; Weinberg, Maxene H.; Whipple, Lauren A.; Gemmiti, Amanda L.; Whipple, Richard E.

    2017-01-01

    Background: Flexor tenolysis surgery for flexor digitorum profundus and superficialis adhesions is a common procedure performed by hand surgeons. Releasing these adhered tendons can greatly improve hand function and improve quality of life. Recent evidence, however, has shown that the outcomes of tenolysis surgeries are often suboptimal and can result in relapsing adhesions or even tendon ruptures. Methods: This article describes a new technique with potential for reduced complication rates: The Fine Wire Technique for Flexor Tenolysis (FWT). Results: Following FWT, the patient detailed in this article had an excellent recovery of function and no complications: including tendon rupture, infection, hematomas, or any other complications. She reported a major improvement from her preoperative functionality and continues to have this level of success. The wire’s thinness allows for a swift tenolysis. Conclusions: The FWT is a new option available to the hand surgeon associated with good functional results. The wire is readily available to the clinician and is also inexpensive. PMID:29263961

  2. Spontaneous spin polarization in quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Vasilchenko, A.A., E-mail: a_vas2002@mail.ru

    2015-12-04

    The total energy of a quasi-one-dimensional electron system was calculated using the density functional theory. In the absence of a magnetic field, we have found that ferromagnetic state occurs in the quantum wires. The phase diagram of the transition into the spin-polarized state is constructed. The critical electron density below which electrons are in spin-polarized state is estimated analytically. - Highlights: • Density functional theory used to study a spin-polarized state in quantum wires. • The Kohn–Sham equation for quasi-one-dimensional electrons solved numerically. • The phase diagram of the transition into the spin-polarized state is constructed. • The electron density below which electrons are in a spin-polarized state was found. • The critical density of electrons was estimated analytically.

  3. Spontaneous spin polarization in quantum wires

    International Nuclear Information System (INIS)

    Vasilchenko, A.A.

    2015-01-01

    The total energy of a quasi-one-dimensional electron system was calculated using the density functional theory. In the absence of a magnetic field, we have found that ferromagnetic state occurs in the quantum wires. The phase diagram of the transition into the spin-polarized state is constructed. The critical electron density below which electrons are in spin-polarized state is estimated analytically. - Highlights: • Density functional theory used to study a spin-polarized state in quantum wires. • The Kohn–Sham equation for quasi-one-dimensional electrons solved numerically. • The phase diagram of the transition into the spin-polarized state is constructed. • The electron density below which electrons are in a spin-polarized state was found. • The critical density of electrons was estimated analytically.

  4. Disorder and Interaction Effects in Quantum Wires

    International Nuclear Information System (INIS)

    Smith, L W; Ritchie, D A; Farrer, I; Griffiths, J P; Jones, G A C; Thomas, K J; Pepper, M

    2012-01-01

    We present conductance measurements of quasi-one-dimensional quantum wires affected by random disorder in a GaAs/AlGaAs heterostructure. In addition to quantised conductance plateaux, we observe structure superimposed on the conductance characteristics when the channel is wide and the density is low. Magnetic field and temperature are varied to characterize the conductance features which depend on the lateral position of the 1D channel formed in a split-gate device. Our results suggest that there is enhanced backscattering in the wide channel limit, which gives rise to quantum interference effects. When the wires are free of disorder and wide, the confinement is weak so that the mutual repulsion of the electrons forces a single row to split into two. The relationship of this topological change to the disorder in the system will be discussed.

  5. Heat Transfer Analysis in Wire Bundles for Aerospace Vehicles

    Science.gov (United States)

    Rickman, S. L.; Iamello, C. J.

    2016-01-01

    Design of wiring for aerospace vehicles relies on an understanding of "ampacity" which refers to the current carrying capacity of wires, either, individually or in wire bundles. Designers rely on standards to derate allowable current flow to prevent exceedance of wire temperature limits due to resistive heat dissipation within the wires or wire bundles. These standards often add considerable margin and are based on empirical data. Commercial providers are taking an aggressive approach to wire sizing which challenges the conventional wisdom of the established standards. Thermal modelling of wire bundles may offer significant mass reduction in a system if the technique can be generalized to produce reliable temperature predictions for arbitrary bundle configurations. Thermal analysis has been applied to the problem of wire bundles wherein any or all of the wires within the bundle may carry current. Wire bundles present analytical challenges because the heat transfer path from conductors internal to the bundle is tortuous, relying on internal radiation and thermal interface conductance to move the heat from within the bundle to the external jacket where it can be carried away by convective and radiative heat transfer. The problem is further complicated by the dependence of wire electrical resistivity on temperature. Reduced heat transfer out of the bundle leads to higher conductor temperatures and, hence, increased resistive heat dissipation. Development of a generalized wire bundle thermal model is presented and compared with test data. The steady state heat balance for a single wire is derived and extended to the bundle configuration. The generalized model includes the effects of temperature varying resistance, internal radiation and thermal interface conductance, external radiation and temperature varying convective relief from the free surface. The sensitivity of the response to uncertainties in key model parameters is explored using Monte Carlo analysis.

  6. Control biológico del entrenamiento de resistencia. Biological control of endurance training.

    Directory of Open Access Journals (Sweden)

    González Gross, Marcela

    2006-01-01

    Full Text Available ResumenLa alta exigencia en los deportistas de elite hace cada vez más necesario controlar el proceso de adaptación al entrenamiento. El objetivo de esta revisión es analizar la información biológica de un análisis de sangre, al objeto de obtener información de la carga de entrenamiento en atletas de resistencia. La mayor parte de los parámetros sanguíneos han sido empleados, más que para determinar el proceso del entrenamiento, precisamente, para lo opuesto: el sobreentrenamiento. La concentración en plasma de sustratos metabólicos (glucosa y ácidos grasos no son parámetros que pueda utilizarse para controlar el entrenamiento, debido a las bajas especificidad y sensibilidad. No obstante, la concentración de determinados enzimas que intervienen en la utilización de los sustratos puede ser importante. Valores de creatín kinasa superiores a 200 U/l en una persona sana sugiere claramente que la carga de entrenamiento total de una determinada sesión ha sido elevada. La concentración en plasma de algún producto de degradación del catabolismo también puede señalar la adaptación del organismo al entrenamiento. La concentración de ácido láctico en plasma es la herramienta más común en la valoración de la carga de entrenamiento. La concentración de urea es un buen marcador biológico de la carga de entrenamiento. Valores superiores a 8 mmol/l en varones y de 6,5 mmol/l en mujeres, indican que el entrenamiento ha sido muy intenso. La determinación de otros productos (amonio o sustratos (glutamina se han utilizado para detectar el sobreentrenamiento.AbstractThe high exigency in the elite sportsmen does more necessary to control the process of training adaptation. The purpose of this review is to analyze the biological information of a blood analysis to obtain data of load training in endurance athletes. Most blood parameters has been used to evaluate the overtraining state instead of determining the training process. The

  7. From barbed wire to radar traps

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Several million DM are required already to protect the building sites of power plants. From the very beginning concrete, wood, and barbed wire are used to make a protective wall against intruders, or in official German, 'unauthorized persons'. This expensive provisional set-up is later supplanted by electronic alarm and safety systems. A review of available systems helps to give a picture of power plant protection. (orig.) 891 HP [de

  8. Buoyant Helical Twin-Axial Wire Antenna

    Science.gov (United States)

    2016-11-15

    February 2017 The below identified patent application is available for licensing. Requests for information should be addressed to...300169 1 of 9 BUOYANT HELICAL TWIN-AXIAL WIRE ANTENNA CROSS REFERENCE TO OTHER PATENT APPLICATIONS [0001] This application is a divisional...application and claims the benefit of the filing date of United States Patent Application No. 14/280,889; filed on May 19, 2014; and entitled “Twin-Axial

  9. Wire chambers with their magnetostrictive readout

    CERN Multimedia

    1974-01-01

    This set of wire chamber planes shaped as a cylinder sector was installed inside the magnet of a polarized spin target modified to allow as well momentum analysis of the produced particles. The experiment (S126) was set up by the CERN-Trieste Collaboration in the PS beam m9 to measure spin effects in the associated production of of a positive kaon and a positive Sigma by interaction of a positive pion with polarized protons.

  10. Spectral correlations in Anderson insulating wires

    Science.gov (United States)

    Marinho, M.; Micklitz, T.

    2018-01-01

    We calculate the spectral level-level correlation function of Anderson insulating wires for all three Wigner-Dyson classes. A measurement of its Fourier transform, the spectral form factor, is within reach of state-of-the-art cold atom quantum quench experiments, and we find good agreement with recent numerical simulations of the latter. Our derivation builds on a representation of the level-level correlation function in terms of a local generating function which may prove useful in other contexts.

  11. Visible emission from exploding wire in water

    Czech Academy of Sciences Publication Activity Database

    Šimek, Milan; Prukner, Václav; Schmidt, Jiří; Koláček, Karel; Štraus, Jaroslav; Frolov, Oleksandr

    2007-01-01

    Roč. 53, č. 10 (2007), s. 53-53 ISSN 0003-0503. [The 61st Annual Gaseous Electronic Conference. Dallas,Texas, 13.10.2008-17.10.2008] R&D Projects: GA ČR GA202/06/1324 Institutional research plan: CEZ:AV0Z20430508 Keywords : Exploding wire * emission Subject RIV: BL - Plasma and Gas Discharge Physics

  12. Establecimiento de una red de equilibrios biológicos en ecosistemas con presencia de pinsapo (Abies pinsapo Boiss. en Andalucía.

    Directory of Open Access Journals (Sweden)

    Navarro Cerrillo, R. M.

    2004-12-01

    Full Text Available In 2001, the Consejería de Medio Ambiente of the Junta de Andalucía established a Monitoring Network on ecosystems of Abies pinsapo Boiss.for evaluating the phytosanitary state in the natural range areas of A. pinsapo in the Iberian Península: Sierra de las Nieves (Málaga, Spain, Sierra de Grazalema (Cadiz, Spain and Los Reales de Sierra Bermeja (Málaga, Spain. This network is based on a 1 x 1 Km grid established throughout the forest stands where Abies pinsapo is present, given by the Mapa Forestal de España (Spanish land cover map, RUIZ DE LA TORRE, 1990. The Network has been constructed from 35 sample plots, which will be visited annually (in summer in order to assess the state of trees. This article describes the network design process and the main results from the first campaign of sampling.

    [fr]
    En mai 2001, la Consejería de Medio Ambiente-Junta de Andalucía a mis sur pied un Réseau pour la surveillance systématique et multitemporelle de l'état de santé et vitalité des forets de Abies pinsapo Boiss. dans ses aires de répartition naturelle dans la Péninsule Ibérique: Sierra de las Nieves (Málaga, Espagne, Sierra de Grazalema (Cádiz, Espagne et Los Reales de Sierra Bermeja (Málaga, Espagne. Cet inventaire a été réalisé à partir d'un réseau d'échantillonnage systématique selon un maillage de 1 x 1 kilomètres couvrant la surface des forêts avec présence de Abies pinsapo, d'après la Mapa Forestal de España (Carte Forestière Espagnole, RUIZ DE LA TORRE, 1990. Après Rétablissement, l'inventaire a été constitué par 35 parcelles d'observation, qui seront visitées annuellement (en été pour évaluer l'état des arbres. Cette note présente le dessin de ce réseau et les résultats de la première campagne de terrain.
    [es]
    En la primavera del año 2001, la Consejería de Medio Ambiente de la Junta de Andalucía estableció una Red de Equilibrios Biol

  13. Control biológico en el cultivo del arroz en Cuba. (Resultados 1970 – 2005.

    Directory of Open Access Journals (Sweden)

    Rafael Meneses

    2007-12-01

    Full Text Available El cultivo del arroz en Cuba está afectado por diversas plagas, fundamentalmente: Tagosodes orizicolus, Lissorhoptrus brevirostris, Oebalus insularis y Spodoptera frugiperda. A partir de 1970 se iniciaron los estudios sobre los principales controles biológicos de estas plagas. Para T. orizicolus se ha determinado que Paranagrus perforator y Tytthus parviceps son los principales enemigos naturales de esta plaga. El porcentaje de huevos de T. orizicolus parasitados por P. perforator ha llegado al 50.7% en la etapa de germinación a ahijamiento activo de la planta de arroz. Además, a esta plaga se le ha detectado control por los parasitoides Elenchus sp. y Gonatopus sp. L. brevirostris ha sido manejado en los arrozales con los hongos Metarhizium anisopliae y Beauveria bassiana, obteniendo muy buenos resultados, tanto en el control como en las afectaciones ocasionadas por este insecto. La aplicación de M. anisopliae cepa Niña Bonita resulta satisfactorio para el control de O. insularis. Se ha determinado diversos depredadores, parasitoides y hongos que en determinadas épocas del año ejercer buen control de S. frugiperda, destacándose dentro de ellos: Coleomegilla cubensis, Chelonus texanus y Telenomus spp. C. texanus ha presentado un nivel de parasitismo superior al 80.0 % y Telenomus sp. de 93 %, en condiciones de producción arrocera. Con la presencia de arañas en los arrozales se logra disminuir considerablemente las poblaciones de insectos plagas.

  14. Demonstrating diamond wire cutting of the TFTR

    International Nuclear Information System (INIS)

    Rule, K.; Perry, E.; Larson, S.; Viola, M.

    2000-01-01

    The Tokamak Fusion Test Reactor (TFTR) ceased operation in April 1997 and decommissioning commenced in October 1999. The deuterium-tritium fusion experiments resulted in contaminating the vacuum vessel with tritium and activating the materials with 14 Mev neutrons. The total tritium content within the vessel is in excess of 7,000 Curies while dose rates approach 50 mRem/hr. These radiological hazards along with the size of the Tokamak (100 cubic meters) present a unique and challenging task for dismantling. Plasma arc cutting is the current baseline technology for the dismantlement of fission reactors. This technology is typically used because of its faster cutting times. Alternatively, an innovative approach for dismantlement of the TFTR is the use of diamond wire cutting technology. Recent improvements in diamond wire technology have allowed the cutting of carbon steel components such as pipe, plate, and tube bundles in heat exchangers. Some expected benefits of this technology include: significantly reduction in airborne contaminates, reduced personnel exposure, a reduced risk of spread of tritium contamination, and reduced overall costs as compared to using plasma arc cutting. This paper will provide detailed results of the diamond wire cutting demonstration that was completed in September of 1999, on a mock-up of this complex reactor. The results will identify cost, safety, industrial and engineering parameters, and the related performance of each situation

  15. Transport properties of different BSCCO wires

    International Nuclear Information System (INIS)

    Metra, P.; Gherardi, L.; Vellego, G.; Masini, R.; Zannella, S.

    1990-01-01

    This paper reports on two classes of solver sheathed BSCCO wires and laminates were prepared from 2223 (Pb substituted) and 2212 powders, respectively, by the powder in tube method. By suitable heat treatments (sintering and annealing below the melting temperature for 2223, melting + annealing for 2212), we obtained sample wires with Tc of ∼110 and ∼85 K respectively, comparable Jc at 77 K (∼10 3 A/cm 2 ), and dramatically different transport behavior. Measurements of critical current at different temperatures and as a function of applied magnetic field were carried out, to characterize the two classes of samples, together with other electrical testing (e.g. d.c. susceptibility) and structural analyses. The granular nature of the higher Tc BSCCO, qualitatively similar to the one of YBCO, was well documented. The melt-processed material showed no apparent granularity, but very strong field dependence of Jc at high temperature. The effect of mechanical deformation on Jc was also investigated by bending samples on different diameters before and after heat treatment. Wires and tapes with 2212 were found to be bendable on very small diameters before treatment, but also the 2223 filled samples were shown to accept significant deformation before sintering

  16. NA48: Wiring up for Change

    CERN Multimedia

    2001-01-01

    The NA48 Collaboration is rebuilding its drift chambers ready for the experiment to start up again this coming July. An intricate task involving the soldering of over 24,000 wires! The future of the NA48 experiment is coming right down to the wire, that is, the wires which the Collaboration is installing in the clean room of Hall 887 on the Prévessin site. Six days a week, technicians are working in shifts to rebuild the experiment's drift chambers. The original chambers were damaged when a section of a vacuum tube imploded at the end of 1999. A year ago, CERN gave the green light for this essential part of the spectrometer to be rebuilt, so the NA48 experiment, which studies CP violation (see box), still has a bright future ahead of it. Three years of data-taking ahead The NA48 experiment aims to penetrate the secrets of CP (Charge Parity) violation. Charge and parity are two parameters which distinguish a particle from an antiparticle. In other words, an electron possesses a negative electric ...

  17. Reliability of the wire drawing dies

    International Nuclear Information System (INIS)

    Sheikh, A.K.; Khany, S.E.

    1993-01-01

    A wear based model is proposed for the dies used in wire drawing process. Using this wear model, it is possible to predict life of the die corresponding to a wear limit criterion. Since various quantities in the model are random in nature the resulting die life will also be random quantity characterized by an appropriate distribution. Using a probabilistic characterization of the parameters of the predictive model, Monte Carlo simulations were conducted to establish the die life distribution. To asses the sensitivity of life distribution with respect to various contributing variables (parameters), the simulation runs were conducted at different levels of these variables (parameters). It is shown that wire drawing die life is Weibull distributed. To compare the simulated results with actual time to failure, data of dies was obtained from a large wire drawing company and was compared with corresponding scenario generated by Monte Carlo simulation. Results obtained by Monte Carlo simulations were very close to the actual time to failure data. (author)

  18. A Prototype Wire Position Monitoring System

    International Nuclear Information System (INIS)

    Wang, Wei

    2010-01-01

    The Wire Position Monitoring System (WPM) will track changes in the transverse position of LCLS Beam Position Monitors (BPMs) to 1(micro)m over several weeks. This position information will be used between applications of beam based alignment to correct for changes in component alignment. The WPM system has several requirements. The sensor range must be large enough so that precision sensor positioning is not required. The resolution needs to be small enough so that the signal can be used to monitor motion to 1(micro)m. The system must be stable enough so that system drift does not mimic motion of the component being monitored. The WPM sensor assembly consists of two parts, the magnetic sensor and an integrated lock-in amplifier. The magnetic sensor picks up a signal from the alternating current in a stretched wire. The voltage v induced in the sensor is proportional to the wire displacement from the center of the sensor. The integrated lock-in amplifier provides a DC output whose magnitude is proportional to the AC signal from the magnetic sensor. The DC output is either read on a digital voltmeter or digitized locally and communicated over a computer interface.

  19. Demonstrating diamond wire cutting of the TFTR

    Energy Technology Data Exchange (ETDEWEB)

    Rule, K.; Perry, E.; Larson, S.; Viola, M. [and others

    2000-02-24

    The Tokamak Fusion Test Reactor (TFTR) ceased operation in April 1997 and decommissioning commenced in October 1999. The deuterium-tritium fusion experiments resulted in contaminating the vacuum vessel with tritium and activating the materials with 14 Mev neutrons. The total tritium content within the vessel is in excess of 7,000 Curies while dose rates approach 50 mRem/hr. These radiological hazards along with the size of the Tokamak (100 cubic meters) present a unique and challenging task for dismantling. Plasma arc cutting is the current baseline technology for the dismantlement of fission reactors. This technology is typically used because of its faster cutting times. Alternatively, an innovative approach for dismantlement of the TFTR is the use of diamond wire cutting technology. Recent improvements in diamond wire technology have allowed the cutting of carbon steel components such as pipe, plate, and tube bundles in heat exchangers. Some expected benefits of this technology include: significantly reduction in airborne contaminates, reduced personnel exposure, a reduced risk of spread of tritium contamination, and reduced overall costs as compared to using plasma arc cutting. This paper will provide detailed results of the diamond wire cutting demonstration that was completed in September of 1999, on a mock-up of this complex reactor. The results will identify cost, safety, industrial and engineering parameters, and the related performance of each situation.

  20. Spin-charge separation in quantum wires

    International Nuclear Information System (INIS)

    Yacoby, A.

    2004-01-01

    Full Text:Using momentum resolved tunneling between two clean parallel quantum wires in a AlGaAs/GaAs heterostructure we directly measure the dispersion of the quantum many-body modes in ballistic wires and follow their dependence on Coulomb interactions by varying the electron density. We find clear signatures of three excitation modes in the data: The anti-symmetric charge mode of the coupled wire system and two spin modes. The density dependence of the anti-symmetric charge mode agrees well with Luttinger-liquid theory. As the density of electrons is lowered, the Coulomb interaction is seen to become increasingly dominant leading to excitation velocities that are up to 2.5 times faster than the bare Fermi velocity, determined experimentally from the carrier density. The symmetric charge excitation, also expected from theory, is, however, not visible in the data. The observed spin velocities are found to be 25% slower than the bare Fermi velocities and depend linearly on carrier density. The dispersions are mapped down to a critical density at which spontaneous localization is observed. Some of the experimental findings concerning this phase will be discussed

  1. Contact conductance between graphene and quantum wires

    International Nuclear Information System (INIS)

    Li Haidong; Zheng Yisong

    2009-01-01

    The contact conductance between graphene and two quantum wires which serve as the leads to connect graphene and electron reservoirs is theoretically studied. Our investigation indicates that the contact conductance depends sensitively on the graphene-lead coupling configuration. When each quantum wire couples solely to one carbon atom, the contact conductance vanishes at the Dirac point if the two carbon atoms coupling to the two leads belong to the same sublattice of graphene. We find that such a feature arises from the chirality of the Dirac electron in graphene. Such a chirality associated with conductance zero disappears when a quantum wire couples to multiple carbon atoms. The general result irrelevant to the coupling configuration is that the contact conductance decays rapidly with the increase of the distance between the two leads. In addition, in the weak graphene-lead coupling limit, when the distance between the two leads is much larger than the size of the graphene-lead contact areas and the incident electron energy is close to the Dirac point, the contact conductance is proportional to the square of the product of the two graphene-lead contact areas, and inversely proportional to the square of the distance between the two leads

  2. Results of the Fermilab wire production program

    International Nuclear Information System (INIS)

    Strauss, B.P.; Remsbottom, R.H.; Reardon, P.J.; Curtis, C.W.; McDonald, W.K.

    1976-01-01

    In examining the various schedules of wire drawing and heat treating, the Critchlow type of schedule provided the highest and most uniform data from billet to billet. It consists of a long anneal at 400 +- 20 0 C at a cold work point giving about 99 percent reduction in area from the extrusion size. Several quick copper anneals at 300 0 C may be interspersed to aid in fabrication. A final anneal at finished size both peaks up the resistivity ratio of the copper as well as the critical current of the alloy by moving dislocations to subcell walls. Using this method, critical currents of 1.7 x 10 5 A/cm 2 could be maintained in all billets. The copper cladding and sinking method looks promising and should save production costs. In spite of this, it was important to attain good packing density in the billets to assure uniform filament pattern and reduce breakage in wire drawing. Overall, a procedure was found for fabricating wire in large production lots that would be acceptable for constructing dipole magnets. It is felt that this method could be peaked up with time

  3. Numerical Investigation of Corrugated Wire Mesh Laminate

    Directory of Open Access Journals (Sweden)

    Jeongho Choi

    2013-01-01

    Full Text Available The aim of this work is to develop a numerical model of Corrugated Wire Mesh Laminate (CWML capturing all its complexities such as nonlinear material properties, nonlinear geometry and large deformation behaviour, and frictional behaviour. Development of such a model will facilitate numerical simulation of the mechanical behaviour of the wire mesh structure under various types of loading as well as the variation of the CWML configuration parameters to tailor its mechanical properties to suit the intended application. Starting with a single strand truss model consisting of four waves with a bilinear stress-strain model to represent the plastic behaviour of stainless steel, the finite element model is gradually built up to study single-layer structures with 18 strands of corrugated wire meshes consistency and double- and quadruple-layered laminates with alternating crossply orientations. The compressive behaviour of the CWML model is simulated using contact elements to model friction and is compared to the load-deflection behaviour determined experimentally in uniaxial compression tests. The numerical model of the CWML is then employed to conduct the aim of establishing the upper and lower bounds of stiffness and load capacity achievable by such structures.

  4. Etude empirique de la relation entre le système monétaire et financier et la croissance économique

    OpenAIRE

    Ouni, Moez; Nejadan-Zarin, Milad

    2011-01-01

    La problématique de la relation entre le système financier, et de ses effets, et la croissance économique reste une question controversée. Elle est sujet d’un débat animé entre les différentes tendances économiques. L’objectif de la présente thèse est d’apporter des éclairages sur la nature de ladite relation. Pour atteindre cet objectif, Nous avons considéré le système financier composé du système bancaire, y compris la banque centrale, et de la bourse de valeurs, et la croissance économique...

  5. Using wire shaping techniques and holographic optics to optimize deposition characteristics in wire-based laser cladding.

    Science.gov (United States)

    Goffin, N J; Higginson, R L; Tyrer, J R

    2016-12-01

    In laser cladding, the potential benefits of wire feeding are considerable. Typical problems with the use of powder, such as gas entrapment, sub-100% material density and low deposition rate are all avoided with the use of wire. However, the use of a powder-based source material is the industry standard, with wire-based deposition generally regarded as an academic curiosity. This is because, although wire-based methods have been shown to be capable of superior quality results, the wire-based process is more difficult to control. In this work, the potential for wire shaping techniques, combined with existing holographic optical element knowledge, is investigated in order to further improve the processing characteristics. Experiments with pre-placed wire showed the ability of shaped wire to provide uniformity of wire melting compared with standard round wire, giving reduced power density requirements and superior control of clad track dilution. When feeding with flat wire, the resulting clad tracks showed a greater level of quality consistency and became less sensitive to alterations in processing conditions. In addition, a 22% increase in deposition rate was achieved. Stacking of multiple layers demonstrated the ability to create fully dense, three-dimensional structures, with directional metallurgical grain growth and uniform chemical structure.

  6. Thermosonic wire bonding of gold wire onto copper pad using the saturated interfacial phenomena

    Science.gov (United States)

    Jeng, Yeau-Ren; Aoh, Jong-Hing; Wang, Chang-Ming

    2001-12-01

    Copper has been used to replace conventional aluminium interconnection to improve the performance of deep submicron integrated circuits. This study used the saturated interfacial phenomena found in thermosonic ball bonding of gold wire onto aluminium pad to investigate thermosonic ball bonding of gold wire onto copper pad. The effects of preheat temperatures and ultrasonic powers on the bonding force were investigated by using a thermosonic bonding machine and a shear tester. This work shows that under proper preheat temperatures, the bonding force of thermosonic wire bonding can be explained based on interfacial microcontact phenomena such as energy intensity, interfacial temperature and real contact area. It is clearly shown that as the energy intensity is increased, the shear force increases, reaches a maximum, and then decreases. After saturation, i.e. the establishment of maximum atomic bonding, any type of additional energy input will damage the bonding, decreasing the shear force. If the preheat temperature is not within the proper range, the interfacial saturation phenomenon does not exist. For a preload of 0.5 N and a welding time of 15 ms in thermosonic wire bonding of gold wire onto copper pads, a maximum shear force of about 0.33 N is found where the interfacial energy intensity equals 1.8×106 J m-2 for preheat temperatures of 150°C and 170°C. Moreover, the corresponding optimal ultrasonic power is about 110 units.

  7. Tentative d'évaluation du systéme d'information marketing au niveau des banques publiques Algériennes

    OpenAIRE

    Hassaine-kazi-tani, Amel

    2014-01-01

    Le premier chapitre présente les fondements théoriques relatifs au marketing, marketing des services et notamment le marketing bancaire.dans le deuxiéme chapitre seront développées les notions de base du concept d'information et celui de systéme d'information et puis le systéme d'information marketing.le troisiéme chapitre pratique présente une étude de cas auprés des banques publiques Algériennes.

  8. Optimization of the Single Staggered Wire and Tube Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Arsana I Made

    2016-01-01

    Full Text Available Wire and tube heat exchanger consists of a coiled tube, and wire is welded on the two sides of it in normal direction of the tube. Generally,wire and tube heat exchanger uses inline wire arrangement between the two sides, whereas in this study, it used staggered wire arrangement that reduces the restriction of convection heat transfer. This study performed the optimization of single staggered wire and tube heat exchanger to increase the capacity and reduce the mass of the heat exchanger. Optimization was conducted with the Hooke-Jeeves method, which aims to optimize the geometry of the heat exchanger, especially on the diameter (dw and the distance between wires (pw. The model developed to present heat transfer correlations on single staggered wire and tube heat exchanger was valid. The maximum optimization factor obtained when the diameter wire was 0.9 mm and the distance between wires (pw was 11 mm with the fref value = 1.5837. It means that the optimized design only using mass of 59,10 % and could transfer heat about 98,5 % from the basis design.

  9. Corrosion fatigue behaviors of steel wires used in coalmine

    International Nuclear Information System (INIS)

    Wang, Songquan; Zhang, Dekun; Chen, Kai; Xu, Linmin; Ge, Shirong

    2014-01-01

    Highlights: • The CF life of steel wire in acid solution is the shortest. • The fatigue source zone showed dimple morphology when coupled with anode potential. • The area of dimple increases with the increase of the applied anode potential. • The strong cathode potential cannot reduce the CF life of the smooth steel wire. • The hydrogen impacted mainly on the plastic deformation of the wire surface. - Abstract: The corrosion fatigue (CF) behaviors of the mining steel wire in different solutions at different applied polarization potentials were investigated in this paper. The surfaces and fracture morphologies of the steel wire at different applied potentials were observed by scanning electron microscope (SEM). The results showed that the CF life of steel wire in acid solution is the shortest. Moreover, the strong anodic polarization potential greatly reduced the CF life of steel wire, while the strong cathode potential did not reduce the CF life. For the smooth steel wire, the hydrogen impacted mainly on the plastic deformation of the wire surface. There was obvious dimple in the fatigue source zone of the wire when coupled with anode potential, and the area of the dimple increased with the increase of the applied anode potential. Conversely, the fatigue source zone of the fracture was relatively smooth at cathode polarization potential, which indicated that the crack propagation followed the mechanism of hydrogen induced cracking

  10. Body of Knowledge (BOK) for Copper Wire Bonds

    Science.gov (United States)

    Rutkowski, E.; Sampson, M. J.

    2015-01-01

    Copper wire bonds have replaced gold wire bonds in the majority of commercial semiconductor devices for the latest technology nodes. Although economics has been the driving mechanism to lower semiconductor packaging costs for a savings of about 20% by replacing gold wire bonds with copper, copper also has materials property advantages over gold. When compared to gold, copper has approximately: 25% lower electrical resistivity, 30% higher thermal conductivity, 75% higher tensile strength and 45% higher modulus of elasticity. Copper wire bonds on aluminum bond pads are also more mechanically robust over time and elevated temperature due to the slower intermetallic formation rate - approximately 1/100th that of the gold to aluminum intermetallic formation rate. However, there are significant tradeoffs with copper wire bonding - copper has twice the hardness of gold which results in a narrower bonding manufacturing process window and requires that the semiconductor companies design more mechanically rigid bonding pads to prevent cratering to both the bond pad and underlying chip structure. Furthermore, copper is significantly more prone to corrosion issues. The semiconductor packaging industry has responded to this corrosion concern by creating a palladium coated copper bonding wire, which is more corrosion resistant than pure copper bonding wire. Also, the selection of the device molding compound is critical because use of environmentally friendly green compounds can result in internal CTE (Coefficient of Thermal Expansion) mismatches with the copper wire bonds that can eventually lead to device failures during thermal cycling. Despite the difficult problems associated with the changeover to copper bonding wire, there are billions of copper wire bonded devices delivered annually to customers. It is noteworthy that Texas Instruments announced in October of 2014 that they are shipping microcircuits containing copper wire bonds for safety critical automotive applications

  11. Évaluation de l'apport des pluies prévues par le système opérationnel AROME-PI dans le système Vigicrues-Flash

    OpenAIRE

    Demargne, J.; Javelle, P.

    2016-01-01

    / Cette étude a été réalisée pour le SCHAPI (Service Central d'Hydrométéorologie et d'Appui à la Prévision des Inondations) pour analyser l'amélioration du système d'avertissement sur la possibilité de crues rapides en intégrant des prévisions de pluie future à courte échéance et fine résolution spatio-temporelle et en prenant en compte leurs incertitudes. Le SCHAPI développe actuellement un service d'avertissement automatisé valable sur l'ensemble de la France, appelé Vigicrues-Flash, qui de...

  12. Avifauna en sistemas silvopastoriles en el Corredor Biológico Mesoamericano, Tabasco, México

    Directory of Open Access Journals (Sweden)

    Noel González-Valdivia

    2014-09-01

    Full Text Available Los sistemas silvopastoriles contienen rasgos ecológicos y económicos que contribuyen con la conservación de comunidades florísticas y faunísticas que en ellas se desarrollan. Entre otras comunidades faunísticas se encuentra la avifauna la cual es un grupo representativo de las alteraciones del habitat, tanto a nivel específico como grupo functional. Con el objetivo de atender la iniciativa de Corredor Biológico Mesoamericano en Tabasco, México, se analizó la diversidad de aves en dos sistemas silvopastoriles: árboles dispersos en potreros (ADP y árboles en cercos o linderos (AL. Se aplicó el método de punto de conteo de radio fijo en tres sitios prioritarios del CBM de Tabasco, ubicados en los municipios: Huimanguillo, Tacotalpa y Tenosique. Los datos provienen de las estaciones seca y húmeda del 2011. Se registraron 2 084 aves de 154 especies (79-89% del esperado y 36 familias. Se detectaron 92, 87 y 85 especies, incluyendo 35 protegidas, con 23, 19 y 16 en Huimanguillo, Tacotalpa y Tenosique, respectivamente. Todos los sitios mostraron alta diversidad (H’≥3.20, baja dominancia de especies (D≥0.08 y alta equidad (J≥0.77. La composición de especies mostró diferencias entre sitios, con mayor similitud entre Tacotalpa y Tenosique. Diez especies pueden considerarse características de los sitios. Aunque en los sistemas silvopastoriles se refugian aves protegidas, el componente arbóreo es poco diverso y corresponde a especies de sucesión secundaria temprana, lo que limita a las aves frugívoras y especialistas de bosque. Diversificar estos sistemas con árboles nativos puede mejorar estos hábitats complementarios e incrementar la conectividad del paisaje para cumplir con los objetivos del CBM en la conservación de la biodiversidad y provisión de bienes a las poblaciones humanas.

  13. La noción de sujeto en Antropología Biológica

    Directory of Open Access Journals (Sweden)

    Lahitte, Héctor Blas

    2005-01-01

    Full Text Available Definir la noción de sujeto en antropología biológica alude-al menos-a dos preguntas: ¿qué es un ser vivo? ¿a partir de qué condición/es nos hacemos humanos?. Sin entrar a discutir la inmensa variedad de posiciones a propósito del entendimiento de lo humano; sí podemos afirmar que todo intento de comprensión fundado en la interacción de naturaleza y entorno posee al menos sentido común. Cualquier batalla que destaque exageradamente la importancia de uno u otro resultará agotadoramente inútil. Mi punto de vista, no respalda ni al nativismo partidario de la herencia ni al ambientalismo partidario del entorno. Creo que herencia y ambiente son dos perspectivas de un saber único para explicar nuestra condición. Los seres humanos somos seres sociales, vivimos nuestro ser cotidiano, en permanente relación con el ser de otros. Al mismo tiempo somos el devenir de experiencias individuales intransferibles. Como seres vivos somos sistemas determinados estructuralmente: todo ocurre en nosotros, a modo de cambios producidos como resultado de nuestra organización interna, o como condición de nuestras interacciones con el medio. -La conducta de cualquier ser vivo es adecuada si sus cambios ocurren en congruencia con los cambios del medio. -Nuestro llegar a ser es siempre resultado de dos procesos: conservación y variación. El dominio social humano, posee un mecanismo fundamental; el lenguaje: surge como característica del proceso que le da origen. Nos hacemos humanos en y por el lenguaje desde él accedemos a la autobservación y autoconciencia. Como bien expresa M. Ridley: "...la naturaleza humana es una mezcla de los principios de Darwin, la herencia de Galton, los instintos de James, los genes de De Vries, los reflejos de Pavlov, las asociaciones de Watson, la historia de Kraepelin, la experiencia positiva de Freud, la cultura de Boas, la división del trabajo de Durkheim, el desarrollo de Piaget y la creación de lazos afectivos de

  14. Method for wrapping a wire round a nuclear fuel rod

    International Nuclear Information System (INIS)

    Nakayasu, Fumio.

    1974-01-01

    Object: To provide a method for winding a wire round a nuclear fuel rod with accurate pitches without imparting any local strain or torsion to the wire. Structure: A wire is fixed on one end of the fuel rod, and the other end of the wire is secured to a universal joint leaving a winding allowance to the fuel rod. The wire is linearly stretched by a predetermined tension through the universal joint so as to provide an angle of development theta corresponding to the desired winding pitch, and then, the fuel rod may be rotated so that the end of the wire on the side of the universal joint is moved towards the fuel rod so as to render the angle of development theta constant in proportion to said rotation of the fuel rod. (Kamimura, M.)

  15. ''Water bath'' effect during the electrical underwater wire explosion

    International Nuclear Information System (INIS)

    Oreshkin, V. I.; Chaikovsky, S. A.; Ratakhin, N. A.; Grinenko, A.; Krasik, Ya. E.

    2007-01-01

    The results of a simulation of underwater electrical wire explosion at a current density >10 9 A/cm 2 , total discharge current of ∼3 MA, and rise time of the current of ∼100 ns are presented. The electrical wire explosion was simulated using a one-dimensional radiation-magnetohydrodynamic model. It is shown that the radiation of the exploded wire produces a thin conducting plasma shell in the water in the vicinity of the exploding wire surface. It was found that this plasma shell catches up to 30% of the discharge current. Nevertheless, it was shown that the pressure and temperature of the wire material remain unchanged as compared with the idealized case of the electrical wire explosion in vacuum. This result is explained by a 'water bath' effect

  16. Failure analysis of the fractured wires in sternal perichronal loops.

    Science.gov (United States)

    Chao, Jesús; Voces, Roberto; Peña, Carmen

    2011-10-01

    We report failure analysis of sternal wires in two cases in which a perichronal fixation technique was used to close the sternotomy. Various characteristics of the retrieved wires were compared to those of unused wires of the same grade and same manufacturer and with surgical wire specifications. In both cases, wire fracture was un-branched and transgranular and proceeded by a high cycle fatigue process, apparently in the absence of corrosion. However, stress anlysis indicates that the effective stress produced during strong coughing is lower than the yield strength. Our findings suggest that in order to reduce the risk for sternal dehiscence, the diameter of the wire used should be increased. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Welding wire velocity modelling and control using an optical sensor

    DEFF Research Database (Denmark)

    Nielsen, Kirsten M.; Pedersen, Tom S.

    2007-01-01

    In this paper a method for controlling the velocity of a welding wire at the tip of the handle is described. The method is an alternative to the traditional welding apparatus control system where the wire velocity is controlled internal in the welding machine implying a poor disturbance reduction....... To obtain the tip velocity a dynamic model of the wire/liner system is developed and verified.  In the wire/liner system it turned out that backlash and reflections are influential factors. An idea for handling the backlash has been suggested. In addition an optical sensor for measuring the wire velocity...... at the tip has been constructed. The optical sensor may be used but some problems due to focusing cause noise in the control loop demanding a more precise mechanical wire feed system or an optical sensor with better focusing characteristics....

  18. Surface cleaning of metal wire by atmospheric pressure plasma

    International Nuclear Information System (INIS)

    Nakamura, T.; Buttapeng, C.; Furuya, S.; Harada, N.

    2009-01-01

    In this study, the possible application of atmospheric pressure dielectric barrier discharge plasma for the annealing of metallic wire is examined and presented. The main purpose of the current study is to examine the surface cleaning effect for a cylindrical object by atmospheric pressure plasma. The experimental setup consists of a gas tank, plasma reactor, and power supply with control panel. The gas assists in the generation of plasma. Copper wire was used as an experimental cylindrical object. This copper wire was irradiated with the plasma, and the cleaning effect was confirmed. The result showed that it is possible to remove the tarnish which exists on the copper wire surface. The experiment reveals that atmospheric pressure plasma is usable for the surface cleaning of metal wire. However, it is necessary to examine the method for preventing oxidization of the copper wire.

  19. Ferromagnetic artificial pinning centers in multifilamentary superconducting wires

    International Nuclear Information System (INIS)

    Wang, J.Q.; Rizzo, N.D.; Prober, D.E.

    1997-01-01

    The authors fabricated multifilamentary NbTi wires with ferromagnetic (FM) artificial pinning centers (APCs) to enhance the critical current density (J c ) in magnetic fields. They used a bundle and draw technique to process the APC wires with either Ni or Fe as the pinning centers. Both wires produced higher J c in the high field range (5-9 T) than previous non-magnetic APC wires similarly processed, even though the authors have not yet optimized pin percentage. Using a magnetometer they found that the pins remained ferromagnetic for the wires with maximum J c . However, they did observe a substantial loss of FM material for the wires where the pin diameter approached 3 nm. Thus, they expect further enhancement of J c with better pin quality

  20. Assimilation des débits dans le modèle hydrologique du système AIGA

    OpenAIRE

    Demargne, J.; Javelle, P.

    2015-01-01

    / Cette étude a été réalisée pour le SCHAPI (Service Central d'Hydrométéorologie et d'Appui à la Prévision des Inondations) et l'Irstea pour tester l'impact d'une assimilation des observations de débit sur les performances du système d'avertissement aux crues rapides AIGA. En collaboration avec l'IRSTEA, le SCHAPI développe actuellement un service d'avertissement automatisé valable sur l'ensemble de la France, qui sera complété par un service expertisé d'avertissement sur des bassins dits pri...

  1. Utilité du système expert Climprod pour la connaissance du déterminisme du recrutement

    OpenAIRE

    Fréon, Pierre; Kwiecinski, B.; Lopez, D.

    1992-01-01

    Une vingtaine de modèles globaux de production comportant une variable climatique ont été proposés (Fréon, 1986). CLIMPROD est un système expert qui permet de choisir, parmi ces modèles, le mieux adapté au stock considéré en fonction de critères objectifs ou empiriques. Le modèle retenu est ensuite ajusté aux données par régression non-linéaire, puis validé par des tests non-paramétriques (jacknife). A partir de quelques exemples pris dans des régions de remontées d'eau profonde, on montre le...

  2. Le système du risque à Saint-Martin (Petites Antilles françaises

    Directory of Open Access Journals (Sweden)

    Virginie Duvat

    2008-11-01

    Full Text Available L’île de Saint-Martin constitue un terrain particulièrement intéressant pour étudier le système du risque naturel et les conditions de la co-évolution territoire/catastrophes. Les mécanismes qui s’y observent renforcent sa vulnérabilité et l’efficacité du retour d’expérience est affaiblie par des blocages d’ordre politique et juridique.The island of Saint-Martin is an interesting case study for a systemic approach applied to cyclone hazards and the co-evolution of territory and disaster management. The mecanisms which can be observed increase its vulnerability and the progress of hazard management policies is weakened by political and juridical bottlenecks.

  3. Prediction of grain deformation in drawn copper wire

    OpenAIRE

    Chang Chao-Cheng; Wang Zi-Wei; Huang Chien-Kuo; Wu Hsu-Fu

    2015-01-01

    Most copper wire is produced using a drawing process. The crystallographic texture of copper wire, which is strongly associated with grain deformation, can have a profound effect on the formability and mechanical and electrical properties. Thus, the ability to predict grain deformation in drawn copper wire could help to elucidate the evolution of microstructure, which could be highly valuable in product design. This study developed a novel method for predicting grain deformation in drawn copp...

  4. Modern trends of aircraft fly-by-wire systems

    Directory of Open Access Journals (Sweden)

    С. С. Юцкевич

    2013-07-01

    Full Text Available Specifics of civil aviation modern transport aircraft fly-by-wire control systems are described. A comparison of the systems-level hardware and software, expressed through modes of guidance, provision of aircraft Airbus A-320, Boeing B-777, Tupolev Tu-214, Sukhoi Superjet SSJ-100 are carried out. The possibility of transition from mechanical control wiring to control through fly-by-wire system in the backup channel is shown.

  5. The sub-wavelength imaging performance of disordered wire media

    International Nuclear Information System (INIS)

    Powell, David A.

    2008-01-01

    An analysis of the sub-wavelength imaging performance of disordered thin wire media is undertaken, in order to understand how its performance may be affected by manufacturing errors. The structure is found to be extremely robust to disorder which keeps the wires parallel. Variation in the orientation of the wires and their longitudinal position causes more significant degradation in the image quality, which is quantified numerically

  6. Wire Rope Failure on the Guppy Winch

    Science.gov (United States)

    Figert, John

    2016-01-01

    On January 6, 2016 at El Paso, the Guppy winch motor was changed. After completion of the operational checks, the load bar was being reinstalled on the cargo pallet when the motor control FORWARD relay failed in the energized position. The pallet was pinned at all locations (each pin has a load capacity of 16,000 lbs.) while the winch was running. The wire rope snapped before aircraft power could be removed. After disassembly, the fractured wire rope was shipped to ES4 lab for further characterization of the wire rope portion of the failure. The system was being operated without a clear understanding of the system capability and function. The proximate cause was the failure of the K48 -Forward Winch Control Relay in the energized position, which allowed the motor to continuously run without command from the hand controller, and operation of the winch system with both controllers connected to the system. This prevented the emergency stop feature on the hand controller from functioning as designed. An electrical checkout engineering work instruction was completed and identified the failed relay and confirmed the emergency stop only paused the system when the STOP button on both connected hand controllers were depressed simultaneously. The winch system incorporates a torque limiting clutch. It is suspected that the clutch did not slip and the motor did not stall or overload the current limiter. Aircraft Engineering is looking at how to change the procedures to provide a checkout of the clutch and set to a slip torque limit appropriate to support operations.

  7. Electron Raman scattering in quantum well wires

    International Nuclear Information System (INIS)

    Zhao Xiangfu; Liu Cuihong

    2007-01-01

    Electron Raman scattering (ERS) is investigated in a semiconductor quantum well wire (QWW) of cylindrical geometry for T=0K and neglecting phonon-assisted transitions. The differential cross-section (DCS) involved in this process is calculated as a function of a scattering frequency and the cylindrical radius. Electron states are confined within a QWW. Single parabolic conduction and valence bands are assumed. The selection rules are studied. Singularities in the spectra are interpreted for various cylindrical radii. ERS discussed here can provide direct information about the electron band structure of the system

  8. In-Situ Wire Damage Detection System

    Science.gov (United States)

    Williams, Martha K. (Inventor); Roberson, Luke B. (Inventor); Tate, Lanetra C. (Inventor); Smith, Trent M. (Inventor); Gibson, Tracy L. (Inventor); Jolley, Scott T. (Inventor); Medelius, Pedro J. (Inventor)

    2014-01-01

    An in-situ system for detecting damage in an electrically conductive wire. The system includes a substrate at least partially covered by a layer of electrically conductive material forming a continuous or non-continuous electrically conductive layer connected to an electrical signal generator adapted to delivering electrical signals to the electrically conductive layer. Data is received and processed to identify damage to the substrate or electrically conductive layer. The electrically conductive material may include metalized carbon fibers, a thin metal coating, a conductive polymer, carbon nanotubes, metal nanoparticles or a combination thereof.

  9. Optical absorption in a thin nickel wire

    OpenAIRE

    INAGAKI, Takashi; Goudonnet, J.P.; ARAKAWA, E.T.

    1986-01-01

    Absorption of a 633-nm phonton in a cylindrical nickel wire with diameter 13 m was measured by a photoacoustic method as a function of angle of phonton incidence . A good photoacoustic signal was obtained with a 6-m W He-Ne laser as a light source without employing focusing optics. The absorption measured for p-polarized phontons was found to be in good agreement with geometrical optics calculation. For s-polarized light, however, significant excess absorption was found for >35.

  10. Optical absorption in a thin nickel wire

    International Nuclear Information System (INIS)

    Inagaki, T.; Goudonnet, J.P.; Arakawa, E.T.

    1986-01-01

    Absorption of a 633-nm photon in a cylindrical nickel wire with diameter 13 μm was measured by a photoacoustic method as a function of angle of photon incidence theta. A good photoacoustic signal was obtained with a 6-mW He-Ne laser as a light source without employing focusing optics. The absorption measured for p-polarized photons was found to be in good agreement with geometrical optics calculation. For s-polarized light, however, significant excess absorption was found for theta > 35 0

  11. The HayWired Earthquake Scenario

    Science.gov (United States)

    Detweiler, Shane T.; Wein, Anne M.

    2017-04-24

    ForewordThe 1906 Great San Francisco earthquake (magnitude 7.8) and the 1989 Loma Prieta earthquake (magnitude 6.9) each motivated residents of the San Francisco Bay region to build countermeasures to earthquakes into the fabric of the region. Since Loma Prieta, bay-region communities, governments, and utilities have invested tens of billions of dollars in seismic upgrades and retrofits and replacements of older buildings and infrastructure. Innovation and state-of-the-art engineering, informed by science, including novel seismic-hazard assessments, have been applied to the challenge of increasing seismic resilience throughout the bay region. However, as long as people live and work in seismically vulnerable buildings or rely on seismically vulnerable transportation and utilities, more work remains to be done.With that in mind, the U.S. Geological Survey (USGS) and its partners developed the HayWired scenario as a tool to enable further actions that can change the outcome when the next major earthquake strikes. By illuminating the likely impacts to the present-day built environment, well-constructed scenarios can and have spurred officials and citizens to take steps that change the outcomes the scenario describes, whether used to guide more realistic response and recovery exercises or to launch mitigation measures that will reduce future risk.The HayWired scenario is the latest in a series of like-minded efforts to bring a special focus onto the impacts that could occur when the Hayward Fault again ruptures through the east side of the San Francisco Bay region as it last did in 1868. Cities in the east bay along the Richmond, Oakland, and Fremont corridor would be hit hardest by earthquake ground shaking, surface fault rupture, aftershocks, and fault afterslip, but the impacts would reach throughout the bay region and far beyond. The HayWired scenario name reflects our increased reliance on the Internet and telecommunications and also alludes to the

  12. Monitoring and evaluation of wire mesh forming life

    Science.gov (United States)

    Enemuoh, Emmanuel U.; Zhao, Ping; Kadlec, Alec

    2018-03-01

    Forming tables are used with stainless steel wire mesh conveyor belts to produce variety of products. The forming tables will typically run continuously for several days, with some hours of scheduled downtime for maintenance, cleaning and part replacement after several weeks of operation. The wire mesh conveyor belts show large variation in their remaining life due to associated variations in their nominal thicknesses. Currently the industry is dependent on seasoned operators to determine the replacement time for the wire mesh formers. The drawback of this approach is inconsistency in judgements made by different operators and lack of data knowledge that can be used to develop decision making system that will be more consistent with wire mesh life prediction and replacement time. In this study, diagnostic measurements about the health of wire mesh former is investigated and developed. The wire mesh quality characteristics considered are thermal measurement, tension property, gage thickness, and wire mesh wear. The results show that real time thermal sensor and wear measurements would provide suitable data for the estimation of wire mesh failure, therefore, can be used as a diagnostic parameter for developing structural health monitoring (SHM) system for stainless steel wire mesh formers.

  13. Metallurgical investigation of wire breakage of tyre bead grade

    Directory of Open Access Journals (Sweden)

    Piyas Palit

    2015-10-01

    Full Text Available Tyre bead grade wire is used for tyre making application. The wire is used as reinforcement inside the polymer of tyre. The wire is available in different size/section such as 1.6–0.80 mm thin Cu coated wire. During tyre making operation at tyre manufacturer company, wire failed frequently. In this present study, different broken/defective wire samples were collected from wire mill for detailed investigation of the defect. The natures of the defects were localized and similar in nature. The fracture surface was of finger nail type. Crow feet like defects including button like surface abnormalities were also observed on the broken wire samples. The defect was studied at different directions under microscope. Different advanced metallographic techniques have been used for detail investigation. The analysis revealed that, white layer of surface martensite was formed and it caused the final breakage of wire. In this present study we have also discussed about the possible reason for the formation of such kind of surface martensite (hard-phase.

  14. Electron transport in quantum wires: possible current instability mechanism

    International Nuclear Information System (INIS)

    Sablikov, V.A.

    2001-01-01

    The electrons nonlinear and dynamic transition in quantum wires connecting the electron reservoirs, are studies with an account of the Coulomb interaction distribution of electron density between the reservoirs and the wire. It is established that there exist two processes, leading to electrical instability in such structure. One of them is expressed in form of multistability of the charge accumulated in the wire, and negative differential conductivity. The other one is connected with origination of negative dynamic conductivity in the narrow frequency range near the resonance frequency of the charge waves on the wire length [ru

  15. Interchip link system using an optical wiring method.

    Science.gov (United States)

    Cho, In-Kui; Ryu, Jin-Hwa; Jeong, Myung-Yung

    2008-08-15

    A chip-scale optical link system is presented with a transmitter/receiver and optical wire link. The interchip link system consists of a metal optical bench, a printed circuit board module, a driver/receiver integrated circuit, a vertical cavity surface-emitting laser/photodiode array, and an optical wire link composed of plastic optical fibers (POFs). We have developed a downsized POF and an optical wiring method that allows on-site installation with a simple annealing as optical wiring technologies for achieving high-density optical interchip interconnection within such devices. Successful data transfer measurements are presented.

  16. Printed Wiring Board Cleaner Technologies Substitutes Assessment: Making Holes Conductive

    Science.gov (United States)

    This document presents comparative risk, competitiveness, and resource requirements on technologies for performing the “making holes conductive” function during printed wiring board manufacturing.

  17. Seeded perturbations in wire array Z-Pinches

    International Nuclear Information System (INIS)

    Robinson, Allen Conrad; Fedin, Dmitry; Kantsyrev, Victor Leonidovich; Wunsch, Scott Edward; Oliver, Bryan Velten; Lebedev, Sergey V.; Coverdale, Christine Anne; Ouart, Nicholas D.; LePell, Paul David; Safronova, Alla S.; Shrestha, I.; McKenney, John Lee; Ampleford, David J.; Rapley, J.; Bott, S.C.; Palmer, J.B.A.; Sotnikov, Vladimir Isaakovich; Bland, Simon Nicholas; Ivanov, Vladimir V.; Chittenden, Jeremy Paul; Jones, B.; Garasi, Christopher Joseph; Hall, Gareth Neville; Yilmaz, M. Faith; Mehlhorn, Thomas Alan; Deeney, Christopher; Pokala, S.; Nalajala, V.

    2005-01-01

    Controlled seeding of perturbations is employed to study the evolution of wire array z-pinch implosion instabilities which strongly impact x-ray production when the 3D plasma stagnates on axis. Wires modulated in radius exhibit locally enhanced magnetic field and imploding bubble formation at discontinuities in wire radius due to the perturbed current path. Wires coated with localized spectroscopic dopants are used to track turbulent material flow. Experiments and MHD modeling offer insight into the behavior of z-pinch instabilities.

  18. Fabrication of mesoscopic floating Si wires by introducing dislocations

    International Nuclear Information System (INIS)

    Motohashi, Mitsuya; Shimizu, Kazuya; Niwa, Masaaki; Suzuki, Toshiaki

    2014-01-01

    We fabricated a mesoscopic Si wire by introducing dislocations in a silicon wafer before HF anodization. The dislocations formed along the (111) crystal plane. The outline of the dislocation line was an inverted triangle. The resulting wire floated on a bridge girder and had a hybrid structure consisting of a porous layer and crystalline Si. The cross section of the wire had an inverted triangle shape. The wire formation mechanism is discussed in terms of carrier transport, crystal structure, and dislocation formation during anodization. (paper)

  19. Fabrication of mesoscopic floating Si wires by introducing dislocations

    Science.gov (United States)

    Motohashi, Mitsuya; Shimizu, Kazuya; Suzuki, Toshiaki; Niwa, Masaaki

    2014-12-01

    We fabricated a mesoscopic Si wire by introducing dislocations in a silicon wafer before HF anodization. The dislocations formed along the (111) crystal plane. The outline of the dislocation line was an inverted triangle. The resulting wire floated on a bridge girder and had a hybrid structure consisting of a porous layer and crystalline Si. The cross section of the wire had an inverted triangle shape. The wire formation mechanism is discussed in terms of carrier transport, crystal structure, and dislocation formation during anodization.

  20. Ultrahigh-strength submicron-sized metallic glass wires

    International Nuclear Information System (INIS)

    Wang, Y.B.; Lee, C.C.; Yi, J.; An, X.H.; Pan, M.X.; Xie, K.Y.; Liao, X.Z.; Cairney, J.M.; Ringer, S.P.; Wang, W.H.

    2014-01-01

    In situ deformation experiments were performed in a transmission electron microscope to investigate the mechanical properties of submicron-sized Pd 40 Cu 30 Ni 10 P 20 metallic glass (MG) wires. Results show that the submicron-sized MG wires exhibit intrinsic ultrahigh tensile strength of ∼2.8 GPa, which is nearly twice as high as that in their bulk counterpart, and ∼5% elastic strain approaching the elastic limits. The tensile strength, engineering strain at failure and deformation mode of the submicron-sized MG wires depend on the diameter of the wires

  1. Fabrication and physical properties of permalloy nano-size wires

    International Nuclear Information System (INIS)

    Yu, C.; Lee, S.F.; Yao, Y.D.; Wong, M.S.; Huang, E.W.; Ma, Y.-R.; Tsai, J.L.; Chang, C.R.

    2003-01-01

    Nano-size NiFe wires with patterned shapes in half-ring-in-series, octagon-in-series, and zigzag-in-series configurations were fabricated. Their magnetoresistance was studied below room temperature and their magnetic domain images were investigated at room temperature by a magnetic force microscope. In general, we have experimentally demonstrated that the variation of the magnetoresistance of our patterned nano-size wires can be related to different domain configurations and explained by the domain switching effect. The number of magnetic domain walls in our patterned wires can be controlled by the shape anisotropy and the size of each section of patterns that form the wires

  2. Anodic Aluminum Oxide Templates for Nano wires Array Fabrication

    International Nuclear Information System (INIS)

    Nur Ubaidah Saidin; Kok, K.Y.; Ng, I.K.

    2011-01-01

    This paper reports on the process developed to fabricate anodic aluminium oxide (AAO) templates suitable for the fabrication of nano wire arrays. Anodization process has been used to fabricate the AAO templates with pore diameters ranging from 15 nm to 30 nm. Electrodeposition of parallel arrays of high aspect ratio nickel nano wires were demonstrated using these fabricated AAO templates. The nano wires produced were characterized using X-ray diffraction (XRD) and scanning electron microscopy (SEM). It was found that the orientations of the electrodeposited nickel nano wires were governed by the deposition current and electrolyte conditions. (author)

  3. Minimally invasive tension band wiring technique for olecranon fractures.

    Science.gov (United States)

    Takada, Naoya; Kato, Kenji; Fukuta, Makoto; Wada, Ikuo; Otsuka, Takanobu

    2013-12-01

    Some types of implants, such as plates, screws, wires, and nails, have been used for open reduction and internal fixation of olecranon fractures. A ≥ 10 cm longitudinal incision is used for open reduction and internal fixation of olecranon fractures. According to previous studies, tension band wiring is a popular method that gives good results. However, back out of the wires after the surgery is one of the main postoperative complications. Moreover, if the Kirschner wires are inserted through the anterior ulnar cortex, they may impinge on the radial neck, supinator muscle, or biceps tendon. Herein, we describe the minimally invasive tension band wiring technique using Ring-Pin. This technique can be performed through a 2 cm incision. Small skin incisions are advantageous from an esthetic viewpoint. Ring-Pin was fixed by using a dedicated cable wire that does not back out unless the cable wire breaks or slips out of the dedicated metallic clamp. As the pins are placed in intramedullary canal, this technique does not lead to postoperative complications that may occur after transcortical fixation by conventional tension band wiring. Minimally invasive tension band wiring is one of the useful options for the treatment of olecranon fractures with some advantages.

  4. L'impact d'une démarche d'alignement stratégique du système d'information sur la stratégie de l'entreprise Cas de SONATRACH

    OpenAIRE

    Taieb Errahmani, Mohamed

    2014-01-01

    Le management des systèmes d'information et des technologies de l'information a apporté de nombreux concepts et pratiques, à savoir ; la gouvernance IT, la gestion stratégique des systèmes d’information… etc. Le concept d’alignement stratégique du système d'information rassemble deux axes principaux, soit ; la stratégie du système d’information et la stratégie de l'entreprise. L'objectif principal de cette étude est de mettre en évidence l'impact d’une démarche d'alignement des systèmes d'inf...

  5. Formation of plasma around wire fragments created by electrically exploded copper wire

    International Nuclear Information System (INIS)

    Taylor, Michael J.

    2002-01-01

    The physical processes occurring during the electrical explosion of metallic conductors has attracted interest for many years. Applications include circuit breakers, segmented lightning divertor strips for aircraft radomes, disruption of metallic shaped charge jets, plasma armatures for electromagnetic railguns and plasma generators for electrothermal-chemical guns. Recent work has cited the phenomenology of the fragmentation processes, particularly the development of a plasma around the lower resistance condensed fragments. An understanding of both the fragmentation process and the development of the accompanying formation of plasma is essential for the optimization of devices that utilize either of these phenomena. With the use of x-radiography and fast photography, this paper explores the wire explosion process, in particular the relationship between the fragmentation, plasma development and resistance rise that occurs during this period. A hypothesis is put forward to account for the development of plasma around the condensed wire fragments. Experimental parameters used in this study are defined. Wires studied were typically copper, with a diameter of 1 mm and length in excess of 150 mm. Circuit inductance used were from 26 to 800 μH. This relatively high circuit inductance gave circuit rise times less than 180 MA s -1 , slow with respect to many other exploding wire studies. Discharge duration ranged from 0.8 to 10 ms. (author)

  6. Percutaneous Kirschner wire (K-wire) fixation for humerus shaft fractures in children: A treatment concept.

    Science.gov (United States)

    Sahu, Ramji Lal

    2013-09-01

    Fractures of the humeral shaft are uncommon, representing less than 10 percent of all fractures in children. Humeral shaft fractures in children can be treated by immobilisation alone. A small number of fractures are unable to be reduced adequately or maintained in adequate alignment, and these should be treated surgically. In the present study, Kirschner wires (K-wire) were used to achieve a closed intramedullary fixation of humeral shaft fractures. The objective of this study was to evaluate the efficacy of intramedullary K-wires for the treatment of humeral shaft fracture in children. This prospective study was conducted in the Department of Orthopaedic surgery in M. M. Medical College from June 2005 to June 2010. Sixty-eight children with a mean age of 7.7 years (range, 2-14 years) were recruited from Emergency and out patient department having closed fracture of humerus shaft. All patients were operated under general anaesthesia. All patients were followed for 12 months. Out of 68 patients, 64 patients underwent union in 42-70 days with a mean of 56 days. Complications found in four patients who had insignificant delayed union which were united next 3 weeks. Intramedullary K-wires were removed after an average of 5 months without any complications. The results were excellent in 94.11% and good in 5% children. This technique is simple, quick to perform, safe and reliable and avoids prolonged hospitalization with good results and is economical.

  7. Mountain Plains Learning Experience Guide: Electrical Wiring. Course: Electrical Wiring Trim-Out.

    Science.gov (United States)

    Arneson, R.; And Others

    One of two individualized courses included in an electrical wiring curriculum, this course covers electrical materials installation for the trim-out stage. The course is comprised of five units: (1) Outlets, (2) Fixtures, (3) Switches, (4) Appliances, and (5) Miscellaneous. Each unit begins with a Unit Learning Experience Guide that gives…

  8. MATHEMATICAL FORMULATION OF PLASTIC CHARACTERISTICS OF WIRE OF STEEL 70 AT HIGH-SPEED WIRE DRAWING

    Directory of Open Access Journals (Sweden)

    Yu. L. Bobarikin

    2011-01-01

    Full Text Available The carried out numerical experiments subject to initial and boundary conditions indicate that mathematical model of elastic-plastic characteristics of steel 90 can be used for numerical calculations of wire drawing routes for this grade of steel.

  9. Wire-number effects on high-power annular z-pinches and some characteristics at high wire number

    Energy Technology Data Exchange (ETDEWEB)

    SANFORD,THOMAS W. L.

    2000-05-23

    Characteristics of annular wire-array z-pinches as a function of wire number and at high wire number are reviewed. The data, taken primarily using aluminum wires on Saturn are comprehensive. The experiments have provided important insights into the features of wire-array dynamics critical for high x-ray power generation, and have initiated a renaissance in z-pinches when high numbers of wires are used. In this regime, for example, radiation environments characteristic of those encountered during the early pulses required for indirect-drive ICF ignition on the NIF have been produced in hohlraums driven by x-rays from a z-pinch, and are commented on here.

  10. Wire-number effects on high-power annular z-pinches and some characteristics at high wire number

    International Nuclear Information System (INIS)

    SANFORD, THOMAS W. L.

    2000-01-01

    Characteristics of annular wire-array z-pinches as a function of wire number and at high wire number are reviewed. The data, taken primarily using aluminum wires on Saturn are comprehensive. The experiments have provided important insights into the features of wire-array dynamics critical for high x-ray power generation, and have initiated a renaissance in z-pinches when high numbers of wires are used. In this regime, for example, radiation environments characteristic of those encountered during the early pulses required for indirect-drive ICF ignition on the NIF have been produced in hohlraums driven by x-rays from a z-pinch, and are commented on here

  11. PERSOREC : un système personnalisé de recommandations pour les folksonomies basé sur les concepts quadratiques

    OpenAIRE

    Jelassi , Mohamed Nader; Ben Yahia , Sadok; Mephu Nguifo , Engelbert

    2015-01-01

    National audience; Ce papier présente un nouveau système personnalisé de recommandations pour les folksonomies basé sur les concepts quadratiques.; This paper introduces a new personalized recommender system for folksonomies based on quadratic concepts.

  12. Predikční systém ELVÍRA pro predikci spotřeby zemního plynu

    Czech Academy of Sciences Publication Activity Database

    Pelikán, Emil; Eben, Kryštof; Šimůnek, Milan; Kolman, M.; Hais, J.

    2000-01-01

    Roč. 80, č. 11 (2000), s. 253-255 ISSN 0032-1761 Institutional research plan: AV0Z1030915 Keywords : predikční modely * systémy pro podporu rozhodování * regresní metody * umělé neuronové sítě Subject RIV: BB - Applied Statistics, Operational Research

  13. 29 CFR 1926.405 - Wiring methods, components, and equipment for general use.

    Science.gov (United States)

    2010-07-01

    ... Electrical Installation Safety Requirements § 1926.405 Wiring methods, components, and equipment for general... lighting wiring methods which may be of a class less than would be required for a permanent installation... subpart for permanent wiring shall apply to temporary wiring installations. Temporary wiring shall be...

  14. El enemigo olvidado: la ricina y su amenaza como arma biológica a los Estados Unidos

    OpenAIRE

    Martínez Pantoja, Yadira Ixchel

    2005-01-01

    El riesgo latente de un ataque terrorista con armas nucleares fue el centro de atención de todas las agencias de seguridad de los Estados Unidos y las naciones aliadas durante la Guerra Fría. Sin embargo, los avances en la genética y la biotecnología han puesto en manos terroristas nuevas armas para vulnerar la seguridad nacional estadounidense: los agentes biológicos. Además, los ataques del 11 de Septiembre modificaron el concepto de seguridad nacional forzando a los depar...

  15. Entendendo o papel de marcadores biológicos no câncer de pulmão

    OpenAIRE

    CAPELOZZI VERA LUIZA

    2001-01-01

    Marcadores biológicos são componentes celulares, estruturais e bioquímicos, que podem definir alterações celulares e moleculares tanto em células normais quanto aquelas associadas a transformação maligna. Podem ser de dois tipos: 1) marcadores intermediários, que medem alterações celulares e moleculares antes do aparecimento da malignidade; 2) marcadores diagnósticos, presentes em associação com a malignidade. O processo de identificação e validação para uso clínico do marcador tem diversas e...

  16. Factores de riesgo para el desarrollo psicomotor en lactantes nacidos en óptimas condiciones biológicas

    OpenAIRE

    Isidora de Andraca; Paulina Pino; Alicia de La Parra; Francisca Rivera; Marcela Castillo

    1998-01-01

    OBJECTIVO: Evaluar el efecto de factores de riesgo para el desarrollo infantil en niños, de nivel socioeconómico bajo, nacidos en óptimas condiciones biológicas pero expuestos a condiciones sociales adversas. METODOLOGÍA: Lactantes de ambos sexos em número de 788, fueron exhaustivamente estudiados en términos de: alimentación, crecimiento, ambiente físico y psicosocial. Se controlaron prospectivamente hasta los 12 meses de edad, momento en que se evaluó el desarrollo mental (MDI) y motor (PDI...

  17. Toxicidad biológica de cepas nativas de Bacillus thuringiensis Berliner en larvas de Tecia solanivora Povolny

    Directory of Open Access Journals (Sweden)

    Paola Martínez

    2011-11-01

    Full Text Available La biodiversidad microbiológica de los suelos del departamento de Boyacá aún no ha sido explorada en toda su magnitud y existen microorganismos, como en el caso de Bacillus thuringiensis Berliner (Bt, que pueden emplearse para el desarrollo de estrategias biológicas de control de plagas en el futuro. Por lo anterior, el presente trabajo evaluó la actividad biológica, expresada como  toxicidad, de cepas nativas de B. thuringiensis en la Polilla Guatemalteca  de  la  papa  Tecia  solanivora Povolny, una de  las plagas más  limitantes en el cultivo de papa en la región andina colombiana. Esta  evaluación  se  realizó con  aislados de  Bt obtenidos y conservados por el Grupo de Manejo Biológico de Cultivos (GMBC en el Laboratorio de Control Biológico de la UPTC, colectados de muestras de  suelo en  la Provincia Centro de Boyacá y  previamente  caracterizados  macro  y microscópicamente.  La   toxicidad  se  evaluó mediante bioensayos con larvas de primer instar de  T.  solanivora,  utilizando  el método  decontaminación superficial de cubos de papa. Se evaluó  la mortalidad  ocho  días  después  de montado  el  bioensayo  y  se  determinó, igualmente,  la Concentración letal media (Cl 50 de las cepas que presentaron  la mayor actividad  tóxica en  los  bioensayos  iniciales.  Los  aislamientosGMBC-B054, GMBC-B071, GMBC-B076, GMBC- B098, GMBC-B111 y GMBC-B117 fueron  los más activos, con Cl 50 de 1.08x106, 4.24x106, 5.12x106, 4.36x103, 3.56x103  y  1.19x104  esporas  · mL-1,respectivamente.

  18. Propuestas para una gestión de la diversidad biológica del Perú

    OpenAIRE

    Vilchez Navarro, María Hortensia; Vilchez Navarro, María Hortensia

    2004-01-01

    El presente documento representa un esfuerzo por encontrar alternativas para mejorar la gestión de la diversidad biológica del Perú desde de una perspectiva global, procurando integrar conservación y desarrollo, bajo el enfoque del desarrollo sostenible. El trabajo consta de cuatro partes que se desarrollan en 14 capítulos. La Primera parte aborda aspectos relativos a los objetivos, la metodología de investigación y el marco teórico que sirven de base para la comprensión de la gestión de la b...

  19. Sintesis y evaluación biológica de nuevos derivados de tipo imidazolina y etanolamina fluorados

    OpenAIRE

    Flores Penalba, Sonia

    2011-01-01

    Una de las principales áreas de interés de la química orgánica es la búsqueda de nuevos compuestos con actividad biológica. En este sentido cabe destacar el especial interés que despiertan los compuestos nitrogenados debido a que constituyen una de las familias más numerosas entre las biomoléculas y que están implicados en múltiples procesos a nivel metabólico y estructural. Un ejemplo representativo los constituyen los compuestos de tipo etanolamina, ampliamente estudiados por sus variad...

  20. Estudios fisicoqu??micos y biol??gicos de un nuevo derivado de la eritromicina: el folato de eritromicina

    OpenAIRE

    Manna, P.K.; Kumaran, V.; Mohanta, G.P.

    2005-01-01

    Se prepar?? un derivado nuevo de la eritromicina, el folato de eritromicina, y se evaluaron sus propiedades fisicoqu??micas y biol??gicas. El derivado presenta una buena solubilidad en metanol, etanol y propileno glicol. Los valores de los coeficientes de partici??n, que fueron 1,12 y 1,10 en sistemas de cloroformo/agua y octanol/agua respectivamente, indican que probablemente se distribuya bien in vivo. La potencia in vitro del derivado, 716 ??g/mg, es mayor que la de derivados e...

  1. Estudio del Efecto de Acciones Químicas y Biológicas sobre la Masa Panaria

    OpenAIRE

    Bot, Beatriz Rosalía Ida

    2010-01-01

    El pan es un producto de consumo masivo al que se le suelen agregar a los ingredientes básicos (harina, agua, levadura y sal) oxidantes, emulsionantes, conservantes, entre otros, para mejorar la calidad del producto. La fermentación es relevante en las características del pan, es realizado por levaduras biológicas ya sean de producción industrial (cepa pura de Saccharomyces cereviceae), o de producción artesanal (masa madre). En el presente trabajo se estudió el efecto d...

  2. Estudo fitoquímico e ensaios biológicos de Davilla Kunthii A. St. Hil (Dilleniaceae)

    OpenAIRE

    Leandro da Silva Nascimento

    2014-01-01

    O uso de plantas ou extratos de plantas para propósitos medicinais tem sido realizado a milhares de anos. O estudo químico e biológico de plantas constitui numa estratégia alternativa na procura de novos agentes terapêuticos para a identificação de compostos bioativos. A espécie Davilla kunthii A. St. Hil, pertencente à família Dilleniaceae, é conhecida popularmente como cipódefogo e podem ser encontradas em regiões de savana. Este trabalho teve como objetivo realizar o estudo fitoquímico e e...

  3. Estudio de procesos biológicos de tratamiento de residuos basado en la modelización

    OpenAIRE

    Magrí Aloy, Albert; Flotats Ripoll, Xavier; Solé-Mauri, Francina; Illa Alibes, Josep

    2006-01-01

    Los modelos matemáticos se han convertido en una herramienta básica para aumentar la comprensión de los procesos biológicos relacionados con el tratamiento de residuos orgánicos. En este sentido, la modelación permite crear un lenguaje de comunicación común, orientar el diseño experimental, evaluar resultados, contrastar hipótesis, revelar relaciones entre variables, prever la evolución de sistemas y, en definitiva, diseñar estrategias de gestión y tratamiento op...

  4. Salud del suelo: en la búsqueda de un indicador biológico de sustentabilidad

    OpenAIRE

    Ortíz, Jimena; Faggioli, Valeria; Ullé, Jorge A.

    2015-01-01

    Los indicadores de calidad de suelo han sido motivo de numerosas investigaciones en los últimos años. Sin embargo, la complejidad en la interpretación de los resultados de laboratorio dificulta su implementación tanto para los productores como para el asesor. Es por ello que el objetivo de este trabajo fue evaluar el comportamiento de indicadores biológicos de suelo sobre diferentes intensidades de manejo orgánico, con énfasis en el coeficiente metabólico. Se analizó un set de datos provenien...

  5. Actividad contra Leishmania sp. (Kinetoplastida: Trypanosomatidae) de plantas en una Reserva Biológica de Costa Rica

    OpenAIRE

    Misael Chinchilla-Carmona; Idalia Valerio-Campos; Ronald Sánchez-Porras; Vanessa Bagnarello-Madrigal; Laura Martínez-Esquivel; Antonieta González-Paniagua; Javier Alpizar-Cordero; Maribel Cordero-Villalobos; Daniela Rodríguez-Chaves

    2014-01-01

    La leishmaniosis es una enfermedad muy importante para el ser humano pero su tratamiento es bastante difícil. Por esta razón muchos investigadores han venido buscando plantas que contengan componentes químicos activos contra esta parasitosis. En Costa Rica no se tienen estudios al respecto y por eso el objetivo de este estudio fue la búsqueda de componentes activos contra Leishmania sp. en plantas de Costa Rica; 67 especies de la Reserva Biológica Alberto Manuel Brenes (REBAMB) fueron selecci...

  6. Antártica: fuente de recursos biológicos para la biotecnología nacional

    OpenAIRE

    Blamey, J.

    2008-01-01

    En diciembre del 2007, Innova-Chile de CORFO aprobó el financiamiento del proyecto “Antártica: Fuente de recursos biológicos para la biotecnología nacional”. Este proyecto tiene como fin crear una plataforma que facilite el acceso a los recursos antárticos de microorganismos y plantas, de una forma que permitirá su valorización para la biotecnología chilena y su desarrollo científico en el área. Por sus únicas condiciones de aislamiento y bajas temperaturas, la Antártica alberga un potencial ...

  7. Fast and High Accuracy Wire Scanner

    CERN Document Server

    Koujili, M; Koopman, J; Ramos, D; Sapinski, M; De Freitas, J; Ait Amira, Y; Djerdir, A

    2009-01-01

    Scanning of a high intensity particle beam imposes challenging requirements on a Wire Scanner system. It is expected to reach a scanning speed of 20 m.s-1 with a position accuracy of the order of 1 μm. In addition a timing accuracy better than 1 millisecond is needed. The adopted solution consists of a fork holding a wire rotating by a maximum of 200°. Fork, rotor and angular position sensor are mounted on the same axis and located in a chamber connected to the beam vacuum. The requirements imply the design of a system with extremely low vibration, vacuum compatibility, radiation and temperature tolerance. The adopted solution consists of a rotary brushless synchronous motor with the permanent magnet rotor installed inside of the vacuum chamber and the stator installed outside. The accurate position sensor will be mounted on the rotary shaft inside of the vacuum chamber, has to resist a bake-out temperature of 200°C and ionizing radiation up to a dozen of kGy/year. A digital feedback controller allows maxi...

  8. Wired and Wireless Camera Triggering with Arduino

    Science.gov (United States)

    Kauhanen, H.; Rönnholm, P.

    2017-10-01

    Synchronous triggering is an important task that allows simultaneous data capture from multiple cameras. Accurate synchronization enables 3D measurements of moving objects or from a moving platform. In this paper, we describe one wired and four wireless variations of Arduino-based low-cost remote trigger systems designed to provide a synchronous trigger signal for industrial cameras. Our wireless systems utilize 315 MHz or 434 MHz frequencies with noise filtering capacitors. In order to validate the synchronization accuracy, we developed a prototype of a rotating trigger detection system (named RoTriDeS). This system is suitable to detect the triggering accuracy of global shutter cameras. As a result, the wired system indicated an 8.91 μs mean triggering time difference between two cameras. Corresponding mean values for the four wireless triggering systems varied between 7.92 and 9.42 μs. Presented values include both camera-based and trigger-based desynchronization. Arduino-based triggering systems appeared to be feasible, and they have the potential to be extended to more complicated triggering systems.

  9. Wire chamber radiation detector with discharge control

    International Nuclear Information System (INIS)

    Perez-Mendez, V.; Mulera, T.A.

    1984-01-01

    A wire chamber radiation detector has spaced apart parallel electrodes and grids defining an ignition region in which charged particles or other ionizing radiations initiate brief localized avalanche discharges and defining an adjacent memory region in which sustained glow discharges are initiated by the primary discharges. Conductors of the grids at each side of the memory section extend in orthogonal directions enabling readout of the X-Y coordinates of locations at which charged particles were detected by sequentially transmitting pulses to the conductors of one grid while detecting transmissions of the pulses to the orthogonal conductors of the other grid through glow discharges. One of the grids bounding the memory region is defined by an array of conductive elements each of which is connected to the associated readout conductor through a separate resistance. The wire chamber avoids ambiguities and imprecisions in the readout of coordinates when large numbers of simultaneous or near simultaneous charged particles have been detected. Down time between detection periods and the generation of radio frequency noise are also reduced

  10. Humidity effects on wire insulation breakdown strength.

    Energy Technology Data Exchange (ETDEWEB)

    Appelhans, Leah

    2013-08-01

    Methods for the testing of the dielectric breakdown strength of insulation on metal wires under variable humidity conditions were developed. Two methods, an ASTM method and the twisted pair method, were compared to determine if the twisted pair method could be used for determination of breakdown strength under variable humidity conditions. It was concluded that, although there were small differences in outcomes between the two testing methods, the non-standard method (twisted pair) would be appropriate to use for further testing of the effects of humidity on breakdown performance. The dielectric breakdown strength of 34G copper wire insulated with double layer Poly-Thermaleze/Polyamide-imide insulation was measured using the twisted pair method under a variety of relative humidity (RH) conditions and exposure times. Humidity at 50% RH and below was not found to affect the dielectric breakdown strength. At 80% RH the dielectric breakdown strength was significantly diminished. No effect for exposure time up to 140 hours was observed at 50 or 80%RH.

  11. Sample of superconducting wiring from the LHC

    CERN Multimedia

    The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. Magnet coils are made of copper-clad niobium–titanium cables — each wire in the cable consists of 9’000 niobium–titanium filaments ten times finer than a hair. The cables carry up to 12’500 amps and must withstand enormous electromagnetic forces. At full field, the force on one metre of magnet is comparable to the weight of a jumbo jet. Coil winding requires great care to prevent movements as the field changes. Friction can create hot spots wh...

  12. Sample of superconducting wiring (Niobium Titanium)

    CERN Multimedia

    About NbTi cable: The cable consists of 36 strands of superconducting wire, each strand has a diameter of 0.825 mm and houses 6300 superconducting filaments of niobium-titanium (Nb-Ti, a superconducting alloy). Each filament has a diameter of about 0.006 mm, i.e. 10 times smaller than a typical human hair. The filaments are embedded in a high-purity copper matrix. Copper is a normal conducting material. The filaments are in the superconductive state when the temperature is below about -263ºC (10.15 K). When the filaments leave the superconductive state, the copper acts as conductor transports the electrical current. Each strand of The NbTi cable (at superconducting state) has a current density of up to above 2000 A/mm2 at 9 T and -271ºC (2.15 K). A cable transport a current of about 13000 A at 10 T and -271ºC (2.15 K). About LHC superconducting wiring: The high magnetic fields needed for the LHC can only be reached using superconductors. At very low temperatures, superconductors have no electrical resistan...

  13. Sample of superconducting wiring (Niobium Titanium)

    CERN Multimedia

    About NbTi cable: The cable consists of 36 strands of superconducting wire, each strand has a diameter of 0.825 mm and houses 6300 superconducting filaments of niobium-titanium (Nb-Ti, a superconducting alloy). Each filament has a diameter of about 0.006 mm, i.e. 10 times smaller than a typical human hair. The filaments are embedded in a high-purity copper matrix. Copper is a normal conducting material. The filaments are in the superconductive state when the temperature is below about -263ºC (10.15 K). When the filaments leave the superconductive state, the copper acts as conductor transports the electrical current. Each strand of The NbTi cable (at superconducting state) has a current density of up to above 2000 A/mm2 at 9 T and -271ºC (2.15 K). A cable transport a current of about 13000 A at 10 T and -271ºC (2.15 K). About LHC superconducting wiring: The high magnetic fields needed for the LHC can only be reached using superconductors. At very low temperatures, superconductors have no electrical resista...

  14. A New Superconducting Wire for Future Accelerators

    CERN Multimedia

    2006-01-01

    The CARE/NED project has developed a new superconducting wire that can achieve very high currents (1400 amps) at high magnetic fields (12 teslas). Cross-section of the CARE/NED wire produced by SMI. As we prepare to enter a new phase of particle physics with the LHC, technological development is a continuous process to ensure the demands of future research are met. The next generation of colliders and upgrades of the present ones will require significantly larger magnetic fields for bending and focusing the particle beams. NED (Next European Dipole) is one of the projects taking on this challenge to push technology beyond the present limit (see: More about NED). The magnets in the LHC rely on niobium titanium (NbTi) as the superconducting material, with a maximum magnetic field of 8 to 10T (tesla). In order to exceed this limitation, a different material together with the corresponding technology needs to be developed. NED is assessing the suitability of niobium tin (Nb3Sn), which has the potential to at le...

  15. VIC–CropSyst-v2: A regional-scale modeling platform to simulate the nexus of climate, hydrology, cropping systems, and human decisions

    Directory of Open Access Journals (Sweden)

    K. Malek

    2017-08-01

    Full Text Available Food supply is affected by a complex nexus of land, atmosphere, and human processes, including short- and long-term stressors (e.g., drought and climate change, respectively. A simulation platform that captures these complex elements can be used to inform policy and best management practices to promote sustainable agriculture. We have developed a tightly coupled framework using the macroscale variable infiltration capacity (VIC hydrologic model and the CropSyst agricultural model. A mechanistic irrigation module was also developed for inclusion in this framework. Because VIC–CropSyst combines two widely used and mechanistic models (for crop phenology, growth, management, and macroscale hydrology, it can provide realistic and hydrologically consistent simulations of water availability, crop water requirements for irrigation, and agricultural productivity for both irrigated and dryland systems. This allows VIC–CropSyst to provide managers and decision makers with reliable information on regional water stresses and their impacts on food production. Additionally, VIC–CropSyst is being used in conjunction with socioeconomic models, river system models, and atmospheric models to simulate feedback processes between regional water availability, agricultural water management decisions, and land–atmosphere interactions. The performance of VIC–CropSyst was evaluated on both regional (over the US Pacific Northwest and point scales. Point-scale evaluation involved using two flux tower sites located in agricultural fields in the US (Nebraska and Illinois. The agreement between recorded and simulated evapotranspiration (ET, applied irrigation water, soil moisture, leaf area index (LAI, and yield indicated that, although the model is intended to work on regional scales, it also captures field-scale processes in agricultural areas.

  16. VIC-CropSyst-v2: A regional-scale modeling platform to simulate the nexus of climate, hydrology, cropping systems, and human decisions

    Science.gov (United States)

    Malek, Keyvan; Stöckle, Claudio; Chinnayakanahalli, Kiran; Nelson, Roger; Liu, Mingliang; Rajagopalan, Kirti; Barik, Muhammad; Adam, Jennifer C.

    2017-08-01

    Food supply is affected by a complex nexus of land, atmosphere, and human processes, including short- and long-term stressors (e.g., drought and climate change, respectively). A simulation platform that captures these complex elements can be used to inform policy and best management practices to promote sustainable agriculture. We have developed a tightly coupled framework using the macroscale variable infiltration capacity (VIC) hydrologic model and the CropSyst agricultural model. A mechanistic irrigation module was also developed for inclusion in this framework. Because VIC-CropSyst combines two widely used and mechanistic models (for crop phenology, growth, management, and macroscale hydrology), it can provide realistic and hydrologically consistent simulations of water availability, crop water requirements for irrigation, and agricultural productivity for both irrigated and dryland systems. This allows VIC-CropSyst to provide managers and decision makers with reliable information on regional water stresses and their impacts on food production. Additionally, VIC-CropSyst is being used in conjunction with socioeconomic models, river system models, and atmospheric models to simulate feedback processes between regional water availability, agricultural water management decisions, and land-atmosphere interactions. The performance of VIC-CropSyst was evaluated on both regional (over the US Pacific Northwest) and point scales. Point-scale evaluation involved using two flux tower sites located in agricultural fields in the US (Nebraska and Illinois). The agreement between recorded and simulated evapotranspiration (ET), applied irrigation water, soil moisture, leaf area index (LAI), and yield indicated that, although the model is intended to work on regional scales, it also captures field-scale processes in agricultural areas.

  17. Wire Position Monitoring with FPGA based Electronics

    International Nuclear Information System (INIS)

    Eddy, N.; Lysenko, O.

    2009-01-01

    This fall the first Tesla-style cryomodule cooldown test is being performed at Fermilab. Instrumentation department is preparing the electronics to handle the data from a set of wire position monitors (WPMs). For simulation purposes a prototype pipe with a WMP has been developed and built. The system is based on the measurement of signals induced in pickups by 320 MHz signal carried by a wire through the WPM. The wire is stretched along the pipe with a tensioning load of 9.07 kg. The WPM consists of four 50 (Omega) striplines spaced 90 o apart. FPGA based digitizer scans the WPM and transmits the data to a PC via VME interface. The data acquisition is based on the PC running LabView. In order to increase the accuracy and convenience of the measurements some modifications were required. The first is implementation of an average and decimation filter algorithm in the integrator operation in the FPGA. The second is the development of alternative tool for WPM measurements in the PC. The paper describes how these modifications were performed and test results of a new design. The last cryomodule generation has a single chain of seven WPMs (placed in critical positions: at each end, at the three posts and between the posts) to monitor a cold mass displacement during cooldown. The system was developed in Italy in collaboration with DESY. Similar developments have taken place at Fermilab in the frame of cryomodules construction for SCRF research. This fall preliminary cryomodule cooldown test is being performed. In order to prepare an appropriate electronic system for the test a prototype pipe with a WMP has been developed and built, figure 1. The system is based on the measurement of signals induced in pickups by 320 MHz signal carried by a wire through the WPM. The 0.5 mm diameter Cu wire is stretched along the pipe with a tensioning load of 9.07 kg and has a length of 1.1 m. The WPM consists of four 50 (Omega) striplines spaced 90 o apart. An FPGA based digitizer

  18. Temperature Diffusion Distribution of Electric Wire Deteriorated by Overcurrent

    Science.gov (United States)

    Choi, Chung-Seog; Kim, Hyang-Kon; Kim, Dong-Woo; Lee, Ki-Yeon

    This study presents thermal diffusion distribution of the electric wires when overcurrent is supplied to copper wires. And then, this study intends to provide a basis of knowledge for analyzing the causes of electric accidents through hybrid technology. In the thermal image distribution analysis of the electric wire to which fusing current was supplied, it was found that less heat was accumulated in the thin wires because of easier heat dispersion, while more heat was accumulated in the thicker wires. The 3-dimensional thermal image analysis showed that heat distribution was concentrated at the center of the wire and the inclination of heat distribution was steep in the thicker wires. When 81A was supplied to 1.6mm copper wire for 500 seconds, the surface temperature of wire was maximum 46.68°C and minimum 30.87°C. It revealed the initial characteristics of insulation deterioration that generates white smoke without external deformation. In the analysis with stereoscopic microscope, the surface turned dark brown and rough with the increase of fusing current. Also, it was known that exfoliation occurred when wire melted down with 2 times the fusing current. With the increase of current, we found the number of primary arms of the dendrite structure to be increased and those of the secondary and tertiary arms to be decreased. Also, when the overcurrent reached twice the fusing current, it was found that columnar composition, observed in the cross sectional structure of molten wire, appeared and formed regular directivity. As described above, we could present the burning pattern and change in characteristics of insulation and conductor quantitatively. And we could not only minimize the analysis error by combining the information but also present the scientific basis in the analysis of causes of electric accidents, mediation of disputes on product liability concerning the electric products.

  19. Ultrasound-guided wire localization of lesions detected on ...

    African Journals Online (AJOL)

    Background: Wire localization for planned surgical treatment in the management of breast cancer is underutilized in our environment. The objective of this study is to assess the role of ultrasound-guided wire localization of breast masses detected on screening mammography and its impact on biopsy and breast ...

  20. PRODUCTION OF ELECTROTECHNICAL WIRE OF SCRAP AND COPPER WASTES

    Directory of Open Access Journals (Sweden)

    I. P. Volchok

    2006-01-01

    Full Text Available Chemical composition, structure and properties of copper upon base steps of wire production technology (melting of anode copper with using of scrap and waste, electrolitical refining, producing of rod by continuous casting, manufacture of electrotechnical wire and fibres is described.

  1. Liquid Metal Machine Triggered Violin-Like Wire Oscillator.

    Science.gov (United States)

    Yuan, Bin; Wang, Lei; Yang, Xiaohu; Ding, Yujie; Tan, Sicong; Yi, Liting; He, Zhizhu; Liu, Jing

    2016-10-01

    The first ever oscillation phenomenon of a copper wire embraced inside a self-powered liquid metal machine is discovered. When contacting a copper wire to liquid metal machine, it would be swallowed inside and then reciprocally moves back and forth, just like a violin bow. Such oscillation could be easily regulated by touching a steel needle on the liquid metal surface.

  2. Test plan for Enraf Series 854 level gauge wire testing

    International Nuclear Information System (INIS)

    Barnes, G.A.

    1994-01-01

    An Enraf Series 854 level gauge was installed on tank 241-S-106 during the first week of June 1994. On August 11, 1994, the gauge's stainless steel measuring wire broke. After examination and laboratory analysis, it was determined that the wire broke due to severe chloride ion corrosion. It is suspected that the chloride ion contamination came from the radiation induced breakdown of the polyvinyl chloride (PVC) riser liner. It is well documented that the breakdown of PVC due to radiation produces chloride containing compounds. This document provides a qualification test plan to remove and have analyzed the wire in all of the Enraf Series 854 that have been installed to date. These tests will confirm the presence or absence of chloride ions in the PVC liners and/or on the Enraf measuring wires installed in the tanks. This test will involve removing the 316 stainless steel wire drums from all of the existing Enraf Series 854 level gauges that have been installed. New 316 stainless steel wire drums shall be installed into the gauges and the gauges will be placed back into service. The wire that is removed from the gauges shall be sent to the 222-S Lab or the Pacific Northwest Laboratory (PNL) for analysis. Additional wire replacements will occur at intervals as determined necessary by the results of the laboratory analyses

  3. Wire winding increases lifetime of oxide coated cathodes

    Science.gov (United States)

    Kerslake, W.; Vargo, D.

    1965-01-01

    Refractory-metal heater base wound with a thin refractory metal wire increases the longevity of oxide-coated cathodes. The wire-wound unit is impregnated with the required thickness of metal oxide. This cathode is useful in magnetohydrodynamic systems and in electron tubes.

  4. Notched K-wire for low thermal damage bone drilling.

    Science.gov (United States)

    Liu, Yao; Belmont, Barry; Wang, Yiwen; Tai, Bruce; Holmes, James; Shih, Albert

    2017-07-01

    The Kirschner wire (K-wire) is a common bone drilling tool in orthopedic surgery to affix fractured bone. Significant heat is produced due to both the cutting and the friction between the K-wire and the bone debris during drilling. Such heat can result in high temperatures, leading to osteonecrosis and other secondary injuries. To reduce thermal injury and other high-temperature associated complications, a new K-wire design with three notches along the three-plane trocar tip fabricated using a thin micro-saw tool is studied. These notches evacuate bone debris and reduce the clogging and heat generation during bone drilling. A set of four K-wires, one without notches and three notched, with depths of 0.5, 0.75, and 1mm, are evaluated. Bone drilling experiments conducted on bovine cortical bone show that notched K-wires could effectively decrease the temperature, thrust force, and torque during bone drilling. K-wires with notches 1mm deep reduced the thrust force and torque by approximately 30%, reduced peak temperatures by 43%, and eliminated blackened burn marks in bone. This study demonstrates that a simple modification of the tip of K-wires can effectively reduce bone temperatures during drilling. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  5. SpaceWire: IP, Components, Development Support and Test Equipment

    Science.gov (United States)

    Parkes, S.; McClements, C.; Mills, S.; Martin, I.

    SpaceWire is a communications network for use onboard spacecraft. It is designed to connect high data-rate sensors, large solid-state memories, processing units and the downlink telemetry subsystem providing an integrated data-handling network. SpaceWire links are serial, high-speed (2 Mbits/sec to 400 Mbits/sec), bi-directional, full-duplex, pointto- point data links which connect together SpaceWire equipment. Application information is sent along a SpaceWire link in discrete packets. Control and time information can also be sent along SpaceWire links. SpaceWire is defined in the ECSS-E50-12A standard [1]. With the adoption of SpaceWire on many space missions the ready availability of intellectual property (IP) cores, components, software drivers, development support, and test equipment becomes a major issue for those developing satellites and their electronic subsystems. This paper describes the work being done at the University of Dundee and STAR-Dundee Ltd with ESA, BNSC and internal funding to make these essential items available. STAR-Dundee is a spin-out company of the University of Dundee set up specifically to support users of SpaceWire.

  6. 29 CFR 1910.304 - Wiring design and protection.

    Science.gov (United States)

    2010-07-01

    ... contacts effectively grounded except for receptacles mounted on portable and vehicle-mounted generators in... types of current (ac or dc) on the same premises shall be of such design that the attachment plugs used... premises wiring shall be grounded as follows: (i) All 3-wire dc systems shall have their neutral conductor...

  7. Variations in the Magnetic Torque Acting on a Wire

    Science.gov (United States)

    Bonati, Claudio

    2012-01-01

    The relation M = [mu] x B is presented in all elementary courses on electromagnetism, but it is usually given just for the simple case of a rectangular wire. We will present a completely general but elementary proof of this relation together with two more advanced proof methods. We will then provide some extensions: non-closed wires and…

  8. 26 CFR 49.4252-7 - Wire and equipment service.

    Science.gov (United States)

    2010-04-01

    ... of illegal entry, fire, leakage, etc. (2) Wire lines or channels furnished between a point of origin... subscriber may obtain information as to a given condition at the remote point, such as water level, water pressure, gas pressure, etc. (4) Remote control wire lines or channels furnished between a remote point and...

  9. Loss of Guide Wire: A Lesson Learnt Review of Literature

    African Journals Online (AJOL)

    or sometimes with delay.[2-5] Here, we elucidate a case of retained guide wire during cannulation of the right external iliac vein, which was ... [3,5] If this rule is followed, the guide wire cannot get lost. The diagnosis is very simple, which is often established incidentally during routine radiographic exams.[4,5]. We report the ...

  10. Optimum driving of magnetostrictive amorphous wire micro-motor

    International Nuclear Information System (INIS)

    Takezawa, Masaaki; Ishizaki, Yuichi; Honda, Takashi; Yamasaki, Jiro

    2004-01-01

    Characteristics of a magnetostrictive vibration micro-motor were investigated in relation to a supporting position of a magnetostrictive amorphous wire for optimization of the motor. It was found that a vibration of the wire resembled a vibration mode of both ends free and a maximum rotational speed was obtained by supporting the nodes of vibration

  11. Recent development of drastically innovative BSCCO wire (DI-BISCCO)

    International Nuclear Information System (INIS)

    Kikuchi, M.; Kato, T.; Ohkura, K.; Ayai, N.; Fujikami, J.; Fujino, K.; Kobayashi, S.; Ueno, E.; Yamazaki, K.; Yamade, S.; Hayashi, K.; Sato, K.; Nagai, T.; Matsui, Y.

    2006-01-01

    Up to this day, Ag-sheathed Bi2223 superconducting wires have been widely investigated and the long wires about 1000 m have been produced by using powder-in-tube (PIT) method on a commercial basis in the various facilities or companies. Although the wires are used for some applications such as HTS cables, magnets, motor and so on, the Bi2223 wires not only require much more improvements of the superconducting properties such as critical current, mechanical properties, but also longer and more uniform wires. Recently, the performances of Bi2223 wires have been drastically improved by using Controlled Over Pressure (CT-OP) sintering process. CT-OP process increased critical current (I c ) by more than 60% at 77 K and self field and improved the mechanical strength by more than 70%. The maximum I c was increased up to 166 A. These drastic improvements were caused by the higher density of Bi2223 filament up to almost 100% and better connectivity of the Bi2223 grains. The dense structure of the Bi2223 filaments prevents the ballooning phenomenon which is caused by the gasification of the trapped liquid nitrogen during temperature rise. Additionally, higher uniformity and higher production yield of long length wire were also achieved by exterminating defects during sintering. These high performance levels in CT-OP wires have contributed commercial level applications. We call as Drastically Innovative BSCCO (DI-BSCCO)

  12. Analytical guide wire motion algorithm for simulation of endovascular interventions

    NARCIS (Netherlands)

    Konings, M. K.; van de Kraats, E. B.; Alderliesten, T.; Niessen, W. J.

    2003-01-01

    Performing minimally invasive vascular interventions requires proper training, as a guide wire needs to be manipulated, by the tail, under fluoroscopic guidance. To provide a training environment, the motion of the guide wire inside the human vasculature can be simulated by computer. Such a

  13. Wire bond degradation under thermo- and pure mechanical loading

    DEFF Research Database (Denmark)

    Pedersen, Kristian Bonderup; Nielsen, Dennis Achton; Czerny, Bernhard

    2017-01-01

    This paper presents a fundamental study on degradation of heavy Al bond wires typically used in high power modules. Customized samples are designed to only consist of Al bond wires on standard Si diodes. These samples are subjected to pure mechanical and passive thermal cycling to investigate...

  14. Safe corridors for K-wiring in phalangeal fractures

    Directory of Open Access Journals (Sweden)

    C Rex

    2015-01-01

    Conclusion: K-wiring through the safe corridor has proved to yield the best clinical results because of least tethering of soft tissues as evidenced by performing "on-table active finger movement test" at the time of surgery. We strongly recommend K-wiring through safe portals in all phalangeal fractures.

  15. Water-cooled grid ''wires'' for direct converters

    International Nuclear Information System (INIS)

    Schwer, C.J.

    1976-01-01

    A study was conducted to determine the feasibility of internal convective cooling of grid ''wires'' for direct converters. Detailed computer calculations reveal that the use of small diameter water cooled tubes as grid ''wires'' is feasible for a considerable range of lengths and thermal fluxes

  16. 46 CFR 183.340 - Cable and wiring requirements.

    Science.gov (United States)

    2010-10-01

    ... a manner as to avoid chafing and other damage. The use of plastic tie wraps must be limited to... requirements. (a) If individual wires, rather than cable, are used in systems greater than 50 volts, the wire... current carrying capacity for the circuit in which they are used; (2) Be installed in a manner to avoid or...

  17. 46 CFR 120.340 - Cable and wiring requirements.

    Science.gov (United States)

    2010-10-01

    ... chafing and other damage. The use of plastic tie wraps must be limited to bundling or retention of... wires, rather than cables, are used in systems greater than 50 volts, the wire must be in conduit. (b... for the circuit in which they are used; (2) Be installed in a manner to avoid or reduce interference...

  18. Exciton dephasing in ZnSe quantum wires

    DEFF Research Database (Denmark)

    Wagner, Hans Peter; Langbein, Wolfgang Werner; Hvam, Jørn Märcher

    1998-01-01

    The homogeneous linewidths of excitons in wet-etched ZnSe quantum wires of lateral sizes down to 23 nm are studied by transient four-wave mixing. The low-density dephasing time is found to increase with decreasing wire width. This is attributed mainly to a reduction of electron-exciton scattering...

  19. 78 FR 7452 - Steel Wire Garment Hangers From Vietnam; Determinations

    Science.gov (United States)

    2013-02-01

    ...), that an industry in the United States is materially injured by reason of imports of steel wire garment... Garment Hangers From Vietnam; Determinations On the basis of the record \\1\\ developed in the subject... duty orders on steel wire garment hangers from Vietnam. Background The Commission instituted these...

  20. Donor-akceptorové systémy jako materiály pro molekulární elektroniku

    Czech Academy of Sciences Publication Activity Database

    Dekoj, Václav; Bělohradský, Martin; Lipnická, Šárka; Starý, Ivo

    2008-01-01

    Roč. 102, č. 5 (2008), s. 369-369 ISSN 0009-2770. [Mezioborové setkání mladých biologů, biochemiků a chemiků. Konference Sigma-Aldrich /8./. 10.06.2008-13.06.2008, Devět skal - Žďárské vrchy] Institutional research plan: CEZ:AV0Z40550506 Keywords : oligophenylenacetylenes * TTF * molecular wires Subject RIV: CC - Organic Chemistry