WorldWideScience

Sample records for wingate anaerobic test

  1. Comparison of the Wingate and Bosco anaerobic tests.

    Science.gov (United States)

    Sands, William A; McNeal, Jeni R; Ochi, Marshall T; Urbanek, Terri L; Jemni, Monem; Stone, Michael H

    2004-11-01

    The purpose of this study was to compare the Wingate cycling and Bosco repeated jumps anaerobic tests. Eleven men (21.36 +/- 1.6 years; 179.1 +/- 9.3 cm; 78.7 +/- 11.0 kg) and 9 women (21.89 +/- 3.66 years; 171.8 +/- 10.0 cm; 75.9 +/- 21.4 kg), all university athletes, volunteered to participate. Subjects performed each test in random order. The tests consisted of a 30-second Wingate test and a 60-second Bosco test. The Wingate test was conducted using a Monark cycle ergometer and the Bosco test was conducted on a force platform. Following the performance of each test, peak lactate concentrations were determined. Average and peak power values were statistically greater in men and on the Bosco test. Peak lactate values were statistically greater in men but did not differ based on test. Correlations between peak lactate concentrations between tests and lactate values with peak or average power were not statistically significant. The relationship between peak power between tests was statistically significant among men, but not women. The results of the study indicated that the Bosco and Wingate tests, which both measure anaerobic characteristics, appear to measure different aspects of anaerobic power and capacity. The Bosco test also may be inappropriate for athletes who are not well trained in jumping.

  2. Allometric Scaling of Wingate Anaerobic Power Test Scores in Women

    Science.gov (United States)

    Hetzler, Ronald K.; Stickley, Christopher D.; Kimura, Iris F.

    2011-01-01

    In this study, we developed allometric exponents for scaling Wingate anaerobic test (WAnT) power data that are reflective in controlling for body mass (BM) and lean body mass (LBM) and established a normative WAnT data set for college-age women. One hundred women completed a standard WAnT. Allometric exponents and percentile ranks for peak (PP)…

  3. Influence of music on Wingate Anaerobic Test performance.

    Science.gov (United States)

    Pujol, T J; Langenfeld, M E

    1999-02-01

    While several studies have investigated the effects of music on cardiovascular endurance performance and perceived exertion during exercise of moderate intensity, few studies have investigated such effects on supramaximal exercise bouts. The purpose of the present study was to assess whether music affects performance on the Wingate Anaerobic Test. Each of the 12 men and 3 women were required to report to the laboratory on two occasions, once for tests in the music condition and once for tests in the nonmusic condition. Conditions were randomly ordered. All music selections were set at the same tempo. On each test day subjects performed a series of three Wingate Anaerobic Tests with 30-sec. rests in between. On Test 3 subjects were asked to continue pedaling until fatigued. Mean Power Output, Maximum Power Output, Minimum Power Output, and Fatigue Index were compared between conditions for each test using a repeated-measures analysis of variance. Time to fatigue on Trial 3 compared by analysis of variance gave no significant differences between conditions for any measures.

  4. Enhancement on Wingate Anaerobic Test Performance With Hyperventilation.

    Science.gov (United States)

    Leithäuser, Renate M; Böning, Dieter; Hütler, Matthias; Beneke, Ralph

    2016-07-01

    Relatively long-lasting metabolic alkalizing procedures such as bicarbonate ingestion have potential for improving performance in long-sprint to middle-distance events. Within a few minutes, hyperventilation can induce respiratory alkalosis. However, corresponding performance effects are missing or equivocal at best. To test a potential performance-enhancing effect of respiratory alkalosis in a 30-s Wingate Anaerobic Test (WAnT). 10 men (mean ± SD age 26.6 ± 4.9 y, height 184.4 ± 6.1 cm, body-mass test 1 80.7 ± 7.7 kg, body-mass test 2 80.4 ± 7.2 kg, peak oxygen uptake 3.95 ± 0.43 L/min) performed 2 WAnTs, 1 with and 1 without a standardized 15-min hyperventilation program pre-WAnT in randomized order separated by 1 wk. Compared with the control condition, hyperventilation reduced (all P Hyperventilation-induced respiratory alkalosis can enhance WAnT cycling sprint performance well in the magnitude of what is seen after successful bicarbonate ingestion.

  5. Analysis of anaerobic capacity in rowers using Wingate test on cycle and rowing ergometer.

    Science.gov (United States)

    Klasnja, Aleksandar; Barak, Otto; Popadić-Gaćesa, Jelena; Drapsin, Miodrag; Knezević, Aleksandar; Grujić, Nikola

    2010-01-01

    The 30-s all-out Wingate test has been used in athletes of all sport specialties to measure the capacity for short duration, high power output while cycling. The aim of this study was to establish differences in measuring anaerobic capacity between the classic Wingate test on a cycling ergometer and the modified Wingate test on a rowing ergometer in rowers. A group of20 rowers was tested by both the cycle and rowing ergometers during 30s of maximum power to test anaerobic capacity and to make correlation between these tests. The parameters measured were the peak power and mean power. The peak power on the cycling ergometer was 475 +/- 75.1W and 522.4 +/- 81W (p rowing ergometer. The mean power on the cycling ergometer and the rowing ergometer was 344.4 +/- 51.1W and 473.7W +/- 67.2, (p rowing ergometer. By correlating the anaerobic parameters of the classic Wingate test and a modified Wingate test on the rowing ergometer a significant positive correlation was detected in the peak power (r = 0.63, p rowing ergometer compared to the cycling ergometer due to a better mechanical efficiency. It is concluded that the modified Wingate test on the rowing ergometer can be used in rowers for testing their anaerobic capacity as a sport specific test ergometer since it provides more precise results.

  6. Validity of the RAST for evaluating anaerobic power performance as compared to Wingate test in cycling athletes

    OpenAIRE

    Queiroga,Marcos Roberto; Cavazzotto,Timothy Gustavo; Katayama,Keyla Yukari; Portela,Bruno Sérgio; Tartaruga,Marcus Peikriszwili; Ferreira,Sandra Aires

    2013-01-01

    The validity of the Running-based Anaerobic Sprint Test (RAST) was investigated to evaluate the anaerobic power performance in comparison to Wingate test in cycling athletes. Ten mountain-bike male cyclists (28.0±7.3 years) randomly performed Wingate Test and RAST with two trials each. After several anthropometric measurements, peak power (PP), mean power (MP) and fatigue index (FI) for RAST and Wingate Test were analyzed using Student's paired t-test, Pearson's linear correlation test (r) an...

  7. Validity of the RAST for evaluating anaerobic power performance as compared to Wingate test in cycling athletes

    Directory of Open Access Journals (Sweden)

    Marcos Roberto Queiroga

    2013-12-01

    Full Text Available The validity of the Running-based Anaerobic Sprint Test (RAST was investigated to evaluate the anaerobic power performance in comparison to Wingate test in cycling athletes. Ten mountain-bike male cyclists (28.0±7.3 years randomly performed Wingate Test and RAST with two trials each. After several anthropometric measurements, peak power (PP, mean power (MP and fatigue index (FI for RAST and Wingate Test were analyzed using Student's paired t-test, Pearson's linear correlation test (r and Bland and Altman's plots. Results showed that, with the exception of FI (33.8±4.6% vs. 37.8±7.9%; r=0.172, significant differences were detected between the Wingate and RAST tests with regard to PP and MP. Although there was a strong correlation for PP and MP, or rather, 0.831 and 0.714 respectively, agreement of analysis between Wingate and RAST protocols was low. The above suggested that RAST was not appropriate to evaluate the performance of anaerobic power by Wingate test in cycling athletes.

  8. Performance during the Wingate anaerobic test and muscle morphology in males and females.

    Science.gov (United States)

    Froese, E A; Houston, M E

    1987-02-01

    Performance indices during the Wingate 30-s anaerobic test and their relationship to muscle morphology of the vastus lateralis muscle were studied in 30 untrained male and female subjects. Absolute values for peak power (P05), total work performed (TW), power decrease (PD), and post-test blood lactate concentration were significantly greater for the male subjects. When expressed per unit of body mass or leg volume, both P05 and TW were larger for the males than the females (P less than 0.05). Significant correlations were noted for P05, TW, PD, and blood lactate and the percent of fast-twitch (FT) fibers and the percent relative area of FT fibers for the male but not the female subjects. The results from this experiment reveal a significant influence of muscle morphology on short-term anaerobic work performance for these male subjects. The absence of a similar relationship for the women subjects was likely due to the use of an inappropriately high resistance setting.

  9. Comparison between Standing Broad Jump test and Wingate test for assessing lower limb anaerobic power in elite sportsmen.

    Science.gov (United States)

    Krishnan, Anup; Sharma, Deep; Bhatt, Madhu; Dixit, Apoorv; Pradeep, P

    2017-04-01

    Lower limb explosive power is an important motor quality for sporting performance and indicates use of anaerobic energy systems like stored ATP and Creatine phosphate system. Weightlifting, Fencing and Wrestling use it for monitoring and identification of potential sportsmen. The Wingate test and Standing Broad Jump (SBJ) test are reliable and accurate tests for its assessment. This study conducted on elite Indian sportsmen tries to analyse feasibility of use of the SBJ test in sports and military medicine when Wingate test is impractical. 95 elite sportsmen (51 Fencers, 17 Weight lifters and 27 Wrestlers) of a sports institute were administered Wingate cycle ergometer test and SBJ under standardised conditions. The results were analysed for mass and inter-discipline correlation. Analysis using Pearson's correlation showed significant positive correlation between Peak power (r = 0.446, p Weightlifters. Bland-Altman plot analysis showed that about 94% pairs of peak power and SBJ were within limits of agreement for each discipline as well as among all sportsmen. The test results show definite correlation and SBJ test can be used as a field test in performance monitoring, talent identification, military recruit screening and injury prevention.

  10. Vertical Jumping Tests versus Wingate Anaerobic Test in Female Volleyball Players: The Role of Age

    Directory of Open Access Journals (Sweden)

    Pantelis Theodoros Nikolaidis

    2016-02-01

    Full Text Available Single and continuous vertical jumping tests, as well as the Wingate anaerobic test (WAnT, are commonly used to assess the short-term muscle power of female volleyball players; however, the relationship among these tests has not been studied adequately. Thus, the aim of the present study was to examine the relationship of single and continuous vertical jumps with the WAnT in female volleyball players. Seventy adolescent (age 16.0 ± 1.0 years, body mass 62.5 ± 7.1 kg, height 170.4 ± 6.1 cm, body fat 24.2% ± 4.3% and 108 adult female volleyball players (age 24.8 ± 5.2 years, body mass 66.5 ± 8.7 kg, height 173.2 ± 7.4 cm, body fat 22.0% ± 5.1% performed the squat jump (SJ, countermovement jump (CMJ, Abalakov jump (AJ, 30 s Bosco test and WAnT (peak power, Ppeak; mean power, Pmean. Mean power in the Bosco test was correlated (low to large magnitude with Pmean of the WAnT (r = 0.27, p = 0.030 in adolescents versus r = 0.56, p < 0.001 in adults. SJ, CMJ and AJ also correlated with Ppeak (0.28 ≤ r ≤ 0.46 in adolescents versus 0.58 ≤ r ≤ 0.61 in adults and with Pmean (0.43 ≤ r ≤ 0.51 versus 0.67 ≤ r ≤ 0.71, respectively of the WAnT (p < 0.05. In summary, the impact of the Bosco test and WAnT on muscle power varied, especially in the younger age group. Single jumping tests had larger correlations with WAnT in adults than in adolescent volleyball players. These findings should be taken into account by volleyball coaches and fitness trainers during the assessment of short-term muscle power of their athletes.

  11. A WINGATE TEST

    Directory of Open Access Journals (Sweden)

    TP Souza-Junior

    2014-10-01

    Full Text Available Reactive oxygen species are produced during anaerobic exercise mostly by Fe ions released into plasma and endothelial/muscle xanthine oxidase activation that generates uric acid (UA as the endpoint metabolite. Paradoxically, UA is considered a major antioxidant by virtue of being able to chelate pro-oxidative iron ions. This work aimed to evaluate the relationship between UA and plasma markers of oxidative stress following the exhaustive Wingate test. Plasma samples of 17 male undergraduate students were collected before, 5 and 60 min after maximal anaerobic effort for the measurement of total iron, haem iron, UA, ferric-reducing antioxidant activity in plasma (FRAP, and malondialdehyde (MDA, biomarker of lipoperoxidation. Iron and FRAP showed similar kinetics in plasma, demonstrating an adequate pro-/antioxidant balance immediately after exercise and during the recovery period (5–60 min. Slight variations of haem iron concentrations did not support a relevant contribution of rhabdomyolysis or haemolysis for iron overload following exercise. UA concentration did not vary immediately after exercise but rather increased 29% during the recovery period. Unaltered MDA levels were concomitantly measured. We propose that delayed UA accumulation in plasma is an auxiliary antioxidant response to post-exercise (iron-mediated oxidative stress, and the high correlation between total UA and FRAP in plasma (R-Square = 0.636; p = 0.00582 supports this hypothesis.

  12. IGF-I AND FGF-2 RESPONSES TO WINGATE ANAEROBIC TEST IN OLDER MEN

    Directory of Open Access Journals (Sweden)

    Ruthie Amir

    2007-06-01

    Full Text Available Reduced activity of the potent anabolic effectors: insulin-like growth factor-I (IGF-I and fibroblast growth factor-2 (FGF-2, play a role in aging associated muscle loss. The effect of fitness level on IGF-I and FGF-2 responses to all-out anaerobic exercise in older men was studied. Twenty four healthy older males: 12 higher fit (58 ± 1y and 12 lower fit (59 ± 1y underwent the Wingate anaerobic test. Serum levels of IGF-I and FGF-2 were measured before, immediately after exercise, and 50 min into recovery. Immediately post exercise, the average peak power output and serum lactate were higher (p < 0.05 in the higher fit (446.0 ± 14. 9 kgm·min-1 for mean (± SD peak power and 12.6 ± 1.1 mml·l-1 for lactate compared with the lower fit individuals (284.0 ± 6.5 kgm·min-1 and 8.5 ± 0.7 mml·l-1, respectively. Pre-exercise IGF-I was lower and FGF-2 was higher in the higher fit (335.0 ± 54.0 ng·ml-1 and 1.6 ± 0.1 ng·ml-1, respectively compared with lower fit individuals (402.0 ± 50.0 ng·ml-1 and 1.4 ± 0.2 ng·ml-1, respectively. Following the anaerobic exercise, in both groups, FGF-2 decreased dramatically (p < 0.05; in the higher fit individuals FGF-2 level was 0.4 ± 0.1 pg·ml-1 compared to 0.1 ± 0.02 pg·ml-1 in the lower fit individuals. In contrast to FGF-2, IGF-I increased transiently to levels of 405.0 ± 62.0 ng·ml-1 in the higher fit individuals and to levels of 436 ± 57.0 ng·ml-1 in the lower fit individuals. However, the IGF-I elevation was significant (p < 0. 05 only in the higher fit individuals. In conclusion, the present study demonstrates that during aging, fitness level can alter circulating levels of IGF-I and FGF-2. Furthermore, fitness level can affect the response of both mediators to all-out anaerobic exercise.

  13. Effect of voluntary hypocapnic hyperventilation on the metabolic response during Wingate anaerobic test.

    Science.gov (United States)

    Fujii, Naoto; Tsuchiya, Sho-Ichiro; Tsuji, Bun; Watanabe, Kazuhito; Sasaki, Yosuke; Nishiyasu, Takeshi

    2015-09-01

    We evaluated whether hypocapnia achieved through voluntary hyperventilation diminishes the increases in oxygen uptake elicited by short-term (e.g., ~30 s) all-out exercise without affecting exercise performance. Nine subjects performed 30-s Wingate anaerobic tests (WAnT) in control and hypocapnia trials on separate days in a counterbalanced manner. During the 20-min rest prior to the 30-s WAnT, the subjects in the hypocapnia trial performed voluntary hyperventilation (minute ventilation = 31 L min(-1)), while the subjects in the control trial continued breathing spontaneously (minute ventilation = 14 L min(-1)). The hyperventilation in the hypocapnia trial reduced end-tidal CO2 pressure from 34.8 ± 2.5 mmHg at baseline rest to 19.3 ± 1.0 mmHg immediately before the 30-s WAnT. In the control trial, end-tidal CO2 pressure at baseline rest (35.9 ± 2.5 mmHg) did not differ from that measured immediately before the 30-s WAnT (35.9 ± 3.3 mmHg). Oxygen uptake during the 30-s WAnT was lower in the hypocapnia than the control trial (1.55 ± 0.52 vs. 1.95 ± 0.44 L min(-1)), while the postexercise peak blood lactate concentration was higher in the hypocapnia than control trial (10.4 ± 1.9 vs. 9.6 ± 1.9 mmol L(-1)). In contrast, there was no difference in the 5-s peak (842 ± 111 vs. 850 ± 107 W) or mean (626 ± 74 vs. 639 ± 80 W) power achieved during the 30-s WAnT between the control and hypocapnia trials. These results suggest that during short-period all-out exercise (e.g., 30-s WAnT), hypocapnia induced by voluntary hyperventilation reduces the aerobic metabolic rate without affecting exercise performance. This implies a compensatory elevation in the anaerobic metabolic rate.

  14. PPARA intron polymorphism associated with power performance in 30-s anaerobic Wingate Test.

    Directory of Open Access Journals (Sweden)

    Miroslav Petr

    Full Text Available To date, polymorphisms in several genes have been associated with a strength/power performance including alpha 3 actinin, ciliary neurotrophic factor, vitamin D receptor, or angiotensin I converting enzyme, underlining the importance of genetic component of the multifactorial strength/power-related phenotypes. The single nucleotide variation in peroxisome proliferator-activated receptor alpha gene (PPARA intron 7 G/C (rs4253778; g.46630634G>C has been repeatedly found to play a significant role in response to different types of physical activity. We investigated the effect of PPARA intron 7 G/C polymorphism specifically on anaerobic power output in a group of 77 elite male Czech ice hockey players (18-36 y. We determined the relative peak power per body weight (Pmax.kg(-1 and relative peak power per fat free mass (W.kg(-1FFM during the 30-second Wingate Test (WT30 on bicycle ergometer (Monark 894E Peak bike, MONARK, Sweden. All WT30s were performed during the hockey season. Overall genotype frequencies were 50.6% GG homozygotes, 40.3% CG heterozygotes, and 9.1% CC homozygotes. We found statistically significant differences in Pmax.kg(-1 and marginally significant differences in Pmax.kg(-1FFM values in WT30 between carriers and non-carriers for C allele (14.6 ± 0.2 vs. 13.9 ± 0.3 W.kg(-1 and 15.8 ± 0.2 vs. 15.2 ± 0.3 W.kg(-1FFM, P = 0.036 and 0.12, respectively. Furthermore, Pmax.kg(-1FFM strongly positively correlated with the body weight only in individuals with GG genotypes (R = 0.55; p<0.001. Our results indicate that PPARA 7C carriers exhibited higher speed strength measures in WT30. We hypothesize that C allele carriers within the cohort of trained individuals may possess a metabolic advantage towards anaerobic metabolism.

  15. Wingate Anaerobic Test Peak Power and Anaerobic Capacity Classification for Men and Women Intercollegiate Athletes

    Science.gov (United States)

    2009-12-01

    Female firefighters Tae kwon do national team 7 endurance trained (ET) 6 sprinters (ST) 18-28 years old High school athletes Olympiclevel jodokas...results. men, 64 women). These data were preexisting data from the quarterly, semi-annual, or annual testing that these teams perform for training ...biathletes Trained cyclists Judo Soccer Rowers Nonathletes Olympic-level jodokas Competitive cyclists University hockey players (age: 20 years) Active

  16. The effects of bicycle frame geometry on muscle activation and power during a wingate anaerobic test.

    Science.gov (United States)

    Ricard, Mark D; Hills-Meyer, Patrick; Miller, Michael G; Michael, Timothy J

    2006-01-01

    The purpose of this study was to compare the effects of bicycle seat tube angles (STA) of (72° and 82°) on power production and EMG of the vastus laeralis (VL), vastus medialis (VM), semimembranous (SM), biceps femoris (BF) during a Wingate test (WAT). Twelve experienced cyclists performed a WAT at each STA. Repeated measures ANOVA was used to identify differences in muscular activation by STA. EMG variables were normalized to isometric maximum voluntary contraction (MVC). Paired t-tests were used to test the effects of STA on: peak power, average power, minimum power and percent power drop. Results indicated BF activation was significantly lower at STA 82° (482.9 ± 166.6 %MVC·s) compared to STA 72° (712.6 ± 265.6 %MVC·s). There were no differences in the power variables between STAs. The primary finding was that increasing the STA from 72° to 82° enabled triathletes' to maintain power production, while significantly reducing the muscular activation of the biceps femoris muscle. Key PointsRoad cyclists claim that bicycle seat tube angles between 72° and 76° are most effective for optimal performance in racing.Triathletes typically use seat tube angles greater than 76°. It is thought that a seat tube angle greater than 76° facilitates a smoother bike to run transition in the triathlon.Increasing the seat tube angle from 72 to 82 enabled triathletes' to maintain power production, while significantly reducing the muscular activation of the biceps femoris muscle.Reduced hamstring muscular activation in the triathlon frame (82 seat tube angle) may serve to reduce hamstring tightness following the bike phase of the triathlon, allowing the runner to use a longer stride length.

  17. The 1,500-m Rowing Performance is Highly Dependent on Modified Wingate Anaerobic Test Performance in National-Level Adolescent Rowers.

    Science.gov (United States)

    Maciejewski, Hugo; Rahmani, Abderrahmane; Chorin, Frédéric; Lardy, Julien; Giroux, Caroline; Ratel, Sébastien

    2016-11-01

    The aim of the current study was to determine whether the anaerobic performance assessed by a modified Wingate test could account for the 1,500-m rowing ergometer performance in young competitive rowers. Fourteen national-level adolescent rowers performed on a rowing ergometer i) a 30-s allout exercise (i.e., modified Wingate test) and ii) a 1,500-m all-out exercise (i.e., rowing performance). For each of these two exercises, the mean power output was considered as the main performance criterion (PWIN and P1500, respectively). PWIN was correlated to P1500 (r2 = .83, p rowing performance in competitive adolescent rowers. Therefore, the modified Wingate test could be used by rowing coaches to potentially identify talented young rowers.

  18. The effects of whole-body vibration on the Wingate test for anaerobic power when applying individualized frequencies.

    Science.gov (United States)

    Surowiec, Rachel K; Wang, Henry; Nagelkirk, Paul R; Frame, Jeffrey W; Dickin, D Clark

    2014-07-01

    Recently, individualized frequency (I-Freq) has been introduced with the notion that athletes may elicit a greater reflex response at differing levels (Hz) of vibration. The aim of the study was to evaluate acute whole-body vibration as a feasible intervention to increase power in trained cyclists and evaluate the efficacy of using I-Freq as an alternative to 30Hz, a common frequency seen in the literature. Twelve highly trained, competitive male cyclists (age, 29.9 ± 10.0 years; body height, 175.4 ± 7.8 cm; body mass, 77.3 ± 13.9 kg) participated in the study. A Wingate test for anaerobic power was administered on 3 occasions: following a control of no vibration, 30 Hz, or I-freq. Measures of peak power, average power (AP), and the rate of fatigue were recorded and compared with the vibration conditions using separate repeated measures analysis of variance. Peak power, AP, and the rate of fatigue were not significantly impacted by either the 30 Hz or I-Freq vibration interventions (p > 0.05). Given the trained status of the individuals in this study, the ability to elicit an acute response may have been muted. Future studies should further refine the vibration parameters used and assess changes in untrained or recreationally trained populations.

  19. Reliability and validity of a 20-s alternative to the wingate anaerobic test in team sport male athletes.

    Directory of Open Access Journals (Sweden)

    Ahmed Attia

    Full Text Available The intent of this study was to evaluate relative and absolute reliability of the 20-s anaerobic test (WAnT20 versus the WAnT30 and to verify how far the various indices of the 30-s Wingate anaerobic test (WAnT30 could be predicted from the WAnT20 data in male athletes. The participants were Exercise Science majors (age: 21.5±1.6 yrs, stature: 0.183±0.08 m, body mass: 81.2±10.9 kg who participated regularly in team sports. In Phase I, 41 participants performed duplicate WAnT20 and WAnT30 tests to assess reliability. In Phase II, 31 participants performed one trial each of the WAnT20 and WAnT30 to determine the ability of the WAnT20 to predict components of the WAnT30. In Phase III, 31 participants were used to cross-validate the prediction equations developed in Phase II. Respective intra-class correlation coefficients (ICC for peak power output (PPO (ICC = 0.98 and 0.95 and mean power output (MPO (ICC 0.98 and 0.90 did not differ significantly between WAnT20 and WAnT30. ICCs for minimal power output (POmin and fatigue index (FI were poor for both tests (range 0.53 to 0.76. Standard errors of the means (SEM for PPO and MPO were less than their smallest worthwhile changes (SWC in both tests; however, POmin and FI values were "marginal," with SEM values greater than their respective SWCs for both tests values. Stepwise regression analysis showed that MPO had the highest coefficient of predictability (R = 0.97, with POmin and FI considerable lower (R = 0.71 and 0.41 respectively. Cross-validation showed insignificant bias with limits of agreement of 0.99±1.04, 6.5±92.7 W, and 1.6±9.8% between measured and predicted MPO, POmin, and FI, respectively. WAnT20 offers a reliable and valid test of leg anaerobic power in male athletes and could replace the classic WAnT30.

  20. Reliability and validity of a 20-s alternative to the wingate anaerobic test in team sport male athletes.

    Science.gov (United States)

    Attia, Ahmed; Hachana, Younes; Chaabène, Helmi; Gaddour, Abdelmajid; Neji, Zied; Shephard, Roy J; Chelly, Mohamed Souhaiel

    2014-01-01

    The intent of this study was to evaluate relative and absolute reliability of the 20-s anaerobic test (WAnT20) versus the WAnT30 and to verify how far the various indices of the 30-s Wingate anaerobic test (WAnT30) could be predicted from the WAnT20 data in male athletes. The participants were Exercise Science majors (age: 21.5±1.6 yrs, stature: 0.183±0.08 m, body mass: 81.2±10.9 kg) who participated regularly in team sports. In Phase I, 41 participants performed duplicate WAnT20 and WAnT30 tests to assess reliability. In Phase II, 31 participants performed one trial each of the WAnT20 and WAnT30 to determine the ability of the WAnT20 to predict components of the WAnT30. In Phase III, 31 participants were used to cross-validate the prediction equations developed in Phase II. Respective intra-class correlation coefficients (ICC) for peak power output (PPO) (ICC = 0.98 and 0.95) and mean power output (MPO) (ICC 0.98 and 0.90) did not differ significantly between WAnT20 and WAnT30. ICCs for minimal power output (POmin) and fatigue index (FI) were poor for both tests (range 0.53 to 0.76). Standard errors of the means (SEM) for PPO and MPO were less than their smallest worthwhile changes (SWC) in both tests; however, POmin and FI values were "marginal," with SEM values greater than their respective SWCs for both tests values. Stepwise regression analysis showed that MPO had the highest coefficient of predictability (R = 0.97), with POmin and FI considerable lower (R = 0.71 and 0.41 respectively). Cross-validation showed insignificant bias with limits of agreement of 0.99±1.04, 6.5±92.7 W, and 1.6±9.8% between measured and predicted MPO, POmin, and FI, respectively. WAnT20 offers a reliable and valid test of leg anaerobic power in male athletes and could replace the classic WAnT30.

  1. The dynamics of distance, velocity and acceleration of power output in the 30-s Wingate Anaerobic Test.

    Science.gov (United States)

    Bell, W; Cobner, D

    2011-02-01

    The purpose of the present study was to analyse the dynamics of distance, velocity and acceleration of the 30-s Wingate Anaerobic Test. Participants were 53 young adult Rugby Union football players of mean age 21.6±2.5 yr, 180.5±7.2 cm height and 89.3±12.7 kg body mass. Measurements of power were obtained using a friction-belt cycle ergometer (Monark 864, Varberg, Sweden). Individual data were aligned according to peak power output, which resulted in a mean value of 1 216±256 W, compared with one of 1 180±256 W when calculated cross-sectionally (pMathcad. Distance, velocity and acceleration curves were plotted simultaneously at 1 s intervals before and after peak power output (-4 s to +28 s). The initial rise of the distance curve was the result of a general trend in decreasing positive velocities as far as peak power output, followed thereafter by a gradual deterioration of power, the result of negative velocities from peak power output to +28 s peak power output. The initial values of the acceleration curve showed a fluctuating decelerating trend of negative values to peak power output; subsequently all values remained positive running along the zero acceleration time axis. Coefficients of correlation between peak power output and power values at -1 s to -3 s were 0.80, 0.65 and 0.63 respectively (p<0.001). The relationship between velocity and acceleration was - 0.968 (p<0.01). © Georg Thieme Verlag KG Stuttgart · New York.

  2. Intermittent theta burst over M1 may increase peak power of a Wingate anaerobic test and prevent the reduction of voluntary activation measured with transcranial magnetic stimulation

    Directory of Open Access Journals (Sweden)

    Louis-Solal Giboin

    2016-07-01

    Full Text Available Despite the potential of repetitive transcranial magnetic stimulation (rTMS to improve performances in patients suffering from motor neuronal afflictions, its effect on motor performance enhancement in healthy subjects during a specific sport task is still unknown. We hypothesised that after an intermittent theta burst (iTBS treatment, performance during the Wingate Anaerobic Test (WAnT, will increase and supraspinal fatigue following the exercise will be lower in comparison to a control treatment.Ten subjects participated in two randomised experiments consisting of a WAnT 5 minutes after either an iTBS or a control treatment. We determined voluntary activation (VA of the right knee extensors with TMS (VATMS and with peripheral nerve stimulation (VAPNS of the femoral nerve, before and after the WAnT. T-tests were applied to the WAnT results and a 2 way within subject ANOVA was applied to VA results. The iTBS treatment increased the peak power and the maximum pedalling cadence and suppressed the reduction of VATMS following the WAnT compared to the control treatment. No behavioural changes related to fatigue (mean power and fatigue index were observed.These results indicate for the first time that iTBS could be used as a potential intervention to improve anaerobic performance in a sport specific task.

  3. İKİ ANAEROSİK GÜÇ TESTİ ARASINDAKİ İLİŞKİ / RELATIONSHIP BETWEEN WINGATE AND BOSCO ANAEROBIC POWER TESTS

    OpenAIRE

    Atan, Tülin; Atan, Aşkın; Kishalı, Necip Fazıl

    2017-01-01

    Bu ryali§ma anaerobik test/erden Wingate Testi (WAN) ile 30sn 90k/u 5/ryrama Testi (95) gury degerleriarasmdaki iJi§kiye bakmak amaci ile yaptfm/§t/r.15 erkek beden egitimi ve spor b6!IJmu ogrencisine (ya§.22.23 ±2. 17 yll ; vucut aglrllg/ 78. 1h8.57 kg ; boyuzunlugu: 184.48±2.84 bir hafta ara ile s/ras'Yla WAN ve 95 test/ed uygulanml§tlr. WAN'da anaerobik guryMonark 834E tipi kefeli bisiklet ergometresinde, 95'de ise Psion organiser 1646'lik bilgi banka...

  4. Wingate Test as a Strong Predictor of 1500-m Performance in Elite Speed Skaters.

    Science.gov (United States)

    Hofman, Nico; Orie, Jac; Hoozemans, Marco J M; Foster, Carl; de Koning, Jos J

    2017-11-01

    Wingate test scores are strongly associated with anaerobic capacity in athletes involved in speed-endurance sports. In speed skating Wingate results are known to predict performance cross-sectionally but have not been investigated relative to their ability to predict performance longitudinally. To investigate whether Wingate tests performed during summer training are predictive of 1500-m speed-skating performance the subsequent winter in elite speed skaters. Wingate test results from the summer training periods and 1500-m performances during the subsequent winter were analyzed over a 3-y period in 5 female and 8 male elite (Olympic, World Championship, and World Cup medalists) speed skaters. Regression analyses using generalized estimating equations (GEE) were used to estimate the relationship between Wingate test variables and 1500-m speed-skating performance. Wingate peak power (PP) and mean power (MP) were used to predict 1500-m time and 400-m lap times. Improvements of 1 W/kg on PP and MP in women predict improvements of -0.75 s and -2.05 s, respectively, on 1500-m time (World Record 110.85 s). In men, improvements in PP and MP were associated with performance improvements of -0.92 s and -2.32 s on 1500-m time per 1 W/kg (World Record 101.04 s). Wingate test results achieved during the summer training period are a good predictor of improvements in 1500-m speed-skating performance during the subsequent winter. For the smallest worthwhile improvement in 1500-m performance, a gain in PP and MP of 2.1% and 1.4% (0.38 and 0.14 W/kg) for females and 1.2% and 0.9% (0.29 and 0.12 W/kg) for males is needed.

  5. Influence of selected phases of the menstrual cycle on performance in Special judo fitness test and Wingate test

    Directory of Open Access Journals (Sweden)

    Miloš Štefanovský

    2016-09-01

    Full Text Available Background: Several scientific papers in recent years dealt with the menstrual cycle and its impact on female sport performance. No differences have been found in aerobic performance, but the results of the studies dealing with the influence of the menstrual cycle on anaerobic performance are often controversial. Objective: The aim of this study was to verify the effect of selected phases of the menstrual cycle on anaerobic performance of judokas in the Wingate test and Special judo fitness test. Methods: The research sample was composed of 8 young female judokas (age 18.14 ± 3.44 years; body weight 63.86 ± 10.42 kg; height 165.43 ± 5.09 cm; judo practice 11.14 ± 3.13 years. The observed parameters in the Wingate test were as follows: a anaerobic peak power; b anaerobic capacity; c fatigue index; d blood lactate in the 5th minute after completing the test. In Special judo fitness test (SJFT we measured the following parameters: a number of throws in the first period; b second period; c third period; d total number of throws; e SJFT index. For the processing and evaluation of obtained data, we used the non-parametric Wilcoxon t-test and effect sizes are described by Cohen's d. Results: No significant changes have been observed in any of those parameters in the Wingate test and Special judo fitness test due to changes of menstrual phases, except of number of throws in the first 15-s period of the Special judo fitness test with better performance in luteal phase (p = .03; Cohen's d = 1.149. Conclusion: Better anaerobic performance in luteal phase could be a result of potential larger phosphocreatine and adenosine triphosphate stores, which can have a positive effect on high intensity specific judo performance.

  6. Effeti di un test di Wingate sull´eccitazione corticale e sul sistema nervoso centrale in ciclisti allenati

    OpenAIRE

    Clemente Suárez, Vicente Javier

    2015-01-01

    The aim of the present research was to analyze the effect of a maximum anaerobic Wingate test on central nervous system (CNS) and cortical arousal in trained cyclists.We analyzed 8 trained cyclists (65.8±5.6 kg, 175.5±6.0 cm, 16.7±0.8 years, 10.9±2.5% fat, 33.1±3.83 kg muscular mass, VO2max [mL/kg/min], 60.9±4.1, VO2max [mL]: 4027.8±287.5). Participants conducted before and after a Wingate test a critical flicker fusion threshold test (CFFTT) to analyze cortical arousal and fatigue of CNS. Af...

  7. Isometric knee extensor fatigue following a Wingate test: peripheral and central mechanisms.

    Science.gov (United States)

    Fernandez-del-Olmo, M; Rodriguez, F A; Marquez, G; Iglesias, X; Marina, M; Benitez, A; Vallejo, L; Acero, R M

    2013-02-01

    Central and peripheral fatigue have been explored during and after running or cycling exercises. However, the fatigue mechanisms associated with a short maximal cycling exercise (30 s Wingate test) have not been investigated. In this study, 10 volunteer subjects performed several isometric voluntary contractions using the leg muscle extensors before and after two bouts of cycling at 25% of maximal power output and two bouts of Wingate tests. Transcranial magnetic stimulation (TMS) and electrical motor nerve stimulation (NM) were applied at rest and during the voluntary contractions. Maximal voluntary contraction (MVC), voluntary activation (VA), twitch amplitude evoked by electrical nerve stimulation, M wave and motor potential evoked by TMS (MEP) were recorded. MVC, VA and twitch amplitude evoked at rest by NM decreased significantly after the first and second Wingate tests, indicating central and peripheral fatigue. MVC and VA, but not the twitch amplitude evoked by NM, recovered before the second Wingate test. These results suggest that the Wingate test results in a decrease in MVC associated with peripheral and central fatigue. While the peripheral fatigue is associated with an intramuscular impairment, the central fatigue seems to be the main reason for the Wingate test-induced impairment of MVC. © 2011 John Wiley & Sons A/S.

  8. Acute Effects of Three Different Stretching Protocols on the Wingate Test Performance

    Science.gov (United States)

    Franco, Bruno L.; Signorelli, Gabriel R.; Trajano, Gabriel S.; Costa, Pablo B.; de Oliveira, Carlos G.

    2012-01-01

    The purpose of this study was to examine the acute effects of different stretching exercises on the performance of the traditional Wingate test (WT). Fifteen male participants performed five WT; one for familiarization (FT), and the remaining four after no stretching (NS), static stretching (SS), dynamic stretching (DS), and proprioceptive neuromuscular facilitation (PNF). Stretches were targeted for the hamstrings, quadriceps, and calf muscles. Peak power (PP), mean power (MP), and the time to reach PP (TP) were calculated. The MP was significantly lower when comparing the DS (7.7 ± 0.9 W/kg) to the PNF (7.3 ± 0.9 W/kg) condition (p stretching providing the lowest result. A consistent increase of TP was observed after all stretching exercises when compared to NS. The results suggest the type of stretching, or no stretching, should be considered by those who seek higher performance and practice sports that use maximal anaerobic power. Key points The mean power was significantly lower when comparing dynamic stretching.to proprioceptive neuromuscular facilitation. For peak power, significant differences were observed between more comparisons, with proprioceptive neuromuscular facilitation stretching providing the lowest result. A consistent increase of time to reach the peak was observed after all stretching exercises when compared to non-stretching. The type of stretching, or no stretching, should be considered by those who seek higher performance and practice sports that use maximal anaerobic power. PMID:24149116

  9. Elite Female Athletes' Ventilatory Compensation to Decreased Inspired O[subscript 2] during the Wingate Test

    Science.gov (United States)

    Fallon, Sarah; Belcoe, Ana; Shawcross, Callan; May, Alyssa; Monteverde, Cristina; McCann, Daniel

    2015-01-01

    Purpose: The purpose of this study was to determine if anaerobic performance as measured by the Wingate is decremented in elite female athletes when fraction of inspired oxygen is decreased from 20.9% to 10%. Method: Nine collegiate female soccer players (M[subscript weight] = 63.2 ± 10 kg, M[subscript height] = 164 ± 4.7 cm, M[subscript age] =…

  10. ACUTE EFFECTS OF THREE DIFFERENT STRETCHING PROTOCOLS ON THE WINGATE TEST PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Bruno L. Franco

    2012-03-01

    Full Text Available The purpose of this study was to examine the acute effects of different stretching exercises on the performance of the traditional Wingate test (WT. Fifteen male participants performed five WT; one for familiarization (FT, and the remaining four after no stretching (NS, static stretching (SS, dynamic stretching (DS, and proprioceptive neuromuscular facilitation (PNF. Stretches were targeted for the hamstrings, quadriceps, and calf muscles. Peak power (PP, mean power (MP, and the time to reach PP (TP were calculated. The MP was significantly lower when comparing the DS (7.7 ± 0.9 W/kg to the PNF (7.3 ± 0.9 W/kg condition (p < 0.05. For PP, significant differences were observed between more comparisons, with PNF stretching providing the lowest result. A consistent increase of TP was observed after all stretching exercises when compared to NS. The results suggest the type of stretching, or no stretching, should be considered by those who seek higher performance and practice sports that use maximal anaerobic power.

  11. Anaerobic exercise testing in rehabilitation: A systematic review of available tests and protocols.

    Science.gov (United States)

    Krops, Leonie A; Albada, Trijntje; van der Woude, Lucas H V; Hijmans, Juha M; Dekker, Rienk

    2017-04-06

    Anaerobic capacity assessment in rehabilitation has received increasing scientific attention in recent years. However, anaerobic capacity is not tested consistently in clinical rehabilitation practice. This study reviews tests and protocols for anaerobic capacity in adults with various disabilities (spinal cord injury, cerebral palsy, cerebral vascular accident, lower-limb amputation(s)) and (able-bodied) wheelchair users. PubMed, CINAHL and Web of Science. Papers were screened by 2 independent assessors, and were included when anaerobic exercise tests were performed on the above-selected subject groups. Included articles were checked for methodological quality. A total of 57 papers was included. Upper-body testing [56 protocols] was conducted with arm crank [16] and wheelchair tests [40]. With a few [2] exceptions, modified Wingate (Wingate) protocols and wheelchair sprint tests dominated upper-body anaerobic testing. In lower-body anaerobic work [11], bicycle [3] and recumbent [1], and overground tests [7] were used, in which Wingate, sprint or jump protocols were employed. When equipment is available a Wingate protocol is advised for assessment of anaerobic capacity in rehabilitation. When equipment is not avail-able a 20-45 s sprint test is a good alternative. Future research should focus on standardized tests and protocols specific to different disability groups.

  12. TIME-OF-DAY EFFECTS ON EMG PARAMETERS DURING THE WINGATE TEST IN BOYS

    Directory of Open Access Journals (Sweden)

    Hichem Souissi

    2012-09-01

    Full Text Available In boys, muscle power and strength fluctuate with time-of-day with morning nadirs and afternoon maximum values. However, the exact underlying mechanisms of this daily variation are not studied yet. Thus, the purpose of this study was to examine the time-of-day effects on electromyographic (EMG parameters changes during a Wingate test in boys. Twenty-two boys performed a 30-s Wingate test (measurement of muscle power and fatigue at 07:00 and 17:00-h on separate days. Surface EMG activity was recorded in the Vastus lateralis, rectus femoris and vastus medialis muscles throughout the test and analyzed over a 5-s span. The root-mean-square (RMS and mean-power-frequency (MPF were calculated. Neuromuscular efficiency (NME was estimated from the ratio of power to RMS. Muscle power (8.22 ± 0.92 vs. 8.75 ± 0.99 W·kg-1 for peak power and 6.96 ± 0. 72 vs. 7.31 ± 0.77 W·kg-1 for mean power, p < 0.001 and fatigue (30.27 ± 7.98 vs. 34.5 ± 10. 15 %, p < 0.05 during the Wingate test increased significantly from morning to evening. Likewise, MPF (102.14 ± 18.15 vs. 92.38 ± 12.39 Hz during the first 5-s, p < 0.001 and NME (4.78 ± 1.7 vs. 3.88 ± 0.79 W·mV-1 during the first 5-s, p < 0.001 were higher in the evening than the morning; but no significant time-of-day effect was noticed for RMS. Taken together, these results suggest that peripheral mechanisms are more likely the cause of the child's diurnal variations of muscle power and fatigue during the Wingate test

  13. Examination of relationship between 30 second wingate test performance and spirometric respiratory functions in young adults

    Directory of Open Access Journals (Sweden)

    C Arslan

    2009-07-01

    Full Text Available Objective: This work has been planed to investigate whether the correlation between one of the important component of the sports performance spirometric respiratory function (SRF and 30 s Wingate Test (WT parameters of young adults who have different physical fitness level. Materials and Methods: This work included a total of 166 subjects those are 98 young boys (20.30±1.93 and 68 young girls (19.65±2.18. The subjects were divided into two groups namely regular exercises group (EG who make a regular exercises during 4.0±1.50 years and sedentary groups (SG. Both group’s subjects have similar age, height, weight and body mass index (BMI kg/m2. All the subjects were performed spirometric respiratory function test and WT power performance test. Statistical analyses were performed by SPSS computer program and the groups were compared to each other by using Independent Samples t test calculation and the correlation relation levels were calculated by using linear regression analysis. Results: In the view of physical peculiarities, it has not been found any difference between research groups that EG and SG (P>0.05. In the meaning of the measured spirometric respiratory functions and WT power performance, with the advantage of making regular sports, according to SG groups, the boys and girls EG groups showed differences (P<0.05. The correlational relationship between the spirometric and WT power parameters; it has been observed significant correlation between peak power (PP, mean power (MP, peak power/weight (PP/Wkg, mean power/weight (MP/Wkg form WT parameters and VC, FVC, FEV1, FEV1/FVC (% FEF25-75, PEF and MVV form respiration function (P<0.05 and P<0.001. On the other hand, it has not been found any significant correlation between WT anaerobic fatigue index (AFI % and respiratory functions (P<0.05. Conclusion: In this work, the tested spirometric respiratory functions have got an active role in the WT power parameters. It has been confirmed that

  14. Test-retest reliability, criterion-related validity, and minimal detectable change of score on an abbreviated Wingate test for field sport participants.

    Science.gov (United States)

    Hachana, Younes; Attia, Ahmed; Nassib, Sabri; Shephard, Roy J; Chelly, Mohamed Souhaiel

    2012-05-01

    Repeat measurements in 69 young adults were performed to assess the test-retest reliability and the 95% confidence interval of the difference in score between paired observations (MDC95) of a Wingate test as abbreviated for field sport participants (test of a 15-second duration [15-secT]). Test-retest reliability was excellent for peak power output (PPO) and mean power output (MPO), independently of their mode of expression and was moderate for the fatigue index (FI). The standard errors of measurement (SEM) for absolute, relative, and derived PPO and MPO values ranged from 2.6 to 3.7%, all being smaller than the corresponding smallest worthwhile change (SWC). In contrast, FI values were rated as "marginal," with an SEM (9.6%) greater than the SWC (1.7). The range of MDC95 values for PPO and MPO were 9.9-10.4 and 7.37-7.42%, respectively. The absolute MPO showed the highest test-retest reliability and was the most effective in detecting real change. A second phase of the study evaluated the criterion-related validity of the 15-secT in 43 young men who performed 15-secT and standard 30-second Wingate anaerobic test (30-secT) in random order, on 2 separate occasions. There were no significant intertest differences in absolute, relative, or derived PPO. However, the FI for the 30-secT was greater than that for the 15-secT. Intertest correlations were highly significant for both MPOs and FIs. These findings suggest that the abbreviated Wingate test offers a reliable and valid tool for the evaluation of PPO and MPO, at least in young physical education students.

  15. Effects of acute creatine supplementation on iron homeostasis and uric acid-based antioxidant capacity of plasma after wingate test

    Directory of Open Access Journals (Sweden)

    Barros Marcelo P

    2012-06-01

    Full Text Available Abstract Background Dietary creatine has been largely used as an ergogenic aid to improve strength and athletic performance, especially in short-term and high energy-demanding anaerobic exercise. Recent findings have also suggested a possible antioxidant role for creatine in muscle tissues during exercise. Here we evaluate the effects of a 1-week regimen of 20 g/day creatine supplementation on the plasma antioxidant capacity, free and heme iron content, and uric acid and lipid peroxidation levels of young subjects (23.1 ± 5.8 years old immediately before and 5 and 60 min after the exhaustive Wingate test. Results Maximum anaerobic power was improved by acute creatine supplementation (10.5 %, but it was accompanied by a 2.4-fold increase in pro-oxidant free iron ions in the plasma. However, potential iron-driven oxidative insult was adequately counterbalanced by proportional increases in antioxidant ferric-reducing activity in plasma (FRAP, leading to unaltered lipid peroxidation levels. Interestingly, the FRAP index, found to be highly dependent on uric acid levels in the placebo group, also had an additional contribution from other circulating metabolites in creatine-fed subjects. Conclusions Our data suggest that acute creatine supplementation improved the anaerobic performance of athletes and limited short-term oxidative insults, since creatine-induced iron overload was efficiently circumvented by acquired FRAP capacity attributed to: overproduction of uric acid in energy-depleted muscles (as an end-product of purine metabolism and a powerful iron chelating agent and inherent antioxidant activity of creatine.

  16. Relationships Between Anaerobic Performance, Field Tests and Game Performance of Sitting Volleyball Players

    OpenAIRE

    Marszalek Jolanta; Molik Bartosz; Gomez Miguel Angel; Skučas Kęstutis; Lencse-Mucha Judit; Rekowski Witold; Pokvytyte Vaida; Rutkowska Izabela; Kaźmierska-Kowalewska Kalina

    2015-01-01

    The aim of this study was to evaluate relationships between anaerobic performance, field tests, game performance and anthropometric variables of sitting volleyball players. Twenty elite Polish sitting volleyball players were tested using the 30 s Wingate Anaerobic Test for arm crank ergometer and participated in six physical field tests. Heights in position to block and to spike, as well as arm reach were measured. Players were observed during the game on the court in terms of effectiveness o...

  17. Reliability and validity of the 30-s continuous jump test for anaerobic fitness evaluation.

    Science.gov (United States)

    Dal Pupo, Juliano; Gheller, Rodrigo G; Dias, Jonathan A; Rodacki, André L F; Moro, Antônio R P; Santos, Saray G

    2014-11-01

    To determine the test-retest reliability and concurrent validity of the 30-s continuous jump (CJ30) test using the Wingate test as a reference. Descriptive validity study. Twenty-one male volleyball players (23.8 ± 3.8 years; 82.5 ± 9.1 kg; 185 ± 4.7 cm) were tested in three separate sessions. The first and second sessions were used to assess the reliability of the CJ30 while in the third session the Wingate test was performed. In the continuous jump test, consisting of maximal continuous jumps performed for 30s, jump height was determined by video kinematic analysis. Blood samples were collected after each test to determine lactate concentration. The CJ30 showed excellent test-retest reliability for the maximal jump height (ICC = 0.94), mean vertical jump height (ICC = 0.98) and fatigue index (ICC = 0.87). Peak lactate showed moderate reliability (ICC = 0.45). Large correlations were found between the mean height of the first four jumps of CJ30 and the peak power of the Wingate (r = 0.57), between the mean vertical jump height of CJ30 and the mean power of the Wingate (r = 0.70) and between the lactate peak of CJ30 and Wingate (r = 0.51). A moderate correlation of fatigue index between CJ30 and the Wingate was found (r = 0.43). The continuous jump is a reliable test and measures some of the same anaerobic properties as WAnT. The correlations observed in terms of anaerobic indices between the tests provide evidence that the CJ30 may adequately assess anaerobic performance level. Copyright © 2013 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  18. Effects of time of day and the wingate test on appetite perceptions, food intake and plasma levels of adipokines.

    Science.gov (United States)

    Bilski, J; Jaworek, J; Pokorski, J; Nitecki, J; Nitecka, E; Pokorska, J; Mazur-Bialy, A; Szklarczyk, J

    2016-10-01

    It has been demonstrated that several aspects of adipose-related physiology including adipokine release, exhibit daily oscillations. Physical exercise exerts a strong influence on adipokine release and a possible reverse disruption of peripheral circadian clocks. The aim of this study was to establish the effects of time of day and the Wingate test on appetite perception, food intake and plasma levels of adipokines. Twenty-four moderately active non-smoking males (mean ± S.D. age: 27.1 ± 3.1 years; height: 1.79 ± 0.1 m; weight: 76.1 ± 11.7 kg) were recruited for this study and divided in two groups; one fed with an ad libitum test meal and another one without an ad libitum test meal. Each subject participated in the following studies performed at 11:00 and 23:00 hours on separate days: 1) Exercise study (ES): a 30-second Wingate Anaerobic Test (WAnT), and 2) sedentary study (SS). Subjects rated their appetite perceptions (hunger and prospective food consumption) on a 100-milimeter visual analogue scale (VAS) at baseline, after exercise, after test meal and during the postprandial/control period. At those time points blood samples were obtained for the measurement of plasma leptin, visfatin and apelin concentrations. Appetite perception and energy intake results at test meal decreased in response to WAnT in comparison with sedentary subjects. Time of day had no statistically significant effect on energy intake but the appetite perception score after test meal at 24:00 hours was statistically higher than that after test meal at 12:00 hours. No significant differences in the tested plasma adipokine concentrations between the trials existed at baseline, however, all plasma adipokine levels at 24:00 hours were higher than those at 12:00 hours. Plasma apelin concentrations after WAnT were significantly higher than its pre-exercise value at 12:00 hours, unlike those at 24:00 hours. Sedentary experiments showed a modest, yet significant, rise in plasma apelin levels

  19. Oxygen uptake during Wingate tests for arms and legs in swimmers and water polo players

    Directory of Open Access Journals (Sweden)

    Colantonio Emilson

    2003-01-01

    Full Text Available OBJECTIVE: The aim of the present study is to compare the values of the maximal oxygen uptake (O2 max during two consecutive bouts in Wingate tests for arms and legs in swimmers (S and water polo players (WP. METHODS: Sample - seven national level athletes (4 S and 3 WP, age 17,90 ± 2,14 years, body mass 71,41 ± 6,84 kg, height 176,65 ± 7,02 cm, % body fat 13,23 ± 4,18. Two Wingate bouts with 30 sec each with 3 min interval between them, for arms and legs in alternated days. Oxygen uptake: breath-by-breath using the gas analysis system K4 b² Cosmed. Statistical analysis: Wilcoxon test for dependent variables and Kolmogorov-Smirnov test for independent variables. RESULTS: The mean values found at the O2 peak (PO2, mean power (MP and peak power (PP for each bout of the Wingate test, for arms and legs. For Arms: PO2 = 55.16 ± 5.72 ml.kg-1.min-1, MP = 5.28 ± 0.59 watts.kg-1 and PP = 6.71 ± 0.88 watts.kg-1 got in the first bout (1st Arms and PO2 = 60.12 ± 6.10 ml.kg-1.min-1, MP = 5.03 ± 0.40 watts.kg-1 and PP = 6.25 ± 0.51 watts.kg-1, got in the second bout (2nd Arms. For legs: PO2 = 55.66 ± 6.85 ml.kg-1.min-1, MP = 4.75 ± 1.79 watts.kg-1 and PP = 7.44 ± 1.96 watts.kg-1 got in the first bout (1st Legs and PO2 = 62.09 ± 5.99 ml.kg-1.min-1, MP = 4.28 ± 1.47 watts.kg-1 and PP = 6.68 ± 1.63 watts.kg-1 got in the second bout (2nd Legs. DISCUSSION AND CONCLUSION: All variables studied did not present significant difference among arms and legs, as much the first as the second bout for arms for PO2 (p < 0.05. There was no difference between the PM mean values of the first and the second bout. But the mean of the second bout of legs was significant smaller than the first bout (p < 0.05. For the PP variable there was no difference among the mean values to the first and second bout as much for arms as for legs. It looks like to exist larger magnitude to O2 adjustment for arms than legs, that could be associated to specific demands to which S

  20. Comparison of Effect of One Course of Intense Exercise (Wingate test) on Serum Levels of Interleukin-17 in Different Groups of Athletes.

    Science.gov (United States)

    Tofighee, Asghar; Khazaei, Hossein Ali; Jalili, Arman

    2014-12-01

    Research on the effects of exercise on immune function, has a wide range of sporting activities. Study on the long-term effects of regular exercise on serum levels of cytokines such as interleukin-17 have shown that moderate and regular exercise, has an important role in the prevention and treatment of many diseases. Exhaustive exercise has a deep effect on cellular, humoral, innate immunity and the amount of cytokines of an athlete's immune system. So this study was designed to compare the effect of one course of exhaustive exercise on serum levels of interleukin (IL)-17 in different groups of athletes. Forty professional athletes with a mean age of 25.1 ± 5.0 years, divided equally in 4 groups (handball, volleyball, Sepak-takraw and climbing) were selected for this purpose. 30 second Wingate test for each athlete was used to assess anaerobic power. Blood samples before, immediately after and 2 hours after exercise was collected and the amount of serum IL-17 was measured. The results showed that the level of IL-17 in the study groups before and after the two hours exercise did not significantly change in all four groups. The results showed that short anaerobic exercise has no effect on the level of IL-17.

  1. A influência do encorajamento verbal a da recompensa no desempenho do teste de Wingate em adolescentes

    OpenAIRE

    Pombo, Simão Pedro da Silva

    2005-01-01

    Dissertação de licenciatura apresentada à Faculdade de Ciências do Desporto e Educação Física da Universidade de Coimbra Este estudo teve como objectivo analisar os efeitos da recompensa e encorajamento verbal no desempenho do teste do Wingate, sendo analisadas as seguintes variáveis, Peak Power, Mean Power, Índice de Fadiga, e Trabalho Total. Trinta sujeitos do sexo masculinos, com uma média de idades de 15,6 anos submeteram-se por duas vezes à realização do WAnT. Numa primeira situaçã...

  2. Crossfit training changes brain-derived neurotrophic factor and irisin levels at rest, after wingate and progressive tests, and improves aerobic capacity and body composition of young physically active men and women.

    Science.gov (United States)

    Murawska-Cialowicz, E; Wojna, J; Zuwala-Jagiello, J

    2015-12-01

    . There were no differences in irisin levels between the baseline and 3 months after the training after Wingate and progressive tests. A beneficial influence of CrossFit training on the subjects' body composition, anaerobic capacity and cardiovascular fitness as well as an increase in BDNF makes it possible to assume that this type of training could have a very high application value, especially in a therapeutic process leading to improving a patient's wellbeing.

  3. Validity and reliability of the Hawaii anaerobic run test.

    Science.gov (United States)

    Kimura, Iris F; Stickley, Christopher D; Lentz, Melissa A; Wages, Jennifer J; Yanagi, Kazuhiko; Hetzler, Ronald K

    2014-05-01

    This study examined the reliability and validity of the Hawaii anaerobic run test (HART) by comparing anaerobic capacity measures obtained to those during the Wingate Anaerobic Test (WAnT). Ninety-six healthy physically active volunteers (age, 22.0 ± 2.8 years; height, 163.9 ± 9.5 cm; body mass, 70.6 ± 14.7 kg; body fat %, 19.29 ± 5.39%) participated in this study. Each participant performed 2 anaerobic capacity tests: the WAnT and the HART by random assignment on separate days. The reliability of the HART was calculated from 2 separate trials of the test and then determined through intraclass correlation coefficients (ICCs). Blood samples were collected, and lactate was analyzed both pretest and posttest for each of the 2 exercise modes. Heart rate and rate of perceived exertion were also measured pre- and post-exercise. Hawaii anaerobic run test peak and mean momentum were calculated as body mass times highest or average split velocity, respectively. Intraclass correlation coefficients between trials of the HART for peak and mean momentum were 0.98 and 0.99, respectively (SEM = 18.8 and 25.7, respectively). Validity of the HART was established through comparison of momentum on the HART with power on the WAnT. High correlations were found between peak power and peak momentum (r = 0.88), as well as mean power and mean momentum (r = 0.94). The HART was considered to be a reliable test of anaerobic power. The HART was also determined to be a valid test of anaerobic power when compared with the WAnT. When testing healthy college-aged individuals, the HART offers an easy and inexpensive alternative maximal effort anaerobic power test to other established tests.

  4. Development of a specific anaerobic field test for aerobic gymnastics.

    Directory of Open Access Journals (Sweden)

    Christiano Robles Rodrigues Alves

    Full Text Available The current investigation aimed to develop a valid specific field test to evaluate anaerobic physical performance in Aerobic Gymnastics athletes. We first designed the Specific Aerobic Gymnast Anaerobic Test (SAGAT, which included gymnastics-specific elements performed in maximal repeated sprint fashion, with a total duration of 80-90 s. In order to validate the SAGAT, three independent sub-studies were performed to evaluate the concurrent validity (Study I, n=8, the reliability (Study II, n=10 and the sensitivity (Study III, n=30 of the test in elite female athletes. In Study I, a positive correlation was shown between lower-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.69, CI: -0.94 to 0.03 and Peak power: p = 0.02, r = -0.72, CI: -0.95 to -0.04 and between upper-body Wingate test and SAGAT performance (Mean power: p = 0.03, r = -0.67, CI: -0.94 to 0.02 and Peak power: p = 0.03, r = -0.69, CI: -0.94 to 0.03. Additionally, plasma lactate was similarly increased in response to SAGAT (p = 0.002, lower-body Wingate Test (p = 0.021 and a simulated competition (p = 0.007. In Study II, no differences were found between the time to complete the SAGAT in repeated trials (p = 0.84; Cohen's d effect size = 0.09; ICC = 0.97, CI: 0.89 to 0.99; MDC95 = 0.12 s. Finally, in Study III the time to complete the SAGAT was significantly lower during the competition cycle when compared to the period before the preparatory cycle (p < 0.001, showing an improvement in SAGAT performance after a specific Aerobic Gymnastics training period. Taken together, these data have demonstrated that SAGAT is a specific, reliable and sensitive measurement of specific anaerobic performance in elite female Aerobic Gymnastics, presenting great potential to be largely applied in training settings.

  5. Validity of the running anaerobic sprint test for assessing anaerobic power and predicting short-distance performances.

    Science.gov (United States)

    Zagatto, Alessandro M; Beck, Wladimir R; Gobatto, Claudio A

    2009-09-01

    The purpose of this study was to investigate the reliability and validity of the running anaerobic sprint test (RAST) in anaerobic assessment and predicting short-distance performance. Forty members of the armed forces were recruited for this study (age 19.78 +/- 1.18 years; body mass 70.34 +/- 8.10 kg; height 1.76 +/- 0.53 m; body fat 15.30 +/- 5.65 %). The RAST test was applied to six 35-meter maximal running performances with a 10-second recovery between each run; the peak power, mean power, and the fatigue index were measured. The study was divided in two stages. The first stage investigated the reliability of the RAST using a test-retest method; the second stage aimed to evaluate the validity of the RAST comparing the results with the Wingate test and running performances of 35, 50, 100, 200, and 400 m. There were not significant differences between test-retest scores in the first stage of the study (p > 0.05) and were found significant correlations between these variables (intraclass correlation coefficient approximately = 0.88). The RAST had significant correlations with the Wingate test (peak power r = 0.46; mean power r = 0.53; fatigue index r = 0.63) and 35, 50, 100, 200, and 400 m performances scores (p RAST for measuring anaerobic power is that it allows for the execution of movements more specific to sporting events that use running as the principal style of locomotion, is easily applied and low cost, and due to its simplicity can easily be incorporated into routine training. We concluded that this procedure is reliable and valid, and can be used to measure running anaerobic power and predict short-distance performances.

  6. Effects of kinesio taping on anaerobic power and capacity results.

    Science.gov (United States)

    Harmanci, Halit; Kalkavan, Arslan; Karavelioglu, Mihri B; Yuksel, Oğuzhan; Şentürk, Aydin; Gülaç, Meryem; Altinok, Betül

    2016-06-01

    Kinesio taping is a therapeutic method used by physiotherapists during musculoskeletal and neuromuscular disorders. Efficacy of the kinesio taping implementation on sport performance is inconsistent. The purpose of this study was to determine the effects of kinesio taping on 30 second-repeated jump power, wingate anaerobic power and wingate anaerobic capacity results. Thirty one healthy male athletes volunteered to participate in this study. The subjects were randomly assigned to one of two groups: a kinesio taping group (16 subjects; X age: 21.87±2.02 years) and a without kinesio taping group (15 subjects; X age: 21.66±1.67 years). The Kinesio taping group was taped with a Y-shaped kinesio tape at the quadriceps muscles according to the Kenzo Kase's Kinesio taping manual. A dependent t-test was used to compare the anaerobic power and capacity measurements before and after the kinesio taping application. No significant differences were found for absolute wingate anaerobic power, relative wingate anaerobic power, absolute wingate anaerobic capacity, relative wingate anaerobic capacity and 30 second-repeated jump power outputs after the kinesio taping application (P>0.05).

  7. Validity of the Pediatric Running-Based Anaerobic Sprint Test to Determine Anaerobic Performance in Healthy Children.

    Science.gov (United States)

    Bongers, Bart C; Werkman, Maarten S; Blokland, Donna; Eijsermans, Maria J; Van der Torre, Patrick; Bartels, Bart; Verschuren, Olaf; Takken, Tim

    2015-05-01

    To determine criterion validity of the pediatric running-based anaerobic sprint test (RAST) as a nonsophisticated field test for evaluating anaerobic performance in healthy children and adolescents. Data from 65 healthy children (28 boys and 37 girls between 6 and 18 years of age, mean ± SD age: 10.0 ± 2.8 years) who completed both the pediatric RAST and the 30-s Wingate anaerobic test (WAnT) on a cycle ergometer in a randomized order were analyzed. Peak power (PP) and mean power (MP) were the primary outcome measures for both tests. There were no significant sex-differences in PP and MP attained at the pediatric RAST and the WAnT. Age was strongly correlated to pediatric RAST and WAnT performance (Spearman's rho values ranging from 0.85 to 0.90, with p RAST performance and WAnT performance for both PP (Spearman's rho: 0.86; p RAST can be used as a valid and nonsophisticated field test for the assessment of anaerobic performance in healthy children and adolescents. For clinical evaluative purposes, we suggest to use MP of the pediatric RAST when assessing glycolytic power in the absence of the WAnT.

  8. BIA Wingate High School WWTF, Fort Wingate, NM: NN0020958

    Science.gov (United States)

    NPDES Permit and Fact Sheet explaining EPA's action under the Clean Water Act to issue NPDES Permit No. NN0020958 to Bureau of Indian Affairs (BIA) Wingate High School Wastewater Treatment Lagoon, Fort Wingate, NM.

  9. A test to assess aerobic and anaerobic parameters during maximal exercise in young girls.

    Science.gov (United States)

    McGawley, Kerry; Leclair, Erwan; Dekerle, Jeanne; Carter, Helen; Williams, Craig A

    2012-05-01

    The Wingate cycle test (WAnT) is a 30-s test commonly used to estimate anaerobic work capacity (AWC). However, the test may be too short to fully deplete anaerobic energy reserves. We hypothesized that a 90-s all-out isokinetic test (ISO_90) would be valid to assess both aerobic and anaerobic capacities in young females. Eight girls (11.9 ± 0.5 y) performed an exhaustive incremental test, a WAnT and an ISO_90. Peak VO2 attained during the ISO_90 was significantly greater than VO2peak. Mean power, end power, fatigue index, total work done and AWC were not significantly different between the WAnT and after 30 s of the 90-s test (i.e., ISO_30). However, 95% limits of agreement showed large variations between the two tests when comparing all anaerobic parameters. It is concluded that an ISO-90 may be a useful test to assess aerobic capacity in young girls. However, since the anaerobic parameters derived from the ISO_30 did not agree with those derived from a traditional WAnT, the validity of using an ISO_90 to assess anaerobic performance and capacity within this population group remains unconfirmed.

  10. Evaluation of anaerobic capacity in soccer players using a maximal shuttle run test

    Directory of Open Access Journals (Sweden)

    Alexandre Gomes de Almeida

    2009-01-01

    Full Text Available http://dx.doi.org/10.5007/1980-0037.2009v11n1p88   The aim of this study was to investigate whether a 300-m shuttle run test predicts anaerobic capacity, expressed as mean power output in the Wingate test, in a group of professional soccer players. Twenty-one soccer players (21 ± 2 years; 76.8 ± 7.0 kg; 179.8 ± 6.7 cm from a first division team of the São Paulo Soccer Federation participated in the study. In the first session, the players were submitted to the Wingate test for the determination of relative peak power output, relative mean power output and fatigue index. In the second session, the players underwent a shuttle run test which consisted of a maximum sprint of 20 m at the highest speed possible until completing a distance of 300 m. The total run time and mean velocity over the 20 m (V20m were recorded. Blood samples were collected before and after the 300-m shuttle run test for the determination of lactate concentration ([LAC]. Pearson’s correlation between the Wingate and 300-m shuttle run test variables showed that only relative mean power output was significantly correlated with total run time (r = - 0.75 and V20m (r = 0.72. [LAC] showed a significant increase (p < 0.05 when comparing the values obtained before (2.1 ± 1.0 mM and after (14.3 ± 2.4 mM the shuttle run test. In conclusion, this study demonstrated that the 300-m shuttle run test can predict anaerobic capacity in professional soccer players.

  11. Accurate assessment of work done and power during a Wingate anaerobic test

    National Research Council Canada - National Science Library

    Franklin, Kathryn L; Davies, Bruce; Baker, Julien S; Gordon, Rae S

    2007-01-01

    ...). The traditional method of determining brake torque fails to take into account rope-brake theory and, as the brake torque is used to determine the moment of inertia of the flywheel, a second error...

  12. Time-of-Day Effects on EMG Parameters During the Wingate Test in Boys

    National Research Council Canada - National Science Library

    Souissi, Hichem; Chtourou, Hamdi; Chaouachi, Anis; Chamari, Karim; Souissi, Nizar; Amri, Mohamed

    2012-01-01

    ... (measurement of muscle power and fatigue) at 07:00 and 17:00-h on separate days. Surface EMG activity was recorded in the Vastus lateralis, rectus femoris and vastus medialis muscles throughout the test and analyzed over a 5-s span...

  13. CAN AEROBIC AND ANAEROBIC POWER BE MEASURED IN A 60-SECOND MAXIMAL TEST?

    Directory of Open Access Journals (Sweden)

    Daniel G. Carey

    2003-12-01

    Full Text Available The primary objective of this study was to assess the efficacy of measuring both aerobic and anaerobic power in a 60-second, maximal effort test. It was hypothesized that oxygen consumption increases rapidly during maximal effort and maximal oxygen consumption (VO2 max may be reached in one minute. Fifteen United States Cycling Federation competitive cyclists performed the following tests: 1 practice 60-second maximal exertion test; 2 standard incremental workload VO2 max test; 3 Wingate anaerobic power test (WAT; 4 VO2 measured during 60-second maximal exertion test (60-SEC; and 5 VO2 measured during 75-second maximal exertion test (75-SEC. All tests were performed on an electrically-braked cycle ergometer. Hydrostatic weighing was performed to determine percent body fat. Peak oxygen consumption values for the 60-SEC (53.4 ml·kg-1·min-1, 92% VO2 max, and 75-SEC (52.6 ml·kg-1·min-1, 91% VO2 max tests were significantly lower than VO2 max (58.1 ml·kg-1·min-1. During the 75-SEC test, there was no significant difference in percentage VO2max from 30 seconds to 75 seconds, demonstrating a plateau effect. There were no significant differences in peak power or relative peak power between the Wingate, 60-SEC, and 75 SEC tests while, as expected, mean power, relative mean power, and fatigue index were significantly different between these tests. Power measures were highly correlated among all three tests. It was concluded that VO2 max was not attained during either the 60-SEC nor 75-SEC tests. Furthermore, high correlations in power output for WAT, 60-SEC, and 75-SEC precludes the necessity for anaerobic tests longer than the 30-second WAT.

  14. Do isokinetic angular velocity and contraction types affect the predictors of different anaerobic power tests?

    Science.gov (United States)

    Yapici, Aysegul; Findikoglu, Gulin; Dundar, Ugur

    2016-04-01

    The purpose of this study was to investigate the most important predictor isokinetic muscle strength determined by different angular velocities and contraction types (i.e. concentric and eccentric) for selected anaerobic power tests in volleyball players. Twenty male and ten female amateur volleyball players participated in this study. Selected anaerobic power tests included Wingate Anaerobic Test (WAnT), squat jump (SJ) and countermovement jump (CMJ). Peak torque values were obtained at 60, 120, 240˚/s for concentric contraction of quadriceps (Qconc) and Hamstring (Hconc) and at 60˚/s for eccentric contraction of quadriceps (Qecc) and Hconc. Moderate to good correlations (r:0.409 to r:0.887) were found between anaerobic tests and isokinetic data including peak torque and total work of both Hconc and Qconc at 60, 120, 240°/s and Qecc at 60°/s (Pstrength of the relation increases with increasing angular velocity. However, both Qecc and Hconc were significant indicators for CMJ and SJ. Training with higher isokinetic angular velocities and with eccentric contraction is desirable in a training program that has a goal of improving anaerobic performance in volleyball players.

  15. Establishing the Test-Retest Reliability & Concurrent Validity for the Repeat Ice Skating Test (RIST) in Adolescent Male Ice Hockey Players

    Science.gov (United States)

    Power, Allan; Faught, Brent E.; Przysucha, Eryk; McPherson, Moira; Montelpare, William

    2012-01-01

    In this study the authors examine the test-retest reliability and concurrent validity of the Repeat Ice Skating Test (RIST). This was an on-ice field anaerobic test that measured average peak power and was validated with 3 anaerobic lab tests: (a) vertical jump, (b) the Margaria-Kalamen stair test, and (c) the Wingate Anaerobic Test. The…

  16. Relationships Between Anaerobic Performance, Field Tests and Game Performance of Sitting Volleyball Players

    Directory of Open Access Journals (Sweden)

    Marszalek Jolanta

    2015-12-01

    Full Text Available The aim of this study was to evaluate relationships between anaerobic performance, field tests, game performance and anthropometric variables of sitting volleyball players. Twenty elite Polish sitting volleyball players were tested using the 30 s Wingate Anaerobic Test for arm crank ergometer and participated in six physical field tests. Heights in position to block and to spike, as well as arm reach were measured. Players were observed during the game on the court in terms of effectiveness of the serve, block, attack, receive and defense. Pearson analysis and the Spearman's rank correlation coefficient were used. The strongest correlations were found between the chest pass test and mean power and peak power (r=.846; p=.001 and r=.708; p=.0005, respectively, and also between the T-test and peak power (r= −.718; p=.001. Mean power correlated with the 3 m test (r= −.540; p=.014, the 5 m test (r= −.592; p=.006, and the T-test (r= −.582; p=.007. Peak power correlated with the 3 m test (r= −.632; p=.003, the 5 m test (r= −.613; p=.004, speed & agility (r= −.552; p=.012 and speed & endurance (r=−.546; p=.013. Significant correlations were observed between anthropometric parameters and anaerobic performance variables (p≤.001, and also between anthropometric parameters and field tests (p≤.05. Game performance and physical fitness of sitting volleyball players depended on their anthropometric variables: reach of arms, the position to block and to spike. The chest pass test could be used as a non-laboratory field test of anaerobic performance of sitting volleyball players.

  17. Relationships Between Anaerobic Performance, Field Tests and Game Performance of Sitting Volleyball Players.

    Science.gov (United States)

    Marszalek, Jolanta; Molik, Bartosz; Gomez, Miguel Angel; Skučas, Kęstutis; Lencse-Mucha, Judit; Rekowski, Witold; Pokvytyte, Vaida; Rutkowska, Izabela; Kaźmierska-Kowalewska, Kalina

    2015-11-22

    The aim of this study was to evaluate relationships between anaerobic performance, field tests, game performance and anthropometric variables of sitting volleyball players. Twenty elite Polish sitting volleyball players were tested using the 30 s Wingate Anaerobic Test for arm crank ergometer and participated in six physical field tests. Heights in position to block and to spike, as well as arm reach were measured. Players were observed during the game on the court in terms of effectiveness of the serve, block, attack, receive and defense. Pearson analysis and the Spearman's rank correlation coefficient were used. The strongest correlations were found between the chest pass test and mean power and peak power (r=.846; p=.001 and r=.708; p=.0005, respectively), and also between the T-test and peak power (r= -.718; p=.001). Mean power correlated with the 3 m test (r= -.540; p=.014), the 5 m test (r= -.592; p=.006), and the T-test (r= -.582; p=.007). Peak power correlated with the 3 m test (r= -.632; p=.003), the 5 m test (r= -.613; p=.004), speed & agility (r= -.552; p=.012) and speed & endurance (r=-.546; p=.013). Significant correlations were observed between anthropometric parameters and anaerobic performance variables (p≤.001), and also between anthropometric parameters and field tests (p≤.05). Game performance and physical fitness of sitting volleyball players depended on their anthropometric variables: reach of arms, the position to block and to spike. The chest pass test could be used as a non-laboratory field test of anaerobic performance of sitting volleyball players.

  18. Anaerobic capacity may not be determined by critical power model in elite table tennis players.

    Science.gov (United States)

    Zagatto, Alessandro M; Papoti, Marcelo; Gobatto, Claudio A

    2008-01-01

    The aim of the present study was to verify the applicability of anaerobic work capacity (AWC) determined from the critical power model in elite table tennis players. Eight male international level table tennis players participated in the study. The tests undertaken were: 1) A critical frequency test used to determinate the anaerobic work capacity; 2) Wingate tests were performed using leg and arm ergometers. AWC corresponded to 99.5 ± 29.1 table tennis balls. AWC was not related to peak (r = -0.25), mean (r = -0.02), relative peak (r = -0.49) or relative mean power (r = 0.01), nor fatigue index (r = -0.52) (Wingate leg ergometer). Similar correlations for peak (r = -0.34), mean (r = -0.04), relative peak (r = -0.49), relative mean power (r = -0.14) and peak blood lactate concentration (r = -0.08) were determined in the Wingate arm ergometer test. Based on these results the AWC determined by a modified critical power test was not a good index for measurement of anaerobic capacity in table tennis players. Key pointsAnaerobic work capacity (AWC) was not good index of anaerobic capacity in table tennis.AWC determined using the table tennis ergometer showed low correlations with the Wingate test measures for cycle and arm ergometry.A sport-specific protocol is required for measuring anaerobic capacity in table tennis.

  19. Effects of Creatine and Sodium Bicarbonate Coingestion on Multiple Indices of Mechanical Power Output During Repeated Wingate Tests in Trained Men.

    Science.gov (United States)

    Griffen, Corbin; Rogerson, David; Ranchordas, Mayur; Ruddock, Alan

    2015-06-01

    This study investigated the effects of creatine and sodium bicarbonate coingestion on mechanical power during repeated sprints. Nine well-trained men (age = 21.6 ± 0.9 yr, stature = 1.82 ± 0.05 m, body mass = 80.1 ±12.8 kg) participated in a double-blind, placebo-controlled, counterbalanced, crossover study using six 10-s repeated Wingate tests. Participants ingested either a placebo (0.5 g·kg(-1) of maltodextrin), 20 g·d(-1) of creatine monohydrate + placebo, 0.3 g·kg(-1) of sodium bicarbonate + placebo, or coingestion + placebo for 7 days, with a 7-day washout between conditions. Participants were randomized into two groups with a differential counterbalanced order. Creatine conditions were ordered first and last. Indices of mechanical power output (W), total work (J) and fatigue index (W·s(-1)) were measured during each test and analyzed using the magnitude of differences between groups in relation to the smallest worthwhile change in performance. Compared with placebo, both creatine (effect size (ES) = 0.37-0.83) and sodium bicarbonate (ES = 0.22-0.46) reported meaningful improvements on indices of mechanical power output. Coingestion provided small meaningful improvements on indices of mechanical power output (W) compared with sodium bicarbonate (ES = 0.28-0.41), but not when compared with creatine (ES = -0.21-0.14). Coingestion provided a small meaningful improvement in total work (J; ES = 0.24) compared with creatine. Fatigue index (W·s(-1)) was impaired in all conditions compared with placebo. In conclusion, there was no meaningful additive effect of creatine and sodium bicarbonate coingestion on mechanical power during repeated sprints.

  20. ANAEROBIC EXERCISE TESTING IN REHABILITATION : A SYSTEMATIC REVIEW OF AVAILABLE TESTS AND PROTOCOLS

    NARCIS (Netherlands)

    Krops, Leonie A.; Albada, Trijntje; van der Woude, Lucas H. V.; Hijmans, Juha M.; Dekker, Rienk

    Objective: Anaerobic capacity assessment in rehabilitation has received increasing scientific attention in recent years. However, anaerobic capacity is not tested consistently in clinical rehabilitation practice. This study reviews tests and protocols for anaerobic capacity in adults with various

  1. Relationship between anaerobic power and jumping of selected male volleyball players of different ages.

    Science.gov (United States)

    Kasabalis, Athanasios; Douda, Helen; Tokmakidis, Savvas P

    2005-06-01

    The aim of the present study was to evaluate the anaerobic power of elite male volleyball players, using the Wingate Anaerobic Test to examine the relationship between anaerobic power and jumping performance. Athletes (n=56) and Nonathletes (n=53) were divided into three age groups: Adults (18-25 yr.), Juniors (15-16 yr.), and Youth (10-11 yr.). Measurements of height, body mass, vertical jump and Wingate scores indicated higher values for athletes. The specific training effects of anaerobic power were more pronounced at the age of 10-11 years than for Nonathletes. A significant correlation coefficient between peak power and vertical jump was found for Athletes (r=.86) and for the total group (r=.82). These results indicated that vertical jump may predict the maximal anaerobic power and could be used by coaches as a practical and easy-to-apply field screening test for evaluation in volleyball training.

  2. Oxidative stress in response to aerobic and anaerobic power testing: influence of exercise training and carnitine supplementation.

    Science.gov (United States)

    Bloomer, Richard J; Smith, Webb A

    2009-01-01

    The purpose of this study is to compare the oxidative stress response to aerobic and anaerobic power testing, and to determine the impact of exercise training with or without glycine propionyl-L-carnitine (GPLC) in attenuating the oxidative stress response. Thirty-two subjects were assigned (double blind) to placebo, GPLC-1 (1g PLC/d), GPLC-3 (3g PLC/d) for 8 weeks, plus aerobic exercise. Aerobic (graded exercise test: GXT) and anaerobic (Wingate cycle) power tests were performed before and following the intervention. Blood was taken before and immediately following exercise tests and analyzed for malondialdehyde (MDA), hydrogen peroxide (H2O2), and xanthine oxidase activity (XO). No interaction effects were noted. MDA was minimally effected by exercise but lower at rest for both GPLC groups following the intervention (p = 0.044). A time main effect was noted for H2O2 (p = 0.05) and XO (p = 0.003), with values increasing from pre- to postexercise. Both aerobic and anaerobic power testing increase oxidative stress to a similar extent. Exercise training plus GPLC can decrease resting MDA, but it has little impact on exercise-induced oxidative stress biomarkers.

  3. The triple-120 meter shuttle test: a sport-specific test for assessing anaerobic endurance fitness in rugby league players.

    Science.gov (United States)

    Holloway, Kate M; Meir, Rudi A; Brooks, Lyndon O; Phillips, Cameron J

    2008-03-01

    The aim of this study was to design a simple field test to measure the anaerobic endurance fitness of rugby league players, which is an important fitness quality in the game of rugby league. Twelve amateur football players with a mean (+/-SD) age of 21.5 years (+/-2.2) volunteered to participate in the study. The subjects completed 1 trial of the Wingate 60-second (W60) cycle test and 2 trials of the new Triple-120 meter shuttle (T120S) test. All trials were completed 4 days apart. The validity of the T120S was determined by comparing physiological responses (heart rate and blood lactate) and rating of perceived exertion to the all-out W60 cycle test. The results indicate there is a significant relationship between maximum heart rate (r = 0.63 and 0.71) for the 2 trials of the T120S and the W60 cycle test. There was no significant relationship between the 2 trials and the W60 cycle test for post 3 minute lactate (r = 0.112 and 0.101) and rating of perceived exertion (r = 0.94 and 0.161). However, the T120S test elicited greater mean values for these measures than the W60 cycle test. The results indicate that the T120S is a valid test of anaerobic endurance and represents a sports specific test of this quality that may provide useful information for players and coaches involved in the sport of rugby league.

  4. [Antimicrobial susceptibility testing of anaerobic bacteria].

    Science.gov (United States)

    García-Sánchez, José E; García-Sánchez, Enrique; García-García, María Inmaculada

    2014-02-01

    The anaerobic bacteria resistance to antibiotics is increasing, and even has appeared against the most active of those, like metronidazol and carbapenems. This fact forces to make and periodical sensibility tests -at least in the most aggressive and virulent species, in cases that they are isolated from life locations and in the absence of therapeutic response- to check the local sensibility and to establish suitable empiric therapies, all based on multicentric studies carried out in order to this or well to check the activity of new antibiotics. For the laboratory routine, the easiest sensibility method is the E-test/MIC evaluator. Another alternative is microdilution, that's only normalized for Bacteroides. There are preliminary facts that allow the use of disc diffusion method in some species of Bacteroides and Clostridium. For the temporal and multicentric studies, the procedure is dilution in agar plate, the reference method. Copyright © 2014 Elsevier España, S.L. All rights reserved.

  5. SLEEP DEPRIVATION INDUCED ANXIETY AND ANAEROBIC PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Selma Arzu Vardar

    2007-12-01

    Full Text Available The aim of this study was to investigate the effects of sleep deprivation induced anxiety on anaerobic performance. Thirteen volunteer male physical education students completed the Turkish version of State Anxiety Inventory and performed Wingate anaerobic test for three times: (1 following a full-night of habitual sleep (baseline measurements, (2 following 30 hours of sleep deprivation, and (3 following partial-night sleep deprivation. Baseline measurements were performed the day before total sleep deprivation. Measurements following partial sleep deprivation were made 2 weeks later than total sleep deprivation measurements. State anxiety was measured prior to each Wingate test. The mean state anxiety following total sleep deprivation was higher than the baseline measurement (44.9 ± 12.9 vs. 27.6 ± 4.2, respectively, p = 0.02 whereas anaerobic performance parameters remained unchanged. Neither anaerobic parameters nor state anxiety levels were affected by one night partial sleep deprivation. Our results suggest that 30 hours continuous wakefulness may increase anxiety level without impairing anaerobic performance, whereas one night of partial sleep deprivation was ineffective on both state anxiety and anaerobic performance

  6. Can a 15m-overground wheelchair sprint be used to assess wheelchair-specific anaerobic work capacity?

    NARCIS (Netherlands)

    van der Scheer, Jan W.; de Groot, Sonja; Vegter, Riemer J. K.; Veeger, DirkJan (H. E. J. ); van der Woude, Lucas H. V.

    OBJECTIVE: To evaluate whether outcomes based on stopwatch time and power output (PO) over a 15m-overground wheelchair sprint test can be used to assess wheelchair-specific anaerobic work capacity, by studying their relationship with outcomes on a Wingate-based 30s-wheelchair ergometer sprint

  7. TEST RESULTS FOR FUEL CELL OPERATION ON ANAEROBIC DIGESTER GAS

    Science.gov (United States)

    EPA, in conjunction with ONSI Corp., embarked on a project to define, design, test, and assess a fuel cell energy recovery system for application at anaerobic digester waste water (sewage) treatment plants. Anaerobic digester gas (ADG) is produced at these plants during the proce...

  8. The Yo-Yo intermittent recovery test level 1 as a high intensity training tool: aerobic and anaerobic responses.

    Science.gov (United States)

    Delahunt, Eamonn; Callan, Louise; Donohoe, Jessica; Melican, Ruth; Holden, Sinéad

    2013-05-01

    The aim of this study was to investigate the effects of using the Yo-Yo intermittent recovery test level 1 (Yo-Yo IR1) as a high intensity training tool for sedentary university female students. Baseline measures were recorded for body fat percentage, Wingate Anaerobic Test (WAnT) peak power and mean power, and Yo-Yo IR1 performance. Subjects were matched in pairs for body fat percentage and then randomly allocated to the intervention group (INT) (n=12) or control group (CON) (n=13). The INT undertook a 6-week training programme twice a week using the Yo-Yo IR1. The CON undertook no training. The INT increased their Yo-Yo IR1 performance (230±38m baseline vs 403±152m post-training), WAnT peak power (970±176 Watts baseline vs 1148±159 Watts post-training), and WAnT mean power (399±55 Watts baseline vs 439±53 Watts post-training) (p0.05). The results of this study show that a 6-week high intensity intermittent training programme using the Yo-Yo IR1 as a training intervention increases both aerobic and anaerobic capacity in a sedentary female population. Copyright © 2013 Elsevier Inc. All rights reserved.

  9. Anaerobic contribution during maximal anaerobic running test: correlation with maximal accumulated oxygen deficit.

    Science.gov (United States)

    Zagatto, A; Redkva, P; Loures, J; Kalva Filho, C; Franco, V; Kaminagakura, E; Papoti, M

    2011-12-01

    The aims of this study were: (i) to measure energy system contributions in maximal anaerobic running test (MART); and (ii) to verify any correlation between MART and maximal accumulated oxygen deficit (MAOD). Eleven members of the armed forces were recruited for this study. Participants performed MART and MAOD, both accomplished on a treadmill. MART consisted of intermittent exercise, 20 s effort with 100 s recovery, after each spell of effort exercise. Energy system contributions by MART were also determined by excess post-exercise oxygen consumption, lactate response, and oxygen uptake measurements. MAOD was determined by five submaximal intensities and one supramaximal intensity exercises corresponding to 120% at maximal oxygen uptake intensity. Energy system contributions were 65.4±1.1% to aerobic; 29.5±1.1% to anaerobic a-lactic; and 5.1±0.5% to anaerobic lactic system throughout the whole test, while only during effort periods the anaerobic contribution corresponded to 73.5±1.0%. Maximal power found in MART corresponded to 111.25±1.33 mL/kg/min but did not significantly correlate with MAOD (4.69±0.30 L and 70.85±4.73 mL/kg). We concluded that the anaerobic a-lactic system is the main energy system in MART efforts and this test did not significantly correlate to MAOD. © 2011 John Wiley & Sons A/S.

  10. A simple and sensitive quality control method of the anaerobic atmosphere for identification and antimicrobial susceptibility testing of anaerobic bacteria

    DEFF Research Database (Denmark)

    Justesen, Tage; Justesen, Ulrik Stenz

    2013-01-01

    The maintenance of a strict anaerobic atmosphere is essential for the culture of strict anaerobic bacteria. We describe a simple and sensitive quality control method of the anaerobic atmosphere, based on the measurement of the zone diameter around a 5-μg metronidazole disk when testing an aerotol...... an aerotolerant Clostridium perfringens strain. A zone diameter above 27 mm was indicative of acceptable anaerobic conditions....

  11. A simple and sensitive quality control method of the anaerobic atmosphere for identification and antimicrobial susceptibility testing of anaerobic bacteria.

    Science.gov (United States)

    Justesen, Tage; Justesen, Ulrik Stenz

    2013-06-01

    The maintenance of a strict anaerobic atmosphere is essential for the culture of strict anaerobic bacteria. We describe a simple and sensitive quality control method of the anaerobic atmosphere, based on the measurement of the zone diameter around a 5-μg metronidazole disk when testing an aerotolerant Clostridium perfringens strain. A zone diameter above 27 mm was indicative of acceptable anaerobic conditions. Copyright © 2013 Elsevier Inc. All rights reserved.

  12. Running-based Anaerobic Sprint Test As A Procedure To Evaluate Anaerobic Power

    OpenAIRE

    Andrade; V. L.; Zagatto; A. M.; Kalva-Filho; C. A.; Mendes; O. C.; Gobatto; C. A.; Campos; E. Z.; Papoti; M.

    2016-01-01

    The aim of this study was to evaluate the use of the running anaerobic sprint test (RAST) as a predictor of anaerobic capacity, compare it to the maximal accumulated oxygen deficit (MAOD) and to compare the RAST's parameters with the parameters of 30-s all-out tethered running on a treadmill. 39 (17.0+/-1.4 years) soccer players participated in this study. The participants underwent an incremental test, 10 submaximal efforts [50-95% of velocity correspondent to VO2MAX (vVO(2MAX))] and one sup...

  13. Running-based Anaerobic Sprint Test as a Procedure to Evaluate Anaerobic Power.

    Science.gov (United States)

    Andrade, V L; Zagatto, A M; Kalva-Filho, C A; Mendes, O C; Gobatto, C A; Campos, E Z; Papoti, M

    2015-12-01

    The aim of this study was to evaluate the use of the running anaerobic sprint test (RAST) as a predictor of anaerobic capacity, compare it to the maximal accumulated oxygen deficit (MAOD) and to compare the RAST's parameters with the parameters of 30-s all-out tethered running on a treadmill. 39 (17.0±1.4 years) soccer players participated in this study. The participants underwent an incremental test, 10 submaximal efforts [50-95% of velocity correspondent to VO(2MAX) (vVO(2MAX))] and one supramaximal effort at 110% of vVO(2MAX) for the determination of MAOD. Furthermore, the athletes performed the RAST. In the second stage the 30-s all-out tethered running was performed on a treadmill (30-s all-out), and compared with RAST. No significant correlation was observed between MAOD and RAST parameters. However, significant correlations were found between the power of the fifth effort (P5) of RAST with peak and mean power of 30-s all-out (r=0.73 and 0.50; pRAST do not have an association with MAOD, suggesting that this method should not be used to evaluate anaerobic capacity. Although the correlations between RAST parameters with 30-s all-out do reinforce the RAST as an evaluation method of anaerobic metabolism, such as anaerobic power. © Georg Thieme Verlag KG Stuttgart · New York.

  14. Evaluation of the running-based anaerobic sprint test as a measure of repeated sprint ability in collegiate-level soccer players.

    Science.gov (United States)

    Keir, Daniel A; Thériault, Francis; Serresse, Olivier

    2013-06-01

    Repeated sprint ability (RSA) refers to an individual's ability to perform maximal sprints of short duration in succession with little recovery between sprints. The running-based anaerobic sprint test (RAST) has been adapted from the Wingate anaerobic test (WAnT) protocol as a tool to assess RSA and anaerobic power. The purpose of this study was to evaluate the relationship between performance variables and physiological responses obtained during the RAST and the WAnT using 8 collegiate-level soccer players. Participants performed a single trial of both the WAnT and the RAST. Breath-by-breath gas exchange was monitored throughout each trial, and blood lactate (BL) measures were recorded postexercise. The oxygen uptake (VO2) profile suggested that the RAST required greater contributions from aerobic metabolism although there was no difference in VO2peak (p RAST and the WAnT (p test are not related in collegiate soccer players. Further studies on these relationships with players of other competitive levels and team sport athletes are warranted.

  15. The effect of pre-exercise carbohydrate supplementation on anaerobic exercise performance in adolescent males.

    Science.gov (United States)

    Lee, Jonah D; Sterrett, Lauren E; Guth, Lisa M; Konopka, Adam R; Mahon, Anthony D

    2011-08-01

    Carbohydrate (CHO) consumption before anaerobic exercise was studied in 13 adolescent boys (15.2 ± 0.9 yrs). A within subjects design was employed where subjects consumed a 22% CHO or volume-matched placebo (PL) beverage 30-min before anaerobic exercise on two separate days. Exercise consisted of a Wingate Anaerobic Test (WAnT), ten by 10-s-sprints, and a second WAnT. Fatigue index and peak power (PP) were similar while mean power (MP) was higher (p exercise; however, this strategy did not attenuate fatigue over time in adolescent boys.

  16. ANAEROBIC CAPACITY MAY NOT BE DETERMINED BY CRITICAL POWER MODEL IN ELITE TABLE TENNIS PLAYERS

    Directory of Open Access Journals (Sweden)

    Alessandro M. Zagatto

    2008-03-01

    Full Text Available The aim of the present study was to verify the applicability of anaerobic work capacity (AWC determined from the critical power model in elite table tennis players. Eight male international level table tennis players participated in the study. The tests undertaken were: 1 A critical frequency test used to determinate the anaerobic work capacity; 2 Wingate tests were performed using leg and arm ergometers. AWC corresponded to 99.5 ± 29.1 table tennis balls. AWC was not related to peak (r = -0.25, mean (r = -0.02, relative peak (r = -0.49 or relative mean power (r = 0.01, nor fatigue index (r = -0.52 (Wingate leg ergometer. Similar correlations for peak (r = -0.34, mean (r = -0.04, relative peak (r = -0.49, relative mean power (r = -0.14 and peak blood lactate concentration (r = -0.08 were determined in the Wingate arm ergometer test. Based on these results the AWC determined by a modified critical power test was not a good index for measurement of anaerobic capacity in table tennis players

  17. Anaerobic

    Science.gov (United States)

    ... them during shorter, more intense activities like sprinting. Anaerobic exercise leads to a buildup of lactic acid in ... Asplund CA, Best TM. Exercise physiology. In: Miller MD, Thompson ... Douglas, and Bennett's Principles and Practice of Infectious ...

  18. Validity of the Pediatric Running-Based Anaerobic Sprint Test to Determine Anaerobic Performance in Healthy Children

    NARCIS (Netherlands)

    Bongers, Bart C.; Werkman, Maarten S.; Blokland, Donna; Eijsermans, Maria J. C.; van der Torre, Patrick; Bartels, Bart; Verschuren, Olaf; Takken, Tim

    Purpose: To determine criterion validity of the pediatric running-based anaerobic sprint test (RAST) as a nonsophisticated field test for evaluating anaerobic performance in healthy children and adolescents. Methods: Data from 65. healthy children (28 boys and 37 girls between 6 and 18 years of age,

  19. Motivation and motoric tests in sports.

    Science.gov (United States)

    Karaba-Jakovljević, Dea; Popadić-Gaćesa, Jelena; Grujić, Nikola; Barak, Otto; Drapsin, Miodrag

    2007-01-01

    Motivation in sport performance has been an interesting topic for many investigators during the past decade. This area can be considered from different viewpoints: motivation for participation in sport activity, achievement motivation, competitiveness etc. Motivation plays an important role in all out tests, as well as in sport activities and at all levels of competition. Motivation climate, or positive social environment may influence and modulate motivation of individuals involved in sports. Experience has shown that conventional encouragement and feedback during the test may affect its outcome. According to Wingate research team recommendations, verbal encouragement, as a motivation factor, was given to all examined subjects during Wingate anaerobic test, which is considered the most reliable test for assessing anaerobic capacity. The investigated group consisted of 30 young men--medical students, who were not actively involved in any programmed sport activity. The investigated group included second-year students of the Faculty of Medicine in Novi Sad chosen by random sampling. The Wingate anaerobic test was performed in all subjects, and changes of parameters when test was performed with verbal encouragement, were recorded The results show statistically significant increase of Wingate test parameters when conducted with verbal encouragement: anaerobic power (622/669 W); relative anaerobic power (7.70/8.27 W/kg); slope of the power (95.5/114 W/s); relative slope of the power (1.18/1.40 W/s/kg); anaerobic capacity (12.7/13.2 kJ) and relative anaerobic capacity (158/164 J/kg).

  20. EFFECT OF MUSIC ON ANAEROBIC EXERCISE PERFORMANCE

    Science.gov (United States)

    2013-01-01

    For years, mostly the effects of music on cardiorespiratory exercise performance have been studied, but a few studies have examined the effect of music on anaerobic exercise. The purpose of this study was to assess the effect of listening to music and its rhythm on anaerobic exercise: on power output, heart rate and the concentration of blood lactate. 28 male subjects were required to visit the laboratory on 6 occasions, each separated by 48 hours. Firstly, each subject performed the Running-based Anaerobic Sprint Test (RAST) under 3 conditions on separate days: while listening to “slow rhythm music”, “fast rhythm music” or “no music”. 48 hours after the subjects completed RAST under 3 conditions, Wingate Anaerobic Power (WAN) tests were performed under 3 music conditions. The order of the 3 conditions (slow music, fast music and no music) was selected randomly to prevent an order effect. Results showed no significant differences between 3 conditions in anaerobic power assessments, heart rate or blood lactate (p > 0.05). On the basis of these results it can be said that music cannot improve anaerobic performance. The type of music had no impact on power outputs during RAST and WAN exercise. As a conclusion, listening to music and its rhythm cannot enhance anaerobic performance and cannot change the physiological response to supramaximal exercise. PMID:24744463

  1. Effect of music on anaerobic exercise performance.

    Science.gov (United States)

    Atan, T

    2013-03-01

    For years, mostly the effects of music on cardiorespiratory exercise performance have been studied, but a few studies have examined the effect of music on anaerobic exercise. The purpose of this study was to assess the effect of listening to music and its rhythm on anaerobic exercise: on power output, heart rate and the concentration of blood lactate. 28 male subjects were required to visit the laboratory on 6 occasions, each separated by 48 hours. Firstly, each subject performed the Running-based Anaerobic Sprint Test (RAST) under 3 conditions on separate days: while listening to "slow rhythm music", "fast rhythm music" or "no music". 48 hours after the subjects completed RAST under 3 conditions, Wingate Anaerobic Power (WAN) tests were performed under 3 music conditions. The order of the 3 conditions (slow music, fast music and no music) was selected randomly to prevent an order effect. Results showed no significant differences between 3 conditions in anaerobic power assessments, heart rate or blood lactate (p > 0.05). On the basis of these results it can be said that music cannot improve anaerobic performance. The type of music had no impact on power outputs during RAST and WAN exercise. As a conclusion, listening to music and its rhythm cannot enhance anaerobic performance and cannot change the physiological response to supramaximal exercise.

  2. EFFECT OF MUSIC ON ANAEROBIC EXERCISE PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Tülin Atan

    2013-01-01

    Full Text Available For years, mostly the effects of music on cardiorespiratory exercise performance have been studied, but a few studies have examined the effect of music on anaerobic exercise. The purpose of this study was to assess the effect of listening to music and its rhythm on anaerobic exercise: on power output, heart rate and the concentration of blood lactate. 28 male subjects were required to visit the laboratory on 6 occasions, each separated by 48 hours. Firstly, each subject performed the Running-based Anaerobic Sprint Test (RAST under 3 conditions on separate days: while listening to “slow rhythm music”, “fast rhythm music” or “no music”. 48 hours after the subjects completed RAST under 3 conditions, Wingate Anaerobic Power (WAN tests were performed under 3 music conditions. The order of the 3 conditions (slow music, fast music and no music was selected randomly to prevent an order effect. Results showed no significant differences between 3 conditions in anaerobic power assessments, heart rate or blood lactate (p>0.05. On the basis of these results it can be said that music cannot improve anaerobic performance. The type of music had no impact on power outputs during RAST and WAN exercise. As a conclusion, listening to music and its rhythm cannot enhance anaerobic performance and cannot change the physiological response to supramaximal exercise.

  3. PENGELOLAAN JARINGAN INTERNET DENGAN PROXY WINGATE

    Directory of Open Access Journals (Sweden)

    Titin Winarti

    2005-01-01

    Full Text Available Proxy adalah bagian dari protokol yang berfungsi sebagai link untuk host tunggal atau sebagai link untuk beberapa host antarajaringan dan jaringan lain. Proxy wingate adalah software yang digunakan untuk berbagi koneksi internet melalui satu alamat IPyang terintegrasi ke internet.

  4. Anaerobic fitness assessment in taekwondo athletes. A new perspective

    Directory of Open Access Journals (Sweden)

    Fernando Rocha

    2016-10-01

    Full Text Available We intended to determine the concurrent validity of a taekwondo specific anaerobic test (TSAT to assess anaerobic fitness in taekwondo athletes. Seventeen elite male subjects (17.59 ± 4.34 years of age; 1.72 m ± .07 m in height; 61.3 kg ± 8.7 kg in weight and 15.6% ± 8.5% in body fat performed a TSAT, which consisted of kicking a punching bag for 30 seconds. The standard test was the Wingate Anaerobic Test. Two trials were made for both tests and the agreement between both was tested. The variables analysed and compared were: peak power; relative peak power; mean anaerobic power; relative mean anaerobic power; fatigue index and anaerobic capacity. The number of kicks performed in the TSAT protocol and the maximum height of the counter movement jump (CMJ were also registered. Trial I and II had significant ICC results in all variables (P = .000 ranged between 0.56 and 0.97. Both protocols were significantly correlated (r = 0.55 to 0.88; P = .000 to .05. CMJ strongly correlated with the number of techniques (r=0.59; P = .013 and the mean power (r = 0.56; P = .019 of the TSAT. The variables between the two methods correlate and are consistent, except for the anaerobic capacity that although correlated, is not consistent with constant bias, P = 0.001; CI]-705.1;-370.2[. TSAT has a level of agreement with the Wingate, and assigns specificity in the evaluation of these variables.

  5. Investigating the effects of maximal anaerobic fatigue on dynamic postural control using the Y-Balance Test.

    Science.gov (United States)

    Johnston, William; Dolan, Kara; Reid, Niamh; Coughlan, Garrett F; Caulfield, Brian

    2017-06-08

    The Y Balance Test is one of the most commonly used dynamic balance assessments, providing an insight into the integration of the sensorimotor subsystems. In recent times, there has been an increase in interest surrounding it's use in various clinical populations demonstrating alterations in motor function. Therefore, it is important to examine the effect physiological influences such as fatigue play in dynamic postural control, and establish a timeframe for its recovery. Descriptive laboratory study. Twenty male and female (age 23.75±4.79years, height 174.12±8.45cm, mass 69.32±8.76kg) partaking in competitive sport, completed the Y Balance Test protocol at 0, 10 and 20min, prior to a modified 60s Wingate fatiguing protocol. Post-fatigue assessments were then completed at 0, 10 and 20 min post-fatiguing intervention. Intraclass correlation coefficients demonstrated excellent intra-session reliability (0.976-0.982) across the three pre-fatigue YBT tests. Post-hoc paired sample t-tests demonstrated that all three reach directions demonstrated statistically significant differences between pre-fatigue and the first post-fatigue measurement (anterior; p=0.019, posteromedial; p=0.019 & posterolateral; p=0.003). The anterior reach direction returned to pre-fatigue levels within 10min (p=0.632). The posteromedial reach direction returned to pre-fatigue levels within 20min (p=0.236), while the posterolateral direction maintained a statistically significant difference at 20min (p=0.023). Maximal anaerobic fatigue has a negative effect on normalised Y balance test scores in all three directions. Following the fatiguing protocol, dynamic postural control returns to pre-fatigue levels for the anterior (20min). Copyright © 2017 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  6. Specific methanogenic activity test for anaerobic degradation of influents

    Science.gov (United States)

    Hussain, Athar; Dubey, Shashi Kant

    2017-05-01

    Specific methanogenic activity (SMA) determines the methane-producing capability of the sludge for a specific substrate. Methanogenic activity test can be used to delineate the operating conditions for anaerobic systems and a parameter to assess the system performance by giving a better perceptive of the system and its stability. At the beginning of the start-up period of a new digester, the SMA is of great importance for the determination of proper initial organic loading rate. In different phases, a regular determination of SMA also ascertains the development stages of the sludge. Also, a change in SMA indicates an inhibition or an accumulation of slow degradable or even non-biodegradable organic matter from the influents. This paper reviews the SMA of anaerobic sludge under different operating conditions using different substrates.

  7. Influence of two high-intensity intermittent training programmes on anaerobic capacity in humans

    Directory of Open Access Journals (Sweden)

    K Buśko

    2011-03-01

    Full Text Available The aim of this work was to determine the influence of a maximal effort training programme with variation of the pedalling rate on the anaerobic capacity, post-exercise maximal concentration of lactic acid (LA and acid-alkali balance changes in the capillary blood. Identification of the dependence between the lactic acid concentration and the anaerobic capacity produced in the Wingate test was also the goal. The hypothesis that cycloergometer training consisting of maximal efforts with a load equal to 10% of body weight (BW will elicit bigger changes of measured values in comparison to training with a load of 5% BW was verified. Twenty non-athletes, students of UPE took part in the study. They were divided into 2 groups. The first group (M10; n=9 performed maximal efforts with a load equal to 10% of body weight (BW. The second group (M5; n=11 performed maximal efforts with a load of 5% BW. Control measurements of anaerobic capacity (Wingate test were taken every Monday: before the test (0, during 4 weeks of training (1-4 and for 2 weeks after the test (5-6. Blood for the determination of lactic acid concentration and acid-alkali balance was taken from the fingertip before performing the Wingate test – in the 5th, 7th, 9th and 30th resting minute. Changes of maximal power (Pmax were not statistically significant in either group. Significant differences were found between the two groups after the second week of rest. For mean power (Pm the most important changes were noted in the first week from training (M10 – 6.5%; M5 – 11.0% No significant differences were found between groups. Average values of the individual LA concentration peak (the highest LA concentration occurring after the Wingate test for each individual changed significantly in group M10 from 15.233±2.367 mmol/l in the measurement made before training to 12.340±2.353 mmol/l in the measurement taken 2 weeks after training. Group M5 is characterised by a change of this factor

  8. Neural adaptations after short-term wingate-based high-intensity interval training

    Science.gov (United States)

    Vera-Ibañez, Antonio; Colomer-Poveda, David; Romero-Arenas, Salvador; Viñuela-García, Manuel; Márquez, Gonzalo

    2017-01-01

    Objectives: This study examined the neural adaptations associated with a low-volume Wingate-based High Intensity Interval Training (HIIT). Methods: Fourteen recreationally trained males were divided into an experimental (HIIT) and a control group to determine whether a short-term (4 weeks) Wingate-based HIIT program could alter the Hoffmann (H-) reflex, volitional (V-) wave and maximum voluntary contraction (MVC) of the plantar-flexor muscles, and the peak power achieved during a Wingate test. Results: Absolute and relative peak power increased in the HIIT group (ABS_Ppeak: +14.7%, P=0.001; and REL_Ppeak: +15.0%, P=0.001), but not in the control group (ABS_Ppeak: P=0.466; and REL_Ppeak: P=0.493). However, no significant changes were found in the MVC (P>0.05 for both groups). There was a significant increase in H-reflex size after HIIT (+24.5%, P=0.004), while it remained unchanged in the control group (P=0.134). No significant changes were observed either in the V-wave or in the Vwave/Mwave ratio (P>0.05 for both groups). Conclusion: The Wingate-based training led to an increased peak power together with a higher spinal excitability. However, no changes were found either in the volitional wave or in the MVC, indicating a lack of adaptation in the central motor drive. PMID:29199186

  9. Intermediate and long-term anaerobic performance of elite Alpine skiers.

    Science.gov (United States)

    Bacharach, D W; von Duvillard, S P

    1995-03-01

    Physiological requirements of Alpine skiing, demanding power from both aerobic and anaerobic sources, were first reported in 1965 by Bengt Saltin and coworkers. An update on the physiology of Alpine skiing was presented by Karlsson and colleagues in 1978, and their work remains a benchmark for most current research dealing with Alpine skiers. These works have identified muscular strength and complex motor skill abilities as essential to the competitive ski racer. The energy demands of Alpine ski racing dominate the range between 45 and 2 min. Since the late 1970s, many researchers have reported a variety of tests that associate test scores to skiing performance. Traditionally, short tests of anaerobic power such as the 30-s Wingate test have been used to reflect anaerobic capacity. Only recently have researchers and coaches begun to question whether a test that is shorter in duration than most skiing performances can estimate anaerobic power as it relates to Alpine ski racing. This study reviews current literature relative to physiological requirements for Alpine skiing as well as relating 18 nationally ranked male (N = 10) and female (N = 8) Alpine ski racers' USSA national points lists for slalom and giant slalom to power measures from 30-s and 90-s Wingate cycle ergometer tests. Further directions of physiological research in Alpine skiing are also offered.

  10. Development and assessment of the Monark cycle ergometer for anaerobic muscular exercise

    Science.gov (United States)

    Frederick, F. A.; Langevin, R. C.; Miletti, J.; Sacco, M.; Murphy, M. M.

    1983-07-01

    This report describes the system developed by this Institute to measure anaerobic power production using the protocol developed at the Wingate Institute in Israel. This test consists of 30 seconds of maximal cycling (or cranking) exercise against a resistance determined according to the body weight of the subject. The system consists of a modified Monark cycle ergometer, a universal counter to monitor flywheel revolutions, and a desktop computer for timing, control, and data processing. The modification of the ergometer for the instantaneous application of resistance is presented. In addition, the methods used to measure pedal revolutions and to calibrate the ergometer, and the analysis of the forces acting on the flywheel are described. Finally, a description of the procedure used in the performance of the Wingate test and a summary of the actual data output are presented.

  11. Effects of sleep deprivation on anaerobic exercise-induced changes in auditory brainstem evoked potentials.

    Science.gov (United States)

    Oztürk, Levent; Bulut, Erdoğan; Vardar, Selma Arzu; Uzun, Cem

    2007-09-01

    The present study was designed to assess how anaerobic exercise affects auditory brainstem response (ABR) parameters, and whether one night of sleep deprivation could alter these possible exercise-induced changes in ABRs. Seven healthy, audiologically normal male students (mean age 22.4 +/- 1.0 years) participated in the study. All subjects underwent anaerobic Wingate test for three times: (i) baseline, (ii) following a full-night of habitual sleep and (iii) following one night of sleep deprivation. ABR measurements were performed before and after the second and the third Wingate tests. Oral body temperatures were recorded at the beginning of all ABR measurements. The latencies of wave III and V significantly shortened by anaerobic loading performed in the day after habitual sleep (4.13 +/- 0.10 versus 4.01 +/- 0.17 ms, Pexercise latencies and altered exercise-induced changes in ABRs. The findings obtained in the present study show that acute anaerobic exercise is effective on ABR wave latencies independent from body temperature changes, and sleep deprivation has some modulatory effects on exercise-induced changes in ABR.

  12. The Effect of Passive versus Active Recovery on Power Output over Six Repeated Wingate Sprints

    Science.gov (United States)

    Lopez, Egla-Irina D.; Smoliga, James M.; Zavorsky, Gerald S.

    2014-01-01

    Purpose: The aim of this study was to examine the effect of active versus passive recovery on 6 repeated Wingate tests (30-s all-out cycling sprints on a Velotron ergometer). Method: Fifteen healthy participants aged 29 (SD = 8) years old (body mass index = 23 [3] kg/m[superscript 2]) participated in 3 sprint interval training sessions separated…

  13. Reproducibility of Running Anaerobic Sprint Test for soccer players.

    Science.gov (United States)

    De Andrade, Vitor L; Santiago, Paul R Pereira; Kalva Filho, Carlos A; Campos, Eduardo Zapaterra; Papoti, Marcelo

    2016-01-01

    Although the Running Anaerobic Sprint Test (RAST) presents reliability when performed on firmer surfaces (i.e. athletic track), its application on less rigid surfaces can compromise the measure determinations. Thus, the aim of the present study was to evaluate the RAST reliability for soccer players performing on grass, and wearing soccer cleats. Fourteen soccer players (16±1 years, 72.3±10.3 kg, 177.2±8.4 cm, 14.5±5.3% of fat mass, and VO2MAX of 52.0±5.1 mL∙kg-1∙min-1) performed six maximal 35-meter effort interspersed by 10s of passive rest (RAST). After 48h the RAST was repeated to test the reliability. The main variables analyzed were the peak power (PP), mean power (MP), fatigue indexes (FI), and impulse (ImP). The reproducibility of test and re-test was tested through the Student's t Test to paired samples, intraclass correlation (ICC), typical error (TE), and coefficient of variation (CV%). The PP (test=701.4±169.5 W; re-test 712.4±142.3 W), MP (test=538.6±111.4 W; re-test=551.9±101.1 W), and the ImP (test=2841.2±461.8 N∙s; re-test=2797.2±575.9 N∙s) were not different, presented significant correlation between the situations (ICC=0.88; 0.96 e 0.93; respectively), and low values of TE (71.9 W; 30.6 W e 191.1 N∙s, respectively) and CV% (10.2%; 5.9% e 6.8%, respectively). The FI (test=40.1±5.8; re-test=38.7±7.7%) were not significantly related between the test and re-test, and presented high TE (5.7%) and CV% (14.4%). We can conclude that RAST presents high reliability when performed on grass with soccer cleats, just as rigid surfaces. Besides, the ImP is more robust than the.

  14. Test-retest reliability and criterion validity of a new Taekwondo anaerobic intermittent kick test.

    Science.gov (United States)

    Tayech, Amel; Mejri, Mohamed A; Chaabene, Helmi; Chaouachi, Mehdi; Behm, David G; Chaouachi, Anis

    2018-01-04

    The aim of this study was to determine the relative and absolute test-retest reliability and criterion validity of a new Taekwondo anaerobic intermittent kick test (TAIKT). Twenty Tunisian elite Taekwondo athletes participated in this study (15 males and 5 females). Participants performed the TAIKT and the Running-based Anaerobic Sprint Test (RAST), twice (test and retest), on separate occasions three-week apart. Peak heart rate (HRpeak), blood lactate concentration [La־], and rating of perceived exertion (RPE) were measured during each session. There was no significant difference between the test and retest of TAIKT and RAST for all performances and physiological variables, except for the absolute mean power (Pmean) of RAST. Test-retest results showed that the TAIKT and RAST were reliable. All TAIKT and RAST parameters had an ICC>0.90, SEMRAST parameters (Ppeak (r=0.81; r=0.70), Pmean (r=0.72; r=0.60) in (W and W·Kg-67 respectively), fatigue index (r=0.81), [La־] (r=0.89) and RPE (r=0.78) at Ptest for assessing anaerobic power of Taekwondo athletes.

  15. Lactacidemic variation and movement patterns during anaerobic power test.

    Science.gov (United States)

    de Andrade, Vitor L; Papoti, Marcelo; Zapaterra Campos, Eduardo; Kalva-Filho, Carlos A; Bucken Gobbi, Ronaldo; Palucci Vieira, Luiz H; Souza Bedo, Bruno; Pereira Santiago, Paulo R

    2017-04-28

    After the Running Anaerobic Sprint Test (RAST) high blood lactate concentrations ([La-]) are found. However, no study verified the behavior of this metabolite during RAST. For this, the aim of the present study was to verify the implications of increase [La-] on movement patterns' in RAST performance. Six healthy and active individuals (21.8 ± 3.1 years, 70.9 ± 10.8 kg and 179.7 ± 3.3 cm) executed a standardized warm-up. Two minutes after, subjects performed RAST composed of six maximal 35 m bouts separated by 10 s of passive recovery. During RAST, 14 cameras monitored the subjects to determine tridimensional and bi-dimensional mechanics. [La-] were determined before warm- up, between each bout and after RAST. Significant difference in performance were found after the fifth (5.1 ± 0.1 s) and sixth (5.4 ± 0.3 s; pRAST performance can be influenced by physiological changes. Biomechanical behavior doesn't alter performance without a sum of physiological events.

  16. Off-Ice Anaerobic Power Does Not Predict On-Ice Repeated Shift Performance in Hockey.

    Science.gov (United States)

    Peterson, Ben J; Fitzgerald, John S; Dietz, Calvin C; Ziegler, Kevin S; Baker, Sarah E; Snyder, Eric M

    2016-09-01

    Peterson, BJ, Fitzgerald, JS, Dietz, CC, Ziegler, KS, Baker, SE, and Snyder, EM. Off-ice anaerobic power does not predict on-ice repeated shift performance in hockey. J Strength Cond Res 30(9): 2375-2381, 2016-Anaerobic power is a significant predictor of acceleration and top speed in team sport athletes. Historically, these findings have been applied to ice hockey although recent research has brought their validity for this sport into question. As ice hockey emphasizes the ability to repeatedly produce power, single bout anaerobic power tests should be examined to determine their ability to predict on-ice performance. We tested whether conventional off-ice anaerobic power tests could predict on-ice acceleration, top speed, and repeated shift performance. Forty-five hockey players, aged 18-24 years, completed anthropometric, off-ice, and on-ice tests. Anthropometric and off-ice testing included height, weight, body composition, vertical jump, and Wingate tests. On-ice testing consisted of acceleration, top speed, and repeated shift fatigue tests. Vertical jump (VJ) (r = -0.42; r = -0.58), Wingate relative peak power (WRPP) (r = -0.32; r = -0.43), and relative mean power (WRMP) (r = -0.34; r = -0.48) were significantly correlated (p ≤ 0.05) to on-ice acceleration and top speed, respectively. Conversely, none of the off-ice tests correlated with on-ice repeated shift performance, as measured by first gate, second gate, or total course fatigue; VJ (r = 0.06; r = 0.13; r = 0.09), WRPP (r = 0.06; r = 0.14; r = 0.10), or WRMP (r = -0.10; r = -0.01; r = -0.01). Although conventional off-ice anaerobic power tests predict single bout on-ice acceleration and top speed, they neither predict the repeated shift ability of the player, nor are good markers for performance in ice hockey.

  17. Effects of different doses of caffeine on anaerobic exercise in boys.

    Science.gov (United States)

    Turley, Ken; Eusse, Paola A; Thomas, Myles M; Townsend, Jeremy R; Morton, Aaron B

    2015-02-01

    This study investigated effects of low (1 mg·kg-1), moderate (3 mg·kg-1) and high (5 mg·kg-1) doses of caffeine on anaerobic performance in boys. Twenty-six 8- to 10-year-old boys participated in a double-blind, crossover, counter-balanced study. Boys received in random order a placebo (PL) or anhydrous caffeine: 1 (CAF-1), 3 (CAF-3), or 5 (CAF-5) mg caffeine·kg-1 body mass in cherry flavored Sprite. Sixty minutes following consumption boys performed a static handgrip test and then a 30-s Wingate test. Maximal grip strength (21.5 ± 4.9 & 21.6 ± 4.7 vs. 20.4 ± 4.0 kg) was significantly higher in CAF-5 & CAF-3 vs PL, respectively. Absolute and relative peak power (287 ± 72 vs 281 ± 69 W & 8.0 ± 0.9 vs 7.8 ± 1.0 W·kg-1) were significantly higher in CAF-3 vs PL, respectively. Mean power (153 ± 48 vs 146 ± 43 W) was significantly higher in CAF-5 vs PL, respectively. Peak Wingate HR was significantly higher (189 ± 8 vs 185 ± 9 beats·min-1) in CAF-5 vs PL, respectively. These findings suggest that in boys CAF-1 did not affect performance. During the Wingate test CAF-3 resulted in higher peak power while CAF-5 increased mean power. The significant increase in peak HR following the Wingate test is likely related to greater mean power generated during CAF-5.

  18. Influence of warm-up duration and recovery interval prior to exercise on anaerobic performance.

    Science.gov (United States)

    Frikha, M; Chaâri, N; Mezghanni, N; Souissi, N

    2016-12-01

    The purpose of the study was to determine the impact of different active warm-up (AWU) durations and the rest interval separating it from exercise on anaerobic performance. Eleven male physical education students (22.6 ± 2.52 years; 179.2 ± 4.3 cm; 82.5 ± 9.7 kg; mean ± SD) participated in a cross-over randomized study, and they all underwent the Wingate test after three AWU durations: 5 min (AWU5), 15 min (AWU15) and 20 min (AWU20), with recovery (WREC) or without a recovery interval (NREC) separating the AWU and anaerobic exercise performance. All the AWUs consisted of pedalling at a constant pace of 60 rpm at 50% of the maximal aerobic power. The rest interval between the end of warm-up and the beginning of exercise was set at 5 min. During the Wingate test, peak power (PP), mean power (MP) and the fatigue index (FI) were recorded and analysed. Oral temperature was recorded at rest and at the end of the warm-up. Likewise, rest, post-warm-up and post-Wingate heart rate (HR) and rating of perceived exertion (RPE) were recorded during each session. The ANOVA showed a significant effect of recovery interval, warm-up duration and measurement point on RPE scores (P0.05). Moreover, the analyses showed a significant interaction between recovery interval and AWU duration (Pexercise of 5 min. However, the AWU5 duration allows better improvement of power output when the exercise is applied immediately after the warm-up. Consequently, physically active males, as well as educators and researchers interested in anaerobic exercise, must take into account the duration of warm-up and the following recovery interval when practising or assessing activities requiring powerful lower limb muscle contractions.

  19. Characterization and BMP Tests of Liquid Substrates for High-rate Anaerobic Digestion

    Directory of Open Access Journals (Sweden)

    M. Mainardis

    2018-01-01

    Full Text Available This work was focused on the physicochemical characterization and biochemical methane potential (BMP tests of some liquid organic substrates, to verify if they were suitable for undergoing a process of high-velocity anaerobic digestion. The selected substrates were: first and second cheese whey, organic fraction of municipal solid waste (OFMSW leachate, condensate water and slaughterhouse liquid waste. Firstly, a physicochemical characterization was performed, using traditional and macromolecular parameters; then, batch anaerobic tests were carried out, and some continuous tests were planned. The results revealed that all the analyzed substrates have a potential to be anaerobically treated. Valuable information about treatment rate for a high-velocity anaerobic digestion process was obtained. Start-up of a lab-scale UASB reactor, treating diluted cheese whey, was successfully achieved with good COD removal efficiency. These preliminary results are expected to be further investigated in a successive phase, where continuous tests will be conducted on condensate water and OFMSW leachate.

  20. Cardiovascular changes during the performance by nonathletes of Bosco repeated jumps anaerobic test

    National Research Council Canada - National Science Library

    Poderys, Jonas; Grūnovas, Albinas; Poderienė, Kristina; Buliuolis, Alfonsas; Šilinskas, Viktoras; Trinkūnas, Eugenijus

    2015-01-01

    Objective: The aim of this study was to find out the characteristics of cardiovascular changes when performing Bosco repeated jumps anaerobic test depending on the duration of jumping in a nonathletes cohort...

  1. Anaerobic Capacity of Sailors with Disabilities

    Directory of Open Access Journals (Sweden)

    Prokopowicz Grzegorz

    2017-03-01

    Full Text Available Introduction. A review of Polish and international literature does not give a clear indication of the level of anaerobic capacity that sailors with disabilities demonstrate with regard to their functional capacities. This study sought to determine differences in functional capacity levels between sailors from three medical and functional groups. Material and methods. The research was carried out during a sports camp at the National Sailing Centre in Górki Zachodnie in 2014. Eighteen males with locomotor disabilities were included in the study. The athletes were members of the National Team of Sailors with Disabilities of the Polish Yachting Association. The sportsmen competed in the Skud 18 and 2.4mR Paralympic classes. A 30-second Wingate test for upper limbs was employed in the study. Results. Significant differences in mean power (MP values were noted between the groups under investigation. The group of wheelchair sailors with improper core stability (A and the group of wheelchair sailors with proper core stability (B had significantly lower scores than the group of study participants who were able to move freely, that is to walk (C. Conclusions. The study revealed that a 30-second anaerobic capacity test performed on an arm ergometer differentiated disabled sailors from selected groups in terms of mean power. Research on anaerobic capacity may be used to verify the current classification in Paralympic sailing and will make it possible to differentiate present competition categories.

  2. Identification and Antimicrobial Susceptibility Testing of Anaerobic Bacteria: Rubik's Cube of Clinical Microbiology?

    Science.gov (United States)

    Gajdács, Márió; Spengler, Gabriella; Urbán, Edit

    2017-11-07

    Anaerobic bacteria have pivotal roles in the microbiota of humans and they are significant infectious agents involved in many pathological processes, both in immunocompetent and immunocompromised individuals. Their isolation, cultivation and correct identification differs significantly from the workup of aerobic species, although the use of new technologies (e.g., matrix-assisted laser desorption/ionization time-of-flight mass spectrometry, whole genome sequencing) changed anaerobic diagnostics dramatically. In the past, antimicrobial susceptibility of these microorganisms showed predictable patterns and empirical therapy could be safely administered but recently a steady and clear increase in the resistance for several important drugs (β-lactams, clindamycin) has been observed worldwide. For this reason, antimicrobial susceptibility testing of anaerobic isolates for surveillance purposes or otherwise is of paramount importance but the availability of these testing methods is usually limited. In this present review, our aim was to give an overview of the methods currently available for the identification (using phenotypic characteristics, biochemical testing, gas-liquid chromatography, MALDI-TOF MS and WGS) and antimicrobial susceptibility testing (agar dilution, broth microdilution, disk diffusion, gradient tests, automated systems, phenotypic and molecular resistance detection techniques) of anaerobes, when should these methods be used and what are the recent developments in resistance patterns of anaerobic bacteria.

  3. Relationship between anaerobic parameters provided from MAOD and critical power model in specific table tennis test.

    Science.gov (United States)

    Zagatto, A M; Gobatto, C A

    2012-08-01

    The aim of this study was to verify the validity of the curvature constant parameter (W'), calculated from 2-parameter mathematical equations of critical power model, in estimating the anaerobic capacity and anaerobic work capacity from a table tennis-specific test. Specifically, we aimed to i) compare constants estimated from three critical intensity models in a table tennis-specific test (Cf); ii) correlate each estimated W' with the maximal accumulated oxygen deficit (MAOD); iii) correlate each W' with the total amount of anaerobic work (W ANAER) performed in each exercise bout performed during the Cf test. Nine national-standard male table tennis players participated in the study. MAOD was 63.0(10.8) mL · kg - 1 and W' values were 32.8(6.6) balls for the linear-frequency model, 38.3(6.9) balls for linear-total balls model, 48.7(8.9) balls for Nonlinear-2 parameter model. Estimated W' from the Nonlinear 2-parameter model was significantly different from W' from the other 2 models (P0.13). Thus, W' estimated from the 2-parameter mathematical equations did not correlate with MAOD or W ANAER in table tennis-specific tests, indicating that W' may not provide a strong and valid estimation of anaerobic capacity and anaerobic capacity work. © Georg Thieme Verlag KG Stuttgart · New York.

  4. Diminished anaerobic and aerobic exercise fitness in the hemoglobin E traits.

    Science.gov (United States)

    Chidnok, Weerapong; Jiraviriyakul, Arunya; Weerapun, Opor; Wasuntarawat, Chanchira

    2016-03-01

    There is no information about the exercise performances of the hemoglobin E trait (Hb EA), which is the second most prevalent hemoglobinopathy found in Southeast Asia and Mediterranean. The purpose of the present study was to compare both anaerobic and aerobic exercise performances between young male subjects with Hb EA and with normal hemoglobin (A2A). One hundred and twenty-two subjects underwent Hb EA Test screening, which revealed the presence of 17 subjects with Hb EA and 105 subjects with A2A. Thirteen subjects in each of the Hb EA and the normal hemoglobin groups were matched for race, age, height, weight, BMI, %body fat and physical activity profiles. All subjects performed the peak power output and anaerobic capacity tests using the Wingate protocol and the direct VO2max tests using a bicycle ergometer. The results were analyzed with the unpaired t-tests. The Hb EA subjects had lower (Panaerobic power (15.58±0.44 W.kg-1, mean±SEM), relative anaerobic capacity (6.50±0.16 W.kg-1) and maximal oxygen uptake (VO2max) (27.39±1.65 mL.kg-1.min-1) when compared to normal hemoglobin group (17.39±0.48 W.kg-1, 7.21±0.18 W.kg-1 and 33.05±1.59 mL.kg-1.min-1, respectively). The present study suggests that anaerobic exercise and aerobic exercise performances of the Hb EA subjects may be lower than matched normal hemoglobin subjects using the Wingate and the VO2max tests. However, the mechanisms of these results should be further investigated.

  5. Cardiovascular changes during the performance by nonathletes of Bosco repeated jumps anaerobic test

    Directory of Open Access Journals (Sweden)

    Jonas Poderys

    2015-01-01

    Conclusions: When performing Bosco 60-s repeated jumps in an anaerobic test, a maximal mobilization of the cardiovascular system occurs between 50 and 60 s. The 30-s all-out test duration in jumping is enough to outline at what extent cardiovascular function was mobilized as well as to assess other functional characteristics during high intensity intensive exercising.

  6. Effect of High Intensity Interval Training with Blood Restriction on Anaerobic Performance

    Directory of Open Access Journals (Sweden)

    Amir Behi

    2017-08-01

    Full Text Available Limiting venous blood flow restriction is a new approach of  training aims to improving high level of performance among athletes, which has shown prominent results at muscle hypotrophy and strength. KAATSU[1] is a training system including pressure belt imposed on the proximal part of the upper and lower bodies. The present study aims to investigate the effect of HIIT Kaatsu trainings on anaerobic performance among young athletes. The present quasi experimental research was conducted through a pre-test and post-test and three groups including KAATSU intensive interval exercises (n=11, intense interval exercise (n=9 and a control group (n=10. The exercises included running distances of 20 and 40 meters. In the beginning of the protocol most of the exercises was in short distances and as the sessions proceeded, the number of the sets and repetitions increased and it reached to its highest intensity in the last session. During the exercise protocol, intensity of training was considered to be the highest running speed and based on their abilities each individual tried to run as fast as possible. The exercise load was defined based on repetitions and the sets. In the 20 meters distances, the participants took a ten second rest after each repetition and a one minute rest after each set and in 40 meters distances; Subjects took a 20 second rest after each repetition and 2 minute rest between sets. The control group did not performed any of the mentioned exercises. Moreover, before and after four weeks of training the individuals were given RAST and Anaerobic Biking Wingate Test. Statistical result has been shown, there is a significant change between the maximum anaerobic power in Wingate biking test after four weeks within KAATSU intensive interval (P≥ 0.05 and intensive interval (P≥ 0.05 groups, but no significant change was detected in the control group (P> 0.05.  The statistical analysis of this research has been shown that there is

  7. Anaerobic-to-aerobic power ratio in children with juvenile idiopathic arthritis.

    Science.gov (United States)

    van Brussel, Marco; van Doren, Lieke; Timmons, Brian W; Obeid, Joyce; van der Net, Janjaap; Helders, Paul J M; Takken, Tim

    2009-06-15

    To examine the anaerobic-to-aerobic power ratio in children with juvenile idiopathic arthritis (JIA) compared with healthy peers. Sixty-two patients with JIA (mean +/- SD age 11.9 +/- 2.1 years, range 7.2-15.9 years) with varying severity of disease and 50 healthy children (mean +/- SD age 12.1 +/- 2.1, range 8.4-15.9 years) participated in this study. Anaerobic power was measured using the Wingate Anaerobic Exercise Test. Aerobic power was measured using a cardiopulmonary exercise test. The power ratio was calculated as the ratio between the anaerobic mechanical power and aerobic mechanical power in watts. Mean +/- SD anaerobic-to-aerobic power ratio and peak anaerobic-to-aerobic ratios in children with JIA were 1.98 +/- 0.51 and 3.28 +/- 1.15, respectively. Compared with healthy children these differences were not statistically significant (P = 0.52 and P = 0.99, respectively). The differences in these ratios were not statistically significant when corrected for age, height, and body mass. Statistical analyses showed no significant difference between disease-onset types of JIA for mean anaerobic-to-aerobic power ratio and peak anaerobic-to-aerobic ratio, respectively. Furthermore, there was no significant difference in the development of the power ratios between children with JIA and healthy controls, or between girls and boys. This cross-sectional study suggests that the development of the anaerobic-to-aerobic power ratio is not statistically different in children with JIA compared with healthy peers. Exercise training of the anaerobic capacity through interval training, along with aerobic exercise training, seems warranted in the exercise therapy programs of children with JIA.

  8. Aerobic and anaerobic exercise capacity in adolescents with juvenile idiopathic arthritis.

    Science.gov (United States)

    Lelieveld, Otto T H M; van Brussel, Marco; Takken, Tim; van Weert, Ellen; van Leeuwen, Miek A; Armbrust, Wineke

    2007-08-15

    To examine the aerobic and anaerobic exercise capacity in adolescents with juvenile idiopathic arthritis (JIA) compared with age- and sex-matched healthy individuals, and to assess associations between disease-related variables and aerobic and anaerobic exercise capacity. Of 25 patients enrolled in a JIA transition outpatient clinic, 22 patients with JIA were included in this study (mean +/- SD age 17.1 +/- 0.7 years, range 16-18 years). Aerobic capacity was examined using a Symptom Limited Bicycle Ergometry test. Anaerobic capacity was assessed with the Wingate Anaerobic Test. Functional ability was assessed with the Childhood Health Assessment Questionnaire. Pain and overall well-being were measured using a visual analog scale. Disease duration and disease activity were also assessed. Absolute and relative maximal oxygen consumption in the JIA group were significantly impaired (85% and 83% for boys, respectively; 81% and 78% for girls, respectively) compared with healthy controls. Mean power was also significantly impaired (88% for boys and 74% for girls), whereas peak power was significantly impaired for girls and just failed significance for boys (67% for girls and 92% for boys). A post hoc analysis correcting for underweight and overweight demonstrated that body composition did not influence the results substantially. This study demonstrated that adolescents with JIA have an impaired aerobic and anaerobic exercise capacity compared with healthy age- and sex-matched peers. The likely cause for this significant impairment is multifactorial and needs to be revealed to improve treatment strategies.

  9. Modified agar dilution method for rapid antibiotic susceptibility testing of anaerobic bacteria.

    Science.gov (United States)

    Hanson, C W; Martin, W J

    1978-01-01

    A simplified method has been developed for agar dilution antimicrobial susceptibility testing of anaerobic bacteria, designed to economize on time and money when only a few isolates need to be tested. The procedure is based on the principle of using filter paper disks as carriers of the antibiotic and 35- by 10-mm petri dishes which, when inoculated with the Steers replicator, can test up to four organisms per plate. The procedure was run in parallel with conventional agar dilution techniques and showed 95% agreement to within one dilution for all minimal inhibitory concentrations recorded on fresh anaerobic isolates from clinical specimens. The technique was further simplified by using commercially available antibiotic-containing disks, thereby alleviating the tedious and time-consuming procedure of preparing the disks. The data indicated that 48- to 72-h diffusion periods were sufficient to achieve a uniform concentration of the antibiotic in the petri plate and that the antibiotics were stable at room temperature for that period of time. In terms of applicability and relevance to the needs of the clinical microbiology laboratory, the modified agar dilution method for rapid antimicrobial susceptibility testing of individual anaerobic isolates was found to be superior to the broth dilution method since it was easier to read and required considerably less set up time. PMID:400819

  10. Parameters of anaerobic physiological profile of elite athletes

    Directory of Open Access Journals (Sweden)

    Karaba-Jakovljević Dea

    2015-01-01

    Full Text Available Introduction. Anaerobic capacity is much less evaluated in literature compared to aerobic component. Anaerobic performance of athletes can be measured using different motoric tests, lasting 20 to 30 seconds, one of them being the Wingate anaerobic test (WAnT. Objective. The aim of this study was to determine the work performed and power generated by athletes and non-athletes during a 30-second high intensity exercise, as well as to compare explosive characteristics of subjects using a new parameter of WAnT, named explosive power, or slope of power. Methods. All parameters of anaerobic power were investigated in 152 subjects classed into different groups depending on their physical fitness and sport specialties as follows: non-athletes (n=31, rowers (n=26, volleyball players (n=37, handball players (n=34 and judo players (n=24. The WAnT, as well as basic anthropometric measurements, was administrated to all participants. Results. Values of anaerobic parameters were higher in the group of athletes compared to physically inactive subjects. The highest values of the WAnT parameters were registered in the group of volleyball players (AP=1006 W; relative AP=11.4 W/ kg, AC=19.8 kJ, compared to athletes of other sport disciplines (volleyball, rowing and judo. The new parameter of the WAnT, explosive power, also showed highest values in volleyball players (EP=154 W/s; relative EP=1.74 W/s/kg. These differences were statistically significant (p<0.05. Conclusion. The results of laboratory tests can provide useful information on improvements in training processes. The new parameter of the WAnT could be implemented in further analyses of explosive characteristics of muscle contraction.

  11. Cardiovascular changes during the performance by nonathletes of Bosco repeated jumps anaerobic test

    OpenAIRE

    Poderys, Jonas; Grūnovas, Albinas; Poderienė, Kristina; Buliuolis, Alfonsas; Šilinskas, Viktoras; Trinkūnas, Eugenijus

    2015-01-01

    Objective: The aim of this study was to find out the characteristics of cardiovascular changes when performing Bosco repeated jumps anaerobic test depending on the duration of jumping in a nonathletes cohort. Materials and methods: Changes in arterial blood pressure indices and changes in 12-lead ECG indices were analyzed. The characteristics of recovery after workloads were assessed by evaluating the time of half period of recovery of registered indices and by the Lyapunov exponent. Re...

  12. Aerobic and Anaerobic Swimming Force Evaluation in One Single Test Session for Young Swimmers.

    Science.gov (United States)

    de Barros Sousa, Filipe Antônio; Rodrigues, Natalia Almeida; Messias, Leonardo Henrique Dalcheco; Queiroz, Jair Borges; Manchado-Gobatto, Fulvia Barros; Gobatto, Claudio Alexandre

    2017-05-01

    This study aims to propose and validate the tethered swimming lactate minimum test (TSLacmin) estimating aerobic and anaerobic capacity in one single test session, using force as measurement parameter. 6 male and 6 female young swimmers (age=15.7±1.1 years; height=173.3±9.5 cm; weight=66.1±9.5 kg) performed 4 sessions comprising i) an all-out 30 s test and incremental test (TSLacmin); ii) 30 min of tethered swimming at constant intensity (2 sessions); iii) free-swimming time trials used to calculate critical velocity. Tethered swimming sessions used an acquisition system enabling maximum (Fmax) and mean (Fmean) force measurement and intensity variation. The tethered all-out test lasting 30 s resulted in hyperlactatemia of 7.9±2.0 mmol·l(-1). TSLacmin presented a 100% success applicability rate, which is equivalent to aerobic capacity in 75% of cases. TSLacmin intensity was 37.7±7.3 N, while maximum force in the all-out test was 105±27 N. Aerobic and anaerobic TSLacmin parameters were significantly related to free-swimming performance (r=-0.67 for 100 m and r=-0.80 for 200 m) and critical velocity (r=0.80). TSLacmin estimates aerobic capacity in most cases, and both aerobic and anaerobic force parameters are well related to critical velocity and free swimming performance. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Comparison of the anaerobic power measured by the RAST test at different footwear and surfaces conditions

    OpenAIRE

    Kalva-Filho, Carlos Augusto; Loures, João Paulo; Franco, Vanessa Holtz; Kaminagakura, Edson Itaru; Zagatto, Alessandro Moura; Papoti, Marcelo

    2013-01-01

    INTRODUÇÃO: O Running Anaerobic Sprint Test (RAST) tem sido considerado um teste válido para avaliação anaeróbia. Entretanto, como a superfície e o calçado podem afetar alguns parâmetros mensurados durante o exercício, isso pode modificar os parâmetros do RAST. OBJETIVO: Comparar as variáveis do RAST mensuradas utilizando chuteiras na grama (RAST CG) e tênis na pista (RAST TP). MÉTODOS: Oito jogadores de futebol (da categoria sub-17) participaram do estudo. Os participantes realizaram dois RA...

  14. Effect of nutritionally enriched coffee consumption on aerobic and anaerobic exercise performance.

    Science.gov (United States)

    Hoffman, Jay R; Kang, Jie; Ratamess, Nicholas A; Jennings, Peter F; Mangine, Gerald T; Faigenbaum, Avery D

    2007-05-01

    The purpose of this study was to compare nutritionally enriched JavaFit coffee (JF) to commercially available decaffeinated coffee (P) with regard to impact on endurance and anaerobic power performance in a physically active, college-aged population. Ten subjects (8 men, 2 women) performed two 30-second Wingate anaerobic power tests and 2 cycle ergometer tests (75% VO2 max) to exhaustion. Mean VO2 was measured during each endurance exercise protocol. Excess postexercise oxygen consumption (EPOC) and respiratory exchange ratio (RER) were recorded for 30 minutes following all exercise sessions. Area under the curve analysis was used to compare EPOC between JF and P for all exercise sessions. No differences were seen between JF and P in any of the power performance measures. However, time to exhaustion was significantly (p = 0.05) higher in JF (35.3 +/- 15.2 minutes) compared with P (27.3 +/- 10.7 minutes). No difference between JF and P were seen in EPOC in either the aerobic or anaerobic exercise sessions. A significant (p coffee beverage appears to enhance time to exhaustion during aerobic exercise, but does not provide an ergogenic benefit during anaerobic exercise.

  15. Relationship between aerobic and anaerobic parameters and functional classification in wheelchair basketball players.

    Science.gov (United States)

    de Lira, C A B; Vancini, R L; Minozzo, F C; Sousa, B S; Dubas, J P; Andrade, M S; Steinberg, L L; da Silva, A C

    2010-08-01

    Participation in sports for individuals with disabilities continues to gain popularity. In order to provide fair and equitable competition among persons with different disabilities and functional capacity, a separate functional classification system has been devised for each sport. The aims of the present study were to evaluate aerobic and anaerobic performance of wheelchair basketball athletes and verify a correlation with the International Wheelchair Basketball Federation functional classification system. For this, 17 highly trained male Brazilian basketball wheelchair athletes (25.4+/-4.4 years) from the national team who had taken part in the Athens 2004 Paralympic Games were assessed. These athletes were submitted to cardiopulmonary exercise testing and Wingate-like 30-s sprint test using upper limbs. The present study demonstrated that the functional classification score correlated with relative (r=0.90; Pwheelchair basketball players.

  16. Compactional deformation bands in Wingate Sandstone; additional evidence of an impact origin for Upheaval Dome, Utah

    Science.gov (United States)

    Okubo, Chris H.; Schultz, Richard A.

    2007-04-01

    Field and microstructural observations from Upheaval Dome, in Canyonlands National Park, Utah, show that inelastic strain of the Wingate Sandstone is localized along compactional deformation bands. These bands are tabular discontinuities (Jurassic) age for this impact.

  17. Effects of psychological priming, video, and music on anaerobic exercise performance.

    Science.gov (United States)

    Loizou, G; Karageorghis, C I

    2015-12-01

    Peak performance videos accompanied by music can help athletes to optimize their pre-competition mindset and are often used. Priming techniques can be incorporated into such videos to influence athletes' motivational state. There has been limited empirical work investigating the combined effects of such stimuli on anaerobic performance. The present study examined the psychological and psychophysiological effects of video, music, and priming when used as a pre-performance intervention for an anaerobic endurance task. Psychological measures included the main axes of the circumplex model of affect and liking scores taken pre-task, and the Exercise-induced Feeling Inventory, which was administered post-task. Physiological measures comprised heart rate variability and heart rate recorded pre-task. Fifteen males (age = 26.3 ± 2.8 years) were exposed to four conditions prior to performing the Wingate Anaerobic Test: music-only, video and music, video with music and motivational primes, and a no-video/no-music control. Results indicate that the combined video, music, and primes condition was the most effective in terms of influencing participants' pre-task affect and subsequent anaerobic performance; this was followed by the music-only condition. The findings indicate the utility of such stimuli as a pre-performance technique to enhance athletes' or exercisers' psychological states. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Plasma protein carbonyl responses to anaerobic exercise in female cyclists

    Directory of Open Access Journals (Sweden)

    M.E Afzalpour

    2016-03-01

    Full Text Available Single bouts of aerobic exercise may leads to oxidative stress due to the use of oxygen for metabolism and the generation of reactive oxygen. In athletes, oxidative stress can lead to several deleterious performance effects, such as muscular oxidative damage, muscle soreness, loss of skeletal muscle force production and/or inflammation. However, little is known regarding the severity and duration of oxidative stress arising from intensive anaerobic modes of exercise in aerobically-trained athletes. The purpose of this study was to investigate the effect of a single bout of intensive anaerobic exercise on plasma protein carbonyl (PC in aerobically-trained women. Aerobically-trained, provincial female cyclists [n = 18, age: 24.2±2.7 years; stature: 163.6±4.6 cm; body mass: 53.4±4.2 kg] were randomly assigned into either a non-exercising control (CON; n = 9 or experimental (EXP; n = 9 group that underwent a 30-second anaerobic (Wingate cycle ergometer exercise session. Blood sampling took place before exercise, immediately after the exercise (IE, and 24 hours following the exercise (24HR bout. In the EXP, results indicated significant (P ≤ 0.05 differences in PC levels between the pre-test and IE (0.010±0.0124 to 0.0149±0.0420 mmol/milt; P = 0.010, and IE and 24HR (0.0149±0.0420 to 0.0111±0.0183 mmol/milt; P = 0.013. No significant differences were observed between pre-test and 24HR (0.010±0.0124 to 0.0111±0.0183 mmol/milt; P = 0.371. These results indicate that oxidative protein damage, as indicated by PC levels, rises immediately with the onset of anaerobic exercise, but returns to resting levels within 24 hours following exercise in aerobically-trained women.

  19. Effects of a competitive wrestling season on body composition, endocrine markers, and anaerobic exercise performance in NCAA collegiate wrestlers.

    Science.gov (United States)

    Ratamess, Nicholas A; Hoffman, Jay R; Kraemer, William J; Ross, Ryan E; Tranchina, Christopher P; Rashti, Stefanie L; Kelly, Neil A; Vingren, Jakob L; Kang, Jie; Faigenbaum, Avery D

    2013-05-01

    Few data exist examining the body composition, endocrine, and anaerobic exercise performance changes over a competitive wrestling season. Eighteen NCAA wrestlers were tested for endocrine markers, body composition, hydration, grip strength, and power on four occasions: prior to pre-season training (T1); after pre-season training 3 days prior to the first seasonal meet (T2); mid-season one day prior to a meet (T3); and at the end of the season 2-3 days following the last meet (T4). Body mass, percent body fat (BF %), and fat mass were significantly lower (P ≤ 0.05) at T2 and T3 compared to T1 but were not different between T1 and T4. Lean body mass was significantly reduced at T2 only. Urine specific gravity was significantly elevated at T3 compared to T1, T2, and T4. Resting cortisol concentrations did not change but resting testosterone concentrations were significantly reduced at T2, T3, and T4. Maximal grip strength was significantly reduced at T2. Vertical jump peak power was significantly reduced at T2, T3, and T4. Wingate peak power was significantly reduced at T2 and T3. However, Wingate average power and total work did not significantly change. Fatigue rate during the Wingate test was significantly improved at T2, T3, and T4 compared to T1. In conclusion, body mass, BF %, and measures of peak force and power were reduced for most of the competitive wrestling season. Competitive wrestling reduces resting total testosterone concentrations throughout the entire season.

  20. Aerobic and anaerobic exercise capacity in children with juvenile idiopathic arthritis.

    Science.gov (United States)

    van Brussel, M; Lelieveld, O T H M; van der Net, J; Engelbert, R H H; Helders, P J M; Takken, T

    2007-08-15

    To compare the aerobic and anaerobic exercise capacity of children with juvenile idiopathic arthritis (JIA) with healthy controls, to determine if there were differences based on disease onset type, and to examine the relationship between aerobic and anaerobic exercise capacity in children with JIA. Sixty-two patients with JIA (mean +/- SD age 11.9 +/- 2.2 years, range 6.7-15.9) participated in this study. Aerobic exercise capacity was measured using a cardiopulmonary exercise test. Anaerobic exercise capacity was measured using the Wingate Anaerobic Exercise Test (WAnT). All patients were able to perform the cardiopulmonary exercise test and WAnT without adverse events. On average, the maximal oxygen uptake (VO(2peak)) and VO(2peak/kg) were 69.8% and 74.8%, respectively, of that predicted compared with healthy controls. Mean +/- SD power was 66.7% +/- 37.2% of that predicted compared with healthy children. Mean +/- SD peak power was 65.5% +/- 43.1% of that predicted compared with healthy children. There were significant differences between subgroups of JIA; the oligoarticular-onset group values did not significantly differ from healthy control values; the polyarticular rheumatoid factor positive-onset subgroup had the greatest impairment in both aerobic and anaerobic exercise capacity. The correlations of mean power and peak power with VO(2peak) were r = 0.884 and r = 0.697, respectively (P anaerobic exercise capacity in children with JIA are significantly decreased. The WAnT might be a valuable adjunct to other assessment tools in the followup of patients with JIA.

  1. Near-infrared spectroscopic monitoring during cardiopulmonary exercise testing detects anaerobic threshold.

    Science.gov (United States)

    Rao, Rohit P; Danduran, Michael J; Loomba, Rohit S; Dixon, Jennifer E; Hoffman, George M

    2012-06-01

    Cardiopulmonary exercise testing (CPET) provides assessment of the integrative responses involving the pulmonary, cardiovascular, and skeletal muscle systems. Application of exercise testing remains limited to children who are able to understand and cooperate with the exercise protocol. Near-infrared spectroscopy (NIRS) provides a noninvasive, continuous method to monitor regional tissue oxygenation (rSO2). Our specific aim was to predict anaerobic threshold (AT) during CPET noninvasively using two-site NIRS monitoring. Achievement of a practical noninvasive technology for estimating AT will increase the compatibility of CPET. Patients without structural or acquired heart disease were eligible for inclusion if they were ordered to undergo CPET by a cardiologist. Data from 51 subjects was analyzed. The ventilatory anaerobic threshold (VAT) was computed on [Formula: see text] and respiratory quotient post hoc using the standard V-slope method. The inflection points of the regional rSO2 time-series were identified as the noninvasive regional NIRS AT for each of the two monitored regions (cerebral and kidney). AT calculation made using an average of kidney and brain NIRS matched the calculation made by VAT for the same patient. Two-site NIRS monitoring of visceral organs is a predictor of AT.

  2. Cardiovascular changes during the performance by nonathletes of Bosco repeated jumps anaerobic test.

    Science.gov (United States)

    Poderys, Jonas; Grūnovas, Albinas; Poderienė, Kristina; Buliuolis, Alfonsas; Šilinskas, Viktoras; Trinkūnas, Eugenijus

    2015-01-01

    The aim of this study was to find out the characteristics of cardiovascular changes when performing Bosco repeated jumps anaerobic test depending on the duration of jumping in a nonathletes cohort. Changes in arterial blood pressure indices and changes in 12-lead ECG indices were analyzed. The characteristics of recovery after workloads were assessed by evaluating the time of half period of recovery of registered indices and by the Lyapunov exponent. The results have shown that the ratio of JT and RR intervals of ECG (JT/RR) can be useful for outlining to what extent a cardiovascular function was mobilized. The mobilization of cardiovascular function when performing a 30-s jump test changed up to 0.454±0.012 and when performing a Bosco test, up to the maximal values, i.e. 0.634±0.004. When performing jumps of maximal intensity, a maximal change of JT/RR occurrence was between 50 and 60s. The increasingly serious myocardial ischemic episodes were observed at the onset of the jumping task. The duration of 60-s of all-out jump test has made an influence on the stability of the recovery processes of cardiovascular indices, i.e. the nonexponential type of recovery was observed. When performing Bosco 60-s repeated jumps in an anaerobic test, a maximal mobilization of the cardiovascular system occurs between 50 and 60s. The 30-s all-out test duration in jumping is enough to outline at what extent cardiovascular function was mobilized as well as to assess other functional characteristics during high intensity intensive exercising. Copyright © 2015 Lithuanian University of Health Sciences. Production and hosting by Elsevier Urban & Partner Sp. z o.o. All rights reserved.

  3. [First Argentine consensus guidelines for in vitro antimicrobial susceptibility testing of clinically relevant anaerobic bacteria in humans/ Anaerobic Subcommittee of the Asociación Argentina de Microbiología].

    Science.gov (United States)

    Legaria, María C; Bianchini, Hebe M; Castello, Liliana; Carloni, Graciela; Di Martino, Ana; Fernández Canigia, Liliana; Litterio, Mirta; Rollet, Raquel; Rossetti, Adelaida; Predari, Silvia C

    2011-01-01

    Through time, anaerobic bacteria have shown good susceptibility to clinically useful antianaerobic agents. Nevertheless, the antimicrobial resistance profile of most of the anaerobic species related to severe infections in humans has been modified in the last years and different kinds of resistance to the most active agents have emerged, making their effectiveness less predictable. With the aim of finding an answer and for the purpose of facilitating the detection of anaerobic antimicrobial resistance, the Anaerobic Subcommittee of the Asociación Argentina de Microbiología developed the First Argentine consensus guidelines for in vitro antimicrobial susceptibility testing of clinically relevant anaerobic bacteria in humans. This document resulted from the compatibilization of the Clinical and Laboratory Standards Institute recommendations, the international literature and the work and experience of the Subcommittee. The Consensus document provides a brief taxonomy review, and exposes why and when anaerobic antimicrobial susceptibility tests should be conducted, and which antimicrobial agents can be used according to the species involved. The recommendations on how to perform, read and interpret in vitro anaerobic antimicrobial susceptibility tests with each method are exposed. Finally, the antibiotic susceptibility profile, the classification of antibiotics according to their in vitro activities, the natural and acquired mechanisms of resistance, the emerging resistance and the regional antibiotic resistance profile of clinically relevant anaerobic species are shown.

  4. Validity and reliability of incremental test to determine the anaerobic threshold in swimming rats

    Directory of Open Access Journals (Sweden)

    Wladimir Rafael Beck

    2015-04-01

    Full Text Available The organic and metabolic consequences of physical exercise are critically modulated depending of the effort intensity and volume. Nevertheless, most of the protocols employed for objectively determine the individual exercise intensities for rats are impractical or unadvisable for various experimental designs. The aim of this study was to individually determine the anaerobic threshold intensity (iAnT and the maximal lactate steady state (MLSS, gold standard procedure intensities using a single incremental swimming test for rats, verifying it validity and reliability. Eleven male Wistar rats were submitted twice (48 hours of interval to an incremental test with overloads from 3% of body mass (%bm, increments of 0.5%bm and stages of 5 min. From blood lactate concentration and %bm data were constructed two linear regressions to determine iAnT. Then, all of the animals performed the MLSS procedure based on iAnT. Comparing iAnT test and re-test were found significant intraclass correlation (r = 0.67; p = 0.01, no significant difference (p = 0.91, coefficient of variation of 4.04% and effect size of 0.02, beyond good agreement, precision and accuracy attested by Bland-Altman plots (bias of 0.010. Furthermore, iAnT was not different from MLSS intensity. A single incremental swimming test comprises a high applicable, valid and reliable tool for objectively and individually determines exercise intensity of swimming rats. Keywords: Anaerobic threshold; exercise intensity; lactataemia; maximal lactate steady state; swimming rats

  5. Operating tests analysis of liquid biologically degradable waste processing by anaerobic fermentation

    Directory of Open Access Journals (Sweden)

    Jiří Fryč

    2012-01-01

    Full Text Available This study concerns the analysis of operating anaerobic fermentation systems of agricultural biogas station and implementing a suitable system enabling the use of liquid biowaste. Based on the comparison of the technological solutions and operating parameters of specific equipment a system enabling the utilisation of biowaste has been designed. The tests made use of liquid substrates commercially offered to biogas station operators. The study evaluates practical measurements at an agricultural biogas station in order to evaluate the biogas production from these substrates and the efficiency of transforming input material to usable energy. The use of such treated substrates for the anaerobic fermentation technology may have a substantial influence on the volume of dosed energy crops. The mixture of input substrates consisting of liquid cattle excrements, silage corn, liquid food-processing waste, animal waste and glycerine water was experimentally validated. This mixture was compared with the operation using liquid cattle excrements and silage corn. It was concluded that the proposed composition of input raw materials makes it possible to increase the production of biogas and el. power. On the other hand, it was identified that the energy content of the input raw materials is not optimally transformed into usable energy. Therefore, the proposed mixture of input materials with biowaste is not recommended for use.

  6. Energy Systems Contribution in the Running-based Anaerobic Sprint Test.

    Science.gov (United States)

    Milioni, F; Zagatto, A M; Barbieri, R A; Andrade, V L; Dos Santos, J W; Gobatto, C A; da Silva, A S R; Santiago, P R P; Papoti, M

    2017-03-01

    The aims of the present study were to verify the contributions of the energy systems during repeated sprints with a short recovery time and the associations of the time- and power-performance of repeated sprints with energetic contributions and aerobic and anaerobic variables. 13 healthy men performed the running-based anaerobic sprint test (RAST) followed by an incremental protocol for lactate minimum intensity determination. During the RAST, the net energy system was estimated using the oxygen consumption and the blood lactate responses. The relative contributions of oxidative phosphorylation, glycolytic, and phosphagen pathways were 38, 34, and 28%, respectively. The contribution of the oxidative pathway increased significantly during RAST especially from the third sprint, at the same time that power- and time-performances decreases significantly. The phosphagen pathway was associated with power-performance (peak power=432±107 W, r=0.65; mean power=325±80 W, r=0.65; minimum power=241±77 W, r=0.57; force impulse=1 846±478 N·s, r=0.74; p+0.65; p0.58; p<0.05). The oxidative pathway appears to play an important role in better recovery between sprints, and the continued use of the glycolytic metabolic pathway seems to decrease sprint performances. Finally, the phosphagen pathway was linked to power production/maintenance. © Georg Thieme Verlag KG Stuttgart · New York.

  7. Assessment and Differences in Anaerobic Capacity of Football Players Playing on Different Positions in the Team, Using Rast Test

    Directory of Open Access Journals (Sweden)

    Slobodan Andrašić

    2016-10-01

    Full Text Available Today's rapid development of football in all stages allocates a dominant role to conditional training. Players who participated in the study played in the 4:4:2 formation, therefore the classification has been made according to the playing position in the aforementioned system. The total sample of respondents consisted of 60 players at the cadet level (14 to 16 years medically fit for playing football and without any morphological and motor aberrations. The study applied pitch RAST test, which is very convenient for conducting and obtaining fast results on the anaerobic capacity of football players. In addition to this test, the assessment of anaerobic capacity uses the modified Bangsbo test. This research has demonstrated the importance of anaerobic capacity of certain players playing in different positions

  8. ASSESSMENT OF ANAEROBIC THRESHOLD IN FOOTBALL PLAYERS ON DIFFERENT POSITIONS, USING THE CONCONI TEST

    Directory of Open Access Journals (Sweden)

    Milan Cvetković

    2014-06-01

    Full Text Available Introduction: Requirements and needs of properly programmed training process, especially in the pre-season, look for a precise definition of the functional parameters of all the players. The level of anaerobic threshold, as well as research on the same, may be a good indicator of proper dosage of loading. The aim of the research is to determine the differences in running speed and heart rate at the level of anaerobic threshold in relation to the position of the player. Methods: Age of the respondents in this study included boys from 14 to 16 years of age (60 football players. The sample of respondents was divided according to playing position, as follows: center-backs (12 players, wing-backs (15 players, midfielders (14 players, forwarders (13 players and goalkeepers (6 goalkeepers. An estimation of maximum heart rate and anaerobic threshold was performed using the Conconi test – (Conconi et al. 1996. Prior to testing players had ten minutes to warm up and after a few minutes of rest the testing began. Players started with jogging test (10 km/h and after every 200 m running speed was increased by 0.5 km/h. Within certain sections the load is constant which is achieved by increasing speed after each 200 m, and then maintaining that speed until the end of the section. After processing the results within the particular software (“Polar Precision Performance SW” the values needed for this research were collected. Multivariate methods MANOVA and discriminant analysis will be applied in the paper. Regarding the univariate procedures, ANOVA t-test and Roy’s test shall be applied. The descriptive parameters, mean value, standard deviation (SD, minimum and maximum of all values, the coefficient of variation (CV of confidence intervals, skewness as the measures of asymmetry, kurtosis as the measure of flatness and the value of the Kolmogorov-Smirnov test, shall be presented. Results: By using the multivariate analysis of variance and based on the

  9. IMPACT OF 10 SESSIONS OF WHOLE BODY CRYOSTIMULATION ON AEROBIC AND ANAEROBIC CAPACITY AND ON SELECTED BLOOD COUNT PARAMETERS

    Directory of Open Access Journals (Sweden)

    Tomasz Dybek

    2012-01-01

    Full Text Available The systemic effect of low temperature suggests that sessions in a cryogenic chamber might improve athletes’ capacity as a standard element of training. Therefore the authors decided to evaluate the impact of 10 sessions of whole body cryostimulation (WBCT on aerobic and anaerobic efficiency as well as on selected blood count parameters. The study group included 32 volunteers – 16 women and 16 men. The volunteers underwent 10 sessions of WBCT in a cryogenic chamber. Blood samples (RBC, WBC, PLT, HGB, HCT were taken, and aerobic and anaerobic efficiency and lactate concentration in capillary blood were measured before the first session and one day after the last one. No significant differences were observed in values of aerobic capacity after 10 sessions of WBCT. There was a rising trend in men and a declining trend in women. The lactate concentration did not differ significantly before and after WBCT. A slight rise in aerobic and anaerobic threshold was observed in men, while in women the values slightly fell. The Wingate test showed no significant differences in results before and after cryostimulation. Only the TOBT was significantly shorter in men (6.12±1.49 vs 3.79±1.14 s. The WBCT sessions resulted in a significant rise of the haematological parameters both in women and men, excluding HCT, which showed a statistically insignificant rise. Ten sessions of whole body cryostimulation did not affect aerobic or anaerobic capacity in the tested group, although it improved the blood count parameters.

  10. Intermittent hypoxic training improves anaerobic performance in competitive swimmers when implemented into a direct competition mesocycle.

    Science.gov (United States)

    Czuba, Miłosz; Wilk, Robert; Karpiński, Jakub; Chalimoniuk, Małgorzata; Zajac, Adam; Langfort, Józef

    2017-01-01

    The main objective of this research was to evaluate the efficacy of intermittent hypoxic training (IHT) on anaerobic and aerobic capacity and swimming performance in well-trained swimmers. Sixteen male swimmers were randomly divided into a hypoxia (H) group (n = 8), which trained in a normobaric hypoxia environment, and a control (C) group (n = 8), which exercised under normoxic conditions. However, one participant left the study without explanation. During the experiment group H trained on land twice per week in simulated hypoxia (FiO2 = 15.5%, corresponding to 2,500 m a.s.l); however, they conducted swim training in normoxic conditions. Group C performed the same training program under normoxic conditions. The training program included four weekly microcyles, followed by three days of recovery. During practice sessions on land, the swimmers performed 30 second sprints on an arm-ergometer, alternating with two minute high intensity intervals on a lower limb cycle ergometer. The results showed that the training on land caused a significant (p<0.05) increase in absolute maximal workload (WRmax) by 7.4% in group H and by 3.2% in group C and relative values of VO2max by 6.9% in group H and 3.7% in group C. However, absolute values of VO2max were not significantly changed. Additionally, a significant (p<0.05) increase in mean power (Pmean) during the first (11.7%) and second (11.9%) Wingate tests was only observed in group H. The delta values of lactate concentration (ΔLA) after both Wingate tests were significantly (p<0.05) higher in comparison to baseline levels by 28.8% in group H. Opposite changes were observed in delta values of blood pH (ΔpH) after both Wingate tests in group H, with a significant decrease in values of ΔpH by 33.3%. The IHT caused a significant (p<0.05) improvement in 100m and 200m swimming performance, by 2.1% and 1.8%, respectively in group H. Training in normoxia (group C), resulted in a significant (p<0.05) improvement of swimming

  11. Intermittent hypoxic training improves anaerobic performance in competitive swimmers when implemented into a direct competition mesocycle.

    Directory of Open Access Journals (Sweden)

    Miłosz Czuba

    Full Text Available The main objective of this research was to evaluate the efficacy of intermittent hypoxic training (IHT on anaerobic and aerobic capacity and swimming performance in well-trained swimmers. Sixteen male swimmers were randomly divided into a hypoxia (H group (n = 8, which trained in a normobaric hypoxia environment, and a control (C group (n = 8, which exercised under normoxic conditions. However, one participant left the study without explanation. During the experiment group H trained on land twice per week in simulated hypoxia (FiO2 = 15.5%, corresponding to 2,500 m a.s.l; however, they conducted swim training in normoxic conditions. Group C performed the same training program under normoxic conditions. The training program included four weekly microcyles, followed by three days of recovery. During practice sessions on land, the swimmers performed 30 second sprints on an arm-ergometer, alternating with two minute high intensity intervals on a lower limb cycle ergometer. The results showed that the training on land caused a significant (p<0.05 increase in absolute maximal workload (WRmax by 7.4% in group H and by 3.2% in group C and relative values of VO2max by 6.9% in group H and 3.7% in group C. However, absolute values of VO2max were not significantly changed. Additionally, a significant (p<0.05 increase in mean power (Pmean during the first (11.7% and second (11.9% Wingate tests was only observed in group H. The delta values of lactate concentration (ΔLA after both Wingate tests were significantly (p<0.05 higher in comparison to baseline levels by 28.8% in group H. Opposite changes were observed in delta values of blood pH (ΔpH after both Wingate tests in group H, with a significant decrease in values of ΔpH by 33.3%. The IHT caused a significant (p<0.05 improvement in 100m and 200m swimming performance, by 2.1% and 1.8%, respectively in group H. Training in normoxia (group C, resulted in a significant (p<0.05 improvement of swimming

  12. A Randomised, Placebo-Controlled, Crossover Study Investigating the Effects of Nicotine Gum on Strength, Power and Anaerobic Performance in Nicotine-Naïve, Active Males.

    Science.gov (United States)

    Mündel, Toby; Machal, Marine; Cochrane, Darryl J; Barnes, Matthew J

    2017-12-01

    Nicotine use amongst athletes is high and increasing, especially team sports, yet the limited previous studies investigating the performance consequences of this behaviour have not examined the effects of the principal active ingredient, nicotine, per se. Therefore, we determined whether nicotine gum affected muscular and anaerobic performance. Nine active males (24 ± 3 years) completed three trials in a random order in which 20 min prior to testing they chewed 2 mg (NIC-2), 4 mg (NIC-4) nicotine or flavour-matched placebo (PLA) gum. Peak and average peak isometric, concentric and eccentric leg extensor torque was measured followed by vertical counter-movement jump height and a 30-s Wingate test. Heart rate was measured whilst capillary blood samples determined pH, HCO3(-) and venous blood confirmed the presence of nicotine. Nicotine was confirmed by the presence of its major metabolite, cotinine and participants reported no side effects with nicotine. Peak and average peak isometric and eccentric torque was significantly affected (NIC-2 > PLA; p NIC-2 > PLA; p  0.05) concentric torque was different between trials. Counter-movement jump height was similar across trials (p > 0.05). Anaerobic capacity during the Wingate remained similar across trials (p > 0.05); however, pacing strategy (peak power and rate of fatigue) was different during NIC-2 than PLA. pH was affected by nicotine (NIC-2 > PLA; p  0.05) although it was also reduced following the Wingate (p NIC-2/NIC-4 > PLA; p < 0.05). Chewing low-dose (2 mg) nicotine gum 20 min prior to exercise significantly improved leg extensor torque but did not affect counter-movement jump height or Wingate performance compared to a placebo, whilst there were minimal effects of the 4 mg nicotine gum on the performance parameters measured.

  13. Effects of ingesting JavaFit Energy Extreme functional coffee on aerobic and anaerobic fitness markers in recreationally-active coffee consumers.

    Science.gov (United States)

    Roberts, Michael D; Taylor, Lemuel W; Wismann, Jennifer A; Wilborn, Colin D; Kreider, Richard B; Willoughby, Darryn S

    2007-12-08

    The purpose of this study was to examine the effects of ingesting JavaFittrade mark Energy Extreme (JEE) on aerobic and anaerobic performance measures in recreationally-active male and female coffee drinkers. Five male (27.6 +/- 4.2 yrs, 93.2 +/- 11.7 kg, 181.6 +/- 6.9 cm) and five female (29 +/- 4.6 yrs, 61.5 +/- 9.2 kg, 167.6 +/- 6.9 cm) regular coffee drinkers (i.e., 223.9 +/- 62.7 mg.d-1 of caffeine) participated in this study. In a cross-over, randomized design, participants performed a baseline (BASELINE) graded treadmill test (GXT) for peak VO2 assessment and a Wingate test for peak power. Approximately 3-4 d following BASELINE testing, participants returned to the lab for the first trial and ingested 354 ml of either JEE or decaffeinated coffee (DECAF), after which they performed a GXT and Wingate test. Criterion measures during the GXT included an assessment of peakVO2 at maximal exercise, as well as VO2 at 3 minutes and 10 minutes post-exercise. Additionally, time-to-exhaustion (TTE), maximal RPE, mean heart rate (HR), mean systolic pressure (SBP), and mean diastolic blood pressure (DBP) were measured during each condition. Criterion measures for the Wingate included mean HR, SBP, DBP, peak power, and time to peak power (TTP). Participants then returned to the lab approximately one week later to perform the second trial under the same conditions as the first, except consuming the remaining coffee. Data were analyzed using a one way ANOVA (p < 0.05). Our results indicate that JEE significantly increased VO2 at 3 minutes post-exercise when compared to BASELINE (p = 0.04) and DECAF (p = 0.02) values, which may be beneficial in enhancing post-exercise fat metabolism.

  14. Effects of ingesting JavaFit Energy Extreme functional coffee on aerobic and anaerobic fitness markers in recreationally-active coffee consumers

    Directory of Open Access Journals (Sweden)

    Kreider Richard B

    2007-12-01

    Full Text Available Abstract The purpose of this study was to examine the effects of ingesting JavaFit™ Energy Extreme (JEE on aerobic and anaerobic performance measures in recreationally-active male and female coffee drinkers. Five male (27.6 ± 4.2 yrs, 93.2 ± 11.7 kg, 181.6 ± 6.9 cm and five female (29 ± 4.6 yrs, 61.5 ± 9.2 kg, 167.6 ± 6.9 cm regular coffee drinkers (i.e., 223.9 ± 62.7 mg·d-1 of caffeine participated in this study. In a cross-over, randomized design, participants performed a baseline (BASELINE graded treadmill test (GXT for peak VO2 assessment and a Wingate test for peak power. Approximately 3–4 d following BASELINE testing, participants returned to the lab for the first trial and ingested 354 ml of either JEE or decaffeinated coffee (DECAF, after which they performed a GXT and Wingate test. Criterion measures during the GXT included an assessment of peakVO2 at maximal exercise, as well as VO2 at 3 minutes and 10 minutes post-exercise. Additionally, time-to-exhaustion (TTE, maximal RPE, mean heart rate (HR, mean systolic pressure (SBP, and mean diastolic blood pressure (DBP were measured during each condition. Criterion measures for the Wingate included mean HR, SBP, DBP, peak power, and time to peak power (TTP. Participants then returned to the lab approximately one week later to perform the second trial under the same conditions as the first, except consuming the remaining coffee. Data were analyzed using a one way ANOVA (p 2 at 3 minutes post-exercise when compared to BASELINE (p = 0.04 and DECAF (p = 0.02 values, which may be beneficial in enhancing post-exercise fat metabolism.

  15. Anaerobic Capacityestimated in A Single Supramaximal Test in Cycling: Validity and Reliability Analysis.

    Science.gov (United States)

    Miyagi, Willian Eiji; de Poli, Rodrigo de Araujo Bonetti; Papoti, Marcelo; Bertuzzi, Romulo; Zagatto, Alessandro Moura

    2017-02-13

    The aim was to verify the validity (i.e., study A) and reliability (i.e., study B) of the alternative maximal accumulated oxygen deficit determined using onlya supramaximal effort (MAODALT)to estimate anaerobic capacity [i.e., estimated by the gold standard maximal accumulated oxygen deficit method (MAOD)] during cycling. In study A, the effects of supramaximal intensities on MAODALT and the comparison with the MAOD were investigated in fourteen active subjects (26 ± 6 years). In study B, the test-retest reliability was investigated, where fourteen male amateur cyclists (29 ± 5 years) performed the MAODALT twice at 115% of the intensity associated to maximal oxygen uptake (). MAODALT determined at 130 and 150% of was lower than MAOD (p ≤ 0.048), but no differences between MAODALT determined at 100, 105, 110, 115, 120 and 140% of (3.58 ± 0.53L; 3.58 ± 0.59L; 3.53 ± 0.52L; 3.48 ± 0.72L; 3.52 ± 0.61L and 3.46 ± 0.69L, respectively) with MAOD (3.99 ± 0.64L). The MAODALT determined from the intensities between 110 and 120% of presented the better agreement and concordance with MAOD. In the test-retest, the MAODALT was not different (p > 0.05), showed high reproducibility when expressed in absolute values (ICC = 0.96, p < 0.01), and a good level of agreement in the Bland-Altman plot analysis (mean differences ± CI95%:-0.16 ± 0.53L). Thus, the MAODALT seems to be valid and reliable to assess anaerobic capacity in cycling.

  16. Aerobic and anaerobic determinants of repeated sprint ability in team sports athletes

    Science.gov (United States)

    Dardouri, W; Haj-Sassi, R; Chamari, K; Souissi, N

    2015-01-01

    The aim of this study was to examine in team sports athletes the relationship between repeated sprint ability (RSA) indices and both aerobic and anaerobic fitness components. Sixteen team-sport players were included (age, 23.4 ± 2.3 years; weight, 71.2 ± 8.3 kg; height, 178 ± 7 cm; body mass index, 22.4 ± 2 kg · m−2; estimated VO2max, 54.16 ± 3.5 mL · kg−1 · min−1). Subjects were licensed in various team sports: soccer (n = 8), basketball (n = 5), and handball (n = 3). They performed 4 tests: the 20 m multi-stage shuttle run test (MSRT), the 30-s Wingate test (WingT), the Maximal Anaerobic Shuttle Running Test (MASRT), and the RSA test (10 repetitions of 30 m shuttle sprints (15 + 15 m with 180° change of direction) with 30 s passive recovery in between). Pearson's product moment of correlation among the different physical tests was performed. No significant correlations were found between any RSA test indices and WingT. However, negative correlations were found between MASRT and RSA total sprint time (TT) and fatigue index (FI) (r = -0.53, p < 0.05 and r = -0.65, p < 0.01, respectively). No significant relationship between VO2max and RSA peak sprint time (PT) and total sprint time (TT) was found. Nevertheless, VO2max was significantly correlated with the RSA FI (r = -0.57, p < 0.05). In conclusion, aerobic fitness is an important factor influencing the ability to resist fatigue during RSA exercise. Our results highlighted the usefulness of MASRT, in contrast to WingT, as a specific anaerobic testing procedure to identify the anaerobic energy system contribution during RSA. PMID:26424923

  17. Aerobic and anaerobic determinants of repeated sprint ability in team sports athletes

    Directory of Open Access Journals (Sweden)

    Z Gharbi

    2015-09-01

    Full Text Available The aim of this study was to examine in team sports athletes the relationship between repeated sprint ability (RSA indices and both aerobic and anaerobic fitness components. Sixteen team-sport players were included (age, 23.4 ± 2.3 years; weight, 71.2 ± 8.3 kg; height, 178 ± 7 cm; body mass index, 22.4 ± 2 kg · m -2 ; estimated VO 2 max, 54.16 ± 3.5 mL · kg-1 · min-1. Subjects were licensed in various team sports: soccer (n = 8, basketball (n = 5, and handball (n = 3. They performed 4 tests: the 20 m multi-stage shuttle run test (MSRT, the 30-s Wingate test (WingT, the Maximal Anaerobic Shuttle Running Test (MASRT, and the RSA test (10 repetitions of 30 m shuttle sprints (15 + 15 m with 180° change of direction with 30 s passive recovery in between. Pearson’s product moment of correlation among the different physical tests was performed. No significant correlations were found between any RSA test indices and WingT. However, negative correlations were found between MASRT and RSA total sprint time (TT and fatigue index (FI (r = -0.53, p < 0.05 and r = -0.65, p < 0.01, respectively. No significant relationship between VO 2 max and RSA peak sprint time (PT and total sprint time (TT was found. Nevertheless, VO 2 max was significantly correlated with the RSA FI (r = -0.57, p < 0.05. In conclusion, aerobic fitness is an important factor influencing the ability to resist fatigue during RSA exercise. Our results highlighted the usefulness of MASRT, in contrast to WingT, as a specific anaerobic testing procedure to identify the anaerobic energy system contribution during RSA.

  18. Aerobic and anaerobic determinants of repeated sprint ability in team sports athletes.

    Science.gov (United States)

    Gharbi, Z; Dardouri, W; Haj-Sassi, R; Chamari, K; Souissi, N

    2015-09-01

    The aim of this study was to examine in team sports athletes the relationship between repeated sprint ability (RSA) indices and both aerobic and anaerobic fitness components. Sixteen team-sport players were included (age, 23.4 ± 2.3 years; weight, 71.2 ± 8.3 kg; height, 178 ± 7 cm; body mass index, 22.4 ± 2 kg · m(-2); estimated VO2max, 54.16 ± 3.5 mL · kg(-1) · min(-1)). Subjects were licensed in various team sports: soccer (n = 8), basketball (n = 5), and handball (n = 3). They performed 4 tests: the 20 m multi-stage shuttle run test (MSRT), the 30-s Wingate test (WingT), the Maximal Anaerobic Shuttle Running Test (MASRT), and the RSA test (10 repetitions of 30 m shuttle sprints (15 + 15 m with 180° change of direction) with 30 s passive recovery in between). Pearson's product moment of correlation among the different physical tests was performed. No significant correlations were found between any RSA test indices and WingT. However, negative correlations were found between MASRT and RSA total sprint time (TT) and fatigue index (FI) (r = -0.53, p < 0.05 and r = -0.65, p < 0.01, respectively). No significant relationship between VO2max and RSA peak sprint time (PT) and total sprint time (TT) was found. Nevertheless, VO2max was significantly correlated with the RSA FI (r = -0.57, p < 0.05). In conclusion, aerobic fitness is an important factor influencing the ability to resist fatigue during RSA exercise. Our results highlighted the usefulness of MASRT, in contrast to WingT, as a specific anaerobic testing procedure to identify the anaerobic energy system contribution during RSA.

  19. Effect of gender on the GH-IGF-I response to anaerobic exercise in young adults.

    Science.gov (United States)

    Eliakim, Alon; Nemet, Dan; Most, Guy; Rakover, Noa; Pantanowitz, Michal; Meckel, Yoav

    2014-12-01

    Exercise-associated effects on the growth hormone-insulin-like growth factor-I (GH-IGF-I) axis were studied, mainly after aerobic exercise. We determined the gender effect on the GH-IGF-I axis response to a standard all-out Wingate anaerobic test (WAnT) in healthy active young adult men and women (men = 12 and women = 16; age range: 24-34 years). Blood samples for GH and IGF-I, key elements of the GH-IGF-I axis, were collected before and 20, 30, 40, and 60 minutes after the beginning of exercise. In addition, we collected postexercise blood lactate levels. Postexercise lactate levels were higher among men; however, this difference did not reach statistical significance (13.8 ± 1.3 vs. 11.1 ± 1.0 mmol·L, respectively; p = 0.1). The WAnT was associated with a significant increase in GH in both genders. However, GH peak was greater among women (10.8 ± 1.8 vs. 5.6 ± 1.4 ng·ml, in women and men, respectively; p Exercise was associated with a significant increase in IGF only among men (from 166.8 ± 8.4 to 186.9 ± 9.3; p anaerobic exercise was associated with a greater and earlier postexercise GH peak in women compared with men. All together, the results suggest anaerobic exercise-related anabolic-type hormonal response.

  20. An on-site test battery to evaluate giant slalom skiing performance.

    Science.gov (United States)

    Andersen, R E; Montgomery, D L; Turcotte, R A

    1990-09-01

    The purpose of this study was to determine if an on-site test battery would distinguish among three levels of giant slalom skiing ability. The test battery consisted of a 20-m shuttle run test, Wingate 60s cycling test, hexagonal obstacle test, high box test, double leg jumping test and vertical jump test. These tests were selected since previous studies have identified aerobic endurance, anaerobic endurance, power and agility as important components for Alpine skiers. Both construct validity and criterion related validity of the test battery were examined using data from 11 club skiers, 14 divisional level skiers, and 9 provincial level skiers. To establish construct validity, univariate F tests examined differences among the three levels of skiers. Significant (P less than 0.05) differences were found between the club skiers and the better skiers (divisional and provincial level) for the following test variables: peak power, mean power, and post-exercise lactate for a 60s Wingate cycle ergometer test, high box test, hexagonal obstacle test, double leg jumping test, and shuttle run test. Criterion related validity was established since there were significant correlations between giant slalom performance time and the hexagonal obstacle test (r = 0.82), high box test (r = -0.80), and double leg jumping (r = -0.86). These data illustrate that an on-site test battery can be used to distinguish among giant slalom Alpine skiers.

  1. Neuro-mechanical and metabolic adjustments to the repeated anaerobic sprint test in professional football players.

    Science.gov (United States)

    Brocherie, Franck; Millet, Gregoire P; Girard, Olivier

    2015-05-01

    This study aimed to determine the neuro-mechanical and metabolic adjustments in the lower limbs induced by the running anaerobic sprint test (the so-called RAST). Eight professional football players performed 6 × 35 m sprints interspersed with 10 s of active recovery on artificial turf with their football shoes. Sprinting mechanics (plantar pressure insoles), root mean square activity of the vastus lateralis (VL), rectus femoris (RF), and biceps femoris (BF) muscles (surface electromyography, EMG) and VL muscle oxygenation (near-infrared spectroscopy) were monitored continuously. Sprint time, contact time and total stride duration increased from the first to the last repetition (+17.4, +20.0 and +16.6 %; all P 0.05), decreased over sprint repetitions and were correlated with the increase in running time (r = -0.82 and -0.90; both P test leads to substantial alterations in stride mechanics and leg-spring behaviour. Our results also strengthen the link between repeated-sprint ability and the change in neuromuscular activation as well as in muscle de- and re-oxygenation rates.

  2. Testing the profitability of Anaerobic Digestion in a large-scale UK dairy farm

    OpenAIRE

    Coz Leniz, Luis Fernando

    2011-01-01

    Anaerobic Digestion (AD) consists in the transformation of any organic non-woody material by micro-organisms into biogas. This biogas, composed of approximately 60 per cent methane can be further burnt and converted into electricity and heat. The UK’s livestock agricultural sector has tremendous potential to take advantage of this technology, as it produces over 150 million tonnes of animal manure annually. This is a commonly used input to feed anaerobic digestion plants. Furthermore, AD brin...

  3. Controversies in the physiological basis of the 'anaerobic threshold' and their implications for clinical cardiopulmonary exercise testing.

    Science.gov (United States)

    Hopker, J G; Jobson, S A; Pandit, J J

    2011-02-01

    This article reviews the notion of the 'anaerobic threshold' in the context of cardiopulmonary exercise testing. Primarily, this is a review of the proposed mechanisms underlying the ventilatory and lactate response to incremental exercise, which is important to the clinical interpretation of an exercise test. Since such tests are often conducted for risk stratification before major surgery, a failure to locate or justify the existence of an anaerobic threshold will have some implications for clinical practice. We also consider alternative endpoints within the exercise response that might be better used to indicate a patient's capacity to cope with the metabolic demands encountered both during and following major surgery. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  4. Creatine co-ingestion with carbohydrate or cinnamon extract provides no added benefit to anaerobic performance.

    Science.gov (United States)

    Islam, Hashim; Yorgason, Nick J; Hazell, Tom J

    2016-09-01

    The insulin response following carbohydrate ingestion enhances creatine transport into muscle. Cinnamon extract is promoted to have insulin-like effects, therefore this study examined if creatine co-ingestion with carbohydrates or cinnamon extract improved anaerobic capacity, muscular strength, and muscular endurance. Active young males (n = 25; 23.7 ± 2.5 y) were stratified into 3 groups: (1) creatine only (CRE); (2) creatine+ 70 g carbohydrate (CHO); or (3) creatine+ 500 mg cinnamon extract (CIN), based on anaerobic capacity (peak power·kg(-1)) and muscular strength at baseline. Three weeks of supplementation consisted of a 5 d loading phase (20 g/d) and a 16 d maintenance phase (5 g/d). Pre- and post-supplementation measures included a 30-s Wingate and a 30-s maximal running test (on a self-propelled treadmill) for anaerobic capacity. Muscular strength was measured as the one-repetition maximum 1-RM for chest, back, quadriceps, hamstrings, and leg press. Additional sets of the number of repetitions performed at 60% 1-RM until fatigue measured muscular endurance. All three groups significantly improved Wingate relative peak power (CRE: 15.4% P = .004; CHO: 14.6% P = .004; CIN: 15.7%, P = .003), and muscular strength for chest (CRE: 6.6% P < .001; CHO: 6.7% P < .001; CIN: 6.4% P < .001), back (CRE: 5.8% P < .001; CHO: 6.4% P < .001; CIN: 8.1% P < .001), and leg press (CRE: 11.7% P = .013; CHO: 10.0% P = .007; CIN: 17.3% P < .001). Only the CRE (10.4%, P = .021) and CIN (15.5%, P < .001) group improved total muscular endurance. No differences existed between groups post-supplementation. These findings demonstrate that three different methods of creatine ingestion lead to similar changes in anaerobic power, strength, and endurance.

  5. Enhancing Short-Term Recovery After High-Intensity Anaerobic Exercise.

    Science.gov (United States)

    Al-Nawaiseh, Ali M; Pritchett, Robert C; Bishop, Philip A

    2016-02-01

    This study examined the effects of antioxidant vitamins, ibuprofen, cold water submersion, and whey protein administered simultaneously on short-term recovery. Competitive athletes (n = 22) performed the protocol in 2 occasions (treatment and control) separated by 15 days in counterbalanced crossover design. Each occasion consisted of morning and afternoon sessions (AM and PM). In each session, participants performed 2 bouts of high-intensity anaerobic cycling separated by 30 minutes of rest. Each bout consisted of 3 Wingate tests (3 × 30-second Wingate tests) with 3 minutes of active recovery in between. Power output, rated perceived exertion (RPE), and pain scores were averaged and compared between the 2 sessions (AM vs. PM) and between the treatment vs. control (4 bouts). Creatine kinase (CK) levels were also measured 24 hours after the AM bout. Power output, CK, muscle soreness, and RPE were measured as recovery indices. Creatine kinase increased (p < 0.001) in both treatment and control 24 hours after the AM session. Performance results in the PM session for treatment/control were 832.5 ± 198.7/813.3 ± 187.6 W for peak power (PP), and 497.85 ± 120.7/486.1 ± 115 W for mean power (MP). Treatment was effective in maintaining MP (p = 0.034) in the PM sessions, but there was no significant effect of treatment on PP (p = 0.193), CK (p = 0.08), pain (p = 0.12), or RPE (p = 0.45). Treatment was helpful in protecting performance, but this was apparently not due to reduced muscle soreness or damage.

  6. The 2.5-minute loaded repeated jump test: evaluating anaerobic capacity in alpine ski racers with loaded countermovement jumps.

    Science.gov (United States)

    Patterson, Carson; Raschner, Christian; Platzer, Hans-Peter

    2014-09-01

    The purposes of this study were to test the reproducibility of the 2.5-minute loaded repeated jump test (LRJT) and to test the effectiveness of general preparation period (GPP) training on anaerobic fitness of elite alpine ski racers with the LRJT. Thirteen male volunteers completed 2 LRJTs to examine reliability. Nine male Austrian elite junior racers were tested in June and October 2009. The LRJT consisted of 60 loaded countermovement jumps (LCMJs) with a loaded barbell equivalent to 40% bodyweight. Before the LRJT, the power (P) of a single LCMJ was determined. Power was calculated from ground reaction forces. The mean P was calculated for the complete test and for each 30-second interval. The interclass correlation coefficients (between 0.88 and 0.99) for main variables of the LRJT demonstrated a high reliability. A repeated-measures analysis of variance indicated that anaerobic capacity was significantly higher in October (p ≤ 0.05). The ski racers' single LCMJ P increased from 37.0 ± 1.2 W·kg to 39.0 ± 1.4 W·kg. The mean P of the total test improved from 33.6 ± 1.2 W·kg to 35.8 ± 1.3 W·kg, but relative effect of fatigue did not change. The GPP training improved the athletes' ability to produce and maintain muscular power. The LRJT is a reliable anaerobic test suitable for all alpine ski racing events because the 60 jumps simulate the approximate number of gates in slalom and giant slalom races and the 2.5 minutes is equivalent to the duration of the longest downhill race.

  7. Feasibility tests for treating shampoo and hair colorant wastewaters using anaerobic processes.

    Science.gov (United States)

    Ahammad, Shaikh Z; Yakubu, A; Dolfing, J; Mota, C; Graham, D W

    2012-01-01

    Wastes from the personal care product (PCP) industry are often high in biodegradable carbon, which makes them amenable to aerobic biological treatment, although process costs are usually high due to aeration inefficiencies, high electricity demand and production of large amounts of sludge. As such, anaerobic treatment technologies are being considered to lower net energy costs by reducing air use and increasing methane production. To assess the amenability of PCP wastes to anaerobic treatment, methane yields and rates were quantified in different anaerobic reactors treating typical PCP wastes, including wastes from shampoo and hair colorant products. Overall, shampoo wastes were more amenable to methanogenesis with almost double the methane yields compared with colour wastes. To assess relevant microbial guilds, qPCR was performed on reactor biomass samples. Methanosaetaceae abundances were always significantly higher than Methanosarcinaceae and Methanomicrobiales abundances (P shampoo wastes, differences cannot be explained by relative microbial abundances and probably result from the presence of inhibiting compounds in hair colorants (e.g., oxidants) at higher levels. Results showed that anaerobic technologies have great potential for treating PCP wastes, but additional work is needed to establish the basis of elevated methane yields and inhibition, especially when colorant wastes are present.

  8. Plasma oxidative stress is induced by single-sprint anaerobic exercise in young cigarette smokers.

    Science.gov (United States)

    Taito, Shunsuke; Sekikawa, Kiyokazu; Oura, Keisuke; Kamikawa, Norimichi; Matsuki, Ryosuke; Kimura, Tatsushi; Takahashi, Makoto; Inamizu, Tsutomu; Hamada, Hironobu

    2013-05-01

    Cigarette smoking increases oxidative stress, which is a risk factor for several diseases. Smoking has also been reported to enhance plasma oxidative stress during strenuous exercise. However, no prior study has examined the changes in plasma oxidative stress after single-sprint anaerobic exercise in cigarette smokers. The purpose of this study was to investigate these changes in young cigarette smokers by measuring reactive oxygen species generation and total antioxidant content. Participants were 15 male smokers (mean age: 25·9 ± 2·9 years) and 18 male non-smokers (mean age: 24·2 ± 4·3 years). Hydroperoxide concentration and biological antioxidant potential (BAP) in plasma were measured at baseline and after the Wingate anaerobic test. A significant interaction between group and time was observed for plasma hydroperoxide concentration (P = 0·037). Plasma hydroperoxide concentration was significantly increased after exercise in both smokers and non-smokers (P = 0·001 and exercise in both groups (both, Panaerobic exercise, which may increase the risk of oxidative damage. © 2012 The Authors Clinical Physiology and Functional Imaging © 2012 Scandinavian Society of Clinical Physiology and Nuclear Medicine.

  9. The effects of an 8-week multicomponent inpatient treatment program on body composition and anaerobic fitness in overweight and obese children and adolescents

    Directory of Open Access Journals (Sweden)

    Karner-Rezek K

    2013-03-01

    Full Text Available Klaus Karner-Rezek,1 Beat Knechtle,2,3 Matthias Fenzl,4 Christian Schlegel,4 Manuela Konrad,5 Thomas Rosemann2 1Private University of the Principality of Liechtenstein, Triesen, Principality of Liechtenstein, 2Institute of General Practice and for Health Services Research, University of Zurich, Zurich, Switzerland; 3Gesundheitszentrum St Gallen, St Gallen, Switzerland; 4Swiss Olympic Medical Center, Medizinisches Zentrum Bad Ragaz, Switzerland; 5University of Applied Sciences JOANNEUM, Bad Gleichenberg, Austria Background: High intensity exercise is considered as an effective means for reducing body fat. The aims of the present study were to investigate (1 whether body mass would be lost and body composition would change and (2 whether variables of anaerobic fitness prior to the intervention period would be related to loss of body mass and changes in body composition in overweight and obese children and adolescents. Methods: A total of 28 children and adolescents (19 boys, 9 girls attended an 8-week multicomponent inpatient program. Caloric intake was based on the subject's weight and a daily energy deficit of ~500 kcal was targeted. At the beginning and at the end of the program, variables of anaerobic fitness were assessed using Wingate tests. Body composition was measured before and after the program using dual-energy X-ray absorptiometry. Results: Body mass decreased by 11.4% ± 1.6% in boys and by 11.0% ± 2.8% in girls (P < 0.001. Fat mass decreased by 23.8% ± 6.1% in boys and by 21.5% ± 5.2% in girls (P < 0.001. The decrease in fat mass was associated with the decrease in body mass in boys (r = 0.54, P = 0.017 but not in girls (P > 0.05. The decrease in body mass and the decrease in fat mass were neither associated with overall energy expenditure nor with the energy deficit in both genders (P > 0.05. Mean power in W/kg increased in the Wingate tests by 95.4% ± 109.1% in boys and by 100.0% ± 119.9% in girls (P < 0.001. Conclusions

  10. The The Effects of Cold Water Immersion on Anaerobic Power, Dynamic Balance and Muscle Activation After a karate kumite fighting in Female Karateka

    Directory of Open Access Journals (Sweden)

    Taher Afshar Nezhad

    2017-10-01

    Full Text Available Many athletes are using specific techniques to minimize fatigue and accelerate recovery processes. Cold water immersion (CWI is one of the most popular interventions used by athletes to potentially return to their pre-fatigue performance level. the purpose of this study was to investigate the effects of CWI on anaerobic performance, balance and muscle activation of female karateka after a simulated match. 15 young female karateka (age: 18.7±1.7 years, body mass: 55.5±6.3 kg, height:165±5.1 cm with at least three years' experience in karate kumite fighting were included in the study. After three round 3-minute competition, participants were grouped into a CWI group (20 min at 12±1°C and a control group (CTL. Anaerobic power (30 s Wingate test, and dynamic balance (Star-Excursion test were measured before the competition and 24 h after intervention. Surface electromyography (EMG was sampled from quadriceps femoris muscles. Peak normalized muscle activation levels and force were identified during maximal isometric test. A significant decrease in the anaerobic performance after the competition was observed for both groups (p<0.05. CWI were effective in enhancing the anaerobic performance after competition compared with the CTL. Dynamic balance decreased for two groups, although CWI resulted in the smallest reduction in balance. There was a significant difference in peak and mean RMS values of the EMG in Rectus Femoris but not Vastus muscles after the CWI intervention when compared to CTL (p<0.05. CWI improve recovery related to dynamic balance and anaerobic performance of karate kumite fighter. It can be concluded that CWI appears to promote muscle activation and reduce fatigue that is related to better performance in 24 hours post intervention.

  11. The Measurement of Maximal (Anaerobic Power Output on a Cycle Ergometer: A Critical Review

    Directory of Open Access Journals (Sweden)

    Tarak Driss

    2013-01-01

    Full Text Available The interests and limits of the different methods and protocols of maximal (anaerobic power ( assessment are reviewed: single all-out tests versus force-velocity tests, isokinetic ergometers versus friction-loaded ergometers, measure of during the acceleration phase or at peak velocity. The effects of training, athletic practice, diet and pharmacological substances upon the production of maximal mechanical power are not discussed in this review mainly focused on the technical (ergometer, crank length, toe clips, methodological (protocols and biological factors (muscle volume, muscle fiber type, age, gender, growth, temperature, chronobiology and fatigue limiting in cycling. Although the validity of the Wingate test is questionable, a large part of the review is dedicated to this test which is currently the all-out cycling test the most often used. The biomechanical characteristics specific of maximal and high speed cycling, the bioenergetics of the all-out cycling exercises and the influence of biochemical factors (acidosis and alkalosis, phosphate ions… are recalled at the beginning of the paper. The basic knowledge concerning the consequences of the force-velocity relationship upon power output, the biomechanics of sub-maximal cycling exercises and the study on the force-velocity relationship in cycling by Dickinson in 1928 are presented in Appendices.

  12. Measurement of pulmonary gas exchange variables and lactic anaerobic capacity during field testing in elite indoor football players.

    Science.gov (United States)

    Angius, L; Cominu, M; Filippi, M; Piredda, C; Migliaccio, G M; Pinna, M; Milia, R; Tocco, F; Concu, A; Crisafulli, A

    2013-10-01

    The aims of this study were: 1) to examine the gas exchange responses of elite indoor football players to a repeated sprint ability (RSA) test; and 2) to verify whether or not the excess of carbon dioxide production (CO2excess) correlates with blood lactate accumulation during RSA field testing. Eleven elite male indoor football players were recruited. A preliminary incremental exercise test on a treadmill was performed to elicit V'O2max. Then, participants underwent an RSA test consisting in a shuttle running through a course with various changes of direction while wearing a portable gas analyzer able to provide values of oxygen uptake, carbon dioxide production, and CO2excess. BLa concentrations during recovery were also measured. The main results were that: 1) during the RSA test subjects did not reached the V'O2max level achieved in the preliminary test; 2) during the RSA test BLa levels were higher compared with the preliminary test; 3) the peak BLa concentration during recovery was significantly correlated with the average CO2excess It was concluded that the RSA test did not appear to be useful to elicit V'O2max. Rather, it seemed suitable to recruit subjects' lactic anaerobic capacity. Moreover, CO2excess appeared suitable for qualitatively estimate BLa accumulation during field testing.

  13. Analysis of production tests in processing the mixture of solid and liquid biologically degradable wastes by anaerobic fermentation

    Directory of Open Access Journals (Sweden)

    Jiří Fryč

    2012-01-01

    Full Text Available This study concerns the analysis of operating anaerobic fermentation systems of agricultural biogas station and implementing a suitable system enabling the use of a mixture of solid and liquid biowaste. The tests made use of liquid substrates commercially offered to biogas station operators. The study evaluates practical measurements at an agricultural biogas station in order to evaluate the biogas production from these substrates and the efficiency of transforming input material to usable energy. The use of such treated substrates for the anaerobic fermentation technology may have a substantial influence on the volume of dosed energy crops. The mixture of input substrates consisting of liquid cattle excrements, silage corn, solid and liquid waste from food processing, animal waste and glycerine water was experimentally validated. This mixture was compared with the operation using liquid cattle excrements and silage corn. It was concluded that the proposed composition of input raw materials makes it possible to increase the production of biogas and el. power. On the other hand, it was identified that the energy content of the input raw materials is not optimally transformed into usable energy. This is why the proposed mixture of input materials with biowaste is not recommended for use at the used proportion.

  14. Anaerobic digestion in combination with 2nd generation ethanol production for maximizing biofuels yield from lignocellulosic biomass – testing in an integrated pilot-scale biorefinery plant

    DEFF Research Database (Denmark)

    Uellendahl, Hinrich; Ahring, Birgitte Kiær

    An integrated biorefinery concept for 2nd generation bioethanol production together with biogas production from the fermentation effluent was tested in pilot-scale. The pilot plant comprised pretreatment, enzymatic hydrolysis, hexose and pentose fermentation into ethanol and anaerobic digestion...... for mesophilic than for thermophilic operation. The effluent from the ethanol fermentation showed no signs of toxicity to the anaerobic microorganisms. Implementation of the biogas production from the fermentation effluent accounted for about 30% higher biofuels yield in the biorefinery compared to a system...... of the fermentation effluent in a UASB (upflow anaerobic sludge blanket) reactor. Operation of the 770 liter UASB reactor was tested under both mesophilic (38ºC) and thermophilic (53ºC) conditions with increasing loading rates of the liquid fraction of the effluent from ethanol fermentation. At an OLR of 3.5 kg...

  15. Comparison of body composition and aerobic and anaerobic performance between competitive cyclists and triathletes

    Directory of Open Access Journals (Sweden)

    Vanderson Luis Moro

    2013-09-01

    Full Text Available The aim of this study was to compare anthropometric characteristics and aerobic and anaerobic fitness between competitive cyclists and triathletes. The sample consisted of 11cyclists and 12 triathletes with experience in competitions. The tests were performed on two different days, with an interval of 48 h between sessions. On the first day,the athletes were submitted to anthropometric assessment (body mass, height,and skinfold thickness and a maximal incremental test to determine maximal oxygen uptake, maximum power, maximum heart rate, maximum lactate, and the first (LL1 and second lactate threshold (LL2. The Wingate test was conducted on the second day to determine peak power, average power, and fatigue index. There were significant difference (p < 0.05, with medium effect size (0.80- 1.5, in mid-thigh skinfold thickness (15.2 ± 6.3 and 10.5 ± 4.8 mm, power at LL1 (195.0 ± 30.9 and 162.7 ± 28.3 W, power at LL2 (247.6 ± 25.0 and 219.7± 37.9 W, and fatigue index (47.2 ± 13.0 and 60.1 ± 16.4% between cyclists and triathletes, respectively. The other variables did not differ between groups. Anthropometric characteristics are similar in triathletes and cyclists. However, cyclists present higher power outputs at the lactate thresholds (LL1 and LL2 and lower fatigue indexes.

  16. Can power and anaerobic capacity reduce according to disordered eating behaviors in cyclists?

    Directory of Open Access Journals (Sweden)

    Leonardo de Sousa Fortes

    Full Text Available Abstract The present study aimed to compare the power, anaerobic capacity (AC and performance in a road bicycle race among cyclists with and without risk of disordered eating behaviors (DEB. The sample was selected in a non-probabilistic way, totaling 69 male road cyclists aged between 19 and 30 years. The Wingate test was used to evaluate peak power (PP and mean power. Time in minutes was adopted to determine performance in a 120-km road cycling race (competitive event. The Eating Attitudes Test (EAT-26 was completed to assess DEBs. The results did not indicate a difference in PP among cyclists with and without risk of DEBs (F (2, 67=3.92; p=0.13. Findings showed a difference in mean power among cyclists with and without risk of DEBs (F (2, 67=36.43; p=0.01. The results revealed a difference in performance in 120-km cycling races among cyclists with and without risk of DEBs (F (2, 67=46.03; p=0.01. It could be concluded that DEBs were associated with a lower mean power and performance in a competitive event among male road cyclists, although the same was not true for PP.

  17. Maximal aerobic and anaerobic exercise responses in children with cerebral palsy.

    Science.gov (United States)

    Balemans, Astrid C J; Van Wely, Leontien; De Heer, Susan J A; Van den Brink, Janneke; De Koning, Jos J; Becher, Jules G; Dallmeijer, Annet J

    2013-03-01

    The objective of this study is to compare the maximal aerobic and anaerobic exercise responses of children with cerebral palsy (CP) by level of motor impairment and in comparison with those of typically developing children (TD). Seventy children with CP, with varying levels of motor impairment (Gross Motor Function Classification System (GMFCS) I-III), and 31 TD performed an incremental continuous maximal aerobic exercise test and a 20-s anaerobic Wingate test on a cycle ergometer. Peak oxygen uptake (V˙O2peak), anaerobic threshold (AT), peak ventilation (V˙Epeak), peak oxygen pulse (peak O2 pulse), peak ventilatory equivalent of oxygen (peak V˙E/V˙O2) and carbon dioxide (peak V˙E/V˙CO2), peak aerobic power output (POpeak), and mean anaerobic power (P20mean) were measured. Isometric leg muscle strength was determined as a secondary outcome. Analysis revealed a lower V˙O2peak for CP (I: 35.5 ± 1.2 (SE); II: 33.9 ± 1.6; III: 29.3 ± 2.5 mL·kg-1·min-1) compared with TD (41.0 ± 1.3, P V˙Epeak and peak O2 pulse were also lower, whereas peak V˙E/V˙CO2 was higher in CP compared with TD (P V˙E/V˙O2 similar between groups. All these variables showed no differences for different motor impairment levels. POpeak was lower for CP (I: 2.4 ± 0.1; II: 1.8 ± 0.1; III: 1.4 ± 0.2 W·kg-1) versus TD (3.0 ± 0.1, P CP (I: 4.6 ± 0.2; II: 3.3 ± 0.2; III: 2.5 ± 0.4 W·kg-1) versus TD (6.4 ± 0.2, P CP have decreased aerobic and anaerobic exercise responses, but decreases in respiratory and aerobic exercise responses were not as severe as predicted by motor impairment. Future research should reveal the role of inactivity on the exercise responses of children with CP and possibilities for improvement through training interventions.

  18. INFLUENCE OF RAMADAN FASTING ON ANAEROBIC PERFORMANCE AND RECOVERY FOLLOWING SHORT TIME HIGH INTENSITY EXERCISE

    Directory of Open Access Journals (Sweden)

    Umid Karli

    2007-12-01

    Full Text Available The aim of this study was to investigate the effects of Ramadan fasting on anaerobic power and capacity and the removal rate of lactate after short time high intensity exercise in power athletes. Ten male elite power athletes (2 wrestlers, 7 sprinters and 1 thrower, aged 20-24 yr, mean age 22.30 ± 1.25 yr participated in this study. The subjects were tested three times [3 days before the beginning of Ramadan (Pre-RF, the last 3 days of Ramadan (End-RF and the last 3 days of the 4th week after the end of Ramadan (After-RF]. Anaerobic power and capacity were measured by using the Wingate Anaerobic Test (WAnT at Pre-RF, End-RF and After- RF. Capillary blood samples for lactate analyses and heart rate recordings were taken at rest, immediately after WAnT and throughout the recovery period. Repeated measures of ANOVA indicated that there were no significant changes in body weight, body mass index, fat free mass, percentage of body fat, daily sleeping time and daily caloric intake associated with Ramadan fasting. No significant changes were found in total body water either, but urinary density measured at End-RF was significantly higher than After-RF. Similarity among peak HR and peak LA values at Pre-RF, End- RF and After-RF demonstrated that cardiovascular and metabolic stress caused by WAnT was not affected by Ramadan fasting. In addition, no influence of Ramadan fasting on anaerobic power and capacity and removal rate of LA from blood following high intensity exercise was observed. The results of this study revealed that if strength-power training is performed regularly and daily food intake, body fluid balance and daily sleeping time are maintained as before Ramadan, Ramadan fasting will not have adverse effects on body composition, anaerobic power and capacity, and LA metabolism during and after high intensity exercise in power athletes

  19. Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals

    Directory of Open Access Journals (Sweden)

    Keisuke Nakamura, Masayoshi Ohira, Yoshiharu Yokokawa, Yuya Nagasawa

    2015-12-01

    Full Text Available Sit-to-stand exercise (STS is a common activity of daily living. The objectives of the present study were: 1 to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs, during incremental sit-to-stand exercise (ISTS with and without arm support compared with an incremental cycle-ergometer (CE test; and 2 to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2 and heart rate at the AT (AT-HR were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey’s post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05; AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05; AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05; and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05. The AT-VO2 values during the ISTS with arm support (18.5 ± 1.9 mL·min-1·kg-1 and the CE test (18.4 ± 1.8 mL·min-1·kg-1 were significantly higher than those during the ISTS without arm support (16.6 ± 1.8 mL·min-1·kg-1; p < 0.05. The AT-HR values during the ISTS with arm support (126 ± 10 bpm and the CE test (126 ± 13 bpm were significantly higher than those during the ISTS without arm support (119 ± 9 bpm; p < 0.05. The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults.

  20. Morphological characteristics, muscle strength, and anaerobic power performance of wheelchair basketball players

    Directory of Open Access Journals (Sweden)

    Sandra Aires Ferreira

    2017-08-01

    Full Text Available The aim of this study was to provide a descriptive analysis of the morphological structure, muscle strength, and anaerobic power performance of the upper limbs of wheelchair basketball athletes. Eleven male players (33.2 ± 10.6 years, 71.8 ± 15.8 kg were submitted to anthropometric measurements and dynamometry (kg, medicine ball throwing (m and wingate arm tests (W. he results showed sitting height (79.7 ± 4.6 cm, relative body fat (20.7 ± 7.6%, handgrip strength and explosive muscle strength (50.1 ± 10.6 kg and 3.9 ± 1.1 m, respectively, as well as peak power (316.8 ± 126.2 W, mean power (160.5 ± 76.5 W and fatigue index (50.4% lower than the performance of other wheelchair basketball athletes. he morphological characteristics and performance of athletes in the present study suggest disadvantages when compared to other wheelchair basketball athletes.

  1. The Effects of High Intensity Interval Training vs Steady State Training on Aerobic and Anaerobic Capacity.

    Science.gov (United States)

    Foster, Carl; Farland, Courtney V; Guidotti, Flavia; Harbin, Michelle; Roberts, Brianna; Schuette, Jeff; Tuuri, Andrew; Doberstein, Scott T; Porcari, John P

    2015-12-01

    High intensity interval training (HIIT) has become an increasingly popular form of exercise due to its potentially large effects on exercise capacity and small time requirement. This study compared the effects of two HIIT protocols vs steady-state training on aerobic and anaerobic capacity following 8-weeks of training. Fifty-five untrained college-aged subjects were randomly assigned to three training groups (3x weekly). Steady-state (n = 19) exercised (cycle ergometer) 20 minutes at 90% of ventilatory threshold (VT). Tabata (n = 21) completed eight intervals of 20s at 170% VO2max/10s rest. Meyer (n = 15) completed 13 sets of 30s (20 min) @ 100% PVO2 max/ 60s recovery, average PO = 90% VT. Each subject did 24 training sessions during 8 weeks. There were significant (p training group, as well as significant increases in peak (+8, + 9 and +5%) & mean (+4, +7 and +6%) power during Wingate testing, but no significant differences between groups. Measures of the enjoyment of the training program indicated that the Tabata protocol was significantly less enjoyable (p training in sedentary young adults. Key pointsSteady state training equivalent to HIIT in untrained studentsMild interval training presents very similar physiologic challenge compared to steady state trainingHIIT (particularly very high intensity variants were less enjoyable than steady state or mild interval trainingEnjoyment of training decreases across the course of an 8 week experimental training program.

  2. The Effects of High Intensity Interval Training vs Steady State Training on Aerobic and Anaerobic Capacity

    Directory of Open Access Journals (Sweden)

    Carl Foster, Courtney V. Farland, Flavia Guidotti, Michelle Harbin, Brianna Roberts, Jeff Schuette, Andrew Tuuri, Scott T. Doberstein, John P. Porcari

    2015-12-01

    Full Text Available High intensity interval training (HIIT has become an increasingly popular form of exercise due to its potentially large effects on exercise capacity and small time requirement. This study compared the effects of two HIIT protocols vs steady-state training on aerobic and anaerobic capacity following 8-weeks of training. Fifty-five untrained college-aged subjects were randomly assigned to three training groups (3x weekly. Steady-state (n = 19 exercised (cycle ergometer 20 minutes at 90% of ventilatory threshold (VT. Tabata (n = 21 completed eight intervals of 20s at 170% VO2max/10s rest. Meyer (n = 15 completed 13 sets of 30s (20 min @ 100% PVO2 max/ 60s recovery, average PO = 90% VT. Each subject did 24 training sessions during 8 weeks. Results: There were significant (p < 0.05 increases in VO2max (+19, +18 and +18% and PPO (+17, +24 and +14% for each training group, as well as significant increases in peak (+8, + 9 and +5% & mean (+4, +7 and +6% power during Wingate testing, but no significant differences between groups. Measures of the enjoyment of the training program indicated that the Tabata protocol was significantly less enjoyable (p < 0.05 than the steady state and Meyer protocols, and that the enjoyment of all protocols declined (p < 0.05 across the duration of the study. The results suggest that although HIIT protocols are time efficient, they are not superior to conventional exercise training in sedentary young adults.

  3. Comparison of three methods to identify the anaerobic threshold during maximal exercise testing in patients with chronic heart failure.

    Science.gov (United States)

    Beckers, Paul J; Possemiers, Nadine M; Van Craenenbroeck, Emeline M; Van Berendoncks, An M; Wuyts, Kurt; Vrints, Christiaan J; Conraads, Viviane M

    2012-02-01

    Exercise training efficiently improves peak oxygen uptake (V˙O2peak) in patients with chronic heart failure. To optimize training-derived benefit, higher exercise intensities are being explored. The correct identification of anaerobic threshold is important to allow safe and effective exercise prescription. During 48 cardiopulmonary exercise tests obtained in patients with chronic heart failure (59.6 ± 11 yrs; left ventricular ejection fraction, 27.9% ± 9%), ventilatory gas analysis findings and lactate measurements were collected. Three technicians independently determined the respiratory compensation point (RCP), the heart rate turning point (HRTP) and the second lactate turning point (LTP2). Thereafter, exercise intensity (target heart rate and workload) was calculated and compared between the three methods applied. Patients had significantly reduced maximal exercise capacity (68% ± 21% of predicted V˙O2peak) and chronotropic incompetence (74% ± 7% of predicted peak heart rate). Heart rate, workload, and V˙O2 at HRTP and at RCP were not different, but at LTP2, these parameters were significantly (P exercise tests, precede the occurrence of LTP2. Target heart rates and workloads used to prescribe tailored exercise training in patients with chronic heart failure based on LTP2 are significantly higher than those derived from HRTP and RCP.

  4. Development of a modified Margaria-Kalamen anaerobic power test for American football athletes.

    Science.gov (United States)

    Hetzler, Ronald K; Vogelpohl, Rachele E; Stickley, Christopher D; Kuramoto, Allison N; Delaura, Mel R; Kimura, Iris F

    2010-04-01

    This study examined a modification of the Margaria-Kalamen test for football players. The football stair climb test (FST) protocol used in this study increased the vertical displacement (20 steps, 3.12 m) so that the mean best time for the test was 2.048 +/- 0.267 seconds. Fifty-eight Division I-A football players volunteered to participate (mean +/- SD age = 20.2 +/- 1.8 yr, height = 184.1 +/- 7.7 cm, weight = 102.5 +/- 19.4 kg). Subjects performed 25 trials with 30 to 40 seconds of rest between trials. Test-retest reliability was determined using 34 subjects by way of intraclass correlation coefficients with a value of 0.73 for peak power and SEM of 105.4 W, indicating an acceptable level of reliability. Subjects were divided into 3 groups by position: linemen (Line), skill, and linebackers (LB). Alpha level was p football players, which, theoretically, should provide more accurate measures of peak power caused by increased vertical displacement and longer duration, resulting in a decreased influence of cheating strategies during test administration. To achieve maximal power in stair climbing tasks, coaches may need to incorporate a greater number of trials or a more intense warm-up than has been previously reported.

  5. Effects of a selective sleep deprivation on subsequent anaerobic performance.

    Science.gov (United States)

    Mougin, F; Bourdin, H; Simon-Rigaud, M L; Didier, J M; Toubin, G; Kantelip, J P

    1996-02-01

    The aim of the study was to investigate the effects of a partial sleep deprivation on a subsequent supramaximal exercise evaluated from the 30 second Wingate test, and on the following recovery. To take into account the active muscle mass, the Wingate test was performed against a constant braking force related to the data of a force-velocity test conducted on a Monark cycle ergometer (Model 814 E with weights) one week before the experimental test. Eight highly trained athletes were enrolled for this study. The changes in ventilatory and metabolic responses were analyzed during and upon completion of physical 30 second exercise, taking place after two nights, in other words, after a reference night and after a night with reduced sleep. Partial sleep deprivation was obtained by delaying bedtime until 3 a.m. The 30 second Wingate test was performed between 9 a.m. and noon the following days, using a Monark ergometer (Model 814 F). The analyses of change scores disclosed that there were no main significant effects for measures of ventilation, lactates and pH(v) levels under the two experimental conditions. The peak power, the mean power output and the peak velocity recorded after partial sleep deprivation were not modified in comparison with the values obtained after the reference night. These findings suggest that acute sleep loss did not contribute to alterations in supramaximal exercise.

  6. Experimental tests on commercial Sweet Product Residue (SPR) as a suitable feed for anaerobic bioenergy (H2+CH4) production.

    Science.gov (United States)

    Malavè, Andrea C Luongo; Fino, Debora; Gómez Camacho, Carlos E; Ruggeri, Bernardo

    2018-01-01

    Food stores can find themselves in the position of having to dispose of different types of products, such as snacks, confectionery, prepackaged food, drinks and others, Sweet Product Residue (SPR), which presents a great opportunity to produce energy through Anaerobic Digestion (AD), due to its high sugar, carbohidrate and fat contents. In order to valorise SPR, this paper takes into consideration the all necessary treatments; owing the fact that the refuses are constitute by an organic part and packaging (plastic, paper and their combinations), a pretreatment able to remove the latter is necessary. SPR refuse was initially subjected to novel pretreatment approach: extrusion at 200atm to remove the packaging, and a Basic Pre-treatment (BP) then tested through a Two-Stage AD (TSAD) process, for H2 and CH4 productions. The experimental results were analysed considering three parameters: Efficiency (ξ), which takes into account the quantity of the energy produced as hydrogen plus methane that the bioreaction is able to extract; Efficacy (η), which takes into account the efficiency of the actual test, compared with that obtained from a reference test carried out with glucose; Energy Sustainability Index (ESI), which takes into account the total amount of energy produced as H2 plus CH4, and the amount of energy consumed to pre-treat the refuse. The effectiveness of the extrusion process in removing the packaging was very high: about 80% of the organic part present in the SPR was recovered. The obtained results have pointed out that SPR is suitable for energy valorization process: ξ=50%, η=0.67 and ESI=24.4, without the need of basic pre-treatment. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. The effect of combined supplementation of carbohydrates and creatine on anaerobic performance

    Directory of Open Access Journals (Sweden)

    AS Theodorou

    2017-02-01

    Full Text Available The purpose of the study was to examine the effect of creatine (Cr supplementation on anaerobic performance when ingesting creatine and carbohydrates (CHO together. Twenty male physical education students comprised the two experimental (CR and CRCHO and one control (CON groups of the study. All groups performed three 30 s anaerobic Wingate tests (AWTs interspersed with 6 minutes of recovery. The CR group (n = 7 ingested 5 g of Cr 5 times per day for 4 days. Subjects in the CRCHO group (n = 6 ingested the same quantity but additionally after each 5 g dose of Cr consumed 500 ml of a commercially available energy drink containing 100 g of simple sugars. Over all three AWTs average mean power improved significantly compared to baseline for the CR group (5.51% but not for the CRCHO group (3.06%. Mean power for the second AWT was improved following the acute loading for the CR group only (4.54% and for the third AWT for both CR (8.49% and CRCHO (5.75% groups. Over all three AWTs a significant change was recorded in average peak power following the acute loading for the CR group (8.26% but not for the CRCHO group (4.11%. Peak power was significantly improved following the loading only for the CR group during the third AWT (19.79%. No changes in AWT performance were recorded for the CON group after intervention. The findings of the present study suggest that ingesting creatine together with carbohydrates will not further improve performance compared to the ingestion of creatine only.

  8. Acute Effects of Peristaltic Pneumatic Compression on Repeated Anaerobic Exercise Performance and Blood Lactate Clearance.

    Science.gov (United States)

    Martin, Jeffrey S; Friedenreich, Zachary D; Borges, Alexandra R; Roberts, Michael D

    2015-10-01

    External pneumatic compression (EPC) use in athletics is increasing. However, there is a paucity of evidence supporting the effectiveness of EPC in aiding recovery and performance. We sought to determine the efficacy of EPC for acute recovery of anaerobic power and lactate clearance following a fatigue protocol. Fourteen (n = 14; women = 7 and men = 7), apparently healthy, active subjects (aged 22.73 ± 4.05 years) were enrolled in this randomized crossover design study. After familiarization sessions, subjects completed 2 study trials separated by 3-7 days. Trials consisted of a fatigue protocol (two 30-second Wingate anaerobic tests (WAnTs) on a cycle ergometer separated by 3 minutes of rest), 30 minutes of treatment with EPC or sham, and, finally, a single 30-second WAnT. A peristaltic pulse EPC device was used with target inflation pressures of ∼70 mm Hg applied to the lower limbs. Peak power (PkP), average power (AP), and the fatigue index (FI) were recorded for each WAnT. Moreover, blood lactate concentration (BLa) was evaluated at baseline and at regular intervals during recovery (5, 15, 25, and 35 minutes postfatigue protocol). No significant differences in PkP, AP, and FI were observed. However, BLa was significantly lower at 25 and 35 minutes of recovery (8.91 ± 3.12 vs. 10.66 ± 3.44 mmol·L(-1) [p = 0.021] and 6.44 ± 2.14 vs. 7.89 ± 2.37 mmol·L(-1) [p = 0.006] for EPC vs. sham, respectively). Application of EPC during recovery may be a viable alternative when "inactive" recovery is desirable.

  9. The utility of the BANA test for monitoring anaerobic infections due to spirochetes (Treponema denticola) in periodontal disease.

    Science.gov (United States)

    Loesche, W J; Giordano, J; Hujoel, P P

    1990-10-01

    Treponema denticola, Porphyromonas gingivalis, and Bacteroides forsythus each possesses an enzyme(s) that hydrolyzes the synthetic substrate benzoyl-DL-arginine-naphthylamide (BANA). The presence of these organisms in a subgingival plaque sample can be determined by the ability of the plaque to hydrolyze BANA. In the present study, we describe the usefulness of the BANA test at various stages of a clinical trial of the efficacy of metronidazole in the treatment of periodontal disease. A BANA-positive test was significantly associated with high levels and proportions of spirochetes in the plaque, so that it provided information comparable with that which could be obtained by a microscopic examination of the plaque. Patients with such anaerobic spirochetal infections were randomly assigned to a group receiving either metronidazole or placebo (250 mg, three times a day) for one week and whose teeth were scaled and root-planed. The advantages of the decision that metronidazole be used were apparent from the comparison with the results obtained in the patients who received only the scaling and root planing. The initially BANA-positive teeth in the patients treated with metronidazole, scaling, and root planing gained attachment and exhibited a significant reduction in the need for periodontal surgery, when compared with the BANA-positive teeth in the patients who received only placebo, scaling, and root planing. After the conclusion of this therapy, those teeth with persistent BANA-positive plaques had significantly higher proportions and levels of spirochetes than did the teeth with BANA-negative plaques.(ABSTRACT TRUNCATED AT 250 WORDS)

  10. Validity and Reproducibility of an Incremental Sit-To-Stand Exercise Test for Evaluating Anaerobic Threshold in Young, Healthy Individuals.

    Science.gov (United States)

    Nakamura, Keisuke; Ohira, Masayoshi; Yokokawa, Yoshiharu; Nagasawa, Yuya

    2015-12-01

    Sit-to-stand exercise (STS) is a common activity of daily living. The objectives of the present study were: 1) to assess the validity of aerobic fitness measurements based on anaerobic thresholds (ATs), during incremental sit-to-stand exercise (ISTS) with and without arm support compared with an incremental cycle-ergometer (CE) test; and 2) to examine the reproducibility of the AT measured during the ISTSs. Twenty-six healthy individuals randomly performed the ISTS and CE test. Oxygen uptakes at the AT (AT-VO2) and heart rate at the AT (AT-HR) were determined during the ISTSs and CE test, and repeated-measures analyses of variance and Tukey's post-hoc test were used to evaluate the differences between these variables. Pearson correlation coefficients were used to assess the strength of the relationship between AT-VO2 and AT-HR during the ISTSs and CE test. Data analysis yielded the following correlations: AT-VO2 during the ISTS with arm support and the CE test, r = 0.77 (p < 0.05); AT-VO2 during the ISTS without arm support and the CE test, r = 0.70 (p < 0.05); AT-HR during the ISTS with arm support and the CE test, r = 0.80 (p < 0.05); and AT-HR during the ISTS without arm support and the CE test, r = 0.66 (p < 0.05). The AT-VO2 values during the ISTS with arm support (18.5 ± 1.9 mL·min(-1)·kg(-1)) and the CE test (18.4 ± 1.8 mL·min(-1)·kg(-1)) were significantly higher than those during the ISTS without arm support (16.6 ± 1.8 mL·min(-1)·kg(-1); p < 0.05). The AT-HR values during the ISTS with arm support (126 ± 10 bpm) and the CE test (126 ± 13 bpm) were significantly higher than those during the ISTS without arm support (119 ± 9 bpm; p < 0.05). The ISTS with arm support may provide a cardiopulmonary function load equivalent to the CE test; therefore, it is a potentially valid test for evaluating AT-VO2 and AT-HR in healthy, young adults. Key pointsThe ISTS is a simple test that varies only according to the frequency of standing up, and requires only

  11. Relationships between the yo-yo intermittent recovery test and anaerobic performance tests in adolescent handball players.

    Science.gov (United States)

    Hermassi, Souhail; Aouadi, Ridha; Khalifa, Riadh; van den Tillaar, Roland; Shephard, Roy J; Chelly, Mohamed Souhaiel

    2015-03-29

    The aim of the present study was to investigate relationships between a performance index derived from the Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1) and other measures of physical performance and skill in handball players. The other measures considered included peak muscular power of the lower limbs (Wpeak), jumping ability (squat and counter-movement jumps (SJ, CMJ), a handball skill test and the average sprinting velocities over the first step (VS) and the first 5 m (V5m). Test scores for 25 male national-level adolescent players (age: 17.2 ± 0.7 years) averaged 4.83 ± 0.34 m·s(-1) (maximal velocity reached at the Yo-Yo IR1); 917 ± 105 Watt, 12.7 ± 3 W·kg(-1) (Wpeak); 3.41 ± 0.5 m·s(-1) and 6.03 ± 0.6 m·s(-1) (sprint velocities for Vs and V5m respectively) and 10.3 ± 1 s (handball skill test). Yo-Yo IR1 test scores showed statistically significant correlations with all of the variables examined: Wpeak (W and W·kg(-1)) r = 0.80 and 0.65, respectively, p≤0.001); sprinting velocities (r = 0.73 and 0.71 for VS and V5m respectively; p≤0.001); jumping performance (SJ: r = 0.60, p≤0.001; CMJ: r= 0.66, p≤0.001) and the handball skill test (r = 0.71; p≤0.001). We concluded that the Yo-Yo test score showed a sufficient correlation with other potential means of assessing handball players, and that intra-individual changes of Yo-Yo IR1 score could provide a useful composite index of the response to training or rehabilitation, although correlations lack sufficient precision to help in players' selection.

  12. Viscosity evolution of anaerobic granular sludge

    NARCIS (Netherlands)

    Pevere, A.; Guibaud, G.; Hullebusch, van E.D.; Lens, P.N.L.; Baudu, M.

    2006-01-01

    The evolution of the apparent viscosity at steady shear rate of sieved anaerobic granular sludge (20¿315 ¿m diameter) sampled from different full-scale anaerobic reactors was recorded using rotation tests. The ¿limit viscosity¿ of sieved anaerobic granular sludge was determined from the apparent

  13. Relationships Between the Yo-Yo Intermittent Recovery Test and Anaerobic Performance Tests in Adolescent Handball Players

    Directory of Open Access Journals (Sweden)

    Hermassi Souhail

    2015-03-01

    Full Text Available The aim of the present study was to investigate relationships between a performance index derived from the Yo-Yo Intermittent Recovery Test level 1 (Yo-Yo IR1 and other measures of physical performance and skill in handball players. The other measures considered included peak muscular power of the lower limbs (Wpeak, jumping ability (squat and counter-movement jumps (SJ, CMJ, a handball skill test and the average sprinting velocities over the first step (VS and the first 5 m (V5m. Test scores for 25 male national-level adolescent players (age: 17.2 ± 0.7 years averaged 4.83 ± 0.34 m·s-1 (maximal velocity reached at the Yo-Yo IR1; 917 ± 105 Watt, 12.7 ± 3 W·kg-1 (Wpeak; 3.41 ± 0.5 m·s-1 and 6.03 ± 0.6 m·s-1 (sprint velocities for Vs and V5m respectively and 10.3 ± 1 s (handball skill test. Yo-Yo IR1 test scores showed statistically significant correlations with all of the variables examined: Wpeak (W and W·kg-1 r = 0.80 and 0.65, respectively, p≤0.001; sprinting velocities (r = 0.73 and 0.71 for VS and V5m respectively; p≤0.001; jumping performance (SJ: r = 0.60, p≤0.001; CMJ: r= 0.66, p≤0.001 and the handball skill test (r = 0.71; p≤0.001. We concluded that the Yo-Yo test score showed a sufficient correlation with other potential means of assessing handball players, and that intra-individual changes of Yo-Yo IR1 score could provide a useful composite index of the response to training or rehabilitation, although correlations lack sufficient precision to help in players’ selection.

  14. Influência da aptidão aeróbia no running anaerobic sprint test (RAST

    Directory of Open Access Journals (Sweden)

    Vitor Luiz de Andrade

    2013-09-01

    Full Text Available O objetivo do estudo foi verificar a possível influência de diferentes níveis de aptidão aeróbia (VO2MAX sobre os parâmetros do running anaerobic sprint test (RAST. Para isso, 38 indivíduos (Idade = 18,1±2,5 anos, Estatura = 173±1 cm e Massa corporal = 65,1±6,5 kg foram classificados em dois grupos, baixa e elevada aptidão aeróbias (GBA: n=22 e GEA: n=16. O VO2MAX foi determinado por um esforço incremental em esteira rolante até a exaustão voluntária. O RAST foi composto de seis esforços máximos de 35m separados por 10s de intervalo passivo. O VO2MAX foi significativamente diferente entre os grupos (GBA = 51,7±1,9 mL.kg-1.min-1; GEA = 58,6±3,1 mL.kg-1.min-1. A potência média (PM foi significativamente superior no grupo GBA (552,7±132,1 W em relação ao grupo GEA (463,6±132,8 W. O impulso (ImP foi significativamente correlacionado com o VO2MAX no GEA. Pode-se concluir que há um indicativo que o metabolismo aeróbio exerce uma influência na realização do RAST.

  15. Desempenho da potência anaeróbia em atletas de elite do mountain bike submetidos à suplementação aguda com creatina Anaerobic power output of elite off-road cyclists with acute oral creatine supplementation

    Directory of Open Access Journals (Sweden)

    Guilherme Eckhardt Molina

    2009-10-01

    Full Text Available Com o objetivo de investigar os efeitos da suplementação aguda com creatina no desempenho da potência anaeróbia de atletas de elite do mountain bike, 20 atletas em período básico do macrociclo de treinamento foram distribuídos aleatoriamente (duplo-cego em dois grupos: placebo (PLA, n = 10 e creatina (CRE, n = 10. Foram avaliados quanto à composição corporal (pesagem hidrostática e potência anaeróbia (teste de Wingate - TW antes (PRÉ e depois (PÓS de sete dias de suplementação. A creatina ou maltodextrina foi usada em três doses diárias de 0,3g/kg de massa corporal diluídos em meio líquido adoçado. Não foram observadas diferenças significativas nas variáveis morfológicas após sete dias de suplementação (PRÉ x PÓS, e os grupos não diferiram apesar da variação percentual (Δ% contrária (positiva para o grupo CRE e negativa para o PLA. A potência anaeróbia pico (PP e o instante da potência pico (IPP aumentaram e o índice de fadiga diminuiu do PRÉ para o PÓS-testes no grupo CRE, enquanto que o grupo PLA não apresentou diferenças significantes. A PP apresentou forte tendência em ser maior e o IPP foi maior no grupo CRE comparado com o PLA. Conclui-se que existem evidências de que a suplementação com creatina (0,3g/kg em curto prazo (sete dias pode retardar o IPP (CRE 3,0 ± 0,5/3,6 ± 0,8 Δ%= 20% no teste de Wingate em atletas de elite do mountain bike, sugerindo que a suplementação com creatina pode melhorar o desempenho físico quanto à potência anaeróbia durante o trabalho de alta intensidade e curta duração.In order to investigate the effect of a high dose, acute oral creatine supplementation on anaerobic power of male off-road cyclists, twenty elite athletes training at the basic period were randomly (double-blind assigned into 2 groups: placebo (PLA n=10 and creatine (CRE n=10. They were submitted to a body composition evaluation (underwater weighting and Wingate Anaerobic Test (TW before

  16. Ability to work in anaerobic condition is associated with physical performance on the six-minute walk test in older patients receiving cardiac rehabilitation.

    Science.gov (United States)

    Pasquini, Guido; Vannetti, Federica; Molino-Lova, Raffaele

    2015-05-01

    During maximal incremental exercise, the ability to work in the anaerobic condition, expressed by the respiratory exchange ratio, is associated with physical performance. Further, peak respiratory exchange ratio is regarded as the best non-invasive measure of a patient's actual exercise effort. This study examined whether ability to work in the anaerobic condition is also associated with physical performance in submaximal constant work rate exercise. A total of 75 older patients (51 men, 24 women), mean age 71.1 years (standard deviation 6.7 years), who had recently undergone cardiac surgery, performed cardiopulmonary exercise testing in a 6-min walk test before and after rehabilitation. The distance walked, steady-state oxygen uptake, carbon dioxide output and respiratory exchange ratio increased significantly after rehabilitation (p anaerobic condition is associated with physical performance in submaximal constant work rate exercises. Thus the steady-state respiratory exchange ratio might be regarded as a measure of the patient's actual exercise effort. This information may prove useful in customizing exercise prescription and assessing the effects of rehabilitation.

  17. Metabolic and cardiorespiratory responses in young oarsmen during prolonged exercise tests on a rowing ergometer at power outputs corresponding to two concepts of anaerobic threshold.

    Science.gov (United States)

    Bourgois, J; Vrijens, J

    1998-01-01

    A group of ten young experienced oarsmen [mean age 17.5 (SD 1.7) years, height 182.5 (SD 5.9) cm, body mass 77.0 (SEM 10.6) kg] exercised in a progressive incremental test (PIE: 50W x 3 min[-1]) on a rowing ergometer to determine the power output corresponding to the 4 mmol lactate x l(-1) anaerobic threshold (AT4) and the individual anaerobic threshold (IAT). Within 10 days they performed at random two 30-min prolonged exercise tests (PET) at power outputs corresponding to AT4 and IAT to demonstrate whether or not a steady-state blood lactate concentration [La-]b could be maintained. Oxygen uptake (VO2), heart rate (HR) and [La-]b were measured. The PIE revealed significant lower values at IAT compared to AT4 for power output (P concepts of anaerobic threshold gave different information about submaximal endurance capacity. Only IAT represented on average [La-]ss. It is suggested that more research is needed to elicit optimal guidelines for the intensity of endurance training.

  18. The Acute Effects of Static Stretching Compared to Dynamic Stretching with and without an Active Warm up on Anaerobic Performance.

    Science.gov (United States)

    Kendall, Bradley J

    2017-01-01

    The Wingate Anaerobic Test (WAnT) has been used in many studies to determine anaerobic performance. However, there has been poor reporting of warm-up protocols and limited consistency between warm-up methods that have been used. With the WAnT being such a commonly-used test, consistency in warm-up methods is essential in order to compare results across studies. Therefore, this study was designed to compare how static stretching, dynamic stretching, and an active warm-up affect WAnT performance. Ten recreationally active participants (5 males, 5 females) with a mean (SD) age of 23.3 (0.7) volunteered for this study. Subjects were randomized to a specific order of five warm-up protocols, which were performed on individual days followed by a WAnT. Peak power, mean power, power drop, and fatigue index were compared for each trial using a repeated measures ANOVA. For peak power, results revealed that warm-up protocol had a significant effect, F(4,36) = 3.90, p = .01, partial η(2) = .302. It was hypothesized that the dynamic stretching would lead to greater peak power than the static stretching protocol. However, results of post hoc analyses failed to detect a significant difference (p =.065). For the other measured variables no significant differences were found. The findings from this study suggest that warm-up protocols may have significantly different impacts on peak power during the WAnT. Additional research should use larger sample sizes and further explore these warm-up protocols. Developing a standardized warm-up protocol for the WAnT may improve consistency between studies.

  19. Can a 15m-overground wheelchair sprint be used to assess wheelchair-specific anaerobic work capacity?

    Science.gov (United States)

    van der Scheer, Jan W; de Groot, Sonja; Vegter, Riemer J K; Veeger, Dirkjan H E J; van der Woude, Lucas H V

    2014-04-01

    To evaluate whether outcomes based on stopwatch time and power output (PO) over a 15m-overground wheelchair sprint test can be used to assess wheelchair-specific anaerobic work capacity, by studying their relationship with outcomes on a Wingate-based 30s-wheelchair ergometer sprint (WAnT). Able-bodied persons (N=19, 10 men, aged 18-26 y) performed a 15m overground sprint test in an instrumented wheelchair and a WAnT. 15m-outcomes were based on stopwatch time (time and mean velocity over 15m) and on PO (primary outcome: highest mean unilateral PO over successive 5s-intervals (P5-15m)). WAnT-outcomes were mean unilateral PO over 30s and the highest mean unilateral PO over successive 5s-intervals. Correlation coefficients (Pearson's r) and coefficients of determination (R(2)) were calculated between 15m-sprint outcomes and WAnT-outcomes. Time over 15m (7.2s (± 1.0)) was weakly related to WAnT-outcomes (r=-0.61 and -0.60, R(2)=0.38 and 0.36, pwheel can be implemented in rehabilitation practice and research settings when WAnT equipment is not available, although care is needed when interpreting P5-15m as an outcome of anaerobic work capacity given that it seems more skill-dependent than the WAnT. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. Comparação de dois testes indiretos anaeróbicos em futebolistas profissionais e suas correlações com o desempenho aeróbico

    Directory of Open Access Journals (Sweden)

    Saulo Fernandes Melo de Oliveira

    Full Text Available Resumo Para comparar e correlacionar dois testes anaeróbicos com a potência aeróbica nove jogadores de futebol passaram por avaliações ao longo de três dias: Wingate (dia 1, yo-yo intermitente (dia 2 e running anaerobic sprint (RAST, dia 3. Foram consideradas a potência máxima absoluta e relativa (Pmax, potência média absoluta e relativa (Pmed, o índice de fadiga (IF% e o VO2máx. Apenas a Pmed relativa foi diferente entre os testes (p < 0.05. Foram verificadas associações entre a Pmax e Pmed absolutas com o VO2máx (r= -0,69, p < 0,05; r= -0,81; p < 0,05 no Wingate; entre Pmax absoluta e o IF% com o VO2máx (r= -0,83, p < 0,01; r= -0,86; p < 0,01 no RAST. Conclui-se que apenas o RAST possui associações com a capacidade aeróbica.

  1. [SLEEP OF ELITE YOUNG ATHLETE AT THE ACADEMY FOR SPORT EXCELLENCE AT THE WINGATE INSTITUTE].

    Science.gov (United States)

    Navot Mintzer, Dalya; Shargal, Eyal; Fuxman, Yair; Wissblat, Dorit; Baharav, Anda

    2016-06-01

    Sleep duration and quality have a critical role in cognitive and athletic performances. A relationship was demonstrated between sleep deprivation, reduced performance and elevated injury risk. The recommended sleep duration for teenagers is at least 9 hours a day but most sleep less. To estimate sleep duration among elite adolescent athletes at the Academy for Sport Excellence at the Wingate Institute, by quantifying the changes after joining the academy and the relation to school performances and the usage of medical services. Data from medical records, including sleep screening questionnaires and a number of the athletes' medical appointments were analyzed. Athletes reported that sleep duration was less than recommended before joining the academy. After joining the academy the average sleep duration decreased (7.37 vs 7.7 hours, P = 0.05) and daytime sleepiness was elevated (13/24 v 11/24 Epworth-Sleepiness-Scale (ESS), P = 0.002). Correlations between changes in sleep duration and changes in school achievements before and after joining the academy were demonstrated (P = 0.027). No correlation was found between sleep duration at the academy and usage of medical services. Elite adolescent athletes do not sleep enough and are tired during the day. Reduction in sleep duration and elevation in sleepiness were observed with the transition to practice, study and life at the Academy for Sport Excellence. In accordance with previous studies, our findings showed elite young athletes are in a state of continuous sleep deprivation that interferes with their school achievements. Further research is needed to evaluate the importance of sleep duration and quality in performance for the health of young athletes.

  2. The Effects of Low Dose Buccal Administered Caffeine on RPE and Pain during an Upper Body Muscle Endurance Test and Lower Body Anaerobic Test

    Science.gov (United States)

    Bellar, David M.; Judge, Lawrence W.; Kamimori, Gary H.; Glickman, Ellen L.

    2012-01-01

    To date there have been a number of studies that have assessed the effects of caffeine on Rated Perceived Exertion (RPE) and Pain Scale scores during continuous exercise. Presently there is little information about the effects of caffeine on RPE and Pain Scale scores during short term, anaerobic and muscle endurance activity. The purpose of the…

  3. Supplementation of Acqua Lete® (Bicarbonate Calcic Mineral Water improves hydration status in athletes after short term anaerobic exercise

    Directory of Open Access Journals (Sweden)

    Brancaccio Paola

    2012-07-01

    Full Text Available Abstract Background Experimental studies suggest that mineral waters with high concentrations of calcium and bicarbonate can impact acid–base balance. The purpose of this study was to test the effect on acid–base balance and specific urine gravity, of a bicarbonate calcic mineral water (Acqua Lete® compared to a minimally mineralized water. Methods 88 amateur male athletes underwent two experimental trials with a modified Wingate test: the first was carried out without hydration (Control Test, Test C, n = 88; the second was carried out after one week of controlled hydration (Test with hydration, Test H, n = 88, with 1.5 L/day of a very low mineral content water (Group A, n = 44 or 1.5 L/day of Acqua Lete® (Group B, n = 44. Measure of body temperature, bioimpedance analysis, muscular ultrasound, and urinalysis were taken before (t0, immediately after (t1, 5’ (t2, and 30’ (t3 after exercise. Results Hydration results in a decreased core temperature; muscular ultrasound showed increased muscle thickness after exercise related to content of body water. Regarding urinalysis, in test H, we found in both groups after exercise a significant decrease of specific urine gravity with significantly lower levels in Group B. We also found a significant increase of pH in the same Group B. Conclusions In conclusion all the athletes hydrated with Acqua Lete® showed a positive impact on hydration status after anaerobic exercise with significant decrease of specific urine gravity and a positive effect on pH.

  4. Supplementation of Acqua Lete® (Bicarbonate Calcic Mineral Water) improves hydration status in athletes after short term anaerobic exercise.

    Science.gov (United States)

    Brancaccio, Paola; Limongelli, Francesco Mario; Paolillo, Iride; D'Aponte, Antonio; Donnarumma, Vincenzo; Rastrelli, Luca

    2012-07-26

    Experimental studies suggest that mineral waters with high concentrations of calcium and bicarbonate can impact acid-base balance. The purpose of this study was to test the effect on acid-base balance and specific urine gravity, of a bicarbonate calcic mineral water (Acqua Lete®) compared to a minimally mineralized water. 88 amateur male athletes underwent two experimental trials with a modified Wingate test: the first was carried out without hydration (Control Test, Test C, n = 88); the second was carried out after one week of controlled hydration (Test with hydration, Test H, n = 88), with 1.5 L/day of a very low mineral content water (Group A, n = 44) or 1.5 L/day of Acqua Lete® (Group B, n = 44). Measure of body temperature, bioimpedance analysis, muscular ultrasound, and urinalysis were taken before (t0), immediately after (t1), 5' (t2), and 30' (t3) after exercise. Hydration results in a decreased core temperature; muscular ultrasound showed increased muscle thickness after exercise related to content of body water. Regarding urinalysis, in test H, we found in both groups after exercise a significant decrease of specific urine gravity with significantly lower levels in Group B. We also found a significant increase of pH in the same Group B. In conclusion all the athletes hydrated with Acqua Lete® showed a positive impact on hydration status after anaerobic exercise with significant decrease of specific urine gravity and a positive effect on pH.

  5. Reliability and validity of short-term performance tests for wheelchair-using children and adolescents with cerebral palsy.

    Science.gov (United States)

    Verschuren, Olaf; Zwinkels, Maremka; Obeid, Joyce; Kerkhof, Nicky; Ketelaar, Marjolijn; Takken, Tim

    2013-12-01

    To investigate the test-retest reproducibility of the Muscle Power Sprint Test (MPST), the 10 × 5-m sprint test, and the arm-cranking Wingate Anaerobic Test (WAnT) in children and adolescents with cerebral palsy (CP). A secondary objective was to assess the construct validity of the MPST. Twenty-three participants with spastic CP (mean age 13 y 3 mo, range 7-18 y, SD 3.6 y; 18 males, five females, two classified as having spastic unilateral CP, 21 as having spastic bilateral CP) using a manual wheelchair for at least part of the day were recruited and tested in different rehabilitation settings in the Netherlands. Participants were classified as in Gross Motor Function Classification System Expanded and Revised (GMFCS-E&R) levels III and IV. Intraclass correlation coefficients (range 0.93-0.99; 95% confidence interval 0.82-1.0) for all variables indicated highly acceptable reproducibility. Limits of agreement analysis revealed satisfactory levels of agreement. The MPST variables demonstrated very strong significant positive correlations for peak power and mean power from both tests (peak power: r=0.91, pagility in adolescents with spastic CP who self-propel a manual wheelchair. The MPST has been shown to be a valid test to measure anaerobic performance in this population. © 2013 Mac Keith Press.

  6. Anaerobic Thermophiles

    Directory of Open Access Journals (Sweden)

    Francesco Canganella

    2014-02-01

    Full Text Available The term “extremophile” was introduced to describe any organism capable of living and growing under extreme conditions. With the further development of studies on microbial ecology and taxonomy, a variety of “extreme” environments have been found and an increasing number of extremophiles are being described. Extremophiles have also been investigated as far as regarding the search for life on other planets and even evaluating the hypothesis that life on Earth originally came from space. The first extreme environments to be largely investigated were those characterized by elevated temperatures. The naturally “hot environments” on Earth range from solar heated surface soils and water with temperatures up to 65 °C, subterranean sites such as oil reserves and terrestrial geothermal with temperatures ranging from slightly above ambient to above 100 °C, to submarine hydrothermal systems with temperatures exceeding 300 °C. There are also human-made environments with elevated temperatures such as compost piles, slag heaps, industrial processes and water heaters. Thermophilic anaerobic microorganisms have been known for a long time, but scientists have often resisted the belief that some organisms do not only survive at high temperatures, but actually thrive under those hot conditions. They are perhaps one of the most interesting varieties of extremophilic organisms. These microorganisms can thrive at temperatures over 50 °C and, based on their optimal temperature, anaerobic thermophiles can be subdivided into three main groups: thermophiles with an optimal temperature between 50 °C and 64 °C and a maximum at 70 °C, extreme thermophiles with an optimal temperature between 65 °C and 80 °C, and finally hyperthermophiles with an optimal temperature above 80 °C and a maximum above 90 °C. The finding of novel extremely thermophilic and hyperthermophilic anaerobic bacteria in recent years, and the fact that a large fraction of them belong

  7. Sprint Interval Training Improves Aerobic and Anaerobic Power in Trained Female Futsal Players

    Directory of Open Access Journals (Sweden)

    Fatemeh Beyranvand

    2017-04-01

    Full Text Available Background: Various sprint interval training (SIT programs have been used with athletes from a wide range of sports to evaluate its effects on physiological and performance adaptations. However, information regarding the effect of a short period of SIT on physiological adaptations of trained female futsal players is limited. Objective: This study evaluated the influence of sport specific SIT on anaerobic power and aerobic power in trained female futsal players. Method: Several aspects of V̇O2max and Wingate-based power were measured after SIT program performed for 4 weeks. Following pre-test, 16 trained female futsal players (V̇O2max = 41.21 ± 3.35 ml.kg-1.min-1 were randomized to either an intense exercise training consisting of sets of 5×40 meter maximum sprint efforts interspersed by a 10-second rest between sprints (3,4,5,6 sets/session from 1st to 4th week respectively with 3 minutes of recovery between sets, performed two sessions a week over 4 weeks (n=8 or a usual training control group (n=8. Results: Significant (except as shown improvements (p < 0.05 after SIT were seen in: V̇O2max (5.8%, vV̇O2max (6%, V̇O2/HR (6.5%, peak power output (PPO (7.6%, and mean power output (MPO (14.9%, but no significant change was found in Heart rate at V̇O2max. Also, no significant enhancement in mentioned variables was found in the CON group. Conclusion: Present results indicate 4 weeks of sprint interval training program with low volume is associated with improvements in V̇O2max, vV̇O2max, V̇O2/HR, PPO, and MPO in trained female futsal players.

  8. Effect of different recovery modalities on anaerobic power in off-road cyclists

    Directory of Open Access Journals (Sweden)

    V Bielik

    2010-03-01

    Full Text Available Despite massage being widely used by athletes, opinions its effects on performance recovery differ. The aim of the study was reveal the effects of passive recovery (PR, sport massage (SM and active recovery (AR after series of Wingate anaerobic test (WAnT on peak power (PP and mean power (MP. Eleven junior off-road cyclists performed warm up on the cycle ergometer followed by 3 bouts of WAnT interspersed with 4 min rest. After 20 min of PR, SM or AR subjects performed fourth WAnT in random order one week apart. There was no significant difference in PP between PR and SM (875.5 ± 56.2 vs. 921.6 ± 50.8 W but significant difference between PR and AR (875.5 ± 56.2 vs. 970.2 ± 68.9 W; p<0.05. Significant differences were also found for MP between PR and AR (678.4 ± 45.2 vs. 746.1 ± 47.0 W; p<0.05 but not for PR and SM (678.4 ± 45.2 vs. 714.6 ± 32.8 W. Blood lactate concentration after intervention was significantly different only between trials with PR and AR (13.3 ± 2.9 vs. 7.4 ± 3.9 mmol•L-1; p<0.01 and between SM and AR (14.6 ± 3.0 vs. 7.4 ± 3.9 mmol•L-1; p<0.01. A one–way ANOVA with repeated measure indicated that AR presents better modality in reducing blood lactate or renewal PP and MP than PR and SM.

  9. Increased oxidative stress and anaerobic energy release, but blunted Thr172-AMPKα phosphorylation, in response to sprint exercise in severe acute hypoxia in humans.

    Science.gov (United States)

    Morales-Alamo, David; Ponce-González, Jesús Gustavo; Guadalupe-Grau, Amelia; Rodríguez-García, Lorena; Santana, Alfredo; Cusso, Maria Roser; Guerrero, Mario; Guerra, Borja; Dorado, Cecilia; Calbet, José A L

    2012-09-01

    AMP-activated protein kinase (AMPK) is a major mediator of the exercise response and a molecular target to improve insulin sensitivity. To determine if the anaerobic component of the exercise response, which is exaggerated when sprint is performed in severe acute hypoxia, influences sprint exercise-elicited Thr(172)-AMPKα phosphorylation, 10 volunteers performed a single 30-s sprint (Wingate test) in normoxia and in severe acute hypoxia (inspired Po(2): 75 mmHg). Vastus lateralis muscle biopsies were obtained before and immediately after 30 and 120 min postsprint. Mean power output and O(2) consumption were 6% and 37%, respectively, lower in hypoxia than in normoxia. O(2) deficit and muscle lactate accumulation were greater in hypoxia than in normoxia. Carbonylated skeletal muscle and plasma proteins were increased after the sprint in hypoxia. Thr(172)-AMPKα phosphorylation was increased by 3.1-fold 30 min after the sprint in normoxia. This effect was prevented by hypoxia. The NAD(+)-to-NADH.H(+) ratio was reduced (by 24-fold) after the sprints, with a greater reduction in hypoxia than in normoxia (P exercise in human skeletal muscle is altered in severe acute hypoxia, which abrogated Thr(172)-AMPKα phosphorylation, likely due to lower LKB1 activation by SIRT1.

  10. Division I Hockey Players Generate More Power Than Division III Players During on- and Off-Ice Performance Tests.

    Science.gov (United States)

    Peterson, Ben J; Fitzgerald, John S; Dietz, Calvin C; Ziegler, Kevin S; Ingraham, Stacy J; Baker, Sarah E; Snyder, Eric M

    2015-05-01

    Current research has found anthropometric and physiological characteristics of hockey players that are correlated to performance. These characteristics, however, have never been examined to see whether significant differences exist between on- and off-ice performance markers at different levels of play; Division I, Elite Junior, and Division III. The purpose of this study was to examine the differences that may exist between these characteristics in Division I (24), Elite Junior (10), and Division III hockey (11) players. Forty-five (age: 18-24 years) hockey players completed anthropometric, on-ice, and off-ice tests to ascertain average measures for each division of play. On-ice testing was conducted in full hockey gear and consisted of acceleration, top-speed, and on-ice repeated shift test (RST). Off-ice tests included vertical jump, Wingate, grip strength, and a graded exercise test performed on a skating treadmill to ascertain their (Equation is included in full-text article.). Division I players had significantly lower body fat than their Division III peers (p = 0.004). Division I players also scored significantly better on measures of anaerobic power; vertical jump (p = 0.001), Wingate peak power (p = 0.05), grip strength (p = 0.008), top speed (p = 0.001), and fastest RST course time (p = 0.001) than their Division III counterparts. There was no significant difference between Division I and Elite Junior players for any on- or off-ice performance variable. The results of this study indicate that performance differences between Division I and Division III hockey players seem to be primarily because of the rate of force production.

  11. Validity and Reliability of Skill-Related Fitness Tests for Wheelchair-Using Youth With Spina Bifida.

    Science.gov (United States)

    Bloemen, Manon A; Takken, Tim; Backx, Frank J; Vos, Marleen; Kruitwagen, Cas L; de Groot, Janke F

    2017-06-01

    To determine content validity of the Muscle Power Sprint Test (MPST), and construct validity and reliability of the MPST, 10×5 Meter Sprint Test (10×5MST), slalom test, and One Stroke Push Test (1SPT) in wheelchair-using youth with spina bifida (SB). Clinimetric study. Rehabilitation centers, SB outpatient services, and private practices. A convenience sample of children and adolescents (N=53; 32 boys, 21 girls; age range, 5-19y) with SB who use a manual wheelchair. Participants were recruited through rehabilitation centers, SB outpatient services, pediatric physical therapists, and the BOSK (Association of Physically Disabled Persons and their Parents). Not applicable. Construct validity of the MPST was determined by comparing results with the arm-cranking Wingate Anaerobic Test (WAnT) using paired t tests and Pearson correlation coefficients, while content validity was assessed using time-based criteria for anaerobic testing. Construct validity of the 10×5MST, slalom test, and 1SPT was analyzed by hypothesis testing using Pearson correlation coefficients and multiple regression. For reliability, intraclass correlation coefficients (ICCs) and smallest detectable changes (SDCs) were calculated. For the MPST, the mean ± SD exercise time of 4 sprints was 28.1±6.6 seconds. Correlations between the MPST and arm-cranking WAnT were high (r>.72, P.95), but the SDCs varied widely. The MPST is a valid and reliable test in wheelchair-using youth with SB for measuring anaerobic performance. The 10×5MST and slalom test are valid and reliable for measuring agility. For the 1SPT, both validity and reliability are questionable. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  12. Medical professionals convicted of accessing child pornography--presumptive lifetime prohibition on paediatric practice? Health Care Complaints Commission v Wingate.

    Science.gov (United States)

    Shats, Kathy; Faunce, Thomas

    2008-05-01

    Health Care Complaints Commission v Wingate [2007] NSWCA 326 concerns an appeal from the New South Wales Medical Tribunal regarding its findings on professional misconduct outside the practice of medicine in relation to a doctor convicted of possessing child pornography. The latest in a number of cases on this issue in Australia, it highlights the complexity of such decisions before medical tribunals and boards, as well as the diversity of approaches taken. Considering both this case and the recent Medical Practitioners Board of Victoria case of Re Stephanopoulos [2006] MPBV 12, this column argues that Australian tribunals and medical boards may not yet have achieved the right balance here in terms of protecting public safety and the reputation of the profession as a whole. It makes the case for a position statement from Australian professional bodies to create a presumption of a lifetime prohibition on paediatric practice after a medical professional has been convicted of accessing child pornography.

  13. Anaerobic Digestion: Process

    DEFF Research Database (Denmark)

    Angelidaki, Irini; Batstone, Damien J.

    2011-01-01

    Organic waste may degrade anaerobically in nature as well as in engineered systems. The latter is called anaerobic digestion or biogasification. Anaerobic digestion produces two main outputs: An energy-rich gas called biogas and an effluent. The effluent, which may be a solid as well as liquid...... with very little dry matter may also be called a digest. The digest should not be termed compost unless it specifically has been composted in an aerated step. This chapter describes the basic processes of anaerobic digestion. Chapter 9.5 describes the anaerobic treatment technologies, and Chapter 9.......6 addresses the mass balances and environmental aspects of anaerobic digestion....

  14. Scale effect of anaerobic digestion tests in fed-batch and semi-continuous mode for the technical and economic feasibility of a full scale digester.

    Science.gov (United States)

    Ruffino, Barbara; Fiore, Silvia; Roati, Chiara; Campo, Giuseppe; Novarino, Daniel; Zanetti, Mariachiara

    2015-04-01

    Methane production capacity in mesophilic conditions of waste from two food industry plants was assessed in a semi-pilot (6L, fed-batch) and pilot (300 L, semi-continuous) scale. This was carried out in order to evaluate the convenience of producing heat and electricity in a full scale anaerobic digester. The pilot test was performed in order to obtain more reliable results for the design of the digester. Methane yield, returned from the pilot scale test, was approximately 80% of that from the smaller scale test. This outcome was in line with those from other studies performed in different scales and modes and indicates the success of the pilot scale test. The net electricity produced from the digester accounted for 30-50% of the food industry plants' consumption. The available thermal energy could cover from 10% to 100% of the plant requirements, depending on the energy demand of the processes performed. Copyright © 2015 Elsevier Ltd. All rights reserved.

  15. The effect of four-week high-intensity interval training with beta-alanine supplementation on aerobic and anaerobic performance and some blood parameters in girls basketball players

    Directory of Open Access Journals (Sweden)

    bahareh ketabdar

    2017-06-01

    Full Text Available Background & Objective: The aim of the present study was to determine the effect of four-week high-intensity interval training with beta-alanine supplementation on aerobic and anaerobic performance and some blood parameters in girls basketball players. Materials & Methods: This was a quasi-experimental study. Twenty female basketball players, with the mean age of 24.65 ± 4.81 years, height of 166.97 ± 4.12 cm, weight of 59.15 ± 5.23 kg and body mass index of 21.5 ± 1.23 kg/m2, were divided into two groups, including intervention (exercise + supplement and control groups. Two days before and after the intervention, the subjects performed Wingate test (to estimate the average aerobic power and Bruce test (to estimate VO2max.The subjects attended basketball training two sessions per week; Intervention group performed high-intensity interval training in addition to the basketball training in every session. The dose of beta-alanine supplementation was 2.4, 3.6, 4.8 g per day. After four weeks, creatine kinase and lactate levels and performance tests were reevaluated. Data were analyzed by SPSS software version 21, with a significance level of P0.05. Conclusion: This study showed that high-intensity interval training with beta-alanine supplementation resulted in delay in the fatigue threshold, stabilization of PH and hydrogen ions balance, increased aerobic-anaerobic capacity and exercise performance in female basketball players.

  16. Reliability for running tests for measuring agility and anaerobic muscle power in children and adolescents with cerebral palsy.

    Science.gov (United States)

    Verschuren, Olaf; Takken, Tim; Ketelaar, Marjolijn; Gorter, Jan Willem; Helders, Paul J M

    2007-01-01

    We investigated reliability, construct validity, and feasibility of two sprint tests for children with cerebral palsy (CP). Twenty-six children with CP participated (7-18 years of age; Gross Motor Function Classification System [GMFCS] level I or II). On different occasions, the 10 x 5-Meter Sprint Test and the Muscle Power Sprint Test were scored by different assessors. Excellent interobserver reliability (intraclass correlation [ICC] = 1.0 and ICC >or= 0.97) and test-retest reliability (ICC = 0.97 and ICC >or= 0.97) were obtained. Scores differed significantly on both sprint tests for children classified at GMFCS level I and level II. Mean scores for feasibility ranged from 8.8 to 9.2 on a 10-cm visual analog scale (10 = the best). Both exercise tests are reliable and have good feasibility for children and adolescents with CP (GMFCS level I or II). Construct validity is supported for both sprint tests in children classified at GMFCS level I and level II.

  17. Fastidious anaerobe agar compared with Wilkins-Chalgren agar, brain heart infusion agar, and brucella agar for susceptibility testing of Fusobacterium species.

    OpenAIRE

    Brazier, J S; Goldstein, E J; Citron, D M; Ostovari, M I

    1990-01-01

    Fastidious anaerobe agar supported the growth of 82 strains of fusobacteria better than brain heart infusion agar, brucella agar, and Wilkins-Chalgren agar. Fastidious anaerobe agar showed less hazing and fewer tailing endpoints with beta-lactam antibiotics. Whole-blood supplementation improved the performance of all media. Wilkins-Chalgren agar without blood failed to support the growth of 17% of the strains. All Fusobacterium ulcerans strains were resistant to clindamycin.

  18. The effect of air pollution on diurnal variation of performance in anaerobic tests, cardiovascular and hematological parameters, and blood gases on soccer players following the Yo-Yo Intermittent Recovery Test Level-1.

    Science.gov (United States)

    Boussetta, Nesrin; Abedelmalek, Salma; Aloui, Khouloud; Souissi, Nizar

    2017-01-01

    This study aimed to investigate the effect of air pollution on diurnal variation of performance in anaerobic tests, cardiovascular and hematological parameters, and blood gases on soccer players following the Yo-Yo Intermittent Recovery Test Level-1 (YYIRT1). In a randomized order, 11 healthy soccer players (mean age: 21.8 [range: 20-24] years; height: 178.00 [range: 1.64-1.83] cm; body mass index [BMI]: 23.57 [range: 20.45-28.03] kg.m-2) performed a YYIRT1 at two different times of day (TOD) (08:00 h and 18:00 h) in two areas (i.e. polluted (PA) and non-polluted (NPA)) with a recovery period of ≥ 72 h in between, to determine the maximal oxygen uptake (VO2max). In each test session: resting oral temperature is measured, anaerobic performances (pre- and post-YYIRT1) were performed, cardiovascular parameters and blood samples were collected at: rest, 3 min and 60 min after the YYIRT1, to assess blood gases and hematological parameters. Our results showed that, agility performance, VO2max, red blood cells (RBC), hemoglobin (Hb), pH, and bicarbonate levels (HCO3-) decrease significantly (p effect was slightly accentuated at 18:00 h for some parameters (i.e. Agility, HCO3-, HR, PvCO2, RBC, SBP). However, performances of sprint and Sargent jump test (SJT), oral temperature, rate of perceived exertion scales (RPE), partial pressure of O2 (PvO2), diastolic blood pressure (DBP), and monocytes (MON) were not affected by pollution (p > 0.05). In conclusion, pollution seems to be critical for health stability and performance in response to YYIRT1 especially in the evening and the winter season. Therefore, coaches and athletes should draw attention to the potential importance of land use planning in their training sessions and competitions in the morning in polluted area to minimize the risk of pollution exposure.

  19. Epidemiology of anaerobic infections.

    Science.gov (United States)

    Hnatko, S I

    1983-01-01

    The clinical importance of the anaerobic organisms, especially the toxicogenic Clostridia and some of the nonsporulating anaerobes, has been recognized for some time. Only within the last 20 years, however, owing to improved methodology, have gram-negative anaerobic bacilli, anaerobic cocci, and streptococci been commonly recognized and encountered in clinical infections. Today, anaerobic organisms are common isolates from infections involving intra-abdominal sites, the female genital tract, soft tissue, and oral areas and from major infections involving the lung, brain, and head and neck. Most of these infections are polymicrobial--involving both anaerobic and facultative or aerobic organisms. In some instances, it is difficult to ascertain what role is played by what organisms. No doubt, synergism is present in many cases. Because anaerobes are prevalent normal flora of the body, almost all anaerobic infections are of endogenous origin. Many of these anaerobes are opportunists; given the appropriate set of conditions, they will penetrate tissue and cause infection. Many have been associated with wound infection subsequent to bowel surgery or trauma, tubo-ovarian abscess, perirectal abscess, subphrenic abscess, postabortal sepsis, appendicitis, and many other infectious conditions. This article reviews the distribution of anaerobes in infected hospitalized patients and their relation to infection over a 5-year period.

  20. Use of CAH-degrading bacteria as test-organisms for evaluating the impact of fine zerovalent iron particles on the anaerobic subsurface environment.

    Science.gov (United States)

    Velimirovic, Milica; Simons, Queenie; Bastiaens, Leen

    2015-09-01

    The release of fine zerovalent iron (ZVI) particles in the environment after being introduced for in-situ treatment of compounds like chlorinated aliphatic hydrocarbons (CAHs) may raise questions toward environmental safety, especially for nanoscale materials. Classical single-species ecotoxicity tests do focus on aerobic conditions and are only relevant for the scenario when ZVI-particles reach surface water. Herein, we present an alternative approach where a CAH-degrading mixed bacterial culture was used as test-organisms relevant for the anaerobic subsurface. The impact of different ZVI particles on the bacterial culture was evaluated mainly by quantifying ATP, a reporter molecule giving a general indication of the microbial activity. These lab-scale batch tests were performed in liquid medium, without protecting and buffering aquifer material, as such representing worst-case scenario. The activity of the bacterial culture was negatively influenced by nanoscale zerovalent iron at doses as low as 0.05 g L(-1). On the other hand, concentrations up to 2 g L(-1) of several different types of microscale zerovalent iron (mZVI) particles stimulated the activity. However, very high doses of 15-30 g L(-1) of mZVI showed an inhibiting effect on the bacterial community. Negative effects of ZVIs were confirmed by H2 accumulation in the batch reactors and the absence of lactate consumption. Observed inhibition also corresponded to a pH increase above 7.5, explicable by ZVI corrosion that was found to be dose-dependent. The obtained results suggest that low doses of mZVIs will not show severe inhibition effects on the microbial community once used for in-situ treatment of CAHs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Accelerated anaerobic hydrolysis rates under a combination of intermittent aeration and anaerobic conditions.

    Science.gov (United States)

    Jensen, T R; Lastra Milone, T; Petersen, G; Andersen, H R

    2017-04-01

    Anaerobic hydrolysis in activated return sludge was investigated in laboratory scale experiments to find if intermittent aeration would accelerate anaerobic hydrolysis rates compared to anaerobic hydrolysis rates under strict anaerobic conditions. The intermittent reactors were set up in a 240 h experiment with intermittent aeration (3 h:3 h) in a period of 24 h followed by a subsequent anaerobic period of 24 h in a cycle of 48 h which was repeated five times during the experiment. The anaerobic reactors were kept under strict anaerobic conditions in the same period (240 h). Two methods for calculating hydrolysis rates based on soluble chemical oxygen demand were compared. Two-way analysis of variance with the Bonferroni post-test was performed in order to register any significant difference between reactors with intermittent aeration and strictly anaerobic conditions respectively. The experiment demonstrated a statistically significant difference in favor of the reactors with intermittent aeration showing a tendency towards accelerated anaerobic hydrolysis rates due to application of intermittent aeration. The conclusion of the work is thus that intermittent aeration applied in the activated return sludge process can improve the treatment capacity further in full scale applications.

  2. First comprehensive evaluation of the M.I.C. evaluator device compared to Etest and CLSI reference dilution methods for antimicrobial susceptibility testing of clinical strains of anaerobes and other fastidious bacterial species.

    Science.gov (United States)

    Rennie, R P; Turnbull, L; Brosnikoff, C; Cloke, J

    2012-04-01

    The new M.I.C. Evaluator strip uses test methodology and the recording of results that are similar to those of Etest. For this first assessment, 102 clinical strains of anaerobic bacteria from 12 genera and 155 strains from 7 genera and 8 species of fastidious bacteria were tested by M.I.C. Evaluator, Etest, and agar dilution or broth microdilution as a reference standard. Ampicillin, amoxicillin, amoxicillin-clavulanate, cefotaxime, ciprofloxacin, erythromycin, imipenem, levofloxacin, metronidazole, penicillin, and tetracycline were tested depending on the species. Agar dilution for anaerobes was performed according to CLSI document M11-A7. For the fastidious bacteria, CLSI document M45-A2 was followed. For the anaerobes, essential and categorical agreement between M.I.C. Evaluator and Etest was >90%. Compared to agar dilution, essential agreement was low for both strip tests, and many very major errors were observed for metronidazole (13 to 14%) and penicillin (8 to 9%) with isolates from the Bacteroides fragilis group and Clostridium species. For fastidious species, essential agreements for M.I.C. Evaluator and Etest plus or minus one doubling dilution were >95%. Compared to broth microdilution, essential agreements were low (40 to 90%) plus or minus one dilution and were >90% plus or minus two dilutions, with high overall category agreement (CA). Major and minor errors were within established parameters for all strains tested. The M.I.C. Evaluator strips were equivalent to Etest for anaerobes and fastidious species. These observations require further investigation to determine which methods provide the most accurate MIC for clinical utility. The further evaluation of additional M.I.C. Evaluator agents will be performed as they become available.

  3. Intraspecific variation in aerobic and anaerobic locomotion

    DEFF Research Database (Denmark)

    Svendsen, Jon Christian; Tirsgård, Bjørn; Cordero, Gerardo A.

    2015-01-01

    Intraspecific variation and trade-off in aerobic and anaerobic traits remain poorly understood in aquatic locomotion. Using gilthead sea bream (Sparus aurata) and Trinidadian guppy (Poecilia reticulata), both axial swimmers, this study tested four hypotheses: (1) gait transition from steady...... to unsteady (i.e., burst-assisted) swimming is associated with anaerobic metabolism evidenced as excess post exercise oxygen consumption (EPOC); (2) variation in swimming performance (critical swimming speed; U crit) correlates with metabolic scope (MS) or anaerobic capacity (i.e., maximum EPOC); (3...

  4. Oxygen Effects in Anaerobic Digestion

    Directory of Open Access Journals (Sweden)

    Deshai Botheju

    2009-10-01

    Full Text Available Interaction of free oxygen in bio-gasification is a sparsely studied area, apart from the common argument of oxygen being toxic and inhibitory for anaerobic micro-cultures. Some studies have, however, revealed increased solubilisation of organic matter in the presence of some free oxygen in anaerobic digestion. This article analyses these counterbalancing phenomena with a mathematical modelling approach using the widely accepted biochemical model ADM 1. Aerobic oxidation of soluble carbon and inhibition of obligatory anaerobic organisms are modelled using standard saturation type kinetics. Biomass dependent first order hydrolysis kinetics is used to relate the increased hydrolysis rate with oxygen induced increase in biomass growth. The amended model, ADM 1-Ox (oxygen, has 25 state variables and 22 biochemical processes, presented in matrix form. The computer aided simulation tool AQUASIM 2.1 is used to simulate the developed model. Simulation predictions are evaluated against experimental data obtained using a laboratory batch test array comprising miniature anaerobic bio-reactors of 100 ml total volume each, operated under different initial air headspaces giving rise to the different oxygen loading conditions. The reactors were initially fed with a glucose solution and incubated at 35 Celsius, for 563 hours. Under the oxygen load conditions of 22, 44 and 88 mg/L, the ADM1-Ox model simulations predicted the experimental methane potentials quite adequately. Both the experimental data and the simulations suggest a linear reduction of methane potential with respect to the increase in oxygen load within this range.

  5. Comparing four non-invasive methods to determine the ventilatory anaerobic threshold during cardiopulmonary exercise testing in children with congenital heart or lung disease.

    Science.gov (United States)

    Visschers, Naomi C A; Hulzebos, Erik H; van Brussel, Marco; Takken, Tim

    2015-11-01

    The ventilatory anaerobic threshold (VAT) is an important method to assess the aerobic fitness in patients with cardiopulmonary disease. Several methods exist to determine the VAT; however, there is no consensus which of these methods is the most accurate. To compare four different non-invasive methods for the determination of the VAT via respiratory gas exchange analysis during a cardiopulmonary exercise test (CPET). A secondary objective is to determine the interobserver reliability of the VAT. CPET data of 30 children diagnosed with either cystic fibrosis (CF; N = 15) or with a surgically corrected dextro-transposition of the great arteries (asoTGA; N = 15) were included. No significant differences were found between conditions or among testers. The RER = 1 method differed the most compared to the other methods, showing significant higher results in all six variables. The PET-O2 method differed significantly on five of six and four of six exercise variables with the V-slope method and the VentEq method, respectively. The V-slope and the VentEq method differed significantly on one of six exercise variables. Ten of thirteen ICCs that were >0.80 had a 95% CI > 0.70. The RER = 1 method and the V-slope method had the highest number of significant ICCs and 95% CIs. The V-slope method, the ventilatory equivalent method and the PET-O2 method are comparable and reliable methods to determine the VAT during CPET in children with CF or asoTGA. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  6. The effects of theaflavin-enriched black tea extract on muscle soreness, oxidative stress, inflammation, and endocrine responses to acute anaerobic interval training: a randomized, double-blind, crossover study

    Directory of Open Access Journals (Sweden)

    Golem Devon L

    2010-02-01

    Full Text Available Abstract Background Muscle soreness and decreased performance often follow a bout of high-intensity exercise. By reducing these effects, an athlete can train more frequently and increase long-term performance. The purpose of this study is to examine whether a high-potency, black tea extract (BTE alters the delayed onset muscle soreness (DOMS, oxidative stress, inflammation, and cortisol (CORT responses to high-intensity anaerobic exercise. Methods College-age males (N = 18 with 1+ yrs of weight training experience completed a double-blind, placebo-controlled, crossover study. Subjects consumed the BTE (1,760 mg BTE·d-1 or placebo (PLA for 9 days. Each subject completed two testing sessions (T1 & T2, which occurred on day 7 of the intervention. T1 & T2 consisted of a 30 s Wingate Test plus eight 10 s intervals. Blood samples were obtained before, 0, 30 & 60 min following the interval sessions and were used to analyze the total to oxidized glutathione ratio (GSH:GSSG, 8-isoprostane (8-iso, CORT, and interleukin 6 (IL-6 secretion. DOMS was recorded at 24 & 48 h post-test using a visual analog scale while BTE or PLA continued to be administered. Significance was set at P . Results Compared to PLA, BTE produced significantly higher average peak power (P = 0.013 and higher average mean power (P = 0.067 across nine WAnT intervals. BTE produced significantly lower DOMS compared to PLA at 24 h post test (P and 48 h post test (P . Compared to PLA, BTE had a slightly higher GSH:GSSG ratio at baseline which became significantly higher at 30 and 60 min post test (P . AUC analysis revealed BTE to elicit significantly lower GSSG secretion (P = 0.009, significantly higher GSH:GSSG ratio (P = 0.001, and lower CORT secretion (P = 0.078 than PLA. AUC analysis did not reveal a significant difference in total IL-6 response (P = 0.145 between conditions. Conclusions Consumption of theaflavin-enriched black tea extract led to improved recovery and a reduction in

  7. Efeitos da suplementação prolongada de creatina mono-hidratada sobre o desempenho anaeróbio de adultos jovens treinados Effects of long-term creatine monohydrate supplementation on anaerobic performance of trained young adults

    Directory of Open Access Journals (Sweden)

    Leandro Ricardo Altimari

    2010-06-01

    Full Text Available O objetivo do presente estudo foi investigar o impacto de oito semanas de suplementação de creatina mono-hidratada (Crm sobre o desempenho anaeróbio de adultos jovens treinados. Vinte e seis estudantes de educação física, do sexo masculino, saudáveis, foram divididos aleatoriamente em grupo creatina (GCr, n = 13; 22,5 ± 2,7 anos; 74,9 ± 6,8kg, 178,5 ± 4,8cm e grupo placebo (GPl, n = 13; 22,9 ± 3,2 anos, 71,9 ± 11,3kg, 178,6 ± 4,0cm. Os indivíduos ingeriram em sistema duplo-cego doses de Crm ou placebo-maltodextrina (20 g.d-1 por 5 dias e 3 g.d-1 por 51 dias subsequentes. Ambos os grupos tiveram seus hábitos alimentares e os níveis de aptidão física controlados anteriormente. O teste anaeróbio de Wingate (TW foi usado para avaliar o desempenho anaeróbio antes e após o período de ingestão de Crm ou placebo. Os índices de desempenho analisados foram: potência pico relativa (PPR, potência média relativa (PMR, trabalho total relativo (TTR e índice de fadiga (IF. Para tratamento estatístico foi utilizado ANOVA, seguido pelo teste de post hoc Tukey, quando PThe objective of the present study was to investigate the impact of eight weeks of creatine monohydrate (Crm supplementation on the anaerobic performance of young trained adults. Twenty-six healthy male physical education students were randomly divided in creatine group (CrG, n = 13; 22.5 ± 2.7 years; 74.9 ± 6.8 kg; 178.5 ± 4.8 cm and placebo group (PlG, n = 13; 22.9 ± 3.2 years; 71.9 ± 11.3 kg; 178.6 ± 4.0 cm. The subjects received in a double-blind system a Crm or placebo-maltodextrin dose (20 g.d-1 for 5 days and 3 g.d-1 for 51 subsequent days. Both groups had their eating habits and levels of physical fitness previously controlled. The Wingate anaerobic test (WT was used to evaluate the anaerobic performance before and after the ingestion period of Crm or placebo. The performance indexes assessed were: relative peak power (RPP, relative mean power (RMP

  8. Effects of Beetroot Juice Supplementation on a 30-s High-Intensity Inertial Cycle Ergometer Test

    Directory of Open Access Journals (Sweden)

    Raul Domínguez

    2017-12-01

    Full Text Available Background: Beetroot juice (BJ is rich in inorganic nitrates and has proved effective at increasing blood nitric oxide (NO levels. When used as a supplement BJ has shown an ergogenic effect on cardiorespiratory resistance exercise modalities, yet few studies have examined its impact on high intensity efforts. Objective: To assess the effects of BJ intake on anaerobic performance in a Wingate test. Methods: Fifteen trained men (age 21.46 ± 1.72 years, height 1.78 ± 0.07 cm and weight 76.90 ± 8.67 kg undertook a 30-s maximum intensity test on an inertial cycle ergometer after drinking 70 mL of BJ (5.6 mmol NO3− or placebo. Results: Despite no impacts of BJ on the mean power recorded during the test, improvements were produced in peak power (6% (p = 0.034, average power 0–15 s (6.7% (p = 0.048 and final blood lactate levels (82.6% (p < 0.001, and there was a trend towards a shorter time taken to attain peak power (−8.4% (p = 0.055. Conclusions: Supplementation with BJ has an ergonomic effect on maximum power output and on average power during the first 15 s of a 30-s maximum intensity inertial cycle ergometer test.

  9. Comparing four non-invasive methods to determine the ventilatory anaerobic threshold during cardiopulmonary exercise testing in children with congenital heart or lung disease

    NARCIS (Netherlands)

    Visschers, Naomi C A; Hulzebos, Erik H.|info:eu-repo/dai/nl/304818224; van Brussel, Marco|info:eu-repo/dai/nl/30481962X; Takken, Tim|info:eu-repo/dai/nl/184586674

    2015-01-01

    Background: The ventilatory anaerobic threshold (VAT) is an important method to assess the aerobic fitness in patients with cardiopulmonary disease. Several methods exist to determine the VAT; however, there is no consensus which of these methods is the most accurate. Objective: To compare four

  10. Long-chain fatty acids inhibition and adaptation process in anaerobic thermophilic digestion: Batch tests, microbial community structure and mathematical modelling

    DEFF Research Database (Denmark)

    Paltsi, Jordi; Illa, J.; Prenafeta-Boldu, F.X.

    2010-01-01

    Biomass samples taken during the continuous operation of thermophilic anaerobic digestors fed with manure and exposed to successive inhibitory pulses of long-chain fatty acids (LCFA) were characterized in terms of specific metabolic activities and 16S rDNA DGGE profiling of the microbial communit...

  11. Anaerobic Digestion and its Applications

    Science.gov (United States)

    Anaerobic digestion is a natural biological process. The initials "AD" may refer to the process of anaerobic digestion, or the built systems of anaerobic digesters. While there are many kinds of digesters, the biology is basically the same for all. Anaerobic digesters are built...

  12. Investigation on by-products of bioenergy systems (anaerobic digestion and gasification) as potential crop nutrient using FTIR, XRD, SEM analysis and phyto-toxicity test.

    Science.gov (United States)

    Kataki, Sampriti; Hazarika, Samarendra; Baruah, D C

    2017-07-01

    Success and acceptability of the bio energy conversion technology to a large extent depend upon management of the inevitable by-products generated during the conversion process. By-products can be considered favourable as organic fertilizer as they retain nutrients with varying composition depending upon input biomass. However, characteristics of these heterogeneous resources with respect to feedstock and processing conditions have to be assessed to state on their agricultural and environmental benefits. Therefore, 3 types of anaerobic digestion by-products (digestate) from surplus biomass viz. cow dung, Ipomoea carnea:cow dung (60:40 dry weight basis) and rice straw:green gram stover:cow dung (30:30:40 dry weight basis) and one gasification by-product (biochar) from rice husk are considered to understand the fertilizer prospects. Considering 3 potential application options, digestate from each feedstock option was further processed as separated solid, separated liquid and ash from solid digestates. Thus, a total of 10 by-products were investigated for understanding their prospects as fertilizer using Fourier Transform Infrared Spectroscopy (FTIR), X-ray diffraction (XRD), Scanning Electron Microscopy (SEM) and Energy Dispersive X ray Spectroscopy (EDX) and phyto-toxicity test to have a broad insight in terms of their organic, mineral, elemental composition, morphological feature and potential phyto-toxicity. In general, irrespective of origin of feedstock, solid digestate, ash digestate and char showed similarity in terms of composition of functional groups with some degree of variation in relative content as reflected by FTIR analysis. Dominance of organic functional groups in separated solid digestates compared to liquid fraction indicated the former as favourable organic amendments. Quartz was the prevalent mineral phase in all separated solid, ash digestate and rice husk char. Digestates in ash phase represent more concentrated plant nutrient source with

  13. Anaerobes in bacterial vaginosis

    Directory of Open Access Journals (Sweden)

    Aggarwal A

    2003-01-01

    Full Text Available Four hundred high vaginal swabs were taken from patients attending gynaecology and obstetrics department of Govt. medical college, Amritsar. The patients were divided into four groups i.e. women in pregnancy (Group I, in labour/post partum (Group II, with abnormal vaginal discharge or bacterial vaginosis (Group III and asymptomatic women as control (Group IV. Anaerobic culture of vaginal swabs revealed that out of 400 cases, 212(53% were culture positive. Maximum isolation of anaerobes was in group III (84% followed by group II (56%, group I (36% and control group (15%. Gram positive anaerobes (69.2% out numbered gram negatives (30.8%. Among various isolates Peptostreptococcus spp. and Bacteroides spp. were predominant.

  14. Anaerobic Threshold and Salivary α-amylase during Incremental Exercise.

    Science.gov (United States)

    Akizuki, Kazunori; Yazaki, Syouichirou; Echizenya, Yuki; Ohashi, Yukari

    2014-07-01

    [Purpose] The purpose of this study was to clarify the validity of salivary α-amylase as a method of quickly estimating anaerobic threshold and to establish the relationship between salivary α-amylase and double-product breakpoint in order to create a way to adjust exercise intensity to a safe and effective range. [Subjects and Methods] Eleven healthy young adults performed an incremental exercise test using a cycle ergometer. During the incremental exercise test, oxygen consumption, carbon dioxide production, and ventilatory equivalent were measured using a breath-by-breath gas analyzer. Systolic blood pressure and heart rate were measured to calculate the double product, from which double-product breakpoint was determined. Salivary α-amylase was measured to calculate the salivary threshold. [Results] One-way ANOVA revealed no significant differences among workloads at the anaerobic threshold, double-product breakpoint, and salivary threshold. Significant correlations were found between anaerobic threshold and salivary threshold and between anaerobic threshold and double-product breakpoint. [Conclusion] As a method for estimating anaerobic threshold, salivary threshold was as good as or better than determination of double-product breakpoint because the correlation between anaerobic threshold and salivary threshold was higher than the correlation between anaerobic threshold and double-product breakpoint. Therefore, salivary threshold is a useful index of anaerobic threshold during an incremental workload.

  15. Anaerobic work capacity in elite wheelchair athletes

    NARCIS (Netherlands)

    van der Woude, L H; Bakker, W H; Elkhuizen, J W; Veeger, DirkJan (H. E. J.); Gwinn, T

    1997-01-01

    To study the anaerobic work capacity in wheelchair athletes, 67 elite wheelchair athletes (50 male) were studied in a 30-second sprint test on a computer-controlled wheelchair ergometer during the World Championships and Games for the Disabled in Assen (1990). The experimental set-up (ergometer,

  16. The anaerobic digestion process

    Energy Technology Data Exchange (ETDEWEB)

    Rivard, C.J. [National Renewable Energy Lab., Golden, CO (United States); Boone, D.R. [Oregon Graduate Inst., Portland, OR (United States)

    1996-01-01

    The microbial process of converting organic matter into methane and carbon dioxide is so complex that anaerobic digesters have long been treated as {open_quotes}black boxes.{close_quotes} Research into this process during the past few decades has gradually unraveled this complexity, but many questions remain. The major biochemical reactions for forming methane by methanogens are largely understood, and evolutionary studies indicate that these microbes are as different from bacteria as they are from plants and animals. In anaerobic digesters, methanogens are at the terminus of a metabolic web, in which the reactions of myriads of other microbes produce a very limited range of compounds - mainly acetate, hydrogen, and formate - on which the methanogens grow and from which they form methane. {open_quotes}Interspecies hydrogen-transfer{close_quotes} and {open_quotes}interspecies formate-transfer{close_quotes} are major mechanisms by which methanogens obtain their substrates and by which volatile fatty acids are degraded. Present understanding of these reactions and other complex interactions among the bacteria involved in anaerobic digestion is only now to the point where anaerobic digesters need no longer be treated as black boxes.

  17. Anaerobic digestion without biogas?

    NARCIS (Netherlands)

    Kleerebezem, R.; Joosse, B.; Rozendaal, R.; Van Loosdrecht, M.C.M.

    2015-01-01

    Anaerobic digestion for the production of methane containing biogas is the classic example of a resource recovery process that combines stabilization of particulate organic matter or wastewater treatment with the production of a valuable end-product. Attractive features of the process include the

  18. Antimicrobial Susceptibility of Enteric Gram Negative Facultative Anaerobe Bacilli in Aerobic versus Anaerobic Conditions.

    Directory of Open Access Journals (Sweden)

    Zachary DeMars

    Full Text Available Antimicrobial treatments result in the host's enteric bacteria being exposed to the antimicrobials. Pharmacodynamic models can describe how this exposure affects the enteric bacteria and their antimicrobial resistance. The models utilize measurements of bacterial antimicrobial susceptibility traditionally obtained in vitro in aerobic conditions. However, in vivo enteric bacteria are exposed to antimicrobials in anaerobic conditions of the lower intestine. Some of enteric bacteria of food animals are potential foodborne pathogens, e.g., Gram-negative bacilli Escherichia coli and Salmonella enterica. These are facultative anaerobes; their physiology and growth rates change in anaerobic conditions. We hypothesized that their antimicrobial susceptibility also changes, and evaluated differences in the susceptibility in aerobic vs. anaerobic conditions of generic E. coli and Salmonella enterica of diverse serovars isolated from cattle feces. Susceptibility of an isolate was evaluated as its minimum inhibitory concentration (MIC measured by E-Test® following 24 hours of adaptation to the conditions on Mueller-Hinton agar, and on a more complex tryptic soy agar with 5% sheep blood (BAP media. We considered all major antimicrobial drug classes used in the U.S. to treat cattle: β-lactams (specifically, ampicillin and ceftriaxone E-Test®, aminoglycosides (gentamicin and kanamycin, fluoroquinolones (enrofloxacin, classical macrolides (erythromycin, azalides (azithromycin, sulfanomides (sulfamethoxazole/trimethoprim, and tetracyclines (tetracycline. Statistical analyses were conducted for the isolates (n≥30 interpreted as susceptible to the antimicrobials based on the clinical breakpoint interpretation for human infection. Bacterial susceptibility to every antimicrobial tested was statistically significantly different in anaerobic vs. aerobic conditions on both media, except for no difference in susceptibility to ceftriaxone on BAP agar. A satellite

  19. Antimicrobial Susceptibility of Enteric Gram Negative Facultative Anaerobe Bacilli in Aerobic versus Anaerobic Conditions.

    Science.gov (United States)

    DeMars, Zachary; Biswas, Silpak; Amachawadi, Raghavendra G; Renter, David G; Volkova, Victoriya V

    2016-01-01

    Antimicrobial treatments result in the host's enteric bacteria being exposed to the antimicrobials. Pharmacodynamic models can describe how this exposure affects the enteric bacteria and their antimicrobial resistance. The models utilize measurements of bacterial antimicrobial susceptibility traditionally obtained in vitro in aerobic conditions. However, in vivo enteric bacteria are exposed to antimicrobials in anaerobic conditions of the lower intestine. Some of enteric bacteria of food animals are potential foodborne pathogens, e.g., Gram-negative bacilli Escherichia coli and Salmonella enterica. These are facultative anaerobes; their physiology and growth rates change in anaerobic conditions. We hypothesized that their antimicrobial susceptibility also changes, and evaluated differences in the susceptibility in aerobic vs. anaerobic conditions of generic E. coli and Salmonella enterica of diverse serovars isolated from cattle feces. Susceptibility of an isolate was evaluated as its minimum inhibitory concentration (MIC) measured by E-Test® following 24 hours of adaptation to the conditions on Mueller-Hinton agar, and on a more complex tryptic soy agar with 5% sheep blood (BAP) media. We considered all major antimicrobial drug classes used in the U.S. to treat cattle: β-lactams (specifically, ampicillin and ceftriaxone E-Test®), aminoglycosides (gentamicin and kanamycin), fluoroquinolones (enrofloxacin), classical macrolides (erythromycin), azalides (azithromycin), sulfanomides (sulfamethoxazole/trimethoprim), and tetracyclines (tetracycline). Statistical analyses were conducted for the isolates (n≥30) interpreted as susceptible to the antimicrobials based on the clinical breakpoint interpretation for human infection. Bacterial susceptibility to every antimicrobial tested was statistically significantly different in anaerobic vs. aerobic conditions on both media, except for no difference in susceptibility to ceftriaxone on BAP agar. A satellite experiment

  20. Anaerobic SBR treatment of coal conversion wastewaters: Eighth quarterly report

    Energy Technology Data Exchange (ETDEWEB)

    Ketchum, L.H. Jr.

    1987-12-11

    Results are presented for anaerobic biodegradation of constituents of coal conversion wastewater. Biochemical Methane Potential tests were employed. The relative toxicity of each constituent on anaerobic phenol degradation was also tested. Methylated phenols tended to be more inhibitory to phenol degradation than other hydroxylated and nitrogen containing aromatics. Studies of reaction intermediates of degradation are underway. Several intermediates have been identified in the degradation of p-cresol. 1 fig., 2 tabs. (CBS)

  1. New perspectives in anaerobic digestion

    DEFF Research Database (Denmark)

    van Lier, J.B.; Tilche, A.; Ahring, Birgitte Kiær

    2001-01-01

    The IWA specialised group on anaerobic digestion (AD) is one of the oldest working groups of the former IAWQ organisation. Despite the fact that anaerobic technology dates back more than 100 years, the technology is still under development, adapting novel treatment systems to the modern...... requirements. In fact, most advances were achieved during the last three decades, when high-rate reactor systems were developed and a profound insight was obtained in the microbiology of the anaerobic communities. This insight led to a better understanding of anaerobic treatment and, subsequently, to a broader...

  2. Accelerated anaerobic hydrolysis rates under a combination of intermittent aeration and anaerobic conditions

    DEFF Research Database (Denmark)

    Jensen, T. R.; Lastra Milone, T.; Petersen, G.

    2017-01-01

    for calculating hydrolysis rates based on soluble COD were compared. Two-way ANOVA with the Bonferroni post-test was performed in order to register any significant difference between reactors with intermittent aeration and strictly anaerobic conditions respectively. The experiment demonstrated a statistically...

  3. Heavy metal influence from anaerobic digestion. Tungmetalpaavirkning af anaerob udraadning

    Energy Technology Data Exchange (ETDEWEB)

    Westermann, P. (Afd. for Generel Mikrobiologi, Koebenhavns Universitet (DK)); Ahring, B. (Institut for Bioteknologi, DTH (DK))

    1990-01-01

    The increased use of anaerobic digestion in farming and industry, and in connection with sewage sludge, has created the need for an understanding of the biological processes in the process tanks/biomass conversion plants. It is important to understand the weaknesses of the physical and chemical processes. The article deals with the influence of heavy metals from anaerobic digestion. (CLS).

  4. Anaerobic wastewater treatment using anaerobic baffled bioreactor: a review

    Science.gov (United States)

    Hassan, Siti; Dahlan, Irvan

    2013-09-01

    Anaerobic wastewater treatment is receiving renewed interest because it offers a means to treat wastewater with lower energy investment. Because the microorganisms involved grow more slowly, such systems require clever design so that the microbes have sufficient time with the substrate to complete treatment without requiring enormous reactor volumes. The anaerobic baffled reactor has inherent advantages over single compartment reactors due to its circulation pattern that approaches a plug flow reactor. The physical configuration of the anaerobic baffled reactor enables significant modifications to be made; resulting in a reactor which is proficient of treating complex wastewaters which presently require only one unit, ultimately significant reducing capital costs. This paper also concerns about mechanism, kinetic and hydrodynamic studies of anaerobic digestion for future application of the anaerobic baffled reactor for wastewater treatment.

  5. Prevailing Torque Locking Feature in Threaded Fasteners Using Anaerobic Adhesive

    Science.gov (United States)

    Hernandez, Alan; Hess, Daniel P.

    2016-01-01

    This paper presents results from tests to assess the use of anaerobic adhesive for providing a prevailing torque locking feature in threaded fasteners. Test procedures are developed and tests are performed on three fastener materials, four anaerobic adhesives, and both unseated assembly conditions. Five to ten samples are tested for each combination. Tests for initial use, reuse without additional adhesive, and reuse with additional adhesive are performed for all samples. A 48-hour cure time was used for all initial use and reuse tests. Test data are presented as removal torque versus removal angle with the specification required prevailing torque range added for performance assessment. Percent specification pass rates for the all combinations of fastener material, adhesive, and assembly condition are tabulated and reveal use of anaerobic adhesive as a prevailing torque locking feature is viable. Although not every possible fastener material and anaerobic adhesive combination provides prevailing torque values within specification, any combination can be assessed using the test procedures presented. Reuse without additional anaerobic adhesive generally provides some prevailing torque, and in some cases within specification. Reuse with additional adhesive often provides comparable removal torque data as in initial use.

  6. Limiar anaeróbico (V4 e frequência cardíaca de cavalos Crioulos condicionados para prova funcional Anaerobic threshold (V4 and heart rate of Crioulo horses conditioned for functional testing

    Directory of Open Access Journals (Sweden)

    L.A. Amaral

    2013-02-01

    Full Text Available Determinou-se o limiar anaeróbico (V4 de 23 cavalos Crioulos hígidos em treinamento. Os animais selecionados foram submetidos a testes de desempenho, composto por três etapas de velocidade progressiva de 6m/s, 8m/s e 10m/s, com duração de cinco minutos cada etapa, até que fosse atingida a concentração de 4mmol/dL de lactato sanguíneo. As concentrações de lactato sanguíneo elevaram-se a partir da velocidade de exercício de 6,0m/s, sendo que 20 animais (90% atingiram 4mmol/L de lactato na velocidade entre 6 - 8m/s, com média de frequência cardíaca que variou de 121 a 140bpm. Concluiu-se que a V4 do cavalo Crioulo está entre as velocidades de 6 - 8m/s e a frequência cardíaca entre 121 - 140bpm.The anaerobic threshold (V4 while running on a track is used in many breeds to evaluate physical conditioning and to establish a training regimen, but these data have not been obtained for the Crioulo breed. This study evaluated 23 healthy Crioulo horses to determine the anaerobic threshold (V4 during training. The selected animals were subjected to a performance test on a track. The test consisted of three five minute stages with increasing speeds of 6m/s, 8 m/s and 10m/s until the blood lactate concentration reached 4mmol/dL. Blood lactate concentrations began to increase at the exercise speed of 6m/s, and 90% (n=20 of the animals reached 4mmol/dL lactate between 6-8m/s, with an average heart rate ranging from 121 to 140bpm at these speeds. Our results demonstrate that the V4 of the Crioulo horse is between 6-8m/s at a heart rate between 121 and 140bpm.

  7. Anaerobic digestion of piggery waste

    NARCIS (Netherlands)

    Velsen, van A.F.M.

    1981-01-01

    Anaerobic digestion is a biological process by which organic matter is converted to methane and carbon dioxide by microbes in the absence of air (oxygen). In nature, anaerobic conversions occur at all places where organic material accumulates and the supply of oxygen is deficient, e.g. in marshes

  8. Economic viability of anaerobic digestion

    Energy Technology Data Exchange (ETDEWEB)

    Wellinger, A. [INFOENERGIE, Ettenhausen (Switzerland)

    1996-01-01

    The industrial application of anaerobic digestion is a relatively new, yet proven waste treatment technology. Anaerobic digestion reduces and upgrades organic waste, and is a good way to control air pollution as it reduces methane and nitrous gas emissions. For environmental and energy considerations, anaerobic digestion is a nearly perfect waste treatment process. However, its economic viability is still in question. A number of parameters - type of waste (solid or liquid), digester system, facility size, product quality and end use, environmental requirements, cost of alternative treatments (including labor), and interest rates - define the investment and operating costs of an anaerobic digestion facility. Therefore, identical facilities that treat the same amount and type of waste may, depending on location, legislation, and end product characteristics, reveal radically different costs. A good approach for evaluating the economics of anaerobic digestion is to compare it to treatment techniques such as aeration or conventional sewage treatment (for industrial wastewater), or composting and incineration (for solid organic waste). For example, the cost (per ton of waste) of in-vessel composting with biofilters is somewhat higher than that of anaerobic digestion, but the investment costs 1 1/2 to 2 times more than either composting or anaerobic digestion. Two distinct advantages of anaerobic digestion are: (1) it requires less land than either composting or incinerating, which translates into lower costs and milder environmental and community impacts (especially in densely populated areas); and (2) it produces net energy, which can be used to operate the facility or sold to nearby industries.

  9. New perspectives in anaerobic digestion.

    NARCIS (Netherlands)

    Lier, van J.B.; Tilche, A.; Ahring, B.K.; Macarie, H.; Moletta, R.; Dohanyos, M.; Hulshoff Pol, L.W.; Lens, P.N.L.; Verstraete, W.

    2001-01-01

    The IWA specialised group on anaerobic digestion (AD) is one of the oldest working groups of the former IAWQ organisation. Despite the fact that anaerobic technology dates back more than 100 years, the technology is still under development, adapting novel treatment systems to the modern

  10. Anaerobic thermophilic biogas process

    Energy Technology Data Exchange (ETDEWEB)

    Angelidaki, I.

    1992-06-01

    Investigations into several important aspects concerning thermophilic, anaerobic treatment of livestock wastes and other types of wastes in Denmark was carried out. Lipids, typically found in industrial organic waste, could be effectively degraded during anaerobic treatment with a high biogas yield. Long-chain fatty acids (LCFA) could also inhibit the biogas process at relatively low concentrations. Lipid-containing waste should be introduced gradually and fed continuously to the biogas process in order to permit adaptation. Fed-bacth cultivation was shown to be a successful method for enriching bacteria which are exposed to substrate inhibition. The end product of the degradation were methane and carbon dioxide. Ammonia concentrations at or above 4 g-N/l were shown to inhibit thermophilic digestion of cattle manure, but if the ammonia concentration was gradually increased, adaptation of the process occurred. It was found that addition of bentonite or the waste product bentonite-bound oil counteracted to some extent the inhibitory effect of ammonia. The effect was observed only when the ammonia concentration was increased gradually. When the ammonia load was high, reduction of the temperature below 55 Deg. C was shown to have a positive effect on process performance, while at ammonia non-inhibitory concentrations a temperature of 55 deg. C was found to be the optimal temperature. A mathematical model of the biogas process was formulated with main emphasis on free ammonia inhibition, pH simulation and temperature effects. (au) (140 refs.).

  11. Potential of hydrolysis of particulate COD in extended anaerobic conditions to enhance biological phosphorous removal.

    Science.gov (United States)

    Jabari, P; Yuan, Q; Oleszkiewicz, J A

    2016-11-01

    The effect of anaerobic hydrolysis of particulate COD (pCOD) on biological phosphorous removal in extended anaerobic condition was investigated through (i) sequencing batch reactors (SBR)s with anaerobic hydraulic retention time (HRT) of 0.8, 2, and 4 h; (ii) batch tests using biomass from a full scale biological nutrient removal (BNR) plant; and (iii) activated sludge modeling (BioWin 4.1 simulation). The results from long-term SBRs operation showed that phosphorus removal was correlated to the ratio of filtered COD (FCOD) to total phosphorus (TP) in the influent. Under conditions with low FCOD/TP ratio (average of 20) in the influent, extending anaerobic HRT to 4 h in the presence of pCOD did not significantly improve overall phosphorous removal. During the period with high FCOD/TP ratio (average of 37) in the influent, all SBRs removed phosphorous completely, and the long anaerobic HRT did not have negative effect on overall phosphorous removal. The batch tests also showed that pCOD at different concentration during 4 h test did not affect the rate of anaerobic phosphorus release. The rate of anaerobic hydrolysis of pCOD was significantly low and extending the anaerobic HRT was ineffective. The simulation (BioWin 4.1) of SBRs with low influent FCOD/TP ratio showed that the default kinetics of anaerobic hydrolysis in ASM2d overestimated phosphorous removal in the SBRs (high anaerobic hydrolysis of pCOD). The default anaerobic hydrolysis rate in BioWin 4.1 (ten times lower) could produce similar phosphorous removal to that in the experiment. Results showed that the current kinetics of anaerobic hydrolysis in ASM2d could lead to considerable error in predicting phosphorus removal in processes with extended anaerobic HRT. Biotechnol. Bioeng. 2016;113: 2377-2385. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. The Effects of a 6-Week Strength Training on Critical Velocity, Anaerobic Running Distance, 30-M Sprint and Yo-Yo Intermittent Running Test Performances in Male Soccer Players.

    Directory of Open Access Journals (Sweden)

    Bettina Karsten

    Full Text Available The objectives of this study were to examine the effects of a moderate intensity strength training on changes in critical velocity (CV, anaerobic running distance (D', sprint performance and Yo-Yo intermittent running test (Yo-Yo IR1 performances.two recreational soccer teams were divided in a soccer training only group (SO; n = 13 and a strength and soccer training group (ST; n = 13. Both groups were tested for values of CV, D', Yo-Yo IR1 distance and 30-m sprint time on two separate occasions (pre and post intervention. The ST group performed a concurrent 6-week upper and lower body strength and soccer training, whilst the SO group performed a soccer only training.after the re-test of all variables, the ST demonstrated significant improvements for both, YoYo IR1 distance (p = 0.002 and CV values (p<0.001 with no significant changes in the SO group. 30-m sprint performance were slightly improved in the ST group with significantly decreased performance times identified in the SO group (p<0.001. Values for D' were slightly reduced in both groups (ST -44.5 m, 95% CI = -90.6 to 1.6; SO -42.6 m, 95% CI = -88.7 to 3.5.combining a 6-week moderate strength training with soccer training significantly improves CV, Yo-Yo IR1 whilst moderately improving 30-m sprint performances in non-previously resistance trained male soccer players. Critical Velocity can be recommended to coaches as an additional valid testing tool in soccer.

  13. The Effects of a 6-Week Strength Training on Critical Velocity, Anaerobic Running Distance, 30-M Sprint and Yo-Yo Intermittent Running Test Performances in Male Soccer Players.

    Science.gov (United States)

    Karsten, Bettina; Larumbe-Zabala, Eneko; Kandemir, Gokhan; Hazir, Tahir; Klose, Andreas; Naclerio, Fernando

    2016-01-01

    The objectives of this study were to examine the effects of a moderate intensity strength training on changes in critical velocity (CV), anaerobic running distance (D'), sprint performance and Yo-Yo intermittent running test (Yo-Yo IR1) performances. two recreational soccer teams were divided in a soccer training only group (SO; n = 13) and a strength and soccer training group (ST; n = 13). Both groups were tested for values of CV, D', Yo-Yo IR1 distance and 30-m sprint time on two separate occasions (pre and post intervention). The ST group performed a concurrent 6-week upper and lower body strength and soccer training, whilst the SO group performed a soccer only training. after the re-test of all variables, the ST demonstrated significant improvements for both, YoYo IR1 distance (p = 0.002) and CV values (p<0.001) with no significant changes in the SO group. 30-m sprint performance were slightly improved in the ST group with significantly decreased performance times identified in the SO group (p<0.001). Values for D' were slightly reduced in both groups (ST -44.5 m, 95% CI = -90.6 to 1.6; SO -42.6 m, 95% CI = -88.7 to 3.5). combining a 6-week moderate strength training with soccer training significantly improves CV, Yo-Yo IR1 whilst moderately improving 30-m sprint performances in non-previously resistance trained male soccer players. Critical Velocity can be recommended to coaches as an additional valid testing tool in soccer.

  14. Implementing Livestock Anaerobic Digestion Projects

    Science.gov (United States)

    Page provides information to help make an informed decision about installing an anaerobic digester. Is it a good match for a farm’s organic waste, project financing, development guidelines and permit requirements?

  15. Design and Fabrication of an Anaerobic Digester

    Directory of Open Access Journals (Sweden)

    M. S. Abubakar

    2017-02-01

    Full Text Available Anaerobic digester is a physical structure that provides a conducive environment for the multiplication of micro-organisms that degrades organic matter to generate biogas energy. Energy is required in agriculture for crop production, processing and storage, poultry production and electricity for farmstead and farm settlements. It is energy that propels agricultural mechanization, which minimizes the use of human and animal muscles and its inherent drudgery in agriculture. The energy demand required to meet up with the agricultural growth in Nigeria is high and growing every year. In this study the design and fabrication of an anaerobic digester was reported which is an attempt to boost energy requirement for small and medium dryland farmers in Nigeria. The design of the digester includes the following concept; the basic principles of anaerobic digestion processes, socio-economic status of the dryland farmers, amount of biogas to be produced. Finally, the digester was fabricated using locally available raw materials within the dryland area of Nigeria. At the end, preliminary flammability test was conducted and the biogas produced was found to be flammable.

  16. Adaptação dos testes de lactato mínimo, potência crítica e limiar anaeróbio para avaliação da transição anaeróbia-anaeróbia em protocolo específico para o tênis de mesa Adaptation of the lactate minimum, critical power and anaerobic threshold tests for assessment of the aerobic/anaerobic transition in a protocol specific for table tennis

    Directory of Open Access Journals (Sweden)

    Érika Alves Morel

    2008-12-01

    correlacionado com a intensidade de fcrit (0,73. Desse modo, pode-se concluir que o teste de LACmin específico é reprodutível e que esse procedimento, assim como o teste de fcrit, pode ser aplicado para avaliar a transição aeróbia-anaeróbia no tênis de mesa e que o LAn est deve ser utilizado com cautela na avaliação de mesatenistas.The aims of the present study were to adapt the lactate minimum, critical power model and anaerobic threshold tests for assessment of the aerobic-anaerobic transition in specific test for table tennis; to verify the reproducibility of the lactate minimum test and to verify the relationship between these specific procedures with the anaerobic threshold determined in running on treadmill (AnT TR. Eleven male table tennis players participated in the study. The participants performed four tests (three specific tests and a conventional test performed on a treadmill: 1 lactate minimum test (LACmin (applied twice for reproducibility analyses - LACmim1 and LACmin2; 2 critical frequency test (critf; 3 incremental test for anaerobic threshold determination by 3.5 mM steady lactate concentration (AnT3.5 and bi-segmented linear regression (AnT BI methods, all in specific protocol; and 4 anaerobic threshold on running (AnT TR. Specific tests were applied by using a mechanical ball thrower to control the intensity of the exercise. The Bland-Altman plot, product-moment correlation and One-way ANOVA tests were used as statistical procedure, with significance level at 5%. The LACmin intensities (59.40 ± 4.06 balls.min-1 and 61.56 ± 8.97 balls.min-1 presented significant correlation (r = 0.61 and moderate concordance verified by Bland-Altman plot. The critf, AnT3.5 and AnT BI intensities corresponded to 56.50 ± 6.84 balls.min-1, 66.74 ± 5.03 balls.min-1 and 62.67 ± 7.25 balls.min-1, respectively, and only AnT3.5 and critf were different. Significant correlations were obtained amongst LACmin1 and critf (r = 0.61, LACmin2 and critf (r = 0.69, and AnT3

  17. On the kinetics of anaerobic power

    Science.gov (United States)

    2012-01-01

    Background This study investigated two different mathematical models for the kinetics of anaerobic power. Model 1 assumes that the work power is linear with the work rate, while Model 2 assumes a linear relationship between the alactic anaerobic power and the rate of change of the aerobic power. In order to test these models, a cross country skier ran with poles on a treadmill at different exercise intensities. The aerobic power, based on the measured oxygen uptake, was used as input to the models, whereas the simulated blood lactate concentration was compared with experimental results. Thereafter, the metabolic rate from phosphocreatine break down was calculated theoretically. Finally, the models were used to compare phosphocreatine break down during continuous and interval exercises. Results Good similarity was found between experimental and simulated blood lactate concentration during steady state exercise intensities. The measured blood lactate concentrations were lower than simulated for intensities above the lactate threshold, but higher than simulated during recovery after high intensity exercise when the simulated lactate concentration was averaged over the whole lactate space. This fit was improved when the simulated lactate concentration was separated into two compartments; muscles + internal organs and blood. Model 2 gave a better behavior of alactic energy than Model 1 when compared against invasive measurements presented in the literature. During continuous exercise, Model 2 showed that the alactic energy storage decreased with time, whereas Model 1 showed a minimum value when steady state aerobic conditions were achieved. During interval exercise the two models showed similar patterns of alactic energy. Conclusions The current study provides useful insight on the kinetics of anaerobic power. Overall, our data indicate that blood lactate levels can be accurately modeled during steady state, and suggests a linear relationship between the alactic

  18. Anaerobic treatment of sludge: focusing on reduction of LAS concentration in sludge

    DEFF Research Database (Denmark)

    Haagensen, Frank; Mogensen, Anders Skibsted; Angelidaki, Irini

    2002-01-01

    between transformed and bioavailable LAS12 was found, indicating that it is merely the bioavailable fraction of LAS12 that is transformed by anaerobic digestion. The results from the present study are promising and indicate that a great potential for biological degradation of LAS is possible even......Anaerobic degradation of linear alkylbenzene sulfonates (LAS) was tested in continuous stirred tank reactors (CSTR). LAS12 was used as a model compound and was spiked on sewage sludge. The experiments clearly showed that transformation of LAS12 occurred under anaerobic conditions. The degree...... at anaerobic conditions....

  19. Inactivation of ANAMMOX communities under concurrent operation of anaerobic ammonium oxidation (ANAMMOX) and denitrification

    DEFF Research Database (Denmark)

    Chamchoi, N.; Nitisoravut, S.; Schmidt, Jens Ejbye

    2008-01-01

    A concurrent operation of anaerobic ammonium oxidation (ANAMMOX) and denitrification was investigated in a well known UASB reactor seeding with both ANAMMOX and anaerobic granular sludges. ANAMMOX activity was confirmed by hydroxylamine test and the hybridization of biomass using the gene probes ...

  20. Mitigation of Humic Acid Inhibition in Anaerobic Digestion of Cellulose by Addition of Various Salts

    NARCIS (Netherlands)

    Azman, S.; Khadem, A.F.; Zeeman, G.; Van Lier, J.B.; Plugge, C.M.

    2015-01-01

    Humic compounds are inhibitory to the anaerobic hydrolysis of cellulosic biomass. In this study, the impact of salt addition to mitigate the inhibitory effects of humic compounds was investigated. The experiment was conducted using batch tests to monitor the anaerobic hydrolysis of cellulose in the

  1. Performance of an anaerobic membrane bioreactor for pharmaceutical wastewater treatment.

    Science.gov (United States)

    Svojitka, Jan; Dvořák, Lukáš; Studer, Martin; Straub, Jürg Oliver; Frömelt, Heinz; Wintgens, Thomas

    2017-04-01

    Anaerobic treatment of wastewater and waste organic solvents originating from the pharmaceutical and chemical industries was tested in a pilot anaerobic membrane bioreactor, which was operated for 580days under different operational conditions. The goal was to test the long-term treatment efficiency and identify inhibitory factors. The highest COD removal of up to 97% was observed when the influent concentration was increased by the addition of methanol (up to 25gL(-1) as COD). Varying and generally lower COD removal efficiency (around 78%) was observed when the anaerobic membrane bioreactor was operated with incoming pharmaceutical wastewater as sole carbon source. The addition of waste organic solvents (>2.5gL(-1) as COD) to the influent led to low COD removal efficiency or even to the breakdown of anaerobic digestion. Changes in the anaerobic population (e.g., proliferation of the genus Methanosarcina) resulting from the composition of influent were observed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Dynamics and genetic diversification of Escherichia coli during experimental adaptation to an anaerobic environment.

    Science.gov (United States)

    Finn, Thomas J; Shewaramani, Sonal; Leahy, Sinead C; Janssen, Peter H; Moon, Christina D

    2017-01-01

    Many bacteria are facultative anaerobes, and can proliferate in both anoxic and oxic environments. Under anaerobic conditions, fermentation is the primary means of energy generation in contrast to respiration. Furthermore, the rates and spectra of spontaneous mutations that arise during anaerobic growth differ to those under aerobic growth. A long-term selection experiment was undertaken to investigate the genetic changes that underpin how the facultative anaerobe, Escherichia coli, adapts to anaerobic environments. Twenty-one populations of E. coli REL4536, an aerobically evolved 10,000th generation descendent of the E. coli B strain, REL606, were established from a clonal ancestral culture. These were serially sub-cultured for 2,000 generations in a defined minimal glucose medium in strict aerobic and strict anaerobic environments, as well as in a treatment that fluctuated between the two environments. The competitive fitness of the evolving lineages was assessed at approximately 0, 1,000 and 2,000 generations, in both the environment of selection and the alternative environment. Whole genome re-sequencing was performed on random colonies from all lineages after 2,000-generations. Mutations were identified relative to the ancestral genome, and based on the extent of parallelism, traits that were likely to have contributed towards adaptation were inferred. There were increases in fitness relative to the ancestor among anaerobically evolved lineages when tested in the anaerobic environment, but no increases were found in the aerobic environment. For lineages that had evolved under the fluctuating regime, relative fitness increased significantly in the anaerobic environment, but did not increase in the aerobic environment. The aerobically-evolved lineages did not increase in fitness when tested in either the aerobic or anaerobic environments. The strictly anaerobic lineages adapted more rapidly to the anaerobic environment than did the fluctuating lineages. Two main

  3. Anaerobic benzene degradation by bacteria

    Science.gov (United States)

    Vogt, Carsten; Kleinsteuber, Sabine; Richnow, Hans‐Hermann

    2011-01-01

    Summary Benzene is a widespread and toxic contaminant. The fate of benzene in contaminated aquifers seems to be primarily controlled by the abundance of oxygen: benzene is aerobically degraded at high rates by ubiquitous microorganisms, and the oxygen‐dependent pathways for its breakdown were elucidated more than 50 years ago. In contrast, benzene was thought to be persistent under anoxic conditions until 25 years ago. Nevertheless, within the last 15 years, several benzene‐degrading cultures have been enriched under varying electron acceptor conditions in laboratories around the world, and organisms involved in anaerobic benzene degradation have been identified, indicating that anaerobic benzene degradation is a relevant environmental process. However, only a few benzene degraders have been isolated in pure culture so far, and they all use nitrate as an electron acceptor. In some highly enriched strictly anaerobic cultures, benzene has been described to be mineralized cooperatively by two or more different organisms. Despite great efforts, the biochemical mechanism by which the aromatic ring of benzene is activated in the absence of oxygen is still not fully elucidated; methylation, hydroxylation and carboxylation are discussed as likely reactions. This review summarizes the current knowledge about the ‘key players’ of anaerobic benzene degradation under different electron acceptor conditions and the possible pathway(s) of anaerobic benzene degradation. PMID:21450012

  4. Electrochemical monitoring of ammonia during anaerobic digestion

    DEFF Research Database (Denmark)

    Zhao, Nannan; Angelidaki, Irini; Zhang, Yifeng

    Ammonia is known as key inhibitor to methanogens in anaerobic digestion (AD) process. It’s of importance to develop efficient tool for ammonia monitoring. In this study, an electrolysis cell (EC) coupled with a complete nitrification reactor was developed as sensor for real time and online......-rich digesters. It was observed that the initial transient currents (0 min) were linearly corresponding to the ammonia levels (from 0 to 95.75 mg/L NH4+-N, R2 = 0.9673). Finally, this new sensor was tested with real AD effluent and the results showed no significant difference with that measured by conventional...

  5. Diurnal variations in physical performances related to football in young soccer players.

    Science.gov (United States)

    Chtourou, Hamdi; Hammouda, Omar; Souissi, Hichem; Chamari, Karim; Chaouachi, Anis; Souissi, Nizar

    2012-09-01

    This study investigated the effects of time-of-day on aerobic and anaerobic performances during the Yo-Yo, repeated sprint ability (RSA) and the Wingate tests in young soccer players. In a counterbalanced and a random order, twenty junior male soccer players completed the Yo-Yo, the RSA, and the Wingate tests at two different times-of-day: 07:00 and 17:00 h. During the Yo-Yo test, the total distance (TD) covered and the estimated maximal aerobic velocity (MAV) were determined. The peak power (PP) during each sprint, the percentage of decrement of PP (PD) and total work (Wtotal) during the RSA test were, also, measured. In addition, during the Wingate test, the peak (P(peak)) and mean (P(mean)) powers were recorded. During the Wingate test, P(peak) and P(mean) were significantly higher at 17:00 than 07:00 h (Psoccer players.

  6. Anaerobic bacteria colonizing the lower airways in lung cancer patients

    Directory of Open Access Journals (Sweden)

    Anna Malm

    2011-07-01

    Full Text Available Anaerobes comprise most of the endogenous oropharyngeal microflora, and can cause infections of airways in lung cancer patients who are at high risk for respiratory tract infections. The aim of this study was to determine the frequency and species diversity of anaerobes in specimens from the lower airways of lung cancer patients. Sensitivity of the isolates to conventional antimicrobial agents used in anaerobe therapy was assessed. Respiratory secretions obtained by bronchoscopy from 30 lung cancer patients were cultured onto Wilkins- -Chalgren agar in anaerobic conditions at 37°C for 72–96 hours. The isolates were identified using microtest Api 20A. The minimal inhibitory concentrations for penicillin G, amoxicillin/clavulanate, piperacillin/tazobactam, cefoxitin, imipenem, clindamycin, and metronidazole were determined by E-test. A total of 47 isolates of anaerobic bacteria were detected in 22 (73.3% specimens. More than one species of anaerobe was found in 16 (53.3% samples. The most frequently isolated were Actinomyces spp. and Peptostreptococcus spp., followed by Eubacterium lentum, Veillonella parvula, Prevotella spp., Bacteroides spp., Lactobacillus jensenii. Among antibiotics used in the study amoxicillin/clavulanate and imipenem were the most active in vitro (0% and 2% resistant strains, respectively. The highest resistance rate was found for penicillin G and metronidazole (36% and 38% resistant strains, respectively. The results obtained confirm the need to conduct analyses of anaerobic microflora colonizing the lower respiratory tract in patients with lung cancer to monitor potential etiologic factors of airways infections, as well as to propose efficient, empirical therapy. (Folia Histochemica et Cytobiologica 2011; Vol. 49, No. 2, pp. 263–266

  7. Testing low cost anaerobic digestion (AD) systems

    Science.gov (United States)

    To evaluate the potential for low technology and low cost digesters for small dairies, BARC and researchers from the University of Maryland installed six modified Taiwanese-model field-scale (FS) digesters near the original dairy manure digester. The FS units receive the same post-separated liquid ...

  8. Anaerobic digestion of solid material

    DEFF Research Database (Denmark)

    Vavilin, V.A.; Lokshina, L.Y.; Flotats, X.

    2007-01-01

    A new multidimensional (3 and 2D) anaerobic digestion model for cylindrical reactor with non-uniform influent concentration distributions was developed to study the way in which mixing intensity affects the efficiency of continuous-flow anaerobic digestion. Batch experiments reported and simulated....... In the system, the threshold methanogenic biomass concentration existed because of inhibition by high VFA concentration. High methanogenic biomass concentration is required for efficient anaerobic digestion of MSW in order to avoid possible inhibition due to high VFA build-up. Thus, CSTR configuration might...... have unstable dynamics at high organic loading as shown in earlier experiments carried out by Stroot et al. (2001). A gradual increase of organic loading during the start up of a completely mixed digester causing an accumulation of methanogenic biomass is a solution to prevent a probable digester...

  9. Comparative evaluation of anaerobic biodegradability of hydrocarbons and fatty derivatives currently used as drilling fluids.

    Science.gov (United States)

    Steber, J; Herold, C P; limia, J M

    1995-08-01

    The examination of a number of potential and currently used carrier fluids for invert emulsion drilling fluids in the ECETOC screening test revealed clear differences with respect to their easy anaerobic biodegradability. Fatty acid- and alcohol-based ester oils exhibited excellent anaerobic degradation to the gaseous final end products of the methanogenic degradation pathway, methane and carbon dioxide. Mineral oils, dialkyl ethers, alpha-olefins, polyalphaolefins, linear alkylbenzenes and an acetal-derivative were not or only slowly degraded. Although the poor degradation results obtained in the stringent ECETOC screening test may not be regarded as final proof of anaerobic recalcitrance, nevertheless, these results were found to be in line with the present understanding of the structural requirements for anaerobic biodegradability of chemicals. The validity of the conclusions drawn is corroborated by published results on the anaerobic biodegradation behaviour of ester oils, mineral oils and alkylbenzenes in marine sediments.

  10. Effects of kinesio taping on anaerobic power recovery after eccentric exercise.

    Science.gov (United States)

    Szymura, Jadwiga; Maciejczyk, Marcin; Wiecek, Magdalena; Maciejczyk, Grzegorz; Wiecha, Szczepan; Ochalek, Katarzyna; Kepinska, Magdalena; Szygula, Zbigniew

    2016-01-01

    The aim of the study was to evaluate the effectiveness of kinesio taping (KT) in anaerobic power recovery after eccentric exercise. The study was carried out on 10 healthy men. The participants performed two 60-min downhill runs with a constant intensity. Peak anaerobic power (PP) and mean power (MP) were measured before and five times after eccentric exercise. Anaerobic power was evaluated with the Maximal Cycling Sprint Test. After the downhill run, passive recovery (PR) and KT (lymphatic application) were applied in random order. A significant decrease in PP and MP was observed at least for 24 h after PR, compared to baseline. After the KT application 24 h after eccentric exercises, anaerobic power was already similar to the baseline measurement. The application of KT significantly improved anaerobic power recovery time after eccentric exercise compared to the period of passive rest immediately prior to testing.

  11. RISK FACTORS IN NEONATAL ANAEROBIC INFECTIONS

    Directory of Open Access Journals (Sweden)

    M. S. Tabib

    2008-06-01

    Full Text Available Anaerobic bacteria are well known causes of sepsis in adults but there are few studies regarding their role in neonatal sepsis. In an attempt to define the incidence of neonatal anaerobic infections a prospective study was performed during one year period. A total number of 400 neonates under sepsis study were entered this investigation. Anaerobic as well as aerobic cultures were sent. The patients were subjected to comparison in two groups: anaerobic culture positive and anaerobic culture negative and this comparison were analyzed statistically. There were 7 neonates with positive anaerobic culture and 35 neonates with positive aerobic culture. A significant statistical relationship was found between anaerobic infections and abdominal distention and pneumonia. It is recommended for those neonates with abdominal distention and pneumonia refractory to antibiotic treatment to be started on antibiotics with anaerobic coverage.

  12. Instrumentation in anaerobic treatment - research and practice

    NARCIS (Netherlands)

    Spanjers, H.; Lier, van J.B.

    2006-01-01

    High rate anaerobic treatment reactors are able to uncouple solids and liquid retention time, resulting in high biomass concentrations. Principal advantages of anaerobic treatment include: energy efficiency, low biomass yield, low nutrient requirement and high volumetric organic loadings. In order

  13. Comparison of Effect of One Course of Intense Exercise (Wingate test) on Serum Levels of Interleukin-17 in Different Groups of Athletes

    OpenAIRE

    Tofighee, Asghar; Khazaei, Hossein Ali; Jalili, Arman

    2014-01-01

    Background: Research on the effects of exercise on immune function, has a wide range of sporting activities. Study on the long-term effects of regular exercise on serum levels of cytokines such as interleukin-17 have shown that moderate and regular exercise, has an important role in the prevention and treatment of many diseases. Objectives: Exhaustive exercise has a deep effect on cellular, humoral, innate immunity and the amount of cytokines of an athlete?s immune system. So this study was d...

  14. Peak oxygen uptake and ventilatory anaerobic threshold in fibromyalgia.

    Science.gov (United States)

    Valim, Valéria; Oliveira, Leda M; Suda, Alina L; Silva, Luciana E; Faro, Mário; Neto, Turíbio L Barros; Feldman, Daniel; Natour, Jamil

    2002-02-01

    To compare maximum oxygen uptake and anaerobic threshold in patients with fibromyalgia (FM) and healthy sedentary controls matched by sex, age, weight, and body mass index. Fifty women with FM aged 18-60 years and 50 healthy sedentary controls were studied. All were submitted to a maximum treadmill incremental test. Expired gas, ventilatory anaerobic threshold, and maximum oxygen uptake (VO2max) were evaluated. The influence of FM on quality of life was evaluated by questionnaires: the Fibromyalgia Impact Questionnaire and the Medical Outcomes Study Short-Form (SF-36). In patients with FM, the anaerobic threshold and peak oxygen uptake were significantly reduced. Maximum heartbeat rate was significantly lower in FM, indicating submaximum effort. Linear regression data showed a correlation between peak VO2 and the "Role-physical" domain of the SF-36. No such correlations were noted with anaerobic threshold. These results confirm the hypothesis of lower physical fitness in patients with FM. Considering that patients with FM do not achieve a maximum effort, ventilatory anaerobic threshold should be considered as a better fitness index than VO2max.

  15. 21 CFR 866.2120 - Anaerobic chamber.

    Science.gov (United States)

    2010-04-01

    ... and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices § 866.2120 Anaerobic chamber. (a) Identification. An anaerobic chamber is a device intended for medical purposes to maintain an anaerobic (oxygen...

  16. The phenomenon of granulation of anaerobic sludge

    NARCIS (Netherlands)

    Hulshoff Pol, L.

    1989-01-01

    Successful high-rate anaerobic wastewater treatment can only be accomplished when the slowgrowing anaerobic biomass is efficiently held back in the anaerobic treatment system. This biomass retention can be achieved in various ways including immobilization of the organisms on fixed materials

  17. Methanization potential of anaerobic biodigestion of solid food waste

    Directory of Open Access Journals (Sweden)

    Laís R. G. de Oliveira

    Full Text Available ABSTRACT Anaerobic biodigestion of solid and semi-solid wastes has been widely used for the treatment of these residues and methane production; however, during the process (more specifically in the acidogenic phase, there is a tendency of pH reduction, an unfavorable condition to methanogenic bacteria. Thus, the present work aims to evaluate the methanization potential of an agroindustrial anaerobic granular sludge (AIS from UASB (Upflow Anaerobic Sludge Blanket reactor, individually and biodigested with food waste (FW from the University Restaurant of the Federal University of Pernambuco with buffering agent (AIS + FW + b and without it (AIS + FW. After the laboratory tests, the AIS + FW + b configuration obtained a cumulative methane production approximately six times greater than that of AIS + FW, and approximately twice that of the inoculum alone (AIS.

  18. Anaerobic and aerobic acetylene hydratase

    Indian Academy of Sciences (India)

    Administrator

    The first step of the fermentation pathway, the hydration of acetylene to acetaldehyde, is catalyzed by the enzyme, acetylene hydratase. A detailed biochemical assay on these systems showed that the anaerobic strain, WoAcy 1, from Palobacter acetylinicus possesses a tungsten-containing acetylene hydratase but the ...

  19. Anaerobic granular sludge and biofilm reactors

    DEFF Research Database (Denmark)

    Skiadas, Ioannis V.; Gavala, Hariklia N.; Schmidt, Jens Ejbye

    2003-01-01

    by the immobilization of the biomass, which forms static biofilms, particle-supported biofilms, or granules depending on the reactor's operational conditions. The advantages of the high-rate anaerobic digestion over the conventional aerobic wastewater treatment methods has created a clear trend for the change......-rate anaerobic treatment systems based on anaerobic granular sludge and biofilm are described in this chapter. Emphasis is given to a) the Up-flow Anaerobic Sludge Blanket (UASB) systems, b) the main characteristics of the anaerobic granular sludge, and c) the factors that control the granulation process...

  20. Mental fatigue does not affect maximal anaerobic exercise performance.

    Science.gov (United States)

    Martin, Kristy; Thompson, Kevin G; Keegan, Richard; Ball, Nick; Rattray, Ben

    2015-04-01

    Mental fatigue can negatively impact on submaximal endurance exercise and has been attributed to changes in perceived exertion rather than changes in physiological variables. The impact of mental fatigue on maximal anaerobic performance is, however, unclear. Therefore, the aim of the present study was to induce a state of mental fatigue to examine the effects on performance, physiological and perceptual variables from subsequent tests of power, strength and anaerobic capacity. Twelve participants took part in the single-blind, randomised, crossover design study. Mental fatigue was induced by 90 min of the computer-based Continuous Performance Task AX version. Control treatment consisted of 90 min of watching emotionally neutral documentaries. Participants consequently completed countermovement jump, isometric leg extension and a 3-min all-out cycling tests. Results of repeated measures analysis of variance and paired t tests revealed no difference in any performance or physiological variable. Rating of perceived exertion tended to be greater when mentally fatigued (mental fatigue = 19 ± 1 vs control = 18 ± 1, p = 0.096, [Formula: see text] = .232) and intrinsic motivation reduced (mental fatigue = 11 ± 4 vs control = 13 ± 6, p = 0.063, d = 0.597) in the mental fatigue condition. Near identical responses in performance and physiological parameters between mental fatigue and control conditions suggest that peripheral mechanisms primarily regulate maximal anaerobic exercise. Whereas mental fatigue can negatively impact submaximal endurance exercise, it appears that explosive power, voluntary maximal strength and anaerobic work capacity are unaffected.

  1. Geochemical evidence of groundwater flow paths and the fate and transport of constituents of concern in the alluvial aquifer at Fort Wingate Depot Activity, New Mexico, 2009

    Science.gov (United States)

    Robertson, Andrew J.; Henry, David W.; Langman, Jeffery B.

    2013-01-01

    As part of an environmental investigation at Fort Wingate Depot Activity, New Mexico, the U.S. Geological Survey, in cooperation with the U.S. Army Corps of Engineers, interpreted aqueous geochemical concentrations to better understand the groundwater flow paths and the fate and transport of constituents of concern in the alluvial aquifer underlying the study area. The fine-grained nature of the alluvial matrix creates a highly heterogeneous environment, which adds to the difficulty of characterizing the flow of groundwater and the fate of aqueous constituents of concern. The analysis of the groundwater geochemical data collected in October 2009 provides evidence that is used to identify four groundwater flow paths and their extent in the aquifer and indicates the dominant attenuation processes for the constituents of concern. The extent and interaction of groundwater flow paths were delineated by the major ion concentrations and their relations to each other. Four areas of groundwater recharge to the study area were identified based on groundwater elevations, hydrogeologic characteristics, and geochemical and isotopic evidence. One source of recharge enters the study area from the saturated alluvial deposits underlying the South Fork of the Puerco River to the north of the study area. A second source of recharge is shown to originate from a leaky cistern containing production water from the San Andres-Glorieta aquifer. The other two sources of recharge are shown to enter the study area from the south: one from an arroyo valley draining an area to the south and one from hill-front recharge that passes under the reported release of perchlorate and explosive constituents. The spatial extent and interaction of groundwater originating from these various sources along identified flow paths affect the persistence and attenuation of constituents of concern. It was determined that groundwater originating in the area of a former explosives’ wash-out operation and an

  2. Hydroponic system for the treatment of anaerobic liquid.

    Science.gov (United States)

    Krishnasamy, K; Nair, J; Bäuml, B

    2012-01-01

    The effluent from anaerobic digestion process has high concentrations of nutrients, particularly nitrogen, essential for plant growth but is not suitable for direct disposal or application due to high chemical oxygen demand (COD), low dissolved oxygen (DO), odour issues and is potentially phytotoxic. This research explored the optimum conditions of anaerobic effluent for application and dilutions of the effluent required to obtain better plant growth. A small-scale hydroponic system was constructed in a glasshouse to test different concentrations of anaerobic effluent against a commercial hydroponic medium as the control for the growth of silverbeet. It was found that the survival of silverbeet was negatively affected at 50% concentration due to low DO and NH(4) toxicity. The concentration of 20% anaerobic liquid was found to be the most efficient with highest foliage yield and plant growth. The hydroponic system with 20% concentrated effluent had better utilisation of nutrients for plant growth and a COD reduction of 95% was achieved during the 50-day growth period. This preliminary evaluation revealed that the growth and development of silverbeet was significantly lower in anaerobic effluent compared with a commercial hydroponic plant growth solution. The nutrient quality of anaerobic effluent could be highly variable with the process and the waste material used and dilution may depend on the nutrient content of the effluent. It is recommended that, a pre-treatment of the effluent to increase DO and reduce ammonium content is required before plant application, and simple dilution by itself is not suitable for optimum plant growth in a hydroponic system.

  3. The Relationship Between Aerobic and Anaerobic Performance in Recreational Runners.

    Science.gov (United States)

    Gillen, Zachary M; Wyatt, Frank B; Winchester, Jason B; Smith, Dalton A; Ghetia, Vidhi

    2016-01-01

    Research has indicated that combined aerobic and anaerobic training (concurrent training) may improve aerobic performance greater than aerobic training alone. The purpose of this investigation was to establish any associations between aerobic and anaerobic performance. Eleven participants (n = 11, age = 34.1 ± 13 years, VO2max = 58.4 ± 7.8) volunteered for this study. Participants were asked for endurance training experience (4.7 ± 3.7 years) and resistance training experience (4.1 ± 4.6 years). To meet training status, participants were to have a VO2max in the 80th percentile as per ACSM guidelines. The Bruce treadmill test was used to measure aerobic performance. In order to measure anaerobic performance, several tests were completed utilizing a force platform. A Pearson Product R Correlation Coefficient was calculated to determine correlations between variables. The results show significant correlation between VO2max and RFD (r = 0.68). Further analyses utilizing Cohen's effect size indicated a strong association between VO2max and peak force, as well as running efficiency and peak power, relative peak power, and power endurance. These results indicate an existing possibility that anaerobic performance measures such as RFD may have a positive relationship with aerobic performance measures such as VO2max. Therefore, it may be beneficial to integrate specific training components which focus on improving RFD as a method of improving running performance.

  4. Preparation of prereduced anaerobically sterilized media and their use in cultivation of anaerobic bacteria.

    Science.gov (United States)

    Chan, E C; deVries, J; Harvey, R F

    1978-08-01

    Several modifications of the roll-tube method have made it simpler for routine use in the isolation and growth of anaerobic bacteria. These include use of a check valve for the production of prereduced anaerobically sterilized media; a Salvarsan tube under oxygen-free gas pressure for the dispensing of molten prereduced anaerobically sterilized agar medium; a Kelly infusion bottle with a graduated pipette side arm (also under gas pressure) for quantitative delivery of fluid prereduced anaerobically sterilized media; and screw-capped prescription bottles for the cultivation of anaerobes. Colonies of Bacteroides melaninogenicus were easily identified and counted by this method. Other anaerobic bacteria have also been cultivated successfully.

  5. ADM1-based modeling of anaerobic digestion of swine manure fibers pretreated with aqueous ammonia soaking

    OpenAIRE

    Jurado, Esperanza; Gavala, Hariklia N.; Skiadas, Ioannis

    2012-01-01

    Anaerobic digestion of manure fibers present challenges due to their low biodegradability. Aqueous ammonia soaking (AAS) and subsequent ammonia removal has been tested as a simple and cheap method to disrupt the lignocellulose and increase the methane potential and the biogas productivity of manure fibers. In the present study, mesophilic anaerobic digestion of AAS pretreated manure fibers was tested in CSTR-type digesters fed with swine manure and/or a mixture of swine manure and AAS pretrea...

  6. The Relationship Between Endurance Of Periscapular Muscles, Anaerobic Performance And Agility In Professional Athletes

    OpenAIRE

    Zorlular, Ali; ?obano?lu, Gamze; Keklik, Sinem Suner; G?kdo?an, ?a?atay M?slim; Akaras, Esedullah; Polat, Elif Ayg?n; Kafa, Nihan; G?zel, Nevin Atalay

    2017-01-01

    Objective: The purpose of this study was to identify relationships between endurance of periscapular muscle, anaerobic performance and agility in professional athletes. Methods: 70 professional basketball, volleyball, and handball players (male: 25 female: 45 age 20.41?5.72, BMI: 21.70?2.51) were included to this study. Anaerobic performance was assessed with vertical jump test. Periscapular muscles endurance was evaluated using scapular muscle endurance test and agility was measured hexagona...

  7. Anaerobic glycolysis and lymphocytes blastization.

    Science.gov (United States)

    Mazzuca, A

    1980-01-30

    The role of enhanced anaerobic glycolysis in the transformation of human peripheral lymphocytes induced by mitogens has been investigated. The DNA syntesis, lactate production and increment of lactate dehydrogenase isoenzyme 5 (LDH5) have been studied. In this paper we present detailed kinetic studies, which indicate that LDH5 increment correlates closely with rapid synthetic activity and is not morely part of an overall increase in enzymatic activities.

  8. Anaerobic Degradation of Phenolic Compounds

    OpenAIRE

    Schink, Bernhard; Philipp, Bodo; Jochen A Müller

    2000-01-01

    Mononuclear aromatic compounds are degraded anaerobically through three main pathways, the benzoyl-CoA pathway, the resorcinol pathway, and the phloroglucinol pathway. Various modification reactions channel a broad variety of mononuclear aromatics including aromatic hydrocarbons into either one of these three pathways. Recently, a further pathway was discovered with hydroxyhydroquinone as central intermediate through which especially nitrate-reducing bacteria degrade phenolic compounds and so...

  9. Anaerobic work capacity in elite wheelchair athletes.

    Science.gov (United States)

    van der Woude, L H; Bakker, W H; Elkhuizen, J W; Veeger, H E; Gwinn, T

    1997-01-01

    To study the anaerobic work capacity in wheelchair athletes, 67 elite wheelchair athletes (50 male) were studied in a 30-second sprint test on a computer-controlled wheelchair ergometer during the World Championships and Games for the Disabled in Assen (1990). The experimental set-up (ergometer, protocol) proved to be adequate in terms of power output (P30, P5) velocity and heart rate. Male and female athletes were comparable with respect to personal characteristics (age, body weight, training hours). Track athletes (classified in 4 different functional classes) showed a class-related mean power output (P30: mean power produced during the 30-second sprint period) of 23, 68, 100, and 138 W for the male athletes (n = 38) and 38, 77, and 76 W for females in the upper three classes (n = 10). Sprint power was low for the group of subjects with cerebral palsy (35 W; mixed, n = 6) and relatively high for the amputee group (121 W; mixed, n = 6), female basketball players (81 W; n = 5), and two male field athletes (110 W). Significant differences between male and female athletes were found for P30 and P5 (highest mean power output over any of the six 5-second periods). As was to be expected, mean maximum heart rate in the sprint test varied significantly between the track groups from 112 (high lesion group) to 171 beats/minute(-1) (low lesion group) but not for both genders. The lower P30 in the T1 and T2 groups must be explained not only by the reduced functional muscle mass and impaired coordination but also by phenomena of cardiovascular dysfunction. Based on the performance parameters, the functional classification of the track athletes into four groups seems adequate. P30 was significantly associated with the personal characteristics of gender and hours of training. A significant correlation was found between P30 and sprint performance times for 200 meters (r = -0.79). No correlation was found between either of the forms of power output and the marathon times

  10. Comparison of the Anaerobic Power of Brazilian Professional Football Players Grouped by Tactical Position

    Directory of Open Access Journals (Sweden)

    Renan Renato Cruz dos Santos

    2014-09-01

    Full Text Available Football is characterized as a predominately aerobic modality, however, during a match; the most important actions performed by the players are in short duration and high intensity. In addition, this sport presents to have some particularities, such as, highlights differences of each tactical position. Thus, this study aimed to compare the anaerobic power of professional football players grouped by different tactical positions. Thirty professional football players separated in three groups, goal¬keep¬ers+fullbacks, sideways+DMF (defensive middlefields and OMF (offensive middlefields+forwards, performed two anaerobic po¬wer tests, Running anaerobic sprint test and Sargent jump test Goalkeepers+fullbacks showed higher values of body mass index and absolute anaerobic power (w, using Sargent jump test than the others, but when analyzed the RAST results, this same group presented lower values (p<0.05 of relative AP (w∙kg-1. OMF+forwards showed to have the best Pmed and Pmax values (p<0.05, when compared with defensive players. These results suggest the use of running anaerobic sprint test and sargent jump test toge¬ther when is proposed to measure the anaerobic power of football players, and also a anthropometric evaluation, so the training can be more specific e efficient to each tactical position and athlete.

  11. Effects of aerobic and anaerobic exercise on spatial learning ability in hypothyroid rats: a pilot study.

    Science.gov (United States)

    Park, Sung-Hyun; Song, MinYoung

    2016-12-01

    [Purpose] This pilot study analyzed the degradation of spatial learning ability caused by hypothyroidism using aerobic and anaerobic exercise. [Subjects and Methods] The experiments were performed on 11, four-week-old male Sprague-Dawley rats. Hypothyroidism-induced rats receiving propylthiouracil (PTU) treatment were divided into aerobic exercise, anaerobic exercise, and control groups. Each group performed exercise and rest for four weeks. Changes in lethargy, memory deterioration, and thyroid function were measured in each group by blood analysis and open field and Morris water maze tests. [Results] After four weeks, blood analysis revealed that the thyroid hormone levels had returned to normal in the aerobic exercise, anaerobic exercise, and control groups, whereas the open field and Morris water maze tests showed that the aerobic and anaerobic exercise groups had faster recovery compared to that of the control group. In addition, comparison of aerobic and anaerobic groups showed that the anaerobic exercise group had faster recovery compared to that of the aerobic group. [Conclusion] The findings of this study suggest that exercise helped to improve lethargy and deteriorated spatial learning ability caused by hypothyroidism and to recover function in rats. Anaerobic exercise was more beneficial than aerobic exercise in alleviating symptoms.

  12. Anaerobic bacteraemia: a review of 17 cases.

    Directory of Open Access Journals (Sweden)

    Anuradha D

    1998-07-01

    Full Text Available Of 93 blood cultures received with a suspicion of anaerobic bacteraemia over a period of two years, only 17 (18.3% showed anaerobic growth. Twelve grew anaerobes alone while five had a polymicrobial flora. Seven of these patients (4.3% had pre-existing heart disease while others had history of prior surgery, diabetes mellitus or urinary tract infection. Oropharynx was the commonest portal of entry, followed by gastrointestinal tract. The anaerobes isolated were anaerobic streptococci, Bacteroides fragilis group and Bilophila and Eubacterium species. Fifteen patients developed major complications such as congestive cardiac failure, systemic embolisation, and perforative peritonitis. The mortality rate among the cases with anaerobic bacteraemia was 23.5% in this study.

  13. Application of dynamic membranes in anaerobic membranes in anaerobic membrane bioreactor systems

    NARCIS (Netherlands)

    Erşahin, M.E.

    2015-01-01

    Anaerobic membrane bioreactors (AnMBRs) physically ensure biomass retention by the application of a membrane filtration process. With growing application experiences from aerobic membrane bioreactors (MBRs), the combination of membrane and anaerobic processes has received much attention and become

  14. An Experimental Protocol to Model Recovery of Anaerobic Work Capacity

    Directory of Open Access Journals (Sweden)

    Vijay Sarthy M. Sreedhara

    2018-02-01

    Full Text Available Models of fatigue are based on physiological parameters such as Critical Power (CP and Anaerobic Work Capacity (AWC. CP is a theoretical threshold value that a human can generate for an indefinite amount of time and AWC represents a finite expendable amount of anaerobic energy at intensities above CP. There is an increasing interest in developing mathematical models of energy expenditure and recovery for athletic training and human performance. The objective of this research is to propose and validate a model for recovery of AWC during a post exertion recovery interval of cycling. A cycling ergometer study is proposed which involves a VO2max ramp test to determine gas exchange threshold, a 3-min all-out intensity test to determine CP and AWC, and exertion-recovery interval tests to understand recovery of AWC. The results will be used to build a human in the loop control system to optimize cycling performance.

  15. Enhanced biogas yield from energy crops with rumen anaerobic fungi

    Energy Technology Data Exchange (ETDEWEB)

    Prochazka, Jindrich; Zabranska, Jana; Dohanyos, Michal [Department of Water Technology and Environmental Engineering, Faculty of Environmental Technology, Institute of Chemical Technology in Prague, Prague (Czech Republic); Mrazek, Jakub; Strosova, Lenka; Fliegerova, Katerina [Laboratory of Anaerobic Microbiology, Institute of Animal Physiology and Genetics, CAS, v.v.i., Prague (Czech Republic)

    2012-06-15

    Anaerobic fungi (AF) are able to degrade crop substrates with higher efficiency than commonly used anaerobic bacteria. The aim of this study was to investigate ways of use of rumen AF to improve biogas production from energy crops under laboratory conditions. In this study, strains of AF isolated from feces or rumen fluid of cows and deer were tested for their ability to integrate into the anaerobic bacterial ecosystem used for biogas production, in order to improve degradation of substrate polysaccharides and consequently the biogas yield. Batch culture, fed batch culture, and semicontinuous experiments have been performed using anaerobic sludge from pig slurry fermentation and different kinds of substrates (celluloses, maize, and grass silage) inoculated by different genera of AF. All experiments showed a positive effect of AF on the biogas yield and quality. AF improved the biogas production by 4-22%, depending on the substrate and AF species used. However, all the cultivation experiments indicated that rumen fungi do not show long-term survival in fermenters with digestate from pig slurry. The best results were achieved during fed batch experiment with fungal culture Anaeromyces (KF8), in which biogas production was enhanced during the whole experimental period of 140 days. This result has not been achieved in semicontinuous experiment, where increment in biogas production in fungal enriched reactor was only 4% after 42 days. (copyright 2012 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  16. Relating methanogen community structure and anaerobic digester function.

    Science.gov (United States)

    Bocher, B T W; Cherukuri, K; Maki, J S; Johnson, M; Zitomer, D H

    2015-03-01

    Much remains unknown about the relationships between microbial community structure and anaerobic digester function. However, knowledge of links between community structure and function, such as specific methanogenic activity (SMA) and COD removal rate, are valuable to improve anaerobic bioprocesses. In this work, quantitative structure-activity relationships (QSARs) were developed using multiple linear regression (MLR) to predict SMA using methanogen community structure descriptors for 49 cultures. Community descriptors were DGGE demeaned standardized band intensities for amplicons of a methanogen functional gene (mcrA). First, predictive accuracy of MLR QSARs was assessed using cross validation with training (n = 30) and test sets (n = 19) for glucose and propionate SMA data. MLR equations correlating band intensities and SMA demonstrated good predictability for glucose (q(2) = 0.54) and propionate (q(2) = 0.53). Subsequently, data from all 49 cultures were used to develop QSARs to predict SMA values. Higher intensities of two bands were correlated with higher SMA values; high abundance of methanogens associated with these two bands should be encouraged to attain high SMA values. QSARs are helpful tools to identify key microorganisms or to study and improve many bioprocesses. Development of new, more robust QSARs is encouraged for anaerobic digestion or other bioprocesses, including nitrification, nitritation, denitrification, anaerobic ammonium oxidation, and enhanced biological phosphorus removal. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Biological Phosphorus Release and Uptake Under Alternating Anaerobic and Anoxic Conditions In a Fixed-Film Reactor

    DEFF Research Database (Denmark)

    Kerrn-Jespersen, Jens Peter; Henze, Mogens; Strube, Rune

    1994-01-01

    Biological phosphorus removal was investigated in a fixed-film reactor with alternating anaerobic and anoxic conditions. The tests showed that biological phosphorus removal can be obtained in a fixed-film reactor with nitrate as oxidising agent. In the anaerobic period, 0.52 mg of PO4-P...

  18. Effects of gamma ray and electron-beam irradiations on survival of anaerobic and facultatively anaerobic bacteria

    Energy Technology Data Exchange (ETDEWEB)

    Miyahara, Michiko; Miyahara, Makoto [National Inst. of Health Sciences, Tokyo (Japan)

    2002-10-01

    An extension of the approval for food irradiation is desired due to the increase in the incidence of food poisoning in the world. One anaerobic (Clostridium perfringens) and four facultatively anaerobic (Bacillus cereus, Escherichia coli O157:H7, Listeria monocytogenes, and Salmonella Enteritidis) bacteria irradiated with gamma ray or electron beam (E-beam) were tested in terms of survival on agar under packaging atmosphere. Using pouch pack, effects of two irradiations on survival of anaerobic and facultatively anaerobic bacteria were evaluated comparatively. E-beam irradiation was more effective than gamma ray irradiation in decreasing the lethal dose 10% (D{sub 10}) value of B. cereus at 4 deg C, slightly more effective in that of E. coli O157, and similarly effective in that of the other three bacteria at 4 deg C. The gamma irradiation of the bacteria without incubation at 4 deg C before irradiation was more effective than that of the bacteria with incubation overnight at 4 deg C before irradiation in decreasing the D10 values of these bacteria (B. cereus, E. coli O157, and L. monocytogenes). Furthermore, ground beef patties inoculated with bacteria were irradiated with 1 kGy by E-beam (5 MeV) at 4 deg C. The inoculated bacteria in the 1-9 mm beef patties were killed by 1 kGy E-beam irradiation and some bacteria in more than 9 mm beef patties were not killed by the irradiation. (author)

  19. ADM1-based modeling of anaerobic digestion of swine manure fibers pretreated with aqueous ammonia soaking

    DEFF Research Database (Denmark)

    Jurado, Esperanza; Gavala, Hariklia N.; Skiadas, Ioannis

    2012-01-01

    that the AAS had on the efficiency of the anaerobic digestion of manure. Kinetic parameters were estimated by fitting of the model to data from manure fed digesters. The model was able to satisfactorily simulate the behaviour of digesters fed with manure. However, the model predictions were poorer......Anaerobic digestion of manure fibers present challenges due to their low biodegradability. Aqueous ammonia soaking (AAS) and subsequent ammonia removal has been tested as a simple and cheap method to disrupt the lignocellulose and increase the methane potential and the biogas productivity of manure...... fibers. In the present study, mesophilic anaerobic digestion of AAS pretreated manure fibers was tested in CSTR-type digesters fed with swine manure and/or a mixture of swine manure and AAS pretreated manure fibers. The Anaerobic Digestion Model No.1 (ADM1) was used for the prediction of the effect...

  20. Positional Role Differences in the Aerobic and Anaerobic Power of Elite Basketball Players

    Directory of Open Access Journals (Sweden)

    Pojskić Haris

    2015-12-01

    Full Text Available The aim of the present study was to compare the aerobic and anaerobic power and capacity of elite male basketball players who played multiple positions. Fifty-five healthy players were divided into the following three different subsamples according to their positional role: guards (n = 22, forwards (n = 19 and centers (n = 14. The following three tests were applied to estimate their aerobic and anaerobic power and capacities: the countermovement jump (CMJ, a multistage shuttle run test and the Running-based Anaerobic Sprint Test (RAST. The obtained data were used to calculate the players’ aerobic and anaerobic power and capacities. To determine the possible differences between the subjects considering their different positions on the court, one-way analysis of variance (ANOVA with the Bonferroni post-hoc test for multiple comparisons was used. The results showed that there was a significant difference between the different groups of players in eleven out of sixteen measured variables. Guards and forwards exhibited greater aerobic and relative values of anaerobic power, allowing shorter recovery times and the ability to repeat high intensity, basketball-specific activities. Centers presented greater values of absolute anaerobic power and capacities, permitting greater force production during discrete tasks. Coaches can use these data to create more individualized strength and conditioning programs for different positional roles.

  1. Comparison of two different anaerobic feeding strategies to establish a stable aerobic granulated sludge bed.

    Science.gov (United States)

    Rocktäschel, T; Klarmann, C; Helmreich, B; Ochoa, J; Boisson, P; Sørensen, K H; Horn, H

    2013-11-01

    Two different anaerobic feeding strategies were compared to optimize the development and performance of aerobic granules. A stable aerobic granulation of activated sludge was achieved with an anaerobic plug flow operation (PI) and a fast influent step followed by an anaerobic mixing phase (PII). Two lab scale sequencing batch reactors (SBRs) were operated to test the different operation modes. PI with plug flow and a reactor H/D (height/diameter) ratio of 9 achieved a biomass concentration of 20 g(TSS)/L and an effluent TSS concentration of 0.10 g(TSS)/L. PII with the mixed anaerobic phase directly after feeding and a reactor H/D ratio of 2 achieved a biomass concentration of 9 g(TSS)/L and an effluent quality of 0.05 g(TSS)/L. Furthermore, it is shown that the plug flow regime during anaerobic feeding together with the lower H/D ratio of 2 led to channeling effects, which resulted in lower storage of organic carbon and a general destabilization of the granulation process. Compared to the plug flow regime (PI), the anaerobic mixing (PII) provided lower substrate gradients within the biofilm. However, these disadvantages could be compensated by higher mass transfer coefficients in PII (k(L) = 0.3 m/d for PI; k(L) = 86 m/d for PII) during the anaerobic phase. Copyright © 2013 Elsevier Ltd. All rights reserved.

  2. Evaluation of the anaerobic ability of alpine skiing skiers through the slalom simulator

    Directory of Open Access Journals (Sweden)

    Vasilios Giovanis

    2017-10-01

    Full Text Available Purpose: The purpose of the research was the evaluation of efficiency of anaerobic ability (power, anaerobic endurance, anaerobic fatigue and the restitution of the pulse rate of alpine skiing students through the slalom simulator. In addition, the aim of the research was the correlation of the special tests of alpine skiing on dry ground (octagon test and in snow (triangle test and slalom test with the target of determining ability levels. Methods: The 20 people sample was composed by two teams of male and female who took the course for advanced (n = 7 aged 23±1.40 years and for beginners course (n = 13 aged 20±1.49 years. For the evaluation process two special tests were used, on the ground and in snow. The ground test was completed in the slalom simulator for 40 seconds. The second ground test was the octagon bouncing (40cm each side x 3. The snow test was the Haczkiewicz test (triangle test and the slalom (7 gates, where the time of a try was measured. Results: The best efficiency in anaerobic power was made by the advanced males and females, while in the anaerobic endurance by the beginners males and females. The best performance in the dexterity tests in snow on the triangle and slalom test was made by the advanced males and beginners females respectively. Conclusions: The significant correlation between the results of anaerobic performance in the slalom simulator and the triangle test in snow confirms the means of diagnosing skill and fitness on dry ground and snow respectively. There is a significant correlation between snow test results and there is no correlation with the octagon test. The aforementioned results can be used in the talent selection process of alpine skiing.

  3. ANAEROBIC BIODEGRADATION OF A BIODEGRADABLE MATERIAL UNDER ANAEROBIC - THERMOPHILIC DIGESTION

    Directory of Open Access Journals (Sweden)

    RICARDO CAMACHO-MUÑOZ

    2014-12-01

    Full Text Available This paper dertermined the anaerobic biodegradation of a polymer obtained by extrusion process of native cassava starch, polylactic acid and polycaprolactone. Initially a thermophilic - methanogenic inoculum was prepared from urban solid waste. The gas final methane concentration and medium’s pH reached values of 59,6% and 7,89 respectively. The assay assembly was carried out according ASTM D5511 standard. The biodegradation percent of used materials after 15 day of digestion were: 77,49%, 61,27%, 0,31% for cellulose, sample and polyethylene respectively. Due cellulose showed biodegradation levels higher than 70% it’s deduced that the inoculum conditions were appropriate. A biodegradation level of 61,27%, 59,35% of methane concentration in sample’s evolved gas and a medium’s finale pH of 7,71 in sample’s vessels, reveal the extruded polymer´s capacity to be anaerobically degraded under thermophilic- high solid concentration conditions.

  4. The Effect of Sleep Deprivation on Choice Reaction Time and Anaerobic Power of College Student Athletes

    OpenAIRE

    Taheri, Morteza; Arabameri, Elaheh

    2012-01-01

    Purpose The aim of this study was to determine the effect of one night's sleep deprivation on anaerobic performance and Reaction time of subjects in the morning of the following day. Methods Eighteen male college student athletes were studied twice in a balanced, randomized design. Subjects were measured for peak power, mean power and Reaction time. Results The performance showed no significant difference in both tests of anaerobic power (peak power, mean power) over the sleep deprivation per...

  5. Anaerobic Digestion and Biogas Potential: Simulation of Lab and Industrial-Scale Processes

    OpenAIRE

    Ihsan Hamawand; Craig Baillie

    2015-01-01

    In this study, a simulation was carried out using BioWin 3.1 to test the capability of the software to predict the biogas potential for two different anaerobic systems. The two scenarios included: (1) a laboratory-scale batch reactor; and (2) an industrial-scale anaerobic continuous lagoon digester. The measured data related to the operating conditions, the reactor design parameters and the chemical properties of influent wastewater were entered into BioWin. A sensitivity analysis was carried...

  6. Velvet pad surface sampling of anaerobic and aerobic bacteria: an in vitro laboratory model.

    OpenAIRE

    Raahave, D; Friis-Møller, A

    1982-01-01

    Velvet pads have been evaluated in an experimental, laboratory model, simulating intraoperative sampling of Staphylococcus epidermis, Escherichia coli and Bacteroides fragilis. After sampling, the pad was placed in a transport medium and kept in an anaerobic atmosphere, before being shaken and rinsed, followed by anaerobic and aerobic culture. This technique permitted quantitatively high recoveries of the test bacteria. Velvet pad sampling could be a measure to determine the density of aerobi...

  7. Innovative microbial fuel cell for electricity production from anaerobic reactors

    Science.gov (United States)

    Min, Booki; Angelidaki, Irini

    A submersible microbial fuel cell (SMFC) was developed by immersing an anode electrode and a cathode chamber in an anaerobic reactor. Domestic wastewater was used as the medium and the inoculum in the experiments. The SMFC could successfully generate a stable voltage of 0.428 ± 0.003 V with a fixed 470 Ω resistor from acetate. From the polarization test, the maximum power density of 204 mW m -2 was obtained at current density of 595 mA m -2 (external resistance = 180 Ω). The power generation showed a saturation-type relationship as a function of wastewater strength, with a maximum power density (P max) of 218 mW m -2 and a saturation constant (K s) of 244 mg L -1. The main limitations for achieving higher electricity production in the SMFC were identified as the high internal resistance at the electrolyte and the inefficient electron transfer at the cathode electrode. As the current increased, a large portion of voltage drop was caused by the ohmic (electrolyte) resistance of the medium present between two electrodes, although the two electrodes were closely positioned (about 3 cm distance; internal resistance = 35 ± 2 Ω). The open circuit potential (0.393 V vs. a standard hydrogen electrode) of the cathode was much smaller than the theoretical value (0.804 V). Besides, the short circuit potential of the cathode electrode decreased during the power generation in the SMFC. These results demonstrate that the SMFC could successfully generate electricity from wastewater, and has a great potential for electricity production from existing anaerobic reactors or other anaerobic environments such as sediments. The advantage of the SMFC is that no special anaerobic chamber (anode chamber) is needed, as existing anaerobic reactors can be used, where the cathode chamber and anode electrode are immersed.

  8. Potential use of the organic fraction of municipal solid waste in anaerobic co-digestion with wastewater in submerged anaerobic membrane technology.

    Science.gov (United States)

    Moñino, P; Jiménez, E; Barat, R; Aguado, D; Seco, A; Ferrer, J

    2016-10-01

    Food waste was characterized for its potential use as substrate for anaerobic co-digestion in a submerged anaerobic membrane bioreactor pilot plant that treats urban wastewater (WW). 90% of the particles had sizes under 0.5mm after grinding the food waste in a commercial food waste disposer. COD, nitrogen and phosphorus concentrations were 100, 2 and 20 times higher in food waste than their average concentrations in WW, but the relative flow contribution of both streams made COD the only pollutant that increased significantly when both substrates were mixed. As sulphate concentration in food waste was in the same range as WW, co-digestion of both substrates would increase the COD/SO4-S ratio and favour methanogenic activity in anaerobic treatments. The average methane potential of the food waste was 421±15mLCH4g(-1)VS, achieving 73% anaerobic biodegradability. The anaerobic co-digestion of food waste with WW is expected to increase methane production 2.9-fold. The settleable solids tests and the particle size distribution analyses confirmed that both treatment lines of a conventional WWTP (water and sludge lines) would be clearly impacted by the incorporation of food waste into its influent. Anaerobic processes are therefore preferred over their aerobic counterparts due to their ability to valorise the high COD content to produce biogas (a renewable energy) instead of increasing the energetic costs associated with the aeration process for aerobic COD oxidation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Anaerobic exercise - Induced changes in serum mineral ...

    African Journals Online (AJOL)

    Anaerobic exercise, a non 02 – dependent energy metabolism leads to transient metabolic changes, which are corrected gradually by homestatic mechanism. We investigated in eight male subjects, the effects of anaerobic exercise after a day sedentary activity on serum mineral concentration. There was significant ...

  10. Method for anaerobic fermentation and biogas production

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to a method for biomass processing, anaerobic fermentation of the processed biomass, and the production biogas. In particular, the invention relates to a system and method for generating biogas from anaerobic fermentation of processed organic material that comprises...

  11. Anaerobic Infections in Children with Neurological Impairments.

    Science.gov (United States)

    Brook, Itzhak

    1995-01-01

    Children with neurological impairments are prone to develop serious infection with anaerobic bacteria. The most common anaerobic infections are decubitus ulcers; gastrostomy site wound infections; pulmonary infections (aspiration pneumonia, lung abscesses, and tracheitis); and chronic suppurative otitis media. The unique microbiology of each of…

  12. Comparison of Leachate Quality from Aerobic and Anaerobic Municipal Solid Waste Bioreactors

    Science.gov (United States)

    Borglin, S. E.; Hazen, T. C.; Oldenburg, C. M.

    2002-12-01

    Municipal solid waste landfills are becoming a drain on the resources of local municipalities as the requirements for stabilization and containment become increasingly stringent. Current regulations limit the moisture in the landfill to minimize leachate production and lower the potential for release of leachate to the environment. Recent research has shown that addition and recycling of moisture in the waste optimizes the biodegradation of stabilization and also provides a means for leachate treatment. This study compares the characteristics of leachate produced from aerobic and anaerobic laboratory bioreactors, and leachate collected from a full-scale anaerobic bioreactor. The laboratory reactors consisted of 200-liter tanks filled with fresh waste materials with the following conditions: (a) aerobic (air injection with leachate recirculation), (b) anaerobic (leachate recirculation). The leachate from the reactors was monitored for metals, nutrients, organic carbon, and microbiological activity for up to 500 days. Leachate from the aerobic tank had significantly lower concentrations of all potential contaminants, both organic and metal, after only a few weeks of operation. Metals leaching was low throughout the test period for the aerobic tanks, and decreased over time for the anaerobic tanks. Organic carbon as measured by BOD, COD, TOC, and COD were an order of magnitude higher in the leachate from the anaerobic system. Microbiological assessment by lipid analysis, enzyme activity assays, and cell counts showed high biomass and diversity in both the aerobic and anaerobic bioreactors, with higher activity in the anaerobic leachate. Results from the full-scale anaerobic bioreactor were not significantly different from those of the laboratory anaerobic bioreactor. The reduction in noxious odors was a significant advantage of the aerobic system. These results suggest that aerobic management of landfills could reduce or eliminate the need for leachate treatment

  13. Comparação da potência anaeróbia mensurada pelo teste de RAST em diferentes condições de calçado e superfícies Comparison of the anaerobic power measured by the RAST test at different footwear and surfaces conditions

    Directory of Open Access Journals (Sweden)

    Carlos Augusto Kalva-Filho

    2013-04-01

    Full Text Available INTRODUÇÃO: O Running Anaerobic Sprint Test (RAST tem sido considerado um teste válido para avaliação anaeróbia. Entretanto, como a superfície e o calçado podem afetar alguns parâmetros mensurados durante o exercício, isso pode modificar os parâmetros do RAST. OBJETIVO: Comparar as variáveis do RAST mensuradas utilizando chuteiras na grama (RAST CG e tênis na pista (RAST TP. MÉTODOS: Oito jogadores de futebol (da categoria sub-17 participaram do estudo. Os participantes realizaram dois RAST (intervalo > 24 h. O RAST consistiu em seis corridas máximas de 35m com 10s de intervalo passivo entre cada corrida. O tempo de cada esforço foi registrado para determinação da potência pico (PP, potência média (PM e índice de fadiga (IF. Após o sexto esforço, amostras sanguíneas foram coletadas para determinação da lactacidemia ([Lac]. RESULTADOS: Durante o RAST TP, a PP (763,1 ± 87,2 W e PM (621,6 ± 68,1 W foram significativamente superiores às PP e PM mensuradas em RAST CG (PP = 667,3 ± 67,0 W e PM = 555,9 ± 74,7 W, enquanto que as [Lac] observadas em RAST TP (7,3 ± 1,8 mmol.L-1 foram significativamente inferiores às mensuradas em RAST CG (9,9 ± 3,2 mmol.L-1. No entanto, o IF não foi significativamente diferente (RAST TP = 32,5 ± 8,3%; RAST CG = 34,1 ± 6,6%. Significativas correlações foram observadas entre as PM (r = 0,90 e as [Lac] (r = 0,72. CONCLUSÃO: Podemos concluir que as variáveis do RAST são influenciadas pela superfície e calçado utilizados, com valores superiores observados em RAST TP.INTRODUCTION: Running Anaerobic Sprint Test (RAST has been considered a valid test for anaerobic evaluation. However, since the floor surfaces and footwear can affect some outcomes measured during exercise, this also can modify the RAST outcomes. OBJECTIVE: Was to compare the RAST outcomes measured using soccer cleats on grass (RAST SCG and using shoes on the track (RAST ST. METHODS: Eight young male soccer players

  14. Prospects of Anaerobic Digestion Technology in China

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    As the world's largest developing country, China must face the problem of managing municipal solid waste, and the challenge of organic waste disposal is even more serious. Considering the characteristics of traditional waste disposal technologies and the subsequent secondary pollution, anaerobic digestion has various advantages such as reduction in the land needed for disposal and preservation of environmental quality. In light of the energy crisis, this paper focuses on the potential production of biogas from biowaste through anaerobic digestion processes, the problems incurred by the waste collection system, and the efficiency of the anaerobic digestion process. Use of biogas in a combined heat and power cogeneration system is also discussed. Finally, the advantages of anaerobic digestion technology for the Chinese market are summarized. The anaerobic digestion is suggested to be a promising treating technology for the organic wastes in China.

  15. Biotransformation of tetrabromobisphenol A (TBBPA) in anaerobic digester sludge, soils, and freshwater sediments.

    Science.gov (United States)

    McAvoy, Drew C; Pittinger, Charles A; Willis, Alison M

    2016-09-01

    The biotransformation of tetrabromobisphenol A (TBBPA) was evaluated in anaerobic digester sludge, soils, and freshwater sediments. In anaerobic digester sludge, TBBPA biotransformed rapidly with a 50% disappearance time (DT50) of 19 days, though little mineralization (1.1%) was observed. In aerobic soils, mineralization of TBBPA ranged from 17.5% to 21.6% with 55.3-83.6% of the TBBPA incorporated into the soils as a non-extractable bound residue. The DT50 for TBBPA in aerobic soils ranged from 5.3 to 7.7 days. In anaerobic soils, 48.3-100% of the TBBPA was incorporated into the soils as non-extractable bound residue with digester sludge and sediments) by debromination and slowly mineralized in the test environments (anaerobic digester sludge, soils, and freshwater sediments). Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  16. Dynamics of the anaerobic process: Effects of volatile fatty acids

    DEFF Research Database (Denmark)

    Pind, Peter Frode; Angelidaki, Irini; Ahring, Birgitte Kiær

    2003-01-01

    A complex and fast dynamic response of the anaerobic biogas system was observed when the system was subjected to pulses of volatile fatty acids (VFAs). It was shown that a pulse of specific VFAs into a well-functioning continuous stirred tank reactor (CSTR) system operating on cow manure affected...... or inhibition was shown for the degradation of all VFAs tested. Based on the results, it was concluded that measurements of all specific VFAs are important for control purposes and increase and decrease in a specific VFA should always be evaluated in close relationship to the conversion of other VFAs...... and the history of the reactor process. It should be pointed out that the observed dynamics of VFA responses were based on hourly measurements, meaning that the response duration was much lower than the hydraulic retention time, which exceeds several days in anaerobic CSTR systems....

  17. Cosmetic wastewater treatment by upflow anaerobic sludge blanket reactor

    Energy Technology Data Exchange (ETDEWEB)

    Puyol, D.; Monsalvo, V.M.; Mohedano, A.F. [Seccion de Ingenieria Quimica, Facultad de Ciencias, Universidad Autonoma de Madrid, C/ Francisco Tomas y Valiente 7, 28049, Madrid (Spain); Sanz, J.L. [Departamento de Biologia Molecular, Facultad de Ciencias, Universidad Autonoma de Madrid, C/ Francisco Tomas y Valiente 7, 28049, Madrid (Spain); Rodriguez, J.J., E-mail: juanjo.rodriguez@uam.es [Seccion de Ingenieria Quimica, Facultad de Ciencias, Universidad Autonoma de Madrid, C/ Francisco Tomas y Valiente 7, 28049, Madrid (Spain)

    2011-01-30

    Anaerobic treatment of pre-settled cosmetic wastewater in batch and continuous experiments has been investigated. Biodegradability tests showed high COD and solid removal efficiencies (about 70%), being the hydrolysis of solids the limiting step of the process. Continuous treatment was carried out in an upflow anaerobic sludge blanket reactor. High COD and TSS removal efficiencies (up to 95% and 85%, respectively) were achieved over a wide range of organic load rate (from 1.8 to 9.2 g TCOD L{sup -1} day{sup -1}). Methanogenesis inhibition was observed in batch assays, which can be predicted by means of a Haldane-based inhibition model. Both COD and solid removal were modelled by Monod and pseudo-first order models, respectively.

  18. Anaerobic exercise and oxidative stress: a review.

    Science.gov (United States)

    Bloomer, Richard J; Goldfarb, Allen H

    2004-06-01

    Oxidative stress and subsequent damage to cellular proteins, lipids, and nucleic acids, as well as changes to the glutathione system, are well documented in response to aerobic exercise. However, far less information is available on anaerobic exercise-induced oxidative modifications. Recent evidence indicates that high intensity anaerobic work does result in oxidative modification to the above-mentioned macromolecules in both skeletal muscle and blood. Also, it appears that chronic anaerobic exercise training can induce adaptations that act to attenuate the exercise-induced oxidative stress. These may be specific to increased antioxidant defenses and/or may act to reduce the generation of pro-oxidants during and after exercise. However, a wide variety of exercise protocols and assay procedures have been used to study oxidative stress pertaining to anaerobic work. Therefore, precise conclusions about the exact extent and location of oxidative macromolecule damage, in addition to the adaptations resulting from chronic anaerobic exercise training, are difficult to indicate. This manuscript provides a review of anaerobic exercise and oxidative stress, presenting both the acute effects of a single exercise bout and the potential for adaptations resulting from chronic anaerobic training.

  19. Anaerobic degradation of linear alkylbenzene sulfonate

    DEFF Research Database (Denmark)

    Mogensen, Anders Skibsted; Haagensen, Frank; Ahring, Birgitte Kiær

    2003-01-01

    Linear alkylbenzene sulfonate (LAS) found in wastewater is removed in the wastewater treatment facilities by sorption and aerobic biodegradation. The anaerobic digestion of sewage sludge has not been shown to contribute to the removal. The concentration of LAS based on dry matter typically...... increases during anaerobic stabilization due to transformation of easily degradable organic matter. Hence, LAS is regarded as resistant to biodegradation under anaerobic conditions. We present data from a lab-scale semi-continuously stirred tank reactor (CSTR) spiked with linear dodecylbenzene sulfonate (C...

  20. Molecular ecology of anaerobic reactor systems

    DEFF Research Database (Denmark)

    Hofman-Bang, H. Jacob Peider; Zheng, D.; Westermann, Peter

    2003-01-01

    to the abundance of each microbe in anaerobic reactor systems by rRNA probing. This chapter focuses on various molecular techniques employed and problems encountered when elucidating the microbial ecology of anaerobic reactor systems. Methods such as quantitative dot blot/fluorescence in-situ probing using various...... and malfunctions of anaerobic digesters occasionally experienced, leading to sub-optimal methane production and wastewater treatment. Using a variety of molecular techniques, we are able to determine which microorganisms are active, where they are active, and when they are active, but we still need to determine...

  1. Determining the anaerobic threshold in post-polio syndrome: comparison with current guidelines for training intensity prescription.

    NARCIS (Netherlands)

    Voorn, E.L.; Gerrits, K.H.L.; Koopman, F.S.; Nollet, F.; Beelen, A.

    2014-01-01

    Objectives To determine whether the anaerobic threshold (AT) can be identified in individuals with postpolio syndrome (PPS) using submaximal incremental exercise testing, and to compare current guidelines for intensity prescription in PPS with the AT. Design Cohort study. Setting Research

  2. Stress hormone epinephrine (adrenaline) and norepinephrine (noradrenaline) effects on the anaerobic bacteria.

    Science.gov (United States)

    Boyanova, Lyudmila

    2017-04-01

    Microbial endocrinology is a relatively new research area that already encompasses the anaerobes. Stress hormones, epinephrine and norepinephrine, can affect the growth of anaerobic bacteria such as Fusobacterium nucleatum, Prevotella spp., Porhyromonas spp., Tanerella forsythia and Propionibacterium acnes and can increase virulence gene expression, iron acquisition and many virulence factors of some anaerobic species such as Clostridium perfringens, Porphyromonas gingivalis and Brachyspira pilosicoli. Epinephrine and norepinephrine effects can lead to a growth increase or decrease, or no effect on the growth of the anaerobes. The effects are species-specific and perhaps strain-specific. Discrepancies in the results of some studies can be due to the different methods and media used, catecholamine concentrations, measurement techniques and the low number of strains tested. Biological effects of the stress hormones on the anaerobes may range from halitosis and a worsening of periodontal diseases to tissue damages and atherosclerotic plaque ruptures. Optimizations of the research methods and a detailed assessment of the catecholamine effects in conditions mimicking those in affected organs and tissues, as well as the effects on the quorum sensing and virulence of the anaerobes and the full spectrum of biological consequences of the effects are interesting topics for further evaluation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Growth of Chlorella vulgaris on sugarcane vinasse: the effect of anaerobic digestion pretreatment.

    Science.gov (United States)

    Marques, Sheyla Santa Isabel; Nascimento, Iracema Andrade; de Almeida, Paulo Fernando; Chinalia, Fábio Alexandre

    2013-12-01

    Microalgae farming has been identified as the most eco-sustainable solution for producing biodiesel. However, the operation of full-scale plants is still limited by costs and the utilization of industrial and/or domestic wastes can significantly improve economic profits. Several waste effluents are valuable sources of nutrients for the cultivation of microalgae. Ethanol production from sugarcane, for instance, generates significant amounts of organically rich effluent, the vinasse. After anaerobic digestion treatment, nutrient remaining in such an effluent can be used to grow microalgae. This research aimed to testing the potential of the anaerobic treated vinasse as an alternative source of nutrients for culturing microalgae with the goal of supplying the biodiesel industrial chain with algal biomass and oil. The anaerobic process treating vinasse reached a steady state at about 17 batch cycles of 24 h producing about 0.116 m(3)CH4 kgCODvinasse (-1). The highest productivity of Chlorella vulgaris biomass (70 mg l(-1) day(-1)) was observed when using medium prepared with the anaerobic digester effluent. Lipid productivity varied from 0.5 to 17 mg l(-1) day(-1). Thus, the results show that it is possible to integrate the culturing of microalgae with the sugarcane industry by means of anaerobic digestion of the vinasse. There is also the advantageous possibility of using by-products of the anaerobic digestion such as methane and CO2 for sustaining the system with energy and carbon source, respectively.

  4. Relationships among traits of aerobic and anaerobic swimming performance in individual European sea bass Dicentrarchus labrax.

    Directory of Open Access Journals (Sweden)

    Stefano Marras

    Full Text Available Teleost fishes exhibit wide and temporally stable inter-individual variation in a suite of aerobic and anaerobic locomotor traits. One mechanism that could allow such variation to persist within populations is the presence of tradeoffs between aerobic and anaerobic performance, such that individuals with a high capacity for one type of performance have a reduced capacity for the other. We investigated this possibility in European seabass Dicentrarchuslabrax, each measured for a battery of indicators of maximum locomotor performance. Aerobic traits comprised active metabolic rate, aerobic scope for activity, maximum aerobic swimming speed, and stride length, using a constant acceleration test. Anaerobic traits comprised maximum speed during an escape response, maximum sprint speed, and maximum anaerobic burst speed during constant acceleration. The data provided evidence of significant variation in performance among individuals, but there was no evidence of any trade-offs among any traits of aerobic versus anaerobic swimming performance. Furthermore, the anaerobic traits were not correlated significantly among each other, despite relying on the same muscular structures. Thus, the variation observed may reflect trade-offs with other morphological, physiological or behavioural traits.

  5. Anaerobe Tolerance to Oxygen and the Potentials of Anaerobic and Aerobic Cocultures for Wastewater Treatment

    Directory of Open Access Journals (Sweden)

    M.T. Kato

    1997-12-01

    Full Text Available The anaerobic treatment processes are considered to be well-established methods for the elimination of easily biodegradable organic matter from wastewaters. Some difficulties concerning certain wastewaters are related to the possible presence of dissolved oxygen. The common belief is that anaerobes are oxygen intolerant. Therefore, the common practice is to use sequencing anaerobic and aerobic steps in separate tanks. Enhanced treatment by polishing off the residual biodegradable oxygen demand from effluents of anaerobic reactors, or the biodegradation of recalcitrant wastewater pollutants, usually requires sequenced anaerobic and aerobic bacteria activities. However, the combined activity of both bacteria can also be obtained in a single reactor. Previous experiments with either pure or mixed cultures showed that anaerobes can tolerate oxygen to a certain extent. The oxygen toxicity to methanogens in anaerobic sludges was quantified in batch experiments, as well as in anaerobic reactors. The results showed that methanogens have a high tolerance to oxygen. In practice, it was confirmed that dissolved oxygen does not constitute any detrimental effect on reactor treatment performance. This means that the coexistence of anaerobic and aerobic bacteria in one single reactor is feasible and increases the potentials of new applications in wastewater treatment

  6. The alteration of NTproCNP plasma levels following anaerobic exercise in physically active young men.

    Science.gov (United States)

    Akseki Temür, Hilal; Vardar, Selma Arzu; Demir, Muzaffer; Palabıyık, Orkide; Karaca, Aziz; Guksu, Zuhal; Ortanca, Arif; Süt, Necdet

    2015-02-01

    Amino-terminal propeptide of C-type natriuretic peptide (NTproCNP) is a synthesis product of C-type natriuretic peptide (CNP). In this study, plasma levels of NTproCNP were compared before and after exercise in healthy young subjects who are physically active (PA) or not physically active (NPA). The study was carried on PA group (n=10) who defined the exercise duration more than 2.5 hours per week for at least one year and NPA group (n = 10) whose exercise duration was lower than 1.5 hours per week. The level of maximal oxygen consumption was determined. Wingate exercise test was applied on the following day. Plasma NTproCNP levels were measured before the exercise and at the 1st, 5th and 30th minute after the exercise. Exercise duration of physically active group was reported as 11.3 ± 5.0 hours per week. Basal NTproCNP levels of the groups were found to be comparable. NTproCNP levels in the 5th minute (0.93 ± 0.23 pmol/L; pexercise were higher than the levels before exercise (0.64 ± 0.29 pmol/L) in PA group. Additionally, the plasma levels of NTproCNP after 5th minute of exercise were higher in PA group (0.93 ± 0.23 pmol/L) than NPA group (0.74 ± 0.16 pmol/L, pexercise.

  7. The Energetics of Aerobic versus Anaerobic Respiration.

    Science.gov (United States)

    Champion, Timothy D.; Schwenz, Richard W.

    1990-01-01

    Background information, laboratory procedures, and a discussion of the results of an experiment designed to investigate the difference in energy gained from the aerobic and anaerobic oxidation of glucose are presented. Sample experimental and calculated data are included. (CW)

  8. An anaerobic mitochondrion that produces hydrogen

    NARCIS (Netherlands)

    Boxma, Brigitte; Graaf, Rob M. de; Staay, Georg W.M. van der; Alen, Theo A. van; Ricard, Guenola; Gabaldón, Toni; Hoek, Angela H.A.M. van; Moon-van der Staay, Seung Yeo; Koopman, Werner J.H.; Hellemond, Jaap J. van; Tielens, Aloysius G.M.; Friedrich, Thorsten; Veenhuis, Marten; Huynen, Martijn A.; Hackstein, Johannes H.P.

    2005-01-01

    Hydrogenosomes are organelles that produce ATP and hydrogen, and are found in various unrelated eukaryotes, such as anaerobic flagellates, chytridiomycete fungi and ciliates. Although all of these organelles generate hydrogen, the hydrogenosomes from these organisms are structurally and

  9. Exocellular electron transfer in anaerobic microbial communities

    NARCIS (Netherlands)

    Stams, A.J.M.; Bok, de F.A.M.; Plugge, C.M.; Eekert, van M.H.A.; Dolfing, J.; Schraa, G.

    2006-01-01

    Exocellular electron transfer plays an important role in anaerobic microbial communities that degrade organic matter. Interspecies hydrogen transfer between microorganisms is the driving force for complete biodegradation in methanogenic environments. Many organic compounds are degraded by obligatory

  10. Anaerobic Toxicity of Cationic Silver Nanoparticles

    Data.gov (United States)

    U.S. Environmental Protection Agency — Toxicity data for the impact of nano-silver on anaerobic degradation. This dataset is associated with the following publication: Gitipour, A., S. Thiel, K. Scheckel,...

  11. An anaerobic mitochondrion that produces hydrogen

    NARCIS (Netherlands)

    Boxma, B.; Graaf, de R.M.; Staay, van der G.W.M.; Alen, T.A.; Richard, G.; Gabalon, T.; Hoek, van A.H.A.M.; Moon - van der Staay, S.Y.; Koopman, W.J.H.; Hellemond, van J.J.; Tielens, A.G.M.; Friedrich, T.; Veenhuis, M.; Huynen, M.A.; Hackstein, J.H.P.

    2005-01-01

    Hydrogenosomes are organelles that produce ATP and hydrogen(1), and are found in various unrelated eukaryotes, such as anaerobic flagellates, chytridiomycete fungi and ciliates(2). Although all of these organelles generate hydrogen, the hydrogenosomes from these organisms are structurally and

  12. [Agroindustrial wastes methanization and bacterial composition in anaerobic digestion].

    Science.gov (United States)

    González-Sánchez, María E; Pérez-Fabiel, Sergio; Wong-Villarreal, Arnoldo; Bello-Mendoza, Ricardo; Yañez-Ocampo, Gustavo

    2015-01-01

    The tons of organic waste that are annually generated by agro-industry, can be used as raw material for methane production. For this reason, it is important to previously perform biodegradability tests to organic wastes for their full scale methanization. This paper addresses biodegradability, methane production and the behavior of populations of eubacteria and archaeabacteria during anaerobic digestion of banana, mango and papaya agroindustrial wastes. Mango and banana wastes had higher organic matter content than papaya in terms of their volatile solids and total solid rate (94 and 75% respectively). After 63 days of treatment, the highest methane production was observed in banana waste anaerobic digestion: 63.89ml CH4/per gram of chemical oxygen demand of the waste. In the PCR-DGGE molecular analysis, different genomic footprints with oligonucleotides for eubacteria and archeobacteria were found. Biochemical methane potential results proved that banana wastes have the best potential to be used as raw material for methane production. The result of a PCR- DGGE analysis using specific oligonucleotides enabled to identify the behavior of populations of eubacteria and archaeabacteria present during the anaerobic digestion of agroindustrial wastes throughout the process. Copyright © 2015 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  13. Multi-wavelength fluorometry for anaerobic digestion process monitoring.

    Science.gov (United States)

    Morel, E; Santamaria, K; Perrier, M; Guiot, S R; Tartakovsky, B

    2005-01-01

    Applicability of multi-wavelength fluorometry for anaerobic digestion process monitoring was investigated in a 3.5 L upflow anaerobic sludge bed (UASB) lab-scale reactor. Both off-line and on-line monitoring of key process parameters was tested. Off-line emission spectra were measured at an angle of 90 degrees to the excitation beam using a cuvette. On-line measurements were carried out using a fiber optic probe in the external recirculation line of the digester. Fluorescence spectra were correlated to available analytical measurements to obtain partial least square regression models. An independent set of measurements was used to validate the regression models. Model estimations showed reasonable agreement with analytical measurements with multiple determination coefficients (R2) between 0.6 and 0.95. Results showed that offline fluorescence measurements can be used for fast estimation of anaerobic digestor effluent quality. At the same time, the on-line implementation of multi-wavelength fluorescence measurements can be used for realtime process monitoring and, potentially, for on-line process control.

  14. EFFECT OF MUSIC ON ANAEROBIC EXERCISE PERFORMANCE

    OpenAIRE

    Tülin Atan

    2013-01-01

    For years, mostly the effects of music on cardiorespiratory exercise performance have been studied, but a few studies have examined the effect of music on anaerobic exercise. The purpose of this study was to assess the effect of listening to music and its rhythm on anaerobic exercise: on power output, heart rate and the concentration of blood lactate. 28 male subjects were required to visit the laboratory on 6 occasions, each separated by 48 hours. Firstly, each subject performed the Running-...

  15. Maximizing biogas production from the anaerobic digestion

    OpenAIRE

    Ghouali, A.; Sari, T.; Harmand, J.

    2015-01-01

    This paper presents an optimal control law policy for maximizing biogas production of anaerobic digesters. In particular, using a simple model of the anaerobic digestion process, we derive a control law to maximize the biogas production over a period T using the dilution rate as the control variable. Depending on initial conditions and constraints on the actuator (the dilution rate D(·)), the search for a solution to the optimal control problem reveals very different levels of difficulty. In ...

  16. Anaerobic digester for treatment of organic waste

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, V. K. [Indian Insitute of Technology, Delhi (India)]|[ENEA, Centro Ricerche Trisaia, Matera (Italy); Fortuna, F.; Canditelli, M.; Cornacchia, G. [ENEA, Centro Ricerche Trisaia, Matera (Italy). Dipt. Ambiente; Farina, R. [ENEA, centro Ricerche ``Ezio Clementel``, Bologna (Italy). Dipt. Ambiente

    1997-09-01

    The essential features of both new and more efficient reactor systems and their appropriate applications for various organic waste management situations, description of several working plants are discussed in the present communication. It is hoped that significant development reported here would be useful in opening a new vista to the application of anaerobic biotechnology for the waste treatment of both low/high organic strength and specialized treatment for toxic substances, using appropriate anaerobic methods.

  17. Anaerobic Digestion Performance in the Energy Recovery of Kiwi Residues

    Science.gov (United States)

    Martins, Ramiro; Boaventura, Rui; Paulista, Larissa

    2017-12-01

    World production and trade of fruits generate losses in the harvest, post-harvest, handling, distribution and consumption phases, corresponding to 6.8% of total production. These residues present high potential as a substrate for the anaerobic digestion process and biogas generation. Thus, the energy valuation of the agro-industrial residues of kiwi production was evaluated by anaerobic digestion, aiming at optimizing the biogas production and its quality. Ten assays were carried out in a batch reactor (500 mL) under mesophilic conditions and varying a number of operational factors: different substrate/inoculum ratios; four distinct values for C: N ratio; inoculum from different digesters; and inoculum collected at different times of the year. The following parameters were used to control and monitor the process: pH, alkalinity, volatile fatty acids (VFA), volatile solids (VS) and chemical oxygen demand (COD). Among the tests performed, the best result obtained for the biogas production corresponded to the use of 2 g of substrate and 98 mL of inoculum of the anaerobic digester of the Wastewater Treatment Plant (WWTP) of Bragança, with addition of 150 mg of bicarbonate leading to a production of 1628 L biogas.kg-1 VS (57% methane). In relation to the biogas quality, the best result was obtained with 20 g of substrate and 380 mL of inoculum from the anaerobic digester sludge of WWTP of Ave (with addition 600 mg of sodium bicarbonate), presenting a value of 85% of CH4, with a production of 464 L biogas.kg-1 VS.

  18. Hydrogen generation via anaerobic fermentation of paper mill wastes.

    Science.gov (United States)

    Valdez-Vazquez, Idania; Sparling, Richard; Risbey, Derek; Rinderknecht-Seijas, Noemi; Poggi-Varaldo, Héctor M

    2005-11-01

    The objective of this work was to determine the hydrogen production from paper mill wastes using microbial consortia of solid substrate anaerobic digesters. Inocula from mesophilic, continuous solid substrate anaerobic digestion (SSAD) reactors were transferred to small lab scale, batch reactors. Milled paper (used as a surrogate paper waste) was added as substrate and acetylene or 2-bromoethanesulfonate (BES) was spiked for methanogenesis inhibition. In the first phase of experiments it was found that acetylene at 1% v/v in the headspace was as effective as BES in inhibiting methanogenic activity. Hydrogen gas accumulated in the headspace of the bottles, reaching a plateau. Similar final hydrogen concentrations were obtained for reactors spiked with acetylene and BES. In the second phase of tests the headspace of the batch reactors was flushed with nitrogen gas after the first plateau of hydrogen was reached, and subsequently incubated, with no further addition of inhibitor nor substrate. It was found that hydrogen production resumed and reached a second plateau, although somewhat lower than the first one. This procedure was repeated a third time and an additional amount of hydrogen was obtained. The plateaux and initial rates of hydrogen accumulation decreased in each subsequent incubation cycle. The total cumulative hydrogen harvested in the three cycles was much higher (approx. double) than in the first cycle alone. We coined this procedure as IV-SSAH (intermittently vented solid substrate anaerobic hydrogen generation). Our results point out to a feasible strategy for obtaining higher hydrogen yields from the fermentation of industrial solid wastes, and a possible combination of waste treatment processes consisting of a first stage IV-SSAH followed by a second SSAD stage. Useful products of this approach would be hydrogen, organic acids or methane, and anaerobic digestates that could be used as soil amenders after post-treatment.

  19. Solubilization of activated sludge by isolated acid-forming anaerobes. Shizenkai yori bunrishita sanseiseikin no yoru yojo kassei odei no kayoka bunkai

    Energy Technology Data Exchange (ETDEWEB)

    Kitazume, M. (Fujita, Co. Ltd., Yokohama (Japan)); Ueyama, S. (Yakult Co. Ltd., Tokyo (Japan)); Benno, Y. (The Institute of Physical and Chemical Research, Saitama (Japan))

    1991-09-25

    In order to improve the efficiency in anaerobic digestion of activated sludge, effective solubilization of activated sludge by using acid-forming anaerobes was studied. To this end, investigation and screening of such anaerobes from nature were tried. As a result, seven strains of high acid-forming anaerobes were isolated and identified. The isolates strains solubilized volatile solids in activated sludge more than 50 %, and converted most of the solubilized part to volatile fatty acids, principally acetic acid. The strains were inoculated and the digestion was tested in bench-scaled batch fermenters. These isolated anaerobes contributed to accelerating the initial degestion rate more than 20 % and increasing methane production more than 10% in batch culture running for 30 days. It was concluded that the isolated strains were effective to improve the efficiency in anaerobic digestion by accelerating solubilization of sludge, accompanied with formation of volatile fatty acid especially acetic acid. 13 refs., 1 fig., 7 tabs.

  20. The Relationship Between Endurance Of Periscapular Muscles, Anaerobic Performance And Agility In Professional Athletes

    Science.gov (United States)

    Zorlular, Ali; Çobanoğlu, Gamze; Keklik, Sinem Suner; Gökdoğan, Çağatay Müslim; Akaras, Esedullah; Polat, Elif Aygün; Kafa, Nihan; Güzel, Nevin Atalay

    2017-01-01

    Objective: The purpose of this study was to identify relationships between endurance of periscapular muscle, anaerobic performance and agility in professional athletes. Methods: 70 professional basketball, volleyball, and handball players (male: 25 female: 45 age 20.41±5.72, BMI: 21.70±2.51) were included to this study. Anaerobic performance was assessed with vertical jump test. Periscapular muscles endurance was evaluated using scapular muscle endurance test and agility was measured hexagonal obstacle test. Statistical analysis was performed using the statistical software SPSS 22. Results: Spearman correlation analysis results showed that there was positive significant correlation between anaerobic performance and endurance of periscapular muscles (pagility (pagility and endurance of periscapular muscles (pagility performance in sports.

  1. Anaerobic digestion of slaughterhouse by-products

    Energy Technology Data Exchange (ETDEWEB)

    Hejnfelt, Anette; Angelidaki, Irini [Department of Environmental Engineering, Technical University of Denmark, DTU, Building 113, DK-2800 Kgs. Lyngby (Denmark)

    2009-08-15

    Anaerobic digestion of animal by-products was investigated in batch and semi-continuously fed, reactor experiments at 55 C and for some experiments also at 37 C. Separate or mixed by-products from pigs were tested. The methane potential measured by batch assays for meat- and bone flour, fat, blood, hair, meat, ribs, raw waste were: 225, 497, 487, 561, 582, 575, 359, 619 dm{sup 3} kg{sup -1} respectively, corresponding to 50-100% of the calculated theoretical methane potential. Dilution of the by-products had a positive effect on the specific methane yield with the highest dilutions giving the best results. High concentrations of long-chain fatty acids and ammonia in the by-products were found to inhibit the biogas process at concentrations higher than 5 g lipids dm{sup -3} and 7 g N dm{sup -3} respectively. Pretreatment (pasteurization: 70 C, sterilization: 133 C), and alkali hydrolysis (NaOH) had no effect on achieved methane yields. Mesophilic digestion was more stable than thermophilic digestion, and higher methane yield was noticed at high waste concentrations. The lower yield at thermophilic temperature and high waste concentration was due to ammonia inhibition. Co-digestion of 5% pork by-products mixed with pig manure at 37 C showed 40% higher methane production compared to digestion of manure alone. (author)

  2. Anaerobic sludge digestion with a biocatalytic additive

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, S.; Henry, M.P.; Fedde, P.A.

    1982-01-01

    The objective of this research was to evaluate the effects of a lactobacillus additive an anaerobic sludge digestion under normal, variable, and overload operating conditions. The additive was a whey fermentation product of an acid-tolerant strain of Lactobacillus acidophilus fortified with CaCO/sub 3/, (NH/sub 4/)/sub 2/HPO/sub 4/, ferrous lactate, and lactic acid. The lactobacillus additive is multifunctional in nature and provides growth factors, metabolic intermediates, and enzymes needed for substrate degradation and cellular synthesis. The experimental work consisted of several pairs of parallel mesophilic (35/sup 0/C) digestion runs (control and test) conducted in five experimental phases. Baseline runs without the additive showed that the two experimental digesters had the same methane content, gas production rate (GPR), and ethane yield. The effect of the additive was to increase methane yield and GPR by about 5% (which was statistically significant) during digester operation at a loading rate (LR) of 3.2 kg VS/m/sup 3/-day and a hydraulic retention time (HRT) of 14 days. Data collected from the various experimental phases showed that the biochemical additive increased methane yield, gas production rate, and VS reduction, and decreased volatile acids accumulation. In addition, it enhanced digester buffer capacity and improved the fertilizer value and dewatering characteristics of the digested residue.

  3. Profile of anaerobic bacteriology of middle ear aspirates in a developing country: does immunocompromise play a role?

    Science.gov (United States)

    Adebola, Stephen Oluwatosin; Ologe, Foluwasayo Emmanuel; Alabi, Biodun Sulyman; Nwabuisi, Charles; Fowotade, Adeola

    2014-04-01

    The study intends to report the profiles of anaerobic bacteria isolated and attempts to evaluate the impact of immunocompromised status of patients on the disease. A cross-sectional prospective study. ENT clinic, University of Ilorin Teaching Hospital, Nigeria; a 450-bed tertiary health facility. 104 consecutive consenting participants with clinical evidence of CSOM ≥12 weeks. A hospital-based study conducted over a seven (7) month period. The middle ear aspirate was obtained with the aid of a micropipette and sent immediately for Microscopy, Culture and Sensitivity of both anaerobic and aerobic bacterial isolates. A total of 11 patients with chronically discharging ears, of the 104 studied had anaerobic bacteria cultured from their middle ear aspirates. Age ranged from 4 to 50 years with a male:female ratio of 1:1.8. A total of 32 isolates (11 anaerobic and 21 aerobic) were recovered. All anaerobic organisms were mixed and included both Peptostreptococcus and Bacteroides. Metronidazole had 100% sensitivity to gram negative and 62.5% to gram positive anaerobic organisms tested. Five (5) patients had immunocompromised states of 11 patients with anaerobic bacteria isolated in middle ear aspirates (group I), while 13 immunocompromised patients of the remaining 93 patients with no anaerobic bacteria isolated (group II). The proportion of anaerobic isolates in group I is higher (p < 0.05) than in group II. Immunocompromised state and age appear to play key role in presence of the anaerobic organisms recovered from the middle ear of the patients studied. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Effect of sex and menstrual cycle in women on starting speed, anaerobic endurance and muscle power.

    Science.gov (United States)

    Wiecek, M; Szymura, J; Maciejczyk, M; Cempla, J; Szygula, Z

    2016-03-01

    The aim of our study was to compare the indicators of starting speed, anaerobic endurance and power in women as well as men, and to investigate whether the values of these indicators differ in women during the follicular and luteal phases of the menstrual cycle. The studied group included 16 men and 16 women. The subjects performed the 20-second maximal cycling sprint test. The men performed the test twice at 14-day intervals. The women undertook the test 4 times: twice during the middle of follicular phase and twice in the middle of luteal phase in separate menstrual cycles. Hormonal changes during the menstrual cycle do not influence anaerobic performance, starting speed or anaerobic endurance in women. Anaerobic performance in men is higher than in women with similar aerobic performance expressed as VO2max/LBM (lean body mass). A lower power decrease with time was noted for women than men, with a similar time of maintaining power in both groups. This is evidence of women's better anaerobic endurance compared to men. At the same time, the men had significantly better starting speed rates than women.

  5. Potential for using thermophilic anaerobic bacteria for bioethanol production from hemicellulose

    DEFF Research Database (Denmark)

    Sommer, P.; Georgieva, Tania I.; Ahring, Birgitte Kiær

    2004-01-01

    anaerobic bacterial strains growing optimally at 70-80degreesC for their ethanol production from D-Xylose. The new isolates came from different natural and man-made systems such as hot springs, paper pulp mills and brewery waste water. The test was composed of three different steps; (i) test for conversion...

  6. Anaerobic and aerobic performances in elite basketball players.

    Science.gov (United States)

    de Araujo, Gustavo Gomes; de Barros Manchado-Gobatto, Fúlvia; Papoti, Marcelo; Camargo, Bruno Henrique Ferreira; Gobatto, Claudio Alexandre

    2014-09-29

    THE PURPOSE OF THIS STUDY WAS TO PROPOSE A SPECIFIC LACTATE MINIMUM TEST FOR ELITE BASKETBALL PLAYERS CONSIDERING THE: Running Anaerobic Sprint Test (RAST) as a hyperlactatemia inductor, short distances (specific distance, 20 m) during progressive intensity and mathematical analysis to interpret aerobic and anaerobic variables. The basketball players were assigned to four groups: All positions (n=26), Guard (n= 7), Forward (n=11) and Center (n=8). The hyperlactatemia elevation (RAST) method consisted of 6 maximum sprints over 35 m separated by 10 s of recovery. The progressive phase of the lactate minimum test consisted of 5 stages controlled by an electronic metronome (8.0, 9.0, 10.0, 11.0 and 12.0 km/h) over a 20 m distance. The RAST variables and the lactate values were analyzed using visual and mathematical models. The intensity of the lactate minimum test, determined by a visual method, reduced in relation to polynomial fits (2nd degree) for the Small Forward positions and General groups. The Power and Fatigue Index values, determined by both methods, visual and 3rd degree polynomial, were not significantly different between the groups. In conclusion, the RAST is an excellent hyperlactatemia inductor and the progressive intensity of lactate minimum test using short distances (20 m) can be specifically used to evaluate the aerobic capacity of basketball players. In addition, no differences were observed between the visual and polynomial methods for RAST variables, but lactate minimum intensity was influenced by the method of analysis.

  7. Perancangan Ulang Instalasi Pengolahan Air Limbah Domestik dengan Proses Anaerobic Baffled Reactor dan Anaerobic Filter

    OpenAIRE

    Habib Prasetia Adi; Mohammad Razif; Atiek Moesriati

    2017-01-01

    Instalasi Pengolahan Air Limbah (IPAL) Tarbiyatul Fallah merupakan IPAL domestik yang melayani Pesantren Tarbiyatul Fallah, namun berhenti beroperasi sejak tahun 2014. Agar manfaat IPAL dapat terus dirasakan, dilakukan perancangan ulang IPAL dengan alternatif Anaerobic Baffled Reactor (ABR) dan Anaerobic Filter (AF). Alternatif IPAL anaerobik yang keunggulan dalam kemudahan penerapan dan biaya operasional yang rendah. Perancangan ulang dimulai dengan mengevaluasi kinerja IPAL yang sudah ada. ...

  8. Anaerobic energy metabolism in unicellular photosynthetic eukaryotes.

    Science.gov (United States)

    Atteia, Ariane; van Lis, Robert; Tielens, Aloysius G M; Martin, William F

    2013-02-01

    Anaerobic metabolic pathways allow unicellular organisms to tolerate or colonize anoxic environments. Over the past ten years, genome sequencing projects have brought a new light on the extent of anaerobic metabolism in eukaryotes. A surprising development has been that free-living unicellular algae capable of photoautotrophic lifestyle are, in terms of their enzymatic repertoire, among the best equipped eukaryotes known when it comes to anaerobic energy metabolism. Some of these algae are marine organisms, common in the oceans, others are more typically soil inhabitants. All these species are important from the ecological (O(2)/CO(2) budget), biotechnological, and evolutionary perspectives. In the unicellular algae surveyed here, mixed-acid type fermentations are widespread while anaerobic respiration, which is more typical of eukaryotic heterotrophs, appears to be rare. The presence of a core anaerobic metabolism among the algae provides insights into its evolutionary origin, which traces to the eukaryote common ancestor. The predicted fermentative enzymes often exhibit an amino acid extension at the N-terminus, suggesting that these proteins might be compartmentalized in the cell, likely in the chloroplast or the mitochondrion. The green algae Chlamydomonas reinhardtii and Chlorella NC64 have the most extended set of fermentative enzymes reported so far. Among the eukaryotes with secondary plastids, the diatom Thalassiosira pseudonana has the most pronounced anaerobic capabilities as yet. From the standpoints of genomic, transcriptomic, and biochemical studies, anaerobic energy metabolism in C. reinhardtii remains the best characterized among photosynthetic protists. This article is part of a Special Issue entitled: The evolutionary aspects of bioenergetic systems. Copyright © 2012 Elsevier B.V. All rights reserved.

  9. Anaerobic digestion of slaughterhouse waste: main process limitations and microbial community interactions.

    Science.gov (United States)

    Palatsi, J; Viñas, M; Guivernau, M; Fernandez, B; Flotats, X

    2011-02-01

    Fresh pig/cattle slaughterhouse waste mixtures, with different lipid-protein ratios, were characterized and their anaerobic biodegradability assessed in batch tests. The resultant methane potentials were high (270-300 L(CH4) kg(-1)(COD)) making them interesting substrates for the anaerobic digestion process. However, when increasing substrate concentrations in consecutive batch tests, up to 15 g(COD) kg(-1), a clear inhibitory process was monitored. Despite the reported severe inhibition, related to lipid content, the system was able to recover activity and successfully degrade the substrate. Furthermore, 16SrRNA gene-based DGGE results showed an enrichment of specialized microbial populations, such as β-oxidizing/proteolitic bacteria (Syntrophomonas sp., Coprothermobacter sp. and Anaerobaculum sp.), and syntrophic methanogens (Methanosarcina sp.). Consequently, the lipid concentration of substrate and the structure of the microbial community are the main limiting factors for a successful anaerobic treatment of fresh slaughterhouse waste. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. Evaluation of the aerobic and anaerobic biodegradability of the antibiotic norfloxacin.

    Science.gov (United States)

    de Souza Santos, Lucilaine Valéria; Teixeira, Danusa Campos; Jacob, Raquel Sampaio; Amaral, Míriam Cristina Santos do; Lange, Liséte Celina

    2014-01-01

    The purpose of studying the biodegradability of pharmaceutical compounds is to evaluate their behaviors in relation to the treatment processes generally used in domestic and industrial wastewater treatment plants. The antibiotic norfloxacin was found to be a recalcitrant compound. The studies conducted showed norfloxacin removal rates of 12% and 18% when biomasses from treatments with activated sludge and anaerobic biodigesters, respectively, were used without acclimatization. This suggests that anaerobic digestion shows better performance for norfloxacin removal. Ecotoxicological tests, using the luminescent marine bacteria Aliivibrio fischeri as the test organism, show that anaerobic digestion could eliminate the toxicity of the antibiotic norfloxacin, even though total degradation of the drug was not observed. The release of norfloxacin during cell lysis suggests the importance of controlling this phenomenon in biological treatment systems that handle wastewater contaminated with norfloxacin, thus preventing the return of this drug to the environment.

  11. Metabolic interactions between methanogenic consortia and anaerobic respiring bacteria

    DEFF Research Database (Denmark)

    Stams, A.J.; Oude Elferink, S.J.; Westermann, Peter

    2003-01-01

    consortia. Despite the potentially adverse effects, only few inorganic electron acceptors potentially utilizable for anaerobic respiration have been investigated with respect to negative interactions in anaerobic digesters. In this chapter we review competitive and inhibitory interactions between anaerobic...... respiring populations and methanogenic consortia in bioreactors. Due to the few studies in anaerobic digesters, many of our discussions are based upon studies of defined cultures or natural ecosystems......Most types of anaerobic respiration are able to outcompete methanogenic consortia for common substrates if the respective electron acceptors are present in sufficient amounts. Furthermore, several products or intermediate compounds formed by anaerobic respiring bacteria are toxic to methanogenic...

  12. Prediction of rowing ergometer performance from functional anaerobic power, strength and anthropometric components.

    Science.gov (United States)

    Akça, Fırat

    2014-06-28

    The aim of this research was to develop different regression models to predict 2000 m rowing ergometer performance with the use of anthropometric, anaerobic and strength variables and to determine how precisely the prediction models constituted by different variables predict performance, when conducted together in the same equation or individually. 38 male collegiate rowers (20.17 ± 1.22 years) participated in this study. Anthropometric, strength, 2000 m maximal rowing ergometer and rowing anaerobic power tests were applied. Multiple linear regression procedures were employed in SPSS 16 to constitute five different regression formulas using a different group of variables. The reliability of the regression models was expressed by R2 and the standard error of estimate (SEE). Relationships of all parameters with performance were investigated through Pearson correlation coefficients. The prediction model using a combination of anaerobic, strength and anthropometric variables was found to be the most reliable equation to predict 2000 m rowing ergometer performance (R2 = 0.92, SEE= 3.11 s). Besides, the equation that used rowing anaerobic and strength test results also provided a reliable prediction (R2 = 0.85, SEE= 4.27 s). As a conclusion, it seems clear that physiological determinants which are affected by anaerobic energy pathways should also get involved in the processes and models used for performance prediction and talent identification in rowing.

  13. Prediction of Rowing Ergometer Performance from Functional Anaerobic Power, Strength and Anthropometric Components

    Directory of Open Access Journals (Sweden)

    Akça Firat

    2014-07-01

    Full Text Available The aim of this research was to develop different regression models to predict 2000 m rowing ergometer performance with the use of anthropometric, anaerobic and strength variables and to determine how precisely the prediction models constituted by different variables predict performance, when conducted together in the same equation or individually. 38 male collegiate rowers (20.17 ± 1.22 years participated in this study. Anthropometric, strength, 2000 m maximal rowing ergometer and rowing anaerobic power tests were applied. Multiple linear regression procedures were employed in SPSS 16 to constitute five different regression formulas using a different group of variables. The reliability of the regression models was expressed by R2 and the standard error of estimate (SEE. Relationships of all parameters with performance were investigated through Pearson correlation coefficients. The prediction model using a combination of anaerobic, strength and anthropometric variables was found to be the most reliable equation to predict 2000 m rowing ergometer performance (R2 = 0.92, SEE= 3.11 s. Besides, the equation that used rowing anaerobic and strength test results also provided a reliable prediction (R2 = 0.85, SEE= 4.27 s. As a conclusion, it seems clear that physiological determinants which are affected by anaerobic energy pathways should also get involved in the processes and models used for performance prediction and talent identification in rowing.

  14. The influence of aerobic power on repeated anaerobic exercise in junior soccer players.

    Science.gov (United States)

    Cipryan, Lukas; Gajda, Vojtech

    2011-06-01

    The main purpose of the present study is to investigate the relationship between anaerobic power achieved in repeated anaerobic exercise and aerobic power. The study group consisted of 40 soccer players (age 17.3 ± 1.36 years). All participants performed 3 tests: a running-based anaerobic sprint test (RAST), a graded treadmill test (GXT), and a multistage fitness test (20mPST). A statistically significant correlation was found among peak power in the GXT and the maximum (r = 0.365, p=0.02), minimum (r=0.334, p=0.035) and average (r=0.401, p=0.01) power in the RAST. No relationships were found between VO2max obtained from both aerobic tests and any performance indices in the RAST. A statistically significant correlation was found between the VO2max obtained from the spiroergometry examination (GXT) and the calculated VO2max of 20mPST (r=0.382, p=0.015). In conclusion, the level of VO2max does not influence the performance indices in the RAST in elite junior soccer players. It is possible that the modification of anaerobic test protocol or a more heterogeneous study group would influence the results. The estimation of the VO2max in the 20mPST is too inaccurate and should not replace the laboratory spiroergometry examination.

  15. Biomass stabilization in the anaerobic digestion of wastewater sludges

    Energy Technology Data Exchange (ETDEWEB)

    Arnaiz, C. [Universidad de Sevilla, Dept. de Ingenieria Quimica y Ambiental, Sevilla (Spain); Gutierrez, J.C. [Universidad Pablo de Olavide, Dept. de Ciencias Ambientales, Sevilla (Spain); Lebrato, J. [Universidad de Sevilla, Grupo Tratamiento de Aguas Residuales, Sevilla (Spain)

    2005-07-01

    Sludge stabilization processes include both volatile solid destruction and biomass stabilization. Traditionally, both processes have been considered together, in such a way that, when volatile solid destruction is achieved, the biomass is considered stabilized. In this study, volatile solids reduction and biomass stabilization in the anaerobic digestion of primary, secondary and mixed sludges from municipal wastewater treatment plants were researched in batch cultures by measurements of suspended solids and suspended lipid-phosphate. The estimated kinetic constants were higher in all sludge types tested for the biomass stabilization process, indicating that volatile solids destruction and biomass stabilization are not parallel processes, since the latter one is reached before the former. (Author)

  16. Biomass stabilization in the anaerobic digestion of wastewater sludges

    Energy Technology Data Exchange (ETDEWEB)

    Arnaiz, C. [Universidad de Sevilla (Spain). Escuela Universitaria Politecnica. Departamento de Ingenieria Quimica y Ambiental; Gutierrez, J.C. [Universidad Pablo de Olavide, Sevilla (Spain). Departamento de Ciencias Ambientales; Lebrato, J. [Universidad de Sevilla (Spain). Escuela Universitaria Politecnica

    2006-07-15

    Sludge stabilization processes include both volatile solid destruction and biomass stabilization. Traditionally, both processes have been considered together, in such a way that, when volatile solid destruction is achieved, the biomass is considered stabilized. In this study, volatile solids reduction and biomass stabilization in the anaerobic digestion of primary, secondary and mixed sludges from municipal wastewater treatment plants were researched in batch cultures by measurements of suspended solids and suspended lipid-phosphate. The estimated kinetic constants were higher in all sludge types tested for the biomass stabilization process, indicating that volatile solids destruction and biomass stabilization are not parallel processes, since the latter one is reached before the former. (author)

  17. A proposed taxonomy of anaerobic fungi (class neocallimastigomycetes suitable for large-scale sequence-based community structure analysis.

    Directory of Open Access Journals (Sweden)

    Sandra Kittelmann

    Full Text Available Anaerobic fungi are key players in the breakdown of fibrous plant material in the rumen, but not much is known about the composition and stability of fungal communities in ruminants. We analyzed anaerobic fungi in 53 rumen samples from farmed sheep (4 different flocks, cattle, and deer feeding on a variety of diets. Denaturing gradient gel electrophoresis fingerprinting of the internal transcribed spacer 1 (ITS1 region of the rrn operon revealed a high diversity of anaerobic fungal phylotypes across all samples. Clone libraries of the ITS1 region were constructed from DNA from 11 rumen samples that had distinctly different fungal communities. A total of 417 new sequences were generated to expand the number and diversity of ITS1 sequences available. Major phylogenetic groups of anaerobic fungi in New Zealand ruminants belonged to the genera Piromyces, Neocallimastix, Caecomyces and Orpinomyces. In addition, sequences forming four novel clades were obtained, which may represent so far undetected genera or species of anaerobic fungi. We propose a revised phylogeny and pragmatic taxonomy for anaerobic fungi, which was tested and proved suitable for analysis of datasets stemming from high-throughput next-generation sequencing methods. Comparing our revised taxonomy to the taxonomic assignment of sequences deposited in the GenBank database, we believe that >29% of ITS1 sequences derived from anaerobic fungal isolates or clones are misnamed at the genus level.

  18. Anaerobic co-digestion of dairy manure and potato waste

    Science.gov (United States)

    Yadanaparthi, Sai Krishna Reddy

    Dairy and potato are two important agricultural commodities in Idaho. Both the dairy and potato processing industries produce a huge amount of waste which could cause environmental pollution. To minimize the impact of potential pollution associated with dairy manure (DM) and potato waste (PW), anaerobic co-digestion has been considered as one of the best treatment process. The purpose of this research is to evaluate the anaerobic co-digestion of dairy manure and potato waste in terms of process stability, biogas generation, construction and operating costs, and potential revenue. For this purpose, I conducted 1) a literature review, 2) a lab study on anaerobic co-digestion of dairy manure and potato waste at three different temperature ranges (ambient (20-25°C), mesophilic (35-37°C) and thermophilic (55-57°C) with five mixing ratios (DM:PW-100:0, 90:10, 80:20, 60:40, 40:60), and 3) a financial analysis for anaerobic digesters based on assumed different capital costs and the results from the lab co-digestion study. The literature review indicates that several types of organic waste were co-digested with DM. Dairy manure is a suitable base matter for the co-digestion process in terms of digestion process stability and methane (CH4) production (Chapter 2). The lab tests showed that co-digestion of DM with PW was better than digestion of DM alone in terms of biogas and CH4 productions (Chapter 3). The financial analysis reveals DM and PW can be used as substrate for full size anaerobic digesters to generate positive cash flow within a ten year time period. Based on this research, the following conclusions and recommendations were made: ▸ The ratio of DM:PW-80:20 is recommended at thermophilic temperatures and the ratio of DM:PW-90:10 was recommended at mesophilic temperatures for optimum biogas and CH4 productions. ▸ In cases of anaerobic digesters operated with electricity generation equipment (generators), low cost plug flow digesters (capital cost of 600/cow

  19. Multivariate monitoring of anaerobic co-digestion

    DEFF Research Database (Denmark)

    Madsen, Michael; Holm-Nielsen, Jens Bo

    warming and environmental concerns. Anaerobic digestion applied in agriculture can simultaneously convert heterogeneous biomasses and wastes from the primary agricultural sector and from the bio processing industries, for instance food processing, pharma, and biofuel production, into valuable organic...... fertiliser and renewable energy. Meanwhile, in order for the biogas sector to become a significant player in the energy supply chain, the anaerobic digestion process has to be controlled to a greater extent than what is implemented as state-of-the-art today. Through application of the philosophy behind...... Process Analytical Technology, well-known from the pharmaceutical sector, these objectives can be realised. NIRS and chemometrics are key technologies in this concern. The feasibility studies summarised in this paper concerns at-line and on-line PAT monitoring of anaerobic digestion processes at several...

  20. Biochemistry and physiology of anaerobic bacteria

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-05-18

    We welcome you to The Power of Anaerobes. This conference serves two purposes. One is to celebrate the life of Harry D. Peck, Jr.,who was born May 18, 1927 and would have celebrated his 73rd birthday at this conference. He died November 20, 1998. The second is to gather investigators to exchange views within the realm of anaerobic microbiology, an area in which tremendous progress has been seen during recent years. It is sufficient to mention discoveries of a new form of life (the archaea), hyper or extreme thermophiles, thermophilic alkaliphiles and anaerobic fungi. With these discoveries has come a new realization about physiological and metabolic properties of microorganisms, and this in turn has demonstrated their importance for the development, maintenance and sustenance of life on Earth.

  1. Kinetics and modeling of anaerobic digestion process

    DEFF Research Database (Denmark)

    Gavala, Hariklia N.; Angelidaki, Irini; Ahring, Birgitte Kiær

    2003-01-01

    Anaerobic digestion modeling started in the early 1970s when the need for design and efficient operation of anaerobic systems became evident. At that time not only was the knowledge about the complex process of anaerobic digestion inadequate but also there were computational limitations. Thus......, the first models were very simple and consisted of a limited number of equations. During the past thirty years much research has been conducted on the peculiarities of the process and on the factors that influence it on the one hand while an enormous progress took place in computer science on the other....... The combination of both parameters resulted in the development of more and more concise and complex models. In this chapter the most important models found in the literature are described starting from the simplest and oldest to the more recent and complex ones....

  2. Kinetics and modeling of anaerobic digestion process.

    Science.gov (United States)

    Gavala, Hariklia N; Angelidaki, Irini; Ahring, Birgitte K

    2003-01-01

    Anaerobic digestion modeling started in the early 1970s when the need for design and efficient operation of anaerobic systems became evident. At that time not only was the knowledge about the complex process of anaerobic digestion inadequate but also there were computational limitations. Thus, the first models were very simple and consisted of a limited number of equations. During the past thirty years much research has been conducted on the peculiarities of the process and on the factors that influence it on the one hand while an enormous progress took place in computer science on the other. The combination of both parameters resulted in the development of more and more concise and complex models. In this chapter the most important models found in the literature are described starting from the simplest and oldest to the more recent and complex ones.

  3. Alpine skiing and anaerobic performance in solid organ transplant recipients.

    Science.gov (United States)

    Roi, G S; Mosconi, G; Capelli, I; Cuna, V; Persici, E; Parigino, M; Pisoni, D; Todeschini, P; Costa, A Nanni; Stefoni, S

    2010-05-01

    Limited information has been published about sporting activities in solid organ transplant recipients. The aim of this study was to assess "in the field" performance capacities of a group of transplant recipients involved in an alpine skiing competition. We studied 16 transplant recipients (13 men and 3 women) who had undergone transplantations (11 kidney, 4 liver, and 1 heart) at 89 +/- 68 months prior while participating in an alpine skiing race. The patients performed a countermovement jumping test to measure the explosive power of the lower limbs. In all patients blood lactate concentrations (La) were measured at the end of a giant slalom race. The maximum displacement of the center of mass during the jumping test was 22.4 +/- 9.3 cm; the time to complete the giant slalom was 75.5 +/- 16.5 seconds and La was 3.5 +/- 0.8 mmol/L. We observed significant linear relationships between race time and La (R(2) = 0.4733; P < .01) and between race time and performance in the jumping test (R(2) = 0.3655; P < .05). This study indicated that recovery of anaerobic and technical sporting activities is possible in organ transplant recipients. Muscular power and anaerobic performances among a selected group of solid organ transplant recipients were similar to those of the general untrained population. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  4. Improving Project Outcomes and Growing the Anaerobic Digestion Industy Report

    Science.gov (United States)

    Anaerobic digestion ombudsmen assist with project development, ensure the long-term sustainability of projects, and help advance the industry. This report explores the benefits of anaerobic digestion ombudsmen and provides guidance for implementing them.

  5. The effect of tannic compounds on anaerobic wastewater treatment

    NARCIS (Netherlands)

    Field, J.A.

    1989-01-01

    Anaerobic wastewater treatment is an alternative to the conventional aerobic treatment processes for the removal of easily biodegradable organic matter in medium to high strength industrial wastestreams. Anaerobic treatment has several advantages, however one important disadvantage is the

  6. Glycine propionyl-L-carnitine produces enhanced anaerobic work capacity with reduced lactate accumulation in resistance trained males

    Directory of Open Access Journals (Sweden)

    Orem Ihsan

    2009-04-01

    Full Text Available Abstract Background Recent research has indicated that short term administration of glycine propionyl-L-carnitine (GPLC significantly elevates levels of nitric oxide metabolites at rest and in response to reactive hyperaemia. However, no scientific evidence exists that suggests such supplementation enhances exercise performance in healthy, trained individuals. The purpose of this study was to examine the effects of GPLC on the performance of repeated high intensity stationary cycle sprints with limited recovery periods in resistance trained male subjects. Methods In a double-blind, placebo-controlled, cross-over design, twenty-four male resistance trained subjects (25.2 ± 3.6 years participated in two test sessions separated by one week. Testing was performed 90 minutes following oral ingestion of either 4.5 grams GPLC or 4.5 grams cellulose (PL, in randomized order. The exercise testing protocol consisted of five 10-second Wingate cycle sprints separated by 1-minute active recovery periods. Peak (PP and mean values (MP of sprint power output and percent decrement of power (DEC were determined per bout and standardized relative to body masss. Heart rate (HR and blood lactate (LAC were measured prior to, during and following the five sprint bouts. Results Significant main effects (p Conclusion These findings indicate that short-term oral supplementation of GPLC can enhance peak power production in resistance trained males with significantly less LAC accumulation.

  7. Enhanced anaerobic digestion of food waste by thermal and ozonation pretreatment methods.

    Science.gov (United States)

    Ariunbaatar, Javkhlan; Panico, Antonio; Frunzo, Luigi; Esposito, Giovanni; Lens, Piet N L; Pirozzi, Francesco

    2014-12-15

    Treatment of food waste by anaerobic digestion can lead to an energy production coupled to a reduction of the volume and greenhouse gas emissions from this waste type. According to EU Regulation EC1774/2002, food waste should be pasteurized/sterilized before or after anaerobic digestion. With respect to this regulation and also considering the slow kinetics of the anaerobic digestion process, thermal and chemical pretreatments of food waste prior to mesophilic anaerobic digestion were studied. A series of batch experiments to determine the biomethane potential of untreated as well as pretreated food waste was carried out. All tested conditions of both thermal and ozonation pretreatments resulted in an enhanced biomethane production. The kinetics of the anaerobic digestion process were, however, accelerated by thermal pretreatment at lower temperatures (food waste, was obtained with thermal pretreatment at 80 °C for 1.5 h. On the basis of net energy calculations, the enhanced biomethane production could cover the energy requirement of the thermal pretreatment. In contrast, the enhanced biomethane production with ozonation pretreatment is insufficient to supply the required energy for the ozonator. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Comparative performance evaluation of full-scale anaerobic and aerobic wastewater treatment processes in Brazil.

    Science.gov (United States)

    von Sperling, M; Oliveira, S C

    2009-01-01

    This article evaluates and compares the actual behavior of 166 full-scale anaerobic and aerobic wastewater treatment plants in operation in Brazil, providing information on the performance of the processes in terms of the quality of the generated effluent and the removal efficiency achieved. The observed results of effluent concentrations and removal efficiencies of the constituents BOD, COD, TSS (total suspended solids), TN (total nitrogen), TP (total phosphorus) and FC (faecal or thermotolerant coliforms) have been compared with the typical expected performance reported in the literature. The treatment technologies selected for study were: (a) predominantly anaerobic: (i) septic tank + anaerobic filter (ST + AF), (ii) UASB reactor without post-treatment (UASB) and (iii) UASB reactor followed by several post-treatment processes (UASB + POST); (b) predominantly aerobic: (iv) facultative pond (FP), (v) anaerobic pond followed by facultative pond (AP + FP) and (vi) activated sludge (AS). The results, confirmed by statistical tests, showed that, in general, the best performance was achieved by AS, but closely followed by UASB reactor, when operating with any kind of post-treatment. The effluent quality of the anaerobic processes ST + AF and UASB reactor without post-treatment was very similar to the one presented by facultative pond, a simpler aerobic process, regarding organic matter.

  9. Effect of anaerobic digestion on oocysts of the protozoan Eimeria tenella.

    Science.gov (United States)

    Lee, M R; Shih, J C

    1988-10-01

    The effect of anaerobic digestion of poultry waste on oocysts of the protozoan Eimeria tenella, a common enteric pathogen that causes coccidiosis in poultry, was investigated in this study. Thermophilic (50 degrees C) and mesophilic (35 degrees C) anaerobic digestors, with poultry manure as the substrate, were inoculated with the oocysts. The oocysts were damaged during anaerobic digestion, as determined by morphological change and loss of their ability to sporulate. The recovered oocysts were tested for their infectivity in young chicks, as measured by body weight gain, mortality, and cecal lesions. Oocysts lost all their infectivity during thermophilic digestion, while oocysts subjected to mesophilic digestion remained moderately infective in comparison with untreated oocysts, which produced severe coccidiosis, high mortality, and low body weight gain in chicks. Oocysts were inactivated at 50 degrees C when they were suspended in digestor fluid or saline. Inactivation at 35 degrees C was significantly stronger in the digestor fluid than in the saline, which implied that factors other than temperature were involved in the lethal effect of anaerobic digestion on protozoan oocysts. In this study we demonstrated that the treatment of animal waste by anaerobic digestion, especially at a thermophilic temperature, has the benefits of pathogen control and protection of human and animal health in a farm environment.

  10. Effect of tapering on anaerobic power and capacity of tae-kwon-do athletes

    Directory of Open Access Journals (Sweden)

    Leonardo de Sousa Fortes

    2017-05-01

    Full Text Available DOI: http://dx.doi.org/10.5007/1980-0037.2017v19n2p224   The aim of the study was to analyze the effect of a tapering period on anaerobic power and capacity of tae-kwon-do athletes. Thirty-one male tae-kwon-do participants of the Brazilian Championship were selected in a non-probabilistic way. Subjects were randomly divided into two groups, namely: experimental group (EG, n = 15 and control group (CG, n = 17. Both groups followed the same training protocol up to the tapering stage. CG was submitted to training loads contained in the last two weeks of the macrocycle. Only EG was submitted to tapering. Tapering had 2 weeks duration, adopting the linear tapering method. Taekwondo Anaerobic Test was performed by athletes before the start of the season, which was named as pre-intervention, and the last week of each mesocycle [Prep I, Prep II and Tapering (only EG]. Group vs. time effect interaction (p < 0.01 was identified for alactic anaerobic power, with an increase only in EG in tapering (p = 0.01. A significant group vs. time interaction (p <0.01 was revealed to fatigue index, improved anaerobic capacity being checked in EG only after the tapering period (p = 0.01. It was concluded that two weeks of linear type tapering optimized the anaerobic power and capacity of male tae-kwon-do athletes.

  11. A simple anaerobic system for onsite treatment of domestic wastewater

    African Journals Online (AJOL)

    user

    The use of anaerobic process for domestic wastewater treatment would achieve lower carbon footprint as it eliminates aeration and generate methane. Among several anaerobic treatment processes, high rate anaerobic digesters receive great attention due to its high loading capacity and chemical oxygen demand removal ...

  12. Toxicity and biodegradability of caffeic acid in anaerobic digesting ...

    African Journals Online (AJOL)

    ... to treat waste caffeic acid by anaerobic digestion and adsorption of its derivates, in order to reduce the contribution to global warming and to protect the environment. Keywords: anaerobes, anaerobic digestion, biogas, biomass, caffeic acid, graphene, inhibition, polyphenols, renewable energy, toxicity, wastewater ...

  13. Optimization of up-flow anaerobic sludge blanket reactor for ...

    African Journals Online (AJOL)

    aghomotsegin

    2013-06-05

    Jun 5, 2013 ... Key words: Composite wastewater, up-flow anaerobic sludge blanket (UASB), anaerobic biological treatment, biogas, granulated anaerobic ... collected from the top of the reactor to a flexible water-filled gasholder fitted with .... changes in microbial diversity in biogranules in response to changes in nature ...

  14. The Influence of Hydration on Anaerobic Performance: A Review

    Science.gov (United States)

    Kraft, Justin A.; Green, James M.; Bishop, Phillip A.; Richardson, Mark T.; Neggers, Yasmin H.; Leeper, James D.

    2012-01-01

    This review examines the influence of dehydration on muscular strength and endurance and on single and repeated anaerobic sprint bouts. Describing hydration effects on anaerobic performance is difficult because various exercise modes are dominated by anaerobic energy pathways, but still contain inherent physiological differences. The critical…

  15. The IWA Anaerobic Digestion Model No 1 (ADM1)

    NARCIS (Netherlands)

    Batstone, D.J.; Keller, J.; Angelidaki, I.; Kalyuzhnyi, S.V.; Pavalostathis, S.G.; Rozzi, A.; Sanders, W.T.M.; Siegrist, H.; Vavilin, V.A.

    2002-01-01

    The IWA Anaerobic Digestion Modelling Task Group was established in 1997 at the 8th World Congress on Anaerobic Digestion (Sendai, Japan) with the goal of developing a generalised anaerobic digestion model. The structured model includes multiple steps describing biochemical as well as

  16. The IWA Anaerobic digestion model no 1. (ADM1)

    DEFF Research Database (Denmark)

    Batstone, Damien J.; Keller, J.; Angelidaki, Irini

    2002-01-01

    The IWA Anaerobic Digestion Modelling Task Group was established in 1997 at the 8th World Congress on Anaerobic Digestion (Sendai, Japan) with the goal of developing a generalised anaerobic digestion model. The structured model includes multiple steps describing biochemical as well...

  17. Anaerobic Digestion. Student Manual. Biological Treatment Process Control.

    Science.gov (United States)

    Carnegie, John W., Ed.

    This student manual contains the textual material for a four-lesson unit on anaerobic digestion control. Areas addressed include: (1) anaerobic sludge digestion (considering the nature of raw sludge, purposes of anaerobic digestion, the results of digestion, types of equipment, and other topics); (2) digester process control (considering feeding…

  18. Anaerobic treatment of domestic sewage at low temperature

    NARCIS (Netherlands)

    Elmitwalli, T.A.

    2000-01-01

    The main objective of this thesis was to asses the anaerobic treatment of domestic sewage at low temperature and the possibilities to optimize the performance of high-rate anaerobic systems treating domestic sewage at low temperature.

    The anaerobic biodegradability of

  19. The effect of sleep deprivation on choice reaction time and anaerobic power of college student athletes.

    Science.gov (United States)

    Taheri, Morteza; Arabameri, Elaheh

    2012-03-01

    The aim of this study was to determine the effect of one night's sleep deprivation on anaerobic performance and Reaction time of subjects in the morning of the following day. Eighteen male college student athletes were studied twice in a balanced, randomized design. Subjects were measured for peak power, mean power and Reaction time. The performance showed no significant difference in both tests of anaerobic power (peak power, mean power) over the sleep deprivation period (P= 0.3; P= 0.4 respectively), but reaction time differed significantly from baseline (P=0.003). Results support the hypothesis that sleep serves a function of cognitive restitution, particularly in the maintenance of attentional mechanisms. In the light of the above considerations. It was concluded that short-term sleep deprivation is not effective on anaerobic performance, but adversely affects cognitive function such as Reaction Time.

  20. Effect of initial bulk density on high-solids anaerobic digestion of MSW: General mechanism.

    Science.gov (United States)

    Caicedo, Luis M; Wang, Hongtao; Lu, Wenjing; De Clercq, Djavan; Liu, Yanjun; Xu, Sai; Ni, Zhe

    2017-06-01

    Initial bulk density (IBD) is an important variable in anaerobic digestion since it defines and optimizes the treatment capacity of a system. This study reveals the mechanism on how IBD might affect anaerobic digestion of waste. Four different IBD values: D1 (500-700kgm-3), D2 (900-1000kgm-3), D3 (1100-1200kgm-3) and D4 (1200-1400kgm-3) were set and tested over a period of 90days in simulated landfill reactors. The main variables affected by the IBD are the methane generation, saturation degree, extraction of organic matter, and the total population of methanogens. The study identified that IBD >1000kgm-3 may have significant effect on methane generation, either prolonging the lag time or completely inhibiting the process. This study provides a new understanding of the anaerobic digestion process in saturated high-solids systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. [Anaerobic effect of tinidazol compared with metronidazol, ornidazol, cefoxitin and lamoxactam].

    Science.gov (United States)

    Werner, H; Kuchenbecker, K; Hammann, R

    1983-06-01

    The in vitro inhibitory activity of tinidazole, metronidazole, ornidazole, cefoxitin and moxalactam was determined against 150 isolates of clinically important anaerobes including Bacteroides fragilis, Bacteroides bivius and Clostridium perfringens by means of agar dilution tests. The members of 18 gramnegative and 14 grampositive species were inhibited by tinidazole at less than or equal to 0,01-8 micrograms/ml thus being without exception susceptible to the drug. A similar in vitro activity was recorded for metronidazole and ornidazole. Though cefoxitin and moxalactam generally had a good in vitro activity against most anaerobic species, single strains of Bacteroides thetaiotaomicron, B. distasonis, Clostridium difficile and Eubacterium rectale were resistant to these drugs. With regard to its in vitro activity, tinidazole seems to be a promising substance for the therapy of anaerobic infections.

  2. Determining the anaerobic threshold in postpolio syndrome: comparison with current guidelines for training intensity prescription

    NARCIS (Netherlands)

    Voorn, Eric L.; Gerrits, Karin H.; Koopman, Fieke S.; Nollet, Frans; Beelen, Anita

    2014-01-01

    To determine whether the anaerobic threshold (AT) can be identified in individuals with postpolio syndrome (PPS) using submaximal incremental exercise testing, and to compare current guidelines for intensity prescription in PPS with the AT. Cohort study. Research laboratory. Individuals with PPS

  3. Evaluation of biogas production potential by dry anaerobic digestion of switchgrass--animal manure mixtures.

    Science.gov (United States)

    Ahn, H K; Smith, M C; Kondrad, S L; White, J W

    2010-02-01

    Anaerobic digestion is a biological method used to convert organic wastes into a stable product for land application with reduced environmental impacts. The biogas produced can be used as an alternative renewable energy source. Dry anaerobic digestion [>15% total solid (TS)] has an advantage over wet digestion (produces a fertilizer that is easier to transport. Performance of anaerobic digestion of animal manure-switchgrass mixture was evaluated under dry (15% TS) and thermophilic conditions (55 degrees C). Three different mixtures of animal manure (swine, poultry, and dairy) and switchgrass were digested using batch-operated 1-L reactors. The swine manure test units showed 52.9% volatile solids (VS) removal during the 62-day trial, while dairy and poultry manure test units showed 9.3% and 20.2%, respectively. Over the 62 day digestion, the swine manure test units yielded the highest amount of methane 0.337 L CH4/g VS, while the dairy and poultry manure test units showed very poor methane yield 0.028 L CH4/g VS and 0.002 L CH4/g VS, respectively. Although dairy and poultry manure performed poorly, they may still have high potential as biomass for dry anaerobic digestion if appropriate designs are developed to prevent significant volatile fatty acid (VFA) accumulation and pH drop.

  4. The influence of anaerobic muscle activity, maturation and season on the flesh quality of farmed turbot

    NARCIS (Netherlands)

    Roth, B.; Imsland, A.; Stien, L.H.; Schelvis-Smit, A.A.M.; Gunnarsson, S.; Foss, A.

    2010-01-01

    In order to test seasonal, rearing, maturing and anaerobic muscle activity effect on the flesh quality of turbot (Scophthalmus maximus) a total of 80 farmed turbot from three different strains from reared under natural or continuous light were killed by a percussive blow to the head in November

  5. Massive insulin secretion in response to anaerobic exercise in exercise-induced hyperinsulinism.

    Science.gov (United States)

    Meissner, T; Friedmann, B; Okun, J G; Schwab, M A; Otonkoski, T; Bauer, T; Bärtsch, P; Mayatepek, E

    2005-11-01

    Exercise-induced hyperinsulinism (EIHI) is a recently described entity characterised by recurrent episodes of hypoglycaemia induced by physical exercise. The index patient for this disorder and a matched control were subjected to aerobic and anaerobic exercise tests on a cycle ergometer. Aerobic exercise was performed at an intensity of 60% of the respective 4 mmol/l lactate threshold (40 min). Anaerobic exercise with an intensity corresponding to 130% VO2max lead to exertion within 2-3 min and elicited comparable maximal lactate levels in both subjects (10-11 mmol/l). The patient experienced a massive increase in insulin from 34 to 649 mU/l after the anaerobic test, and a lower increase in insulin from 27 to 79 mU/l during the aerobic test. Insulin concentration remained unchanged during both tests in the control. Epinephrine increased in the EIHI patient, which was probably a counterregulatory response to hypoglycaemia. The activity of lactate dehydrogenase of the index patient in isolated leukocytes as well as the response to inhibition of oxamate was normal. The hypothesis of abnormal transport or metabolism of lactate/pyruvate in the beta-cells of patients with EIHI was further supported by the parallel increase of lactate and insulin in this study elicited in particular by anaerobic exercise.

  6. Active Female Maximal and Anaerobic Threshold Cardiorespiratory Responses to Six Different Water Aerobics Exercises

    Science.gov (United States)

    Antunes, Amanda H.; Alberton, Cristine L.; Finatto, Paula; Pinto, Stephanie S.; Cadore, Eduardo L.; Zaffari, Paula; Kruel, Luiz F. M.

    2015-01-01

    Purpose: Maximal tests conducted on land are not suitable for the prescription of aquatic exercises, which makes it difficult to optimize the intensity of water aerobics classes. The aim of the present study was to evaluate the maximal and anaerobic threshold cardiorespiratory responses to 6 water aerobics exercises. Volunteers performed 3 of the…

  7. Total Protein of Whole Saliva as a Biomarker of Anaerobic Threshold

    Science.gov (United States)

    Bortolini, Miguel Junior Sordi; De Agostini, Guilherme Gularte; Reis, Ismair Teodoro; Lamounier, Romeu Paulo Martins Silva; Blumberg, Jeffrey B.; Espindola, Foued Salmen

    2009-01-01

    Saliva provides a convenient and noninvasive matrix for assessing specific physiological parameters, including some biomarkers of exercise. We investigated whether the total protein concentration of whole saliva (TPWS) would reflect the anaerobic threshold during an incremental exercise test. After a warm-up period, 13 nonsmoking men performed a…

  8. Response of anaerobic carbon cycling to water table manipulation in an Alaskan rich fen

    Science.gov (United States)

    E.S. Kane; M.R. Chivers; M.S. Turetsky; C.C. Treat; D.G. Petersen; M. Waldrop; J.W. Harden; A.D. McGuire

    2013-01-01

    To test the effects of altered hydrology on organic soil decomposition, we investigated CO2 and CH4 production potential of rich-fen peat (mean surface pH = 6.3) collected from a field water table manipulation experiment including control, raised and lowered water table treatments. Mean anaerobic CO2...

  9. Selection of suitable fertilizer draw solute for a novel fertilizer-drawn forward osmosis-anaerobic membrane bioreactor hybrid system

    KAUST Repository

    Kim, Youngjin

    2016-02-09

    In this study, a protocol for selecting suitable fertilizer draw solute for anaerobic fertilizer-drawn forward osmosis membrane bioreactor (AnFDFOMBR) was proposed. Among eleven commercial fertilizer candidates, six fertilizers were screened further for their FO performance tests and evaluated in terms of water flux and reverse salt flux. Using selected fertilizers, bio-methane potential experiments were conducted to examine the effect of fertilizers on anaerobic activity due to reverse diffusion. Mono-ammonium phosphate (MAP) showed the highest biogas production while other fertilizers exhibited an inhibition effect on anaerobic activity with solute accumulation. Salt accumulation in the bioreactor was also simulated using mass balance simulation models. Results showed that ammonium sulphate and MAP were the most appropriate for AnFDFOMBR since they demonstrated less salt accumulation, relatively higher water flux, and higher dilution capacity of draw solution. Given toxicity of sulphate to anaerobic microorganisms, MAP appears to be the most suitable draw solution for AnFDFOMBR.

  10. Impact of ammonia and sulphate concentration on thermophilic anaerobic digestion.

    Science.gov (United States)

    Siles, J A; Brekelmans, J; Martín, M A; Chica, A F; Martín, A

    2010-12-01

    The effect of increasing concentrations of ammonia and sulphate on thermophilic anaerobic digestion (52 degrees C) was studied at laboratory-scale. The substrate consisted of a synthetic solution supplemented with ammonia and sodium sulphate. In terms of biogas production, the results showed that the C/N and C/SO(4)(2-) thresholds were 4.40 and 1.60, respectively, corresponding to 620 mg FA (free ammonia)/L and 1400 mg SO(4)(2-)/L. No reduction in biogas production was observed until reaching the above concentration of sulphate in the sulphate toxicity test. However, when the concentration of ammonia was increased to 620 mg FA/L in the ammonia toxicity test, a gradual decrease of 21% was observed for the biogas. In order to characterise each set of experiments kinetically, a biogas production first-order kinetic model was used to fit the experimental data. The proposed model accurately predicted the behaviour of the microorganisms affecting the thermophilic anaerobic digestion, allowing its evolution to be predicted. 2010 Elsevier Ltd. All rights reserved.

  11. Environmental impacts of anaerobic digestion and the use of anaerobic residues as soil amendment

    Energy Technology Data Exchange (ETDEWEB)

    Mosey, F.E. [VFA Services Ltd., Herts (United Kingdom)

    1996-01-01

    This paper defines the environmental role of anaerobic digestion within the overall objective of recovering energy from renewable biomass resources. Examples and opportunities for incorporating anaerobic digestion into biomass-to-energy schemes are discussed, together with environmental aspects of anaerobic digestion plants. These include visual, public amenity, pathogens and public health, odor control, and gaseous emissions. Digestate disposal and the benefits of restrictions on recycling organic wastes and biomass residues back to the land are discussed, particularly as they relate to American and European codes of practice and environmental legislation. The paper concludes that anaerobic digestion, if performed in purpose-designed reactors that efficiently recover and use biogas, is an environmentally benign process that can enhance energy recovery and aid the beneficial land use of plant residues in many biomass-to-energy schemes.

  12. Anaerobic digestion model no. 1-based distributed parameter model of an anaerobic reactor: I. Model development.

    Science.gov (United States)

    Mu, S J; Zeng, Y; Wu, P; Lou, S J; Tartakovsky, B

    2008-06-01

    This work presents a distributed parameter model of the anaerobic digestion process. The model is based on the Anaerobic digestion model no. 1 (ADM1) and was developed to simulate anaerobic digestion process in high-rate reactors with significant axial dispersion, such as in upflow anaerobic sludge bed (UASB) reactors. The model, which was named ADM1d, combines ADM1's kinetics of biomass growth and substrate transformation with axial dispersion material balances. ADM1d uses a hyperbolic tangent function to describe biomass distribution within a one compartment model. A comparison of this approach with a two-compartment, sludge bed - liquid above the bed, model showed similar simulation results while the one-compartment model had less equations. A comparison of orthogonal collocation and finite difference algorithms for numerical solution of ADM1d showed better stability of the finite difference algorithm.

  13. Hemicellulases from anaerobic thermophiles. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Wiegel, J.

    1994-05-01

    The longterm goal of this research effort is to obtain an anaerobic thermophilic bacterium that efficiently converts various hemicellulose-containing biomass to ethanol over a broad pH range. The strategy is to modify the outfit and regulation of the rate-limiting xylanases, glycosidases and xylan esterases in the ethanologenic, anaerobic thermophile Thermoanaerobacter ethanolicus, which grows between pH 4.5 and 9.5. Although it utilizes xylans, the xylanase, acetyl(xylan) esterase and O-methylglucuronidase activities in T. ethanolicus are barely measurable and regarded as the rate limiting steps in its xylan utilization. Thus, and also due to the presently limited knowledge of hemicellulases in anaerobic thermophiles, we characterize the hemicellulolytic enzymes from this and other anaerobic thermophiles as enzyme donors. Beside the active xylosidase/arabinosidase from T. ethanolicus, exhibiting the two different activities, we characterized 2 xylosidases, two acetyl(xylan) esterases, and an O-methylglucuronidase from Thermoanaerobacterium spec. We will continue with the characterization of xylanases from novel isolated slightly acidophilic, neutrophilic and slightly alkalophilic thermophiles. We have cloned, subcloned and partially sequenced the 165,000 Da (2 x 85,000) xylosidase/arabinosidase from T. ethanolicus and started with the cloning of the esterases from Thermoanaerobacterium spec. Consequently, we will develop a shuttle vector and continue to apply electroporation of autoplasts as a method for cloning into T. ethanolicus.

  14. Anaerobic hydrolysis during digestion of complex substrates

    NARCIS (Netherlands)

    Sanders, W.T.M.

    2001-01-01

    Complex waste(water) such as, raw sewage, dairy wastewater, slaughterhouse wastewater, fish processing wastewater, primary sludge and the organic fraction of municipal solid waste have been proven to be degradable under anaerobic conditions. However, during the digestion process the

  15. Anaerobic digestion in sustainable biomass chains

    NARCIS (Netherlands)

    Pabon Pereira, C.P.

    2009-01-01

    This thesis evaluates the potential contribution of anaerobic digestion (AD) to the sustainability of biomass chains. Results provide insights in the technological potential to recover energy and valuable by-products from energy crops and residues, and evaluate biomass cascades involving AD

  16. Anaerobic effluent disinfection using ozone: Byproducts formation

    NARCIS (Netherlands)

    Silva, G.H.R.; Daniel, L.A.; Bruning, H.; Rulkens, W.H.

    2010-01-01

    This research was aimed at studying oxidation processes, coliform inactivation effectiveness and disinfection byproducts (DBPs) associated with the disinfection of anaerobic sanitary wastewater effluent with ozone applied at doses of 5.0, 8.0 and 10.0mg O(3)L(-1) for contact times of 5, 10 and 15

  17. Anaerobic membrane bioreactors: Are membranes really necessary?

    NARCIS (Netherlands)

    Davila, M.; Kassab, G.; Klapwijk, A.; Lier, van J.B.

    2008-01-01

    Membranes themselves represent a significant cost for the full scale application of anaerobic membrane bioreactors (AnMBR). The possibility of operating an AnMBR with a self-forming dynamic membrane generated by the substances present in the reactor liquor would translate into an important saving. A

  18. Biofilm-growing intestinal anaerobic bacteria.

    Science.gov (United States)

    Donelli, Gianfranco; Vuotto, Claudia; Cardines, Rita; Mastrantonio, Paola

    2012-07-01

    Sessile growth of anaerobic bacteria from the human intestinal tract has been poorly investigated, so far. We recently reported data on the close association existing between biliary stent clogging and polymicrobial biofilm development in its lumen. By exploiting the explanted stents as a rich source of anaerobic bacterial strains belonging to the genera Bacteroides, Clostridium, Fusobacterium, Finegoldia, Prevotella, and Veillonella, the present study focused on their ability to adhere, to grow in sessile mode and to form in vitro mono- or dual-species biofilms. Experiments on dual-species biofilm formation were planned on the basis of the anaerobic strains isolated from each clogged biliary stent, by selecting those in which a couple of anaerobic strains belonging to different species contributed to the polymicrobial biofilm development. Then, strains were investigated by field emission scanning electron microscopy and confocal laser scanning microscopy to reveal if they are able to grow as mono- and/or dual-species biofilms. As far as we know, this is the first report on the ability to adhere and form mono/dual-species biofilms exhibited by strains belonging to the species Bacteroides oralis, Clostridium difficile, Clostridium baratii, Clostridium fallax, Clostridium bifermentans, Finegoldia magna, and Fusobacterium necrophorum. © 2012 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  19. The fate of methanol in anaerobic bioreactors

    NARCIS (Netherlands)

    Florencio, L.

    1994-01-01

    Methanol is an important component of certain industrial wastewaters. In anaerobic environments, methanol can be utilized by methanogens and acetogens. In wastewater treatment plants, the conversion of methanol into methane is preferred because this conversion is responsible for chemical

  20. The anaerobic treatment of sulfate containing wastewater

    NARCIS (Netherlands)

    Visser, A.

    1995-01-01


    In the anaerobic treatment of sulfate containing wastewater sulfate reducing bacteria (SRB) will compete with methanogenic- (MB) and acetogenic bacteria (AB) for the available substrates such as hydrogen, acetate, propionate and butyrate. The outcome of this competition will

  1. Anaerobic oxidation of methane and ammonium.

    NARCIS (Netherlands)

    Strous, M.; Jetten, M.S.M.

    2004-01-01

    Anaerobic oxidation of methane and ammonium are two different processes catalyzed by completely unrelated microorganisms. Still, the two processes do have many interesting aspects in common. First, both of them were once deemed biochemically impossible and nonexistent in nature, but have now been

  2. Anaerobic digestion of space mission wastes.

    Science.gov (United States)

    Chynoweth, D P; Owens, J M; Teixeira, A A; Pullammanappallil, P; Luniya, S S

    2006-01-01

    The technical feasibility of applying leachbed high-solids anaerobic digestion for reduction and stabilization of the organic fraction of solid wastes generated during space missions was investigated. This process has the advantages of not requiring oxygen or high temperature and pressure while producing methane, carbon dioxide, nutrients, and compost as valuable products. Anaerobic biochemical methane potential assays run on several waste feedstocks expected during space missions resulted in ultimate methane yields ranging from 0.23 to 0.30 L g-1 VS added. Modifications for operation of a leachbed anaerobic digestion process in space environments were incorporated into a new design, which included; (1) flooded operation to force leachate through densified feedstock beds; and (2) separation of biogas from leachate in a gas collection reservoir. This mode of operation resulted in stable performance with 85% conversion of a typical space solid waste blend, and a methane yield of 0.3 Lg per g VS added after a retention time of 15 days. These results were reproduced in a full-scale prototype system. A detailed analysis of this process was conducted to design the system sized for a space mission with a six-person crew. Anaerobic digestion compared favorably with other technologies for solid waste stabilization.

  3. Potential for anaerobic conversion of xenobiotics

    DEFF Research Database (Denmark)

    Mogensen, Anders Skibsted; Dolfing, J.; Haagensen, Frank

    2003-01-01

    regarding the treatment of xenobiotics is shown with the focus on the UASB reactor, but the applicability of other reactor designs for treatment of hazardous waste is also included. Bioaugmentation has proved to be a viable technique to enhance a specific activity in anaerobic reactors and recent research...... on reactor and in situ bioaugmentation is reported....

  4. Anaerobic Digestion in a Flooded Densified Leachbed

    Science.gov (United States)

    Chynoweth, David P.; Teixeira, Arthur A.; Owens, John M.; Haley, Patrick J.

    2009-01-01

    A document discusses the adaptation of a patented biomass-digesting process, denoted sequential batch anaerobic composting (SEBAC), to recycling of wastes aboard a spacecraft. In SEBAC, high-solids-content biomass wastes are converted into methane, carbon dioxide, and compost.

  5. Anaerobic Toxicity of Cationic Silver Nanoparticles

    Science.gov (United States)

    The microbial toxicity of silver nanoparticles (AgNPs) stabilized with different capping agents was compared to that of Ag+ under anaerobic conditions. Three AgNPs were investigated: (1) negatively charged citrate-coated AgNPs (citrate-AgNPs), (2) minimally charged p...

  6. Anaerobic prefermentation and primary sedimentation of wastewater ...

    African Journals Online (AJOL)

    This research was carried out with the aim of evaluating the solubilisation and acidification capacity of fermenting organisms in suspension in a sequencing batch reactor (SBR), which had a volume of 1 800 ℓ. Using 8 h cycles with 340 min of anaerobic reaction time, the wastewater fed to the SBR presented an average of ...

  7. Sulfate-reducing bacteria in anaerobic bioreactors

    NARCIS (Netherlands)

    Oude Elferink, S.J.W.H.

    1998-01-01

    The treatment of industrial wastewaters containing high amounts of easily degradable organic compounds in anaerobic bioreactors is a well-established process. Similarly, wastewaters which in addition to organic compounds also contain sulfate can be treated in this way. For a long time, the

  8. Essential metal depletion in an anaerobic reactor

    NARCIS (Netherlands)

    Osuna, M.B.; Iza, J.M.; Zandvoort, M.H.; Lens, P.N.L.

    2003-01-01

    The effect of the absence of trace elements on the conversion of a mixture of volatile fatty acids by a distillery anaerobic granular sludge was investigated. Two UASB reactors were operated under identical operational conditions except for the influent trace metal concentrations, during 140 days.

  9. Anaerobic Benzene Oxidation by Geobacter Species

    Science.gov (United States)

    Bain, Timothy S.; Nevin, Kelly P.; Barlett, Melissa A.; Lovley, Derek R.

    2012-01-01

    The abundance of Geobacter species in contaminated aquifers in which benzene is anaerobically degraded has led to the suggestion that some Geobacter species might be capable of anaerobic benzene degradation, but this has never been documented. A strain of Geobacter, designated strain Ben, was isolated from sediments from the Fe(III)-reducing zone of a petroleum-contaminated aquifer in which there was significant capacity for anaerobic benzene oxidation. Strain Ben grew in a medium with benzene as the sole electron donor and Fe(III) oxide as the sole electron acceptor. Furthermore, additional evaluation of Geobacter metallireducens demonstrated that it could also grow in benzene-Fe(III) medium. In both strain Ben and G. metallireducens the stoichiometry of benzene metabolism and Fe(III) reduction was consistent with the oxidation of benzene to carbon dioxide with Fe(III) serving as the sole electron acceptor. With benzene as the electron donor, and Fe(III) oxide (strain Ben) or Fe(III) citrate (G. metallireducens) as the electron acceptor, the cell yields of strain Ben and G. metallireducens were 3.2 × 109 and 8.4 × 109 cells/mmol of Fe(III) reduced, respectively. Strain Ben also oxidized benzene with anthraquinone-2,6-disulfonate (AQDS) as the sole electron acceptor with cell yields of 5.9 × 109 cells/mmol of AQDS reduced. Strain Ben serves as model organism for the study of anaerobic benzene metabolism in petroleum-contaminated aquifers, and G. metallireducens is the first anaerobic benzene-degrading organism that can be genetically manipulated. PMID:23001648

  10. Effect of methanogenic substrates on anaerobic oxidation of methane and sulfate reduction by an anaerobic methanotrophic enrichment.

    KAUST Repository

    Meulepas, Roel J W

    2010-05-06

    Anaerobic oxidation of methane (AOM) coupled to sulfate reduction (SR) is assumed to be a syntrophic process, in which methanotrophic archaea produce an interspecies electron carrier (IEC), which is subsequently utilized by sulfate-reducing bacteria. In this paper, six methanogenic substrates are tested as candidate-IECs by assessing their effect on AOM and SR by an anaerobic methanotrophic enrichment. The presence of acetate, formate or hydrogen enhanced SR, but did not inhibit AOM, nor did these substrates trigger methanogenesis. Carbon monoxide also enhanced SR but slightly inhibited AOM. Methanol did not enhance SR nor did it inhibit AOM, and methanethiol inhibited both SR and AOM completely. Subsequently, it was calculated at which candidate-IEC concentrations no more Gibbs free energy can be conserved from their production from methane at the applied conditions. These concentrations were at least 1,000 times lower can the final candidate-IEC concentration in the bulk liquid. Therefore, the tested candidate-IECs could not have been produced from methane during the incubations. Hence, acetate, formate, methanol, carbon monoxide, and hydrogen can be excluded as sole IEC in AOM coupled to SR. Methanethiol did inhibit AOM and can therefore not be excluded as IEC by this study.

  11. Anaerobic digestion of biowastes; Biojaetteen anaerobinen hajottaminen

    Energy Technology Data Exchange (ETDEWEB)

    Kymaelaeinen, M. [Haeme Polytechnic, Haemeenlinna (Finland)

    2005-07-01

    Caused by the demand for potential treatment options for biowastes, an interest on anaerobic digestion (AD) technology, i.e. biogasification, has clearly being increasing in Finland. There has been a need to increase knowledge and offer research facilities for the companies and other parties concerned. In this project, first, research and analytical facilities for AD studies were set up and tested. A mixture of a nitrogen rich waste (poultry slaughterhouse waste, PSHW) and a carbon rich waste (modified potato starch waste, PSW) was selected for the codigestion studies with sewage sludge (SS). The codigestion was studied in thermophilic lab-scale digesters (2x10 and 30 liters), and the startup of thermophilic digestion was clarified, in general. Typically, the PSHW must be treated at low load and long retention time due to the high concentration of lipids and proteins and their potential toxic degradation products such as long-chained fatty acids (LCFAs) and ammonia. The codigestion can help in lowering the effects of these toxic compounds. In this work, based on the experiments in 10 liters reactors fed with a fixed mixture of 2% PSHW, 8% PSW and 90% of SS, high loads of 2-4 kgVS/m3d and SRTs of 30 to 15 days could be applied. Good VS destruction could be achieved with 30 d SRT (76%) and 20 d SRT (55%). Based on the tests in 30 liters reactor fed with a varied mixture of the above mentioned wastes, high load of 4,8 kgVS/m{sup 3}d and SRT of 22 days with a mixture of 10% PSHW, 14% PSW and 76% of SS was also successfully applied. This resulted in the biogas production of about 0,7 Nm3/kgVSfed and VS reduction of around 70%. The critical process parameters were monitored in order to avoid the overloading of these digestion processes. The startup of thermophilic reactors with mesophilic digested sludge as inocula was successfully demonstrated. The findings increased the understanding and learned to control the startup and loading of AD processes thus encouraging the

  12. Determination of lactic and alactic metabolisms of the anaerobic capacity using oxygen uptake

    Directory of Open Access Journals (Sweden)

    Rodrigo Poles Urso

    2013-07-01

    Full Text Available It has been suggested that the participation of alactic anaerobic metabolism(AAM in physical activity can be estimated by calculating the fast componentof excess post-exercise oxygen consumption (EPOCFAST. Considering that maximalaccumulated oxygen deficit (MAOD represents the total amount of energytransferred by anaerobic metabolisms, this study aimed to analyze whethersubtracting EPOCFAST from MAOD (MAODLA-1 provides a satisfactory estimate oflactic anaerobic metabolism (LAM. For this purpose, MAODLA-1 was compared withthe method by which the energy derived from blood lactate accumulation (MAODLA-2is expressed as oxygen equivalent. Nine active adult men were submitted to fourexperimental sessions: 1 a maximal incremental exercise test until exhaustionon a cycle ergometer to measure the maximal oxygen consumption (VO2max and theexternal power corresponding to VO2max (WVO2max; 2 and 3 sixconstant-workload tests (3 per session at intensities below WVO2max; 4 oneconstant-workload test at an intensity corresponding to 110% of W O2max. Themain finding was that both methods (MAODLA-1 e MAODLA-2 that were used toestimate the contribution of LAM in MAOD resulted in similar statistical values(p > 0.05. In addition, percentage values of MAODLA-1 (representing MAL and EPOCFAST (representing AAM were approximately 78 and 22%, respectively. Thus,the procedure proposed in this paper may be of interest to future studies onthe contribution of anaerobic components to MAOD.

  13. Short bouts of anaerobic exercise increase non-esterified fatty acids release in obesity.

    Science.gov (United States)

    Salvadori, Alberto; Fanari, Paolo; Marzullo, Paolo; Codecasa, Franco; Tovaglieri, Ilaria; Cornacchia, Mauro; Brunani, Amelia; Luzi, Livio; Longhini, Erminio

    2014-02-01

    It is demonstrated that aerobic exercise plays an important role in weight loss programs for obesity by increasing 24 h metabolic rate. While aerobic exercise can result in health and fitness benefits in obese subjects, also independently of weight loss, not completely clear are the effects of bouts of hard exercise on metabolic outcomes. The aim of this study was to test the hypothesis that short-term aerobic activity with anaerobic bouts might result in a greater improvement in the management of obesity than aerobic activity alone. We studied 16 obese subjects (eight men) during a progressive cycloergometric test up to exhaustion, before and after 4 weeks of two different training schedules (6 days/week). Insulin and glycaemia, non-esterified fatty acids (NEFA) and lactic acid were sampled. Group A (eight subjects, four men) performed an aerobic cycle workout; Group B (eight subjects, four men) performed a 25 min aerobic workout followed by 5 min of anaerobic workout. All the subjects maintained their individual eating habits. The post-training test showed a decrease in AUCs NEFA in Group A (p anaerobic training seem to produce a greater response in lipid metabolism and not significant modifications in glucose indexes; then, in training prescription for obesity, we might suggest at starting weight loss program aerobic with short bouts of anaerobic training to reduce fat mass and subsequently a prolonged aerobic training alone to ameliorate the metabolic profile.

  14. Influence of upper-body external loading on anaerobic exercise performance.

    Science.gov (United States)

    Inacio, Mario; Dipietro, Loretta; Visek, Amanda J; Miller, Todd A

    2011-04-01

    The purpose of this study was to assess the threshold where simulated adipose tissue weight gain significantly affects performance in common anaerobic tasks and determine whether differences exist between men and women. Forty-six subjects (men = 21; women = 25) were tested for vertical jump, 20- and 40-yd dash, and 20-yd shuttle tests under 6 different loading conditions (0, 2, 4, 6, 8, and 10% of added body weight). Results were compared to each subject's baseline values (0% loading condition). Results demonstrate significant decrements in performance, starting at the 2% loading condition, for both genders, in every performance test (p anaerobic performance tests performed, increases in external loading as low as 2% of body weight results in significant decreases in performance. Moreover, for these specific tests, men and women tend to express the same threshold in performance decrements.

  15. Metabolic determinants in Listeria monocytogenes anaerobic listeriolysin O production.

    Science.gov (United States)

    Wallace, Nathan; Newton, Eric; Abrams, Elizabeth; Zani, Ashley; Sun, Yvonne

    2017-08-01

    Listeria monocytogenes is a human pathogen and a facultative anaerobe. To better understand how anaerobic growth affects L. monocytogenes pathogenesis, we first showed that anaerobic growth led to decreased growth and changes in surface morphology. Moreover, compared to aerobically grown bacteria, anaerobically grown L. monocytogenes established higher level of invasion but decreased intracellular growth and actin polymerization in cultured cells. The production of listeriolysin O (LLO) was significantly lower in anaerobic cultures-a phenotype observed in wild type and isogenic mutants lacking transcriptional regulators SigB or CodY or harboring a constitutively active PrfA. To explore potential regulatory mechanisms, we established that the addition of central carbon metabolism intermediates, such as acetate, citrate, fumarate, pyruvate, lactate, and succinate, led to an increase in LLO activity in the anaerobic culture supernatant. These results highlight the regulatory role of central carbon metabolism in L. monocytogenes pathogenesis under anaerobic conditions.

  16. Anaerobic and Aerobic Performances in Elite Basketball Players

    Directory of Open Access Journals (Sweden)

    Gomes de Araujo Gustavo

    2014-10-01

    Full Text Available The purpose of this study was to propose a specific lactate minimum test for elite basketball players considering the: Running Anaerobic Sprint Test (RAST as a hyperlactatemia inductor, short distances (specific distance, 20 m during progressive intensity and mathematical analysis to interpret aerobic and anaerobic variables. The basketball players were assigned to four groups: All positions (n=26, Guard (n= 7, Forward (n=11 and Center (n=8. The hyperlactatemia elevation (RAST method consisted of 6 maximum sprints over 35 m separated by 10 s of recovery. The progressive phase of the lactate minimum test consisted of 5 stages controlled by an electronic metronome (8.0, 9.0, 10.0, 11.0 and 12.0 km/h over a 20 m distance. The RAST variables and the lactate values were analyzed using visual and mathematical models. The intensity of the lactate minimum test, determined by a visual method, reduced in relation to polynomial fits (2nd degree for the Small Forward positions and General groups. The Power and Fatigue Index values, determined by both methods, visual and 3rd degree polynomial, were not significantly different between the groups. In conclusion, the RAST is an excellent hyperlactatemia inductor and the progressive intensity of lactate minimum test using short distances (20 m can be specifically used to evaluate the aerobic capacity of basketball players. In addition, no differences were observed between the visual and polynomial methods for RAST variables, but lactate minimum intensity was influenced by the method of analysis

  17. Changes in the antibiotic susceptibility of anaerobic bacteria from 2007-2009 to 2010-2012 based on the CLSI methodology.

    Science.gov (United States)

    Hastey, Christine J; Boyd, Halsey; Schuetz, Audrey N; Anderson, Karen; Citron, Diane M; Dzink-Fox, Jody; Hackel, Meredith; Hecht, David W; Jacobus, Nilda V; Jenkins, Stephen G; Karlsson, Maria; Knapp, Cynthia C; Koeth, Laura M; Wexler, Hannah; Roe-Carpenter, Darcie E

    2016-12-01

    Antimicrobial susceptibility testing of anaerobic isolates was conducted at four independent sites from 2010 to 2012 and compared to results from three sites during the period of 2007-2009. This data comparison shows significant changes in antimicrobial resistance in some anaerobic groups. Therefore, we continue to recommend institutions regularly perform susceptibility testing when anaerobes are cultured from pertinent sites. Annual generation of an institutional-specific antibiogram is recommended for tracking of resistance trends over time. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Test

    DEFF Research Database (Denmark)

    Bendixen, Carsten

    2014-01-01

    Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers.......Bidrag med en kortfattet, introducerende, perspektiverende og begrebsafklarende fremstilling af begrebet test i det pædagogiske univers....

  19. A quasi-universal medium to break the aerobic/anaerobic bacterial culture dichotomy in clinical microbiology.

    Science.gov (United States)

    Dione, N; Khelaifia, S; La Scola, B; Lagier, J C; Raoult, D

    2016-01-01

    In the mid-19th century, the dichotomy between aerobic and anaerobic bacteria was introduced. Nevertheless, the aerobic growth of strictly anaerobic bacterial species such as Ruminococcus gnavus and Fusobacterium necrophorum, in a culture medium containing antioxidants, was recently demonstrated. We tested aerobically the culture of 623 bacterial strains from 276 bacterial species including 82 strictly anaerobic, 154 facultative anaerobic, 31 aerobic and nine microaerophilic bacterial species as well as ten fungi. The basic culture medium was based on Schaedler agar supplemented with 1 g/L ascorbic acid and 0.1 g/L glutathione (R-medium). We successively optimized this media, adding 0.4 g/L uric acid, using separate autoclaving of the component, or adding haemin 0.1 g/L or α-ketoglutarate 2 g/L. In the basic medium, 237 bacterial species and ten fungal species grew but with no growth of 36 bacterial species, including 22 strict anaerobes. Adding uric acid allowed the growth of 14 further species including eight strict anaerobes, while separate autoclaving allowed the growth of all tested bacterial strains. To extend its potential use for fastidious bacteria, we added haemin for Haemophilus influenzae, Haemophilus parainfluenzae and Eikenella corrodens and α-ketoglutarate for Legionella pneumophila. This medium allowed the growth of all tested strains with the exception of Mycobacterium tuberculosis and Mycobacterium bovis. Testing primoculture and more fastidious species will constitute the main work to be done, but R-medium coupled with a rapid identification method (matrix-assisted laser desorption/ionization time-of-flight mass spectrometry) will facilitate the anaerobic culture in clinical microbiology laboratories. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Performance of sequential anaerobic/aerobic digestion applied to municipal sewage sludge.

    Science.gov (United States)

    Tomei, M Concetta; Rita, Sara; Mininni, Giuseppe

    2011-07-01

    A promising alternative to conventional single phase processing, the use of sequential anaerobic-aerobic digestion, was extensively investigated on municipal sewage sludge from a full scale wastewater treatment plant. The objective of the work was to evaluate sequential digestion performance by testing the characteristics of the digested sludge in terms of volatile solids (VS), Chemical Oxygen Demand (COD) and nitrogen reduction, biogas production, dewaterability and the content of proteins and polysaccharides. VS removal efficiencies of 32% in the anaerobic phase and 17% in the aerobic one were obtained, and similar COD removal efficiencies (29% anaerobic and 21% aerobic) were also observed. The aerobic stage was also efficient in nitrogen removal providing a decrease of the nitrogen content in the supernatant attributable to nitrification and simultaneous denitrification. Moreover, in the aerobic phase an additional marked removal of proteins and polysaccharides produced in the anaerobic phase was achieved. The sludge dewaterability was evaluated by determining the Optimal Polymer Dose (OPD) and the Capillary Suction Time (CST) and a significant positive effect due to the aerobic stage was observed. Biogas production was close to the upper limit of the range of values reported in the literature in spite of the low anaerobic sludge retention time of 15 days. From a preliminary analysis it was found that the energy demand of the aerobic phase was significantly lower than the recovered energy in the anaerobic phase and the associated additional cost was negligible in comparison to the saving derived from the reduced amount of sludge to be disposed. Copyright © 2011 Elsevier Ltd. All rights reserved.

  1. Methane Production of Full-Scale Anaerobic Digestion Plants Calculated from Substrate’s Biomethane Potentials Compares Well with the One Measured On-Site

    National Research Council Canada - National Science Library

    Christof Holliger; Hélène Fruteau de Laclos; Gabrielle Hack

    2017-01-01

    Biomethane potential (BMP) tests are used to determine the amount of methane that can be produced from organic materials in order to design different components of full-scale anaerobic digestion (AD...

  2. Anaerobic ammonia oxidation in a fertilized paddy soil

    DEFF Research Database (Denmark)

    Zhu, Guibing; Wang, Shanyun; Wang, Yu

    2011-01-01

    Evidence for anaerobic ammonium oxidation in a paddy field was obtained in Southern China using an isotope-pairing technique, quantitative PCR assays and 16S rRNA gene clone libraries, along with nutrient profiles of soil cores. A paddy field with a high load of slurry manure as fertilizer...... was selected for this study and was shown to contain a high amount of ammonium (6.2–178.8 mg kg−1). The anaerobic oxidation of ammonium (anammox) rates in this paddy soil ranged between 0.5 and 2.9 nmolN per gram of soil per hour in different depths of the soil core, and the specific cellular anammox activity...... observed in batch tests ranged from 2.9 to 21 fmol per cell per day. Anammox contributed 4–37% to soil N2 production, the remainder being due to denitrification. The 16S rRNA gene sequences of surface soil were closely related to the anammox bacteria ‘Kuenenia’, ‘Anammoxoglobus’ and ‘Jettenia’. Most...

  3. Treatment of separated piggery anaerobic digestate liquid using woodchip biofilters.

    Science.gov (United States)

    Carney, K N; Rodgers, M; Lawlor, P G; Zhan, X

    2013-01-01

    The Irish nitrates directive restricts the land area suitable for landspreading of pig manure, so anaerobic digestion warrants consideration. In this study, six identical Lodgepole pine woodchip biofilters were set up to treat the separated liquid fraction of digestate after anaerobic digestion of pig manure. Two hydraulic loading rates were examined: 5 L/m2/d (LLR) and 10 L/m2/d (HLR). Following a start-up period of 70 days, an average of 90% and 71% of NH4(+)-N was removed at LLR and HLR, respectively. LLR resulted in higher total nitrogen removals than HLR (p < 0.05). Efficient nitrification occurred at LLR as indicated by the lower NH4(+)-N (p < 0.05) and higher NO3(-)-N (p < 0.05) concentrations in the biofilter effluent. A batch experiment testing the capacity of saturated woodchips in removing total oxidized nitrogen (TON) from the effluent of the woodchip biofilters showed that TON was reduced by 323 mg/L from 663 mg/L in 360 h, indicating that the aerobic woodchip biofilters should incorporate a saturated layer ofwoodchips at the base ofthe biofilters to enhance nitrogen removal.

  4. Anaerobic digestion and co-digestion of slaughterhouse wastes

    Directory of Open Access Journals (Sweden)

    Sonia Castellucci

    2013-09-01

    Full Text Available The use of renewable energy is becoming increasingly necessary in order to address the global warming problem and, as a consequence, has become an high priority for many countries. Biomass is a clean and renewable energy source with growing potential to replace conventional fossil fuels. Among biomass, residual and waste ones represent a great resource for energy generation since they permit both to eliminate a possible waste and to produce energy. In the present work, the case of slaughterhouse wastes (SHWs has been investigated. Anaerobic digestion is nowadays considered as one of the most important and sustainable conversion technology exploiting organic matter and biodegradable wastes. Biogas results from this bio-chemical process and mainly consists of methane and carbon dioxide, leading to produce thermal energy and/or electricity. In this paper, the European Regulations on animal by-products (ABPs are described, and some previous study on anaerobic digestion and co-digestion of ABPs - more precisely SHWs - are considered and compared in order to fix a starting point for future tests on their co-digestion in a micro-scale pilot digester. This is to define optimal feed ratio values which ensure an increasing content of methane in the outgoing biogas.

  5. Anaerobic Digestion of Buffalo Dung: Simulation of Process Kinetics

    Directory of Open Access Journals (Sweden)

    Abdul Razaque Sahito

    2015-01-01

    Full Text Available Assessment of kinetic of AD (Anaerobic Digestion is a beneficial practice to forecast the performance of the process. It is helpful in the design of AD vessels, substrate feeding and digestate exit systems. The aim of this work was to assess the kinetics of anaerobically digested buffalo dung at different quantities of water added. It comprises the assessment of the specific methane production on the basis of VS (Volatile Solids added in each reactor by using three first order models, i.e. the modified Gompertz model, the Cone model and the Exponential Curve Factor model. The analysis was tested by using the three statistical parameters, i.e. the coefficient of multiple determinations, the standard deviation of residuals and the Akaike?s Information Criteria. The result reveals that the Exponential Curve Factor model was the best model that described the experimental data well. Moreover, there was not a direct or indirect relation between the kinetic coefficients of the AD process with the varying total or volatile solid content

  6. Anaerobic biogranulation using phenol as the sole carbon source

    Energy Technology Data Exchange (ETDEWEB)

    Tay, J.H.; He, Y.X.; Yan, Y.G.

    2000-04-01

    The granulation process was extensively examined using phenol as sole carbon source in a 2-L laboratory upflow anaerobic sludge blanket (UASB) reactor. The study was conducted mesophilically at 35 C. Anaerobically digested sludge was used as seed after a 14-day activation period with glucose feed. Massive initial granules were developed after 3 months of startup, grew at an accelerated pace for 6 months, then became fully grown. The granulation process can be broken into three phases: acclimation, granulation, and maturation. However, granulation with phenol proceeded more slowly than it did in UASB reactors fed with readily biodegradable carbohydrates studied previously. The granular sludge cultivated had a median diameter of 1.8 mm, phenol-degrading activity of 0.65 g chemical oxygen demand (COD)/g volatile suspended solids (VSS){sm_bullet}d, and a sludge volume index of 14 mL/g. Phenol COD removal efficiency of 86% was achieved when the reactor was operating at an influent phenol concentration of 1,260 mg/L (corresponding to 3,000 mg COD/L), hydraulic retention time of 12 hours, and volumetric loading rate of 6 g COD/L{sm_bullet}d. However, the lower-than-expected phenol COD removal efficiency could be attributed to inhibition by the high influent phenol concentration or loading. The batch test demonstrated that the sludge methanogenic activity was reduced by 52 and 75% at phenol concentrations of 420 and 840 mg/L, respectively.

  7. Alkali-assisted membrane cleaning for fouling control of anaerobic ceramic membrane bioreactor.

    Science.gov (United States)

    Mei, Xiaojie; Quek, Pei Jun; Wang, Zhiwei; Ng, How Yong

    2017-09-01

    In this study, a chemically enhanced backflush (CEB) cleaning method using NaOH solution was proposed for fouling mitigation in anaerobic membrane bioreactors (AnMBRs). Ex-situ cleaning tests revealed that NaOH dosages ranging from 0.05 to 1.30mmol/L had positive impacts on anaerobic biomass, while higher dosages (>1.30mmol/L) showed inhibition and/or toxic impacts. In-situ cleaning tests showed that anaerobic biomass could tolerate much higher NaOH concentrations due to the alkali consumption by anaerobic process and/or the buffering role of mixed liquor. More importantly, 10-20mmol-NaOH/L could significantly reduce membrane fouling rates (4-5.5 times over the AnMBR with deionized water backflush) and slightly improve methanogenic activities. COD removal efficiencies were over 87% and peaked at 20mmol-NaOH/L. However, extremely high NaOH concentration had adverse effects on filtration and treatment performance. Economic analysis indicated that 12mmol/L of NaOH was the cost-efficient and optimal fouling-control dosage for the CEB cleaning. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Anaerobic capacity in soccer players from different competitive levels: Comparison of players in different field positions

    Directory of Open Access Journals (Sweden)

    Vanderson Luis Moro

    2012-10-01

    Full Text Available The aim of this study was to compare anaerobic capacity in professional soccer players of different competitive levels in their respective positions in the game, early in the preseason. The study group consisted of 44 male athletes belonging to two groups (A and B of different competitive levels. Group A was composed of 20 athletes participating in the Sagres League - Portuguese. Group B was composed of 24 athletes participating in the 2nd division Championship Gaucho - Brazil. For the assessment of anaerobic capacity it was applied the Running-based Anaerobic Sprint Test - RAST. For data analysis it was used the Student t test for independent samples and analysis of variance (ANOVA One Way supplemented with post hoc Tukey. Results showed that group A athletes performed better on the average power and worst values for the fatigue index. In the group A it was found statistical difference between attacks and other two positions (midfielder and side back for the fatigue index. It is concluded that there was significant differences in anaerobic capacity, measured at the start of the preseason, evaluated soccer players who work in competitions of different levels and positions play (group A.

  9. Anaerobic Exercise Affects the Saliva Antioxidant/Oxidant Balance in High-Performance Pentathlon Athletes

    Directory of Open Access Journals (Sweden)

    Sant’Anna Marcelo de Lima

    2016-03-01

    Full Text Available Purpose. Investigate free radical production and antioxidant buffering in military pentathletes’ saliva after their performance of a standardized, running-based anaerobic sprint test (RAST. Methods. Seven members of the Brazilian Navy pentathlon team were recruited to perform a running-based anaerobic test (~90 sec. The participants provided samples of saliva before and after the test that were analyzed for biomarkers of oxidative stress such as lipid peroxidation, total antioxidant capacity and the quantity of two specific antioxidants, glutathione and uric acid. Results. The lipid peroxidation increased ~2 fold after RAST, despite an increase in total antioxidant capacity (46%. The concentration of reduced glutathione did not change, while the uric acid concentration increased by 65%. Conclusions. The evaluation in saliva following a sprint test that lasted no more than 90 sec was sensitive enough to reveal changes in redox state.

  10. Non spirographic or noninvasive methods to estimate anaerobic treshold

    Directory of Open Access Journals (Sweden)

    Najera-Longoria Raul Hose

    2017-01-01

    Full Text Available In the world of sports research, there are different ways to determinate physical conditioning, ranging from expensive laboratory-invasive methods to cheap, field based-non-invasive methods. The field based-non-invasive test maintains good reliability and low cost using physiological parameters such heart rate, saliva electrolytes or lactate, perceived exertion and electromyography among others. These parameters can be used to estimate anaerobic threshold (AnT to predict sport performance, redirect training and can help coaches and athletes to be more competitive. However, each of this parameter has some particularities and controversy due to different results reported by specialist. These differences may be explained by protocol testing used, sport level sample, starting intensity or number of levels among others. Despite this, they still have good reproducibility and applications on field based test protocols. Mentioned tests could be used in a large scale, and more often, with paying attention about level of correlation with original invasive tests, and percent of possible mistake in estimation process. Cheaper, and simpler tests (instead subjective estimation of training load allows using more precise planning and changing volume, and intensity of training, for coaches, and athletes, that have needed level of education and less money. Athletes comfort, and possible high frequency of testing during non - invasive test, also must be emphasized as an advantage during training evaluation process.

  11. Anaerobic Digestion: Mass Balances and Products

    DEFF Research Database (Denmark)

    Møller, Jacob; Christensen, Thomas Højlund; Jansen, Jes la Cour

    2011-01-01

    While the basic processes involved in anaerobic digestion of waste are described in Chapter 9.4 and the main digestion technologies are presented in Chapter 9.5, this chapter focuses on mass balances, gas production and energy aspects, environmental emissions and unit process inventories....... Understanding these issues and being able to account for them is a prerequisite in digestion engineering and for establishing and running a successful anaerobic digestion facility. Of specific importance is the final use of the digestate. Use in agriculture as a fertilizer is described in Chapter 9.10 and use...... after composting of the digestate as a soil amendment product is analogous to issues presented in Chapter 9.9 for compost....

  12. Instrumentation and Control in Anaerobic Digestion

    DEFF Research Database (Denmark)

    Anaerobic digestion is a multistep process, and is most applied to solids destruction and wastewater treatment for energy production. Despite wide application, and long-term industrial proof of application, some industries are still reluctant to apply this technology. One of the classical reasons...... benchmark. There has therefore been, overall, a quantum advance in application and sophistication of instrumentation and control in anaerobic digestion, and it is an effective option for improved process loading rate and conversion efficiency....... are still a limitation, but this is being partly addressed by the increased complexity of digestion processes. Methods for control benchmarking have also been improved, as there is now an industry standard model (the IWA ADM1), and this is being applied in an improved whole wastewater treatment plant...

  13. Atrazine removal in Danish anaerobic aquifers

    DEFF Research Database (Denmark)

    Pedersen, Philip Grinder; Arildskov, N.P.; Albrechtsen, Hans-Jørgen

    2002-01-01

    The pesticide atrazine (6-chloro-N-2-ethyl-N-4-isopropyl-1,3,5-triazine -2,4-diamine) was removed from the water phase in anaerobic laboratory batch incubations with sediment and groundwater from a number of Danish anaerobic aquifers, but not in incubations from aerobic aquifers. The removal...... process was abiotic since atrazine was also removed from microbially inhibited autoclaved and chloroform amended controls, although in controls amended with mercury, atrazine removal was slowed down. (ring-U-C-14)- atrazine amended samples showed no mineralization to (CO2)-C-14 or transformation...... to soluble degradation products, indicating that a slow sorption process was responsible for the atrazine removal. Approximately 20% of the applied C-14-atrazine was present in a non-extractable residual sediment bound fraction, indicating the slow sorption process to be in part irreversible...

  14. Anaerobic digestion trials with HTC process water

    OpenAIRE

    Nilsson, Erik

    2017-01-01

    Hydrothermal carbonization (HTC) is a process where elevated temperature and pressure is used in order to convert biomass to hydrochar, a coal-like substance with good dewatering properties and many potential uses. HTC can be used to treat digestate from anaerobic digestion, but the process water that remains after the hydrochar has been recovered needs to be treated further in the wastewater treatment plant. In order to make HTC more competitive compared to other sludge treatments it is impo...

  15. Monitoring and control of anaerobic reactors

    DEFF Research Database (Denmark)

    Pind, Peter Frode; Angelidaki, Irini; Ahring, Birgitte Kiær

    2003-01-01

    The current status in monitoring and control of anaerobic reactors is reviewed. The influence of reactor design and waste composition on the possible monitoring and control schemes is examined. After defining the overall control structure, and possible control objectives, the possible process mea...... control approaches that have been used are comprehensively described. These include simple and adaptive controllers, as well as more recent developments such as fuzzy controllers, knowledge-based controllers and controllers based on neural networks....

  16. Polyamines and Anaerobic Elongation of Rice Coleoptile

    OpenAIRE

    Remo, Reggiani; Alejandro, Hochkoeppler; Alcide, Bertani; Istituto Biosintesi Vegetali, C. N. R.; Istituto Biosintesi Vegetali, C. N. R.; Istituto Biosintesi Vegetali, C. N. R.

    1989-01-01

    The role of polyamines in the anaerobic elongation of rice (Oryza sativa L.) coleoptiles was studied. The reduced growth of rice coleoptiles under anoxic conditions was accompanied by a massive accumulation of free putrescine. Putrescine was synthesized from arginine in a reaction catalyzed by arginine decarboxylase (ADC). The anoxic titer of putrescine was closely correlated with elongation of coleoptiles. In experiments in which putrescine and inhibitors [a-difluoromethylarginine (DFMA) and...

  17. Maximizing biogas production from the anaerobic digestion

    OpenAIRE

    Ghouali, Amel; Sari, Tewfik; Harmand, Jérôme

    2015-01-01

    Sous presse; International audience; This paper presents an optimal control law policy for maximizing biogas pro-duction of anaerobic digesters. In particular, using a simple model of the anaerobicdigestion process, we derive a control law to maximize the biogas production overa period T using the dilution rate as the control variable. Depending on initialconditions and constraints on the actuator (the dilution rate D(:)), the search fora solution to the optimal control problem reveals very d...

  18. Mastoiditis and Gradenigo's Syndrome with anaerobic bacteria.

    Science.gov (United States)

    Jacobsen, Chris Ladefoged; Bruhn, Mikkel Attermann; Yavarian, Yousef; Gaihede, Michael L

    2012-09-14

    Gradenigo's syndrome is a rare disease, which is characterized by the triad of the following conditions: suppurative otitis media, pain in the distribution of the first and the second division of trigeminal nerve, and abducens nerve palsy. The full triad may often not be present, but can develop if the condition is not treated correctly. We report a case of a 3-year-old girl, who presented with fever and left-sided acute otitis media. She developed acute mastoiditis, which was initially treated by intravenous antibiotics, ventilation tube insertion and cortical mastoidectomy. After 6 days the clinical picture was complicated by development of left-sided abducens palsy. MRI-scanning showed osteomyelitis within the petro-mastoid complex, and a hyper intense signal of the adjacent meninges. Microbiological investigations showed Staphylococcus aureus and Fusobacterium necrophorum. She was treated successfully with intravenous broad-spectrum antibiotic therapy with anaerobic coverage. After 8 weeks of follow-up there was no sign of recurrent infection or abducens palsy. Gradenigo's syndrome is a rare, but life-threatening complication to middle ear infection. It is most commonly caused by aerobic microorganisms, but anaerobic microorganisms may also be found why anaerobic coverage should be considered when determining the antibiotic treatment.

  19. Unravelling carbon metabolism in anaerobic cellulolytic bacteria.

    Science.gov (United States)

    Desvaux, Mickaël

    2006-01-01

    Carbon metabolism in anaerobic cellulolytic bacteria has been investigated essentially in Clostridium thermocellum, Clostridium cellulolyticum, Fibrobacter succinogenes, Ruminococcus flavefaciens, and Ruminococcus albus. While cellulose depolymerization into soluble sugars by various cellulases is undoubtedly the first step in bacterial metabolisation of cellulose, it is not the only one to consider. Among anaerobic cellulolytic bacteria, C. cellulolyticum has been investigated metabolically the most in the past few years. Summarizing metabolic flux analyses in continuous culture using either cellobiose (a soluble cellodextrin resulting from cellulose hydrolysis) or cellulose (an insoluble biopolymer), this review aims to stress the importance of the insoluble nature of a carbon source on bacterial metabolism. Furthermore, some general and specific traits of anaerobic cellulolytic bacteria trends, namely, the importance and benefits of (i) cellodextrins with degree of polymerization higher than 2, (ii) intracellular phosphorolytic cleavage, (iii) glycogen cycling on cell bioenergetics, and (iv) carbon overflows in regulation of carbon metabolism, as well as detrimental effects of (i) soluble sugars and (ii) acidic environment on bacterial growth. Future directions for improving bacterial cellulose degradation are discussed.

  20. Relationship between anaerobic capacity estimated using a single effort and 30-s tethered running outcomes.

    Science.gov (United States)

    Zagatto, Alessandro Moura; Miyagi, Willian Eiji; Sousa, Filipe Antônio de Barros; Gobatto, Claudio Alexandre

    2017-01-01

    The purpose of the current study was to investigate the relationship between alternative anaerobic capacity method (MAODALT) and a 30-s all-out tethered running test. Fourteen male recreational endurance runners underwent a graded exercise test, a supramaximal exhaustive effort and a 30-s all-out test on different days, interspaced by 48h. After verification of data normality (Shapiro-Wilk test), the Pearson's correlation test was used to verify the association between the anaerobic estimates from the MAODALT and the 30-s all-out tethered running outputs. Absolute MAODALT was correlated with mean power (r = 0.58; P = 0.03), total work (r = 0.57; P = 0.03), and mean force (r = 0.79; P = 0.001). In addition, energy from the glycolytic pathway (E[La-]) was correlated with mean power (r = 0.58; P = 0.03). Significant correlations were also found at each 5s interval between absolute MAODALT and force values (r between 0.75 and 0.84), and between force values and E[La-] (r between 0.73 to 0.80). In conclusion, the associations between absolute MAODALT and the mechanical outputs from the 30-s all-out tethered running test evidenced the importance of the anaerobic capacity for maintaining force during the course of time in short efforts.

  1. Relationship between anaerobic capacity estimated using a single effort and 30-s tethered running outcomes.

    Directory of Open Access Journals (Sweden)

    Alessandro Moura Zagatto

    Full Text Available The purpose of the current study was to investigate the relationship between alternative anaerobic capacity method (MAODALT and a 30-s all-out tethered running test. Fourteen male recreational endurance runners underwent a graded exercise test, a supramaximal exhaustive effort and a 30-s all-out test on different days, interspaced by 48h. After verification of data normality (Shapiro-Wilk test, the Pearson's correlation test was used to verify the association between the anaerobic estimates from the MAODALT and the 30-s all-out tethered running outputs. Absolute MAODALT was correlated with mean power (r = 0.58; P = 0.03, total work (r = 0.57; P = 0.03, and mean force (r = 0.79; P = 0.001. In addition, energy from the glycolytic pathway (E[La-] was correlated with mean power (r = 0.58; P = 0.03. Significant correlations were also found at each 5s interval between absolute MAODALT and force values (r between 0.75 and 0.84, and between force values and E[La-] (r between 0.73 to 0.80. In conclusion, the associations between absolute MAODALT and the mechanical outputs from the 30-s all-out tethered running test evidenced the importance of the anaerobic capacity for maintaining force during the course of time in short efforts.

  2. Estudo comparativo do consumo de oxigênio e limiar anaeróbio em um teste de esforço progressivo entre atletas profissionais de futebol e futsal Estudio comparativo del consumo de oxígeno y límite anaeróbico en un test de esfuerzo progresivo entre atletas profesionales de fútbol y fútbol de salón Comparative study of the oxygen consumption and anaerobic threshold in a progressive exertion test in professional soccer and indoor soccer athletes

    Directory of Open Access Journals (Sweden)

    Ernesto Cesar Pinto Leal Junior

    2006-12-01

    progresivo. Participaron voluntariamente 31 individuos del sexo masculino, entre ellos: 19 atletas profesionales de fútbol, y 12 atletas profesionales de fútbol de salón. Los deportistas fueron sometidos a un protocolo de evaluación cardiorrespiratoria progresiva por el método ergoespirométrico, y os resultados fueron analizados en relación a su diferencia estadística a través del test t-Student (p 0,05; a pesar de eso hubo diferencia estadística entre los dos grupos en relación al límite anaeróbico (LA (p Oxygen consumption (VO2 has been very useful for the functional evaluation of athletes. Ergospirometry is a non-invasive procedure used to evaluate the physical performance or the functional ability of an individual, connecting the analysis of the inspired gases with the respiratory variables. This evaluation method is extremely important to sports, since it brings significant contribution in the verification of indices of cardiorespiratory aptitude, which is the case f the maximal oxygen consumption (VO2 max and the anaerobic threshold (AT. The present study had as objective to compare oxygen consumption and anaerobic threshold in professional soccer and indoor soccer athletes in a progressive test. 31 male individuals voluntarily participated in the test, being: 19 professional soccer athletes and 12 professional indoor soccer athletes. The athletes were submitted to a progressive cardiorespiratory evaluation protocol through the ergospirometric method, and the results were analyzed concerning their statistical difference through the t-Student test (p 0,05; however, there was statistically difference between the two groups concerning the anaerobic threshold (AT (p < 0,05. Based on the results obtained in our study we concluded that even practicing sports with different characteristics, the athletes from both groups have similar indices of oxygen consumption. Nevertheless, the anaerobic threshold between the two groups did not present the same similarity

  3. Aerobic and anaerobic cellulase production by Cellulomonas uda.

    Science.gov (United States)

    Poulsen, Henrik Vestergaard; Willink, Fillip Wolfgang; Ingvorsen, Kjeld

    2016-10-01

    Cellulomonas uda (DSM 20108/ATCC 21399) is one of the few described cellulolytic facultative anaerobes. Based on these characteristics, we initiated a physiological study of C. uda with the aim to exploit it for cellulase production in simple bioreactors with no or sporadic aeration. Growth, cellulase activity and fermentation product formation were evaluated in different media under both aerobic and anaerobic conditions and in experiments where C. uda was exposed to alternating aerobic/anaerobic growth conditions. Here we show that C. uda behaves as a true facultative anaerobe when cultivated on soluble substrates such as glucose and cellobiose, but for reasons unknown cellulase activity is only induced under aerobic conditions on insoluble cellulosic substrates and not under anaerobic conditions. These findings enhance knowledge on the limited number of described facultative cellulolytic anaerobes, and in addition it greatly limits the utility of C. uda as an 'easy to handle' cellulase producer with low aeration demands.

  4. Renewable Biochemical Methane Potential through Anaerobic Co-digestion from Selective Feed Stocks

    Science.gov (United States)

    Thara, K.; Navis Karthika, Ignatius; Dheenadayalan, M. S., Dr

    2017-08-01

    Biochemical Methane Potential (BMP) analysis provides a measure of the anaerobic biodegradability of a given substrate. BMP test is also used to evaluate the potential biogas (methane) production between various Co-digestion substrates. This test is also used to determine the amount of organic carbon in a given material that can be an aerobically converted to methane-Biogas. Studies were carried out for the production of biogas from the leather solid waste. Co-digestion (simultaneous digestion of two or more substrates) studies were carried out in batch reactor using the fleshing (a solid waste generated during the processing of raw hides or skins into finished leather) along with the fruit and vegetable waste at mesophilic condition 35° C). The anaerobic methanogenic seed sludge prepared separately followed by standard BMP test, which was used as the seed inoculums. Recent research on this topic is reviewed in this current paper.

  5. Status anaerobic energy sprinters qualified for the effects of a means of rehabilitation

    Directory of Open Access Journals (Sweden)

    Andriy Yefremenko

    2014-07-01

    Full Text Available Purpose: we determined the effect of the complex on the functional recovery of the state and dynamics of special physical qualities sprinters. Material and methods: the study involved 15 trained sprinters. Power anaerobic muscular activity was assessed using the battery of tests known. We have determined the ability of muscles, which reflects the potential for the rapid mobilization of productive resources systems sprinters. Results: dynamics of the special physical readiness test for the autumn-winter preparation period was positive and was at a high level, which was the key to improving athletic performance in a group of runners, sprinters, which was tested. Conclusions: revealed that the proposed complex of recovery has led to the growth rates of the special physical preparedness and capacity anaerobic power.

  6. A bio-electrochemical system for removing inhibitors of anaerobic digestion processes from anaerobic reactors

    DEFF Research Database (Denmark)

    2014-01-01

    Inhibition of anaerobic digestion process by high level of ammonia (NH4 +/I\\IH3) is the most serious problem existing in biogas plants. No viable/applicable method to overcome this problem has been found up to now. This invention proposes an innovative submersible bio-electrochemical membrane...... reactor to recover ammonia from anaerobic digestion reactor, and thereby alleviate or counteract ammonia inhibition and enhance the conversion of ammonia-rich wastes to biogas. The invention may further reduce overall cost, giving synergistic advantages for both ammonia recycling and biogas plants...

  7. Energy production by anaerobic treatment of cheese whey

    Energy Technology Data Exchange (ETDEWEB)

    Peano, L.; Ciciarelli, R.; Comino, E.; Gard, P. A.

    2009-07-01

    Anaerobic treatment and methane generation potential of cheese whey, diluted with mud, were determined in the digester of an existing wastewater treatment plant in Switzerland. Lactose, main sugar in cheese whey, can be a useful indicator to evaluate serum anaerobic treatment. Conventional parameters of anaerobic digestion (Volatile Matter, Dry Matter, Fatty Volatile Acids, total Alkali metric Title) were measured after the introduction of different whey/sludge ratio demonstrating that, despite an overcharge of whey digester, its stability is never compromised. (Author)

  8. Role of anaerobic bacteria in simian enteric diseases.

    Science.gov (United States)

    Stasilevich, Z K; Dzhikidze, E K; Kalashnikova, V A; Sultanova, O A

    2013-12-01

    Screening of monkeys for anaerobic bacteria showed that the incidence of non-spore-forming anaerobes was 2.0-2.5 times higher than that of clostridia. The overwhelming majority of isolated anaerobes were saprophytes and opportunistic bacteria. The incidence of C. perfringens was higher in monkeys with enteric infections of obscure etiology and dead from these diseases than in healthy animals (48.2 vs. 36.8%).

  9. Dissimilatory reduction of inorganic sulfur by facultatively anaerobic marine bacteria.

    Science.gov (United States)

    Tuttle, J H; Jannasch, H W

    1973-09-01

    THREE STRAINS, SELECTED FROM A LARGE NUMBER OF NEWLY ISOLATED, FACULTATIVELY ANAEROBIC MARINE BACTERIA, REDUCED INORGANIC SULFUR COMPOUNDS OTHER THAN SULFATE ANAEROBICALLY IN DEFINED CULTURE MEDIA IN THE FOLLOWING DIFFERENT PATTERNS: (i) sulfite and thiosulfate were reduced to sulfide, and tetrathionate was reduced to thiosulfate; (ii) tetrathionate was reduced to thiosulfate only; or (iii) thiosulfate was reduced to sulfide only when pyruvate was the substrate. Comparison of anaerobic growth in the presence or absence of inorganic sulfur compounds indicated true dissimilatory reductions.

  10. ANAEROBIC DIGESTION AND THE DENITRIFICATION IN UASB REACTOR

    OpenAIRE

    José Tavares de Sousa; Keliana Dantas Santos; Israel Nunes Henrique; Danielle Patrício Brasil; Eclésio Cavalcante Santos

    2008-01-01

    The environmental conditions in Brazil have been contributing to the development of anaerobic systems in the treatment of wastewaters, especially UASB - Upflow Anaerobic Sludge Blanket reactors. The classic biological process for removal of nutrients uses three reactors - Bardenpho System, therefore, this work intends an alternative system, where the anaerobic digestion and the denitrification happen in the same reactor reducing the number of reactors for two. The experimental system was con...

  11. The relationship between body composition, anaerobic performance and sprint ability of amputee soccer players.

    Science.gov (United States)

    Ozkan, Ali; Kayıhan, Gürhan; Köklü, Yusuf; Ergun, Nevin; Koz, Mitat; Ersöz, Gülfem; Dellal, Alexandre

    2012-12-01

    The purpose of the present study was to investigate the relationship between body composition, anaerobic performance and sprint performance of amputee soccer players. Fifteen amputee soccer players participated in this study voluntarily. Subjects' height, body weight, body mass index, body fat percentage (Jackson and Pollock formula) and somatotype characteristics (Heath-Carter system) were determined. The sprint performance at 10m, 20m and 30m was evaluated, whereas the counter movement jump (CMJ), relative CMJ (RCMJ), squat jump (SJ) and relative SJ (RSJ) tests were used for the determination of anaerobic performance. The results of the Pearson Product Moment correlation analysis indicated that body composition was significantly correlated with CMJ and SJ (p 0.05). A significant correlation was found between CMJ, RCMJ, SJ, 10 m, 20 m and 30 m sprint performance (p sprint performance (p > 0.05). In conclusion, the findings of the present study indicated that sprint performance was described as an essential factor in anaerobic performance whereas body composition and somatotype play a determinant role in anaerobic and sprint performance in amputee soccer players.

  12. Cold tolerance is unaffected by oxygen availability despite changes in anaerobic metabolism

    Science.gov (United States)

    Boardman, Leigh; Sørensen, Jesper G.; Koštál, Vladimír; Šimek, Petr; Terblanche, John S.

    2016-09-01

    Insect cold tolerance depends on their ability to withstand or repair perturbations in cellular homeostasis caused by low temperature stress. Decreased oxygen availability (hypoxia) can interact with low temperature tolerance, often improving insect survival. One mechanism proposed for such responses is that whole-animal cold tolerance is set by a transition to anaerobic metabolism. Here, we provide a test of this hypothesis in an insect model system (Thaumatotibia leucotreta) by experimental manipulation of oxygen availability while measuring metabolic rate, critical thermal minimum (CTmin), supercooling point and changes in 43 metabolites in moth larvae at three key timepoints (before, during and after chill coma). Furthermore, we determined the critical oxygen partial pressure below which metabolic rate was suppressed (c. 4.5 kPa). Results showed that altering oxygen availability did not affect (non-lethal) CTmin nor (lethal) supercooling point. Metabolomic profiling revealed the upregulation of anaerobic metabolites and alterations in concentrations of citric acid cycle intermediates during and after chill coma exposure. Hypoxia exacerbated the anaerobic metabolite responses induced by low temperatures. These results suggest that cold tolerance of T. leucotreta larvae is not set by oxygen limitation, and that anaerobic metabolism in these larvae may contribute to their ability to survive in necrotic fruit.

  13. Application of Hydrothermal Treatment to High Concentrated Sewage Sludge for Anaerobic Digestion Process

    Directory of Open Access Journals (Sweden)

    M. Orikawa

    2013-10-01

    Full Text Available Tomato and seaweed were produced by utilizing CO2 and heat discharged from power generation using biogas in Toyogawa biomass park, Japan. The biogas was obtained by anaerobic digestion with hydrothermal treatment. The hydrothermal treatment was applied to the high concentrated sewage sludge (22 % total solids (TS dewatered sludge. The purpose of this study is to clarify the effect of hydrothermal treatment on the qualities of high concentrated sewage sludge, by analyzing particulate organic carbon (POC and dissolved organic carbon (DOC. The hydrothermal treatment was investigated under 10-60 min of treatment time, 180-200 °C of temperature, 10-22 %-TS of sewage sludge concentration. The results showed that the DOC in each conditions increased through hydrothermal treatment. The highest DOC obtained was 67 % of total carbon concentration, when the temperature was 180 °C, treatment time was 60 min and sewage sludge concentration was 10 %-TS. Furthermore, the viscosity of treated sewage sludge was decreased by hydrothermal treatment. In batch anaerobic digestion test, methane gas production was confirmed. In addition, this study evaluated the energy balance of this system. Thus, the results of this study indicated that the possibility of application of hydrothermal treatment to high concentrated sewage sludge for anaerobic digestion process. Keywords: anaerobic reaction, hydrothermal treatment, sewage sludge, solubilization

  14. Biosorption of Cu(II) by powdered anaerobic granular sludge from aqueous medium.

    Science.gov (United States)

    Zhou, Xu; Chen, Chuan; Wang, Aijie; Jiang, Guangming; Liu, Lihong; Xu, Xijun; Yuan, Ye; Lee, Duu-Jung; Ren, Nanqi

    2013-01-01

    Copper(II) biosorption processes by two pre-treated powdered anaerobic granular sludges (PAGS) (original sludges were methanogenic anaerobic granules and denitrifying sulfide removal (DSR) anaerobic granules) were investigated through batch tests. Factors affecting the biosorption process, such as pH, temperature and initial copper concentrations, were examined. Also, the physico-chemical characteristics of the anaerobic sludge were analyzed by Fourier transform infrared spectroscopy, scanning electron microscopy image, surface area and elemental analysis. A second-order kinetic model was applied to describe the biosorption process, and the model could fit the biosorption process. The Freundlich model was used for describing the adsorption equilibrium data and could fit the equilibrium data well. It was found that the methanogenic PAGS was more effective in Copper(II) biosorption process than the DSR PAGS, whose maximum biosorption capacity was 39.6% lower. The mechanisms of the biosorption capacities for different PAGS were discussed, and the conclusion suggested that the environment and biochemical reactions during the growth of biomass may have affected the structure of the PAGS. The methanogenic PAGS had larger specific surface area and more biosorption capacity than the DSR PAGS.

  15. The Relationship Between Body Composition, Anaerobic Performance and Sprint Ability of Amputee Soccer Players

    Science.gov (United States)

    Özkan, Ali; Kayıhan, Gürhan; Köklü, Yusuf; Ergun, Nevin; Koz, Mitat; Ersöz, Gülfem; Dellal, Alexandre

    2012-01-01

    The purpose of the present study was to investigate the relationship between body composition, anaerobic performance and sprint performance of amputee soccer players. Fifteen amputee soccer players participated in this study voluntarily. Subjects’ height, body weight, body mass index, body fat percentage (Jackson and Pollock formula) and somatotype characteristics (Heath-Carter system) were determined. The sprint performance at 10m, 20m and 30m was evaluated, whereas the counter movement jump (CMJ), relative CMJ (RCMJ), squat jump (SJ) and relative SJ (RSJ) tests were used for the determination of anaerobic performance. The results of the Pearson Product Moment correlation analysis indicated that body composition was significantly correlated with CMJ and SJ (p 0.05). A significant correlation was found between CMJ, RCMJ, SJ, 10 m, 20 m and 30 m sprint performance (p 0.05). In conclusion, the findings of the present study indicated that sprint performance was described as an essential factor in anaerobic performance whereas body composition and somatotype play a determinant role in anaerobic and sprint performance in amputee soccer players. PMID:23486067

  16. Anaerobic threshold employed on exercise training prescription and performance assessment for laboratory rodents: A short review.

    Science.gov (United States)

    Abreu, Phablo; Mendes, Sávio Victor Diogenes; Leal-Cardoso, José Henrique; Ceccatto, Vânia Marilande

    2016-04-15

    Several studies have generated numerous terms in the field of exercise training prescription and performance assessment that often do not match the information previously demonstrated by many other works, generating much debate and resulting in an immense pool of scientific results. Several protocols in exercise training prescription and performance assessment have been proposed for these purposes by many reasons. In the field of exercise science, the protocol must be thoroughly investigated and provide real tools to be reproducible. Many laboratories have been adapting and developing evaluation protocols and testing on physical training of rodents in different experimental conditions. In this context, mice, rats and rabbits are preferentially chosen due to easy manipulation and good response to exercise, and comparable at results obtained with humans in compatible effort intensities. But, the exercise training programs and aerobic-anaerobic transition assessment proposed for animal models vary extensively, depending on the species, gender, age, type of stimulus, type of exercise, type of method and also on the specific objectives of the program. This short review demonstrates the need in offering tools performed by invasive measurement to assess the anaerobic threshold by blood lactate employed on evolution of aerobic-anaerobic parameters of rodents. The objective of this short review was to present and to discuss physical evaluation protocols applications to rodents. The table submitted may give a basis for anaerobic threshold employed on exercise training prescription and performance assessment for laboratory rodents in future research. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Bacteremia due to anaerobic bacteria: epidemiology in a northern Bari Hospital, Italy

    Directory of Open Access Journals (Sweden)

    Maria Antonietta Distasi

    2015-06-01

    Full Text Available Background. Anaerobic bacteria are part of the commensal bacterial flora of skin and mucosae. Iatrogenic and pathological conditions altering this commensal relationship cause life-threatening diseases. Materials and Methods. We analysed the blood cultures sent to the microbiology of our hospital between 2008 and the first quarter of 2013 to measure the frequency of bacteraemia caused by anaerobia. We examined 3138 vials of blood cultures for anaerobia, inoculated following in-house standard procedures. The colonies grown in absence of air were subjected to biochemical analysis. The MICs of metronidazole for 23 of the 26 organisms was tested. Results. Twelve bacteria of the Bacteroides genus were identified, 9 Propionibacterium acnes, 1 Peptosctreptococcus micros, 1 Lactobacillus acidophilus, 1 Clostridium perfringens, 1 Prevotella oralis, 1 Eubacterium lentum. Conclusions. The analysis of the results suggests that the incidence of cultures positive to anaerobia was constant across the years. We note that advanced age, altered mucocutaneous tropism, alterations to the oral and intestinal bacterial flora intensify the risk of anaerobial pathogenicity. The analysis of the metronidazole-determined MIC suggests that the intestinal anaerobic flora responds well to therapy and prophylaxis with Metronidazole, while the anaerobic bacteria residing on skin and other mucosae are resistant. It is however hard to determine the clinical impact of anaerobic bacteremiae and their effect on the outcome of the patient, due to the scarcity of available clinical data.

  18. Anaerobic digestion of wastewater screenings for resource recovery and waste reduction

    Science.gov (United States)

    Wid, N.; Horan, N. J.

    2016-06-01

    Wastewater screenings are produced during the first stage of the wastewater treatment process and at present are disposed of to landfill. This material may not only cause operational failure to the treatment system, but also lead to environmental problems. In view of the high organic content of screenings, anaerobic digestion method may not only offer the potential for energy recovery, but also nutrient. In this study the, anaerobic batch digestion was performed at different dry solids concentrations of screenings to study the potential of biogas and phosphorus recovery. The tests demonstrated wastewater screenings were amenable to anaerobic digestion with methane yield was 355 m3/kg VS, which are comparable to the previous results. The digestate was high in P content and can be recovered up to 41%. This study also shows that anaerobic digestion was not only to turn this waste into useful resources, but also has a potential in reducing the organic content up to 31% for safe disposal. In this way the amount of wastewater screenings going to landfill is not only can be reduced, but also valuable products such as methane and phosphorus can also be recovered.

  19. Integrated biogas upgrading and hydrogen utilization in an anaerobic reactor containing enriched hydrogenotrophic methanogenic culture

    DEFF Research Database (Denmark)

    Luo, Gang; Angelidaki, Irini

    2012-01-01

    Biogas produced by anaerobic digestion, is mainly used in a gas motor for heat and electricity production. However, after removal of CO2, biogas can be upgraded to natural gas quality, giving more utilization possibilities, such as utilization as autogas, or distant utilization by using the exist......Biogas produced by anaerobic digestion, is mainly used in a gas motor for heat and electricity production. However, after removal of CO2, biogas can be upgraded to natural gas quality, giving more utilization possibilities, such as utilization as autogas, or distant utilization by using...... the existing natural gas grid. The current study presents a new biological method for biogas upgrading in a separate biogas reactor, containing enriched hydrogenotrophic methanogens and fed with biogas and hydrogen. Both mesophilic- and thermophilic anaerobic cultures were enriched to convert CO2 to CH4...... by PCR–DGGE. Nonetheless, they all belonged to the order Methanobacteriales, which can mediate hydrogenotrophic methanogenesis. Biogas upgrading was then tested in a thermophilic anaerobic reactor under various operation conditions. By continuous addition of hydrogen in the biogas reactor, high degree...

  20. Treatment of winery wastewater with an anaerobic rotating biological contactor.

    Science.gov (United States)

    Arnaud, Th

    2009-01-01

    Performances of an anaerobic rotating biological contactor (AnRBC) have been tested with winery wastewater. A 50 litres pilot has been used during a 4 month period. It was observed that the start-up took place in one month until the biofilm stabilized. Optimal performances were obtained with a COD removal close to 80%, with the following conditions: temperature of wastewater at 20 degrees C, volume load of 2 kg COD m(-3) d(-1), mass load of 0.3 kg COD kg MVS(-1) d(-1), surface load of 0.11 kg COD m(-2) d(-1). However, it is possible to enhance some experimental conditions to obtain better results, especially in increasing the total surface of the biodisk and in controlling temperature to the mesophilic optimal value (37 degrees C). In such conditions it is estimated that for 80% COD removal, volume load could approach 20 to 25 kg COD m(-3) d(-1).

  1. Innovative microbial fuel cell for electricity production from anaerobic reactors

    DEFF Research Database (Denmark)

    Min, Booki; Angelidaki, Irini

    2008-01-01

    A submersible microbial fuel cell (SMFC) was developed by immersing an anode electrode and a cathode chamber in an anaerobic reactor. Domestic wastewater was used as the medium and the inoculum in the experiments. The SMFC could successfully generate a stable voltage of 0.428 ± 0.003 V with a fixed...... 470 Ω resistor from acetate. From the polarization test, the maximum power density of 204 mW m−2 was obtained at current density of 595 mA m−2 (external resistance = 180 Ω). The power generation showed a saturation-type relationship as a function of wastewater strength, with a maximum power density...... (Pmax) of 218 mW m−2 and a saturation constant (Ks) of 244 mg L−1. The main limitations for achieving higher electricity production in the SMFC were identified as the high internal resistance at the electrolyte and the inefficient electron transfer at the cathode electrode. As the current increased...

  2. Recovery of gastrointestinal swine parasites in anaerobic biodigester systems.

    Science.gov (United States)

    Cañon-Franco, William Alberto; Henao-Agudelo, Ricardo Andrés; Pérez-Bedoya, José Leandro

    2012-01-01

    Solid and liquid wastes from livestock operations represent important challenges for animal production regarding their impact in the environment and public health. Parasitological tests performed on 80 samples of affluent and effluent waters from three anaerobic biodigestors with flexible structure from swine farms of Caldas - Colombia, showed the presence of Isospora suis (45%), Eimeria suis (42.5%), E. espinosa (35%), Strongyloides ransomi (28.8%), E. perminuta (12.5%), E. cerdonis (3.8%), and E. porci (2.5%). The additional finding of eggs of Taenia spp. in 10% of the samples was probably caused by a connection between the human sewage system and the biodigester. Although we observed a mean decrease of 65.6% of parasites, these levels were insufficient to meet the minimum requirement set by Engelberg's guidelines regarding water quality. This study demonstrates the serious environmental impact that an inadequately treated animal wastewater represents, and has important implications for water resources and human health.

  3. Anaerobic sludge digestion with a biocatalytic additive. [Lactobacillus acidophilus

    Energy Technology Data Exchange (ETDEWEB)

    Ghosh, S.; Henry, M.P.; Fedde, P.A.

    1982-01-01

    Aimed at improving the process operating characteristics of anaerobic digestion for sludge stabilization and SNG production, this study evaluates the effects of a lactobacillus additive under normal, variable, and overload conditions. This whey fermentation product of an acid-tolerant strain of L. acidophilus fortified with CoCO/sub 3/, (NH/sub 4/)/sub 2/HPO/sub 4/, ferrous lactate, and lactic acid provides growth factors, metabolic intermediates, and enzymes needed for substrate degradation and cellular synthesis. Data indicate that the biochemical additive increases methane yield, gas production rate, and volatile solids reduction; decreases volatile acids accumulation; enhances the digester buffer capacity; and improves the fertilizer value and dewatering characteristics of the digested residue. Digester capacities could be potentially doubled when the feed is so treated. Results of field tests with six full-scale digesters confirm observations made with bench-scale digesters.

  4. The effect of radiation on the anaerobic corrosion of steel

    Science.gov (United States)

    Smart, N. R.; Rance, A. P.; Werme, L. O.

    2008-09-01

    To ensure the safe encapsulation of spent nuclear fuel elements for geological disposal, SKB of Sweden are considering using a canister, which consists of an outer copper canister and a cast iron insert. Previous work has investigated the rate of gas generation due to the anaerobic corrosion of ferrous materials over a range of conditions. This paper examines the effect of radiation on the corrosion of steel in repository environments. Tests were carried out at two temperatures (30 °C and 50 °C), two dose rates (11 Gray h -1 and 300 Gray h -1) and in two different artificial groundwaters, for exposure periods of several months. Radiation was found to enhance the corrosion rate at both dose rates but the greatest enhancement occurred at the higher dose rate. The corrosion products were predominantly magnetite, with some indications of unidentified higher oxidation state corrosion products being formed at the higher dose rates.

  5. Analysis of physical fitness and technical skills of youth soccer players according to playing position

    OpenAIRE

    Joo, Chang Hwa; Seo, Dong-il

    2016-01-01

    The purpose of this study was to compare performance factors of youth soccer players according to position. A total of 101 high school soccer players were selected and were classified into goalkeeper (n=7), defense (n=37), midfield (n=39), and forward (n=18) positions. All subjects were subjected to the Wingate test for anaerobic capacity, shuttle run test for aerobic capacity, and pass, kick, dribble, and shooting tests for soccer skills. There was no significant difference in aerobic capaci...

  6. Evaluation of anaerobic threshold in non-pregnant and pregnant rats

    Directory of Open Access Journals (Sweden)

    ALINE OLIVEIRA NETTO

    2017-12-01

    Full Text Available ABSTRACT Several studies present different methodologies and results about intensity exercise, and many of them are performed in male rats. However, the impact of different type, intensity, frequency and duration of exercise on female rats needs more investigation. From the analysis of blood lactate concentration during lactate minimum test (LacMin in the swimming exercise, the anaerobic threshold (AT was identified, which parameter is defined as the transition point between aerobic and anaerobic metabolism. LacMin test is considered a good indicator of aerobic conditioning and has been used in prescription of training in different exercise modalities. However, there is no evidence of LacMin test in female rats. The objective was to determine AT in non-pregnant and pregnant Wistar rats. The LacMin test was performed and AT defined for mild exercise intensity was from a load equivalent to 1% of body weight (bw, moderate exercise as carrying 4% bw and severe intensity as carrying 7% bw. In pregnant rats, the AT was reached at a lower loading from 5.0% to 5.5% bw, while in non-pregnant the load was from 5.5% to 6.0% bw. Thus, this study was effective to identify exercise intensities in pregnant and non-pregnant rats using anaerobic threshold by LacMin test.

  7. Microbial kinetic for In-Storage-Psychrophilic Anaerobic Digestion (ISPAD).

    Science.gov (United States)

    Madani-Hosseini, Mahsa; Mulligan, Catherine N; Barrington, Suzelle

    2014-12-15

    In-Storage-Psychrophilic-Anaerobic-Digestion (ISPAD) is a wastewater storage tank converted into an anaerobic digestion (AD) system by means of an airtight floating geo-membrane. For process optimization, ISPAD requires modelling with well-established microbial kinetics coefficients. The present objectives were to: obtain kinetics coefficients for the modelling of ISPAD; compare the prediction of the conventional and decomposition fitting approach, an innovative fitting technique used in other fields of science, and; obtain equations to predict the maximum growth rate (μmax) of microbial communities as a function of temperature. The method consisted in conducting specific Substrate Activity Tests (SAT) using ISPAD inoculum to monitor the rate of degradation of specific substrates at 8, 18 and 35 °C. Microbial kinetics coefficients were obtained by fitting the Monod equations to SAT. The statistical procedure of Least Square Error analysis was used to minimize the Sum of Squared Errors (SSE) between the measured ISPAD experimental data and the Monod equation values. Comparing both fitting methods, the decomposition approach gave higher correlation coefficient (R) for most kinetics values, as compared to the conventional approach. Tested to predict μmax with temperature, the Square Root equation better predicted temperature dependency of both acidogens and propionate degrading acetogens, while the Arrhenius equation better predicted that of methanogens and butyrate degrading acetogens. Increasing temperature from 18 to 35 °C did not affect butyrate degrading acetogens, likely because of their dominance, as demonstrated by microbial population estimation. The estimated ISPAD kinetics coefficients suggest a robust psychrophilic and mesophilic coexisting microbial community demonstrating acclimation to ambient temperature. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Reductive Anaerobic Biological In Situ Treatment Technology Treatability Testing

    National Research Council Canada - National Science Library

    Alleman, Bruce

    2002-01-01

    Enhanced biological reductive dechlorination (EBRD) shows a great deal of promise for efficiently treating groundwater contaminated with chlorinated solvents, but demonstration sites around the country were reporting mixed results...

  9. Effect of increasing nitrobenzene loading rates on the performance of anaerobic migrating blanket reactor and sequential anaerobic migrating blanket reactor/completely stirred tank reactor system

    Energy Technology Data Exchange (ETDEWEB)

    Kuscu, Ozlem Selcuk [Department of Environmental Engineering, Faculty of Engineering and Architecture, Sueleyman Demirel University, 32360, Isparta (Turkey); Sponza, Delia Teresa, E-mail: delya.sponza@deu.edu.tr [Department of Environmental Engineering, Faculty of Engineering, Dokuz Eyluel University, Buca Kaynaklar Campus, 35160, Izmir (Turkey)

    2009-08-30

    A laboratory scale anaerobic migrating blanket reactor (AMBR) reactor was operated at nitrobenzene (NB) loading rates increasing from 3.33 to 66.67 g NB/m{sup 3} day and at a constant hydraulic retention time (HRT) of 6 days to observe the effects of increasing NB concentrations on chemical oxygen demand (COD), NB removal efficiencies, bicarbonate alkalinity, volatile fatty acid (VFA) accumulation and methane gas percentage. Moreover, the effect of an aerobic completely stirred tank reactor (CSTR) reactor, following the anaerobic reactor, on treatment efficiencies was also investigated. Approximately 91-94% COD removal efficiencies were observed up to a NB loading rate of 30.00 g/m{sup 3} day in the AMBR reactor. The COD removal efficiencies decreased from 91% to 85% at a NB loading rate of 66.67 g/m{sup 3} day. NB removal efficiencies were approximately 100% at all NB loading rates. The maximum total gas, methane gas productions and methane percentage were found to be 4.1, 2.6 l/day and 59%, respectively, at a NB loading rate of 30.00 g/m{sup 3} day. The optimum pH values were found to be between 7.2 and 8.4 for maximum methanogenesis. The total volatile fatty acid (TVFA) concentrations in the effluent were 110 and 70 mg/l in the first and second compartments at NB loading rates as high as 66.67 and 6.67 g/m{sup 3} day, respectively, while they were measured as zero in the effluent of the AMBR reactor. In this study, from 180 mg/l NB 66 mg/l aniline was produced in the anaerobic reactor while aniline was completely removed and transformed to 2 mg/l of cathechol in the aerobic CSTR reactor. Overall COD removal efficiencies were found to be 95% and 99% for NB loading rates of 3.33 and 66.67 g/m{sup 3} day in the sequential anaerobic AMBR/aerobic CSTR reactor system, respectively. The toxicity tests performed with Photobacterium phosphoreum (LCK 480, LUMIStox) and Daphnia magna showed that the toxicity decreased with anaerobic/aerobic sequential reactor system from

  10. A multi-criteria ranking of different technologies for the anaerobic digestion for energy recovery of the organic fraction of municipal solid wastes.

    Science.gov (United States)

    Karagiannidis, A; Perkoulidis, G

    2009-04-01

    This paper describes a conceptual framework and methodological tool developed for the evaluation of different anaerobic digestion technologies suitable for treating the organic fraction of municipal solid waste, by introducing the multi-criteria decision support method Electre III and demonstrating its related applicability via a test application. Several anaerobic digestion technologies have been proposed over the last years; when compared to biogas recovery from landfills, their advantage is the stability in biogas production and the stabilization of waste prior to final disposal. Anaerobic digestion technologies also show great adaptability to a broad spectrum of different input material beside the organic fraction of municipal solid waste (e.g. agricultural and animal wastes, sewage sludge) and can also be used in remote and isolated communities, either stand-alone or in conjunction to other renewable energy sources. Main driver for this work was the preliminary screening of such methods for potential application in Hellenic islands in the municipal solid waste management sector. Anaerobic digestion technologies follow different approaches to the anaerobic digestion process and also can include production of compost. In the presented multi-criteria analysis exercise, Electre III is implemented for comparing and ranking 5 selected alternative anaerobic digestion technologies. The results of a performed sensitivity analysis are then discussed. In conclusion, the performed multi-criteria approach was found to be a practical and feasible method for the integrated assessment and ranking of anaerobic digestion technologies by also considering different viewpoints and other uncertainties of the decision-making process.

  11. Effects of High-Intensity Training on Anaerobic and Aerobic Contributions to Total Energy Release During Repeated Supramaximal Exercise in Obese Adults.

    Science.gov (United States)

    Jabbour, Georges; Iancu, Horia-Daniel; Paulin, Anne

    Studying relative anaerobic and aerobic metabolism contributions to total energy release during exercise may be valuable in understanding exercise energetic demands and the energetic adaptations that occur in response to acute or chronic exercise in obese adults. The aim of the present study is to evaluate the effects of 6 weeks of high-intensity training (HIT) on relative anaerobic and aerobic contributions to total energy release and on peak power output during repeated supramaximal cycling exercises (SCE) in obese adults. Twenty-four obese adults (body mass index = ± 33 kg.m(-2)) were randomized into a control group (n = 12) and an HIT group (n = 12). Accumulated oxygen deficits (ml.min(-1)) and anaerobic and aerobic contributions (%) were measured in all groups before and after training via repeated SCE. In addition, the peak power output performed during SCE was determined using the force-velocity test. Before HIT, anaerobic contributions to repeated SCE did not differ between the groups and decreased significantly during the third and fourth repetitions. After HIT, anaerobic contributions increased significantly in the HIT group (+11 %, p anaerobic contributions (r = 0.9, p anaerobic contributions to energy release which were associated with peak power enhancement in response to repeated SCE. Consequently, HIT may be an appropriate approach for improving energy contributions and muscle power among obese adults.

  12. [Distribution and removal of anaerobic antibiotic resistant bacteria during mesophilic anaerobic digestion of sewage sludge].

    Science.gov (United States)

    Tong, Juan; Wang, Yuan-Yue; Wei Yuan, Song

    2014-10-01

    Sewage sludge is one of the major sources that releasing antibiotic resistant bacteria (ARB) and antibiotic resistant genes (ARG) into the environment since it contains large amount of ARB, but there is little information about the fate of the anaerobic ARB in the anaerobic digestion of sewage sludge. Therefore, the distribution, removal and seasonal changes of tetracycline and β-lactam antibiotics resistant bacteria in the mesophilic egg-shaped digesters of a municipal wastewater treatment plant were investigated for one year in this study. Results showed that there were higher amounts of ARB and higher resistance rate of β-lactam antibiotics than that of tetracycline antibiotics in the sewage sludge. All ARB could be significantly reduced during the mesophilic anaerobic digestion process by 1.48-1.64 log unit (P resistance rates were significantly increased after anaerobic digestion by 12.0% and 14.3%, respectively (P sludge had seasonal change characteristics. Except for chlorotetracycline resistant bacteria, there were more ARB in the sewage sludge in cold season than in warm season (P < 0.05).

  13. The challenges of anaerobic digestion and the role of biochar in optimizing anaerobic digestion.

    Science.gov (United States)

    Fagbohungbe, Michael O; Herbert, Ben M J; Hurst, Lois; Ibeto, Cynthia N; Li, Hong; Usmani, Shams Q; Semple, Kirk T

    2017-03-01

    Biochar, like most other adsorbents, is a carbonaceous material, which is formed from the combustion of plant materials, in low-zero oxygen conditions and results in a material, which has the capacity to sorb chemicals onto its surfaces. Currently, research is being carried out to investigate the relevance of biochar in improving the soil ecosystem, digestate quality and most recently the anaerobic digestion process. Anaerobic digestion (AD) of organic substrates provides both a sustainable source of energy and a digestate with the potential to enhance plant growth and soil health. In order to ensure that these benefits are realised, the anaerobic digestion system must be optimized for process stability and high nutrient retention capacity in the digestate produced. Substrate-induced inhibition is a major issue, which can disrupt the stable functioning of the AD system reducing microbial breakdown of the organic waste and formation of methane, which in turn reduces energy output. Likewise, the spreading of digestate on land can often result in nutrient loss, surface runoff and leaching. This review will examine substrate inhibition and their impact on anaerobic digestion, nutrient leaching and their environmental implications, the properties and functionality of biochar material in counteracting these challenges. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Growth media in anaerobic fermentative processes : The underestimated potential of thermophilic fermentation and anaerobic digestion

    NARCIS (Netherlands)

    Hendriks, A.T.W.M.; van Lier, J.B.; de Kreuk, M.K.

    2017-01-01

    Fermentation and anaerobic digestion of organic waste and wastewater is broadly studied and applied. Despite widely available results and data for these processes, comparison of the generated results in literature is difficult. Not only due to the used variety of process conditions, but also

  15. Acute Effect of Lower-Body Vibration as a Recovery Method After Fatiguing Exercise

    Directory of Open Access Journals (Sweden)

    Svetlana Nepocatych

    2015-09-01

    Full Text Available The purpose of this study was to compare three recovery methods: control (CON, lower-body vibration (LBV and LBV+ local muscle cooling (LBVC on lower-body performance, perceived recovery, and muscle soreness. Physically active male volunteers (n=8 in a repeated-measures, counterbalanced design, completed three sets of squats to fatigue, each recovery treatment, and two Wingate Anaerobic Tests. Rating of perceived exertion (RPE, and heart rate (HR were measured after fatiguing exercise, recovery treatment and Wingate Anaerobic tests. Peak and mean power, fatigue index, Delayed Onset Muscle Soreness (DOMS, and comfort levels were compared between each treatment. In Wingate 1, no significant differences (p=0.42 were found among CON, LBV, or LBVC regarding peak power (1119±239, 1097±225, and 1146±260 W, respectively, mean power (p=0.32, or fatigue index (p=0.47. In Wingate 2, no significant (p=0.17 differences were found among CON, LBV, or LBVC regarding peak power (1042±228, 1078±233, and 1110±268 W, respectively, mean power (p=0.38, or fatigue index (p=0.15. A significantly better (p=0.01 perceived recovery was observed after LBV (6±1 and LBVC (6±1 compared to CON (4±1. The study findings support psychological but not performance enhancing benefits after the use of LBV and LBVC as recovery methods.

  16. Effects of exercise continued until anaerobic threshold on balance performance in male basketball players.

    Science.gov (United States)

    Erkmen, Nurtekin; Suveren, Sibel; Göktepe, Ahmet Salim

    2012-06-01

    The objective of the present study was to determine the effects of exercise continued until the anaerobic threshold on balance performance in basketball players. Twelve male basketball players (age = 20.92 ± 2.81 years, body height = 192.72 ± 7.61 cm, body mass = 88.09 ± 8.41 kg, training experience = 7.17 ± 3.10 years) volunteered to participate in this study. A Kinesthetic Ability Trainer (KAT 2000 stabilometer) was used to measure the balance performance. Balance tests consisted of static tests on dominant, nondominant and double leg stance. The Bruce Protocol was performed by means of a treadmill. The exercise protocol was terminated when the subject passed the anaerobic threshold. After the exercise protocol, balance measurements were immediately repeated. Statistical differences between pre and post-exercise for dominant, nondominant and double leg stance were determined by the paired samples t-test according to the results of the test of normality. The post-exercise balance score on the dominant leg was significantly higher than pre-exercise (t = -2.758, p exercise in the balance scores of the nondominant leg after the exercise protocol (t = 0.428, p > 0.05). A significant difference was found between pre and post-exercise balance scores in the double leg stance (t = -2.354, p exercise continued until the anaerobic threshold decreased balance performance on the dominant leg in basketball players, but did not alter it in the nondominant leg.

  17. Influence of operational conditions on biofilm specific activity of an anaerobic fluidized bed reactor.

    Science.gov (United States)

    García-Morales, J L; Romero, L I; Sales, D

    2003-01-01

    A key parameter in water and wastewater treatment technology is the biomass activity in terms of substrate removal ability. The effects of organic load rate and percentage of bed expansion on biofilm specific methanogenic activity were determined in an anaerobic fluidized bed reactor treating wine-distillery wastes in the thermophilic range (55 degrees C). The proposed activity tests are highly reproducible: an experiment with three identical tests has shown that the standard deviation with respect to the mean values is less than 3%. Specific tests are applied to measure the maximum methanogenic activities of the biomass carrier in lab-scale anaerobic biofilm reactors. These tests have been successfully applied for monitoring the support colonization process and the evolution of biofilm activity in reactors, anaerobic filter and fluidized bed, with different operating conditions. The results show a dependence between the percentage of bed expansion and the specific activity of methanogenic microbiote on biofilm. There is a relationship between the percentage of bed expansion, the sheer stress on the biofilm and the hydrodynamic conditions in the system. Initial biofilm detachment can be compensated with the increase of biomass and of its activity due to the reduction of the substrate diffusional limitations to the microorganism growth inside the support pores.

  18. Anaerobic wastewater treatment of concentrated sewage using a two-stage upflow anaerobic sludge blanket- anaerobic filter system.

    Science.gov (United States)

    Halalsheh, Maha M; Abu Rumman, Zainab M; Field, Jim A

    2010-01-01

    A two-stage pilot-scale upflow anaerobic sludge blanket - anaerobic filter (UASB-AF) reactors system treating concentrated domestic sewage was operated at 23 degrees C and at hydraulic retention times (HRT) of 15 and 4 h, respectively. Excess sludge from the downstream AF stage was returned to the upstream UASB reactor. The aim was to obtain higher sludge retention time (SRT) in the UASB reactor for better methanization of suspended COD. The UASB-AF system removed 55% and 65% of the total COD (COD(tot)) and suspended COD (COD(ss)), respectively. The calculated SRT in the UASB reactor ranged from 20-35 days. The AF reactor removed the washed out sludge from the first stage reactor with average COD(ss) removal efficiency of 55%. The volatile fatty acids concentration in the effluent of the AF was 39 mg COD/L compared with 78 mg COD/L measured for the influent. The slightly higher COD(tot) removal efficiency obtained in this study compared with a single stage UASB reactor was achieved at 17% reduction in the total volume.

  19. Applications of the anaerobic digestion process

    DEFF Research Database (Denmark)

    Angelidaki, Irini; Ellegaard, L.; Ahring, Birgitte Kiær

    2003-01-01

    and resource/energy recovery have been developed. Treatment of biowastes by anaerobic digestion processes is in many cases the optimal way to convert organic waste into useful products such as energy (in the form of biogas) and a fertilizer product. Other waste management options, such as land filling...... and incineration of organic waste has become less desirable, and legislation, both in Europe and elsewhere, tends to favor biological treatment as a way of recycling minerals and nutrients of organic wastes from society back to the food production and supply chain. Removing the relatively wet organic waste from...

  20. Improvement of anaerobic digestion of sludge

    Energy Technology Data Exchange (ETDEWEB)

    Dohanyos, Michael; Zabranska, Jana; Kutil, Josef; Jenicek, Pavel

    2003-07-01

    Anaerobic digestion improvement can be accomplished by different methods. Besides optimization of process conditions is frequently used pretreatment of input sludge and increase of process temperature. Thermophilic process brings a higher solids reduction and biogas production, the high resistance to foaming, no problems with odour, the higher effect of destroying pathogens and the improvement of the energy balance of the whole treatment plant. Disintegration of excess activated sludge in lysate centrifuge was proved in full-scale conditions causing increase of biogas production. The rapid thermal conditioning of digested sludge is acceptable method of particulate matter disintegration and solubilization. (author)

  1. [Anaerobic cervical cellulitis: a therapeutic approach].

    Science.gov (United States)

    Mevio, E

    1993-01-01

    The possibility of life-threatening complications arising from cervico-facial infections is well known. Deep cervical infections, however, rarely spread to the mediastinus. Organisms responsible for these infections usually include either aerobic or anaerobic microorganisms, whose synergistic activity provokes virulence and contributes to the violent nature of infection. Prompt recognition is vital if appropriate treatment is to be given. Initial management of deep-neck infections consists in intensive parenteral antibiotic therapy. Nevertheless, in spite of antibiotic therapy, mortality due to suppurative mediastinitis remains high. The Author emphasizes the importance and gives priority to surgical drainage and debridement, another fundamental part of treatment.

  2. Psychrophilic anaerobic digestion of human waste

    Energy Technology Data Exchange (ETDEWEB)

    Meher, K.K.; Gollakota, K.G. [Tata Research Development and Design Center, Pune (India); Murthy, M.V.S. [Research and Development Engineers, Dighi, Pune (India)

    1994-12-31

    Human waste was degraded into biogas at a psychrophilic temperature of 15 {+-} 1{sup o}C. Below 20{sup o}C methane production was observed only with the addition of temperature-adapted seed culture. Biogas produced was 0.148 m{sup 3} per kg total solids degraded/per day, at 30 day retention time, and methane content was 57%. Pathogenic bacterial content per 100 ml in the human waste was reduced from an initial 10{sup 24} to 10{sup 3} after the anaerobic and chemical treatments. COD and BOD were reduced by up to 97 and 40% respectively. Total solids reduction was 77%. (author)

  3. Hybrid modelling of anaerobic wastewater treatment processes.

    Science.gov (United States)

    Karama, A; Bernard, O; Genovesi, A; Dochain, D; Benhammou, A; Steyer, J P

    2001-01-01

    This paper presents a hybrid approach for the modelling of an anaerobic digestion process. The hybrid model combines a feed-forward network, describing the bacterial kinetics, and the a priori knowledge based on the mass balances of the process components. We have considered an architecture which incorporates the neural network as a static model of unmeasured process parameters (kinetic growth rate) and an integrator for the dynamic representation of the process using a set of dynamic differential equations. The paper contains a description of the neural network component training procedure. The performance of this approach is illustrated with experimental data.

  4. Anaerobic xylose fermentation by Spathaspora passalidarum

    DEFF Research Database (Denmark)

    Hou, Xiaoru

    2012-01-01

    A cost-effective conversion of lignocellulosic biomass into bioethanol requires that the xylose released from the hemicellulose fraction (20–40% of biomass) can be fermented. Baker’s yeast, Saccharomyces cerevisiae, efficiently ferments glucose but it lacks the ability to ferment xylose. Xylose-fermenting...... yeast such as Pichia stipitis requires accurately controlled microaerophilic conditions during the xylose fermentation, rendering the process technically difficult and expensive. In this study, it is demonstrated that under anaerobic conditions Spathaspora passalidarum showed high ethanol production...

  5. Comparison of a new test for agility and skill in soccer with other agility tests.

    Science.gov (United States)

    Kutlu, Mehmet; Yapıcı, Hakan; Yoncalık, Oğuzhan; Celik, Serkan

    2012-06-01

    The purpose of this study was both to develop a novel test to measure run, shuttle run and directional change agility, and soccer shots on goal with decision making and to compare it with other agility tests. Multiple comparisons and assessments were conducted, including test-retest, Illinois, Zig-Zag, 30 m, Bosco, T-drill agility, and Wingate peak power tests. A total of 113 Turkish amateur and professional soccer players and tertiary-level students participated in the study. Test-retest and inter-tester reliability testing measures were conducted with athletes. The correlation coefficient of the new test was .88, with no significant difference (p> 0.01> 0.01) between the test results obtained in the first and second test sessions. The results of an analysis of variance revealed a significant (p agility and power test results for soccer players. The new agility and skill test is an acceptable and reliable test when considering test-retest reliability and inter-rater reliability. The findings in this study suggest that the novel soccer-specific agility and shooting test can be utilized in the testing and identification of soccer players' talents.

  6. Transport, anoxia and energy control on anaerobic respiration and methanogenesis in anoxic peat soils

    Science.gov (United States)

    Bonaiuti, Simona; Blodau, Christian; Knorr, Klaus-Holger

    2017-04-01

    In deep and permanently water saturated peat deposits, extremely low diffusive transport and concomitant build-up of metabolic end-products, i.e of dissolved inorganic carbon (DIC) and methane (CH4), have been found to slow-down anaerobic respiration and methanogenesis. Such accumulation of DIC and CH4 lowers the Gibbs free energy yield of terminal respiration and methanogenesis, which can inhibit the course of anaerobic metabolic processes. In particular, this affects terminal steps of the breakdown of organic carbon (C), such as methanogenesis, acetogenesis and fermentation processes, which occur near thermodynamic minimum energy thresholds. This effect is thus of critical importance for the long-term C sequestration, as the slow-down of decomposition ultimately regulates the long-term fate of C in deep peat deposits. The exact controls of this observed slow-down of organic matter mineralization are not yet fully understood. Moreover, altered patterns of water or gas transport due to predicted changes in climate may affect these controls in peat soils. Therefore, the aim of this study was to investigate how burial of peat leads to an inactivation of anaerobic decomposition and to investigate the effects of advective water transport and persistently anoxic conditions on anaerobic decomposition, temporal evolution of thermodynamic energy yields to methanogenesis and methanogenic pathways. To this end, we conducted a column experiment with homogenized, ombrotrophic peat over a period of 300 days at 20˚ C. We tested i) a control treatment under diffusive transport only, ii) an advective flow treatment with a flow of 10 mm d-1, and iv) an anoxic treatment to evaluate changes in decomposition in absence of oxygen in the unsaturated zone of the cores. A slow-down of anaerobic respiration and methanogenesis generally set in at larger depths after 150 days at CH4 concentrations of 0.6-0.9 mmol L-1 and DIC concentrations of 6-12 mmol L-1. This effect occurred at higher

  7. Response of anaerobic carbon cycling to water table manipulation in an Alaskan rich fen

    Science.gov (United States)

    Kane, E.S.; Chivers, M.R.; Turetsky, M.R.; Treat, C.C.; Petersen, D.G.; Waldrop, M.; Harden, J.W.; McGuire, A.D.

    2013-01-01

    To test the effects of altered hydrology on organic soil decomposition, we investigated CO2 and CH4 production potential of rich-fen peat (mean surface pH = 6.3) collected from a field water table manipulation experiment including control, raised and lowered water table treatments. Mean anaerobic CO2 production potential at 10 cm depth (14.1 ± 0.9 μmol C g−1 d−1) was as high as aerobic CO2 production potential (10.6 ± 1.5 μmol C g−1 d−1), while CH4 production was low (mean of 7.8 ± 1.5 nmol C g−1 d−1). Denitrification enzyme activity indicated a very high denitrification potential (197 ± 23 μg N g−1 d−1), but net NO-3 reduction suggested this was a relatively minor pathway for anaerobic CO2 production. Abundances of denitrifier genes (nirK and nosZ) did not change across water table treatments. SO2-4 reduction also did not appear to be an important pathway for anaerobic CO2 production. The net accumulation of acetate and formate as decomposition end products in the raised water table treatment suggested that fermentation was a significant pathway for carbon mineralization, even in the presence of NO-3. Dissolved organic carbon (DOC) concentrations were the strongest predictors of potential anaerobic and aerobic CO2 production. Across all water table treatments, the CO2:CH4 ratio increased with initial DOC leachate concentrations. While the field water table treatment did not have a significant effect on mean CO2 or CH4 production potential, the CO2:CH4 ratio was highest in shallow peat incubations from the drained treatment. These data suggest that with continued drying or with a more variable water table, anaerobic CO2 production may be favored over CH4 production in this rich fen. Future research examining the potential for dissolved organic substances to facilitate anaerobic respiration, or alternative redox processes that limit the effectiveness of organic acids as substrates in anaerobic metabolism, would help explain additional

  8. Partition of aerobic and anaerobic swimming costs related to gait transitions in a labriform swimmer.

    Science.gov (United States)

    Svendsen, Jon C; Tudorache, Christian; Jordan, Anders D; Steffensen, John F; Aarestrup, Kim; Domenici, Paolo

    2010-07-01

    Members of the family Embiotocidae exhibit a distinct gait transition from exclusively pectoral fin oscillation to combined pectoral and caudal fin propulsion with increasing swimming speed. The pectoral-caudal gait transition occurs at a threshold speed termed U(p-c). The objective of this study was to partition aerobic and anaerobic swimming costs at speeds below and above the U(p-c) in the striped surfperch Embiotoca lateralis using swimming respirometry and video analysis to test the hypothesis that the gait transition marks the switch from aerobic to anaerobic power output. Exercise oxygen consumption rate was measured at 1.4, 1.9 and 2.3 L s(-1). The presence and magnitude of excess post-exercise oxygen consumption (EPOC) were evaluated after each swimming speed. The data demonstrated that 1.4 L s(-1) was below the U(p-c), whereas 1.9 and 2.3 L s(-1) were above the U(p-c). These last two swimming speeds included caudal fin propulsion in a mostly steady and unsteady (burst-assisted) mode, respectively. There was no evidence of EPOC after swimming at 1.4 and 1.9 L s(-1), indicating that the pectoral-caudal gait transition was not a threshold for anaerobic metabolism. At 2.3 L s(-1), E. lateralis switched to an unsteady burst and flap gait. This swimming speed resulted in EPOC, suggesting that anaerobic metabolism constituted 25% of the total costs. Burst activity correlated positively with the magnitude of the EPOC. Collectively, these data indicate that steady axial propulsion does not lead to EPOC whereas transition to burst-assisted swimming above U(p-c) is associated with anaerobic metabolism in this labriform swimmer.

  9. Understanding the impact of cationic polyacrylamide on anaerobic digestion of waste activated sludge.

    Science.gov (United States)

    Wang, Dongbo; Liu, Xuran; Zeng, Guangming; Zhao, Jianwei; Liu, Yiwen; Wang, Qilin; Chen, Fei; Li, Xiaoming; Yang, Qi

    2018-03-01

    Previous investigations showed that cationic polyacrylamide (cPAM), a flocculant widely used in wastewater pretreatment and waste activated sludge dewatering, deteriorated methane production during anaerobic digestion of sludge. However, details of how cPAM affects methane production are poorly understood, hindering deep control of sludge anaerobic digestion systems. In this study, the mechanisms of cPAM affecting sludge anaerobic digestion were investigated in batch and long-term tests using either real sludge or synthetic wastewaters as the digestion substrates. Experimental results showed that the presence of cPAM not only slowed the process of anaerobic digestion but also decreased methane yield. The maximal methane yield decreased from 139.1 to 86.7 mL/g of volatile suspended solids (i.e., 1861.5 to 1187.0 mL/L) with the cPAM level increasing from 0 to 12 g/kg of total suspended solids (i.e., 0-236.7 mg/L), whereas the corresponding digestion time increased from 22 to 26 d. Mechanism explorations revealed that the addition of cPAM significantly restrained the sludge solubilization, hydrolysis, acidogenesis, and methanogenesis processes. It was found that ∼46% of cAPM was degraded in the anaerobic digestion, and the degradation products significantly affected methane production. Although the theoretically biochemical methane potential of cPAM is higher than that of protein and carbohydrate, only 6.7% of the degraded cPAM was transformed to the final product, methane. Acrylamide, acrylic acid, and polyacrylic acid were found to be the main degradation metabolites, and their amount accounted for ∼50% of the degraded cPAM. Further investigations showed that polyacrylic acid inhibited all the solubilization, hydrolysis, acidogenesis, and methanogenesis processes while acrylamide and acrylic acid inhibited the methanogenesis significantly. Copyright © 2017 Elsevier Ltd. All rights reserved.

  10. Strategies for recovering inhibition caused by long chain fatty acids on anaerobic thermophilic biogas reactors

    DEFF Research Database (Denmark)

    Palatsi, J.; Laureni, M.; Andres, M.V.

    2009-01-01

    Long chain fatty acids (LCFA) concentrations over 1.0 g L1 were inhibiting manure thermophilic digestion, in batch and semi-continuous experiments, resulting in a temporary cease of the biogas production. The aim of the work was to test and evaluate several recovery actions, such as reactor feedi...... inhibition in manure anaerobic co-digestion. © 2009 Elsevier Ltd. All rights reserved......Long chain fatty acids (LCFA) concentrations over 1.0 g L1 were inhibiting manure thermophilic digestion, in batch and semi-continuous experiments, resulting in a temporary cease of the biogas production. The aim of the work was to test and evaluate several recovery actions, such as reactor feeding...... and reducing the bioavailable LCFA concentration, were found to be the best recovery strategies, improving the recovery time from 10 to 2 days, in semi-continuously fed systems. Moreover, acclimatization was introduced by repeated inhibition and process recovery. The subsequent exposure of the anaerobic...

  11. CHANGES IN THE ANAEROBIC THRESHOLD IN AN ANNUAL CYCLE OF SPORT TRAINING OF YOUNG SOCCER PLAYERS

    OpenAIRE

    Śliwowski, R.; Andrzejewski, M.; Wieczorek, A.; Barinow-Wojewódzki, A.; Jadczak, Ł.; Adrian, S.; Pietrzak, M.; Wieczorek, S.

    2013-01-01

    The aim of the study was to assess changes in the anaerobic threshold of young soccer players in an annual training cycle. A group of highly trained 15-18 year old players of KKS Lech Poznań were tested. The tests included an annual training macrocycle, and its individual stages resulted from the time structure of the sports training. In order to assess the level of exercise capacities of the players, a field exercise test of increasing intensity was carried out on a soccer pitch. The test ma...

  12. Modelling multiple mineral precipitation in anaerobic digester liquor.

    Science.gov (United States)

    van Rensburg, P; Musvoto, E V; Wentzel, M C; Ekama, G A

    2003-07-01

    Mineral precipitation problems have been experienced with the conveyance and treatment of anaerobically digested primary and waste activated sludge blends. This paper describes an experimental investigation into mineral precipitation in anaerobic digester liquor (ADL) from the Cape Flats (CF) Wastewater Treatment Plant (WWTP) (Cape Town, South Africa), and application of the three-phase (aqueous/solid/gas) physical and chemical processes kinetic model developed by Musvoto et al. (Water Res. 34 (2000) 1857; Water Res. 34 (2000) 1868; Water SA 26(4) (2000) 417) to the experimental data. From the experimental investigation and theoretical modelling, it is concluded inter alia that: (i) there is a close correlation between experimental measured and theoretically predicted data, (ii) the dominating mineral that precipitates is struvite, with small amounts of amorphous calcium phosphate and negligible newberyite, calcite and magnesite, (iii) the precipitation of struvite is governed by the increase in pH when CO2 is lost from the ADL, (iv) the ADL is initially undersaturated with respect to struvite, but becomes supersaturated at pH > 7.3-7.7, (v) the rate and mass of struvite precipitation are controlled by the rate of pH increase and the initial Mg concentration and (vi) the three-phase kinetic model is able to simulate accurately the time dependent precipitation data for multiple minerals competing for the same species and allows determination of specific precipitation rates for a number of minerals simultaneously in an integrated manner from a single batch test. Some operational strategies to minimise struvite precipitation are proposed.

  13. Enhancing anaerobic digestion of poultry blood using activated carbon

    Directory of Open Access Journals (Sweden)

    Maria José Cuetos

    2017-05-01

    Full Text Available The potential of using anaerobic digestion for the treatment of poultry blood has been evaluated in batch assays at the laboratory scale and in a mesophilic semi-continuous reactor. The biodegradability test performed on residual poultry blood was carried out in spite of high inhibitory levels of acid intermediaries. The use of activated carbon as a way to prevent inhibitory conditions demonstrated the feasibility of attaining anaerobic digestion under extreme ammonium and acid conditions. Batch assays with higher carbon content presented higher methane production rates, although the difference in the final cumulative biogas production was not as sharp. The digestion of residual blood was also studied under semi-continuous operation using granular and powdered activated carbon. The average specific methane production was 216 ± 12 mL CH4/g VS. This result was obtained in spite of a strong volatile fatty acid (VFA accumulation, reaching values around 6 g/L, along with high ammonium concentrations (in the range of 6–8 g/L. The use of powdered activated carbon resulted in a better assimilation of C3-C5 acid forms, indicating that an enhancement in syntrophic metabolism may have taken place. Thermal analysis and scanning electron microscopy (SEM were applied as analytical tools for measuring the presence of organic material in the final digestate and evidencing modifications on the carbon surface. The addition of activated carbon for the digestion of residual blood highly improved the digestion process. The adsorption capacity of ammonium, the protection this carrier may offer by limiting mass transfer of toxic compounds, and its capacity to act as a conductive material may explain the successful digestion of residual blood as the sole substrate.

  14. Tinidazole inhibitory and cidal activity against anaerobic periodontal pathogens.

    Science.gov (United States)

    Alou, L; Giménez, M J; Manso, F; Sevillano, D; Torrico, M; González, N; Granizo, J J; Bascones, A; Prieto, J; Maestre, J R; Aguilar, L

    2009-05-01

    The in vitro activity of tinidazole against anaerobic periodontal pathogens (25 Prevotella buccae, 18 Prevotella denticola, 10 Prevotella intermedia, 6 Prevotella melaninogenica, 5 Prevotella oralis, 10 Fusobacterium nucleatum and 8 Veillonella spp.) was determined by agar dilution. MIC(90) values (minimum inhibitory concentration for 90% of the organisms) were 8 microg/mL for Veillonella spp., 4 microg/mL for P. intermedia, 2 microg/mL for P. buccae, 1 microg/mL for Fusobacterium spp. and 0.5 microg/mL for other Prevotella spp. Cidal activity was studied by killing curves with tinidazole and amoxicillin (alone and in combination) at concentrations similar to those achieved in crevicular fluid (41.2 microg/mL tinidazole and 14.05 microg/mL amoxicillin) against an inoculum of ca. 10(7)colony-forming units/mL of four bacterial groups, each one composed of four different strains of the following periodontal isolates: Prevotella spp., Fusobacterium spp. and Veillonella spp. (anaerobes) and one amoxicillin-susceptible Streptococcus spp. (facultative) in a proportion of 1:1:1:1. When only beta-lactamase-negative Prevotella or Fusobacterium strains were tested, significantly higher reductions were found with amoxicillin (>4 log reduction at 48 h) versus controls. The presence of beta-lactamase-positive Prevotella spp. or F. nucleatum strains rendered amoxicillin inactive (no reductions at 48 h), with no differences from controls. Amoxicillin+tinidazole produced >3 log reduction at 24h and >4 log reduction at 48 h regardless of the presence or not of beta-lactamase-positive strains. The presence in crevicular fluid of beta-lactamases produced by beta-lactamase-positive periodontal pathogens may have ecological and therapeutic consequences since it may protect beta-lactamase-negative periodontal pathogens from amoxicillin treatment. In vitro, tinidazole offered high antianaerobic activity against beta-lactamase-positive and -negative periodontal pathogens, avoiding

  15. Modelling inhibitory effects of long chain fatty acids in the anaerobic digestion process

    OpenAIRE

    Flotats Ripoll, Xavier

    2013-01-01

    Mathematical modelling of anaerobic digestion process has been used to give new insights regarding dynamics of the long chain fatty acids (LCFA) inhibition. Previously published experimental data, including batch tests with clay mineral bentonite additions, were used for parameter identification. New kinetics were considered to describe the bio-physics of the inhibitory process, including: i) adsorption of LCFA over granular biomass and ii) specific LCFA substrate (saturated/unsaturated) a...

  16. Exercise may cause myocardial ischemia at the anaerobic threshold in cardiac rehabilitation programs.

    Science.gov (United States)

    Fuchs, A R C N; Meneghelo, R S; Stefanini, E; De Paola, A V; Smanio, P E P; Mastrocolla, L E; Ferraz, A S; Buglia, S; Piegas, L S; Carvalho, A A C

    2009-03-01

    Myocardial ischemia may occur during an exercise session in cardiac rehabilitation programs. However, it has not been established whether it is elicited when exercise prescription is based on heart rate corresponding to the anaerobic threshold as measured by cardiopulmonary exercise testing. Our objective was to determine the incidence of myocardial ischemia in cardiac rehabilitation programs according to myocardial perfusion SPECT in exercise programs based on the anaerobic threshold. Thirty-nine patients (35 men and 4 women) diagnosed with coronary artery disease by coronary angiography and stress technetium-99m-sestamibi gated SPECT associated with a baseline cardiopulmonary exercise test were assessed. Ages ranged from 45 to 75 years. A second cardiopulmonary exercise test determined training intensity at the anaerobic threshold. Repeat gated-SPECT was obtained after a third cardiopulmonary exercise test at the prescribed workload and heart rate. Myocardial perfusion images were analyzed using a score system of 6.4 at rest, 13.9 at peak stress, and 10.7 during the prescribed exercise (P exercise was defined as a difference > or = 2 between the summed stress score and summed rest score. Accordingly, 25 (64%) patients were classified as ischemic and 14 (36%) as nonischemic. MIBI-SPECT showed myocardial ischemia during exercise within the anaerobic threshold. The 64% prevalence of ischemia observed in the study should not be looked on as representative of the whole population of patients undergoing exercise programs. Changes in patient care and exercise programs were implemented as a result of our finding of ischemia during the prescribed exercise.

  17. Implementation of Package IBR Anaerobic Digester at the Ohio State University

    OpenAIRE

    Dustin, J. Shaun; Yu, Zhongtang; Hansen, Conly L.; Dustin, Jacob D.

    2012-01-01

    The Induced Bed Reactor (IBR) is a high rate anaerobic digester designed to treat high-solids, high strength wastes, such as those found in dairy manures and mixed solid wastes. The IBR has been successfully operated at bench, pilot and full scale. The objective of this paper is to present design and implementation of a 3,800 L pilot scale facility at The Ohio State University's OARDC facility in Wooster, OH for testing and optimization of IBR systems at small dairies.

  18. Mathematical models of anaerobic digestion for the treatment of swine effluents

    OpenAIRE

    Daisa Stéfano Fagundes; Marco Antonio Previdelli Orrico Junior; Ana Carolina Amorim Orrico; Leonardo de Oliveira Seno

    2015-01-01

    ABSTRACT Pig breeding results in the production of large amounts of waste, which can cause serious environmental problems, when handled incorrectly. This study aimed at testing mathematical models to estimate the parameters of anaerobic biodigestion in biodigesters as a function of the composition of swine effluents with and without separation of the solid fraction and hydraulic retention times (HRT). Semi-continuous biodigesters fed with swine effluents with and without separation of the sol...

  19. The activity of microorganisms as control parameters of anaerobic reactors; La actividad de los microorganismos como parametro de control de reactores anaerobios

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Morales, J.L.; Romero Garcia, L.I.; Sales Marquez, D.

    1998-04-01

    Anaerobic digestion is a well established technology for treatment of sludge and several industrial wastewater. Also, thermophilic anaerobic digestion is of interest for the treatment of wastes and, indeed, thermophilic processes have been found to be higher than mesophilic processes in terms of removal rate of organic matter. A number of authors has attempted to characterize anaerobic reactor biomass, some in terms of microbial ecology, others in terms of biological activity (measured as utilization rate of different substrate or end products generated). Numerous researchers have proposed batch bioassays to determine the activities of anaerobic culture in anaerobic ecosystems. The specific activity test also allows the prediction of maximal space loading rate, which can be applied during start-up procedures, and could be very useful for the selection of an adapted sludge for inoculation processes, for the detection of an unbalanced situation between several cultures in a reactor, for the calculation of the maximum organic load rate in a reactor, etc. However, all these papers report research are referred principally to biological activity tests in the mesophilic range of temperature, and no information is available for measuring acidogenic and methanogenic activity in the thermophilic range. The aim of this paper is to present the best conditions (methodology and procedures) for carrying out bath bioassays tests to determine acidogenic and methanogenic activity in thermophilic anaerobic reactors treating vinasses. (Author) 12 refs

  20. The Role of Oxygen in Anaerobic Microbiologically Influenced Marine Corrosion

    Science.gov (United States)

    2011-10-01

    02. A palladium catalyst inside the anaerobic chamber served as an 02 and H2 reaction site resulting in the formation of water and increased...CN and Suflita JM (in preparation), Anaerobic Metabolism of Biodiesel and Its Impact on Metal Corrosion. Page 7 of 7

  1. Xylan degradation by the anaerobic bacterium Bacteroides xylanolyticus

    NARCIS (Netherlands)

    Schyns, P.J.Y.M.L.

    1997-01-01

    Plant cell walls are the major reservoir of fixed carbon in nature. The mineralization of the fiber material, the so called lignocellulosic complex, proceeds almost exclusively by microbial processes in both aerobic and anaerobic environments. In anaerobic microbial processes the energy of

  2. Gender differences in anaerobic power in Nigerian students | Musa ...

    African Journals Online (AJOL)

    This study was undertaken in order to determine gender differences in anaerobic power of undergraduate physical education students. An attempt was also made to assess the relationship between selected anthropometric variables and indices of anaerobic power: peak power (PP), Mean power (MP), and fatigue index (FI) ...

  3. Solids removal in upflow anaerobic reactors, a review

    NARCIS (Netherlands)

    Mahmoud, N.; Zeeman, G.; Gijzen, H.J.; Lettinga, G.

    2003-01-01

    This desk study deals with the mechanisms and parameters affecting particles separation from wastewater in mainly upflow anaerobic reactors. Despite the fact that the functioning of upflow anaerobic sludge blanket (UASB) systems depends on both physical parameters and biological processes, the

  4. Molecular AND logic gate based on bacterial anaerobic respiration.

    Science.gov (United States)

    Arugula, Mary Anitha; Shroff, Namita; Katz, Evgeny; He, Zhen

    2012-10-21

    Enzyme coding genes that integrate information for anaerobic respiration in Shewanella oneidensis MR-1 were used as input for constructing an AND logic gate. The absence of one or both genes inhibited electrochemically-controlled anaerobic respiration, while wild type bacteria were capable of accepting electrons from an electrode for DMSO reduction.

  5. Performance of an innovative multi-stage anaerobic reactor during ...

    African Journals Online (AJOL)

    Start-up of an anaerobic reactor is a relatively delicate process and depends on various factors such as wastewater composition, available inoculum, operating conditions and reactor configuration. Accordingly, systematized operational procedures are important, mainly during the start-up of an anaerobic reactor.

  6. Optimisation Study on the Production of Anaerobic Digestate ...

    African Journals Online (AJOL)

    Organic fraction of municipal solid waste (OFMSW) is a rich substrate for biogas and compost production. Anaerobic Digestate compost (ADC) is an organic fertilizer produced from stabilized residuals of anaerobic digestion of OFMSW. This paper reports the result of studies carried out to optimise the production of ADC from ...

  7. Rumen derived anaerobic digestion of water hyacinth (Eicchornia ...

    African Journals Online (AJOL)

    Serial dilution was carried out and used to inoculate nutrient agar and chocolate agar. The agar plates were then incubated anaerobically at 37°C for 24 h. The digesters were seeded with rumen bacteria and immersed into water bath operated at 37°C. During the anaerobic digestion, volume of biogas produced was ...

  8. A fuzzy logic approach to control anaerobic digestion

    NARCIS (Netherlands)

    Domnanovich, A.M.; Strik, D.P.B.T.B.; Pfeiffer, B.; Karlovits, M.; Zani, L.; Braun, R.; Holubar, P.

    2003-01-01

    One of the goals of the EU-Project AMONCO (Advanced Prediction, Monitoring and Controlling of Anaerobic Digestion Process Behaviour towards Biogas Usage in Fuel Cells) is to create a control tool for the anaerobic digestion process, which predicts the volumetric organic loading rate (Bv) for the

  9. Anaerobic microbial processes for energy conservation and biotransformation of pollutants

    NARCIS (Netherlands)

    Luz Ferreira Martins Paulo, da Lara

    2017-01-01

    Anaerobic microbial processes are commonly applied in the treatment of domestic and industrial wastewaters. Anaerobic digestion (AD) of wastewater has received a great deal of attention, but many aspects related to the complex interactions between microorganism, and how that is affected by the

  10. Methanol conversion in high-rate anaerobic reactors

    NARCIS (Netherlands)

    Weijma, J.; Stams, A.J.M.

    2001-01-01

    An overview on methanol conversion in high-rate anaerobic reactors is presented, with the focus on technological as well as microbiological aspects. The simple C1-compound methanol can be degraded anaerobically in a complex way, in which methanogens, sulfate reducing bacteria and homoacetogens

  11. Control of calcium carbonate precipitation in anaerobic reactors

    NARCIS (Netherlands)

    Langerak, van E.P.A.

    1998-01-01

    Anaerobic treatment of waste waters with a high calcium content may lead to excessive precipitation of calcium carbonate. So far, no proper methods were available to predict or reduce the extent of precipitation in an anaerobic treatment system. Moreover, it also was not clear to what

  12. Moroccan rock phosphate solubilization during a thermo-anaerobic ...

    African Journals Online (AJOL)

    In order to investigate the presence of thermo-tolerant rock phosphate (RP) solubilizing anaerobic microbes during the fermentation process, we used grassland as sole organic substrate to evaluate the RP solubilization process under anaerobic thermophilic conditions. The result shows a significant decrease of pH from ...

  13. Partitioning the metabolic scope: the importance of anaerobic metabolism and implications for the oxygen- and capacity-limited thermal tolerance (OCLTT) hypothesis

    Science.gov (United States)

    Ejbye-Ernst, Rasmus; Michaelsen, Thomas Y.; Tirsgaard, Bjørn; Wilson, Jonathan M.; Jensen, Lasse F.; Steffensen, John F.; Pertoldi, Cino; Aarestrup, Kim; Svendsen, Jon C.

    2016-01-01

    Ongoing climate change is predicted to affect the distribution and abundance of aquatic ectotherms owing to increasing constraints on organismal physiology, in particular involving the metabolic scope (MS) available for performance and fitness. The oxygen- and capacity-limited thermal tolerance (OCLTT) hypothesis prescribes MS as an overarching benchmark for fitness-related performance and assumes that any anaerobic contribution within the MS is insignificant. The MS is typically derived from respirometry by subtracting standard metabolic rate from the maximal metabolic rate; however, the methodology rarely accounts for anaerobic metabolism within the MS. Using gilthead sea bream (Sparus aurata) and Trinidadian guppy (Poecilia reticulata), this study tested for trade-offs (i) between aerobic and anaerobic components of locomotor performance; and (ii) between the corresponding components of the MS. Data collection involved measuring oxygen consumption rate at increasing swimming speeds, using the gait transition from steady to unsteady (burst-assisted) swimming to detect the onset of anaerobic metabolism. Results provided evidence of the locomotor performance trade-off, but only in S. aurata. In contrast, both species revealed significant negative correlations between aerobic and anaerobic components of the MS, indicating a trade-off where both components of the MS cannot be optimized simultaneously. Importantly, the fraction of the MS influenced by anaerobic metabolism was on average 24.3 and 26.1% in S. aurata and P. reticulata, respectively. These data highlight the importance of taking anaerobic metabolism into account when assessing effects of environmental variation on the MS, because the fraction where anaerobic metabolism occurs is a poor indicator of sustainable aerobic performance. Our results suggest that without accounting for anaerobic metabolism within the MS, studies involving the OCLTT hypothesis could overestimate the metabolic scope available for

  14. Continuously-stirred Anaerobic Digester to Convert Organic Wastes into Biogas: System Setup and Basic Operation

    Science.gov (United States)

    Usack, Joseph G.; Spirito, Catherine M.; Angenent, Largus T.

    2012-01-01

    Anaerobic digestion (AD) is a bioprocess that is commonly used to convert complex organic wastes into a useful biogas with methane as the energy carrier 1-3. Increasingly, AD is being used in industrial, agricultural, and municipal waste(water) treatment applications 4,5. The use of AD technology allows plant operators to reduce waste disposal costs and offset energy utility expenses. In addition to treating organic wastes, energy crops are being converted into the energy carrier methane 6,7. As the application of AD technology broadens for the treatment of new substrates and co-substrate mixtures 8, so does the demand for a reliable testing methodology at the pilot- and laboratory-scale. Anaerobic digestion systems have a variety of configurations, including the continuously stirred tank reactor (CSTR), plug flow (PF), and anaerobic sequencing batch reactor (ASBR) configurations 9. The CSTR is frequently used in research due to its simplicity in design and operation, but also for its advantages in experimentation. Compared to other configurations, the CSTR provides greater uniformity of system parameters, such as temperature, mixing, chemical concentration, and substrate concentration. Ultimately, when designing a full-scale reactor, the optimum reactor configuration will depend on the character of a given substrate among many other nontechnical considerations. However, all configurations share fundamental design features and operating parameters that render the CSTR appropriate for most preliminary assessments. If researchers and engineers use an influent stream with relatively high concentrations of solids, then lab-scale bioreactor configurations cannot be fed continuously due to plugging problems of lab-scale pumps with solids or settling of solids in tubing. For that scenario with continuous mixing requirements, lab-scale bioreactors are fed periodically and we refer to such configurations as continuously stirred anaerobic digesters (CSADs). This article

  15. High-Intensity Intermittent Training Positively Affects Aerobic and Anaerobic Performance in Judo Athletes Independently of Exercise Mode.

    Science.gov (United States)

    Franchini, Emerson; Julio, Ursula F; Panissa, Valéria L G; Lira, Fábio S; Gerosa-Neto, José; Branco, Braulio H M

    2016-01-01

    The present study investigated the effects of high-intensity intermittent training (HIIT) on lower- and upper-body graded exercise and high-intensity intermittent exercise (HIIE, four Wingate bouts) performance, and on physiological and muscle damage markers responses in judo athletes. Thirty-five subjects were randomly allocated to a control group (n = 8) or to one of the following HIIT groups (n = 9 for each) and tested pre- and post-four weeks (2 training d·wk(-1)): (1) lower-body cycle-ergometer; (2) upper-body cycle-ergometer; (3) uchi-komi (judo technique entrance). All HIIT were constituted by two blocks of 10 sets of 20 s of all out effort interspersed by 10 s set intervals and 5-min between blocks. For the upper-body group there was an increase in maximal aerobic power in graded upper-body exercise test (12.3%). The lower-body group increased power at onset blood lactate in graded upper-body exercise test (22.1%). The uchi-komi group increased peak power in upper- (16.7%) and lower-body (8.5%), while the lower-body group increased lower-body mean power (14.2%) during the HIIE. There was a decrease in the delta blood lactate for the uchi-komi training group and in the third and fourth bouts for the upper-body training group. Training induced testosterone-cortisol ratio increased in the lower-body HIIE for the lower-body (14.9%) and uchi-komi (61.4%) training groups. Thus, short-duration low-volume HIIT added to regular judo training was able to increase upper-body aerobic power, lower- and upper-body HIIE performance.

  16. The anaerobic digestion of solid organic waste.

    Science.gov (United States)

    Khalid, Azeem; Arshad, Muhammad; Anjum, Muzammil; Mahmood, Tariq; Dawson, Lorna

    2011-08-01

    The accumulation of solid organic waste is thought to be reaching critical levels in almost all regions of the world. These organic wastes require to be managed in a sustainable way to avoid depletion of natural resources, minimize risk to human health, reduce environmental burdens and maintain an overall balance in the ecosystem. A number of methods are currently applied to the treatment and management of solid organic waste. This review focuses on the process of anaerobic digestion which is considered to be one of the most viable options for recycling the organic fraction of solid waste. This manuscript provides a broad overview of the digestibility and energy production (biogas) yield of a range of substrates and the digester configurations that achieve these yields. The involvement of a diverse array of microorganisms and effects of co-substrates and environmental factors on the efficiency of the process has been comprehensively addressed. The recent literature indicates that anaerobic digestion could be an appealing option for converting raw solid organic wastes into useful products such as biogas and other energy-rich compounds, which may play a critical role in meeting the world's ever-increasing energy requirements in the future. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. Treatment of slaughterhouse wastewaters using anaerobic filters.

    Science.gov (United States)

    Martinez, Sandra Luz; Torretta, Vincenzo; Minguelac, Jésus Vázquez; Siñeriz, Faustino; Raboni, Massimo; Copelli, Sabrina; Rada, Elena Cristina; Ragazzi, Marco

    2014-01-01

    In this paper, a laboratory-scale experimentation allowed comparing the performances of two upflow anaerobic packed-bed filters filled with different packing materials and operating at mesophilic conditions (30 degreeC) for treating slaughterhouse wastewaters. Methane production was experimentally evaluated considering different volumetric organic loading rates as well as feeding overloading conditions. Although filter performances declined with loading rates higher than 6 kg CODin m-3 d-1 , the chemical oxygen demand (COD) removal efficiency remained always above 60%. The experimental results allowed for determining kinetic parameters for bacterial growth rate and methane production, following Monod and Chen-Hashimoto models, respectively. Results demonstrated that the reactors reached a cellular retention time significantly greater than the hydraulic retention time. The kinetic parameter values (Ks, l/max) revealed the low microorganisms' affinity for the substrate and confirmed the moderate biodegradability of slaughterhouse wastewater. The kinetic analysis also allowed the comparison of the filters performances with another anaerobic system and the assessment of the parameters useful for real-scale plant design. The system design, applied to a medium-sized Argentinean slaughterhouse, demonstrated to (i) be energetically self-sufficient and (ii) contribute to the plant's water heating requirements.

  18. Anaerobic and aerobic transformation of TNT

    Energy Technology Data Exchange (ETDEWEB)

    Kulpa, C.F. [Univ. of Notre Dame, IN (United States). Dept. of Biological Sciences; Boopathy, R.; Manning, J. [Argonne National Lab., IL (United States). Environmental Research Div.

    1996-12-31

    Most studies on the microbial metabolism of nitroaromatic compounds have used pure cultures of aerobic microorganisms. In many cases, attempts to degrade nitroaromatics under aerobic conditions by pure cultures result in no mineralization and only superficial modifications of the structure. However, mixed culture systems properly operated result in the transformation of 2,4,6-trinitrotoluene (TNT) and in some cases mineralization of TNT occurs. In this paper, the mixed culture system is described with emphasis on intermediates and the characteristics of the aerobic microbial process including the necessity for a co-substrate. The possibility of removing TNT under aerobic/anoxic conditions is described in detail. Another option for the biodegradation of TNT and nitroaromatics is under anaerobic, sulfate reducing conditions. In this instance, the nitroaromatic compounds undergo a series of reductions with the formation of amino compounds. TNT under sulfate reducing conditions is reduced to triaminotoluene presumably by the enzyme nitrite reductase, which is commonly found in many Desulfovibrio spp. The removal of nitro groups from TNT is achieved by a series of reductive reactions with the formation of ammonia and toluene by Desulfovibrio sp. (B strain). These metabolic processes could be applied to other nitroaromatic compounds like nitrobenzene, nitrobenzoic acids, nitrophenols, and aniline. The data supporting the anaerobic transformation of TNT under different growth condition are reviewed in this report.

  19. Anaerobic Toxicity of Cationic Silver Nanoparticles | Science ...

    Science.gov (United States)

    The microbial toxicity of silver nanoparticles (AgNPs) stabilized with different capping agents was compared to that of Ag+ under anaerobic conditions. Three AgNPs were investigated: (1) negatively charged citrate-coated AgNPs (citrate-AgNPs), (2) minimally charged polyvinylpyrrolidone coated AgNPs (PVP-AgNps) and (3) positively charged branched polyethyleneimine coated AgNPs (BPEI-AgNPs). The AgNPs investigated in this experiment were similar in size (10-15 nm), spherical in shape, but varied in surface charge which ranged from highly negative to highly positive. While, at AgNPs concentrations lower than 5 mg L-1, the anaerobic decomposition process was not influenced by the presence of the nanoparticles, there was an observed impact on the diversity of the microbial community. At elevated concentrations (100 mg L-1 as silver), only the cationic BPEI-AgNPs demonstrated toxicity similar in magnitude to that of Ag+. Both citrate and PVP-AgNPs did not exhibit toxicity at the 100 mg L-1 as measured by biogas evolution. These findings further indicate the varying modes of action for nanoparticle toxicity and represent one of the few studies that evaluate end-of-life management concerns with regards to the increasing use of nanomaterials in our everyday life. These findings also highlight some of the concerns with a one size fits all approach to the evaluation of environmental health and safety concerns associated with the use of nanoparticles. The current

  20. The anaerobic threshold: over-valued or under-utilized? A novel concept to enhance lipid optimization!

    Science.gov (United States)

    Connolly, Declan A J

    2012-09-01

    The purpose of this article is to assess the value of the anaerobic threshold for use in clinical populations with the intent to improve exercise adaptations and outcomes. The anaerobic threshold is generally poorly understood, improperly used, and poorly measured. It is rarely used in clinical settings and often reserved for athletic performance testing. Increased exercise participation within both clinical and other less healthy populations has increased our attention to optimizing exercise outcomes. Of particular interest is the optimization of lipid metabolism during exercise in order to improve numerous conditions such as blood lipid profile, insulin sensitivity and secretion, and weight loss. Numerous authors report on the benefits of appropriate exercise intensity in optimizing outcomes even though regulation of intensity has proved difficult for many. Despite limited use, selected exercise physiology markers have considerable merit in exercise-intensity regulation. The anaerobic threshold, and other markers such as heart rate, may well provide a simple and valuable mechanism for regulating exercising intensity. The use of the anaerobic threshold and accurate target heart rate to regulate exercise intensity is a valuable approach that is under-utilized across populations. The measurement of the anaerobic threshold can be simplified to allow clients to use nonlaboratory measures, for example heart rate, in order to self-regulate exercise intensity and improve outcomes.