WorldWideScience

Sample records for wire strike assessment

  1. The assessment of lethal propeller strike injuries in sea mammals.

    Science.gov (United States)

    Byard, Roger W; Winskog, Calle; Machado, Aaron; Boardman, Wayne

    2012-04-01

    Assessment of injuries in marine mammals may be required to help authorities determine whether human activity was involved. Three cases of marine animal deaths involving propeller blade strikes are reported to demonstrate characteristic features of such cases and diagnostic difficulties that may occur. Case 1: A juvenile New Zealand fur seal (Arctocephalus forsteri) suffered two parallel linear incised wounds of the flank and died following small intestinal herniation. Case 2: An Indo-Pacific bottlenose dolphin neonate (Tursiops aduncus) died from a deeply incised wound of the left side of the head with shattering of the skull and laceration of the underlying brain.Case 3: An adult female Indo-Pacific bottlenose dolphin (T. aduncus) died from two parallel chop wounds to the torso with opening of the thoracic and abdominal cavities with fractures of the ribs and vertebrae. Given that some animals may recover, and that the carcasses of those that are killed may simply not be found or reported, it is impossible to provide an estimate of the incidence of this type of injury amongst wild sea mammals. In cases that do come to forensic attention accurate evaluation of the type of injury may potentially have great medicolegal significance. Post-mortem putrefaction and post-mortem feeding by other sea animals may complicate assessments. Copyright © 2012 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  2. Assessment of SFR Wire Wrap Simulation Uncertainties

    Energy Technology Data Exchange (ETDEWEB)

    Delchini, Marc-Olivier G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Reactor and Nuclear Systems Division; Popov, Emilian L. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Reactor and Nuclear Systems Division; Pointer, William David [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Reactor and Nuclear Systems Division; Swiler, Laura P. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-09-30

    Predictive modeling and simulation of nuclear reactor performance and fuel are challenging due to the large number of coupled physical phenomena that must be addressed. Models that will be used for design or operational decisions must be analyzed for uncertainty to ascertain impacts to safety or performance. Rigorous, structured uncertainty analyses are performed by characterizing the model’s input uncertainties and then propagating the uncertainties through the model to estimate output uncertainty. This project is part of the ongoing effort to assess modeling uncertainty in Nek5000 simulations of flow configurations relevant to the advanced reactor applications of the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. Three geometries are under investigation in these preliminary assessments: a 3-D pipe, a 3-D 7-pin bundle, and a single pin from the Thermal-Hydraulic Out-of-Reactor Safety (THORS) facility. Initial efforts have focused on gaining an understanding of Nek5000 modeling options and integrating Nek5000 with Dakota. These tasks are being accomplished by demonstrating the use of Dakota to assess parametric uncertainties in a simple pipe flow problem. This problem is used to optimize performance of the uncertainty quantification strategy and to estimate computational requirements for assessments of complex geometries. A sensitivity analysis to three turbulent models was conducted for a turbulent flow in a single wire wrapped pin (THOR) geometry. Section 2 briefly describes the software tools used in this study and provides appropriate references. Section 3 presents the coupling interface between Dakota and a computational fluid dynamic (CFD) code (Nek5000 or STARCCM+), with details on the workflow, the scripts used for setting up the run, and the scripts used for post-processing the output files. In Section 4, the meshing methods used to generate the THORS and 7-pin bundle meshes are explained. Sections 5, 6 and 7 present numerical results

  3. Pre/post-strike atmospheric assessment system (PAAS)

    International Nuclear Information System (INIS)

    Peglow, S. G.; Molitoris, J. D.

    1997-01-01

    The Pre/Post-Strike Atmospheric Assessment System was proposed to show the importance of local meteorological conditions in the vicinity of a site suspected of storing or producing toxic agents and demonstrate a technology to measure these conditions, specifically wind fields. The ability to predict the collateral effects resulting from an attack on a facility containing hazardous materials is crucial to conducting effective military operations. Our study approach utilized a combination of field measurements with dispersion modeling to better understand which variables in terrain and weather were most important to collateral damage predictions. To develop the PAAS wind-sensing technology, we utilized a combination of emergent and available technology from micro-Doppler and highly coherent laser systems. The method used for wind sensing is to probe the atmosphere with a highly coherent laser beam. As the beam probes, light is back-scattered from particles entrained in the air to the lidar transceiver and detected by the instrument. Any motion of the aerosols with a component along the beam axis leads to a Doppler shift of the received light. Scanning in a conical fashion about the zenith results in a more accurate and two-dimensional measurement of the wind velocity. The major milestones in the benchtop system development were to verify the design by demonstrating the technique in the laboratory, then scale the design down to a size consistent with a demonstrator unit which could be built to take data in the field. The micro-Doppler heterodyne system we developed determines absolute motion by optically mixing a reference beam with the return signal and has shown motion sensitivity to better than 1 cm/s. This report describes the rationale, technical approach and laboratory testing undertaken to demonstrate the feasibility and utility of a system to provide local meteorological data and predict atmospheric particulate motion. The work described herein was funded by

  4. A rapid assessment of species-specific bird strike risk at the Kotoka ...

    African Journals Online (AJOL)

    A rapid assessment of species-specific bird strike risk at the Kotoka International Airport in Accra, Ghana. ... We conclude that wildlife management to avert the risk of bird strikes could be successfully achieved by adopting both proactive and reactive measures to reduce the presence of problem species at the aerodrome.

  5. Assessment of performing an MST strike in Tank 21H

    Energy Technology Data Exchange (ETDEWEB)

    Poirier, Michael R.

    2014-09-29

    Previous Savannah River National Laboratory (SRNL) tank mixing studies performed for the Small Column Ion Exchange (SCIX) project have shown that 3 Submersible Mixer Pumps (SMPs) installed in Tank 41 are sufficient to support actinide removal by MST sorption as well as subsequent resuspension and removal of settled solids. Savannah River Remediation (SRR) is pursuing MST addition into Tank 21 as part of the Large Tank Strike (LTS) project. The preliminary scope for LTS involves the use of three standard slurry pumps (installed in N, SE, and SW risers) in a Type IV tank. Due to the differences in tank size, internal interferences, and pump design, a separate mixing evaluation is required to determine if the proposed configuration will allow for MST suspension and strontium and actinide sorption. The author performed the analysis by reviewing drawings for Tank 21 [W231023] and determining the required cleaning radius or zone of influence for the pumps. This requirement was compared with previous pilot-scale MST suspension data collected for SCIX that determined the cleaning radius, or zone of influence, as a function of pump operating parameters. The author also reviewed a previous Tank 50 mixing analysis that examined the ability of standard slurry pumps to suspend sludge particles. Based on a review of the pilot-scale SCIX mixing tests and Tank 50 pump operating experience, three standard slurry pumps should be able to suspend sludge and MST to effectively sorb strontium and actinides onto the MST. Using the SCIX data requires an assumption about the impact of cooling coils on slurry pump mixing. The basis for this assumption is described in this report. Using the Tank 50 operating experience shows three standard slurry pumps should be able to suspend solids if the shear strength of the settled solids is less than 160 Pa. Because Tank 21 does not contain cooling coils, the shear strength could be larger.

  6. Wildlife strike risk assessment in several Italian airports: lessons from BRI and a new methodology implementation.

    Directory of Open Access Journals (Sweden)

    Cecilia Soldatini

    Full Text Available The presence of wildlife in airport areas poses substantial hazards to aviation. Wildlife aircraft collisions (hereafter wildlife strikes cause losses in terms of human lives and direct monetary losses for the aviation industry. In recent years, wildlife strikes have increased in parallel with air traffic increase and species habituation to anthropic areas. In this paper, we used an ecological approach to wildlife strike risk assessment to eight Italian international airports. The main achievement is a site-specific analysis that avoids flattening wildlife strike events on a large scale while maintaining comparable airport risk assessments. This second version of the Birdstrike Risk Index (BRI2 is a sensitive tool that provides different time scale results allowing appropriate management planning. The methodology applied has been developed in accordance with the Italian Civil Aviation Authority, which recognizes it as a national standard implemented in the advisory circular ENAC APT-01B.

  7. Wire system aging assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Fantoni, P.F.; Nordlund, A.

    2006-04-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report describes a method for wire system condition monitoring, developed at the Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. LIRA is composed of a signal generator, a signal analyser and a simulator that can be used to simulate several failure/degradation scenarios and assess the accuracy and sensitivity of the LIRA system. Chapter 5 of this report describes an complementary approach based on positron measurement techniques, used widely in defect physics due to the high sensitivity to micro defects, in particular open volume defects. This report describes in details these methodologies, the results of field experiments and the proposed future work. (au)

  8. Wire system aging assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. [Institutt for energiteknikk (Norway); Nordlund, A. [Chalmers Univ. of Technology (Sweden)

    2006-04-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report describes a method for wire system condition monitoring, developed at the Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. LIRA is composed of a signal generator, a signal analyser and a simulator that can be used to simulate several failure/degradation scenarios and assess the accuracy and sensitivity of the LIRA system. Chapter 5 of this report describes an complementary approach based on positron measurement techniques, used widely in defect physics due to the high sensitivity to micro defects, in particular open volume defects. This report describes in details these methodologies, the results of field experiments and the proposed future work. (au)

  9. Wire system ageing assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Ekelund, M; Gedde, U.W. (Royal Institute of Technology (KTH). Fibre and Polymer Technology, School of Chemical Science and Engineering, Stockholm (Sweden)); Fantoni, P.F. (Institute for Energy Technology (IFE), Halden (Norway))

    2011-05-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. In this report 3 techniques for cable global ageing assessment were tested and evaluated. The EAB technique is a destructive, local technique that is often used as a reference for other methods. The indenter is a local, in-situ mechanical technique that is currently quite often used in NPPs. LIRA is an electrical method, full line, in-situ. LIRA correlated quite well with EAB and both tend to flatten when the ageing time reaches 40 years. The only cable type that was difficult to assess for all the 3 methods was the medium type in air environment. These tests considered only thermal ageing, up to 50 years and should be completed by considering also gamma irradiation ageing. (Author)

  10. Wire system ageing assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Ekelund, M; Gedde, U.W.; Fantoni, P.F.

    2011-05-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. In this report 3 techniques for cable global ageing assessment were tested and evaluated. The EAB technique is a destructive, local technique that is often used as a reference for other methods. The indenter is a local, in-situ mechanical technique that is currently quite often used in NPPs. LIRA is an electrical method, full line, in-situ. LIRA correlated quite well with EAB and both tend to flatten when the ageing time reaches 40 years. The only cable type that was difficult to assess for all the 3 methods was the medium type in air environment. These tests considered only thermal ageing, up to 50 years and should be completed by considering also gamma irradiation ageing. (Author)

  11. Assessing the MR compatibility of dental retainer wires at 7 Tesla.

    Science.gov (United States)

    Wezel, Joep; Kooij, Bert Jan; Webb, Andrew G

    2014-10-01

    To determine the MR compatibility of common dental retainer wires at 7 Tesla in terms of potential RF heating and magnetic susceptibility effects. Electromagnetic simulations and experimental results were compared for dental retainer wires placed in tissue-mimicking phantoms. Simulations were then performed for a human model with wire in place. Finally, image quality was assessed for different scanning protocols and wires. Simulations and experimental data in phantoms agreed well, with the length of the wire correlating to maximum heating in phantoms being approximately 47 mm. Even in this case, no substantial heating occurs when scanning within the specific absorption rate (SAR) guidelines for the head. Image distortions from the most ferromagnetic dental wire were not significant for any brain region. Dental retainer wires appear to be MR compatible at 7 Tesla. Copyright © 2013 Wiley Periodicals, Inc.

  12. Printed Wiring Board Cleaner Technologies Substitutes Assessment: Making Holes Conductive

    Science.gov (United States)

    This document presents comparative risk, competitiveness, and resource requirements on technologies for performing the “making holes conductive” function during printed wiring board manufacturing.

  13. Lightning Often Strikes Twice

    Science.gov (United States)

    2005-01-01

    Contrary to popular misconception, lightning often strikes the same place twice. Certain conditions are just ripe for a bolt of electricity to come zapping down; and a lightning strike is powerful enough to do a lot of damage wherever it hits. NASA created the Accurate Location of Lightning Strikes technology to determine the ground strike point of lightning and prevent electrical damage in the immediate vicinity of the Space Shuttle launch pads at Kennedy Space Center. The area surrounding the launch pads is enmeshed in a network of electrical wires and components, and electronic equipment is highly susceptible to lightning strike damage. The accurate knowledge of the striking point is important so that crews can determine which equipment or system needs to be retested following a strike. Accurate to within a few yards, this technology can locate a lightning strike in the perimeter of the launch pad. As an added bonus, the engineers, then knowing where the lightning struck, can adjust the variables that may be attracting the lightning, to create a zone that will be less susceptible to future strikes.

  14. Wire system ageing assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. (Institute for Energy Technology (IFE) (Norway))

    2009-07-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains the results of experiments performed in collaboration with Tecnatom SA, Spain, to compare several cable condition monitoring techniques including LIRA (LIne Resonance Analysis) (au)

  15. Wire system ageing assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Fantoni, P.F.

    2009-07-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains the results of experiments performed in collaboration with Tecnatom SA, Spain, to compare several cable condition monitoring techniques including LIRA (LIne Resonance Analysis) (au)

  16. Wire system aging assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. [Institutt for energiteknikk, IFE (Norway)

    2007-04-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains some test results of a method for wire system condition monitoring, developed at the Halden Reactor Project, called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. (au)

  17. Fabrication and assessment of a thin flexible surface coating made of pristine graphene for lightning strike protection

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, B. [Department of Mechanical Engineering, Wichita State University, 1845 Fairmount St., Wichita, KS 67260-0133 (United States); Soltani, S.A. [Department of Aerospace Engineering, Wichita State University, 1845 Fairmount St., Wichita, KS 67260-0133 (United States); Le, L.N. [Department of Mechanical Engineering, Wichita State University, 1845 Fairmount St., Wichita, KS 67260-0133 (United States); Asmatulu, R., E-mail: ramazan.asmatulu@wichita.edu [Department of Mechanical Engineering, Wichita State University, 1845 Fairmount St., Wichita, KS 67260-0133 (United States)

    2017-02-15

    A thin flexible coating made of pristine graphene was fabricated and applied on the surface of a commercial carbon fiber epoxy prepreg laminate to protect it against the lightning strike. To assess the coating’s effectiveness, the coated laminate was subjected to the simulated lightning strike as well as the electromagnetic interference shielding effectiveness (EMI SE) testing. It was observed that the damaged area and volume in the coated laminate were reduced by 94% and 96%, respectively, as compared to the laminate without the coating. Moreover, the coated laminate had an average EMI SE of 51 dB over 100–2000 MHz range, 55 dB over 8–12 GHz range, and 60 dB over 12–18 GHz range marking 22%, 44%, and 49% improvement in EMI SE for each frequency range, respectively. The results indicate a great potential for the developed coating to protect the commercially available prepreg composites against the lightning strike.

  18. Life cycle assessment of the application of nanoclays in wire coating

    Science.gov (United States)

    Tellaetxe, A.; Blázquez, M.; Arteche, A.; Egizabal, A.; Ermini, V.; Rose, J.; Chaurand, P.; Unzueta, I.

    2012-09-01

    A life cycle assessment (LCA) is carried out to compare nanoclay-reinforced polymer wire coatings with conventional ones. While the conventional wire coatings contain standard halogen free retardants, in reinforced coatings, montmorillonite (nanoclay) is incorporated into electric cable linings as a rheological agent for an increased resistance to fire. In addition, a reduced load of standard halogen free retardants is obtained. The synergistic effect of the montmorillonite on traditional flame retardant additives (by the formation of a three-dimensional char network) can lead to a revolution in wire production. The application of nanoclays contributes also to anti-dripping effect and flexibility increase [1]. Some producers have already started commercializing wire with nanotechnology-based coating; in the short term the use of nanoclay in wire coating production will probably reach a significant market share replacing traditional formulations. The main aim of this study is to compare the environmental impacts along the life cycle of a traditional wire coating (mineral flame retardants like ATH or MDH in a polymer matrix) with the nanoclay-reinforced wire coating, where the montmorillonite replaces a low percentage of the mineral flame retardant. The system boundaries of the study include the following unit processes: nanoclay production, thermoplastic material and mineral flame retardants production, cable coating manufacturing by extrusion and different end of life scenarios (recycling, incineration and landfill disposal). Whereas nanoreinforced composites have shown and increased fire retardance, the addition of nanomaterials seems to have no significant relevance in the environmental assessment. However, the lack of nano-specific characterization factors for nanomaterials and emission rates associated to the different life cycle stages -mainly in the extrusion and use phase, where accidental combustions can take place- still remains a challenge for realistic

  19. Life cycle assessment of the application of nanoclays in wire coating

    International Nuclear Information System (INIS)

    Tellaetxe, A; Blázquez, M; Unzueta, I; Arteche, A; Egizabal, A; Ermini, V; Rose, J; Chaurand, P

    2012-01-01

    A life cycle assessment (LCA) is carried out to compare nanoclay-reinforced polymer wire coatings with conventional ones. While the conventional wire coatings contain standard halogen free retardants, in reinforced coatings, montmorillonite (nanoclay) is incorporated into electric cable linings as a rheological agent for an increased resistance to fire. In addition, a reduced load of standard halogen free retardants is obtained. The synergistic effect of the montmorillonite on traditional flame retardant additives (by the formation of a three-dimensional char network) can lead to a revolution in wire production. The application of nanoclays contributes also to anti-dripping effect and flexibility increase. Some producers have already started commercializing wire with nanotechnology-based coating; in the short term the use of nanoclay in wire coating production will probably reach a significant market share replacing traditional formulations. The main aim of this study is to compare the environmental impacts along the life cycle of a traditional wire coating (mineral flame retardants like ATH or MDH in a polymer matrix) with the nanoclay-reinforced wire coating, where the montmorillonite replaces a low percentage of the mineral flame retardant. The system boundaries of the study include the following unit processes: nanoclay production, thermoplastic material and mineral flame retardants production, cable coating manufacturing by extrusion and different end of life scenarios (recycling, incineration and landfill disposal). Whereas nanoreinforced composites have shown and increased fire retardance, the addition of nanomaterials seems to have no significant relevance in the environmental assessment. However, the lack of nano-specific characterization factors for nanomaterials and emission rates associated to the different life cycle stages -mainly in the extrusion and use phase, where accidental combustions can take place- still remains a challenge for realistic life

  20. An integrated approach to the probabilistic assessments of aircraft strikes and structural mode of damages to nuclear power plants

    International Nuclear Information System (INIS)

    Godbout, P.; Brais, A.

    1975-01-01

    The possibilities of an aircraft striking a Canadian nuclear power plant in the vicinity of an airport and of inducing structural failure modes have been evaluated. This evaluation, together with other studies, may enhance decisions in the development of general criteria for the siting of reactors near airports. The study made use, for assessment, of the probabilistic approach and made judicious applications of the finite Canadian, French, German, American and English resources that were available. The tools, techniques and methods used for achieving the above, form what may be called an integrated approach. This method of approach requires that the study be made in six consecutive steps as follows: the qualitative evaluation of having an aircraft strike on a site situated near an airport with the use of the logic model technique; the statistical data gathering on aircraft movements and accidents; evaluating the probability distribution and calculating the basic event probabilities; evaluating the probability of an aircraft strike and the application of the sensitivity approach; generating the probability density distribution versus strike impact energy, that is, the evaluation of the energy envelope; and the probabilistic evaluation of structural failure mode inducements

  1. Environmental Assessment: Bird Strike Risk Reduction at Laughlin Air Force Base, Texas

    Science.gov (United States)

    2008-01-01

    Although cyfluthrin is used in many applications, both indoor and for agricultural crop protection, there is no EPA registration for outdoor noncropland...Sterling 1972, Barrett 1968). Carbaryl is severely toxic to predatory mites , but less toxic to phytophagous mites (Bartlett 1968). LAFB Strike Risk...and feces. Workers occupationally exposed by inhalation to carbaryl dust excreted 74% of the inhaled dose in the urine in the form of a breakdown

  2. Assessment of Proton Deflectometry for Exploding Wire Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Beg, Farhat Nadeem [University of California San Diego

    2013-09-25

    This project provides the first demonstration of the application of proton deflectometry for the diagnosis of electromagnetic field topology and current-carrying regions in Z-pinch plasma experiments. Over the course of this project several milestones were achieved. High-energy proton beam generation was demonstrated on the short-pulse high-intensity Leopard laser, (10 Joules in ~350 femtoseconds, and the proton beam generation was shown to be reproducible. Next, protons were used to probe the electromagnetic field structure of short circuit loads in order to benchmark the two numerical codes, the resistive-magnetohydrodynamics (MHD) code, Gorgon, and the hybrid particle-in-cell code, LSP for the interpretation of results. Lastly, the proton deflectometry technique was used to map the magnetic field structure of pulsed-power-driven plasma loads including wires and supersonic jets formed with metallic foils. Good agreement between the modeling and experiments has been obtained. The demonstrated technique holds great promise to significantly improve the understanding of current flow and electromagnetic field topology in pulsed power driven high energy density plasmas. Proton probing with a high intensity laser was for the first time implemented in the presence of the harsh debris and x-ray producing z-pinch environment driven by a mega-ampere-scale pulsed-power machine. The intellectual merit of the program was that it investigated strongly driven MHD systems and the influence of magnetic field topology on plasma evolution in pulsed power driven plasmas. The experimental program involved intense field-matter interaction in the generation of the proton probe, as well as the generation of plasma subjected to 1 MegaGauss scale magnetic fields. The computational aspect included two well-documented codes, in combination for the first time to provide accurate interpretation of the experimental results. The broader impact included the support of 2 graduate students, one at

  3. Comparative assessment between eyelet wiring and direct interdental wiring for achieving intermaxillary fixation: a prospective randomized clinical study.

    Science.gov (United States)

    Rai, Anshul; Datarkar, Abhay; Borle, Rajeev; Rai, Monika

    2012-08-01

    The intention of this study was to compare the efficacy of eyelet wiring and direct interdental (Gilmer) wiring for achieving intermaxillary fixation (IMF). This study was a prospective randomized clinical trial. The study sample was derived from the population of patients who underwent IMF at the Department of Oral and Maxillofacial Surgery, Sharad Pawar Dental College, Wardha, India, between October 2008 and September 2010. The time required for placement and removal (in minutes) was compared between the eyelet wiring and direct interdental wiring techniques. Postoperative stability after achieving IMF was analyzed in the 2 groups. The plaque accumulation in both groups was evaluated using the Turesky-Gilmore-Glickman modification of the Quigley-Hein plaque index. Complications in the form of soft tissue injury, glove puncture, and trauma to the operator's finger were also recorded. Statistical analysis was performed with SPSS statistical software for Windows, version 8.0 (SPSS, Chicago, IL) using the χ(2) test and Student t test. The mean working time for placement and removal of eyelet wiring (group I) was 18.00 minutes and 9.67 minutes, respectively. For direct interdental wiring (group II), it was 30.50 minutes and 23.12 minutes, respectively. The mean plaque index values were 1.78 and 2.54 for groups I and II, respectively, which signifies a higher plaque deposition in group II. No occlusal disturbance was seen in either group. The incidences of glove perforation, soft tissue trauma, and trauma to the operator's finger were higher in group II. Eyelet wiring is preferable to direct interdental wiring as evidenced by fewer complications, and requires a shorter operating time in patients with minimally displaced fractures. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Fish Passage Assessment of an Advanced Hydropower Turbine and Conventional Turbine Using Blade-Strike Modeling

    Directory of Open Access Journals (Sweden)

    Zhiqun Deng

    2011-01-01

    Full Text Available Hydropower is the largest renewable energy source in the world. However, in the Columbia and Snake River basins, several species of Pacific salmon and steelhead have been listed for protection under the Endangered Species Act due to significant declines of fish population. Dam operators and design engineers are thus faced with the task of making hydroelectric facilities more fish friendly through changes in hydro-turbine design and operation. Public Utility District No. 2 of Grant County, Washington, applied for relicensing from the U.S. Federal Energy Regulatory Commission to replace the 10 turbines at Wanapum Dam with advanced hydropower turbines that were designed to increase power generation and improve fish passage conditions. We applied both deterministic and stochastic blade-strike models to compare fish passage performance of the newly installed advanced turbine to an existing turbine. Modeled probabilities were compared to the results of a large-scale live-fish survival study and a Sensor Fish study under the same operational parameters. Overall, injury rates predicted by the deterministic model were higher than experimental rates of injury, while those predicted by the stochastic model were in close agreement with experimental results. Fish orientation at the time of entry into the plane of the leading edges of the turbine runner blades was an important factor contributing to uncertainty in modeled results. The advanced design turbine had slightly higher modeled injury rates than the existing turbine design; however, no statistical evidence suggested significant differences in blade-strike injuries between the two turbines, thus the hypothesis that direct fish survival rate through the advanced hydropower turbine is equal to or higher than that for fish passing through the conventional turbine could not be rejected.

  5. Assessment of wire and tube penetration theories using a 218PoOx cluster aerosol

    International Nuclear Information System (INIS)

    Ramamurthi, Mukund; Strydom, Rian; Hopke, P.K.

    1990-01-01

    Diffusion samplers are commonly used for the measurement of aerosol size distributions (d p p : 0.5-3 nm, such as those associated with radon decay products. The methods have relied upon the Cheng-Yeh wire screen penetration theory [Cheng, Y.S. and Yeh, H.C. (1980) J. Aerosol Sci. ll, 313.] that has been verified for particle sizes d p >3.5-4 nm. The validity of the theory in the ultrafine cluster size range has been assumed. In this study, a well-defined 218 PoO x cluster aerosol D avg =0.078±0.0003 cm 2 s -1 (d p ≅ 0.6 nm) was generated for an assessment of the wire screen penetration theory for two low mesh number wire screens. The results indicated good agreement with the theory, within the domain of its underlying assumptions. In addition, a theoretical expression developed by Ingham [Ingham, D.B. (1975) J. Aerosol Sci. 6, 125.] for uniform flow tube penetration was investigated using the cluster aerosol for its applicability in the estimation of diffusional losses in the entrance of a tube. (author)

  6. Mangroves, hurricanes, and lightning strikes: Assessment of Hurricane Andrew suggests an interaction across two differing scales of disturbance

    Science.gov (United States)

    Smith, Thomas J.; Robblee, Michael B.; Wanless, Harold R.; Doyle, Thomas W.

    1994-01-01

    The track of Hurricane Andrew carried it across one of the most extensive mangrove for ests in the New World. Although it is well known that hurricanes affect mangrove forests, surprisingly little quantitative information exists concerning hurricane impact on forest structure, succession, species composition, and dynamics of mangrove-dependent fauna or on rates of eco-system recovery (see Craighead and Gilbert 1962, Roth 1992, Smith 1992, Smith and Duke 1987, Stoddart 1969).After Hurricane Andrew's passage across south Florida, we assessed the environmental damage to the natural resources of the Everglades and Biscayne National Parks. Quantitative data collected during subsequent field trips (October 1992 to July 1993) are also provided. We present measurements of initial tree mortality by species and size class, estimates of delayed (or continuing) tree mortality, and observations of geomorphological changes along the coast and in the forests that could influence the course of forest recovery. We discuss a potential interaction across two differing scales of disturbance within mangrove forest systems: hurricanes and lightning strikes.

  7. METHODS OF MEASURING THE EFFECTS OF LIGHTNING BY SIMULATING ITS STRIKES WITH THE INTERVAL ASSESSMENT OF THE RESULTS OF MEASUREMENTS

    Directory of Open Access Journals (Sweden)

    P. V. Kriksin

    2017-01-01

    Full Text Available The article presents the results of the development of new methods aimed at more accurate interval estimate of the experimental values of voltages on grounding devices of substations and circuits in the control cables, that occur when lightning strikes to lightning rods; the abovementioned estimate made it possible to increase the accuracy of the results of the study of lightning noise by 28 %. A more accurate value of interval estimation were achieved by developing a measurement model that takes into account, along with the measured values, different measurement errors and includes the special processing of the measurement results. As a result, the interval of finding the true value of the sought voltage is determined with an accuracy of 95 %. The methods can be applied to the IK-1 and IKP-1 measurement complexes, consisting in the aperiodic pulse generator, the generator of high-frequency pulses and selective voltmeters, respectively. To evaluate the effectiveness of the developed methods series of experimental voltage assessments of grounding devices of ten active high-voltage substation have been fulfilled in accordance with the developed methods and traditional techniques. The evaluation results confirmed the possibility of finding the true values of voltage over a wide range, that ought to be considered in the process of technical diagnostics of lightning protection of substations when the analysis of the measurement results and the development of measures to reduce the effects of lightning are being fulfilled. Also, a comparative analysis of the results of measurements made in accordance with the developed methods and traditional techniques has demonstrated that the true value of the sought voltage may exceed the measured value at an average of 28 %, that ought to be considered in the further analysis of the parameters of lightning protection at the facility and in the development of corrective actions. The developed methods have been

  8. Basic Wiring.

    Science.gov (United States)

    Kaltwasser, Stan; And Others

    This module is the first in a series of three wiring publications; it serves as the foundation for students enrolled in a wiring program. It is a prerequisite to either "Residential Wiring" or "Commercial and Industrial Wiring." The module contains 16 instructional units that cover the following topics: occupational…

  9. Towards plant wires

    OpenAIRE

    Adamatzky, Andrew

    2014-01-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self...

  10. Preparing for radiological assessments in the event of a tornado strike at Argonne National Lab.-East

    International Nuclear Information System (INIS)

    Goodkind, M.E.; Klimczak, C.A.; Munyon, W.J.

    1993-01-01

    Argonne National Laboratory-East (ANL) is a Department of Energy (DOE)-owned, contractor-operated national laboratory located 22 miles southwest of downtown Chicago on a wooded, 1700-acre site. The principal nuclear facilities at ANL include a large fast neutron source (Intense Pulse Neutron Source) in which high-energy protons strike a uranium target to produce neutrons for research studies; 60 Co irradiation sources; chemical and metallurgical plutonium laboratories, some of which are currently being decommissioned; several large hot cell facilities designed for work with multicurie quantities of actinide elements and irradiated reactor fuel materials; a few small research reactors currently in different phases of being decommissioned; and a variety of research laboratories handling many different sources in various chemical and physical forms. The hazards analysis for the ANL site shows that tornado strikes are a serious threat. The site has been struck twice in the past 20 yr, receiving only minor building damage and no release of radioactivity to the environment. Although radioactive materials in general are handled in areas that provide good tornado protection, ANL is prepared to address the problems that would occur should there be a loss of control of radioactive materials due to severe building damage

  11. Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots.

    Science.gov (United States)

    Dolci, Gabriel Schmidt; Spohr, Ana Maria; Zimmer, Eduardo Rigon; Marchioro, Ernani Menezes

    2013-01-01

    The purpose of this study was to evaluate the dimensions and surface characteristics of orthodontic wires and bracket slots of different commercial brands. Thirty metallic brackets (0.022 x 0.028-in and 0.022 x 0.030-in) were divided into three groups: DYN/3M group = Dyna-Lock, 3M/Unitek (stainless steel, or SS); STD/MO group = Slim Morelli (SS); and Ni-Free/MO group = Slim Morelli (Ni-Free). The stainless steel wires (0.019 x 0.025-in) were divided into two groups: MO group = Morelli; and 3M group = 3M/Unitek. The bracket and wire measurements were done by two methods: (a) Surface Electron Microscopy (SEM), and (b) Profile Projection. The surface analysis was done qualitatively, based on SEM images and/or by a rugosimeter. The quantitative results were analyzed by ANOVA with Tukey's test (p wires, groups showed statistically different mean heights. It was concluded that wires and brackets slots can present altered dimensions, which might directly and unintentionally affect the planned tooth movement.

  12. Assessment of the dimensions and surface characteristics of orthodontic wires and bracket slots

    Directory of Open Access Journals (Sweden)

    Gabriel Schmidt Dolci

    2013-04-01

    Full Text Available OBJECTIVE: The purpose of this study was to evaluate the dimensions and surface characteristics of orthodontic wires and bracket slots of different commercial brands. METHODS: Thirty metallic brackets (0.022 x 0.028-in and 0.022 x 0.030-in were divided in three groups: DYN/3M group = Dyna-Lock, 3M/Unitek (stainless steel, or SS; STD/MO group = Slim Morelli (SS; and Ni-Free/MO group = Slim Morelli (Ni-Free. The stainless steel wires (0.019 x 0.025in were divided into two groups: MO group = Morelli; and 3M group = 3M/Unitek. The bracket and wire measurements were done by two methods: (a Surface Electron Microscopy (SEM, and (b Profile projection. The surface analysis was done qualitatively, based on SEM images and/or by a rugosimeter. The quantitative results were analyzed by ANOVA with Tukey's test (p < 0.05 and Student's t test. RESULTS: A significant difference in the dimensions of slots was observed, and the NiFree/MO group showed the greatest changes when compared to the other groups. The analysis of surface topography of the brackets indicated greater homogeneity of the metallic matrix for DYN/3M and STD/MO groups. As for the dimensions of the wires, groups showed statistically different mean heights. CONCLUSIONS: It was concluded that wires and brackets slots can present altered dimensions, which might directly and unintentionally affect the planned tooth movement.

  13. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  14. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  15. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  16. Options with Extreme Strikes

    Directory of Open Access Journals (Sweden)

    Lingjiong Zhu

    2015-07-01

    Full Text Available In this short paper, we study the asymptotics for the price of call options for very large strikes and put options for very small strikes. The stock price is assumed to follow the Black–Scholes models. We analyze European, Asian, American, Parisian and perpetual options and conclude that the tail asymptotics for these option types fall into four scenarios.

  17. Should doctors strike?

    Science.gov (United States)

    Park, John J; Murray, Scott A

    2014-05-01

    Last year in June, British doctors went on strike for the first time since 1975. Amidst a global economic downturn and with many health systems struggling with reduced finances, around the world the issue of public health workers going on strike is a very real one. Almost all doctors will agree that we should always follow the law, but often the law is unclear or does not cover a particular case. Here we must appeal to ethical discussion. The General Medical Council, in its key guidance document for practising doctors, Good Medical Practice, claims that 'Good doctors make the care of their patients their first concern'. Is this true? And if so, how is this relevant to the issue of striking? One year on since the events, we carefully reflect and argue whether it was right for doctors to pursue strike action, and call for greater discussion of ethical issues such as the recent strikes, particularly among younger members of the profession.

  18. Combined approach to damaged wire ropes life-time assessment based on NDT results and rope mechanics

    Science.gov (United States)

    Vorontsov, A.; Volokhovsky, V.; Slesarev, D.

    2011-07-01

    Principles of strength assessment and life-time prediction of deteriorated wire ropes based on magnetic NDT technique are presented. The measured loss of metallic cross-section area due to abrasion, corrosion etc. and local wire breaks are treated as input data for mechanical model of rope structure. The rope is interpreted as a system with two degrees of freedom that enables to calculate the strains and stresses in each wire when the rope is subjected to tension, torsion and bending. Stress safety factor is considered as a generalized parameter that specifies the rope degradation and may be used for predicting the instant lifetimes during the rope operating history. The rope discard criterion refers to residual life-time calculated with respect to minimal allowable strength factor. Examples of integrity analysis of mine hoisting rope and jib crane rope under tension-bending fatigue loading are demonstrated. The residual strength estimates give the rope inspector further information that helps to make a valid decision on testing policy.

  19. Combined approach to damaged wire ropes life-time assessment based on NDT results and rope mechanics

    International Nuclear Information System (INIS)

    Vorontsov, A; Volokhovsky, V; Slesarev, D

    2011-01-01

    Principles of strength assessment and life-time prediction of deteriorated wire ropes based on magnetic NDT technique are presented. The measured loss of metallic cross-section area due to abrasion, corrosion etc. and local wire breaks are treated as input data for mechanical model of rope structure. The rope is interpreted as a system with two degrees of freedom that enables to calculate the strains and stresses in each wire when the rope is subjected to tension, torsion and bending. Stress safety factor is considered as a generalized parameter that specifies the rope degradation and may be used for predicting the instant lifetimes during the rope operating history. The rope discard criterion refers to residual life-time calculated with respect to minimal allowable strength factor. Examples of integrity analysis of mine hoisting rope and jib crane rope under tension-bending fatigue loading are demonstrated. The residual strength estimates give the rope inspector further information that helps to make a valid decision on testing policy.

  20. Improving work conditions through strike: Examination of nurses' attitudes through perceptions of two physician strikes in Israel.

    Science.gov (United States)

    Gafni-Lachter, Liat; Admi, Hanna; Eilon, Yael; Lachter, Jesse

    2017-01-01

    Strikes are means to influence policies related to working conditions, yet raise ethical dilemmas for healthcare workers. Nurse strikes have become more prominent around the world. To assess the change in Israeli nurses' attitudes towards strikes in light of two physician strikes that have preceded a nursing strike. An anonymous survey was administered once in 2000 (N = 106) and again in 2011 (n = 175) following 110 days of a physician strike, to assess nurses' attitudes towards the strike and resulting ethical issues. A statistically significant change (p working conditions related to professional and public health agendas.

  1. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  2. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  4. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  5. Towards plant wires.

    Science.gov (United States)

    Adamatzky, Andrew

    2014-08-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self-growing wetware circuits and devices, and integration of plant-based electronic components into future and emergent bio-hybrid systems. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Predictive Factors in Conflict: Assessing the Likelihood of a Preemptive Strike by Israel on Iran Using a Computer Model

    Science.gov (United States)

    2013-03-01

    Proliferation Treaty OSINT Open Source Intelligence SAFF Safing, Arming, Fuzing, Firing SIAM Situational Influence Assessment Module SME Subject...assisting with the framework for this venture during our influence modeling class. The thoughtful insight provided by the group when we first worked... framework for modeling conflict in general, the near-term objective is to produce a model that provides a simplistic input and a single output to

  7. A right to strike?

    Science.gov (United States)

    Jennings, K; Western, G

    1997-07-01

    During 1995, there was a major shift in the United Kingdom in the debate of whether it is right for nurses to strike. The Royal College of Nursing, the former advocate of a non-industrial action policy, moved towards the UNISON position that industrial action is ethical in some circumstances, as well as the necessary thing to do. The authors, both nurses and UNISON officials, look at the reasons for this change and why UNISON's historical position sees industrial action as an effective weapon in defending services, as well as wages and jobs. It can be right to strike.

  8. Wire Roughness Assessment of 0.016'' × 0.022'' the Technique Lingual Orthodontics.

    Science.gov (United States)

    Facchini, Fátima Mm; Filho, Mario Vedovello; Vedovello, Silvia As; Cotrim, Flávio A; Cotrim-Ferreira, Andrຟa; Tubel, Carlos Am

    2017-04-01

    To evaluate the difference in surface roughness of stainless steel archwires of different commercial brands used in lingual orthodontics. Precontoured arches measuring 0.016'' × 0.022'' were selected of the following brands: Tecnident, Adenta, G&H, Highland Metals Inc., Ormco, Incognito, and Ebraces. Quantitative evaluation of the surface roughness of archwires was performed by means of an atomic force microscope in contact mode. Three surface readouts were taken of each sample, analyzing areas of 20 × 20 μm. Each scan of the samples produced a readout of 512 lines, generating three-dimensional images of the wires. The analysis of variance statistical test was applied to prove significant variables (p > 0.05), with H 0 being rejected and H 1 accepted. The Incognito brand showed the lowest surface roughness. The archwires of brands Adenta, Tecnident, Highland, and Ormco showed similar values among them, and all close to these obtained by the Incognito brand. The archwires of the Ebraces brand showed the highest surface roughness, with values being close to those of the G&H Brand. There was a statistical difference in surface roughness of orthodontic archwires among the brands studied. Companies should pay attention to the quality control of their materials, as these may directly affect the quality of orthodontic treatment.

  9. Algab õppus "Saber Strike"

    Index Scriptorium Estoniae

    2014-01-01

    Täna algab Eestis, Lätis ja Leedus Ameerika Ühendriikide Euroopa väekoondise õppus "Saber Strike", mille eesmärk on maaväeüksuste koostöö harjutamine. Õppusest võtab osa üle 2000 kaitseväelase Baltimaadest, USAst, Ühendkuningriigist, Taanist, Norrast, Soomest ja Saksamaalt. Eestist osaleb õppusel ligi 400 kaitseväelast

  10. Global strike hypersonic weapons

    Science.gov (United States)

    Lewis, Mark J.

    2017-11-01

    Beginning in the 1940's, the United States has pursued the development of hypersonic technologies, enabling atmospheric flight in excess of five times the speed of sound. Hypersonic flight has application to a range of military and civilian applications, including commercial transport, space access, and various weapons and sensing platforms. A number of flight tests of hypersonic vehicles have been conducted by countries around the world, including the United States, Russia, and China, that could lead the way to future hypersonic global strike weapon systems. These weapons would be especially effective at penetrating conventional defenses, and could pose a significant risk to national security.

  11. Impulse of a Kendo Strike

    Directory of Open Access Journals (Sweden)

    Masahiro Abe

    2012-06-01

    Full Text Available An expert swordsman struck a target with a kendo sword. The velocity and force of the strike were measured. The relationship between the strike velocity, impact force and effective mass of the sword was investigated. It was shown that the effective mass of the sword remains constant for typical strike velocities.

  12. Assessing the effects of manual dexterity and playing computer games on catheter-wire manipulation for inexperienced operators.

    Science.gov (United States)

    Alsafi, Z; Hameed, Y; Amin, P; Shamsad, S; Raja, U; Alsafi, A; Hamady, M S

    2017-09-01

    To investigate the effect of playing computer games and manual dexterity on catheter-wire manipulation in a mechanical aortic model. Medical student volunteers filled in a preprocedure questionnaire assessing their exposure to computer games. Their manual dexterity was measured using a smartphone game. They were then shown a video clip demonstrating renal artery cannulation and were asked to reproduce this. All attempts were timed. Two-tailed Student's t-test was used to compare continuous data, while Fisher's exact test was used for categorical data. Fifty students aged 18-22 years took part in the study. Forty-six completed the task at an average of 168 seconds (range 103-301 seconds). There was no significant difference in the dexterity score or time to cannulate the renal artery between male and female students. Students who played computer games for >10 hours per week had better dexterity scores than those who did not play computer games: 9.1 versus 10.2 seconds (p=0.0237). Four of 19 students who did not play computer games failed to complete the task, while all of those who played computer games regularly completed the task (p=0.0168). Playing computer games is associated with better manual dexterity and ability to complete a basic interventional radiology task for novices. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  13. Waste management of printed wiring boards: a life cycle assessment of the metals recycling chain from liberation through refining.

    Science.gov (United States)

    Xue, Mianqiang; Kendall, Alissa; Xu, Zhenming; Schoenung, Julie M

    2015-01-20

    Due to economic and societal reasons, informal activities including open burning, backyard recycling, and landfill are still the prevailing methods used for electronic waste treatment in developing countries. Great efforts have been made, especially in China, to promote formal approaches for electronic waste management by enacting laws, developing green recycling technologies, initiating pilot programs, etc. The formal recycling process can, however, engender environmental impact and resource consumption, although information on the environmental loads and resource consumption is currently limited. To quantitatively assess the environmental impact of the processes in a formal printed wiring board (PWB) recycling chain, life cycle assessment (LCA) was applied to a formal recycling chain that includes the steps from waste liberation through materials refining. The metal leaching in the refining stage was identified as a critical process, posing most of the environmental impact in the recycling chain. Global warming potential was the most significant environmental impact category after normalization and weighting, followed by fossil abiotic depletion potential, and marine aquatic eco-toxicity potential. Scenario modeling results showed that variations in the power source and chemical reagents consumption had the greatest influence on the environmental performance. The environmental impact from transportation used for PWB collection was also evaluated. The results were further compared to conventional primary metals production processes, highlighting the environmental benefit of metal recycling from waste PWBs. Optimizing the collection mode, increasing the precious metals recovery efficiency in the beneficiation stage and decreasing the chemical reagents consumption in the refining stage by effective materials liberation and separation are proposed as potential improvement strategies to make the recycling chain more environmentally friendly. The LCA results provide

  14. Precision Strike Annual Programs Review

    Science.gov (United States)

    2009-03-11

    Damage Area*• GPS / INS Navigation + SAL Terminal • Precise əm CEP • Low Probability of Collateral Damage • GPS Extends Glide Range to 10+km • Agile...Page 311 Mar 09 Unclassified Unclassified Viper Strike Lineage Viper Strike SAL Seeker Proof of Principle Demos I & II Hunter-Viper Strike Quick...Information Management • CCA - Clinger Cohen Act • RIT- Rapid Improvement Team • BMMP – Business Management Modernization Program • BTA/ERAM – Business

  15. Simulating the Risk of Bird Strikes

    NARCIS (Netherlands)

    Metz, I.C.; Ellerbroek, J.; Muhlhausen, Thorsten; Kügler, D.; Hoekstra, J.M.

    2017-01-01

    This paper presents a fast-time simulation environment for assessing the risk of bird strikes in aviation. An existing air traffic simulator was enhanced in order to simulate air and bird traffic simultaneously and to recognize collisions between birds and aircraft. Furthermore, a method was

  16. Life Cycle Assessment of Wire + Arc Additive Manufacturing compared to green sand casting and CNC milling in stainless steel

    NARCIS (Netherlands)

    Bekker, A.C.M.; Verlinden, J.C.

    2018-01-01

    Wire and Arc Additive Manufacturing (WAAM) is a metal 3D printing technique based on robotic welding. This technique yields potential in decreasing material consumption due to its high material efficiency and freedom of shape. Empirical measurements of WAAM, using a deposition rate of 1 kg/h, were

  17. Noncontextual Wirings

    Science.gov (United States)

    Amaral, Barbara; Cabello, Adán; Cunha, Marcelo Terra; Aolita, Leandro

    2018-03-01

    Contextuality is a fundamental feature of quantum theory necessary for certain models of quantum computation and communication. Serious steps have therefore been taken towards a formal framework for contextuality as an operational resource. However, the main ingredient of a resource theory—a concrete, explicit form of free operations of contextuality—was still missing. Here we provide such a component by introducing noncontextual wirings: a class of contextuality-free operations with a clear operational interpretation and a friendly parametrization. We characterize them completely for general black-box measurement devices with arbitrarily many inputs and outputs. As applications, we show that the relative entropy of contextuality is a contextuality monotone and that maximally contextual boxes that serve as contextuality bits exist for a broad class of scenarios. Our results complete a unified resource-theoretic framework for contextuality and Bell nonlocality.

  18. Striking a balance?

    DEFF Research Database (Denmark)

    Ibsen, Christian Lyhne; Mailand, Mikkel

    2011-01-01

    and electrical contracting industries of Denmark, Spain and the UK to assess this link. In line with prior research, the article finds that Danish agreements contribute significantly to flexicurity. Somewhat against conventional expectations, however, are findings in the UK and Spain. In the UK, agreements...

  19. Assessment of the wire-wrap models and improvement of the MATRA-LMR for subchannel blockage analysis

    Energy Technology Data Exchange (ETDEWEB)

    Ha, K. S.; Jeong, H. Y.; Chang, W. P.; Lee, Y. B

    2003-06-01

    The distributed resistance model has been newly implemented into MATRA-LMR to improve its prediction capability over the wire-wrap model for the flow blockage analysis in LMR. The code capability has been investigated using the experimental data observed in FFM(Fuel Failure Mock-up)-2A and 5B for the two typical flow conditions in a blocked channel. The predicted results by MATRA-LMR with the distributed resistance model have agreed well with the experimental data for the wire-wrapped subchannels. However, it has been suggested that the parameter n in the distributed resistance model needs to be calibrated accurately for the reasonable prediction of the temperature field under a low flow condition.

  20. Wave-to-wire Modelling of Wave Energy Converters : Critical Assessment, Developments and Applicability for Economical Optimisation

    DEFF Research Database (Denmark)

    Ferri, Francesco

    The idea to use the motion of a wavy sea surface to produce electricity was investigate in the seventies, in a time when the earliest wave energy converters were conceived and developed. But nowadays still none of the patented devices reached a commercial stage. Wave energy is a large, mostly...... this goal a reliable wave-to-wire (numerical) model is needed and a validation procedure based on experimental data sets have been used through the work....

  1. Continental United States Hurricane Strikes

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Continental U.S. Hurricane Strikes Poster is our most popular poster which is updated annually. The poster includes all hurricanes that affected the U.S. since...

  2. Upward streamers produced by a lightning strike to radio transmission towers

    Science.gov (United States)

    Krider, E. Philip; Wetmore, Ralph H.

    1987-01-01

    A lightning strike to the center of three 78-m radio transmission towers produced upward discharges with lengths of 40 and 79 m from each of the neighboring towers. This strike also caused a number of insulators on guy wires that supported the tower to flash over, and the locations of these points and the two-dimensional geometry of the discharge channels are projected onto a vertical plane that is centered on the tower.

  3. Stretched Wire Mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, Gordon; /SLAC

    2005-09-06

    Stretched wires are beginning to play an important role in the alignment of accelerators and synchrotron light sources. Stretched wires are proposed for the alignment of the 130 meter long LCLS undulator. Wire position technology has reached sub-micron resolution yet analyses of perturbations to wire straightness are hard to find. This paper considers possible deviations of stretched wire from the simple 2-dimensional catenary form.

  4. Vertical-axis rotations and deformation along the active strike-slip El Tigre Fault (Precordillera of San Juan, Argentina) assessed through palaeomagnetism and anisotropy of magnetic susceptibility

    Science.gov (United States)

    Fazzito, Sabrina Y.; Rapalini, Augusto E.; Cortés, José M.; Terrizzano, Carla M.

    2017-03-01

    Palaeomagnetic data from poorly consolidated to non-consolidated late Cenozoic sediments along the central segment of the active El Tigre Fault (Central-Western Precordillera of the San Juan Province, Argentina) demonstrate broad cumulative deformation up to 450 m from the fault trace and reveal clockwise and anticlockwise vertical-axis rotations of variable magnitude. This deformation has affected in different amounts Miocene to late Pleistocene samples and indicates a complex kinematic pattern. Several inherited linear structures in the shear zone that are oblique to the El Tigre Fault may have acted as block boundary faults. Displacement along these faults may have resulted in a complex pattern of rotations. The maximum magnitude of rotation is a function of the age of the sediments sampled, with largest values corresponding to middle Miocene-lower Pliocene deposits and minimum values obtained from late Pleistocene deposits. The kinematic study is complemented by low-field anisotropy of magnetic susceptibility data to show that the local strain regime suggests a N-S stretching direction, subparallel to the strike of the main fault.

  5. The HayWired Earthquake Scenario

    Science.gov (United States)

    Detweiler, Shane T.; Wein, Anne M.

    2017-04-24

    ForewordThe 1906 Great San Francisco earthquake (magnitude 7.8) and the 1989 Loma Prieta earthquake (magnitude 6.9) each motivated residents of the San Francisco Bay region to build countermeasures to earthquakes into the fabric of the region. Since Loma Prieta, bay-region communities, governments, and utilities have invested tens of billions of dollars in seismic upgrades and retrofits and replacements of older buildings and infrastructure. Innovation and state-of-the-art engineering, informed by science, including novel seismic-hazard assessments, have been applied to the challenge of increasing seismic resilience throughout the bay region. However, as long as people live and work in seismically vulnerable buildings or rely on seismically vulnerable transportation and utilities, more work remains to be done.With that in mind, the U.S. Geological Survey (USGS) and its partners developed the HayWired scenario as a tool to enable further actions that can change the outcome when the next major earthquake strikes. By illuminating the likely impacts to the present-day built environment, well-constructed scenarios can and have spurred officials and citizens to take steps that change the outcomes the scenario describes, whether used to guide more realistic response and recovery exercises or to launch mitigation measures that will reduce future risk.The HayWired scenario is the latest in a series of like-minded efforts to bring a special focus onto the impacts that could occur when the Hayward Fault again ruptures through the east side of the San Francisco Bay region as it last did in 1868. Cities in the east bay along the Richmond, Oakland, and Fremont corridor would be hit hardest by earthquake ground shaking, surface fault rupture, aftershocks, and fault afterslip, but the impacts would reach throughout the bay region and far beyond. The HayWired scenario name reflects our increased reliance on the Internet and telecommunications and also alludes to the

  6. The HayWired earthquake scenario

    Science.gov (United States)

    Detweiler, Shane T.; Wein, Anne M.

    2017-04-24

    ForewordThe 1906 Great San Francisco earthquake (magnitude 7.8) and the 1989 Loma Prieta earthquake (magnitude 6.9) each motivated residents of the San Francisco Bay region to build countermeasures to earthquakes into the fabric of the region. Since Loma Prieta, bay-region communities, governments, and utilities have invested tens of billions of dollars in seismic upgrades and retrofits and replacements of older buildings and infrastructure. Innovation and state-of-the-art engineering, informed by science, including novel seismic-hazard assessments, have been applied to the challenge of increasing seismic resilience throughout the bay region. However, as long as people live and work in seismically vulnerable buildings or rely on seismically vulnerable transportation and utilities, more work remains to be done.With that in mind, the U.S. Geological Survey (USGS) and its partners developed the HayWired scenario as a tool to enable further actions that can change the outcome when the next major earthquake strikes. By illuminating the likely impacts to the present-day built environment, well-constructed scenarios can and have spurred officials and citizens to take steps that change the outcomes the scenario describes, whether used to guide more realistic response and recovery exercises or to launch mitigation measures that will reduce future risk.The HayWired scenario is the latest in a series of like-minded efforts to bring a special focus onto the impacts that could occur when the Hayward Fault again ruptures through the east side of the San Francisco Bay region as it last did in 1868. Cities in the east bay along the Richmond, Oakland, and Fremont corridor would be hit hardest by earthquake ground shaking, surface fault rupture, aftershocks, and fault afterslip, but the impacts would reach throughout the bay region and far beyond. The HayWired scenario name reflects our increased reliance on the Internet and telecommunications and also alludes to the

  7. EDITORIAL: Dearing strikes again!

    Science.gov (United States)

    Dobson Honorary Editor, Ken

    1996-05-01

    recommendations which will need very careful and intelligent management if they are to be both workable and beneficial; unfortunately recent history tells us that the Government's agencies responsible for educational management are insensitive to the advice of practitioners and work to hidden political agendas based on prejudgement if not downright prejudice. The Report's recommendations certainly provide a challenge for post-16 physics, especially for A-level. It is to be hoped that the new structures and initiatives of the Institute of Physics will be able to play a full part in ensuring that changes are beneficial and workable. Firstly, Sir Ron wants A-levels to provide opportunities and contexts for the development of some general skills, identified as communication (both written and oral), numeracy and in information technology, with a less clear reference to an ability to work as part of a team. Challenge 1: find good contexts in physics for these - and a valid assessment system. Secondly, the curriculum should be broadened by a kind of two-phase approach to post-16 studies. Potential A-level students would spend a year studying as many as six Advanced Subsidiary level subjects, chosen from four main areas: science, maths and technology; modern languages; arts and humanities; `the way the community works' (business, economics, law, psychology etc). Each new-style AS would be the first half of an A-level course. The second phase would allow specialization into, say, three A-levels as at present, or to a combination of A and AS courses. Challenge 2: design a half course that makes sense, and is as useful to potential lawyers as to potential physicists. Thirdly, there should be an increase in the size of the A-level subject cores. Challenge 3: design such an extended core that is less boringly old-fashioned than the current one (not too difficult, that) and is capable of useful fission (see Challenge 2). This is a good opportunity to consider the nature of a `core' in physics

  8. [Physicians' strikes--ethical considerations].

    Science.gov (United States)

    Glick, Shimon; Schwarzfuchs, Dan

    2012-01-01

    Strikes in general represent a solution based on a form of coercion. Historically, the striker caused direct damage to his employer, who was responsible for the perceived unfair treatment of the employee. In the case of strikes in the public sector, the employer is generally not harmed, but innocent citizens suffer in order to pressure the government agencies, a questionable practice from an ethical viewpoint. Physicians' strikes have more serious ethical problems. They cause suffering and death to innocent citizens. They violate the ethical codes to which physicians have committed themselves as professionals, and they seriously impair the trust of the public in physicians. Better and more ethical ways to provide fair compensation for physicians must be employed, perhaps like those used for judges and members of the IDF.

  9. Risk Considerations of Bird Strikes to Space Launch Vehicles

    Science.gov (United States)

    Hales, Christy; Ring, Robert

    2016-01-01

    Within seconds after liftoff of the Space Shuttle during mission STS-114, a turkey vulture impacted the vehicle's external tank. The contact caused no apparent damage to the Shuttle, but the incident led NASA to consider the potential consequences of bird strikes during a Shuttle launch. The environment at Kennedy Space Center provides unique bird strike challenges due to the Merritt Island National Wildlife Refuge and the Atlantic Flyway bird migration routes. NASA is currently refining risk assessment estimates for the probability of bird strike to space launch vehicles. This paper presents an approach for analyzing the risks of bird strikes to space launch vehicles and presents an example. The migration routes, types of birds present, altitudes of those birds, exposed area of the launch vehicle, and its capability to withstand impacts affect the risk due to bird strike. A summary of significant risk contributors is discussed.

  10. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  11. Water Desalination with Wires

    NARCIS (Netherlands)

    Porada, S.; Sales, B.B.; Hamelers, H.V.M.; Biesheuvel, P.M.

    2012-01-01

    We show the significant potential of water desalination using a novel capacitive wire-based technology in which anode/cathode wire pairs are constructed from coating a thin porous carbon electrode layer on top of electrically conducting rods (or wires). By alternately dipping an array of electrode

  12. PS wire chamber

    CERN Document Server

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. Wavelet transform analysis of electromyography kung fu strikes data.

    Science.gov (United States)

    Neto, Osmar Pinto; Marzullo, Ana Carolina de Miranda

    2009-11-01

    In martial arts and contact sports strikes are performed at near maximum speeds. For that reason, electromyography (EMG) analysis of such movements is non-trivial. This paper has three main goals: firstly, to investigate the differences in the EMG activity of muscles during strikes performed with and without impacts; secondly, to assess the advantages of using Sum of Significant Power (SSP) values instead of root mean square (rms) values when analyzing EMG data; and lastly to introduce a new method of calculating median frequency values using wavelet transforms (WMDF). EMG data of the deltoid anterior (DA), triceps brachii (TB) and brachioradialis (BR) muscles were collected from eight Kung Fu practitioners during strikes performed with and without impacts. SSP results indicated significant higher muscle activity (p = 0.023) for the strikes with impact. WMDF results, on the other hand, indicated significant lower values (p = 0. 007) for the strikes with impact. SSP results presented higher sensitivity than rms to quantify important signal differences and, at the same time, presented lower inter-subject coefficient of variations. The result of increase in SSP values and decrease in WMDF may suggest better synchronization of motor units for the strikes with impact performed by the experienced Kung Fu practitioners. Key PointsThe results show higher muscle activity and lower electromyography median frequencies for strikes with impact compared to strikes without.SSP results presented higher sensitivity and lower inter-subject coefficient of variations than rms results.Kung Fu palm strikes with impact may present better motor units' synchronization than strikes without.

  14. Respecting the right to strike

    CERN Multimedia

    Staff Association

    2015-01-01

    Since two years the representatives of the employers in the ILO, a tripartite multilateral body responsible for guaranteeing the correct application of an international labour code, try to weaken the global work regulations. On the occasion of the Global Day of Action for the right to strike at the invitation of the Geneva community of Union action (Communauté genevoise d’action syndicale) and the Swiss Trade Union Association (Union syndicale suisse) around noon on Wednesday 18th February some fifty staff representatives of international organizations gathered on the place des Nations in Geneva to reaffirm the importance of this fundamental right, too often flouted. A delegation of the CERN Staff Association was also present. In a short speech, the Staff Association said that, while being one of the fundamental human rights, to be efficient the right to strike must be used intelligently. It must be implemented taking into account the sensitivities of the professional environment and r...

  15. A Randomized Prospective Comparison of Patient-Assessed Satisfaction and Clinical Outcomes with Radioactive Seed Localization versus Wire Localization.

    Science.gov (United States)

    Bloomquist, Erica V; Ajkay, Nicolas; Patil, Sujata; Collett, Abigail E; Frazier, Thomas G; Barrio, Andrea V

    2016-01-01

    Radioactive seed localization (RSL) has emerged as an alternative to wire localization (WL) in patients with nonpalpable breast cancer. Few studies have prospectively evaluated patient satisfaction and outcomes with RSL. We report the results of a randomized trial comparing RSL to WL in our community hospital. We prospectively enrolled 135 patients with nonpalpable breast cancer between 2011 and 2014. Patients were randomized to RSL or WL. Patients rated the pain and the convenience of the localization on a 5-point Likert scale. Characteristics and outcomes were compared between groups. Of 135 patients enrolled, 10 were excluded (benign pathology, palpable cancer, mastectomy, and previous ipsilateral cancer) resulting in 125 patients. Seventy patients (56%) were randomized to RSL and 55 (44%) to WL. Fewer patients in the RSL group reported moderate to severe pain during the localization procedure compared to the WL group (12% versus 26%, respectively, p = 0.058). The overall convenience of the procedure was rated as very good to excellent in 85% of RSL patients compared to 44% of WL patients (p patient satisfaction with RSL provides another incentive for surgeons to strongly consider RSL as an alternative to WL. © 2015 Wiley Periodicals, Inc.

  16. Macular damage following lightning strikes.

    Science.gov (United States)

    Augustin, A J; Koch, F; Böker, T

    1995-07-01

    Two men with recent history of lightining strike were referred to our hospital. Both patients complained of metamorphosia in one eye and reduced visual acuity. Funduscopy revealed target-like alterations at the fovea. Fluorescein angiography showed window defects of the central retinal pigment epithelium in both patients. One patient developed an anterior subcapsular cataract. If the eye is part of the current-circuit, the melanin granules of the iris, pigment epithelium, and choroid might act as a resistor. The resulting accumulation of heat may lead to damage of the surrounding tissues.

  17. Photovoltaic Wire, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  18. Photovoltaic Wire Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  19. Charpak hemispherical wire chamber

    CERN Document Server

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  20. 1998 wire development workshop proceedings

    International Nuclear Information System (INIS)

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development

  1. Women, transition and strikes in Serbia

    OpenAIRE

    Novaković, Nada G.

    2014-01-01

    The author, in a sociological way, describes and analyzes the concepts of transition, privatization and strikes in Serbia, particularly the place of women in it. It examines the most important economic and social causes and consequences of these phenomena. The main hypothesis is: women's strikes in the Serbian transition are less efficient than strikes and public protests of women in the developed world and the second Yugoslavia. A strike is a class conflict, in which the workers are fighting...

  2. 14 CFR 35.38 - Lightning strike.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Lightning strike. 35.38 Section 35.38... STANDARDS: PROPELLERS Tests and Inspections § 35.38 Lightning strike. The applicant must demonstrate, by... lightning strike without causing a major or hazardous propeller effect. The limit to which the propeller has...

  3. Environmental Assessment for Conventional Strike Missile Demonstration

    Science.gov (United States)

    2010-08-01

    E Loggerhead sea turtle Caretta caretta T Olive ridley sea turtle Lepidochelys oliveacea T Leatherback sea turtle Dermochelys coriacea E Notes...Sea Turtle Lapidochelys olivacea T, RS Leatherback Sea Turtle Dermochelys coriacea E, RS Hawksbill Sea Turtle Eretmochelys imbricata E, RS Birds

  4. Wire Array Photovoltaics

    Science.gov (United States)

    Turner-Evans, Dan

    Over the past five years, the cost of solar panels has dropped drastically and, in concert, the number of installed modules has risen exponentially. However, solar electricity is still more than twice as expensive as electricity from a natural gas plant. Fortunately, wire array solar cells have emerged as a promising technology for further lowering the cost of solar. Si wire array solar cells are formed with a unique, low cost growth method and use 100 times less material than conventional Si cells. The wires can be embedded in a transparent, flexible polymer to create a free-standing array that can be rolled up for easy installation in a variety of form factors. Furthermore, by incorporating multijunctions into the wire morphology, higher efficiencies can be achieved while taking advantage of the unique defect relaxation pathways afforded by the 3D wire geometry. The work in this thesis shepherded Si wires from undoped arrays to flexible, functional large area devices and laid the groundwork for multijunction wire array cells. Fabrication techniques were developed to turn intrinsic Si wires into full p-n junctions and the wires were passivated with a-Si:H and a-SiNx:H. Single wire devices yielded open circuit voltages of 600 mV and efficiencies of 9%. The arrays were then embedded in a polymer and contacted with a transparent, flexible, Ni nanoparticle and Ag nanowire top contact. The contact connected >99% of the wires in parallel and yielded flexible, substrate free solar cells featuring hundreds of thousands of wires. Building on the success of the Si wire arrays, GaP was epitaxially grown on the material to create heterostructures for photoelectrochemistry. These cells were limited by low absorption in the GaP due to its indirect bandgap, and poor current collection due to a diffusion length of only 80 nm. However, GaAsP on SiGe offers a superior combination of materials, and wire architectures based on these semiconductors were investigated for multijunction

  5. Automating wiring formboard design

    NARCIS (Netherlands)

    Van den Berg, T.

    2013-01-01

    Increase in aircraft wiring complexity call for manufacturing design improvements to reduce cost and lead-time. To achieve such improvements, a joint research project was performed by the Flight Performance and Propulsion (FPP) group and Fokker Elmo BV, the second largest aircraft wiring harness

  6. Strikes in Serbia since 2000 to 2005

    Directory of Open Access Journals (Sweden)

    Novaković Nada

    2005-01-01

    Full Text Available In this article author deals with main characteristics of strikes in Serbia within the period 2000–2005. Analysis starts with thesis that strike is open class conflict within class divided society. Therefore strike is radical form of trade union struggle for workers rights. Main questions in the analysis were: on social structure as a background of strikes, on organizations and trade unions included in it, on effects of strikes in Serbia in the given period. Main thesis of the article is that every power dislike strikes and is ready to do everything to diminish them. Main reason lies in the class nature of social conflict that underlie them. Main processes that underlie strike phenomena in Serbia since 2000. are the processes of originally capital accumulation. These bring about the formation of new capitalist class and proletariat of all professions. Author gives a brief analysis of privatization process, as well as of restructuring of public sector and deregulation of economy trying to show the role of all of it in origins of strikes. Main conclusion is that there are large number of strikes in all parts of society, that are well organized, with support of one or more trade unions. For these in power they are factor of obstacle on the way of successful transition. As for the reasons and outcomes these strikes are akin to the strikes at the beginning of 19th century.

  7. Third-party support for strike action.

    Science.gov (United States)

    Kelloway, E Kevin; Francis, Lori; Catano, Victor M; Dupré, Kathryne E

    2008-07-01

    Labor strikes are often seen as battles for public support. Members of the public are asked to show respect for a strike by refusing to cross the picket line or by joining strikers on the picket line. Such public support may affect the morale of strikers and influence the strike's duration. Despite the perceived importance of the public in labor disputes, members of third parties have not been considered in previous strike research. In 2 studies, the authors show that a new measure of third-party strike support is unidimensional and highly reliable. In both cases, union attitudes and perceptions of distributive justice were significant predictors of support for strike action. Those who are more supportive of unions in general and believe that the contract offered to the strikers was unfair were more likely to support the strike by engaging in such actions as conversing with strikers, writing letters, and refusing to cross the picket line.

  8. WAVELET TRANSFORM ANALYSIS OF ELECTROMYOGRAPHY KUNG FU STRIKES DATA

    Directory of Open Access Journals (Sweden)

    Ana Carolina de Miranda Marzullo

    2009-11-01

    Full Text Available In martial arts and contact sports strikes are performed at near maximum speeds. For that reason, electromyography (EMG analysis of such movements is non-trivial. This paper has three main goals: firstly, to investigate the differences in the EMG activity of muscles during strikes performed with and without impacts; secondly, to assess the advantages of using Sum of Significant Power (SSP values instead of root mean square (rms values when analyzing EMG data; and lastly to introduce a new method of calculating median frequency values using wavelet transforms (WMDF. EMG data of the deltoid anterior (DA, triceps brachii (TB and brachioradialis (BR muscles were collected from eight Kung Fu practitioners during strikes performed with and without impacts. SSP results indicated significant higher muscle activity (p = 0.023 for the strikes with impact. WMDF results, on the other hand, indicated significant lower values (p = 0. 007 for the strikes with impact. SSP results presented higher sensitivity than rms to quantify important signal differences and, at the same time, presented lower inter-subject coefficient of variations. The result of increase in SSP values and decrease in WMDF may suggest better synchronization of motor units for the strikes with impact performed by the experienced Kung Fu practitioners

  9. A Stochastic Analysis of the Transient Current Induced along the Thin Wire Scatterer Buried in a Lossy Medium

    Directory of Open Access Journals (Sweden)

    Silvestar Šesnić

    2016-01-01

    Full Text Available The paper deals with the stochastic collocation analysis of a time domain response of a straight thin wire scatterer buried in a lossy half-space. The wire is excited either by a plane wave transmitted through the air-ground interface or by an equivalent current source representing direct lightning strike pulse. Transient current induced at the center of the wire, governed by corresponding Pocklington integrodifferential equation, is determined analytically. This antenna configuration suffers from uncertainties in various parameters, such as ground properties, wire dimensions, and position. The statistical processing of the results yields additional information, thus enabling more accurate and efficient analysis of buried wire configurations.

  10. The Assessment Of The Structure And Properties Of High-Carbon Steel Wires After The Process Of Patenting With Induction Heating

    Directory of Open Access Journals (Sweden)

    Wiewiórowska S.

    2015-06-01

    Full Text Available One of the most important types of heat treatment that high-carbon steel wires are subjected to is the patenting treatment. This process is conducted with the aim of obtaining a fine-grained uniform pearlitic structure which will be susceptible to plastic deformation in drawing processes. Patenting involves two-stage heat treatment that includes heating the wire up to the temperature above Ac3 in a continuous heating furnace (in the temperature range of 850÷1050°C followed by a rapid cooling in a tank with a lead bath down to the temperature range of 450÷550°C. The patenting process is most significantly influenced by the chemistry of the steel being treated, as well as by the temperature and the rate of heating and cooling of the wire rod or wire being patented.

  11. Quality and Cost Assessment of Treatment with SiMg and NiCuMg Master Alloys vs Cored Wire in Production of Ductile Iron

    Directory of Open Access Journals (Sweden)

    E. Guzik

    2007-07-01

    Full Text Available The results of studies on the use of magnesium alloy in modern cored wire injection method for production of nodular and vermicular graphite cast irons were described. The injection of Mg cored wire length is a treatment method which can be used to process high sulphur cupola iron held in ladles or iron melted in an electric induction furnace. This paper describes the results of using a high-magnesium ferrosilicon alloy in cored wire (Mg recovery 47-70% for the production of vermicular and nodular graphite cast irons at Ścinawka Foundry, and for the production of nodular graphite iron at the following foundries: GZUT, KRAKODLEW, Centrozap - DEFKA, EE Zawiercie, WSK–Rzeszów, FWM PRZYSUCHA, HSW Stalowa Wola and PIOMA. The results of calculations and experiments have indicated the length of the cored wire to be injected basing on the initial sulfur content and weight of the treated melt. The results of numerous trials have shown that the magnesium cored wire process can produce high quality nodular and vermicular graphite irons under the specific industrial conditions of the above mentioned foundries. It has also been proved that in the manufacture of nodular graphite iron, the cost of the nodulariser in the form of elastic cored wire is lower than the cost of the FeSiMg or NiCuMg master alloys.

  12. Assessment of Abrasive Wear of Nanostructured WC-Co and Fe-Based Coatings Applied by HP-HVOF, Flame, and Wire Arc Spray

    Science.gov (United States)

    Lima, C. R. C.; Libardi, R.; Camargo, F.; Fals, H. C.; Ferraresi, V. A.

    2014-10-01

    Thermal spray processes have been widely used to minimize losses caused by wear mechanisms. Sprayed deposits using conventional wire and powder materials have been long solving tribological problems in engineering equipment. More recently, the option for new different technologies and consumables like nanostructured powder materials and nanocomposite cored wires have expanded the possibilities for technical solutions. Cored wire technology allows the use of compositions that cannot be drawn into wire form like carbides in metallic matrix and high-temperature materials, thus, intensifying the use of spraying processes with low operating cost to demanding wear and corrosion applications. The objective of this work was to study the mechanical characteristics and wear performance of coatings obtained by Flame, Wire Arc, and HVOF spraying using selected nanostructured WC10Co4Cr, WC12Co, and Fe-based 140 MXC powder and wire materials. Abrasive wear performance of the coatings was determinate following the ASTM G-65 standard. Based on the results, a higher abrasive wear resistance was found for the HVOF-sprayed WC10Co4Cr nanostructured coating.

  13. Does routine pressure wire assessment influence management strategy at coronary angiography for diagnosis of chest pain? The RIPCORD Study

    OpenAIRE

    Curzen, Nick; Rana, Omar; Nicholas, Zoe; Golledge, Peter; Zaman, Azfar; Oldroyd, Keith; Hanratty, Colm; Banning, Adrian; Wheatcroft, Stephen; Hobson, Alex; Chitkara, Kam; Hildick-Smith, David; McKenzie, Dan; Calver, Alison; Dimitrov, Borislav D.

    2014-01-01

    Background — The use of coronary angiography (CA) for diagnosis and management of chest pain (CP) has several flaws. The assessment of coronary artery disease using fractional flow reserve (FFR) is a well-validated technique for describing lesion-level ischemia and improves clinical outcome in the context of percutaneous coronary intervention. The impact of routine FFR at the time of diagnostic CA on patient management has not been determined.Method and Results — Two hundred patients with sta...

  14. Modeling and simulation of the fluid flow in wire electrochemical machining with rotating tool (wire ECM)

    Science.gov (United States)

    Klocke, F.; Herrig, T.; Zeis, M.; Klink, A.

    2017-10-01

    Combining the working principle of electrochemical machining (ECM) with a universal rotating tool, like a wire, could manage lots of challenges of the classical ECM sinking process. Such a wire-ECM process could be able to machine flexible and efficient 2.5-dimensional geometries like fir tree slots in turbine discs. Nowadays, established manufacturing technologies for slotting turbine discs are broaching and wire electrical discharge machining (wire EDM). Nevertheless, high requirements on surface integrity of turbine parts need cost intensive process development and - in case of wire-EDM - trim cuts to reduce the heat affected rim zone. Due to the process specific advantages, ECM is an attractive alternative manufacturing technology and is getting more and more relevant for sinking applications within the last few years. But ECM is also opposed with high costs for process development and complex electrolyte flow devices. In the past, few studies dealt with the development of a wire ECM process to meet these challenges. However, previous concepts of wire ECM were only suitable for micro machining applications. Due to insufficient flushing concepts the application of the process for machining macro geometries failed. Therefore, this paper presents the modeling and simulation of a new flushing approach for process assessment. The suitability of a rotating structured wire electrode in combination with an axial flushing for electrodes with high aspect ratios is investigated and discussed.

  15. Thermosonic wire bonding of IC devices using palladium wire

    International Nuclear Information System (INIS)

    Shze, J.H.; Poh, M.T.; Tan, R.M.

    1996-01-01

    The feasibility of replacing gold wire by palladium wire in thermosonic wire bonding of CMOS and bipolar devices are studied in terms of the manufacturability, physical, electrical and assembly performance. The results that palladium wire is a viable option for bonding the bipolar devices but not the CMOS devices

  16. Cryogenic Pressure Seal for Wires

    Science.gov (United States)

    Ciana, J. J.

    1984-01-01

    High-pressure-seal formed by forcing polyurethane into space surrounding wire or cable in special fitting. Wire or cable routed through fitting then through a tightly fitting cap. Wire insulation left intact. Cap filled with sealant and forced onto the fitting: this pushes sealant into fitting so it seals wire or cable in fitting as well as in cap.

  17. Does routine pressure wire assessment influence management strategy at coronary angiography for diagnosis of chest pain?: the RIPCORD study.

    Science.gov (United States)

    Curzen, Nick; Rana, Omar; Nicholas, Zoe; Golledge, Peter; Zaman, Azfar; Oldroyd, Keith; Hanratty, Colm; Banning, Adrian; Wheatcroft, Stephen; Hobson, Alex; Chitkara, Kam; Hildick-Smith, David; McKenzie, Dan; Calver, Alison; Dimitrov, Borislav D; Corbett, Simon

    2014-04-01

    The use of coronary angiography (CA) for diagnosis and management of chest pain (CP) has several flaws. The assessment of coronary artery disease using fractional flow reserve (FFR) is a well-validated technique for describing lesion-level ischemia and improves clinical outcome in the context of percutaneous coronary intervention. The impact of routine FFR at the time of diagnostic CA on patient management has not been determined. Two hundred patients with stable CP underwent CA for clinical indications. The supervising cardiologist (S.C.) made a management plan based on CA (optimal medical therapy alone, percutaneous coronary intervention, coronary artery bypass grafting, or more information required) and also recorded which stenoses were significant. An interventional cardiologist then measured FFR in all patent coronary arteries of stentable diameter (≥2.25 mm). S.C. was then asked to make a second management plan when FFR results were disclosed. Overall, after disclosure of FFR data, management plan based on CA alone was changed in 26% of patients, and the number and localization of functional stenoses changed in 32%. Specifically, of 72 cases in which optimal medical therapy was recommended after CA, 9 (13%) were actually referred for revascularization with FFR data. By contrast, of 89 cases in whom management plan was optimal medical therapy based on FFR, revascularization would have been recommended in 25 (28%) based on CA. Routine measurement of FFR at CA has important influence both on which coronary arteries have significant stenoses and on patient management. These findings could have important implications for clinical practice. http://www.clinicaltrial.gov. Unique identifier: NCT01070771.

  18. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  19. Direct and nearby lightning strike interaction with test power distribution lines

    Science.gov (United States)

    Schoene, Jens Daniel

    The interaction of direct and nearby rocket-triggered lightning with two unenergized three-phase power distribution lines of about 800 m length was studied at the International Center for Lightning Research and Testing in Florida. A horizontally-configured line was tested in 1999 and 2000, a vertically-configured line in 2001, 2002, and 2003, and a vertically-configured line with overhead ground wire in 2004. All lines were equipped with arresters and, additionally, in 2003, the vertical line had a polemounted transformer. During the 2000, 2001, and 2002 direct strike experiments, arresters frequently failed, but there was no arrester failures either during the 2003 direct strike experiment when the transformer was on the line or during the 2004 direct strike experiment when the lightning current was injected into the overhead ground wire. All line configurations except the one tested in 2004 commonly exhibited flashovers. The division of return stroke currents for the vertically-configured line was initially similar to the division on the horizontally-configured line (that is, the arresters closest to the strike point conducted the bulk of the impulsive current). After some tens of microseconds the currents in all arresters on the vertically-configured line equalized, while the close arrester currents on the horizontally-configured line still conducted significantly more current than the remote arresters. The lightning current division for direct strikes to a phase conductor is successfully modeled with the Electromagnetic Transient Program (EMTP) for the vertically-configured line and, if the residual voltage of the close arresters is reduced by 20%, successfully modeled for the horizontally-configured line. Currents on the vertically-configured line induced by nearby lightning strikes were measured and compared to results calculated using the LIOV-EMTP96 code. It was found that during a lightning strike 11 m from a grounded line pole, a significant fraction of

  20. 14 CFR 29.631 - Bird strike.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Bird strike. 29.631 Section 29.631... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Design and Construction General § 29.631 Bird strike. The... safe landing (for Category B) after impact with a 2.2-lb (1.0 kg) bird when the velocity of the...

  1. Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures.

    Science.gov (United States)

    Kim, Jin Young; Lee, Young Ho; Gong, Hyun Sik; Lee, Sang Lim; Lee, Sang Ki; Baek, Goo Hyun

    2013-09-01

    To evaluate the clinical and radiographic outcomes of tension band wiring of displaced olecranon fractures treated using Kirschner wires with eyelets to assess their clinical performance with respect to complications such as backing out of the K-wires, restriction of forearm rotation, and neurovascular injury. The authors retrospectively reviewed 44 patients treated for an isolated, displaced olecranon fracture and checked range of motion, postoperative pain, complications, and incidence of hardware removal. The mean follow-up period was 41 months (range, 26-73 mo). All fractures united, and anatomical reduction was achieved in all cases at final follow-up. Mean elbow flexion was 135° (range, 115° to 140°), and mean elbow extension was 4° (range, 0° to 15°). No pin migration, restriction of forearm rotation, or neurovascular injury occurred. Hardware removal was performed in 8 cases (18%). Compared to previous results with conventional Kirschner wires, no meaningful improvement in postoperative pain level or in the rate of hardware removal was observed. Tension band wiring using the pin studied produced excellent clinical and radiologic outcomes for the treatment of isolated, displaced Mayo type IIA and some type IIB olecranon fractures. The pin was effective in preventing the backing out of Kirschner wires and avoiding the complications associated with anterior cortical engagement of Kirschner wires, such as neurovascular injury or restriction of forearm rotation. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  2. TEMPERATURE-DEFORMATION CRITERION OF OPTIMIZATION OF FINE DRAWING HIGH CARBON WIRE ROUTE

    Directory of Open Access Journals (Sweden)

    Y. L. Bobarikin

    2012-01-01

    Full Text Available The temperature-deformation criterion of assessment and optimization of routes of the thin high-carbon wire drawing enabling to increase plastic properties of wire at retaining of its durability is offered.

  3. Geological Effects on Lightning Strike Distributions

    KAUST Repository

    Berdahl, J. Scott

    2016-05-16

    Recent advances in lightning detection networks allow for detailed mapping of lightning flash locations. Longstanding rumors of geological influence on cloud-to-ground (CG) lightning distribution and recent commercial claims based on such influence can now be tested empirically. If present, such influence could represent a new, cheap and efficient geophysical tool with applications in mineral, hydrothermal and oil exploration, regional geological mapping, and infrastructure planning. This project applies statistical analysis to lightning data collected by the United States National Lightning Detection Network from 2006 through 2015 in order to assess whether the huge range in electrical conductivities of geological materials plays a role in the spatial distribution of CG lightning. CG flash densities are mapped for twelve areas in the contiguous United States and compared to elevation and geology, as well as to the locations of faults, railroads and tall towers including wind turbines. Overall spatial randomness is assessed, along with spatial correlation of attributes. Negative and positive polarity lightning are considered separately and together. Topography and tower locations show a strong influence on CG distribution patterns. Geology, faults and railroads do not. This suggests that ground conductivity is not an important factor in determining lightning strike location on scales larger than current flash location accuracies, which are generally several hundred meters. Once a lightning channel is established, however, ground properties at the contact point may play a role in determining properties of the subsequent stroke.

  4. Aesthetic nickel titanium wires--how much do they deliver?

    Science.gov (United States)

    Kaphoor, Anil Abdul; Sundareswaran, Shobha

    2012-10-01

    The purpose of this study was to evaluate and compare the force levels of aesthetic Ni-Ti wires to regular Ni-Ti wires of the same dimension and evaluate their mechanical properties. Aesthetic and regular maxillary superelastic Ni-Ti wires (0.016 × 0.022) from four different manufacturers (G&H Wire Company, TP Orthodontics, GAC International, and Ortho Organizers) were selected and grouped I-IV. The loading and unloading values were compared using a three-point bending test. The unloading end values were also recorded to evaluate the recovery of archwires after each deflection. The unloading values were recorded at 0.5, 1.5, and 2.5 mm after loading deflections of 1, 2, and 3 mm, respectively. Cross-sectional scanning electron microscopy was used to assess the coating thickness of aesthetic wires. The results, statistically analysed, showed a significant decrease in force values for the aesthetic wires in groups I, III, and IV (P wires of the same dimension from the same manufacturer. There was no significant difference in force values for group II wires. A statistically significant decrease in force values of epoxy-coated wires was observed in groups I, III, and IV only. This is of obvious clinical significance during wire selection. The group II coated wires, however, exhibited forces comparable to their regular Ni-ti wires with a difference that was statistically insignificant. The end values of aesthetic wires showed almost complete recovery for groups I, II, and III after 2 and 3 mm deflections.

  5. Lightning Strike in Pregnancy With Fetal Injury.

    Science.gov (United States)

    Galster, Kellen; Hodnick, Ryan; Berkeley, Ross P

    2016-06-01

    Injuries from lightning strikes are an infrequent occurrence, and are only rarely noted to involve pregnant victims. Only 13 cases of lightning strike in pregnancy have been previously described in the medical literature, along with 7 additional cases discovered within news media reports. This case report presents a novel case of lightning-associated injury in a patient in the third trimester of pregnancy, resulting in fetal ischemic brain injury and long-term morbidity, and reviews the mechanics of lightning strikes along with common injury patterns of which emergency providers should be aware. Copyright © 2016 Wilderness Medical Society. Published by Elsevier Inc. All rights reserved.

  6. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...... new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as “wired to freedom,” we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear...

  7. Wiring and lighting

    CERN Document Server

    Kitcher, Chris

    2013-01-01

    Wiring and Lighting provides a comprehensive guide to DIY wiring around the home. It sets out the regulations and legal requirements surrounding electrical installation work, giving clear guidelines that will enable the reader to understand what electrical work they are able to carry out, and what the testing and certification requirements are once the work is completed. Topics covered include: Different types of circuits; Types of cables and cable installation under floors and through joists; Isolating, earthing and bonding; Accessory boxes and fixings; Voltage bands; Detailed advice on safe

  8. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  9. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  10. Silicon Nano wires with MoSx and Pt as Electrocatalysts for Hydrogen Evolution Reaction

    International Nuclear Information System (INIS)

    Hsieh, S.H.; Ho, S.T.; Chen, W.J.

    2016-01-01

    A convenient method was used for synthesizing Pt-nanoparticle//silicon nano wires nano composites. Obtained Pt-/silicon nano wires electrocatalysts were characterized by transmission electron microscopy (TEM). The hydrogen evolution reaction efficiency of the Pt-/silicon nano wire nano composite catalysts was assessed by examining polarization and electrolysis measurements under solar light irradiations. The electrochemical characterizations demonstrate that Pt-/silicon nano wire electrodes exhibited an excellent catalytic activity for hydrogen evolution reaction in an acidic electrolyte. The hydrogen production capability of Pt-/silicon nano wires is also comparable to /silicon nano wires and Pt/silicon nano wires. Electrochemical impedance spectroscopy experiments suggest that the enhanced performance of Pt-/silicon nano wires can be attributed to the fast electron transfer between Pt-/silicon nano wire electrodes and electrolyte interfaces.

  11. Ultrasound-guided wire localization of lesions detected on ...

    African Journals Online (AJOL)

    Background: Wire localization for planned surgical treatment in the management of breast cancer is underutilized in our environment. The objective of this study is to assess the role of ultrasound-guided wire localization of breast masses detected on screening mammography and its impact on biopsy and breast ...

  12. Expeditionary Strike Group: Command Structure Design Support

    National Research Council Canada - National Science Library

    Hutchins, Susan G; Kemple, William G; Kleinman, David L; Hocevar, Susan P

    2005-01-01

    An Expeditionary Strike Group (ESG) is a new capability mix that combines the combat power of three surface combatants and one submarine with an Amphibious Readiness Group/ Marine Expeditionary Unit...

  13. The Chicago Teachers Strike and Its Public

    Science.gov (United States)

    Shuffelton, Amy B.

    2014-01-01

    This article considers the 2012 Chicago Teachers Strike in light of John Dewey's "The Public and Its Problems." It engages Dewey's conceptualization of practical reason to challenge the educational reform movement's commitment to technocratic decision-making.

  14. Strikes in the public sector in Denmark

    DEFF Research Database (Denmark)

    Scheuer, Steen; Ibsen, Flemming; Høgedahl, Laust

    2016-01-01

    This article looks at strikes by employees in the public sector, discusses the theoretical background to these conflicts and shows – based on a case study of three strikes in the Danish public sector – how different union strategies lead to very different outcomes in terms of economic gains......, while public sector unions trying to move up the wage hierarchy cannot expect much help from fellow public sector unions, often quite the reverse....

  15. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  16. Wire EDM for Refractory Materials

    Science.gov (United States)

    Zellars, G. R.; Harris, F. E.; Lowell, C. E.; Pollman, W. M.; Rys, V. J.; Wills, R. J.

    1982-01-01

    In an attempt to reduce fabrication time and costs, Wire Electrical Discharge Machine (Wire EDM) method was investigated as tool for fabricating matched blade roots and disk slots. Eight high-strength nickel-base superalloys were used. Computer-controlled Wire EDM technique provided high quality surfaces with excellent dimensional tolerances. Wire EDM method offers potential for substantial reductions in fabrication costs for "hard to machine" alloys and electrically conductive materials in specific high-precision applications.

  17. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  18. Command Wire Sensor Measurements

    Science.gov (United States)

    2012-09-01

    CFAR Constant False Alarm Rate CWIE Command Wire-Improvised Explosive Device EMI Electromagnetic Induction GPR Ground Penetrating Radar...this, some type of constant false alarm rate ( CFAR ) receiver is required. CFAR automatically raises the threshold level to keep clutter echoes and

  19. Transport in quantum wires

    Indian Academy of Sciences (India)

    Transport in quantum wires. SIDDHARTHA LAL, SUMATHI RAO£ and DIPTIMAN SEN. Centre for Theoretical Studies, Indian Institute of Science, Bangalore 560 012, India. £ Harish-chandra Research Institute, Chhatnag Road, Jhusi, Allahabad 211 019, India. Abstract. With a brief introduction to one-dimensional channels ...

  20. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  1. Degradation of orthodontic wires under simulated cariogenic and erosive conditions

    Directory of Open Access Journals (Sweden)

    Laura Cavalcante Lima JABER

    2014-08-01

    Full Text Available This study examined the effect of cariogenic and erosive challenges (CCs and ECs, respectively on the degradation of copper-nickel-titanium (CuNiTi orthodontic wires. Sixty wire segments were divided into four treatment groups and exposed to CCs, ECs, artificial saliva, or dry storage (no-treatment control. CC and EC were simulated using a demineralizing solution (pH 4.3 and a citric acid solution (pH 2.3, respectively. Following treatment, the average surface roughness (Ra of the wires was assessed, and friction between the wires and a passive self-ligating bracket was measured. CuNiTi wires subjected to ECs exhibited significantly higher Ra values than did those that were stored in artificial saliva. In contrast, surface roughness was not affected by CCs. Finally, friction between the treated wires and brackets was not affected by ECs or CCs. Our results indicate that CuNiTi orthodontic wires may suffer degradation within the oral cavity, as ECs increased the surface roughness of these wires. However, rougher surfaces did not increase friction between the wire and the passive self-ligating bracket.

  2. Degradation of orthodontic wires under simulated cariogenic and erosive conditions.

    Science.gov (United States)

    Jaber, Laura Cavalcante Lima; Rodrigues, José Augusto; Amaral, Flávia Lucisano Botelho; França, Fabiana Mantovani Gomes; Basting, Roberta Tarkany; Turssi, Cecilia Pedroso

    2014-01-01

    This study examined the effect of cariogenic and erosive challenges (CCs and ECs, respectively) on the degradation of copper-nickel-titanium (CuNiTi) orthodontic wires. Sixty wire segments were divided into four treatment groups and exposed to CCs, ECs, artificial saliva, or dry storage (no-treatment control). CC and EC were simulated using a demineralizing solution (pH 4.3) and a citric acid solution (pH 2.3), respectively. Following treatment, the average surface roughness (Ra) of the wires was assessed, and friction between the wires and a passive self-ligating bracket was measured. CuNiTi wires subjected to ECs exhibited significantly higher Ra values than did those that were stored in artificial saliva. In contrast, surface roughness was not affected by CCs. Finally, friction between the treated wires and brackets was not affected by ECs or CCs. Our results indicate that CuNiTi orthodontic wires may suffer degradation within the oral cavity, as ECs increased the surface roughness of these wires. However, rougher surfaces did not increase friction between the wire and the passive self-ligating bracket.

  3. Women, transition and strikes in Serbia

    Directory of Open Access Journals (Sweden)

    Novaković Nada G.

    2014-01-01

    Full Text Available The author, in a sociological way, describes and analyzes the concepts of transition, privatization and strikes in Serbia, particularly the place of women in it. It examines the most important economic and social causes and consequences of these phenomena. The main hypothesis is: women's strikes in the Serbian transition are less efficient than strikes and public protests of women in the developed world and the second Yugoslavia. A strike is a class conflict, in which the workers are fighting for their social and economic rights, threatened by the capitalist class. Elites in government and state authorities protect the interests of big capital at the detriment of the interests of the majority of workers. Exploring women's strikes in transition reveals the nature of the social and political system. Their strikes in enterprises, the blocking of public spaces and public protests are systemic, ie. class determined. As the transition was very fast, the resistance of the strikers was inefficient, and the protests of women became an expression of desperation against the loss of jobs and basic resources for lifehood. In short, this research is about the main causes, the organizational forms and the consequences of strikes in which the majority were women. For this purpose, the author chose to describe an array of strikes in the industries and the companies where women are most employed. The choice of strikes in the economic sector is not accidental, but a consequence of the fact that the women there were the most vulnerable. Women in public institutions and companies had much higher financial and social position. They are less likely to strike and publicly protested. After 2000, these strikes were more successful than worker's strikes in textile, food processing, manufacturing and trade. Relationship between the government and the public towards them was tainted by self-interest and selective. The main criterion for the selection of companies and

  4. Active and recent strike-slip tectonics

    Science.gov (United States)

    Nur, Amos; Boccaletti, Mario

    An international workshop cosponsored by the Department of Geology, University of Florence, Italy and the Department of Geophysics, Stanford University, Stanford, Calif., was held in Florence, Italy, April 18-20, 1989,on the topic of active and recent strike-slip tectonics in the continental crust. Workshop participants from Turkey, Ethiopia, Israel, Greece, and various universities in Italy, Spain, West Germany, France, the United Kingdom, Brazil, and the United States reported on a broad range of studies involving strike-slip faulting in continental crustal setting. As it turned out, much of the work reported on involved aspects of strike-slip faulting that are only poorly understood, especially crustal deformation, which is distributed over a multiplicity of faults, or even fault domains.One of the rewarding aspects of this workshop was the diversity of geographic areas and geological settings covered by the reporters. The north and east Anatolian faults, the Dead Sea transform zone, western Turkey, north and central Greece, Malta, Sicily, southern Italy, the bethic Cordillera in southern Spain, Tunisia, Tibet and southwest China, offshore Brazil, Alaska, Nevada, and California. A recurring observation reported for all those areas was mixed mode faulting, i.e., the coterminous or sequential occurrence of strike-slip and normal faulting, or strike-slip and thrust, and in many instances also strikeslip, normal and thrust faulting in a single tectonic setting.

  5. Dental Arch Wire

    Science.gov (United States)

    1979-01-01

    Straightening teeth is an arduous process requiring months, often years, of applying corrective pressure by means of arch wires-better known as brace-which may have to be changed several times in the course of treatment. A new method has been developed by Dr. George Andreasen, orthodontist and dental scientist at the University of Iowa. The key is a new type of arch wire material, called Nitinol, with exceptional elasticity which helps reduce the required number of brace changes. An alloy of nickel and titanium, Nitinol was originally developed for aerospace applications by the Naval Ordnance Laboratory, now the Naval Surface Weapons Laboratory, White Oaks, Maryland. NASA subsequently conducted additional research on the properties of Nitinol and on procedures for processing the metal.

  6. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  7. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  8. Insulator and Clerance Requirements in Overhead Line Transmission Systems without Shield Wires

    DEFF Research Database (Denmark)

    Sørensen, Thomas Kjærsgaard; Holbøll, Joachim

    2008-01-01

    This paper theoretically examines the required insulation lengths and clearances in 400 kV overhead line systems when not making use of ground wires as lightning protection. The influence of lightning strikes to the system is investigated based on dynamic transmission line simulations of a 400 kV...

  9. ELMs, strike point jumps and SOL currents

    International Nuclear Information System (INIS)

    Solano, Emilia R.; Jachmich, S.; Villone, F.; Hawkes, N.; Guenther, K.; Korotkov, A.; Stamp, M.; Andrew, P.; Conboy, J.; Mattews, G.F.; Corre, Y.; Loarte, A.; Pitts, R.A.; Cenedese, A.; Kempenaars, M.; Bolzonella, T.; Rachlew, E.

    2005-01-01

    Plasma equilibria before and after ELMs in JET are investigated. ELMs could be associated with fragile equilibria and separatrix instabilities: previously closed field lines would open up, releasing plasma current and leading to the formation of a new, smaller separatrix. This model could explain experimental observations of sudden jumps and shifts in strike point positions. Novel instability mechanisms are discussed to explain the large transient jumps observed in the strike point position: positive X-point instability, due to positive toroidal current density at the X-point and diamagnetic instability, due to negative inboard toroidal current density. (author)

  10. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  11. Strikes, solidarity and scabs. Union members participation norms and williengness to participate in strikes.

    NARCIS (Netherlands)

    Akkerman, A.; Born, M.; Torenvlied, R.

    2013-01-01

    This article studies how participation norms affect workers' willingness to strike. A factor analysis on the responses of 468 Dutch union members about appropriate behavior during a strike produces two factors. The first factor reflects a "solidarity norm" favoring group solidarity; the second

  12. Control of flow past a circular cylinder via a spanwise surface wire: effect of the wire scale

    Energy Technology Data Exchange (ETDEWEB)

    Ekmekci, Alis [University of Toronto Institute for Aerospace Studies, Toronto, ON (Canada); Rockwell, Donald [Lehigh University, Department of Mechanical Engineering, Bethlehem, PA (United States)

    2011-09-15

    Flow phenomena induced by a single spanwise wire on the surface of a circular cylinder are investigated via a cinema technique of particle image velocimetry (PIV). The primary aim of this investigation is to assess the effect of the wire scale. To this end, consideration is given to wires with different diameters that are 0.5, 1.2, and 2.9% of the cylinder diameter. The Reynolds number has a subcritical value of 10,000. Compared to the thickness of the unperturbed boundary layer developing around the cylinder between 5 and 75 from the forward stagnation point, the former two wires have smaller scales and the latter has a larger scale. Two angular locations of the wire, defined with respect to the forward stagnation point of the cylinder, are found to be critical. When the wire is located at these critical angles, either the most significant extension or the contraction of the time-mean separation bubble occurs in the near wake. These critical angles depend on the wire scale: the smaller the wire, the larger the critical angle. The small-scale and large-scale wires that have diameters of 1.2 and 2.9% of the cylinder diameter induce bistable shear-layer oscillations between different separation modes when placed at their respective critical angles corresponding to maximum extension of the near-wake bubble. These oscillations have irregular time intervals that are much longer than the time scale associated with the classical Karman instability. Moreover, the large-scale wire can either significantly attenuate or intensify the Karman mode of vortex shedding at the critical states; in contrast, the small-scale wires do not notably alter the strength of the Karman instability. (orig.)

  13. HUNGER STRIKES AND FORCE-FEEDING IN PRISONS

    Directory of Open Access Journals (Sweden)

    Radu-Florin GEAMĂNU

    2016-05-01

    Full Text Available This study will try to give an overview and assess the international and European standards regarding the management of hunger strikes. We will analyse the international and European standards regarding the force-feeding a prisoner on a hunger strike. The paper will focus on the study of the ECtHR judgements regarding the force-feeding of hunger strikers. Also, we will address the U.S. case and the force-feeding of prisoners which is considered to be, in certain cases, an act of torture based on the international human rights standards. To close with, the study will attempt to go through the recent developments in the Romanian legislation, analysing the legislation and its conformity with the European principles and recommendations, bearing in mind the prohibition, in absolute terms, of torture or inhuman or degrading treatment or punishment.

  14. Three-dimensional impact kinetics with foot-strike manipulations during running

    Directory of Open Access Journals (Sweden)

    Andrew D. Nordin

    2017-12-01

    Conclusion: Loading rate–time assessment identified contrasting impact characteristics in each direction and the 3D resultant following foot-strike manipulations, with potential implications for lower extremity structures in running.

  15. Personality Characteristics of Pre/Post-Strike Air Traffic Control Applicants

    National Research Council Canada - National Science Library

    Schroeder, David

    1997-01-01

    ...) positions within the Federal Aviation Administration for more than 3 decades. This study was designed to assess the relationship between personality characteristics of a group of post-strike applicants (1984...

  16. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  17. The Front Line: No Strikes, Just Balls.

    Science.gov (United States)

    Unks, Gerald

    1979-01-01

    Recent actions of British teachers suggest an alternative to the teacher strike. Those teachers dramatically demonstrated their grievances by withholding the voluntary extra services they customarily perform. American teachers could accomplish the same end by collectively refusing to perform extraneous administrative services: collecting money,…

  18. When Lightning Strikes a Second Time

    Science.gov (United States)

    Allen, Kent

    2017-01-01

    The chances of lightning striking twice are infinitesimal, at best. What are the odds, in middle age, of being struck with a jarring bolt of figurative lightning, then a few months later being an eyewitness as the same sizzle in the sky jolts a group of students--those decision-makers of tomorrow? The author describes two experiences that proved…

  19. Impact of lightning strikes on hospital functions.

    Science.gov (United States)

    Mortelmans, Luc J M; Van Springel, Gert L J; Van Boxstael, Sam; Herrijgers, Jan; Hoflacks, Stefaan

    2009-01-01

    Two regional hospitals were struck by lightning during a one-month period. The first hospital, which had 236 beds, suffered a direct strike to the building. This resulted in a direct spread of the power peak and temporary failure of the standard power supply. The principle problems, after restoring standard power supply, were with the fire alarm system and peripheral network connections in the digital radiology systems. No direct impact on the hardware could be found. Restarting the servers resolved all problems. The second hospital, which had 436 beds, had a lightning strike on the premises and mainly experienced problems due to induction. All affected installations had a cable connection from outside in one way or another. The power supplies never were endangered. The main problem was the failure of different communication systems (telephone, radio, intercom, fire alarm system). Also, the electronic entrance control went out. During the days after the lightening strike, multiple software problems became apparent, as well as failures of the network connections controlling the technical support systems. There are very few ways to prepare for induction problems. The use of fiber-optic networks can limit damage. To the knowledge of the authors, these are the first cases of lightning striking hospitals in medical literature.

  20. [Management of the hunger strike in prison].

    Science.gov (United States)

    Fayeulle, Stéphanie; Renou, Frédéric; Protais, Emmanuel; Hédouin, Valéry; Wartel, Guillaume; Yvin, Jean-Luc

    2010-10-01

    Entering prison can feed pre-existent behavior of demands or generate them. Several means of expression are then used. Hunger strike is an average privileged act. It belongs to prison culture. Estimate how practitioners working in prison take care of the hunger strikers. The study, realised in 2008, was led with all the Units of Consultations and Ambulatory Care in France. It is a declarative investigation where a medical testimony by unit was asked. From 174 "maisons d'arrêt" and establishments for punishment in France, 95 answers were obtained. This situation was already seen by 98,8% of the doctors. The motives for hunger strike were mainly judicial for "maisons d'arrêt" (70,1%) and prison motives for detention centers (68,7%). Mainly, doctors opted for a neutral attitude (63% of the cases). The hunger strikes were mostly brief (less than a week in 85% of the cases). Only 5,5% of the doctors proposed written information concerning the risks incurred during a fast. A doctor in 4 approximately (23%) was already witness to complications due to fasting. The fact that a patient may refuse care makes the medical approach difficult. Faced with such a situation, 45% of the doctors privileged their duty of care, 28% respected the patient's wishes, and 27% did not pronounce. From a therapeutic point of view, the place of treatment using vitamins was rarely recognized (32,7%). Hunger strike is rarely severe, but it is rather frequent in prison so that every doctor working there will be confronted with it. The refeeding syndrome seems often ignored. The coverage of hunger strike is governed by the law, but ethical questions stay in the appreciation of every doctor. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  1. Factors affecting defensive strike behavior in Brown Treesnakes (Boiga irregularis) provoked by humans

    Science.gov (United States)

    Spencer, McKayka M.; Lardner, Bjorn; Mazurek, M.J.; Reed, Robert N.

    2015-01-01

    Striking is a typical antipredator defense exhibited by many species of snakes. While trapping Brown Treesnakes (Boiga irregularis) on Guam, we observed that snakes most frequently struck at an approaching person at a site where snakes had been trapped, marked, and handled in the past. Using a combination of between-sites and within-site comparisons, we assessed if the propensity to strike was correlated with capture histories (both recent and long-term), snake size, body condition (a proxy to nutritional stress), sex, or tail condition (broken or intact), while controlling for confounding variables. We confirmed that propensity to strike was higher at the site where we had been conducting capture-mark-recapture for several years. However, we were unable to demonstrate a correlation between striking tendencies and individual recent or long-term capture histories. The only morphological covariate that had an effect on strike propensity was sex, with females striking more often than males. After removing the site effect from our model, we found that snakes missing parts of their tails were more likely to strike than snakes with intact tails. We have yet to identify the factor(s) that cause the pronounced difference across sites in snake propensity to strike, and data from additional sites might help elucidate any geographical patterns.

  2. Gait Retraining From Rearfoot Strike to Forefoot Strike does not change Running Economy.

    Science.gov (United States)

    Roper, Jenevieve Lynn; Doerfler, Deborah; Kravitz, Len; Dufek, Janet S; Mermier, Christine

    2017-12-01

    Gait retraining is a method for management of patellofemoral pain, which is a common ailment among recreational runners. The present study investigated the effects of gait retraining from rearfoot strike to forefoot strike on running economy, heart rate, and respiratory exchange ratio immediately post-retraining and one-month post-retraining in recreational runners with patellofemoral pain. Knee pain was also measured. Sixteen participants (n=16) were randomly placed in the control (n=8) or experimental (n=8) group. A 10-minute treadmill RE test was performed by all subjects. The experimental group performed eight gait retraining running sessions where foot strike pattern was switched from rearfoot strike to forefoot strike, while the control group received no intervention. There were no significant differences for running economy (p=0.26), respiratory exchange ratio (p=0.258), or heart rate (p=0.248) between the groups. Knee pain reported on a visual analog scale was also significantly reduced (p<0.05) as a result of retraining. The present study demonstrates that retraining from rearfoot strike to forefoot strike did not affect running economy up to one-month post-retraining while reducing running-related patellofemoral pain. © Georg Thieme Verlag KG Stuttgart · New York.

  3. Wire communication engineering

    International Nuclear Information System (INIS)

    Son, Byeong Tae

    1997-02-01

    This book describes wire telecommunication engineering/ It is divided into eleven chapter, which deal with Introduction with development of telecommunication, voice and sound wave and communication network, Telegraphy with summary of telegraphy, code of telegraphy, communication speed, morse and telex, Telephone on structure, circuit and image telephone, Traffic on telecommunication traffic, transmission of line about theory, cable line and loaded cable, carrier communication with carrier telegraphy and carrier telephone, optical communication with types, structure, specialty, laser and equipment, DATA, Mobile telecommunication on summary, mobile telephone, radio paging and digital mobile telecommunication, ISDN with channel of ISDN, and service of ISDN, and design of telecommunication.

  4. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  5. The Micro Wire Detector

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M. E-mail: maximo.plo@cern.ch; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C

    1999-10-11

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 {mu}m{sup 2} apertures, crossed by 25 {mu}m anode strips to which it is attached by 50 {mu}m kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  6. Epitaxial semiconductor quantum wires.

    Science.gov (United States)

    Wu, J; Chen, Y H; Wang, Z G

    2008-07-01

    The investigation on the direct epitaxial quantum wires (QWR) using MBE or MOCVD has been persuited for more than two decades, more lengthy in history as compared with its quantum dot counterpart. Up to now, QWRs with various structural configurations have been produced with different growth methods. This is a reviewing article consisting mainly of two parts. The first part discusses QWRs of various configurations, together with laser devices based on them, in terms of the two growth mechanisms, self-ordering and self-assembling. The second part gives a brief review of the electrical and optical properties of QWRs.

  7. 46 CFR 111.60-11 - Wire.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be...

  8. Striking dynamics and kinetic properties of boxing and MMA gloves

    Directory of Open Access Journals (Sweden)

    Benjamin Lee

    2014-08-01

    Full Text Available With the growing popularity of Mixed Martial Arts (MMA as a competitive sport, questions regarding the dynamic response and properties of MMA gloves arise. High-energy impacts from punches are very similar to boxing yet MMA competition requires the use of 4 oz fingerless glove, compared to the larger full enclosure boxing glove. This work assessed the kinetic properties and strike dynamics of MMA gloves and compared findings with traditional boxing gloves. Gloves mounted on a molded fist were impacted repetitively on an instrumental anvil designed for impact, over a 5 hour period resulting in 10,000 continuous and consistent strikes. Kinetic data from impacts were sampled at the beginning of the data collection and subsequently every 30 minutes (every 1,000 strikes. MMA gloves produced 4-5 times greater peak force and 5 times faster load rate compared to the boxing glove. However, MMA gloves also showed signs of material fatigue, with peak force increasing by 35% and rate of loading increasing by 60% over the duration of the test. Boxing glove characteristics did deteriorate but to a lesser extent. In summary, the kinetic properties of MMA glove differed substantially from the boxing glove resulting in impacts characterized by higher peak forces and more rapid development of force. Material properties including stiffness and thickness play a role in the kinetic characteristics upon impact, and can be inferred to alter injury mechanisms of blunt force trauma.

  9. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  10. Topological phases and transport properties of screened interacting quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Hengyi, E-mail: hengyi.xu@njnu.edu.cn [School of Physics and Technology, Nanjing Normal University, Nanjing 210023 (China); Xiong, Ye [School of Physics and Technology, Nanjing Normal University, Nanjing 210023 (China); Wang, Jun [Department of Physics, Southeast University, Nanjing 210096 (China)

    2016-10-14

    We study theoretically the effects of long-range and on-site Coulomb interactions on the topological phases and transport properties of spin–orbit-coupled quasi-one-dimensional quantum wires imposed on a s-wave superconductor. The distributions of the electrostatic potential and charge density are calculated self-consistently within the Hartree approximation. Due to the finite width of the wires and charge repulsion, the potential and density distribute inhomogeneously in the transverse direction and tend to accumulate along the lateral edges where the hard-wall confinement is assumed. This result has profound effects on the topological phases and the differential conductance of the interacting quantum wires and their hybrid junctions with superconductors. Coulomb interactions renormalize the gate voltage and alter the topological phases strongly by enhancing the topological regimes and producing jagged boundaries. Moreover, the multicritical points connecting different topological phases are modified remarkably in striking contrast to the predictions of the two-band model. We further suggest the possible non-magnetic topological phase transitions manipulated externally with the aid of long-range interactions. Finally, the transport properties of normal–superconductor junctions are further examined, in particular, the impacts of Coulomb interactions on the zero-bias peaks related to the Majorana fermions and near zero-energy peaks. - Highlights: • A model of the screened Coulomb interactions in Majorana wires is proposed. • The interacting topological phase diagrams in multiband quantum wires are revealed. • The Majorana fermions in interacting multiband quantum wires are investigated.

  11. Improved superconducting magnet wire

    Science.gov (United States)

    Schuller, I.K.; Ketterson, J.B.

    1983-08-16

    This invention is directed to a superconducting tape or wire composed of alternating layers of copper and a niobium-containing superconductor such as niobium of NbTi, Nb/sub 3/Sn or Nb/sub 3/Ge. In general, each layer of the niobium-containing superconductor has a thickness in the range of about 0.05 to 1.5 times its coherence length (which for Nb/sub 3/Si is 41 A) with each copper layer having a thickness in the range of about 170 to 600 A. With the use of very thin layers of the niobium composition having a thickness within the desired range, the critical field (H/sub c/) may be increased by factors of 2 to 4. Also, the thin layers of the superconductor permit the resulting tape or wire to exhibit suitable ductility for winding on a magnet core. These compositions are also characterized by relatively high values of critical temperature and therefore will exhibit a combination of useful properties as superconductors.

  12. The effect of clamping a tensioned wire: implications for the Ilizarov external fixation system.

    Science.gov (United States)

    Watson, M A; Mathias, K J; Maffulli, N; Hukins, D W L

    2003-01-01

    This study demonstrates that clamping a tensioned wire can cause a reduction in wire tension. Tension (about 1275 N) was applied to a wire that was subsequently clamped, using cannulated bolts, to the steel half-ring of an Ilizarov external fixator. The tension in the wire was monitored before, during and after clamping. The apparatus was disassembled and the deformations in the wire caused by the clamps were measured. This experiment was repeated 15 times. When the wire was clamped to the frame, the wire tension was reduced by 22 +/- 7 per cent (mean +/- standard deviation, SD). The drop in wire tension was linearly correlated (r = 0.96; p toothpaste from a tube) and so reduce its tension during fixator assembly. To assess the magnitude of this effect in the clinical situation, the FE model analysis was repeated to replicate clamping a 1.8-mm-diameter wire to a 180-mm-diameter steel Ilizarov ring component. The analysis showed that for these conditions the tension reduced by 8-29 per cent. The results of this study highlight a general engineering problem: how can a tensioned wire be secured to a structure without an appreciable loss of tension? If the performance of the structure depends on the wire tension, this performance will change when the wire is secured.

  13. ["Bell-striking" Saying of Acupuncture Therapy].

    Science.gov (United States)

    Zhao, Jing-Sheng

    2017-04-25

    As an analogy, a prototype of "bell-striking" is proposed in the present paper for exploring the basic properties, major elements, and potential mechanisms of acupuncture stimulation. On the strength of analysis on the physiological basis of acupuncture effect, several fundamental aspects of acupuncture are summarized as a) the body-surface stimulating characters, b) general and local effects, and c) triggering the auto-regulative function of the organism, which mimics the "bell-striking" response. Namely, when stroke, bell will chime, otherwise, chiming will not be heard. During analyzing special contents of acupuncture theory, its formative background should not be separated, and it is improper to take, modern medical theory of the human body as the guiding thinking way for researching the ancient Chinese medical literature.

  14. Central hyperadrenergic state after lightning strike.

    Science.gov (United States)

    Parsaik, Ajay K; Ahlskog, J Eric; Singer, Wolfgang; Gelfman, Russell; Sheldon, Seth H; Seime, Richard J; Craft, Jennifer M; Staab, Jeffrey P; Kantor, Birgit; Low, Phillip A

    2013-08-01

    To describe and review autonomic complications of lightning strike. Case report and laboratory data including autonomic function tests in a subject who was struck by lightning. A 24-year-old man was struck by lightning. Following that, he developed dysautonomia, with persistent inappropriate sinus tachycardia and autonomic storms, as well as posttraumatic stress disorder (PTSD) and functional neurologic problems. The combination of persistent sinus tachycardia and episodic exacerbations associated with hypertension, diaphoresis, and agitation was highly suggestive of a central hyperadrenergic state with superimposed autonomic storms. Whether the additional PTSD and functional neurologic deficits were due to a direct effect of the lightning strike on the central nervous system or a secondary response is open to speculation.

  15. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].

    Science.gov (United States)

    Zhang, J; Jiang, X Y; Huang, X W

    2016-06-18

    To investigate the clinical efficacy and outcomes of two separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella. From January 2013 to January 2015, 15 consecutive patients (mean age 54.5 years) with inferior pole fractures of the patella were retrospectively included in this study. All the patients underwent open reduction and internal fixation by separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire through longitudinal incision, 4.5 d (range: 3.1-5.9 d) after initial injury. A safety check for early knee range of motion was performed before wound closure. The complications including infection, nonunion, loss of fixation and any wire breakage or irritation from implant were recorded. Anteroposterior and lateral views of the knee joint obtained during the follow-up were used to assess bony union based on the time when the fracture line disappeared. At the time of the final outpatient follow up, functional evaluation of the knee joint was conducted by Bostman system. The follow-up time was 13.1 months (range: 12-19 months) after surgery on average, immediate motion without immobilization in all the cases was allowed and there was no case of reduction loss of the fracture and wire breakage. There was no case of irritation from the implant. At the final follow-up, the average range of motion (ROM) arc was 126.7° (range: 115°-140°), the average ROM lag versus contralateral healthy leg was 10.3° (range: 0°-35°). The mean Bostman score at the last follow-up was 28.9 (range: 27-30), and graded excellent in most cases. Two separate vertical wiring is an easy and effective method to reduce the displaced inferior pole fracture of patella. Augmentation of separate vertical wiring with tension band and Kirschner-wire plus cerclage wire in these patients provides enough strength to protected the early exercise of the knee joint and

  16. Wire and Packing Tape Sandwiches

    Science.gov (United States)

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  17. Stress distribution of metatarsals during forefoot strike versus rearfoot strike: A finite element study.

    Science.gov (United States)

    Li, Shudong; Zhang, Yan; Gu, Yaodong; Ren, James

    2017-12-01

    Due to the limitations of experimental approaches, comparison of the internal deformation and stresses of the human man foot between forefoot and rearfoot landing is not fully established. The objective of this work is to develop an effective FE modelling approach to comparatively study the stresses and energy in the foot during forefoot strike (FS) and rearfoot strike (RS). The stress level and rate of stress increase in the Metatarsals are established and the injury risk between these two landing styles is evaluated and discussed. A detailed subject specific FE foot model is developed and validated. A hexahedral dominated meshing scheme was applied on the surface of the foot bones and skin. An explicit solver (Abaqus/Explicit) was used to stimulate the transient landing process. The deformation and internal energy of the foot and stresses in the metatarsals are comparatively investigated. The results for forefoot strike tests showed an overall higher average stress level in the metatarsals during the entire landing cycle than that for rearfoot strike. The increase rate of the metatarsal stress from the 0.5 body weight (BW) to 2 BW load point is 30.76% for forefoot strike and 21.39% for rearfoot strike. The maximum rate of stress increase among the five metatarsals is observed on the 1st metatarsal in both landing modes. The results indicate that high stress level during forefoot landing phase may increase potential of metatarsal injuries. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Communication and wiring in the cortical connectome.

    Science.gov (United States)

    Budd, Julian M L; Kisvárday, Zoltán F

    2012-01-01

    In cerebral cortex, the huge mass of axonal wiring that carries information between near and distant neurons is thought to provide the neural substrate for cognitive and perceptual function. The goal of mapping the connectivity of cortical axons at different spatial scales, the cortical connectome, is to trace the paths of information flow in cerebral cortex. To appreciate the relationship between the connectome and cortical function, we need to discover the nature and purpose of the wiring principles underlying cortical connectivity. A popular explanation has been that axonal length is strictly minimized both within and between cortical regions. In contrast, we have hypothesized the existence of a multi-scale principle of cortical wiring where to optimize communication there is a trade-off between spatial (construction) and temporal (routing) costs. Here, using recent evidence concerning cortical spatial networks we critically evaluate this hypothesis at neuron, local circuit, and pathway scales. We report three main conclusions. First, the axonal and dendritic arbor morphology of single neocortical neurons may be governed by a similar wiring principle, one that balances the conservation of cellular material and conduction delay. Second, the same principle may be observed for fiber tracts connecting cortical regions. Third, the absence of sufficient local circuit data currently prohibits any meaningful assessment of the hypothesis at this scale of cortical organization. To avoid neglecting neuron and microcircuit levels of cortical organization, the connectome framework should incorporate more morphological description. In addition, structural analyses of temporal cost for cortical circuits should take account of both axonal conduction and neuronal integration delays, which appear mostly of the same order of magnitude. We conclude the hypothesized trade-off between spatial and temporal costs may potentially offer a powerful explanation for cortical wiring patterns.

  19. Wire metamaterials: physics and applications.

    Science.gov (United States)

    Simovski, Constantin R; Belov, Pavel A; Atrashchenko, Alexander V; Kivshar, Yuri S

    2012-08-16

    The physics and applications of a broad class of artificial electromagnetic materials composed of lattices of aligned metal rods embedded in a dielectric matrix are reviewed. Such structures are here termed wire metamaterials. They appear in various settings and can operate from microwaves to THz and optical frequencies. An important group of these metamaterials is a wire medium possessing extreme optical anisotropy. The study of wire metamaterials has a long history, however, most of their important and useful properties have been revealed and understood only recently, especially in the THz and optical frequency ranges where the wire media correspond to the lattices of microwires and nanowires, respectively. Another group of wire metamaterials are arrays and lattices of nanorods of noble metals whose unusual properties are driven by plasmonic resonances. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Hot wire TIG temper bead welding for nuclear repairs

    International Nuclear Information System (INIS)

    Lambert, J.A.; Gilston, P.F.

    1989-08-01

    A preliminary assessment has been carried out to determine the suitability of the hot wire tungsten inert gas (TIG) welding process for the repair of thick section, ferritic steel nuclear pressure vessels. The objective has been to identify a hot wire TIG temper bead procedure, suitable for repairs without post weld heat treatment. This procedure involves depositing two weld layers with carefully selected welding parameters such that overlapping thermal cycles produce a refined and tempered heat affected zone, HAZ, microstructure. (author)

  1. Thermal performance in circular tube fitted with coiled square wires

    International Nuclear Information System (INIS)

    Promvonge, Pongjet

    2008-01-01

    The effects of wires with square cross section forming a coil used as a turbulator on the heat transfer and turbulent flow friction characteristics in a uniform heat flux, circular tube are experimentally investigated in the present work. The experiments are performed for flows with Reynolds numbers ranging from 5000 to 25,000. Two different spring coiled wire pitches are introduced. The results are also compared with those obtained from using a typical coiled circular wire, apart from the smooth tube. The experimental results reveal that the use of coiled square wire turbulators leads to a considerable increase in heat transfer and friction loss over those of a smooth wall tube. The Nusselt number increases with the rise of Reynolds number and the reduction of pitch for both circular and square wire coils. The coiled square wire provides higher heat transfer than the circular one under the same conditions. Also, performance evaluation criteria to assess the real benefits in using both coil wires of the enhanced tube are determined

  2. Strain sensing systems tailored for tensile measurement of fragile wires

    Science.gov (United States)

    Nyilas, Arman

    2005-12-01

    Fundamental stress versus strain measurements were completed on superconducting Nb3Sn wires within the framework of IEC/TC90 and VAMAS/TWA16. A key task was the assessment of sensing systems regarding resolution, accuracy, and precision when measuring Young's modulus. Prior to actual Nb3Sn wire measurements metallic wires, consisting of copper and stainless steel having diameters similar to the Nb3Sn wire, were extensively investigated with respect to their elastic line properties using different types of extensometers. After these calibration tests Nb3Sn wire measurements of different companies resulted in several important facts with respect to total size and weight of the used extensometers. The size could be correlated to the initial stage of stress versus strain behaviour. In fact, the effect of wire curls resulting from the production line had a profound effect on Young's modulus measurements. Within this context, the possibility of determining Young's modulus from unloading compliance lines in the plastic regime of the stress-strain curve was considered. The data obtained using this test methodology were discussed under consideration of the composite nature of Nb3Sn wire. In addition, a non-contacting sensing system based on a double-beam laser extensometer was used to investigate the potential of this new sensing system.

  3. Strain sensing systems tailored for tensile measurement of fragile wires

    International Nuclear Information System (INIS)

    Nyilas, Arman

    2005-01-01

    Fundamental stress versus strain measurements were completed on superconducting Nb 3 Sn wires within the framework of IEC/TC90 and VAMAS/TWA16. A key task was the assessment of sensing systems regarding resolution, accuracy, and precision when measuring Young's modulus. Prior to actual Nb 3 Sn wire measurements metallic wires, consisting of copper and stainless steel having diameters similar to the Nb 3 Sn wire, were extensively investigated with respect to their elastic line properties using different types of extensometers. After these calibration tests Nb 3 Sn wire measurements of different companies resulted in several important facts with respect to total size and weight of the used extensometers. The size could be correlated to the initial stage of stress versus strain behaviour. In fact, the effect of wire curls resulting from the production line had a profound effect on Young's modulus measurements. Within this context, the possibility of determining Young's modulus from unloading compliance lines in the plastic regime of the stress-strain curve was considered. The data obtained using this test methodology were discussed under consideration of the composite nature of Nb 3 Sn wire. In addition, a non-contacting sensing system based on a double-beam laser extensometer was used to investigate the potential of this new sensing system

  4. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    , therefore, we’ve drawn conclusions and recommendations for future editions of the event, also generalizable to other experiences of gamification especially in events. This report details the methodology and working elements from the design phase, human resources and organization of production......This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and have...... proposed new ones (viralization of the event on social networks and improvement of the integration of international attendees). On the other hand we defined a set of research objectives related to the study of gamification in an eminently social place like an event. Most of the goals have been met and...

  5. Cyber Capabilities for Global Strike in 2035

    Science.gov (United States)

    2012-02-15

    Wallace, Benjamin. “The Rise and Fall of Bitcoin .” Wired, December 2011. Walter, Chip. “Kryder’s Law.” Scientific American, 25 July 2005, available...2011, when a hacker broke into the “ bitcoin ” virtual currency exchange based in Tokyo and spoofed the system by simulating a massive sell-off...driving the exchange rate toward zero, and allowing him to acquire 2,000 bitcoins (worth over $40,000 at the time) for virtually nothing. See: Benjamin

  6. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  7. Acute transient hemiparesis induced by lightning strike.

    Science.gov (United States)

    Rahmani, Seyed Hesam; Faridaalaee, Gholamreza; Jahangard, Samira

    2015-07-01

    According to data from the National Oceanic and Atmospheric Administration,in the years from 1959 to 1994, lightning was responsible for more than 3000 deaths and nearly 10,000 casualties. The most important characteristic features of lightning injuries are multisystem involvement and widely variable severity. Lightning strikes are primarily a neurologic injury that affects all 3 components of the nervous system: central, autonomic,and peripheral. Neurologic complications of lightning strikes vary from transient benign symptoms to permanent disability. Many patients experience a temporary paralysis called keraunoparalysis. Here we reported a 22-year-old mountaineer man with complaining of left sided hemiparesis after being hit by a lightning strike in the mountain 3 hours ago. There was no loss of consciousness at hitting time. On arrival the patient was alert, awake and hemodynamically stable. In neurologic examination cranial nerves were intact, left sided upper and lower extremity muscle force was I/V with a combination of complete sensory loss, and right-sided muscle force and sensory examination were normal. There is not any evidence of significant vascular impairment in the affected extremities. Brain MRI and CT scan and cervical MRI were normal. During 2 days of admission, with intravenous hydration, heparin 5000 unit SC q12hr and physical therapy of the affected limbs, motor and sensory function improved and was normal except mild paresthesia. He was discharged 1 day later for outpatient follow up while vitamin B1 100mg orally was prescribed.Paresthesia improved after 3 days without further sequels.

  8. Lightning strike-induced brachial plexopathy

    Directory of Open Access Journals (Sweden)

    Amita N Bhargava

    2014-01-01

    Full Text Available We describe a patient who presented with a history of lightning strike injury. Following the injury, he sustained acute right upper limb weakness with pain. Clinically, the lesion was located to the upper and middle trunk of the right brachial plexus, and the same confirmed with electrophysiological studies. Nerve damage due to lightning injuries is considered very rare, and a plexus damage has been described infrequently, if ever. Thus, the proposed hypothesis that lightning rarely causes neuropathy, as against high-voltage electric current, due to its shorter duration of exposure not causing severe burns which lead to nerve damage, needs to be reconsidered.

  9. COMPARATIVE STUDY BETWEEN TENSION BAND WIRING OF PATELLAR FRACTURES WITH KIRSCHNER WIRES AND CANNULATED SCREWS IN TERMS OF FUNCTIONAL OUTCOME AND COMPLICATIONS

    Directory of Open Access Journals (Sweden)

    Kumaran Chettiar

    2016-11-01

    Full Text Available BACKGROUND Various treatment modalities are described for the treatment of displaced transverse fractures of patella. As patella is very important biomechanically, open reduction and internal fixation with maximal preservation of patella is the standard treatment. Most commonly used method is modified tension band wiring with Kirschner wires. In a modification, cannulated screws are used instead of K wires and wire is passed through the cannulation of the screw and anterior surface of the patella. The aim of our study was to compare the complications and functional outcomes after surgical treatment of patellar fractures using modified tension band wiring with Kirschner wires and with cannulated screws. MATERIALS AND METHODS This study was conducted in Department of Orthopaedics, Government Medical College, Kozhikode, during the period 2014- 2015. Total sample size was 36. They were randomised into two groups. Among them, 17 had undergone tension band wiring with cannulated screws and 19 with Kirschner wires. They were evaluated in postoperative period at 1 month, 3 months and 6 months by looking for complications like postoperative infection, postoperative loss of reduction, skin irritation by prominent hardware. Functional outcome was assessed by knee pain score and Good Fellows grading of range of motion. RESULTS According to this study while comparing these two surgical techniques, there are no statistically significant differences in terms of complications and functional outcome. We observed that cannulated screw with tension band wiring has better patient tolerance, less complications like skin irritation by prominent hardware, loss of fixation and knee pain. We found that tension band wiring through cannulated screws is technically more difficult than using Kirschner wires. CONCLUSION Although, the statistical analysis showed no significant differences regarding the union and final outcome, cannulated screw with tension band wiring has

  10. Analysis of Simulated Aircraft Lightning Strikes and Their Electromagnetic Effects

    National Research Council Canada - National Science Library

    Gruden, James

    2001-01-01

    To survive the intense electromagnetic fields associated with a lightning strike, proper design of aircraft electrical control systems requires knowledge of the transient current pulse associated with a lightning strike...

  11. Strike-slip tectonics during rift linkage

    Science.gov (United States)

    Pagli, C.; Yun, S. H.; Ebinger, C.; Keir, D.; Wang, H.

    2017-12-01

    The kinematics of triple junction linkage and the initiation of transforms in magmatic rifts remain debated. Strain patterns from the Afar triple junction provide tests of current models of how rifts grow to link in area of incipient oceanic spreading. Here we present a combined analysis of seismicity, InSAR and GPS derived strain rate maps to reveal that the plate boundary deformation in Afar is accommodated primarily by extensional tectonics in the Red Sea and Gulf of Aden rifts, and does not require large rotations about vertical axes (bookshelf faulting). Additionally, models of stress changes and seismicity induced by recent dykes in one sector of the Afar triple junction provide poor fit to the observed strike-slip earthquakes. Instead we explain these patterns as rift-perpendicular shearing at the tips of spreading rifts where extensional strains terminate against less stretched lithosphere. Our results demonstrate that rift-perpendicular strike-slip faulting between rift segments achieves plate boundary linkage during incipient seafloor spreading.

  12. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems. Electrical wiring shall be installed and maintained to conform to SAE J1292—Automobile, Truck, Truck-Tractor...

  13. Modeling birds on wires.

    Science.gov (United States)

    Aydoğdu, A; Frasca, P; D'Apice, C; Manzo, R; Thornton, J M; Gachomo, B; Wilson, T; Cheung, B; Tariq, U; Saidel, W; Piccoli, B

    2017-02-21

    In this paper we introduce a mathematical model to study the group dynamics of birds resting on wires. The model is agent-based and postulates attraction-repulsion forces between the interacting birds: the interactions are "topological", in the sense that they involve a given number of neighbors irrespective of their distance. The model is first mathematically analyzed and then simulated to study its main properties: we observe that the model predicts birds to be more widely spaced near the borders of each group. We compare the results from the model with experimental data, derived from the analysis of pictures of pigeons and starlings taken in New Jersey: two different image elaboration protocols allow us to establish a good agreement with the model and to quantify its main parameters. We also discuss the potential handedness of the birds, by analyzing the group organization features and the group dynamics at the arrival of new birds. Finally, we propose a more refined mathematical model that describes landing and departing birds by suitable stochastic processes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Bird strike incidence at Addis Ababa Bole International Airport ...

    African Journals Online (AJOL)

    The time and rate of bird strike incidences, species composition and number of birds involved in strikes, and the behaviour of birds were recorded at Bole International Airport from December 1994 to December 1995. The gut contents of the birds struck by aircraft were analyzed. A total of 33 bird strikes were recorded during ...

  15. Evaluating the Effects of a Bird Strike Advisory System

    NARCIS (Netherlands)

    Metz, I.C.; Mühlhausen, T; Ellerbroek, J.; Hoekstra, J.M.

    2016-01-01

    Bird strikes have operational impacts and cause economic loss to the aviation industry. In the worst case, the damages resulting from bird strikes lead to crashes. The highest risk for bird strikes lies in the area below 3000 ft and thus mainly in airport environments. Despite intense efforts from

  16. effects of strike cost on economic development in nigeria

    African Journals Online (AJOL)

    USER

    productivity as in most cases strike cost (wages and salaries as well as other unavoidable payments) are paid during the .... Many times the Nigeria Labour Congress (NLC) and students have had to strike against ... the direct compensation package and other conditions of service. This is the most popular cause of strike in ...

  17. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  18. Composite conductor containing superconductive wires

    Energy Technology Data Exchange (ETDEWEB)

    Larson, W.L.; Wong, J.

    1974-03-26

    A superconductor cable substitute made by coworking multiple rods of superconductive niobium--titanium or niobium--zirconium alloy with a common copper matrix to extend the copper and rods to form a final elongated product which has superconductive wires distributed in a reduced cross-section copper conductor with a complete metallurgical bond between the normal-conductive copper and the superconductor wires contained therein is described. The superconductor cable can be in the form of a tube.

  19. 30 CFR 75.701-4 - Grounding wires; capacity of wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...

  20. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  1. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  2. Forward to the Past: Strikes and Striking as Dialogue by other ...

    African Journals Online (AJOL)

    In Nigeria, from the colonial period to the present, the employment of strikes and protests by nationalists, Nigerian workers and civil society groups has been established as one of the potent means of conveying viewpoints, positions as well as the demand for equality, fairness, social justice and reforms. It has been used as ...

  3. Report on UQ Assessmentsto support SESAME wire-wrappedbundle experiment

    Energy Technology Data Exchange (ETDEWEB)

    Popov, Emilian L. [ORNL; Pointer, William David [ORNL

    2017-10-01

    This work assesses the influence of assumptions made when generating a mesh of a wire-wrappedgeometry. The contact region between a wire and its adjacent pin is commonly modeled by eitherembedding the wire to the adjacent pin or trimming the wire so that a gap separates the wire from itsadjacent pin. These models are referred to as close-gap and open-gap approaches herein and are applied totwo geometries. The first geometry consists of a single pin wire-wrapped subchannel. A polyhedral meshand a hexahedral mesh are generated. The second and third geometry are a 7-pin and a 19-pinwire-wrapped bundles meshed with polyhedral elements only. Pressure drops are obtained with theSTAR-CCM+computational fluid dynamic package. Sensitivity analyses of the mesh density, the meshtype, and the turbulent models are performed. Numerical results show that the best match to theexperimental data and to the Cheng-Todreas correlation is obtained with the combination of a hexahedralmesh, the shear stress transport (SST) turbulent model, and the open-gap approach. In the case of the 7-pingeometry, the best results are obtained with the open-gap approach and the SST turbulent model. The19-pin geometry yields contradictory results to the 7-pin geometry results, and thus will require furtherinvestigations.

  4. Strike Point Control for the National Spherical Torus Experiment (NSTX)

    International Nuclear Information System (INIS)

    Kolemen, E.; Gates, D.A.; Rowley, C.W.; Kasdin, N.J.; Kallman, J.; Gerhardt, S.; Soukhanovskii, V.; Mueller, D.

    2010-01-01

    This paper presents the first control algorithm for the inner and outer strike point position for a Spherical Torus (ST) fusion experiment and the performance analysis of the controller. A liquid lithium divertor (LLD) will be installed on NSTX which is believed to provide better pumping than lithium coatings on carbon PFCs. The shape of the plasma dictates the pumping rate of the lithium by channeling the plasma to LLD, where strike point location is the most important shape parameter. Simulations show that the density reduction depends on the proximity of strike point to LLD. Experiments were performed to study the dynamics of the strike point, design a new controller to change the location of the strike point to desired location and stabilize it. The most effective PF coils in changing inner and outer strike points were identified using equilibrium code. The PF coil inputs were changed in a step fashion between various set points and the step response of the strike point position was obtained. From the analysis of the step responses, PID controllers for the strike points were obtained and the controller was tuned experimentally for better performance. The strike controller was extended to include the outer-strike point on the inner plate to accommodate the desired low outer-strike points for the experiment with the aim of achieving 'snowflake' divertor configuration in NSTX.

  5. Developments in the Generation and Interpretation of Wire Codes (invited paper)

    International Nuclear Information System (INIS)

    Ebi, K.L.

    1999-01-01

    Three new developments in the generation and interpretation of wire codes are discussed. First, a method was developed to computer generate wire codes using data gathered from a utility database of the local distribution system and from tax assessor records. This method was used to wire code more than 250,000 residences in the greater Denver metropolitan area. There was an approximate 75% agreement with field wire coding. Other research in Denver suggests that wire codes predict some characteristics of a residence and its neighbourhood, including age, assessed value, street layout and traffic density. A third new development is the case-specular method to study the association between wire codes and childhood cancers. Recent results from applying the method to the Savitz et al and London et al studies suggest that the associations between childhood cancer and VHCC residences were strongest for residences with a backyard rather than street service drop, and for VHCC residences with LCC speculars. (author)

  6. Comparison of Superelasticity of Nickel Titanium Orthodontic Arch wires using Mechanical Tensile Testing and Correlating with Electrical Resistivity.

    Science.gov (United States)

    Sivaraj, Aravind

    2013-06-01

    Application of light and continuous forces for optimum physiological response and least damage to the tooth supporting structures should be the primary aim of the orthodontist. Nickel titanium alloys with the properties of excellent spring back, super elasticity and wide range of action is one of the natural choices for the clinicians to achieve this goal. In recent periods, various wire manufacturers have come with a variety of wires exhibiting different properties. It is the duty of the clinician to select appropriate wires during various stages of treatment for excellent results. For achieving this evaluation of the properties of these wires is essential. This study is focussed on evaluating the super elastic property of eight groups of austenite active nickel titanium wires. Eight groups of archwires bought from eight different manufacturers were studied. These wires were tested through mechanical tensile testing and electrical resistivity methods. Unloading curves were carefully assessed for superelastic behaviour on deactivation. Rankings of the wires tested were based primarily upon the unloading curve's slope Conclusion: Ortho organisers wires ranked first and superior, followed by American Orthodontics and Ormco A wires. Morelli and GAClowland NiTi wires were ranked last. It can be concluded that the performance of these wires based on rankings should be further evaluated by clinical studies. How to cite this article: Sivaraj A. Comparison of Superelasticity of Nickel Titanium Orthodontic Arch wires using Mechanical Tensile Testing and Correlating with Electrical Resistivity. J Int Oral Health 2013; 5(3):1-12.

  7. Collective bargaining and strikes among physicians.

    Science.gov (United States)

    Keith, S N

    1984-11-01

    UNLIKE EMPLOYEES IN OTHER SECTORS OF THE ECONOMY, HEALTH CARE WORKERS ARE DIRECTED TOWARD ONE ULTIMATE GOAL: making people well and keeping them healthy. The development of collective bargaining and union activities during this century has had a great impact on all industries in the United States and the western world. However, only in recent years have workers in the health care sector been affected by the organized labor movement. The history of collective bargaining and strikes among physicians, the key decision-makers in the health care sector, is even more recent. Because of their central position, physicians' collective activity has had and will continue to have tremendous implications for the viability of the present health care system and the quality of patient care. Even though most physicians continue to function as individual, entrepreneurial service providers and "professionals," physicians as a group are more frequently being seen as members of a utility like industry. Their importance to individuals and society as a whole, it can be argued, is second to none; if physicians refuse to work there can be no worse set of outcomes. To estimate the potential future impact of growing collective action on the part of physicians, this article explores the general historical developments.

  8. Wire Rupture Optimization in Wire Electrical Discharge Machining using Taguchi Approach

    Directory of Open Access Journals (Sweden)

    Maher Ibrahem

    2017-01-01

    Full Text Available Wire electrical discharge machining (WEDM is one of the most important nontraditional machining process that is well-known for cutting difficult to machine materials. The wire electrode along with machining parameters control the WEDM process. This research work focuses on optimizing WEDM parameters using Taguchi technique to minimize wire rupture. Experiments have been done using the L18 orthogonal array. Each experiment is repeated three times to ensure accurate readings of the wire rupture. The statistical methods of signal to noise ratio (S/N ratio is applied to study effects of peak current, pulse width, charging time, wire speed, and wire tension on wire rupture. As a results, the peak current, pulse width, and wire tension have the most significant effect on wire rupture followed by charging time and wire speed. The developed analysis can be used in the metal cutting field to identify the optimum machining parameters for less wire rupture.

  9. Enhancing wire-composite bond strength of bonded retainers with wire surface treatment.

    Science.gov (United States)

    Oesterle, L J; Shellhart, W C; Henderson, S

    2001-06-01

    Bonded orthodontic retainers with wires embedded in composite resin are commonly used for orthodontic retention. The purpose of this study was to test, in vitro, various wire surface treatments to determine the optimal method of enhancing the wire-composite bond strength. Coaxial wires and stainless steel wires with different surface treatments were bonded to bovine enamel and then pulled along their long axes with an Instron universal testing machine. Wire surface treatments included placing a right-angle bend in the wire, microetching the wire, and treating the wire with adhesion promoters; combinations of treatments were also examined. The results demonstrated a 24-fold increase in the wire-composite bond strength of wire that was microetched (sandblasted), compared with that of untreated straight wire. The difference between the amount of force required to break the bond produced by microetching alone (246.1 +/- 46.0 MPa) and that required for the bonds produced by the retentive bend (87.8 +/- 16.3 MPa), the adhesion promoters (silane, 11.0 +/- 3.1 MPa; Metal Primer, 28.5 +/- 15.8 MPa), or for any combination of surface treatments, was statistically significant. Microetching a stainless steel wire produced a higher wire-composite bond strength than that obtained from a coaxial wire (113.5 +/- 27.5 MPa). The results of this study indicate that microetching or sandblasting a stainless steel wire significantly increases the strength of the wire-composite bond.

  10. The influence of drawing speed on structure changes in high carbon steel wires

    Directory of Open Access Journals (Sweden)

    M. Suliga

    2015-01-01

    Full Text Available In the paper the influence of the drawing speed on structure changes has been assessed. The Scanning Electron Microscope investigation confirmed that for wires drawn with high total draft, exceeding 80 %, makes it impossible to clearly assess the impact of drawing technology on structural changes in the drawn wires. Thus, to assess the structural changes necessary to apply quantitative methods. On the basis of examination of the wire structure by measuring of electrical resistance, the structure changes in drawn wires has been determined. It has been shown that the increase of drawing speed, especially above 15 m/s, causes an increase in structure defect, with a decline in platelet orientation of cementite in drawn wires.

  11. Children on hunger strike: child abuse or legitimate protest?

    Science.gov (United States)

    Mok, A.; Nelson, E. A.; Murphy, J.; Hampson, A.; Hendriks, J. H.

    1996-01-01

    The issue of children on hunger strike (voluntary total fasting) has not been reported before. The World Medical Association Declaration of Tokyo 1975 and the Declaration of Malta 1991 (revised 1992) provide clinicians with guidelines for the management of adult patients on hunger strike but do not mention children. We report the management of 14 Vietnamese children, aged 1 to 12 years, who took part in a hunger strike at a refugee detention centre in Hong Kong. PMID:8597690

  12. Children on hunger strike: child abuse or legitimate protest?

    OpenAIRE

    Mok, A.; Nelson, E. A.; Murphy, J.; Hampson, A.; Hendriks, J. H.

    1996-01-01

    The issue of children on hunger strike (voluntary total fasting) has not been reported before. The World Medical Association Declaration of Tokyo 1975 and the Declaration of Malta 1991 (revised 1992) provide clinicians with guidelines for the management of adult patients on hunger strike but do not mention children. We report the management of 14 Vietnamese children, aged 1 to 12 years, who took part in a hunger strike at a refugee detention centre in Hong Kong.

  13. The effect of hand dominance on martial arts strikes.

    Science.gov (United States)

    Neto, Osmar Pinto; Silva, Jansen Henrique; Marzullo, Ana Carolina de Miranda; Bolander, Richard P; Bir, Cynthia A

    2012-08-01

    The main goal of this study was to compare dominant and non-dominant martial arts palm strikes under different circumstances that usually happen during martial arts and combative sports applications. Seven highly experienced (10±5 years) right hand dominant Kung Fu practitioners performed strikes with both hands, stances with left or right lead legs, and with the possibility or not of stepping towards the target (moving stance). Peak force was greater for the dominant hand strikes (1593.76±703.45 N vs. 1042.28±374.16 N; p<.001), whereas no difference was found in accuracy between the hands (p=.141). Additionally, peak force was greater for the strikes with moving stance (1448.75±686.01 N vs. 1201.80±547.98 N; p=.002) and left lead leg stance (1378.06±705.48 N vs. 1269.96±547.08 N). Furthermore, the difference in peak force between strikes with moving and stationary stances was statistically significant only for the strikes performed with a left lead leg stance (p=.007). Hand speed was higher for the dominant hand strikes (5.82±1.08 m/s vs. 5.24±0.78 m/s; p=.001) and for the strikes with moving stance (5.79±1.01 m/s vs. 5.29±0.90 m/s; p<.001). The difference in hand speed between right and left hand strikes was only significant for strikes with moving stance. In summary, our results suggest that the stronger palm strike for a right-handed practitioner is a right hand strike on a left lead leg stance moving towards the target. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Concussion in professional football: biomechanics of the striking player--part 8.

    Science.gov (United States)

    Viano, David C; Pellman, Elliot J

    2005-02-01

    Concussive impacts in professional football were simulated in laboratory tests to determine the collision mechanics resulting in injury to the struck player and the biomechanics of the striking players, who were not concussed or neck-injured in the tackle. Twenty-seven helmet-to-helmet collisions were reconstructed in laboratory tests using Hybrid III dummies. The head impact velocity, direction, and kinematics matched game video. Translational and rotational head accelerations and six-axis upper neck loads and moments were used to evaluate how the striking player delivered the concussive blow. The neck injury criterion, Nij, was calculated to assess neck injury risks in the striking player. The time-averaged impact force reached 6372 +/- 2486 N at 7.2 milliseconds because of 46.8 +/- 21.7 g head acceleration and 3624 +/- 1729 N neck compression force in the striking player. Fifty-seven percent of the load was contributed by neck compression. The striking players had their heads down and lined up the impact axis through their necks and torsos. This allowed momentum transfer with minimal neck bending and increased the effective mass of the striking player to 1.67 times that of the struck player at peak load. The impact caused 94.3 +/- 27.5 g head acceleration in the concussed players and 67.9 +/- 14.5 g without concussion (t = 2.06, df = 25, P = 0.025). The striking player's Nij was greater than tolerance in 9 of 27 cases by exceeding the 4000 N neck compression limit. For these cases, the average neck compression force was 6631 +/- 977 N (range, 5210-8194 N). Nij was 1.25 +/- 0.16 for eight cases above the tolerance Nij = 1.0. In the NFL, striking players line up their heads, necks, and torsos to deliver maximum force to the other player in helmet-to-helmet impacts. The concussive force is from acceleration of the striking player's head and torso load through the neck. Even though neck responses exceeded tolerances, no striking player experienced neck injury or

  15. Debunking the viper's strike: harmless snakes kill a common assumption.

    Science.gov (United States)

    Penning, David A; Sawvel, Baxter; Moon, Brad R

    2016-03-01

    To survive, organisms must avoid predation and acquire nutrients and energy. Sensory systems must correctly differentiate between potential predators and prey, and elicit behaviours that adjust distances accordingly. For snakes, strikes can serve both purposes. Vipers are thought to have the fastest strikes among snakes. However, strike performance has been measured in very few species, especially non-vipers. We measured defensive strike performance in harmless Texas ratsnakes and two species of vipers, western cottonmouths and western diamond-backed rattlesnakes, using high-speed video recordings. We show that ratsnake strike performance matches or exceeds that of vipers. In contrast with the literature over the past century, vipers do not represent the pinnacle of strike performance in snakes. Both harmless and venomous snakes can strike with very high accelerations that have two key consequences: the accelerations exceed values that can cause loss of consciousness in other animals, such as the accelerations experienced by jet pilots during extreme manoeuvres, and they make the strikes faster than the sensory and motor responses of mammalian prey and predators. Both harmless and venomous snakes can strike faster than the blink of an eye and often reach a target before it can move. © 2016 The Author(s).

  16. Tensile test and interface retention forces between wires and composites in lingual fixed retainers.

    Science.gov (United States)

    Paolone, Maria Giacinta; Kaitsas, Roberto; Obach, Patricia; Kaitsas, Vasilios; Benedicenti, Stefano; Sorrenti, Eugenio; Barberi, Fabrizio

    2015-06-01

    In daily orthodontic clinical practice retention is very important, and lingual retainers are part of this challenge. The failure of lingual retainers may be due to many factors. The aim of this study was to assess the retention forces and mechanical behavior of different types of wires matched with different kinds of composites in lingual retainers. A tensile test was performed on cylindrical composite test specimens bonded to orthodontic wires. The specimens were constructed using four different wires: a straight wire (Remanium .016×.022″ Dentaurum), two round twisted wires (Penta One .0215″ Masel, Gold Penta Twisted .0215″ Gold N'braces) and a rectangular braided wire (D-Rect .016×.022″ Ormco); and three composites: two micro-hybrids (Micro-Hybrid Enamel Plus HFO Micerium, and Micro-Hybrid SDR U Dentsply) and a micro-nano-filled composite (Micro-Nano-Filled Transbond LR 3M). The test was performed at a speed of 10mm/min on an Inström device. The wire was fixed with a clamp. The results showed that the bonding between wires and composites in lingual fixed retainers seemed to be lowest for rectangular smooth wires and increased in round twisted and rectangular twisted wires where the bonding was so strong that the maximum tension/bond strength was greater than the ultimate tensile strength of the wire. The highest values were in rectangular twisted wires. Concerning the composites, hybrid composites had the lowest interface bonding values and broke very quickly, while the nano- and micro-composites tolerated stronger forces and displayed higher bonding values. The best results were observed with the golden twisted wire and reached 21.46 MPa with the Transbond composite. With the rectangular braided wire the retention forces were so high that the Enamel Plus composite fractured when the load exceeded 154.6 N/MPa. When the same wire was combined with the Transbond LR either the wire or the composite broke when the force exceeded 240 N. The results of this

  17. Put Your Cable Wiring to the Test.

    Science.gov (United States)

    Day, C. William

    2001-01-01

    Discusses why schools and universities should use testing procedures in any wire bid specification for cable wiring and also know how experienced the installers are in testing and installing structured cabling systems. Key cabling terms are included. (GR)

  18. Strong Algerian Earthquake Strikes Near Capital City

    Science.gov (United States)

    Ayadi, A.; Maouche, S.; Harbi, A.; Meghraoui, M.; Beldjoudi, H.; Oussadou, F.; Mahsas, A.; Benouar, D.; Heddar, A.; Rouchiche, Y.; Kherroubi, A.; Frogneux, M.; Lammali, K.; Benhamouda, F.; Sebaï, A.; Bourouis, S.; Alasset, P. J.; Aoudia, A.; Cakir, Z.; Merahi, M.; Nouar, O.; Yelles, A.; Bellik, A.; Briole, P.; Charade, O.; Thouvenot, F.; Semane, F.; Ferkoul, A.; Deramchi, A.; Haned, S. A.

    On 21 May 2003, a damaging earthquake of Mw 6.8 struck the region of Boumerdes 40 km east of Algiers in northern Algeria (Figure 1). The mainshock, which lasted ~ 36-40 s, had devastating effects and claimed about 2300 victims, caused more than 11,450 injuries, and left about 200,000 people homeless. It destroyed and seriously damaged around 180,000 housing units and 6000 public buildings with losses estimated at $5 billion. The mainshock was widely felt within a radius of ~ 400 km in Algeria. To the north, the earthquake was felt in southeastern Spain, including the Balearic Islands, and also in Sardinia and in southern France. The mainshock location, which was calculated at 36.91°N, 3.58°E (15 km offshore of Zemmouri; Figure 1), and the local magnitude (Md 6.4) are from seismic records of local stations. International seismological centers obtained Mw 6.8 (NEIC) with a thrust focal mechanism solution and 1.83 × 1026 dyne.cm for the seismic moment. A sequence of aftershocks affected the epicentral area with two strong shocks reaching Mw 5.8 on 27 and 29 May 2003. Field investigations allowed us to assign a maximum intensity X (European Macroseismic Scale 98) and to report rockfalls, minor surface cracks, and liquefaction phenomena. The mainshock was not associated with inland surface faulting, but one of the most striking coseismic effects is the coastal uplift and the backwash along the littoral of the Mitidja basin.

  19. Novel Wiring Technologies for Aerospace Applications

    Science.gov (United States)

    Gibson, Tracy L.; Parrish, Lewis M.

    2014-01-01

    Because wire failure in aerospace vehicles could be catastrophic, smart wiring capabilities have been critical for NASA. Through the years, researchers at Kennedy Space Center (KSC) have developed technologies, expertise, and research facilities to meet this need. In addition to aerospace applications, NASA has applied its knowledge of smart wiring, including self-healing materials, to serve the aviation industry. This webinar will discuss the development efforts of several wiring technologies at KSC and provide insight into both current and future research objectives.

  20. Clinical bending of nickel titanium wires

    OpenAIRE

    Stephen Chain; Priyank Seth; Namrata Rastogi; Kenneth Tan; Mayank Gupta; Richa Singh

    2015-01-01

    Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our invento...

  1. Towards Unconventional Applications of Wire Bonding

    OpenAIRE

    Schröder, Stephan

    2018-01-01

    This thesis presents novel heterogeneous integration approaches of wire materials to fabricated and package MEMS devices by exploring unconventional applications of wire bonding technology. Wire bonding, traditionally endemic in the realm of device packaging to establish electrical die-to-package interconnections, is an attractive back-end technology, offering promising features, such as high throughput, flexibility and placement accuracy. Exploiting the advantages of state-of-the-art wire bo...

  2. Different mechanical properties in Seldinger guide wires

    Directory of Open Access Journals (Sweden)

    Wolfram Schummer

    2015-01-01

    Full Text Available Background and Aims: Most central venous catheters are placed using Seldinger guide wires. EN ISO 11070 is the guideline for testing guide wire flexing performance and tensile strength, and we can safely assume that guide wires in use meet these requirements. Unfortunately, EN ISO 11070 guidelines do not reflect the clinical requirements and we continue to see mechanical failures and their associated complications. Material and Methods: This in vitro study was performed in an accredited laboratory. With regard to flexing, we: (1 Established the minimum flexing performance needed to meet clinical requirements, (2 developed flexing performance tests which mimic clinical requirement, and (3 evaluated the mechanical properties of various guide wires relative to these requirements. With regard to tensile strength, we used the testing method prescribed in ISO 11070, but did not end the test at 5 Newton (N. We continued until the guide wire was damaged, or we reached maximum tractive force. We then did a wire-to-wire comparison. We examined two basic wire constructions, monofil and core and coil. Results: Tensile strength: All wires tested, except one, met EN ISO 11070 requirements for 5 N tensile strength. The mean of the wire types tested ranged from 15.06 N to 257.76 N. Flexing performance: None of the wires kinked. The monofil had no evidence of bending. Two core/coil wires displayed minor bending (angle 1.5°. All other wires displayed bending angles between 22.5° and 43.0°. Conclusion: We recommend that: (1 Clinicians use guide wires with high-end mechanical properties, (2 EN ISO 11070 incorporate our flexing test into their testing method, raise the flexing requirement to kink-proof, (3 and raise the tensile strength requirement to a minimum of 30 N, and (3 all manufacturers and suppliers be required to display mechanical properties of all guide wire, and guide wire kits sold.

  3. Vocational Preparation Curriculum: Electrical Wiring.

    Science.gov (United States)

    Usoro, Hogan

    This document is a curriculum guide for instructors teaching vocational preparation for electrical wiring to special needs students. The purpose of the curriculum guide is to provide minimum skills for disadvantaged and handicapped students entering the mainstream; to supplement vocational skills of those students already in a regular training…

  4. Transparency in nanophotonic quantum wires

    International Nuclear Information System (INIS)

    Singh, Mahi R

    2009-01-01

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  5. Health care's 100 most wired.

    Science.gov (United States)

    Solovy, A; Serb, C

    1999-02-01

    They're wired all right, and America's 100 most techno-savvy hospitals and health systems share one more thing: a commitment to using technology to link with employees, patients, suppliers, and insurers. "We want to be a health care travel agency for our community," says one chief information officer. "And we see Internet technology as a key."

  6. Autoclaving and clinical recycling: effects on mechanical properties of orthodontic wires.

    Science.gov (United States)

    Oshagh, M; Hematiyan, M R; Mohandes, Y; Oshagh, M R; Pishbin, L

    2012-01-01

    About half of the orthodontists recycle and reuse orthodontic wires because of their costs. So when talking about reuse and sterilization of wires, their effects on mechanical properties of wires should be clarified. The purpose of this study was to assess the effects of sterilization and clinical use on mechanical properties of stainless steel wires. Thirty stainless steel orthodontic wires were divided into three equal groups of control, autoclave (sterilized by autoclave), and recycle group (wires were used for orthodontic patients up to 4 weeks, cleaned by isopropyl alcohol and sterilized by autoclave). The mechanical properties (tensile test, three-point loading test for load-deflection curve) were determined. Fracture force, yield strength, stiffness and modulus of elasticity in recycle groups were significantly lower than the other groups (P < 0.05). Although recycle wires were softer than those of control group, relatively small differences and also various properties of available wires have obscured the clinical predictability of their application. There is seemingly no problem in terms of mechanical properties to recycle orthodontic wires.

  7. Multi-anode wire straw tube tracker

    International Nuclear Information System (INIS)

    Oh, S.H.; Ebenstein, W.L.; Wang, C.W.

    2011-01-01

    We report on a test of a straw tube detector design having several anode (sense) wires inside a straw tube. The anode wires form a circle inside the tube and are read out independently. This design could solve several shortcomings of the traditional single wire straw tube design such as double hit capability and stereo configuration.

  8. Home and School Technology: Wired versus Wireless.

    Science.gov (United States)

    Van Horn, Royal

    2001-01-01

    Presents results of informal research on smart homes and appliances, structured home wiring, whole-house audio/video distribution, hybrid cable, and wireless networks. Computer network wiring is tricky to install unless all-in-one jacketed cable is used. Wireless phones help installers avoid pre-wiring problems in homes and schools. (MLH)

  9. On the preparation of superconducting wires

    International Nuclear Information System (INIS)

    Topare, R.J.; Chinchure, A.D.; Shah, S.S.; Hadole, G.B.

    1993-01-01

    The different methods of preparation of superconducting wires have been discussed. The powder-in-tube technique is followed for the preparation of YBCO and BISCCO superconducting wires. The results are discussed. The present status of the industries in preparing the superconducting wires having the maximum J c values is discussed. (author). 30 refs., 6 figs., 2 tabs

  10. Pre-wired systems prove their worth.

    Science.gov (United States)

    2012-03-01

    The 'new generation' of modular wiring systems from Apex Wiring Solutions have been specified for two of the world's foremost teaching hospitals - the Royal London and St Bartholomew's Hospital, as part of a pounds sterling 1 billion redevelopment project, to cut electrical installation times, reduce on-site waste, and provide a pre-wired, factory-tested, power and lighting system. HEJ reports.

  11. 75 FR 4584 - Wire Decking From China

    Science.gov (United States)

    2010-01-28

    ... COMMISSION Wire Decking From China AGENCY: United States International Trade Commission. ACTION: Scheduling... retarded, by reason of subsidized and less-than-fair-value imports from China of wire decking, provided for..., producers, or exporters in China of wire decking, and that such ] products are being sold in the United...

  12. A decade of U.S. Air Force bat strikes

    Science.gov (United States)

    Peurach, Suzanne C.; Dove, Carla J.; Stepko, Laura

    2009-01-01

    From 1997 through 2007, 821 bat strikes were reported to the U.S. Air Force (USAF) Safety Center by aircraft personnel or ground crew and sent to the National Museum of Natural History, Smithsonian Institution, for identification. Many samples were identified by macroscopic and or microscopic comparisons with bat specimens housed in the museum and augmented during the last 2 years by DNA analysis. Bat remains from USAF strikes during this period were received at the museum from 40 states in the United States and from 20 countries. We confirmed that 46% of the strikes were caused by bats, but we did not identify them further; we identified 5% only to the family or genus level, and 49% to the species level. Fifty-five of the 101 bat-strike samples submitted for DNA analysis have been identified to the species level. Twenty-five bat species have been recorded striking USAF planes worldwide. The Brazilian free-tailed bat (Tadarida brasiliensis; n = 173) is the species most commonly identified in USAF strike impacts, followed by the red bat (Lasiurus borealis; n = 83). Bat strikes peak during the spring and fall, with >57% occurring from August through October; 82% of the reports that included time of strike were recorded between 2100 and 0900 hours. More than 12% of the bat strikes were reported at >300 m above ground level (AGL). Although $825,000 and >50% of this sum was attributable to 5 bat-strike incidents. Only 5 bats from the 10 most damaging bat strikes were identified to the species level, either because we did not receive remains with the reports or the sample was insufficient for identification.

  13. Actual and perceived collision risk for bird strikes at Namibian airports

    African Journals Online (AJOL)

    At Namibia's two major airports, Hosea Kutako International and Eros (domestic), 117 bird strike collision incidents were recorded between 2006 and 2010. A risk assessment, which included a proposed risk weighting methodology, was conducted at Hosea Kutako and Eros airports, which estimated the probability of an ...

  14. Final Environmental Assessment for Conventional Strike Missile Demonstration

    Science.gov (United States)

    2010-08-11

    MMPA Pygmy killer whale Feresa attenuata MMPA Dwarf sperm whale Kogia sima MMPA Pygmy sperm whale Kogia breviceps MMPA Melon -headed whale...macrorhynchus MMPA Melon Headed Whale Peponocephala electra MMPA Pygmy Killer Whale Feresa attenuata MMPA Killer Whale Orcinus orca MMPA Blainville’s...American butterflies. El Segundo blue butterfly adults mate, nectar , lay eggs, perch, and in most cases probably die on flower heads (Mattoni 1990

  15. Initial arch wires for alignment of crooked teeth with fixed orthodontic braces.

    Science.gov (United States)

    Wang, Yan; Jian, Fan; Lai, Wenli; Zhao, Zhihe; Yang, Zhi; Liao, Zhengyu; Shi, Zongdao; Wu, Taixiang; Millett, Declan T; McIntyre, Grant T; Hickman, Joy

    2010-04-14

    The initial arch wire is the first arch wire to be inserted into the fixed appliance at the beginning of orthodontic treatment and is used mainly for correcting crowding and rotations of teeth. With a number of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. To identify and assess the evidence for the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (30th November 2009), CENTRAL (The Cochrane Library 2009, Issue 4), MEDLINE (1950 to 30th November 2009) and EMBASE (1980 to 30th November 2009). Reference lists of articles were also searched. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies. Randomised controlled trials (RCTs) of initial arch wires to align crooked teeth with fixed orthodontic braces were selected. Only studies involving patients with upper and/or lower full arch fixed orthodontic appliances were included. Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information. Seven RCTs, with 517 participants, provided data for this review. Among them, five trials investigated the speed of initial tooth alignment comparing: 0.016 inch ion-implanted A-NiTi wire versus 0.016 inch A-NiTi versus 0.0175 multistrand stainless steel wire; 0.016x0.022 inch medium force active M-NiTi wire versus 0.016x0.022 inch graded force active M-NiTi wire versus 0.0155 inch multistrand

  16. Thermite welding of Cu-Nb microcomposite wires

    Energy Technology Data Exchange (ETDEWEB)

    Visniakov, Nikolaj; Mikalauskas, Gediminas; Lukauskaite, Raimonda; Cernasejus, Olegas; Rudzinskas, Vitalijus [Vilnius Gediminas Technical Univ. (Lithuania). Faculty of Mechanics; Skamat, Jelena; Boris, Renata [Vilnius Gediminas Technical Univ. (Lithuania). Inst. of Thermal Insulation

    2017-10-15

    Thermite welding of Cu-Nb microcomposite wires was investigated. Suitable compositions of thermite material and slag were determined from the equation of the exothermic combustion synthesis reaction. The phase compositions of the thermite mixture and slag determined by X-ray diffraction analysis correspond to those assessed from the equation. According to non-destructive radiographic testing, the joint structure does not have welding defects. Microstructural examination of the joint cross-section with scanning electron microscopy showed that the Cu-Nb wire retained its shape and microstructure and only a thin surface layer of wire was melted during welding. The difference in electrical resistances of the conductor and welded joint was below 20 %. The thermite joint can withstand a maximum load equal to 62.5 % of the load-bearing capacity of microcomposite conductor.

  17. Reporting the Great Railroad Strike: How Ideology Shaped the News.

    Science.gov (United States)

    Coward, John

    The Great Railroad Strike of 1877, a national catastrophe and the major news story of the year, was the first national labor strike in U.S. history. Because of the ideological bias of the press, specifically its implicit commitment to capitalism and to objectivity (itself a "myth" of social order), newspapers of the period could be…

  18. The public's attitude towards strike action by healthcare workers and ...

    African Journals Online (AJOL)

    The strength of the associations was determined by Cramer's V. Results. Results revealed strong opinions among the population regarding strikes, numerous misapprehensions when it comes to striking and rights, a poor awareness of other healthcare-related rights and the perception of poor treatment at public hospitals.

  19. Teaching Striking Skills in Elementary Physical Education Using Woodball

    Science.gov (United States)

    Chang, Seung Ho; Lee, Jihyun

    2017-01-01

    Object control (OC) skills are a part of fundamental motor skills and basic functional skills, which work as a prerequisite to becoming a skilled performer in many sports. Of various OC skills, striking is one of the most difficult to master due to a variety of interrelated movement components. A form of vertical or underarm striking is a more…

  20. LAW AND ETHICS OF STRIKES IN THE NIGERIAN HEALTH SYSTEM

    African Journals Online (AJOL)

    2014-10-06

    Oct 6, 2014 ... employment. Kidnapping has been affecting virtually every sector of the Nigerian economy. Thus it is not the right of any health worker to embark on strike. Rather the right to strike can be derived from the principle of collective bargaining, which according to Ahmed (2014) is an essential principle. Workers ...

  1. Ban on right to strike by police challenged

    NARCIS (Netherlands)

    Grünell, M.

    2008-01-01

    After months of negotiation between the police force and the minister of the interior on the renewal of the collective agreement, the police trade unions began threatening industrial action and strikes in December 2007. The courts were divided on the issue, with some ruling out strikes as a means of

  2. Martial arts striking hand peak acceleration, accuracy and consistency.

    Science.gov (United States)

    Neto, Osmar Pinto; Marzullo, Ana Carolina De Miranda; Bolander, Richard P; Bir, Cynthia A

    2013-01-01

    The goal of this paper was to investigate the possible trade-off between peak hand acceleration and accuracy and consistency of hand strikes performed by martial artists of different training experiences. Ten male martial artists with training experience ranging from one to nine years volunteered to participate in the experiment. Each participant performed 12 maximum effort goal-directed strikes. Hand acceleration during the strikes was obtained using a tri-axial accelerometer block. A pressure sensor matrix was used to determine the accuracy and consistency of the strikes. Accuracy was estimated by the radial distance between the centroid of each subject's 12 strikes and the target, whereas consistency was estimated by the square root of the 12 strikes mean squared distance from their centroid. We found that training experience was significantly correlated to hand peak acceleration prior to impact (r(2)=0.456, p =0.032) and accuracy (r(2)=0. 621, p=0.012). These correlations suggest that more experienced participants exhibited higher hand peak accelerations and at the same time were more accurate. Training experience, however, was not correlated to consistency (r(2)=0.085, p=0.413). Overall, our results suggest that martial arts training may lead practitioners to achieve higher striking hand accelerations with better accuracy and no change in striking consistency.

  3. Power electromagnetic strike machine for engineering-geological surveys

    Science.gov (United States)

    Usanov, K. M.; Volgin, A. V.; Chetverikov, E. A.; Kargin, V. A.; Moiseev, A. P.; Ivanova, Z. I.

    2017-10-01

    When implementing the processes of dynamic sensing of soils and pulsed nonexplosive seismic exploration, the most common and effective method is the strike one, which is provided by a variety of structure and parameters of pneumatic, hydraulic, electrical machines of strike action. The creation of compact portable strike machines which do not require transportation and use of mechanized means is important. A promising direction in the development of strike machines is the use of pulsed electromagnetic actuator characterized by relatively low energy consumption, relatively high specific performance and efficiency, and providing direct conversion of electrical energy into mechanical work of strike mass with linear movement trajectory. The results of these studies allowed establishing on the basis of linear electromagnetic motors the electromagnetic pulse machines with portable performance for dynamic sensing of soils and land seismic pulse of small depths.

  4. Clinical bending of nickel titanium wires

    Directory of Open Access Journals (Sweden)

    Stephen Chain

    2015-01-01

    Full Text Available Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our inventory but also customized the wire according to the treatment.

  5. Emittance growth due to Tevatron flying wires

    Energy Technology Data Exchange (ETDEWEB)

    Syphers, M; Eddy, Nathan

    2004-06-01

    During Tevatron injection, Flying Wires have been used to measure the transverse beam size after each transfer from the Main Injector in order to deduce the transverse emittances of the proton and antiproton beams. This amounts to 36 + 9 = 45 flies of each of 3 wire systems, with an individual wire passing through each beam bunch twice during a single ''fly''. below they estimate the emittance growth induced by the interaction of the wires with the particles during these measurements. Changes of emittance from Flying Wire measurements conducted during three recent stores are compared with the estimations.

  6. The wiring economy principle: connectivity determines anatomy in the human brain.

    Science.gov (United States)

    Raj, Ashish; Chen, Yu-hsien

    2011-01-01

    Minimization of the wiring cost of white matter fibers in the human brain appears to be an organizational principle. We investigate this aspect in the human brain using whole brain connectivity networks extracted from high resolution diffusion MRI data of 14 normal volunteers. We specifically address the question of whether brain anatomy determines its connectivity or vice versa. Unlike previous studies we use weighted networks, where connections between cortical nodes are real-valued rather than binary off-on connections. In one set of analyses we found that the connectivity structure of the brain has near optimal wiring cost compared to random networks with the same number of edges, degree distribution and edge weight distribution. A specifically designed minimization routine could not find cheaper wiring without significantly degrading network performance. In another set of analyses we kept the observed brain network topology and connectivity but allowed nodes to freely move on a 3D manifold topologically identical to the brain. An efficient minimization routine was written to find the lowest wiring cost configuration. We found that beginning from any random configuration, the nodes invariably arrange themselves in a configuration with a striking resemblance to the brain. This confirms the widely held but poorly tested claim that wiring economy is a driving principle of the brain. Intriguingly, our results also suggest that the brain mainly optimizes for the most desirable network connectivity, and the observed brain anatomy is merely a result of this optimization.

  7. A New Superconducting Wire for Future Accelerators

    CERN Multimedia

    2006-01-01

    The CARE/NED project has developed a new superconducting wire that can achieve very high currents (1400 amps) at high magnetic fields (12 teslas). Cross-section of the CARE/NED wire produced by SMI. As we prepare to enter a new phase of particle physics with the LHC, technological development is a continuous process to ensure the demands of future research are met. The next generation of colliders and upgrades of the present ones will require significantly larger magnetic fields for bending and focusing the particle beams. NED (Next European Dipole) is one of the projects taking on this challenge to push technology beyond the present limit (see: More about NED). The magnets in the LHC rely on niobium titanium (NbTi) as the superconducting material, with a maximum magnetic field of 8 to 10T (tesla). In order to exceed this limitation, a different material together with the corresponding technology needs to be developed. NED is assessing the suitability of niobium tin (Nb3Sn), which has the potential to at le...

  8. Vibrating wire for beam profile scanning

    Directory of Open Access Journals (Sweden)

    S. G. Arutunian

    1999-12-01

    Full Text Available A method that measures the transverse profile (emittance of the bunch by detecting radiation arising at the scattering of the bunch on scanning wire is widely used. In this work information about bunch scattering is obtained by measuring the oscillation frequency of the tightened scanning wire. In such a way, the system of radiation (or secondary particles extraction and measurement can be removed. The entire unit consists of a compact fork with tightened wire and a scanning system. Normal oscillation frequency of a wire depends on wire tension, its geometric parameters, and, in a second approximation, its elastic characteristics. Normal oscillations are generated by interaction of an alternating current through the wire with magnetic field of a permanent magnet. In this case, it is suggested that the magnetic field of the accelerator (field of dipole magnets or quadrupole magnets be used for excitation of oscillations. The dependence of oscillation frequency on beam scattering is determined by several factors, including changes of wire tension caused by transverse force of the beam and influence of beam self-field. Preliminary calculations show that the influence of wire heating will dominate. We have studied strain gauges on the basis of vibrating wire from various materials (tungsten, beryl bronze, and niobium zirconium alloys. A scheme of normal oscillation generation by alternating current in autogeneration circuit with automatic frequency adjustment was selected. A special method of wire fixation and elimination of transverse degrees of freedom allows us to achieve relative stability better than 10^{-5} during several days at a relative resolution of 10^{-6}. Experimental results and estimates of wire heating of existing scanners show that the wire heats up to a few hundred grades, which is enough for measurements. The usage of wire of micrometer thickness diminishes the problem of wire thermalization speed during the scanning of the bunch.

  9. Modifications in straight wire treatment.

    Science.gov (United States)

    Cardona, Alvin

    2010-01-01

    Orthodontic treatments have been modified with each new generation of clinicians. Today the emphasis is on facial esthetics and healthy temporomandibular joints. With orthopedic treatment, we can develop dental arches to get the necessary space to align the teeth and we can reach adequate function and esthetics, all within relatively good stability. By combining two-phase treatment with low friction fixed orthodontics and super elastic wires we produce light but continuous forces and we can provide better treatment than before. These types of forces cause physiological and functional orthopedic orthodontic reactions. The purpose of this article is to demonstrate our fixed orthopedic and orthodontic approach called "Modified Straight Wire" or "Physiologic Arch Technique." This technique is very successful with our patients because it can exert slow and continuous forces with minimal patient cooperation.

  10. Sintered wire cesium dispenser photocathode

    Science.gov (United States)

    Montgomery, Eric J; Ives, R. Lawrence; Falce, Louis R

    2014-03-04

    A photoelectric cathode has a work function lowering material such as cesium placed into an enclosure which couples a thermal energy from a heater to the work function lowering material. The enclosure directs the work function lowering material in vapor form through a low diffusion layer, through a free space layer, and through a uniform porosity layer, one side of which also forms a photoelectric cathode surface. The low diffusion layer may be formed from sintered powdered metal, such as tungsten, and the uniform porosity layer may be formed from wires which are sintered together to form pores between the wires which are continuous from the a back surface to a front surface which is also the photoelectric surface.

  11. Slice of LHC dipole wiring

    CERN Multimedia

    Dipole model slice made in 1994 by Ansaldo. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. 50’000 tonnes of steel sheets are used to make the magnet yokes that keep the wiring firmly in place. The yokes constitute approximately 80% of the accelerator's weight and, placed side by side, stretch over 20 km!

  12. Pin Wire Coating Trip Report

    International Nuclear Information System (INIS)

    Spellman, G P

    2004-01-01

    A meeting to discuss the current pin wire coating problems was held at the Reynolds plant in Los Angeles on 2MAR04. The attendance list for Reynolds personnel is attached. there was an initial presentation which gave a brief history and the current status of pin wire coating at Reynolds. There was a presentation by Lori Primus on the requirements and issues for the coating. There was a presentation by Jim Smith of LANL on the chemistry and to some extent process development done to date. There was a long session covering what steps should be taken in the short term and, to a lesser extent, the long term. The coating currently being used is a blend of two polymers, polyethersulfone and polyparabanic acid (PPA) and some TiO2 filler. This system was accepted and put into production when the pin wire coating was outsourced to another company in 1974. When that company no longer was interested, the wire coating was brought in-house to Reynolds. At that time polyparabanic acid was actually a commercial product available from Exxon under the trade name Tradlon. However, it appears that the material used at Reynolds was synthesized locally. Also, it appears that a single large batch was synthesized in that time period and used up to 1997 when the supply ran out. The reason for the inclusion of TiO2 is not known although it does act as a rheological thickener. However, a more controlled thickening can be obtained with materials such as fumed silica. This material would have less likelihood of causing point imperfections in the coatings. Also, the mixing technique being used for all stages of the process is a relatively low shear ball mill process and the author recommends a high shear process such as a three roll paint mill, at least for the final mixing. Since solvent is added to the powder at Reynolds, it may be that they need to have the paint mill there

  13. Wear of dragline wire ropes

    Energy Technology Data Exchange (ETDEWEB)

    Dayawansa, D.; Kuruppu, M.; Mashiri, F.; Bartosiewicz, H. [Monash University (Caulfield Campus), Caulfield East, Vic. (Australia). Department of Mechanical Engineering,

    2005-07-01

    Wire ropes are one of the most heavily used components in a dragline. Hoist ropes are subjected to fatigue due to the cyclic nature of load handling as well as due to rope bending over the sheaves and the drum under load. This leads to wire breaks due to fatigue. Accumulation of a number of wire breaks close to each other can have a detrimental effect on the rope. Furthermore, to allow for the increasing demand for higher load capacity coupled with the inconvenience of having very large ropes, the factor of safety is often compromised, which increases the wear rate. Drag ropes are also subjected to heavy loads. More importantly, they are allowed to drag along the rough mine surface subjecting them to external physical abrasion. This makes the life of drag ropes one of the lowest among those used in a dragline. Suspension and IBS ropes are relatively uniformly loaded during their regular usage although they need to withstand dynamic load cycles as well as bending. Hence they tend to last for a number of years on average. The paper analyses the wear types and their severity of each of these rope applications, and suggests methods to determine rope wear rates and the resulting rope life. The paper further gives suggestions for good operating and maintenance practice that can extend the rope life and help reduce the large expenditure associated with every major rope change in a dragline. 6 refs., 8 figs., 1 tab.

  14. Strikes by physicians: a historical perspective toward an ethical evaluation.

    Science.gov (United States)

    Thompson, Stephen L; Salmon, J Warren

    2006-01-01

    Current conditions surrounding the house of medicine-including corporate and government cost-containment strategies, increasing market-penetration schemes in health care, along with clinical scrutiny and the administrative control imposed under privatization by managed care firms, insurance companies, and governments-have spurred an upsurge in physician unionization, which requires a revisiting of the issue of physician strikes. Strikes by physicians have been relatively rare events in medical history. When they have occurred, they have aroused intense debate over their ethical justification among professionals and the public alike, notwithstanding what caused the strikes. As physicians and other health care providers increasingly find employment within organizations as wage-contract employees and their work becomes more highly rationalized, more physicians will join labor organizations to protect both their economic and their professional interests. As a result, these physicians will have to come to terms with the use of the strike weapon. On the surface, many health care strikes may not ever seem justifiable, but in certain defined situations a strike would be not only permissible but an ethical imperative. With an exacerbation of labor strife in the health sector in many nations, it is crucial to explore the question of what constitutes an ethical physician strike.

  15. Determine the Foot Strike Pattern Using Inertial Sensors

    Directory of Open Access Journals (Sweden)

    Tzyy-Yuang Shiang

    2016-01-01

    Full Text Available From biomechanical point of view, strike pattern plays an important role in preventing potential injury risk in running. Traditionally, strike pattern determination was conducted by using 3D motion analysis system with cameras. However, the procedure is costly and not convenient. With the rapid development of technology, sensors have been applied in sport science field lately. Therefore, this study was designed to determine the algorithm that can identify landing strategies with a wearable sensor. Six healthy male participants were recruited to perform heel and forefoot strike strategies at 7, 10, and 13 km/h speeds. The kinematic data were collected by Vicon 3D motion analysis system and 2 inertial measurement units (IMU attached on the dorsal side of both shoes. The data of each foot strike were gathered for pitch angle and strike index analysis. Comparing the strike index from IMU with the pitch angle from Vicon system, our results showed that both signals exhibited highly correlated changes between different strike patterns in the sagittal plane (r=0.98. Based on the findings, the IMU sensors showed potential capabilities and could be extended beyond the context of sport science to other fields, including clinical applications.

  16. Evaluation of Microbial Contamination of Different Orthodontic as Received Arch Wires from Manufacturers

    Directory of Open Access Journals (Sweden)

    Hassan Suha Saad

    2017-12-01

    Full Text Available Aims of study: The present study was carried out to assess whether as received arch wires from manufactures are free of microbial contamination as well as to identify the bacterial count and types attached to arch wires. Materials and Methods: Eighty samples were included in this study consisting of two types of arch wires (nitinol and stainlesssteel; they were from four companies (3 M, Ortho-Technology, Jiscop and G&H. The wires were inserted into plane tubes that contain 10 ml of BHI broth and tris-EDTA. Further 0.1 ml was withdrawn from plane tube and spread on agar plates. Moreover 16 plane tubes (8 tubes with brain heart infusion broth and 8 with tris-EDTA without arch wires were considered as controls group. Results: Microbial sampling yielded growth from 7 of the 80 arch wires studied, the predominant bacteria isolated were staphylococci spp. No growth was recovered from 73 of the samples and from controls. The total viable count of bacteria in BHI reagent is more than that in Tris-EDTA reagent with statistically significant difference (P0.05. In regard to the presence and distribution of bacteria according to types of wires, the stainless-steel wires have more viable count (49.58 than that in nitinol (47.42 but statistically not significant (P0.05. Conclusion: The arch wires received from manufacturer are often contaminated and therefore there is a need for routine disinfection of such items. This study found that the BHI more is effective in dislodging the bacteria from orthodontic arch wires than tris- EDTA. However, the stainless-steel arch wires were more contaminated than nitinol and most common contaminant were Staphylococci spp

  17. A comparative study of bio degradation of various orthodontic arch wires: an in vitro study.

    Science.gov (United States)

    Gopikrishnan, S; Melath, Anil; Ajith, V V; Mathews, N Binoy

    2015-01-01

    Orthodontic wires are the corner stones of the science and art of orthodontics and they remain in the patient's mouth for a prolonged period of 18-24 months. It is but natural to expect that they will undergo some biodegradation when in the oral environment during that period. This study aims to compare the biodegradation characteristics of four different orthodontic wires, stainless steel, nickel titanium (NiTi), titanium molybdenum alloy (TMA), and copper NiTi and to assess whether these biodegradation products, are within acceptable limits. This study involved the incubation of four different wires in artificial saliva and analyzing the amount of metal released from them at the end of a 28 days study period. The metals analyzed for where nickel, chromium, copper, cobalt, manganese, iron, molybdenum, and titanium. The artificial saliva was changed on days 7, 14, and 21 to prevent the saturation of metals in the artificial saliva. At the end of 28 days, these four samples of artificial saliva of each wire were mixed together and analyzed for the eight metals using an inductively coupled plasma spectroscope. The results showed only the release of nickel, chromium, and iron from stainless steel wire, nickel from NiTi wire, nickel, and chromium from copper NiTi and none from TMA wire. The metals released from arch wires are of such minute quantities to be of any biologic hazard. The amount of metals released is well within acceptable biocompatible limits. Though this study has analyzed the biodegradation of various orthodontic wires, orthodontic wires are never used alone in mechanotherapy. Orthodontic wires along with multiband appliance system with which it is always used and in combination with accessories like face bows may release more metals.

  18. Ankle and knee kinetics between strike patterns at common training speeds in competitive male runners.

    Science.gov (United States)

    Kuhman, Daniel; Melcher, Daniel; Paquette, Max R

    2016-01-01

    The purpose of this study was to investigate the interaction of foot strike and common speeds on sagittal plane ankle and knee joint kinetics in competitive rear foot strike (RFS) runners when running with a RFS pattern and an imposed forefoot strike (FFS) pattern. Sixteen competitive habitual male RFS runners ran at two different speeds (i.e. 8 and 6 min mile(-1)) using their habitual RFS and an imposed FFS pattern. A repeated measures analysis of variance was used to assess a potential interaction between strike pattern and speed for selected ground reaction force (GRF) variables and, sagittal plane ankle and knee kinematic and kinetic variables. No foot strike and speed interaction was observed for any of the kinetic variables. Habitual RFS yielded a greater loading rate of the vertical GRF, peak ankle dorsiflexor moment, peak knee extensor moment, peak knee eccentric extensor power, peak dorsiflexion and sagittal plane knee range of motion compared to imposed FFS. Imposed FFS yielded greater maximum vertical GRF, peak ankle plantarflexor moment, peak ankle eccentric plantarflexor power and sagittal plane ankle ROM compared to habitual RFS. Consistent with previous literature, imposed FFS in habitual RFS reduces eccentric knee extensor and ankle dorsiflexor involvement but produce greater eccentric ankle plantarflexor action compared to RFS. These acute differences between strike patterns were independent of running speeds equivalent to typical easy and hard training runs in competitive male runners. Current findings along with previous literature suggest differences in lower extremity kinetics between habitual RFS and imposed FFS running are consistent among a variety of runner populations.

  19. Mechanical and Electrical Properties of Palladium-Coated Copper Wires with Flash Gold

    Science.gov (United States)

    Chang, Chia-Yun; Hung, Fei-Yi; Lui, Truan-Sheng

    2017-07-01

    Palladium-coated copper wire with flash gold (PCA) is a fine wire with an oxidation resistance layer. A new sulfidation test has been assessed in this work, confirming that PCA wires show better sulfidation corrosion resistance than either palladium-coated or bare copper wires. The sulfided surface of PCA was analyzed, along with its bonding strength and electrical properties. The metallurgic mechanism for formation of free air balls during the electric flame-off (EFO) process was identified. The flash gold layer of PCA wires can improve certain shortcomings, including: (1) efficiently promoting sulfidation corrosion resistance, (2) solving the problem of palladium segregation during the EFO process, (3) reducing the starting voltage, and (4) stabilizing the electrical resistivity of the bonding interface.

  20. Strike action by nurses in South Africa: A value clarification

    Directory of Open Access Journals (Sweden)

    Marie Muller

    2001-09-01

    Full Text Available The Labour Relations Act (South Africa, 1991 made provision for protected strike action by employees, subject to certain conditions, procedures and negotiated agreements. This led to the removal of the strike clause in the Nursing Act (South Africa, 1992. The labour rights of all citizens are entrenched in the Constitution of the country (South Africa, 1996. Participation in strike action by the nurse/ midwife, regardless of the legal requirements and specifications, does, however, pose an ethical question. It is therefore necessary to conduct a value clarification on strike action by nurses in South Africa. The purpose of this research is to explore and describe the perceived values of participants from an accessible population on this phenomenon. A qualitative, exploratory and descriptive research design was deployed. The perceived values of nurses on strike action were collected by means of an openended questionnaire/sketch. Over a period of three years a purposive and convenient sampling method was used, involving all the enrolled post basic nursing/midwifery students/ learners at a particular Nursing Education Institution. The justification of the sample was further enhanced by also collecting data on the participants’ age and provincial distribution location. Although a 63% sample realisation (of the accessible population was achieved, this represents only 1,5% of the registered nursing/midwifery population in the country. A descriptive analysis of the participants’ age and provincial distribution was undertaken, as well as a content analysis of their perceived values on strike action. The mean age of the participants was 48 years, which could be attributed to the fact that most of them were enrolled for a post-basic Diploma in Community Nursing Science. Most of the responses (52,7% were against strike action and 32,5% supported strike action by nurses as a constitutional and legal right. A fairly substantial number of participants (14

  1. "Thunderstruck": penetrating thoracic injury from lightning strike.

    Science.gov (United States)

    van Waes, Oscar J F; van de Woestijne, Pieter C; Halm, Jens A

    2014-04-01

    Lightning strike victims are rarely presented at an emergency department. Burns are often the primary focus. This case report describes the improvised explosive device like-injury to the thorax due to lightning strike and its treatment, which has not been described prior in (kerauno)medicine. Penetrating injury due to blast from lightning strike is extremely rare. These "shrapnel" injuries should however be ruled out in all patients struck by lightning. Copyright © 2013 American College of Emergency Physicians. Published by Mosby, Inc. All rights reserved.

  2. Lower Extremity Biomechanics and Self-Reported Foot-Strike Patterns Among Runners in Traditional and Minimalist Shoes.

    Science.gov (United States)

    Goss, Donald L; Lewek, Michael; Yu, Bing; Ware, William B; Teyhen, Deydre S; Gross, Michael T

    2015-06-01

    The injury incidence rate among runners is approximately 50%. Some individuals have advocated using an anterior-foot-strike pattern to reduce ground reaction forces and injury rates that they attribute to a rear-foot-strike pattern. The proportion of minimalist shoe wearers who adopt an anterior-foot-strike pattern remains unclear. To evaluate the accuracy of self-reported foot-strike patterns, compare negative ankle- and knee-joint angular work among runners using different foot-strike patterns and wearing traditional or minimalist shoes, and describe average vertical-loading rates. Descriptive laboratory study. Research laboratory. A total of 60 healthy volunteers (37 men, 23 women; age = 34.9 ± 8.9 years, height = 1.74 ± 0.08 m, mass = 70.9 ± 13.4 kg) with more than 6 months of experience wearing traditional or minimalist shoes were instructed to classify their foot-strike patterns. Participants ran in their preferred shoes on an instrumented treadmill with 3-dimensional motion capture. Self-reported foot-strike patterns were compared with 2-dimensional video assessments. Runners were classified into 3 groups based on video assessment: traditional-shoe rear-foot strikers (TSR; n = 22), minimalist-shoe anterior-foot strikers (MSA; n = 21), and minimalist-shoe rear-foot strikers (MSR; n = 17). Ankle and knee negative angular work and average vertical-loading rates during stance phase were compared among groups. Only 41 (68.3%) runners reported foot-strike patterns that agreed with the video assessment (κ = 0.42, P shoes.

  3. Clinical Efficiency of Two Sequences of Orthodontic Wires to Correct Crowding of the Lower Anterior Teeth.

    Science.gov (United States)

    Serafim, Cláudia Maria de Castro; Gurgel, Júlio de Araújo; Tiago, Carollyne Mota; Tavarez, Rudys Rodolfo de Jesus; Maia Filho, Etevaldo Matos

    2015-01-01

    This study compared time to correction of mandibular anterior crowding using two arch wire sequences, one with conventional nickel-titanium (NiTi) arch wires and the other with conventional and NiTi heat-activated arch wires. Twenty-two boys and girls (mean age: 16.68 ± 2.66) with moderate crowding (3-6 mm) were assigned randomly to one of two groups and followed up for five months (six assessments) when arch wires were changed. Time to crowding correction was analyzed statistically using the Kaplan-Meier method. Data were collected during the five-month follow-up, and time to correction was compared between groups using the log rank test. At the end of follow-up, mandibular crowding was corrected in 100% of the cases in the group treated with the sequence that included NiTi heat-activated arch wires, whereas about 30% of those treated with NiTi arch wires were not completely corrected. There was a significant difference in time to complete treatment between groups (log rank = 5.996; p wires, alignment and leveling of mandibular anterior teeth were completed earlier than in the group treated only with conventional NiTi arch wires. Clinical trial registration is found at RBR-7g5zng.

  4. Clinical Efficiency of Two Sequences of Orthodontic Wires to Correct Crowding of the Lower Anterior Teeth

    Directory of Open Access Journals (Sweden)

    Cláudia Maria de Castro Serafim

    2015-01-01

    Full Text Available This study compared time to correction of mandibular anterior crowding using two arch wire sequences, one with conventional nickel-titanium (NiTi arch wires and the other with conventional and NiTi heat-activated arch wires. Twenty-two boys and girls (mean age: 16.68 ± 2.66 with moderate crowding (3–6 mm were assigned randomly to one of two groups and followed up for five months (six assessments when arch wires were changed. Time to crowding correction was analyzed statistically using the Kaplan-Meier method. Data were collected during the five-month follow-up, and time to correction was compared between groups using the log rank test. At the end of follow-up, mandibular crowding was corrected in 100% of the cases in the group treated with the sequence that included NiTi heat-activated arch wires, whereas about 30% of those treated with NiTi arch wires were not completely corrected. There was a significant difference in time to complete treatment between groups (log rank = 5.996; p<0.05. In the group treated with the sequence that included heat-activated wires, alignment and leveling of mandibular anterior teeth were completed earlier than in the group treated only with conventional NiTi arch wires. Clinical trial registration is found at RBR-7g5zng.

  5. A Vibrating Wire System For Quadrupole Fiducialization

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Zachary

    2010-12-13

    A vibrating wire system is being developed to fiducialize the quadrupoles between undulator segments in the LCLS. This note provides a detailed analysis of the system. The LCLS will have quadrupoles between the undulator segments to keep the electron beam focused. If the quadrupoles are not centered on the beam axis, the beam will receive transverse kicks, causing it to deviate from the undulator axis. Beam based alignment will be used to move the quadrupoles onto a straight line, but an initial, conventional alignment must place the quadrupole centers on a straight line to 100 {micro}m. In the fiducialization step of the initial alignment, the position of the center of the quadrupole is measured relative to tooling balls on the outside of the quadrupole. The alignment crews then use the tooling balls to place the magnet in the tunnel. The required error on the location of the quadrupole center relative to the tooling balls must be less than 25 {micro}m. In this note, we analyze a system under construction for the quadrupole fiducialization. The system uses the vibrating wire technique to position a wire onto the quadrupole magnetic axis. The wire position is then related to tooling balls using wire position detectors. The tooling balls on the wire position detectors are finally related to tooling balls on the quadrupole to perform the fiducialization. The total 25 {micro}m fiducialization error must be divided between these three steps. The wire must be positioned onto the quadrupole magnetic axis to within 10 {micro}m, the wire position must be measured relative to tooling balls on the wire position detectors to within 15 {micro}m, and tooling balls on the wire position detectors must be related to tooling balls on the quadrupole to within 10 {micro}m. The techniques used in these three steps will be discussed. The note begins by discussing various quadrupole fiducialization techniques used in the past and discusses why the vibrating wire technique is our method

  6. Continental United States Hurricane Strikes 1950-2012

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The Continental U.S. Hurricane Strikes Poster is our most popular poster which is updated annually. The poster includes all hurricanes that affected the U.S. since...

  7. 2005 Significant U.S. Hurricane Strikes Poster

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The 2005 Significant U.S. Hurricane Strikes poster is one of two special edition posters for the Atlantic Hurricanes. This beautiful poster contains two sets of...

  8. Ethical and legal consideration of prisoner's hunger strike in Serbia.

    Science.gov (United States)

    Alempijevic, Djordje; Pavlekic, Snezana; Jecmenica, Dragan; Nedeljkov, Aleksandra; Jankovic, Milos

    2011-03-01

    Hunger strike of prisoners and detainees remains a major human rights and ethical issue for medical professionals. We are reporting on a case of a 48-year-old male sentenced prisoner, intravenous heroin user, who went on a hunger strike and died 15 days later. Throughout the fasting period, the prisoner, who was capable of decision making, refused any medical examination. Autopsy findings were not supporting prolonged starvation, while toxicology revealed benzodiazepines and opiates in blood and urine. Cause of death was given as "heroin intoxication" in keeping with detection of 6-MAM. Legal and ethical issues pertinent to medical examination and treatment of prisoners on hunger strike are explored in accordance with legislation and professional ethical standards in Serbia. A recommendation for the best autopsy practice in deaths following hunger strike has been made. © 2011 American Academy of Forensic Sciences.

  9. Nuclear First Strike-Have the Rules Changed?

    National Research Council Canada - National Science Library

    Carter, Rosemary M

    2008-01-01

    .... Nuclear first strike is the policy that reserves the right to use nuclear weapons against an enemy before that enemy employs a like weapon without any constraints on the decision to employ the weapon...

  10. Joint Strike Fighter fit for duty in Europe?

    NARCIS (Netherlands)

    Heerkens, Johannes M.G.

    2000-01-01

    Focuses on the potential growth of the Joint Strike Fighter (JSF) market in Europe. Competition between Lockheed Martin and Boeing for the fighter's design contract; Disadvantages of the fighter plane; Stealth performance of JSF.

  11. Comparison of force, power, and striking efficiency for a Kung Fu strike performed by novice and experienced practitioners: preliminary analysis.

    Science.gov (United States)

    Neto, Osmar Pinto; Magini, Marcio; Saba, Marcelo M F; Pacheco, Marcos Tadeu Tavares

    2008-02-01

    This paper presents a comparison of force, power, and efficiency values calculated from Kung Fu Yau-Man palm strikes, when performed by 7 experienced and 6 novice men. They performed 5 palm strikes to a freestanding basketball, recorded by high-speed camera at 1000 Hz. Nonparametric comparisons and correlations showed experienced practitioners presented larger values of mean muscle force, mean impact force, mean muscle power, mean impact power, and mean striking efficiency, as is noted in evidence obtained for other martial arts. Also, an interesting result was that for experienced Kung Fu practitioners, muscle power was linearly correlated with impact power (p = .98) but not for the novice practitioners (p = .46).

  12. Measurement of wire deflection on loading may indicate union in Ilizarov constructs, an in vitro model.

    Science.gov (United States)

    Lineham, Beth; Stewart, Todd; Harwood, Paul

    2018-02-02

    No entirely reliable method exists for assessing union during Ilizarov treatment. Premature removal results in potential treatment failure; hence, alternative methods warrant investigation. Wire deflection might provide an indication of fracture site deformation on weight bearing, indicating progress towards union. This study aimed to test a method for assessing wire deflection within an Ilizarov frame. (1) To assess the repeatability of our novel measurement method in measuring wire deflection within an Ilizarov frame in vitro. (2) To compare the amount of wire deflection in an unstable model with that in an intact bone model. (3) To assess accuracy of this method by comparing wire deflection measured with overall machine extension. Tests were performed on clinical grade-tensioned fine wire 4-ring Ilizarov constructs stabilising a simulated fracture, with and without an unstable defect. Models were sequentially loaded to 700 N using an Instron testing machine. A digital depth gauge attached to the superior ring measured relative wire displacement at the ring closest to the fracture. Tests were repeated 3 times. (1) Both unstable and stable bone models produced highly repeatable load deformation curves (R 2  = 0.98 and 0.99). (2) In the unstable model, wires tensioned at 882 and 1274 N produced mean maximum deflections of 2.41 and 2.69 mm compared with 0.05 and 0.04 mm in the intact bone model (significant p measurable difference in wire deflection between stable and unstable situations exists using this method which appears accurate and repeatable, with clear correlation between displacement and load and displacement and machine extension. This approach might be clinically applicable, and further clinical testing is required.

  13. Electro-mechanics of drift tube wires

    International Nuclear Information System (INIS)

    Milburn, R.H.

    1997-01-01

    The position and stability of the sense wires in very long drift tubes are affected by both gravitational and electrostatic forces, as well as by the wire tension. For a tube to be used as an element of a high-resolution detector all these forces and their effects must be understood in appropriately precise detail. In addition, the quality control procedures applied during manufacture and detector installation must be adequate to ensure that the internal wire positions remain within tolerances. It may be instructive to practitioners to review the simple theory of a taut wire in the presence of anisotropic gravitational and electrostatic fields to illustrate the conditions for stability, the equilibrium wire displacement from straightness, and the effect of the fields on the mechanical vibration frequencies. These last may be used to monitor the wire configuration externally. A number of practical formulae result and these are applied to illustrative examples. (orig.)

  14. Electromagnetic Behaviour of Metallic Wire Structures

    CERN Document Server

    Chui, S T

    2013-01-01

    Despite the recent development and interest in the photonics of metallic wire structures, the relatively simple concepts and physics often remain obscured or poorly explained to those who do not specialize in the field. Electromagnetic Behaviour of Metallic Wire Structures provides a clear and coherent guide to understanding these phenomena without excessive numerical calculations.   Including both background material and detailed derivations of the various different formulae applied, Electromagnetic Behaviour of Metallic Wire Structures describes how to extend basic circuit theory relating to voltages, currents, and resistances of metallic wire networks to include situations where the currents are no longer spatially uniform along the wire. This lays a foundation for a deeper understanding of the many new phenomena observed in meta-electromagnetic materials.   Examples of applications are included to support this new approach making Electromagnetic Behaviour of Metallic Wire Structures a comprehensive and ...

  15. Phosphorus in antique iron music wire.

    Science.gov (United States)

    Goodway, M

    1987-05-22

    Harpsichords and other wire-strung musical instruments were made with longer strings about the beginning of the 17th century. This change required stronger music wire. Although these changes coincided with the introduction of the first mass-produced steel (iron alloyed with carbon), carbon was not found in samples of antique iron harpsichord wire. The wire contained an amount of phosphorus sufficient to have impeded its conversion to steel, and may have been drawn from iron rejected for this purpose. The method used to select pig iron for wire drawing ensured the highest possible phosphorus content at a time when its presence in iron was unsuspected. Phosphorus as an alloying element has had the reputation for making steel brittle when worked cold. Nevertheless, in replicating the antique wire, it was found that lowcarbon iron that contained 0.16 percent phosphorus was easily drawn to appropriate gauges and strengths for restringing antique harpsichords.

  16. Local avian density influences risk of mortality from window strikes

    Science.gov (United States)

    Sabo, Ann M.; Hagemeyer, Natasha D.G.; Lahey, Ally S.

    2016-01-01

    Up to a billion birds die per year in North America as a result of striking windows. Both transparent and reflective glass panes are a cause for concern, misleading birds by either acting as invisible, impenetrable barriers to desired resources, or reflecting those resources over a large surface area. A high number of window strikes occur during migration, but little is known about the factors of susceptibility, or whether particular avian taxa are more vulnerable than others. We report on a study of window strikes and mist-netting data at the Virginia Zoological Park (Norfolk, Virginia, USA), conducted in the autumn of 2013 and 2014. We focused on three factors likely to contribute to an individual’s predisposition to collide with windows: (i) taxonomic classification, (ii) age, and (iii) migrant vs. resident status. Thrushes, dominated by the partial migrant American Robin (Turdus migratorius), were significantly less likely to strike glass than be sampled in mist nets (χ2 = 9.21, p = 0.002), while wood-warblers (Parulidae) were more likely to strike than expected (χ2 = 13.55, p windows (45.4%) was not significantly different (χ2 = 0.05, p = 0.827) than the population of juvenile birds naturally occurring at the zoo (48.8%). Migrants, however, were significantly more susceptible to window strikes than residents (χ2 = 6.35, p = 0.012). Our results suggest that resident birds are able to learn to avoid and thus reduce their likelihood of striking windows; this intrinsic risk factor may help explain the apparent susceptibility of certain taxa to window strikes. PMID:27366656

  17. Calculated photon spectra at several angles for 5- and 50-MeV electron beams striking solid and gas targets

    International Nuclear Information System (INIS)

    Slaughter, D.R.

    1983-01-01

    Coupled electron-photon transport calculations have been carried out to simulate the photon generation when a 5- or 50-MeV electron beam strikes a solid or gas target. Results indicate that a 5-MeV beam striking targets of tungsten wire, air, or air doped with Kr or Xe generates a photon spectrum sharply peaked in the forward direction and with approximately 1/E spectral intensity. At right angles to the beam the photon intensity is predominantly due to characteristic K x-rays. A 50-MeV beam striking the same targets generates substantially higher photon yield in the forward direction, but the yield normal to the beam is similar to that due to the 5-MeV beam. However, positron-electron annihilation radiation constitutes a significant part of the photon radiation normal to the beam, and is more intense than characteristic K x-rays when the target is more than about one-third of the electron range

  18. NASA storm hazards research in lightning strikes to aircraft

    Science.gov (United States)

    Fisher, B. D.; Brown, P. W.; Plumer, J. A.

    1985-01-01

    The lightning strike condition data gathered in the 1980-1984 period are presented, together with the lightning attachment point analysis for the NASA F-106B research aircraft are presented. The analysis of the experienced 637 direct lightning strikes shows that the highest strike rates (2.1 strikes/min and 13 strikes/penetration) occurred at altitudes between 38,000 and 40,000 ft. The regions of highest risk for an aircraft to experience a direct lightning strike were the areas of thunderstorms where the ambient temperature was colder than -40 C and where the relative turbulence and precipitation intensities were characterized as negligible to light. The presence and location of lightning, therefore, did not necessarily indicate the presence and location of hazardous precipitation and turbulence. The total onboard data show that the lightning attachment patterns on this aircraft fall into four general categories, although the 1984 data suggest that the entire surface of the F-106B may be susceptible to lightning attachment.

  19. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  20. IEE wiring regulations explained and illustrated

    CERN Document Server

    Scaddan, Brian

    2013-01-01

    The IEE Wiring Regulations Explained and Illustrated, Second Edition discusses the recommendations of the IEE Regulations for the Electrical Equipment of Buildings for the safe selection or erection of wiring installations. The book emphasizes earthing, bonding, protection, and circuit design of electrical wirings. The text reviews the fundamental requirements for safety, earthing systems, the earth fault loop impedance, and supplementary bonding. The book also describes the different types of protection, such as protection against mechanical damage, overcurrent, under voltage (which prevents

  1. Minimisation of the wire position uncertainties of the new CERN vacuum wire scanner

    CERN Document Server

    AUTHOR|(CDS)2069346; Barjau Condomines, A

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new fast wire scanner is foreseen to measure small emittance beams throughout the LHC injector chain, which demands a wire travelling speed up to 20 ms-1 and position measurement accuracy of the order of a few microns. The vibrations of the mechanical parts of the system, and particularly the vibrations of the thin carbon wire, were identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations is a high priority for the design and operation of the new device. This document presents the work performed to understand the main causes of the wire vibrations observed in one of the existing wire scanner and the new proposed design.

  2. Using avian radar to examine relationships among avian activity, bird strikes, and meteorological factors

    Science.gov (United States)

    Coates, Peter S.; Casazza, Michael L.; Halstead, Brian J.; Fleskes, Joseph P.; Laughlin, James A.

    2011-01-01

    Radar systems designed to detect avian activity at airfields are useful in understanding factors that influence the risk of bird and aircraft collisions (bird strikes). We used an avian radar system to measure avian activity at Beale Air Force Base, California, USA, during 2008 and 2009. We conducted a 2-part analysis to examine relationships among avian activity, bird strikes, and meteorological and time-dependent factors. We found that avian activity around the airfield was greater at times when bird strikes occurred than on average using a permutation resampling technique. Second, we developed generalized linear mixed models of an avian activity index (AAI). Variation in AAI was first explained by seasons that were based on average migration dates of birds at the study area. We then modeled AAI by those seasons to further explain variation by meteorological factors and daily light levels within a 24-hour period. In general, avian activity increased with decreased temperature, wind, visibility, precipitation, and increased humidity and cloud cover. These effects differed by season. For example, during the spring bird migration period, most avian activity occurred before sunrise at twilight hours on clear days with low winds, whereas during fall migration, substantial activity occurred after sunrise, and birds generally were more active at lower temperatures. We report parameter estimates (i.e., constants and coefficients) averaged across models and a relatively simple calculation for safety officers and wildlife managers to predict AAI and the relative risk of bird strike based on time, date, and meteorological values. We validated model predictability and assessed model fit. These analyses will be useful for general inference of avian activity and risk assessment efforts. Further investigation and ongoing data collection will refine these inference models and improve our understanding of factors that influence avian activity, which is necessary to inform

  3. Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose:The Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL) provides a variety of research, design engineering and prototype fabrication services...

  4. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  5. The Role of Near-Fault Relief in Creating and Maintaining Strike-Slip Landscape Features

    Science.gov (United States)

    Harbert, S.; Duvall, A. R.; Tucker, G. E.

    2016-12-01

    Geomorphic landforms, such as shutter ridges, offset river terraces, and deflected stream channels, are often used to assess the activity and slip rates of strike-slip faults. However, in some systems, such as parts of the Marlborough Fault System (South Island, NZ), an active strike-slip fault does not leave a strong landscape signature. Here we explore the factors that dampen or enhance the landscape signature of strike-slip faulting using the Channel-Hillslope Integrated Landscape Development model (CHILD). We focus on variables affecting the length of channel offsets, which enhance the signature of strike-slip motion, and the frequency of stream captures, which eliminate offsets and reduce this signature. We model a strike-slip fault that passes through a mountain ridge, offsetting streams that drain across this fault. We use this setup to test the response of channel offset length and capture frequency to fault characteristics, such as slip rate and ratio of lateral to vertical motion, and to landscape characteristics, such as relief contrasts controlled by erodibility. Our experiments show that relief downhill of the fault, whether generated by differential uplift across the fault or by an erodibility contrast, has the strongest effect on offset length and capture frequency. This relief creates shutter ridges, which block and divert streams while being advected along a fault. Shutter ridges and the streams they divert have long been recognized as markers of strike-slip motion. Our results show specifically that the height of shutter ridges is most responsible for the degree to which they create long channel offsets by preventing stream captures. We compare these results to landscape metrics in the Marlborough Fault System, where shutter ridges are common and often lithologically controlled. We compare shutter ridge length and height to channel offset length in order to assess the influence of relief on offset channel features in a real landscape. Based on our

  6. FE modeling of Cu wire bond process and reliability

    NARCIS (Netherlands)

    Yuan, C.A.; Weltevreden, E.R.; Akker, P. van den; Kregting, R.; Vreugd, J. de; Zhang, G.Q.

    2011-01-01

    Copper based wire bonding technology is widely accepted by electronic packaging industry due to the world-wide cost reduction actions (compared to gold wire bond). However, the mechanical characterization of copper wire differs from the gold wire; hence the new wire bond process setting and new bond

  7. 47 CFR 76.804 - Disposition of home run wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of home run wiring. 76.804 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.804 Disposition of home run wiring. (a) Building-by-building disposition of home run wiring. (1) Where an MVPD owns the home run wiring in an MDU...

  8. [The Teachers' Right to Strike Versus the Students' Right to an Education.

    Science.gov (United States)

    Powell, Edward M.

    The speaker establishes himself in opposition to teacher strikes, outlines the scope of teacher strikes, discusses arguments for and against the right of teachers to strike, presents the kinds of strikes that are possible, outlines what a board and the administration can do to head off a strike, and presents the American Association of School…

  9. Intra-wire resistance and AC loss in multi-filamentary MgB2 wires

    NARCIS (Netherlands)

    Zhou, Chao; Offringa, Wietse; Bergen, Anne-Henriette; Wessel, Wilhelm A.J.; Krooshoop, Hendrikus J.G.; Dhalle, Marc M.J.; Sumption, M.D.; Collings, E.W.; Rindfleisch, M.; Tomsic, M.; ten Kate, Herman H.J.; Nijhuis, Arend

    2013-01-01

    Intra-wire resistance and AC loss of various multi-filamentary MgB2 wires with filaments surrounded by Nb barriers have been measured and analyzed. The intra-wire resistance is measured with a direct four-probe voltage–current method at various temperatures. The AC loss is acquired by both vibrating

  10. THERMO-MECHANICALLY PROCESSED ROLLED WIRE FOR HIGH-STRENGTH ON-BOARD WIRE

    Directory of Open Access Journals (Sweden)

    V. A. Lutsenko

    2011-01-01

    Full Text Available It is shown that at twisting of wire of diameter 1,83 mm, produced by direct wire drawing of thermomechanically processed rolled wire of diameter 5,5 mm of steel 90, metal stratification is completely eliminated at decrease of carbon, manganese and an additional alloying of chrome.

  11. Study of Flow Deformation around Wind-Vane Mounted Three-Dimensional Hot-Wire Probes

    DEFF Research Database (Denmark)

    Rømer Rasmussen, K.; Larsen, Søren Ejling; Jørgensen, F. E.

    1981-01-01

    Open wind tunnel tests on several different sensor systems consisting of triaxial hot-wire probes mounted on wind vanes (DISA and Riso vanes) have shown that flow deformation around the hot-wire sensor introduces errors in the measured velocity components. Though changes in the horizontal...... components proved to be negligible, flow deformation resulted in an overestimation of the vertical component from 1.1 to 1.5, depending on the direction of the vertical component. Turbulence and mean value data were adjusted by use of a linear correction derived from the wind tunnel tests. Wind vane...... construction must strike a compromise between minor flow disturbance and sufficient probe support. The final version of the DISA vane resulted in an acceptable vertical correction of about 10%....

  12. Isolated Sensorineural Hearing Loss as a Sequela after Lightning Strike

    Directory of Open Access Journals (Sweden)

    Mahfuz Turan

    2015-01-01

    Full Text Available In most of the surviving patients after a lightning strike, audiovestibular abnormalities have been reported. The most frequently reported type of abnormalities is a tympanic membrane perforation with hearing loss and external ear canal burn. However a sensor neural hearing loss and mixed type hearing loss can also occur, but these occur rarely. A nineteen-year-old female patient had, after a lightning strike, serious burns on the left ear, behind the ear, and on the chest and neck. She also had in her left ear 108 dB hearing loss with irregular central perforation and in her right ear 52 dB sensorineural hearing loss. There was no hearing loss before the strike. A hearing aid was recommended for the right ear and good care and follow-up were recommended for the left ear. A lightning strike can cause serious audiological damage. Therefore, it is necessary to make a careful audiovestibular evaluation of the patients. Although there exist rarely healed cases from sensorineural hearing loss after lightning strike in literature, in our case hearing loss occurred bilaterally and then it healed unilaterally. This condition is quite rare in literature.

  13. Long-Wearing Wire Guide For Welding Torch

    Science.gov (United States)

    Gutow, David A.; Burley, Richard K.; Gilbert, Jeffrey L.; Fogel, Irving

    1992-01-01

    Insert for wire-guide tube on tungsten/inert-gas welding apparatus extends life of guide tube and increases accuracy of weld. Hardened insert resists wear by sliding tungsten wire. Chamfer guides wire into insert.

  14. 29 CFR 1919.79 - Wire rope.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Wire rope. 1919.79 Section 1919.79 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... recommended by the equipment or the wire rope manufacturer due to actual working condition requirements. In...

  15. Automatic inspection of railway overhead wires

    NARCIS (Netherlands)

    Smorenburg, C.; Valkenburg, A.L.G. van

    1988-01-01

    For the Netherlands railway company a system for inspection of the degree of wear of the contact wires is being developed. With an active sensor the reflective under-surface of the overhead wire is illuminated with a laserbeam and reflected radiation is detected by fast CCD detectors. With the

  16. Wire compensation: Performance, SPS MDs, pulsed system

    CERN Document Server

    Dorda, U

    2008-01-01

    A wire compensation (BBLR) scheme has been proposed in order to improve the long range beam-beam performance of the nominal LHC and its phase 1 and phase 2 upgrades[1]. In this paper we present experimental experience of the CERN SPS wires (BBLR) and report on progress with the RF BBLR.

  17. WIRED magazine announces rave awards nominees

    CERN Multimedia

    2002-01-01

    WIRED Magazine has anounced the nominees for its fourth annual WIRED Rave Awards, celebrating innovation and the individuals transforming commerce and culture. Jeffrey Hangst of the University of Aarhus has been nominated in the science category, for his work on the ATHENA Experiment, CERN (1/2 page).

  18. Kirschner Wire Breakage during Removal Requiring Retrieval

    Directory of Open Access Journals (Sweden)

    Kai Yuen Wong

    2016-01-01

    Full Text Available Kirschner wires (K-wires are widely used for fixation of fractures and dislocations in the hand as they are readily available, reliable, and cost-effective. Complication rates of up to 18% have been reported. However, K-wire breakage during removal is rare. We present one such case illustrating a simple technique for retrieval. A 35-year-old male presented with a distal phalanx fracture of his right middle finger. This open fracture was treated with K-wire fixation. Postoperatively, he developed a pin site infection with associated finger swelling. The K-wire broke during removal with the proximal piece completely retained in his middle phalanx. To minimise risk of osteomyelitis, the K-wire was removed with a novel surgical technique. He had full return of hand function. Intraoperative K-wire breakage has a reported rate of 0.1%. In our case, there was no obvious cause of breakage and the patient denied postoperative trauma. On the other hand, pin site infections are much more common with reported rates of up to 7% in the hand or wrist. K-wire fixation is a simple method for bony stabilisation but can be a demanding procedure with complications often overlooked. It is important to be aware of the potential sequelae.

  19. Hot-wire anemometer for spirography.

    Science.gov (United States)

    Plakk, P; Liik, P; Kingisepp, P H

    1998-01-01

    The use of a constant temperature hot-wire anemometer flow sensor for spirography is reported. The construction, operating principles and calibration procedure of the apparatus are described, and temperature compensation method is discussed. Frequency response is studied. It is shown that this hot-wire flow transducer satisfies common demands with respect to accuracy, response time and temperature variations.

  20. Predicting timing of foot strike during running, independent of striking technique, using principal component analysis of joint angles.

    Science.gov (United States)

    Osis, Sean T; Hettinga, Blayne A; Leitch, Jessica; Ferber, Reed

    2014-08-22

    As 3-dimensional (3D) motion-capture for clinical gait analysis continues to evolve, new methods must be developed to improve the detection of gait cycle events based on kinematic data. Recently, the application of principal component analysis (PCA) to gait data has shown promise in detecting important biomechanical features. Therefore, the purpose of this study was to define a new foot strike detection method for a continuum of striking techniques, by applying PCA to joint angle waveforms. In accordance with Newtonian mechanics, it was hypothesized that transient features in the sagittal-plane accelerations of the lower extremity would be linked with the impulsive application of force to the foot at foot strike. Kinematic and kinetic data from treadmill running were selected for 154 subjects, from a database of gait biomechanics. Ankle, knee and hip sagittal plane angular acceleration kinematic curves were chained together to form a row input to a PCA matrix. A linear polynomial was calculated based on PCA scores, and a 10-fold cross-validation was performed to evaluate prediction accuracy against gold-standard foot strike as determined by a 10 N rise in the vertical ground reaction force. Results show 89-94% of all predicted foot strikes were within 4 frames (20 ms) of the gold standard with the largest error being 28 ms. It is concluded that this new foot strike detection is an improvement on existing methods and can be applied regardless of whether the runner exhibits a rearfoot, midfoot, or forefoot strike pattern. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Guide Wire Entrapment during Central Venous Catheterization

    Directory of Open Access Journals (Sweden)

    Kyung Woo Kim

    2014-05-01

    Full Text Available We experienced a case of venous vessel wall entrapment between the introducer needle and the guide wire during an attempt to perform right internal jugular vein (IJV catheterization. The guide wire was introduced with no resistance but could not be withdrawn. We performed ultrasonography and C-arm fluoroscopy to confirm the entrapment location. We assumed the introducer needle penetrated the posterior vessel wall during the puncture and that only the guide wire entered the vein; an attempt to retract the wire pinched the vein wall between the needle tip and the guide wire. Careful examination with various diagnostic tools to determine the exact cause of entrapment is crucial for reducing catastrophic complications and achieving better outcomes during catheterization procedures.

  2. VARIATION OF STRIKE INCENTIVES WITH DAMAGE PREFERENCES; FINAL

    International Nuclear Information System (INIS)

    G. CANAVAN

    2001-01-01

    For START III level forces, strike allocations and magnitudes vary little with L, but first strike costs vary directly with L, which means that for K reflecting a preference for the survival of high value targets over their destruction and a preference for high value over military targets, the costs of action are far greater than those of inaction for a wide range of values of damage preference L. Thus, if both sides have much greater preferences for the survival of their high value targets than for military targets or destruction, they do not see a net incentive to strike, and crises are terminated by inaction. Recent decades suggest strong preferences for the survival of high value and that this has contributed to the lack of direct conflict during that period

  3. Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires

    Directory of Open Access Journals (Sweden)

    Allahyar Geramy

    2017-12-01

    Full Text Available Objectives: The friction between the brackets and orthodontic wire during sliding mechanics inflicts difficulties such as decreasing the applied force and tooth movement and also the loss of anchorage. Therefore, many studies have focused on the factors that affect the friction. The purpose of this study was to assess the effect of 0.05% sodium fluoride mouthwash on the friction between orthodontic brackets and wire.Materials and Methods: Four types of orthodontic wires including rectangular standard stainless steel (SS, titanium molybdenum alloy (TMA, nickel-titanium (NiTi and copper-nickel-titanium (Cu-NiTi were selected. In each group, half of the samples were immersed in 0.05% sodium fluoride mouthwash and the others were immersed in artificial saliva for 10 hours. An elastomeric ligature was used for ligating the wires to brackets. The frictional test was performed in a universal testing machine at the speed of 10 mm/minute. Two-way ANOVA was used for statistical analysis of the friction rate.Results: The friction rate was significantly higher after immersion in 0.05% sodium fluoride mouthwash in comparison with artificial saliva (P=0.00. Cu-NiTi wire showed the highest friction value followed by TMA, NiTi and SS wires.  Conclusions: According to the results of the current study, 0.05% sodium fluoride mouthwash increased the frictional characteristics of all the evaluated orthodontic wires.

  4. Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires.

    Science.gov (United States)

    Geramy, Allahyar; Hooshmand, Tabassom; Etezadi, Tahura

    2017-09-01

    The friction between the brackets and orthodontic wire during sliding mechanics inflicts difficulties such as decreasing the applied force and tooth movement and also the loss of anchorage. Therefore, many studies have focused on the factors that affect the friction. The purpose of this study was to assess the effect of 0.05% sodium fluoride mouthwash on the friction between orthodontic brackets and wire. Four types of orthodontic wires including rectangular standard stainless steel (SS), titanium molybdenum alloy (TMA), nickel-titanium (NiTi) and copper-nickel-titanium (Cu-NiTi) were selected. In each group, half of the samples were immersed in 0.05% sodium fluoride mouthwash and the others were immersed in artificial saliva for 10 hours. An elastomeric ligature was used for ligating the wires to brackets. The frictional test was performed in a universal testing machine at the speed of 10 mm/minute. Two-way ANOVA was used for statistical analysis of the friction rate. The friction rate was significantly higher after immersion in 0.05% sodium fluoride mouthwash in comparison with artificial saliva (P=0.00). Cu-NiTi wire showed the highest friction value followed by TMA, NiTi and SS wires. According to the results of the current study, 0.05% sodium fluoride mouthwash increased the frictional characteristics of all the evaluated orthodontic wires.

  5. Comparison of blade-strike modeling results with empirical data

    Energy Technology Data Exchange (ETDEWEB)

    Ploskey, Gene R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Carlson, Thomas J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2004-03-01

    This study is the initial stage of further investigation into the dynamics of injury to fish during passage through a turbine runner. As part of the study, Pacific Northwest National Laboratory (PNNL) estimated the probability of blade strike, and associated injury, as a function of fish length and turbine operating geometry at two adjacent turbines in Powerhouse 1 of Bonneville Dam. Units 5 and 6 had identical intakes, stay vanes, wicket gates, and draft tubes, but Unit 6 had a new runner and curved discharge ring to minimize gaps between the runner hub and blades and between the blade tips and discharge ring. We used a mathematical model to predict blade strike associated with two Kaplan turbines and compared results with empirical data from biological tests conducted in 1999 and 2000. Blade-strike models take into consideration the geometry of the turbine blades and discharges as well as fish length, orientation, and distribution along the runner. The first phase of this study included a sensitivity analysis to consider the effects of difference in geometry and operations between families of turbines on the strike probability response surface. The analysis revealed that the orientation of fish relative to the leading edge of a runner blade and the location that fish pass along the blade between the hub and blade tip are critical uncertainties in blade-strike models. Over a range of discharges, the average prediction of injury from blade strike was two to five times higher than average empirical estimates of visible injury from shear and mechanical devices. Empirical estimates of mortality may be better metrics for comparison to predicted injury rates than other injury measures for fish passing at mid-blade and blade-tip locations.

  6. Single wire drift chamber design

    Energy Technology Data Exchange (ETDEWEB)

    Krider, J.

    1987-03-30

    This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 ..mu..m rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles.

  7. [Force-feeding of hunger-striking prisoners].

    Science.gov (United States)

    Glick, Shimon

    2014-09-01

    In contrast to the position of the World Medical Association and the Ethics Council of the Israel Medical Association, the author argues for forced-feeding of hunger-striking prisoners when their condition reaches a stage of danger of death or permanent injury. This position is based on the priority of human life over autonomy, and of a communitarian ethic. This position is supported by a District Court decision ordering the feeding of a hunger-striking prisoner, by a Supreme Court decision imposing surgery on a non-consenting prisoner, and in line with Israel's Patient's Right Law.

  8. Sound Quality and Striking Position of a Conga Drum

    Directory of Open Access Journals (Sweden)

    Dylan Harvey

    2014-12-01

    Full Text Available The relationship between the location at which a drum membrane was struck and the quality of sound produced was investigated by striking the drum at several distances between the center and the rim. Through analyzing the harmonics of the wave produced from the impact, it was shown that as the striking location changes, the relative amplitudes of different modes of vibration also changes. It was found that sound of a higher pitch is produced at the rim of the drum than anywhere else on the drum head due to higher modes of vibration becoming dominant.

  9. MORE THAN A LABOR DISPUTE: THE PATCO STRIKE OF 1981

    Directory of Open Access Journals (Sweden)

    Paul L. Butterworth

    2005-01-01

    Full Text Available On August 3, 1981, 13,000 air traffic controllers walked off the job. Under US law, the strike was illegal. President Ronald Reagan ordered the strikers as a group to return to work; when they did not, he ordered individual strikers to return, and again they refused. Two days later the president fired the strikers. Reagan's action transformed relations between organized labor and American management, and created the worst turbulence to hit the American airways in recent history. “More Than a Labor Dispute” examines the work stoppage and aftermath through the eyes of two controllers and a pilot, all of whom worked during the strike.

  10. Remarkable rates of lightning strike mortality in Malawi.

    Science.gov (United States)

    Mulder, Monique Borgerhoff; Msalu, Lameck; Caro, Tim; Salerno, Jonathan

    2012-01-01

    Livingstone's second mission site on the shore of Lake Malawi suffers very high rates of consequential lightning strikes. Comprehensive interviewing of victims and their relatives in seven Traditional Authorities in Nkhata Bay District, Malawi revealed that the annual rate of consequential strikes was 419/million, more than six times higher than that in other developing countries; the rate of deaths from lightning was 84/million/year, 5.4 times greater than the highest ever recorded. These remarkable figures reveal that lightning constitutes a significant stochastic source of mortality with potential life history consequences, but it should not deflect attention away from the more prominent causes of mortality in this rural area.

  11. A new method for cerclage wire fixation to maximal pre-tension with minimal elongation to failure.

    Science.gov (United States)

    Meyer, Dominik C; Ramseier, Leo E; Lajtai, Georg; Nötzli, Hubert

    2003-12-01

    To develop and test a new cerclage wire tightening technique, yielding reproducibly maximal pre-tension, load to failure and minimal elongation to failure of the wire junction. Laboratory bench study. Cerclage wire fixation is difficult to perform by hand with reproducible quality and tightening tension, which are required for optimal performance. With the new technique, 1, 1.25 and 1.5 mm steel wires were passed through a 9 x 18 mm steel tube, grasped using a modified ASIF wire-tightener and tightened by twisting until spontaneous failure of the wires in the tube. These fixations were compared to wires pre-tightened by hand to controlled high or low pre-tension using the simple twist, the knot twist and twist secured against untwisting, loaded to failure on a testing machine. The tests assessed pre-tension, ultimate failure load and elongation to failure. Wire twists performed with the new technique were always perfectly symmetrical and may be tightened to maximal pre-tension without weakening of the wire. The twist secured against untwisting combined high stiffness with high failure load. The knot twist elongates to an unacceptable degree, unlike the secured twist. The simple twist untwists under little tension. The new technique allows to obtain maximal pre-tension and thus minimal elongation to failure of simple wire twists, without having to worry about breaking the wire at the base of the twist due to over-tightening. Cerclage wire fixation is an effective and cheap method to perform osteosynthesis. For adequate performance, maximal pre-tension, symmetrical twisting and high load to failure are necessary. The here presented technique combines all of these pre-requisites in a simple fashion.

  12. Mass accretion and nested array dynamics from Ni-Clad Ti-Al wire array Z pinches

    International Nuclear Information System (INIS)

    Jones, Brent Manley; Jennings, Christopher A.; Coverdale, Christine Anne; Cuneo, Michael Edward; Maron, Yitzhak; LePell, Paul David; Deeney, Christopher

    2010-01-01

    Analysis of 50 mm diameter wire arrays at the Z Accelerator has shown experimentally the accretion of mass in a stagnating z pinch and provided insight into details of the radiating plasma species and plasma conditions. This analysis focused on nested wire arrays with a 2:1 (outeninner) mass, radius, and wire number ratio where Al wires were fielded on the outer array and Ni-clad Ti wires were fielded on the inner array.In this presentation, we will present analysis of data from other mixed Al/Ni-clad Ti configurations to further evaluate nested wire array dynamics and mass accretion. These additional configurations include the opposite configuration to that described above (Ni-clad Ti wires on the outer array, with Al wires on the inner array) as well as higher wire number Al configurations fielded to vary the interaction of the two arrays. These same variations were also assessed for a smaller diameter nested array configuration (40 mm). Variations in the emitted radiation and plasma conditions will be presented, along with a discussion of what the results indicate about the nested array dynamics. Additional evidence for mass accretion will also be presented.

  13. Comparison between C1-2 Fixation with and without Supplemental Posterior Wiring.

    Science.gov (United States)

    Tran, Mai; Wadhwa, Rishi; Ziewacz, John; Mummaneni, Praveen; Chou, Dean

    2014-04-01

    Study Design Retrospective analysis. Clinical Question Is there a difference between the screw-rod construct (SRC) procedure without wiring and the SRC procedure with wiring with respect to fusion, implant failure, reoperation, donor-site morbidity, and complication rates? Patients and Methods We performed a retrospective analysis of 26 patients who underwent C1-2 fixation between 2004 and 2012 (SRC with wiring and structural bone graft, 13 patients; SRC with autograft but without wiring, 13 patients). Fusion was assessed using dynamic X-rays in all patients and computed tomographic scans in selected cases. Pseudoarthrosis was confirmed during reoperation. Results The mean follow-up time was 2 years and 5 months for the SRC without wiring group and 2 years and 1 month for the SRC with wiring group. Patients with less than 1-year follow-up time were excluded. The fusion rate, implant failure rate, and reoperation rates for the SRC without wiring group were 92, 8, and 8%, respectively. The fusion, implant failure, and reoperation rates for the SRC with wiring group were 100, 0, and 0%, respectively. There were no donor-site morbidities or complications in either group (both 0%). There were no differences in parameters we examined between the two groups (p > 0.05 for each rate, Fisher exact test). Conclusions The results suggest that supplementing the SRC procedure with wiring may increase fusion rate, but this difference is not statistically significant. Although the sample size was small, there was not a significant discrepancy in outcomes between the two groups at an average follow-up of 2 years. [Table: see text].

  14. Bioactivity and osteointegration of hydroxyapatite-coated stainless steel and titanium wires used for intramedullary osteosynthesis.

    Science.gov (United States)

    Popkov, Arnold V; Gorbach, Elena N; Kononovich, Natalia A; Popkov, Dmitry A; Tverdokhlebov, Sergey I; Shesterikov, Evgeniy V

    2017-08-01

    A lot of research was conducted on the use of various biomaterials in orthopedic surgery. Our study investigated the effects of nanostructured calcium-phosphate coating on metallic implants introduced into the bone marrow canal. Stainless steel or titanium 2-mm wires (groups 1 and 2, respectively), and hydroxyapatite-coated stainless steel or titanium wires of the same diameter (groups 3 and 4, respectively) were introduced into the tibial bone marrow canal of 20 dogs (each group = 5 dogs). Hydroxyapatite coating was deposited on the wires with the method of microarc oxidation. Light microscopy to study histological diaphyseal transverse sections, scanning electron microscopy to study the bone marrow area around the implant and an X-ray electron probe analyzer to study the content of calcium and phosphorus were used to investigate bioactivity and osteointegration after a four weeks period. Osteointegration was also assessed by measuring wires' pull-off strength with a sensor dynamometer. Bone formation was observed round the wires in the bone marrow canal in all the groups. Its intensity depended upon the features of wire surfaces and implant materials. Maximum percentage volume of trabecular bone was present in the bone marrow canals of group 4 dogs that corresponded to a mean of 27.1 ± 0.14%, while it was only 6.7% in group 1. The coating in groups 3 and 4 provided better bioactivity and osteointegration. Hydroxyapatite-coated titanium wires showed the highest degree of bone formation around them and greater pull-off strength. Nanostructured hydroxyapatite coating of metallic wires induces an expressed bone formation and provides osteointegration. Hydroxyapatite-coated wires could be used along with external fixation for bone repair enhancement in diaphyseal fractures, management of osteogenesis imperfecta and correction of bone deformities in phosphate diabetes.

  15. Minimum quench energy measurement for superconducting wires

    International Nuclear Information System (INIS)

    Seo, K.; Morita, M.; Nakamura, S.; Yamada, T.; Jizo, Y.

    1996-01-01

    The authors have developed a new method of measuring minimum quench energy (MQE) of superconducting wire. There have been conventional methods using heating wires, whose diameters are ∼0.1mm and are glued by epoxy resin. When they induce a pulse heat to superconducting wires, a duration of the pulse must be several hundreds micro seconds to demonstrate actual disturbances (for instance wire motion) in a superconducting magnet. In spite of this fact, thermal diffusion time constants of the conventional heaters are larger than the duration of the actual disturbance, because of these electrical insulator of the heating wire and the epoxy bind. Therefore, this kind of heater is not able to demonstrate the actual disturbance. To solve this problem, they have proposed a new constitution of a heater. In the method, heat generation is introduced in high resistive layer on a surface of a superconducting wire. The high resistive layer is consist of carbon paste. The thickness of the carbon paste layer is ∼20microm, thus a time constant of this heater is expected to be small enough to demonstrate the actual disturbance. Adopting the new method to the MQE measurement, they successfully evaluate MQE of superconducting wires with high precision. Several results are introduced in this paper

  16. Wire pad chamber for LHCb muon system

    CERN Document Server

    Botchine, B; Lazarev, V A; Sagidova, N; Vorobev, A P; Vorobyov, A; Vorobyov, Alexei

    2000-01-01

    2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.

  17. EDITORIAL Plagiarism - time to strike at the epidemic

    African Journals Online (AJOL)

    admin

    Plagiarism - time to strike at the epidemic. Lukman Yusuf1, Abraham Aseffa2. We live in a globalized world where information is instantly shared across continents. The number of biomedical journals available for reference is quite enormous and there is a sudden huge surge of free open access journals in the last few years ...

  18. The Eastern Pacific Tropical Cyclone Strike Probability Program (EPSTRKP).

    Science.gov (United States)

    1980-08-01

    of nine preselected points of interest. Although subject to change the points currently listed within the program are: Acapulco, Mazatlan, Puerto ... Vallarta , La Paz, San Diego, Hilo, Honolulu, Johnston Island and Midway Island. The strike probabilities, computed upon receipt of each 6-hourly warning

  19. Effects of Union Organization on Strike Incidence in EU Companies

    NARCIS (Netherlands)

    Jansen, Giedo

    2014-01-01

    The author reinvestigates the relationship between the organizational power of trade unions and strikes based on data from the European Company Survey 2009 (ECS-2009) and the Institutional Characteristics of Trade Unions, Wage Setting, State Intervention and Social Pacts (ICTWSS) database, which

  20. Monte Carlo Simulation to Estimate Likelihood of Direct Lightning Strikes

    Science.gov (United States)

    Mata, Carlos; Medelius, Pedro

    2008-01-01

    A software tool has been designed to quantify the lightning exposure at launch sites of the stack at the pads under different configurations. In order to predict lightning strikes to generic structures, this model uses leaders whose origins (in the x-y plane) are obtained from a 2D random, normal distribution.

  1. Torts Liability for Strike Action and Third Party Rights.

    Science.gov (United States)

    Raday, Frances

    1979-01-01

    Studies the nature of the torts liability incurred in strikes and the extent of existing immunities bestowed on strikers and their organizers, and explores the principles that should govern liability and immunity. Available from Israel Law Review Association, c/o Faculty of Law, Hebrew University of Jerusalem, Mount Scopus, P.O.B. 24100, Jerusalem…

  2. Nurses need the right to strike to protect patients.

    Science.gov (United States)

    Harrison, Malcolm

    2012-04-25

    Four of your readers panellists were asked if the RCN should be affiliated to the Trades Union Congress (reflections April 4). One of them said the RCN needs to modernise and join the wider trade union movement, but 'should keep the "no strike" policy that has always served it so well'.

  3. Analysis of the effects of frequent strikes on academic performance ...

    African Journals Online (AJOL)

    The history of Academic Staff Union of Universities (ASUU)'s strike can be traced back to 1978, the period of the beginning of the decline in the oil boom, when the country faced the consequences of the failure by its rulers to use the oil wealth to generate production and a social welfare system. Military dictatorship had ...

  4. On Striking for a Bargain between Two Completely Informed Agents

    NARCIS (Netherlands)

    Houba, H.E.D.; Wen, Q.

    2007-01-01

    This paper provides a thorough equilibrium analysis of a wage contract negotiation model where the union must choose between strike and holdout between offers and counter-offers. When the union and the firm have different discount factors, delay in reaching an agreement may Pareto dominate many

  5. Assemblage of strike-slip faults and tectonic extension and ...

    Indian Academy of Sciences (India)

    12

    and its effect on the productivity of the tight reservoirs. The study will not only guide. 95 the oil-gas ..... 5 Effect of tectonic extension and compression on coal reservoir productivity. 288. 5.1 Strike-slip compression and ..... staff of all the authors that cooperated in performing the analyses. We are also. 425 grateful to the ...

  6. Assemblage of strike-slip faults and tectonic extension and ...

    Indian Academy of Sciences (India)

    12

    Assemblage of strike-slip faults and tectonic. 1 extension and compression analysis: A case. 2 study of a Lower Permian commercial coal. 3 reservoir in China. 4. 5. Shuai Yina,*, Dawei Lvb, Zhonghu Wu c .... high-quality reservoirs, and tectonic action is a leading factor for oil and gas. 70 enrichment. Therefore, it is of great ...

  7. BIRD/WILDLIFE STRIKE CONTROL FOR SAFER AIR ...

    African Journals Online (AJOL)

    Osondu

    2012-06-05

    Jun 5, 2012 ... These include staff training and retraining, developing good data bank based on .... wildlife is very important in bird control. Successful habitat ... Designated staff patrols the airside areas using chemical repellants, propane cannons, distress call. Birds/Wildlife Strikes Control for Safer Air .................Usman et ...

  8. LAW AND ETHICS OF STRIKES IN THE NIGERIAN HEALTH SYSTEM

    African Journals Online (AJOL)

    2014-10-06

    Oct 6, 2014 ... MDCN Code of ethics intends to give right for cessation of work by workers in the health sector of the economy. Thus under the Common Law, a strike, especially in the essential services is a breach of the contract of employment. The Trade. Union (amendment) Act (Federal Republic of. Nigeria, 2005) ...

  9. Growth control of kalanchoe cultivars Rako and Gold Strike by ...

    African Journals Online (AJOL)

    This study was conducted to test the potential of paclobutrazol and uniconazole used at the propagation stage as a plant growth retardant (PGR) of kalanchoe cultivars Rako and Gold Strike. Three node terminal cuttings were soaked in 500 mL of 0.05, 0.25, or 0.50 mg·L-1 paclobutrazol or uniconazole solution for 2 h.

  10. Striking Inside Angola with 32 Battalion | Scheepers | Scientia ...

    African Journals Online (AJOL)

    Scientia Militaria: South African Journal of Military Studies. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 42, No 1 (2014) >. Log in or Register to get access to full text downloads. Username, Password, Remember me, or Register. Striking Inside Angola with 32 ...

  11. Force, reaction time, and precision of Kung Fu strikes.

    Science.gov (United States)

    Neto, Osmar Pinto; Bolander, Richard; Pacheco, Marcos Tadeu Tavares; Bir, Cynthia

    2009-08-01

    The goal was to compare values of force, precision, and reaction time of several martial arts punches and palm strikes performed by advanced and intermediate Kung Fu practitioners, both men and women. 13 Kung Fu practitioners, 10 men and three women, participated. Only the men, three advanced and seven intermediate, were considered for comparisons between levels. Reaction time values were obtained using two high speed cameras that recorded each strike at 2500 Hz. Force of impact was measured by a load cell. For comparisons of groups, force data were normalized by participant's body mass and height. Precision of the strikes was determined by a high speed pressure sensor. The results show that palm strikes were stronger than punches. Women in the study presented, on average, lower values of reaction time and force but higher values of precision than men. Advanced participants presented higher forces than intermediate participants. Significant negative correlations between the values of force and precision and the values of force and reaction time were also found.

  12. Resonant tunneling of electrons in quantum wires

    International Nuclear Information System (INIS)

    Krive, I.V.; Shekhter, R.I.; Jonson, M.; Krive, I.V.

    2010-01-01

    We considered resonant electron tunneling in various nanostructures including single wall carbon nanotubes, molecular transistors and quantum wires formed in two-dimensional electron gas. The review starts with a textbook description of resonant tunneling of noninteracting electrons through a double-barrier structure. The effects of electron-electron interaction in sequential and resonant electron tunneling are studied by using Luttinger liquid model of electron transport in quantum wires. The experimental aspects of the problem (fabrication of quantum wires and transport measurements) are also considered. The influence of vibrational and electromechanical effects on resonant electron tunneling in molecular transistors is discussed.

  13. Problems associated with iridium-192 wire implants

    International Nuclear Information System (INIS)

    Arnott, S.J.; Law, J.; Ash, D.; Flynn, A.; Paine, C.H.; Durrant, K.R.; Barber, C.D.; Dixon-Brown, A.

    1985-01-01

    Three incidents are reported, from different radiotherapy centres, in which an implanted iridium-192 wire remained in the tissues of a patient after withdrawal of the plastic tubing in which it was contained. In each case the instrument used to cut the wire had probably formed a hook on the end of the wire which caused it to catch in the tissues. Detailed recommendations are made for avoiding such incidents in the future, the most important of which is that the patient should be effectively monitored after the supposed removal of all radioactive sources. (author)

  14. Investigation of wire motion in superconducting magnets

    International Nuclear Information System (INIS)

    Ogitsu, T.; Tsuchiya, K.; Devred, A.

    1990-09-01

    The large Lorentz forces occuring during the excitation of superconducting magnets can provoke sudden motions of wire, which eventually release enough energy to trigger a quench. These wire motions are accompanied by two electromagnetic effects: an induced emf along the moved wire, and a local change in flux caused by the minute dislocation of current. Both effects cause spikes in the coil voltage. Voltage data recorded during the excitation of a superconducting quadrupole magnet which early exhibit such events are here reported. Interpretations of the voltage spikes in terms of energy release are also presented, leading to insights on the spectrum of the disturbances which occur in real magnets. 15 refs

  15. [Evaluation of the corrosion resistance of orthodontic wires by electrochemical measures and scanning electron microscopy (SEM)].

    Science.gov (United States)

    Zoghbi, André El; Klein, Lorena; Frateur, Isabelle

    2013-12-01

    The objective of this paper is to study the corrosion resistance of orthodontic wires made of different alloys (stainless steel, chrome-cobalt, nickel-titanium and β-titanium) and for the same alloy from different vendors (GAC(®), RMO(®), 3M(®) and ORMCO(®)). Different electrochemical techniques (corrosion potential monitoring as a function of immersion time, current-potential curves, electrochemical impedance spectroscopy (EIS)) were used. The wires' resistance to corrosion was measured and compared with the surface condition, assessed by scanning electron microscopy (SEM). Using the recorded data, a rating system based on the corrosion resistance of orthodontic wires was developed. The comparison of these data with the results of SEM shows that the surface chemical composition plays a primary role in the electrochemical behavior of the orthodontic wires and, unlike surface defects, is a key parameter for the corrosion resistance of the alloy. © EDP Sciences, SFODF, 2013.

  16. Case Report: Mass Casualty Lightning Strike at Ranger Training Camp.

    Science.gov (United States)

    Thompson, Shannon N; Wilson, Zachary W; Cole, Christopher B; Kennedy, Andrew R; Aycock, Ryan D

    2017-05-01

    Although lightning strikes are a rare occurrence, their significance cannot be ignored given military operations in the field during all types of weather. With proper medical management, patients with lightning injuries can return to duty. Information for this case report comes from eyewitness account at the 6th Ranger Training Battalion and from review of physician documentation from the 96th Medical Group, Eglin Air Force Base, Florida. A lightning strike injured 44 Ranger School participants during a training exercise on August 12, 2015, at Camp Rudder, Florida. These patients were triaged in the field and transported to emergency department of Eglin Air Force Base. Of the 44 casualties, 20 were admitted. All were returned to duty the following day. One patient had cardiac arrest. This patient, along with two others, was admitted to the intensive care unit. Seventeen other patients were admitted for observation for rhabdomyolysis and/or cardiac arrhythmias. One patient was admitted with suspected acute kidney injury indicated by an elevated creatinine. All patients, including those admitted to the intensive care unit, were released on the day following the lightning strike without restrictions and were allowed to return to duty with increased medical monitoring. This case report highlights the need for proper triage and recognition of lightning strike injury, coordination of care between field operations and emergency department personnel, and close follow-up for patients presenting with lightning injury. Symptoms, physical exam, and laboratory findings from rigorous training can be difficult to distinguish from those resulting from lightning injury. Secondary injuries resulting from blunt trauma from falls may have been prevented by the use of the lightning strike posture. Further analysis of procedures and standard operating protocols to mitigate risk during thunderstorms may be required to prevent lightning's effects on large groups of military personnel

  17. Management of patients during hunger strike and refeeding phase.

    Science.gov (United States)

    Eichelberger, M; Joray, M L; Perrig, M; Bodmer, M; Stanga, Z

    2014-01-01

    Hunger strikers resuming nutritional intake may develop a life-threatening refeeding syndrome (RFS). Consequently, hunger strikers represent a core challenge for the medical staff. The objective of the study was to test the effectiveness and safety of evidence-based recommendations for prevention and management of RFS during the refeeding phase. This was a retrospective, observational data analysis of 37 consecutive, unselected cases of prisoners on a hunger strike during a 5-y period. The sample consisted of 37 cases representing 33 individual patients. In seven cases (18.9%), the hunger strike was continued during the hospital stay, in 16 episodes (43.2%) cessation of the hunger strike occurred immediately after admission to the security ward, and in 14 episodes (37.9%) during hospital stay. In the refeed cases (n = 30), nutritional replenishment occurred orally, and in 25 (83.3%) micronutrients substitutions were made based on the recommendations. The gradual refeeding with fluid restriction occurred over 10 d. Uncomplicated dyselectrolytemia was documented in 12 cases (40%) within the refeeding phase. One case (3.3%) presented bilateral ankle edemas as a clinical manifestation of moderate RFS. Intensive medical treatment was not necessary and none of the patients died. Seven episodes of continued hunger strike were observed during the entire hospital stay without medical complications. Our data suggested that seriousness and rate of medical complications during the refeeding phase can be kept at a minimum in a hunger strike population. This study supported use of recommendations to optimize risk management and to improve treatment quality and patient safety in this vulnerable population. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Joint angle measurement: a comparative study of the reliability of goniometry and wire tracing for the hand.

    Science.gov (United States)

    Ellis, B; Bruton, A; Goddard, J R

    1997-11-01

    To compare the inter- and intra-rater reliability of goniometry and wire tracing in the assessment of finger joint angles: metacarpo-phalangeal (MCPJ), proximal (PIPJ) and distal interphalangeal joints (DIPJ). Twenty occupational therapists and 20 physiotherapists with a range of clinical experience were recruited from nine different centres. Using a masked goniometer and wire tracing they carried out repeated assessments of the MCPJ, PIPJ and DIPJ of a normal subject fixed in two different positions. The two assessment methods did not produce comparable angle measurements. Goniometry showed greater inter- and intra-rater reliability than wire tracing. Regardless of the assessment tool, the repeatability coefficient indicated that DIPJ measurement was less reliable than the other joints. Clinical and specialist experience did not affect reliability. Although both goniometry and wire tracing show limitations as reliable assessment tools, it is recommended that where possible goniometry should be used.

  19. Implications of Incessant Strike Actions on the Implementation of Technical Education Programme in Nigeria

    Science.gov (United States)

    Adavbiele, J. A.

    2015-01-01

    This paper was designed to x-ray the implications of incessant strike actions on the implementation of Technical education programme in Nigeria. The paper took an exploratory view on the concept of strike actions in Nigeria with particular references on notable strike actions that have occurred in Nigeria. The types of strike were explained and…

  20. 47 CFR 76.802 - Disposition of cable home wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of cable home wiring. 76.802... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... cable operator shall not remove the cable home wiring unless it gives the subscriber the opportunity to...

  1. Automatic reel controls filler wire in welding machines

    Science.gov (United States)

    Millett, A. V.

    1966-01-01

    Automatic reel on automatic welding equipment takes up slack in the reel-fed filler wire when welding operation is terminated. The reel maintains constant, adjustable tension on the wire during the welding operation and rewinds the wire from the wire feed unit when the welding is completed.

  2. 47 CFR 32.2321 - Customer premises wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Customer premises wiring. 32.2321 Section 32... Customer premises wiring. (a) This account shall include all amounts transferred from the former Account 232, Station Connections, inside wiring subclass. (b) Embedded Customer Premises Wiring is that...

  3. 30 CFR 77.701-3 - Grounding wires; capacity.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity. 77.701-3 Section 77... MINES Grounding § 77.701-3 Grounding wires; capacity. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames, casings, and other metallic enclosures, such grounding wires will be...

  4. Wire Bonder: Kulicke and Soffa Model 4526

    Data.gov (United States)

    Federal Laboratory Consortium — Description:CORAL Name: Wire BonderNeeds Description.Scientific Opportunities / Applications:Wedge bonderSemi-automatic and manual modesIndependent Z-axis control,...

  5. Beam Profiling through Wire Chambing Tracking

    CERN Document Server

    Nash, W

    2013-01-01

    This note describes the calibration of the Delay Wire Chambers (DWCs) used during test runs of CALICE’s Tungsten Digital Hadron Calorimeter (W-DHCAL) prototype in CERN’s SPS beam line (10 – 300 GeV).

  6. Copyright and Wire Broadcasting Under Belgian Law

    Science.gov (United States)

    Namurois, Albert

    1975-01-01

    A discussion of a case whereby substantial damages, if not criminal proceedings, will sanction, according to circumstances, both television organizations and those who in certain conditions distribute their programs by wire or communicate them to the public. (Author/HB)

  7. Josephson junction arrays and superconducting wire networks

    International Nuclear Information System (INIS)

    Lobb, C.J.

    1992-01-01

    Techniques used to fabricate integrated circuits make it possible to construct superconducting networks containing as many as 10 6 wires or Josephson junctions. Such networks undergo phase transitions from resistive high-temperature states to ordered low-resistance low-temperature states. The nature of the phase transition depends strongly on controllable parameters such as the strength of the superconductivity in each wire or junction and the external magnetic field. This paper will review the physics of these phase transitions, starting with the simplest zero-magnetic field case. This leads to a Kosterlitz-Thouless transition when the junctions or wires are weak, and a simple mean-field fransition when the junctions or wires are strong. Rich behavior, resulting from frustration, occurs in the presence of a magnetic field. (orig.)

  8. Highly stretchable wrinkled gold thin film wires.

    Science.gov (United States)

    Kim, Joshua; Park, Sun-Jun; Nguyen, Thao; Chu, Michael; Pegan, Jonathan D; Khine, Michelle

    2016-02-08

    With the growing prominence of wearable electronic technology, there is a need to improve the mechanical reliability of electronics for more demanding applications. Conductive wires represent a vital component present in all electronics. Unlike traditional planar and rigid electronics, these new wearable electrical components must conform to curvilinear surfaces, stretch with the body, and remain unobtrusive and low profile. In this paper, the piezoresistive response of shrink induced wrinkled gold thin films under strain demonstrates robust conductive performance in excess of 200% strain. Importantly, the wrinkled metallic thin films displayed negligible change in resistance of up to 100% strain. The wrinkled metallic wires exhibited consistent performance after repetitive strain. Importantly, these wrinkled thin films are inexpensive to fabricate and are compatible with roll to roll manufacturing processes. We propose that these wrinkled metal thin film wires are an attractive alternative to conventional wires for wearable applications.

  9. Tensosensitivity of the Hot-Wire Probe

    National Research Council Canada - National Science Library

    Pak, A

    2002-01-01

    ...., on the anemometer type. In a constant current anemometer, it is possible to measure and separate out the noise moving to the electric circuit of the anemometer, it is not the case with hot-wire anemometers of other types...

  10. Molecular wires, switches and memories

    Science.gov (United States)

    Chen, Jia

    Molecular electronics, an emerging field, makes it possible to build individual molecules capable of performing functions identical or analogous to present- day conductors, switches, or memories. These individual molecules, with a nano-meter scale characteristic length, can be designed and chemically synthesized with specific atoms, geometries and charge distribution. This thesis focuses on the design, and measurements of molecular wires, and related strategically engineered structures-molecular switches and memories. The experimental system relies on a thermodynamically driven self-assembling process to attach molecules onto substrate surfaces without intervention from outside. The following topics will be discussed: directed nanoscale manipulation of self-assembled molecules using scanning tunneling microscope; investigation on through-bond transport of nanoscale symmetric metal/conjugated self- assembled monolayers (SAM)/metal junctions, where non- Ohmic thermionic emission was observed to be the dominant process, with isocyanide-Pd contacts showing the lowest thermionic barrier of 0.22 eV; the first realization of robust and large reversible switching behavior in an electronic device that utilizes molecules containing redox centers as the active component, exhibiting negative differential resistance (NDR) and large on-off peak-to-valley ratio (PVR); observation of erasable storage of higher conductivity states in these redox- center containing molecular devices, and demonstration of a two-terminal electronically programmable and erasable molecular memory cell with long bit retention time.

  11. Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires.

    Science.gov (United States)

    Tada, Yoshifumi; Hayakawa, Tohru; Nakamura, Yoshiki

    2017-08-09

    Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 × 0.022 in² and 0.019 × 0.025 in² (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bending properties were evaluated in a modified three-point bending system for orthodontics. The static friction between the orthodontic wire and the bracket was also measured. The load-deflection curves were similar among Ni-Ti and PEEK wires, except for 16PEEK with slot-lid ligation. The bending force of 19-25PEEK wire was comparable with that of Ni-Ti wire. 19-25PEEK showed the highest load at the deflection of 1500 μm ( p 0.05). No significant difference was seen in static friction between all three PEEK wires and Ni-Ti wire ( p > 0.05). It is suggested that 19-25PEEK will be applicable for orthodontic treatment with the use of slot-lid ligation.

  12. Audio wiring guide how to wire the most popular audio and video connectors

    CERN Document Server

    Hechtman, John

    2012-01-01

    Whether you're a pro or an amateur, a musician or into multimedia, you can't afford to guess about audio wiring. The Audio Wiring Guide is a comprehensive, easy-to-use guide that explains exactly what you need to know. No matter the size of your wiring project or installation, this handy tool provides you with the essential information you need and the techniques to use it. Using The Audio Wiring Guide is like having an expert at your side. By following the clear, step-by-step directions, you can do professional-level work at a fraction of the cost.

  13. Note: Improved wire-wound heater.

    Science.gov (United States)

    Steinmann, Ricardo G; Vitoux, Hugo

    2015-01-01

    The authors have measured, at cryogenic temperature, the upper limit of the heat transfer in different configurations of a wire-wound heater. We found that the heat transferred has an upper limit of about 15 W/cm(2) and is dependent on the diameter of the wire. In this paper, we present three ways of increasing the heat transferred by this type of heater and its application in different continuous flow cryostats.

  14. Graphene wire medium: Homogenization and application

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Chigrin, Dmitry N.; Lavrinenko, Andrei

    2012-01-01

    In this contribution we analyze numerically the optical properties of the graphene wire medium, which unit cell consists of a stripe of graphene embedded into dielectric. We propose a simple method for retrieval of the isofrequency contour and effective permittivity tensor. As an example...... of the graphene wire medium application we demonstrate a reconfigurable hyperlens for the terahertz subwavelength imaging capable of resolving two sources with separation λ0/5 in the far-field....

  15. Novel use of the "buddy"wire.

    LENUS (Irish Health Repository)

    O'Hare, A

    2008-12-29

    Summary: During interventional procedures the tortuosity of the vasculature hampers catheter stability. The buddy wire may be used to aid and maintain vascular access.We describe a case of acute subarachnoid haemorrhage secondary to dissecting aneurysm of the vertebral artery.We discuss the value of the buddy wire during balloon occlusion of the vertebral artery not as it is typically used, but to actually prevent the balloon repeatedly entering the posterior inferior cerebellar artery during the procedure.

  16. A Magnetic Sensor with Amorphous Wire

    Directory of Open Access Journals (Sweden)

    Dongfeng He

    2014-06-01

    Full Text Available Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  17. COBRA-IV wire wrap data comparisons

    International Nuclear Information System (INIS)

    Donovan, T.E.; George, T.L.; Wheeler, C.L.

    1979-02-01

    Thermal hydraulic analyses of hexagonally packed wire-wrapped fuel assemblies are complicated by the induced crossflow between adjacent subchannels. The COBRA-IV computer code simultaneously solves the hydrodynamics and thermodynamics of fuel assemblies. The modifications and the results are presented which are predicted by the COBRA-IV calculation. Comparisons are made with data measured in five experimental models of a wire-wrapped fuel assembly

  18. Wiring System Diagnostic Techniques for Legacy Aircraft

    Science.gov (United States)

    2003-02-01

    Reunions des specialistes des techniques de estion du cycle de vie pour vehicules aeriens vieillissants ] To order the complete compilation report, use...Ageing Mechanisms and Control. Specialists’ Meeting on Life Management Techniques for Ageing Air Vehicles [Les mecanismes vieillissants et le controle...be identified. Additionally, wiring failures tend to be intermittent in nature and can take considerable time to isolate. Wire modifications and

  19. Subchannel Analysis of Wire Wrapped SCWR Assembly

    Directory of Open Access Journals (Sweden)

    Jianqiang Shan

    2014-01-01

    Full Text Available Application of wire wrap spacers in SCWR can reduce pressure drop and obtain better mixing capability. As a consequence, the required coolant pumping power is decreased and the coolant temperature profile inside the fuel bundle is flattened which will obviously decrease the peak cladding temperature. The distributed resistance model for wire wrap was developed and implemented in ATHAS subchannel analysis code. The HPLWR wire wrapped assembly was analyzed. The results show that: (1 the assembly with wire wrap can obtain a more uniform coolant temperature profile than the grid spaced assembly, which will result in a lower peak cladding temperature; (2 the pressure drop in a wire wrapped assembly is less than that in a grid spaced assembly, which can reduce the operating power of pump effectively; (3 the wire wrap pitch has significant effect on the flow in the assembly. Smaller Hwire/Drod will result in stronger cross flow a more uniform coolant temperature profile, and also a higher pressure drop.

  20. Superconducting wires and methods of making thereof

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xingchen; Sumption, Michael D.; Peng, Xuan

    2018-03-13

    Disclosed herein are superconducting wires. The superconducting wires can comprise a metallic matrix and at least one continuous subelement embedded in the matrix. Each subelement can comprise a non-superconducting core, a superconducting layer coaxially disposed around the non-superconducting core, and a barrier layer coaxially disposed around the superconducting layer. The superconducting layer can comprise a plurality of Nb.sub.3Sn grains stabilized by metal oxide particulates disposed therein. The Nb.sub.3Sn grains can have an average grain size of from 5 nm to 90 nm (for example, from 15 nm to 30 nm). The superconducting wire can have a high-field critical current density (J.sub.c) of at least 5,000 A/mm.sup.2 at a temperature of 4.2 K in a magnetic field of 12 T. Also described are superconducting wire precursors that can be heat treated to prepare superconducting wires, as well as methods of making superconducting wires.

  1. Si Wire-Array Solar Cells

    Science.gov (United States)

    Boettcher, Shannon

    2010-03-01

    Micron-scale Si wire arrays are three-dimensional photovoltaic absorbers that enable orthogonalization of light absorption and carrier collection and hence allow for the utilization of relatively impure Si in efficient solar cell designs. The wire arrays are grown by a vapor-liquid-solid-catalyzed process on a crystalline (111) Si wafer lithographically patterned with an array of metal catalyst particles. Following growth, such arrays can be embedded in polymethyldisiloxane (PDMS) and then peeled from the template growth substrate. The result is an unusual photovoltaic material: a flexible, bendable, wafer-thickness crystalline Si absorber. In this paper I will describe: 1. the growth of high-quality Si wires with controllable doping and the evaluation of their photovoltaic energy-conversion performance using a test electrolyte that forms a rectifying conformal semiconductor-liquid contact 2. the observation of enhanced absorption in wire arrays exceeding the conventional light trapping limits for planar Si cells of equivalent material thickness and 3. single-wire and large-area solid-state Si wire-array solar cell results obtained to date with directions for future cell designs based on optical and device physics. In collaboration with Michael Kelzenberg, Morgan Putnam, Joshua Spurgeon, Daniel Turner-Evans, Emily Warren, Nathan Lewis, and Harry Atwater, California Institute of Technology.

  2. Needleless electrospinning with twisted wire spinneret

    International Nuclear Information System (INIS)

    Holopainen, Jani; Penttinen, Toni; Santala, Eero; Ritala, Mikko

    2015-01-01

    A needleless electrospinning setup named ‘Needleless Twisted Wire Electrospinning’ was developed. The polymer solution is electrospun from the surface of a twisted wire set to a high voltage and collected on a cylindrical collector around the wire. Multiple Taylor cones are simultaneously self-formed on the downward flowing solution. The system is robust and simple with no moving parts aside from the syringe pump used to transport the solution to the top of the wire. The structure and process parameters of the setup and the results on the preparation of polyvinyl pyrrolidone (PVP), hydroxyapatite (HA) and bioglass fibers with the setup are presented. PVP fiber sheets with areas of 40 × 120 cm 2 and masses up to 1.15 g were prepared. High production rates of 5.23 g h −1 and 1.40 g h −1 were achieved for PVP and HA respectively. The major limiting factor of the setup is drying of the polymer solution on the wire during the electrospinning process which will eventually force to interrupt the process for cleaning of the wire. Possible solutions to this problem and other ways to develop the setup are discussed. The presented system provides a simple way to increase the production rate and area of fiber sheet as compared with the conventional needle electrospinning. (paper)

  3. A cycloidal wobble motor driven by shape memory alloy wires

    Science.gov (United States)

    Hwang, Donghyun; Higuchi, Toshiro

    2014-05-01

    A cycloidal wobble motor driven by shape memory alloy (SMA) wires is proposed. In realizing a motor driving mechanism well known as a type of reduction system, a cycloidal gear mechanism is utilized. It facilitates the achievement of bidirectional continuous rotation with high-torque capability, based on its high efficiency and high reduction ratio. The applied driving mechanism consists of a pin/roller based annular gear as a wobbler, a cycloidal disc as a rotor, and crankshafts to guide the eccentric wobbling motion. The wobbling motion of the annular gear is generated by sequential activation of radially phase-symmetrically placed SMA wires. Consequently the cycloidal disc is rotated by rolling contact based cycloidal gearing between the wobbler and the rotor. In designing the proposed motor, thermomechanical characterization of an SMA wire biased by extension springs is experimentally performed. Then, a simplified geometric model for the motor is devised to conduct theoretical assessment of design parametric effects on structural features and working performance. With consideration of the results from parametric analysis, a functional prototype three-phase motor is fabricated to carry out experimental verification of working performance. The observed experimental results including output torque, rotational speed, bidirectional positioning characteristic, etc obviously demonstrate the practical applicability and potentiality of the wobble motor.

  4. 75 FR 60480 - In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire...

    Science.gov (United States)

    2010-09-30

    ... COMMISSION In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire... importation, or the sale within the United States after importation of certain bulk welding wire containers, components thereof, and welding wire by reason of infringement of certain claims of United States Patent Nos...

  5. Empolder and application of LiveWire program

    International Nuclear Information System (INIS)

    Zhang Bo; Li Jing; Wang Xiaoming

    2007-01-01

    LiveWire is a specific module of Netscape Web server to actualize CGI function; through LiveWire application program one can create dynamic web page on web site. This article introduces how to write LiveWire application code, have to compile, debug and manage LiveWire application programs, and how to apply LiveWire application program on Netscape Web server to create a dynamic web page. (authors)

  6. Wiring design for the control of electromagnetic interference (EMI)

    Science.gov (United States)

    Kopasakis, George

    1995-01-01

    Wiring design is only one important aspect of EMI control. Other important areas for EMI are: circuit design, filtering, grounding, bonding, shielding, lighting, electrostatic discharge (ESD), transient suppression, and electromagnetic pulse (EMP). Topics covered include: wire magnetic field emissions at low frequencies; wire radiated magnetic field emissions at frequencies; wire design guidelines for EMI control; wire design guidelines for EMI control; high frequency emissions from cables; and pulse frequency spectra.

  7. A survey of the prevalence of blowfly strike and the control measures used in the Rûens area of the Western Cape Province of South Africa

    Directory of Open Access Journals (Sweden)

    A. J. Scholtz

    2011-04-01

    Full Text Available Blowfly strike and the methods used to combat blowfly strike were recorded on 33 properties in the Rûens area of South Africa during 2003/2004. Data were recorded on Merino and Dohne Merino hoggets (n = 4951 with at least 3 months’ wool growth. The following data were captured: presence or absence of strike, site of the strike (body or breech, presence or absence of dermatophilosis as well as subjective scores for wool quality and wool colour. Control measures recorded include: chemical treatment (preventative and spot treatment, crutching, mulesing and the use of the Lucitrap® system. Blowfly strike was not significantly influenced by gender or breed. Hoggets suffering from dermatophilosis were more likely to be struck, compared with contemporaries not suffering from the skin disorder (0.057 vs 0.027; P < 0.05. Merino hoggets generally had higher scores than their Dohne Merino contemporaries for wool quality (32.6 vs 27.4; P<0.05 and wool colour (29.0 vs 27.2; P<0.05. There was an indication that the Lucitrap® system may have reduced flystrike, but the effect was not statistically significant (P = 0.19 for overall strikes and P = 0.12 for body strike. The Mules operation benefited overall flystrike (0.013 vs 0.110; P < 0.05; mainly through an effect on breech strike (0.010 vs 0.109; P < 0.05. The proportion of fly strikes increased with wool length, and declined with an increase in farm size in wool colour score. None of the ethically acceptable control measures assessed could substantially reduce blowfly strike on their own, and an integrated pest management programme was proposed.

  8. Remarkable rates of lightning strike mortality in Malawi.

    Directory of Open Access Journals (Sweden)

    Monique Borgerhoff Mulder

    Full Text Available Livingstone's second mission site on the shore of Lake Malawi suffers very high rates of consequential lightning strikes. Comprehensive interviewing of victims and their relatives in seven Traditional Authorities in Nkhata Bay District, Malawi revealed that the annual rate of consequential strikes was 419/million, more than six times higher than that in other developing countries; the rate of deaths from lightning was 84/million/year, 5.4 times greater than the highest ever recorded. These remarkable figures reveal that lightning constitutes a significant stochastic source of mortality with potential life history consequences, but it should not deflect attention away from the more prominent causes of mortality in this rural area.

  9. Legal questions surrounding hunger strikes by detainees and prisoners.

    Science.gov (United States)

    Strauss, S A

    1991-01-01

    The 'right to die' is not of an absolute character but is subject to definite qualification. There are legal and social interests reflecting profound ethical values which militate against an absolute right on the part of a prisoner to die by means of a hunger strike. The declared policy of the South African authorities is that a prisoner who resorts to a hunger strike may not be subjected to force-feeding. This is in accordance with the 1975 Tokyo Declaration. Unfortunately the Declaration is silent on the question of whether a doctor may provide medical treatment once a hunger striker has reached the point where he is no longer capable of rational thought. In this article it is submitted that a doctor would be legally entitled to do so.

  10. Single Station System and Method of Locating Lightning Strikes

    Science.gov (United States)

    Medelius, Pedro J. (Inventor); Starr, Stanley O. (Inventor)

    2003-01-01

    An embodiment of the present invention uses a single detection system to approximate a location of lightning strikes. This system is triggered by a broadband RF detector and measures a time until the arrival of a leading edge of the thunder acoustic pulse. This time difference is used to determine a slant range R from the detector to the closest approach of the lightning. The azimuth and elevation are determined by an array of acoustic sensors. The leading edge of the thunder waveform is cross-correlated between the various acoustic sensors in the array to determine the difference in time of arrival, AT. A set of AT S is used to determine the direction of arrival, AZ and EL. The three estimated variables (R, AZ, EL) are used to locate a probable point of the lightning strike.

  11. Control of striking velocity by table tennis players.

    Science.gov (United States)

    Marinovic, Welber; Iizuka, Cristina Akiko; Freudenheim, Andrea Michele

    2004-12-01

    This study investigated how 7 skilled table tennis players controlled velocity of a forehand drive stroke when the ball's trajectory, velocity, and spin were modified. They hit a target in response to balls launched under four different conditions. The relative and absolute times used in the backswing phase showed no significant differences among conditions. When subjects hit fastballs, there was a significant change in the time required for them to reach the peak of velocity in the forward swing phase. In addition, players decreased the velocity of their strokes to hit fast-approaching balls. These results indicate that highly skilled table tennis players need to adjust the striking velocity and striking time (relative and absolute) required to reach the peak of velocity in the forward swing phase for these task modifications. Since they used slower movement velocities to hit faster-approaching balls, skilled table tennis players may override this speed-coupling process.

  12. Simulating Bird Strike on Aircraft Composite Wing Leading Edge.

    OpenAIRE

    Ericsson, Max

    2012-01-01

    In this master thesis project the possibility to model the response of a wing when subjected to bird strike using finite elements is analyzed. Since this transient event lasts only a few milliseconds the used solution method is explicit time integration. The wing is manufactured using carbon fiber laminate. Carbon fiber laminates have orthotropic material properties with different stiffness in different directions. Accordingly, there are damage mechanisms not considered when using metal that ...

  13. Genetic Control of Wiring Specificity in the Fly Olfactory System

    Science.gov (United States)

    Hong, Weizhe; Luo, Liqun

    2014-01-01

    Precise connections established between pre- and postsynaptic partners during development are essential for the proper function of the nervous system. The olfactory system detects a wide variety of odorants and processes the information in a precisely connected neural circuit. A common feature of the olfactory systems from insects to mammals is that the olfactory receptor neurons (ORNs) expressing the same odorant receptor make one-to-one connections with a single class of second-order olfactory projection neurons (PNs). This represents one of the most striking examples of targeting specificity in developmental neurobiology. Recent studies have uncovered central roles of transmembrane and secreted proteins in organizing this one-to-one connection specificity in the olfactory system. Here, we review recent advances in the understanding of how this wiring specificity is genetically controlled and focus on the mechanisms by which transmembrane and secreted proteins regulate different stages of the Drosophila olfactory circuit assembly in a coordinated manner. We also discuss how combinatorial coding, redundancy, and error-correcting ability could contribute to constructing a complex neural circuit in general. PMID:24395823

  14. Mixed and dynamic response of hot wires and cold wires and measurements of turbulence statistics

    DEFF Research Database (Denmark)

    Larsen, Søren Ejling; Højstrup, Jørgen; Fairall, C. W.

    1986-01-01

    Hot wires respond to temperature as well as to velocity, whereas cold wires respond to velocity as well as to temperature. The static and dynamic response characteristics are summarized and it is shown that the frequency transfer functions for the four different responses in general are different...

  15. STRS SpaceWire FPGA Module

    Science.gov (United States)

    Lux, James P.; Taylor, Gregory H.; Lang, Minh; Stern, Ryan A.

    2011-01-01

    An FPGA module leverages the previous work from Goddard Space Flight Center (GSFC) relating to NASA s Space Telecommunications Radio System (STRS) project. The STRS SpaceWire FPGA Module is written in the Verilog Register Transfer Level (RTL) language, and it encapsulates an unmodified GSFC core (which is written in VHDL). The module has the necessary inputs/outputs (I/Os) and parameters to integrate seamlessly with the SPARC I/O FPGA Interface module (also developed for the STRS operating environment, OE). Software running on the SPARC processor can access the configuration and status registers within the SpaceWire module. This allows software to control and monitor the SpaceWire functions, but it is also used to give software direct access to what is transmitted and received through the link. SpaceWire data characters can be sent/received through the software interface, as well as through the dedicated interface on the GSFC core. Similarly, SpaceWire time codes can be sent/received through the software interface or through a dedicated interface on the core. This innovation is designed for plug-and-play integration in the STRS OE. The SpaceWire module simplifies the interfaces to the GSFC core, and synchronizes all I/O to a single clock. An interrupt output (with optional masking) identifies time-sensitive events within the module. Test modes were added to allow internal loopback of the SpaceWire link and internal loopback of the client-side data interface.

  16. Strength of stainless steel surgical wire in various fixation modes.

    Science.gov (United States)

    Schultz, R S; Boger, J W; Dunn, H K

    1985-09-01

    Although wire is a commonly used fixation device in orthopedics, little is known about the effects of fastening methods and configurations on the strength of wiring systems. Three sizes of stainless steel surgical wire were tested in noncyclic tensile loading. Load failure levels increased with enlarging wire diameter. Fastening twists were stronger than knots or the ASIF bend technique. The failure mode for twists was untwisting. More than two twists gave no additional strength to the system. Two commercial wire tightening devices gave stronger and more reproducible twists than did ordinary pliers. The addition of a tension equalizing loop opposite the fastening loop weakened the wire system by 10%-15%. The combination of two single wire loops was stronger than a continuous double loop of wire. The results from this study are intended to help the orthopedic surgeon optimize the use of wire.

  17. Integrated Electrical Wire Insulation Repair System

    Science.gov (United States)

    Williams, Martha; Jolley, Scott; Gibson, Tracy; Parks, Steven

    2013-01-01

    An integrated system tool will allow a technician to easily and quickly repair damaged high-performance electrical wire insulation in the field. Low-melt polyimides have been developed that can be processed into thin films that work well in the repair of damaged polyimide or fluoropolymer insulated electrical wiring. Such thin films can be used in wire insulation repairs by affixing a film of this low-melt polyimide to the damaged wire, and heating the film to effect melting, flow, and cure of the film. The resulting repair is robust, lightweight, and small in volume. The heating of this repair film is accomplished with the use of a common electrical soldering tool that has been modified with a special head or tip that can accommodate the size of wire being repaired. This repair method can furthermore be simplified for the repair technician by providing replaceable or disposable soldering tool heads that have repair film already "loaded" and ready for use. The soldering tool heating device can also be equipped with a battery power supply that will allow its use in areas where plug-in current is not available

  18. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  19. Percutaneous tension band wiring for patellar fractures.

    Science.gov (United States)

    Rathi, Akhilesh; Swamy, M K S; Prasantha, I; Consul, Ashu; Bansal, Abhishek; Bahl, Vibhu

    2012-08-01

    To evaluate outcome of percutaneous tension band wiring for transverse fractures of the patella. 16 men and 7 women aged 27 to 65 (mean, 40) years underwent percutaneous tension band wiring for transverse fractures of the patella with a displacement of >3 mm. Pain, operating time, mobility, functional score, and complications were evaluated. 20 patients underwent successful percutaneous tension band wiring. The remaining 3 patients in whom closed reduction failed underwent open reduction and tension band wiring. The mean operating time was 46 (range, 28-62) minutes. The mean follow-up period was 20 (range, 15-30) months. At the latest follow-up, all patients had regained full extension. The objective score was excellent in 20 patients and good in 3, whereas the subjective score was excellent in 17, good in 5, and fair in one. All patients had radiological union at week 8. One patient had patellofemoral arthritis (secondary to a postoperative articular step). Two patients developed superficial infections, which resolved after antibiotic therapy. Mean thigh muscle wasting was 0.7 (range, 0.4-1) cm. Three patients encountered hardware problems (impingement/irritation of the skin over the knee) necessitating implant removal. Percutaneous tension band wiring is a viable option for transverse fractures of the patella.

  20. Effect of Size on Tensile Strength of Fine Polycrystalline Nickel Wires

    National Research Council Canada - National Science Library

    Rubenstein, Lester

    1966-01-01

    .... The tensile strength of recrystallized wires was diameter independent. The proportional limit stress of recrystallized wires was inversely related to power functions of wire diameter and grain size...

  1. Assessment of bone healing on tibial fractures treated with wire osteosynthesis associated or not with infrared laser light and biphasic ceramic bone graft (HATCP) and guided bone regeneration (GBR): Raman spectroscopy study

    Science.gov (United States)

    Bastos de Carvalho, Fabíola; Aciole, Gilberth Tadeu S.; Aciole, Jouber Mateus S.; Silveira, Landulfo, Jr.; Nunes dos Santos, Jean; Pinheiro, Antônio L. B.

    2011-03-01

    The aim of this study was to evaluate, through Raman spectroscopy, the repair of complete tibial fracture in rabbits fixed with wire osteosynthesis - WO, treated or not with infrared laser light (λ 780nm, 50mW, CW) associated or not to the use of HATCP and GBR. Surgical fractures were created under general anesthesia (Ketamine 0.4ml/Kg IP and Xilazine 0.2ml/Kg IP), on the tibia of 15 rabbits that were divided into 5 groups and maintained on individual cages, at day/night cycle, fed with solid laboratory pelted diet and had water ad libidum. On groups II, III, IV and V the fracture was fixed with WO. Animals of groups III and V were grafted with hydroxyapatite + GBR technique. Animals of groups IV and V were irradiated at every other day during two weeks (16J/cm2, 4 x 4J/cm2). Observation time was that of 30 days. After animal death the specimens were kept in liquid nitrogen for further analysis by Raman spectroscopy. Raman spectroscopy showed significant differences between groups (p<0.001). It is concluded that IR laser light was able to accelerate fracture healing and the association with HATCP and GBR resulted on increased deposition of calcium hydroxyapatite.

  2. Magnetic wires in MEMS and bio-medical applications

    International Nuclear Information System (INIS)

    Barbic, Mladen

    2002-01-01

    Magnetic wires of appropriate design have special features making them useful to micro-electromechanical systems and bio-medical applications. Several applications that exploit the properties of magnetic wires are reviewed including: (a) a magnetic micro-manipulation technique that utilizes integrated micro-coils and magnetic micro-wires for localized positioning of micron-sized magnetic objects, (b) integrated micro-coil/micro-wire system operating as a micro-fluidic micro-motor, (c) mechanical tweezers using magneto-static interaction between two magnetic micro-wires, and (d) ultra-high gradient magnetic separation system based on porous membranes partially filled with magnetic wires

  3. A comparison of a 'J' wire and a straight wire in successful antegrade cannulation of the superficial femoral artery

    International Nuclear Information System (INIS)

    Gay, D.A.T.; Edwards, A.J.; Puckett, M.A.; Roobottom, C.A.

    2005-01-01

    AIMS: To evaluate the success of two different types of wire in common use in their ability to successfully cannulate the superficial femoral artery (SFA) using antegrade puncture. METHODS: 50 consecutive patients in whom antegrade infra-inguinal intervention was planned, underwent common femoral arterial puncture and then cannulation with either a standard 3 mm 'J' wire or a floppy tipped straight wire (William Cook--Europe). The frequency with which each type of wire entered the SFA or profunda femoris artery without image guidance was recorded. Further analysis was also made of the success of manipulation of the wire into the SFA following profunda cannulation and the use of alternative guide wires. RESULTS: In 19 out of 25 (76%) patients the 'J' wire correctly entered the SFA without image guidance. Only 5 out of 25 (25%) of straight wires entered the SFA with the initial pass (p<0.0001). Following further manipulation with the same wire all except 1 'J' wire was successfully negotiated into the SFA. The same was true for only 9 of the remaining straight wires with 11 patients requiring an alternative guide wire. CONCLUSIONS: When performing antegrade cannulation of the SFA a 'J' wire is more likely to be successful than a straight guide wire

  4. Cockpit canopy shattering using exploding wire techniques

    International Nuclear Information System (INIS)

    Novac, B M; Smith, I R; Downs, P R; Marston, P; Fahey, D

    2007-01-01

    This paper presents the principal experimental results provided by a preliminary investigation into the possibility of using exploding wire (EW) techniques to shatter the plastic cockpit canopy of a modern jet aircraft. The data provided forms the basis for a qualitative understanding of the physics of interaction between the plasma produced by an EW and the surrounding elasto-plastic material in which the wire is embedded. To optimize the shock-wave 'clean cutting' effect, the significance of the material, the dimensions of the exploding wire and the amplitude of the current and voltage pulses are all considered. This leads to important conclusions concerning both the characteristics of the EW and the optimum arrangement of the electrical circuit, with the single most important optimization factor being the peak electrical power input to the EW, rather than the dissipated Joule energy. A full-scale system relevant to an actual cockpit canopy shattering is outlined and relevant results are presented and discussed

  5. Reusable Hot-Wire Cable Cutter

    Science.gov (United States)

    Pauken, Michael T.; Steinkraus, Joel M.

    2010-01-01

    During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which

  6. Investigation of method for Stainless Steel Welding Wire as a Replacement for Arc Wire Comsumables

    Directory of Open Access Journals (Sweden)

    Koiprasert, H.

    2005-01-01

    Full Text Available Arc spraying as a coating method is being employed in various industrial applications as a part of maintenance service, and also as a surface engineering technique for many machine parts and components. The major cost in producing the arc spray coating is, however, based on the cost of the arc wire comsumables. This project was carried out to investigate the use of the commercially-available gas metal arc welding wire (GMAW wire as a cheaper alternative to the special-purpose arc wire comsumables. The wire material chosen for this early study is the 316L stainless steel, due to its popularity in many applications as a built-up coating for worn parts. The physical properties of the coatings produced from the two sets of 316L stainless steel wire were determined to be different in the percentage of porosity and the oxide content. The mechanical properties, including the tensile bond strength and the wear rate of the coatings produced from the two types of sprayed wire, were also different. This will, in turn, result in a slight difference in the performance of thecoatings.

  7. Modeling of Service-Drop Wires and Interior-Wiring Cables for Lightning Overvoltage Studies

    Science.gov (United States)

    Matsuura, Susumu; Noda, Taku; Nakamura, Masatoshi; Sakai, Hiroshi

    As the information society progresses, a variety of electronic appliances have come into wide use in common houses. If a lightning stroke causes faults or incorrect operations of these electronic appliances, a social economic loss is considered to be large. For this reason, the focus of lightning protection measures for distribution lines in Japan has expanded to include the low-voltage side of the distribution line in addition to the high-voltage side. In order to calculate lightning overvoltages at the low-voltage side, the surge characteristics of service-drop wires and interior-wiring cables have to be modeled accurately. First, this paper describes test results of the surge characteristics of service-drop wires and interior-wiring cables. The modal surge impedances and the propagation velocities of various service-drop wires and interior-wiring cables are obtained by the test. Based on the test results obtained, this paper proposes a modeling methodology of these wires and cables for accurate EMTP (Electro-Magnetic Transients Program) lightning overvoltage simulations. The proposed model is validated by comparing EMTP simulation results with field test results.

  8. Quantum conductance in silicon quantum wires

    CERN Document Server

    Bagraev, N T; Klyachkin, L E; Malyarenko, A M; Gehlhoff, W; Ivanov, V K; Shelykh, I A

    2002-01-01

    The results of investigations of electron and hole quantum conductance staircase in silicon quantum wires are presented. The characteristics of self-ordering quantum wells of n- and p-types, which from on the silicon (100) surface in the nonequilibrium boron diffusion process, are analyzed. The results of investigations of the quantum conductance as the function of temperature, carrier concentration and modulation degree of silicon quantum wires are given. It is found out, that the quantum conductance of the one-dimensional channels is observed, for the first time, at an elevated temperature (T >= 77 K)

  9. Numerical Simulation of Wire-Coating

    DEFF Research Database (Denmark)

    Wapperom, Peter; Hassager, Ole

    1999-01-01

    A finite element program has been used to analyze the wire-coating process of an MDPE melt. The melt is modeled by a nonisothermal Carreau model. The emphasis is on predicting an accurate temperature field. Therefore, it is necessary to include the heat conduction in the metal parts. A comparison...... is made with the results of a simulation that models the heat conduction in the metal head by means of a Biot boundary condition. The influence of the wire velocity, inlet temperature and power-law index will be examined....

  10. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery.

    Science.gov (United States)

    Oh, You Na; Ha, Keong Jun; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won

    2015-08-01

    Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578), major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99), minor wound complications (3.6% vs. 2.0%, p=0.279), or mediastinitis (0.8% vs. 1.0%, p=1.00). Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068). The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  11. Comparison of subtransverse process wiring and sublaminar wiring in the treatment of idiopathic thoracic scoliosis.

    Science.gov (United States)

    Akmeşe, Ramazan; Kemal Us, Ali

    2013-04-01

    A retrospective study. The objectives of this study were to show the advantages of an alternative segmental spinal instrumentation technique, termed subtransverse process wiring, and compare it with a sublaminar wiring technique in the treatment of idiopathic thoracic scoliosis. High rates of neurological complications and the need for high experience limit the use of the sublaminar wiring technique, although it is an effective segmental spinal instrumentation technique in the treatment of scoliosis. This is the first study to correlate sublaminar wiring and subtransverse process wiring techniques clinically. In a retrospective study, 64 patients with idiopathic thoracic scoliosis were chosen randomly. Nineteen patients were treated with subtransverse process wires (group A), and 45 patients were treated with sublaminar wires (group B). The mean follow-up period was 50.9 months (25 to 90 mo) in group A and 57.9 months (26 to 108 mo) in group B. The average deformity correction was 26.5 degrees (52.9%) in group A and 28.9 degrees (54.1%) in group B. The average correction loss was 2.9 degrees (17.2%) in group A and 6.4 degrees (27%) in group B. None of the patients developed neurological complications in group A. In group B, 5 (11.1%) intraoperative dural tears, 4 (8.9%) neurological deficits, and 8 (14.4%) transient dysesthesia syndromes were seen. The average operation time was 3.6 hours (3 to 4 h) in group A and 4.9 hours (3.75 to 8 h) in group B. The average replacement of blood (erythrocyte suspension) was 2.9 U (2 to 5 U) in group A and 3.1 U (2 to 6 U) in group B. Sublaminar wiring is a time-consuming technique with high risks of neurological complications, whereas subtransverse process wiring is an easy and neurologically safe method, which maintains effective deformity correction and stability of the correction.

  12. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    You Na Oh

    2015-08-01

    Full Text Available Background: Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Methods: Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Results: Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578, major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99, minor wound complications (3.6% vs. 2.0%, p=0.279, or mediastinitis (0.8% vs. 1.0%, p=1.00. Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068. Conclusion: The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  13. Magnetic anisotropy and anisotropic ballistic conductance of thin magnetic wires

    International Nuclear Information System (INIS)

    Sabirianov, R.

    2006-01-01

    The magnetocrystalline anisotropy of thin magnetic wires of iron and cobalt is quite different from the bulk phases. The spin moment of monatomic Fe wire may be as high as 3.4 μ B , while the orbital moment as high as 0.5 μ B . The magnetocrystalline anisotropy energy (MAE) was calculated for wires up to 0.6 nm in diameter starting from monatomic wire and adding consecutive shells for thicker wires. I observe that Fe wires exhibit the change sign with the stress applied along the wire. It means that easy axis may change from the direction along the wire to perpendicular to the wire. We find that ballistic conductance of the wire depends on the direction of the applied magnetic field, i.e. shows anisotropic ballistic magnetoresistance. This effect occurs due to the symmetry dependence of the splitting of degenerate bands in the applied field which changes the number of bands crossing the Fermi level. We find that the ballistic conductance changes with applied stress. Even for thicker wires the ballistic conductance changes by factor 2 on moderate tensile stain in our 5x4 model wire. Thus, the ballistic conductance of magnetic wires changes in the applied field due to the magnetostriction. This effect can be observed as large anisotropic BMR in the experiment

  14. EDITORIAL More than a wire More than a wire

    Science.gov (United States)

    Demming, Anna

    2010-10-01

    Nanowires are the natural evolution of the connections in circuits when scaled down to nanometre sizes. On closer inspection, of course, the role of nanowires in developing new technologies is much more than just a current-bearing medium. By sizing the diameters of these objects down to the nanoscale, their properties become increasingly sensitive to factors such as the gas composition, temperature and incident light of their surrounding environment, as well as defects and variations in diameter. What becomes important in modern electronics innovations is not just what is connected, but how. Nanowires had already begun to attract the attention of researchers in the early 1990s as advances in imaging and measurement devices invited researchers to investigate the properties of these one-dimensional structures [1, 2]. This interest has sparked ingenious ways of fabricating nanowires such as the use of a DNA template. A collaboration of researchers at Louisiana Tech University in the US hs provided an overview of various methods to assemble conductive nanowires on a DNA template, including a summary of different approaches to stretching and positioning the templates [3]. Work in this area demonstrates a neat parallel for the role of DNA molecules as the building blocks of life and the foundations of nanoscale device architectures. Scientists at HP Labs in California are using nanowires to shrink the size of logic arrays [4]. One aspect of electronic interconnects that requires particular attention at nanoscale sizes is the effect of defects. The researchers at HP Labs demonstrate that their approach, which they name FPNI (field-programmable nanowire interconnect), is extremely tolerant of the high defect rates likely to be found in these nanoscale structures, and allows reduction in size and power without significantly sacrificing the clock rate. Another issue in scaling down electronics is the trend for an increasing resistivity with decreasing wire width. Researchers

  15. Evolution of cementite morphology in pearlitic steel wire during wet wire drawing

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2010-01-01

    decreasing from 19 nm (ε = 0) to 2 nm (ε = 3.7) in correspondence with the reduction in wire diameter. The deformation of the cementite is strongly related to plastic deformation in the ferrite, with coarse slip steps, shear bands and cracks in the cementite plates/particles observed parallel to either {110...... microscope observations show that cementite plates become increasingly aligned with the wire axis as the drawing strain is increased. Measurements in the transmission electron microscope show that the cementite deforms plastically during wire drawing , with the average thickness of the cementite plates...

  16. Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires

    OpenAIRE

    Tada, Yoshifumi; Hayakawa, Tohru; Nakamura, Yoshiki

    2017-01-01

    Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 ? 0.022 in2 and 0.019 ? 0.025 in2 (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bendin...

  17. PSpice Model of Lightning Strike to a Steel Reinforced Structure

    International Nuclear Information System (INIS)

    Koone, Neil; Condren, Brian

    2003-01-01

    Surges and arcs from lightning can pose hazards to personnel and sensitive equipment, and processes. Steel reinforcement in structures can act as a Faraday cage mitigating lightning effects. Knowing a structure's response to a lightning strike allows hazards associated with lightning to be analyzed. A model of lightning's response in a steel reinforced structure has been developed using PSpice (a commercial circuit simulation). Segments of rebar are modeled as inductors and resistors in series. A program has been written to take architectural information of a steel reinforced structure and 'build' a circuit network that is analogous to the network of reinforcement in a facility. A severe current waveform (simulating a 99th percentile lightning strike), modeled as a current source, is introduced in the circuit network, and potential differences within the structure are determined using PSpice. A visual three-dimensional model of the facility displays the voltage distribution across the structure using color to indicate the potential difference relative to the floor. Clear air arcing distances can be calculated from the voltage distribution using a conservative value for the dielectric breakdown strength of air. Potential validation tests for the model will be presented

  18. Recent geodynamics of major strike-slip zones

    Directory of Open Access Journals (Sweden)

    Vladimir G. Trifonov

    2015-09-01

    In all of the cases mentioned above, strike-slip deformation was expressed only or mainly during strong earthquakes. At other times, the rate of its accumulation was small and the dominant stress conditions led to transverse shortening, rarely resulting in local lengthening of the tectonic zone. These variations are caused by the tectonic peculiarities of these zones. The sinistral component of the deformation is related to the shift of the Arabian Plate relative to the African one, but also the transverse component is related to the continental slope and is expressed by the Coastal range shortening that exists in the El Ghab segment zone. There is not only a dextral deformation component, but also a transverse component, expressed by shortening of the Fergana and Talas ranges existing in the Talas-Fergana fault zone. In both zones, the shortening component became appreciable or dominant when the strike-slip deformation rate decreased. Similar, but more local, relationships were expressed in the epicentral area of the 2003 Altai earthquake and in the Western Palmyrides.

  19. Onset of aseismic creep on major strike-slip faults

    KAUST Repository

    Çakir, Ziyadin

    2012-10-02

    Time series analysis of spaceborne synthetic aperture radar (SAR) data, GPS measurements, and fi eld observations reveal that the central section of the Izmit (Turkey) fault that slipped with a supershear rupture velocity in the A.D. 1999, Mw7.4, Izmit earthquake began creeping aseismically following the earthquake. Rapid initial postseismic afterslip decayed logarithmically with time and appears to have reached a steady rate comparable to the preearthquake full fault-crossing rate, suggesting that it may continue for decades and possibly until late in the earthquake cycle. If confi rmed by future monitoring, these observations identify postseismic afterslip as a mechanism for initiating creep behavior along strike-slip faults. Long-term afterslip and/or creep has signifi cant implications for earthquake cycle models, recurrence intervals of large earthquakes, and accordingly, seismic hazard estimation along mature strike-slip faults, in particular for Istanbul which is believed to lie adjacent to a seismic gap along the North Anatolian fault in the Sea of Marmara. © 2012 Geological Society of America.

  20. Influence of strike object grounding on close lightning electric fields

    Science.gov (United States)

    Baba, Yoshihiro; Rakov, Vladimir A.

    2008-06-01

    Using the finite difference time domain (FDTD) method, we have calculated vertical electric field Ez, horizontal (radial) electric field Eh, and azimuthal magnetic field Hϕ produced on the ground surface by lightning strikes to 160-m- and a 553-m-high conical strike objects representing the Peissenberg tower (Germany) and the CN Tower (Canada), respectively. The fields were computed for a typical subsequent stroke at distances d' from the bottom of the object ranging from 5 to 100 m for the 160-m tower and from 10 to 300 m for the 553-m tower. Grounding of the 160-m object was assumed to be accomplished by its underground basement represented by a 10-m-radius and 8-m-long perfectly conducting cylinder with or without a reference ground plane located 2 m below. The reference ground plane simulates, to some extent, a higher-conducting ground layer that is expected to exist below the water table. The configuration without reference ground plane actually means that this plane is present, but is located at an infinitely large depth. Grounding of the 553-m object was modeled in a similar manner but in the absence of reference ground plane only. In all cases considered, waveforms of Eh and Hϕ are not much influenced by the presence of strike object, while waveforms of Ez are. Waveforms of Ez are essentially unipolar (as they are in the absence of strike object) when the ground conductivity σ is 10 mS/m (the equivalent transient grounding impedance is several ohms) or greater. Thus, for the CN Tower, for which σ ≥ 10 mS/m, the occurrence of Ez polarity change is highly unlikely. For the 160-m tower and for σ = 1 and 0.1 mS/m, waveforms of Ez become bipolar (exhibit polarity change) at d' ≤ 10 m and d' ≤ 50 m, respectively, regardless of the presence of the reference ground plane. The corresponding equivalent transient grounding impedances are about 30 and 50 Ω in the absence of the reference ground plane and smaller than 10 Ω in the presence of the reference

  1. Ion Release and Galvanic Corrosion of Different Orthodontic Brackets and Wires in Artificial Saliva.

    Science.gov (United States)

    Tahmasbi, Soodeh; Sheikh, Tahereh; Hemmati, Yasamin B

    2017-03-01

    To investigate the galvanic corrosion of brackets manufactured by four different companies coupled with stainless steel (SS) or nickel-titanium (NiTi) wires in an artificial saliva solution. A total of 24 mandibular central incisor Roth brackets of four different manufacturers (American Orthodontics, Dentaurum, Shinye, ORJ) were used in this experimental study. These brackets were immersed in artificial saliva along with SS or NiTi orthodontic wires (0.016'', round) for 28 days. The electric potential difference of each bracket/ wire coupled with a saturated calomel reference electrode was measured via a voltmeter and recorded constantly. Corrosion rate (CR) was calculated, and release of ions was measured with an atomic absorption spectrometer. Stereomicroscope was used to evaluate all samples. Then, samples with corrosion were further assessed by scanning electron microscope and energy-dispersive X-ray spectroscopy. Two-way analysis of variance was used to analyze data. Among ions evaluated, release of nickel ions from Shinye brackets was significantly higher than that of other brackets. The mean potential difference was significantly lower in specimens containing a couple of Shinye brackets and SS wire compared with other specimens. No significant difference was observed in the mean CR of various groups (p > 0.05). Microscopic evaluation showed corrosion in two samples only: Shinye bracket coupled with SS wire and American Orthodontics bracket coupled with NiTi wire. Shinye brackets coupled with SS wire showed more susceptibility to galvanic corrosion. There were no significant differences among specimens in terms of the CR or released ions except the release of Ni ions, which was higher in Shinye brackets.

  2. STRUCTURE AND CHARACTERISTICS OF PATENTED HIGH-CARBON WIRE

    Directory of Open Access Journals (Sweden)

    A. Ju. Borisenko

    2011-01-01

    Full Text Available The influence of bainite structure on mechanical characteristics of wire of steel 80 after patenting is studied. The quantity and structure state of bainite, providing high complex of mechanical characteristics of high-carbon wire, is determined.

  3. Spectroscopic properties of colloidal indium phosphide quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lin-Wang; Wang, Fudong; Yu, Heng; Li, Jingbo; Hang, Qingling; Zemlyanov, Dmitry; Gibbons, Patrick C.; Wang, Lin-Wang; Janes, David B.; Buhro, William E.

    2008-07-11

    Colloidal InP quantum wires are grown by the solution-liquid-solid (SLS) method, and passivated with the traditional quantum dots surfactants 1-hexadecylamine and tri-n-octylphosphine oxide. The size dependence of the band gaps in the wires are determined from the absorption spectra, and compared to other experimental results for InP quantum dots and wires, and to the predictions of theory. The photoluminescence behavior of the wires is also investigated. Efforts to enhance photoluminescence efficiencies through photochemical etching in the presence of HF result only in photochemical thinning or photo-oxidation, without a significant influence on quantum-wire photoluminescence. However, photo-oxidation produces residual dot and rod domains within the wires, which are luminescent. The results establish that the quantum-wire band gaps are weakly influenced by the nature of the surface passivation, and that colloidal quantum wires have intrinsically low photoluminescence efficiencies.

  4. The Effect of Wire Dimension, Type and Thickness of Coating Layer on Friction of Coated Stainless-Steel Arch Wires

    Directory of Open Access Journals (Sweden)

    Ahmed Abdulhussain Abbas

    2018-03-01

    Full Text Available Background/Purpose: Esthetic coated arch wires are the desired types to match esthetic brackets in the clinical orthodontics, but the presence of coating layer is greatly affect friction during sliding mechanics. The aims of this study were to evaluate the effect of total wire dimension with the type and thickness of coating layer on friction of coated stainless-steel wires. Methods: The sample of this study consisted of 140 segments of coated stainless-steel arch wires involving two wire dimensions (0.016 × 0.022 inch and 0.019 × 0.025 inch. The samples were supplied from seven companies (DB, RMO, TP, DANY, G&H, Highland and Hubit and the uncoated control samples were supplied from IOS company. Wire dimensions and thickness of coating layer were measured by the metallurgical light incident microscope and the static frictional force was measured using pulling the wire through set of ceramic brackets by the universal testing machine. The data were then statistically analyzed using ANOVA tests. Results: Generally measured wire dimensions do not match the stated dimensions by the manufacturer. The frictional forces of coated wires differ from uncoated control being higher in the labially coated wires and lesser in the fully Teflon coated wires owing to differences in the wire dimension, thickness of coating layer, and physical properties of coating materials. Conclusion: when tested in vitro, Teflon fully coated wires produce the least amount of friction.

  5. Why forefoot striking in minimal shoes might positively change the course of running injuries

    Directory of Open Access Journals (Sweden)

    Irene S. Davis

    2017-06-01

    Full Text Available It is believed that human ancestors evolved the ability to run bipedally approximately 2 million years ago. This form of locomotion may have been important to our survival and likely has influenced the evolution of our body form. As our bodies have adapted to run, it seems unusual that up to 79% of modern day runners are injured annually. The etiology of these injuries is clearly multifactorial. However, 1 aspect of running that has significantly changed over the past 50 years is the footwear we use. Modern running shoes have become increasingly cushioned and supportive, and have changed the way we run. In particular, they have altered our footstrike pattern from a predominantly forefoot strike (FFS landing to a predominantly rearfoot strike (RFS landing. This change alters the way in which the body is loaded and may be contributing to the high rate of injuries runners experience while engaged in an activity for which they were adapted. In this paper, we will examine the benefits of barefoot running (typically an FFS pattern, and compare the lower extremity mechanics between FFS and RFS. The implications of these mechanical differences, in terms of injury, will be discussed. We will then provide evidence to support our contention that FFS provides an optimal mechanical environment for specific foot and ankle structures, such as the heel pad, the plantar fascia, and the Achilles tendon. The importance of footwear will then be addressed, highlighting its interaction with strike pattern on mechanics. This analysis will underscore why footwear matters when assessing mechanics. Finally, proper preparation and safe transition to an FFS pattern in minimal shoes will be emphasized. Through the discussion of the current literature, we will develop a justification for returning to running in the way for which we were adapted to reduce running-related injuries.

  6. The Diffusion of Strikes: A Dyadic Analysis of Economic Sectors in the Netherlands, 1995–2007

    NARCIS (Netherlands)

    Jansen, Giedo; Sluiter, Roderick; Akkerman, Agnes

    2016-01-01

    This study examines the extent to which strikes diffuse across sectors and to what extent this diffusion of strikes can be explained by similarities and interdependencies between sectors. For this purpose, the authors examine a unique temporally disaggregated and dyadic database on strikes in Dutch

  7. The Right to Strike in Public Employment. Key Issues Series--No. 15. Second Edition, Revised.

    Science.gov (United States)

    Sterret, Grace; Aboud, Antone

    Since the 1960s, the number of strikes by public employees, especially local government employees, has increased, and the number of employees belonging to unions or associations has about tripled. Recently, attention has been focused on strikes by public employees as a result of the strike in 1981 by air traffic controllers and their subsequent…

  8. Causes of falls of hangingwall over gullies adjacent to stabilizing strike pillars

    CSIR Research Space (South Africa)

    Turner, PA

    1987-08-01

    Full Text Available This report discusses the occurrence of falls of ground in strike gullies. Falls of hangingwall over strike gullies on the up-dip side of strike stabilizing pillars in longwall mining systems were investigated. Gullies were examined in both...

  9. Strikes in France and the Netherlands; A Comparison of Labour Market Institutions

    NARCIS (Netherlands)

    Butter, den F.A.G.; Koppes, S.Y.

    2003-01-01

    Strikes as a consequence of labour conflicts occur about 28 times as much in France as in the Netherlands. This paper examines the institutional differences underlying these differences in strike activity. Our empirical analysis shows that strike activity is high in France if workers were successful

  10. The development of ShortWatch, a novel overtemperature or mechanical damage sensing technology for wires or cables. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Ken; Morris, Jack; Wong, C.P.; Luo, Shijian

    2001-09-07

    'ShortWatch' is a patented technology which for the first time offers electrical wire/cable products providing real-time, 'in-situ' (1) condition monitoring that warns of insulation damage before an electrical fault occurs, (2) assessment of the ability to perform in a Design Basis event, (3) distributed sensor warning of overtemperature, and (4) insulation leakage measurement capability providing arc sensing and a reliable tool for wire age prediction.

  11. Acoustic Emission Monitoring of Compression-after-Impact Test of Nano-Particles-Coated CFRP Damaged by Simulated Lightning Strikes

    International Nuclear Information System (INIS)

    Shin, Je Ha; Kwon, Oh Yang; Seo, Seong Wook

    2011-01-01

    Nanoparticles-coated and impact-damaged carbon-fiber reinforced plastics(CFRP) laminates were tested under compression-after-impact(CAI) mode and the propagation of damage due to compressive loading has been monitored by acoustic emission(AE). The impact damage was induced not by mechanical loading but by a simulated lightning strike. CFRP laminates were made of carbon prepregs prepared by coating of conductive nano-particles directly on the fibers and the coupons were subjected to simulated lightning strikes with a high voltage/current impulse of 10∼40 kA within a few microseconds. The effects of nano-particles coating and the degree of damage induced by the simulated lightning strikes on the AE activities were examined, and the relationship between the compressive residual strength and AE behavior has been evaluated in terms of AE event counts and the onset of AE activity with the compressive loading. The degree of impact damage was also measured in terns of damage area by using ultrasonic C-scan images. From the results assessed during the CAI tests of damaged CFRP showed that AE monitoring appeared to be very useful to differentiate the degree of damage hence the mechanical integrity of composite structures damaged by lightning strikes

  12. Usefulness and limits of ultrasound guided hook-wire positioning for localisation of soft tissue lesions prior to surgery

    International Nuclear Information System (INIS)

    Trenaghi, Alberto; Dal Bosco, Chiara; Talenti, Enrico; Rubaltelli, Enrico; Borsato, Simonetta; Rossi, Carlo Riccardo; Lumachi, Franco

    2005-01-01

    Purpose. The aim of our study was to assess the usefulness of positioning metal wires under ultrasound guidance for localising soft tissue lesions in the preoperative phase. Materials and methods. We studied superficial soft-tissue lesions in 12 patients, using hooked mammographic wires of different lengths. One patient had a multifocal growth of disease which required a double localisation procedure. Correct positioning of the wire was confirmed by ultrasonography. All patients underwent surgery within five hours of hook-wire positioning. Results. Correct wire position was confirmed at surgery in 12 out of 13 procedures. In one case the hook-wire reached the margin of the lesion. In all cases, the preoperative localisation procedure facilitated identification and resection of the masses. Conclusions. In our experience, the main indications for hook-wire positioning before surgery are: marking of small lesions, localisation of lesions in anatomic areas structurally subverted by previous surgery and consequently difficult to detect, guidance for surgical sectioning in order to safeguard the noble structures dose to the lesions [it

  13. Bandwidth improvement for germanium photodetector using wire bonding technology.

    Science.gov (United States)

    Chen, Guanyu; Yu, Yu; Deng, Shupeng; Liu, Lei; Zhang, Xinliang

    2015-10-05

    We demonstrate an ultrahigh speed germanium photodetector by introducing gold wires into the discrete ground electrodes with standard wire bonding technology. To engineer the parasitic parameter, the physical dimension of the gold wire used for wire bonding is specially designed with an inductance of about 450 pH. Simulation and experimental results show that the bandwidth of the photodetector can be effectively extended from less than 30 GHz to over 60 GHz.

  14. Signals analysis of fluxgate array for wire rope defaults

    International Nuclear Information System (INIS)

    Gu Wei; Chu Jianxin

    2005-01-01

    In order to detecting the magnetic leakage fields of the wire rope defaults, a transducer made up of the fluxgate array is designed, and a series of the characteristic values of wire rope defaults signals are defined. By processing the characteristic signals, the LF or LMA of wire rope are distinguished, and the default extent is estimated. The experiment results of the new method for detecting the wire rope faults are introduced

  15. MDT WIRE TENSION MEASUREMENT USING AN ELECTROSTATIC METHOD

    CERN Document Server

    Balla, A; Esposito, B; Felici, G; Nedosekin, A; Ponzio, B; Russo, V; Spitalieri, M C

    1998-01-01

    An automated system to measure wire tension in MDT tubes is presented.The method uses electrostatic forces between wire and tube to excite mechanical oscillation around the wire harmonic resonance. A LC oscillating circuit is used to measure capacitance variation due towire oscillation. Wire tension is determined by the frequency at which the wirereaches the maximum oscillation amplitude. Both the excitation and measuring circuits are controlled by a computer.

  16. Electricity: Residential Wiring. Secondary Schools. Curriculum Guide.

    Science.gov (United States)

    Trust Territory of the Pacific Islands Dept. of Education, Saipan.

    This curriculum guide on residential wiring for secondary students is one of six developed for inservice teachers at Marianas High School in Saipan. The guide provides the rationale, description, goals, and objectives of the program; the program of studies and performance objectives by levels; samples of lesson plans for effective delivery of…

  17. Building Trades. Carpentry, Electrical Wiring, Plumbing.

    Science.gov (United States)

    Missouri Univ., Columbia. Instructional Materials Lab.

    This curriculum guide contains 21 units of self-paced, self-contained instructional materials in the complete building trades curriculum. It is divided into vocational areas of carpentry, electrical wiring, and plumbing. The purpose of the curriculum is to provide minimum skills for disadvantaged and handicapped students entering mainstream…

  18. Description of CBETA magnet tuning wire holders

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, S. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-07-19

    A non-­magnetic insert will be placed directly inside the permanent magnet blocks in every CBETA Halbach magnet in order to hold a set of iron “tuning wires”. These wires have various lengths around the perimeter of the aperture in order to cancel multipole field errors from the permanent magnet blocks.

  19. Selective deposition by hot wire ALD

    NARCIS (Netherlands)

    Kovalgin, Alexey Y.; Yang, Mengdi; Aarnink, Antonius A.I.; Wolters, Robertus A.M.

    2018-01-01

    A method for selectively depositing a metal nlm onto a substrate is disclosed. In particular, the method comprising nowing a metal precursor onto the substrate and nowing a non-metal precursor onto the substrate,while contacting the non-metal precursor with a hot wire. Specincally, a reaction

  20. Studying superconducting Nb$_{3}$Sn wire

    CERN Multimedia

    AUTHOR|(CDS)2099575

    2015-01-01

    Studying superconducting Nb$_{3}$Sn wire. From the current experience from LHC and HL-LHC we know that the performance requirements for Nb$_{3}$Sn conductor for future circular collider are challenging and should exceed that of present state-of-the-art materials.

  1. Studying superconducting Nb3Sn wire

    CERN Multimedia

    AUTHOR|(CDS)2099575

    2015-01-01

    Studying superconducting Nb3Sn wire. From the current experience from LHC and HL-LHC we know that the performance requirements for Nb3Sn conductor for future circular collider are challenging and should exceed that of present state-of-the-art materials.

  2. Niobium Titanium and Copper wire samples

    CERN Multimedia

    2009-01-01

    Two wire samples, both for carrying 13'000Amperes. I sample is copper. The other is the Niobium Titanium wiring used in the LHC magnets. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. Magnet coils are made of copper-clad niobium–titanium cables — each wire in the cable consists of 9’000 niobium–titanium filaments ten times finer than a hair. The cables carry up to 12’500 amps and must withstand enormous electromagnetic forces. At full field, the force on one metre of magnet is comparable ...

  3. Two-wire Interface for Digital Microphones

    NARCIS (Netherlands)

    Groothedde, Wouter; Klumperink, Eric A.M.; Nauta, Bram; Eschauzier, Rudolphe Gustave Hubertus; van Rijn, Nico

    2003-01-01

    A two-wire interface for a digital microphone circuit includes a power line and a ground line. The interface utilizes the ground line as a "voltage active line" to transmit both clock and data signals between the digital microphone circuit and a receiving circuit. The digital microphone circuit

  4. Two-Wire interface for digital microphones

    NARCIS (Netherlands)

    Groothedde, Wouter; Klumperink, Eric A.M.; Nauta, Bram; Eschauzier, Rudolphe Gustave Hubertus; van Rijn, Nico

    2005-01-01

    A two-wire interface for a digital microphone circuit includes a power line and a ground line. The interface utilizes the ground line as a "voltage active line" to transmit both clock and data signals between the digital microphone circuit and a receiving circuit. The digital microphone circuit

  5. Structured Wiring Systems: Bringing Sanity to Network Cabling!

    Science.gov (United States)

    Learn, Larry L., Ed.

    1995-01-01

    While most organizations, including libraries, can benefit from a structured wiring system, few likely have the expertise and resources to place, specify, and install network cabling by themselves. This article reviews common wiring plans, addresses basic concepts of structured wiring systems, and discusses the importance and benefits of such a…

  6. Modeling, simulation and parametric optimization of wire EDM ...

    African Journals Online (AJOL)

    In the present work, quadratic mathematical models have been derived to represent the process behavior of wire electrical discharge machining (WEDM) operation. Experiments have been conducted with six process parameters: discharge current, pulse duration, pulse frequency, wire speed, wire tension and dielectric flow ...

  7. Bonding of a niobium wire to a niobium thin film

    NARCIS (Netherlands)

    Jaszczuk, W.; Jaszczuk, W.; ter Brake, Hermanus J.M.; Flokstra, Jakob; Veldhuis, Dick; Stammis, R.; Rogalla, Horst

    1991-01-01

    A method for bonding a niobium wire to a niobium thin film is described. The bonds are to be used as superconducting connections between wire-wound gradiometers and thin-film coupling coils on DC SQUIDS. The method is characterized by two steps. Firstly, the hardness of the niobium wire is reduced

  8. 77 FR 28404 - Galvanized Steel Wire From China and Mexico

    Science.gov (United States)

    2012-05-14

    ...)] Galvanized Steel Wire From China and Mexico Determinations On the basis of the record \\1\\ developed in the... reason of imports from Mexico of galvanized steel wire, provided for in subheadings 7217.20.30, 7217.20... galvanized steel wire from China and Mexico were sold at LTFV within the meaning of 733(b) of the Act (19 U.S...

  9. 76 FR 29266 - Galvanized Steel Wire From China and Mexico

    Science.gov (United States)

    2011-05-20

    ...)] Galvanized Steel Wire From China and Mexico Determinations On the basis of the record \\1\\ developed in the... reason of imports from China and Mexico of galvanized steel wire, provided for in subheading 7217.20.30... subsidized imports of galvanized steel wire from China and Mexico. Accordingly, effective March 31, 2011, the...

  10. 46 CFR 111.30-19 - Buses and wiring.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Buses and wiring. 111.30-19 Section 111.30-19 Shipping... REQUIREMENTS Switchboards § 111.30-19 Buses and wiring. (a) General. Each bus must meet the requirements of... 60092-302 (clause 7) (incorporated by reference; see 46 CFR 110.10-1). (b) Wiring. Instrumentation and...

  11. Basic Wiring. Third Edition. Teacher Edition [and] Student Edition.

    Science.gov (United States)

    Kaltwasser, Stan; Flowers, Gary; Blasingame, Don; Batson, Larry; Ipock, Dan; Carroll, Charles; Friesen, Wade; Fleming, Glenn

    This publication contains both a teacher edition and a student edition of materials for a foundation course in an electrical wiring program. The course introduces basic concepts and skills that are prerequisites to residential wiring and commercial and industrial wiring courses. The contents of the materials are tied to measurable and observable…

  12. 29 CFR 1926.404 - Wiring design and protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Wiring design and protection. 1926.404 Section 1926.404... Requirements § 1926.404 Wiring design and protection. (a) Use and identification of grounded and grounding... construction sites, which are not a part of the permanent wiring of the building or structure and which are in...

  13. 46 CFR 129.340 - Cable and wiring.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cable and wiring. 129.340 Section 129.340 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.340 Cable and wiring. (a) If individual wires, rather than...

  14. 46 CFR 28.370 - Wiring methods and materials.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Wiring methods and materials. 28.370 Section 28.370... Operate With More Than 16 Individuals on Board § 28.370 Wiring methods and materials. (a) All cable and... not more than 10 percent. (c) Cable and wiring not serving equipment in a high risk fire area such as...

  15. 46 CFR 28.865 - Wiring methods and materials.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Wiring methods and materials. 28.865 Section 28.865... FISHING INDUSTRY VESSELS Aleutian Trade Act Vessels § 28.865 Wiring methods and materials. (a) All cable... terminals is not more than 10 percent. (c) Cable and wiring not serving equipment in high risk fire areas...

  16. Interpolation Algorithm for Fast Evaluation of EM Coupling between Wires

    NARCIS (Netherlands)

    Marasini, C.; Lepelaars, E.S.A.M.; Zwamborn, A.P.M.

    2009-01-01

    Efficient and accurate evaluation of the EM field radiated by a current flowing along a wire is essential to solve the electromagnetic coupling between arbitrary oriented wires. In this paper, a numerically efficient algorithm for the evaluation of coupling is presented. The currents along the wires

  17. 77 FR 1504 - Stainless Steel Wire Rod From India

    Science.gov (United States)

    2012-01-10

    ... COMMISSION Stainless Steel Wire Rod From India Determination On the basis of the record \\1\\ developed in the... antidumping duty order on stainless steel wire rod From India would be likely to lead to continuation or... contained in USITC Publication 4300 (January 2012), entitled Stainless Steel Wire Rod From India...

  18. Experimental investigation of industrial copper deformed by wire ...

    African Journals Online (AJOL)

    drawing on microstructure and physical properties of industrial copper wires. Copper wires were provided by E.N.I.CA.Biskra (Algeria). We investigated some wires with different strain levels (as received, 1.20, 2.10, and ε = 3.35).

  19. A laser-wire system for the International Linear Collider

    Indian Academy of Sciences (India)

    Laser-wire; accelerator test facility; laser; optical system; Compton; beam emittance; MOPA; fiber laser. Abstract. A new laser-wire has been installed in the extraction line of the ATF at KEK. It aims at demonstrating that laser-wires can be used to measure micrometre scale beam size. In parallel, studies have been made to ...

  20. A laser-wire system for the International Linear Collider

    Indian Academy of Sciences (India)

    ... line of the ATF at KEK. It aims at demonstrating that laser-wires can be used to measure micrometre scale beam size. In parallel, studies have been made to specify a laser suitable for the ILC laser-wires. Keywords. Laser-wire; accelerator test facility; laser; optical system; Compton; beam emittance; MOPA; fiber laser.

  1. Lunar Module Wiring Design Considerations and Failure Modes

    Science.gov (United States)

    Interbartolo, Michael

    2009-01-01

    This slide presentation reviews the considerations for the design of wiring for the Lunar Module. Included are a review of the choice of conductors and insulations, the wire splicing (i.e., crimping, and soldering), the wire connectors, and the fabrication of the wire harnesses. The problems in fabrication include the wires being the wrong length, the damage due to the sharp edges, the requried use of temproary protective covers and inadequate training. The problems in the wire harness installation include damge from sharp eges, work on adjacent harnesses, connector damage, and breaking wires. Engineering suggestions from the Apollo-era in reference to the conductors that are reviewed include: the use of plated conductors, and the use of alloys for stronger wiring. In refernce to insulation, the suggestions from Apollo era include the use of polymer tape-wrap wire insulation due to the light weight, however, other types of modern insulation might be more cost-effective. In reference to wire splices and terminal boards the suggestions from the Apollo Era include the use of crimp splices as superior to solder splices, joining multiple wire to a common point using modular plug-ins might be more reliable, but are heavier than crimp splicing. For connectors, the lessons from the Apollo era indicate that a rear environmental seal that does not require additional potting is preferred, and pins should be crimped or welded to the incoming wires and be removable from the rear of the connector.

  2. Load-deflection characteristics of superelastic nickel-titanium wires.

    NARCIS (Netherlands)

    Bartzela, T.; Senn, C.; Wichelhaus, A.

    2007-01-01

    OBJECTIVE: To determine the mechanical properties of commercially available thermodynamic wires and to classify these wires mathematically into different groups. MATERIALS AND METHODS: The samples examined were 48 nickel-titanium (NiTi) alloy orthodontic wires commercially available from five

  3. 30 CFR 77.705 - Guy wires; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Guy wires; grounding. 77.705 Section 77.705... MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Grounding § 77.705 Guy wires; grounding. Guy wires from poles supporting high-voltage transmission lines shall be...

  4. An X-ray scanner for wire chambers

    Science.gov (United States)

    Akesson, T.; Arik, E.; Assamagan, K.; Baker, K.; Benjamin, D.; Bertelsen, H.; Bytchkov, V.; Callahan, J.; Capeans-Garrido, M.; Catinaccio, A.; Cetin, A.; Cwetanski, P.; Danielsson, H.; Dittus, F.; Dolgoshein, B.; Dressnandt, N.; Ebenstein, W. L.; Eerola, P.; Farthouat, P.; Froidevaux, D.; Grichkevitch, Y.; Hajduk, Z.; Hansen, J. R.; Keener, P. K.; Kekelidze, G.; Konovalov, S.; Kowalski, T.; Kramarenko, V. A.; Kruger, K.; Lundberg, B.; Luehring, F.; Manara, A.; McFarlane, K.; Mitsou, V. A.; Morozov, S.; Muraviev, S.; Nadtochy, A.; Newcomer, F. M.; Olszowska, J.; Ogren, H.; Oh, S. H.; Peshekhonov, V.; Price, M.; Rembser, C.; Romaniouk, A.; Rust, D. R.; Schegelsky, V.; Sapinski, M.; Shmeleva, A.; Smirnov, S.; Smirnova, L. N.; Sosnovtsev, V.; Soutchkov, S.; Spiridenkov, E.; Tikhomirov, V.; VanBerg, R.; Vassilakopoulos, V.; Wang, C.; Williams, H. H.

    2003-07-01

    The techniques to measure the position of sense wires and field wires, the gas gain and the gas flow rate inside wire chambers using a collimated and filtered X-ray beam are reported. Specific examples are given using barrel modules of the Transition Radiation Tracker of the ATLAS experiment.

  5. Electronic conductance of quantum wire with serial periodic potential structures

    International Nuclear Information System (INIS)

    Fayad, Hisham M.; Shabat, Mohammed M.; Abdus Salam International Centre for Theoretical Physics, Trieste

    2000-08-01

    A theory based on the total transfer matrix is presented to investigate the electronic conductance in a quantum wire with serial periodic potentials. We apply the formalism in computation of the electronic conductance in a wire with different physical parameters of the wire structure. The numerical results could be used in designing some future quantum electronic devices. (author)

  6. The effect of core training on distal limb performance during ballistic strike manoeuvres.

    Science.gov (United States)

    Lee, Benjamin; McGill, Stuart

    2017-09-01

    Ballistic limb motion is enabled by proximal "core" stiffness. However, controversy exists regarding the best method of training this characteristic. This study sought to determine the most effective core training method to enhance distal limb athleticism. A total of 12 participants (24 ± 3 years, 1.8 ± 0.05 m, 76.8 ± 9.7 kg) consisting of Muay Thai athletes performed a core training protocol (Isometric vs. Dynamic, with Control) for 6 weeks, using a repeated measures design to assess performance (peak strike velocity, peak impact force, muscular activation) in various strikes. Isometric training increased impact force in Jab (554.4 ± 70.1 N), Cross (1895.2 ± 203.1 N), Combo (616.8 ± 54.9 N), and Knee (1240.0 ± 89.1 N) trials (P < 0.05). Dynamic training increased strike velocity in Jab (1.3 ± 0.2 m · s -1 ), Cross (5.5 ± 0.9 m · s -1 ), Combo (0.7 ± 0.1, 2.8 ± 0.3 m · s -1 ), and Knee (3.2 ± 0.3 m · s -1 ) trials (P < 0.05). Isometric training increased Combo impact force 935.1 ± 100.3 N greater than Dynamic and 931.6 ± 108.5 N more than Control (P < 0.05). Dynamic training increased Jab strike velocity 1.3 ± 0.1 m · s -1 greater than Isometric and 0.8 ± 0.1 m · s -1 more than Control (P < 0.05). It appears that both static and dynamic approaches to core training are needed to enhance both velocity and force in distal limbs.

  7. Low cycle fatigue life improvement of AISI 304 by initial and intermittent wire brush hammering

    OpenAIRE

    MAKHLOUF, Kamel; SIDHOM, Naziha; KHLIFI, Ammar; SIDHOM, Habib; BRAHAM, Chedly

    2013-01-01

    The effects of hammering by wire brush as a method of improving low cycle fatigue life of highly ductile austenitic stainless steel AISI 304 have been investigated through an experimental study combining imposed strain fatigue tests and assessment of surface characteristic changes under cyclic loading by SEM examinations and XRD analysis. It has been shown that the fatigue life of wire brush hammered surface was increased by 307% at an imposed strain rate of 0.2% and only 17% at an imposed st...

  8. Embedded resistance wire as a heating element for temperature control in microbioreactors

    DEFF Research Database (Denmark)

    Zainal Alam, Muhd Nazrul Hisham; Schäpper, Daniel; Gernaey, Krist

    2010-01-01

    This paper presents the technical realization of a low-cost heating element consisting of a resistance wire in a microbioreactor, as well as the implementation and performance assessment of an on/off controller for temperature control of the microbioreactor content based on this heating element...... surround the reactor chamber or are placed underneath it. The latter can achieve an even temperature distribution across the reactor chamber and direct heating of the reactor content. We show that an integrated resistance wire coupled to a simple on/off controller results in accurate temperature control...... temperature control in a batch Saccharomyces cerevisiae cultivation in a microbioreactor....

  9. Cancellous screw with tension band wiring for fractures of the olecranon.

    Science.gov (United States)

    S M, Raju; Gaddagi, Rashmi A

    2013-02-01

    Olecranon fractures are one of the most commonly seen orthopaedic injuries in the emergency room. The K-wire which is used in the AO Tension Band Wiring (TBW) technique resists the shear better than the figure of eight wire alone, but, it does not add compression to the fixation strength. But, the cancellous screw plus the tension band wire, in combination, provides the strength of fixation i.e., by converting the tensile force to a compressive force at the fracture site, with additional resistance to the displacement due to the lag screw compression. To clinically evaluate the result of the cancellous screw with tension band wiring for fractures of the olecranon.To assess the elbow joint motion and stability after the procedure. Tweenty five cases of fractures of the olecranon which were treated by using 6.5mm AO cancellous screws with a screw length of 80-105mm with a 16 gauge TBW, were evaluated . All the cases were followed up and the results were analyzed by using a 19 point scale. The results which were obtained in our series were excellent in 15(60%) patients, good in 3(12%) patients and fair in 7(28%) patients and there were no poor results. The technique of open reduction and internal fixation with a 6.5mm AO cancellous screw and TBW, is a simple and effective means of treating fractures of the olecranon and it is based on the biomechanical principle of sound.

  10. Annual coded wire tag program (Washington) missing production groups : annual report 2000; ANNUAL

    International Nuclear Information System (INIS)

    Dammers, Wolf; Mills, Robin D.

    2002-01-01

    The Bonneville Power Administration (BPA) funds the ''Annual Coded-wire Tag Program - Missing Production Groups for Columbia River Hatcheries'' project. The Washington Department of Fish and Wildlife (WDFW), Oregon Department of Fish and Wildlife (ODFW) and the United States Fish and Wildlife Service (USFWS) all operate salmon and steelhead rearing programs in the Columbia River basin. The intent of the funding is to coded-wire tag at least one production group of each species at each Columbia Basin hatchery to provide a holistic assessment of survival and catch distribution over time and to meet various measures of the Northwest Power Planning Council's (NWPPC) Fish and Wildlife Program. The WDFW project has three main objectives: (1) coded-wire tag at least one production group of each species at each Columbia Basin hatchery to enable evaluation of survival and catch distribution over time, (2) recover coded-wire tags from the snouts of fish tagged under objective 1 and estimate survival, contribution, and stray rates for each group, and (3) report the findings under objective 2 for all broods of chinook, and coho released from WDFW Columbia Basin hatcheries. Objective 1 for FY-00 was met with few modifications to the original FY-00 proposal. Under Objective 2, snouts containing coded-wire tags that were recovered during FY-00 were decoded. Under Objective 3, this report summarizes available recovery information through 2000 and includes detailed information for brood years 1989 to 1994 for chinook and 1995 to 1997 for coho

  11. Measurement of friction forces between stainless steel wires and "reduced-friction" self-ligating brackets.

    Science.gov (United States)

    Reznikov, Natalie; Har-Zion, Gilad; Barkana, Idit; Abed, Yossi; Redlich, Meir

    2010-09-01

    In this study, we assessed the friction forces between various self-ligating brackets and stainless steel orthodontic wires, subjected to different shear and bending forces in the buccolingual plane. Three kinds of self-ligating brackets and 2 kinds of ligated controls were tested in a newly developed in-vitro system. Friction was tested with stainless steel orthodontic wire in 3 deflection states. The Bonferroni multiple comparisons test was applied to evaluate intergroup differences (P friction resistance in response to wire deflection. In nonzero buccolingual deflections, passive self-ligating brackets developed higher friction forces, comparable with those in the conventional elastic ligation control group. The control brackets with reduced friction ligature had considerably lower friction forces than any other group. The active self-ligating bracket ranked between the self-ligating brackets and the reduced friction ligature group. A tribologic survey showed substantial surface alterations among wire samples coupled with passive self-ligating brackets. In contrast to manufacturers' claims, this study illustrates that, in certain clinical situations, a firm passive bracket clip can have a negative influence on the wire-bracket frictional characteristics. 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  12. Effect of tensile overloads on fatigue crack growth of high strength steel wires

    International Nuclear Information System (INIS)

    Haag, J.; Reguly, A.; Strohaecker, T.R.

    2013-01-01

    Highlights: • A proof load process may be an option to increase the fatigue life of flexible pipelines. • There is possibility to produce plastic deformation at crack tip of tensile armor wires. • Controlled overloads provide effective crack growth retardation. • Crack growth retardation is also evident at higher stress ratios. - Abstract: Fatigue of the tensile armor wires is the main failure mode of flexible risers. Techniques to increase the life of these components are required to improve the processes safety on oil exploration. This work evaluates the crack growth retardation of high strength steel wires used in flexible pipelines. Fracture toughness tests were performed to establish the level of stress intensity factor wherein the wires present significant plastic deformation at the crack tip. The effect of tensile overload on fatigue behavior was assessed by fatigue crack growth testing under constant ΔK control and different overload ratios with two different load ratios. The outcomes show that the application of controlled overloads provides crack retardation and increases the fatigue life of the wires more than 31%. This behavior is also evident at stress ratio of 0.5, in spite of the crack closure effect being minimized by increasing the applied mean stress

  13. Investigation of Shielding Properties of Yarns, Twisted with Metal Wire

    Directory of Open Access Journals (Sweden)

    Sandra VARNAITĖ-ŽURAVLIOVA

    2014-04-01

    Full Text Available The development level of the modern techniques and information technologies creates diverse nature electromagnetic fields and electric field accumulations in the human environment. Electrically conductive textiles that protect against electromagnetic waves and electric charge accumulations can be usable as protective covers for work in computer equipment rooms, measuring stands, air and gas filters and so on. One of the methods used in increase of electrical conductivity in textiles is the development of their specific structures (including the development of threads with the metal component. In this paper, unlike the currently used in the world conductive material production method, where different metal fibres are used as an additives to the main fibre composition in order to create a variety of fibres and yarns, a spun yarn with metal wire was prototyped as samples for this research and the parameters of protective properties of these samples were investigated (such as surface resistivity, vertical resistance, etc.. The protective and shielding properties of woven network with prototyped twisted electro conductive thread with a wire (metal wire diameter of 15 microns were investigated. During the investigation the influence of the following factors, such as conductive fibre composition, electrically conductive thread distribution frequency of the longitudinal and transverse direction, on the protective shielding properties of conductive network were analyzed. The research enabled the assessment of influence of electrically conductive fibre yarn composition and its distribution in the woven mesh on protective shielding properties. DOI: http://dx.doi.org/10.5755/j01.ms.20.1.2492

  14. Research regarding wires elastic deformations influence on joints positioning of a wire-driven robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-08-01

    In this paper, we present the influence of driving wires deformation on positioning precision of joints from an elephant's trunk robotic arm. Robotic arms driven by wires have the joint accuracy largely depending on wires rigidity. The joint moment of resistance causes elastic deformation of wires and it is determined by: manipulated object load, weight loads previous to the analyzed joint and inherent resistance moment of joint. Static load analysis emphasizes the particular wires elastic deformation of each driven joint from an elephant's trunk robotic arm with five degrees of freedom. We consider the case of a constant manipulated load. Errors from each driving system of joints are not part of the closed loop system. Thus, precision positioning depends on wires elastic deformation which is about microns and causes angle deviation of joints about tens of minutes of sexagesimal degrees. The closer the joints to base arm the smaller positioning precision of joint. The obtained results are necessary for further compensation made by electronic corrections in the programming algorithm of the elephant's trunk robotic arm to improve accuracy.

  15. Long-term effectiveness of canine-to-canine bonded flexible spiral wire lingual retainers

    NARCIS (Netherlands)

    Renkema, A.M.; Bronkhorst, E.M.; Katsaros, C.

    2011-01-01

    INTRODUCTION: The flexible spiral wire (FSW) canine-to-canine lingual retainer bonded to all 6 anterior teeth is a frequently used type of mandibular fixed retainer. This study aimed to assess the long-term effectiveness of FSW canine-to-canine lingual retainers in maintaining the alignment of the

  16. Long-term effectiveness of canine-to-canine bonded flexible spiral wire lingual retainers

    NARCIS (Netherlands)

    Renkema, Anne-Marie; Renkema, Alianne; Bronkhorst, Ewald; Katsaros, Christos

    Introduction: The flexible spiral wire (FSW) canine-to-canine lingual retainer bonded to all 6 anterior teeth is a frequently used type of mandibular fixed retainer. This study aimed to assess the long-term effectiveness of FSW canine-to-canine lingual retainers in maintaining the alignment of the

  17. U.S. Navy Wire-Rope Handbook. Volume 1. Design and Engineering of Wire-Rope Systems

    Science.gov (United States)

    1976-01-01

    percent nickel and are designated "Type 304 " and "Type 302" by the American Iron and Steel Institute ( AISI ). Type 304 stainless steel rope may be...from AISI Specifica- tion XYZ14 on Alloy Steel Wire) .... ............ ... 3-2 3-2. Typical Load-Elongation Behavior of Wire Rope .... ...... 3-9 3...Cosecants .......... ................... ... 10-S 10-11. Physical and Mechanical Properties of Wire ............ . .. 10-10 10-12. Wire Gauges

  18. Electrical Characterizations of Lightning Strike Protection Techniques for Composite Materials

    Science.gov (United States)

    Szatkowski, George N.; Nguyen, Truong X.; Koppen, Sandra V.; Ely, Jay J.; Mielnik, John J.

    2009-01-01

    The growing application of composite materials in commercial aircraft manufacturing has significantly increased the risk of aircraft damage from lightning strikes. Composite aircraft designs require new mitigation strategies and engineering practices to maintain the same level of safety and protection as achieved by conductive aluminum skinned aircraft. Researchers working under the NASA Aviation Safety Program s Integrated Vehicle Health Management (IVHM) Project are investigating lightning damage on composite materials to support the development of new mitigation, diagnosis & prognosis techniques to overcome the increased challenges associated with lightning protection on composite aircraft. This paper provides an overview of the electrical characterizations being performed to support IVHM lightning damage diagnosis research on composite materials at the NASA Langley Research Center.

  19. A Probabilistic, Facility-Centric Approach to Lightning Strike Location

    Science.gov (United States)

    Huddleston, Lisa L.; Roeder, William p.; Merceret, Francis J.

    2012-01-01

    A new probabilistic facility-centric approach to lightning strike location has been developed. This process uses the bivariate Gaussian distribution of probability density provided by the current lightning location error ellipse for the most likely location of a lightning stroke and integrates it to determine the probability that the stroke is inside any specified radius of any location, even if that location is not centered on or even with the location error ellipse. This technique is adapted from a method of calculating the probability of debris collisionith spacecraft. Such a technique is important in spaceport processing activities because it allows engineers to quantify the risk of induced current damage to critical electronics due to nearby lightning strokes. This technique was tested extensively and is now in use by space launch organizations at Kennedy Space Center and Cape Canaveral Air Force Station. Future applications could include forensic meteorology.

  20. Migraine strikes as neuronal excitability reaches a tipping point.

    Directory of Open Access Journals (Sweden)

    Marten Scheffer

    Full Text Available Self-propagating waves of cerebral neuronal firing, known as spreading depolarisations, are believed to be at the roots of migraine attacks. We propose that the start of spreading depolarisations corresponds to a critical transition that occurs when dynamic brain networks approach a tipping point. We show that this hypothesis is consistent with current pathogenetic insights and observed dynamics. Our view implies that migraine strikes when modulating factors further raise the neuronal excitability in genetically predisposed subjects to a level where even minor perturbations can trigger spreading depolarisations. A corollary is that recently discovered generic early warning indicators for critical transitions may be used to predict the onset of migraine attacks even before patients are clinically aware. This opens up new avenues for dissecting the mechanisms for the onset of migraine attacks and for identifying novel prophylactic treatment targets for the prevention of attacks.

  1. Precision Strike Training in Lean Manufacturing: A Workplace Literacy Guidebook [and] Final Report on Precision Strike Workplace Literacy Training at CertainTeed Corporation.

    Science.gov (United States)

    National Alliance of Business, Inc., Washington, DC.

    CertainTeed's Precision Strike training program was designed to close the gaps between the current status of its workplace and where that work force needed to be to compete successfully in global markets. Precision Strike included Skills and Knowledge in Lifelong Learning (SKILL) customized, computerized lessons in basic skills, one-on-one…

  2. The intertropical convergence zone modulates intense hurricane strikes on the western North Atlantic margin

    Science.gov (United States)

    van Hengstrum, Peter J.; Donnelly, Jeffrey P.; Fall, Patricia L.; Toomey, Michael; Albury, Nancy A.; Kakuk, Brian

    2016-01-01

    Most Atlantic hurricanes form in the Main Development Region between 9°N to 20°N along the northern edge of the Intertropical Convergence Zone (ITCZ). Previous research has suggested that meridional shifts in the ITCZ position on geologic timescales can modulate hurricane activity, but continuous and long-term storm records are needed from multiple sites to assess this hypothesis. Here we present a 3000 year record of intense hurricane strikes in the northern Bahamas (Abaco Island) based on overwash deposits in a coastal sinkhole, which indicates that the ITCZ has likely helped modulate intense hurricane strikes on the western North Atlantic margin on millennial to centennial-scales. The new reconstruction closely matches a previous reconstruction from Puerto Rico, and documents a period of elevated intense hurricane activity on the western North Atlantic margin from 2500 to 1000 years ago when paleo precipitation proxies suggest that the ITCZ occupied a more northern position. Considering that anthropogenic warming is predicted to be focused in the northern hemisphere in the coming century, these results provide a prehistoric analog that an attendant northern ITCZ shift in the future may again return the western North Atlantic margin to an active hurricane interval.

  3. Attunement to haptic information helps skilled performers select implements for striking a ball in cricket.

    Science.gov (United States)

    Headrick, Jonathon; Renshaw, Ian; Pinder, Ross A; Davids, Keith

    2012-11-01

    This study examined the perceptual attunement of relatively skilled individuals to the physical properties of striking implements in the sport of cricket. We also sought to assess whether utilizing bats with different physical properties would influence performance of a specific striking action: the front foot straight drive. Eleven skilled male cricketers (mean age = 16.6 ± 0.3 years) from an elite school cricket development program consented to participate in the study. While blindfolded, participants wielded six bats exhibiting different mass and moment of inertia (MOI) characteristics and were asked to identify the three bats they preferred the most for hitting a ball to a maximum distance by performing a front foot straight drive (a common shot in cricket). Next, participants actually attempted to hit balls projected from a ball machine using each of the six bat configurations to enable kinematic analysis of front foot straight drive performance with each implement. Results revealed that, on first choice, the two bats with the smallest mass and MOI values (1 and 2) were most preferred by almost two thirds (63.7 %) of the participants. Kinematic analysis of movement patterns revealed that bat velocity, step length, and bat-ball contact position measures significantly differed between bats. Data revealed how skilled youth cricketers were attuned to the different bat characteristics and harnessed movement system degeneracy to perform this complex interceptive action.

  4. Effects of the foot strike pattern on muscle activity and neuromuscular fatigue in downhill trail running.

    Science.gov (United States)

    Giandolini, M; Horvais, N; Rossi, J; Millet, G Y; Morin, J-B; Samozino, P

    2017-08-01

    Minimizing musculo-skeletal damage and fatigue is considered paramount for performance in trail running. Our purposes were to investigate the effects of the foot strike pattern and its variability on (a) muscle activity during a downhill trail run and (b) immediate and delayed neuromuscular fatigue. Twenty-three runners performed a 6.5-km run (1264 m of negative elevation change). Electromyographic activity of lower-limb muscles was recorded continuously. Heel and metatarsal accelerations were recorded to identify the running technique. Peripheral and central fatigue was assessed in knee extensors (KE) and plantar flexors (PF) at Pre-, Post-, and 2 days post downhill run (Post2d). Anterior patterns were associated with (a) higher gastrocnemius lateralis activity and lower tibialis anterior and vastus lateralis activity during the run and (b) larger decreases in KE high-frequency stimulus-evoked torque Post and larger decrements in KE MVC Post2d. High patterns variability during the run was associated with (a) smaller decreases in KE Db100 Post and MVC Post2d and (b) smaller decreases in PF MVC Post and Post2d. Anterior patterns increase the severity of KE peripheral fatigue. However, high foot strike pattern variability during the run reduced acute and delayed neuromuscular fatigue in KE and PF. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Striking Seasonality in the Secular Warming of the Northern Continents: Structure and Mechanisms

    Science.gov (United States)

    Nigam, S.; Thomas, N. P.

    2017-12-01

    The linear trend in twentieth-century surface air temperature (SAT)—a key secular warming signal— exhibits striking seasonal variations over Northern Hemisphere continents; SAT trends are pronounced in winter and spring but notably weaker in summer and fall. The SAT trends in historical twentieth-century climate simulations informing the Intergovernmental Panel for Climate Change's Fifth Assessment show varied (and often unrealistic) strength and structure, and markedly weaker seasonal variation. The large intra-ensemble spread of winter SAT trends in some historical simulations was surprising, especially in the context of century-long linear trends, with implications for the detection of the secular warming signal. The striking seasonality of observed secular warming over northern continents warrants an explanation and the representation of related processes in climate models. Here, the seasonality of SAT trends over North America is shown to result from land surface-hydroclimate interactions and, to an extent, also from the secular change in low-level atmospheric circulation and related thermal advection. It is argued that the winter dormancy and summer vigor of the hydrologic cycle over middle- to high-latitude continents permit different responses to the additional incident radiative energy from increasing greenhouse gas concentrations. The seasonal cycle of climate, despite its monotony, provides an expanded phase space for the exposition of the dynamical and thermodynamical processes generating secular warming, and an exceptional cost-effective opportunity for benchmarking climate projection models.

  6. Striking resilience of an island endemic bird to a severe perturbation: the case of the Gran Canaria blue chaffinch

    OpenAIRE

    Moreno, Á. C.; Carrascal, Luis M.; Delgado, A.; Suárez, V.; Seoane, J.

    2018-01-01

    [ES] Striking resilience of an island–endemic bird to a severe perturbation: the case of the Gran Canaria blue chaffinch. Evidence regarding population trends of endangered species in special protection areas and their recovery ability from catastrophic disturbances is scarce. We assessed the population trend of the Gran Canaria blue chaffinch (Fringilla polatzeki), a habitat specialist endemic to the pine forest of Inagua in the Canary Islands, following a devastating wildfire in July 2007. ...

  7. THE EFFECTS OF HEIGHT AND DISTANCE ON THE FORCE PRODUCTION AND ACCELERATION IN MARTIAL ARTS STRIKES

    Directory of Open Access Journals (Sweden)

    Cynthia A. Bir

    2009-11-01

    Full Text Available Almost all cultures have roots in some sort of self defence system and yet there is relatively little research in this area, outside of a sports related environment. This project investigated different applications of strikes from Kung Fu practitioners that have not been addressed before in the literature. Punch and palm strikes were directly compared from different heights and distances, with the use of a load cell, accelerometers, and high speed video. The data indicated that the arm accelerations of both strikes were similar, although the force and resulting acceleration of the target were significantly greater for the palm strikes. Additionally, the relative height at which the strike was delivered was also investigated. The overall conclusion is that the palm strike is a more effective strike for transferring force to an object. It can also be concluded that an attack to the chest would be ideal for maximizing impact force and moving an opponent off balance

  8. Near-field optical spectroscopy of single quantum wires

    Science.gov (United States)

    Harris, T. D.; Gershoni, D.; Grober, R. D.; Pfeiffer, L.; West, K.; Chand, N.

    1996-02-01

    Low temperature near-field scanning optical microscopy is used for spectroscopic studies of single, nanometer dimension, cleaved edge overgrown quantum wires. A direct experimental comparison between a two dimensional system and a single genuinely one dimensional quantum wire system, inaccessible to conventional far field optical spectroscopy, is enabled by the enhanced spatial resolution. We show that the photoluminescence of a single quantum wire is easily distinguished from that of the surrounding quantum well. Emission from localized centers is shown to dominate the photoluminescence from both wires and wells at low temperatures. A factor of 3 absorption enhancement for these wires compared to the wells is concluded from the photoluminescence excitation data.

  9. Laparoscopic extraction of fractured Kirschner wire from the pelvis

    Directory of Open Access Journals (Sweden)

    Vinaykumar N Thati

    2014-01-01

    Full Text Available Kirschner wire is a sharp stainless steel guide wire commonly used in fixation of fractured bone segments. There are case reports of migrated K wire from the upper limb into the spine and chest, and from the lower limb in to the abdomen and pelvis. Here, we present a case report of accidental intra-operative fracture of K wire during percutaneous femoral nailing for sub-trochanteric fracture of right femur, which migrated in to the pelvis when the orthopaedician tried to retrieve the broken segment of the K wire. This case highlights the use of laparoscopy as minimally invasive surgical option.

  10. Comparison between C1–2 Fixation with and without Supplemental Posterior Wiring

    Science.gov (United States)

    Tran, Mai; Wadhwa, Rishi; Ziewacz, John; Mummaneni, Praveen; Chou, Dean

    2014-01-01

    Study Design Retrospective analysis. Clinical Question Is there a difference between the screw–rod construct (SRC) procedure without wiring and the SRC procedure with wiring with respect to fusion, implant failure, reoperation, donor-site morbidity, and complication rates? Patients and Methods We performed a retrospective analysis of 26 patients who underwent C1–2 fixation between 2004 and 2012 (SRC with wiring and structural bone graft, 13 patients; SRC with autograft but without wiring, 13 patients). Fusion was assessed using dynamic X-rays in all patients and computed tomographic scans in selected cases. Pseudoarthrosis was confirmed during reoperation. Results The mean follow-up time was 2 years and 5 months for the SRC without wiring group and 2 years and 1 month for the SRC with wiring group. Patients with less than 1-year follow-up time were excluded. The fusion rate, implant failure rate, and reoperation rates for the SRC without wiring group were 92, 8, and 8%, respectively. The fusion, implant failure, and reoperation rates for the SRC with wiring group were 100, 0, and 0%, respectively. There were no donor-site morbidities or complications in either group (both 0%). There were no differences in parameters we examined between the two groups (p > 0.05 for each rate, Fisher exact test). Conclusions The results suggest that supplementing the SRC procedure with wiring may increase fusion rate, but this difference is not statistically significant. Although the sample size was small, there was not a significant discrepancy in outcomes between the two groups at an average follow-up of 2 years. Final class of evidence (CoE)—treatment Yes Study Design  RCT  Cohort X  Case-control  Case series Methods  Concealed allocation (RCT)  Intention to treat (RCT)  Blinded/independent evaluation of primary outcome  F/U ≥ 85%  Adequate sample size  Control for confounding Overall class of evidence III PMID:24715868

  11. Mesenteric artery contraction and relaxation studies using automated wire myography.

    Science.gov (United States)

    Bridges, Lakeesha E; Williams, Cicely L; Pointer, Mildred A; Awumey, Emmanuel M

    2011-09-22

    Proximal resistance vessels, such as the mesenteric arteries, contribute substantially to the peripheral resistance. These small vessels of between 100-400 μm in diameter function primarily in directing blood flow to various organs according to the overall requirements of the body. The rat mesenteric artery has a diameter greater than 100 μm. The myography technique, first described by Mulvay and Halpern(1), was based on the method proposed by Bevan and Osher(2). The technique provides information about small vessels under isometric conditions, where substantial shortening of the muscle preparation is prevented. Since force production and sensitivity of vessels to different agonists is dependent on the extent of stretch, according to active tension-length relation, it is essential to conduct contraction studies under isometric conditions to prevent compliance of the mounting wires. Stainless steel wires are preferred to tungsten wires because of oxidation of the latter, which affects recorded responses(3).The technique allows for the comparison of agonist-induced contractions of mounted vessels to obtain evidence for normal function of vascular smooth muscle cell receptors. We have shown in several studies that isolated mesenteric arteries that are contracted with phenylyephrine relax upon addition of cumulative concentrations of extracellular calcium (Ca(2+)(e;)). The findings led us to conclude that perivascular sensory nerves, which express the G protein-coupled Ca(2+)-sensing receptor (CaR), mediate this vasorelaxation response. Using an automated wire myography method, we show here that mesenteric arteries from Wistar, Dahl salt-sensitive(DS) and Dahl salt-resistant (DR) rats respond differently to Ca(2+)(e;). Tissues from Wistar rats showed higher Ca(2+)-sensitivity compared to those from DR and DS. Reduced CaR expression in mesenteric arteries from DS rats correlates with reduced Ca(2+)(e;)-induced relaxation of isolated, pre-contracted arteries. The data

  12. Comparison of phase boundaries between kagomé and honeycomb superconducting wire networks

    Science.gov (United States)

    Xiao, Yi; Huse, David A.; Chaikin, Paul M.; Higgins, Mark J.; Bhattacharya, Shobo; Spencer, David

    2002-06-01

    We measure resistively the mean-field superconducting-normal phase boundaries of both kagomé and honeycomb wire networks immersed in a transverse magnetic field. In addition to their agreement with theory about the overall shapes of phase diagrams, they show striking one-to-one correspondence between the cusps in the honeycomb phase boundary and those in the kagomé curve. This correspondence is due to their geometric arrangements and agrees with Lin and Nori's recent calculation. We also find that for the frustrated honeycomb network at f=1/2, the current patterns in the superconducting phase differ between the low-temperature London regime and the higher-temperature Ginzburg-Landau regime near Tc.

  13. Enhanced THz guiding properties of curved two-wire lines.

    Science.gov (United States)

    Zha, Jingshu; Kim, Geun Ju; Jeon, Tae-In

    2016-03-21

    We present experimental and simulation studies of enhanced terahertz (THz) guiding properties of curved two-wire lines for several surface conditions. When a THz-wave propagates through curved two-wire lines, a rough wire surface with dielectric coating contributes to a lower bending loss compared to a smooth or rough wire surface without coating. Dielectric coating and rough surface confine the THz field to the wire surface making the bending loss low. The guiding property at a curve depth of 30 mm of a rough wire surface with 25-μm-thick coating is improved by 34% compared to that of a smooth wire without coating. Furthermore, computer simulation technology (CST) software visually shows the bending loss as same as the experimental studies.

  14. Initial arch wires for tooth alignment during orthodontic treatment with fixed appliances.

    Science.gov (United States)

    Jian, Fan; Lai, Wenli; Furness, Susan; McIntyre, Grant T; Millett, Declan T; Hickman, Joy; Wang, Yan

    2013-04-30

    Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review 'Initial arch wires for alignment of crooked teeth with fixed orthodontic braces' first published in the Cochrane Database of Systematic Reviews 2010, Issue 4. To assess the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 2 August 2012), CENTRAL (The Cochrane Library 2012, Issue 7), MEDLINE via OVID (1950 to 2 August 2012) and EMBASE via OVID (1980 to 2 August 2012). We also searched the reference lists of relevant articles. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies. We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. Only studies involving participants with upper and/or lower full arch fixed orthodontic appliances were included. Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information. Nine RCTs with 571 participants were included in this review. All trials were at high risk of bias and a number of methodological limitations were identified. All trials had at least one

  15. Heat Transfer Analysis in Wire Bundles for Aerospace Vehicles

    Science.gov (United States)

    Rickman, S. L.; Iamello, C. J.

    2016-01-01

    Design of wiring for aerospace vehicles relies on an understanding of "ampacity" which refers to the current carrying capacity of wires, either, individually or in wire bundles. Designers rely on standards to derate allowable current flow to prevent exceedance of wire temperature limits due to resistive heat dissipation within the wires or wire bundles. These standards often add considerable margin and are based on empirical data. Commercial providers are taking an aggressive approach to wire sizing which challenges the conventional wisdom of the established standards. Thermal modelling of wire bundles may offer significant mass reduction in a system if the technique can be generalized to produce reliable temperature predictions for arbitrary bundle configurations. Thermal analysis has been applied to the problem of wire bundles wherein any or all of the wires within the bundle may carry current. Wire bundles present analytical challenges because the heat transfer path from conductors internal to the bundle is tortuous, relying on internal radiation and thermal interface conductance to move the heat from within the bundle to the external jacket where it can be carried away by convective and radiative heat transfer. The problem is further complicated by the dependence of wire electrical resistivity on temperature. Reduced heat transfer out of the bundle leads to higher conductor temperatures and, hence, increased resistive heat dissipation. Development of a generalized wire bundle thermal model is presented and compared with test data. The steady state heat balance for a single wire is derived and extended to the bundle configuration. The generalized model includes the effects of temperature varying resistance, internal radiation and thermal interface conductance, external radiation and temperature varying convective relief from the free surface. The sensitivity of the response to uncertainties in key model parameters is explored using Monte Carlo analysis.

  16. San Andreas-sized Strike-slip Fault on Europa

    Science.gov (United States)

    1998-01-01

    This mosaic of the south polar region of Jupiter's moon Europa shows the northern 290 kilometers (180 miles) of a strike-slip fault named Astypalaea Linea. The entire fault is about 810 kilometers (500 miles) long, about the size of the California portion of the San Andreas fault, which runs from the California-Mexico border north to the San Francisco Bay. In a strike-slip fault, two crustal blocks move horizontally past one another, similar to two opposing lanes of traffic. Overall motion along the fault seems to have followed a continuous narrow crack along the feature's entire length, with a path resembling steps on a staircase crossing zones that have been pulled apart. The images show that about 50 kilometers (30 miles) of displacement have taken place along the fault. The fault's opposite sides can be reconstructed like a puzzle, matching the shape of the sides and older, individual cracks and ridges broken by its movements. [figure removed for brevity, see original site] The red line marks the once active central crack of the fault. The black line outlines the fault zone, including material accumulated in the regions which have been pulled apart. Bends in the fault have allowed the surface to be pulled apart. This process created openings through which warmer, softer ice from below Europa's brittle ice shell surface, or frozen water from a possible subsurface ocean, could reach the surface. This upwelling of material formed large areas of new ice within the boundaries of the original fault. A similar pulling-apart phenomenon can be observed in the geological trough surrounding California's Salton Sea, in Death Valley and the Dead Sea. In those cases, the pulled-apart regions can include upwelled materials, but may be filled mostly by sedimentary and eroded material from above. One theory is that fault motion on Europa is induced by the pull of variable daily tides generated by Jupiter's gravitational tug on Europa. Tidal tension opens the fault and

  17. Disorder and Interaction Effects in Quantum Wires

    International Nuclear Information System (INIS)

    Smith, L W; Ritchie, D A; Farrer, I; Griffiths, J P; Jones, G A C; Thomas, K J; Pepper, M

    2012-01-01

    We present conductance measurements of quasi-one-dimensional quantum wires affected by random disorder in a GaAs/AlGaAs heterostructure. In addition to quantised conductance plateaux, we observe structure superimposed on the conductance characteristics when the channel is wide and the density is low. Magnetic field and temperature are varied to characterize the conductance features which depend on the lateral position of the 1D channel formed in a split-gate device. Our results suggest that there is enhanced backscattering in the wide channel limit, which gives rise to quantum interference effects. When the wires are free of disorder and wide, the confinement is weak so that the mutual repulsion of the electrons forces a single row to split into two. The relationship of this topological change to the disorder in the system will be discussed.

  18. Superconducting wire turns to electrical power

    CERN Document Server

    Sargent, P

    2003-01-01

    Two years after the discovery that magnesium diboride is a superconductor, engineers and entrepreneurs are keen to transform its properties into profit. The discovery of superconductivity at 39 K in the metallic compound magnesium diboride two years ago created quite a stir. Since then, physicists and chemists have come a long way in understanding the curious set of circumstances that lead to such a high critical temperature in this widely available material. At the same time, metallurgists, engineers and entrepreneurs have been focusing on the commercial potential of magnesium diboride as superconducting wire, which was the subject of a one-day meeting in Cambridge, UK, in April. Superconducting wire made from magnesium diboride could make 'second- generation' electrical machines commercially viable. (U.K.)

  19. Neutron refraction by cylindrical metal wires

    International Nuclear Information System (INIS)

    Plomp, J.; Barker, J.G.; Haan, V.O. de; Bouwman, W.G.; Well, A.A. van

    2007-01-01

    Undesired Small-Angle Neutron Scattering (SANS) from interior features of an object can be minimised by reducing the sample thickness. However, refraction effects produced by the exterior shape of the object depend upon the scattering cross-section and not on the thickness of the object. In the field of polarised neutrons a wire coil is often used to manipulate the polarisation vector of the neutron. In this paper, we show that the cylindrical shape of the wire together with the refractive index introduces an angular distribution in the neutron beam. This can be observed in instrumentation sensitive to SANS. We show results measured on three different SANS instruments: Ultra Small-Angle Neutrons Scattering (USANS), Spin-Echo Small-Angle Neutron Scattering (SESANS) and a Time-of-Flight (TOF) SESANS. These results are all in good agreement with the theory of refraction

  20. Neutron refraction by cylindrical metal wires

    Energy Technology Data Exchange (ETDEWEB)

    Plomp, J. [Faculty of Applied Sciences, Delft University of Technology, Delft (Netherlands)]. E-mail: j.plomp@tudelft.nl; Barker, J.G. [NIST Center for Neutron Research, National Institute of Standards and Technology, Gaithersburg, MD 20899 (United States); Haan, V.O. de [Faculty of Applied Sciences, Delft University of Technology, Delft (Netherlands); Bouwman, W.G. [Faculty of Applied Sciences, Delft University of Technology, Delft (Netherlands); Well, A.A. van [Faculty of Applied Sciences, Delft University of Technology, Delft (Netherlands)

    2007-05-01

    Undesired Small-Angle Neutron Scattering (SANS) from interior features of an object can be minimised by reducing the sample thickness. However, refraction effects produced by the exterior shape of the object depend upon the scattering cross-section and not on the thickness of the object. In the field of polarised neutrons a wire coil is often used to manipulate the polarisation vector of the neutron. In this paper, we show that the cylindrical shape of the wire together with the refractive index introduces an angular distribution in the neutron beam. This can be observed in instrumentation sensitive to SANS. We show results measured on three different SANS instruments: Ultra Small-Angle Neutrons Scattering (USANS), Spin-Echo Small-Angle Neutron Scattering (SESANS) and a Time-of-Flight (TOF) SESANS. These results are all in good agreement with the theory of refraction.

  1. From barbed wire to radar traps

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    Several million DM are required already to protect the building sites of power plants. From the very beginning concrete, wood, and barbed wire are used to make a protective wall against intruders, or in official German, 'unauthorized persons'. This expensive provisional set-up is later supplanted by electronic alarm and safety systems. A review of available systems helps to give a picture of power plant protection. (orig.) 891 HP [de

  2. Visible emission from exploding wire in water

    Czech Academy of Sciences Publication Activity Database

    Šimek, Milan; Prukner, Václav; Schmidt, Jiří; Koláček, Karel; Štraus, Jaroslav; Frolov, Oleksandr

    2007-01-01

    Roč. 53, č. 10 (2007), s. 53-53 ISSN 0003-0503. [The 61st Annual Gaseous Electronic Conference. Dallas, Texas , 13.10.2008-17.10.2008] R&D Projects: GA ČR GA202/06/1324 Institutional research plan: CEZ:AV0Z20430508 Keywords : Exploding wire * emission Subject RIV: BL - Plasma and Gas Discharge Physics

  3. Wire chambers with their magnetostrictive readout

    CERN Multimedia

    1974-01-01

    This set of wire chamber planes shaped as a cylinder sector was installed inside the magnet of a polarized spin target modified to allow as well momentum analysis of the produced particles. The experiment (S126) was set up by the CERN-Trieste Collaboration in the PS beam m9 to measure spin effects in the associated production of of a positive kaon and a positive Sigma by interaction of a positive pion with polarized protons.

  4. Inverter design for four-wire microgrids

    OpenAIRE

    Heredero Peris, Daniel; Pagès Giménez, Marc; Montesinos Miracle, Daniel

    2015-01-01

    This paper presents a PQ four quadrant four-wire three-phase inverter for microgrids integration. The inverter is based in two full-bridge IGBT modules connected in a three-phase configuration plus a threephase parallelized neutral branch. This topology is galvanically isolated through a single-phase transformer bank. The converter operates as a non-ideal voltage-controlled voltage source inverter under AC droop strategy with hot-swap capability based on a dynamic virtual impedance.

  5. METHOD OF MAKING WIRE FUEL ELEMENTS

    Science.gov (United States)

    Zambrow, J.L.

    1960-08-01

    A method is given for making a nuclear reactor fuel element in the form of a uranium-bearing wire clad with zirconium. A uranium bar is enclosed in a zirconium sheath which is coated with an oxide of magnesium, beryllium, or zirconium. The sheathed bar is then placed in a steel tube and reduced to the desired diameter by swaging at 800 to 900 deg C, after which the steel and oxide are removed.

  6. Effect of public transport strikes on air pollution levels in Barcelona (Spain).

    Science.gov (United States)

    Basagaña, Xavier; Triguero-Mas, Margarita; Agis, David; Pérez, Noemí; Reche, Cristina; Alastuey, Andrés; Querol, Xavier

    2018-01-01

    Public transport strikes can lead to an increase of the number of private vehicle trips, which in turn can increase air pollution levels. We aimed to estimate the change in air pollution concentrations during public transport strikes in the city of Barcelona (Spain). Data on strikes of the metro, train or bus systems were collected from government records (2005-2016). We collected daily concentrations of NOx; particulate matter with an aerodynamic diameter smaller than 10μm (PM10), 2.5μm (PM2.5), and 1μm (PM1); particle number concentration (N); black carbon (BC) and CO from research and official monitoring stations. We fitted linear regression models for each pollutant with the strike indicator as an independent variable, and models were adjusted for day of the week, month, year, and holiday periods. During the study period, there were 208days affected by a strike of the metro (28), train (106) or bus (91) systems. Half of the strikes were partial, most of them were single-day strikes, there was little overlap between strikes of the different transport systems, and all strikes had to comply with mandatory minimal services. When pooling all types of strikes, NOx and BC showed higher levels during strike days in comparison with non-strike days (increase between 4.1% and 7.7%, with higher increases for NO). The increases in these concentrations were more evident during full day and multiday metro strikes. In conclusion, alterations in public transport have consequences on air quality. This highlights the importance of public transport in reducing air pollution concentrations in cities. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Numerical Investigation of Corrugated Wire Mesh Laminate

    Directory of Open Access Journals (Sweden)

    Jeongho Choi

    2013-01-01

    Full Text Available The aim of this work is to develop a numerical model of Corrugated Wire Mesh Laminate (CWML capturing all its complexities such as nonlinear material properties, nonlinear geometry and large deformation behaviour, and frictional behaviour. Development of such a model will facilitate numerical simulation of the mechanical behaviour of the wire mesh structure under various types of loading as well as the variation of the CWML configuration parameters to tailor its mechanical properties to suit the intended application. Starting with a single strand truss model consisting of four waves with a bilinear stress-strain model to represent the plastic behaviour of stainless steel, the finite element model is gradually built up to study single-layer structures with 18 strands of corrugated wire meshes consistency and double- and quadruple-layered laminates with alternating crossply orientations. The compressive behaviour of the CWML model is simulated using contact elements to model friction and is compared to the load-deflection behaviour determined experimentally in uniaxial compression tests. The numerical model of the CWML is then employed to conduct the aim of establishing the upper and lower bounds of stiffness and load capacity achievable by such structures.

  8. Contact conductance between graphene and quantum wires

    International Nuclear Information System (INIS)

    Li Haidong; Zheng Yisong

    2009-01-01

    The contact conductance between graphene and two quantum wires which serve as the leads to connect graphene and electron reservoirs is theoretically studied. Our investigation indicates that the contact conductance depends sensitively on the graphene-lead coupling configuration. When each quantum wire couples solely to one carbon atom, the contact conductance vanishes at the Dirac point if the two carbon atoms coupling to the two leads belong to the same sublattice of graphene. We find that such a feature arises from the chirality of the Dirac electron in graphene. Such a chirality associated with conductance zero disappears when a quantum wire couples to multiple carbon atoms. The general result irrelevant to the coupling configuration is that the contact conductance decays rapidly with the increase of the distance between the two leads. In addition, in the weak graphene-lead coupling limit, when the distance between the two leads is much larger than the size of the graphene-lead contact areas and the incident electron energy is close to the Dirac point, the contact conductance is proportional to the square of the product of the two graphene-lead contact areas, and inversely proportional to the square of the distance between the two leads

  9. Results of the Fermilab wire production program

    International Nuclear Information System (INIS)

    Strauss, B.P.; Remsbottom, R.H.; Reardon, P.J.; Curtis, C.W.; McDonald, W.K.

    1976-01-01

    In examining the various schedules of wire drawing and heat treating, the Critchlow type of schedule provided the highest and most uniform data from billet to billet. It consists of a long anneal at 400 +- 20 0 C at a cold work point giving about 99 percent reduction in area from the extrusion size. Several quick copper anneals at 300 0 C may be interspersed to aid in fabrication. A final anneal at finished size both peaks up the resistivity ratio of the copper as well as the critical current of the alloy by moving dislocations to subcell walls. Using this method, critical currents of 1.7 x 10 5 A/cm 2 could be maintained in all billets. The copper cladding and sinking method looks promising and should save production costs. In spite of this, it was important to attain good packing density in the billets to assure uniform filament pattern and reduce breakage in wire drawing. Overall, a procedure was found for fabricating wire in large production lots that would be acceptable for constructing dipole magnets. It is felt that this method could be peaked up with time

  10. Reliability of the wire drawing dies

    International Nuclear Information System (INIS)

    Sheikh, A.K.; Khany, S.E.

    1993-01-01

    A wear based model is proposed for the dies used in wire drawing process. Using this wear model, it is possible to predict life of the die corresponding to a wear limit criterion. Since various quantities in the model are random in nature the resulting die life will also be random quantity characterized by an appropriate distribution. Using a probabilistic characterization of the parameters of the predictive model, Monte Carlo simulations were conducted to establish the die life distribution. To asses the sensitivity of life distribution with respect to various contributing variables (parameters), the simulation runs were conducted at different levels of these variables (parameters). It is shown that wire drawing die life is Weibull distributed. To compare the simulated results with actual time to failure, data of dies was obtained from a large wire drawing company and was compared with corresponding scenario generated by Monte Carlo simulation. Results obtained by Monte Carlo simulations were very close to the actual time to failure data. (author)

  11. NA48: Wiring up for Change

    CERN Multimedia

    2001-01-01

    The NA48 Collaboration is rebuilding its drift chambers ready for the experiment to start up again this coming July. An intricate task involving the soldering of over 24,000 wires! The future of the NA48 experiment is coming right down to the wire, that is, the wires which the Collaboration is installing in the clean room of Hall 887 on the Prévessin site. Six days a week, technicians are working in shifts to rebuild the experiment's drift chambers. The original chambers were damaged when a section of a vacuum tube imploded at the end of 1999. A year ago, CERN gave the green light for this essential part of the spectrometer to be rebuilt, so the NA48 experiment, which studies CP violation (see box), still has a bright future ahead of it. Three years of data-taking ahead The NA48 experiment aims to penetrate the secrets of CP (Charge Parity) violation. Charge and parity are two parameters which distinguish a particle from an antiparticle. In other words, an electron possesses a negative electric ...

  12. Thermosonic wire bonding of gold wire onto copper pad using the saturated interfacial phenomena

    Science.gov (United States)

    Jeng, Yeau-Ren; Aoh, Jong-Hing; Wang, Chang-Ming

    2001-12-01

    Copper has been used to replace conventional aluminium interconnection to improve the performance of deep submicron integrated circuits. This study used the saturated interfacial phenomena found in thermosonic ball bonding of gold wire onto aluminium pad to investigate thermosonic ball bonding of gold wire onto copper pad. The effects of preheat temperatures and ultrasonic powers on the bonding force were investigated by using a thermosonic bonding machine and a shear tester. This work shows that under proper preheat temperatures, the bonding force of thermosonic wire bonding can be explained based on interfacial microcontact phenomena such as energy intensity, interfacial temperature and real contact area. It is clearly shown that as the energy intensity is increased, the shear force increases, reaches a maximum, and then decreases. After saturation, i.e. the establishment of maximum atomic bonding, any type of additional energy input will damage the bonding, decreasing the shear force. If the preheat temperature is not within the proper range, the interfacial saturation phenomenon does not exist. For a preload of 0.5 N and a welding time of 15 ms in thermosonic wire bonding of gold wire onto copper pads, a maximum shear force of about 0.33 N is found where the interfacial energy intensity equals 1.8×106 J m-2 for preheat temperatures of 150°C and 170°C. Moreover, the corresponding optimal ultrasonic power is about 110 units.

  13. The Effect of Fluoridated and Non Fluoridated Mouth Washes on Color Stability of Different Aesthetic Arch Wires At Different Time Intervals (An in Vitro Study

    Directory of Open Access Journals (Sweden)

    Lubna Maky Hussein

    2018-01-01

    Full Text Available Background:The color stability of aesthetic arch wires is an important factor in the success of an aesthetic orthodontic treatment, but the color of these arch wires tends to change with time.This study was performed to assess the effect of two types of mouth washes on the color  stability of different types of aesthetic arch wires at different time intervals. Materials and methods:Four brands of nickel titanium coated aesthetic arch wires were used: epoxy coated (Orthotechnology and G&H and Teflon coated (Dany and Hubit.Thirty six samples were prepared, each sample contains ten halves of the aesthetic arch wires. They were divided into three groups according to the immersion media (distilled water as a control media, Listerine with fluoride and Listerine without fluoride and immersed for 30 seconds twice daily according to manufacturer's instructions to measure color change after 1 week, 3 weeks and 6 weeks by using spectrophotometer VITA Easyshade Compact according to Commission Internationale de l’Eclairage L*a*b* color space system. Results:It was found that there were highly significant differences in color change values of aesthetic arch wires among all immersion media at different time intervals and color change value increases as the time of immersion increases.Additionally, Listerine with fluoride mouth wash caused higher color change values of aesthetic arch wires than Listerine without fluoride and Hubit aesthetic arch wires were the least color stable while Orthotechnology aesthetic arch wires were the most color stable. Conclusions: We can conclude that the daily use of Listerine mouth washes could affect on the color stability of aesthetic arch wires. Although all tested aesthetic arch wires revealed color changes at variable degrees but some of these changes were not  visible and the others were clinically acceptable while the remaining were clinically unacceptable.

  14. Seismic fragility analysis of lap-spliced reinforced concrete columns retrofitted by SMA wire jackets

    International Nuclear Information System (INIS)

    Choi, Eunsoo; Park, Sun-Hee; Chung, Young-Soo; Kim, Hee Sun

    2013-01-01

    The aim of this study is to provide seismic fragility curves of reinforced concrete columns retrofitted by shape memory alloy wire jackets and thus assess the seismic performance of the columns against earthquakes, comparing them with reinforced concrete columns with lap-spliced and continuous reinforcement. For that purpose, this study first developed analytical models of the experimental results of the three types of columns, (1) lap-spliced reinforcement, (2) continuous reinforcement and (3) lap-spliced reinforcement and retrofitted by SMA wire jackets, using the OpenSEES program, which is oriented to nonlinear dynamic analysis. Then, a suite of ten recorded ground motions was used to conduct dynamic analyses of the analytical models with scaling of the peak ground acceleration from 0.1g to 1.0g in steps of 0.1g. From the static experimental tests, the column retrofitted with SMA wire jackets had a larger displacement ductility by a factor of 2.3 times that of the lap-spliced column, which was 6% larger compared with the ductility of the continuous reinforcement column. From the fragility analyses, the SMA wire jacketed column had median values of 0.162g and 0.567g for yield and collapse, respectively. For the yield damage state, the SMA wire jacketed column had a median value similar to the continuous reinforcement column. However, for the complete damage state, the SMA wire jacketed column showed a 1.33 times larger median value than the continuously reinforcement column. (paper)

  15. A STUDY ON THE MANAGEMENT OF DISPLACED FRACTURES OF PATELLA USING MODIFIED TENSION BAND WIRING

    Directory of Open Access Journals (Sweden)

    Hari Babu

    2015-10-01

    Full Text Available INTRODUCTION: Patella is an important component of the extensor mechanism of the knee. A patella fracture constitutes 1% of all skeletal fractures resulting from either direct or indirect trauma. Any improper and inadequate treatment would inevitably lead to a disability which would be most perceptibly felt in a country like India, where squatting is important activity in daily life. The goal of treatment is to regain the continuity of the extensor mechanism and congruity of patellofemoral a rticulation so that the normal function of the knee can be restored. Several techniques have been described for internal fixation of fractures of patella. The ideal fixation for the fracture patella is that it should be strong enough to allow early mobiliz ation, reduce posttraumatic stiffness and perhaps help the healing of the articular surface . AIMS: To analyze the functional outcome of displaced transverse fractures of the patella treated by Modified Tension Band Wiring principle (Muller using A. Dutta & S. K. Gupta Scoring System. To extend the application of Modified Tension Band wiring for minimally comminuted fractures of patella and assesses the results. CONCLUSION : The present study shows that modified tension band wiring (Muller is an effective p rocedure in the management of displaced transverse patellar fractures, with excellent to good results. Minimally comminuted patellar fractures also yielded excellent to good results with Modified tension band wiring as an extended application. The results in the present study are comparable to other modifications of Tension Band Wiring principle. The surgery of Modified Tension Band Wiring gives rigid fixation and helps in early mobilization. Regular and scheduled post- operative physiotherapy plays an impor tant role in the functional outcome.

  16. Release of nickel and chromium ions from orthodontic wires following the use of teeth whitening mouthwashes

    Directory of Open Access Journals (Sweden)

    AmirHossein Mirhashemi

    2018-02-01

    Full Text Available Abstract Background Corrosion resistance is an important requirement for orthodontic appliances. Nickel and chromium may be released from orthodontic wires and can cause allergic reactions and cytotoxicity when patients use various mouthwashes to whiten their teeth. Our study aimed to assess the release of nickel and chromium ions from nickel titanium (NiTi and stainless steel (SS orthodontic wires following the use of four common mouthwashes available on the market. Methods This in vitro, experimental study was conducted on 120 orthodontic appliances for one maxillary quadrant including five brackets, one band and half of the required length of SS, and NiTi wires. The samples were immersed in Oral B, Oral B 3D White Luxe, Listerine, and Listerine Advance White for 1, 6, 24, and 168 h. The samples immersed in distilled water served as the control group. Atomic absorption spectroscopy served to quantify the amount of released ions. Results Nickel ions were released from both wires at all time-points; the highest amount was in Listerine and the lowest in Oral B mouthwashes. The remaining two solutions were in-between this range. The process of release of chromium from the SS wire was the same as that of nickel. However, the release trend in NiTi wires was not uniform. Conclusions Listerine caused the highest release of ions. Listerine Advance White, Oral B 3D White Luxe, and distilled water were the same in terms of ion release. Oral B showed the lowest amount of ion release.

  17. Cellular nonlinear networks for strike-point localization at JET

    Science.gov (United States)

    Arena, P.; Fortuna, L.; Bruno, M.; Vagliasindi, G.; Murari, A.; Andrew, P.; Mazzitelli, G.

    2005-11-01

    At JET, the potential of fast image processing for real-time purposes is thoroughly investigated. Particular attention is devoted to smart sensors based on system on chip technology. The data of the infrared cameras were processed with a chip implementing a cellular nonlinear network (CNN) structure so as to support and complement the magnetic diagnostics in the real-time localization of the strike-point position in the divertor. The circuit consists of two layers of complementary metal-oxide semiconductor components, the first being the sensor and the second implementing the actual CNN. This innovative hardware has made it possible to determine the position of the maximum thermal load with a time resolution of the order of 30 ms. Good congruency has been found with the measurement from the thermocouples in the divertor, proving the potential of the infrared data in locating the region of the maximum thermal load. The results are also confirmed by JET magnetic codes, both those used for the equilibrium reconstructions and those devoted to the identification of the plasma boundary.

  18. Cellular nonlinear networks for strike-point localization at JET

    International Nuclear Information System (INIS)

    Arena, P.; Fortuna, L.; Bruno, M.; Vagliasindi, G.; Murari, A.; Andrew, P.; Mazzitelli, G.

    2005-01-01

    At JET, the potential of fast image processing for real-time purposes is thoroughly investigated. Particular attention is devoted to smart sensors based on system on chip technology. The data of the infrared cameras were processed with a chip implementing a cellular nonlinear network (CNN) structure so as to support and complement the magnetic diagnostics in the real-time localization of the strike-point position in the divertor. The circuit consists of two layers of complementary metal-oxide semiconductor components, the first being the sensor and the second implementing the actual CNN. This innovative hardware has made it possible to determine the position of the maximum thermal load with a time resolution of the order of 30 ms. Good congruency has been found with the measurement from the thermocouples in the divertor, proving the potential of the infrared data in locating the region of the maximum thermal load. The results are also confirmed by JET magnetic codes, both those used for the equilibrium reconstructions and those devoted to the identification of the plasma boundary

  19. Untangling the wiring of the Drosophila visual system: developmental principles and molecular strategies.

    Science.gov (United States)

    Plazaola-Sasieta, Haritz; Fernández-Pineda, Alejandra; Zhu, Qi; Morey, Marta

    2017-12-01

    The assembly of neural circuits relies on the accurate establishment of connections between synaptic partners. Precise wiring results from responses that neurons elicit to environmental cues and cell-cell contact events during development. A common design principle in both invertebrate and vertebrate adult nervous systems is the orderly array of columnar and layered synaptic units of certain neuropils. This similarity is particularly striking in the visual system, both at the structural and cell-type levels. Given the powerful genetic approaches and tools available in Drosophila, the fly visual system has been extensively used to probe how specific wiring patterns are achieved during development. In this review, we cover the developmental principles and molecular strategies that govern the assembly of columnar units (lamina cartridges and medulla columns), the formation of layers, afferent specific layer selection, and synaptogenesis in Drosophila. The mechanisms include: sequential developmental steps that ensure coordinated assembly of synaptic partners; anterograde and autocrine signaling; interactions between cell-surface molecules, or secreted molecules and their receptors that take place among neurons; and glia signaling to neurons.

  20. On the failure behaviour to striking bow penetration of impacted marine-steel structures

    Directory of Open Access Journals (Sweden)

    Prabowo Aditya Rio

    2018-04-01

    Full Text Available Demands for water transportation modes are continuously increasing as rapid economic and industrial growths in the recent decade. Ship as representative of the water transportation is generally needed to carry various products from one location to another. Besides as product carrier, ship also acts as public facility to transport human across islands for number of reasons, such as tourism and vehicle. Considering its importance, structural damage due to accidental loads or so-called impact can cause unacceptable casualties which threat ship passenger, shipping industry and maritime environment in same time. The most frequent impact phenomena occur in forms of collision and grounding, which are targeting side structure and double bottom consecutively. However, since responses of the impacts on structure are highly nonlinear and vary due to development of ship structures, sustainable analysis as an update of pioneer calculation can be beneficial as rational reference for improving safety and navigational instruments. This work aims to assess failures of the side structures subjected to penetration of striking bow in ship-ship collision scenario. Locations of impact are idealized to happen on after-end, midsection and fore-end to provide complete assessment. Striking bow is to be deployed by varying input velocity to observe significance of the fractures on the side structure. This configuration is implemented on the designed collision scenario, and later calculated using nonlinear finite element method (NLFEM. Summary of the solution indicated that the midsection produced the highest resistance against side collision. Breaching of the inner shell was successfully avoided on the fore-end, but the critical damage to the cargo was observed during bow penetration to the after-end region. This location was recommended to be added by longitudinal framing to increase its resistance against ship collision.

  1. On the failure behaviour to striking bow penetration of impacted marine-steel structures

    Science.gov (United States)

    Prabowo, Aditya Rio; Muttaqie, Teguh; Sohn, Jung Min; Bae, Dong Myung; Setiyawan, Agus

    2018-04-01

    Demands for water transportation modes are continuously increasing as rapid economic and industrial growths in the recent decade. Ship as representative of the water transportation is generally needed to carry various products from one location to another. Besides as product carrier, ship also acts as public facility to transport human across islands for number of reasons, such as tourism and vehicle. Considering its importance, structural damage due to accidental loads or so-called impact can cause unacceptable casualties which threat ship passenger, shipping industry and maritime environment in same time. The most frequent impact phenomena occur in forms of collision and grounding, which are targeting side structure and double bottom consecutively. However, since responses of the impacts on structure are highly nonlinear and vary due to development of ship structures, sustainable analysis as an update of pioneer calculation can be beneficial as rational reference for improving safety and navigational instruments. This work aims to assess failures of the side structures subjected to penetration of striking bow in ship-ship collision scenario. Locations of impact are idealized to happen on after-end, midsection and fore-end to provide complete assessment. Striking bow is to be deployed by varying input velocity to observe significance of the fractures on the side structure. This configuration is implemented on the designed collision scenario, and later calculated using nonlinear finite element method (NLFEM). Summary of the solution indicated that the midsection produced the highest resistance against side collision. Breaching of the inner shell was successfully avoided on the fore-end, but the critical damage to the cargo was observed during bow penetration to the after-end region. This location was recommended to be added by longitudinal framing to increase its resistance against ship collision.

  2. In the Hot Seat: STS-115 Lightning Strike Stand Down Debate - NASA Case Study

    Science.gov (United States)

    Kummer, Lizette; Stevens, Jennifer

    2016-01-01

    There is no way the PIC's could have seen any current' was the gist of Mike Griffin's assessment. Griffin was the NASA Administrator at the time. The buck stopped at his desk. Holding a napkin out to Pat Lampton, Griffin showed Lampton the calculations he'd made over dinner that predicted that the Pyrotechnic Initiator Controllers (PIC's) at the base of the Space Shuttle Solid Rocket Boosters (SRBs) were fine. A lightning strike the day before, the worst ever experienced with a Space Shuttle on the launch pad, caused a halt to the launch count down as technicians, engineers, and managers scrambled identify any damage to the launch system. SRB technicians and engineers assessed the data against their Lightning Strike Re-Test Requirements, determining that all but one of the requirements could be checked if they resumed the countdown. For the one remaining requirement, testing the integrity of the PIC's would require 96 hours to set up, test, and reassemble. The engineers were convinced that there was no way to do calculations to show the PIC's were okay. The only option was to stand down. It was SRB Deputy Project Manager (PM) Pat Lampton's responsibility to decide what the SRB project position needed to be to certify that their hardware was safe to fly. He had to communicate that decision to the Mission Management Team (MMT) as a Go or No Go position to resume the count down. If the answer was Go they could still meet a delayed, but acceptable launch schedule. If the answer was No Go, rescheduling the launch would be a grueling shuffling of hardware, personnel, and mission timelines to accommodate Russian missions to the Space Station, supplies for the launch, and personnel manning launch operations. On top of that, Hurricane Ernesto was spinning off the coast of Florida, threatening the need for the Shuttle to roll back to the hangar if they waited too long.

  3. Optimization of the Single Staggered Wire and Tube Heat Exchanger

    Directory of Open Access Journals (Sweden)

    Arsana I Made

    2016-01-01

    Full Text Available Wire and tube heat exchanger consists of a coiled tube, and wire is welded on the two sides of it in normal direction of the tube. Generally,wire and tube heat exchanger uses inline wire arrangement between the two sides, whereas in this study, it used staggered wire arrangement that reduces the restriction of convection heat transfer. This study performed the optimization of single staggered wire and tube heat exchanger to increase the capacity and reduce the mass of the heat exchanger. Optimization was conducted with the Hooke-Jeeves method, which aims to optimize the geometry of the heat exchanger, especially on the diameter (dw and the distance between wires (pw. The model developed to present heat transfer correlations on single staggered wire and tube heat exchanger was valid. The maximum optimization factor obtained when the diameter wire was 0.9 mm and the distance between wires (pw was 11 mm with the fref value = 1.5837. It means that the optimized design only using mass of 59,10 % and could transfer heat about 98,5 % from the basis design.

  4. Applications of surface analysis in the wire industry

    Science.gov (United States)

    Stout, David A.

    The quality of wire is judged not only by its physical properties such as tensile strength and fatigue resistance, but also by its surface finish. The surface roughness, oxide formation, cleanliness, and plating homogeneity and porosity are just a few of the surface properties than can influence the performance of a wire product. Coupled to this is the large amount of surface area generated in drawing wire. For example, a ten pound spool holds nine miles of 0.006″ diameter stainless steel wire. For these reasons surface analysis has become important both to the manufacturer and consumer of wire products. When surface analysis equipment such as AES, ESCA, and SIMS was first becoming commercially available in the late sixties and early seventies, the wire industry was beginning to enter a phase of technological development for many of its products. Wire manufacturers and users began using surface analysis to investigate such topics as adhesion of brass plated automobile tire cord to rubber and diffusion of layered deposits. Examples of surface analysis used for process control, problem solving, and project development include discoloration problems on stainless steel wire, welding problems with composite wires, diffusion formed brass coatings, and diffusion problems with solder coated and Cu plated steel wire.

  5. A new design of wire locators for drift tubes

    CERN Document Server

    Ilgner, C

    2004-01-01

    Every position-sensitive wire detector needs to solve the problem of wire positioning with a defined accuracy all over its sensitive volume. In particular, thin-walled drift tubes ("straws"), which are currently being attached to large detector units of several tens of square meters of surface, need to be equipped with wire locators along their signal wires. A wire locator has been developed together with an insertion device, especially for medium-sized drift tube systems, which significantly reduces the production time and avoids the danger of applying epoxy glue to the signal wire. The wire locator is being inserted in one single time-saving production step together with the signal wire itself. The proposed design is being compared to the rigid wire locators in use in the COMPASS straw tracking system at CERN. The investigation comprises both wire- centering capability and influence on the efficiency of adjacent detector regions, demonstrating the competitive performance of the proposed new system. Its suff...

  6. WIRELESS TENSION BAND WIRING FOR OLECRANON FRACTURES. Case Series.

    Science.gov (United States)

    Roukoz, Sami; Bayoud, Wael

    2016-01-01

    This retrospective study evaluates the results of wireless tension band wire (WTBW) which is a modified technique of tension band wires (TBW) for Mayo type II A and III A olecranon fractures. In this technique the K-wires of the TBW are replaced by a cerclage wire while keeping the figure of eight wiring. We reviewed retrospectively our WTBW cases done between 2000 and 2015 where we replaced the K-wires by a cerclage wire. In this technique no hardware migration is possible. Patients were evaluated clinically, radiographicaly and a DASH score was measured. Seventeen patients were reviewed with a mean age of 58.5 years. The mean follow-up period was 58.5 months. The mean DASH score was 12 with 7 patients having a DASH score of zero. Joint mobility was near normal compared to the other side with loss of a mean of 4º in elbow extension and a mean of 3º in elbow flexion. In comparison with other series, in addition to good results, hardware removal for medical reasons was the lowest in our technique. It was needed in three patients for pain on elbow contact and in one with ulnar nerve irritation. This represents a rate of 23.5%. Undesirable events related to the use of K-wires in standard tension band wiring, such as wire migration, wire protrusion through the skin and wire impingement, are absent in the wireless tension band wiring. The high rate of patient satisfaction, good clinical results as well as low rate of needed hardware removal make this technique preferable for fixing Mayo Type II A olecranon fractures.

  7. Body of Knowledge (BOK) for Copper Wire Bonds

    Science.gov (United States)

    Rutkowski, E.; Sampson, M. J.

    2015-01-01

    Copper wire bonds have replaced gold wire bonds in the majority of commercial semiconductor devices for the latest technology nodes. Although economics has been the driving mechanism to lower semiconductor packaging costs for a savings of about 20% by replacing gold wire bonds with copper, copper also has materials property advantages over gold. When compared to gold, copper has approximately: 25% lower electrical resistivity, 30% higher thermal conductivity, 75% higher tensile strength and 45% higher modulus of elasticity. Copper wire bonds on aluminum bond pads are also more mechanically robust over time and elevated temperature due to the slower intermetallic formation rate - approximately 1/100th that of the gold to aluminum intermetallic formation rate. However, there are significant tradeoffs with copper wire bonding - copper has twice the hardness of gold which results in a narrower bonding manufacturing process window and requires that the semiconductor companies design more mechanically rigid bonding pads to prevent cratering to both the bond pad and underlying chip structure. Furthermore, copper is significantly more prone to corrosion issues. The semiconductor packaging industry has responded to this corrosion concern by creating a palladium coated copper bonding wire, which is more corrosion resistant than pure copper bonding wire. Also, the selection of the device molding compound is critical because use of environmentally friendly green compounds can result in internal CTE (Coefficient of Thermal Expansion) mismatches with the copper wire bonds that can eventually lead to device failures during thermal cycling. Despite the difficult problems associated with the changeover to copper bonding wire, there are billions of copper wire bonded devices delivered annually to customers. It is noteworthy that Texas Instruments announced in October of 2014 that they are shipping microcircuits containing copper wire bonds for safety critical automotive applications

  8. Estimation of the Risks of Collision or Strike to Freshwater Aquatic Organisms Resulting from Operation of Instream Hydrokinetic Turbines

    Energy Technology Data Exchange (ETDEWEB)

    Schweizer, Peter E [ORNL; Cada, Glenn F [ORNL; Bevelhimer, Mark S [ORNL

    2010-05-01

    to animal populations could occur directly (e.g., from strike mortality of individuals) or indirectly (e.g., if the loss of prey species to strike reduces food for predators). Although actively swimming or passively drifting animals may collide with any of the physical structures associated with hydrokinetic devices, turbine rotors are the most likely sources for risk of strike or significant collision (DOE 2009). It is also possible that during a close encounter with a HK device no physical contact will be made between the device and the organism, either because the animal avoids the device by successfully changing its direction of movement, or by successfully evading any moving parts of the device. Oak Ridge National Laboratory (ORNL) has been funded by the US Department of Energy (DOE) Waterpower Program to evaluate strike potential and consequences for Marine and Hydrokinetic (MHK) technologies in rivers and estuaries of the United States. We will use both predictive models and laboratory/field experiments to evaluate the likelihood and consequences of strike at HK projects in rivers. Efforts undertaken at ORNL address three objectives: (1) Assess strike risk for marine and freshwater organisms; (2) Develop experimental procedures to assess the risk and consequences of strike; and (3) Conduct strike studies in experimental flumes and field installations of hydrokinetic devices. During the first year of the study ORNL collected information from the Federal Energy Regulatory Commission (FERC) MHK database about geographical distribution of proposed hydrokinetic projects (what rivers or other types of systems), HK turbine design (horizontal axis, vertical axis, other), description of proposed axial turbine (number of blades, size of blades, rotation rate, mitigation measures), and number of units per project. Where site specific information was available, we compared the location of proposed projects rotors within the channel (e.g., along cutting edge bank, middle

  9. Conventional Prompt Global Strike and Long-Range Ballistic Missiles: Background and Issues

    Science.gov (United States)

    2016-02-24

    Silver Bullet? Asking the Right Questions About Conventional Prompt Global Strike (Washington, DC: Carneige Endowment for International Peace, 2013), pp...124 James M. Acton, Silver Bullet? Asking the Right Questions About Prompt Global Strike (Washington, DC: Carnegie Endowment for International Peace, 2013), pp. 120-129. ...Conventional Prompt Global Strike and Long-Range Ballistic Missiles: Background and Issues Amy F. Woolf Specialist in Nuclear Weapons Policy

  10. Vessel Strike of Whales in Australia: The Challenges of Analysis of Historical Incident Data

    Directory of Open Access Journals (Sweden)

    David Peel

    2018-03-01

    Full Text Available Death or injury to whales from vessel strike is one of the primary threats to whale populations worldwide. However, quantifying the rate of occurrence of these collisions is difficult because many incidents are not detected (particularly from large vessels and therefore go unreported. Furthermore, varying reporting biases occur related to species identification, spatial coverage of reports and type of vessels involved. The International Whaling Commission (IWC has compiled a database of the worldwide occurrence of vessel strikes to cetaceans, within which Australia constitutes ~7% (35 reports of the reported worldwide (~471 reports vessel strike records involving large whales. Worldwide records consist largely of modern reports within the last two decades and historical evaluation of ship strike reports has mainly focused on the Northern Hemisphere. To address this we conducted a search of historical national and international print media archive databases to discover reports of vessel strikes globally, although with a focus on Australian waters. A significant number of previously unrecorded reports of vessel strikes were found for both Australia (76 and worldwide (140, resulting in a revised estimate of ~15% of global vessel strikes occurring in Australian waters. This detailed collation and analysis of vessel strike data in an Australian context has contributed to our knowledge of the worldwide occurrence of vessel strikes and challenges the notion that vessel strikes were historically rare in Australia relative to the rest of the world. The work highlights the need to examine historical records to provide context around current anthropogenic threats to marine fauna and demonstrates the importance of formalized reporting structures for effective collation of vessel strike reports. This paper examines the issues and biases in analysis of vessel strike data in general that would apply to any jurisdiction. Using the Australian data as an example

  11. Galvanic Corrosion of and Ion Release from Various Orthodontic Brackets and Wires in a Fluoride-containing Mouthwash

    Directory of Open Access Journals (Sweden)

    Soodeh Tahmasbi

    2015-09-01

    Full Text Available Background and aims. This study compared the galvanic corrosion of orthodontic wires and brackets from various man-ufacturers following exposure to a fluoride mouthwash. Materials and methods. This study was conducted on 24 lower central incisor 0.022” Roth brackets of four different commercially available brands (Dentaurum, American Orthodontics, ORJ, Shinye. These brackets along with stainless steel (SS or nickel-titanium (NiTi orthodontic wires (0.016", round were immersed in Oral-B mouthwash containing 0.05% sodium fluoride for 28 days. The electric potential (EP difference of each bracket-wire couple was measured with a Satu-rated Calomel Reference Electrode (Ag/AgCl saturated with KCl via a voltmeter. The ions released in the electrolyte weremeasured with an atomic absorption spectrometer. All the specimens were assessed under a stereomicroscope and speci-mens with corrosion were analyzed with scanning electron microscopy (SEM. Data were analyzed using ANOVA. Results. The copper ions released from specimens with NiTi wire were greater than those of samples containing SS wire. ORJ brackets released more Cu ions than other samples. The Ni ions released from Shinye brackets were significantly more than those of other specimens (P < 0.05. Corrosion rate of brackets coupled with NiTi wires was higher than that of brack-ets coupled with SS wires. Light and electron microscopic observations showed greater corrosion of ORJ brackets. Conclusion. In fluoride mouthwash, Shinye and ORJ brackets exhibited greater corrosion than Dentaurum and American Orthodontics brackets. Stainless steel brackets used with NiTi wires showed greater corrosion and thus caution is recom-mended when using them.

  12. Galvanic Corrosion of and Ion Release from Various Orthodontic Brackets and Wires in a Fluoride-containing Mouthwash.

    Science.gov (United States)

    Tahmasbi, Soodeh; Ghorbani, Mohammad; Masudrad, Mahdis

    2015-01-01

    Background and aims. This study compared the galvanic corrosion of orthodontic wires and brackets from various manufacturers following exposure to a fluoride mouthwash. Materials and methods. This study was conducted on 24 lower central incisor 0.022" Roth brackets of four different commercially available brands (Dentaurum, American Orthodontics, ORJ, Shinye). These brackets along with stainless steel (SS) or nickel-titanium (NiTi) orthodontic wires (0.016", round) were immersed in Oral-B mouthwash containing 0.05% sodium fluoride for 28 days. The electric potential (EP) difference of each bracket-wire couple was measured with a Saturated Calomel Reference Electrode (Ag/AgCl saturated with KCl) via a voltmeter. The ions released in the electrolyte weremeasured with an atomic absorption spectrometer. All the specimens were assessed under a stereomicroscope and specimens with corrosion were analyzed with scanning electron microscopy (SEM). Data were analyzed using ANOVA. Results. The copper ions released from specimens with NiTi wire were greater than those of samples containing SS wire. ORJ brackets released more Cu ions than other samples. The Ni ions released from Shinye brackets were significantly more than those of other specimens (P wires was higher than that of brackets coupled with SS wires. Light and electron microscopic observations showed greater corrosion of ORJ brackets. Conclusion. In fluoride mouthwash, Shinye and ORJ brackets exhibited greater corrosion than Dentaurum and American Orthodontics brackets. Stainless steel brackets used with NiTi wires showed greater corrosion and thus caution is recommended when using them.

  13. ‘The Nairobi General Strike [1950]: from protest to insurgency’

    OpenAIRE

    Hyde, David

    2002-01-01

    The Nairobi General Strike [1950] was the culmination of Kenya’s post war strike wave and urban upheaval. An unprecedented upsurge occurred with the general strikes in Mombasa [1947] led by the African Workers Federation [A.W.F.] and in Nairobi by the East African Trades Union Congress [E.A.T.U.C.]. While this has been termed and treated as a city wide strike, there is enough evidence to suggest a movement that went some way beyond Nairobi. The extent of the cohesion and reciprocal impacts am...

  14. Operational Functions to Achieve Synergy between Special Operations and Precision Strike

    National Research Council Canada - National Science Library

    Huff, William M

    2005-01-01

    ...). The paper describes the operational functions required from the appointed operational commander and his staff to achieve synergism through the combination of special operations and precision strike...

  15. The Chinese nuclear arsenal and its second-strike capability

    International Nuclear Information System (INIS)

    Cabestan, Jean-Pierre

    2013-03-01

    It is well known that China possesses a second- strike capability, but a great deal of uncertainty persists on the subject. Over the last few years, without officially adjusting its doctrine, China has nonetheless defined its objectives. In April 2010, the People's Liberation Army Daily indicated that China needed such a capability and contended that ballistic missile submarines (SSBNs) would constitute the safest means of delivery. In the same year, the IISS estimated that the People's Liberation Army was in possession of 90 ICBMs (66 ground-based missiles and 24 SLBMs) and 400 IRBM mainly aimed at Taiwan and Japan. The Pentagon's 2012 report proposed 50-75 ICBMs and 80 -120 IRBM and MRBM. While it is established that the People's Liberation Army is developing Jin class submarines (type-094, of which there are currently two in service, which will soon rise to five) and is developing solid-propellant missiles, which could be activated more quickly, not a great deal is known about the progress of these two projects. The JL-2 (7400 km), which is mounted on SSBNs, is still being tested. In parallel, the traditional principle to which China adheres - no first use of nuclear weapons - seems to have been slightly dented. Thus, in January 2011, the Japanese press agency Kyodo (relayed by Stratfor) reported that the People's Liberation Army had lowered the threshold for use of its strategic weapons: it could henceforth envisage a preventive nuclear strike against a nuclear power that had by conventional means destroyed key strategic targets on its territory, such as a nuclear power station, a dam, or a large city, having provided prior warning to the aggressor. But what most worries the U.S. and its Asian allies, particularly the Japanese, is the quasi-total opacity of the Chinese military nuclear programme. While in April 2010, the United States and Russia signed a treaty limiting their number of strategic weapons to 1550 by 2018, China considers

  16. FiberWire is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures.

    Science.gov (United States)

    Wright, P B; Kosmopoulos, V; Coté, R E; Tayag, T J; Nana, A D

    2009-11-01

    The metal implants used to achieve fixation of displaced transverse patellar fractures are associated with implant failure, postoperative pain and a significant re-operation rate. Recent studies have examined braided suture as a possible alternative to stainless steel wire to increase patient satisfaction and decrease re-operation rates, but suture has not demonstrated clearly superior fixation strength. FiberWire is a reinforced braided polyblend suture that has demonstrated superior characteristics to the previous sutures studied and has not to our knowledge been examined as a material for tension band fixation of transverse patellar fractures. Materials testing was performed on repeated samples of No. 5 FiberWire suture and 18-gauge stainless steel wire. The strength and stiffness of each material was measured. The two materials were then used for tension band fixation on a novel transverse patellar fracture model and tested to failure by three-point bending. The constructs included a single stainless steel wire, a single-strand FiberWire tied with a sliding knot, double-strand FiberWire tied with sliding knots and double-strand FiberWire tied with a Wagoner's Hitch. The fixation strength and stiffness of the constructs were measured. Unlike stainless steel, FiberWire maintained its initial stiffness until failure. Furthermore, during three-point-bend testing, double-strand FiberWire was found to have a significantly higher failure load than stainless steel wire when the suture was tied and locked under the tension produced by a modified Wagoner's Hitch. FiberWire is a potentially superior alternative to stainless steel wire in tension band fixation of transverse patellar fractures.

  17. Positive Emotions Associated with "Counter-Strike" Game Playing.

    Science.gov (United States)

    Shin, Mirim; Heard, Rob; Suo, Chao; Chow, Chin Moi

    2012-10-01

    Digital game playing engages people for long periods of time. The pleasure offered by digital games may explain the players' consumption of this activity. Games may elicit both positive and negative emotions, which can be measured by encephalography (EEG). The EEG alpha asymmetry index (AI) is different in positive and negative emotions and so may be used to distinguish positive from negative emotions that occur during gaming. We hypothesized that the "Counter-Strike" (CS) game (Valve Software, Bellevue, WA) is pleasurable and demonstrable with a positive EEG AI. Twelve male participants ages 18-30 years underwent EEG recordings continuously during and postgame. EEG was also recorded pregame for control conditions of baseline (sitting on a chair staring at a blank wall), movement (moving fingers on the computer keyboard with a blank screen), sound (listening to the sound of the CS game with a blank screen), and screen (watching the CS game without playing). Self-ratings of emotional responses were completed at pre-, during, and postgame. A significant decrease in the EEG AI was observed under the screen condition compared with baseline, whereas an increase was observed postgame compared with the screen condition. The participants demonstrated a positive EEG AI following the "shoot" events (shoot opponents) and negative emotions after the "being shot" events. Subjective ratings of emotional response indicated happiness during and postgame, but anger and arousal were reported only during the game. The overall results are consistent with the hypothesis that predominantly positive emotional reactions are elicited from playing the CS game and concur with positive subjective ratings of happiness. Future studies may explore the relationship of game pleasure and obsessive game play.

  18. System and method for evaluating a wire conductor

    Science.gov (United States)

    Panozzo, Edward; Parish, Harold

    2013-10-22

    A method of evaluating an electrically conductive wire segment having an insulated intermediate portion and non-insulated ends includes passing the insulated portion of the wire segment through an electrically conductive brush. According to the method, an electrical potential is established on the brush by a power source. The method also includes determining a value of electrical current that is conducted through the wire segment by the brush when the potential is established on the brush. The method additionally includes comparing the value of electrical current conducted through the wire segment with a predetermined current value to thereby evaluate the wire segment. A system for evaluating an electrically conductive wire segment is also disclosed.

  19. Successful removal of an intravesical electrical wire cable.

    Science.gov (United States)

    Ahn, Hyunsoo; Son, Hwancheol

    2014-08-01

    A few previous reports have described cases wherein electrical wire cables were inserted into the male urethra and bladder. Electrical wire cables are available at home and are easy to insert. However, after they coil in the patient's bladder, they are difficult to remove. In February 2013, a 30-year-old man presented to the emergency room of SMG-SNU Boramae Medical Center with a urethral foreign body. He had inserted an electrical wire cable into his urethra for the purpose of masturbation, despite having a regular sex partner and no underlying disease. A kidney-ureter-bladder radiography showed a tangled wire in his bladder and urethra. On the next day, we tried to remove the wire cystoscopically, but this proved to be impossible because of complex coiling and the slippery surface of the wire. A Pfannenstiel incision was made to remove the foreign body. No postoperative complications were noted.

  20. Surface cleaning of metal wire by atmospheric pressure plasma

    International Nuclear Information System (INIS)

    Nakamura, T.; Buttapeng, C.; Furuya, S.; Harada, N.

    2009-01-01

    In this study, the possible application of atmospheric pressure dielectric barrier discharge plasma for the annealing of metallic wire is examined and presented. The main purpose of the current study is to examine the surface cleaning effect for a cylindrical object by atmospheric pressure plasma. The experimental setup consists of a gas tank, plasma reactor, and power supply with control panel. The gas assists in the generation of plasma. Copper wire was used as an experimental cylindrical object. This copper wire was irradiated with the plasma, and the cleaning effect was confirmed. The result showed that it is possible to remove the tarnish which exists on the copper wire surface. The experiment reveals that atmospheric pressure plasma is usable for the surface cleaning of metal wire. However, it is necessary to examine the method for preventing oxidization of the copper wire.