WorldWideScience

Sample records for wire electronic resource

  1. Electron transport in stretched monoatomic gold wires.

    Science.gov (United States)

    Grigoriev, A; Skorodumova, N V; Simak, S I; Wendin, G; Johansson, B; Ahuja, R

    2006-12-08

    The conductance of monoatomic gold wires containing 3-7 gold atoms has been obtained from ab initio calculations. The transmission is found to vary significantly depending on the wire stretching and the number of incorporated atoms. Such oscillations are determined by the electronic structure of the one-dimensional (1D) part of the wire between the contacts. Our results indicate that the conductivity of 1D wires can be suppressed without breaking the contact.

  2. Radiation of relativistic electrons in a periodic wire structure

    Energy Technology Data Exchange (ETDEWEB)

    Soboleva, V.V., E-mail: sobolevaveronica@mail.ru; Naumenko, G.A.; Bleko, V.V.

    2015-07-15

    We present in this work the experimental investigation of the interaction of relativistic electron field with periodic wire structures. We used two types of the targets in experiments: flat wire target and sandwich wire target that represent the right triangular prism. The measurements were done in millimeter wavelength region (10–40 mm) on the relativistic electron beam with energy of 6.2 MeV in far-field zone. We showed that bunched electron beam passing near wire metamaterial prism generates coherent Cherenkov radiation. The experiments with flat wire target were carried out in two geometries. In the first geometry the electron beam passed close to the flat wire target surface. In the second case the electron beam passed through the flat wire structure with generation of a coherent backward transition radiation (CBTR). The comparison of the Cherenkov radiation intensity and BTR intensity from the flat wire target and from the flat conductive target (conventional BTR) was made.

  3. Filler-wire positioner for electron beam welding

    Science.gov (United States)

    Beaupre, W. M.; Fueg, L. B.; Phillips, J. A.

    1970-01-01

    Miniaturized positioner is installed in any electron beam vacuum chamber for use with wire feed applications requiring filler wire. Horizontal and vertical control of the positioner is maintained from a console while chamber is under vacuum. Device permits more positive positioning of welding filler wire.

  4. Electronic transport in Si:P δ-doped wires

    DEFF Research Database (Denmark)

    Smith, J. S.; Drumm, D. W.; Budi, Akin

    2015-01-01

    Despite the importance of Si:P δ-doped wires for modern nanoelectronics, there are currently no computational models of electron transport in these devices. In this paper we present a nonequilibrium Green’s function model for electronic transport in a δ-doped wire, which is described by a tight...

  5. Bound Electron States in Skew-symmetric Quantum Wire Intersections

    Science.gov (United States)

    2014-01-01

    for electronic transport studies was to confine resonant- tunneling heterostructures laterally with a fabrication-imposed po- tential. This approach...Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 Quantum Wires, Crossed Nanowires , Trapped Electron States, Quantum Dots REPORT...realistic systems such as semiconductor nanowire films and carbon nanotube bundles. Bound electron states in skew-symmetric quantum wire intersections by

  6. Distance Dependence of the Electronic Contact of a Molecular Wire

    Science.gov (United States)

    Grill, L.; Moresco, F.; Jiang, P.; Stojkovic, S.; Gourdon, A.; Joachim, C.; Rieder, K.-H.

    2005-09-01

    The central molecular wire of a so-called Reactive Lander molecule is brought in electronic contact with an atomic scale metallic nanostructure by manipulation with the STM tip. Several stable conformations are obtained in a controlled way, in accordance with calculations. An additional contribution to the tunneling current is observed at the end of the molecular board, reflecting the electronic interaction between the molecular wire and the nanostructure. The characteristic intensity of this electronic contact for different conformations is discussed by means of the vertical interatomic distance between the molecular wire and the metal atoms.

  7. Electronic Properties of Quantum Wire Networks

    OpenAIRE

    Kuzmenko, Igor

    2005-01-01

    Quantum wire networks (``quantum crossbars'', QCB) represent a 2D grid formed by superimposed crossing arrays of parallel conducting quantum wires, molecular chains or metallic single-wall carbon nanotubes. QCB coupled only by capacitive interaction in the crosses have similar low-energy, long-wave properties characterized as a crossed sliding Luttinger liquid (CSLL) phase. In this Thesis we develop a theory of interacting Bose excitations (plasmons) in QCB. We analyze spectrum of boson field...

  8. ELECTRONIC HUMAN RESOURCE MANAGEMENT

    OpenAIRE

    Dr. M. Panneerselvam

    2017-01-01

    Electronic Human Resource Management is an essence the revolution of human resource functions to management and employees. These functions are typically used via intranet and web technology. This helps the organization to improve their standards where they can able to review and forward. All those documents can be viewed within a fraction of second with help of client and server links. The phenomenon of E- HRM deserves closer and more fundamental roots to HR activity. The E-HRM develops and b...

  9. Design and experimental tests of free electron laser wire scanners

    Directory of Open Access Journals (Sweden)

    G. L. Orlandi

    2016-09-01

    Full Text Available SwissFEL is a x-rays free electron laser (FEL driven by a 5.8 GeV linac under construction at Paul Scherrer Institut. In SwissFEL, wire scanners (WSCs will be complementary to view-screens for emittance measurements and routinely used to monitor the transverse profile of the electron beam during FEL operations. The SwissFEL WSC is composed of an in-vacuum beam-probe—motorized by a stepper motor—and an out-vacuum pick-up of the wire signal. The mechanical stability of the WSC in-vacuum hardware has been characterized on a test bench. In particular, the motor induced vibrations of the wire have been measured and mapped for different motor speeds. Electron-beam tests of the entire WSC setup together with different wire materials have been carried out at the 250 MeV SwissFEL Injector Test Facility (SITF, Paul Scherrer Institut, CH and at FERMI (Elettra-Sincrotrone Trieste, Italy. In particular, a comparative study of the relative measurement accuracy and the radiation-dose release of Al(99∶Si(1 and tungsten (W wires has been carried out. On the basis of the outcome of the bench and electron-beam tests, the SwissFEL WSC can be qualified as a high resolution and machine-saving diagnostic tool in consideration of the mechanical stability of the scanning wire at the micrometer level and the choice of the wire material ensuring a drastic reduction of the radiation-dose release with respect to conventional metallic wires. The main aspects of the design, laboratory characterization and electron beam tests of the SwissFEL WSCs are presented.

  10. Design and experimental tests of free electron laser wire scanners

    Science.gov (United States)

    Orlandi, G. L.; Heimgartner, P.; Ischebeck, R.; Loch, C. Ozkan; Trovati, S.; Valitutti, P.; Schlott, V.; Ferianis, M.; Penco, G.

    2016-09-01

    SwissFEL is a x-rays free electron laser (FEL) driven by a 5.8 GeV linac under construction at Paul Scherrer Institut. In SwissFEL, wire scanners (WSCs) will be complementary to view-screens for emittance measurements and routinely used to monitor the transverse profile of the electron beam during FEL operations. The SwissFEL WSC is composed of an in-vacuum beam-probe—motorized by a stepper motor—and an out-vacuum pick-up of the wire signal. The mechanical stability of the WSC in-vacuum hardware has been characterized on a test bench. In particular, the motor induced vibrations of the wire have been measured and mapped for different motor speeds. Electron-beam tests of the entire WSC setup together with different wire materials have been carried out at the 250 MeV SwissFEL Injector Test Facility (SITF, Paul Scherrer Institut, CH) and at FERMI (Elettra-Sincrotrone Trieste, Italy). In particular, a comparative study of the relative measurement accuracy and the radiation-dose release of Al (99 )∶Si (1 ) and tungsten (W) wires has been carried out. On the basis of the outcome of the bench and electron-beam tests, the SwissFEL WSC can be qualified as a high resolution and machine-saving diagnostic tool in consideration of the mechanical stability of the scanning wire at the micrometer level and the choice of the wire material ensuring a drastic reduction of the radiation-dose release with respect to conventional metallic wires. The main aspects of the design, laboratory characterization and electron beam tests of the SwissFEL WSCs are presented.

  11. Educating for Electronic Resources

    Science.gov (United States)

    Grogg, Jill E.

    2008-01-01

    While mission statements for various libraries and information centers necessarily vary, all librarians face "two very pressing charges: make voluminous numbers of electronic resources as visible as possible in a landscape of multiple access points and simultaneously manage all the technology, tasks, and data necessary to facilitate such…

  12. Electronic Resource Management Systems

    Directory of Open Access Journals (Sweden)

    Mark Ellingsen

    2004-10-01

    Full Text Available Computer applications which deal with electronic resource management (ERM are quite a recent development. They have grown out of the need to manage the burgeoning number of electronic resources particularly electronic journals. Typically, in the early years of e-journal acquisition, library staff provided an easy means of accessing these journals by providing an alphabetical list on a web page. Some went as far as categorising the e-journals by subject and then grouping the journals either on a single web page or by using multiple pages. It didn't take long before it was recognised that it would be more efficient to dynamically generate the pages from a database rather than to continually edit the pages manually. Of course, once the descriptive metadata for an electronic journal was held within a database the next logical step was to provide administrative forms whereby that metadata could be manipulated. This in turn led to demands for incorporating more information and more functionality into the developing application.

  13. Electron energy spectrum in core-shell elliptic quantum wire

    Directory of Open Access Journals (Sweden)

    V.Holovatsky

    2007-01-01

    Full Text Available The electron energy spectrum in core-shell elliptic quantum wire and elliptic semiconductor nanotubes are investigated within the effective mass approximation. The solution of Schrodinger equation based on the Mathieu functions is obtained in elliptic coordinates. The dependencies of the electron size quantization spectrum on the size and shape of the core-shell nanowire and nanotube are calculated. It is shown that the ellipticity of a quantum wire leads to break of degeneration of quasiparticle energy spectrum. The dependences of the energy of odd and even electron states on the ratio between semiaxes are of a nonmonotonous character. The anticrosing effects are observed at the dependencies of electron energy spectrum on the transversal size of the core-shell nanowire.

  14. Electron transport through monovalent atomic wires

    DEFF Research Database (Denmark)

    Lee, Y. J.; Brandbyge, Mads; Puska, M. J.

    2004-01-01

    Using a first-principles density-functional method we model electron transport through linear chains of monovalent atoms between two bulk electrodes. For noble-metal chains the transport resembles that for free electrons over a potential barrier whereas for alkali-metal chains resonance states...... at the chain determine the conductance. As a result, the conductance for noble-metal chains is close to one quantum of conductance, and it oscillates moderately so that an even number of chain atoms yields a higher value than an odd number. The conductance oscillations are large for alkali-metal chains...

  15. Development of high voltage lead wires using electron beam irradiation

    Science.gov (United States)

    Hun-Jai, Bae; Ho-Soung, Sohn; Dong-Jung, Choi

    1995-09-01

    It is known to those skilled to the art that the electric wires used in high voltage operating electric equipments such as TV sets, microwave ovens, duplicators and etc., have such a structure that a conductor is coated with an insulating layer which is encapsulated with a protecting jacket layer. The electric wire specification such as UL and CSA requires superior cut-through property and flame-retardant property of the wire for utilization safety. The cut-through property of insulation material, for example, high density polyethylene, can be increased by crosslinking of the polymer. Also the flame-retardant property of jacket material which protects the flammable inner insulation can be raised by flame-retardant formulating of the material. In the wire and cable industry, crosslinking by electron beam processing is more effective than that by chemical processing in the viewpoint of through-put rate of the products. The jacket layer of the wire plays the role of protecting the insulation material from burning. The protecting ability of the jacket is related to its inherent flammability and formability of swollen carbonated layer when burned. Crosslinking of the material gives a good formability of swollen carbonated layer, and it protects the insulation material from direct flame. In formulating the flame-retardant jacket material, a crosslinking system must be considered with base polymers and other flame-retardant additives.

  16. Electronic commerce: wiring the coal industry for new data technology

    Energy Technology Data Exchange (ETDEWEB)

    Carter, R.A.

    1998-07-01

    Industry pundits predict that coal by wire may some day replace much of the industry`s long-distance shipping requirements and their attendant costs, but data by wire, also known as electronic commerce (EC) can today offer coal producers and customers the means to gather and send large volumes of data cheaply and quickly. EC`s major components - electronic data interchange (EDI), bar-coding, smart codes, radio frequency `D`, and the internet - can reduce costs in equipment-intensive industries such as mining. The US National Mining Association sponsored a forum to discuss these alternatives at its 1998 Electronic Commerce Summit held in Tuscon, Arizona, 18-20 May. A report is given of discussions at the forum and contacts are given for sources of EDI information.

  17. Electronic Resource Management and Design

    Science.gov (United States)

    Abrams, Kimberly R.

    2015-01-01

    We have now reached a tipping point at which electronic resources comprise more than half of academic library budgets. Because of the increasing work associated with the ever-increasing number of e-resources, there is a trend to distribute work throughout the library even in the presence of an electronic resources department. In 2013, the author…

  18. Use of beam deflection to control an electron beam wire deposition process

    Science.gov (United States)

    Taminger, Karen M. (Inventor); Hofmeister, William H. (Inventor); Hafley, Robert A. (Inventor)

    2013-01-01

    A method for controlling an electron beam process wherein a wire is melted and deposited on a substrate as a molten pool comprises generating the electron beam with a complex raster pattern, and directing the beam onto an outer surface of the wire to thereby control a location of the wire with respect to the molten pool. Directing the beam selectively heats the outer surface of the wire and maintains the position of the wire with respect to the molten pool. An apparatus for controlling an electron beam process includes a beam gun adapted for generating the electron beam, and a controller adapted for providing the electron beam with a complex raster pattern and for directing the electron beam onto an outer surface of the wire to control a location of the wire with respect to the molten pool.

  19. Parallel power electronics filters in three-phase four-wire systems principle, control and design

    CERN Document Server

    Wong, Man-Chung; Lam, Chi-Seng

    2016-01-01

    This book describes parallel power electronic filters for 3-phase 4-wire systems, focusing on the control, design and system operation. It presents the basics of power-electronics techniques applied in power systems as well as the advanced techniques in controlling, implementing and designing parallel power electronics converters. The power-quality compensation has been achieved using active filters and hybrid filters, and circuit models, control principles and operational practice problems have been verified by principle study, simulation and experimental results. The state-of-the-art research findings were mainly developed by a team at the University of Macau. Offering background information and related novel techniques, this book is a valuable resource for electrical engineers and researchers wanting to work on energy saving using power-quality compensators or renewable energy power electronics systems. .

  20. Fulleropyrrolidine end-capped molecular wires for molecular electronics--synthesis, spectroscopic, electrochemical, and theoretical characterization

    DEFF Research Database (Denmark)

    Sørensen, Jakob Kryger; Fock, Jeppe; Pedersen, Anders Holmen

    2011-01-01

    In continuation of previous studies showing promising metal-molecule contact properties a variety of C(60) end-capped "molecular wires" for molecular electronics were prepared by variants of the Prato 1,3-dipolar cycloaddition reaction. Either benzene or fluorene was chosen as the central wire......-withdrawing ester group present. The effect of extending the p-system of the central wire from 1,4-phenylenediamine to 2,7-fluorenediamine was investigated by absorption, fluorescence, and electrochemical methods. The central wire and the C(60) end-groups were found not to electronically communicate in the ground...... state. However, the fluorescence of C(60) was quenched by charge transfer from the wire to C(60). Quantum chemical calculations predict and explain the collapse of coherent electronic transmission through one of the fulleropyrrolidine-terminated molecular wires....

  1. Electron transport in coupled double quantum wells and wires

    Energy Technology Data Exchange (ETDEWEB)

    Harff, N.E.; Simmons, J.A.; Lyo, S.K. [and others

    1997-04-01

    Due to inter-quantum well tunneling, coupled double quantum wells (DQWs) contain an extra degree of electronic freedom in the growth direction, giving rise to new transport phenomena not found in single electron layers. This report describes work done on coupled DQWs subject to inplane magnetic fields B{sub {parallel}}, and is based on the lead author`s doctoral thesis, successfully defended at Oregon State University on March 4, 1997. First, the conductance of closely coupled DQWs in B{sub {parallel}} is studied. B{sub {parallel}}-induced distortions in the dispersion, the density of states, and the Fermi surface are described both theoretically and experimentally, with particular attention paid to the dispersion anticrossing and resulting partial energy gap. Measurements of giant distortions in the effective mass are found to agree with theoretical calculations. Second, the Landau level spectra of coupled DQWs in tilted magnetic fields is studied. The magnetoresistance oscillations show complex beating as Landau levels from the two Fermi surface components cross the Fermi level. A third set of oscillations resulting from magnetic breakdown is observed. A semiclassical calculation of the Landau level spectra is then performed, and shown to agree exceptionally well with the data. Finally, quantum wires and quantum point contacts formed in DQW structures are investigated. Anticrossings of the one-dimensional DQW dispersion curves are predicted to have interesting transport effects in these devices. Difficulties in sample fabrication have to date prevented experimental verification. However, recently developed techniques to overcome these difficulties are described.

  2. Scattering of H- Stripped Electrons from SEM Grids and Wire Scanners at the CERN LINAC4

    CERN Document Server

    Cheymol, B; Duraffourg, M; Focker, GJ; Roncarolo, F; Raich, U; Hessler, C; Vuitton, C; Zocca, F

    2013-01-01

    At the CERN LINAC4, wire grids and scanners will be used to characterize the H− beam transverse profiles from 45 keV to 160 MeV. The wire signal will be determined by the balance between secondary emission and number of charges stopped in the wire, which will depend on the wire material and diameter, the wire polarization and the beam energy. The outermost electrons of H− ions impinging on a wire are stripped in the first nanometers of material. A portion of such electrons are scattered away from the wire and can reach the neighboring wires. In addition, scattered electrons hitting the surrounding beam pipe generate secondary electrons that can also perturb the measurement. Monte Carlo simulations, analytical calculations and a laboratory experiment allowed quantifying the amount of scattering and the scattered particles distributions. The experiment was based on 70 keV electrons, well reproducing the case of 128 MeV H− ions. For all the LINAC4 simulated cases the predicted effect on the beam size rec...

  3. Structure and electronic properties of molybdenum monatomic wires encapsulated in carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    GarcIa-Fuente, A; Vega, A [Departamento de Fisica Teorica, Atomica y Optica. Universidad de Valladolid, E-47011 Valladolid (Spain); GarcIa-Suarez, V M; Ferrer, J [Departamento de Fisica and CINN, Universidad de Oviedo, 33007 Oviedo (Spain)

    2011-07-06

    Monatomic chains of molybdenum encapsulated in single-walled carbon nanotubes (CNTs) of different chiralities are investigated using density functional theory. We determine the optimal size of the CNT for encapsulating a single atomic wire, as well as the most stable atomic arrangement adopted by the wire. We also study the transport properties in the ballistic regime by computing the transmission coefficients and tracing them back to the electronic conduction channels of the wire and the host. We predict that CNTs of appropriate radii encapsulating a Mo wire have metallic behavior, even if both the nanotube and the wire are insulators. Therefore, encapsulation of Mo wires in CNTs is a way to create conductive quasi-one-dimensional hybrid nanostructures.

  4. A Wire Scanner Design for Electron Beam Profile Measurement in the Linac Coherent Light Source Undulator

    CERN Document Server

    Bailey, James L; Yang Bing Xin

    2005-01-01

    The Linac Coherent Light Source (LCLS), currently under design, requires beam diagnostic instruments between the magnets in the beam undulator section. Ten wire scanners are planned as one of the primary instruments to characterize electron beam properties. The development of these wire scanners presents several design challenges due to the need for high accuracy and resolution of the wire motion (3 microns tolerance, typical) and the high intensity of the beam (3400 A over an area of 30 micron rms radius). In this paper, we present the technical specification and design criteria for the scanners. We will also present the mechanical design of the UHV-compatible drive and its engineering analysis. Lastly, we present the wire card design and discuss associated thermal and mechanical issues originating from the highly intense x-ray and electron beams.

  5. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  6. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  7. Effect of electron-phonon interaction on the impurity binding energy in a quantum wire

    OpenAIRE

    Chen, Yueh-Nan; Chuu, Der-San; Lin, Yuh-Kae

    2003-01-01

    The effect of electron-optical phonon interaction on the hydrogenic impurity binding energy in a cylindrical quantum wire is studied. By using Landau and Pekar variational method, the hamiltonian is separated into two parts which contain phonon variable and electron variable respectively. A perturbative-variational technique is then employed to construct the trial wavefunction for the electron part. The effect of confined electron-optical phonon interaction on the binding energies of the grou...

  8. Managing electronic resources a LITA guide

    CERN Document Server

    Weir, Ryan O

    2012-01-01

    Informative, useful, current, Managing Electronic Resources: A LITA Guide shows how to successfully manage time, resources, and relationships with vendors and staff to ensure personal, professional, and institutional success.

  9. First-principles study of electron transport through monatomic Al and Na wires

    DEFF Research Database (Denmark)

    Kobayashi, Nobuhiko; Brandbyge, Mads; Tsukada, Masaru

    2000-01-01

    We present first-principles calculations of electron transport, in particular, the conduction channels of monatomic Al and Na atom wires bridged between metallic jellium electrodes. The electronic structures are calculated by the first-principles recursion-transfer matrix method, and the conduction...... channels are investigated using the eigenchannel decomposition (ECD) of the conductance, the local density of states (LDOS), and the current density. The ECD is different from the conventional decomposition of atomic orbitals, and the study of decomposed electronic structures is shown to be effective...... in clarifying the details of transport through atomic wires. We show channel transmissions, channel resolved LDOS, and channel resolved current density, and elucidate the number of conduction channels, the relation between atomic orbitals and the channels, and their dependency on the geometry of the atomic wire...

  10. Recoverable Wire-Shaped Supercapacitors with Ultrahigh Volumetric Energy Density for Multifunctional Portable and Wearable Electronics.

    Science.gov (United States)

    Shi, Minjie; Yang, Cheng; Song, Xuefeng; Liu, Jing; Zhao, Liping; Zhang, Peng; Gao, Lian

    2017-05-24

    Wire-shaped supercapacitors (SCs) based on shape memory materials are of considerable interest for next-generation portable and wearable electronics. However, the bottleneck in this field is how to develop the devices with excellent electrochemical performance while well-maintaining recoverability and flexibility. Herein, a unique asymmetric electrode concept is put forward to fabricate smart wire-shaped SCs with ultrahigh energy density, which is realized by using porous carbon dodecahedra coated on NiTi alloy wire and flexible graphene fiber as yarn electrodes. Notably, the wire-shaped SCs not only exhibit high flexibility that can be readily woven into real clothing but also represent the available recoverable ability. When irreversible plastic deformations happen, the deformed shape of the devices can automatically resume the initial predesigned shape in a warm environment (about 35 °C). More importantly, the wire-shaped SCs act as efficient energy storage devices, which display high volumetric energy density (8.9 mWh/cm(3)), volumetric power density (1080 mW/cm(3)), strong durability in multiple mechanical states, and steady electrochemical behavior after repeated shape recovery processes. Considering their relative facile fabrication technology and excellent electrochemical performance, this asymmetric electrode strategy produced smart wire-shaped supercapacitors desirable for multifunctional portable and wearable electronics.

  11. Direct Measurement of the Electron Energy Relaxation Dynamics in Metallic Wires

    Science.gov (United States)

    Pinsolle, Edouard; Rousseau, Alexandre; Lupien, Christian; Reulet, Bertrand

    2016-06-01

    We present measurements of the dynamical response of thermal noise to an ac excitation in conductors at low temperature. From the frequency dependence of this response function—the (noise) thermal impedance—in the range 1 kHz-1 GHz we obtain direct determinations of the inelastic relaxation times relevant in metallic wires at low temperature: the electron-phonon scattering time and the diffusion time of electrons along the wires. Combining these results with that of resistivity provides a measurement of heat capacity of samples made of thin film. The simplicity and reliability of this technique makes it very promising for future applications in other systems.

  12. Room-Temperature-Processable Wire-Templated Nanoelectrodes for Flexible and Transparent All-Wire Electronics.

    Science.gov (United States)

    Min, Sung-Yong; Lee, Yeongjun; Kim, Se Hyun; Park, Cheolmin; Lee, Tae-Woo

    2017-04-25

    Sophisticated preparation of arbitrarily long conducting nanowire electrodes on a large area is a significant requirement for development of transparent nanoelectronics. We report a position-customizable and room-temperature-processable metallic nanowire (NW) electrode array using aligned NW templates and a demonstration of transparent all-NW-based electronic applications by simple direct-printing. Well-controlled electroless-plating chemistry on a polymer NW template provided a highly conducting Au NW array with a very low resistivity of 7.5 μΩ cm (only 3.4 times higher than that of bulk Au), high optical transmittance (>90%), and mechanical bending stability. This method enables fabrication of all-NW-based electronic devices on various nonplanar surfaces and flexible plastic substrates. Our approach facilitates realization of advanced future electronics.

  13. NaAuS chicken-wire-like semiconductor: Electronic structure and optical properties

    Energy Technology Data Exchange (ETDEWEB)

    Reshak, A.H. [Institute of Complex Systems, FFPW, CENAKVA, University of South Bohemia in CB, Nove Hrady 37333 (Czech Republic); Center of Excellence Geopolymer and Green Technology, School of Material Engineering, University Malaysia Perlis, 01007 Kangar, Perlis (Malaysia); Khan, Saleem Ayaz, E-mail: sayaz_usb@yahoo.com [Institute of Complex Systems, FFPW, CENAKVA, University of South Bohemia in CB, Nove Hrady 37333 (Czech Republic); Kamarudin, H. [Center of Excellence Geopolymer and Green Technology, School of Material Engineering, University Malaysia Perlis, 01007 Kangar, Perlis (Malaysia); Bila, Jiri [Department of Instrumentation and Control Engineering, Faculty of Mechanical Engineering, CTU in Prague, Technicka 4, 166 07 Prague 6 (Czech Republic)

    2014-01-05

    Highlights: • Chicken wire like semiconductor NaAuS was investigated. • Good agreement with experimental data was found. • Electronic charge density of chicken wire like semiconductor NaAuS was obtained. • The calculated uniaxial anisotropy is −0.0005, indicating the strong anisotropy. -- Abstract: The electronic structure, charge density and optical properties of NaAuS a chicken-wire-like semiconductor was calculated using full potential linear augmented plane wave based on density functional theory. The Ceperley-Alder local density approximation, Perdew Becke Ernzerhof Generalized gradient approximation and Engel Voskov Generalized Gradient Approximation were applied to solve the exchange correlation potential. The investigation of band structures and density of states elucidates that Engle Vasko Generalized Gradient Approximation shows close agreement to the experimental data. The calculated valence charge density shows pure ionic nature of Au–Au bond. It becomes partially covalent when Au is connected with two Na atoms. The linear optical susceptibilities of chicken-wire-like NaAuS semiconductor are calculated so as to obtain further insight into the electronic properties. The uniaxial anisotropy is −0.0005, indicating the strong anisotropy of the dielectric function in the NaAuS a chicken-wire-like semiconductor.

  14. Electronic Resources Management Project Presentation 2012

    KAUST Repository

    Ramli, Rindra M.

    2012-11-05

    This presentation describes the electronic resources management project undertaken by the KAUST library. The objectives of this project is to migrate information from MS Sharepoint to Millennium ERM module. One of the advantages of this migration is to consolidate all electronic resources into a single and centralized location. This would allow for better information sharing among library staff.

  15. Implementing CORAL: An Electronic Resource Management System

    Science.gov (United States)

    Whitfield, Sharon

    2011-01-01

    A 2010 electronic resource management survey conducted by Maria Collins of North Carolina State University and Jill E. Grogg of University of Alabama Libraries found that the top six electronic resources management priorities included workflow management, communications management, license management, statistics management, administrative…

  16. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  17. Electron-phonon interaction in a semiconductor quantum wire embedded into the semiconductor medium

    CERN Document Server

    Zharkoj, V P

    2002-01-01

    The renormalization of electron ground state energy due to the different types of interaction with confined (L) and interface (I) phonons in a semiconductor cylindrical quantum wire (QW) embedded into the semiconductor medium by the example of a HgS/CdS nanosystem.

  18. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  19. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  20. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  1. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  2. Quasiparticle properties of a coupled quantum-wire electron-phonon system

    DEFF Research Database (Denmark)

    Hwang, E. H.; Hu, Ben Yu-Kuang; Sarma, S. Das

    1996-01-01

    We study leading-order many-body effects of longitudinal-optical phonons on electronic properties of one-dimensional quantum-wire systems. We calculate the quasiparticle properties of a weakly polar one-dimensional electron gas in the presence of both electron-phonon and electron-electron...... interactions, The leading-order dynamical screening approximation (GW approximation) is used to obtain the electron self-energy, the quasiparticle spectral function, and the quasiparticle damping rate in our calculation by treating electrons and phonons on an equal footing. Our theory includes effects (within...... the random-phase approximation) of Fermi statistics, Landau damping, plasmon-phonon mode coupling, phonon renormalization, dynamical screening, and impurity scattering. In general, electron-electron and electron-phonon many-body renormalization effects are found to be nonmultiplicative and nonadditive in our...

  3. Distribution of Energy Deposited in Plastic Tubing and Copper-Wire Insulation by Electron Beam Irradiation

    DEFF Research Database (Denmark)

    Pedersen, Walther Batsberg; Miller, Arne; Pejtersen, K.

    1978-01-01

    as uniformly as possible, usually by means of a multipass arrangement. In the present study, using irradiation by a scanned 0.4 MeV electron beam, measurements were made of high-resolution distributions of absorbed dose in polyethylene tubing and copper wire coated with polyethylene, nylon, or polyvinyl...... chloride insulation. Radiochromic dye films equivalent to the insulating materials were used as accurate dosimeters having a response independent of dose rate. Irradiations were in various geometries, wire and plastic thicknesses, positions along the beam scan, and with different backing materials near...

  4. PRINCIPLES OF CONTENT FORMATION EDUCATIONAL ELECTRONIC RESOURCE

    Directory of Open Access Journals (Sweden)

    О Ю Заславская

    2017-12-01

    Full Text Available The article considers modern possibilities of information and communication technologies for the design of electronic educational resources. The conceptual basis of the open educational multimedia system is based on the modular architecture of the electronic educational resource. The content of the electronic training module can be implemented in several versions of the modules: obtaining information, practical exercises, control. The regularities in the teaching process in modern pedagogical theory are considered: general and specific, and the principles for the formation of the content of instruction at different levels are defined, based on the formulated regularities. On the basis of the analysis, the principles of the formation of the electronic educational resource are determined, taking into account the general and didactic patterns of teaching.As principles of the formation of educational material for obtaining information for the electronic educational resource, the article considers: the principle of methodological orientation, the principle of general scientific orientation, the principle of systemic nature, the principle of fundamentalization, the principle of accounting intersubject communications, the principle of minimization. The principles of the formation of the electronic training module of practical studies in the article include: the principle of systematic and dose based consistency, the principle of rational use of study time, the principle of accessibility. The principles of the formation of the module for monitoring the electronic educational resource can be: the principle of the operationalization of goals, the principle of unified identification diagnosis.

  5. Electronic Resources Management System: Recommendation Report 2017

    KAUST Repository

    Ramli, Rindra M.

    2017-05-01

    This recommendation report provides an overview of the selection process for the new Electronic Resources Management System. The library has decided to move away from Innovative Interfaces Millennium ERM module. The library reviewed 3 system as potential replacements namely: Proquest 360 Resource Manager, Ex Libris Alma and Open Source CORAL ERMS. After comparing and trialling the systems, it was decided to go for Proquest 360 Resource Manager.

  6. CHALLENGES OF ELECTRONIC INFORMATION RESOURCES IN ...

    African Journals Online (AJOL)

    This paper discusses the role of policy for proper and efficient library services in the electronic era. It points out some of the possible dangers of embarking in electronic resources without a proper focus at hand. Thus, it calls for today's librarians and policy makers to brainstorm and come up with working policies suitable to ...

  7. Enhancing electron transport in molecular wires by insertion of a ferrocene center.

    Science.gov (United States)

    Sun, Yan-Yan; Peng, Zheng-Lian; Hou, Rong; Liang, Jing-Hong; Zheng, Ju-Fang; Zhou, Xiao-Yi; Zhou, Xiao-Shun; Jin, Shan; Niu, Zhen-Jiang; Mao, Bing-Wei

    2014-02-14

    We have determined the conductance of alkane-linked ferrocene molecules with carboxylic acid anchoring groups using the STM break junction technique, and three sets of conductance values were found, i.e. high conductance (HC), medium conductance (MC) and low conductance (LC) values. The enhancing effect of the incorporated ferrocene on the electron transport in saturated alkane molecular wires is demonstrated by the increased conductance of the ferrocene molecules, attributed to the reduction of the tunneling barrier and the HOMO-LUMO gap induced by the insertion of ferrocene. Furthermore, the electron-withdrawing carbonyl group on the unconjugated backbone has little or no influence on single-molecule conductance. The current work provides a feasible approach for the design of high-performance molecular wires.

  8. Inelastic electron and Raman scattering from the collective excitations in quantum wires: Zero magnetic field

    Directory of Open Access Journals (Sweden)

    Manvir S. Kushwaha

    2013-04-01

    Full Text Available The nanofabrication technology has taught us that an m-dimensional confining potential imposed upon an n-dimensional electron gas paves the way to a quasi-(n-m-dimensional electron gas, with m ⩽ n and 1 ⩽ n, m ⩽ 3. This is the road to the (semiconducting quasi-n dimensional electron gas systems we have been happily traversing on now for almost two decades. Achieving quasi-one dimensional electron gas (Q-1DEG [or quantum wire(s for more practical purposes] led us to some mixed moments in this journey: while the reduced phase space for the scattering led us believe in the route to the faster electron devices, the proximity to the 1D systems left us in the dilemma of describing it as a Fermi liquid or as a Luttinger liquid. No one had ever suspected the potential of the former, but it took quite a while for some to convince the others on the latter. A realistic Q-1DEG system at the low temperatures is best describable as a Fermi liquid rather than as a Luttinger liquid. In the language of condensed matter physics, a critical scrutiny of Q-1DEG systems has provided us with a host of exotic (electronic, optical, and transport phenomena unseen in their higher- or lower-dimensional counterparts. This has motivated us to undertake a systematic investigation of the inelastic electron scattering (IES and the inelastic light scattering (ILS from the elementary electronic excitations in quantum wires. We begin with the Kubo's correlation functions to derive the generalized dielectric function, the inverse dielectric function, and the Dyson equation for the dynamic screened potential in the framework of Bohm-Pines’ random-phase approximation. These fundamental tools then lead us to develop methodically the theory of IES and ILS for the Q-1DEG systems. As an application of the general formal results, which know no bounds regarding the subband occupancy, we compute the density of states, the Fermi energy, the full excitation spectrum [comprised of

  9. Depollution benchmarks for capacitors, batteries and printed wiring boards from waste electrical and electronic equipment (WEEE)

    Energy Technology Data Exchange (ETDEWEB)

    Savi, Daniel, E-mail: d.savi@umweltchemie.ch [Dipl. Environmental Sci. ETH, büro für umweltchemie, Zurich (Switzerland); Kasser, Ueli [Lic. Phil. Nat. (Chemist), büro für umweltchemie, Zurich (Switzerland); Ott, Thomas [Dipl. Phys. ETH, Institute of Applied Simulation, Zurich University of Applied Sciences, Wädenswil (Switzerland)

    2013-12-15

    Highlights: • We’ve analysed data on the dismantling of electronic and electrical appliances. • Ten years of mass balance data of more than recycling companies have been considered. • Percentages of dismantled batteries, capacitors and PWB have been studied. • Threshold values and benchmarks for batteries and capacitors have been identified. • No benchmark for the dismantling of printed wiring boards should be set. - Abstract: The article compiles and analyses sample data for toxic components removed from waste electronic and electrical equipment (WEEE) from more than 30 recycling companies in Switzerland over the past ten years. According to European and Swiss legislation, toxic components like batteries, capacitors and printed wiring boards have to be removed from WEEE. The control bodies of the Swiss take back schemes have been monitoring the activities of WEEE recyclers in Switzerland for about 15 years. All recyclers have to provide annual mass balance data for every year of operation. From this data, percentage shares of removed batteries and capacitors are calculated in relation to the amount of each respective WEEE category treated. A rationale is developed, why such an indicator should not be calculated for printed wiring boards. The distributions of these de-pollution indicators are analysed and their suitability for defining lower threshold values and benchmarks for the depollution of WEEE is discussed. Recommendations for benchmarks and threshold values for the removal of capacitors and batteries are given.

  10. Energetics and electronic properties of Pt wires of different topologies on monolayer MoSe{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Jamdagni, Pooja, E-mail: j.poojaa1228@gmail.com; Ahluwalia, P. K. [Physics Department, Himachal Pradesh University, Shimla, Himachal Pradesh, India 171005 (India); Kumar, Ashok [Centre for Physical Sciences, School of Basic and Applied Sciences, Central University of Panjab, Bathinda, India, 151001 (India); Thakur, Anil [Physics Department, Govt. Collage Solan, Himachal Pradesh, India, 173212 (India); Pandey, Ravindra [Physics Department, Michigan Technological University, Houghton (United States)

    2016-05-23

    The energetics and electronic properties of different topology of Pt wires including linear, zigzag and ladder structures on MoSe{sub 2} monolayer have been investigated in the framework of density functional theory (DFT). The predicted order of stability of Pt wire on MoSe{sub 2} monolayer is found to be: linear > ladder > zigzag. Pt wires induce states near the Fermi level of MoSe{sub 2} that results into metallic characteristics of Pt-wire/MoSe{sub 2} assembled system. Valence band charge density signifies most of the contribution from Pt atoms near the Fermi energy of assembled wire/MoSe{sub 2} system. These findings are expected to be important for the fabrication of devices based on MoSe{sub 2} layers for flexible nanoelectronics.

  11. Electron-phonon interaction effect on the energy levels and diamagnetic susceptibility of quantum wires: Parallelogram and triangle cross section

    Science.gov (United States)

    Khordad, R.; Bahramiyan, H.

    2014-03-01

    In this paper, optical phonon modes are studied within the framework of dielectric continuum approach for parallelogram and triangular quantum wires, including the derivation of the electron-phonon interaction Hamiltonian and a discussion on the effects of this interaction on the electronic energy levels. The polaronic energy shift is calculated for both ground-state and excited-state electron energy levels by applying the perturbative approach. The effects of the electron-phonon interaction on the expectation value of r2 and diamagnetic susceptibility for both quantum wires are discussed.

  12. Rapid Embedded Wire Heating via Resistive Guiding of Laser-Generated Fast Electrons as a Hydrodynamic Driver

    CERN Document Server

    Robinson, A P L; Pasley, J

    2014-01-01

    Resistively guiding laser-generated fast electron beams in targets consisting of a resistive wire embedded in lower $Z$ material should allow one to rapidly heat the wire to over 100eV over a substantial distance without strongly heating the surrounding material. On the multi-ps timescale this can drive hydrodynamic motion in the surrounding material. Thus ultra-intense laser solid interactions have the potential as a controlled driver of radiation hydrodynamics in solid density material. In this paper we assess the laser and target parameters needed to achieve such rapid and controlled heating of the embedded wire.

  13. Library training to promote electronic resource usage

    DEFF Research Database (Denmark)

    Frandsen, Tove Faber; Tibyampansha, Dativa; Ibrahim, Glory

    2017-01-01

    Purpose: Increasing the usage of electronic resources is an issue of concern for many libraries all over the world. Several studies stress the importance of information literacy and instruction in order to increase the usage. Design/methodology/approach: The present article presents the results...... of implementing training programmes to encourage the use of the e-library. Findings: Training sessions increase the usage of library e-resources significantly; however, the effect seems to be short-lived and training sessions alone may not increase the overall long-term usage. Originality/value: The present paper...... presents a study of training sessions as means to increase awareness and usage of library e-resources. Implications for the planning of training are discussed....

  14. Library Training to Promote Electronic Resource Usage

    DEFF Research Database (Denmark)

    Frandsen, Tove Faber; Tibyampansha, Dativa; Ibrahim, Glory

    2017-01-01

    Purpose: Increasing the usage of electronic resources is an issue of concern for many libraries all over the world. Several studies stress the importance of information literacy and instruction in order to increase the usage. Design/methodology/approach: The present article presents the results...... of implementing training programmes to encourage the use of the e-library. Findings: Training sessions increase the usage of library e-resources significantly; however, the effect seems to be short-lived and training sessions alone may not increase the overall long-term usage. Originality/value: The present paper...... presents a study of training sessions as means to increase awareness and usage of library e-resources. Implications for the planning of training are discussed....

  15. High-contrast laser acceleration of relativistic electrons in solid cone-wire targets

    Energy Technology Data Exchange (ETDEWEB)

    Higginson, D. P. [Univ. of California-San Diego, La Jolla, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Link, A. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Sawada, H. [Univ. of California-San Diego, La Jolla, CA (United States); Wilks, S. C. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chawla, S. R. [Univ. of California-San Diego, La Jolla, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Chen, C. D. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jarrott, L. C. [Univ. of California-San Diego, La Jolla, CA (United States); Flippo, K. A. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); McLean, H. S. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Patel, P. K. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Perez, F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Beg, F. N. [Univ. of California-San Diego, La Jolla, CA (United States); Bartal, T. [Univ. of California-San Diego, La Jolla, CA (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Wei, M. S. [General Atomics, San Diego, CA (United States)

    2015-12-31

    Optimization of electron coupling into small solid angles is of extreme importance to applications, such as Fast Ignition, that require maximum electron energy deposition within a small volume. To optimize this coupling, we use the ultra-high-contrast Trident laser, which remains below intensity of 1011 W/cm2 until < 0.1 ns before the main pulse, while still attaining high-energy, 75 J, and peak intensity of 5 x 1019 W/cm2. Using a cone-wire target, we find that the coupling into the 40 μm diameter wire is increased by a factor of 2.7x over the low-contrast Titan laser at similar peak intensity. Full-scale simulations are used to model the laser interaction and quantitatively reproduce the experimental results. These show that increase in coupling is due to both a closer interaction, as well as the reduction of laser filamentation and self-focusing.

  16. Calculation of electrical transport properties and electron entanglement in inhomogeneous quantum wires

    Directory of Open Access Journals (Sweden)

    A A Shokri

    2013-10-01

    Full Text Available In this paper, we have investigated the spin-dependent transport properties and electron entanglement in a mesoscopic system, which consists of two semi-infinite leads (as source and drain separated by a typical quantum wire with a given potential. The properties studied include current-voltage characteristic, electrical conductivity, Fano factor and shot noise, and concurrence. The calculations are based on the transfer matrix method within the effective mass approximation. Using the Landauer formalism and transmission coefficient, the dependence of the considered quantities on type of potential well, length and width of potential well, energy of transmitted electron, temperature and the voltage have been theoretically studied. Also, the effect of the above-mentioned factors has been investigated in the nanostructure. The application of the present results may be useful in designing spintronice devices.

  17. Electronic resource management systems a workflow approach

    CERN Document Server

    Anderson, Elsa K

    2014-01-01

    To get to the bottom of a successful approach to Electronic Resource Management (ERM), Anderson interviewed staff at 11 institutions about their ERM implementations. Among her conclusions, presented in this issue of Library Technology Reports, is that grasping the intricacies of your workflow-analyzing each step to reveal the gaps and problems-at the beginning is crucial to selecting and implementing an ERM. Whether the system will be used to fill a gap, aggregate critical data, or replace a tedious manual process, the best solution for your library depends on factors such as your current soft

  18. Depollution benchmarks for capacitors, batteries and printed wiring boards from waste electrical and electronic equipment (WEEE).

    Science.gov (United States)

    Savi, Daniel; Kasser, Ueli; Ott, Thomas

    2013-12-01

    The article compiles and analyses sample data for toxic components removed from waste electronic and electrical equipment (WEEE) from more than 30 recycling companies in Switzerland over the past ten years. According to European and Swiss legislation, toxic components like batteries, capacitors and printed wiring boards have to be removed from WEEE. The control bodies of the Swiss take back schemes have been monitoring the activities of WEEE recyclers in Switzerland for about 15 years. All recyclers have to provide annual mass balance data for every year of operation. From this data, percentage shares of removed batteries and capacitors are calculated in relation to the amount of each respective WEEE category treated. A rationale is developed, why such an indicator should not be calculated for printed wiring boards. The distributions of these de-pollution indicators are analysed and their suitability for defining lower threshold values and benchmarks for the depollution of WEEE is discussed. Recommendations for benchmarks and threshold values for the removal of capacitors and batteries are given. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. A theoretical study of the atomic and electronic structures of three prospective atomic scale wire systems

    CERN Document Server

    Shevlin, S A

    2001-01-01

    transport properties of the line are also calculated. Finally we find which of the two models of the (4x1)-Si(111)-ln reconstruction is thermodynamically favoured in a supercell geometry. We use ab initio plane wave techniques in the Local-Density-Approximation, and calculate and compare the electronic structure of the two models with respect to the characteristic energies for electron dispersion along and across the chain structures. We also consider the effects of electronic structure on the in-plane transport properties of the indium lines. The structural and electronic properties of several candidate atomic scale wires are analysed. Three candidates are studied: the trans-polyacetylene molecule, the silicon line on the (001) face of cubic silicon carbide (the (nx2) series of reconstructions) and the indium chain on the (111) face of silicon carbide (the (4x1) reconstruction). We use the polyacetylene molecule as a test-bed for the techniques that we use to calculate transport properties in an empirically ...

  20. A Miniaturized Linear Wire Ion Trap with Electron Ionization and Single Photon Ionization Sources

    Science.gov (United States)

    Wu, Qinghao; Tian, Yuan; Li, Ailin; Andrews, Derek; Hawkins, Aaron R.; Austin, Daniel E.

    2017-05-01

    A linear wire ion trap (LWIT) with both electron ionization (EI) and single photon ionization (SPI) sources was built. The SPI was provided by a vacuum ultraviolet (VUV) lamp with the ability to softly ionize organic compounds. The VUV lamp was driven by a pulse amplifier, which was controlled by a pulse generator, to avoid the detection of photons during ion detection. Sample gas was introduced through a leak valve, and the pressure in the system is shown to affect the signal-to-noise ratio and resolving power. Under optimized conditions, the limit of detection (LOD) for benzene was 80 ppbv using SPI, better than the LOD using EI (137 ppbv). System performance was demonstrated by distinguishing compounds in different classes from gasoline.

  1. Using Powder Cored Tubular Wire Technology to Enhance Electron Beam Freeform Fabricated Structures

    Science.gov (United States)

    Gonzales, Devon; Liu, Stephen; Domack, Marcia; Hafley, Robert

    2016-01-01

    Electron Beam Freeform Fabrication (EBF3) is an additive manufacturing technique, developed at NASA Langley Research Center, capable of fabricating large scale aerospace parts. Advantages of using EBF3 as opposed to conventional manufacturing methods include, decreased design-to-product time, decreased wasted material, and the ability to adapt controls to produce geometrically complex parts with properties comparable to wrought products. However, to fully exploit the potential of the EBF3 process development of materials tailored for the process is required. Powder cored tubular wire (PCTW) technology was used to modify Ti-6Al-4V and Al 6061 feedstock to enhance alloy content, refine grain size, and create a metal matrix composite in the as-solidified structures, respectively.

  2. Front-end Electronics Test for the LHCb Muon Wire Chambers

    CERN Document Server

    Nobrega, R; Carboni, G; Massafferri, A; Santovetti, E

    2007-01-01

    This document describes the apparatus and procedures implemented to test Multi Wire Proportional Chambers (MWPC) after front-end assembly for the LHCb Muon Detector. Results of measurements of key noise parameters are also described. Given a fully equipped chamber, this system is able to diagnose every channel performing an analysis of front-end output drivers’ response and noise rate versus threshold. Besides, it allows to assess if the noise rate at the experiment threshold region is within appropriate limits. Aiming at an automatic, fast and user-friendly system for mass production tests of MWPC, the project has foreseen as well electronic identification of every chamber and front-end board, and data archiving in such a way to make it available to the Experiment Control System (ECS) while in operation.

  3. Front-end electronics and data acquisition system for a multi-wire 3D gas tracker

    Energy Technology Data Exchange (ETDEWEB)

    Łojek, K. [Institute of Physics, Jagiellonian University, 30348 Cracow (Poland); Rozpȩdzik, D., E-mail: dagmara.rozpedzik@uj.edu.pl [Institute of Physics, Jagiellonian University, 30348 Cracow (Poland); Bodek, K. [Institute of Physics, Jagiellonian University, 30348 Cracow (Poland); Perkowski, M. [Institute of Physics, Jagiellonian University, 30348 Cracow (Poland); Instituut voor Kern-en Stralingsfysica, University of Leuven, 3001 Leuven (Belgium); Severijns, N. [Instituut voor Kern-en Stralingsfysica, University of Leuven, 3001 Leuven (Belgium)

    2015-12-01

    This paper presents the design and implementation of the front-end electronics and the data acquisition (DAQ) system for readout of multi-wire drift chambers (MWDC). Apart of the conventional drift time measurement the system delivers the hit position along the wire utilizing the charge division technique. The system consists of preamplifiers, and analog and digital boards sending data to a back-end computer via an Ethernet interface. The data logging software formats the received data and enables an easy access to the data analysis software. The use of specially designed preamplifiers and peak detectors allows the charge-division readout of the low resistance signal wire. The implication of the charge-division circuitry onto the drift time measurement was studied and the overall performance of the electronic system was evaluated in dedicated off-line tests.

  4. PS wire chamber

    CERN Multimedia

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  5. 2015 Utilization of Electronic Information Resources in Ramat

    African Journals Online (AJOL)

    Utilization of Electronic Information Resources in Ramat Library, University of Maiduguri, Nigeria. 195 ... Information Impact Vol. 6 (2) 2015. Introduction. The concept of "e-resources" which stands for electronic resources has become a global phenomenon which emerged as a ... Science, Delta State University Abaraka,.

  6. Use of Electronic Resources in a Private University in Nigeria ...

    African Journals Online (AJOL)

    The study examined awareness and constraints in the use of electronic resources by lecturers and students of Ajayi Crowther University, Oyo, Nigeria. It aimed at justifying the resources expended in the provision of electronic resources in terms of awareness, patronage and factors that may be affecting awareness and use ...

  7. Electronic Resource Management System. Vernetzung von Lizenzinformationen

    Directory of Open Access Journals (Sweden)

    Michaela Selbach

    2014-12-01

    Full Text Available In den letzten zehn Jahren spielen elektronische Ressourcen im Bereich der Erwerbung eine zunehmend wichtige Rolle: Eindeutig lässt sich hier ein Wandel in den Bibliotheken (fort vom reinen Printbestand zu immer größeren E-Only-Beständen feststellen. Die stetig wachsende Menge an E-Ressourcen und deren Heterogenität stellt Bibliotheken vor die Herausforderung, die E-Ressourcen effizient zu verwalten. Nicht nur Bibliotheken, sondern auch verhandlungsführende Institutionen von Konsortial- und Allianzlizenzen benötigen ein geeignetes Instrument zur Verwaltung von Lizenzinformationen, welches den komplexen Anforderungen moderner E-Ressourcen gerecht wird. Die Deutsche Forschungsgemeinschaft (DFG unterstützt ein Projekt des Hochschulbibliothekszentrums des Landes Nordrhein-Westfalen (hbz, der Universitätsbibliothek Freiburg, der Verbundzentrale des Gemeinsamen Bibliotheksverbundes (GBV und der Universitätsbibliothek Frankfurt, in dem ein bundesweit verfügbares Electronic Ressource Managementsystem (ERMS aufgebaut werden soll. Ein solches ERMS soll auf Basis einer zentralen Knowledge Base eine einheitliche Nutzung von Daten zur Lizenzverwaltung elektronischer Ressourcen auf lokaler, regionaler und nationaler Ebene ermöglichen. Statistische Auswertungen, Rechteverwaltung für alle angeschlossenen Bibliotheken, kooperative Datenpflege sowie ein über standardisierte Schnittstellen geführter Datenaustausch stehen bei der Erarbeitung der Anforderungen ebenso im Fokus wie die Entwicklung eines Daten- und Funktionsmodells. In the last few years the importance of electronic resources in library acquisitions has increased significantly. There has been a shift from mere print holdings to both e- and print combinations and even e-only subscriptions. This shift poses a double challenge for libraries: On the one hand they have to provide their e-resource collections to library users in an appealing way, on the other hand they have to manage these

  8. Raman spectroscopy as a tool to investigate the structure and electronic properties of carbon-atom wires

    Directory of Open Access Journals (Sweden)

    Alberto Milani

    2015-02-01

    Full Text Available Graphene, nanotubes and other carbon nanostructures have shown potential as candidates for advanced technological applications due to the different coordination of carbon atoms and to the possibility of π-conjugation. In this context, atomic-scale wires comprised of sp-hybridized carbon atoms represent ideal 1D systems to potentially downscale devices to the atomic level. Carbon-atom wires (CAWs can be arranged in two possible structures: a sequence of double bonds (cumulenes, resulting in a 1D metal, or an alternating sequence of single–triple bonds (polyynes, expected to show semiconducting properties. The electronic and optical properties of CAWs can be finely tuned by controlling the wire length (i.e., the number of carbon atoms and the type of termination (e.g., atom, molecular group or nanostructure. Although linear, sp-hybridized carbon systems are still considered elusive and unstable materials, a number of nanostructures consisting of sp-carbon wires have been produced and characterized to date. In this short review, we present the main CAW synthesis techniques and stabilization strategies and we discuss the current status of the understanding of their structural, electronic and vibrational properties with particular attention to how these properties are related to one another. We focus on the use of vibrational spectroscopy to provide information on the structural and electronic properties of the system (e.g., determination of wire length. Moreover, by employing Raman spectroscopy and surface enhanced Raman scattering in combination with the support of first principles calculations, we show that a detailed understanding of the charge transfer between CAWs and metal nanoparticles may open the possibility to tune the electronic structure from alternating to equalized bonds.

  9. Electronic human resource management: Enhancing or entrancing?

    Directory of Open Access Journals (Sweden)

    Paul Poisat

    2017-01-01

    Full Text Available Orientation: This article provides an investigation into the current level of development of the body of knowledge related to electronic human resource management (e-HRM by means of a qualitative content analysis. Several aspects of e-HRM, namely definitions of e-HRM, the theoretical perspectives around e-HRM, the role of e-HRM, the various types of e-HRM and the requirements for successful e-HRM, are examined.Research purpose: The purpose of the article was to determine the status of e-HRM and examine the studies that report on the link between e-HRM and organisational productivity.Motivation for the study: e-HRM has the capacity to improve organisational efficiency and leverage the role of human resources (HR as a strategic business partner.Main findings: The notion that the implementation of e-HRM will lead to improved organisational productivity is commonly assumed; however, empirical evidence in this regard was found to be limited.Practical/managerial implications: From the results of this investigation it is evident that more research is required to gain a greater understanding of the influence of e-HRM on organisational productivity, as well as to develop measures for assessing this influence.Contribution: This article proposes additional areas to research and measure when investigating the effectiveness of e-HRM. It provides a different lens from which to view e-HRM assessment whilst keeping it within recognised HR measurement parameters (the HR value chain. In addition, it not only provides areas for measuring e-HRM’s influence but also provides important clues as to how the measurements may be approached. 

  10. Utilization of electronic information resources by academic staff at ...

    African Journals Online (AJOL)

    The study investigated the utilization of Electronic Information resources by the academic staff of Makerere University in Uganda. It examined the academic staff awareness of the resources available, the types of resources provided by the Makerere University Library, the factors affecting resource utilization. The study was ...

  11. Electronic Resource Management: Functional Integration in Technical Services

    OpenAIRE

    Stachokas, George

    2014-01-01

    Declining usage of print materials along with increasing usage of electronic resources makes it necessary for libraries to reallocate personnel from print management to electronic resources management. Electronic resources management should be the primary focus of technical services units in the early twenty-first century. Print should no longer be treated as the default format, and the work of library staff must be reorganized and reintegrated with librarians and other professionals to refle...

  12. Inspection of anode and field wires for the COMPASS drift chamber, DC5, with Environmental Scanning Electron Microscope

    Science.gov (United States)

    Cyuzuzo, Sonia

    2014-09-01

    The COMPASS experiment at CERN uses a secondary pion beam from the Super Proton Synchrotron (SPS) at CERN to explore the spin structure of nucleons. A new drift chamber, DC5, will be integrated into the COMPASS spectrometer to replace an aging straw tube detector. DC5 will detect muon pairs from Drell-Yan scattering of a pion-beam off a transversely polarized proton target. This data will be used to determine the correlation between transverse proton spin and the intrinsic transverse momentum of up-quarks inside the proton, the Sivers effect. DC5 is a large area planar drift chamber with 8 layers of anode-frames made of G10 fiberglass-epoxy. The G10 frames support printed circuit boards for soldering 20 μm diameter anode and 100 μm diameter field wires. The anode planes are sandwiched by 13 graphite coated Mylar cathode planes. To ensure a well-functioning of DC5, the wires were carefully tested. An optical inspection and a spectral analysis was performed with an Environmental Scanning Electron Microscope (ESEM) to verify the composition and dimensions and the integrity of the gold plating on the surface of these wires. The spectra of the wires were studied at 10 and 30 keV. The COMPASS experiment at CERN uses a secondary pion beam from the Super Proton Synchrotron (SPS) at CERN to explore the spin structure of nucleons. A new drift chamber, DC5, will be integrated into the COMPASS spectrometer to replace an aging straw tube detector. DC5 will detect muon pairs from Drell-Yan scattering of a pion-beam off a transversely polarized proton target. This data will be used to determine the correlation between transverse proton spin and the intrinsic transverse momentum of up-quarks inside the proton, the Sivers effect. DC5 is a large area planar drift chamber with 8 layers of anode-frames made of G10 fiberglass-epoxy. The G10 frames support printed circuit boards for soldering 20 μm diameter anode and 100 μm diameter field wires. The anode planes are sandwiched by 13

  13. Self-alignment of Co adatoms on in atomic wires by quasi-one-dimensional electron-gas-meditated interactions.

    Science.gov (United States)

    Liu, Canhua; Uchihashi, Takashi; Nakayama, Tomonobu

    2008-10-03

    Low-density Co atoms are found to self-align on the Si(111)-(4 x 1)-In surface in the direction of In atomic wires at incommensurate adsorption sites. Indirect interaction between a pair of Co adatoms is investigated through a site distribution function of adatoms determined with scanning tunneling microscopy. In the direction of self-alignment, the potential of the mean force between two Co adatoms is long-range and oscillatory with multiple frequencies, which correlate strongly to the electronic scattering vectors of the surface-state bands at the Fermi level. We thus attribute the Co-Co interaction to that mediated by a quasi-one-dimensional electron gas confined within the In atomic wires.

  14. Effects of secondary electrons from heavy primary cosmic rays in a MWPC hodoscope. [Multi-Wire Proportional Counter

    Science.gov (United States)

    Derrickson, J. H.; Parnell, T. A.; Gregory, J. C.

    1978-01-01

    A multi-wire proportional counter hodoscope, efficient for both primary track recovery and reading out all wires set by secondary electrons, was flown in a balloon flight experiment covering the range of cosmic ray charge from 4 to 28 and kinetic energy T greater than 0.5 GeV/nucleon. Data on the secondary electron effects in the hodoscope is presented for primary nuclei between C and Fe and kinetic energies between 0.6 and 7.0 GeV/nucleon. The total number of affected anodes in the hodoscope is seen to increase linearly with the cosmic ray change, with a slope that depends strongly on energy over this limited primary energy range.

  15. impact of the use of electronic resources on research output

    African Journals Online (AJOL)

    manda

    Abstract. This paper examines the impact of the use of electronic information resources on research output in the universities in Tanzania. Research for this paper was conducted in five public universities in Tanzania with varied levels of access to electronic information resources. The selection of the sample universities was ...

  16. Page 170 Use of Electronic Resources by Undergraduates in Two ...

    African Journals Online (AJOL)

    The evolution of information technology in the twentieth century has influenced students' use of information resources. Today, many students access information electronically via the Internet using desktop, laptop, palmtop and mobile phones. Electronic resources supply all the information that a library provides through ...

  17. The impact of electronic information resource use on research output

    African Journals Online (AJOL)

    This paper examines the impact of the use of electronic information resources on research output in the universities in Tanzania. Research for this paper was conducted in five public universities in Tanzania with varied levels of access to electronic information resources. The selection of the sample universities was ...

  18. Use of electronic resources by undergraduates in two selected ...

    African Journals Online (AJOL)

    The purpose of this study is to know the extent of use of electronic resources and identify the type of electronic resources used by undergraduates in universities in Nigeria. Questionnaire was used for data collection. The study population includes all undergraduate students in the faculty of engineering in Niger Delta ...

  19. The Role of the Acquisitions Librarian in Electronic Resources Management

    Science.gov (United States)

    Pomerantz, Sarah B.

    2010-01-01

    With the ongoing shift to electronic formats for library resources, acquisitions librarians, like the rest of the profession, must adapt to the rapidly changing landscape of electronic resources by keeping up with trends and mastering new skills related to digital publishing, technology, and licensing. The author sought to know what roles…

  20. Charpak hemispherical wire chamber

    CERN Multimedia

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  1. Fault Diagnostics in Power Electronics Based Brake-by-Wire Systems

    Science.gov (United States)

    2006-05-22

    brake-by-wire system as soon as they occur. We developed a brake-by-wire ( BBW ) system model using Simplorer software that implements the full control...the BBW system. It has the capabilities of detecting faulty conditions immediately after they occur, and pinpointing to specific faulty conditions...within less than 0.02s on the bench setup BBW . The performance of the hierarchical fuzzy diagnostic system is also compared with two other fuzzy

  2. Use of electronic information resources in goverment libraries

    Directory of Open Access Journals (Sweden)

    Simona Omahen

    2003-01-01

    Full Text Available The article presents the use of electronic information resources in government libraries in Slovenia. It starts with the definition of government libraries and electronic publications. On a selected sample of government libraries, the state of the usage of electronic information resources in government libraries was studied. On the basis of interviews, carried out in five government libraries, it was established that government libraries mostly do not focus on, or even think about, the use of electronic information resources. What they have and use seems self-evident to them.

  3. Electronic information resources for food toxicology.

    Science.gov (United States)

    Winter, Carl K

    2002-04-25

    This manuscript provides a brief overview of many useful Internet resources concerning food toxicology. Specific topic areas include pesticide residues, food additives, natural toxins, environmental contaminants, and food allergies; numerous links and evaluative information are provided within each topic area. Several helpful Internet resources have been identified and include government, industry, academic, and consumer sites.

  4. Structural evolution of a Ta-filament during hot-wire chemical vapour deposition of Silicon investigated by electron backscatter diffraction

    CSIR Research Space (South Africa)

    Oliphant, CJ

    2012-03-01

    Full Text Available In this study we investigate the structural changes of a burnt-out tantalum filament that was operated at typical hydrogenated nanocrystalline silicon synthesis conditions in our hot-wire chemical vapour deposition chamber. Scanning electron...

  5. A hot-wire probe for thermal measurements of nanowires and nanotubes inside a transmission electron microscope.

    Science.gov (United States)

    Dames, C; Chen, S; Harris, C T; Huang, J Y; Ren, Z F; Dresselhaus, M S; Chen, G

    2007-10-01

    A hot wire probe has been developed for use inside a transmission electron microscope to measure the thermal resistance of individual nanowires, nanotubes, and their contacts. No microfabrication is involved. The probe is made from a platinum Wollaston wire and is pretensioned to minimize the effects of thermal expansion, intrinsic thermal vibrations, and Lorentz forces. An in situ nanomanipulator is used to select a particular nanowire or nanotube for measurement, and contacts are made with liquid metal droplets or by electron-beam induced deposition. Detailed thermal analysis shows that for best sensitivity, the thermal resistance of the hot-wire probe should be four times that of the sample, but a mismatch of more than two orders of magnitude may be acceptable. Data analysis using the ratio of two ac signals reduces the experimental uncertainty. The range of detectable sample thermal resistances spans from approximately 10(3) to 10(9) KW. The probe can also be adapted for measurements of the electrical conductance and Seebeck coefficient of the same sample. The probe was used to study a multiwalled carbon nanotube with liquid Ga contacts. The measured thermal resistance of 3.3 x 10(7) KW had a noise level of approximately +/-3% and was repeatable to within +/-10% upon breaking and re-making the contact.

  6. Electronic resources preferred by pediatric hospitalists for clinical care.

    Science.gov (United States)

    Beck, Jimmy B; Tieder, Joel S

    2015-10-01

    There is little research on pediatric hospitalists' use of evidence-based resources. The aim of this study was to determine the electronic resources that pediatric hospitalists prefer. Using a web-based survey, the authors determined hospitalists' preferred electronic resources, as well as their attitudes toward lifelong learning, practice, and experience characteristics. One hundred sixteen hospitalists completed the survey. The most preferred resource for general information, patient handouts, and treatment was UpToDate. Online search engines were ranked second for general information and patient handouts. Pediatric hospitalists tend to utilize less rigorous electronic resources such as UpToDate and Google. These results can set a platform for discussing the quality of resources that pediatric hospitalists use.

  7. Improving Electronic Resources through Holistic Budgeting

    Science.gov (United States)

    Kusik, James P.; Vargas, Mark A.

    2009-01-01

    To establish a more direct link between its collections and the educational goals of Saint Xavier University, the Byrne Memorial Library has adopted a "holistic" approach to collection development. This article examines how traditional budget practices influenced the library's selection of resources and describes how holistic collection…

  8. Electronic learning and open educational resources in the health ...

    African Journals Online (AJOL)

    Electronic learning and open educational resources in the health sciences in Ghana. ... Methods: Two e-learning materials were developed, one on the polymerase ... 95% (18) at UG report having access to a computer for learning purposes.

  9. Integrating Electronic Resources into the Library Catalog: A Collaborative Approach.

    Science.gov (United States)

    Herrera, Gail; Aldana, Lynda

    2001-01-01

    Describes a project at the University of Mississippi Libraries to catalog purchased electronic resources so that access to these resources is available only via the Web-based library catalog. Discusses collaboration between cataloging and systems personnel; and describes the MARC catalog record field that contains the information needed to locate…

  10. Utilisation of Electronic Information Resources By Lecturers in ...

    African Journals Online (AJOL)

    This study assesses the use of information resources, specifically, electronic databases by lecturers/teachers in Universities and Colleges of Education in South Western Nigeria. Information resources are central to teachers' education. It provides lecturers/teachers access to information that enhances research and ...

  11. Euler European Libraries and Electronic Resources in Mathematical Sciences

    CERN Document Server

    The Euler Project. Karlsruhe

    The European Libraries and Electronic Resources (EULER) Project in Mathematical Sciences provides the EulerService site for searching out "mathematical resources such as books, pre-prints, web-pages, abstracts, proceedings, serials, technical reports preprints) and NetLab (for Internet resources), this outstanding engine is capable of simple, full, and refined searches. It also offers a browse option, which responds to entries in the author, keyword, and title fields. Further information about the Project is provided at the EULER homepage.

  12. Building an electronic resource collection a practical guide

    CERN Document Server

    Lee, Stuart D

    2004-01-01

    This practical book guides information professionals step-by-step through building and managing an electronic resource collection. It outlines the range of electronic products currently available in abstracting and indexing, bibliographic, and other services and then describes how to effectively select, evaluate and purchase them.

  13. CDC and ATSDR electronic information resources for health officers.

    Science.gov (United States)

    Friede, A; O'Carroll, P W

    1996-12-01

    This article catalogs some of the Centers for Disease Control and Prevention's (CDC) more important information resource offerings, which make public health information accessible via computer and automated telephone systems and on electronic media (diskette and CD-ROM). We review mechanisms for (1) finding and retrieving CDC reports, (2) querying CDC's numeric data files, (3) transmitting surveillance and other data files to CDC, (4) exchanging electronic mail with CDC staff, and (5) disseminating state and local public health information and data by using CDC tools. Each resource is followed with a section on how to obtain access to these resources.

  14. Organizational matters of competition in electronic educational resources

    Directory of Open Access Journals (Sweden)

    Ирина Карловна Войтович

    2015-12-01

    Full Text Available The article examines the experience of the Udmurt State University in conducting competitions of educational publications and electronic resources. The purpose of such competitions is to provide methodological support to educational process. The main focus is on competition of electronic educational resources. The technology of such contests is discussed through detailed analysis of the main stages of the contest. It is noted that the main task of the preparatory stage of the competition is related to the development of regulations on competition and the definition of criteria for selection of the submitted works. The paper also proposes a system of evaluation criteria of electronic educational resources developed by members of the contest organizing committee and jury members. The article emphasizes the importance of not only the preparatory stages of the competition, but also measures for its completion, aimed at training teachers create quality e-learning resources.

  15. USE OF VIDEO IN MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES

    Directory of Open Access Journals (Sweden)

    Svitlana Denisenko

    2015-10-01

    Full Text Available The widespread introduction of electronic educational resources in the educational process requires the development of a scientific basis for all aspects related to their creation and use. These modern means are designed not just to convey to learners the required course material, but also to create conditions for its most effective study. This is possible in conditions of reasonable approach to the presentation of educational material on the screen. The article is devoted to consideration of the problem of presenting educational material in electronic educational resources. Visuals are powerful didactic tool that enhances the perception and understanding of educational information. Particular attention is paid to the use of such a powerful medium like video. Investigated the role and importance of video in the learning process, their educational opportunities and benefits. Shows types of video and their use in electronic educational resources. Grounded requirements for training videos. The recommendations are given on the use of video in combination with other media in electronic educational resources. Adduced the example a real electronic multimedia educational resource and shows the possibility of using video.

  16. Spin-orbit interaction in quantum dots and quantum wires of correlated electrons - a way to spintronics?

    Energy Technology Data Exchange (ETDEWEB)

    Birkholz, Jens Eiko

    2008-10-06

    We study the influence of the spin-orbit interaction on the electronic transport through quantum dots and quantum wires of correlated electrons. Starting with a one-dimensional infinite continuum model without Coulomb interaction, we analyze the interplay of the spin-orbit interaction, an external magnetic field, and an external potential leading to currents with significant spin-polarization in appropriate parameter regimes. Since lattice models are known to often be superior to continuum models in describing the experimental situation of low-dimensional mesoscopic systems, we construct a lattice model which exhibits the same low-energy physics in terms of energy dispersion and spin expectation values. Confining the lattice to finite length and connecting it to two semi-infinite noninteracting Fermi liquid leads, we calculate the zero temperature linear conductance using the Landauer-Bttiker formalism and show that spin-polarization effects also evolve for the lattice model by adding an adequate potential structure and can be controlled by tuning the overall chemical potential of the system (quantum wire and leads). Next, we allow for a finite Coulomb interaction and use the functional renormalization group (fRG) method to capture correlation effects induced by the Coulomb interaction. The interacting system is thereby transformed into a noninteracting system with renormalized system parameters. For short wires ({proportional_to}100 lattice sites), we show that the energy regime in which spin polarization is found is strongly affected by the Coulomb interaction. For long wires (>1000 lattice sites), we find the power-law suppression of the total linear conductance on low energy scales typical for inhomogeneous Luttinger liquids while the degree of spin polarization stays constant. Considering quantum dots which consist of two lattice sites, we observe the well-known Kondo effect and analyze, how the Kondo temperature is affected by the spin-orbit interaction

  17. High shape recovery Ni–Ti SMA wire produced from electron beam melted ingot

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, A.S. [Instituto Tecnologico de Aeronautica – ITA, 12.228-900, S. J. Campos, SP (Brazil); Instituto Federal de Mato Grosso do Sul – IFMS, 79.331-040, Corumba, MS (Brazil); Tosetti, J.P.V. [Instituto Tecnologico de Aeronautica – ITA, 12.228-900, S. J. Campos, SP (Brazil); Otubo, J., E-mail: jotubo@ita.br [Instituto Tecnologico de Aeronautica – ITA, 12.228-900, S. J. Campos, SP (Brazil)

    2013-11-15

    Highlights: ► It was obtained a remarkable complete shape recovery up to 9% pre-strain. ► Shape recovery higher than 9% was obtained for a pre-strain up to 15%. ► These good results are attributed to a high purity NiTi SMA wire produced from EBM ingot. -- Abstract: Shape recovery of a 2 mm in diameter shape memory alloy (SMA) wire produced from EB melted NiTi ingot is presented. The results indicate complete shape recovery as high as 9% and a shape recovery higher than 9% for a pre-strain between 10 and 15%. These excellent results are attributed to the high purity of starting ingot with carbon content of 0.016 wt%. It was observed no change in reverse martensitic transformation temperature for pre-strain up to 9% and for higher pre-strain there was a 50 °C increase in reverse martensitic transformation peak temperatures indicating some work hardening of the material.

  18. Access to electronic resources by visually impaired people

    Directory of Open Access Journals (Sweden)

    Jenny Craven

    2003-01-01

    Full Text Available Research into access to electronic resources by visually impaired people undertaken by the Centre for Research in Library and Information Management has not only explored the accessibility of websites and levels of awareness in providing websites that adhere to design for all principles, but has sought to enhance understanding of information seeking behaviour of blind and visually impaired people when using digital resources.

  19. Practical guide to electronic resources in the humanities

    CERN Document Server

    Dubnjakovic, Ana

    2010-01-01

    From full-text article databases to digitized collections of primary source materials, newly emerging electronic resources have radically impacted how research in the humanities is conducted and discovered. This book, covering high-quality, up-to-date electronic resources for the humanities, is an easy-to-use annotated guide for the librarian, student, and scholar alike. It covers online databases, indexes, archives, and many other critical tools in key humanities disciplines including philosophy, religion, languages and literature, and performing and visual arts. Succinct overviews of key eme

  20. Electronic Commerce Resource Centers. An Industry--University Partnership.

    Science.gov (United States)

    Gulledge, Thomas R.; Sommer, Rainer; Tarimcilar, M. Murat

    1999-01-01

    Electronic Commerce Resource Centers focus on transferring emerging technologies to small businesses through university/industry partnerships. Successful implementation hinges on a strategic operating plan, creation of measurable value for customers, investment in customer-targeted training, and measurement of performance outputs. (SK)

  1. Providing Access to Electronic Information Resources in Further Education

    Science.gov (United States)

    Banwell, Linda; Ray, Kathryn; Coulson, Graham; Urquhart, Christine; Lonsdale, Ray; Armstrong, Chris; Thomas, Rhian; Spink, Sin; Yeoman, Alison; Fenton, Roger; Rowley, Jennifer

    2004-01-01

    This article aims to provide a baseline for future studies on the provision and support for the use of digital or electronic information services (EIS) in further education. The analysis presented is based on a multi-level model of access, which encompasses access to and availability of information and communication technology (ICT) resources,…

  2. use of electronic resources by graduate students of the department ...

    African Journals Online (AJOL)

    the media (internet, cyber café, Phone and University cafe). 2. There is no significant difference in the level of use of electronic resources between male and female postgraduate students of the department of educational technology and library science in the University of Uyo. 3. There is no significant difference in the of.

  3. Printed And Electronic Resources Utilization By Agricultural Science ...

    African Journals Online (AJOL)

    This paper examines the use of printed and electronic resources by agricultural science students in three Nigerian universities. A two-part questionnaire was designed to elicit necessary information from the respondents selected for the study. One thousand three hundred (1300) respondents from faculties of Agriculture in ...

  4. Adoption and use of electronic information resources by medical ...

    African Journals Online (AJOL)

    This study investigated the adoption and use of electronic information resources by medical science students of the University of Benin. The descriptive survey research design was adopted for the study and 390 students provided the data. Data collected were analysed with descriptive Statistics(Simple percentage and ...

  5. Electronic resources access and usage among the postgraduates of ...

    African Journals Online (AJOL)

    This study investigated electronic resources access and usage among the postgraduates of a Nigerian University of Technology. The Taro Yamane's sample size formula was used to determine sample size of 276 respondents from the total population of the study and systematic random sampling was used to select the ...

  6. Electronic information resource sharing among university libraries in ...

    African Journals Online (AJOL)

    The study explored the state of electronic information resource sharing among university libraries in Southern part of Nigeria, highlighting the prospects and the challenges. The study was an empirical research which adopted the descriptive survey as the design. The questionnaire was used to collect data from the ...

  7. Access to electronic information resources by students of federal ...

    African Journals Online (AJOL)

    The paper discusses access to electronic information resources by students of Federal Colleges of Education in Eha-Amufu and Umunze. Descriptive survey design was used to investigate sample of 526 students. Sampling technique used was a Multi sampling technique. Data for the study were generated using ...

  8. ANALYTICAL REVIEW OF ELECTRONIC RESOURCES FOR THE STUDY OF LATIN

    Directory of Open Access Journals (Sweden)

    Olena Yu. Balalaieva

    2014-04-01

    Full Text Available The article investigates the current state of development of e-learning content in the Latin language. It is noted that the introduction of ICT in the educational space has expanded the possibility of studying Latin, opened access to digital libraries resources, made it possible to use scientific and educational potential and teaching Latin best practices of world's leading universities. A review of foreign and Ukrainian information resources and electronic editions for the study of Latin is given. Much attention was paid to the didactic potential of local and online multimedia courses of Latin, electronic textbooks, workbooks of interactive tests and exercises, various dictionaries and software translators, databases and digital libraries. Based on analysis of the world market of educational services and products the main trends in the development of information resources and electronic books are examined. It was found that multimedia courses with interactive exercises or workbooks with interactive tests, online dictionaries and translators are the most widely represented and demanded. The noticeable lagging of Ukrainian education and computer linguistics in quantitative and qualitative measures in this industry is established. The obvious drawback of existing Ukrainian resources and electronic editions for the study of Latin is their noninteractive nature. The prospects of e-learning content in Latin in Ukraine are outlined.

  9. Use of Internet and Electronic Resources amongst Postgraduate ...

    African Journals Online (AJOL)

    A Nigerian private university is newly venturing into p ostgraduate study programs and has an enrolled postgraduate student population of about a hundred. This study evaluates the postgraduate students' use of library; their information format preference, internet access and electronic resources used in their various ...

  10. The impact of electronic information resource use on research output

    African Journals Online (AJOL)

    The selection of the sample universities was purposive. ... This was demonstrated in the increased number of proposals prepared, submitted and funded, research reports submitted, journal articles published and chapters in books and books published with increased access to and use of electronic information resources.

  11. Technical Communicator: A New Model for the Electronic Resources Librarian?

    Science.gov (United States)

    Hulseberg, Anna

    2016-01-01

    This article explores whether technical communicator is a useful model for electronic resources (ER) librarians. The fields of ER librarianship and technical communication (TC) originated and continue to develop in relation to evolving technologies. A review of the literature reveals four common themes for ER librarianship and TC. While the…

  12. Gender Analysis Of Electronic Information Resource Use: The Case ...

    African Journals Online (AJOL)

    This article is based on an empirical study that examined the association between gender and the use of electronic information resources among postgraduate students at the University of Dar es salaam, Tanzania. The study was conducted in December 2005 and integrated both qualitative and quantitative research ...

  13. Users satisfaction with electronic information resources and services ...

    African Journals Online (AJOL)

    Users satisfaction with electronic information resources and services in A.B.U & UNIBEN MTN Net Libraries. ... Lastly, management of the MTN Net Libraries should conduct user studies annually in order to have feedback from users on how well the library is meeting their information needs. The results of the survey should ...

  14. Skills and training needs for use of electronic information resources ...

    African Journals Online (AJOL)

    The article reports on the findings regarding students' knowledge, skill and training needs in using Electronic Information Resources (EIRs). Data was collected using a questionnaire-based survey administered to 1123 undergraduate students. Probability sampling was used to sample students across the four universities, ...

  15. Think Locally: A Prudent Approach to Electronic Resource Management Systems

    Science.gov (United States)

    Gustafson-Sundell, Nat

    2011-01-01

    A few articles have drawn some amount of attention specifically to the local causes of the success or failure of electronic resource management system (ERMS) implementations. In fact, it seems clear that local conditions will largely determine whether any given ERMS implementation will succeed or fail. This statement might seem obvious, but the…

  16. The wired generation: academic and social outcomes of electronic media use among university students.

    Science.gov (United States)

    Jacobsen, Wade C; Forste, Renata

    2011-05-01

    Little is known about the influence of electronic media use on the academic and social lives of university students. Using time-diary and survey data, we explore the use of various types of electronic media among first-year students. Time-diary results suggest that the majority of students use electronic media to multitask. Robust regression results indicate a negative relationship between the use of various types of electronic media and first-semester grades. In addition, we find a positive association between social-networking-site use, cellular-phone communication, and face-to-face social interaction.

  17. Evaluating the appropriateness of electronic information resources for learning.

    Science.gov (United States)

    Saparova, Dinara; Nolan, Nathanial S

    2016-01-01

    Current US medical students have begun to rely on electronic information repositories-such as UpToDate, AccessMedicine, and Wikipedia-for their pre-clerkship medical education. However, it is unclear whether these resources are appropriate for this level of learning due to factors involving information quality, level of evidence, and the requisite knowledgebase. This study evaluated appropriateness of electronic information resources from a novel perspective: amount of mental effort learners invest in interactions with these resources and effects of the experienced mental effort on learning. Eighteen first-year medical students read about three unstudied diseases in the above-mentioned resources (a total of fifty-four observations). Their eye movement characteristics (i.e., fixation duration, fixation count, visit duration, and task-evoked pupillary response) were recorded and used as psychophysiological indicators of the experienced mental effort. Post reading, students' learning was assessed with multiple-choice tests. Eye metrics and test results constituted quantitative data analyzed according to the repeated Latin square design. Students' perceptions of interacting with the information resources were also collected. Participants' feedback during semi-structured interviews constituted qualitative data and was reviewed, transcribed, and open coded for emergent themes. Compared to AccessMedicine and Wikipedia, UpToDate was associated with significantly higher values of eye metrics, suggesting learners experienced higher mental effort. No statistically significant difference between the amount of mental effort and learning outcomes was found. More so, descriptive statistical analysis of the knowledge test scores suggested similar levels of learning regardless of the information resource used. Judging by the learning outcomes, all three information resources were found appropriate for learning. UpToDate, however, when used alone, may be less appropriate for first

  18. 30 CFR 75.701-4 - Grounding wires; capacity of wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...

  19. E-Resources Management: How We Positioned Our Organization to Implement an Electronic Resources Management System

    Science.gov (United States)

    White, Marilyn; Sanders, Susan

    2009-01-01

    The Information Services Division (ISD) of the National Institute of Standards and Technology (NIST) positioned itself to successfully implement an electronic resources management system. This article highlights the ISD's unique ability to "team" across the organization to realize a common goal, develop leadership qualities in support of…

  20. The electronic conductance of polypyrrole (PPy molecular wires and emergence of Fano resonance phenomena

    Directory of Open Access Journals (Sweden)

    M Mardaani

    2012-06-01

    Full Text Available In this paper, we studied the electronic conductance of a polypyrrole polymer, which is embedded between two semi-infinite simple chains by using Green’s function technique in tight-binding approach. We first reduced the center polymer to a one dimensional chain with renormalized onsite and hopping energies by renormalization method. Then, we calculated the system conductivity as a function of incoming electron energy, polymer length and contact hopping terms. The results showed that by increasing polymer length and decreasing contact hopping energies, the conductance decreases in the gap regions. This means that for larger gaps, the electron tunneling happens with more difficulty. Moreover, at the resonance area, due to the existence of nitrogen atom in the polymer cyclic structure, the Fano resonance will emerge. Furthermore, the polymer can behave like a metallic chain by variation of the value of nitrogen on-site term.

  1. Dirac electrons in graphene-based quantum wires and quantum dots

    Energy Technology Data Exchange (ETDEWEB)

    Peres, N M R; Stauber, T [Centro de Fisica e Departamento de Fisica, Universidade do Minho, P-4710-057, Braga (Portugal); Rodrigues, J N B; Lopes dos Santos, J M B [CFP and Departamento de Fisica, Faculdade de Ciencias Universidade do Porto, P-4169-007, Porto (Portugal)

    2009-08-26

    In this paper we analyse the electronic properties of Dirac electrons in finite-size ribbons and in circular and hexagonal quantum dots. We show that due to the formation of sub-bands in the ribbons it is possible to spatially localize some of the electronic modes using a p-n-p junction. We also show that scattering of confined Dirac electrons in a narrow channel by an infinitely massive wall induces mode mixing, giving a qualitative reason for the fact that an analytical solution to the spectrum of Dirac electrons confined in a square box has not yet been found. A first attempt to solve this problem is presented. We find that only the trivial case k = 0 has a solution that does not require the existence of evanescent modes. We also study the spectrum of quantum dots of graphene in a perpendicular magnetic field. This problem is studied in the Dirac approximation, and its solution requires a numerical method whose details are given. The formation of Landau levels in the dot is discussed. The inclusion of the Coulomb interaction among the electrons is considered at the self-consistent Hartree level, taking into account the interaction with an image charge density necessary to keep the back-gate electrode at zero potential. The effect of a radial confining potential is discussed. The density of states of circular and hexagonal quantum dots, described by the full tight-binding model, is studied using the Lanczos algorithm. This is necessary to access the detailed shape of the density of states close to the Dirac point when one studies large systems. Our study reveals that zero-energy edge states are also present in graphene quantum dots. Our results are relevant for experimental research in graphene nanostructures. The style of writing is pedagogical, in the hope that newcomers to the subject will find this paper a good starting point for their research.

  2. MODEL OF AN ELECTRONIC EDUCATIONAL RESOURCE OF NEW GENERATION

    Directory of Open Access Journals (Sweden)

    Anatoliy V. Loban

    2016-01-01

    Full Text Available The mathematical structure of the modular architecture of an electronic educational resource (EER of new generation, which allows to decompose the process of studying the subjects of the course at a hierarchically ordered set of data (knowledge and procedures for manipulating them, to determine the roles of participants of process of training of and technology the development and use of EOR in the study procrate.

  3. Measurements of high-current electron beams from X pinches and wire array Z pinches.

    Science.gov (United States)

    Shelkovenko, T A; Pikuz, S A; Blesener, I C; McBride, R D; Bell, K S; Hammer, D A; Agafonov, A V; Romanova, V M; Mingaleev, A R

    2008-10-01

    Some issues concerning high-current electron beam transport from the X pinch cross point to the diagnostic system and measurements of the beam current by Faraday cups are discussed. Results of computer simulation of electron beam propagation from the pinch to the Faraday cup give limits for the measured current for beams having different energy spreads. The beam is partially neutralized as it propagates from the X pinch to a diagnostic system, but within a Faraday cup diagnostic, space charge effects can be very important. Experimental results show evidence of such effects.

  4. Electronic instabilities and structural fluctuations in self-assembled atom wires

    NARCIS (Netherlands)

    Snijders, P.C.

    2006-01-01

    One-dimensional (1D) solid state systems can behave drastically different from their higher dimensional counterparts. Increased interactions can produce electronic and/or structural instabilities. In this respect, the following fundamental questions are important for a proper understanding of the

  5. Estimation of changes in nickel and chromium content in nickel-titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study

    Directory of Open Access Journals (Sweden)

    Vandana Kararia

    2015-01-01

    Full Text Available Introduction: The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM study of surface changes and complexometric titration to study compositional change was performed. Materials and Methods: Ten archwires each of group 1-3 M 0.016" NiTi, group 2-JJ 0.016" NiTi, group 3-3 M 0.019" FNx010.025" SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at Χ2000, Χ4000 and Χ6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. Observations and Results: The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0. Conclusion: Extensive and stringent trials are required before certifying any product to be used in Orthodontics.

  6. Estimation of changes in nickel and chromium content in nickel-titanium and stainless steel orthodontic wires used during orthodontic treatment: An analytical and scanning electron microscopic study.

    Science.gov (United States)

    Kararia, Vandana; Jain, Pradeep; Chaudhary, Seema; Kararia, Nitin

    2015-01-01

    The biocompatibility of orthodontic dental alloys has been investigated over the past 20 years, but the results have been inconclusive. The study compares standard 3 M Unitek nickel-titanium (NiTi) and stainless steel archwires with locally available JJ orthodontics wires. Scanning electron microscope (SEM) study of surface changes and complexometric titration to study compositional change was performed. Ten archwires each of group 1-3 M 0.016" NiTi, group 2-JJ 0.016" NiTi, group 3-3 M 0.019" *0.025" SS and group 4-JJ SS contributed a 10 mm piece of wire for analysis prior to insertion in the patient and 6 weeks post insertion. SEM images were recorded at ×2000, ×4000 and ×6000 magnification. The same samples were subjected to complexiometric titration using ethylenediaminetetraacetic acid to gauge the actual change in the composition. The SEM images of all the archwires showed marked changes with deep scratches and grooves and dark pitting corrosion areas post intraoral use. 3M wires showed an uniform criss-cross pattern in as received wires indicating a coating which was absent after intraoral use. There was a significant release of Nickel and Chromium from both group 3 and 4. Group 2 wires released ions significantly more than group 1 (P = 0.0). Extensive and stringent trials are required before certifying any product to be used in Orthodontics.

  7. Journals, Data and Abstracts Make an Integrated Electronic Resource

    Science.gov (United States)

    Boyce, P.

    1996-12-01

    Astronomy now has an integrated, Web-based information resource for research papers, data and bibliographic information. The major scholarly research journals, a comprehensive abstract service and the astronomical data centers are now linked together to provide an information resource which is not available to most other scientific disciplines. As of January, 1997, the Astrophysical Journal joins the ApJ Letters on the Web. Astronomy and Astrophysics Supplements now has a page image version. Elsevier's electronic journal New Astronomy has recently made its appearance. Over forty percent of the new peer-reviewed, astronomical literature is now available electronically. The main Astronomy and Astrophysics journal, the Astronomical Journal and others will be available by 1998, at which point ninety percent of the literature will be available electronically, a figure not approached by any other scientific discipline. With so many different sources, one of the challenges has been to integrate the on-line, peer-reviewed literature into a resource which serves the astronomical community in a unified and coherent manner. Following the lead of the AAS, the major publishers have chosen to rely upon the NASA-supported Astrophysics Data System (ADS) and the astronomical data centers to provide the means by which the various separate journals can interoperate. The data centers and the ADS have developed unique identification codes for journal articles. By adopting the existing standard "bibcodes" and integrating them into their WWW links, each of the major astronomical journals are able to link to the abstracts of most of the referenced articles. Since the ADS also serves as an on-line repository for page images of the past twenty years of the major astronomical journals, the full text of many of the referenced articles are available, too. The articles in the ADS have recently been linked through their references, both forward and backward in time. With the "bibcode" providing

  8. Evaluating increased resource use in fibromyalgia using electronic health records.

    Science.gov (United States)

    Margolis, Jay M; Masters, Elizabeth T; Cappelleri, Joseph C; Smith, David M; Faulkner, Steven

    2016-01-01

    The management of fibromyalgia (FM), a chronic musculoskeletal disease, remains challenging, and patients with FM are often characterized by high health care resource utilization. This study sought to explore potential drivers of all-cause health care resource utilization and other factors associated with high resource use, using a large electronic health records (EHR) database to explore data from patients diagnosed with FM. This was a retrospective analysis of de-identified EHR data from the Humedica database. Adults (≥18 years) with FM were identified based on ≥2 International Classification of Diseases, Ninth Revision codes for FM (729.1) ≥30 days apart between January 1, 2008 and December 31, 2012 and were required to have evidence of ≥12 months continuous care pre- and post-index; first FM diagnosis was the index event; 12-month pre- and post-index reporting periods. Multivariable analysis evaluated relationships between variables and resource utilization. Patients were predominantly female (81.4%), Caucasian (87.7%), with a mean (standard deviation) age of 54.4 (14.8) years. The highest health care resource utilization was observed for the categories of "medication orders" and "physician office visits," with 12-month post-index means of 21.2 (21.5) drug orders/patient and 15.1 (18.1) office visits/patient; the latter accounted for 73.3% of all health care visits. Opioids were the most common prescription medication, 44.3% of all patients. The chance of high resource use was significantly increased ( P FM patients.

  9. Analysis of Human Resources Management Strategy in China Electronic Commerce Enterprises

    Science.gov (United States)

    Shao, Fang

    The paper discussed electronic-commerce's influence on enterprise human resources management, proposed and proved the human resources management strategy which electronic commerce enterprise should adopt from recruitment strategy to training strategy, keeping talent strategy and other ways.

  10. COLLECTIONS OF ELECTRONIC INFORMATION RESOURCES AND THEIR METADESCRIPTIONS AS COMPONENTS OF SCIENTIFIC ELECTRONIC LIBRARY

    Directory of Open Access Journals (Sweden)

    Zoya V. Savchenko

    2011-02-01

    Full Text Available The article presents the results of scientific research components of digital libraries, the main ones being the collection of electronic scientific information resources. An important specific characteristics of collections of scientific information resources, resources of their formation, structure collections, methods of their organization, technology creation, support and use of scientific collections, the role and function of metadata in collections and metadata management technology are represented. On the stage of planning and introduction of scientific e-libraries there can be used results of researches presented in the article, namely: chart of forming of collections of scientific informative resources; stages of planning and development of metadescriptions, and similarly the use of standard the Dublin kernel, creation of metadescriptions.

  11. Electronic Resources and Mission Creep: Reorganizing the Library for the Twenty-First Century

    Science.gov (United States)

    Stachokas, George

    2009-01-01

    The position of electronic resources librarian was created to serve as a specialist in the negotiation of license agreements for electronic resources, but mission creep has added more functions to the routine work of electronic resources such as cataloging, gathering information for collection development, and technical support. As electronic…

  12. Electronic Document Management: A Human Resource Management Case Study

    Directory of Open Access Journals (Sweden)

    Thomas Groenewald

    2004-11-01

    Full Text Available This case study serve as exemplar regarding what can go wrong with the implementation of an electronic document management system. Knowledge agility and knowledge as capital, is outlined against the backdrop of the information society and knowledge economy. The importance of electronic document management and control is sketched thereafter. The literature review is concluded with the impact of human resource management on knowledge agility, which includes references to the learning organisation and complexity theory. The intervention methodology, comprising three phases, follows next. The results of the three phases are presented thereafter. Partial success has been achieved with improving the human efficacy of electronic document management, however the client opted to discontinue the system in use. Opsomming Die gevalle studie dien as voorbeeld van wat kan verkeerd loop met die implementering van ’n elektroniese dokumentbestuur sisteem. Teen die agtergrond van die inligtingsgemeenskap en kennishuishouding word kennissoepelheid en kennis as kapitaal bespreek. Die literatuurstudie word afgesluit met die inpak van menslikehulpbronbestuur op kennissoepelheid, wat ook die verwysings na die leerorganisasie en kompleksietydsteorie insluit. Die metodologie van die intervensie, wat uit drie fases bestaan, volg daarna. Die resultate van die drie fases word vervolgens aangebied. Slegs gedeelte welslae is behaal met die verbetering van die menslike doeltreffendheid ten opsigte van elektroniese dokumentbestuur. Die klient besluit egter om nie voort te gaan om die huidige sisteem te gebruik nie.

  13. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  14. FE modeling of Cu wire bond process and reliability

    NARCIS (Netherlands)

    Yuan, C.A.; Weltevreden, E.R.; Akker, P. van den; Kregting, R.; Vreugd, J. de; Zhang, G.Q.

    2011-01-01

    Copper based wire bonding technology is widely accepted by electronic packaging industry due to the world-wide cost reduction actions (compared to gold wire bond). However, the mechanical characterization of copper wire differs from the gold wire; hence the new wire bond process setting and new bond

  15. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  16. Electronic Safety Resource Tools -- Supporting Hydrogen and Fuel Cell Commercialization

    Energy Technology Data Exchange (ETDEWEB)

    Barilo, Nick F.

    2014-09-29

    The Pacific Northwest National Laboratory (PNNL) Hydrogen Safety Program conducted a planning session in Los Angeles, CA on April 1, 2014 to consider what electronic safety tools would benefit the next phase of hydrogen and fuel cell commercialization. A diverse, 20-person team led by an experienced facilitator considered the question as it applied to the eight most relevant user groups. The results and subsequent evaluation activities revealed several possible resource tools that could greatly benefit users. The tool identified as having the greatest potential for impact is a hydrogen safety portal, which can be the central location for integrating and disseminating safety information (including most of the tools identified in this report). Such a tool can provide credible and reliable information from a trustworthy source. Other impactful tools identified include a codes and standards wizard to guide users through a series of questions relating to application and specific features of the requirements; a scenario-based virtual reality training for first responders; peer networking tools to bring users from focused groups together to discuss and collaborate on hydrogen safety issues; and a focused tool for training inspectors. Table ES.1 provides results of the planning session, including proposed new tools and changes to existing tools.

  17. Resources

    Science.gov (United States)

    ... disease - resources Hemophilia - resources Herpes - resources Incest - resources Incontinence - resources Infertility - resources Interstitial cystitis - resources Kidney disease - resources Leukemia - resources Liver disease - resources Loss ...

  18. Controlling user access to electronic resources without password

    Science.gov (United States)

    Smith, Fred Hewitt

    2015-06-16

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes pre-determining an association of the restricted computer resource and computer-resource-proximal environmental information. Indicia of user-proximal environmental information are received from a user requesting access to the restricted computer resource. Received indicia of user-proximal environmental information are compared to associated computer-resource-proximal environmental information. User access to the restricted computer resource is selectively granted responsive to a favorable comparison in which the user-proximal environmental information is sufficiently similar to the computer-resource proximal environmental information. In at least some embodiments, the process further includes comparing user-supplied biometric measure and comparing it with a predetermined association of at least one biometric measure of an authorized user. Access to the restricted computer resource is granted in response to a favorable comparison.

  19. Utilization of electronic information resources in Ramat Library ...

    African Journals Online (AJOL)

    Data was analysed using descriptive statistics of percentage and frequency counts. ... available in the Ramat Library for the purpose of enhancing learning outcome. Keywords: e-Resources, information resources, utilization, Ramat library ...

  20. Gaseous wire detectors

    Energy Technology Data Exchange (ETDEWEB)

    Va' vra, J.

    1997-08-01

    This article represents a series of three lectures describing topics needed to understand the design of typical gaseous wire detectors used in large high energy physics experiments; including the electrostatic design, drift of electrons in the electric and magnetic field, the avalanche, signal creation, limits on the position accuracy as well as some problems one encounters in practical operations.

  1. Electrochemistry of surface wired cytochrome c and ...

    Indian Academy of Sciences (India)

    Pyrazine unit in the mixed self-assembly promotes the electron transfer in the redox reaction of surface wired Cyt-c. Cyt-c wired on the mixed self-assembly has been used for the amperometric sensing of superoxide. The enzymatically generated superoxide has been successfully detected using the Cyt-c wired electrode.

  2. The Internet School of Medicine: use of electronic resources by medical trainees and the reliability of those resources.

    Science.gov (United States)

    Egle, Jonathan P; Smeenge, David M; Kassem, Kamal M; Mittal, Vijay K

    2015-01-01

    Electronic sources of medical information are plentiful, and numerous studies have demonstrated the use of the Internet by patients and the variable reliability of these sources. Studies have investigated neither the use of web-based resources by residents, nor the reliability of the information available on these websites. A web-based survey was distributed to surgical residents in Michigan and third- and fourth-year medical students at an American allopathic and osteopathic medical school and a Caribbean allopathic school regarding their preferred sources of medical information in various situations. A set of 254 queries simulating those faced by medical trainees on rounds, on a written examination, or during patient care was developed. The top 5 electronic resources cited by the trainees were evaluated for their ability to answer these questions accurately, using standard textbooks as the point of reference. The respondents reported a wide variety of overall preferred resources. Most of the 73 responding medical trainees favored textbooks or board review books for prolonged studying, but electronic resources are frequently used for quick studying, clinical decision-making questions, and medication queries. The most commonly used electronic resources were UpToDate, Google, Medscape, Wikipedia, and Epocrates. UpToDate and Epocrates had the highest percentage of correct answers (47%) and Wikipedia had the lowest (26%). Epocrates also had the highest percentage of wrong answers (30%), whereas Google had the lowest percentage (18%). All resources had a significant number of questions that they were unable to answer. Though hardcopy books have not been completely replaced by electronic resources, more than half of medical students and nearly half of residents prefer web-based sources of information. For quick questions and studying, both groups prefer Internet sources. However, the most commonly used electronic resources fail to answer clinical queries more than half

  3. Bridging the Two Cultures: A Collaborative Approach to Managing Electronic Resources.

    Science.gov (United States)

    Dupuis, John; Ryan, Patti

    2002-01-01

    Highlights an example of cross-discipline collaboration in an academic library and describes a collaborative approach to managing electronic resources that is used at York University (Canada). Explains a model in which a science librarian and a humanities/social science librarian work together to manage electronic resources. (Author/LRW)

  4. Checklist Manifesto for Electronic Resources: Getting Ready for the Fiscal Year and Beyond

    Science.gov (United States)

    England, Lenore; Fu, Li; Miller, Stephen

    2011-01-01

    Organization of electronic resources workflow is critical in the increasingly complicated and complex world of library management. A simple organizational tool that can be readily applied to electronic resources management (ERM) is the use of checklists. Based on the principles discussed in The Checklist Manifesto: How to Get Things Right, the…

  5. Developing Humanities Collections in the Digital Age: Exploring Humanities Faculty Engagement with Electronic and Print Resources

    Science.gov (United States)

    Kachaluba, Sarah Buck; Brady, Jessica Evans; Critten, Jessica

    2014-01-01

    This article is based on quantitative and qualitative research examining humanities scholars' understandings of the advantages and disadvantages of print versus electronic information resources. It explores how humanities' faculty members at Florida State University (FSU) use print and electronic resources, as well as how they perceive these…

  6. Application of the electronic educational resources in the higher educational institution

    Directory of Open Access Journals (Sweden)

    Александр Петрович Колошеин

    2014-12-01

    Full Text Available In article approaches to effective application of electronic educational resources are described. The analysis of methods and forms of education in higher education institution is carried out, the principles of application of the electronic educational resources, adequate to used methods and forms of education are established.

  7. Application of the electronic educational resources in the higher educational institution

    OpenAIRE

    Александр Петрович Колошеин

    2014-01-01

    In article approaches to effective application of electronic educational resources are described. The analysis of methods and forms of education in higher education institution is carried out, the principles of application of the electronic educational resources, adequate to used methods and forms of education are established.

  8. Electronic resource management practical perspectives in a new technical services model

    CERN Document Server

    Elguindi, Anne

    2012-01-01

    A significant shift is taking place in libraries, with the purchase of e-resources accounting for the bulk of materials spending. Electronic Resource Management makes the case that technical services workflows need to make a corresponding shift toward e-centric models and highlights the increasing variety of e-formats that are forcing new developments in the field.Six chapters cover key topics, including: technical services models, both past and emerging; staffing and workflow in electronic resource management; implementation and transformation of electronic resource management systems; the ro

  9. Signal shapes in a TPC wire chamber

    Science.gov (United States)

    Rossegger, S.; Riegler, W.

    2010-11-01

    We study signal shapes in Multi Wire Proportional Chambers (MWPCs) and the influence of the electron distribution around the wire on the ion tail characteristics. Simulations of the ion tail for two different geometries, different voltages and therefore gas gains were performed. These simulations are compared to measurements carried out with the ALICE TPC wire chambers for a Ne/CO 2/N 2 gas mixture, which allows to extract the avalanche spread around the anode wires of the MWPC.

  10. Use of Internet and Electronic Resources amongst Postgraduate ...

    African Journals Online (AJOL)

    Findings indicate that the study group has regular access to the internet , and preferred using free online resources from Google and Wikipedia to institutionally subscribed academic online resources in databases such as HINARI, EBSCO Host, Questia , JSTOR and High Beam.This shows that technology alone cannot help ...

  11. Strategic Planning for Electronic Resources Management: A Case Study at Gustavus Adolphus College

    Science.gov (United States)

    Hulseberg, Anna; Monson, Sarah

    2009-01-01

    Electronic resources, the tools we use to manage them, and the needs and expectations of our users are constantly evolving; at the same time, the roles, responsibilities, and workflow of the library staff who manage e-resources are also in flux. Recognizing a need to be more intentional and proactive about how we manage e-resources, the…

  12. 30 CFR 77.701-3 - Grounding wires; capacity.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity. 77.701-3 Section 77... MINES Grounding § 77.701-3 Grounding wires; capacity. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames, casings, and other metallic enclosures, such grounding wires will be...

  13. EWWW!: Electronic Resources in the Twenty-First Century

    OpenAIRE

    Ogier, Andrea; Brown, Ladd; Bailey, Annette; Stovall, Connie

    2013-01-01

    Initiating necessary change in a modern library environment is quite a difficult task when faced with constantly-evolving technology, limited resources, and low budgets. This paper discusses Virginia Tech’s approach to successful e-resource management when faced with a multitude of challenges. The long-term goal is the development of a proactive information delivery eco-system that will allow staff to anticipate the information and data needs of a single user or user population based on previ...

  14. Wire Array Solar Cells: Fabrication and Photoelectrochemical Studies

    Science.gov (United States)

    Spurgeon, Joshua Michael

    Despite demand for clean energy to reduce our addiction to fossil fuels, the price of these technologies relative to oil and coal has prevented their widespread implementation. Solar energy has enormous potential as a carbon-free resource but is several times the cost of coal-produced electricity, largely because photovoltaics of practical efficiency require high-quality, pure semiconductor materials. To produce current in a planar junction solar cell, an electron or hole generated deep within the material must travel all the way to the junction without recombining. Radial junction, wire array solar cells, however, have the potential to decouple the directions of light absorption and charge-carrier collection so that a semiconductor with a minority-carrier diffusion length shorter than its absorption depth (i.e., a lower quality, potentially cheaper material) can effectively produce current. The axial dimension of the wires is long enough for sufficient optical absorption while the charge-carriers are collected along the shorter radial dimension in a massively parallel array. This thesis explores the wire array solar cell design by developing potentially low-cost fabrication methods and investigating the energy-conversion properties of the arrays in photoelectrochemical cells. The concept was initially investigated with Cd(Se, Te) rod arrays; however, Si was the primary focus of wire array research because its semiconductor properties make low-quality Si an ideal candidate for improvement in a radial geometry. Fabrication routes for Si wire arrays were explored, including the vapor-liquid-solid growth of wires using SiCl4. Uniform, vertically aligned Si wires were demonstrated in a process that permits control of the wire radius, length, and spacing. A technique was developed to transfer these wire arrays into a low-cost, flexible polymer film, and grow multiple subsequent arrays using a single Si(111) substrate. Photoelectrochemical measurements on Si wire array

  15. Controlling user access to electronic resources without password

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Fred Hewitt

    2017-08-22

    Described herein are devices and techniques for remotely controlling user access to a restricted computer resource. The process includes obtaining an image from a communication device of a user. An individual and a landmark are identified within the image. Determinations are made that the individual is the user and that the landmark is a predetermined landmark. Access to a restricted computing resource is granted based on the determining that the individual is the user and that the landmark is the predetermined landmark. Other embodiments are disclosed.

  16. Challenges associated with cataloguing of electronic resources in ...

    African Journals Online (AJOL)

    The aim of the paper is to identify challenges associated with the cataloguing of e resources in some selected university libraries in south –south Nigeria. The descriptive survey design involving the use of questionnaire as the research instrument was adopted. The population comprised of cataloguers in five selected ...

  17. impact of the use of electronic resources on research output

    African Journals Online (AJOL)

    manda

    document delivery since 2000. License to access these resources has been country-wide for most databases. PERI project also includes a training component on ... Sciences (MUHAS). The final sample comprised 222 members of teaching and research staff, selected using purposive and convenience techniques. Findings ...

  18. MODELING OF QUALITY MANAGEMENT SYSTEM FOR ELECTRONIC LEARNING RESOURCES: THE INTEGRATED AND DIFFERENTIATED APPROACHES

    Directory of Open Access Journals (Sweden)

    H. M. Kravtsov

    2012-03-01

    Full Text Available Abstract. Results on modeling of quality management system of electronic information resources on the basis of the analysis of its elements functioning with use of the integrated and differentiated approaches are presented. Application of such model is illustrated on an example of calculation and optimization of parameters of a quality management system at the organization of the co-ordinated work of services of monitoring, an estimation of quality and support of electronic learning resources.

  19. A Study on Developing Evaluation Criteria for Electronic Resources in Evaluation Indicators of Libraries

    Science.gov (United States)

    Noh, Younghee

    2010-01-01

    This study aimed to improve the current state of electronic resource evaluation in libraries. While the use of Web DB, e-book, e-journal, and other e-resources such as CD-ROM, DVD, and micro materials is increasing in libraries, their use is not comprehensively factored into the general evaluation of libraries and may diminish the reliability of…

  20. An Evaluation of Electronic Product Design Education Using Hypermedia-Resourced Learning Environments

    Science.gov (United States)

    Page, Tom; Thorsteinsson, Gisli

    2006-01-01

    The work outlined here provides a comprehensive report and formative observations of the development and implementation of hypermedia resources for learning and teaching used in conjunction with a managed learning environment (MLE). These resources are used to enhance teaching and learning of an electronics module in product design at final year…

  1. Video Killed the Radio Star: Language Students' Use of Electronic Resources-Reading or Viewing?

    Science.gov (United States)

    Kiliçkaya, Ferit

    2016-01-01

    The current study aimed to investigate language students' use of print and electronic resources for their research papers required in research techniques class, focusing on which reading strategies they used while reading these resources. The participants of the study were 90 sophomore students enrolled in the research techniques class offered at…

  2. Problems and future of electronic textbooks and electronic educational resources in technical college

    OpenAIRE

    Kulikov Dmitry

    2016-01-01

    This article describes the problems and prospects of introduction of electronic textbooks in the educational space of technical colleges. Practical recommendations for the maintenance, monitoring, organization and development of electronic textbooks projects.

  3. Electronic information resource use: implications for teaching and library staff

    Directory of Open Access Journals (Sweden)

    Roger Ottewill

    1997-12-01

    Full Text Available Within institutions of higher education, teaching staff and library-based information specialists have tended to occupy separate worlds. Although there has been some contact, in the main this has been partial and intermittent. For first-year students, one consequence of this state of affairs has been the absence of a systematic and co-ordinated strategy for enabling them to acquire, practise and develop information-gathering skills. Teaching staff have seen their role in this respect mainly in terms of issuing students with reading lists containing a mix of books and journal articles, and underlying this approach is the expectation that information specialists will be on hand to provide whatever additional help is needed to access these resources, for example through the provision of introductory talks and one-to-one support sessions. Relatively few teaching staff have incorporated library exercises into their teaching and assessment, or adopted a more creative approach to information gathering by students, such as helping them use bibliographic and other aids to prepare personalized reading lists. Consequently, when students have been required to do this at later stages of their studies, especially in the context of preparing a dissertation, they have not been adequately prepared, and often find it extremely difficult to access and evaluate information resources effectively.

  4. Electronic Information Resources in Undergraduate Education: An Exploratory Study of Opportunities for Student Learning and Independence.

    Science.gov (United States)

    McDowell, Liz

    2002-01-01

    This qualitative interview-based study examines lecturer perspectives on the roles of electronic information resources in undergraduate education. Highlights include electronic academic libraries; changes toward more constructivist approaches to learning; information quality on the Web; plagiarism; information use; information literacy; and…

  5. Where Do Electronic Books Fit in the College Research Arsenal of Resources?

    Science.gov (United States)

    Barbier, Patricia

    2007-01-01

    Student use of electronic books has become an accepted supplement to traditional resources. Student use and satisfaction was monitored through an online course discussion board. Increased use of electronic books indicate this service is an accepted supplement to the print book collection.

  6. End-of-life resource recovery from emerging electronic products

    DEFF Research Database (Denmark)

    Parajuly, Keshav; Habib, Komal; Cimpan, Ciprian

    2016-01-01

    -case scenario, only 47% of the total materials in RVCs are ultimately recycled. While this low material recovery is mainly due to the lower plastic recycling rate, other market realities and the complex material flows in the recycling chain also contribute to it. The study provides a robust methodological...... at a conventional ‘shred-and-separate’ type preprocessing plant in Denmark. A detailed material flow analysis was performed throughout the recycling chain. The results show a mismatch between product design and EoL processing, and the lack of practical implementation of ‘Design for EoL’ thinking. In the best...... approach for assessing the EoL performance based on the knowledge of a product and its complex recycling chain. The lessons learned can be used to support both the design and EoL processing of products with similar features, which carry a high potential for resource recovery, especially at the initial...

  7. Considerable humidity response of a well-aligned SOMS micro-wire flexible sensor by moisture-induced releasing of trapped electrons.

    Science.gov (United States)

    Chan, Kuei-Lin; Yang, Min-Han; Chiu, Hsin-Tien; Lee, Chi-Young

    2017-08-22

    Sandia Octahedral Molecular Sieves micro-wires (SOMS MWs) that exhibit ultra-high response to moisture and a short response time can be produced easily in an environmentally friendly mass production process. They are excellent candidate materials for use in humidity sensors. SOMS MWs were synthesized using niobium pentoxide as a precursor in concentrated sodium hydroxide solution. To fabricate humidity-sensing devices, electrophoresis was utilized to align the SOMS MWs on a polyethylene terephthalate (PET) substrate. The degree of alignment of SOMS MWs can be tuned by controlling the electric field during electrophoresis. Both well-aligned SOMS MWs (S-1.00) and randomly distributed SOMS MWs (S-0.00) exhibit maximum sensitivities to humidity (RRH/RDRY) of almost 104 and 107 respectively, and both exhibit short response times (34 and 38 s) and recovery times (7 and 10 s); these MWs outperform metal oxide ceramic-based materials in sensing humidity. Furthermore, the humidity response of S-1.00 exceeds that of S-0.00 by three orders of magnitude, and this result cannot be explained with reference to the Grotthuss mechanism. Therefore, the moisture-induced carriers from trapped electrons contribute significantly to the humidity response of SOMS MWs. In addition, with outstanding humidity sensing-performance under extreme bending conditions and superior durability after being bent hundreds of times, the well-aligned SOMS MW sensor is a favorable candidate for emerging multifunctional electronic-skin.

  8. Electronic textbooks as a professional resource after dental school.

    Science.gov (United States)

    Bates, Michael L; Strother, Elizabeth A; Brunet, Darlene P; Gallo, John R

    2012-05-01

    In two previous studies of dental students' attitudes about the VitalSource Bookshelf, a digital library of dental textbooks, students expressed negative opinions about owning and reading electronic textbooks. With the assumption that dentists would find the digital textbooks useful for patient care, the authors surveyed recent graduates to determine if their attitude toward the VitalSource Bookshelf had changed. A brief survey was sent to 119 alumni from the classes of 2009 and 2010 of one U.S. dental school. Forty-seven (39.5 percent) completed the questionnaire. Eighteen respondents (48.3 percent) reported using the e-textbooks often or sometimes. The twenty-nine dentists who said they have not used the collection since graduation reported preferring print books or other online sources or having technical problems when downloading the books to a new computer. Only five respondents selected the VitalSource Bookshelf as a preferred source of professional information. Most of the respondents reported preferring to consult colleagues (37.8 percent), the Internet (20 percent), or hardcopy books (17.8 percent) for information. When asked in an open-ended question to state their opinion of the Bookshelf, nineteen (42.2 percent) responded positively, but almost one-third of these only liked the search feature. Six respondents reported that they never use the program. Twenty-two said they have had technical problems with the Bookshelf, including fifteen who have not been able to install it on a new computer. Many of them said they have not followed up with either the dental school or VitalSource support services to overcome this problem. Our study suggests that dentists, similar to dental students, dislike reading electronic textbooks, even with the advantage of searching a topic across more than sixty dental titles.

  9. Obelix Wire Chamber

    CERN Multimedia

    1986-01-01

    Two wire chambers made originally for the R807 Experiment at CERN's Intersecting Storage Rings. In 1986 they were used for the PS 201 experiment (Obelix Experiment) at LEAR, the Low Energy Antiproton Ring. The group of researchers from Turin, using the chambers at that time, changed the acquisition system using for the first time 8 bit (10 bit non linear) analog to digital conversion for incoming signals from the chambers. The acquisition system was controlled by 54 CPU and 80 digital signal processors. The power required for all the electronics was 40 kW. For the period, this system was one of the most powerful on-line apparatus in the world. The Obelix Experiment was closed in 1996. To find more about how a wire chamber works, see the description for object CERN-OBJ-DE-038.

  10. Implementing a tantalum wire mesh to increase the skin dose in low-energy electron irradiation of the chest wall.

    Science.gov (United States)

    Cederbaum, M; Ravkin, A; Rosenblatt, E; Gez, E

    2001-01-01

    Radiation treatment of the post-mastectomy chest wall is performed in our institution by straight-on electron irradiation. The chest-wall thickness is measured and the beam energy is chosen so that the chest wall is treated to therapeutic doses, while sparing the underlying lung tissue. The most commonly chosen energies are 6 and 9 MeV. The skin dose should be 90% of the dose prescribed to the chest wall, which is higher than can be achieved with 6- and 9-MeV beams because of the low surface dose. The addition of a bolus slab during part of the treatment can correct for this; however, the added depth means that a higher energy has to be chosen, which will increase the lung dose (the higher the electron energy, the slower the falloff of the electron depth-dose curve). A mesh of a high-Z material above the skin gives rise to obliquely scattered and low-energy electrons that effectively spoil the buildup zone. Dosimetric measurements of a Tantalum (Ta) mesh were performed using a dose scanner in a water tank and a film inserted in a humanoid phantom during a simulated treatment. Measurements were also done for the clinically relevant cases of oblique beam incidence and with the mesh placed 1 cm above the surface. The measurements demonstrate the spoiling of the buildup zone, while having only a moderate influence on the dose distribution beyond the dose maximum. The mesh also changes the absolute dose. In a fractionated regime, the first part of the treatment would be without the mesh, adding it only during the latter fractions. The total dose distribution gives 90% to the skin, while leaving the depth-dose characteristics beyond the dose maximum virtually unchanged.

  11. Cavity Mode Related Wire Breaking of the SPS Wire Scanners and Loss Measurements of Wire Materials

    CERN Document Server

    Caspers, Friedhelm; Jensen, E; Koopman, J; Malo, J F; Roncarolo, F

    2003-01-01

    During the SPS high intensity run 2002 with LHC type beam, the breaking of several of the carbon wires in the wire scanners has been observed in their parking position. The observation of large changes in the wire resistivity and thermionic electron emission clearly indicated strong RF heating that was depending on the bunch length. A subsequent analysis in the laboratory, simulating the beam by two probe antennas or by a powered stretched wire, showed two main problems: i) the housing of the wire scanner acts as a cavity with a mode spectrum starting around 350 MHz and high impedance values around 700 MHz; ii) the carbon wire used so far appears to be an excellent RF absorber and thus dissipates a significant part of the beam-induced power. Different wire materials are compared with the classical cavity mode technique for the determination of the complex permittivity in the range of 2-4 GHz. As a resonator a rectangular TE_01n type device is utilized.

  12. Cavity mode related wire breaking of the SPS Wire Scanners and loss measurements of wire materials

    CERN Document Server

    Roncarolo, Federico

    2003-01-01

    During the SPS high intensity run 2002 with LHC type beam, the breaking of several of the carbon wires in the wire scanners has been observed in their parking position. The observation of large changes in the wire resistivity and thermionic electron emission clearly indicated strong RF heating that was depending on the bunch length. A subsequent analysis in the laboratory, simulating the beam by two probe antennas or by a powered stretched wire, showed two main problems: i) the housing of the wire scanner acts as a cavity with a mode spectrum starting around 350MHz and high impedance values around 700 MHz; ii) the carbon wire used so far appears to be an excellent RF absorber and thus dissipates a significant part of the beam-induced power. Different wire materials are compared with the classical cavity mode technique for the determination of the complex permittivity in the range of 2-4 GHz. As a resonator a rectangular TE01n type device is utilized.

  13. Transmission electron microscopy and photoluminescence characterization of InGaAs strained quantum wires on GaAs vicinal (110) substrates

    CERN Document Server

    Shim, B R; Ota, T; Kobayashi, K; Maehashi, K; Nakashima, H; Lee, S Y

    1999-01-01

    We have used transmission electron microscopy (TEM) and photoluminescence (PL) to study InGaAs/AlGaAs strained quantum wires (QWRs) grown by molecular beam epitaxy (MBE) on GaAs vicinal (110) substrates. The cross-sectional TEM image reveals that InGaAs QWRs structures are naturally formed on AlGaAs giant steps. In the plan-view TEM images, the fringe pattern in the giant-step region is observed for In sub x Ga sub 1 sub - sub x As layers with x<= 0.4 We measured the separation of the fringe in the plan-view TEM images and compared the result with the calculated fringe separation. From this result, we conclude that the fringes observed in the plan-view TEM images are moire fringes. PL spectra of the InGaAs QWRs samples reveal 80-meV shifts to lower energy with respect to the spectrum of a quantum well (QWL) grown on a (001) substrate under the same conditions. We also measured the polarization anisotropy of the PL spectra from the QWRs. The PL peak shifts systematically toward higher energy with decreasing...

  14. Hierarchical structures in cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2013-01-01

    The microstructure and crystallography of drawn pearlitic steel wires have been quantified by a number of electron microscopy techniques including scanning electron microscopy, transmission electron microscopy, electron backscatter diffraction and nanobeam diffraction, with focus on the change...

  15. Analytical Study of Usage of Electronic Information Resources at Pharmacopoeial Libraries in India

    Directory of Open Access Journals (Sweden)

    Sunil Tyagi

    2014-02-01

    Full Text Available The objective of this study is to know the rate and purpose of the use of e-resource by the scientists at pharmacopoeial libraries in India. Among other things, this study examined the preferences of the scientists toward printed books and journals, electronic information resources, and pattern of using e-resources. Non-probability sampling specially accidental and purposive technique was applied in the collection of primary data through administration of user questionnaire. The sample respondents chosen for the study consists of principle scientific officer, senior scientific officer, scientific officer, and scientific assistant of different division of the laboratories, namely, research and development, pharmaceutical chemistry, pharmacovigilance, pharmacology, pharmacogonosy, and microbiology. The findings of the study reveal the personal experiences and perceptions they have had on practice and research activity using e-resource. The major findings indicate that of the total anticipated participants, 78% indicated that they perceived the ability to use computer for electronic information resources. The data analysis shows that all the scientists belonging to the pharmacopoeial libraries used electronic information resources to address issues relating to drug indexes and compendia, monographs, drugs obtained through online databases, e-journals, and the Internet sources—especially polices by regulatory agencies, contacts, drug promotional literature, and standards.

  16. Connecting knowledge resources to the veterinary electronic health record: opportunities for learning at point of care.

    Science.gov (United States)

    Alpi, Kristine M; Burnett, Heidi A; Bryant, Sheila J; Anderson, Katherine M

    2011-01-01

    Electronic health records (EHRs) provide clinical learning opportunities through quick and contextual linkage of patient signalment, symptom, and diagnosis data with knowledge resources covering tests, drugs, conditions, procedures, and client instructions. This paper introduces the EHR standards for linkage and the partners-practitioners, content publishers, and software developers-necessary to leverage this possibility in veterinary medicine. The efforts of the American Animal Hospital Association (AAHA) Electronic Health Records Task Force to partner with veterinary practice management systems to improve the use of controlled vocabulary is a first step in the development of standards for sharing knowledge at the point of care. The Veterinary Medical Libraries Section (VMLS) of the Medical Library Association's Task Force on Connecting the Veterinary Health Record to Information Resources compiled a list of resources of potential use at point of care. Resource details were drawn from product Web sites and organized by a metric used to evaluate medical point-of-care resources. Additional information was gathered from questions sent by e-mail and follow-up interviews with two practitioners, a hospital network, two software developers, and three publishers. Veterinarians with electronic records use a variety of information resources that are not linked to their software. Systems lack the infrastructure to use the Infobutton standard that has been gaining popularity in human EHRs. While some veterinary knowledge resources are digital, publisher sites and responses do not indicate a Web-based linkage of veterinary resources with EHRs. In order to facilitate lifelong learning and evidence-based practice, veterinarians and educators of future practitioners must demonstrate to veterinary practice software developers and publishers a clinically-based need to connect knowledge resources to veterinary EHRs.

  17. Elektronik Bilgi Kaynaklarının Seçimi / Selection of Electronic Information Resources

    Directory of Open Access Journals (Sweden)

    Pınar Al

    2003-04-01

    Full Text Available For many years, library users have used only from the printed media in order to get the information that they have needed. Today with the widespread use of the Web and the addition of electronic information resources to library collections, the use of information in the electronic environment as well as in printed media is started to be used. In time, such types of information resources as, electronic journals, electronic books, electronic encyclopedias, electronic dictionaries and electronic theses have been added to library collections. In this study, selection criteria that can be used for electronic information resources are discussed and suggestions are provided for libraries that try to select electronic information resources for their collections.

  18. Correlated atomic wires on substrates. II. Application to Hubbard wires

    Science.gov (United States)

    Abdelwahab, Anas; Jeckelmann, Eric; Hohenadler, Martin

    2017-07-01

    In the first part of our theoretical study of correlated atomic wires on substrates, we introduced lattice models for a one-dimensional quantum wire on a three-dimensional substrate and their approximation by quasi-one-dimensional effective ladder models [Abdelwahab et al., preceding paper, Phys. Rev. B 96, 035445 (2017), 10.1103/PhysRevB.96.035445]. In this second part, we apply this approach to the case of a correlated wire with a Hubbard-type electron-electron repulsion deposited on an insulating substrate. The ground-state and spectral properties are investigated numerically using the density-matrix renormalization group method and quantum Monte Carlo simulations. As a function of the model parameters, we observe various phases with quasi-one-dimensional low-energy excitations localized in the wire, namely, paramagnetic Mott insulators, Luttinger liquids, and spin-1 /2 Heisenberg chains. The validity of the effective ladder models is assessed for selected parameters by studying the dependence of results on the number of legs and comparing to the full three-dimensional model. We find that narrow ladder models accurately reproduce the quasi-one-dimensional excitations of the full three-dimensional model but predict only qualitatively whether excitations are localized around the wire or delocalized in the three-dimensional substrate.

  19. Considering Point-of-Care Electronic Medical Resources in Lieu of Traditional Textbooks for Medical Education.

    Science.gov (United States)

    Hale, LaDonna S; Wallace, Michelle M; Adams, Courtney R; Kaufman, Michelle L; Snyder, Courtney L

    2015-09-01

    Selecting resources to support didactic courses is a critical decision, and the advantages and disadvantages must be carefully considered. During clinical rotations, students not only need to possess strong background knowledge but also are expected to be proficient with the same evidence-based POC resources used by clinicians. Students place high value on “real world” learning and therefore may place more value on POC resources that they know practicing clinicians use as compared with medical textbooks. The condensed nature of PA education requires students to develop background knowledge and information literacy skills over a short period. One way to build that knowledge and those skills simultaneously is to use POC resources in lieu of traditional medical textbooks during didactic training. Electronic POC resources offer several advantages over traditional textbooks and should be considered as viable options in PA education.

  20. 30 CFR 77.705 - Guy wires; grounding.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Guy wires; grounding. 77.705 Section 77.705... MANDATORY SAFETY STANDARDS, SURFACE COAL MINES AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Grounding § 77.705 Guy wires; grounding. Guy wires from poles supporting high-voltage transmission lines shall be...

  1. Awareness and use of electronic resources at a university campus in ...

    African Journals Online (AJOL)

    This study looks into the use of electronic resources by the faculty members of College of Technology Education, Kumasi of the University of Education, Winneba, Ghana. Sixty-two copies of a questionnaire were sent to the entire faculty and 31 were returned which gave a response rate of 50%. The responses showed very ...

  2. Localising versus standardising electronic human resource management: complexities and tensions between HRM and IT departments

    NARCIS (Netherlands)

    Tate, Mary; Furtmueller-Ettinger, Elfriede; Wilderom, Celeste P.M.

    2013-01-01

    In this paper, we provide an analysis of the complexities involved during global e-HRM (Electronic Human Resource Management) implementation. We present findings from a case study on the challenge of global integration versus local responsiveness of e-HRM systems. We take a local site lens,

  3. Automatic wire twister.

    Science.gov (United States)

    Smith, J F; Rodeheaver, G T; Thacker, J G; Morgan, R F; Chang, D E; Fariss, B L; Edlich, R F

    1988-06-01

    This automatic wire twister used in surgery consists of a 6-inch needle holder attached to a twisting mechanism. The major advantage of this device is that it twists wires significantly more rapidly than the conventional manual techniques. Testing has found that the ultimate force required to disrupt the wires twisted by either the automatic wire twister or manual techniques did not differ significantly and was directly related to the number of twists. The automatic wire twister reduces the time needed for wire twisting without altering the security of the twisted wire.

  4. Stretched Wire Mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, Gordon; /SLAC

    2005-09-06

    Stretched wires are beginning to play an important role in the alignment of accelerators and synchrotron light sources. Stretched wires are proposed for the alignment of the 130 meter long LCLS undulator. Wire position technology has reached sub-micron resolution yet analyses of perturbations to wire straightness are hard to find. This paper considers possible deviations of stretched wire from the simple 2-dimensional catenary form.

  5. Highly stretchable wrinkled gold thin film wires

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joshua, E-mail: joshuk7@uci.edu; Park, Sun-Jun; Nguyen, Thao [Department of Chemical Engineering and Materials Science, University of California, Irvine, California 92697 (United States); Chu, Michael [Department of Biomedical Engineering, University of California, Irvine, California 92697 (United States); Pegan, Jonathan D. [Department of Materials and Manufacturing Technology, University of California, Irvine, California 92697 (United States); Khine, Michelle, E-mail: mkhine@uci.edu [Department of Chemical Engineering and Materials Science, University of California, Irvine, California 92697 (United States); Department of Biomedical Engineering, University of California, Irvine, California 92697 (United States)

    2016-02-08

    With the growing prominence of wearable electronic technology, there is a need to improve the mechanical reliability of electronics for more demanding applications. Conductive wires represent a vital component present in all electronics. Unlike traditional planar and rigid electronics, these new wearable electrical components must conform to curvilinear surfaces, stretch with the body, and remain unobtrusive and low profile. In this paper, the piezoresistive response of shrink induced wrinkled gold thin films under strain demonstrates robust conductive performance in excess of 200% strain. Importantly, the wrinkled metallic thin films displayed negligible change in resistance of up to 100% strain. The wrinkled metallic wires exhibited consistent performance after repetitive strain. Importantly, these wrinkled thin films are inexpensive to fabricate and are compatible with roll to roll manufacturing processes. We propose that these wrinkled metal thin film wires are an attractive alternative to conventional wires for wearable applications.

  6. Perceived Effect of Accessibility and Utilization of Electronic Resources on Productivity of Academic Staff in Selected Nigerian Universities

    Directory of Open Access Journals (Sweden)

    Okon E. Ani

    2015-10-01

    Full Text Available Access to information is vital for efficient research at universities. Electronic resources provide new platforms for information to aid in conducting research at universities. This study explores the perceived effect of accessibility and utilization of electronic resources on research productivity at Nigerian universities. A quantitative research approach was adopted for the study with a survey as research method. Data were collected for the study with a self-reporting questionnaire. Regression analysis in the study revealed that accessibility and use of electronic resources had a significant perceived positive effect on research productivity at the surveyed Nigerian universities. However, there was no significant perceived effect of accessibility and use of electronic resources by discipline on research productivity in the survey. In terms of gender, it was found that there was no significant perceived effect of accessibility and use of electronic resources by gender on research productivity among respondents at the surveyed Nigerian universities. Based on these findings, it is recommended that effective development of digital libraries in Nigerian universities would ameliorate the problems of accessibility and utilization of electronic resources by academic staff in research. Furthermore, the Nigerian university libraries should develop an electronic collection development policy to enhance equitable access and use of electronic resources at Nigerian universities. Policy for sustainable digitization of relevant library materials should be evolved to support digital libraries effectively for efficient accessibility and utilization of electronic resources.

  7. Weyl fermions in cylindrical wires

    Science.gov (United States)

    Erementchouk, Mikhail; Mazumder, Pinaki

    2018-01-01

    The key feature of Weyl semimetals (WSMs) is the presence of topologically protected Dirac cones in a three-dimensional material. We consider the effect of restricting geometry on the spectrum of excitations in WSMs using as a model a cylindrical WSM wire. For the full manifold of hard boundary conditions, we derive the general form of the dispersion equation relating the energy of the excitations and their momentum along the wire. We show that only the special class of boundary conditions, corresponding to decoupled helicities or, equivalently, to pinned directions of the electron spin on the surface, support massless excitations. For a general boundary condition, these excitations acquire mass inversely proportional to the radius of the wire. This demonstrates that boundary phenomena may play a crucial role in formation of excitations in WSM based structures.

  8. Library Electronic Resource Sharing Among Liberal Arts Colleges: ACS Palladian Alliance Project

    Directory of Open Access Journals (Sweden)

    Wenxian Zhang

    1997-03-01

    Full Text Available 無Effective electronic resource sharing is critical to library information services of the 1990s. Explosion of data and increased cost of information force libraries to work together, and technological advancements present the library service profession a platform for resource sharing. The Palladian Alliance Project of the Associated Colleges of the South is designed to provides ACS member institutions an effective means to enhance information access for their faculty and students, and achieve significant cost containment in the years to come.

  9. A Vibrating Wire System For Quadrupole Fiducialization

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Zachary

    2010-12-13

    A vibrating wire system is being developed to fiducialize the quadrupoles between undulator segments in the LCLS. This note provides a detailed analysis of the system. The LCLS will have quadrupoles between the undulator segments to keep the electron beam focused. If the quadrupoles are not centered on the beam axis, the beam will receive transverse kicks, causing it to deviate from the undulator axis. Beam based alignment will be used to move the quadrupoles onto a straight line, but an initial, conventional alignment must place the quadrupole centers on a straight line to 100 {micro}m. In the fiducialization step of the initial alignment, the position of the center of the quadrupole is measured relative to tooling balls on the outside of the quadrupole. The alignment crews then use the tooling balls to place the magnet in the tunnel. The required error on the location of the quadrupole center relative to the tooling balls must be less than 25 {micro}m. In this note, we analyze a system under construction for the quadrupole fiducialization. The system uses the vibrating wire technique to position a wire onto the quadrupole magnetic axis. The wire position is then related to tooling balls using wire position detectors. The tooling balls on the wire position detectors are finally related to tooling balls on the quadrupole to perform the fiducialization. The total 25 {micro}m fiducialization error must be divided between these three steps. The wire must be positioned onto the quadrupole magnetic axis to within 10 {micro}m, the wire position must be measured relative to tooling balls on the wire position detectors to within 15 {micro}m, and tooling balls on the wire position detectors must be related to tooling balls on the quadrupole to within 10 {micro}m. The techniques used in these three steps will be discussed. The note begins by discussing various quadrupole fiducialization techniques used in the past and discusses why the vibrating wire technique is our method

  10. Improved lithium cyclability and storage in mesoporous SnO2 electronically wired with very low concentrations (≤1 %) of reduced graphene oxide.

    Science.gov (United States)

    Shiva, Konda; Rajendra, H B; Subrahmanyam, K S; Bhattacharyya, Aninda J; Rao, C N R

    2012-04-10

    On the wire: Mesoporous tin dioxide (SnO(2)) wired with very low amounts (≤1 %) of reduced graphene oxide (rGO) exhibits a remarkable improvement in lithium-ion battery performance over bare mesoporous or solid nanoparticles of SnO(2). Reversible lithium intercalation into SnO(2)/SnO over several cycles was demonstrated in addition to conventional reversible lithium storage by an alloying reaction. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. ELECTRONIC EDUCATIONAL RESOURCES FOR ONLINE SUPPORT OF MODERN CHEMISTRY CLASSES IN SPECIALIZED SCHOOL

    OpenAIRE

    Maria D. Tukalo

    2013-01-01

    This article contains material of some modern electronic educational resources that can be used via the Internet to support the modern chemistry classes in specialized school. It was drawn attention to the educational chemical experiments as means of knowledge; simulated key motivational characteristics to enhance students interest for learning subjects, their cognitive and practical activity in the formation of self-reliance and self-creative; commented forecasts for creating of conditions t...

  12. A systematic review of portable electronic technology for health education in resource-limited settings.

    Science.gov (United States)

    McHenry, Megan S; Fischer, Lydia J; Chun, Yeona; Vreeman, Rachel C

    2017-08-01

    The objective of this study is to conduct a systematic review of the literature of how portable electronic technologies with offline functionality are perceived and used to provide health education in resource-limited settings. Three reviewers evaluated articles and performed a bibliography search to identify studies describing health education delivered by portable electronic device with offline functionality in low- or middle-income countries. Data extracted included: study population; study design and type of analysis; type of technology used; method of use; setting of technology use; impact on caregivers, patients, or overall health outcomes; and reported limitations. Searches yielded 5514 unique titles. Out of 75 critically reviewed full-text articles, 10 met inclusion criteria. Study locations included Botswana, Peru, Kenya, Thailand, Nigeria, India, Ghana, and Tanzania. Topics addressed included: development of healthcare worker training modules, clinical decision support tools, patient education tools, perceptions and usability of portable electronic technology, and comparisons of technologies and/or mobile applications. Studies primarily looked at the assessment of developed educational modules on trainee health knowledge, perceptions and usability of technology, and comparisons of technologies. Overall, studies reported positive results for portable electronic device-based health education, frequently reporting increased provider/patient knowledge, improved patient outcomes in both quality of care and management, increased provider comfort level with technology, and an environment characterized by increased levels of technology-based, informal learning situations. Negative assessments included high investment costs, lack of technical support, and fear of device theft. While the research is limited, portable electronic educational resources present promising avenues to increase access to effective health education in resource-limited settings, contingent

  13. Potential resource and toxicity impacts from metals in waste electronic devices.

    Science.gov (United States)

    Woo, Seung H; Lee, Dae Sung; Lim, Seong-Rin

    2016-04-01

    As a result of the continuous release of new electronic devices, existing electronic devices are quickly made obsolete and rapidly become electronic waste (e-waste). Because e-waste contains a variety of metals, information about those metals with the potential for substantial environmental impact should be provided to manufacturers, recyclers, and disposers to proactively reduce this impact. This study assesses the resource and toxicity (i.e., cancer, noncancer, and ecotoxicity) potentials of various heavy metals commonly found in e-waste from laptop computers, liquid-crystal display (LCD) monitors, LCD TVs, plasma TVs, color cathode ray tube (CRT) TVs, and cell phones and then evaluates such potentials using life cycle impact-based methods. Resource potentials derive primarily from Cu, Sb, Ag, and Pb. Toxicity potentials derive primarily from Pb, Ni, and Hg for cancer toxicity; from Pb, Hg, Zn, and As for noncancer toxicity; and from Cu, Pb, Hg, and Zn for ecotoxicity. Therefore, managing these heavy metals should be a high priority in the design, recycling, and disposal stages of electronic devices. © 2015 SETAC.

  14. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  15. Opening a Can of wERMS: Texas A&M University's Experiences in Implementing Two Electronic Resource Management Systems

    Science.gov (United States)

    Hartnett, Eric; Price, Apryl; Smith, Jane; Barrett, Michael

    2010-01-01

    Over the past few years, Texas A&M University (TAMU) has searched for a way to administer its electronic subscriptions as well as the electronic subscriptions shared among the TAMU System. In this article, we address our attempts to implement an effective electronic resource management system (ERMS), both for subscriptions on the main campus…

  16. Chemically etched modulation in wire radius for wire array Z-pinch perturbation studies

    Science.gov (United States)

    Jones, B.; Deeney, C.; McKenney, J. L.; Garrity, J. E.; Lobley, D. K.; Martin, K. L.; Griego, A. E.; Ramacciotti, J. P.; Bland, S. N.; Lebedev, S. V.; Bott, S. C.; Ampleford, D. J.; Palmer, J. B. A.; Rapley, J.; Hall, G.

    2004-11-01

    A technique for manufacturing wires with imposed modulation in radius with axial wavelengths as short as 1 mm is presented. Extruded aluminum 5056 with 15 μm diameter was masked and chemically etched to reduce the radius by ˜20% in selected regions. Characterized by scanning electron microscopy, the modulation in radius is a step function with a ˜10 μm wide conical transition between thick and thin segments, with some pitting in etched regions. Techniques for mounting and aligning these wires in arrays for fast z-pinch experiments will be discussed. Axially mass-modulated wire arrays of this type will allow the study of seeded Rayleigh-Taylor instabilities in z pinches, corona formation, wire initiation with varying current density in the wire core, and correlation of perturbations between adjacent wires. This tool will support magnetohydrodynamics code validation in complex three-dimensional geometries, and perhaps x-ray pulse shaping.

  17. Absorbed Dose Distributions in Small Copper Wire Insulation due to Multiple-Sided Irradiations by 0.4 MeV Electrons

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.; Pedersen, Walther Batsberg

    1979-01-01

    . and insulation thicknesses between 0.4 and 0.8 mm. The plastic dosimeter simulating polyethylene insulations was a thin radiochromic polyvinyl butyral film wrapped several times around the copper wire, such that when unwrapped and analyzed optically on a scanning microspectrophotometer, high-resolution radial...

  18. Model of e-learning with electronic educational resources of new generation

    Directory of Open Access Journals (Sweden)

    A. V. Loban

    2017-01-01

    Full Text Available Purpose of the article: improving of scientific and methodical base of the theory of the е-learning of variability. Methods used: conceptual and logical modeling of the е-learning of variability process with electronic educational resource of new generation and system analysis of the interconnection of the studied subject area, methods, didactics approaches and information and communication technologies means. Results: the formalization complex model of the е-learning of variability with electronic educational resource of new generation is developed, conditionally decomposed into three basic components: the formalization model of the course in the form of the thesaurusclassifier (“Author of e-resource”, the model of learning as management (“Coordination. Consultation. Control”, the learning model with the thesaurus-classifier (“Student”. Model “Author of e-resource” allows the student to achieve completeness, high degree of didactic elaboration and structuring of the studied material in triples of variants: modules of education information, practical task and control tasks; the result of the student’s (author’s of e-resource activity is the thesaurus-classifier. Model of learning as management is based on the principle of personal orientation of learning in computer environment and determines the logic of interaction between the lecturer and the student when determining the triple of variants individually for each student; organization of a dialogue between the lecturer and the student for consulting purposes; personal control of the student’s success (report generation and iterative search for the concept of the class assignment in the thesaurus-classifier before acquiring the required level of training. Model “Student” makes it possible to concretize the learning tasks in relation to the personality of the student and to the training level achieved; the assumption of the lecturer about the level of training of a

  19. Laser Wire Stripper

    Science.gov (United States)

    1983-01-01

    NASA-developed space shuttle technology is used in a laser wire stripper designed by Raytheon Company. Laser beams cut through insulation on a wire without damaging conductive metal, because laser radiation that melts plastic insulation is reflected by the metal. The laser process is fast, clean, precise and repeatable. It eliminates quality control problems and the expense of rejected wiring.

  20. Theoretical Aspects of the Use of Electronic Educational Resources in Professional Activity of Future Teachers of Technology

    Directory of Open Access Journals (Sweden)

    Iryna Smyrnova

    2017-06-01

    Full Text Available In this paper, we tried to determine the requirements for ESM, to study theoretical aspects of electronic educational resources in the professional activity of future teachers. The results created by the introduction of our course “Methodology development and use of electronic educational resources” for future teachers of technology ITOS in the process of professional specialty “Technology” in the educational process of higher educational institutions of Ukraine. The article states the rapid development of computer hardware and computer software, IT technologies have an opportunity to significantly develop the field of electronic educational resources. This is due to the emergence of global networks where information technologies have become the second paradigm, which is based on the current understanding of electronic educational resources. We determined that the dynamism inherent in information technology, enabling expectations of new approaches that will change the meaning of electronic educational resources.

  1. Postgraduate medical students' acceptance and understanding of scientific information databases and electronic resources.

    Science.gov (United States)

    Azami, Mohammad; Khajouei, Reza; Rakhshani, Safiyeh

    2016-03-01

    The significance and validity of web-based scientific databases are increasing dramatically in the scientific community. Moreover, a great number of students use these resources without having sufficient and accurate knowledge and understanding. In order for students to use these databases and electronic resources optimally, identifying the factors that affect the understanding and acceptance of these resources seems necessary. The aim of this study was to determine postgraduate medical students' acceptance and understanding of these resources. This cross-sectional study was conducted on 311 postgraduate medical students from Kerman University of Medical Science (KMU) in 2013. Data were collected using a researcher-made questionnaire, and the data were analyzed using SPSS. In order to design the model (i.e., the interaction between study variables and to determine the relationships between them in an integrated pattern), LISREL version 8.7 and a structural equation model were used. Descriptive statistics and t-tests also were used in data analysis. The results showed that the average components of the perception of usefulness, perception of ease of use, attitude towards use, decision to use, using to perform duties, and using to increase knowledge were 4.31, 4.14, 4.24, 16.27, 20.85, and 16.13 respectively. Accordingly, the average of all these indicators was significantly higher than the assumed amount (p < 0.01). Moreover, the results obtained from factor analysis and the structural equation model indicated that the model of the present study fit the data perfectly. Based on the findings of this study, the more these databases are considered useful and easy to use, the more they are used. Therefore, designers of databases and electronic resources can design systems that are both useful and easy to learn by considering the components of the research model.

  2. Flicking-wire drag tensioner

    Science.gov (United States)

    Dassele, M. A.; Fairall, H.

    1978-01-01

    Wire-drag system improves wire profile and applies consistent drag to wire. Wire drag is continuously adjustable from zero drag to tensile strength of wire. No-sag wire drag is easier to thread than former system and requires minimal downtime for cleaning and maintenance.

  3. Review of material recovery from used electric and electronic equipment-alternative options for resource conservation.

    Science.gov (United States)

    Friege, Henning

    2012-09-01

    For waste from electric and electronic equipment, the WEEE Directive stipulates the separate collection of electric and electronic waste. As to new electric and electronic devices, the Restriction of Hazardous Substances (RoHS) Directive bans the use of certain chemicals dangerous for man and environment. From the implementation of the WEEE directive, many unsolved problems have been documented: poor collection success, emission of dangerous substances during collection and recycling, irretrievable loss of valuable metals among others. As to RoHS, data from the literature show a satisfying success. The problems identified in the process can be reduced to some basic dilemmas at the borders between waste management, product policy and chemical safety. The objectives of the WEEE Directive and the specific targets for use and recycling of appliances are not consistent. There is no focus on scarce resources. Extended producer responsibility is not sufficient to guarantee sustainable waste management. Waste management reaches its limits due to problems of implementation but also due to physical laws. A holistic approach is necessary looking at all branch points and sinks in the stream of used products and waste from electric and electronic equipment. This may be done with respect to the general rules for sustainable management of material streams covering the three dimensions of sustainable policy. The relationships between the players in the field of electric and electronic devices have to be taken into account. Most of the problems identified in the implementation process will not be solved by the current amendment of the WEEE Directive.

  4. Time and space resolved measurement of the electron temperature, mass density and ionization state in the ablation plasma between two exploding Al wires

    Energy Technology Data Exchange (ETDEWEB)

    Knapp, P. F.; Pikuz, S. A.; Shelkovenko, T. A.; Hammer, D. A. [Laboratory of Plasma Studies, Cornell University, 439 Rhodes Hall, Ithaca, New York 14853 (United States); Hansen, S. B. [Sandia National Laboratories, Albuquerque, New Mexico 87185 (United States)

    2012-05-15

    We have determined the properties of plasma around and between two exploding wires using high-resolution x-ray absorption spectroscopy. Plasma densities and temperatures ranging from Greater-Than-Or-Equivalent-To 0.1g/cm{sup 3} and a few eV to less than 0.01 g/cm{sup 3} and 30 eV have been measured in experiments at Cornell University with two 40 {mu}m aluminum (Al) wires spaced 1 mm apart driven by {approx}150 kA peak current pulses with 100 ns rise time. The wire plasma was backlit by the 1.4-1.6 keV continuum radiation produced by a Mo wire X-pinch. The spectrometer employed two spherically bent quartz crystals to record the absorption and backlighter spectra simultaneously. The transition between the dense Al wire core and the coronal plasma is seen as a transition from cold K-edge absorption to Mg-, Na-, and finally Ne-like absorption at the boundary. In the plasma that accumulates between the wires, ionization states up to C-Like Al are observed. The spectrometer geometry and {approx}2{mu}m X-pinch source size provide 0.3 eV spectral resolution and 20 {mu}m spatial resolution enabling us to see 1s{yields} 2p satellite transitions as separate lines as well as O-, F-, and Ne-like 1s{yields} 3p transitions that have not been seen before. A step wedge was used to calibrate the transmission, enabling density to be measured within a factor of two and temperature to be measured within {+-}25%. A genetic algorithm was developed to fit synthetic spectra calculated using the collisional-radiative code SCRAM to the experimental spectra. In order to obtain agreement it was necessary to assume multiple plasma regions with variable thicknesses, thereby allowing the inferred plasma conditions to vary along the absorption path.

  5. Effect of wire shape on wire array discharge

    Energy Technology Data Exchange (ETDEWEB)

    Shimomura, N.; Tanaka, Y.; Yushita, Y.; Nagata, M. [University of Tokushima, Department of Electrical and Electronic Engineering, Tokushima (Japan); Teramoto, Y.; Katsuki, S.; Akiyama, H. [Kumamoto University, Department of Electrical and Computer Engineering, Kumamoto (Japan)

    2001-09-01

    Although considerable investigations have been reported on z-pinches to achieve nuclear fusion, little attention has been given from the point of view of how a wire array consisting of many parallel wires explodes. Instability existing in the wire array discharge has been shown. In this paper, the effect of wire shape in the wire array on unstable behavior of the wire array discharge is represented by numerical analysis. The claws on the wire formed in installation of wire may cause uniform current distribution on wire array. The effect of error of wire diameter in production is computed by Monte Carlo Method. (author)

  6. Integrating electronic information resources for NHS Glasgow staff at the point of need: a model of interlibrary collaboration and resource sharing.

    Science.gov (United States)

    Davies, S; Wales, A

    2001-12-01

    The Glasgow NHS Libraries Consortium has harnessed the political imperative of collaboration and the capability of electronic information resources to address inequalities in access to the knowledge base across NHS Glasgow. They have negotiated consortium arrangements to an extensive range of electronic databases and journals which no single Glasgow NHS library could afford independently. A Project Officer was appointed to undertake the administration, technical work and promotion required to build a Web-based electronic library to deliver resources to all NHS Glasgow staff on an equitable basis. Close partnership with online content providers enabled the Project Officer to find solutions to problems caused by authentication systems and license restrictions. These efforts have culminated in the production of a fully integrated virtual library--the NHS Glasgow e-Library--delivering 11 major electronic databases, 440 full-text electronic journals, 48 electronic textbooks and over 5000 journal contents pages. The NHS Glasgow e-Library is without precedent within the NHS in terms of its wealth of resources, and it provides a model for Scotland-wide access to the knowledge base. The sustainability and transferability of the resource is dependent on a number of key areas-maintenance, user training, evaluation, IT infrastructure and ongoing collaboration and unification. Ongoing research will monitor how far the NHS Glasgow e-Library has strengthened the connection between research evidence and clinical practice.

  7. Comparing Electronic Human Resource Management Systems Efficiency In Production Organization amp Service Organizations

    Directory of Open Access Journals (Sweden)

    Ali Hadian

    2015-08-01

    Full Text Available Today the organizations used information technology in performing human resource department affairs and this is called as electronic human resource management EHRM. In fact as the competitive complexity increases the need for implementing EHRM in production and service businesses increases too. This paper is written in order to specify the importance of implementing EHRM in production and service organizations and also to evaluate efficiency rate and the importance degree in these two ones. In this paper first the topics literature and the most important aspects of implementing these systems will be reviewed and after categorizing these views the hierarchal model will be proposed by applying AHP method. The result of analyzing this model by EXPERT CHOICE software shows that implementing EHRM in both kinds of organizations has the same importance however there is a large difference between them in implementing aspects.

  8. The Synthesis of the Hierarchical Structure of Information Resources for Management of Electronic Commerce Entities

    Directory of Open Access Journals (Sweden)

    Krutova Anzhelika S.

    2017-06-01

    Full Text Available The aim of the article is to develop the theoretical bases for the classification and coding of economic information and the scientific justification of the content of information resources of an electronic commerce enterprise. The essence of information resources for management of electronic business entities is investigated. It is proved that the organization of accounting in e-commerce systems is advisable to be built on the basis of two circuits: accounting for financial flows and accounting associated with transformation of business factors in products and services as a result of production activities. There presented a sequence of accounting organization that allows to combine the both circuits in a single information system, which provides a possibility for the integrated replenishment and distributed simultaneous use of the e-commerce system by all groups of users. It is proved that the guarantee of efficient activity of the information management system of electronic commerce entities is a proper systematization of the aggregate of information resources on economic facts and operations of an enterprise in accordance with the management tasks by building the hierarchy of accounting nomenclatures. It is suggested to understand nomenclature as an objective, primary information aggregate concerning a certain fact of the economic activity of an enterprise, which is characterized by minimum requisites, is entered into the database of the information system and is to be reflected in the accounting system. It is proposed to build a database of e-commerce systems as a part of directories (constants, personnel, goods / products, suppliers, buyers and the hierarchy of accounting nomenclatures. The package of documents regulating the organization of accounting at an enterprise should include: the provision on the accounting services, the order on the accounting policy, the job descriptions, the schedules of information exchange, the report card and

  9. ELECTRONIC EDUCATIONAL RESOURCES FOR ONLINE SUPPORT OF MODERN CHEMISTRY CLASSES IN SPECIALIZED SCHOOL

    Directory of Open Access Journals (Sweden)

    Maria D. Tukalo

    2013-09-01

    Full Text Available This article contains material of some modern electronic educational resources that can be used via the Internet to support the modern chemistry classes in specialized school. It was drawn attention to the educational chemical experiments as means of knowledge; simulated key motivational characteristics to enhance students interest for learning subjects, their cognitive and practical activity in the formation of self-reliance and self-creative; commented forecasts for creating of conditions to enhance the creative potential of students in a modern learning environment.

  10. THE MODEL OF LINGUISTIC TEACHERS’ COMPETENCY DEVELOPMENT ON DESIGNING MULTIMEDIA ELECTRONIC EDUCATIONAL RESOURCES IN THE MOODLE SYSTEM

    Directory of Open Access Journals (Sweden)

    Anton M. Avramchuk

    2017-10-01

    Full Text Available The article is devoted to the problem of developing the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system. The concept of "the competence of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system" is justified and defined. Identified and characterized the components by which the levels of the competency development of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system should be assessed. Developed a model for the development of the competency of teachers of language disciplines on designing multimedia electronic educational resources in the Moodle system, which is based on the main scientific approaches, used in adult education, and consists of five blocks: target, informative, technological, diagnostic and effective.

  11. Open-Source Electronic Health Record Systems for Low-Resource Settings: Systematic Review.

    Science.gov (United States)

    Syzdykova, Assel; Malta, André; Zolfo, Maria; Diro, Ermias; Oliveira, José Luis

    2017-11-13

    Despite the great impact of information and communication technologies on clinical practice and on the quality of health services, this trend has been almost exclusive to developed countries, whereas countries with poor resources suffer from many economic and social issues that have hindered the real benefits of electronic health (eHealth) tools. As a component of eHealth systems, electronic health records (EHRs) play a fundamental role in patient management and effective medical care services. Thus, the adoption of EHRs in regions with a lack of infrastructure, untrained staff, and ill-equipped health care providers is an important task. However, the main barrier to adopting EHR software in low- and middle-income countries is the cost of its purchase and maintenance, which highlights the open-source approach as a good solution for these underserved areas. The aim of this study was to conduct a systematic review of open-source EHR systems based on the requirements and limitations of low-resource settings. First, we reviewed existing literature on the comparison of available open-source solutions. In close collaboration with the University of Gondar Hospital, Ethiopia, we identified common limitations in poor resource environments and also the main requirements that EHRs should support. Then, we extensively evaluated the current open-source EHR solutions, discussing their strengths and weaknesses, and their appropriateness to fulfill a predefined set of features relevant for low-resource settings. The evaluation methodology allowed assessment of several key aspects of available solutions that are as follows: (1) integrated applications, (2) configurable reports, (3) custom reports, (4) custom forms, (5) interoperability, (6) coding systems, (7) authentication methods, (8) patient portal, (9) access control model, (10) cryptographic features, (11) flexible data model, (12) offline support, (13) native client, (14) Web client,(15) other clients, (16) code

  12. In-Situ Wire Damage Detection System

    Science.gov (United States)

    Williams, Martha; Roberson, Luke; Tate, Lanetra; Smith, Trent; Gibson, Tracy; Medelius, Pedro; Jolley, Scott

    2012-01-01

    An In-Situ Wire Damage Detection System (ISWDDS) has been developed that is capable of detecting damage to a wire insulation, or a wire conductor, or to both. The system will allow for realtime, continuous monitoring of wiring health/integrity and reduce the number of false negatives and false positives while being smaller, lighter in weight, and more robust than current systems. The technology allows for improved safety and significant reduction in maintenance hours for aircraft, space vehicles, satellites, and other critical high-performance wiring systems for industries such as energy production and mining. The integrated ISWDDS is comprised of two main components: (1) a wire with an innermost core conductor, an inner insulation film, a conductive layer or inherently conductive polymer (ICP) covering the inner insulation film, an outermost insulation jacket; and (2) smart connectors and electronics capable of producing and detecting electronic signals, and a central processing unit (CPU) for data collection and analysis. The wire is constructed by applying the inner insulation films to the conductor, followed by the outer insulation jacket. The conductive layer or ICP is on the outer surface of the inner insulation film. One or more wires are connected to the CPU using the smart connectors, and up to 64 wires can be monitored in real-time. The ISWDDS uses time domain reflectometry for damage detection. A fast-risetime pulse is injected into either the core conductor or conductive layer and referenced against the other conductor, producing transmission line behavior. If either conductor is damaged, then the signal is reflected. By knowing the speed of propagation of the pulse, and the time it takes to reflect, one can calculate the distance to and location of the damage.

  13. Success criteria for electronic medical record implementations in low-resource settings: a systematic review.

    Science.gov (United States)

    Fritz, Fleur; Tilahun, Binyam; Dugas, Martin

    2015-03-01

    Electronic medical record (EMR) systems have the potential of supporting clinical work by providing the right information at the right time to the right people and thus make efficient use of resources. This is especially important in low-resource settings where reliable data are also needed to support public health and local supporting organizations. In this systematic literature review, our objectives are to identify and collect literature about success criteria of EMR implementations in low-resource settings and to summarize them into recommendations. Our search strategy relied on PubMed queries and manual bibliography reviews. Studies were included if EMR implementations in low-resource settings were described. The extracted success criteria and measurements were summarized into 7 categories: ethical, financial, functionality, organizational, political, technical, and training. We collected 381 success criteria with 229 measurements from 47 articles out of 223 articles. Most papers were evaluations or lessons learned from African countries, published from 1999 to 2013. Almost half of the EMR systems served a specific disease area like human immunodeficiency virus (HIV). The majority of criteria that were reported dealt with the functionality, followed by organizational issues, and technical infrastructures. Sufficient training and skilled personnel were mentioned in roughly 10%. Political, ethical, and financial considerations did not play a predominant role. More evaluations based on reliable frameworks are needed. Highly reliable data handling methods, human resources and effective project management, as well as technical architecture and infrastructure are all key factors for successful EMR implementation. © The Author 2015. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Impact of Knowledge Resources Linked to an Electronic Health Record on Frequency of Unnecessary Tests and Treatments

    Science.gov (United States)

    Goodman, Kenneth; Grad, Roland; Pluye, Pierre; Nowacki, Amy; Hickner, John

    2012-01-01

    Introduction: Electronic knowledge resources have the potential to rapidly provide answers to clinicians' questions. We sought to determine clinicians' reasons for searching these resources, the rate of finding relevant information, and the perceived clinical impact of the information they retrieved. Methods: We asked general internists, family…

  15. Resource conservation approached with an appropriate collection and upgrade-remanufacturing for used electronic products.

    Science.gov (United States)

    Zlamparet, Gabriel I; Tan, Quanyin; Stevels, A B; Li, Jinhui

    2018-03-01

    This comparative research represents an example for a better conservation of resources by reducing the amount of waste (kg) and providing it more value under the umbrella of remanufacturing. The three discussed cases will expose three issues already addressed separately in the literature. The generation of waste electrical and electronic equipment (WEEE) interacts with the environmental depletion. In this article, we gave the examples of addressed issues under the concept of remanufacturing. Online collection opportunity eliminating classical collection, a business to business (B2B) implementation for remanufactured servers and medical devices. The material reuse (recycling), component sustainability, reuse (part harvesting), product reuse (after repair/remanufacturing) indicates the recovery potential using remanufacturing tool for a better conservation of resources adding more value to the products. Our findings can provide an overview of new system organization for the general collection, market potential and the technological advantages using remanufacturing instead of recycling of WEEE or used electrical and electronic equipment. Copyright © 2017. Published by Elsevier Ltd.

  16. Hierarchical structures in cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2013-01-01

    , and high-angle boundaries form in the A_BC structure parallel to the cementite lamellae. The structural and crystallographic analyses suggest that boundary strengthening and dislocation strengthening are important mechanisms in the cold-drawn wire. However, differences in structural parameters between......The microstructure and crystallography of drawn pearlitic steel wires have been quantified by a number of electron microscopy techniques including scanning electron microscopy, transmission electron microscopy, electron backscatter diffraction and nanobeam diffraction, with focus on the change...

  17. Reducing clinical trial monitoring resource allocation and costs through remote access to electronic medical records.

    Science.gov (United States)

    Uren, Shannon C; Kirkman, Mitchell B; Dalton, Brad S; Zalcberg, John R

    2013-01-01

    With electronic medical records (eMRs), the option now exists for clinical trial monitors to perform source data verification (SDV) remotely. We report on a feasibility study of remote access to eMRs for SDV and the potential advantages of such a process in terms of resource allocation and cost. The Clinical Trials Unit at the Peter MacCallum Cancer Centre, in collaboration with Novartis Pharmaceuticals Australia, conducted a 6-month feasibility study of remote SDV. A Novartis monitor was granted dedicated software and restricted remote access to the eMR portal of the cancer center, thereby providing an avenue through which perform SDV. Six monitoring visits were conducted during the study period, four of which were performed remotely. The ability to conduct two thirds of the monitoring visits remotely in this complex phase III study resulted in an overall cost saving to Novartis. Similarly, remote monitoring eased the strain on internal resources, particularly monitoring space and hospital computer terminal access, at the cancer center. Remote access to patient eMRs for SDV is feasible and is potentially an avenue through which resources can be more efficiently used. Although this feasibility study involved limited numbers, there is no limit to scaling these processes to any number of patients enrolled onto large clinical trials.

  18. Electronic theses and dissertations: a review of this valuable resource for nurse scholars worldwide.

    Science.gov (United States)

    Goodfellow, L M

    2009-06-01

    A worldwide repository of electronic theses and dissertations (ETDs) could provide worldwide access to the most up-to-date research generated by masters and doctoral students. Until that international repository is established, it is possible to access some of these valuable knowledge resources. ETDs provide a technologically advanced medium with endless multimedia capabilities that far exceed the print and bound copies of theses and dissertations housed traditionally in individual university libraries. CURRENT USE: A growing trend exists for universities worldwide to require graduate students to submit theses or dissertations as electronic documents. However, nurse scholars underutilize ETDs, as evidenced by perusing bibliographic citation lists in many of the research journals. ETDs can be searched for and retrieved through several digital resources such as the Networked Digital Library of Theses and Dissertations (http://www.ndltd.org), ProQuest Dissertations and Theses (http://www.umi.com), the Australasian Digital Theses Program (http://adt.caul.edu.au/) and through individual university web sites and online catalogues. An international repository of ETDs benefits the community of nurse scholars in many ways. The ability to access recent graduate students' research electronically from anywhere in the world is advantageous. For scholars residing in developing countries, access to these ETDs may prove to be even more valuable. In some cases, ETDs are not available for worldwide access and can only be accessed through the university library from which the student graduated. Public access to university library ETD collections is not always permitted. Nurse scholars from both developing and developed countries could benefit from ETDs.

  19. Wire + Arc Additive Manufacturing

    OpenAIRE

    Williams, Stewart W.; Martina, Filomeno; Addison, Adrian C.; Ding, Jialuo; Pardal, Goncalo; Colegrove, Paul A.

    2016-01-01

    Depositing large components (>10 kg) in titanium, aluminium, steel and other metals is possible using Wire + Arc Additive Manufacturing. This technology adopts arc welding tools and wire as feedstock for additive manufacturing purposes. High deposition rates, low material and equipment costs, and good structural integrity make Wire+Arc Additive Manufacturing a suitable candidate for replacing the current method of manufacturing from solid billets or large forgings, especially with regards to ...

  20. Photovoltaic Wire Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  1. 1998 wire development workshop proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development.

  2. From Millennium ERM to Proquest 360 Resource Manager: Implementing a new Electronic Resources Management System ERMS in an International Graduate Research University in Saudi Arabia

    KAUST Repository

    Ramli, Rindra M.

    2017-05-17

    An overview of the Recommendation Study and the subsequent Implementation of a new Electronic Resources Management system ERMS in an international graduate research university in the Kingdom of Saudi Arabia. It covers the timeline, deliverables and challenges as well as lessons learnt by the Project Team.

  3. Tungsten quasispherical wire loads with a profiled mass

    Energy Technology Data Exchange (ETDEWEB)

    Grabovskii, E. V.; Dzhangobegov, V. V., E-mail: jvv88@triniti.ru; Oleinik, G. M.; Rodionov, R. N. [State Research Center of the Russian Federation Troitsk Institute for Innovation and Fusion Research (TRINITI) (Russian Federation)

    2015-12-15

    Wire arrays made from micrometer tungsten wires with linear mass profiled along their height are developed for experiments on the generation of X-ray radiation upon pinch compression with a current of ∼3 MA at a pulse duration of ∼100 ns. Wires are imaged with a scanning electron microscope, and their diameter is determined. It is shown that the arrays have such a profile of height distribution of linear mass that allows for compact spherical compression upon current implosion.

  4. DEVELOPMENT AND USAGE OF THE ELECTRONIC VIDEO RESOURCES FOR EDUCATIONAL PURPOSES

    Directory of Open Access Journals (Sweden)

    Yaroslav M. Hlynsky

    2017-04-01

    Full Text Available This article discusses the theoretical foundation, the creation and implementation of the electronic educational video resources (EEVR in the example of the development and the usage of the collection of video tutorials in event-driven programming theme, which is studied in the framework of the subject "Informatics" by students of many specialties. It offers some development of the existing conceptual and categorical apparatus concerning EEVR development. It is alleged that the video tutorials allow you to automate the process of learning, redistribute instructional time for the benefit of students' independent work, to provide classroom release time for the teaching of the theoretical issues of the course that is aimed at improving the fundamental nature of training. Practical recommendations for the development of the effective EEVR, which may be useful for the authors of e-learning courses for students of different forms of training are proposed.

  5. [HYGIENIC REGULATION OF THE USE OF ELECTRONIC EDUCATIONAL RESOURCES IN THE MODERN SCHOOL].

    Science.gov (United States)

    Stepanova, M I; Aleksandrova, I E; Sazanyuk, Z I; Voronova, B Z; Lashneva, L P; Shumkova, T V; Berezina, N O

    2015-01-01

    We studied the effect of academic studies with the use a notebook computer and interactive whiteboard on the functional state of an organism of schoolchildren. Using a complex of hygienic and physiological methods of the study we established that regulation of the computer activity of students must take into account not only duration but its intensity either. Design features of a notebook computer were shown both to impede keeping the optimal working posture in primary school children and increase the risk offormation of disorders of vision and musculoskeletal system. There were established the activating influence of the interactive whiteboard on performance activities and favorable dynamics of indices of the functional state of the organism of students under keeping optimal density of the academic study and the duration of its use. There are determined safety regulations of the work of schoolchildren with electronic resources in the educational process.

  6. Transport in quantum wires

    Indian Academy of Sciences (India)

    This motivated us to study the LL model of a quantum wire, with Fermi liquid leads and the unusual feature of ... of quantized conductance even in clean quantum wires and a novel odd–even effect in the presence of a .... But in one dimension, it is well-known that the FL theory breaks down, and the ground state is a ...

  7. Commercial and Industrial Wiring.

    Science.gov (United States)

    Kaltwasser, Stan; Flowers, Gary

    This module is the third in a series of three wiring publications, includes additional technical knowledge and applications required for job entry in the commercial and industrial wiring trade. The module contains 15 instructional units that cover the following topics: blueprint reading and load calculations; tools and equipment; service;…

  8. Availability, Use and Constraints to Use of Electronic Information Resources by Postgraduates Students at the University of Ibadan

    Directory of Open Access Journals (Sweden)

    Dare Samuel Adeleke

    2017-12-01

    Full Text Available Availability, awareness and use of electronic resources provide access to authoritative, reliable, accurate and timely access to information. The use of electronic information resources (EIRs can enable innovation in teaching and increase timeliness in research of postgraduate students which will eventual result into encouragement of the expected research-led enquiry in this digital age. The study adopted a descriptive survey design. Samples of 300 of postgraduate students within seven out 13 Faculties were randomly selected. Data were collected using questionnaire designed to elicit response from respondents and data were analyzed using descriptive statistics methods percentages, mean, and standard deviation. Results indicated that internet was ranked most available and used in the university. Low level of usage of electronic resources, in particular, full texts data bases is linked to a number of constraints: Interrupted power supply was ranked highest among other factors as speed and capacity of computers, retrieval of records with high recall and low precision, retrieving records relevant to information need, lack of knowledge of search techniques to retrieve information effectively, non possession of requisite IT skills and problems accessing the internet. The study recommended that usage of electronic resources be made compulsory, intensifying awareness campaigns concerning the availability, training on use of electronic resources and the problem of power outage be addressed.

  9. 30 CFR 75.516 - Power wires; support.

    Science.gov (United States)

    2010-07-01

    .... All power wires (except trailing cables on mobile equipment, specially designed cables conducting high-voltage power to underground rectifying equipment or transformers, or bare or insulated ground and return... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Power wires; support. 75.516 Section 75.516...

  10. Study of structural and electronic environments of hydrogenated amorphous silicon carbonitride (a-SiCN:H) films deposited by hot wire chemical vapor deposition

    Science.gov (United States)

    Swain, Bibhu P.; Hwang, Nong M.

    2008-06-01

    Hydrogenated amorphous silicon carbon nitride (a-SiCN:H) thin films were deposited by hot wire chemical vapor deposition (HWCVD) using SiH 4, CH 4, NH 3 and H 2 as precursors. The effects of the H 2 dilution on structural and chemical bonding of a-SiCN:H has been investigated by Raman and X-ray photoelectron spectroscopy (XPS). Increasing the H 2 flow rate in the precursor gas more carbon is introduced into the a-SiCN:H network resulting in decrease of silicon content in the film from 41 at.% to 28.8 at.% and sp 2 carbon cluster increases when H 2 flow rate is increased from 0 to 20 sccm.

  11. Study of structural and electronic environments of hydrogenated amorphous silicon carbonitride (a-SiCN:H) films deposited by hot wire chemical vapor deposition

    Energy Technology Data Exchange (ETDEWEB)

    Swain, Bibhu P. [National Research Laboratory of Charged Nanoparticles, School of Materials Science and Engineering, Seoul National University, Seoul (Korea, Republic of)], E-mail: swain@snu.ac.kr; Hwang, Nong M. [National Research Laboratory of Charged Nanoparticles, School of Materials Science and Engineering, Seoul National University, Seoul (Korea, Republic of)

    2008-06-30

    Hydrogenated amorphous silicon carbon nitride (a-SiCN:H) thin films were deposited by hot wire chemical vapor deposition (HWCVD) using SiH{sub 4}, CH{sub 4}, NH{sub 3} and H{sub 2} as precursors. The effects of the H{sub 2} dilution on structural and chemical bonding of a-SiCN:H has been investigated by Raman and X-ray photoelectron spectroscopy (XPS). Increasing the H{sub 2} flow rate in the precursor gas more carbon is introduced into the a-SiCN:H network resulting in decrease of silicon content in the film from 41 at.% to 28.8 at.% and sp{sup 2} carbon cluster increases when H{sub 2} flow rate is increased from 0 to 20 sccm.

  12. Factors Influencing Students' Use of Electronic Resources and their Opinions About this Use: The Case of Students at An-Najah National University

    Directory of Open Access Journals (Sweden)

    Wajeeh M. Daher

    2010-12-01

    Full Text Available Electronic resources are becoming an integral part of the modern life and of the educational scene, especially the high education scene. In this research we wanted to verify what influences first degree university students' use of electronic resources and their opinions regarding this use. Collecting data from 202 students and analyzing it using SPSS, we found that more than one half of the participants had high level of electronic media use and more than one third had moderate level of electronic media use. These levels of use indicate the students' awareness of the role and benefits of electronic media use. Regarding the factors that influence the students' se of electronic resources we found that the student's use of electronic resources had significant strong positive relationships with the provision of electronic resources by the academic institution. It had significant moderate positive relationships with the resources characteristics and the course requirement, and had significant weak relationships with the instructor's support and the student's characteristics. We explained these relationships as resulting from the influence of the surrounding community. Regarding the students' opinions about the use of electronic resources, we found that the student's opinion of electronic resources has significant strong positive relationships with student's use of electronic resources, level of this use, the academic institution available facilities, student's characteristics and resources characteristics. It does not have significant relationships with the instructor's support or the course requirement. We explained these relationships depending on activity theory and its integration with ecological psychology.

  13. SAGES: a suite of freely-available software tools for electronic disease surveillance in resource-limited settings.

    Directory of Open Access Journals (Sweden)

    Sheri L Lewis

    Full Text Available Public health surveillance is undergoing a revolution driven by advances in the field of information technology. Many countries have experienced vast improvements in the collection, ingestion, analysis, visualization, and dissemination of public health data. Resource-limited countries have lagged behind due to challenges in information technology infrastructure, public health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES is a collection of modular, flexible, freely-available software tools for electronic disease surveillance in resource-limited settings. One or more SAGES tools may be used in concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility allows for the development of an inexpensive, customized, and sustainable disease surveillance system. The ability to rapidly assess anomalous disease activity may lead to more efficient use of limited resources and better compliance with World Health Organization International Health Regulations.

  14. SAGES: A Suite of Freely-Available Software Tools for Electronic Disease Surveillance in Resource-Limited Settings

    Science.gov (United States)

    Lewis, Sheri L.; Feighner, Brian H.; Loschen, Wayne A.; Wojcik, Richard A.; Skora, Joseph F.; Coberly, Jacqueline S.; Blazes, David L.

    2011-01-01

    Public health surveillance is undergoing a revolution driven by advances in the field of information technology. Many countries have experienced vast improvements in the collection, ingestion, analysis, visualization, and dissemination of public health data. Resource-limited countries have lagged behind due to challenges in information technology infrastructure, public health resources, and the costs of proprietary software. The Suite for Automated Global Electronic bioSurveillance (SAGES) is a collection of modular, flexible, freely-available software tools for electronic disease surveillance in resource-limited settings. One or more SAGES tools may be used in concert with existing surveillance applications or the SAGES tools may be used en masse for an end-to-end biosurveillance capability. This flexibility allows for the development of an inexpensive, customized, and sustainable disease surveillance system. The ability to rapidly assess anomalous disease activity may lead to more efficient use of limited resources and better compliance with World Health Organization International Health Regulations. PMID:21572957

  15. Wire chambers revisited.

    Science.gov (United States)

    Ott, R J

    1993-04-01

    Detectors used for radioisotope imaging have, historically, been based on scintillating crystal/photomultiplier combinations in various forms. From the rectilinear scanner through to modern gamma cameras and positron cameras, the basic technology has remained much the same. Efforts to overcome the limitations of this form of technology have foundered on the inability to reproduce the required sensitivity, spatial resolution and sensitive area at acceptable cost. Multiwire proportional chambers (MWPCs) have long been used as position-sensitive charged particle detectors in nuclear and high-energy physics. MWPCs are large-area gas-filled ionisation chambers in which large arrays of fine wires are used to measure the position of ionisation produced in the gas by the passage of charged particles. The important properties of MWPCs are high-spatial-resolution, large-area, high-count-rate performance at low cost. For research applications, detectors several metres square have been built and small-area detectors have a charged particle resolution of 0.4 mm at a count rate of several million per second. Modification is required to MWPCs for nuclear medicine imaging. As gamma rays or X-rays cannot be detected directly, they must be converted into photo- or Compton scatter electrons. Photon-electron conversion requires the use of high atomic number materials in the body of the chamber. Pressurised xenon is the most useful form of "gas only" photon-electron convertor and has been used successfully in a gamma camera for the detection of gamma rays at energies below 100 keV. This camera has been developed specifically for high-count-rate first-pass cardiac imaging. This high-pressure xenon gas MWPC is the key to a highly competitive system which can outperform scintillator-based systems. The count rate performance is close to a million counts per second and the intrinsic spatial resolution is better than the best scintillator-based camera. The MWPC camera produces quantitative

  16. Elastic anisotropy in multifilament Nb$_3$Sn superconducting wires

    CERN Document Server

    Scheuerlein, C; Alknes, P; Arnau, G; Bjoerstad, R; Bordini, B

    2015-01-01

    The elastic anisotropy caused by the texture in the Nb3Sn filaments of PIT and RRP wires has been calculated by averaging the estimates of Voigt and Reuss, using published Nb3Sn single crystal elastic constants and the Nb3Sn grain orientation distribution determined in both wire types by Electron Backscatter Diffraction. At ambient temperature the calculated Nb3Sn E-moduli in axial direction in the PIT and the RRP wire are 130 GPa and 140 GPa, respectively. The calculated E-moduli are compared with tensile test results obtained for the corresponding wires and extracted filament bundles.

  17. Theoretical Aspects of the Use of Electronic Educational Resources in Professional Activity of Future Teachers of Technology

    OpenAIRE

    Iryna Smyrnova

    2017-01-01

    In this paper, we tried to determine the requirements for ESM, to study theoretical aspects of electronic educational resources in the professional activity of future teachers. The results created by the introduction of our course “Methodology development and use of electronic educational resources” for future teachers of technology ITOS in the process of professional specialty “Technology” in the educational process of higher educational institutions of Ukraine. The article states the rapid ...

  18. 30 CFR 75.521 - Lightning arresters; ungrounded and exposed power conductors and telephone wires.

    Science.gov (United States)

    2010-07-01

    ... Electrical Equipment-General § 75.521 Lightning arresters; ungrounded and exposed power conductors and telephone wires. Each ungrounded, exposed power conductor and each ungrounded, exposed telephone wire that... power conductors and telephone wires. 75.521 Section 75.521 Mineral Resources MINE SAFETY AND HEALTH...

  19. Dynamics of Anderson localization in disordered wires

    Science.gov (United States)

    Khalaf, E.; Ostrovsky, P. M.

    2017-11-01

    We consider the dynamics of an electron in an infinite disordered metallic wire. We derive exact expressions for the probability of diffusive return to the starting point in a given time. The result is valid for wires with or without time-reversal symmetry and allows for the possibility of topologically protected conducting channels. In the absence of protected channels, Anderson localization leads to a nonzero limiting value of the return probability at long times, which is approached as a negative power of time with an exponent depending on the symmetry class. When topologically protected channels are present (in a wire of either unitary or symplectic symmetry), the probability of return decays to zero at long time as a power law whose exponent depends on the number of protected channels. Technically, we describe the electron dynamics by the one-dimensional supersymmetric nonlinear sigma model. We derive an exact identity that relates any local dynamical correlation function in a disordered wire of unitary, orthogonal, or symplectic symmetry to a certain expectation value in the random matrix ensemble of class AIII, CI, or DIII, respectively. The established exact mapping from a one- to a zero-dimensional sigma model is very general and can be used to compute any local observable in a disordered wire.

  20. Resources.

    Science.gov (United States)

    Stewart, John; MacDonald, Ian

    1980-01-01

    Presents a guide to resources on television drama available to teachers for classroom use in television curriculum. Lists American and British television drama videorecordings of both series and individual presentations and offers a bibliography of "one-off" single fiction plays produced for British television. (JMF)

  1. Ultrathin Nanocrystalline Magnetic Wires

    Directory of Open Access Journals (Sweden)

    Horia Chiriac

    2017-02-01

    Full Text Available The magnetic characteristics of FINEMET type glass-coated nanowires and submicron wires are investigated by taking into account the structural evolution induced by specific annealing all the way from a fully amorphous state to a nanocrystalline structure. The differences between the magnetic properties of these ultrathin wires and those of the thicker glass-coated microwires and “conventional” wires with similar structures have been emphasized and explained phenomenologically. The domain wall propagation in these novel nanowires and submicron wires, featuring a combination between an amorphous and a crystalline structure, has also been studied, given the recent interest in the preparation and investigation of new materials suitable for the development of domain wall logic applications.

  2. Dual wire weld feed proportioner

    Science.gov (United States)

    Nugent, R. E.

    1968-01-01

    Dual feed mechanism enables proportioning of two different weld feed wires during automated TIG welding to produce a weld alloy deposit of the desired composition. The wires are fed into the weld simultaneously. The relative feed rates of the wires and the wire diameters determine the weld deposit composition.

  3. Impact of Electronic Resources and Usage in Academic Libraries in Ghana: Evidence from Koforidua Polytechnic & All Nations University College, Ghana

    Science.gov (United States)

    Akussah, Maxwell; Asante, Edward; Adu-Sarkodee, Rosemary

    2015-01-01

    The study investigates the relationship between impact of electronic resources and its usage in academic libraries in Ghana: evidence from Koforidua Polytechnic & All Nations University College, Ghana. The study was a quantitative approach using questionnaire to gather data and information. A valid response rate of 58.5% was assumed. SPSS…

  4. Utilization of Electronic Information Resources by Undergraduate Students of University of Ibadan: A Case Study of Social Sciences and Education

    Science.gov (United States)

    Owolabi, Sola; Idowu, Oluwafemi A.; Okocha, Foluke; Ogundare, Atinuke Omotayo

    2016-01-01

    The study evaluated utilization of electronic information resources by undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan. The study adopted a descriptive survey design with a study population of 1872 undergraduates in the Faculties of Education and the Social Sciences in University of Ibadan, from which a…

  5. True Serials: A True Solution for Electronic Resource Management Needs in a Medium-Size Academic Library

    Science.gov (United States)

    Milczarski, Vivian; Garofalo, Denise A.

    2011-01-01

    A desire for more functionality seemed to clash with the fiscal reality of limited funds, but after investigating alternatives, Mount Saint Mary College was able to provide its faculty and students with a more useful and function-rich electronic resource management through a move to a hosted open source service. (Contains 8 figures.)

  6. Single Wire Detector Performance Over One Year of Operation

    CERN Document Server

    Hervas Aguilar, David Alberto

    2014-01-01

    Abstract When ionizing radiation passes through gas chambers in single wire detectors gas molecules separate into ions and electrons. By applying a strong localized electric field near the single wire an avalanche of electrons is created and it can be collected. The current produced in the wire is then proportional to the energy of the particle detected. Nevertheless, many factors can contribute to detector aging effects which are visible in a loss of gain caused by deposition of contaminants on the collecting wire. This study consists on novel data analysis techniques used to process large amounts of data produced by two simultaneously running single wire detectors. Aging effects are analyzed while environmental fluctuations are corrected for. A series of scripts carry out data filtering, data matching, corrections, and finally trend plotting by using ROOT’s extensive libraries developed at CERN.

  7. Quantum conductance in silicon quantum wires

    CERN Document Server

    Bagraev, N T; Klyachkin, L E; Malyarenko, A M; Gehlhoff, W; Ivanov, V K; Shelykh, I A

    2002-01-01

    The results of investigations of electron and hole quantum conductance staircase in silicon quantum wires are presented. The characteristics of self-ordering quantum wells of n- and p-types, which from on the silicon (100) surface in the nonequilibrium boron diffusion process, are analyzed. The results of investigations of the quantum conductance as the function of temperature, carrier concentration and modulation degree of silicon quantum wires are given. It is found out, that the quantum conductance of the one-dimensional channels is observed, for the first time, at an elevated temperature (T >= 77 K)

  8. Magnetoresistance peculiarities of bismuth wires in high magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Condrea, E., E-mail: condrea@nano.asm.md [Institute of Electronic Engineering and Nanotechnologies, Academy of Science of Moldova, 2028 Chisinau, Republic of Moldova (Moldova, Republic of); International Laboratory of High Magnetic Fields and Low Temperatures, Gajowicka 95, 51-421 Wroclaw (Poland); Gilewski, A. [International Laboratory of High Magnetic Fields and Low Temperatures, Gajowicka 95, 51-421 Wroclaw (Poland); MagNet, 50-421 Wroclaw (Poland); Nicorici, A. [Institute of Electronic Engineering and Nanotechnologies, Academy of Science of Moldova, 2028 Chisinau, Republic of Moldova (Moldova, Republic of)

    2016-03-11

    Magnetoresistance measurements of Bi wires performed in the magnetic field oriented along the bisector axis revealed unexpected anomalous peaks in a high magnetic field far above the quantum limit of the electrons. By combining a magnetic field and an uniaxial strain, we obtained a modification of the electronic structure; as a result, the quantum limit for light and heavy electrons is changed in a different way. For the case where heavy electrons are in the quantum limit, a correlation between the exit of the lowest Landau level of light electrons and the Lifshitz transition was found. - Highlights: • Glass-coated single-crystalline Bi wires attain high limit of elastic strain of up to 3.0%. • Selective modification of the electronic structure of Bi wires is obtained by combining a high magnetic field and uniaxial strain. • The correlation between the exit of the lowest Landau level of electrons and Lifshitz transition was found.

  9. The Use of Electronic Resources by Academic Staff at the University of Ilorin, Nigeria

    Science.gov (United States)

    Tella, Adeyinka; Orim, Faith; Ibrahim, Dauda Morenikeji; Memudu, Suleiman Ajala

    2018-01-01

    The use of e-resources is now commonplace among academics in tertiary educational institutions the world over. Many academics including those in the universities are exploring the opportunities of e-resources to facilitate teaching and research. As the use of e-resources is increasing particularly among academics at the University of Ilorin,…

  10. Novel open-source electronic medical records system for palliative care in low-resource settings.

    Science.gov (United States)

    Shah, Kamal G; Slough, Tara Lyn; Yeh, Ping Teresa; Gombwa, Suave; Kiromera, Athanase; Oden, Z Maria; Richards-Kortum, Rebecca R

    2013-08-14

    The need for palliative care in sub-Saharan Africa is staggering: this region shoulders over 67% of the global burden of HIV/AIDS and cancer. However, provisions for these essential services remain limited and poorly integrated with national health systems in most nations. Moreover, the evidence base for palliative care in the region remains scarce. This study chronicles the development and evaluation of DataPall, an open-source electronic medical records system that can be used to track patients, manage data, and generate reports for palliative care providers in these settings.DataPall was developed using design criteria encompassing both functional and technical objectives articulated by hospital leaders and palliative care staff at a leading palliative care center in Malawi. The database can be used with computers that run Windows XP SP 2 or newer, and does not require an internet connection for use. Subsequent to its development and implementation in two hospitals, DataPall was tested among both trained and untrained hospital staff populations on the basis of its usability with comparison to existing paper records systems as well as on the speed at which users could perform basic database functions. Additionally, all participants evaluated this program on a standard system usability scale. In a study of health professionals in a Malawian hospital, DataPall enabled palliative care providers to find patients' appointments, on average, in less than half the time required to locate the same record in current paper records. Moreover, participants generated customizable reports documenting patient records and comprehensive reports on providers' activities with little training necessary. Participants affirmed this ease of use on the system usability scale. DataPall is a simple, effective electronic medical records system that can assist in developing an evidence base of clinical data for palliative care in low resource settings. The system is available at no cost, is

  11. A new route to process diamond wires

    Directory of Open Access Journals (Sweden)

    Marcello Filgueira

    2003-06-01

    Full Text Available We propose an original route to process diamond wires, denominated In Situ Technology, whose fabrication involves mechanical conformation processes, such as rotary forging, copper tubes restacking, and thermal treatments, such as sintering and recrystallisation of a bronze 4 wt.% diamond composite. Tensile tests were performed, reaching an ultimate tensile strength (UTS of 230 MPa for the diameter of Æ = 1.84 mm. Scanning electron microscopy showed the diamond crystals distribution along the composite rope during its manufacture, as well as the diamond adhesion to the bronze matrix. Cutting tests were carried out with the processed wire, showing a probable performance 4 times higher than the diamond sawing discs, however its probable performance was about 5 to 8 times less than the conventional diamond wires (pearl system due to the low abrasion resistance of the bronze matrix, and low adhesion between the pair bronze-diamond due to the use of not metallised diamond single crystals.

  12. Human resource requirements for quality-assured electronic data capture of the tuberculosis case register

    Directory of Open Access Journals (Sweden)

    Hoa Nguyen B

    2012-01-01

    Full Text Available Abstract Background The tuberculosis case register is the data source for the reports submitted by basic management units to the national tuberculosis program. Our objective was to measure the data entry time required to complete and double-enter one record, and to estimate the time for the correction of errors in the captured information from tuberculosis case registers in Cambodia and Viet Nam. This should assist in quantifying the additional requirements in human resources for national programs moving towards electronic recording and reporting. Methods Data from a representative sample of tuberculosis case registers from Cambodia and Viet Nam were double-entered and discordances resolved by rechecking the original case register. Computer-generated data entry time recorded the time elapsed between opening of a new record and saving it to disk. Results The dataset comprised 22,732 double-entered records of 11,366 patients (37.1% from Cambodia and 62.9% from Viet Nam. The mean data entry times per record were 97.5 (95% CI: 96.2-98.8 and 66.2 (95% CI: 59.5-73.0 seconds with medians of 90 and 31 s respectively in Cambodia and in Viet Nam. The percentage of records with an error was 6.0% and 39.0% respectively in Cambodia and Viet Nam. Data entry time was inversely associated with error frequency. We estimate that approximately 118-person-hours were required to produce 1,000 validated records. Conclusions This study quantifies differences between two countries for data entry time for the tuberculosis case register and frequencies of data entry errors and suggests that higher data entry speed is partially offset by requiring revisiting more records for corrections.

  13. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  14. Wire scanner software and firmware issues

    Energy Technology Data Exchange (ETDEWEB)

    Gilpatrick, John Doug [Los Alamos National Laboratory

    2008-01-01

    The Los Alamos Neutron Science Center facility presently has 110 slow wire scanning profile measurement instruments located along its various beam lines. These wire scanners were developed and have been operating for at least 30 years. While the wire scanners solved many problems to operate and have served the facility well they have increasingly suffered from several problems or limitations, such as maintenance and reliability problems, antiquated components, slow data acquisition, and etc. In order to refurbish these devices, these wire scanners will be replaced with newer versions. The replacement will consist of a completely new beam line actuator, new cables, new electronics and brand new software and firmware. This note describes the functions and modes of operation that LabVIEW VI software on the real time controller and FPGA LabVIEW firmware will be required. It will be especially interesting to understand the overall architecture of these LabVIEW VIs. While this note will endeavor to describe all of the requirements and issues for the wire scanners, undoubtedly, there will be missing details that will be added as time progresses.

  15. The PS Booster Fast Wire Scanner

    CERN Document Server

    Burger, S; Priestnall, K; Raich, U

    2003-01-01

    The very tight emittance budget for LHC type beams makes precise emittance measurements in the injector complex a necessity. The PS machine uses 2 fast wire scanners per transverse plane for emittance measurement of the circulating beams. In order to ease comparison the same type of wire scanners have been newly installed in the upstream machine, the PS Booster, where each of the 4 rings is equipped with 2 wire scanners measuring the horizontal and vertical profiles. Those wire scanners use new and more modern control and readout electronics featuring dedicated intelligent motor movement controllers, which relieves the very stringent real time constraints due to the very high speed of 20m/s. In order to be able to measure primary beams at the very low injection energy of the Booster (50MeV) secondary emission currents from the wire can be measured as well as secondary particle flows at higher primary particle energies during and after acceleration. The solution adopted for the control of the devices is descri...

  16. Use and Cost of Electronic Resources in Central Library of Ferdowsi University Based on E-metrics

    Directory of Open Access Journals (Sweden)

    Mohammad Reza Davarpanah

    2012-07-01

    Full Text Available The purpose of this study was to investigate the usage of electronic journals in Ferdowsi University, Iran based on e-metrics. The paper also aimed to emphasize the analysis of cost-benefit and the correlation between the journal impact factors and the usage data. In this study experiences of Ferdowsi University library on licensing and usage of electronic resources was evaluated by providing a cost-benefit analysis based on the cost and usage statistics of electronic resources. Vendor-provided data were also compared with local usage data. The usage data were collected by tracking web-based access locally, and by collecting vender-provided usage data. The data sources were one-year of vendor-supplied e-resource usage data such as Ebsco, Elsevier, Proquest, Emerald, Oxford and Springer and local usage data collected from the Ferdowsi university web server. The study found that actual usage values differ for vendor-provided data and local usage data. Elsevier has got the highest usage degree in searches, sessions and downloads. Statistics also showed that a small number of journals satisfy significant amount of use while the majority of journals were used less frequent and some were never used at all. The users preferred the PDF rather than HTML format. The data in subject profile suggested that the provided e-resources were best suited to certain subjects. There was no correlation between IF and electronic journal use. Monitoring the usage of e-resources gained increasing importance for acquisition policy and budget decisions. The article provided information about local metrics for the six surveyed vendors/publishers, e.g. usage trends, requests per package, cost per use as related to the scientific specialty of the university.

  17. Wire core reactor for NTP

    Science.gov (United States)

    Harty, R. B.

    1991-01-01

    The development of the wire core system for Nuclear Thermal Propulsion (NTP) that took place from 1963 to 1965 is discussed. A wire core consists of a fuel wire with spacer wires. It's an annular flow core having a central control rod. There are actually four of these, with beryllium solid reflectors on both ends and all the way around. Much of the information on the concept is given in viewgraph form. Viewgraphs are presented on design details of the wire core, the engine design, engine weight vs. thrust, a technique used to fabricate the wire fuel element, and axial temperature distribution.

  18. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  19. Wiring and lighting

    CERN Document Server

    Kitcher, Chris

    2013-01-01

    Wiring and Lighting provides a comprehensive guide to DIY wiring around the home. It sets out the regulations and legal requirements surrounding electrical installation work, giving clear guidelines that will enable the reader to understand what electrical work they are able to carry out, and what the testing and certification requirements are once the work is completed. Topics covered include: Different types of circuits; Types of cables and cable installation under floors and through joists; Isolating, earthing and bonding; Accessory boxes and fixings; Voltage bands; Detailed advice on safe

  20. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  1. Effective Knowledge Development in Secondary Schools Educational Level in Contemporary Information Age: Assessment of Availability of Electronic Information Resources in Nigerian School Libraries

    Science.gov (United States)

    Bello, Stephen Adeyemi; Ojo, Funmilayo Roseline; Ocheje, Charles Bala

    2015-01-01

    Relevant electronic information resources in contemporary information age are necessity to buttress teaching and learning for effective knowledge development in educational institutions. The purpose of the study is to know the state of availability of electronic information resources in government owned secondary school libraries in Ijumu Local…

  2. Magnetic domain propagation in Pt/Co/Pt micro wires with engineered coercivity gradients along and across the wire

    Energy Technology Data Exchange (ETDEWEB)

    Jarosz, A., E-mail: arctgh@ifmpan.poznan.pl [Institute of Molecular Physics, Polish Academy of Sciences, ul. M. Smoluchowskiego 17, 60-179 Poznań (Poland); Gaul, A. [Department of Physics and Center for Interdisciplinary Nanostructure Science and Technology (CINSaT), University of Kassel, Heinrich-Plett-Str. 40, D-34132 Kassel (Germany); Urbaniak, M. [Institute of Molecular Physics, Polish Academy of Sciences, ul. M. Smoluchowskiego 17, 60-179 Poznań (Poland); Ehresmann, A. [Department of Physics and Center for Interdisciplinary Nanostructure Science and Technology (CINSaT), University of Kassel, Heinrich-Plett-Str. 40, D-34132 Kassel (Germany); Stobiecki, F. [Institute of Molecular Physics, Polish Academy of Sciences, ul. M. Smoluchowskiego 17, 60-179 Poznań (Poland)

    2017-08-01

    Highlights: • Electron lithography and ion bombardment were used to modify the Co/Pt micro-wires. • Two-dimensional perpendicular magnetic anisotropy gradient was engineered. • Engineered anisotropy gradient allowed to control domain wall positions in the wires. • Simulations confirm the influence of defects on a remanent state of the wires. - Abstract: Pt(15 nm)/[Co(0.6 nm)/Pt(1.5 nm)]{sub 4} multilayers with perpendicular magnetic anisotropy were patterned into several-micrometer wide wires by electron-beam lithography. Bombarding the wires with He{sup +} ions with a fluence gradient along the wire results in a spatial gradient of switching fields that allows a controllable positioning of domain walls. The influence of the reduced anisotropy near the wire edges causes a remanent state in which the reversal close to the long edges precedes that in the middle of the wires. Experiments using Kerr microscopy prove this effect and micromagnetic simulations corroborate that a decrease of the anisotropy at the edges is responsible for the effect.

  3. Research regarding wires elastic deformations influence on joints positioning of a wire-driven robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-08-01

    In this paper, we present the influence of driving wires deformation on positioning precision of joints from an elephant's trunk robotic arm. Robotic arms driven by wires have the joint accuracy largely depending on wires rigidity. The joint moment of resistance causes elastic deformation of wires and it is determined by: manipulated object load, weight loads previous to the analyzed joint and inherent resistance moment of joint. Static load analysis emphasizes the particular wires elastic deformation of each driven joint from an elephant's trunk robotic arm with five degrees of freedom. We consider the case of a constant manipulated load. Errors from each driving system of joints are not part of the closed loop system. Thus, precision positioning depends on wires elastic deformation which is about microns and causes angle deviation of joints about tens of minutes of sexagesimal degrees. The closer the joints to base arm the smaller positioning precision of joint. The obtained results are necessary for further compensation made by electronic corrections in the programming algorithm of the elephant's trunk robotic arm to improve accuracy.

  4. Percutaneous Kirschner wire (K-wire) fixation for humerus shaft ...

    African Journals Online (AJOL)

    In the present study, Kirschner wires (K-wire) were used to achieve a closed intramedullary fixation of humeral shaft fractures. The objective of this study was to evaluate the efficacy of intramedullary K-wires for the treatment of humeral shaft fracture in children. Patients and Methods: This prospective study was conducted in ...

  5. Wiring for space applications program

    Science.gov (United States)

    Hammoud, Ahmad

    1994-01-01

    The insulation testing and analysis consists of: identifying and prioritizing NASA wiring requirements; selecting candidate wiring constructions; developing test matrix and formulating test program; managing, coordinating, and conducting tests; and analyzing and documenting data, establishing guidelines and recommendations.

  6. Challenges in the implementation of an electronic surveillance system in a resource-limited setting: Alerta, in Peru

    Directory of Open Access Journals (Sweden)

    Soto Giselle

    2008-11-01

    Full Text Available Abstract Background Infectious disease surveillance is a primary public health function in resource-limited settings. In 2003, an electronic disease surveillance system (Alerta was established in the Peruvian Navy with support from the U.S. Naval Medical Research Center Detachment (NMRCD. Many challenges arose during the implementation process, and a variety of solutions were applied. The purpose of this paper is to identify and discuss these issues. Methods This is a retrospective description of the Alerta implementation. After a thoughtful evaluation according to the Centers for Disease Control and Prevention (CDC guidelines, the main challenges to implementation were identified and solutions were devised in the context of a resource-limited setting, Peru. Results After four years of operation, we have identified a number of challenges in implementing and operating this electronic disease surveillance system. These can be divided into the following categories: (1 issues with personnel and stakeholders; (2 issues with resources in a developing setting; (3 issues with processes involved in the collection of data and operation of the system; and (4 issues with organization at the central hub. Some of the challenges are unique to resource-limited settings, but many are applicable for any surveillance system. For each of these challenges, we developed feasible solutions that are discussed. Conclusion There are many challenges to overcome when implementing an electronic disease surveillance system, not only related to technology issues. A comprehensive approach is required for success, including: technical support, personnel management, effective training, and cultural sensitivity in order to assure the effective deployment of an electronic disease surveillance system.

  7. Electronic properties of quasi one-dimensional quantum wire models under equal coupling strength superpositions of Rashba and Dresselhaus spin-orbit interactions in the presence of an in-plane magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Papp, E. [Physics Department, West University of Timisoara, RO-300223, Timisoara (Romania); Micu, C.; Racolta, D. [Faculty of Science, North University of Baia Mare, RO-430122, Baia Mare (Romania)

    2013-11-13

    In this paper one deals with the theoretical derivation of energy bands and of related wavefunctions characterizing quasi 1D semiconductor heterostructures, such as InAs quantum wire models. Such models get characterized this time by equal coupling strength superpositions of Rashba and Dresselhaus spin-orbit interactions of dimensionless magnitude a under the influence of in-plane magnetic fields of magnitude B. We found that the orientations of the field can be selected by virtue of symmetry requirements. For this purpose one resorts to spin conservations, but alternative conditions providing sensible simplifications of the energy-band formula can be reasonably accounted for. Besides the wavenumber k relying on the 1D electron, one deals with the spin-like s=±1 factors in the front of the square root term of the energy. Having obtained the spinorial wavefunction, opens the way to the derivation of spin precession effects. For this purpose one resorts to the projections of the wavenumber operator on complementary spin states. Such projections are responsible for related displacements proceeding along the Ox-axis. This results in a 2D rotation matrix providing both the precession angle as well as the precession axis.

  8. Debate: Wired versus Wireless.

    Science.gov (United States)

    Meeks, Glenn; Nair, Prakash

    2000-01-01

    Debates the issue of investing in wiring schools for desktop computer networks versus using laptops and wireless networks. Included are cost considerations and the value of technology for learning. Suggestions include using wireless networks for existing schools, hardwiring computers for new construction, and not using computers for elementary…

  9. Wired vs. Wireless.

    Science.gov (United States)

    Fielding, Randall

    2000-01-01

    Presents a debate on which technology will be in tomorrow's classrooms and the pros and cons of wiring classrooms and using a wireless network. Concluding comments address the likelihood, and desirability, of placing computers throughout the entire educational process and what types of computers and capabilities are needed. (GR)

  10. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...

  11. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and have...

  12. RESEARCH OF INFLUENCE OF QUALITY OF ELECTRONIC EDUCATIONAL RESOURCES ON QUALITY OF TRAINING WITH USE OF DISTANCE TECHNOLOGIES

    Directory of Open Access Journals (Sweden)

    H. M. Kravtsov

    2013-03-01

    Full Text Available Communication improving of educational processes requires today new approaches to the management arrangements and forming of educational policy in the field of distance learning, which is based on the use of modern information and communication technologies. An important step in this process is the continuous monitoring of the development and implementation of information technology and, in particular, the distance learning systems in higher educational establishments. The main objective of the monitoring is the impact assessment on the development of distance learning following the state educational standards, curricula, methodical and technical equipment and other factors; factors revelation that influence the implementation and outcomes of distance learning; results comparison of educational institution functioning and distance education systems in order to determine the most efficient ways of its development. The paper presents the analysis results of the dependence of the quality of educational services on the electronic educational resources. Trends in educational services development was studied by comparing the quality influence of electronic educational resources on the quality of educational services of higher pedagogical educational institutions of Ukraine as of 2009-2010 and 2012-2013. Generally, the analysis of the survey results allows evaluating quality of the modern education services as satisfactory and it can be said that almost 70% of the success of their future development depends on the quality of the used electronic educational resources and distance learning systems in particular.

  13. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  14. Wire EDM for Refractory Materials

    Science.gov (United States)

    Zellars, G. R.; Harris, F. E.; Lowell, C. E.; Pollman, W. M.; Rys, V. J.; Wills, R. J.

    1982-01-01

    In an attempt to reduce fabrication time and costs, Wire Electrical Discharge Machine (Wire EDM) method was investigated as tool for fabricating matched blade roots and disk slots. Eight high-strength nickel-base superalloys were used. Computer-controlled Wire EDM technique provided high quality surfaces with excellent dimensional tolerances. Wire EDM method offers potential for substantial reductions in fabrication costs for "hard to machine" alloys and electrically conductive materials in specific high-precision applications.

  15. Tracking the Flow of Resources in Electronic Waste - The Case of End-of-Life Computer Hard Disk Drives.

    Science.gov (United States)

    Habib, Komal; Parajuly, Keshav; Wenzel, Henrik

    2015-10-20

    Recovery of resources, in particular, metals, from waste flows is widely seen as a prioritized option to reduce their potential supply constraints in the future. The current waste electrical and electronic equipment (WEEE) treatment system is more focused on bulk metals, where the recycling rate of specialty metals, such as rare earths, is negligible compared to their increasing use in modern products, such as electronics. This study investigates the challenges in recovering these resources in the existing WEEE treatment system. It is illustrated by following the material flows of resources in a conventional WEEE treatment plant in Denmark. Computer hard disk drives (HDDs) containing neodymium-iron-boron (NdFeB) magnets were selected as the case product for this experiment. The resulting output fractions were tracked until their final treatment in order to estimate the recovery potential of rare earth elements (REEs) and other resources contained in HDDs. The results further show that out of the 244 kg of HDDs treated, 212 kg comprising mainly of aluminum and steel can be finally recovered from the metallurgic process. The results further demonstrate the complete loss of REEs in the existing shredding-based WEEE treatment processes. Dismantling and separate processing of NdFeB magnets from their end-use products can be a more preferred option over shredding. However, it remains a technological and logistic challenge for the existing system.

  16. 30 CFR 77.515 - Bare signal or control wires; voltage.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Bare signal or control wires; voltage. 77.515 Section 77.515 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE... COAL MINES Electrical Equipment-General § 77.515 Bare signal or control wires; voltage. The voltage on...

  17. HELP (INFORMATION ELECTRONIC RESOURCE "CHRONICLE OF ONU: DATES, FACTS, EVENTS": HISTORY OF UNIVERSITY IN INFORMATION SPACE

    Directory of Open Access Journals (Sweden)

    А. М. Гавриленко

    2016-03-01

    Object of research is the help information resource "The chronicle of the Odessa national university of I. I. Mechnikov: dates, facts, events". The main objective of our article – to state the main methodological bases of creation of information resource. One of advantages of information resource is possibility of continuous updating and replenishment by new information. Main objective of creation of this information resource is systematization of material on stories of the Odessa national university of I. I. Mechnikov from the date of his basis to the present, ensuring interactive access to information on the main dates, the most significant events in life of university. The base of research are sources on the history of university, chronology of historical development, formation of infrastructure, cadres and scientific researches. In information resource the main stages of development, functioning and transformation of the Odessa University are analyzed, information on its divisions is collected. For creation of this information resource in Scientific library the method of work was developed, the main selection criteria of data are allocated. This information resource have practical value for all who is interested in history of university, historians, scientists-researchers of history of science and the city of Odessa.

  18. Aircraft wire system laboratory development : phase I progress report.

    Energy Technology Data Exchange (ETDEWEB)

    Dinallo, Michael Anthony; Lopez, Christopher D.

    2003-08-01

    An aircraft wire systems laboratory has been developed to support technical maturation of diagnostic technologies being used in the aviation community for detection of faulty attributes of wiring systems. The design and development rationale of the laboratory is based in part on documented findings published by the aviation community. The main resource at the laboratory is a test bed enclosure that is populated with aged and newly assembled wire harnesses that have known defects. This report provides the test bed design and harness selection rationale, harness assembly and defect fabrication procedures, and descriptions of the laboratory for usage by the aviation community.

  19. Effect of Access to an Electronic Medical Resource on Performance Characteristics of a Certification Examination: A Randomized Controlled Trial.

    Science.gov (United States)

    Lipner, Rebecca S; Brossman, Bradley G; Samonte, Kelli M; Durning, Steven J

    2017-09-05

    Electronic resources are increasingly used in medical practice. Their use during high-stakes certification examinations has been advocated by many experts, but whether doing so would affect the capacity to differentiate between high and low abilities is unknown. To determine the effect of electronic resources on examination performance characteristics. Randomized controlled trial. Medical certification program. 825 physicians initially certified by the American Board of Internal Medicine (ABIM) who passed the Internal Medicine Certification examination or sat for the Internal Medicine Maintenance of Certification (IM-MOC) examination in 2012 to 2015. Participants were randomly assigned to 1 of 4 conditions: closed book using typical or additional time, or open book (that is, UpToDate [Wolters Kluwer]) using typical or additional time. All participants took the same modified version of the IM-MOC examination. Primary outcomes included item difficulty (how easy or difficult the question was), item discrimination (how well the question differentiated between high and low abilities), and average question response time. Secondary outcomes included examination dimensionality (that is, the number of factors measured) and test-taking strategy. Item response theory was used to calculate question characteristics. Analysis of variance compared differences among conditions. Closed-book conditions took significantly less time than open-book conditions (mean, 79.2 seconds [95% CI, 78.5 to 79.9 seconds] vs. 110.3 seconds [CI, 109.2 to 111.4 seconds] per question). Mean discrimination was statistically significantly higher for open-book conditions (0.34 [CI, 0.32 to 0.35] vs. 0.39 [CI, 0.37 to 0.41] per question). A strong single dimension showed that the examination measured the same factor with or without the resource. Only 1 electronic resource was evaluated. Inclusion of an electronic resource with time constraints did not adversely affect test performance and did not change

  20. Development of the Cylindrical Wire Electrical Discharge Machining Process.

    Energy Technology Data Exchange (ETDEWEB)

    McSpadden, SB

    2002-01-22

    Results of applying the wire Electrical Discharge Machining (EDM) process to generate precise cylindrical forms on hard, difficult-to-machine materials are presented. A precise, flexible, and corrosion-resistant underwater rotary spindle was designed and added to a conventional two-axis wire EDM machine to enable the generation of free-form cylindrical geometries. A detailed spindle error analysis identifies the major source of error at different frequency. The mathematical model for the material removal of cylindrical wire EDM process is derived. Experiments were conducted to explore the maximum material removal rate for cylindrical and 2D wire EDM of carbide and brass work-materials. Compared to the 2D wire EDM, higher maximum material removal rates may be achieved in the cylindrical wire EDM. This study also investigates the surface integrity and roundness of parts created by the cylindrical wire EDM process. For carbide parts, an arithmetic average surface roughness and roundness as low as 0.68 and 1.7 {micro}m, respectively, can be achieved. Surfaces of the cylindrical EDM parts were examined using Scanning Electron Microscopy (SEM) to identify the craters, sub-surface recast layers and heat-affected zones under various process parameters. This study has demonstrated that the cylindrical wire EDM process parameters can be adjusted to achieve either high material removal rate or good surface integrity.

  1. Building and Managing Electronic Resources in Digital Era in India with Special Reference to IUCAA and NIV, Pune: A Comparative Case Study

    Science.gov (United States)

    Sahu, H. K.; Singh, S. N.

    2015-04-01

    This paper discusses and presents a comparative case study of two libraries in Pune, India, Inter-University Centre for Astronomy and Astrophysics and Information Centre and Library of National Institute of Virology (Indian Council of Medical Research). It compares how both libraries have managed their e-resource collections, including acquisitions, subscriptions, and consortia arrangements, while also developing a collection of their own resources, including pre-prints and publications, video lectures, and other materials in an institutional repository. This study illustrates how difficult it is to manage electronic resources in a developing country like India, even though electronic resources are used more than print resources. Electronic resource management can be daunting, but with a systematic approach, various problems can be solved, and use of the materials will be enhanced.

  2. Implosion dynamics and radiative properties of W planar wire arrays influenced by Al wires on University of Michigan's LTD generator

    Science.gov (United States)

    Safronova, A. S.; Kantsyrev, V. L.; Shlyaptseva, V. V.; Shrestha, I. K.; Butcher, C. J.; Stafford, A.; Campbell, P. C.; Miller, S.; Yager-Elorriaga, D. A.; Jordan, N. M.; McBride, R. D.; Gilgenbach, R. M.

    2017-10-01

    The results of new experiments with W Double Planar Wire Arrays (DPWA) at the University of Michigan's Linear Transformer Driver (LTD) generator are presented that are of particular importance for future work with wire arrays on 40-60 MA LTDs at SNL. A diagnostic set similar to the previous campaigns comprised filtered x-ray diodes, a Faraday cup, x-ray spectrometers and pinhole cameras, but had an ultra-fast 12-frame self-emission imaging system. Implosion and radiative characteristics of two DPWAs of the same mass (60 μg/cm) and geometry (two planes with 8 wires each at the distance of 6 mm and an inter-wire gap of 0.7 mm) with one plane of W wires and another either of W wires (1) or of Al wires (2) were compared in detail. The substantial differences between two cases are observed: 1) precursor formation and intense hard x-ray characteristic emission of W (``cold'' L lines) caused by electron beams; 2) no precursor, standing shocks at the W plane side that lasted up to a hundred of ns, fast ablation and implosion of Al wires, and suppression of hard x-ray ``cold'' L lines of W. In addition, the evolution of self-emission in a broad period of time up to 400 ns is analyzed for the first time. Research supported by NNSA under DOE Grant DE-NA0003047.

  3. Molecular wires, switches and memories

    Science.gov (United States)

    Chen, Jia

    Molecular electronics, an emerging field, makes it possible to build individual molecules capable of performing functions identical or analogous to present- day conductors, switches, or memories. These individual molecules, with a nano-meter scale characteristic length, can be designed and chemically synthesized with specific atoms, geometries and charge distribution. This thesis focuses on the design, and measurements of molecular wires, and related strategically engineered structures-molecular switches and memories. The experimental system relies on a thermodynamically driven self-assembling process to attach molecules onto substrate surfaces without intervention from outside. The following topics will be discussed: directed nanoscale manipulation of self-assembled molecules using scanning tunneling microscope; investigation on through-bond transport of nanoscale symmetric metal/conjugated self- assembled monolayers (SAM)/metal junctions, where non- Ohmic thermionic emission was observed to be the dominant process, with isocyanide-Pd contacts showing the lowest thermionic barrier of 0.22 eV; the first realization of robust and large reversible switching behavior in an electronic device that utilizes molecules containing redox centers as the active component, exhibiting negative differential resistance (NDR) and large on-off peak-to-valley ratio (PVR); observation of erasable storage of higher conductivity states in these redox- center containing molecular devices, and demonstration of a two-terminal electronically programmable and erasable molecular memory cell with long bit retention time.

  4. Antibacterial Modification of Kirschner Wires with Polyluteolin toward Methicillin-Resistant Staphylococcus aureus (MRSA

    Directory of Open Access Journals (Sweden)

    Jialiang Zhu

    2015-07-01

    Full Text Available In this study we report antibacterial modification of Kirschner wires (K-wires with polyluteolin (PL toward methicillin-resistant Staphylococcus aureus (MRSA. K-wires were modified by immersing them in the luteolin-containing aqueous solution for 24 h. Characterizations using scanning electron microscopy and electrochemical methods confirmed the presence of the PL coatings on the K-wires. The PL-coated K-wires were further found to show antibacterial activity toward MRSA and remained unimpaired antibacterial activity even after the steam sterilization treatment.

  5. Command Wire Sensor Measurements

    Science.gov (United States)

    2012-09-01

    NPS anechoic chamber is located in Spanagel Hall, Room 604. Although the chamber was built for instruction purposes only, it can be used for research...thesis is to investigate the wire scattering behavior and clutter characteristics through measurements performed in the NPS anechoic chamber. The...research has successfully resolved the various multipath components within the anechoic chamber. The transmit-receive coupling between the antennas was

  6. Exciton dephasing in ZnSe quantum wires

    DEFF Research Database (Denmark)

    Wagner, Hans Peter; Langbein, Wolfgang Werner; Hvam, Jørn Märcher

    1998-01-01

    The homogeneous linewidths of excitons in wet-etched ZnSe quantum wires of lateral sizes down to 23 nm are studied by transient four-wave mixing. The low-density dephasing time is found to increase with decreasing wire width. This is attributed mainly to a reduction of electron-exciton scattering......-one-dimensional system, enhancing the repulsive interaction between excitons due to Pauli blocking....

  7. Theory of Spin Seebeck Effects in a Quantum Wire

    Science.gov (United States)

    Ogata, Masao; Fukuyama, Hidetoshi

    2017-09-01

    Spin Seebeck coefficient in a quantum wire is microscopically derived using the Kubo formula and thermal Green’s functions, taking account of the effects of disorder in a self-consistent t-matrix approximation. It is found that the induced spin current to be detected through the inverse spin Hall effect will be in the range of experimental detectability when the chemical potential for electrons in the quantum wire is close to the band edge.

  8. Magnetic properties of iron nanoparticles prepared by exploding wire technique

    OpenAIRE

    Alqudami, Abdullah; Annapoorni, S.; Lamba, Subhalakshmi; Kothari, P C; Kotnala, R K

    2006-01-01

    Nanoparticles of iron were prepared in distilled water using very thin iron wires and sheets, by the electro-exploding wire technique. Transmission electron microscopy reveals the size of the nanoparticles to be in the range 10 to 50 nm. However, particles of different sizes can be segregated by using ultrahigh centrifuge. X-ray diffraction studies confirm the presence of the cubic phase of iron. These iron nanoparticles were found to exhibit fluorescence in the visible region in contrast to ...

  9. Supporting Learning and Information Sharing in Natural Resource Management with Technologies for Electronic Documents

    Science.gov (United States)

    Alem, Leila; McLean, Alistair

    2005-01-01

    Community participation is central to achieving sustainable natural resource management. A prerequisite to informed participation is that community and stakeholder groups have access to different knowledge sources, are more closely attuned to the different issues and viewpoints, and are sufficiently equipped to understand and maybe resolve complex…

  10. MendelWeb: An Electronic Science/Math/History Resource for the WWW.

    Science.gov (United States)

    Blumberg, Roger B.

    This paper describes a hypermedia resource, called MendelWeb that integrates elementary biology, discrete mathematics, and the history of science. MendelWeb is constructed from Gregor Menders 1865 paper, "Experiments in Plant Hybridization". An English translation of Mendel's paper, which is considered to mark the birth of classical and…

  11. Helping Patrons Find Locally Held Electronic Resources: An Interlibrary Loan Perspective

    Science.gov (United States)

    Johnston, Pamela

    2016-01-01

    The University of North Texas Libraries provide extensive online access to academic journals through major vendor databases. As illustrated by interlibrary loan borrowing requests for items held in our databases, patrons often have difficulty navigating the available resources. In this study, the Interlibrary Loan staff used data gathered from the…

  12. QR Codes as Finding Aides: Linking Electronic and Print Library Resources

    Science.gov (United States)

    Kane, Danielle; Schneidewind, Jeff

    2011-01-01

    As part of a focused, methodical, and evaluative approach to emerging technologies, QR codes are one of many new technologies being used by the UC Irvine Libraries. QR codes provide simple connections between print and virtual resources. In summer 2010, a small task force began to investigate how QR codes could be used to provide information and…

  13. Faculty as a community engaged with ongoing curricular development: use of groupware and electronic resources.

    Science.gov (United States)

    Miller, Judy; Koyanagi, Mark; Morgan, Kevin J

    2005-01-01

    This article describes how technology can facilitate faculty engagement in curriculum development, use faculty time efficiently, and ensure program quality. A plan to initiate an accelerated second-degree bachelor of science in nursing option was the impetus for use of groupware electronic strategies to support faculty as valued members of the academic community, engaged in the undergraduate program and its curriculum. This article describes the two Web-based applications (electronic-based strategies) developed: the curriculum development homepage as a collaborative communication tool, and a curricular tracking tool.

  14. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  15. Impact of electronic healthcare-associated infection surveillance software on infection prevention resources: a systematic review of the literature.

    Science.gov (United States)

    Russo, P L; Shaban, R Z; Macbeth, D; Carter, A; Mitchell, B G

    2017-09-08

    Surveillance of healthcare-associated infections is fundamental for infection prevention. The methods and practices for surveillance have evolved as technology becomes more advanced. The availability of electronic surveillance software (ESS) has increased, and yet adoption of ESS is slow. It is argued that ESS delivers savings through automation, particularly in terms of human resourcing and infection prevention (IP) staff time. To describe the findings of a systematic review on the impact of ESS on IP resources. A systematic search was conducted of electronic databases Medline and the Cumulative Index to Nursing and Allied Health Literature published between January 1(st), 2006 and December 31(st), 2016 with analysis using the Newcastle-Ottawa Scale. In all, 2832 articles were reviewed, of which 16 studies met the inclusion criteria. IP resources were identified as time undertaken on surveillance. A reduction in IP staff time to undertake surveillance was demonstrated in 13 studies. The reduction proportion ranged from 12.5% to 98.4% (mean: 73.9%). The remaining three did not allow for any estimation of the effect in terms of IP staff time. None of the studies demonstrated an increase in IP staff time. The results of this review demonstrate that adopting ESS yields considerable dividends in IP staff time relating to data collection and case ascertainment while maintaining high levels of sensitivity and specificity. This has the potential to enable reinvestment into other components of IP to maximize efficient use of scarce IP resources. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. Survey of the use of electronic information resources by students in ...

    African Journals Online (AJOL)

    For libraries to continue to lead in this industry generally and academic libraries in particular, deliberate effort must be made to bring the IT education to every potential user of the libraries. This however must be done based on available data. This is what this study sought to provide- a survey of the use of electronic ...

  17. Data Resource Profile: Cardiovascular disease research using linked bespoke studies and electronic health records (CALIBER)

    Science.gov (United States)

    Denaxas, Spiros C; George, Julie; Herrett, Emily; Shah, Anoop D; Kalra, Dipak; Hingorani, Aroon D; Kivimaki, Mika; Timmis, Adam D; Smeeth, Liam; Hemingway, Harry

    2012-01-01

    The goal of cardiovascular disease (CVD) research using linked bespoke studies and electronic health records (CALIBER) is to provide evidence to inform health care and public health policy for CVDs across different stages of translation, from discovery, through evaluation in trials to implementation, where linkages to electronic health records provide new scientific opportunities. The initial approach of the CALIBER programme is characterized as follows: (i) Linkages of multiple electronic heath record sources: examples include linkages between the longitudinal primary care data from the Clinical Practice Research Datalink, the national registry of acute coronary syndromes (Myocardial Ischaemia National Audit Project), hospitalization and procedure data from Hospital Episode Statistics and cause-specific mortality and social deprivation data from the Office of National Statistics. Current cohort analyses involve a million people in initially healthy populations and disease registries with ∼105 patients. (ii) Linkages of bespoke investigator-led cohort studies (e.g. UK Biobank) to registry data (e.g. Myocardial Ischaemia National Audit Project), providing new means of ascertaining, validating and phenotyping disease. (iii) A common data model in which routine electronic health record data are made research ready, and sharable, by defining and curating with meta-data >300 variables (categorical, continuous, event) on risk factors, CVDs and non-cardiovascular comorbidities. (iv) Transparency: all CALIBER studies have an analytic protocol registered in the public domain, and data are available (safe haven model) for use subject to approvals. For more information, e-mail s.denaxas@ucl.ac.uk PMID:23220717

  18. Electronic Resources in a Next-Generation Catalog: The Case of WorldCat Local

    Science.gov (United States)

    Shadle, Steve

    2009-01-01

    In April 2007, the University of Washington Libraries debuted WorldCat Local (WCL), a localized version of the WorldCat database that interoperates with a library's integrated library system and fulfillment services to provide a single-search interface for a library's physical and electronic content. This brief will describe how WCL incorporates a…

  19. Use of electronic medical records and biomarkers to manage risk and resource efficiencies

    NARCIS (Netherlands)

    Ryan, Dermot; Blakey, John; Chisholm, Alison; Price, David; Thomas, Mike; Ställberg, Björn; Lisspers, Karin; Kocks, Janwillem W H

    2017-01-01

    The migration from paper to electronic medical records (EMRs) was motivated by the administrative need to record, retrieve and process increasing amounts of clinical data in the 1980s. In the intervening period, there has been growing recognition of the potential of such records for achieving care

  20. Absorbed Dose Distributions in Irradiated Plastic Tubing and Wire Insulation

    DEFF Research Database (Denmark)

    Miller, Arne; McLaughlin, W. L.

    1979-01-01

    Plastic tubing and wire insulation were simulated by radiochromic dye dosimeter films having electron absorbing properties similar to the materials of interest (polyethylene and PVC). A 400-keV electron accelerator was used to irradiate from 1, 2, 3 and 4 sides simulating possible industrial...

  1. Development and use of the professional orientation component of electronic educational resources in the context of a competence-based approach

    OpenAIRE

    Belnitskaya Elena Aleksandrovna

    2015-01-01

    The article deals with the issue of professional orientation of pupils through academic subjects in the information society. The development and use of electronic educational resources for training and professional orientation of pupils are considered in the competence approach context.

  2. Wire grid polarizers for visible wavelengths

    Science.gov (United States)

    Johnson, Joshua Hans

    Detailed analysis of wire-grid (WG) polarizers for visible wavelengths is presented. Rigorous coupled-wave analysis (RCWA) is used to model their performance. The optimum choice of metal for the wires is identified, and the effects of different substrate indices of refraction are considered. The polarization properties are considered with changes in the physical parameters, including period, duty cycle, and wire thickness. It is shown that the performance of WG polarizers improves with increasing angle of incidence. The effect of non-square wire profiles is considered, as is the effect of adding additional dielectric layers between the wires and the substrate. The effect of metal oxide layers forming on the wires is also modeled. While most of this work concerns WG polarizers used in transmission, the performance in reflection is also discussed. Several visible-wavelength WG polarizers were fabricated at the Cornell Nanofabrication Facility (CNF) in Ithaca, NY. Electron-beam lithography was used to write the patterns for these devices, and two different methods of pattern transfer were compared. These were the lift-off method and reactive-ion etching (RIE). We found that lift-off could not produce wires thick enough for good polarization properties. RIE could produce much thicker wires with good profiles and was used for all of the experimental work presented here. Two different methods for metal film deposition, evaporation and sputtering were also compared. Films deposited by sputtering were found to have much lower indices of refraction and to not respond to etching as well. Thermally evaporated films performed much better in WG polarizers. Alternative methods for the mass-production of visible-wavelength WG polarizers are also discussed. The performance of the fabricated WG polarizers is compared to theory. When the measured physical parameters are used in RCWA to predict the performance, the measured extinction ratio is found to be much lower than the

  3. The Global Open Knowledgebase (GOKb: open linked data supporting electronic resources management and scholarly communication

    Directory of Open Access Journals (Sweden)

    Kristin Antelman

    2015-03-01

    Full Text Available The Global Open Knowledgebase (GOKb, a partnership between Kuali OLE and Jisc, is an open data repository of information related to e-resources as they are acquired and managed by libraries. Because GOKb tracks change over time – titles, publishers, packages – and can be used to populate other tools with data, it is changing the way that libraries think about the knowledge base. Propagation of authoritative and enhanced data about e-resources has the potential to benefit all actors in the supply chain from publishers to libraries. GOKb can also serve as a platform to explore how open knowledge base data can contribute to the broader scholarly community infrastructure, particularly around open access (OA.

  4. Reduction in wire tension caused by wire clamping and wire tensioner removal: an experimental Ilizarov frame study.

    Science.gov (United States)

    La Russa, Valentina; Skallerud, Bjørn; Klaksvik, Jomar; Foss, Olav A

    2011-03-01

    The stability of an external ring fixator mainly depends on wire tension. Wire fixators should maintain the tension during both wire clamping to the ring and removal of the tensioner device. In the present study the loss in wire tension related to fixator clamping and wire tensioner removal using three different wire fixator designs was studied. The fixators were based on two different cannulated bolts and a washer. Effects from two different pretension levels in combination with three different bolt torque levels upon loss in wire tension were described. Emitted wire vibration frequency was used to assess the corresponding wire tension. Wire tension was determined after each wire fixator tightening and after the removal of the wire tensioner. Increased bolt torque led to a small decrease in tension for both pretension levels. A considerable higher tension loss was measured when removing the wire tensioner. In all cases, the combination of a new cannulated bolt and a washer maintained the highest tension.

  5. Developing and testing an electronic literacy resource for Arab patients before experiencing radiology procedures.

    Science.gov (United States)

    Abuzaid, Mohamed M; Alnuaimi, Aishah M; Abdi, Asma M; Mohajer, Elika A; Mohamed, Ifrah A; Bilwani, Rawan A; Alhammadi, Shaima B

    2016-09-01

    Radiological examinations require prior preparation that patients should be informed about. Radiologists and radiologic technologists have limited time and resources to do so. Therefore, the internet is a valuable and accessible resource for patient education, but the information may not be reliable, especially that in Arabic language. This study aimed to develop online patient education resources about imaging procedures in Arabic. It also evaluated the understandability and actionability of the source materials. The study was conducted at the University of Sharjah between October 2014 and July 2015. A website containing texts and audiovisuals for 21 medical imaging procedures was created. Bilingual (Arabic and English) radiology experts evaluated the materials with automatic score calculation using the Patient Education Materials Assessment Tool. Two procedures were pilot tested by one evaluator, followed by completion of 28 evaluations by 15 selected experts. Nineteen of 21 procedures were randomly evaluated. For printable materials, the mean understandability score was 92.37 (SD=8.355) and actionability score was 92.11 (SD=13.157). For audiovisual materials, the mean understandability score was 97.63 (SD=13.157) and the percentage for all actionability scores was 100%. The minimum acceptable percentage is 70%. The high percentages scored for the online materials indicate that the evaluators were satisfied with the materials included and that the information would be easy for patients to understand and follow. The higher scores for the audiovisual materials indicate that they were considered more effective for improving patient knowledge patient knowledge.

  6. Health care's most wired. A wired exchange.

    Science.gov (United States)

    Solovy, Alden

    2004-08-01

    There was a time when innovation in health care information technology meant being at the cutting edge of managerial systems. Hospitals made significant investments in financially oriented technology. In the past five years, the investment in clinical IT appears to have outstripped the investment in managerial systems, including enterprise resource planning aimed at improving the supply chain.

  7. Review of wire chamber aging

    Energy Technology Data Exchange (ETDEWEB)

    Va' Vra, J.

    1986-02-01

    This paper makes an overview of the wire chamber aging problems as a function of various chamber design parameters. It emphasizes the chemistry point of view and many examples are drawn from the plasma chemistry field as a guidance for a possible effort in the wire chamber field. The paper emphasizes the necessity of variable tuning, the importance of purity of the wire chamber environment, as well as it provides a practical list of presently known recommendations. In addition, several models of the wire chamber aging are qualitatively discussed. The paper is based on a summary talk given at the Wire Chamber Aging Workshop held at LBL, Berkeley on January 16-17, 1986. Presented also at Wire Chamber Conference, Vienna, February 25-28, 1986. 74 refs., 18 figs., 11 tabs.

  8. Development of a portable and fast wire tension measurement system for MWPC construction

    Science.gov (United States)

    Pan, Jing-Hui; Ma, Chang-Li; Gong, Xue-Yu; Sun, Zhi-Jia; Wang, Yan-Feng; Yin, Chen-Yan; Gong, Lei

    2016-09-01

    In a multi-wire proportional chamber detector (MWPC), the anode and signal wires must maintain suitable tension, which is very important for the detector’s stable and accurate performance. As a result, wire tension control and measurement is essential in MWPC construction. A high pressure 3He MWPC detector is to be used as the thermal neutron detector of the multi-functional reflectometer at China Spallation Neutron Source, and in the construction of the detector, we have developed a wire tension measurement system. This system is accurate, portable and time-saving. With it, the wire tension on an anode wire plane has been tested. The measurement results show that the wire tension control techniques used in detector manufacture are reliable. Supported by National Natural Science Foundation of China (A050506), State Key Laboratory of Particle Detection and Electronics and Key Laboratory of China Academy of Engineering Physics (Y490KF40HD)

  9. Ablation dynamics in coiled wire-array Z-pinches

    Energy Technology Data Exchange (ETDEWEB)

    Hall, G. N.; Lebedev, S. V.; Suzuki-Vidal, F.; Swadling, G.; Chittenden, J. P.; Bland, S. N.; Harvey-Thompson, A. [Blackett Laboratory, Imperial College, London SW7 2BW (United Kingdom); Knapp, P. F.; Blesener, I. C.; McBride, R. D.; Chalenski, D. A.; Blesener, K. S.; Greenly, J. B.; Pikuz, S. A.; Shelkovenko, T. A.; Hammer, D. A.; Kusse, B. R. [Laboratory of Plasma Studies, Cornell University, 439 Rhodes Hall, Ithaca, New York 14853 (United States)

    2013-02-15

    Experiments to study the ablation dynamics of coiled wire arrays were performed on the MAGPIE generator (1 MA, 240 ns) at Imperial College, and on the COBRA generator at Cornell University's Laboratory of Plasma Studies (1 MA, 100 ns). The MAGPIE generator was used to drive coiled wires in an inverse array configuration to study the distribution of ablated plasma. Using interferometry to study the plasma distribution during the ablation phase, absolute quantitative measurements of electron line density demonstrated very high density contrasts between coiled ablation streams and inter-stream regions many millimetres from the wire. The measured density contrasts for a coiled array were many times greater than that observed for a conventional array with straight wires, indicating that a much greater axial modulation of the ablated plasma may be responsible for the unique implosion dynamics of coiled arrays. Experiments on the COBRA generator were used to study the complex redirection of plasma around a coiled wire that gives rise to the ablation structure exhibited by coiled arrays. Observations of this complex 3D plasma structure were used to validate the current model of coiled array ablation dynamics [Hall et al., Phys. Rev. Lett. 100, 065003 (2008)], demonstrating irrefutably that plasma flow from the wires behaves as predicted. Coiled wires were observed to ablate and implode in the same manner on both machines, indicating that current rise time should not be an issue for the scaling of coiled arrays to larger machines with fast current rise times.

  10. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  11. An Exploratory study on the use of LibAnswers to Resolve, Track and Monitor Electronic Resources Issues: The KAUST Library experience

    KAUST Repository

    Ramli, Rindra M.

    2017-05-03

    An Exploratory study on KAUST library use of LibAnswers in resolving electronic resources questions received in LibAnswers. It describes the findings of the questions received in LibAnswers. The author made suggestions based on the findings to improve the reference services in responding to e-resources questions.

  12. Preference and Use of Electronic Information and Resources by Blind/Visually Impaired in NCR Libraries in India

    Directory of Open Access Journals (Sweden)

    Shailendra Kumar

    2013-06-01

    Full Text Available This paper aims to determine the preference and use of electronic information and resources by blind/visually impaired users in the leading National Capital Region (NCR libraries of India. Survey methodology has been used as the basic research tool for data collection with the help of questionnaires. The 125 in total users surveyed in all the five libraries were selected randomly on the basis of willingness of the users with experience of working in digital environments to participate in the survey. The survey results were tabulated and analyzed with descriptive statistics methods using Excel software and 'Stata version 11'. The findings reveal that ICT have a positive impact in the lives of people with disabilities as it helps them to work independently and increases the level of confidence among them. The Internet is the most preferred medium of access to information among the majority of blind/visually impaired users. The 'Complexity of content available on the net' is found as the major challenge faced during Internet use by blind users of NCR libraries. 'Audio books on CDs/DVDs and DAISY books' are the most preferred electronic resources among the majority of blind/visually impaired users. This study will help the library professionals and organizations/institutions serving people with disabilities to develop effective library services for blind/visually impaired users in the digital environment on the basis of findings on information usage behavior in the study.

  13. Superconductivity in quantum wires: A symmetry analysis

    Science.gov (United States)

    Samokhin, K. V.

    2017-10-01

    We study properties of quantum wires with spin-orbit coupling and time reversal symmetry breaking, in normal and superconducting states. Electronic band structures are classified according to quasi-one-dimensional magnetic point groups, or magnetic classes. The latter belong to one of three distinct types, depending on the way the time reversal operation appears in the group elements. The superconducting gap functions are constructed using antiunitary operations and have different symmetry properties depending on the type of the magnetic point group. We obtain the spectrum of the Andreev boundary modes near the end of the wire in a model-independent way, using the semiclassical approach with the boundary conditions described by a phenomenological scattering matrix. Explicit expressions for the bulk topological invariants controlling the number of the boundary zero modes are presented in the general multiband case for two types of the magnetic point groups with real order parameters, corresponding to DIII and BDI symmetry classes.

  14. Internet and electronic resources for inflammatory bowel disease: a primer for providers and patients.

    Science.gov (United States)

    Fortinsky, Kyle J; Fournier, Marc R; Benchimol, Eric I

    2012-06-01

    Patients with inflammatory bowel disease (IBD) are increasingly turning to the Internet to research their condition and engage in discourse on their experiences. This has resulted in new dynamics in the relationship between providers and their patients, with misinformation and advertising potentially presenting barriers to the cooperative patient-provider partnership. This article addresses important issues of online IBD-related health information and social media activity, such as quality, reliability, objectivity, and privacy. We reviewed the medical literature on the quality of online information provided to IBD patients, and summarized the most commonly accessed Websites related to IBD. We also assessed the activity on popular social media sites (such as Facebook, Twitter, and YouTube), and evaluated currently available applications for use by IBD patients and providers on mobile phones and tablets. Through our review of the literature and currently available resources, we developed a list of recommended online resources to strengthen patient participation in their care by providing reliable, comprehensive educational material. Copyright © 2011 Crohn's & Colitis Foundation of America, Inc.

  15. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  16. Radiative Properties of Implosions of Stainless Steel Wire Arrays with Application to Astrophysics

    Science.gov (United States)

    Safronova, A. S.; Ouart, N. D.; Kantsyrev, V. L.; Esaulov, A. A.; Safronova, U. I.; Williamson, K. M.; Shrestha, I.; Coverdale, C. A.; Jones, B.; Deeney, C.

    2009-01-01

    Experiments with different stainless steel (SS) wire loads were performed on the 1 MA Zebra Z-pinch generator at University of Nevada, Reno. The wire array loads consisted of 7.6 μm SS wires and had 10 wires for the planar wire array with an interwire gap of 1 mm and 8 wires for the cylindrical wire array of a 16 mm diameter. In addition, a single-wire experiment with a 25 μm SS wire was carried out. The different wire loads were used to provide a broader spectrum of plasma conditions. Time-integrated and time-gated x-ray images, as well as time-integrated, spatially-resolved and spatially-integrated x-ray spectra, were collected and analyzed. Both K-shell and L-shell radiation were recorded using LiF and KAP crystal spectrometers, respectively. Non-LTE kinetic models of Fe and Ni are employed to derive plasma parameters. For axially resolved L-shell spectra, the resulting electron temperatures are between 230 and 300 eV (higher near the cathode) and electron densities vary from 1019 to 1020 cm-3 dependent on the load. The advantage of using Z-pinch plasmas for astrophysical applications is highlighted.

  17. Fiber vs Rolling Texture: Stress State Dependence for Cold-Drawn Wire

    Science.gov (United States)

    Zorina, M. A.; Karabanalov, M. S.; Stepanov, S. I.; Demakov, S. L.; Loginov, Yu. N.; Lobanov, M. L.

    2018-02-01

    The texture of the cold-drawn copper wire was investigated along the radius using electron backscatter diffraction. The complex fiber texture of the central region of the wire was considered as the rolling texture consisting of a set of preferred orientations. The texture of the periphery region was revealed to be similar to the shear texture. The orientation-dependent properties of the wire were proven to be determined by the texture of the near-surface layers.

  18. Fiber vs Rolling Texture: Stress State Dependence for Cold-Drawn Wire

    Science.gov (United States)

    Zorina, M. A.; Karabanalov, M. S.; Stepanov, S. I.; Demakov, S. L.; Loginov, Yu. N.; Lobanov, M. L.

    2017-12-01

    The texture of the cold-drawn copper wire was investigated along the radius using electron backscatter diffraction. The complex fiber texture of the central region of the wire was considered as the rolling texture consisting of a set of preferred orientations. The texture of the periphery region was revealed to be similar to the shear texture. The orientation-dependent properties of the wire were proven to be determined by the texture of the near-surface layers.

  19. Copper Refinement from Anode to Cathode and then to Wire Rod: Effects of Impurities on Recrystallization Kinetics and Wire Ductility.

    Science.gov (United States)

    Helbert, Anne-Laure; Moya, Alice; Jil, Tomas; Andrieux, Michel; Ignat, Michel; Brisset, François; Baudin, Thierry

    2015-10-01

    In this paper, the traceability of copper from the anode to the cathode and then the wire rod has been studied in terms of impurity content, microstructure, texture, recrystallization kinetics, and ductility. These characterizations were obtained based on secondary ion mass spectrometry, differential scanning calorimetry (DSC), X-ray diffraction, HV hardness, and electron backscattered diffraction. It is shown that the recrystallization was delayed by the total amount of impurities. From tensile tests performed on cold drawn and subsequently annealed wires for a given time, a simplified model has been developed to link tensile elongation to the chemical composition. This model allowed quantification of the contribution of some additional elements, present in small quantity, on the recrystallization kinetics. The proposed model adjusted for the cold-drawn wires was also validated on both the cathode and wire rod used for the study of traceability.

  20. Most Wired 2006: measuring value.

    Science.gov (United States)

    Solovy, Alden

    2006-07-01

    As the Most Wired hospitals incorporate information technology into their strategic plans, they combine a"balanced scorecard"approach with classic business analytics to measure how well IT delivers on their goals. To find out which organizations made this year's 100 Most Wired list, as well as those named in other survey categories, go to the foldout section.

  1. Vibration Measurements of the Wire Scanner for the SwissFEL

    Science.gov (United States)

    Mohanmurthy, Prajwal; Orlandi, Gian Luca; Ischebeck, Rasmus

    2012-10-01

    The SwissFEL is an X-Ray (0.1nm-7nm) Free Electron Laser user facility which is being planned for the Paul Scherrer Institute in Switzerland. At the SwissFEL, view screens will be used to monitor the transverse profile of the electron beam. Wire scanners are also to be employed as the high beam densities of the electron beam will hamper the standard diagnostics. Wire scanners will be tested on the 250MeV SwissFEL Injector Test Facility with a 200pC electron beam whose transverse diameter is typically about 100 μm. The portion of the electron beam that is unscattered from the wire will be measured to determine the beam loss. The wire scanner is driven by a stepper motor and the wire position is obtained using a digital encoder. The wire scanner may be susceptible to vibrations which may lead to erroneous encoder positions. The variation in position of the wire, with the motor being driven at a number of different speeds, was studied using a concentrator back-light and a 1MPixel high speed camera. The camera was triggered using the 10Hz SwissFEL Injector Test Facility timing signal. A typical vibration with an amplitude of about 0.5μm was observed. Dependence of vibration of the wire on the motor driving speed and ways of optimizing the operational parameters.

  2. 30 CFR 56.12069 - Lightning protection for telephone wires and ungrounded conductors.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Lightning protection for telephone wires and... NONMETAL MINES Electricity § 56.12069 Lightning protection for telephone wires and ungrounded conductors... medium on the surface and shall be separated from neutral grounds by a distance of not less than 25 feet. ...

  3. 30 CFR 57.12069 - Lightning protection for telephone wires and ungrounded conductors.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Lightning protection for telephone wires and... AND NONMETAL MINES Electricity Surface Only § 57.12069 Lightning protection for telephone wires and... resistance grounding medium on the surface and shall be separated from neutral grounds by a distance of not...

  4. 30 CFR 77.516 - Electric wiring and equipment; installation and maintenance.

    Science.gov (United States)

    2010-07-01

    ... electrical equipment installed after June 30, 1971, shall meet the requirements of the National Electric Code... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electric wiring and equipment; installation and... OF UNDERGROUND COAL MINES Electrical Equipment-General § 77.516 Electric wiring and equipment...

  5. 30 CFR 77.508 - Lightning arresters, ungrounded and exposed power conductors and telephone wires.

    Science.gov (United States)

    2010-07-01

    ... power conductors and telephone wires. 77.508 Section 77.508 Mineral Resources MINE SAFETY AND HEALTH... AND SURFACE WORK AREAS OF UNDERGROUND COAL MINES Electrical Equipment-General § 77.508 Lightning arresters, ungrounded and exposed power conductors and telephone wires. All ungrounded, exposed power...

  6. Citation Analysis of Engineering Graduate Student Theses Indicates Students Are Using More Electronic Resources

    Directory of Open Access Journals (Sweden)

    Heather MacDonald

    2016-12-01

    Full Text Available A Review of: Becker, D. A., & Chiware, E. R. T. (2015. Citation analysis of masters' theses and doctoral dissertations: Balancing library collections with students' research information needs. Journal of Academic Librarianship, 41(5, 613-620. http://dx.doi.org/10.1016/j.acalib.2015.06.022 Objective – To determine the citation pattern of graduate students’ theses and dissertations. Design – Citation analysis. Setting – An institutional repository at a South African university of technology. Subjects – 201 Engineering Master’s theses and Doctoral dissertations. Methods – A random sample of Master’s theses and Doctoral dissertations from the Faculty of Engineering were analyzed. The theses and dissertations were drawn from the institutional repository covering the period 2005-2014. References were checked for format of the cited items including journal, book, conference proceeding, online item (resource with a URL other than a journal, book or proceeding, and other (anything not in the first four categories. The date of all journal articles was recorded. Journal titles were analyzed in terms of country of origin, language, availability in the library, and online access. Data were categorized by department to determine if there were any differences in the use of materials by department. Data were also analyzed by degree level.

  7. NA48: Wiring up for Change

    CERN Multimedia

    2001-01-01

    The NA48 Collaboration is rebuilding its drift chambers ready for the experiment to start up again this coming July. An intricate task involving the soldering of over 24,000 wires! The future of the NA48 experiment is coming right down to the wire, that is, the wires which the Collaboration is installing in the clean room of Hall 887 on the Prévessin site. Six days a week, technicians are working in shifts to rebuild the experiment's drift chambers. The original chambers were damaged when a section of a vacuum tube imploded at the end of 1999. A year ago, CERN gave the green light for this essential part of the spectrometer to be rebuilt, so the NA48 experiment, which studies CP violation (see box), still has a bright future ahead of it. Three years of data-taking ahead The NA48 experiment aims to penetrate the secrets of CP (Charge Parity) violation. Charge and parity are two parameters which distinguish a particle from an antiparticle. In other words, an electron possesses a negative electric ...

  8. Influence of working gas properties on MWPC anode wire modulation effect

    Science.gov (United States)

    Wang, Xiao-Hu; Chen, Xiao-Qiang

    2015-10-01

    For MWPCs used for X-ray position detection, simulation studies of the anode wire modulation effect of the detector were carried out using the Garfield program. Different gas mixtures were used as the working gas in the simulation, so as to obtain the influence of the X-ray cross section and electron diffusion coefficient of the working gases on the anode wire modulation effect of an MWPC with anode wire spacing of 2 mm. Results show that, though a working gas with higher X-ray cross section implies a larger average drift distance for the ionized electrons, such gas mixtures are of little use in improving the anode wire modulation effect of MWPCs. It is found that the transverse electron diffusion coefficient is the determining factor for the extent of the anode wire modulation effect in the detector. Supported by Scientific Research Fund of Sichuan Provincial Education Department (11ZA140)

  9. Green Supply Chain Collaboration for Fashionable Consumer Electronics Products under Third-Party Power Intervention—A Resource Dependence Perspective

    Directory of Open Access Journals (Sweden)

    Jiuh-Biing Sheu

    2014-05-01

    Full Text Available Under third-party power intervention (TPPI, which increases uncertainty in task environments, complex channel power interplays and restructuring are indispensable among green supply chain members as they move toward sustainable collaborative relationships for increased viability and competitive advantage. From the resource dependence perspective, this work presents a novel conceptual model to investigate the influence of political and social power on channel power restructuring and induced green supply chain collaboration in brander-retailer bidirectional green supply chains of fashionable consumer electronics products (FCEPs. An FCEP refers to the consumer electronics product (e.g., personal computers, mobile phones, computer notebooks, and game consoles with the features of a well-known brand associated, a short product lifecycle, timely and fashionable design fit for market trends, and quick responsiveness to the variations of market demands. The proposed model is tested empirically using questionnaire data obtained from retailers in the FCEP brander-retailer distribution channels. Analytical results reveal that as an extension of political and social power, TPPI positively affects the reciprocal interdependence of dyadic members and reduces power asymmetry, thereby enhancing the collaborative relationship of dyadic members and leading to improved green supply chain performance. Therein, reciprocal interdependence underlying collaborative relationship is the key to reducing the external environmental uncertainties in the TPPI context.

  10. Plasma chemistry in wire chambers

    Energy Technology Data Exchange (ETDEWEB)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an {sup 55}Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed.

  11. The management of online resources and long-term saving of electronic documents by transfer into the digital space

    Directory of Open Access Journals (Sweden)

    Marius Daniel MAREŞ

    2011-12-01

    The electronic archive refers to the electronic storage system, along with the totality of electronic-type stored documents, while using as storage support any environment that can support storing and from which an electronic document can be presented.

  12. The contact conductance on a molecular wire

    Science.gov (United States)

    Stojkovic, S.; Joachim, C.; Grill, L.; Moresco, F.

    2005-06-01

    On a metal-molecule-metal nanojunction, the scanning tunneling microscope (STM) scans at the precise location of the electronic metal-molecule interaction permit a measurement of the contact conductance G0. The conversion curve between the change in the STM contrast Δ h due to this interaction and G0 is presented for a series of conjugated molecular wires. At chemisorption distances, the two-valued character of the G0(Δ h) function is discussed, indicating experimental ways to evaluate G0 as a function of Δ h for different metal-molecule interaction ranges.

  13. Micron-scale laser-wire scanner for the KEK Accelerator Test Facility extraction line

    Directory of Open Access Journals (Sweden)

    Stewart T. Boogert

    2010-12-01

    Full Text Available A laser-wire transverse electron beam size measurement system has been constructed and operated at the Accelerator Test Facility (ATF extraction line at KEK. The construction of the system is described in detail along with the environment of the ATF related to the laser wire. A special set of electron beam optics was developed to generate an approximately 1  μm vertical focus at the laser-wire location. The results of our operation at the ATF extraction line are presented, where a minimum rms electron beam size of 4.8±0.3  μm was measured, and smaller electron beam sizes can be measured by developing the method further. The beam size at the laser-wire location was changed using quadrupoles and the resulting electron beam size measured, and vertical emittance extracted.

  14. Effect of thickness of insulation coating on temperature of electrically exploded tungsten wires in vacuum

    Science.gov (United States)

    Shi, Huantong; Zou, Xiaobing; Wang, Xinxin

    2017-07-01

    This paper reports an interesting observation of great differences in the temperature of exploded wires with insulation coating of different thicknesses. Two kinds of polyimide-coated tungsten wires were used with the same conductive diameter 12.5 μm but a different thickness of coating, 0.75-2.25 μm and 2.25-4.25 μm, respectively. The specific energy reconstructed from the current and voltage signals was quite close for the tested wires. However, the exploding scenario, obtained from Mach-Zehnder interferograms, showed great differences: a neutral outer-layer was observed around the thick-coated wire, which was absent for the thin-coated wire; and the calculated electron density and local thermal equilibrium temperature were much higher for thick-coated wires. The heat-preserving neutral layer formed by the decomposition of the insulation was supposed to be the cause of this phenomenon.

  15. Variation in corrosion resistance of nickel-titanium wires from different manufacturers.

    Science.gov (United States)

    Huang, Her-Hsiung

    2005-07-01

    Nickel-titanium (NiTi) wires produced by various manufacturers may have different corrosion resistance in acidic oral environments. The purpose of this study was to investigate the variation during in vitro corrosion resistance of commercial NiTi dental orthodontic wires from different manufacturers using the fast electrochemical technique. The linear polarization test was used to evaluate the corrosion resistance, in terms of polarization resistance (Rp), of as-received commercial NiTi wires in acidic artificial saliva at 37 degrees C. One-way analysis of variance was used to analyze Rp with the wire manufacturer as the variable factor. Atomic force microscopy was used to analyze the three-dimensional surface topography and roughness (Ra). Electron spectroscopy for chemical analysis was used to identify the chemical structure of the passive film on the NiTi wires. The results showed that NiTi wires from different manufacturers had a statistically significant difference in Rp (P corrosion resistance.

  16. Magnetoresistance peculiarities of bismuth wires in high magnetic field

    Science.gov (United States)

    Condrea, E.; Gilewski, A.; Nicorici, A.

    2016-03-01

    Magnetoresistance measurements of Bi wires performed in the magnetic field oriented along the bisector axis revealed unexpected anomalous peaks in a high magnetic field far above the quantum limit of the electrons. By combining a magnetic field and an uniaxial strain, we obtained a modification of the electronic structure; as a result, the quantum limit for light and heavy electrons is changed in a different way. For the case where heavy electrons are in the quantum limit, a correlation between the exit of the lowest Landau level of light electrons and the Lifshitz transition was found.

  17. Modeling birds on wires.

    Science.gov (United States)

    Aydoğdu, A; Frasca, P; D'Apice, C; Manzo, R; Thornton, J M; Gachomo, B; Wilson, T; Cheung, B; Tariq, U; Saidel, W; Piccoli, B

    2017-02-21

    In this paper we introduce a mathematical model to study the group dynamics of birds resting on wires. The model is agent-based and postulates attraction-repulsion forces between the interacting birds: the interactions are "topological", in the sense that they involve a given number of neighbors irrespective of their distance. The model is first mathematically analyzed and then simulated to study its main properties: we observe that the model predicts birds to be more widely spaced near the borders of each group. We compare the results from the model with experimental data, derived from the analysis of pictures of pigeons and starlings taken in New Jersey: two different image elaboration protocols allow us to establish a good agreement with the model and to quantify its main parameters. We also discuss the potential handedness of the birds, by analyzing the group organization features and the group dynamics at the arrival of new birds. Finally, we propose a more refined mathematical model that describes landing and departing birds by suitable stochastic processes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Manufacture and quality control of interconnecting wire harnesses

    Science.gov (United States)

    1973-01-01

    Four-volume series of documents has been prepared as standard reference. Each volume may be used separately and covers wire and cable preparation as well as harness fabrication and installation. Series should be useful addition to libraries of manufactures of electrical and electronic equipment.

  19. Analysis of pulsed wire method for field integral measurements in ...

    Indian Academy of Sciences (India)

    of the acoustic wave in the wire could be significant and our analysis provides a method for the evaluation of the magnetic field profile even in such cases taking the effect due to dispersion into account in an exact way. Keywords. Undulator; free-electron laser; synchrotron radiation source; magnetic char- acterization.

  20. High resolution STEM of quantum dots and quantum wires

    DEFF Research Database (Denmark)

    Kadkhodazadeh, Shima

    2013-01-01

    This article reviews the application of high resolution scanning transmission electron microscopy (STEM) to semiconductor quantum dots (QDs) and quantum wires (QWRs). Different imaging and analytical techniques in STEM are introduced and key examples of their application to QDs and QWRs...

  1. Inelastic scattering and local heating in atomic gold wires

    DEFF Research Database (Denmark)

    Frederiksen, Thomas; Brandbyge, Mads; Lorente, N.

    2004-01-01

    We present a method for including inelastic scattering in a first-principles density-functional computational scheme for molecular electronics. As an application, we study two geometries of four-atom gold wires corresponding to two different values of strain and present results for nonlinear...

  2. Charges and Fields in a Current-Carrying Wire

    Science.gov (United States)

    Redzic, Dragan V.

    2012-01-01

    Charges and fields in a straight, infinite, cylindrical wire carrying a steady current are determined in the rest frames of ions and electrons, starting from the standard assumption that the net charge per unit length is zero in the lattice frame and taking into account a self-induced pinch effect. The analysis presented illustrates the mutual…

  3. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  4. Innovative direct energy conversion systems using electronic adiabatic processes of electron fluid in solid conductors: new plants of electrical power and hydrogen gas resources without environmental pollutions

    Energy Technology Data Exchange (ETDEWEB)

    Kondoh, Y.; Kondo, M.; Shimoda, K.; Takahashi, T. [Gunma Univ., Dept. of Electronic Engineering, Kiryu, Gunma (Japan)

    2001-07-01

    It is shown that using a novel recycling process of the environmental thermal energy, innovative permanent auto-working direct energy converter systems (PA-DEC systems) from the environmental thermal to electrical and/or chemical potential (TE/CP) energies, abbreviated as PA-TE/CP-DEC systems, can be used for new auto-working electrical power plants and the plants of the compressible and conveyable hydrogen gas resources at various regions in the whole world, with contributions to the world peace and the economical development in the south part of the world. It is shown that the same physical mechanism by free electrons and electrical potential determined by temperature in conductors, which include semiconductors, leads to the Peltier effect and the Seebeck one. It is experimentally clarified that the long distance separation between two {pi} type elements of the heat absorption (HAS) and the production one (HPS) of the Peltier effect circuit system or between the higher temperature side (HTS) and the lower one (LTS) of the Seebeck effect circuit one does not change in the whole for the both effects. By using present systems, we do not need to use petrified fuels such as coals, oils, and natural gases in order to decrease the greenhouse effect by the CO{sub 2} surrounding the earth. Furthermore, we do not need plats of nuclear fissions that left radiating wastes, i.e., with no environmental pollutions. The PA-TE/CP-DEC systems can be applicable for several km scale systems to the micro ones, such as the plants of the electrical power, the compact transportable hydrogen gas resources, a large heat energy container, which can be settled at far place from thermal energy absorbing area, the refrigerators, the air conditioners, home electrical apparatuses, and further the computer elements. It is shown that the simplest PA-TE/CP-DEC system can be established by using only the Seebeck effect components and the resolving water ones. It is clarified that the externally

  5. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  6. A Wire-Shaped Supercapacitor in Micrometer Size Based on Fe3O4 Nanosheet Arrays on Fe Wire

    Science.gov (United States)

    Li, Guohong; Li, Ruchun; Zhou, Weijia

    2017-10-01

    One-dimensional (1D, wire- and fiber-shaped) supercapacitors have recently attracted interest due to their roll-up, micrometer size and potential applications in portable or wearable electronics. Herein, a 1D wire-shaped electrode was developed based on Fe3O4 nanosheet arrays connected on the Fe wire, which was prepared via oxidation of Fe wire in 0.1 M KCl solution (pH 3) with O2-rich environment under 70 °C. The obtained Fe3O4 nanosheet arrays displayed a high specific capacitance (20.8 mF cm-1 at 10 mV s-1) and long cycling lifespan (91.7% retention after 2500 cycles). The excellent performance may attribute to the connected nanosheet structure with abundant open spaces and the intimate contact between the Fe3O4 and iron substrate. In addition, a wire-shaped asymmetric supercapacitor was fabricated and had excellent capacitive properties with a high energy density (9 µWh cm-2) at power density of 532.7 µW cm-2 and remarkable long-term cycling performance (99% capacitance retention after 2000 cycles). Considering low cost and earth-abundant electrode material, as well as outstanding electrochemical properties, the assembled supercapacitor will possess enormous potential for practical applications in portable electronic device.[Figure not available: see fulltext.

  7. Development of an electronic medical record based alert for risk of HIV treatment failure in a low-resource setting.

    Directory of Open Access Journals (Sweden)

    Nancy Puttkammer

    Full Text Available The adoption of electronic medical record systems in resource-limited settings can help clinicians monitor patients' adherence to HIV antiretroviral therapy (ART and identify patients at risk of future ART failure, allowing resources to be targeted to those most at risk.Among adult patients enrolled on ART from 2005-2013 at two large, public-sector hospitals in Haiti, ART failure was assessed after 6-12 months on treatment, based on the World Health Organization's immunologic and clinical criteria. We identified models for predicting ART failure based on ART adherence measures and other patient characteristics. We assessed performance of candidate models using area under the receiver operating curve, and validated results using a randomly-split data sample. The selected prediction model was used to generate a risk score, and its ability to differentiate ART failure risk over a 42-month follow-up period was tested using stratified Kaplan Meier survival curves.Among 923 patients with CD4 results available during the period 6-12 months after ART initiation, 196 (21.2% met ART failure criteria. The pharmacy-based proportion of days covered (PDC measure performed best among five possible ART adherence measures at predicting ART failure. Average PDC during the first 6 months on ART was 79.0% among cases of ART failure and 88.6% among cases of non-failure (p<0.01. When additional information including sex, baseline CD4, and duration of enrollment in HIV care prior to ART initiation were added to PDC, the risk score differentiated between those who did and did not meet failure criteria over 42 months following ART initiation.Pharmacy data are most useful for new ART adherence alerts within iSanté. Such alerts offer potential to help clinicians identify patients at high risk of ART failure so that they can be targeted with adherence support interventions, before ART failure occurs.

  8. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  9. First Experimental Results And Improvements On Profile Measurements With The Vibrating Wire Scanner

    CERN Document Server

    Arutunian, S G; Dobrovolski, N M; Mailian, M R; Soghoyan, H E; Vasiniuk, I E

    2003-01-01

    The paper presents the first experimental results of transverse profile scans using a wire scanner based on a vibrating wire (vibrating wire scanner - VWS). The measurements were performed at the injector electron beam (6 nA) of the Yerevan synchrotron. The beam profile information is obtained by measuring the wire natural oscillations that depend on the wire temperature. This first experiments on weak electron beam proved this new method as a very sensitive tool, even suitable for tail measurements. Additional, improvements were tested to overcome some problems connected with signal conditioning and signal transfer in the presence of electromagnetic noise. As a result the noises were neatly separated and reduced. A mathematical method for rejection of distorted data was developed. Experiments with the scanner at the PETRA accelerator at DESY are planned for measurements of beam tails.

  10. Consumer reports [electronic resource

    National Research Council Canada - National Science Library

    1942-01-01

    ... only. A limited number of selected reports, advice on product selection and safety alerts are freely available, as are a five year listing of product recalls, a listing of major consumer product...

  11. Surface Modification and Nanojunction Fabrication with Molecular Metal Wires

    Science.gov (United States)

    2012-12-21

    We thank the National Science Council and the Ministry of Education of the Republic of China for financial support. We are also grateful to Mr Wei...Acknowledgements The authors acknowledge the National Science Council and the Ministry of Education of Taiwan for financial support. References 1 Extended Linear...considered to be potential molecular electronic devices [1]. The general expectation is to transport an electron through the continua of metal wire-like

  12. Electronic Information Resources (EIR Adoption in Private University Libraries: The Moderating Effect of Productivity and Relative Advantage on Perceived Usefulness

    Directory of Open Access Journals (Sweden)

    Izuagbe, Roland

    2016-03-01

    Full Text Available The study tested a hybrid model with constructs drawn from the Technology Acceptance Model (TAM and Diffusion of Innovation (DOI theory in order to examine the moderating effect of productivity and relative advantage (RA on perceived usefulness (PU vis-à-vis electronic information resources (EIR adoption in private university libraries in Ogun and Osun States of Nigeria. The descriptive research design was adopted in the study. The population consisted of 61 (55.0% librarians and 50 (45.0% library officers (totaling 116—100% in Babcock University, Bells University, Covenant University, Bowen University, Oduduwa University, and Redeemer's University. Purposive sampling procedure was adopted after which total enumeration was used since the total population is small. The questionnaire was used for data collection. Of the 116 copies of the questionnaire administered, 111 (95.7% were found usable. The instrument was structured based on a 4-point Likert agreement scale of Strongly Agree, Agree, Disagree, and Strongly Disagree. Data were analyzed using descriptive statistics like tables of frequency counts and percentage. The findings revealed that productivity and relative advantage are significant moderators of perceived usefulness of EIR adoption in private university libraries in Ogun and Osun States, Nigeria.

  13. Gold Wire-networks: Particle Array Guided Evaporation Lithograpy

    KAUST Repository

    Lone, Saifullah

    2015-06-29

    We exploited the combination of dry deposition of monolayer of 2D (two dimensional) templates, lift-up transfer of 2D template onto flat surfaces and evaporation lithography [1] to fabricate gold micro- and submicron size wire networks. The approach relies upon the defect free dry deposition of 2D monolayer of latex particles [2] on patterned silicon template and flat PDMS-substrate to create square centered and honey-comb wire networks respectively. The process is followed by lift-up transfer of 2D latex crystal on glass substrate. Subsequently, a small amount of AuNP-suspension is doped on top of the transferred crystal; the suspension is allowed to spread instantaneously and dried at low temperature. The liquid evaporates uniformly to the direction perpendicular to glass substrate. During evaporation, AuNPs are de-wetted along with the movement of liquid to self-assemble in-between the inter-particle spaces and therefore, giving rise to liquid-bridge networks which upon delayed evaporation, transforms into wire networks. The approach is used to fabricate both micro- and submicron wire-networks by simply changing the template dimensions. One of the prime motives behind this study is to down-scale the existing particle array template-based evaporation lithography process to fabricate connected gold wire networks at both micro- and submicron scale. Secondly, the idea of combining the patterned silicon wafer with lifted latex particle template creates an opportunity to clean and res-use the patterned wafer more often and thereby, saving fabrication time and resources. Finally, we illustrated the validity of this approach by creating an easy and high-speed approach to develop gold wire networks on a flexible substrate with a thin deposited adhesive. These advances will not only serve as a platform to scale up the production, but also demonstrated that the fabrication method can produce metallic wire networks of different scale and onto a variety of substrates.

  14. The module of methodical support in system of electronic educational resources as the innovative element of the modern maintenance of formation

    Directory of Open Access Journals (Sweden)

    Ольга Николаевна Крылова

    2009-06-01

    Full Text Available The article introduces some results of research, which were devoted to evaluation of tearches' mobility to introduce innovations in the contents of education. The author considers innovative potential of modules of the methodical support for system of electronic educational resources.

  15. Charting a Course through CORAL: Texas A&M University Libraries' Experience Implementing an Open-Source Electronic Resources Management System

    Science.gov (United States)

    Hartnett, Eric; Beh, Eugenia; Resnick, Taryn; Ugaz, Ana; Tabacaru, Simona

    2013-01-01

    In 2010, after two previous unsuccessful attempts at electronic resources management system (ERMS) implementation, Texas A&M University (TAMU) Libraries set out once again to find an ERMS that would fit its needs. After surveying the field, TAMU Libraries selected the University of Notre Dame Hesburgh Libraries-developed, open-source ERMS,…

  16. The BRIGHTEN Program: Implementation and Evaluation of a Program to Bridge Resources of an Interdisciplinary Geriatric Health Team via Electronic Networking

    Science.gov (United States)

    Emery, Erin E.; Lapidos, Stan; Eisenstein, Amy R.; Ivan, Iulia I.; Golden, Robyn L.

    2012-01-01

    Purpose: To demonstrate the feasibility of the BRIGHTEN Program (Bridging Resources of an Interdisciplinary Geriatric Health Team via Electronic Networking), an interdisciplinary team intervention for assessing and treating older adults for depression in outpatient primary and specialty medical clinics. The BRIGHTEN team collaborates "virtually"…

  17. Structural Parameters and Strengthening Mechanisms in Cold-Drawn Pearlitic Steel Wires

    OpenAIRE

    Zhang, Xiaodan; Godfrey, Andy; Huang, Xiaoxu; Hansen, Niels

    2012-01-01

    Pearlitic steel wires have a nanoscale structure and a strength which can reach 5 GPa. In order to investigate strengthening mechanisms, structural parameters including interlamellar spacing, dislocation density and cementite decomposition, have been analyzed by transmission electron microscopy and high resolution electron microscopy in wires cold drawn up to a strain of 3.7. Three strengthening mechanisms, namely boundary strengthening, dislocation strengthening and solid solution hardening ...

  18. Optical characterisation of photonic wire and photonic crystal waveguides fabricated using nanoimprint lithography

    DEFF Research Database (Denmark)

    Borel, Peter Ingo; Frandsen, Lars Hagedorn; Lavrinenko, Andrei

    2006-01-01

    We have characterised photonic-crystal and photonic-wire waveguides fabricated by thermal nanoimprint lithography. The structures, with feature sizes down below 20 nm, are benchmarked against similar structures defined by direct electron beam lithography.......We have characterised photonic-crystal and photonic-wire waveguides fabricated by thermal nanoimprint lithography. The structures, with feature sizes down below 20 nm, are benchmarked against similar structures defined by direct electron beam lithography....

  19. Thermite welding of Cu-Nb microcomposite wires

    Energy Technology Data Exchange (ETDEWEB)

    Visniakov, Nikolaj; Mikalauskas, Gediminas; Lukauskaite, Raimonda; Cernasejus, Olegas; Rudzinskas, Vitalijus [Vilnius Gediminas Technical Univ. (Lithuania). Faculty of Mechanics; Skamat, Jelena; Boris, Renata [Vilnius Gediminas Technical Univ. (Lithuania). Inst. of Thermal Insulation

    2017-10-15

    Thermite welding of Cu-Nb microcomposite wires was investigated. Suitable compositions of thermite material and slag were determined from the equation of the exothermic combustion synthesis reaction. The phase compositions of the thermite mixture and slag determined by X-ray diffraction analysis correspond to those assessed from the equation. According to non-destructive radiographic testing, the joint structure does not have welding defects. Microstructural examination of the joint cross-section with scanning electron microscopy showed that the Cu-Nb wire retained its shape and microstructure and only a thin surface layer of wire was melted during welding. The difference in electrical resistances of the conductor and welded joint was below 20 %. The thermite joint can withstand a maximum load equal to 62.5 % of the load-bearing capacity of microcomposite conductor.

  20. Towards functional safety in drive-by-wire vehicles

    CERN Document Server

    Bergmiller, Peter Johannes

    2015-01-01

    This book presents approaches to address key challenges based on a vehicle level view and with a special emphasis on Drive-by-Wire systems. The design and testing of modern vehicle electronics are becoming more and more demanding due to increasing interdependencies among components and the safety criticality of tasks. The development towards Drive-by-Wire functionalities in vehicles with multiple actuators for vehicle control further increases the challenge. The book explicitly takes into account the interactions between components  and aims at bridging the gap between the need to generate additional customer benefits and the effort to achieve functional safety. The book follows a twofold approach: on the one side, it presents a toolchain to support efficient further development of novel functionalities for Drive-by-Wire vehicles. The toolchain comprises appropriate software tools and scaled and full-scale experimental vehicles. On the other side, development towards functionally safe and flexible Drive-by-W...

  1. Helical liquids and Majorana bound states in quantum wires.

    Science.gov (United States)

    Oreg, Yuval; Refael, Gil; von Oppen, Felix

    2010-10-22

    We show that the combination of spin-orbit coupling with a Zeeman field or strong interactions may lead to the formation of a helical electron liquid in single-channel quantum wires, with spin and velocity perfectly correlated. We argue that zero-energy Majorana bound states are formed in various situations when such wires are situated in proximity to a conventional s-wave superconductor. This occurs when the external magnetic field, the superconducting gap, or, most simply, the chemical potential vary along the wire. These Majorana states do not require the presence of a vortex in the system. Experimental consequences of the helical liquid and the Majorana states are also discussed.

  2. Plasma arc torch with coaxial wire feed

    Science.gov (United States)

    Hooper, Frederick M

    2002-01-01

    A plasma arc welding apparatus having a coaxial wire feed. The apparatus includes a plasma arc welding torch, a wire guide disposed coaxially inside of the plasma arc welding torch, and a hollow non-consumable electrode. The coaxial wire guide feeds non-electrified filler wire through the tip of the hollow non-consumable electrode during plasma arc welding. Non-electrified filler wires as small as 0.010 inches can be used. This invention allows precision control of the positioning and feeding of the filler wire during plasma arc welding. Since the non-electrified filler wire is fed coaxially through the center of the plasma arc torch's electrode and nozzle, the wire is automatically aimed at the optimum point in the weld zone. Therefore, there is no need for additional equipment to position and feed the filler wire from the side before or during welding.

  3. Ocular dangers of fencing wire.

    Science.gov (United States)

    McAllum, P; Barnes, R; Dickson, J

    2001-07-27

    To invesitgate the incidence and severity of penetrating eye injuries caused by fencing wire in the Waikato region. We reviewed the case notes for all penetrating eye injuries treated at Waikato Hospital during the past six years. Parameters recorded were patient age and sex, mechanism of injury, initial visual acuity, characteristics of injury, surgery performed and final visual outcome. The incidence of penetrating eye injuries in the Waikato region was 3.8 per 100,000 per year, based on an estimated catchment population of 350,000. We found fencing wire to be the third most common cause of penetrating eye injury, accounting for 8.8% of injuries, behind motor vehicle accidents and hammering which accounted for 26.3% and 20.0% of injuries, respectively. The fencing wire injuries involved men exclusively, with an average age of 41.7 years. Fencing wire injuries had worse presenting visual acuity than other injuries, involved the posterior segment of the eye more frequently and were more likely to develop bacterial endophthalmitis. They also underwent more surgical procedures and were more commonly associated with a poor visual outcome. Fencing wire is an important cause of visual loss in the Waikato region. We hope to raise awareness of its potential ocular dangers and to promote the use of appropriate eye protection.

  4. Joining characteristics of orthodontic wires with laser welding.

    Science.gov (United States)

    Iijima, Masahiro; Brantley, William A; Yuasa, Toshihiro; Muguruma, Takeshi; Kawashima, Isao; Mizoguchi, Itaru

    2008-01-01

    Laser welding 0.016 x 0.022 in. beta-Ti, Ni-Ti, and Co-Cr-Ni orthodontic wires was investigated by measuring joint tensile strength, measuring laser penetration depth, determining metallurgical phases using micro X-ray diffraction (micro-XRD), and examining microstructures with an scanning electron microscope (SEM). Welding was performed from 150 to 230 V. Mean tensile strength for Ni-Ti groups was significantly lower (p Ni was significantly lower than for control specimens joined by silver soldering, it was sufficient for clinical use. The beta-Ti orthodontic wire showed deeper penetration depth from laser welding than the Ni-Ti and Co-Cr-Ni orthodontic wires. Micro-XRD patterns of laser-welded beta-Ti and Ni-Ti obtained 2 mm from the boundary were similar to as-received specimens, indicating that original microstructures were maintained. When output voltages of 190 V and higher were used, most peaks from joint areas disappeared or were much weaker, perhaps because of a directional solidification effect, evidenced by SEM observation of fine striations in welded beta-Ti. Laser welding beta-Ti and Co-Cr-Ni wires may be acceptable clinically, since joints had sufficient strength and metallurgical phases in the original wires were not greatly altered.

  5. Optical probing of exploding wires using schlieren and interferometric imaging.

    Science.gov (United States)

    Romanova, V. M.; Pikuz, S. A.; Shelkovenko, T. A.; Hu, Min; Sinars, D. B.; Kusse, B. R.; Dimant, Ya. S.; Greenly, J. B.; Hummer, D. A.

    1999-11-01

    Optical diagnostics using an Nd:YAG laser (l=532 nm) were used to probe exploding fine wires (7.5-20 mm initial diameter) driven by a sinusoidal 4.5/,kA current pulse (350 ns risetime). Phase transitions from vapor to plasma have been directly observed during the explosion process of various wire materials (Al, Au, etc.). Three simultaneous schlieren channels and 1--3 interferometry channels were used. For some experiments, the schlieren channels were made up of a bright-field iris, a dark-field knife edge, and a dark-field strip block. For other experiments, three bright-field images were made at 10 ns intervals. Interferometry was performed using a new astigmatism-free shearing interferometer based on a double-prism air wedge. The images were made with a 4 ns exposure time at 50--2000 ns after the start of the wire current. Simultaneous X-ray backlighting [1] of the wires enabled reliable interpretation of the optical images, and with a step wedge [2] was used to measure the ion density. Combining the ion density and electron density measurements allowed us to estimate the ionization state of the exploded wire. 1. T.A.Shelkovenko, S.A.Pikuz, A.R.Mingaleev, D.A.Hammer, Rev. Sci. Instrum., 70, 667 (1999). 2. S.A.Pikuz, T.A.Shelkovenko, A.R.Mingaleev, H.Neves, D.A.Hammer, Phys. Plasmas (in press).

  6. Metallurgical characterization of a new nickel-titanium wire for rotary endodontic instruments.

    Science.gov (United States)

    Alapati, Satish B; Brantley, William A; Iijima, Masahiro; Clark, William A T; Kovarik, Libor; Buie, Caesar; Liu, Jie; Ben Johnson, William

    2009-11-01

    A novel thermomechanical processing procedure has been developed that yields a superelastic (SE) nickel-titanium (NiTi) wire (M-Wire) that laboratory testing shows has improved mechanical properties compared with conventional SE austenitic NiTi wires used for manufacture of rotary instruments. The objective of this study was to determine the origin of the improved mechanical properties. Specimens from 2 batches of M-Wire prepared under different processing conditions and from 1 batch of standard-processed SE wire for rotary instruments were examined by scanning transmission electron microscopy, temperature-modulated differential scanning calorimetry, micro-x-ray diffraction, and scanning electron microscopy with x-ray energy-dispersive spectrometric analyses. The processing for M-Wire yields a microstructure containing martensite, that the proportions of NiTi phases depend on processing conditions, and that the microstructure exhibits pronounced evidence of alloy strengthening. The presence of Ti(2)Ni precipitates in both microstructures indicates that M-Wire and the conventional SE wire for rotary instruments are titanium-rich.

  7. Synthesis of chemical vapor deposition graphene on tantalum wire for supercapacitor applications

    Energy Technology Data Exchange (ETDEWEB)

    Li, Mingji, E-mail: limingji@163.com [Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electronics Information Engineering, Tianjin University of Technology, Tianjin 300384 (China); Guo, Wenlong [Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electronics Information Engineering, Tianjin University of Technology, Tianjin 300384 (China); Li, Hongji, E-mail: hongjili@yeah.net [Tianjin Key Laboratory of Organic Solar Cells and Photochemical Conversion, School of Chemistry and Chemical Engineering, Tianjin University of Technology, Tianjin 300384 (China); Xu, Sheng [School of Precision Instrument and Optoelectronics Engineering, Tianjin University, Tianjin 300072 (China); Qu, Changqing; Yang, Baohe [Tianjin Key Laboratory of Film Electronic and Communicate Devices, School of Electronics Information Engineering, Tianjin University of Technology, Tianjin 300384 (China)

    2014-10-30

    Highlights: • The capacitance of graphene/tantalum (Ta) wire electrodes is firstly reported. • Graphene was grown on the Ta surface by hot-filament chemical vapor deposition. • Graphene/Ta wire structure is favorable for fast ion and electron transfer. • The graphene/Ta wire electrode shows high capacitive properties. - Abstract: This paper studies the synthesis and electrochemical characterization of graphene/tantalum (Ta) wires as high-performance electrode material for supercapacitors. Graphene on Ta wires is prepared by the thermal decomposition of methane under various conditions. The graphene nanosheets on the Ta wire surface have an average thickness of 1.3–3.4 nm and consist typically of a few graphene monolayers, and TaC buffer layers form between the graphene and Ta wire. A capacitor structure is fabricated using graphene/Ta wire with a length of 10 mm and a diameter of 0.6 mm as the anode and Pt wire of the same size as the cathode. The electrochemical behavior of the graphene/Ta wires as supercapacitor electrodes is characterized by cyclic voltammetry, galvanostatic charge/discharge, and electrochemical impedance spectroscopy in 1 M Na{sub 2}SO{sub 4} aqueous electrolyte. The as-prepared graphene/Ta electrode has highest capacitance of 345.5 F g{sup −1} at current density of 0.5 A g{sup −1}. The capacitance remains at about 84% after 1000 cycles at 10 A g{sup −1}. The good electrochemical performance of the graphene/Ta wire electrode is attributed to the unique nanostructural configuration, high electrical conductivity, and large specific surface area of the graphene layer. This suggests that graphene/Ta wire electrode materials have potential applications in high-performance energy storage devices.

  8. Emission of energetic protons from relativistic intensity laser interaction with a cone-wire target.

    Science.gov (United States)

    Paradkar, B S; Yabuuchi, T; Sawada, H; Higginson, D P; Link, A; Wei, M S; Stephens, R B; Krasheninnikov, S I; Beg, F N

    2012-11-01

    Emission of energetic protons (maximum energy ∼18 MeV) from the interaction of relativistic intensity laser with a cone-wire target is experimentally measured and numerically simulated with hybrid particle-in-cell code, lsp [D. R. Welch et al., Phys. Plasmas 13, 063105 (2006)]. The protons originate from the wire attached to the cone after the OMEGA EP laser (670 J, 10 ps, 5 × 10^{18} W/cm^{2}) deposits its energy inside the cone. These protons are accelerated from the contaminant layer on the wire surface, and are measured in the radial direction, i.e., in a direction transverse to the wire length. Simulations show that the radial electric field, responsible for the proton acceleration, is excited by three factors, viz., (i) transverse momentum of the relativistic fast electrons beam entering into the wire, (ii) scattering of electrons inside the wire, and (iii) refluxing of escaped electrons by "fountain effect" at the end of the wire. The underlying physics of radial electric field and acceleration of protons is discussed.

  9. 30 CFR 77.902-3 - Attachment of ground conductors and ground check wires to equipment frames; use of separate...

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Attachment of ground conductors and ground check wires to equipment frames; use of separate connections. 77.902-3 Section 77.902-3 Mineral...-Voltage Alternating Current Circuits § 77.902-3 Attachment of ground conductors and ground check wires to...

  10. 30 CFR 75.902-4 - Attachment of ground conductors and ground check wires to equipment frames; use of separate...

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Attachment of ground conductors and ground check wires to equipment frames; use of separate connections. 75.902-4 Section 75.902-4 Mineral... § 75.902-4 Attachment of ground conductors and ground check wires to equipment frames; use of separate...

  11. Subchannel Analysis of Wire Wrapped SCWR Assembly

    National Research Council Canada - National Science Library

    Shan, Jianqiang; Wang, Henan; Liu, Wei; Song, Linxing; Chen, Xuanxiang; Jiang, Yang

    2014-01-01

    .... The HPLWR wire wrapped assembly was analyzed. The results show that: (1) the assembly with wire wrap can obtain a more uniform coolant temperature profile than the grid spaced assembly, which will result in a lower peak cladding temperature; (2...

  12. Crystal-Phase Quantum Wires: One-Dimensional Heterostructures with Atomically Flat Interfaces.

    Science.gov (United States)

    Corfdir, Pierre; Li, Hong; Marquardt, Oliver; Gao, Guanhui; Molas, Maciej R; Zettler, Johannes K; van Treeck, David; Flissikowski, Timur; Potemski, Marek; Draxl, Claudia; Trampert, Achim; Fernández-Garrido, Sergio; Grahn, Holger T; Brandt, Oliver

    2018-01-10

    In semiconductor quantum-wire heterostructures, interface roughness leads to exciton localization and to a radiative decay rate much smaller than that expected for structures with flat interfaces. Here, we uncover the electronic and optical properties of the one-dimensional extended defects that form at the intersection between stacking faults and inversion domain boundaries in GaN nanowires. We show that they act as crystal-phase quantum wires, a novel one-dimensional quantum system with atomically flat interfaces. These quantum wires efficiently capture excitons whose radiative decay gives rise to an optical doublet at 3.36 eV at 4.2 K. The binding energy of excitons confined in crystal-phase quantum wires is measured to be more than twice larger than that of the bulk. As a result of their unprecedented interface quality, these crystal-phase quantum wires constitute a model system for the study of one-dimensional excitons.

  13. The mechatronic design of a fast wire scanner in IHEP U-70 accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Baranov, V.T. [Institute for High Energy Physics in National Research Centre “Kurchatov Institute”, Protvino 142281 (Russian Federation); Makhov, S.S. [Microprivod Ltd., Moscow 111123 (Russian Federation); Savin, D.A.; Terekhov, V.I. [Institute for High Energy Physics in National Research Centre “Kurchatov Institute”, Protvino 142281 (Russian Federation)

    2016-10-11

    This paper presents the mechatronic design of a fast wire scanner based on a servomotor. The design of the wire scanner is motivated by the need to measure the transverse profile of the high power proton and carbon beams at the IHEP U-70 accelerator. This paper formulates the requirements to the fast wire scanner system for the high intensity proton beam at the U-70 accelerator. The results on the design of electro-mechanical device for the wire scanner with a wire traveling speed 10–20 m/s are presented. The solution consists in a brushless servomotor and standard motor control electronics. High radiation levels in the accelerator enclosure dictate the use of a resolver as the position feedback element.

  14. Transparency in nanophotonic quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Singh, Mahi R [Department of Physics and Astronomy, University of Western Ontario, London N6A 3K7 (Canada)

    2009-03-28

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  15. Towards Unconventional Applications of Wire Bonding

    OpenAIRE

    Schröder, Stephan

    2018-01-01

    This thesis presents novel heterogeneous integration approaches of wire materials to fabricated and package MEMS devices by exploring unconventional applications of wire bonding technology. Wire bonding, traditionally endemic in the realm of device packaging to establish electrical die-to-package interconnections, is an attractive back-end technology, offering promising features, such as high throughput, flexibility and placement accuracy. Exploiting the advantages of state-of-the-art wire bo...

  16. Novel Wiring Technologies for Aerospace Applications

    Science.gov (United States)

    Gibson, Tracy L.; Parrish, Lewis M.

    2014-01-01

    Because wire failure in aerospace vehicles could be catastrophic, smart wiring capabilities have been critical for NASA. Through the years, researchers at Kennedy Space Center (KSC) have developed technologies, expertise, and research facilities to meet this need. In addition to aerospace applications, NASA has applied its knowledge of smart wiring, including self-healing materials, to serve the aviation industry. This webinar will discuss the development efforts of several wiring technologies at KSC and provide insight into both current and future research objectives.

  17. Detection of a buried wire with two resistively loaded wire antennas

    NARCIS (Netherlands)

    Vossen, S.H.J.A.; Tijhuis, A.G.; Lepelaars, E.S.A.M.; Zwamborn, A.P.M.

    2002-01-01

    The use of two identical straight thin-wire antennas for the detection of a buried wire is analyzed with the aid of numerical calculations. The buried wire is located below an interface between two homogeneous half-spaces. The detection setup, which is formed by a transmitting and a receiving wire,

  18. One century of Kirschner wires and Kirschner wire insertion techniques : A historical review

    NARCIS (Netherlands)

    Franssen, Bas B. G. M.; Schuurman, Arnold H.; Van der Molen, Aebele Mink; Kon, Moshe

    A century ago, in 1909, Martin Kirschner (1879-942) introduced a smooth pin, presently known as the Kirschner wire (K-wire). The K-wire was initiallly used for skeletal traction and is now currently used for many different goals. The development of the K-wire and its insertion devices were mainly

  19. A simple technique to retrieve broken guide wire transfixing hip joint

    Directory of Open Access Journals (Sweden)

    Daya Krishna

    2015-01-01

    Full Text Available While operating on the hip joint, breaking of guide wire became a challenge for treating orthopedic surgeon. Here we report a simple method of removal, which requires limited resources and does not need sophisticated instrumentation. By using this method, we remove broken guide wire in a patient of sub-trochantric fracture of femur managed by close reduction and internal fixation by proximal femoral nail. During the removal of the guide wire, after placing distal screw in the neck the guide wire comes out with some difficulty in the final view on image intensifier - the guide wire broken and transfixes the hip joint but does not enter the pelvis. After removal of the distal screw, its cannulated drill bit was connected to a T-handle and introduced into the track of distal screw up to the broken distal end of guide wire and slow manual reaming done under C-arm image intensifier to prevent damage to the articular cartilage. This process was repeated three times after cleaning drill bit each time to clear the base of guide wire for grasping its distal end. With the help of Kerryson rounger/grasper, the distal end of the guide wire was grasped and easily removed. The distal screw was placed in its original track and the procedure was completed.

  20. Home and School Technology: Wired versus Wireless.

    Science.gov (United States)

    Van Horn, Royal

    2001-01-01

    Presents results of informal research on smart homes and appliances, structured home wiring, whole-house audio/video distribution, hybrid cable, and wireless networks. Computer network wiring is tricky to install unless all-in-one jacketed cable is used. Wireless phones help installers avoid pre-wiring problems in homes and schools. (MLH)

  1. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL MOTOR CARRIER SAFETY... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems...

  2. Customised 2G HTS wire for applications

    Science.gov (United States)

    Samoilenkov, S.; Molodyk, A.; Lee, S.; Petrykin, V.; Kalitka, V.; Martynova, I.; Makarevich, A.; Markelov, A.; Moyzykh, M.; Blednov, A.

    2016-02-01

    Reproducibility of superconducting properties and suitability for specific applications by means of customised finish are two important attributes required from commercial 2G HTS wire. This paper reviews the consistent performance of SuperOx production 2G HTS wire and describes two novel customisation options: surround polyimide varnish insulation and composite bulk materials assembled with 2G HTS wires soldered together.

  3. [The effects of different welding wires on the mechanical properties of laser welding joints].

    Science.gov (United States)

    Huang, Qing-feng; Zhang, Jian-zhong; Jiang, Wei-dong; Li, Quan; Yu, Jin-xing

    2006-08-01

    To evaluate the mechanical properties and microstructure of laser-welded joints with different welding wires for clinical use of welding wire. The standard tensile test and three-point bending test rods were made from Co-Cr and Ni-Cr alloy, and were laser-welded with different welding wire (commercially welding wire and casting wire). Then the tensile rods were tested for the ultimate tensile strength (UTS), and the bending rods for the ultimate bending strength (UBS). The results was analyzed by one-way ANOVA. The tensile fracture surface were examined by scanning electron microscopy (SEM). Metallurgical analysis were also performed on polished longitudinal sectioned samples. For Co-Cr alloy, the UTS of casting wire group and commercially welding wire group was respectively (606.40+/-82.53)MPa and (693.61+/-47.68)MPa; the UBS was respectively (997.95+/-88.89)MPa and (1160.76+/-91.59)MPa. ANOVA showed a significant difference of UTS and UBS between the two groups at the 0.05 level (Pwelding wire group was respectively (558.14+/-46.75)MPa and (582.32+/-35.43)MPa; the UBS was respectively (1084.75+/-46.02)MPa and (1078.29+/-36.25)MPa. There was no significant difference between the two groups (P>0.05). SEM and metallurgical examination showed the welded zone exhibiting more cracks in the casting wire group than in the commercially welding wire group. It would be advisable to work with commercially welding wire for the joints that need better strength.

  4. Characterization and coating stability evaluation of nickel-titanium orthodontic esthetic wires: an in vivo study

    Directory of Open Access Journals (Sweden)

    Nina ARGALJI

    2017-08-01

    Full Text Available Abstract The objective of this study was to compare coating dimensions and surface characteristics of two different esthetic covered nickel-titanium orthodontic rectangular archwires, as-received from the manufacturer and after oral exposure. The study was designed for comparative purposes. Both archwires, as-received from the manufacturer, were observed using a stereomicroscope to measure coating thickness and inner metallic dimensions. The wires were also exposed to oral environment in 11 orthodontic active patients for 21 days. After removing the samples, stereomicroscopy images were captured, coating loss was measured and its percentage was calculated. Three segments of each wire (one as-received and two after oral exposure were observed using scanning electron microscopy for a qualitative analysis of the labial surface of the wires. The Lilliefors test and independent t-test were applied to verify normality of data and statistical differences between wires, respectively. The significance level adopted was 0.05. The results showed that the differences between the wires while comparing inner height and thickness were statistically significant (p < 0.0001. In average, the most recently launched wire presented a coating thickness twice that of the control wire, which was also a statistically significant difference. The coating loss percentage was also statistically different (p = 0.0346 when the latest launched wire (13.27% was compared to the control (29.63%. In conclusion, the coating of the most recent wire was thicker and more uniform, whereas the control had a thinner coating on the edges. After oral exposure, both tested wires presented coating loss, but the most recently launched wire exhibited better results.

  5. Joint Services Electronics Program.

    Science.gov (United States)

    1983-04-01

    is violated when the two halves of a biconical antenna are separated to permit connection to a two- wire line, the conical antenna is most...rhombic antenna , the conductors of which, in effect, lie along the edges of a volume like that occupied by a wire-mesh or metal-plate simulator. Since...Integral Equation," IEEE Trans. Antennas Procrgat. (submitted for publication). t ll II , : ] II -. .. - : I7 ,7 111.5 111.5 Resource Allocation With

  6. Numerical modelling of ozone production in a wire-cylinder corona discharge and comparison with a wire-plate corona discharge

    Science.gov (United States)

    Wang, Pengxiang; Chen, Junhong

    2009-02-01

    The effect of electrode configuration on ozone production in the direct-current corona discharge of dry and humid air is studied by a numerical model that combines the electron distribution in the corona plasma, plasma chemistry and transport phenomena. Two electrode configurations are considered: wire-cylinder discharge with air flowing along the wire axis and wire-plate discharge with air flowing transverse to the wire. The ozone distributions in both types of discharges are compared. For both electrode configurations, the ozone production rate is higher in the negative corona than in the positive corona and it decreases with an increase in relative humidity. More importantly, the detailed ozone distribution in the neighbourhood of the discharge wire, together with the ozone kinetics, reveals the possible difference in the ozone production from the two discharges. With the same operating conditions and sufficiently short flow residence time, the ozone production rate is nearly the same for both electrode configurations. When the flow residence time is longer than the characteristic time for homogeneous ozone destruction, the net ozone production is higher in the wire-cylinder discharge than in the wire-plate discharge due to relatively less ozone destruction.

  7. Application of the Wire Bonding Technology to a Flexible Neural Probe

    Science.gov (United States)

    Shimizu, Koichi; Nakanishi, Motofumi; Makikawa, Masaaki; Asajima, Syuzo; Konishi, Satoshi

    This paper proposes a novel neural probe using flexible metal wire for wire bonding on LSI chip. Wire bonding technology can provide a number of flexible wire arrays. The proposed neural probe is used for a nerve interface for functional electric stimulation (FES) technology which assists the paralysis of living body function by a spinal cord injury. The flexibility of probe will provide low invasive and safe neural interfaces for the nerve tissue from a long term view. We employ a combination of wire bonding and laser machining for the fabrication of aligned flexible probes. Aligned bonded flexible metal wires on electrodes are converted to probe arrays by cutting the bridge between electrodes. Typical dimension of a bonding wire is several tens μm in diameter and is suitable for neural probe to be inserted into nerve bundles. Needle shape is formed by electro-polishing of cut edge. Proposed method can be benefited by advantages of wire bonding as the widespread technology in electronics industry. Developed flexible neural probe based on the proposed technology is estimated as a nerve interface by inserting to a sciatic nerve of a rat.

  8. Molecular Electronics

    DEFF Research Database (Denmark)

    Jennum, Karsten Stein

    This thesis includes the synthesis and characterisation of organic compounds designed for molecular electronics. The synthesised organic molecules are mainly based on two motifs, the obigo(phenyleneethynylenes) (OPE)s and tetrathiafulvalene (TTF) as shown below. These two scaffolds (OPE and TTF...... transistors (Part 2). The synthetic protocols rely on stepwise Sonogashira coupling reactions. Conductivity studies on various OPE-based molecular wires reveal that mere OPE compounds have a higher electrical resistance compared to the cruciform based wires (up to 9 times higher). The most spectacular result...... be potential candidates for future molecular electronics Synthesis of a new donor-acceptor chromophore based on a benzoquinone- TTF motif (QuinoneDTF) is also described herein (Part 2). Reaction of this molecule with acid induces a colour change from purple to orange. The purple colour can be restored...

  9. Emittance growth due to Tevatron flying wires

    Energy Technology Data Exchange (ETDEWEB)

    Syphers, M; Eddy, Nathan

    2004-06-01

    During Tevatron injection, Flying Wires have been used to measure the transverse beam size after each transfer from the Main Injector in order to deduce the transverse emittances of the proton and antiproton beams. This amounts to 36 + 9 = 45 flies of each of 3 wire systems, with an individual wire passing through each beam bunch twice during a single ''fly''. below they estimate the emittance growth induced by the interaction of the wires with the particles during these measurements. Changes of emittance from Flying Wire measurements conducted during three recent stores are compared with the estimations.

  10. A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system

    Energy Technology Data Exchange (ETDEWEB)

    Michnoff R.; Biscardi, C.; Cerniglia, P.; Degen, C.; Gassner, D.; Hoff, L.; Hulsart, R.

    2012-04-15

    A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scanner assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.

  11. Plasma formation in metallic wire Z pinches

    Science.gov (United States)

    Chittenden; Lebedev; Ruiz-Camacho; Beg; Bland; Jennings; Bell; Haines; Pikuz; Shelkovenko; Hammer

    2000-04-01

    Plasma formation in metallic wire Z pinches is modeled using a two-dimensional resistive magnetohydrodynamics code. Modified Thomas-Fermi equations of state and dense plasma transport coefficients allow the phase transitions from solid to plasma to be approximated. Results indicate the persistence of a two-component structure with a cold, dense core embedded within a much hotter, low density, m=0 unstable corona. Extensive benchmark testing against data from a number of single-wire experiments is presented. Artificial laser schlieren and x-ray back-lighting images generated from the code data are compared directly to experimental results. The results were found to be insensitive to inaccuracies in the equations of state and transport coefficients. Simulations of individual wires in a wire array show different behavior to that observed experimentally due to the absence of three-dimensional effects. Simulations with similar conditions to wires in an array show a general trend in the plasma structure at start of implosion from discrete wires with large m=0 perturbation amplitudes to partially merged wires with smaller perturbation amplitudes as the number of wires is increased. Results for a wire number scan with aluminum wire arrays on the SATURN generator suggest that the observed sharp transition to high x-ray power at around 40 wires corresponds to a sharp decrease in m=0 perturbation amplitude and hence a sharp decrease in the seed perturbation for the Rayleigh-Taylor instability.

  12. Influence of the Working Gas Properties on the Anode Wire Modulation Effect of MWPC

    OpenAIRE

    Wang, Xiaohu

    2015-01-01

    For MWPC used for X-ray position detection, simulation study of the anode wire modulation effect of the detector was carried out with Garfield program. Different gas mixtures were used as the working gas in the simulation, so as to obtain the influence of the X-ray cross section and electron diffusion coefficient of the working gases on the anode wire modulation effect of MWPC which has a anode wire spacing of 2mm. Results show that, though working gas with higher X-ray cross section implies ...

  13. Kinetic ion simulations of wire loaded Z-pinches in the (r,theta) plane

    Energy Technology Data Exchange (ETDEWEB)

    Bateson, W.B.; Shon, J.W.; Hewett, D.W. [Lawrence Livermore National Lab., CA (United States)

    1998-12-31

    PBFA II-Z wire array implosions have achieved pulse compression with significant energy content in X-rays. In order to obtain better understanding of these experiments, the authors have extended GaPH beyond Fluid Element Particle In Cell (FE-PIC) ions to include fluid electrons, three temperature radiation transport, a fermi atomic module and magneto inductive effects. The 2D Cartesian code has allowed them to examine issues of interpenetration of the wire corona as it relates to inter-wire spacing.

  14. Effect of Experimental Parameters on Nanofiber Diameter from Electrospinning with Wire Electrodes

    Science.gov (United States)

    Zhu, Guocheng; Zhao, L. Y.; Zhu, L. T.; Deng, X. Y.; Chen, W. L.

    2017-09-01

    Polyvinylidene Fluoride (PVDF) nanofibers were electrospun by Nanospider equipment with wire electrodes. The parameters which would influence the fiber diameter were investigated in terms of solution concentration, cartridge speed (feed rate of solution), voltage, electrode distance, rotating wire speed, winding speed and slit diameter. The morphology and diameter of fibers were observed by scanning electron microscope. The results revealed that the solution concentration had significant influence on both fiber morphology and fiber diameter; the cartridge speed, voltage, electrode distance and slit diameter had slight effect on fiber diameter since the standard deviations were large; the rotating wire speed and the winding speed had insignificant influence on fiber diameter.

  15. InP/InAlAs/InGaAs-quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Kappelt, M.; Tuerck, V.; Grundmann, M.; Bimberg, D. [Technische Univ., Berlin (Germany); Cerva, H. [Siemens AG, Muenchen (Germany)

    1996-12-31

    Single InGaAs quantum wires and stacked InGaAs quantum wires with InAlAs barriers have been fabricated on v-grooved InP substrates by low pressure metal-organic chemical vapor deposition. The authors have found growth conditions where the InAlAs barrier exhibits a resharpening effect, similar to that of AlgaAs utilized for growth on GaAs substrates. The existence of structural and electronic quantum wires in the bottom of the grooves is proven.

  16. Use of Electronic Resources by M.Sc. Chemistry Students at Arts Science and Commerce College Chopda Dist-Jalgaon

    National Research Council Canada - National Science Library

    Dr.Paithankar Rajeev; R., Mr.Kamble V.R

    2017-01-01

    ... continuously growth in teaching learning process. In the modern era librarian should provide better services to the users for accessing e-resources as like e-books, e-journals, e-databases, e-reports etc...

  17. Barriers to electronic access and delivery of educational information in resource constrained public schools: a case of Greater Tubatse Municipality

    CSIR Research Space (South Africa)

    Pholotho, T

    2016-05-01

    Full Text Available Information and Communication Technologies (ICTs) are capable of expanding access to quality education, educational resources and provide teachers with new skills. Nevertheless, a majority of rural public schools have limited ICTs, mainly due...

  18. Electronic Grey Literature in Accelerator Science and Its Allied Subjects : Selected Web Resources for Scientists and Engineers

    CERN Document Server

    Rajendiran, P

    2006-01-01

    Grey literature Web resources in the field of accelerator science and its allied subjects are collected for the scientists and engineers of RRCAT (Raja Ramanna Centre for Advanced Technology). For definition purposes the different types of grey literature are described. The Web resources collected and compiled in this article (with an overview and link for each) specifically focus on technical reports, preprints or e-prints, which meet the main information needs of RRCAT users.

  19. Slice of LHC dipole wiring

    CERN Multimedia

    Dipole model slice made in 1994 by Ansaldo. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. 50’000 tonnes of steel sheets are used to make the magnet yokes that keep the wiring firmly in place. The yokes constitute approximately 80% of the accelerator's weight and, placed side by side, stretch over 20 km!

  20. Sintered wire cesium dispenser photocathode

    Science.gov (United States)

    Montgomery, Eric J; Ives, R. Lawrence; Falce, Louis R

    2014-03-04

    A photoelectric cathode has a work function lowering material such as cesium placed into an enclosure which couples a thermal energy from a heater to the work function lowering material. The enclosure directs the work function lowering material in vapor form through a low diffusion layer, through a free space layer, and through a uniform porosity layer, one side of which also forms a photoelectric cathode surface. The low diffusion layer may be formed from sintered powdered metal, such as tungsten, and the uniform porosity layer may be formed from wires which are sintered together to form pores between the wires which are continuous from the a back surface to a front surface which is also the photoelectric surface.

  1. EDITORIAL More than a wire More than a wire

    Science.gov (United States)

    Demming, Anna

    2010-10-01

    Nanowires are the natural evolution of the connections in circuits when scaled down to nanometre sizes. On closer inspection, of course, the role of nanowires in developing new technologies is much more than just a current-bearing medium. By sizing the diameters of these objects down to the nanoscale, their properties become increasingly sensitive to factors such as the gas composition, temperature and incident light of their surrounding environment, as well as defects and variations in diameter. What becomes important in modern electronics innovations is not just what is connected, but how. Nanowires had already begun to attract the attention of researchers in the early 1990s as advances in imaging and measurement devices invited researchers to investigate the properties of these one-dimensional structures [1, 2]. This interest has sparked ingenious ways of fabricating nanowires such as the use of a DNA template. A collaboration of researchers at Louisiana Tech University in the US hs provided an overview of various methods to assemble conductive nanowires on a DNA template, including a summary of different approaches to stretching and positioning the templates [3]. Work in this area demonstrates a neat parallel for the role of DNA molecules as the building blocks of life and the foundations of nanoscale device architectures. Scientists at HP Labs in California are using nanowires to shrink the size of logic arrays [4]. One aspect of electronic interconnects that requires particular attention at nanoscale sizes is the effect of defects. The researchers at HP Labs demonstrate that their approach, which they name FPNI (field-programmable nanowire interconnect), is extremely tolerant of the high defect rates likely to be found in these nanoscale structures, and allows reduction in size and power without significantly sacrificing the clock rate. Another issue in scaling down electronics is the trend for an increasing resistivity with decreasing wire width. Researchers

  2. Newnes electronics assembly pocket book

    CERN Document Server

    Brindley, Keith

    2013-01-01

    Produced in association with the Engineering Training Authority with contributions from dozens of people in the electronics industry. The material covers common skills in electrical and electronic engineering and concentrates mainly on wiring and assembly. 'Newnes Electronics Assembly Pocket Book' is for electronics technicians, students and apprentices.

  3. Genetic Optimization of Wire Antennas

    Directory of Open Access Journals (Sweden)

    Z. Raida

    1998-09-01

    Full Text Available The presented submission describes how genetic algorithms can be applied to the optimization and design of wire antennas. The proposed optimization method is easily programmable and well understandable on one hand, but relatively slowly converging and depending on the parameters of the genetic algorithms on the other hand. The disadvantages of the method are deeply discussed and their elimination is discussed in the paper.

  4. Positioning and joining of organic single-crystalline wires

    Science.gov (United States)

    Wu, Yuchen; Feng, Jiangang; Jiang, Xiangyu; Zhang, Zhen; Wang, Xuedong; Su, Bin; Jiang, Lei

    2015-01-01

    Organic single-crystal, one-dimensional materials can effectively carry charges and/or excitons due to their highly ordered molecule packing, minimized defects and eliminated grain boundaries. Controlling the alignment/position of organic single-crystal one-dimensional architectures would allow on-demand photon/electron transport, which is a prerequisite in waveguides and other optoelectronic applications. Here we report a guided physical vapour transport technique to control the growth, alignment and positioning of organic single-crystal wires with the guidance of pillar-structured substrates. Submicrometre-wide, hundreds of micrometres long, highly aligned, organic single-crystal wire arrays are generated. Furthermore, these organic single-crystal wires can be joined within controlled angles by varying the pillar geometries. Owing to the controllable growth of organic single-crystal one-dimensional architectures, we can present proof-of-principle demonstrations utilizing joined wires to allow optical waveguide through small radii of curvature (internal angles of ~90–120°). Our methodology may open a route to control the growth of organic single-crystal one-dimensional materials with potential applications in optoelectronics. PMID:25814032

  5. Revealing microstructural and mechanical characteristics of cold-drawn pearlitic steel wires undergoing simulated galvanization treatment

    Energy Technology Data Exchange (ETDEWEB)

    Fang Feng, E-mail: fangfeng@seu.edu.cn [School of Materials Science and Engineering, Southeast University, Nanjing 211189 (China); Hu Xianjun [School of Materials Science and Engineering, Southeast University, Nanjing 211189 (China); Jiangsu Sha-Steel Group, Zhangjiagang City, Jiangsu Province 215625 (China); Chen Shaohui [Jiangsu Sha-Steel Group, Zhangjiagang City, Jiangsu Province 215625 (China); Xie Zonghan [School of Engineering, Edith Cowen University, Joondalup, WA 6027 (Australia); Jiang Jianqing [School of Materials Science and Engineering, Southeast University, Nanjing 211189 (China)

    2012-06-15

    Highlights: Black-Right-Pointing-Pointer Annealing time on microstructure and mechanical properties of cold-drawn steel wires were studied. Black-Right-Pointing-Pointer Exothermic peak in cold-drawn wire was resulting from the spheroidization of lamellar cementite. Black-Right-Pointing-Pointer Spheroidization of lamellar cementite is the main effect for torsion property of wires after annealing. - Abstract: Spheroidization of lamellar cementite often occurs in cold-drawn pearlitic steel wires during galvanizing treatment, leading to the degradation of mechanical properties. Therefore, it is important to understand effects of galvanization process on microstructure and mechanical properties of cold-drawn wires. In this paper, cold-drawn steel wires were fabricated by cold drawing pearlitic steel rods from 13 mm to 6.9 mm in diameter. Thermal annealing at 450 Degree-Sign C was used to simulate galvanizing treatment of steel wires. Tensile strength, elongation and torsion laps of steel rods and wires with, and without, annealing treatment were determined. Microstructure was observed using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). In addition, differential scanning calorimetry (DSC) was used to probe the spheroidization temperature of cementite. Experimental results showed that tensile strength of wires increased from 1780 MPa to 1940 MPa for annealing <5 min, and then decreased. Tensile strength became constant for annealing >10 min. Elongation of wires decreased for annealing <2.5 min, and then recovered slightly. It approached a constant value for annealing >5 min. Tensile strength and elongation of wires were both influenced by the strain age hardening and static recovery processes. Notably, torsion laps of wires hardly changed when annealing time was less than 2.5 min, and then decreased rapidly. Its value became constant when the hold time is greater than 10 min. Lamellar cementite began to spheroidize at annealing >2.5 min

  6. Organometallic benzene-vanadium wire: A one-dimensional half-metallic ferromagnet

    DEFF Research Database (Denmark)

    Maslyuk, V.; Bagrets, A.; Meded, V.

    2006-01-01

    methods. We predict that the ground state of the wire is a 100% spin-polarized ferromagnet (half-metal). Its density of states is metallic at the Fermi energy for the minority electrons and shows a semiconductor gap for the majority electrons. We find that the half-metallic behavior is conserved up to 12......% longitudinal elongation of the wire. Ab initio electron transport calculations reveal that finite size vanadium-benzene clusters coupled to ferromagnetic Ni or Co electrodes will work as nearly perfect spin filters....

  7. Biocompatibility and durability of Teflon-coated platinum-iridium wires implanted in the vitreous cavity.

    Science.gov (United States)

    Nishida, Kentaro; Sakaguchi, Hirokazu; Xie, Ping; Terasawa, Yasuo; Ozawa, Motoki; Kamei, Motohiro; Nishida, Kohji

    2011-12-01

    Teflon-coated platinum-iridium wires are placed in the vitreous as electrodes in artificial vision systems. The purpose of this study was to determine whether these wires have toxicity in the vitreous cavity, and to examine the durability of their coating when grasped by forceps. Rabbits were implanted with platinum-iridium wires that were 50 μm in diameter and coated with Teflon to a total diameter of 68 or 100 μm. To examine the biocompatibility, electroretinograms (ERGs) and fluorescein angiography (FA) were performed before and 1 week, 1, 3, and 6 months after the implantation of the electrode. After 6 months, the eyes were histologically examined with light microscopy. To check the durability, the surface of a coated wire was examined with scanning electron microscopy after grasping with different types of forceps. At all times after the implantation the amplitudes and implicit times of the ERGs recorded were not significantly different from those recorded before the implantation (P > 0.05). FA showed no notable change during the follow-up periods. Histological studies showed that the retinas were intact after 6 months of implantation. There was no damage to the Teflon-coated wire after grasping the wire with forceps with silicon-coated tips, while surface damage of the Teflon that did not extend to the platinum-iridium wire was found when grasped by vitreoretinal forceps. We conclude that Teflon-coated platinum-iridium wire is highly biocompatible in the vitreous for at least 6 months. Wires should be handled with vitreoretinal forceps with silicone-coated tips in order to avoid causing damage during wire manipulation.

  8. EBSD analysis of tungsten-filament carburization during the hot-wire CVD of multi-walled carbon nanotubes

    CSIR Research Space (South Africa)

    Oliphant, CJ

    2014-02-01

    Full Text Available Filament condition during hot-wire chemical vapor deposition conditions of multi-walled carbon nanotubes is a major concern for a stable deposition process. We report on the novel application of electron backscatter diffraction to characterize...

  9. Laser wakefield acceleration using wire produced double density ramps

    Directory of Open Access Journals (Sweden)

    M. Burza

    2013-01-01

    Full Text Available A novel approach to implement and control electron injection into the accelerating phase of a laser wakefield accelerator is presented. It utilizes a wire, which is introduced into the flow of a supersonic gas jet creating shock waves and three regions of differing plasma electron density. If tailored appropriately, the laser plasma interaction takes place in three stages: Laser self-compression, electron injection, and acceleration in the second plasma wave period. Compared to self-injection by wave breaking of a nonlinear plasma wave in a constant density plasma, this scheme increases beam charge by up to 1 order of magnitude in the quasimonoenergetic regime. Electron acceleration in the second plasma wave period reduces electron beam divergence by ≈25%, and the localized injection at the density downramps results in spectra with less than a few percent relative spread.

  10. Laser Wakefield Acceleration Using Wire Produced Double Density Ramps

    CERN Document Server

    Burza, M; Svensson, K; Wojda, F; Persson, A; Hansson, M; Genoud, G; Marklund, M; Wahlström, C -G; Lundh, O

    2012-01-01

    A novel approach to implement and control electron injection into the accelerating phase of a laser wakefield accelerator (LWFA) is presented. It utilizes a wire, which is introduced into the flow of a supersonic gas jet creating shock waves and three regions of differing plasma electron density. If tailored appropriately, the laser plasma interaction takes place in three stages: Laser self-compression, electron injection and acceleration in the second plasma wave period. Compared to self-injection by wavebreaking of a nonlinear plasma wave in a constant density plasma, this scheme increases beam charge by up to one order of magnitude in the quasi-monoenergetic regime. Electron acceleration in the second plasma wave period reduces electron beam divergence by approximately 25 %, and the localized injection at the density downramps results in spectra with less than a few percent relative spread.

  11. "Cut wires grating – single longitudinal wire" planar metastructure to achieve microwave magnetic resonance in a single wire

    Directory of Open Access Journals (Sweden)

    G. Kraftmakher

    2012-09-01

    Full Text Available Here we present metastructures containing cut-wire grating and a single longitudinal cut-wire orthogonal to grating’s wires. Experimental investigations at microwaves show these structures can provide strong magnetic resonant response of a single nonmagnetic cut-wire in dependence on configuration and sizes in the case when metastructures are oriented along the direction of wave propagation and cut-wires of grating are parallel to the electric field of a plane electromagnetic wave. It is suggested a concept of magnetic response based on antiparallel resonant currents excited by magnetic field of surface polaritons in many spatial LC-circuits created from cut-wire pairs of a grating and section of longitudinal cut-wire. Three separately observed resonant effects connected with grating, LC-circuits and with longitudinal cut-wire have been identified applying measurements in waveguides, cutoff waveguides and free space. To tune and mark resonance split cut-wires are loaded with varactor diodes.

  12. Phosphorus in antique iron music wire.

    Science.gov (United States)

    Goodway, M

    1987-05-22

    Harpsichords and other wire-strung musical instruments were made with longer strings about the beginning of the 17th century. This change required stronger music wire. Although these changes coincided with the introduction of the first mass-produced steel (iron alloyed with carbon), carbon was not found in samples of antique iron harpsichord wire. The wire contained an amount of phosphorus sufficient to have impeded its conversion to steel, and may have been drawn from iron rejected for this purpose. The method used to select pig iron for wire drawing ensured the highest possible phosphorus content at a time when its presence in iron was unsuspected. Phosphorus as an alloying element has had the reputation for making steel brittle when worked cold. Nevertheless, in replicating the antique wire, it was found that lowcarbon iron that contained 0.16 percent phosphorus was easily drawn to appropriate gauges and strengths for restringing antique harpsichords.

  13. Electromagnetic Behaviour of Metallic Wire Structures

    CERN Document Server

    Chui, S T

    2013-01-01

    Despite the recent development and interest in the photonics of metallic wire structures, the relatively simple concepts and physics often remain obscured or poorly explained to those who do not specialize in the field. Electromagnetic Behaviour of Metallic Wire Structures provides a clear and coherent guide to understanding these phenomena without excessive numerical calculations.   Including both background material and detailed derivations of the various different formulae applied, Electromagnetic Behaviour of Metallic Wire Structures describes how to extend basic circuit theory relating to voltages, currents, and resistances of metallic wire networks to include situations where the currents are no longer spatially uniform along the wire. This lays a foundation for a deeper understanding of the many new phenomena observed in meta-electromagnetic materials.   Examples of applications are included to support this new approach making Electromagnetic Behaviour of Metallic Wire Structures a comprehensive and ...

  14. IEE wiring regulations explained and illustrated

    CERN Document Server

    Scaddan, Brian

    2013-01-01

    The IEE Wiring Regulations Explained and Illustrated, Second Edition discusses the recommendations of the IEE Regulations for the Electrical Equipment of Buildings for the safe selection or erection of wiring installations. The book emphasizes earthing, bonding, protection, and circuit design of electrical wirings. The text reviews the fundamental requirements for safety, earthing systems, the earth fault loop impedance, and supplementary bonding. The book also describes the different types of protection, such as protection against mechanical damage, overcurrent, under voltage (which prevents

  15. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  16. NEW DIRECTIONS IN THE ROLLED WIRE DEVELOPMENT

    Directory of Open Access Journals (Sweden)

    A. V. Vedeneev

    2004-01-01

    Full Text Available Analysis of the world practice and comparison with the competitors data shows, that for keeping up of RUP “BMZ'' competitiveness it is necessary to carry out works in directions of perfection of the steel wire cord production technology, development of steel wire cord, development of the breaker constructions with the high infiltration of rubber of wire with superstandard diameter and etc.

  17. Experimental setup to detect superconducting wire motion

    OpenAIRE

    K. Ruwali; A. Yamanaka; Y. Teramoto; K. Nakanishi; K. Hosoyama

    2009-01-01

    An experimental setup was designed and fabricated to study superconducting wire motion under the influence of electromagnetic force. Experiments were conducted at 4.2 K by varying the experimental conditions such as the tension to the superconducting wire and different insulating materials at the interface of the superconducting wire and head part. The insulating materials used in the experiments were polyimide film and a high strength polyethylene fiber cloth, Dyneema. Details of the experim...

  18. Influence of surface layer on mechanical and corrosion properties of nickel-titanium orthodontic wires.

    Science.gov (United States)

    Katić, Višnja; Curković, Helena Otmačić; Semenski, Damir; Baršić, Gorana; Marušić, Katarina; Spalj, Stjepan

    2014-11-01

    To analyze the effect of various coating formulations on the mechanical and corrosion properties of nickel-titanium (NiTi) orthodontic wires. Uncoated, rhodium-coated, and nitrified NiTi wires were observed with a three-point-bend test, surface roughness (Ra) measurement, scanning electron microscopy, energy dispersive spectroscopy, and electrochemical testing (open circuit potential, electrochemical impedance spectroscopy, and cyclic polarization scan). Differences in the properties of tested wire types were analyzed with analysis of variance and Tukey post hoc test. Uncoated and nitrified NiTi wires showed similar mechanical and anticorrosive properties, while rhodium-coated NiTi wires showed the highest Ra and significantly higher modulus of elasticity, yield strength, and delivery of forces during loading but not in unloading. Rhodium-coated NiTi wires also had the highest corrosion current density and corrosion potential, lowest impedance modulus, and two time constants on Bode plot, one related to the Rh/Au coating and the other to underlying NiTi. Working properties of NiTi wires were unaffected by various coatings in unloading. Nitrification improved corrosion resistance. Rhodium coating reduced corrosion resistance and pronounced susceptibility to pitting corrosion in artificial saliva because of galvanic coupling between the noble coating and the base alloy.

  19. The Installation for Fatigue and Destruction Tests of Thin Wires

    Directory of Open Access Journals (Sweden)

    D. V. Prosvirin

    2015-01-01

    Full Text Available The fatigue strength of high-strength materials such as wire is, essentially, dependent on the surface state, stress concentrators, non-metal inclusions, etc. Multifactorial process of damage accumulation and fracture under cyclic loading makes it difficult to predict the durability of structural materials. So fatigue tests, taking into account the operating conditions of stress exposure as much as possible, are of special importance.A feature of the wire fatigue tests is that it is complicated to secure the samples and create the alternate stresses. Currently, there is no equipment to study the fatigue strength of the wire in accordance with GOST 1579-93. Partly the problem of the wire fatigue tests was solved owing to using the installation developed in IMET RAS and considered as the base case. However, the installation has significant disadvantages, namely: a complicated for implementing in practice method to control stresses in the sample; an imperfect system to count cycles; an incapability to change the engine speed of the motor and thus, the frequency of loading.In developing the new design all the basic blocks of installation were upgraded such as drive unit; unit to control stress in the sample; unit for determining the number of cycles to failure.To change the stresses in the sample the paper offers to use the platform from polymethylmethacrylate with slotted curved channels of different radii. The stresses in the sample are dependent on the channel radius R, the wire diameter d and the modulus of elasticity E of the material and may vary in the range of 200 - 1200 MPa. The use of CNC machines in cutting the channels allows stress adjustment within ± 0,1 MPa.The developed design is used to drive the rotation of the wire and makes it possible to change the frequency of loading in the range of 0 - 100 Hz. It is shown that the use of the closing relay in drive design and the transition to an electronic system of determining the number of

  20. Clinician‐selected Electronic Information Resources do not Guarantee Accuracy in Answering Primary Care Physicians’ Information Needs. A review of: McKibbon, K. Ann, and Douglas B. Fridsma. “Effectiveness of Clinician‐selected Electronic Information Resources for Answering Primary Care Physicians’ Information Needs.” Journal of the American Medical Informatics Association 13.6 (2006: 653‐9.

    Directory of Open Access Journals (Sweden)

    Martha Ingrid Preddie

    2008-03-01

    Full Text Available Objective – To determine if electronic information resources selected by primary care physicians improve their ability to answer simulated clinical questions.Design – An observational study utilizing hour‐long interviews and think‐aloud protocols.Setting – The offices and clinics of primary care physicians in Canada and the United States.Subjects – Twenty‐five primary care physicians of whom 4 were women, 17 were from Canada, 22 were family physicians,and 24 were board certified.Methods – Participants provided responses to 23 multiple‐choice questions. Each physician then chose two questions and looked for the answers utilizing information resources of their own choice. The search processes, chosen resources and search times were noted. These were analyzed along with data on the accuracy of the answers and certainties related to the answer to each clinical question prior to the search.Main results – Twenty‐three physicians sought answers to 46 simulated clinical questions. Utilizing only electronic information resources, physicians spent a mean of 13.0 (SD 5.5 minutes searching for answers to the questions, an average of 7.3(SD 4.0 minutes for the first question and 5.8 (SD 2.2 minutes to answer the second question. On average, 1.8 resources were utilized per question. Resources that summarized information, such as the Cochrane Database of Systematic Reviews, UpToDate and Clinical Evidence, were favored 39.2% of the time, MEDLINE (Ovid and PubMed 35.7%, and Internet resources including Google 22.6%. Almost 50% of the search and retrieval strategies were keyword‐based, while MeSH, subheadings and limiting were used less frequently. On average, before searching physicians answered 10 of 23 (43.5% questions accurately. For questions that were searched using clinician‐selected electronic resources, 18 (39.1% of the 46 answers were accurate before searching, while 19 (42.1% were accurate after searching. The difference of

  1. Analyzing the Academic Research Trends by Using University Digital Resources: A Bibliometric Study of Electronic Commerce in China

    Science.gov (United States)

    Fatima, Anam; Abbas, Asad; Ming, Wan; Zaheer, Ahmad Nawaz; Akhtar, Masood-ul-Hassan

    2017-01-01

    Technology plays a vital role in every field of life especially in business and education. Electronic commerce (EC) begins in the year of 1991 right after internet was introduced for commercial use. It is known to be the 12th five years' plan (2011 to 2015) of Chinese Ministry of Industry and Information Technology. The main "objective"…

  2. Minimisation of the wire position uncertainties of the new CERN vacuum wire scanner

    CERN Document Server

    AUTHOR|(CDS)2069346; Barjau Condomines, A

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new fast wire scanner is foreseen to measure small emittance beams throughout the LHC injector chain, which demands a wire travelling speed up to 20 ms-1 and position measurement accuracy of the order of a few microns. The vibrations of the mechanical parts of the system, and particularly the vibrations of the thin carbon wire, were identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations is a high priority for the design and operation of the new device. This document presents the work performed to understand the main causes of the wire vibrations observed in one of the existing wire scanner and the new proposed design.

  3. Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose:The Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL) provides a variety of research, design engineering and prototype fabrication services...

  4. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  5. Maximizing Resource Utilization in Video Streaming Systems

    Science.gov (United States)

    Alsmirat, Mohammad Abdullah

    2013-01-01

    Video streaming has recently grown dramatically in popularity over the Internet, Cable TV, and wire-less networks. Because of the resource demanding nature of video streaming applications, maximizing resource utilization in any video streaming system is a key factor to increase the scalability and decrease the cost of the system. Resources to…

  6. Long-range beam–beam compensation using wires

    CERN Document Server

    Zimmermann, F

    2015-01-01

    At the LHC, the effect of unavoidable long-range beam–beam collisions reduces the dynamic aperture, calling for a minimum crossing angle. A wire compensator partially cancels the effect of the long-range collisions, and may allow operation with reduced crossing angle or decreased beta function at the interaction point, thereby increasing the (virtual) peak luminosity. In this chapter, we describe the proposed compensation scheme, previous validation experiments with a single beam and multiple wires at the SPS, simulations for the LHC high-luminosity upgrade, a demonstrator project with real long-range encounters foreseen in the LHC proper, and the possible use of a low-energy electron beam as a future ultimate “wire”.

  7. Charge Transport through Organic Molecular Wires Embedded in Ultrathin Insulating Inorganic Layer

    Energy Technology Data Exchange (ETDEWEB)

    Edri, E; Frei, H

    2015-12-07

    Dense phase silica layers with thickness of a few nanometers featuring embedded organic molecular wires of type p-oligo(phenylenevinylene) are shown by visible light sensitized electrochemical measurements to transport charges across the insulating membrane. Here, we find that such hybrid materials combination allows electronic charge transport only through the wires, while blocking molecular transport. Embodiment of the wire molecules in the silica was accomplished by atomic layer deposition under mild temperature conditions. Grown on Co oxide films for water oxidation, with the wire molecules covalently anchored on the oxide surface, the layer functions as a proton conducting separation membrane. Characterization by XPS, FT-IR and STEM/EDX confirms the integrity of the silica-encapsulated organic wires. Cyclic voltammetry with redox couple of selected potential relative to the energy levels of the wire molecules shows that the membrane is free of pinholes. The new type of membrane allows separation of incompatible redox reaction environments on the length scale of nanometers while enabling controlled electron transport between them. Finally, this opens up the coupling of carbon dioxide reduction with water oxidation, the essential reactions of artificial photosynthesis, in an integrated nanoscale photosystem.

  8. THERMO-MECHANICALLY PROCESSED ROLLED WIRE FOR HIGH-STRENGTH ON-BOARD WIRE

    Directory of Open Access Journals (Sweden)

    V. A. Lutsenko

    2011-01-01

    Full Text Available It is shown that at twisting of wire of diameter 1,83 mm, produced by direct wire drawing of thermomechanically processed rolled wire of diameter 5,5 mm of steel 90, metal stratification is completely eliminated at decrease of carbon, manganese and an additional alloying of chrome.

  9. Finite element analysis on the wire breaking rule of 1×7IWS steel wire rope

    Directory of Open Access Journals (Sweden)

    Wenzheng Du

    2017-01-01

    Full Text Available Taking the wire rope of 1×7+IWS structure as the research object, the influences of the number of broken wires on the stress distribution under the same axial load were simulated and analysed, and it also explored the rule of wire breaking of steel wire ropes. Based on the SolidWorks software, the three-dimensional model of the wire rope was established. Importing the model into the ABAQUS, the finite element model of the steel wire rope was established. Firstly 5000 N axial tension was placed on the rope, the stress distribution was simulated and analysed, and the steel wire with the largest stress distribution was found out. Then one steel wire was truncated with the load unchanged, and the finite element simulation was carried out again, and repeated the steps several times. The results show that, with the increase of the number of broken wires, the Von-Mises stress of the wire rope increases sharply, and the stress distribution is concentrated on the rest of the unbroken wires, which brings great challenges to the safety of the wire rope.

  10. Secondary particle acquisition system for the CERN beam wire scanners upgrade

    CERN Document Server

    Sirvent, J L; Emery, J; Diéguez, A

    2015-01-01

    The increasing requirements of CERN experiments make essential the upgrade of beam instrumentation in general, and high accuracy beam profile monitors in particular. The CERN Beam Instrumentation Group has been working during the last years on the Wire Scanners upgrade. These systems cross a thin wire through a circulating beam, the resulting secondary particles produced from beam/wire interaction are detected to reconstruct the beam profile. For the new secondary shower acquisition system, it is necessary to perform very low noise measurements with high dynamic range coverage. The aim is to design a system without tuneable parameters and compatible for any beam wire scanner location at the CERN complex. Polycrystalline chemical vapour deposition diamond detectors (pCVD) are proposed as new detectors for this application because of their radiation hardness, fast response and linearity over a high dynamic range. For the detector readout, the acquisition electronics must be designed to exploit the detector capa...

  11. Share and share alike: encouraging the reuse of academic resources through the Scottish electronic Staff Development Library

    Directory of Open Access Journals (Sweden)

    Lorna M. Campbell

    2001-12-01

    Full Text Available The Scottish electronic Staff Development Library (http://www.sesdl.scotcit.acuk is an ongoing collaborative project involving the Universities of Edinburgh, Paisley and Strathclyde which has been funded by SHEFC as part of their current ScotCIT Programme (http:llwww.scotcit.ac.uk. This project is being developed in response to the increasing demand for flexible, high-quality staff development materials.

  12. Electronic plants.

    Science.gov (United States)

    Stavrinidou, Eleni; Gabrielsson, Roger; Gomez, Eliot; Crispin, Xavier; Nilsson, Ove; Simon, Daniel T; Berggren, Magnus

    2015-11-01

    The roots, stems, leaves, and vascular circuitry of higher plants are responsible for conveying the chemical signals that regulate growth and functions. From a certain perspective, these features are analogous to the contacts, interconnections, devices, and wires of discrete and integrated electronic circuits. Although many attempts have been made to augment plant function with electroactive materials, plants' "circuitry" has never been directly merged with electronics. We report analog and digital organic electronic circuits and devices manufactured in living plants. The four key components of a circuit have been achieved using the xylem, leaves, veins, and signals of the plant as the template and integral part of the circuit elements and functions. With integrated and distributed electronics in plants, one can envisage a range of applications including precision recording and regulation of physiology, energy harvesting from photosynthesis, and alternatives to genetic modification for plant optimization.

  13. The Eulerian buckling test for orthodontic wires.

    Science.gov (United States)

    De Santis, R; Dolci, F; Laino, A; Martina, R; Ambrosio, L; Nicolais, L

    2008-04-01

    Orthodontic treatment is mainly dependent on the loads developed by metal wires. The load developed by a buckled orthodontic wire is of great concern for molar distalization and cannot be simply derived from mechanical properties measured through classical tests (i.e. tensile, torsion, and bending). A novel testing method, based on the Eulerian approach of a simple supported beam, has been developed in order to measure the load due to buckling of orthodontic wires. Elastic titanium molybdenum alloy (TMA; SDS Ormco) and superelastic Nitinol (3M Unitek) and copper nickel-titanium (NiTi; SDS Ormco) wires, each having a rectangular cross section of 0.016 x 0.022 square inches (0.41 x 0.56 mm(2)), were used. The wires were activated and deactivated by loading and unloading. In order to analyse thermo-mechanical properties in buckling, mechanical tests were assisted by calorimetric measurements through differential scanning calorimetry (DSC). Statistical analysis to determine differences between the samples was undertaken using two-way analysis of variance (ANOVA) and Tukey's post hoc test, and one-way ANOVA to assess differences between the tested wires under similar conditions and different materials. The results suggest that the load due to buckling depends on material composition, wire length, the amount of activation, temperature, and deformation rate. The results can be considered as the lower bound for the loads experienced by teeth as far as a buckled wire is concerned. At a temperature higher than the austenite finish transition temperature, superelastic wires were strongly dependent on temperature and deformation rate. The effect due to an increase of deformation rate was similar to that of a decrease of temperature. Load variations due to temperature of a superelastic wire with a length of 20 mm were estimated to be approximately 4 g/degrees C. The high performance of an applied superelastic wire may be related to the high dynamics of the load in relation to

  14. FUNCTIONS OF ELECTRONIC LEARNING RESOURCES IN THE PROCESS OF PROFESSION-ORIENTED ORAL SPEECH TRAINING OF FUTURE TEACHERS OF FRENCH LANGUAGE

    Directory of Open Access Journals (Sweden)

    E. Yakovenko-Glushenkova

    2014-07-01

    Full Text Available The article analyzes the use of information and communication technologies in the formation of profession-oriented competence in listening and speaking (monologic, dialogic speech of future teachers of French language in the initial school (I and II years. In order to assure the effective use of ICT in the formation of profession-oriented oral speech competence of future teachers of French language in terms of analyzing, systematizing and summarizing of scientific references the following criterion of the selection of electronic resources as the educational material were identified by the author: relevance (modernity; originality; thoroughness; topicality; informative value; applicability; availability; suitability to communicative needs of future teachers of French language, to their intelligence level and interests; professionally informative significancy; interactivity; contextuality; media intension; social and cultural value; educational value. In turn, the functional use of ICT in formation of profession-oriented oral speech competence of future teachers of French language is represented by the classification, according to which all electronic resources according to their functions are divided into communicative, share, documentation, generative and interactive that is demonstrated by the corresponding examples.

  15. Microstructures of beta-titanium orthodontic wires joined by infrared brazing.

    Science.gov (United States)

    Iijima, Masahiro; Brantley, William A; Kawashima, Isao; Baba, Naoki; Alapati, Satish B; Yuasa, Toshihiro; Ohno, Hiroki; Mizoguchi, Itaru

    2006-10-01

    The microstructures and interdiffusion in brazed beta-titanium orthodontic wires were investigated by scanning electron microscopy and electron probe microanalysis, respectively. Beta-titanium wire (Ti-11Mo-6Zr-4Sn) with cross-section dimensions of 0.032 in. x 0.032 in., titanium-based braze alloy (Ti-30Ni-20Cu), and silver-based braze alloy (Ag-22Cu-17Zn-5Sn) were selected for the study. Brazing was performed using infrared radiation (RS-1) under an argon atmosphere. Specimens were etched with two solutions (2.5% HF + 2.5% HNO(3) + 95% H(2)O; 25% HN(4)OH + 30% H(2)O(2) + 45%H(2)O). It was found that the silver-based braze alloy has a eutectic structure. In the diffusion layer between the beta-titanium wire and this silver-based braze alloy, Cu and Ti were enriched on the wire side, and Sn and Ti were enriched on the braze alloy side. The titanium-based braze alloy has a dendritic structure. Beta-titanium wire specimens brazed with the titanium-based braze alloy had a thicker intermediate area compared to the silver alloy; Ti in the diffusion layer had an irregular concentration gradient, and the braze alloy side had higher Ti concentration. The original microstructure of the beta-titanium wire was not altered with the use of either braze alloy. Infrared brazing of beta-titanium orthodontic wire is acceptable for clinical use, since the wire microstructure did not deteriorate with either the titanium-based or silver-based braze alloy. The differing microstructures of the joint regions for the two braze alloys suggest that the joint strengths may also differ.

  16. Wire grid and wire scanner design for the CERN Linac4

    CERN Document Server

    Roncarolo, F; Cheymol, B; Dutriat, C; Duraffourg, M; Focker, G J; Raich, U; Vuitton, C

    2010-01-01

    As part of the CERN LHC injector chain upgrade, LINAC4 [1] will accelerate H- ions from 45 KeV to 160 MeV. A number of wire grids and wire scanners will be used to characterize the beam transverse profile. This paper covers all monitor design aspects intended to cope with the required specifications. In particular, the overall measurement robustness, accuracy and sensitivity must be satisfied for different commissioning and operational scenarios. The physics mechanisms generating the wire signals and the wire resistance to beam induced thermal loads have been considered in order to determine the most appropriate monitor design in terms of wire material and dimensions.

  17. Steer-by-wire innovations and demonstrator

    NARCIS (Netherlands)

    Lupker, H.A.; Zuurbier, J.; Verschuren, R.M.A.F.; Jansen, S.T.H.; Willemsen, D.M.C.

    2002-01-01

    Arguments for 'by-wire' systems include production costs, packaging and traffic safety. Innovations concern both product and development process e.g. combined virtual engineering and Hardware-in-the-loop testing. Three Steer-by-wire systems are discussed: a steering system simulator used as a

  18. Add-On Shielding for Unshielded Wire

    Science.gov (United States)

    Koenig, J. C.; Billitti, J. W.; Tallon, J. M.

    1983-01-01

    Fabrication sequence used to produce compact shields slipped into place from free ends of wires already soldered into connectors at other ends. Single shields are formed into harnesses by connecting grounding jumpers. Technique is especially useful for small diameter wire attached to microminiature connectors.

  19. WIRED magazine announces rave awards nominees

    CERN Multimedia

    2002-01-01

    WIRED Magazine has anounced the nominees for its fourth annual WIRED Rave Awards, celebrating innovation and the individuals transforming commerce and culture. Jeffrey Hangst of the University of Aarhus has been nominated in the science category, for his work on the ATHENA Experiment, CERN (1/2 page).

  20. Kirschner Wire Breakage during Removal Requiring Retrieval

    Directory of Open Access Journals (Sweden)

    Kai Yuen Wong

    2016-01-01

    Full Text Available Kirschner wires (K-wires are widely used for fixation of fractures and dislocations in the hand as they are readily available, reliable, and cost-effective. Complication rates of up to 18% have been reported. However, K-wire breakage during removal is rare. We present one such case illustrating a simple technique for retrieval. A 35-year-old male presented with a distal phalanx fracture of his right middle finger. This open fracture was treated with K-wire fixation. Postoperatively, he developed a pin site infection with associated finger swelling. The K-wire broke during removal with the proximal piece completely retained in his middle phalanx. To minimise risk of osteomyelitis, the K-wire was removed with a novel surgical technique. He had full return of hand function. Intraoperative K-wire breakage has a reported rate of 0.1%. In our case, there was no obvious cause of breakage and the patient denied postoperative trauma. On the other hand, pin site infections are much more common with reported rates of up to 7% in the hand or wrist. K-wire fixation is a simple method for bony stabilisation but can be a demanding procedure with complications often overlooked. It is important to be aware of the potential sequelae.

  1. Emulating Wired Backhaul with Wireless Network Coding

    DEFF Research Database (Denmark)

    Thomsen, Henning; De Carvalho, Elisabeth; Popovski, Petar

    2014-01-01

    , the uplink traffic to the user, remains identical to the one performed in a wired system. In the broadcast phase, the decoding of the downlink traffic can also be guaranteed to remain identical. Hence, our solution claims an emulation of a wired backhaul with wireless network coding with same performance. We...

  2. Wire compensation: Performance, SPS MDs, pulsed system

    CERN Document Server

    Dorda, U

    2008-01-01

    A wire compensation (BBLR) scheme has been proposed in order to improve the long range beam-beam performance of the nominal LHC and its phase 1 and phase 2 upgrades[1]. In this paper we present experimental experience of the CERN SPS wires (BBLR) and report on progress with the RF BBLR.

  3. 75 FR 4584 - Wire Decking From China

    Science.gov (United States)

    2010-01-28

    ... and whether shipped as a kit or packaged separately. Wire decking is produced from carbon or alloy..., zinc or nickel coated), coated (e.g., with paint, epoxy, or plastic), or uncoated (``raw''). The wire... before June 28, 2010, but such final comments must not contain new factual information and must otherwise...

  4. Wire scanners in low energy accelerators

    CERN Document Server

    Elmfors, P; Huhtinen, M; Lindroos, M; Olsfors, J; Raich, U

    1997-01-01

    Fast wire scanners are today considered as part of standard instrumentation in high energy synchrotrons. The extension of their use to synchrotrons working at lower energies, where Coulomb scattering can be important and the transverse beam size is large, introduces new complications considering beam heating of the wire, composition of the secondary particle shower and geometrical consideration in the detection set-up. A major problem in treating these effects is that the creation of secondaries in a thin carbon wire by a energetic primary beam is difficult to describe in an analytical way. We are here presenting new results from a full Monte Carlo simulation of this process yielding information on heat deposited in the wire, particle type and energy spectrum of secondaries and angular dependence as a function of primary beam energy. The results are used to derive limits for the use of wire scanners in low energy accelerators.

  5. Electronics for dummies

    CERN Document Server

    Shamieh

    2015-01-01

    Explore the basic concepts of electronics, build your electronics workbench, and begin creating fun electronics projects right away! Electronics For Dummies, 3rd Edition is your guide to the world of electronics. Spanning circuitry, wiring, robotics, transmitters, amplifiers, and more, this book demystifies electricity basics and beyond. The third edition offers new content revised to reflect the latest advancements in the electronics field, and it offers full color project examples to spark your creativity and inspire you to put your new skills to use! Packed with projects that can be comple

  6. Use of CCSDS Packets Over SpaceWire to Control Hardware

    Science.gov (United States)

    Haddad, Omar; Blau, Michael; Haghani, Noosha; Yuknis, William; Albaijes, Dennis

    2012-01-01

    For the Lunar Reconnaissance Orbiter, the Command and Data Handling subsystem consisted of several electronic hardware assemblies that were connected with SpaceWire serial links. Electronic hardware would be commanded/controlled and telemetry data was obtained using the SpaceWire links. Prior art focused on parallel data buses and other types of serial buses, which were not compatible with the SpaceWire and the core flight executive (CFE) software bus. This innovation applies to anything that utilizes both SpaceWire networks and the CFE software. The CCSDS (Consultative Committee for Space Data Systems) packet contains predetermined values in its payload fields that electronic hardware attached at the terminus of the SpaceWire node would decode, interpret, and execute. The hardware s interpretation of the packet data would enable the hardware to change its state/configuration (command) or generate status (telemetry). The primary purpose is to provide an interface that is compatible with the hardware and the CFE software bus. By specifying the format of the CCSDS packet, it is possible to specify how the resulting hardware is to be built (in terms of digital logic) that results in a hardware design that can be controlled by the CFE software bus in the final application

  7. Nonequilibrium functional bosonization of quantum wire networks

    Energy Technology Data Exchange (ETDEWEB)

    Ngo Dinh, Stephane, E-mail: stephane.ngodinh@kit.edu [Institut fuer Theorie der Kondensierten Materie, Karlsruhe Institute of Technology, 76128 Karlsruhe (Germany); DFG Center for Functional Nanostructures, Karlsruhe Institute of Technology, 76128 Karlsruhe (Germany); Bagrets, Dmitry A. [Institut fuer Theoretische Physik, Universitaet zu Koeln, Zuelpicher Str. 77, 50937 Koeln (Germany); Mirlin, Alexander D. [Institut fuer Theorie der Kondensierten Materie, Karlsruhe Institute of Technology, 76128 Karlsruhe (Germany); Institut fuer Nanotechnologie, Karlsruhe Institute of Technology, 76021 Karlsruhe (Germany); DFG Center for Functional Nanostructures, Karlsruhe Institute of Technology, 76128 Karlsruhe (Germany); Petersburg Nuclear Physics Institute, 188300 St. Petersburg (Russian Federation)

    2012-11-15

    We develop a general approach to nonequilibrium nanostructures formed by one-dimensional channels coupled by tunnel junctions and/or by impurity scattering. The formalism is based on nonequilibrium version of functional bosonization. A central role in this approach is played by the Keldysh action that has a form reminiscent of the theory of full counting statistics. To proceed with evaluation of physical observables, we assume the weak-tunneling regime and develop a real-time instanton method. A detailed exposition of the formalism is supplemented by two important applications: (i) tunneling into a biased Luttinger liquid with an impurity, and (ii) quantum Hall Fabry-Perot interferometry. - Highlights: Black-Right-Pointing-Pointer A nonequilibrium functional bosonization framework for quantum wire networks is developed Black-Right-Pointing-Pointer For the study of observables in the weak tunneling regime a real-time instanton method is elaborated. Black-Right-Pointing-Pointer We consider tunneling into a biased Luttinger liquid with an impurity. Black-Right-Pointing-Pointer We analyze electronic Fabry-Perot interferometers in the integer quantum Hall regime.

  8. Laser Wire and Beam Position Monitor tests

    CERN Document Server

    Boogert, S T; Lyapin, A; Nevay, L; Snuverink, J

    2013-01-01

    This subtask involved two main activities; Firstly the development and subsequent usage of high resolution beam position monitors (BPM) for the International Linear Collider (ILC) and Compact Linear Collider projects (CLIC); and secondly the development of a laser-wire (LW) transverse beam size measurement systems. This report describes the technical progress achieved at a large-scale test ILC compatible BPM system installed at the Accelerator Test Facility 2 (ATF2). The ATF2 is an energy-scaled demonstration system for the final focus systems required to deliver the particle beams to collision at the ILC and CLIC. The ATF2 cavity beam position monitor system is one of the largest of its kind and rivals systems used at free electron lasers. The ATF2 cavity beam position system has achieved a position resolutionof 250 nm (with signal attuenation) and 27 nm (without attenuation). The BPM system has been used routinely for lattice diagnostics, beam based alignment and wakefield measurements. Extensive experience...

  9. Surface characterization of nickel titanium orthodontic arch wires

    Science.gov (United States)

    Krishnan, Manu; Seema, Saraswathy; Tiwari, Brijesh; Sharma, Himanshu S.; Londhe, Sanjay; Arora, Vimal

    2015-01-01

    Background Surface roughness of nickel titanium orthodontic arch wires poses several clinical challenges. Surface modification with aesthetic/metallic/non metallic materials is therefore a recent innovation, with clinical efficacy yet to be comprehensively evaluated. Methods One conventional and five types of surface modified nickel titanium arch wires were surface characterized with scanning electron microscopy, energy dispersive analysis, Raman spectroscopy, Atomic force microscopy and 3D profilometry. Root mean square roughness values were analyzed by one way analysis of variance and post hoc Duncan's multiple range tests. Results Study groups demonstrated considerable reduction in roughness values from conventional in a material specific pattern: Group I; conventional (578.56 nm) > Group V; Teflon (365.33 nm) > Group III; nitride (301.51 nm) > Group VI (i); rhodium (290.64 nm) > Group VI (ii); silver (252.22 nm) > Group IV; titanium (229.51 nm) > Group II; resin (158.60 nm). It also showed the defects with aesthetic (resin/Teflon) and nitride surfaces and smooth topography achieved with metals; titanium/silver/rhodium. Conclusions Resin, Teflon, titanium, silver, rhodium and nitrides were effective in decreasing surface roughness of nickel titanium arch wires albeit; certain flaws. Findings have clinical implications, considering their potential in lessening biofilm adhesion, reducing friction, improving corrosion resistance and preventing nickel leach and allergic reactions. PMID:26843749

  10. A torquing shearing interferometer for cylindrical wire array experiments.

    Science.gov (United States)

    Pikuz, S A; Schrafel, P C; Shelkovenko, T A; Kusse, B R

    2008-10-01

    In standard shearing interferometry, a single probing beam passes through a perturbing medium and is then split into two beams. A linear shift results in an overlap, an interference, and a fringe pattern yielding the perturbing medium density profile. The probing beam usually needs to be larger than the perturbing medium so that part of it passes through a well separated low density region. During early time axial (end-on) views of imploding cylindrical wire arrays low density regions lie in between the high density regions that are near the initial wire positions. In addition, for end-on viewing, the probing beam diameter is limited by electrodes and is comparable to the array diameter. In this case a linear translation will not work but the overlap can be accomplished by an azimuthal rotation of one beam with respect to the other. Such a torquing shearing interferometer has been set up on the COBRA experiment to give time resolved, radial, and azimuthal electron density profiles during early time cylindrical wire array implosions.

  11. Dielectron analysis in p-p collisions at 3.5 GeV with the HADES spectrometer. {omega}-meson line shape and a new electronics readout for the multi-wire drift chambers

    Energy Technology Data Exchange (ETDEWEB)

    Tarantola Peloni, Attilio

    2011-06-15

    The HADES (High Acceptance DiElectron Spectrometer) is an experimental apparatus installed at the heavy-ion synchrotron SIS-18 at GSI, Darmstadt. The main physics motivation of the HADES experiment is the measurement of e{sup +}e{sup -} pairs in the invariant-mass range up to 1 GeV/c{sup 2} in heavy-ion collisions as well as in pion and proton-induced reactions. The HADES physics program is focused on in-medium properties of the light vector mesons {rho}(770), {omega}(783) and {phi}(1020), which decay with a small branching ratio into dileptons. Dileptons are penetrating probes which allow to study the in-medium properties of hadrons. However, in heavy-ion collisions, the measurement of such lepton pairs is difficult because they are rare and have a very large combinatorial background. Recently, HADES has been upgraded with new detectors and new electronics in order to handle higher intensity beams and reactions with heavy nuclei up to Au. HADES will continue for a few more years its rich physics program at its current place at SIS-18 and then move to the upcoming international Facility for Antiproton and Ion Research (FAIR) accelerator complex. In this context the physics results presented in this work are important prerequisites for the investigation of in-medium vector meson properties in p + A and A+A collisions. This work consists of five chapters. The first chapter introduces the physics motivation and a review of recent physics results. In the second chapter, the HADES spectrometer is described and its sub-detectors are presented. Chapter three deals with the issue of lepton identification and the reconstruction of the dielectron spectra in p + p collisions is presented. Here, two reactions are characterized: inclusive and exclusive dilepton production reactions. From the spectra obtained, the corresponding cross sections are presented with the respective statistical and systematical errors. A comparison with theoretical models is included as well

  12. Triazatriangulene as binding group for molecular electronics

    DEFF Research Database (Denmark)

    Wei, Zhongming; Wang, Xintai; Borges, Anders

    2014-01-01

    The triazatriangulene (TATA) ring system was investigated as a binding group for tunnel junctions of molecular wires on gold surfaces. Self-assembled monolayers (SAMs) of TATA platforms with three different lengths of phenylene wires were fabricated, and their electrical conductance was recorded ...... with its high stability and directionality make this binding group very attractive for molecular electronic measurements and devices. (Figure Presented)....

  13. Wire pad chamber for LHCb muon system

    CERN Document Server

    Botchine, B; Lazarev, V A; Sagidova, N; Vorobev, A P; Vorobyov, A; Vorobyov, Alexei

    2000-01-01

    2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.

  14. LabVIEW Interface for PCI-SpaceWire Interface Card

    Science.gov (United States)

    Lux, James; Loya, Frank; Bachmann, Alex

    2005-01-01

    This software provides a LabView interface to the NT drivers for the PCISpaceWire card, which is a peripheral component interface (PCI) bus interface that conforms to the IEEE-1355/ SpaceWire standard. As SpaceWire grows in popularity, the ability to use SpaceWire links within LabVIEW will be important to electronic ground support equipment vendors. In addition, there is a need for a high-level LabVIEW interface to the low-level device- driver software supplied with the card. The LabVIEW virtual instrument (VI) provides graphical interfaces to support all (1) SpaceWire link functions, including message handling and routing; (2) monitoring as a passive tap using specialized hardware; and (3) low-level access to satellite mission-control subsystem functions. The software is supplied in a zip file that contains LabVIEW VI files, which provide various functions of the PCI-SpaceWire card, as well as higher-link-level functions. The VIs are suitably named according to the matching function names in the driver manual. A number of test programs also are provided to exercise various functions.

  15. First test results of TRD prototypes for CBM with alternating wires

    Energy Technology Data Exchange (ETDEWEB)

    Dillenseger, Pascal; Glaessel, Susanne; Roether, Florian [Institut fuer Kernphysik Frankfurt (Germany)

    2014-07-01

    The CBM (Compressed Baryonic Matter) at FAIR will be dedicated to the exploration of the QCD phase diagram in the region of high net-baryon densities using heavy-ion collisions. The CBM Transition-Radiation Detector (TRD) has to deliver a good tracking and electron identification performance in an unprecedented high particle-density environment. A thin Multi-Wire Proportional Chamber (MWPC) without drift region delivers the required fast detector response for the expected high signal rates. One key challenge is to achieve stability of the gas gain. To reduce its sensitivity to cathode deformations, an alternating wire structure, as proposed for the ALICE VHMPID (Nucl. Instrum. Meth. A698 (2013) 11-18), is exploited. Field wires are introduced between the sense wires to improve the field line distribution and its stability. An asymmetric structure, i.e. one cathode is closer to the wire plane than the other, provides fast removal of positive ions. Prototypes with standard and alternating field wires, symmetric and asymmetric structure, and different pad planes have been build and tested with an {sup 55}Fe source to measure position and pressure dependent gain variations.

  16. Flexible wire-shaped strain sensor from cotton thread for human health and motion detection

    Science.gov (United States)

    Li, Yuan-Qing; Huang, Pei; Zhu, Wei-Bin; Fu, Shao-Yun; Hu, Ning; Liao, Kin

    2017-03-01

    In this work, a wire-shaped flexible strain sensor was fabricated by encapsulating conductive carbon thread (CT) with polydimethylsiloxane (PDMS) elastomer. The key strain sensitive material, CT, was prepared by pyrolysing cotton thread in N2 atmosphere. The CT/PDMS composite wire shows a typical piezo-resistive behavior with high strain sensitivity. The gauge factors (GF) calculated at low strain of 0-4% and high strain of 8-10% are 8.7 and 18.5, respectively, which are much higher than that of the traditional metallic strain sensor (GF around 2). The wire-shaped CT/PDMS composite sensor shows excellent response to cyclic tensile loading within the strain range of 0-10%, the frequency range of 0.01-10 Hz, to up to 2000 cycles. The potential of the wire senor as wearable strain sensor is demonstrated by the finger motion and blood pulse monitoring. Featured by the low costs of cotton wire and PDMS resin, the simple structure and fabrication technique, as well as high performance with miniaturized size, the wire-shaped sensor based on CT/PDMS composite is believed to have a great potential for application in wearable electronics for human health and motion monitoring.

  17. Effects of load voltage on voltage breakdown modes of electrical exploding aluminum wires in air

    Science.gov (United States)

    Wu, Jian; Li, Xingwen; Yang, Zefeng; Wang, Kun; Chao, Youchuang; Shi, Zongqian; Jia, Shenli; Qiu, Aici

    2015-06-01

    The effects of the load voltage on the breakdown modes are investigated in exploding aluminum wires driven by a 1 kA, 0.1 kA/ns pulsed current in air. From laser probing images taken by laser shadowgraphy, schlieren imaging, and interferometry, the position of the shockwave front, the plasma channel, and the wire core edge of the exploding product can be determined. The breakdown mode makes a transition from the internal mode, which involves breakdown inside the wire core, to the shunting mode, which involves breakdown in the compressed air, with decreasing charging voltage. The breakdown electrical field for a gaseous aluminum wire core of nearly solid density is estimated to be more than 20 kV/cm, while the value for gaseous aluminum of approximately 0.2% solid density decreases to 15-20 kV/cm. The breakdown field in shunting mode is less than 20 kV/cm and is strongly affected by the vaporized aluminum, the desorbed gas, and the electrons emitted from the wire core during the current pause. Ohmic heating during voltage collapses will induce further energy deposition in the current channel and thus will result in different expansion speeds for both the wire core and the shockwave front in the different modes.

  18. Evolution of surface defects in platinum alloy wire under drawing

    Science.gov (United States)

    Loginov, Yu. N.; Pervukhin, A. E.; Babailov, N. A.

    2017-12-01

    The shape and chemical composition of particles polluting the surface of ultrafine wire made of the platinum Pt92.5Pd4Rh3.5 alloy has been revealed by electron microscopy and microspectral analysis. The phenomenon of the appearance of pores in the particles, which are elongated in the direction of drawing, has been discovered. The problem of calculating the stress-strain state is stated by the finite element method. After solving the problem, it is demonstrated that the appearance of additional defects is related to the proportion of stresses in the scheme of metal forming by drawing.

  19. Utility of the electronic information resource UpToDate for clinical decision-making at bedside rounds.

    Science.gov (United States)

    Phua, J; See, K C; Khalizah, H J; Low, S P; Lim, T K

    2012-02-01

    Clinical questions often arise at daily hospital bedside rounds. Yet, little information exists on how the search for answers may be facilitated. The aim of this prospective study was, therefore, to evaluate the overall utility, including the feasibility and usefulness of incorporating searches of UpToDate, a popular online information resource, into rounds. Doctors searched UpToDate for any unresolved clinical questions during rounds for patients in general medicine and respiratory wards, and in the medical intensive care unit of a tertiary teaching hospital. The nature of the questions and the results of the searches were recorded. Searches were deemed feasible if they were completed during the rounds and useful if they provided a satisfactory answer. A total of 157 UpToDate searches were performed during the study period. Questions were raised by all ranks of clinicians from junior doctors to consultants. The searches were feasible and performed immediately during rounds 44% of the time. Each search took a median of three minutes (first quartile: two minutes, third quartile: five minutes). UpToDate provided a useful and satisfactory answer 75% of the time, a partial answer 17% of the time and no answer 9% of the time. It led to a change in investigations, diagnosis or management 37% of the time, confirmed what was originally known or planned 38% of the time and had no effect 25% of the time. Incorporating UpToDate searches into daily bedside rounds was feasible and useful in clinical decision-making.

  20. Experimental setup to detect superconducting wire motion

    Science.gov (United States)

    Ruwali, K.; Yamanaka, A.; Teramoto, Y.; Nakanishi, K.; Hosoyama, K.

    2009-04-01

    An experimental setup was designed and fabricated to study superconducting wire motion under the influence of electromagnetic force. Experiments were conducted at 4.2 K by varying the experimental conditions such as the tension to the superconducting wire and different insulating materials at the interface of the superconducting wire and head part. The insulating materials used in the experiments were polyimide film and a high strength polyethylene fiber cloth, Dyneema. Details of the experimental setup and the test results are reported in this paper.

  1. Lasing from a single quantum wire

    OpenAIRE

    Hayamizu, Yuhei; Yoshita, Masahiro; Watanabe, Shinichi; Akiyama, Hidefumi; Pfeiffer, Loren N.; West, Ken W.

    2002-01-01

    A laser with an active volume consisting of only a single quantum wire in the 1-dimensional (1-D) ground state is demonstrated. The single wire is formed quantum-mechanically at the T-intersection of a 14 nm Al_{0.07}Ga_{0.93}As quantum well and a 6 nm GaAs quantum well, and is embedded in a 1-D single-mode optical waveguide. We observe single-mode lasing from the quantum wire ground state by optical pumping. The laser operates from 5 to 60 K, and has a low threshold pumping power of 5 mW at ...

  2. Experimental setup to detect superconducting wire motion

    Directory of Open Access Journals (Sweden)

    K. Ruwali

    2009-04-01

    Full Text Available An experimental setup was designed and fabricated to study superconducting wire motion under the influence of electromagnetic force. Experiments were conducted at 4.2 K by varying the experimental conditions such as the tension to the superconducting wire and different insulating materials at the interface of the superconducting wire and head part. The insulating materials used in the experiments were polyimide film and a high strength polyethylene fiber cloth, Dyneema. Details of the experimental setup and the test results are reported in this paper.

  3. Magnetoimpedance simulations in wires and tubes

    CERN Document Server

    Munoz, J L; Kurlyandskaya, G V; Garcia-Arribas, A

    2002-01-01

    Numerical computations have been used to study the magnetoimpedance (MI) effect in magnetic wires and microtubes. Two kinds of wires have been investigated. In the first case, a typical amorphous wire with a core-shell structure is simulated, considering the different magnetization curve of each layer, and in the second case, a non-magnetic wire with a thin deposited layer of magnetic material is studied. The results of the simulations agree in both cases with the experimental behavior usually found for these samples. They also allow us to explain such features as MI saturation and the influence of the resistivities of the conductive and magnetic layers in microtubes, that can improve MI-based devices.

  4. Beam Profiling through Wire Chambing Tracking

    CERN Document Server

    Nash, W

    2013-01-01

    This note describes the calibration of the Delay Wire Chambers (DWCs) used during test runs of CALICE’s Tungsten Digital Hadron Calorimeter (W-DHCAL) prototype in CERN’s SPS beam line (10 – 300 GeV).

  5. Wire core reactor for nuclear thermal propulsion

    Science.gov (United States)

    Harty, Richard B.; Brengle, Robert G.

    1993-01-01

    Studies have been performed of a compact high-performance nuclear rocket reactor that incorporates a tungsten alloy wire fuel element. This reactor, termed the wire core reactor, can deliver a specific impulse of 1,000 s using an expander cycle and a nozzle expansion ratio of 500 to 1. The core is constructed of layers of 0.8-mm-dia fueled tungsten wires wound over alternate layers of spacer wires, which forms a rugged annular lattice. Hydrogen flow in the core is annular, flowing from inside to outside. In addition to the concepts compact size and good heat transfer, the core has excellent power-flow matching features and can resist vibration and thermal stresses during star-up and shutdown.

  6. Wire Bonder: Kulicke and Soffa Model 4526

    Data.gov (United States)

    Federal Laboratory Consortium — Description:CORAL Name: Wire BonderNeeds Description.Scientific Opportunities / Applications:Wedge bonderSemi-automatic and manual modesIndependent Z-axis control,...

  7. Micron Size Laser-Wire System at the ATF Extraction Line, Recent Results and ATF-II Upgrade

    CERN Document Server

    Blair, G A; Boorman, G; Bosco, A; Deacon, L; Karataev, P; Howell, D; Nevay, L J; Corner, L; Delerue, N; Foster, B; Gannaway, F; Newman, M; Senanayake, R; Walczak, R; Hayano, H; Aryshev, A; Terunuma, N; Urakawa, J

    2010-01-01

    The KEK Accelerator test facility (ATF) extraction line laser-wire system has been upgraded last year allowing the measurement of micron scale transverse size electron beams. The most recent measurements using the upgraded system are presented. The ATF-II extraction line design call for the major upgrade of the existing laser-wire system. We report on the hardware upgrades, including the major hardware upgrades to the laser transport, the laser beam diagnostics line, and the mechanical control systems.

  8. Comprehensive evaluation of electronic medical record system use and user satisfaction at five low-resource setting hospitals in ethiopia.

    Science.gov (United States)

    Tilahun, Binyam; Fritz, Fleur

    2015-05-25

    Electronic medical record (EMR) systems are increasingly being implemented in hospitals of developing countries to improve patient care and clinical service. However, only limited evaluation studies are available concerning the level of adoption and determinant factors of success in those settings. The objective of this study was to assess the usage pattern, user satisfaction level, and determinants of health professional's satisfaction towards a comprehensive EMR system implemented in Ethiopia where parallel documentation using the EMR and the paper-based medical records is in practice. A quantitative, cross-sectional study design was used to assess the usage pattern, user satisfaction level, and determinant factors of an EMR system implemented in Ethiopia based on the DeLone and McLean model of information system success. Descriptive statistical methods were applied to analyze the data and a binary logistic regression model was used to identify determinant factors. Health professionals (N=422) from five hospitals were approached and 406 responded to the survey (96.2% response rate). Out of the respondents, 76.1% (309/406) started to use the system immediately after implementation and user training, but only 31.7% (98/309) of the professionals reported using the EMR during the study (after 3 years of implementation). Of the 12 core EMR functions, 3 were never used by most respondents, and they were also unaware of 4 of the core EMR functions. It was found that 61.4% (190/309) of the health professionals reported over all dissatisfaction with the EMR (median=4, interquartile range (IQR)=1) on a 5-level Likert scale. Physicians were more dissatisfied (median=5, IQR=1) when compared to nurses (median=4, IQR=1) and the health management information system (HMIS) staff (median=2, IQR=1). Of all the participants, 64.4% (199/309) believed that the EMR had no positive impact on the quality of care. The participants indicated an agreement with the system and information

  9. Structural Parameters and Strengthening Mechanisms in Cold-Drawn Pearlitic Steel Wires

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andy; Huang, Xiaoxu

    2012-01-01

    Pearlitic steel wires have a nanoscale structure and a strength which can reach 5 GPa. In order to investigate strengthening mechanisms, structural parameters including interlamellar spacing, dislocation density and cementite decomposition, have been analyzed by transmission electron microscopy...... estimated based on an assumption of linear additivity of the three contributions....

  10. 7 CFR 1755.860 - RUS specification for filled buried wires.

    Science.gov (United States)

    2010-01-01

    ... conductors which are used within the RUS program are provided in the following table: American Wire Gauge... American National Standards Institute/Electronic Industries Association (ANSI/EIA) 359-A-84, EIA Standard... Materials specifications (ASTM) A 505-87, Standard Specification for Steel, Sheet and Strip, Alloy, Hot...

  11. Surface energy-mediated construction of anisotropic semiconductor wires with selective crystallographic polarity.

    Science.gov (United States)

    Sohn, Jung Inn; Hong, Woong-Ki; Lee, Sunghoon; Lee, Sanghyo; Ku, JiYeon; Park, Young Jun; Hong, Jinpyo; Hwang, Sungwoo; Park, Kyung Ho; Warner, Jamie H; Cha, SeungNam; Kim, Jong Min

    2014-07-14

    ZnO is a wide band-gap semiconductor with piezoelectric properties suitable for opto-electronics, sensors, and as an electrode material. Controlling the shape and crystallography of any semiconducting nanomaterial is a key step towards extending their use in applications. Whilst anisotropic ZnO wires have been routinely fabricated, precise control over the specific surface facets and tailoring of polar and non-polar growth directions still requires significant refinement. Manipulating the surface energy of crystal facets is a generic approach for the rational design and growth of one-dimensional (1D) building blocks. Although the surface energy is one basic factor for governing crystal nucleation and growth of anisotropic 1D structures, structural control based on surface energy minimization has not been yet demonstrated. Here, we report an electronic configuration scheme to rationally modulate surface electrostatic energies for crystallographic-selective growth of ZnO wires. The facets and orientations of ZnO wires are transformed between hexagonal and rectangular/diamond cross-sections with polar and non-polar growth directions, exhibiting different optical and piezoelectrical properties. Our novel synthetic route for ZnO wire fabrication provides new opportunities for future opto-electronics, piezoelectronics, and electronics, with new topological properties.

  12. Conductance Switching and Organization of Two Structurally Related Molecular Wires on Gold

    NARCIS (Netherlands)

    Stan, Razvan C.; Kros, Alexander; Akkilic, Namik; Appel, Jeroen; Sanghamitra, Nusrat J.M.

    2015-01-01

    The self-assembly and electron transfer properties of adsorbed organic molecules are of interest for the construction of miniaturized molecular circuitries. We have investigated with scanning probe microscopy the self-organization of two structurally related molecular wires embedded within a

  13. 47 CFR 32.2321 - Customer premises wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Customer premises wiring. 32.2321 Section 32... Customer premises wiring. (a) This account shall include all amounts transferred from the former Account 232, Station Connections, inside wiring subclass. (b) Embedded Customer Premises Wiring is that...

  14. Cobalt chromium sublaminar wires for spinal deformity surgery.

    Science.gov (United States)

    Cluck, Michael W; Skaggs, David L

    2006-09-01

    Biomechanical analysis and retrospective chart review. To determine the mechanical properties of cobalt chromium alloy wires and review the clinical application of the wires as sublaminar implants to correct spinal deformity. Sublaminar wires are commonly used as anchors in spinal deformity surgery. In stainless steel instrumentation systems, single strand wires (Luque wires) may be retightened over time to take advantage of stress relaxation while correcting spinal deformity. Because of the mechanical properties of titanium, solid titanium wires are not used as sublaminar wires. Cobalt chromium alloy is a titanium compatible alloy that can be twisted in a similar fashion to stainless steel sublaminar wires. Comparative tensile tests were performed using cobalt chromium alloy wires and Luque stainless steel wires. In addition, 22 consecutive posterior spinal fusions for idiopathic scoliosis were performed using cobalt chromium alloy wires as sublaminar implants. Yield and ultimate tensile loads for the cobalt chromium alloy wires are on average 66% (P cobalt chromium alloy wires were used as sublaminar implants. Mean preoperative lumbar curve was 52 degrees +/- 14 degrees , which corrected to 17 degrees +/- 8 degrees (68% correction, P cobalt chromium alloy wire over steel wire include greater tensile strength and titanium compatibility. Cobalt chromium alloy solid wires may be used as sublaminar implants with titanium spinal instrumentation with excellent clinical results.

  15. Audio wiring guide how to wire the most popular audio and video connectors

    CERN Document Server

    Hechtman, John

    2012-01-01

    Whether you're a pro or an amateur, a musician or into multimedia, you can't afford to guess about audio wiring. The Audio Wiring Guide is a comprehensive, easy-to-use guide that explains exactly what you need to know. No matter the size of your wiring project or installation, this handy tool provides you with the essential information you need and the techniques to use it. Using The Audio Wiring Guide is like having an expert at your side. By following the clear, step-by-step directions, you can do professional-level work at a fraction of the cost.

  16. A Magnetic Sensor with Amorphous Wire

    Directory of Open Access Journals (Sweden)

    Dongfeng He

    2014-06-01

    Full Text Available Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  17. Graphene wire medium: Homogenization and application

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Chigrin, Dmitry N.; Lavrinenko, Andrei

    2012-01-01

    In this contribution we analyze numerically the optical properties of the graphene wire medium, which unit cell consists of a stripe of graphene embedded into dielectric. We propose a simple method for retrieval of the isofrequency contour and effective permittivity tensor. As an example...... of the graphene wire medium application we demonstrate a reconfigurable hyperlens for the terahertz subwavelength imaging capable of resolving two sources with separation λ0/5 in the far-field....

  18. Subwavelength wire array metamaterial microwave cavities

    Science.gov (United States)

    Al-Rubaiee, M.; Alchalaby, A.; Al-Janabi, H.

    2018-01-01

    Wire array metamaterial cavities and waveguides can be achieved by changing the resonance frequency of one or more unit cell surrounding by unit cells don't support the resonance for certain frequency and hence obtain signal confinement only on the defect wires. Changing the resonance frequency of one or more unit cell was done in this work by changing the length of the unit cell. We validate our approach in experiment and simulation with electromagnetic waves in the microwave range.

  19. Novel use of the "buddy"wire.

    LENUS (Irish Health Repository)

    O'Hare, A

    2008-12-29

    Summary: During interventional procedures the tortuosity of the vasculature hampers catheter stability. The buddy wire may be used to aid and maintain vascular access.We describe a case of acute subarachnoid haemorrhage secondary to dissecting aneurysm of the vertebral artery.We discuss the value of the buddy wire during balloon occlusion of the vertebral artery not as it is typically used, but to actually prevent the balloon repeatedly entering the posterior inferior cerebellar artery during the procedure.

  20. Charge Transport Along Phenylenevinylene Molecular Wires

    OpenAIRE

    Siebbeles, Laurens; Prins, Paulette; Grozema, Ferdinand

    2006-01-01

    Abstract A model to calculate the mobility of charges along molecular wires is presented. The model is based on the tight-binding approximation and combines a quantum mechanical description of the charge with a classical description of the structural degrees of freedom. It is demonstrated that the average mobility of charge carriers along molecular wires can be obtained by time-propagation of states which are initially localised. The model is used to calculate the mobility of charg...

  1. Wiring System Diagnostic Techniques for Legacy Aircraft

    Science.gov (United States)

    2003-02-01

    Reunions des specialistes des techniques de estion du cycle de vie pour vehicules aeriens vieillissants ] To order the complete compilation report, use...Ageing Mechanisms and Control. Specialists’ Meeting on Life Management Techniques for Ageing Air Vehicles [Les mecanismes vieillissants et le controle...be identified. Additionally, wiring failures tend to be intermittent in nature and can take considerable time to isolate. Wire modifications and

  2. A Wire Grid Paraboloid for Large Low Frequency Telescopes

    Science.gov (United States)

    Kuiper, Tom

    2017-05-01

    Planetary magnetic fields are usually studied remotely through their electron cyclotron maser (ECM) emission from electrons trapped in their magnetic fields. Jupiter has been well studied since the 1960's because its strong magnetic field allows emissions up to about 40 MHz to be observed. The emission from Earth and other outer planets is mostly below 1 MHz and can only be observed from space. It is reasonable to assume that most exoplanets with ECM must be observed at low frequencies from space. Even optimistic assumptions about the strength of such emission leads one to conclude that very large filled aperture telescopes, with a diameters of a kilometer or more, will be needed.This paper reports on a study of a copper wire reflector with a diameter of 1 km operating between 100 kHz and 3.75 MHz. It would require 200 kg of 0.5 mm diameter copper wire (AWG 24)) to be lifted to and deployed in space. For aluminum, the mass would be about 100 kg. By optimizing the wire spacing the mass can be reduced to 80% of a simple radial-azimuthal arrangement. A relatively flat reflector (0.6 ≤ f/D ≤ 1.0) needs to be anchored at about 5 points from center to ring along 24 radii. Station-keeping CubeSats could serve as anchors. A total of about 100-120 anchors would be needed for an f/D = 1 reflector, adding 200-300 kg. to the mass of the reflector. It would be possible to carry several such reflectors into space in a single payload.The Deep Space Network is operated by the Jet Propulsion Laboratory, California Institute of Technology, under contract to the National Aeronautics and Space Administration.

  3. Subchannel Analysis of Wire Wrapped SCWR Assembly

    Directory of Open Access Journals (Sweden)

    Jianqiang Shan

    2014-01-01

    Full Text Available Application of wire wrap spacers in SCWR can reduce pressure drop and obtain better mixing capability. As a consequence, the required coolant pumping power is decreased and the coolant temperature profile inside the fuel bundle is flattened which will obviously decrease the peak cladding temperature. The distributed resistance model for wire wrap was developed and implemented in ATHAS subchannel analysis code. The HPLWR wire wrapped assembly was analyzed. The results show that: (1 the assembly with wire wrap can obtain a more uniform coolant temperature profile than the grid spaced assembly, which will result in a lower peak cladding temperature; (2 the pressure drop in a wire wrapped assembly is less than that in a grid spaced assembly, which can reduce the operating power of pump effectively; (3 the wire wrap pitch has significant effect on the flow in the assembly. Smaller Hwire/Drod will result in stronger cross flow a more uniform coolant temperature profile, and also a higher pressure drop.

  4. Induced Voltage in an Open Wire

    Science.gov (United States)

    Morawetz, K.; Gilbert, M.; Trupp, A.

    2017-07-01

    A puzzle arising from Faraday's law has been considered and solved concerning the question which voltage will be induced in an open wire with a time-varying homogeneous magnetic field. In contrast to closed wires where the voltage is determined by the time variance of the magnetic field and the enclosed area, in an open wire we have to integrate the electric field along the wire. It is found that the longitudinal electric field with respect to the wave vector contributes with 1/3 and the transverse field with 2/3 to the induced voltage. In order to find the electric fields the sources of the magnetic fields are necessary to know. The representation of a spatially homogeneous and time-varying magnetic field implies unavoidably a certain symmetry point or symmetry line which depend on the geometry of the source. As a consequence the induced voltage of an open wire is found to be the area covered with respect to this symmetry line or point perpendicular to the magnetic field. This in turn allows to find the symmetry points of a magnetic field source by measuring the voltage of an open wire placed with different angles in the magnetic field. We present exactly solvable models of the Maxwell equations for a symmetry point and for a symmetry line, respectively. The results are applicable to open circuit problems like corrosion and for astrophysical applications.

  5. The technology of testing the safety of steel wire ropes

    Science.gov (United States)

    Zhang, Xiaochun; Hu, Caiwen

    2005-12-01

    To estimate the security of steel wire rope, the broken wire condition, the capability of the rope to bear weight and the state of stress balance of each wire in the steel wire rope were investigated. The wavelet translation method was applied to analyze the signals of magnetic field leakage from the steel wire rope. The result of the time-frequency analysis of the signals can be used to make certain of he position and the amount of the broken wire. Using the static surveillance method as a basis, a dynamic surveillance method was designed to detect the stress balance of the steel wire rope. This technology makes it possible to check the stress condition of each wire on line. It can be concluded that a wavelet translation analysis and the dynamic surveillance technique are effective methods to detect on line and real-time the broken wire and the stress balance of multistrand wire ropes.

  6. Mechanical properties of NiTi and CuNiTi wires used in orthodontic treatment. Part 2: Microscopic surface appraisal and metallurgical characteristics

    Directory of Open Access Journals (Sweden)

    Marco Abdo Gravina

    2014-01-01

    Full Text Available OBJECTIVE: This research aimed at comparing the qualitative chemical compositions and the surface morphology of fracture regions of eight types of Nickel (Ni Titanium (Ti conventional wires, superelastic and heat-activated (GAC, TP, Ormco, Masel, Morelli and Unitek, to the wires with addition of copper (CuNiTi 27oC and 35oC, Ormco after traction test. METHODS: The analyses were performed in a scanning electronic microscope (JEOL, model JSM-5800 LV with EDS system of microanalysis (energy dispersive spectroscopy. RESULTS : The results showed that NiTi wires presented Ni and Ti as the main elements of the alloy with minimum differences in their composition. The CuNiTi wires, however, presented Ni and Ti with a significant percentage of copper (Cu. As for surface morphology, the wires that presented the lowest wire-surface roughness were the superelastic ones by Masel and Morelli, while those that presented the greatest wire-surface roughness were the CuNiTi 27oC and 35oC ones by Ormco, due to presence of microcavity formed as a result of pulling out some particles, possibly of NiTi. 4 The fracture surfaces presented characteristics of ductile fracture, with presence of microcavities. The superelastic wires by GAC and the CuNiTi 27oC and the heat-activated ones by Unitek presented the smallest microcavities and the lowest wire-surface roughness with regard to fracture, while the CuNiTi 35oC wires presented inadequate wire-surface roughness in the fracture region. CONCLUSION: CuNiTi 35oC wires did not present better morphologic characteristics in comparison to the other wires with regard to surfaces and fracture region.

  7. The effect of ZnO nanoparticle coating on the frictional resistance between orthodontic wires and ceramic brackets

    Directory of Open Access Journals (Sweden)

    Ahmad

    2016-06-01

    Full Text Available Background. Any decrease in friction between orthodontic wire and bracket can accelerate tooth movement in the sliding technique and result in better control of anchorage. This study was carried out to evaluate frictional forces by coating orthodontic wires and porcelain brackets with zinc oxide nanoparticles (ZnO. Methods. In this in vitro study, we evaluated a combination of 120 samples of 0.019×0.025 stainless steel (SS orthodontic wires and 22 mil system edgewise porcelain brackets with and without spherical zinc oxide nanoparticles. Spherical ZnO nanoparticles were deposited on wires and brackets by immersing them in ethanol solution and SEM (scanning electron microscope evaluation confirmed the presence of the ZnO coating. The frictional forces were calculated between the wires and brackets in four groups: group ZZ (coated wire and bracket, group OO (uncoated wire and bracket, group ZO (coated wire and uncoated bracket and group OZ (uncoated wire and coated bracket. Kolmogorov-Smirnov, Mann-Whitney and Kruskal-Wallis tests were used for data analysis. Results. The frictional force in ZZ (3.07±0.4 N was the highest (P <0.05, and OZ (2.18±0.5 N had the lowest amount of friction (P <0.05 among the groups. There was no significant difference in frictional forces between the ZO and OO groups (2.65±0.2 and 2.70±0.2 N, respectively. Conclusion. Coating of porcelain bracket surfaces with ZnO nanoparticles can decrease friction in the sliding technique, and wire coating combined with bracket coating is not recommended due to its effect on friction.

  8. 75 FR 60480 - In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire...

    Science.gov (United States)

    2010-09-30

    ... COMMISSION In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire... importation, or the sale within the United States after importation of certain bulk welding wire containers, components thereof, and welding wire by reason of infringement of certain claims of United States Patent Nos...

  9. Use of a tip-edge stage-1 wire to enhance vertical control during straight wire treatment: two case reports.

    Science.gov (United States)

    Taylor, Helen

    2003-02-01

    Vertical control is one of the problems occasionally encountered in Straight wire treatment. Two cases, one with deep overbite and one with anterior open-bite, demonstrate the use of a Tip-Edge stage-1 wire to enhance vertical control in conjunction with Straight wire brackets and superelastic main arch wires.

  10. Effective field theory for the quantum electrodynamics of a graphene wire

    Science.gov (United States)

    Faccioli, P.; Lipparini, E.

    2009-07-01

    We study the low-energy quantum electrodynamics of electrons and holes in a thin graphene wire. We develop an effective field theory (EFT) based on an expansion in p/pT , where pT is the typical momentum of electrons and holes in the transverse direction, while p are the momenta in the longitudinal direction. We show that, to the lowest order in (p/pT) , our EFT theory is formally equivalent to the exactly solvable Schwinger model. By exploiting such an analogy, we find that the ground state of the quantum wire contains a condensate of electron-hole pairs. The excitation spectrum is saturated by electron-hole collective bound states, and we calculate the dispersion law of such modes. We also compute the dc conductivity per unit length at zero chemical potential and find gs(e2)/(h) , where gs=4 is the degeneracy factor.

  11. Randomized Controlled Trial of Electronic Care Plan Alerts and Resource Utilization by High Frequency Emergency Department Users with Opioid Use Disorder

    Directory of Open Access Journals (Sweden)

    Niels Rathlev, MD

    2016-01-01

    Full Text Available Introduction: There is a paucity of literature supporting the use of electronic alerts for patients with high frequency emergency department (ED use. We sought to measure changes in opioid prescribing and administration practices, total charges and other resource utilization using electronic alerts to notify providers of an opioid-use care plan for high frequency ED patients. Methods: This was a randomized, non-blinded, two-group parallel design study of patients who had 1 opioid use disorder and 2 high frequency ED use. Three affiliated hospitals with identical electronic health records participated. Patients were randomized into “Care Plan” versus “Usual Care groups”. Between the years before and after randomization, we compared as primary outcomes the following: 1 opioids (morphine mg equivalents prescribed to patients upon discharge and administered to ED and inpatients; 2 total medical charges, and the numbers of; 3 ED visits, 4 ED visits with advanced radiologic imaging (computed tomography [CT] or magnetic resonance imaging [MRI] studies, and 5 inpatient admissions. Results: A total of 40 patients were enrolled. For ED and inpatients in the “Usual Care” group, the proportion of morphine mg equivalents received in the post-period compared with the pre-period was 15.7%, while in the “Care Plan” group the proportion received in the post-period compared with the pre-period was 4.5% (ratio=0.29, 95% CI [0.07-1.12]; p=0.07. For discharged patients in the “Usual Care” group, the proportion of morphine mg equivalents prescribed in the post-period compared with the pre-period was 25.7% while in the “Care Plan” group, the proportion prescribed in the post-period compared to the pre-period was 2.9%. The “Care Plan” group showed an 89% greater proportional change over the periods compared with the “Usual Care” group (ratio=0.11, 95% CI [0.01-0.092]; p=0.04. Care plans did not change the total charges, or, the numbers

  12. The Analysis of the High Speed Wire Drawing Process of High Carbon Steel Wires Under Hydrodynamic Lubrication Conditions

    Directory of Open Access Journals (Sweden)

    Suliga M.

    2015-04-01

    Full Text Available In this work the analysis of the wire drawing process in hydrodynamic dies has been done. The drawing process of φ5.5 mm wire rod to the final wire of φ1.7 mm was conducted in 12 passes, in drawing speed range of 5-25 m/s. For final wires of φ1.7 mm the investigation of topography of wire surface, the amount of lubricant on the wire surface and the pressure of lubricant in hydrodynamic dies were determined. Additionally, in the work selected mechanical properties of the wires have been estimated.

  13. Power distribution for electron beam welding

    Science.gov (United States)

    Edwards, E.

    1980-01-01

    The power distribution of an electron seam is analyzed. Digital computer techniques are used to evaluate the radial distribution of power detected by a wire probe circulating through the beam. Results are reported.

  14. Trapping of ultracold polar molecules with a thin-wire electrostatic trap.

    Science.gov (United States)

    Kleinert, J; Haimberger, C; Zabawa, P J; Bigelow, N P

    2007-10-05

    We describe the realization of a dc electric-field trap for ultracold polar molecules, the thin-wire electrostatic trap (TWIST). The thin wires that form the electrodes of the TWIST allow us to superimpose the trap onto a magneto-optical trap (MOT). In our experiment, ultracold polar NaCs molecules in their electronic ground state are created in the MOT via photoassociation, achieving a continuous accumulation in the TWIST of molecules in low-field seeking states. Initial measurements show that the TWIST trap lifetime is limited only by the background pressure in the chamber.

  15. Modeling inelastic phonon scattering in atomic- and molecular-wire junctions

    DEFF Research Database (Denmark)

    Paulsson, Magnus; Frederiksen, Thomas; Brandbyge, Mads

    2005-01-01

    Computationally inexpensive approximations describing electron-phonon scattering in molecular-scale conductors are derived from the nonequilibrium Green's function method. The accuracy is demonstrated with a first-principles calculation on an atomic gold wire. Quantitative agreement between...... the full nonequilibrium Green's function calculation and the newly derived expressions is obtained while simplifying the computational burden by several orders of magnitude. In addition, analytical models provide intuitive understanding of the conductance including nonequilibrium heating and provide...... a convenient way of parameterizing the physics. This is exemplified by fitting the expressions to the experimentally observed conductances through both an atomic gold wire and a hydrogen molecule....

  16. Optimal synthesis and characterization of Ag nanofluids by electrical explosion of wires in liquids

    OpenAIRE

    Won Lee Seung; Bang In Cheol; Ju Park Eun; Park Hyung Wook

    2011-01-01

    Abstract Silver nanoparticles were produced by electrical explosion of wires in liquids with no additive. In this study, we optimized the fabrication method and examined the effects of manufacturing process parameters. Morphology and size of the Ag nanoparticles were determined using transmission electron microscopy and field-emission scanning electron microscopy. Size and zeta potential were analyzed using dynamic light scattering. A response optimization technique showed that optimal condit...

  17. There is a Relationship between Resource Expenditures and Reference Transactions in Academic Libraries. A Review of: Dubnjakovic, A. (2012. Electronic resource expenditure and the decline in reference transaction statistics in academic libraries. Journal of Academic Librarianship, 38(2, 94-100. doi:10.1016/j.acalib.2012.01.001

    Directory of Open Access Journals (Sweden)

    Annie M. Hughes

    2013-03-01

    Full Text Available Objective – To provide an analysis of the impact of expenditures on electronic resourcesand gate counts on the increase or decrease in reference transactions.Design – Analysis of results of existing survey data from the National Center for Educational Statistics (NCES 2006 Academic Library Survey(ALS.Setting – Academic libraries in the United States.Subjects – 3925 academic library respondents.Methods – The author chose to use survey data collected from the 2006 ALS conducted bythe NCES. The survey included data on various topics related to academic libraries, but in the case of this study, the author chose to analyze three of the 193 variables included. The three variables: electronic books expenditure, computer hardware and software, and expenditures on bibliographic utilities, were combined into one variable called electronic resource expenditure. Gate counts were also considered as a variable. Electronic resource expenditure was also split as a variable into three groups: low, medium, and high. Multiple regression analysis and general linear modeling, along with tests of reliability, were employed. Main Results – The author determined that low, medium, and high spenders with regard to electronic resources exhibited differences in gate counts, and gate counts have an effect on reference transactions in any given week. Gate counts tend to not have much of an effect on reference transactions for the higher spenders, and higher spenders tend to have a higher number of reference transactions overall. Low spenders have lower gate counts and also a lower amount of reference transactions.Conclusion – The findings from this study show that academic libraries spending more on electronic resources also tend to have an increase with regard to reference transactions. The author also concludes that library spaces are no longer the determining factor with regard to number of reference transactions. Spending more on electronic resources is

  18. Global application of disorders of sex development-related electronic resources: e-learning, e-consultation and e-information sharing.

    Science.gov (United States)

    Muscarella, Miriam; Kranenburg-van Koppen, Laura; Grijpink-van den Biggelaar, Kalinka; Drop, Stenvert L S

    2014-01-01

    The past 20 years have seen proliferation of electronic (e) resources that promote improved understanding of disorders of sex development (DSD): e-learning for physicians and trainees, e-consultation between clinicians, and e-information for families and affected individuals. Recent e-learning advances have emerged from the European Society for Pediatric Endocrinology's online learning portal for current physicians and trainees. Developed with attention to developing clinical competencies incorporating learning theory, and presenting material that represents international best practice, this e-learning portal offers advances in training, making information more accessible for clinicians and trainees. Multiple levels of instruction, authentic case examples, collaborative forums for physicians and trainees, individualized feedback and user-friendly tools represent advances in trainee and physician learning that can take place in any location. e-consultation is an emerging tool that aims to connect physicians with specialists experienced in DSD care. Although it faces logistical challenges, e-consultation carries the potential to improve DSD care, especially in remote areas with limited access to DSD specialists. e-information for families and patients of all ages is widely accessible online, often with focus on DSD biology, medical care, and psychological and social support. e-information tools aid self-management and support of those affected by DSD. Efforts to improve these resources should aim to map information to individual users, incorporate optimally clear nomenclature, and continue as a 'shared enterprise' of clinicians, affected individuals, families and researchers. Improving the quality of DSD-related e-learning and e-information and developing e-consultation carries the potential to transform DSD care and support for patients, families and physicians worldwide. © 2014 S. Karger AG, Basel.

  19. STRS SpaceWire FPGA Module

    Science.gov (United States)

    Lux, James P.; Taylor, Gregory H.; Lang, Minh; Stern, Ryan A.

    2011-01-01

    An FPGA module leverages the previous work from Goddard Space Flight Center (GSFC) relating to NASA s Space Telecommunications Radio System (STRS) project. The STRS SpaceWire FPGA Module is written in the Verilog Register Transfer Level (RTL) language, and it encapsulates an unmodified GSFC core (which is written in VHDL). The module has the necessary inputs/outputs (I/Os) and parameters to integrate seamlessly with the SPARC I/O FPGA Interface module (also developed for the STRS operating environment, OE). Software running on the SPARC processor can access the configuration and status registers within the SpaceWire module. This allows software to control and monitor the SpaceWire functions, but it is also used to give software direct access to what is transmitted and received through the link. SpaceWire data characters can be sent/received through the software interface, as well as through the dedicated interface on the GSFC core. Similarly, SpaceWire time codes can be sent/received through the software interface or through a dedicated interface on the core. This innovation is designed for plug-and-play integration in the STRS OE. The SpaceWire module simplifies the interfaces to the GSFC core, and synchronizes all I/O to a single clock. An interrupt output (with optional masking) identifies time-sensitive events within the module. Test modes were added to allow internal loopback of the SpaceWire link and internal loopback of the client-side data interface.

  20. Forecasting of Corrosion Properties of Steel Wires for Production of Guide Wires for Cardiological Treatment

    National Research Council Canada - National Science Library

    Przondziono, J; Walke, W; Hadasik, E; Młynarski, R

    2013-01-01

    ... of guide wires used in invasive cardiology. The results of static tensile test enabled us to determine the course of flow curve of wires made of X10CrNi 18-8 steel as well as mathematical form of flow stress function...