WorldWideScience

Sample records for wireless telemetry electronic

  1. High-Performance Wireless Telemetry

    Science.gov (United States)

    Griebeler, Elmer; Nawash, Nuha; Buckley, James

    2011-01-01

    Prior technology for machinery data acquisition used slip rings, FM radio communication, or non-real-time digital communication. Slip rings are often noisy, require much space that may not be available, and require access to the shaft, which may not be possible. FM radio is not accurate or stable, and is limited in the number of channels, often with channel crosstalk, and intermittent as the shaft rotates. Non-real-time digital communication is very popular, but complex, with long development time, and objections from users who need continuous waveforms from many channels. This innovation extends the amount of information conveyed from a rotating machine to a data acquisition system while keeping the development time short and keeping the rotating electronics simple, compact, stable, and rugged. The data are all real time. The product of the number of channels, times the bit resolution, times the update rate, gives a data rate higher than available by older methods. The telemetry system consists of a data-receiving rack that supplies magnetically coupled power to a rotating instrument amplifier ring in the machine being monitored. The ring digitizes the data and magnetically couples the data back to the rack, where it is made available. The transformer is generally a ring positioned around the axis of rotation with one side of the transformer free to rotate and the other side held stationary. The windings are laid in the ring; this gives the data immunity to any rotation that may occur. A medium-frequency sine-wave power source in a rack supplies power through a cable to a rotating ring transformer that passes the power on to a rotating set of electronics. The electronics power a set of up to 40 sensors and provides instrument amplifiers for the sensors. The outputs from the amplifiers are filtered and multiplexed into a serial ADC. The output from the ADC is connected to another rotating ring transformer that conveys the serial data from the rotating section to

  2. Flexible network wireless transceiver and flexible network telemetry transceiver

    Science.gov (United States)

    Brown, Kenneth D.

    2008-08-05

    A transceiver for facilitating two-way wireless communication between a baseband application and other nodes in a wireless network, wherein the transceiver provides baseband communication networking and necessary configuration and control functions along with transmitter, receiver, and antenna functions to enable the wireless communication. More specifically, the transceiver provides a long-range wireless duplex communication node or channel between the baseband application, which is associated with a mobile or fixed space, air, water, or ground vehicle or other platform, and other nodes in the wireless network or grid. The transceiver broadly comprises a communication processor; a flexible telemetry transceiver including a receiver and a transmitter; a power conversion and regulation mechanism; a diplexer; and a phased array antenna system, wherein these various components and certain subcomponents thereof may be separately enclosed and distributable relative to the other components and subcomponents.

  3. OIT Wireless Telemetry for Industrial Applications

    Energy Technology Data Exchange (ETDEWEB)

    Manges, WW

    2002-09-03

    The need for advanced wireless technology has been identified in the National Research Council publication (1) ''Manufacturing Process Controls for the Industries of the Future as a Critical Technology for the Future''. The deployment challenges to be overcome in order for wireless to be a viable option include: (1) eliminating interference (assuring reliable communications); (2) easing the deployment of intelligent, wireless sensors; (3) developing reliable networks (robust architectures); (4) developing remote power (long-lasting and reliable); and (5) developing standardized communication protocols. This project demonstrated the feasibility of robust wireless sensor networks that could meet these requirements for the harsh environments common to the DOE/OIT Industries of the Future. It resulted in a wireless test bed that was demonstrated in a paper mill and a steel plant. The test bed illustrated key protocols and components that would be required in a real-life, wireless network. The technologies for low power connectivity developed and demonstrated at the plant eased fears that the radios would interfere with existing control equipment. The same direct sequence, spread spectrum (DSSS) technology that helped assure the reliability of the connection also demonstrated that wireless communication was feasible in these plants without boosting the transmitted power to dangerous levels. Our experience and research have indicated that two key parameters are of ultimate importance: (1) reliability and (2) inter-system compatibility. Reliability is the key to immediate acceptance among industrial users. The importance cannot be overstated, because users will not tolerate an unreliable information network. A longer term issue that is at least as important as the reliability of a single system is the inter-system compatibility between these wireless sensor networks and other wireless systems that are part of our industries. In the long run, the

  4. Wireless Biological Electronic Sensors.

    Science.gov (United States)

    Cui, Yue

    2017-10-09

    The development of wireless biological electronic sensors could open up significant advances for both fundamental studies and practical applications in a variety of areas, including medical diagnosis, environmental monitoring, and defense applications. One of the major challenges in the development of wireless bioelectronic sensors is the successful integration of biosensing units and wireless signal transducers. In recent years, there are a few types of wireless communication systems that have been integrated with biosensing systems to construct wireless bioelectronic sensors. To successfully construct wireless biological electronic sensors, there are several interesting questions: What types of biosensing transducers can be used in wireless bioelectronic sensors? What types of wireless systems can be integrated with biosensing transducers to construct wireless bioelectronic sensors? How are the electrical sensing signals generated and transmitted? This review will highlight the early attempts to address these questions in the development of wireless biological electronic sensors.

  5. MEMS sensors and wireless telemetry for distributed systems

    Energy Technology Data Exchange (ETDEWEB)

    Britton, C.L. Jr.; Warmack, R.J.; Smith, S.F. [and others

    1998-02-01

    Selectively coated cantilevers are being developed at ORNL for chemical and biological sensing. The sensitivity can exceed that of other electro-mechanical devices as parts-per-trillion detection can be demonstrated for certain species. The authors are now proceeding to develop systems that employ electrically readable microcantilevers in a standard MEMS process and standard CMOS processes. One of their primary areas of interest is chemical sensing for environmental applications. Towards this end, they are presently developing electronic readout of a mercury-sensitive coated cantilever. In order to field arrays of distributed sensors, a wireless network for data reporting is needed. For this, the authors are developing on-chip spread-spectrum encoding and modulation circuitry to improve the robustness and security of sensor data in typical interference- and multipath-impaired environments. They have also provided for a selection of distinct spreading codes to serve groups of sensors in a common environment by the application of code-division multiple-access techniques. Most of the RF circuitry they have designed and fabricated in 0.5 {micro}m CMOS has been tested and verified operational to above 1 GHz. The initial intended operation is for use in the 915 MHz Industrial, Scientific, and Medical (ISM) band. This paper presents measured data on the microcantilever-based mercury detector. They also present design data and measurements of the RF telemetry chip.

  6. Micropower circuits for bidirectional wireless telemetry in neural recording applications.

    Science.gov (United States)

    Neihart, Nathan M; Harrison, Reid R

    2005-11-01

    State-of-the art neural recording systems require electronics allowing for transcutaneous, bidirectional data transfer. As these circuits will be implanted near the brain, they must be small and low power. We have developed micropower integrated circuits for recovering clock and data signals over a transcutaneous power link. The data recovery circuit produces a digital data signal from an ac power waveform that has been amplitude modulated. We have also developed an FM transmitter with the lowest power dissipation reported for biosignal telemetry. The FM transmitter consists of a low-noise biopotential amplifier and a voltage controlled oscillator used to transmit amplified neural signals at a frequency near 433 MHz. All circuits were fabricated in a standard 0.5-microm CMOS VLSI process. The resulting chip is powered through a wireless inductive link. The power consumption of the clock and data recovery circuits is measured to be 129 microW; the power consumption of the transmitter is measured to be 465 microW when using an external surface mount inductor. Using a parasitic antenna less than 2 mm long, a received power level was measured to be -59.73 dBm at a distance of one meter.

  7. Wireless gigabit data telemetry for large-scale neural recording.

    Science.gov (United States)

    Kuan, Yen-Cheng; Lo, Yi-Kai; Kim, Yanghyo; Chang, Mau-Chung Frank; Liu, Wentai

    2015-05-01

    Implantable wireless neural recording from a large ensemble of simultaneously acting neurons is a critical component to thoroughly investigate neural interactions and brain dynamics from freely moving animals. Recent researches have shown the feasibility of simultaneously recording from hundreds of neurons and suggested that the ability of recording a larger number of neurons results in better signal quality. This massive recording inevitably demands a large amount of data transfer. For example, recording 2000 neurons while keeping the signal fidelity ( > 12 bit, > 40 KS/s per neuron) needs approximately a 1-Gb/s data link. Designing a wireless data telemetry system to support such (or higher) data rate while aiming to lower the power consumption of an implantable device imposes a grand challenge on neuroscience community. In this paper, we present a wireless gigabit data telemetry for future large-scale neural recording interface. This telemetry comprises of a pair of low-power gigabit transmitter and receiver operating at 60 GHz, and establishes a short-distance wireless link to transfer the massive amount of neural signals outward from the implanted device. The transmission distance of the received neural signal can be further extended by an externally rendezvous wireless transceiver, which is less power/heat-constraint since it is not at the immediate proximity of the cortex and its radiated signal is not seriously attenuated by the lossy tissue. The gigabit data link has been demonstrated to achieve a high data rate of 6 Gb/s with a bit-error-rate of 10(-12) at a transmission distance of 6 mm, an applicable separation between transmitter and receiver. This high data rate is able to support thousands of recording channels while ensuring a low energy cost per bit of 2.08 pJ/b.

  8. Prototype Sistem Multi-Telemetri Wireless untuk Mengukur Suhu Udara Berbasis Mikrokontroler ESP8266 pada Greenhouse

    OpenAIRE

    Hanum Shirotu Nida

    2017-01-01

    Telemetri wireless adalah proses pengukuran parameter suatu obyek yang hasil pengukurannya dikirimkan ke tempat lain melalui proses pengiriman data tanpa menggunakan kabel (wireless), sedangkan multi telemetri adalah gabungan dari beberapa telemeteri itu sendiri. Penelitian ini merancang prototype sistem multi-telemetri wireless untuk mengukur suhu udara dan kelembaban udara pada greenhouse dengan menggunakan sensor DHT11 dan data hasil dari pembacaan sensor dikirim dengan menggunakan modul W...

  9. Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

    Science.gov (United States)

    Jia, Zhiwei; Yan, Guozheng; Zhu, Bingquan

    2015-04-01

    An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.

  10. Design of a telemetry system based on wireless power transmission for physiological parameter monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Jia, Zhiwei, E-mail: jiayege@hotmail.com [College of Electrical and Information Engineering, Changsha University of Science and Technology, Changsha (China); Yan, Guozheng; Zhu, Bingquan [820 Institute, School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai (China)

    2015-04-15

    An implanted telemetry system for experimental animals with or without anaesthesia can be used to continuously monitor physiological parameters. This system is significant not only in the study of organisms but also in the evaluation of drug efficacy, artificial organs, and auxiliary devices. The system is composed of a miniature electronic capsule, a wireless power transmission module, a data-recording device, and a processing module. An electrocardiograph, a temperature sensor, and a pressure sensor are integrated in the miniature electronic capsule, in which the signals are transmitted in vitro by wireless communication after filtering, amplification, and A/D sampling. To overcome the power shortage of batteries, a wireless power transmission module based on electromagnetic induction was designed. The transmitting coil of a rectangular-section solenoid and a 3D receiving coil are proposed according to stability and safety constraints. Experiments show that at least 150 mW of power could pick up on the load in a volume of Φ10.5 mm × 11 mm, with a transmission efficiency of 2.56%. Vivisection experiments verified the feasibility of the integrated radio-telemetry system.

  11. Prototype Sistem Multi-Telemetri Wireless untuk Mengukur Suhu Udara Berbasis Mikrokontroler ESP8266 pada Greenhouse

    Directory of Open Access Journals (Sweden)

    Hanum Shirotu Nida

    2017-07-01

    Full Text Available Telemetri wireless adalah proses pengukuran parameter suatu obyek yang hasil pengukurannya dikirimkan ke tempat lain melalui proses pengiriman data tanpa menggunakan kabel (wireless, sedangkan multi telemetri adalah gabungan dari beberapa telemeteri itu sendiri. Penelitian ini merancang prototype sistem multi-telemetri wireless untuk mengukur suhu udara dan kelembaban udara pada greenhouse dengan menggunakan sensor DHT11 dan data hasil dari pembacaan sensor dikirim dengan menggunakan modul WiFi ESP8266 ke server dengan menggunakan protokol HTTP. Dalam penelitian ini diuji nilai sensor DHT11, heap memory ESP8266, jarak atau jangkauan ESP8266, uji coba data missing handling dan kestabilan jaringan. Berdasarkan hasil pengujian diketahui bahwa sensor DHT11 memiliki rata-rata kesalahan ukur suhu 0.92 oC dan kelembaban 3.1%. Modul WiFi ESP8266 mampu menyimpan dan mengirim buffer hingga 100 data dan dapat melakukan pengiriman dalam jangkauan 50 meter. Data missing handling memanfaatkan buffer untuk menyimpan data selama server sedang tidak dapat diakses oleh sensor node agar data tidak hillang. Kestabilan pengiriman data atau koneksi sensor node dengan server dipengaruhi oleh jumlah access point yang sedang berkomunikasi disekitar access point server dengan menggunakan channel yang sama.

  12. Electronics and Telemetry Engineering and Test Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Electronics Laboratory is a fully equipped facility providing the capability to support electronic product development from highly complex weapon system sensors,...

  13. Rodent scope: a user-configurable digital wireless telemetry system for freely behaving animals.

    Science.gov (United States)

    Ball, David; Kliese, Russell; Windels, Francois; Nolan, Christopher; Stratton, Peter; Sah, Pankaj; Wiles, Janet

    2014-01-01

    This paper describes the design and implementation of a wireless neural telemetry system that enables new experimental paradigms, such as neural recordings during rodent navigation in large outdoor environments. RoSco, short for Rodent Scope, is a small lightweight user-configurable module suitable for digital wireless recording from freely behaving small animals. Due to the digital transmission technology, RoSco has advantages over most other wireless modules of noise immunity and online user-configurable settings. RoSco digitally transmits entire neural waveforms for 14 of 16 channels at 20 kHz with 8-bit encoding which are streamed to the PC as standard USB audio packets. Up to 31 RoSco wireless modules can coexist in the same environment on non-overlapping independent channels. The design has spatial diversity reception via two antennas, which makes wireless communication resilient to fading and obstacles. In comparison with most existing wireless systems, this system has online user-selectable independent gain control of each channel in 8 factors from 500 to 32,000 times, two selectable ground references from a subset of channels, selectable channel grounding to disable noisy electrodes, and selectable bandwidth suitable for action potentials (300 Hz-3 kHz) and low frequency field potentials (4 Hz-3 kHz). Indoor and outdoor recordings taken from freely behaving rodents are shown to be comparable to a commercial wired system in sorting for neural populations. The module has low input referred noise, battery life of 1.5 hours and transmission losses of 0.1% up to a range of 10 m.

  14. Development of a methodology to measure the effect of ergot alkaloids on forestomach motility using real-time wireless telemetry

    Science.gov (United States)

    The objectives of these experiments were to characterize rumen motility patterns of cattle fed once daily using a real-time wireless telemetry system, determine when to measure rumen motility with this system, and determine the effect of ruminal dosing of ergot alkaloids on rumen motility. Ruminally...

  15. Foundations of wireless and electronics

    CERN Document Server

    Scroggie, M G

    1984-01-01

    Foundations of Wireless and Electronics, 10th Edition covers the cathode-ray and microwave tubes; modern pulse methods; f.m. detectors; basic processes of transmission; and reception, computers, and non-sinusoidal signal amplification. The book starts by giving a general overview of a complete electronic system, electricity and circuits, capacitance, and inductance. The text also discusses alternating currents (a.c.), including the frequency and phase of a.c.; the capacitance and inductance in a.c. circuits; and the capacitance and inductance in a series. Diodes, triode, transistor equivalent

  16. A Wireless FSCV Monitoring IC With Analog Background Subtraction and UWB Telemetry.

    Science.gov (United States)

    Dorta-Quiñones, Carlos I; Wang, Xiao Y; Dokania, Rajeev K; Gailey, Alycia; Lindau, Manfred; Apsel, Alyssa B

    2016-04-01

    A 30-μW wireless fast-scan cyclic voltammetry monitoring integrated circuit for ultra-wideband (UWB) transmission of dopamine release events in freely-behaving small animals is presented. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus standard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission for low data rates. The 1.5- mm(2) chip, which was fabricated in 65-nm CMOS technology, consists of a low-noise potentiostat frontend, a two-step analog-to-digital converter (ADC), and an impulse-radio UWB transmitter (TX). The duty-cycled frontend and ADC/UWB-TX blocks draw 4 μA and 15 μA from 3-V and 1.2-V supplies, respectively. The chip achieves an input-referred current noise of 92 pA(rms) and an input current range of ±430 nA at a conversion rate of 10 kHz. The packaged device operates from a 3-V coin-cell battery, measures 4.7 × 1.9 cm(2), weighs 4.3 g (including the battery and antenna), and can be carried by small animals. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 1 μM with a carbon-fiber microelectrode (CFM) using 300-V/s FSCV.

  17. A Wireless FSCV Monitoring IC with Analog Background Subtraction and UWB Telemetry

    Science.gov (United States)

    Dorta-Quiñones, Carlos I.; Wang, Xiao Y.; Dokania, Rajeev K.; Gailey, Alycia; Lindau, Manfred; Apsel, Alyssa B.

    2015-01-01

    A 30-μW wireless fast-scan cyclic voltammetry monitoring integrated circuit for ultra-wideband (UWB) transmission of dopamine release events in freely-behaving small animals is presented. On-chip integration of analog background subtraction and UWB telemetry yields a 32-fold increase in resolution versus standard Nyquist-rate conversion alone, near a four-fold decrease in the volume of uplink data versus single-bit, third-order, delta-sigma modulation, and more than a 20-fold reduction in transmit power versus narrowband transmission for low data rates. The 1.5-mm2 chip, which was fabricated in 65-nm CMOS technology, consists of a low-noise potentiostat frontend, a two-step analog-to-digital converter (ADC), and an impulse-radio UWB transmitter (TX). The duty-cycled frontend and ADC/UWB-TX blocks draw 4 μA and 15 μA from 3-V and 1.2-V supplies, respectively. The chip achieves an input-referred current noise of 92 pArms and an input current range of ±430 nA at a conversion rate of 10 kHz. The packaged device operates from a 3-V coin-cell battery, measures 4.7 × 1.9 cm2, weighs 4.3 g (including the battery and antenna), and can be carried by small animals. The system was validated by wirelessly recording flow-injection of dopamine with concentrations in the range of 250 nM to 1 μM with a carbon-fiber microelectrode (CFM) using 300-V/s FSCV. PMID:26057983

  18. ELECTRICAL AND ELECTRONIC INDUSTRIAL CONTROL, STATIC CONTROL SERIES. REMOTE CONTROL BY INDUSTRIAL TELEMETRY. UNIT 9C.

    Science.gov (United States)

    Texas Education Agency, Austin. Industrial Education Div.

    THIS SELF-INSTRUCTIONAL PROGRAMED TEXT IS FOR STUDENT USE IN STUDYING INDUSTRIAL TELEMETRY CONTROL SYSTEMS IN ELECTRICAL-ELECTRONIC PROGRAMS. IT WAS DEVELOPED BY AN INSTRUCTIONAL MATERIALS SPECIALIST AND ADVISERS AND TESTED BY STUDENT USE. THE MATERIAL IS DIVIDED INTO FUNDAMENTAL IDEAS AND LANGUAGE OF INDUSTRIAL TELEMETRY AND THE LOGIC OF THE…

  19. In Vivo Characterization of a Wireless Telemetry Module for a Capsule Endoscopy System Utilizing a Conformal Antenna.

    Science.gov (United States)

    Faerber, Julia; Cummins, Gerard; Pavuluri, Sumanth Kumar; Record, Paul; Rodriguez, Adrian R Ayastuy; Lay, Holly S; McPhillips, Rachael; Cox, Benjamin F; Connor, Ciaran; Gregson, Rachael; Clutton, Richard Eddie; Khan, Sadeque Reza; Cochran, Sandy; Desmulliez, Marc P Y

    2018-02-01

    This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of -10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10 -3 packet error rate and 10 -5 bit error rate and no temperature increase of the tissue according to IEEE standards.

  20. A Differential Pressure Instrument with Wireless Telemetry for In-Situ Measurement of Fluid Flow across Sediment-Water Boundaries

    Directory of Open Access Journals (Sweden)

    Alan T. Gardner

    2009-01-01

    Full Text Available An instrument has been built to carry out continuous in-situ measurement of small differences in water pressure, conductivity and temperature, in natural surface water and groundwater systems. A low-cost data telemetry system provides data on shore in real time if desired. The immediate purpose of measurements by this device is to continuously infer fluxes of water across the sediment-water interface in a complex estuarine system; however, direct application to assessment of sediment-water fluxes in rivers, lakes, and other systems is also possible. Key objectives of the design include both low cost, and accuracy of the order of ±0.5 mm H2O in measured head difference between the instrument’s two pressure ports. These objectives have been met, although a revision to the design of one component was found to be necessary. Deployments of up to nine months, and wireless range in excess of 300 m have been demonstrated.

  1. Optic Nerve Stimulation System with Adaptive Wireless Powering and Data Telemetry

    Directory of Open Access Journals (Sweden)

    Xing Li

    2017-12-01

    Full Text Available To treat retinal degenerative diseases, a transcorneal electrical stimulation-based system is proposed, which consists of an eye implant and an external component. The eye implant is wirelessly powered and controlled by the external component to generate the required bi-polar current pattern for transcorneal stimulation with an amplitude range of 5 μA to 320 μA, a frequency range of 10 Hz to 160 Hz and a duty ratio range of 2.5% to 20%. Power delivery control includes power boosting in preparation for stimulation, and normal power regulation that adapts to both coupling and load variations. Only one pair of coils is used for both the power link and the bi-directional data link. Except for the secondary coil, the eye implant is fully integrated on chip and is fabricated using UMC (United Microelectronics Corporation, Hsinchu, Taiwan 0.13 μm complementary metal-oxide-semiconductor (CMOS process with a size of 1.5 mm × 1.5 mm. The secondary coil is fabricated on a printed circuit board (PCB with a diameter of only 4.4 mm. After coating with biocompatible silicone, the whole implant has dimensions of 6 mm in diameter with a thickness of less than 1 mm. The whole device can be put onto the sclera and beneath the eye’s conjunctiva. System functionality and electrical performance are demonstrated with measurement results.

  2. Convergence of Photonics and Electronics for Terahertz Wireless Communications

    DEFF Research Database (Denmark)

    Salazar, Adrian Ruiz; Rommel, Simon; Anufriyev, E.

    2016-01-01

    Terahertz wireless communications are expected to offer the required high capacity and low latency performance necessary for short-range wireless access and control applications. We present an overview of some the activities in this area in the newly started H2020 ITN project CELTA: Convergence o...... of Electronics and Photonics Technologies Enabling Terahertz Applications....

  3. Wound dressing with reusable electronics for wireless monitoring

    KAUST Repository

    Shamim, Atif

    2016-10-20

    A wound dressing device with reusable electronics for wireless monitoring and a method of making the same are provided. The device can be a smart device. In an embodiment, the device has a disposable portion including one or more sensors and a reusable portion including wireless electronics. The one or more sensors can be secured to a flexible substrate and can be printed by non-contact printing on the substrate. The disposable portion can be removably coupled to the one or more sensors. The device can include one or more sensors for wireless monitoring of a wound, a wound dressing, a body fluid exuded by the wound and/or wearer health.

  4. Bio-WiTel: A Low-Power Integrated Wireless Telemetry System for Healthcare Applications in 401-406 MHz Band of MedRadio Spectrum.

    Science.gov (United States)

    Srivastava, Abhishek; Sankar K, Nithin; Chatterjee, Baibhab; Das, Devarshi; Ahmad, Meraj; Kukkundoor, Rakesh Keshava; Saraf, Vivek; Ananthapadmanabhan, Jayachandran; Sharma, Dinesh Kumar; Baghini, Maryam Shojaei

    2018-03-01

    This paper presents a low-power integrated wireless telemetry system (Bio-WiTel) for healthcare applications in 401-406 MHz frequency band of medical device radiocommunication (MedRadio) spectrum. In this paper, necessary design considerations for telemetry system for short-range (upto 3 m) communication of biosignals are presented. These considerations help greatly in making important design decisions, which eventually lead to a simple, low power, robust, and reliable wireless system implementation. Transmitter (TX) and receiver (RX) of Bio-WiTel system have been fabricated in 180 nm mixed mode CMOS technology. While radiating -18 dBm output power to a 50 antenna, the packaged TX IC consumes 250 μW power in 100% on state from 1 V supply, whereas the RX IC consumes 990 μW power from 1.8 V supply with a sensitivity of -75 dBm. Measurement results show that TX fulfils the spectral mask requirement at a maximum data rate of 72 kb/s. The measured bit error rate (BER) of RX is less than for a data rate of 200 kb/s. The proposed Bio-WiTel system is tested successfully in home and hospital environments for the communication of electrocardiogram and photoplethysmogram signals at a data rate of 57.6 kb/s with a measured BER of <10 for a maximum distance of 3 m.

  5. SISTEM TELEMETRI SIMULASI MITIGASI BENCANA KEGEMPAAN DAN DETEKSI PENINGKATAN KADAR KONDUKTIVITAS BELERANG PADA GUNUNG BERAPI BERBASIS WIRELESS 802.15.4

    Directory of Open Access Journals (Sweden)

    Yuhananisa P

    2015-01-01

    Full Text Available Penelitian laboratorium tentang sistem simulasi telemetri kebencanaan ini dilaksanakan fokus pada beberapa bagian dari parameter kebencanaan untuk mengetahui karakter dari gejala alam yang terjadi. Parameter yang diamati adalah konduktifitas kadar belerang pada perairan gunung berapi dan intensitas gempa yang terjadi. Tehnik yang dilakukan adalah dengan perancangan alat instrumentasi dengan menggunkan sensor getar meas vibration sensor dan elektroda tembaga sebagai sensor konduktivitas belerang. Data yang diperoleh dikirimkan dengan sistem telemetri menggunakan Xbee wireless dengan protokol 802.15.4. Data yang telah dikirimkan berupa data analog yang diubah dalam bentuk analogue to digital converter (ADC. Parameter yang dikontrol dalam simulasi ini adalah volume cairan sebesar 10 ml, serta suhu ruang sebesar 32 °C dan kelembapan sebesar 73%. Hasil-hasil data yang terkirim pada instrumen penerima tercatat bahwa besar konduktivitas untuk masa 0 gr sebesar 0.01361 KΩ-1. Untuk data mulai 5.011 gr hingga 20.002 gr besarnya konduktivitas adalah antara 0.01000 KΩ-1hingga 0.01418 KΩ-1. Data sensor getaran antara percobaan 0 gr hingga 20.002 gr besarnya dalam satuan tegangan bernilai 2.752 volt meningkat sampai 3.724 volt.Kata Kunci: Xbee, Konduktivitas, Sensor getar, Simulasi, Simulasi Wireless

  6. 30 pJ/b, 67 Mbps, Centimeter-to-Meter Range Data Telemetry With an IR-UWB Wireless Link.

    Science.gov (United States)

    Ebrazeh, Ali; Mohseni, Pedram

    2015-06-01

    This paper reports an energy-efficient, impulse radio ultra wideband (IR-UWB) wireless link operating in 3-5 GHz for data telemetry over centimeter-to-meter range distances at rates extended to tens of Mbps. The link comprises an all-digital, integrated transmitter (TX) fabricated in 90 nm 1P/9M CMOS that incorporates a waveform-synthesis pulse generator and a timing generator for on-off-keying (OOK) pulse modulation and phase scrambling. The link also incorporates an energy-detection receiver (RX) realized with commercial off-the-shelf (COTS) components that performs radio-frequency (RF) filtering, amplification, logarithmic power detection for data demodulation and automatic level control for robust operation in the presence of distance variations. Employing a miniaturized, UWB, chip antenna for the TX and RX, wireless transmission of pseudo-random binary sequence (PRBS) data at rates up to 50 Mbps over 10 cm-1 m is shown. Further, employing a high-gain horn antenna for the RX, wireless transmission of PRBS data at rates up to 67 Mbps over 50 cm-4 m is shown with a TX energy consumption of 30 pJ/b (i.e., power consumption of 2 mW) from 1.2 V. The measured bit error rate (BER) in both cases is UWB link are also included, exhibiting excellent match with those obtained from a conventional frequency-shift-keyed (FSK) link at ~433 MHz.

  7. 78 FR 16865 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2013-03-19

    ..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... Samsung Electronics Co., Ltd. of Seoul, Republic of Korea, and Samsung Telecommunications America, LLC of... certain electronic devices, including wireless communication devices, portable music and data processing...

  8. Telemetry Standards

    National Research Council Canada - National Science Library

    1999-01-01

    The Telemetry Group has prepared this document to foster the compatibility of telemetry transmitting, receiving, and signal processing equipment at the member ranges under the cognizance of the RCC...

  9. 78 FR 34669 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2013-06-10

    ..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... importing wireless communication devices, portable music and data processing devices, and tablet computers... filed by Samsung Electronics Co., Ltd. of Korea and Samsung Telecommunications America, LLC of...

  10. 77 FR 44671 - Certain Wireless Consumer Electronics Devices and Components Thereof; Notice of Receipt of...

    Science.gov (United States)

    2012-07-30

    ... Communications, Inc. of CA; LG Electronics, Inc. of Korea; LG Electronics U.S.A., Inc. of NJ; Nintendo Co., Ltd... INTERNATIONAL TRADE COMMISSION [Docket No. 2904] Certain Wireless Consumer Electronics Devices and.... International Trade Commission has received a complaint entitled Certain Wireless Consumer Electronics Devices...

  11. A Programmable Implantable Microstimulator SoC With Wireless Telemetry: Application in Closed-Loop Endocardial Stimulation for Cardiac Pacemaker.

    Science.gov (United States)

    Shuenn-Yuh Lee; Su, M Y; Ming-Chun Liang; You-Yin Chen; Cheng-Han Hsieh; Chung-Min Yang; Hsin-Yi Lai; Jou-Wei Lin; Qiang Fang

    2011-12-01

    A low-power, wireless, and implantable microstimulator system on chip with smart powering management, immediate neural signal acquisition, and wireless rechargeable system is proposed. A system controller with parity checking handles the adjustable stimulus parameters for the stimulated objective. In the current paper, the rat's intra-cardiac electrogram is employed as the stimulated model in the animal study, and it is sensed by a low-voltage and low-power monitoring analog front end. The power management unit, which includes a rectifier, battery charging and detection, and a regulator, is used for the power control of the internal circuits. The stimulation data and required clock are extracted by a phase-locked-loop-based phase shift keying demodulator from an inductive AC signal. The full chip, which consumes 48 μW only, is fabricated in a TSMC 0.35 μm 2P4M standard CMOS process to perform the monitoring and pacing functions with inductively powered communication in the in vivo study.

  12. Telemetry System of Biological Parameters

    Directory of Open Access Journals (Sweden)

    Jan Spisak

    2005-01-01

    Full Text Available The mobile telemetry system of biological parameters serves for reading and wireless data transfer of measured values of selected biological parameters to an outlying computer. It concerns basically long time monitoring of vital function of car pilot.The goal of this projects is to propose mobile telemetry system for reading, wireless transfer and processing of biological parameters of car pilot during physical and psychical stress. It has to be made with respect to minimal consumption, weight and maximal device mobility. This system has to eliminate signal noise, which is created by biological artifacts and disturbances during the data transfer.

  13. Wearable salivary uric acid mouthguard biosensor with integrated wireless electronics.

    Science.gov (United States)

    Kim, Jayoung; Imani, Somayeh; de Araujo, William R; Warchall, Julian; Valdés-Ramírez, Gabriela; Paixão, Thiago R L C; Mercier, Patrick P; Wang, Joseph

    2015-12-15

    This article demonstrates an instrumented mouthguard capable of non-invasively monitoring salivary uric acid (SUA) levels. The enzyme (uricase)-modified screen printed electrode system has been integrated onto a mouthguard platform along with anatomically-miniaturized instrumentation electronics featuring a potentiostat, microcontroller, and a Bluetooth Low Energy (BLE) transceiver. Unlike RFID-based biosensing systems, which require large proximal power sources, the developed platform enables real-time wireless transmission of the sensed information to standard smartphones, laptops, and other consumer electronics for on-demand processing, diagnostics, or storage. The mouthguard biosensor system offers high sensitivity, selectivity, and stability towards uric acid detection in human saliva, covering the concentration ranges for both healthy people and hyperuricemia patients. The new wireless mouthguard biosensor system is able to monitor SUA level in real-time and continuous fashion, and can be readily expanded to an array of sensors for different analytes to enable an attractive wearable monitoring system for diverse health and fitness applications. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. 77 FR 70464 - Certain Electronic Devices, Including Wireless Communication Devices, Portable Music and Data...

    Science.gov (United States)

    2012-11-26

    ..., Including Wireless Communication Devices, Portable Music and Data Processing Devices, and Tablet Computers... Samsung Electronics Co., Ltd. of Korea and Samsung Telecommunications America, LLC of Richardson, Texas... wireless communication devices, portable music and data processing devices, and tablet computers, by reason...

  15. Convergence of photonics and electronics for Terahertz wireless communications – the ITN CELTA project

    DEFF Research Database (Denmark)

    Tafur Monroy, Idelfonso

    2016-01-01

    Terahertz wireless communications is expected to offer the required high capacity and low latency performance required from short-range wireless access and control applications. We present an overview of some the activities in this area in the newly started H2020 ITN project CELTA: convergence of...... of electronics and photonics technologies enabling Terahertz applications...

  16. 78 FR 56245 - Certain Wireless Consumer Electronics Devices and Components Thereof; Notice of Request for...

    Science.gov (United States)

    2013-09-12

    ... Communications, Inc. of San Diego, California; LG Electronics, Inc. of Seoul, Korea; LG Electronics U.S.A., Inc... Electronics Devices and Components Thereof; Notice of Request for Statements on the Public Interest AGENCY: U... wireless consumer electronics devices and components thereof imported by respondents Acer, Inc. of Taipei...

  17. 78 FR 12354 - Certain Wireless Consumer Electronics Devices and Components Thereof; Commission Determination...

    Science.gov (United States)

    2013-02-22

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-853] Certain Wireless Consumer Electronics Devices and Components Thereof; Commission Determination Concerning an Initial Determination Granting a Motion To Amend Complaint and Notice of Investigation AGENCY: U.S. International Trade...

  18. 77 FR 60720 - Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data...

    Science.gov (United States)

    2012-10-04

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-794] Certain Electronic Devices, Including Wireless Commmunication Devices, Portable Music and Data Processing Devices, and Tablet Computers... communication devices, portable music and data processing devices, and tablet computers, imported by Apple Inc...

  19. On-Demand Telemetry

    Data.gov (United States)

    National Aeronautics and Space Administration — AFRC has previously investigated the use of Network Based Telemetry. We will be building on that research to enable On-Demand Telemetry. On-Demand Telemetry is a way...

  20. A wearable “electronic patch” for wireless continuous monitoring of chronically diseased patients

    DEFF Research Database (Denmark)

    Haahr, Rasmus Grønbek; Duun, Sune; Thomsen, Erik Vilain

    2008-01-01

    We present a wearable health system (WHS) for non-invasive and wireless monitoring of physiological signals. The system is made as an electronic patch where sensors, low power electronics, and radio communication are integrated in an adhesive material of hydrocolloid polymer making it a sticking...

  1. Systems For Telemetry And Telecontrol - Practical Applications

    International Nuclear Information System (INIS)

    Stankovski, Mile J.; Kolemishevska-Gugulovska, Tatjana; Stanojkovski, Ratko

    2003-01-01

    This paper present practical aspects in application of telemetry and tele control using new aspect of electronics, signal processing, telecommunications, and of course theory of control systems. In the paper some aspects during the design of telemetry and tele control systems are presented. Also it is presented one real system of telemetry and tele control in water distribution, level measurement in four tanks on the different locations. (Author)

  2. 75 FR 10502 - In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices...

    Science.gov (United States)

    2010-03-08

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-667; Investigation No. 337-TA-673] In the Matter of Certain Electronic Devices, Including Handheld Wireless Communications Devices; Notice of... Entirety AGENCY: U.S. International Trade Commission. ACTION: Notice. SUMMARY: Notice is hereby given that...

  3. Identification of high-risk areas for harbour porpoise Phocoena phocoena bycatch using remote electronic monitoring and satellite telemetry data

    DEFF Research Database (Denmark)

    Kindt-Larsen, Lotte; Berg, Casper Willestofte; Tougaard, J.

    2016-01-01

    The bycatch of harbour porpoise Phocoena phocoena is an issue of major concern for fisheries management and for porpoise conservation. We used high-resolution spatial and temporal data on porpoise abundance and fishing effort from the Danish Skagerrak Sea to identify areas with potentially higher...... telemetry or REM data allow for identification of areas of potential high and low bycatch risk, and better predictions are obtained when combining the 2 sources of data. The final model can thus be used as a tool to identify areas of bycatch risk...

  4. Electronic Devices, Methods, and Computer Program Products for Selecting an Antenna Element Based on a Wireless Communication Performance Criterion

    DEFF Research Database (Denmark)

    2014-01-01

    A method of operating an electronic device includes providing a plurality of antenna elements, evaluating a wireless communication performance criterion to obtain a performance evaluation, and assigning a first one of the plurality of antenna elements to a main wireless signal reception and trans...

  5. UAV telemetry communications using ZigBee protocol

    Science.gov (United States)

    Nasution, T. H.; Siregar, I.; Yasir, M.

    2017-10-01

    Wireless communication has been widely used in various fields or disciplines such as agriculture, health, engineering, military, and aerospace so as to support the work in that field. The communication technology is typically used for controlling devices and data monitoring. One development of wireless communication is the widely used telemetry system used to reach areas that cannot be reached by humans using UAV (Unmanned Aerial Vehicle) or unmanned aircraft. In this paper we discuss the design of telemetry system in UAV using ZigBee protocol. From the test obtained the system can work well with visualization displays without pause is 20 data per second with a maximum data length of 120 characters.

  6. Combined radar and telemetry system

    Energy Technology Data Exchange (ETDEWEB)

    Rodenbeck, Christopher T.; Young, Derek; Chou, Tina; Hsieh, Lung-Hwa; Conover, Kurt; Heintzleman, Richard

    2017-08-01

    A combined radar and telemetry system is described. The combined radar and telemetry system includes a processing unit that executes instructions, where the instructions define a radar waveform and a telemetry waveform. The processor outputs a digital baseband signal based upon the instructions, where the digital baseband signal is based upon the radar waveform and the telemetry waveform. A radar and telemetry circuit transmits, simultaneously, a radar signal and telemetry signal based upon the digital baseband signal.

  7. Advanced Telemetry System Development.

    Science.gov (United States)

    Progress in advanced telemetry system development is described. Discussions are included of studies leading to the specification for design...Progress indicates that further sophistication of existing designs in telemetry will be less advantageous than the development of new systems of

  8. Spitzer Telemetry Processing System

    Science.gov (United States)

    Stanboli, Alice; Martinez, Elmain M.; McAuley, James M.

    2013-01-01

    The Spitzer Telemetry Processing System (SirtfTlmProc) was designed to address objectives of JPL's Multi-mission Image Processing Lab (MIPL) in processing spacecraft telemetry and distributing the resulting data to the science community. To minimize costs and maximize operability, the software design focused on automated error recovery, performance, and information management. The system processes telemetry from the Spitzer spacecraft and delivers Level 0 products to the Spitzer Science Center. SirtfTlmProc is a unique system with automated error notification and recovery, with a real-time continuous service that can go quiescent after periods of inactivity. The software can process 2 GB of telemetry and deliver Level 0 science products to the end user in four hours. It provides analysis tools so the operator can manage the system and troubleshoot problems. It automates telemetry processing in order to reduce staffing costs.

  9. A Harsh Environment Wireless Pressure Sensing Solution Utilizing High Temperature Electronics

    Directory of Open Access Journals (Sweden)

    Jie Yang

    2013-02-01

    Full Text Available Pressure measurement under harsh environments, especially at high temperatures, is of great interest to many industries. The applicability of current pressure sensing technologies in extreme environments is limited by the embedded electronics which cannot survive beyond 300 °C ambient temperature as of today. In this paper, a pressure signal processing and wireless transmission module based on the cutting-edge Silicon Carbide (SiC devices is designed and developed, for a commercial piezoresistive MEMS pressure sensor from Kulite Semiconductor Products, Inc. Equipped with this advanced high-temperature SiC electronics, not only the sensor head, but the entire pressure sensor suite is capable of operating at 450 °C. The addition of wireless functionality also makes the pressure sensor more flexible in harsh environments by eliminating the costly and fragile cable connections. The proposed approach was verified through prototype fabrication and high temperature bench testing from room temperature up to 450 °C. This novel high-temperature pressure sensing technology can be applied in real-time health monitoring of many systems involving harsh environments, such as military and commercial turbine engines.

  10. A Harsh Environment Wireless Pressure Sensing Solution Utilizing High Temperature Electronics

    Science.gov (United States)

    Yang, Jie

    2013-01-01

    Pressure measurement under harsh environments, especially at high temperatures, is of great interest to many industries. The applicability of current pressure sensing technologies in extreme environments is limited by the embedded electronics which cannot survive beyond 300 °C ambient temperature as of today. In this paper, a pressure signal processing and wireless transmission module based on the cutting-edge Silicon Carbide (SiC) devices is designed and developed, for a commercial piezoresistive MEMS pressure sensor from Kulite Semiconductor Products, Inc. Equipped with this advanced high-temperature SiC electronics, not only the sensor head, but the entire pressure sensor suite is capable of operating at 450 °C. The addition of wireless functionality also makes the pressure sensor more flexible in harsh environments by eliminating the costly and fragile cable connections. The proposed approach was verified through prototype fabrication and high temperature bench testing from room temperature up to 450 °C. This novel high-temperature pressure sensing technology can be applied in real-time health monitoring of many systems involving harsh environments, such as military and commercial turbine engines. PMID:23447006

  11. Animal Telemetry Network (ATN)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — These data (updated daily) are from the Animal Telemetry Network (ATN) program. Begun as one of the field projects in the international Census of Marine Life, the...

  12. Telemetry-Based Ranging

    Science.gov (United States)

    Hamkins, Jon; Vilnrotter, Victor A.; Andrews, Kenneth S.; Shambayati, Shervin

    2011-01-01

    A telemetry-based ranging scheme was developed in which the downlink ranging signal is eliminated, and the range is computed directly from the downlink telemetry signal. This is the first Deep Space Network (DSN) ranging technology that does not require the spacecraft to transmit a separate ranging signal. By contrast, the evolutionary ranging techniques used over the years by NASA missions, including sequential ranging (transmission of a sequence of sinusoids) and PN-ranging (transmission of a pseudo-noise sequence) whether regenerative (spacecraft acquires, then regenerates and retransmits a noise-free ranging signal) or transparent (spacecraft feeds the noisy demodulated uplink ranging signal into the downlink phase modulator) relied on spacecraft power and bandwidth to transmit an explicit ranging signal. The state of the art in ranging is described in an emerging CCSDS (Consultative Committee for Space Data Systems) standard, in which a pseudo-noise (PN) sequence is transmitted from the ground to the spacecraft, acquired onboard, and the PN sequence is coherently retransmitted back to the ground, where a delay measurement is made between the uplink and downlink signals. In this work, the telemetry signal is aligned with the uplink PN code epoch. The ground station computes the delay between the uplink signal transmission and the received downlink telemetry. Such a computation is feasible because symbol synchronizability is already an integral part of the telemetry design. Under existing technology, the telemetry signal cannot be used for ranging because its arrival-time information is not coherent with any Earth reference signal. By introducing this coherence, and performing joint telemetry detection and arrival-time estimation on the ground, a high-rate telemetry signal can provide all the precision necessary for spacecraft ranging.

  13. 3-Coil resonance-based wireless power transfer system for implantable electronic

    KAUST Repository

    Yi, Ying

    2013-05-01

    This paper presents a 3-coil resonance-based wireless power transfer (R-WPT) system using a single layer of inductor coil windings, in a pancake configuration, in order to obtain a compact system for implantable electronic applications. A theoretical analysis and experimental measurements in terms of quality factor Q and power transfer efficiency (PTE), was done. Our proposed 3-coil scheme can achieve a high PTE with a resonance frequency of 2.46 MHz over a transfer distance of up to 30 mm, by using two 15-mm radius implant coils. The achieved experimental PTE is more than 85%at a 5 mm separation distance, and about 50% PTE at a distance of 20 mm. © 2013 IEEE.

  14. Power Electronics Design of a Solar Powered In-car Wireless Tag for Asset Tracking and Parking Applications

    International Nuclear Information System (INIS)

    Zhu, D; Beeby, S P; Henaut, J

    2014-01-01

    This paper reports the design and testing of a power conditioning circuit for a solar powered in-car wireless tag for asset tracking and parking application. Existing long range asset tracking is based on the GSM/GPRS network, which requires expensive subscriptions. The EU FP7 project CEWITT aims at developing a credit card sized autonomous wireless tag with GNSS geo-positioning capabilities to ensure the integrity and cost effectiveness for parking applications. It was found in previous research that solar cells are the most suitable energy sources for this application. This study focused on the power electronics design for the wireless tag. A suitable solar cell was chosen for its high power density. Charging circuit, hysteresis control circuit and LDO were designed and integrated to meet the system requirement. Test results showed that charging efficiency of 80 % had been achieved

  15. Power Electronics Design of a Solar Powered In-car Wireless Tag for Asset Tracking and Parking Applications

    Science.gov (United States)

    Zhu, D.; Henaut, J.; Beeby, S. P.

    2014-11-01

    This paper reports the design and testing of a power conditioning circuit for a solar powered in-car wireless tag for asset tracking and parking application. Existing long range asset tracking is based on the GSM/GPRS network, which requires expensive subscriptions. The EU FP7 project CEWITT aims at developing a credit card sized autonomous wireless tag with GNSS geo-positioning capabilities to ensure the integrity and cost effectiveness for parking applications. It was found in previous research that solar cells are the most suitable energy sources for this application. This study focused on the power electronics design for the wireless tag. A suitable solar cell was chosen for its high power density. Charging circuit, hysteresis control circuit and LDO were designed and integrated to meet the system requirement. Test results showed that charging efficiency of 80 % had been achieved.

  16. The Language of Glove: Wireless gesture decoder with low-power and stretchable hybrid electronics.

    Science.gov (United States)

    O'Connor, Timothy F; Fach, Matthew E; Miller, Rachel; Root, Samuel E; Mercier, Patrick P; Lipomi, Darren J

    2017-01-01

    This communication describes a glove capable of wirelessly translating the American Sign Language (ASL) alphabet into text displayable on a computer or smartphone. The key components of the device are strain sensors comprising a piezoresistive composite of carbon particles embedded in a fluoroelastomer. These sensors are integrated with a wearable electronic module consisting of digitizers, a microcontroller, and a Bluetooth radio. Finite-element analysis predicts a peak strain on the sensors of 5% when the knuckles are fully bent. Fatigue studies suggest that the sensors successfully detect the articulation of the knuckles even when bent to their maximal degree 1,000 times. In concert with an accelerometer and pressure sensors, the glove is able to translate all 26 letters of the ASL alphabet. Lastly, data taken from the glove are used to control a virtual hand; this application suggests new ways in which stretchable and wearable electronics can enable humans to interface with virtual environments. Critically, this system was constructed of components costing less than $100 and did not require chemical synthesis or access to a cleanroom. It can thus be used as a test bed for materials scientists to evaluate the performance of new materials and flexible and stretchable hybrid electronics.

  17. The Language of Glove: Wireless gesture decoder with low-power and stretchable hybrid electronics.

    Directory of Open Access Journals (Sweden)

    Timothy F O'Connor

    Full Text Available This communication describes a glove capable of wirelessly translating the American Sign Language (ASL alphabet into text displayable on a computer or smartphone. The key components of the device are strain sensors comprising a piezoresistive composite of carbon particles embedded in a fluoroelastomer. These sensors are integrated with a wearable electronic module consisting of digitizers, a microcontroller, and a Bluetooth radio. Finite-element analysis predicts a peak strain on the sensors of 5% when the knuckles are fully bent. Fatigue studies suggest that the sensors successfully detect the articulation of the knuckles even when bent to their maximal degree 1,000 times. In concert with an accelerometer and pressure sensors, the glove is able to translate all 26 letters of the ASL alphabet. Lastly, data taken from the glove are used to control a virtual hand; this application suggests new ways in which stretchable and wearable electronics can enable humans to interface with virtual environments. Critically, this system was constructed of components costing less than $100 and did not require chemical synthesis or access to a cleanroom. It can thus be used as a test bed for materials scientists to evaluate the performance of new materials and flexible and stretchable hybrid electronics.

  18. The Language of Glove: Wireless gesture decoder with low-power and stretchable hybrid electronics

    Science.gov (United States)

    O’Connor, Timothy F.; Fach, Matthew E.; Miller, Rachel; Root, Samuel E.; Mercier, Patrick P.

    2017-01-01

    This communication describes a glove capable of wirelessly translating the American Sign Language (ASL) alphabet into text displayable on a computer or smartphone. The key components of the device are strain sensors comprising a piezoresistive composite of carbon particles embedded in a fluoroelastomer. These sensors are integrated with a wearable electronic module consisting of digitizers, a microcontroller, and a Bluetooth radio. Finite-element analysis predicts a peak strain on the sensors of 5% when the knuckles are fully bent. Fatigue studies suggest that the sensors successfully detect the articulation of the knuckles even when bent to their maximal degree 1,000 times. In concert with an accelerometer and pressure sensors, the glove is able to translate all 26 letters of the ASL alphabet. Lastly, data taken from the glove are used to control a virtual hand; this application suggests new ways in which stretchable and wearable electronics can enable humans to interface with virtual environments. Critically, this system was constructed of components costing less than $100 and did not require chemical synthesis or access to a cleanroom. It can thus be used as a test bed for materials scientists to evaluate the performance of new materials and flexible and stretchable hybrid electronics. PMID:28700603

  19. A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

    Directory of Open Access Journals (Sweden)

    Parsaei H.

    2017-03-01

    Full Text Available Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is unsuitable for observing inaccessible patients in some conditions such as during CT scan. Objective: A wireless electronic esophageal stethoscope is designed for continues auscultation of heart and lung sounds in anesthetized patients. The system consists of a transmitter and a receiver. The former acquires, amplifies and transmits the acquired sound signals to the latter via a frequency modulation transmitter. The receiver demodulates, amplifies, and delivers the received signal to a headphone to be heard by anesthesiologist. Results: The usability and effectiveness of the designed system was qualitatively evaluated by 5 anesthesiologists in Namazi Hospital and Shahid Chamran Hospital, Shiraz, Iran on 30 patients in several operating rooms in different conditions; e.g., when electro surgery instruments are working. Fortunately, the experts on average ranked good quality for the heard heart and lung sounds and very good on the user friendly being of the instrument. Conclusion: Evaluation results demonstrate that the developed system is capable of capturing and transmitting heart and lung sounds successfully. Therefore, it can be used to continuously monitor anesthetized patients’ cardiac and respiratory function. Since via the instrument wireless auscultation is possible, it could be suitable for observing inaccessible patients in several conditions such as during CT scan.

  20. Rapidly Deployed Modular Telemetry System

    Science.gov (United States)

    Varnavas, Kosta A. (Inventor); Sims, William Herbert, III (Inventor)

    2013-01-01

    The present invention is a telemetry system, and more specifically is a rapidly deployed modular telemetry apparatus which utilizes of SDR technology and the FPGA programming capability to reduce the number of hardware components and programming required to deploy a telemetry system.

  1. Phoenix Telemetry Processor

    Science.gov (United States)

    Stanboli, Alice

    2013-01-01

    Phxtelemproc is a C/C++ based telemetry processing program that processes SFDU telemetry packets from the Telemetry Data System (TDS). It generates Experiment Data Records (EDRs) for several instruments including surface stereo imager (SSI); robotic arm camera (RAC); robotic arm (RA); microscopy, electrochemistry, and conductivity analyzer (MECA); and the optical microscope (OM). It processes both uncompressed and compressed telemetry, and incorporates unique subroutines for the following compression algorithms: JPEG Arithmetic, JPEG Huffman, Rice, LUT3, RA, and SX4. This program was in the critical path for the daily command cycle of the Phoenix mission. The products generated by this program were part of the RA commanding process, as well as the SSI, RAC, OM, and MECA image and science analysis process. Its output products were used to advance science of the near polar regions of Mars, and were used to prove that water is found in abundance there. Phxtelemproc is part of the MIPL (Multi-mission Image Processing Laboratory) system. This software produced Level 1 products used to analyze images returned by in situ spacecraft. It ultimately assisted in operations, planning, commanding, science, and outreach.

  2. Wireless connection of continuous glucose monitoring system to the electronic patient record

    Science.gov (United States)

    Murakami, Alexandre; Gutierrez, Marco A.; Lage, Silvia G.; Rebelo, Marina S.; Granja, Luiz A. R.; Ramires, Jose A. F.

    2005-04-01

    The control of blood sugar level (BSL) at near-normal levels has been documented to reduce both acute and chronic complications of diabetes mellitus. Recent studies suggested, the reduction of mortality in a surgical intensive care unit (ICU), when the BSL are maintained at normal levels. Despite of the benefits appointed by these and others clinical studies, the strict BSL control in critically ill patients suffers from some difficulties: a) medical staff need to measure and control the patient"s BSL using blood sample at least every hour. This is a complex and time consuming task; b) the inaccuracy of standard capillary glucose monitoring (fingerstick) in hypotensive patients and, if frequently used to sample arterial or venous blood, may lead to excess phlebotomy; c) there is no validated procedure for continuously monitoring of BSL levels. This study used the MiniMed CGMS in ill patients at ICU to send, in real-time, BSL values to a Web-Based Electronic Patient Record. The BSL values are parsed and delivered through a wireless network as an HL7 message. The HL7 messages with BSL values are collected, stored into the Electronic Patient Record and presented into a bed-side monitor at the ICU together with other relevant patient information.

  3. Integrated Plan-Procedures-Telemetry Ops Concept and Prototype

    Data.gov (United States)

    National Aeronautics and Space Administration — The project scope includes developing the ops concept and prototype for a near-seamless interface between mission plans, electronic procedures and live telemetry...

  4. Using Wireless Power Meters to Measure Energy Use of Miscellaneous and Electronic Devices in Buildings

    Energy Technology Data Exchange (ETDEWEB)

    UC Berkeley, Berkeley, CA USA; Brown, Richard; Lanzisera, Steven; Cheung, Hoi Ying (Iris); Lai, Judy; Jiang, Xiaofan; Dawson-Haggerty, Stephen; Taneja, Jay; Ortiz, Jorge; Culler, David

    2011-05-24

    Miscellaneous and electronic devices consume about one-third of the primary energy used in U.S. buildings, and their energy use is increasing faster than other end-uses. Despite the success of policies, such as Energy Star, that promote more efficient miscellaneous and electronic products, much remains to be done to address the energy use of these devices if we are to achieve our energy and carbon reduction goals. Developing efficiency strategies for these products depends on better data about their actual usage, but very few studies have collected field data on the long-term energy used by a large sample of devices due to the difficulty and expense of collecting device-level energy data. This paper describes the development of an improved method for collecting device-level energy and power data using small, relatively inexpensive wireless power meters. These meters form a mesh network based on Internet standard protocols and can form networks of hundreds of metering points in a single building. Because the meters are relatively inexpensive and do not require manual data downloading, they can be left in the field for months or years to collect long time-series energy use data. In addition to the metering technology, we also describe a field protocol used to collect comprehensive, robust data on the miscellaneous and electronic devices in a building. The paper presents sample results from several case study buildings, in which all the plug-in devices for several homes were metered, and a representative sample of several hundred plug-in devices in a commercial office building were metered for several months.

  5. The application of GPS time information in the telemetry ground station

    International Nuclear Information System (INIS)

    Zhang Songtao; Zhang Yusong; Sun Xiurui

    2001-01-01

    GPS time information is a kind of practicable information resource that can be shared all over the world. Now it is the most accurate wireless time information. The major of this paper is the application information of GPS time information in telemetry. The main point introduces how to make use of the GPS time information to produce GPS-IRIG-B time code for proving ground and how to send time information to related equipment in telemetry ground station

  6. Telemetry System Data Latency

    Science.gov (United States)

    2017-07-13

    Two of the scenarios utilized the Windows Operating System on the GSSrs to broadcast the Chapter 10 data with different settings for buffer sizes...412TW-PA-17485 Telemetry System Data Latency. Jon Morgan AIR FORCE TEST CENTER EDWARDS AFB, CA 13 July 2017 4...Headquarters Services, Directorate for Information Operations and Reports (0704-0188), 1215 Jefferson Davis Highway, Suite 1204, Arlington, VA 22202

  7. Northern Pintail Telemetry [ds231

    Data.gov (United States)

    California Department of Resources — Using radio-telemetry, female northern pintail (Anas acuta) survival, distribution, and movements during late August-March in Central California were determined...

  8. UAN subsurface telemetry unit. Laboratory tests

    OpenAIRE

    Zabel, F.; Martins, C.

    2009-01-01

    SiPLAB Report 07/09, FCT, University of Algarve,2009. This document describes the laboratory tests performed on the Subsurface Telemetry Unit (STU) which was developped for the Underwater Acoustic Network EU-FP7 Project. The tests are separated into mechanical, energy, cable, electronics, acoustic acquisition, STU computer and the base station. This work was supported by project UAN (Underwater Acoustic Network) from the European Community's Seventh Framework Programme (FP7/2007-2013) u...

  9. Towards high-resolution retinal prostheses with direct optical addressing and inductive telemetry

    Science.gov (United States)

    Ha, Sohmyung; Khraiche, Massoud L.; Akinin, Abraham; Jing, Yi; Damle, Samir; Kuang, Yanjin; Bauchner, Sue; Lo, Yu-Hwa; Freeman, William R.; Silva, Gabriel A.; Cauwenberghs, Gert

    2016-10-01

    Objective. Despite considerable advances in retinal prostheses over the last two decades, the resolution of restored vision has remained severely limited, well below the 20/200 acuity threshold of blindness. Towards drastic improvements in spatial resolution, we present a scalable architecture for retinal prostheses in which each stimulation electrode is directly activated by incident light and powered by a common voltage pulse transferred over a single wireless inductive link. Approach. The hybrid optical addressability and electronic powering scheme provides separate spatial and temporal control over stimulation, and further provides optoelectronic gain for substantially lower light intensity thresholds than other optically addressed retinal prostheses using passive microphotodiode arrays. The architecture permits the use of high-density electrode arrays with ultra-high photosensitive silicon nanowires, obviating the need for excessive wiring and high-throughput data telemetry. Instead, the single inductive link drives the entire array of electrodes through two wires and provides external control over waveform parameters for common voltage stimulation. Main results. A complete system comprising inductive telemetry link, stimulation pulse demodulator, charge-balancing series capacitor, and nanowire-based electrode device is integrated and validated ex vivo on rat retina tissue. Significance. Measurements demonstrate control over retinal neural activity both by light and electrical bias, validating the feasibility of the proposed architecture and its system components as an important first step towards a high-resolution optically addressed retinal prosthesis.

  10. Thermoelectric Powered High Temperature Wireless Sensing

    Science.gov (United States)

    Kucukkomurler, Ahmet

    This study describes use of a thermoelectric power converter to transform waste heat into electrical energy to power an RF receiver and transmitter, for use in harsh environment wireless temperature sensing and telemetry. The sensing and transmitting module employs a DS-1820 low power digital temperature sensor to perform temperature to voltage conversion, an ATX-34 RF transmitter, an ARX-34 RF receiver module, and a PIC16f84A microcontroller to synchronize data communication between them. The unit has been tested in a laboratory environment, and promising results have been obtained for an actual automotive wireless under hood temperature sensing and telemetry implementation.

  11. 106-17 Telemetry Standards Chapter 1

    Science.gov (United States)

    2017-07-01

    Telemetry Standards, RCC Standard 106-17 Chapter 1, July 2017 1-1 CHAPTER 1 Introduction The Telemetry Standards address the here-to-date...conventional methods, techniques, and practices affiliated with aeronautical telemetry applicable to the member RCC ranges. The first 11 chapters are...generally devoted to a different element of the telemetry system or process. Chapters 21 through 28 address the topic of network telemetry . These

  12. Adaptable Transponder for Multiple Telemetry Systems

    Science.gov (United States)

    Sims, William Herbert, III (Inventor); Varnavas, Kosta A. (Inventor)

    2014-01-01

    The present invention is a stackable telemetry circuit board for use in telemetry systems for satellites and other purposes. The present invention incorporates previously-qualified interchangeable circuit boards, or "decks," that perform functions such as power, signal receiving and transmission, and processing. Each deck is adapted to serve a range of telemetry applications. This provides flexibility in the construction of the stackable telemetry circuit board and significantly reduces the cost and time necessary to develop a telemetry system.

  13. Telemetry-Enhancing Scripts

    Science.gov (United States)

    Maimone, Mark W.

    2009-01-01

    Scripts Providing a Cool Kit of Telemetry Enhancing Tools (SPACKLE) is a set of software tools that fill gaps in capabilities of other software used in processing downlinked data in the Mars Exploration Rovers (MER) flight and test-bed operations. SPACKLE tools have helped to accelerate the automatic processing and interpretation of MER mission data, enabling non-experts to understand and/or use MER query and data product command simulation software tools more effectively. SPACKLE has greatly accelerated some operations and provides new capabilities. The tools of SPACKLE are written, variously, in Perl or the C or C++ language. They perform a variety of search and shortcut functions that include the following: Generating text-only, Event Report-annotated, and Web-enhanced views of command sequences; Labeling integer enumerations with their symbolic meanings in text messages and engineering channels; Systematic detecting of corruption within data products; Generating text-only displays of data-product catalogs including downlink status; Validating and labeling of commands related to data products; Performing of convenient searches of detailed engineering data spanning multiple Martian solar days; Generating tables of initial conditions pertaining to engineering, health, and accountability data; Simplified construction and simulation of command sequences; and Fast time format conversions and sorting.

  14. An Electronic-Nose Sensor Node Based on a Polymer-Coated Surface Acoustic Wave Array for Wireless Sensor Network Applications

    Directory of Open Access Journals (Sweden)

    Kea-Tiong Tang

    2011-04-01

    Full Text Available This study developed an electronic-nose sensor node based on a polymer-coated surface acoustic wave (SAW sensor array. The sensor node comprised an SAW sensor array, a frequency readout circuit, and an Octopus II wireless module. The sensor array was fabricated on a large K2 128° YX LiNbO3 sensing substrate. On the surface of this substrate, an interdigital transducer (IDT was produced with a Cr/Au film as its metallic structure. A mixed-mode frequency readout application specific integrated circuit (ASIC was fabricated using a TSMC 0.18 μm process. The ASIC output was connected to a wireless module to transmit sensor data to a base station for data storage and analysis. This sensor node is applicable for wireless sensor network (WSN applications.

  15. An Innovative Wireless Endoscopic Capsule With Spherical Shape.

    Science.gov (United States)

    Fontana, Rossella; Mulana, Francesca; Cavallotti, Carmen; Tortora, Giuseppe; Vigliar, Mario; Vatteroni, Monica; Menciassi, Arianna

    2017-02-01

    This paper aims to contribute to the advancement of the Wireless Capsule Endoscopy (WCE) field for ColoRectal Cancer (CRC) screening, by developing all electronic circuits to build an innovative wireless endoscopic capsule with a spherical shape, conceived to reduce the friction during its locomotion and thus improving patient's acceptability. The proposed capsule embeds an image sensor with optics and Light Emitting Diodes (LEDs), a control unit with a telemetry module, an actuation system, a battery with a smart recharging circuit able to recharge in 20 minutes, a smart power-on circuit and a localization module. Everything is devised to fit in a small spherical shape with a diameter of 26 mm and a weight of 12.70 g. The authors present a description of the sub-modules involved in the capsule development, together with the firmware and hardware integration. In order to reduce the bandwidth for matching the specifications of the target commercial telemetry, the firmware interfacing of a custom encoder was performed, which is able to compress the incoming images with a negligible loss of information and occupying a number of Look Up-Tables (LUTs) less than 1780. As a preliminary work, a versatile Field Programmable Gate Arrays (FPGA) based demo-board system has been developed in order to test and optimize the functionalities and the performance of the single sub-modules and wireless vision chain system. This work allows to demonstrate the feasibility of a complex biomedical system, with severe constraints by highlighting the necessity to enhance the frame rate in the future.

  16. Implanted Antennas in Medical Wireless Communications

    CERN Document Server

    Rahmat-Samii, Yahya; Balanis, Constantine

    2006-01-01

    Implanted Antennas in Medical Wireless Communications summarizes the results of recent research activities on the subject of implanted antennas for medical wireless communication systems. It is anticipated that in the near future sophisticated medical devices will be implanted inside the human body for medical telemetry and telemedicine. To establish effective and efficient wireless links with these devices, it is pivotal to give special attention to antenna designs that are low profile, small, safe, and cost effective. In this book, authors Yahya Rahmat-Samii and Jaehoon Kim demonstrate how a

  17. An explosive acoustic telemetry system for seabed penetrators

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, G.C.; Hickerson, J.

    1988-04-01

    This report discusses the design and past applications of an explosive acoustic telemetry system (EATS) for gathering and transmitting data from seabed penetrators. The system was first fielded in 1982 and has since been used to measure penetrator performance on three other occasions. Descriptions are given of the mechanical hardware, system electronics, and software.

  18. Wireless electronic-tattoo for long-term high fidelity facial muscle recordings

    Science.gov (United States)

    Inzelberg, Lilah; David Pur, Moshe; Steinberg, Stanislav; Rand, David; Farah, Maroun; Hanein, Yael

    2017-05-01

    Facial surface electromyography (sEMG) is a powerful tool for objective evaluation of human facial expressions and was accordingly suggested in recent years for a wide range of psychological and neurological assessment applications. Owing to technical challenges, in particular the cumbersome gelled electrodes, the use of facial sEMG was so far limited. Using innovative facial temporary tattoos optimized specifically for facial applications, we demonstrate the use of sEMG as a platform for robust identification of facial muscle activation. In particular, differentiation between diverse facial muscles is demonstrated. We also demonstrate a wireless version of the system. The potential use of the presented technology for user-experience monitoring and objective psychological and neurological evaluations is discussed.

  19. Full L-S Band Telemetry System

    National Research Council Canada - National Science Library

    Jensen, Michael

    2001-01-01

    Recent changes in spectrum availability as well as higher demands for spectrum have motivated the development of telemetry transmit systems capable of fully operating over both L and S telemetry bands...

  20. Full L-S Band Telemetry System

    National Research Council Canada - National Science Library

    Jensen, Michael

    2003-01-01

    Recent changes in spectrum availability as well as higher demands for spectrum have motivated the development of telemetry transmit systems capable of fully operating over both L and S telemetry bands...

  1. Full L-S Band Telemetry System

    National Research Council Canada - National Science Library

    Jensen, Michael

    2002-01-01

    Recent changes in spectrum availability as well as higher demands for spectrum have motivated the development of telemetry transmit systems capable of fully operating over both L and S telemetry bands...

  2. XTCE. XML Telemetry and Command Exchange Tutorial

    Science.gov (United States)

    Rice, Kevin; Kizzort, Brad; Simon, Jerry

    2010-01-01

    An XML Telemetry Command Exchange (XTCE) tutoral oriented towards packets or minor frames is shown. The contents include: 1) The Basics; 2) Describing Telemetry; 3) Describing the Telemetry Format; 4) Commanding; 5) Forgotten Elements; 6) Implementing XTCE; and 7) GovSat.

  3. 47 CFR 90.238 - Telemetry operations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Telemetry operations. 90.238 Section 90.238... MOBILE RADIO SERVICES Non-Voice and Other Specialized Operations § 90.238 Telemetry operations. The use of telemetry is authorized under this part on the following frequencies. (a) 72-76 MHz (in accordance...

  4. 47 CFR 97.217 - Telemetry.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Telemetry. 97.217 Section 97.217 Telecommunication FEDERAL COMMUNICATIONS COMMISSION (CONTINUED) SAFETY AND SPECIAL RADIO SERVICES AMATEUR RADIO SERVICE Special Operations § 97.217 Telemetry. Telemetry transmitted by an amateur station on or within 50...

  5. Telemetry test methods. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Bowers, J.L.; Bullard, D.L.; Schelp, T.R.

    1978-04-01

    A flexible test system is studied and proposed to provide an extensive evaluation and testing capability for telemetry products. A distributed computer controlled, modular unit test system using Computer Automated Measurement and Control (CAMAC) standard hardware and compatible software is selected because of its flexibility of application and long term cost effectiveness.

  6. Acoustic telemetry and fisheries management

    Science.gov (United States)

    Crossin, Glenn T.; Heupel, Michelle R.; Holbrook, Christopher; Hussey, Nigel E.; Lowerre-Barbieri, Susan K; Nguyen, Vivian M.; Raby, Graham D.; Cooke, Steven J.

    2017-01-01

    This paper reviews the use of acoustic telemetry as a tool for addressing issues in fisheries management, and serves as the lead to the special Feature Issue of Ecological Applications titled “Acoustic Telemetry and Fisheries Management”. Specifically, we provide an overview of the ways in which acoustic telemetry can be used to inform issues central to the ecology, conservation, and management of exploited and/or imperiled fish species. Despite great strides in this area in recent years, there are comparatively few examples where data have been applied directly to influence fisheries management and policy. We review the literature on this issue, identify the strengths and weaknesses of work done to date, and highlight knowledge gaps and difficulties in applying empirical fish telemetry studies to fisheries policy and practice. We then highlight the key areas of management and policy addressed, as well as the challenges that needed to be overcome to do this. We conclude with a set of recommendations about how researchers can, in consultation with stock assessment scientists and managers, formulate testable scientific questions to address and design future studies to generate data that can be used in a meaningful way by fisheries management and conservation practitioners. We also urge the involvement of relevant stakeholders (managers, fishers, conservation societies, etc.) early on in the process (i.e. in the co-creation of research projects), so that all priority questions and issues can be addressed effectively.

  7. A Wireless and Portable Electronic Nose to Differentiate Musts of Different Ripeness Degree and Grape Varieties

    Directory of Open Access Journals (Sweden)

    Manuel Aleixandre

    2015-04-01

    Full Text Available Two novel applications using a portable and wireless sensor system (e-nose for the wine producing industry—The recognition and classification of musts coming from different grape ripening times and from different grape varieties—Are reported in this paper. These applications are very interesting because a lot of varieties of grapes produce musts with low and similar aromatic intensities so they are very difficult to distinguish using a sensory panel. Therefore the system could be used to monitor the ripening evolution of the different types of grapes and to assess some useful characteristics, such as the identification of the grape variety origin and to prediction of the wine quality. Ripening grade of collected samples have been also evaluated by classical analytical techniques, measuring physicochemical parameters, such as, pH, Brix, Total Acidity (TA and Probable Grade Alcoholic (PGA. The measurements were carried out for two different harvests, using different red (Barbera, Petit Verdot, Tempranillo, and Touriga and white (Malvar, Malvasía, Chenin Blanc, and Sauvignon Blanc grape musts coming from the experimental cellar of the IMIDRA at Madrid. Principal Component Analysis (PCA and Probabilistic Neural Networks (PNN have been used to analyse the obtained data by e-nose. In addition, and the Canonical Correlation Analysis (CCA method has been carried out to correlate the results obtained by both technologies.

  8. 78 FR 1247 - Certain Electronic Devices, Including Wireless Communication Devices, Tablet Computers, Media...

    Science.gov (United States)

    2013-01-08

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-862] Certain Electronic Devices, Including...; Institution of Investigation Pursuant to United States Code AGENCY: U.S. International Trade Commission... Trade Commission on November 30, 2012, under section 337 of the Tariff Act of 1930, as amended, 19 U.S.C...

  9. An inkjet printed near isotropic 3-D antenna with embedded electronics for wireless sensor applications

    KAUST Repository

    Farooqui, Muhammad Fahad

    2014-07-01

    A 3-D (cube-shaped) antenna, which has been inkjet printed on a paper substrate and integrated with embedded electronics, is presented for the first time. A 1.5λ0 dipole is uniquely implemented on all the faces of the cube to achieve near isotropic radiation pattern. The antenna measures 13mm × 13mm × 13mm, where each side of the cube corresponds to only 0.1λ0 (at 2.4 GHz). Measurements with driving electronics placed inside the cube have shown that the antenna performance is not affected by the presence of embedded circuits. The cube antenna design is highly suitable for mobile sensing applications.

  10. Radio telemetry devices to monitor breathing in non-sedated animals.

    Science.gov (United States)

    Samson, Nathalie; Dumont, Sylvain; Specq, Marie-Laure; Praud, Jean-Paul

    2011-12-15

    Radio telemetry equipment has significantly improved over the last 10-15 years and is increasingly being used in research for monitoring a variety of physiological parameters in non-sedated animals. The aim of this review is to provide an update on the current state of development of radio telemetry for recording respiration. Our literature review found only rare reports of respiratory studies via radio telemetry. Much of this article will hence report our experience with our custom-built radio telemetry devices designed for recording respiratory signals, together with numerous other physiological signals in lambs. Our current radio telemetry system allows to record 24 simultaneous signals 24h/day for several days. To our knowledge, this is the highest number of physiological signals, which can be recorded wirelessly. Our devices have been invaluable for studying respiration in our ovine models of preterm birth, reflux laryngitis, postnatal exposure to cigarette smoke, respiratory syncytial virus infection and nasal ventilation, all of which are relevant to neonatal respiratory problems. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. 106-17 Telemetry Standards Chapter 7 Packet Telemetry Downlink

    Science.gov (United States)

    2017-07-31

    the InitGolayEncode() function, and the encoding can be done by the Encode(v) macro of the following C code. #define GOLAY_SIZE 0x1000...function of the following C code. The 12-bit decoded and corrected word can be calculated by the Decode(v) macro from a 24-bit code word. The number of...error bits in a 24-bit code word can be gotten by the Error(v) macro from a 24-bit code word. Telemetry Standards, RCC Standard 106-17 Chapter 7

  12. Expandable Polymer Enabled Wirelessly Destructible High-Performance Solid State Electronics

    KAUST Repository

    Gumus, Abdurrahman

    2017-03-29

    In today\\'s digital age, the increasing dependence on information also makes us vulnerable to potential invasion of privacy and cyber security. Consider a scenario in which a hard drive is stolen, lost, or misplaced, which contains secured and valuable information. In such a case, it is important to have the ability to remotely destroy the sensitive part of the device (e.g., memory or processor) if it is not possible to regain it. Many emerging materials and even some traditional materials like silicon, aluminum, zinc oxide, tungsten, and magnesium, which are often used for logic processor and memory, show promise to be gradually dissolved upon exposure of various liquid medium. However, often these wet processes are too slow, fully destructive, and require assistance from the liquid materials and their suitable availability at the time of need. This study shows Joule heating effect induced thermal expansion and stress gradient between thermally expandable advanced polymeric material and flexible bulk monocrystalline silicon (100) to destroy high-performance solid state electronics as needed and under 10 s. This study also shows different stimuli-assisted smartphone-operated remote destructions of such complementary metal oxide semiconductor electronics.

  13. Wireless Access

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Wireless Access. Wireless connect to the Base station. Easy and Convenient access. Costlier as compared to the wired technology. Reliability challenges. We see it as a complementary technology to the DSL.

  14. Telemetry of Aerial Radiological Measurements

    International Nuclear Information System (INIS)

    Clark, H. W. Jr.

    2002-01-01

    Telemetry has been added to National Nuclear Security Administration's (NNSA's) Aerial Measuring System (AMS) Incident Response aircraft to accelerate availability of aerial radiological mapping data. Rapid aerial radiological mapping is promptly performed by AMS Incident Response aircraft in the event of a major radiological dispersal. The AMS airplane flies the entire potentially affected area, plus a generous margin, to provide a quick look at the extent and severity of the event. The primary result of the AMS Incident Response over flight is a map of estimated exposure rate on the ground along the flight path. Formerly, it was necessary to wait for the airplane to land before the map could be seen. Now, while the flight is still in progress, data are relayed via satellite directly from the aircraft to an operations center, where they are displayed and disseminated. This permits more timely utilization of results by decision makers and redirection of the mission to optimize its value. The current telemetry capability can cover all of North America. Extension to a global capability is under consideration

  15. System for Configuring Modular Telemetry Transponders

    Science.gov (United States)

    Varnavas, Kosta A. (Inventor); Sims, William Herbert, III (Inventor)

    2014-01-01

    A system for configuring telemetry transponder cards uses a database of error checking protocol data structures, each containing data to implement at least one CCSDS protocol algorithm. Using a user interface, a user selects at least one telemetry specific error checking protocol from the database. A compiler configures an FPGA with the data from the data structures to implement the error checking protocol.

  16. Impedance-matched drilling telemetry system

    Science.gov (United States)

    Normann, Randy A [Edgewood, NM; Mansure, Arthur J [Albuquerque, NM

    2008-04-22

    A downhole telemetry system that uses inductance or capacitance as a mode through which signal is communicated across joints between assembled lengths of pipe wherein efficiency of signal propagation through a drill string, for example, over multiple successive pipe segments is enhanced through matching impedances associated with the various telemetry system components.

  17. Enkele toepassingen van telemetrie in de cardiologie.

    NARCIS (Netherlands)

    Rookmaker, Willem Andries

    1969-01-01

    This thesis an account of an investigation into the value of telemetry (radio electrocardiography) in a number of clinical applications. Chapter 1 describes the apparatus used in telemetry and various possibilities of application. These are: A. A sender 011 the patient and a receiver elsewhere. with

  18. Biomedical Wireless Ambulatory Crew Monitor

    Science.gov (United States)

    Chmiel, Alan; Humphreys, Brad

    2009-01-01

    A compact, ambulatory biometric data acquisition system has been developed for space and commercial terrestrial use. BioWATCH (Bio medical Wireless and Ambulatory Telemetry for Crew Health) acquires signals from biomedical sensors using acquisition modules attached to a common data and power bus. Several slots allow the user to configure the unit by inserting sensor-specific modules. The data are then sent real-time from the unit over any commercially implemented wireless network including 802.11b/g, WCDMA, 3G. This system has a distributed computing hierarchy and has a common data controller on each sensor module. This allows for the modularity of the device along with the tailored ability to control the cards using a relatively small master processor. The distributed nature of this system affords the modularity, size, and power consumption that betters the current state of the art in medical ambulatory data acquisition. A new company was created to market this technology.

  19. An Overview of Acoustic Telemetry

    Energy Technology Data Exchange (ETDEWEB)

    Drumheller, D.S.

    1992-03-24

    Acoustic telemetry has been a dream of the drilling industry for the past 50 years. It offers the promise of data rates which are one-hundred times greater than existing technology. Such a system would open the door to true logging-while-drilling technology and bring enormous profits to its developers. The oil and gas industry has led in most of the attempts to develop this type of telemetry system; however, very substantial efforts have also been made through government sponsored work in the geothermal industry. None of these previous attempts have lead to a commercial telemetry system. Conceptually, the problem looks easy. The basic idea is to produce an encoded sound wave at the bottom of the well, let it propagate up the steel drillpipe, and extract the data from the signal at the surface. Unfortunately, substantial difficulties arise. The first difficult problem is to produce the sound wave. Since the most promising transmission wavelengths are about 20 feet, normal transducer efficiencies are quite low. Compounding this problem is the structural complexity of the bottomhole assembly and drillstring. For example, the acoustic impedance of the drillstring changes every 30 feet and produces an unusual scattering pattern in the acoustic transmission. This scattering pattern causes distortion of the signal and is often confused with signal attenuation. These problems are not intractable. Recent work has demonstrated that broad frequency bands exist which are capable of transmitting data at rates up to 100 bits per second. Our work has also identified the mechanism which is responsible for the observed anomalies in the patterns of signal attenuation. Furthermore in the past few years a body of experience has been developed in designing more efficient transducers for application to metal Waveguides. The direction of future work is clear. New transducer designs which are more efficient and compatible with existing downhole power supplies need to be built and tested

  20. Downhole tool adapted for telemetry

    Science.gov (United States)

    Hall, David R.; Fox, Joe

    2010-12-14

    A cycleable downhole tool such as a Jar, a hydraulic hammer, and a shock absorber adapted for telemetry. This invention applies to other tools where the active components of the tool are displaced when the tool is rotationally or translationally cycled. The invention consists of inductive or contact transmission rings that are connected by an extensible conductor. The extensible conductor permits the transmission of the signal before, after, and during the cycling of the tool. The signal may be continuous or intermittent during cycling. The invention also applies to downhole tools that do not cycle, but in operation are under such stress that an extensible conductor is beneficial. The extensible conductor may also consist of an extensible portion and a fixed portion. The extensible conductor also features clamps that maintain the conductor under stresses greater than that seen by the tool, and seals that are capable of protecting against downhole pressure and contamination.

  1. The Biolink Implantable Telemetry System

    Science.gov (United States)

    Betancourt-Zamora, Rafael J.

    1999-01-01

    Most biotelemetry applications deal with the moderated data rates of biological signals. Few people have studied the problem of transcutaneous data transmission at the rates required by NASA's Life Sciences-Advanced BioTelemetry System (LS-ABTS). Implanted telemetry eliminate the problems associated with wire breaking the skin, and permits experiments with awake and unrestrained subjects. Our goal is to build a low-power 174-216MHz Radio Frequency (RF) transmitter suitable for short range biosensor and implantable use. The BioLink Implantable Telemetry System (BITS) is composed of three major units: an Analog Data Module (ADM), a Telemetry Transmitter Module (TTM), and a Command Receiver Module (CRM). BioLink incorporates novel low-power techniques to implement a monolithic digital RF transmitter operating at 100kbps, using quadrature phase shift keying (QPSK) modulation in the 174-216MHz ISM band. As the ADM will be specific for each application, we focused on solving the problems associated with a monolithic implementation of the TTM and CRM, and this is the emphasis of this report. A system architecture based on a Frequency-Locked Loop (FLL) Frequency Synthesizer is presented, and a novel differential frequency that eliminates the need for a frequency divider is also shown. A self sizing phase modulation scheme suitable for low power implementation was also developed. A full system-level simulation of the FLL was performed and loop filter parameters were determined. The implantable antenna has been designed, simulated and constructed. An implant package compatible with the ABTS requirements is also being proposed. Extensive work performed at 200MHz in 0.5um complementary metal oxide semiconductors (CMOS) showed the feasibility of integrating the RF transmitter circuits in a single chip. The Hajimiri phase noise model was used to optimize the Voltage Controlled Oscillator (VCO) for minimum power consumption. Two test chips were fabricated in a 0.5pm, 3V CMOS

  2. Telemetry: Summary of concept and rationale

    Science.gov (United States)

    1987-12-01

    This report presents the concept and supporting rationale for the telemetry system developed by the Consultative Committee for Space Data Systems (CCSDS). The concepts, protocols and data formats developed for the telemetry system are designed for flight and ground data systems supporting conventional, contemporary free-flyer spacecraft. Data formats are designed with efficiency as a primary consideration, i.e., format overhead is minimized. The results reflect the consensus of experts from many space agencies. An overview of the CCSDS telemetry system introduces the notion of architectural layering to achieve transparent and reliable delivery of scientific and engineering sensor data (generated aboard space vehicles) to users located in space or on earth. The system is broken down into two major conceptual categories: a packet telemetry concept and a telemetry channel coding concept. Packet telemetry facilitates data transmission from source to user in a standardized and highly automated manner. It provides a mechanism for implementing common data structures and protocols which can enhance the development and operation of space mission systems. Telemetry channel coding is a method by which data can be sent from a source to a destination by processing it in such a way that distinct messages are created which are easily distinguishable from one another. This allows construction of the data with low error probability, thus improving performance of the channel.

  3. Wireless virtualization

    CERN Document Server

    Wen, Heming; Le-Ngoc, Tho

    2013-01-01

    This SpringerBriefs is an overview of the emerging field of wireless access and mobile network virtualization. It provides a clear and relevant picture of the current virtualization trends in wireless technologies by summarizing and comparing different architectures, techniques and technologies applicable to a future virtualized wireless network infrastructure. The readers are exposed to a short walkthrough of the future Internet initiative and network virtualization technologies in order to understand the potential role of wireless virtualization in the broader context of next-generation ubiq

  4. How wireless LANs can enhance the clinical environment.

    Science.gov (United States)

    Riha, Chris

    WLANs deployments in health care institutions offer clinicians opportunities to increase productivity and improve patient care with additional point-of-care access to information systems. However, they are not a panacea. Any data that needs guaranteed reliability and protection for outside interference, such as real-time cardiac monitoring, should be on networks operating in the Wireless Medical Telemetry Service (WMTS) range. The WMTS range, (608-614 MHz, 1395-1400 MHz, and 1429-1432 MHz), was established in 1999 by the FCC as a protected frequency range (in the U.S.) making these products less likely to have interference problems than devices operating in the 802.11 range. Security challenges must also be addressed as each access point is synonymous with installing a RJ45 network jack in the parking lot of a facility and inviting the general public to connect to a network. Also, increased mobility of electronic devices means battery power; thus consideration will need to be given to charging, maintaining, and disposal of batteries. WLANs offer many advantages over conventional wired LANs but they also offer many challenges in addressing security and reliability issues. WLANs are not designed to replace conventional hard-wired network infrastructure; they are designed to augment the connectivity of LANs. Even with the 802.11 g standard, which supports connectivity up to 54 Mbps, large medical image files would not have enough bandwidth on this type of wireless network. Wireless networks can enhance the health care technology infrastructure but proper selection of technology and focus on the security and reliability during the planning and installation is a definite requirement.

  5. Evolution of the LBT Telemetry System

    Science.gov (United States)

    Summers, K.; Biddick, C.; De La Peña, M. D.; Summers, D.

    2014-05-01

    The Large Binocular Telescope (LBT) Telescope Control System (TCS) records about 10GB of telemetry data per night. Additionally, the vibration monitoring system records about 9GB of telemetry data per night. Through 2013, we have amassed over 6TB of Hierarchical Data Format (HDF5) files and almost 9TB in a MySQL database of TCS and vibration data. The LBT telemetry system, in its third major revision since 2004, provides the mechanism to capture and store this data. The telemetry system has evolved from a simple HDF file system with MySQL stream definitions within the TCS, to a separate system using a MySQL database system for the definitions and data, and finally to no database use at all, using HDF5 files.

  6. HMSRP Hawaiian Monk Seal Telemetry Tag Deployments

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This project investigates foraging behavior of Hawaiian monk seals by conducting telemetry studies. During these studies, live seals are instrumented with dive...

  7. A telemetry experiment on spotted grunter Pomadasys ...

    African Journals Online (AJOL)

    associated fish in South Africa was investigated by conducting a tracking experiment on spotted grunter Pomadasys commersonnii in the East Kleinemonde Estuary. The telemetry equipment comprised two VEMCO V8 transmitters and a ...

  8. A Comprehensive Investigation of Advanced Range Telemetry

    National Research Council Canada - National Science Library

    Rice, Michael

    1999-01-01

    Data from ARTM channel sounding flights has been analyzed. A three-path model consisting of a line-of-sight path and two reflected paths adequately captures all the essential multipath features of the aeronautical telemetry channel...

  9. Wireless Internet

    NARCIS (Netherlands)

    el Zarki, M.; Heijenk, Geert; Lee, Kenneth S.; Bidgoli, H.

    This chapter addresses the topic of wireless Internet, the extension of the wireline Internet architecture to the wireless domain. As such the chapter introduces the reader to the dominant characteristics of the Internet, from its structure to the protocols that control the forwarding of data and

  10. Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs Caused by the Qi A13 Design Wireless Charging Board

    Directory of Open Access Journals (Sweden)

    Tobias Seckler

    2015-05-01

    Full Text Available Electromagnetic interference is a concern for people wearing cardiovascular implantable electronic devices (CIEDs. The aim of this study was to assess the electromagnetic compatibility between CIEDs and the magnetic field of a common wireless charging technology. To do so the voltage induced in CIEDs by Qi A13 design magnetic fields were measured and compared with the performance limits set by ISO 14117. In order to carry this out a measuring circuit was developed which can be connected with unipolar or bipolar pacemaker leads. The measuring system was positioned at the four most common implantation sites in a torso phantom filled with physiological saline solution. The phantom was exposed by using Helmholtz coils from 5 µT to 27 µT with 111 kHz sine‑bursts or by using a Qi A13 design wireless charging board (Qi‑A13‑Board in two operating modes “power transfer” and “pinging”. With the Helmholtz coils the lowest magnetic flux density at which the performance limit was exceeded is 11 µT. With the Qi‑A13‑Board in power transfer mode 10.8% and in pinging mode 45.7% (2.2% at 10 cm distance of the performance limit were reached at maximum. In neither of the scrutinized cases, did the voltage induced by the Qi‑A13‑Board exceed the performance limits.

  11. Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board.

    Science.gov (United States)

    Seckler, Tobias; Jagielski, Kai; Stunder, Dominik

    2015-05-27

    Electromagnetic interference is a concern for people wearing cardiovascular implantable electronic devices (CIEDs). The aim of this study was to assess the electromagnetic compatibility between CIEDs and the magnetic field of a common wireless charging technology. To do so the voltage induced in CIEDs by Qi A13 design magnetic fields were measured and compared with the performance limits set by ISO 14117. In order to carry this out a measuring circuit was developed which can be connected with unipolar or bipolar pacemaker leads. The measuring system was positioned at the four most common implantation sites in a torso phantom filled with physiological saline solution. The phantom was exposed by using Helmholtz coils from 5 µT to 27 µT with 111 kHz sine‑bursts or by using a Qi A13 design wireless charging board (Qi‑A13‑Board) in two operating modes "power transfer" and "pinging". With the Helmholtz coils the lowest magnetic flux density at which the performance limit was exceeded is 11 µT. With the Qi‑A13‑Board in power transfer mode 10.8% and in pinging mode 45.7% (2.2% at 10 cm distance) of the performance limit were reached at maximum. In neither of the scrutinized cases, did the voltage induced by the Qi‑A13‑Board exceed the performance limits.

  12. Design and Implementation of a Generic Energy-Harvesting Framework Applied to the Evaluation of a Large-Scale Electronic Shelf-Labeling Wireless Sensor Network

    Directory of Open Access Journals (Sweden)

    Kamerman Ad

    2010-01-01

    Full Text Available Most wireless sensor networks (WSNs consist of battery-powered nodes and are limited to hundreds of nodes. Battery replacement is a very costly operation and a key factor in limiting successful large-scale deployments. The recent advances in both energy harvesters and low-power communication systems hold promise for deploying large-scale wireless green-powered sensor networks (WGSNs. This will enable new applications and will eliminate environmentally unfriendly battery disposal. This paper explores the use of energy harvesters to scavenge power for nodes in a WSN. The design and implementation of a generic energy-harvesting framework, suited for a WSN simulator as well as a real-life testbed, are proposed. These frameworks are used to evaluate whether a carrier sense multiple access with collision avoidance scheme is sufficiently reliable for use in emerging large-scale energy harvesting electronic shelf label (EHESL systems (i.e., 12000 labels in a star topology. Both the simulator and testbed experiments yielded an average success rate up to 92%, with an arrival rate of 40 transceive cycles per second. We have demonstrated that our generic energy-harvesting framework is useful for WGSN research because the simulator allowed us to verify the achieved results on the real-life testbed and vice versa.

  13. From early wireless to Everest.

    Science.gov (United States)

    Allen, A

    1998-01-01

    Medical information has been transmitted using wireless technologies for almost 80 years. A "wired wireless" electronic stethoscope was developed by the U.S. Army Signal Corps in the early 1920's, for potential use in ship-to-shore transmission of cardiac sounds. [Winters SR. Diagnosis by wireless. Scientific American June 11, 1921, p. 465] Today, wireless is used in a wide range of medical applications and at sites from transoceanic air flights to offshore oil platforms to Mt. Everest. 'Wireless LANs' are often used in medical environments. Typically, nurses and physicians in a hospital or clinic use hand-held "wireless thin client" pen computers that exchange patient information and images with the hospital server. Numerous companies, such as Fujitsu (article below) and Cruise Technologies (www.cruisetech.com) manufacture handheld pen-entry computers. One company, LXE, integrates radio-frequency (RF) enhanced hand-held computers specifically designed for production use within a wireless LAN (www.lxe.com). Other companies (Proxim, Symbol, and others) supply the wireless RF LAN infrastructure for the enterprise. Unfortunately, there have been problems with widespread deployment of wireless LANs. Perhaps the biggest impediment has been the lack of standards. Although an international standard (IEEE 802.11) was adopted in 1997, most wireless LAN products still are not compatible with the equipment of competing companies. A problem with the current standard for LAN adapters is that throughput is limited to 3 Mbps--compared to at least 10 Mbps, and often 100 Mbps, in a hard-wired Ethernet LAN. An II Mbps standard is due out in the next year or so, but it will be at least 2 years before standards-compliant products are available. This story profiles some of the ways that wireless is being used to overcome gaps in terrestrial and within-enterprise communication.

  14. An on-chip programmable instrumentation microsystem for gastrointestinal telemetry applications.

    Science.gov (United States)

    Wang, Lei; Hammond, Paul; Johannesson, Erik; Tang, Tong Boon; Astaras, Alexandros; Cumming, David R S; Beaumont, Steve P; Murray, Alan F; Cooper, Jonathan M

    2004-01-01

    We have developed an integrated circuit microsystem instrument using a design methodology akin to that for system-on-chip microelectronics. The microsystem is optimised for low-power gastrointestinal telemetry applications and includes mixed-signal sensor circuits, programmable digital system, a feedback clock control loop and RF circuits that were integrated on a 5 mm x 5 mm silicon chip using a 0.6 microm, 3 V CMOS process. Unintended signal coupling between circuit components has been investigated and current injection into sensitive instrumentation nodes has been minimised. Tests show that the wireless instrument-on-chip worked as intended.

  15. A high speed multi-tasking, multi-processor telemetry system

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Kung Chris [Univ. of Texas, El Paso, TX (United States)

    1996-12-31

    This paper describes a small size, light weight, multitasking, multiprocessor telemetry system capable of collecting 32 channels of differential signals at a sampling rate of 6.25 kHz per channel. The system is designed to collect data from remote wind turbine research sites and transfer the data via wireless communication. A description of operational theory, hardware components, and itemized cost is provided. Synchronization with other data acquisition systems and test data on data transmission rates is also given. 11 refs., 7 figs., 4 tabs.

  16. An overview of acoustic telemetry

    Energy Technology Data Exchange (ETDEWEB)

    Drumheller, D.S.

    1992-01-01

    Acoustic telemetry has been a dream of the drilling industry for the past 50 years. It offers the promise of data rates which are one-hundred times greater than existing technology. Such a system would open the door to true logging-while-drilling technology and bring enormous profits to its developers. The basic idea is to produce an encoded sound wave at the bottom of the well, let it propagate up the steel drillpipe, and extract the data from the signal at the surface. Unfortunately, substantial difficulties arise. The first difficult problem is to produce the sound wave. Since the most promising transmission wavelengths are about 20 feet, normal transducer efficiencies are quire low. Compounding this problem is the structural complexity of the bottomhole assembly and drillstring. For example, the acoustic impedance of the drillstring changes every 30 feet and produces an unusual scattering pattern in the acoustic transmission. This scattering pattern causes distortion of the signal and is often confused with signal attenuation. These problems are not intractable. Recent work has demonstrated that broad frequency bands exist which are capable of transmitting data at rates up to 100 bits per second. Our work has also identified the mechanism which is responsible for the observed anomalies in the patterns of signal attenuation. Furthermore in the past few years a body of experience has been developed in designing more efficient transducers for application to metal waveguides. The direction of future work is clear. New transducer designs which are more efficient and compatible with existing downhole power supplies need to be built and tested; existing field test data need to be analyzed for transmission bandwidth and attenuation; and the new and less expensive methods of collecting data on transmission path quality need to be incorporated into this effort. 11 refs.

  17. Review of research methodologies for tigers: telemetry.

    Science.gov (United States)

    Miller, Clayton S; Hebblewhite, Mark; Goodrich, John M; Miquelle, Dale G

    2010-12-01

    Over the past half century, wildlife research has relied on technological advances to gain additional insight into the secretive lives of animals. This revolution started in the 1960s with the development of radio telemetry and continues today with the use of Global Positioning System (GPS)-based research techniques. In the present paper we review the history of radio telemetry from its origins with grizzly bears in Yellowstone to its early applications in tiger research and conservation in Asia. We address the different types of data that are available using radio telemetry as opposed to using other research techniques, such as behavioral observations, camera trapping, DNA analysis and scat analysis. In the late 1990s, the rapid development of GPS collar technology revolutionized wildlife research. This new technology has enabled researchers to dramatically improve their ability to gather data on animal movements and ecology. Despite the ecological and conservation benefits of radio telemetry, there have been few telemetry studies of tigers in the wild, and most have been on the Bengal or Amur subspecies. We close with an assessment of the current tiger conservation efforts using GPS technology and discuss how this new information can help to preserve tigers for future generations. © 2010 ISZS, Blackwell Publishing and IOZ/CAS.

  18. Control of Fan Blade Vibrations Using Piezoelectrics and Bi-Directional Telemetry

    Science.gov (United States)

    Provenza, Andrew J.; Morrison, Carlos R.

    2011-01-01

    A novel wireless device which transfers supply power through induction to rotating operational amplifiers and transmits low voltage AC signals to and from a rotating body by way of radio telemetry has been successfully demonstrated in the NASA Glenn Research Center (GRC) Dynamic Spin Test Facility. In the demonstration described herein, a rotating operational amplifier provides controllable AC power to a piezoelectric patch epoxied to the surface of a rotating Ti plate. The amplitude and phase of the sinusoidal voltage command signal, transmitted wirelessly to the amplifier, was tuned to completely suppress the 3rd bending resonant vibration of the plate. The plate's 3rd bending resonance was excited using rotating magnetic bearing excitation while it spun at slow speed in a vacuum chamber. A second patch on the opposite side of the plate was used as a sensor. This paper discusses the characteristics of this novel device, the details of a spin test, results from a preliminary demonstration, and future plans.

  19. A 100-Channel Hermetically Sealed Implantable Device for Chronic Wireless Neurosensing Applications

    Science.gov (United States)

    Yin, Ming; Borton, David A.; Aceros, Juan; Patterson, William R.; Nurmikko, Arto V.

    2014-01-01

    A 100-channel fully implantable wireless broadband neural recording system was developed. It features 100 parallel broadband (0.1 Hz–7.8 kHz) neural recording channels, a medical grade 200 mAh Li-ion battery recharged inductively at 150 kHz, and data telemetry using 3.2 GHz to 3.8 GHz FSK modulated wireless link for 48 Mbps Manchester encoded data. All active electronics are hermetically sealed in a titanium enclosure with a sapphire window for electromagnetic transparency. A custom, high-density configuration of 100 individual hermetic feedthrough pins enable connection to an intracortical neural recording microelectrode array. A 100 MHz bandwidth custom receiver was built to remotely receive the FSK signal and achieved −77.7 dBm sensitivity with 10−8 BER at 48 Mbps data rate. ESD testing on all the electronic inputs and outputs has proven that the implantable device satisfies the HBM Class-1B ESD Standard. In addition, the evaluation of the worst-case charge density delivered to the tissue from each I/O pin verifies the patient safety of the device in the event of failure. Finally, the functionality and reliability of the complete device has been tested on-bench and further validated chronically in ongoing freely moving swine and monkey animal trials for more than one year to date. PMID:23853294

  20. Using Onboard Telemetry for MAVEN Orbit Determination

    Science.gov (United States)

    Lam, Try; Trawny, Nikolas; Lee, Clifford

    2013-01-01

    Determination of the spacecraft state has been traditional done using radiometric tracking data before and after the atmosphere drag pass. This paper describes our approach and results to include onboard telemetry measurements in addition to radiometric observables to refine the reconstructed trajectory estimate for the Mars Atmosphere and Volatile Evolution Mission (MAVEN). Uncertainties in the Mars atmosphere models, combined with non-continuous tracking degrade navigation accuracy, making MAVEN a key candidate for using onboard telemetry data to help complement its orbit determination process.

  1. LP MOON MERGED TELEMETRY DATA V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — The Lunar Prospector merged telemetry data set is a result of comparing the two Lunar Prospector telemetry data streams and selecting one of them. The Lunar...

  2. 3D Display of Spacecraft Dynamics Using Real Telemetry

    Directory of Open Access Journals (Sweden)

    Sanguk Lee

    2002-12-01

    Full Text Available 3D display of spacecraft motion by using telemetry data received from satellite in real-time is described. Telemetry data are converted to the appropriate form for 3-D display by the real-time preprocessor. Stored playback telemetry data also can be processed for the display. 3D display of spacecraft motion by using real telemetry data provides intuitive comprehension of spacecraft dynamics.

  3. Telemetry Modernization with Open Architecture Software-Defined Radio Technology

    Science.gov (United States)

    2016-01-01

    Tech Notes January 2016www.ll.mit.edu Telemetry —the automated measurement and transmission of data from remote sources to receiving stations—plays... Telemetry Systems Ground-based telemetry systems have traditionally been implemented with special-purpose hardware components (e.g., analog...Each function in the telemetry signal chain is generally realized in a separate piece of equipment, so these systems have a large physical footprint

  4. 21 CFR 882.1855 - Electroencephalogram (EEG) telemetry system.

    Science.gov (United States)

    2010-04-01

    ... signals by means of radio or telephone transmission systems. (b) Classification. Class II (performance... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Electroencephalogram (EEG) telemetry system. 882... Electroencephalogram (EEG) telemetry system. (a) Identification. An electroencephalogram (EEG) telemetry system...

  5. Developing of a telemetry monitoring system for a solar vehicle

    Energy Technology Data Exchange (ETDEWEB)

    Taha, Z.; Passarella, R.; Sah, J.M.; Hui, H.X.; Ahmad, N.; Ghazilla, R.A.R.; Jen, Y.H.; Khai, T.T. [Malaya Univ., Kuala Lumpur (Malaysia). Faculty of Engineering, Centre for Product Design and Manufacture

    2009-07-01

    Researchers at the Centre for Product Design and Manufacture at the University of Malaya designed and built a solar car specifically for the 2009 World Solar Challenge (WSC). The features of the UniMalaya include 20 sensors that measure vibration, temperature, current and battery voltage. The research team must monitor the condition of the car and driver during the 3000 km race to ensure optimum performance of the solar vehicle and safety of the driver. The proposed telemetry monitoring system uses National Instruments' LabVIEW along with its programmable automation controller CompactRIO and a laptop computer. This paper described the configuration and programming of the hardware. A simple experiment was conducted to monitor simulated signals that represent sensors in the solar vehicle. The proposed monitoring system successfully monitored the real time condition of the solar vehicle. It was shown to be capable of acquiring and processing signals, data logging and sending out data with wireless. 6 refs., 13 figs.

  6. Downhole telemetry system reliability calculation and improvement

    Science.gov (United States)

    Trofimova, E. S.; Rubtsova, O. O.; Ishchenko, A. V.; Danilov, V. Yu.

    2017-09-01

    The article gives an estimation and a calculation of the reliability indexes for the downhole telemetry system downhole unit under severe operating conditions of high temperature environment. The reliability-growth methods are suggested. It is shown that the use of redundancy significantly extends mean time to failure even in high temperature environment.

  7. Eight-channel telephone telemetry system

    Science.gov (United States)

    Smith, R.; Carr, T.

    1973-01-01

    Portable telemetry system uses conventional telephone link which eliminates mailing or messenger service between physician and analyst. Transmitter is used by physician; receiver is used by analyst. Each unit is inductively coupled to its respective telephone set, transmitter converting EEG into audio frequency and receiver converting this frequency back to EEG.

  8. 106-17 Telemetry Standards Digitized Audio Telemetry Standard Chapter 5

    Science.gov (United States)

    2017-07-01

    system which accepts a band-limited analog signal and encodes it into binary form for transmission through a digital channel . At the receiver, the...bit code words. This nonlinear, sampled-data feedback system then transmits the encoded bit stream through a digital channel . At the receiving end...Telemetry Standards, RCC Standard 106-17 Chapter 5, July 2017 CHAPTER 5 Digitized Audio Telemetry Standard Table of Contents Chapter 5

  9. Get certified a guide to wireless communication engineering technologies

    CERN Document Server

    Ahson, Syed A

    2009-01-01

    The Institute of Electrical and Electronics Engineers (IEEE) Communications Society designed the IEEE wireless communication engineering technologies (WCET) certification program to address the wireless industry's growing need for communications professionals with practical problem-solving skills in real-world situations. Individuals who achieve this prestigious certification are recognized as possessing the required knowledge, skill, and abilities to meet wireless challenges in various industry, business, corporate, and organizational settings. Presenting contributions from 50 wireless commun

  10. Video electroencephalogram telemetry in temporal lobe epilepsy

    Directory of Open Access Journals (Sweden)

    Jayanti Mani

    2014-01-01

    Full Text Available Temporal lobe epilepsy (TLE is the most commonly encountered medically refractory epilepsy. It is also the substrate of refractory epilepsy that gives the most gratifying results in any epilepsy surgery program, with a minimum use of resources. Correlation of clinical behavior and the ictal patterns during ictal behavior is mandatory for success at epilepsy surgery. Video electroencephalogram (EEG telemetry achieves this goal and hence plays a pivotal role in pre-surgical assessment. The role of telemetry is continuously evolving with the advent of digital EEG technology, of high-resolution volumetric magnetic resonance imaging and other functional imaging techniques. Most of surgical selection in patients with TLE can be done with a scalp video EEG monitoring. However, the limitations of the scalp EEG technique demand invasive recordings in a selected group of TLE patients. This subset of the patients can be a challenge to the epileptologist.

  11. IOP telemetry in the nonhuman primate.

    Science.gov (United States)

    Downs, J Crawford

    2015-12-01

    This review is focused on continuous IOP monitoring using telemetry systems in the nonhuman primate (NHP), presented in the context that IOP fluctuations at various timescales may be involved in glaucoma pathogenesis and progression. We use glaucoma as the primary framework to discuss how the dynamic nature of IOP might change with age, racial heritage, and disease in the context of glaucoma susceptibility and progression. We focus on the limited work that has been published in IOP telemetry in NHPs, as well as the emerging data and approaches. We review the ongoing efforts to measure continuous IOP, and the strengths, weaknesses and general pitfalls of the various approaches. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Video telemetry: current concepts and recent advances.

    Science.gov (United States)

    Whittaker, R G

    2015-12-01

    Epilepsy is a clinical diagnosis based on the history of the patient and of witnesses. Sometimes this is not available or is incomplete, thus making diagnosis uncertain. In other cases, specifically in patients with intractable epilepsy being considered for epilepsy surgery, the diagnosis of epilepsy is not in doubt but the precise localisation of the epileptogenic zone needs to be determined. In both these situations, video telemetry plays a key role and is now a routine in most neuroscience units. This review covers existing practice and the exciting recent development of home video telemetry. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/

  13. A Systematic Approach to Error Free Telemetry

    Science.gov (United States)

    2017-06-28

    interference problem created by utilizing two antennas to transmit the same telemetry signal [8]. This has also been referred to as the “two antenna...selection, commonly called Best Source Selection (BSS). Up until recently there was not a robust method to assess link quality, time- align each source...and then choose the best source on a bit-by-bit basis. The key here is not the time alignment or the bit-by-bit selection, but the accurate

  14. Finding our way: On the sharing and reuse of animal telemetry data in Australasia

    Energy Technology Data Exchange (ETDEWEB)

    Campbell, Hamish A., E-mail: hamish.campbell@une.edu.au [Department of Ecosystem Management, School of Environment and Rural Sciences, University of New England, Armidale, NSW (Australia); Beyer, Hawthorne L. [ARC Centre of Excellence for Environmental Decisions, Centre for Biodiversity & Conservation Science, University of Queensland, Brisbane, QLD (Australia); Dennis, Todd E. [School of Biological Sciences, University of Auckland, Private Bag 92019, Auckland (New Zealand); Dwyer, Ross G. [School of Biological Sciences, University of Queensland, St Lucia, QLD (Australia); Forester, James D. [Dept. Fisheries, Wildlife, and Conservation Biology, University of Minnesota, St. Paul, MN (United States); Fukuda, Yusuke [Department of Land Resource Management, PO Box 496, Palmerston, NT (Australia); Lynch, Catherine [Arid Recovery, PO Box 147, Roxby Downs, SA (Australia); Hindell, Mark A. [University of Tasmania, Hobart, TAS (Australia); Menke, Norbert [Queensland Department of Science, Information, Technoloty, Innovation and the Arts, Brisbane, QLD (Australia); Morales, Juan M. [Ecotono, INIBIOMA—CONICET, Universidad Nacional del Comahue, Quintral 1250, 8400 Bariloche (Argentina); Richardson, Craig [Ecological Resources Information Network, Department of the Environment, Canberra, ACT (Australia); Rodgers, Essie [School of Biological Sciences, University of Queensland, St Lucia, QLD (Australia); Taylor, Graeme [Department of Conservation, PO Box 10420, Wellington 6143 (New Zealand); Watts, Matt E. [ARC Centre of Excellence for Environmental Decisions, Centre for Biodiversity & Conservation Science, University of Queensland, Brisbane, QLD (Australia); Westcott, David A. [Commonwealth Scientific and Industrial Research Organisation, PO Box 780, Atherton, QLD (Australia)

    2015-11-15

    The presence and movements of organisms both reflect and influence the distribution of ecological resources in space and time. The monitoring of animal movement by telemetry devices is being increasingly used to inform management of marine, freshwater and terrestrial ecosystems. Here, we brought together academics, and environmental managers to determine the extent of animal movement research in the Australasian region, and assess the opportunities and challenges in the sharing and reuse of these data. This working group was formed under the Australian Centre for Ecological Analysis and Synthesis (ACEAS), whose overall aim was to facilitate trans-organisational and transdisciplinary synthesis. We discovered that between 2000 and 2012 at least 501 peer-reviewed scientific papers were published that report animal location data collected by telemetry devices from within the Australasian region. Collectively, this involved the capture and electronic tagging of 12 656 animals. The majority of studies were undertaken to address specific management questions; rarely were these data used beyond their original intent. We estimate that approximately half (~ 500) of all animal telemetry projects undertaken remained unpublished, a similar proportion were not discoverable via online resources, and less than 8.8% of all animals tagged and tracked had their data stored in a discoverable and accessible manner. Animal telemetry data contain a wealth of information about how animals and species interact with each other and the landscapes they inhabit. These data are expensive and difficult to collect and can reduce survivorship of the tagged individuals, which implies an ethical obligation to make the data available to the scientific community. This is the first study to quantify the gap between telemetry devices placed on animals and findings/data published, and presents methods for improvement. Instigation of these strategies will enhance the cost-effectiveness of the research and

  15. Finding our way: On the sharing and reuse of animal telemetry data in Australasia

    International Nuclear Information System (INIS)

    Campbell, Hamish A.; Beyer, Hawthorne L.; Dennis, Todd E.; Dwyer, Ross G.; Forester, James D.; Fukuda, Yusuke; Lynch, Catherine; Hindell, Mark A.; Menke, Norbert; Morales, Juan M.; Richardson, Craig; Rodgers, Essie; Taylor, Graeme; Watts, Matt E.; Westcott, David A.

    2015-01-01

    The presence and movements of organisms both reflect and influence the distribution of ecological resources in space and time. The monitoring of animal movement by telemetry devices is being increasingly used to inform management of marine, freshwater and terrestrial ecosystems. Here, we brought together academics, and environmental managers to determine the extent of animal movement research in the Australasian region, and assess the opportunities and challenges in the sharing and reuse of these data. This working group was formed under the Australian Centre for Ecological Analysis and Synthesis (ACEAS), whose overall aim was to facilitate trans-organisational and transdisciplinary synthesis. We discovered that between 2000 and 2012 at least 501 peer-reviewed scientific papers were published that report animal location data collected by telemetry devices from within the Australasian region. Collectively, this involved the capture and electronic tagging of 12 656 animals. The majority of studies were undertaken to address specific management questions; rarely were these data used beyond their original intent. We estimate that approximately half (~ 500) of all animal telemetry projects undertaken remained unpublished, a similar proportion were not discoverable via online resources, and less than 8.8% of all animals tagged and tracked had their data stored in a discoverable and accessible manner. Animal telemetry data contain a wealth of information about how animals and species interact with each other and the landscapes they inhabit. These data are expensive and difficult to collect and can reduce survivorship of the tagged individuals, which implies an ethical obligation to make the data available to the scientific community. This is the first study to quantify the gap between telemetry devices placed on animals and findings/data published, and presents methods for improvement. Instigation of these strategies will enhance the cost-effectiveness of the research and

  16. Implantable physiologic controller for left ventricular assist devices with telemetry capability.

    Science.gov (United States)

    Asgari, Siavash S; Bonde, Pramod

    2014-01-01

    Rotary type left ventricular assist devices have mitigated the problem of durability associated with earlier pulsatile pumps and demonstrated improved survival. However, the compromise is the loss of pulsatility due to continuous flow and retained percutaneous driveline leading to increased mortality and morbidity. Lack of pulsatility is implicated in increased gastrointestinal bleeding, aortic incompetence, and diastolic hypertension. We present a novel, wirelessly powered, ultra-compact, implantable physiologic controller capable of running a left ventricular assist device in a pulsatile mode with wireless power delivery. The schematic of our system was laid out on a circuit board to wirelessly receive power and run a left ventricular assist device with required safety and backup measures. We have embedded an antenna and wireless network for telemetry. Multiple signal processing steps and controlling algorithm were incorporated. The controller was tested in in vitro and in vivo experiments. The controller drove left ventricular assist devices continuously for 2 weeks in an in vitro setup and in vivo without any failure. Our controller is more power efficient than the current Food and Drug Administration-approved left ventricular assist device controllers. When used with electrocardiography synchronization, the controller allowed on-demand customization of operation with instantaneous flow and revolutions per minute changes, resulting in a pulsatile flow with adjustable pulse pressure. Our test results prove the system to be remarkably safe, accurate, and efficient. The unique combination of wireless powering and small footprint makes this system an ideal totally implantable physiologic left ventricular assist device system. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  17. Wireless Ways: Business and Personal Applications of Wireless Technology.

    Science.gov (United States)

    Chung, Joe

    2001-01-01

    Describes the Art Technology Group (ATG), an electronic business and customer management company, and the work they have done with wireless technology. Highlights include designing virtual offices and supporting the resulting virtual community; the mobility it allows; problems with bandwidth; and display issues. (LRW)

  18. Interpretation of Space Shuttle telemetry

    Science.gov (United States)

    Culp, Donald R.

    1990-01-01

    This paper describes the Payload Deployment and Retrieval System (PDRS) Failure Analysis and Diagnosis problem, our planned use of an expert system employing the C Language Integrated Production System (CLIPS) language to solve it, and our progress to date. In addition, it will address the importance of the overall design within the context of automation in the RTDS architecture, the methodology used, and the validation approach taken. The Decision Support System will evolve as a modularized rule-based system programmed in the CLIPS expert system language. Each of five modules represents a subsystem of the RMS and includes the positioning and retention hardware (MPM/MRL), the Display & Control panel (D8C), the Arm Based Electronics (ABE), the End Effector (EE), and the Orbiter to RMS data interface unit (MCIU). The MPM/MRL subsystem was chosen as the target of a prototype development and its knowledge base is completed. Testing and validation of the software is conducted by experienced mission controllers. The initial design stages for the D&C panel module are beginning.

  19. A history of telemetry in fishery research: Chapter 2

    Science.gov (United States)

    Hockersmith, Eric; Beeman, John W.; Adams, Noah S.; Beeman, John W.; Eiler, John H.

    2012-01-01

    Telemetry provides a powerful and flexible tool for studying fish and other aquatic animals, and its use has become increasingly commonplace. However, telemetry is gear intensive and typically requires more specialized knowledge and training than many other field techniques. As with other scientific methods, collecting good data is dependent on an understanding of the underlying principles behind the approach, knowing how to use the equipment and techniques properly, and recognizing what to do with the data collected. This book provides a road map for using telemetry to study aquatic animals, and provides the basic information needed to plan, implement, and conduct a telemetry study under field conditions. Topics include acoustic or radio telemetry study design, tag implantation techniques, radio and acoustic telemetry principles and case studies, and data management and analysis.

  20. XTCE: XML Telemetry and Command Exchange Tutorial, XTCE Version 1

    Science.gov (United States)

    Rice, Kevin; Kizzort, Brad

    2008-01-01

    These presentation slides are a tutorial on XML Telemetry and Command Exchange (XTCE). The goal of XTCE is to provide an industry standard mechanism for describing telemetry and command streams (particularly from satellites.) it wiill lower cost and increase validation over traditional formats, and support exchange or native format.XCTE is designed to describe bit streams, that are typical of telemetry and command in the historic space domain.

  1. Application of harmonic detection technology in methane telemetry

    Science.gov (United States)

    Huo, Yuehua; Fan, Weiqiang

    2017-08-01

    Methane telemetry plays a vital role in ensuring the safe production of coal mines and monitoring the leakage of natural gas pipelines. Harmonic detection is the key technology of methane telemetry accuracy and sensitivity, but the current telemetry distance is short, the relationship between different modulation parameters is complex, and the harmonic signal is affected by noise interference. These factors seriously affect the development of harmonic detection technology. In this paper, the principle of methane telemetry based on harmonic detection technology is introduced. The present situation and characteristics of harmonic detection technology are expounded. The problems existing in harmonic detection are analyzed. Finally, the future development trend is discussed.

  2. Telemetry Boards Interpret Rocket, Airplane Engine Data

    Science.gov (United States)

    2009-01-01

    For all the data gathered by the space shuttle while in orbit, NASA engineers are just as concerned about the information it generates on the ground. From the moment the shuttle s wheels touch the runway to the break of its electrical umbilical cord at 0.4 seconds before its next launch, sensors feed streams of data about the status of the vehicle and its various systems to Kennedy Space Center s shuttle crews. Even while the shuttle orbiter is refitted in Kennedy s orbiter processing facility, engineers constantly monitor everything from power levels to the testing of the mechanical arm in the orbiter s payload bay. On the launch pad and up until liftoff, the Launch Control Center, attached to the large Vehicle Assembly Building, screens all of the shuttle s vital data. (Once the shuttle clears its launch tower, this responsibility shifts to Mission Control at Johnson Space Center, with Kennedy in a backup role.) Ground systems for satellite launches also generate significant amounts of data. At Cape Canaveral Air Force Station, across the Banana River from Kennedy s location on Merritt Island, Florida, NASA rockets carrying precious satellite payloads into space flood the Launch Vehicle Data Center with sensor information on temperature, speed, trajectory, and vibration. The remote measurement and transmission of systems data called telemetry is essential to ensuring the safe and successful launch of the Agency s space missions. When a launch is unsuccessful, as it was for this year s Orbiting Carbon Observatory satellite, telemetry data also provides valuable clues as to what went wrong and how to remedy any problems for future attempts. All of this information is streamed from sensors in the form of binary code: strings of ones and zeros. One small company has partnered with NASA to provide technology that renders raw telemetry data intelligible not only for Agency engineers, but also for those in the private sector.

  3. Telemetry and Science Data Software System

    Science.gov (United States)

    Bates, Lakesha; Hong, Liang

    2011-01-01

    The Telemetry and Science Data Software System (TSDSS) was designed to validate the operational health of a spacecraft, ease test verification, assist in debugging system anomalies, and provide trending data and advanced science analysis. In doing so, the system parses, processes, and organizes raw data from the Aquarius instrument both on the ground and while in space. In addition, it provides a user-friendly telemetry viewer, and an instant pushbutton test report generator. Existing ground data systems can parse and provide simple data processing, but have limitations in advanced science analysis and instant report generation. The TSDSS functions as an offline data analysis system during I&T (integration and test) and mission operations phases. After raw data are downloaded from an instrument, TSDSS ingests the data files, parses, converts telemetry to engineering units, and applies advanced algorithms to produce science level 0, 1, and 2 data products. Meanwhile, it automatically schedules upload of the raw data to a remote server and archives all intermediate and final values in a MySQL database in time order. All data saved in the system can be straightforwardly retrieved, exported, and migrated. Using TSDSS s interactive data visualization tool, a user can conveniently choose any combination and mathematical computation of interesting telemetry points from a large range of time periods (life cycle of mission ground data and mission operations testing), and display a graphical and statistical view of the data. With this graphical user interface (GUI), the data queried graphs can be exported and saved in multiple formats. This GUI is especially useful in trending data analysis, debugging anomalies, and advanced data analysis. At the request of the user, mission-specific instrument performance assessment reports can be generated with a simple click of a button on the GUI. From instrument level to observatory level, the TSDSS has been operating supporting

  4. Design of the Acoustic Signal Receiving Unit of Acoustic Telemetry While Drilling

    Directory of Open Access Journals (Sweden)

    Li Zhigang

    2016-01-01

    Full Text Available Signal receiving unit is one of the core units of the acoustic telemetry system. A new type of acoustic signal receiving unit is designed to solve problems of the existing devices. The unit is a short joint in whole. It not only can receive all the acoustic signals transmitted along the drill string, without losing any signal, but will not bring additional vibration and interference. In addition, the structure of the amplitude transformer is designed, which can amplify the signal amplitude and improve the receiving efficiency. The design of the wireless communication module makes the whole device can be used in normal drilling process when the drill string is rotating. So, it does not interfere with the normal drilling operation.

  5. Experimental Investigation of Cavitation Signatures in an Automotive Torque Converter Using a Microwave Telemetry Technique

    Directory of Open Access Journals (Sweden)

    C. L. Anderson

    2003-01-01

    Full Text Available A unique experimental investigation of cavitation signatures in an automotive torque converter under stall conditions is reported. A quantitative criterion is proposed for predicting early and advanced cavitation in terms of suitable nondimensional pump speeds. The dimensionless pump speed that marks early cavitation is obtained by relating this parameter to the appearance of charge-pressure–dependent pressure fluctuations in the differential pressure transducer readings. The differential pressure transducers were mounted at well-defined locations in the pump passage of a torque converter. The data were transmitted by a wireless telemetry system mounted on the pump housing. Data were received and processed by a ground-based data acquisition system. Automatic transmission fluid exhibited cavitation for charge pressures of 70–130 psi and pump speeds of 1000– 2250 rpm. Advanced cavitation was marked by operating conditions that exhibited a 2% or more torque degradation from the converter's noncavitating performance.

  6. Sonata: Query-Driven Network Telemetry

    KAUST Repository

    Gupta, Arpit

    2017-05-02

    Operating networks depends on collecting and analyzing measurement data. Current technologies do not make it easy to do so, typically because they separate data collection (e.g., packet capture or flow monitoring) from analysis, producing either too much data to answer a general question or too little data to answer a detailed question. In this paper, we present Sonata, a network telemetry system that uses a uniform query interface to drive the joint collection and analysis of network traffic. Sonata takes the advantage of two emerging technologies---streaming analytics platforms and programmable network devices---to facilitate joint collection and analysis. Sonata allows operators to more directly express network traffic analysis tasks in terms of a high-level language. The underlying runtime partitions each query into a portion that runs on the switch and another that runs on the streaming analytics platform iteratively refines the query to efficiently capture only the traffic that pertains to the operator\\'s query, and exploits sketches to reduce state in switches in exchange for more approximate results. Through an evaluation of a prototype implementation, we demonstrate that Sonata can support a wide range of network telemetry tasks with less state in the network, and lower data rates to streaming analytics systems, than current approaches can achieve.

  7. Bidirectional telemetry controller for neuroprosthetic devices.

    Science.gov (United States)

    Sharma, Vishnu; McCreery, Douglas B; Han, Martin; Pikov, Victor

    2010-02-01

    We present versatile multifunctional programmable controller with bidirectional data telemetry, implemented using existing commercial microchips and standard Bluetooth protocol, which adds convenience, reliability, and ease-of-use to neuroprosthetic devices. Controller, weighing 190 g, is placed on animal's back and provides bidirectional sustained telemetry rate of 500 kb/s , allowing real-time control of stimulation parameters and viewing of acquired data. In continuously-active state, controller consumes approximately 420 mW and operates without recharge for 8 h . It features independent 16-channel current-controlled stimulation, allowing current steering; customizable stimulus current waveforms; recording of stimulus voltage waveforms and evoked neuronal responses with stimulus artifact blanking circuitry. Flexibility, scalability, cost-efficiency, and a user-friendly computer interface of this device allow use in animal testing for variety of neuroprosthetic applications. Initial testing of the controller has been done in a feline model of brainstem auditory prosthesis. In this model, the electrical stimulation is applied to the array of microelectrodes implanted in the ventral cochlear nucleus, while the evoked neuronal activity was recorded with the electrode implanted in the contralateral inferior colliculus. Stimulus voltage waveforms to monitor the access impedance of the electrodes were acquired at the rate of 312 kilosamples/s. Evoked neuronal activity in the inferior colliculus was recorded after the blanking (transient silencing) of the recording amplifier during the stimulus pulse, allowing the detection of neuronal responses within 100 mus after the end of the stimulus pulse applied in the cochlear nucleus.

  8. Applicability of implantable telemetry systems in cardiovascular research.

    Science.gov (United States)

    Krutz, R. W.; Rader, R. D.; Meehan, J. P.; Henry, J. P.

    1971-01-01

    This paper briefly describes the results of an experimental program undertaken to develop and apply implanted telemetry to cardiovascular research. Because of the role the kidney may play in essential hypertension, emphasis is placed on telemetry's applicability in the study of renal physiology. Consequently, the relationship between pressure, flow, and hydraulic impedance are stressed. Results of an exercise study are given.

  9. Challenges and prospects in the telemetry of insects

    NARCIS (Netherlands)

    Kissling, W.D.; Pattemore, D.E.; Hagen, M.

    2014-01-01

    Radio telemetry has been widely used to study the space use and movement behaviour of vertebrates, but transmitter sizes have only recently become small enough to allow tracking of insects under natural field conditions. Here, we review the available literature on insect telemetry using active

  10. Tracking anguillid eels: five decades of telemetry-based research

    DEFF Research Database (Denmark)

    Beguer-Pon, Melanie; Dodson, Julian J.; Castonguay, Martin

    2018-01-01

    Advances in telemetry technologies have provided new opportunities to reveal the often-cryptic spatial ecology of anguillid eels. Herein we review 105 studies published between 1972 and 2016 that used a variety of telemetry technologies to study the movements of eels in a variety of habitats. Eig...

  11. Wireless roadside inspection phase II : final report : [technology brief].

    Science.gov (United States)

    2014-04-01

    The Federal Motor Carrier Safety Administration (FMCSA) Wireless Roadside Inspection (WRI) Program is demonstrating the feasibility and value of electronically assessing truck and motorcoach driver and vehicle safety. Electronic assessments (or WRIs)...

  12. Wireless sensor data acquisition on remote locations

    OpenAIRE

    Apat, Mark

    2010-01-01

    Systems for remote wireless acquisition of sensor data are an important field of technology which combines knowledge from computer science and electronics. Development of such systems is facilitated by wireless standards like ZigBee which improve and simplify such a development. This diploma thesis describes the design and realization of a ZigBee standard based system and the corresponding application for data acquisition and control of remote sensors. The system is capable of acquiring va...

  13. Telemetry system for monitoring anterior cruciate ligament graft forces in vivo

    Science.gov (United States)

    McKee, Eric L.; Hull, Maury L.; Howell, Stephen M.

    1997-02-01

    Quantifying changes in the tension of an anterior cruciate ligament (ACL) graft in vivo during rehabilitative exercises is vital for developing the optimal rehabilitation for patients who have had reconstructive surgery. The purpose of this project was to design, built, and test a telemetry system that can measure the in vivo ACL graft tension postoperatively. A commercially available fixation device was modified to sense the graft tension, house electronic components, transmit an output signal, and pass the power generating signal. A transcutaneous inductive link was used to power the implanted telemetry electronics. The current difference technique was used to measure changes in two strain gages that monitored shear strain developed on the femoral fixation device by the ACL graft. This current regulated a frequency modulated output signal and transmitted it, by using the ionic properties of body tissue as the medium, to external EMG surface electrodes. A signal conditioning board detected and converted the output to an analog voltage for collection by a computer data acquisition system. A performance evaluation demonstrated that the telemetry system either met or exceeded al of the criteria necessary for the application.

  14. Multi-purpose ECG telemetry system.

    Science.gov (United States)

    Marouf, Mohamed; Vukomanovic, Goran; Saranovac, Lazar; Bozic, Miroslav

    2017-06-19

    The Electrocardiogram ECG is one of the most important non-invasive tools for cardiac diseases diagnosis. Taking advantage of the developed telecommunication infrastructure, several approaches that address the development of telemetry cardiac devices were introduced recently. Telemetry ECG devices allow easy and fast ECG monitoring of patients with suspected cardiac issues. Choosing the right device with the desired working mode, signal quality, and the device cost are still the main obstacles to massive usage of these devices. In this paper, we introduce design, implementation, and validation of a multi-purpose telemetry system for recording, transmission, and interpretation of ECG signals in different recording modes. The system consists of an ECG device, a cloud-based analysis pipeline, and accompanied mobile applications for physicians and patients. The proposed ECG device's mechanical design allows laypersons to easily record post-event short-term ECG signals, using dry electrodes without any preparation. Moreover, patients can use the device to record long-term signals in loop and holter modes, using wet electrodes. In order to overcome the problem of signal quality fluctuation due to using different electrodes types and different placements on subject's chest, customized ECG signal processing and interpretation pipeline is presented for each working mode. We present the evaluation of the novel short-term recorder design. Recording of an ECG signal was performed for 391 patients using a standard 12-leads golden standard ECG and the proposed patient-activated short-term post-event recorder. In the validation phase, a sample of validation signals followed peer review process wherein two experts annotated the signals in terms of signal acceptability for diagnosis.We found that 96% of signals allow detecting arrhythmia and other signal's abnormal changes. Additionally, we compared and presented the correlation coefficient and the automatic QRS delineation results

  15. A Wireless Sensor Enabled by Wireless Power

    Science.gov (United States)

    Lee, Da-Sheng; Liu, Yu-Hong; Lin, Chii-Ruey

    2012-01-01

    Through harvesting energy by wireless charging and delivering data by wireless communication, this study proposes the concept of a wireless sensor enabled by wireless power (WPWS) and reports the fabrication of a prototype for functional tests. One WPWS node consists of wireless power module and sensor module with different chip-type sensors. Its main feature is the dual antenna structure. Following RFID system architecture, a power harvesting antenna was designed to gather power from a standard reader working in the 915 MHz band. Referring to the Modbus protocol, the other wireless communication antenna was integrated on a node to send sensor data in parallel. The dual antenna structure integrates both the advantages of an RFID system and a wireless sensor. Using a standard UHF RFID reader, WPWS can be enabled in a distributed area with a diameter up to 4 m. Working status is similar to that of a passive tag, except that a tag can only be queried statically, while the WPWS can send dynamic data from the sensors. The function is the same as a wireless sensor node. Different WPWSs equipped with temperature and humidity, optical and airflow velocity sensors are tested in this study. All sensors can send back detection data within 8 s. The accuracy is within 8% deviation compared with laboratory equipment. A wireless sensor network enabled by wireless power should be a totally wireless sensor network using WPWS. However, distributed WPWSs only can form a star topology, the simplest topology for constructing a sensor network. Because of shielding effects, it is difficult to apply other complex topologies. Despite this limitation, WPWS still can be used to extend sensor network applications in hazardous environments. Further research is needed to improve WPWS to realize a totally wireless sensor network. PMID:23443370

  16. A Wireless Sensor Enabled by Wireless Power

    Directory of Open Access Journals (Sweden)

    Da-Sheng Lee

    2012-11-01

    Full Text Available Through harvesting energy by wireless charging and delivering data by wireless communication, this study proposes the concept of a wireless sensor enabled by wireless power (WPWS and reports the fabrication of a prototype for functional tests. One WPWS node consists of wireless power module and sensor module with different chip-type sensors. Its main feature is the dual antenna structure. Following RFID system architecture, a power harvesting antenna was designed to gather power from a standard reader working in the 915 MHz band. Referring to the Modbus protocol, the other wireless communication antenna was integrated on a node to send sensor data in parallel. The dual antenna structure integrates both the advantages of an RFID system and a wireless sensor. Using a standard UHF RFID reader, WPWS can be enabled in a distributed area with a diameter up to 4 m. Working status is similar to that of a passive tag, except that a tag can only be queried statically, while the WPWS can send dynamic data from the sensors. The function is the same as a wireless sensor node. Different WPWSs equipped with temperature and humidity, optical and airflow velocity sensors are tested in this study. All sensors can send back detection data within 8 s. The accuracy is within 8% deviation compared with laboratory equipment. A wireless sensor network enabled by wireless power should be a totally wireless sensor network using WPWS. However, distributed WPWSs only can form a star topology, the simplest topology for constructing a sensor network. Because of shielding effects, it is difficult to apply other complex topologies. Despite this limitation, WPWS still can be used to extend sensor network applications in hazardous environments. Further research is needed to improve WPWS to realize a totally wireless sensor network.

  17. A wireless sensor enabled by wireless power.

    Science.gov (United States)

    Lee, Da-Sheng; Liu, Yu-Hong; Lin, Chii-Ruey

    2012-11-22

    Through harvesting energy by wireless charging and delivering data by wireless communication, this study proposes the concept of a wireless sensor enabled by wireless power (WPWS) and reports the fabrication of a prototype for functional tests. One WPWS node consists of wireless power module and sensor module with different chip-type sensors. Its main feature is the dual antenna structure. Following RFID system architecture, a power harvesting antenna was designed to gather power from a standard reader working in the 915 MHz band. Referring to the Modbus protocol, the other wireless communication antenna was integrated on a node to send sensor data in parallel. The dual antenna structure integrates both the advantages of an RFID system and a wireless sensor. Using a standard UHF RFID reader, WPWS can be enabled in a distributed area with a diameter up to 4 m. Working status is similar to that of a passive tag, except that a tag can only be queried statically, while the WPWS can send dynamic data from the sensors. The function is the same as a wireless sensor node. Different WPWSs equipped with temperature and humidity, optical and airflow velocity sensors are tested in this study. All sensors can send back detection data within 8 s. The accuracy is within 8% deviation compared with laboratory equipment. A wireless sensor network enabled by wireless power should be a totally wireless sensor network using WPWS. However, distributed WPWSs only can form a star topology, the simplest topology for constructing a sensor network. Because of shielding effects, it is difficult to apply other complex topologies. Despite this limitation, WPWS still can be used to extend sensor network applications in hazardous environments. Further research is needed to improve WPWS to realize a totally wireless sensor network.

  18. Telemetry Standards, RCC Standard 106-17. Chapter 3. Frequency Division Multiplexing Telemetry Standards

    Science.gov (United States)

    2017-07-01

    reference signal may be used as a detranslation frequency in a constant-bandwidth format. If the reference signal is recorded on a separate tape track...characteristics such as amplitude and phase nonlinearities of the transmitter, receiver, magnetic tape recorder /reproducer, or other system components...Telemetry Standards, RCC Standard 106-17 Chapter 3, July 2017 A-4 The use of magnetic tape recorders for recording a subcarrier multiplex may degrade the

  19. Telemetry Standards, RCC Standard 106-17. Chapter 9. Telemetry Attributes Transfer Standard

    Science.gov (United States)

    2017-07-01

    REVISION LEVEL G\\106 R/R Ch 10 Status: R Version of RCC IRIG 106 standard used to generate this TMATS file . The last 2 digits of the year...9-83 9.5.6 Digital Data Attributes (P, D, B, S) ............................................................. 9-90 9.5.7 Data Conversion...Telemetry Attributes Transfer Process ........................ A-2 Figure B-1. Sample Cover Sheet for Attribute Transfer Files

  20. Home Video Telemetry vs inpatient telemetry: A comparative study looking at video quality

    Directory of Open Access Journals (Sweden)

    Sutapa Biswas

    Full Text Available Objective: To compare the quality of home video recording with inpatient telemetry (IPT to evaluate our current Home Video Telemetry (HVT practice. Method: To assess our HVT practice, a retrospective comparison of the video quality against IPT was conducted with the latter as the gold standard. A pilot study had been conducted in 2008 on 5 patients.Patients (n = 28 were included in each group over a period of one year.The data was collected from referral spreadsheets, King’s EPR and telemetry archive.Scoring of the events captured was by consensus using two scorers.The variables compared included: visibility of the body part of interest, visibility of eyes, time of event, illumination, contrast, sound quality and picture clarity when amplified to 200%.Statistical evaluation was carried out using Shapiro–Wilk and Chi-square tests. The P-value of ⩽0.05 was considered statistically significant. Results: Significant differences were demonstrated in lighting and contrast between the two groups (HVT performed better in both.Amplified picture quality was slightly better in the HVT group. Conclusion: Video quality of HVT is comparable to IPT, even surpassing IPT in certain aspects such as the level of illumination and contrast. Results were reconfirmed in a larger sample of patients with more variables. Significance: Despite the user and environmental variability in HVT, it looks promising and can be seriously considered as a preferable alternative for patients who may require investigation at locations remote from an EEG laboratory. Keywords: Home Video Telemetry, EEG, Home video monitoring, Video quality

  1. Telemetry Standards, RCC Standard 106-17. Chapter 21. Telemetry Network Standard Introduction

    Science.gov (United States)

    2017-07-01

    the term “handoff” to describe this type of transition. Telemetry Standards, RCC Standard 106-17 Chapter 21, July 2017 21-3 • Over-the- Horizon ...model FCAPS, which stands for fault, configuration, accounting , performance, and security. System management is used across a TmNS system to manage...TmNS-compliant components, providing a view of fault, configuration, accounting , performance, and security configuration information on the network

  2. Telemetry and Communication IP Video Player

    Science.gov (United States)

    OFarrell, Zachary L.

    2011-01-01

    Aegis Video Player is the name of the video over IP system for the Telemetry and Communications group of the Launch Services Program. Aegis' purpose is to display video streamed over a network connection to be viewed during launches. To accomplish this task, a VLC ActiveX plug-in was used in C# to provide the basic capabilities of video streaming. The program was then customized to be used during launches. The VLC plug-in can be configured programmatically to display a single stream, but for this project multiple streams needed to be accessed. To accomplish this, an easy to use, informative menu system was added to the program to enable users to quickly switch between videos. Other features were added to make the player more useful, such as watching multiple videos and watching a video in full screen.

  3. Adaptive Wireless Transceiver Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Many wireless technologies are already available for sensor applications. It is inevitable that many non-interoperable wireless technologies between 400 MHz and 5.8...

  4. Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor.

    Science.gov (United States)

    Arakawa, Takahiro; Kuroki, Yusuke; Nitta, Hiroki; Chouhan, Prem; Toma, Koji; Sawada, Shin-Ichi; Takeuchi, Shuhei; Sekita, Toshiaki; Akiyoshi, Kazunari; Minakuchi, Shunsuke; Mitsubayashi, Kohji

    2016-10-15

    We develop detachable "Cavitas sensors" to apply to the human oral cavity for non-invasive monitoring of saliva glucose. A salivary biosensor incorporating Pt and Ag/AgCl electrodes on a mouthguard support with an enzyme membrane is developed and tested. Electrodes are formed on the polyethylene terephthalate glycol (PETG) surface of the mouthguard. The Pt working electrode is coated with a glucose oxidase (GOD) membrane. The biosensor seamlessly is integrated with a glucose sensor and a wireless measurement system. When investigating in-vitro performance, the biosensor exhibits a robust relationship between output current and glucose concentration. In artificial saliva composed of salts and proteins, the glucose sensor is capable of highly sensitive detection over a range of 5-1000µmol/L of glucose, which encompasses the range of glucose concentrations found in human saliva. We demonstrate the ability of the sensor and wireless communication module to monitor saliva glucose in a phantom jaw imitating the structure of the human oral cavity. Stable and long-term real-time monitoring (exceeding 5h) with the telemetry system is achieved. The mouthguard biosensor will be useful as a novel method for real-time non-invasive saliva glucose monitoring for better management of dental patients. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Lossless Compression of Telemetry Information using Adaptive Linear Prediction

    Directory of Open Access Journals (Sweden)

    M. A. Elshafey

    2014-01-01

    Full Text Available Normal requirement for telemetry data compression algorithms is an ability to recover initial data “as is” without loss of information. This feature is very important in various telemetry processing applications. Precise recovery of the telemetry data as it is acquired from the original source of information is necessary for the analysis of any kind of abnormal events, recovery of bad sites within the telemetry data stream and for other types of post- or real-time data processing [1,2]. The effectiveness of methods of lossless compression is largely determined by the properties of the data under compression [3]. Compression algorithms show better compression ratios if they can adapt to the characteristics of the input data, which are in most cases rapidly change. In this paper we present the results of studies conducted to develop an efficient method of reversible telemetry data compression based on adaptive linear prediction of telemetry data packed according to IRIG-106 format. IRIG-106 is an open standard, developed specifically for aerospace industry, but now used in wide range of telemetry registration applications [4]. Data is packed to frames of fixed length and predefined internal structure. Frame can carry different sources of information: digitized samples of analog signals, as well as pure digital data. For each source a channel of the recording system is provided. The source sample in each channel is introduced by telemetry word. All words in the frame have the same bit width. Telemetry frame contains additional service information in purpose of detecting bit errors, frame synchronization, etc.Lossless data compression algorithm can be divided into two stages; the first stage - decorrelation stage, which exploits the redundancy between the neighboring samples in the data sequence, the second stage - entropy coding, which takes advantage from decreasing variance and lowering entropy of the data made on the first stage [5,6,7].

  6. Simulation of Wireless Digital Communication Systems

    Directory of Open Access Journals (Sweden)

    A. Mohammed

    2004-12-01

    Full Text Available Due to the explosive demands for high speed wireless services, suchas wireless Internet, email and cellular video conferencing, digitalwireless communications has become one of the most exciting researchtopics in electrical and electronic engineering field. The never-endingdemand for such personal and multimedia services, however, demandstechnologies operating at higher data rates and broader bandwidths. Inaddition, the complexity of wireless communication and signalprocessing systems has grown considerably during the past decade.Therefore, powerful computer­aided techniques are required for theprocess of modeling, designing, analyzing and evaluating theperformance of digital wireless communication systems. In this paper wediscuss the basic propagation mechanisms affecting the performance ofwireless communication systems, and present a simple, powerful andefficient way to simulate digital wireless communication systems usingMatlab. The simulated results are compared with the theoreticalanalysis to validate the simulator. The simulator is useful inevaluating the performance of wireless multimedia services and theassociated signal processing structures and algorithms for current andnext generation wireless mobile communication systems.

  7. Wireless Communication Technologies

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Wireless Communication Technologies. Since 1999, the wireless LAN has experienced a tremendous growth. Reasons: Adoption of industry standards. Interoperability testing. The progress of wireless equipments to higher data rates. Rapid decrease in product ...

  8. The design of visualization telemetry system based on camera module of the commercial smartphone

    Science.gov (United States)

    Wang, Chao; Ye, Zhao; Wu, Bin; Yin, Huan; Cao, Qipeng; Zhu, Jun

    2017-09-01

    Satellite telemetry is the vital indicators to estimate the performance of the satellite. The telemetry data, the threshold range and the variation tendency collected during the whole operational life of the satellite, can guide and evaluate the subsequent design of the satellite in the future. The rotational parts on the satellite (e.g. solar arrays, antennas and oscillating mirrors) affect collecting the solar energy and the other functions of the satellite. Visualization telemetries (pictures, video) are captured to interpret the status of the satellite qualitatively in real time as an important supplement for troubleshooting. The mature technology of commercial off-the-shelf (COTS) products have obvious advantages in terms of the design of construction, electronics, interfaces and image processing. Also considering the weight, power consumption, and cost, it can be directly used in our application or can be adopted for secondary development. In this paper, characteristic simulations of solar arrays radiation in orbit are presented, and a suitable camera module of certain commercial smartphone is adopted after the precise calculation and the product selection process. Considering the advantages of the COTS devices, which can solve both the fundamental and complicated satellite problems, this technique proposed is innovative to the project implementation in the future.

  9. Low-Power Wireless Sensor Network Infrastructures

    DEFF Research Database (Denmark)

    Hansen, Morten Tranberg

    Advancements in wireless communication and electronics improving form factor and hardware capabilities has expanded the applicability of wireless sensor networks. Despite these advancements, devices are still limited in terms of energy which creates the need for duty-cycling and low-power protocols...... peripherals need to by duty-cycled and the low-power wireless radios are severely influenced by the environmental effects causing bursty and unreliable wireless channels. This dissertation presents a communication stack providing services for low-power communication, secure communication, data collection...... channel. Second, secure communication is implemented with an efficient secure group communication suite including a low-overhead group key distribution scheme, distributing group keys according to the needs of the sensor nodes. Third, data collection is implemented with selective transmission which saves...

  10. Wireless pilot monitoring system for extreme race conditions.

    Science.gov (United States)

    Pino, Esteban J; Arias, Diego E; Aqueveque, Pablo; Melin, Pedro; Curtis, Dorothy W

    2012-01-01

    This paper presents the design and implementation of an assistive device to monitor car drivers under extreme conditions. In particular, this system is designed in preparation for the 2012 Atacama Solar Challenge to be held in the Chilean desert. Actual preliminary results show the feasibility of such a project including physiological and ambient sensors, real-time processing algorithms, wireless data transmission and a remote monitoring station. Implementation details and field results are shown along with a discussion of the main problems found in real-life telemetry monitoring.

  11. CASSINI S INMS TELEMETRY PACKET DATA V1.0

    Data.gov (United States)

    National Aeronautics and Space Administration — The Cassini Ion and Neutral Mass Spectrometer (INMS) Packet data set contains all telemetry packets as received from the instrument. One standard product data type...

  12. Liquid Robotics Wave Glider, Honey Badger (G3), 2015, Telemetry

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Liquid Robotics Wave Glider, Honey Badger (G3), 2015, Telemetry. The MAGI mission is to use the Wave Glider to sample the late summer chlorophyll bloom that develops...

  13. Telemetry correlation and visualization at the Large Binocular Telescope Observatory

    Science.gov (United States)

    Summers, Kellee R.; Summers, Douglas M.; Biddick, Christopher; Hooper, Stephen

    2016-08-01

    To achieve highly efficient observatory operations requires continuous evaluation and improvement of facility and instrumentation metrics. High quality metrics requires a foundation of robust and complete observatory telemetry. At the Large Binocular Telescope Observatory (LBTO), a variety of telemetry-capturing mechanisms exist, but few tools have thus far been created to facilitate studies of the data. In an effort to make all observatory telemetry data easy to use and broadly available, we have developed a suite of tools using in-house development and open source applications. This paper will explore our strategies for consolidating, parameterizing, and correlating any LBTO telemetry data to achieve easily available, web-based two- and three-dimensional time series data visualization.

  14. High Temperature Telemetry Transmitter for Venus Exploration Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed S-band telemetry transmitter will operate in the exterior Venusian corrosive, high pressure, 460oC ambient atmosphere without being contained in a...

  15. High Temperature Telemetry Transmitter for Venus Exploration Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed S-band telemetry transmitter will operate in the exterior Venusian high pressure, 465?aC ambient atmosphere without being contained in a thermally...

  16. High Temperature Telemetry Transmitter for Venus Exploration, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed S-band telemetry transmitter will operate in the exterior Venusian corrosive, high pressure, 460oC ambient atmosphere without being contained in a...

  17. High Temperature Telemetry Transmitter for Venus Exploration, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed S-band telemetry transmitter will operate in the exterior Venusian high pressure, 465?aC ambient atmosphere without being contained in a thermally...

  18. Electric smog: telemetry interference between ICD and LVAD.

    Science.gov (United States)

    Duncker, David; König, Thorben; Müller-Leisse, Johanna; Michalski, Roman; Oswald, Hanno; Schmitto, Jan D; Bauersachs, Johann; Veltmann, Christian

    2017-09-01

    Electromagnetic interferences between implantable cardioverter/defibrillators (ICD) and left ventricular assist devices (LVAD) impacting telemetry have been described in previous generations of ICD as well as LVAD, but have been predominantly overcome in current ICD generations. After introduction of a new fully magnetically levitated centrifugal continuous-flow circulatory pump, we report a case of tenacious telemetry interference between the HeartMate 3 LVAD and an ICD after battery exchange to an Iforia 5. Initialization of the initial telemetry handshake was only possible using several specific maneuvers simultaneously. In order to exclude device-device interference, we suggest to place the ICD above the LVAD before implantation and to test for possible telemetry interferences.

  19. The Economic Importance of Adequate Aeronautical Telemetry Spectrum

    National Research Council Canada - National Science Library

    Kahn, Carolyn A

    2005-01-01

    INTRODUCTION: (1) The flight test community faces a telemetry spectrum crunch; (2) Amount of spectrum now allocated for ATM is not sufficient to meet needs, and requirements have been steadily growing...

  20. 106-17 Telemetry Management Resources Chapter 25

    Science.gov (United States)

    2017-07-01

    capable of generating event -based notifications. Management resources regarding general notifications are contained within the...Telemetry Standards, RCC Standard 106-17 Chapter 25, July 2017 i CHAPTER 25 Management Resources Acronyms...iii Chapter 25. Management Resources

  1. CCNA Wireless Study Guide

    CERN Document Server

    Lammle, Todd

    2010-01-01

    A complete guide to the CCNA Wireless exam by leading networking authority Todd Lammle. The CCNA Wireless certification is the most respected entry-level certification in this rapidly growing field. Todd Lammle is the undisputed authority on networking, and this book focuses exclusively on the skills covered in this Cisco certification exam. The CCNA Wireless Study Guide joins the popular Sybex study guide family and helps network administrators advance their careers with a highly desirable certification.: The CCNA Wireless certification is the most respected entry-level wireless certification

  2. Design issues and applications of wireless sensor networks ...

    African Journals Online (AJOL)

    ... using tiny wireless sensor motes known as “smart dusts”, which have been made possible by advances in micro-electromechanical systems (MEMS) technology, wireless communications and digital electronics. Design considerations for the hardware and the topology necessary to realize these networks were evaluated.

  3. Aquatic animal telemetry: A panoramic window into the underwater world

    DEFF Research Database (Denmark)

    Hussey, Nigel E.; Kessel, Steven T.; Aarestrup, Kim

    2015-01-01

    The distribution and interactions of aquatic organisms across space and time structure our marine, freshwater, and estuarine ecosystems. Over the past decade, technological advances in telemetry have transformed our ability to observe aquatic animal behavior and movement. These advances are now...... individuals, populations, and entire ecosystems. The next advance in aquatic telemetry will be the development of a global collaborative effort to facilitate infrastructure and data sharing and management over scales not previously possible....

  4. Effect of a Nurse-Managed Telemetry Discontinuation Protocol on Monitoring Duration, Alarm Frequency, and Adverse Patient Events.

    Science.gov (United States)

    Perrin, Keisha; Ernst, Neysa; Nelson, Terry; Sawyer, Melinda; Pfoh, Elizabeth; Cvach, Maria

    Telemetry monitoring is a limited resource. This quality improvement project describes a nurse-managed telemetry discontinuation protocol aimed at stopping telemetry monitoring when it is no longer indicated. After implementing the protocol, data were collected for 6 months and compared with a preintervention time frame. There was a mean decrease in telemetry monitor usage and a decreased likelihood of remaining on a telemetry monitor until discharge. A nurse-managed telemetry discontinuation protocol was effective in decreasing overmonitoring and ensuring telemetry availability.

  5. Comprehension of Spacecraft Telemetry Using Hierarchical Specifications of Behavior

    Science.gov (United States)

    Havelund, Klaus; Joshi, Rajeev

    2014-01-01

    A key challenge in operating remote spacecraft is that ground operators must rely on the limited visibility available through spacecraft telemetry in order to assess spacecraft health and operational status. We describe a tool for processing spacecraft telemetry that allows ground operators to impose structure on received telemetry in order to achieve a better comprehension of system state. A key element of our approach is the design of a domain-specific language that allows operators to express models of expected system behavior using partial specifications. The language allows behavior specifications with data fields, similar to other recent runtime verification systems. What is notable about our approach is the ability to develop hierarchical specifications of behavior. The language is implemented as an internal DSL in the Scala programming language that synthesizes rules from patterns of specification behavior. The rules are automatically applied to received telemetry and the inferred behaviors are available to ground operators using a visualization interface that makes it easier to understand and track spacecraft state. We describe initial results from applying our tool to telemetry received from the Curiosity rover currently roving the surface of Mars, where the visualizations are being used to trend subsystem behaviors, in order to identify potential problems before they happen. However, the technology is completely general and can be applied to any system that generates telemetry such as event logs.

  6. ZigBee-Based Telemetry System

    Directory of Open Access Journals (Sweden)

    L. Khriji

    2010-12-01

    Full Text Available Nowadays, there is a significant improvement in technology regarding healthcare. Real-time monitoring systems improve the quality of life of patients as well as the performance of hospitals and healthcare centers. In this paper, we present an implementation of a designed framework of a telemetry system using ZigBee technology for automatic and real-time monitoring of Biomedical signals. These signals are collected and processed using 2-tiered subsystems. The first subsystem is the mobile device which is carried on the body and runs a number of biosensors. The second subsystem performs further processing by a local base station using the raw data which is transmitted on-request by the mobile device. The processed data as well as its analysis are then continuously monitored and diagnosed through a human-machine interface. The system should possess low power consumption, low cost and advanced configuration possibilities. This paper accelerates the digital convergence age through continual research and development of technologies related to healthcare.

  7. Telemetry experiments with a hibernating black bear

    Science.gov (United States)

    Craighead, J. J.; Varney, J. R.; Sumner, J. S.; Craighead, F. C., Jr.

    1972-01-01

    The objectives of this research were to develop and test telemetry equipment suitable for monitoring physiological parameters and activity of a hibernating bear in its den, to monitor this data and other environmental information with the Nimbus 3 IRLS data collection system, and to refine immobilizing, handling, and other techniques required in future work with wild bears under natural conditions. A temperature-telemetering transmitter was implanted in the abdominal cavity of a captive black bear and body temperature data was recorded continuously during a 3 month hibernation period. Body temperatures ranging between 37.5 and 31.8 C were observed. Body temperature and overall activity were influenced by disturbances and ambient den temperature. Nychthemeral temperature changes were not noticable. A load cell weight recording device was tested for determining weight loss during hibernation. Monitoring of data by satellite was not attempted. The implanted transmitter was removed and the bear was released with a radiolocation collar at the conclusion of the experiment.

  8. ECG telemetry in conscious guinea pigs.

    Science.gov (United States)

    Ruppert, Sabine; Vormberge, Thomas; Igl, Bernd-Wolfgang; Hoffmann, Michael

    2016-01-01

    During preclinical drug development, monitoring of the electrocardiogram (ECG) is an important part of cardiac safety assessment. To detect potential pro-arrhythmic liabilities of a drug candidate and for internal decision-making during early stage drug development an in vivo model in small animals with translatability to human cardiac function is required. Over the last years, modifications/improvements regarding animal housing, ECG electrode placement, and data evaluation have been introduced into an established model for ECG recordings using telemetry in conscious, freely moving guinea pigs. Pharmacological validation using selected reference compounds affecting different mechanisms relevant for cardiac electrophysiology (quinidine, flecainide, atenolol, dl-sotalol, dofetilide, nifedipine, moxifloxacin) was conducted and findings were compared with results obtained in telemetered Beagle dogs. Under standardized conditions, reliable ECG data with low variability allowing largely automated evaluation were obtained from the telemetered guinea pig model. The model is sensitive to compounds blocking cardiac sodium channels, hERG K(+) channels and calcium channels, and appears to be even more sensitive to β-blockers as observed in dogs at rest. QT interval correction according to Bazett and Sarma appears to be appropriate methods in conscious guinea pigs. Overall, the telemetered guinea pig is a suitable model for the conduct of early stage preclinical ECG assessment. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. High capacity wireless data links in the W-band using hybrid photonics-electronic techniques for signal generation and detection

    DEFF Research Database (Denmark)

    Vegas Olmos, Juan José; Tafur Monroy, Idelfonso

    2014-01-01

    , is seeding the need to use bands located at the millimeter-wave region (30–300 GHz), mainly because of its inherent broadband nature. In our lab, we have conducted extensive research on high-speed photonic-wireless links in the V-band (50–75GHz) and the W-band (75–110GHz). In this paper, we will present our...... latest findings and experimental results on the W-band, specifically on its 81–86GHz sub-band. These include photonic generation of millimeter-wave carriers and transmission performance of broadband signals on different types of fibers and span lengths....

  10. Automatic Satellite Telemetry Analysis for SSA using Artificial Intelligence Techniques

    Science.gov (United States)

    Stottler, R.; Mao, J.

    In April 2016, General Hyten, commander of Air Force Space Command, announced the Space Enterprise Vision (SEV) (http://www.af.mil/News/Article-Display/Article/719941/hyten-announces-space-enterprise-vision/). The SEV addresses increasing threats to space-related systems. The vision includes an integrated approach across all mission areas (communications, positioning, navigation and timing, missile warning, and weather data) and emphasizes improved access to data across the entire enterprise and the ability to protect space-related assets and capabilities. "The future space enterprise will maintain our nation's ability to deliver critical space effects throughout all phases of conflict," Hyten said. Satellite telemetry is going to become available to a new audience. While that telemetry information should be valuable for achieving Space Situational Awareness (SSA), these new satellite telemetry data consumers will not know how to utilize it. We were tasked with applying AI techniques to build an infrastructure to process satellite telemetry into higher abstraction level symbolic space situational awareness and to initially populate that infrastructure with useful data analysis methods. We are working with two organizations, Montana State University (MSU) and the Air Force Academy, both of whom control satellites and therefore currently analyze satellite telemetry to assess the health and circumstances of their satellites. The design which has resulted from our knowledge elicitation and cognitive task analysis is a hybrid approach which combines symbolic processing techniques of Case-Based Reasoning (CBR) and Behavior Transition Networks (BTNs) with current Machine Learning approaches. BTNs are used to represent the process and associated formulas to check telemetry values against anticipated problems and issues. CBR is used to represent and retrieve BTNs that represent an investigative process that should be applied to the telemetry in certain circumstances

  11. Recording EEG in immature rats with a novel miniature telemetry system

    Science.gov (United States)

    Zayachkivsky, A.; Lehmkuhle, M. J.; Fisher, J. H.; Ekstrand, J. J.

    2013-01-01

    Serial EEG recordings from immature rat pups are extremely difficult to obtain but important for analyzing animal models of neonatal seizures and other pediatric neurological conditions as well as normal physiology. In this report, we describe the features and applications of a novel miniature telemetry system designed to record EEG in rat pups as young as postnatal day 6 (P6). First, we have recorded electrographic seizure activity in two animal models of neonatal seizures, hypoxia- and kainate-induced seizures at P7. Second, we describe a viable approach for long-term continuous EEG monitoring of naturally reared rat pups implanted with EEG at P6. Third, we have used serial EEG recordings to record age-dependent changes in the background EEG signal as the animals matured from P7 to P11. The important advantages of using miniature wireless EEG technology are: 1) minimally invasive surgical implantation; 2) a device form-factor that is compatible with housing of rat pups with the dam and littermates; 3) serial recordings of EEG activity; and 4) low power consumption of the unit, theoretically allowing continuous monitoring for up to 2 yr without surgical reimplantation. The miniature EEG telemetry system provides a technical advance that allows researchers to record continuous and serial EEG recordings in neonatal rodent models of human neurological disorders, study the progression of the disease, and then assess possible therapies using quantitative EEG as an outcome measure. This new technical approach should improve animal models of human conditions that rely on EEG monitoring for diagnosis and therapy. PMID:23114207

  12. Wireless physical layer security

    OpenAIRE

    Poor, H. Vincent; Schaefer, Rafael F.

    2016-01-01

    Security is a very important issue in the design and use of wireless networks. Traditional methods of providing security in such networks are impractical for some emerging types of wireless networks due to the light computational abilities of some wireless devices [such as radio-frequency identification (RFID) tags, certain sensors, etc.] or to the very large scale or loose organizational structure of some networks. Physical layer security has the potential to address these concerns by taking...

  13. Wireless security in mobile health.

    Science.gov (United States)

    Osunmuyiwa, Olufolabi; Ulusoy, Ali Hakan

    2012-12-01

    Mobile health (m-health) is an extremely broad term that embraces mobile communication in the health sector and data packaging. The four broad categories of wireless networks are wireless personal area network, wireless metropolitan area network, wireless wide area network, and wireless local area network. Wireless local area network is the most notable of the wireless networking tools obtainable in the health sector. Transfer of delicate and critical information on radio frequencies should be secure, and the right to use must be meticulous. This article covers the business opportunities in m-health, threats faced by wireless networks in hospitals, and methods of mitigating these threats.

  14. Wireless Emulation Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Wireless Emulation Laboratory (WEL) is a researchtest bed used to investigate fundamental issues in networkscience. It is a research infrastructure that emulates...

  15. Adaptive Wireless Transceiver Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Wireless technologies are an increasingly attractive means for spatial data, input, manipulation, and distribution. Mobitrum is proposing an innovative Adaptive...

  16. Wireless Telemetry of In-Flight Collision Avoidance Neural Signals in Insects

    Science.gov (United States)

    2010-09-01

    Collision-sensitive neurons in the optic tectum of the bulfrog ( rana catesbeiana ). Int. Congr. Series 1291, 145–148. Killmann, F. and Schurmann, F...Yamamoto, K., Nakata, M. and Nakagawa, H. (2003). Input and output characteristics of collision avoidance behavior in the frog rana catesbeiana . Brain

  17. Development and testing of an unmanned air vehicle telemetry system

    Science.gov (United States)

    Wilhelm, Kevin T.

    1991-09-01

    Unmanned air vehicles (UAV's) provide a low-cost, low-maintenance, and effective platform upon which experimentation can be performed to validate conceptual aerodynamic ideas. However, the UAV flight test data acquisition process is complex and requires a reliable recording system for post-flight data analysis. The thrust of this thesis was the development, construction, and validation of a viable telemetry system for data gathering and processing. Major areas of focus were: integration of the telemetry into a 1/8 scale model, radio controlled F-16A airplane; telemetry circuitry optimization; recording and display of instrumented parameters; and data reduction techniques necessary to obtain useful information. A flight test was flown and data was gathered using a steady-heading side-slip maneuver to demonstrate successful integration of all supporting elements.

  18. Kısa Mesafe RF Algılayıcı ile Telemetri Uygulaması

    Directory of Open Access Journals (Sweden)

    Muhammet Sinan BAŞARSLAN

    2016-03-01

    Full Text Available Bu çalışmada, Telemetri bir sistem ya da tesisin, uzaktan kablo veya kablosuz olarak izlenmesi ve/veya kontrol edilmesidir. Uygulama alanları olarak petrol, su veya gaz boru hatlarının izlenmesi, uydu ve telekom antenlerinin izlenmesi, içme veya atık su tesislerinin izlenmesi sayılabilir. Günümüzde çoğunlukla kablosuz (wireless haberleşme tercih edilmektedir. Kablosuz iletişim teknolojilerinden de en yaygın kullanılanları bluetooth, radyo modem cihazları, GSM sistemleridir.Haberleşme yapılacak olan arazi düz olmak zorunda değildir. Antenler arasında dağ, tepe vb. haberleşmeyi engelleyici unsurlar olsa bile repeater özellikli RF data modemler ile bu tür engeller aşılabilmektedir. Bu sayede noktalar arası uzaklıklar kilometrelerce olabilir.Sunulan uygulamada telemetri yöntemi ile bir model araca dair verilerin uzak bir noktada bulunan Android işletim sistemli bir mobil cihaz üzerinden izlenmesi gerçekleştirilmiştir. Uzaktan izleme işlemleri için kısa mesafe RF teknolojisi (433 MHz kullanılmıştır.

  19. Wireless mobile Internet security

    CERN Document Server

    Rhee, Man Young

    2013-01-01

      The mobile industry for wireless cellular services has grown at a rapid pace over the past decade. Similarly, Internet service technology has also made dramatic growth through the World Wide Web with a wire line infrastructure. Realization for complete wired/wireless mobile Internet technologies will become the future objectives for convergence of these technologies thr

  20. A Web-Based Airborne Remote Sensing Telemetry Server, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A Web-based Airborne Remote Sensing Telemetry Server (WARSTS) is proposed to integrate UAV telemetry and web-technology into an innovative communication, command,...

  1. Bluetooth low energy: wireless connectivity for medical monitoring.

    Science.gov (United States)

    Omre, Alf Helge

    2010-03-01

    Electronic wireless sensors could cut medical costs by enabling physicians to remotely monitor vital signs such as blood pressure, blood glucose, and blood oxygenation while patients remain at home. According to the IDC report "Worldwide Bluetooth Semiconductor 2008-2012 Forecast," published November 2008, a forthcoming radio frequency communication ("wireless connectivity") standard, Bluetooth low energy, will link wireless sensors via radio signals to the 70% of cell phones and computers likely to be fitted with the next generation of Bluetooth wireless technology, leveraging a ready-built infrastructure for data transmission. Analysis of trends indicated by this data can help physicians better manage diseases such as diabetes. The technology also addresses the concerns of cost, compatibility, and interoperability that have previously stalled widespread adoption of wireless technology in medical applications. (c) 2010 Diabetes Technology Society.

  2. Experimental validation of wireless communication with chaos

    Energy Technology Data Exchange (ETDEWEB)

    Ren, Hai-Peng; Bai, Chao; Liu, Jian [Shaanxi Key Laboratory of Complex System Control and Intelligent Information Processing, Xian University of Technology, Xian 710048 (China); Baptista, Murilo S.; Grebogi, Celso [Institute for Complex System and Mathematical Biology, SUPA, University of Aberdeen, Aberdeen AB24 3UE (United Kingdom)

    2016-08-15

    The constraints of a wireless physical media, such as multi-path propagation and complex ambient noises, prevent information from being communicated at low bit error rate. Surprisingly, it has only recently been shown that, from a theoretical perspective, chaotic signals are optimal for communication. It maximises the receiver signal-to-noise performance, consequently minimizing the bit error rate. This work demonstrates numerically and experimentally that chaotic systems can in fact be used to create a reliable and efficient wireless communication system. Toward this goal, we propose an impulsive control method to generate chaotic wave signals that encode arbitrary binary information signals and an integration logic together with the match filter capable of decreasing the noise effect over a wireless channel. The experimental validation is conducted by inputting the signals generated by an electronic transmitting circuit to an electronic circuit that emulates a wireless channel, where the signals travel along three different paths. The output signal is decoded by an electronic receiver, after passing through a match filter.

  3. Experimental validation of wireless communication with chaos

    Science.gov (United States)

    Ren, Hai-Peng; Bai, Chao; Liu, Jian; Baptista, Murilo S.; Grebogi, Celso

    2016-08-01

    The constraints of a wireless physical media, such as multi-path propagation and complex ambient noises, prevent information from being communicated at low bit error rate. Surprisingly, it has only recently been shown that, from a theoretical perspective, chaotic signals are optimal for communication. It maximises the receiver signal-to-noise performance, consequently minimizing the bit error rate. This work demonstrates numerically and experimentally that chaotic systems can in fact be used to create a reliable and efficient wireless communication system. Toward this goal, we propose an impulsive control method to generate chaotic wave signals that encode arbitrary binary information signals and an integration logic together with the match filter capable of decreasing the noise effect over a wireless channel. The experimental validation is conducted by inputting the signals generated by an electronic transmitting circuit to an electronic circuit that emulates a wireless channel, where the signals travel along three different paths. The output signal is decoded by an electronic receiver, after passing through a match filter.

  4. A telemetry system embedded in clothes for indoor localization and elderly health monitoring.

    Science.gov (United States)

    Charlon, Yoann; Fourty, Nicolas; Campo, Eric

    2013-09-04

    This paper presents a telemetry system used in a combined trilateration method for the precise indoor localization of the elderly who need health monitoring. The system is based on the association of two wireless technologies: ultrasonic and 802.15.4. The use of the 802.15.4 RF signal gives the reference starting time of the ultrasonic emission (time difference of arrival method). A time of flight measurement of the ultrasonic pulses provides the distances between the mobile node and three anchor points. These distance measurements are then used to locate the mobile node using the trilateration method with an accuracy of a few centimetres. The originality of our work lies in embedding the mobile node in clothes. The system is embedded in clothes in two ways: on a shoe in order to form a "smart" shoe and in a hat in order to form a "smart" hat. Both accessories allow movements, gait speed and distance covered to be monitored for health applications. Experiments in a test room are presented to show the effectiveness of our system.

  5. A Telemetry System Embedded in Clothes for Indoor Localization and Elderly Health Monitoring

    Directory of Open Access Journals (Sweden)

    Eric Campo

    2013-09-01

    Full Text Available This paper presents a telemetry system used in a combined trilateration method for the precise indoor localization of the elderly who need health monitoring. The system is based on the association of two wireless technologies: ultrasonic and 802.15.4. The use of the 802.15.4 RF signal gives the reference starting time of the ultrasonic emission (time difference of arrival method. A time of flight measurement of the ultrasonic pulses provides the distances between the mobile node and three anchor points. These distance measurements are then used to locate the mobile node using the trilateration method with an accuracy of a few centimetres. The originality of our work lies in embedding the mobile node in clothes. The system is embedded in clothes in two ways: on a shoe in order to form a “smart” shoe and in a hat in order to form a “smart” hat. Both accessories allow movements, gait speed and distance covered to be monitored for health applications. Experiments in a test room are presented to show the effectiveness of our system.

  6. Security for multihop wireless networks

    CERN Document Server

    Khan, Shafiullah

    2014-01-01

    Security for Multihop Wireless Networks provides broad coverage of the security issues facing multihop wireless networks. Presenting the work of a different group of expert contributors in each chapter, it explores security in mobile ad hoc networks, wireless sensor networks, wireless mesh networks, and personal area networks.Detailing technologies and processes that can help you secure your wireless networks, the book covers cryptographic coprocessors, encryption, authentication, key management, attacks and countermeasures, secure routing, secure medium access control, intrusion detection, ep

  7. Precise timing correlation in telemetry recording and processing systems

    Science.gov (United States)

    Pickett, R. B.; Matthews, F. L.

    1973-01-01

    Independent PCM telemetry data signals received from missiles must be correlated to within + or - 100 microseconds for comparison with radar data. Tests have been conducted to determine RF antenna receiving system delays; delays associated with wideband analog tape recorders used in the recording, dubbing and repdocuing processes; and uncertainties associated with computer processed time tag data. Several methods used in the recording of timing are evaluated. Through the application of a special time tagging technique, the cumulative timing bias from all sources is determined and the bias removed from final data. Conclusions show that relative time differences in receiving, recording, playback and processing of two telemetry links can be accomplished with a + or - 4 microseconds accuracy. In addition, the absolute time tag error (with respect to UTC) can be reduced to less than 15 microseconds. This investigation is believed to be the first attempt to identify the individual error contributions within the telemetry system and to describe the methods of error reduction within the telemetry system and to describe the methods of error reduction and correction.

  8. Telemetry with an Optical Fiber Revisited: An Alternative Strategy

    Science.gov (United States)

    Kraftmakher, Yaakov

    2014-01-01

    With a new data-acquisition system developed by PASCO scientific, an experiment on telemetry with an optical fiber can be made easier and more accurate. For this aim, an alternative strategy of the remote temperature measurements is proposed: the frequency of light pulses transmitted via the light guide numerically equals the temperature using…

  9. Submersible telemetry system downhole unit model for the petroleum industry

    Science.gov (United States)

    Rubtsova, O. O.; Trofimova, E. S.; Ishchenko, A. V.; Cherepanov, A. N.; Danilov, V. Yu.

    2017-09-01

    This article addresses the issue of increasing requirements for the oil industry: the need to develop new wells and control their profitability. The device under consideration (a submersible telemetry system that is capable of measuring well parameters and transferring them via the communication line to the ground based control system) will allow to avoid downtime when it is extracted for indicators check.

  10. Impact of cardiac telemetry on patient safety and cost.

    Science.gov (United States)

    Benjamin, Evan M; Klugman, Robert A; Luckmann, Roger; Fairchild, David G; Abookire, Susan A

    2013-06-01

    With the impetus for healthcare reform and the imperative for healthcare organizations to improve efficiency and reduce waste, it is valuable to examine high-volume procedures and practices in order to identify potential overuse. At the same time, organizations must ensure that improved efficiency does not inadvertently reduce patient safety. We undertook a multicenter analysis of the use of adult cardiac telemetry outside of the intensive care unit or step-down units at 4 teaching hospitals to determine the percentage of monitoring days that were not justified by an accepted indication and the monetary costs associated with these nonindicated days. We also assessed the safety of eliminating monitoring on days when it was not justified by looking at the incidence of arrhythmias. We found that in 35% of telemetry days, telemetry use was not supported by an accepted set of clinical indications. The incidence of arrhythmias on nonindicated days was low (3.1 per 100 days of monitoring per nonindicated day),and the arrhythmias detected were clinically insignificant. Eliminating monitoring on nonindicated days could save a minimum of $53 per patient per day. The average 400-bed hospital with a conservative estimate of 5000 nonindicated patientdays per year could save $250,000 per year. Reducing the use of telemetry on nonindicated days may provide an opportunity for institutions to safely reduce cost as well as staff time and effort, while maintaining and potentially increasing patient safety.

  11. Evaluation of a GPS used in conjunction with aerial telemetry

    Science.gov (United States)

    Olexa, E.M.; Gogan, P.J.P.; Podruzny, K.M.; Eiler, John; Alcorn, Doris J.; Neuman, Michael R.

    2001-01-01

    We investigated the use of a non-correctable Global Positioning System (NGPS) in association with aerial telemetry to determine animal locations. Average error was determined for 3 components of the location process: use of a NGPS receiver on the ground, use of a NGPS receiver in a aircraft while flying over a visual marker, and use of the same receiver while flying over a location determined by standard aerial telemetry. Average errors were 45.3, 88.1 and 137.4 m, respectively. A directional bias of Tests indicated that use of NGPS to determine aircraft, and thereby animal, location is an efficient alternative to interpolation from topographic maps. This method was more accurate than previously reported Long-Range Navigation system, version C (LORAN-C) and Argos satellite telemetry. It has utility in areas where animal-borne GPS receivers are not practical due to a combination of topography, canopy coverage, weight or cost of animal-borne GPS units. Use of NGPS technology in conjunction with aerial telemetry will provide the location accuracy required for identification of gross movement patterns and coarse-grained habitat use.

  12. Satellite telemetry of Afrotropical ducks: methodological details and ...

    African Journals Online (AJOL)

    Despite widespread and increasing use of solarpowered satellite transmitters to tag wild birds, there are few published articles that detail how transmitters should be attached to different species and even fewer assessments of the overall field success of telemetry projects. The scarcity of this information makes it difficult to ...

  13. Implementing telemetry on new species in remote areas ...

    African Journals Online (AJOL)

    We provide recommendations for implementing telemetry studies on waterfowl on the basis of our experience in a tracking study conducted in three countries of sub-Saharan Africa. The aim of the study was to document movements by duck species identified as priority candidates for the potential spread of avian influenza.

  14. The wireless internet explained

    CERN Document Server

    Rhoton, John

    2001-01-01

    The Wireless Internet Explained covers the full spectrum of wireless technologies from a wide range of vendors, including initiatives by Microsoft and Compaq. The Wireless Internet Explained takes a practical look at wireless technology. Rhoton explains the concepts behind the physics, and provides an overview that clarifies the convoluted set of standards heaped together under the umbrella of wireless. It then expands on these technical foundations to give a panorama of the increasingly crowded landscape of wireless product offerings. When it comes to actual implementation the book gives abundant down-to-earth advice on topics ranging from the selection and deployment of mobile devices to the extremely sensitive subject of security.Written by an expert on Internet messaging, the author of Digital Press''s successful Programmer''s Guide to Internet Mail and X.400 and SMTP: Battle of the E-mail Protocols, The Wireless Internet Explained describes and evaluates the current state of the fast-growing and crucial...

  15. Reception of Multiple Telemetry Signals via One Dish Antenna

    Science.gov (United States)

    Mukai, Ryan; Vilnrotter, Victor

    2010-01-01

    A microwave aeronautical-telemetry receiver system includes an antenna comprising a seven-element planar array of receiving feed horns centered at the focal point of a paraboloidal dish reflector that is nominally aimed at a single aircraft or at multiple aircraft flying in formation. Through digital processing of the signals received by the seven feed horns, the system implements a method of enhanced cancellation of interference, such that it becomes possible to receive telemetry signals in the same frequency channel simultaneously from either or both of two aircraft at slightly different angular positions within the field of view of the antenna, even in the presence of multipath propagation. The present system is an advanced version of the system described in Spatio- Temporal Equalizer for a Receiving-Antenna Feed Array NPO-43077, NASA Tech Briefs, Vol. 34, No. 2 (February 2010), page 32. To recapitulate: The radio-frequency telemetry signals received by the seven elements of the array are digitized, converted to complex baseband form, and sent to a spatio-temporal equalizer that consists mostly of a bank of seven adaptive finite-impulse-response (FIR) filters (one for each element in the array) plus a unit that sums the outputs of the filters. The combination of the spatial diversity of the feedhorn array and the temporal diversity of the filter bank affords better multipath suppression performance than is achievable by means of temporal equalization alone. The FIR filter bank adapts itself in real time to enable reception of telemetry at a low bit error rate, even in the presence of frequency-selective multipath propagation like that commonly found at flight-test ranges. The combination of the array and the filter bank makes it possible to constructively add multipath incoming signals to the corresponding directly arriving signals, thereby enabling reductions in telemetry bit-error rates.

  16. Wireless rechargeable sensor networks

    CERN Document Server

    Yang, Yuanyuan

    2015-01-01

    This SpringerBrief provides a concise guide to applying wireless energy transfer techniques in traditional battery-powered sensor networks. It examines the benefits and challenges of wireless power including efficiency and reliability. The authors build a wireless rechargeable sensor networks from scratch and aim to provide perpetual network operation. Chapters cover a wide range of topics from the collection of energy information and recharge scheduling to joint design with typical sensing applications such as data gathering. Problems are approached using a natural combination of probability

  17. Wireless network pricing

    CERN Document Server

    Huang, Jianwei

    2013-01-01

    Today's wireless communications and networking practices are tightly coupled with economic considerations, to the extent that it is almost impossible to make a sound technology choice without understanding the corresponding economic implications. This book aims at providing a foundational introduction on how microeconomics, and pricing theory in particular, can help us to understand and build better wireless networks. The book can be used as lecture notes for a course in the field of network economics, or a reference book for wireless engineers and applied economists to understand how pricing

  18. Wireless mesh networks

    CERN Document Server

    Held, Gilbert

    2005-01-01

    Wireless mesh networking is a new technology that has the potential to revolutionize how we access the Internet and communicate with co-workers and friends. Wireless Mesh Networks examines the concept and explores its advantages over existing technologies. This book explores existing and future applications, and examines how some of the networking protocols operate.The text offers a detailed analysis of the significant problems affecting wireless mesh networking, including network scale issues, security, and radio frequency interference, and suggests actual and potential solutions for each pro

  19. Optical and wireless technologies

    CERN Document Server

    Tiwari, Manish; Singh, Ghanshyam; Minzioni, Paolo

    2018-01-01

    This book presents selected papers from 1st International Conference on Optical and Wireless Technologies, providing insights into the analytical, experimental, and developmental aspects of systems, techniques, and devices in these spheres. It explores the combined use of various optical and wireless technologies in next-generation networking applications, and discusses the latest developments in applications such as photonics, high-speed communication systems and networks, visible light communication, nanophotonics, and wireless and multiple-input-multiple-output (MIMO) systems. The book will serve as a valuable reference resource for academics and researchers across the globe.

  20. A multi-port power electronics interface for battery powered electric vehicles: Application of inductively coupled wireless power transfer and hybrid energy storage system

    Science.gov (United States)

    McDonough, Matthew Kelly

    Climate change, pollution, and geopolitical conflicts arising from the extreme wealth concentrations caused by fossil fuel deposits are just a few of the side-effects of the way that we fuel our society. A new method to power our civilization is becoming more and more necessary. Research for new, more sustainable fuel sources is already underway due to research in wind, solar, geothermal, and hydro power. However this focus is mainly on stationary applications. A large portion of fossil fuel usage comes from transportation. Unfortunately, the transition to cleaner transportation fuels is being stunted by the inability to store adequate amounts of energy in electro-chemical batteries. The idea of charging while driving has been proposed by many researchers, however several challenges still exist. In this work some of these challenges are addressed. Specifically, the ability to route power from multiple sources/loads is investigated. Special attention is paid to adjusting the time constant of particular converters, namely the battery and ultra-capacitor converters to reduce the high frequency and high magnitude current components applied to the battery terminals. This is done by developing a closed loop model of the entire multi-port converter, including the state of charge of the ultra-capacitors. The development of closed loop models and two experimental testbeds for use as stationary vehicle charging platforms with their unique set of sources/loads are presented along-side an on-board charger to demonstrate the similarities and differences between stationary charging and mobile charging. Experimental results from each are given showing that it is not only possible, but feasible to utilize Inductively Coupled Wireless Power Transfer (ICWPT) to charge a battery powered electric vehicle while driving and still protect the life-span of the batteries under the new, harsher conditions generated by the ICWPT system.

  1. Feasibility Study on Active Back Telemetry and Power Transmission Through an Inductive Link for Millimeter-Sized Biomedical Implants.

    Science.gov (United States)

    Yeon, Pyungwoo; Mirbozorgi, S Abdollah; Lim, Jaemyung; Ghovanloo, Maysam

    2017-12-01

    This paper presents a feasibility study of wireless power and data transmission through an inductive link to a 1-mm 2 implant, to be used as a free-floating neural probe, distributed across a brain area of interest. The proposed structure utilizes a four-coil inductive link for back telemetry, shared with a three-coil link for wireless power transmission. We propose a design procedure for geometrical optimization of the inductive link in terms of power transmission efficiency (PTE) considering specific absorption rate and data rate. We have designed a low-power pulse-based active data transmission circuit and characterized performance of the proposed inductive link in terms of its data rate and bit error rate (BER). The 1-mm 2 data-Tx/power-Rx coil is implemented using insulated bonding wire with diameter, resulting in measured PTE in tissue media of 2.01% at 131 MHz and 1.8-cm coil separation distance when the resonator coil inner radius is 1 cm. The measured BER at 1-Mbps data rate was and in the air and tissue environments, respectively.

  2. Wireless capsule endoscopy

    Science.gov (United States)

    Iddan, Gavriel; Meron, Gavriel; Glukhovsky, Arkady; Swain, Paul

    2000-05-01

    We have developed a new type of endoscopy, which for the first time allows painless endoscopic imaging of the whole of the small bowel. This procedure involves a wireless capsule endoscope and we describe here its successful testing in humans.

  3. Green heterogeneous wireless networks

    CERN Document Server

    Ismail, Muhammad; Nee, Hans-Peter; Qaraqe, Khalid A; Serpedin, Erchin

    2016-01-01

    This book focuses on the emerging research topic "green (energy efficient) wireless networks" which has drawn huge attention recently from both academia and industry. This topic is highly motivated due to important environmental, financial, and quality-of-experience (QoE) considerations. Specifically, the high energy consumption of the wireless networks manifests in approximately 2% of all CO2 emissions worldwide. This book presents the authors’ visions and solutions for deployment of energy efficient (green) heterogeneous wireless communication networks. The book consists of three major parts. The first part provides an introduction to the "green networks" concept, the second part targets the green multi-homing resource allocation problem, and the third chapter presents a novel deployment of device-to-device (D2D) communications and its successful integration in Heterogeneous Networks (HetNets). The book is novel in that it specifically targets green networking in a heterogeneous wireless medium, which re...

  4. Wireless radio a history

    CERN Document Server

    Coe, Lewis

    2006-01-01

    ""Informative...recommended""--Choice; ""interesting...a good read...well worth reading""--Contact Magazine. This history first looks at Marconi's wireless communications system and then explores its many applications, including marine radio, cellular telephones, police and military uses, television and radar. Radio collecting is also discussed, and brief biographies are provided for the major figures in the development and use of the wireless.

  5. Wireless Networks Security

    OpenAIRE

    Jenko, Marko

    2016-01-01

    In this thesis we deal with security, penetration testing and different types of attacks on wireless networks. We theoretically familiarize with the field of wireless networks, security mechanisms and the most used security standards. Then we systematically overview the field of penetration testing. We divide the penetration testing on types and different methodologies. We explain the tasks of the provider and the subscriber in penetration testing. Description of the process of conducting the...

  6. Energy-aware Wireless Multi-hop Networks

    OpenAIRE

    Vazifehdan, J.

    2011-01-01

    Wireless networks have provided us a variety of services which facilitate communication between people beyond the physical boundaries. Mobile telephony, mobile Internet and high-deffnition video calls are examples of services supported by modern networks nowadays. Beyond this, enhancements in processing capabilities of electronic devices coupled with advances in wireless communication have resulted in the emergence of devices which have high processing and communication capabilities. Small de...

  7. Adoption of wireless internet parks: An empirical study in Qatar

    OpenAIRE

    Weerakkody, V

    2008-01-01

    This paper examines the adoption of free wireless internet parks (iPark) by Qatari citizens as means of accessing electronic services from public parks. The Qatar government has launched the iPark concept with a view of providing free internet access for all citizens while enjoying the outdoors. By offering free wireless Internet access, the Qatari government encourages its citizen's to actively participate in the global information society with a view of bridging the digital divide. Using a ...

  8. Wireless Sensor Networks for Long Distance Pipeline Monitoring

    OpenAIRE

    Augustine C. Azubogu; Victor E. Idigo; Schola U. Nnebe; Obinna S. Oguejiofor; Simon E.

    2013-01-01

    The main goal of this seminal paper is to introduce the application of Wireless Sensor Networks (WSN) in long distance infrastructure monitoring (in particular in pipeline infrastructure monitoring) – one of the on-going research projects by the Wireless Communication Research Group at the department of Electronic and Computer Engineering, Nnamdi Azikiwe University, Awka. The current sensor network architectures for monitoring long distance pipeline infrastructures are pr...

  9. Wireless Networks: New Meaning to Ubiquitous Computing.

    Science.gov (United States)

    Drew, Wilfred, Jr.

    2003-01-01

    Discusses the use of wireless technology in academic libraries. Topics include wireless networks; standards (IEEE 802.11); wired versus wireless; why libraries implement wireless technology; wireless local area networks (WLANs); WLAN security; examples of wireless use at Indiana State University and Morrisville College (New York); and useful…

  10. Ultra Secure High Reliability Wireless Radiation Monitor

    International Nuclear Information System (INIS)

    Cordaro, J.; Shull, D.; Farrar, M.; Reeves, G.

    2011-01-01

    Radiation monitoring in nuclear facilities is essential to safe operation of the equipment as well as protecting personnel. In specific, typical air monitoring of radioactive gases or particulate involves complex systems of valves, pumps, piping and electronics. The challenge is to measure a representative sample in areas that are radioactively contaminated. Running cables and piping to these locations is very expensive due to the containment requirements. Penetration into and out of an airborne or containment area is complex and costly. The process rooms are built with thick rebar-enforced concrete walls with glove box containment chambers inside. Figure 1 shows high temperature radiation resistance cabling entering the top of a typical glove box. In some case, the entire processing area must be contained in a 'hot cell' where the only access into the chamber is via manipulators. An example is shown in Figure 2. A short range wireless network provides an ideal communication link for transmitting the data from the radiation sensor to a 'clean area', or area absent of any radiation fields or radioactive contamination. Radiation monitoring systems that protect personnel and equipment must meet stringent codes and standards due to the consequences of failure. At first glance a wired system would seem more desirable. Concerns with wireless communication include latency, jamming, spoofing, man in the middle attacks, and hacking. The Department of Energy's Savannah River National Laboratory (SRNL) has developed a prototype wireless radiation air monitoring system that address many of the concerns with wireless and allows quick deployment in radiation and contamination areas. It is stand alone and only requires a standard 120 VAC, 60 Hz power source. It is designed to be mounted or portable. The wireless link uses a National Security Agency (NSA) Suite B compliant wireless network from Fortress Technologies that is considered robust enough to be used for classified data

  11. ULTRA SECURE HIGH RELIABILITY WIRELESS RADIATION MONITOR

    Energy Technology Data Exchange (ETDEWEB)

    Cordaro, J.; Shull, D.; Farrar, M.; Reeves, G.

    2011-08-03

    Radiation monitoring in nuclear facilities is essential to safe operation of the equipment as well as protecting personnel. In specific, typical air monitoring of radioactive gases or particulate involves complex systems of valves, pumps, piping and electronics. The challenge is to measure a representative sample in areas that are radioactively contaminated. Running cables and piping to these locations is very expensive due to the containment requirements. Penetration into and out of an airborne or containment area is complex and costly. The process rooms are built with thick rebar-enforced concrete walls with glove box containment chambers inside. Figure 1 shows high temperature radiation resistance cabling entering the top of a typical glove box. In some case, the entire processing area must be contained in a 'hot cell' where the only access into the chamber is via manipulators. An example is shown in Figure 2. A short range wireless network provides an ideal communication link for transmitting the data from the radiation sensor to a 'clean area', or area absent of any radiation fields or radioactive contamination. Radiation monitoring systems that protect personnel and equipment must meet stringent codes and standards due to the consequences of failure. At first glance a wired system would seem more desirable. Concerns with wireless communication include latency, jamming, spoofing, man in the middle attacks, and hacking. The Department of Energy's Savannah River National Laboratory (SRNL) has developed a prototype wireless radiation air monitoring system that address many of the concerns with wireless and allows quick deployment in radiation and contamination areas. It is stand alone and only requires a standard 120 VAC, 60 Hz power source. It is designed to be mounted or portable. The wireless link uses a National Security Agency (NSA) Suite B compliant wireless network from Fortress Technologies that is considered robust enough to be

  12. Wireless Luminescence Integrated Sensors (WLIS)

    Energy Technology Data Exchange (ETDEWEB)

    Simpson, M.L.; Sayler, G.S. (Univ. Tennessee)

    2003-11-10

    The goal of this project was the development of a family of wireless, single-chip, luminescence-sensing devices to solve a number of difficult distributed measurement problems in areas ranging from environmental monitoring and assessment to high-throughput screening of combinatorial chemistry libraries. These wireless luminescence integrated sensors (WLIS) consist of a microluminometer, wireless data transmitter, and RF power input circuit all realized in a standard integrated circuit (IC) process with genetically engineered, whole-cell, bioluminescent bioreporters encapsulated and deposited on the IC. The end product is a family of compact, low-power, rugged, low-cost sensors. As part of this program they developed an integrated photodiode/signal-processing scheme with an rms noise level of 175 electrons/second for a 13-minute integration time, and a quantum efficiency of 66% at the 490-nm bioluminescent wavelength. this performance provided a detection limit of < 1000 photons/second. Although sol-gel has previously been used to encapsulate yeast cells, the reaction conditions necessary for polymerization (primarily low pH) have beforehand proven too harsh for bacterial cell immobilizations. Utilizing sonication methods, they have were able to initiate polymerization under pH conditions conductive to cell survival. both a toluene bioreporter (Pseudomonas putida TVA8) and a naphthalene bioreporter (Pseudomonas fluorescens HK44) were successfully encapsulated in sol-gel and shown to produce a fairly significant bioluminescent response. In addition to the previously developed naphthalene- and toluene-sensitive bioreporters, they developed a yeast-based xenoestrogen reporter. This technology has been licensed by Micro Systems Technologies, a startup company in Dayton, Ohio for applications in environmental containments monitoring, and for detecting weapons of mass destruction (i.e. homeland security).

  13. CCSDS telemetry systems experience at the Goddard Space Flight Center

    Science.gov (United States)

    Carper, Richard D.; Stallings, William H., III

    1990-01-01

    NASA Goddard Space Flight Center (GSFC) designs, builds, manages, and operates science and applications spacecraft in near-earth orbit, and provides data capture, data processing, and flight control services for these spacecraft. In addition, GSFC has the responsibility of providing space-ground and ground-ground communications for near-earth orbiting spacecraft, including those of the manned spaceflight programs. The goal of reducing both the developmental and operating costs of the end-to-end information system has led the GSFC to support and participate in the standardization activities of the Consultative Committee for Space Data Systems (CCSDS), including those for packet telemetry. The environment in which such systems function is described, and the GSFC experience with CCSDS packet telemetry in the context of the Gamma-Ray Observatory project is discussed.

  14. Refinement of Telemetry for Measuring Blood Pressure in Conscious Rats

    Science.gov (United States)

    Braga, Valdir A; Prabhakar, Nanduri R

    2009-01-01

    Although considered the ‘gold standard’ for measuring blood pressure in laboratory animals, telemetry would benefit from refinement. In the present study, we tested the hypothesis that the small telemetric device used for blood pressure recording in mice would work for rats as well and would serve as an alternative for those studies where abdominal cavity space is quite limited (such as in young animals and pregnant females). Here we report that the use of a smaller and lighter telemetric device implanted in the abdominal aorta of rats led to acquisition of stable and high-quality blood pressure and heart rate data, similar to those obtained by using a larger telemetric device developed for rats. The use of smaller transmitters represents an alternative telemetry technique, especially for those cases in which space in the abdominal cavity is particularly limited such as during pregnancy. PMID:19476715

  15. A spatial mark–resight model augmented with telemetry data

    Science.gov (United States)

    Sollmann, Rachel; Gardner, Beth; Parsons, Arielle W.; Stocking, Jessica J.; McClintock, Brett T.; Simons, Theodore R.; Pollock, Kenneth H.; O’Connell, Allan F.

    2013-01-01

    Abundance and population density are fundamental pieces of information for population ecology and species conservation, but they are difficult to estimate for rare and elusive species. Mark-resight models are popular for estimating population abundance because they are less invasive and expensive than traditional mark-recapture. However, density estimation using mark-resight is difficult because the area sampled must be explicitly defined, historically using ad-hoc approaches. We develop a spatial mark-resight model for estimating population density that combines spatial resighting data and telemetry data. Incorporating telemetry data allows us to inform model parameters related to movement and individual location. Our model also allows 2. The model presented here will have widespread utility in future applications, especially for species that are not naturally marked.

  16. Vehicle safety telemetry for automated highways

    Science.gov (United States)

    Hansen, G. R.

    1977-01-01

    The emphasis in current, automatic vehicle testing and diagnosis is primarily centered on the proper operation of the engine. Lateral and longitudinal guidance technologies, including speed control and headway sensing for collision avoidance, are reviewed. The principal guidance technique remains the buried wire. Speed control and headway sensing, even though they show the same basic elements in braking and fuel systems, are proceeding independently. The applications of on-board electronic and microprocessor techniques were investigated; each application (emission control, spark advance, or anti-slip braking) is being treated as an independent problem is proposed. A unified bus system of distributed processors for accomplishing the various functions and testing required for vehicles equipped to use automated highways.

  17. Radio/Antenna Mounting System for Wireless Networking under Row-Crop Agriculture Conditions

    OpenAIRE

    Daniel K. Fisher

    2015-01-01

    Interest in and deployment of wireless monitoring systems is increasing in many diverse environments, including row-crop agricultural fields. While many studies have been undertaken to evaluate various aspects of wireless monitoring and networking, such as electronic hardware components, data-collection procedures, power management, and communication protocols, little information related to physical deployment issues has been reported. To achieve acceptable wireless transmission capability, t...

  18. Extreme-Environment Silicon-Carbide (SiC) Wireless Sensor Suite

    Science.gov (United States)

    Yang, Jie

    2015-01-01

    Phase II objectives: Develop an integrated silicon-carbide wireless sensor suite capable of in situ measurements of critical characteristics of NTP engine; Compose silicon-carbide wireless sensor suite of: Extreme-environment sensors center, Dedicated high-temperature (450 deg C) silicon-carbide electronics that provide power and signal conditioning capabilities as well as radio frequency modulation and wireless data transmission capabilities center, An onboard energy harvesting system as a power source.

  19. Telemetry Timing Analysis for Image Reconstruction of Kompsat Spacecraft

    Directory of Open Access Journals (Sweden)

    Jin-Ho Lee

    2000-06-01

    Full Text Available The KOMPSAT (KOrea Multi-Purpose SATellite has two optical imaging instruments called EOC (Electro-Optical Camera and OSMI (Ocean Scanning Multispectral Imager. The image data of these instruments are transmitted to ground station and restored correctly after post-processing with the telemetry data transferred from KOMPSAT spacecraft. The major timing information of the KOMPSAT is OBT (On-Board Time which is formatted by the on-board computer of the spacecraft, based on 1Hz sync. pulse coming from the GPS receiver involved. The OBT is transmitted to ground station with the house-keeping telemetry data of the spacecraft while it is distributed to the instruments via 1553B data bus for synchronization during imaging and formatting. The timing information contained in the spacecraft telemetry data would have direct relation to the image data of the instruments, which should be well explained to get a more accurate image. This paper addresses the timing analysis of the KOMPSAT spacecraft and instruments, including the gyro data timing analysis for the correct restoration of the EOC and OSMI image data at ground station.

  20. Upscaling behavioural studies to the field using acoustic telemetry.

    Science.gov (United States)

    Hellström, Gustav; Klaminder, Jonatan; Jonsson, Micael; Fick, Jerker; Brodin, Tomas

    2016-01-01

    Laboratory-based behavioural assays are often used in ecotoxicological studies to assess the environmental risk of aquatic contaminants. While results from such laboratory-based risk assessments may be difficult to extrapolate to natural environments, technological advancements over the past decade now make it possible to perform risk assessments through detailed studies of exposed individuals in natural settings. Acoustic telemetry is a technology to monitor movement and behaviour of aquatic organism in oceans, lakes, and rivers. The technology allows for tracking of multiple individuals simultaneously with very high temporal and spatial resolution, with the option to incorporate sensors to measure various physiological and environmental parameters. Although frequently used in fisheries research, aquatic ecotoxicology has been slow to adopt acoustic telemetry as a tool in field-based studies. This mini-review intends to introduce acoustic telemetry to aquatic ecotoxicologists, focusing on the potential of the technology to bridge the gap between laboratory assays and natural behaviours when making toxicological risk assessments. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Improving estimation of flight altitude in wildlife telemetry studies

    Science.gov (United States)

    Poessel, Sharon; Duerr, Adam E.; Hall, Jonathan C.; Braham, Melissa A.; Katzner, Todd

    2018-01-01

    Altitude measurements from wildlife tracking devices, combined with elevation data, are commonly used to estimate the flight altitude of volant animals. However, these data often include measurement error. Understanding this error may improve estimation of flight altitude and benefit applied ecology.There are a number of different approaches that have been used to address this measurement error. These include filtering based on GPS data, filtering based on behaviour of the study species, and use of state-space models to correct measurement error. The effectiveness of these approaches is highly variable.Recent studies have based inference of flight altitude on misunderstandings about avian natural history and technical or analytical tools. In this Commentary, we discuss these misunderstandings and suggest alternative strategies both to resolve some of these issues and to improve estimation of flight altitude. These strategies also can be applied to other measures derived from telemetry data.Synthesis and applications. Our Commentary is intended to clarify and improve upon some of the assumptions made when estimating flight altitude and, more broadly, when using GPS telemetry data. We also suggest best practices for identifying flight behaviour, addressing GPS error, and using flight altitudes to estimate collision risk with anthropogenic structures. Addressing the issues we describe would help improve estimates of flight altitude and advance understanding of the treatment of error in wildlife telemetry studies.

  2. Effectiveness of Telemetry Guidelines in Predicting Clinically Significant Arrhythmias in Hospitalized Patients

    Science.gov (United States)

    Dhillon, Sandeep K.; JosephTawil; Goldstein, Baruch; Eslava-Manchego, Dayana; Singh, Jagdeep; Hanon, Sam; Schweitzer, Paul; Bergmann, Steven R.

    2012-01-01

    Background Cardiac rhythm monitoring is widely applied on hospitalized patients. However, its value has not been evaluated systematically. Methods This study considered the utility of our institutional telemetry guidelines in predicting clinically significant arrhythmias. A retrospective analysis was performed of 562 patients admitted to the telemetry unit. A total of 1932 monitoring days were evaluated. Patients were divided into 2 groups based on telemetry guidelines: “telemetry indicated” and “telemetry not indicated”. Results Differences in arrhythmia event rates and pre-defined clinical significance were determined. One hundred and forty-four (34%) vs. 16 (11%) patients had at least one arrhythmic event in the “telemetry indicated” group compared with the “telemetry not indicated” group, respectively (P = 0.001). No patient in the “telemetry not indicated” group had a clinically significant arrhythmia. In contrast, of patients in the “telemetry indicated” group who had at least one arrhythmic event, 36% were considered clinically significant (P telemetry guidelines to allocate this resource appropriately and predict clinically significant arrhythmias. PMID:28357019

  3. EPMT: a portable transfer standard for telemetry system pressure-transducer calibration

    International Nuclear Information System (INIS)

    Hasbrouck, R.T.

    1977-01-01

    The LLL developed electronic pressure meter (EPMT) is a portable static-pressure calibration instrument for use with the LLL telemetry transducer system at the Nevada Test Site (NTS). It is significantly more accurate and rugged than the bourdon-tube pressure gauge it replaces, and can be incorporated into a field-use, semi-automatic, pressure calibration system. The process by which a transducer is selected for EPMT use from the inventory of field-service-certified transducers and subjected to an extensive preconditioning and calibration procedure is described. By combining this unusual calibration procedure with a unique, statistically based data-reduction routine, the total uncertainty of the measuring process at each calibration point can be determined with high accuracy

  4. OPTICAL WIRELESS COMMUNICATION SYSTEM

    Directory of Open Access Journals (Sweden)

    JOSHUA L.Y. CHIENG

    2016-02-01

    Full Text Available The growing demand of bandwidth in this modern internet age has been testing the existing telecommunication infrastructures around the world. With broadband speeds moving towards the region of Gbps and Tbps, many researches have begun on the development of using optical wireless technology as feasible and future methods to the current wireless technology. Unlike the existing radio frequency wireless applications, optical wireless uses electromagnetic spectrums that are unlicensed and free. With that, this project aim to understand and gain better understanding of optical wireless communication system by building an experimental and simulated model. The quality of service and system performance will be investigated and reviewed. This project employs laser diode as the propagation medium and successfully transferred audio signals as far as 15 meters. On its quality of service, results of the project model reveal that the bit error rate increases, signal-to-noise ratio and quality factor decreases as the link distance between the transmitter and receiver increases. OptiSystem was used to build the simulated model and MATLAB was used to assist signal-to-noise ratio calculations. By comparing the simulated and experimental receiver’s power output, the experimental model’s efficiency is at 66.3%. Other than the system’s performance, challenges and factors affecting the system have been investigated and discussed. Such challenges include beam divergence, misalignment and particle absorption.

  5. Test Methods for Telemetry Systems and Subsystems. Volume 2: Test Methods for Telemetry Radio Frequency (RF) Subsystems

    Science.gov (United States)

    2012-09-01

    xvi PCM pulse code modulation PM phase modulation p/s pulse per second RCC Range Commanders Council RCP right circular polarization RF...to be tested at a variety of environmental conditions such as temperature, humidity, vibration , and shock. The user needs to determine the...Figure 1-6. Ensure the bore sight source antenna is facing the telemetry (TM)-tracking antenna directly RCP Rx Tracking Error Demod. Voltmeter

  6. EXPERIMENTAL PERFORMANCE ANALYSIS OF WIRELESS ...

    African Journals Online (AJOL)

    ABSTRACT. Wireless networking is currently being deployed for various applications. However, the application of wireless networking in healthcare remains a challenge mainly because of security and reliability concerns. This paper presents experimental results of performance analysis of a wireless network for healthcare ...

  7. Terahertz (THz) Wireless Systems for Space Applications

    Science.gov (United States)

    Hwu, Shian U.; deSilva, Kanishka B.; Jih, Cindy T.

    2013-01-01

    NASA has been leading the Terahertz (THz) technology development for the sensors and instruments in astronomy in the past 20 years. THz technologies are expanding into much broader applications in recent years. Due to the vast available multiple gigahertz (GHz) broad bandwidths, THz radios offer the possibility for wireless transmission of high data rates. Multi-Gigabits per second (MGbps) broadband wireless access based on THz waves are closer to reality. The THz signal high atmosphere attenuation could significantly decrease the communication ranges and transmittable data rates for the ground systems. Contrary to the THz applications on the ground, the space applications in the atmosphere free environment do not suffer the atmosphere attenuation. The manufacturing technologies for the THz electronic components are advancing and maturing. There is great potential for the NASA future high data wireless applications in environments with difficult cabling and size/weight constraints. In this study, the THz wireless systems for potential space applications were investigated. The applicability of THz systems for space applications was analyzed. The link analysis indicates that MGbps data rates are achievable with compact sized high gain antennas.

  8. Wireless pH capsule--yield in clinical practice.

    Science.gov (United States)

    Roman, S; Mion, F; Zerbib, F; Benamouzig, R; Letard, J C; Bruley des Varannes, S

    2012-03-01

    Wireless pH monitoring is one of the recent technologies that focus on improving the diagnosis of gastroesophageal reflux disease (GERD). The capsule, which is fixed within the esophagus, transmits data via telemetry to an external receiver. The capsule is usually inserted 6 cm above the squamocolumnar junction during an upper endoscopy. The standard recording duration is 48 hours but this can be extended to 96 hours. The wireless capsule has been shown to be at least as accurate as the conventional catheter for the monitoring of esophageal pH. Normal pH values have been established in three different series. The use of a wireless capsule provides an increased diagnostic yield for GERD compared with the conventional catheter. The increased yield is the result of higher sensitivity to detect both abnormal acid esophageal exposure and positive symptom-reflux association. This may be related both to the prolonged recording duration and to fewer dietary modifications and restrictions on activities. Several studies have shown that the pH capsule was better tolerated by patients than the conventional pH catheter. Mild-to-moderate chest pain represents the main side effect of the pH capsule: severe chest pain requiring endoscopic removal of the capsule is rare. The main indication for wireless capsule application is monitoring of distal esophageal pH for diagnostic purpose, particularly in patients with a normal endoscopic examination. The capsule technique has some limitations: costs are higher than conventional pH monitoring, misplacement may occur, and the sampling rate is lower. Finally, compared with pH-impedance monitoring, only acid reflux events can be evaluated. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Fiber wireless networks

    Science.gov (United States)

    Nirmalathas, A.; Bakaul, M.; Lim, C.; Novak, D.; Waterhouse, R.

    2005-11-01

    Broadband wireless networks based on a number of new frequency windows at higher microwave and millimeter-wave frequencies have been actively pursued to provide ultra-high bandwidth services over a wireless networks. These networks will have a large number of antenna base-stations with high throughput. Significant reductions in antenna base-station complexity can be achieved if most of the signal routing and switching functions centralized at a central office in the network. In such a network, fiber feed networks can be effectively deployed to provide high bandwidth interconnections between multiple antenna base-stations and the central office. With wavelength division multiplexing, efficient optical fiber feed network architectures could be realised to provide interconnection to a large number of antenna base-stations. In this paper, we present an over view of our recent research into system technologies for fiber wireless networks.

  10. Wireless physical layer security

    Science.gov (United States)

    Poor, H. Vincent; Schaefer, Rafael F.

    2017-01-01

    Security in wireless networks has traditionally been considered to be an issue to be addressed separately from the physical radio transmission aspects of wireless systems. However, with the emergence of new networking architectures that are not amenable to traditional methods of secure communication such as data encryption, there has been an increase in interest in the potential of the physical properties of the radio channel itself to provide communications security. Information theory provides a natural framework for the study of this issue, and there has been considerable recent research devoted to using this framework to develop a greater understanding of the fundamental ability of the so-called physical layer to provide security in wireless networks. Moreover, this approach is also suggestive in many cases of coding techniques that can approach fundamental limits in practice and of techniques for other security tasks such as authentication. This paper provides an overview of these developments.

  11. Multichannel wireless ECoG array ASIC devices.

    Science.gov (United States)

    DeMichele, Glenn A; Cogan, Stuart F; Troyk, Philip R; Chen, Hongnan; Hu, Zhe

    2014-01-01

    Surgical resection of epileptogenic foci is often a beneficial treatment for patients suffering debilitating seizures arising from intractable epilepsy [1], [2], [3]. Electrodes placed subdurally on the surface of the brain in the form of an ECoG array is one of the multiple methods for localizing epileptogenic zones for the purpose of defining the region for surgical resection. Currently, transcutaneous wires from ECoG grids limit the duration of time that implanted grids can be used for diagnosis. A wireless ECoG recording and stimulation system may be a solution to extend the diagnostic period. To avoid the transcutaneous connections, a 64-channel wireless silicon recording/stimulating ASIC was developed as the electronic component of a wireless ECoG array that uses SIROF electrodes on a polyimide substrate[4]. Here we describe two new ASIC devices that have been developed and tested as part of the on-going wireless ECoG system design.

  12. Extending Wireless Broadband Network Architectures with Home Gateways, Localization, and Physical Environment Surveillance

    DEFF Research Database (Denmark)

    Jelling Kristoffersen, Kåre; Kjærgaard, Mikkel Baun; Chen, Jianjun

    2005-01-01

    Adding content is seen as the next important step in the development and deployment of broadband networks. This paper proposes three different ways of adding content to wireless broadband networks. First, the home gateway is presented as the focal point for delivery of digital services to future...... homes. It must bridge across the most prevalent standard protocols for data, video, telephony and telemetry, and must be able to automatically discover new devices in a residence and allow over the air/wire provisioning, billing, management and aggregation of new services from multiple service providers...

  13. Terabit Wireless Communication Challenges

    Science.gov (United States)

    Hwu, Shian U.

    2012-01-01

    This presentation briefly discusses a research effort on Terabit Wireless communication systems for possible space applications. Recently, terahertz (THz) technology (300-3000 GHz frequency) has attracted a great deal of interest from academia and industry. This is due to a number of interesting features of THz waves, including the nearly unlimited bandwidths available, and the non-ionizing radiation nature which does not damage human tissues and DNA with minimum health threat. Also, as millimeter-wave communication systems mature, the focus of research is, naturally, moving to the THz range. Many scientists regard THz as the last great frontier of the electromagnetic spectrum, but finding new applications outside the traditional niches of radio astronomy, Earth and planetary remote sensing, and molecular spectroscopy particularly in biomedical imaging and wireless communications has been relatively slow. Radiologists find this area of study so attractive because t-rays are non-ionizing, which suggests no harm is done to tissue or DNA. They also offer the possibility of performing spectroscopic measurements over a very wide frequency range, and can even capture signatures from liquids and solids. According to Shannon theory, the broad bandwidth of the THz frequency bands can be used for terabit-per-second (Tb/s) wireless communication systems. This enables several new applications, such as cell phones with 360 degrees autostereoscopic displays, optic-fiber replacement, and wireless Tb/s file transferring. Although THz technology could satisfy the demand for an extremely high data rate, a number of technical challenges need to be overcome before its development. This presentation provides an overview the state-of-the- art in THz wireless communication and the technical challenges for an emerging application in Terabit wireless systems. The main issue for THz wave propagation is the high atmospheric attenuation, which is dominated by water vapor absorption in the THz

  14. Wireless communications algorithmic techniques

    CERN Document Server

    Vitetta, Giorgio; Colavolpe, Giulio; Pancaldi, Fabrizio; Martin, Philippa A

    2013-01-01

    This book introduces the theoretical elements at the basis of various classes of algorithms commonly employed in the physical layer (and, in part, in MAC layer) of wireless communications systems. It focuses on single user systems, so ignoring multiple access techniques. Moreover, emphasis is put on single-input single-output (SISO) systems, although some relevant topics about multiple-input multiple-output (MIMO) systems are also illustrated.Comprehensive wireless specific guide to algorithmic techniquesProvides a detailed analysis of channel equalization and channel coding for wi

  15. Pervasive wireless environments

    CERN Document Server

    Yang, Jie; Trappe, Wade; Cheng, Jerry

    2014-01-01

    This Springer Brief provides a new approach to prevent user spoofing by using the physical properties associated with wireless transmissions to detect the presence of user spoofing. The most common method, applying cryptographic authentication, requires additional management and computational power that cannot be deployed consistently. The authors present the new approach by offering a summary of the recent research and exploring the benefits and potential challenges of this method. This brief discusses the feasibility of launching user spoofing attacks and their impact on the wireless and sen

  16. Wireless optical telecommunications

    CERN Document Server

    Bouchet, Olivier

    2013-01-01

    Wireless optical communication refers to communication based on the unguided propagation of optical waves. The past 30 years have seen significant improvements in this technique - a wireless communication solution for the current millennium - that offers an alternative to radio systems; a technique that could gain attractiveness due to recent concerns regarding the potential effects of radiofrequency waves on human health.The aim of this book is to look at the free space optics that are already used for the exchange of current information; its many benefits, such as incorporating chan

  17. Wireless telecommunication systems

    CERN Document Server

    Terré, Michel; Vivier, Emmanuelle

    2013-01-01

    Wireless telecommunication systems generate a huge amount of interest. In the last two decades, these systems have experienced at least three major technological leaps, and it has become impossible to imagine how society was organized without them. In this book, we propose a macroscopic approach on wireless systems, and aim at answering key questions about power, data rates, multiple access, cellular engineering and access networks architectures.We present a series of solved problems, whose objective is to establish the main elements of a global link budget in several radiocommunicati

  18. Data converters for wireless standards

    CERN Document Server

    Shi, Chunlei

    2002-01-01

    Wireless communication is witnessing tremendous growth with proliferation of different standards covering wide, local and personal area networks (WAN, LAN and PAN). The trends call for designs that allow 1) smooth migration to future generations of wireless standards with higher data rates for multimedia applications, 2) convergence of wireless services allowing access to different standards from the same wireless device, 3) inter-continental roaming. This requires designs that work across multiple wireless standards, can easily be reused, achieve maximum hardware share at a minimum power consumption levels particularly for mobile battery-operated devices.

  19. 75 FR 8400 - In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld...

    Science.gov (United States)

    2010-02-24

    ... Communications System Server Software, Wireless Handheld Devices and Battery Packs; Notice of Investigation... within the United States after importation of certain wireless communications system server software... certain wireless communications system server software, wireless handheld devices or battery packs that...

  20. 75 FR 43206 - In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld...

    Science.gov (United States)

    2010-07-23

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-706] In the Matter of Certain Wireless Communications System Server Software, Wireless Handheld Devices and Battery Packs: Notice of Commission... United States after importation of certain wireless communications system server software, wireless...

  1. Energy harvesting for wireless sensors by using piezoelectric transducers

    Energy Technology Data Exchange (ETDEWEB)

    Duerager, Christian [Empa, Swiss Federal Laboratories for Materials Science and Technology, Duebendorf (Switzerland)

    2012-07-01

    Wireless sensor technology, which integrates transducers, measurement electronics and wireless communication, has become increasingly vital in structural health monitoring (SHM) applications. Compared to traditional wired systems, wireless solutions reduce the installation time and costs and are not subjected to breakage caused by harsh weather conditions or other extreme events. Because of the low installation costs, wireless sensor networks allow the deployment of a big number of wireless sensor nodes on the structures. Moreover, the nodes can be placed on particularly critical components of the structure difficult to reach by wires. In most of the cases the power supply are conventional batteries, which could be a problem because of their finite life span. Furthermore, in the case of wireless sensor nodes located on structures, it is often advantageous to embed them, which makes an access impossible. Therefore, if a method of obtaining the untapped energy surrounding these sensors was implemented, significant life could be added to the power supply. Various approaches to energy harvesting and energy storage are discussed and limitations associated with the current technology are addressed. In this paper we first discuss the research that has been performed in the area of energy harvesting for wireless sensor technologies by using the ambient vibration energy. In many cases the energy produced by the ambient vibrations is far too small to directly power a wireless sensor node. Therefore, in a second step we discuss the development process for an electronic energy harvesting circuit optimized for piezoelectric transducers. In the last part of this paper an experiment with different piezoelectric transducers and their applicability for energy harvesting applications on vibrating structures will be discussed. (orig.)

  2. Resource management in wireless networking

    CERN Document Server

    Cardei, Mihaela; Du, Ding-Zhu

    2005-01-01

    This is the first book that provides readers with a deep technical overview of recent advances in resource management for wireless networks at different layers of the protocol stack. The subject is explored in various wireless networks, such as ad hoc wireless networks, 3G/4G cellular, IEEE 802.11, and Bluetooth personal area networks.Survey chapters give an excellent introduction to key topics in resource management for wireless networks, while experts will be satisfied by the technical depth of the knowledge imparted in chapters exploring hot research topics.The subject area discussed in this book is very relevant today, considering the recent remarkable growth of wireless networking and the convergence of wireless personal communications, internet technologies and real-time multimedia.This volume is a very good companion for practitioners working on implementing solutions for multimedia and Quality of Service - sensitive applications over wireless networks.Written for:Researchers, faculty members, students...

  3. Experience of wireless local area network in a radiation oncology department

    Directory of Open Access Journals (Sweden)

    Mandal Abhijit

    2010-01-01

    Full Text Available The aim of this work is to develop a wireless local area network (LAN between different types of users (Radiation Oncologists, Radiological Physicists, Radiation Technologists, etc for efficient patient data management and to made easy the availability of information (chair side to improve the quality of patient care in Radiation Oncology department. We have used mobile workstations (Laptops and stationary workstations, all equipped with wireless-fidelity (Wi-Fi access. Wireless standard 802.11g (as recommended by Institute of Electrical and Electronic Engineers (IEEE, Piscataway, NJ has been used. The wireless networking was configured with the Service Set Identifier (SSID, Media Access Control (MAC address filtering, and Wired Equivalent Privacy (WEP network securities. We are successfully using this wireless network in sharing the indigenously developed patient information management software. The proper selection of the hardware and the software combined with a secure wireless LAN setup will lead to a more efficient and productive radiation oncology department.

  4. Monitoring Spacecraft Telemetry Via Optical or RF Link

    Science.gov (United States)

    Fielhauer, K. B.; Boone, B. G.

    2011-01-01

    A patent disclosure document discusses a photonic method for connecting a spacecraft with a launch vehicle upper-stage telemetry system as a means for monitoring a spacecraft fs health and status during and right after separation and deployment. This method also provides an efficient opto-coupled capability for prelaunch built-in-test (BIT) on the ground to enable more efficient and timely integration, preflight checkout, and a means to obviate any local EMI (electromagnetic interference) during integration and test. Additional utility can be envisioned for BIT on other platforms, such as the International Space Station (ISS). The photonic telemetry system implements an optical free-space link with a divergent laser transmitter beam spoiled over a significant cone angle to accommodate changes in spacecraft position without having to angle track it during deployment. Since the spacecraft may lose attitude control and tumble during deployment, the transmitted laser beam interrogates any one of several low-profile meso-scale retro-reflective spatial light modulators (SLMs) deployed over the surface of the spacecraft. The return signal beam, modulated by the SLMs, contains health, status, and attitude information received back at the launch vehicle. Very compact low-power opto-coupler technology already exists for the received signal (requiring relatively low bandwidths, e.g., .200 kbps) to enable transfer to a forward pass RF relay from the launch vehicle to TDRSS (Tracking and Data Relay Satellite System) or another recipient. The link would be active during separation and post-separation to monitor spacecraft health, status, attitude, or other data inventories until attitude recovery and ground control can be re-established. An optical link would not interfere with the existing upper stage telemetry and beacon systems, thus meeting launch vehicle EMI environmental constraints.

  5. Intraperitoneal implantation of life-long telemetry transmitters in otariids

    Directory of Open Access Journals (Sweden)

    Haulena Martin

    2008-12-01

    Full Text Available Abstract Background Pinnipeds, including many endangered and declining species, are inaccessible and difficult to monitor for extended periods using externally attached telemetry devices that are shed during the annual molt. Archival satellite transmitters were implanted intraperitoneally into four rehabilitated California sea lions (Zalophus californianus and 15 wild juvenile Steller sea lions (Eumetopias jubatus to determine the viability of this surgical technique for the deployment of long-term telemetry devices in otariids. The life history transmitters record information throughout the life of the host and transmit data to orbiting satellites after extrusion following death of the host. Results Surgeries were performed under isoflurane anesthesia and single (n = 4 or dual (n = 15 transmitters were inserted into the ventrocaudal abdominal cavity via an 8.5 to 12 cm incision along the ventral midline between the umbilicus and pubic symphysis or preputial opening. Surgeries lasted 90 minutes (SD = 8 for the 19 sea lions. All animals recovered well and were released into the wild after extended monitoring periods from 27 to 69 days at two captive animal facilities. Minimum post-implant survival was determined via post-release tracking using externally attached satellite transmitters or via opportunistic re-sighting for mean durations of 73.7 days (SE = 9.0, Z. californianus and 223.6 days (SE = 71.5, E. jubatus. Conclusion The low morbidity and zero mortality encountered during captive observation and post-release tracking periods confirm the viability of this surgical technique for the implantation of long-term telemetry devices in otariids.

  6. Wireless Distributed Antenna MIMO

    DEFF Research Database (Denmark)

    2015-01-01

    The present disclosure relates to system applications of multicore optical fibers. One embodiment relates to a base transceiver station for a wireless telecommunication system comprising a plurality of antenna units arranged in a MIMO configuration and adapted for transmission and/or reception...

  7. Networking wireless sensors

    National Research Council Canada - National Science Library

    Krishnamachari, Bhaskar

    2005-01-01

    ... by networking techniques across multiple layers. The topics covered include network deployment, localization, time synchronization, wireless radio characteristics, medium-access, topology control, routing, data-centric techniques, and transport protocols. Ideal for researchers and designers seeking to create new algorithms and protocols and enginee...

  8. Wireless Remote Control System

    Directory of Open Access Journals (Sweden)

    Adrian Tigauan

    2012-06-01

    Full Text Available This paper presents the design of a wireless remote control system based on the ZigBee communication protocol. Gathering data from sensors or performing control tasks through wireless communication is advantageous in situations in which the use of cables is impractical. An Atmega328 microcontroller (from slave device is used for gathering data from the sensors and transmitting it to a coordinator device with the help of the XBee modules. The ZigBee standard is suitable for low-cost, low-data-rate and low-power wireless networks implementations. The XBee-PRO module, designed to meet ZigBee standards, requires minimal power for reliable data exchange between devices over a distance of up to 1600m outdoors. A key component of the ZigBee protocol is the ability to support networking and this can be used in a wireless remote control system. This system may be employed e.g. to control temperature and humidity (SHT11 sensor and light intensity (TSL230 sensor levels inside a commercial greenhouse.

  9. Subsurface Wireless Sensor Networks

    Science.gov (United States)

    Niemeier, J. J.; Davies, J. L.; Kruger, A.

    2008-12-01

    Conventional thinking holds that underground- and underwater radio communication is not possible, except at very low frequencies employing very long antennas and high transmit power. However, researchers at The University of Iowa have demonstrated that using inexpensive, low-power radios, it is in fact possible to achieve reliable underground radio communication over distances of several meters. This allows for creating underground wireless sensor networks. A proof-of-concept network was established at The University of Iowa, where nodes that measure soil moisture content are buried over a 20×20 m area (up to 1 m deep). The nodes organize themselves into a wireless sensor network, reconfigure routes as radio link quality waxes and wanes, cooperate in routing data packets to a surface base station, and so on. In an agricultural research setting, an advantage of such buried wireless sensor networks is that, if nodes were buried deep enough, they may be left in place during agricultural field work. Power consumption is an important issue in wireless sensor networks. This is especially true in a buried network where battery replacement is a major undertaking. The focus of continuing research is developing methods of inductively recharging buried sensor batteries.

  10. Insecurity of Wireless Networks

    Energy Technology Data Exchange (ETDEWEB)

    Sheldon, Frederick T [ORNL; Weber, John Mark [Dynetics, Inc.; Yoo, Seong-Moo [University of Alabama, Huntsville; Pan, W. David [University of Alabama, Huntsville

    2012-01-01

    Wireless is a powerful core technology enabling our global digital infrastructure. Wi-Fi networks are susceptible to attacks on Wired Equivalency Privacy, Wi-Fi Protected Access (WPA), and WPA2. These attack signatures can be profiled into a system that defends against such attacks on the basis of their inherent characteristics. Wi-Fi is the standard protocol for wireless networks used extensively in US critical infrastructures. Since the Wired Equivalency Privacy (WEP) security protocol was broken, the Wi-Fi Protected Access (WPA) protocol has been considered the secure alternative compatible with hardware developed for WEP. However, in November 2008, researchers developed an attack on WPA, allowing forgery of Address Resolution Protocol (ARP) packets. Subsequent enhancements have enabled ARP poisoning, cryptosystem denial of service, and man-in-the-middle attacks. Open source systems and methods (OSSM) have long been used to secure networks against such attacks. This article reviews OSSMs and the results of experimental attacks on WPA. These experiments re-created current attacks in a laboratory setting, recording both wired and wireless traffic. The article discusses methods of intrusion detection and prevention in the context of cyber physical protection of critical Internet infrastructure. The basis for this research is a specialized (and undoubtedly incomplete) taxonomy of Wi-Fi attacks and their adaptations to existing countermeasures and protocol revisions. Ultimately, this article aims to provide a clearer picture of how and why wireless protection protocols and encryption must achieve a more scientific basis for detecting and preventing such attacks.

  11. Wireless networked music performance

    CERN Document Server

    Gabrielli, Leonardo

    2016-01-01

    This book presents a comprehensive overview of the state of the art in Networked Music Performance (NMP) and a historical survey of computer music networking. It introduces current technical trends in NMP and technical issues yet to be addressed. It also lists wireless communication protocols and compares these to the requirements of NMP. Practical use cases and advancements are also discussed.

  12. Apollo 11 Telemetry Data Recordings: A Final Report

    Science.gov (United States)

    2010-01-01

    When astronauts landed on the moon on July 20, 1969, the Eagle lander carried a small, unconventional television camera affixed to the inside of the door. It had one mission. Once astronauts opened the door and activated the camera, it would begin shooting live images of the historic event, transmitting the raw footage by way of an antenna to Earth below. There, engineers at three tracking stations would tape the original signals onto one-inch telemetry tapes fpr backup and then also convert the raw feed into a conventional format compatible with American broadcast standards.

  13. Plant Habitat Telemetry / Command Interface and E-MIST

    Science.gov (United States)

    Walker, Uriae M.

    2013-01-01

    Plant Habitat (PH) is an experiment to be taken to the International Space Station (ISS) in 2016. It is critical that ground support computers have the ability to uplink commands to control PH, and that ISS computers have the ability to downlink PH telemetry data to ground support. This necessitates communication software that can send, receive, and process, PH specific commands and telemetry. The objective of the Plant Habitat Telemetry/ Command Interface is to provide this communication software, and to couple it with an intuitive Graphical User Interface (GUI). Initial investigation of the project objective led to the decision that code be written in C++ because of its compatibility with existing source code infrastructures and robustness. Further investigation led to a determination that multiple Ethernet packet structures would need to be created to effectively transmit data. Setting a standard for packet structures would allow us to distinguish these packets that would range from command type packets to sub categories of telemetry packets. In order to handle this range of packet types, the conclusion was made to take an object-oriented programming approach which complemented our decision to use the C++ programming language. In addition, extensive utilization of port programming concepts was required to implement the core functionality of the communication software. Also, a concrete understanding of a packet processing software was required in order to put aU the components of ISS-to-Ground Support Equipment (GSE) communication together and complete the objective. A second project discussed in this paper is Exposing Microbes to the Stratosphere (EMIST). This project exposes microbes into the stratosphere to observe how they are impacted by atmospheric effects. This paper focuses on the electrical and software expectations of the project, specifically drafting the printed circuit board, and programming the on-board sensors. The Eagle Computer-Aided Drafting

  14. NASA Bluetooth Wireless Communications

    Science.gov (United States)

    Miller, Robert D.

    2007-01-01

    NASA has been interested in wireless communications for many years, especially when the crew size of the International Space Station (ISS) was reduced to two members. NASA began a study to find ways to improve crew efficiency to make sure the ISS could be maintained with limited crew capacity and still be a valuable research testbed in Low-Earth Orbit (LEO). Currently the ISS audio system requires astronauts to be tethered to the audio system, specifically a device called the Audio Terminal Unit (ATU). Wireless communications would remove the tether and allow astronauts to freely float from experiment to experiment without having to worry about moving and reconnecting the associated cabling or finding the space equivalent of an extension cord. A wireless communication system would also improve safety and reduce system susceptibility to Electromagnetic Interference (EMI). Safety would be improved because a crewmember could quickly escape a fire while maintaining communications with the ground and other crewmembers at any location. In addition, it would allow the crew to overcome the volume limitations of the ISS ATU. This is especially important to the Portable Breathing Apparatus (PBA). The next generation of space vehicles and habitats also demand wireless attention. Orion will carry up to six crewmembers in a relatively small cabin. Yet, wireless could become a driving factor to reduce launch weight and increase habitable volume. Six crewmembers, each tethered to a panel, could result in a wiring mess even in nominal operations. In addition to Orion, research is being conducted to determine if Bluetooth is appropriate for Lunar Habitat applications.

  15. Photonic generation for multichannel THz wireless communication.

    Science.gov (United States)

    Shams, Haymen; Fice, Martyn J; Balakier, Katarzyna; Renaud, Cyril C; van Dijk, Frédéric; Seeds, Alwyn J

    2014-09-22

    We experimentally demonstrate photonic generation of a multichannel THz wireless signal at carrier frequency 200 GHz, with data rate up to 75 Gbps in QPSK modulation format, using an optical heterodyne technique and digital coherent detection. BER measurements were carried out for three subcarriers each modulated with 5 Gbaud QPSK or for two subcarriers modulated with 10 Gbaud QPSK, giving a total speed of 30 Gbps or 40 Gbps, respectively. The system evaluation was also performed with three subcarriers modulated with 12.5 Gbaud QPSK (75 Gbps total) without and with 40 km fibre transmission. The proposed system enhances the capacity of high-speed THz wireless transmission by using spectrally efficient modulated subcarriers spaced at the baud rate. This approach increases the overall transmission capacity and reduces the bandwidth requirement for electronic devices.

  16. Sensor Network in the Wireless UHF Band

    Science.gov (United States)

    Mariño, P.; Fontán, F. P.; Domínguez, M. A.; Otero, S.

    Biological research in agriculture needs a lot of specialized electronic sensors in order to fulfill different goals, like as: climate monitoring, soil and fruit assessment, control of insects and diseases, chemical pollutants, identification and control of weeds, crop tracking, and so on. That research must be supported by consistent biological models able to simulate diverse environmental conditions, in order to predict the right human actions before risky biological damage could be irreversible. In this paper an experimental distributed network based on climatic and biological wireless sensors is described, for providing real measurements in order to validate different biological models used for viticulture applications. Firstly the experimental network for field automatic data acquisition is presented, as a system based in a distributed process. Then, the design of the wireless network is explained in detail, with a previous discussion about the state-of-the-art, and some measurements for viticulture research are pointed out. Finally future developments and conclusions are stated.

  17. Wireless information system for frost detection in orchards

    OpenAIRE

    Marković, Dušan B.; Glišić, Ivan P.; Pešović, Uroš M.; Ranđić, Siniša S.

    2013-01-01

    Electronic devices are widely used in many fields and agriculture is also one of the areas with great intensity of applications in the last years. Electronic sensor devices are particularly interesting because they are enable measure of parameters which have a major impact on agriculture production. The use of electronic devices additionally came to the fore with the development of wireless communication that allows gathering timely information about the status of important parameters for veg...

  18. Wireless Sensors and Networks for Advanced Energy Management

    Energy Technology Data Exchange (ETDEWEB)

    Hardy, J.E.

    2005-05-06

    Numerous national studies and working groups have identified low-cost, very low-power wireless sensors and networks as a critical enabling technology for increasing energy efficiency, reducing waste, and optimizing processes. Research areas for developing such sensor and network platforms include microsensor arrays, ultra-low power electronics and signal conditioning, data/control transceivers, and robust wireless networks. A review of some of the research in the following areas will be discussed: (1) Low-cost, flexible multi-sensor array platforms (CO{sub 2}, NO{sub x}, CO, humidity, NH{sub 3}, O{sub 2}, occupancy, etc.) that enable energy and emission reductions in applications such as buildings and manufacturing; (2) Modeling investments (energy usage and savings to drive capital investment decisions) and estimated uptime improvements through pervasive gathering of equipment and process health data and its effects on energy; (3) Robust, self-configuring wireless sensor networks for energy management; and (4) Quality-of-service for secure and reliable data transmission from widely distributed sensors. Wireless communications is poised to support technical innovations in the industrial community, with widespread use of wireless sensors forecasted to improve manufacturing production and energy efficiency and reduce emissions. Progress being made in wireless system components, as described in this paper, is helping bring these projected improvements to reality.

  19. Active learners in sustainable electronics and it

    DEFF Research Database (Denmark)

    Schultz, Ole

    This poster-presentation is about active learning in a course sustainable wireless electronics and it. Active learning understood as practical lab-exercises and a team chosen project.......This poster-presentation is about active learning in a course sustainable wireless electronics and it. Active learning understood as practical lab-exercises and a team chosen project....

  20. [Analysis of telemetry, on-line and non-telemetry data for characterization of the physical activity of patients with heart failure].

    Science.gov (United States)

    Melczer, Csaba; Melczer, László; Goják, Ilona; Kónyi, Attila; Szabados, Sándor; Raposa, László Bence; Oláh, András; Ács, Pongrác

    2017-09-01

    Several studies have demonstrated that the prevalence of heart disease can be accounted for between 0.4 and 2% in developed countries. The present study aimed to use the PA% of the telemetry data to estimate the 6-minute walk test result. A total of seventeen patients with heart disease; 3 females and 14 males; age: 57.35 yrs ± 9.54; body mass 98.71 ± 9.89 kg; average BMI 36.69 ± 3.67 were recruited into the study. Using the two sets of values describing physical performance, linear regression was calculated providing a mathematical equation, thus, the Physical Activity % value is used to estimate the distance traveled over a 6-minute walk test. On further data analysis, we have come to the conclusion that the distance walked during the six-minute-long test may be measured by PA% from the data of CRT device. With our method, based on the values received from the physical activity sensor implanted into the resynchronisation devices, changes in patients' health status could be monitored telemetrically with the assistance from the implanted electronic device. Orv Hetil. 2017; 158(35): 1390-1395.

  1. Acoustic telemetry reveals cryptic residency of whale sharks.

    Science.gov (United States)

    Cagua, E Fernando; Cochran, Jesse E M; Rohner, Christoph A; Prebble, Clare E M; Sinclair-Taylor, Tane H; Pierce, Simon J; Berumen, Michael L

    2015-04-01

    Although whale sharks (Rhincodon typus) have been documented to move thousands of kilometres, they are most frequently observed at a few predictable seasonal aggregation sites. The absence of sharks at the surface during visual surveys has led to the assumption that sharks disperse to places unknown during the long 'off-seasons' at most of these locations. Here we compare 2 years of R. typus visual sighting records from Mafia Island in Tanzania to concurrent acoustic telemetry of tagged individuals. Sightings revealed a clear seasonal pattern with a peak between October and February and no sharks observed at other times. By contrast, acoustic telemetry demonstrated year-round residency of R. typus. The sharks use a different habitat in the off-season, swimming deeper and further away from shore, presumably in response to prey distributions. This behavioural change reduces the sharks' visibility, giving the false impression that they have left the area. We demonstrate, for the first time to our knowledge, year-round residency of unprovisioned, individual R. typus at an aggregation site, and highlight the importance of using multiple techniques to study the movement ecology of marine megafauna. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  2. Acoustic telemetry reveals cryptic residency of whale sharks

    KAUST Repository

    Cagua, Edgar F.

    2015-04-01

    Althoughwhale sharks (Rhincodon typus) have beendocumentedtomove thousands of kilometres, they are most frequently observed at a few predictable seasonal aggregation sites. The absence of sharks at the surface during visual surveys has led to the assumption that sharks disperse to places unknown during the long \\'off-seasons\\' at most of these locations. Here we compare 2 years of R. typus visual sighting records from Mafia Island in Tanzania to concurrent acoustic telemetry of tagged individuals. Sightings revealed a clear seasonal pattern with a peak between October and February and no sharks observed at other times. By contrast, acoustic telemetry demonstrated yearround residency of R. typus. The sharks use a different habitat in the offseason, swimming deeper and further away from shore, presumably in response to prey distributions. This behavioural change reduces the sharks\\' visibility, giving the false impression that they have left the area.We demonstrate, for the first timeto our knowledge, year-roundresidencyofunprovisioned, individual R. typus at an aggregation site, and highlight the importance of using multiple techniques to study the movement ecology of marine megafauna. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  3. Florida Atlantic Coast Telemetry (FACT) Array: A Working Partnership

    Science.gov (United States)

    Scheidt, Douglas; Ault, Erick; Ellis, Robert D.; Gruber, Samuel; Iafrate, Joseph; Kalinowsky, Chris; Kessel, Steven; Reyier, Eric; Snyder, David; Watwood, Stephanie; hide

    2015-01-01

    The Florida Atlantic Coast Telemetry (FACT) Array is a collaborative partnership of researchers from 24 different organizations using passive acoustic telemetry to document site fidelity, habitat preferences, seasonal migration patterns, and reproductive strategies of valuable sportfish, sharks, and marine turtles. FACT partners have found that by bundling resources, they can leverage a smaller investment to track highly mobile animals beyond a study area typically restrained in scale by funds and manpower. FACT is guided by several simple rules: use of the same type of equipment, locate receivers in areas that are beneficial to all researchers when feasible, maintain strong scientific ethics by recognizing that detection data on any receiver belongs to the tag owner, do not use other members detection data without permission and acknowledge FACT in publications. Partners have access to a network of 480 receivers deployed along a continuum of habitats from freshwater rivers to offshore reefs and covers 1100 km of coastline from the Dry Tortugas, Florida to South Carolina and extends to the Bahamas. Presently, 49 species, (25 covered by Fisheries Management Plans and five covered by the Endangered Species Act) have been tagged with 2736 tags in which 1767 tags are still active.

  4. Acoustic telemetry reveals cryptic residency of whale sharks

    Science.gov (United States)

    Cagua, E. Fernando; Cochran, Jesse E. M.; Rohner, Christoph A.; Prebble, Clare E. M.; Sinclair-Taylor, Tane H.; Pierce, Simon J.; Berumen, Michael L.

    2015-01-01

    Although whale sharks (Rhincodon typus) have been documented to move thousands of kilometres, they are most frequently observed at a few predictable seasonal aggregation sites. The absence of sharks at the surface during visual surveys has led to the assumption that sharks disperse to places unknown during the long ‘off-seasons’ at most of these locations. Here we compare 2 years of R. typus visual sighting records from Mafia Island in Tanzania to concurrent acoustic telemetry of tagged individuals. Sightings revealed a clear seasonal pattern with a peak between October and February and no sharks observed at other times. By contrast, acoustic telemetry demonstrated year-round residency of R. typus. The sharks use a different habitat in the off-season, swimming deeper and further away from shore, presumably in response to prey distributions. This behavioural change reduces the sharks' visibility, giving the false impression that they have left the area. We demonstrate, for the first time to our knowledge, year-round residency of unprovisioned, individual R. typus at an aggregation site, and highlight the importance of using multiple techniques to study the movement ecology of marine megafauna. PMID:25832816

  5. Instrumentation and Baseband Telemetry for RLV-TD HEX Mission

    Science.gov (United States)

    Jose, Smitha; Varghese, Bibin; Chauhan, Akshay; Elizabeth, Sheba; Sreelal, S.; Sreekumar, S.; Vinod, P.; Mookiah, T.

    2017-12-01

    In this work, the salient requirements and features of the baseband telemetry system used in Reusable Launch Vehicle—Technology Demonstrator Hypersonic Experiment mission are discussed. The configuration of the overall system, subsystem components and their features are described in brief. The unique requirements of the telemetry system, when compared to that in a conventional launch vehicle, by way of a large number of temperature and strain measurements that enable the assessment of structural integrity and mission performance in re-entry mission, are dealt with, along with the system configuration to cater to these. Subsequently, two new units have been described—Strain Data Acquisition Unit and Multiplexed Data Acquisition Unit that were inducted specifically to cater to strain measurements using strain gauges and temperature measurements using thermocouples respectively. The optimized subsystem configurations for these units are described and their field performance during flight is analyzed. This work further discusses a novel method of data recovery for those measurements affected by the baseline offset shift caused by the presence of a chassis voltage and poor isolation of sensor to chassis.

  6. 11th International Conference On Broad-Band Wireless Computing, Communication and Applications

    CERN Document Server

    Xhafa, Fatos; Yim, Kangbin

    2017-01-01

    The success of all-IP networking and wireless technology has changed the ways of living the people around the world. The progress of electronic integration and wireless communications is going to pave the way to offer people the access to the wireless networks on the fly, based on which all electronic devices will be able to exchange the information with each other in ubiquitous way whenever necessary. The aim of the volume is to provide latest research findings, innovative research results, methods and development techniques from both theoretical and practical perspectives related to the emerging areas of broadband and wireless computing. This proceedings volume presents the results of the 11th International Conference on Broad-Band Wireless Computing, Communication And Applications (BWCCA-2016), held November 5-7, 2016, at Soonchunhyang University, Asan, Korea. .

  7. Micro package of short term wireless implantable microfabricated systems.

    Science.gov (United States)

    Bu, Leping; Cong, Peng; Kuo, Hung-I; Ye, Xuesong; Ko, Wen

    2009-01-01

    Package is a critical part in biomedical implantable systems. Many factors affecting the host body and the life time of implantable systems need to be considered. Package becomes more critical for microfabricated systems with wireless charging and communication. This paper presents the first phase study on micro package techniques for short term (30 to 90 days) implantable systems. A MEMS implantable telemetry model system was designed for packaging evaluation. The transmitter was custom designed and fabricated using MOSIS processes and an external receiver was designed and built for data collection. For short term implantable systems, medical grade silicone outer coating is used for "tissue compatibility"; while multilayer polymeric and nanometer-thin metal or ceramic films were used for inner coatings to provide mechanical strength and to block vapor and moisture penetration. The total coating thickness is less than 0.6 mm. The electrical performances (leakage resistance) of test board and model devices coated with various package materials and processes are evaluated in 40 degrees C saline. This paper presents: the model system; the evaluation methods and analysis of failure modes of polymeric coating on test boards; the solution to the failures and suggested coating techniques of polymeric materials; and the evaluation of model systems packaged with multi-layer coatings in 40 degrees C saline. The expected performance of developed packaging method was verified by experiments. Implantable wireless MEMS system can be packaged with thin multilayer materials to have an expected life time greater than 30 days.

  8. Guidelines for wireless technology in nuclear power plants

    International Nuclear Information System (INIS)

    Shankar, Ramesh

    2003-01-01

    As a result of technological breakthroughs, increased demand for the use of wireless technology is common in all industries today, and the electric power industry is no exception. Already, wireless technology has many applications in our industry, including - but not limited to - cellular phone systems, paging systems, two-way radio communication systems, dose management and tracking systems, and operator logs. EPRI has prepared a comprehensive guidelines document to support evaluation of wireless technologies in power plants for integrated (voice/data/video) communication, remote equipment and system monitoring, and to complement an electronic procedures support system (EPSS). The guidelines effort focuses on the development of a rules structure to support the deployment of wireless devices in a plant without compromising continuous, safe, and reliable operation. The guidelines document consists of two volumes. The first volume is introductory in nature and lays out the business case for applying wireless technologies. The intended audience is senior plant management personnel and utility industry executives. This volume contains background information, templates, worksheets, processes, and presentations that will allow internal sponsors to create business cases for piloting wireless projects. The second volume includes guidance on implementation and regulatory issues relevant to plant implementation. It covers the following application areas: implementation of integrated communication capability, equipment monitoring, work quality control, time and knowledge management, and business process automation. It details regulatory issues relevant to the adoption of wireless technology within nuclear power plants and offers guidance on preparing for and executing pilot and implementations of wireless technologies. The paper will cover important aspects on the guidelines. (author)

  9. The Lure of Wireless Encryption

    CERN Multimedia

    Computer Security Team

    2013-01-01

    Following our article entitled “Jekyll or Hyde? Better browse securely” in the last issue of the Bulletin, some people wondered why the CERN wireless network is not encrypted…   There are many arguments why it is not. The simplest is usability: the communication and management of the corresponding access keys would be challenging given the sheer number of wireless devices the CERN network hosts. Keys would quickly become public, e.g. at conferences, and might be shared, written on whiteboards, etc. Then there are all the devices which cannot be easily configured to use encryption protocols - a fact which would create plenty of calls to the CERN Service Desk… But our main argument is that wireless encryption is DECEPTIVE. Wireless encryption is deceptive as it only protects the wireless network against unauthorised access (and the CERN network already has other means to protect against that). Wireless encryption however, does not really help you. You ...

  10. Matching theory for wireless networks

    CERN Document Server

    Han, Zhu; Saad, Walid

    2017-01-01

    This book provides the fundamental knowledge of the classical matching theory problems. It builds up the bridge between the matching theory and the 5G wireless communication resource allocation problems. The potentials and challenges of implementing the semi-distributive matching theory framework into the wireless resource allocations are analyzed both theoretically and through implementation examples. Academics, researchers, engineers, and so on, who are interested in efficient distributive wireless resource allocation solutions, will find this book to be an exceptional resource. .

  11. An Assessment of Emerging Wireless Broadband Technologies

    National Research Council Canada - National Science Library

    Fountanas, Leonidas

    2001-01-01

    ... technologies in providing broadband services today, emerging wireless broadband technologies are expected to significantly increase their market share over the next years, Deploying a wireless network...

  12. Wireless Sensor Portal Technology Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Recognizing the needs and challenges facing NASA Earth Science for data input, manipulation and distribution, Mobitrum is proposing a ? Wireless Sensor Portal...

  13. Adaptive Wireless Transceiver, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Wireless technologies are an increasingly attractive means for spatial data, input, manipulation, and distribution. Mobitrum is proposing an innovative Adaptive...

  14. Smart Home Wireless Sensor Nodes

    DEFF Research Database (Denmark)

    Lynggaard, Per

    Smart homes are further development of intelligent buildings and home automation, where context awareness and autonomous behaviour are added. They are based on a combination of the Internet and emerging technologies like wireless sensor nodes. These wireless sensor nodes are challenging because....... This paper introduces an approach that considerably lowers the wireless sensor node power consumption and the amount of transmitted sensor events. It uses smart objects that include artificial intelligence to efficiently process the sensor event on location and thereby saves the costly wireless...

  15. Some Challenges in Wireless Security

    National Research Council Canada - National Science Library

    Banerjee, Suman

    2007-01-01

    Wireless communication technologies provide users with significant flexibility and portability and hence is being widely adopted as a preferred mode of communication in many military and civilian applications...

  16. Smart Home Wireless Sensor Nodes

    DEFF Research Database (Denmark)

    Lynggaard, Per

    . This paper introduces an approach that considerably lowers the wireless sensor node power consumption and the amount of transmitted sensor events. It uses smart objects that include artificial intelligence to efficiently process the sensor event on location and thereby saves the costly wireless......Smart homes are further development of intelligent buildings and home automation, where context awareness and autonomous behaviour are added. They are based on a combination of the Internet and emerging technologies like wireless sensor nodes. These wireless sensor nodes are challenging because...

  17. Non-critical care telemetry and in-hospital cardiac arrest outcomes.

    Science.gov (United States)

    Mohammad, Rami; Shah, Sachil; Donath, Elie; Hartmann, Nicholas; Rasmussen, Ann; Isaac, Shaun; Borzak, Steven

    2015-01-01

    Telemetry is increasingly used to monitor hospitalized patients with lower intensities of care, but its effect on in-hospital cardiac arrest (IHCA) outcomes in non-critical care patients is unknown. Telemetry utilization in non-critical care patients does not affect IHCA outcomes. A retrospective cohort analysis of all patients in non-critical care beds that experienced a cardiac arrest in a university-affiliated teaching hospital during calendar years 2011 and 2012 was performed. Data were collected as part of AHA Get With the Guidelines protocol. The independent variable and exposure studied were whether patients were on telemetry or not. Telemetry was monitored from a central location. The primary endpoint was return of spontaneous circulation (ROSC) and the secondary end point was survival to discharge. Of 123 IHCA patients, the mean age was 75±15 and 74 (61%) were male. 80 (65%) patients were on telemetry. Baseline demographics were similar except for age; patients on telemetry were younger with mean age of 70.3 vs. 76.8 in the non-telemetry group (p=0.024). 72 patients (60%) achieved ROSC and 46 (37%) achieved survival to discharge. By univariate analysis, there was no difference between patients that had been on telemetry vs. no telemetry in ROSC (OR=1.13, p=0.76) or survival to discharge (OR=1.18, p=0.67). Similar findings were obtained with multivariate analysis for ROSC (0.91, p=0.85) and survival to discharge (OR=0.92, p=0.87). The use of cardiac telemetry in non-critical care beds, when monitored remotely in a central location, is not associated with improved IHCA outcomes. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Cognitive wireless networks

    CERN Document Server

    Feng, Zhiyong; Zhang, Ping

    2015-01-01

    This brief examines the current research in cognitive wireless networks (CWNs). Along with a review of challenges in CWNs, this brief presents novel theoretical studies and architecture models for CWNs, advances in the cognitive information awareness and delivery, and intelligent resource management technologies. The brief presents the motivations and concepts of CWNs, including theoretical studies of temporal and geographic distribution entropy as well as cognitive information metrics. A new architecture model of CWNs is proposed with theoretical, functional and deployment architectures suppo

  19. A low-power bidirectional telemetry device with a near-field charging feature for a cardiac microstimulator.

    Science.gov (United States)

    Shuenn-Yuh Lee; Chih-Jen Cheng; Ming-Chun Liang

    2011-08-01

    In this paper, wireless telemetry using the near-field coupling technique with round-wire coils for an implanted cardiac microstimulator is presented. The proposed system possesses an external powering amplifier and an internal bidirectional microstimulator. The energy of the microstimulator is provided by a rectifier that can efficiently charge a rechargeable device. A fully integrated regulator and a charge pump circuit are included to generate a stable, low-voltage, and high-potential supply voltage, respectively. A miniature digital processor includes a phase-shift-keying (PSK) demodulator to decode the transmission data and a self-protective system controller to operate the entire system. To acquire the cardiac signal, a low-voltage and low-power monitoring analog front end (MAFE) performs immediate threshold detection and data conversion. In addition, the pacing circuit, which consists of a pulse generator (PG) and its digital-to-analog (D/A) controller, is responsible for stimulating heart tissue. The chip was fabricated by Taiwan Semiconductor Manufacturing Company (TSMC) with 0.35-μm complementary metal-oxide semiconductor technology to perform the monitoring and pacing functions with inductively powered communication. Using a model with lead and heart tissue on measurement, a -5-V pulse at a stimulating frequency of 60 beats per minute (bpm) is delivered while only consuming 31.5 μW of power.

  20. Wireless laptop-based phonocardiograph and diagnosis

    Directory of Open Access Journals (Sweden)

    Amy T. Dao

    2015-08-01

    Full Text Available Auscultation is used to evaluate heart health, and can indicate when it’s needed to refer a patient to a cardiologist. Advanced phonocardiograph (PCG signal processing algorithms are developed to assist the physician in the initial diagnosis but they are primarily designed and demonstrated with research quality equipment. Therefore, there is a need to demonstrate the applicability of those techniques with consumer grade instrument. Furthermore, routine monitoring would benefit from a wireless PCG sensor that allows continuous monitoring of cardiac signals of patients in physical activity, e.g., treadmill or weight exercise. In this work, a low-cost portable and wireless healthcare monitoring system based on PCG signal is implemented to validate and evaluate the most advanced algorithms. Off-the-shelf electronics and a notebook PC are used with MATLAB codes to record and analyze PCG signals which are collected with a notebook computer in tethered and wireless mode. Physiological parameters based on the S1 and S2 signals and MATLAB codes are demonstrated. While the prototype is based on MATLAB, the later is not an absolute requirement.

  1. Deep Space Habitat Wireless Smart Plug

    Science.gov (United States)

    Morgan, Joseph A.; Porter, Jay; Rojdev, Kristina; Carrejo, Daniel B.; Colozza, Anthony J.

    2014-01-01

    NASA has been interested in technology development for deep space exploration, and one avenue of developing these technologies is via the eXploration Habitat (X-Hab) Academic Innovation Challenge. In 2013, NASA's Deep Space Habitat (DSH) project was in need of sensors that could monitor the power consumption of various devices in the habitat with added capability to control the power to these devices for load shedding in emergency situations. Texas A&M University's Electronic Systems Engineering Technology Program (ESET) in conjunction with their Mobile Integrated Solutions Laboratory (MISL) accepted this challenge, and over the course of 2013, several undergraduate students in a Capstone design course developed five wireless DC Smart Plugs for NASA. The wireless DC Smart Plugs developed by Texas A&M in conjunction with NASA's Deep Space Habitat team is a first step in developing wireless instrumentation for future flight hardware. This paper will further discuss the X-Hab challenge and requirements set out by NASA, the detailed design and testing performed by Texas A&M, challenges faced by the team and lessons learned, and potential future work on this design.

  2. Getting ahead of the curve in wireless communications | CRDI ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    The project aims to: develop improved and affordable wireless technologies that are adapted to the context of developing countries;; train graduate students in ... Government of India, he also received the Hari Om Ashram Prerit Dr. Vikram Sarabhai Research Award in electronics, telematics, informatics, and automation.

  3. Miniaturized Blood Pressure Telemetry System with RFID Interface

    Directory of Open Access Journals (Sweden)

    Michele Caldara

    2016-08-01

    Full Text Available This work deals with the development and characterization of a potentially implantable blood pressure telemetry system, based on an active Radio-Frequency IDentification (RFID tag, International Organization for Standardization (ISO 15693 compliant. This approach aims to continuously measure the average, systolic and diastolic blood pressure of the small/medium animals. The measured pressure wave undergoes embedded processing and results are stored onboard in a non-volatile memory, providing the data under interrogation by an external RFID reader. In order to extend battery lifetime, RFID energy harvesting has been investigated. The paper presents the experimental characterization in a laboratory and preliminary in-vivo tests. The device is a prototype mainly intended, in a future engineered version, for monitoring freely moving test animals for pharmaceutical research and drug safety assessment purposes, but it could have multiple uses in environmental and industrial applications.

  4. GlastCam: A Telemetry-Driven Spacecraft Visualization Tool

    Science.gov (United States)

    Stoneking, Eric T.; Tsai, Dean

    2009-01-01

    Developed for the GLAST project, which is now the Fermi Gamma-ray Space Telescope, GlastCam software ingests telemetry from the Integrated Test and Operations System (ITOS) and generates four graphical displays of geometric properties in real time, allowing visual assessment of the attitude, configuration, position, and various cross-checks. Four windows are displayed: a "cam" window shows a 3D view of the satellite; a second window shows the standard position plot of the satellite on a Mercator map of the Earth; a third window displays star tracker fields of view, showing which stars are visible from the spacecraft in order to verify star tracking; and the fourth window depicts

  5. Architecture and performances of the AGILE Telemetry Preprocessing System (TMPPS)

    Science.gov (United States)

    Trifoglio, M.; Bulgarelli, A.; Gianotti, F.; Lazzarotto, F.; Di Cocco, G.; Fuschino, F.; Tavani, M.

    2008-07-01

    AGILE is an Italian Space Agency (ASI) satellite dedicated to high energy Astrophysics. It was launched successfully on 23 April 2007, and it has been operated by the AGILE Ground Segment, consisting of the Ground Station located in Malindi (Kenia), the Mission Operations Centre (MOC) and the AGILE Data Centre (ADC) established in Italy, at Telespazio in Fucino and at the ASI Science Data Centre (ASDC) in Frascati respectively. Due to the low equatorial orbit at ~ 530 Km. with inclination angle of ~ 2.5°, the satellite passes over the Ground Station every ~ 100'. During the visibility period of . ~ 12', the Telemetry (TM) is down linked through two separated virtual channels, VC0 and VC1. The former is devoted to the real time TM generated during the pass at the average rate of 50 Kbit/s and is directly relayed to the Control Centre. The latter is used to downlink TM data collected on the satellite on-board mass memory during the non visibility period. This generates at the Ground Station a raw TM file of up to 37 MByte. Within 20' after the end of the contact, both the real time and mass memory TM arrive at ADC through the dedicated VPN ASINet. Here they are automatically detected and ingested by the TMPPS pipeline in less than 5 minutes. The TMPPS archives each TM file and sorts its packets into one stream for each of the different TM layout. Each stream is processed in parallel in order to unpack the various telemetry field and archive them into suitable FITS files. Each operation is tracked into a MySQL data base which interfaces the TMPPS pipeline to the rest of the scientific pipeline running at ADC. In this paper the architecture and the performance of the TMPPS will be described and discussed.

  6. iSAT: The Integrated Satellite and Acoustic Telemetry system for tracking marine megafauna

    KAUST Repository

    De La Torre, Pedro R.

    2014-05-01

    In this dissertation an innovative technology to study whale sharks, Rhincodon typus is presented. The Integrated Satellite and Acoustic Telemetry project (iSAT) combines underwater acoustic telemetry, autonomous navigation and radio frequency communications into a standalone system. The whale shark, a resident of the Saudi Arabian Red Sea, is the target of the study. The technology presented is designed to help close current gaps in the knowledge of whale shark biology; these are gaps that prohibit the design of optimal conservation strategies. Unfortunately, the various existing tracking technologies each have limitations and are unable to solve all the unanswered questions. Whale shark populations are increasingly threatened by anthropogenic activities such as targeted and indirect fishing pressure, creating an urgent need for better management practices. This dissertation addresses the current state-of-the-art of relevant technologies, including autonomous surface vehicles (ASVs), sensors for research in the ocean and remote monitoring of wild fauna (biotelemetry). iSAT contains components of all of these technologies, but the primary achievement of this dissertation is the development of iSAT’s Acoustic Tracking System (ATS). Underwater, the most efficient way of transmitting energy through long distances is sound. An electronic tag is attached to an animal and works as its acoustic identifier. iSAT’s hydrophone array detects the presence and direction of the acoustic signal generated by the tag. The expected performance, range, and capacity to tell the direction to the tag are explained and compared to the actual measured values. The first operational iSAT ATS is demonstrated. This work represents significant advancement towards a fully autonomous iSAT system. Developments on the power electronics, navigation, renewable energy harvesting, and other modules are included in this research. With the recent integration of digital acquisition systems, i

  7. Making Wireless Networks Secure for NASA Mission Critical Applications Using Virtual Private Network (VPN) Technology

    Science.gov (United States)

    Nichols, Kelvin F.; Best, Susan; Schneider, Larry

    2004-01-01

    With so many security issues involved with wireless networks, the technology has not been fully utilized in the area of mission critical applications. These applications would include the areas of telemetry, commanding, voice and video. Wireless networking would allow payload operators the mobility to take computers outside of the control room to their off ices and anywhere else in the facility that the wireless network was extended. But the risk is too great of having someone sit just inside of your wireless network coverage and intercept enough of your network traffic to steal proprietary data from a payload experiment or worse yet hack back into your system and do even greater harm by issuing harmful commands. Wired Equivalent Privacy (WEP) is improving but has a ways to go before it can be trusted to protect mission critical data. Today s hackers are becoming more aggressive and innovative, and in order to take advantage of the benefits that wireless networking offer, appropriate security measures need to be in place that will thwart hackers. The Virtual Private Network (VPN) offers a solution to the security problems that have kept wireless networks from being used for mission critical applications. VPN provides a level of encryption that will ensure that data is protected while it is being transmitted over a wireless local area network (LAN). The VPN allows a user to authenticate to the site that the user needs to access. Once this authentication has taken place the network traffic between that site and the user is encapsulated in VPN packets with the Triple Data Encryption Standard (3DES). 3DES is an encryption standard that uses a single secret key to encrypt and decrypt data. The length of the encryption key is 168 bits as opposed to its predecessor DES that has a 56-bit encryption key. Even though 3DES is the common encryption standard for today, the Advance Encryption Standard (AES), which provides even better encryption at a lower cycle cost is growing

  8. Green Wireless Power Transfer Networks

    NARCIS (Netherlands)

    Liu, Q.; Golinnski, M.; Pawelczak, P.; Warnier, M.

    2016-01-01

    wireless power transfer network (WPTN) aims to support devices with cable-less energy on-demand. Unfortunately, wireless power transfer itself-especially through radio frequency radiation rectification-is fairly inefficient due to decaying power with distance, antenna polarization, etc.

  9. Wireless Networks: a brief introduction

    Indian Academy of Sciences (India)

    First page Back Continue Last page Overview Graphics. Wireless Networks: a brief introduction. Wireless communication: What? Why? How many types? What is cell? Is it different from fixed landline structure? 1G systems: FDMA/FDD and Analog FM [voice comm]. (Introduced in 1983 in Chicago by AMPS). 2G systems: 3 ...

  10. An Analysis Of Wireless Security

    OpenAIRE

    Salendra Prasad

    2017-01-01

    The WLAN security includes Wired Equivalent Primary WEP and WI-FI protected Access WPA. Today WEP is regarded as very poor security standard. WEP was regarded as very old security standard and has many security issues which users need to be addressed. In this Paper we will discuss Wireless Security and ways to improve on wireless security.

  11. Preliminary PANSAT ground station software design and use of an expert system to analyze telemetry

    Science.gov (United States)

    Lawrence, Gregory W.

    1994-03-01

    The Petite Amateur Navy Satellite (PANSAT) is a communications satellite designed to be used by civilian amateur radio operators. A master ground station is being built at the Naval Postgraduate School. This computer system performs satellite commands, displays telemetry, trouble-shoots problems, and passes messages. The system also controls an open loop tracking antenna. This paper concentrates on the telemetry display, decoding, and interpretation through artificial intelligence (AI). The telemetry is displayed in an easily interpretable format, so that any user can understand the current health of the satellite and be cued as to any problems and possible solutions. Only the master ground station has the ability to receive all telemetry and send commands to the spacecraft; civilian ham users do not have access to this information. The telemetry data is decommutated and analyzed before it is displayed to the user, so that the raw data will not have to be interpreted by ground users. The analysis will use CLIPS imbedded in the code, and derive its inputs from telemetry decommutation. The program is an expert system using a forward chaining set of rules based on the expected operation and parameters of the satellite. By building the rules during the construction and design of the satellite, the telemetry can be well understood and interpreted after the satellite is launched and the designers may no longer be available to provide input to the problem.

  12. Can telemetry data obviate the need for sleep studies in Pierre Robin Sequence?

    Science.gov (United States)

    Aaronson, Nicole Leigh; Jabbour, Noel

    2017-09-01

    This study looks to correlate telemetry data gathered on patients with Pierre Robin Sequence (PRS) with sleep study data. Strong correlation might allow obstructive sleep apnea (OSA) to be reasonably predicted without the need for sleep study. Charts from forty-six infants with PRS who presented to our children's hospital between 2005 and 2015 and received a polysomnogram (PSG) prior to surgical intervention were retrospectively reviewed. Correlations and scatterplots were used to compare average daily oxygen nadir, overall oxygen nadir, and average number of daily desaturations from telemetry data with apnea-hypopnea index (AHI) and oxygen nadir on sleep study. Results were also categorized into groups of AHI ≥ or telemetry data and sleep study data. Patients with O2 nadir below 80% on telemetry were not more likely to have an O2 nadir below 80% on sleep study. Patients with an average O2 nadir below 80% did show some correlation with having an AHI greater than 10 on sleep study but this relationship did not reach significance. Of 22 patients who did not have any desaturations on telemetry below 80%, 16 (73%) had an AHI >10 on sleep study. In the workup of infants with PRS, the index of suspicion is high for OSA. In our series, telemetry data was not useful in ruling out severe OSA. Thus our data do not support forgoing sleep study in patients with PRS and concern for OSA despite normal telemetry patterns. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Research Update: Nanogenerators for self-powered autonomous wireless sensors

    Science.gov (United States)

    Khan, Usman; Hinchet, Ronan; Ryu, Hanjun; Kim, Sang-Woo

    2017-07-01

    Largely distributed networks of sensors based on the small electronics have great potential for health care, safety, and environmental monitoring. However, in order to have a maintenance free and sustainable operation, such wireless sensors have to be self-powered. Among various energies present in our environment, mechanical energy is widespread and can be harvested for powering the sensors. Piezoelectric and triboelectric nanogenerators (NGs) have been recently introduced for mechanical energy harvesting. Here we introduce the architecture and operational modes of self-powered autonomous wireless sensors. Thereafter, we review the piezoelectric and triboelectric NGs focusing on their working mechanism, structures, strategies, and materials.

  14. Time synchronization in ad-hoc wireless sensor networks

    Science.gov (United States)

    Sharma, Nishant

    2013-06-01

    Advances in micro-electronics and developments in the various technologies have given birth to this era of wireless sensor networks. A sensor network is the one which provides information about the surrounding environment by sensing it and clock synchronization in wireless sensor networks plays a vital role to maintain the integrity of entire network. In this paper two major low energy consumption clock synchronization algorithms, Reference Broadcast Synchronization (RBS) and Timing-Sync Protocol for Sensor Networks (TPSN) are simulated, which result in high level of accuracy, reliability, handles substantially greater node densities, supports mobility, and hence perform well under all possible conditions.

  15. Passive wireless sensing tags NASA inflatable structures.

    Energy Technology Data Exchange (ETDEWEB)

    Brocato, Robert Wesley

    2006-03-01

    This report gives a description of several types of wireless, unpowered remote sensors. Surface acoustic wave (SAW) devices were coupled with conventional sensors to create entirely new types of sensors. These sensors report physically measurable data in the same manner as the conventional sensors, but they do it remotely and without any local power source. The sensors are measured remotely using a radar-like interrogation device, and the sensors and their related communication electronics draw all of the power needed for communicating from the radar pulse. The report covers only a description of prototype sensors and not of the manufacturing requirements of these devices.

  16. Wireless Headset Communication System

    Science.gov (United States)

    Lau, Wilfred K.; Swanson, Richard; Christensen, Kurt K.

    1995-01-01

    System combines features of pagers, walkie-talkies, and cordless telephones. Wireless headset communication system uses digital modulation on spread spectrum to avoid interference among units. Consists of base station, 4 radio/antenna modules, and as many as 16 remote units with headsets. Base station serves as network controller, audio-mixing network, and interface to such outside services as computers, telephone networks, and other base stations. Developed for use at Kennedy Space Center, system also useful in industrial maintenance, emergency operations, construction, and airport operations. Also, digital capabilities exploited; by adding bar-code readers for use in taking inventories.

  17. Investigating wireless power transfer

    Science.gov (United States)

    St John, Stuart A.

    2017-09-01

    Understanding Physics is a great end in itself, but is also crucial to keep pace with developments in modern technology. Wireless power transfer, known to many only as a means to charge electric toothbrushes, will soon be commonplace in charging phones, electric cars and implanted medical devices. This article outlines how to produce and use a simple set of equipment to both demonstrate and investigate this phenomenon. It presents some initial findings and aims to encourage Physics educators and their students to conduct further research, pushing the bounds of their understanding.

  18. Dynamic wireless sensor networks

    CERN Document Server

    Oteafy, Sharief M A

    2014-01-01

    In this title, the authors leap into a novel paradigm of scalability and cost-effectiveness, on the basis of resource reuse. In a world with much abundance of wirelessly accessible devices, WSN deployments should capitalize on the resources already available in the region of deployment, and only augment it with the components required to meet new application requirements. However, if the required resources already exist in that region, WSN deployment converges to an assignment and scheduling scheme to accommodate for the new application given the existing resources. Such resources are polled

  19. Wired or Wireless Internet?

    DEFF Research Database (Denmark)

    Gimpel, Gregory

    2010-01-01

    This paper finds that network externalities play a minimal role in the choice of internet access technology. Potential adopters of mobile laptop internet view broadband technology as a black box, the technological details of which donot matter. The study uses qualitative techniques to explore how...... the speed of technological obsolescence, market share dominance, and the black boxing of technology influence consumer intention to adopt WiMax and 3G wireless internet for their laptop computers. The results, implications for industry, and areas for further research are discussed....

  20. Wireless installation standard

    International Nuclear Information System (INIS)

    Lim, Hwang Bin

    2007-12-01

    This is divided six parts which are radio regulation law on securing of radio resource, use of radio resource, protection of radio resource, radio regulation enforcement ordinance with securing, distribution and assignment of radio regulation, radio regulation enforcement regulation on utility of radio resource and technical qualification examination, a wireless installation regulation of technique standard and safety facility standard, radio regulation such as certification regulation of information communicative machines and regulation of radio station on compliance of signal security, radio equipment in radio station, standard frequency station and emergency communication.

  1. Unmanned Aerial Vehicle (UAV) Dynamic-Tracking Directional Wireless Antennas for Low Powered Applications that Require Reliable Extended Range Operations in Time Critical Scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Scott G. Bauer; Matthew O. Anderson; James R. Hanneman

    2005-10-01

    The proven value of DOD Unmanned Aerial Vehicles (UAVs) will ultimately transition to National and Homeland Security missions that require real-time aerial surveillance, situation awareness, force protection, and sensor placement. Public services first responders who routinely risk personal safety to assess and report a situation for emergency actions will likely be the first to benefit from these new unmanned technologies. ‘Packable’ or ‘Portable’ small class UAVs will be particularly useful to the first responder. They require the least amount of training, no fixed infrastructure, and are capable of being launched and recovered from the point of emergency. All UAVs require wireless communication technologies for real- time applications. Typically on a small UAV, a low bandwidth telemetry link is required for command and control (C2), and systems health monitoring. If the UAV is equipped with a real-time Electro-Optical or Infrared (EO/Ir) video camera payload, a dedicated high bandwidth analog/digital link is usually required for reliable high-resolution imagery. In most cases, both the wireless telemetry and real-time video links will be integrated into the UAV with unity gain omni-directional antennas. With limited on-board power and payload capacity, a small UAV will be limited with the amount of radio-frequency (RF) energy it transmits to the users. Therefore, ‘packable’ and ‘portable’ UAVs will have limited useful operational ranges for first responders. This paper will discuss the limitations of small UAV wireless communications. The discussion will present an approach of utilizing a dynamic ground based real-time tracking high gain directional antenna to provide extend range stand-off operation, potential RF channel reuse, and assured telemetry and data communications from low-powered UAV deployed wireless assets.

  2. Wireless network security theories and applications

    CERN Document Server

    Chen, Lei; Zhang, Zihong

    2013-01-01

    Wireless Network Security Theories and Applications discusses the relevant security technologies, vulnerabilities, and potential threats, and introduces the corresponding security standards and protocols, as well as provides solutions to security concerns. Authors of each chapter in this book, mostly top researchers in relevant research fields in the U.S. and China, presented their research findings and results about the security of the following types of wireless networks: Wireless Cellular Networks, Wireless Local Area Networks (WLANs), Wireless Metropolitan Area Networks (WMANs), Bluetooth

  3. Household wireless electroencephalogram hat

    Science.gov (United States)

    Szu, Harold; Hsu, Charles; Moon, Gyu; Yamakawa, Takeshi; Tran, Binh

    2012-06-01

    We applied Compressive Sensing to design an affordable, convenient Brain Machine Interface (BMI) measuring the high spatial density, and real-time process of Electroencephalogram (EEG) brainwaves by a Smartphone. It is useful for therapeutic and mental health monitoring, learning disability biofeedback, handicap interfaces, and war gaming. Its spec is adequate for a biomedical laboratory, without the cables hanging over the head and tethered to a fixed computer terminal. Our improved the intrinsic signal to noise ratio (SNR) by using the non-uniform placement of the measuring electrodes to create the proximity of measurement to the source effect. We computing a spatiotemporal average the larger magnitude of EEG data centers in 0.3 second taking on tethered laboratory data, using fuzzy logic, and computing the inside brainwave sources, by Independent Component Analysis (ICA). Consequently, we can overlay them together by non-uniform electrode distribution enhancing the signal noise ratio and therefore the degree of sparseness by threshold. We overcame the conflicting requirements between a high spatial electrode density and precise temporal resolution (beyond Event Related Potential (ERP) P300 brainwave at 0.3 sec), and Smartphone wireless bottleneck of spatiotemporal throughput rate. Our main contribution in this paper is the quality and the speed of iterative compressed image recovery algorithm based on a Block Sparse Code (Baranuick et al, IEEE/IT 2008). As a result, we achieved real-time wireless dynamic measurement of EEG brainwaves, matching well with traditionally tethered high density EEG.

  4. Biomonitoring with Wireless Communications

    Energy Technology Data Exchange (ETDEWEB)

    Budinger, Thomas F.

    2003-03-01

    This review is divided into three sections: technologies for monitoring physiological parameters; biosensors for chemical assays and wireless communications technologies including image transmissions. Applications range from monitoring high risk patients for heart, respiratory activity and falls to sensing levels of physical activity in military, rescue, and sports personnel. The range of measurements include, heart rate, pulse wave form, respiratory rate, blood oxygen, tissue pCO2, exhaled carbon dioxide and physical activity. Other feasible measurements will employ miniature chemical laboratories on silicon or plastic chips. The measurements can be extended to clinical chemical assays ranging from common blood assays to protein or specialized protein measurements (e.g., troponin, creatine, and cytokines such as TNF and IL6). Though the feasibility of using wireless technology to communicate vital signs has been demonstrated 32 years ago (1) it has been only recently that practical and portable devices and communications net works have become generally available for inexpensive deployment of comfortable and affordable devices and systems.

  5. A Reconfigurable Transmitter and Receiver for Aeronautical Telemetry Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This project focuses on the development of a reconfigurable microwave transmitter and receiver for telemetry applications. Both the transmitter and receiver are able...

  6. Alaska northern fur seal adult male satellite telemetry data, 2009-2010

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set is comprised of satellite-linked telemetry data collected to investigate winter migration patterns and foraging strategies of adult male northern fur...

  7. Alaska Steller Sea Lion Habitat Model Satellite Telemetry and Environmental Data, 2000-2012

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The at-sea habitat use of Steller sea lions was modeled from location and dive behavior data obtained from the deployment of satellite-linked telemetry tags on sea...

  8. Ocean Surface Topography Mission (OSTM) /Jason-2: Telemetry (NODC Accession 0044986)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This accession contains the data descriptions for the OSTM/Jason-2 Telemetry data, which is served through the NOAA/NESDIS Comprehensive Large Array-data Stewardship...

  9. Attitude Model of a Reaction Wheel/Fixed Thruster Based Satellite Using Telemetry Data

    National Research Council Canada - National Science Library

    Smith, Jason E

    2005-01-01

    .... While there are a multitude of ways to determine a satellite's orientation, very little research has been done on determining if the attitude of a satellite can be determined directly from telemetry...

  10. Flight Demonstration Results of an Inertial Measurement Unit and Global Positioning System Translator Telemetry System

    National Research Council Canada - National Science Library

    David, Bradford

    2001-01-01

    .... A GPS translator from the Johns Hopkins University Applied Physics Laboratory and a low-cost IMU designed by ARL from commercial off-the-shelf components were combined with a telemetry system, packaged...

  11. Satellite telemetry: A new tool for wildlife research and management

    Science.gov (United States)

    Fancy, Steven G.; Pank, Larry F.; Douglas, David C.; Curby, Catherine H.; Garner, Gerald W.; Amstrup, Steven C.; Regelin, Wayne L.

    1998-01-01

    The U.S. Fish and Wildlife Service and the Alaska Department of Fish and Game have cooperated since 1984 to develop and evaluate satellite telemetry as a means of overcoming the high costs and logistical problems of conventional VHF (very high frequency) radiotelemetry systems. Detailed locational and behavioral data on caribou (Rangifer tarandus), polar bears (Ursus maritimus), and other large mammals in Alaska have been obtained using the Argos Data Collection and Location System (DCLS). The Argos system, a cooperative project of the Centre National d'Études Spatiales of France, the National Oceanic and Atmospheric Administration, and the National Aeronautics and Space Administration, is designed to acquire environmental data on a routine basis from anywhere on earth. Transmitters weighing 1.6-2.0 kg and functioning approximately 12-18 months operated on a frequency of 401.650 MHz. Signals from the transmitters were received by Argos DCLS instruments aboard two Tiros-N weather satellites in sun-synchronous, nearpolar orbits. Data from the satellites were received at tracking stations, transferred to processing centers in Maryland and France, and made available to users via computer tape, printouts, or telephone links.During 1985 and 1986, more than 25,000 locations and an additional 28,000 sets of sensor data (transmitter temperature and short-term and long-term indices of animal activity) were acquired for caribou and polar bears. Locations were calculated from the Doppler shift in the transmitted signal as the satellite approached and then moved away from the transmitter. The mean locational error for transmitters at known locations (n - 1,265) was 829 m; 90% of the calculated locations were within 1,700 m of the true location. Caribou transmitters provided a mean of 3.1 (+5.0. SD) locations per day during 6h of daily operation, and polar bear transmitters provided 1.7 (+6.9SD) locations during 12h of operation every third day. During the first 6 months of

  12. Structural processing for wireless communications

    CERN Document Server

    Lu, Jianhua; Ge, Ning

    2015-01-01

    This brief presents an alternative viewpoint on processing technology for wireless communications based on recent research advances. As a lever in emerging processing technology, the structure perspective addresses the complexity and uncertainty issues found in current wireless applications. Likewise, this brief aims at providing a new prospective to the development of communication technology and information science, while stimulating new theories and technologies for wireless systems with ever-increasing complexity. Readers of this brief may range from graduate students to researchers in related fields.

  13. Radio Relays Improve Wireless Products

    Science.gov (United States)

    2009-01-01

    Signal Hill, California-based XCOM Wireless Inc. developed radio frequency micromachine (RF MEMS) relays with a Phase II Small Business Innovation Research (SBIR) contract through NASA?s Jet Propulsion Laboratory. In order to improve satellite communication systems, XCOM produced wireless RF MEMS relays and tunable capacitors that use metal-to-metal contact and have the potential to outperform most semiconductor technologies while using less power. These relays are used in high-frequency test equipment and instrumentation, where increased speed can mean significant cost savings. Applications now also include mainstream wireless applications and greatly improved tactical radios.

  14. Wireless Communications in Smart Grid

    Science.gov (United States)

    Bojkovic, Zoran; Bakmaz, Bojan

    Communication networks play a crucial role in smart grid, as the intelligence of this complex system is built based on information exchange across the power grid. Wireless communications and networking are among the most economical ways to build the essential part of the scalable communication infrastructure for smart grid. In particular, wireless networks will be deployed widely in the smart grid for automatic meter reading, remote system and customer site monitoring, as well as equipment fault diagnosing. With an increasing interest from both the academic and industrial communities, this chapter systematically investigates recent advances in wireless communication technology for the smart grid.

  15. Wireless home networking for dummies

    CERN Document Server

    Briere, Danny; Ferris, Edward

    2010-01-01

    The perennial bestseller shows you how share your files and Internet connection across a wireless network. Fully updated for Windows 7 and Mac OS X Snow Leopard, this new edition of this bestseller returns with all the latest in wireless standards and security. This fun and friendly guide shows you how to integrate your iPhone, iPod touch, smartphone, or gaming system into your home network. Veteran authors escort you through the various financial and logisitical considerations that you need to take into account before building a wireless network at home.: Covers the basics of planning, instal

  16. Microwave materials for wireless applications

    CERN Document Server

    Cruickshank, David B

    2011-01-01

    This practical resource offers you an in-depth, up-to-date understanding of the use of microwave magnetic materials for cutting-edge wireless applications. The book discusses device applications used in wireless infrastructure base stations, point-to-point radio links, and a range of more specialized microwave systems. You find detailed discussions on the attributes of each family of magnetic materials with respect to specific wireless applications. Moreover, the book addresses two of the hottest topics in the field today - insertion loss and intermodulation. This comprehensive reference also

  17. Cochlear Implant Impedance Telemetry Measurements and Model Calculations to Estimate Modiolar Currents

    OpenAIRE

    von Rohr, R

    2011-01-01

    The use of impedance and neural response telemetry measurements through stimulation and recording of electrical signals can facilitate device fitting and parameter adjustments, especially in young children. However, the detailed configuration of electrical impedances and current distributions around the electrode array is unknown and has not been able to be determined using standard impedance telemetry measures. We therefore attempted to improve the impedance measurement procedure by apply...

  18. The integrated satellite-acoustic telemetry (iSAT) system for tracking marine megafauna

    KAUST Repository

    De la Torre, Pedro

    2012-10-06

    This document describes the integrated satellite-acoustic telemetry (iSAT) system: an autonomous modular system for tracking the movements of large pelagic fish using acoustic telemetry and satellite communications. The sensor platform is described along with the propulsion and navigation systems. An application for tracking the whale shark (Rhincodon typus) in the Red Sea is included along with a discussion of the technical difficulties that such a system faces.

  19. Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture

    Science.gov (United States)

    McCown, Steven H [Rigby, ID; Derr, Kurt W [Idaho Falls, ID; Rohde, Kenneth W [Idaho Falls, ID

    2012-05-08

    Wireless device monitoring methods, wireless device monitoring systems, and articles of manufacture are described. According to one embodiment, a wireless device monitoring method includes accessing device configuration information of a wireless device present at a secure area, wherein the device configuration information comprises information regarding a configuration of the wireless device, accessing stored information corresponding to the wireless device, wherein the stored information comprises information regarding the configuration of the wireless device, comparing the device configuration information with the stored information, and indicating the wireless device as one of authorized and unauthorized for presence at the secure area using the comparing.

  20. Measurements on wireless transmission of ECG signals

    Science.gov (United States)

    Gabrielli, A.; Lax, I.

    2016-12-01

    The scope of this research is to design an electronic prototype, an operative system as a proof of concept, to transmit and receive biological parameters, in particular electrocardiogram signals, through dedicated wireless circuits. The apparatus features microelectronics chips that were developed for more general biomedical applications, here adapted to deal with cardiac signals. The paper mainly focuses on the electronic aspects, as in this study we do not face medical or clinical aspects of the system. The transmitter circuit uses a commercial instrumentation amplifier and the receiver has been equipped with wide-band amplifiers along with made-in-the-lab band-pass filters centered at the carrier. We have been able to mount the entire system prototype into a preliminary data acquisition chain that reads out the electrocardiogram signal. The prototype allows acquiring the waveform, converting it to a digital pattern and open the transmission through a series of high-frequency packets exploiting the Ultra Wide Band protocol. The sensor value is embedded in the transmission through the rate of the digital packets. In fact, these are sent wireless at a specific packet-frequency that depends on the sensor amplitude and are detected into a receiver circuit that recovers the information.

  1. Animal movement constraints improve resource selection inference in the presence of telemetry error.

    Science.gov (United States)

    Brost, Brian M; Hooten, Mevin B; Hanks, Ephraim M; Small, Robert J

    2015-10-01

    Multiple factors complicate the analysis of animal telemetry location data. Recent advancements address issues such as temporal autocorrelation and telemetry measurement error, but additional challenges remain. Difficulties introduced by complicated error structures or barriers to animal movement can weaken inference. We propose an approach for obtaining resource selection inference from animal location data that accounts for complicated error structures, movement constraints, and temporally autocorrelated observations. We specify a model for telemetry data observed with error conditional on unobserved true locations that reflects prior knowledge about constraints in the animal movement process. The observed telemetry data are modeled using a flexible distribution that accommodates extreme errors and complicated error structures. Although constraints to movement are often viewed as a nuisance, we use constraints to simultaneously estimate and account for telemetry error. We apply the model to simulated data, showing that it outperforms common ad hoc approaches used when confronted with measurement error and movement constraints. We then apply our framework to an Argos satellite telemetry data set on harbor seals (Phoca vitulina) in the Gulf of Alaska, a species that is constrained to move within the marine environment and adjacent coastlines.

  2. The safety of UK video telemetry units: results of a national service evaluation.

    Science.gov (United States)

    Kandler, Rosalind; Lai, Ming; Ponnusamy, Athi; Bland, Jeremy; Pang, Catherine

    2013-12-01

    To assess patient safety during seizures occurring on UK video telemetry units and identify factors in unit infrastructure which may improve safety with the intention of producing national guidelines. A prospective multicentre national service evaluation of the occurrence of adverse events and level of nurse attendance during seizures occurring on video telemetry units was performed. Data from 272 seizures from 27 video telemetry units across the UK were analysed. Adverse events occurred in 12% of seizures: 7% were physical events such as falls or respiratory compromise and 5% were unnoticed seizures. Nursing staff did not attend the patients in 44% of seizures and attendance was delayed beyond 30s in a further 29%. Only 27% of seizures were attended by a Healthcare Professional within half a minute. The most important factor shown to improve timely attendance of patients during seizures was the presence of a nurse dedicated to the telemetry bed(s). The site of the telemetry bed (bay or cubicle) and method of observation (direct or indirect) was less important. An optimal nurse-to-patient ratio was difficult to identify but the study suggests that a ratio of at least 1 nurse to 4 patients is appropriate. The results provide an evidence base for the production of national standards and guidelines for surveillance of patients during video telemetry to improve patient safety. Copyright © 2013 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  3. Toward a national animal telemetry network for aquatic observations in the United States

    Science.gov (United States)

    Block, Barbara A.; Holbrook, Christopher; Simmons, Samantha E; Holland, Kim N; Ault, Jerald S.; Costa, Daniel P.; Mate, Bruce R; Seitz, Andrew C.; Arendt, Michael D.; Payne, John; Mahmoudi, Behzad; Moore, Peter L.; Price, James; J. J. Levenson,; Wilson, Doug; Kochevar, Randall E

    2016-01-01

    Animal telemetry is the science of elucidating the movements and behavior of animals in relation to their environment or habitat. Here, we focus on telemetry of aquatic species (marine mammals, sharks, fish, sea birds and turtles) and so are concerned with animal movements and behavior as they move through and above the world’s oceans, coastal rivers, estuaries and great lakes. Animal telemetry devices (“tags”) yield detailed data regarding animal responses to the coupled ocean–atmosphere and physical environment through which they are moving. Animal telemetry has matured and we describe a developing US Animal Telemetry Network (ATN) observing system that monitors aquatic life on a range of temporal and spatial scales that will yield both short- and long-term benefits, fill oceanographic observing and knowledge gaps and advance many of the U.S. National Ocean Policy Priority Objectives. ATN has the potential to create a huge impact for the ocean observing activities undertaken by the U.S. Integrated Ocean Observing System (IOOS) and become a model for establishing additional national-level telemetry networks worldwide.

  4. Animal movement constraints improve resource selection inference in the presence of telemetry error

    Science.gov (United States)

    Brost, Brian M.; Hooten, Mevin B.; Hanks, Ephraim M.; Small, Robert J.

    2016-01-01

    Multiple factors complicate the analysis of animal telemetry location data. Recent advancements address issues such as temporal autocorrelation and telemetry measurement error, but additional challenges remain. Difficulties introduced by complicated error structures or barriers to animal movement can weaken inference. We propose an approach for obtaining resource selection inference from animal location data that accounts for complicated error structures, movement constraints, and temporally autocorrelated observations. We specify a model for telemetry data observed with error conditional on unobserved true locations that reflects prior knowledge about constraints in the animal movement process. The observed telemetry data are modeled using a flexible distribution that accommodates extreme errors and complicated error structures. Although constraints to movement are often viewed as a nuisance, we use constraints to simultaneously estimate and account for telemetry error. We apply the model to simulated data, showing that it outperforms common ad hoc approaches used when confronted with measurement error and movement constraints. We then apply our framework to an Argos satellite telemetry data set on harbor seals (Phoca vitulina) in the Gulf of Alaska, a species that is constrained to move within the marine environment and adjacent coastlines.

  5. An Approach to Integrated Spectrum Efficient Network Enhanced Telemetry (iSENET))

    Science.gov (United States)

    Okino, Clayton; Gao, Jay; Clare, Loren; Darden, Scott; Walsh, William; Loh, Kok-kiong

    2006-01-01

    As the integrated Network Enhanced Telemetry (iNET) program moves forward in resolving systems engineering design and architecture definition, critical technology "gaps" and a migration path to realizing the integration of this technology are needed to insure a smooth transition from the current legacy point to point telemetry links to a network oriented telemetry system. Specifically, identified by the DoD aeronautical telemetry community is the need for a migration to a network solution for command, control, and transfer of test data by optimizing the physical, data link, and network layers. In this paper, we present a network-centric telemetry approach based on variants of 802.11 that leverages the open standards as well as the previous Advanced Range Telemetry (ARTM) work on the physical layer waveform. Specifically, we present a burst modem approach based on the recent AOFDM 802.11a work, a TDMA-like MAC layer approach based on 802.11e, and then add additional MAC layer features to allow for the multi-hop aeronautical environment using a variant of the current working standards of 802.11s. The combined benefits of the variants obtained from 802.11a, 802.11e, and 802.11s address the needs for both spectrum efficiency in the aeronautical environment and the iNET program.

  6. Juvenile Salmon Acoustic Telemetry System Transmitter Downsize Assessment

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Thomas J.; Myjak, Mitchell J.

    2010-04-30

    At the request of the U.S. Army Corps of Engineers, Portland District, researchers from Pacific Northwest National Laboratory investigated the use of an application-specific integrated circuit (ASIC) to reduce the weight and volume of Juvenile Salmon Acoustic Telemetry System (JSATS) transmitters while retaining current functionality. Review of the design of current JSATS transmitters identified components that could be replaced by an ASIC while retaining the function of the current transmitter and offering opportunities to extend function if desired. ASIC design alternatives were identified that could meet transmitter weight and volume targets of 200 mg and 100 mm3. If alternatives to the cylindrical batteries used in current JSATS transmitters can be identified, it could be possible to implant ASIC-based JSATS transmitters by injection rather than surgery. Using criteria for the size of fish suitable for surgical implantation of current JSATS transmitters, it was concluded that fish as small as 70 mm in length could be implanted with an ASIC-based transmitter, particularly if implantation by injection became feasible.

  7. A fast and accurate decoder for underwater acoustic telemetry.

    Science.gov (United States)

    Ingraham, J M; Deng, Z D; Li, X; Fu, T; McMichael, G A; Trumbo, B A

    2014-07-01

    The Juvenile Salmon Acoustic Telemetry System, developed by the U.S. Army Corps of Engineers, Portland District, has been used to monitor the survival of juvenile salmonids passing through hydroelectric facilities in the Federal Columbia River Power System. Cabled hydrophone arrays deployed at dams receive coded transmissions sent from acoustic transmitters implanted in fish. The signals' time of arrival on different hydrophones is used to track fish in 3D. In this article, a new algorithm that decodes the received transmissions is described and the results are compared to results for the previous decoding algorithm. In a laboratory environment, the new decoder was able to decode signals with lower signal strength than the previous decoder, effectively increasing decoding efficiency and range. In field testing, the new algorithm decoded significantly more signals than the previous decoder and three-dimensional tracking experiments showed that the new decoder's time-of-arrival estimates were accurate. At multiple distances from hydrophones, the new algorithm tracked more points more accurately than the previous decoder. The new algorithm was also more than 10 times faster, which is critical for real-time applications on an embedded system.

  8. Intrauterine Telemetry to Measure Mouse Contractile Pressure In Vivo

    Science.gov (United States)

    Rada, Cara C.; Pierce, Stephanie L.; Grotegut, Chad A.; England, Sarah K.

    2015-01-01

    A complex integration of molecular and electrical signals is needed to transform a quiescent uterus into a contractile organ at the end of pregnancy. Despite the discovery of key regulators of uterine contractility, this process is still not fully understood. Transgenic mice provide an ideal model in which to study parturition. Previously, the only method to study uterine contractility in the mouse was ex vivo isometric tension recordings, which are suboptimal for several reasons. The uterus must be removed from its physiological environment, a limited time course of investigation is possible, and the mice must be sacrificed. The recent development of radiometric telemetry has allowed for longitudinal, real-time measurements of in vivo intrauterine pressure in mice. Here, the implantation of an intrauterine telemeter to measure pressure changes in the mouse uterus from mid-pregnancy until delivery is described. By comparing differences in pressures between wild type and transgenic mice, the physiological impact of a gene of interest can be elucidated. This technique should expedite the development of therapeutics used to treat myometrial disorders during pregnancy, including preterm labor. PMID:25867820

  9. Rat cardiovascular telemetry: Marginal distribution applied to positive control drugs.

    Science.gov (United States)

    Accardi, M V; Troncy, E; Abtout, S; Ascah, A; Maghezzi, S; Authier, S

    2016-01-01

    Cardiovascular effects are considered frequent during drug safety testing. This investigation aimed to characterize the pharmacological response of the conscious telemetered rat in vivo model to known cardiovascular active agents. These effects were analyzed using statistical analysis and cloud representation with marginal distribution curves for the contractility index and heart rate as to assess the effect relationship between cardiac variables. Arterial blood pressure, left ventricular pressure, electrocardiogram and body temperature were monitored. The application of data cloud with marginal distribution curves to heart rate and contractility index provided an interesting tactic during the interpretation of drug-induced changes particularly during selective time resolution (i.e. marginal distribution curves restricted to Tmax). Taken together, the present data suggests that marginal distribution curves can be a valuable interpretation strategy when using the rat cardiovascular telemetry model to detect drug-induced cardiovascular effects. Marginal distribution curves could also be considered during the interpretation of other inter-dependent parameters in safety pharmacology studies. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  10. Telemetry System Utilization for Stress Monitoring of Pilots During Training

    Directory of Open Access Journals (Sweden)

    Luboš Socha

    2016-10-01

    Full Text Available Air transport development brings an increased focus on the safety of piloting. The safety conditions can be assessed by mental workload. Psychic discomfort or excessive stress on pilots can negatively influence the course of flights. Therefore it appears convenient to monitor such parameters, which represent the mental wellbeing, or discomfort of a pilot. Since physiological measurements can provide a good information about mental workload or stress, this work primarily focuses on the observation of the change in heart rate, as it is an indicator of stress during the training of pilots, using the designed modular telemetry system. Another aim of this study is to evaluate the influence of a change in the avionic data visualization. This can have an unfavorable effect on the piloting of an airplane. This work, based on the evaluation of heart rate shows, that the switch from analog visualization to glass cockpit creates increased levels of stress in pilots, which was proved for all examined subjects except one. Significant level of correlation in the heart beat rate change in subjects in the course of training was also discovered.

  11. Real-time monitoring of seismic data using satellite telemetry

    Directory of Open Access Journals (Sweden)

    L. Merucci

    1997-06-01

    Full Text Available This article describes the ARGO Satellite Seismic Network (ARGO SSN as a reliable system for monitoring, collection, visualisation and analysis of seismic and geophysical low-frequency data, The satellite digital telemetry system is composed of peripheral geophysical stations, a centraI communications node (master sta- tion located in CentraI Italy, and a data collection and processing centre located at ING (Istituto Nazionale di Geofisica, Rome. The task of the peripheral stations is to digitalise and send via satellite the geophysical data collected by the various sensors to the master station. The master station receives the data and forwards them via satellite to the ING in Rome; it also performs alI the monitoring functions of satellite communications. At the data collection and processing centre of ING, the data are received and analysed in real time, the seismic events are identified and recorded, the low-frequency geophysical data are stored. In addition, the generaI sta- tus of the satellite network and of each peripheral station connected, is monitored. The procedure for analysjs of acquired seismic signals allows the automatic calculation of local magnitude and duration magnitude The communication and data exchange between the seismic networks of Greece, Spain and Italy is the fruit of a recent development in the field of technology of satellite transmission of ARGO SSN (project of European Community "Southern Europe Network for Analysis of Seismic Data"

  12. Implantation of a refillable glucose monitoring-telemetry device.

    Science.gov (United States)

    Atanasov, P; Yang, S; Salehi, C; Ghindilis, A L; Wilkins, E; Schade, D

    1997-01-01

    This study describes the components and short-term in vivo evaluation of an integrated implantable system consisting of an amperometric glucose biosensor, a miniature potentiostat, a FM signal transmitter, and a power supply. The device (dimensions: 5.0 x 7.0 x 1.5 cm) was implanted subcutaneously in healthy mongrel dogs. The biosensor performance was evaluated in vitro prior to implantation using standard solutions simulating the physiological environment. A linear response to glucose concentration was observed throughout the physiological and pathophysiological range (with an upper limit of 25 mM glucose, and a sensitivity of 0.5 microA/mM). The results of short-term subcutaneous implantation of the integrated system demonstrated good agreement between the glucose concentration measured by the biosensor and that obtained using standard glucose determination methods. The delay-time between the tissue glucose level (measured by the biosensor) and the blood glucose level (obtained by standard methodology) was 3-7 min. These results demonstrated the feasibility of data transmission by a telemetry system through the skin of a dog and allowed the commencement of chronic in vivo testing. During the chronic implantation the biosensor was refilled in vivo. A rejuvenation of the sensor's response after refilling was observed suggesting the potential of such sensors for long-term implantation.

  13. Bluetooth: The invisible connector. Short-range wireless technology for the contemporary orthodontic practice.

    Science.gov (United States)

    Mupparapu, Muralidhar

    2007-06-01

    Although it sounds like a nonvital tooth, Bluetooth is actually one of technology's hottest trends. It is an industrial specification for wireless personal area networks, but for a busy orthodontic practice, it translates to freedom from cables and cords. Despite its enigmatic name, Bluetooth-based devices and the wireless technology that these gadgets work with are here to stay. They promise to make life easier for the electronic-device users of all stripes, and orthodontists are no exception. The purpose of this article is to orient orthodontists, office staff, and auxiliary personnel to this universal wireless technology that is slowly becoming an integral part of every office.

  14. Legal and Technical Implications of Collecting Wireless Data as an Evidence Source

    Science.gov (United States)

    Turnbull, Benjamin; Osborne, Grant; Simon, Matthew

    The collection of digital devices for forensic analysis is an area that requires constant revision. New technologies and connectivity options change what devices are able to hold electronic evidence and also the methods needed to secure it. This work focuses on the development of an 802.11-based wireless networking (Wi-Fi) forensic analysis tool that can aid in the identification and collection of evidence by identifying the presence of wireless networks and the devices to which they are attached. Specifically, this paper seeks to discuss the potential legal and technical challenges faced in the development of a wireless forensic tool.

  15. Advanced Wireless Integrated Navy Network

    National Research Council Canada - National Science Library

    Stutzman, Warren; Habayeb, Rick

    2005-01-01

    Quarterly progress report No. I on AWINN hardware and software configurations of smart, wideband, multi-function antennas, secure configurable platform, close-in command and control for Sea Basing visualization of wireless...

  16. Wireless Damage Location Sensing System

    Science.gov (United States)

    Woodard, Stanley E. (Inventor); Taylor, Bryant Douglas (Inventor)

    2012-01-01

    A wireless damage location sensing system uses a geometric-patterned wireless sensor that resonates in the presence of a time-varying magnetic field to generate a harmonic response that will experience a change when the sensor experiences a change in its geometric pattern. The sensing system also includes a magnetic field response recorder for wirelessly transmitting the time-varying magnetic field and for wirelessly detecting the harmonic response. The sensing system compares the actual harmonic response to a plurality of predetermined harmonic responses. Each predetermined harmonic response is associated with a severing of the sensor at a corresponding known location thereof so that a match between the actual harmonic response and one of the predetermined harmonic responses defines the known location of the severing that is associated therewith.

  17. Introduction to wireless sensor networks

    CERN Document Server

    Forster, Anna

    2016-01-01

    Explores real-world wireless sensor network development, deployment, and applications. The book begins with an introduction to wireless sensor networks and their fundamental concepts. Hardware components, operating systems, protocols, and algorithms that make up the anatomy of a sensor node are described in chapter two. Properties of wireless communications, medium access protocols, wireless links, and link estimation protocols are described in chapter three and chapter four. Routing basics and metrics, clustering techniques, time synchronization and localization protocols, as well as sensing techniques are introduced in chapter five to nine. The concluding chapter summarizes the learnt methods and shows how to use them to deploy real-world sensor networks in a structured way.

  18. Wireless cortical implantable systems

    CERN Document Server

    Majidzadeh Bafar, Vahid

    2013-01-01

    Wireless Cortical Implantable Systems examines the design for data acquisition and transmission in cortical implants. The first part of the book covers existing system-level cortical implants, as well as future devices. The authors discuss the major constraints in terms of microelectronic integration. The second part of the book focuses on system-level as well as circuit and system level solutions to the development of ultra low-power and low-noise microelectronics for cortical implants. Existing solutions are presented and novel methods and solutions proposed. The third part of the book focuses on the usage of digital impulse radio ultra wide-band transmission as an efficient method to transmit cortically neural recorded data at high data-rate to the outside world. Original architectural and circuit and system solutions are discussed.

  19. Wireless Ad Hoc Networks

    Directory of Open Access Journals (Sweden)

    Hong-Chuan Yang

    2007-01-01

    Full Text Available We study the energy-efficient configuration of multihop paths with automatic repeat request (ARQ mechanism in wireless ad hoc networks. We adopt a cross-layer design approach and take both the quality of each radio hop and the battery capacity of each transmitting node into consideration. Under certain constraints on the maximum tolerable transmission delay and the required packet delivery ratio, we solve optimization problems to jointly schedule the transmitting power of each transmitting node and the retransmission limit over each hop. Numerical results demonstrate that the path configuration methods can either significantly reduce the average energy consumption per packet delivery or considerably extend the average lifetime of the multihop route.

  20. Wireless Josephson amplifier

    International Nuclear Information System (INIS)

    Narla, A.; Sliwa, K. M.; Hatridge, M.; Shankar, S.; Frunzio, L.; Schoelkopf, R. J.; Devoret, M. H.

    2014-01-01

    Josephson junction parametric amplifiers are playing a crucial role in the readout chain in superconducting quantum information experiments. However, their integration with current 3D cavity implementations poses the problem of transitioning between waveguide, coax cables, and planar circuits. Moreover, Josephson amplifiers require auxiliary microwave components, like directional couplers and/or hybrids, that are sources of spurious losses and impedance mismatches that limit measurement efficiency and amplifier tunability. We have developed a wireless architecture for these parametric amplifiers that eliminates superfluous microwave components and interconnects. This greatly simplifies their assembly and integration into experiments. We present an experimental realization of such a device operating in the 9–11 GHz band with about 100 MHz of amplitude gain-bandwidth product, on par with devices mounted in conventional sample holders. The simpler impedance environment presented to the amplifier also results in increased amplifier tunability.

  1. Secure positioning in wireless networks

    DEFF Research Database (Denmark)

    Capkun, Srdjan; Hubaux, Jean-Pierre

    2006-01-01

    So far, the problem of positioning in wireless networks has been studied mainly in a non-adversarial settings. In this work, we analyze the resistance of positioning techniques to position and distance spoofing attacks. We propose a mechanism for secure positioning of wireless devices, that we call...... Verifiable Multilateration. We then show how this mechanism can be used to secure positioning in sensor networks. We analyze our system through simulations....

  2. Wireless Communications in Reverberant Environments

    Science.gov (United States)

    2015-01-01

    solutions exist which can be tailored to meet the needs nearly any wireless application. Some notable current solutions include USRPs [27] and GNURadio ...tailored to meet the needs nearly any wireless application. Some notable current solutions include USRPs [27] and GNURadio [28]. For this effort, the WARPv3...en.wikipedia.org/wiki/List of software-defined radios [27] “Ettus research.” [Online]. Available: http://www.ettus.com [28] “ Gnuradio .” [Online]. Available: http

  3. WIRELESS MINE WIDE TELECOMMUNICATIONS TECHNOLOGY

    Energy Technology Data Exchange (ETDEWEB)

    Zvi H. Meiksin

    2002-04-01

    Two industrial prototype units for through-the-earth wireless communication were constructed and tested. Preparation for a temporary installation in NIOSH's Lake Lynn mine for the through-the-earth and the in-mine system were completed. Progress was made in the programming of the in-mine system to provide data communication. Work has begun to implement a wireless interface between equipment controllers and our in-mine system.

  4. WIRELESS MINE WIDE TELECOMMUNICATIONS TECHNOLOGY

    International Nuclear Information System (INIS)

    Zvi H. Meiksin

    2002-01-01

    Two industrial prototype units for through-the-earth wireless communication were constructed and tested. Preparation for a temporary installation in NIOSH's Lake Lynn mine for the through-the-earth and the in-mine system were completed. Progress was made in the programming of the in-mine system to provide data communication. Work has begun to implement a wireless interface between equipment controllers and our in-mine system

  5. Reliable intraocular pressure measurement using automated radio-wave telemetry

    Directory of Open Access Journals (Sweden)

    Paschalis EI

    2014-01-01

    Full Text Available Eleftherios I Paschalis,* Fabiano Cade,* Samir Melki, Louis R Pasquale, Claes H Dohlman, Joseph B CiolinoMassachusetts Eye and Ear Infirmary, Harvard Medical School, Boston, MA, USA*These authors contributed equally to this workPurpose: To present an autonomous intraocular pressure (IOP measurement technique using a wireless implantable transducer (WIT and a motion sensor.Methods: The WIT optical aid was implanted within the ciliary sulcus of a normotensive rabbit eye after extracapsular clear lens extraction. An autonomous wireless data system (AWDS comprising of a WIT and an external antenna aided by a motion sensor provided continuous IOP readings. The sensitivity of the technique was determined by the ability to detect IOP changes resulting from the administration of latanoprost 0.005% or dorzolamide 2%, while the reliability was determined by the agreement between baseline and vehicle (saline IOP.Results: On average, 12 diurnal and 205 nocturnal IOP measurements were performed with latanoprost, and 26 diurnal and 205 nocturnal measurements with dorzolamide. No difference was found between mean baseline IOP (13.08±2.2 mmHg and mean vehicle IOP (13.27±2.1 mmHg (P=0.45, suggesting good measurement reliability. Both antiglaucoma medications caused significant IOP reduction compared to baseline; latanoprost reduced mean IOP by 10% (1.3±3.54 mmHg; P<0.001, and dorzolamide by 5% (0.62±2.22 mmHg; P<0.001. Use of latanoprost resulted in an overall twofold higher IOP reduction compared to dorzolamide (P<0.001. Repeatability was ±1.8 mmHg, assessed by the variability of consecutive IOP measurements performed in a short period of time (≤1 minute, during which the IOP is not expected to change.Conclusion: IOP measurements in conscious rabbits obtained without the need for human interactions using the AWDS are feasible and provide reproducible results.Keywords: IOP, pressure transducer, wireless, MEMS, implant, intraocular

  6. A Bi-directional Energy Splitable Model for Energy Optimization in Wireless Sensor Networks

    OpenAIRE

    Rajeswari, A; Kalaivaani, P.T

    2011-01-01

    Wireless Sensor Networks is a budding  prototype of networking and computing, where a node may be self powered and individual node have the capability to sense and compute and communicate. Wireless Sensor Networks have been proposed for variety of applications such as Industrial control and monitoring and home automation and consumer electronics and security andMilitary sensing, Asset tracking and supply chain management, Intelligent Agriculture, Missile directing, Fire alarming, Landslide Wa...

  7. Design and performance of radio telemetry systems for assessing juvenile fish passage at three hydroelectric dams: Chapter 6.5

    Science.gov (United States)

    Beeman, John W.; Hockersmith, Eric; Stevenson, John R.; Adams, Noah S.; Beeman, John W.; Eiler, John H.

    2012-01-01

    Telemetry provides a powerful and flexible tool for studying fish and other aquatic animals, and its use has become increasingly commonplace. However, telemetry is gear intensive and typically requires more specialized knowledge and training than many other field techniques. As with other scientific methods, collecting good data is dependent on an understanding of the underlying principles behind the approach, knowing how to use the equipment and techniques properly, and recognizing what to do with the data collected. This book provides a road map for using telemetry to study aquatic animals, and provides the basic information needed to plan, implement, and conduct a telemetry study under field conditions. Topics include acoustic or radio telemetry study design, tag implantation techniques, radio and acoustic telemetry principles and case studies, and data management and analysis.

  8. [Design of a lithium-ion battery recharging circuit used in wireless electrical stimulation apparatus for urinary incontinence].

    Science.gov (United States)

    Wang, Xiao-yuan; Hu, Chao; Yao, Yong; Wang, Hai-bin

    2008-09-01

    We introduce in this paper a novel design of the lithium-ion battery automatically-charging circuit used in portable wireless electronic stimulation therapeutic apparatus for urinary incontinence, including its working principles, structure and characteristic.

  9. Applying an intelligent and automated emissions measurement system to characterize the RF environment for supporting wireless technologies

    International Nuclear Information System (INIS)

    Keebler, P. F.; Phipps, K. O.

    2006-01-01

    The use of wireless technologies in commercial and industrial facilities has grown significantly in the past several years. New applications of wireless technologies with increasing frequency and varying radiated power are being developed everyday. Wireless application specialists and end users have already identified several sources of electromagnetic interference (EMI) in these facilities. Interference has been reported between wireless devices and between these devices and other types of electronic equipment either using frequencies in the unlicensed wireless spectrum or equipment that may generate undesired man-made noise in this spectrum. Facilities that are not using the wireless band should verify the spectral quality of that band and the electromagnetic compatibility (EMC) integrity of safety-related power and signal cables before installing wireless technologies. With the introduction of new wireless devices in the same electromagnetic space where analog and digital I and C systems and cables must co-exist, the ability of facility managers to manage their spectra will dictate the degree of interference between wireless devices and other electronic equipment. Because of the unknowns associated with interference with analog and digital I and C systems in the wireless band, nuclear power plants have been slow to introduce wireless technologies in plant areas. With the application of newly developed advanced radiated emissions measurement systems that can record, process, and analyze radiated and conducted emissions in a cost-effective manner, facility managers can more reliably characterize potential locations for wireless technologies, including potential coupling effects with safety-related power and signal cables, with increased confidence that the risks associated with creating an interference can be significantly reduced. This paper will present an effective philosophy already being used in other mission-critical applications for managing EMC, an

  10. Video ambulatory EEG: A good alternative to inpatient video telemetry?

    Science.gov (United States)

    Kandler, Rosalind; Ponnusamy, Athi; Wragg, Claire

    2017-04-01

    Video ambulatory EEG (V-AEEG) is a new technique which could add increased capacity for long term EEG monitoring to overstretched inpatient video telemetry (IPVT) services. We compare V-AEEG and IPVT for diagnostic efficacy, recording quality, patient acceptability and technologist time required. Forty-one V-AEEG and 64 IPVT adult patients were included. Patients were investigated to diagnose attacks or to obtain polysomnography (PSG) prior to multiple sleep latency test (MSLT). Number of attacks recorded, whether the diagnostic question was answered, quality of video and EEG recording and patients' preference for investigation at home or in hospital were noted. For V-AEEG patients, ease of procedure and extra technologist time required were recorded. Of patients investigated for diagnosis of attacks, 74% V-AEEG patients and 62% IPVT had typical attacks during the investigation. All PSGs were useful in interpreting the MSLTs. Diagnostic questions were answered by 73% V-AEEGs and 73% IPVTs. Quality of EEG and video recording was similar using V-AEEG and IPVT. Four patients had difficulty using V-AEEG equipment but diagnostic information was lost in only one. 5% of V-AEEG patients would have preferred hospital investigation but 45% of IPVT patients would have preferred home investigation. Extra technologist time for home visits (mean 2h) was required only for the first 7 patients. Video EEG recording quality and diagnostic efficacy from V-AEEG are similar to IPVT. V-AEEG is acceptable to most patients and does not require additional technical time. Hence, V-AEEG offers a convenient, economical alternative to IPVT. Copyright © 2017 British Epilepsy Association. Published by Elsevier Ltd. All rights reserved.

  11. Telemetry Monitoring and Display Using LabVIEW

    Science.gov (United States)

    Wells, George; Baroth, Edmund C.

    1993-01-01

    The Measurement Technology Center of the Instrumentation Section configures automated data acquisition systems to meet the diverse needs of JPL's experimental research community. These systems are based on personal computers or workstations (Apple, IBM/Compatible, Hewlett-Packard, and Sun Microsystems) and often include integrated data analysis, visualization and experiment control functions in addition to data acquisition capabilities. These integrated systems may include sensors, signal conditioning, data acquisition interface cards, software, and a user interface. Graphical programming is used to simplify configuration of such systems. Employment of a graphical programming language is the most important factor in enabling the implementation of data acquisition, analysis, display and visualization systems at low cost. Other important factors are the use of commercial software packages and off-the-shelf data acquisition hardware where possible. Understanding the experimenter's needs is also critical. An interactive approach to user interface construction and training of operators is also important. One application was created as a result of a competative effort between a graphical programming language team and a text-based C language programming team to verify the advantages of using a graphical programming language approach. With approximately eight weeks of funding over a period of three months, the text-based programming team accomplished about 10% of the basic requirements, while the Macintosh/LabVIEW team accomplished about 150%, having gone beyond the original requirements to simulate a telemetry stream and provide utility programs. This application verified that using graphical programming can significantly reduce software development time. As a result of this initial effort, additional follow-on work was awarded to the graphical programming team.

  12. Traffic Profiling in Wireless Sensor Networks

    National Research Council Canada - National Science Library

    Kirykos, Georgios

    2006-01-01

    .... Wireless sensor networks pose unique challenges and limitations to the traditional schemes, which are used in the other wireless networks for security protection, and are due mainly to the increased...

  13. CMOS circuits for passive wireless microsystems

    CERN Document Server

    Yuan, Fei

    2011-01-01

    Here is a comprehensive examination of CMOS circuits for passive wireless microsystems. Covers design challenges, fundamental issues of ultra-low power wireless communications, radio-frequency power harvesting, and advanced design techniques, and more.

  14. Wireless Sensor Portal Technology, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Mobitrum Corporation has demonstrated the feasibility in the Phase I of " A Wireless Sensor Portal Technology" and proposes a Phase II effort to develop a wireless...

  15. Kali Linux wireless penetration testing beginner's guide

    CERN Document Server

    Ramachandran, Vivek

    2015-01-01

    If you are a security professional, pentester, or anyone interested in getting to grips with wireless penetration testing, this is the book for you. Some familiarity with Kali Linux and wireless concepts is beneficial.

  16. Wireless Sensor Network for Electric Transmission Line Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Alphenaar, Bruce

    2009-06-30

    Generally, federal agencies tasked to oversee power grid reliability are dependent on data from grid infrastructure owners and operators in order to obtain a basic level of situational awareness. Since there are many owners and operators involved in the day-to-day functioning of the power grid, the task of accessing, aggregating and analyzing grid information from these sources is not a trivial one. Seemingly basic tasks such as synchronizing data timestamps between many different data providers and sources can be difficult as evidenced during the post-event analysis of the August 2003 blackout. In this project we investigate the efficacy and cost effectiveness of deploying a network of wireless power line monitoring devices as a method of independently monitoring key parts of the power grid as a complement to the data which is currently available to federal agencies from grid system operators. Such a network is modeled on proprietary power line monitoring technologies and networks invented, developed and deployed by Genscape, a Louisville, Kentucky based real-time energy information provider. Genscape measures transmission line power flow using measurements of electromagnetic fields under overhead high voltage transmission power lines in the United States and Europe. Opportunities for optimization of the commercial power line monitoring technology were investigated in this project to enable lower power consumption, lower cost and improvements to measurement methodologies. These optimizations were performed in order to better enable the use of wireless transmission line monitors in large network deployments (perhaps covering several thousand power lines) for federal situational awareness needs. Power consumption and cost reduction were addressed by developing a power line monitor using a low power, low cost wireless telemetry platform known as the ''Mote''. Motes were first developed as smart sensor nodes in wireless mesh networking applications

  17. A wireless trust model for healthcare.

    Science.gov (United States)

    Wickramasinghe, Nilmini; Misra, Santosh K

    2004-01-01

    In today's context of escalating costs, managed care, regulations such as the Health Insurance Portability and Accountability Act (HIPAA) and a technology savvy patient, the healthcare industry can no longer be complacent regarding embracing technologies to enable better, more effective and efficient practice management. In such an environment, many healthcare organisations are turning to m-commerce or wireless solutions. These solutions, in particular the mobile electronic patient record, have many advantages over their wired counterparts, including significant cost advantages, higher levels of physician acceptance, more functionalities as well as enabling easy accessibility to healthcare in remote geographic regions, however, they also bring with them challenges of their own. One such major challenge is security. To date, few models exist that help establish an appropriate framework, in the context of wireless in healthcare, in which to understand and evaluate all the security issues let alone facilitate the development of systematic and robust solutions. Our paper addresses this need by outlining an appropriate mobile trust model for such a scenario in healthcare organisations.

  18. Development and application of a modified wireless tracer for disaster prevention

    Science.gov (United States)

    Chung Yang, Han; Su, Chih Chiang

    2016-04-01

    Typhoon-induced flooding causes water overflow in a river channel, which results in general and bridge scour and soil erosion, thus leading to bridge failure, debris flow and landslide collapse. Therefore, dynamic measurement technology should be developed to assess scour in channels and landslide as a disaster-prevention measure against bridge failure and debris flow. This paper presents a wireless tracer that enables monitoring general scour in river channels and soil erosion in hillsides. The wireless tracer comprises a wireless high-power radio modem, various electronic components, and a self-designed printed circuit board that are all combined with a 9-V battery pack and an auto switch. The entire device is sealed in a jar by silicon. After it was modified, the wireless tracer underwent the following tests for practical applications: power continuation and durability, water penetration, and signal transmission during floating. A regression correlation between the wireless tracer's transmission signal and distance was also established. This device can be embedded at any location where scouring is monitored, and, in contrast to its counterparts that detect scour depth by identifying and analyzing received signals, it enables real-time observation of the scouring process. In summary, the wireless tracer developed in this study provides a dynamic technology for real-time monitoring of scouring (or erosion) and forecasting of landslide hazards. Keywords: wireless tracer; scour; real-time monitoring; landslide hazard.

  19. Detection of QTc interval prolongation using jacket telemetry in conscious non-human primates: comparison with implanted telemetry.

    Science.gov (United States)

    Derakhchan, K; Chui, R W; Stevens, D; Gu, W; Vargas, H M

    2014-01-01

    During repeat-dose toxicity studies, ECGs are collected from chemically or physically-restrained animals over a short timeframe. This is problematic due to cardiovascular changes caused by manual restraint stress and anesthesia, and limited ECG sampling. These factors confound data interpretation, but may be overcome by using a non-invasive jacket-based ECG collection (JET). The current study investigated whether a jacketed external telemetry system could detect changes in cardiac intervals and heart rate in non-human primates (NHPs), previously implanted with a PCT transmitter. Twelve male cynomolgus monkeys were treated weekly with vehicle or sotalol (8, 16, 32 mg kg⁻¹) p.o. ECGs were collected continuously for 24 hours, following treatment, over 4 weeks. A satellite group of six NHPs was used for sotalol toxicokinetics. Sotalol attained Cmax values 1-3 hours after dosing, and exhibited dose-proportional exposure. In jacketed NHPs, sotalol dose-dependently increased QT/QTc intervals, prolonged PR interval, and reduced heart rate. Significant QTc prolongation of 27, 54 and 76 msec was detected by JET after 8, 16, and 32 mg kg⁻¹ sotalol, respectively, compared with time-matched vehicle-treated animals. Overall, JET-derived PR, QT, QTc intervals, QRS duration, and heart rate correlated well with those derived from PCT. The current findings clearly support the use of JET to quantify cardiac interval and rhythm changes, capable of detecting QTc prolongation caused by sotalol. JET may be a preferred method compared to restraint-based ECG because high-density ECG sampling can be collected in unstressed conscious monkeys, over several weeks. © 2013 The British Pharmacological Society.

  20. A strategy for recovering continuous behavioral telemetry data from Pacific walruses

    Science.gov (United States)

    Fischbach, Anthony S.; Jay, Chadwick V.

    2016-01-01

    Tracking animal behavior and movement with telemetry sensors can offer substantial insights required for conservation. Yet, the value of data collected by animal-borne telemetry systems is limited by bandwidth constraints. To understand the response of Pacific walruses (Odobenus rosmarus divergens) to rapid changes in sea ice availability, we required continuous geospatial chronologies of foraging behavior. Satellite telemetry offered the only practical means to systematically collect such data; however, data transmission constraints of satellite data-collection systems limited the data volume that could be acquired. Although algorithms exist for reducing sensor data volumes for efficient transmission, none could meet our requirements. Consequently, we developed an algorithm for classifying hourly foraging behavior status aboard a tag with limited processing power. We found a 98% correspondence of our algorithm's classification with a test classification based on time–depth data recovered and characterized through multivariate analysis in a separate study. We then applied our algorithm within a telemetry system that relied on remotely deployed satellite tags. Data collected by these tags from Pacific walruses across their range during 2007–2015 demonstrated the consistency of foraging behavior collected by this strategy with data collected by data logging tags; and demonstrated the ability to collect geospatial behavioral chronologies with minimal missing data where recovery of data logging tags is precluded. Our strategy for developing a telemetry system may be applicable to any study requiring intelligent algorithms to continuously monitor behavior, and then compress those data into meaningful information that can be efficiently transmitted.

  1. STUDY & SURVEY ON WIRELESS CHARGING & TECHNOLOGY

    OpenAIRE

    Harshal Sharma*

    2016-01-01

    In the modern world, we have often heard a word- wireless charging technology. Actually what is it all about? So this paper is giving you the whole package about wireless charging technology. Wireless charging is a technology through which power is transmitted through an air gap to the electrical devices for the motive of replenishment of energy. At present wireless charging techniques and development of commercial products have provided a promise to address the energy bottleneck of portable ...

  2. A Forensic Readiness Model for Wireless Networks

    OpenAIRE

    Ngobeni, Sipho; Venter, Hein; Burke, Ivan

    2010-01-01

    International audience; Over the past decade, wireless mobile communications technology based on IEEE 802.11 wireless local area networks (WLANs) has been adopted worldwide on a massive scale. However, as the number of wireless users has soared, so has the possibility of cyber crime, where criminals deliberately and actively break into WLANs with the intent to cause harm or access sensitive information. WLAN digital forensics is seen not only as a response to cyber crime in wireless environme...

  3. Security Threats on Wireless Sensor Network Protocols

    OpenAIRE

    H. Gorine; M. Ramadan Elmezughi

    2016-01-01

    In this paper, we investigate security issues and challenges facing researchers in wireless sensor networks and countermeasures to resolve them. The broadcast nature of wireless communication makes Wireless Sensor Networks prone to various attacks. Due to resources limitation constraint in terms of limited energy, computation power and memory, security in wireless sensor networks creates different challenges than wired network security. We will discuss several attempts at addressing the issue...

  4. Wireless Inductive Power Device Suppresses Blade Vibrations

    Science.gov (United States)

    Morrison, Carlos R.; Provenza, Andrew J.; Choi, Benjamin B.; Bakhle, Milind A.; Min, James B.; Stefko, George L.; Duffy, Kirsten P.; Fougers, Alan J.

    2011-01-01

    Vibration in turbomachinery can cause blade failures and leads to the use of heavier, thicker blades that result in lower aerodynamic efficiency and increased noise. Metal and/or composite fatigue in the blades of jet engines has resulted in blade destruction and loss of lives. Techniques for suppressing low-frequency blade vibration, such as gtuned circuit resistive dissipation of vibratory energy, h or simply "passive damping," can require electronics incorporating coils of unwieldy dimensions and adding unwanted weight to the rotor. Other approaches, using vibration-dampening devices or damping material, could add undesirable weight to the blades or hub, making them less efficient. A wireless inductive power device (WIPD) was designed, fabricated, and developed for use in the NASA Glenn's "Dynamic Spin Rig" (DSR) facility. The DSR is used to simulate the functionality of turbomachinery. The relatively small and lightweight device [10 lb (approx.=4.5 kg)] replaces the existing venerable and bulky slip-ring. The goal is the eventual integration of this technology into actual turbomachinery such as jet engines or electric power generators, wherein the device will facilitate the suppression of potentially destructive vibrations in fan blades. This technology obviates slip rings, which require cooling and can prove unreliable or be problematic over time. The WIPD consists of two parts: a remote element, which is positioned on the rotor and provides up to 100 W of electrical power to thin, lightweight piezoelectric patches strategically placed on/in fan blades; and a stationary base unit that wirelessly communicates with the remote unit. The base unit supplies inductive power, and also acts as an input and output corridor for wireless measurement, and active control command to the remote unit. Efficient engine operation necessitates minimal disturbance to the gas flow across the turbine blades in any effort to moderate blade vibration. This innovation makes it

  5. A multi-channel low-power system-on-chip for single-unit recording and narrowband wireless transmission of neural signal.

    Science.gov (United States)

    Bonfanti, A; Ceravolo, M; Zambra, G; Gusmeroli, R; Spinelli, A S; Lacaita, A L; Angotzi, G N; Baranauskas, G; Fadiga, L

    2010-01-01

    This paper reports a multi-channel neural recording system-on-chip (SoC) with digital data compression and wireless telemetry. The circuit consists of a 16 amplifiers, an analog time division multiplexer, an 8-bit SAR AD converter, a digital signal processor (DSP) and a wireless narrowband 400-MHz binary FSK transmitter. Even though only 16 amplifiers are present in our current die version, the whole system is designed to work with 64 channels demonstrating the feasibility of a digital processing and narrowband wireless transmission of 64 neural recording channels. A digital data compression, based on the detection of action potentials and storage of correspondent waveforms, allows the use of a 1.25-Mbit/s binary FSK wireless transmission. This moderate bit-rate and a low frequency deviation, Manchester-coded modulation are crucial for exploiting a narrowband wireless link and an efficient embeddable antenna. The chip is realized in a 0.35- εm CMOS process with a power consumption of 105 εW per channel (269 εW per channel with an extended transmission range of 4 m) and an area of 3.1 × 2.7 mm(2). The transmitted signal is captured by a digital TV tuner and demodulated by a wideband phase-locked loop (PLL), and then sent to a PC via an FPGA module. The system has been tested for electrical specifications and its functionality verified in in-vivo neural recording experiments.

  6. Roll-to-roll paper sensors (ROPAS); Wireless communicating sensors on paper in the logistic chain

    NARCIS (Netherlands)

    Rentrop, C.; Rubingh, J.E.J.M.; Lelieveld, R.; Sandberg, H.

    2014-01-01

    The ROPAS project (Roll-to-roll paper sensors) combines high end electronics and wireless sensors with low cost paper substrates and processing techniques that can be applied on a large scale. Paper is the next step in the printed electronics roadmap of utilising cheaper substrate materials as a

  7. Proposal of Wireless Traffic Control Schemes for Wireless LANs

    Science.gov (United States)

    Hiraguri, Takefumi; Ichikawa, Takeo; Iizuka, Masataka; Kubota, Shuji

    This paper proposes two traffic control schemes to support the communication quality of multimedia streaming services such as VoIP and audio/video over IEEE 802.11 wireless LAN systems. The main features of the proposed scheme are bandwidth control for each flow of the multimedia streaming service and load balancing between access points (APs) of the wireless LAN by using information of data link, network and transport layers. The proposed schemes are implemented on a Linux machine which is called the wireless traffic controller (WTC). The WTC connects a high capacity backbone network and an access network to which the APs are attached. We evaluated the performance of the proposed WTC and confirmed that the communication quality of the multimedia streaming would be greatly improved by using this technique.

  8. Energy storage management system with distributed wireless sensors

    Science.gov (United States)

    Farmer, Joseph C.; Bandhauer, Todd M.

    2015-12-08

    An energy storage system having a multiple different types of energy storage and conversion devices. Each device is equipped with one or more sensors and RFID tags to communicate sensor information wirelessly to a central electronic management system, which is used to control the operation of each device. Each device can have multiple RFID tags and sensor types. Several energy storage and conversion devices can be combined.

  9. Selected Developments in Wireless Power Transfer Standards and Regulations

    OpenAIRE

    Kalialakis, Christos; Borges Carvalho, Nuno; Shinohara, Naoki; Georgiadis, Apostolos

    2016-01-01

    Selected advances in the use and developments of Wireless Power Transfer(WPT) standards and regulations in Europe and Japan are reported. The European research program COST-WiPE is described as a means to enhance interaction between research and standardization. WPT electronics are also reviewed in terms of frequency based on recent publications. Furthermore, activities in the context of International Telecommunications Union and especially recent Japanese contributions with a focus on far fi...

  10. Techniques for Wireless Applications

    KAUST Repository

    Gaaloul, Fakhreddine

    2012-05-01

    Switching techniques have been first proposed as a spacial diversity techniques. These techniques have been shown to reduce considerably the processing load while letting multi-antenna systems achieve a specific target performance. In this thesis, we take a different look at the switching schemes by implementing them for different other wireless applications. More specifically, this thesis consists of three main parts, where the first part considers a multiuser environment and an adaptive scheduling algorithm based on the switching with post-selection scheme for statistically independent but non-identically distributed channel conditions. The performance of this switched based scheduler is investigated and a multitude of performance metrics are presented. In a second part, we propose and analyze the performance of three switched-based algorithms for interference reduction in the downlink of over-loaded femtocells. For instance, performance metrics are derived in closed-form and these metrics are used to compare these three proposed schemes. Finally in a third part, a switch based opportunistic channel access scheme is proposed for a cognitive radio system and its performance is analyzed in terms of two new proposed metrics namely the average cognitive radio access and the waiting time duration.

  11. Wireless capsule endo bronchoscopy

    Directory of Open Access Journals (Sweden)

    Baratz DM

    2014-03-01

    Full Text Available No abstract available. Article truncated at 150 words. Case Presentation History of Present Illness A 67 year-old man presents 10 days after swallowing a capsule endoscopy camera that was never retrieved. The wireless capsule was swallowed asymptomatically for evaluation of heme positive stools after negative upper and lower endoscopies. Patient noted that the evening after swallowing the camera he developed mild shortness of breath and cough. The cough and shortness of breath were persistent and worsened while lying down and when moving positions. He denied prior issues with swallowing or aspiration. Review of Systems Negative other than what is noted above. PMH, SH, and FH Past medical history: coronary artery disease, peripheral vascular disease, hyperlipidemia Surgical history: femoral-popliteal bypass, previous shoulder and back surgery Social history: 1 pack/day of cigarettes for 50 years, prior alcohol usage but not current, no illicit drugs Family history: no pulmonary diseases Physical Exam Vital signs: temperature 36.7º C, heart rate 86 beats per minute ...

  12. Advanced Wireless Sensor Nodes - MSFC

    Science.gov (United States)

    Varnavas, Kosta; Richeson, Jeff

    2017-01-01

    NASA field center Marshall Space Flight Center (Huntsville, AL), has invested in advanced wireless sensor technology development. Developments for a wireless microcontroller back-end were primarily focused on the commercial Synapse Wireless family of devices. These devices have many useful features for NASA applications, good characteristics and the ability to be programmed Over-The-Air (OTA). The effort has focused on two widely used sensor types, mechanical strain gauges and thermal sensors. Mechanical strain gauges are used extensively in NASA structural testing and even on vehicle instrumentation systems. Additionally, thermal monitoring with many types of sensors is extensively used. These thermal sensors include thermocouples of all types, resistive temperature devices (RTDs), diodes and other thermal sensor types. The wireless thermal board will accommodate all of these types of sensor inputs to an analog front end. The analog front end on each of the sensors interfaces to the Synapse wireless microcontroller, based on the Atmel Atmega128 device. Once the analog sensor output data is digitized by the onboard analog to digital converter (A/D), the data is available for analysis, computation or transmission. Various hardware features allow custom embedded software to manage battery power to enhance battery life. This technology development fits nicely into using numerous additional sensor front ends, including some of the low-cost printed circuit board capacitive moisture content sensors currently being developed at Auburn University.

  13. WIRELESS FIDELITY (Wi-Fi) BROADBAND NETWORK ...

    African Journals Online (AJOL)

    ES Obe

    categorized into two types: fixed and mobile wireless. The broadband fixed wireless network technologies .... 3.0 WIRELESS FIDELITYF (Wi-Fi). NETWORK IMPLEMENTATION. A Wi-Fi enabled device such as a PC, game .... Amateur radio, video senders, and cordless phones, can cause significant additional interference.

  14. WirelessHART modeling and performance evaluation

    NARCIS (Netherlands)

    Remke, Anne Katharina Ingrid; Wu, Xian

    2013-01-01

    In process industries wired supervisory and control networks are more and more replaced by wireless systems. Wireless communication inevitably introduces time delays and message losses, which may degrade the system reliability and performance. WirelessHART, as the first international standard for

  15. Wireless power transfer inspired by the modern trends in electromagnetics

    Science.gov (United States)

    Song, Mingzhao; Belov, Pavel; Kapitanova, Polina

    2017-06-01

    Since the beginning of the 20th century, researchers have been looking for an effective way to transfer power without wired connections, but the wireless power transfer technology started to attract extensive interest from the industry side only in 2007 when the first smartphone was released and a consumer electronics revolution was triggered. Currently, the modern technology of wireless power transfer already has a rich research and development history as well as outstanding advances in commercialization. This review is focused on the description of distinctive implementations of this technology inspired by the modern trends in electrodynamics. We compare the performances of the power transfer systems based on three kinds of resonators, i.e., metallic coil resonators, dielectric resonators, and cavity mode resonators. We argue that metamaterials and meta-atoms are powerful tools to improve the functionalities and to obtain novel properties of the systems. We review different approaches to enhance the functionality of the wireless power transfer systems including control of the power transfer path and increase of the operation range and efficiency. Various applications of wireless power transfer are discussed and currently available standards are reviewed.

  16. Energy generation for an ad hoc wireless sensor network-based monitoring system using animal head movement

    DEFF Research Database (Denmark)

    S. Nadimi, Esmaeil; Blanes-Vidal, Victoria; Jørgensen, Rasmus Nyholm

    2011-01-01

    The supply of energy to electronics is an imperative constraining factor to be considered during the design process of mobile ad hoc wireless sensor networks (MANETs). This influence is especially important when the MANET is deployed unattended or the wireless modules within the MANET are not eas......The supply of energy to electronics is an imperative constraining factor to be considered during the design process of mobile ad hoc wireless sensor networks (MANETs). This influence is especially important when the MANET is deployed unattended or the wireless modules within the MANET...... are not easily accessible. Therefore, exploring novel sources of energy generation rather than operating electronics only on limited power supplies such as batteries is a major challenge. Monitoring free-ranging animal behavior is an application in which the entities (animals) within the MANET are not readily...

  17. TELEMETRY AND TELECOMMAND SYSTEM OF LOW-EARTH-ORBIT MICROSATELLITE, KITSAT-1 AND 2

    Directory of Open Access Journals (Sweden)

    Sungheon Kim

    1996-06-01

    Full Text Available The telecommand system of KITSAT micorsatellite receives commands from ground stations or on-board computers. It decodes, validates and delivers commands to sub-system. The telemetry system is to collect, process and format satellite housekeeping and mission data for use by on-board computer and ground station. It is crucial for the telemetry and telecommand system to have high reliability since the spacecraft operation is mostly based on the function of this system. The telemetry and telecommand(TTC systems for KITSAT-1 and 2 had been developed under the consideratin of the space environment of Low-Earth-Orbit and the limited mass, volume and power of micorsatellite. Since both satellites were launched in August 1992 and September 1993 respectively, the have shown to be working successfully as well as the TTC systems on-board both satellites.

  18. Optimization of data coils in a multiband wireless link for neuroprosthetic implantable devices.

    Science.gov (United States)

    Uei-Ming Jow; Ghovanloo, M

    2010-10-01

    We have presented the design methodology along with detailed simulation and measurement results for optimizing a multiband transcutaneous wireless link for high-performance implantable neuroprosthetic devices. We have utilized three individual carrier signals and coil/antenna pairs for power transmission, forward data transmission from outside into the body, and back telemetry in the opposite direction. Power is transmitted at 13.56 MHz through a pair of printed spiral coils (PSCs) facing each other. Two different designs have been evaluated for forward data coils, both of which help to minimize power carrier interference in the received data carrier. One is a pair of perpendicular coils that are wound across the diameter of the power PSCs. The other design is a pair of planar figure-8 coils that are in the same plane as the power PSCs. We have compared the robustness of each design against horizontal misalignments and rotations in different directions. Simulation and measurements are also conducted on a miniature spiral antenna, designed to operate with impulse-radio ultra-wideband (IR-UWB) circuitry for back telemetry.

  19. Wireless device monitoring systems and monitoring devices, and associated methods

    Science.gov (United States)

    McCown, Steven H; Derr, Kurt W; Rohde, Kenneth W

    2014-05-27

    Wireless device monitoring systems and monitoring devices include a communications module for receiving wireless communications of a wireless device. Processing circuitry is coupled with the communications module and configured to process the wireless communications to determine whether the wireless device is authorized or unauthorized to be present at the monitored area based on identification information of the wireless device. Methods of monitoring for the presence and identity of wireless devices are also provided.

  20. Impact of wireless link quality across communication layers

    OpenAIRE

    Zhou, J.

    2010-01-01

    Nowadays, wireless networks are used in most of the applications with radio technologies being used in all kinds of wireless networks. In all wireless links, the transmitted packets can be lost. How to identify the quality of a certain wireless link and achieve the best delivery performance over a certain wireless network is an open issue. In this thesis, the performance of wireless mesh network, wireless sensor network and cellular network have been investigated by the method of measurements...

  1. Applications of modern sensors and wireless technology in effective wound management.

    Science.gov (United States)

    Mehmood, Nasir; Hariz, Alex; Fitridge, Robert; Voelcker, Nicolas H

    2014-05-01

    The management of chronic wounds has emerged as a major health care challenge during the 21st century consuming, significant portions of health care budgets. Chronic wounds such as diabetic foot ulcers, leg ulcers, and pressure sores have a significant negative impact on the quality of life of affected individuals. Covering wounds with suitable dressings facilitates the healing process and is common practice in wound management plans. However, standard dressings do not provide insights into the status of the wound underneath. Parameters such as moisture, pressure, temperature and pH inside the dressings are indicative of the healing rate, infection, and wound healing phase. But owing to the lack of information available from within the dressings, these are often changed to inspect the wound, disturbing the normal healing process of wounds in addition to causing pain to the patient. Sensors embedded in the dressing would provide clinicians and nurses with important information that would aid in wound care decision making, improve patient comfort, and reduce the frequency of dressing changes. The potential benefits of this enabling technology would be seen in terms of a reduction in hospitalization time and health care cost. Modern sensing technology along with wireless radio frequency communication technology is poised to make significant advances in wound management. This review discusses issues related to the design and implementation of sensor technology and telemetry systems both incorporated in wound dressings to devise an automated wound monitoring technology, and also surveys the literature available on current sensor and wireless telemetry systems. Copyright © 2013 Wiley Periodicals, Inc.

  2. Flip-chip integrated optical wireless transceivers

    Science.gov (United States)

    O'Brien, Dominic C.; Faulkner, Grahame E.; Zyambo, Emmanuel B.; Edwards, David J.; Stavrinou, Paul N.; Parry, Gareth; Bellon, Jacques; Sibley, Martin J. N.; Lalithambika, Vinod A.; Joyner, Valencia M.; Samsudin, Rina J.; Holburn, David M.; Mears, Robert J.

    2002-12-01

    The widespread use of Optical LANs is dependent on the ability to fabricate low cost transceiver components. These are usually complex, and fabrication involves the integration of optoelectronic and electronic devices, as well as optical components. A consortium of four UK universities are currently involved in a project to demonstrate integrated optical wireless transceiver subsystems that can provide eye-safe line of sight in-building communication at 155Mbit/s and above. In this paper we discuss the flip-chip integration of two-dimensional arrays of novel microcavity LEDs with custom CMOS integrated circuits in order to produce solid state tracking emitters. Design, fabrication and integration of these structures are detailed. The scaleability and future capability available given further optimisation and development of these systems is also discussed.

  3. A Multi-Sensor RSS Spatial Sensing-Based Robust Stochastic Optimization Algorithm for Enhanced Wireless Tethering

    CERN Document Server

    Parasuraman, Ramviyas; Molinari, Luca; Kershaw, Keith; Di Castro, Mario; Masi, Alessandro; Ferre, Manuel

    2014-01-01

    The reliability of wireless communication in a network of mobile wireless robot nodes depends on the received radio signal strength (RSS). When the robot nodes are deployed in hostile environments with ionizing radiations (such as in some scientific facilities), there is a possibility that some electronic components may fail randomly (due to radiation effects), which causes problems in wireless connectivity. The objective of this paper is to maximize robot mission capabilities by maximizing the wireless network capacity and to reduce the risk of communication failure. Thus, in this paper, we consider a multi-node wireless tethering structure called the “server-relay-client” framework that uses (multiple) relay nodes in between a server and a client node. We propose a robust stochastic optimization (RSO) algorithm using a multi-sensor-based RSS sampling method at the relay nodes to efficiently improve and balance the RSS between the source and client nodes to improve the network capacity and to provide red...

  4. Wireless Augmented Reality Communication System

    Science.gov (United States)

    Devereaux, Ann (Inventor); Jedrey, Thomas (Inventor); Agan, Martin (Inventor)

    2017-01-01

    A portable unit is for video communication to select a user name in a user name network. A transceiver wirelessly accesses a communication network through a wireless connection to a general purpose node coupled to the communication network. A user interface can receive user input to log on to a user name network through the communication network. The user name network has a plurality of user names, at least one of the plurality of user names is associated with a remote portable unit, logged on to the user name network and available for video communication.

  5. OFDM systems for wireless communications

    CERN Document Server

    Narasimhamurthy, Adarsh

    2010-01-01

    Orthogonal Frequency Division Multiplexing (OFDM) systems are widely used in the standards for digital audio/video broadcasting, WiFi and WiMax. Being a frequency-domain approach to communications, OFDM has important advantages in dealing with the frequency-selective nature of high data rate wireless communication channels. As the needs for operating with higher data rates become more pressing, OFDM systems have emerged as an effective physical-layer solution.This short monograph is intended as a tutorial which highlights the deleterious aspects of the wireless channel and presents why OFDM is

  6. Embracing interference in wireless systems

    CERN Document Server

    Gollakota, Shyamnath

    2014-01-01

    The wireless medium is a shared resource. If nearby devices transmit at thesame time, their signals interfere, resulting in a collision. In traditionalnetworks, collisions cause the loss of the transmitted information. For thisreason, wireless networks have been designed with the assumption thatinterference is intrinsically harmful and must be avoided.This book, a revised version of the author's award-winning Ph.D.dissertation, takes an alternate approach: Instead of viewing interferenceas an inherently counterproductive phenomenon that should to be avoided, wedesign practical systems that tra

  7. The Wireless Nursing Call System

    DEFF Research Database (Denmark)

    Jensen, Casper Bruun

    2006-01-01

    This paper discusses a research project in which social scientists were involved both as analysts and supporters during a pilot with a new wireless nursing call system. The case thus exemplifies an attempt to participate in developing dependable health care systems and offers insight into the cha......This paper discusses a research project in which social scientists were involved both as analysts and supporters during a pilot with a new wireless nursing call system. The case thus exemplifies an attempt to participate in developing dependable health care systems and offers insight...

  8. Artificial intelligence in wireless communications

    CERN Document Server

    Rondeau, Thomas W

    2009-01-01

    This cutting-edge resource offers practical overview of cognitive radio, a paradigm for wireless communications in which a network or a wireless node changes its transmission or reception parameters. The alteration of parameters is based on the active monitoring of several factors in the external and internal radio environment. This book offers a detailed description of cognitive radio and its individual parts. Practitioners learn how the basic processing elements and their capabilities are implemented as modular components. Moreover, the book explains how each component can be developed and t

  9. Emerging wireless networks concepts, techniques and applications

    CERN Document Server

    Makaya, Christian

    2011-01-01

    An authoritative collection of research papers and surveys, Emerging Wireless Networks: Concepts, Techniques, and Applications explores recent developments in next-generation wireless networks (NGWNs) and mobile broadband networks technologies, including 4G (LTE, WiMAX), 3G (UMTS, HSPA), WiFi, mobile ad hoc networks, mesh networks, and wireless sensor networks. Focusing on improving the performance of wireless networks and provisioning better quality of service and quality of experience for users, it reports on the standards of different emerging wireless networks, applications, and service fr

  10. Principles of wireless access and localization

    CERN Document Server

    Pahlavan, Kaveh

    2013-01-01

    A comprehensive, encompassing and accessible text examining a wide range of key Wireless Networking and Localization technologies This book provides a unified treatment of issues related to all wireless access and wireless localization techniques.  The book reflects principles of design and deployment of infrastructure for wireless access and localization for wide, local, and personal networking.   Description of wireless access methods includes design and deployment of traditional TDMA and CDMA technologies and emerging Long Term Evolution (LTE) techniques for wide area cellular networks, the

  11. In-Flight Fault Diagnosis for Autonomous Aircraft Via Low-Rate Telemetry Channel

    DEFF Research Database (Denmark)

    Blanke, Mogens; Hansen, Søren

    2012-01-01

    An in-flight diagnosis system that is able to detect faults on an unmanned aircraft using real-time telemetry data could provide operator assistance to warn about imminent risks due to faults. However, limited bandwidth of the air-ground radio-link makes diagnosis difficult. Loss of information...... about rapid dynamic changes and high parameter uncertainty are the main difficulties. This paper explores time-domain relations in received telemetry signals and uses knowledge of aircraft dynamics and the mechanics behind physical faults to obtain a set of greybox models for diagnosis. Relating...

  12. Fiber Wireless Transmission of 8.3 Gb/s/ch QPSK-OFDM Signals in 75-110 GHz Band

    DEFF Research Database (Denmark)

    Deng, Lei; Beltrán Ramírez, Marta; Pang, Xiaodan

    2012-01-01

    In this paper, we present a scalable high speed Wband (75-110 GHz) fiber wireless communication system. By using an optical frequency comb generator, 3-channel 8.3 Gb/s/ch optical orthogonal frequency division multiplexing (OOFDM) baseband signals in a 15 GHz bandwidth are seamlessly translated...... from the optical to the wireless domain. The W-band wireless carrier is generated from heterodyne mixing the OOFDM baseband signal with a free-running laser. A W-band electronic down-converter and a digital signal processing (DSP) based receiver is used. 3-channel QPSK-OFDM W-band wireless signals...

  13. Efficient Wireless Charger Deployment for Wireless Rechargeable Sensor Networks

    Directory of Open Access Journals (Sweden)

    Jehn-Ruey Jiang

    2016-08-01

    Full Text Available A wireless rechargeable sensor network (WRSN consists of sensor nodes that can harvest energy emitted from wireless chargers for refilling their batteries so that the WRSN can operate sustainably. This paper assumes wireless chargers are equipped with directional antennas, and are deployed on grid points of a fixed height to propose two heuristic algorithms solving the following wireless charger deployment optimization (WCDO problem: how to deploy as few as possible chargers to make the WRSN sustainable. Both algorithms model the charging space of chargers as a cone and calculate charging efficiency according power regression expressions complying with the Friis transmission equation. The two algorithms are the greedy cone covering (GCC algorithm and the adaptive cone covering (ACC algorithm. The GCC (respectively, ACC algorithm greedily (respectively, adaptively generates candidate cones to cover as many as possible sensor nodes. Both algorithms then greedily select the fewest number of candidate cones, each of which corresponds to the deployment of a charger, to have approximate solutions to the WCDO problem. We perform experiments, conduct simulations and do analyses for the algorithms to compare them in terms of the time complexity, the number of chargers deployed, and the execution time.

  14. Introduction to Ultra Wideband for Wireless Communications

    DEFF Research Database (Denmark)

    Nikookar, Homayoun; Prasad, Ramjee

    Ultra Wideband (UWB) Technology is the cutting edge technology for wireless communications with a wide range of applications. In Introduction to Ultra Wideband for Wireless Communications UWB principles and technologies for wireless communications are explained clearly. Key issues such as UWB...... wireless channels, interference, signal processing as well as applications and standardization activities are addressed. Introduction to Ultra Wideband for Wireless Communications provides easy-to-understand material to (graduate) students and researchers working in the field of commercial UWB wireless...... communications. Due to tutorial nature of the book it can also be adopted as a textbook on the subject in the Telecommunications Engineering curriculum. Problems at the end of each chapter extend the reader's understanding of the subject. Introduction to Ultra Wideband for Wireless Communications will aslo...

  15. A wireless sensor tag platform for container security and integrity

    Science.gov (United States)

    Amaya, Ivan A.; Cree, Johnathan V.; Mauss, Fredrick J.

    2011-04-01

    Cargo containers onboard ships are widely used in the global supply chain. The need for container security is evidenced by the Container Security Initiative launched by the U.S. Bureau of Customs and Border Protection (CBP). One method of monitoring cargo containers is using low power wireless sensor tags. The wireless sensor tags are used to set up a network that is comprised of tags internal to the container and a central device. The sensor network reports alarms and other anomalies to a central device, which then relays the message to an outside network upon arrival at the destination port. This allows the port authorities to have knowledge of potential security or integrity issues before physically examining the container. Challenges of using wireless sensor tag networks for container security include battery life, size, environmental conditions, information security, and cost among others. PNNL developed an active wireless sensor tag platform capable of reporting data wirelessly to a central node as well as logging data to nonvolatile memory. The tags, operate at 2.4 GHz over an IEEE 802.15.4 protocol, and were designed to be distributed throughout the inside of a shipping container in the upper support frame. The tags are mounted in a housing that allows for simple and efficient installation or removal prior to, during, or after shipment. The distributed tags monitor the entire container volume. The sensor tag platform utilizes low power electronics and provides an extensible sensor interface for incorporating a wide range of sensors including chemical, biological, and environmental sensors.

  16. An Overview of the Development of High Temperature Wireless Smart Sensor Technology

    Science.gov (United States)

    Hunter, Gary W.

    2014-01-01

    The harsh environment inherent in propulsion systems is especially challenging for Smart Sensor Systems; this paper addresses technology development for such applications. A basic sensing system for high temperature wireless pressure monitoring composed of a sensor, electronics, and wireless communication with scavenged power developed for health monitoring of aircraft engines and other high temperature applications has been demonstrated at 475 C. Other efforts will be discussed including a brief overview of the status of high temperature electronics and sensors, as well as their use and applications.

  17. Wireless Power for Mobile Devices

    NARCIS (Netherlands)

    Waffenschmidt, E.

    2011-01-01

    Wireless power transfer allows a convenient, easy to use battery charging of mobile phones and other mobile devices. No hassle with cables and plugs, just place the device on a pad and that’s it. Such asystem even has the potential to become a standard charging solution. Where are the limits for

  18. Socially Aware Heterogeneous Wireless Networks.

    Science.gov (United States)

    Kosmides, Pavlos; Adamopoulou, Evgenia; Demestichas, Konstantinos; Theologou, Michael; Anagnostou, Miltiades; Rouskas, Angelos

    2015-06-11

    The development of smart cities has been the epicentre of many researchers' efforts during the past decade. One of the key requirements for smart city networks is mobility and this is the reason stable, reliable and high-quality wireless communications are needed in order to connect people and devices. Most research efforts so far, have used different kinds of wireless and sensor networks, making interoperability rather difficult to accomplish in smart cities. One common solution proposed in the recent literature is the use of software defined networks (SDNs), in order to enhance interoperability among the various heterogeneous wireless networks. In addition, SDNs can take advantage of the data retrieved from available sensors and use them as part of the intelligent decision making process contacted during the resource allocation procedure. In this paper, we propose an architecture combining heterogeneous wireless networks with social networks using SDNs. Specifically, we exploit the information retrieved from location based social networks regarding users' locations and we attempt to predict areas that will be crowded by using specially-designed machine learning techniques. By recognizing possible crowded areas, we can provide mobile operators with recommendations about areas requiring datacell activation or deactivation.

  19. Underwater optical wireless communication network

    Science.gov (United States)

    Arnon, Shlomi

    2010-01-01

    The growing need for underwater observation and subsea monitoring systems has stimulated considerable interest in advancing the enabling technologies of underwater wireless communication and underwater sensor networks. This communication technology is expected to play an important role in investigating climate change, in monitoring biological, biogeochemical, evolutionary, and ecological changes in the sea, ocean, and lake environments, and in helping to control and maintain oil production facilities and harbors using unmanned underwater vehicles (UUVs), submarines, ships, buoys, and divers. However, the present technology of underwater acoustic communication cannot provide the high data rate required to investigate and monitor these environments and facilities. Optical wireless communication has been proposed as the best alternative to meet this challenge. Models are presented for three kinds of optical wireless communication links: (a) a line-of-sight link, (b) a modulating retroreflector link, and (c) a reflective link, all of which can provide the required data rate. We analyze the link performance based on these models. From the analysis, it is clear that as the water absorption increases, the communication performance decreases dramatically for the three link types. However, by using the scattered light it was possible to mitigate this decrease in some cases. It is concluded from the analysis that a high-data-rate underwater optical wireless network is a feasible solution for emerging applications such as UUV-to-UUV links and networks of sensors, and extended ranges in these applications could be achieved by applying a multi-hop concept.

  20. Data centric wireless sensor networks

    NARCIS (Netherlands)

    Dulman, S.O.; Havinga, Paul J.M.

    2005-01-01

    The vision of wirteless sensing systems requires the development of devices and technologies that can be pervasive without being intrusive. The basic component of such a smart environment will be a small node with sensing and wireless communications capabilities, able to organize itself flexibly

  1. Wireless Crew Communication Feasibility Assessment

    Science.gov (United States)

    Archer, Ronald D.; Romero, Andy; Juge, David

    2016-01-01

    Ongoing discussions with crew currently onboard the ISS as well as the crew debriefs from completed ISS missions indicate that issues associated with the lack of wireless crew communication results in increased crew task completion times and lower productivity, creates cable management issues, and increases crew frustration.

  2. Deployable Wireless Camera Penetrators

    Science.gov (United States)

    Badescu, Mircea; Jones, Jack; Sherrit, Stewart; Wu, Jiunn Jeng

    2008-01-01

    A lightweight, low-power camera dart has been designed and tested for context imaging of sampling sites and ground surveys from an aerobot or an orbiting spacecraft in a microgravity environment. The camera penetrators also can be used to image any line-of-sight surface, such as cliff walls, that is difficult to access. Tethered cameras to inspect the surfaces of planetary bodies use both power and signal transmission lines to operate. A tether adds the possibility of inadvertently anchoring the aerobot, and requires some form of station-keeping capability of the aerobot if extended examination time is required. The new camera penetrators are deployed without a tether, weigh less than 30 grams, and are disposable. They are designed to drop from any altitude with the boost in transmitting power currently demonstrated at approximately 100-m line-of-sight. The penetrators also can be deployed to monitor lander or rover operations from a distance, and can be used for surface surveys or for context information gathering from a touch-and-go sampling site. Thanks to wireless operation, the complexity of the sampling or survey mechanisms may be reduced. The penetrators may be battery powered for short-duration missions, or have solar panels for longer or intermittent duration missions. The imaging device is embedded in the penetrator, which is dropped or projected at the surface of a study site at 90 to the surface. Mirrors can be used in the design to image the ground or the horizon. Some of the camera features were tested using commercial "nanny" or "spy" camera components with the charge-coupled device (CCD) looking at a direction parallel to the ground. Figure 1 shows components of one camera that weighs less than 8 g and occupies a volume of 11 cm3. This camera could transmit a standard television signal, including sound, up to 100 m. Figure 2 shows the CAD models of a version of the penetrator. A low-volume array of such penetrator cameras could be deployed from an

  3. REAL-TIME TRACER MONITORING OF RESERVOIR STIMULATION PROCEDURES VIA ELECTRONIC WIRELINE AND TELEMETRY DATA TRANSMISSION

    Energy Technology Data Exchange (ETDEWEB)

    George L. Scott III

    2005-01-01

    Finalized Phase 2-3 project work has field-proven two separate real-time reservoir processes that were co-developed via funding by the National Energy Technology Laboratory (NETL). Both technologies are presently patented in the United States and select foreign markets; a downhole-commingled reservoir stimulation procedure and a real-time tracer-logged fracturing diagnostic system. Phase 2 and early Phase 3 project work included the research, development and well testing of a U.S. patented gamma tracer fracturing diagnostic system. This stimulation logging process was successfully field-demonstrated; real-time tracer measurement of fracture height while fracturing was accomplished and proven technically possible. However, after the initial well tests, there were several licensing issues that developed between service providers that restricted and minimized Realtimezone's (RTZ) ability to field-test the real-time gamma diagnostic system as was originally outlined for this project. Said restrictions were encountered after when one major provider agreed to license their gamma logging tools to another. Both of these companies previously promised contributory support toward Realtimezone's DE-FC26-99FT40129 project work, however, actual support was less than desired when newly-licensed wireline gamma logging tools from one company were converted by the other from electric wireline into slickline, batter-powered ''memory'' tools for post-stimulation logging purposes. Unfortunately, the converted post-fracture measurement memory tools have no applications in experimentally monitoring real-time movement of tracers in the reservoir concurrent with the fracturing treatment. RTZ subsequently worked with other tracer gamma-logging tool companies for basic gamma logging services, but with lessened results due to lack of multiple-isotope detection capability. In addition to real-time logging system development and well testing, final Phase 2 and Phase 3 project work included the development of a real-time reservoir stimulation procedure, which was successfully field-demonstrated and is presently patented in the U.S. and select foreign countries, including Venezuela, Brazil and Canada. Said patents are co-owned by RTZ and the National Energy Technology Lab (NETL). In 2002, Realtimezone and the NETL licensed said patents to Halliburton Energy Services (HES). Additional licensing agreements (LA) are anticipated with other service industry companies in 2005. Final Phase 3 work has led to commercial applications of the real-time reservoir stimulation procedure. Four successfully downhole-mixed well tests were conducted with commercially expected production results. The most recent, fourth field test was a downhole-mixed stimulated well completed in June, 2004, which currently produces 11 BOPD with 90 barrels of water per day. Conducted Phase 2 and Phase 3 field-test work to date has resulted in the fine-tuning of a real-time enhanced stimulation system that will significantly increase future petroleum well recoveries in the United States and foreign petroleum fields, both onshore and offshore, and in vertical and horizontal wells.

  4. REAL-TIME TRACER MONITORING OF RESERVOIR STIMULATION PROCEDURES VIA ELECTRONIC WIRELINE AND TELEMETRY DATA TRANSMISSION

    Energy Technology Data Exchange (ETDEWEB)

    George Scott III

    2003-08-01

    Ongoing Phase 2-3 work comprises the final development and field-testing of two complementary real-time reservoir technologies; a stimulation process and a tracer fracturing diagnostic system. Initial DE-FC26-99FT40129 project work included research, development, and testing of the patented gamma tracer fracturing diagnostic system. This process was field-proven to be technically useful in providing tracer measurement of fracture height while fracturing; however, technical licensing restrictions blocked Realtimezone from fully field-testing this real-time gamma diagnostic system, as originally planned. Said restrictions were encountered during Phase 2 field test work as result of licensing limitations and potential conflicts between service companies participating in project work, as related to their gamma tracer logging tool technology. Phase 3 work principally demonstrated field-testing of Realtimezone (RTZ) and NETL's Downhole-mixed Reservoir Stimulation process. Early on, the simplicity of and success of downhole-mixing was evident from well tests, which were made commercially productive. A downhole-mixed acid stimulation process was tested successfully and is currently commercially used in Canada. The fourth well test was aborted due to well bore conditions, and an alternate test project is scheduled April, 2004. Realtimezone continues to effectuate ongoing patent protection in the United States and foreign markets. In 2002, Realtimezone and the NETL licensed their United States patent to Halliburton Energy Services (HES). Additional licensing arrangements with other industry companies are anticipated in 2004-2005. Ongoing Phase 2 and Phase 3 field-testing continues to confirm applications of both real-time technologies. Technical data transfer to industry is ongoing via Internet tech-transfer and various industry presentations and publications including Society of Petroleum Engineers. These real-time enhanced stimulation procedures should significantly increase future petroleum well recoveries in the United States, onshore and offshore, and in vertical and horizontal wells.

  5. Acoustic telemetry validates a citizen science approach for monitoring sharks on coral reefs.

    Science.gov (United States)

    Vianna, Gabriel M S; Meekan, Mark G; Bornovski, Tova H; Meeuwig, Jessica J

    2014-01-01

    Citizen science is promoted as a simple and cost-effective alternative to traditional approaches for the monitoring of populations of marine megafauna. However, the reliability of datasets collected by these initiatives often remains poorly quantified. We compared datasets of shark counts collected by professional dive guides with acoustic telemetry data from tagged sharks collected at the same coral reef sites over a period of five years. There was a strong correlation between the number of grey reef sharks (Carcharhinus amblyrhynchos) observed by dive guides and the telemetry data at both daily and monthly intervals, suggesting that variation in relative abundance of sharks was detectable in datasets collected by dive guides in a similar manner to data derived from telemetry at these time scales. There was no correlation between the number or mean depth of sharks recorded by telemetry and the presence of tourist divers, suggesting that the behaviour of sharks was not affected by the presence of divers during our study. Data recorded by dive guides showed that current strength and temperature were important drivers of the relative abundance of sharks at monitored sites. Our study validates the use of datasets of shark abundance collected by professional dive guides in frequently-visited dive sites in Palau, and supports the participation of experienced recreational divers as contributors to long-term monitoring programs of shark populations.

  6. Comparison of Diagnostic Information from Regular Telemetry Equipment and a Novel Patch Type Electrocardiogram Recorder

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt; Egstrup, Kenneth; Hoppe, Karsten

    2014-01-01

    The purpose of this pilot study is to compare the diagnostic information obtained using regular telemetry equipment and the novel ePatch heart monitor. The comparison was conducted by a cardiologist on 24-hour recordings from 11 admitted patients. For all 11 recordings, the same diagnostic inform...

  7. Effects of angling and manual handling on pike behaviour investigated by high-resolution positional telemetry

    DEFF Research Database (Denmark)

    Baktoft, Henrik; Aarestrup, Kim; Berg, Søren

    2013-01-01

    Human disturbances such as angling and manual handling may have long-term effects on the behaviour of pike, Esox lucius L., an ecologically important species. Using continuous high-resolution positional telemetry, this study compared the swimming activity of handled and unhandled pike in a small...

  8. Telemetry Standards, IRIG Standard 106-17. Chapter 10. Digital Recording Standard

    Science.gov (United States)

    2017-07-01

    formatting characters, representing the numeric date on which the file was created (e.g., BCS codes for the decimal digits 02092000...Telemetry Standards, IRIG Standard 106-17 Chapter 10, July 2017 CHAPTER 10 Digital Recording Standard Acronyms...10-v Chapter 10. Digital Recording Standard

  9. Telemetry-based oxygen sensor for continuous monitoring of kidney oxygenation in conscious rats.

    Science.gov (United States)

    Koeners, Maarten P; Ow, Connie P C; Russell, David M; Abdelkader, Amany; Eppel, Gabriela A; Ludbrook, John; Malpas, Simon C; Evans, Roger G

    2013-06-15

    The precise roles of hypoxia in the initiation and progression of kidney disease remain unresolved. A major technical limitation has been the absence of methods allowing long-term measurement of kidney tissue oxygen tension (Po₂) in unrestrained animals. We developed a telemetric method for the measurement of kidney tissue Po₂ in unrestrained rats, using carbon paste electrodes (CPEs). After acute implantation in anesthetized rats, tissue Po₂ measured by CPE-telemetry in the inner cortex and medulla was in close agreement with that provided by the "gold standard" Clark electrode. The CPE-telemetry system could detect small changes in renal tissue Po₂ evoked by mild hypoxemia. In unanesthetized rats, CPE-telemetry provided stable measurements of medullary tissue Po₂ over days 5-19 after implantation. It also provided reproducible responses to systemic hypoxia and hyperoxia over this time period. There was little evidence of fibrosis or scarring after 3 wk of electrode implantation. However, because medullary Po₂ measured by CPE-telemetry was greater than that documented from previous studies in anesthetized animals, this method is presently best suited for monitoring relative changes rather than absolute values. Nevertheless, this new technology provides, for the first time, the opportunity to examine the temporal relationships between tissue hypoxia and the progression of renal disease.

  10. National Training Course. Emergency Medical Technician. Paramedic. Instructor's Lesson Plans. Module XV. Telemetry and Communications.

    Science.gov (United States)

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This instructor's lesson plan guide on telemetry and communications is one of fifteen modules designed for use in the training of emergency medical technicians (paramedics). Two units of study are presented: (1) emergency medical services communications systems (items of equipment and such radio communications concepts as frequency allocation,…

  11. New telemetry device for the measurement of gastrointestinal motility in rats and comparison with standard equipment.

    Science.gov (United States)

    Meile, Tobias; Zieker, Derek; Königsrainer, Alfred; Glatzle, Jörg

    2015-04-01

    To perform stress-free recording of gastrointestinal motility in rats with strain gauge transducers, telemetry equipment had to be developed. We developed, programmed, and tested a new telemetry device that records gastrointestinal motility in freely moving rats using strain gauge transducers. The device can collect and transmit data in freely moving rats. Data are received and stored for later analysis with a regular PC. Linear calibration curves were obtained for the strain gauge transducers used. We compared data obtained with the new telemetry device with data gathered with standard equipment and could not find any statistically significant difference. Wired gastric and colonic contraction frequencies were 4.6 ± 0.3 per minute and 1.5 ± 0.3 per minute, whereas telemetric contraction frequencies were 4.4 ± 0.1 per minute and 1.25 ± 0.1 per minute. The new telemetry device is a very useful tool for the measurement of gastrointestinal motility in rats.

  12. Telemetry Option in the Measurement of Physical Activity for Patients with Heart Failure

    Science.gov (United States)

    Melczer, Csaba; Melczer, László; Oláh, András; Sélleyné-Gyúró, Mónika; Welker, Zsanett; Ács, Pongrác

    2015-01-01

    Measurement of physical activity among patients with heart failure typically requires a special approach due to the patients' physical status. Nowadays, a technology is already available that can measure the kinematic movements in 3-D by a pacemaker and implantable defibrillator giving an assessment on software. The telemetry data can be…

  13. Manchester code telemetry system for well logging using quasi-parallel inductive-capacitive resonance

    Science.gov (United States)

    Xu, Lijun; Chen, Jianjun; Cao, Zhang; Liu, Xingbin; Hu, Jinhai

    2014-07-01

    In this paper, a quasi-parallel inductive-capacitive (LC) resonance method is proposed to improve the recovery of MIL-STD-1553 Manchester code with several frequency components from attenuated, distorted, and drifted signal for data telemetry in well logging, and corresponding telemetry system is developed. Required resonant frequency and quality factor are derived, and the quasi-parallel LC resonant circuit is established at the receiving end of the logging cable to suppress the low-pass filtering effect caused by the distributed capacitance of the cable and provide balanced pass for all the three frequency components of the Manchester code. The performance of the method for various encoding frequencies and cable lengths at different bit energy to noise density ratios (Eb/No) have been evaluated in the simulation. A 5 km single-core cable used in on-site well logging and various encoding frequencies were employed to verify the proposed telemetry system in the experiment. Results obtained demonstrate that the telemetry system is feasible and effective to improve the code recovery in terms of anti-attenuation, anti-distortion, and anti-drift performances, decrease the bit error rate, and increase the reachable transmission rate and distance greatly.

  14. Advances in cochlear implant telemetry: evoked neural responses, electrical field imaging, and technical integrity.

    NARCIS (Netherlands)

    Mens, L.H.M.

    2007-01-01

    During the last decade, cochlear implantation has evolved into a well-established treatment of deafness, predominantly because of many improvements in speech processing and the controlled excitation of the auditory nerve. Cochlear implants now also feature telemetry, which is highly useful to

  15. Loop migration in adult marsh harriers Circus aeruginosus, as revealed by satellite telemetry

    DEFF Research Database (Denmark)

    H. G. Klaassen, Raymond; Strandberg, Roine; Hake, Mikael

    2010-01-01

    level, for example by analysing ring recoveries. Here we study loop migration of individual marsh harriersCircus aeruginosus tracked by satellite telemetry. We show that despite a generally narrow migration corridor the harriers travelled in a distinct clockwise loop through Africa and southern Europe...

  16. Comparison of Diagnostic Information from Regular Telemetry Equipment and a Novel Patch Type Electrocardiogram Recorder

    DEFF Research Database (Denmark)

    Saadi, Dorthe Bodholt; Egstrup, Kenneth; Hoppe, Karsten

    2014-01-01

    The purpose of this pilot study is to compare the diagnostic information obtained using regular telemetry equipment and the novel ePatch heart monitor. The comparison was conducted by a cardiologist on 24-hour recordings from 11 admitted patients. For all 11 recordings, the same diagnostic...

  17. Telemetry research on elusive wildlife: A synthesis of studies on giant pandas.

    Science.gov (United States)

    Connor, Thomas; Hull, Vanessa; Liu, Jianguo

    2016-07-01

    Telemetry studies that track animals through space and time can lead to advances in scientific understanding that are vital in conservation efforts. For example, telemetry studies of the giant panda (Ailuropoda melanoleuca) have shed light on many aspects of panda biology, but small sample sizes in each separate study make it difficult to draw broad conclusions. To overcome this problem we conducted the first synthesis of all 5 panda telemetry studies conducted to date. Using these data we investigated patterns in 6 main topics: home range, space-use interactions, core areas, movement patterns, seasonal migration and natal dispersal. We found that panda home range sizes do not vary between 2 main mountain ranges (Qionglai and Qinling), as was previously believed. Our results also suggest that female pandas increase their movement in the mating season: a behavior typically attributed only to males. We found and summarized telemetry and genetic evidence for female natal dispersal in the giant panda. Our synthesis highlights the need for additional research relating panda behavior to human disturbance factors, and can aid future studies on giant pandas as well as other species. © 2016 International Society of Zoological Sciences, Institute of Zoology/Chinese Academy of Sciences and John Wiley & Sons Australia, Ltd.

  18. Miniaturized, low power FGMOSFET radiation sensor and wireless dosimeter system

    KAUST Repository

    Arsalan, Muhammad

    2013-08-27

    A miniaturized floating gate (FG) MOSFET radiation sensor system is disclosed, The sensor preferably comprises a matched pair of sensor and reference FGMOSFETs wherein the sensor FGMOSFET has a larger area floating gate with an extension over a field oxide layer, for accumulation of charge and increased sensitivity. Elimination of a conventional control gate and injector gate reduces capacitance, and increases sensitivity, and allows for fabrication using standard low cost CMOS technology. A sensor system may be provided with integrated signal processing electronics, for monitoring a change in differential channel current I.sub.D, indicative of radiation dose, and an integrated negative bias generator for automatic pre-charging from a low voltage power source. Optionally, the system may be coupled to a wireless transmitter. A compact wireless sensor System on Package solution is presented, suitable for dosimetry for radiotherapy or other biomedical applications.

  19. Wireless and mobile systems in telemedicine

    Directory of Open Access Journals (Sweden)

    Reza Safdari

    2012-12-01

    Full Text Available Background: It is necessary to deploy mobile and wireless systems in healthcare, because they have many benefits for healthcare systems. The objectives of this article were introducing various systems, applications, and standards of the wireless and mobile telemedicine. Material and Methods: This review study was conducted in 2010. To conduct the study, published articles in the years 2005 to 2012, in English with an emphasis on wireless and mobile technologies in health were studied. Search was done with key words include telemedicine, wireless health systems, health and telecommunications technology in databases including Pubmed, Science Direct, Google Scholar, Web of Sciences, Proquest. The collected data were analyzed. Results: Telemedicine system in the ambulance, telemedicine systems in space, telecardiology systems, EEG system, ultrasound system are some types of wireless and mobile systems in telemedicine. PDA-based mobile and wireless telemedicine application, based PDA drug application, and patient tracking application are some of wireless and mobile applications of telemedicine. The most important standards of wireless and mobile telemedicine are HL7, DICOM, SNOMed, and ICD-9-CM. Conclusion: There are many challenges in the wireless and mobile systems in telemedicine, despite the many benefits. Slow speed in sending pictures and video, lack of attention to the privacy in the design of these systems, environmental variables and the number of users during the day are some of these challenges. It is recommended to consider these challenges during the planning and designing of wireless and mobile systems in telemedicine.

  20. Cost-effectiveness of telemetry for hospitalized patients with low-risk chest pain.

    Science.gov (United States)

    Ward, Michael J; Eckman, Mark H; Schauer, Daniel P; Raja, Ali S; Collins, Sean

    2011-03-01

    The majority of chest pain admissions originate in the emergency department (ED). Despite a low incidence of cardiac events, limited telemetry availability, and its questionable benefit, these patients are routinely admitted to a monitored setting. The objectives were to analyze the cost-effectiveness of admission to telemetry versus admission to an unmonitored hospital bed in low-risk chest pain patients and explore when the use of telemetry may be cost-effective. The authors constructed a decision analytic model to evaluate the scenario of an ED admission of an otherwise healthy 55-year-old patient with low-risk chest pain defined as an acute coronary syndrome (ACS) probability of 2%. Costs were estimated from 2009 Medicare data for hospital reimbursement and physician services, as well as published data on disability costs. Published studies were used to estimate the risk of ACS, cardiac arrest, time to defibrillation, survival, long-term disability, and quality of life. In the base case, telemetry was more effective (0.0044 quality-adjusted life-years [QALYs]) but more costly ($299.67) than a floor bed, resulting in a high marginal cost-effectiveness ratio (mCER) of $67,484.55 per QALY. In comprehensive sensitivity analyses, the mCER crossed below the willingness-to-pay (WTP) threshold of $50,000 per QALY when the following scenarios were met: the probability of ACS exceeds 3%, the probability of cardiac arrest is greater than 0.4%, the probability of shockable dysrhythmia is above 83%, the probability of delay in telemetry bed availability is below 52%, and the opportunity cost of delay to telemetry bed placement is below $119. Telemetry may be a "cost-effective" use of health care resources for chest pain patients when patients have a probability of ACS above 3% or for patients with a minimal delay and cost associated with obtaining a monitored bed. Further research is needed to better stratify low-risk chest pain patients to the appropriate inpatient setting

  1. Preliminary validation of a new magnetic wireless blood pump.

    Science.gov (United States)

    Kim, Sung Hoon; Ishiyama, Kazushi; Hashi, Shuichiro; Shiraishi, Yasuyuki; Hayatsu, Yukihiro; Akiyama, Masatoshi; Saiki, Yoshikatsu; Yambe, Tomoyuki

    2013-10-01

    In general, a blood pump must be small, have a simple configuration, and have sufficient hydrodynamic performance. Herein, we introduce new mechanisms for a wireless blood pump that is small and simple and provides wireless and battery-free operation. To achieve wireless and battery-free operation, we implement magnetic torque and force control methods that use two external drivers: an external coil and a permanent magnet with a DC-motor, respectively. Power harvesting can be used to drive an electronic circuit for wireless monitoring (the observation of the pump conditions and temperature) without the use of an internal battery. The power harvesting will be used as a power source to drive other electronic devices, such as various biosensors with their driving circuits. To have both a compact size and sufficient pumping capability, the fully magnetic impeller has five stages and each stage includes four backward-curved blades. The pump has total and inner volumes of 20 and 9.8 cc, respectively, and weighs 52 g. The pump produces a flow rate of approximately 8 L/min at 80 mm Hg and the power generator produces 0.3 W of electrical power at 120 Ω. The pump also produces a minimum flow rate of 1.5 L/min and a pressure of 30 mm Hg for circulation at a maximum distance of 7.5 cm. © 2013 Wiley Periodicals, Inc. and International Center for Artificial Organs and Transplantation.

  2. Telemetry-based mortality estimates of juvenile spot in two North Carolina estuarine creeks

    Science.gov (United States)

    Friedl, Sarah E.; Buckel, Jeffery A.; Hightower, Joseph E.; Scharf, Frederick S.; Pollock, Kenneth H.

    2013-01-01

    We estimated natural mortality rates (M) of age-1 Spot Leiostomus xanthurus by using a sonic telemetry approach. Sonic transmitters were surgically implanted into a total of 123 age-1 Spot in two North Carolina estuarine creeks during spring 2009 and 2010, and the fish were monitored by using a stationary acoustic receiver array and manual tracking. Fates of telemetered Spot were inferred based on telemetry information from estimated locations and swimming speeds. Potential competitors of age-1 Spot were assessed through simultaneous otter trawl sampling, while potential predators of Spot were collected using gill nets and trammel nets. The number of inferred natural mortalities was zero in 2009 (based on 29 telemetered Spot at risk) and four in 2010 (based on 52 fish at risk), with fish being at risk for up to about 70 d each year. Catches of potential competitors or predators did not differ between years, and age-1 Spot were not found in analyzed stomach contents of potential predators. Our estimated 30-d M of 0.03 (95% credible interval = 0.01–0.07) was lower than that predicted from weight-based (M = 0.07) and life-history-based (M = 0.06–0.36) estimates. Our field-based estimate of M for age-1 Spot in this estuarine system can assist in the assessment and management of Spot by allowing a direct comparison with M-values predicted from fish size or life history characteristics. The field telemetry and statistical analysis techniques developed here provide guidance for future telemetry studies of relatively small fish in open, dynamic habitat systems, as they highlight strengths and weaknesses of using a telemetry approach to estimate M.

  3. Patient load effects on response time to critical arrhythmias in cardiac telemetry: a randomized trial.

    Science.gov (United States)

    Segall, Noa; Hobbs, Gene; Granger, Christopher B; Anderson, Amanda E; Bonifacio, Alberto S; Taekman, Jeffrey M; Wright, Melanie C

    2015-05-01

    Remotely monitored patients may be at risk for a delayed response to critical arrhythmias if the telemetry watchers who monitor them are subject to an excessive patient load. There are no guidelines or studies regarding the appropriate number of patients that a single watcher may safely and effectively monitor. Our objective was to determine the impact of increasing the number of patients monitored on response time to simulated cardiac arrest. Randomized trial. Laboratory-based experiment. Forty-two remote telemetry technicians and nurses from cardiac units. Number of patients monitored in a simulation of cardiac telemetry monitoring work. We carried out a study to compare response times to ventricular fibrillation across five patient loads: 16, 24, 32, 40, and 48 patients. The simulation replicated the work of telemetry watchers using a combination of real recorded patient electrocardiogram signals and a simulated patient experiencing ventricular fibrillation. Study participants were assigned to one of the five patient loads and completed a 4-hour monitoring session, during which they performed tasks-including event documentation and phone calls to report events-similar to real monitoring work. When the simulated patient sustained ventricular fibrillation, the time required to report this arrhythmia was recorded. As patient loads increased, there was a statistically significant increase in response times to the ventricular fibrillation. In addition, frequency of failure to meet a response time goal of less than 20 seconds was significantly higher in the 48-patient condition than in all other conditions. Task performance decreased as patient load increased. As participants monitored more patients in a laboratory setting, their performance with respect to recognizing critical and noncritical events declined. This study has implications for the design of remote telemetry work and other patient monitoring tasks in critical and intermediate care units.

  4. Power requirements and battery life measurement for wireless transmission between two nodes in different mediums

    Directory of Open Access Journals (Sweden)

    Radouane Karli

    2017-06-01

    Full Text Available One of the most important roles of the wireless sensor networks (WSN is to avoid wiring costs, be self-sustainable and be able to function for several years. However, due to the slow progress in battery technology, power continues to be a limited resource in wireless sensor communication and electric energy storage remains to be an important issue. On the other hand, if batteries must be replaced often, many remote sensing applications may become impractical. Therefore, batteries with long life on the order of several years are needed. This paper is an extension of work originally presented in The 5th International Conference on Electronic Devices, Systems and Applications to investigate further the power requirements for wireless data transfer between two nodes using batteries with different capacities (55 mAh, 550 mAh and 5500 mAh. In particular, the effect of a propagation medium such as air, distilled water and engine oil on the wireless communication inside a one meter long metallic pipe was investigated. Our first result shows a successful transmission of wireless signal through air, distilled water and oil medium with very low transmission losses. The second result shows that an increase in the battery capacity will increase the two-node wireless sensor operation time even in different propagation medium. This result can be used to determine the required battery capacity for extending the WSN operation time.

  5. Energy-efficient digital and wireless IC design for wireless smart sensing

    Science.gov (United States)

    Zhou, Jun; Huang, Xiongchuan; Wang, Chao; Tae-Hyoung Kim, Tony; Lian, Yong

    2017-10-01

    Wireless smart sensing is now widely used in various applications such as health monitoring and structural monitoring. In conventional wireless sensor nodes, significant power is consumed in wirelessly transmitting the raw data. Smart sensing adds local intelligence to the sensor node and reduces the amount of wireless data transmission via on-node digital signal processing. While the total power consumption is reduced compared to conventional wireless sensing, the power consumption of the digital processing becomes as dominant as wireless data transmission. This paper reviews the state-of-the-art energy-efficient digital and wireless IC design techniques for reducing the power consumption of the wireless smart sensor node to prolong battery life and enable self-powered applications.

  6. Surgical insertion of transmitters and telemetry methods in fisheries research

    DEFF Research Database (Denmark)

    Rub, A. Michelle Wargo; Jepsen, Niels; Liedtke, Theresa L.

    2014-01-01

    Use of electronic transmitter and monitoring systems to track movements of aquatic animals has increased continuously since the inception of these systems in the mid-1950s. The purpose of the present report is to provide information about veterinary principles and their incorporation into surgica...

  7. Adaptive Naive Bayes classification for wireless sensor networks

    NARCIS (Netherlands)

    Zwartjes, G.J.

    2017-01-01

    Wireless Sensor Networks are tiny devices equipped with sensors and wireless communication. These devices observe environments and communicatie about these observations. Machine Learning techniques are of interest for Wireless Sensor Network applications since they can reduce the amount of needed

  8. Realistic modeling of the biological channel for the design of implantable wireless UWB communication systems.

    Science.gov (United States)

    Bahrami, Hadi; Gosselin, Benoit; Rusch, Leslie A

    2012-01-01

    Several emerging medical applications require that a miniature data acquisition device be implanted into the head to extract and wirelessly communicate brain activity to other devices. Designing a reliable communication link for such an application requires a realistic model of the surrounding biological tissues. This paper exploits a realistic model of the biological channel to design a suitable wireless ultra wideband communication link in a brain monitoring application. Two scenarios for positioning the implanted transmitting antenna are considered. The 1(st) scenario places the antenna under the skull, whereas the 2(nd) scenario places the antenna under the skin, above the skull. The propagation characteristics of the signal through the tissues of the human head have been determined with full-wave electromagnetic simulation based on Finite Element Method. The implantable antenna and the external antenna are key components to establish an electromagnetic link between an implanted transmitter and an external receiver. The average specific absorption rate (ASAR) of the implantable antennas are evaluated and compared for the two proposed scenarios. Moreover, the maximum available power from the implanted antenna is evaluated to characterize the performance of the communication link established between the implantable antenna and the external antenna, with respect to spectrum and safety regulations. We show how sensitive the receiver must be in order to implement a reliable telemetry link based on the proposed model of the channel.

  9. A Fully Implantable Pacemaker for the Mouse: From Battery to Wireless Power

    Science.gov (United States)

    Zellmer, Erik R.; Weinheimer, Carla J.; MacEwan, Matthew R.; Cui, Sophia X.; Nerbonne, Jeanne M.; Efimov, Igor R.

    2013-01-01

    Animal models have become a popular platform for the investigation of the molecular and systemic mechanisms of pathological cardiovascular physiology. Chronic pacing studies with implantable pacemakers in large animals have led to useful models of heart failure and atrial fibrillation. Unfortunately, molecular and genetic studies in these large animal models are often prohibitively expensive or not available. Conversely, the mouse is an excellent species for studying molecular mechanisms of cardiovascular disease through genetic engineering. However, the large size of available pacemakers does not lend itself to chronic pacing in mice. Here, we present the design for a novel, fully implantable wireless-powered pacemaker for mice capable of long-term (>30 days) pacing. This design is compared to a traditional battery-powered pacemaker to demonstrate critical advantages achieved through wireless inductive power transfer and control. Battery-powered and wireless-powered pacemakers were fabricated from standard electronic components in our laboratory. Mice (n = 24) were implanted with endocardial, battery-powered devices (n = 14) and epicardial, wireless-powered devices (n = 10). Wireless-powered devices were associated with reduced implant mortality and more reliable device function compared to battery-powered devices. Eight of 14 (57.1%) mice implanted with battery-powered pacemakers died following device implantation compared to 1 of 10 (10%) mice implanted with wireless-powered pacemakers. Moreover, device function was achieved for 30 days with the wireless-powered device compared to 6 days with the battery-powered device. The wireless-powered pacemaker system presented herein will allow electrophysiology studies in numerous genetically engineered mouse models as well as rapid pacing-induced heart failure and atrial arrhythmia in mice. PMID:24194832

  10. Relation of Telemetry Use and Mortality Risk, Hospital Length of Stay, and Readmission Rates in Patients With Respiratory Illness.

    Science.gov (United States)

    Dawson, Nancy; Burton, M Caroline; Hull, Bryan; Beliles, Gregory; Pritchard, Ingrid; Trautman, Christopher; Ferry, Laura; Doyon, Amanda; Colby, Rebecca; Chuu, Andy; Kung, Shu Ting; Khang, Tran; Durocher, Donna; Buras, Matthew; Kosiorek, Heidi; Agrwal, Neera; Sen, Ayan; Goss, Darin; Geyer, Holly

    2017-10-15

    The 2004 American Heart Association expert opinion-based guidelines restrict telemetry use primarily to patients with current or high-risk cardiac conditions. Respiratory infections have emerged as a common source of hospitalization, and telemetry is frequently applied without indication in efforts to monitor patient decompensation. In this retrospective study, we aimed to determine whether telemetry impacts mortality risk, length of stay (LOS), or readmission rates in hospitalized patients with acute respiratory infection not meeting American Heart Association criteria. A total of 765 respiratory infection patient encounters with Diagnosis-Related Groups 193, 194, 195, 177, 178 and 179 admitted in 2013 to 2015 to 2 tertiary community-based medical centers (Mayo Clinic, Arizona, and Mayo Clinic, Florida) were evaluated, and outcomes between patients who underwent or did not undergo telemetry were compared. Overall, the median LOS was longer in patients who underwent telemetry (3.0 days vs 2.0 days, p Telemetry predicted LOS for both univariate (estimate 1.18, 95% confidence interval 1.06 to 1.32, p = 0.003) and multivariate (estimate 1.17, 95% confidence interval 1.06 to 1.30, p = 0.003) analyses after controlling for severity of illness but did not predict patient mortality. In conclusion, this study identified that patients with respiratory infection who underwent telemetry without clear indications may face increased LOS without reducing their readmission risk or improving the overall mortality. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Performance Analysis of IIUM Wireless Campus Network

    International Nuclear Information System (INIS)

    Latif, Suhaimi Abd; Masud, Mosharrof H; Anwar, Farhat

    2013-01-01

    International Islamic University Malaysia (IIUM) is one of the leading universities in the world in terms of quality of education that has been achieved due to providing numerous facilities including wireless services to every enrolled student. The quality of this wireless service is controlled and monitored by Information Technology Division (ITD), an ISO standardized organization under the university. This paper aims to investigate the constraints of wireless campus network of IIUM. It evaluates the performance of the IIUM wireless campus network in terms of delay, throughput and jitter. QualNet 5.2 simulator tool has employed to measure these performances of IIUM wireless campus network. The observation from the simulation result could be one of the influencing factors in improving wireless services for ITD and further improvement

  12. Introductory survey for wireless infrared communications

    Directory of Open Access Journals (Sweden)

    Munsif Ali Jatoi

    2014-08-01

    Full Text Available Wireless infrared communications can be defined as the propagation of light waves in free space using infrared radiation whose range is 400–700 nm. This range corresponds to frequencies of hundreds of terahertz, which is high for higher data rate applications. Wireless infrared is applied for higher data rates applications such as wireless computing, wireless video and wireless multimedia communication applications. Introduced by Gfeller, this field has grown with different link configurations, improved transmitter efficiency, increased receiver responsivity and various multiple access techniques for improved quality. Errors are caused because of background light, which causes degradation overall system performance. Error correction techniques are used to remove the errors caused during transmission. This study provides a brief account on field theory used for error correction in wireless infrared systems. The results are produced in terms of bit error rate and signal-to-noise ratio for various bit lengths to show the ability of encoding and decoding algorithms.

  13. Wireless Network Penetration Testing and Security Auditing

    Directory of Open Access Journals (Sweden)

    Wang Shao-Long

    2016-01-01

    Full Text Available IEEE802.11 wireless wireless networks have security issues that are vulnerable to a variety of attacks. Due to using radio to transport data, attackers can bypass firewalls, sniff sensitive information, intercept packets and send malicious packets. Security auditing and penetration testing is expected to ensure wireless networks security. The contributions of this work are analyzed the vulnerability and types of attacks pertaining to IEEE 802.11 WLAN, performed well known attacks in a laboratory environment to conduct penetration tests to confirm whether our wireless network is hackable or not. WAIDPS is configured as auditing tool to view wireless attacks, such as WEP/WPA/WPA2 cracking, rouge access points, denial of service attack. WAIDPS is designed to detect wireless intrusion with additional features. Penetration testing and auditing will mitigate the risk and threatening to protect WALN.

  14. Wireless Technology Application to Nuclear Power Plants

    International Nuclear Information System (INIS)

    Lee, Jeong Kweon; Jeong, See Chae; Jeong, Ki Hoon; Oh, Do Young; Kim, Jae Hack

    2009-01-01

    Wireless technologies are getting widely used in various industrial processes for equipment condition monitoring, process measurement and other applications. In case of Nuclear Power Plant (NPP), it is required to review applicability of the wireless technologies for maintaining plant reliability, preventing equipment failure, and reducing operation and maintenance costs. Remote sensors, mobile technology and two-way radio communication may satisfy these needs. The application of the state of the art wireless technologies in NPPs has been restricted because of the vulnerability for the Electromagnetic Interference and Radio Frequency Interference (EMI/RFI) and cyber security. It is expected that the wireless technologies can be applied to the nuclear industry after resolving these issues which most of the developers and vendors are aware of. This paper presents an overview and information on general wireless deployment in nuclear facilities for future application. It also introduces typical wireless plant monitoring system application in the existing NPPs

  15. mm-Wave Hybrid Photonic Wireless Links for Ultra-High Speed Wireless Transmissions

    DEFF Research Database (Denmark)

    Rommel, Simon; Vegas Olmos, Juan José; Tafur Monroy, Idelfonso

    Hybrid photonic-wireless transmission schemes in the mm-wave frequency range are promising candidates to enable the multi-gigabit per second data communications required from wireless and mobile networks of the 5th and future generations. Large FCC spectrum allocations for wireless transmission...

  16. Application and promotion of wireless charging technology

    OpenAIRE

    Yan, Kaijun

    2014-01-01

    The aim of this thesis is to study wireless charging technology and analyze the application and promotion of each technology. This technology is based on Faraday’s electromagnetic in 1830s. It is not a new technology but it is developing high speed nowadays. This thesis introduces four mainstream types of wireless charging technology and three main-stream standards, and analyzes their features and development status. Wireless charging technology has been applied to some products, suc...

  17. Computer-Based Wireless Advertising Communication System

    Directory of Open Access Journals (Sweden)

    Anwar Al-Mofleh

    2009-10-01

    Full Text Available In this paper we developed a computer based wireless advertising communication system (CBWACS that enables the user to advertise whatever he wants from his own office to the screen in front of the customer via wireless communication system. This system consists of two PIC microcontrollers, transmitter, receiver, LCD, serial cable and antenna. The main advantages of the system are: the wireless structure and the system is less susceptible to noise and other interferences because it uses digital communication techniques.

  18. Application opportunities in wireless communications. Final report

    International Nuclear Information System (INIS)

    Abbott, R.E.; Blevins, R.P.; Olmstead, C.

    1998-07-01

    This report presents the results of examinations of wireless technologies and applications that may offer potential to utilities. Five different wireless technology areas are reviewed. Three areas--Communication Networks, Monitored Security Services, and Home Automation--potentially represent new business ventures for utilities. Two areas--Automatic Vehicle Location and Automated Field-Force Management--represent wireless applications with potential for reduced operating costs and improved customer relations

  19. Design and security of small wireless network

    OpenAIRE

    Žižka, Ladislav

    2012-01-01

    This thesis deals with design and security of small wireless network. Main goal of the thesis is home network design and choice of optimal solution of wireless security. The thesis has four parts. The first part describes computer networks and network components in theory. Next part deals with network design, choosing of network components and setting of them. It also describes some functionalities of alternative firmware DD-WRT. The third part presents common wireless security and network an...

  20. Feasibility and Applications of a Wireless Firewall

    OpenAIRE

    Wilhelm, Matthias

    2016-01-01

    Most of today’s wireless communication devices operate on unlicensed bands with uncoordinated spectrum access, with the consequence that RF interference and collisions are impairing the overall performance of wireless networks. In the classical design of network protocols, both packets in a collision are considered lost, such that channel access mechanisms attempt to avoid collisions proactively. However, with the current proliferation of wireless applications, e.g., WLANs, car-to-car network...

  1. Wireless Augmented Reality Communication System

    Science.gov (United States)

    Devereaux, Ann (Inventor); Jedrey, Thomas (Inventor); Agan, Martin (Inventor)

    2016-01-01

    The system of the present invention is a highly integrated radio communication system with a multimedia co-processor which allows true two-way multimedia (video, audio, data) access as well as real-time biomedical monitoring in a pager-sized portable access unit. The system is integrated in a network structure including one or more general purpose nodes for providing a wireless-to-wired interface. The network architecture allows video, audio and data (including biomedical data) streams to be connected directly to external users and devices. The portable access units may also be mated to various non-personal devices such as cameras or environmental sensors for providing a method for setting up wireless sensor nets from which reported data may be accessed through the portable access unit. The reported data may alternatively be automatically logged at a remote computer for access and viewing through a portable access unit, including the user's own.

  2. Propagation Engineering in Wireless Communications

    CERN Document Server

    Ghasemi, Abdollah; Ghasemi, Farshid

    2012-01-01

    Wireless communications has seen explosive growth in recent decades, in a realm that is both broad and rapidly expanding to include satellite services, navigational aids, remote sensing, telemetering, audio and video broadcasting, high-speed data communications, mobile radio systems and much more. Propagation Engineering in Wireless Communications deals with the basic principles of radiowaves propagation for frequency bands used in radio-communications, offering descriptions of new achievements and newly developed propagation models. The book bridges the gap between theoretical calculations and approaches, and applied procedures needed for advanced radio links design. The primary objective of this two-volume set is to demonstrate the fundamentals, and to introduce propagation phenomena and mechanisms that engineers are likely to encounter in the design and evaluation of radio links of a given type and operating frequency. Volume one covers basic principles, along with tropospheric and ionospheric propagation,...

  3. Mobility needs and wireless solutions

    DEFF Research Database (Denmark)

    Saugstrup, Dan; Henten, Anders

    The main purpose of this report is to spell out a methodological approach to the analysis of user needs with respect to mobility. Furthermore, this methodological approach is used in an exemplary analysis of the relationship between user needs and technology solutions offered by different wireless...... technologies. The report is based on a research approach, emphasizing important aspects in relation to developing more user oriented mobile services and applications in a heterogeneous network environment. As a staring point, Scandinavian research within the field of social science concerning mobility...... is described and discussed. Furthermore different wireless technologies are briefly described and discussed in relation to possible transmission capacities and coverage areas. In addition to this, a preliminary framework regarding the implications of mobility on the use and development of mobile services...

  4. Passive Wireless SAW Humidity Sensors, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal describes the preliminary development of passive wireless surface acoustic wave (SAW) based humidity sensors for NASA application to distributed...

  5. Distributed medium access control in wireless networks

    CERN Document Server

    Wang, Ping

    2013-01-01

    This brief investigates distributed medium access control (MAC) with QoS provisioning for both single- and multi-hop wireless networks including wireless local area networks (WLANs), wireless ad hoc networks, and wireless mesh networks. For WLANs, an efficient MAC scheme and a call admission control algorithm are presented to provide guaranteed QoS for voice traffic and, at the same time, increase the voice capacity significantly compared with the current WLAN standard. In addition, a novel token-based scheduling scheme is proposed to provide great flexibility and facility to the network servi

  6. EEM{sup TM} wireless supervision

    Energy Technology Data Exchange (ETDEWEB)

    Bilic, H. [Ericsson-Nikola Tesla d.d. Zagreb (Croatia)

    2000-07-01

    By adding the GSM network to the communication level of Energy Management systems, energy operating centres (EOC) can offer wireless access to the supervised equipment. Furthermore EOC can profit from rapid service development in the GSM networks. With implementation of GPRS to the GSM network EOC can instantly offer wireless access to external IP based networks such as Internet and corporate Intranets. The author describes architecture and key characteristic of Ericsson EnergyMaster{sup TM} (EEM{sup TM}) system for Energy Management, how and where to implement wireless supervision, wireless access to IP addresses and also how to implement new services provided by the GSM network. (orig.)

  7. Wireless SAW Interrogator and Sensor System Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Wireless, passive, Surface Acoustic Wave (SAW), Orthogonal Frequency Coded (OFC) temperature sensors, operating in a multi-sensor environment, developed at the...

  8. Wireless 3D Chocolate Printer

    OpenAIRE

    FROILAN G. DESTREZA; FRANCIS CARLO V. SOLLESTRE; MARJORIE V. VASQUEZ; FRANCIS B. MENDOZA

    2014-01-01

    This study is for the BSHRM Students of Batangas State University (BatStateU) ARASOF for the researchers believe that the Wireless 3D Chocolate Printer would be helpful in their degree program especially on making creative, artistic, personalized and decorative chocolate designs. The researchers used the Prototyping model as procedural method for the successful development and implementation of the hardware and software. This method has five phases which are the following: quick plan, quick d...

  9. Inkjet printed wireless smart bandage

    KAUST Repository

    Farooqui, Muhammad Fahad

    2016-12-19

    Chronic wounds affect millions of patients around the world and requires a major portion of health care budget for treatment. In this article, we present an unprecedented low cost continuous wireless monitoring system, realized through inkjet printing on a standard bandage strip, which can send early warnings as well as record long term wound progression data. The smart bandage can communicate upto a distance of 60 m when worn on the body.

  10. Smartphone Household Wireless Electroencephalogram Hat

    Directory of Open Access Journals (Sweden)

    Harold Szu

    2013-01-01

    Full Text Available Rudimentary brain machine interface has existed for the gaming industry. Here, we propose a wireless, real-time, and smartphone-based electroencephalogram (EEG system for homecare applications. The system uses high-density dry electrodes and compressive sensing strategies to overcome conflicting requirements between spatial electrode density, temporal resolution, and spatiotemporal throughput rate. Spatial sparseness is addressed by close proximity between active electrodes and desired source locations and using an adaptive selection of N active among 10N passive electrodes to form m-organized random linear combinations of readouts, m≪N≪10N. Temporal sparseness is addressed via parallel frame differences in hardware. During the design phase, we took tethered laboratory EEG dataset and applied fuzzy logic to compute (a spatiotemporal average of larger magnitude EEG data centers in 0.3 second intervals and (b inside brainwave sources by Independent Component Analysis blind deconvolution without knowing the impulse response function. Our main contributions are the fidelity of quality wireless EEG data compared to original tethered data and the speed of compressive image recovery. We have compared our recovery of ill-posed inverse data against results using Block Sparse Code. Future work includes development of strategies to filter unwanted artifact from high-density EEGs (i.e., facial muscle-related events and wireless environmental electromagnetic interferences.

  11. Augmenting forearm crutches with wireless sensors for lower limb rehabilitation

    International Nuclear Information System (INIS)

    Merrett, Geoff V; Ettabib, Mohamed A; White, Neil M; Peters, Christian; Hallett, Georgina

    2010-01-01

    Forearm crutches are frequently used in the rehabilitation of an injury to the lower limb. The recovery rate is improved if the patient correctly applies a certain fraction of their body weight (specified by a clinician) through the axis of the crutch, referred to as partial weight bearing (PWB). Incorrect weight bearing has been shown to result in an extended recovery period or even cause further damage to the limb. There is currently no minimally invasive tool for long-term monitoring of a patient's PWB in a home environment. This paper describes the research and development of an instrumented forearm crutch that has been developed to wirelessly and autonomously monitor a patient's weight bearing over the full period of their recovery, including its potential use in a home environment. A pair of standard forearm crutches are augmented with low-cost off-the-shelf wireless sensor nodes and electronic components to provide indicative measurements of the applied weight, crutch tilt and hand position on the grip. Data are wirelessly transmitted between crutches and to a remote computer (where they are processed and visualized in LabVIEW), and the patient receives biofeedback by means of an audible signal when they put too much or too little weight through the crutch. The initial results obtained highlight the capability of the instrumented crutch to support physiotherapists and patients in monitoring usage

  12. Unidirectional wireless power transfer using near-field plates

    Energy Technology Data Exchange (ETDEWEB)

    Imani, Mohammadreza F., E-mail: mohamad.imani@gmail.com [Center for Metamaterials and Integrated Plasmonics, Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Grbic, Anthony [Radiation Laboratory, Department of Electrical Engineering and Computer Science, University of Michigan, Ann Arbor, Michigan 48109 (United States)

    2015-05-14

    One of the obstacles preventing wireless power transfer from becoming ubiquitous is their leakage of power: high-amplitude electromagnetic fields that can interfere with other electronic devices, increase health concerns, or hinder power metering. In this paper, we present near-field plates (NFPs) as a novel method to tailor the electromagnetic fields generated by a wireless power transfer system while maintaining high efficiency. NFPs are modulated arrays or surfaces designed to form prescribed near-field patterns. The NFP proposed in this paper consists of an array of loaded loops that are designed to confine the electromagnetic fields of a resonant transmitting loop to the desired direction (receiving loop) while suppressing fields in other directions. The step-by-step design procedure for this device is outlined. Two NFPs are designed and examined in full-wave simulation. Their performance is shown to be in close agreement with the design predictions, thereby verifying the proposed design and operation. A NFP is also fabricated and experimentally shown to form a unidirectional wireless power transfer link with high efficiency.

  13. Integrated wireless neural interface based on the Utah electrode array.

    Science.gov (United States)

    Kim, S; Bhandari, R; Klein, M; Negi, S; Rieth, L; Tathireddy, P; Toepper, M; Oppermann, H; Solzbacher, F

    2009-04-01

    This report presents results from research towards a fully integrated, wireless neural interface consisting of a 100-channel microelectrode array, a custom-designed signal processing and telemetry IC, an inductive power receiving coil, and SMD capacitors. An integration concept for such a device was developed, and the materials and methods used to implement this concept were investigated. We developed a multi-level hybrid assembly process that used the Utah Electrode Array (UEA) as a circuit board. The signal processing IC was flip-chip bonded to the UEA using Au/Sn reflow soldering, and included amplifiers for up to 100 channels, signal processing units, an RF transmitter, and a power receiving and clock recovery module. An under bump metallization (UBM) using potentially biocompatible materials was developed and optimized, which consisted of a sputter deposited Ti/Pt/Au thin film stack with layer thicknesses of 50/150/150 nm, respectively. After flip-chip bonding, an underfiller was applied between the IC and the UEA to improve mechanical stability and prevent fluid ingress in in vivo conditions. A planar power receiving coil fabricated by patterning electroplated gold films on polyimide substrates was connected to the IC by using a custom metallized ceramic spacer and SnCu reflow soldering. The SnCu soldering was also used to assemble SMD capacitors on the UEA. The mechanical properties and stability of the optimized interconnections between the UEA and the IC and SMD components were measured. Measurements included the tape tests to evaluate UBM adhesion, shear testing between the Au/Sn solder bumps and the substrate, and accelerated lifetime testing of the long-term stability for the underfiller material coated with a a-SiC(x):H by PECVD, which was intended as a device encapsulation layer. The materials and processes used to generate the integrated neural interface device were found to yield a robust and reliable integrated package.

  14. Performance and utility of satellite telemetry during field studies of free-ranging polar bears in Alaska

    Science.gov (United States)

    Garner, Gerald W.; Amstrup, Steven C.; Douglas, David C.; Gardner, Craig L.; Amlaner, Charles J.

    1989-01-01

    Satellite telemetry technology has been used during field studies of polar bears in Alaska since 1985. A total of 109 Platform Transmitter Terminals (PTT) have been deployed on free-ranging female polar bears that seasonally inhabit waters adjacent to the Alaskan coast. The PTTs transmitted locational and sensor data to TIROS-N polar-orbiting satellites during a duty cycle of 12 hours on/60 hours off in 1985, 1986, and 1987. Expected battery life was 13.8 months, and collars were normally removed and replaced with new or refurbished PTTs at 11-13 month intervals. Duty cycles were altered to 7-8 hours on/64-65 hours off in 1988 to prolong expected battery life to 19-21 months. Sensor data transmitted included PTT internal temperature, short term activity counts recorded at 60 second intervals, and long term activity counts for the preceding 24 or 72-hour period. Early failures of PTTs to fix location (less than 75% of expected battery life) were as high as 53% during 198501986. Subsequent improvements in battery design, including better shock insulation, improved electronic, and an improved battery system have reduced early failures to 27% in 1987-1988. The harsh environment and the degree of abuse observed in recovered collars indicate that an unavoidable failure rate of 8-10% is inherent within 60 days after deployment on polar bears. A total of 18,000 locations and 201,000 sensor messages were received from female polar bears between May 1985 and June 1988. Polar bears that were marked in Alaskan waters have been located as far south as 60°N 168°W, and as far east as 70°N 127°W in the Beaufort Sea. Polar bears in the Beaufort Sea are shared with Canada, while polar bears in the Chukchi and Bering seas are shared with the Soviet Union. The international ranges of the two hypothesized populations have been documented. Satellite telemetry has detailed the large movement patterns of polar bear over these vast areas that were previously not available using other

  15. A WiMAX Networked UAV Telemetry System for Net-Centric Remote Sensing and Range Surveillance, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — A WiMAX networked UAV Telemetry System (WNUTS) is designed for net-centric remote sensing and launch range surveillance applications. WNUTS integrates a MIMO powered...

  16. An Architecture for Real-Time Processing of OSIRIS-REx Engineering and Science Data, from Raw Telemetry to PDS

    Science.gov (United States)

    Selznick, S. H.

    2017-06-01

    Herein we describe an architecture developed for processing engineering and science data for the OSIRIS-REx mission. The architecture is soup-to-nuts, starting with raw telemetry and ending with submission to PDS.

  17. Rays in the northern Gulf of Mexico: Aerial Survey and Satellite Telemetry 2008-2012 (NCEI Accession 0129495)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The dataset contains distribution and abundance data for rays in the Gulf of Mexico collected through aerial surveys and satellite telemetry. Aerial survey data...

  18. Monitoring and Analysis of In-Pile Phenomena in Advanced Test Reactor using Acoustic Telemetry

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Vivek [Idaho National Lab. (INL), Idaho Falls, ID (United States). Dept. of Human Factors, Controls, and Statistics; Smith, James A. [Idaho National Lab. (INL), Idaho Falls, ID (United States). Dept. of Fuel Performance and Design; Jewell, James Keith [Idaho National Lab. (INL), Idaho Falls, ID (United States). Dept. of Fuel Performance and Design

    2015-02-01

    The interior of a nuclear reactor presents a particularly harsh and challenging environment for both sensors and telemetry due to high temperatures and high fluxes of energetic and ionizing particles among the radioactive decay products. A number of research programs are developing acoustic-based sensing approach to take advantage of the acoustic transmission properties of reactor cores. Idaho National Laboratory has installed vibroacoustic receivers on and around the Advanced Test Reactor (ATR) containment vessel to take advantage of acoustically telemetered sensors such as thermoacoustic (TAC) transducers. The installation represents the first step in developing an acoustic telemetry infrastructure. This paper presents the theory of TAC, application of installed vibroacoustic receivers in monitoring the in-pile phenomena inside the ATR, and preliminary data processing results.

  19. ECOLOGY. Aquatic animal telemetry: A panoramic window into the underwater world.

    Science.gov (United States)

    Hussey, Nigel E; Kessel, Steven T; Aarestrup, Kim; Cooke, Steven J; Cowley, Paul D; Fisk, Aaron T; Harcourt, Robert G; Holland, Kim N; Iverson, Sara J; Kocik, John F; Mills Flemming, Joanna E; Whoriskey, Fred G

    2015-06-12

    The distribution and interactions of aquatic organisms across space and time structure our marine, freshwater, and estuarine ecosystems. Over the past decade, technological advances in telemetry have transformed our ability to observe aquatic animal behavior and movement. These advances are now providing unprecedented ecological insights by connecting animal movements with measures of their physiology and environment. These developments are revolutionizing the scope and scale of questions that can be asked about the causes and consequences of movement and are redefining how we view and manage individuals, populations, and entire ecosystems. The next advance in aquatic telemetry will be the development of a global collaborative effort to facilitate infrastructure and data sharing and management over scales not previously possible. Copyright © 2015, American Association for the Advancement of Science.

  20. Applied Multi-Mission Telemetry Processing and Display for Operations, Integration, Training, Playback and Event Reconstruction

    Science.gov (United States)

    Pomerantz, Marc; Nguyen, Viet; Lee, Daren; Lim, Christopher; Huynh, Tom

    2015-01-01

    Conveying spacecraft health and status information to mission engineering personnel during various mission phases, including mission operations, is a requirement to achieve a successful mission. For NASA/JPL spacecraft, that often means displaying hundreds of telemetry channels from a variety of sensors and components emitting data at rates varying from 1hz-100hz (and faster) in a way that allows the operations team to quickly evaluate the health of the vehicle, identify any off-nominal states and resolve any issues. In this paper we will discuss the system design, requirements and use cases of three telemetry processing and visualization systems recently developed and deployed by our team for NASA's Low Density Supersonic Decelerator (LDSD) test vehicle, NASA's Soil Moisture Active/Passive (SMAP) orbiter, and JPL's Sampling Lab Universal Robotic Manipulator (SLURM) test bed.

  1. Development of telemetry for the agility flight test of a radio controlled fighter model

    Science.gov (United States)

    Gallagher, Michael J.

    1992-03-01

    Advanced design tools, control devices, and supermaneuverability concepts provide innovative solutions to traditional aircraft design trade-offs. Emerging technologies enable improved agility throughout the performance envelope. Unmanned Air Vehicles provide an excellent platform for dynamic measurements and agility research. A 1/8-scaled F-16A ducted-fan radio-controlled aircraft was instrumented with a telemetry system to acquire angle of attack, sideslip angle, control surface deflection, throttle position, and airspeed data. A portable ground station was built to record and visually present real-time telemetry data. Flight tests will be conducted to acquire baseline high angle-of-attack performance measurements, and follow-on research will evaluate agility improvements with varied control configurations.

  2. Telemetry Metrics: Monitoring Data Quality in the Spacecraft Ground Data System

    Science.gov (United States)

    OBrien, Robin A.

    2006-01-01

    During the launch of Mars Odyssey, ground data system (GDS) engineers experienced a glitch in the ground data system that caused us to re-evaluate how we looked at spacecraft telemetry, particularly during the spacecraft development period and for critical spacecraft events in flight. Spacecraft telemetry told the subsystem and instrument engineers about the health and status of the spacecraft, but there was surprisingly little information about how well the ground data system was doing in getting information from the spacecraft to the engineers.The problem for the Mars Odyssey launch was with a single channel not updating as often as expected. Spacecraft engineers considered calling off the Launch but eventually decided that this particular channel did not provide information that was crucial for launch. It was only after the post launch acquisition of the Odyssey signal that ground data system engineers heard there had been a concern about the channel....

  3. Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft

    Science.gov (United States)

    Rizvi, Farheen

    2013-01-01

    A report describes a model that estimates the orientation of the backup reaction wheel using the reaction wheel spin rates telemetry from a spacecraft. Attitude control via the reaction wheel assembly (RWA) onboard a spacecraft uses three reaction wheels (one wheel per axis) and a backup to accommodate any wheel degradation throughout the course of the mission. The spacecraft dynamics prediction depends upon the correct knowledge of the reaction wheel orientations. Thus, it is vital to determine the actual orientation of the reaction wheels such that the correct spacecraft dynamics can be predicted. The conservation of angular momentum is used to estimate the orientation of the backup reaction wheel from the prime and backup reaction wheel spin rates data. The method is applied in estimating the orientation of the backup wheel onboard the Cassini spacecraft. The flight telemetry from the March 2011 prime and backup RWA swap activity on Cassini is used to obtain the best estimate for the backup reaction wheel orientation.

  4. Monitoring and Analysis of In-Pile Phenomena in Advanced Test Reactor using Acoustic Telemetry

    International Nuclear Information System (INIS)

    Agarwal, Vivek; Smith, James A.; Jewell, James Keith

    2015-01-01

    The interior of a nuclear reactor presents a particularly harsh and challenging environment for both sensors and telemetry due to high temperatures and high fluxes of energetic and ionizing particles among the radioactive decay products. A number of research programs are developing acoustic-based sensing approach to take advantage of the acoustic transmission properties of reactor cores. Idaho National Laboratory has installed vibroacoustic receivers on and around the Advanced Test Reactor (ATR) containment vessel to take advantage of acoustically telemetered sensors such as thermoacoustic (TAC) transducers. The installation represents the first step in developing an acoustic telemetry infrastructure. This paper presents the theory of TAC, application of installed vibroacoustic receivers in monitoring the in-pile phenomena inside the ATR, and preliminary data processing results.

  5. Integrating acoustic telemetry into mark-recapture models to improve the precision of apparent survival and abundance estimates.

    Science.gov (United States)

    Dudgeon, Christine L; Pollock, Kenneth H; Braccini, J Matias; Semmens, Jayson M; Barnett, Adam

    2015-07-01

    Capture-mark-recapture models are useful tools for estimating demographic parameters but often result in low precision when recapture rates are low. Low recapture rates are typical in many study systems including fishing-based studies. Incorporating auxiliary data into the models can improve precision and in some cases enable parameter estimation. Here, we present a novel application of acoustic telemetry for the estimation of apparent survival and abundance within capture-mark-recapture analysis using open population models. Our case study is based on simultaneously collecting longline fishing and acoustic telemetry data for a large mobile apex predator, the broadnose sevengill shark (Notorhynchus cepedianus), at a coastal site in Tasmania, Australia. Cormack-Jolly-Seber models showed that longline data alone had very low recapture rates while acoustic telemetry data for the same time period resulted in at least tenfold higher recapture rates. The apparent survival estimates were similar for the two datasets but the acoustic telemetry data showed much greater precision and enabled apparent survival parameter estimation for one dataset, which was inestimable using fishing data alone. Combined acoustic telemetry and longline data were incorporated into Jolly-Seber models using a Monte Carlo simulation approach. Abundance estimates were comparable to those with longline data only; however, the inclusion of acoustic telemetry data increased precision in the estimates. We conclude that acoustic telemetry is a useful tool for incorporating in capture-mark-recapture studies in the marine environment. Future studies should consider the application of acoustic telemetry within this framework when setting up the study design and sampling program.

  6. Telemetry Physical Activity Monitoring in Minipig’s Model of Huntington’s Disease

    Czech Academy of Sciences Publication Activity Database

    Pokorný, M.; Juhás, Štefan; Juhásová, Jana; Klíma, Jiří; Motlík, Jan; Klempíř, J.; Havlík, J.

    2015-01-01

    Roč. 78, Suppl 2 (2015), s. 39-42 ISSN 1210-7859. [Conference on Animal Models for neurodegenerative Diseases /3./. Liblice, 08.11.2015-10.11.2015] R&D Projects: GA MŠk ED2.1.00/03.0124; GA MŠk(CZ) 7F14308 Institutional support: RVO:67985904 Keywords : Huntington´s disease * minipig * telemetry Subject RIV: FH - Neurology Impact factor: 0.209, year: 2015

  7. A critical examination of indices of dynamic interaction for wildlife telemetry studies.

    Science.gov (United States)

    Long, Jed A; Nelson, Trisalyn A; Webb, Stephen L; Gee, Kenneth L

    2014-09-01

    Wildlife scientists continue to be interested in studying ways to quantify how the movements of animals are interdependent - dynamic interaction. While a number of applied studies of dynamic interaction exist, little is known about the comparative effectiveness and applicability of available methods used for quantifying interactions between animals. We highlight the formulation, implementation and interpretation of a suite of eight currently available indices of dynamic interaction. Point- and path-based approaches are contrasted to demonstrate differences between methods and underlying assumptions on telemetry data. Correlated and biased correlated random walks were simulated at a range of sampling resolutions to generate scenarios with dynamic interaction present and absent. We evaluate the effectiveness of each index at identifying different types of interactive behaviour at each sampling resolution. Each index is then applied to an empirical telemetry data set of three white-tailed deer (Odocoileus virginianus) dyads. Results from the simulated data show that three indices of dynamic interaction reliant on statistical testing procedures are susceptible to Type I error, which increases at fine sampling resolutions. In the white-tailed deer examples, a recently developed index for quantifying local-level cohesive movement behaviour (the di index) provides revealing information on the presence of infrequent and varying interactions in space and time. Point-based approaches implemented with finely sampled telemetry data overestimate the presence of interactions (Type I errors). Indices producing only a single global statistic (7 of the 8 indices) are unable to quantify infrequent and varying interactions through time. The quantification of infrequent and variable interactive behaviour has important implications for the spread of disease and the prevalence of social behaviour in wildlife. Guidelines are presented to inform researchers wishing to study dynamic

  8. Telemetry Standards, RCC Standard 106-17, Annex A.1, Pulse Amplitude Modulation Standards

    Science.gov (United States)

    2017-07-01

    Standard 106-17 Annex A.1, July 2017 A.1-iii Acronyms dB decibel FM frequency modulation IF intermediate frequency PAM pulse amplitude...standard defines the recommended pulse train structure and design characteristics for the implementation of pulse amplitude modulation (PAM) telemetry...between transitions in the PAM pulse train shall be limited by whichever is the narrower of the following: a. One-half of the 3-dB frequency of the

  9. An Evidence-Based Approach to Reducing Cardiac Telemetry Alarm Fatigue.

    Science.gov (United States)

    Srinivasa, Ekta; Mankoo, Jaspreet; Kerr, Charles

    2017-08-01

    It is estimated that between 80% and 99% of alarms in the clinical areas are in actionable alarms (Gross, Dahl, & Nielson). Alarm management is one of the Joint Commission's National Patient Safety Goals (2014) because sentinel events have directly been linked to the devices generating these alarms. At an acute care facility in Boston, a multidisciplinary team consisting of Nursing, Biomedical Engineers, Patient Safety and Providers was formed to conduct a pilot study on the state of telemetry alarms on a surgical floor. An evidence-based approach was taken utilizing Philips Real-time data exporter alarms tracking software to capture all telemetry alarms during a 43-day time span. Likewise, noise meters were placed near telemetry alarm speakers to track decibel levels within the aforementioned timeframe for 21 days. Analysis of the data showed that clinically insignificant Premature Ventricular Contractions (PVC) alarms accounted for more than 40% of all alarms in the unit within the time span, while also contributing to an average noise level of 58.49 dB. In response to the data, the interdisciplinary team approved to permanently default the settings for PAIR PVC, MULTIFORM PVC, and RUN PVC alarms to off. The results showed a 54% decrease in the rate of alarms per bed per day, and an average noise reduction of 2.3 dB between the two selected noise measurement areas. Organizing a multidisciplinary team provides an effective framework toward analyzing and addressing cardiac telemetry alarm fatigue. Looking at quantitative datasets for clinical care areas through various lenses helps identify opportunities for improvement in regards to highlighting alarms that are not actionable. Pilot changes to alarm parameters can be tested for their environmental impact in the care area. © 2017 Sigma Theta Tau International.

  10. Pennsylvania's proposed continuous emission monitoring system data telemetry requirements for municipal, hospital and infectious waste incinerators

    International Nuclear Information System (INIS)

    Nazzaro, J.C.

    1988-01-01

    This paper reports on the Pennsylvania Department of Environmental Resources which has established minimum plan approval, criteria which require certain affected sources to provide the Department with access to continuous emission monitoring (CEM) data via telephone line computer link or other approved means of transfer. The Department has specified formats for logging of CEM data to computer media, a general data telemetry access protocol, floppy disk reporting formats and hardcopy reporting formats

  11. Methodological validation of an existing telemetry system for QT evaluation in conscious guinea pigs.

    Science.gov (United States)

    Shiotani, Motohiro; Harada, Takuma; Abe, Junko; Hamada, Yoshimasa; Horii, Ikuo

    2007-01-01

    Guinea pigs are suitable for in vivo QT assessment of newly discovered drugs at the pre-clinical stage because of the ease with which these animals can be handled, the lower amount of compound required for testing, and the similarity of the ion channels between the guinea pig heart and the human. Our purpose was to provide detailed methodological information on an existing telemetry recording system for use in evaluating QT interval prolongation in guinea pigs. Hartley guinea pigs weighing 400-700 g were used to investigate the appropriate configuration of electrodes to record defined T-waves and the influence of the surgical implantation of a transmitter on the QT interval, as well as to determine the appropriate formula for QT correction. In addition, the validity of using telemetry-monitored guinea pigs was tested by using compounds with (positive references) or without (vehicles) a QT-prolonging effect. A lead with the negative pole placed between the scapulas and the positive pole positioned close to the sternum was found to be the most appropriate to obtain well-defined T-waves. The period for recovery from transmitter implantation was estimated to be at least 1 week. The best-fit formula for our telemetry guinea pig model was a modified Bazett's formula. QTc was prolonged significantly in guinea pigs given positive references, and the QTc was unaffected when the animals were given vehicles. We believe that the information provided herein will be a quite helpful guide for researchers to evaluate the QT interval reliably and reproducibly in this telemetry guinea pig model.

  12. 106-17 Telemetry Standards Recorder Data Packet Format Standard Chapter 11

    Science.gov (United States)

    2017-07-01

    PAT program association table PCM pulse code modulation Telemetry Standards, IRIG Standard 106-17 Chapter 11, July 2017 11-viii PCR program clock ...packet header, a packet body , and a packet trailer, and an optional part if enabled, a packet secondary header. A packet will always conform to the...Standard 106-17 Chapter 11, July 2017 11-3 SECONDARY HEADER CHECKSUM CHANNEL-SPECIFIC DATA Packet Body INTRA-PACKET TIME STAMP 1 INTRA-PACKET DATA

  13. Fiber Optic Telemetry System for LLL High-Voltage Test Stand

    International Nuclear Information System (INIS)

    Richter, J.P.

    1977-01-01

    This paper describes the Fiber Optic Telemetry System designed to operate in the hostile particle and electromagnetic radiation environment of the High Voltage Test Stand. It discusses system criteria, components, packaging, and performance. In all tests to date, the system exceeds its design goals with very comfortable margins. It is well advanced into the fabrication stages with all crucial components tested and only straightforward TTL (Transistor Transistor Logic) circuitry to be completed

  14. Architecture Study on Telemetry Coverage for Immediate Post-Separation Phase

    Science.gov (United States)

    Cheung, Kar-Ming; Lee, Charles H.; Kellogg, Kent H.; Stocklin, Frank J.; Zillig, David J.; Fielhauer, Karl B.

    2008-01-01

    This paper presents the preliminary results of an architecture study that provides continuous telemetry coverage for NASA missions for immediate post-separation phase. This study is a collaboration effort between Jet Propulsion Laboratory (JPL), Goddard Space Flight Center (GSFC), and Applied Physics Laboratory (APL). After launch when the spacecraft separated from the upper stage, the spacecraft typically executes a number of mission-critical operations prior to the deployment of solar panels and the activation of the primary communication subsystem. JPL, GSFC, and APL have similar design principle statements that require continuous coverage of mission-critical telemetry during the immediate post-separation phase. To conform to these design principles, an architecture that consists of a separate spacecraft transmitter and a robust communication network capable of tracking the spacecraft signals is needed.This paper presents the preliminary results of an architecture study that provides continuous telemetry coverage for NASA missions for immediate post-separation phase. This study is a collaboration effort between Jet Propulsion Laboratory (JPL), Goddard Space Flight Center (GSFC), and Applied Physics Laboratory (APL). After launch when the spacecraft separated from the upper stage, the spacecraft typically executes a number of mission-critical operations prior to the deployment of solar panels and the activation of the primary communication subsystem. JPL, GSFC, and APL have similar design principle statements that require continuous coverage of mission-critical telemetry during the immediate post-separation phase. To conform to these design principles, an architecture that consists of a separate spacecraft transmitter and a robust communication network capable of tracking the spacecraft signals is needed. The main results of this study are as follows: 1) At low altitude (applications. In this paper we present the detailed coverage analysis of Earth-based and

  15. Graphene for future electronics

    International Nuclear Information System (INIS)

    Pasanen, Pirjo; Voutilainen, Martti; Helle, Meri; Song Xuefeng; Hakonen, Pertti J

    2012-01-01

    We discuss some aspects of how graphene could be used in mainstream electronic devices. The main focus is on signal processing applications in high-volume, industrially manufactured battery-powered devices, e.g. mobile phones and laptop computers, but we will also discuss applicability to other components like interconnects, wireless communication antennae and camera sensors, as well as novel types of signal processing devices, based on the unique physical properties of graphene.

  16. High Speed Wireless Signal Generation and Demodulation

    DEFF Research Database (Denmark)

    Caballero Jambrina, Antonio; Sambaraju, Rakesh; Zibar, Darko

    We present the experimental demonstration of high speed wireless generation, up to 40 Gb/s, in the 75-110 GHz wireless band. All-optical OFDM and photonic up-conversion are used for generation and single side-band modulation with digital coherent detection for demodulation....

  17. The Invention of the Wireless Communication Engine

    NARCIS (Netherlands)

    van der Kooij, B.J.G.

    2017-01-01

    Wireless technology, taken for granted today, was once an innovative wonder that would forever change how the world communicates. Developed by Guglielmo Marconi in the latter half of the nineteenth century, wireless telegraphy combined advancements made by Samuel Morse, William Cooke, Charles

  18. Home and School Technology: Wired versus Wireless.

    Science.gov (United States)

    Van Horn, Royal

    2001-01-01

    Presents results of informal research on smart homes and appliances, structured home wiring, whole-house audio/video distribution, hybrid cable, and wireless networks. Computer network wiring is tricky to install unless all-in-one jacketed cable is used. Wireless phones help installers avoid pre-wiring problems in homes and schools. (MLH)

  19. A guide to wireless networking by light

    Science.gov (United States)

    Haas, Harald; Chen, Cheng; O'Brien, Dominic

    2017-09-01

    The lack of wireless spectrum in the radio frequency bands has led to a rapid growth in research in wireless networking using light, known as LiFi (light fidelity). In this paper an overview of the subsystems, challenges and techniques required to achieve this is presented.

  20. Enabling technologies for wireless e-business

    CERN Document Server

    Kou, Weidong

    2006-01-01

    Provides a coverage of the technologies needed to make wireless e-business effective. This book offers an introduction for both self-study and taught e-business classes or commercial training in e-business and wireless technologies. It explains both industry standards and relevant academic research.