  1. Wire system ageing assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. (Institute for Energy Technology (IFE) (Norway))

    2009-07-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains the results of experiments performed in collaboration with Tecnatom SA, Spain, to compare several cable condition monitoring techniques including LIRA (LIne Resonance Analysis) (au)

  2. Wire system ageing assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Fantoni, P.F.

    2009-07-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains the results of experiments performed in collaboration with Tecnatom SA, Spain, to compare several cable condition monitoring techniques including LIRA (LIne Resonance Analysis) (au)

  3. Wire system aging assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. [Institutt for energiteknikk, IFE (Norway)

    2007-04-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report contains some test results of a method for wire system condition monitoring, developed at the Halden Reactor Project, called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. (au)

  4. Wire system ageing assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Ekelund, M; Gedde, U.W. (Royal Institute of Technology (KTH). Fibre and Polymer Technology, School of Chemical Science and Engineering, Stockholm (Sweden)); Fantoni, P.F. (Institute for Energy Technology (IFE), Halden (Norway))

    2011-05-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. In this report 3 techniques for cable global ageing assessment were tested and evaluated. The EAB technique is a destructive, local technique that is often used as a reference for other methods. The indenter is a local, in-situ mechanical technique that is currently quite often used in NPPs. LIRA is an electrical method, full line, in-situ. LIRA correlated quite well with EAB and both tend to flatten when the ageing time reaches 40 years. The only cable type that was difficult to assess for all the 3 methods was the medium type in air environment. These tests considered only thermal ageing, up to 50 years and should be completed by considering also gamma irradiation ageing. (Author)

  5. Wire system ageing assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Ekelund, M; Gedde, U.W.; Fantoni, P.F.

    2011-05-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. In this report 3 techniques for cable global ageing assessment were tested and evaluated. The EAB technique is a destructive, local technique that is often used as a reference for other methods. The indenter is a local, in-situ mechanical technique that is currently quite often used in NPPs. LIRA is an electrical method, full line, in-situ. LIRA correlated quite well with EAB and both tend to flatten when the ageing time reaches 40 years. The only cable type that was difficult to assess for all the 3 methods was the medium type in air environment. These tests considered only thermal ageing, up to 50 years and should be completed by considering also gamma irradiation ageing. (Author)

  6. Wire system aging assessment and condition monitoring (WASCO)

    International Nuclear Information System (INIS)

    Fantoni, P.F.; Nordlund, A.

    2006-04-01

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report describes a method for wire system condition monitoring, developed at the Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. LIRA is composed of a signal generator, a signal analyser and a simulator that can be used to simulate several failure/degradation scenarios and assess the accuracy and sensitivity of the LIRA system. Chapter 5 of this report describes an complementary approach based on positron measurement techniques, used widely in defect physics due to the high sensitivity to micro defects, in particular open volume defects. This report describes in details these methodologies, the results of field experiments and the proposed future work. (au)

  7. Wire system aging assessment and condition monitoring (WASCO)

    Energy Technology Data Exchange (ETDEWEB)

    Fantoni, P.F. [Institutt for energiteknikk (Norway); Nordlund, A. [Chalmers Univ. of Technology (Sweden)

    2006-04-15

    Nuclear facilities rely on electrical wire systems to perform a variety of functions for successful operation. Many of these functions directly support the safe operation of the facility; therefore, the continued reliability of wire systems, even as they age, is critical. Condition Monitoring (CM) of installed wire systems is an important part of any aging program, both during the first 40 years of the qualified life and even more in anticipation of the license renewal for a nuclear power plant. This report describes a method for wire system condition monitoring, developed at the Halden Reactor Project, which is based on Frequency Domain Reflectometry. This method resulted in the development of a system called LIRA (LIne Resonance Analysis), which can be used on-line to detect any local or global changes in the cable electrical parameters as a consequence of insulation faults or degradation. LIRA is composed of a signal generator, a signal analyser and a simulator that can be used to simulate several failure/degradation scenarios and assess the accuracy and sensitivity of the LIRA system. Chapter 5 of this report describes an complementary approach based on positron measurement techniques, used widely in defect physics due to the high sensitivity to micro defects, in particular open volume defects. This report describes in details these methodologies, the results of field experiments and the proposed future work. (au)

  8. Eliminating a Major Cause of Wire Drawing Breakage in A-15 High-Field Superconductors

    International Nuclear Information System (INIS)

    Austen, Alfred R.

    2003-01-01

    Eliminating a Major Cause of Wire Drawing Breakage in A-15 High-Field Superconductors Phase 1 Summary Purpose of the research: The Phase 1 goal was to make a significant improvement in the wire drawing technology used for difficult to draw superconductor precursor composites. Many ductile Nb-Al and Nb-Sn precursor wire composites have experienced the onset of wire drawing breakage at about 1.5 mm diameter. Phase 1 focused on evaluating the role that precision rigid guidance of the wire into the drawing die and the hydrostatic stress state at the die entrance played in preventing wire breakage. Research carried out: The research performed depended upon the construction of both a mechanical wire guide and a hydrostatic pressure stiffened wire guidance system. Innovare constructed the two wire guidance systems and tested them for their ability to reduce wire drawing breakage. One set of hardware provided rigid alignment of the wires to their wire drawing die axes within 0.35 degrees using ''hydrostatic pressure stiffening'' to enable the precision guidance strategy to be implemented for these highly flexible small diameter wires. This apparatus was compared to a guide arrangement that used short span mechanical guide alignment with a misalignment limit of about 0.75 degrees. Four A-15 composite wires with breakage histories were drawn to evaluate the use of these wire guiding systems to reduce and/or eliminate wire breakage. Research findings and results: In Phase 1, a breakthrough in wire drawing technology for A-15 superconductor composites was achieved by dramatically limiting or eliminating breakage in four different A-15 composite precursor wire designs during the drawing of these very desirable composites that previously could not be drawn to near final size. Research results showed that the proposed Phase 1 mechanical wire guides were sufficiently effective and successful in eliminating breakage when used along with other advanced wire drawing technology to

  9. Proportional counters aged anode wire recovering using an 80%CF4 + 20%CO2 gas mixture

    CERN Document Server

    Gavrilov, Gennady; Conti, Richard; Fetisov, Andrey; Maysuzenko, Dmitry; Shvecova, Natalia; Vakhtel, Victor

    2011-01-01

    A technique to recover a gas proportional counter having an aged anode wire using a glow discharge in an 80%CF4 + 20%CO2 gas mixture has been developed and tested. Studies of aging effects were carried out under sustained irradiation by an intense 90Sr -source of the straw proportional counters operated with a 60%Ar + 30%CO2 + 10%CF4 gas mixture. Special attention was paid to the aging mechanism of the anode wires. Our experience showed that using a given gas mixture the swelling of the anode wires is a typical mode of aging that leads to degradation of the gas gain. The proposed method of recovery provided a complete restoration of the gas gain and the signal amplitude in the damaged zone of the wire. SEM/XEM analysis confirmed successful cleaning WOx deposits from the wire surface. The application of this method to recover the aged gaseous detectors in real experimental conditions is discussed.

  10. Aging, tumor suppression and cancer: High-wire act!

    Energy Technology Data Exchange (ETDEWEB)

    Campisi, Judith

    2004-08-15

    Evolutionary theory holds that aging is a consequence of the declining force of natural selection with age. We discuss here the evidence that among the causes of aging in complex multicellular organisms, such as mammals, is the antagonistically pleiotropic effects of the cellular responses that protect the organism from cancer. Cancer is relatively rare in young mammals, owing in large measure to the activity of tumor suppressor mechanisms. These mechanisms either protect the genome from damage and/or mutations, or they elicit cellular responses--apoptosis or senescence--that eliminate or prevent the proliferation of somatic cells at risk for neoplastic transformation.We focus here on the senescence response, reviewing its causes, regulation and effects. In addition, we describe recent data that support the idea that both senescence and apoptosis may indeed be the double-edged swords predicted by the evolutionary hypothesis of antagonistic pleiotropy--protecting organisms from cancer early in life, but promoting aging phenotypes, including late life cancer, in older organisms.

  11. Renal Aging: Causes and Consequences.

    Science.gov (United States)

    O'Sullivan, Eoin D; Hughes, Jeremy; Ferenbach, David A

    2017-02-01

    Individuals age >65 years old are the fastest expanding population demographic throughout the developed world. Consequently, more aged patients than before are receiving diagnoses of impaired renal function and nephrosclerosis-age-associated histologic changes in the kidneys. Recent studies have shown that the aged kidney undergoes a range of structural changes and has altered transcriptomic, hemodynamic, and physiologic behavior at rest and in response to renal insults. These changes impair the ability of the kidney to withstand and recover from injury, contributing to the high susceptibility of the aged population to AKI and their increased propensity to develop subsequent progressive CKD. In this review, we examine these features of the aged kidney and explore the various validated and putative pathways contributing to the changes observed with aging in both experimental animal models and humans. We also discuss the potential for additional study to increase understanding of the aged kidney and lead to novel therapeutic strategies. Copyright © 2017 by the American Society of Nephrology.

  12. Test of the wire ageing induced by radiation for the CMS barrel muon chamber

    CERN Document Server

    Conti, Enrico

    2000-01-01

    We have carried out laboratory test to measure the ageing of a wire tube due to pollutant outgassed by various materials. The tested materials are those used in the muon barrel drift tubes. An X-ray gun irradiated the test tube to accelerate the ageing process. No ageing effect has been measured for a period equivalent to 10 years of operation at LHC.

  13. Aging epigenetics: causes and consequences.

    Science.gov (United States)

    Huidobro, Covadonga; Fernandez, Agustin F; Fraga, Mario F

    2013-01-01

    Growth and development of higher organisms are regulated by the orchestrated change of epigenetic marks over time. In addition, there is also an epigenetic variation without any apparent role in development that is thought to be the result of the stochastic accumulation of epigenetic errors. The process depends on genetic and environmental factors and, when it takes place in adult stem cells, it could play an important role in aging, although the underlying molecular mechanisms are still largely unknown. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. Tests of the wire ageing induced by radiation in the barrel muon chambers of the CMS experiment at LHC

    International Nuclear Information System (INIS)

    Conti, E.; Ballarini, R.; Gasparine, F.

    1999-01-01

    In CMS the barrel muon detectors are drift tubes (DT) filled with Ar/CO 2 gas. Materials of the DT in contact with the gas can outgas pollutant substances during irradiation which may cause a loss of gain or a worsening of the time resolution (wire ageing) during the multiplication process. This article presents the laboratory tests performed to verify that the materials used in DT do not induce wire ageing. The tests concern all the materials inside the DT which are in contact with the gas: 1) mylar tape with glue based on reticulated silicon polymers, 2) Al tape with mono-acrylic glue, 3) bare FR4 boards for HV, and 4) complete FR4 boards for HV (with cables, resistors, capacitors and glue). Both Al and mylar are known to be safe from the point of view of ageing, so the tests concern essentially the glues. For all the above materials, the result is negative, it means that no change of the wire gain has been measured within a few percents which is the sensitivity of the apparatus. (A.C.)

  15. Test of the wire ageing induced by radiation for the CMS barrel muon chambers

    CERN Document Server

    Conti, E

    2001-01-01

    We have carried out laboratory tests to measure the ageing of a wire tube due to pollutants outgassed by various materials. The tested materials are those used in the barrel muon drift tubes of the CMS experiment at LHC. An X-ray gun irradiated the test tube to accelerate the ageing process. No ageing effect has been measured for a period equivalent to 10 years of operation at LHC. (15 refs).

  16. Functional fatigue recovery of superelastic cycled NiTi wires based on near 100 °C aging treatments

    Directory of Open Access Journals (Sweden)

    Isalgue Antonio

    2015-01-01

    Full Text Available Functional fatigue affecting superelastic behaviour of NiTi wires includes an accumulation of residual strain and an uneven decrement of transformation stress on cycling. Although this evolution is observed to diminish asymptotically, it represents an important loss in the maximum recoverable strain level and in the hysteretic dissipative capacity of the material. In this work, the effect of moderate temperature aging treatment on the functionally degraded material properties was studied with two experimental setups. NiTi pseudoelastic wire samples of 0.5 and 2.46 mm diameter were subjected to different cycling programs intercalated by aging treatments of different durations up to 48 h at 100°C. Results show that important levels of recovery on the residual strains and the transformation stresses were attained after the aging treatments. The analysis indicates that the characteristics of the recovered cycles are rather independent from the treatment duration and from the reached condition before each treatment.

  17. Causes of death of women in the reproductive age group

    Directory of Open Access Journals (Sweden)

    A Mustapha

    2011-01-01

    Conclusion: Infectious and parasitic diseases especially HIV/AIDS and tuberculosis were the leading causes of death of women in the reproductive age group contributing significantly to maternal mortality, which exerts a heavy toll on survival of women in this age group. Strategies to comprehensively address the reproductive health problems of women should be instituted.

  18. Effect of ageing on mechanical and impact properties of non-quenched and tempered steel wire strengthened by cold forming

    Science.gov (United States)

    Mao, X. Y.; Zhao, X. M.; Wang, Z. Z.; Cai, L.; Bai, Y. Q.

    2014-03-01

    The effect of ageing on the mechanical and impact properties of non-quenched and tempered steel wire strengthened by cold forming to an area reduction of 25.5% was investigated by tensile testing, charpy impact tests and scanning electronic microscopy. It was found that when the specimen was aged at 300 °C for 2 h, its tensile strength, yield strength, elongation and impact absorption energy increased by 10.8, 18.1, 44.8 and 19.6%, respectively. In addition the ductile-brittle transition temperature decreased by 5 °C. These improved properties are attributed to the decreasing dislocation density, the formation of sub-grains in a stable condition and the uniform dispersion of a fine precipitation phase during the ageing treatment.

  19. Evolution of carbon distribution and mechanical properties during the static strain ageing of heavily drawn pearlitic steel wires

    International Nuclear Information System (INIS)

    Lamontagne, A.; Massardier, V.; Sauvage, X.; Kléber, X.; Mari, D.

    2016-01-01

    The static strain ageing of heavily cold-drawn pearlitic steel wires was investigated using both global techniques and local techniques (Atom Probe Tomography (APT)), in order to highlight how the cold-drawn destabilized microstructure returns to a more stable state during post-drawing treatments between 20 °C and 150 °C. The global techniques (thermoelectric power, differential scanning calorimetry) clearly showed that ageing occurs in three successive ageing stages and is due to a redistribution of the carbon atoms coming from the strain-induced cementite dissolution. The first ageing stage was unambiguously attributed to the carbon segregation to the defects, while the second and third stages were interpreted as being due to the precipitation of intermediate carbides (2nd stage) and cementite (3rd stage). The true strain was not found to significantly affect the ageing kinetics and mechanisms but appeared to play a role in the amount of carbon atoms involved in the different ageing stages. APT analyses confirmed that ageing is governed by the carbon depletion of strain-induced supersaturated ferrite. The strengthening mechanisms associated with the different ageing stages were also discussed.

  20. Evolution of carbon distribution and mechanical properties during the static strain ageing of heavily drawn pearlitic steel wires

    Energy Technology Data Exchange (ETDEWEB)

    Lamontagne, A. [Univ Lyon, INSA Lyon, MATEIS – UMR CNRS 5510, Bât. St Exupéry, 25 Avenue Jean Capelle, F-69621 Villeurbanne Cedex (France); Massardier, V., E-mail: veronique.massardier@insa-lyon.fr [Univ Lyon, INSA Lyon, MATEIS – UMR CNRS 5510, Bât. St Exupéry, 25 Avenue Jean Capelle, F-69621 Villeurbanne Cedex (France); Sauvage, X. [University of Rouen, GPM, UMR CNRS 6634, BP 12, Avenue de l’Université, 76801 Saint-Etienne du Rouvray (France); Kléber, X. [Univ Lyon, INSA Lyon, MATEIS – UMR CNRS 5510, Bât. St Exupéry, 25 Avenue Jean Capelle, F-69621 Villeurbanne Cedex (France); Mari, D. [Institute of Condensed Matter Physics, Ecole Polytechnique Fédérale de Lausanne, Station 3, Lausanne CH-1015 (Switzerland)

    2016-06-14

    The static strain ageing of heavily cold-drawn pearlitic steel wires was investigated using both global techniques and local techniques (Atom Probe Tomography (APT)), in order to highlight how the cold-drawn destabilized microstructure returns to a more stable state during post-drawing treatments between 20 °C and 150 °C. The global techniques (thermoelectric power, differential scanning calorimetry) clearly showed that ageing occurs in three successive ageing stages and is due to a redistribution of the carbon atoms coming from the strain-induced cementite dissolution. The first ageing stage was unambiguously attributed to the carbon segregation to the defects, while the second and third stages were interpreted as being due to the precipitation of intermediate carbides (2nd stage) and cementite (3rd stage). The true strain was not found to significantly affect the ageing kinetics and mechanisms but appeared to play a role in the amount of carbon atoms involved in the different ageing stages. APT analyses confirmed that ageing is governed by the carbon depletion of strain-induced supersaturated ferrite. The strengthening mechanisms associated with the different ageing stages were also discussed.

  1. The early detection and management of unstable concentric closed reduction of DDH with percutaneous K-wire fixation in infants 6 to 12 months of age.

    Science.gov (United States)

    Alsiddiky, Abdul Monem Mohamed; Bakarman, Khalid Abdulla; Alzain, Kholoud Omar; Aljassir, Fawzi Fahad; Al-Ahaideb, Abdulaziz Suliman; Kremli, Mamoun Khalid; Zamzam, Mohammed Medhat; Mervyn Letts, Robert

    2012-01-01

    In some infants with developmental dysplasia of the hip, concentric closed reduction, although initially achievable, cannot be maintained even by casting because of a deficient posterior acetabular wall. Usually, these hips will redislocate in the cast and a rereduction will be necessary, often requiring an open reduction subsequently. A 3-year retrospective review of 88 infants, (M/F; 14/74) 6 to 12 months of age with 124 dislocated hips, was conducted to assess the efficacy of percutaneous Kirschner wire fixation in achieving permanent hip stability. A "hip-at-risk" instability test was developed to detect potentially unstable hips at the time of closed reduction that might redislocate in the hip spica cast, and these hips were stabilized with a percutaneous K-wire through the greater trochanter into the pelvic bone. The hip instability test was positive in 27 hips and negative in 97. Percutaneous K-wire fixation was used to stabilize 21 hips with a positive hip instability test. All 21 unstable hips that were stabilized with the K-wire technique maintained their concentric reduction and went on to stable development. No K-wire breakage was encountered and only 1 superficial pin tract infection occurred. K-wire stabilization of unstable closed reductions is a safe, reliable technique for maintaining concentric hip reduction in infants 6 to 12 months of age with developmental dislocation of the hips. Level II retrospective study.

  2. Senescence and aging: Causes, consequences, and therapeutic avenues.

    Science.gov (United States)

    McHugh, Domhnall; Gil, Jesús

    2018-01-02

    Aging is the major risk factor for cancer, cardiovascular disease, diabetes, and neurodegenerative disorders. Although we are far from understanding the biological basis of aging, research suggests that targeting the aging process itself could ameliorate many age-related pathologies. Senescence is a cellular response characterized by a stable growth arrest and other phenotypic alterations that include a proinflammatory secretome. Senescence plays roles in normal development, maintains tissue homeostasis, and limits tumor progression. However, senescence has also been implicated as a major cause of age-related disease. In this regard, recent experimental evidence has shown that the genetic or pharmacological ablation of senescent cells extends life span and improves health span. Here, we review the cellular and molecular links between cellular senescence and aging and discuss the novel therapeutic avenues that this connection opens. © 2018 McHugh and Gil.

  3. Endogenous oxidants as a cause of aging and cancer

    International Nuclear Information System (INIS)

    Ames, B.N.

    1992-01-01

    Daily endogenous oxidative DNA damage is enormous. A normal young rat cell has about 10 6 oxidative adducts and this number increases with age. About 10 5 new oxidative adducts per cell are formed every day, most of which are repaired. These are the same type of adducts that are produced by radiation, an oxidative mutagen. The authors conclude that endogenous oxidative damage is a major factor in aging and the degenerative diseases associated with aging, such as cancer, heart disease, brain deterioration, and cataracts. They discuss the role of various antioxidants in preventing cancer and the degenerative diseases of aging. They also discuss why mitogenesis is critical for mutagenesis and why agents increasing either mitogenesis or mutagenesis are expected to be carcinogens. The known and likely causes of cancer are discussed, as well as the contributions of epidemiology and the testing of chemicals in animals to the understanding of causes of cancer in humans

  4. Basic Wiring.

    Science.gov (United States)

    Kaltwasser, Stan; And Others

    This module is the first in a series of three wiring publications; it serves as the foundation for students enrolled in a wiring program. It is a prerequisite to either "Residential Wiring" or "Commercial and Industrial Wiring." The module contains 16 instructional units that cover the following topics: occupational…

  5. Aging-caused changes in optical anisotropy of fibrous tissues

    Science.gov (United States)

    Mikhailova, Alyona D.; Ermolenko, Sergey B.; Zimnyakov, Dmitry A.; Angelsky, Oleg V.

    2009-10-01

    Energy density approach as a modification of the coherent potential approximation was applied to analyze the influence of aging-caused changes in the fibrous tissue on its birefringence. The real fibrous tissue such as tendon was modeled by disordered array of partially oriented dielectric cylinders illuminated by a normally incident linearly polarized plane wave. The supraspinatus human tendon was taken as an object for theoretical modeling. The morphological features of the studied tissue were considered for a system of collagen fiber bundles embedded in a carbohydrate matrix. The latter one is a mixture of glycosaminoglycans and proteoglycans. Age-caused changes of the fibers and matrix influence on the spectral dependence of optical anisotropy spectrum.

  6. Ageing management program of wires for Atucha II Nuclear Power Plant

    International Nuclear Information System (INIS)

    Zorrilla, J.; Antonaccio, E.; Luraschi, C.; Simionato, E.; Nieto, H.

    2012-01-01

    Electrical cables constitute one of the most important components of NPP in terms o maintenance, safety and availability of the plant. Due to their large extension (thousands of kilometers) it is impossible to fully replace them and aging management becomes essential for long term operation of NPP. Since Atucha II is under construction there was a good opportunity to establish and implement a holistic cable aging management program from the beginning according to the state of the art in this field. The scope of this program involves safety related cables, including EQ cables and non EQ cables as well. Due to the diversity of the installed cables is impossible to address an aging management program of every single specimen. However it is possible to establish 'cables families' of similar aging behavior based on insulation and jacket material, manufacture, etc Several aging management strategies were set for the different 'cables families'. These strategies include cables deposit in plant, elaboration of procedures of visual and tactile inspection, NDE techniques, etc Currently the aging management program is being implemented covering topic such as: Cable screening and grouping. Review of EQ documentation and conventional qualification information referring to the installed cables. Establishment of base line of condition monitoring techniques. Calibration and set up of test parameters for NDE techniques. Aging mechanism characterization and determination of. Design construction and installation of cable deposit in plant (author)

  7. Single Wire Detector Performance Over One Year of Operation

    CERN Document Server

    Hervas Aguilar, David Alberto

    2014-01-01

    Abstract When ionizing radiation passes through gas chambers in single wire detectors gas molecules separate into ions and electrons. By applying a strong localized electric field near the single wire an avalanche of electrons is created and it can be collected. The current produced in the wire is then proportional to the energy of the particle detected. Nevertheless, many factors can contribute to detector aging effects which are visible in a loss of gain caused by deposition of contaminants on the collecting wire. This study consists on novel data analysis techniques used to process large amounts of data produced by two simultaneously running single wire detectors. Aging effects are analyzed while environmental fluctuations are corrected for. A series of scripts carry out data filtering, data matching, corrections, and finally trend plotting by using ROOT’s extensive libraries developed at CERN.

  8. Wire Chamber

    CERN Multimedia

    Magnetoscriptive readout wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  9. Wire chamber

    CERN Multimedia

    1967-01-01

    Magnetoscriptive readout wire chamber.Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  10. wire chamber

    CERN Multimedia

    Proportional multi-wire chamber. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle. Proportional wire chambers allow a much quicker reading than the optical or magnetoscriptive readout wire chambers.

  11. wire chamber

    CERN Multimedia

    Was used in ISR (Intersecting Storage Ring) split field magnet experiment. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  12. Wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. wire chamber

    CERN Multimedia

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  14. wire chamber

    CERN Multimedia

    1985-01-01

    Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  15. Electromagnetic Nondestructive Evaluation of Wire Insulation and Models of Insulation Material Properties

    Science.gov (United States)

    Bowler, Nicola; Kessler, Michael R.; Li, Li; Hondred, Peter R.; Chen, Tianming

    2012-01-01

    Polymers have been widely used as wiring electrical insulation materials in space/air-craft. The dielectric properties of insulation polymers can change over time, however, due to various aging processes such as exposure to heat, humidity and mechanical stress. Therefore, the study of polymers used in electrical insulation of wiring is important to the aerospace industry due to potential loss of life and aircraft in the event of an electrical fire caused by breakdown of wiring insulation. Part of this research is focused on studying the mechanisms of various environmental aging process of the polymers used in electrical wiring insulation and the ways in which their dielectric properties change as the material is subject to the aging processes. The other part of the project is to determine the feasibility of a new capacitive nondestructive testing method to indicate degradation in the wiring insulation, by measuring its permittivity.

  16. Causes, consequences, and reversal of immune system aging.

    Science.gov (United States)

    Montecino-Rodriguez, Encarnacion; Berent-Maoz, Beata; Dorshkind, Kenneth

    2013-03-01

    The effects of aging on the immune system are manifest at multiple levels that include reduced production of B and T cells in bone marrow and thymus and diminished function of mature lymphocytes in secondary lymphoid tissues. As a result, elderly individuals do not respond to immune challenge as robustly as the young. An important goal of aging research is to define the cellular changes that occur in the immune system and the molecular events that underlie them. Considerable progress has been made in this regard, and this information has provided the rationale for clinical trials to rejuvenate the aging immune system.

  17. Aboveground net primary production decline with stand age: potential causes.

    Science.gov (United States)

    Gower, S T; McMurtrie, R E; Murty, D

    1996-09-01

    Aboveground net primary production (ANPP) commonly reaches a maximum in young forest stands and decreases by 0-76% as stands mature. However, the mechanism(s) responsible for the decline are not well understood. Current hypotheses for declining ANPP with stand age include: (1) an altered balance between photosynthetic and respiring tissues, (2) decreasing soil nutrient availability, and (3) increasing stomatal limitation leading to reduced photosynthetic rates. Recent empirical and modeling studies reveal that mechanisms (2) and (3) are largely responsible for age-related decline in ANPP for forests in cold environments. Increasing respiratory costs appear to be relatively unimportant in explaining declining productivity in ageing stands.

  18. Structural brain changes in aging: courses, causes and cognitive consequences.

    Science.gov (United States)

    Fjell, Anders M; Walhovd, Kristine B

    2010-01-01

    The structure of the brain is constantly changing from birth throughout the lifetime, meaning that normal aging, free from dementia, is associated with structural brain changes. This paper reviews recent evidence from magnetic resonance imaging (MRI) studies about age-related changes in the brain. The main conclusions are that (1) the brain shrinks in volume and the ventricular system expands in healthy aging. However, the pattern of changes is highly heterogeneous, with the largest changes seen in the frontal and temporal cortex, and in the putamen, thalamus, and accumbens. With modern approaches to analysis of MRI data, changes in cortical thickness and subcortical volume can be tracked over periods as short as one year, with annual reductions of between 0.5% and 1.0% in most brain areas. (2) The volumetric brain reductions in healthy aging are likely only to a minor extent related to neuronal loss. Rather, shrinkage of neurons, reductions of synaptic spines, and lower numbers of synapses probably account for the reductions in grey matter. In addition, the length of myelinated axons is greatly reduced, up to almost 50%. (3) Reductions in specific cognitive abilities--for instance processing speed, executive functions, and episodic memory--are seen in healthy aging. Such reductions are to a substantial degree mediated by neuroanatomical changes, meaning that between 25% and 100% of the differences between young and old participants in selected cognitive functions can be explained by group differences in structural brain characteristics.

  19. Hsp72, inflammation, and aging: causes, consequences, and perspectives.

    Science.gov (United States)

    Ortega, Eduardo; Bote, María Elena; Besedovsky, Hugo Oscar; del Rey, Adriana

    2012-07-01

    Although aging is an inexorable component of life, its progress depends on how cumulative disruptions of homeostasis are compensated. Cumulative oxidative and inflammatory processes must be controlled to maintain successful aging. Heat shock proteins, such as those of the Hsp70 family, can be considered a danger signal, and their effects can either support longevity by neutralizing danger or can become detrimental when their production is not balanced. Here, we discuss evidence indicating that these highly conserved proteins can favor longevity when such balance is achieved. We emphasize mechanisms affected by Hsp72 that can interfere with effects of excessive oxidative stress and subtle inflammation and, acting either directly or by affecting neuro-immune-endocrine interactions, can mediate metabolic, neuroprotective, and behavioral adjustments during the aging process. © 2012 New York Academy of Sciences.

  20. Suspensions of Carbon Black in Polybutadiene: Causes of Thermal Aging.

    Science.gov (United States)

    von Meerwall, E.; Massey, J. C.; Mahmood, N.; Hong, M. P.; Kelley, F. N.

    1999-04-01

    Hydroxyl-terminated polybutadiene containing carbon black is used as liner in solid rocket motors, chemically cured after application. To study its undesirable pre-cure viscosity decrease with thermal aging at 60^oC we varied preparation and measurement conditions and measured weight loss, settling (centrifuging), NMR relaxation and diffusion, electrical volume resistivity, black aggregate structure (microscopy), and used surface-active agents. Viscosity in black-filled specimens depends on shear rate (shear thinning) and strongly on black concentration. Polymer molecular mobility and bulk electrical resistivity depend only weakly on aging, and no change in black aggregate structure is found. But preventing the evaporation of volatile components eliminates the slow viscosity reduction to a lower asymptote. This 60^oC aging behavior is seen in measurements made at 60^oC but not at 25^oC, an effect not well understood. Viscosity thermal aging is thought to be related to emulsification of the polymer by water adsorbed on black particle surfaces, mediated by other volatile or reactive molecular species.

  1. Aging effects in wire chambers operated at low pressure with TMAE and its effect on the use of BaF2-TMAE calorimetry at the SSC [Superconducting Super Collider

    International Nuclear Information System (INIS)

    Woody, C.L.

    1988-01-01

    This note summarizes the result of a study carried out on the aging effects in low pressure wire multiwire proportional chambers operated with gas mixtures containing TMAE. The purpose of the study was to investigate the effects of radiation damage in low pressure wire chambers used as a part of a BaF 2 -TMAE calorimeter operated at high rates for an extended period of time. 8 refs., 6 figs

  2. Effects of Intraoral Ageing on Ultimate Tensile Strength and Surface Topography of Superelastic NiTi Wires from Two Different Manufacturers: A Comparative in vivo Study

    Directory of Open Access Journals (Sweden)

    A Pravin Devaprasad

    2012-01-01

    Conclusion: Super elastic NiTi wires from 3M Unitek were found to be superior to the wires from American orthodontics in as received condition, after 3 months of clinical use and 6 months of clinical use. The surface topography of 3M Unitek wires was found to have less pitting and indentations than American orthodontic wires of comparable use. Wires from both manufactures were found to undergo degradation after clinical use. During the study, it was found that 3M Unitek NiTi superelastic wires had better ultimate tensile strength and surface topography than superelastic NiTi from American orthodontics.

  3. Plasma chemistry in wire chambers

    International Nuclear Information System (INIS)

    Wise, J.

    1990-05-01

    The phenomenology of wire chamber aging is discussed and fundamentals of proportional counters are presented. Free-radical polymerization and plasma polymerization are discussed. The chemistry of wire aging is reviewed. Similarities between wire chamber plasma (>1 atm dc-discharge) and low-pressure rf-discharge plasmas, which have been more widely studied, are suggested. Construction and use of a system to allow study of the plasma reactions occurring in wire chambers is reported. A proportional tube irradiated by an 55 Fe source is used as a model wire chamber. Condensable species in the proportional tube effluent are concentrated in a cryotrap and analyzed by gas chromatography/mass spectrometry. Several different wire chamber gases (methane, argon/methane, ethane, argon/ethane, propane, argon/isobutane) are tested and their reaction products qualitatively identified. For all gases tested except those containing methane, use of hygroscopic filters to remove trace water and oxygen contaminants from the gas resulted in an increase in the average molecular weight of the products, consistent with results from low-pressure rf-discharge plasmas. It is suggested that because water and oxygen inhibit polymer growth in the gas phase that they may also reduce polymer deposition in proportional tubes and therefore retard wire aging processes. Mechanistic implications of the plasma reactions of hydrocarbons with oxygen are suggested. Unresolved issues in this work and proposals for further study are discussed

  4. Causes medicales d'hospitalisation des personnes agees de 65 ans ...

    African Journals Online (AJOL)

    Les affections cerebro-cardiovasculaires, le diabete, le cancer et la demence augmentent avec l'age selon lfOMS. But : Faire lfinventaire des causes medicales dfhospitalisation des personnes agees (. 65 ans) et comparer ces causes a celles des adultes de 40 a 64 ans. Methodologie : Il s'agit d'une etude retrospective ...

  5. Wire chamber gases

    International Nuclear Information System (INIS)

    Va'vra, J.

    1992-04-01

    In this paper, we describe new developments in gas mixtures which have occurred during the last 3--4 years. In particular, we discuss new results on the measurement and modeling of electron drift parameters, the modeling of drift chamber resolution, measurements of primary ionization and the choice of gas for applications such as tracking, single electron detection, X-ray detection and visual imaging. In addition, new results are presented on photon feedback, breakdown and wire aging

  6. Study of tungsten filament aging in hot-wire chemical vapor deposition with silacyclobutane as a source gas and the H2 etching effect

    Science.gov (United States)

    Tong, Ling; Sveen, Chris E.; Shi, Yujun

    2008-06-01

    The tungsten filament aging when using silacyclobutane (SCB) as a source gas in a hot-wire chemical vapor deposition reactor was systematically studied by the characterization of surface morphology using scanning electron microscopy and the chemical composition analysis of the filament surfaces using Auger electron spectroscopy. It is shown that filament aging involves the formation of silicides and under more severe conditions, a pure silicon deposit. At low pressures of SCB samples, e.g., 0.06 and 0.03Torr, only Si3W5 alloy was formed. Silicon-rich silicide, Si2W, was found when using a higher pressure of SCB at 0.12Torr. At the high SCB pressure of 0.12Torr and low temperatures, pure silicon was deposited on the W filament surface. It is also demonstrated that H2 can etch the aged filament at high temperatures above 1900°C. The etching products detected by the 10.5eV vacuum ultraviolet laser single photon ionization/time-of-flight mass spectrometer include SiH4, SiCHx (x =2-5), and SiC2Hy (y =4-7).

  7. Minimisation of the wire position uncertainties of the new CERN vacuum wire scanner

    CERN Document Server

    AUTHOR|(CDS)2069346; Barjau Condomines, A

    In the next years the luminosity of the LHC will be significantly increased. This will require a much higher accuracy of beam profile measurement than actually achievable by the current wire scanner. The new fast wire scanner is foreseen to measure small emittance beams throughout the LHC injector chain, which demands a wire travelling speed up to 20 ms-1 and position measurement accuracy of the order of a few microns. The vibrations of the mechanical parts of the system, and particularly the vibrations of the thin carbon wire, were identified as the major error sources of wire position uncertainty. Therefore the understanding of the wire vibrations is a high priority for the design and operation of the new device. This document presents the work performed to understand the main causes of the wire vibrations observed in one of the existing wire scanner and the new proposed design.

  8. Noncontextual Wirings

    Science.gov (United States)

    Amaral, Barbara; Cabello, Adán; Cunha, Marcelo Terra; Aolita, Leandro

    2018-03-01

    Contextuality is a fundamental feature of quantum theory necessary for certain models of quantum computation and communication. Serious steps have therefore been taken towards a formal framework for contextuality as an operational resource. However, the main ingredient of a resource theory—a concrete, explicit form of free operations of contextuality—was still missing. Here we provide such a component by introducing noncontextual wirings: a class of contextuality-free operations with a clear operational interpretation and a friendly parametrization. We characterize them completely for general black-box measurement devices with arbitrarily many inputs and outputs. As applications, we show that the relative entropy of contextuality is a contextuality monotone and that maximally contextual boxes that serve as contextuality bits exist for a broad class of scenarios. Our results complete a unified resource-theoretic framework for contextuality and Bell nonlocality.

  9. Assessment of Oro-Maxillofacial Trauma According to Gender, Age, Cause and Type of the Injury.

    Science.gov (United States)

    Siber, Stjepan; Matijević, Marko; Sikora, Miroslav; Leović, Dinko; Mumlek, Ivan; Macan, Darko

    2015-12-01

    The occurrence and causes of maxillofacial trauma varies in different regions of the world. The aim of this study was to identify the occurrence, types and causes of maxillofacial injuries according to the age and gender differences in patients treated at the Department of Maxillofacial Surgery, University Hospital Center Osijek, between January 2011 and December 2013. A total of 64 patients, 41 males (64.1%) and 23 females (35.9%), aged from 18 to 86 years (mean age 42) participated in the study. Data collected and analyzed included gender, age, cause of injury and the type of maxillofacial injuries. The most common cause of injuries in both gender groups was falling down (39% males; 65% females). The second leading cause of injuries in males was interpersonal violence (29%) and in females traffic accident (26%) (p0.05). The most common causes of injuries in the youngest patients was violence (43%), and in others fall (50-70%; p0.05). The majority of the falls and violence caused bone tissue injuries, and soft tissue and dentalveolar injuries were detected in traffic and sports accidents (p>0.05). Falling down was the most common cause of oro-maxillofacial injuries in both men and women and in all three age groups. The leading type of injury was bone injury. The data obtained from this study provide important information for future prevention from injuries.

  10. Time series analysis of air pollution and mortality: effects by cause, age and socioeconomic status

    OpenAIRE

    Gouveia, N.; Fletcher, T.

    2000-01-01

    OBJECTIVE—To investigate the association between outdoor air pollution and mortality in São Paulo, Brazil.
DESIGN—Time series study
METHODS—All causes, respiratory and cardiovascular mortality were analysed and the role of age and socioeconomic status in modifying associations between mortality and air pollution were investigated. Models used Poisson regression and included terms for temporal patterns, meteorology, and autocorrelation.
MAIN RESULTS—All causes all ages mortality showed much sm...

  11. Vibrating wire for beam profile scanning

    Directory of Open Access Journals (Sweden)

    S. G. Arutunian

    1999-12-01

    Full Text Available A method that measures the transverse profile (emittance of the bunch by detecting radiation arising at the scattering of the bunch on scanning wire is widely used. In this work information about bunch scattering is obtained by measuring the oscillation frequency of the tightened scanning wire. In such a way, the system of radiation (or secondary particles extraction and measurement can be removed. The entire unit consists of a compact fork with tightened wire and a scanning system. Normal oscillation frequency of a wire depends on wire tension, its geometric parameters, and, in a second approximation, its elastic characteristics. Normal oscillations are generated by interaction of an alternating current through the wire with magnetic field of a permanent magnet. In this case, it is suggested that the magnetic field of the accelerator (field of dipole magnets or quadrupole magnets be used for excitation of oscillations. The dependence of oscillation frequency on beam scattering is determined by several factors, including changes of wire tension caused by transverse force of the beam and influence of beam self-field. Preliminary calculations show that the influence of wire heating will dominate. We have studied strain gauges on the basis of vibrating wire from various materials (tungsten, beryl bronze, and niobium zirconium alloys. A scheme of normal oscillation generation by alternating current in autogeneration circuit with automatic frequency adjustment was selected. A special method of wire fixation and elimination of transverse degrees of freedom allows us to achieve relative stability better than 10^{-5} during several days at a relative resolution of 10^{-6}. Experimental results and estimates of wire heating of existing scanners show that the wire heats up to a few hundred grades, which is enough for measurements. The usage of wire of micrometer thickness diminishes the problem of wire thermalization speed during the scanning of the bunch.

  12. An experimental test of the causes of forest growth decline with stand age.

    Science.gov (United States)

    Michael G. Ryan; Dan Binkley; James H. Fownes; Christian Giardina; Randy S. Senock

    2004-01-01

    The decline in aboveground wood production after canopy closure in even-aged forest stands is a common pattern in forests, but clear evidence for the mechanism causing the decline is lacking. The problem is fundamental to forest biology, commercial forestry (the decline sets the rotation age), and to carbon storage in forests. We tested three hypotheses...

  13. Alterations and diseases of the gastrointestinal tract caused by old age

    International Nuclear Information System (INIS)

    Bayerl, F.

    1981-01-01

    The dissertation reviews the publications on 'The gastrointestinal tract in old age' since 1941. As in the 1941 publication by Heinrich, particular interest is taken in diagnostic radiology. The lower age limit of the cases described was set at 55 to 60 years. Oesophageal changes ranged from functional disturbances (e.g. atonia, changes in peristalsis, or dilatation) to chronic inflammation, displacement caused by the surrounding organs, and tumours (mainly carcinoma). Formation of diverticula takes an intermediate position. Of the gastric and duodenal changes, hiatal hermia and chronic atrophic gastritis were the most frequent. Ulcers caused by old age differ from 'common' ulcers in some respects, and the symptoms may be confused with those of gastric carcinoma. Early gastric carcinoma is another disease whose incidence increases with age. Thoracic and spinal changes may cause impressions on the stomach. The effects of old age on the time of passage of contrast media, on gastric tone, and on the shape of the stomach remain unclear. Changes caused by old age in the small and large intestine range from formation of diverticula and vascular diseases (e.g. ischaemic colitis and obstruction of the mesenteric vessels) to the frequent carcinoma of the large intestine and rectum. According to this study it has to be supposed that the degenerative atrophic processes of aging and previous diseases occurring increasingly in old age, favour the provocation of ratrogenic injuries. (orig./MG) [de

  14. Answering the ultimate question "what is the proximal cause of aging?".

    Science.gov (United States)

    Blagosklonny, Mikhail V

    2012-12-01

    Recent discoveries suggest that aging is neither driven by accumulation of molecular damage of any cause, nor by random damage of any kind. Some predictions of a new theory, quasi-programmed hyperfunction, have already been confirmed and a clinically-available drug slows aging and delays diseases in animals. The relationship between diseases and aging becomes easily apparent. Yet, the essence of aging turns out to be so startling that the theory cannot be instantly accepted and any possible arguments are raised for its disposal. I discuss that these arguments actually support a new theory. Are any questions remaining? And might accumulation of molecular damage still play a peculiar role in aging?

  15. Age-related differences in mechanism, cause, and location of trauma deaths

    DEFF Research Database (Denmark)

    Meisler, Rikke; Thomsen, Annemarie Bondegaard; Theilade, Peter

    2011-01-01

    ages, but the trauma mechanism differed among ages, with falls constituting 46.8% of trauma deaths in the elderly. The primary cause of death was head and spine injuries across all age-groups. Death took place before arrival at the hospital in 45% of the cases, but death during primary admission became...... regarding the trauma type, mechanism, cause and location of death. RESULTS: A total of 2923 patients were registered, of which 292 (9.9%) died within 30 days. Mortality increased with age, with a mortality of 46.1% in patients older than 80 years old. Blunt trauma was the most frequent trauma type at all...... increasingly important with advanced age. CONCLUSION: Increasing age was associated with higher mortality, an increased proportion of falls and fatal head or spine injuries....

  16. Effects of Intraoral Ageing on Ultimate Tensile Strength and Surface Topography of Superelastic NiTi Wires from Two Different Manufacturers: A Comparative in vivo Study

    OpenAIRE

    A Pravin Devaprasad; T R Chandrasekaran

    2012-01-01

    Aim : The purpose of this study was to evaluate and compare the ultimate tensile strength/fracture resistance of superelastic NiTi wires from two manufacturers 3M Unitek and American orthodontics in as received condition, after 3 months and 6 months of intraoral use. The wires would also be evaluated for surface characteristics under a scanning electron microscope. Materials and methods: Superelastic NiTi wires of 0.016" from 3M Unitek were categorized as group I and from American orthodon...

  17. Stretched Wire Mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Bowden, Gordon; /SLAC

    2005-09-06

    Stretched wires are beginning to play an important role in the alignment of accelerators and synchrotron light sources. Stretched wires are proposed for the alignment of the 130 meter long LCLS undulator. Wire position technology has reached sub-micron resolution yet analyses of perturbations to wire straightness are hard to find. This paper considers possible deviations of stretched wire from the simple 2-dimensional catenary form.

  18. Combined effects of different heat treatments and Cu element on transformation behavior of NiTi orthodontic wires.

    Science.gov (United States)

    Seyyed Aghamiri, S M; Ahmadabadi, M Nili; Raygan, Sh

    2011-04-01

    The shape memory nickel-titanium alloy has been applied in many fields due to its unique thermal and mechanical performance. One of the successful applications of NiTi wires is in orthodontics because of its good characteristics such as low stiffness, high spring back, high stored energy, biocompatibility, superelasticity and shape memory effect. The mechanical properties of wires are paid special attention which results in achieving continuous optimal forces and eventually causing rapid tooth movement without any damage. The behavior of the alloy can be controlled by chemical composition and thermo-mechanical treatment during the manufacturing process. In this study two kinds of commercial superelastic NiTi archwires of 0.41 mm diameter were investigated: Copper NiTi and Highland Metal. The chemical analysis of both wires was estimated by energy dispersive spectroscopy (EDS). It was showed that Copper NiTi wire contained copper and chromium. The two types of wires were exposed to different heat treatment conditions at 400 and 500 °C for 10 and 60 min to compare the behavior of the wires at aged and as-received conditions. Phase transformation temperatures clarified by differential scanning calorimetry (DSC) showed B2 R B19 transformation in Highland Metal wire and B2 B19(') transformation in Copper NiTi wire. Three point bending (TPB) tests in the certain designed fixture were performed at 37 °C to evaluate the mechanical behavior of the wires. The experimental results revealed the superelastic behavior of the Highland Metal wire after 60 min ageing at 400 and 500 °C and the plastic deformation of the Copper NiTi wire after annealing due to the effect of copper in the alloy composition. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Wired at a young age: the effect of caffeine and technology on sleep duration and body mass index in school-aged children.

    Science.gov (United States)

    Calamaro, Christina J; Yang, Kyeongra; Ratcliffe, Sarah; Chasens, Eileen R

    2012-01-01

    Two problems affecting school-aged children in the United States are inadequate sleep and an increased prevalence of obesity. The purpose of this study was to quantify media-related technology use and caffeine consumption in order to assess their potential effects on sleep duration and body mass index (BMI) in children. The study was a secondary analysis of children 6 to 10 years of age (N = 625) from the National Sleep Foundation's Sleep in America Poll. Regression analysis was used to assess the relationship between caffeine and technology use, sleep variables, and BMI, adjusting for age, race, gender, and general health. Almost 30% (29.5%) of the children consumed a daily caffeinated beverage, and 42.4% had a television in the bedroom. Children who drank caffeinated beverages had 15 fewer minutes of sleep per night than did children who did not drink such beverages (b = -0.27, p = .002). Children with three technology items in their bedroom received 45 fewer minutes of sleep than did children without these items in their bedroom (b = -0.75, p = .010). Having adjusted for variables, only drinking caffeinated beverages was associated with a BMI z score. The complex relationships between caffeine intake and the use of technology with shortened periods of sleep and increased BMI need further study. Future research should explore how these risk factors for shortened periods of sleep can be modified in this young population. Copyright © 2012. Published by Mosby, Inc.

  20. A Vibrating Wire System For Quadrupole Fiducialization

    Energy Technology Data Exchange (ETDEWEB)

    Wolf, Zachary

    2010-12-13

    A vibrating wire system is being developed to fiducialize the quadrupoles between undulator segments in the LCLS. This note provides a detailed analysis of the system. The LCLS will have quadrupoles between the undulator segments to keep the electron beam focused. If the quadrupoles are not centered on the beam axis, the beam will receive transverse kicks, causing it to deviate from the undulator axis. Beam based alignment will be used to move the quadrupoles onto a straight line, but an initial, conventional alignment must place the quadrupole centers on a straight line to 100 {micro}m. In the fiducialization step of the initial alignment, the position of the center of the quadrupole is measured relative to tooling balls on the outside of the quadrupole. The alignment crews then use the tooling balls to place the magnet in the tunnel. The required error on the location of the quadrupole center relative to the tooling balls must be less than 25 {micro}m. In this note, we analyze a system under construction for the quadrupole fiducialization. The system uses the vibrating wire technique to position a wire onto the quadrupole magnetic axis. The wire position is then related to tooling balls using wire position detectors. The tooling balls on the wire position detectors are finally related to tooling balls on the quadrupole to perform the fiducialization. The total 25 {micro}m fiducialization error must be divided between these three steps. The wire must be positioned onto the quadrupole magnetic axis to within 10 {micro}m, the wire position must be measured relative to tooling balls on the wire position detectors to within 15 {micro}m, and tooling balls on the wire position detectors must be related to tooling balls on the quadrupole to within 10 {micro}m. The techniques used in these three steps will be discussed. The note begins by discussing various quadrupole fiducialization techniques used in the past and discusses why the vibrating wire technique is our method

  1. A STUDY ON PREVALENCE AND CAUSES OF CORNEAL BLINDNESS IN PAEDIATRIC AGE GROUP

    Directory of Open Access Journals (Sweden)

    E. Ramadevi

    2017-12-01

    Full Text Available BACKGROUND Corneal disease is responsible for less than 2% of blindness in children in industrialised countries. In poor countries of the world, corneal scarring occurs due to vitamin A deficiency, measles and ophthalmia neonatorum. Thus, corneal disease is an important cause of blindness among children living in developing nations, which already carry a major burden of blindness. The aim of the study is to study the1. Prevalence of corneal blindness in the paediatric age group. 2. Causes of corneal blindness in the paediatric age group. 3. Morbidity of corneal blindness in the paediatric age group. MATERIALS AND METHODS It was cross-sectional observational study. Study Period- December 2014 to August 2016. Study Done- Government General Hospital, Kakinada. Sample Size- 50 patients. Inclusion Criteria- Children of age group 6 to 12 years with corneal blindness who have attended the outpatient department during the study period. Exclusion Criteria- Children with childhood blindness other than corneal pathology. Study Tools- Predesigned, semi-structured questionnaire regarding age, sex and age of onset of visual loss, laterality, history of ocular injury, vitamin A immunisation, family history of consanguinity and place of residence and socioeconomic status was taken. Visual acuity was measured using an E optotype and Landolt broken C chart with best corrected vision. Visual loss was classified according to the WHO categories of visual impairment. Ophthalmic examination was done by slit lamp and B scan. RESULTS Ocular trauma and corneal ulcers are most common cause of corneal blindness. 84% of corneal blindness cases were preventable and curable. CONCLUSION Trauma was the commonest cause of corneal blindness followed by infectious keratitis. 84% of corneal blindness was preventable and curable. Most causes of corneal blindness were avoidable.

  2. submitter Dynamical Models of a Wire Scanner

    CERN Document Server

    Barjau, Ana; Dehning, Bernd

    2016-01-01

    The accuracy of the beam profile measurements achievable by the current wire scanners at CERN is limited by the vibrations of their mechanical parts. In particular, the vibrations of the carbon wire represent the major source of wire position uncertainty which limits the beam profile measurement accuracy. In the coming years, due to the Large Hadron Collider (LHC) luminosity upgrade, a wire traveling speed up to 20 $m s^{−1}$ and a position measurement accuracy of the order of 1 μm will be required. A new wire scanner design based on the understanding of the wire vibration origin is therefore needed. We present the models developed to understand the main causes of the wire vibrations observed in an existing wire scanner. The development and tuning of those models are based on measurements and tests performed on that CERN proton synchrotron (PS) scanner. The final model for the (wire + fork) system has six degrees-of-freedom (DOF). The wire equations contain three different excitation terms: inertia...

  3. Ethnic inequalities in age- and cause-specific mortality in The Netherlands

    NARCIS (Netherlands)

    Bos, Vivian; Kunst, Anton E.; Keij-Deerenberg, Ingeborg M.; Garssen, Joop; Mackenbach, Johan P.

    2004-01-01

    BACKGROUND: By describing ethnic differences in age- and cause-specific mortality in The Netherlands we aim to identify factors that determine whether ethnic minority groups have higher or lower mortality than the native population of the host country. METHODS: We used data for 1995-2000 from the

  4. DNA Methylation and All-Cause Mortality in Middle-Aged and Elderly Danish Twins

    DEFF Research Database (Denmark)

    Svane, Anne Marie; Soerensen, Mette; Lund, Jesper

    2018-01-01

    Several studies have linked DNA methylation at individual CpG sites to aging and various diseases. Recent studies have also identified single CpGs whose methylation levels are associated with all-cause mortality. In this study, we perform an epigenome-wide study of the association between CpG met...

  5. Answering the ultimate question “What is the Proximal Cause of Aging?”

    Science.gov (United States)

    Blagosklonny, Mikhail V.

    2012-01-01

    Recent discoveries suggest that aging is neither driven by accumulation of molecular damage of any cause, nor by random damage of any kind. Some predictions of a new theory, quasi-programmed hyperfunction, have already been confirmed and a clinically-available drug slows aging and delays diseases in animals. The relationship between diseases and aging becomes easily apparent. Yet, the essence of aging turns out to be so startling that the theory cannot be instantly accepted and any possible arguments are raised for its disposal. I discuss that these arguments actually support a new theory. Are any questions remaining? And might accumulation of molecular damage still play a peculiar role in aging? PMID:23425777

  6. Wire bonding in microelectronics

    CERN Document Server

    Harman, George G

    2010-01-01

    Wire Bonding in Microelectronics, Third Edition, has been thoroughly revised to help you meet the challenges of today's small-scale and fine-pitch microelectronics. This authoritative guide covers every aspect of designing, manufacturing, and evaluating wire bonds engineered with cutting-edge techniques. In addition to gaining a full grasp of bonding technology, you'll learn how to create reliable bonds at exceedingly high yields, test wire bonds, solve common bonding problems, implement molecular cleaning methods, and much more. Coverage includes: Ultrasonic bonding systems and technologies, including high-frequency systems Bonding wire metallurgy and characteristics, including copper wire Wire bond testing Gold-aluminum intermetallic compounds and other interface reactions Gold and nickel-based bond pad plating materials and problems Cleaning to improve bondability and reliability Mechanical problems in wire bonding High-yield, fine-pitch, specialized-looping, soft-substrate, and extreme-temperature wire bo...

  7. Water Desalination with Wires

    NARCIS (Netherlands)

    Porada, S.; Sales, B.B.; Hamelers, H.V.M.; Biesheuvel, P.M.

    2012-01-01

    We show the significant potential of water desalination using a novel capacitive wire-based technology in which anode/cathode wire pairs are constructed from coating a thin porous carbon electrode layer on top of electrically conducting rods (or wires). By alternately dipping an array of electrode

  8. Investigation of wire motion in superconducting magnets

    International Nuclear Information System (INIS)

    Ogitsu, T.; Tsuchiya, K.; Devred, A.

    1990-09-01

    The large Lorentz forces occuring during the excitation of superconducting magnets can provoke sudden motions of wire, which eventually release enough energy to trigger a quench. These wire motions are accompanied by two electromagnetic effects: an induced emf along the moved wire, and a local change in flux caused by the minute dislocation of current. Both effects cause spikes in the coil voltage. Voltage data recorded during the excitation of a superconducting quadrupole magnet which early exhibit such events are here reported. Interpretations of the voltage spikes in terms of energy release are also presented, leading to insights on the spectrum of the disturbances which occur in real magnets. 15 refs

  9. Effectiveness of pulsed electromagnetic field for pain caused by placement of initial orthodontic wire in female orthodontic patients: A preliminary single-blind randomized clinical trial.

    Science.gov (United States)

    Jung, Jin-Gon; Park, Jae Hyun; Kim, Sang-Cheol; Kang, Kyung-Hwa; Cho, Jin-Hyoung; Cho, Jin-Woo; Chang, Na-Young; Bay, R Curtis; Chae, Jong-Moon

    2017-11-01

    The purpose of this 2-arm parallel trial was to assess the effects of pulsed electromagnetic field (PEMF) on the reduction of pain caused by initial orthodontic tooth movement. Thirty-three female patients (mean age, 16.8 ± 3.8 years) who began orthodontic treatment using fixed appliances were examined. In the pilot study, male patients were less likely to use the PEMF device (epatchQ; Speed Dental, Seoul, Korea) and answer a survey consistently, so eligibility criteria were female patients who were periodontally and systemically healthy at the initiation of treatment and had no history of dental pain in the prior 2 weeks or who used no medications (anti-inflammatory or analgesic drugs) during the experiment period. Each patient had brackets bonded on the maxillary teeth, and a 0.014-in nickel-titanium archwire was tied with elastomeric rings. Their maxillary arches were randomly divided into left and right sides in a split-mouth design: a normal PEMF device (experimental group) was used on 1 side, and a PEMF device with an inversely inserted battery (placebo group) was used on the opposite side of the arch for 7 hours on 3 consecutive nights. A Google survey link was sent to the patients' mobile phones via text message, and they were instructed to record their current pain on the survey. The survey was sent a total of 6 times after insertion of the initial archwire at 0 (T0), 2 (T1), 6 (T2), 24 (T3), 48 (T4), and 72 (T5) hours. Patients recorded the degree of pain in resting and clenching states using a numeric rating scale (NRS) from 1 (no pain) to 10 (worst pain). PEMF devices were used after T2. Generalized linear mixed models, along with ancillary pairwise analyses, were used to model and evaluate the differences in pain reported over 72 hours. The NRS scores did not differ across the groups during the before-PEMF phase for resting (mean difference, -0.07; 95% confidence interval [CI], -0.73 to 0.59; P = 0.842) and clenching (mean difference, -0

  10. Aging causes decreased resistance to multiple stresses and a failure to activate specific stress response pathways

    Science.gov (United States)

    Bergsma, Alexis L.; Senchuk, Megan M.; Van Raamsdonk, Jeremy M.

    2016-01-01

    In this work, we examine the relationship between stress resistance and aging. We find that resistance to multiple types of stress peaks during early adulthood and then declines with age. To dissect the underlying mechanisms, we use C. elegans transcriptional reporter strains that measure the activation of different stress responses including: the heat shock response, mitochondrial unfolded protein response, endoplasmic reticulum unfolded protein response, hypoxia response, SKN-1-mediated oxidative stress response, and the DAF-16-mediated stress response. We find that the decline in stress resistance with age is at least partially due to a decreased ability to activate protective mechanisms in response to stress. In contrast, we find that any baseline increase in stress caused by the advancing age is too mild to detectably upregulate any of the stress response pathways. Further exploration of how worms respond to stress with increasing age revealed that the ability to mount a hormetic response to heat stress is also lost with increasing age. Overall, this work demonstrates that resistance to all types of stress declines with age. Based on our data, we speculate that the decrease in stress resistance with advancing age results from a genetically-programmed inactivation of stress response pathways, not accumulation of damage. PMID:27053445

  11. Aging causes decreased resistance to multiple stresses and a failure to activate specific stress response pathways.

    Science.gov (United States)

    Dues, Dylan J; Andrews, Emily K; Schaar, Claire E; Bergsma, Alexis L; Senchuk, Megan M; Van Raamsdonk, Jeremy M

    2016-04-01

    In this work, we examine the relationship between stress resistance and aging. We find that resistance to multiple types of stress peaks during early adulthood and then declines with age. To dissect the underlying mechanisms, we use C. elegans transcriptional reporter strains that measure the activation of different stress responses including: the heat shock response, mitochondrial unfolded protein response, endoplasmic reticulum unfolded protein response, hypoxia response, SKN-1-mediated oxidative stress response, and the DAF-16-mediated stress response. We find that the decline in stress resistance with age is at least partially due to a decreased ability to activate protective mechanisms in response to stress. In contrast, we find that any baseline increase in stress caused by the advancing age is too mild to detectably upregulate any of the stress response pathways. Further exploration of how worms respond to stress with increasing age revealed that the ability to mount a hormetic response to heat stress is also lost with increasing age. Overall, this work demonstrates that resistance to all types of stress declines with age. Based on our data, we speculate that the decrease in stress resistance with advancing age results from a genetically-programmed inactivation of stress response pathways, not accumulation of damage.

  12. PS wire chamber

    CERN Document Server

    1970-01-01

    A wire chamber used at CERN's Proton Synchrotron accelerator in the 1970s. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  13. Aging causes collateral rarefaction and increased severity of ischemic injury in multiple tissues

    Science.gov (United States)

    Faber, James E.; Zhang, Hua; Lassance-Soares, Roberta M.; Prabhakar, Pranay; Najafi, Amir H.; Burnett, Mary Susan; Epstein, Stephen E.

    2011-01-01

    Objective Aging is a major risk factor for increased ischemic tissue injury. Whether collateral rarefaction and impaired remodeling contribute to this is unknown. We quantified the number and diameter of native collaterals, and their remodeling in 3-, 16-, 24-, and 31-months-old mice. Methods and Results Aging caused an “age-dose-dependent” greater drop in perfusion immediately after femoral artery ligation, followed by a diminished recovery of flow and increase in tissue injury. These effects were associated with a decline in collateral number, diameter and remodeling. Angiogenesis was also impaired. Mechanistically, these changes were not accompanied by reduced recruitment of T-cells or macrophages to remodeling collaterals. However, eNOS signaling was dysfunctional, as indicated by increased protein nitrosylation and less phosphorylated eNOS and VASP in collateral wall cells. The cerebral circulation exhibited a similar age-dose-dependent loss of collateral number and diameter and increased tortuosity, resulting in an increase in collateral resistance and infarct volume (e.g., 6- and 3-fold, respectively, in 24-months-old mice) after artery occlusion. This was not associated with rarefaction of similarly-sized arterioles. Collateral remodeling was also reduced. Conclusions Our findings demonstrate that aging causes rarefaction and insufficiency of the collateral circulation in multiple tissues, resulting in more severe ischemic tissue injury. PMID:21617137

  14. Guide Wire Entrapment during Central Venous Catheterization

    Directory of Open Access Journals (Sweden)

    Kyung Woo Kim

    2014-05-01

    Full Text Available We experienced a case of venous vessel wall entrapment between the introducer needle and the guide wire during an attempt to perform right internal jugular vein (IJV catheterization. The guide wire was introduced with no resistance but could not be withdrawn. We performed ultrasonography and C-arm fluoroscopy to confirm the entrapment location. We assumed the introducer needle penetrated the posterior vessel wall during the puncture and that only the guide wire entered the vein; an attempt to retract the wire pinched the vein wall between the needle tip and the guide wire. Careful examination with various diagnostic tools to determine the exact cause of entrapment is crucial for reducing catastrophic complications and achieving better outcomes during catheterization procedures.

  15. Wiring System Diagnostic Techniques for Legacy Aircraft

    Science.gov (United States)

    2003-02-01

    Reunions des specialistes des techniques de estion du cycle de vie pour vehicules aeriens vieillissants ] To order the complete compilation report, use...Ageing Mechanisms and Control. Specialists’ Meeting on Life Management Techniques for Ageing Air Vehicles [Les mecanismes vieillissants et le controle...be identified. Additionally, wiring failures tend to be intermittent in nature and can take considerable time to isolate. Wire modifications and

  16. Kirschner Wire Breakage during Removal Requiring Retrieval

    Directory of Open Access Journals (Sweden)

    Kai Yuen Wong

    2016-01-01

    Full Text Available Kirschner wires (K-wires are widely used for fixation of fractures and dislocations in the hand as they are readily available, reliable, and cost-effective. Complication rates of up to 18% have been reported. However, K-wire breakage during removal is rare. We present one such case illustrating a simple technique for retrieval. A 35-year-old male presented with a distal phalanx fracture of his right middle finger. This open fracture was treated with K-wire fixation. Postoperatively, he developed a pin site infection with associated finger swelling. The K-wire broke during removal with the proximal piece completely retained in his middle phalanx. To minimise risk of osteomyelitis, the K-wire was removed with a novel surgical technique. He had full return of hand function. Intraoperative K-wire breakage has a reported rate of 0.1%. In our case, there was no obvious cause of breakage and the patient denied postoperative trauma. On the other hand, pin site infections are much more common with reported rates of up to 7% in the hand or wrist. K-wire fixation is a simple method for bony stabilisation but can be a demanding procedure with complications often overlooked. It is important to be aware of the potential sequelae.

  17. Gender inequality in New Zealand life expectancy: decomposition by age and cause.

    Science.gov (United States)

    Sandiford, Peter

    2009-12-11

    AIM To quantify gender inequality in life expectancy at birth (LEB) in New Zealand and the contribution to it made by different age groups and causes of death. To examine the response of the health sector.METHOD Determination of the trend in sex differences in LEB. Multiple decrement decomposition of LEB differences into components ages and causes. Review of the gender equity policies and priorities of New Zealand's main health sector stakeholders.RESULTS A difference between the sexes in LEB of 4.7 years for Māori and 4.0 years for non-Māori, reverses the historically lower gender disparity among the Māori. Over half of the sex difference in LEB is accounted for by heart disease and all types of cancer and almost a quarter by accidents and suicide but male survival disadvantage is evident in many other causes of death. The health sector is beginning to acknowledge the survival disadvantage of men as inequitable, and reducing disparity as a legitimate goal for health policy.CONCLUSION Although gender inequality in LEB is declining among the non-Māori it remains high among the Māori. Smoking habits may explain some of the difference in LEB but policies must also address the causes of sex differences in accidental death and suicide.

  18. Cardiac myxoma: An uncommon cause of recurrent stroke in uncommon age

    Directory of Open Access Journals (Sweden)

    Harish Kumar

    2015-01-01

    Full Text Available Atrial fibrillation is the most common cause of cardiogenic emboli in stroke, responsible for over 50% cases of total stroke patients. Myxoma is responsible only in few cases. A stroke caused by left atrial myxoma commonly occur in young females. This patient presented with the repeated attack of stroke in the age of 80 years. However, it is the most common benign cardiac tumor found more frequently. In young adults with stroke or transient ischemic attack than in older patients. Age of the patient and unusual cause of recurrent stroke make this case report interesting. An 80-year-old male with no other conventional vascular risk factors such as hypertension, diabetes, or hyperlipidemia presented with left hemiparesis. Infarction over the right middle cerebral artery was disclosed on a magnetic resonance imaging study. The patient was a known case of right hemiparesis 3 years back, which was improved. The cause of repeated attack of stroke was left atrial myxoma, diagnosed by two-dimensional echocardiography.

  19. Causes, Consequences and Public Health Implications of Low B-Vitamin Status in Ageing

    Directory of Open Access Journals (Sweden)

    Kirsty Porter

    2016-11-01

    Full Text Available The potential protective roles of folate and the metabolically related B-vitamins (vitamins B12, B6 and riboflavin in diseases of ageing are of increasing research interest. The most common cause of folate and riboflavin deficiencies in older people is low dietary intake, whereas low B12 status is primarily associated with food-bound malabsorption, while sub-optimal vitamin B6 status is attributed to increased requirements in ageing. Observational evidence links low status of folate and the related B-vitamins (and/or elevated concentrations of homocysteine with a higher risk of degenerative diseases including cardiovascular disease (CVD, cognitive dysfunction and osteoporosis. Deficient or low status of these B-vitamins alone or in combination with genetic polymorphisms, including the common MTHFR 677 C → T polymorphism, could contribute to greater disease risk in ageing by causing perturbations in one carbon metabolism. Moreover, interventions with the relevant B-vitamins to optimise status may have beneficial effects in preventing degenerative diseases. The precise mechanisms are unknown but many have been proposed involving the role of folate and the related B-vitamins as co-factors for one-carbon transfer reactions, which are fundamental for DNA and RNA biosynthesis and the maintenance of methylation reactions. This review will examine the evidence linking folate and related B-vitamins with health and disease in ageing, associated mechanisms and public health implications.

  20. Early age conductive hearing loss causes audiogenic seizure and hyperacusis behavior.

    Science.gov (United States)

    Sun, Wei; Manohar, Senthilvelan; Jayaram, Aditi; Kumaraguru, Anand; Fu, Qiang; Li, Ji; Allman, Brian

    2011-12-01

    Recent clinical reports found a high incidence of recurrent otitis media in children suffering hyperacusis, a marked intolerance to an otherwise ordinary environmental sound. However, it is unclear whether the conductive hearing loss caused by otitis media in early age will affect sound tolerance later in life. Thus, we have tested the effects of tympanic membrane (TM) damage at an early age on sound perception development in rats. Two weeks after the TM perforation, more than 80% of the rats showed audiogenic seizure (AGS) when exposed to loud sound (120 dB SPL white noise, hearing loss recovered. The TM damaged rats also showed significantly enhanced acoustic startle responses compared to the rats without TM damage. These results suggest that early age conductive hearing loss may cause an impaired sound tolerance during development. In addition, the AGS can be suppressed by the treatment of vigabatrin, acute injections (250 mg/kg) or oral intakes (60 mg/kg/day for 7 days), an antiepileptic drug that inhibits the catabolism of GABA. c-Fos staining showed a strong staining in the inferior colliculus (IC) in the TM damaged rats, not in the control rats, after exposed to loud sound, indicating a hyper-excitability in the IC during AGS. These results indicate that early age conductive hearing loss can impair sound tolerance by reducing GABA inhibition in the IC, which may be related to hyperacusis seen in children with otitis media. Published by Elsevier B.V.

  1. Is cell aging caused by respiration-dependent injury to the mitochondrial genome

    Science.gov (United States)

    Fleming, J. E.; Yengoyan, L. S.; Miquel, J.; Cottrell, S. F.; Economos, A. C.

    1982-01-01

    Though intrinsic mitochondrial aging has been considered before as a possible cause of cellular senescence, the mechanisms of such mitochondrial aging have remained obscure. In this article, the hypothesis of free-radical-induced inhibition of mitochondrial replenishment in fixed postmitotic cells is expanded. It is maintained that the respiration-dependent production of superoxide and hydroxyl radicals may not be fully counteracted, leading to a continuous production of lipoperoxides and malonaldehyde in actively respiring mitochondria. These compounds, in turn, can easily react with the mitochondrial DNA which is in close spatial relationship with the inner mitochondrial membrane, producing an injury that the mitochondria may be unable to counteract because of their apparent lack of adequate repair mechanisms. Mitochondrial division may thus be inhibited leading to age-related reduction of mitochondrial numbers, a deficit in energy production with a concomitant decrease in protein synthesis, deterioration of physiological performance, and, therefore, of organismic performance.

  2. Mitochondrial polymerase gamma dysfunction and aging cause cardiac nuclear DNA methylation changes.

    Science.gov (United States)

    Koczor, Christopher A; Ludlow, Ivan; Fields, Earl; Jiao, Zhe; Ludaway, Tomika; Russ, Rodney; Lewis, William

    2016-04-01

    Cardiomyopathy (CM) is an intrinsic weakening of myocardium with contractile dysfunction and congestive heart failure (CHF). CHF has been postulated to result from decreased mitochondrial energy production and oxidative stress. Effects of decreased mitochondrial oxygen consumption also can accelerate with aging. We previously showed DNA methylation changes in human hearts with CM. This was associated with mitochondrial DNA depletion, being another molecular marker of CM. We examined the relationship between mitochondrial dysfunction and cardiac epigenetic DNA methylation changes in both young and old mice. We used genetically engineered C57Bl/6 mice transgenic for a cardiac-specific mutant of the mitochondrial polymerase-γ (termed Y955C). Y955C mice undergo left ventricular hypertrophy (LVH) at a young age (∼ 94 days old), and LVH decompensated to CHF at old age (∼ 255 days old). Results found 95 genes differentially expressed as a result of Y955C expression, while 4,452 genes were differentially expressed as a result of aging hearts. Moreover, cardiac DNA methylation patterns differed between Y955C (4,506 peaks with 68.5% hypomethylation) and aged hearts (73,286 peaks with 80.2% hypomethylated). Correlatively, of the 95 Y955C-dependent differentially expressed genes, 30 genes (31.6%) also displayed differential DNA methylation; in the 4,452 age-dependent differentially expressed genes, 342 genes (7.7%) displayed associated DNA methylation changes. Both Y955C and aging demonstrated significant enrichment of CACGTG-associated E-box motifs in differentially methylated regions. Cardiac mitochondrial polymerase dysfunction alters nuclear DNA methylation. Furthermore, aging causes a robust change in cardiac DNA methylation that is partially associated with mitochondrial polymerase dysfunction. Copyright © 2016 the American Physiological Society.

  3. Medial abrasion syndrome: a neglected cause of knee pain in middle and old age.

    Science.gov (United States)

    Lyu, Shaw-Ruey; Lee, Ching-Chih; Hsu, Chia-Chen

    2015-04-01

    Knee pain is a prevailing health problem of middle and old age. Medial plica-related medial abrasion syndrome (MAS), although a well-known cause of knee pain in younger individuals, has rarely been investigated in older individuals. This prospective study was conducted to investigate the prevalence and clinical manifestations of this syndrome as a cause of knee pain in middle and old age. The outcomes of arthroscopic treatment for this syndrome were also evaluated.A total of 232 knees of 169 patients >40 years of age (41-82, median: 63 years old) suffering from chronic knee pain were analyzed. The clinical diagnosis, predisposing factors, presenting symptoms, and physical signs were investigated. The sensitivity and specificity of each parameter of the clinical presentation for the diagnosis of MAS were evaluated after confirmation by arthroscopy. For patients with MAS, the roentgenographic and arthroscopic manifestations were investigated, and arthroscopic medial release (AMR) was performed. The outcomes were evaluated by the changes in the pain domain of the Knee Society scoring system and by patient satisfaction. The prevalence of medial plica was 95%, and osteoarthritis (OA) was the most common clinical diagnosis. Symptoms of pain and crepitus in motion and local tenderness during physical examination were the most sensitive parameters for the diagnosis. A history of a single knee injury combined with local tenderness and a palpable band found during physical examination were the most specific parameters for the diagnosis. The majority of patients suffering from this syndrome were successfully treated using AMR, yielding a satisfaction rate of 85.5% after a minimum of 3 years.MAS is a common cause of knee pain in middle and old age and can be effectively treated by AMR. Its concomitance with OA warrants further investigation.

  4. Uremia causes premature ageing of the T cell compartment in end-stage renal disease patients

    Directory of Open Access Journals (Sweden)

    Meijers Ruud WJ

    2012-09-01

    Full Text Available Abstract Background End-stage renal disease (ESRD patients treated with renal replacement therapy (RRT have premature immunologically aged T cells which may underlie uremia-associated immune dysfunction. The aim of this study was to investigate whether uremia was able to induce premature ageing of the T cell compartment. For this purpose, we examined the degree of premature immunological T cell ageing by examining the T cell differentiation status, thymic output via T cell receptor excision circle (TREC content and proliferative history via relative telomere length in ESRD patients not on RRT. Results Compared to healthy controls, these patients already had a lower TREC content and an increased T cell differentiation accompanied by shorter telomeres. RRT was able to enhance CD8+ T cell differentiation and to reduce CD8+ T cell telomere length in young dialysis patients. An increased differentiation status of memory CD4+ T cells was also noted in young dialysis patients. Conclusion Based on these results we can conclude that uremia already causes premature immunological ageing of the T cell system and RRT further increases immunological ageing of the CD8+ T cell compartment in particular in young ESRD patients.

  5. Problems associated with iridium-192 wire implants

    International Nuclear Information System (INIS)

    Arnott, S.J.; Law, J.; Ash, D.; Flynn, A.; Paine, C.H.; Durrant, K.R.; Barber, C.D.; Dixon-Brown, A.

    1985-01-01

    Three incidents are reported, from different radiotherapy centres, in which an implanted iridium-192 wire remained in the tissues of a patient after withdrawal of the plastic tubing in which it was contained. In each case the instrument used to cut the wire had probably formed a hook on the end of the wire which caused it to catch in the tissues. Detailed recommendations are made for avoiding such incidents in the future, the most important of which is that the patient should be effectively monitored after the supposed removal of all radioactive sources. (author)

  6. Conditional ablation of the choroideremia gene causes age-related changes in mouse retinal pigment epithelium.

    Directory of Open Access Journals (Sweden)

    Silène T Wavre-Shapton

    Full Text Available The retinal pigment epithelium (RPE is a pigmented monolayer of cells lying between the photoreceptors and a layer of fenestrated capillaries, the choriocapillaris. Choroideremia (CHM is an X-linked progressive degeneration of these three layers caused by the loss of function of Rab Escort protein-1 (REP1. REP1 is involved in the prenylation of Rab proteins, key regulators of membrane trafficking. To study the pathological consequences of chronic disruption of membrane traffic in the RPE we used a cell type-specific knock-out mouse model of the disease, where the Chm/Rep1 gene is deleted only in pigmented cells (Chm(Flox, Tyr-Cre+. Transmission electron microscopy (TEM was used to quantitate the melanosome distribution in the RPE and immunofluorescent staining of rhodopsin was used to quantitate phagocytosed rod outer segments in retinal sections. The ultrastructure of the RPE and Bruch's membrane at different ages was characterised by TEM to analyse age-related changes occurring as a result of defects in membrane traffic pathways. Chm/Rep1 gene knockout in RPE cells resulted in reduced numbers of melanosomes in the apical processes and delayed phagosome degradation. In addition, the RPE accumulated pathological changes at 5-6 months of age similar to those observed in 2-year old controls. These included the intracellular accumulation of lipofuscin-containing deposits, disorganised basal infoldings and the extracellular accumulation of basal laminar and basal linear deposits. The phenotype of the Chm(Flox, Tyr-Cre+ mice suggests that loss of the Chm/Rep1 gene causes premature accumulation of features of aging in the RPE. Furthermore, the striking similarities between the present observations and some of the phenotypes reported in age-related macular degeneration (AMD suggest that membrane traffic defects may contribute to the pathogenesis of AMD.

  7. Absence of superoxide dismutase activity causes nuclear DNA fragmentation during the aging process

    International Nuclear Information System (INIS)

    Muid, Khandaker Ashfaqul; Karakaya, Hüseyin Çaglar; Koc, Ahmet

    2014-01-01

    Highlights: • Aging process increases ROS accumulation. • Aging process increases DNA damage levels. • Absence of SOD activity does not cause DNA damage in young cells. • Absence of SOD activity accelerate aging and increase oxidative DNA damages during the aging process. - Abstract: Superoxide dismutases (SOD) serve as an important antioxidant defense mechanism in aerobic organisms, and deletion of these genes shortens the replicative life span in the budding yeast Saccharomyces cerevisiae. Even though involvement of superoxide dismutase enzymes in ROS scavenging and the aging process has been studied extensively in different organisms, analyses of DNA damages has not been performed for replicatively old superoxide dismutase deficient cells. In this study, we investigated the roles of SOD1, SOD2 and CCS1 genes in preserving genomic integrity in replicatively old yeast cells using the single cell comet assay. We observed that extend of DNA damage was not significantly different among the young cells of wild type, sod1Δ and sod2Δ strains. However, ccs1Δ mutants showed a 60% higher amount of DNA damage in the young stage compared to that of the wild type cells. The aging process increased the DNA damage rates 3-fold in the wild type and more than 5-fold in sod1Δ, sod2Δ, and ccs1Δ mutant cells. Furthermore, ROS levels of these strains showed a similar pattern to their DNA damage contents. Thus, our results confirm that cells accumulate DNA damages during the aging process and reveal that superoxide dismutase enzymes play a substantial role in preserving the genomic integrity in this process

  8. Towards plant wires

    OpenAIRE

    Adamatzky, Andrew

    2014-01-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self...

  9. Age at natural menopause in relation to all-cause and cause-specific mortality in a follow-up study of US black women.

    Science.gov (United States)

    Li, Se; Rosenberg, Lynn; Wise, Lauren A; Boggs, Deborah A; LaValley, Michael; Palmer, Julie R

    2013-07-01

    Early age at natural menopause has been associated with increased all-cause mortality in several studies, although the literature is not consistent. This relation has not been examined among African American women. Data were from the Black Women's Health Study, a follow-up study of African-American women enrolled in 1995. Among 11,212 women who were naturally menopausal at entry to the study or during follow-up through 2008, we assessed the relation of age at natural menopause to all-cause and cause-specific mortality. At baseline and biennially, participants reported on reproductive and medical history, including gynecologic surgeries and exogenous hormone use. Mortality data were obtained from the National Death Index. Multivariable Cox proportional hazard models were used to estimate mortality rate ratios (MRR) and 95% confidence intervals (CI) for categories of age at menopause. Of 692 deaths identified during 91,829 person years of follow-up, 261 were due to cancer, 199 to cardiovascular diseases and 232 to other causes. Natural menopause before age 40 was associated with increased all-cause mortality (MRR=1.34, 95% CI 0.96-1.84, relative to menopause at 50-54 years; P-trend=0.04) and with the subcategories of death considered - cancer, cardiovascular disease, and all other causes. The associations were present among never and ever users of postmenopausal female hormones and among never and ever smokers. In this large prospective cohort of African-American women, natural menopause before age 40 was associated with a higher rate of all-cause and cause-specific mortality. These findings provide support for the theory that natural menopause before age 40 may be a marker of accelerated somatic aging. Published by Elsevier Ireland Ltd.

  10. Aging and Spinal Cord Injury: External Causes of Injury and Implications for Prevention.

    Science.gov (United States)

    Chen, Yuying; Tang, Ying; Allen, Victoria; DeVivo, Michael J

    2015-01-01

    Despite a consistent trend toward older age at time of spinal cord injury (SCI), little is known about the external causes of SCI in the elderly. To examine environmental circumstances, documented by International Classification of Diseases, 10th Revision, Clinical Modification codes, at time of SCI among older adults. Data on individuals injured in 2005 or later were retrieved from the National SCI Database. Demographics, injury profiles, and external causes of injury were compared between the study group (age >60 years, n = 1,079) and reference group (age 16-45 years, n = 3,579) using chi-square and Student t tests. Among the elderly, falls were the most common etiology of SCI (60%), followed by transport accidents (24%) and complications of medical and surgical care (12%). In the younger group, transport accidents were the most common etiology of SCI (49%), followed by falls (22%) and assault (21%). Falls on the same level (30%), from stairs and steps (22%), and other slipping, tripping, and stumbling (11%) were the most common mechanisms of falls in the elderly group. Among motor vehicle accidents, car occupant injured in a collision with another car was the most common mechanism of injury among the elderly (28%). There is an urgent need for effective fall prevention programs among the elderly to reduce SCI in this expanding population. Details on the mechanisms of falls and other major causes of SCI among the elderly provided in this study should inform the development of future interventions for high-risk persons, activities, and environments.

  11. Photovoltaic Wire, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  12. Photovoltaic Wire Project

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase I project will investigate a new architecture for photovoltaic devices based on nanotechnology: photovoltaic wire. The...

  13. Charpak hemispherical wire chamber

    CERN Document Server

    1970-01-01

    pieces. Mesures are of the largest one. Multi-wire detectors contain layers of positively and negatively charged wires enclosed in a chamber full of gas. A charged particle passing through the chamber knocks negatively charged electrons out of atoms in the gas, leaving behind positive ions. The electrons are pulled towards the positively charged wires. They collide with other atoms on the way, producing an avalanche of electrons and ions. The movement of these electrons and ions induces an electric pulse in the wires which is collected by fast electronics. The size of the pulse is proportional to the energy loss of the original particle.

  14. [Diarrhoea-causing agents in children aged less than five in Tunja, Colombia].

    Science.gov (United States)

    Manrique-Abril, Fred G; Tigne y Diane, Billon; Bello, Sandra E; Ospina, Juan M

    2006-01-01

    Determining the prevalence and type of infectious ADD-causing agents in a sample of children aged less than five who consulted the IPS in Tunja during 2004. A cross-sectional study was designed. Data was obtained by surveying 129 children younger than 5 suffering from ADD. Samples of faeces were obtained following outpatient consultation at San Rafael Hospital and SaludCoop's clinic in Tunja. Rotavirus was found in 48.1% of cases, Shigella in 0.8%, E. coli in 13.9%, Campylobacter in 2.3%, Giardia lamblia in 12.4% and E. hitolytica in 7%. The causative agent could not be identified in 15.5% of cases. The statistical association grew with age for Rotavirus (p data reported in studies carried out in Facatatativá, Bogotá, Santander, Manizales and the Chocó in Colombia and studies carried out in Venezuela, Peru and Mexico.

  15. Biliary Stones: An atypical cause of abdominal pain in Paediatric age group

    International Nuclear Information System (INIS)

    Mehmood, A.; Khan, A.M.

    2010-01-01

    Objective: To identify Paediatric patients with biliary stone disease presenting to a tertiary care hospital in order to determine the etiology, presentation and management. Methods: Retrospective study of all cases of ultrasonographically proven biliary stones under the age of 15 years from January 1988 to December 2008. Data included their risk factors, complications, management and outcome. Results: Total 32 patients were identified with biliary stones, treated in the hospital. Mean age at presentation was 8.25 +- 3.33 years. Sixteen patients underwent cholecystectomy. Conclusion: Paediatric cholelithiasis is an atypical and under-diagnosed cause of abdominal pain in childhood. True prevalence of the disease may be higher than reported. Appropriate surgical intervention is required in patients with symptomatic and complicated biliary lithiasis. (author)

  16. 1998 wire development workshop proceedings

    International Nuclear Information System (INIS)

    1998-04-01

    This report consists of vugraphs of the presentations at the conference. The conference was divided into the following sessions: (1) First Generation Wire Development: Status and Issues; (2) First Generation Wire in Pre-Commercial Prototypes; (3) Second Generation Wire Development: Private Sector Progress and Issues; (4) Second Generation Wire Development: Federal Laboratories; and (5) Fundamental Research Issues for HTS Wire Development

  17. The causes of difficult tracheal intubation and preoperative assessments in different age groups

    Science.gov (United States)

    Moon, Hyoung-Yong; Kim, Jin-Seo; Koo, Gill Hoi; Kim, Jin-Yun; Woo, Young-Cheol; Jung, Yong Hun; Kang, Hyun; Shin, Hwa-Yong; Yang, So-Young

    2013-01-01

    Background We studied the differences in airway assessment factors among old, middle, and young age groups, and evaluated the frequency and causes of difficult intubation among these groups. Methods Patients were divided into young (Cormack-Lehane (C-L) grade were assessed. The differences in airway assessment factors between difficult (C-L grade 3, 4) and easy (C-L grade 1, 2) intubation were then examined. Logistic regression analysis was also carried out to identify the extent to which airway assessment factors reflected difficult intubation. Results As aging, head and neck movement, thyromental distance, and interincisor gap decreased, the grade of dentition, Mallampati score, cervical joint rigidity and the ratio of Arné score > 11 increased. In the old and middle group, the incidence of difficult intubation was increased compared with the young group. Dentition in the young group, Mallampati score and interinsisor gap in the middle group and Mallampati score, cervical joint rigidity in the old group respectively predicted difficult intubation. Conclusions Compared to young individuals, middle-aged or elderly adults are likely to experience more difficulty in endotracheal intubation and its predictive factors could vary by age group. PMID:23646239

  18. Combining an Electrothermal and Impedance Aging Model to Investigate Thermal Degradation Caused by Fast Charging

    Directory of Open Access Journals (Sweden)

    Joris de Hoog

    2018-03-01

    Full Text Available Fast charging is an exciting topic in the field of electric and hybrid electric vehicles (EVs/HEVs. In order to achieve faster charging times, fast-charging applications involve high-current profiles which can lead to high cell temperature increase, and in some cases thermal runaways. There has been some research on the impact caused by fast-charging profiles. This research is mostly focused on the electrical, thermal and aging aspects of the cell individually, but these factors are never treated together. In this paper, the thermal progression of the lithium-ion battery under specific fast-charging profiles is investigated and modeled. The cell is a Lithium Nickel Manganese Cobalt Oxide/graphite-based cell (NMC rated at 20 Ah, and thermal images during fast-charging have been taken at four degradation states: 100%, 90%, 85%, and 80% State-of-Health (SoH. A semi-empirical resistance aging model is developed using gathered data from extensive cycling and calendar aging tests, which is coupled to an electrothermal model. This novel combined model achieves good agreement with the measurements, with simulation results always within 2 °C of the measured values. This study presents a modeling methodology that is usable to predict the potential temperature distribution for lithium-ion batteries (LiBs during fast-charging profiles at different aging states, which would be of benefit for Battery Management Systems (BMS in future thermal strategies.

  19. Wire Array Photovoltaics

    Science.gov (United States)

    Turner-Evans, Dan

    Over the past five years, the cost of solar panels has dropped drastically and, in concert, the number of installed modules has risen exponentially. However, solar electricity is still more than twice as expensive as electricity from a natural gas plant. Fortunately, wire array solar cells have emerged as a promising technology for further lowering the cost of solar. Si wire array solar cells are formed with a unique, low cost growth method and use 100 times less material than conventional Si cells. The wires can be embedded in a transparent, flexible polymer to create a free-standing array that can be rolled up for easy installation in a variety of form factors. Furthermore, by incorporating multijunctions into the wire morphology, higher efficiencies can be achieved while taking advantage of the unique defect relaxation pathways afforded by the 3D wire geometry. The work in this thesis shepherded Si wires from undoped arrays to flexible, functional large area devices and laid the groundwork for multijunction wire array cells. Fabrication techniques were developed to turn intrinsic Si wires into full p-n junctions and the wires were passivated with a-Si:H and a-SiNx:H. Single wire devices yielded open circuit voltages of 600 mV and efficiencies of 9%. The arrays were then embedded in a polymer and contacted with a transparent, flexible, Ni nanoparticle and Ag nanowire top contact. The contact connected >99% of the wires in parallel and yielded flexible, substrate free solar cells featuring hundreds of thousands of wires. Building on the success of the Si wire arrays, GaP was epitaxially grown on the material to create heterostructures for photoelectrochemistry. These cells were limited by low absorption in the GaP due to its indirect bandgap, and poor current collection due to a diffusion length of only 80 nm. However, GaAsP on SiGe offers a superior combination of materials, and wire architectures based on these semiconductors were investigated for multijunction

  20. Histopathological Study of Splenectomy Specimens with Correlation with Age, Sex, and Cause of Splenectomy.

    Directory of Open Access Journals (Sweden)

    Dr Hiral Patel

    2016-12-01

    Full Text Available Spleen is mysterious organ. It can be troublesome specimen for surgical pathologist due to discordance between patient’s clinical condition and perceived finding. The weight of spleen is about 150 grams and lies beneath 9th to 12th thoracic rib in healthy adult and between fundus of stomach & diaphragm. It composed of red pulp (76-79% and white pulp (5-20% which are separated by marginal zone. A total of 100 cases were studied at histopathology section of our laboratory during the period of January 2015 to December 2015. The specimens were received in 10% neutral buffer formalin with duly filled request form. All specimens were examined macroscopically. After routine processing the sections were stained with routine haematoxylin and eosin stain. The most common age group to be affected is 3rd decade (29%, next was 4th decade (23% with slightly male predominance. Male: female ratio is 1.3:1. Most common cause for splenectomy was portal hypertension (33% followed by trauma (15%. Most common microscopic finding is fibrocongestive splenomegaly (68% which is correlated with clinical and radiological finding. In adult Portal hypertension as a hepatic cause and in paediatric age group thalassemia is the most common indication for splenectomy.

  1. Initial arch wires for alignment of crooked teeth with fixed orthodontic braces.

    LENUS (Irish Health Repository)

    Wang, Yan

    2010-01-01

    The initial arch wire is the first arch wire to be inserted into the fixed appliance at the beginning of orthodontic treatment and is used mainly for correcting crowding and rotations of teeth. With a number of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment.

  2. Exercise capacity and all-cause mortality in male veterans with hypertension aged ≥70 years.

    Science.gov (United States)

    Faselis, Charles; Doumas, Michael; Pittaras, Andreas; Narayan, Puneet; Myers, Jonathan; Tsimploulis, Apostolos; Kokkinos, Peter

    2014-07-01

    Aging, even in otherwise healthy subjects, is associated with declines in muscle mass, strength, and aerobic capacity. Older individuals respond favorably to exercise, suggesting that physical inactivity plays an important role in age-related functional decline. Conversely, physical activity and improved exercise capacity are associated with lower mortality risk in hypertensive individuals. However, the effect of exercise capacity in older hypertensive individuals has not been investigated extensively. A total of 2153 men with hypertension, aged ≥70 years (mean, 75 ± 4) from the Washington, DC, and Palo Alto Veterans Affairs Medical Centers, underwent routine exercise tolerance testing. Peak workload was estimated in metabolic equivalents (METs). Fitness categories were established based on peak METs achieved, adjusted for age: very-low-fit, 2.0 to 4.0 METs (n=386); low-fit, 4.1 to 6.0 METs (n=1058); moderate-fit, 6.1 to 8.0 METs (n=495); high-fit >8.0 METs (n=214). Cox proportional hazard models were applied after adjusting for age, body mass index, race, cardiovascular disease, cardiovascular medications, and risk factors. All-cause mortality was quantified during a mean follow-up period of 9.0 ± 5.5 years. There were a total of 1039 deaths or 51.2 deaths per 1000 person-years of follow-up. Mortality risk was 11% lower (hazard ratio, 0.89; 95% confidence interval, 0.86-0.93; Pexercise capacity. When compared with those achieving ≤4.0 METs, mortality risk was 18% lower (hazard ratio, 0.82; 95% confidence interval, 0.70-0.95; P=0.011) for the low-fit, 36% for the moderate-fit (hazard ratio, 0.64; 95% confidence interval, 0.52-0.78; Pexercise capacity is associated with lower mortality risk in elderly men with hypertension. © 2014 American Heart Association, Inc.

  3. Population-based study of age, gender and causes of severe injury in Auckland, 2004.

    Science.gov (United States)

    Creamer, Gowan L; Civil, Ian; Koelmeyer, Timothy; Adams, David; Cacala, Shas; Thompson, John

    2008-11-01

    The burden of severe injury is an important health statistic. When accurate injury data are linked to census population data a reference dataset can be obtained. This information is vital to direct injury prevention and trauma system development. Severe injury was defined as death or injury severity score more than 15. Resident population projections for the Auckland region (2004) were provided by New Zealand Statistics. Combining data from coronial autopsy and four hospital trauma databases provided age, sex, mechanism, mortality and hospitalization information for severely injured Aucklanders. Mechanism groupings were both blunt, penetrating or burn; and activity based (motor vehicle related (occupant and pedestrian), falls, hanging, assault, burns, sports, playing, aircraft, boating and work related). Four hundred and forty-eight Auckland residents had severe injuries of which 192 died. The mortality and severe injury rates (includes mortality) were 14.4/100,000 and 33.6/100,000, respectively. Groups that were overrepresented in the population were male sex, those aged 15-29, those aged >75. Injury rate was lowest in those aged 0-14 years. Injury causes were motor vehicle related (50%), falls (19%), hangings (15%), assault (11%) and other: burns, work related, sports, playing, aircraft and boating related (5%) and 3.8% of cases were from penetrating mechanism. Hangings, road traffic crashes, assaults and falls had at-scene mortality rates of 100, 26, 25 and 6% and inpatient mortality rates of 0, 11, 4 and 17%, respectively (P Auckland has a severe injury rate that is lower than other similar studies. Contributing factors include: low interpersonal violence rates, the predominantly urban population, the data source and the inclusion of the paediatric age group.

  4. Examination of the common cause account in a population-based longitudinal study with narrow age cohort design.

    Science.gov (United States)

    Sternäng, Ola; Jonsson, Bert; Wahlin, Ake; Nyberg, Lars; Nilsson, Lars-Göran

    2010-01-01

    The common cause account suggests that there is a third factor causing aging effects in both sensory and cognitive functioning, hypothesized to be the integrity of the central nervous system [Lindenberger and Baltes; Psychol Aging 1994;9:339-355]. Importantly, the common cause account was developed based on cross-sectional data, which are especially biased by cohort effects. However, cohort effects can be controlled for in narrow age cohort (NAC) designs and by longitudinal examination. Findings from the few longitudinal studies that have studied the relation between age-related changes in sensory and cognitive functions are complex and give only partial support to the common cause account. The present paper examines the common cause account within a longitudinal setting. Our study is unique in the sense that it tests the common cause account within a longitudinal NAC design using data from the Betula project. The participants (n = 1,057) were in the age range of 45-90 years. The findings indicate that the relationship between sensory and memory functioning in both a longitudinal age-heterogeneous and a longitudinal NAC design are much weaker than that detected by an age-heterogeneous cross-sectional design. The demonstrated weak age-associated sensory-cognitive link raises questions regarding the explanatory value of the common cause account and related theoretical accounts for accounting for age-related cognitive changes. Copyright © 2010 S. Karger AG, Basel.

  5. Automating wiring formboard design

    NARCIS (Netherlands)

    Van den Berg, T.

    2013-01-01

    Increase in aircraft wiring complexity call for manufacturing design improvements to reduce cost and lead-time. To achieve such improvements, a joint research project was performed by the Flight Performance and Propulsion (FPP) group and Fokker Elmo BV, the second largest aircraft wiring harness

  6. Maternal education and stillbirth: estimating gestational-age-specific and cause-specific associations.

    Science.gov (United States)

    Auger, Nathalie; Delézire, Pauline; Harper, Sam; Platt, Robert W

    2012-03-01

    Associations between risk factors and perinatal outcomes may be biased at preterm gestational ages, if preterm delivery behaves as an effect modifier due to other unmeasured factors in the causal pathway. We evaluated whether fetuses-at-risk denominators could be used in regression models instead of conventional denominators to obtain less biased estimates of the association between maternal education and stillbirth at preterm gestational intervals. Data included 2,143,134 live-born and 8946 stillborn singletons from 1981 through 2006 in Québec, Canada. Odds ratios and 95% confidence intervals were estimated for the relationship between education and stillbirth according to cause of fetal death, adjusting for maternal age, marital status, home language, parity, and period. We examined associations for 4 gestational intervals (education at all gestational intervals. Using conventional denominators, low education (relative to high education) was more strongly associated with term than preterm stillbirth and was apparently protective at education was more strongly associated with preterm stillbirth than term stillbirth, even at education was most strongly associated with diabetic-related stillbirth at ≥28 weeks (odds ratio = 5.04) relative to high education. Low education is associated with stillbirth throughout gestation, especially diabetic-related stillbirth. Use of fetuses-at-risk denominators in regression models can avoid potentially biased estimates obtained with conventional denominators at preterm gestational ages.

  7. Modifications in straight wire treatment.

    Science.gov (United States)

    Cardona, Alvin

    2010-01-01

    Orthodontic treatments have been modified with each new generation of clinicians. Today the emphasis is on facial esthetics and healthy temporomandibular joints. With orthopedic treatment, we can develop dental arches to get the necessary space to align the teeth and we can reach adequate function and esthetics, all within relatively good stability. By combining two-phase treatment with low friction fixed orthodontics and super elastic wires we produce light but continuous forces and we can provide better treatment than before. These types of forces cause physiological and functional orthopedic orthodontic reactions. The purpose of this article is to demonstrate our fixed orthopedic and orthodontic approach called "Modified Straight Wire" or "Physiologic Arch Technique." This technique is very successful with our patients because it can exert slow and continuous forces with minimal patient cooperation.

  8. Frailty syndrome and all-cause mortality in demented patients: the Italian Longitudinal Study on Aging.

    Science.gov (United States)

    Solfrizzi, Vincenzo; Scafato, Emanuele; Frisardi, Vincenza; Sancarlo, Daniele; Seripa, Davide; Logroscino, Giancarlo; Baldereschi, Marzia; Crepaldi, Gaetano; Di Carlo, Antonio; Galluzzo, Lucia; Gandin, Claudia; Inzitari, Domenico; Maggi, Stefania; Pilotto, Alberto; Panza, Francesco

    2012-04-01

    Cognition has already been considered as a component of frailty, and it has been demonstrated that it is associated with adverse health outcomes. We estimated the prevalence of frailty syndrome in an Italian older population and its predictive role on all-cause mortality and disability in nondemented subjects and in demented patients. We evaluated 2,581 individuals recruited from the Italian Longitudinal Study on Aging, a population-based sample of 5,632 subjects, aged 65-84 years old. Participants received identical baseline evaluation at the 1st survey (1992-1993) and were followed at 2nd (1995-1996) and 3rd survey (2000-2001). A phenotype of frailty according to partially modified measurement of Cardiovascular Health Study criteria was operationalized. The overall prevalence of frailty syndrome in this population-based study was 7.6% (95% confidence interval (CI) 6.55-8.57). Frail individuals noncomorbid or nondisable were 9.1% and 39.3%, respectively, confirming an overlap but not concordance in the co-occurrence among these conditions. Frailty was associated with a significantly increased risk of all-cause mortality over a 3-year follow-up (hazard ratio (HR) 1.98, 95% confidence interval (CI) 1.52-2.60) and over a 7-year follow-up (HR 1.74, 95% CI 1.44-2.16), but with significant increased risk of disability only over a 3-year follow-up (HR 1.32, 95% CI 1.06-1.86 over a 3-year follow-up and HR 1.16, 95% CI 0.88-1.56 over a 7-year follow-up). Frail demented patients were at higher risk of all-cause mortality over 3- (HR 3.33, 95% CI 1.28-8.29) and 7-year follow-up periods (HR 1.89, 95% CI 1.10-3.44), but not of disability. Frailty syndrome was a short-term predictor of disability in nondemented older subjects and short- and long-term predictor of all-cause mortality in nondemented and demented patients.

  9. Loss of autophagy in dopaminergic neurons causes Lewy pathology and motor dysfunction in aged mice.

    Science.gov (United States)

    Sato, Shigeto; Uchihara, Toshiki; Fukuda, Takahiro; Noda, Sachiko; Kondo, Hiromi; Saiki, Shinji; Komatsu, Masaaki; Uchiyama, Yasuo; Tanaka, Keiji; Hattori, Nobutaka

    2018-02-12

    Inactivation of constitutive autophagy results in the formation of cytoplasmic inclusions in neurons, but the relationship between impaired autophagy and Lewy bodies (LBs) as well as the in vivo process of formation remains unknown. Synuclein, a component of LBs, is the defining characteristic of Parkinson's disease (PD). Here, we characterize dopamine (DA) neuron-specific autophagy-deficient mice and provide in vivo evidence for LB formation. Synuclein deposition is preceded by p62 and resulted in the formation of inclusions containing synuclein and p62. The number and size of these inclusions were gradually increased in neurites rather than soma with aging. These inclusions may facilitate peripheral failures. As a result, DA neuron loss and motor dysfunction including the hindlimb defect were observed in 120-week-old mice. P62 aggregates derived from an autophagic defect might serve as "seeds" and can potentially be cause of LB formation.

  10. A method for projecting age-specific mortality rates for certain causes of death

    International Nuclear Information System (INIS)

    Leggett, R.W.; Crawford, D.J.

    1981-01-01

    A method is presented for projecting mortality rates for certain causes on the basis of observed rates during past years. This method arose from a study of trends in age-specific mortality rates for respiratory cancers, and for heuristic purposes it is shown how the method can be developed from certain theories of cancer induction. However, the method is applicable in the more common situation in which the underlying physical processes cannot be modeled with any confidence but the mortality rates are approximable over short time intervals by functions of the form a exp(bt), where b may vary in a continuous, predictable fashion as the time interval is varied. It appears from applications to historical data that this projection method is in some cases a substantial improvement over conventional curve-fitting methods and often uncovers trends which are not from observed data

  11. THE CAUSES AND THE COURSE OF CHRONIC KIDNEY DISEASE IN CHILDREN OF PRESCHOOL AGE

    Directory of Open Access Journals (Sweden)

    T. Yu. Abaseeva

    2015-01-01

    Full Text Available Background: Data on etiology and clinical course of CKD stage  3 to 5 in children of preschool  age could help obstetricians, pediatricians, and nephrologists with proper diagnostics and management of this condition and prediction of outcomes. Aim: To study causes and clinical features of CKD stage 3 to 5 in preschool  children. Materials and methods: The causes and clinical features of CKD stage 3 to 5 were investigated in 55 preschool children aged from 7 months  to 8 years. Twenty four had  CKD stage  3 to 4 and  31 children with endstage  CKD  were  on  peritoneal  dialysis. Results:96% of CKD stage 3 to 5 in preschool children were due  to  congenital/genetic kidney abnormalities. Predictors  of renal  replacement therapy  beginning in the first 5 years of life were as follows: antenatal detection of congenital  abnormalities  of the kidney and urinary tract, oligohydroamnion, high neonatal  BUN levels.  Anemia, hyperparathyroidism, arterial hypertension were more prevalent  in children on the dialysis stage of CKD, and myocardial hypertrophy and/or of the left ventricle dilatation were found in 26% of them. Forty two percent of children had growth retardation, and 40% had delayed  speech  development. Conclusion: The course CKD in preschool  children is characterized by a combination of typical metabolic  disorders with the growth  retardation (often dramatic and delayed mental development that significantly limits the possibilities of the social adaptation of these children and social activities of their parents. Participation  of  neuropsychiatrists,  clinical psychologists, and teachers, rather than pediatricians and  nephrologists only, is desirable  in management of preschool children with CKD stage 3 to 5.

  12. Research regarding stiffness optimization of wires used for joints actuation from an elephant's trunk robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-11-01

    Elephant's trunk robotic arms driven by wires and pulley mechanisms have issues with wires stiffness because of the entailed elastic deformations that is causing errors of positioning. Static and dynamic loads from each joint of the robotic arm affect the stiffness of driving wires and precision positioning. The influence of wires elastic deformation on precision positioning decreases with the increasing of wires stiffness by using different pre-tensioning devices. In this paper, we analyze the variation of driving wires stiffness particularly to each wire driven joint. We obtain optimum wires stiffness variation by using an analytical method that highlights the efficiency of pre-tensioning mechanism. The analysis of driving wires stiffness is necessary for taking appropriate optimization measures of robotic arm dynamic behavior and, thus, for decreasing positioning errors of the elephant's trunk robotic arm with inner actuation through wires/cables.

  13. Psychological adjustment to amputation: variations on the bases of sex, age and cause of limb loss

    International Nuclear Information System (INIS)

    Ali, S.; Haider, S.K.F.

    2017-01-01

    Amputation is the removal of a limb or part of a limb by a surgical procedure in order to save the life of a person. The underlying reasons behind the occurrence of this tragic incidence may be varied. However, irrespective of its cause limb loss is associated with wide range of life challenges. The study was done to investigate the psychological sequel of an individual after losing a limb and to know the level of strain and pressure they experience after this traumatic event. It also attempts to examine the moderating role of some demographic traits such as age, sex and cause of limb loss in psychosocial adjustment to amputation. Methods: The study includes 100 adult amputees of both genders and the data was collected from major government and private hospitals of Peshawar district. Demographic data sheet was constructed in order to know the demographics traits of amputees and a standardize Psychological Adjustment Scale developed by Sabir (1999) was used to find out the level of psychological adjustment after limb loss. Results: Nearly all the amputees' exhibit signs of psychological maladjustment at varying degrees. Males showed much greater signs of maladjustment than women and young adults were much psychologically shattered and disturbed as a result of limb loss. Amputation caused by planned medical reasons leads to less adjustment issues as compared to unplanned accidental amputation in which patient were not mentally prepare to accept this loss. Conclusion: Psychological aspect of amputation is an important aspect of limb loss which needs to be addressed properly in order to rehabilitate these patients and helps them to adjust successfully to their limb loss. (author)

  14. Decomposition of educational differences in life expectancy by age and causes of death among South Korean adults.

    Science.gov (United States)

    Jung-Choi, Kyunghee; Khang, Young-Ho; Cho, Hong-Jun; Yun, Sung-Cheol

    2014-06-05

    Decomposition of socioeconomic inequalities in life expectancy by ages and causes allow us to better understand the nature of socioeconomic mortality inequalities and to suggest priority areas for policy and intervention. This study aimed to quantify age- and cause-specific contributions to socioeconomic differences in life expectancy at age 25 by educational level among South Korean adult men and women. We used National Death Registration records in 2005 (129,940 men and 106,188 women) and national census data in 2005 (15, 215, 523 men and 16,077,137 women aged 25 and over). Educational attainment as the indicator of socioeconomic position was categorized into elementary school graduation or less, middle or high school graduation, and college graduation or higher. Differences in life expectancy at age 25 by educational level were estimated by age- and cause-specific mortality differences using Arriaga's decomposition method. Differences in life expectancy at age 25 between college or higher education and elementary or less education were 16.23 years in men and 7.69 years in women. Young adult groups aged 35-49 in men and aged 25-39 in women contributed substantially to the differences between college or higher education and elementary or less education in life expectancy. Suicide and liver disease were the most important causes of death contributing to the differences in life expectancy in young adult groups. For older age groups, cerebrovascular disease and lung cancer were important to explain educational differential in life expectancy at 25-29 between college or higher education and middle or higher education. The contribution of the causes of death to socioeconomic inequality in life expectancy at age 25 in South Korea varied by age groups and differed by educational comparisons. The age specific contributions for different causes of death to life expectancy inequalities by educational attainment should be taken into account in establishing effective policy

  15. Aging of gaseous detectors

    International Nuclear Information System (INIS)

    Va'Vra, J.

    1990-03-01

    This paper makes an overview of developments in the wire chamber aging field since the wire chamber aging workshop held at the Lawrence Berkeley Laboratory, Berkeley, California on January 16--17, 1986. The author discusses new techniques to analyze the gas impurities and the wire aging products, wire ''nonaging'' in clean systems, wire aging in systems containing various impurities, various examples of problems which can ''prime'' surfaces prior to the occurrence of the aging, and some recent aging experience with the ''SSC micro-straw tubes.'' 35 refs., 10 figs., 2 tabs

  16. The sub-wavelength imaging performance of disordered wire media

    International Nuclear Information System (INIS)

    Powell, David A.

    2008-01-01

    An analysis of the sub-wavelength imaging performance of disordered thin wire media is undertaken, in order to understand how its performance may be affected by manufacturing errors. The structure is found to be extremely robust to disorder which keeps the wires parallel. Variation in the orientation of the wires and their longitudinal position causes more significant degradation in the image quality, which is quantified numerically

  17. Thermosonic wire bonding of IC devices using palladium wire

    International Nuclear Information System (INIS)

    Shze, J.H.; Poh, M.T.; Tan, R.M.

    1996-01-01

    The feasibility of replacing gold wire by palladium wire in thermosonic wire bonding of CMOS and bipolar devices are studied in terms of the manufacturability, physical, electrical and assembly performance. The results that palladium wire is a viable option for bonding the bipolar devices but not the CMOS devices

  18. Fluoride influences nickel-titanium orthodontic wires' surface texture and friction resistance.

    Science.gov (United States)

    Abbassy, Mona Aly

    2016-01-01

    The aim of this study was to investigate the effects exerted by the acidulated fluoride gel on stainless steel and nickel-titanium (Ni-Ti) orthodontic wires. Sixty stainless steel and Ni-Ti orthodontic archwires were distributed into forty archwires used for in vitro study and twenty for in situ study. Fluoride was applied for 1 h in the in vitro experiment while it was applied for 5 min in the in situ experiment. The friction resistance of all wires with ceramic brackets before/after topical fluoride application was measured using a universal testing machine at 1 min intervals of moving wire. Moreover, surface properties of the tested wires before/after fluoride application and before/after friction test were examined by a scanning electron microscope (SEM). Dunnett's t -test was used to compare frictional resistance of as-received stainless steel wires and Ni-Ti wires to the wires treated by fluoride in vitro and in situ ( P wire on friction resistance in vitro and in situ ( P wires recorded significantly high friction resistance after fluoride application when compared to stainless steel wires in vitro , P wires in situ , P wires after fluoride application in vitro and in situ . The in vitro fluoride application caused an increase in friction resistance of Ni-Ti wires when compared to stainless steel wires. In vitro and in situ fluoride application caused deterioration in surface properties of Ni-Ti wires.

  19. Towards plant wires.

    Science.gov (United States)

    Adamatzky, Andrew

    2014-08-01

    In experimental laboratory studies we evaluate a possibility of making electrical wires from living plants. In scoping experiments we use lettuce seedlings as a prototype model of a plant wire. We approximate an electrical potential transfer function by applying direct current voltage to the lettuce seedlings and recording output voltage. We analyse oscillation frequencies of the output potential and assess noise immunity of the plant wires. Our findings will be used in future designs of self-growing wetware circuits and devices, and integration of plant-based electronic components into future and emergent bio-hybrid systems. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  20. Testosterone deficiency causes penile fibrosis and organic erectile dysfunction in aging men. Evaluating association among Age, TDS and ED

    Directory of Open Access Journals (Sweden)

    Iacono Fabrizio

    2012-11-01

    Full Text Available Abstract Introduction We studied the possible correlation between age, testosterone deficiency, cavernosal fibrosis and erectile dysfunction (ED. Methods 47 patients with ED were enrolled between September 2010 and October 2011. IIEF-EF score, NPTR test using the Rigiscan method, total and free testosterone levels, and cavernosum biopsy were carried out on all patients. Patients aged 65 or over were defined as Old Age (OA while patients under 65 were defined Young age (YA. The strength of the relationships found was estimated by Odds Ratio. Results 74% of patients with values of over 52% collagen fibers in the corpora cavernosa were found to have organic ED. A significant difference was found in age, percentage of collagen fibers, testosterone levels between patients with Positive Rigiscan (PR and Negative Rigiscan (NR. Hypotestosteronaemia increased the risk of ED with PR (OR: 21.4, 95% CI: 20.2-22.6 and in both young age patients (OR: 4.3, 95% CI: 2.4-6.2 and old age patients (OR: 15.5, 95% CI: 13.4-17.6. Moreover cavernosal fibrosis increased the risk of ED with PR in both young age patients (OR: 8.2, 95% CI: 6.4-10.0 and old age patients (OR: 24.6, 95% CI: 20.8-28.4. Conclusions This study demonstrates a strong association among age, testosterone deficiency, cavernosal fibrosis and ED with PR. Age, testosterone deficiency and cavernosal fibrosis are potentially correctable factors of cavernosal fibrosis and organic ED. Further, prospective studies are needed to evaluate if testosterone treatment, alone or in association with PDE5 inhibitors, may lower the risk of cavernosal fibrosis or decrease the severity the fibrosis in ED patients.

  1. Testosterone deficiency causes penile fibrosis and organic erectile dysfunction in aging men. Evaluating association among Age, TDS and ED.

    Science.gov (United States)

    Iacono, Fabrizio; Prezioso, Domenico; Ruffo, Antonio; Illiano, Ester; Romis, Leo; Di Lauro, G; Romeo, Giuseppe; Amato, Bruno

    2012-01-01

    We studied the possible correlation between age, testosterone deficiency, cavernosal fibrosis and erectile dysfunction (ED). 47 patients with ED were enrolled between September 2010 and October 2011. IIEF-EF score, NPTR test using the Rigiscan method, total and free testosterone levels, and cavernosum biopsy were carried out on all patients. Patients aged 65 or over were defined as Old Age (OA) while patients under 65 were defined Young age (YA). The strength of the relationships found was estimated by Odds Ratio. 74% of patients with values of over 52% collagen fibers in the corpora cavernosa were found to have organic ED. A significant difference was found in age, percentage of collagen fibers, testosterone levels between patients with Positive Rigiscan (PR) and Negative Rigiscan (NR). Hypotestosteronaemia increased the risk of ED with PR (OR: 21.4, 95% CI: 20.2-22.6) and in both young age patients (OR: 4.3, 95% CI: 2.4-6.2) and old age patients (OR: 15.5, 95% CI: 13.4-17.6). Moreover cavernosal fibrosis increased the risk of ED with PR in both young age patients (OR: 8.2, 95% CI: 6.4-10.0 and old age patients (OR: 24.6, 95% CI: 20.8-28.4). This study demonstrates a strong association among age, testosterone deficiency, cavernosal fibrosis and ED with PR. Age, testosterone deficiency and cavernosal fibrosis are potentially correctable factors of cavernosal fibrosis and organic ED. Further, prospective studies are needed to evaluate if testosterone treatment, alone or in association with PDE5 inhibitors, may lower the risk of cavernosal fibrosis or decrease the severity the fibrosis in ED patients.

  2. Pin Wire Coating Trip Report

    International Nuclear Information System (INIS)

    Spellman, G P

    2004-01-01

    A meeting to discuss the current pin wire coating problems was held at the Reynolds plant in Los Angeles on 2MAR04. The attendance list for Reynolds personnel is attached. there was an initial presentation which gave a brief history and the current status of pin wire coating at Reynolds. There was a presentation by Lori Primus on the requirements and issues for the coating. There was a presentation by Jim Smith of LANL on the chemistry and to some extent process development done to date. There was a long session covering what steps should be taken in the short term and, to a lesser extent, the long term. The coating currently being used is a blend of two polymers, polyethersulfone and polyparabanic acid (PPA) and some TiO2 filler. This system was accepted and put into production when the pin wire coating was outsourced to another company in 1974. When that company no longer was interested, the wire coating was brought in-house to Reynolds. At that time polyparabanic acid was actually a commercial product available from Exxon under the trade name Tradlon. However, it appears that the material used at Reynolds was synthesized locally. Also, it appears that a single large batch was synthesized in that time period and used up to 1997 when the supply ran out. The reason for the inclusion of TiO2 is not known although it does act as a rheological thickener. However, a more controlled thickening can be obtained with materials such as fumed silica. This material would have less likelihood of causing point imperfections in the coatings. Also, the mixing technique being used for all stages of the process is a relatively low shear ball mill process and the author recommends a high shear process such as a three roll paint mill, at least for the final mixing. Since solvent is added to the powder at Reynolds, it may be that they need to have the paint mill there

  3. Cryogenic Pressure Seal for Wires

    Science.gov (United States)

    Ciana, J. J.

    1984-01-01

    High-pressure-seal formed by forcing polyurethane into space surrounding wire or cable in special fitting. Wire or cable routed through fitting then through a tightly fitting cap. Wire insulation left intact. Cap filled with sealant and forced onto the fitting: this pushes sealant into fitting so it seals wire or cable in fitting as well as in cap.

  4. Distribution of respiratory viruses which cause lower respiratory tract infection in pediatric age group

    Directory of Open Access Journals (Sweden)

    Selim Dereci

    2015-07-01

    Full Text Available Objective: To determine the appropriate treatment regimen and the clinical course of the lower respiratory tract infections( RTI s and to detect the common viral causes of lower RTI s. Methods: The present study included a total of 255 pediatric patients aged less than 7 years old and admitted to the Department of Pediatrics of Rize Training and Research Hospital between January 2014 and January 2015 with clinical pre-diagnosis of lower RTI . Nasopharyngeal swab specimens collected from these patients were tested for viral pathogens by using multiplex RT- PCR kit the ResPlex II plus Panel PRE (Qiagen, Germany. Results: A total of 212 out of 255 (83.1% specimens revealed positive for one or more viral pathogens. The most common detected pathogens were respiratory syncytial virus ( RSV A/B in 110 samples (43.1%, rhinovirus in 51 samples (20.0%, adenovirus in 36 samples (14.1%, influenzae virus A in 32 samples (12.5%, and coronavirus in 24 samples (9.4%. In 76 samples (29.8%, more than one viral pathogen were detected. RSV was seen in more than 50% patients in the first 2 years. RSV was the most common pathogen in each year of the first 5 years but rhinovirus, influenza A and adenovirus were seen more than RSV after the fifth year. A total of 95.8% of the viral detections were seen between November and April without a significant peak amongst these months. The distribution of the pathogens by months of the year showed no significance. Conclusions: These findings can contribute to epidemiological data of Turkey. Detection of the viral pathogens causing lower RTIs can be critical in management of the disease, decrease inappropriate antibiotic treatment, and lower the morbidity and mortality rates in such diseases.

  5. Global, regional, and national age-sex specific all-cause and cause-specific mortality for 240 causes of death, 1990-2013 : a systematic analysis for the Global Burden of Disease Study 2013

    NARCIS (Netherlands)

    Naghavi, Mohsen; Wang, Haidong; Lozano, Rafael; Davis, Adrian; Liang, Xiaofeng; Zhou, Maigeng; Vollset, Stein Emil; Ozgoren, Ayse Abbasoglu; Abdalla, Safa; Abd-Allah, Foad; Aziz, Muna I. Abdel; Abera, Semaw Ferede; Aboyans, Victor; Abraham, Biju; Abraham, Jerry P.; Abuabara, Katrina E.; Abubakar, Ibrahim; Abu-Raddad, Laith J.; Abu-Rmeileh, Niveen M. E.; Achoki, Tom; Adelekan, Ademola; Ademi, Zanfi Na; Adofo, Koranteng; Adou, Arsene Kouablan; Adsuar, Jose C.; Aernlov, Johan; Agardh, Emilie Elisabet; Akena, Dickens; Al Khabouri, Mazin J.; Alasfoor, Deena; Albittar, Mohammed; Alegretti, Miguel Angel; Aleman, Alicia V.; Alemu, Zewdie Aderaw; Alfonso-Cristancho, Rafael; Alhabib, Samia; Ali, Mohammed K.; Ali, Raghib; Alla, Francois; Al Lami, Faris; Allebeck, Peter; AlMazroa, Mohammad A.; Salman, Rustam Al-Shahi; Alsharif, Ubai; Alvarez, Elena; Alviz-Guzman, Nelson; Amankwaa, Adansi A.; Amare, Azmeraw T.; Ameli, Omid; Hoek, Hans W.

    2015-01-01

    Background Up-to-date evidence on levels and trends for age-sex-specifi c all-cause and cause-specifi c mortality is essential for the formation of global, regional, and national health policies. In the Global Burden of Disease Study 2013 (GBD 2013) we estimated yearly deaths for 188 countries

  6. Gestational age at birth and risk of intellectual disability without a common genetic cause.

    Science.gov (United States)

    Heuvelman, Hein; Abel, Kathryn; Wicks, Susanne; Gardner, Renee; Johnstone, Edward; Lee, Brian; Magnusson, Cecilia; Dalman, Christina; Rai, Dheeraj

    2017-12-06

    Preterm birth is linked to intellectual disability and there is evidence to suggest post-term birth may also incur risk. However, these associations have not yet been investigated in the absence of common genetic causes of intellectual disability, where risk associated with late delivery may be preventable. We therefore aimed to examine risk of intellectual disability without a common genetic cause across the entire range of gestation, using a matched-sibling design to account for unmeasured confounding by shared familial factors. We conducted a population-based retrospective study using data from the Stockholm Youth Cohort (n = 499,621) and examined associations in a nested cohort of matched outcome-discordant siblings (n = 8034). Risk of intellectual disability was greatest among those born extremely early (adjusted OR 24 weeks  = 14.54 [95% CI 11.46-18.44]), lessening with advancing gestational age toward term (aOR 32 weeks  = 3.59 [3.22-4.01]; aOR 37 weeks  = 1.50 [1.38-1.63]); aOR 38 weeks  = 1.26 [1.16-1.37]; aOR 39 weeks = 1.10 [1.04-1.17]) and increasing with advancing gestational age post-term (aOR 42 weeks  = 1.16 [1.08-1.25]; aOR 43 weeks  = 1.41 [1.21-1.64]; aOR 44 weeks  = 1.71 [1.34-2.18]; aOR 45 weeks  = 2.07 [1.47-2.92]). Associations persisted in a cohort of matched siblings suggesting they were robust against confounding by shared familial traits. Risk of intellectual disability was greatest among children showing evidence of fetal growth restriction, especially when birth occurred before or after term. Birth at non-optimal gestational duration may be linked causally with greater risk of intellectual disability. The mechanisms underlying these associations need to be elucidated as they are relevant to clinical practice concerning elective delivery around term and mitigation of risk in post-term children.

  7. A KCNQ1 mutation causes age-dependant bradycardia and persistent atrial fibrillation.

    Science.gov (United States)

    Ki, Chang-Seok; Jung, Chae Lim; Kim, Hyun-ji; Baek, Kwan-Hyuck; Park, Seung Jung; On, Young Keun; Kim, Ki-Suk; Noh, Su Jin; Youm, Jae Boum; Kim, June Soo; Cho, Hana

    2014-03-01

    Atrial fibrillation (AF) is the most common arrhythmia. Gain-of-function mutations in KCNQ1, the pore-forming α-subunit of the slow delayed rectifier K current (IKs) channel, have been associated with AF. The purpose of this study was functional assessment of a mutation in KCNQ1 identified in a family with persistent AF and sinus bradycardia. We investigated whether this KCNQ1 missense mutation could form the genetic basis for AF and bradycardia simultaneously in this family. Sanger sequencing in a family with hereditary persistent AF identified a novel KCNQ1 variant (V241F) in a highly conserved region of S4 domain. The proband and her son developed bradycardia and persistent AF in an age-dependent fashion. The other son was a mutation carrier but he showed sinus bradycardia and not AF. Whole-cell patch clamp electrophysiology showed that V241F mutation in KCNQ1 shifted the activation curve to the left and dramatically slowed deactivation, leading to a constitutively open-like phenotype. Computer modeling showed that V241F would slow pacemaker activity. Also, simulations of atrial excitation predicted that V241F results in extreme shortening of action potential duration, possibly resulting in AF. Our study indicates that V241F might cause sinus bradycardia by increasing IKs. Additionally, V241F likely shortens atrial refractoriness to promote a substrate for reentry. KCNQ1 mutations have previously been described in AF, yet this is the first time a mutation in KCNQ1 is associated with age-dependent bradycardia and persistent AF. This finding further supports the hypothesis that sinus node dysfunction contributes to the development of AF.

  8. Cholesterol-enriched diet causes age-related macular degeneration-like pathology in rabbit retina

    Directory of Open Access Journals (Sweden)

    Singh Brij B

    2011-08-01

    Full Text Available Abstract Background Alzheimer's disease (AD and age-related macular degeneration (AMD share several pathological hallmarks including β-amyloid (Aβ accumulation, oxidative stress, and apoptotic cell death. The causes of AD and AMD are likely multi-factorial with several factors such as diet, environment, and genetic susceptibility participating in the pathogenesis of these diseases. Epidemiological studies correlated high plasma cholesterol levels with high incidence of AD, and feeding rabbits with a diet rich in cholesterol has been shown to induce AD-like pathology in rabbit brain. High intake of cholesterol and saturated fat were also long been suspected to increase the risk for AMD. However, the extent to which cholesterol-enriched diet may also cause AMD-like features in rabbit retinas is not well known. Methods Male New Zealand white rabbits were fed normal chow or a 2% cholesterol-enriched diet for 12 weeks. At necropsy, animals were perfused with Dulbecco's phosphate-buffered saline and the eyes were promptly removed. One eye of each animal was used for immunohistochemistry and retina dissected from the other eye was used for Western blot, ELISA assays, spectrophotometry and mass spectrometry analyses. Results Increased levels of Aβ, decreased levels of the anti-apoptotic protein Bcl-2, increased levels of the pro-apoptotic Bax and gadd153 proteins, emergence of TUNEL-positive cells, and increased generation of reactive oxygen species were found in retinas from cholesterol-fed compared to normal chow-fed rabbits. Additionally, astrogliosis, drusen-like debris and cholesterol accumulations in retinas from cholesterol-fed rabbits were observed. As several lines of evidence suggest that oxidized cholesterol metabolites (oxysterols may be the link by which cholesterol contributes to the pathogenesis of AMD, we determined levels of oxysterols and found a dramatic increase in levels of oxysterols in retinas from cholesterol-fed rabbits

  9. Copper wire bonding

    CERN Document Server

    Chauhan, Preeti S; Zhong, ZhaoWei; Pecht, Michael G

    2014-01-01

    This critical volume provides an in-depth presentation of copper wire bonding technologies, processes and equipment, along with the economic benefits and risks.  Due to the increasing cost of materials used to make electronic components, the electronics industry has been rapidly moving from high cost gold to significantly lower cost copper as a wire bonding material.  However, copper wire bonding has several process and reliability concerns due to its material properties.  Copper Wire Bonding book lays out the challenges involved in replacing gold with copper as a wire bond material, and includes the bonding process changes—bond force, electric flame off, current and ultrasonic energy optimization, and bonding tools and equipment changes for first and second bond formation.  In addition, the bond–pad metallurgies and the use of bare and palladium-coated copper wires on aluminum are presented, and gold, nickel and palladium surface finishes are discussed.  The book also discusses best practices and re...

  10. Age-related processing delay reveals cause of apparent sensory excitability following auditory stimulation.

    Science.gov (United States)

    Volosin, Márta; Gaál, Zsófia Anna; Horváth, János

    2017-08-31

    When background auditory events lead to enhanced auditory event-related potentials (ERPs) for closely following sounds, this is generally interpreted as a transient increase in the responsiveness of the auditory system. We measured ERPs elicited by irrelevant probes (gaps in a continuous tone) at several time-points following rare auditory events (pitch glides) in younger and older adults, who watched movies during stimulation. Fitting previous results, in younger adults, gaps elicited increasing N1 auditory ERPs with decreasing glide-gap separation. N1 increase was paralleled by an ERP decrease in the P2 interval. In older adults, only a glide-gap separation dependent P2 decrease, but no N1-effect was observable. This ERP pattern was likely caused by a fronto-central negative waveform, which was delayed in the older adult group, thus overlapping N1 and P2 in the younger, but overlapping only P2 in the older adult group. Because the waveform exhibited a polarity reversal at the mastoids, it was identified as a mismatch negativity (MMN). This interpretation also fits previous studies showing that gap-related MMN is delayed in older adults, reflecting an age-related deterioration of fine temporal auditory resolution. These results provide a plausible alternative explanation for the ERP enhancement for sounds following background auditory events.

  11. Prevalence of Preventable Causes of Low Vision in Different Ages and Genders

    Directory of Open Access Journals (Sweden)

    Mohsen Akhgary

    2014-01-01

    Full Text Available Background: Much of the vision loss from age-related eye disease can be prevented. The purpose of this study is to determine 5Tthe prevalence5T 5Tof preventable5T 5Tcauses5T 5Tof low5T 5Tvision. Materials and Methods: In this study, files of 204 patients were evaluated5T.5T Low vision was defined as best-corrected visual acuity in the better eye between 20/70 to 20/200. Diagnosis of anterior and posterior segment disease was based on the eye examination that performed with Topcon slit-lamp biomicroscope and direct and indirect ophthalmoscope examination7T. Results: The prevalence of 5Tpreventable5T 5Tcauses of5T 5Tlow 5Twas respectively:5T diabetic retinopathy,5T 5Tin 335T 5Tpatients (5T16.18%, 5Tglaucoma 5Tin 6 5Tpatients (5T2.94%, 5Tand amblyopia5T in 5T2 patients (1%5T. Conclusion: The majority of cases have treatable and/or preventable causes; reduction of low vision or blindness can be achieved by appropriate screening strategies.

  12. Falls in young, middle-aged and older community dwelling adults: perceived cause, environmental factors and injury

    Directory of Open Access Journals (Sweden)

    Metter E Jeffery

    2005-08-01

    Full Text Available Abstract Background Falls in older people have been characterized extensively in the literature, however little has been reported regarding falls in middle-aged and younger adults. The objective of this paper is to describe the perceived cause, environmental influences and resultant injuries of falls in 1497 young (20–45 years, middle-aged (46–65 years and older (> 65 years men and women from the Baltimore Longitudinal Study on Aging. Methods A descriptive study where participants completed a fall history questionnaire describing the circumstances surrounding falls in the previous two years. Results The reporting of falls increased with age from 18% in young, to 21% in middle-aged and 35% in older adults, with higher rates in women than men. Ambulation was cited as the cause of the fall most frequently in all gender and age groups. Our population reported a higher percentage of injuries (70.5% than previous studies. The young group reported injuries most frequently to wrist/hand, knees and ankles; the middle-aged to their knees and the older group to their head and knees. Women reported a higher percentage of injuries in all age groups. Conclusion This is the first study to compare falls in young, middle and older aged men and women. Significant differences were found between the three age groups with respect to number of falls, activities engaged in prior to falling, perceived causes of the fall and where they fell.

  13. Elastic anisotropy in multifilament Nb$_3$Sn superconducting wires

    CERN Document Server

    Scheuerlein, C; Alknes, P; Arnau, G; Bjoerstad, R; Bordini, B

    2015-01-01

    The elastic anisotropy caused by the texture in the Nb3Sn filaments of PIT and RRP wires has been calculated by averaging the estimates of Voigt and Reuss, using published Nb3Sn single crystal elastic constants and the Nb3Sn grain orientation distribution determined in both wire types by Electron Backscatter Diffraction. At ambient temperature the calculated Nb3Sn E-moduli in axial direction in the PIT and the RRP wire are 130 GPa and 140 GPa, respectively. The calculated E-moduli are compared with tensile test results obtained for the corresponding wires and extracted filament bundles.

  14. Occupational class inequalities in all-cause and cause-specific mortality among middle-aged men in 14 European populations during the early 2000s.

    Directory of Open Access Journals (Sweden)

    Marlen Toch-Marquardt

    Full Text Available This study analyses occupational class inequalities in all-cause mortality and four specific causes of death among men, in Europe in the early 2000s, and is the most extensive comparative analysis of occupational class inequalities in mortality in Europe so far. Longitudinal data, obtained from population censuses and mortality registries in 14 European populations, from around the period 2000-2005, were used. Analyses concerned men aged 30-59 years and included all-cause mortality and mortality from all cancers, all cardiovascular diseases (CVD, all external, and all other causes. Occupational class was analysed according to five categories: upper and lower non-manual workers, skilled and unskilled manual workers, and farmers and self-employed combined. Inequalities were quantified with mortality rate ratios, rate differences, and population attributable fractions (PAF. Relative and absolute inequalities in all-cause mortality were more pronounced in Finland, Denmark, France, and Lithuania than in other populations, and the same countries (except France also had the highest PAF values for all-cause mortality. The main contributing causes to these larger inequalities differed strongly between countries (e.g., cancer in France, all other causes in Denmark. Relative and absolute inequalities in CVD mortality were markedly lower in Southern European populations. We conclude that relative and absolute occupational class differences in all-cause and cause specific mortality have persisted into the early 2000's, although the magnitude differs strongly between populations. Comparisons with previous studies suggest that the relative gap in mortality between occupational classes has further widened in some Northern and Western European populations.

  15. Modeling of Service-Drop Wires and Interior-Wiring Cables for Lightning Overvoltage Studies

    Science.gov (United States)

    Matsuura, Susumu; Noda, Taku; Nakamura, Masatoshi; Sakai, Hiroshi

    As the information society progresses, a variety of electronic appliances have come into wide use in common houses. If a lightning stroke causes faults or incorrect operations of these electronic appliances, a social economic loss is considered to be large. For this reason, the focus of lightning protection measures for distribution lines in Japan has expanded to include the low-voltage side of the distribution line in addition to the high-voltage side. In order to calculate lightning overvoltages at the low-voltage side, the surge characteristics of service-drop wires and interior-wiring cables have to be modeled accurately. First, this paper describes test results of the surge characteristics of service-drop wires and interior-wiring cables. The modal surge impedances and the propagation velocities of various service-drop wires and interior-wiring cables are obtained by the test. Based on the test results obtained, this paper proposes a modeling methodology of these wires and cables for accurate EMTP (Electro-Magnetic Transients Program) lightning overvoltage simulations. The proposed model is validated by comparing EMTP simulation results with field test results.

  16. Falls in old age: pills, the heart and beyond: Withdrawal of drugs and screening for cardiovascular causes in older fallers

    NARCIS (Netherlands)

    N. van der Velde (Nathalie)

    2007-01-01

    textabstractFall incidents are common in old age, with a rising injury rate with increasing age. Falling is not a diagnosis per se, but a symptom that can result from a number of diseases and abnormalities. However, even though there are abundant studies addressing possible causes of fall

  17. Age-specific prevalence and causes of blindness and visual impairment in an older population: the Rotterdam Study

    NARCIS (Netherlands)

    Klaver, C. C.; Wolfs, R. C.; Vingerling, J. R.; Hofman, A.; de Jong, P. T.

    1998-01-01

    To study the prevalence and causes of blindness and visual impairment in various age categories of a large population-based study. For the study, 6775 subjects aged 55 years or older underwent an extensive ophthalmologic screening examination, including measurements of visual acuity and the visual

  18. Crewmember repairing the Regenerative Carbon Dioxide Removal System wiring.

    Science.gov (United States)

    1992-01-01

    Mission Pilot Ken Bowersox, busy at work on the wiring harness for the Regenerative Carbon Dioxide Removal System located under the mid deck floor. Photo shows Bowersox splicing wires together to 'fool' a faulty sensor that caused the 'air conditioner' to shut down.

  19. Incidence of various causes of vaginal discharge among sexually active females in age group 20-40 years

    Directory of Open Access Journals (Sweden)

    Puri K

    2003-03-01

    Full Text Available The present study was undertaken to know incidence of various causes of vaginal discharge in sexually active females of age group 20-40 years. One hundred sexually active females in the age group of 20-40 years, with vaginal discharge, were selected for this study at random. A detailed clinical history and a thorough examination of all the cases was done. After making the clinical diagnosis, appropriate tests for diagnosing candidiasis, trichomoniosis, gonorrhoea and bacterial vaginosis were done. The present study showed 45% incidence of bacterial voginosis, 31% vulvovaginalcandidiasis, 2% trichomoniasis, 3% gonorrhoea, 5% non-specific urogenital causes, and 14% with other causes.

  20. WIRELESS TENSION BAND WIRING FOR OLECRANON FRACTURES. Case Series.

    Science.gov (United States)

    Roukoz, Sami; Bayoud, Wael

    2016-01-01

    This retrospective study evaluates the results of wireless tension band wire (WTBW) which is a modified technique of tension band wires (TBW) for Mayo type II A and III A olecranon fractures. In this technique the K-wires of the TBW are replaced by a cerclage wire while keeping the figure of eight wiring. We reviewed retrospectively our WTBW cases done between 2000 and 2015 where we replaced the K-wires by a cerclage wire. In this technique no hardware migration is possible. Patients were evaluated clinically, radiographicaly and a DASH score was measured. Seventeen patients were reviewed with a mean age of 58.5 years. The mean follow-up period was 58.5 months. The mean DASH score was 12 with 7 patients having a DASH score of zero. Joint mobility was near normal compared to the other side with loss of a mean of 4º in elbow extension and a mean of 3º in elbow flexion. In comparison with other series, in addition to good results, hardware removal for medical reasons was the lowest in our technique. It was needed in three patients for pain on elbow contact and in one with ulnar nerve irritation. This represents a rate of 23.5%. Undesirable events related to the use of K-wires in standard tension band wiring, such as wire migration, wire protrusion through the skin and wire impingement, are absent in the wireless tension band wiring. The high rate of patient satisfaction, good clinical results as well as low rate of needed hardware removal make this technique preferable for fixing Mayo Type II A olecranon fractures.

  1. Age and cause mortality structure in the Italian regions at the beginning of the health transition: a research

    Directory of Open Access Journals (Sweden)

    Lorenzo Del Panta

    2013-05-01

    Full Text Available This paper aims at exploring Italian mortality structure (by age and cause of death at the regional level in the last decades of the 19th Century. These years, corresponding to the beginning of the health transition process, were crucial in the Italian experience. The analysis is based on a careful exploitation of the volume “Statistica delle cause delle morti 1888”, published in 1890, by the General Directorate of Statistics. This volume is the only one which offers for the Italian regions, before the second World war, death statistics classified according to both age and cause together. The principal objectives of this descriptive contribution are essentially to illustrate the territorial variation of mortality conditions in the first phase of the health transition process as well as to underline the relevance and the complexities of the causes specific mortality analysis to explain the geographical mortality differentials in terms of age and sex.

  2. Research regarding wires elastic deformations influence on joints positioning of a wire-driven robotic arm

    Science.gov (United States)

    Ciofu, C.; Stan, G.

    2016-08-01

    In this paper, we present the influence of driving wires deformation on positioning precision of joints from an elephant's trunk robotic arm. Robotic arms driven by wires have the joint accuracy largely depending on wires rigidity. The joint moment of resistance causes elastic deformation of wires and it is determined by: manipulated object load, weight loads previous to the analyzed joint and inherent resistance moment of joint. Static load analysis emphasizes the particular wires elastic deformation of each driven joint from an elephant's trunk robotic arm with five degrees of freedom. We consider the case of a constant manipulated load. Errors from each driving system of joints are not part of the closed loop system. Thus, precision positioning depends on wires elastic deformation which is about microns and causes angle deviation of joints about tens of minutes of sexagesimal degrees. The closer the joints to base arm the smaller positioning precision of joint. The obtained results are necessary for further compensation made by electronic corrections in the programming algorithm of the elephant's trunk robotic arm to improve accuracy.

  3. [The causes of death of the women of childbearing age at the hospitals of Sfax].

    Science.gov (United States)

    Djedidi Trabelsi, Jihen; Yaich Kammoun, Sourour; Abderraouf Karray, Mohamed; Feki, Habib; Kassis, Mondher; Damak, Jamel

    2011-10-01

    To study the principal causes of death of the women dead at an âge ranging between 15 and 49 years old and having been hospitalized in a public medical structures of the gouvernorat of Sfax. Retrospective study concerning all the included deaths between 1999 and 2007. The study was related to 728 deaths, which correspond to an average of 80.88 deaths FAR per year. Public highway accidents were the major cause of death (83 cases, 11.4 % of the causes of death) followed by the burns (37 cases, 5%) and the cerebral vascular accidents (31 cases, 4.25%). The classification of the causes of death according to groups of pathologies showed the prevalence of the cardio- vascular diseases (18.7%), the external causes of death (18.2%), cancers (11.6%) and the causes related to the pregnancy and the childbirth (8.5%). The maternal death rate was of 56.91 per 100000. The cause of maternal death was directly related to the pregnancy in 67.74 % of the cases. The immediate causes were prevailed by the hemorrhagic causes (27.5%). The death was avoidable in 48.83 % of the cases and the failures were related to the woman in 60% of the cases. The prevention of new practices of life (female nicotinism, obesity, bad food habits, lack of vigilance in traffic) and a better practice of the primary and secondary prevention in medicine could decrease the premature death rates in Tunisia.

  4. Wired to freedom

    DEFF Research Database (Denmark)

    Jepsen, Kim Sune Karrasch; Bertilsson, Margareta

    2017-01-01

    dimension of life science through a notion of public politics adopted from the political theory of John Dewey. We show how cochlear implantation engages different social imaginaries on the collective and individual levels and we suggest that users share an imaginary of being “wired to freedom” that involves...... new access to social life, continuous communicative challenges, common practices, and experiences. In looking at their lives as “wired to freedom,” we hope to promote a wider spectrum of civic participation in the benefit of future life science developments within and beyond the field of Cochlear...

  5. Wiring and lighting

    CERN Document Server

    Kitcher, Chris

    2013-01-01

    Wiring and Lighting provides a comprehensive guide to DIY wiring around the home. It sets out the regulations and legal requirements surrounding electrical installation work, giving clear guidelines that will enable the reader to understand what electrical work they are able to carry out, and what the testing and certification requirements are once the work is completed. Topics covered include: Different types of circuits; Types of cables and cable installation under floors and through joists; Isolating, earthing and bonding; Accessory boxes and fixings; Voltage bands; Detailed advice on safe

  6. Electric wiring domestic

    CERN Document Server

    Coker, A J

    1992-01-01

    Electric Wiring: Domestic, Tenth Edition, is a clear and reliable guide to the practical aspects of domestic electric wiring. Intended for electrical contractors, installation engineers, wiremen and students, its aim is to provide essential up to date information on modern methods and materials in a simple, clear, and concise manner. The main changes in this edition are those necessary to bring the work into line with the 16th Edition of the Regulations for Electrical Installations issued by the Institution of Electrical Engineers. The book begins by introducing the basic features of domestic

  7. Modern wiring practice

    CERN Document Server

    Steward, W E

    2012-01-01

    Continuously in print since 1952, Modern Wiring Practice has now been fully revised to provide an up-to-date source of reference to building services design and installation in the 21st century. This compact and practical guide addresses wiring systems design and electrical installation together in one volume, creating a comprehensive overview of the whole process for contractors and architects, as well as electricians and other installation engineers. Best practice is incorporated throughout, combining theory and practice with clear and accessible explanation, all

  8. Metallurgical investigation of wire breakage of tyre bead grade

    Directory of Open Access Journals (Sweden)

    Piyas Palit

    2015-10-01

    Full Text Available Tyre bead grade wire is used for tyre making application. The wire is used as reinforcement inside the polymer of tyre. The wire is available in different size/section such as 1.6–0.80 mm thin Cu coated wire. During tyre making operation at tyre manufacturer company, wire failed frequently. In this present study, different broken/defective wire samples were collected from wire mill for detailed investigation of the defect. The natures of the defects were localized and similar in nature. The fracture surface was of finger nail type. Crow feet like defects including button like surface abnormalities were also observed on the broken wire samples. The defect was studied at different directions under microscope. Different advanced metallographic techniques have been used for detail investigation. The analysis revealed that, white layer of surface martensite was formed and it caused the final breakage of wire. In this present study we have also discussed about the possible reason for the formation of such kind of surface martensite (hard-phase.

  9. Cause-Specific Mortality Among Patients With Psychosis : Disentangling the Effects of Age and Illness Duration

    NARCIS (Netherlands)

    Termorshuizen, Fabian; Wierdsma, Andre I.; Smeets, Hugo M.; Visser, Ellen; Drukker, Marjan; Nijman, Henk; Sytema, Sjoerd

    2013-01-01

    There is a large mortality gap between patients with a nonaffective psychotic disorder and those in the general population, is associated with both natural and nonnatural death causes. Objective: This study aims to assess whether mortality risks vary for different causes of death according to the

  10. Psychological stress exposure to aged mice causes abnormal feeding patterns with changes in the bout number.

    Science.gov (United States)

    Yamada, Chihiro; Mogami, Sachiko; Hattori, Tomohisa

    2017-11-09

    Stress responses are affected by aging. However, studies on stress-related changes in feeding patterns with aging subject are minimal. We investigated feeding patterns induced by two psychological stress models, revealing characteristics of stress-induced feeding patterns as "meal" and "bout" (defined as the minimum feeding behavior parameters) in aged mice. Feeding behaviors of C57BL/6J mice were monitored for 24 h by an automatic monitoring device. Novelty stress reduced the meal amount over the 24 h in both young and aged mice, but as a result of a time course study it was persistent in aged mice. In addition, the decreased bout number was more pronounced in aged mice than in young mice. The 24-h meal and bout parameters did not change in either the young or aged mice following water avoidance stress (WAS). However, the meal amount and bout number increased in aged mice for 0-6 h after WAS exposure but remained unchanged in young mice. Our findings suggest that changes in bout number may lead to abnormal stress-related feeding patterns and may be one tool for evaluating eating abnormality in aged mice.

  11. Postnatal early overnutrition causes long-term renal decline in aging male rats.

    Science.gov (United States)

    Yim, Hyung Eun; Yoo, Kee Hwan; Bae, In Sun; Hong, Young Sook; Lee, Joo Won

    2014-02-01

    We evaluated the influence of postnatal early overnutrition on renal pathophysiological changes in aging rats. Three or 10 male pups per mother were assigned to either the small litter (SL) or normal litter (control) groups, respectively, during the first 21 d of life. The effects of early postnatal overnutrition were determined at 12 mo. SL rats weighed more than controls between 4 d and 6 mo of age (P renal cortex were higher in SL rats (P aging SL rats (P aging kidney and can lead to systolic hypertension with reduced intrarenal renin activity.

  12. The wire array Z pinch programme at Imperial College

    International Nuclear Information System (INIS)

    Haines, M.G.; Lebedev, S.V.; Chittenden, J.P.; Bland, S.N.; Beg, F.N.; Dangor, A.E.; Pikuz, S.A.; Shelkovenko, T.A.

    2001-01-01

    Plasma formation and implosion dynamics of wire array z-pinches have been studied experimentally using the MAGPIE generator (1.4MA, 240ns) at Imperial College. Simulations and theory verify much of the data. Both laser probing and x-ray radiography show after an initial volumetric heating of the wires the presence of dense wire cores surrounded by low density coronal plasma. Radiography shows development of perturbations on the dense core of each wire, while laser probing shows inward jetting of the coronal plasma caused by the global JxB force, and these plasma streams are axially non-uniform on the same spatial scale as later seen in the wire cores. The spatial scale of these perturbations (∼0.5mm for Al, ∼0.25mm for W) increases with the size of the wire cores (∼0.25mm for Al, ∼0.1mm for W). The inward flow of the coronal plasma is usually field free and leads to formation on the array axis of a straight plasma column, the dynamics of which is strongly affected by radiation cooling. Images obtained by optical streak camera show that the wire cores start their inward motion late and the implosion trajectory deviates significantly from the expected from 0-D analysis. An increase of the number of wires (decrease of inter-wire gap) resulted in a transition to 0-D trajectory for aluminium wire arrays, but not for tungsten. In experiments with nested wire arrays two modes of behaviour are observed; in the first the inner array is transparent to the imploding outer array, but the current transfers to it, leading to a fast implosion. The second mode occurs when a significant fraction of current is flowing in the inner array and the two arrays apparently implode simultaneously. In both modes the x-ray pulse is significantly sharpened in comparison with that generated in implosion of a single wire array. (author)

  13. Global, regional, and national age-sex specific mortality for 264 causes of death, 1980–2016

    DEFF Research Database (Denmark)

    Moesgaard Iburg, Kim

    2017-01-01

    (CODEm) to generate estimates for each location, year, age, and sex. We assessed observed and expected levels and trends of cause-specific deaths in relation to the Socio-demographic Index (SDI), a summary indicator derived from measures of average income per capita, educational attainment, and total......Background Monitoring levels and trends in premature mortality is crucial to understanding how societies can address prominent sources of early death. The Global Burden of Disease 2016 Study (GBD 2016) provides a comprehensive assessment of cause-specific mortality for 264 causes in 195 locations...... from 1980 to 2016. This assessment includes evaluation of the expected epidemiological transition with changes in development and where local patterns deviate from these trends. Methods We estimated cause-specific deaths and years of life lost (YLLs) by age, sex, geography, and year. YLLs were...

  14. Frailty Index Predicts All-Cause Mortality for Middle-Aged and Older Taiwanese: Implications for Active-Aging Programs.

    Science.gov (United States)

    Lin, Shu-Yu; Lee, Wei-Ju; Chou, Ming-Yueh; Peng, Li-Ning; Chiou, Shu-Ti; Chen, Liang-Kung

    2016-01-01

    Frailty Index, defined as an individual's accumulated proportion of listed health-related deficits, is a well-established metric used to assess the health status of old adults; however, it has not yet been developed in Taiwan, and its local related structure factors remain unclear. The objectives were to construct a Taiwan Frailty Index to predict mortality risk, and to explore the structure of its factors. Analytic data on 1,284 participants aged 53 and older were excerpted from the Social Environment and Biomarkers of Aging Study (2006), in Taiwan. A consensus workgroup of geriatricians selected 159 items according to the standard procedure for creating a Frailty Index. Cox proportional hazard modeling was used to explore the association between the Taiwan Frailty Index and mortality. Exploratory factor analysis was used to identify structure factors and produce a shorter version-the Taiwan Frailty Index Short-Form. During an average follow-up of 4.3 ± 0.8 years, 140 (11%) subjects died. Compared to those in the lowest Taiwan Frailty Index tertile ( 0.23) had significantly higher risk of death (Hazard ratio: 3.2; 95% CI 1.9-5.4). Thirty-five items of five structure factors identified by exploratory factor analysis, included: physical activities, life satisfaction and financial status, health status, cognitive function, and stresses. Area under the receiver operating characteristic curves (C-statistics) of the Taiwan Frailty Index and its Short-Form were 0.80 and 0.78, respectively, with no statistically significant difference between them. Although both the Taiwan Frailty Index and Short-Form were associated with mortality, the Short-Form, which had similar accuracy in predicting mortality as the full Taiwan Frailty Index, would be more expedient in clinical practice and community settings to target frailty screening and intervention.

  15. Global and regional mortality from 235 causes of death for 20 age groups in 1990 and 2010

    DEFF Research Database (Denmark)

    Lozano, Rafael; Naghavi, Mohsen; Foreman, Kyle

    2012-01-01

    Reliable and timely information on the leading causes of death in populations, and how these are changing, is a crucial input into health policy debates. In the Global Burden of Diseases, Injuries, and Risk Factors Study 2010 (GBD 2010), we aimed to estimate annual deaths for the world and 21 reg...... regions between 1980 and 2010 for 235 causes, with uncertainty intervals (UIs), separately by age and sex....

  16. Percutaneous tension band wiring for patellar fractures.

    Science.gov (United States)

    Rathi, Akhilesh; Swamy, M K S; Prasantha, I; Consul, Ashu; Bansal, Abhishek; Bahl, Vibhu

    2012-08-01

    To evaluate outcome of percutaneous tension band wiring for transverse fractures of the patella. 16 men and 7 women aged 27 to 65 (mean, 40) years underwent percutaneous tension band wiring for transverse fractures of the patella with a displacement of >3 mm. Pain, operating time, mobility, functional score, and complications were evaluated. 20 patients underwent successful percutaneous tension band wiring. The remaining 3 patients in whom closed reduction failed underwent open reduction and tension band wiring. The mean operating time was 46 (range, 28-62) minutes. The mean follow-up period was 20 (range, 15-30) months. At the latest follow-up, all patients had regained full extension. The objective score was excellent in 20 patients and good in 3, whereas the subjective score was excellent in 17, good in 5, and fair in one. All patients had radiological union at week 8. One patient had patellofemoral arthritis (secondary to a postoperative articular step). Two patients developed superficial infections, which resolved after antibiotic therapy. Mean thigh muscle wasting was 0.7 (range, 0.4-1) cm. Three patients encountered hardware problems (impingement/irritation of the skin over the knee) necessitating implant removal. Percutaneous tension band wiring is a viable option for transverse fractures of the patella.

  17. Recent development of drastically innovative BSCCO wire (DI-BISCCO)

    International Nuclear Information System (INIS)

    Kikuchi, M.; Kato, T.; Ohkura, K.; Ayai, N.; Fujikami, J.; Fujino, K.; Kobayashi, S.; Ueno, E.; Yamazaki, K.; Yamade, S.; Hayashi, K.; Sato, K.; Nagai, T.; Matsui, Y.

    2006-01-01

    Up to this day, Ag-sheathed Bi2223 superconducting wires have been widely investigated and the long wires about 1000 m have been produced by using powder-in-tube (PIT) method on a commercial basis in the various facilities or companies. Although the wires are used for some applications such as HTS cables, magnets, motor and so on, the Bi2223 wires not only require much more improvements of the superconducting properties such as critical current, mechanical properties, but also longer and more uniform wires. Recently, the performances of Bi2223 wires have been drastically improved by using Controlled Over Pressure (CT-OP) sintering process. CT-OP process increased critical current (I c ) by more than 60% at 77 K and self field and improved the mechanical strength by more than 70%. The maximum I c was increased up to 166 A. These drastic improvements were caused by the higher density of Bi2223 filament up to almost 100% and better connectivity of the Bi2223 grains. The dense structure of the Bi2223 filaments prevents the ballooning phenomenon which is caused by the gasification of the trapped liquid nitrogen during temperature rise. Additionally, higher uniformity and higher production yield of long length wire were also achieved by exterminating defects during sintering. These high performance levels in CT-OP wires have contributed commercial level applications. We call as Drastically Innovative BSCCO (DI-BSCCO)

  18. Mitochondrial oxidative stress caused by Sod2 deficiency promotes cellular senescence and aging phenotypes in the skin.

    Science.gov (United States)

    Velarde, Michael C; Flynn, James M; Day, Nicholas U; Melov, Simon; Campisi, Judith

    2012-01-01

    Cellular senescence arrests the proliferation of mammalian cells at risk for neoplastic transformation, and is also associated with aging. However, the factors that cause cellular senescence during aging are unclear. Excessive reactive oxygen species (ROS) have been shown to cause cellular senescence in culture, and accumulated molecular damage due to mitochondrial ROS has long been thought to drive aging phenotypesin vivo. Here, we test the hypothesis that mitochondrial oxidative stress can promote cellular senescence in vivo and contribute to aging phenotypes in vivo, specifically in the skin. We show that the number of senescent cells, as well as impaired mitochondrial (complex II) activity increase in naturally aged mouse skin. Using a mouse model of genetic Sod2 deficiency, we show that failure to express this important mitochondrial anti-oxidant enzyme also impairs mitochondrial complex II activity, causes nuclear DNA damage, and induces cellular senescence but not apoptosis in the epidermis. Sod2 deficiency also reduced the number of cells and thickness of the epidermis, while increasing terminal differentiation. Our results support the idea that mitochondrial oxidative stress and cellular senescence contribute to aging skin phenotypes in vivo.

  19. Practical wiring in SI units

    CERN Document Server

    Miller, Henry A

    2013-01-01

    Practical Wiring, Volume 1 is a 13-chapter book that first describes some of the common hand tools used in connection with sheathed wiring. Subsequent chapters discuss the safety in wiring, cables, conductor terminations, insulating sheathed wiring, conductor sizes, and consumer's control equipments. Other chapters center on socket outlets, plugs, lighting subcircuits, lighting accessories, bells, and primary and secondary cells. This book will be very valuable to students involved in this field of interest.

  20. Wire EDM for Refractory Materials

    Science.gov (United States)

    Zellars, G. R.; Harris, F. E.; Lowell, C. E.; Pollman, W. M.; Rys, V. J.; Wills, R. J.

    1982-01-01

    In an attempt to reduce fabrication time and costs, Wire Electrical Discharge Machine (Wire EDM) method was investigated as tool for fabricating matched blade roots and disk slots. Eight high-strength nickel-base superalloys were used. Computer-controlled Wire EDM technique provided high quality surfaces with excellent dimensional tolerances. Wire EDM method offers potential for substantial reductions in fabrication costs for "hard to machine" alloys and electrically conductive materials in specific high-precision applications.

  1. Wire chambers: Trends and alternatives

    International Nuclear Information System (INIS)

    Regler, Meinhard

    1992-01-01

    The subtitle of this year's Vienna Wire Chamber Conference - 'Recent Trends and Alternative Techniques' - signalled that it covered a wide range of science and technology. While an opening Vienna talk by wire chamber pioneer Georges Charpak many years ago began 'Les funerailles des chambres a fils (the burial of wire chambers)', the contrary feeling this year was that wire chambers are very much alive!

  2. Transgenic expression of cyclooxygenase-2 (COX2) causes premature aging phenotypes in mice

    Science.gov (United States)

    Feng, Mingxiao; Field, Kevin; Chatzistamou, Ioulia; Shim, Minsub

    2016-01-01

    Cyclooxygenase (COX) is a key enzyme in the biosynthesis of prostanoids, lipid signaling molecules that regulate various physiological processes. COX2, one of the isoforms of COX, is highly inducible in response to a wide variety of cellular and environmental stresses. Increased COX2 expression is thought to play a role in the pathogenesis of many age-related diseases. COX2 expression is also reported to be increased in the tissues of aged humans and mice, which suggests the involvement of COX2 in the aging process. However, it is not clear whether the increased COX2 expression is causal to or a result of aging. We have now addressed this question by creating an inducible COX2 transgenic mouse model. Here we show that post-natal expression of COX2 led to a panel of aging-related phenotypes. The expression of p16, p53, and phospho-H2AX was increased in the tissues of COX2 transgenic mice. Additionally, adult mouse lung fibroblasts from COX2 transgenic mice exhibited increased expression of the senescence-associated β-galactosidase. Our study reveals that the increased COX2 expression has an impact on the aging process and suggests that modulation of COX2 and its downstream signaling may be an approach for intervention of age-related disorders. PMID:27750221

  3. Command Wire Sensor Measurements

    Science.gov (United States)

    2012-09-01

    CFAR Constant False Alarm Rate CWIE Command Wire-Improvised Explosive Device EMI Electromagnetic Induction GPR Ground Penetrating Radar...this, some type of constant false alarm rate ( CFAR ) receiver is required. CFAR automatically raises the threshold level to keep clutter echoes and

  4. Transport in quantum wires

    Indian Academy of Sciences (India)

    Transport in quantum wires. SIDDHARTHA LAL, SUMATHI RAO£ and DIPTIMAN SEN. Centre for Theoretical Studies, Indian Institute of Science, Bangalore 560 012, India. £ Harish-chandra Research Institute, Chhatnag Road, Jhusi, Allahabad 211 019, India. Abstract. With a brief introduction to one-dimensional channels ...

  5. Wire chamber conference

    International Nuclear Information System (INIS)

    Bartl, W.; Neuhofer, G.; Regler, M.

    1986-02-01

    This booklet contains program and the abstracts of the papers presented at the conference, most of them dealing with performance testing of various types of wire chambers. The publication of proceedings is planned as a special issue of 'Nuclear instruments and methods' later on. All abstracts are in English. An author index for the book of abstracts is given. (A.N.)

  6. Trends in All-Cause Mortality across Gestational Age in Days for Children Born at Term

    DEFF Research Database (Denmark)

    Wu, Chun Sen; Sun, Yuelian; Nohr, Ellen Aagaard

    2015-01-01

    BACKGROUND: Term birth is a gestational age from 259 days to 293 days. However trends in mortality according to gestational ages in days have not yet been described in this time period. METHODS AND FINDINGS: Based on nation-wide registries, we conducted a population-based cohort study among all...... children born at term in Denmark from 1997 to 2004 to estimate differences in mortality across gestational ages in days among singletons born at term. We studied early-neonatal mortality, neonatal mortality, infant mortality, and five-year mortality. Children were followed from birth up to the last day...

  7. Aging causes decreased resistance to multiple stresses and a failure to activate specific stress response pathways

    OpenAIRE

    Dues, Dylan J.; Andrews, Emily K.; Schaar, Claire E.; Bergsma, Alexis L.; Senchuk, Megan M.; Van Raamsdonk, Jeremy M.

    2016-01-01

    In this work, we examine the relationship between stress resistance and aging. We find that resistance to multiple types of stress peaks during early adulthood and then declines with age. To dissect the underlying mechanisms, we use C. elegans transcriptional reporter strains that measure the activation of different stress responses including: the heat shock response, mitochondrial unfolded protein response, endoplasmic reticulum unfolded protein response, hypoxia response, SKN-1-mediated oxi...

  8. Is Rising Obesity Causing a Secular (Age-Independent) Decline in Testosterone among American Men?

    OpenAIRE

    Mazur, Allan; Westerman, Ronny; Mueller, Ulrich

    2013-01-01

    The testosterone of men in industrial societies peaks in their twenties and tends to decline with increasing age. Apart from this individual-level decline, there have been reports of a secular (age-independent population-level) decline in testosterone among American and Scandinavian men during the past few decades, possibly an indication of declining male reproductive health. It has been suggested that both declines in testosterone (individual-level and population-level) are due to increasing...

  9. Balanced Caloric Restriction Minimizes Changes Caused by Aging on the Colonic Myenteric Plexus.

    Science.gov (United States)

    Mari, Renata de Britto; Stabille, Sandra Regina; de Faria, Haroldo Garcia; Pereira, Joice Naiara Bertaglia; Guimarães, Juliana Plácido; Marinsek, Gabriela Pustiglione; de Souza, Romeu Rodrigues

    2018-05-04

    Aging can promote significant morphofunctional changes in the gastrointestinal tract (GIT). Regulation of GIT motility is mainly controlled by the myenteric neurons of the enteric nervous system. Actions that aim at decreasing the aging effects in the GIT include those related to diet, with caloric restriction (CR). The CR is achieved by controlling the amount of food or by manipulating the components of the diet. Therefore, the objective of this study was to evaluate different levels of CR on the plasticity of nicotinamide adenine dinucleotide phosphate- (NADPH-) reactive myenteric neurons in the colon of Wistar rats during the aging process using ultrastructural (transmission electron microscopy) and morphoquantitative analysis. Wistar male rats (Rattus norvegicus) were distributed into 4 groups (n = 10/group): C, 6-month-old animals; SR, 18-month-old animals fed a normal diet; CRI, 18-month-old animals fed a 12% CR diet; CRII, 18-month-old animals fed a 31% CR diet. At 6 months of age, animals were transferred to the laboratory animal facility, where they remained until 18 months of age. Animals of the CRI and CRII groups were submitted to CR for 6 months. In the ultrastructural analysis, a disorganization of the periganglionar matrix with the aging was observed, and this characteristic was not observed in the animals that received hypocaloric diet. It was observed that the restriction of 12.5% and 31% of calories in the diet minimized the increase in density and cell profile of the reactive NADPH neurons, increased with age. This type of diet may be adapted against gastrointestinal disturbances that commonly affect aging individuals.

  10. The Impact of Gender, Family Type and Age on Undergraduate Parents' Perception of Causes of Sexual Abuse

    Science.gov (United States)

    Onoyase, Anna

    2016-01-01

    The purpose of this study was to investigate the Impact of Gender, Family type and Age on undergraduate parents' perception of causes of child Sexual Abuse. Three hypotheses were formulated and tested. There was a review of relevant literature. The population for the study were 2014 sandwich contact students of Delta State University, Abraka who…

  11. [The changing sex differences in life expectancy in Spain (1980-2012): decomposition by age and cause].

    Science.gov (United States)

    García González, Juan Manuel; Grande, Rafael

    To calculate and analyse the contributions of changes in mortality by age groups and selected causes of death to sex differences in life expectancy at birth in Spain from 1980 to 2012. Cross-sectional study with three time points (1980, 1995, and 2012). We used data from Human Cause-of-Death Database and Human Mortality Database. We use a decomposition method of the differences in life expectancy and gender differences in life expectancy from changes in mortality by 5-year age groups and causes of death between women and men. From 1980 to 1995, the lower mortality of women from 25 years old, and the differences in mortality by HIV/AIDS, lung cancer, and chronic obstructive pulmonary diseases contributed to the gap increase. From 1995 to 2012, greatest improvement in mortality of males under 74 years of age, and in improving male mortality from HIV/AIDS, acute myocardial infarction and traffic accidents contributed to the narrowing. The difference in life expectancy at birth between men and women has decreased since 1995 due to a greater improvement in mortality from causes of death associated with risky behaviours and habits of the working age male population. Copyright © 2017 SESPAS. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. [Influence of age on the presumed cause of syncope in patients with the Wolff-Parkinson-White syndrome].

    Science.gov (United States)

    Chometon, F; Brembilla-Perrot, B

    2007-01-01

    The aim of this study was to assess the causes of syncope in patients with the Wolff-Parkinson-White syndrome (WPW) and to determine whether the age of the patients was a significant factor. Forty-seven patients with a WPW, aged 11 to 72 years, underwent electrophysiological study by the oesophageal approach because of an unexplained syncope. Nineteen patients were under 20 years of age (16 +/- 3 years: group I) and 28 were over 20 years of age (40 +/- 13 years: group II). Junctional tachycardia was induced in 8 patients of group I (42%) and in 13 of group II (46%) (NS); atrial fibrillation was induced in 8 patients of group I (42%) and in 9 of group II (35%) (NS). A potentially malignant form of WPW was identified in 8 patients of group I (42%) and in 11 of group II (39%) (NS); Syncope was directly attributed to the WPW in 14 patients of group I (74%) and in 19 of group II (78%), either after identification of a serious form or induction of junctional tachycardia (6 patients of group I and 8 of group II). The rest of the syncopal episodes had various causes. There were no deaths. The authors conclude that oesophageal electrophysiological investigations enable rapid identification of a high incidence of tachycardias probably responsible for syncope in WPW. The causes of syncope and incidence of potentially severe forms of WPW were not significantly influenced by the age of the patients.

  13. Loss of renal function causes premature aging of the immune system.

    Science.gov (United States)

    Betjes, Michiel G H; Meijers, Ruud W J; Litjens, Nicolle H R

    2013-01-01

    Uremia-associated immune deficiency is a well-known complication of loss of renal function and contributes significantly to the overall mortality and morbidity of patients with end-stage renal disease. Chronic inflammation and increased oxidative stress are underlying the uremia-associated immune deficiency. In this review, the differential impact of uremia on the cellular immune system is summarized. Virtually all immune cells studied show a combination of an activated status and loss of function. However, uremia preferentially decreases the number and function of lymphoid cells while myeloid cells show normal and/or elevated cell numbers with increased production of inflammatory cytokines and reactive oxygen species. These particular changes are compatible with immunological aging, which is characterized by loss of thymic function, attrition of telomeres and an expanded memory T cell population. Similar to aging in healthy individuals, the proinflammatory and potential cardiotoxic subsets of CD28(null) T cells and CD16(+) monocytes are increased. Epigenetically changed hematopoietic stem cells may be involved in immunological aging as specific DNA regions become hypermethylated. Proinflammatory T cells and monocytes persist after kidney transplantation, which constitutes a persistent cardiovascular risk factor. Possible therapeutic options to reverse or halt uremia-associated immunological aging are discussed. Premature aging of the immune system is a dominant feature in patients with end-stage renal failure, which corresponds to immunological aging in elderly healthy individuals, which is characterized by preferential loss of cells belonging to the lymphoid cell lineage, inflammation and expansion of proinflammatory immune cells. © 2013 S. Karger AG, Basel.

  14. 'A confession of ignorance': deaths from old age and deciphering cause-of-death statistics in Scotland, 1855-1949.

    Science.gov (United States)

    Reid, Alice; Garrett, Eilidh; Dibben, Chris; Williamson, Lee

    2015-07-03

    A large amount of the research undertaken in an attempt to discover the reasons underlying the late nineteenth- and early twentieth-century mortality decline in Britain has relied on the statistics published by the Registrars General. The processes by which individual causes of death are recorded and then processed in order to create the statistics are not, however, well understood. In this article, the authors build on previous work to piece together a time series of causes of death for Scotland, which removes many of the discontinuities encountered in the published statistics that result from the Registrar General deciding to update the nosology, or classification system, which was being used to compile his figures. Having regrouped individual causes of death to 'smooth' the time series, the authors use the new groups to examine the changing causes of death in Scotland for selected age groups, before turning to undertake a detailed examination of mortality amongst those aged 55 or more. The authors find that when deaths from 'old age' in the latter age group are separated from other 'ill-defined' causes, it becomes obvious that there was a 'rebranding' of cause of death. The authors then use individual-level data from two Scottish communities to further dissect the roles played by 'informants' and 'doctors' in this rebranding, in order to see how these roles may have altered over time and what the consequences might be for one's view of how mortality changed in Scotland between 1855 and 1949. Finally, the authors argue that their findings have important implications for some of historical demography's most prominent theories: the McKeown thesis and the theory of epidemiological transition.

  15. Hierarchical structures in cold-drawn pearlitic steel wire

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2013-01-01

    The microstructure and crystallography of drawn pearlitic steel wires have been quantified by a number of electron microscopy techniques including scanning electron microscopy, transmission electron microscopy, electron backscatter diffraction and nanobeam diffraction, with focus on the change...... in the structure and crystallography when a randomly oriented cementite structure in a patented wire during wire drawing is transformed into a lamellar structure parallel to the drawing axis. Changes in the interlamellar spacing and in the misorientation angle along and across the ferrite lamellae show significant...... through-diameter variations in wires drawn to large strains P 1.5. The structural evolution is hierarchical as the structural variations have their cause in a different macroscopic orientation of the cementite in the initial (patented) structure with respect to the wire axis. The through...

  16. Is rising obesity causing a secular (age-independent) decline in testosterone among American men?

    Science.gov (United States)

    Mazur, Allan; Westerman, Ronny; Mueller, Ulrich

    2013-01-01

    The testosterone of men in industrial societies peaks in their twenties and tends to decline with increasing age. Apart from this individual-level decline, there have been reports of a secular (age-independent population-level) decline in testosterone among American and Scandinavian men during the past few decades, possibly an indication of declining male reproductive health. It has been suggested that both declines in testosterone (individual-level and population-level) are due to increasing male obesity because men in industrial society tend to add body fat as they age, and overall rates of obesity are increasing. Using an unusually large and lengthy longitudinal dataset (991 US Air Force veterans examined in six cycles over 20 years), we investigate the relationship of obesity to individual and population-level declines in testosterone. Over twenty years of study, longitudinal decline in mean testosterone was at least twice what would be expected from cross-sectional estimates of the aging decline. Men who put on weight intensified their testosterone decline, some greatly so, but even among those who held their weight constant or lost weight during the study, mean testosterone declined 117 ng/dl (19%) over 20 years. We have not identified the reason for secular decline in testosterone, but we exclude increasing obesity as a sufficient or primary explanation, and we deny the supposition that men who avoid excessive weight will maintain their youthful levels of testosterone.

  17. Trends in All-Cause Mortality across Gestational Age in Days for Children Born at Term

    Science.gov (United States)

    Wu, Chun Sen; Sun, Yuelian; Nohr, Ellen Aagaard; Olsen, Jørn

    2015-01-01

    Background Term birth is a gestational age from 259 days to 293 days. However trends in mortality according to gestational ages in days have not yet been described in this time period. Methods and Findings Based on nation-wide registries, we conducted a population-based cohort study among all children born at term in Denmark from 1997 to 2004 to estimate differences in mortality across gestational ages in days among singletons born at term. We studied early-neonatal mortality, neonatal mortality, infant mortality, and five-year mortality. Children were followed from birth up to the last day of the defined mortality period or December 31, 2009. A total of 360,375 singletons born between 259 and 293 days of gestation were included in the study. Mortality decreased with increasing gestational age in days and the highest mortality was observed among children born at 37 week of gestation. A similar pattern was observed when analyses were restricted to children born to by mothers without pregnancy complications. Conclusions This study demonstrates heterogeneity in mortality rates even among singletons born at term. The highest mortality was observed among children born 37 weeks of gestation, which call for cautions when inducing labor in term pregnancies just reaching 37 weeks of gestation. The findings support that 37 weeks of gestation should be defined as early term. PMID:26656842

  18. Is rising obesity causing a secular (age-independent decline in testosterone among American men?

    Directory of Open Access Journals (Sweden)

    Allan Mazur

    Full Text Available The testosterone of men in industrial societies peaks in their twenties and tends to decline with increasing age. Apart from this individual-level decline, there have been reports of a secular (age-independent population-level decline in testosterone among American and Scandinavian men during the past few decades, possibly an indication of declining male reproductive health. It has been suggested that both declines in testosterone (individual-level and population-level are due to increasing male obesity because men in industrial society tend to add body fat as they age, and overall rates of obesity are increasing. Using an unusually large and lengthy longitudinal dataset (991 US Air Force veterans examined in six cycles over 20 years, we investigate the relationship of obesity to individual and population-level declines in testosterone. Over twenty years of study, longitudinal decline in mean testosterone was at least twice what would be expected from cross-sectional estimates of the aging decline. Men who put on weight intensified their testosterone decline, some greatly so, but even among those who held their weight constant or lost weight during the study, mean testosterone declined 117 ng/dl (19% over 20 years. We have not identified the reason for secular decline in testosterone, but we exclude increasing obesity as a sufficient or primary explanation, and we deny the supposition that men who avoid excessive weight will maintain their youthful levels of testosterone.

  19. Causes and consequences of maternal age-related aneuploidy in oocytes: a review

    Czech Academy of Sciences Publication Activity Database

    Danylevska, Anna; Šebestová, Jaroslava

    2013-01-01

    Roč. 58, č. 2 (2013), s. 65-72 ISSN 0375-8427 R&D Projects: GA ČR GA523/09/0743; GA ČR GAP502/12/2201 Institutional support: RVO:67985904 Keywords : aneuploidy * oocyte * maternal age Subject RIV: EB - Genetics ; Molecular Biology Impact factor: 0.756, year: 2013

  20. Aging causes a reorganization of cortical and spinal control of posture

    NARCIS (Netherlands)

    Papegaaij, Selma; Taube, Wolfgang; Baudry, Stephane; Otten, Egbert; Hortobagyi, Tibor

    2014-01-01

    Classical studies in animal preparations suggest a strong role for spinal control of posture. In humans it is now established that the cerebral cortex contributes to postural control of unperturbed and perturbed standing. The age-related degeneration and accompanying functional changes in the brain,

  1. Aging causes a reorganization of cortical and spinal control of posture

    Directory of Open Access Journals (Sweden)

    Selma ePapegaaij

    2014-03-01

    Full Text Available Classical studies in animal preparations suggest a strong role for spinal control of posture. In young adults it is now established that the cerebral cortex contributes to postural control of unperturbed and perturbed standing. The age-related degeneration and accompanying functional changes in the brain, reported so far mainly in conjunction with simple manual motor tasks, may also affect the mechanisms that control complex motor tasks involving posture. This review outlines the age-related structural and functional changes at spinal and cortical levels and provides a mechanistic analysis of how such changes may be linked to the behaviorally manifest postural deficits in old adults. The emerging picture is that the age-related reorganization in motor control during voluntary tasks, characterized by differential modulation of spinal reflexes, greater cortical activation and cortical disinhibition, is also present during postural tasks. We discuss the possibility that this reorganization underlies the increased coactivation and dual task interference reported in elderly. Finally, we propose a model for future studies to unravel the structure-function-behavior relations in postural control and aging.

  2. Evaluation of the causes of neonatal jaundice, based on the infant’s age at disease onset and age at hospital admission

    Directory of Open Access Journals (Sweden)

    Hassan Boskabadi

    2016-01-01

    Full Text Available Background: Jaundice is the most common cause of neonatal admission within the first month after birth. Therefore, by identifying the causes of jaundice based on the infant’s age at disease onset and age at hospital admission and providing the required training, jaundice can be managed and its associated complications can be prevented. This study was performed to evaluate the causes of neonatal jaundice, based on the infant’s age at disease onset and age at hospital admission. Methods: In this cross-sectional study, out of 3,130 infants with jaundice, referring to Ghaem Hospital, Mashhad, Iran, from 2003 to 2015, 2,658 newborns were selected. Causes of jaundice are determined based on hematocrit, direct and indirect bilirubin, Coombs test, reticulocyte count, blood group and Rh of mother and neonate, thyroid tests, glucose-6-phosphate dehydrogenase (G6PD enzyme testing, urinalysis, urine culture, and If necessary, Na, blood urea nitrogen, creatinine and other tests depending on the doctor's supervision. After confirming jaundice in infants, based on the physician’s diagnosis and laboratory results, a researcher-made questionnaire including the infant’s characteristics, was completed. Results: Based on our study, 27.9% of infants had identified as causes of jaundice. Known causes of jaundice were blood group incompatibility (40%, infection (19%, G6PD enzyme deficiency (12%, endocrine disorders (8%, neonatal hypernatremic dehydration (7%, polycythemia (6%, congenital heart disease (CHD (4%, occult bleeding (3% and Crigler-Najjar syndrome (2%. The most common time of hospital admission of jaundice was 4-6 days after birth due to blood incompatibilities, occult bleeding, endocrine disorders, hypernatremic dehydration, CHD, polycythemia and G6PD enzyme deficiency. Moreover, the most common time of admission due to infection was after the first week of birth. Conclusion: The most common age of onset of jaundice was first three days of birth

  3. The effect of clamping a tensioned wire: implications for the Ilizarov external fixation system.

    Science.gov (United States)

    Watson, M A; Mathias, K J; Maffulli, N; Hukins, D W L

    2003-01-01

    This study demonstrates that clamping a tensioned wire can cause a reduction in wire tension. Tension (about 1275 N) was applied to a wire that was subsequently clamped, using cannulated bolts, to the steel half-ring of an Ilizarov external fixator. The tension in the wire was monitored before, during and after clamping. The apparatus was disassembled and the deformations in the wire caused by the clamps were measured. This experiment was repeated 15 times. When the wire was clamped to the frame, the wire tension was reduced by 22 +/- 7 per cent (mean +/- standard deviation, SD). The drop in wire tension was linearly correlated (r = 0.96; p toothpaste from a tube) and so reduce its tension during fixator assembly. To assess the magnitude of this effect in the clinical situation, the FE model analysis was repeated to replicate clamping a 1.8-mm-diameter wire to a 180-mm-diameter steel Ilizarov ring component. The analysis showed that for these conditions the tension reduced by 8-29 per cent. The results of this study highlight a general engineering problem: how can a tensioned wire be secured to a structure without an appreciable loss of tension? If the performance of the structure depends on the wire tension, this performance will change when the wire is secured.

  4. Combination of aging and dimethylhydrazine treatment causes an increase in cancer-stem cell population of rat colonic crypts.

    Science.gov (United States)

    Levi, Edi; Misra, Sandhya; Du, Jianhua; Patel, Bhaumik B; Majumdar, Adhip P N

    2009-07-31

    Aging is associated with increased incidence of colon cancers. It is also becoming evident that cancer stem cells (CSC) play a vital role in the pathogenesis and prognosis of colon cancer. Recently, we reported the presence of colon cancer stem-like cells in macroscopically normal mucosa in patients with adenomatous polyps and that they increase with aging, suggesting that aging may predispose the colon to carcinogenesis. In the current study we have examined the combined effects of aging and carcinogen exposure on the status of colon CSCs in an experimental model. We used young (4-6 months) and aged (22-24 months) rats and exposed them to the carcinogen, dimethylhydroxide (DMH). We investigated the expression of colon cancer stem cell markers, CD44, CD166, EpCam, and ALDH1 as well as EGFR expression in normal colonic crypt epithelium following carcinogen treatment. Our results demonstrate that aging per se or carcinogen treatment alone causes an increase in the number of colon cancer stems cells, as evidenced by increased immunoreactive-CSC-markers positive cells in the colonic mucosa. In aged rats, carcinogen exposure results in a more pronounced increase in colon cancer stem cells. Our study shows that in aging colon the effects of carcinogens are more pronounced, and an increase in colon CSCs is one of the earliest changes preceding tumor development. Moreover, the current investigation of the use of a panel of immunohistochemical markers of colon CSC can potentially serve as a prognostic marker during screening for colon cancer.

  5. Disability Rating, Age at Death, and Cause of Death in U.S. Veterans with Service-Connected Conditions.

    Science.gov (United States)

    Maynard, Charles; Trivedi, Ranak; Nelson, Karin; Fihn, Stephan D

    2018-03-26

    The association between disability and cause of death in Veterans with service-connected disabilities has not been studied. The objective of this study was to compare age at death, military service and disability characteristics, including disability rating, and cause of death by year of birth. We also examined cause of death for specific service-connected conditions. This study used information from the VETSNET file, which is a snapshot of selected items from the Veterans Benefits Administration corporate database. We also used the National Death Index (NDI) for Veterans which is part of the VA Suicide Data Repository. In VETSNET, there were 758,324 Veterans who had a service-connected condition and died between the years 2004 and 2014. Using the scrambled social security number to link the two files resulted in 605,493 (80%) deceased Veterans. Age at death, sex, and underlying cause of death were obtained from the NDI for Veterans and military service characteristics and types of disability were acquired from VETSNET. We constructed age categories corresponding to period of service; birth years 1938 and earlier corresponded to Korea and World War II ("oldest"), birth years 1939-1957 to the Vietnam era ("middle"), and birth years 1958 and later to post Vietnam, Gulf War, and the more recent conflicts in Iraq and Afghanistan ("youngest"). Sixty-two percent were in the oldest age category, 34% in the middle group, and 4% in the youngest one. The overall age at death was 75 ± 13 yr. Only 1.6% of decedents were women; among women 25% were in the youngest age group, while among men only 4% were in the youngest group. Most decedents were enlisted personnel, and 60% served in the U.S. Army. Nearly 61% had a disability rating of >50% and for the middle age group 54% had a disability rating of 100%. The most common service-connected conditions were tinnitus, hearing loss, and post-traumatic stress disorder (PTSD). In the oldest group, nearly half of deaths were due to

  6. Dental Arch Wire

    Science.gov (United States)

    1979-01-01

    Straightening teeth is an arduous process requiring months, often years, of applying corrective pressure by means of arch wires-better known as brace-which may have to be changed several times in the course of treatment. A new method has been developed by Dr. George Andreasen, orthodontist and dental scientist at the University of Iowa. The key is a new type of arch wire material, called Nitinol, with exceptional elasticity which helps reduce the required number of brace changes. An alloy of nickel and titanium, Nitinol was originally developed for aerospace applications by the Naval Ordnance Laboratory, now the Naval Surface Weapons Laboratory, White Oaks, Maryland. NASA subsequently conducted additional research on the properties of Nitinol and on procedures for processing the metal.

  7. Autopsy-determined causes of death following organ transplantation in 25 patients aged 20 years or younger.

    Science.gov (United States)

    Rose, Alan G

    2003-01-01

    This study aims to examine the autopsy-determined principal and proximate causes of death in 25 patients aged 20 years or younger who died during the 10-year period from 1990 to 1999 after receiving an organ transplant at the University of Minnesota/Fairview-University Medical Center. The autopsy records of this institution were examined for organ transplant recipients who were aged 20 years or younger at the time of their death. In each case, after review of the clinical and pathological data, the principle cause of death (PCOD), as well as the proximate cause of death (PXCOD) were noted. A total of 25 recipient patients were identified (five heart, five lung, five kidney and 10 liver transplants). Seven patients died 30 days or less post-operatively and 18 died thereafter. The following categories of PCOD were encountered: operative/technical complications 28%, most (6/7) being associated with liver transplantation. Infection (24%) and chronic rejection (12%) were other important PCOD. Respiratory complications accounted for 47% of the PCOD. The following categories of PXCOD were noted: technical problems 16%, pulmonary pathology 24%, miscellaneous 32%, acute rejection 4% and nil 20%. This study revealed that technical problems in liver transplants were an important PCOD; respiratory complications and chronic rejection were additional major causes of mortality in this young age group of transplant recipients. Pulmonary pathology and technical problems were the commonest specific groups contributing to the PXCOD.

  8. Usefulness of magnetic resonance imaging for diagnosing meniscal tearing. Differences in diagnostic rates according to age of patients and causes

    International Nuclear Information System (INIS)

    Iso, Yoshinori

    1996-01-01

    To clarify the differences in the diagnostic rate for meniscal tearing according to patients' ages and causes, we conducted magnetic resonance imaging (MRI) in 184 knees of 175 patients. We compared the findings of arthrography, gross examination, arthroscopy, and histopathology. Arthrography in patients with meniscal tears showed 63.0% sensitivity, 89.1% specificity, and 84.9% accuracy. MRI in the same patients disclosed 82.9% sensitivity, 86.0% specificity, and 85.5% accuracy, levels nearly similar to those of arthrography. Findings by arthrography according to patients' ages revealed no difference in each age group, whereas findings by MRI showed significant decreases of brightness in patients 40 years old or over. Diminished diagnostic rates by MRI resulted from increased changes of brightness in the menisci that had been caused by histological changes such as mucoid and hyalinization. Examination, however, of patients less than 40 years old under light microscopy revealed no menisci degeneration as a cause for the changes of MRI brightness. Based on the present situation in which lateral-site medial-meniscus diagnosis is difficult, especially in middle-aged and elderly patients, it is considered necessary to combine arthrography with MRI to obtain accurate diagnoses. (author)

  9. Vienna Wire Chamber Conference

    International Nuclear Information System (INIS)

    Anon.

    1983-01-01

    After those of 1978 and 1980, a third Wire Chamber Conference was held from 15-18 February in the Technical University of Vienna. Eight invited speakers covered the field from sophisticated applications in biology and medicine, via software, to the state of the art of gaseous detectors. In some forty other talks the speakers tackled in more detail the topics of gaseous detectors, calorimetry and associated electronics and software

  10. Prevalence and causes of reduced visual acuity among children aged three to six years in a metropolis in China.

    Science.gov (United States)

    Pan, Chen-Wei; Chen, Xuejuan; Gong, Yu; Yu, Jiajia; Ding, Hui; Bai, Jing; Chen, Ji; Zhu, Hui; Fu, Zhujun; Liu, Hu

    2016-03-01

    To determine the prevalence and possible causes for reduced visual acuity (VA) in preschool children in a metropolis in China. A school-based paediatric eye survey including 5862 preschool children aged three to 6 years was conducted from 2011 to 2012 in Yuhuatai District, Nanjing, China, using an age-stratified random sampling procedure. Clinical examinations including ocular alignment, ocular motility, visual acuity, prism cover test, cycloplegic refraction, stereopsis screening, slit lamp examination and fundus examination were performed by trained study ophthalmologists and optometrists. Reduced VA was defined as presenting VA of worse than 0.30 logMAR (Snellen 6/12 or 20/40), for both better and worse eyes. 5667 (94.8%) children with complete VA data were included in the data analyses. Among them, 208 and 93 had reduced VA in the worse and better eye, respectively. Reduced VA was detected in 3.7% (95% confidence interval [CI] 3.2%-4.2%) in the worse eye and 1.6% (95% CI 1.3%-2.0%) in the better eye. No significant age and gender differences in reduced VA were observed (p > 0.05). Refractive errors and amblyopia were the principal causes for reduced VA in the worse eye which accounted for 66.8% and 32.7% of the total cases with reduced VA, respectively. Astigmatism and hyperopia were the major types of refractive errors causing reduced VA. The burden of reduced VA in preschool children in China was similar to that of Asian children of similar ages in the United States. Uncorrected refractive error and amblyopia were the principal causes for reduced VA among preschoolers (aged three to 6 years) in China. © 2015 The Authors Ophthalmic & Physiological Optics © 2015 The College of Optometrists.

  11. Arthrodesis of distal interphalangeal joints in the hand with interosseous wiring and intramedullary K-wire fixation.

    Science.gov (United States)

    Han, Soo Hong; Cha, Yoon Sik; Song, Won Tae

    2014-12-01

    To evaluate the efficacy of intramedullary K-wire fixation and interosseous wiring in the arthrodesis of the distal interphalangeal (DIP) joint with description of surgical procedure. We retrospectively analyzed 9 cases (7 women and 2 men) of DIP joint arthrodesis. The average age of patients was 44.2 years (range, 21 to 71 years) and the mean follow-up period was 19.6 months. Joint union was evaluated on the follow-up radiographs together with postoperative complications. All cases achieved radiologic union of the arthrodesis site. There was no surgical complication except for one case of skin irritation by the interosseous wire knot which was removed during the follow-up period. Intramedullary K-wire fixation and interosseous wiring could be an alternative procedure of arthrodesis in the DIP joint.

  12. Age and Diet Affect Genetically Separable Secondary Injuries that Cause Acute Mortality Following Traumatic Brain Injury in Drosophila

    Directory of Open Access Journals (Sweden)

    Rebeccah J. Katzenberger

    2016-12-01

    Full Text Available Outcomes of traumatic brain injury (TBI vary because of differences in primary and secondary injuries. Primary injuries occur at the time of a traumatic event, whereas secondary injuries occur later as a result of cellular and molecular events activated in the brain and other tissues by primary injuries. We used a Drosophila melanogaster TBI model to investigate secondary injuries that cause acute mortality. By analyzing mortality percentage within 24 hr of primary injuries, we previously found that age at the time of primary injuries and diet afterward affect the severity of secondary injuries. Here, we show that secondary injuries peaked in activity 1–8 hr after primary injuries. Additionally, we demonstrate that age and diet activated distinct secondary injuries in a genotype-specific manner, and that concurrent activation of age- and diet-regulated secondary injuries synergistically increased mortality. To identify genes involved in secondary injuries that cause mortality, we compared genome-wide mRNA expression profiles of uninjured and injured flies under age and diet conditions that had different mortalities. During the peak period of secondary injuries, innate immune response genes were the predominant class of genes that changed expression. Furthermore, age and diet affected the magnitude of the change in expression of some innate immune response genes, suggesting roles for these genes in inhibiting secondary injuries that cause mortality. Our results indicate that the complexity of TBI outcomes is due in part to distinct, genetically controlled, age- and diet-regulated mechanisms that promote secondary injuries and that involve a subset of innate immune response genes.

  13. Age and Diet Affect Genetically Separable Secondary Injuries that Cause Acute Mortality Following Traumatic Brain Injury in Drosophila.

    Science.gov (United States)

    Katzenberger, Rebeccah J; Ganetzky, Barry; Wassarman, David A

    2016-12-07

    Outcomes of traumatic brain injury (TBI) vary because of differences in primary and secondary injuries. Primary injuries occur at the time of a traumatic event, whereas secondary injuries occur later as a result of cellular and molecular events activated in the brain and other tissues by primary injuries. We used a Drosophila melanogaster TBI model to investigate secondary injuries that cause acute mortality. By analyzing mortality percentage within 24 hr of primary injuries, we previously found that age at the time of primary injuries and diet afterward affect the severity of secondary injuries. Here, we show that secondary injuries peaked in activity 1-8 hr after primary injuries. Additionally, we demonstrate that age and diet activated distinct secondary injuries in a genotype-specific manner, and that concurrent activation of age- and diet-regulated secondary injuries synergistically increased mortality. To identify genes involved in secondary injuries that cause mortality, we compared genome-wide mRNA expression profiles of uninjured and injured flies under age and diet conditions that had different mortalities. During the peak period of secondary injuries, innate immune response genes were the predominant class of genes that changed expression. Furthermore, age and diet affected the magnitude of the change in expression of some innate immune response genes, suggesting roles for these genes in inhibiting secondary injuries that cause mortality. Our results indicate that the complexity of TBI outcomes is due in part to distinct, genetically controlled, age- and diet-regulated mechanisms that promote secondary injuries and that involve a subset of innate immune response genes. Copyright © 2016 Katzenberger et al.

  14. Magnetic domain propagation in Pt/Co/Pt micro wires with engineered coercivity gradients along and across the wire

    Energy Technology Data Exchange (ETDEWEB)

    Jarosz, A., E-mail: arctgh@ifmpan.poznan.pl [Institute of Molecular Physics, Polish Academy of Sciences, ul. M. Smoluchowskiego 17, 60-179 Poznań (Poland); Gaul, A. [Department of Physics and Center for Interdisciplinary Nanostructure Science and Technology (CINSaT), University of Kassel, Heinrich-Plett-Str. 40, D-34132 Kassel (Germany); Urbaniak, M. [Institute of Molecular Physics, Polish Academy of Sciences, ul. M. Smoluchowskiego 17, 60-179 Poznań (Poland); Ehresmann, A. [Department of Physics and Center for Interdisciplinary Nanostructure Science and Technology (CINSaT), University of Kassel, Heinrich-Plett-Str. 40, D-34132 Kassel (Germany); Stobiecki, F. [Institute of Molecular Physics, Polish Academy of Sciences, ul. M. Smoluchowskiego 17, 60-179 Poznań (Poland)

    2017-08-01

    Highlights: • Electron lithography and ion bombardment were used to modify the Co/Pt micro-wires. • Two-dimensional perpendicular magnetic anisotropy gradient was engineered. • Engineered anisotropy gradient allowed to control domain wall positions in the wires. • Simulations confirm the influence of defects on a remanent state of the wires. - Abstract: Pt(15 nm)/[Co(0.6 nm)/Pt(1.5 nm)]{sub 4} multilayers with perpendicular magnetic anisotropy were patterned into several-micrometer wide wires by electron-beam lithography. Bombarding the wires with He{sup +} ions with a fluence gradient along the wire results in a spatial gradient of switching fields that allows a controllable positioning of domain walls. The influence of the reduced anisotropy near the wire edges causes a remanent state in which the reversal close to the long edges precedes that in the middle of the wires. Experiments using Kerr microscopy prove this effect and micromagnetic simulations corroborate that a decrease of the anisotropy at the edges is responsible for the effect.

  15. Dual wire welding torch and method

    Science.gov (United States)

    Diez, Fernando Martinez; Stump, Kevin S.; Ludewig, Howard W.; Kilty, Alan L.; Robinson, Matthew M.; Egland, Keith M.

    2009-04-28

    A welding torch includes a nozzle with a first welding wire guide configured to orient a first welding wire in a first welding wire orientation, and a second welding wire guide configured to orient a second welding wire in a second welding wire orientation that is non-coplanar and divergent with respect to the first welding wire orientation. A method of welding includes moving a welding torch with respect to a workpiece joint to be welded. During moving the welding torch, a first welding wire is fed through a first welding wire guide defining a first welding wire orientation and a second welding wire is fed through a second welding wire guide defining a second welding wire orientation that is divergent and non-coplanar with respect to the first welding wire orientation.

  16. Age-related formaldehyde interferes with DNA methyltransferase function, causing memory loss in Alzheimer's disease.

    Science.gov (United States)

    Tong, Zhiqian; Han, Chanshuai; Qiang, Min; Wang, Weishan; Lv, Jihui; Zhang, Shouzi; Luo, Wenhong; Li, Hui; Luo, Hongjun; Zhou, Jiangning; Wu, Beibei; Su, Tao; Yang, Xu; Wang, Xiaomin; Liu, Ying; He, Rongqiao

    2015-01-01

    Hippocampus-related topographic amnesia is the most common symptom of memory disorders in Alzheimer's disease (AD) patients. Recent studies have revealed that experience-mediated DNA methylation, which is regulated by enzymes with DNA methyltransferase (DNMT) activity, is required for the formation of recent memory as well as the maintenance of remote memory. Notably, overexpression of DNMT3a in the hippocampus can reverse spatial memory deficits in aged mice. However, a decline in global DNA methylation was found in the autopsied hippocampi of patients with AD. Exactly, what endogenous factors that affect DNA methylation still remain to be elucidated. Here, we report a marked increase in endogenous formaldehyde levels is associated with a decline in global DNA methylation in the autopsied hippocampus from AD patients. In vitro and in vivo results show that formaldehyde in excess of normal physiological levels reduced global DNA methylation by interfering DNMTs. Interestingly, intrahippocampal injection of excess formaldehyde before spatial learning in healthy adult rats can mimic the learning difficulty of early stage of AD. Moreover, injection of excess formaldehyde after spatial learning can mimic the loss of remote spatial memory observed in late stage of AD. These findings suggest that aging-associated formaldehyde contributes to topographic amnesia in AD patients. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Causes of ice age intensification across the Mid-Pleistocene Transition

    Science.gov (United States)

    Chalk, Thomas B.; Hain, Mathis P.; Foster, Gavin L.; Rohling, Eelco J.; Sexton, Philip F.; Badger, Marcus P. S.; Cherry, Soraya G.; Hasenfratz, Adam P.; Haug, Gerald H.; Jaccard, Samuel L.; Martínez-García, Alfredo; Pälike, Heiko; Pancost, Richard D.; Wilson, Paul A.

    2017-12-01

    During the Mid-Pleistocene Transition (MPT; 1,200–800 kya), Earth's orbitally paced ice age cycles intensified, lengthened from ˜40,000 (˜40 ky) to ˜100 ky, and became distinctly asymmetrical. Testing hypotheses that implicate changing atmospheric CO2 levels as a driver of the MPT has proven difficult with available observations. Here, we use orbitally resolved, boron isotope CO2 data to show that the glacial to interglacial CO2 difference increased from ˜43 to ˜75 μatm across the MPT, mainly because of lower glacial CO2 levels. Through carbon cycle modeling, we attribute this decline primarily to the initiation of substantive dust-borne iron fertilization of the Southern Ocean during peak glacial stages. We also observe a twofold steepening of the relationship between sea level and CO2-related climate forcing that is suggestive of a change in the dynamics that govern ice sheet stability, such as that expected from the removal of subglacial regolith or interhemispheric ice sheet phase-locking. We argue that neither ice sheet dynamics nor CO2 change in isolation can explain the MPT. Instead, we infer that the MPT was initiated by a change in ice sheet dynamics and that longer and deeper post-MPT ice ages were sustained by carbon cycle feedbacks related to dust fertilization of the Southern Ocean as a consequence of larger ice sheets.

  18. Flexural magneto-elastic vibrations of thin metal wires

    International Nuclear Information System (INIS)

    Lukyanov, A; Molokov, S

    2004-01-01

    Flexural vibrations of thin metal wires owing to a high, pulsed electric current have been investigated. The current is sufficiently low to inhibit melting but sufficiently high to induce stresses, leading to the wire fragmentation. The problem is treated numerically on the basis of the theory of three-dimensional linear elasticity. The model has been verified on the well-known exact, eigenmode solution for the flexural vibrations of an infinite wire. The agreement is excellent. Further, the model has been used to study vibrations owing to two sources. The first one is perturbations of wires owing to the Lorentz force leading to a kink-type instability similar to that in plasmas. As the main cause of the wire fragmentation has been previously found to be the thermal expansion of material owing to Joule heating, this problem mainly serves to compare results between the three-dimensional and the one-dimensional, thin-rod models. Comparison of the growth rate of the instability obtained by the two models has shown an excellent agreement. The second source of vibrations is the magnetic fields induced in the external electric circuit. The results show that depending on the shape of the circuit, the induced stresses may exceed 20 MPa for the aluminium wires used in the low-current experiments. Although the external fields are not the main source of the wire fragmentation, these values alone may cause the fracture process at elevated temperatures

  19. Experience of precision measuring distances by invar wires at accelerators

    International Nuclear Information System (INIS)

    Porubaj, N.I.

    1977-01-01

    With a view to determining the deformations and displacements of the ring foundation of the ITEP accelerator, the method of very accurate distance measurements by means of invar wires and strips is described. Measurement errors are analyzed. This method has allowed to measure distances up to 40 m with a mean-square error of less than 40 μm. The calibration accuracy of 3 and 25-m measuring wires has been determined to be +- 27 μm. Time instability of the wires is +- 16 μm. It is shown that strips are more stable in time than wires. Elongation of 6, 19, 25 and 38 m invar wires has been measured as function of the tension time. The error due to tension of a 38-m wire may be tangible. Data on thermal coefficient variation in time has been obtained for invar wires and strips. The multiannual measurements of the ring foundation deformations show that variations of the mean radius are caused by increases of concrete temperature. Temperature increase by only 1 deg caused mean radius increase of 0.3 mm

  20. Seasonal variations of all-cause and cause-specific mortality by age, gender, and socioeconomic condition in urban and rural areas of Bangladesh

    Directory of Open Access Journals (Sweden)

    Burkart Katrin

    2011-08-01

    Full Text Available Abstract Background Mortality exhibits seasonal variations, which to a certain extent can be considered as mid-to long-term influences of meteorological conditions. In addition to atmospheric effects, the seasonal pattern of mortality is shaped by non-atmospheric determinants such as environmental conditions or socioeconomic status. Understanding the influence of season and other factors is essential when seeking to implement effective public health measures. The pressures of climate change make an understanding of the interdependencies between season, climate and health especially important. Methods This study investigated daily death counts collected within the Sample Vital Registration System (VSRS established by the Bangladesh Bureau of Statistics (BBS. The sample was stratified by location (urban vs. rural, gender and socioeconomic status. Furthermore, seasonality was analyzed for all-cause mortality, and several cause-specific mortalities. Daily deviation from average mortality was calculated and seasonal fluctuations were elaborated using non parametric spline smoothing. A seasonality index for each year of life was calculated in order to assess the age-dependency of seasonal effects. Results We found distinctive seasonal variations of mortality with generally higher levels during the cold season. To some extent, a rudimentary secondary summer maximum could be observed. The degree and shape of seasonality changed with the cause of death as well as with location, gender, and SES and was strongly age-dependent. Urban areas were seen to be facing an increased summer mortality peak, particularly in terms of cardiovascular mortality. Generally, children and the elderly faced stronger seasonal effects than youths and young adults. Conclusion This study clearly demonstrated the complex and dynamic nature of seasonal impacts on mortality. The modifying effect of spatial and population characteristics were highlighted. While tropical regions have

  1. Rapid climate change did not cause population collapse at the end of the European Bronze Age.

    Science.gov (United States)

    Armit, Ian; Swindles, Graeme T; Becker, Katharina; Plunkett, Gill; Blaauw, Maarten

    2014-12-02

    The impact of rapid climate change on contemporary human populations is of global concern. To contextualize our understanding of human responses to rapid climate change it is necessary to examine the archeological record during past climate transitions. One episode of abrupt climate change has been correlated with societal collapse at the end of the northwestern European Bronze Age. We apply new methods to interrogate archeological and paleoclimate data for this transition in Ireland at a higher level of precision than has previously been possible. We analyze archeological (14)C dates to demonstrate dramatic population collapse and present high-precision proxy climate data, analyzed through Bayesian methods, to provide evidence for a rapid climatic transition at ca. 750 calibrated years B.C. Our results demonstrate that this climatic downturn did not initiate population collapse and highlight the nondeterministic nature of human responses to past climate change.

  2. Signs vs. Causes? An Epistemological Approach to Prognosis in the Latin Middle Ages

    Directory of Open Access Journals (Sweden)

    Alexander Fidora

    2014-12-01

    Full Text Available From the 12th century onwards, prognostic disciplines were part and parcel of the Latin ordo scientiarum. This is true for astrology and divination as well as for medicine and weather forecasting. While scholarly research has focused very much on the moral discussions of knowledge of the future in the Middle Ages, the epistemological challenge of integrating this form of knowledge into a coherent theoretical framework has been neglected so far. This article shows how the traditional account of prognostic disciplines as sign-based forms of knowledge was revised and refined during the 13 th century in the light of new philosophical (Aristotelian and also theological paradigms. As a result of this, Latin philosophers and theologians established important criteria which allowed for a clear-cut epistemological distinction between different forms of prognostic signs and thus radicalized the discussion about the legitimacy of some prognostic disciplines.

  3. Metering Wheel-Wire Track Wire Boom Deployment Mechanism

    Science.gov (United States)

    Granoff, Mark S.

    2014-01-01

    The NASA MMS Spin Plane Double Probe (SDP) Deployer utilizes a helical path, rotating Metering Wheel and a spring loaded Wire "Holding" Track to pay out a "fixed end" 57 meter x 1.5 mm diameter Wire Boom stored between concentric storage cylinders. Unlike rotating spool type storage devices, the storage cylinders remain stationary, and the boom wire is uncoiled along the length of the cylinder via the rotation of the Metering Wheel. This uncoiling action avoids the need for slip-ring contacts since the ends of the wire can remain stationary. Conventional fixed electrical connectors (Micro-D type) are used to terminate to operational electronics.

  4. Causes of chronic non-infectious diarrhoea in infants less than 6 months of age: rarely recognized entities

    International Nuclear Information System (INIS)

    Mushtaq, I.; Cheema, H.A.; Malik, H.S.; Waheed, N.; Hashmi, M.A.

    2017-01-01

    Non-infectious causes of chronic diarrhoea are important and easily missed. The study was done with the objectives to identify different causes of chronic non-infectious diarrhoea in infants less than 6 months of age. Methods: All patients less than 6 months of age presenting for the first time to a Paediatric Gastroenterology tertiary care centre with a history of chronic diarrhoea and negative stool cultures, were enrolled over a period of 8 months. Demographical profile and various factors under observation were recorded in this observational study. Collected data was analysed using SPSS version 20. Chi square test was applied as a test of significance for any qualitative variable, p value (p<0.05) was taken as significant. Results: Among 72 enrolled patients, female to male ratio was 1.05:1. Age at onset of symptoms was between 15 days to 06 months. Aetiology found was Cow's milk protein allergy (CMPA) in 58 (80.6%), Primary intestinal lymphangiectasia (PIL) 6 (8.3%), Cystic fibrosis (CF) 3 (4.2%), Immunodeficiency (SCID) 2 (2.8%), 1 (1.4%) for each Abetalipoproteinemia (ABL), Glucose galactose malabsorption (GGM) and Congenital chloride diarrhoea (CCD). Conclusions: Among non-infectious causes of chronic diarrhoea in early infancy, cow's milk protein allergy is most common followed by Primary intestinal lymphangiectasia and Cystic fibrosis. (author)

  5. Analysis of tetragonal to monoclinic phase transformation caused by accelerated artificial aging and the effects of microstructure in stabilized zirconia

    Science.gov (United States)

    Lucas, Thomas J.

    This investigation addresses the issue that yttria stabilized zirconia is being used as a dental biomaterial without substantial evidence of its long-term viability. Furthermore, stabilized zirconia (SZ) undergoes low temperature degradation (LTD), which can lead to roughening of the surface. A rougher exterior can lead to increased wear of the antagonist in the oral environment. Despite the LTD concerns, SZ is now widely used in restorative dentistry, including full contour crowns. A comparison of aging methods to determine the role of artificial aging on inducing the transformation has not been extensively studied. Therefore, simulations of the transformation process were investigated by comparing different methods of accelerated aging. The rejected null hypothesis is that the temperature of aging treatment will not affect the time required to cause measurable monoclinic transformation of yttria stabilized zirconia. The transformation of SZ starts at the surface and progresses inward; however, it is unclear whether the progression is constant for different aging conditions. This investigation analyzed the depth of transformation as a function of aging conditions for stabilized zirconia in the top 5-6 mum from the surface. The rejected null hypothesis is that the transformation amount is constant throughout the first six micrometers from the surface. The effects of grain size on the amount of monoclinic transformation were also investigated. This study aimed to determine if the grain size of partially stabilized zirconia affects the amount of monoclinic transformation, surface roughness, and property degradation due to aging. The rejected null hypothesis is that the grain size will not affect the amount of monoclinic transformation, thus have no effect on surface roughening or property degradation. The final part of this study addresses the wear of enamel when opposing zirconia by observing how grain size and aging affected the wear rate of an enamel antagonist

  6. Aging

    International Nuclear Information System (INIS)

    Sasaki, Hideo; Kodama, Kazunori; Yamada, Michiko

    1991-01-01

    The hypothesis that exposure to ionizing radiation accelerates the aging process has been actively investigated at ABCC-RERF since 1958, when longitudinal cohort studies of the Adult Health Study (AHS) and the Life Span Study (LSS) were initiated. In their 1975 overall review of aging studies related to the atomic bomb (A-bomb) survivors, Finch and Beebe concluded that while most studies had shown no correlation between aging and radiation exposure, they had not involved the large numbers of subjects required to provide strong evidence for or against the hypothesis. Extending LSS mortality data up to 1978 did not alter the earlier conclusion that any observed life-shortening was associated primarily with cancer induction rather than with any nonspecific cause. The results of aging studies conducted during the intervening 15 years using data from the same populations are reviewed in the present paper. Using clinical, epidemiological, and laboratory techniques, a broad spectrum of aging parameters have been studied, such as postmortem morphological changes, tests of functional capacity, physical tests and measurements, laboratory tests, tissue changes, and morbidity. With respect to the aging process, the overall results have not been consistent and are generally thought to show no relation to radiation exposure. Although some preliminary results suggest a possible radiation-induced increase in atherosclerotic diseases and acceleration of aging in the T-cell-related immune system, further study is necessary to confirm these findings. In the future, applying the latest gerontological study techniques to data collected from subjects exposed 45 years ago to A-bomb radiation at relatively young ages will present a new body of data relevant to the study of late radiation effects. (author) 103 refs

  7. Endogenous reactive oxygen species cause astrocyte defects and neuronal dysfunctions in the hippocampus: a new model for aging brain.

    Science.gov (United States)

    Ishii, Takamasa; Takanashi, Yumi; Sugita, Koichi; Miyazawa, Masaki; Yanagihara, Rintaro; Yasuda, Kayo; Onouchi, Hiromi; Kawabe, Noboru; Nakata, Munehiro; Yamamoto, Yorihiro; Hartman, Phil S; Ishii, Naoaki

    2017-02-01

    The etiology of astrocyte dysfunction is not well understood even though neuronal defects have been extensively studied in a variety of neuronal degenerative diseases. Astrocyte defects could be triggered by the oxidative stress that occurs during physiological aging. Here, we provide evidence that intracellular or mitochondrial reactive oxygen species (ROS) at physiological levels can cause hippocampal (neuronal) dysfunctions. Specifically, we demonstrate that astrocyte defects occur in the hippocampal area of middle-aged Tet-mev-1 mice with the SDHC V69E mutation. These mice are characterized by chronic oxidative stress. Even though both young adult and middle-aged Tet-mev-1 mice overproduced MitoSOX Red-detectable mitochondrial ROS compared to age-matched wild-type C57BL/6J mice, only young adult Tet-mev-1 mice upregulated manganese and copper/zinc superoxide dismutase (Mn- and Cu/Zn-SODs) activities to eliminate the MitoSOX Red-detectable mitochondrial ROS. In contrast, middle-aged Tet-mev-1 mice accumulated both MitoSOX Red-detectable mitochondrial ROS and CM-H 2 DCFDA-detectable intracellular ROS. These ROS levels appeared to be in the physiological range as shown by normal thiol and glutathione disulfide/glutathione concentrations in both young adult and middle-aged Tet-mev-1 mice relative to age-matched wild-type C57BL/6J mice. Furthermore, only middle-aged Tet-mev-1 mice showed JNK/SAPK activation and Ca 2+ overload, particularly in astrocytes. This led to decreasing levels of glial fibrillary acidic protein and S100β in the hippocampal area. Significantly, there were no pathological features such as apoptosis, amyloidosis, and lactic acidosis in neurons and astrocytes. Our findings suggest that the age-dependent physiologically relevant chronic oxidative stress caused astrocyte defects in mice with impaired mitochondrial electron transport chain functionality. © 2016 The Authors. Aging Cell published by the Anatomical Society and John Wiley & Sons Ltd.

  8. Uninephrectomy in young age or chronic salt loading causes salt-sensitive hypertension in adult rats

    DEFF Research Database (Denmark)

    Carlström, Mattias; Sällström, Johan; Skøtt, Ole

    2007-01-01

    animals raised with normal-salt diet (UNX) or high-salt diet (UNX+HS). In the adult animals, renal and cardiovascular functions were evaluated and blood pressure recorded telemetrically under different sodium conditions (normal, high, and low). Hypertension was present in UNX+HS (122+/-9 mm Hg), UNX (101......+/-3 mm Hg), and HS (96+/-1 mm Hg) groups on normal-salt diets compared with the controls (84+/-2 mm Hg), and the blood pressure was salt sensitive (high- versus normal-salt diet; 23+/-3, 9+/-2, 7+/-2, and 1+/-1 mm Hg, respectively). The hypertensive groups (UNX+HS, UNX, and HS) had increased diuresis......The importance of nephron endowment and salt intake for the development of hypertension is under debate. The present study was designed to investigate whether reduced nephron number, after completion of nephrogenesis, or chronic salt loading causes renal injury and salt-sensitive hypertension...

  9. The Protective Effect of Lipoic Acid on Selected Cardiovascular Diseases Caused by Age-Related Oxidative Stress

    Directory of Open Access Journals (Sweden)

    Beata Skibska

    2015-01-01

    Full Text Available Oxidative stress is considered to be the primary cause of many cardiovascular diseases, including endothelial dysfunction in atherosclerosis and ischemic heart disease, hypertension, and heart failure. Oxidative stress increases during the aging process, resulting in either increased reactive oxygen species (ROS production or decreased antioxidant defense. The increase in the incidence of cardiovascular disease is directly related to age. Aging is also associated with oxidative stress, which in turn leads to accelerated cellular senescence and organ dysfunction. Antioxidants may help lower the incidence of some pathologies of cardiovascular diseases and have antiaging properties. Lipoic acid (LA is a natural antioxidant which is believed to have a beneficial effect on oxidative stress parameters in relation to diseases of the cardiovascular system.

  10. The Protective Effect of Lipoic Acid on Selected Cardiovascular Diseases Caused by Age-Related Oxidative Stress

    Science.gov (United States)

    Goraca, Anna

    2015-01-01

    Oxidative stress is considered to be the primary cause of many cardiovascular diseases, including endothelial dysfunction in atherosclerosis and ischemic heart disease, hypertension, and heart failure. Oxidative stress increases during the aging process, resulting in either increased reactive oxygen species (ROS) production or decreased antioxidant defense. The increase in the incidence of cardiovascular disease is directly related to age. Aging is also associated with oxidative stress, which in turn leads to accelerated cellular senescence and organ dysfunction. Antioxidants may help lower the incidence of some pathologies of cardiovascular diseases and have antiaging properties. Lipoic acid (LA) is a natural antioxidant which is believed to have a beneficial effect on oxidative stress parameters in relation to diseases of the cardiovascular system. PMID:25949771

  11. Mutant TDP-43 and FUS Cause Age-Dependent Paralysis and Neurodegeneration in C. elegans

    Science.gov (United States)

    Vaccaro, Alexandra; Tauffenberger, Arnaud; Aggad, Dina; Rouleau, Guy; Drapeau, Pierre; Parker, J. Alex

    2012-01-01

    Mutations in the DNA/RNA binding proteins TDP-43 and FUS are associated with Amyotrophic Lateral Sclerosis and Frontotemporal Lobar Degeneration. Intracellular accumulations of wild type TDP-43 and FUS are observed in a growing number of late-onset diseases suggesting that TDP-43 and FUS proteinopathies may contribute to multiple neurodegenerative diseases. To better understand the mechanisms of TDP-43 and FUS toxicity we have created transgenic Caenorhabditis elegans strains that express full-length, untagged human TDP-43 and FUS in the worm's GABAergic motor neurons. Transgenic worms expressing mutant TDP-43 and FUS display adult-onset, age-dependent loss of motility, progressive paralysis and neuronal degeneration that is distinct from wild type alleles. Additionally, mutant TDP-43 and FUS proteins are highly insoluble while wild type proteins remain soluble suggesting that protein misfolding may contribute to toxicity. Populations of mutant TDP-43 and FUS transgenics grown on solid media become paralyzed over 7 to 12 days. We have developed a liquid culture assay where the paralysis phenotype evolves over several hours. We introduce C. elegans transgenics for mutant TDP-43 and FUS motor neuron toxicity that may be used for rapid genetic and pharmacological suppressor screening. PMID:22363618

  12. Coffee Silverskin Extract Protects against Accelerated Aging Caused by Oxidative Agents

    Directory of Open Access Journals (Sweden)

    Amaia Iriondo-DeHond

    2016-06-01

    Full Text Available Nowadays, coffee beans are almost exclusively used for the preparation of the beverage. The sustainability of coffee production can be achieved introducing new applications for the valorization of coffee by-products. Coffee silverskin is the by-product generated during roasting, and because of its powerful antioxidant capacity, coffee silverskin aqueous extract (CSE may be used for other applications, such as antiaging cosmetics and dermaceutics. This study aims to contribute to the coffee sector’s sustainability through the application of CSE to preserve skin health. Preclinical data regarding the antiaging properties of CSE employing human keratinocytes and Caenorhabditis elegans are collected during the present study. Accelerated aging was induced by tert-butyl hydroperoxide (t-BOOH in HaCaT cells and by ultraviolet radiation C (UVC in C. elegans. Results suggest that the tested concentrations of coffee extracts were not cytotoxic, and CSE 1 mg/mL gave resistance to skin cells when oxidative damage was induced by t-BOOH. On the other hand, nematodes treated with CSE (1 mg/mL showed a significant increased longevity compared to those cultured on a standard diet. In conclusion, our results support the antiaging properties of the CSE and its great potential for improving skin health due to its antioxidant character associated with phenols among other bioactive compounds present in the botanical material.

  13. Age of oil palm plantations causes a strong change in surface biophysical variables

    Science.gov (United States)

    Sabajo, Clifton; le Maire, Guerric; Knohl, Alexander

    2016-04-01

    Over the last decades, Indonesia has experienced dramatic land transformations with an expansion of oil palm plantations at the expense of tropical forests. As vegetation is a modifier of the climate near the ground these large-scale land transformations are expected to have major impacts on the surface biophysical variables i.e. surface temperature, albedo, and vegetation indices, e.g. the NDVI. Remote sensing data are needed to assess such changes at regional scale. We used 2 Landsat images from Jambi Province in Sumatra/Indonesia covering a chronosequence of oil palm plantations to study the 20 - 25 years life cycle of oil palm plantations and its relation with biophysical variables. Our results show large differences between the surface temperature of young oil palm plantations and forest (up to 9.5 ± 1.5 °C) indicating that the surface temperature is raised substantially after the establishment of oil palm plantations following the removal of forests. During the oil palm plantation lifecycle the surface temperature differences gradually decreases and approaches zero around an oil palm plantation age of 10 years. Similarly, NDVI increases and the albedo decreases approaching typical values of forests. Our results show that in order to assess the full climate effects of oil palm expansion biophysical processes play an important role and the full life cycle of oil palm plantations need to be considered.

  14. Isolated systolic hypertension in Dutch middle aged and all-cause mortality: a 25-year prospective study.

    Science.gov (United States)

    van den Ban, G C; Kampman, E; Schouten, E G; Kok, F J; van der Heide, R M; van der Heide-Wessel, C

    1989-03-01

    In the early 1950s, the blood pressure of 3901 Dutch civil servants and their spouses aged 40-65 years was measured in a general health survey. Isolated systolic hypertension (systolic pressure greater than 160 mmHg, diastolic pressure less than 90 mmHg) was observed in 6.3% of the women and 3.0% of the men. The prevalence increased with age and it was more common in women in all age groups. Using logistic regression, with adjustment for potential confounders (age, smoking, serum cholesterol, Quetelet index, alcohol consumption, haemoglobin level, pulse rate and diastolic blood pressure) the association of 15- and 25-year total mortality with isolated systolic hypertension was determined. Compared to normotensive people (systolic pressure less than or equal to 135 mmHg, diastolic pressure less than 90 mmHg), the risk of death from all causes was significantly higher for men with isolated systolic hypertension after 15 and 25 years of follow-up (odds ratio OR = 2.4, 95% confidence interval (CI) 1.2-4.8 and OR = 3.2, 95% CI 1.3-8.0). For women 15-years mortality risk was strongly associated with isolated systolic hypertension (OR = 3.7, 95% CI 1.4-9.7). The increased risk was less pronounced after 25 years of follow-up (OR = 1.7, 95% CI 0.96-3.0). Our results support those of other studies and indicate that isolated systolic hypertension is an important independent risk factor for all-cause mortality. Since isolated systolic hypertension may be an indicator for the early onset of ageing, it is important to study its determinants and to pay more attention to its diagnosis and treatment in middle-aged populations.

  15. Wire communication engineering

    International Nuclear Information System (INIS)

    Son, Byeong Tae

    1997-02-01

    This book describes wire telecommunication engineering/ It is divided into eleven chapter, which deal with Introduction with development of telecommunication, voice and sound wave and communication network, Telegraphy with summary of telegraphy, code of telegraphy, communication speed, morse and telex, Telephone on structure, circuit and image telephone, Traffic on telecommunication traffic, transmission of line about theory, cable line and loaded cable, carrier communication with carrier telegraphy and carrier telephone, optical communication with types, structure, specialty, laser and equipment, DATA, Mobile telecommunication on summary, mobile telephone, radio paging and digital mobile telecommunication, ISDN with channel of ISDN, and service of ISDN, and design of telecommunication.

  16. Wiring regulations in brief

    CERN Document Server

    Tricker, Ray

    2012-01-01

    Tired of trawling through the Wiring Regs?Perplexed by Part P?Confused by cables, conductors and circuits?Then look no further! This handy guide provides an on-the-job reference source for Electricians, Designers, Service Engineers, Inspectors, Builders, Students, DIY enthusiastsTopic-based chapters link areas of working practice - such as cables, installations, testing and inspection, special locations - with the specifics of the Regulations themselves. This allows quick and easy identification of the official requirements relating to the situati

  17. The Micro Wire Detector

    Energy Technology Data Exchange (ETDEWEB)

    Adeva, B.; Gomez, F.; Pazos, A.; Pfau, R.; Plo, M. E-mail: maximo.plo@cern.ch; Rodriguez, J.M.; Vazquez, P.; Labbe, J.C

    1999-10-11

    We present the performance of a new proportional gas detector. Its geometry consists of a cathode plane with 70x70 {mu}m{sup 2} apertures, crossed by 25 {mu}m anode strips to which it is attached by 50 {mu}m kapton spacers. In the region where the avalanche takes place, the anode strips are suspended in the gas mixture as in a standard wire chamber. This detector exhibits high rate capability and large gains, introducing very little material. (author)

  18. Epitaxial semiconductor quantum wires.

    Science.gov (United States)

    Wu, J; Chen, Y H; Wang, Z G

    2008-07-01

    The investigation on the direct epitaxial quantum wires (QWR) using MBE or MOCVD has been persuited for more than two decades, more lengthy in history as compared with its quantum dot counterpart. Up to now, QWRs with various structural configurations have been produced with different growth methods. This is a reviewing article consisting mainly of two parts. The first part discusses QWRs of various configurations, together with laser devices based on them, in terms of the two growth mechanisms, self-ordering and self-assembling. The second part gives a brief review of the electrical and optical properties of QWRs.

  19. 46 CFR 111.60-11 - Wire.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Wire. 111.60-11 Section 111.60-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Wiring Materials and Methods § 111.60-11 Wire. (a) Wire must be in an enclosure. (b) Wire must be...

  20. Corrosion of Wires on Wooden Wire-Bound Packaging Crates

    Science.gov (United States)

    Samuel L. Zelinka; Stan Lebow

    2015-01-01

    Wire-bound packaging crates are used by the US Army to transport materials. Because these crates may be exposed to harsh environments, they are dip-treated with a wood preservative (biocide treatment). For many years, zinc-naphthenate was the most commonly used preservative for these packaging crates and few corrosion problems with the wires were observed. Recently,...

  1. [Separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella].

    Science.gov (United States)

    Zhang, J; Jiang, X Y; Huang, X W

    2016-06-18

    To investigate the clinical efficacy and outcomes of two separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire in the treatment of displaced inferior pole fractures of the patella. From January 2013 to January 2015, 15 consecutive patients (mean age 54.5 years) with inferior pole fractures of the patella were retrospectively included in this study. All the patients underwent open reduction and internal fixation by separate vertical wiring combined with tension band and Kirschner-wire plus cerclage wire through longitudinal incision, 4.5 d (range: 3.1-5.9 d) after initial injury. A safety check for early knee range of motion was performed before wound closure. The complications including infection, nonunion, loss of fixation and any wire breakage or irritation from implant were recorded. Anteroposterior and lateral views of the knee joint obtained during the follow-up were used to assess bony union based on the time when the fracture line disappeared. At the time of the final outpatient follow up, functional evaluation of the knee joint was conducted by Bostman system. The follow-up time was 13.1 months (range: 12-19 months) after surgery on average, immediate motion without immobilization in all the cases was allowed and there was no case of reduction loss of the fracture and wire breakage. There was no case of irritation from the implant. At the final follow-up, the average range of motion (ROM) arc was 126.7° (range: 115°-140°), the average ROM lag versus contralateral healthy leg was 10.3° (range: 0°-35°). The mean Bostman score at the last follow-up was 28.9 (range: 27-30), and graded excellent in most cases. Two separate vertical wiring is an easy and effective method to reduce the displaced inferior pole fracture of patella. Augmentation of separate vertical wiring with tension band and Kirschner-wire plus cerclage wire in these patients provides enough strength to protected the early exercise of the knee joint and

  2. Improved superconducting magnet wire

    Science.gov (United States)

    Schuller, I.K.; Ketterson, J.B.

    1983-08-16

    This invention is directed to a superconducting tape or wire composed of alternating layers of copper and a niobium-containing superconductor such as niobium of NbTi, Nb/sub 3/Sn or Nb/sub 3/Ge. In general, each layer of the niobium-containing superconductor has a thickness in the range of about 0.05 to 1.5 times its coherence length (which for Nb/sub 3/Si is 41 A) with each copper layer having a thickness in the range of about 170 to 600 A. With the use of very thin layers of the niobium composition having a thickness within the desired range, the critical field (H/sub c/) may be increased by factors of 2 to 4. Also, the thin layers of the superconductor permit the resulting tape or wire to exhibit suitable ductility for winding on a magnet core. These compositions are also characterized by relatively high values of critical temperature and therefore will exhibit a combination of useful properties as superconductors.

  3. Thermal aging of electrical wire jacket

    Science.gov (United States)

    Mkacher, Ines; Brument, Yves; Colin, Xavier

    2010-06-01

    The thermal degradation of high density polyethylene (PE) films, stabilized by a common commercial synergistic blend of antioxidants, were studied at 120, 140, 150 and 160° C in air under atmospheric pressure. Antioxidants depletion has been monitored by UV and FTIR spectrophotometry and induction oxidation time measurements. The peculiar shape of kinetic curves suggests that the physical loss of antioxidants cannot be neglected, but also that classical evaporation-reaction models are inadequate to predict such a kinetic behavior. A model assuming the existence of two distinct antioxidant phases in equilibrium into the PE matrix is tentatively proposed. The insoluble (dispersed) phase, corresponding to the antioxidant excess relatively to the solubility threshold, supplies in antioxidant the soluble phase, until its complete exhaustion, whereas the soluble phase evaporates and is consumed by the chemical reaction.

  4. Wire and Packing Tape Sandwiches

    Science.gov (United States)

    Rabinowitz, Sandy

    2009-01-01

    In this article, the author describes how students can combine craft wire with clear packing tape to create a two-dimensional design that can be bent and twisted to create a three-dimensional form. Students sandwich wire designs between two layers of tape. (Contains 1 online resource.)

  5. Age-related increase in Wnt inhibitor causes a senescence-like phenotype in human cardiac stem cells.

    Science.gov (United States)

    Nakamura, Tamami; Hosoyama, Tohru; Murakami, Junichi; Samura, Makoto; Ueno, Koji; Kurazumi, Hiroshi; Suzuki, Ryo; Mikamo, Akihito; Hamano, Kimikazu

    2017-06-03

    Aging of cardiac stem/progenitor cells (CSCs) impairs heart regeneration and leads to unsatisfactory outcomes of cell-based therapies. As the precise mechanisms underlying CSC aging remain unclear, the use of therapeutic strategies for elderly patients with heart failure is severely delayed. In this study, we used human cardiosphere-derived cells (CDCs), a subtype of CSC found in the postnatal heart, to identify secreted factor(s) associated with CSC aging. Human CDCs were isolated from heart failure patients of various ages (2-83 years old). Gene expression of key soluble factors was compared between CDCs derived from young and elderly patients. Among these factors, SFRP1, a gene encoding a Wnt antagonist, was significantly up-regulated in CDCs from elderly patients (≥65 years old). sFRP1 levels was increased significantly also in CDCs, whose senescent phenotype was induced by anti-cancer drug treatment. These results suggest the participation of sFRP1 in CSC aging. We show that the administration of recombinant sFRP1 induced cellular senescence in CDCs derived from young patients, as indicated by increased levels of markers such as p16, and a senescence-associated secretory phenotype. In addition, co-administration of recombinant sFRP1 could abrogate the accelerated CDC proliferation induced by Wnt3A. Taken together, our results suggest that canonical Wnt signaling and its antagonist, sFRP1, regulate proliferation of human CSCs. Furthermore, excess sFRP1 in elderly patients causes CSC aging. Copyright © 2017 Elsevier Inc. All rights reserved.

  6. Relationships of job, age, and life conditions with the causes and severity of occupational injuries in construction workers.

    Science.gov (United States)

    Chau, Nearkasen; Gauchard, Gérome C; Siegfried, Christian; Benamghar, Lahoucine; Dangelzer, Jean-Louis; Français, Martine; Jacquin, Régis; Sourdot, Alain; Perrin, Philippe P; Mur, Jean-Marie

    2004-01-01

    To assess the relationships of job, age, and life conditions with the causes and severity of occupational injuries in male construction labourers. The sample included 880 male construction workers having had at least one occupational injury with subsequent sick leave. The survey used a standardised questionnaire, filled in by the occupational physician in the presence of the subject: socio-demographic data, job, safety training, smoking habit, alcohol consumption, sporting activities, physical disabilities, hearing, vision, and sleep disorders. Statistical analysis was via the logistic regression method. Logistic models showed that falls and injuries from the handling of objects or hand tools was similar for all jobs, while masons, plumbers and electricians had a higher risk of injury from moving objects, and carpenters, roofers and civil-engineering workers were more exposed to injury from construction machinery and devices. Age falls on the same level [OR 2.04 (1.30-3.21)] and falls to a lower level [OR 1.55 (1.13-2.13)]. Injuries from the handling of objects were less frequent in overweight workers [OR 0.62 (0.46-0.84)]. Injuries with hospitalisation or sick leave > or =60 days were associated with age > or =30 and hearing disorders. The causes of injuries were related to jobs. Prevention through working conditions could be made against the revealed risks. The risks for each worker depended on age, body mass index, hearing disorders, sleep disorders, and sporting activities. The occupational physician could inform the workers of these risks and encourage them to practise sporting activities and reduce their hearing disorders and sleep disorders.

  7. The influnece of the partial single reduction on mechanical properties wires made from trip steel with 0,43 % C

    Directory of Open Access Journals (Sweden)

    S. Wiewiórowska

    2015-01-01

    Full Text Available Large strain inhomogeneity is caused by the shape of deformation zone of die and by the friction between tool and deformed wire for multistage wire drawing processes. The influence on the value of the redundant strain by the use of different partial single reductions during all wire drawing process was observed. This problem is particularly important for TRIP steel wires drawing processes because the strain intensity influences on the speed of retained austenite transformation into martensite.

  8. Wire metamaterials: physics and applications.

    Science.gov (United States)

    Simovski, Constantin R; Belov, Pavel A; Atrashchenko, Alexander V; Kivshar, Yuri S

    2012-08-16

    The physics and applications of a broad class of artificial electromagnetic materials composed of lattices of aligned metal rods embedded in a dielectric matrix are reviewed. Such structures are here termed wire metamaterials. They appear in various settings and can operate from microwaves to THz and optical frequencies. An important group of these metamaterials is a wire medium possessing extreme optical anisotropy. The study of wire metamaterials has a long history, however, most of their important and useful properties have been revealed and understood only recently, especially in the THz and optical frequency ranges where the wire media correspond to the lattices of microwires and nanowires, respectively. Another group of wire metamaterials are arrays and lattices of nanorods of noble metals whose unusual properties are driven by plasmonic resonances. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. 3D Wire 2015

    DEFF Research Database (Denmark)

    Jordi, Moréton; F, Escribano; J. L., Farias

    , therefore, we’ve drawn conclusions and recommendations for future editions of the event, also generalizable to other experiences of gamification especially in events. This report details the methodology and working elements from the design phase, human resources and organization of production......This document is a general report on the implementation of gamification in 3D Wire 2015 event. As the second gamification experience in this event, we have delved deeply in the previous objectives (attracting public areas less frequented exhibition in previous years and enhance networking) and have...... proposed new ones (viralization of the event on social networks and improvement of the integration of international attendees). On the other hand we defined a set of research objectives related to the study of gamification in an eminently social place like an event. Most of the goals have been met and...

  10. Prevalence of Eye Diseases and Causes of Visual Impairment in School-Aged Children in Western China

    Science.gov (United States)

    Pi, Lian-Hong; Chen, Lin; Liu, Qin; Ke, Ning; Fang, Jing; Zhang, Shu; Xiao, Jun; Ye, Wei-Jiang; Xiong, Yan; Shi, Hui; Zhou, Xi-Yuan; Yin, Zheng-Qin

    2012-01-01

    Background The present study investigated the prevalence of refractive error, visual impairment, and eye diseases in school-aged children in western China. Methods The survey was done in a representative county (Yongchuan District, Chongqing Municipality) of western China. Cluster random sampling was used to select children aged 6 to 15 years. We conducted door-to-door surveys and eye examinations including optometry, stereoscopic vision test, eye position and eye movement, slit lamp examination of the anterior segment, retinoscopy, and fundus examination after cycloplegia with 1% cyclopentolate. Results Among 3469 children, data were available for 3079 (88.76%). The prevalences of eye diseases were, in descending order, refractive error (20.69%; 637/3079), conjunctivitis (11.76%; 362/3079), amblyopia (1.88%; 58/3079), color vision defect (0.52%; 16/3079), keratitis (0.36%; 11/3079), strabismus (0.29%; 9/3079), cataract (0.23%; 7/3079), pathologic myopia (0.19%; 6/3079), and ocular trauma (0.13%; 4/3079). The prevalence of corneal leucoma, corneal staphyloma, optic neuropathy, macular degeneration, and myelinated nerve fibers was 0.03% (1/3079) for each. The prevalence of visual impairment was 7.70% (237/3079), and the major causes of visual impairment were uncorrected refractive error (86.08%; 204/237), amblyopia (9.70%; 23/237), pathologic myopia (1.27%; 3/237), congenital cataract (0.42%; 1/237), and others (2.11%; 5/237). Conclusions Among school-aged children in a less developed area of western China, refractive error was the most prevalent eye disorder, and uncorrected refractive error was the main cause of visual impairment. PMID:22123227

  11. Prevalence of eye diseases and causes of visual impairment in school-aged children in Western China.

    Science.gov (United States)

    Pi, Lian-Hong; Chen, Lin; Liu, Qin; Ke, Ning; Fang, Jing; Zhang, Shu; Xiao, Jun; Ye, Wei-Jiang; Xiong, Yan; Shi, Hui; Zhou, Xi-Yuan; Yin, Zheng-Qin

    2012-01-01

    The present study investigated the prevalence of refractive error, visual impairment, and eye diseases in school-aged children in western China. The survey was done in a representative county (Yongchuan District, Chongqing Municipality) of western China. Cluster random sampling was used to select children aged 6 to 15 years. We conducted door-to-door surveys and eye examinations including optometry, stereoscopic vision test, eye position and eye movement, slit lamp examination of the anterior segment, retinoscopy, and fundus examination after cycloplegia with 1% cyclopentolate. Among 3469 children, data were available for 3079 (88.76%). The prevalences of eye diseases were, in descending order, refractive error (20.69%; 637/3079), conjunctivitis (11.76%; 362/3079), amblyopia (1.88%; 58/3079), color vision defect (0.52%; 16/3079), keratitis (0.36%; 11/3079), strabismus (0.29%; 9/3079), cataract (0.23%; 7/3079), pathologic myopia (0.19%; 6/3079), and ocular trauma (0.13%; 4/3079). The prevalence of corneal leucoma, corneal staphyloma, optic neuropathy, macular degeneration, and myelinated nerve fibers was 0.03% (1/3079) for each. The prevalence of visual impairment was 7.70% (237/3079), and the major causes of visual impairment were uncorrected refractive error (86.08%; 204/237), amblyopia (9.70%; 23/237), pathologic myopia (1.27%; 3/237), congenital cataract (0.42%; 1/237), and others (2.11%; 5/237). Among school-aged children in a less developed area of western China, refractive error was the most prevalent eye disorder, and uncorrected refractive error was the main cause of visual impairment.

  12. Systolic Blood Pressure Trajectory, Frailty, and All-Cause Mortality >80 Years of Age: Cohort Study Using Electronic Health Records.

    Science.gov (United States)

    Ravindrarajah, Rathi; Hazra, Nisha C; Hamada, Shota; Charlton, Judith; Jackson, Stephen H D; Dregan, Alex; Gulliford, Martin C

    2017-06-13

    Clinical trials show benefit from lowering systolic blood pressure (SBP) in people ≥80 years of age, but nonrandomized epidemiological studies suggest lower SBP may be associated with higher mortality. This study aimed to evaluate associations of SBP with all-cause mortality by frailty category >80 years of age and to evaluate SBP trajectories before death. A population-based cohort study was conducted using electronic health records of 144 403 participants ≥80 years of age registered with family practices in the United Kingdom from 2001 to 2014. Participants were followed for ≤5 years. Clinical records of SBP were analyzed. Frailty status was classified using the e-Frailty Index into the categories of fit, mild, moderate, and severe. All-cause mortality was evaluated by frailty status and mean SBP in Cox proportional-hazards models. SBP trajectories were evaluated using person months as observations, with mean SBP and antihypertensive treatment status estimated for each person month. Fractional polynomial models were used to estimate SBP trajectories over 5 years before death. During follow-up, 51 808 deaths occurred. Mortality rates increased with frailty level and were greatest at SBP mortality was 7.7 per 100 person years at SBP 120 to 139 mm Hg, 15.2 at SBP 110 to 119 mm Hg, and 22.7 at SBP mortality may be accounted for by reverse causation if participants with lower blood pressure values are closer, on average, to the end of life. © 2017 The Authors.

  13. Load-deflection characteristics of superelastic and thermal nickel-titanium wires.

    Science.gov (United States)

    Gatto, Elda; Matarese, Giovanni; Di Bella, Guido; Nucera, Riccardo; Borsellino, Chiara; Cordasco, Giancarlo

    2013-02-01

    The aim of this study was to investigate the mechanical properties of superelastic and thermal nickel-titanium (NiTi) archwires for correct selection of orthodontic wires. Seven different NiTi wires of two different sizes (0.014 and 0.016 inches), commonly used during the alignment phase, were tested. A three-point bending test was carried out to evaluate the load-deflection characteristics. The archwires were subjected to bending at a constant temperature of 37°C and deflections of 2 and 4 mm. Analysis of variance showed that thermal NiTi wires exerted significantly lower working forces than superelastic wires of the same size in all experimental tests (P Wire size had a significant effect on the forces produced: with an increase in archwire dimension, the released strength increased for both thermal and superelastic wires. Superelastic wires showed, at a deflection of 2 mm, narrow and steep hysteresis curves in comparison with the corresponding thermal wires, which presented a wide interval between loading and unloading forces. During unloading at 4 mm of deflection, all wires showed curves with a wider plateau when compared with 2 mm deflection. Such a difference for the superelastic wires was caused by the martensite stress induced at higher deformation levels. A comprehensive understanding of mechanical characteristics of orthodontic wires is essential and selection should be undertaken in accordance with the behaviour of the different wires. It is also necessary to take into account the biomechanics used. In low-friction mechanics, thermal NiTi wires are to be preferred to superelastic wires, during the alignment phase due to their lower working forces. In conventional straightwire mechanics, a low force archwire would be unable to overcome the resistance to sliding.

  14. Age

    Science.gov (United States)

    ... Resources About Policymakers Media ASA Member Toolkit Risks Age Explore this page: Age Do anesthesia risks increase ... can you reduce anesthesia risks in older patients? Age Age may bring wisdom but it also brings ...

  15. Percutaneous Kirschner wire (K-wire) fixation for humerus shaft fractures in children: A treatment concept.

    Science.gov (United States)

    Sahu, Ramji Lal

    2013-09-01

    Fractures of the humeral shaft are uncommon, representing less than 10 percent of all fractures in children. Humeral shaft fractures in children can be treated by immobilisation alone. A small number of fractures are unable to be reduced adequately or maintained in adequate alignment, and these should be treated surgically. In the present study, Kirschner wires (K-wire) were used to achieve a closed intramedullary fixation of humeral shaft fractures. The objective of this study was to evaluate the efficacy of intramedullary K-wires for the treatment of humeral shaft fracture in children. This prospective study was conducted in the Department of Orthopaedic surgery in M. M. Medical College from June 2005 to June 2010. Sixty-eight children with a mean age of 7.7 years (range, 2-14 years) were recruited from Emergency and out patient department having closed fracture of humerus shaft. All patients were operated under general anaesthesia. All patients were followed for 12 months. Out of 68 patients, 64 patients underwent union in 42-70 days with a mean of 56 days. Complications found in four patients who had insignificant delayed union which were united next 3 weeks. Intramedullary K-wires were removed after an average of 5 months without any complications. The results were excellent in 94.11% and good in 5% children. This technique is simple, quick to perform, safe and reliable and avoids prolonged hospitalization with good results and is economical.

  16. Causes of Early-Age Thermal Cracking of Concrete Foundation Slabs and their Reinforcement to Control the Cracking

    Science.gov (United States)

    Bilčík, Juraj; Sonnenschein, Róbert; Gažovičová, Natália

    2017-09-01

    This paper focuses on the causes and consequences of early-age cracking of mass concrete foundation slabs due to restrained volume changes. Considering the importance of water leaking through cracks in terms of the serviceability, durability and environmental impact of watertight concrete structures, emphasis is placed on the effect of temperature loads on foundation slabs. Foundation slabs are usually restrained to some degree externally or internally. To evaluate the effect of external restraints on foundation slabs, friction and interaction models are introduced. The reinforcement of concrete cannot prevent the initiation of cracking, but when cracking has occurred, it may act to reduce the spacing and width of cracks. According to EN 1992-1-1, results of calculating crack widths with local variations included in National Annexes (NAs) vary considerably. A comparison of the required reinforcement areas according to different NAs is presented.

  17. Causes of Early-Age Thermal Cracking of Concrete Foundation Slabs and their Reinforcement to Control the Cracking

    Directory of Open Access Journals (Sweden)

    Bilčík Juraj

    2017-09-01

    Full Text Available This paper focuses on the causes and consequences of early-age cracking of mass concrete foundation slabs due to restrained volume changes. Considering the importance of water leaking through cracks in terms of the serviceability, durability and environmental impact of watertight concrete structures, emphasis is placed on the effect of temperature loads on foundation slabs. Foundation slabs are usually restrained to some degree externally or internally. To evaluate the effect of external restraints on foundation slabs, friction and interaction models are introduced. The reinforcement of concrete cannot prevent the initiation of cracking, but when cracking has occurred, it may act to reduce the spacing and width of cracks. According to EN 1992-1-1, results of calculating crack widths with local variations included in National Annexes (NAs vary considerably. A comparison of the required reinforcement areas according to different NAs is presented.

  18. 49 CFR 393.28 - Wiring systems.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 5 2010-10-01 2010-10-01 false Wiring systems. 393.28 Section 393.28... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.28 Wiring systems. Electrical wiring shall be installed and maintained to conform to SAE J1292—Automobile, Truck, Truck-Tractor...

  19. Oblique incidence type resistance wire proportional position detector

    International Nuclear Information System (INIS)

    Iwatani, Kazuo

    1977-01-01

    A high resistance wire, proportional counter is being developed for the use as the position detector to be installed at the focal plane of the magnet of high resolution, reaction particle analyzer for SF cyclotron. One of the difficulties to attain the target performance is its low positional resolution in case of the oblique incidence of particles with small energy loss in the counter in case of so-called single wire proportional counter. Adopting one of the solutions, proposed by Markham et al. of Michigan State University, that processes signals by ingenious cathode read-out and makes the detector into an equivalent ''thin'' counter, a high resistance wire detector still having simple read-out has been devised. The oblique incidence effect seems to be caused by the fluctuation (Landau distribution) of particle energy loss in counter gas. As a result of some discussion on this matter, the detector having increased five resistance wires instead of single wire, and having guard wires so as to make the electric field intensity in the vicinity of the cathode weak, has been manufactured to obtain the ''thin'' counter without considerably changing the overall thickness of the counter. Signal read-out is carried out by charge division method. As a result of the test, the positional resolution of Δx=1.0 mm has been attained when incidence angle was 35 deg and the collimation of particles was about 0.5 mm diameter for protons of 50 meV. (Wakatsuki, Y.)

  20. Modeling birds on wires.

    Science.gov (United States)

    Aydoğdu, A; Frasca, P; D'Apice, C; Manzo, R; Thornton, J M; Gachomo, B; Wilson, T; Cheung, B; Tariq, U; Saidel, W; Piccoli, B

    2017-02-21

    In this paper we introduce a mathematical model to study the group dynamics of birds resting on wires. The model is agent-based and postulates attraction-repulsion forces between the interacting birds: the interactions are "topological", in the sense that they involve a given number of neighbors irrespective of their distance. The model is first mathematically analyzed and then simulated to study its main properties: we observe that the model predicts birds to be more widely spaced near the borders of each group. We compare the results from the model with experimental data, derived from the analysis of pictures of pigeons and starlings taken in New Jersey: two different image elaboration protocols allow us to establish a good agreement with the model and to quantify its main parameters. We also discuss the potential handedness of the birds, by analyzing the group organization features and the group dynamics at the arrival of new birds. Finally, we propose a more refined mathematical model that describes landing and departing birds by suitable stochastic processes. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Menopause as a potential cause for higher prevalence of low back pain in women than in age-matched men

    Directory of Open Access Journals (Sweden)

    Yi Xiang J. Wang

    2017-01-01

    Full Text Available Female sex hormones play an important role in the aetiology and pathophysiology of a variety of musculoskeletal degenerative diseases. Postmenopausal women show accelerated disc degeneration due to relative oestrogen deficiency, resulting in narrower intervertebral disc space in women than age-matched men, increased prevalence of spondylolisthesis, and increased prevalence of facet joint osteoarthritis. Postmenopausal women also show higher osteoporosis related spine fracture rate, particularly at the thoracic–lumbar junction site. I propose the concept that low back pain (LBP is more prevalent in postmenopausal women than age-matched men and is associated with the physiological changes caused by the relatively lower level of sex hormones after menopause in women. Considering hormone replacement treatment (HRT's consistent efficacy reported with menopause-associated osteoarthritis, an in-depth understanding of the role of the gonadal hormones in LBP modulation warrants further study. HRT initiated at early postmenopausal phase may be protective for recurring LBP. If this is the case, further cost–benefit analysis should be performed for optimal HRT regimen in cases of women with high risk of recurring severe LBP.

  2. Measurement of glycosaminoglycans in canine synovial fluid and its correlation with the cause of secondary osteoarthritis, age and body weight

    Directory of Open Access Journals (Sweden)

    Radka Andrysíková

    2012-01-01

    Full Text Available Glycosaminoglycans are natural components of healthy joint cartilage and they also appear in healthy synovial fluid. An increased amount of glycosaminoglycans in synovial fluid is believed to be a marker of secondary osteoarthritis, regardless of its primary cause. The aim of our study was to define the relationship between glycosaminoglycans in the synovial fluid and joint disorders, age, and body weight. The samples of synovial fluid were obtained from dogs suffering from secondary secondary osteoarthritis (n = 35 and from control dogs (n = 18; control dogs had normal body weight. The results were compared among joints of dogs with secondary osteoarthritis divided into groups according to the criteria mentioned above and control dogs. Glycosaminoglycan concentrations in synovial fluid were measured using dimethylmethylene blue assay. The lowest mean value of glycosaminoglycans in synovial fluid was measured in the control group. Significantly higher glycosaminoglycan content (P < 0.05 was found in synovial fluid isolated from obese dogs compared to control dogs. Furthermore, we observed an age-related trend, in which the highest mean values were reached either in old dogs or pups. Despite the absence of significant differences in glycosaminoglycan values among dogs suffering from various types of secondary secondary osteoarthritis, the highest mean values were measured in fragmented coronoid processus group. Our data suggest that abnormally increased body weight has an impact on glycosaminoglycan concentration in synovial fluid which may imply faster degradation and turnover of joint cartilage. Such observation has not yet been published in veterinary medicine.

  3. Topology Optimized Photonic Wire Splitters

    DEFF Research Database (Denmark)

    Frandsen, Lars Hagedorn; Borel, Peter Ingo; Jensen, Jakob Søndergaard

    2006-01-01

    Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm.......Photonic wire splitters have been designed using topology optimization. The splitters have been fabricated in silicon-on-insulator material and display broadband low-loss 3dB splitting in a bandwidth larger than 100 nm....

  4. Composite conductor containing superconductive wires

    Energy Technology Data Exchange (ETDEWEB)

    Larson, W.L.; Wong, J.

    1974-03-26

    A superconductor cable substitute made by coworking multiple rods of superconductive niobium--titanium or niobium--zirconium alloy with a common copper matrix to extend the copper and rods to form a final elongated product which has superconductive wires distributed in a reduced cross-section copper conductor with a complete metallurgical bond between the normal-conductive copper and the superconductor wires contained therein is described. The superconductor cable can be in the form of a tube.

  5. 30 CFR 75.701-4 - Grounding wires; capacity of wires.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity of wires. 75.701-4... SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Grounding § 75.701-4 Grounding wires; capacity of wires. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames...

  6. Wire Integrity Field Survey of USAF Legacy Aircraft

    Science.gov (United States)

    2003-02-01

    Reunions des specialistes des techniques de estion du cycle de vie pour vehicules aeriens vieillissants ] To order the complete compilation report, use...Mechanisms and Control. Specialists’ Meeting on Life Management Techniques for Ageing Air Vehicles [Les mecanismes vieillissants et le controle...upgrades and modifications . Aging Mechanisms All wiring systems are subject to aging during their normal service life. Aging is the progressive

  7. 1 mil gold bond wire study.

    Energy Technology Data Exchange (ETDEWEB)

    Huff, Johnathon; McLean, Michael B.; Jenkins, Mark W.; Rutherford, Brian Milne

    2013-05-01

    In microcircuit fabrication, the diameter and length of a bond wire have been shown to both affect the current versus fusing time ratio of a bond wire as well as the gap length of the fused wire. This study investigated the impact of current level on the time-to-open and gap length of 1 mil by 60 mil gold bond wires. During the experiments, constant current was provided for a control set of bond wires for 250ms, 410ms and until the wire fused; non-destructively pull-tested wires for 250ms; and notched wires. The key findings were that as the current increases, the gap length increases and 73% of the bond wires will fuse at 1.8A, and 100% of the wires fuse at 1.9A within 60ms. Due to the limited scope of experiments and limited data analyzed, further investigation is encouraged to confirm these observations.

  8. HTS Wire Development Workshop: Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    The 1994 High-Temperature Superconducting Wire Development Workshop was held on February 16--17 at the St. Petersburg Hilton and Towers in St. Petersburg, Florida. The meeting was hosted by Florida Power Corporation and sponsored by the US Department of Energy`s Superconductivity Program for Electric Power Systems. The meeting focused on recent high-temperature superconducting wire development activities in the Department of Energy`s Superconductivity Systems program. The meeting opened with a general discussion on the needs and benefits of superconductivity from a utility perspective, the US global competitiveness position, and an outlook on the overall prospects of wire development. The meeting then focused on four important technology areas: Wire characterization: issues and needs; technology for overcoming barriers: weak links and flux pinning; manufacturing issues for long wire lengths; and physical properties of HTS coils. Following in-depth presentations, working groups were formed in each technology area to discuss the most important current research and development issues. The working groups identified research areas that have the potential for greatly enhancing the wire development effort. These areas are discussed in the summary reports from each of the working groups. This document is a compilation of the workshop proceedings including all general session presentations and summary reports from the working groups.

  9. Engineering task plan and status of 241-S-106 Enraf level gauge wire break

    International Nuclear Information System (INIS)

    Moore, T.L.

    1994-09-01

    This report discusses the findings of a task team which was formed which identified the need for short-term actions to re-establish tank waste level monitoring and to permanently address wire failure. The failed wire was removed and sent to Pacific Northwest Laboratory (PNL) for analysis. It was determined that the cause of the wire failure was due to chloride ion stress corrosion cracking (SCC) of the 316 stainless steel (SS) wire. Radiation induced breakdown of the polyvinyl chloride (PVC) riser liners is suspected to be the source of the chloride ions

  10. The influence of the manufacturing method on the microstructure and drawing properties of copper wires

    International Nuclear Information System (INIS)

    Gruber, A.; Jeglitsch, F.

    1982-01-01

    Copper is the third most important common metal from production figures after iron and aluminium and is largely used as pure metal in the electroindustry mainly here in the form of wires of different sizes due to its excellent electrical properties. Therefore all factors influencing the drawing ability are very important. The following work deals with the influence of impurity measurements as well as of the microstructure on the deformation or recrystallization behaviour in manufacturing continuous casting and rolling wire and dip-forming wire, and gives a rupture cause specific to each manufacturing method in the wire drawing process. (orig.) [de

  11. Effect of ammonia on Ta filaments in the hot wire CVD process

    NARCIS (Netherlands)

    Verlaan, V.; van der Werf, C.H.M.; Oliphant, C.J.; Bakker, R.; Houweling, Z.S.; Schropp, R.E.I.

    2009-01-01

    The exposure of Ta filaments to a pure NH3 ambient in a hot wire chemical vapour deposition (HWCVD) reactor affects the resistance of the wires. For filament temperatures below 1950 °C the resistance increases over time, which is probably caused by in-diffusion of N atoms. Using the filaments in a

  12. In-situ transmission electron microscopy observation of electromigration in Au thin wires.

    Science.gov (United States)

    Murakami, Yosuke; Arita, Masashi; Hamada, Kouichi; Takahashi, Yasuo

    2012-11-01

    Electromigration of thin Au wire is studied by the use of in-situ transmission electron microscopy (TEM) techniques from the viewpoint of nanogap formation. We use a relatively wide Au wire as a starting material because the position-dependent structure change in the wire provides information of the thermal effect caused by the current flow. In-situ TEM observation, in which current measurements of the Au wire are simultaneously performed, reveals the process of the growth of voids and grains. Finally the formation of a nanogap by electromigration is observed doing with current measurements. All the results observed by in-situ TEM indicate the fact that the thermal effects or temperature increase in the wire region take an important role for the structure change caused by electromigration of Au in the wire. It is suggested that the position of the nanogap can roughly be arranged by setting the wire structure and current direction even though a relatively wide wire was used. The detailed observation by in-situ TEM also suggests that the control of heat generation in the wire makes the nanogap sharp because of the well-controlled recrystallization of Au nanowires.

  13. Developments in the Generation and Interpretation of Wire Codes (invited paper)

    International Nuclear Information System (INIS)

    Ebi, K.L.

    1999-01-01

    Three new developments in the generation and interpretation of wire codes are discussed. First, a method was developed to computer generate wire codes using data gathered from a utility database of the local distribution system and from tax assessor records. This method was used to wire code more than 250,000 residences in the greater Denver metropolitan area. There was an approximate 75% agreement with field wire coding. Other research in Denver suggests that wire codes predict some characteristics of a residence and its neighbourhood, including age, assessed value, street layout and traffic density. A third new development is the case-specular method to study the association between wire codes and childhood cancers. Recent results from applying the method to the Savitz et al and London et al studies suggest that the associations between childhood cancer and VHCC residences were strongest for residences with a backyard rather than street service drop, and for VHCC residences with LCC speculars. (author)

  14. Evaluation of spinous process wiring techniques for accidental canal penetration.

    Science.gov (United States)

    Adeolu, Augustine A; Azeez, Abiodun L

    2013-04-01

    Accidental canal penetration with attendant complications constitutes one of the reasons for abandoning the use of wires for posterior spinal fusion techniques. However, there is dearth of information on this risk when the wire is introduced through the base of spinous process as against sublaminar passage. This study was designed to evaluate hardware-related postoperative complications, especially canal penetration, in our patients who had spinal process wiring in two types of posterior wiring techniques. Patients who had either of two spinous process wiring techniques formed the population for the study. The clinical records were reviewed and the following data were extracted: Age, sex, diagnosis, operation (fusion type), preoperative neurological status, postoperative neurologic deterioration, other postoperative complication and radiologic evidence of canal encroachment. One hundred and seventy four spinous processes were instrumented in 42 patients. The age of the patients ranged from 11 to 78 years while male to female ratio was 2.5:1. Majority of the spinal wiring were for trauma (29 patients; 69.0) while the remaining were tumor (6; 14.3%), degenerative diseases (4; 9.5%) and infections (3; 7.1%). The Rogers technique was performed in 16 (38.1%) patients while 26 (61.9%) underwent Adeolu et al. technique. One patient (2.3%) had neurologic deterioration while 5 patients (11.1%) had varying type of complications from wound infection to fracture of spinous processes. There was no patient with radiological or clinical evidence of canal compromise. Spinous process wiring techniques for posterior spinal stabilization appears to be safe as demonstrated in this study.

  15. Maternal immune activation causes age- and region-specific changes in brain cytokines in offspring throughout development

    Science.gov (United States)

    Garay, Paula A.; Hsiao, Elaine Y.; Patterson, Paul H.; McAllister, A. Kimberley

    2012-01-01

    Maternal infection is a risk factor for autism spectrum disorder (ASD) and schizophrenia (SZ). Indeed, modeling this risk factor in mice through maternal immune activation (MIA) causes ASD- and SZ-like neuropathologies and behaviors in the offspring. Although MIA upregulates pro-inflammatory cytokines in the fetal brain, whether MIA leads to long-lasting changes in brain cytokines during postnatal development remains unknown. Here, we tested this possibility by measuring protein levels of 23 cytokines in the blood and three brain regions from offspring of poly(I:C)- and saline-injected mice at five postnatal ages using multiplex arrays. Most cytokines examined are present in sera and brains throughout development. MIA induces changes in the levels of many cytokines in the brains and sera of offspring in a region- and age-specific manner. These MIA-induced changes follow a few, unexpected and distinct patterns. In frontal and cingulate cortices, several, mostly pro-inflammatory, cytokines are elevated at birth, followed by decreases during periods of synaptogenesis and plasticity, and increases again in the adult. Cytokines are also altered in postnatal hippocampus, but in a pattern distinct from the other regions. The MIA-induced changes in brain cytokines do not correlate with changes in serum cytokines from the same animals. Finally, these MIA-induced cytokine changes are not accompanied by breaches in the blood-brain barrier, immune cell infiltration or increases in microglial density. Together, these data indicate that MIA leads to long-lasting, region-specific changes in brain cytokines in offspring—similar to those reported for ASD and SZ—that may alter CNS development and behavior. PMID:22841693

  16. Attribution of Causes of Weight Loss and Weight Gain to 3-Year Mortality in Older Adults : Results From the Longitudinal Aging Study Amsterdam

    NARCIS (Netherlands)

    Wijnhoven, Hanneke A. H.; van Zon, Sander K. R.; Twisk, Jos; Visser, Marjolein

    2014-01-01

    Background. Weight loss is associated with a higher mortality risk in old age, but the underlying cause may impact this association. We examined associations between causes of intentional and unintentional weight loss and weight gain and mortality. Methods. We used data of five triannual examination

  17. Attribution of Causes of Weight Loss and Weight Gain to 3-Year Mortality in Older Adults: Results From the Longitudinal Aging Study Amsterdam

    NARCIS (Netherlands)

    Wijnhoven, H.A.H.; van Zon, S.K.R.; Twisk, J.; Visser, M.

    2014-01-01

    Background: Weight loss is associated with a higher mortality risk in old age, but the underlying cause may impact this association. We examined associations between causes of intentional and unintentional weight loss and weight gain and mortality. Methods: We used data of five triannual examination

  18. Efficacy of Esthetic Retainers: Clinical Comparison between Multistranded Wires and Direct-Bond Glass Fiber-Reinforced Composite Splints

    Directory of Open Access Journals (Sweden)

    Andrea Scribante

    2011-01-01

    Full Text Available The purpose of this longitudinal prospective randomized study was to evaluate the reliability of two different types of orthodontic retainers in clinical use: a multistrand stainless steel wire and a polyethylene ribbon-reinforced resin composite. Moreover the level of satisfaction of the patient about the esthetic result was also analyzed by means of a Visual Analogue Scale (VAS. 34 patients (9 boys and 25 girls, mean age 14.3, in the finishing phase of orthodontic treatment, were selected for the study. Since splints were applied the number, cause, and date of splint failures were recorded for each single tooth over 12 months. Statistical analysis was performed using a paired -test, Kaplan Meier survival estimates, and the log-rank test. Kruskal Wallis test was performed to analyze VAS recordings. Differences between the bond failure rates were not statistically significant. Esthetic result of VAS was significantly higher for polyethylene ribbon-reinforced resin retainers than for stainless steel wires.

  19. Effect of vitamin A supplementation on cause-specific mortality in women of reproductive age in Ghana: a secondary analysis from the ObaapaVitA trial

    NARCIS (Netherlands)

    Hurt, Lisa; ten Asbroek, Augustinus; Amenga-Etego, Seeba; Zandoh, Charles; Danso, Samuel; Edmond, Karen; Hurt, Chris; Tawiah, Charlotte; Hill, Zelee; Fenty, Justin; Owusu-Agyei, Seth; Campbell, Oona M.; Kirkwood, Betty R.

    2013-01-01

    To determine the effect of weekly low-dose vitamin A supplementation on cause-specific mortality in women of reproductive age in Ghana. A cluster-randomized, triple-blind, placebo-controlled trial was conducted in seven districts of the Brong Ahafo region of Ghana. Women aged 15-45 years who were

  20. Molecular epidemiology of Rotavirus causing diarrhea among children less than five years of age visiting national level children hospitals, Nepal.

    Science.gov (United States)

    Dhital, Subhash; Sherchand, Jeevan Bahadur; Pokhrel, Bharat Mani; Parajuli, Keshab; Shah, Niranjan; Mishra, Shyam Kumar; Sharma, Sangita; Kattel, Hari Prasad; Khadka, Sundar; Khatiwada, Sulochana; Parajuli, Narayan; Rijal, Basistha

    2017-04-07

    Rotaviruses are the major cause of diarrhea among the infants and young children all over the world causing over 500,000 deaths and 2.4 million hospitalizations each year. In Nepal Rotavirus infection positivity rates ranges from 17.0 to 39.0% among children less than 5 years. However, little is known about the molecular genotypes of Rotavirus prevailing. The objective of this study was to estimate the burden of Rotavirus gastroenteritis and determine the genotypes of Rotavirus among children less than 5 years. The cross sectional study was conducted from January to November 2014 among children less than 5 years old visiting Kanti Children's Hospital and Tribhuvan University Teaching Hospital. Rotavirus antigen detection was performed by Enzyme Linked Immunosorbent Assay (ELISA) using ProSpecT Rotavirus Microplate Assay. Among the Rotavirus antigen positive samples, 59 samples were used for Rotavirus RNA extraction. Multiplex PCR was performed to identify G type comprising G1-G4, G8-G10 and G12 and P type comprising P[4], P[6], P[8], P[9], P[10], and P[11]. A total of 717 diarrheal stool samples were collected from patients ranging from 10 days to 59 months of age. Rotavirus antigen positive was found among (N = 164)22.9% of patients. The highest number of the diarrhea was seen in January. Molecular analysis of Rotavirus genotypes revealed that the predominant G-Type was G12 (36%) followed by G9 (31%), G1 (21%), G2 (8.6%). The predominant P- type was P6 (32.8%) followed by P8 (31%), P10 (14.8%), P4 (14.8%). A total of seven G/P type combinations were identified the most common being G12P [6] (35.8%), G1P [8] (15.1%), G9P [8] (15.1%). Rotavirus diarrhea is, mostly affecting children from 7 to 24 months in Nepal, mostly occurring in winter. The circulating genotypes in the country are found to be primarily unusual genotypes and predominance of G12P[6]. It is recommended to conduct genotyping of Rotavirus on large samples before starting vaccination in the

  1. Age and cause-of-death contributions to area socioeconomic, sex and remoteness differences in life expectancy in New South Wales, 2010-2012.

    Science.gov (United States)

    Stephens, Alexandre S; Blyth, Fiona; Gupta, Leena; Broome, Richard A

    2018-01-31

    To determine age group- and cause-of-death-specific contributions to area socioeconomic status (SES), sex and remoteness life expectancy inequalities. Mortality and estimated residential population data from New South Wales, Australia, over 2010-2012 was used to calculate life expectancy. Inequalities by sociodemographic groups were partitioned into age group- and cause-of-death-specific contributions. The largest contributions to SES differentials in life expectancy were observed at 60-84 years of age; for cancer, cardiovascular, endocrine and respiratory causes of death; and additionally external causes of death for males. Sex inequalities ranged from 3.6 to 5.2 years, with common causes of death such as cardiovascular disease and cancer in late adulthood (60+ years) accounting for the bulk of the differences. Smaller differences in life expectancy were observed by remoteness, with the largest contributions observed in ages 85 years and above, and for cardiovascular, mental, cancer and external causes of death. Common causes of death in late adulthood accounted for the bulk of life expectancy inequalities. Implications for public health: Development of policy and interventions aimed at addressing social determinants, such as proposed by the WHO's Global Plan of Action, are needed to help reduce sociodemographic inequalities in lifespan. © 2018 The Authors.

  2. Wire Rupture Optimization in Wire Electrical Discharge Machining using Taguchi Approach

    Directory of Open Access Journals (Sweden)

    Maher Ibrahem

    2017-01-01

    Full Text Available Wire electrical discharge machining (WEDM is one of the most important nontraditional machining process that is well-known for cutting difficult to machine materials. The wire electrode along with machining parameters control the WEDM process. This research work focuses on optimizing WEDM parameters using Taguchi technique to minimize wire rupture. Experiments have been done using the L18 orthogonal array. Each experiment is repeated three times to ensure accurate readings of the wire rupture. The statistical methods of signal to noise ratio (S/N ratio is applied to study effects of peak current, pulse width, charging time, wire speed, and wire tension on wire rupture. As a results, the peak current, pulse width, and wire tension have the most significant effect on wire rupture followed by charging time and wire speed. The developed analysis can be used in the metal cutting field to identify the optimum machining parameters for less wire rupture.

  3. Examining age-related shared variance between face cognition, vision, and self-reported physical health: a test of the common cause hypothesis for social cognition

    Science.gov (United States)

    Olderbak, Sally; Hildebrandt, Andrea; Wilhelm, Oliver

    2015-01-01

    The shared decline in cognitive abilities, sensory functions (e.g., vision and hearing), and physical health with increasing age is well documented with some research attributing this shared age-related decline to a single common cause (e.g., aging brain). We evaluate the extent to which the common cause hypothesis predicts associations between vision and physical health with social cognition abilities specifically face perception and face memory. Based on a sample of 443 adults (17–88 years old), we test a series of structural equation models, including Multiple Indicator Multiple Cause (MIMIC) models, and estimate the extent to which vision and self-reported physical health are related to face perception and face memory through a common factor, before and after controlling for their fluid cognitive component and the linear effects of age. Results suggest significant shared variance amongst these constructs, with a common factor explaining some, but not all, of the shared age-related variance. Also, we found that the relations of face perception, but not face memory, with vision and physical health could be completely explained by fluid cognition. Overall, results suggest that a single common cause explains most, but not all age-related shared variance with domain specific aging mechanisms evident. PMID:26321998

  4. Examining Age-Related Shared Variance Between Face Cognition, Vision, and Self-Reported Physical Health: A Test of the Common Cause Hypothesis for Social Cognition

    Directory of Open Access Journals (Sweden)

    Sally eOlderbak

    2015-08-01

    Full Text Available The shared decline in cognitive abilities, sensory functions (e.g., vision and hearing, and physical health with increasing age is well documented with some research attributing this shared age-related decline to a single common cause (e.g., aging brain. We evaluate the extent to which the common cause hypothesis predicts associations between vision and physical health with social cognition abilities, specifically face perception and face memory. Based on a sample of 443 adults (17 to 88 years old, we test a series of structural equation models, including Multiple Indicator Multiple Cause (MIMIC models, and estimate the extent to which vision and self-reported physical health are related to face perception and face memory through a common factor, before and after controlling for their fluid cognitive component and the linear effects of age. Results suggest significant shared variance amongst these constructs, with a common factor explaining some, but not all, of the shared age-related variance. Also, we found that the relations of face perception, but not face memory, with vision and physical health could be completely explained by fluid cognition. Overall, results suggest that a single common cause explains most, but not all age-related shared variance with domain specific aging mechanisms evident.

  5. Domain and facet personality predictors of all-cause mortality among Medicare patients aged 65 to 100.

    Science.gov (United States)

    Weiss, Alexander; Costa, Paul T

    2005-01-01

    Our objectives were to test whether Conscientiousness, the other 4 domains of the Five-Factor Model, and their facets predicted mortality in older, frail individuals. Controlling for demographic and health measures, we used Cox regression to test whether the NEO Five-Factor Inventory (NEO-FFI) Neuroticism, Extraversion, Openness to Experience, Agreeableness, and Conscientiousness domains predicted all-cause mortality over 5 years in 1076 65- to 100-year-old participants who took part in a Medicare Demonstration study. Supplementary analyses on 597 participants aged 66 to 102 who were reassessed 2 years later were conducted to determine whether any of the Revised NEO Personality Inventory (NEO-PI-R) facets were related to mortality. When personality domains were treated as continuous variables, NEO-FFI Neuroticism and Agreeableness were significant protective factors. When personality domains were trichotomized, NEO-FFI Conscientiousness was a protective factor. In a third analysis, Agreeableness was not a significant predictor in a model that included the continuous Neuroticism and trichotomized Conscientiousness variables. Analysis of the NEO-PI-R Neuroticism, Agreeableness, and Conscientiousness factors showed that Agreeableness and Conscientiousness were protective and that there was a trend for a similar effect of Neuroticism. Facet-level analyses revealed that the Impulsiveness, Straightforwardness, and Self-Discipline facets of Neuroticism, Agreeableness, and Conscientiousness, respectively, were prospectively related to greater survival over a 3-year interval. The effects of Neuroticism and Agreeableness on mortality are inconsistent across previous studies. This study indicates that, in a sample of older, frail participants, high Neuroticism and Agreeableness scores are protective and that more specific effects are primarily the result of the Impulsiveness and Straightforwardness facet scales. The Conscientiousness findings are consistent with those in

  6. Enhancing wire-composite bond strength of bonded retainers with wire surface treatment.

    Science.gov (United States)

    Oesterle, L J; Shellhart, W C; Henderson, S

    2001-06-01

    Bonded orthodontic retainers with wires embedded in composite resin are commonly used for orthodontic retention. The purpose of this study was to test, in vitro, various wire surface treatments to determine the optimal method of enhancing the wire-composite bond strength. Coaxial wires and stainless steel wires with different surface treatments were bonded to bovine enamel and then pulled along their long axes with an Instron universal testing machine. Wire surface treatments included placing a right-angle bend in the wire, microetching the wire, and treating the wire with adhesion promoters; combinations of treatments were also examined. The results demonstrated a 24-fold increase in the wire-composite bond strength of wire that was microetched (sandblasted), compared with that of untreated straight wire. The difference between the amount of force required to break the bond produced by microetching alone (246.1 +/- 46.0 MPa) and that required for the bonds produced by the retentive bend (87.8 +/- 16.3 MPa), the adhesion promoters (silane, 11.0 +/- 3.1 MPa; Metal Primer, 28.5 +/- 15.8 MPa), or for any combination of surface treatments, was statistically significant. Microetching a stainless steel wire produced a higher wire-composite bond strength than that obtained from a coaxial wire (113.5 +/- 27.5 MPa). The results of this study indicate that microetching or sandblasting a stainless steel wire significantly increases the strength of the wire-composite bond.

  7. Development of Lightning-Resistant Overhead Ground Wire for Large-size Transmission Lines

    Science.gov (United States)

    Taniguchi, Sakae; Nagaraki, Yoshimi; Takami, Jun; Okabe, Shigemitsu; Saito, Toshiyuki; Nagano, Koji; Goda, Yutaka

    The overhead ground wire of AC 150mm2 is applied for the large-size transmission lines. According to inspections of transmission lines, melted component wires of AC 150mm2 have been found in some parts of 500kV transmission lines and it is obvious that the damages have been caused by lightning. Hence, the authors have developed lightning-resistant overhead ground wires as well as being evaluated lightning-resistant performance of the conventional AC 150mm2. In the paper, firstly, it is reported on the lightning performance of the conventional AC 150mm2 resulting from a DC arc test which is considered the polarity of currents and injected current waveforms for summer and winter lightning. As a result, the least amount of electric charges which can melt the components of the conventional wire was 180C. Then, the paper outlines the improvement of lightning performance of the overhead ground wire. Some kinds of developed ground wires as a trial piece have been proposed and tested, and here presented the characteristics of two typical developed wires among them. One is coated with conductive ceramic on the outer components and the another is enlarged a diameter of outer components. Both types of the wires show the excellent lightning performance from the DC arc test, comparing with the conventional ground wire of AC 150mm2.

  8. Combination Of Aging And Dimethylhydrazine Treatment Causes An Increase In The Stem Cell Population Of Rat Colonic Crypts

    OpenAIRE

    Levi, Edi; Misra, Sandhya; Du, Jianhua; Patel, Bhaumik B.; Majumdar, Adhip P. N.

    2009-01-01

    Aging is associated with increased incidence of colon cancers. It is also becoming evident that cancer stem cells (CSC) play a vital role in the pathogenesis and prognosis of colon cancer. Recently, we reported the presence of colon cancer stem-like cells in macroscopically normal mucosa in patients with adenomatous polyps and that they increase with aging, suggesting that aging may predispose the colon to carcinogenesis. In the current study we have examined the combined effects of aging and...

  9. A projector of iridium 192 wires: motivations and preliminary studies

    International Nuclear Information System (INIS)

    Cosset, J.M.; Gerbaulet, A.; Chassagne, D.

    1979-01-01

    Though the majority of procedures involved in curietherapy with Iridium 192 wires cause very few problems concerning radiation protection, this is not true in all cases: in elderly of debilitated patients, young children, or when using special techniques (curietherapy for prostate of bladder cancers for example). In these cases, the need for frequent treatment exposes the therapists to increased doses. The projector of Iridium 192 wires was conceived in order to reduce this irradiated hazard. A simple manipulation places the radioactive wires in a lead container during treatment, and then replaces them in the right position after therapy. This apparatus appears to offer the possibility of: an almost total protection of the therapists, and thus an opportunity for enlarging the indications for curietherapy; an improved quality of treatment to the patient during the application [fr

  10. Nanoline templates for single atom wires on Si(001)

    Energy Technology Data Exchange (ETDEWEB)

    Koester, Sigrun A.; Owen, James H.G.; Bianco, Francois; Mazur, Daniel; Renner, Chrisoph [Universite de Geneve, Section Physique/DPMC, Geneve (Switzerland); Rodriguez-Prieto, Alvaro; Bowler, David R. [London Centre for Nanotechnology (LCN), University College London (United Kingdom)

    2010-07-01

    Low dimensional structures are of wide scientific and technological interest. The physics of single atom metallic wires is already described in detail by theory, but a more systematic experimental verification is still desirable. The experimental problems are mainly caused by the difficulties of growing electronically isolated wires which is necessary to test the expected properties from existing theories. Here we introduce templates on a Si(001) surface which enable the growth of self-assembled single atom wires on top of them. The main template consists of a Si reconstruction called the Haiku structure which develops underneath self-assembled Bi nanowires. By hydrogenation the Si surface can be passivated and additionally the Bi dimers are stripped off while the underlying reconstruction of the Si surface remains intact. In addition the Bi nanowire by itself can be considered as a template.

  11. Put Your Cable Wiring to the Test.

    Science.gov (United States)

    Day, C. William

    2001-01-01

    Discusses why schools and universities should use testing procedures in any wire bid specification for cable wiring and also know how experienced the installers are in testing and installing structured cabling systems. Key cabling terms are included. (GR)

  12. Novel Wiring Technologies for Aerospace Applications

    Science.gov (United States)

    Gibson, Tracy L.; Parrish, Lewis M.

    2014-01-01

    Because wire failure in aerospace vehicles could be catastrophic, smart wiring capabilities have been critical for NASA. Through the years, researchers at Kennedy Space Center (KSC) have developed technologies, expertise, and research facilities to meet this need. In addition to aerospace applications, NASA has applied its knowledge of smart wiring, including self-healing materials, to serve the aviation industry. This webinar will discuss the development efforts of several wiring technologies at KSC and provide insight into both current and future research objectives.

  13. Clinical bending of nickel titanium wires

    OpenAIRE

    Stephen Chain; Priyank Seth; Namrata Rastogi; Kenneth Tan; Mayank Gupta; Richa Singh

    2015-01-01

    Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our invento...

  14. Towards Unconventional Applications of Wire Bonding

    OpenAIRE

    Schröder, Stephan

    2018-01-01

    This thesis presents novel heterogeneous integration approaches of wire materials to fabricated and package MEMS devices by exploring unconventional applications of wire bonding technology. Wire bonding, traditionally endemic in the realm of device packaging to establish electrical die-to-package interconnections, is an attractive back-end technology, offering promising features, such as high throughput, flexibility and placement accuracy. Exploiting the advantages of state-of-the-art wire bo...

  15. Different mechanical properties in Seldinger guide wires

    Directory of Open Access Journals (Sweden)

    Wolfram Schummer

    2015-01-01

    Full Text Available Background and Aims: Most central venous catheters are placed using Seldinger guide wires. EN ISO 11070 is the guideline for testing guide wire flexing performance and tensile strength, and we can safely assume that guide wires in use meet these requirements. Unfortunately, EN ISO 11070 guidelines do not reflect the clinical requirements and we continue to see mechanical failures and their associated complications. Material and Methods: This in vitro study was performed in an accredited laboratory. With regard to flexing, we: (1 Established the minimum flexing performance needed to meet clinical requirements, (2 developed flexing performance tests which mimic clinical requirement, and (3 evaluated the mechanical properties of various guide wires relative to these requirements. With regard to tensile strength, we used the testing method prescribed in ISO 11070, but did not end the test at 5 Newton (N. We continued until the guide wire was damaged, or we reached maximum tractive force. We then did a wire-to-wire comparison. We examined two basic wire constructions, monofil and core and coil. Results: Tensile strength: All wires tested, except one, met EN ISO 11070 requirements for 5 N tensile strength. The mean of the wire types tested ranged from 15.06 N to 257.76 N. Flexing performance: None of the wires kinked. The monofil had no evidence of bending. Two core/coil wires displayed minor bending (angle 1.5°. All other wires displayed bending angles between 22.5° and 43.0°. Conclusion: We recommend that: (1 Clinicians use guide wires with high-end mechanical properties, (2 EN ISO 11070 incorporate our flexing test into their testing method, raise the flexing requirement to kink-proof, (3 and raise the tensile strength requirement to a minimum of 30 N, and (3 all manufacturers and suppliers be required to display mechanical properties of all guide wire, and guide wire kits sold.

  16. Vocational Preparation Curriculum: Electrical Wiring.

    Science.gov (United States)

    Usoro, Hogan

    This document is a curriculum guide for instructors teaching vocational preparation for electrical wiring to special needs students. The purpose of the curriculum guide is to provide minimum skills for disadvantaged and handicapped students entering the mainstream; to supplement vocational skills of those students already in a regular training…

  17. Transparency in nanophotonic quantum wires

    International Nuclear Information System (INIS)

    Singh, Mahi R

    2009-01-01

    We have studied the quantum optics of a photonic quantum nanowire doped with an ensemble of three-level nanoparticles. The wire is made from two photonic crystals A and B. Crystal A is embedded within crystal B and acts as a photonic nanowire. It is considered that the conduction band of crystal A lies below that of crystal B. As a result, photons are confined in crystal A and are reflected from crystal B. The bound states of the confined photons are calculated using the transfer matrix method. It is found that the number of bound states in the wire depends on the size of the wire and the energy difference between the conduction band extrema of crystals A and B. The absorption coefficient of the system has also been calculated using the Schroedinger equation method. It is considered that the nanoparticles interact with the photonic bound states. Numerical simulations show that when one of the resonance energies lies near the bound state, the system becomes transparent. However, when the resonance energy lies away from the bound state the crystal reverts to an absorbing state. Similarly, when the radius of the dielectric spheres is changed the location of the transparency peak is shifted. This means that the present system can be switched between two states by changing the size of the wire and the transition energy. These findings can be used to make new types of optical devices.

  18. Health care's 100 most wired.

    Science.gov (United States)

    Solovy, A; Serb, C

    1999-02-01

    They're wired all right, and America's 100 most techno-savvy hospitals and health systems share one more thing: a commitment to using technology to link with employees, patients, suppliers, and insurers. "We want to be a health care travel agency for our community," says one chief information officer. "And we see Internet technology as a key."

  19. Effect of dexmedetomidine on the stress reaction caused by sevoflurance anesthesia in school-age children with different personality characteristics

    Directory of Open Access Journals (Sweden)

    Juan Fan

    2017-02-01

    Full Text Available Objective: To observe the effect of dexmedetomidine on the stress reaction caused by sevoflurance anesthesia during the perianesthesia period in school-age children with different personality characteristics. Methods: A total of 160 children who were admitted in our hospital for transumbilical single-port laparoscopic hernia inner ring ligation were included in the study and randomized into dexmedetomidine (D group and midazolam (M group. The children were performed with Eysenck Personality Questionnaire before operation (children edition. Children were divided into the emotion group (group I and stable group (group II. The operation was performed under sevoflurance inhalation anesthesia. Patients in DI and DII groups were given 1 毺g/kg DEX, MI and MII groups were given 0.05 mg/kg midazolam, for 15 min. MAP and HR one day before operation (T0, before anesthesia induction (T1, 1 min after pneumoperitoneum establishment (T2, the time after pulling out the laryngeal mask (T3, and the time after shifting from the recovery room (T4 were recorded. A volume of 6 mL venous blood 1 d before operation and 4 h after operation was collected. Blood sugar concentration, cortisol and IL-6 levels were detected. Results: MAP at T1, T2, T3, and T4 in DI and MI groups were significantly elevated when compared with at T0. MAP at T2 and T3 in DII group was significantly elevated when compared with at T0. MAP at T2, T3, and T4 in MII group was significantly elevated when compared with at T0. When compared with DI group, MAP at T1, T2, and T3 in DII group was significantly reduced; MAP at T2, T3, and T4 in MI group was significantly elevated; MAP at T1 in MII group was significantly reduced. When compared with DII group, MAP at T2, T3, and T4 in MI and MII groups was significantly elevated. HR at T1, T2, T3, and T4 was significantly elevated when compared with at T0. When compared with DI group, HR at T1, T2, and T3 in DII group was significantly reduced; HR at each

  20. Multi-anode wire straw tube tracker

    International Nuclear Information System (INIS)

    Oh, S.H.; Ebenstein, W.L.; Wang, C.W.

    2011-01-01

    We report on a test of a straw tube detector design having several anode (sense) wires inside a straw tube. The anode wires form a circle inside the tube and are read out independently. This design could solve several shortcomings of the traditional single wire straw tube design such as double hit capability and stereo configuration.

  1. Home and School Technology: Wired versus Wireless.

    Science.gov (United States)

    Van Horn, Royal

    2001-01-01

    Presents results of informal research on smart homes and appliances, structured home wiring, whole-house audio/video distribution, hybrid cable, and wireless networks. Computer network wiring is tricky to install unless all-in-one jacketed cable is used. Wireless phones help installers avoid pre-wiring problems in homes and schools. (MLH)

  2. On the preparation of superconducting wires

    International Nuclear Information System (INIS)

    Topare, R.J.; Chinchure, A.D.; Shah, S.S.; Hadole, G.B.

    1993-01-01

    The different methods of preparation of superconducting wires have been discussed. The powder-in-tube technique is followed for the preparation of YBCO and BISCCO superconducting wires. The results are discussed. The present status of the industries in preparing the superconducting wires having the maximum J c values is discussed. (author). 30 refs., 6 figs., 2 tabs

  3. Pre-wired systems prove their worth.

    Science.gov (United States)

    2012-03-01

    The 'new generation' of modular wiring systems from Apex Wiring Solutions have been specified for two of the world's foremost teaching hospitals - the Royal London and St Bartholomew's Hospital, as part of a pounds sterling 1 billion redevelopment project, to cut electrical installation times, reduce on-site waste, and provide a pre-wired, factory-tested, power and lighting system. HEJ reports.

  4. 75 FR 4584 - Wire Decking From China

    Science.gov (United States)

    2010-01-28

    ... COMMISSION Wire Decking From China AGENCY: United States International Trade Commission. ACTION: Scheduling... retarded, by reason of subsidized and less-than-fair-value imports from China of wire decking, provided for..., producers, or exporters in China of wire decking, and that such ] products are being sold in the United...

  5. Biofilm formation on stainless steel and gold wires for bonded retainers in vitro and in vivo and their susceptibility to oral antimicrobials.

    Science.gov (United States)

    Jongsma, Marije A; Pelser, Floris D H; van der Mei, Henny C; Atema-Smit, Jelly; van de Belt-Gritter, Betsy; Busscher, Henk J; Ren, Yijin

    2013-05-01

    Bonded retainers are used in orthodontics to maintain treatment result. Retention wires are prone to biofilm formation and cause gingival recession, bleeding on probing and increased pocket depths near bonded retainers. In this study, we compare in vitro and in vivo biofilm formation on different wires used for bonded retainers and the susceptibility of in vitro biofilms to oral antimicrobials. Orthodontic wires were exposed to saliva, and in vitro biofilm formation was evaluated using plate counting and live/dead staining, together with effects of exposure to toothpaste slurry alone or followed by antimicrobial mouthrinse application. Wires were also placed intra-orally for 72 h in human volunteers and undisturbed biofilm formation was compared by plate counting and live/dead staining, as well as by denaturing gradient gel electrophoresis for compositional differences in biofilms. Single-strand wires attracted only slightly less biofilm in vitro than multi-strand wires. Biofilms on stainless steel single-strand wires however, were much more susceptible to antimicrobials from toothpaste slurries and mouthrinses than on single-strand gold wires and biofilms on multi-strand wires. Also, in vivo significantly less biofilm was found on single-strand than on multi-strand wires. Microbial composition of biofilms was more dependent on the volunteer involved than on wire type. Biofilms on single-strand stainless steel wires attract less biofilm in vitro and are more susceptible to antimicrobials than on multi-strand wires. Also in vivo, single-strand wires attract less biofilm than multi-strand ones. Use of single-strand wires is preferred over multi-strand wires, not because they attract less biofilm, but because biofilms on single-strand wires are not protected against antimicrobials as in crevices and niches as on multi-strand wires.

  6. Influences of Corrosive Sulfur on Copper Wires and Oil-Paper Insulation in Transformers

    Directory of Open Access Journals (Sweden)

    Jian Li

    2011-10-01

    Full Text Available Oil-impregnated paper is widely used in power transmission equipment as a reliable insulation. However, copper sulphide deposition on oil-paper insulation can lead to insulation failures in power transformers. This paper presents the influences of copper sulfur corrosion and copper sulphide deposition on copper wires and oil-paper insulation in power transformers. Thermal aging tests of paper-wrapped copper wires and bare copper wires in insulating oil were carried out at 130 °C and 150 °C in laboratory. The corrosive characteristics of paper-wrapped copper wires and bare copper wires were analyzed. Dielectric properties of insulation paper and insulating oil were also analyzed at different stages of the thermal aging tests using a broadband dielectric spectrometer. Experiments and analysis results show that copper sulfide deposition on surfaces of copper wires and insulation paper changes the surface structures of copper wires and insulation paper. Copper sulfur corrosion changes the dielectric properties of oil-paper insulation, and the copper sulfide deposition greatly reduces the electrical breakdown strength of oil-paper insulation. Metal passivator is capable of preventing copper wires from sulfur corrosion. The experimental results are helpful for investigations for fault diagnosis of internal insulation in power transformers.

  7. Fusarium solani causing quasi-invasive infection of the foot in an immunocompetent middle-aged man from South India

    Directory of Open Access Journals (Sweden)

    Mohan H Kudur

    2013-01-01

    Full Text Available Fusarium solani is commonly found in soil, and it is associated with infections in immunocompromised individuals. Fusaroium solani causing infection in immunocompetent adult male is rare and usually overlooked. We report a case of mycetoma caused by Fusariom solani in an immunocompetent adult male from South India.

  8. A comparison of the causes of blindness certifications in England and Wales in working age adults (16-64 years), 1999-2000 with 2009-2010.

    Science.gov (United States)

    Liew, Gerald; Michaelides, Michel; Bunce, Catey

    2014-02-12

    To report on the causes of blindness certifications in England and Wales in working age adults (16-64 years) in 2009-2010; and to compare these with figures from 1999 to 2000. Analysis of the national database of blindness certificates of vision impairment (CVIs) received by the Certifications Office. Working age (16-64 years) population of England and Wales. Number and cause of blindness certifications. The Certifications Office received 1756 CVIs for blindness from persons aged between 16 and 64 inclusive between 1 April 2009 and 31 March 2010. The main causes of blindness certifications were hereditary retinal disorders (354 certifications comprising 20.2% of the total), diabetic retinopathy/maculopathy (253 persons, 14.4%) and optic atrophy (248 persons, 14.1%). Together, these three leading causes accounted for almost 50% of all blindness certifications. Between 1 April 1999 and 31 March 2000, the leading causes of blindness certification were diabetic retinopathy/maculopathy (17.7%), hereditary retinal disorders (15.8%) and optic atrophy (10.1%). For the first time in at least five decades, diabetic retinopathy/maculopathy is no longer the leading cause of certifiable blindness among working age adults in England and Wales, having been overtaken by inherited retinal disorders. This change may be related to factors including the introduction of nationwide diabetic retinopathy screening programmes in England and Wales and improved glycaemic control. Inherited retinal disease, now representing the commonest cause of certification in the working age population, has clinical and research implications, including with respect to the provision of care/resources in the NHS and the allocation of research funding.

  9. Viral and bacterial causes of severe acute respiratory illness among children aged less than 5 years in a high malaria prevalence area of western Kenya, 2007-2010.

    Science.gov (United States)

    Feikin, Daniel R; Njenga, M Kariuki; Bigogo, Godfrey; Aura, Barrack; Aol, George; Audi, Allan; Jagero, Geoffrey; Muluare, Peter O; Gikunju, Stella; Nderitu, Leonard; Winchell, Jonas M; Schneider, Eileen; Erdman, Dean D; Oberste, M Steven; Katz, Mark A; Breiman, Robert F

    2013-01-01

    Few comprehensive data exist on the etiology of severe acute respiratory illness (SARI) among African children. From March 1, 2007 to February 28, 2010, we collected blood for culture and nasopharyngeal and oropharyngeal swabs for real-time quantitative polymerase chain reaction for 10 viruses and 3 atypical bacteria among children aged causes and pneumococcus the most likely bacterial cause. Contemporaneous controls are important for interpreting upper respiratory tract specimens.

  10. Initial arch wires for alignment of crooked teeth with fixed orthodontic braces.

    Science.gov (United States)

    Wang, Yan; Jian, Fan; Lai, Wenli; Zhao, Zhihe; Yang, Zhi; Liao, Zhengyu; Shi, Zongdao; Wu, Taixiang; Millett, Declan T; McIntyre, Grant T; Hickman, Joy

    2010-04-14

    The initial arch wire is the first arch wire to be inserted into the fixed appliance at the beginning of orthodontic treatment and is used mainly for correcting crowding and rotations of teeth. With a number of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. To identify and assess the evidence for the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (30th November 2009), CENTRAL (The Cochrane Library 2009, Issue 4), MEDLINE (1950 to 30th November 2009) and EMBASE (1980 to 30th November 2009). Reference lists of articles were also searched. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies. Randomised controlled trials (RCTs) of initial arch wires to align crooked teeth with fixed orthodontic braces were selected. Only studies involving patients with upper and/or lower full arch fixed orthodontic appliances were included. Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information. Seven RCTs, with 517 participants, provided data for this review. Among them, five trials investigated the speed of initial tooth alignment comparing: 0.016 inch ion-implanted A-NiTi wire versus 0.016 inch A-NiTi versus 0.0175 multistrand stainless steel wire; 0.016x0.022 inch medium force active M-NiTi wire versus 0.016x0.022 inch graded force active M-NiTi wire versus 0.0155 inch multistrand

  11. Clinical bending of nickel titanium wires

    Directory of Open Access Journals (Sweden)

    Stephen Chain

    2015-01-01

    Full Text Available Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our inventory but also customized the wire according to the treatment.

  12. Emittance growth due to Tevatron flying wires

    Energy Technology Data Exchange (ETDEWEB)

    Syphers, M; Eddy, Nathan

    2004-06-01

    During Tevatron injection, Flying Wires have been used to measure the transverse beam size after each transfer from the Main Injector in order to deduce the transverse emittances of the proton and antiproton beams. This amounts to 36 + 9 = 45 flies of each of 3 wire systems, with an individual wire passing through each beam bunch twice during a single ''fly''. below they estimate the emittance growth induced by the interaction of the wires with the particles during these measurements. Changes of emittance from Flying Wire measurements conducted during three recent stores are compared with the estimations.

  13. Hydraulic limitation not declining nitrogen availability causes the age-related photosynthetic decline in loblolly pine (Pinus taeda L.).

    Science.gov (United States)

    Drake, J E; Raetz, L M; Davis, S C; DeLucia, E H

    2010-10-01

    Declining net primary production (NPP) with forest age is often attributed to a corresponding decline in gross primary production (GPP). We tested two hypotheses explaining the decline of GPP in ageing stands (14-115 years old) of Pinus taeda L.: (1) increasing N limitation limits photosynthetic capacity and thus decreases GPP with increasing age; and (2) hydraulic limitations increasingly induce stomatal closure, reducing GPP with increasing age. We tested these hypotheses using measurements of foliar nitrogen, photosynthesis, sap-flow and dendroclimatological techniques. Hypothesis (1) was not supported; foliar N retranslocation did not increase and declines were not observed in foliar N, leaf area per tree or photosynthetic capacity. Hypothesis (2) was supported; declines were observed in light-saturated photosynthesis, leaf- and canopy-level stomatal conductance, concentration of CO(2) inside leaf air-spaces (corroborated by an increase in wood δ(13) C) and specific leaf area (SLA), while stomatal limitation and the ratio of sapwood area (SA) to leaf area increased. The sensitivity of radial growth to inter-annual variation in temperature and drought decreased with age, suggesting that tree water use becomes increasingly conservative with age. We conclude that hydraulic limitation increasingly limits the photosynthetic rates of ageing loblolly pine trees, possibly explaining the observed reduction of NPP. © 2010 Blackwell Publishing Ltd.

  14. The Strengthening Effect of Phase Boundaries in a Severely Plastically Deformed Ti-Al Composite Wire

    Directory of Open Access Journals (Sweden)

    Tom Marr

    2014-02-01

    Full Text Available An accumulative swaging and bundling technique is used to prepare composite wires made of Ti and an Al alloy. These wires show reasonable higher yield stresses than expected from the pure material flow curves. The additional strengthening in the composite is analyzed using nanoindentation measurements, tensile testings and investigations of the microstructure. In addition, these properties are analyzed in relation to the fracture surface of the mechanically tested wires. Additional strengthening due to the presence of phase boundaries could be verified. Indications for residual stresses are found that cause a global hardness gradient from the center to the wire rim. Finally, the yield stress of the wires are calculated based on local hardness measurements.

  15. Reduction of tensile residual stresses during the drawing process of tungsten wires

    International Nuclear Information System (INIS)

    Rodriguez Ripoll, Manel; Weygand, Sabine M.; Riedel, Hermann

    2010-01-01

    Tungsten wires are commonly used in the lighting industry as filaments for lamps. During the drawing process, the inhomogeneous deformation imparted by the drawing die causes tensile residual stresses at the wire surface in circumferential direction. These stresses have a detrimental effect for the wire because they are responsible for driving longitudinal cracks, known as splits. This work proposes two methods for reducing the residual stresses during wire drawing, namely applying an advanced die geometry and performing an inexpensive post-drawing treatment based on targeted bending operations. These two methods are analyzed with finite element simulations using material parameters obtained by mechanical tests on tungsten wires at different temperatures as input data. The computed results predict a substantial reduction of the circumferential residual stresses, thus reducing the risk of splitting.

  16. The influence of drawing speed on structure changes in high carbon steel wires

    Directory of Open Access Journals (Sweden)

    M. Suliga

    2015-01-01

    Full Text Available In the paper the influence of the drawing speed on structure changes has been assessed. The Scanning Electron Microscope investigation confirmed that for wires drawn with high total draft, exceeding 80 %, makes it impossible to clearly assess the impact of drawing technology on structural changes in the drawn wires. Thus, to assess the structural changes necessary to apply quantitative methods. On the basis of examination of the wire structure by measuring of electrical resistance, the structure changes in drawn wires has been determined. It has been shown that the increase of drawing speed, especially above 15 m/s, causes an increase in structure defect, with a decline in platelet orientation of cementite in drawn wires.

  17. Imperfection analysis of flexible pipe armor wires in compression and bending

    DEFF Research Database (Denmark)

    Østergaard, Niels Højen; Lyckegaard, Anders; Andreasen, Jens H.

    2012-01-01

    The work presented in this paper is motivated by a specific failure mode known as lateral wire buckling occurring in the tensile armor layers of flexible pipes. The tensile armor is usually constituted by two layers of initially helically wound steel wires with opposite lay directions. During pipe...... laying in ultra deep waters, a flexible pipe experiences repeated bending cycles and longitudinal compression. These loading conditions are known to impose a danger to the structural integrity of the armoring layers, if the compressive load on the pipe exceeds the total maximum compressive load carrying...... ability of the wires. This may cause the wires to buckle in the circumferential pipe direction, when these are restrained against radial deformations by adjacent layers. In the present paper, a single armoring wire modeled as a long and slender curved beam embedded in a frictionless cylinder bent...

  18. Associations of ikigai as a positive psychological factor with all-cause mortality and cause-specific mortality among middle-aged and elderly Japanese people: findings from the Japan Collaborative Cohort Study.

    Science.gov (United States)

    Tanno, Kozo; Sakata, Kiyomi; Ohsawa, Masaki; Onoda, Toshiyuki; Itai, Kazuyoshi; Yaegashi, Yumi; Tamakoshi, Akiko

    2009-07-01

    To determine whether presence of ikigai as a positive psychological factor is associated with decreased risks for all-cause and cause-specific mortality among middle-aged and elderly Japanese men and women. From 1988 to 1990, a total of 30,155 men and 43,117 women aged 40 to 79 years completed a lifestyle questionnaire including a question about ikigai. Mortality follow-up was available for a mean of 12.5 years and was classified as having occurred in the first 5 years or the subsequent follow-up period. Associations between ikigai and all-cause and cause-specific mortality were assessed using a Cox's regression model. Multivariate hazard ratios (HRs) were adjusted for age, body mass index, drinking and smoking status, physical activity, sleep duration, education, occupation, marital status, perceived mental stress, and medical history. During the follow-up period, 10,021 deaths were recorded. Men and women with ikigai had decreased risks of mortality from all causes in the long-term follow-up period; multivariate HRs (95% confidence intervals, CIs) were 0.85 (0.80-0.90) for men and 0.93 (0.86-1.00) for women. The risk of cardiovascular mortality was reduced in men with ikigai; the multivariate HR (95% CI) was 0.86 (0.76-0.97). Furthermore, men and women with ikigai had a decreased risk for mortality from external causes; multivariate HRs (95% CIs) were 0.74 (0.59-0.93) for men and 0.67 (0.51-0.88) for women. The findings suggest that a positive psychological factor such as ikigai is associated with longevity among Japanese people.

  19. Mechanical behavior of NiTi arc wires under pseudoelastic cycling and cathodically hydrogen charging

    Science.gov (United States)

    Sarraj, R.; Hassine, T.; Gamaoun, F.

    2018-01-01

    NiTi wires are mainly used to design orthodontic devices. However, they may be susceptible to a delayed fracture while they are submitted to cyclic loading with the presence of hydrogen in the oral cavity. Hydrogen may cause the embrittlement of the structure, leading to lower ductility and to a change in transformation behavior. The aim of the present study is to predict the NiTi behavior under cyclic loading with hydrogen charging. One the one hand, samples are submitted to superelastic cyclic loading, which results in investigating their performance degradations. On the other hand, after hydrogen charging, cyclic tensile aging tests are carried out on NiTi orthodontic wires at room temperature in the air. During cyclic loading, we notice that the critical stress for the martensite transformation evolves, the residual strain is accumulated in the structure and the hysteresis loop changes. Thus, via this work, we can assume that the embrittlement is due to the diffusion of hydrogen and the generation of dislocations after aging. The evolution of mechanical properties of specimens becomes more significant with hydrogen charging rather than without it.

  20. Optimization of electron beam crosslinking of wire and cable insulation

    International Nuclear Information System (INIS)

    Zimek, Z.; Przybytniak, G.; Nowicki, A.

    2011-01-01

    Complete text of publication follows. The computer simulations based on Monte Carlo method and the ModeCEB software program were carried out in connection with EB radiation set-up for crosslinking of electrical wire and cable insulation, located at the Center for Radiation Research and Technology of the Institute of Nuclear Chemistry and Technology. The theoretical predictions for absorbed dose distribution in irradiated electrical wire and cable insulation caused by scanned EB were compared to the experimental results of irradiation which were carried out in the experimental set-up based on ILU 6 electron accelerator, which is characterized by the following parameters: Electron energy 0.5-2.0 MeV; Average beam current 40-10 mA, pulse duration 400 μs; Width of scanning up to 80 cm; Scan frequency up to 50 Hz. The computer simulation of the dose distributions in two-sided irradiation system by a scanned electron beam in multilayer circular objects was performed for different process parameters; electrical wire and cable geometry (thickness of insulation layers and cupper wire diameter), type of polymer isolation, electron energy, energy spread, geometry of electron beam and electrical wire and cable distribution at irradiation zone. The geometry of electron beam distribution in irradiation zone was measured using TVA and PVC foil dosimeters for electron energy range available in ILU 6 accelerator. The temperature rise of irradiated electrical wire and irradiation homogeneity were evaluated for different experimental conditions to optimize process parameters. The obtained results of computer simulation were supported by experimental data of dose distribution based on gel-fraction measurements. Such agreement indicates that computer simulation ModeCEB is correct and sufficient for modelling of absorbed dose distribution in multi-layer circular objects irradiated with scanned electron beams. Acknowledgement: The R and D activities are supported by the European

  1. Long-term smoking causes more advanced coronary endothelial dysfunction in middle-aged smokers compared to young smokers

    International Nuclear Information System (INIS)

    Naya, Masanao; Goto, Daisuke; Tsutsui, Hiroyuki; Morita, Koichi; Manabe, Osamu; Hirata, Kenji; Tamaki, Nagara; Yoshinaga, Keiichiro; Katoh, Chietsugu

    2011-01-01

    Smoking cessation has been shown to normalize the coronary endothelial dysfunction in healthy young smokers. However, its effect has not been explored in middle-aged smokers with a longer history of smoking. Therefore, we compared the effects of smoking cessation on coronary vasomotor response between both young and middle-aged smokers and identified the predictor for its improvement. This study investigated 14 young healthy smokers (age 25.2 ± 2.3 years), 13 middle-aged smokers (age 42.0 ± 6.5 years) and 10 non-smokers. Myocardial blood flow (MBF) was measured by using 15 O-water positron emission tomography (PET). At baseline, the ratio of MBF during the cold pressor test (CPT) to that at rest (MBF CPT/rest ), the index of coronary endothelial function, was significantly decreased in both young and middle-aged smokers compared to non-smokers (1.24 ± 0.20 and 1.10 ± 0.39 vs 1.53 ± 0.18, p CPT/rest at 1 month after smoking cessation significantly increased in young smokers, but not in middle-aged smokers. By multivariate analysis, baseline serum malondialdehyde-modified low-density lipoprotein (MDA-LDL) was an independent predictor for the changes in MBF CPT/rest after smoking cessation (β = -0.45, p < 0.05). Coronary endothelial dysfunction was reversible by short-term smoking cessation in young smokers, but not in middle-aged smokers, which was associated with serum MDA-LDL levels. Long-term smoking exposure could lead to more advanced coronary endothelial dysfunction and atherosclerosis possibly via oxidative stress. (orig.)

  2. Progress in American Superconductor’s HTS wire and optimization for fault current limiting systems

    Energy Technology Data Exchange (ETDEWEB)

    Malozemoff, Alexis P., E-mail: amalozemoff@amsc.com

    2016-11-15

    Highlights: • AMSC HTS wire critical current needed for rotating machinery is doubled by 16 MeV Au irradiation. • Nonuniformity of HTS wires in power devices causes hot spot formation during power system faults. • Lower normal-state resistivity and critical current lower HTS wire hot spot heating during faults. • HTS wire hot spot heating in HTS cables during faults must stay below lN{sub 2} bubble nucleation point. • HTS wire can be designed to meet hot spot heating limits in fault current limiting cables. - Abstract: American Superconductor has developed composite coated conductor tape-shaped wires using high temperature superconductor (HTS) on a flexible substrate with laminated metal stabilizer. Such wires enable many applications, each requiring specific optimization. For example, coils for HTS rotating machinery require increased current density J at 25–50 K. A collaboration with Argonne, Brookhaven and Los Alamos National Laboratories and several universities has increased J using an optimized combination of precipitates and ion irradiation defects in the HTS. Major commercial opportunities also exist to enhance electric power grid resiliency by linking substations with distribution-voltage HTS power cables [10]. Such links provide alternative power sources if one substation's transmission-voltage power is compromised. But they must also limit fault currents which would otherwise be increased by such distribution-level links. This can be done in an HTS cable, exploiting the superconductor-to-resistive transition when current exceeds the wires’ critical J. A key insight is that such transitions are usually nonuniform; so the wire must be designed to prevent localized hot spots from damaging the wire or even generating gas bubbles in the cable causing dielectric breakdown. Analysis shows that local heating can be minimized by increasing the composite tape's total thickness, decreasing its total resistance in the normal state and

  3. Sintered wire cesium dispenser photocathode

    Science.gov (United States)

    Montgomery, Eric J; Ives, R. Lawrence; Falce, Louis R

    2014-03-04

    A photoelectric cathode has a work function lowering material such as cesium placed into an enclosure which couples a thermal energy from a heater to the work function lowering material. The enclosure directs the work function lowering material in vapor form through a low diffusion layer, through a free space layer, and through a uniform porosity layer, one side of which also forms a photoelectric cathode surface. The low diffusion layer may be formed from sintered powdered metal, such as tungsten, and the uniform porosity layer may be formed from wires which are sintered together to form pores between the wires which are continuous from the a back surface to a front surface which is also the photoelectric surface.

  4. Slice of LHC dipole wiring

    CERN Multimedia

    Dipole model slice made in 1994 by Ansaldo. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. 50’000 tonnes of steel sheets are used to make the magnet yokes that keep the wiring firmly in place. The yokes constitute approximately 80% of the accelerator's weight and, placed side by side, stretch over 20 km!

  5. Repair of olecranon fractures using fiberWire without metallic implants: report of two cases

    Directory of Open Access Journals (Sweden)

    Okawa Atsushi

    2010-10-01

    Full Text Available Abstract Olecranon fractures are a common injury in fractures. The tension band technique for olecranon fractures yields good clinical outcomes; however, it is associated with significant complications. In many patients, implants irritate overlying soft tissues and cause pain. This is mostly due to protrusion of the proximal ends of the K-wires or by the twisted knots of the metal wire tension band. Below we described 2 cases of olecranon fractures treated with a unique technique using FiberWire without any metallic implants. Technically, the fragment was reduced, and two K-wires were inserted from the dorsal cortex of the distal segment to the tip of the olecranon. K-wire was exchanged for a suture retriever, and 2 strands of FiberWire were retrieved twice. Each of the two FiberWires was manually tensioned and knotted on the posterior surface of the olecranon. Bony unions could be achieved, and patients had no complaint of pain and skin irritation. There was only a small loss of flexion and extension in comparison with that of the contralateral side, and the patient did not feel inconvenienced in his daily life. Using the method described, difficulty due to K-wire or other metallic implants was avoided.

  6. Long-term smoking causes more advanced coronary endothelial dysfunction in middle-aged smokers compared to young smokers

    Energy Technology Data Exchange (ETDEWEB)

    Naya, Masanao; Goto, Daisuke; Tsutsui, Hiroyuki [Hokkaido University Graduate School of Medicine, Department of Cardiovascular Medicine, Sapporo (Japan); Morita, Koichi; Manabe, Osamu; Hirata, Kenji; Tamaki, Nagara [Hokkaido University Graduate School of Medicine, Department of Nuclear Medicine, Sapporo (Japan); Yoshinaga, Keiichiro [Hokkaido University Graduate School of Medicine, Department of Molecular Imaging, Sapporo (Japan); Katoh, Chietsugu [Hokkaido University Graduate School of Medicine, Department of Health Science, Sapporo (Japan)

    2011-03-15

    Smoking cessation has been shown to normalize the coronary endothelial dysfunction in healthy young smokers. However, its effect has not been explored in middle-aged smokers with a longer history of smoking. Therefore, we compared the effects of smoking cessation on coronary vasomotor response between both young and middle-aged smokers and identified the predictor for its improvement. This study investigated 14 young healthy smokers (age 25.2 {+-} 2.3 years), 13 middle-aged smokers (age 42.0 {+-} 6.5 years) and 10 non-smokers. Myocardial blood flow (MBF) was measured by using {sup 15}O-water positron emission tomography (PET). At baseline, the ratio of MBF during the cold pressor test (CPT) to that at rest (MBF{sub CPT/rest}), the index of coronary endothelial function, was significantly decreased in both young and middle-aged smokers compared to non-smokers (1.24 {+-} 0.20 and 1.10 {+-} 0.39 vs 1.53 {+-} 0.18, p < 0.05 and p < 0.001, respectively). The ratio of MBF during adenosine triphosphate infusion to that at rest was significantly decreased in middle-aged smokers compared to young smokers and non-smokers (3.34 {+-} 1.52 vs 4.43 {+-} 0.92 and 4.69 {+-} 1.25, p < 0.05, respectively). MBF{sub CPT/rest} at 1 month after smoking cessation significantly increased in young smokers, but not in middle-aged smokers. By multivariate analysis, baseline serum malondialdehyde-modified low-density lipoprotein (MDA-LDL) was an independent predictor for the changes in MBF{sub CPT/rest} after smoking cessation ({beta} = -0.45, p < 0.05). Coronary endothelial dysfunction was reversible by short-term smoking cessation in young smokers, but not in middle-aged smokers, which was associated with serum MDA-LDL levels. Long-term smoking exposure could lead to more advanced coronary endothelial dysfunction and atherosclerosis possibly via oxidative stress. (orig.)

  7. Wear of dragline wire ropes

    Energy Technology Data Exchange (ETDEWEB)

    Dayawansa, D.; Kuruppu, M.; Mashiri, F.; Bartosiewicz, H. [Monash University (Caulfield Campus), Caulfield East, Vic. (Australia). Department of Mechanical Engineering,

    2005-07-01

    Wire ropes are one of the most heavily used components in a dragline. Hoist ropes are subjected to fatigue due to the cyclic nature of load handling as well as due to rope bending over the sheaves and the drum under load. This leads to wire breaks due to fatigue. Accumulation of a number of wire breaks close to each other can have a detrimental effect on the rope. Furthermore, to allow for the increasing demand for higher load capacity coupled with the inconvenience of having very large ropes, the factor of safety is often compromised, which increases the wear rate. Drag ropes are also subjected to heavy loads. More importantly, they are allowed to drag along the rough mine surface subjecting them to external physical abrasion. This makes the life of drag ropes one of the lowest among those used in a dragline. Suspension and IBS ropes are relatively uniformly loaded during their regular usage although they need to withstand dynamic load cycles as well as bending. Hence they tend to last for a number of years on average. The paper analyses the wear types and their severity of each of these rope applications, and suggests methods to determine rope wear rates and the resulting rope life. The paper further gives suggestions for good operating and maintenance practice that can extend the rope life and help reduce the large expenditure associated with every major rope change in a dragline. 6 refs., 8 figs., 1 tab.

  8. Mortality in over 350,000 Insured Swedish Dogs from 1995–2000: II. Breed-Specific Age and Survival Patterns and Relative Risk for Causes of Death

    Directory of Open Access Journals (Sweden)

    Olson P

    2005-09-01

    Full Text Available Abstract This study continues analysis from a companion paper on over 350,000 insured Swedish dogs up to 10 years of age contributing to more than one million dog-years at risk during 1995–2000. The age patterns for total and diagnostic mortality and for general causes of death (trauma, tumour, locomotor, heart and neurological are presented for numerous breeds. Survival estimates at five, eight and 10 years of age are calculated. Survival to 10 years of age was 75% or more in Labrador and golden retrievers, miniature and toy poodles and miniature dachshunds and lowest in Irish wolfhounds (91% dead by 10 years. Multivariable analysis was used to estimate the relative risk for general and more specific causes of death between breeds accounting for gender and age effects, including two-way interactions. Older females had tumour as a designated cause of death more often than males in most breeds, but not in the Bernese mountain dog. Information presented in this and the companion paper inform our understanding of the population level burden of disease, and support decision-making at the population and individual level about health promotion efforts and treatment and prognosis of disease events.

  9. Clinical Efficiency of Two Sequences of Orthodontic Wires to Correct Crowding of the Lower Anterior Teeth.

    Science.gov (United States)

    Serafim, Cláudia Maria de Castro; Gurgel, Júlio de Araújo; Tiago, Carollyne Mota; Tavarez, Rudys Rodolfo de Jesus; Maia Filho, Etevaldo Matos

    2015-01-01

    This study compared time to correction of mandibular anterior crowding using two arch wire sequences, one with conventional nickel-titanium (NiTi) arch wires and the other with conventional and NiTi heat-activated arch wires. Twenty-two boys and girls (mean age: 16.68 ± 2.66) with moderate crowding (3-6 mm) were assigned randomly to one of two groups and followed up for five months (six assessments) when arch wires were changed. Time to crowding correction was analyzed statistically using the Kaplan-Meier method. Data were collected during the five-month follow-up, and time to correction was compared between groups using the log rank test. At the end of follow-up, mandibular crowding was corrected in 100% of the cases in the group treated with the sequence that included NiTi heat-activated arch wires, whereas about 30% of those treated with NiTi arch wires were not completely corrected. There was a significant difference in time to complete treatment between groups (log rank = 5.996; p wires, alignment and leveling of mandibular anterior teeth were completed earlier than in the group treated only with conventional NiTi arch wires. Clinical trial registration is found at RBR-7g5zng.

  10. Clinical Efficiency of Two Sequences of Orthodontic Wires to Correct Crowding of the Lower Anterior Teeth

    Directory of Open Access Journals (Sweden)

    Cláudia Maria de Castro Serafim

    2015-01-01

    Full Text Available This study compared time to correction of mandibular anterior crowding using two arch wire sequences, one with conventional nickel-titanium (NiTi arch wires and the other with conventional and NiTi heat-activated arch wires. Twenty-two boys and girls (mean age: 16.68 ± 2.66 with moderate crowding (3–6 mm were assigned randomly to one of two groups and followed up for five months (six assessments when arch wires were changed. Time to crowding correction was analyzed statistically using the Kaplan-Meier method. Data were collected during the five-month follow-up, and time to correction was compared between groups using the log rank test. At the end of follow-up, mandibular crowding was corrected in 100% of the cases in the group treated with the sequence that included NiTi heat-activated arch wires, whereas about 30% of those treated with NiTi arch wires were not completely corrected. There was a significant difference in time to complete treatment between groups (log rank = 5.996; p<0.05. In the group treated with the sequence that included heat-activated wires, alignment and leveling of mandibular anterior teeth were completed earlier than in the group treated only with conventional NiTi arch wires. Clinical trial registration is found at RBR-7g5zng.

  11. Overexpression of eIF-5A2 in mice causes accelerated organismal aging by increasing chromosome instability

    Directory of Open Access Journals (Sweden)

    Chen Leilei

    2011-05-01

    Full Text Available Abstract Background Amplification of 3q26 is one of the most frequent genetic alterations in many human malignancies. Recently, we isolated a novel oncogene eIF-5A2 within the 3q26 region. Functional study has demonstrated the oncogenic role of eIF-5A2 in the initiation and progression of human cancers. In the present study, we aim to investigate the physiological and pathological effect of eIF-5A2 in an eIF-5A2 transgenic mouse model. Methods An eIF-5A2 transgenic mouse model was generated using human eIF-5A2 cDNA. The eIF-5A2 transgenic mice were characterized by histological and immunohistochemistry analyses. The aging phenotypes were further characterized by wound healing, bone X-ray imaging and calcification analysis. Mouse embryo fibroblasts (MEF were isolated to further investigate molecular mechanism of eIF-5A2 in aging. Results Instead of resulting in spontaneous tumor formation, overexpression of eIF-5A2 accelerated the aging process in adult transgenic mice. This included decreased growth rate and body weight, shortened life span, kyphosis, osteoporosis, delay of wound healing and ossification. Investigation of the correlation between cellular senescence and aging showed that cellular senescence is not required for the aging phenotypes in eIF-5A2 mice. Interestingly, we found that activation of eIF-5A2 repressed p19 level and therefore destabilized p53 in transgenic mouse embryo fibroblast (MEF cells. This subsequently allowed for the accumulation of chromosomal instability, such as errors in cell dividing during metaphase and anaphase. Additionally, a significantly increase in number of aneuploidy cells (p Conclusion These observations suggest that eIF-5A2 mouse models could accelerate organismal aging by increasing chromosome instability.

  12. Intelligence in early adulthood and mortality from natural and unnatural causes in middle-aged Danish men

    DEFF Research Database (Denmark)

    Meincke, Rikke Hodal; Mortensen, Erik Lykke; Avlund, Kirsten

    2014-01-01

    High intelligence early in life has consistently been associated with decreased mortality, but the mechanisms are still not fully understood. In this cohort study, we examined the association between intelligence in early adulthood and later mortality from natural and unnatural causes taking birth...... weight, parental socioeconomic position, participants' own education and body mass index into account....

  13. Development of Phytophthora fruit rot caused by Phytophthora capsici on resistant and susceptible watermelon fruit of different ages

    Science.gov (United States)

    Watermelon is an important crop grown in 44 states in the United States. Phytophthora fruit rot caused by Phytophthora capsici is a serious disease in the southeastern U.S., where over 50% of the watermelons are produced. The disease has resulted in severe losses to watermelon growers, especially in...

  14. Modifiable causes of premature death in middle-age in Western Europe : Results from the EPIC cohort study

    NARCIS (Netherlands)

    Muller, David C.; Murphy, Neil; Johansson, Mattias; Ferrari, Pietro; Tsilidis, Konstantinos K.; Boutron-Ruault, Marie Christine; Clavel, Francoise; Dartois, Laureen; Li, Kuanrong; Kaaks, Rudolf; Weikert, Cornelia; Bergmann, Manuela; Boeing, Heiner; Tjønneland, Anne; Overvad, Kim; Redondo, M. Luisa; Agudo, Antonio; Molina-Portillo, Elena; Altzibar, Jone M.; Cirera, Lluís; Ardanaz, Eva; Khaw, Kay Tee; Wareham, Nicholas J.; Key, Timothy J.; Travis, Ruth C.; Bamia, Christina; Orfanos, Philippos; Trichopoulou, Antonia; Palli, Domenico; Pala, Valeria; Tumino, Rosario; Vineis, Paolo; Panico, Salvatore; Bueno-de-Mesquita, H. Bas; Verschuren, W. M Monique; Struijk, Ellen A.; Peeters, Petra H.; Engström, Gunnar; Melander, Olle; Sund, Malin; Weiderpass, Elisabete; Skeie, Guri; Lund, Eiliv; Norat, Teresa; Gunter, Marc; Riboli, Elio; Brennan, Paul

    2016-01-01

    Background: Life expectancy is increasing in Europe, yet a substantial proportion of adults still die prematurely before the age of 70 years. We sought to estimate the joint and relative contributions of tobacco smoking, hypertension, obesity, physical inactivity, alcohol and poor diet towards risk

  15. Age and stress as determinants of the severity of hyperthyroidism caused by Graves' disease in newly diagnosed patients

    NARCIS (Netherlands)

    Vos, Xander G.; Smit, Natalie; Endert, Erik; Brosschot, Jos F.; Tijssen, Jan G. P.; Wiersinga, Wilmar M.

    2009-01-01

    Objective: The evidence that stress may provoke Graves' hyperthyroidism in genetically susceptible subjects is substantial. Whether exposure to stress is related to the severity of thyrotoxicosis has not been studied. Advancing age is associated with not only less severe Graves' hyperthyroidism but

  16. What can long-lived mutants tell us about mechanisms causing aging and lifespan variation in natural environments?

    NARCIS (Netherlands)

    Briga, Michael; Verhulst, Simon

    2015-01-01

    Long-lived mutants of model organisms have brought remarkable progress in our understanding of aging mechanisms. However, long-lived mutants are usually maintained in optimal standardized laboratory environments (SLEs), and it is not obvious to what extent insights from long-lived mutants in SLEs

  17. Fatigue life prediction method for contact wire using maximum local stress

    International Nuclear Information System (INIS)

    Kim, Yong Seok; Haochuang, Li; Seok, Chang Sung; Koo, Jae Mean; Lee, Ki Won; Kwon, Sam Young; Cho, Yong Hyeon

    2015-01-01

    Railway contact wires supplying electricity to trains are exposed to repeated mechanical strain and stress caused by their own weight and discontinuous contact with a pantograph during train operation. Since the speed of railway transportation has increased continuously, railway industries have recently reported a number of contact wire failures caused by mechanical fatigue fractures instead of normal wear, which has been a more common failure mechanism. To secure the safety and durability of contact wires in environments with increased train speeds, a bending fatigue test on contact wire has been performed. The test equipment is too complicated to evaluate the fatigue characteristics of contact wire. Thus, the axial tension fatigue test was performed for a standard specimen, and the bending fatigue life for the contact wire structure was then predicted using the maximum local stress occurring at the top of the contact wire. Lastly, the tested bending fatigue life of the structure was compared with the fatigue life predicted by the axial tension fatigue test for verification.

  18. Fatigue life prediction method for contact wire using maximum local stress

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong Seok; Haochuang, Li; Seok, Chang Sung; Koo, Jae Mean [Sungkyunkwan University, Suwon (Korea, Republic of); Lee, Ki Won; Kwon, Sam Young; Cho, Yong Hyeon [Korea Railroad Research Institute, Uiwang (Korea, Republic of)

    2015-01-15

    Railway contact wires supplying electricity to trains are exposed to repeated mechanical strain and stress caused by their own weight and discontinuous contact with a pantograph during train operation. Since the speed of railway transportation has increased continuously, railway industries have recently reported a number of contact wire failures caused by mechanical fatigue fractures instead of normal wear, which has been a more common failure mechanism. To secure the safety and durability of contact wires in environments with increased train speeds, a bending fatigue test on contact wire has been performed. The test equipment is too complicated to evaluate the fatigue characteristics of contact wire. Thus, the axial tension fatigue test was performed for a standard specimen, and the bending fatigue life for the contact wire structure was then predicted using the maximum local stress occurring at the top of the contact wire. Lastly, the tested bending fatigue life of the structure was compared with the fatigue life predicted by the axial tension fatigue test for verification.

  19. Childhood IQ and all-cause mortality before and after age 65: prospective observational study linking the Scottish Mental Survey 1932 and the Midspan studies.

    Science.gov (United States)

    Hart, C L; Taylor, M D; Smith, G Davey; Whalley, L J; Starr, J M; Hole, D J; Wilson, V; Deary, I J

    2005-05-01

    The objective was to investigate how childhood IQ related to all-cause mortality before and after age 65. The Midspan prospective cohort studies, followed-up for mortality for 25 years, were linked to individuals' childhood IQ from the Scottish Mental Survey 1932. The Midspan studies collected data on risk factors for cardiorespiratory disease from a questionnaire and at a screening examination, and were conducted on adults in Scotland in the 1970s. An age 11 IQ from the Scottish Mental Survey 1932, a cognitive ability test conducted on 1921-born children attending schools in Scotland, was found for 938 Midspan participants. The relationship between childhood IQ and mortality risk, adjusting for adulthood socio-economic confounders, was analysed. The effect of adjustment for childhood IQ on the relationship between established risk factors (blood pressure, smoking, height and respiratory function) and mortality was also investigated. For deaths occurring up to age 65, there was a 36% increased risk per standard deviation decrease (15 points) in childhood IQ which was reduced to 29% after adjusting for social class and deprivation category. There was no statistically significant relationship between childhood IQ and deaths occurring after the age of 65. Adjustment for childhood IQ attenuated the risk factor-mortality relationship in deaths occurring up to age 65, but had no effect in deaths occurring after age 65. Childhood IQ was significantly related to deaths occurring up to age 65, but not to deaths occurring after age 65.

  20. Intelligence in early adulthood and mortality from natural and unnatural causes in middle-aged Danish men.

    Science.gov (United States)

    Meincke, Rikke Hodal; Mortensen, Erik Lykke; Avlund, Kirsten; Rosthøj, Susanne; Sørensen, Holger Jelling; Osler, Merete

    2014-02-01

    High intelligence early in life has consistently been associated with decreased mortality, but the mechanisms are still not fully understood. In this cohort study, we examined the association between intelligence in early adulthood and later mortality from natural and unnatural causes taking birth weight, parental socioeconomic position, participants' own education and body mass index into account. 13 536 Danish men born in 1953 and 1959-1961 with data from birth certificates and intelligence test scores from conscription were followed until 2009. Information on vital status was obtained from the Civil Registration System. Mortality risks were analysed by the multiple Cox proportional hazards model. The risk of mortality from natural as well as unnatural causes was more than twice as high among men in the lowest scoring intelligence tertile (HRnatural deaths=2.24; 1.90-2.65 and HRunnatural deaths=2.67; 2.03-3.53). Adjusting for all covariates attenuated the estimates, but the association remained (HRnatural deaths=1.82; 1.48-2.25 and HRunnatural deaths=2.30; 1.63-3.25). In men, intelligence in early adulthood was inversely associated with midlife mortality from natural and unnatural causes. The associations remained after adjustments for a range of covariates.

  1. Inductor Design Comparison of Three-wire and Four-wire Three-phase Voltage Source Converters in Power Factor Correction Applications

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Nymand, Morten

    2015-01-01

    This paper studies the inductor design for three-wire and four-wire power factor correction converter (PFC). Designing the efficient inductor for this converter (regardless of connecting the midpoint to the ground) requires a comprehensive knowledge of the inductor current and voltage behavior....... This paper investigates how changing three-wire PFC to four-wire counterpart influences the inductor design in terms of size, losses, and overall efficiency of the converter. Therefore, the inductor current and voltage waveforms are analyzed and generalized in both cases for one switching cycle to build...... a foundation for comparison. Accordingly, the analyses are able to interpret the differences between both configurations and explain the core losses and the copper losses of inductors, especially those caused by the high frequency ac current ripple. Finally, two inductors are designed for a 5 kW PFC...

  2. Civil Engineering Applications: Specific Properties of NiTi Thick Wires and Their Damping Capabilities, A Review

    Science.gov (United States)

    Torra, Vicenç; Martorell, Ferran; Lovey, Francisco C.; Sade, Marcos Leonel

    2017-12-01

    This study describes two investigations: first, the applicability of NiTi wires in the damping of oscillations induced by wind, rain, or traffic in cable-stayed bridges; and second, the characteristic properties of NiTi, i.e., the effects of wire diameter and particularly the effects of summer and winter temperatures and strain-aging actions on the hysteretic behavior. NiTi wires are mainly of interest because of their high number of available working cycles, reliable results, long service lifetime, and ease in obtaining sets of similar wires from the manufacturer.

  3. Egg consumption, serum cholesterol, and cause-specific and all-cause mortality: the National Integrated Project for Prospective Observation of Non-communicable Disease and Its Trends in the Aged, 1980 (NIPPON DATA80).

    Science.gov (United States)

    Nakamura, Yasuyuki; Okamura, Tomonori; Tamaki, Shinji; Kadowaki, Takashi; Hayakawa, Takehito; Kita, Yoshikuni; Okayama, Akira; Ueshima, Hirotsugu

    2004-07-01

    Because egg yolk has a high cholesterol concentration, limited egg consumption is often suggested to help prevent ischemic heart disease (IHD). We epidemiologically examined the validity of this recommendation. We analyzed the relations of egg consumption to serum cholesterol and cause-specific and all-cause mortality by using the NIPPON DATA80 (National Integrated Project for Prospective Observation of Non-communicable Disease And its Trends in the Aged, 1980) database. At the baseline examination in 1980, a nutritional survey was performed by using the food-frequency method in Japanese subjects aged > or =30 y. We followed 5186 women and 4077 men for 14 y. The subjects were categorized into 5 egg consumption groups on the basis of their responses to a questionnaire (> or =2/d, 1/d, 1/2 d, 1-2/wk, and seldom). There were 69, 1396, 1667, 1742, and 315 women in each of the 5 groups, respectively. Age-adjusted total cholesterol (5.21, 5.04, 4.95, 4.91, and 4.92 mmol/L in the 5 egg consumption categories, respectively) was related to egg consumption (P egg consumption was not related to age-adjusted total cholesterol. Cox analysis found that, in women, all-cause mortality in the 1-2-eggs/wk group was significantly lower than that in the 1-egg/d group, whereas no such relations were noted in men. Limiting egg consumption may have some health benefits, at least in women in geographic areas where egg consumption makes a relatively large contribution to total dietary cholesterol intake.

  4. Development of a new cause classification method considering plant ageing and human errors for adverse events which occurred in nuclear power plants and some results of its application

    International Nuclear Information System (INIS)

    Miyazaki, Takamasa

    2007-01-01

    The adverse events which occurred in nuclear power plants are analyzed to prevent similar events, and in the analysis of each event, the cause of the event is classified by a cause classification method. This paper shows a new cause classification method which is improved in several points as follows: (1) the whole causes are systematically classified into three major categories such as machine system, operation system and plant outside causes, (2) the causes of the operation system are classified into several management errors normally performed in a nuclear power plant, (3) the content of ageing is defined in detail for their further analysis, (4) human errors are divided and defined by the error stage, (5) human errors can be related to background factors, and so on. This new method is applied to the adverse events which occurred in domestic and overseas nuclear power plants in 2005. From these results, it is clarified that operation system errors account for about 60% of the whole causes, of which approximately 60% are maintenance errors, about 40% are worker's human errors, and that the prevention of maintenance errors, especially worker's human errors is crucial. (author)

  5. Tension band wiring for proximal femoral varus osteotomy fixation in children.

    Science.gov (United States)

    Maranho, Daniel Augusto; Pagnano, Rodrigo Gonçalves; Volpon, José Batista

    2014-08-01

    For proximal varus osteotomy of the femur in children, a stable fixation, is a concern regarding the safety and the protection of the surgery. The methods of fixation are mostly represented by plating systems; however, the tension band wiring is a simple and eligible option for fixation of proximal femur osteotomy. The purpose of this retrospective case series study is to evaluate outcomes and bone remodelation after using the tension band wiring technique to fixate proximal femoral varus osteotomies in children.The study enrolled 20 patients who underwent femoral varus osteotomy to treat Legg-Calvé-Perthes disease and other causes of necrosis of the femoral head. The mean patient age at the time of surgery was 7.4 ± 2.3 years (range, 4.3-13.8 y), and the follow-up period averaged 10 ± 4.3 years (range, 4.7-20.8 y). To assess the effects of the osteotomy at the neck-shaft angle and its evolution over time, radiographs obtained preoperatively and during the follow-up were analyzed. The neck-shaft angle was measured independently by 2 observers, and intraclass correlation coefficients (ICCs) were assessed for reliability.The ICC analysis showed good reliability. There was a significant reduction in the neck-shaft angle (P 17 years postsurgery.The tension band wiring technique proved to be a simple and effective method for fixating proximal femoral varus osteotomy in children.The level IV is appropriated for our study (case series, retrospective).

  6. Tension Band Wiring for Proximal Femoral Varus Osteotomy Fixation in Children

    Science.gov (United States)

    Maranho, Daniel Augusto; Pagnano, Rodrigo Gonçalves; Volpon, José Batista

    2014-01-01

    Abstract For proximal varus osteotomy of the femur in children, a stable fixation, is a concern regarding the safety and the protection of the surgery. The methods of fixation are mostly represented by plating systems; however, the tension band wiring is a simple and eligible option for fixation of proximal femur osteotomy. The purpose of this retrospective case series study is to evaluate outcomes and bone remodelation after using the tension band wiring technique to fixate proximal femoral varus osteotomies in children. The study enrolled 20 patients who underwent femoral varus osteotomy to treat Legg–Calvé–Perthes disease and other causes of necrosis of the femoral head. The mean patient age at the time of surgery was 7.4 ± 2.3 years (range, 4.3–13.8 y), and the follow-up period averaged 10 ± 4.3 years (range, 4.7–20.8 y). To assess the effects of the osteotomy at the neck-shaft angle and its evolution over time, radiographs obtained preoperatively and during the follow-up were analyzed. The neck-shaft angle was measured independently by 2 observers, and intraclass correlation coefficients (ICCs) were assessed for reliability. The ICC analysis showed good reliability. There was a significant reduction in the neck-shaft angle (P 17 years postsurgery. The tension band wiring technique proved to be a simple and effective method for fixating proximal femoral varus osteotomy in children. The level IV is appropriated for our study (case series, retrospective). PMID:25101990

  7. ‘A confession of ignorance’: deaths from old age and deciphering cause-of-death statistics in Scotland, 1855–1949

    Science.gov (United States)

    Reid, Alice; Garrett, Eilidh; Dibben, Chris; Williamson, Lee

    2015-01-01

    A large amount of the research undertaken in an attempt to discover the reasons underlying the late nineteenth- and early twentieth-century mortality decline in Britain has relied on the statistics published by the Registrars General. The processes by which individual causes of death are recorded and then processed in order to create the statistics are not, however, well understood. In this article, the authors build on previous work to piece together a time series of causes of death for Scotland, which removes many of the discontinuities encountered in the published statistics that result from the Registrar General deciding to update the nosology, or classification system, which was being used to compile his figures. Having regrouped individual causes of death to ‘smooth’ the time series, the authors use the new groups to examine the changing causes of death in Scotland for selected age groups, before turning to undertake a detailed examination of mortality amongst those aged 55 or more. The authors find that when deaths from ‘old age’ in the latter age group are separated from other ‘ill-defined’ causes, it becomes obvious that there was a ‘rebranding’ of cause of death. The authors then use individual-level data from two Scottish communities to further dissect the roles played by ‘informants’ and ‘doctors’ in this rebranding, in order to see how these roles may have altered over time and what the consequences might be for one's view of how mortality changed in Scotland between 1855 and 1949. Finally, the authors argue that their findings have important implications for some of historical demography's most prominent theories: the McKeown thesis and the theory of epidemiological transition. PMID:26900320

  8. Why is the gender gap in life expectancy decreasing? The impact of age- and cause-specific mortality in Sweden 1997-2014.

    Science.gov (United States)

    Sundberg, Louise; Agahi, Neda; Fritzell, Johan; Fors, Stefan

    2018-04-13

    To enhance the understanding of the current increase in life expectancy and decreasing gender gap in life expectancy. We obtained data on underlying cause of death from the National Board of Health and Welfare in Sweden for 1997 and 2014 and used Arriaga's method to decompose life expectancy by age group and 24 causes of death. Decreased mortality from ischemic heart disease had the largest impact on the increased life expectancy of both men and women and on the decreased gender gap in life expectancy. Increased mortality from Alzheimer's disease negatively influenced overall life expectancy, but because of higher female mortality, it also served to decrease the gender gap in life expectancy. The impact of other causes of death, particularly smoking-related causes, decreased in men but increased in women, also reducing the gap in life expectancy. This study shows that a focus on overall changes in life expectancies may hide important differences in age- and cause-specific mortality. It also emphasizes the importance of addressing modifiable lifestyle factors to reduce avoidable mortality.

  9. Total Physical Activity, Exercise Intensity, and Walking Speed as Predictors of All-Cause and Cause-Specific Mortality Over 7 Years in Older Men: The Concord Health and Aging in Men Project.

    Science.gov (United States)

    Hsu, Benjumin; Merom, Dafna; Blyth, Fiona M; Naganathan, Vasi; Hirani, Vasant; Le Couteur, David G; Seibel, Markus J; Waite, Louise M; Handelsman, David J; Cumming, Robert G

    2018-03-01

    The study aimed to examine the contemporaneous temporal association between changes in total physical activity, sports intensity, muscle strengthening exercise, and walking speed as predictors of all-cause, cardiovascular, cancer and other cause-specific mortality in older men. Community-dwelling men aged 70 years and older from Concord Health and Aging in Men Project were assessed at baseline (2005-2007, n = 1705), 2 years (n = 1367), and 5 years follow-up (n = 958). At all time points, Physical Activity Scale for the Elderly questionnaire, walking speed over a 6-m walk, and potential confounders were assessed. Mortality was ascertained through the state death registry with a median follow-up of 7 years. As the Physical Activity Scale for the Elderly score increased by 1 standard deviation over the follow-up period, the relative risk (RR) for mortality was 0.78 [95% confidence interval (CI) 0.69-0.88] for all-cause, 0.66 (95% CI 0.55-0.79) for cardiovascular and 0.75 (95% CI 0.61-0.94) for other cause-specific mortality, but no association was observed in cancer mortality. The RR for undertaking strenuous sports during follow-up was 0.44 (95% CI 0.26-0.72) for all-cause mortality and 0.31 (95% CI 0.13-0.70) for cancer mortality when compared with no sports participation. Increases in walking speed per standard deviation over time were also associated with a decrease in all-cause mortality (RR 0.69, 95% CI 0.61-0.78), with similar associations for cardiovascular (RR 0.60, 95% CI 0.48-0.74), but not cancer mortality. Older men who engage in strenuous sports and those who increase their walking speed over time may have lower risk of all-cause and some cause-specific mortality. Copyright © 2017 AMDA – The Society for Post-Acute and Long-Term Care Medicine. Published by Elsevier Inc. All rights reserved.

  10. Electro-mechanics of drift tube wires

    International Nuclear Information System (INIS)

    Milburn, R.H.

    1997-01-01

    The position and stability of the sense wires in very long drift tubes are affected by both gravitational and electrostatic forces, as well as by the wire tension. For a tube to be used as an element of a high-resolution detector all these forces and their effects must be understood in appropriately precise detail. In addition, the quality control procedures applied during manufacture and detector installation must be adequate to ensure that the internal wire positions remain within tolerances. It may be instructive to practitioners to review the simple theory of a taut wire in the presence of anisotropic gravitational and electrostatic fields to illustrate the conditions for stability, the equilibrium wire displacement from straightness, and the effect of the fields on the mechanical vibration frequencies. These last may be used to monitor the wire configuration externally. A number of practical formulae result and these are applied to illustrative examples. (orig.)

  11. Electromagnetic Behaviour of Metallic Wire Structures

    CERN Document Server

    Chui, S T

    2013-01-01

    Despite the recent development and interest in the photonics of metallic wire structures, the relatively simple concepts and physics often remain obscured or poorly explained to those who do not specialize in the field. Electromagnetic Behaviour of Metallic Wire Structures provides a clear and coherent guide to understanding these phenomena without excessive numerical calculations.   Including both background material and detailed derivations of the various different formulae applied, Electromagnetic Behaviour of Metallic Wire Structures describes how to extend basic circuit theory relating to voltages, currents, and resistances of metallic wire networks to include situations where the currents are no longer spatially uniform along the wire. This lays a foundation for a deeper understanding of the many new phenomena observed in meta-electromagnetic materials.   Examples of applications are included to support this new approach making Electromagnetic Behaviour of Metallic Wire Structures a comprehensive and ...

  12. Phosphorus in antique iron music wire.

    Science.gov (United States)

    Goodway, M

    1987-05-22

    Harpsichords and other wire-strung musical instruments were made with longer strings about the beginning of the 17th century. This change required stronger music wire. Although these changes coincided with the introduction of the first mass-produced steel (iron alloyed with carbon), carbon was not found in samples of antique iron harpsichord wire. The wire contained an amount of phosphorus sufficient to have impeded its conversion to steel, and may have been drawn from iron rejected for this purpose. The method used to select pig iron for wire drawing ensured the highest possible phosphorus content at a time when its presence in iron was unsuspected. Phosphorus as an alloying element has had the reputation for making steel brittle when worked cold. Nevertheless, in replicating the antique wire, it was found that lowcarbon iron that contained 0.16 percent phosphorus was easily drawn to appropriate gauges and strengths for restringing antique harpsichords.

  13. Did the Great Recession affect mortality rates in the metropolitan United States? Effects on mortality by age, gender and cause of death.

    Science.gov (United States)

    Strumpf, Erin C; Charters, Thomas J; Harper, Sam; Nandi, Arijit

    2017-09-01

    Mortality rates generally decline during economic recessions in high-income countries, however gaps remain in our understanding of the underlying mechanisms. This study estimates the impacts of increases in unemployment rates on both all-cause and cause-specific mortality across U.S. metropolitan regions during the Great Recession. We estimate the effects of economic conditions during the recent and severe recessionary period on mortality, including differences by age and gender subgroups, using fixed effects regression models. We identify a plausibly causal effect by isolating the impacts of within-metropolitan area changes in unemployment rates and controlling for common temporal trends. We aggregated vital statistics, population, and unemployment data at the area-month-year-age-gender-race level, yielding 527,040 observations across 366 metropolitan areas, 2005-2010. We estimate that a one percentage point increase in the metropolitan area unemployment rate was associated with a decrease in all-cause mortality of 3.95 deaths per 100,000 person years (95%CI -6.80 to -1.10), or 0.5%. Estimated reductions in cardiovascular disease mortality contributed 60% of the overall effect and were more pronounced among women. Motor vehicle accident mortality declined with unemployment increases, especially for men and those under age 65, as did legal intervention and homicide mortality, particularly for men and adults ages 25-64. We find suggestive evidence that increases in metropolitan area unemployment increased accidental drug poisoning deaths for both men and women ages 25-64. Our finding that all-cause mortality decreased during the Great Recession is consistent with previous studies. Some categories of cause-specific mortality, notably cardiovascular disease, also follow this pattern, and are more pronounced for certain gender and age groups. Our study also suggests that the recent recession contributed to the growth in deaths from overdoses of prescription drugs in

  14. Prevalence and causes of visual impairment according to World Health Organization and United States criteria in an aged, urban Scandinavian population

    DEFF Research Database (Denmark)

    Buch, Helena; Vinding, T; Nielsen, N V

    2001-01-01

    Organization (WHO) (VA worse than 20/60-20/400 in the better eye) and the criteria used most commonly in the United States (VA worse than 20/40 but better than 20/200 in the better eye). Eligible subjects underwent an extensive ophthalmologic examination at The National University Hospital of Denmark. MAIN...... OUTCOME MEASURES: Best-corrected VA and primary causes of visual impairment. RESULTS: The prevalence of low vision according to the WHO definition ranged from 2.6% in subjects aged 70 to 74 years to 4.8% in subjects 75 to 80 years of age, with an age-adjusted relative prevalence of 1.58%. Using the U.......S. definition, the overall age-adjusted prevalence of visual impairment was 2.9%. The causes of visual impairment according to the WHO criteria were age-related macular degeneration (AMD) (44.4%), cataract (33.3%), glaucoma in combination with cataract (11.1%), myopic macular degeneration (5.6%), and diabetic...

  15. Radiofrequency Wire Recanalization of Chronically Thrombosed TIPS

    Energy Technology Data Exchange (ETDEWEB)

    Majdalany, Bill S., E-mail: bmajdala@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States); Elliott, Eric D., E-mail: eric.elliott@osumc.edu [The Ohio State University Wexner Medical Center, Division of Interventional Radiology, Department of Radiology (United States); Michaels, Anthony J., E-mail: Anthony.michaels@osumc.edu; Hanje, A. James, E-mail: James.Hanje@osumc.edu [The Ohio State University Wexner Medical Center, Division of Gastroenterology and Hepatology, Department of Medicine (United States); Saad, Wael E. A., E-mail: wsaad@med.umich.edu [University of Michigan Health System, Division of Interventional Radiology, Department of Radiology (United States)

    2016-07-15

    Radiofrequency (RF) guide wires have been applied to cardiac interventions, recanalization of central venous thromboses, and to cross biliary occlusions. Herein, the use of a RF wire technique to revise chronically occluded transjugular intrahepatic portosystemic shunts (TIPS) is described. In both cases, conventional TIPS revision techniques failed to revise the chronically thrombosed TIPS. RF wire recanalization was successfully performed through each of the chronically thrombosed TIPS, demonstrating initial safety and feasibility in this application.

  16. IEE wiring regulations explained and illustrated

    CERN Document Server

    Scaddan, Brian

    2013-01-01

    The IEE Wiring Regulations Explained and Illustrated, Second Edition discusses the recommendations of the IEE Regulations for the Electrical Equipment of Buildings for the safe selection or erection of wiring installations. The book emphasizes earthing, bonding, protection, and circuit design of electrical wirings. The text reviews the fundamental requirements for safety, earthing systems, the earth fault loop impedance, and supplementary bonding. The book also describes the different types of protection, such as protection against mechanical damage, overcurrent, under voltage (which prevents

  17. Carbon cycle instability as a cause of the late Pleistocene ice age oscillations - Modeling the asymmetric response

    Science.gov (United States)

    Saltzman, Barry; Maasch, Kirk A.

    1988-01-01

    A dynamical model of the Pleistocene ice ages is presented, which incorporates many of the qualitative ideas advanced recently regarding the possible role of ocean circulation, chemistry, temperature, and productivity in regulating long-term atmospheric carbon dioxide variations. This model involves one additional term (and free parameter) beyond that included in a previous model (Saltzman and Sutera, 1987), providing the capacity for an asymmetric response. It is shown that many of the main features exhibited by the delta(O-18)-derived ice record and the Vostok core/delta(C-13)-derived carbon dioxide record in the late Pleistocene can be deduced as a free oscillatory solution of the model.

  18. Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL)

    Data.gov (United States)

    Federal Laboratory Consortium — Purpose:The Aircraft Wiring Support Equipment Integration Laboratory (AWSEIL) provides a variety of research, design engineering and prototype fabrication services...

  19. Memantine prevents reference and working memory impairment caused by sleep deprivation in both young and aged Octodon degus.

    Science.gov (United States)

    Tarragon, Ernesto; Lopez, Dolores; Estrada, Cristina; Gonzalez-Cuello, Ana; Ros, Carmen Ma; Lamberty, Yves; Pifferi, Fabien; Cella, Massimo; Canovi, Mara; Guiso, Giovanna; Gobbi, Marco; Fernández-Villalba, Emiliano; Blin, Olivier; Bordet, Regis; Richardson, Jill C; Herrero, María Trinidad

    2014-10-01

    Memory loss is one of the key features of cognitive impairment in either aging, Mild Cognitive Impairment (MCI) or dementia. Pharmacological treatments for memory loss are today focused on addressing symptomatology. One of these approved compounds is memantine, a partial NMDA receptor antagonist that has proved its beneficial effects in cognition. The Octodon degus (O. degus) has been recently proposed as a potential model relevant for neurodegenerative diseases. However, there are no previous studies investigating the effect of pharmacological treatments for age-related cognitive impairment in this rodent. In this work we aimed to evaluate the effect of memantine on sleep deprivation (SD)-induced memory impairment in young and old O. degus. Young and old animals were trained in different behavioral paradigms validated for memory evaluation, and randomly assigned to a control (CTL, n=14) or an SD (n=14) condition, and treated with vehicle or memantine (10-mg/Kg i.p.) before the SD started. We demonstrate that SD impairs memory in both young and old animals, although the effect in the old group was significantly more severe (Pmemories. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. LONG ELECTRIC WIRE IN URETHRA –AN UNUSUAL PARAPHILIA. CASE REPORT

    OpenAIRE

    Chattopadhyay SD; Das R; Panda N; Mahapatra RS; Biswas R; Jha A

    2011-01-01

    Introduction: Insertion of foreign body in urethra as a paraphilia is fraught with complications. Our objective was to highlight a case of long wire insertion in urethra and bladder along with its management and literature review to make emergency surgeons more aware of this type of cases. Case report: A 60 cm long wire introduced per urethra for sexual gratification got stuck inside and caused heamturia and pain. It was removed by open cystoscomy after cystoscopic removal failed. Patient als...

  1. Acidente perfurante por arame fixador de um pôster de propaganda política nas ruas do DF: relato de caso Ocular penetrating wound caused by a wire attached to a political propaganda poster on the streets of the Federal District (BR: a case report

    Directory of Open Access Journals (Sweden)

    João Luiz Pacini Costa

    2004-10-01

    Full Text Available OBJETIVO: Relatar um caso de um acidente perfurante por arame que fixava material de propaganda política exposto nas ruas do DF. MÉTODO: Relato de caso de um adolescente, sexo masculino, 16 anos, vítima de traumatismo perfurante no olho esquerdo por arame exposto que fixava propaganda eleitoral. RESULTADO: Acuidade visual de 20/25 foi obtida por implante secundário no sulco ciliar e capsulotomia posterior cirúrgica 90 dias após a perfuração ocular. CONCLUSÃO: Atentamos para a gravidade e o risco a que os cidadãos estão expostos em período de eleições devido à má fiscalização da propaganda política no Distrito Federal e a importância de leis mais rígidas na prevenção destes acidentes.PURPOSE: Report a case of ocular penetrating wound caused by a wire attached to a political propaganda poster on the streets of the DF (BR. METHODS: Case report of a teenager, male, 16-year-old. RESULTS: Visual acuity of 20/25 was obtained with a secondary intraocular lens implantation in the ciliary sulcus and a posterior surgical capsulotomy 90 days after the ocular perforation. CONCLUSION: We alert the readers about the severity and the risk that citizens are exposed to in this period of elections due to lack of safety inspection measures in the Federal District and the importance of stricter laws to prevent such accidents.

  2. FE modeling of Cu wire bond process and reliability

    NARCIS (Netherlands)

    Yuan, C.A.; Weltevreden, E.R.; Akker, P. van den; Kregting, R.; Vreugd, J. de; Zhang, G.Q.

    2011-01-01

    Copper based wire bonding technology is widely accepted by electronic packaging industry due to the world-wide cost reduction actions (compared to gold wire bond). However, the mechanical characterization of copper wire differs from the gold wire; hence the new wire bond process setting and new bond

  3. 47 CFR 76.804 - Disposition of home run wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of home run wiring. 76.804 Section... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.804 Disposition of home run wiring. (a) Building-by-building disposition of home run wiring. (1) Where an MVPD owns the home run wiring in an MDU...

  4. Gender, Age and Season as Modifiers of the Effects of Diurnal Temperature Range on Emergency Room Admissions for Cause-Specific Cardiovascular Disease among the Elderly in Beijing

    Directory of Open Access Journals (Sweden)

    Shan Zheng

    2016-04-01

    Full Text Available Background: Diurnal temperature range (DTR is an important index of climate change and variability. It is also a risk factor affecting human health. However, limited evidence is available to illustrate the effect of DTR modification on cause-specific cardiovascular disease among the elderly. Methods: A semi-parametric generalized additive model (GAM was used to analyze the exposure-effect relationship between DTR and daily emergency room (ER admissions for cause-specific cardiovascular diseases among the elderly from 2009 to 2011 in Beijing. We examined the effects of DTR for stratified groups by gender and age, and examined the effects of DTR in the warm season and cold season for cause-specific cardiovascular diseases. Results: Significant associations were found between DTR and ER admissions for all cardiovascular and cerebrovascular disease among elderly males, while DTR was significantly associated with ER admissions for all cardiovascular disease, ischemic heart disease and cerebrovascular disease among elderly females. People aged 75 years and older were more vulnerable to DTR. DTR caused greater adverse effects on both genders in the warm season, whereas the effect estimates on females were higher in cold season than in warm season. Conclusions: A short-term increase of DTR was significantly associated with ER admissions for cause-specific cardiovascular disease among the elderly in Beijing. Gender, age and season may modify the acute health effect of DTR. Some prevention programs that target the high risk subgroups in the elderly for impending large temperature changes may reduce the impact of DTR on people’s health.

  5. Intra-wire resistance and AC loss in multi-filamentary MgB2 wires

    NARCIS (Netherlands)

    Zhou, Chao; Offringa, Wietse; Bergen, Anne-Henriette; Wessel, Wilhelm A.J.; Krooshoop, Hendrikus J.G.; Dhalle, Marc M.J.; Sumption, M.D.; Collings, E.W.; Rindfleisch, M.; Tomsic, M.; ten Kate, Herman H.J.; Nijhuis, Arend

    2013-01-01

    Intra-wire resistance and AC loss of various multi-filamentary MgB2 wires with filaments surrounded by Nb barriers have been measured and analyzed. The intra-wire resistance is measured with a direct four-probe voltage–current method at various temperatures. The AC loss is acquired by both vibrating

  6. THERMO-MECHANICALLY PROCESSED ROLLED WIRE FOR HIGH-STRENGTH ON-BOARD WIRE

    Directory of Open Access Journals (Sweden)

    V. A. Lutsenko

    2011-01-01

    Full Text Available It is shown that at twisting of wire of diameter 1,83 mm, produced by direct wire drawing of thermomechanically processed rolled wire of diameter 5,5 mm of steel 90, metal stratification is completely eliminated at decrease of carbon, manganese and an additional alloying of chrome.

  7. Global rise of potential health hazards caused by blue light-induced circadian disruption in modern aging societies.

    Science.gov (United States)

    Hatori, Megumi; Gronfier, Claude; Van Gelder, Russell N; Bernstein, Paul S; Carreras, Josep; Panda, Satchidananda; Marks, Frederick; Sliney, David; Hunt, Charles E; Hirota, Tsuyoshi; Furukawa, Toshiharu; Tsubota, Kazuo

    2017-01-01

    Mammals receive light information through the eyes, which perform two major functions: image forming vision to see objects and non-image forming adaptation of physiology and behavior to light. Cone and rod photoreceptors form images and send the information via retinal ganglion cells to the brain for image reconstruction. In contrast, nonimage-forming photoresponses vary widely from adjustment of pupil diameter to adaptation of the circadian clock. nonimage-forming responses are mediated by retinal ganglion cells expressing the photopigment melanopsin. Melanopsin-expressing cells constitute 1-2% of retinal ganglion cells in the adult mammalian retina, are intrinsically photosensitive, and integrate photic information from rods and cones to control nonimage-forming adaptation. Action spectra of ipRGCs and of melanopsin photopigment peak around 480 nm blue light. Understanding melanopsin function lets us recognize considerable physiological effects of blue light, which is increasingly important in our modern society that uses light-emitting diode. Misalignment of circadian rhythmicity is observed in numerous conditions, including aging, and is thought to be involved in the development of age-related disorders, such as depression, diabetes, hypertension, obesity, and cancer. The appropriate regulation of circadian rhythmicity by proper lighting is therefore essential. This perspective introduces the potential risks of excessive blue light for human health through circadian rhythm disruption and sleep deprivation. Knowing the positive and negative aspects, this study claims the importance of being exposed to light at optimal times and intensities during the day, based on the concept of the circadian clock, ultimately to improve quality of life to have a healthy and longer life.

  8. [Socioeconomic inequalities in mortality due to all causes in the working age population of Poland in 2002 and 2011].

    Science.gov (United States)

    Pikala, Małgorzata; Maniecka-Bryła, Irena

    2017-10-17

    The aim of the study was to evaluate the influence of education, marital status, employment status and place of residence on mortality in the working age population of Poland in 2002 and 2011. All deaths of Poland's inhabitants aged 25-64, in 2002 (N = 97 004) and 2011 (N = 104 598) were analyzed. For individual socio-economic groups standardized mortality rates (SDR) per 100 000 and rate ratio (RR) were calculated. In the group of economically inactive men SDR decreased from 2244.3 in 2002 to 1781.9 in 2011, while in the group of economically active population increased from 253.8 to 298.9 (RR drop from 8.8 to 6). In the group of economically inactive women SDR decreased from 579.5 to 495.2, and among the economically active women population it increased from 78.8 to 90.9 (RR drop from 7.4 to 5.4). In the group of men with higher education SDR decreased from 285.7 to 246, while among men with primary education it increased from 1141 to 1183 (RR increase from 4 to 4.8). In the group of women with higher education SDR decreased from 127.2 to 115.6 and among women with primary education it increased from 375.8 to 423.1 (RR increase from 3 to 3.7). In the group of divorced/separated SDR also increased - from 1521.4 to 1729.8 among men and from 365.5 to 410.8 among women. Future prevention and educational programs should be addressed primarily to the population economically inactive, with primary education and those divorced/separated. Med Pr 2017;68(6):771-778. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  9. Socioeconomic inequalities in mortality due to all causes in the working age population of Poland in 2002 and 2011

    Directory of Open Access Journals (Sweden)

    Małgorzata Pikala

    2017-12-01

    Full Text Available Background: The aim of the study was to evaluate the influence of education, marital status, employment status and place of residence on mortality in the working age population of Poland in 2002 and 2011. Material and Methods: All deaths of Poland’s inhabitants aged 25–64, in 2002 (N = 97 004 and 2011 (N = 104 598 were analyzed. For individual socio-economic groups standardized mortality rates (SDR per 100 000 and rate ratio (RR were calculated. Results: In the group of economically inactive men SDR decreased from 2244.3 in 2002 to 1781.9 in 2011, while in the group of economically active population increased from 253.8 to 298.9 (RR drop from 8.8 to 6. In the group of economically inactive women SDR decreased from 579.5 to 495.2, and among the economically active women population it increased from 78.8 to 90.9 (RR drop from 7.4 to 5.4. In the group of men with higher education SDR decreased from 285.7 to 246, while among men with primary education it increased from 1141 to 1183 (RR increase from 4 to 4.8. In the group of women with higher education SDR decreased from 127.2 to 115.6 and among women with primary education it increased from 375.8 to 423.1 (RR increase from 3 to 3.7. In the group of divorced/separated SDR also increased – from 1521.4 to 1729.8 among men and from 365.5 to 410.8 among women. Conclusions: Future prevention and educational programs should be addressed primarily to the population economically inactive, with primary education and those divorced/separated. Med Pr 2017;68(6:771–778

  10. Selective deletion of cochlear hair cells causes rapid age-dependent changes in spiral ganglion and cochlear nucleus neurons.

    Science.gov (United States)

    Tong, Ling; Strong, Melissa K; Kaur, Tejbeer; Juiz, Jose M; Oesterle, Elizabeth C; Hume, Clifford; Warchol, Mark E; Palmiter, Richard D; Rubel, Edwin W

    2015-05-20

    During nervous system development, critical periods are usually defined as early periods during which manipulations dramatically change neuronal structure or function, whereas the same manipulations in mature animals have little or no effect on the same property. Neurons in the ventral cochlear nucleus (CN) are dependent on excitatory afferent input for survival during a critical period of development. Cochlear removal in young mammals and birds results in rapid death of target neurons in the CN. Cochlear removal in older animals results in little or no neuron death. However, the extent to which hair-cell-specific afferent activity prevents neuronal death in the neonatal brain is unknown. We further explore this phenomenon using a new mouse model that allows temporal control of cochlear hair cell deletion. Hair cells express the human diphtheria toxin (DT) receptor behind the Pou4f3 promoter. Injections of DT resulted in nearly complete loss of organ of Corti hair cells within 1 week of injection regardless of the age of injection. Injection of DT did not influence surrounding supporting cells directly in the sensory epithelium or spiral ganglion neurons (SGNs). Loss of hair cells in neonates resulted in rapid and profound neuronal loss in the ventral CN, but not when hair cells were eliminated at a more mature age. In addition, normal survival of SGNs was dependent on hair cell integrity early in development and less so in mature animals. This defines a previously undocumented critical period for SGN survival. Copyright © 2015 the authors 0270-6474/15/357878-14$15.00/0.

  11. A Physically Based Correction for Hot Wires in Wall Proximity

    Science.gov (United States)

    Durst, F.; Zanoun, E.-S.; Gad-El-Hak, M.

    2003-11-01

    It is common practice to calibrate hot wires in a freestream of constant and known velocity. When wires of this kind are utilized for near-wall measurements, the additional heat losses to the wall and other factors that have not been accounted for in the calibration have the potential for introducing significant errors. It is, therefore, highly desirable to find a generally applicable correction to thermal-probe measurements near walls. Following on our presentation at a previous meeting (Bul. Am. Phys. Soc. 45, no. 9, p. 141, 2000), we present herein a physically based correction for hot wires in wall proximity. As a standard, a laser Doppler velocimeter is used to provide accurate near-wall measurements of the mean velocity profile. Here the error due to the finite measuring volume of the laser is proportional to the curvature of the velocity profile, and hence is negligible in the linear and quasi-linear regions of that profile. For the flow around a hot wire near highly and moderately conducting walls, we show that the Grashof number is at least one order of magnitude less than the cube of the Reynolds number, and thus that diffusion not convection dominates the heat transfer to the wall. The universal correction curve we derive takes into account the effect of wire diameter, overheat ratio, wall thermal conductivity, wall distance, and wall thickness. In the experiments we conducted with a horizontal flat plate centrally mounted in a wind tunnel, perceptible heat loss was observed due to the shear flow on the other side of the working surface. The resulting error is caused by the change of the thermal boundary condition, and helps explain the wide scatter observed between channel flow and boundary layer experiments, particularly when using walls of poorly conducting materials.

  12. Separate vertical wiring for the fixation of comminuted fractures of the inferior pole of the patella.

    Science.gov (United States)

    Song, Hyung Keun; Yoo, Je Hyun; Byun, Young Soo; Yang, Kyu Hyun

    2014-05-01

    Among patients over 50 years of age, separate vertical wiring alone may be insufficient for fixation of fractures of the inferior pole of the patella. Therefore, mechanical and clinical studies were performed in patients over the age of 50 to test the strength of augmentation of separate vertical wiring with cerclage wire (i.e., combined technique). Multiple osteotomies were performed to create four-part fractures in the inferior poles of eight pairs of cadaveric patellae. One patella from each pair was fixed with the separate wiring technique, while the other patella was fixed with a combined technique. The ultimate load to failure and stiffness of the fixation were subsequently measured. In a clinical study of 21 patients (average age of 64 years), comminuted fractures of the inferior pole of the patellae were treated using the combined technique. Operative parameters were recorded from which post-operative outcomes were evaluated. For cadaveric patellae, whose mean age was 69 years, the mean ultimate loads to failure for the separate vertical wiring technique and the combined technique were 216.4±72.4 N and 324.9±50.6 N, respectively (p=0.012). The mean stiffness for the separate vertical wiring technique and the combined technique was 241.1±68.5 N/mm and 340.8±45.3 N/mm, respectively (p=0.012). In the clinical study, the mean clinical score at final follow-up was 28.1 points. Augmentation of separate vertical wiring with cerclage wire provides enough strength for protected early exercise of the knee joint and uneventful healing.

  13. Cause-Specific Mortality after Stroke: Relation to Age, Sex, Stroke Severity, and Risk Factors in a 10-Year Follow-Up Study

    DEFF Research Database (Denmark)

    Mogensen, UB; Olsen, TS; Andersen, KK

    2013-01-01

    We investigated cause-specific mortality in relation to age, sex, stroke severity, and cardiovascular risk factor profile in the Copenhagen Stroke Study cohort with 10 years of follow-up. In a Copenhagen community, all patients admitted to the hospital with stroke during 1992-1993 (n = 988) were...... registered on admission. Evaluation included stroke severity, computed tomography scan, and a cardiovascular risk profile. Cause of death within 10 years according to death certificate information was classified as stroke, heart/arterial disease, or nonvascular disease. Competing-risks analyses were...... after 10 years (18%). Stroke was the dominant cause of death during first year, with an absolute risk of 20.2% versus 5.2% for heart/arterial disease and 6.5% for nonvascular disease. The subsequent absolute risk of death per year was 2.8% for stroke, 4.5% for heart/arterial disease, and 5...

  14. “Goodness itself must change” – Anthroponomy in an age of socially-caused, planetary environmental change

    Directory of Open Access Journals (Sweden)

    Bendik-Keymer Jeremy David

    2016-12-01

    Full Text Available Given the reality of socially-caused, planetary-scaled, environmental change, how – if at all – should our ethical concepts change? It has been a hallmark of environmental literature in recent years to insist that they should or even must. It will be argued that, yes, our ethical concepts should change by exploring the changes needed for the core ethical concept of goodness. Goodness, it will be argued, must change to reflect a change in priority from personal intentions to the right relation between an agent and the collective to which he/she belongs. This relation, which is called herein the civic relation, centers on taking responsibility for the structure which produces unintentional, aggregate effects at the level of planetary ecology. Examples include a fossil fuel-based infrastructure, isolationist nationalism that undercuts international climate agreements to decarbonize energy, and the lack of a political forum to respect the rights of future generations. More generally, goodness according to the civic relation must express an anthroponomic orientation to life – a sustained, life-long attempt to build the practice of the collective self-regulation of humankind as a whole. Of the many consequences of this meta-ethical change in goodness, one is that it addresses the banality of evil today.

  15. Drug-eluting Ti wires with titania nanotube arrays for bone fixation and reduced bone infection

    Science.gov (United States)

    Gulati, Karan; Aw, Moom Sinn; Losic, Dusan

    2011-10-01

    Current bone fixation technology which uses stainless steel wires known as Kirschner wires for fracture fixing often causes infection and reduced skeletal load resulting in implant failure. Creating new wires with drug-eluting properties to locally deliver drugs is an appealing approach to address some of these problems. This study presents the use of titanium [Ti] wires with titania nanotube [TNT] arrays formed with a drug delivery capability to design alternative bone fixation tools for orthopaedic applications. A titania layer with an array of nanotube structures was synthesised on the surface of a Ti wire by electrochemical anodisation and loaded with antibiotic (gentamicin) used as a model of bone anti-bacterial drug. Successful fabrication of TNT structures with pore diameters of approximately 170 nm and length of 70 μm is demonstrated for the first time in the form of wires. The drug release characteristics of TNT-Ti wires were evaluated, showing a two-phase release, with a burst release (37%) and a slow release with zero-order kinetics over 11 days. These results confirmed our system's ability to be applied as a drug-eluting tool for orthopaedic applications. The established biocompatibility of TNT structures, closer modulus of elasticity to natural bones and possible inclusion of desired drugs, proteins or growth factors make this system a promising alternative to replace conventional bone implants to prevent bone infection and to be used for targeted treatment of bone cancer, osteomyelitis and other orthopaedic diseases.

  16. An Unusual Case of Nonhealing Granulomatous Keratitis Caused by Mycobacterium chelonae in a Healthy Middle Aged Adult

    Directory of Open Access Journals (Sweden)

    Vipul Bhandari

    2015-01-01

    Full Text Available Purpose. To report a rare presentation of culture positive Mycobacterium chelonae (M. chelonae corneal ulcer and its management. Case Report. We report a rare case with history of chronic pain and blurriness of vision. Examination revealed chronic nonhealing paracentral corneal ulcer inferiorly at 5 to 7 o’clock meridian with anterior chamber cells 1+ unresponsive to routine antibiotic and antifungal medications with Mantoux test (MT positivity in a middle aged nondiabetic patient with no prior obvious history of trauma, ocular surgery, and contact lens usage. Discussion. Ziehl Neelsen (ZN staining in nonhealing ulcer revealed acid fast bacilli typical of M. chelonae with subsequent culture positivity in Lowenstein Jensen (LJ medium. Subsequent treatment with topical fortified amikacin and tobramycin resulted in rapid healing of corneal ulcer. Conclusion. M. chelonae presenting as a chronic nonhealing corneal ulcer spontaneously occurring in a healthy young adult with no predisposing factor draws the need to have a good index of suspicion by performing ZN stain and culture and its subsequent successful management with topical fortified amikacin and tobramycin.

  17. Surgery-induced hippocampal angiotensin II elevation causes blood-brain barrier disruption via MMP/TIMP in aged rats

    Directory of Open Access Journals (Sweden)

    Zhengqian eLi

    2016-04-01

    Full Text Available Reversible BBB disruption has been uniformly reported in several animal models of postoperative cognitive dysfunction (POCD. Nevertheless, the precise mechanism underlying this occurrence remains unclear. Using an aged rat model of POCD, we investigated the dynamic changes in expression of molecules involved in BBB disintegration, matrix metalloproteinase-2 (MMP-2 and -9 (MMP-9, as well as three of their endogenous tissue inhibitors (TIMP-1, -2, -3, and tried to establish the correlation between MMP/TIMP balance and surgery-induced hippocampal BBB disruption. We validated the increased hippocampal expression of angiotensin II (Ang II and Ang II receptor type 1 (AT1 after surgery. We also found MMP/TIMP imbalance as early as 6 h after surgery, together with increased BBB permeability and decreased expression of Occludin and zonula occludens-1 (ZO-1, as well as increased basal lamina protein laminin at 24 h postsurgery. The AT1 antagonist candesartan restored MMP/TIMP equilibrium and modulated expression of Occludin and laminin, but not ZO-1, thereby improving BBB permeability. These events were accompanied by suppression of the surgery-induced canonical nuclear factor-κB (NF-κB activation cascade. Nevertheless, AT1 antagonism did not affect nuclear receptor peroxisome proliferator-activated receptor-γ expression. Collectively, these findings suggest that surgery-induced Ang II release impairs BBB integrity by activating NF-κB signaling and disrupting downstream MMP/TIMP balance via AT1 receptor.

  18. Short-term effect of concentrations of fine particulate matter on hospital admissions due to cardiovascular and respiratory causes among the over-75 age group in Madrid, Spain.

    Science.gov (United States)

    Linares, C; Díaz, J

    2010-01-01

    This study sought to analyse the effect of daily mean concentrations of fine particulate matter (diameter 75 years) in Madrid between 2003 and 2005. Ecological longitudinal time-series study. The dependent variable used was the daily number of emergency hospital admissions registered at the Gregorio Marañón University Teaching Hospital. The following causes were analysed: all causes [International Classification of Diseases 9th Version (ICD-9:1-799)], respiratory causes (ICD-9: 460-519) and circulatory causes (ICD-9: 390-459). Analysis focused on subjects over 75 years of age. Daily records of mean concentrations of PM(2.5), PM(10), NO(2), NO(x), SO(2) and O(3) in Madrid were used as independent variables. The control variables were seasonalities, trend, influenza epidemics, noise and pollen concentrations. Poisson regression models were constructed to calculate the relative risk (RR) and attributable risk (AR). Analyses were performed for the entire year and for the winter and summer. PM(2.5) was the single primary pollutant that proved statistically significant in all models. The functional relationship with hospital admissions was linear and had no threshold. Taking the year as a whole, the RRs among people over 75 years of age for an increase of 10 microg/m(3) in PM(2.5) concentrations were: 1.038 [95% confidence interval (CI) 1.022-1.053] for all causes at lag 0; 1.062 (95% CI 1.036-1.089) for circulatory causes at lag 0; and 1.049 (95% CI 1.019-1.078) for respiratory causes at lag 3. The ARs were 3.6%, 5.9% and 4.6%, respectively. These risks increased in winter and no statistically significant associations were observed in summer. PM(2.5) was the only primary pollutant that showed a statistically significant association with hospital admissions among people over 75 years of age in Madrid across the study period. Measures should be implemented to reduce PM(2.5) concentrations in Madrid. Copyright 2009 The Royal Society for Public Health. Published by

  19. Long-Wearing Wire Guide For Welding Torch

    Science.gov (United States)

    Gutow, David A.; Burley, Richard K.; Gilbert, Jeffrey L.; Fogel, Irving

    1992-01-01

    Insert for wire-guide tube on tungsten/inert-gas welding apparatus extends life of guide tube and increases accuracy of weld. Hardened insert resists wear by sliding tungsten wire. Chamfer guides wire into insert.

  20. 29 CFR 1919.79 - Wire rope.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Wire rope. 1919.79 Section 1919.79 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED... recommended by the equipment or the wire rope manufacturer due to actual working condition requirements. In...

  1. Automatic inspection of railway overhead wires

    NARCIS (Netherlands)

    Smorenburg, C.; Valkenburg, A.L.G. van

    1988-01-01

    For the Netherlands railway company a system for inspection of the degree of wear of the contact wires is being developed. With an active sensor the reflective under-surface of the overhead wire is illuminated with a laserbeam and reflected radiation is detected by fast CCD detectors. With the

  2. Wire compensation: Performance, SPS MDs, pulsed system

    CERN Document Server

    Dorda, U

    2008-01-01

    A wire compensation (BBLR) scheme has been proposed in order to improve the long range beam-beam performance of the nominal LHC and its phase 1 and phase 2 upgrades[1]. In this paper we present experimental experience of the CERN SPS wires (BBLR) and report on progress with the RF BBLR.

  3. WIRED magazine announces rave awards nominees

    CERN Multimedia

    2002-01-01

    WIRED Magazine has anounced the nominees for its fourth annual WIRED Rave Awards, celebrating innovation and the individuals transforming commerce and culture. Jeffrey Hangst of the University of Aarhus has been nominated in the science category, for his work on the ATHENA Experiment, CERN (1/2 page).

  4. Hot-wire anemometer for spirography.

    Science.gov (United States)

    Plakk, P; Liik, P; Kingisepp, P H

    1998-01-01

    The use of a constant temperature hot-wire anemometer flow sensor for spirography is reported. The construction, operating principles and calibration procedure of the apparatus are described, and temperature compensation method is discussed. Frequency response is studied. It is shown that this hot-wire flow transducer satisfies common demands with respect to accuracy, response time and temperature variations.

  5. Prognostic significance of mitral regurgitation in long-term all-cause mortality in patients aged ≥ 80 years with acute coronary syndrome.

    Science.gov (United States)

    Li, Shijun; Barywani, Salim; Fu, Michael

    2014-09-20

    Mitral regurgitation (MR) has been shown to be associated with a poor prognosis in the patients with acute myocardial infarction, whether or not percutaneous coronary intervention (PCI) is employed. However, the long-term prognostic significance of MR in octogenarian patients with acute coronary syndrome (ACS) remains unknown. We sought to determine the impact of MR on long-term all-cause mortality and to further reveal whether PCI could influence the prognosis in octogenarian MR patients with ACS. In this study, we included a total of 353 consecutive hospitalized patients, aged ≥ 80 years, with ACS during the period of 5-year follow-up. Association between MR and long-term all-cause mortality was analyzed both in a overall cohort and in a matched cohort developed from a propensity score analysis. MR was independently associated with long-term all-cause mortality in the overall and matched cohorts (hazard ratio (HR) 1.58, 95% CI 1.01-2.47, P=0.043; HR 1.90, 95% CI 1.15-3.13, P=0.013). In the subgroup treated with PCI, MR also exhibited higher long-term all-cause mortality, PCI remained an independent determinant of improving long-term survival rate by reducing the mortality by 15.1% in ACS patients with MR aged ≥ 80 years. Our study demonstrates that MR is independently associated with long-term all-cause mortality, and PCI is an independent determinant for improving the long-term survival rate in the octogenarian ACS patients with MR. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  6. Modified tension band wiring technique for olecranon fractures: where and how should the K-wires be inserted to avoid articular penetration?

    Science.gov (United States)

    Özsoy, Mehmet Hakan; Kızılay, Onur; Günenç, Ceren; Özsoy, Arzu; Demiryürek, Deniz; Hayran, Mutlu; Erçakmak, Burcu; Sakaoğulları, Abdurrahman

    2015-01-01

    Articular penetration of K-wires is a possible complication of the modified tension band wiring technique. However, there is no clear information or evidence regarding the entry point or introduction angle for K-wires to avoid this complication. The aim of this experimental study was to evaluate the effect of varying K-wire insertion points and angles on the risk for articular penetration during modified tension band wiring for olecranon fractures. All anatomical measurements were made on 50 cadaveric ulnas, and all other measurements were performed on exact foam replications of the 50 cadaveric ulnas. Morphometric measurements, including olecranon height and heights of the central, radial and ulnar facets of the semilunar notch, were taken. In the sagittal plane, articular angle and tubercle angle were measured. Two 1.6-mm parallel K-wires were inserted from 0, 5 and 8 mm anterior to the dorsal cortex of the olecranon process at angles of 20° and 30°. K-wire articular penetration was evaluated both visually and radiographically. The mean central, radial and ulnar heights of the semilunar notch were 17.3 mm (14.7-20.0), 16.2 mm (12.0-21.0) and 15.8 mm (13.30-20.5), respectively. We observed no articular penetration at the 0-mm level at 20° and 30° (0 mm 20° and 0 mm 30°, respectively) or at 5 mm 20°. At 8 mm 30° wire introduction, more than 64% articular penetration was observed on either facet. The sequence from least to most likely to cause articular penetration was: 0 mm = 5 mm 20° > 5 mm 30° = 8 mm 20° > 8 mm 30°. The radial height of the semilunar notch was negatively correlated to the risk of articular penetration, when the wire was introduced at 8 mm 30°, 8 mm 20° and 5 mm 30° (all pwiring technique to prevent articular penetration, K-wires should be inserted in the first 5 mm from dorsal cortex of the olecranon process at a maximum angle of 20°. Moreover, if the wires are required to be inserted more anteriorly because of the anatomical

  7. Application of hot-wire technique at unconventional conditions

    Science.gov (United States)

    Lebiga, V. A.; Pak, A. Yu.; Zinoviev, V. N.; Mironov, D. S.

    2017-10-01

    The problems of using the hot-wire method for studying fluctuations in flows are considered when standard approaches and conventional modes cannot be used due to constraints caused either by the flow parameters or by the characteristics and conditions of the experiments. Examples of measurements under conditions of extremely low pressures and beyond the limits of the continuity of the medium in the CO2-laser are given; The use of data of hot-wire measurements for the determination of sources of disturbances in test sections of high-speed wind tunnels is shown; the design of a probe for measurement of concentration of components of the binary gas mixture is described, etc.

  8. Towards a non-wired simulator for reliability analysis

    International Nuclear Information System (INIS)

    Jurvillier, I.; Laviron, A.; Blin, A.

    1991-11-01

    This paper outlines the objectives and preliminary results of a research programme aiming to increase the advantages of electronic simulators used for reliability studies of complex systems. Research work has resulted in the design of a device based on an electronic simulator capable of carrying out all types of simulation without the drawback of wiring, as is currently the case. Its performance levels as regards speed are comparable to those of wired simulators and this is its main advantage over studies made on a computer. In addition, the simulator is connected to a computer which greatly increases system flexibility and user-friendliness. The first results obtained illustrate what characteristics can be expected of such a system, both as regards the anticipated computation time and the extended processing capabilities (such as the study of common cause failures). (author) [fr

  9. Comparison of the cheese-wiring effects among three sutures used in rotator cuff repair.

    Science.gov (United States)

    Lambrechts, Mark; Nazari, Behrooz; Dini, Arash; O'Brien, Michael J; Heard, Wendell M R; Savoie, Felix H; You, Zongbing

    2014-07-01

    The goal of this study was to compare the cheese-wiring effects of three sutures with different coefficients of friction. Sixteen human cadaveric shoulders were dissected to expose the distal supraspinatus and infraspinatus muscle tendons. Three sutures were stitched through the tendons: #2 Orthocord(™) suture (reference #223114, DePuy Mitek, Inc., Raynham, MA), #2 ETHIBOND* EXCEL Suture, and #2 FiberWire(®) suture (FiberWire(®), Arthrex, Naples, FL). The sutures were pulled by cyclic axial forces from 10 to 70 N at 1 Hz for 1000 cycles through a MTS machine. The cut-through distance on the tendon was measured with a digital caliper. The cut-through distance in the supraspinatus tendons (mean ± standard deviation, n = 12) were 2.9 ± 0.6 mm for #2 Orthocord(™) suture, 3.2 ± 1.2 mm for #2 ETHIBOND* suture, and 4.2 ± 1.7 mm for #2 FiberWire(®) suture. The differences were statistically significant analyzing with analysis of variance (P = 0.047) and two-tailed Student's t-test, which showed significance between Orthocord(™) and FiberWire(®) sutures (P = 0.026), but not significant between Orthocord(™) and ETHIBOND* sutures (P = 0.607) or between ETHIBOND* and FiberWire(®) sutures (P = 0.103). The cheese-wiring effect is less in the Orthocord(™) suture than in the FiberWire(®) suture in human cadaveric supraspinatus tendons. Identification of sutures that cause high levels of tendon cheese-wiring after rotator cuff repair can lead to better suture selection.

  10. All-Cause Mortality up to and After Coronary Heart Disease and Stroke Events in European Middle-Aged Men: The PRIME Study.

    Science.gov (United States)

    Majed, Bilal; Montaye, Michèle; Wagner, Aline; Arveiler, Dominique; Ducimetiere, Pierre; Tafflet, Muriel; Ferrieres, Jean; Ruidavets, Jean-Bernard; Kee, Frank; Evans, Alun; Amouyel, Philippe; Prugger, Christof; Empana, Jean-Philippe

    2015-05-01

    The aim was to investigate prospectively the all-cause mortality risk up to and after coronary heart disease (CHD) and stroke events in European middle-aged men. The study population comprised 10 424 men 50 to 59 years of age recruited between 1991 and 1994 in France (N=7855) and Northern Ireland (N=2747) within the Prospective Epidemiological Study of Myocardial Infarction. Incident CHD and stroke events and deaths from all causes were prospectively registered during the 10-year follow-up. In Cox's proportional hazards regression analysis, CHD and stroke events during follow-up were used as time-dependent covariates. A total of 769 CHD and 132 stroke events were adjudicated, and 569 deaths up to and 66 after CHD or stroke occurred during follow-up. After adjustment for study country and cardiovascular risk factors, the hazard ratios of all-cause mortality were 1.58 (95% confidence interval 1.18-2.12) after CHD and 3.13 (95% confidence interval 1.98-4.92) after stroke. These findings support continuous efforts to promote both primary and secondary prevention of cardiovascular disease. © 2015 American Heart Association, Inc.

  11. Fixation of Trochanteric Fragments in Cementless Bipolar Hemiarthroplasty of Unstable Intertrochanteric Fracture: Cerclage Wiring.

    Science.gov (United States)

    Lee, Young-Kyun; Park, Chan Ho; Koo, Kyung-Hoi

    2017-12-01

    Bipolar hemiarthroplasty (HA) is an option for the treatment of unstable intertrochanteric fracture in elderly patients. There is a raising concern regarding cable-grip related complications for the fixation of trochanteric fragments. Therefore, the aim of this study was to evaluate outcome of cementless HA with fixation for the trochanteric fragments using monofilament wires in unstable intertrochanteric fracture. We reviewed 92 cementless bipolar HAs using a grit-blasted long stem design for unstable intertrochanteric fractures in 91 elderly patients with a mean age of 81.7 years. During the arthroplasty, trochanteric fracture fragments were fixed using 1 or 2 vertical wires and transverse wires. We evaluated the clinical outcomes such as abductor power, ambulatory ability and wire-related complications, and radiologic outcomes including the union of the trochanteric fragment and subsidence of stem. Sixty-two patients were followed for a minimum of 2 years (mean, 59 months) postoperatively. The mean abductor power and Koval category was 4.1 (range, 3 to 5) and 4.6 (range, 1 to 6). The wire was broken in 3 hips (4.8%) and the nonunion of the greater trochanter occurred in 1 hips (1.6%). Two stems subsided by 3 mm and 8 mm, respectively, during postoperative 6 weeks, after which the subsidence was not progressive. Cerclage wiring of the trochanter using monofilament wire leads to acceptable outcome in cementless HA for senile patients with unstable intertrochanteric fracture. Cerclage wiring using a monofilament wire is recommended for the fixation of trochanteric fragments.

  12. Explosion symmetry improvement of polyimide-coated tungsten wire in vacuum on negative discharge facility

    Science.gov (United States)

    Li, Mo; Wu, Jian; Lu, Yihan; Li, Xingwen; Li, Yang; Qiu, Mengtong

    2018-01-01

    Tungsten wire explosion is very asymmetric when fast current rate and insulated coatings are both applied on negative discharge facility using a 24-mm-diameter cathode geometry, which is commonly used on mega-ampere facilities. It is inferred, based on an analytical treatment of the guiding center drift and COMSOL simulations, that the large negative radial electric field causes early voltage breakdown and terminates energy deposition into the wire core on the anode side of the wire. After the anode side is short circuited, the radial electric field along the wire surface on the cathode side will change its polarity and thus leading to additional energy deposition into the wire core. This change causes ˜10 times larger energy deposition and ˜14 times faster explosion velocity in the cathode side than the anode side. In order to reduce this asymmetry, a hollow cylindrical cathode geometry was used to reverse the polarity of radial electric field and was optimized to use on multi-MA facilities. In this case, fully vaporized polyimide-coated tungsten wire with great symmetry improvement was achieved with energy deposition of ˜8.8 eV/atom. The atomic and electronic density distributions for the two different load geometries were obtained by the double-wavelength measurement.

  13. Single wire drift chamber design

    Energy Technology Data Exchange (ETDEWEB)

    Krider, J.

    1987-03-30

    This report summarizes the design and prototype tests of single wire drift chambers to be used in Fermilab test beam lines. The goal is to build simple, reliable detectors which require a minimum of electronics. Spatial resolution should match the 300 ..mu..m rms resolution of the 1 mm proportional chambers that they will replace. The detectors will be used in beams with particle rates up to 20 KHz. Single track efficiency should be at least 99%. The first application will be in the MT beamline, which has been designed for calibration of CDF detectors. A set of four x-y modules will be used to track and measure the momentum of beam particles.

  14. Assessing the repeatability of verbal autopsy for determining cause of death: two case studies among women of reproductive age in Burkina Faso and Indonesia

    Directory of Open Access Journals (Sweden)

    Ouédraogo Moctar

    2009-05-01

    Full Text Available Abstract Background Verbal autopsy (VA is an established tool for assessing cause-specific mortality patterns in communities where deaths are not routinely medically certified, and is an important source of data on deaths among the poorer half of the world's population. However, the repeatability of the VA process has never been investigated, even though it is an important factor in its overall validity. This study analyses repeatability in terms of the overall VA process (from interview to cause-specific mortality fractions (CSMF, as well as specifically for interview material and individual causes of death, using data from Burkina Faso and Indonesia. Methods Two series of repeated VA interviews relating to women of reproductive age in Burkina Faso (n = 91 and Indonesia (n = 116 were analysed for repeatability in terms of interview material, individual causes of death and CSMFs. All the VA data were interpreted using the InterVA-M model, which provides 100% intrinsic repeatability for interpretation, and thus eliminated the need to consider variations or repeatability in physician coding. Results The repeatability of the overall VA process from interview to CSMFs was good in both countries. Repeatability was moderate in the interview material, and lower in terms of individual causes of death. Burkinabé data were less repeatable than Indonesian, and repeatability also declined with longer recall periods between the death and interview, particularly after two years. Conclusion While these analyses do not address the validity of the VA process in absolute terms, repeatability is a prerequisite for intrinsic validity. This study thus adds new understanding to the quest for reliable cause of death assessment in communities lacking routine medical certification of deaths, and confirms the status of VA as an important and reliable tool at the community level, but perhaps less so at the individual level.

  15. Development of CRID [Cerenkov Ring Imaging Detector] single electron wire detector

    International Nuclear Information System (INIS)

    Aston, D.; Bean, A.; Bienz, T.

    1989-02-01

    We describe the R and D effort to define the design parameters, method of construction and experimental results from the single electron wire detectors. These detectors will be used for particle identification using the Cerenkov Ring Imaging techniques in the SLD experiment at SLAC. We present measurements of pulse heights for several gases as a function of gas gain, charge division performance on a single electron signal using both 7 μm and 33 μm diameter carbon wires, photon feedback in TMAE laden gas, average pulse shape, and its comparison with the predicted shape and cross-talk. In addition, we present results of wire aging tests, and other tests associated with construction of this unusual type of wire chamber. 12 refs., 9 figs

  16. Polymer growth rate in a wire chamber with oxygen, water, or alcohol gas additives

    International Nuclear Information System (INIS)

    Boyarski, Adam M.

    2009-01-01

    The rate of polymer growth on wires was measured in a wire chamber while the chamber was aged initially with helium:isobutane (80:20) gas, and then with either oxygen, water, or alcohol added to the gas. At the completion of the aging process for each gas mixture, the carbon content on the wires was measured in a scanning electron microscope/energy dispersive X-ray (SEM/EDX) instrument. The same physical wires were used in all the gas mixtures, allowing measurement of polymer build-up or polymer depletion by each gas additive. It is found that the rate of polymer growth is not changed by the presence of oxygen, water, or alcohol. Conjecture that oxygen reduces breakdown by removing polymer deposits on field wires is negated by these measurements. Instead, it appears that the reduced breakdown is due to lower resistance in the polymer from oxygen ions being transported into the polymer. It is also observed that field wires bombarded by the electrons in the SEM and then placed back into the chamber show an abundance of single electrons being emitted, indicating that electron charge is trapped in the polymer layer and that a high electric field is necessary to remove the charge.

  17. Occupational groups and main causes of hospitalization: a longitudinal multicohort study of the Finnish working-age population, 1976 to 2010.

    Science.gov (United States)

    Varje, Pekka; Kokkinen, Lauri; Kouvonen, Anne; Koskinen, Aki; Väänänen, Ari

    2014-08-01

    To determine whether transitions in the hospitalization structure of different occupational groups have followed similar trends. Secular trends for all-cause hospitalization and five main diagnostic categories among six occupational groups were examined between 1976 and 2010 in Finland. The register-based study consisted of a 5-year follow-up of 1,126,499 Finnish working-aged residents in seven consecutive cohorts. Altogether 451,737 hospitalizations were investigated in 1976 to 2010. The risks of all-cause hospitalization, mental disorders, and respiratory illnesses remained relatively stable, whereas that of musculoskeletal disorders increased (between 31% and 90%) and that of cardiovascular diseases decreased (between 41% and 62%) in all occupational groups. The highest variation was found for cancer. A common health transition pattern seems to have occurred in the occupational groups studied. Nevertheless, the health disparities between the groups were sustained.

  18. Early stages of Alzheimer's disease are alarming signs in injury deaths caused by traffic accidents in elderly people (≥60 years of age): A neuropathological study.

    Science.gov (United States)

    Wijesinghe, Printha; Gorrie, Catherine; Shankar, S K; Chickabasaviah, Yasha T; Amaratunga, Dhammika; Hulathduwa, Sanjayah; Kumara, K Sunil; Samarasinghe, Kamani; Suh, Yoo-Hun; Steinbusch, H W M; De Silva, K Ranil D

    2017-01-01

    There is little information available in the literature concerning the contribution of dementia in injury deaths in elderly people (≥60 years). This study was intended to investigate the extent of dementia-related pathologies in the brains of elderly people who died in traffic accidents or by suicide and to compare our findings with age- and sex-matched natural deaths in an elderly population. Autopsy-derived human brain samples from nine injury death victims (5 suicide and 4 traffic accidents) and nine age- and sex-matched natural death victims were screened for neurodegenerative and cerebrovascular pathologies using histopathological and immunohistochemical techniques. For the analysis, Statistical Package for the Social Sciences (SPSS) version 16.0 was used. There was a greater likelihood for Alzheimer's disease (AD)-related changes in the elders who succumbed to traffic accidents (1 out of 4) compared to age- and sex-matched suicides (0 out of 5) or natural deaths (0 out of 9) as assessed by the National Institute on Aging - Alzheimer's Association guidelines. Actual burden of both neurofibrillary tangles (NFTs) and (SPs) was comparatively higher in the brains of traffic accidents, and the mean NFT counts were significantly higher in the region of entorhinal cortex ( P stages may be a contributing factor to injury deaths caused by traffic accidents in elderly people whereas suicidal brain neuropathologies resembled natural deaths.

  19. Minimum quench energy measurement for superconducting wires

    International Nuclear Information System (INIS)

    Seo, K.; Morita, M.; Nakamura, S.; Yamada, T.; Jizo, Y.

    1996-01-01

    The authors have developed a new method of measuring minimum quench energy (MQE) of superconducting wire. There have been conventional methods using heating wires, whose diameters are ∼0.1mm and are glued by epoxy resin. When they induce a pulse heat to superconducting wires, a duration of the pulse must be several hundreds micro seconds to demonstrate actual disturbances (for instance wire motion) in a superconducting magnet. In spite of this fact, thermal diffusion time constants of the conventional heaters are larger than the duration of the actual disturbance, because of these electrical insulator of the heating wire and the epoxy bind. Therefore, this kind of heater is not able to demonstrate the actual disturbance. To solve this problem, they have proposed a new constitution of a heater. In the method, heat generation is introduced in high resistive layer on a surface of a superconducting wire. The high resistive layer is consist of carbon paste. The thickness of the carbon paste layer is ∼20microm, thus a time constant of this heater is expected to be small enough to demonstrate the actual disturbance. Adopting the new method to the MQE measurement, they successfully evaluate MQE of superconducting wires with high precision. Several results are introduced in this paper

  20. Wire pad chamber for LHCb muon system

    CERN Document Server

    Botchine, B; Lazarev, V A; Sagidova, N; Vorobev, A P; Vorobyov, A; Vorobyov, Alexei

    2000-01-01

    2000-003 Wire pad chambers (WPC) have been proposed for the outer Region 4 of the LHCb Muon System. These are double gap MWPCs with small wire spacing allowing to obtain 99% detection efficiency in a 20 ns time window. The chambers have a rectangular shape with the vertical dimension from 20 cm in Station 1 to 30 cm in Station 5. The horizontal dimensions will be different with the maximal size of 3 meters in Station 5. The wires are in the vertical direction. The short wire length allows to use small wire spacing needed for high time resolution. Also, this helps to obtain the uniform gas gain over the whole chamber area. The WPC has one row of the wire pads formed by grouping wires in separate readout channels. Four WPC prototypes have been built at PNPI and tested in the PS beam at CERN. Here we report on the results from these tests. Also, the results of simulation of the WPC performance are presented.

  1. Resonant tunneling of electrons in quantum wires

    International Nuclear Information System (INIS)

    Krive, I.V.; Shekhter, R.I.; Jonson, M.; Krive, I.V.

    2010-01-01

    We considered resonant electron tunneling in various nanostructures including single wall carbon nanotubes, molecular transistors and quantum wires formed in two-dimensional electron gas. The review starts with a textbook description of resonant tunneling of noninteracting electrons through a double-barrier structure. The effects of electron-electron interaction in sequential and resonant electron tunneling are studied by using Luttinger liquid model of electron transport in quantum wires. The experimental aspects of the problem (fabrication of quantum wires and transport measurements) are also considered. The influence of vibrational and electromechanical effects on resonant electron tunneling in molecular transistors is discussed.

  2. Rodent Zic Genes in Neural Network Wiring.

    Science.gov (United States)

    Herrera, Eloísa

    2018-01-01

    The formation of the nervous system is a multistep process that yields a mature brain. Failure in any of the steps of this process may cause brain malfunction. In the early stages of embryonic development, neural progenitors quickly proliferate and then, at a specific moment, differentiate into neurons or glia. Once they become postmitotic neurons, they migrate to their final destinations and begin to extend their axons to connect with other neurons, sometimes located in quite distant regions, to establish different neural circuits. During the last decade, it has become evident that Zic genes, in addition to playing important roles in early development (e.g., gastrulation and neural tube closure), are involved in different processes of late brain development, such as neuronal migration, axon guidance, and refinement of axon terminals. ZIC proteins are therefore essential for the proper wiring and connectivity of the brain. In this chapter, we review our current knowledge of the role of Zic genes in the late stages of neural circuit formation.

  3. Outcomes of dynamic hip screw augmented with trochanteric wiring for treatment of unstable type A2 intertrochanteric femur fractures.

    Science.gov (United States)

    Puram, Chetan; Pradhan, Chetan; Patil, Atul; Sodhai, Vivek; Sancheti, Parag; Shyam, Ashok

    2017-08-01

    Posteromedial and greater trochanteric fragments are a major cause of telescoping and medialization of the femoral shaft in an unstable intertrochanteric fracture. This leads to significant limb shortening, fracture collapse in varus position and implant failure, which can be prevented by trochanteric wiring in addition to dynamic hip screw (DHS) fixation. The purpose of our study is to assess the outcomes of DHS augmented with trochanteric wiring in unstable type A2 intertrochanteric fractures. One hundred and two retrospective cases of unstable intertrochanteric fractures treated with DHS between January 2010 and December 2015 with a minimum follow-up period of 12 months were reviewed. Out of 102 cases, 28 were treated with DHS and derotation screw alone (Group A), while in rest 74 cases trochanteric wiring was used as an augmentation to DHS and derotation screw (Group B). Patients were evaluated clinically for range of motion, Harris hip score and Oxford hip score. Radiologically, fracture reduction, change in neck shaft angle and neck length ratio in comparison to opposite hip and union status of greater trochanter were assessed. The mean age of the patients at the time of surgery was 72 years (range 23-94 years) with 48 males and 54 females. The mean follow-up period was 20 months (range 12-48 months). The Harris hip score, Oxford hip score, shortening, attainment of weight bearing and change in neck shaft angle was not significantly different between the two groups (all p values >0.05). Incidence of greater trochanter nonunion was greater in group A (17.85%) as compared to group B (6.75%). We found significant association between occurrence of limp with varus change in neck shaft angle, decrease in neck length ratio and greater trochanteric non-union (all p values wiring in unstable intertrochanteric fractures gives similar result to group without no wiring, although greater trochanter non-union rate was more in the latter group. Limp can be prevented by

  4. Survival and cause of death after transcatheter aortic valve replacement as compared to an age- and sex-matched background population

    DEFF Research Database (Denmark)

    Theut, Marie; Thygesen, Julie B; De Backer, Ole

    2017-01-01

    AIMS: This study aimed to assess survival and causes of death in a real-world TAVR population as compared to an age- and sex-matched background population. METHODS AND RESULTS: Each aortic stenosis (AS) patient treated with TAVR in Eastern Denmark between 2007 and 2014 (n=617) was matched with 25...... age- and sex-matched controls (n=15,425) randomly drawn from the general Danish population. In the total TAVR population, early mortality (≤90 days) was significantly higher (hazard ratio [HR] 3.90 [2.82-5.39]; ppopulation, driven mainly by cardiovascular (CV......) mortality. Late mortality (>90 days) was not different between the TAVR and background population (HR 1.16 [0.96-1.40]; p=0.126), causes of death being mainly non-CV. In subgroup analysis, the HR for late mortality was 0.98, 1.11, and 1.90 for the low-, intermediate-, and high-risk TAVR groups, respectively...

  5. Metabolic syndrome, major depression, generalized anxiety disorder, and ten-year all-cause and cardiovascular mortality in middle aged and elderly patients.

    Science.gov (United States)

    Butnoriene, Jurate; Bunevicius, Adomas; Saudargiene, Ausra; Nemeroff, Charles B; Norkus, Antanas; Ciceniene, Vile; Bunevicius, Robertas

    2015-01-01

    Studies investigating specifically whether metabolic syndrome (MetS) and common psychiatric disorders are independently associated with mortality are lacking. In a middle-aged general population, we investigated the association of the MetS, current major depressive episode (MDE), lifetime MDE, and generalized anxiety disorder (GAD) with ten-year all-cause and cardiovascular disease mortality. From February 2003 until January 2004, 1115 individuals aged 45 years and older were randomly selected from a primary care practice and prospectively evaluated for: (1) MetS (The World Health Organization [WHO], National Cholesterol Education Program/Adult Treatment Panel III and International Diabetes Federation [IDF] definitions); (2) current MDE and GAD, and lifetime MDE (Mini International Neuropsychiatric Interview); and (3) conventional cardiovascular risk factors. Follow-up continued through January, 2013. During the 9.32 ± 0.47 years of follow-up, there were 248 deaths, of which 148 deaths were attributed to cardiovascular causes. In women, WHO-MetS and IDF-MetS were associated with greater all-cause (HR-values range from 1.77 to 1.91; p-values ≤ 0.012) and cardiovascular (HR-values range from 1.83 to 2.77; p-values ≤ 0.013) mortality independent of cardiovascular risk factors and MDE/GAD. Current GAD predicted greater cardiovascular mortality (HR-values range from 1.86 to 1.99; p-values ≤ 0.025) independently from MetS and cardiovascular risk factors. In men, the MetS and MDE/GAD were not associated with mortality. In middle aged women, the MetS and GAD predicted greater 10-year cardiovascular mortality independently from each other; 10-year all-cause mortality was independently predicted by the MetS. MetS and GAD should be considered important and independent mortality risk factors in women. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. 5-aminolevulinic acid (ALA) deficiency causes impaired glucose tolerance and insulin resistance coincident with an attenuation of mitochondrial function in aged mice.

    Science.gov (United States)

    Saitoh, Shinichi; Okano, Satoshi; Nohara, Hidekazu; Nakano, Hiroshi; Shirasawa, Nobuyuki; Naito, Akira; Yamamoto, Masayuki; Kelly, Vincent P; Takahashi, Kiwamu; Tanaka, Tohru; Nakajima, Motowo; Nakajima, Osamu

    2018-01-01

    In vertebrates, the initial step in heme biosynthesis is the production of 5-aminolevulinic acid (ALA) by ALA synthase (ALAS). ALA formation is believed to be the rate-limiting step for cellular heme production. Recently, several cohort studies have demonstrated the potential of ALA as a treatment for individuals with prediabetes and type-2 diabetes mellitus. These studies imply that a mechanism exists by which ALA or heme can control glucose metabolism. The ALAS1 gene encodes a ubiquitously expressed isozyme. Mice heterozygous null for ALAS1 (A1+/-s) experience impaired glucose tolerance (IGT) and insulin resistance (IR) beyond 20-weeks of age (aged A1+/-s). IGT and IR were remedied in aged A1+/-s by the oral administration of ALA for 1 week. However, the positive effect of ALA proved to be reversible and was lost upon termination of ALA administration. In the skeletal muscle of aged A1+/-s an attenuation of mitochondrial function is observed, coinciding with IGT and IR. Oral administration of ALA for 1-week brought about only a partial improvement in mitochondrial activity however, a 6-week period of ALA treatment was sufficient to remedy mitochondrial function. Studies on differentiated C2C12 myocytes indicate that the impairment of glucose metabolism is a cell autonomous effect and that ALA deficiency ultimately leads to heme depletion. This sequela is evidenced by a reduction of glucose uptake in C2C12 cells following the knockdown of ALAS1 or the inhibition of heme biosynthesis by succinylacetone. Our data provide in vivo proof that ALA deficiency attenuates mitochondrial function, and causes IGT and IR in an age-dependent manner. The data reveals an unexpected metabolic link between heme and glucose that is relevant to the pathogenesis of IGT/IR.

  7. Development of medical guide wire of Cu-Al-Mn-base superelastic alloy with functionally graded characteristics.

    Science.gov (United States)

    Sutou, Yuji; Omori, Toshihiro; Furukawa, Akihisa; Takahashi, Yukinori; Kainuma, Ryosuke; Yamauchi, Kiyoshi; Yamashita, Shuzo; Ishida, Kiyohito

    2004-04-15

    A new type of medical guide wire with functionally graded hardness from the tip to the end was developed with the use of Cu-Al-Mn-based alloys. The superelasticity (SE) of the Cu-Al-Mn-based alloys in the tip is drastically improved by controlling the grain size, whereas the end of the wire is hardened using bainitic transformation by aging at around 200-400 degrees C. Therefore, the tip of the guide wire shows a superelasticity and its end has high stiffness. This guide wire with functionally graded characteristics shows excellent pushability and torquability, superior to that of the Ni-Ti guide wire. Copyright 2004 Wiley Periodicals, Inc.

  8. A prospective study of bone lead concentration and death from all causes, cardiovascular diseases, and cancer in the VA Normative Aging Study

    Science.gov (United States)

    Weisskopf, Marc G.; Jain, Nitin; Nie, Huiling; Sparrow, David; Vokonas, Pantel; Schwartz, Joel; Hu, Howard

    2009-01-01

    Background Blood lead concentration has been associated with mortality from different causes in several studies. Many effects of lead exposure that might increase risk of death are likely to result from cumulative exposure, for which bone lead is a better biomarker than blood lead. The association between bone lead levels and mortality has not been explored. Methods and Results We prospectively assessed the association between both blood lead and bone lead—analyzed using K-x-ray fluorescence—and mortality among 868 men in the Normative Aging Study. We identified 241 deaths over an average of 8.9 (sd=3.9) years of follow-up. We calculated adjusted hazard ratios (HR) and 95% confidence intervals (CI) using Cox proportional hazards. Compared to the lowest tertile of patella bone lead, the fully adjusted HR in the highest tertile for all cause and cardiovascular mortality (n=137 deaths) were 2.52 (95% CI: 1.17–5.41) and 5.63 (95% CI: 1.73–18.3), respectively. The age, smoking, and race-adjusted HR for ischemic heart disease mortality (n=62 deaths) in the highest tertile was 8.37 (95% CI: 1.29–54.4). Results were similar for tibia lead. Bone lead was not associated with cancer, and blood lead was not associated with any mortality category. Conclusions We found bone lead to be associated with all-cause and cardiovascular mortality in an environmentally-exposed population with low blood lead levels. This study suggests that cumulative lead exposure from prior decades of high environmental exposures continues to significantly impact risk of death despite recent declines in environmental lead exposure. PMID:19738141

  9. Prevalence of papular urticaria caused by flea bites and associated factors in children 1–6 years of age in Bogotá, D.C.

    Directory of Open Access Journals (Sweden)

    Evelyne Halpert

    2017-11-01

    Full Text Available Abstract Background Papular urticaria is a chronic inflammatory disease caused by exposure to arthropod bites. The disease has been reported in children attending medical centers, but the causes as the risk factors associated with the disease have not been established. The objective of this study was to determine the prevalence of papular urticaria caused by flea bite and identify the risk factors in children between 1 to 6 years of age in Bogotá D.C, between March 2009 and June 2011. Methods A cross-sectional, two-stage, clustered study using random probability sampling and stratified with proportional allocation was carried out in children (1–6 years of age in educational institutions in Bogotá D.C. to determine the prevalence of the disease. Children underwent a dermatological examination by general practitioners with a previous training. Furthermore, digital photographs of skin lesions were taken for further confirmation of the diagnosis by dermatologists. A structured survey was completed by the parents or caregivers, and it was evaluated using an unconditional logistic regression to identify factors associated with the disease. Results A total of 2437 children were included in the study. The prevalence of papular urticaria caused by flea bite in this population was 20.3% (CI 95%: 18.2 to 22.5%. The major risk factors associated with the disease were the presence of fleas in households (OR 1.74, CI 95%: 1.35 to 2.25, using mattresses without springs (OR 1.73, CI 95%: 1.20 to 2.50, the use of daily public transportation to carry the children to the educational institutions (OR 1.76, CI 95%: 1.07 to 2.89, having a soil/earth floor in the main bedroom (OR 6.81, CI 95%:1.16–39.96, and having siblings with a history of atopic dermatitis (OR 1.76 CI 95%: 1.07–2.89. Conclusions A high prevalence of papular urticaria caused by flea bite was found in Bogotá D.C. The main factors associated with the disease might be modified with the

  10. Experience with FiberWire for pectus bar attachment.

    Science.gov (United States)

    McMahon, L E; Johnson, K N; Jaroszewski, D E; Acosta, J M; Egan, J C; Bae, J; Ngyuen, H; Notrica, D M

    2014-08-01

    Minimally invasive repair of pectus excavatum has become an established method for repair of pectus excavatum. Bar displacement or rotation remains the most common complication of this repair requiring return to the operating room. Retrospective review of all patients at a single institution who underwent repair of pectus excavatum using FiberWire for bar stabilization between December 2009 and March 2013 was undertaken. 93 patients underwent minimally invasive pectus repair using FiberWire during the study period. The patients included 73 males and 20 females, with an average age of 14.6years (range 7-21years). Mean operative time was 102minutes (range 56-198minutes). No patients developed wound complications, two patients developed pain because of bar migration and required return to the OR, and no patients had recurrence of their pectus defect because of bar migration during the study period. Median length of follow-up was 17months (range 3-36months). Stabilization of pectus bars using circumferential rib fixation with FiberWire at multiple points on both sides of the bar appears to be effective in preventing bar rotation and displacement, and requires minimal change to the operation as it has been previously described. Early experience shows a low rate of complications. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Low Systolic Blood Pressure and Mortality From All Causes and Vascular Diseases Among Older Middle-aged Men: Korean Veterans Health Study

    Directory of Open Access Journals (Sweden)

    Sang-Wook Yi

    2015-03-01

    Full Text Available Objectives: Recently, low systolic blood pressure (SBP was found to be associated with an increased risk of death from vascular diseases in a rural elderly population in Korea. However, evidence on the association between low SBP and vascular diseases is scarce. The aim of this study was to prospectively examine the association between low SBP and mortality from all causes and vascular diseases in older middle-aged Korean men. Methods: From 2004 to 2010, 94 085 Korean Vietnam War veterans were followed-up for deaths. The adjusted hazard ratios (aHR were calculated using the Cox proportional hazard model. A stratified analysis was conducted by age at enrollment. SBP was self-reported by a postal survey in 2004. Results: Among the participants aged 60 and older, the lowest SBP (<90 mmHg category had an elevated aHR for mortality from all causes (aHR, 1.9; 95% confidence interval [CI], 1.2 to 3.1 and vascular diseases (International Classification of Disease, 10th revision, I00-I99; aHR, 3.2; 95% CI, 1.2 to 8.4 compared to those with an SBP of 100 to 119 mmHg. Those with an SBP below 80 mmHg (aHR, 4.5; 95% CI, 1.1 to 18.8 and those with an SBP of 80 to 89 mmHg (aHR, 3.1; 95% CI, 0.9 to 10.2 also had an increased risk of vascular mortality, compared to those with an SBP of 90 to 119 mmHg. This association was sustained when excluding the first two years of follow-up or preexisting vascular diseases. In men younger than 60 years, the association of low SBP was weaker than that in those aged 60 years or older. Conclusions: Our findings suggest that low SBP (<90 mmHg may increase vascular mortality in Korean men aged 60 years or older.

  12. Microstructure, mechanical behaviour and fracture of pure tungsten wire after different heat treatments

    DEFF Research Database (Denmark)

    Zhao, P.; Riesch, J.; Höschen, T.

    2017-01-01

    treatments in terms of microstructure, mechanical behaviour and fracture mode. Recrystallization is already observed at a relatively low temperature of 1273 K due to the large driving force caused by a high dislocation density. Annealing for 30 min at 1900 K also leads to recrystallization, but causes......-edge-necking of individual grains on the fracture surface. While the wire recrystallized at 1900 K displays large, almost equiaxed grains with low aspect ratios as well as distinct brittle properties. Therefore, it is suggested that a high aspect ratio of the grains is important for the ductile behaviour of tungsten wire...

  13. Ageing as a price of cooperation and complexity: self-organization of complex systems causes the gradual deterioration of constituent networks.

    Science.gov (United States)

    Kiss, Huba J M; Mihalik, Agoston; Nánási, Tibor; Ory, Bálint; Spiró, Zoltán; Soti, Csaba; Csermely, Peter

    2009-06-01

    The network concept is increasingly used for the description of complex systems. Here, we summarize key aspects of the evolvability and robustness of the hierarchical network set of macromolecules, cells, organisms and ecosystems. Listing the costs and benefits of cooperation as a necessary behaviour to build this network hierarchy, we outline the major hypothesis of the paper: the emergence of hierarchical complexity needs cooperation leading to the ageing (i.e. gradual deterioration) of the constituent networks. A stable environment develops cooperation leading to over-optimization, and forming an 'always-old' network, which accumulates damage, and dies in an apoptosis-like process. A rapidly changing environment develops competition forming a 'forever-young' network, which may suffer an occasional over-perturbation exhausting system resources, and causing death in a necrosis-like process. Giving a number of examples we demonstrate how cooperation evokes the gradual accumulation of damage typical to ageing. Finally, we show how various forms of cooperation and consequent ageing emerge as key elements in all major steps of evolution from the formation of protocells to the establishment of the globalized, modern human society.

  14. 47 CFR 76.802 - Disposition of cable home wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Disposition of cable home wiring. 76.802... MULTICHANNEL VIDEO AND CABLE TELEVISION SERVICE Cable Inside Wiring § 76.802 Disposition of cable home wiring... cable operator shall not remove the cable home wiring unless it gives the subscriber the opportunity to...

  15. Automatic reel controls filler wire in welding machines

    Science.gov (United States)

    Millett, A. V.

    1966-01-01

    Automatic reel on automatic welding equipment takes up slack in the reel-fed filler wire when welding operation is terminated. The reel maintains constant, adjustable tension on the wire during the welding operation and rewinds the wire from the wire feed unit when the welding is completed.

  16. 47 CFR 32.2321 - Customer premises wiring.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 2 2010-10-01 2010-10-01 false Customer premises wiring. 32.2321 Section 32... Customer premises wiring. (a) This account shall include all amounts transferred from the former Account 232, Station Connections, inside wiring subclass. (b) Embedded Customer Premises Wiring is that...

  17. 30 CFR 77.701-3 - Grounding wires; capacity.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Grounding wires; capacity. 77.701-3 Section 77... MINES Grounding § 77.701-3 Grounding wires; capacity. Where grounding wires are used to ground metallic sheaths, armors, conduits, frames, casings, and other metallic enclosures, such grounding wires will be...

  18. Structure and Properties of Coatings Made with Self Shielded Cored Wire

    Directory of Open Access Journals (Sweden)

    Gucwa M.

    2016-09-01

    Full Text Available The welding technologies are widely used for design of protection layer against wear and corrosion. Hardfacing, which is destined for obtaining coatings with high hardness, takes special place in these technologies. One of the most effective way of hardfacing is using self shielded flux cored arc welding (FCAW-S. Chemical composition obtained in flux cored wire is much more rich in comparison to this obtained in solid wire. The filling in flux cored wires can be enriched for example with the mixture of hard particles or phases with specified ratio, which is not possible for solid wires. This is the reason why flux cored wires give various possibilities of application of this kind of filler material for improving surface in mining industry, processing of minerals, energetic etc. In the present paper the high chromium and niobium flux cored wire was used for hardfacing process with similar heat input. The work presents studies of microstructures of obtained coatings and hardness and geometric properties of them. The structural studies were made with using optical microscopy and X-ray diffraction that allowed for identification of carbides and other phases obtained in the structures of deposited materials. Investigated samples exhibit differences in coating structures made with the same heat input 4,08 kJ/mm. There are differences in size, shape and distribution of primary and eutectic carbides in structure. These differences cause significant changes in hardness of investigated coatings.

  19. Wire Bonder: Kulicke and Soffa Model 4526

    Data.gov (United States)

    Federal Laboratory Consortium — Description:CORAL Name: Wire BonderNeeds Description.Scientific Opportunities / Applications:Wedge bonderSemi-automatic and manual modesIndependent Z-axis control,...

  20. Beam Profiling through Wire Chambing Tracking

    CERN Document Server

    Nash, W

    2013-01-01

    This note describes the calibration of the Delay Wire Chambers (DWCs) used during test runs of CALICE’s Tungsten Digital Hadron Calorimeter (W-DHCAL) prototype in CERN’s SPS beam line (10 – 300 GeV).

  1. Copyright and Wire Broadcasting Under Belgian Law

    Science.gov (United States)

    Namurois, Albert

    1975-01-01

    A discussion of a case whereby substantial damages, if not criminal proceedings, will sanction, according to circumstances, both television organizations and those who in certain conditions distribute their programs by wire or communicate them to the public. (Author/HB)

  2. Josephson junction arrays and superconducting wire networks

    International Nuclear Information System (INIS)

    Lobb, C.J.

    1992-01-01

    Techniques used to fabricate integrated circuits make it possible to construct superconducting networks containing as many as 10 6 wires or Josephson junctions. Such networks undergo phase transitions from resistive high-temperature states to ordered low-resistance low-temperature states. The nature of the phase transition depends strongly on controllable parameters such as the strength of the superconductivity in each wire or junction and the external magnetic field. This paper will review the physics of these phase transitions, starting with the simplest zero-magnetic field case. This leads to a Kosterlitz-Thouless transition when the junctions or wires are weak, and a simple mean-field fransition when the junctions or wires are strong. Rich behavior, resulting from frustration, occurs in the presence of a magnetic field. (orig.)

  3. Highly stretchable wrinkled gold thin film wires.

    Science.gov (United States)

    Kim, Joshua; Park, Sun-Jun; Nguyen, Thao; Chu, Michael; Pegan, Jonathan D; Khine, Michelle

    2016-02-08

    With the growing prominence of wearable electronic technology, there is a need to improve the mechanical reliability of electronics for more demanding applications. Conductive wires represent a vital component present in all electronics. Unlike traditional planar and rigid electronics, these new wearable electrical components must conform to curvilinear surfaces, stretch with the body, and remain unobtrusive and low profile. In this paper, the piezoresistive response of shrink induced wrinkled gold thin films under strain demonstrates robust conductive performance in excess of 200% strain. Importantly, the wrinkled metallic thin films displayed negligible change in resistance of up to 100% strain. The wrinkled metallic wires exhibited consistent performance after repetitive strain. Importantly, these wrinkled thin films are inexpensive to fabricate and are compatible with roll to roll manufacturing processes. We propose that these wrinkled metal thin film wires are an attractive alternative to conventional wires for wearable applications.

  4. Tensosensitivity of the Hot-Wire Probe

    National Research Council Canada - National Science Library

    Pak, A

    2002-01-01

    ...., on the anemometer type. In a constant current anemometer, it is possible to measure and separate out the noise moving to the electric circuit of the anemometer, it is not the case with hot-wire anemometers of other types...

  5. Molecular wires, switches and memories

    Science.gov (United States)

    Chen, Jia

    Molecular electronics, an emerging field, makes it possible to build individual molecules capable of performing functions identical or analogous to present- day conductors, switches, or memories. These individual molecules, with a nano-meter scale characteristic length, can be designed and chemically synthesized with specific atoms, geometries and charge distribution. This thesis focuses on the design, and measurements of molecular wires, and related strategically engineered structures-molecular switches and memories. The experimental system relies on a thermodynamically driven self-assembling process to attach molecules onto substrate surfaces without intervention from outside. The following topics will be discussed: directed nanoscale manipulation of self-assembled molecules using scanning tunneling microscope; investigation on through-bond transport of nanoscale symmetric metal/conjugated self- assembled monolayers (SAM)/metal junctions, where non- Ohmic thermionic emission was observed to be the dominant process, with isocyanide-Pd contacts showing the lowest thermionic barrier of 0.22 eV; the first realization of robust and large reversible switching behavior in an electronic device that utilizes molecules containing redox centers as the active component, exhibiting negative differential resistance (NDR) and large on-off peak-to-valley ratio (PVR); observation of erasable storage of higher conductivity states in these redox- center containing molecular devices, and demonstration of a two-terminal electronically programmable and erasable molecular memory cell with long bit retention time.

  6. Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires.

    Science.gov (United States)

    Tada, Yoshifumi; Hayakawa, Tohru; Nakamura, Yoshiki

    2017-08-09

    Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 × 0.022 in² and 0.019 × 0.025 in² (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bending properties were evaluated in a modified three-point bending system for orthodontics. The static friction between the orthodontic wire and the bracket was also measured. The load-deflection curves were similar among Ni-Ti and PEEK wires, except for 16PEEK with slot-lid ligation. The bending force of 19-25PEEK wire was comparable with that of Ni-Ti wire. 19-25PEEK showed the highest load at the deflection of 1500 μm ( p 0.05). No significant difference was seen in static friction between all three PEEK wires and Ni-Ti wire ( p > 0.05). It is suggested that 19-25PEEK will be applicable for orthodontic treatment with the use of slot-lid ligation.

  7. Audio wiring guide how to wire the most popular audio and video connectors

    CERN Document Server

    Hechtman, John

    2012-01-01

    Whether you're a pro or an amateur, a musician or into multimedia, you can't afford to guess about audio wiring. The Audio Wiring Guide is a comprehensive, easy-to-use guide that explains exactly what you need to know. No matter the size of your wiring project or installation, this handy tool provides you with the essential information you need and the techniques to use it. Using The Audio Wiring Guide is like having an expert at your side. By following the clear, step-by-step directions, you can do professional-level work at a fraction of the cost.

  8. Differences in the Microbial Colonization Among Arch Wire Types, Gauges and Cross Sections

    Directory of Open Access Journals (Sweden)

    Reem A. Rafeeq

    2018-02-01

    Full Text Available Background: The presence of orthodontic materials in the oral cavity represent a unique surface that can interact with bacteria, leading to pathogenic plaque formation and subsequent enamel demineralization, Streptococcus mutans play an important role in the initiation and progression of dental caries and they are considered the primary cause of bacteriological caries. The objective of this study was to investigate the effect of multiple factors including the type of arch wire, salivary coating, cross section, and wire thickness on the levels of mutans streptococci adherence. Materials and Methods: Two types of arch wire stainless steel and nickel titanium were selected using the following criteria: round and rectangular with gauges 0.014, 0.018, 0.016 × 0.022 and 0.019 × 0.0 25 inches which were subdivided into eight groups. Bacterial adhesion was quantified by a microbial culture technique and the number of adhesive bacteria were analyzed and counted after growth in culture for each group with and without saliva coating at 15 and 60 minutes. Detection of mutans streptococci by saliva-check Mutans test. Results: There was a significant difference between arch wire types in each time interval and the highest bacterial adhesion on the NiTi arch wires with rectangular cross section in the absence of saliva with extended incubation time. Conclusions: The adherence of mutans streptococci in saliva coated wires seems to be low. At increased incubation time, rectangular cross section arch wire showed an increased number of adhering bacteria with less effect on different gauges of the arch wire.

  9. Effect Of Low External Flow On Flame Spreading Over ETFE Insulated Wire Under Microgravity

    Science.gov (United States)

    Nishizawa, Katsuhiro; Fujita, Osamu; Ito, Kenichi; Kikuchi, Masao; Olson, Sandra L.; Kashiwagi, Takashi

    2003-01-01

    Fire safety is one of the most important issues for manned space missions. A likely cause of fires in spacecraft is wire insulation combustion in electrical system. Regarding the wire insulation combustion it important to know the effect of low external flow on the combustion because of the presence of ventilation flow in spacecraft. Although, there are many researches on flame spreading over solid material at low external flows under microgravity, research dealing with wire insulation is very limited. An example of wire insulation combustion in microgravity is the Space Shuttle experiments carried out by Greenberg et al. However, the number of experiments was very limited. Therefore, the effect of low flow velocity is still not clear. The authors have reported results on flame spreading over ETFE (ethylene - tetrafluoroetylene) insulated wire in a quiescent atmosphere in microgravity by 10 seconds drop tower. The authors also performed experiments of polyethylene insulated nichrom wire combustion in low flow velocity under microgravity. The results suggested that flame spread rate had maximum value in low flow velocity condition. Another interesting issue is the effect of dilution gas, especially CO2, which is used for fire extinguisher in ISS. There are some researches working on dilution gas effect on flame spreading over solid material in quiescent atmosphere in microgravity. However the research with low external flow is limited and, of course, the research discussing a relation of the appearance of maximum wire flammability in low flow velocity region with different dilution gas cannot be found yet. The present paper, therefore, investigates the effect of opposed flow with different dilution gas on flame spreading over ETFE insulated wire and change in the presence of the maximum flammability depending on the dilution gas type is discussed within the limit of microgravity time given by ground-based facility.

  10. Lifestyle Changes in Young Adulthood and Middle Age and Risk of Cardiovascular Disease and All-Cause Mortality: The Doetinchem Cohort Study.

    Science.gov (United States)

    Hulsegge, Gerben; Looman, Moniek; Smit, Henriëtte A; Daviglus, Martha L; van der Schouw, Yvonne T; Verschuren, W M Monique

    2016-01-13

    The associations between overall lifestyle profile and cardiovascular disease (CVD) and death have been mainly investigated in cross-sectional studies. The full benefits of a healthy lifestyle may therefore be underestimated, and the magnitude of benefits associated with changes in lifestyle remains unclear. We quantified the association of changes in lifestyle profiles over 5 years with risk of CVD and all-cause mortality. Lifestyle factors (ie, diet, physical activity, smoking, alcohol consumption) and body mass index were assessed and dichotomized as healthy/unhealthy among 5263 adults ages 26 to 66 in 1993-1997 and 5 years later (1998-2002). Multivariable-adjusted hazard ratios (HRs) and corresponding 95% confidence intervals (CIs) were estimated to quantify associations of change in lifestyle with fatal/nonfatal CVD and all-cause mortality that occurred 8 to 15 years after 1998-2002. Independent of baseline lifestyles, each decrement in number of healthy lifestyle factors was, on average, associated with 35% higher risk of CVD (HR, 1.35; 95% CI, 1.12-1.63) and 37% higher risk of all-cause mortality (HR, 1.37; 95% CI, 1.10-1.70); no association was noted with increase in the number of healthy lifestyle factors (P>0.5). Individuals who maintained 4 to 5 healthy lifestyle factors had 2.5 times lower risk of CVD (HR, 0.43; 95% CI, 0.25-0.63) and all-cause mortality (HR, 0.40; 95% CI, 0.22-0.73) than those who maintained only 0 to 1 healthy lifestyle factor. Our findings suggest that the benefits of healthy lifestyles may be easier lost than gained over a 5-year period. This underscores the need for efforts to promote maintenance of healthy lifestyles throughout the life course. © 2016 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  11. Physical and mental health functioning after all-cause and diagnosis-specific sickness absence: a register-linkage follow-up study among ageing employees

    Directory of Open Access Journals (Sweden)

    Minna Mänty

    2017-01-01

    Full Text Available Abstract Background Sickness absence has been shown to be a risk marker for severe future health outcomes, such as disability retirement and premature death. However, it is poorly understood how all-cause and diagnosis-specific sickness absence is reflected in subsequent physical and mental health functioning over time. The aim of this study was to examine the association of all-cause and diagnosis-specific sickness absence with subsequent changes in physical and mental health functioning among ageing municipal employees. Methods Prospective survey and register data from the Finnish Helsinki Health Study and the Social Insurance Institution of Finland were used. Register based records for medically certified all-cause and diagnostic-specific sickness absence spells (>14 consecutive calendar days in 2004–2007 were examined in relation to subsequent physical and mental health functioning measured by Short-Form 36 questionnaire in 2007 and 2012. In total, 3079 respondents who were continuously employed over the sickness absence follow-up were included in the analyses. Repeated-measures analysis was used to examine the associations. Results During the 3-year follow-up, 30% of the participants had at least one spell of medically certified sickness absence. All-cause sickness absence was associated with lower subsequent physical and mental health functioning in a stepwise manner: the more absence days, the poorer the subsequent physical and mental health functioning. These differences remained but narrowed slightly during the follow-up. Furthermore, the adverse association for physical health functioning was strongest among those with sickness absence due to diseases of musculoskeletal or respiratory systems, and on mental functioning among those with sickness absence due to mental disorders. Conclusions Sickness absence showed a persistent adverse stepwise association with subsequent physical and mental health functioning. Evidence on health

  12. Physical and mental health functioning after all-cause and diagnosis-specific sickness absence: a register-linkage follow-up study among ageing employees.

    Science.gov (United States)

    Mänty, Minna; Lallukka, Tea; Lahti, Jouni; Pietiläinen, Olli; Laaksonen, Mikko; Lahelma, Eero; Rahkonen, Ossi

    2017-01-25

    Sickness absence has been shown to be a risk marker for severe future health outcomes, such as disability retirement and premature death. However, it is poorly understood how all-cause and diagnosis-specific sickness absence is reflected in subsequent physical and mental health functioning over time. The aim of this study was to examine the association of all-cause and diagnosis-specific sickness absence with subsequent changes in physical and mental health functioning among ageing municipal employees. Prospective survey and register data from the Finnish Helsinki Health Study and the Social Insurance Institution of Finland were used. Register based records for medically certified all-cause and diagnostic-specific sickness absence spells (>14 consecutive calendar days) in 2004-2007 were examined in relation to subsequent physical and mental health functioning measured by Short-Form 36 questionnaire in 2007 and 2012. In total, 3079 respondents who were continuously employed over the sickness absence follow-up were included in the analyses. Repeated-measures analysis was used to examine the associations. During the 3-year follow-up, 30% of the participants had at least one spell of medically certified sickness absence. All-cause sickness absence was associated with lower subsequent physical and mental health functioning in a stepwise manner: the more absence days, the poorer the subsequent physical and mental health functioning. These differences remained but narrowed slightly during the follow-up. Furthermore, the adverse association for physical health functioning was strongest among those with sickness absence due to diseases of musculoskeletal or respiratory systems, and on mental functioning among those with sickness absence due to mental disorders. Sickness absence showed a persistent adverse stepwise association with subsequent physical and mental health functioning. Evidence on health-related outcomes after long-term sickness absence may provide useful

  13. Age-adjusted Charlson Comorbidity Index scores predict major adverse cardiovascular events and all-cause mortality among systemic lupus erythematosus patients

    Directory of Open Access Journals (Sweden)

    Mei-Hua Chuang

    2017-01-01

    Full Text Available Objective: Cardiovascular events are the most frequent cause of death or disability among people with systemic lupus erythematosus (SLE. However, the causes of this increased the risk of major adverse cardiovascular events (MACEs are not completely understood. The Age-adjusted Charlson Comorbidity Index (ACCI is a prognostic classification that was initially developed for patients who have a number of comorbid conditions and the ACCI has been validated in many clinical settings. Materials and Methods: In this study, 5998 patients were enrolled from the National Health Research Institute Database of Taiwan. All the patients' sequential clinical data related to their diagnosis of SLE were reviewed from 2004 to 2007 to determine their risk of MACE occurrence and of all-cause mortality using their ACCI scores. Results: The predictive accuracy of the ACCI scores in relation to MACE occurrence among SLE patients was estimated and the C-statistic for this curve was found to be 0.687 (95% confidence interval [CI]: 0.664–0.709. The distribution of ACCI scores for MACE patients was 4.7%, 10.3%, 11.4%, and 21.5% for those with ACCI scores in the ranges of 0–1, 2–3, 4–5, and >6, respectively. A plot of the cumulative risk also showed a much higher risk among SLE patients with an ACCI score of >6. When patients were divided into different groups based on their ACCI scores, those with ACCI scores of >6 had an adjusted hazards ratio of 4.88 (95% CI: 3.84–6.19;P< 0.001 as compared to those with ACCI scores of 0–1. Conclusion: SLE patients with higher ACCI scores have a significantly higher risk of a MACE and of all-cause mortality. Our results suggested that ACCI scores may be useful as an index for estimating global cardiovascular risk among patients with SLE.

  14. Note: Improved wire-wound heater.

    Science.gov (United States)

    Steinmann, Ricardo G; Vitoux, Hugo

    2015-01-01

    The authors have measured, at cryogenic temperature, the upper limit of the heat transfer in different configurations of a wire-wound heater. We found that the heat transferred has an upper limit of about 15 W/cm(2) and is dependent on the diameter of the wire. In this paper, we present three ways of increasing the heat transferred by this type of heater and its application in different continuous flow cryostats.

  15. Graphene wire medium: Homogenization and application

    DEFF Research Database (Denmark)

    Andryieuski, Andrei; Chigrin, Dmitry N.; Lavrinenko, Andrei

    2012-01-01

    In this contribution we analyze numerically the optical properties of the graphene wire medium, which unit cell consists of a stripe of graphene embedded into dielectric. We propose a simple method for retrieval of the isofrequency contour and effective permittivity tensor. As an example...... of the graphene wire medium application we demonstrate a reconfigurable hyperlens for the terahertz subwavelength imaging capable of resolving two sources with separation λ0/5 in the far-field....

  16. Novel use of the "buddy"wire.

    LENUS (Irish Health Repository)

    O'Hare, A

    2008-12-29

    Summary: During interventional procedures the tortuosity of the vasculature hampers catheter stability. The buddy wire may be used to aid and maintain vascular access.We describe a case of acute subarachnoid haemorrhage secondary to dissecting aneurysm of the vertebral artery.We discuss the value of the buddy wire during balloon occlusion of the vertebral artery not as it is typically used, but to actually prevent the balloon repeatedly entering the posterior inferior cerebellar artery during the procedure.

  17. A Magnetic Sensor with Amorphous Wire

    Directory of Open Access Journals (Sweden)

    Dongfeng He

    2014-06-01

    Full Text Available Using a FeCoSiB amorphous wire and a coil wrapped around it, we have developed a sensitive magnetic sensor. When a 5 mm long amorphous wire with the diameter of 0.1 mm was used, the magnetic field noise spectrum of the sensor was about 30 pT/ÖHz above 30 Hz. To show the sensitivity and the spatial resolution, the magnetic field of a thousand Japanese yen was scanned with the magnetic sensor.

  18. COBRA-IV wire wrap data comparisons

    International Nuclear Information System (INIS)

    Donovan, T.E.; George, T.L.; Wheeler, C.L.

    1979-02-01

    Thermal hydraulic analyses of hexagonally packed wire-wrapped fuel assemblies are complicated by the induced crossflow between adjacent subchannels. The COBRA-IV computer code simultaneously solves the hydrodynamics and thermodynamics of fuel assemblies. The modifications and the results are presented which are predicted by the COBRA-IV calculation. Comparisons are made with data measured in five experimental models of a wire-wrapped fuel assembly

  19. Subchannel Analysis of Wire Wrapped SCWR Assembly

    Directory of Open Access Journals (Sweden)

    Jianqiang Shan

    2014-01-01

    Full Text Available Application of wire wrap spacers in SCWR can reduce pressure drop and obtain better mixing capability. As a consequence, the required coolant pumping power is decreased and the coolant temperature profile inside the fuel bundle is flattened which will obviously decrease the peak cladding temperature. The distributed resistance model for wire wrap was developed and implemented in ATHAS subchannel analysis code. The HPLWR wire wrapped assembly was analyzed. The results show that: (1 the assembly with wire wrap can obtain a more uniform coolant temperature profile than the grid spaced assembly, which will result in a lower peak cladding temperature; (2 the pressure drop in a wire wrapped assembly is less than that in a grid spaced assembly, which can reduce the operating power of pump effectively; (3 the wire wrap pitch has significant effect on the flow in the assembly. Smaller Hwire/Drod will result in stronger cross flow a more uniform coolant temperature profile, and also a higher pressure drop.

  20. Superconducting wires and methods of making thereof

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Xingchen; Sumption, Michael D.; Peng, Xuan

    2018-03-13

    Disclosed herein are superconducting wires. The superconducting wires can comprise a metallic matrix and at least one continuous subelement embedded in the matrix. Each subelement can comprise a non-superconducting core, a superconducting layer coaxially disposed around the non-superconducting core, and a barrier layer coaxially disposed around the superconducting layer. The superconducting layer can comprise a plurality of Nb.sub.3Sn grains stabilized by metal oxide particulates disposed therein. The Nb.sub.3Sn grains can have an average grain size of from 5 nm to 90 nm (for example, from 15 nm to 30 nm). The superconducting wire can have a high-field critical current density (J.sub.c) of at least 5,000 A/mm.sup.2 at a temperature of 4.2 K in a magnetic field of 12 T. Also described are superconducting wire precursors that can be heat treated to prepare superconducting wires, as well as methods of making superconducting wires.

  1. Si Wire-Array Solar Cells

    Science.gov (United States)

    Boettcher, Shannon

    2010-03-01

    Micron-scale Si wire arrays are three-dimensional photovoltaic absorbers that enable orthogonalization of light absorption and carrier collection and hence allow for the utilization of relatively impure Si in efficient solar cell designs. The wire arrays are grown by a vapor-liquid-solid-catalyzed process on a crystalline (111) Si wafer lithographically patterned with an array of metal catalyst particles. Following growth, such arrays can be embedded in polymethyldisiloxane (PDMS) and then peeled from the template growth substrate. The result is an unusual photovoltaic material: a flexible, bendable, wafer-thickness crystalline Si absorber. In this paper I will describe: 1. the growth of high-quality Si wires with controllable doping and the evaluation of their photovoltaic energy-conversion performance using a test electrolyte that forms a rectifying conformal semiconductor-liquid contact 2. the observation of enhanced absorption in wire arrays exceeding the conventional light trapping limits for planar Si cells of equivalent material thickness and 3. single-wire and large-area solid-state Si wire-array solar cell results obtained to date with directions for future cell designs based on optical and device physics. In collaboration with Michael Kelzenberg, Morgan Putnam, Joshua Spurgeon, Daniel Turner-Evans, Emily Warren, Nathan Lewis, and Harry Atwater, California Institute of Technology.

  2. Needleless electrospinning with twisted wire spinneret

    International Nuclear Information System (INIS)

    Holopainen, Jani; Penttinen, Toni; Santala, Eero; Ritala, Mikko

    2015-01-01

    A needleless electrospinning setup named ‘Needleless Twisted Wire Electrospinning’ was developed. The polymer solution is electrospun from the surface of a twisted wire set to a high voltage and collected on a cylindrical collector around the wire. Multiple Taylor cones are simultaneously self-formed on the downward flowing solution. The system is robust and simple with no moving parts aside from the syringe pump used to transport the solution to the top of the wire. The structure and process parameters of the setup and the results on the preparation of polyvinyl pyrrolidone (PVP), hydroxyapatite (HA) and bioglass fibers with the setup are presented. PVP fiber sheets with areas of 40 × 120 cm 2 and masses up to 1.15 g were prepared. High production rates of 5.23 g h −1 and 1.40 g h −1 were achieved for PVP and HA respectively. The major limiting factor of the setup is drying of the polymer solution on the wire during the electrospinning process which will eventually force to interrupt the process for cleaning of the wire. Possible solutions to this problem and other ways to develop the setup are discussed. The presented system provides a simple way to increase the production rate and area of fiber sheet as compared with the conventional needle electrospinning. (paper)

  3. 75 FR 60480 - In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire...

    Science.gov (United States)

    2010-09-30

    ... COMMISSION In the Matter of Certain Bulk Welding Wire Containers and Components Thereof and Welding Wire... importation, or the sale within the United States after importation of certain bulk welding wire containers, components thereof, and welding wire by reason of infringement of certain claims of United States Patent Nos...

  4. Empolder and application of LiveWire program

    International Nuclear Information System (INIS)

    Zhang Bo; Li Jing; Wang Xiaoming

    2007-01-01

    LiveWire is a specific module of Netscape Web server to actualize CGI function; through LiveWire application program one can create dynamic web page on web site. This article introduces how to write LiveWire application code, have to compile, debug and manage LiveWire application programs, and how to apply LiveWire application program on Netscape Web server to create a dynamic web page. (authors)

  5. Wiring design for the control of electromagnetic interference (EMI)

    Science.gov (United States)

    Kopasakis, George

    1995-01-01

    Wiring design is only one important aspect of EMI control. Other important areas for EMI are: circuit design, filtering, grounding, bonding, shielding, lighting, electrostatic discharge (ESD), transient suppression, and electromagnetic pulse (EMP). Topics covered include: wire magnetic field emissions at low frequencies; wire radiated magnetic field emissions at frequencies; wire design guidelines for EMI control; wire design guidelines for EMI control; high frequency emissions from cables; and pulse frequency spectra.

  6. Burden of total and cause-specific mortality related to tobacco smoking among adults aged ≥ 45 years in Asia: a pooled analysis of 21 cohorts.

    Directory of Open Access Journals (Sweden)

    Wei Zheng

    2014-04-01

    Full Text Available Tobacco smoking is a major risk factor for many diseases. We sought to quantify the burden of tobacco-smoking-related deaths in Asia, in parts of which men's smoking prevalence is among the world's highest.We performed pooled analyses of data from 1,049,929 participants in 21 cohorts in Asia to quantify the risks of total and cause-specific mortality associated with tobacco smoking using adjusted hazard ratios and their 95% confidence intervals. We then estimated smoking-related deaths among adults aged ≥45 y in 2004 in Bangladesh, India, mainland China, Japan, Republic of Korea, Singapore, and Taiwan-accounting for ∼71% of Asia's total population. An approximately 1.44-fold (95% CI = 1.37-1.51 and 1.48-fold (1.38-1.58 elevated risk of death from any cause was found in male and female ever-smokers, respectively. In 2004, active tobacco smoking accounted for approximately 15.8% (95% CI = 14.3%-17.2% and 3.3% (2.6%-4.0% of deaths, respectively, in men and women aged ≥45 y in the seven countries/regions combined, with a total number of estimated deaths of ∼1,575,500 (95% CI = 1,398,000-1,744,700. Among men, approximately 11.4%, 30.5%, and 19.8% of deaths due to cardiovascular diseases, cancer, and respiratory diseases, respectively, were attributable to tobacco smoking. Corresponding proportions for East Asian women were 3.7%, 4.6%, and 1.7%, respectively. The strongest association with tobacco smoking was found for lung cancer: a 3- to 4-fold elevated risk, accounting for 60.5% and 16.7% of lung cancer deaths, respectively, in Asian men and East Asian women aged ≥45 y.Tobacco smoking is associated with a substantially elevated risk of mortality, accounting for approximately 2 million deaths in adults aged ≥45 y throughout Asia in 2004. It is likely that smoking-related deaths in Asia will continue to rise over the next few decades if no effective smoking control programs are implemented. Please see later in the article for

  7. Gold-wire artifacts on diagnostic radiographs: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Keestra, Johan Anton Jochum; Jacobs, Reinhilde; Quirynen, Marc [Dept. of Oral Health Sciences, KU Leuven and Dentistry, University Hospitals, KU Leuven, Leuven (Belgium)

    2014-03-15

    This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

  8. Gold-wire artifacts on diagnostic radiographs: A case report

    International Nuclear Information System (INIS)

    Keestra, Johan Anton Jochum; Jacobs, Reinhilde; Quirynen, Marc

    2014-01-01

    This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

  9. [How reliable is a hot-wire anemometer?].

    Science.gov (United States)

    von Rechenberg, H; Konder, H; Höser, K; Lennartz, H

    1985-08-01

    To examine the advantage of hot-wire anemometer for clinical use, we have checked two types of this tools with respect to reliability and validity. It was found that electronic suppression of noise caused a distortion of the measurements. Furthermore changes of transducers were also responsible for deviations from true values. We require of the manufacturer to indicate the threshold of perception and the coefficient of variation for repeated measurements with several transducers. We recommend a simple rule which permits an estimation of the limits of reliable measurements for clinical use depending on the threshold of the equipment and on the parameters of ventilation.

  10. [Population frequency and age of mutation G5741→A in gene NBAS which is a cause of SOPH syndrome in Sakha (Yakutia) Republic].

    Science.gov (United States)

    Maksimova, N R; Nogovicina, A N; Kurtanov, Kh A; Alekseeva, E I

    2016-10-01

    SOPH syndrome (Short stature with Optic nerve atrophy and Pelger–Huët anomaly syndrome, OMIM#614800) is an autosomal recessive hereditary disease characterized by the following main clinical symptoms: postnatal hypoplasia, proportionately short stature, facial dysmorphism, micromelia of feet and hands, limp and loose skin, optic nerve atrophy, and Pelger–Huët anomaly of neutrophils. For the first time, this disease was described in Yakuts. The molecular-genetic study showed that its cause in Yakuts is mutation G5741→A in gene NBAS. On the basis of disequilibrium analysis for linkage of ten microsatellite markers flanking the NBAS gene with the disease, the haplotype of the founder chromosome was determined. The age of the mutation in Yakutia was estimated to be about 804 ± 140 years. The frequency of heterozygous carriers of mutation G5741→A (R1914H) in gene NBAS was found, which averaged 13 per 1000 healthy Yakuts.

  11. Early loosening and secondary dislocation due to a broken trochanteric osteotomy wire following a Charnley total hip arthroplasty: a case report

    OpenAIRE

    Shahin, Yousef; Choudhary, Rakesh; Al-Naser, Saeed; Mullins, Mark

    2009-01-01

    We report a case of interposition of a broken trochanteric wire in the hip joint. This caused early wear of the prosthesis and dislocation of the Charnley total hip arthroplasty. The patient was treated with a revision total hip arthroplasty. This rare complication should be taken into consideration when performing a trochanteric osteotomy fixation with wiring in Charnley total hip arthroplasty.

  12. Synergistic effects of cognitive impairment on physical disability in all-cause mortality among men aged 80 years and over: Results from longitudinal older veterans study.

    Science.gov (United States)

    Yu, Wan-Chen; Chou, Ming-Yueh; Peng, Li-Ning; Lin, Yu-Te; Liang, Chih-Kuang; Chen, Liang-Kung

    2017-01-01

    risk factor for all-cause mortality among men aged 80 years and older, and risk increased synergistically when cognitive impairment was present. Cognitive impairment alone without physical disability did not increase mortality risk in this population.

  13. Synergistic effects of cognitive impairment on physical disability in all-cause mortality among men aged 80 years and over: Results from longitudinal older veterans study.

    Directory of Open Access Journals (Sweden)

    Wan-Chen Yu

    is a major risk factor for all-cause mortality among men aged 80 years and older, and risk increased synergistically when cognitive impairment was present. Cognitive impairment alone without physical disability did not increase mortality risk in this population.

  14. Mixed and dynamic response of hot wires and cold wires and measurements of turbulence statistics

    DEFF Research Database (Denmark)

    Larsen, Søren Ejling; Højstrup, Jørgen; Fairall, C. W.

    1986-01-01

    Hot wires respond to temperature as well as to velocity, whereas cold wires respond to velocity as well as to temperature. The static and dynamic response characteristics are summarized and it is shown that the frequency transfer functions for the four different responses in general are different...

  15. Modeling and simulation of the fluid flow in wire electrochemical machining with rotating tool (wire ECM)

    Science.gov (United States)

    Klocke, F.; Herrig, T.; Zeis, M.; Klink, A.

    2017-10-01

    Combining the working principle of electrochemical machining (ECM) with a universal rotating tool, like a wire, could manage lots of challenges of the classical ECM sinking process. Such a wire-ECM process could be able to machine flexible and efficient 2.5-dimensional geometries like fir tree slots in turbine discs. Nowadays, established manufacturing technologies for slotting turbine discs are broaching and wire electrical discharge machining (wire EDM). Nevertheless, high requirements on surface integrity of turbine parts need cost intensive process development and - in case of wire-EDM - trim cuts to reduce the heat affected rim zone. Due to the process specific advantages, ECM is an attractive alternative manufacturing technology and is getting more and more relevant for sinking applications within the last few years. But ECM is also opposed with high costs for process development and complex electrolyte flow devices. In the past, few studies dealt with the development of a wire ECM process to meet these challenges. However, previous concepts of wire ECM were only suitable for micro machining applications. Due to insufficient flushing concepts the application of the process for machining macro geometries failed. Therefore, this paper presents the modeling and simulation of a new flushing approach for process assessment. The suitability of a rotating structured wire electrode in combination with an axial flushing for electrodes with high aspect ratios is investigated and discussed.

  16. STRS SpaceWire FPGA Module

    Science.gov (United States)

    Lux, James P.; Taylor, Gregory H.; Lang, Minh; Stern, Ryan A.

    2011-01-01

    An FPGA module leverages the previous work from Goddard Space Flight Center (GSFC) relating to NASA s Space Telecommunications Radio System (STRS) project. The STRS SpaceWire FPGA Module is written in the Verilog Register Transfer Level (RTL) language, and it encapsulates an unmodified GSFC core (which is written in VHDL). The module has the necessary inputs/outputs (I/Os) and parameters to integrate seamlessly with the SPARC I/O FPGA Interface module (also developed for the STRS operating environment, OE). Software running on the SPARC processor can access the configuration and status registers within the SpaceWire module. This allows software to control and monitor the SpaceWire functions, but it is also used to give software direct access to what is transmitted and received through the link. SpaceWire data characters can be sent/received through the software interface, as well as through the dedicated interface on the GSFC core. Similarly, SpaceWire time codes can be sent/received through the software interface or through a dedicated interface on the core. This innovation is designed for plug-and-play integration in the STRS OE. The SpaceWire module simplifies the interfaces to the GSFC core, and synchronizes all I/O to a single clock. An interrupt output (with optional masking) identifies time-sensitive events within the module. Test modes were added to allow internal loopback of the SpaceWire link and internal loopback of the client-side data interface.

  17. Mechanical eye injuries in children aged 0-15 years treated at the Clinic of Eye Diseases in Belgrade: Frequency, causes and preventive measures

    Directory of Open Access Journals (Sweden)

    Jovanović Miloš

    2013-01-01

    Full Text Available Introduction. Eye injuries represent a significant problem in children. Objective. The aim of the study was to determine the incidence and causes of the eye injury and to propose measures of the eye injury prevention in children up to 15 years of age. Methods. This was a retrospective study of 552 children with the eye injuries treated at the Clinic of Eye Diseases in Belgrade during the period March 1999 to February 2010. Gender and age of the children, time of injury, the type and site of injuries, visual acuity upon admission and at discharge, as well as the time of surgery in relation to time of injury were analyzed. Results. The ratio between the injured boys and girls was 3.6:1. The highest percentage of injured children was in the group 6-10 years old (39.7%; the injuries were almost evenly distributed according to months during the year and days during the week. The percentages of severe closed and open injuries of the eyeball were almost equal. Visual acuity upon discharge and subsequent follow-up examinations were significantly improved after the applied treatment in comparison with the visual acuity upon admission. Conclusion. Eye injuries in children still represent a severe health problem. Regarding the youngest age group of children, adults are mainly responsible for these injuries due to their lack of attention, while in older children these injuries are the result of the production and distribution of inappropriate toys and a failure to implement the legal traffic regulations applicable to children. The prevention of eye injuries is essential.

  18. The 'Displacing Foods of Modern Commerce' Are the Primary and Proximate Cause of Age-Related Macular Degeneration: A Unifying Singular Hypothesis.

    Science.gov (United States)

    Knobbe, Chris A; Stojanoska, Marija

    2017-11-01

    Age-related macular degeneration (AMD) is the leading cause of irreversible vision loss and blindness in developed nations. AMD is anticipated to affect 196 million people worldwide, by 2020. However, the etiology of this disease remains unknown. Aging, genetic, and environmental influences have generally been implicated as major etiologic factors. We sought to examine the hypothesis that consumption of the 'displacing foods of modern commerce,' which equate to processed, nutrient-deficient and potentially toxic foods, may be the primary and proximate cause of AMD. To evaluate this hypothesis, we ran correlative AMD prevalence data against well-known proxy markers of processed food consumption, namely, sugar and vegetable oils, in 25 nations. In twenty-one nations, published studies provided AMD prevalence data and in four Pacific Island nations, practicing ophthalmologists in the regions completed retrospective chart analyses to estimate AMD prevalence in their respective regions. To estimate AMD prevalence historically, an extensive review of published papers and ophthalmic literature was completed. This review indicates that, between the years 1851 and 1930, AMD was a medical rarity worldwide, which then rose modestly in prevalence in the 1930s in the U.S. and U.K, finally elevating to epidemic proportions by 1975 in the U.S. Numerous developed nations have followed suit in recent decades. Simultaneously, between approximately 1880 and 2009, processed, nutrient-deficient foods gradually supplanted and displaced whole, unprocessed, nutrient-dense foods in developed nations, such that by 2009, 63 percent of the American diet was made up of nutrient-deficient foods in the form of refined white flour, added sugars, vegetable oils, and artificially created trans fats. The correlative data in 25 nations shows that increasing sugar and polyunsaturated vegetable oil consumption is invariably associated with new onset or rising prevalence of AMD, generally within about

  19. Strength of stainless steel surgical wire in various fixation modes.

    Science.gov (United States)

    Schultz, R S; Boger, J W; Dunn, H K

    1985-09-01

    Although wire is a commonly used fixation device in orthopedics, little is known about the effects of fastening methods and configurations on the strength of wiring systems. Three sizes of stainless steel surgical wire were tested in noncyclic tensile loading. Load failure levels increased with enlarging wire diameter. Fastening twists were stronger than knots or the ASIF bend technique. The failure mode for twists was untwisting. More than two twists gave no additional strength to the system. Two commercial wire tightening devices gave stronger and more reproducible twists than did ordinary pliers. The addition of a tension equalizing loop opposite the fastening loop weakened the wire system by 10%-15%. The combination of two single wire loops was stronger than a continuous double loop of wire. The results from this study are intended to help the orthopedic surgeon optimize the use of wire.

  20. Electric cables and wires: dimensioning for energy conservation; Fios e cabos eletricos: dimensionamento para conservacao da energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Borges Neto, Antonio Goncalves; Pereto, Antonio Soares; Silva, Ricardo Carvalho da [Companhia de Saneamento Basico do Estado de Sao Paulo (SABESP), Sao Paulo, SP (Brazil)

    1994-12-31

    Electric cables and wires are essential in any type of electric installation, usually in large quantities. This work emphasis the need to devote special attention to electric power costs therefore it is sometimes advantageous to use over-dimensions electric cables and wires with favorable results. According to the authors, just to meet the Brazilian standards may cause future costs 6 refs., 5 graphs., 1 tab.

  1. Integrated Electrical Wire Insulation Repair System

    Science.gov (United States)

    Williams, Martha; Jolley, Scott; Gibson, Tracy; Parks, Steven

    2013-01-01

    An integrated system tool will allow a technician to easily and quickly repair damaged high-performance electrical wire insulation in the field. Low-melt polyimides have been developed that can be processed into thin films that work well in the repair of damaged polyimide or fluoropolymer insulated electrical wiring. Such thin films can be used in wire insulation repairs by affixing a film of this low-melt polyimide to the damaged wire, and heating the film to effect melting, flow, and cure of the film. The resulting repair is robust, lightweight, and small in volume. The heating of this repair film is accomplished with the use of a common electrical soldering tool that has been modified with a special head or tip that can accommodate the size of wire being repaired. This repair method can furthermore be simplified for the repair technician by providing replaceable or disposable soldering tool heads that have repair film already "loaded" and ready for use. The soldering tool heating device can also be equipped with a battery power supply that will allow its use in areas where plug-in current is not available

  2. EVALUATION OF INDUCTANCE WITH ELECTRICAL WIRES

    Directory of Open Access Journals (Sweden)

    V. Kudry

    2016-08-01

    Full Text Available In this paper proved the possibility of developing passive electronic inductive elements based replace metal wire that is wound inductor, the wire is made of electret. The relative permeability of the electret S  10 000, several orders of magnitude greater than the permeability of conventional insulation materials, i < 10, resulting current in the wire acquires properties bias current. The essence of innovation is to replace the source of of magnetic induction flow that pervades the core of the coil. According to the theory of electrodynamics, current bias, in contrast to conduction current, generated no movement of charge along the wire, but the change of the charge in the local volume.Equivalence bias current and conduction current is manifested in the possibility of forming a magnetic field. The flow through magnetic induction coil core regardless of the current it generates, creates voltage at its ends.The paper also shows the numeric characteristics that determine the effective frequency range, specified the reason why electric a wire with і < 10 can not generate magnetic flux through the core and serve as a passive reactive component.

  3. Efficacy of Esthetic Retainers: Clinical Comparison between Multistranded Wires and Direct-Bond Glass Fiber-Reinforced Composite Splints

    Science.gov (United States)

    Scribante, Andrea; Sfondrini, Maria Francesca; Broggini, Simona; D'Allocco, Marina; Gandini, Paola

    2011-01-01

    The purpose of this longitudinal prospective randomized study was to evaluate the reliability of two different types of orthodontic retainers in clinical use: a multistrand stainless steel wire and a polyethylene ribbon-reinforced resin composite. Moreover the level of satisfaction of the patient about the esthetic result was also analyzed by means of a Visual Analogue Scale (VAS). 34 patients (9 boys and 25 girls, mean age 14.3), in the finishing phase of orthodontic treatment, were selected for the study. Since splints were applied the number, cause, and date of splint failures were recorded for each single tooth over 12 months. Statistical analysis was performed using a paired t-test, Kaplan Meier survival estimates, and the log-rank test. Kruskal Wallis test was performed to analyze VAS recordings. Differences between the bond failure rates were not statistically significant. Esthetic result of VAS was significantly higher for polyethylene ribbon-reinforced resin retainers than for stainless steel wires. PMID:22114597

  4. Effect of Size on Tensile Strength of Fine Polycrystalline Nickel Wires

    National Research Council Canada - National Science Library

    Rubenstein, Lester

    1966-01-01

    .... The tensile strength of recrystallized wires was diameter independent. The proportional limit stress of recrystallized wires was inversely related to power functions of wire diameter and grain size...

  5. Uniaxial Strain Induced Critical Current Degradation of Ag-Sheathed Bi-2212 Round Wire

    NARCIS (Netherlands)

    Dai, Chao; Qin, Jinggang; Liu, Bo; Liu, Peihang; Wu, Yu; Nijhuis, Arend; Zhou, Chao; Li, Chenshan; Hao, Qingbin; Liu, Sheng

    2018-01-01

    The critical current degradation of Bi-2212 Ag-sheathed round wire subjected to uniaxial strain was studied at 4.2 K in 14 T background field. The strains applied on the sample are both tension and compression. The additional tensile strain caused by the difference in thermal expansion between the

  6. Studying an inexpensive wire discone antenna as a candidate for TVWS spectrum monitoring / sensing

    CSIR Research Space (South Africa)

    Lysko, AA

    2014-10-01

    Full Text Available . Correctly identifying available TVWS bands is critical for success of TVWS based broadband communications, not causing interference to reception of TV broadcast by TV receivers. This paper discusses side effects encountered with a popular design of a wire...

  7. The development of ShortWatch, a novel overtemperature or mechanical damage sensing technology for wires or cables. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, Ken; Morris, Jack; Wong, C.P.; Luo, Shijian

    2001-09-07

    'ShortWatch' is a patented technology which for the first time offers electrical wire/cable products providing real-time, 'in-situ' (1) condition monitoring that warns of insulation damage before an electrical fault occurs, (2) assessment of the ability to perform in a Design Basis event, (3) distributed sensor warning of overtemperature, and (4) insulation leakage measurement capability providing arc sensing and a reliable tool for wire age prediction.

  8. Magnetic wires in MEMS and bio-medical applications

    International Nuclear Information System (INIS)

    Barbic, Mladen

    2002-01-01

    Magnetic wires of appropriate design have special features making them useful to micro-electromechanical systems and bio-medical applications. Several applications that exploit the properties of magnetic wires are reviewed including: (a) a magnetic micro-manipulation technique that utilizes integrated micro-coils and magnetic micro-wires for localized positioning of micron-sized magnetic objects, (b) integrated micro-coil/micro-wire system operating as a micro-fluidic micro-motor, (c) mechanical tweezers using magneto-static interaction between two magnetic micro-wires, and (d) ultra-high gradient magnetic separation system based on porous membranes partially filled with magnetic wires

  9. A comparison of a 'J' wire and a straight wire in successful antegrade cannulation of the superficial femoral artery

    International Nuclear Information System (INIS)

    Gay, D.A.T.; Edwards, A.J.; Puckett, M.A.; Roobottom, C.A.

    2005-01-01

    AIMS: To evaluate the success of two different types of wire in common use in their ability to successfully cannulate the superficial femoral artery (SFA) using antegrade puncture. METHODS: 50 consecutive patients in whom antegrade infra-inguinal intervention was planned, underwent common femoral arterial puncture and then cannulation with either a standard 3 mm 'J' wire or a floppy tipped straight wire (William Cook--Europe). The frequency with which each type of wire entered the SFA or profunda femoris artery without image guidance was recorded. Further analysis was also made of the success of manipulation of the wire into the SFA following profunda cannulation and the use of alternative guide wires. RESULTS: In 19 out of 25 (76%) patients the 'J' wire correctly entered the SFA without image guidance. Only 5 out of 25 (25%) of straight wires entered the SFA with the initial pass (p<0.0001). Following further manipulation with the same wire all except 1 'J' wire was successfully negotiated into the SFA. The same was true for only 9 of the remaining straight wires with 11 patients requiring an alternative guide wire. CONCLUSIONS: When performing antegrade cannulation of the SFA a 'J' wire is more likely to be successful than a straight guide wire

  10. Cockpit canopy shattering using exploding wire techniques

    International Nuclear Information System (INIS)

    Novac, B M; Smith, I R; Downs, P R; Marston, P; Fahey, D

    2007-01-01

    This paper presents the principal experimental results provided by a preliminary investigation into the possibility of using exploding wire (EW) techniques to shatter the plastic cockpit canopy of a modern jet aircraft. The data provided forms the basis for a qualitative understanding of the physics of interaction between the plasma produced by an EW and the surrounding elasto-plastic material in which the wire is embedded. To optimize the shock-wave 'clean cutting' effect, the significance of the material, the dimensions of the exploding wire and the amplitude of the current and voltage pulses are all considered. This leads to important conclusions concerning both the characteristics of the EW and the optimum arrangement of the electrical circuit, with the single most important optimization factor being the peak electrical power input to the EW, rather than the dissipated Joule energy. A full-scale system relevant to an actual cockpit canopy shattering is outlined and relevant results are presented and discussed

  11. Reusable Hot-Wire Cable Cutter

    Science.gov (United States)

    Pauken, Michael T.; Steinkraus, Joel M.

    2010-01-01

    During the early development stage of balloon deployment systems for missions, nichrome wire cable cutters were often used in place of pyro-actuated cutters. Typically, a nichrome wire is wrapped around a bundle of polymer cables with a low melting point and connected to a relay-actuated electric circuit. The heat from the nichrome reduces the strength of the cable bundle, which quickly breaks under a mechanical load and can thus be used as a release mechanism for a deployment system. However, the use of hand-made heated nichrome wire for cutters is not very reliable. Often, the wrapped nichrome wire does not cut through the cable because it either pulls away from its power source or does not stay in contact with the cable being cut. Because nichrome is not readily soldered to copper wire, unreliable mechanical crimps are often made to connect the nichrome to an electric circuit. A self-contained device that is reusable and reliable was developed to sever cables for device release or deployment. The nichrome wire in this new device is housed within an enclosure to prevent it from being damaged by handling. The electric power leads are internally connected within the unit to the nichrome wire using a screw terminal connection. A bayonet plug, a quick and secure method of connecting the cutter to the power source, is used to connect the cutter to the power leads similar to those used in pyro-cutter devices. A small ceramic tube [0.25-in. wide 0.5-in. long (.6.4-mm wide 13-mm long)] houses a spiraled nichrome wire that is heated when a cable release action is required. The wire is formed into a spiral coil by wrapping it around a mandrel. It is then laid inside the ceramic tube so that it fits closely to the inner surface of the tube. The ceramic tube provides some thermal and electrical insulation so that most of the heat generated by the wire is directed toward the cable bundle in the center of the spiral. The ceramic tube is cemented into an aluminum block, which

  12. Inactivation of the Rcan2 gene in mice ameliorates the age- and diet-induced obesity by causing a reduction in food intake.

    Directory of Open Access Journals (Sweden)

    Xiao-yang Sun

    Full Text Available Obesity is a serious international health problem that increases the risk of several diet-related chronic diseases. The genetic factors predisposing to obesity are little understood. Rcan2 was originally identified as a thyroid hormone-responsive gene. In the mouse, two splicing variants that harbor distinct tissue-specific expression patterns have been identified: Rcan2-3 is expressed predominately in the brain, whereas Rcan2-1 is expressed in the brain and other tissues such as the heart and skeletal muscle. Here, we show that Rcan2 plays an important role in the development of age- and diet-induced obesity. We found that although the loss of Rcan2 function in mice slowed growth in the first few weeks after birth, it also significantly ameliorated age- and diet-induced obesity in the mice by causing a reduction in food intake rather than increased energy expenditure. Rcan2 expression was most prominent in the ventromedial, dorsomedial and paraventricular hypothalamic nuclei governing energy balance. Fasting and refeeding experiment showed that only Rcan2-3 mRNA expression is up-regulated in the hypothalamus by fasting, and loss of Rcan2 significantly attenuates the hyperphagic response to starvation. Using double-mutant (Lep(ob/ob Rcan2(-/- mice, we were also able to demonstrate that Rcan2 and leptin regulate body weight through different pathways. Our findings indicate that there may be an Rcan2-dependent mechanism which regulates food intake and promotes weight gain through a leptin-independent pathway. This study provides novel information on the control of body weight in mice and should improve our understanding of the mechanisms of obesity in humans.

  13. The Role of Overloading on the Reduction of Residual Stress by Cyclic Loading in Cold-Drawn Prestressing Steel Wires

    Directory of Open Access Journals (Sweden)

    Jesús Toribio

    2017-01-01

    Full Text Available Prestressing steel wires are commonly used as reinforcement elements in structures bearing fatigue loads. These wires are obtained by a conforming process called cold drawing, where a progressive reduction of the wire diameter is produced, causing residual stress in the commercial wire. The aim of this paper is to analyze the effect of diverse in-service cyclic loading conditions (cyclic loading and cyclic loading with overload on such a residual stress field. To achieve this goal, firstly, a numerical simulation of the wire drawing process of a commercial prestressing steel wire was carried out to reveal the residual stress state induced by the manufacture technique. Afterwards, a numerical simulation was performed of the in-service loading conditions of a prestressing steel wire in which the previously calculated residual stress state is included. The analysis of the obtained results shows a significant reduction of the residual stress state of about 50% for common in-service loadings and as high as 90% for certain cases undergoing overloads during cyclic loading. Therefore, an improvement of the mechanical performance of these structural components during their life in-service can be achieved.

  14. Use of Kirschner wires with eyelets for tension band wiring of olecranon fractures.

    Science.gov (United States)

    Kim, Jin Young; Lee, Young Ho; Gong, Hyun Sik; Lee, Sang Lim; Lee, Sang Ki; Baek, Goo Hyun

    2013-09-01

    To evaluate the clinical and radiographic outcomes of tension band wiring of displaced olecranon fractures treated using Kirschner wires with eyelets to assess their clinical performance with respect to complications such as backing out of the K-wires, restriction of forearm rotation, and neurovascular injury. The authors retrospectively reviewed 44 patients treated for an isolated, displaced olecranon fracture and checked range of motion, postoperative pain, complications, and incidence of hardware removal. The mean follow-up period was 41 months (range, 26-73 mo). All fractures united, and anatomical reduction was achieved in all cases at final follow-up. Mean elbow flexion was 135° (range, 115° to 140°), and mean elbow extension was 4° (range, 0° to 15°). No pin migration, restriction of forearm rotation, or neurovascular injury occurred. Hardware removal was performed in 8 cases (18%). Compared to previous results with conventional Kirschner wires, no meaningful improvement in postoperative pain level or in the rate of hardware removal was observed. Tension band wiring using the pin studied produced excellent clinical and radiologic outcomes for the treatment of isolated, displaced Mayo type IIA and some type IIB olecranon fractures. The pin was effective in preventing the backing out of Kirschner wires and avoiding the complications associated with anterior cortical engagement of Kirschner wires, such as neurovascular injury or restriction of forearm rotation. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Investigation of method for Stainless Steel Welding Wire as a Replacement for Arc Wire Comsumables

    Directory of Open Access Journals (Sweden)

    Koiprasert, H.

    2005-01-01

    Full Text Available Arc spraying as a coating method is being employed in various industrial applications as a part of maintenance service, and also as a surface engineering technique for many machine parts and components. The major cost in producing the arc spray coating is, however, based on the cost of the arc wire comsumables. This project was carried out to investigate the use of the commercially-available gas metal arc welding wire (GMAW wire as a cheaper alternative to the special-purpose arc wire comsumables. The wire material chosen for this early study is the 316L stainless steel, due to its popularity in many applications as a built-up coating for worn parts. The physical properties of the coatings produced from the two sets of 316L stainless steel wire were determined to be different in the percentage of porosity and the oxide content. The mechanical properties, including the tensile bond strength and the wear rate of the coatings produced from the two types of sprayed wire, were also different. This will, in turn, result in a slight difference in the performance of thecoatings.

  16. WiredKids: From Safety and Privacy to Literacy and Empowerment.

    Science.gov (United States)

    Wolinsky, Art

    2000-01-01

    Discussion of children's Internet access focuses on WiredKids, an organization devoted to helping to empower children to use the Internet safely and in age-appropriate ways. Topics include the Children's Online Privacy and Protection Act (COPPA); parental, school, library, and commercial organization involvement; and middle school student Internet…

  17. Simultaneous On-State Voltage and Bond-Wire Resistance Monitoring of Silicon Carbide MOSFETs

    DEFF Research Database (Denmark)

    Baker, Nick; Luo, Haoze; Iannuzzo, Francesco

    2017-01-01

    the voltage between the kelvin-source and power-source can be used to specifically monitor bond-wire degradation. Meanwhile, the drain to kelvin-source voltage can be monitored to track defects in the semiconductor die or gate driver. Through an accelerated aging test on 20 A Silicon Carbide Metal-Oxide-Semiconductor-Field-Effect...

  18. Fixation of two part fracture of radial head by pre-bend K-wire: An ...

    African Journals Online (AJOL)

    The study was aimed to see the functional status of elbow after fixation with pre bend K- wire in Mason type II Radial head fractures. We have studied eight patients (3 females and 5 males) with Mason type II isolated radial head fractures aged between 15 and 65 years (average 39 years) who underwent open reduction and ...

  19. Quantum conductance in silicon quantum wires

    CERN Document Server

    Bagraev, N T; Klyachkin, L E; Malyarenko, A M; Gehlhoff, W; Ivanov, V K; Shelykh, I A

    2002-01-01

    The results of investigations of electron and hole quantum conductance staircase in silicon quantum wires are presented. The characteristics of self-ordering quantum wells of n- and p-types, which from on the silicon (100) surface in the nonequilibrium boron diffusion process, are analyzed. The results of investigations of the quantum conductance as the function of temperature, carrier concentration and modulation degree of silicon quantum wires are given. It is found out, that the quantum conductance of the one-dimensional channels is observed, for the first time, at an elevated temperature (T >= 77 K)

  20. Numerical Simulation of Wire-Coating

    DEFF Research Database (Denmark)

    Wapperom, Peter; Hassager, Ole

    1999-01-01

    A finite element program has been used to analyze the wire-coating process of an MDPE melt. The melt is modeled by a nonisothermal Carreau model. The emphasis is on predicting an accurate temperature field. Therefore, it is necessary to include the heat conduction in the metal parts. A comparison...... is made with the results of a simulation that models the heat conduction in the metal head by means of a Biot boundary condition. The influence of the wire velocity, inlet temperature and power-law index will be examined....

  1. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery.

    Science.gov (United States)

    Oh, You Na; Ha, Keong Jun; Kim, Joon Bum; Jung, Sung-Ho; Choo, Suk Jung; Chung, Cheol Hyun; Lee, Jae Won

    2015-08-01

    Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA) was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578), major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99), minor wound complications (3.6% vs. 2.0%, p=0.279), or mediastinitis (0.8% vs. 1.0%, p=1.00). Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068). The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  2. Comparison of subtransverse process wiring and sublaminar wiring in the treatment of idiopathic thoracic scoliosis.

    Science.gov (United States)

    Akmeşe, Ramazan; Kemal Us, Ali

    2013-04-01

    A retrospective study. The objectives of this study were to show the advantages of an alternative segmental spinal instrumentation technique, termed subtransverse process wiring, and compare it with a sublaminar wiring technique in the treatment of idiopathic thoracic scoliosis. High rates of neurological complications and the need for high experience limit the use of the sublaminar wiring technique, although it is an effective segmental spinal instrumentation technique in the treatment of scoliosis. This is the first study to correlate sublaminar wiring and subtransverse process wiring techniques clinically. In a retrospective study, 64 patients with idiopathic thoracic scoliosis were chosen randomly. Nineteen patients were treated with subtransverse process wires (group A), and 45 patients were treated with sublaminar wires (group B). The mean follow-up period was 50.9 months (25 to 90 mo) in group A and 57.9 months (26 to 108 mo) in group B. The average deformity correction was 26.5 degrees (52.9%) in group A and 28.9 degrees (54.1%) in group B. The average correction loss was 2.9 degrees (17.2%) in group A and 6.4 degrees (27%) in group B. None of the patients developed neurological complications in group A. In group B, 5 (11.1%) intraoperative dural tears, 4 (8.9%) neurological deficits, and 8 (14.4%) transient dysesthesia syndromes were seen. The average operation time was 3.6 hours (3 to 4 h) in group A and 4.9 hours (3.75 to 8 h) in group B. The average replacement of blood (erythrocyte suspension) was 2.9 U (2 to 5 U) in group A and 3.1 U (2 to 6 U) in group B. Sublaminar wiring is a time-consuming technique with high risks of neurological complications, whereas subtransverse process wiring is an easy and neurologically safe method, which maintains effective deformity correction and stability of the correction.

  3. Multifilament Cable Wire versus Conventional Wire for Sternal Closure in Patients Undergoing Major Cardiac Surgery

    Directory of Open Access Journals (Sweden)

    You Na Oh

    2015-08-01

    Full Text Available Background: Stainless steel wiring remains the most popular technique for primary sternal closure. Recently, a multifilament cable wiring system (Pioneer Surgical Technology Inc., Marquette, MI, USA was introduced for sternal closure and has gained wide acceptance due to its superior resistance to tension. We aimed to compare conventional steel wiring to multifilament cable fixation for sternal closure in patients undergoing major cardiac surgery. Methods: Data were collected retrospectively on 1,354 patients who underwent sternal closure after major cardiac surgery, using either the multifilament cable wiring system or conventional steel wires between January 2009 and October 2010. The surgical outcomes of these two groups of patients were compared using propensity score matching based on 18 baseline patient characteristics. Results: Propensity score matching yielded 392 pairs of patients in the two groups whose baseline profiles showed no significant differences. No significant differences between the two groups were observed in the rates of early mortality (2.0% vs. 1.3%, p=0.578, major wound complications requiring reconstruction (1.3% vs. 1.3%, p>0.99, minor wound complications (3.6% vs. 2.0%, p=0.279, or mediastinitis (0.8% vs. 1.0%, p=1.00. Patients in the multifilament cable group had fewer sternal bleeding events than those in the conventional wire group, but this tendency was not statistically significant (4.3% vs. 7.4%, p=0.068. Conclusion: The surgical outcomes of sternal closure using multifilament cable wires were comparable to those observed when conventional steel wires were used. Therefore, the multifilament cable wiring system may be considered a viable option for sternal closure in patients undergoing major cardiac surgery.

  4. Magnetic anisotropy and anisotropic ballistic conductance of thin magnetic wires

    International Nuclear Information System (INIS)

    Sabirianov, R.

    2006-01-01

    The magnetocrystalline anisotropy of thin magnetic wires of iron and cobalt is quite different from the bulk phases. The spin moment of monatomic Fe wire may be as high as 3.4 μ B , while the orbital moment as high as 0.5 μ B . The magnetocrystalline anisotropy energy (MAE) was calculated for wires up to 0.6 nm in diameter starting from monatomic wire and adding consecutive shells for thicker wires. I observe that Fe wires exhibit the change sign with the stress applied along the wire. It means that easy axis may change from the direction along the wire to perpendicular to the wire. We find that ballistic conductance of the wire depends on the direction of the applied magnetic field, i.e. shows anisotropic ballistic magnetoresistance. This effect occurs due to the symmetry dependence of the splitting of degenerate bands in the applied field which changes the number of bands crossing the Fermi level. We find that the ballistic conductance changes with applied stress. Even for thicker wires the ballistic conductance changes by factor 2 on moderate tensile stain in our 5x4 model wire. Thus, the ballistic conductance of magnetic wires changes in the applied field due to the magnetostriction. This effect can be observed as large anisotropic BMR in the experiment

  5. Effects of coded-wire-tagging on stream-dwelling Sea Lamprey larvae

    Science.gov (United States)

    Johnson, Nicholas; Swink, William D.; Dawson, Heather A.; Jones, Michael L.

    2016-01-01

    The effects of coded wire tagging Sea Lamprey Petromyzon marinus larvae from a known-aged stream-dwelling population were assessed. Tagged larvae were significantly shorter on average than untagged larvae from 3 to 18 months after tagging. However, 30 months after tagging, the length distribution of tagged and untagged larvae did not differ and tagged Sea Lampreys were in better condition (i.e., higher condition factor) and more likely to have undergone metamorphosis than the untagged population. The reason why tagged larvae were more likely to metamorphose is not clear, but the increased likelihood of metamorphosis could have been a compensatory response to the period of slower growth after tagging. Slower growth after tagging was consistent across larval size-classes, so handling and displacement from quality habitat during the early part of the growing season was likely the cause rather than the tag burden. The tag effects observed in this study, if caused by displacement and handling, may be minimized in future studies if tagging is conducted during autumn after growth has concluded for the year.

  6. EDITORIAL More than a wire More than a wire

    Science.gov (United States)

    Demming, Anna

    2010-10-01

    Nanowires are the natural evolution of the connections in circuits when scaled down to nanometre sizes. On closer inspection, of course, the role of nanowires in developing new technologies is much more than just a current-bearing medium. By sizing the diameters of these objects down to the nanoscale, their properties become increasingly sensitive to factors such as the gas composition, temperature and incident light of their surrounding environment, as well as defects and variations in diameter. What becomes important in modern electronics innovations is not just what is connected, but how. Nanowires had already begun to attract the attention of researchers in the early 1990s as advances in imaging and measurement devices invited researchers to investigate the properties of these one-dimensional structures [1, 2]. This interest has sparked ingenious ways of fabricating nanowires such as the use of a DNA template. A collaboration of researchers at Louisiana Tech University in the US hs provided an overview of various methods to assemble conductive nanowires on a DNA template, including a summary of different approaches to stretching and positioning the templates [3]. Work in this area demonstrates a neat parallel for the role of DNA molecules as the building blocks of life and the foundations of nanoscale device architectures. Scientists at HP Labs in California are using nanowires to shrink the size of logic arrays [4]. One aspect of electronic interconnects that requires particular attention at nanoscale sizes is the effect of defects. The researchers at HP Labs demonstrate that their approach, which they name FPNI (field-programmable nanowire interconnect), is extremely tolerant of the high defect rates likely to be found in these nanoscale structures, and allows reduction in size and power without significantly sacrificing the clock rate. Another issue in scaling down electronics is the trend for an increasing resistivity with decreasing wire width. Researchers

  7. Evolution of cementite morphology in pearlitic steel wire during wet wire drawing

    DEFF Research Database (Denmark)

    Zhang, Xiaodan; Godfrey, Andrew; Hansen, Niels

    2010-01-01

    decreasing from 19 nm (ε = 0) to 2 nm (ε = 3.7) in correspondence with the reduction in wire diameter. The deformation of the cementite is strongly related to plastic deformation in the ferrite, with coarse slip steps, shear bands and cracks in the cementite plates/particles observed parallel to either {110...... microscope observations show that cementite plates become increasingly aligned with the wire axis as the drawing strain is increased. Measurements in the transmission electron microscope show that the cementite deforms plastically during wire drawing , with the average thickness of the cementite plates...

  8. Load-Deflection and Friction Properties of PEEK Wires as Alternative Orthodontic Wires

    OpenAIRE

    Tada, Yoshifumi; Hayakawa, Tohru; Nakamura, Yoshiki

    2017-01-01

    Polyetheretherketone (PEEK) is now attracting attention as an alternative to metal alloys in the dental field. In the present study, we evaluated the load-deflection characteristics of PEEK wires in addition to their frictional properties. Three types of PEEK wires are used: two sizes of rectangular shape, 0.016 ? 0.022 in2 and 0.019 ? 0.025 in2 (19-25PEEK), and rounded shape, diameter 0.016 in (16PEEK). As a control, Ni-Ti orthodontic wire, diameter 0.016 in, was used. The three-point bendin...

  9. Design of power cable grounding wire anti-theft monitoring system

    Science.gov (United States)

    An, Xisheng; Lu, Peng; Wei, Niansheng; Hong, Gang

    2018-01-01

    In order to prevent the serious consequences of the power grid failure caused by the power cable grounding wire theft, this paper presents a GPRS based power cable grounding wire anti-theft monitoring device system, which includes a camera module, a sensor module, a micro processing system module, and a data monitoring center module, a mobile terminal module. Our design utilize two kinds of methods for detecting and reporting comprehensive image, it can effectively solve the problem of power and cable grounding wire box theft problem, timely follow-up grounded cable theft events, prevent the occurrence of electric field of high voltage transmission line fault, improve the reliability of the safe operation of power grid.

  10. Cavitation and formation of foam-like structures inside exploding wires

    Science.gov (United States)

    Zhakhovsky, Vasily V.; Pikuz, Sergei A.; Tkachenko, Svetlana I.; Sasorov, Pavel V.; Shelkovenko, Tatiana A.; Knapp, Patrick F.; Saylor, Charles C.; Hammer, David A.

    2012-03-01

    Large-scale molecular dynamics (MD) simulations are used to study explosions of aluminum wires heated by electric current pulses. It is shown that the observed nonuniform radial expansion of the heated wire is associated with a liquid-vapor phase transition, which is caused by convergence of a radial tensile wave towards the center of the wire. Tension within the wave leads to cavitation in stretched melt that subsequently forms into a low-density foam-like material surrounded by a dense liquid shell. The foam decays into liquid droplets before the outer shell breaks apart. Simulated density profiles demonstrate good qualitative agreement with experimental high-resolution X-ray images showing the complex hollow structures within the long-living dense core.

  11. Vibration characteristics of Ni-Ti pseudo-elastic wire inter-weaved fabric composites

    Science.gov (United States)

    Xu, Lei; Wang, Rui; Yang, Qiuhong; Dong, Li

    2009-07-01

    This paper presents a study on the vibration characteristics of Ni-Ti wire inter-weaved glass fabric/epoxy composites. The Ni-Ti pseudo-elastic wires were used as warp yarns and embedded in the fabric preforms with various weaving methods. Dynamic Mechanical Analyzer (DMA) and vibration test technique were used to reveal the dynamical behaviors of specimens in different frequencies of vibration. The storage modulus E', the loss tanδ, the natural frequency f and damping ratio η were examined. The energy dissipation behaviors of the Ni-Ti pseudo-elastic wire, the geometry of textile fabric was also studied. The effect of weaving method on the vibration behavior in Shape Memory Alloy (SMA) based textile composites was considered. The results showed that: (I) the energy dissipation capacity of the wire could be significantly improved by increasing the tensile strain and speed, but slightly affected by loading frequency; (II) the woven of few Ni-Ti warps caused the increase of the storage modulus and the change of the loss tanδ. In the buckling vibration, the damping effects of Ni-Ti pseudo-elastic wires vary with the woven structures. The compact woven structure with proper Ni-Ti warp architectures would receive a small amplitude and good damping.

  12. STRUCTURE AND CHARACTERISTICS OF PATENTED HIGH-CARBON WIRE

    Directory of Open Access Journals (Sweden)

    A. Ju. Borisenko

    2011-01-01

    Full Text Available The influence of bainite structure on mechanical characteristics of wire of steel 80 after patenting is studied. The quantity and structure state of bainite, providing high complex of mechanical characteristics of high-carbon wire, is determined.

  13. Spectroscopic properties of colloidal indium phosphide quantum wires

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Lin-Wang; Wang, Fudong; Yu, Heng; Li, Jingbo; Hang, Qingling; Zemlyanov, Dmitry; Gibbons, Patrick C.; Wang, Lin-Wang; Janes, David B.; Buhro, William E.

    2008-07-11

    Colloidal InP quantum wires are grown by the solution-liquid-solid (SLS) method, and passivated with the traditional quantum dots surfactants 1-hexadecylamine and tri-n-octylphosphine oxide. The size dependence of the band gaps in the wires are determined from the absorption spectra, and compared to other experimental results for InP quantum dots and wires, and to the predictions of theory. The photoluminescence behavior of the wires is also investigated. Efforts to enhance photoluminescence efficiencies through photochemical etching in the presence of HF result only in photochemical thinning or photo-oxidation, without a significant influence on quantum-wire photoluminescence. However, photo-oxidation produces residual dot and rod domains within the wires, which are luminescent. The results establish that the quantum-wire band gaps are weakly influenced by the nature of the surface passivation, and that colloidal quantum wires have intrinsically low photoluminescence efficiencies.

  14. Lower incisor intrusion with intraoral transosseous stainless steel wire anchorage in rabbits.

    Science.gov (United States)

    Wu, Jian-chao; Huang, Ji-na; Lin, Xin-ping

    2010-06-01

    The purpose of this research was to investigate the potential use of intraoral transosseous stainless steel wires as anchorage for intrusion of the lower incisors using a rabbit model. Placement of intraoral transosseous stainless steel wires around incisors is similar to that of intraoral transosseous wiring of edentulous mandibular fractures. Ten male New Zealand rabbits, 9 +/- 1.5 months of age, average weight 1.8 +/- 0.3 kg, were used in this study. One lower incisor was intruded with a 50 g bilateral force using a coil spring for 10 weeks, while the other incisor served as the control. Clinical measurements of the distances between the occlusal edges of the incisors (EE) were performed weekly with a calliper. In addition to standard descriptive statistical calculations, a paired Student's t-test was used for comparison of the two groups. All surgical sites healed uneventfully after insertion of the wires. Significant differences were found in the change of EE between the experimental and control sides from 4 weeks onwards. Intrusion of the incisor, 4 +/- 0.58 mm, was seen on the test side, while EE on the control side remained unchanged. Within the limits of this animal study, it is concluded that the intraoral transosseous stainless steel wire anchorage system is a cost-effective method for intrusion of lower incisors when the use of other anchorage system is not possible.

  15. The Effect of Wire Dimension, Type and Thickness of Coating Layer on Friction of Coated Stainless-Steel Arch Wires

    Directory of Open Access Journals (Sweden)

    Ahmed Abdulhussain Abbas

    2018-03-01

    Full Text Available Background/Purpose: Esthetic coated arch wires are the desired types to match esthetic brackets in the clinical orthodontics, but the presence of coating layer is greatly affect friction during sliding mechanics. The aims of this study were to evaluate the effect of total wire dimension with the type and thickness of coating layer on friction of coated stainless-steel wires. Methods: The sample of this study consisted of 140 segments of coated stainless-steel arch wires involving two wire dimensions (0.016 × 0.022 inch and 0.019 × 0.025 inch. The samples were supplied from seven companies (DB, RMO, TP, DANY, G&H, Highland and Hubit and the uncoated control samples were supplied from IOS company. Wire dimensions and thickness of coating layer were measured by the metallurgical light incident microscope and the static frictional force was measured using pulling the wire through set of ceramic brackets by the universal testing machine. The data were then statistically analyzed using ANOVA tests. Results: Generally measured wire dimensions do not match the stated dimensions by the manufacturer. The frictional forces of coated wires differ from uncoated control being higher in the labially coated wires and lesser in the fully Teflon coated wires owing to differences in the wire dimension, thickness of coating layer, and physical properties of coating materials. Conclusion: when tested in vitro, Teflon fully coated wires produce the least amount of friction.

  16. Release of nickel and chromium ions from orthodontic wires following the use of teeth whitening mouthwashes

    Directory of Open Access Journals (Sweden)

    AmirHossein Mirhashemi

    2018-02-01

    Full Text Available Abstract Background Corrosion resistance is an important requirement for orthodontic appliances. Nickel and chromium may be released from orthodontic wires and can cause allergic reactions and cytotoxicity when patients use various mouthwashes to whiten their teeth. Our study aimed to assess the release of nickel and chromium ions from nickel titanium (NiTi and stainless steel (SS orthodontic wires following the use of four common mouthwashes available on the market. Methods This in vitro, experimental study was conducted on 120 orthodontic appliances for one maxillary quadrant including five brackets, one band and half of the required length of SS, and NiTi wires. The samples were immersed in Oral B, Oral B 3D White Luxe, Listerine, and Listerine Advance White for 1, 6, 24, and 168 h. The samples immersed in distilled water served as the control group. Atomic absorption spectroscopy served to quantify the amount of released ions. Results Nickel ions were released from both wires at all time-points; the highest amount was in Listerine and the lowest in Oral B mouthwashes. The remaining two solutions were in-between this range. The process of release of chromium from the SS wire was the same as that of nickel. However, the release trend in NiTi wires was not uniform. Conclusions Listerine caused the highest release of ions. Listerine Advance White, Oral B 3D White Luxe, and distilled water were the same in terms of ion release. Oral B showed the lowest amount of ion release.

  17. Bandwidth improvement for germanium photodetector using wire bonding technology.

    Science.gov (United States)

    Chen, Guanyu; Yu, Yu; Deng, Shupeng; Liu, Lei; Zhang, Xinliang

    2015-10-05

    We demonstrate an ultrahigh speed germanium photodetector by introducing gold wires into the discrete ground electrodes with standard wire bonding technology. To engineer the parasitic parameter, the physical dimension of the gold wire used for wire bonding is specially designed with an inductance of about 450 pH. Simulation and experimental results show that the bandwidth of the photodetector can be effectively extended from less than 30 GHz to over 60 GHz.

  18. Signals analysis of fluxgate array for wire rope defaults

    International Nuclear Information System (INIS)

    Gu Wei; Chu Jianxin

    2005-01-01

    In order to detecting the magnetic leakage fields of the wire rope defaults, a transducer made up of the fluxgate array is designed, and a series of the characteristic values of wire rope defaults signals are defined. By processing the characteristic signals, the LF or LMA of wire rope are distinguished, and the default extent is estimated. The experiment results of the new method for detecting the wire rope faults are introduced

  19. MDT WIRE TENSION MEASUREMENT USING AN ELECTROSTATIC METHOD

    CERN Document Server

    Balla, A; Esposito, B; Felici, G; Nedosekin, A; Ponzio, B; Russo, V; Spitalieri, M C

    1998-01-01

    An automated system to measure wire tension in MDT tubes is presented.The method uses electrostatic forces between wire and tube to excite mechanical oscillation around the wire harmonic resonance. A LC oscillating circuit is used to measure capacitance variation due towire oscillation. Wire tension is determined by the frequency at which the wirereaches the maximum oscillation amplitude. Both the excitation and measuring circuits are controlled by a computer.

  20. Electricity: Residential Wiring. Secondary Schools. Curriculum Guide.

    Science.gov (United States)

    Trust Territory of the Pacific Islands Dept. of Education, Saipan.

    This curriculum guide on residential wiring for secondary students is one of six developed for inservice teachers at Marianas High School in Saipan. The guide provides the rationale, description, goals, and objectives of the program; the program of studies and performance objectives by levels; samples of lesson plans for effective delivery of…

  1. Building Trades. Carpentry, Electrical Wiring, Plumbing.

    Science.gov (United States)

    Missouri Univ., Columbia. Instructional Materials Lab.

    This curriculum guide contains 21 units of self-paced, self-contained instructional materials in the complete building trades curriculum. It is divided into vocational areas of carpentry, electrical wiring, and plumbing. The purpose of the curriculum is to provide minimum skills for disadvantaged and handicapped students entering mainstream…

  2. Description of CBETA magnet tuning wire holders

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, S. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2017-07-19

    A non-­magnetic insert will be placed directly inside the permanent magnet blocks in every CBETA Halbach magnet in order to hold a set of iron “tuning wires”. These wires have various lengths around the perimeter of the aperture in order to cancel multipole field errors from the permanent magnet blocks.

  3. Selective deposition by hot wire ALD

    NARCIS (Netherlands)

    Kovalgin, Alexey Y.; Yang, Mengdi; Aarnink, Antonius A.I.; Wolters, Robertus A.M.

    2018-01-01

    A method for selectively depositing a metal nlm onto a substrate is disclosed. In particular, the method comprising nowing a metal precursor onto the substrate and nowing a non-metal precursor onto the substrate,while contacting the non-metal precursor with a hot wire. Specincally, a reaction

  4. Studying superconducting Nb$_{3}$Sn wire

    CERN Multimedia

    AUTHOR|(CDS)2099575

    2015-01-01

    Studying superconducting Nb$_{3}$Sn wire. From the current experience from LHC and HL-LHC we know that the performance requirements for Nb$_{3}$Sn conductor for future circular collider are challenging and should exceed that of present state-of-the-art materials.

  5. Studying superconducting Nb3Sn wire

    CERN Multimedia

    AUTHOR|(CDS)2099575

    2015-01-01

    Studying superconducting Nb3Sn wire. From the current experience from LHC and HL-LHC we know that the performance requirements for Nb3Sn conductor for future circular collider are challenging and should exceed that of present state-of-the-art materials.

  6. Niobium Titanium and Copper wire samples

    CERN Multimedia

    2009-01-01

    Two wire samples, both for carrying 13'000Amperes. I sample is copper. The other is the Niobium Titanium wiring used in the LHC magnets. The high magnetic fields needed for guiding particles around the Large Hadron Collider (LHC) ring are created by passing 12’500 amps of current through coils of superconducting wiring. At very low temperatures, superconductors have no electrical resistance and therefore no power loss. The LHC is the largest superconducting installation ever built. The magnetic field must also be extremely uniform. This means the current flowing in the coils has to be very precisely controlled. Indeed, nowhere before has such precision been achieved at such high currents. Magnet coils are made of copper-clad niobium–titanium cables — each wire in the cable consists of 9’000 niobium–titanium filaments ten times finer than a hair. The cables carry up to 12’500 amps and must withstand enormous electromagnetic forces. At full field, the force on one metre of magnet is comparable ...

  7. Two-wire Interface for Digital Microphones

    NARCIS (Netherlands)

    Groothedde, Wouter; Klumperink, Eric A.M.; Nauta, Bram; Eschauzier, Rudolphe Gustave Hubertus; van Rijn, Nico

    2003-01-01

    A two-wire interface for a digital microphone circuit includes a power line and a ground line. The interface utilizes the ground line as a "voltage active line" to transmit both clock and data signals between the digital microphone circuit and a receiving circuit. The digital microphone circuit

  8. Two-Wire interface for digital microphones

    NARCIS (Netherlands)

    Groothedde, Wouter; Klumperink, Eric A.M.; Nauta, Bram; Eschauzier, Rudolphe Gustave Hubertus; van Rijn, Nico

    2005-01-01

    A two-wire interface for a digital microphone circuit includes a power line and a ground line. The interface utilizes the ground line as a "voltage active line" to transmit both clock and data signals between the digital microphone circuit and a receiving circuit. The digital microphone circuit

  9. Functional and structural causes of forests productivity decay with age: experimental analysis of a chrono-sequence of maritime pine stands; Causes fonctionnelles et structurales du declin de productivite des forets avec l'age: analyse experimentale d'une chronosequence de peuplements de pin maritime

    Energy Technology Data Exchange (ETDEWEB)

    Delzon, S.

    2004-06-15

    The aim of this work was to understand the causes of forest growth decline with increasing age. We investigated changes in several eco-physiological parameters in a chrono-sequence of four even-aged maritime pine stands. Above-ground productivity declined by a factor of 2.5 from the youngest to the oldest stands. This decline was explained by a decrease of gross primary production, due to a decline in both stand leaf area and foliar productivity. Our measurements clearly showed a decrease in leaf-specific hydraulic conductance with increasing tree height (50% lower in 30 m trees than in 10 m trees). We also found that needle water potential was maintained above a minimum threshold value of -2.0 MPa independently of tree age and height. This hydraulic homeostasis occurred through a decline in leaf / sapwood area ratio (hydraulic compensation) and a decline in stomatal conductance (physiological compensation). Both the increased investment in non-productive versus productive tissues and stomatal closure may have contributed to the observed decrease in foliar productivity with increasing tree height. Consequently, over-storey transpiration was reduced by a factor of three between the 10-yr and the 91-yr old stands. Nevertheless, our findings suggest that the total ecosystem evaporation remains constant in ageing forests due to an increase in under-storey transpiration, which may counterbalance the decrease in tree transpiration. Photosynthetic capacity also decreased in older stands, mainly through a decline in phosphorus concentration. Our results support the hypothesis that the age-related decline in forest growth is associated with decreased availability of the most limiting resource, this being phosphorus for the maritime Pine chrono-sequence investigated. (author)

  10. Infección por Chlamydia trachomatis en mujeres cubanas en edad reproductiva Infection caused by Chlamydia trachomatis in Cuban women at reproductive age

    Directory of Open Access Journals (Sweden)

    Maydelín Frontela Noda

    2006-08-01

    Full Text Available El presente trabajo tuvo como objetivo determinar la frecuencia y los factores asociados a la infección por Chlamydia trachomatis en mujeres cubanas en edad reproductiva. Se realizó un estudio transversal en mujeres que asistieron a consultas de ginecología, infertilidad y terminación del embarazo en Ciudad de La Habana. Se obtuvieron muestras de exudado endocervical de 224 mujeres, mediante la técnica de la reacción en cadena de la polimerasa. Adicionalmente se aplicó un cuestionario sobre algunos aspectos sociodemográficos, clínicos y de conducta sexual. Los datos se analizaron con el uso de los métodos de Chi cuadrado y razón de ventajas. La frecuencia total de la infección fue de 6,9. Hubo 6 asociaciones significativas: edad menor de 25 años (14,5, que fuera soltera (13,4; no refiriera síntomas de infección ginecológica (14,0; no tuviera antecedentes de enfermedad inflamatoria pélvica (10,1 ni de infecciones de transmisión sexual (12,3 y que hubiera tenido más de una pareja sexual en los últimos 3 meses. Se concluye que estos resultados demuestran que la infección se presenta con mayor frecuencia en las mujeres adolescentes y adultas jóvenes, solteras, asintomáticas y con conductas sexuales de riesgo.The aim of this article was to determine the frequency and factors associated with the infection caused by Chlamydia trachomatis at reproductive age. A cross-sectional study was conducted among women that visited the offices of gynecology, infertility and full pregnancy, in Havana City. Endocervical smear samples from 224 women were obtained and processed by polymerase chain reaction. A questionnaire was applied on some sociodemographic, clinical and sexual behavior aspects. Data were analyzed by the Chi square test and odds ratio. The total frequency of infection was 6.9. Six significant associations were found: age under 25 (14.5, being single (13.4, referring no symptoms of gynecological infection (14.0, having no

  11. Does long-term intraoral service affect the mechanical properties and elemental composition of multistranded wires of lingual fixed retainers?

    Science.gov (United States)

    Zinelis, Spiros; Pandis, Nikolaos; Al Jabbari, Youssef S; Eliades, George; Eliades, Theodore

    2017-06-15

    The aim of this study was to evaluate the elemental and mechanical alterations of stainless steel (SS) multistranded orthodontic wires used in fixed retention after intraoral ageing. Two types of 0.022-inch, seven-stranded wires, Lingual Retainer Wire (LRW) and Tru-Chrome (TCH), from the same manufacturer (Rocky Mountain Orthodontics, Denver, Colo, USA) were tested. Thirty-three samples from LRW group and thirty-seven from TCH were collected, whereas three unused wires from each package were used as controls. The median ageing time for LRW was 7.4 years and 8.4 for TCH. All samples were subjected to scanning electron microscope/X-ray energy dispersive spectroscopy analysis. Three spectra were taken from the surface of each wire and then all samples were used for the assessment of Martens hardness, indentation modulus (EIT), and elastic index (ηIT) with the instrumented indentation testing method (IIT). The intraoral ageing time was statistically compared between the two groups by Mann-Whitney rank sum test and the compositional and mechanical properties were compared by unpaired t-test. The Spearman correlation between elemental content and ageing time was carried out for all elements (a = 0.05). No significant differences were found for both the elemental content and for the mechanical properties between the wires tested. Spearman analysis revealed no correlation between elemental content and intraoral time while two groups share statistically equal intraoral ageing times (P > 0.05). Both wires seemed to maintain their mechanical and elemental integrity within a period of 14-year intraoral exposure, whereas no measurable ionic release could be identified. © The Author 2017. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions, please email: journals.permissions@oup.com

  12. Structured Wiring Systems: Bringing Sanity to Network Cabling!

    Science.gov (United States)

    Learn, Larry L., Ed.

    1995-01-01

    While most organizations, including libraries, can benefit from a structured wiring system, few likely have the expertise and resources to place, specify, and install network cabling by themselves. This article reviews common wiring plans, addresses basic concepts of structured wiring systems, and discusses the importance and benefits of such a…

  13. Modeling, simulation and parametric optimization of wire EDM ...

    African Journals Online (AJOL)

    In the present work, quadratic mathematical models have been derived to represent the process behavior of wire electrical discharge machining (WEDM) operation. Experiments have been conducted with six process parameters: discharge current, pulse duration, pulse frequency, wire speed, wire tension and dielectric flow ...

  14. Bonding of a niobium wire to a niobium thin film

    NARCIS (Netherlands)

    Jaszczuk, W.; Jaszczuk, W.; ter Brake, Hermanus J.M.; Flokstra, Jakob; Veldhuis, Dick; Stammis, R.; Rogalla, Horst

    1991-01-01

    A method for bonding a niobium wire to a niobium thin film is described. The bonds are to be used as superconducting connections between wire-wound gradiometers and thin-film coupling coils on DC SQUIDS. The method is characterized by two steps. Firstly, the hardness of the niobium wire is reduced

  15. 77 FR 28404 - Galvanized Steel Wire From China and Mexico

    Science.gov (United States)

    2012-05-14

    ...)] Galvanized Steel Wire From China and Mexico Determinations On the basis of the record \\1\\ developed in the... reason of imports from Mexico of galvanized steel wire, provided for in subheadings 7217.20.30, 7217.20... galvanized steel wire from China and Mexico were sold at LTFV within the meaning of 733(b) of the Act (19 U.S...

  16. 76 FR 29266 - Galvanized Steel Wire From China and Mexico

    Science.gov (United States)

    2011-05-20

    ...)] Galvanized Steel Wire From China and Mexico Determinations On the basis of the record \\1\\ developed in the... reason of imports from China and Mexico of galvanized steel wire, provided for in subheading 7217.20.30... subsidized imports of galvanized steel wire from China and Mexico. Accordingly, effective March 31, 2011, the...

  17. 46 CFR 111.30-19 - Buses and wiring.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Buses and wiring. 111.30-19 Section 111.30-19 Shipping... REQUIREMENTS Switchboards § 111.30-19 Buses and wiring. (a) General. Each bus must meet the requirements of... 60092-302 (clause 7) (incorporated by reference; see 46 CFR 110.10-1). (b) Wiring. Instrumentation and...

  18. Basic Wiring. Third Edition. Teacher Edition [and] Student Edition.

    Science.gov (United States)

    Kaltwasser, Stan; Flowers, Gary; Blasingame, Don; Batson, Larry; Ipock, Dan; Carroll, Charles; Friesen, Wade; Fleming, Glenn

    This publication contains both a teacher edition and a student edition of materials for a foundation course in an electrical wiring program. The course introduces basic concepts and skills that are prerequisites to residential wiring and commercial and industrial wiring courses. The contents of the materials are tied to measurable and observable…

  19. 29 CFR 1926.404 - Wiring design and protection.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 8 2010-07-01 2010-07-01 false Wiring design and protection. 1926.404 Section 1926.404... Requirements § 1926.404 Wiring design and protection. (a) Use and identification of grounded and grounding... construction sites, which are not a part of the permanent wiring of the building or structure and which are in...

  20. 46 CFR 129.340 - Cable and wiring.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cable and wiring. 129.340 Section 129.340 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS ELECTRICAL INSTALLATIONS Power Sources and Distribution Systems § 129.340 Cable and wiring. (a) If individual wires, rather than...