WorldWideScience

Sample records for wire large appliances

  1. [A retrospective study on incisor root resorption in patients treated with bracketless invisible appliance and straight wire appliance].

    Science.gov (United States)

    Wang, Guan; Yang, Lu; Zhang, Yu-Feng; Luo, San-Lian; Zheng, Ji-Wei

    2017-02-01

    To assess root resorptions in patients treated with bracketless invisible appliance and straight wire appliance using cone-beam CT (CBCT). Twenty-eight patients treated with bracketless invisible appliance (as experimental group) or straight wire appliance (as control group) were randomly selected. CBCT images were analyzed at 3 time points (pre-operation, 6 month after operation, post-operation). Root resorption was calculated using root length at 3 time points. The difference between the 2 groups was analyzed with SPSS16.0 software package. To those teeth with no root length reduction, the bone defect was evaluated using CBCT. After 6-month of treatment, 47.3% teeth from the experimental group had root resorption, while 68.3% in the control group. There was significant difference between the 2 groups (Porthodontic treatment, the incidence of root resorption in the control groups increased to be 85.3% and 68.3% in the experimental group (Pinvisible appliance suffer from less root resorption.

  2. Mechanical evaluation of quad-helix appliance made of low-nickel stainless steel wire.

    Science.gov (United States)

    dos Santos, Rogério Lacerda; Pithon, Matheus Melo

    2013-01-01

    The objective of this study was to test the hypothesis that there is no difference between stainless steel and low-nickel stainless steel wires as regards mechanical behavior. Force, resilience, and elastic modulus produced by Quad-helix appliances made of 0.032-inch and 0.036-inch wires were evaluated. Sixty Quad-helix appliances were made, thirty for each type of alloy, being fifteen for each wire thickness, 0.032-in and 0.036-in. All the archwires were submitted to mechanical compression test using an EMIC DL-10000 machine simulating activations of 4, 6, 9, and 12 mm. Analysis of variance (ANOVA) with multiple comparisons and Tukey's test were used (p steel alloy had force, resilience, and elastic modulus similar to those made of stainless steel alloy.

  3. Mechanical evaluation of quad-helix appliance made of low-nickel stainless steel wire

    Directory of Open Access Journals (Sweden)

    Rogério Lacerda dos Santos

    2013-06-01

    Full Text Available OBJECTIVE: The objective of this study was to test the hypothesis that there is no difference between stainless steel and low-nickel stainless steel wires as regards mechanical behavior. Force, resilience, and elastic modulus produced by Quad-helix appliances made of 0.032-inch and 0.036-inch wires were evaluated. METHODS: Sixty Quad-helix appliances were made, thirty for each type of alloy, being fifteen for each wire thickness, 0.032-in and 0.036-in. All the archwires were submitted to mechanical compression test using an EMIC DL-10000 machine simulating activations of 4, 6, 9, and 12 mm. Analysis of variance (ANOVA with multiple comparisons and Tukey's test were used (p < 0.05 to assess force, resilience, and elastic modulus. RESULTS: Statistically significant difference in the forces generated, resilience and elastic modulus were found between the 0.032-in 0.036-in thicknesses (p < 0.05. CONCLUSIONS: Appliances made of low-nickel stainless steel alloy had force, resilience, and elastic modulus similar to those made of stainless steel alloy.

  4. Initial arch wires for tooth alignment during orthodontic treatment with fixed appliances.

    Science.gov (United States)

    Jian, Fan; Lai, Wenli; Furness, Susan; McIntyre, Grant T; Millett, Declan T; Hickman, Joy; Wang, Yan

    2013-04-30

    Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review 'Initial arch wires for alignment of crooked teeth with fixed orthodontic braces' first published in the Cochrane Database of Systematic Reviews 2010, Issue 4. To assess the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 2 August 2012), CENTRAL (The Cochrane Library 2012, Issue 7), MEDLINE via OVID (1950 to 2 August 2012) and EMBASE via OVID (1980 to 2 August 2012). We also searched the reference lists of relevant articles. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies. We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. Only studies involving participants with upper and/or lower full arch fixed orthodontic appliances were included. Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information. Nine RCTs with 571 participants were included in this review. All trials were at high risk of bias and a number of methodological limitations were identified. All trials had at least one

  5. Comparison of the initial orthodontic force systems produced by a new lingual bracket system and a straight-wire appliance.

    Science.gov (United States)

    Fuck, Lars-Michael; Wiechmann, Dirk; Drescher, Dieter

    2005-09-01

    Over the last few years, lingual appliances have become an established orthodontic treatment technique. Many studies have concentrated on various esthetic aspects, on laboratory and clinical procedures, and on patient comfort and compliance. The orthodontic force systems of these appliances, however, have not yet been investigated. The aim of this study was thus to determine the forces and moments produced by a new lingual bracket system during the leveling phase of orthodontic treatment and to compare those with the corresponding force system of a labial straight-wire appliance. The intra-oral situation of ten patients undergoing orthodontic treatment was replicated in measurement casts fitted with lingual and labial brackets. Special care was taken to precisely reproduce each patient's interbracket geometry. We measured each tooth's force systems as generated by a leveling arch inserted into the lingual and labial brackets. The resulting force systems of both appliances were found to be quite similar with regard to the magnitude of most force and moment components. Only the first molars were subjected to considerably greater single forces with the lingual appliance. Tipping moments were found to be significantly smaller with the lingual technique, whereas the rotational moments were significantly smaller with the labial appliance. All in all we noted significant differences between the two techniques only in certain areas which upon closer examination were distributed over only a few tooth types. The initial force systems produced by the new lingual bracket system proved to be comparable with those delivered by a conventional straight-wire appliance. The actual levels of forces and moments, however, were found in certain cases to be too heavy with both techniques. We therefore recommend the development of leveling wires producing considerably lighter forces and moments.

  6. Analyzing price and efficiency dynamics of large appliances with the experience curve approach

    International Nuclear Information System (INIS)

    Weiss, Martin; Patel, Martin K.; Junginger, Martin; Blok, Kornelis

    2010-01-01

    Large appliances are major power consumers in households of industrialized countries. Although their energy efficiency has been increasing substantially in past decades, still additional energy efficiency potentials exist. Energy policy that aims at realizing these potentials faces, however, growing concerns about possible adverse effects on commodity prices. Here, we address these concerns by applying the experience curve approach to analyze long-term price and energy efficiency trends of three wet appliances (washing machines, laundry dryers, and dishwashers) and two cold appliances (refrigerators and freezers). We identify a robust long-term decline in both specific price and specific energy consumption of large appliances. Specific prices of wet appliances decline at learning rates (LR) of 29±8% and thereby much faster than those of cold appliances (LR of 9±4%). Our results demonstrate that technological learning leads to substantial price decline, thus indicating that the introduction of novel and initially expensive energy efficiency technologies does not necessarily imply adverse price effects in the long term. By extending the conventional experience curve approach, we find a steady decline in the specific energy consumption of wet appliances (LR of 20-35%) and cold appliances (LR of 13-17%). Our analysis suggests that energy policy might be able to bend down energy experience curves. (author)

  7. Analysis of Class II patients, successfully treated with the straight-wire and Forsus appliances, based on cervical vertebral maturation status.

    Science.gov (United States)

    Servello, David F; Fallis, Drew W; Alvetro, Lisa

    2015-01-01

    To assess skeletal and dental changes in patients successfully treated with the Forsus appliance based on cervical vertebral maturation status. Forty-seven Class II patients, successfully treated with the Forsus appliance, were divided into peak and postpeak growth groups determined immediately prior to Forsus placement. The mean (SD) ages of the peak and postpeak groups were 13.4 (1.0) and 14.1 (1.3) years, respectively. Superimpositions of initial, Forsus placement, Forsus removal, and final cephalometric radiographs were completed, allowing the measurement of changes during three treatment phases. There were no significant differences between groups during treatment phase 1 (alignment/leveling), with both groups demonstrating a worsening of the Class II molar relationship. However, during treatment phase 2 (Class II correction), patients within the peak group demonstrated significantly higher mean apical base, mandibular and molar changes, and an increased rate of change compared with those in the postpeak group. No significant differences were observed during treatment phase 3 (detail/finishing). Following an initial worsening of the Class II molar relationship as a result of straight-wire appliance effects, Forsus appliance treatment initiated during cervical vertebral maturation status (CS) 3-4 elicits more effective and efficient correction of Class II molar relationships than when initiated during CS 5-6. Data support that these effects are due mainly to maxillary skeletal and dentoalveolar restraint during a period of more rapid mandibular growth.

  8. A Wire Grid Paraboloid for Large Low Frequency Telescopes

    Science.gov (United States)

    Kuiper, Tom

    2017-05-01

    Planetary magnetic fields are usually studied remotely through their electron cyclotron maser (ECM) emission from electrons trapped in their magnetic fields. Jupiter has been well studied since the 1960's because its strong magnetic field allows emissions up to about 40 MHz to be observed. The emission from Earth and other outer planets is mostly below 1 MHz and can only be observed from space. It is reasonable to assume that most exoplanets with ECM must be observed at low frequencies from space. Even optimistic assumptions about the strength of such emission leads one to conclude that very large filled aperture telescopes, with a diameters of a kilometer or more, will be needed.This paper reports on a study of a copper wire reflector with a diameter of 1 km operating between 100 kHz and 3.75 MHz. It would require 200 kg of 0.5 mm diameter copper wire (AWG 24)) to be lifted to and deployed in space. For aluminum, the mass would be about 100 kg. By optimizing the wire spacing the mass can be reduced to 80% of a simple radial-azimuthal arrangement. A relatively flat reflector (0.6 ≤ f/D ≤ 1.0) needs to be anchored at about 5 points from center to ring along 24 radii. Station-keeping CubeSats could serve as anchors. A total of about 100-120 anchors would be needed for an f/D = 1 reflector, adding 200-300 kg. to the mass of the reflector. It would be possible to carry several such reflectors into space in a single payload.The Deep Space Network is operated by the Jet Propulsion Laboratory, California Institute of Technology, under contract to the National Aeronautics and Space Administration.

  9. Development of Lightning-Resistant Overhead Ground Wire for Large-size Transmission Lines

    Science.gov (United States)

    Taniguchi, Sakae; Nagaraki, Yoshimi; Takami, Jun; Okabe, Shigemitsu; Saito, Toshiyuki; Nagano, Koji; Goda, Yutaka

    The overhead ground wire of AC 150mm2 is applied for the large-size transmission lines. According to inspections of transmission lines, melted component wires of AC 150mm2 have been found in some parts of 500kV transmission lines and it is obvious that the damages have been caused by lightning. Hence, the authors have developed lightning-resistant overhead ground wires as well as being evaluated lightning-resistant performance of the conventional AC 150mm2. In the paper, firstly, it is reported on the lightning performance of the conventional AC 150mm2 resulting from a DC arc test which is considered the polarity of currents and injected current waveforms for summer and winter lightning. As a result, the least amount of electric charges which can melt the components of the conventional wire was 180C. Then, the paper outlines the improvement of lightning performance of the overhead ground wire. Some kinds of developed ground wires as a trial piece have been proposed and tested, and here presented the characteristics of two typical developed wires among them. One is coated with conductive ceramic on the outer components and the another is enlarged a diameter of outer components. Both types of the wires show the excellent lightning performance from the DC arc test, comparing with the conventional ground wire of AC 150mm2.

  10. Assessment of perceived orthodontic appliance attractiveness.

    Science.gov (United States)

    Ziuchkovski, James P; Fields, Henry W; Johnston, William M; Lindsey, Delwin T

    2008-04-01

    To date, no studies have been published in the literature evaluating the esthetics of orthodontic appliances. The purpose of this study was to assess appliance variables, including appliance type, brand, wire, and ligature tie, for their relative attractiveness. Demographic factors were also evaluated. Appliances were placed in an adult, and digital images were captured, standardized, and incorporated into a computer-based survey. Subjects (n = 200) rated each image for attractiveness on a visual analog scale. The attractiveness ratings were analyzed by using factorial analysis of variance with repeated measures. Post-hoc testing was done with the Tukey-Kramer test (overall a appliances), ceramic, and all self-ligating/stainless steel appliances. No differences between brands in each appliance type were found. Ratings of some ceramic appliances were significantly affected by archwire and ligature tie, depending on several demographic interactions. Orthodontic appliance attractiveness varies by the following hierarchy of appliance types: alternative > ceramic > all stainless steel/self-ligating. Wire and tie selection can affect the appearance of ceramic appliances but have no impact on stainless steel or self-ligating appliances. Certain demographic factors have variable effects on attractiveness ratings.

  11. Fibrotic encapsulation of orthodontic appliance in palate.

    Science.gov (United States)

    Muthu, Jananni; Muthanandam, Sivaramakrishnan; Umapathy, Gubernath; Kannan, Anitha Logaranjani

    2017-01-01

    Iatrogenic trauma though not serious is very common in dental practice. Orthodontic treatment can inflict such injuries as they are prolonged over a long period of time. Ill-fabricated orthodontic appliances, such as wires and brackets, or the patients' habits such as application of constant pressure over the appliance can traumatize the adjacent oral soft tissues. In rare cases, these appliances can get embedded into the mucosa and gingival tissues. This case report describes one such case of iatrogenic trauma to the palatal mucosa due to entrapment of a tongue spike appliance and its surgical management.

  12. Choosing Wood Burning Appliances

    Science.gov (United States)

    Information to assist consumers in choosing a wood burning appliance, including types of appliances, the differences between certified and non-certified appliances, and alternative wood heating options.

  13. A large free-standing wire grid for microwave variable-delay polarization modulation

    Science.gov (United States)

    Voellmer, G. M.; Bennett, C.; Chuss, D. T.; Eimer, J.; Hui, H.; Moseley, S. H.; Novak, G.; Wollack, E. J.; Zeng, L.

    2008-07-01

    One technique for mapping the polarization signature of the cosmic microwave background uses large, polarizing grids in reflection. We present the system requirements, the fabrication, assembly, and alignment procedures, and the test results for the polarizing grid component of a 50 cm clear aperture, Variable-delay Polarization Modulator (VPM). This grid is being built and tested at the Goddard Space Flight Center as part of the Polarimeter for Observing Inflationary Cosmology at the Reionization Epoch (POINCARE). For the demonstration instrument, 64 μm diameter tungsten wires are being assembled into a 200 μm pitch, free-standing wire grid with a 50 cm clear aperture, and an expected overall flatness better than 30 μm. A rectangular, aluminum stretching frame holds the wires with sufficient tension to achieve a minimum resonant frequency of 185 Hz, allowing VPM mirror translation frequencies of several Hz. A lightly loaded, flattening ring with a 50 cm inside diameter rests against the wires and brings them into accurate planarity.

  14. Modeling of Service-Drop Wires and Interior-Wiring Cables for Lightning Overvoltage Studies

    Science.gov (United States)

    Matsuura, Susumu; Noda, Taku; Nakamura, Masatoshi; Sakai, Hiroshi

    As the information society progresses, a variety of electronic appliances have come into wide use in common houses. If a lightning stroke causes faults or incorrect operations of these electronic appliances, a social economic loss is considered to be large. For this reason, the focus of lightning protection measures for distribution lines in Japan has expanded to include the low-voltage side of the distribution line in addition to the high-voltage side. In order to calculate lightning overvoltages at the low-voltage side, the surge characteristics of service-drop wires and interior-wiring cables have to be modeled accurately. First, this paper describes test results of the surge characteristics of service-drop wires and interior-wiring cables. The modal surge impedances and the propagation velocities of various service-drop wires and interior-wiring cables are obtained by the test. Based on the test results obtained, this paper proposes a modeling methodology of these wires and cables for accurate EMTP (Electro-Magnetic Transients Program) lightning overvoltage simulations. The proposed model is validated by comparing EMTP simulation results with field test results.

  15. Large Eddy Simulation of turbulent flow in wire wrapped fuel pin bundles cooled by sodium

    International Nuclear Information System (INIS)

    Saxena, Aakanksha; Cadiou, Thierry; Bieder, Ulrich; Viazzo, Stephane

    2013-06-01

    The objective of the study is to understand the thermal hydraulics in a core sub-assembly with liquid sodium as coolant by performing detailed numerical simulations. The passage for the coolant flow between the fuel rods is maintained by thin wires wrapped around the rods. The contact point between the fuel pin and the spacer wire is the region of creation of hot spots and a cyclic variation of temperature in hot spots can adversely affect the mechanical properties of the clad due to the phenomena like thermal stripping. The current status quo provides two different models to perform the numerical simulations, namely Reynolds Averaged Navier-Stokes (RANS) and Large Eddy Simulation (LES). The two models differ in the extent of modelling used to close the Navier-Stokes equations. LES is a filtered approach where the large scale of motions are explicitly resolved while the small scale motions are modelled whereas RANS is a time averaging approach where all scale of motions are modelled. Thus LES involves less modelling as compared to RANS and so the results are comparatively more accurate. An attempt has been made to use the LES model. The simulations have been performed using the code Trio-U (developed by CEA). The turbulent statistics of the flow and thermal quantities are calculated. Finally the goal is to obtain the frequency of temperature oscillations at the region of hot spots near the spacer wire. (authors)

  16. A segmented appliance for space closure followed by Invisalign and fixed appliances.

    Science.gov (United States)

    Uribe, Flavio; Cutrera, Alice; Nanda, Ravinda

    2011-01-01

    This case report describes the use of a segmented appliance for space closure prior to using Invisalign. The maxillary right canine was retracted into the extracted first premolar space with a sectional wire from the first molar to the canine with no visible brackets in the incisor region. The advantage of this technique is the ability to achieve better root and rotational control during space closure with a fixed appliance that also has limited visibility. A maxillary fixed appliance was used to refine the esthetics in the maxillary arch due to the limitations of the Invisalign appliance in achieving rotational and vertical movements.

  17. Outcome of oncoplastic breast-conserving surgery following bracketing wire localization for large breast cancer.

    Science.gov (United States)

    Malhaire, Caroline; Hequet, Delphine; Falcou, Marie-Christine; Feron, Jean-Guillaume; Tardivon, Anne; Leduey, Alexandre; Guillot, Eugénie; Mosseri, Véronique; Rouzier, Roman; Couturaud, Benoit; Reyal, Fabien

    2015-08-01

    The purpose of this study was to evaluate the outcome of breast conserving surgery comparing oncoplastic surgery (OS) and standard lumpectomy (SL) after preoperative bracketing wire localization of large neoplastic lesions. We retrospectively reviewed the medical records and the mammograms of patients operated on at the Institut Curie between May 2005 and September 2011 after bracketing wire localization under mammographic and/or sonographic guidance. 113 patients underwent surgery for a pre-operative diagnosis of DCIS (n = 80), micro-invasive carcinoma (n = 9) or invasive carcinoma (n = 24), by OS (n = 73) or SL (n = 40). In the OS group, radiological size (52 mm vs 39 mm, p breast cancer and one death unrelated to cancer occurred. Following bracketing wire localization, OS allowed the conserving management of significantly larger lesions with wider resection volumes, without significant increase in margin involvement or re-intervention rate, and equivalent rate of microcalcifications clearance compared to SL. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Some aspects of the applications of wire chambers in high energy physics experiments at large accelerators

    International Nuclear Information System (INIS)

    Turala, M.

    1982-01-01

    An application of proportional and drift chambers in four large spectrometers at the accelerators of IHEP Serpukhov and CERN Geneva is described. An operation of wire chambers at high intensities and high multiplicities of particles is discussed. The results of investigations of their efficiencies, spatial resolution (for one and two-dimensional readout) and long term stability are presented. Problems of preselection of a given class of events are discussed. The systems for preselection of defined multiplicities or a scattering angle of particles, in which proportional chambers have been used, are described and the results of their application in the real experiments are presented. (author)

  19. Condenser assembly system for an appliance

    Energy Technology Data Exchange (ETDEWEB)

    Litch, Andrew David

    2017-10-17

    An appliance includes a compact condenser assembly formed with at least two separately and independently produced wire on tube condensers. Each of the at least two wire on tube condensers has a condenser inlet and a condenser outlet. The at least two wire on tube condensers are at least substantially locked and positioned in a matingly engaged configuration forming a compact condenser assembly. The at least two wire on tube condensers are configured to be operationally connected in at least one of a parallel configuration, a series configuration, a selectable configuration, and a bypass configuration.

  20. Study of a large wire chamber; Etude d`une chambre de grande taille a un fil

    Energy Technology Data Exchange (ETDEWEB)

    Marchand, C.; Del Moral, R. [Centre d`Etudes Nucleaires, Bordeaux-1 Univ., 33 Gradignan (France); Dufour, J-P. [URA451 Gradignan (France)

    1997-06-01

    We have tested a cylindrical large size single-wire chamber to check the possibility of obtaining high precision in the measurement with such detectors of the energy of the particles, dissipated entirely in the gas of the chamber. Such tests were carried out at the same time as preliminary studies of the multiwire systems devoted to measurements of individual energies, multiplicity and angular distributions for particle nuclei, with or without beta emission. The length of the chamber is 1 m, the diameter, 0.2 m and the wire diameter is 100 {mu}m. The composition of the chamber gas is 90% Ar and 10% CH{sub 4}. Several measurements were performed with this chamber and the energy spectrum from a 3 {alpha} source is given. The FWHM at 5.16 MeV is 76 keV which is a rather good value for a detector of 4 {mu}{pi} geometrical efficiency. On the basis of these results the project of a 8 wire detector was developed. The simulation of the operation of this chamber was made with the help of GARFIELD code of CERN. It was found that the field in the vicinity of the wire is very homogeneous. The paper presents also the equipotentials at 1 mm distance from the wire center. Also, are shown the gain fluctuations computed for 20 avalanches when the external tube potential and the potential center wire are matched in order to obtain a homogeneous field around the wires

  1. Influence of Wiring Cost on the Large-Scale Architecture of Human Cortical Connectivity

    Science.gov (United States)

    Samu, David; Seth, Anil K.; Nowotny, Thomas

    2014-01-01

    In the past two decades some fundamental properties of cortical connectivity have been discovered: small-world structure, pronounced hierarchical and modular organisation, and strong core and rich-club structures. A common assumption when interpreting results of this kind is that the observed structural properties are present to enable the brain's function. However, the brain is also embedded into the limited space of the skull and its wiring has associated developmental and metabolic costs. These basic physical and economic aspects place separate, often conflicting, constraints on the brain's connectivity, which must be characterized in order to understand the true relationship between brain structure and function. To address this challenge, here we ask which, and to what extent, aspects of the structural organisation of the brain are conserved if we preserve specific spatial and topological properties of the brain but otherwise randomise its connectivity. We perform a comparative analysis of a connectivity map of the cortical connectome both on high- and low-resolutions utilising three different types of surrogate networks: spatially unconstrained (‘random’), connection length preserving (‘spatial’), and connection length optimised (‘reduced’) surrogates. We find that unconstrained randomisation markedly diminishes all investigated architectural properties of cortical connectivity. By contrast, spatial and reduced surrogates largely preserve most properties and, interestingly, often more so in the reduced surrogates. Specifically, our results suggest that the cortical network is less tightly integrated than its spatial constraints would allow, but more strongly segregated than its spatial constraints would necessitate. We additionally find that hierarchical organisation and rich-club structure of the cortical connectivity are largely preserved in spatial and reduced surrogates and hence may be partially attributable to cortical wiring constraints. In

  2. Home and School Technology: Wired versus Wireless.

    Science.gov (United States)

    Van Horn, Royal

    2001-01-01

    Presents results of informal research on smart homes and appliances, structured home wiring, whole-house audio/video distribution, hybrid cable, and wireless networks. Computer network wiring is tricky to install unless all-in-one jacketed cable is used. Wireless phones help installers avoid pre-wiring problems in homes and schools. (MLH)

  3. Custom Made Pressure Appliance for Presurgical Sustained ...

    African Journals Online (AJOL)

    Among the most common complications of this therapy is ulceration due to excessive pressure. A case of presurgical size reduction for a large ear keloid with a custom made pressure appliance is presented. This novel design of the appliance allows for better control over the amount and direction of the pressure applied on ...

  4. Reconstruction of a large tracheal defect using Gore-Tex and external wire stent.

    Science.gov (United States)

    Lin, Huiqing; Huang, Jie; Hu, Hao; Geng, Qing

    2013-01-01

    Reconstruction of a tracheal defect remains to be one of the biggest challenges in thoracic surgery. We present a case in which we used Gore-Tex and an external wire stent to reconstruct 7 cm of the trachea and obtained satisfactory outcomes. Gore-Tex appears to be a biocompatible, stable, and reversible material that can be safely used to reconstruct tracheal defects.

  5. Treatment of large overjet in Angle Class II: division 1 malocclusion with Andresen activators versus prefabricated functional appliances-a multicenter, randomized, controlled trial.

    Science.gov (United States)

    Čirgić, Emina; Kjellberg, Heidrun; Hansen, Ken

    2016-10-01

    The purpose of this study was to compare the clinical effectiveness in reducing large overjet between a prefabricated functional appliance (PFA) and a slightly modified Andresen activator (AA). Public Dental Service, Gothenburg, Sweden. A multicentre, prospective randomized clinical trial was conducted with patients from 12 general dental practices. One hundred and five patients with an Angle Class II, division 1 malocclusion and an overjet of ≥6mm were eligible for the study. Eight patients were excluded due to various reasons and the sample consisted thus of 97 subjects (44 girls, 53 boys) with a mean age of 10.3 years. The study was designed as intention to treat and the patients were randomly allocated by lottery to treatment with either a PFA or an AA. The PFA and AA group consisted of 57 subjects (28 girls, 29 boys) and 40 subjects (16 girls, 24 boys), respectively. Overjet, overbite, lip seal, and sagittal molar relationship were recorded before, at the end of treatment and 1-year post-treatment. Blinding was not performed. The endpoint of treatment was set to overjet ≤3mm and after this a 6 months retention period followed. No significant difference was found in overjet, overbite, sagittal relation, and lip seal between the two groups for the total observation period. The treatment of 40 (70 per cent) patients with PFA and 21 (53 per cent) with AA were considered unsuccessful mainly due to poor compliance. No cephalometric records were taken as only patient-centred clinical outcome were used as an indicator for treatment success. The criteria of reduction of overjet to as low as 3mm could have affected the success rate. No difference in effectiveness could be shown between PFAs and AAs in correcting overjet, overbite, sagittal molar relation, and lip seal. The success rate in treatment with both appliances is, however, low. This trial was registered in "FoU i Sverige" (http://www.fou.nu/is/sverige), registration number: 97131. The protocol was not

  6. American superconductor technology to help CERN to explore the mysteries of matter company's high temperature superconductor wire to be used in CERN's Large Hadron Collider

    CERN Multimedia

    2003-01-01

    American Superconductor Corporation has been selected by CERN, to provide 14,000 meters of high temperature superconductor (HTS) wire for current lead devices that will be used in CERN's Large Hadron Collider (1 page).

  7. Ubiquitous Monitoring of Electrical Household Appliances

    Science.gov (United States)

    Lloret, Jaime; Macías, Elsa; Suárez, Alvaro; Lacuesta, Raquel

    2012-01-01

    The number of appliances at home is increasing continuously, mainly because they make our lives easier. Currently, technology is integrated in all objects of our daily life. TCP/IP let us monitor our home in real time and check ubiquitously if something is happening at home. Bearing in mind this idea, we have developed a low-cost system, which can be used in any type of electrical household appliance that takes information from the appliance and posts the information to the Twitter Social network. Several sensors placed in the household appliances gather the sensed data and send them wired or wirelessly, depending on the case, using small and cheap devices to a gateway located in the home. This gateway takes decisions, based on the received data, and sends notifications to Twitter. We have developed a software application that takes the values and decides when to issue an alarm to the registered users (Twitter friends of our smart home). The performance of our system has been measured taking into account the home network (using IEEE 802.3u and IEEE 802.11g) and the data publishing in Twitter. As a result, we have generated an original product and service for any electrical household appliance, regardless of the model and manufacturer, that helps home users improve their quality of life. The paper also shows that there is no system with the same innovative features like the ones presented in this paper. PMID:23202205

  8. Correction of an adult Class II division 2 individual using fixed functional appliance: A noncompliance approach

    Directory of Open Access Journals (Sweden)

    Shrinivas Basavaraddi

    2016-01-01

    Full Text Available This case report describes the application of fixed functional appliance in the treatment of an adult female having Class II division 2 malocclusion with retroclination of upper incisors. Fixed functional appliance was used to correct the overjet after the uprighting of upper incisors. Fixed functional appliance was fitted on a rigid rectangular arch wire. Application of fixed functional appliance achieved a good Class I molar relationship along with Class I canine relationship with normal overjet and overbite. Fixed functional appliance is effective in the treatment of Class II malocclusions, even in adult patients, and can serve as an alternate choice of treatment instead of orthognathic surgery. This is a case; wherein, fixed functional appliance was successfully used to relieve deep bite and overjet that was ensued after leveling and aligning. We demonstrate that fixed functional appliance can act as a “noncompliant corrector” and use of Class II elastics can be avoided.

  9. Evolution of treatment mechanics and contemporary appliance design in orthodontics: A 40-year perspective.

    Science.gov (United States)

    McLaughlin, Richard P; Bennett, John C

    2015-06-01

    Until the early 1970s, successful treatment with the Begg technique and the Tweed edgewise technique required tedious wire bending. The introduction of Andrews' straight wire appliance changed that, and it was one of the most significant contributions in the history of orthodontics. The straight wire appliance significantly reduced the amount of wire bending and also brought along other options in treatment mechanics. Retraction of the canines with elastic chains and ligature wires became more common. Sliding mechanics in place of closing loops became the method of space closure for a significant number of clinicians. Edgewise force levels were initially used to close spaces; however, it was soon observed that lighter forces were more effective with sliding mechanics. Along with these changes, it became apparent that compensation in the appliance was needed, depending on the type of malocclusion and particularly with varying extraction sequences. Various appliance designs were developed to accommodate changes in mechanics and force levels. These modifications improved tooth positions at the end of treatment as long as the brackets were properly placed. These major changes in appliances, force levels, and treatment mechanics can be traced back to the work of Dr Lawrence Andrews and the straight wire appliances. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  10. Oral Appliances Therapy

    Science.gov (United States)

    ... is an effective treatment option for snoring and obstructive sleep apnea (OSA). A custom-fit oral sleep appliance can improve your sleep, restore your alertness and revitalize your health. Here is a guide to help you get ...

  11. Influence of orthodontic appliance-derived artifacts on 3-T MRI movies

    Directory of Open Access Journals (Sweden)

    Erika Ozawa

    2018-02-01

    Full Text Available Abstract Background Magnetic resonance imaging (MRI has been used to study configurations of speech organs in the resting state. However, MRI is sensitive to metals, and numerous types of metallic appliances, most of which have a large magnetic susceptibility, are used in orthodontic treatment and may cause severe artifacts on MRI. We have developed techniques for obtaining MRI movies of the oral region, to evaluate articulatory changes, especially movement of the tongue, palate, and teeth, pre- and post-orthodontic/orthognathic treatment. We evaluated the influence of artifacts caused by orthodontic appliances, including fixed retainers, metal brackets, and wires, on measurements in 3-T MRI movies. Methods Sixteen healthy young adults (nine males, seven females; average age, 27 years with normal occlusion were recruited. Four types of customized maxillary and mandibular plates were prepared by incorporating one of the following into the plate: (a nothing, (b a fixed canine-to-canine retainer, (c metal brackets for the anterior and molar teeth, or (d clear brackets for the anterior teeth and metal brackets for molars. A 3-T MRI movie, in segmented cine mode, was generated for each plate condition while participants pronounced a vowel-consonant-vowel syllable (/asa/. The size of the artifact due to the metallic brackets was measured. The face size and orthodontically important anatomical structures, such as the velum, the hard palate, and the laryngeal ventricle, were also measured. Results A large artifact was observed over the entire oral region around orthodontic appliances, altering regional visibility. The velopharyngeal height was measured as significantly longer in the presence of metal brackets. The maximum artifact size due to a metallic bracket was > 8 cm. Our results show that even if it is possible to obtain the measurements of palate length, nasion to sella, and nasion to basion in individuals wearing metal brackets for molars

  12. Influence of orthodontic appliance-derived artifacts on 3-T MRI movies.

    Science.gov (United States)

    Ozawa, Erika; Honda, Ei-Ichi; Parakonthun, Kulthida Nunthayanon; Ohmori, Hiroko; Shimazaki, Kazuo; Kurabayashi, Tohru; Ono, Takashi

    2018-02-19

    Magnetic resonance imaging (MRI) has been used to study configurations of speech organs in the resting state. However, MRI is sensitive to metals, and numerous types of metallic appliances, most of which have a large magnetic susceptibility, are used in orthodontic treatment and may cause severe artifacts on MRI. We have developed techniques for obtaining MRI movies of the oral region, to evaluate articulatory changes, especially movement of the tongue, palate, and teeth, pre- and post-orthodontic/orthognathic treatment. We evaluated the influence of artifacts caused by orthodontic appliances, including fixed retainers, metal brackets, and wires, on measurements in 3-T MRI movies. Sixteen healthy young adults (nine males, seven females; average age, 27 years) with normal occlusion were recruited. Four types of customized maxillary and mandibular plates were prepared by incorporating one of the following into the plate: (a) nothing, (b) a fixed canine-to-canine retainer, (c) metal brackets for the anterior and molar teeth, or (d) clear brackets for the anterior teeth and metal brackets for molars. A 3-T MRI movie, in segmented cine mode, was generated for each plate condition while participants pronounced a vowel-consonant-vowel syllable (/asa/). The size of the artifact due to the metallic brackets was measured. The face size and orthodontically important anatomical structures, such as the velum, the hard palate, and the laryngeal ventricle, were also measured. A large artifact was observed over the entire oral region around orthodontic appliances, altering regional visibility. The velopharyngeal height was measured as significantly longer in the presence of metal brackets. The maximum artifact size due to a metallic bracket was > 8 cm. Our results show that even if it is possible to obtain the measurements of palate length, nasion to sella, and nasion to basion in individuals wearing metal brackets for molars, the measurements might be affected due to the

  13. What's driving energy efficient appliance label awareness and purchase propensity?

    International Nuclear Information System (INIS)

    Mills, Bradford; Schleich, Joachim

    2010-01-01

    The EU appliance energy consumption labeling scheme is a key component of efforts to increase the diffusion of energy-efficient household appliances. In this paper, the determinants of consumer knowledge of the energy label for household appliances and the choice of class-A energy-efficient appliances are jointly estimated using data from a large survey of more than 20,000 German households. The results for five major appliances suggest that lack of knowledge of the energy label can generate considerable bias in both estimates of rates of uptake of class-A appliances and in estimates of the underlying determinants of choice of class-A appliance. Simulations of the choice to purchase a class-A appliance, given knowledge of the labeling framework, reveal that residence characteristics and, in several cases, regional electricity prices strongly increase the propensity to purchase a class-A appliance, but socio-economic characteristics have surprisingly little impact on appliance energy-class choice.

  14. Improvement of small to large grain A15 ratio in Nb3Sn PIT wires by inverted multistage heat treatments

    Science.gov (United States)

    Segal, Christopher; Tarantini, Chiara; Lee, Peter J.; Larbalestier, David C.

    2017-12-01

    The next generation of superconducting accelerator magnets for the Large Hadron Collider at CERN will require large amounts of Nb3Sn superconducting wires and the Powder-In-Tube (PIT) process, which utilizes a NbSn2-rich powder core within tubes of Nb(7.5wt%Ta) contained in a stabilizing Cu matrix, is a potential candidate. However, the critical current density, J c , is limited by the formation of a large grain (LG) A15 layer which does not contribute to transport current, but occupies 25-30% of the total A15 area. Thus it is important to understand how this layer forms, and if it can be minimized in favor of the beneficial small grain (SG) A15 morphology which carries the supercurrent. The ratio of SG/LG A15 is our metric here, where an increase signals improvement in the wires A15 morphology distribution. We have made a critical new observation that the initiation of the LG A15 formation can be controlled at a wide range of temperatures relative to the formation of the small grain (SG) A15. The LG A15 can be uniquely identified as a decomposition product of the Nb6Sn5(Cu x ), surrounded by a layer of rejected Cu, thus the LG A15 is not only of low pin density, but is not continuous grain to grain. We have found that in single stage reactions limited to 630 °C - 690 °C, the maximum SG A15 layer thickness prior to LG A15 formation is very sensitive to temperature, with a maximum around 670 °C. This result led to the design of four novel heat treatments which all included a short, high temperature stage early in the reaction, followed by a slow cooling to a more typical reaction temperature of 630 °C. We found that this heat treatment (HT) modification increased the SG A15 layer thickness while simultaneously suppressing LG A15 morphology, with no additional consumption of the diffusion barrier. In the best heat treatment the SG/LG A15 ratio improved by 30%. Unfortunately, J c values suffered slightly, however further exploration of this high temperature

  15. Mollenhauer Aligning Auxiliary for Bodily Alignment of Blocked-out Lateral Incisors in Preadjusted Edgewise Appliance Therapy

    Directory of Open Access Journals (Sweden)

    Sreekrishnan B Nair

    2014-01-01

    Conclusion: Mollenhauer aligning auxiliary can be effectively used for the bodily alignment of lingually placed lateral incisors in preadjusted edgewise appliance therapy as an alternative to torquing with rectangular wires.

  16. The influence of different types of fixed orthodontic appliance on the growth and adherence of microorganisms (in vitro study).

    Science.gov (United States)

    Saloom, Hayder F; Mohammed-Salih, Harraa S; Rasheed, Shaymaa F

    2013-02-01

    Orthodontic appliances serve as different impact zones and modify microbial adherence and colonization, acting as foreign reserves and possible sources of infection. This study was conducted to investigate the effect of different types of fixed orthodontic appliances on the growth and adherence of microorganisms in oral flora which are Streptococcus mutans (S. mutans) and Candida albicans. Sixty-four of four different fixed orthodontic appliance-samples were used, divided into four groups of sixteen. Type I: Sapphire brackets- Coated wires, type II: Sapphire brackets- Stainless steel wires, type III: Stainless steel brackets- Coated wires and type IV: Stainless steel brackets- Stainless steel wires. Oral strains of S. mutans and Candida albicans were studied in the present study using biochemical test then microbial suspensions were prepared to do the tests of each microorganism including the antimicrobial effects of different appliance-samples on the growth of microorganisms and their adhesion tests. The results showed significant differences between the different appliances in terms of inhibition zone formation (PAppliance with high esthetic appearance, sapphire brackets and coated arch wire, showed the least adherence of S. mutans and Candida albicans in comparison to other appliances with less esthetic and more metal components. Key words:Orthodontic appliance, Adherence, Streptococcus mutans, Candida albicans.

  17. Basic Wiring.

    Science.gov (United States)

    Kaltwasser, Stan; And Others

    This module is the first in a series of three wiring publications; it serves as the foundation for students enrolled in a wiring program. It is a prerequisite to either "Residential Wiring" or "Commercial and Industrial Wiring." The module contains 16 instructional units that cover the following topics: occupational…

  18. Colostomies and the use of colostomy appliances.

    Science.gov (United States)

    Cronin, Elaine

    The surgical formation of a colostomy is indicated as part of the treatment of various conditions, primarily colon cancer, requiring the patient (ostomist) to wear a colostomy pouch. Today's stoma appliances bear no resemblance to those worn three or four decades ago when colostomy, ileostomy and urostomy bags were made entirely from rubber. The patient, who would have two to three bags in circulation at a time, would interchange them allowing for the washing and drying of the previous one, thus minimizing odour and potential perishing of the rubber. The design of these appliances was simple, but they were large and bulky and the outlet resembled that of a hot-water bottle stopper or a cap from an old soda bottle that required the insertion of coinage (2p) to open it. This article explores the range of colostomy appliances and management options available to the nurse when caring for patients with a colostomy.

  19. Bracket/wire play: what to expect from tipping prescription on pre-adjusted appliances Folga braquete/fio: o que esperar da prescrição para inclinação nos aparelhos pré-ajustados

    Directory of Open Access Journals (Sweden)

    Leopoldino Capelozza Filho

    2012-08-01

    Full Text Available INTRODUCTION: The opinion on the 'straight-wire' concept has been evolving since its origin, characterized by faithful followers or absolute skepticism. Currently, it seems reasonable to state that most professionals have a more realistic and critical viewpoint, with an attitude that reveals Orthodontics' maturity and greater knowledge on the technique. The most relevant criticisms refer to the impossibility of the both the Straight-Wire and the Standard systems to completely express the characteristics related to the brackets due to mechanical deficiencies, such as bracket/wire play. OBJECTIVES: A critical analysis of this relationship, which is unclear due to lack of studies, was the scope of this paper. METHODS: The compensatory treatment of two patients, using Capelozza's individualized brackets, works as the scenery for cephalometric evaluation of changes in incisor inclination produced by different dimensions of leveling archwires. RESULTS: The evaluation of these cases showed that, while the introduction of a 0.019 x 0.025-in stainless steel archwire in a 0.022 x 0.030-in slot did not produce significant changes in incisor inclination, the 0.021 x 0.025-in archwire was capable of changing it, mainly in mandibular incisors, and in the opposite direction to the compensation. CONCLUSION: Considering compensatory treatments, even when using an individualized prescription according to the malocclusion, the bracket/wire play seems to be a positive factor for malocclusion correction, without undesirable movements. Therefore, it seems reasonable to admit that, until a bracket system can have absolute individualization, the use of rectangular wires that still have a certain play with the bracket slot is advisable.INTRODUÇÃO: a opinião sobre o conceito Straight-Wire tem evoluído desde sua origem, caracterizada por seguidores fiéis ou ceticismo absoluto. Atualmente, parece razoável acreditar que a maioria dos profissionais tem uma visão mais

  20. Custom Made Pressure Appliance for Presurgical Sustained ...

    African Journals Online (AJOL)

    of Plastic Surgery for the fabrication of ear pressure clip for the left auricular keloid. She complained of swelling ... A case of presurgical size reduction for a large ear keloid with a custom made pressure appliance is presented. ... She was also instructed about use, maintenance of hygiene and regular follow-up for periodic ...

  1. Initial arch wires for alignment of crooked teeth with fixed orthodontic braces.

    LENUS (Irish Health Repository)

    Wang, Yan

    2010-01-01

    The initial arch wire is the first arch wire to be inserted into the fixed appliance at the beginning of orthodontic treatment and is used mainly for correcting crowding and rotations of teeth. With a number of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment.

  2. Designing, Building and Controlling of Home Appliances Unit Using PC

    Directory of Open Access Journals (Sweden)

    Saleh Ben Safar

    2017-12-01

    Full Text Available Smart home is a residential building that is usually new or modern equipped with necessary tools and wiring that enable its occupants to control a number of electrical devices and several household appliances through a suitable software. Recently, the development of home automation systems is accelerating rapidly as a result of the rapid intersection of modern technologies. Here we are talking about systems for home communication networks as well as entertainment, security, convenience, etc. These systems are controlled by sending signals through wires distributed throughout the house or Through wireless means to programmable keys or devices so that they understand these commands and deal with them as desired. In this paper, I will discuss how to design the circuit with appropriate components, build it in Printed Circuit Board and connect it to a personal computer by using programmable language in order to control all home appliances by just one click. 

  3. Oral radiation protector appliance

    International Nuclear Information System (INIS)

    Persico, T.M.; Dudas, R.M.; Shusta, G.W.

    1982-01-01

    An appliance for protecting teeth, gingiva, periodontal or alveola bone, salivary glands, and adjacent body areas against the harmful side effects of radiation therapy consists of an intraoral portion and an extraoral portion that may be selectively attached. The intraoral portion is substantially u-shaped to encompass the teeth and adjacent areas. The intraoral part may be made of lead sheet coated with plastic; the extraoral portion may be of lead sheet

  4. Wisdom Appliance Control System

    Science.gov (United States)

    Hendrick; Jheng, Jyun-Teng; Tsai, Chen-Chai; Liou, Jia-Wei; Wang, Zhi-Hao; Jong, Gwo-Jia

    2017-07-01

    Intelligent appliances wisdom involves security, home care, convenient and energy saving, but the home automation system is still one of the core unit, and also using micro-processing electronics technology to centralized and control the home electrical products and systems, such as: lighting, television, fan, air conditioning, stereo, it composed of front-controller systems and back-controller panels, user using front-controller to control command, and then through the back-controller to powered the device.

  5. Vibhute Class II Correction Appliance

    Directory of Open Access Journals (Sweden)

    Pavankumar Janardan Vibhute

    2013-01-01

    Full Text Available Fixed functional appliances have gained the popularity for growth modification in noncompliant patients, especially hybrid types. But for this, clinicians have to depend on certain commercially available appliances; otherwise components required in fabrication of hybrid type appliances are not routinely available in clinics, which discourage their, use. Additionally, these preformed appliances have less scope in changing their length as per patient′s requirement of particular mandibular advancement. This article explains the chairside fabrication of open coil NiTi spring loaded hybrid type fixed functional appliance named ′Vibhute Class II Correction Appliance′ (VCCA. This custom-made tinier and hygienic design provides stable fixation, less breakages with increased range of mandibular movement involving unrestricted mouth opening. VCCA permits quick chairside fabrication with ease in installation of appliance and is inexpensive.

  6. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  7. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  8. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  9. Incorporating experience curves in appliance standards analysis

    International Nuclear Information System (INIS)

    Desroches, Louis-Benoit; Garbesi, Karina; Kantner, Colleen; Van Buskirk, Robert; Yang, Hung-Chia

    2013-01-01

    There exists considerable evidence that manufacturing costs and consumer prices of residential appliances have decreased in real terms over the last several decades. This phenomenon is generally attributable to manufacturing efficiency gained with cumulative experience producing a certain good, and is modeled by an empirical experience curve. The technical analyses conducted in support of U.S. energy conservation standards for residential appliances and commercial equipment have, until recently, assumed that manufacturing costs and retail prices remain constant during the projected 30-year analysis period. This assumption does not reflect real market price dynamics. Using price data from the Bureau of Labor Statistics, we present U.S. experience curves for room air conditioners, clothes dryers, central air conditioners, furnaces, and refrigerators and freezers. These experience curves were incorporated into recent energy conservation standards analyses for these products. Including experience curves increases the national consumer net present value of potential standard levels. In some cases a potential standard level exhibits a net benefit when considering experience, whereas without experience it exhibits a net cost. These results highlight the importance of modeling more representative market prices. - Highlights: ► Past appliance standards analyses have assumed constant equipment prices. ► There is considerable evidence of consistent real price declines. ► We incorporate experience curves for several large appliances into the analysis. ► The revised analyses demonstrate larger net present values of potential standards. ► The results imply that past standards analyses may have undervalued benefits.

  10. Wire Array Photovoltaics

    Science.gov (United States)

    Turner-Evans, Dan

    Over the past five years, the cost of solar panels has dropped drastically and, in concert, the number of installed modules has risen exponentially. However, solar electricity is still more than twice as expensive as electricity from a natural gas plant. Fortunately, wire array solar cells have emerged as a promising technology for further lowering the cost of solar. Si wire array solar cells are formed with a unique, low cost growth method and use 100 times less material than conventional Si cells. The wires can be embedded in a transparent, flexible polymer to create a free-standing array that can be rolled up for easy installation in a variety of form factors. Furthermore, by incorporating multijunctions into the wire morphology, higher efficiencies can be achieved while taking advantage of the unique defect relaxation pathways afforded by the 3D wire geometry. The work in this thesis shepherded Si wires from undoped arrays to flexible, functional large area devices and laid the groundwork for multijunction wire array cells. Fabrication techniques were developed to turn intrinsic Si wires into full p-n junctions and the wires were passivated with a-Si:H and a-SiNx:H. Single wire devices yielded open circuit voltages of 600 mV and efficiencies of 9%. The arrays were then embedded in a polymer and contacted with a transparent, flexible, Ni nanoparticle and Ag nanowire top contact. The contact connected >99% of the wires in parallel and yielded flexible, substrate free solar cells featuring hundreds of thousands of wires. Building on the success of the Si wire arrays, GaP was epitaxially grown on the material to create heterostructures for photoelectrochemistry. These cells were limited by low absorption in the GaP due to its indirect bandgap, and poor current collection due to a diffusion length of only 80 nm. However, GaAsP on SiGe offers a superior combination of materials, and wire architectures based on these semiconductors were investigated for multijunction

  11. File System Virtual Appliances

    Science.gov (United States)

    2010-05-01

    System [80]. In Sun’s VFS paper, Kleiman stated that “Sun is currently discussing with AT&T and Berkeley the merging of this interface with AT&T’s File...26] DeBergalis, M., Corbett, P., Kleiman , S., Lent, A., Noveck, D., Talpey, T., and Wittle, M. 2003. The Direct Access File System. In Conference on...Users Group Meeting. 481–496. [51] Katcher, J. 1997. PostMark: A New File System Benchmark. Tech. Rep. TR3022, Network Appliance. October. [52] Kleiman , S

  12. Effect of material variation on the biomechanical behaviour of orthodontic fixed appliances: a finite element analysis.

    Science.gov (United States)

    Papageorgiou, Spyridon N; Keilig, Ludger; Hasan, Istabrak; Jäger, Andreas; Bourauel, Christoph

    2016-06-01

    Biomechanical analysis of orthodontic tooth movement is complex, as many different tissues and appliance components are involved. The aim of this finite element study was to assess the relative effect of material alteration of the various components of the orthodontic appliance on the biomechanical behaviour of tooth movement. A three-dimensional finite element solid model was constructed. The model consisted of a canine, a first, and a second premolar, including the surrounding tooth-supporting structures and fixed appliances. The materials of the orthodontic appliances were alternated between: (1) composite resin or resin-modified glass ionomer cement for the adhesive, (2) steel, titanium, ceramic, or plastic for the bracket, and (3) β-titanium or steel for the wire. After vertical activation of the first premolar by 0.5mm in occlusal direction, stress and strain calculations were performed at the periodontal ligament and the orthodontic appliance. The finite element analysis indicated that strains developed at the periodontal ligament were mainly influenced by the orthodontic wire (up to +63 per cent), followed by the bracket (up to +44 per cent) and the adhesive (up to +4 per cent). As far as developed stresses at the orthodontic appliance are concerned, wire material had the greatest influence (up to +155 per cent), followed by bracket material (up to +148 per cent) and adhesive material (up to +8 per cent). The results of this in silico study need to be validated by in vivo studies before they can be extrapolated to clinical practice. According to the results of this finite element study, all components of the orthodontic fixed appliance, including wire, bracket, and adhesive, seem to influence, to some extent, the biomechanics of tooth movement. © The Author 2015. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  13. Mobile based Appliances switching using Bluetooth

    Science.gov (United States)

    Gupta, Sureshchandra J., Dr; Desai, Kalp; Gaikawad, Deepak; Pawar, Vijay N.; Gangal, Devendranath R.

    2008-04-01

    How many times do you have to get up from your desk to switch on your Air conditioner or fan when you are completely into your table work? How many times do you feel lazy to get off your comfort to switch on/off your home appliances in different rooms? How much energy do you lose in a day for operating your appliances? The solution is either a large amount of manual work—or the idea that is presented over here: APP-CON (APP-CON stands for appliances control). Here the ordinary cell phone with bluetooth capability acts as remote designed in such a manner that it acts as a helping hand to human by reducing its manual work and therefore saving human energy. The cell phone control of APP-CON units lets you access many of your home appliances situated in different rooms by using just a single remote from distance. Electronics hobbyists would love to make such a remote control themselves. But they find it difficult due to complex circuitry rather than the high cost because of using a number of frequency counting techniques and decade counters. The APP-CON system given here overcomes the aforesaid problems by using a single microcontroller and moreover a simple program or software for bluetooth enabled cell phone and employing simple coding and decoding of remote signals. Here the mobile based remote control is used to operate a number of home appliances basically consists of Bluetooth technology. The unit consists of a transmitter and a receiver consisting of a microcontroller. The importance of bluetooth technology is that the signal to be transmitted from transmitter to the receiver is done without requiring line of sight.

  14. Remote repair appliance

    International Nuclear Information System (INIS)

    Heumann, F.K.; Wilkinson, J.C.; Wooding, D.R.

    1997-01-01

    A remote appliance for supporting a tool for performing work at a work site on a substantially circular bore of a work piece and for providing video signals of the work site to a remote monitor comprises: a base plate having an inner face and an outer face; a plurality of rollers, wherein each roller is rotatably and adjustably attached to the inner face of the base plate and positioned to roll against the bore of the work piece when the base plate is positioned against the mouth of the bore such that the appliance may be rotated about the bore in a plane substantially parallel to the base plate; a tool holding means for supporting the tool, the tool holding means being adjustably attached to the outer face of the base plate such that the working end of the tool is positioned on the inner face side of the base plate; a camera for providing video signals of the work site to the remote monitor; and a camera holding means for supporting the camera on the inner face side of the base plate, the camera holding means being adjustably attached to the outer face of the base plate. In a preferred embodiment, roller guards are provided to protect the rollers from debris and a bore guard is provided to protect the bore from wear by the rollers and damage from debris. 5 figs

  15. Improvements in appliance holders

    International Nuclear Information System (INIS)

    Chapman, J.E.

    1977-01-01

    Reference is made to appliance holders for locating tools, instruments, etc. in operative relationship to workpieces and accessible through passageways of restricted transverse dimensions. The appliance holder described comprises an elongated external frame provided with transversely, outwardly expanding frictional gripping means in two longitudinally spaced sets and with a ring of spur teeth. An inner elongated frame is held within the external frame in two longitudinally spaced rotary bearings and carries a spur wheel which engages the ring of the spur teeth. A motor is arranged to rotate the spur wheel and hence the inner frame in relation to the external frame. A carriage is carried by the inner frame, longitudinally movable by a motor in relation thereto, and a further carriage is mounted on this first carriage. This second cariage is transversely movable in relation to the inner frame and is provided with a face plate for attachment of tools, instruments, etc. A motor is mounted on the first carriage for moving the second carriage. (U.K.)

  16. Major Appliance Repair. Teacher Edition.

    Science.gov (United States)

    Smreker, Eugene; Calvert, King

    This module is a comprehensive text on basic appliance repair, designed to prepare students for entry-level jobs in this growing field. Ensuring a firm grounding in electrical knowledge, the module contains 13 instructional units that cover the following topics: (1) major appliance repair orientation; (2) safety and first aid; (3) fundamentals of…

  17. Non-Intrusive Appliance Recognition

    NARCIS (Netherlands)

    Hoogsteen, G; Hoogsteen, Gerwin; Krist, J.O.; Bakker, Vincent; Smit, Gerardus Johannes Maria

    2012-01-01

    Energy conservation becomes more important nowadays. The use of smart meters and, in the near future, smart appliances, are the key to achieve reduction in energy consumption. This research proposes a non-intrusive appliance monitor and recognition system for implementation on an embedded system.

  18. Corrosion of weldments in orthodontic appliances

    International Nuclear Information System (INIS)

    Vazquez, S.M.; Riesgo, O.; Duffo, G.S.

    1997-01-01

    The study of corrosion-related problems of dental materials has undergone a considerable development in recent years in order to avoid the use of materials with insufficient corrosion resistance in patients mouth. The subject of the present work was to study a particular type of corrosion: galvanic corrosion. One of the most common case of galvanic couples in patients mouth are the orthodontic appliances. The materials studied in the present work were stainless steel strips and silver-copper wires, isolated and welded between them. The electrochemical tests were performed in a NaCl 0.1M and Lactic Acid 0.1 M solution (pH2.3), and after test, the specimens were observed using the optical and scanning electron microscope. The results show that when stainless steel is coupled with a silver solder, the last is the anode of the galvanic couple. As a consequence of this, the silver solder undergone a severe attack. Stainless steel orthodontic appliances with silver solder are feasibly destroyed due to a severe attack on the filler metal disjoining the welded parts. (author) 9 refs

  19. Nickel release from orthodontic retention wires: the action of mechanical loading and pH

    NARCIS (Netherlands)

    Milheiro, A.; Kleverlaan, C.; Muris, J.; Feilzer, A.; Pallav, P.

    2012-01-01

    Nickel (Ni) is a potent sensitizer and may induce innate and adaptive immune responses. Ni is an important component of orthodontic appliances (8-50 wt%). Due to chemical and mechanical factors in the oral environment, Ni is released from these appliances. Retention wires are in situ for a long

  20. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  1. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  2. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  3. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  4. Transforce lingual appliances pre-adjusted invisible appliances simplify treatment.

    Science.gov (United States)

    Clark, William John

    2011-01-01

    Transforce lingual appliances are designed to be used in conjunction with conventional fixed appliances. Lingual arch development is normally followed by bonded fixed appliances to detail the occlusion. Alternatively Transforce appliance treatment is an efficient method of preparing complex malocclusions prior to a finishing stage with invisible appliances. This approach is ideal for adult treatment, using light continuous forces for arch development with appliances that are comfortable to wear. Sagittal and Transverse appliances are designed for arch development in a range of sizes for contracted arches. They can be used to treat all classes of malocclusion and are pre-adjusted fixed/removable devices for non-compliance treatment. Force modules with nickel titanium coil springs enclosed in a tube deliver a gentle, biocompatible continuous force with a long range of action. They are excellent for mixed dentition and ideal for adult arch development. There are multiple sizes for upper and lower arch development and a sizing chart may be placed over a study model for correct selection, eliminating the need for laboratory work.

  5. Does the insertion of more than one wire allow successful excision of large clusters of malignant calcification?

    Energy Technology Data Exchange (ETDEWEB)

    Cordiner, C.M.; Litherland, J.C.; Young, I.E

    2006-08-15

    AIM: To determine whether the insertion of more than one localization wire for larger areas of malignant microcalcification reduces the need for re-excision. METHOD: This is a retrospective study of 101 cases of malignant calcifications preoperatively marked by one or more wires. Surgical and histopathology data were obtained from hospital records. Mammograms and specimen radiographs were evaluated without knowledge of the eventual outcome, i.e., whether further surgery was required or not. All cases had a preoperative diagnosis of malignancy. RESULT: In this study the group of patients in which two or more wires were inserted had mammographically larger lesions (p < 0.000001) but did not have a greater chance of needing re-excision (p = 0.822). Mammograms that demonstrated flecks of microcalcification outlying the main cluster were also more likely to require further surgery (p < 0.01). Calcifications associated with high-grade ductal carcinoma in situ (DCIS) had three times the risk of requiring further surgery (p < 0.01). However, as reported in other studies re-excision was not related to breast size (p = 0.63) [Kollias J, Gill PG, Beamond B, Rossi H, Langlois S, Vernon-Roberts E. Clinical and radiological predictors of complete excision in breast-conserving surgery for primary breast cancer. Aust N Z J Surg 1998;68:702-6]. CONCLUSION: It was previously suggested that the risk of re-excision for DCIS is related to the size of the initial lesion [Cheng L, Al-Kaisi NK, Gordon NH, Liu AY, Gebrail F, Shenk RR. Relationship between the size and margins of ductal carcinoma in situ of the breast and residual disease. J Nat Cancer Inst 1997;89:1356-60]. However, in the present study larger clusters of microcalcification that have been 'bracketed' by two or more wires do not appear to have a greater requirement for re-excision. Grading of the malignant microcalcifications preoperatively may encourage the surgeon to take a wider margin. Careful examination of

  6. An orthodontic oral appliance.

    Science.gov (United States)

    Marklund, Marie; Legrell, Per Erik

    2010-11-01

    This pilot study was performed to test the hypothesis that an orthodontic oral appliance (OA) that is designed to work against the backwardly directed forces on the upper incisors may counteract the reduction in overjet from these devices. Thirty patients with normal bites, good oral health, and milder sleep apnea were randomized to treatment with either OAs or orthodontic OAs. Bite changes were evaluated on plaster casts and radiographs and by questionnaires after a mean of 2.4 years in 19 frequent users. Four of nine patients in the orthodontic OA group increased their overjet by > or =0.4 mm, while none of the 10 patients in the OA group experienced that effect. Only the orthodontic OA increases the overjet; this design may therefore be beneficial to patients at risk of negative effects on their bite during OA treatment.

  7. Adverse reactions to orthodontic appliances in nickel-allergic patients.

    Science.gov (United States)

    Volkman, Kristen K; Inda, Michael J; Reichl, Peter G; Zacharisen, Michael C

    2007-01-01

    Nickel allergy (NA) is common and causes more cases of allergic contact dermatitis (ACD) than all other metals combined. Many orthodontic appliances (ODAs) contain nickel but their clinical relevance in nickel-allergic patients is unclear. We aimed to characterize the relationship between NA and ODAs because the medical literature investigating this is controversial. A survey concerning adverse reactions to ODAs in patients with NA was distributed to members of the Wisconsin Society of Orthodontics. Forty-three surveys were analyzed. The surveyed group was experienced, representing a mean of 21.2 years in practice and averaging 242 appliances placed per year per orthodontist. Most new patients with orthodontia were 10-18 years old. Most wires used were nickel-titanium alloy. Although 76% of orthodontists inquired about NA at initial evaluation, 37% still placed nickel-containing ODAs in known nickel-allergic patients. Fifty percent placed a single intraoral appliance, observing for reactions. Three orthodontists applied ODAs to the skin similar to patch testing. Only 8 patients with reactions to ODAs were described in detail, 6 were female patients and 6 were aged 13-14 years. Intraoral and extraoral reactions were mild; diffuse urticaria was reported in one patient. Treatment included removing the appliances or changing to nonnickel alternatives with favorable outcomes. These cases, which included >33,000 patients, suggest a prevalence of 0.03%. Adverse reactions to ODAs in patients with NA have been observed but are uncommon. Using suitable alternatives, patients usually can be accommodated.

  8. Removable orthodontic appliance with nickel-titanium spring to reposition the upper incisors in an autistic patient.

    Science.gov (United States)

    Saito, Kan; Jang, Insan; Kubota, Kazumi; Hoshino, Tomonori; Hotokezaka, Hitoshi; Yoshida, Noriaki; Fujiwara, Taku

    2013-01-01

    A newly designed removable appliance with a shape-memory wire was used for the orthodontic treatment of the anterior teeth in an 11-year-old child who had autism and intellectual disability. The device was designed to reduce the lateral incisor crossbite and the central incisors' labial rotation. The child was treated for 1 year with this removable appliance. Tooth movement was analyzed using cephalograms and surface data were derived from study models. This device proved to be very durable. The lateral incisor crossbite was corrected, and the inclination of the upper central incisors and the interincisal angle were improved. This appliance exerts light and continuous orthodontic force, without requiring any adjustments of the spring wire. The appliance also facilitated orthodontic treatment in a child with intellectual disability in whom treatment with a standard orthodontic device would be unsuitable. ©2012 Special Care Dentistry Association and Wiley Periodicals, Inc.

  9. Lingual orthodontic appliances: invisible braces.

    Science.gov (United States)

    Muir, J C

    1991-04-01

    Lingual orthodontics is a relatively new method of delivering orthodontic treatment. These appliances may be used on any patient, but they have a special application for that small group of adult patients who need orthodontic treatment but refuse to accept the appearance of conventional appliances. The technique is difficult to manage and should be used only by experienced orthodontists. Although the patients may experience difficulties, these are usually adequately compensated for by the improved aesthetics.

  10. Orthodontic treatment with a series of removable appliances.

    Science.gov (United States)

    Chenin, David A; Trosien, Andrew H; Fong, Patricia F; Miller, Robert A; Lee, Rodney S

    2003-09-01

    In the United States, the demand for straight white teeth has never been more important to patients. Crowded, poorly aligned teeth are not esthetically pleasing and are difficult to keep clean. However, until recently, the process of straightening the teeth typically has involved appliances involving bands, brackets and wires that also can be difficult to clean. The desire for a cosmetic solution to misaligned teeth has led to an increase in the number of patients seeking veneers, crowns and other laboratory-fabricated cosmetic restorations. Some clinicians are not aware that there are other ways to align teeth without either significant enamel reduction or conspicuous fixed orthodontic appliances. An alternative method of treatment, involving a series of clear removable appliances, circumvents this shortcoming and enables tooth alignment while avoiding deterioration in the cosmetics of the smile during treatment. This article describes a method of treatment, Invisalign (Align Technology, Santa Clara, Calif.), that clinicians can use in conjunction with 3-D computer models to accomplish the esthetic and oral hygiene objectives during and after treatment. The authors present three case reports, all involving a chief concern of crowding. The first case involved treatment of both arches by interproximal reduction, alignment of teeth and leveling the curve of Spee. The second case involved treatment of both arches by proclination, expansion and minor interproximal reduction. The final case shows relief of lower-arch crowding via lower-incisor extraction. In addition to satisfying the patient's chief concern of desiring straight teeth, this method of treatment satisfies additional objectives of esthetic treatment and esthetic results with significant oral hygiene benefits. Clinicians can address a patient's chief concern effectively without requiring an inventory of appliances (such as bands, brackets, wires and instruments). Furthermore, the use of 3-D computer models

  11. PAT portable appliance testing

    CERN Document Server

    2011-01-01

    The Electricity at Work Regulations 1989 require any electrical system to be constructed, maintained and used in such a manner as to prevent danger. This means that inspection and testing of systems, including portable appliances, is needed in order to determine if maintenance is required.This book explains in clear language what needs to be done and includes expert advice on legislation as well as actual testing. The book contains an appendix providing the electrical fundamentals needed by non-specialists and also has sample questions (with answers) for the C&G 2377 exam that anyone who conducts this work is required to take by law.It is an affordable and handy reference for electricians who administer PAT. It is also an ideal refesher and revision guide for the non-specialist, such as maintenance staff, caretakers and charity shop volunteers who carry out these tasks part-time, alongside their many other duties.Brian Scaddan, I Eng, MIET, is a consultant for and an Honorary Member of City & Guilds. ...

  12. Management of class II malocclusion in an adolescent patient with “The Poosh Appliance”: An in office fabricated fixed functional appliance

    Directory of Open Access Journals (Sweden)

    Poonam K Manik

    2017-01-01

    Full Text Available Class II malocclusions with mandibular retrognathism are best managed with functional orthopedic appliances. Patients reporting before peak pubertal growth are treated with removable functional appliances. Young adults or Class II patients in late adolescence have been treated most effectively using fixed functional appliances (FFAs in combination with fixed orthodontic appliance. In such patients, some skeletal changes but largely dentoalveolar changes account for the treatment results. Most of the readily available FFAs have high cost or require laboratory fabrication. Both mandibular protraction appliance (MPA and churro jumper appliance are in-office-fabricated FFAs. The Poosh appliance is a newly designed in-office-fabricated FFA. It is a modification of the popular churro jumper appliance. This article presents the design, fabrication, and use of Poosh appliance in a 15-year-old male patient to manage Class II malocclusion successfully.

  13. Electric emissions from electrical appliances

    International Nuclear Information System (INIS)

    Leitgeb, N.; Cech, R.; Schroettner, J.

    2008-01-01

    Electric emissions from electric appliances are frequently considered negligible, and standards consider electric appliances to comply without testing. By investigating 122 household devices of 63 different categories, it could be shown that emitted electric field levels do not justify general disregard. Electric reference values can be exceeded up to 11-fold. By numerical dosimetry with homogeneous human models, induced intra-corporal electric current densities were determined and factors calculated to elevate reference levels to accounting for reduced induction efficiency of inhomogeneous fields. These factors were found not high enough to allow generally concluding on compliance with basic restrictions without testing. Electric appliances usually simultaneously emit both electric and magnetic fields exposing almost the same body region. Since the sum of induced current densities is limited, one field component reduces the available margin for the other. Therefore, superposition of electric current densities induced by either field would merit consideration. (authors)

  14. Documentation of Appliances & Interaction Devices

    DEFF Research Database (Denmark)

    2004-01-01

    The interaction devices and appliances explored in the WorkSPACE project, address spatial computing in the context of work. We have developed and explored a range of appliances and interaction devices. The scope has been to develop tools for support of collaboration by mixing digital and physical...... materials and environments. This has been done by the use of existing hardware technologies in novel combinations, controlled and mediated in the software applications we have developed. These developments, (the SpacePanel, the TagTable and ProjecTable , the SitePack and the software application Topos...

  15. Full 3-dimensional digital workflow for multicomponent dental appliances: A proof of concept.

    Science.gov (United States)

    van der Meer, W Joerd; Vissink, Arjan; Ren, Yijin

    2016-04-01

    The authors used a 3-dimensional (3D) printer and a bending robot to produce a multicomponent dental appliance to assess whether 3D digital models of the dentition are applicable for a full digital workflow. The authors scanned a volunteer's dentition with an intraoral scanner (Lava Chairside Oral Scanner C.O.S., 3M). A digital impression was used to design 2 multicomponent orthodontic appliances. Biocompatible acrylic baseplates were produced with the aid of a 3D printer. The metal springs and clasps were produced by a bending robot. The fit of the 2 appliances was assessed by 2 experienced orthodontists. The authors assessed both orthodontic appliances with the volunteer's dentition and found the fit to be excellent. Clinicians can fully produce a multicomponent dental appliance consisting of both an acrylic baseplate and other parts, such as clasps, springs, or screws, using a digital workflow process without the need for a physical model of the patient's dentition. Plaster models can be superfluous for orthodontic treatment as digital models can be used in all phases of a full digital workflow in orthodontics. The arduous task of making a multicomponent dental appliance that involves bending wires can possibly be replaced by a computer, design software, a 3D printer, and a bending robot. Copyright © 2016 American Dental Association. Published by Elsevier Inc. All rights reserved.

  16. Peer Instruction versus Class-Wide Discussion in Large Classes: A Comparison of Two Interaction Methods in the Wired Classroom.

    Science.gov (United States)

    Nicol, David J.; Boyle, James T.

    2003-01-01

    Classroom communication system (CCS) technology makes it easier to give students immediate feedback on concept tests and to manage peer and class discussions in large classes. This study compared the effects of two different CCS discussion sequences on students' experiences of learning engineering. The results demonstrated that the type of…

  17. An Iterative Load Disaggregation Approach Based on Appliance Consumption Pattern

    Directory of Open Access Journals (Sweden)

    Huijuan Wang

    2018-04-01

    Full Text Available Non-intrusive load monitoring (NILM, monitoring single-appliance consumption level by decomposing the aggregated energy consumption, is a novel and economic technology that is beneficial to energy utilities and energy demand management strategies development. Hardware costs of high-frequency sampling and algorithm’s computational complexity hampered NILM large-scale application. However, low sampling data shows poor performance in event detection when multiple appliances are simultaneously turned on. In this paper, we contribute an iterative disaggregation approach that is based on appliance consumption pattern (ILDACP. Our approach combined Fuzzy C-means clustering algorithm, which provide an initial appliance operating status, and sub-sequence searching Dynamic Time Warping, which retrieves single energy consumption based on the typical power consumption pattern. Results show that the proposed approach is effective to accurately disaggregate power consumption, and is suitable for the situation where different appliances are simultaneously operated. Also, the approach has lower computational complexity than Hidden Markov Model method and it is easy to implement in the household without installing special equipment.

  18. Invisible orthodontics part 2: lingual appliance treatment.

    Science.gov (United States)

    McMullin, Ailbhe; Waring, David; Malik, Ovais

    2013-06-01

    The aim of this second article of the three part series is to sum up the current developments in lingual orthodontics. This article attempts to review the development, advantages and disadvantages, bonding techniques, bracket mechanics, patient factors and types of lingual appliance systems available. In addition, the article shows examples of treated cases with lingual appliances. Lingual appliances are a useful addition to the armamentarium of invisible orthodontic appliances, with significant developments over the last few years. Clinicians need to be aware of the advances and predictable results achievable with lingual appliances.

  19. Torque differences due to the material variation of the orthodontic appliance: a finite element study.

    Science.gov (United States)

    Papageorgiou, Spyridon N; Keilig, Ludger; Vandevska-Radunovic, Vaska; Eliades, Theodore; Bourauel, Christoph

    2017-12-01

    Torque of the maxillary incisors is crucial to occlusal relationship and esthetics and can be influenced by many factors. The aim of this study was to assess the relative influence of the material of the orthodontic appliance (adhesive, bracket, ligature, and wire) on tooth displacements and developed stresses/strains after torque application. A three-dimensional upper right central incisor with its periodontal ligament (PDL) and alveolus was modeled. A 0.018-in. slot discovery® (Dentaurum, Ispringen, Germany) bracket with a rectangular 0.018 x 0.025-in. wire was generated. The orthodontic appliance varied in the material of its components: adhesive (composite resin or resin-modified glass ionomer cement), bracket (titanium, steel, or ceramic), wire (beta-titanium or steel), and ligature (elastomeric or steel). A total of 24 models were generated, and a palatal root torque of 5° was applied. Afterwards, crown and apex displacement, strains in the PDL, and stresses in the bracket were calculated and analyzed. The labial crown displacement and the palatal root displacement of the tooth were mainly influenced by the material of the wire (up to 150% variation), followed by the material of the bracket (up to 19% variation). The magnitude of strains developed in the PDL was primarily influenced by the material of the wire (up to 127% variation), followed by the material of the bracket (up to 30% variation) and the ligature (up to 13% variation). Finally, stresses developed at the bracket were mainly influenced by the material of the wire (up to 118% variation) and the bracket (up to 59% variation). The material properties of the orthodontic appliance and all its components should be considered during torque application. However, these in silico results need to be validated in vivo before they can be clinically extrapolated.

  20. Torque differences due to the material variation of the orthodontic appliance: a finite element study

    Directory of Open Access Journals (Sweden)

    Spyridon N. Papageorgiou

    2017-02-01

    Full Text Available Abstract Background Torque of the maxillary incisors is crucial to occlusal relationship and esthetics and can be influenced by many factors. The aim of this study was to assess the relative influence of the material of the orthodontic appliance (adhesive, bracket, ligature, and wire on tooth displacements and developed stresses/strains after torque application. Methods A three-dimensional upper right central incisor with its periodontal ligament (PDL and alveolus was modeled. A 0.018-in. slot discovery® (Dentaurum, Ispringen, Germany bracket with a rectangular 0.018 x 0.025-in. wire was generated. The orthodontic appliance varied in the material of its components: adhesive (composite resin or resin-modified glass ionomer cement, bracket (titanium, steel, or ceramic, wire (beta-titanium or steel, and ligature (elastomeric or steel. A total of 24 models were generated, and a palatal root torque of 5° was applied. Afterwards, crown and apex displacement, strains in the PDL, and stresses in the bracket were calculated and analyzed. Results The labial crown displacement and the palatal root displacement of the tooth were mainly influenced by the material of the wire (up to 150% variation, followed by the material of the bracket (up to 19% variation. The magnitude of strains developed in the PDL was primarily influenced by the material of the wire (up to 127% variation, followed by the material of the bracket (up to 30% variation and the ligature (up to 13% variation. Finally, stresses developed at the bracket were mainly influenced by the material of the wire (up to 118% variation and the bracket (up to 59% variation. Conclusions The material properties of the orthodontic appliance and all its components should be considered during torque application. However, these in silico results need to be validated in vivo before they can be clinically extrapolated.

  1. DNA damage in oral mucosa cells of patients with fixed orthodontic appliances.

    Directory of Open Access Journals (Sweden)

    Farzin Heravi

    2013-12-01

    Full Text Available The release of toxic metal ions from orthodontic alloys has induced concerns regarding the biocompatibility of fixed appliances. This study investigated the genotoxic effect of metal appliances in a sample of patients undergoing fixed orthodontic treatment.The study included twenty-five healthy individuals requiring orthodontic therapy in both jaws. The patients were treated by stainless steel orthodontic brackets and nickel-titanium or stainless steel arch wires. The oral mucosa cells were gathered just before the appliance placement and 9 months later. The cells were centrifuged, fixed and dropped onto slides. After staining, the micronucleus (MN assay was used to determine genome alteration. The data were analyzed by paired sample t-test.The mean micronuclei frequency in the buccal mucosa was 10.6 ± 5.7 per 1000 cells before the appliance placement and 9.2 ± 6.37 per 1000 cells 9 months later. No significant difference was found in the MN count before and 9 months after therapy (p=0.336.Under the conditions used in this study, application of fixed orthodontic appliances did not expose healthy individuals to increased risk of DNA damage in oral mucosa cells.

  2. Overview on PIV Application to Appliances

    Science.gov (United States)

    Tomasini, Enrico Primo; Paone, Nicola; Rossi, Massimiliano; Castellini, Paolo

    The term appliances describes a wide range of products that are used to perform a wide variety of tasks. In the home environment, household appliances like refrigerators, ovens, washing machines, dishwashers, vacuum cleaners, hair driers are sold in million pieces per year; they also have commercial and industrial application. Typical products of the appliance industry have a relatively low industrial cost and the appliance market shows a strong competition, in which appliance technical performance plays a role together with aesthetics and costs. Therefore, efforts in applied research for product technical improvement can be done only if the ratio cost to benefits is advantageous. Many such appliances have complex fluid-dynamic problems; it is important that any experimental technique bears inherent characteristics of simplicity, provides a rapid means to collect experimental data, provides information that engineers can readily exploit for product enhancement, and mostly for computational fluid-dynamic (CFD) code validation. Particle image velocimetry (PIV) satisfies most of the above-mentioned requirements and therefore appears as a good candidate experimental technique to be proposed in the field of appliances. Nevertheless, PIV applications are rare. The PIVNet2 workshop on "PIV application to appliances" that took place in Ancona on June 2003 intended to illustrate the great potential for application of the PIV technique in this sector. This chapter presents an overview of PIV application to appliances according to the outcome from this workshop.

  3. Low-complexity energy disaggregation using appliance load modelling

    Directory of Open Access Journals (Sweden)

    Hana Altrabalsi

    2016-01-01

    Full Text Available Large-scale smart metering deployments and energy saving targets across the world have ignited renewed interest in residential non-intrusive appliance load monitoring (NALM, that is, disaggregating total household’s energy consumption down to individual appliances, using purely analytical tools. Despite increased research efforts, NALM techniques that can disaggregate power loads at low sampling rates are still not accurate and/or practical enough, requiring substantial customer input and long training periods. In this paper, we address these challenges via a practical low-complexity lowrate NALM, by proposing two approaches based on a combination of the following machine learning techniques: k-means clustering and Support Vector Machine, exploiting their strengths and addressing their individual weaknesses. The first proposed supervised approach is a low-complexity method that requires very short training period and is fairly accurate even in the presence of labelling errors. The second approach relies on a database of appliance signatures that we designed using publicly available datasets. The database compactly represents over 200 appliances using statistical modelling of measured active power. Experimental results on three datasets from US, Italy, Austria and UK, demonstrate the reliability and practicality.

  4. Noncontextual Wirings

    Science.gov (United States)

    Amaral, Barbara; Cabello, Adán; Cunha, Marcelo Terra; Aolita, Leandro

    2018-03-01

    Contextuality is a fundamental feature of quantum theory necessary for certain models of quantum computation and communication. Serious steps have therefore been taken towards a formal framework for contextuality as an operational resource. However, the main ingredient of a resource theory—a concrete, explicit form of free operations of contextuality—was still missing. Here we provide such a component by introducing noncontextual wirings: a class of contextuality-free operations with a clear operational interpretation and a friendly parametrization. We characterize them completely for general black-box measurement devices with arbitrarily many inputs and outputs. As applications, we show that the relative entropy of contextuality is a contextuality monotone and that maximally contextual boxes that serve as contextuality bits exist for a broad class of scenarios. Our results complete a unified resource-theoretic framework for contextuality and Bell nonlocality.

  5. Impacts of appliance efficiency standards

    Energy Technology Data Exchange (ETDEWEB)

    Hummel, P.; Kesselring, J.

    1992-12-01

    Federal efficiency standards for appliances limit the range of models available on the market. Utility energy efficiency programs often encourage consumers to purchase the most efficient of the remaining options, but more-stringent efficiency standards could have a significant impact on such utility efforts. Using long-run technology scenario forecasting, EPRI-sponsored researchers studied ways in which the interplay of technological change, federal standards, utility efficiency programs, and market forces could affect future energy markets for three major residential end uses: refrigeration, central air conditioning, and water heating. The researchers reached several important conclusions about utility demand-side management efforts. 2 figs., 1 tab.

  6. 49 CFR 238.429 - Safety appliances.

    Science.gov (United States)

    2010-10-01

    ... appliance mechanical strength and fasteners. (1) All handrails, handholds, and sill steps shall be made of 1-inch diameter steel pipe, 5/8-inch thickness steel, or a material of equal or greater mechanical strength. (2) All safety appliances shall be securely fastened to the car body structure with mechanical...

  7. Minat Masyarakat dalam Menggunakan Smart Appliances

    Directory of Open Access Journals (Sweden)

    Diah Yuniarti

    2014-09-01

    Full Text Available Harga sumber energi yang semakin naik dari tahun ke tahun dan kemajuan teknologi telah mendorong perkembangan smart grid. Smart appliance merupakan salah satu komponen penting dalam smart grid. Penerapan smart appliance sejalan dengan kebijakan untuk mengurangi konsumsi energi, mengurangi emisi karbon dan penyediaan energi dari energi terbarukan. Penetrasi telepon bergerak turut memudahkan manajemen energi dan otomatisasi home appliance. Penelitian ini dilakukan untuk menganalisis minat masyarakat, yang merupakan aktor aktif dalam konsumsi dan manajemen energi di rumah tangga. Data penelitian dianalisis  dengan menggunakan metode structural equation modeling (SEM Hasil penelitian menunjukkan bahwa variabel enjoyment memiliki pengaruh yang signifikan terhadap minat dalam menggunakan smart appliance. Sedangkan, variabel compatibility ease of use, relative advantage dan image tidak memiliki pengaruh yang signifikan terhadap minat menggunakan smart appliance.

  8. [Patients' experiences with the Forsus appliance].

    Science.gov (United States)

    Tian, Xiao-guang; Wu, Zi-zhong; Zhang, Shi-jie; Zhang, Miao; Lin, Xian-jun

    2014-04-01

    To investigate patients' experiences with the Forsus appliance. This questionnaire survey was focused on patients' comprehensive experiences with Forsus, both initially and after several months of wearing, including the patients' overall impressions of the appliance. The survey was conducted in 64 patients wearing Forsus. A high percentage of patients(83.7%) reported neutral to favorable experience with Forsus. 85.4% of patients reported gradual adaption to the appliance within 4 weeks. Cheek irritation was the most serious side effect (about 52%). Cheek irritation and other side effect disappeared over time. The Forsus appliance is relatively well accepted by patients. Most patients experience some discomfort and functional limitations at first. However, the side effect gradually diminishes with time, and the patients adapt to the appliance finally. Practitioners should be especially vigilant about problems of cheek irritation.

  9. Characterization of electrical appliances in transient state

    Science.gov (United States)

    Wójcik, Augustyn; Winiecki, Wiesław

    2017-08-01

    The article contains the study about electrical appliance characterization on the basis of power grid signals. To represent devices, parameters of current and voltage signals recorded during transient states are used. In this paper only transients occurring as a result of switching on devices are considered. The way of data acquisition performed in specialized measurement setup developed for electricity load monitoring is described. The paper presents the method of transients detection and the method of appliance parameters calculation. Using the set of acquired measurement data and appropriate software the set of parameters for several household appliances operating in different operating conditions was processed. Usefulness of appliances characterization in Non-Intrusive Appliance Load Monitoring System (NIALMS) with the use of proposed method is discussed focusing on obtained results.

  10. Air conditioning with small power gas appliances

    International Nuclear Information System (INIS)

    Canci, Franco

    1997-01-01

    This article describes research and test activities on small power air conditioning appliances for residential use carried out in the United States, Japan and Europe. The absorption technology aims at the following objectives: to develop appliances requiring reduced maintenance and having a size comparable with electric units of the same output; to reduce production costs and therefore the final prince by adopting special manufacturing technologies such as welded plate exchangers; to obtain appliances which operate both in summer and winter ( as heat pumps), allowing to minimize management and installation costs in southern European climates. The final aim is to offer the customer one appliance only for the following purposes: hot water production for sanitary use, water refrigeration for summer air conditioning, hot water production production for winter heating. This kind of appliance should have management and maintenance costs similar to current individual boilers

  11. Stretched Wire Mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, Gordon; /SLAC

    2005-09-06

    Stretched wires are beginning to play an important role in the alignment of accelerators and synchrotron light sources. Stretched wires are proposed for the alignment of the 130 meter long LCLS undulator. Wire position technology has reached sub-micron resolution yet analyses of perturbations to wire straightness are hard to find. This paper considers possible deviations of stretched wire from the simple 2-dimensional catenary form.

  12. Fabrication of a resin appliance with alloy components using digital technology without an analog impression.

    Science.gov (United States)

    Al Mortadi, Noor; Jones, Quentin; Eggbeer, Dominic; Lewis, Jeffrey; Williams, Robert J

    2015-11-01

    The aim of this study was to fabricate a resin appliance incorporating "wire" components without the use of an analog impression and dental casts using an intraoral scanner and computer technology to build the appliance. This unique alignment of technology offers an enormous reduction in the number of fabrication steps when compared with more traditional methods of manufacture. The prototype incorporated 2 Adams clasps and a fitted labial bow. The alloy components were built from cobalt-chromium in an initial powdered form using established digital technology methods and then inserted into a build of a resin base plate. This article reports the first known use of computer-aided design and additive manufacture to fabricate a resin and alloy appliance, and constitutes proof of the concept for such manufacturing. The original workflow described could be seen as an example for many other similar appliances, perhaps with active components. The scan data were imported into an appropriate specialized computer-aided design software, which was used in conjunction with a force feedback (haptic) interface. The appliance designs were then exported as stereolithography files and transferred to an additive manufacturing machine for fabrication. The results showed that the applied techniques may provide new manufacturing and design opportunities in orthodontics and highlights the need for intraoral-specific additive manufacture materials to be produced and tested for biocompatibility compliance. In a trial, the retainer was fitted orally and judged acceptable by the clinician according to the typical criteria when placing such appliances in situ. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  13. Multi-kanban mechanism for appliance disassembly

    Science.gov (United States)

    Udomsawat, Gun; Gupta, Surendra M.

    2005-11-01

    The use of household appliances continues to rise every year. A significant number of End-Of-Life (EOL) appliances are generated because of the introduction of newer models that are more attractive, efficient and affordable. Others are, of course, generated when they become non-functional. Many regulations encourage recycling of EOL appliances to reduce the amount of waste sent to landfills. In addition, EOL appliances offer the appliance manufacturing and remanufacturing industries a source of less expensive raw materials and components. For this reason product recovery has become a subject of interest during the past decade. In this paper, we study the disassembly line for appliance disassembly. We discuss and incorporate some of the complications that are inherent in disassembly line including product arrival, demand arrival, inventory fluctuation and production control mechanisms. We show how to overcome such complications by implementing a multi-kanban system in the appliance disassembly line setting. The multi-kanban system (MKS) relies on dynamic routing of kanbans according to the state of the system. We investigate the multi-kanban mechanism using simulation and explore the effect of product mix on performance of the traditional push system (TPS) and MKS in terms of controlling the system's inventory while attempting to achieve a decent customer service level.

  14. The Micro Wire Detector

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M. E-mail: maximo.plo@cern.ch; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C

    1999-10-11

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 {mu}m{sup 2} apertures, crossed by 25 {mu}m anode strips to which it is attached by 50 {mu}m kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  15. Mapping chemical elements on the surface of orthodontic appliance by SEM-EDX.

    Science.gov (United States)

    Mikulewicz, Marcin; Wołowiec, Paulina; Michalak, Izabela; Chojnacka, Katarzyna; Czopor, Wojciech; Berniczei-Royko, Adam; Vegh, Andras; Gedrange, Thomas

    2014-05-25

    During orthodontic treatment, the various elements that constitute the fixed appliance undergo different processes. As a result of a change of the surface, elution/coverage of metals on the surface can be observed in the process of corrosion/passivation. Scanning electron microscopy with an energy-dispersive X-ray analytical system (SEM-EDX) was used to analyze the composition of stainless steel elements of orthodontic fixed appliances (before and after orthodontic treatment), to obtain the composition of the surface of the elements. The analyzed elements were: brackets (Victory Series APC PLUS 022, 3M Unitek, Monrovia, CA, USA); wires (0.017×0.025, 3M Unitek, Monrovia, CA, USA); and bands (37+, 3M Unitek, Monrovia, CA, USA). The results showed a decrease of chromium and iron contribution to the surface, with increase of oxygen content in used vs. new elements of the appliance. Our results confirm the formation of oxides (passivation layer) on the surface of stainless steel as a result of the presence of the orthodontic appliance in patients' oral cavities.

  16. Electrochemically synthesized Si nano wire arrays and thermoelectric nano structures

    International Nuclear Information System (INIS)

    Khuan, N.I.; Ying, K.K.; Nur Ubaidah Saidin; Foo, C.T.

    2012-01-01

    Thermoelectric nano structures hold great promise for capturing and directly converting into electricity some vast amount of low-grade waste heats now being lost to the environment (for example from nuclear power plant, fossil fuel burning, automotive and household appliances). In this study, large-area vertically-aligned silicon nano wire (SiNW) arrays were synthesized in an aqueous solution containing AgNO 3 and HF on p-type Si (100) substrate by self-selective electroless etching process. The etching conditions were systematically varied in order to achieve different stages of nano wire formation. Diameters of the SiNWs obtained varied from approximately 50 to 200 nm and their lengths ranged from several to a few tens of μm. Te/ Bi 2 Te 3 -Si thermoelectric core-shell nano structures were subsequently obtained via galvanic displacement of SiNWs in acidic HF electrolytes containing HTeO 2 + and Bi 3+ / HTeO 2 + ions. The reactions were basically a nano-electrochemical process due to the difference in redox potentials between the materials. the surface-modified SiNWs of core-shell structures had roughened surface morphologies and therefore, higher surface-t-bulk ratios compared to unmodified SiNWs. They have potential applications in sensors, photovoltaic and thermoelectric nano devices. Growth study on the SiNWs and core-shell nano structures produced is presented using various microscopy, diffraction and probe-based techniques for microstructural, morphological and chemical characterizations. (Author)

  17. Real time large scale in vivo observations reveal intrinsic synchrony, plasticity and growth cone dynamics of midline crossing axons during neuronal wiring of the zebrafish spinal cord.

    Science.gov (United States)

    Andersen, Søren S L

    2017-08-30

    How axons are wired in the vertebrate spinal cord has been studied mostly using fixed samples or looking at individually growing axons. Using light-sheet microscopy, early neural development is here followed in vivo in real time at high resolution along several hundred micrometers of the zebrafish spinal cord. The dynamics and time course of cellular development and axonal wiring of interneurons expressing GFP under control of the dmrt3 promotor are analyzed. Following neurulation, commissural axons are observed crossing the ventral floor plate midline perpendicularly at about 20 microns/h and in a manner dependent on the Robo3 but not the EphA4 receptors. Ipsilateral axons extend concurrently, at three to six times higher growth rates and independently of said receptors. At guidance points, commissural axons are seen to decrease their growth rate and cones increase in size. Commissural filopodia appear on the floor plate to interact with the nascent neural network, and thereby trigger immediate plastic and reversible sinusoidal-shaped bending movements of the neighboring commissural shafts. A 3D reconstruction of the 4 dpf spinal cord demonstrates variable dmrt3 cell body position and dimensions, confirmed by single cell FlowSight analysis, and also a minor second population of commissurals crossing later and more dorsally. The recordings show the strikingly stereotyped spatio-temporal control that governs axonal wiring of the zebrafish spinal cord. The live observations give renewed perspective on the mechanisms of axonal guidance in the spinal cord that provide for a discussion of the current distinction between diffusible long-range versus substrate-bound short-range guidance cues. This article is protected by copyright. All rights reserved. © 2017 Wiley Periodicals, Inc.

  18. Home Appliance Load Scheduling with SEMIAH

    DEFF Research Database (Denmark)

    Jacobsen, Rune Hylsberg; Ghasem Azar, Armin; Zhang, Qi

    2015-01-01

    The European research project SEMIAH aims at designing a scalable infrastructure for residential demand response. This paper presents the progress towards a centralized load scheduling algorithm for controlling home appliances taking power grid constraints and satisfaction of consumers into account....

  19. Enabling Graph Appliance for Genome Assembly

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Rina [ORNL; Graves, Jeffrey A [ORNL; Lee, Sangkeun (Matt) [ORNL; Sukumar, Sreenivas R [ORNL; Shankar, Mallikarjun [ORNL

    2015-01-01

    In recent years, there has been a huge growth in the amount of genomic data available as reads generated from various genome sequencers. The number of reads generated can be huge, ranging from hundreds to billions of nucleotide, each varying in size. Assembling such large amounts of data is one of the challenging computational problems for both biomedical and data scientists. Most of the genome assemblers developed have used de Bruijn graph techniques. A de Bruijn graph represents a collection of read sequences by billions of vertices and edges, which require large amounts of memory and computational power to store and process. This is the major drawback to de Bruijn graph assembly. Massively parallel, multi-threaded, shared memory systems can be leveraged to overcome some of these issues. The objective of our research is to investigate the feasibility and scalability issues of de Bruijn graph assembly on Cray s Urika-GD system; Urika-GD is a high performance graph appliance with a large shared memory and massively multithreaded custom processor designed for executing SPARQL queries over large-scale RDF data sets. However, to the best of our knowledge, there is no research on representing a de Bruijn graph as an RDF graph or finding Eulerian paths in RDF graphs using SPARQL for potential genome discovery. In this paper, we address the issues involved in representing a de Bruin graphs as RDF graphs and propose an iterative querying approach for finding Eulerian paths in large RDF graphs. We evaluate the performance of our implementation on real world ebola genome datasets and illustrate how genome assembly can be accomplished with Urika-GD using iterative SPARQL queries.

  20. Evaluation of scalp hair nickel and chromium level changes in patients with fixed orthodontic appliance: a one-year follow-up study.

    Science.gov (United States)

    Jamshidi, Saman; Rahmati Kamel, Manouchehr; Mirzaie, Maysam; Sarrafan, Ahmadreza; Khafri, Soraya; Parsian, Hadi

    2018-01-01

    The release of metal ions from orthodontic appliances is part of the dissolution and biomechanical processes of alloys. Nickel (Ni) and chromium (Cr) are the elements commonly used in the manufacture of various components of fixed orthodontic appliances, including bands, brackets and wires. This study was aimed to measure the Ni and Cr ions levels in the scalp hair of patients treated with fixed orthodontic appliances in comparison of the control group. The patient group consisted of 24 patients treated with fixed orthodontic appliances for one year, while the control group included 28 healthy individuals without orthodontic appliances. Analysis of the Cr and Ni was performed using atomic absorption spectrophotometer by graphite furnace method. The data were analyzed via student and paired samples t-test and ANOVA repeated measurement test. After one year, the levels of Ni and Cr in two groups showed significant differences (0.086 ± 0.007 and 0.258 ± 0.009 µg/g for control group and 0.149 ± 0.010 and 0.339 ± 0.013 µg/g for patient group, respectively for Ni and Cr, p orthodontic appliances and considering the cytotoxic and allergic effects of these ions, changing the ingredients in fixed orthodontic appliances is suggested for the future.

  1. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  2. Quality of Lab Appliances in Orthodontic Offices.

    Science.gov (United States)

    Pruzansky, D P; Park, J H

    Lab appliances are an integral part of orthodontics, from active treatment to retention. The quality and fit of an appliance can affect the treatment result and stability. This study aims to determine common points of failure in orthodontic appliances, and suggest methods to reduce this rate. A survey consisting of 23 questions was distributed to active members of the American Association of Orthodontists (AAO) via Survey Monkey. The most common appliance to need an adjustment was the wrap-around retainer, with the Hawley retainer as a close second. The least common appliance needing adjustment was the Essix/clear retainer. Respondents were asked which component of each appliance was most commonly responsible for an ill-fit. For Hawley and wrap-around retainers, clasps were the most common problem at 50%, whereas spring aligners had two components - clasps and labial bows, both at 38%. Ill-fitting Essix/clear retainers had gingival impingement (52%) closely followed by poor posterior seating (43%). Communication between the orthodontist and lab technician can be improved by establishing a quality assurance protocol for outgoing and incoming cases. The labial bow of Hawley's, wrap-arounds and spring aligners should be clearly demarcated on the casts. Impressions should be free of distortion and casts should be inspected for accuracy. Clear retainers and positioner should be trimmed to avoid gingival impingement. The type of clasp should be selected based on the anatomy of the teeth, and bands should be checked for accuracy of fit.

  3. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  4. Exposure from Appliances (invited paper)

    Energy Technology Data Exchange (ETDEWEB)

    Cartwright, R.A

    1999-07-01

    The dosemeter studies on exposures to ELF electromagnetic irradiation from domestic equipment all suggest the whole-body doses are low, whilst some exposure to extremities could be high but of brief duration. Old style electric overblankets, however, are an exception and produce high fields and relatively high whole-body doses if switched on during the night. Relatively few epidemiological studies have addressed these issues. All of the studies have associated problems of interpretations. Two isolated studies throw up on association with the frequency of spontaneous abortion and electric blanket use whilst another links adult AML and electric shaver usage. Both results could be fortuitous. More consistency appears from three studies of childhood leukaemia. Here statistically significant associations between electric blanket use in pregnancies appear in two separate studies, as does hair dryer use in the case of children: other appliances use associations have been reported. These results are critically assessed. The United Kingdom Childhood Cancer Study (UKCCS) addresses some of these issues as part of a wider ranging assessment of EMF at home and at school. External sources are incorporated with the measurement of domestic ambient conditions in an attempt to make an overall assessment of total exposure. (author)

  5. Exposure from Appliances (invited paper)

    International Nuclear Information System (INIS)

    Cartwright, R.A.

    1999-01-01

    The dosemeter studies on exposures to ELF electromagnetic irradiation from domestic equipment all suggest the whole-body doses are low, whilst some exposure to extremities could be high but of brief duration. Old style electric overblankets, however, are an exception and produce high fields and relatively high whole-body doses if switched on during the night. Relatively few epidemiological studies have addressed these issues. All of the studies have associated problems of interpretations. Two isolated studies throw up on association with the frequency of spontaneous abortion and electric blanket use whilst another links adult AML and electric shaver usage. Both results could be fortuitous. More consistency appears from three studies of childhood leukaemia. Here statistically significant associations between electric blanket use in pregnancies appear in two separate studies, as does hair dryer use in the case of children: other appliances use associations have been reported. These results are critically assessed. The United Kingdom Childhood Cancer Study (UKCCS) addresses some of these issues as part of a wider ranging assessment of EMF at home and at school. External sources are incorporated with the measurement of domestic ambient conditions in an attempt to make an overall assessment of total exposure. (author)

  6. Water Desalination with Wires

    NARCIS (Netherlands)

    Porada, S.; Sales, B.B.; Hamelers, H.V.M.; Biesheuvel, P.M.

    2012-01-01

    We show the significant potential of water desalination using a novel capacitive wire-based technology in which anode/cathode wire pairs are constructed from coating a thin porous carbon electrode layer on top of electrically conducting rods (or wires). By alternately dipping an array of electrode

  7. Mountain Plains Learning Experience Guide: Appliance Repair. Course: Heater-Type Appliances.

    Science.gov (United States)

    Ziller, T.

    One of two individualized courses included in an appliance repair curriculum (see CE 027 767), this course covers minor and major heater-type appliances. The course is comprised of six units: (1) Irons, (2) Roasters, (3) Space Heaters, (4) Water Heaters, (5) Electric Ranges, and (6) Gas Ranges. Each unit begins with a Unit Learning Experience…

  8. Cephalometric effects of the Jones Jig appliance followed by fixed appliances in Class II malocclusion treatment.

    Science.gov (United States)

    Patel, Mayara Paim; Henriques, José Fernando Castanha; Freitas, Karina Maria Salvatore; Grec, Roberto Henrique da Costa

    2014-01-01

    The aim of this study was to cephalometrically assess the skeletal and dentoalveolar effects of Class II malocclusion treatment performed with the Jones Jig appliance followed by fixed appliances. The sample comprised 25 patients with Class II malocclusion treated with the Jones Jig appliance followed by fixed appliances, at a mean initial age of 12.90 years old. The mean time of the entire orthodontic treatment was 3.89 years. The distalization phase lasted for 0.85 years, after which the fixed appliance was used for 3.04 years. Cephalograms were used at initial (T1), post-distalization (T2) and final phases of treatment (T3). For intragroup comparison of the three phases evaluated, dependent ANOVA and Tukey tests were used. Jones Jig appliance did not interfere in the maxillary and mandibular component and did not change maxillomandibular relationship. Jones Jig appliance promoted distalization of first molars with anchorage loss, mesialization and significant extrusion of first and second premolars, as well as a significant increase in anterior face height at the end of treatment. The majority of adverse effects that occur during intraoral distalization are subsequently corrected during corrective mechanics. Buccal inclination and protrusion of mandibular incisors were identified. By the end of treatment, correction of overjet and overbite was observed. Jones Jig appliance promoted distalization of first molars with anchorage loss represented by significant mesial movement and extrusion of first and second premolars, in addition to a significant increase in anterior face height.

  9. Cephalometric effects of the Jones Jig appliance followed by fixed appliances in Class II malocclusion treatment

    Science.gov (United States)

    Patel, Mayara Paim; Henriques, José Fernando Castanha; de Freitas, Karina Maria Salvatore; Grec, Roberto Henrique da Costa

    2014-01-01

    Objective The aim of this study was to cephalometrically assess the skeletal and dentoalveolar effects of Class II malocclusion treatment performed with the Jones Jig appliance followed by fixed appliances. Methods The sample comprised 25 patients with Class II malocclusion treated with the Jones Jig appliance followed by fixed appliances, at a mean initial age of 12.90 years old. The mean time of the entire orthodontic treatment was 3.89 years. The distalization phase lasted for 0.85 years, after which the fixed appliance was used for 3.04 years. Cephalograms were used at initial (T1), post-distalization (T2) and final phases of treatment (T3). For intragroup comparison of the three phases evaluated, dependent ANOVA and Tukey tests were used. Results Jones Jig appliance did not interfere in the maxillary and mandibular component and did not change maxillomandibular relationship. Jones Jig appliance promoted distalization of first molars with anchorage loss, mesialization and significant extrusion of first and second premolars, as well as a significant increase in anterior face height at the end of treatment. The majority of adverse effects that occur during intraoral distalization are subsequently corrected during corrective mechanics. Buccal inclination and protrusion of mandibular incisors were identified. By the end of treatment, correction of overjet and overbite was observed. Conclusions Jones Jig appliance promoted distalization of first molars with anchorage loss represented by significant mesial movement and extrusion of first and second premolars, in addition to a significant increase in anterior face height. PMID:25162565

  10. Orthodontic appliance preferences of children and adolescents.

    Science.gov (United States)

    Walton, Daniel K; Fields, Henry W; Johnston, William M; Rosenstiel, Stephen F; Firestone, Allen R; Christensen, James C

    2010-12-01

    Although attractiveness and acceptability of orthodontic appliances have been rated by adults for themselves and for adolescents, children and adolescents have not provided any substantial data. The objective of this study was to evaluate preferences and acceptability of orthodontic appliances in children and adolescents. Images of orthodontic appliances previously captured and standardized were selected and incorporated into a computer-based survey. Additional images of shaped brackets and colored elastomeric ties, as well as discolored clear elastomeric ties, were captured and incorporated onto existing survey images with Photoshop (Adobe, San Jose, Calif). The survey displayed 12 orthodontic appliance variations to 139 children in 3 age groups: 9 to 11 years (n = 45), 12 to 14 years (n = 49), and 15 to 17 years (n = 45). The subjects rated each image for attractiveness and acceptability. All images were displayed and rated twice to assess rater reliability. Overall reliability ratings were r = 0.74 for attractiveness and k = 0.66 for acceptability. There were significant differences in bracket attractiveness and acceptability in each age group. The highest-rated appliances were clear aligners, twin brackets with colored ties, and shaped brackets with and without colored ties. Colored elastomeric ties improved attractiveness significantly over brackets without colored ties for children in the 12-to-14 year group. There was a tendency for older subjects to rate clear orthodontic appliances higher than did younger subjects. Ceramic brackets with discolored ties tended to be rated lower than ceramic brackets with new ties and scored lowest in acceptability and attractiveness in all age groups. Girls rated shaped brackets significantly higher than did boys. Children's preferences for orthodontic appliances differ by age and sex. Child and adolescent preferences differ from adult preferences. Copyright © 2010 American Association of Orthodontists. Published by Mosby

  11. PS wire chamber

    CERN Document Server

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  12. Pellet fired appliances. Market survey. 7. rev. ed.; Pelletheizungen. Marktuebersicht

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-01-15

    The market survey under consideration reports on pellet central heating systems and pellet fired appliances. The main chapters of this market survey are concerned to: (1) Information on wood pellets and pellet fired appliances; (2) Information about the interpretation of the market survey; (3) Survey of all compared pellet fired appliances with respect to the nominal power; (4) Price lists of pellet fired appliances and pellet central heating systems; (5) Type sheets of the compared pellet fired appliances and pellet central heating systems. Finally, this brochure contains the addresses of the produces and distribution partners of pellet fired appliances and pellet central heating systems.

  13. Skeletal class II malocclusion correction using the Bass appliance

    Directory of Open Access Journals (Sweden)

    Jigar Doshi

    2015-01-01

    Full Text Available Skeletal class II malocclusion is best treated by growth modification using the myofunctional appliances or the orthopedic appliances or the combination of the both depending upon the type of malocclusion encountered during the growth period of an individual. Though all myofunctional appliances work on the same principle with few basic differences; the orthodontist has to make a choice among the plethora of the appliances at his disposal. The present article is a case report of class II malocclusion treatment using the Bass appliance for the growth modification, which was followed by fixed appliance for the occlusal detailing.

  14. Magnetic anisotropy and anisotropic ballistic conductance of thin magnetic wires

    International Nuclear Information System (INIS)

    Sabirianov, R.

    2006-01-01

    The magnetocrystalline anisotropy of thin magnetic wires of iron and cobalt is quite different from the bulk phases. The spin moment of monatomic Fe wire may be as high as 3.4 μ B , while the orbital moment as high as 0.5 μ B . The magnetocrystalline anisotropy energy (MAE) was calculated for wires up to 0.6 nm in diameter starting from monatomic wire and adding consecutive shells for thicker wires. I observe that Fe wires exhibit the change sign with the stress applied along the wire. It means that easy axis may change from the direction along the wire to perpendicular to the wire. We find that ballistic conductance of the wire depends on the direction of the applied magnetic field, i.e. shows anisotropic ballistic magnetoresistance. This effect occurs due to the symmetry dependence of the splitting of degenerate bands in the applied field which changes the number of bands crossing the Fermi level. We find that the ballistic conductance changes with applied stress. Even for thicker wires the ballistic conductance changes by factor 2 on moderate tensile stain in our 5x4 model wire. Thus, the ballistic conductance of magnetic wires changes in the applied field due to the magnetostriction. This effect can be observed as large anisotropic BMR in the experiment

  15. Factors affecting dental biofilm in patients wearing fixed orthodontic appliances

    Directory of Open Access Journals (Sweden)

    Li Mei

    2017-01-01

    Full Text Available Abstract Background The aim of this study is to investigate the amount and the distribution of biofilm in patients wearing fixed appliances and its relation with age, gender, frequency of tooth brushing, and patient motivation. Methods The sample comprised 52 patients (15.5 ± 3.6 years old, 30 females and 22 males wearing fixed orthodontic appliances. Dental biofilm was assessed using a modified plaque index (PI. A questionnaire was used to collect patient’s information, including gender, age, treatment motivation, and frequency of tooth brushing. Results Gingival (PI score = 0.9 ± 0.7, mesial (0.8 ± 0.6, and distal (0.8 ± 0.5 areas accumulated more biofilm than occlusal areas (0.3 ± 0.3 (P < 0.038. The maxillary lateral incisors (1.1 ± 0.8 and maxillary canines (1.0 ± 0.8 had more biofilm than other teeth (P < 0.05. The maxillary arch (0.8 ± 0.7 had significantly more biofilm than mandibular arch (0.6 ± 0.6 (P = 0.042. No significant difference was found between the right side (0.7 ± 0.7 and left side (0.7 ± 0.6 (P = 0.627. Less biofilm was found in females (0.6 ± 0.5, adults (0.3 ± 0.3, and “self-motivated” patients (0.3 ± 0.3, compared with males (0.9 ± 0.5, children (0.8 ± 0.6, and “family-motivated” patients (1.1 ± 0.5 (P < 0.001. The amount of biofilm was associated with self-report of the frequency of daily tooth brushing (P < 0.001. Conclusions Patients wearing fixed orthodontic appliances have the highest biofilm accumulation on the maxillary lateral incisors and maxillary canines, particularly in the gingival area and areas behind arch wires. Less biofilm was observed in female and adult patients and in those who were self-motivated and brushed their teeth more often.

  16. Mechanical characterisation of orthodontic superelastic Ni-Ti wires

    Energy Technology Data Exchange (ETDEWEB)

    Arrigoni, M.; Pietrabissa, R. [Politecnico di Milano, Milano (Italy). Lab. of Biological Structure Mechanics; Auricchio, F.; Petrini, L. [Politecnico di Milano, Milano (Italy). Lab. of Biological Structure Mechanics; Pavia Univ. (Italy). Dept. of Structural Mechanics; Cacciafesta, V. [Politecnico di Milano, Milano (Italy). Lab. of Biological Structure Mechanics; Pavia Univ. (Italy). Dept. of Orthodontia

    2001-11-01

    Nowadays, the orthodontic treatment is improving thanks to the introduction of Ni-Ti super-elastic alloy wires in the ordinary therapy. Indeed, laboratory tests performed in the last decade have shown that Ni-Ti superelastic wires are able to satisfy the ideal requirements for fixed arch-wire appliance: high flexibility, minimal distortion or plastic deformation, light constant force production over a wide range of displacements. On the other hand, many orthodontic companies produce Ni-Ti arch-wires, without giving detailed specifications on their superelastic characteristics. To improve the knowledge on real properties for these products, an experimental campaign on different commercial arch-wires has been started at the Laboratory of Biological Structure Mechanics (LABS) at the Politecnico di Milano (Italy). This work presents the first step of the research, concerning the comparison between the behaviour of four types of wires (two produced by ORMCO and two produced by 3M/Unitek) under monotonic and cyclic isothermal tensile tests. The results show significant differences between the products in terms of elastic modulus, stress values of the loading-unloading plateau, hysteresis amplitude, spring-back capacity, shape recovery capability, strain rate effect and fatigue behaviour. (orig.)

  17. Advances in household appliances- A review

    International Nuclear Information System (INIS)

    Bansal, Pradeep; Vineyard, Edward; Abdelaziz, Omar

    2011-01-01

    An overview of options and potential barriers and risks for reducing the energy consumption, peak demand, and emissions for seven key energy consuming residential products (refrigerator-freezers, dishwashers, clothes washers, clothes dryers, electric ovens, gas ovens and microwave ovens) is presented. The paper primarily concentrates on the potential energy savings from the use of advanced technologies in appliances for the U.S. market. The significance and usefulness of each technology was evaluated in order to prioritize the R and D needs to improve energy efficiency of appliances in view of energy savings, cost, and complexity. The paper provides a snapshot of the future R and D needs for each of the technologies along with the associated barriers. Although significant energy savings may be achieved, one of the major barriers in most cases is high first cost. One way of addressing this issue and promoting the introduction of new technologies is to 'level' the playing field for all manufacturers by establishing Minimum Energy Performance Standards (MEPS) which are not cost prohibitive and promoting energy efficient products through incentives to both manufacturers and consumers. - Highlights: → This paper presents latest developments/status of advanced residential appliances. → Stringent minimum energy performance standards can reduce appliance energy use. → There is a potential to reduce energy use in appliances by up to 50%.

  18. Titanium orthodontic appliances for allergic patients.

    Science.gov (United States)

    Maspero, C; Giannini, L; Galbiati, G; Nolet, F; Esposito, L; Farronato, G

    2014-01-01

    The aim of our study was to assess the use of orthodontic appliances made in titanium for patients with an allergy to resin and nickel. We aim to highlight the resolution of problems such as stomatitis and peri-labial dermatitis, which generally manifest in patients who use traditional orthodontic appliances in acrylic resin and steel. A total of 120 patients of ages between ten and fifteen undergoing orthodontic treatment requiring a rapid palatal expander or a mobile appliance were evaluated and two patch sensitivity tests were done to assess the presence of allergies. The biocompatibility of a material is directly dependent on its corrosion effect. If a metal does not allow the release of ions it will not have a damaging action or cause destruction on the cellular DNA. The oxidation status of an ion is related to the reactivity of the ion itself and thus may give the latter a carcinogenic effect. Titanium appliances used for this study have obtained excellent results due to their ability to form superficial oxides, which block the oxidation phenomenon and thus corrosion. We have noticed a total regression of the symptoms after the use of titanium appliances in patients who had a sensitivity reaction.

  19. [Invisible and almost invisible orthodontic appliances].

    Science.gov (United States)

    Baron, Pascal

    2014-03-01

    Patient demand for invisible esthetic orthodontic appliances is steadily increasing. Two types of orthodontic appliances have a high rate of patient acceptance. The lingual technique has continually evolved by offering both prefabricated brackets or custom-made brackets. The various techniques have been improved over time, and the results are better than ever. Thermoplastic aligners are an alternative to lingual devices and their use is rapidly growing. Their specific properties make it easier to assess their indications and limitations. A review of the literature, the development of these systems and a presentation of some clinical examples of treated cases will help us to provide some of the basics for understanding each of these two types of appliances and to demonstrate the advantages and disadvantages of each system. © EDP Sciences, SFODF, 2014.

  20. Scheduling home appliances for energy efficient buildings

    DEFF Research Database (Denmark)

    Rossello Busquet, Ana; Kardaras, Georgios; Iversen, Villy Bæk

    2010-01-01

    appliances is proposed and analyzed. The main concept behind this approach is the aggregation of home appliances into priority classes and the definition of a maximum power consumption threshold, which is not allowed to be exceeded during peak hours. The scenario simulated describes a modern household, where...... the electrical devices are classified into low and high priority groups. The high priority devices are always granted power in order to operate normally. On the contrary, the low priority devices are granted or denied access to electrical power according to; their energy consumption and the available margin....... This can become beneficial for both energy companies and users. The electricity suppliers companies will be capable of regulating power generation during demand peaks. Moreover, users can be granted lower electricity bill rates for accepting delaying the operation of some of their appliances. To analyze...

  1. Arch development with trans-force lingual appliances.

    Science.gov (United States)

    Clark, William J

    2005-01-01

    Trans-Force lingual appliances are designed to correct arch form in patients with contracted dental arches. Interceptive treatment with this new series of pre-activated lingual appliances offers new possibilities for arch development, in combination with fixed appliances. Palatal and lingual appliances insert in horizontal lingual sheaths in molar bands. No activation is required after the appliance is fitted, and this principle is extended to a series of appliances for sagittal and transverse arch development. Both sagittal and transverse appliances have additional components to achieve 3-way expansion where this is indicated. The invisible lingual appliances may be used in correction of all classes of malocclusion at any stage of development, from mixed dentition through permanent dentition, and this approach has wide indications in adult treatment.

  2. Towards plant wires

    OpenAIRE

    Adamatzky, Andrew

    2014-01-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self...

  3. A Study on Home Appliance Recycling Law of Japan

    OpenAIRE

    許, 楊; Yang, XU

    2011-01-01

    The establishment of the recycling based society which reconciles the economy and the environment has received significant attention.The study focuses on the home appliance recycling law. Some used home appliances are treated legally, others are exported illegally. Therefore this paper clarifies the results of the application of the home appliance recycling law and tries to present elemental conditions to create the global recycling system of used home appliances.

  4. Skeletal class II malocclusion correction using the Bass appliance

    OpenAIRE

    Jigar Doshi; Tarulatha Revanappa Shyagali; Kalyani M Trivedi

    2015-01-01

    Skeletal class II malocclusion is best treated by growth modification using the myofunctional appliances or the orthopedic appliances or the combination of the both depending upon the type of malocclusion encountered during the growth period of an individual. Though all myofunctional appliances work on the same principle with few basic differences; the orthodontist has to make a choice among the plethora of the appliances at his disposal. The present article is a case report of class II maloc...

  5. Investigation of wire motion in superconducting magnets

    International Nuclear Information System (INIS)

    Ogitsu, T.; Tsuchiya, K.; Devred, A.

    1990-09-01

    The large Lorentz forces occuring during the excitation of superconducting magnets can provoke sudden motions of wire, which eventually release enough energy to trigger a quench. These wire motions are accompanied by two electromagnetic effects: an induced emf along the moved wire, and a local change in flux caused by the minute dislocation of current. Both effects cause spikes in the coil voltage. Voltage data recorded during the excitation of a superconducting quadrupole magnet which early exhibit such events are here reported. Interpretations of the voltage spikes in terms of energy release are also presented, leading to insights on the spectrum of the disturbances which occur in real magnets. 15 refs

  6. Non-intrusive appliance load monitoring system based on a modern kWh-meter

    Energy Technology Data Exchange (ETDEWEB)

    Pihala, H. [VTT Energy, Espoo (Finland). Energy Systems

    1998-12-01

    Non-intrusive appliance load monitoring (NIALM) is a fairly new method to estimate load profiles of individual electric appliances in a small building, like a household, by monitoring the whole load at a single point with one recording device without sub-meters. Appliances have special electrical characteristics, the positive and negative active and reactive power changes during the time they are switched on or off. These changes are called events and are detected with a monitoring device called an event recorder. Different NIALM-concepts developed in Europe and in the United States are generally discussed. The NIALM-concept developed in this study is based on a 3-phase, power quality monitoring kWh-meter and unique load identification algorithms. This modern kWh-meter with a serial data bus to a laptop personal computer is used as die event recorder. The NIALM-concept of this presentation shows for the first time how a kWh-meter can be used at the same time for billing, power quality and appliance end-use monitoring. An essential part of the developed NIALM-system prototype is the software of load identification algorithms which runs in an off-line personal computer. These algorithms are able to identify, with a certain accuracy, both two-state and multi-state appliances. This prototype requires manual-setup in which the naming of appliances is performed. The results of the prototype NIALMS were verified in a large, single family detached house and they were compared to the results of other prototypes in France and the United States, although this comparison is difficult because of different supply systems, appliance stock and number of tested sites. Different applications of NIALM are discussed. Gathering of load research data, verification of DSM-programs, home automation, failure analysis of appliances and security surveillance of buildings are interesting areas of NIALM. Both utilities and customers can benefit from these applications. It is possible to

  7. Photovoltaic Wire, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  8. Photovoltaic Wire Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  9. Charpak hemispherical wire chamber

    CERN Document Server

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  10. ELECTRICAL APPLIANCE SERVICEMAN, SUGGESTED GUIDE FOR A TRAINING COURSE.

    Science.gov (United States)

    LOVE, L. CARL; RONEY, MAURICE W.

    THE PURPOSE OF THIS GUIDE IS TO AID IN PLANNING AND DEVELOPING A COURSE FOR TRAINING ELECTRICAL APPLIANCE SERVICEMEN. OUTLINES (ONE PAGE EACH) COVER -- (1) RELATED INSTRUCTION, (2) FUNDAMENTALS OF ELECTRICITY, (3) BASIC CONTROLS AND ELECTRONIC COMPONENTS, (4) RESISTANCE HEATING APPLIANCES, (5) MOTORS FOR ELECTRIC APPLIANCES, (6) MOTOR DRIVEN…

  11. 21 CFR 872.5410 - Orthodontic appliance and accessories.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Orthodontic appliance and accessories. 872.5410... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Therapeutic Devices § 872.5410 Orthodontic appliance and accessories. (a) Identification. An orthodontic appliance and accessories is a device intended for use in...

  12. 1998 wire development workshop proceedings

    International Nuclear Information System (INIS)

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development

  13. Efficacy of modified pendulum appliance for the correction of class II malocclusion: A clinical study

    Directory of Open Access Journals (Sweden)

    Monika Koul

    2017-01-01

    Full Text Available Introduction: The purpose of this prospective study was to analyze the efficiency of pendulum appliance for distalizing maxillary first molar while decreasing the anchorage loss by banding first and second premolar and making them one unit. Materials and Methods: The study group comprised of 20 patients (mean age 13 ± 2 years who had skeletal Class I and Angle's Class II molar relation. Modified pendulum appliance was given to distalize maxillary first molar and to decrease the anchorage loss both first and second premolars were banded as a single unit by soldering a 19-gauge stainless steel wire. Then both skeletal and dental changes were measured on the pretreatment and posttreatment lateral cephalograms. Results: The maxillary molar was distalized, and a Class I molar relation was achieved in 3 ± 2 months. Maxillary first molar distalized by 4.48 mm in the region of dental crown by tipping distally an average of 8.5°. Both the premolars tipped distally significantly. Thus, by this modification, the anchor loss was minimized. Conclusion: It was concluded that the efficiency of pendulum appliance was increased by this modification, as the anchorage was increased, the space loss was minimized.

  14. Printable Nano-Field Effect Transistors Combined with Carbon Nanotube Based Printable Interconnect Wires for Large-Area Deployable Active Phased-Array, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Flexible electronic circuits can be easily integrated with large area (>10m aperture), inflatable antennas to provide distributed control and processing...

  15. Clinical evolution of the Invisalign appliance.

    Science.gov (United States)

    Vlaskalic, Vicki; Boyd, Robert L

    2002-10-01

    The Invisalign System of tooth movement has been available to orthodontists since 1999 and has now become available to the entire dental profession. This paper explores the role of this system within the dental armamentarium and describes the clinical evolution of the appliance, based on a feasibility study initiated at the University of the Pacific in 1997.

  16. Appliance Services. Basic Course. Career Education.

    Science.gov (United States)

    Killough, Joseph

    Several intermediate performance objectives and corresponding criterion measures are listed for each of 25 terminal objectives for a basic appliance repair course. The materials were developed for a 36-week course (2 hours daily) designed to enable the student to be well-grounded in the fundamentals of electricity as well as applied electricity.…

  17. Mandibular advancement appliance for obstructive sleep apnoea

    DEFF Research Database (Denmark)

    Petri, Niels; Svanholt, Palle; Solow, Beni

    2008-01-01

    The aim of this trial was to evaluate the efficacy of a mandibular advancement appliance (MAA) for obstructive sleep apnoea (OSA). Ninety-three patients with OSA and a mean apnoea-hypopnoea index (AHI) of 34.7 were centrally randomised into three, parallel groups: (a) MAA; (b) mandibular non...

  18. Management of overbite with the Invisalign appliance.

    Science.gov (United States)

    Khosravi, Roozbeh; Cohanim, Bobby; Hujoel, Philippe; Daher, Sam; Neal, Michelle; Liu, Weitao; Huang, Greg

    2017-04-01

    Most of the published literature on the management of overbite with the Invisalign appliance (Align Technology, Santa Clara, Calif) consists of case reports and case series. In this retrospective study of 120 patients, we sought to assess the nature of overbite changes with the Invisalign appliance. Records were collected from 3 practitioners, all experienced with the Invisalign technique. The patients were consecutively treated adults (>18 years old) who underwent orthodontic treatment only with the Invisalign appliance. Patients with major transverse or anteroposterior changes or extraction treatment plans were excluded. The study sample included 68 patients with normal overbites, 40 with deepbites, and 12 with open bites. Their median age was 33 years, and 70% of the patients were women. Cephalometric analyses indicated that the deepbite patients had a median overbite opening of 1.5 mm, whereas the open bite patients had a median deepening of 1.5 mm. The median change for the normal overbite patients was 0.3 mm. Changes in incisor position were responsible for most of the improvements in the deepbite and open bite groups. Minimal changes in molar vertical position and mandibular plane angle were noted. The Invisalign appliance appears to manage the vertical dimension relatively well, and the primary mechanism is via incisor movements. Published by Elsevier Inc.

  19. Induced magnetic moment in stainless steel components of orthodontic appliances in 1.5 T MRI scanners

    Science.gov (United States)

    Rollins, Nancy K.; Liang, Hui; Park, Yong Jong

    2015-01-01

    Purpose: Most orthodontic appliances are made of stainless steel materials and induce severe magnetic susceptibility artifacts in brain MRI. In an effort for correcting these artifacts, it is important to know the value of induced magnetic moments in all parts of orthodontic appliances. In this study, the induced magnetic moment of stainless steel orthodontic brackets, molar bands, and arch-wires from several vendors is measured. Methods: Individual stainless steel brackets, molar bands, and short segments of arch-wire were positioned in the center of spherical flask filled with water through a thin plastic rod. The induced magnetic moment at 1.5 T was determined by fitting the B0 map to the z-component of the magnetic dipole field using a computer routine. Results: The induced magnetic moment at 1.5 T was dominated by the longitudinal component mz, with a small contribution from the transverse components. The mz was insensitive to the orientation of the metal parts. The orthodontic brackets collectively dominated the magnetic dipole moment in orthodontic appliances. In brackets from six vendors, the total induced mz from 20 brackets for nonmolar teeth ranged from 0.108 to 0.158 (median 0.122) A ⋅ m2. The mz in eight molar bands with bracket attachment from two vendors ranged from 0.0004 to 0.0166 (median 0.0035) A ⋅ m2. Several full length arch wires had induced magnetic moment in the range of 0.006–0.025 (median 0.015) A ⋅ m2. Conclusions: Orthodontic brackets collectively contributed most to the total magnetic moment. Different types of brackets, molar bands, and arch wires all exhibit substantial variability in the induced magnetic moment. PMID:26429261

  20. Automating wiring formboard design

    NARCIS (Netherlands)

    Van den Berg, T.

    2013-01-01

    Increase in aircraft wiring complexity call for manufacturing design improvements to reduce cost and lead-time. To achieve such improvements, a joint research project was performed by the Flight Performance and Propulsion (FPP) group and Fokker Elmo BV, the second largest aircraft wiring harness

  1. Wear of dragline wire ropes

    Energy Technology Data Exchange (ETDEWEB)

    Dayawansa, D.; Kuruppu, M.; Mashiri, F.; Bartosiewicz, H. [Monash University (Caulfield Campus), Caulfield East, Vic. (Australia). Department of Mechanical Engineering,

    2005-07-01

    Wire ropes are one of the most heavily used components in a dragline. Hoist ropes are subjected to fatigue due to the cyclic nature of load handling as well as due to rope bending over the sheaves and the drum under load. This leads to wire breaks due to fatigue. Accumulation of a number of wire breaks close to each other can have a detrimental effect on the rope. Furthermore, to allow for the increasing demand for higher load capacity coupled with the inconvenience of having very large ropes, the factor of safety is often compromised, which increases the wear rate. Drag ropes are also subjected to heavy loads. More importantly, they are allowed to drag along the rough mine surface subjecting them to external physical abrasion. This makes the life of drag ropes one of the lowest among those used in a dragline. Suspension and IBS ropes are relatively uniformly loaded during their regular usage although they need to withstand dynamic load cycles as well as bending. Hence they tend to last for a number of years on average. The paper analyses the wear types and their severity of each of these rope applications, and suggests methods to determine rope wear rates and the resulting rope life. The paper further gives suggestions for good operating and maintenance practice that can extend the rope life and help reduce the large expenditure associated with every major rope change in a dragline. 6 refs., 8 figs., 1 tab.

  2. Release of nickel and chromium ions in the saliva of patients with fixed orthodontic appliance: An in-vivo study.

    Science.gov (United States)

    Dwivedi, Anoop; Tikku, Tripti; Khanna, Rohit; Maurya, Rana Pratap; Verma, Geeta; Murthy, R C

    2015-01-01

    Various components of fixed orthodontic appliances are continuously interacting with saliva and other fluids in the mouth releasing various metal ions including nickel and chromium that can cause damaging effects if their concentration exceeds above the toxic dose. To determine and compare the level of nickel and chromium in the saliva of patients undergoing fixed orthodontic treatment at different time periods. The sample of saliva of 13 patients was taken at different time periods that is: Group 1 (before appliance placement), Group II, III, and IV (after 1-week, 1-month, and 3 months of appliance placement respectively). The fixed appliance comprised of brackets, bands, buccal tubes, lingual sheath, transpalatal arch and wires composed of Ni-Ti and stainless steel. The level of ions was determined using graphite furnace atomic absorption spectro-photometry. The data thus obtained were statistically analyzed using SPSS Statistical Analysis Software (Version 15.0). Level of nickel and chromium in saliva was highest in Group II and lowest in Groups I for both the ions. On comparison among different Groups, it was statistically significant for all the groups (<0.001) except between Group III and Group IV. The release of nickel and chromium was maximum at 1-week and then the level gradually declined. These values were well below the toxic dose of these ions. The results should be viewed with caution in subjects with Ni hypersensitivity.

  3. Slice of LHC dipole wiring

    CERN Multimedia

    Dipole model slice made in 1994 by Ansaldo. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. 50’000 tonnes of steel sheets are used to make the magnet yokes that keep the wiring firmly in place. The yokes constitute approximately 80% of the accelerator's weight and, placed side by side, stretch over 20 km!

  4. Modeling of GE Appliances in GridLAB-D: Peak Demand Reduction

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, Jason C.; Vyakaranam, Bharat GNVSR; Prakash Kumar, Nirupama; Leistritz, Sean M.; Parker, Graham B.

    2012-04-29

    The widespread adoption of demand response enabled appliances and thermostats can result in significant reduction to peak electrical demand and provide potential grid stabilization benefits. GE has developed a line of appliances that will have the capability of offering several levels of demand reduction actions based on information from the utility grid, often in the form of price. However due to a number of factors, including the number of demand response enabled appliances available at any given time, the reduction of diversity factor due to the synchronizing control signal, and the percentage of consumers who may override the utility signal, it can be difficult to predict the aggregate response of a large number of residences. The effects of these behaviors can be modeled and simulated in open-source software, GridLAB-D, including evaluation of appliance controls, improvement to current algorithms, and development of aggregate control methodologies. This report is the first in a series of three reports describing the potential of GE's demand response enabled appliances to provide benefits to the utility grid. The first report will describe the modeling methodology used to represent the GE appliances in the GridLAB-D simulation environment and the estimated potential for peak demand reduction at various deployment levels. The second and third reports will explore the potential of aggregated group actions to positively impact grid stability, including frequency and voltage regulation and spinning reserves, and the impacts on distribution feeder voltage regulation, including mitigation of fluctuations caused by high penetration of photovoltaic distributed generation and the effects on volt-var control schemes.

  5. Thermosonic wire bonding of IC devices using palladium wire

    International Nuclear Information System (INIS)

    Shze, J.H.; Poh, M.T.; Tan, R.M.

    1996-01-01

    The feasibility of replacing gold wire by palladium wire in thermosonic wire bonding of CMOS and bipolar devices are studied in terms of the manufacturability, physical, electrical and assembly performance. The results that palladium wire is a viable option for bonding the bipolar devices but not the CMOS devices

  6. Towards plant wires.

    Science.gov (United States)

    Adamatzky, Andrew

    2014-08-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self-growing wetware circuits and devices, and integration of plant-based electronic components into future and emergent bio-hybrid systems. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  7. [Appliance of viscosupplementation in osteoarthritis treatment].

    Science.gov (United States)

    Vlak, Tonko; Jungić, Aleksandra

    2006-01-01

    Viscosupplementation or intraarticular appliance of hyaluronic acid is one of the methods in the treatment of patients with OA. Application is indicated in OA grade I-III according to Kellgren. Medical devices of hyaluronic acid, present on Croatian market, are produced by extraction from rooster combs or by biofermentation from nonpathogenic streptococcus strains. Boifermentative production excludes present of animal origin proteins and prions in medical device, same as possibility of unwanted alergic reactions appearance. Numerous researches have proved that this kind of treatment is safe, effective, well tolerated and it can be repeated if needed. Alleviation of the symptoms is proved up to one year after the last i.a. injection of hyaluronic acid. Appliance of viscosupplementation significantly slows down progression of OA and more invasive treatment methods are usually prolonged or delayed.

  8. Oral appliances and functional orthopaedic appliances for obstructive sleep apnoea in children.

    Science.gov (United States)

    Carvalho, F R; Lentini-Oliveira, D; Machado, M A C; Prado, G F; Prado, L B F; Saconato, H

    2007-04-18

    Apnoea is a breathing disorder marked by the absence of airflow at the nose or mouth. In children, risk factors include adenotonsillar hypertrophy, obesity, neuromuscular disorders and craniofacial anomalies. The most common treatment for obstructive sleep apnoea syndrome (OSAS) in childhood is adenotonsillectomy. This approach is limited by its surgical risks, mostly in children with comorbities and, in some patients, by recurrence that can be associated with craniofacial problems. Oral appliances and functional orthopaedic appliances have been used for patients who have OSAS and craniofacial anomalies because they change the mandible posture forwards and potentially enlarge the upper airway and increase the upper airspace, improving the respiratory function. To assess the effectiveness of oral appliances or functional orthopaedic appliances for OSAS in children. A sensitive search was developed for the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2005, Issue 3); PubMed (January 1966 to September 2005); EMBASE (1980 to September 2005); Lilacs (1982 to September 2005); BBO-Bibliografia Brasileira de Odontologia (1986 to September 2005); and SciELO (1997 to September 2005). There was no restriction of language or source of information. All randomised or quasi-randomised controlled trials comparing all types of oral and functional orthopaedic appliances with placebo or no treatment, in children 15 years old or younger. reduction of apnoea to less than one episode per hour. dental and skeletal relationship, sleep parameters improvement, cognitive and phonoaudiologic function, behavioural problems, drop outs and withdrawals, quality of life, side effects (tolerability), economic evaluation. Data were independently extracted by two review authors. Authors were contacted for additional information. Risk ratios with 95% confidence intervals were calculated for all important dichotomous outcomes. The initial search identified 384 trials

  9. Catalytic combustion in small wood burning appliances

    Energy Technology Data Exchange (ETDEWEB)

    Oravainen, H. [VTT Energy, Jyvaeskylae (Finland)

    1996-12-31

    There is over a million hand fired small heating appliances in Finland where about 5,4 million cubic meters of wood fuel is used. Combustion in such heating appliances is a batch-type process. In early stages of combustion when volatiles are burned, the formation of carbon monoxide (CO) and other combustible gases are difficult to avoid when using fuels that have high volatile matter content. Harmful emissions are formed mostly after each fuel adding but also during char burnout period. When the CO-content in flue gases is, say over 0.5 %, also other harmful emissions will be formed. Methane (CH{sub 4}) and other hydrocarbons are released and the amount of polycyclic aromatic hydrocarbons (PAH)-compounds can be remarkable. Some PAH-compounds are very carcinogenic. It has been estimated that in Finland even more than 90 % of hydrocarbon and PAH emissions are due to small scale wood combustion. Emissions from transportation is excluded from these figures. That is why wood combustion has a net effect on greenhouse gas phenomena. For example carbon monoxide emissions from small scale wood combustion are two fold compared to that of energy production in power plants. Methane emission is of the same order as emission from transportation and seven fold compared with those of energy production. Emissions from small heating appliances can be reduced by developing the combustion techniques, but also by using other means, for example catalytic converters. In certain stages of the batch combustion, temperature is not high enough, gas mixing is not good enough and residence time is too short for complete combustion. When placed to a suitable place inside a heating appliance, a catalytic converter can oxidize unburned gases in the flue gas into compounds that are not harmful to the environment. (3 refs.)

  10. Switch green : Energy Star appliance feebate

    International Nuclear Information System (INIS)

    2007-01-01

    Between 1990 and 2004, greenhouse gas (GHG) emissions from the residential sector have grown by 10 per cent, and are likely to continue growing unless a policy aimed at reducing emissions is introduced. The residential sector is a significant contributor to Canada's overall GHG emissions, and an important source for potential reductions. This report presented the results of a study that described and evaluated a new economic instrument aimed at reducing greenhouse gas (GHG) emissions and energy consumption in Canada from household appliances, such as air conditioners, furnaces and boilers. Results of a quantitative analysis to determine the effect of changing taxation of residential appliances to reflect energy consumption and greenhouse gas emissions were presented. In addition, the report presented the results of a qualitative evaluation of the policy, using the criteria established in the 2005 budget plan, a framework for evaluating environmental tax proposals. The report outlined the context for the tax proposal that was evaluated and provided a summary of trends in Canada's greenhouse gas emissions and energy consumption as well as a discussion of important trends in residential energy consumption. A review of policies already in place to address energy consumption from household appliances was also presented. 11 tabs., 6 figs

  11. Initial arch wires for alignment of crooked teeth with fixed orthodontic braces.

    Science.gov (United States)

    Wang, Yan; Jian, Fan; Lai, Wenli; Zhao, Zhihe; Yang, Zhi; Liao, Zhengyu; Shi, Zongdao; Wu, Taixiang; Millett, Declan T; McIntyre, Grant T; Hickman, Joy

    2010-04-14

    The initial arch wire is the first arch wire to be inserted into the fixed appliance at the beginning of orthodontic treatment and is used mainly for correcting crowding and rotations of teeth. With a number of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. To identify and assess the evidence for the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (30th November 2009), CENTRAL (The Cochrane Library 2009, Issue 4), MEDLINE (1950 to 30th November 2009) and EMBASE (1980 to 30th November 2009). Reference lists of articles were also searched. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies. Randomised controlled trials (RCTs) of initial arch wires to align crooked teeth with fixed orthodontic braces were selected. Only studies involving patients with upper and/or lower full arch fixed orthodontic appliances were included. Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information. Seven RCTs, with 517 participants, provided data for this review. Among them, five trials investigated the speed of initial tooth alignment comparing: 0.016 inch ion-implanted A-NiTi wire versus 0.016 inch A-NiTi versus 0.0175 multistrand stainless steel wire; 0.016x0.022 inch medium force active M-NiTi wire versus 0.016x0.022 inch graded force active M-NiTi wire versus 0.0155 inch multistrand

  12. Signal Acquisition and Processing in the Magnetic Defectoscopy of Steel Wire Ropes

    Directory of Open Access Journals (Sweden)

    N. S. Jovičić

    2012-11-01

    Full Text Available The system that resolves the problem of wire rope defects using a magnetic method of inspection is presented in this paper. Implementation of the system should provide for full monitoring of wire rope condition, according to the prescribed international standards. The purpose of this system, in addition to identifying defects in the rope, is to determine to what extent damage has been done. The measurement procedure provides for a better understanding of the defects that occur, as well as the rejection criteria of used ropes, that way increasing their security. Hardware and software design of appliance for recording defects and test results are presented in this paper.

  13. Cryogenic Pressure Seal for Wires

    Science.gov (United States)

    Ciana, J. J.

    1984-01-01

    High-pressure-seal formed by forcing polyurethane into space surrounding wire or cable in special fitting. Wire or cable routed through fitting then through a tightly fitting cap. Wire insulation left intact. Cap filled with sealant and forced onto the fitting: this pushes sealant into fitting so it seals wire or cable in fitting as well as in cap.

  14. Pin Wire Coating Trip Report

    International Nuclear Information System (INIS)

    Spellman, G P

    2004-01-01

    A meeting to discuss the current pin wire coating problems was held at the Reynolds plant in Los Angeles on 2MAR04. The attendance list for Reynolds personnel is attached. there was an initial presentation which gave a brief history and the current status of pin wire coating at Reynolds. There was a presentation by Lori Primus on the requirements and issues for the coating. There was a presentation by Jim Smith of LANL on the chemistry and to some extent process development done to date. There was a long session covering what steps should be taken in the short term and, to a lesser extent, the long term. The coating currently being used is a blend of two polymers, polyethersulfone and polyparabanic acid (PPA) and some TiO2 filler. This system was accepted and put into production when the pin wire coating was outsourced to another company in 1974. When that company no longer was interested, the wire coating was brought in-house to Reynolds. At that time polyparabanic acid was actually a commercial product available from Exxon under the trade name Tradlon. However, it appears that the material used at Reynolds was synthesized locally. Also, it appears that a single large batch was synthesized in that time period and used up to 1997 when the supply ran out. The reason for the inclusion of TiO2 is not known although it does act as a rheological thickener. However, a more controlled thickening can be obtained with materials such as fumed silica. This material would have less likelihood of causing point imperfections in the coatings. Also, the mixing technique being used for all stages of the process is a relatively low shear ball mill process and the author recommends a high shear process such as a three roll paint mill, at least for the final mixing. Since solvent is added to the powder at Reynolds, it may be that they need to have the paint mill there

  15. Si Wire-Array Solar Cells

    Science.gov (United States)

    Boettcher, Shannon

    2010-03-01

    Micron-scale Si wire arrays are three-dimensional photovoltaic absorbers that enable orthogonalization of light absorption and carrier collection and hence allow for the utilization of relatively impure Si in efficient solar cell designs. The wire arrays are grown by a vapor-liquid-solid-catalyzed process on a crystalline (111) Si wafer lithographically patterned with an array of metal catalyst particles. Following growth, such arrays can be embedded in polymethyldisiloxane (PDMS) and then peeled from the template growth substrate. The result is an unusual photovoltaic material: a flexible, bendable, wafer-thickness crystalline Si absorber. In this paper I will describe: 1. the growth of high-quality Si wires with controllable doping and the evaluation of their photovoltaic energy-conversion performance using a test electrolyte that forms a rectifying conformal semiconductor-liquid contact 2. the observation of enhanced absorption in wire arrays exceeding the conventional light trapping limits for planar Si cells of equivalent material thickness and 3. single-wire and large-area solid-state Si wire-array solar cell results obtained to date with directions for future cell designs based on optical and device physics. In collaboration with Michael Kelzenberg, Morgan Putnam, Joshua Spurgeon, Daniel Turner-Evans, Emily Warren, Nathan Lewis, and Harry Atwater, California Institute of Technology.

  16. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  17. Measure Guideline: Combustion Safety for Natural Draft Appliances Through Appliance Zone Isolation

    Energy Technology Data Exchange (ETDEWEB)

    Fitzgerald, J. [Center for Energy and Environment, Minneapolis, MN (United States); Bohac, D. [Center for Energy and Environment, Minneapolis, MN (United States)

    2014-04-01

    This measure guideline covers how to assess and carry out the isolation of natural draft combustion appliances from the conditioned space of low-rise residential buildings. It deals with combustion appliances located either within the living space in enclosed closets or side rooms or outside the living space in an adjacent area like an attic or garage. This subset of houses does not require comprehensive combustion safety tests and simplified prescriptive procedures can be used to address safety concerns. This allows residential energy retrofit contractors inexperienced in advanced combustion safety testing to effectively address combustion safety issues and allow energy retrofits including tightening and changes to distribution and ventilation systems to proceed.

  18. Applications of surface analysis in the wire industry

    Science.gov (United States)

    Stout, David A.

    The quality of wire is judged not only by its physical properties such as tensile strength and fatigue resistance, but also by its surface finish. The surface roughness, oxide formation, cleanliness, and plating homogeneity and porosity are just a few of the surface properties than can influence the performance of a wire product. Coupled to this is the large amount of surface area generated in drawing wire. For example, a ten pound spool holds nine miles of 0.006″ diameter stainless steel wire. For these reasons surface analysis has become important both to the manufacturer and consumer of wire products. When surface analysis equipment such as AES, ESCA, and SIMS was first becoming commercially available in the late sixties and early seventies, the wire industry was beginning to enter a phase of technological development for many of its products. Wire manufacturers and users began using surface analysis to investigate such topics as adhesion of brass plated automobile tire cord to rubber and diffusion of layered deposits. Examples of surface analysis used for process control, problem solving, and project development include discoloration problems on stainless steel wire, welding problems with composite wires, diffusion formed brass coatings, and diffusion problems with solder coated and Cu plated steel wire.

  19. A new design of wire locators for drift tubes

    CERN Document Server

    Ilgner, C

    2004-01-01

    Every position-sensitive wire detector needs to solve the problem of wire positioning with a defined accuracy all over its sensitive volume. In particular, thin-walled drift tubes ("straws"), which are currently being attached to large detector units of several tens of square meters of surface, need to be equipped with wire locators along their signal wires. A wire locator has been developed together with an insertion device, especially for medium-sized drift tube systems, which significantly reduces the production time and avoids the danger of applying epoxy glue to the signal wire. The wire locator is being inserted in one single time-saving production step together with the signal wire itself. The proposed design is being compared to the rigid wire locators in use in the COMPASS straw tracking system at CERN. The investigation comprises both wire- centering capability and influence on the efficiency of adjacent detector regions, demonstrating the competitive performance of the proposed new system. Its suff...

  20. FIXED OR REMOVABLE APPLIANCE FOR EARLY ORTHODONTIC TREATMENT OF FUNCTIONAL ANTERIOR CROSSBITE.

    Science.gov (United States)

    Wiedel, Anna-Paulina

    2015-01-01

    angle > 0 degrees, and no previous orthodontic treatment. Sixty-two patients agreed to participate and were randomly allocated for treatment either with FA with brackets and wires, or RA, comprising acrylic plates with protruding springs. Paper I compared and evaluated the efficiency of the two different treatment strategies to correct the anterior crossbite with anterior shift in mixed dentition. Paper II compared and evaluated the stability of the results of the two treatment methods two years after the appliances were removed. In Paper III, the cost-effectiveness of the two treatment methods was compared and evaluated by cost-minimization analysis. Paper IV evaluated and compared the patient's perceptions of the two treatment methods, in terms of perceived pain, discomfort and impairment of jaw function. The following conclusions were drawn from the results: Paper I. Anterior crossbite with functional shift in the mixed dentition can be successfully corrected by either fixed or removable appliance therapy in a short-term perspective. Treatment time for correction of anterior crossbite with functional shift was significantly shorter for FA compared to RA but the difference had minor clinical relevance. Paper II. In the mixed dentition, anterior crossbite affecting one or more incisors can be successfully corrected by either fixed or removable appliances, with similarly stable outcomes and equally favourable prognoses. Either type of appliance can be recommended. Paper III. Correction of anterior crossbite with functional shift using fixed appliance offers significant economic benefits over removable appliances, including lower direct costs for materials and lower indirect costs. Even when only successful outcomes are considered, treatment with removable appliance is more expensive. Paper IV. The general levels of pain intensity and discomfort were low to moderate in both groups. The level of pain and discomfort intensity was higher for the first three days in the

  1. Fabrication of lingual orthodontic appliances: past, present and future.

    Science.gov (United States)

    Hutchinson, Ian; Lee, Jang Yeol

    2013-09-01

    Lingual orthodontics is increasing in popularity, with more adults receiving orthodontic treatment and opting for truly invisible appliances that do not have any limitations on the type of tooth movement they can achieve. In addition, there are a growing number of children receiving lingual appliances as they have been shown to significantly reduce the incidence of decalcification. Combining this growth in popularity with advances in computer technology, it is possible to treatment plan, design the appliance and have it custom made all with the click of a button. This article highlights the different methods that have been utilized in the fabrication of lingual appliances.

  2. Magnetic fields from electric toothbrushes promote corrosion in orthodontic stainless steel appliances but not in titanium appliances.

    Science.gov (United States)

    Kameda, Takashi; Ohkuma, Kazuo; Oda, Hirotake; Sano, Natsuki; Batbayar, Nomintsetseg; Terashima, Yukari; Sato, Soh; Terada, Kazuto

    2013-01-01

    Electric toothbrushes are widely used, and their electric motors have been reported to produce low-frequency electromagnetic fields that induced electric currents in metallic objects worn by the users. In this study, we showed that electric toothbrushes generated low-frequency magnetic fields (MFs) and induced electric currents in orthodontic appliances in artificial saliva (AS), which accelerated corrosion in stainless steel (SUS) appliances, but not in titanium (Ti) appliances; the corrosion was evaluated by using an inductively coupled plasma-optical emission spectrometer and a three-dimensional laser confocal microscope. The pH of AS used for appliance immersion did not change during or after MF exposure. These results suggested that MF-induced currents from electric toothbrushes could erode SUS appliances, but not Ti appliances, because of their high corrosion potentials. Further studies are required to clarify the mechanisms of metallic corrosion by induced currents in dental fields, which may trigger metal allergies in patients.

  3. A comparative study of bio degradation of various orthodontic arch wires: an in vitro study.

    Science.gov (United States)

    Gopikrishnan, S; Melath, Anil; Ajith, V V; Mathews, N Binoy

    2015-01-01

    Orthodontic wires are the corner stones of the science and art of orthodontics and they remain in the patient's mouth for a prolonged period of 18-24 months. It is but natural to expect that they will undergo some biodegradation when in the oral environment during that period. This study aims to compare the biodegradation characteristics of four different orthodontic wires, stainless steel, nickel titanium (NiTi), titanium molybdenum alloy (TMA), and copper NiTi and to assess whether these biodegradation products, are within acceptable limits. This study involved the incubation of four different wires in artificial saliva and analyzing the amount of metal released from them at the end of a 28 days study period. The metals analyzed for where nickel, chromium, copper, cobalt, manganese, iron, molybdenum, and titanium. The artificial saliva was changed on days 7, 14, and 21 to prevent the saturation of metals in the artificial saliva. At the end of 28 days, these four samples of artificial saliva of each wire were mixed together and analyzed for the eight metals using an inductively coupled plasma spectroscope. The results showed only the release of nickel, chromium, and iron from stainless steel wire, nickel from NiTi wire, nickel, and chromium from copper NiTi and none from TMA wire. The metals released from arch wires are of such minute quantities to be of any biologic hazard. The amount of metals released is well within acceptable biocompatible limits. Though this study has analyzed the biodegradation of various orthodontic wires, orthodontic wires are never used alone in mechanotherapy. Orthodontic wires along with multiband appliance system with which it is always used and in combination with accessories like face bows may release more metals.

  4. Research on quantum efficiency of GaN wire photocathode

    Science.gov (United States)

    Xia, Sihao; Liu, Lei; Diao, Yu; Kong, Yike

    2017-02-01

    On the basis of three-dimensional continuity equation in semiconductors and finite difference method, the carrier concentration and the quantum efficiency of GaN wire photocathode as a function of incident photon energy are achieved. Results show that the quantum efficiency of the wire photocathode is largely enhanced compared with the conventional planar photocathode. The superiority of the wire photocathode is reflected in its structure with surrounding surfaces. The quantum efficiency of the wire photocathode largely depends on the wire width, surface reflectivity, surface escape probability and incident angle of light. The back interface recombination rate, however, has little influences on the quantum efficiency of the wire photocathode. The simulation results suggest that the optimal width for photoemission is 150-200 nm. Besides, the quantum efficiency increases and decreases linearly with increasing surface escape probability and surface reflectivity, respectively. With increasing ratio of wire spacing to wire height, the optimal incident angle of light is reduced. These simulations are expected to guide the preparation of a better performing GaN wire photocathode.

  5. Force systems in the initial phase of orthodontic treatment -- a comparison of different leveling arch wires.

    Science.gov (United States)

    Fuck, Lars-Michael; Drescher, Dieter

    2006-01-01

    The determination of orthodontically-effective forces and moments places great demands on the technical equipment. Many patients report severe pain after fixed appliance insertion. Since it is assumed that pain from orthodontic appliances is associated with the force and moment levels applied to the teeth and since the occurrence of root resorption is a common therapeutic side effect, it would seem important to know the actual magnitudes of the components of the active orthodontic force systems. The aim of the present study was therefore to measure initial force systems produced by different leveling arch-wires in a complete multi-bracket appliance and to assess whether force and moment levels can be regarded as biologically acceptable or not. The actual bracket position in 42 patients was transferred onto a measurement model. Forces and moments produced by a super-elastic nickel-titanium (NiTi) archwire, a 6-strand stainless steel archwire, and a 7-strand super-elastic NiTi archwire were determined experimentally on different teeth. Average forces and moments produced by the super-elastic NiTi arch wires were found to be the highest. In spite if their larger diameter, the stranded arch wires' average force and moment levels were lower, especially that of the stranded super-elastic archwire. Nevertheless, maximum force levels sometimes exceeded recommended values in the literature and must be considered as too high. The measured arch wires' initial force systems differed significantly depending on the type of archwire and its material structure. Stranded arch wires produced lower force and moment levels, and we recommend their use in the initial phase of orthodontic treatment.

  6. Effects of mandibular protraction appliance associated to fixed appliance in adults

    Directory of Open Access Journals (Sweden)

    Bruno D'Aurea Furquim

    2013-10-01

    Full Text Available OBJECTIVE: This retrospective study aimed to conduct a cephalometric evaluation of the skeletal, dental and soft tissue effects resulting from treatment of adult patients presenting Class II malocclusion, performed with a Mandibular Protraction Appliance (MPA combined with a fixed orthodontic appliance. METHODS: The sample consisted of teleradiographs obtained before and after treatment of 9 adult patients (initial mean age of 22.48 years with bilateral Class II, division 1, malocclusion. Paired t test (p < 0.05 was applied to compare initial and final values. RESULTS: t test revealed an increase in anteroinferior facial height and posterior facial height. The dental changes include: extrusion of upper incisors, buccal inclination, protrusion of lower incisors, mesialization and extrusion of mandibular molars. Regarding the soft tissue component, there was an increase in nasolabial angle in addition to upper lip retrusion. CONCLUSIONS: The effects of treating Class II malocclusion adult patients, by means of using Mandibular Protraction Appliance (MPA combined with a fixed appliance were mostly observed in the mandibular arch, and consisted of buccal inclination, protrusion and intrusion of incisors, and mesialization and extrusion of the molars.

  7. The 2D lingual appliance system.

    Science.gov (United States)

    Cacciafesta, Vittorio

    2013-09-01

    The two-dimensional (2D) lingual bracket system represents a valuable treatment option for adult patients seeking a completely invisible orthodontic appliance. The ease of direct or simplified indirect bonding of 2D lingual brackets in combination with low friction mechanics makes it possible to achieve a good functional and aesthetic occlusion, even in the presence of a severe malocclusion. The use of a self-ligating bracket significantly reduces chair-side time for the orthodontist, and the low-profile bracket design greatly improves patient comfort.

  8. Presurgical Orthopedics Appliance: The Latham Technique.

    Science.gov (United States)

    Cruz, Carlos

    2016-05-01

    The Latham appliance is an active presurgical orthopedic device used for cleft defects. Its long-term effects are debated. It was introduced to help surgeons achieve a more predictable surgical outcome; hence, it should be evaluated for its presurgical benefits. The device has been successful in expanding and aligning the maxillary segments; retruding protruded premaxillae; aligning bilateral alveolar ridges; placing less tension on surgical closures; and reducing fistulation rates. However, it has not been shown to have either a positive or negative long-term effect on maxillary development or occlusion. It is a valuable preoperative tool for surgeons treating cleft defects. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...... new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as “wired to freedom,” we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear...

  10. Wiring and lighting

    CERN Document Server

    Kitcher, Chris

    2013-01-01

    Wiring and Lighting provides a comprehensive guide to DIY wiring around the home. It sets out the regulations and legal requirements surrounding electrical installation work, giving clear guidelines that will enable the reader to understand what electrical work they are able to carry out, and what the testing and certification requirements are once the work is completed. Topics covered include: Different types of circuits; Types of cables and cable installation under floors and through joists; Isolating, earthing and bonding; Accessory boxes and fixings; Voltage bands; Detailed advice on safe

  11. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  12. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  13. Orthodontic treatment with preadjusted appliances and low-friction ligatures: experimental evidence and clinical observations.

    Science.gov (United States)

    Baccetti, Tiziano; Franchi, Lorenzo; Fortini, Arturo

    2008-01-01

    To describe the features of low-friction ligatures during the leveling and aligning phase of fixed appliance therapy with preadjusted brackets. Experimental in vitro and in vivo studies were carried out to test the performance of the low-friction system with regard to leveling and aligning of the dental arches, as well as to increasing the transverse dimension of the maxillary arch. The outcomes of experimental testing showed that the combination of the low-friction ligatures with the superelastic nickel-titanium wires produced a significantly smaller amount of binding at the bracket/archwire/ligature unit when compared to conventional elastomeric ligatures. The biomechanical consequences of the use of low-friction ligatures were shorter duration of orthodontic treatment during the leveling and aligning phase, concurrent dentoalveolar expansion of the dental arch, and the possibility of using biologically adequate orthodontic forces.

  14. DC Home Appliances for DC Distribution System

    Directory of Open Access Journals (Sweden)

    MUHAMMAD KAMRAN

    2017-10-01

    Full Text Available This paper strengthens the idea of DC distribution system for DC microgrid consisting of a building of 50 apartments. Since the war of currents AC system has been dominant because of the paucity of research in the protection of the DC system. Now with the advance research in power electronics material and components, generation of electricity is inherently DC as by solar PV, fuel cell and thermoelectric generator that eliminates the rectification process. Transformers are replaced by the power electronics buck-boost converters. DC circuit breakers have solved the protection problems for both DC transmission and distribution system. In this paper 308V DC microgrid is proposed and home appliances (DC internal are modified to operate on 48V DC from DC distribution line. Instead of using universal and induction motors in rotary appliances, BLDC (Brushless DC motors are proposed that are highly efficient with minimum electro-mechanical and no commutation losses. Proposed DC system reduces the power conversion stages, hence diminishes the associated power losses and standby losses that boost the overall system efficiency. So in view of all this a conventional AC system can be replaced by a DC system that has many advantages by cost as well as by performance

  15. Incorporating Experience Curves in Appliance Standards Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Garbesi, Karina; Chan, Peter; Greenblatt, Jeffery; Kantner, Colleen; Lekov, Alex; Meyers, Stephen; Rosenquist, Gregory; Buskirk, Robert Van; Yang, Hung-Chia; Desroches, Louis-Benoit

    2011-10-31

    The technical analyses in support of U.S. energy conservation standards for residential appliances and commercial equipment have typically assumed that manufacturing costs and retail prices remain constant during the projected 30-year analysis period. There is, however, considerable evidence that this assumption does not reflect real market prices. Costs and prices generally fall in relation to cumulative production, a phenomenon known as experience and modeled by a fairly robust empirical experience curve. Using price data from the Bureau of Labor Statistics, and shipment data obtained as part of the standards analysis process, we present U.S. experience curves for room air conditioners, clothes dryers, central air conditioners, furnaces, and refrigerators and freezers. These allow us to develop more representative appliance price projections than the assumption-based approach of constant prices. These experience curves were incorporated into recent energy conservation standards for these products. The impact on the national modeling can be significant, often increasing the net present value of potential standard levels in the analysis. In some cases a previously cost-negative potential standard level demonstrates a benefit when incorporating experience. These results imply that past energy conservation standards analyses may have undervalued the economic benefits of potential standard levels.

  16. Mandibular appliance modulates condylar growth through integrins.

    Science.gov (United States)

    Marques, M Rubia; Hajjar, D; Franchini, K Gomes; Moriscot, A Sigari; Santos, M Fagundes

    2008-02-01

    Functional orthopedic therapy corrects growth discrepancies between the maxilla and mandible, possibly through postural changes in the musculature and modulation of the mandibular condylar cartilage growth. Using Wistar rats, we tested the hypothesis that chondrocytes respond to forces generated by a mandibular propulsor appliance by changes in gene expression, and that integrins are important mediators in this response. Immunohistochemical analyses demonstrated that the use of the appliance for different periods of time modulated the expression of fibronectin, alpha5 and alphav integrin subunits, as well as cell proliferation in the cartilage. In vitro, cyclic distension of condylar cartilage-derived cells increased fibronectin mRNA, as well as Insulin-like Growth Factor-I and II mRNA and cell proliferation. A peptide containing the Arginine-Glycine-Asparagine sequence (RGD), the main cell-binding sequence in fibronectin, blocked almost all these effects, confirming that force itself modulates the growth of the rat condylar cartilage, and that RGD-binding integrins participate in mechanotransduction.

  17. 14 CFR 25.1365 - Electrical appliances, motors, and transformers.

    Science.gov (United States)

    2010-01-01

    ... transformers. 25.1365 Section 25.1365 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF... Equipment § 25.1365 Electrical appliances, motors, and transformers. (a) Domestic appliances must be... transformers, including those installed in domestic systems, must have a suitable thermal protection device to...

  18. Distal driving of molar by smart distal-propeller appliance

    Directory of Open Access Journals (Sweden)

    U H Vijayashree

    2018-01-01

    Full Text Available In recent years, maxillary molar distalization with noncompliance mechanics has been an increasingly popular method for the resolution of Class II malocclusion. This communication describes one particular molar distalizing appliance, the Smart distal-propeller appliance which is simple, inexpensive, easily fabricated that can be used for unilateral or bilateral molar distalization.

  19. 24 CFR 3280.807 - Fixtures and appliances.

    Science.gov (United States)

    2010-04-01

    ... Fixtures and appliances. (a) Electrical materials, devices, appliances, fittings, and other equipment... is provided over a bathtub or in a shower stall, it must be of the enclosed and gasketed type, and be...-2005. (d) The switch for shower lighting fixtures and exhaust fans located over a tub or in a shower...

  20. Convex stoma appliances: an audit of stoma care nurses.

    Science.gov (United States)

    Perrin, Angie

    2016-12-08

    This article observes the complexities surrounding the use of convex appliances within the specialist sphere of stoma care. It highlights some of the results taken from a small audit carried out with 24 stoma care nurses examining the general use of convex appliances and how usage of convex products has evolved, along with specialist stoma care practice.

  1. Appliance choice functions in Canadian households. Paper no. IGEC-1-ID02

    International Nuclear Information System (INIS)

    Aydinalp, M.; Fung, A.; Ugursal, V.I.

    2005-01-01

    Decisions regarding the purchase of various types of major household appliances are influenced by the economic and demographic characteristics of households, i.e., appliance customers. It is therefore necessary to understand the relationship between these characteristics and the decisions made regarding the purchase of appliances to be able to predict future trends in appliance purchases, and consequently, the future appliance energy consumption of the national stock of appliances. In this paper, a methodology is presented to develop choice functions for the purchase of new major household appliances. This methodology is used to develop appliance choice functions for Canada. (author)

  2. [Evaluation of three dimensional orthodontic force produced by magnet of fix appliance].

    Science.gov (United States)

    Dai, Xin; Hou, Zhi-ming; Yao, Ge; Wen, Jing-long

    2008-12-01

    To analyze the feature and magnitude of three dimensional orthodontic force produced by the magnet of fix appliance. Forces detected by universal fatigue test system included the attractive and repulsive,the inclined and rotated orthodontic forces of two magnets in different air gaps, and the integrated inclined and rotated orthodontic forces of two magnets and NiTi wire. The attractive and repulsive forces of two magnets were 4.68 to 0.45 N and 3.00 to 0.40 N respectively in the air gaps of 0 to 5 mm. The inclined orthodontic forces were 1.54 to 1.67 N, 0.63 to 0.69 N, 0.47 to 0.54 N when the magnets were vertically inclined 10 degrees to 40 degrees in the air gaps of 0, 1, 2mm. The rotated orthodontic forces were 0.97 to 1.32 N, 0.53 to 0.59 N, 0.39 to 0.48 N when the magnets were horizontally rotated 10 degrees to 40 degrees in the air gaps of 0, 1, 2mm. The integrated orthodontic force of two magnets and 0.014-inch NiTi wire was 0.32 to 0.5 N when the magnets was vertically inclined 10 degrees to 40 degrees in the air gap of 4 mm. The integrated orthodontic force of two magnets and 0.012-inch NiTi wire was 0.32 to 0.39 N when the magnets were horizontally rotated 10 degrees to 40 degrees in the air gap of 3 mm. Magnets made into orthodontic brackets to some extent could replace the mechanical orthodontic force produced by orthodontic wires and elastics.

  3. Embedded Systems for Smart Appliances and Energy Management

    CERN Document Server

    Neumann, Peter; Mahlknecht, Stefan

    2013-01-01

    This book provides a comprehensive introduction to embedded systems for smart appliances and energy management, bringing together for the first time a multidisciplinary blend of topics from embedded systems, information technology and power engineering.  Coverage includes challenges for future resource distribution grids, energy management in smart appliances, micro energy generation, demand response management, ultra-low power stand by, smart standby and communication networks in home and building automation.   Provides a comprehensive, multidisciplinary introduction to embedded systems for smart appliances and energy management; Equips researchers and engineers with information required to succeed in designing energy management for smart appliances; Includes coverage of resource distribution grids, energy management in smart appliances, micro energy generation, demand response management, ultra-low power stand by, smart standby and communication networks in home and building automation.  

  4. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  5. Wire EDM for Refractory Materials

    Science.gov (United States)

    Zellars, G. R.; Harris, F. E.; Lowell, C. E.; Pollman, W. M.; Rys, V. J.; Wills, R. J.

    1982-01-01

    In an attempt to reduce fabrication time and costs, Wire Electrical Discharge Machine (Wire EDM) method was investigated as tool for fabricating matched blade roots and disk slots. Eight high-strength nickel-base superalloys were used. Computer-controlled Wire EDM technique provided high quality surfaces with excellent dimensional tolerances. Wire EDM method offers potential for substantial reductions in fabrication costs for "hard to machine" alloys and electrically conductive materials in specific high-precision applications.

  6. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  7. Command Wire Sensor Measurements

    Science.gov (United States)

    2012-09-01

    CFAR Constant False Alarm Rate CWIE Command Wire-Improvised Explosive Device EMI Electromagnetic Induction GPR Ground Penetrating Radar...this, some type of constant false alarm rate ( CFAR ) receiver is required. CFAR automatically raises the threshold level to keep clutter echoes and

  8. Transport in quantum wires

    Indian Academy of Sciences (India)

    Transport in quantum wires. SIDDHARTHA LAL, SUMATHI RAO£ and DIPTIMAN SEN. Centre for Theoretical Studies, Indian Institute of Science, Bangalore 560 012, India. £ Harish-chandra Research Institute, Chhatnag Road, Jhusi, Allahabad 211 019, India. Abstract. With a brief introduction to one-dimensional channels ...

  9. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  10. Implementing peak load reduction algorithms for household electrical appliances

    International Nuclear Information System (INIS)

    Dlamini, Ndumiso G.; Cromieres, Fabien

    2012-01-01

    Considering household appliance automation for reduction of household peak power demand, this study explored aspects of the interaction between household automation technology and human behaviour. Given a programmable household appliance switching system, and user-reported appliance use times, we simulated the load reduction effectiveness of three types of algorithms, which were applied at both the single household level and across all 30 households. All three algorithms effected significant load reductions, while the least-to-highest potential user inconvenience ranking was: coordinating the timing of frequent intermittent loads (algorithm 2); moving period-of-day time-flexible loads to off-peak times (algorithm 1); and applying short-term time delays to avoid high peaks (algorithm 3) (least accommodating). Peak reduction was facilitated by load interruptibility, time of use flexibility and the willingness of users to forgo impulsive appliance use. We conclude that a general factor determining the ability to shift the load due to a particular appliance is the time-buffering between the service delivered and the power demand of an appliance. Time-buffering can be ‘technologically inherent’, due to human habits, or realised by managing user expectations. There are implications for the design of appliances and home automation systems. - Highlights: ► We explored the interaction between appliance automation and human behaviour. ► There is potential for considerable load shifting of household appliances. ► Load shifting for load reduction is eased with increased time buffering. ► Design, human habits and user expectations all influence time buffering. ► Certain automation and appliance design features can facilitate load shifting.

  11. Crew appliance concepts. Volume 4, appendix C: Modular space station appliances supporting engineering data. [food management and personal hygiene

    Science.gov (United States)

    Proctor, B. W.; Reysa, R. P.; Russell, D. J.

    1975-01-01

    Data collected for the appliances considered for the space station are presented along with plotted and tabulated trade study results for each appliance. The food management, and personal hygiene data are applicable to a six-man mission of 180-days.

  12. Crew appliance concepts. Volume 2, appendix B: Shuttle orbiter appliances supporting engineering data. [food management and personal hygiene

    Science.gov (United States)

    Proctor, B. W.; Reysa, R. P.; Russell, D. J.

    1975-01-01

    Technical data collected for the food management and personal hygiene appliances considered for the shuttle orbiter are presented as well as plotted and tabulated trade study results for each appliance. Food storage, food operation, galley cleanup, waste collection/transfer, body cleansing, and personal grooming were analyzed.

  13. GE Appliance Park Louisville, KY Plant Wide Assessment Final Report October 25th, 2007

    Energy Technology Data Exchange (ETDEWEB)

    Chandon Rao; Richard Urschel

    2007-10-25

    Used a team of experts to analyze and model major systems at a large industrial appliance manufacturer. During the data gathering stage, the team specifically looked for baselining the efficiency of the systems as well as developing short term and longer term efficiency projects. Electrical distribution, Compressed air generation and thermal heat recovery for the production facility and front office heating and cooling optimization were all baselined during the study.

  14. Research regarding wires elastic deformations influence on joints positioning of a wire-driven robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-08-01

    In this paper, we present the influence of driving wires deformation on positioning precision of joints from an elephant's trunk robotic arm. Robotic arms driven by wires have the joint accuracy largely depending on wires rigidity. The joint moment of resistance causes elastic deformation of wires and it is determined by: manipulated object load, weight loads previous to the analyzed joint and inherent resistance moment of joint. Static load analysis emphasizes the particular wires elastic deformation of each driven joint from an elephant's trunk robotic arm with five degrees of freedom. We consider the case of a constant manipulated load. Errors from each driving system of joints are not part of the closed loop system. Thus, precision positioning depends on wires elastic deformation which is about microns and causes angle deviation of joints about tens of minutes of sexagesimal degrees. The closer the joints to base arm the smaller positioning precision of joint. The obtained results are necessary for further compensation made by electronic corrections in the programming algorithm of the elephant's trunk robotic arm to improve accuracy.

  15. Control of flow past a circular cylinder via a spanwise surface wire: effect of the wire scale

    Energy Technology Data Exchange (ETDEWEB)

    Ekmekci, Alis [University of Toronto Institute for Aerospace Studies, Toronto, ON (Canada); Rockwell, Donald [Lehigh University, Department of Mechanical Engineering, Bethlehem, PA (United States)

    2011-09-15

    Flow phenomena induced by a single spanwise wire on the surface of a circular cylinder are investigated via a cinema technique of particle image velocimetry (PIV). The primary aim of this investigation is to assess the effect of the wire scale. To this end, consideration is given to wires with different diameters that are 0.5, 1.2, and 2.9% of the cylinder diameter. The Reynolds number has a subcritical value of 10,000. Compared to the thickness of the unperturbed boundary layer developing around the cylinder between 5 and 75 from the forward stagnation point, the former two wires have smaller scales and the latter has a larger scale. Two angular locations of the wire, defined with respect to the forward stagnation point of the cylinder, are found to be critical. When the wire is located at these critical angles, either the most significant extension or the contraction of the time-mean separation bubble occurs in the near wake. These critical angles depend on the wire scale: the smaller the wire, the larger the critical angle. The small-scale and large-scale wires that have diameters of 1.2 and 2.9% of the cylinder diameter induce bistable shear-layer oscillations between different separation modes when placed at their respective critical angles corresponding to maximum extension of the near-wake bubble. These oscillations have irregular time intervals that are much longer than the time scale associated with the classical Karman instability. Moreover, the large-scale wire can either significantly attenuate or intensify the Karman mode of vortex shedding at the critical states; in contrast, the small-scale wires do not notably alter the strength of the Karman instability. (orig.)

  16. Turning the Appliance Market Around towards A++

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen; Brange, Birgitte; Guldbrandsen, Tom

    2007-01-01

    in the course of a few years. Where models C, D, E earlier dominated the market, the A, A+ and A++, came to dominate as the standard models in stock. Consequently, their prices dropped significantly. The theory of a rational market behavior is based on some assumptions, one being that full information...... energy efficient model within their specification, and 4) in the website are also listed the shops, where consumers can get the appliances at lowest prices. The latter was the most innovative and maybe also the most effective measure in the package. Results showed up as a permanent U-turn of the market...... is available to all actors. The website identifying to the consumers the shops with the lowest priced efficient models was a step in that direction, and the result did not fail to turn up....

  17. Angle Class II correction with MARA appliance

    Directory of Open Access Journals (Sweden)

    Kelly Chiqueto

    2013-02-01

    Full Text Available OBJECTIVE: To assess the effects produced by the MARA appliance in the treatment of Angle's Class II, division 1 malocclusion. METHODS: The sample consisted of 44 young patients divided into two groups: The MARA Group, with initial mean age of 11.99 years, treated with the MARA appliance for an average period of 1.11 years, and the Control Group, with initial mean age of 11.63 years, monitored for a mean period of 1.18 years with no treatment. Lateral cephalograms were used to compare the groups using cephalometric variables in the initial and final phases. For these comparisons, Student's t test was employed. RESULTS: MARA appliance produced the following effects: Maxillary growth restriction, no change in mandibular development, improvement in maxillomandibular relationship, increased lower anterior facial height and counterclockwise rotation of the functional occlusal plane. In the upper arch, the incisors moved lingually and retruded, while the molars moved distally and tipped distally. In the lower arch, the incisors proclined and protruded, whereas the molars mesialized and tipped mesially. Finally, there was a significant reduction in overbite and overjet, with an obvious improvement in molar relationship. CONCLUSIONS: It was concluded that the MARA appliance proved effective in correcting Angle's Class II, division 1 malocclusion while inducing skeletal changes and particularly dental changes.OBJETIVO: avaliar os efeitos proporcionados pelo aparelho MARA no tratamento da má oclusão de Classe II, 1ª divisão. MÉTODOS: utilizou-se uma amostra de 44 jovens, divididos em dois grupos - Grupo MARA, com idade inicial média de 11,99 anos e tratado com o aparelho MARA por um período médio de 1,11 ano; e Grupo Controle, com idade inicial média de 11,63 ano e observado por um período médio de 1,18 ano, sem nenhum tratamento. Utilizou-se as telerradiografias em norma lateral para comparar os grupos quanto às variáveis cefalométricas das

  18. Oral health with fixed appliances orthodontics

    Directory of Open Access Journals (Sweden)

    Konta, Brigitte

    2008-03-01

    Full Text Available Orthodontic treatment represents an important fraction in dental interventions. According to other medical methods the question for scientific evidence for the effectiveness of these treatments arises. The question of the effectiveness is connected with the question what is understood as an effect. In principle, the effect of the intervention is understood on the basis of the occlusion or dental health, what disregards further functions of oral health. The generalization to oral health is therefore a necessary consideration in science now. If one appreciates this further development, then there is no one single randomised study available which examines the long-term effect of the orthodontic intervention or for the effects on the oral health. The question, whether the application of a fixed appliance in an orthodontic treatment causes a long-term improvement in oral health, cannot be answered at the present time. The scientific status is the definition of oral health at present. Also the question, whether in the long run the dental health can be improved by fixed appliances cannot be answered with a quality usually achieved by evidence-based medicine. Whether correction of a dental malposition is an effective prerequisite for the preservation of the natural teeth, cannot be answered. There is no generalizing study with sufficient scientific background for Europe or Germany to this topic. The risk for caries cannot be quantified. Caries is identified as a central topic in general but due to numerous factors influencing the risk it is not quantified. The question of the indications is completely open from the scientific literature. For the question of the therapy need or therapy priority some indexes were developed, which lead to a quantification. These indices however are fundamentally criticised by recent research in their meaning and the empirical relevance. There is an impression that there exists a big gap between the practical application

  19. Decision-making in electrical appliance use in the home

    International Nuclear Information System (INIS)

    Yamamoto, Yoshihiro; Suzuki, Akihiko; Fuwa, Yasuhiro; Sato, Tomohiro

    2008-01-01

    This paper presents the results of a survey as well as an argument from the viewpoint of behavioral economics with the aim of clarifying how consumers make decisions about electrical appliance use in the home. A survey of consumers showed that most have little awareness of the energy efficiency of appliances, the price of the services produced by electrical appliances, or electricity rates. These findings indicate that price does not function as a signal in electricity consumption through electrical appliance use. Rather, we found that consumer decision-making in electricity consumption is dependent on the characteristics of the particular electrical appliances they use. Additionally, we argue that the payment system for home electricity consumption plays an important role in decision-making, causing biases due to aspects of human psychology discussed here in terms of satisficing and heuristics, payment decoupling, and budgeting. We conclude that decision-making about electrical appliance use and electricity consumption in the home is not always rational and is affected both by the particular characteristics of appliances and the payment system for electricity consumption along with human psychology

  20. Orthodontic bone remodeling in relation to appliance decay.

    Science.gov (United States)

    King, G J; Keeling, S D

    1995-01-01

    This study examined alveolar bone turnover and orthodontic tooth movement after appliance decay. One group of rats (N = 54) received orthodontic force (40 g initial activation) while the other (N = 36) was sham-treated. Groups of six rats were sacrificed at various times following activation. Tooth movement and appliance decay were monitored cephalometrically, and bone turnover was monitored locally by histomorphometry and phosphatase chemistries and systemically by serum phosphatase and osteocalcin changes. A significant association was found between spring forces assessed by direct measurement and by cephalometric images (R2 = 0.784; p = 0.02). The cephalometric method indicated appliances were at least 93% deactivated by day 16. Tooth movement continued beyond the point of appliance decay (p osteocalcin also increased after appliance decay (p < 0.05), but alkaline phosphatase did not. Bone acid phosphatase was characterized by a peak after appliance decay (p = 0.0004), but alkaline phosphatase remained depressed (p < 0.0001). These data demonstrate that significant amounts of alveolar bone turnover continue for an indeterminant period following appliance decay.

  1. Electrical field of electrical appliances versus distance: A preliminary analysis

    International Nuclear Information System (INIS)

    Mustafa, Nur Badariah Ahmad; Nordin, Farah Hani; Ismail, Fakaruddin Ali Ahmad; Alkahtani, Ammar Ahmed; Balasubramaniam, Nagaletchumi; Hock, Goh Chin; Shariff, Z A M

    2013-01-01

    Every household electrical appliance that is plugged in emits electric field even if it is not operating. The source where the appliance is plugged into and the components of household electrical appliance contribute to electric field emission. The electric field may cause unknown disturbance to the environment or also affect the human health and the effect might depends on the strength of the electric field emitted by the appliance. This paper will investigate the strength of the electric field emitted by four different electrical appliances using spectrum analyser. The strength will be captured at three different distances; (i) 1m (ii) 2m and (iii) 3m and analysis of the strength of the electrical field is done based on the three different distances. The measurement results show that the strength of the electric field is strongest when it is captured at 1m and the weakest at 3m from the electrical appliance. The results proved that the farther an object is located from the electrical appliance; the less effect the magnetic field has.

  2. Release of nickel and chromium ions from orthodontic wires following the use of teeth whitening mouthwashes

    Directory of Open Access Journals (Sweden)

    AmirHossein Mirhashemi

    2018-02-01

    Full Text Available Abstract Background Corrosion resistance is an important requirement for orthodontic appliances. Nickel and chromium may be released from orthodontic wires and can cause allergic reactions and cytotoxicity when patients use various mouthwashes to whiten their teeth. Our study aimed to assess the release of nickel and chromium ions from nickel titanium (NiTi and stainless steel (SS orthodontic wires following the use of four common mouthwashes available on the market. Methods This in vitro, experimental study was conducted on 120 orthodontic appliances for one maxillary quadrant including five brackets, one band and half of the required length of SS, and NiTi wires. The samples were immersed in Oral B, Oral B 3D White Luxe, Listerine, and Listerine Advance White for 1, 6, 24, and 168 h. The samples immersed in distilled water served as the control group. Atomic absorption spectroscopy served to quantify the amount of released ions. Results Nickel ions were released from both wires at all time-points; the highest amount was in Listerine and the lowest in Oral B mouthwashes. The remaining two solutions were in-between this range. The process of release of chromium from the SS wire was the same as that of nickel. However, the release trend in NiTi wires was not uniform. Conclusions Listerine caused the highest release of ions. Listerine Advance White, Oral B 3D White Luxe, and distilled water were the same in terms of ion release. Oral B showed the lowest amount of ion release.

  3. Hierarchical structures in cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2013-01-01

    The microstructure and crystallography of drawn pearlitic steel wires have been quantified by a number of electron microscopy techniques including scanning electron microscopy, transmission electron microscopy, electron backscatter diffraction and nanobeam diffraction, with focus on the change...... in the structure and crystallography when a randomly oriented cementite structure in a patented wire during wire drawing is transformed into a lamellar structure parallel to the drawing axis. Changes in the interlamellar spacing and in the misorientation angle along and across the ferrite lamellae show significant...... through-diameter variations in wires drawn to large strains P 1.5. The structural evolution is hierarchical as the structural variations have their cause in a different macroscopic orientation of the cementite in the initial (patented) structure with respect to the wire axis. The through...

  4. Single Wire Detector Performance Over One Year of Operation

    CERN Document Server

    Hervas Aguilar, David Alberto

    2014-01-01

    Abstract When ionizing radiation passes through gas chambers in single wire detectors gas molecules separate into ions and electrons. By applying a strong localized electric field near the single wire an avalanche of electrons is created and it can be collected. The current produced in the wire is then proportional to the energy of the particle detected. Nevertheless, many factors can contribute to detector aging effects which are visible in a loss of gain caused by deposition of contaminants on the collecting wire. This study consists on novel data analysis techniques used to process large amounts of data produced by two simultaneously running single wire detectors. Aging effects are analyzed while environmental fluctuations are corrected for. A series of scripts carry out data filtering, data matching, corrections, and finally trend plotting by using ROOT’s extensive libraries developed at CERN.

  5. Oxidative Stress Evaluation in Patients Treated with Orthodontic Self-ligating Multibracket Appliances: An in Vivo Case-Control Study.

    Science.gov (United States)

    Portelli, Marco; Militi, Angela; Cervino, Gabriele; Lauritano, Floriana; Sambataro, Sergio; Mainardi, Alberto; Nucera, Riccardo

    2017-01-01

    Oxidative stress is a pathologic event induced by a prevalence of oxidant agents on the antioxidant ones, with a consequent alteration of oxide-reducing balance. Freeradicals produce damages both in cellular and extra-cellular components; phospholipid membranes, proteins, mitochondrial and nuclear DNA, are the target of the oxidative stress, that can finally cause cellular death due to apoptosis. Orthodontic appliances such as brackets, wires, resins and soldering have some components that can be considered as potential allergen, carcinogenic, cytotoxic and gene mutation factors. The primary aim of this research is to evaluate oxidative stress in the saliva of patients treated with multibracket self-ligating vestibular orthodontic appliances; the secondary purpose is to investigate the influence of orthodontic multibracket therapy on oral hygiene and the consequent effect on oxidative stress. Salivary specimens has been collected in a sample of 23 patients were enrolled (12 Female, 11 Male) between 12 and 16 years of age (mean age 14.2). For each patient has been collected a salivary specimen at the following time points; before orthodontic bonding (T1), five weeks (T2) and ten weeks (T3) after orthodontic appliance bonding. Samples has been analysed with a photometer due to SAT Test (Salivary Antioxidant Test). Data obtained show a mean of 2971 mEq/l of anti-oxidant agents before orthodontic treatment, and after five weeks from the bonding the mean was decreased to 2909 mEq/l, instead at ten weeks was increased to 3332 mEq/l. Repeated measures ANOVA did not reveal statistically significant differences between the time points ( P = 0.1697). The study did not reveal any correlation between the level of dental hygiene and that of oxidative stress (Pearson Correlation Coefficient R = 0). Orthodontic treatment with multibrackets vestibular metallic appliance seems to be not able to affect oxidative stress during the first ten weeks of therapy.

  6. Dental Arch Wire

    Science.gov (United States)

    1979-01-01

    Straightening teeth is an arduous process requiring months, often years, of applying corrective pressure by means of arch wires-better known as brace-which may have to be changed several times in the course of treatment. A new method has been developed by Dr. George Andreasen, orthodontist and dental scientist at the University of Iowa. The key is a new type of arch wire material, called Nitinol, with exceptional elasticity which helps reduce the required number of brace changes. An alloy of nickel and titanium, Nitinol was originally developed for aerospace applications by the Naval Ordnance Laboratory, now the Naval Surface Weapons Laboratory, White Oaks, Maryland. NASA subsequently conducted additional research on the properties of Nitinol and on procedures for processing the metal.

  7. Correction of Skeletal Class II Malocclusion using Functional-Fixed Appliance Therapy

    Directory of Open Access Journals (Sweden)

    Ashok Surana

    2012-01-01

    Full Text Available Single-phase treatment started during late mixed dentition using functional followed by fixed appliance therapy has proven to be the most effective approach to achieve correction of Class II malocclusion. This case report demonstrates the use of this treatment approach in an 11-year-old girl with skeletal and dental Class II malocclusion, large overjet, deep overbite, increased incisor exposure and a gummy smile. She was given a functional appliance for 1 year which was immediately followed by fixed mechanotherapy for final finishing and detailing of the occlusion. The magnitude of skeletal and dental correction achieved, along with the dramatic improvement in facial appearance of the patient, provides a strong case for establishing the efficacy of this treatment modality.

  8. Research & Development Roadmap for Next-Generation Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States); Foley, Kevin [Navigant Consulting, Inc., Burlington, MA (United States)

    2012-03-01

    Appliances present an attractive opportunity for near-term energy savings in existing building, because they are less expensive and replaced more regularly than heating, ventilation, and air-conditioning (HVAC) systems or building envelope components. This roadmap targets high-priority research and development (R&D), demonstration and commercialization activities that could significantly reduce residential appliance energy consumption. The main objective of the roadmap is to seek activities that accelerate the commercialization of high-efficiency appliance technologies while maintaining the competitiveness of American industry. The roadmap identified and evaluated potential technical innovations, defined research needs, created preliminary research and development roadmaps, and obtained stakeholder feedback on the proposed initiatives.

  9. Pyogenic granuloma: a rare side complication from an orthodontic appliance.

    Science.gov (United States)

    Acharya, Priti N; Gill, Daljit; Lloyd, Tim

    2011-12-01

    This case report discusses a rare side effect associated with the use ofa fixed quad helix orthodontic appliance. A 14-year-old healthy girl presented with a painful enlarging mass on her tongue, which was causing distress to both her and her parents. Investigations confirmed that the mass was a pyogenic granuloma and management involved surgical excision of the mass and removal of the quad helix appliance. At least once previous case associated with an orthodontic quad helix appliance has been reported in the literature.

  10. Effective Maxillary Protraction with Tandem Traction Bow Appliance

    Directory of Open Access Journals (Sweden)

    Pravin Kumar S Marure

    2014-01-01

    Full Text Available Tandem traction bow appliance (TTBA promotes patient compliance, because it is more esthetic and comfortable than extraoral appliances. TTBA should be used only in case where maxillary deficiency and normal mandible is present. Advantages of it includes good oral hygiene, early treatment of any Class III malocclusion, optimal retention, distribution of the forces for protraction to all maxillary teeth, free mandibular movement. It can be used in conjunction with fixed appliances if necessary. This paper includes two case reports. The treatment results in both the cases demonstrated significant skeletal and dental response to TTBA therapy. Skeletal change was primarily a result of anterior movement of the maxilla.

  11. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  12. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  13. Study on Semantic Assets for Smart Appliances Interoperability : D-S3: THIRD INTERIM REPORT

    NARCIS (Netherlands)

    Daniele, L.M.; Hartog, F.T.H. den; Roes, J.B.M.

    2015-01-01

    About two thirds of the energy consumed by buildings originates from the residential sectors and thus household appliances. Household appliances or home appliances are electrical/mechanical machines which accomplish some household functions. Nowadays, appliances are not stand-alone systems anymore.

  14. Study on Semantic Assets for Smart Appliances Interoperability : D-S2: SECOND INTERIM REPORT

    NARCIS (Netherlands)

    Daniele, L.M.; Hartog, F.T.H. den; Roes, J.B.M.

    2014-01-01

    About two thirds of the energy consumed by buildings originates from the residential sectors and thus household appliances. Household appliances or home appliances are electrical/mechanical machines which accomplish some household functions. Nowadays, appliances are not stand-alone systems anymore.

  15. Study on Semantic Assets for Smart Appliances Interoperability : D-S1: FIRST INTERIM REPORT

    NARCIS (Netherlands)

    Hartog, F.T.H. den; Daniele, L.M.; Roes, J.B.M.

    2014-01-01

    About two thirds of the energy consumed by buildings originates from the residential sectors and thus household appliances. Household appliances or home appliances are electrical/mechanical machines which accomplish some household functions. Nowadays, appliances are not stand-alone systems anymore.

  16. A retrospective cephalometric investigation of two fixed functional orthodontic appliances in class II treatment: Functional Mandibular Advancer vs. Herbst appliance.

    Science.gov (United States)

    Kinzinger, Gero Stefan Michael; Lisson, Jörg Alexander; Frye, Linda; Gross, Ulrich; Hourfar, Jan

    2018-01-01

    The objective of the study is to compare skeletal and dental changes in class II patients treated with fixed functional appliances (FFA) that pursue different biomechanical concepts: (1) FMA (Functional Mandibular Advancer) from first maxillary molar to first mandibular molar through inclined planes and (2) Herbst appliance from first maxillary molar to lower first bicuspid through a rod-and-tube mechanism. Forty-two equally distributed patients were treated with FMA (21) and Herbst appliance (21), following a single-step advancement protocol. Lateral cephalograms were available before treatment and immediately after removal of the FFA. The lateral cephalograms were analyzed with customized linear measurements. The actual therapeutic effect was then calculated through comparison with data from a growth survey. Additionally, the ratio of skeletal and dental contributions to molar and overjet correction for both FFA was calculated. Data was analyzed by means of one-sample Student's t tests and independent Student's t tests. Statistical significance was set at p appliance were found, intergroup comparisons showed no statistically significant differences. Almost all measurements resulted in comparable changes for both appliances. Statistically significant dental changes occurred with both appliances. Dentoalveolar contribution to the treatment effect was ≥70%, thus always resulting in ≤30% for skeletal alterations. FMA and Herbst appliance usage results in comparable skeletal and dental treatment effects despite different biomechanical approaches. Treatment leads to overjet and molar relationship correction that is mainly caused by significant dentoalveolar changes.

  17. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  18. 38 CFR 17.150 - Prosthetic and similar appliances.

    Science.gov (United States)

    2010-07-01

    .... Artificial limbs, braces, orthopedic shoes, hearing aids, wheelchairs, medical accessories, similar... necessary by the wearing of such appliances, may be purchased, made or repaired for any veteran upon a...

  19. Waste Home Appliance Disposal and Low Temperature Crushing Technology

    Science.gov (United States)

    Hayashi, Masakatsu; Takamura, Yoshiyuki

    From the viewpoint of environmental preservation, considerable interest is being advanced by the recycling of industrial goods such as home appliances. In terms of waste home appliances, there is an urgent need for an improvement in recycling rates for waste, because four items (refrigerators, airconditioners, washing machines and televisions) were designated as primary specified goods under those laws that encourage the use of recycled materials. Under this situation, new merits are being discovered in low temperature crushing technology as an appropriate disposal technology for recycling activities. Here, crushing and separating technology for metal composites, and crushing and sorting technology for plastics will be introduced as examples of low temperature crushing technology developed for waste home appliances that achieves recycling rates of over 90% through recycle system for waste home appliances.

  20. Estimation of Standby Power Consumption for Typical Appliances

    Directory of Open Access Journals (Sweden)

    P. Philomen-D-Anand Raj

    2009-01-01

    Full Text Available In the past days, many consumers could simply unplug their appliances and go on holidays, assuming that their electricitymeter would just stop. Standby power is a power consumed by an appliance when switched off or not performing its primaryfunctions. Standby power consumption provides good opportunity for reducing both energy consumption and green housegas emissions. Through co-operation among governments, industry and consumers and the co-ordination of internationalpolicies, standby modes can be made more efficient, thereby reducing the overall demand for power.In this paper, standby power consumption of various domestic appliances was determined using an energy cost meter. Theexperimental results shows that the standby power of various house hold electrical appliances is consuming more electricityduring standby mode

  1. Estimation of Standby Power Consumption for Typical Appliances

    Directory of Open Access Journals (Sweden)

    P. Philomen-D-Anand Raj

    2009-01-01

    Full Text Available In the past days, many consumers could simply unplug their appliances and go on holidays, assuming that their electricitymeter would just stop. Standby power is a power consumed by an appliance when switched off or not performing its primaryfunctions. Standby power consumption provides good oppourtunity for reducing both energy consumption and green housegas emissions. Through co-operation among governments, industry and consumers and the co-ordination of internationalpolicies, standby modes can be made more efficient, thereby reducing the overall demand for power.In this paper, standby power consumption of various domestic appliances was determined using an energy cost meter. Theexperimental results shows that the standby power of various house hold electrical appliances is consuming more electricityduring standby mode.

  2. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  3. Clinical Aspects of Combination of Aesthetic Fixed Orthopedic Appliances

    OpenAIRE

    Ozhohan, Z. R.; Biben, A. B.

    2016-01-01

    The article presents the results of examination of 80 patients with aesthetic fixed orthopedic appliances. The state of the occlusal surface of fixed orthopedic appliances as well as the occlusal contact surface area was studied. The occlusal surfaces were made of ceramics and zirconium dioxide. The surface area of occlusal contacts was studied using 3Shape Dental System since computer occlusiography provides the most accurate results. Physical examination indicated a higher level of ceramic ...

  4. Esthetic perception of orthodontic appliances by Brazilian children and adolescents

    OpenAIRE

    Kuhlman,Deise Caldas; Lima,Tatiana Araújo de; Duplat,Candice Belchior; Capelli Junior,Jonas

    2016-01-01

    ABSTRACT Objective: The objective of this present study was to understand how children and adolescents perceive esthetic attractiveness of a variety of orthodontic appliances. It also analyzed preferences according to patients' age, sex and socioeconomic status. Methods: A photograph album consisting of eight photographs of different orthodontic appliances and clear tray aligners placed in a consenting adult with pleasing smile was used. A sample of children or adolescents aged between 8 ...

  5. Treatment with active orthodontic appliance in adult patient

    OpenAIRE

    Radeska, Ana; Radeski, Josif; Zlatanovska, Katerina; Papakoca, Kiro; Zarkova, Julija

    2012-01-01

    Aim: Showing the efficiency of orthodontic mobile appliance in treatment of adult patient Case summary: The patient A.K. Age 25 years whit forced progenia, bilateral hypodontia of the maxillary incisors and cross bite of 2 mm in front. The patient was treated with active orthodontic appliance whit bitten ridge and down labial arch. The treatment lasted 18 months after which periods is reached normal occlusion with normal overlap in front and closed diastema mediana. The hypodontia of the m...

  6. Estimating Price Elasticity using Market-Level Appliance Data

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, K. Sydny [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-08-04

    This report provides and update to and expansion upon our 2008 LBNL report “An Analysis of the Price Elasticity of Demand for Appliances,” in which we estimated an average relative price elasticity of -0.34 for major household appliances (Dale and Fujita 2008). Consumer responsiveness to price change is a key component of energy efficiency policy analysis; these policies influence consumer purchases through price both explicitly and implicitly. However, few studies address appliance demand elasticity in the U.S. market and public data sources are generally insufficient for rigorous estimation. Therefore, analysts have relied on a small set of outdated papers focused on limited appliance types, assuming long-term elasticities estimated for other durables (e.g., vehicles) decades ago are applicable to current and future appliance purchasing behavior. We aim to partially rectify this problem in the context of appliance efficiency standards by revisiting our previous analysis, utilizing data released over the last ten years and identifying additional estimates of durable goods price elasticities in the literature. Reviewing the literature, we find the following ranges of market-level price elasticities: -0.14 to -0.42 for appliances; -0.30 to -1.28 for automobiles; -0.47 to -2.55 for other durable goods. Brand price elasticities are substantially higher for these product groups, with most estimates -2.0 or more elastic. Using market-level shipments, sales value, and efficiency level data for 1989-2009, we run various iterations of a log-log regression model, arriving at a recommended range of short run appliance price elasticity between -0.4 and -0.5, with a default value of -0.45.

  7. Esthetic perception of orthodontic appliances by Brazilian children and adolescents.

    Science.gov (United States)

    Kuhlman, Deise Caldas; Lima, Tatiana Araújo de; Duplat, Candice Belchior; Capelli, Jonas

    2016-01-01

    The objective of this present study was to understand how children and adolescents perceive esthetic attractiveness of a variety of orthodontic appliances. It also analyzed preferences according to patients' age, sex and socioeconomic status. A photograph album consisting of eight photographs of different orthodontic appliances and clear tray aligners placed in a consenting adult with pleasing smile was used. A sample of children or adolescents aged between 8 and 17 years old (n = 276) was asked to rate each image for its attractiveness on a visual analog scale. Comparisons between the appliances attractiveness were performed by means of nonparametric statistics with Friedman's test followed by Dunn's multiple comparison post-hoc test. Correlation between appliances and individuals' socioeconomic status, age, sex, and esthetic perception was assessed by means of Spearman's correlation analysis. Attractiveness ratings of orthodontic appliances varied nonsignificantly for children in the following hierarchy: traditional metallic brackets with green elastomeric ligatures > traditional metallic brackets with gray elastomeric ligatures > sapphire esthetic brackets; and for adolescents, as follows: sapphire esthetic brackets > clear aligner without attachments > traditional metallic brackets with green elastomeric ligatures. The correlation between individuals' socioeconomic status and esthetic perception of a given appliance was negative and statistically significant for appliances such as the golden orthodontic brackets and traditional metallic brackets with green elastomeric ligatures. Metal appliances were considered very attractive, whereas aligners were classified as less attractive by children and adolescents. The correlation between esthetic perception and socioeconomic status revealed that individuals with a higher socioeconomic level judged esthetics as the most attractive attribute. For those with higher economic status, golden orthodontic brackets and

  8. Esthetic perception of orthodontic appliances by Brazilian children and adolescents

    Directory of Open Access Journals (Sweden)

    Deise Caldas Kuhlman

    Full Text Available ABSTRACT Objective: The objective of this present study was to understand how children and adolescents perceive esthetic attractiveness of a variety of orthodontic appliances. It also analyzed preferences according to patients' age, sex and socioeconomic status. Methods: A photograph album consisting of eight photographs of different orthodontic appliances and clear tray aligners placed in a consenting adult with pleasing smile was used. A sample of children or adolescents aged between 8 and 17 years old (n = 276 was asked to rate each image for its attractiveness on a visual analog scale. Comparisons between the appliances attractiveness were performed by means of nonparametric statistics with Friedman's test followed by Dunn's multiple comparison post-hoc test. Correlation between appliances and individuals' socioeconomic status, age, sex, and esthetic perception was assessed by means of Spearman's correlation analysis. Results: Attractiveness ratings of orthodontic appliances varied nonsignificantly for children in the following hierarchy: traditional metallic brackets with green elastomeric ligatures > traditional metallic brackets with gray elastomeric ligatures > sapphire esthetic brackets; and for adolescents, as follows: sapphire esthetic brackets > clear aligner without attachments > traditional metallic brackets with green elastomeric ligatures. The correlation between individuals' socioeconomic status and esthetic perception of a given appliance was negative and statistically significant for appliances such as the golden orthodontic brackets and traditional metallic brackets with green elastomeric ligatures. Conclusion: Metal appliances were considered very attractive, whereas aligners were classified as less attractive by children and adolescents. The correlation between esthetic perception and socioeconomic status revealed that individuals with a higher socioeconomic level judged esthetics as the most attractive attribute. For those

  9. Ribbon-wise customized lingual appliance and orthodontic anchor screw for the treatment of skeletal high-angle maxillary protrusion without bowing effect.

    Science.gov (United States)

    Inami, Toru; Ito, Goshi; Miyazawa, Ken; Tabuchi, Masako; Goto, Shigemi

    2018-05-02

    This case report demonstrates the treatment of a skeletal Class II high-angle adult patient with bimaxillary protrusion, angle Class I occlusion, and crowded anterior teeth. A ribbon-wise arch wire and a customized lingual appliance with anterior vertical slots were used to achieve proper torque control of the maxillary anterior teeth. An orthodontic anchor screw and a palatal bar were used for vertical control to avoid increasing the Frankfort-mandibular plane angle (FMA) by maxillary molar extrusion. Through the combined use of the ribbon-wise customized lingual appliance, palatal bar, and orthodontic anchor screw, vertical control and an excellent treatment result were achieved without the vertical and horizontal bowing effects peculiar to conventional lingual treatment.

  10. Niobium Titanium and Copper wire samples

    CERN Multimedia

    2009-01-01

    Two wire samples, both for carrying 13'000Amperes. I sample is copper. The other is the Niobium Titanium wiring used in the LHC magnets. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. Magnet coils are made of copper-clad niobium–titanium cables — each wire in the cable consists of 9’000 niobium–titanium filaments ten times finer than a hair. The cables carry up to 12’500 amps and must withstand enormous electromagnetic forces. At full field, the force on one metre of magnet is comparable ...

  11. Premolar root changes following treatment with the banded herbst appliance.

    Science.gov (United States)

    Nasiopoulos, Athanasios T; Athanasiou, Athanasios E; Papadopoulos, Moschos A; Kolokithas, George; Ioannidou, Ioulia

    2006-07-01

    The aim of this prospective study was to radiographically assess root morphology changes in maxillary and mandibular premolars following Herbst appliance treatment. Twenty-five consecutive adolescents (19 boys and six girls, mean age 13.08 years) with Class II, Division 1 malocclusion were treated with the banded Herbst appliance for a mean period of 13.16 months. Periapical radiographs of the upper and lower premolars were obtained before appliance insertion and immediately after appliance removal using the parallel technique. All radiographs were scanned, digitized and analyzed using appropriately adjusted cephalometric software. The pre- and post-treatment length and area of the first and second maxillary and mandibular premolar roots were calculated. Statistical analysis included paired t-tests to evaluate pre- and posttreatment changes, and independent t-tests to compare the pre and post-treatment differences between the first and the second premolars, which served as controls. The level of significance was set at p appliance. We observed a statistically-significant decrease in the root area of the first mandibular premolars compared to that of the second mandibular premolars. Although we observed no statistically-significant root morphology changes in the first and second premolars following Herbst appliance treatment, the mandibular first premolars revealed significantly more root resorption than did the mandibular second premolars.

  12. Service oriented network architecture for control and management of home appliances

    Science.gov (United States)

    Hayakawa, Hiroshi; Koita, Takahiro; Sato, Kenya

    2005-12-01

    Recent advances in multimedia network systems and mechatronics have led to the development of a new generation of applications that associate the use of various multimedia objects with the behavior of multiple robotic actors. The connection of audio and video devices through high speed multimedia networks is expected to make the system more convenient to use. For example, many home appliances, such as a video camera, a display monitor, a video recorder, an audio system and so on, are being equipped with a communication interface in the near future. Recently some platforms (i.e. UPnP1, HAVi2 and so on) are proposed for constructing home networks; however, there are some issues to be solved to realize various services by connecting different equipment via the pervasive peer-to-peer network. UPnP offers network connectivity of PCs of intelligent home appliances, practically, which means to require a PC in the network to control other devices. Meanwhile, HAVi has been developed for intelligent AV equipments with sophisticated functions using high CPU power and large memory. Considering the targets of home alliances are embedded systems, this situation raises issues of software and hardware complexity, cost, power consumption and so on. In this study, we have proposed and developed the service oriented network architecture for control and management of home appliances, named SONICA (Service Oriented Network Interoperability for Component Adaptation), to address these issues described before.

  13. Wire communication engineering

    International Nuclear Information System (INIS)

    Son, Byeong Tae

    1997-02-01

    This book describes wire telecommunication engineering/ It is divided into eleven chapter, which deal with Introduction with development of telecommunication, voice and sound wave and communication network, Telegraphy with summary of telegraphy, code of telegraphy, communication speed, morse and telex, Telephone on structure, circuit and image telephone, Traffic on telecommunication traffic, transmission of line about theory, cable line and loaded cable, carrier communication with carrier telegraphy and carrier telephone, optical communication with types, structure, specialty, laser and equipment, DATA, Mobile telecommunication on summary, mobile telephone, radio paging and digital mobile telecommunication, ISDN with channel of ISDN, and service of ISDN, and design of telecommunication.

  14. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  15. Epitaxial semiconductor quantum wires.

    Science.gov (United States)

    Wu, J; Chen, Y H; Wang, Z G

    2008-07-01

    The investigation on the direct epitaxial quantum wires (QWR) using MBE or MOCVD has been persuited for more than two decades, more lengthy in history as compared with its quantum dot counterpart. Up to now, QWRs with various structural configurations have been produced with different growth methods. This is a reviewing article consisting mainly of two parts. The first part discusses QWRs of various configurations, together with laser devices based on them, in terms of the two growth mechanisms, self-ordering and self-assembling. The second part gives a brief review of the electrical and optical properties of QWRs.

  16. Appliance Displays: Accessibility Challenges and Proposed Solutions.

    Science.gov (United States)

    Fusco, Giovanni; Tekin, Ender; Giudice, Nicholas A; Coughlan, James M

    2015-10-01

    People who are blind or visually impaired face difficulties using a growing array of everyday appliances because they are equipped with inaccessible electronic displays. We report developments on our "Display Reader" smartphone app, which uses computer vision to help a user acquire a usable image of a display and have the contents read aloud, to address this problem. Drawing on feedback from past and new studies with visually impaired volunteer participants, as well as from blind accessibility experts, we have improved and simplified our user interface and have also added the ability to read seven-segment digit displays. Our system works fully automatically and in real time, and we compare it with general-purpose assistive apps such as Be My Eyes, which recruit remote sighted assistants (RSAs) to answer questions about video captured by the user. Our discussions and preliminary experiment highlight the advantages and disadvantages of fully automatic approaches compared with RSAs, and suggest possible hybrid approaches to investigate in the future.

  17. Maxillary molar distalization with first class appliance.

    Science.gov (United States)

    Ramesh, Namitha; Palukunnu, Biswas; Ravindran, Nidhi; Nair, Preeti P

    2014-02-27

    Non-extraction treatment has gained popularity for corrections of mild-to-moderate class II malocclusion over the past few decades. The distalization of maxillary molars is of significant value for treatment of cases with minimal arch discrepancy and mild class II molar relation associated with a normal mandibular arch and acceptable profile. This paper describes our experience with a 16-year-old female patient who reported with irregularly placed upper front teeth and unpleasant smile. The patient was diagnosed to have angles class II malocclusion with moderate maxillary anterior crowding, deep bite of 4 mm on a skeletal class II base with an orthognathic maxilla and retrognathic mandible and normal growth pattern. She presented an ideal profile and so molar distalization was planned with the first-class appliance. Molars were distalised by 8 mm on the right and left quadrants and class I molar relation achieved within 4 months. The space gained was utilised effectively to align the arch and establish a class I molar and canine relation.

  18. 46 CFR 111.60-11 - Wire.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be...

  19. Initial Evaluation of a Titration Appliance for Temporary Treatment of Obstructive Sleep Apnea.

    Science.gov (United States)

    Levendowski, Daniel J; Morgan, Todd; Westbrook, Philip

    2012-01-01

    Custom oral appliances that adjustably advance the mandible provide superior outcomes when treating patients with moderate or severe sleep apnea. Custom appliances, however, are expensive, must be fitted by a dentist, and the likelihood of successful outcomes are difficult to predict. An inexpensive trial appliance, if proven efficacious, might be used to predict custom appliance outcomes or to provide temporary therapeutic benefit. The aim of this initial study was to assess the treatment efficacy of a novel titration oral appliance with that of an optimized custom appliance. Seventeen patients, treated with a custom oral appliance for at least one year, successfully completed a three-night home sleep test. The baseline obstructive sleep apnea severity was established on Night 1 with seven patients exhibiting severe, six moderate and four mild apnea/hypopnea indexes. Patients were randomly assigned to wear their custom appliance or the titration appliance on Nights 2 and 3. Significant reductions in the mean overall and supine apnea indexes (p titration and custom appliances. The proportion of patients who exhibited at least a 50% reduction in the overall apnea index and supine apnea/hypopnea were similar for the titration and custom appliance (~60%). The custom appliance reduced the overall apnea/hypopnea index by 50% in a greater proportion of the patients compared to the titration appliance (77% vs. 53%). The titration appliance significantly reduced the degree of hypoxic exposure across sleep disordered breathing events overall (p titration appliance, but preferred the titration appliance to no therapy. The titration appliance may be useful in assessing oral appliance treatment efficacy. When set to 70% of maximum protrusion, the titration appliance may provide immediate, temporary therapeutic benefit.

  20. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  1. Thermal Testing and Integration: Magnetospheric MultiScale (MMS) Observatories with Digital 1-Wire Sensors

    Science.gov (United States)

    Solimani, Jason A.; Rosanova, Santino

    2015-01-01

    Thermocouples require two thin wires to be routed out of the spacecraft to connect to the ground support equipment used to monitor and record the temperature data. This large number of wires that exit the observatory complicates integration and creates an undesirable heat path during testing. These wires exiting the spacecraft need to be characterized as a thermal short that will not exist during flight. To minimize complexity and reduce thermal variables from these ground support equipment (GSE) wires, MMS pursued a hybrid path for temperature monitoring, utilizing thermocouples and digital 1-wire temperature sensors. Digital 1-wire sensors can greatly reduce harness mass, length and complexity as they can be spliced together. For MMS, 350 digital 1-wire sensors were installed on the spacecraft with only 18 wires exiting as opposed to a potential 700 thermocouple wires. Digital 1-wire sensors had not been used in such a large scale at NASAGSFC prior to the MMS mission. During the MMS thermal vacuum testing a lessons learned matrix was formulated that will assist future integration of 1-wires into thermal testing and one day into flight.

  2. Improved superconducting magnet wire

    Science.gov (United States)

    Schuller, I.K.; Ketterson, J.B.

    1983-08-16

    This invention is directed to a superconducting tape or wire composed of alternating layers of copper and a niobium-containing superconductor such as niobium of NbTi, Nb/sub 3/Sn or Nb/sub 3/Ge. In general, each layer of the niobium-containing superconductor has a thickness in the range of about 0.05 to 1.5 times its coherence length (which for Nb/sub 3/Si is 41 A) with each copper layer having a thickness in the range of about 170 to 600 A. With the use of very thin layers of the niobium composition having a thickness within the desired range, the critical field (H/sub c/) may be increased by factors of 2 to 4. Also, the thin layers of the superconductor permit the resulting tape or wire to exhibit suitable ductility for winding on a magnet core. These compositions are also characterized by relatively high values of critical temperature and therefore will exhibit a combination of useful properties as superconductors.

  3. Process for producing fine and ultrafine filament superconductor wire

    Science.gov (United States)

    Kanithi, Hem C.

    1992-01-01

    A process for producing a superconductor wire made up of a large number of round monofilament rods is provided for, comprising assembling a multiplicity of round monofilaments inside each of a multiplicity of thin wall hexagonal tubes and then assembling a number of said thin wall hexagonal tubes within an extrusion can and subsequently consolidating, extruding and drawing the entire assembly down to the desired wire size.

  4. Wire and Packing Tape Sandwiches

    Science.gov (United States)

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  5. Development of halogen-free, heat-resistant, low-voltage wire for automotive use

    International Nuclear Information System (INIS)

    Ueno, Keiji; Suzuki, Sizuo; Takahagi, Masatoshi; Uda, Ikujiro

    1995-01-01

    The environmental load of our motorized society is of major concern, and includes considerations of recycling of automotive parts as the industrial wastes. The total average length of AV, AVX (electrical wire insulated with PVC, cross-linked PVC), and AEX (electrical wire insulated with cross-linked polyolefin) wires required for the harnesses in modern automobiles is approximately 2,000-3,000 meters per unit. However these electrical wires contain a large amount of halogen, which can generate the smoke and corrosive gas. In response to this problem the authors have developed the electron beam irradiated halogen-free, heat-resistant, low-voltage electrical wire which does not contain any halogen based polymer or flame retardants. The developed wire features the reliability equivalent to AEX wire with minimum environmental load. (Author)

  6. Wire metamaterials: physics and applications.

    Science.gov (United States)

    Simovski, Constantin R; Belov, Pavel A; Atrashchenko, Alexander V; Kivshar, Yuri S

    2012-08-16

    The physics and applications of a broad class of artificial electromagnetic materials composed of lattices of aligned metal rods embedded in a dielectric matrix are reviewed. Such structures are here termed wire metamaterials. They appear in various settings and can operate from microwaves to THz and optical frequencies. An important group of these metamaterials is a wire medium possessing extreme optical anisotropy. The study of wire metamaterials has a long history, however, most of their important and useful properties have been revealed and understood only recently, especially in the THz and optical frequency ranges where the wire media correspond to the lattices of microwires and nanowires, respectively. Another group of wire metamaterials are arrays and lattices of nanorods of noble metals whose unusual properties are driven by plasmonic resonances. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Molecular wires, switches and memories

    Science.gov (United States)

    Chen, Jia

    Molecular electronics, an emerging field, makes it possible to build individual molecules capable of performing functions identical or analogous to present- day conductors, switches, or memories. These individual molecules, with a nano-meter scale characteristic length, can be designed and chemically synthesized with specific atoms, geometries and charge distribution. This thesis focuses on the design, and measurements of molecular wires, and related strategically engineered structures-molecular switches and memories. The experimental system relies on a thermodynamically driven self-assembling process to attach molecules onto substrate surfaces without intervention from outside. The following topics will be discussed: directed nanoscale manipulation of self-assembled molecules using scanning tunneling microscope; investigation on through-bond transport of nanoscale symmetric metal/conjugated self- assembled monolayers (SAM)/metal junctions, where non- Ohmic thermionic emission was observed to be the dominant process, with isocyanide-Pd contacts showing the lowest thermionic barrier of 0.22 eV; the first realization of robust and large reversible switching behavior in an electronic device that utilizes molecules containing redox centers as the active component, exhibiting negative differential resistance (NDR) and large on-off peak-to-valley ratio (PVR); observation of erasable storage of higher conductivity states in these redox- center containing molecular devices, and demonstration of a two-terminal electronically programmable and erasable molecular memory cell with long bit retention time.

  8. New horizons in orthodontics & dentofacial orthopedics: fixed Twin Blocks & TransForce lingual appliances.

    Science.gov (United States)

    Clark, William John

    2011-01-01

    During the 20th century functional appliances evolved from night time wear to more flexible appliances for increased day time wear to full time wear with Twin Block appliances. The current trend is towards fixed functional appliances and this paper introduces the Fixed Twin Block, bonded to the teeth to eliminate problems of compliance in functional therapy. TransForce lingual appliances are pre-activated and may be used in first phase treatment for sagittal and transverse arch development. Alternatively they may be integrated with fixed appliances at any stage of treatment.

  9. Class II malocclusion treatment using combined Twin Block and fixed orthodontic appliances – A case report

    Science.gov (United States)

    Al-Anezi, Saud A.

    2010-01-01

    The effect of the Twin Block functional orthodontic appliances is mostly dento-alveolar with small skeletal effect. There are certain clinical indications where functional appliances can be used successfully in class II malocclusion e.g. in a growing patient. The use of these appliances is greatly dependent on the patient’s compliance and they simplify the fixed appliance phase. In this case, a 13-year old adolescent was treated with Twin Block appliance followed by fixed appliance to detail the occlusion. The design and treatment effects were demonstrated in this case report. PMID:24151413

  10. Electrical appliance energy consumption control methods and electrical energy consumption systems

    Science.gov (United States)

    Donnelly, Matthew K [Kennewick, WA; Chassin, David P [Pasco, WA; Dagle, Jeffery E [Richland, WA; Kintner-Meyer, Michael [Richland, WA; Winiarski, David W [Kennewick, WA; Pratt, Robert G [Kennewick, WA; Boberly-Bartis, Anne Marie [Alexandria, VA

    2008-09-02

    Electrical appliance energy consumption control methods and electrical energy consumption systems are described. In one aspect, an electrical appliance energy consumption control method includes providing an electrical appliance coupled with a power distribution system, receiving electrical energy within the appliance from the power distribution system, consuming the received electrical energy using a plurality of loads of the appliance, monitoring electrical energy of the power distribution system, and adjusting an amount of consumption of the received electrical energy via one of the loads of the appliance from an initial level of consumption to an other level of consumption different than the initial level of consumption responsive to the monitoring.

  11. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    , therefore, we’ve drawn conclusions and recommendations for future editions of the event, also generalizable to other experiences of gamification especially in events. This report details the methodology and working elements from the design phase, human resources and organization of production......This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and have...... proposed new ones (viralization of the event on social networks and improvement of the integration of international attendees). On the other hand we defined a set of research objectives related to the study of gamification in an eminently social place like an event. Most of the goals have been met and...

  12. Analysis of the torque capacity of a completely customized lingual appliance of the next generation

    Science.gov (United States)

    2014-01-01

    Introduction In lingual orthodontic therapy, effective torque control of the incisors is crucial due to the biomechanical particularities associated with the point of force application and the tight link between third order deviations and vertical tooth position. Aim The aim of the present in vitro investigation was to analyze the torque capacity of a completely customized lingual appliance of the next generation (WIN) in combination with different finishing archwire dimensions. Methods Using a typodont of the upper arch carrying the WIN appliance, slot filling and undersized individualized β-titanium archwires were engaged. Horizontal forces ranging from 0 to 100 cN were applied at the central incisor by means of spring gauges. The resulting angular deviations were recorded and the corresponding torque moments were calculated. Results For fullsize archwires (0.018”×0.018” β-titanium and 0.018”×0.025” β-titanium), an initial torque play of 0-2° had to be overcome prior to the development of an effective torque moment. Thereafter, a linear correlation between torque angle and torque moment developed for both archwire dimensions with steeper slopes calculated for the specimens with the larger dimension. A torque moment of 2 Nmm required for effective torque correction was noted after a minimum of 2-3° of twist for the 0.018”×0.018” β-titanium wires as compared to 2-4° for the 0.018”×0.025” β-titanium study sample. When undersized archwires were analyzed (0.0175”×0.0175” β-titanium), the measured torque play ranged from 5-7°. After 8-12° of torque angle, the threshold of 2 Nmm was reached. A linear relationship between twist angle and torque moment in which the steepness of the slopes was generally flatter than the ones calculated for the slot filling archwires was noted. Conclusions Given the high precision of the bracket slot-archwire-combination provided with the WIN appliance, an effective torque control can be clinically

  13. Electronic Control System Of Home Appliances Using Speech Command Words

    Directory of Open Access Journals (Sweden)

    Aye Min Soe

    2015-06-01

    Full Text Available Abstract The main idea of this paper is to develop a speech recognition system. By using this system smart home appliances are controlled by spoken words. The spoken words chosen for recognition are Fan On Fan Off Light On Light Off TV On and TV Off. The input of the system takes speech signals to control home appliances. The proposed system has two main parts speech recognition and smart home appliances electronic control system. Speech recognition is implemented in MATLAB environment. In this process it contains two main modules feature extraction and feature matching. Mel Frequency Cepstral Coefficients MFCC is used for feature extraction. Vector Quantization VQ approach using clustering algorithm is applied for feature matching. In electrical home appliances control system RF module is used to carry command signal from PC to microcontroller wirelessly. Microcontroller is connected to driver circuit for relay and motor. The input commands are recognized very well. The system is a good performance to control home appliances by spoken words.

  14. Nickel ions release in patients with fixed orthodontic appliances.

    Science.gov (United States)

    Levrini, L; Lusvardi, G; Gentile, D

    2006-03-01

    The extent to which orthodontic appliances can cause contact allergies due to nickel release is a controversial matter. Since the data provided by literature are contrasting, the Authors think that it is important to analyse nickel ions released in organic tissues by means of a plasma spectrometer. About 100 intact hairs were taken from 15 patients wearing fixed orthodontic appliances. The hairs had been washed 12 to 24 h before, in order to limit environmental contamination. The same procedure was carried out on a control group corresponding in sex, age and abode. The samples of hair were taken from at least 3 different scalp sites: frontal, vertex and occipital areas. According to the spectrophotometric analysis of the hair, there were no differences in nickel concentrations between the test group (0.50 mg/g on average) and control group (0.64 mg/g) (*Pnickel concentration was found in the control sample (without orthodontic appliances) to a maximum of 2.20 mg/g. This suggests that environmental contamination, in particular diet, has an influence on ion concentration. Other studies also confirm that gut absorption of nickel released in the mouth by orthodontic appliances is much lower than the absorption of nickel release through diet. It can be assumed that orthodontic appliances do not release significant values of nickel to be a risk factor to the patient's health.

  15. Status Checking System of Home Appliances using machine learning

    Directory of Open Access Journals (Sweden)

    Yoon Chi-Yurl

    2017-01-01

    Full Text Available This paper describes status checking system of home appliances based on machine learning, which can be applied to existing household appliances without networking function. Designed status checking system consists of sensor modules, a wireless communication module, cloud server, android application and a machine learning algorithm. The developed system applied to washing machine analyses and judges the four-kinds of appliance’s status such as staying, washing, rinsing and spin-drying. The measurements of sensor and transmission of sensing data are operated on an Arduino board and the data are transmitted to cloud server in real time. The collected data are parsed by an Android application and injected into the machine learning algorithm for learning the status of the appliances. The machine learning algorithm compares the stored learning data with collected real-time data from the appliances. Our results are expected to contribute as a base technology to design an automatic control system based on machine learning technology for household appliances in real-time.

  16. The influnece of the partial single reduction on mechanical properties wires made from trip steel with 0,43 % C

    Directory of Open Access Journals (Sweden)

    S. Wiewiórowska

    2015-01-01

    Full Text Available Large strain inhomogeneity is caused by the shape of deformation zone of die and by the friction between tool and deformed wire for multistage wire drawing processes. The influence on the value of the redundant strain by the use of different partial single reductions during all wire drawing process was observed. This problem is particularly important for TRIP steel wires drawing processes because the strain intensity influences on the speed of retained austenite transformation into martensite.

  17. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  18. Orthodontic Wire Ingestion during Treatment: Reporting a Case and Review the Management of Foreign Body Ingestion or Aspiration (Emergencies

    Directory of Open Access Journals (Sweden)

    Mohammad Hoseini

    2013-01-01

    Full Text Available Today orthodontic treatment is in growing demand and is not limited to a specific age or social group. The nature of orthodontic treatment is such that the orthodontic wires and appliances, which are used to apply force and move the teeth, are exposed to the oral cavity. Shaping and replacing these wires in oral cavity are the major assignments of orthodontist on appointments. Therefore, we can say that orthodontic treatment requires working with dangerous tools in a sensitive place like oral cavity which is the entrance of respiratory and digestive systems. In this paper, a case of ingesting a broken orthodontic wire during eating is reported, and also necessary remedial measures at the time of encountering foreign body ingestion or aspiration are provided.

  19. Assessment of Literature Related to Combustion Appliance Venting Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rapp, V. H.; Less, B. D.; Singer, B. C.; Stratton, J. C.; Wray, C. P.

    2015-02-01

    In many residential building retrofit programs, air tightening to increase energy efficiency is often constrained by safety concerns with naturally vented combustion appliances. Tighter residential buildings more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spill combustion exhaust into the living space. Several measures, such as installation guidelines, vent sizing codes, and combustion safety diagnostics, are in place with the intent to prevent backdrafting and combustion spillage, but the diagnostics conflict and the risk mitigation objective is inconsistent. This literature review summarizes the metrics and diagnostics used to assess combustion safety, documents their technical basis, and investigates their risk mitigations. It compiles information from the following: codes for combustion appliance venting and installation; standards and guidelines for combustion safety diagnostics; research evaluating combustion safety diagnostics; research investigating wind effects on building depressurization and venting; and software for simulating vent system performance.

  20. Wire Array Solar Cells: Fabrication and Photoelectrochemical Studies

    Science.gov (United States)

    Spurgeon, Joshua Michael

    Despite demand for clean energy to reduce our addiction to fossil fuels, the price of these technologies relative to oil and coal has prevented their widespread implementation. Solar energy has enormous potential as a carbon-free resource but is several times the cost of coal-produced electricity, largely because photovoltaics of practical efficiency require high-quality, pure semiconductor materials. To produce current in a planar junction solar cell, an electron or hole generated deep within the material must travel all the way to the junction without recombining. Radial junction, wire array solar cells, however, have the potential to decouple the directions of light absorption and charge-carrier collection so that a semiconductor with a minority-carrier diffusion length shorter than its absorption depth (i.e., a lower quality, potentially cheaper material) can effectively produce current. The axial dimension of the wires is long enough for sufficient optical absorption while the charge-carriers are collected along the shorter radial dimension in a massively parallel array. This thesis explores the wire array solar cell design by developing potentially low-cost fabrication methods and investigating the energy-conversion properties of the arrays in photoelectrochemical cells. The concept was initially investigated with Cd(Se, Te) rod arrays; however, Si was the primary focus of wire array research because its semiconductor properties make low-quality Si an ideal candidate for improvement in a radial geometry. Fabrication routes for Si wire arrays were explored, including the vapor-liquid-solid growth of wires using SiCl4. Uniform, vertically aligned Si wires were demonstrated in a process that permits control of the wire radius, length, and spacing. A technique was developed to transfer these wire arrays into a low-cost, flexible polymer film, and grow multiple subsequent arrays using a single Si(111) substrate. Photoelectrochemical measurements on Si wire array

  1. Assessment of Literature Related to Combustion Appliance Venting Systems

    Energy Technology Data Exchange (ETDEWEB)

    Rapp, Vi H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Stratton, Chris [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Wray, Craig P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-06-01

    In many residential building retrofit programs, air tightening to increase energy efficiency is constrained by concerns about related impacts on the safety of naturally vented combustion appliances. Tighter housing units more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spillage. Several test methods purportedly assess the potential for depressurization-induced backdrafting and spillage, but these tests are not robustly reliable and repeatable predictors of venting performance, in part because they do not fully capture weather effects on venting performance. The purpose of this literature review is to investigate combustion safety diagnostics in existing codes, standards, and guidelines related to combustion appliances. This review summarizes existing combustion safety test methods, evaluations of these test methods, and also discusses research related to wind effects and the simulation of vent system performance. Current codes and standards related to combustion appliance installation provide little information on assessing backdrafting or spillage potential. A substantial amount of research has been conducted to assess combustion appliance backdrafting and spillage test methods, but primarily focuses on comparing short-term (stress) induced tests and monitoring results. Monitoring, typically performed over one week, indicated that combinations of environmental and house operation characteristics most conducive to combustion spillage were rare. Research, to an extent, has assessed existing combustion safety diagnostics for house depressurization, but the objectives of the diagnostics, both stress and monitoring, are not clearly defined. More research is also needed to quantify the frequency of test “failure” occurrence throughout the building stock and assess the statistical effects of weather (especially wind) on house depressurization and in turn on combustion appliance venting

  2. Management of anterior dental crossbite with removable appliances

    Directory of Open Access Journals (Sweden)

    Ayca Tuba Ulusoy

    2013-01-01

    Full Text Available This case report describes the treatment of an 8-year-old girl with anterior dental crossbite using a series of removable appliances to bring the teeth into a normal position. Clinical presentation and intervention: A removable acrylic appliance with a bite plate incorporating a screw was used to correct the anterior dental crossbite and align the incisors. The subsequent eruption of the maxillary left lateral incisor on the palatinal side was treated with a second acrylic plate incorporating a labiolingual spring. After an 8-month period, the anterior crossbite involving multiple incisors was corrected.

  3. International comparison of product certification and verification methods for appliances

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Romankiewicz, John [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fridley, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Zheng, Nina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-06-01

    Enforcement of appliance standards and consumer trust in appliance labeling are important foundations of growing a more energy efficient economy. Product certification and verification increase compliance rates which in turn increase both energy savings and consumer trust. This paper will serve two purposes: 1) to review international practices for product certification and verification as they relate to the enforcement of standards and labeling programs in the U.S., E.U., Australia, Japan, Canada, and China; and 2) to make recommendations for China to implement improved certification processes related to their mandatory standards and labeling program such as to increase compliance rates and energy savings potential.

  4. International Comparison of Product Certification and Verification Methods for Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Nan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Romankiewicz, John [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fridley, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Zheng, Nina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-06-01

    Enforcement of appliance standards and consumer trust in appliance labeling are important foundations of growing a more energy efficient economy. Product certification and verification increase compliance rates which in turn increase both energy savings and consumer trust. This paper will serve two purposes: 1) to review international practices for product certification and verification as they relate to the enforcement of standards and labeling programs in the U.S., E.U., Australia, Japan, Canada, and China; and 2) to make recommendations for China to implement improved certification processes related to their mandatory standards and labeling program such as to increase compliance rates and energy savings potential.

  5. Orthodontic parotitis: a rare complication from an orthodontic appliance.

    Science.gov (United States)

    McCarthy, Eileen; Cobb, Alistair R M

    2012-12-01

    A case is presented of a 14-year-old female undergoing orthodontic fixed appliance treatment who presented with right facial swelling in the parotid region. An initial diagnosis of acute infective parotitis was made by her primary care clinician. However, after clinical examination and ultrasonographic imaging, a diagnosis of salivary stasis secondary to inflammatory occlusion of Stensen's ductal orifice was made. The ductal orifice had been traumatized by the adjacent orthodontic appliance. This has not been described before in the literature. The differential diagnosis of parotid enlargement in children is discussed.

  6. X-ray backlighting density measurements of tungsten and aluminum wire and wire array z-pinches

    International Nuclear Information System (INIS)

    Hammer, D.A.; Pikuz, S.A.; Shelkovenko, T.A.; Greenly, J.B.; Sinars, D.B.; Mingaleev, A.R.

    1999-01-01

    Calibrated density measurements in both the coronal plasmas and dense cores of exploding W wire and wire array Z-pinches, powered by the ∼450 kA, 100 ns XP-pulser at Cornell University, have been made using two-frame x-ray backlighting in conjunction with known thickness W step wedges. The backlighting images are made by Mo wire X-pinch radiation filtered by 12.5 microm Ti impinging upon a sandwich of films (Micrat VR, Kodak GWL, Kodak DEF) which have different sensitivities to increase the dynamic range of the method. A W step wedge filter is placed in front of the films, giving absolute line density calibration of each exposure with estimated errors ranging from 20 to 50%. Assuming x-ray absorption by the W plasma is the same as for the solid material, the authors are able to measure W areal densities from 3.2 x 10 19 to 2 x 10 17 /cm 2 . These can be converted to number density assuming azimuthal symmetry. For example, for an exploded 7.5 microm wire with a 15--20 microm diameter dense core and a 1 mm corona diameter, the implied W volume density ranges from 2x10 18 to over 10 22 /cm 3 . Integration of the line density gives an estimate of the fraction of the wire mass in the corona and core. For example, with 100 kA peak current in a single 7.5 microm W wire, ∼70% (>90%) of the W mass is in the corona after 53 ns (61 ns). The authors also observe that the corona has large, roughly axisymmetric axial nonuniformity both in radius and in mass density. In addition, the coronal plasma contains more of the W mass, expands faster and is more uniform when the wire is surface-cleaned by preheating. In arrays of 2--8 wires with the same 100 kA total current, detectable coronal plasma appears after 25--35 ns, and much of it is swept toward the center of the array, forming a dense channel. The portion of the initial wire mass in the coronal plasma increases with smaller wire diameter and decreases with greater wire number: 15% for 4 x 13.5 microm, 35% for 4 x 7

  7. Procool - eco-efficient cold appliances for the commercial use

    International Nuclear Information System (INIS)

    Schaeppi, Bernd; Ritter, Herbert; Barthel, Claus; Hermann, Laurenz; Streif, Oswald

    2005-01-01

    Pro-Cool is an EU-wide demonstration project which supports the development and market penetration of eco-efficient plug-in cold appliances for the commercial use. These products should be both highly energy efficient, free of HFC-containing refrigerants and -foaming agents and eco-efficient in a general sense. Thus the project corresponds with the EU Integrated Product Policy which aims at improving products by considering the ecological impact along the product life cycle. Besides ecological criteria, which are central for the project, other aspects relevant for purchasers like warranty and functionality are taken into account to guarantee the acceptance of the products by the demand side target groups. The so called 'voice of the customer' has been considered in the development of the criteria To achieve the necessary stimulation of the supply and demand side market a combined competition and procurement approach is developed addressing both manufacturers and buyers respectively users of the products. The central measure of the project is a European competition for suppliers what offers leading manufacturers of the market the opportunity to present themselves as innovative companies which provide eco-efficient equipment. Eight leading manufacturers which have a high market share in the selected product categories are taking part in the competition. Furthermore three large companies representing the demand side branches of super market chains and drinks industry already have signed a general agreement to support the project and to consider the products resulting from the competition in their procurement activities. Thus major supply and demand side target groups which are capable to support market transformation have joined the project. The competition terminates by December 2005 and the award of the winning products takes place in spring 2006 at an international fair or conference event. The paper presents the objectives and the concept of the project. Relevant

  8. Accuracy in tooth positioning with a fully customized lingual orthodontic appliance.

    Science.gov (United States)

    Grauer, Dan; Proffit, William R

    2011-09-01

    To understand orthodontic tooth movement, a method of quantification of tooth position discrepancies in 3 dimensions is needed. Brackets and wires now can be fabricated by CAD/CAM technology on a setup made at the beginning of treatment, so that treatment should produce a reasonably precise duplicate of the setup. The extent of discrepancies between the planned and actual tooth movements can be quantified by registration of the setup and final models. The goal of this study was to evaluate the accuracy of a CAD/CAM lingual orthodontic technique. Dental casts of 94 consecutive patients from 1 practice, representing a broad range of orthodontic problems, were scanned to create digital models, and then the setup and final models for each patient were registered individually for the maxillary and mandibular dental arches. Individual tooth discrepancies between the setup and actual outcome were computed and expressed in terms of a six-degrees-of-freedom rectangular coordinate system. Discrepancies in position and rotation between the setup and outcome were small for all teeth (generally less than 1 mm and 4°) except for the second molars, where some larger discrepancies were observed. Faciolingual expansion in the posterior teeth was greater in the setup than in the final models, especially at the second molars. Linear mixed models showed that age, type of tooth, jaw, initial crowding, time in slot-filling wire, use of elastics, days in treatment, interproximal reduction, and rebonding, were all influences on the final differences, but, for most of these factors, the influence was small, explaining only a small amount of the discrepancy between the planned and the actual outcomes. These fully customized lingual orthodontic appliances were accurate in achieving the goals planned at the initial setup, except for the full amount of planned expansion and the inclination at the second molars. This methodology is the first step toward understanding and measuring tooth

  9. Numerical Investigation of Corrugated Wire Mesh Laminate

    Directory of Open Access Journals (Sweden)

    Jeongho Choi

    2013-01-01

    Full Text Available The aim of this work is to develop a numerical model of Corrugated Wire Mesh Laminate (CWML capturing all its complexities such as nonlinear material properties, nonlinear geometry and large deformation behaviour, and frictional behaviour. Development of such a model will facilitate numerical simulation of the mechanical behaviour of the wire mesh structure under various types of loading as well as the variation of the CWML configuration parameters to tailor its mechanical properties to suit the intended application. Starting with a single strand truss model consisting of four waves with a bilinear stress-strain model to represent the plastic behaviour of stainless steel, the finite element model is gradually built up to study single-layer structures with 18 strands of corrugated wire meshes consistency and double- and quadruple-layered laminates with alternating crossply orientations. The compressive behaviour of the CWML model is simulated using contact elements to model friction and is compared to the load-deflection behaviour determined experimentally in uniaxial compression tests. The numerical model of the CWML is then employed to conduct the aim of establishing the upper and lower bounds of stiffness and load capacity achievable by such structures.

  10. Results of the Fermilab wire production program

    International Nuclear Information System (INIS)

    Strauss, B.P.; Remsbottom, R.H.; Reardon, P.J.; Curtis, C.W.; McDonald, W.K.

    1976-01-01

    In examining the various schedules of wire drawing and heat treating, the Critchlow type of schedule provided the highest and most uniform data from billet to billet. It consists of a long anneal at 400 +- 20 0 C at a cold work point giving about 99 percent reduction in area from the extrusion size. Several quick copper anneals at 300 0 C may be interspersed to aid in fabrication. A final anneal at finished size both peaks up the resistivity ratio of the copper as well as the critical current of the alloy by moving dislocations to subcell walls. Using this method, critical currents of 1.7 x 10 5 A/cm 2 could be maintained in all billets. The copper cladding and sinking method looks promising and should save production costs. In spite of this, it was important to attain good packing density in the billets to assure uniform filament pattern and reduce breakage in wire drawing. Overall, a procedure was found for fabricating wire in large production lots that would be acceptable for constructing dipole magnets. It is felt that this method could be peaked up with time

  11. Reliability of the wire drawing dies

    International Nuclear Information System (INIS)

    Sheikh, A.K.; Khany, S.E.

    1993-01-01

    A wear based model is proposed for the dies used in wire drawing process. Using this wear model, it is possible to predict life of the die corresponding to a wear limit criterion. Since various quantities in the model are random in nature the resulting die life will also be random quantity characterized by an appropriate distribution. Using a probabilistic characterization of the parameters of the predictive model, Monte Carlo simulations were conducted to establish the die life distribution. To asses the sensitivity of life distribution with respect to various contributing variables (parameters), the simulation runs were conducted at different levels of these variables (parameters). It is shown that wire drawing die life is Weibull distributed. To compare the simulated results with actual time to failure, data of dies was obtained from a large wire drawing company and was compared with corresponding scenario generated by Monte Carlo simulation. Results obtained by Monte Carlo simulations were very close to the actual time to failure data. (author)

  12. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems. Electrical wiring shall be installed and maintained to conform to SAE J1292—Automobile, Truck, Truck-Tractor...

  13. Modeling birds on wires.

    Science.gov (United States)

    Aydoğdu, A; Frasca, P; D'Apice, C; Manzo, R; Thornton, J M; Gachomo, B; Wilson, T; Cheung, B; Tariq, U; Saidel, W; Piccoli, B

    2017-02-21

    In this paper we introduce a mathematical model to study the group dynamics of birds resting on wires. The model is agent-based and postulates attraction-repulsion forces between the interacting birds: the interactions are "topological", in the sense that they involve a given number of neighbors irrespective of their distance. The model is first mathematically analyzed and then simulated to study its main properties: we observe that the model predicts birds to be more widely spaced near the borders of each group. We compare the results from the model with experimental data, derived from the analysis of pictures of pigeons and starlings taken in New Jersey: two different image elaboration protocols allow us to establish a good agreement with the model and to quantify its main parameters. We also discuss the potential handedness of the birds, by analyzing the group organization features and the group dynamics at the arrival of new birds. Finally, we propose a more refined mathematical model that describes landing and departing birds by suitable stochastic processes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  15. Composite conductor containing superconductive wires

    Energy Technology Data Exchange (ETDEWEB)

    Larson, W.L.; Wong, J.

    1974-03-26

    A superconductor cable substitute made by coworking multiple rods of superconductive niobium--titanium or niobium--zirconium alloy with a common copper matrix to extend the copper and rods to form a final elongated product which has superconductive wires distributed in a reduced cross-section copper conductor with a complete metallurgical bond between the normal-conductive copper and the superconductor wires contained therein is described. The superconductor cable can be in the form of a tube.

  16. Drawing on international experience to reform the Belgian market for ostomy appliances.

    Science.gov (United States)

    Simoens, Steven; Van den Steen, Dirk; Vanleene, Veerle; De Maré, Luc; Moldenaers, Ingrid; Debruyne, Hans; Ramaekers, Dirk

    2007-02-01

    This article aims to review the regulatory framework governing the Belgian ostomy appliance market in the light of the experience of Denmark, France, the Netherlands and Ontario (Canada) with regulation of ostomy appliances. Information about the regulatory framework was derived from the international literature, analysis of legal texts and a survey completed by national experts. The comparative analysis revealed that these countries have adopted varying approaches towards regulating their domestic ostomy appliance market. Strategies to keep down prices include public procurement in Denmark, maximum prices in France and exclusion of expensive appliances from reimbursement in the Netherlands. To contain public expenditure on ostomy appliances, consumption patterns are monitored in the Netherlands, the quantity of reimbursed appliances is limited in Belgium and public reimbursement is restricted in Ontario. Ostomy appliances are generally distributed by community pharmacies and medical equipment shops. In countries that emphasise home care delivery such as Denmark, domiciliary distributors dominate the market to the detriment of community pharmacies which do not seem to be able to offer this service at a competitive price. An avenue for reforming the Belgian ostomy appliance market is proposed which valorizes the role of ostomy care nurses in guiding the choice of ostomy appliances. Furthermore, it is recommended that a competitive tendering process determines the price of ostomy appliances, that reimbursement for service provision by distributors is separated from reimbursement of appliances, and that patients receive a fixed grant from the third-party payer to buy ostomy appliances.

  17. Three case reports demonstrating treatment of relatively complex orthodontic cases using a completely customised lingual appliance.

    Science.gov (United States)

    Buckley, John

    2016-01-01

    It is a commonly held misconception among Irish dentists that only minor malocclusions can be treated with lingual appliances. This article demonstrates the use of contemporary completely customised lingual orthodontic appliances to treat a diverse range of malocclusions, to a satisfactory level, and thereby may disabuse clinicians of the belief that only minor malocclusions can be treated with lingual appliances.

  18. 30 CFR 75.701-4 - Grounding wires; capacity of wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...

  19. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  20. Finite element simulation of impact response of wire mesh screens

    Directory of Open Access Journals (Sweden)

    Wang Caizheng

    2015-01-01

    Full Text Available In this paper, the response of wire mesh screens to low velocity impact with blunt objects is investigated using finite element (FE simulation. The woven wire mesh is modelled with homogeneous shell elements with equivalent smeared mechanical properties. The mechanical behaviour of the woven wire mesh was determined experimentally with tensile tests on steel wire mesh coupons to generate the data for the smeared shell material used in the FE. The effects of impacts with a low mass (4 kg and a large mass (40 kg providing the same impact energy are studied. The joint between the wire mesh screen and the aluminium frame surrounding it is modelled using contact elements with friction between the corresponding elements. Damage to the screen of different types compromising its structural integrity, such as mesh separation and pulling out from the surrounding frame is modelled. The FE simulation is validated with results of impact tests conducted on woven steel wire screen meshes.

  1. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  2. Measures for improving the adoption of higher efficiency appliances in Indonesian households: An analysis of lifetime use and decision-making in the purchase of electrical appliances

    International Nuclear Information System (INIS)

    Wijaya, Muhammad Ery; Tezuka, Tetsuo

    2013-01-01

    Highlights: ► We observe human psychosocial variables regarding purchase of electrical appliances. ► Two cities with different cultures are subject of this study – Bandung and Yogyakarta. ► Differences in the lifetime of appliances can be attributed to the cultural. ► Ads and store’s staff have the greatest impact on people’s choice of appliances. ► Adoption of higher-efficiency appliances could be implemented based on each culture. - Abstract: One approach to decreasing electricity consumption is to facilitate the replacement of older appliances with new, higher-efficiency. The objectives of this paper are to compare and analyse the replacement of appliances in two cities of Indonesia – Yogyakarta and Bandung – that are characterised by different cultural backgrounds, ethnicities, and decision-making processes in the household purchase of electrical appliances. A questionnaire survey method was employed to obtain information on behavioural economics and human psychosocial variables such as attitudes, beliefs and perceived benefits regarding the replacement and purchase of electrical appliances. The results show that refrigerators in Yogyakarta have a longer lifetime than in Bandung. However, in Bandung, air conditioners, electric fans, rice cookers, and water pumps have a longer lifetime than in Yogyakarta. These differences in the lifetime of appliances can be attributed to the cultural differences within the two cities that are reflected in the manner in which people use electrical appliances as well as to their lack of knowledge regarding appliance operation. An analysis of the factors influencing the purchase of appliances indicated that people in Yogyakarta show a greater awareness of the benefits of adopting higher-efficiency appliances than do persons in Bandung. The following suggestions could be implemented to improve the strategy of encouraging the adoption of higher-efficiency appliances: (1) in Yogyakarta, energy labelling could be

  3. Comparative distalization effects of Jones jig and pendulum appliances.

    Science.gov (United States)

    Patel, Mayara Paim; Janson, Guilherme; Henriques, José Fernando Castanha; de Almeida, Renato Rodrigues; de Freitas, Marcos Roberto; Pinzan, Arnaldo; de Freitas, Karina Maria Salvatore

    2009-03-01

    In this study, we compared the dentoalveolar changes of Class II patients treated with Jones jig and pendulum appliances. The experimental group comprised 40 Class II malocclusion subjects, divided into 2 groups: group 1 consisted of 20 patients (11 boys, 9 girls) at a mean pretreatment age of 13.17 years, treated with the Jones jig appliance for 0.91 years; group 2 comprised 20 patients (8 boys, 12 girls) at a mean pretreatment age of 13.98 years, treated with the pendulum appliance for 1.18 years. Only active treatment time of molar distalization was evaluated in the predistalization and postdistalization lateral cephalograms. Molar, second premolar, and incisor angular and linear variables were obtained. The intergroup treatment changes in these variables were compared with independent t tests. The maxillary second premolars showed greater mesial tipping and extrusion in the Jones jig group, indicating more anchorage loss during molar distalization with this appliance. The amounts and the monthly rates of molar distalization were similar in both groups. The Jones jig group showed greater mesial tipping and extrusion of the maxillary second premolars. The mean amounts and the monthly rates of first molar distalization were similar in both groups.

  4. 33 CFR 81.20 - Lights and sound signal appliances.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Lights and sound signal appliances. 81.20 Section 81.20 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY INTERNATIONAL NAVIGATION RULES 72 COLREGS: IMPLEMENTING RULES Exemptions § 81.20 Lights and sound signal...

  5. The effect of orthodontic extraoral appliances on depression and the ...

    African Journals Online (AJOL)

    2013-04-11

    Apr 11, 2013 ... [10] found similar results indicating that the. The effect of orthodontic extraoral appliances on depression and the anxiety levels of patients and parents. T Topcuoglu, O Yildirim1, M Birlik2, O Sokucu3, M Semiz4. Private Orthodontics, Mersin, 1Department of Psychiatry, School of Medicine, University of Abant ...

  6. Low-power Appliance Recognition using Recurrent Neural Networks

    NARCIS (Netherlands)

    Rizky Pratama, Azkario; Simanjuntak, Frans Juanda; Lazovik, Aliaksandr; Aiello, Marco

    2018-01-01

    Indoor energy consumption can be understood by breaking overall power consumption down into individual components and appliance activations. The clas- sification of components of energy usage is known as load disaggregation or ap- pliance recognition. Most of the previous efforts address the

  7. Do soft drinks affect metal ions release from orthodontic appliances?

    Science.gov (United States)

    Mikulewicz, Marcin; Wołowiec, Paulina; Loster, Bartłomiej W; Chojnacka, Katarzyna

    2015-01-01

    The effect of orange juice and Coca Cola(®) on the release of metal ions from fixed orthodontic appliances. A continuous flow system designed for in vitro testing of orthodontic appliances was used. Orange juice/Coca Cola(®) was flowing through the system alternately with artificial saliva for 5.5 and 18.5h, respectively. The collected samples underwent a multielemental ICP-OES analysis in order to determine the metal ions release pattern in time. The total mass of ions released from the appliance into orange juice and Coca Cola(®) (respectively) during the experiment was calculated (μg): Ni (15.33; 37.75), Cr (3.604; 1.052), Fe (48.42; ≥ 156.1), Cu (57.87, 32.91), Mn (9.164; 41.16), Mo (9.999; 30.12), and Cd (0.5967; 2.173). It was found that orange juice did not intensify the release of metal ions from orthodontic appliances, whereas Coca Cola(®) caused increased release of Ni ions. Copyright © 2015 Elsevier GmbH. All rights reserved.

  8. Customer service in appliance sales departments of selected ...

    African Journals Online (AJOL)

    For some time now, researchers across the world have therefore shown particular interest in service quality as an indication of retailers' service excellence. This research investigated the customer service in appliance sales departments in prominent retail stores in Tshwane, RSA in three phases to involve different role ...

  9. 49 CFR 238.230 - Safety appliances-new equipment.

    Science.gov (United States)

    2010-10-01

    ... form of an industry-wide standard and at a minimum shall: (1) Identify the type(s) of car to which the... or supports considered part of the car body. Safety appliance brackets or supports will be considered part of the car body and will not be required to be mechanically fastened to the piece of passenger...

  10. Compatibility of fixed orthodontic appliances with MR environment

    Czech Academy of Sciences Publication Activity Database

    Starčuk jr., Zenon; Hubálková, H.; Starčuková, Jana; Linetskiy, I.; Bartušek, Karel; Krupa, P.

    2006-01-01

    Roč. 19, Suppl. 1 (2006), EPOS 726:1-7 E-ISSN 1352-8661 R&D Projects: GA MZd NR8110 Institutional research plan: CEZ:AV0Z20650511 Keywords : orthodontic appliance * magnetic resonance * compatibility * dentistry * artifact Subject RIV: FS - Medical Facilities ; Equipment Impact factor: 0.756, year: 2005 http://posters.webges.com/esmrmb/epos

  11. Toothbrushing forces in children with fixed orthodontic appliances.

    Science.gov (United States)

    Heasman, P A; MacGregor, I D; Wilson, Z; Kelly, P J

    1998-08-01

    The aim of this investigation was to determine whether toothbrushing forces are influenced by wearing fixed orthodontic appliances. Thirty children, (10 males, 20 females) with planned fixed appliance therapy and aged 10-15 years, were recruited to the study. No subject had previously worn an orthodontic appliance. At baseline, each subject brushed their teeth in their usual way, unsupervised. The toothbrush used was a purpose-designed electronic instrument that measured the force applied to the brush and transmitted force data by radio to a remote PC. After toothbrushing, subjects had orthodontic brackets fitted. Toothbrushing was repeated at 2 and 14 weeks after baseline, and brushing forces recorded. There were no significant differences between the measurements made at baseline and those made at 2 and 14 weeks. There were no differences between males and females in the forces used at any time point. It was concluded that toothbrushing forces are unaffected by placing fixed orthodontic appliances in children. The brushing forces recorded were comparable with those previously found by other investigators.

  12. Determining the Relationship between the Use of Fixed Appliances ...

    African Journals Online (AJOL)

    Mike Saghiri

    2011-10-07

    Oct 7, 2011 ... 3Department of Orthodontic, Director of Orthosurgery Fellowship, Dental School, Shaheed Beheshti University of. Medical Sciences, Tehran ... Fixed appliances for orthodontic treatment increased the potential of gingival bleeding and Hyperplasia. .... youngsters, but does not leave long term destruction on.

  13. Refrigeration Controls: Electrical & Mechanical; Appliance Repair 3: 9027.02.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This booklet outlines a course designed to equip major appliance service students with the fundamental knowledge and understanding of procedures, basic electrical circuitry, and nomenclatures of components necessary in successfully tracing a circuit and repairing or replacing a malfunctioning component. Course content includes goals, specific…

  14. Energy conservation opportunities in commercial appliances. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Hurley, J.R.; Searight, E.F.; Wong, A.

    1978-12-01

    This study establishes a data base of energy-consuming appliances in the commercial sector, and identifies and rates the most-promising development opportunities that would save significant amounts of energy on a national level. A detailed national inventory of 45 major appliances and their energy consumption was established for the year 1975. Thirty-four potential appliance improvements were identified, evaluated, and ranked. The opportunities are identified by means of a literature search and contact with industry representatives. The commercial sector is defined in terms of the divisions prescribed in the S.I.C. Manual (1972) of the OMB. These groups are recombined into the commercial subsectors of communications; utilities; wholesale; retail; finance, insurance, real estate, and services; hospital; schools; and public administration. The major energy-consuming appliances in the following six functional-use categories were identified: space heating and cooling; water heating; refrigeration; cooking; and lighting. The equipment in these categories was estimated to consume 87% of the total energy used in the commercial sector, with the remaining 13% consumed by equipment such as computers, business machines, laundry equipment, dishwashing, and other food-service equipment. (MCW)

  15. Estimation of Release of Nickel and Chromium by Indian Made Orthodontic Appliance in Saliva.

    Science.gov (United States)

    Parashar, Sandeep; Maurya, Rajkumar; Gupta, Ankur; Hegde, Chatura; Anand, Neelima

    2015-09-01

    With increasing use of Indian made orthodontic materials, need was felt to know nickel and chromium release from these material. This study was conducted on simulated appliances consisting of brackets (022″Roth, Modern orthodontics, Ludhiana, India), from second premolar to central incisor, buccal tube and 0.019×0.025- inch SS arch wires secured with SS ligatures. Immersion was done in artificial saliva. Samples were analysed to using Atomic Absorption Photospectrometer (GVC ScientificEquipment Pvt. Ltd Australia) at AES Laboratories (P) Ltd., Noida India on 1(st), 7(th), 14(th) and 28(th) day. SPSS (ver 17, Inc., Chicago, Illinois, USA) was used toperform the statistical analysis. Descriptive statistics i.e. median and 25 and75 percentiles were used. Peak nickel release was on 7(th) day and subsequently declined over 14(th) and 28(th) day. The peak level of chromium concentration was on 14(th) day, which declined thereafter. Average daily release of nickel and chromium over a period of one month was 97.368 μg/day and 47.664 μg/day respectively. The estimated release rates were approximately 32% and 16% of the reported average daily dietary.

  16. The influence of the manufacturing method on the microstructure and drawing properties of copper wires

    International Nuclear Information System (INIS)

    Gruber, A.; Jeglitsch, F.

    1982-01-01

    Copper is the third most important common metal from production figures after iron and aluminium and is largely used as pure metal in the electroindustry mainly here in the form of wires of different sizes due to its excellent electrical properties. Therefore all factors influencing the drawing ability are very important. The following work deals with the influence of impurity measurements as well as of the microstructure on the deformation or recrystallization behaviour in manufacturing continuous casting and rolling wire and dip-forming wire, and gives a rupture cause specific to each manufacturing method in the wire drawing process. (orig.) [de

  17. Studies of IBL wire bonds operation in a ATLAS-like magnetic field.

    CERN Document Server

    Alvarez Feito, D; Mandelli, B

    2015-01-01

    At the Large Hadron Collider (LHC) experiments, most of silicon detectors use wire bonds to connect front-end chips and sensors to circuit boards for the data and service trans- missions. These wire bonds are operated in strong magnetic field environments and if time varying currents pass through them with frequencies close to their mechanical resonance frequency, strong resonant oscillations may occur. Under certain conditions, this effect can lead to fatigue stress and eventually breakage of wire bonds. During the first LHC Long Shutdown, the ATLAS Pixel Detector has been upgraded with the addition of a fourth innermost layer, the Insertable B-Layer (IBL), which has more than 50000 wire bonds operated in the ATLAS 2 T magnetic field. The results of systematic studies of operating wire bonds under IBL-like conditions are presented. Two different solutions have been investigated to minimize the oscillation amplitude of wire bonds.

  18. Modeling of GE Appliances: Cost Benefit Study of Smart Appliances in Wholesale Energy, Frequency Regulation, and Spinning Reserve Markets

    Energy Technology Data Exchange (ETDEWEB)

    Fuller, Jason C.; Parker, Graham B.

    2012-12-31

    This report is the second in a series of three reports describing the potential of GE’s DR-enabled appliances to provide benefits to the utility grid. The first report described the modeling methodology used to represent the GE appliances in the GridLAB-D simulation environment and the estimated potential for peak demand reduction at various deployment levels. The third report will explore the technical capability of aggregated group actions to positively impact grid stability, including frequency and voltage regulation and spinning reserves, and the impacts on distribution feeder voltage regulation, including mitigation of fluctuations caused by high penetration of photovoltaic distributed generation. In this report, a series of analytical methods were presented to estimate the potential cost benefit of smart appliances while utilizing demand response. Previous work estimated the potential technical benefit (i.e., peak reduction) of smart appliances, while this report focuses on the monetary value of that participation. The effects on wholesale energy cost and possible additional revenue available by participating in frequency regulation and spinning reserve markets were explored.

  19. Clinical and mechanical factors associated with the removal of temporary epicardial pacemaker wires after cardiac surgery.

    Science.gov (United States)

    Elmistekawy, Elsayed; Gee, Yen-Yen; Une, Dai; Lemay, Matthieu; Stolarik, Anne; Rubens, Fraser D

    2016-01-16

    Temporary pacemaker wires are placed in the majority of patients after cardiac surgery. There is no information on mechanical factors related to wire removal. Clinical information related to temporary wire use and removal was prospectively collected from a large cardiac surgical unit over one year. Measurements of maximal tension that nurses and doctors would apply to remove temporary wires was determined using a hand-held portable scale. In a prospective trial, patients (n = 41) had their wires extracted in series to the portable scale to determine the maximal tension required for safe removal. Ventricular wires were placed in 86.5 % of patients during the observed year. Pacing facilitated weaning from CPB in over 15 % of patients and pacer dependence was seen in 2.1 %. No patients suffered major complications after wire removal. There was no difference in the tension that physicians or nurses would apply to comfortably extract temporary wires. In the prospective trial, there was no difference in the tension required for removal of atrial or ventricular wires (atrial 18.3 ± 17.9 oz versus 14.5 ± 14.2 oz, p = 0.430). There were no patient factors that correlated with the degree of resistance and there was no significant difference between the tension required to remove wires with (21.0 ± 22.5 oz) or without (14.1 ± 5.1 oz) an atrial button. Temporary epicardial wire removal is innocuous and was not associated with any complications. In some patients tension required for safe removal exceeded 20 ounces. Strategies to standardize wire removal may prevent complications and may minimize unnecessary wire retention.

  20. Wire array z-pinch insights for high x-ray power generation

    International Nuclear Information System (INIS)

    Sanford, T.W.L.; Mock, R.C.; Marder, B.M.

    1998-08-01

    The discovery that the use of very large numbers of wires enables high x-ray power to be generated from wire-array z-pinches represents a breakthrough in load design for large pulsed power generators, and has permitted high temperatures to be generated in radiation cavities on Saturn and Z. In this paper, changes in x-ray emission characteristics as a function of wire number, array mass, and load radius, for 20-mm-long aluminum arrays on Saturn that led to these breakthrough hohlraum results, are discussed and compared with a few related emission characteristics of high-wire-number aluminum and tungsten arrays on Z. X=ray measurement comparisons with analytic models and 2-D radiation-magnetohydrodynamic (RMHC) code simulations in the x-y and r-z planes provide confidence in the ability of the models and codes to predict future x-ray performance with very-large-number wire arrays

  1. Wire array z-pinch insights for high X-ray power generation

    Energy Technology Data Exchange (ETDEWEB)

    Sanford, T.W.L.; Marder, B.M.; Desjarlais, M.P. [and others

    1998-12-31

    The discovery that the use of very large numbers of wires enables high x-ray power to be generated from wire-array z-pinches represents a breakthrough in load design for large pulsed power generators, and has permitted high temperatures to be generated in radiation cavities on Saturn and Z. In this paper, changes in x-ray emission characteristics as a function of wire number, array mass, and load radius, for 20-mm-long aluminum arrays on Saturn that led to these breakthrough hohlraum results, are discussed and compared with a few related emission characteristics of high-wire-number aluminum and tungsten arrays on Z. X-ray measurement comparisons with analytic models and 2-D radiation-magnetohydrodynamic (RMHC) code simulations in the x-y and r-z planes provide confidence in the ability of the models and codes to predict future x-ray performance with very-large-number wire arrays.

  2. Wire array z-pinch insights for high x-ray power generation

    Energy Technology Data Exchange (ETDEWEB)

    Sanford, T.W.L.; Mock, R.C.; Nash, T.J. [and others

    1998-08-01

    The discovery that the use of very large numbers of wires enables high x-ray power to be generated from wire-array z-pinches represents a breakthrough in load design for large pulsed power generators, and has permitted high temperatures to be generated in radiation cavities on Saturn. In this paper, changes in x-ray emission characteristics as a function of wire number, array mass, and load radius, for 20-mm-long aluminum arrays on Saturn that led to these breakthrough hohlraum results, are discussed and compared with a few related emission characteristics of high-wire-number aluminum and tungsten arrays on Z. X=ray measurement comparisons with analytic models and 2-D radiation-magnetohydrodynamic (RMHC) code simulations in the x-y and r-z planes provide confidence in the ability of the models and codes to predict future x-ray performance with very-large-number wire arrays.

  3. Wire array z-pinch insights for high x-ray power generation

    Energy Technology Data Exchange (ETDEWEB)

    Sanford, T.W.L.; Mock, R.C.; Marder, B.M. [and others

    1997-12-31

    The discovery that the use of very large numbers of wires enables high x-ray power to be generated from wire-array z-pinches represents a breakthrough in load design for large pulsed power generators, and has permitted high temperatures to be generated in radiation cavities on Saturn and Z. In this paper, changes in x-ray emission characteristics as a function of wire number, array mass, and load radius, for 20-mm-long aluminum arrays on Saturn that led to these breakthrough hohlraum results, are discussed and compared with a few related emission characteristics of high-wire-number aluminum and tungsten arrays on Z. X-ray measurement comparisons with analytic models and 2-D radiation-magnetohydrodynamic (RMHC) code simulations in the x-y and r-z planes provide confidence in the ability of the models and codes to predict future x-ray performance with very-large-number wire arrays.

  4. Wire array z-pinch insights for high X-ray power generation

    International Nuclear Information System (INIS)

    Sanford, T.W.L.; Marder, B.M.; Desjarlais, M.P.

    1998-01-01

    The discovery that the use of very large numbers of wires enables high x-ray power to be generated from wire-array z-pinches represents a breakthrough in load design for large pulsed power generators, and has permitted high temperatures to be generated in radiation cavities on Saturn and Z. In this paper, changes in x-ray emission characteristics as a function of wire number, array mass, and load radius, for 20-mm-long aluminum arrays on Saturn that led to these breakthrough hohlraum results, are discussed and compared with a few related emission characteristics of high-wire-number aluminum and tungsten arrays on Z. X-ray measurement comparisons with analytic models and 2-D radiation-magnetohydrodynamic (RMHC) code simulations in the x-y and r-z planes provide confidence in the ability of the models and codes to predict future x-ray performance with very-large-number wire arrays

  5. [A comparative study on three-dimensional movement of anterior teeth between applying MDD appliances and applying three common fixed appliances in the initial alignment stage].

    Science.gov (United States)

    Hu, Bo; Song, Jinlin; Wu, Peng; He, Ping; Deng, Feng; Gao, Xiang

    2013-10-01

    Typodont models of bilateral canines gingival displaced vertically for 3 mm and bilateral lateral incisors palatal displaced horizontally for 3 mm are made and every kind of the two kind models was divided into four groups: MDD, MBT, self-ligating and Tip-Edge. Each group of the two kinds of models had 5 models, so a total of 40 models for the two kinds of models were set up. The experimental models were aligned with a 0.30 mm of nickel titanium round wire in a water-bath with constant temperature 45 degrees C for 30 minutes. The three-dimensional digital images of the experimental models before and after the water bath were obtained by scanning with the three dimensional optical scanner ATOS. Geomagic software was used to overlap the digital images taken before and after the water bath treatment. The vertical changes of sign points of canines, the movements of sign points of lateral incisors in the sagittal plane and the horizontal plane were quantified by using the Color map. The data was then processed by a two-factor analysis of variance by using SAS 9.2 software package. Analysis of the results shows that the vertical changes of sign points of canines , the movements of sign points of lateral incisors in the sagittal plane and the horizontal plane of MDD group are all less than those in the other three groups, a statistically significant difference (P teeth displacement is directly related to the size of orthodontic force on the typodont models. Thus the preliminary results suggest that MDD appliance might have advantages of light force in the alignment stage, and that the possible relevant factors are the improvement of its sub-slot and the single ligation wing design.

  6. Preparation of Cu, Ag, Fe and Al nanoparticles by the exploding wire ...

    Indian Academy of Sciences (India)

    We describe a novel process for the production of nanoparticles of Cu, Ag, Fe and Al which involves exploding their respective wires, triggered by large current densities in the wires. The particles are characterised by X-ray diffraction (XRD) and atomic force microscopy (AFM). Particle sizes in the range 20-100nm were ...

  7. Electron Lens as Beam-Beam Wire Compensator in HL-LHC

    CERN Document Server

    Valishev, A

    2013-01-01

    Current wires are considered for compensation of long-range beam-beam interactions for the High Luminosity upgrade (HL-LHC) of the Large Hadron Collider at CERN. In this note, we demonstrate the advantage of using Electron Lens for this purpose instead of a conventional current-bearing wire.

  8. Correction of a Overjet and Overbite In Class II Division 1 Malocclusion Using Twin Block Appliance Therapy: A Case Report.

    Science.gov (United States)

    Shastri, Dipti; Tandon, Pradeep; Singh, Gulshan K; Singh, Alka; Sharma, Sudhir

    2015-01-01

    Class II division 1 malocclusion is the most common malocclusion. It shows specific clinical characteristics such as large overiet and deep overbite resulting in a soft tissue profile imbalance. Majority of the patients with class II division 1 malocclusions have an underlying skeletal discrepancy between the maxilla and mandible. The treatment of skeletal class II division 1 malocclusion is done taking into consideration the age, growth potential, severity of malocclusion, and compliance of patient with treatment. Myofunctional appliances can be successfully used to treat growing patients with class II division 1 malocclusion. This article presents a discussion on successful treatment of class II division 1 malocclusion with growth modification approach using twin block appliances.

  9. Social perceptions of adults wearing orthodontic appliances: a cross-sectional study.

    Science.gov (United States)

    Jeremiah, H G; Bister, D; Newton, J T

    2011-10-01

    This study ascertained the influence of orthodontic appliances on subjective ratings for social competence (SC), intellectual ability (IA), psychological adjustment (PA), and attractiveness in young adult orthodontic patients. A cross-sectional analytical questionnaire study was conducted with 130 undergraduates from the UK. Each participant was asked to look at a single, randomly assigned colour photograph of a young adult female and then asked to make judgements concerning her personal characteristics. Five modified photographs of the same young adult female were used: (1) no appliance, (2) stainless steel fixed orthodontic appliance, (3) ceramic fixed orthodontic appliance, (4) gold fixed orthodontic appliance, and (5) clear colourless aligner. Likert scales with higher scores indicating more positive ratings were used. The results were analysed using chi-square test, one-way univariate analysis of variance, and post hoc Tukey-B and Kruskal-Wallis tests. The results showed that greater perceived IA was associated with the appearance of no appliance (mean values: 7.56) rather than steel (6.67) or ceramic appliances (6.65) but similar to the gold (7.35) and aligner (7.08) appliances. No significant differences between the different orthodontic appliance appearances were found for SC and PA. A trend existed where the no appliance image (resembling a lingual appliance) or clear aligner was considered more attractive than the visible buccal fixed appliances. In the absence of other information, the judgements an individual young adult makes concerning the personal characteristics of a young adult are influenced by dental appearance and orthodontic appliance design. This may influence orthodontic appliance choice.

  10. In vitro immunotoxic and genotoxic activities of particles emitted from two different small-scale wood combustion appliances

    Science.gov (United States)

    Tapanainen, Maija; Jalava, Pasi I.; Mäki-Paakkanen, Jorma; Hakulinen, Pasi; Happo, Mikko S.; Lamberg, Heikki; Ruusunen, Jarno; Tissari, Jarkko; Nuutinen, Kati; Yli-Pirilä, Pasi; Hillamo, Risto; Salonen, Raimo O.; Jokiniemi, Jorma; Hirvonen, Maija-Riitta

    2011-12-01

    Residential wood combustion appliances emit large quantities of fine particles which are suspected to cause a substantial health burden worldwide. Wood combustion particles contain several potential health-damaging metals and carbon compounds such as polycyclic aromatic hydrocarbons (PAH), which may determine the toxic properties of the emitted particles. The aim of the present study was to characterize in vitro immunotoxicological and chemical properties of PM 1 ( Dp ≤ 1 μm) emitted from a pellet boiler and a conventional masonry heater. Mouse RAW264.7 macrophages were exposed for 24 h to different doses of the emission particles. Cytotoxicity, production of the proinflammatory cytokine TNF-α and the chemokine MIP-2, apoptosis and phases of the cell cycle as well as genotoxic activity were measured after the exposure. The type of wood combustion appliance had a significant effect on emissions and chemical composition of the particles. All the studied PM 1 samples induced cytotoxic, genotoxic and inflammatory responses in a dose-dependent manner. The particles emitted from the conventional masonry heater were 3-fold more potent inducers of programmed cell death and DNA damage than those emitted from the pellet boiler. Furthermore, the particulate samples that induced extensive DNA damage contained also large amounts of PAH compounds. Instead, significant differences between the studied appliances were not detected in measurements of inflammatory mediators, although the chemical composition of the combustion particles differed considerably from each other. In conclusion, the present results show that appliances representing different combustion technology have remarkable effects on physicochemical and associated toxicological and properties of wood combustion particles. The present data indicate that the particles emitted from incomplete combustion are toxicologically more potent than those emitted from more complete combustion processes.

  11. Losses of new type HTS wires with transposed Bi-2223 filaments; Fuiramento ten'igata Bi-2223 tashin senzai no sonshitsu tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Watabe, K.; Yamashita, K.; Sumiyoshi, F. [Kagoshima Univ., Kagoshima (Japan); Hayashi, H.; Irie, F. [Kyushu Electric Power Co. Inc., Fukuoka (Japan)

    2000-05-29

    In Bi-2223 multifilamentary wire, large hysteresis loss occurs by 'self-magnetic field effect' where transport current flows on the surface. To prevent from this, uniformity of transport current distribution by filament transposition is effective. Round wire with two layers of helical coil around Ag core material by four Bi-2223 multifilamentary wires was fabricated as trial. Uniform condition of current distribution was explored and twist angle was found to be an important parameter. Hysteresis loss of wound wire in a reverse direction was reduced by 1/3 compared with one of wound wire in a same direction and known wire. (NEDO)

  12. Wire Rupture Optimization in Wire Electrical Discharge Machining using Taguchi Approach

    Directory of Open Access Journals (Sweden)

    Maher Ibrahem

    2017-01-01

    Full Text Available Wire electrical discharge machining (WEDM is one of the most important nontraditional machining process that is well-known for cutting difficult to machine materials. The wire electrode along with machining parameters control the WEDM process. This research work focuses on optimizing WEDM parameters using Taguchi technique to minimize wire rupture. Experiments have been done using the L18 orthogonal array. Each experiment is repeated three times to ensure accurate readings of the wire rupture. The statistical methods of signal to noise ratio (S/N ratio is applied to study effects of peak current, pulse width, charging time, wire speed, and wire tension on wire rupture. As a results, the peak current, pulse width, and wire tension have the most significant effect on wire rupture followed by charging time and wire speed. The developed analysis can be used in the metal cutting field to identify the optimum machining parameters for less wire rupture.

  13. Enhancing wire-composite bond strength of bonded retainers with wire surface treatment.

    Science.gov (United States)

    Oesterle, L J; Shellhart, W C; Henderson, S

    2001-06-01

    Bonded orthodontic retainers with wires embedded in composite resin are commonly used for orthodontic retention. The purpose of this study was to test, in vitro, various wire surface treatments to determine the optimal method of enhancing the wire-composite bond strength. Coaxial wires and stainless steel wires with different surface treatments were bonded to bovine enamel and then pulled along their long axes with an Instron universal testing machine. Wire surface treatments included placing a right-angle bend in the wire, microetching the wire, and treating the wire with adhesion promoters; combinations of treatments were also examined. The results demonstrated a 24-fold increase in the wire-composite bond strength of wire that was microetched (sandblasted), compared with that of untreated straight wire. The difference between the amount of force required to break the bond produced by microetching alone (246.1 +/- 46.0 MPa) and that required for the bonds produced by the retentive bend (87.8 +/- 16.3 MPa), the adhesion promoters (silane, 11.0 +/- 3.1 MPa; Metal Primer, 28.5 +/- 15.8 MPa), or for any combination of surface treatments, was statistically significant. Microetching a stainless steel wire produced a higher wire-composite bond strength than that obtained from a coaxial wire (113.5 +/- 27.5 MPa). The results of this study indicate that microetching or sandblasting a stainless steel wire significantly increases the strength of the wire-composite bond.

  14. Effects of dynamic-demand-control appliances on the power grid frequency

    Science.gov (United States)

    Tchuisseu, E. B. Tchawou; Gomila, D.; Brunner, D.; Colet, P.

    2017-08-01

    Power grid frequency control is a demanding task requiring expensive idle power plants to adapt the supply to the fluctuating demand. An alternative approach is controlling the demand side in such a way that certain appliances modify their operation to adapt to the power availability. This is especially important to achieve a high penetration of renewable energy sources. A number of methods to manage the demand side have been proposed. In this work we focus on dynamic demand control (DDC), where smart appliances can delay their switchings depending on the frequency of the system. We introduce a simple model to study the effects of DDC on the frequency of the power grid. The model includes the power plant equations, a stochastic model for the demand that reproduces, adjusting a single parameter, the statistical properties of frequency fluctuations measured experimentally, and a generic DDC protocol. We find that DDC can reduce small and medium-size fluctuations but it can also increase the probability of observing large frequency peaks due to the necessity of recovering pending task. We also conclude that a deployment of DDC around 30-40% already allows a significant reduction of the fluctuations while keeping the number of pending tasks low.

  15. Release of metal ions from orthodontic appliances by in vitro studies: a systematic literature review.

    Science.gov (United States)

    Mikulewicz, Marcin; Chojnacka, Katarzyna

    2011-03-01

    In the present work, a systematic literature review on release of metal ions from orthodontic appliances under in vitro conditions is described. Detailed and schematic analysis of used materials and applied methods (immersion media, incubation time, temperature, and analytical techniques) is provided. The PubMed search identified 40 studies, among which eight met the selection criteria. One additional study was included in the review. All the authors agreed that the doses of released metal ions were far below the toxic level and the dietary intake. Although the concentrations of metal ions in immersion media greatly differed, the general conclusions were coherent. It must be underlined that the main disadvantage of in vitro tests was that the experimental setup did not reflect in vivo conditions, e.g., the presence of biofilm, which grows on the surface of the materials in oral cavity. The presence and activity of microflora to a large extent is responsible for the process of corrosion, in particular, biodeterioration. The further scheme of in vitro research should incorporate changeable conditions of oral cavity environment (pH, dynamic conditions-saliva flow) and the presence of microbiological flora (microbiological attack) in the experimental design and, first of all, the real proportions of appliance elements.

  16. Efficiency, behavior, and clinical properties of superelastic NiTi versus multistranded stainless steel wires: a prospective clinical trial.

    Science.gov (United States)

    Sandhu, Satpal S; Shetty, V Surendra; Mogra, Subraya; Varghese, Joseph; Sandhu, Jasleen; Sandhu, Jagpreet S

    2012-09-01

    To investigate efficiency, behavior, and properties of superelastic NiTi vs multistranded stainless steel wires in Begg and preadjusted edgewise appliance (PEA) under moderate to severe crowding conditions. Ninety-six participants (48 male, 48 female), aged 12-18 years old (mean age  =  15.2 ± 1.95), with moderate (≤ 6 mm; mean  =  5.3 ± 0.48) to severe (> 6 mm; mean  =  7.9 ± 0.66) initial crowding were distributed into four groups: superelastic NiTi PEA (n  =  24), superelastic NiTi Begg (n  =  24), multistranded (coaxial) stainless steel PEA (n  =  25), and multistranded (coaxial) stainless steel Begg (n = 23). In this study, 0.16-inch superelastic (austenitic active) NiTi and 0.175-inch multistranded (six stranded, coaxial) stainless steel wires were used in a 0.022-inch slot (Roth prescription) PEA and Begg appliance with a follow-up of six weeks. Analysis of variance revealed no significant difference in reduction of crowding between superelastic NiTi PEA and multistranded (coaxial) stainless steel PEA groups, but reduction in crowding was significantly greater in the superelastic NiTi Begg group compared with the multistranded (coaxial) stainless steel Begg group with F (3, 44)  =  8.896, P NiTi performed significantly better than multistranded (coaxial) stainless steel wire in the Begg appliance. However, in PEA, there was no significant difference.

  17. Hot-wire assisted atomic layer deposition of Tungsten films

    NARCIS (Netherlands)

    Yang, Mengdi

    2018-01-01

    This thesis aims to establish a novel technique of atomic layer deposition (ALD) for the future ultra-large-scale integration (ULSI) of microelectronics. We developed a hot-wire assisted ALD (HWALD), where a heated tungsten (W) filament is utilized instead of a plasma to generate radicals. HWALD is

  18. Reducing Electricity Demand Peaks by Scheduling Home Appliances Usage

    DEFF Research Database (Denmark)

    Rossello Busquet, Ana; Kardaras, Georgios; Iversen, Villy Bæk

    2011-01-01

    . On the contrary, the low priority devices have to pause their operation, when the algorithm dictates it, and resume it in the future. This can become beneficial for both energy companies and users. The electricity suppliers companies will be capable of regulating power generation during demand peaks periods....... Moreover, users can be granted lower electricity bill rates for accepting delaying the operation of some of their appliances. In order to analyze this scenario, teletraffic engineering theory, which is used in evaluating the performance of telecommunication networks, is used. A reversible fair scheduling......Nowadays there is a tendency to consume electricity during the same period of the day leading to demand peaks. Regular energy consumption habits lead to demand peaks at specific temporal intervals, because users consume power at the same time. In order to avoid demand peaks, users’ appliances...

  19. Comparison of Jones jig molar distalization appliance with extraoral traction.

    Science.gov (United States)

    Haydar, S; Uner, O

    2000-01-01

    In this study, 20 patients were evaluated. Ten were treated with intraoral distalization followed by fixed appliance therapy, and 10 were treated with extra oral traction followed by fixed appliance therapy. Molar relationship correction was achieved in 2.5 months with intraoral distalization and in 10.7 months with extraoral distalization. A significant anterior movement of the anchorage unit (P <.001) was observed with the intraoral distalization and a significant distal drift of premolars was observed in the headgear group (P <.05). Palatal plane was found to tip downward significantly in the headgear group (P <.05). Total outcome of the 2 methods were discussed evaluating the advantages and disadvantages of the 2 distalization methods.

  20. Hoisting appliances and fuel handling equipment at nuclear facilities

    International Nuclear Information System (INIS)

    1987-01-01

    The guide is followed by the Finnish Centre for Radiation and Nuclear Safety (STUK) in regulating hoisting and handling equipment Class 3 at nuclear facilities. The guide is applied e.g. to the following equipment: reactor building overhead cranes, hoisting appliances at nuclear fuel storages, fuel handling machines, other hoisting appliances, which because of nuclear safety aspects are classified in Safety Class 3, and load-bearing devices connected with the above equipment, such as replaceable hoisting tools and auxiliary lifting devices. The regulating of hoisting and handling equipment comprises the following stages: handling of preliminary and final safety analysis reports, inspection of the construction plan, supervision of fabrication and construction inspection, and supervision of initial start-up and commissioning inspection

  1. Analysis appliance by gamma tomography with focused collimators

    International Nuclear Information System (INIS)

    Stoddart, H.F.

    1978-01-01

    This invention concerns nuclear medicine and specifically an image-forming appliance providing a very sensitive quantitative determination and the localization in space of the radioactivity of a body organ such as the brain of a patient to whom a substance labelled with radioactive isotopes has been administered. The characteristics of this appliance, which forms an image in a transversal scanning field by means of radioactive isotope radiations, includes several highly focused collimators, placed in line and focused inwards so that they form an arrangement that surrounds a given scanning field. Each collimator is mobile with respect to the adjacent collimator and a system moves the collimators so that the focus of each one uniformly samples at least a half of the total scanning field corresponding to a cross section. The number of detectors is an even one between two and twenty four, and the collimators are twelve in number [fr

  2. Application of SMA technology to auxiliary functions in appliances

    Science.gov (United States)

    Johnson, Bart; Brei, Diann E.; Patera, John

    2002-07-01

    Traditionally smart material actuation has been reserved for high technology industries such as space and aerospace; however, as the field matures more and more instances are found in low-cost, high production areas. This paper describes one such instance - the application of shape memory alloys to auxiliary functions in appliances. This investigation focused on lid locks for washing machines because it is representative of several other applications found in appliances including valves, dispensers, locks, brakes, etc. Several competing concepts for SMA actuated lid locks are discussed including simple analytical design models and experimental characterization of proof-of-concept prototypes. A comparison of these designs based on performance (force, response times), energy (power requirements) and economic metrics is given. From this study, a final concept was developed based upon the best attributes of the different concepts. The resulting proof-of-concept prototype demonstrated improved performance over the current state with a potential for cost reduction.

  3. CE APPROVAL IN ELECTRICAL HOUSEHOLD APPLIANCES AND A CASE STUDY

    Directory of Open Access Journals (Sweden)

    Nazmi EKREN

    2009-01-01

    Full Text Available Due to the reason for rapidly developing technology, increasing competition medium, and awareness of the consumers, nowadays, the exigency of production with good quality has gained more and more significance. Certification of the quality and safety of the products to the consumers is compulsory in terms of producers. There are some documents to certify safety of the products. One of them is CE certificate. In this paper, basic information about CE mark is given and CE standards and tests required for electrical household appliances are mentioned. As an application, one of an electrical household appliance, toaster grill is treated and examined. To obtain CE certificate for toaster grill, required tests are made according to EN60335-2-9 and CE certificate is obtained.

  4. Computation of radiation from wire antennas on conducting bodies

    DEFF Research Database (Denmark)

    Albertsen, N. Christian; Hansen, Jesper; Jensen, Niels E.

    1974-01-01

    A theoretical formulation, in terms of combined magnetic and electric field integral equations, is presented for the class of electromagnetic problems in which one or more wire antennas are connected to a conducting body of arbitrary shape. The formulation is suitable for numerical computation...... provided that the overall dimensions of the structure are not large compared to the wavelength. A computer program is described, and test runs on various configurations involving a cylindrical body with one or more straight wires are presented. The results obtained agree well with experimental data....

  5. Shape of a clamped stiff harpsichord wire driven at a resonant frequency

    Science.gov (United States)

    Hanson, Roger J.; Macomber, Hilliard Kent; Boucher, Mathew A.

    2002-05-01

    A wire transversely driven by a sinusoidal force at the resonant frequency of a vibrational mode vibrates at the driving frequency and at harmonics generated by nonlinear processes in the wire. If the amplitude of a harmonic is measured as a function of position along the wire, its shape is revealed. It differs significantly from a sinusoid in the vicinity of either end of the wire because the ends are clamped and the wire has significant stiffness. The shapes of various harmonics have been determined for a brass harpsichord wire, 70 cm long, from optical detector measurements made at different distances from a clamped end. Knowledge of shape facilitates the determination of antinode amplitudes of harmonics when the gross motion of the wire is so large that the detectors must be positioned near an end of the wire because of their very limited dynamic range. Some observations of harmonics and related phenomena were reported previously [Hanson et al., J. Acoust Soc. Am. 108, 2592 (2000); 106, 2141 (1999)]. The shape information is also needed to help separate nonlinear effects possibly occurring in the detectors from those of interest, occurring in the wire itself.

  6. Synthesis of chemical vapor deposition graphene on tantalum wire for supercapacitor applications

    Energy Technology Data Exchange (ETDEWEB)

    Li, Mingji, E-mail: limingji@163.com [Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electronics Information Engineering, Tianjin University of Technology, Tianjin 300384 (China); Guo, Wenlong [Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electronics Information Engineering, Tianjin University of Technology, Tianjin 300384 (China); Li, Hongji, E-mail: hongjili@yeah.net [Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384 (China); Xu, Sheng [School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072 (China); Qu, Changqing; Yang, Baohe [Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electronics Information Engineering, Tianjin University of Technology, Tianjin 300384 (China)

    2014-10-30

    Highlights: • The capacitance of graphene/tantalum (Ta) wire electrodes is firstly reported. • Graphene was grown on the Ta surface by hot-filament chemical vapor deposition. • Graphene/Ta wire structure is favorable for fast ion and electron transfer. • The graphene/Ta wire electrode shows high capacitive properties. - Abstract: This paper studies the synthesis and electrochemical characterization of graphene/tantalum (Ta) wires as high-performance electrode material for supercapacitors. Graphene on Ta wires is prepared by the thermal decomposition of methane under various conditions. The graphene nanosheets on the Ta wire surface have an average thickness of 1.3–3.4 nm and consist typically of a few graphene monolayers, and TaC buffer layers form between the graphene and Ta wire. A capacitor structure is fabricated using graphene/Ta wire with a length of 10 mm and a diameter of 0.6 mm as the anode and Pt wire of the same size as the cathode. The electrochemical behavior of the graphene/Ta wires as supercapacitor electrodes is characterized by cyclic voltammetry, galvanostatic charge/discharge, and electrochemical impedance spectroscopy in 1 M Na{sub 2}SO{sub 4} aqueous electrolyte. The as-prepared graphene/Ta electrode has highest capacitance of 345.5 F g{sup −1} at current density of 0.5 A g{sup −1}. The capacitance remains at about 84% after 1000 cycles at 10 A g{sup −1}. The good electrochemical performance of the graphene/Ta wire electrode is attributed to the unique nanostructural configuration, high electrical conductivity, and large specific surface area of the graphene layer. This suggests that graphene/Ta wire electrode materials have potential applications in high-performance energy storage devices.

  7. Torque resistance of different stainless steel wires commonly used for fixed retainers in orthodontics.

    Science.gov (United States)

    Arnold, Dario T; Dalstra, Michel; Verna, Carlalberta

    2016-06-01

    Movements of teeth splinted by fixed retention wires after orthodontic treatment have been observed. The aetiological factors for these movements are unknown. The aim of this in vitro study was to compare the resistance to torque of different stainless steel wires commonly used for fixed retainers in orthodontics. Torquing moments acting on a retainer wire were measured in a mechanical force testing system by applying buccal crown torque to an upper lateral incisor in both a 3-teeth and in a 2-teeth setup. Seven stainless steel wires with different shape, type (plain, braided, coaxial, or chain) and dimensions were selected for this study. For a torquing angle of 16.2° in the 3-teeth setup torsion moments can vary between 390 cNmm and 3299 cNmm depending on the retainer wire. For the 2-teeth setup the torsion moments are much smaller. Exposure to the flame of a butane-gas torch for 10 seconds to anneal the wire reduces the stiffness of the retainer wire. Clinicians must select wires for fixed retainers very carefully since the difference in resistance to torque is large. A high level of torque control can be achieved with a plain 0.016 × 0.016-inch or a braided 0.016 × 0.022-inch stainless steel wire. A tooth attached by a retainer wire to only one neighbouring tooth is less resistant to torque than a tooth connected to two neighbouring teeth. Annealing a retainer wire with a flame reduces the stiffness of the wire markedly and can lead to a non-uniform and non-reproducible effect.

  8. Appliance of geochemical engineering in radioactive waste disposal

    International Nuclear Information System (INIS)

    Li Shuang; Zhang Chengjiang; Ni Shijun; Li Kuanliang

    2008-01-01

    The basic foundation of applying geochemical engineering to control environment, common engineering models of disposal radioactive waste and the functions of the engineering barriers are introduced in this paper. The authors take the geochemical engineering barrier materiel research of a radioactive waste repository as an example to explain the appliance of geochemical engineering in the disposal of radioactive waste. And the results show that it can enhance the security of the nuclear waste repository if we use geochemical engineering barrier. (authors)

  9. Evaluation of photo-activation appliances used in dentistry

    Directory of Open Access Journals (Sweden)

    Thales Ribeiro de Magalhães Filho

    2008-01-01

    Full Text Available Objective: Verify the Vickers microhardness promoted by three photo-activation appliances: one Halogen Light Ultralux (Dabi-Atlante, Ribeirão Preto, Brazil and two Light Emitting Diodes. One with a larger diode (Ultraled, Dabi-Atlante, Ribeirão Preto, Brazil and the other with seven smaller diodes (Ultraled xp, Dabi-Atlante, Ribeirão Preto, Brazil in composites with different matrixes. Methods: Three test specimens were made for each resinous materials using silicone molds measuring 4 X 8 X 30 mm. Polymerization was performedin three stages and on the two surfaces. After having been submitted to careful polishing with sequential abrasive papers and diamond paste, the Vickers microhardness of the test specimens was determined. Afterwards these values were submitted to statistical analysis by the ANOVA table and Student’s-t test. Results: The microhardness values obtained in the hybrid composite were as follows: 51.63 kg/mm2 +- 3.27; 52.22 kg/mm2 +- 3.3; 38.08 kg/mm2 +-0.31 and in the ormocer, 41.87 kg/mm2 +- 2.36; 41.5 kg/mm2 +- 1.2; 33.63 kg/mm2 +- 1.2, by the Ultralux (Dabi-Atlante, Ribeirão Preto, Brazil, Ultraled xp (Dabi-Atlante, Ribeirão Preto, Brazil and Ultraled (Dabi-Atlante, Ribeirão Preto, Brazil appliances, respectively. Conclusion: The Ultraled (Dabi-Atlante, Ribeirão Preto, Brazil and Ultraled xp (Dabi-Atlante, Ribeirão Preto, Brazil appliances promoted microhardness values that were similar between them and higher than the values produced by Ultraled (Dabi-Atlante, Ribeirão Preto, Brazil in the composites. It was verified that the intensity of the photo-activator appliances is directly related to the microhardness they produce in the composites.

  10. Evaluation of Musculoskeletal Disorders in Household Appliances Manufacturing Company

    Directory of Open Access Journals (Sweden)

    Aioob Ghanbary

    2015-12-01

    Full Text Available Work-related musculoskeletal disorders are the most prevalent work-related disorders and injuries and being the main cause of disability. This study was conducted to assessment of the prevalence of musculoskeletal disorders in worker company household appliances production. Posture analysis was evaluated by OWAS method and prevalence of musculoskeletal disorders by Nordic questionnaire. With evaluating musculoskeletal disorders among company household appliances production can intervention action to reduce musculoskeletal disorders was carried out. This cross-sectional study was performed on 100 workers of the appliance manufacturing industry. These Individuals were included 15 persons from foam injection workshop, 17 persons from molding workshop, 17 operators of presses, 17 persons from packaging, 17 person from cutting unit and 17 operators of rivet. The Nordic questionnaire was completed by Individuals for the organs of arm, back, leg and wrist and Posture analysis was performed by OWAS method. The data were analyzed using Spss software version 18 and descriptive statistics and Anova test. Nordic questionnaire results revealed that highest disorders were observed in the arm (25%, back (22% and leg (21%. Also Anova test showed that was observed a significant correlation respectively between age and work experience with the prevalence of musculoskeletal disorders (p<0.02 (p<0.01. The results showed based on the level of risk OWAS for each job respectively, the highest level of risk associated with foam injection unit, packaging and cutting unit (risk level 4 and the lowest level of risk associated with molding workshop unit (risk level 2.The results of this study showed that household appliances Manufacturing workers due to the nature of their jobs are at risk of musculoskeletal disorders and Ergonomic interventions to do such as workstation redesign, reduced working hours, cycle of rest-work development.

  11. Put Your Cable Wiring to the Test.

    Science.gov (United States)

    Day, C. William

    2001-01-01

    Discusses why schools and universities should use testing procedures in any wire bid specification for cable wiring and also know how experienced the installers are in testing and installing structured cabling systems. Key cabling terms are included. (GR)

  12. Realizing potential savings of energy and emissions from efficient household appliances in India

    International Nuclear Information System (INIS)

    Parikh, Kirit S.; Parikh, Jyoti K.

    2016-01-01

    The paper projects households' stock of four major electricity consuming appliances till 2030 and explores policy options to accelerate adoption of more energy efficient appliances. India's rapid economic growth has enabled the growing middle class to buy household appliances in increasing numbers. The consequent rise in energy consumption and GHG emissions can be significantly reduced if consumers are motivated by awareness and options in the market to buy energy efficient appliances. India has introduced a star rating scheme for appliances, and even without incentives consumers purchase star-rated appliances. The stock of household appliances is projected using the data of a national sample survey of household consumption, observed sale of star-rated appliances and projected consumption distribution. Estimated savings in households' electricity consumption from just four appliances, ACs, refrigerators, TVs, and ceiling fans, for which data were available, range from 52 bKwh to 145 bkwh in 2030, reductions of 10–27%. The corresponding reduction in CO 2 emissions will be between 42 Mt and 116 Mt in 2030. With policies of finance and bulk procurement to reduce costs, emissions reduction can be 128 Mt in 2030, a reduction of 30%. - Highlights: • Estimates the stock of selected household appliances with 20 classes of rural and urban households in the years 2030 in India. • Assesses the economics of energy efficient appliances. • Estimates spread of selected energy efficient appliances. • Assesses savings in energy consumption and CO 2 emissions in four alternative scenarios. • Suggests policies to promote energy efficient appliances.

  13. Synthesise of Zn O nano wires by direct oxidation method

    International Nuclear Information System (INIS)

    Farbod, M.; Ahangarpour, A.

    2007-01-01

    Zn O is a semiconductor which has a direct and wide energy band which is about 3.37 eV at room temperature. It has various applications from UV lasers, sensitive sensors, solar cells to photo catalysis applications. Zn O has different nano structures such as nanoparticles, nano wires, nano rods, nano tubes and nano belts. The one dimensional Zn O nano structures such as nano wires are very important because of their applications in nano electronics and nano photonics so different methods have been proposed to synthesize them. In this work large scale of Zn O nano wires are produced by direct oxidation a Zn substrate (which was cleaned by chemical methods) in air or oxygen atmosphere at 400 d eg C . Nano wires were investigated by scanning electron microscopy and energy dispersive x-ray measurements. Their diameter is about 30-150 nanometer and their length is about several micrometer. This method which acts without any catalyst is a convenient method to synthesis semiconductor nano wires.

  14. Dynamic Appliances Scheduling in Collaborative MicroGrids System.

    Science.gov (United States)

    Bilil, Hasnae; Aniba, Ghassane; Gharavi, Hamid

    2017-05-01

    In this paper a new approach which is based on a collaborative system of MicroGrids (MG's), is proposed to enable household appliance scheduling. To achieve this, appliances are categorized into flexible and non-flexible Deferrable Loads (DL's), according to their electrical components. We propose a dynamic scheduling algorithm where users can systematically manage the operation of their electric appliances. The main challenge is to develop a flattening function calculus (reshaping) for both flexible and non-flexible DL's. In addition, implementation of the proposed algorithm would require dynamically analyzing two successive multi-objective optimization (MOO) problems. The first targets the activation schedule of non-flexible DL's and the second deals with the power profiles of flexible DL's. The MOO problems are resolved by using a fast and elitist multi-objective genetic algorithm (NSGA-II). Finally, in order to show the efficiency of the proposed approach, a case study of a collaborative system that consists of 40 MG's registered in the load curve for the flattening program has been developed. The results verify that the load curve can indeed become very flat by applying the proposed scheduling approach.

  15. Laboratory Testing of Demand-Response Enabled Household Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B.; Jin, X.; Earle, L.

    2013-10-01

    With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses.The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

  16. Laboratory Testing of Demand-Response Enabled Household Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Sparn, B. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Jin, X. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Earle, L. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-10-01

    With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses. The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

  17. Dynamic Appliances Scheduling in Collaborative MicroGrids System

    Science.gov (United States)

    Bilil, Hasnae; Aniba, Ghassane; Gharavi, Hamid

    2017-01-01

    In this paper a new approach which is based on a collaborative system of MicroGrids (MG’s), is proposed to enable household appliance scheduling. To achieve this, appliances are categorized into flexible and non-flexible Deferrable Loads (DL’s), according to their electrical components. We propose a dynamic scheduling algorithm where users can systematically manage the operation of their electric appliances. The main challenge is to develop a flattening function calculus (reshaping) for both flexible and non-flexible DL’s. In addition, implementation of the proposed algorithm would require dynamically analyzing two successive multi-objective optimization (MOO) problems. The first targets the activation schedule of non-flexible DL’s and the second deals with the power profiles of flexible DL’s. The MOO problems are resolved by using a fast and elitist multi-objective genetic algorithm (NSGA-II). Finally, in order to show the efficiency of the proposed approach, a case study of a collaborative system that consists of 40 MG’s registered in the load curve for the flattening program has been developed. The results verify that the load curve can indeed become very flat by applying the proposed scheduling approach. PMID:28824226

  18. Evaluation of safety management in an Appliances manufacturing company

    Directory of Open Access Journals (Sweden)

    F. Golbabaei

    2015-01-01

    Full Text Available Introduction: Prevention of accidents and work related diseases, are not allowed regardless of the safety of employees, customers, contractors and other persons. Assessment of individual safety management activities could reduce many losses. Present study aimed to evaluate the safety management of a household appliance manufacturing company.  .Material and Method: This study has done in a household appliance manufacturing company in Damavand city. Two questionnaires were firstly designed based on the weighted scores. The questionnaire 1 consisted of 4 indicators: Safety of machinery, Electrical safety, Risk assessment and Fire safety. Questionnaire 2 consisted of 11 sub indicators. Both questionnaires were completed by 30 HSE experts and supervisors. Reliability of questionnaires was based on cronbachs alpha coefficient. the safety status of each unit was determined and scored using information acquired by the questionnaires. Lastly, the safety of the entire company was determined.  .Result: Results showed that in safety management: the pressing and store house were in a good range of 66.66 and 60.12 points. Powder painting, enameling, laboratory were in a average range of 56.25, 55.92 and 54.15 points. Assembling and door storage were in a week range of 46.06 points.  .Conclusion: The findings showed that the safety status in the studied appliances company is in average range with 55.45 points. Therefore, it is recommended that the safety indicators should be improved for the betterment of the safety management in the company.

  19. Progress toward Producing Demand-Response-Ready Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstrom, Donald J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sastry, Chellury [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2009-12-01

    This report summarizes several historical and ongoing efforts to make small electrical demand-side devices like home appliances more responsive to the dynamic needs of electric power grids. Whereas the utility community often reserves the word demand response for infrequent 2 to 6 hour curtailments that reduce total electrical system peak load, other beneficial responses and ancillary services that may be provided by responsive electrical demand are of interest. Historically, demand responses from the demand side have been obtained by applying external, retrofitted, controlled switches to existing electrical demand. This report is directed instead toward those manufactured products, including appliances, that are able to provide demand responses as soon as they are purchased and that require few, or no, after-market modifications to make them responsive to needs of power grids. Efforts to be summarized include Open Automated Demand Response, the Association of Home Appliance Manufacturer standard CHA 1, a simple interface being developed by the U-SNAP Alliance, various emerging autonomous responses, and the recent PinBus interface that was developed at Pacific Northwest National Laboratory.

  20. Novel Wiring Technologies for Aerospace Applications

    Science.gov (United States)

    Gibson, Tracy L.; Parrish, Lewis M.

    2014-01-01

    Because wire failure in aerospace vehicles could be catastrophic, smart wiring capabilities have been critical for NASA. Through the years, researchers at Kennedy Space Center (KSC) have developed technologies, expertise, and research facilities to meet this need. In addition to aerospace applications, NASA has applied its knowledge of smart wiring, including self-healing materials, to serve the aviation industry. This webinar will discuss the development efforts of several wiring technologies at KSC and provide insight into both current and future research objectives.

  1. Clinical bending of nickel titanium wires

    OpenAIRE

    Stephen Chain; Priyank Seth; Namrata Rastogi; Kenneth Tan; Mayank Gupta; Richa Singh

    2015-01-01

    Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our invento...

  2. Towards Unconventional Applications of Wire Bonding

    OpenAIRE

    Schröder, Stephan

    2018-01-01

    This thesis presents novel heterogeneous integration approaches of wire materials to fabricated and package MEMS devices by exploring unconventional applications of wire bonding technology. Wire bonding, traditionally endemic in the realm of device packaging to establish electrical die-to-package interconnections, is an attractive back-end technology, offering promising features, such as high throughput, flexibility and placement accuracy. Exploiting the advantages of state-of-the-art wire bo...

  3. Different mechanical properties in Seldinger guide wires

    Directory of Open Access Journals (Sweden)

    Wolfram Schummer

    2015-01-01

    Full Text Available Background and Aims: Most central venous catheters are placed using Seldinger guide wires. EN ISO 11070 is the guideline for testing guide wire flexing performance and tensile strength, and we can safely assume that guide wires in use meet these requirements. Unfortunately, EN ISO 11070 guidelines do not reflect the clinical requirements and we continue to see mechanical failures and their associated complications. Material and Methods: This in vitro study was performed in an accredited laboratory. With regard to flexing, we: (1 Established the minimum flexing performance needed to meet clinical requirements, (2 developed flexing performance tests which mimic clinical requirement, and (3 evaluated the mechanical properties of various guide wires relative to these requirements. With regard to tensile strength, we used the testing method prescribed in ISO 11070, but did not end the test at 5 Newton (N. We continued until the guide wire was damaged, or we reached maximum tractive force. We then did a wire-to-wire comparison. We examined two basic wire constructions, monofil and core and coil. Results: Tensile strength: All wires tested, except one, met EN ISO 11070 requirements for 5 N tensile strength. The mean of the wire types tested ranged from 15.06 N to 257.76 N. Flexing performance: None of the wires kinked. The monofil had no evidence of bending. Two core/coil wires displayed minor bending (angle 1.5°. All other wires displayed bending angles between 22.5° and 43.0°. Conclusion: We recommend that: (1 Clinicians use guide wires with high-end mechanical properties, (2 EN ISO 11070 incorporate our flexing test into their testing method, raise the flexing requirement to kink-proof, (3 and raise the tensile strength requirement to a minimum of 30 N, and (3 all manufacturers and suppliers be required to display mechanical properties of all guide wire, and guide wire kits sold.

  4. Vocational Preparation Curriculum: Electrical Wiring.

    Science.gov (United States)

    Usoro, Hogan

    This document is a curriculum guide for instructors teaching vocational preparation for electrical wiring to special needs students. The purpose of the curriculum guide is to provide minimum skills for disadvantaged and handicapped students entering the mainstream; to supplement vocational skills of those students already in a regular training…

  5. Transparency in nanophotonic quantum wires

    International Nuclear Information System (INIS)

    Singh, Mahi R

    2009-01-01

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  6. Health care's 100 most wired.

    Science.gov (United States)

    Solovy, A; Serb, C

    1999-02-01

    They're wired all right, and America's 100 most techno-savvy hospitals and health systems share one more thing: a commitment to using technology to link with employees, patients, suppliers, and insurers. "We want to be a health care travel agency for our community," says one chief information officer. "And we see Internet technology as a key."

  7. Multi-anode wire straw tube tracker

    International Nuclear Information System (INIS)

    Oh, S.H.; Ebenstein, W.L.; Wang, C.W.

    2011-01-01

    We report on a test of a straw tube detector design having several anode (sense) wires inside a straw tube. The anode wires form a circle inside the tube and are read out independently. This design could solve several shortcomings of the traditional single wire straw tube design such as double hit capability and stereo configuration.

  8. On the preparation of superconducting wires

    International Nuclear Information System (INIS)

    Topare, R.J.; Chinchure, A.D.; Shah, S.S.; Hadole, G.B.

    1993-01-01

    The different methods of preparation of superconducting wires have been discussed. The powder-in-tube technique is followed for the preparation of YBCO and BISCCO superconducting wires. The results are discussed. The present status of the industries in preparing the superconducting wires having the maximum J c values is discussed. (author). 30 refs., 6 figs., 2 tabs

  9. Pre-wired systems prove their worth.

    Science.gov (United States)

    2012-03-01

    The 'new generation' of modular wiring systems from Apex Wiring Solutions have been specified for two of the world's foremost teaching hospitals - the Royal London and St Bartholomew's Hospital, as part of a pounds sterling 1 billion redevelopment project, to cut electrical installation times, reduce on-site waste, and provide a pre-wired, factory-tested, power and lighting system. HEJ reports.

  10. 75 FR 4584 - Wire Decking From China

    Science.gov (United States)

    2010-01-28

    ... COMMISSION Wire Decking From China AGENCY: United States International Trade Commission. ACTION: Scheduling... retarded, by reason of subsidized and less-than-fair-value imports from China of wire decking, provided for..., producers, or exporters in China of wire decking, and that such ] products are being sold in the United...

  11. Appliance Efficiency Standards and Price Discrimination

    Energy Technology Data Exchange (ETDEWEB)

    Spurlock, Cecily Anna [Univ. of California, Berkeley, CA (United States)

    2013-05-08

    I explore the effects of two simultaneous changes in minimum energy efficiency and ENERGY STAR standards for clothes washers. Adapting the Mussa and Rosen (1978) and Ronnen (1991) second-degree price discrimination model, I demonstrate that clothes washer prices and menus adjusted to the new standards in patterns consistent with a market in which firms had been price discriminating. In particular, I show evidence of discontinuous price drops at the time the standards were imposed, driven largely by mid-low efficiency segments of the market. The price discrimination model predicts this result. On the other hand, in a perfectly competition market, prices should increase for these market segments. Additionally, new models proliferated in the highest efficiency market segment following the standard changes. Finally, I show that firms appeared to use different adaptation strategies at the two instances of the standards changing.

  12. Association of tooth brushing behavior with oral hygiene index among students using fixed appliance

    Science.gov (United States)

    Ria, N.; Eyanoer, P.

    2018-03-01

    Uses of fixed appliance have become popular recently. The purpose of its use is to correct malposition of teeth in order to normalize the masticatory function and to eliminate the accumulation of food remain between the teeth. These will prevent the formation of caries and any periodontal tissue disease. Fixed appliance patients must routinely maintain their oral hygiene. This study was an analytical survey with cross-sectional design to know the relationship between behavior in tooth brushing of students using thefixed appliance and oral hygiene in Poltekkes Kemenkes Medan. The average of Oral Hygiene Index – Simplified (OHI-S) value of students using fixed appliance (2.68) was still above national target which is ≤2, and there was a relationship between behavior in tooth brushing of students using the fixed appliance and oral hygiene (poral hygiene and to prevent caries formation and periodontal disease patients using fixed appliances should maintain their dental health.

  13. Pacific Northwest GridWise™ Testbed Demonstration Projects; Part II. Grid Friendly™ Appliance Project

    Energy Technology Data Exchange (ETDEWEB)

    Hammerstrom, Donald J.; Brous, Jerry; Chassin, David P.; Horst, Gale R.; Kajfasz, Robert; Michie, Preston; Oliver, Terry V.; Carlon, Teresa A.; Eustis, Conrad; Jarvegren, Olof M.; Marek, W.; Munson, Ryan L.; Pratt, Robert G.

    2007-10-01

    Fifty residential electric water heaters and 150 new residential clothes dryers were modified to respond to signals received from underfrequency, load-shedding appliance controllers. Each controller monitored the power-grid voltage signal and requested that electrical load be shed by its appliance whenever electric power-grid frequency fell below 59.95 Hz. The controllers and their appliances were installed and monitored for more than a year at residential sites at three locations in Washington and Oregon. The controllers and their appliances responded reliably to each shallow underfrequency event—an average of one event per day—and shed their loads for the durations of these events. Appliance owners reported that the appliance responses were unnoticed and caused little or no inconvenience for the homes’ occupants.

  14. The HayWired Earthquake Scenario

    Science.gov (United States)

    Detweiler, Shane T.; Wein, Anne M.

    2017-04-24

    interconnectedness of infrastructure, society, and our economy. How would this earthquake scenario, striking close to Silicon Valley, impact our interconnected world in ways and at a scale we have not experienced in any previous domestic earthquake?The area of present-day Contra Costa, Alameda, and Santa Clara Counties contended with a magnitude-6.8 earthquake in 1868 on the Hayward Fault. Although sparsely populated then, about 30 people were killed and extensive property damage resulted. The question of what an earthquake like that would do today has been examined before and is now revisited in the HayWired scenario. Scientists have documented a series of prehistoric earthquakes on the Hayward Fault and are confident that the threat of a future earthquake, like that modeled in the HayWired scenario, is real and could happen at any time. The team assembled to build this scenario has brought innovative new approaches to examining the natural hazards, impacts, and consequences of such an event. Such an earthquake would also be accompanied by widespread liquefaction and landslides, which are treated in greater detail than ever before. The team also considers how the now-prototype ShakeAlert earthquake early warning system could provide useful public alerts and automatic actions.Scientific Investigations Report 2017–5013 and accompanying data releases are the products of an effort led by the USGS, but this body of work was created through the combined efforts of a large team including partners who have come together to form the HayWired Coalition (see chapter A). Use of the HayWired scenario has already begun. More than a full year of intensive partner engagement, beginning in April 2017, is being directed toward producing the most in-depth look ever at the impacts and consequences of a large earthquake on the Hayward Fault. With the HayWired scenario, our hope is to encourage and support the active ongoing engagement of the entire community of the San Francisco Bay region by

  15. The HayWired earthquake scenario

    Science.gov (United States)

    Detweiler, Shane T.; Wein, Anne M.

    2017-04-24

    interconnectedness of infrastructure, society, and our economy. How would this earthquake scenario, striking close to Silicon Valley, impact our interconnected world in ways and at a scale we have not experienced in any previous domestic earthquake?The area of present-day Contra Costa, Alameda, and Santa Clara Counties contended with a magnitude-6.8 earthquake in 1868 on the Hayward Fault. Although sparsely populated then, about 30 people were killed and extensive property damage resulted. The question of what an earthquake like that would do today has been examined before and is now revisited in the HayWired scenario. Scientists have documented a series of prehistoric earthquakes on the Hayward Fault and are confident that the threat of a future earthquake, like that modeled in the HayWired scenario, is real and could happen at any time. The team assembled to build this scenario has brought innovative new approaches to examining the natural hazards, impacts, and consequences of such an event. Such an earthquake would also be accompanied by widespread liquefaction and landslides, which are treated in greater detail than ever before. The team also considers how the now-prototype ShakeAlert earthquake early warning system could provide useful public alerts and automatic actions.Scientific Investigations Report 2017–5013 and accompanying data releases are the products of an effort led by the USGS, but this body of work was created through the combined efforts of a large team including partners who have come together to form the HayWired Coalition (see chapter A). Use of the HayWired scenario has already begun. More than a full year of intensive partner engagement, beginning in April 2017, is being directed toward producing the most in-depth look ever at the impacts and consequences of a large earthquake on the Hayward Fault. With the HayWired scenario, our hope is to encourage and support the active ongoing engagement of the entire community of the San Francisco Bay region by

  16. Wire chamber radiation detector with discharge control

    International Nuclear Information System (INIS)

    Perez-Mendez, V.; Mulera, T.A.

    1984-01-01

    A wire chamber radiation detector has spaced apart parallel electrodes and grids defining an ignition region in which charged particles or other ionizing radiations initiate brief localized avalanche discharges and defining an adjacent memory region in which sustained glow discharges are initiated by the primary discharges. Conductors of the grids at each side of the memory section extend in orthogonal directions enabling readout of the X-Y coordinates of locations at which charged particles were detected by sequentially transmitting pulses to the conductors of one grid while detecting transmissions of the pulses to the orthogonal conductors of the other grid through glow discharges. One of the grids bounding the memory region is defined by an array of conductive elements each of which is connected to the associated readout conductor through a separate resistance. The wire chamber avoids ambiguities and imprecisions in the readout of coordinates when large numbers of simultaneous or near simultaneous charged particles have been detected. Down time between detection periods and the generation of radio frequency noise are also reduced

  17. Sample of superconducting wiring from the LHC

    CERN Multimedia

    The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. Magnet coils are made of copper-clad niobium–titanium cables — each wire in the cable consists of 9’000 niobium–titanium filaments ten times finer than a hair. The cables carry up to 12’500 amps and must withstand enormous electromagnetic forces. At full field, the force on one metre of magnet is comparable to the weight of a jumbo jet. Coil winding requires great care to prevent movements as the field changes. Friction can create hot spots wh...

  18. Clinical bending of nickel titanium wires

    Directory of Open Access Journals (Sweden)

    Stephen Chain

    2015-01-01

    Full Text Available Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our inventory but also customized the wire according to the treatment.

  19. Emittance growth due to Tevatron flying wires

    Energy Technology Data Exchange (ETDEWEB)

    Syphers, M; Eddy, Nathan

    2004-06-01

    During Tevatron injection, Flying Wires have been used to measure the transverse beam size after each transfer from the Main Injector in order to deduce the transverse emittances of the proton and antiproton beams. This amounts to 36 + 9 = 45 flies of each of 3 wire systems, with an individual wire passing through each beam bunch twice during a single ''fly''. below they estimate the emittance growth induced by the interaction of the wires with the particles during these measurements. Changes of emittance from Flying Wire measurements conducted during three recent stores are compared with the estimations.

  20. Frog Appliance- An Innovative Treatment Option for the Replacement of Missing Teeth in An Epileptic Child

    Science.gov (United States)

    Goyal, Anita; Reddy, Hanumanth; Sajjnar, Arun B; Jain, Sonal

    2015-01-01

    Epilepsy is a chronic neurological disease which may result in various oro-facial injuries among which fracture of crown and avulsion of tooth are commonly reported. Challenges come in growing epileptic children where fixed prosthesis could not be delivered and it demands a fixed semi-permanent prosthesis that needs strength along with esthetics. The present paper reports an innovative appliance which has fulfilled fore mentioned criteria; with the appliance named-frog appliance. PMID:26155578

  1. Post-Retention Changes in Class II Correction With the Forsus (trademark) Appliance

    Science.gov (United States)

    2015-06-01

    ForsusTM appliance. Methods: 40 Class II patients (25 males , 15 females) consecutively treated with the ForsusTM appliance had cephalometric radiographs...was taken. Sample Population The 40 patients (25 male , 15 female) treated with the ForsusTM in conjunction with fixed appliances for a mean...range of values were caused by the experimental group 46 containing individuals who were treated early (i.e. before puberty ) and those who were

  2. The influence of bracket design on frictional losses in the bracket/arch wire system.

    Science.gov (United States)

    Schumacher, H A; Bourauel, C; Drescher, D

    1999-01-01

    In arch guided tooth movement, the essential role played by bracket configuration with respect to sliding friction has been recognized by the manufacturers, a fact which has had an increasing impact on the design and marketing of new bracket models in recent years. The aim of the present in-vitro study was to investigate the influence of different bracket designs on sliding mechanics. Five differently shaped stainless steel brackets (Discovery: Dentaurum, Damon SL: A-Company, Synergy: Rocky Mountain Orthodontics, Viazis bracket and Omni Arch appliance: GAC) were compared in the 0.022"-slot system. The Orthodontic Measurement and Simulation System (OMSS) was used to quantify the difference between applied force (NiTi coil spring, 1.0 N) and orthodontically effective force and to determine leveling losses occurring during the sliding process in arch guided tooth movement. Simulated canine retraction was performed using continuous arch wires with the dimensions 0.019" x 0.025" (Standard Steel, Unitek) and 0.020" x 0.020" (Ideal Gold, GAC). Comparison of the brackets revealed friction-induced losses ranging from 20 to 70%, with clear-cut advantages resulting from the newly developed bracket types. However, an increased tendency towards leveling losses in terms of distal rotation (maximum 15 degrees) or buccal root torque (maximum 20 degrees) was recorded, especially with those brackets giving the arch wire increased mobility due to their shaping or lack of ligature wire.

  3. Mechanical properties of orthodontic wires covered with a polyether ether ketone tube.

    Science.gov (United States)

    Shirakawa, Nobukazu; Iwata, Toshio; Miyake, Shinjiro; Otuka, Takero; Koizumi, So; Kawata, Toshitugu

    2018-03-21

    To evaluate the esthetics and frictional force of an orthodontic wire passed through a newly designed tube made of a polyether ether ketone (PEEK) resin. Two types of standard PEEK tubes were prepared at 0.5 × 0.6ф and 0.8 × 0.9ф, and different archwires were passed through the tubes. Color values were determined according to brightness and hues. Friction was assessed with different bracket-wire combinations, and surface roughness was determined by stereomicroscopy before and after the application of friction. The PEEK tube showed a color difference that was almost identical to that of coated wires conventionally used in clinical practice, indicating a sufficient esthetic property. The result of the friction test showed that the frictional force was greatly reduced by passing the archwire through the PEEK tube in almost all of the archwires tested. Use of the new PEEK tube demonstrated a good combination of esthetic and functional properties for use in orthodontic appliances.

  4. Early treatment of Class III malocclusion by RME and modified Tandem appliance

    Directory of Open Access Journals (Sweden)

    Juhi Ansar

    2015-01-01

    Full Text Available Patients with a skeletal Class III malocclusion and maxillary deficiency can be treated successfully using a combined protraction facemask and alternate rapid maxillary expansions and contractions (Alt-RAMEC. However, due to poor patient compliance during facemask therapy there has been growing interest in intraoral appliances for correcting Class III malocclusion. The tandem traction bow appliance (TTBA is an intraoral appliance which has been used successfully for the treatment of growing Class III patients. This case report describes the management of a 10-year-old boy with a Class III malocclusion and maxillary deficiency treated with modified TTBA appliance.

  5. When do energy-efficient appliances generate energy savings? Some evidence from Canada

    International Nuclear Information System (INIS)

    Young, Denise

    2008-01-01

    Improvements in the energy efficiency of household appliances have the potential to decrease residential energy use, but these reductions accrue gradually over time as newer appliances replace older models. SHEU-2003 data are used to examine appliance replacement patterns in Canada for refrigerators, freezers, dishwashers, clothes washers and clothes dryers. The data indicate that the ages at which appliances are replaced tend to be lowest for dishwashers and highest for freezers, with over 40% of freezers in use for more than 20 years before being retired. The life spans of Canadian appliances are compared to the underlying assumptions regarding appliance lifetimes used in models of residential energy demand. We find that Canadian appliance retirement patterns differ from those assumed in the previous literature. Socioeconomic factors related to appliance replacement are also examined. We find that replacement patterns can be sensitive to household characteristics such as income, providing evidence that there may be scope for targeted policies aimed at inducing earlier replacements of older household appliances with new energy-efficient models

  6. The impact of personality on adult patients' adjustability to orthodontic appliances.

    Science.gov (United States)

    Cooper-Kazaz, Rena; Ivgi, Inbal; Canetti, Laura; Bachar, Eytan; Tsur, Boaz; Chaushu, Stella; Shalish, Miriam

    2013-01-01

    To evaluate the impact of psychological traits on patients' choice of orthodontic appliances and their adjustability to orthodontic treatment. The sample consisted of 68 adult patients divided into three groups (28 buccal, 19 lingual, and 21 clear aligners). Prior to treatment participants filled out the Brief Symptom Inventory to assess symptoms of mental distress and the Narcissistic Vulnerability Scale to assess narcissistic personality traits. During the first week after appliance delivery and on day 14, patients completed a Health-Related Quality of Life questionnaire to assess their perception of pain and four areas of dysfunction. The correlation between personality traits and patients' reaction to treatment was evaluated. Somatization was the only trait that affected the choice of lingual and clear aligner appliance. Reduced self-esteem regulation was associated with increased pain in all patients, while exploitation was associated with pain in lingual patients. Narcissistic vulnerability slightly influenced patients' adaptability to orthodontic appliances. Although adjustability to lingual appliances was the most difficult, only two parameters were affected by personality features. In the buccal group, adjustability was affected by numerous parameters. Adaptation to the clear aligner appliance was relatively uneventful and least affected by psychological features. Anxious individuals tend to prefer lingual and clear aligner appliances. The selection of lingual and clear aligner appliances governs the patient's response and recovery process, leaving little room for the effect of psychological features. On the other hand, the buccal appliance allows for greater impact of personality traits on adjustability.

  7. Assessing consumer benefits of selected gas appliance technology center tasks. Topical report, April-December 1992

    International Nuclear Information System (INIS)

    Smith, T.R.; Bournakis, A.D.; Worek, W.M.; Kalensky, D.C.; Dombrowski, L.P.

    1992-12-01

    The Gas Appliance Technology Center (GATC) was created in 1983 to assist the gas industry in bringing about a new generation of reasonably priced, advanced gas appliances. The objective of the report is to evaluate consumer benefits of sixteen selected GATC tasks for the time period between 1983 and 1990. Tasks were selected for review based upon their degree of industry impact and how well they represented activities in the four targeted research areas of Space Conditioning, Commercial Appliances, Residential Appliances, and Codes and Standards

  8. Polyurethane spray coating of aluminum wire bonds to prevent corrosion and suppress resonant oscillations

    CERN Document Server

    INSPIRE-00092738; Kurth, Matthew; Boyd, Rusty

    2016-01-01

    Unencapsulated aluminum wedge wire bonds are common in particle physics pixel and strip detectors. Industry-favored bulk encapsulation is eschewed due to the range of operating temperatures and radiation. Wire bond failures are a persistent source of tracking-detector failure. Unencapsulated bonds are vulnerable to condensation-induced corrosion, particularly when halides are present. Oscillations from periodic Lorentz forces are documented as another source of wire bond failure. Spray application of polyurethane coatings, performance of polyurethane-coated wire bonds after climate chamber exposure, and resonant properties of polyurethane-coated wire bonds and their resistance to periodic Lorentz forces are under study for use in a future High Luminosity Large Hadron Collider detector such as the ATLAS Inner Tracker upgrade.

  9. Reduction of peak energy demand based on smart appliances energy consumption adjustment

    Science.gov (United States)

    Powroźnik, P.; Szulim, R.

    2017-08-01

    In the paper the concept of elastic model of energy management for smart grid and micro smart grid is presented. For the proposed model a method for reducing peak demand in micro smart grid has been defined. The idea of peak demand reduction in elastic model of energy management is to introduce a balance between demand and supply of current power for the given Micro Smart Grid in the given moment. The results of the simulations studies were presented. They were carried out on real household data available on UCI Machine Learning Repository. The results may have practical application in the smart grid networks, where there is a need for smart appliances energy consumption adjustment. The article presents a proposal to implement the elastic model of energy management as the cloud computing solution. This approach of peak demand reduction might have application particularly in a large smart grid.

  10. Vibrating wire for beam profile scanning

    Directory of Open Access Journals (Sweden)

    S. G. Arutunian

    1999-12-01

    Full Text Available A method that measures the transverse profile (emittance of the bunch by detecting radiation arising at the scattering of the bunch on scanning wire is widely used. In this work information about bunch scattering is obtained by measuring the oscillation frequency of the tightened scanning wire. In such a way, the system of radiation (or secondary particles extraction and measurement can be removed. The entire unit consists of a compact fork with tightened wire and a scanning system. Normal oscillation frequency of a wire depends on wire tension, its geometric parameters, and, in a second approximation, its elastic characteristics. Normal oscillations are generated by interaction of an alternating current through the wire with magnetic field of a permanent magnet. In this case, it is suggested that the magnetic field of the accelerator (field of dipole magnets or quadrupole magnets be used for excitation of oscillations. The dependence of oscillation frequency on beam scattering is determined by several factors, including changes of wire tension caused by transverse force of the beam and influence of beam self-field. Preliminary calculations show that the influence of wire heating will dominate. We have studied strain gauges on the basis of vibrating wire from various materials (tungsten, beryl bronze, and niobium zirconium alloys. A scheme of normal oscillation generation by alternating current in autogeneration circuit with automatic frequency adjustment was selected. A special method of wire fixation and elimination of transverse degrees of freedom allows us to achieve relative stability better than 10^{-5} during several days at a relative resolution of 10^{-6}. Experimental results and estimates of wire heating of existing scanners show that the wire heats up to a few hundred grades, which is enough for measurements. The usage of wire of micrometer thickness diminishes the problem of wire thermalization speed during the scanning of the bunch.

  11. Modifications in straight wire treatment.

    Science.gov (United States)

    Cardona, Alvin

    2010-01-01

    Orthodontic treatments have been modified with each new generation of clinicians. Today the emphasis is on facial esthetics and healthy temporomandibular joints. With orthopedic treatment, we can develop dental arches to get the necessary space to align the teeth and we can reach adequate function and esthetics, all within relatively good stability. By combining two-phase treatment with low friction fixed orthodontics and super elastic wires we produce light but continuous forces and we can provide better treatment than before. These types of forces cause physiological and functional orthopedic orthodontic reactions. The purpose of this article is to demonstrate our fixed orthopedic and orthodontic approach called "Modified Straight Wire" or "Physiologic Arch Technique." This technique is very successful with our patients because it can exert slow and continuous forces with minimal patient cooperation.

  12. Sintered wire cesium dispenser photocathode

    Science.gov (United States)

    Montgomery, Eric J; Ives, R. Lawrence; Falce, Louis R

    2014-03-04

    A photoelectric cathode has a work function lowering material such as cesium placed into an enclosure which couples a thermal energy from a heater to the work function lowering material. The enclosure directs the work function lowering material in vapor form through a low diffusion layer, through a free space layer, and through a uniform porosity layer, one side of which also forms a photoelectric cathode surface. The low diffusion layer may be formed from sintered powdered metal, such as tungsten, and the uniform porosity layer may be formed from wires which are sintered together to form pores between the wires which are continuous from the a back surface to a front surface which is also the photoelectric surface.

  13. Effects of the pendulum appliance, cervical headgear, and 2 premolar extractions followed by fixed appliances in patients with Class II malocclusion.

    Science.gov (United States)

    de Almeida-Pedrin, Renata Rodrigues; Henriques, José Fernando Castanha; de Almeida, Renato Rodrigues; de Almeida, Marcio Rodrigues; McNamara, James A

    2009-12-01

    In this retrospective study, we compared the cephalometric effects, the dental-arch changes, and the efficiency of Class II treatment with the pendulum appliance, cervical headgear, or extraction of 2 maxillary premolars, all associated with fixed appliance therapy. The sample of 82 patients with Class II malocclusion was divided into 3 groups: group 1 patients (n = 22; treatment time, 3.8 years) were treated with the pendulum appliance and fixed orthodontic appliances. Group 2 patients (n = 30; treatment time, 3.2 years) were treated with cervical headgear followed by fixed appliances; group 3 patients (n = 30; treatment time, 2.1 years) were treated with 2 maxillary premolar extractions and fixed appliances. The average starting ages of the groups ranged from 13.2 to 13.8 years. Data were obtained from serial cephalometric measurements and dental casts. The dental casts were analyzed with the treatment priority index. The treatment efficiency index was also used. The 3 treatment protocols produced similar cephalometric effects, especially skeletally. Comparisons among the 2 distalizing appliances (pendulum and cervical headgear) and extraction of 2 maxillary premolars for Class II treatment showed changes primarily in the maxillary dentoalveolar component and dental relationships. The facial profile was similar after treatment, except for slightly more retrusion of the upper lip in the extraction patients. The treatment priority index demonstrated that occlusal outcomes also were similar among the groups. The treatment efficiency index had higher values for the extraction group. The effects of treatment with the pendulum appliance or cervical headgear and extraction of 2 maxillary premolars associated with fixed appliances were similar from both occlusal and cephalometric standpoints. Class II treatment with extraction of maxillary teeth was more efficient because of the shorter treatment time. Differences in maxillary incisor retraction should be noted, but

  14. Reduction of Gas Bubbles and Improved Critical Current Density in Bi-2212 Round Wire by Swaging

    CERN Document Server

    Jiang, J; Huang, Y; Hong, S; Parrell, J; Scheuerlein, C; Di Michiel, M; Ghosh, A; Trociewitz, U; Hellstrom, E; Larbalestier, D

    2013-01-01

    Bi-2212 round wire is made by the powder-in-tube technique. An unavoidable property of powder-in-tube conductors is that there is about 30% void space in the as-drawn wire. We have recently shown that the gas present in the as-drawn Bi-2212 wire agglomerates into large bubbles and that they are presently the most deleterious current limiting mechanism. By densifying short 2212 wires before reaction through cold isostatic pressing (CIPping), the void space was almost removed and the gas bubble density was reduced significantly, resulting in a doubled engineering critical current density (JE) of 810 A/mm2 at 5 T, 4.2 K. Here we report on densifying Bi-2212 wire by swaging, which increased JE (4.2 K, 5 T) from 486 A/mm2 for as-drawn wire to 808 A/mm2 for swaged wire. This result further confirms that enhancing the filament packing density is of great importance for making major JE improvement in this round-wire magnet conductor.

  15. Simulating the Wire Compensation of LHC Long-Range Beam-beam Effects.

    CERN Document Server

    Rijoff, T

    2012-01-01

    The performance of the Large Hadron Collider (LHC) and its minimum crossing angle are limited by long-range beam-beam collisions. Wire compensators can mitigate part of the long-range effects. We perform simulations to explore the efficiency of the compensation at possible wire locations by examining the tune footprint and the dynamic aperture. Starting from the weak-strong simulation code BBTrack we developed a new Lyapunov calculation tool, which seems to better diagnose regular or chaotic particle behavior. We also developed faster ways to execute the simulation and the post-processing. These modifications have allowed us to study different wire positions (longitudinal and transverse), varying wire currents, several wire shapes, and a range of beam-beam crossing angles, in view of a prototype wire installation in the LHC foreseen for 2014/15. Our simulations demonstrate that the wire can provide a good compensation, including for reduced crossing angle. Among the benefits of an LHC wire compensator are a b...

  16. Standby consumption of household appliances; Standby-Verbrauch von Haushaltgeraeten

    Energy Technology Data Exchange (ETDEWEB)

    Nipkow, J.; Bush, E.

    2003-07-01

    While electricity consumption of household appliances is well documented for conventional operation cycles, there are still many gaps in our knowledge regarding consumption in the standby status. The aim of this project was to obtain new findings by carrying out market surveys, measurements and evaluations. The total standby losses for household appliances in Switzerland amount to approximately 400 GWh, and the associated electricity costs are about 80 million Swiss francs. The greatest fraction - approximately 80 percent - is traceable to heating requirements for coffee machines. In some appliance categories the share of standby losses compared to overall electricity consumption is extremely high. This figure for coffee machines in offices is 84 percent, for coffee machines in private households it is 60 percent, and for induction cooker tops it is 48 percent. The main technical requirements for enhancing the energy efficiency of coffee machines are an automatic switch-off function and improved insulation of boilers. According to the latest manufacturers' specifications of induction cooker tops, it is apparently possible to significantly reduce the surprisingly high losses associated with control devices. Generally speaking, the efficiency of power supply units could still be improved. It is now possible to reduce consumption levels from the previously standard level of about 4 W to less than 0.5 W. Since it appears that relatively simple measures may significantly increase the efficiency, it is recommended that action be taken. Here, it is essential to work out detailed guidelines and define testing standards for declaring standby losses. The proposal put forward here for an energy declaration for coffee machines is intended to help test centres, EU authorities and manufacturers to carry out uniform measurements and evaluations. Given the high power consumption of coffee machines, their significant efficiency enhancement potential and the availability of

  17. APPLIANCE OF COMPETITORS TECHNIQUES IN LEADING THE SKIES IN TURNING

    Directory of Open Access Journals (Sweden)

    Rašid Hadžić

    2009-11-01

    Full Text Available Competitors techniques in skiing characterize driving on edges, without gliding in certain fazes of turning. Today that characteristic is more and more present in all di- scipline, (downhill, super G, giant slalom and slalom so we can talk about appliance of basic technique of leading skies on all disciplines, with differences in position of skies in amplitude of moving and frequencies of changes of edges. From that point of view we distinct three typical shape of moving in turning, which have mutual distinction in influence on ski loading, and that has influence on tur- ning line and acceleration or checking in certain fazes of turning.

  18. The Next Generation of Appliances: Visions for Sustainability

    DEFF Research Database (Denmark)

    Nørgaard, Jørgen; Guldbrandsen, Tom

    1998-01-01

    to consume no more than 50 kWh per year, without using any risky synthetic gasses. Washing appliances will use no electricity for heating, which will bring annual electricity consumption below 50 kWh for a washing machine. For electronic equipment, the efficiency gain known from battery operated version...... should be applied to units on the main supply, bringing the electricity consumption for a computer used 2 hours per day down to 5 kWh per year, for instance. With careful behaviour, annual electricity consumption for a household can easily be brought down below 250 kWh per capita, compared to 1000-2000 kWh...

  19. Simplified feeding appliance for an infant with cleft palate

    Directory of Open Access Journals (Sweden)

    Shaila Masih

    2014-01-01

    Full Text Available A child born with cleft palate may experience difficulties while feeding. Early surgical treatment may need to be postponed until certain age and weight gain of the infant. The case presented here is of a 1-month-old neonate born with cleft palate, assisted with a new feeding appliance made with ethylene vinyl acetate using pressure molding technique to aid in proper feeding. The patient′s weight and health significantly improved after the insertion of obturator. The advantages of this material included being lightweight, moldability, good palatal fit and decreased soft tissue injury.

  20. Mechanical appliances, mechanical movements and novelties of construction

    CERN Document Server

    Hiscox, Gardner D

    2008-01-01

    From the devices that power ships and trains to the workings of clocks, typewriters, and guns, this engrossing visual narrative profiles the specific and unique properties of hundreds of mechanical devices. Nearly 1,000 detailed illustrations depict steam-powered appliances, spring-powered devices, hydraulic equipment, and other machines, many of which remain in common use today. Each apparatus features a detailed line drawing and an informative explanation of its workings and uses. A final chapter chronicles 400 years of impassioned but futile searching for a perpetual motion machine.The comp

  1. A comparison between indirect and objective wear-time assessment of removable orthodontic appliances.

    Science.gov (United States)

    Schott, Timm C; Meyer-Gutknecht, Hannes; Mayer, Nicolai; Weber, Joachim; Weimer, Katja

    2017-04-01

    Patients do not always adhere to the wear times prescribed for removable orthodontic appliances. We evaluated the validity and usability of indirect wear-time assessment methods by comparing wear-time estimates with microelectronically measured wear times in patients with removable orthodontic appliances. Wear times of 33 expansion plates, 34 functional appliances, and 42 retention plates of patients aged 6-20 years (12.3±2.9 years, 50.5% female) were indirectly determined by practitioners using a questionnaire assessing five parameters on a 5-point Likert scale: appliance handling, appliance appearance, bite shift, tooth movement, and appliance fit. The perceived difficulty in assessing each parameter was rated. Actual wear times were evaluated with microelectronic sensors in the appliances. Regression analyses revealed that practitioners' decisions about wear times varied depending on the type of appliance and criteria used, with only one standard criterion best predicting estimated wear time for each appliance. Different standard criteria were better predictors of measured wear time: 22.3% of wear-time variability was explained by expansion plate appearance, 31.2% by functional appliance handling, and 18.8% by retainer fitting. However, practitioners rated the difficulty of assessment in most cases as 'easy'. The study was not double blinded for technical reasons, and practitioners may have considered the evaluation criteria more carefully than in normal daily practice. Practitioners' decisions about wear times based on standard criteria strongly vary depending on the type of appliance and criteria used. © The Author 2016. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  2. A Vibrating Wire System For Quadrupole Fiducialization

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Zachary

    2010-12-13

    A vibrating wire system is being developed to fiducialize the quadrupoles between undulator segments in the LCLS. This note provides a detailed analysis of the system. The LCLS will have quadrupoles between the undulator segments to keep the electron beam focused. If the quadrupoles are not centered on the beam axis, the beam will receive transverse kicks, causing it to deviate from the undulator axis. Beam based alignment will be used to move the quadrupoles onto a straight line, but an initial, conventional alignment must place the quadrupole centers on a straight line to 100 {micro}m. In the fiducialization step of the initial alignment, the position of the center of the quadrupole is measured relative to tooling balls on the outside of the quadrupole. The alignment crews then use the tooling balls to place the magnet in the tunnel. The required error on the location of the quadrupole center relative to the tooling balls must be less than 25 {micro}m. In this note, we analyze a system under construction for the quadrupole fiducialization. The system uses the vibrating wire technique to position a wire onto the quadrupole magnetic axis. The wire position is then related to tooling balls using wire position detectors. The tooling balls on the wire position detectors are finally related to tooling balls on the quadrupole to perform the fiducialization. The total 25 {micro}m fiducialization error must be divided between these three steps. The wire must be positioned onto the quadrupole magnetic axis to within 10 {micro}m, the wire position must be measured relative to tooling balls on the wire position detectors to within 15 {micro}m, and tooling balls on the wire position detectors must be related to tooling balls on the quadrupole to within 10 {micro}m. The techniques used in these three steps will be discussed. The note begins by discussing various quadrupole fiducialization techniques used in the past and discusses why the vibrating wire technique is our method

  3. A Novel Two-Wire Fast Readout Approach for Suppressing Cable Crosstalk in a Tactile Resistive Sensor Array

    Directory of Open Access Journals (Sweden)

    Jianfeng Wu

    2016-05-01

    Full Text Available For suppressing the crosstalk problem due to wire resistances and contacted resistances of the long flexible cables in tactile sensing systems, we present a novel two-wire fast readout approach for the two-dimensional resistive sensor array in shared row-column fashion. In the approach, two wires are used for every driving electrode and every sampling electrode in the resistive sensor array. The approach with a high readout rate, though it requires a large number of wires and many sampling channels, solves the cable crosstalk problem. We also verified the approach’s performance with Multisim simulations and actual experiments.

  4. A Novel Two-Wire Fast Readout Approach for Suppressing Cable Crosstalk in a Tactile Resistive Sensor Array.

    Science.gov (United States)

    Wu, Jianfeng; Wang, Yu; Li, Jianqing; Song, Aiguo

    2016-05-18

    For suppressing the crosstalk problem due to wire resistances and contacted resistances of the long flexible cables in tactile sensing systems, we present a novel two-wire fast readout approach for the two-dimensional resistive sensor array in shared row-column fashion. In the approach, two wires are used for every driving electrode and every sampling electrode in the resistive sensor array. The approach with a high readout rate, though it requires a large number of wires and many sampling channels, solves the cable crosstalk problem. We also verified the approach's performance with Multisim simulations and actual experiments.

  5. Created in Close Interaction with the Industry: The Smart Appliances REFerence (SAREF) Ontology

    NARCIS (Netherlands)

    Daniele, L.M.; Hartog, F.T.H. den; Roes, J.B.M.

    2015-01-01

    Around two thirds of the energy consumed by buildings can be traced back to the residential sectors and thus household appliances. Today, most appliances are highly intelligent and networked devices, in principle being able to form complete energy consuming, producing, and managing systems. Reducing

  6. What to Do If Your Appliances Are Wet After a Disaster

    Centers for Disease Control (CDC) Podcasts

    2006-08-10

    If your home was flooded, look for signs that your appliances have gotten wet. Throw away wet or flooded appliances to protect from shock and fire.  Created: 8/10/2006 by Emergency Communications System.   Date Released: 7/30/2008.

  7. Regulating electricity demand peaks for home appliances using reversible fair scheduling

    DEFF Research Database (Denmark)

    Kardaras, Georgios; Rossello Busquet, Ana; Iversen, Villy Bæk

    2010-01-01

    This paper describes a novel methodology for regulating electricity demand peaks for home appliances. To achieve this objective, we will make use of the reversible fair scheduling algorithm originally developed for telecommunication networks. The main concept behind this approach is the aggregati....... Moreover, users will be granted lower electricity bill rates for accepting prolonging the operation of some of their home appliances....

  8. 46 CFR 160.031-4 - Equipment for shoulder gun type line-throwing appliance.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Equipment for shoulder gun type line-throwing appliance... Appliance, Shoulder Gun Type (and Equipment) § 160.031-4 Equipment for shoulder gun type line-throwing... the gun. The line canister shall be secured by clamps or brackets below the barrel of the gun. (c) One...

  9. Boundedly rational consumers, energy and investment literacy, and the display of information on household appliances

    NARCIS (Netherlands)

    Blasch, J.E.; Filippini, Massimo; Kumar, Nilkanth

    2017-01-01

    It is an ongoing debate how to increase the adoption of energy-efficient light bulbs and household appliances in the presence of the so-called ‘energy efficiency gap’. One measure to support consumers’ decision-making towards the purchase of more efficient appliances is the display of energy-related

  10. Open-bite treatment utilizing clear removable appliances with intermaxillary and intramaxillary elastics.

    Science.gov (United States)

    Park, Jae Hyun; Kim, Tae Weon

    2009-01-01

    Clear removable appliances with elastics can be effective and efficient in extruding maxillary teeth during aligner treatment or following a relapse of an open bite. Some patients with open bites refuse to wear conventional fixed appliances. In these individuals, clear aligners with elastics could be a valuable alternative. © 2009 Quintessence Publishing Co, Inc. All Rights Reserved

  11. A Study on Efficient Energy Use for Household Appliances in Malawi ...

    African Journals Online (AJOL)

    The energy consumption of various household appliances has been measured over a period of one month in Zomba using a Landis +Gyr power meter. It was observed that the electrical-cooking stove, water heater, dry iron, and incandescent bulbs were the most electrical power-consuming appliances. It has also been ...

  12. How do household characteristics affect appliance usage? Application of conditional demand analysis to Japanese household data

    International Nuclear Information System (INIS)

    Matsumoto, Shigeru

    2016-01-01

    Although both appliance ownership and usage patterns determine residential electricity consumption, it is less known how households actually use their appliances. In this study, we conduct conditional demand analyses to break down total household electricity consumption into a set of demand functions for electricity usage, across 12 appliance categories. We then examine how the socioeconomic characteristics of the households explain their appliance usage. Analysis of micro-level data from the Nation Survey of Family and Expenditure in Japan reveals that the family and income structure of households affect appliance usage. Specifically, we find that the presence of teenagers increases both air conditioner and dishwasher use, labor income and nonlabor income affect microwave usage in different ways, air conditioner usage decreases as the wife's income increases, and microwave usage decreases as the husband's income increases. Furthermore, we find that households use more electricity with new personal computers than old ones; this implies that the replacement of old personal computers increases electricity consumption. - Highlights: •We conduct conditional demand analyses to study household appliance usage. •Micro-level data from the National Survey of Family and Expenditure in Japan are analyzed. •We show how household characteristics determine appliance usage. •High-income households use specific appliances less intensively than low-income households. •The replacement of old TVs and PCs lead to greater electricity consumption.

  13. 49 CFR 236.312 - Movable bridge, interlocking of signal appliances with bridge devices.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Movable bridge, interlocking of signal appliances with bridge devices. 236.312 Section 236.312 Transportation Other Regulations Relating to... SYSTEMS, DEVICES, AND APPLIANCES Interlocking Standards § 236.312 Movable bridge, interlocking of signal...

  14. Implant-retained oral appliances : a novel treatment for edentulous patients with obstructive sleep apnea-hypopnea syndrome

    NARCIS (Netherlands)

    Hoekema, Aarnoud; de Vries, Frist; Heydenrijk, Kees; Stegenga, Boudewijn

    Objectives: Mandibular repositioning appliances (MRAs) are a viable treatment alternative in patients with obstructive sleep apnea-hypopnea syndrome (OSAHS). Because these appliances require retention in the patient's dentition, edentelous patients generally do not qualify for this treatment. This

  15. Treatment Effects of Occipitomental Anchorage Appliance of Maxillary Protraction Combined with Chincup Traction in Children with Class III Malocclusion

    Directory of Open Access Journals (Sweden)

    Hsiang-Chien Lin

    2007-05-01

    Conclusion: Our results suggest that the OMA orthopedic appliance can correct the mesial jaw relationship and negative incisal overjet. This appliance is effective for correcting skeletal Class III malocclusion with both midface deficiency and Mn prognathism in growing children.

  16. Electro-mechanics of drift tube wires

    International Nuclear Information System (INIS)

    Milburn, R.H.

    1997-01-01

    The position and stability of the sense wires in very long drift tubes are affected by both gravitational and electrostatic forces, as well as by the wire tension. For a tube to be used as an element of a high-resolution detector all these forces and their effects must be understood in appropriately precise detail. In addition, the quality control procedures applied during manufacture and detector installation must be adequate to ensure that the internal wire positions remain within tolerances. It may be instructive to practitioners to review the simple theory of a taut wire in the presence of anisotropic gravitational and electrostatic fields to illustrate the conditions for stability, the equilibrium wire displacement from straightness, and the effect of the fields on the mechanical vibration frequencies. These last may be used to monitor the wire configuration externally. A number of practical formulae result and these are applied to illustrative examples. (orig.)

  17. Electromagnetic Behaviour of Metallic Wire Structures

    CERN Document Server

    Chui, S T

    2013-01-01

    Despite the recent development and interest in the photonics of metallic wire structures, the relatively simple concepts and physics often remain obscured or poorly explained to those who do not specialize in the field. Electromagnetic Behaviour of Metallic Wire Structures provides a clear and coherent guide to understanding these phenomena without excessive numerical calculations.   Including both background material and detailed derivations of the various different formulae applied, Electromagnetic Behaviour of Metallic Wire Structures describes how to extend basic circuit theory relating to voltages, currents, and resistances of metallic wire networks to include situations where the currents are no longer spatially uniform along the wire. This lays a foundation for a deeper understanding of the many new phenomena observed in meta-electromagnetic materials.   Examples of applications are included to support this new approach making Electromagnetic Behaviour of Metallic Wire Structures a comprehensive and ...

  18. Phosphorus in antique iron music wire.

    Science.gov (United States)

    Goodway, M

    1987-05-22

    Harpsichords and other wire-strung musical instruments were made with longer strings about the beginning of the 17th century. This change required stronger music wire. Although these changes coincided with the introduction of the first mass-produced steel (iron alloyed with carbon), carbon was not found in samples of antique iron harpsichord wire. The wire contained an amount of phosphorus sufficient to have impeded its conversion to steel, and may have been drawn from iron rejected for this purpose. The method used to select pig iron for wire drawing ensured the highest possible phosphorus content at a time when its presence in iron was unsuspected. Phosphorus as an alloying element has had the reputation for making steel brittle when worked cold. Nevertheless, in replicating the antique wire, it was found that lowcarbon iron that contained 0.16 percent phosphorus was easily drawn to appropriate gauges and strengths for restringing antique harpsichords.

  19. Investigation of Overvoltage Phenomena due to Lightning Surge in Low Voltage Wiring

    Science.gov (United States)

    Tan, Akiyoshi; Koga, Soichi; Vasa, Nilesh J.; Yokoyama, Shigeru; Hosokawa, Takeshi; Sawabe, Kimihide; Yoshioka, Tetsuo; Soeda, Masahiro

    In order to understand overvoltage phenomena due to the lightning surge in a low voltage wiring on a scale model of a structure, the load circuit of electrical appliances at the end of cable with circuit elements, such as resistors, capacitors and inductors, was simulated and the response at the end of cable was studied. Furthermore experimental results were compared with those of the digital simulation using EMTP (Electro-Magnetic Transients Program). The variation in the voltage waveform generated at the end of cable according to the state of the load of an electrical equipment was confirmed based on experiments and simulations. However, when a varistor (Surge Protective Device) was inserted at the end of cable, the voltage amplitude was clamped by the varistor irrespective of the load circuit.

  20. Quench detection method for 2G HTS wire

    International Nuclear Information System (INIS)

    Marchevsky, M; Xie, Y-Y; Selvamanickam, V

    2010-01-01

    2G HTS conductors are increasingly used in various commercial applications and their thermal and electrical stability is an important reliability factor. Detection and prevention of quenches in 2G wire-based cables and solenoids has proven to be a difficult engineering task. This is largely due to a very slow normal zone propagation in coated conductors that leads to formation of localized hotspots while the rest of the conductor remains in the superconducting state. We propose an original method of quench and hotspot detection for 2G wires and coils that is based upon local magnetic sensing and takes advantage of 2G wire planar geometry. We demonstrate our technique experimentally and show that its sensitivity is superior to the known voltage detection scheme. A unique feature of the method is its capability to remotely detect instant degradation of the wire critical current even before a normal zone is developed within the conductor. Various modifications of the method applicable to practical device configurations are discussed.

  1. Quench detection method for 2G HTS wire

    Energy Technology Data Exchange (ETDEWEB)

    Marchevsky, M; Xie, Y-Y; Selvamanickam, V, E-mail: maxmarche@gmail.co, E-mail: yxie@superpower-inc.co [SuperPower, Inc., 450 Duane Avenue, Schenectady, NY 12304 (United States)

    2010-03-15

    2G HTS conductors are increasingly used in various commercial applications and their thermal and electrical stability is an important reliability factor. Detection and prevention of quenches in 2G wire-based cables and solenoids has proven to be a difficult engineering task. This is largely due to a very slow normal zone propagation in coated conductors that leads to formation of localized hotspots while the rest of the conductor remains in the superconducting state. We propose an original method of quench and hotspot detection for 2G wires and coils that is based upon local magnetic sensing and takes advantage of 2G wire planar geometry. We demonstrate our technique experimentally and show that its sensitivity is superior to the known voltage detection scheme. A unique feature of the method is its capability to remotely detect instant degradation of the wire critical current even before a normal zone is developed within the conductor. Various modifications of the method applicable to practical device configurations are discussed.

  2. Orthodontic Class II:1 treatment-efficiency and outcome quality of Herbst-multibracket appliance therapy.

    Science.gov (United States)

    Bock, N; Ruehl, J; Ruf, S

    2017-12-08

    The aim of this retrospective investigation was to assess the efficiency and outcome quality of Class II:1 treatment (Tx). The investigation is based on the evaluation of all Class II:1 patients that ever (1986-2014) started Tx with a Herbst appliance and subsequently a multibracket appliance (MBA) at the study center. Study casts from before Tx, after Herbst-MBA Tx, and (if available) after ≥ 24 months of retention were evaluated using the Peer Assessment Rating (PAR) index, the Ahlgren scale, and standard occlusal variables. In total, 526 Class II:1 patients with a mean pre-Tx age of 14.4 years (range 9.8-44.4) had received Herbst-MBA Tx; 18 patients discontinued Tx before completion. For 240 patients, data from ≥ 24 months of retention were available. The pre-Tx PAR score of 32.4 ± 8.83 was reduced to 8.0 ± 4.51 during Tx. A slight increase to 8.8 ± 5.11 occurred during retention. The percentage of patients which could be assigned to the category "greatly improved" was 62% after Tx and 57% after retention; only 2-3% had to be assigned to the category "worse/no different." The outcome ratings according to the Ahlgren scale revealed 17% excellent, 35% good, 45% satisfactory, and 3% unsuccessful results. Class II:1 Tx using Herbst-MBA is an efficient approach in orthodontic care. During a mean active Tx period of 2 years, high-quality results can be obtained in the majority of patients. The present investigation is the first to investigate a large unselected cohort of consecutive Herbst-MBA patients to determine representative data on the efficiency and the outcome quality of this Tx approach.

  3. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  4. IEE wiring regulations explained and illustrated

    CERN Document Server

    Scaddan, Brian

    2013-01-01

    The IEE Wiring Regulations Explained and Illustrated, Second Edition discusses the recommendations of the IEE Regulations for the Electrical Equipment of Buildings for the safe selection or erection of wiring installations. The book emphasizes earthing, bonding, protection, and circuit design of electrical wirings. The text reviews the fundamental requirements for safety, earthing systems, the earth fault loop impedance, and supplementary bonding. The book also describes the different types of protection, such as protection against mechanical damage, overcurrent, under voltage (which prevents

  5. Correction of deep overbite and gummy smile by using a mini-implant with a segmented wire in a growing Class II Division 2 patient.

    Science.gov (United States)

    Kim, Tae-Woo; Kim, Hyewon; Lee, Shin-Jae

    2006-11-01

    A boy, aged 10.5 years, with a Class II molar relationship and a very deep overbite, complaining of a gummy smile and anterior crowding, was treated nonextraction with a mini-implant and Twin-block and edgewise fixed appliances. Severely extruded and retroclined maxillary incisors were intruded and proclined with a nickel-titanium closed-coil spring anchored to a mini-implant and segmented wires; this resolved the gummy smile and deep overbite efficiently without extruding the maxillary molars or opening the mandible. The mandibular incisors were proclined without direct orthodontic force during intrusion of the maxillary incisors; this helped the nonextraction treatment of mandibular incisor crowding. The Twin-block appliance with high-pull headgear promoted mandibular growth, restrained maxillary growth, and changed the canine and molar relationship from Class II to Class I. The patient's overbite and overjet were overtreated, and, 1 year postretention, the patient maintained a good overbite and overjet.

  6. Minimisation of the wire position uncertainties of the new CERN vacuum wire scanner

    CERN Document Server

    AUTHOR|(CDS)2069346; Barjau Condomines, A

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new fast wire scanner is foreseen to measure small emittance beams throughout the LHC injector chain, which demands a wire travelling speed up to 20 ms-1 and position measurement accuracy of the order of a few microns. The vibrations of the mechanical parts of the system, and particularly the vibrations of the thin carbon wire, were identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations is a high priority for the design and operation of the new device. This document presents the work performed to understand the main causes of the wire vibrations observed in one of the existing wire scanner and the new proposed design.

  7. A new wire chamber front-end system, based on the ASD-8 B chip

    Energy Technology Data Exchange (ETDEWEB)

    Kruesemann, B.A.M. E-mail: kruesemann@kvi.nl; Bassini, R.; Ellinghaus, F.; Frekers, D.; Hagemann, M.; Hannen, V.M.; Heynitz, H. von; Heyse, J.; Rakers, S.; Sohlbach, H.; Woertche, H.J

    1999-07-11

    The Focal-Plane Polarimeter (FPP) for the Big-Bite Spectrometer van den Berg (Nucl. Instr. and Meth. B 99 (1995) 637ff) at the KVI requires the read-out of four large-area MWPCs and two VDCs with 3872 wires in total. The EUROSUPERNOVA collaboration (SNOVA) developed a digital 16 channel preamplifier front-end board, housing two amplifier-shaper-discriminatorchips ASD-8 B. The main features of this board are a fast single-wire readout, a high integration density, a low power consumption and compatibility to common instrumentation standards. The board represents the first successfully running application of the ASD-8 for wire chamber readout. (author)

  8. A new wire chamber front-end system, based on the ASD-8 B chip

    CERN Document Server

    Kruesemann, B A M; Ellinghaus, F; Frekers, D; Hagemann, M; Hannen, V M; Heynitz, H V; Heyse, J; Rakers, S; Sohlbach, H; Wörtche, H J

    1999-01-01

    The Focal-Plane Polarimeter (FPP) for the Big-Bite Spectrometer van den Berg (Nucl. Instr. and Meth. B 99 (1995) 637ff) at the KVI requires the read-out of four large-area MWPCs and two VDCs with 3872 wires in total. The EUROSUPERNOVA collaboration (SNOVA) developed a digital 16 channel preamplifier front-end board, housing two amplifier-shaper-discriminatorchips ASD-8 B. The main features of this board are a fast single-wire readout, a high integration density, a low power consumption and compatibility to common instrumentation standards. The board represents the first successfully running application of the ASD-8 for wire chamber readout. (author)

  9. Assessment of Human Exposure to Magnetic Fields Produced by Domestic Appliances (invited paper)

    International Nuclear Information System (INIS)

    Preece, A.W.; Kaune, W.T.; Grainger, P.; Golding, J.

    1999-01-01

    A study of 50 homes and their appliances examined whether a detailed appliance-use questionnaire and survey would yield data comparable with direct personal monitoring. This was coupled with direct measurement of the appliances in use to determine the field at 50 cm and 1 m. The findings were that individual time-weighted average (TWA) exposures calculated from questionnaire and activity diaries in conjunction with the appliance magnetic field were unrelated to actual personal exposure measurement. It was concluded that questionnaires are of little or no value for TWA estimation. However, peak exposure and short-term temporal variability could be modelled in subjects spending at least 15 min per day within 1 m of an operating microwave cooker or conventional cooker. This method could be extended to other appliances. (author)

  10. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  11. Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose:The Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL) provides a variety of research, design engineering and prototype fabrication services...

  12. Wire rope improvement program. Final report. [For draglines

    Energy Technology Data Exchange (ETDEWEB)

    Alzheimer, J.M.; Anderson, W.E.; Beeman, G.H.; Dudder, G.B.; Erickson, R.; Glaeser, W.A.; Jentgen, R.L.; Rice, R.R.; Strope, L.A.

    1981-09-01

    Activities in five major areas were undertaken during the WRIP: experiments using PNL-developed bend-over-sheave fatigue test machines to generate data on which to base a model for predicting large-diameter rope performance from that of small-diameter ropes; bend-over-sheave fatigue testing to determine differences in rope failure rates at varying rope loads; analyses to determine how wire ropes actually fail; development of a load sensor to record and quantity operational loads on drag and hoist ropes; and technology transfer activities to disseminate useful program findings to coal mine operators. Data obtained during the 6-year program support are included. High loads on wire ropes are damaging. As an adjunct, however, potentially useful countermeasures to high loads were identified. Large-diameter rope bend-over-sheave performance can be predicted from small-diameter rope test behavior, over some ranges.

  13. FE modeling of Cu wire bond process and reliability

    NARCIS (Netherlands)

    Yuan, C.A.; Weltevreden, E.R.; Akker, P. van den; Kregting, R.; Vreugd, J. de; Zhang, G.Q.

    2011-01-01

    Copper based wire bonding technology is widely accepted by electronic packaging industry due to the world-wide cost reduction actions (compared to gold wire bond). However, the mechanical characterization of copper wire differs from the gold wire; hence the new wire bond process setting and new bond

  14. 47 CFR 76.804 - Disposition of home run wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of home run wiring. 76.804 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.804 Disposition of home run wiring. (a) Building-by-building disposition of home run wiring. (1) Where an MVPD owns the home run wiring in an MDU...

  15. 76 FR 47518 - Energy Conservation Program: Treatment of “Smart” Appliances in Energy Conservation Standards and...

    Science.gov (United States)

    2011-08-05

    ...'' appliances, as well as other complementary technologies (such as smart meters) that may be necessary to the... Conservation Program: Treatment of ``Smart'' Appliances in Energy Conservation Standards and Test Procedures... analytical treatment of ``smart'' appliances in the development of DOE's energy conservation standards, as...

  16. Intra-wire resistance and AC loss in multi-filamentary MgB2 wires

    NARCIS (Netherlands)

    Zhou, Chao; Offringa, Wietse; Bergen, Anne-Henriette; Wessel, Wilhelm A.J.; Krooshoop, Hendrikus J.G.; Dhalle, Marc M.J.; Sumption, M.D.; Collings, E.W.; Rindfleisch, M.; Tomsic, M.; ten Kate, Herman H.J.; Nijhuis, Arend

    2013-01-01

    Intra-wire resistance and AC loss of various multi-filamentary MgB2 wires with filaments surrounded by Nb barriers have been measured and analyzed. The intra-wire resistance is measured with a direct four-probe voltage–current method at various temperatures. The AC loss is acquired by both vibrating

  17. THERMO-MECHANICALLY PROCESSED ROLLED WIRE FOR HIGH-STRENGTH ON-BOARD WIRE

    Directory of Open Access Journals (Sweden)

    V. A. Lutsenko

    2011-01-01

    Full Text Available It is shown that at twisting of wire of diameter 1,83 mm, produced by direct wire drawing of thermomechanically processed rolled wire of diameter 5,5 mm of steel 90, metal stratification is completely eliminated at decrease of carbon, manganese and an additional alloying of chrome.

  18. ECAE-processed Cu-Nb and Cu-Ag nanocomposite wires for pulse magnet applications

    International Nuclear Information System (INIS)

    Edgecumbe Summers, T.S.; Walsh, R.P.; Pernambuco-Wise, P.

    1997-01-01

    Cu-Nb and Cu-Ag nanocomposites have recently become of interest to pulse magnet designers because of their unusual combination of high strength with reasonable conductivity. In the as-cast condition, these conductors consist of two phases, one of almost pure Nb (or Ag) and the other almost pure Cu. When these castings are cold worked as in a wire-drawing operation for example, the two phases are drawn into very fine filaments which produce considerable strengthening without an unacceptable decrease in conductivity. Unfortunately, any increase in strength with operations such as wire drawing is accompanied by a reduction in the cross section of the billet, and thus far, no wires with strengths on the order of 1.5 GPa or more have been produced with cross sections large enough to be useful in magnet applications. Equal Channel Angular Extrusion (ECAE) is an innovative technique which allows for the refinement of the as-cast ingot structure without a reduction in the cross sectional dimensions. Samples processed by the ECAE technique prior to wire drawing should be stronger at a given wire diameter than those processed by wire drawing alone. The tensile properties of wire-drawn Cu-18%Nb and Cu-25%Ag both with and without prior ECAE processing were tested and compared at both room temperature and 77K. All samples were found to have resistivities consistent with their strengths, and the strengths of the ECAE-processed wires were significantly higher than their as-cast and drawn counterparts. Therefore, with ECAE processing prior to wire drawing, it appears to be possible to make high-strength conductors with adequately large cross sections for pulse magnets

  19. EDITORIAL More than a wire More than a wire

    Science.gov (United States)

    Demming, Anna

    2010-10-01

    Nanowires are the natural evolution of the connections in circuits when scaled down to nanometre sizes. On closer inspection, of course, the role of nanowires in developing new technologies is much more than just a current-bearing medium. By sizing the diameters of these objects down to the nanoscale, their properties become increasingly sensitive to factors such as the gas composition, temperature and incident light of their surrounding environment, as well as defects and variations in diameter. What becomes important in modern electronics innovations is not just what is connected, but how. Nanowires had already begun to attract the attention of researchers in the early 1990s as advances in imaging and measurement devices invited researchers to investigate the properties of these one-dimensional structures [1, 2]. This interest has sparked ingenious ways of fabricating nanowires such as the use of a DNA template. A collaboration of researchers at Louisiana Tech University in the US hs provided an overview of various methods to assemble conductive nanowires on a DNA template, including a summary of different approaches to stretching and positioning the templates [3]. Work in this area demonstrates a neat parallel for the role of DNA molecules as the building blocks of life and the foundations of nanoscale device architectures. Scientists at HP Labs in California are using nanowires to shrink the size of logic arrays [4]. One aspect of electronic interconnects that requires particular attention at nanoscale sizes is the effect of defects. The researchers at HP Labs demonstrate that their approach, which they name FPNI (field-programmable nanowire interconnect), is extremely tolerant of the high defect rates likely to be found in these nanoscale structures, and allows reduction in size and power without significantly sacrificing the clock rate. Another issue in scaling down electronics is the trend for an increasing resistivity with decreasing wire width. Researchers

  20. Comparison of PIV and Hot-Wire statistics of turbulent boundary layer

    International Nuclear Information System (INIS)

    Dróżdż, A; Uruba, V

    2014-01-01

    The paper shows a cross checking of turbulent boundary layer measurements using large field of view PIV and hot-wire anemometry techniques. The time-resolved PIV method was used for the experiments. The measuring plane was oriented perpendicularly to the wall and parallel to the mean flow. Hot wire measurement has been performed using the special probe with perpendicular hot wire. The HW point measurements were performed in the same place as PIV experiments. The hot-wire probe has the wire length of l + < 20 in considered range of Reynolds numbers. Various evaluation methods were applied on PIV data. The profiles of statistical characteristics of streamwise velocity components were evaluated from the data. Mean values, standard deviations as well as skewness and kurtosis coefficients were compared for a few values of Re θ . Reynolds number ranges from 1000 to 5500. The result shows that with the increasing Reynolds number the attenuation of fluctuations maximum in PIV measurements occurs with respect to Hot-Wire measurements, however representation of velocity fluctuations using the PIV method is satisfactory. The influence of wall-normal fluctuation component on Hot-Wire near wall peak was also investigated.

  1. Long-Wearing Wire Guide For Welding Torch

    Science.gov (United States)

    Gutow, David A.; Burley, Richard K.; Gilbert, Jeffrey L.; Fogel, Irving

    1992-01-01

    Insert for wire-guide tube on tungsten/inert-gas welding apparatus extends life of guide tube and increases accuracy of weld. Hardened insert resists wear by sliding tungsten wire. Chamfer guides wire into insert.

  2. Premaxillary distraction osteogenesis with an individual tooth-borne appliance.

    Science.gov (United States)

    Bengi, A Osman; Gürton, A Omit; Okcu, Kemal Murat; Aydintug, Yavuz Sinan

    2004-06-01

    Distraction osteogenesis defines a technique of bone generation and osteosynthesis by the distraction of native preexisting bone. The technique offers a promising treatment alternative for patients with maxillary hypoplasia and a retrognathic mandible. In this case report, the steps in the treatment of an 18.2-year-old girl with premaxillary hypoplasia and anterior crossbite are described. The patient was treated with a distraction osteogenesis technique, and premaxillary advancement was performed using an individual tooth-borne distraction device. The surgical operation consisted of a classical segmental maxillary osteotomy carefully respecting the palatal periosteum. The distractor was cemented in the mouth after the surgical procedures. The patient was observed during a seven-day latency period, after which the device was activated 0.5 mm every 12 hours. The anterior crossbite was eliminated in one week, and the treatment was finished with fixed orthodontic appliances.

  3. Issues in federal preemption of state appliance energy efficiency regulations

    Energy Technology Data Exchange (ETDEWEB)

    Fang, J.M.; Balistocky, S.; Schaefler, A.M.

    1982-12-01

    The findings and conclusions of the analysis of the various issues involved in the federal preemption of state regulations for the DOE no standard rule on covered appliances are summarized. The covered products are: refrigerators, refrigerator-freezers, freezers, clothes dryers, kitchen ranges and ovens, water heaters (excluding heat pump water heaters), room air conditioners, central air conditioners (excluding heat pumps), and furnaces. A detailed discussion of the rationale for the positions of groups offering comment for the record is presneted. The pertinent categories of state and local regulations and programs are explained, then detailed analysis is conducted on the covered products and regulations. Issues relating to the timing of preemption of state regulations are discussed, as well as issues relating to burden of proof, contents of petitions for exemptions from preemption, criteria for evaluating petitions, and procedural and other issues. (LEW)

  4. Inventory of usage pattern for wood burning appliances

    International Nuclear Information System (INIS)

    Cooper, David; Joeborn, Inger; Sjoedin, Aake; Munkhammar, Inger; Gustavsson, Lennart

    2005-02-01

    The Swedish Environmental Research Institute (IVL) in co-operation with the Swedish National Testing and Research Institute (SP) and Statistics Sweden (SCB) have investigated the use of domestic wood burning for wood stoves and open fireplaces. The results from a closer examination of existing national energy statistics for residential heating has enabled a division of the average consumption of firewood for each house by the category 'fireplace for open fire' and 'tiled stove/heating stove/fireplace for wood'. The estimation of emissions can therefore be improved by differentiating emission factors for different wood stoves and open fireplaces. Today, only one emission factor is used. An insight into general firing procedures, wood storage routines etc. was investigated using a questionnaire for the Teleborg area of the city Vaexjoe. The results of this study provide a foundation for further work, which will subsequently enable improvements for emission inventories on small-scale biomass combustion from household appliances

  5. Contextual Mobile Learning: A Step Further to Mastering Professional Appliances

    Directory of Open Access Journals (Sweden)

    René Chalon

    2007-10-01

    Full Text Available In this paper we describe our approach whose objective is to apply MOCOCO concepts to e-learning. After a short presentation of MOCOCO (Mobility, Cooperation, Contextualization and IMERA (Mobile Interaction in the Augmented Real Environment principles we will discuss their use in a project called HMTD (Help Me To Do whose aim is to use wearable computer for a framework of activities of better use, maintenance and repairing of professional appliances. We will successively describe m-learning scope, contextualization and cooperation advantages as well as learning methods. A case study of configuration of wearable computer and its peripherals, taking into account context, in-situ storage, traceability and regulation in these activities finishes this paper.

  6. 29 CFR 1919.79 - Wire rope.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Wire rope. 1919.79 Section 1919.79 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... recommended by the equipment or the wire rope manufacturer due to actual working condition requirements. In...

  7. Automatic inspection of railway overhead wires

    NARCIS (Netherlands)

    Smorenburg, C.; Valkenburg, A.L.G. van

    1988-01-01

    For the Netherlands railway company a system for inspection of the degree of wear of the contact wires is being developed. With an active sensor the reflective under-surface of the overhead wire is illuminated with a laserbeam and reflected radiation is detected by fast CCD detectors. With the

  8. Wire compensation: Performance, SPS MDs, pulsed system

    CERN Document Server

    Dorda, U

    2008-01-01

    A wire compensation (BBLR) scheme has been proposed in order to improve the long range beam-beam performance of the nominal LHC and its phase 1 and phase 2 upgrades[1]. In this paper we present experimental experience of the CERN SPS wires (BBLR) and report on progress with the RF BBLR.

  9. WIRED magazine announces rave awards nominees

    CERN Multimedia

    2002-01-01

    WIRED Magazine has anounced the nominees for its fourth annual WIRED Rave Awards, celebrating innovation and the individuals transforming commerce and culture. Jeffrey Hangst of the University of Aarhus has been nominated in the science category, for his work on the ATHENA Experiment, CERN (1/2 page).

  10. Kirschner Wire Breakage during Removal Requiring Retrieval

    Directory of Open Access Journals (Sweden)

    Kai Yuen Wong

    2016-01-01

    Full Text Available Kirschner wires (K-wires are widely used for fixation of fractures and dislocations in the hand as they are readily available, reliable, and cost-effective. Complication rates of up to 18% have been reported. However, K-wire breakage during removal is rare. We present one such case illustrating a simple technique for retrieval. A 35-year-old male presented with a distal phalanx fracture of his right middle finger. This open fracture was treated with K-wire fixation. Postoperatively, he developed a pin site infection with associated finger swelling. The K-wire broke during removal with the proximal piece completely retained in his middle phalanx. To minimise risk of osteomyelitis, the K-wire was removed with a novel surgical technique. He had full return of hand function. Intraoperative K-wire breakage has a reported rate of 0.1%. In our case, there was no obvious cause of breakage and the patient denied postoperative trauma. On the other hand, pin site infections are much more common with reported rates of up to 7% in the hand or wrist. K-wire fixation is a simple method for bony stabilisation but can be a demanding procedure with complications often overlooked. It is important to be aware of the potential sequelae.

  11. Hot-wire anemometer for spirography.

    Science.gov (United States)

    Plakk, P; Liik, P; Kingisepp, P H

    1998-01-01

    The use of a constant temperature hot-wire anemometer flow sensor for spirography is reported. The construction, operating principles and calibration procedure of the apparatus are described, and temperature compensation method is discussed. Frequency response is studied. It is shown that this hot-wire flow transducer satisfies common demands with respect to accuracy, response time and temperature variations.

  12. Evaluation of heating performances and associated variability of domestic cooking appliances (oven-baking and pan-frying)

    International Nuclear Information System (INIS)

    Cernela, Jérémie; Heyd, Bertrand; Broyart, Bertrand

    2014-01-01

    By comparison with those in industry, domestic cooking processes are rarely studied with respect to heat transfer although they can drastically modify the quality of heated products. In order to compensate for this lack of information in the literature, the aim of this work was to propose test procedures to evaluate the variability of domestic appliance heating performances in the case of oven-baking and pan-frying. The measurements included the continuous recording of pan temperature during pan-frying using different types of hobs (electric, halogen, gas, induction) and pans; the continuous recording of air temperature and measurement of the convective heat transfer coefficient and equivalent radiative temperature during oven-baking using different types of ovens. The results revealed broad variations in heating conditions depending on the type of appliance used and on consumer behaviour. For pan-frying, it was shown that pan temperature varied constantly during heating. From an initial value of 200 °C and a given product load, it could fall to 150 °C or rise to 330 °C at medium or high heat, respectively. For oven-baking, heating was sometimes performed at an actual air temperature that differed considerably from the air temperature set on the oven. These measurements also showed relatively low convective heat transfer coefficient values, ranging from 6 W/m 2 K under free convection to 16 W/m 2 K under forced convection. -- Highlights: • Domestic oven baking and pan-frying are thermally chracterised. • Quantitative data on the variability of domestic heating conditions are given. • Variability due to domestic appliances and cooking practices is very large

  13. A cephalometric comparison of treatment with the Twin-block and stainless steel crown Herbst appliances followed by fixed appliance therapy.

    Science.gov (United States)

    Schaefer, Abbie T; McNamara, James A; Franchi, Lorenzo; Baccetti, Tiziano

    2004-07-01

    This study compared the effects of 2 treatment protocols for correcting Class II disharmony. The first phase of treatment consisted of functional jaw orthopedics with either the Twin-block or the stainless-steel crown Herbst appliance; the second phase consisted of comprehensive fixed-appliance therapy in both protocols. Each of the 2 samples comprised 28 consecutively treated Class II patients. The mean age at the start of treatment was approximately 12 years, and the mean age at the end of the treatment was approximately 14.5 years in both groups. The duration of the treatment phase with the functional appliance was approximately 13 months, and the duration of fixed-appliance therapy was approximately 15 months in both groups. The sex distribution was identical in the 2 groups. Lateral cephalograms were analyzed at the start of treatment (T1) and at the end of the overall treatment protocol (T2). Nonparametric statistics were used for comparisons of starting forms and of the T1-T2 changes between the 2 treatment groups. The stainless-steel crown Herbst appliance and the Twin-block appliance produced very similar therapeutic modifications in Class II patients, although the Twin-block group exhibited almost 2 mm greater correction of the maxillomandibular differential than did the crown Herbst group. The treatment effects of both protocols led to a normalization of the dentoskeletal parameters at the end of the overall treatment period. Twin-block therapy also induced a greater increase in the height of the mandibular ramus (posterior facial height). Overall, only minor differences were detected in the treatment and posttreatment effects of a compliance-free (crown Herbst) and a noncompliance-free (Twin-block) appliance for correcting Class II disharmony.

  14. Effects of fixed appliances in correcting Angle Class II on the depth of the posterior airway space: FMA vs. Herbst appliance--a retrospective cephalometric study.

    Science.gov (United States)

    Kinzinger, Gero; Czapka, Kathrin; Ludwig, Björn; Glasl, Bettina; Gross, Ulrich; Lisson, Jörg

    2011-08-01

    The objective of this retrospective study based on the metric evaluation of lateral cephalograms was to investigate the extent to which treatment with two different fixed appliances for the correction of Angle Class II influenced the morphology of the extrathoracic airway space (the posterior airway space, PAS). A total of 43 patients with Angle Class II malocclusion were classified into two groups according to the appliance used for treatment: the functional mandibular advancer (FMA; n = 18) or the Herbst appliance (n = 25). Lateral cephalograms were taken of each patient at the start of functional jaw orthopedic treatment (time point T1) and at its completion (time point T2). Specific distances and angles were measured and analyzed in a cephalometric analysis. We observed major differences among the 43 patients in the depth of the posterior airway space during treatment with fixed appliances for Angle Class II correction. Regression analysis revealed that changes in sagittal and vertical positions had different effects on the depth of specific PAS sections: increases in anterior facial height are associated proportionately with increases in PAS width, particularly in the upper region. On the other hand, increases in posterior facial height and in the mandible's forward displacement correlated inversely to the decreases in depth, particularly in the central and lower PAS regions. The two treatment appliances (FMA, Herbst appliance) had the same effects on extrathoracic airway depth. Analyses of lateral cephalograms indicate that Angle Class II treatment with fixed appliances does not prevent sleep apnea in patients at risk. Nevertheless, this study does not permit absolutely reliable conclusions about the dimensions of the pharyngeal airway space. As the lateral cephalogram provides good images of structures in the midsagittal plane but is incapable of imaging the transverse dimension, there is an automatic lack of information concerning the precise

  15. Design and manufacturing of patient-specific orthodontic appliances by computer-aided engineering techniques.

    Science.gov (United States)

    Barone, Sandro; Neri, Paolo; Paoli, Alessandro; Razionale, Armando Viviano

    2018-01-01

    Orthodontic treatments are usually performed using fixed brackets or removable oral appliances, which are traditionally made from alginate impressions and wax registrations. Among removable devices, eruption guidance appliances are used for early orthodontic treatments in order to intercept and prevent malocclusion problems. Commercially available eruption guidance appliances, however, are symmetric devices produced using a few standard sizes. For this reason, they are not able to meet all the specific patient's needs since the actual dental anatomies present various geometries and asymmetric conditions. In this article, a computer-aided design-based methodology for the design and manufacturing of a patient-specific eruption guidance appliances is presented. The proposed approach is based on the digitalization of several steps of the overall process: from the digital reconstruction of patients' anatomies to the manufacturing of customized appliances. A finite element model has been developed to evaluate the temporomandibular joint disks stress level caused by using symmetric eruption guidance appliances with different teeth misalignment conditions. The developed model can then be used to guide the design of a patient-specific appliance with the aim at reducing the patient discomfort. At this purpose, two different customization levels are proposed in order to face both arches and single tooth misalignment issues. A low-cost manufacturing process, based on an additive manufacturing technique, is finally presented and discussed.

  16. Immunoexpression of cytokeratin 19 in oral swab from fixed orthodontic appliance users

    Directory of Open Access Journals (Sweden)

    Dwi Mutia Ramdhini

    2007-11-01

    Full Text Available The use of fixed orthodontic appliances can improve someone's mastication, speech and appearance. However, this appliance acts as a strange object that may cause irritation to the mucosa epithelial of oral cavity, because of the friction and pressure from the components of the fixed orthodontic appliances which are in direct contact with the oral mucosa. Irritation in the oral mucosa could stimulate the increase of cytokeratin. The appearance of cytokeratin is then used to identify the condition of these cells. This study was a descriptive research to find the expression of cytokeratin 19 with immunohistochemical method in oral mucosa epithelial of fixed orthodontic appliances users. Sample in this study was chosen from 30 fixed orthodontic appliances users. The result of this study was determined by calculating the number of positive cells (brown, compared with total number of cells. The account of positive cells would present the reaction of the epithelial cells according to the inflamation stage which caused by the use of orthodontic appliances. As a conclusion of this study, the use of fixed orthodontic appliances may cause changes in epithelial mucosa which form an adaptation process by increasing the number of progenitor cells marked by cytokeratin 19.

  17. Survival of palatal miniscrews used for orthodontic appliance anchorage: a retrospective cohort study.

    Science.gov (United States)

    Karagkiolidou, Angeliki; Ludwig, Björn; Pazera, Pawel; Gkantidis, Nikolaos; Pandis, Nikolaos; Katsaros, Christos

    2013-06-01

    The purpose of this study was to examine the overall success of miniscrews inserted in the paramedian palatal region for support of various appliances during orthodontic treatment. The patients received 1 or 2 miniscrews in the paramedian anterior palate of 8.0-mm length and 1.6-mm diameter placed during orthodontic treatment by the same experienced orthodontist. In total, 196 patients (121 girls, 75 boys; median age, 11.7; interquartile range, 3.7) who received 384 miniscrews were evaluated. Two hundred four miniscrews were used with rapid palatal expansion appliances, 136 with appliances for distalization of posterior teeth, and 44 with other appliances, such as transpalatal arches for tooth stabilization. The overall survival of the miniscrews was excellent (97.9%) in the cases examined. Cox regression analysis showed no difference in the overall survival rates of miniscrews loaded with different appliances for sex (hazard ratio, 0.95; 95% confidence interval, 0.71-1.27; P = 0.73) after adjusting for appliance and age. This study shows that miniscrews placed in the paramedian anterior palate for supporting various orthodontic appliances have excellent survival. Copyright © 2013 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  18. Effect of thermoplastic appliance thickness on initial stress distribution in periodontal ligament

    Directory of Open Access Journals (Sweden)

    De-Shin Liu

    2015-04-01

    Full Text Available A numerical investigation into the initial stress distribution induced within the periodontal ligament by thermoplastic appliances with different thicknesses is performed. Based on the plaster model of a 25-year-old male patient, a finite element model of the maxillary lateral incisors and their supporting structures is constructed. In addition, four finite element models of thermoplastic appliances with different thicknesses in the range of 0.5–1.25 mm are also constructed based on the same plaster model. Finite element analysis simulations are performed to examine the effects of the force delivered by the thermoplastic appliances on the stress response of the periodontal ligament during the elastic recovery process. The results show that the stress induced in the periodontal ligament increases with an increasing appliance thickness. For example, the stress triples from 0.0012 to 0.0038 MPa as the appliance thickness is increased from 0.75 to 1.25 mm. The results presented in this study provide a useful insight into as a result of the compressive and tensile stresses induced by thermoplastic appliances of different thicknesses. Moreover, the results enable the periodontal ligament stress levels produced by thermoplastic appliances of different thicknesses to be reliably estimated.

  19. Guide Wire Entrapment during Central Venous Catheterization

    Directory of Open Access Journals (Sweden)

    Kyung Woo Kim

    2014-05-01

    Full Text Available We experienced a case of venous vessel wall entrapment between the introducer needle and the guide wire during an attempt to perform right internal jugular vein (IJV catheterization. The guide wire was introduced with no resistance but could not be withdrawn. We performed ultrasonography and C-arm fluoroscopy to confirm the entrapment location. We assumed the introducer needle penetrated the posterior vessel wall during the puncture and that only the guide wire entered the vein; an attempt to retract the wire pinched the vein wall between the needle tip and the guide wire. Careful examination with various diagnostic tools to determine the exact cause of entrapment is crucial for reducing catastrophic complications and achieving better outcomes during catheterization procedures.

  20. Single wire drift chamber design

    Energy Technology Data Exchange (ETDEWEB)

    Krider, J.

    1987-03-30

    This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 ..mu..m rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles.

  1. Upper removable appliance or Jones Jig for distalizing first molars? A randomized clinical trial.

    Science.gov (United States)

    Paul, L D; O'Brien, K D; Mandall, N A

    2002-11-01

    To compare the effectiveness of two intra-oral methods of distalizing upper first permanent molars: an upper removable appliance (URA) and a Jones Jig. Twelve patients were randomly allocated to URA treatment and 11 patients to a Jones Jig. Upper study models were collected at the start of treatment and after 6 months of appliance wear. The amount of distal movement, tipping and rotation of the upper first permanent molars and mesial movement of the upper first permanent premolars was measured using a reflex metrograph. There were no statistically significant differences between the two treatment methods for any of the outcome measures (P Jig as a non-compliance appliance.

  2. E-waste Management in Japan: a focus on Appliance Recycling

    OpenAIRE

    Yoshida, Fumikazu; Yoshida, Haruyo

    2013-01-01

    As 10 years have passed since the Japanese home electrical appliance recycling system came into operation, the results of the system have become clearer, and it is therefore time for us to analyze and evaluate its performance in terms of both the environment and the economy. The system covers 4 specified house appliances, and although roughly 2/3 of these discarded appliances are collected and recycled formally by the manufactures, the greater part of the remaining 1/3 is exported as used ite...

  3. A New Orthodontic Appliance with a Mini Screw for Upper Molar Distalization.

    Science.gov (United States)

    Ozkalayci, Nurhat; Yetmez, Mehmet

    2016-01-01

    The aim of this study is to present a new upper molar distalization appliance called Cise distalizer designed as intraoral device supported with orthodontic mini screw for upper permanent molar distalization. The new appliance consists of eight main components. In order to understand the optimum force level, the appliance under static loading is tested by using strain gage measurement techniques. Results show that one of the open coils produces approximately 300 gr distalization force. Cise distalizer can provide totally 600 gr distalization force. This range of force level is enough for distalization of upper first and second molar teeth.

  4. A New Orthodontic Appliance with a Mini Screw for Upper Molar Distalization

    Directory of Open Access Journals (Sweden)

    Nurhat Ozkalayci

    2016-01-01

    Full Text Available The aim of this study is to present a new upper molar distalization appliance called Cise distalizer designed as intraoral device supported with orthodontic mini screw for upper permanent molar distalization. The new appliance consists of eight main components. In order to understand the optimum force level, the appliance under static loading is tested by using strain gage measurement techniques. Results show that one of the open coils produces approximately 300 gr distalization force. Cise distalizer can provide totally 600 gr distalization force. This range of force level is enough for distalization of upper first and second molar teeth.

  5. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Appliances

    Energy Technology Data Exchange (ETDEWEB)

    Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Ahlfeldt, Christopher [Navigant Consulting, Inc., Burlington, MA (United States); Hiraiwa, Hirokazu [Navigant Consulting, Inc., Burlington, MA (United States); Sathe, Amul [Navigant Consulting, Inc., Burlington, MA (United States); Sutherland, Timothy [Navigant Consulting, Inc., Burlington, MA (United States)

    2009-12-01

    This study characterizes and assesses the appliances used in commercial buildings. The primary objectives of this study were to document the energy consumed by commercial appliances and identify research, development and demonstration (RD&D) opportunities for efficiency improvements, excluding product categories such as HVAC, building lighting, refrigeration equipment, and distributed generation systems. The study included equipment descriptions, characteristics of the equipment’s market, national energy consumption, estimates of technical potential for energy-saving technologies, and recommendations for U.S. Department of Energy programs that can promote energy savings in commercial appliances.

  6. Electronic commerce: wiring the coal industry for new data technology

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.A.

    1998-07-01

    Industry pundits predict that coal by wire may some day replace much of the industry`s long-distance shipping requirements and their attendant costs, but data by wire, also known as electronic commerce (EC) can today offer coal producers and customers the means to gather and send large volumes of data cheaply and quickly. EC`s major components - electronic data interchange (EDI), bar-coding, smart codes, radio frequency `D`, and the internet - can reduce costs in equipment-intensive industries such as mining. The US National Mining Association sponsored a forum to discuss these alternatives at its 1998 Electronic Commerce Summit held in Tuscon, Arizona, 18-20 May. A report is given of discussions at the forum and contacts are given for sources of EDI information.

  7. Genetic programming techniques for thin-wire antennas

    Science.gov (United States)

    O'Donnell, Terry H.

    2007-04-01

    Simple genetic algorithm optimizations often utilize fixed-length chromosomes containing a predefined set of parameters to be optimized. While such algorithms have successfully created electrically small narrow-band and large wide-band military antennas, they require the antenna designer to have a fairly concrete antenna representation prior to exercising the genetic algorithm. In this research we investigate the use of genetic programming (GP) techniques to "program" the design of simple thin-wire antennas. Genetic programming techniques offer the potential to create random, multi-arm, multi-dimension antennas from variable length, tree-like chromosomes. We present a new genetic programming paradigm for creating multi-branched, thin-wire, genetic antennas and describe how GP commands are represented and decoded into physical antenna structures. We present preliminary results obtained from this algorithm showing evolutions along Pareto fronts representing antenna electrical size, VSWR, and antenna quality factor (Q).

  8. Minimum quench energy measurement for superconducting wires

    International Nuclear Information System (INIS)

    Seo, K.; Morita, M.; Nakamura, S.; Yamada, T.; Jizo, Y.

    1996-01-01

    The authors have developed a new method of measuring minimum quench energy (MQE) of superconducting wire. There have been conventional methods using heating wires, whose diameters are ∼0.1mm and are glued by epoxy resin. When they induce a pulse heat to superconducting wires, a duration of the pulse must be several hundreds micro seconds to demonstrate actual disturbances (for instance wire motion) in a superconducting magnet. In spite of this fact, thermal diffusion time constants of the conventional heaters are larger than the duration of the actual disturbance, because of these electrical insulator of the heating wire and the epoxy bind. Therefore, this kind of heater is not able to demonstrate the actual disturbance. To solve this problem, they have proposed a new constitution of a heater. In the method, heat generation is introduced in high resistive layer on a surface of a superconducting wire. The high resistive layer is consist of carbon paste. The thickness of the carbon paste layer is ∼20microm, thus a time constant of this heater is expected to be small enough to demonstrate the actual disturbance. Adopting the new method to the MQE measurement, they successfully evaluate MQE of superconducting wires with high precision. Several results are introduced in this paper

  9. Wire pad chamber for LHCb muon system

    CERN Document Server

    Botchine, B; Lazarev, V A; Sagidova, N; Vorobev, A P; Vorobyov, A; Vorobyov, Alexei

    2000-01-01

    2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.

  10. Cephalometric study of Class II Division 1 patients treated with an extended-duration, reinforced, banded Herbst appliance followed by fixed appliances.

    Science.gov (United States)

    Tomblyn, Travis; Rogers, Michael; Andrews, Lee; Martin, Chris; Tremont, Timothy; Gunel, Erdogan; Ngan, Peter

    2016-11-01

    The Herbst appliance has been used in the treatment of Class II malocclusions with deficient mandibles. Various protocols, including different durations of the orthopedic treatment phase and stepwise advancement of the mandible, have been advocated for increasing the orthopedic effects. The objective of this study was to investigate the skeletal and dental changes in patients treated with a reinforced banded Herbst appliance for an extended duration and fixed appliance therapy. The study group consisted of 30 patients (16 boys, 14 girls; mean age, 12.3 ± 2.5 years) with Class II Division 1 malocclusions who were successfully treated with the new Herbst protocol followed by fixed appliances. Lateral cephalometric radiographs were taken before treatment, at the completion of Herbst treatment, and after removal of fixed appliances. The average treatment times were 1.5 ± 0.7 years for the Herbst treatment and 1.8 ± 0.5 years for the fixed appliances. A control Class II sample from the Bolton-Brush study was used to subtract growth from treatment changes to determine the appliance effect. Data were analyzed using analysis of variance and the Tukey-Kramer test. After the Herbst treatment, the incisal relationships of all subjects had been overcorrected to end-to-end relationships. Overjet was reduced by 7.2 mm after subtracting changes from growth. The skeletal contribution was 2.5 mm (35%), and the dental contribution was 4.7 mm (65%). The molar relationship was overcorrected to a more Class I relationship by 7.5 mm. The Wits appraisal was improved by 4.2 mm. Vertically, overbite was decreased by 3.3 mm. The maxillary and mandibular molars were extruded by 1 mm. The occlusal plane rotated clockwise by 5° with little change in the mandibular plane angle. After the treatment with fixed appliances, the overjet correction was maintained at 7.6 mm. The skeletal contribution was 2.9 mm (38%), and the dental contribution was 4.7 mm (62%). The molar

  11. Resonant tunneling of electrons in quantum wires

    International Nuclear Information System (INIS)

    Krive, I.V.; Shekhter, R.I.; Jonson, M.; Krive, I.V.

    2010-01-01

    We considered resonant electron tunneling in various nanostructures including single wall carbon nanotubes, molecular transistors and quantum wires formed in two-dimensional electron gas. The review starts with a textbook description of resonant tunneling of noninteracting electrons through a double-barrier structure. The effects of electron-electron interaction in sequential and resonant electron tunneling are studied by using Luttinger liquid model of electron transport in quantum wires. The experimental aspects of the problem (fabrication of quantum wires and transport measurements) are also considered. The influence of vibrational and electromechanical effects on resonant electron tunneling in molecular transistors is discussed.

  12. Problems associated with iridium-192 wire implants

    International Nuclear Information System (INIS)

    Arnott, S.J.; Law, J.; Ash, D.; Flynn, A.; Paine, C.H.; Durrant, K.R.; Barber, C.D.; Dixon-Brown, A.

    1985-01-01

    Three incidents are reported, from different radiotherapy centres, in which an implanted iridium-192 wire remained in the tissues of a patient after withdrawal of the plastic tubing in which it was contained. In each case the instrument used to cut the wire had probably formed a hook on the end of the wire which caused it to catch in the tissues. Detailed recommendations are made for avoiding such incidents in the future, the most important of which is that the patient should be effectively monitored after the supposed removal of all radioactive sources. (author)

  13. Development of a multimodal transportation educational virtual appliance (MTEVA) to study congestion during extreme tropical events.

    Science.gov (United States)

    2011-11-28

    In this study, a prototype Multimodal Transportation Educational Virtual Appliance (MTEVA) is developed to assist in transportation and cyberinfrastructure undergraduate education. This initial version of the MTEVA provides a graphical user interface...

  14. Poster Abstract: A Practical Model for Human-Smart Appliances Interaction

    DEFF Research Database (Denmark)

    Fürst, Jonathan; Fruergaard, Andreas; Johannesen, Marco Høvinghof

    2016-01-01

    for human-smart appliance interaction. We present a prototype implementation with an off-the-shelf smart lighting and heating system in a shared office space. Our approach minimizes the need for location metadata. It relies on a human-feedback loop (both sensor based and manual) to identify the optimal......Buildings are increasingly equipped with smart appliances that allow a fine grained adaption to personal comfort requirements. Such comfort adaption should be based on a human-feedback loop and not on a centralized comfort model. We argue that this feedback-loop should be achieved through local...... interaction with smart appliances. Two issues stand out: (1) How to impose logical locality when interacting with a smart appliance? (2) How to mediate conflicts between several persons in a room, or between building-wide policies and user preferences? We approach both problems by defining a general model...

  15. Home Appliances as Home Controllers: Concepts and Set-Top Box Implementation

    Directory of Open Access Journals (Sweden)

    Z. Jovanovic

    2010-11-01

    Full Text Available In this paper we present a novel softwarebased home control platform suitable as an extension to digital home appliances that are equipped with a CPU (settop boxes, home theatre systems, TV sets, gaming consoles, etc. By using an appliance they are already accustomed to, users become able to control lights, appliances and media playback in their homes. Intelligence and awareness are achieved with a support for execution of recipes – preprepared scripts that define timely actions and respond to triggers obtained from sensors. Software abstraction layer facilitates integration of any desired communication protocol. In our prototype, we supported Zigbee and DMX for light control, X10 for light/appliances control over power line, as well as Ethernet-based optical cameras as motion/presence sensors and UPnP/DLNA based equipment for distributed media playback.

  16. Technical Appliance in E-Learning: Student’s Perception on the Usage of Online Learning

    Directory of Open Access Journals (Sweden)

    Siti Sarah Mohd Johari

    2010-06-01

    Full Text Available The purpose of this study is to gain insights into student’s perception on the usage of technical appliances on online learning. The study took place in the Universiti Sains Malaysia (USM based on the sample of 1084 student s with the experiences of using E-learning Portal as one of the distance education academic programme. The students were surveyed on the participation needs based on respondent’s personal background, such as age, gender, ethnic groups, education streams and year-of-study. Results of the study showed even though most of the students felt uncertain about the technical appliances in E-learning Portal, the study illustrates the true nature of the student’s perceptions with respect to the functionality and effectiveness of technical appliance in E-learning Portal. This research is essential to elucidate the functions of technical appliances in facilitating the process of learning through the portal.

  17. Impacts of Imported Liquefied Natural Gas on Residential Appliance Components: Literature Review

    Energy Technology Data Exchange (ETDEWEB)

    Lekov, Alex; Sturges, Andy; Wong-Parodi, Gabrielle

    2009-12-09

    An increasing share of natural gas supplies distributed to residential appliances in the U.S. may come from liquefied natural gas (LNG) imports. The imported gas will be of a higher Wobbe number than domestic gas, and there is concern that it could produce more pollutant emissions at the point of use. This report will review recently undertaken studies, some of which have observed substantial effects on various appliances when operated on different mixtures of imported LNG. While we will summarize findings of major studies, we will not try to characterize broad effects of LNG, but describe how different components of the appliance itself will be affected by imported LNG. This paper considers how the operation of each major component of the gas appliances may be impacted by a switch to LNG, and how this local impact may affect overall safety, performance and pollutant emissions.

  18. Modified custom made J-hook for maxillary protraction in a rapid maxillary expansion appliance

    Directory of Open Access Journals (Sweden)

    Jithesh Kumar Kodoth

    2014-01-01

    Full Text Available A simple yet innovative attaching the J-hook along with an rapid maxillary appliance for the protraction of maxilla is presented. The proposed method not only simplifies construction but also is equally effective.

  19. Changes in 3D Midfacial Parameters after Biomimetic Oral Appliance Therapy in Adults

    Directory of Open Access Journals (Sweden)

    G Dave Singh

    2014-01-01

    Conclusion: These data support the notion that maxillary bone width and volume can be changed in nongrowing adults. Furthermore, midfacial redevelopment may provide a potentially-useful method of managing adults diagnosed with obstructive sleep apnea, using biomimetic, oral appliances.

  20. 78 FR 51100 - Appliance Standards and Rulemaking Federal Advisory Committee: Notice of Open Teleconference/Webinar

    Science.gov (United States)

    2013-08-20

    .../appliance_standards/asrac.html : Update on Commercial HVAC, Water Heating, and Refrigeration Certification... regarding commercial/industrial pumps working group. Any new business as discussed by the ASRAC committee...

  1. POSSIBLE ROLE OF INDOOR RADON REDUCTION SYSTEMS IN BACK-DRAFTING RESIDENTIAL COMBUSTION APPLIANCES

    Science.gov (United States)

    The article gives results of a computational sensitivity analysis conducted to identify conditions under which residential active soil depressurization (ASD) systems for indoor radon reduction might contribute to or create back-drafting of natural draft combustion appliances. Par...

  2. Correction of class III malocclusion using modified tandem appliance-two case reports

    Directory of Open Access Journals (Sweden)

    J Jeevarathan

    2013-01-01

    Full Text Available Skeletal discrepancies in growing children can have great physical and psychological impact on their appearance. These deformities require orthopedic correction at an appropriate age to avoid future extensive management. Managing a midfacial deficiency or true mandibular prognathism is perhaps the most challenging situation for the clinician. Many orthopedic appliances like chin cup, facemask, and so on have been advocated to correct class III malocclusion. The major problems with these appliances are physical appearance, skin irritation from the anchorage pads and hence, less patient compliance. We present management of class III malocclusion in two children with modified tandem appliance (MTA, which is an intraoral appliance, with no extraoral anchorage, and has better patient compliance and cooperation.

  3. Correction of class III malocclusion using modified tandem appliance-two case reports.

    Science.gov (United States)

    Jeevarathan, J; Koora, Kiran; Sudhakar, V; Muthu, M S; Prabhu, Rathna V

    2013-01-01

    Skeletal discrepancies in growing children can have great physical and psychological impact on their appearance. These deformities require orthopedic correction at an appropriate age to avoid future extensive management. Managing a midfacial deficiency or true mandibular prognathism is perhaps the most challenging situation for the clinician. Many orthopedic appliances like chin cup, facemask, and so on have been advocated to correct class III malocclusion. The major problems with these appliances are physical appearance, skin irritation from the anchorage pads and hence, less patient compliance. We present management of class III malocclusion in two children with modified tandem appliance (MTA), which is an intraoral appliance, with no extraoral anchorage, and has better patient compliance and cooperation.

  4. 76 FR 36908 - Draft Competition Rules for a Global Appliance Efficiency Award for Televisions

    Science.gov (United States)

    2011-06-23

    ... outreach to appliance and consumer electronics industry associations, this notice is intended to announce... counterparts from Australia, Canada, Japan, Sweden, and the United Kingdom. The Awards Working Group has...

  5. Evaluation of the Jones jig appliance for distal molar movement.

    Science.gov (United States)

    Brickman, C D; Sinha, P K; Nanda, R S

    2000-11-01

    The purpose of this study was to determine the effects of the Jones jig appliance on distal movement of maxillary molars and reciprocal effects on premolars and maxillary incisors. Cephalometric radiographs before and after orthodontic treatment of 72 consecutively treated patients, 46 females and 26 males, were measured to define treatment changes attributed to the Jones jig. Comparative measurements were made on a matched sample of 35 patients (20 females and 15 males) treated with cervical headgear by the same clinician. Both series of patients were treated to correct an Angle Class II molar relationship. The molar correction in the Jones jig patients consisted primarily of molar distal movement. Dental, soft tissue, and skeletal changes were evaluated and compared for significant differences between techniques. The results from the Jones jig sample showed the mean maxillary first molar distal movement was 2.51 mm, with distal tipping of 7.53 degrees. The mean reciprocal mesial movement of the maxillary premolar was 2.0 mm, with mesial tipping of 4.76 degrees. The maxillary first molar extruded 0.14 mm; the maxillary premolar extruded 1.88 mm. The maxillary second molars were also moved distally 2.02 mm and tipped distally 7.89 degrees. The longitudinal assessment (initial to completion of orthodontic treatment) showed significant differences between the Jones jig sample and the cervical headgear sample for lower lip to E-line and SNA. The Jones jig sample showed a mean decrease in lower lip to E-line of 0.25 mm versus 1.20 mm (P jig sample versus 1.20 degrees (P jig sample and cervical headgear sample did not show significant differences of the final position in either linear or angular measurements of the maxillary first molars and corresponding premolar-incisor anchor units. The Jones jig appliance demonstrated treatment results comparable with those of the sample treated with cervical headgear. The Jones jig sample demonstrated effective distal molar

  6. Efficacy of modified pendulum appliance for the correction of class II malocclusion: A clinical study

    OpenAIRE

    Monika Koul; Ayushi Singla; Anil Singla; Vivek Mahajan; Harupinder Singh Jaj; Priyanka Negi

    2017-01-01

    Introduction: The purpose of this prospective study was to analyze the efficiency of pendulum appliance for distalizing maxillary first molar while decreasing the anchorage loss by banding first and second premolar and making them one unit. Materials and Methods: The study group comprised of 20 patients (mean age 13 ± 2 years) who had skeletal Class I and Angle's Class II molar relation. Modified pendulum appliance was given to distalize maxillary first molar and to decrease the anchorage los...

  7. Mini-screws, a viable adjunct along with Incognito lingual appliance: A case series

    OpenAIRE

    Wei Lin; K K Fiona Pang; U T Sukie Wong; Viraj Doshi

    2015-01-01

    Invisible orthodontics have been around for too long, and with the advent of computer-aided design/computer-aided manufacturing technology appliances such as Incognito TM has made the whole treatment experience more pleasant and aesthetic. However, even in lingual orthodontics, biomechanics play the most important role, and the use of temporary anchorage devices (TADs) has made the whole treatment more effective and efficient. This article focuses on cases where TADs in lingual appliances pla...

  8. Optimal joint scheduling of electrical and thermal appliances in a smart home environment

    International Nuclear Information System (INIS)

    Shirazi, Elham; Zakariazadeh, Alireza; Jadid, Shahram

    2015-01-01

    Highlights: • Thermal appliances are scheduled based on desired temperature and energy prices. • A discomfort index has been introduced within the home energy scheduling model. • Appliances are scheduled based on activity probability and desired options. • Starting probability depends on the social random factor and consumption behavior. - Abstract: With the development of home area network, residents have the opportunity to schedule their power usage in the home by themselves aiming at reducing electricity expenses. Moreover, as renewable energy sources are deployed in home, a home energy management system needs to consider both energy consumption and generation simultaneously to minimize the energy cost. In this paper, a smart home energy management model has been presented in which electrical and thermal appliances are jointly scheduled. The proposed method aims at minimizing the electricity cost of a residential customer by scheduling various type of appliances considering the residents consumption behavior, seasonal probability, social random factor, discomfort index and appliances starting probability functions. In this model, the home central controller receives the electricity price information, environmental factors data as well as the resident desired options in order to optimally schedule appliances including electrical and thermal. The scheduling approach is tested on a typical home including variety of home appliances, a small wind turbine, photovoltaic panel, combined heat and power unit, boiler and electrical and thermal storages over a 24-h period. The results show that the scheduling of different appliances can be reached simultaneously by using the proposed formulation. Moreover, simulation results evidenced that the proposed home energy management model exhibits a lower cost and, therefore, is more economical.

  9. Load Balancing Integrated Least Slack Time-Based Appliance Scheduling for Smart Home Energy Management

    OpenAIRE

    Bhagya Nathali Silva; Murad Khan; Kijun Han

    2018-01-01

    The emergence of smart devices and smart appliances has highly favored the realization of the smart home concept. Modern smart home systems handle a wide range of user requirements. Energy management and energy conservation are in the spotlight when deploying sophisticated smart homes. However, the performance of energy management systems is highly influenced by user behaviors and adopted energy management approaches. Appliance scheduling is widely accepted as an effective mechanism to manage...

  10. Photovoltaic power supply for appliances and small systems. Final report; Photovoltaik fuer Geraete und Kleinsysteme. Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Roth, W.; Anton, L.; Benz, J.; Kaiser, R.; Kuhmann, J.; Puls, H.G.; Pfanner, N.; Schmidt, H.; Schulz, W.; Steinhueser, A.

    2002-06-01

    The economic prospects of PV power supply to appliances and small systems were investigated. The research project was aimed at improving the conditions for efficient development of appliances and small systems with photovoltaic power supply and autonomous systems not connected to the grid. Innovative products were developed and tested in cooperation with industrial organizations. The project is to help small and medium-sized organizations with a technological orientation and enhance technology transfer between science and industry.

  11. Changes in alveolar bone support induced by the Herbst appliance: a tomographic evaluation

    OpenAIRE

    Schwartz, João Paulo; Raveli, Taisa Boamorte; Schwartz-Filho, Humberto Osvaldo; Raveli, Dirceu Barnabé

    2016-01-01

    ABSTRACT Objective: This study evaluated alveolar bone loss around mandibular incisors, induced by the Herbst appliance. Methods: The sample consisted of 23 patients (11 men, 12 women; mean age of 15.76 ± 1.75 years), Class II, Division 1 malocclusion, treated with the Herbst appliance. CBCT scans were obtained before treatment (T0) and after Herbst treatment (T1). Vertical alveolar bone level and alveolar bone thickness of mandibular incisors were assessed. Buccal (B), lingual (L) and to...

  12. Esthetic perception and economic value of orthodontic appliances by lay Brazilian adults

    OpenAIRE

    Feu, Daniela; Catharino, Fernanda; Duplat, Candice Belchior; Capelli Junior, Jonas

    2012-01-01

    OBJECTIVE: To evaluate the esthetic perception of different appliances by Brazilian lay adults and its influence in the attributed value of orthodontic treatment, considering evaluators' socioeconomic status, age and gender. METHODS: Eight different combinations of orthodontic appliances and clear tray aligners were placed in a consenting adult with pleasing smile. Standardized frontal photographs were captured and incorporated into a research album. A sample of adults (n = 252, median = 26 y...

  13. Clinical Effectiveness of Using Aesthetic Fixed Prosthetic Appliances with Combined Occlusal Surface

    Directory of Open Access Journals (Sweden)

    Andrii Biben

    2017-06-01

    Conclusions. Aesthetic fixed prosthetic appliances with combined occlusal surface demonstrated high functional and aesthetic characteristics. The use of the USHPS system showed a decisive advantage of milled frameworks and combined occlusal surface over traditional cast ceramic frameworks.The combination of high mechanical, strength and tribological properties of zirconium dioxide and high biological as well as aesthetic properties of ceramic materials helped reveal high clinical characteristics of aesthetic appliances with combined occlusal surface.

  14. A prospective cohort study of a clip-on fixed functional appliance

    OpenAIRE

    Read, Michael J F; Deacon, Scott; O'Brien, Kevin

    2004-01-01

    The aim of this study was to evaluate the effectiveness of a fixed Twin-block appliance by using a study with a prospective cohort design. Thirty-two children were included in the study over a 2-year period. Cephalometric data were analyzed with the Pancherz cephalometric analysis. Study models were analyzed with the PAR index, and the treatment processes were recorded from the patients' records. The results showed that this appliance was effective in correcting Class II malocclusion; the non...

  15. Evaluation of advanced technologies for residential appliances and residential and commercial lighting

    Energy Technology Data Exchange (ETDEWEB)

    Turiel, I.; Atkinson, B.; Boghosian, S.; Chan, P.; Jennings, J.; Lutz, J.; McMahon, J.; Rosenquist, G.

    1995-01-01

    Section 127 of the Energy Policy Act requires that the Department of Energy (DOE) prepare a report to Congress on the potential for the development and commercialization of appliances that substantially exceed the present federal or state efficiency standards. Candidate high-efficiency appliances must meet several criteria including: the potential exists for substantial improvement (beyond the minimum established in law) of the appliance`s energy efficiency; electric, water, or gas utilities are prepared to support and promote the commercialization of such appliances; manufacturers are unlikely to undertake development and commercialization of such appliances on their own, or development and production would be substantially accelerated by support to manufacturers. This report describes options to improve the efficiency of residential appliances, including water heaters, clothes washers and dryers, refrigerator/freezers, dishwashers, space heating and cooling devices, as well as residential and commercial lighting products. Data from this report (particularly Appendix 1)were used to prepare the report to Congress mentioned previously. For the residential sector, national energy savings are calculated using the LBL Residential Energy Model. This model projects the number of households and appliance saturations over time. First, end-use consumption is calculated for a base case where models that only meet the standard replace existing models as these reach the end of their lifetime. Second, models with efficiencies equal to the technology under consideration replace existing models that reach the end of their lifetime. For the commercial sector, the COMMEND model was utilized to project national energy savings from new technologies. In this report, energy savings are shown for the period 1988 to 2015.

  16. Appliances and their impact: the ownership of domestic technology and time spent on household work.

    Science.gov (United States)

    Bittman, Michael; Rice, James Mahmud; Wajcman, Judy

    2004-09-01

    Ever since the appearance of Vanek's pioneering article in 1974, there has been a controversy about whether 'labour saving' domestic appliances actually save labour time. Vanek argued that time spent in housework had barely changed since 1926, despite the diffusion of practically every known domestic appliance over this period. Gershuny and Robinson challenge Vanek's 'constancy of housework' thesis, arguing that, between 1965 and 1985, domestic technology has significantly reduced the weekly hours of women's routine housework. Although there is much talking past each other, none of the protagonists in this dispute have any direct data about which households own or do not own domestic appliances. Instead, they all rely on the passage of the years as a proxy for ownership of domestic appliances, since a higher proportion of contemporary households now own domestic appliances. The Australian 1997 Time Use Survey (Australian Bureau of Statistics 1998b) is rare among official surveys, as it simultaneously provides detailed information on time spent in housework and an inventory of household appliances. The analysis of this data show that domestic technology rarely reduces women's unpaid working time and even, paradoxically, produces some increases in domestic labour. The domestic division of labour by gender remains remarkably resistant to technological innovation.

  17. Effect of fixed orthodontic appliances on salivary microbial parameters at 6 months: a controlled observational study

    Directory of Open Access Journals (Sweden)

    Delphine MARET

    2014-01-01

    Full Text Available Objective: The aim of this study was to assess the microbial changes in children with fixed orthodontic appliances compared with a control group of children without orthodontic treatment. Material and Methods: Ninety-five children, aged between 12 and 16 years, participated in this study. Forty-eight subjects were fitted with fixed orthodontic appliances and forty-seven were free of any such appliances. The follow-up was 6 months for all children. The association between orthodontic appliances and high levels of Streptococcus mutans and Lactobacillus spp was assessed with logistic regression models, taking age, sex, pH and buffer capacity into account. Results: Differences at baseline between the two groups were not statistically significant. We found that wearing a fixed orthodontic appliance was associated with high levels of Streptococcus mutans and Lactobacillus spp (adjusted OR: 6.65, 95% CI [1.98-22.37]; 9.49, 95% CI [2.57-35.07], respectively, independently of other variables. Conclusion: The originality of the present epidemiological study was to evaluate the evolution of salivary microbial parameters in a population of children with fixed orthodontic appliances. Our results show an increase of Streptococcus mutans and Lactobacillus spp values during the follow-up. The whole dental workforce should be aware that preventive measures are of paramount importance during orthodontic treatment.

  18. Comparison of External Apical Root Resorption after Orthodontic Treatment with Two Appliances (Standard Edgewise and MBT

    Directory of Open Access Journals (Sweden)

    V. Mollabashi

    2016-01-01

    Full Text Available Introduction & Objective: The aim of this study was todeterminetheamount of external apical root resorption(EARRwithin two orthodontic appliances (standard edgewise and MBT. Material & Methods In this retrospective study, panoramic radiographs of 83 orthodontic patients (27 male and 56 female were evaluated. 46 patients had been treated with standard edgewise appliance (29 patients with extraction and 17 patients without extraction and 37 patients had been treated with MBT appliance (27 patients with extraction and 10 patients without extraction.EARR were evaluated in 24 teeth (anterior teeth, premolars and first molars in each patient. SPSS software and ordinal regression test were used for statistical analysis. Result: In this study the most EARR was seen in upper lateral incisors, then lower lateral incisors.EARR in upper canines and lower second premolars was significantly related to extraction of first premolarin MBT appliance. In non extraction cases, EARR was not related to the orthodontic appliance. Conclusion: Incisors teeth are the most disposed teeth to EARR. Orthodontic treatment with extraction increased EARR in canines and second premolars. MBT appliance may increase EARR. Sci J Hamadan Univ Med Sci . 2016; 22 (4 :316-322

  19. Alteration in Taste Perception among Young Children during the use of Removable Orthodontic Appliance Therapy.

    Science.gov (United States)

    Razdan, Priyanka; Sakthivel, V S; Naqvi, Zuber A; Goyal, Vinod; Tripathi, Swati; Singh, Smita

    2017-07-01

    The sense of smell is very influential in the taste of foods. If the smell pleases us, we anticipate the taste of the food with a great deal of relish. If our sense of smell is impaired, so is our taste. The effect of appliance on taste perceptions has always had a controversial subject. The present study was designed to analyze the change in taste perception in children using removable orthodontic appliances. All the selected volunteers were given different taste stimuli and were asked to score as per their perception. The verbal score was calculated based on the correct and incorrect taste stimuli given to them. Visual analog scale was used to assess intensity and hedonic (palatability) estimation of the volunteers. The volunteers from both study and control groups scored different values for taste stimuli. The majority of stimuli were estimated correctly by both groups. There was no statistically significant difference between the study and control groups. In different testing sessions, the scoring of the volunteers was nearly constant, indicating that an appliance does not play a major role in the alteration of taste stimuli. The appliance brings about transient change in taste perception, we should educate the patient before delivering the appliance about the transient change in taste perception and encourage full-time wear of the appliance, including during meals, without fear of affecting taste sensations.

  20. A randomized clinical trial comparing mandibular incisor proclination produced by fixed labial appliances and clear aligners.

    Science.gov (United States)

    Hennessy, Joe; Garvey, Thérèse; Al-Awadhi, Ebrahim A

    2016-09-01

    To compare the mandibular incisor proclination produced by fixed labial appliances and third generation clear aligners. Patients underwent a course of orthodontic treatment using either fixed labial appliances or clear aligners (Invisalign). Mandibular incisor proclination was measured by comparing pretreatment and near-end treatment lateral cephalograms. Eligibility criteria included adult patients with mild mandibular incisor crowding (clear aligner group. Baseline characteristics were similar for both groups: Fixed appliance mean crowding was 2.1 ± 1.3 mm vs clear aligner mean crowding, 2.5 ± 1.3 mm; pretreatment mean mandibular incisor inclination for the fixed appliance group was 90.8 ± 5.4° vs 91.6 ± 6.4° for the clear aligner group. Fixed appliances produced 5.3 ± 4.3° of mandibular incisor proclination. Clear aligners proclined the mandibular incisors by 3.4 ± 3.2°. The difference between the two groups was not statistically significant (P > .05). There was no difference in the amount of mandibular incisor proclination produced by clear aligners and fixed labial appliances in mild crowding cases.

  1. Soft tissue profile changes after Functional Mandibular Advancer or Herbst appliance treatment in class II patients.

    Science.gov (United States)

    Hourfar, Jan; Lisson, Jörg Alexander; Gross, Ulrich; Frye, Linda; Kinzinger, Gero Stefan Michael

    2018-03-01

    The objective of the present study is to compare the effects on soft tissue profile in class II patients after treatment with either "Functional Mandibular Advancer" (FMA) or Herbst appliance. The study included n = 42 patients treated with either FMA (n = 21) or Herbst appliance (n = 21) by the same experienced orthodontist. The treatment followed a single-step advancement protocol. Lateral cephalograms were analyzed through a set of customized measurements. The actual therapeutic effect was calculated using data from a growth survey. After testing for normal distribution and homogeneity of variance, data were analyzed by one-sample Student's t tests and independent Student's t tests. Statistical significance was set at p profile were found in FMA and Herbst appliance patients. All remaining variables revealed no significant differences. Treatment-related changes on the facial soft tissue profile could be regarded similar in class II patients treated with FMA or Herbst appliance. No treatment-related changes that were specific for FMA or Herbst appliance could be identified. Only moderate changes were noted comparing pre- and posttreatment soft tissue profiles. Despite proven differences in skeletal and dental treatment effects, the facial profile has not to be taken into consideration when choosing between FMA and Herbst appliance for class II treatment.

  2. The impact of orthodontic appliances on eating - young people's views and experiences.

    Science.gov (United States)

    Carter, Louise A; Geldenhuys, Mieke; Moynihan, Paula J; Slater, Dina R; Exley, Catherine E; Rolland, Sarah L

    2015-06-01

    Orthodontic appliances are known to cause patients difficulty with eating. Learning more about the issues patients face, while eating with orthodontic appliances in place, will allow us to create more informative and relevant patient information, thereby improving patient compliance and treatment success. This study aims to understand how orthodontic appliances impact on eating in the broader context and to explore adolescent patients' perceptions of eating with orthodontic appliances. Purposive sampling was used and 19 participants currently undergoing orthodontic treatment and aged 11-14 years were selected for either a focus group or semi-structured interview to explore eating-related issues. Data collection and analysis were carried out as an iterative process broadly following principles of thematic analysis. Data collection ceased when no new themes emerged. Two main themes relating to eating problems emerged: restriction of food choice and problems associated with the eating process. Participants reported restricting food choice due to physical aspects of the appliance, advice given by their orthodontist, fear of breakage and also to minimize embarrassment. Participants also reported problems with the time taken to eat, chewing problems, taste change and being messy while eating. Additionally, time in treatment, the location of eating and relationship with those present during eating influenced emotions. Some participants indicated a positive impact of orthodontic appliances on their diet. These results can be used to further inform dietary advice offered to patients. Factors were identified which may not be considered in clinical practice but which could improve the value of dietary advice given to patients.

  3. Comparative evaluation of sagittal anchorage loss in lingual and labial appliances during space closure: A pilot study

    Directory of Open Access Journals (Sweden)

    Shivanand Venkatesh

    2015-01-01

    Full Text Available Aim: The purpose of this investigation was to assess and compare the anchorage loss between labial and lingual appliance systems during space closure. Materials and Methods: Twenty subjects were part of the study among which 10 subjects (mean age 21 ± 3.6 years were treated using lingual appliance system (0.018" slot-STb™ and 10 subjects (mean age 19 ± 6.1 years were treated using labial preadjusted edgewise appliance system (0.018" slot-MBT™ . First premolar extractions were performed to enable retraction of anterior teeth. Lateral cephalometric radiographs were taken at two intervals, before starting space closure and after space closure that were connoted as T0 and T1 and were analyzed using the method described by Pancherz to measure anchorage loss. Intraclass correlation coefficient (ICC was used to evaluate intraexaminer reliability of the measurements. Student′s t-test was performed to verify any statistical significant correlation between the labial and lingual appliance systems. Statistical differences were determined at the 95% confidence level (P < 0.05. Results: The results showed that all ICC for lingual and labial group were ≥0.90 showing good repeatability of the measurements. Mean anchorage loss of 1.238 ± 0.17 mm in lingual appliance system and an anchorage loss of 2.06 ± 0.39 mm occurred with the labial appliance system. On the comparison between the two appliance systems, lingual appliance demonstrated a significantly lesser anchorage loss than did the labial appliance. Interpretation and Conclusion: This prospective study concludes with the fact that lingual appliance provided better anchorage control than labial appliance during space closure. Use of lingual appliance could be considered in critical anchorage cases when compared with labial appliance.

  4. Development of superconducting wire and cable for the SSC project in Sumitomo Electric Industries

    International Nuclear Information System (INIS)

    Sashida, T.; Saito, S.; Oku, G.; Kurimoto, K.; Yamada, Y.; Yokota, M.; Ohmatsu, K.; Nagata, M.

    1991-01-01

    As a large production volume of NbTi superconducting wire and cable is required for the SSC project, a production process has been developed at Sumitomo Electric to optimize critical variables of wire properties. To achieve high electrical properties and a high overall yield of NbTi alloy in the fabrication process, the authors have employed carefully designed large size multifilament billets weighing more than 350kg to decrease the number of billets in large production scale. The collider dipole magnet consists of inner and outer cables, and the cable should be as uniform as possible to ensure the performance of the magnets. The authors studied two aspects to obtain such uniformity of superconducting wire; one is the selection of unit weight and the other is the property of critical current density of a strand

  5. 47 CFR 76.802 - Disposition of cable home wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of cable home wiring. 76.802... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... cable operator shall not remove the cable home wiring unless it gives the subscriber the opportunity to...

  6. Automatic reel controls filler wire in welding machines

    Science.gov (United States)

    Millett, A. V.

    1966-01-01

    Automatic reel on automatic welding equipment takes up slack in the reel-fed filler wire when welding operation is terminated. The reel maintains constant, adjustable tension on the wire during the welding operation and rewinds the wire from the wire feed unit when the welding is completed.

  7. 47 CFR 32.2321 - Customer premises wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Customer premises wiring. 32.2321 Section 32... Customer premises wiring. (a) This account shall include all amounts transferred from the former Account 232, Station Connections, inside wiring subclass. (b) Embedded Customer Premises Wiring is that...

  8. 30 CFR 77.701-3 - Grounding wires; capacity.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity. 77.701-3 Section 77... MINES Grounding § 77.701-3 Grounding wires; capacity. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames, casings, and other metallic enclosures, such grounding wires will be...

  9. Wire Bonder: Kulicke and Soffa Model 4526

    Data.gov (United States)

    Federal Laboratory Consortium — Description:CORAL Name: Wire BonderNeeds Description.Scientific Opportunities / Applications:Wedge bonderSemi-automatic and manual modesIndependent Z-axis control,...

  10. Beam Profiling through Wire Chambing Tracking

    CERN Document Server

    Nash, W

    2013-01-01

    This note describes the calibration of the Delay Wire Chambers (DWCs) used during test runs of CALICE’s Tungsten Digital Hadron Calorimeter (W-DHCAL) prototype in CERN’s SPS beam line (10 – 300 GeV).

  11. Copyright and Wire Broadcasting Under Belgian Law

    Science.gov (United States)

    Namurois, Albert

    1975-01-01

    A discussion of a case whereby substantial damages, if not criminal proceedings, will sanction, according to circumstances, both television organizations and those who in certain conditions distribute their programs by wire or communicate them to the public. (Author/HB)

  12. Josephson junction arrays and superconducting wire networks

    International Nuclear Information System (INIS)

    Lobb, C.J.

    1992-01-01

    Techniques used to fabricate integrated circuits make it possible to construct superconducting networks containing as many as 10 6 wires or Josephson junctions. Such networks undergo phase transitions from resistive high-temperature states to ordered low-resistance low-temperature states. The nature of the phase transition depends strongly on controllable parameters such as the strength of the superconductivity in each wire or junction and the external magnetic field. This paper will review the physics of these phase transitions, starting with the simplest zero-magnetic field case. This leads to a Kosterlitz-Thouless transition when the junctions or wires are weak, and a simple mean-field fransition when the junctions or wires are strong. Rich behavior, resulting from frustration, occurs in the presence of a magnetic field. (orig.)

  13. Highly stretchable wrinkled gold thin film wires.

    Science.gov (United States)

    Kim, Joshua; Park, Sun-Jun; Nguyen, Thao; Chu, Michael; Pegan, Jonathan D; Khine, Michelle

    2016-02-08

    With the growing prominence of wearable electronic technology, there is a need to improve the mechanical reliability of electronics for more demanding applications. Conductive wires represent a vital component present in all electronics. Unlike traditional planar and rigid electronics, these new wearable electrical components must conform to curvilinear surfaces, stretch with the body, and remain unobtrusive and low profile. In this paper, the piezoresistive response of shrink induced wrinkled gold thin films under strain demonstrates robust conductive performance in excess of 200% strain. Importantly, the wrinkled metallic thin films displayed negligible change in resistance of up to 100% strain. The wrinkled metallic wires exhibited consistent performance after repetitive strain. Importantly, these wrinkled thin films are inexpensive to fabricate and are compatible with roll to roll manufacturing processes. We propose that these wrinkled metal thin film wires are an attractive alternative to conventional wires for wearable applications.

  14. Tensosensitivity of the Hot-Wire Probe

    National Research Council Canada - National Science Library

    Pak, A

    2002-01-01

    ...., on the anemometer type. In a constant current anemometer, it is possible to measure and separate out the noise moving to the electric circuit of the anemometer, it is not the case with hot-wire anemometers of other types...

  15. Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires.

    Science.gov (United States)

    Tada, Yoshifumi; Hayakawa, Tohru; Nakamura, Yoshiki

    2017-08-09

    Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 × 0.022 in² and 0.019 × 0.025 in² (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bending properties were evaluated in a modified three-point bending system for orthodontics. The static friction between the orthodontic wire and the bracket was also measured. The load-deflection curves were similar among Ni-Ti and PEEK wires, except for 16PEEK with slot-lid ligation. The bending force of 19-25PEEK wire was comparable with that of Ni-Ti wire. 19-25PEEK showed the highest load at the deflection of 1500 μm ( p 0.05). No significant difference was seen in static friction between all three PEEK wires and Ni-Ti wire ( p > 0.05). It is suggested that 19-25PEEK will be applicable for orthodontic treatment with the use of slot-lid ligation.

  16. Audio wiring guide how to wire the most popular audio and video connectors

    CERN Document Server

    Hechtman, John

    2012-01-01

    Whether you're a pro or an amateur, a musician or into multimedia, you can't afford to guess about audio wiring. The Audio Wiring Guide is a comprehensive, easy-to-use guide that explains exactly what you need to know. No matter the size of your wiring project or installation, this handy tool provides you with the essential information you need and the techniques to use it. Using The Audio Wiring Guide is like having an expert at your side. By following the clear, step-by-step directions, you can do professional-level work at a fraction of the cost.

  17. A new approach to household appliance energy test procedures

    Energy Technology Data Exchange (ETDEWEB)

    Ernebrant, S.; Wihlborg, M.

    1999-03-01

    Energy test procedures provides the industry with a method to measure its products energy consumption. The energy test procedures are the technical foundation to every energy standard and labelling system. Depending on which country the product is going to be sold in, the manufacturers must follow different standards. This report concentrates on appliance test procedures, with the main focus on refrigerators. Recently, a new technology -microcontrollers- is undermining the credibility of the test procedures. New features, saving energy in real-life, are not picked up by the test procedures. It is estimated that as much as 30% of energy could be saved with this technology. Microcontrollers have also led to the possibility to circumvent tests. A new model is presented in the report, which handles these energy savings and make it harder cheating on tests. The model divides the test procedure in two parts; hardware tests and software tests, and uses a Matlab/Simulink computer model to calculate the energy consumption. Examples of hardware- and software test methods for refrigerators are described. A refrigerator is used as an example to present the model. The possibility to harmonize the energy standards to one global standard, which could mean substantial savings and make international trade more efficient, is also discussed 24 refs, 30 figs. Examination paper

  18. Oral appliance treatment for obstructive sleep apnea: an update.

    Science.gov (United States)

    Sutherland, Kate; Vanderveken, Olivier M; Tsuda, Hiroko; Marklund, Marie; Gagnadoux, Frederic; Kushida, Clete A; Cistulli, Peter A

    2014-02-15

    Oral appliances (OA) have emerged as an alternative to continuous positive airway pressure (CPAP) for obstructive sleep apnea (OSA) treatment. The most commonly used OA reduces upper airway collapse by advancing the mandible (OAm). There is a strong evidence base demonstrating OAm improve OSA in the majority of patients, including some with more severe disease. However OAm are not efficacious for all, with approximately one-third of patients experiencing no therapeutic benefit. OAm are generally well tolerated, although short-term adverse effects during acclimatization are common. Long-term dental changes do occur, but these are for the most part subclinical and do not preclude continued use. Patients often prefer OAm to gold-standard CPAP treatment. Head-to-head trials confirm CPAP is superior in reducing OSA parameters on polysomnography; however, this greater efficacy does not necessarily translate into better health outcomes in clinical practice. Comparable effectiveness of OAm and CPAP has been attributed to higher reported nightly use of OAm, suggesting that inferiority in reducing apneic events may be counteracted by greater treatment adherence. Recently, significant advances in commercially available OAm technologies have been made. Remotely controlled mandibular positioners have the potential to identify treatment responders and the level of therapeutic advancement required in single night titration polysomnography. Objective monitoring of OAm adherence using small embedded temperature sensing data loggers is now available and will enhance clinical practice and research. These technologies will further enhance efficacy and effectiveness of OAm treatment for OSA.

  19. The Effectiveness and Clinical Usability of a Handheld Information Appliance

    Directory of Open Access Journals (Sweden)

    Patricia A. Abbott

    2012-01-01

    Full Text Available Clinical environments are complex, stressful, and safety critical—heightening the demand for technological solutions that will help clinicians manage health information efficiently and safely. The industry has responded by creating numerous, increasingly compact and powerful health IT devices that fit in a pocket, hook to a belt, attach to eyeglasses, or wheel around on a cart. Untethering a provider from a physical “place” with compact, mobile technology while delivering the right information at the right time and at the right location are generally welcomed in clinical environments. These developments however, must be looked at ecumenically. The cognitive load of clinicians who are occupied with managing or operating several different devices during the process of a patient encounter is increased, and we know from decades of research that cognitive overload frequently leads to error. “Technology crowding,” enhanced by the plethora of mobile health IT, can actually become an additional millstone for busy clinicians. This study was designed to gain a deeper understanding of clinicians’ interactions with a mobile clinical computing appliance (Motion Computing C5 designed to consolidate numerous technological functions into an all-in-one device. Features of usability and comparisons to current methods of documentation and task performance were undertaken and results are described.

  20. Note: Improved wire-wound heater.

    Science.gov (United States)

    Steinmann, Ricardo G; Vitoux, Hugo

    2015-01-01

    The authors have measured, at cryogenic temperature, the upper limit of the heat transfer in different configurations of a wire-wound heater. We found that the heat transferred has an upper limit of about 15 W/cm(2) and is dependent on the diameter of the wire. In this paper, we present three ways of increasing the heat transferred by this type of heater and its application in different continuous flow cryostats.