WorldWideScience

Sample records for windows showing daylighting

  1. Impact of three window configurations on daylight conditions

    DEFF Research Database (Denmark)

    Dubois, Marie-Claude; Sørensen, Karl Grau; Traberg-Borup, Steen

    The report describes the results of a pilot study on daylight conditions in simple rooms of residential buildings. As a tool for the analyses the Radiance Lighting Simulating System was used to simulate one room with three different window configurations, a vertical window, a dormer window......, and a roof window. The simulations were performed for overcast sky conditions and under one sunny sky, for two different times of the day. The study shows that the window configuration affects the daylight conditions (distribution and intensity) significantly. The roof window results in a higher (average......) daylight factor on a horizontal plane, i.e. more than twice as high compared with the vertical window, and more than triple as high compared with the dormer window....

  2. Effect of Window Glazing on Colour Quality of Transmitted Daylight

    Directory of Open Access Journals (Sweden)

    Rajendra Dangol

    2017-12-01

    Full Text Available In this study, the colour quality of the daylight transmitted through different window glazing types is evaluated. The analysis considered four different types of window glazing: laminated, monolithic, coated and applied film glazing ranging in luminous transmittance from around 0.97 to <0.1. The spectral transmittance data of different window glazing types are taken from the International Glazing Data Base (IGDB, which is maintained by Lawrence Berkeley National Laboratories (LBNL. The study showed that the CIE CRI does not always seem to be the suitable method to predict the colour quality of daylight in building for particular situations. However, in the context of this study, the prediction of colour rendering properties of window glazing by other metrics such as Colour Quality Scale (version 9, Memory CRI, Ra,D65 (adjusted CRI metric with D65 as the reference illuminant performed better. For most of the daylit situations inside the building, the chromaticity difference criterion was not met. Judging the colour quality of such situations requires different method.

  3. Effect of window glazing on colour quality of transmitted daylight

    NARCIS (Netherlands)

    Dangol, R.; Kruisselbrink, T.W.; Rosemann, A.L.P.

    2017-01-01

    In this study, the colour quality of the daylight transmitted through different window glazing types is evaluated. The analysis considered four different types of window glazing: laminated, monolithic, coated and applied film glazing ranging in luminous transmittance from around 0.97 to <0.1. The

  4. NOUR. Daylighting and thermal effects of windows in desert houses

    Energy Technology Data Exchange (ETDEWEB)

    Ouahrani, Djamel

    1999-07-01

    This study is on a combined effect of window, the daylighting and the thermal effects, in desert houses. It is comprised of two complementary studies. In the introduction a historical review on the development of using daylight has been carried out in order to place the case study in a historical perspective. The first study is comprehensive and contains two main parts. In the first part a study was carried out on the people and history of the town of Ghardaia in Southern Algeria. This was done in order to understand the architectural form of that region. The second part is experimental and consists of two field studies carried out in Ghardaia. Their aim was to investigate the influence of daylight and temperature on the use of residential houses. This investigation included both traditional and 'modern' houses, the modern having relatively large windows similar to those of the northern part of Algeria, the traditional ones having small or no windows. The second study is also experimental consisting of computer parametric studies on window design from two standpoints, namely daylighting level and thermal effects of windows in desert houses. A typical traditional house is described as it was observed. Then the recorded light values are presented and commented upon. In the second part, three types of modern houses observed in the field studies are presented and compared to the traditional archetype. The comparison especially dwells on the relative effectiveness of the two systems of daylighting. In the third part, focusing on various issues of lighting, the results of interviews with the inhabitants are presented. The historical studies indicate that the process of housing development, in several respects, has reached a certain quality (social, technology, and adaptation to climate) appropriate to the local original context, but that development has slowed down. The results of the lighting study indicate that the use of more windows in modern houses

  5. NOUR. Daylighting and thermal effects of windows in desert houses

    Energy Technology Data Exchange (ETDEWEB)

    Ouahrani, Djamel

    1999-07-01

    This study is on a combined effect of window, the daylighting and the thermal effects, in desert houses. It is comprised of two complementary studies. In the introduction a historical review on the development of using daylight has been carried out in order to place the case study in a historical perspective. The first study is comprehensive and contains two main parts. In the first part a study was carried out on the people and history of the town of Ghardaia in Southern Algeria. This was done in order to understand the architectural form of that region. The second part is experimental and consists of two field studies carried out in Ghardaia. Their aim was to investigate the influence of daylight and temperature on the use of residential houses. This investigation included both traditional and 'modern' houses, the modern having relatively large windows similar to those of the northern part of Algeria, the traditional ones having small or no windows. The second study is also experimental consisting of computer parametric studies on window design from two standpoints, namely daylighting level and thermal effects of windows in desert houses. A typical traditional house is described as it was observed. Then the recorded light values are presented and commented upon. In the second part, three types of modern houses observed in the field studies are presented and compared to the traditional archetype. The comparison especially dwells on the relative effectiveness of the two systems of daylighting. In the third part, focusing on various issues of lighting, the results of interviews with the inhabitants are presented. The historical studies indicate that the process of housing development, in several respects, has reached a certain quality (social, technology, and adaptation to climate) appropriate to the local original context, but that development has slowed down. The results of the lighting study indicate that the use of more windows in modern houses constitutes a

  6. Window design : visual and thermal consequences : analysis of the thermal and daylighting performance of windows

    NARCIS (Netherlands)

    Bergem-Jansen, P.M. van; Soeleman, R.S.

    1979-01-01

    Selected results of an analysis for the thermal and lighting requirements associated with windows in utility buildings are presented. This analysis concerns the effects of r¡indow size and shape, orientation and of different ways of supplementing the daylight by artifieial light for a typical office

  7. Energy-efficient window systems. Effects on energy use and daylight in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Buelow-Huebe, H.

    2001-11-01

    This thesis deals with energy-efficient windows in Swedish buildings. Parametric studies were performed in the dynamic energy simulation tool Derob-LTH in order to study the effects of window choices on energy use and indoor climate for both residential and office buildings. A steady-state program was used to evaluate two years of measurements of energy use and indoor temperatures of an energy-efficient row-house. Two behavioural studies regarding (1) daylight transmittance, view and room perception using super-insulated windows and (2) the satisfaction with the daylight environment and the use of shading devices in response to daylight/sunlight were conducted in full-scale laboratory environments exposed to the natural climate. Results show that as the energy-efficiency of buildings increase, window U-values must decrease in order not to increase the annual heating demand, since the heating season is shortened, and useful solar gains become smaller. For single-family houses with a window-to-floor area ratio of 15 % and insulated according the current Swedish building code, the U-values should thus on average be lower than 1.0 W/m{sup 2}K. For houses insulated according to 1960s standard, the U-value may on average be 1.6 W/m{sup 2}K. For colder climates (northern Sweden), the U-values should be somewhat lower, while slightly higher U-values can be tolerated in milder climates of south Sweden. Thermal comfort during winter is improved for energy-efficient windows. However, overheating problems exist for both super-insulated houses and highly glazed office buildings showing a need for very low U-values in combination with low g-values. Daylight experiments indicate that the use of two low-emittance coatings tints the transmitted daylight enough to be appreciated, and colours may be perceived as more drab and rooms more enclosed. A compromise between energy-efficiency and daylighting may be needed, and it is suggested that only one coating be used except when very

  8. Comparative Study of Two Daylighting Analysis Methods with Regard to Window Orientation and Interior Wall Reflectance

    Directory of Open Access Journals (Sweden)

    Yeo Beom Yoon

    2014-09-01

    Full Text Available The accuracy and speed of the daylighting analysis developed for use in EnergyPlus is better than its predecessors. In EnergyPlus, the detailed method uses the Split-flux algorithm whereas the DElight method uses the Radiosity algorithm. Many existing studies have addressed the two methods, either individually or compared with other daylight analysis methods like Ray tracing but still there is lack of detailed comparative study of these two methods. Our previous studies show that the Split-flux method overestimates the illuminance, especially for the areas away from the window. The Radiosity method has the advantage of accurately predicting this illuminance because of how it deals with the diffuse light. For this study, the EnergyPlus model, which has been calibrated using data measured in a real building in previous studies, has also been used. The calibrated model has a south oriented window only. This model is then used to analyze the interior illuminance inside the room for north, west and east orientation of the window by rotating the model and by changing the wall reflectance of the model with south oriented window. Direct and diffuse component of the illuminance as well as the algorithms have been compared for a detailed analysis.

  9. Window Material Daylighting Performance Assessment Algorithm: Comparing Radiosity and Split-Flux Methods

    Directory of Open Access Journals (Sweden)

    Yeo Beom Yoon

    2014-04-01

    Full Text Available Windows are the primary aperture to introduce solar radiation to the interior space of a building. This experiment explores the use of EnergyPlus software for analyzing the illuminance level on the floor of a room with reference to its distance from the window. For this experiment, a double clear glass window has been used. The preliminary modelling in EnergyPlus showed a consistent result with the experimentally monitored data in real time. EnergyPlus has two mainly used daylighting algorithms: DElight method employing radiosity technique and Detailed method employing split-flux technique. Further analysis for illuminance using DElight and Detailed methods showed significant difference in the results. Finally, we compared the algorithms of the two analysis methods in EnergyPlus.

  10. The impact of windows and daylight on acute-care nurses' physiological, psychological, and behavioral health.

    Science.gov (United States)

    Zadeh, Rana Sagha; Shepley, Mardelle McCuskey; Williams, Gary; Chung, Susan Sung Eun

    2014-01-01

    To investigate the physiological and psychological effects of windows and daylight on registered nurses. To date, evidence has indicated that appropriate environmental lighting with characteristics similar to natural light can improve mood, alertness, and performance. The restorative effects of windows also have been documented. Hospital workspaces generally lack windows and daylight, and the impact of the lack of windows and daylight on healthcare employees' well being has not been thoroughly investigated. Data were collected using multiple methods with a quasi-experimental approach (i.e., biological measurements, behavioral mapping, and analysis of archival data) in an acute-care nursing unit with two wards that have similar environmental and organizational conditions, and similar patient populations and acuity, but different availability of windows in the nursing stations. Findings indicated that blood pressure (p windows and daylight. A possible micro-restorative effect of windows and daylight may result in lowered blood pressure and increased oxygen saturation and a positive effect on circadian rhythms (as suggested by body temperature) and morning sleepiness. Critical care/intensive care, lighting, nursing, quality care, work environment.

  11. Impact of façade window design on energy, daylighting and thermal comfort in nearly zero-energy houses

    DEFF Research Database (Denmark)

    Vanhoutteghem, Lies; Skarning, Gunnlaug Cecilie Jensen; Hviid, Christian Anker

    2015-01-01

    a solution space defined by targets for daylighting and thermal comfort. In contrast with existing guidelines, the results show an upper limit for energy savings and utilisation of solar gains in south-oriented rooms. Instead, low U-values are needed in both north- and south oriented rooms before large......Appropriate window solutions are decisive for the design of 'nearly zero-energy' buildings with healthy and comfortable indoor environment. This paper focuses on the relationship between size, orientation and glazing properties of façade windows for different side-lit room geometries in Danish...... 'nearly zero-energy' houses. The effect of these parameters on space heating demand, daylighting and thermal environment is evaluated by means of EnergyPlus and DAYSIM and presented in charts illustrating how combinations of design parameters with minimum space heating demand can be selected within...

  12. Dynamic window daylighting systems: electropolymeric technology for solar responsive building envelopes

    Science.gov (United States)

    Krietemeyer, Elizabeth A.; Smith, Shane I.; Dyson, Anna H.

    2011-04-01

    Human health and energy problems associated with the lack of control of sunlight in contemporary buildings have necessitated research into dynamic windows for energy efficient buildings. Existing window technologies have made moderate progress towards greater energy performance for facades but remain limited in their response to dynamic solar conditions, building energy requirements, and variable user preferences for visual comfort. Recent developments in electropolymeric display technology provide opportunities to transfer electroactive polymers to windows that can achieve high levels of geometric and spectral selectivity through the building envelope in order to meet the lighting, thermal and user requirements of occupied spaces. Experimental simulations that investigate daylight quality, energy performance, and architectural effects of electropolymeric glazing technology are presented.

  13. Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office testbed

    Energy Technology Data Exchange (ETDEWEB)

    Thanachareonkit, Anothai; Lee, Eleanor S.; McNeil, Andrew

    2013-08-31

    Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Microstructured prismatic window films can be manufactured using low-cost, roll-to-roll fabrication methods and adhered to the inside surface of existing windows as a retrofit measure or installed as a replacement insulating glass unit in the clerestory portion of the window wall. A clear film patterned with linear, 50-250 micrometer high, four-sided asymmetrical prisms was fabricated and installed in the south-facing, clerestory low-e, clear glazed windows of a full-scale testbed facility. Views through the film were distorted. The film was evaluated in a sunny climate over a two-year period to gauge daylighting and visual comfort performance. The daylighting aperture was small (window-towall ratio of 0.18) and the lower windows were blocked off to isolate the evaluation to the window film. Workplane illuminance measurements were made in the 4.6 m (15 ft) deep room furnished as a private office. Analysis of discomfort glare was conducted using high dynamic range imaging coupled with the evalglare software tool, which computes the daylight glare probability and other metrics used to evaluate visual discomfort. The window film was found to result in perceptible levels of discomfort glare on clear sunny days from the most conservative view point in the rear of the room looking toward the window. Daylight illuminance levels at the rear of the room were significantly increased above the reference window condition, which was defined as the same glazed clerestory window but with an interior Venetian blind (slat angle set to the cut-off angle), for the equinox to winter solstice period on clear sunny days. For partly cloudy and overcast sky conditions, daylight levels were improved slightly. To reduce glare, the daylighting film was coupled with a diffusing film in an insulating glazing unit. The diffusing film retained the directionality of the

  14. Demonstration with Energy and Daylighting Assessment of Sunlight Responsive Thermochromic (SRT) Window Systems

    Energy Technology Data Exchange (ETDEWEB)

    Broekhuis, Michael; Liposcak, Curtis; Witte, Michael; Henninger, Robert; Zhou, Xiaohui; Petzen, George; Buchanan, Michael; Kumar, Sneh

    2012-03-31

    Pleotint, LLC was able to successfully extrude thermochromic interlayer for use in the fenestration industry. Pleotint has developed a thermochromic sytem that requires two thermochromic colors to make a neutral color when in the tinted state. These two colors were assembled into a single interlayer called a tri-layer prelam by Crown Operations for use in the glass lamination industry. Various locations, orientations, and constructions of thermochromic windows were studied with funds from this contract. Locations included Australia, California, Costa Rica, Indiana, Iowa, Mexico. Installed orientations included vertical and skylight glazing applications. Various constructions included monolithic, double pane, triple pane constructions. A daylighting study was conducted at LinEl Signature. LinEl Signature has a conference room with a sylight roof system that has a west orientation. The existing LinEl Signature conference room had constant tint 40% VLT transparent skylights. Irradiance meters were installed on the interior and exterior sides of a constant tint skylight. After a month and a half of data collection, the irradiance meters were removed and the constant tint skylights were replaced with Pleotint thermochromic skylight windows. The irradiance meters were reinstalled in the same locations and irradiance data was collected. Both data sets were compared. The data showed that there was a linear relationship with exterior and interior irradiance for the existing constant tint skylights. The thermochromic skylights have a non-linear relationship. The thermochromic skylights were able to limit the amount of irradiance that passed through the thermochromic skylight. A second study of the LinEl Signature conference was performed using EnergyPlus to calculate the amount of Illuminance that passed through constant tint skylights as compared to thermochromic skylights. The constant tint skylights transmitted Illuminance is 2.8 times higher than the thermochromic

  15. Photoageing of Baltic amber-influence of daylight radiation behind window glass on surface colour and chemistry

    DEFF Research Database (Denmark)

    Shashoua, Yvonne

    2011-01-01

    The aim of this study was to provide evidence about the interaction between Baltic amber and daylight behind window glass, essential to understanding the mechanisms by which the material degrades in museum environments and to propose techniques for preventive conservation based on the control...

  16. Thermal and Daylighting Performance of Energy-Efficient Windows in Highly Glazed Residential Buildings: Case Study in Korea

    Directory of Open Access Journals (Sweden)

    Chang Heon Cheong

    2014-10-01

    Full Text Available Cooling load in highly glazed residential building can be excessively large due to uncontrolled solar energy entering the indoor space. This study focuses on the cooling load reduction and changes in the daylighting properties via the application of a double window system (DWS with shading with various surface reflectivities in highly glazed residential buildings. Evaluation of thermal and daylighting performances is carried out using simulation tools. The reductions in cooling load and energy cost through the use of DWS are evaluated through a comparative simulation considering conventional windows: a single window and a double window. Three variables of window types, natural ventilation, and shading reflectivity are reflected in the study. According to our results, implementation of DWS reduced cooling load by 43%–61%. Electricity cost during the cooling period was reduced by a maximum of 24%. However, a shading device setting that prioritizes effective cooling load reduction can greatly decrease the daylighting factor and luminance level of indoor space. A DWS implementing shading device with highly reflective at all surfaces is appropriate option for the more comfortable thermal and visual environment, while a shading device with low reflectivity at rear of the surface can contribute an additional 4% cooling load reduction.

  17. Designing with daylight; the relationship between daylight and health

    DEFF Research Database (Denmark)

    Hauge, Bettina

    2015-01-01

    and the significance of daylight. This paper describes the views and significance of daylight to people in their everyday lives. Based on a qualitative research project in Denmark about the use of windows, performed from May to August 2012 among 13 families , using in-depth interviews, observations, photos...... and postcards for storytelling, I will show how daylight is perceived, used, coped with, and negotiated by these people in their homes, thus exploring the social character of a natural phenomenon. A metaphor will be used from biomimetics (Benyus 1997), claiming that the Danish people, like plants, need daylight....... With the concept of ‘dwelling’ (Ingold 2000), which implies that people engage in their environment and create possibilities for dwelling at home to feel comfortable and at home in the world, I illustrate people’s day-to-day entanglements with daylight and highlight the social qualities of daylight. The paper...

  18. Lighting energy savings potential of split-pane electrochromic windows controlled for daylighting with visual comfort

    Energy Technology Data Exchange (ETDEWEB)

    Software, Anyhere; Fernandes, Luis; Lee, Eleanor; Ward, Greg

    2013-03-15

    A simulation study was conducted to evaluate lighting energy savings of split-pane electrochromic (EC) windows controlled to satisfy key visual comfort parameters. Using the Radiance lighting simulation software, interior illuminance and luminance levels were computed for a south-facing private office illuminated by a window split into two independently-controlled EC panes. The transmittance of these was optimized hourly for a workplane illuminance target while meeting visual comfort constraints, using a least-squares algorithm with linear inequality constraints. Blinds were successively deployed until visual comfort criteria were satisfied. The energy performance of electrochromics proved to be highly dependent on how blinds were controlled. With hourly blind position adjustments, electrochromics showed significantly higher (62percent and 53percent, respectively without and with overhang) lighting energy consumption than clear glass. With a control algorithm designed to better approximate realistic manual control by an occupant, electrochromics achieved significant savings (48percent and 37percent, respectively without and with overhang). In all cases, energy consumption decreased when the workplace illuminance target was increased. In addition, the fraction of time during which the occupant had an unobstructed view of the outside was significantly greater with electrochromics: 10 months out of the year versus a handful of days for the reference case.

  19. Impact of windows and daylight exposure on overall health and sleep quality of office workers: a case-control pilot study.

    Science.gov (United States)

    Boubekri, Mohamed; Cheung, Ivy N; Reid, Kathryn J; Wang, Chia-Hui; Zee, Phyllis C

    2014-06-15

    This research examined the impact of daylight exposure on the health of office workers from the perspective of subjective well-being and sleep quality as well as actigraphy measures of light exposure, activity, and sleep-wake patterns. Participants (N = 49) included 27 workers working in windowless environments and 22 comparable workers in workplaces with significantly more daylight. Windowless environment is defined as one without any windows or one where workstations were far away from windows and without any exposure to daylight. Well-being of the office workers was measured by Short Form-36 (SF-36), while sleep quality was measured by Pittsburgh Sleep Quality Index (PSQI). In addition, a subset of participants (N = 21; 10 workers in windowless environments and 11 workers in workplaces with windows) had actigraphy recordings to measure light exposure, activity, and sleep-wake patterns. Workers in windowless environments reported poorer scores than their counterparts on two SF-36 dimensions--role limitation due to physical problems and vitality--as well as poorer overall sleep quality from the global PSQI score and the sleep disturbances component of the PSQI. Compared to the group without windows, workers with windows at the workplace had more light exposure during the workweek, a trend toward more physical activity, and longer sleep duration as measured by actigraphy. We suggest that architectural design of office environments should place more emphasis on sufficient daylight exposure of the workers in order to promote office workers' health and well-being.

  20. Capturing the Daylight Dividend

    Energy Technology Data Exchange (ETDEWEB)

    Peter Boyce; Claudia Hunter; Owen Howlett

    2006-04-30

    Capturing the Daylight Dividend conducted activities to build market demand for daylight as a means of improving indoor environmental quality, overcoming technological barriers to effective daylighting, and informing and assisting state and regional market transformation and resource acquisition program implementation efforts. The program clarified the benefits of daylight by examining whole building systems energy interactions between windows, lighting, heating, and air conditioning in daylit buildings, and daylighting's effect on the human circadian system and productivity. The project undertook work to advance photosensors, dimming systems, and ballasts, and provided technical training in specifying and operating daylighting controls in buildings. Future daylighting work is recommended in metric development, technology development, testing, training, education, and outreach.

  1. Daylight Redirecting Window Films

    Science.gov (United States)

    2013-09-01

    28 4.1.3 Fort Bliss , TX .......................................................................................29 4.1.4 Marine Corps Air Ground...Norfolk; Shawn Bogdan, Matt Siler and Kyle Hess at Naval War College, Newport; Marisela Leyva at Fort Bliss , TX; Clovis Vaughn and Andrew Burton at...team at Heschong Mahone Group (now part of TRC Companies): Lisa Heschong, Abhijeet Pande, Mudit Agarwal and Tim Perry for their immense contribution

  2. Daylight Redirecting Window Film

    Science.gov (United States)

    2013-12-01

    Fort Bliss , TX; Clovis Vaughn and Andrew Burton at 29 Palms, CA; Doug Taber at Naval Post Graduate School (NPS), Monterey; and Mitch Hailey at Naval...Agarwal and Tim Perry for their immense contribution to this project. Finally, throughout the project, the guidance and counseling of Vern Novstrup at...and control) VA Norfolk Z-133 1 1 1 6 72 48 120 CA 29 Palms 1416 5 7 14 13 108 31 62 RI Newport Hewitt Hall 2 5 9 19 88 24 40 TX Fort Bliss

  3. Daylight calculations in practice

    DEFF Research Database (Denmark)

    Iversen, Anne; Roy, Nicolas; Hvass, Mette

    The aim of the project was to obtain a better understanding of what daylight calculations show and also to gain knowledge of how the different daylight simulation programs perform compared with each other. Experience has shown that results for the same room, obtained from two daylight simulation...... programs can give different results. This can be due to restrictions in the program itself and/or be due to the skills of the persons setting up the models. This is crucial as daylight calculations are used to document that the demands and recommendations to daylight levels outlined by building authorities....... The aim of the project was to obtain a better understanding of what daylight calculations show and also to gain knowledge of how the different daylight simulation programs perform compared with each other. Furthermore the aim was to provide knowledge of how to build up the 3D models that were...

  4. Windows

    DEFF Research Database (Denmark)

    Heiselberg, Per; Svidt, Kjeld; Nielsen, Peter V.

    In natural ventilation systems fresh air is often provided through opening of windows. However, the knowledge of the performance of windows is rather limited. Computation of natural ventilation air flow through windows is most commonly made using discharge coefficients, that are regarded as being...... constant. The reported results show that the discharge coefficient for a window opening cannot be regarded as a constant and that it varies considerably with the size of the opening area, the window type and the temperature difference. Therefore, the use of a constant value can lead to serious errors...

  5. Daylight Science and Daylighting Technology

    CERN Document Server

    Kittler, Richard; Darula, Stanislav

    2012-01-01

    Sunlight profoundly influences the Earth's atmosphere and biosphere. Nature fuels the evolution of all living things, their visual systems, and the manner in which they adapt, accommodate, and habituate. Sun luminance measurements serve as data to calculate typical changes in the daily, monthly, and annual variability characteristics of daylight. Climate-based sky luminance patterns are used as models in predicting daylighting calculation and computer programs applied in architecture and building design. Historically, daylight science and daylighting technology has prioritized photometric methods of measurements, calculation, and graphical tools aimed at predicting or evaluating the daylighting of architectural design alternatives. However, due to a heightened awareness of general health and well-being, sunlight exposure and freedom from visual discomfort while undertaking visual tasks are now equally prioritized. Therefore, in order to assure optimal environmental quality, daylighting technology must be base...

  6. Workplane Illuminance Estimation for Robust Daylight Harvesting Lighting Control

    NARCIS (Netherlands)

    Zhang, S.; Birru, D.

    2012-01-01

    Daylight harvesting lighting controls can provide significant energysavings in daylit spaces. However, their performance is affected bythe changing lighting distribution in the space due to window treatments and the sun. Such impacts reduce the field performance of daylight harvesting dimming

  7. Color tuning in alert macaque V1 assessed with fMRI and single-unit recording shows a bias toward daylight colors.

    Science.gov (United States)

    Lafer-Sousa, Rosa; Liu, Yang O; Lafer-Sousa, Luis; Wiest, Michael C; Conway, Bevil R

    2012-05-01

    Colors defined by the two intermediate directions in color space, "orange-cyan" and "lime-magenta," elicit the same spatiotemporal average response from the two cardinal chromatic channels in the lateral geniculate nucleus (LGN). While we found LGN functional magnetic resonance imaging (fMRI) responses to these pairs of colors were statistically indistinguishable, primary visual cortex (V1) fMRI responses were stronger to orange-cyan. Moreover, linear combinations of single-cell responses to cone-isolating stimuli of V1 cone-opponent cells also yielded stronger predicted responses to orange-cyan over lime-magenta, suggesting these neurons underlie the fMRI result. These observations are consistent with the hypothesis that V1 recombines LGN signals into "higher-order" mechanisms tuned to noncardinal color directions. In light of work showing that natural images and daylight samples are biased toward orange-cyan, our findings further suggest that V1 is adapted to daylight. V1, especially double-opponent cells, may function to extract spatial information from color boundaries correlated with scene-structure cues, such as shadows lit by ambient blue sky juxtaposed with surfaces reflecting sunshine. © 2012 Optical Society of America

  8. Tips for daylighting with windows

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, Alastair [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Selkowitz, Stephen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2013-10-01

    These guidelines provide an integrated approach to the cost-effective design of perimeter zones in new commercial buildings and existing building retrofits. They function as a quick reference for building designers, through a set of easy steps and rules-of-thumb, emphasizing “how-to” practical details. References are given to more detailed sources of information, should the reader wish to go further. The design method used in this document emphasizes that building decisions should be made within the context of the whole building as a single functioning system rather than as an assembly of distinct parts. This integrated design approach looks at the ramifications of each individual system decision on the whole building. For example, the decision on glazing selection will have an effect on lighting, mechanical systems, and interior design. Therefore, the entire design team should participate and influence this glazing decision—which typically rests with the architect alone. The benefit of an integrated design approach is a greater chance of success towards long-term comfort and sustained energy savings in the building.

  9. Assessment of daylight quality in simple rooms

    DEFF Research Database (Denmark)

    Johnsen, Kjeld; Dubois, Marie-Claude; Sørensen, Karl Grau

    The present report documents the results of a study on daylight conditions in simple rooms of residential buildings. The overall objective of the study was to develop a basis for a method for the assessment of daylight quality in a room with simple geometry and window configurations. As a tool...... in daylighting conditions for a number of lighting parameters. The results gave clear indications of, for instance, which room would be the brightest, under which conditions might glare be a problem and which type of window would yield the greatest luminous variation (or visual interest), etc....

  10. Combining annual daylight simulation with photobiology data to assess the relative circadian efficacy of interior spaces

    Energy Technology Data Exchange (ETDEWEB)

    Pechacek, C.S.; Andersen, M. [Massachusetts Inst. of Technology, Cambridge, MA (United States). Dept. of Architecture, Building Technology; Lockley, S.W. [Harvard Medical School, Boston, MA (United States). Div. of Sleep Medicine, Brigham and Women' s Hospital

    2008-07-01

    This paper addressed the issue of hospital design and the role of daylight in patient health care. It presented a new approach for integrating empirical data and findings in photobiology into the performance assessment of a space, thus combining both visual and health-related criteria. Previous studies have reported significant health care outcomes in daylit environments, although the mechanism and photoreceptor systems controlling these effects remain unknown. This study focused on furthering the previous studies beyond windows to describing the characteristics of daylight that may promote human health by providing daylighting for the appropriate synchronization of circadian rhythms, and then make specific daylighting recommendations, grounded in biological findings. In particular, this study investigated the use of daylight autonomy (DA) to simulate the probabilistic and temporal potential of daylight for human health needs. Results of photobiology research were used to define threshold values for lighting, which were then used as goals for simulations. These goals included spectrum, intensity and timing of light at the human eye. The study investigated the variability of key architectural decisions in hospital room design to determine their influence on achieving the goals. The simulations showed how choices in building orientation, window size, user-window position and interior finishes affect the circadian efficacy of a space. Design decisions can improve or degrade the health potential for the space considered. While the findings in this research were specific to hospitals, the results can be applied to other building types such as office buildings and residences. 33 refs., 7 figs.

  11. Adaptive integration of daylight and artificial lighting

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve

    2016-01-01

    Daylight is dynamic and dependent upon weather conditions; unfolding with both subtle and dramatic variations in qualities of light. Through a building’s apertures, daylight creates a connection between the space inside and the world outside. The aperture or window itself constitutes the frame...... with the world. In contrast to fluctuating daylight, a specific distinctive feature of artificial light has been – until very recently – its constancy in colour and intensity. However, by virtue of the technological convertibility of LEDs in concert with digital control systems, LEDs are capable of dynamically...... producing variations in colour and intensity in ways that correspond to our experiences of the daylight. Daylight and artificial lighting are thus positioned in a new relationship to one another. Metaphorically, one can think of the adaptive software as ‘digital weather’ – as a self-generating and shifting...

  12. A review of daylight illuminance determinations and energy implications

    Energy Technology Data Exchange (ETDEWEB)

    Li, Danny H.W. [Building Energy Research Group, Department of Building and Construction, City University of Hong Kong, Tat Chee Avenue, Kowloon, Hong Kong SAR (China)

    2010-07-15

    Daylighting is recognized as an important element in architecture and a useful strategy in energy-efficient building designs. Daylight gives a sense of cheeriness and brightness that can have a significant positive impact on the people. There is a scope for integrating daylight with electric light to reduce building energy use. The amount of daylight entering a building is mainly through window openings, which create in the indoor environment a more attractive and pleasing atmosphere, in addition to maximise visual access to the pleasant views of the outside world. Determinations of the exterior and interior daylight and lighting energy savings are key issues to demonstrate the benefits based on daylighting designs. This paper provides a review of daylight illuminance determinations and the lighting energy reductions due to daylighting schemes. The study includes daylight measurements, prediction of daylight illuminance under various sky conditions and potential electric lighting energy savings from daylight-linked lighting controls. The article aims at providing building professionals, practitioners and researchers more information and a better understanding of daylight for promoting effective daylighting designs and evaluations. (author)

  13. Light and energy - daylight measurements

    Energy Technology Data Exchange (ETDEWEB)

    Christoffersen, Jens; Logadottir, A.; Traberg-Borup, S.; Barrie-Nielsen, K.

    2009-07-01

    All measurements where conducted in the spring of 2007, except the Interpane panel. The solar cell panels have been evaluated by three performance indicators to assess the daylight quantity within the room and the systems ability to maintain view to the outside. In the study, we used two performance indicators to assess the daylight quantity within the room: 1. the daylight factor (overcast sky) 2. the relative work plane illuminance (clear sky condition) Overcast sky: In general, all panels provided less daylight than the recommended requirement in the Danish Building Regulation of 2% on the work plane. This will most likely result in additional need for electric lighting. However, larger window areas and more parts of the facade with clear unobstructed glass may be one solution. Clear sky: In general, all panels provided less interior light levels than the two reference systems in the back of the room. Almost all systems aloud more or less direct sunlight in the window perimeter through the clear openings and additional needs for some kind of shading device is to be expected. Some systems blocked a large portion of the light in the majority of the room, and additional electric light in this part of the room may be needed. Only one performance indicator where used to describe the quality of the panels. View: In general, all panels, except two, obstruct the view significantly and cause figure/background confusion for a view position close to the window and the discrepancies of colour judgements. Only two systems provided a fairly clear view to the outside without to much distortion of the view. (au)

  14. Advanced fenestration and daylighting systems

    Energy Technology Data Exchange (ETDEWEB)

    McCluney, R. [Florida Solar Energy Centere, Cocoa, FL (United States)

    1998-09-01

    Advanced fenestration systems are new high-performance glazing and reflecting systems for otherwise conventional windows which offer specialized spectral and /or angular selectivity to provide improved illumination quantity and quality under optimal human comfort and energy conservation conditions. Advanced daylighting systems include systems manufactured by the solar lighting industry to introduce daylight into the core spaces of multi-storey buildings, spaces distant from the building envelope, or other locations where more conventional daylighting apertures cannot be placed. Details of operating, energy and illumination performance characteristics of both these systems were provided. It was concluded that solar lighting systems can effectively provide daylight illumination to interior spaces of a building that are not amenable to more conventional systems. Nevertheless, techniques need to be developed to predict the performance of such systems prior to their being built, so as to provide designers better means for justifying their use and economic viability, and to develop codes and performance standards to protect the consumer in the marketplace. 20 refs., 12 figs.

  15. Windows with improved energy performances

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    2003-01-01

    Heat loss through windows represents a considerable part of the total heat loss from houses. However, apart from providing daylight access and view, windows offer a unique potential for solar gain to be exploited during the heating season. Until now valuation of the energy performance of windows...... has primary focused on the heat loss coefficient, U-value. However, as the U-value, especially for the glazing part, has improved considerably during the last years, the total solar energy transmittance, g-value, has become equally important to the total energy performance of windows. Improved energy...... resulted in a window with a positive net energy gain (in short the Net Gain Window), which means that it contributes to the space heating of the building. All improvements are based on existing technology and manufacturing methods. The results from this work show that the energy performances of windows can...

  16. Impacts of orientation on daylighting in high-rise office buildings in Malaysia

    Directory of Open Access Journals (Sweden)

    AbdolHamid Mahdavi

    2015-12-01

    Full Text Available Orientation is one of the important factors in building design to use daylight and ‎conserve energy. Well-orientated buildings maximise daylight reception through ‎building facades and reduce the need for artificial lighting. Reasonable daylighting usage in office buildings is an important part of an architect’s designing process, which leads to lesser electricity consumption as well as providing a visual and thermal comfort for the occupants. Orientation is an important factor in passive design strategies. This paper focuses on the orientation effect on daylighting into office rooms. The research method of this study was simulation which is performed on a hypothetical model on a 25 storey high-rise office building in Malaysia. All simulations were carried out in the IES-VE software that uses RADIANCE program for illuminance calculations. To evaluate the daylight in various conditions, a new index SAZ was introduced which assesses daylight factor (DF and absolute Lux. Results showed similar SAZ in CIE overcast sky in various orientations; whereas, in sunny sky due to sun path in Malaysia, different results showed northern and southern rooms have the best illuminance distribution. However, the similar window form and size in four orientations lead to more energy consumption for artificial lighting and cooling loads.

  17. Balancing energy and daylighting performances for envelope design: A new index and proposition of a case study in Hong Kong

    International Nuclear Information System (INIS)

    Xie, Jing Chao; Xue, Peng; Mak, Cheuk Ming; Liu, Jia Ping

    2017-01-01

    Highlights: •Daylighting and energy performances were studied simultaneously. •Energy demands of lighting and air-conditioning systems were both included. •Luminous comfort was quantified by Ave. DA 300 with the range from 29.6% to 57.8%. •Energy Daylight Rate was proposed as a simple multi-objective optimization approach. •Optimal scenarios for all directions were tested and chosen by EDR method. -- Abstract: Being healthy and energy saving have become two important principles of building development. Daylight is an influential factor with the characteristics of both photometry and radiometry. Irradiance brings solar heat gains that transfer to building cooling load, while illuminance provides a luminous environment and affects artificial lighting system at the same time. To balance the energy and daylighting performances, it is reasonable to minimize the environmental load under moderate comfort conditions. This study first quantified luminous comfort with a dynamic daylighting metric, average daylight autonomy (Ave. DA 300 ), from a questionnaire survey and simulation work. The benchmark of this metric should range from 29.6% to 57.8% for high-rise residential buildings. With this guideline, the Hong Kong public housing units is found that part of units lack of daylight due to the high building floor and density, while some units have potential to save energy by compromising daylighting performance. Therefore, a new index, energy daylight rate (EDR), is proposed to help decide the best scenario of envelope design for both daylighting and shading purposes. The results show that opening a secondary window is an efficient way to bring more light in and lengthening overhang is an efficient way to block excessive sunlight. This method and the new index are proved to have the ability to help defining proper building envelope design at the early stage.

  18. Daylighting performance evaluation of a bottom-up motorized roller shade

    Energy Technology Data Exchange (ETDEWEB)

    Kapsis, K.; Athienitis, A.K.; Zmeureanu, R.G. [Department of Building, Civil and Environmental Engineering, Concordia University, Montreal, QC (Canada); Tzempelikos, A. [School of Civil Engineering, Purdue University, West Lafayette, IN (United States)

    2010-12-15

    This paper presents an experimental and simulation study for quantifying the daylighting performance of bottom-up roller shades installed in office spaces. The bottom-up shade is a motorized roller shade that opens from top to bottom operating in the opposite direction of a conventional roller shade, so as to cover the bottom part of the window, while allowing daylight to enter from the top part of the window, reaching deeper into the room. A daylighting simulation model, validated with full-scale experiments, was developed in order to establish correlations between the shade position, outdoor illuminance and work plane illuminance for different outdoor conditions. Then, a shading control algorithm was developed for application in any location and orientation. The validated model was employed for a sensitivity analysis of the impact of shade optical properties and control on the potential energy savings due to the use of daylighting. The results showed that Daylight Autonomy for the bottom-up shade is 8-58% higher compared to a conventional roller shade, with a difference of 46% further away from the facade, where the use of electric lighting is needed most of the time. The potential reduction in energy consumption for lighting is 21-41%. (author)

  19. Rethinking daylighting and compliance

    Directory of Open Access Journals (Sweden)

    John Mardaljevic

    2013-10-01

    Full Text Available Daylight in buildings is the natural illumination experienced by the occupants of any man-made construction with openings to the outside. Our attempts to formulate some measure of daylight provision in buildings can be traced back over a century, and the daylight factor as we know it today is over 50 years old. Still the most common measure found in guidelines and recommendations worldwide, the daylight factor is used routinely and, it is fair to say, often rather uncritically. The consideration of daylight in buildings has received a new impetus from the accumulation of evidence on the wider benefits of daylight exposure. But it is continuing to prove difficult to advance beyond daylight factors towards a more realistic quantification of daylighting performance that would allow us to accommodate these new considerations in an evaluative schema. This paper examines the basis of current practice with respect to daylight evaluation, and suggests a few ways in which it can be improved with relatively modest additional effort. The paper also critiques some of the recent attempts to advance daylight evaluation by incremental means using so-called “clear sky options”.

  20. Analysis of Daylight Control in a Chateau Interior

    Directory of Open Access Journals (Sweden)

    Jitka Mohelníková

    2018-05-01

    Full Text Available Assessment of daylighting in the residential hall of a historical chateau is presented. The evaluation is based on both the daylight measurement and simulations. Illuminance levels in the interior were controlled in accordance with requirements for light exposition of light sensitive materials. Valuable paintings and claddings as well as wallpapers and furniture upholstery in the hall are extremely light sensitive and they need to be protected from light damage. The daylight measurements and simulations give an overview of daylight conditions in the annual profile for clear sky conditions and for different levels of window shadings.

  1. OPTIMIZATION STUDY OF VISUAL COMFORT AND DAYLIGHT AVAILABILITY AT CADL ITB

    Directory of Open Access Journals (Sweden)

    SIREGAR Mhd. Akbar Anthony

    2016-12-01

    Full Text Available One way to reduce energy consumption in buildings is to use daylighting. However, daylight can cause visual discomfort in the form of glare. Center of Art, Design, and Language (CADL Institut Teknologi Bandung is a building that has windows on west and east facades, so the probability of glare occurrence is high. In this research, CADL was optimized so that the percentage of time that Daylight Glare Probability below 0.21 (%DGP<0.21 is more than 50% and spatial daylight autonomy with illuminance 150 lux and 50% (sDA150lux,50% is more than 30%. In the optimization, vertical blinds, horizontal blinds, and curtains were added. Vertical blinds and horizontal blinds were varied by changing the blade’s opening angle and area covering the windows, while curtains were varied only by changing the area covering the windows. The results show that %DGP<0.21 can be increased beyond 50%, but in some rooms, sDA150,50% also decrease below 30%. The most frequent optimum solutions are vertical blinds 75%-60o.

  2. Development of new types of sun shielding systems based on daylight conducting sun shielding glass slats; Udvikling af nye typer solafskaermningssystemer baseret paa dagslysdirigerende solafskaermende glaslameller

    Energy Technology Data Exchange (ETDEWEB)

    Iversen, A.; Svendsen, Svend (Danmarks Tekniske Univ., DTU Byg, Kgs. Lyngby (Denmark)); Laustsen, J.B. (NIRAS A/S (Denmark)); Traberg-Borup, S.; Johnsen, Kjeld (Statens Byggeforskningsinstitut, Aalborg Univ. (Denmark))

    2009-11-15

    The project has developed a new solar shading system consisting of reflective reflective glass slats, which both must act as general sun shading and also be able to improve daylight conditions inside the building when it's needed, by reflecting light further into the room. Simulations with the program IESve / Radiance are performed of daylight conditions in an office room using the developed solar shading concept. The calculation model is used to optimize the glass slat system's shape and dimensions (slat angle, width and distance). The calculations have shown that a slat angle of 30 degrees gives the best daylight conducting effect in overcast weather. At this position, compared with the same facade without sun shading, a slight reduction of daylight factor close to the windows is obtained while the back of the room is largely unchanged. Compared with traditional slat systems the reflective glass slats provide higher daylight factors in the building. Daylight measurements are performed in a daylight laboratory. Measurements show that the daylight factor in cloudy weather is reduced by approx. 20% 1.2 m from the facade where there are usually plenty of light while it is unchanged or slightly higher at the back of the room where there often are problems with too little daylight. On a clear day with direct sunlight and the reflective slats in shading position the result is a reduction of illumination through the whole room. The developed sun shading system reduces sun irradiance in reflective position without diminishing daylight conditions in the building under overcast conditions when the slats are angled in daylight conducting position. The glass slat system's effect on the thermal indoor environment and energy consumption are analyzed using calculations in the program BSim and by measurements of the sun shading system mounted in the Passys test cell at the Technical University of Denmark. (ln)

  3. Daylight utilisation in office buildings

    DEFF Research Database (Denmark)

    Christoffersen, Jens

    This Ph.D. thesis presents the qualitative and quantitative consequences of full-scale measurements on two daylighting systems, light shelf and Venetian blinds. The systems were investigated to assess their ability to increase daylight penetration and improve daylight distribution in the interior...... the benefits and difficulties regarding use of daylight in office buildings, but it is hoped that the report will provide daylight conscious building design in forthcoming non-domestic buil dings....

  4. Investigating the Influence of Light Shelf Geometry Parameters on Daylight Performance and Visual Comfort, a Case Study of Educational Space in Tehran, Iran

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Moazzeni

    2016-07-01

    Full Text Available Daylight can be considered as one of the most important principles of sustainable architecture. It is unfortunate that this is neglected by designers in Tehran, a city that benefits from a significant amount of daylight and many clear sunny days during the year. Using a daylight controller system increases space natural light quality and decreases building lighting consumption by 60%. It also affects building thermal behavior, because most of them operate as shading. The light shelf is one of the passive systems for controlling daylight, mostly used with shading and installed in the upper half of the windows above eye level. The influence of light shelf parameters, such as its dimensions, shelf rotation angle and orientation on daylight efficiency and visual comfort in educational spaces is investigated in this article. Daylight simulation software and annual analysis based on climate information during space occupation hours were used. The results show that light shelf dimensions, as well as different orientations, especially in southern part, are influential in the distribution of natural light and visual comfort. At the southern orientation, increased light shelf dimensions result in an increase of the area of the work plane with suitable daylight levels by 2%–40% and a significant decrease in disturbing and intolerable glare hours.

  5. Daylight and energy implications for CIE standard skies

    International Nuclear Information System (INIS)

    Li, Danny H.W.

    2007-01-01

    Recently, the International Commission on Illumination (CIE) has adopted a range of 15 standard skies, which include the existing CIE overcast, very clear and cloudless polluted skies, covering the whole probable spectrum of usual skies found in the world. The traditional daylight factor (DF) approach with the calculations being based on an isotropic overcast sky, however, cannot cater to the dynamic variations in daylight luminance and illuminance as the sun's position changes under non-overcast skies. Currently, we propose a numerical procedure that considers the changes in the luminance of sky elements to predict the interior daylight illuminance under the 15 CIE standard skies. This paper evaluates the method by using a typical room with a large vertical glazing window facing north. The available daylight for the room at mean hourly sun positions in each month in terms of DF and illuminance levels were determined and compared with those based on a computer program, namely, RADIANCE. A modification to the ground reflected component was made when a well defined shadow was cast in front of the window facade. It is shown that the results estimated by the proposed approach are in reasonably good agreement with those produced from RADIANCE. The interior daylight and lighting energy consumption were also determined using the proposed and the traditional DF approaches. The findings reveal that daylighting designs using existing CIE overcast sky only would considerably underestimate the indoor daylight availability and electric lighting energy savings, especially under high design indoor illuminance settings

  6. ADASY (Active Daylighting System)

    Science.gov (United States)

    Vázquez-Moliní, Daniel; González-Montes, Mario; Fernández-Balbuena, Antonio Á.; Bernabéu, Eusebio; García-Botella, Ángel; García-Rodríguez, Lucas; Pohl, Wilfried

    2009-08-01

    The main objective of ADASY (Active Daylighting System) work is to design a façade static daylighting system oriented to office applications, mainly. The goal of the project is to save energy by guiding daylight into a building for lighting purpose. With this approach we can reduce the electrical load for artificial lighting, completing it with sustainable energy. The collector of the system is integrated on a vertical façade and its distribution guide is always horizontal inside of the false ceiling. ADASY is designed with a specific patent pending caption system, a modular light-guide and light extractor luminaire system. Special care has been put on the final cost of the system and its building integration purpose. The current ADASY configuration is able to illuminate 40 m2 area with a 300lx-400lx level in the mid time work hours; furthermore it has a good enough spatial uniformity distribution and a controlled glare. The data presented in this study are the result of simulation models and have been confirmed by a physical scaled prototype. ADASY's main advantages over regular illumination systems are: -Low maintenance; it has not mobile pieces and therefore it lasts for a long time and require little attention once installed. - No energy consumption; solar light continue working even if there has been a power outage. - High quality of light: the colour rendering of light is very high - Psychological benefits: People working with daylight get less stress and more comfort, increasing productivity. - Health benefits

  7. Integration Issues for Using Innovative Daylighting Strategies in Light Wells

    Directory of Open Access Journals (Sweden)

    Gashinani M. Gholipour

    2017-12-01

    Full Text Available “Light well” as one of the most common means of daylight tolls in building, experiences severe limitations and deserve special attention. The question is which strategy is the best for increasing the daylight penetration to the depth of buildings. One of the main challenges in deep plan is to guide daylight into the building core and this can be performed through daylighting strategies, but the choice of the proper innovative daylighting system (IDS with several parameters is the problem. This paper aims to find elements for optimal choice and selecting context-compatible tools for light well. The result shows that four macro factors were found at the interaction of building and IDS. Identifying the integration components can play an effective role in decision-making or design a new tolls consistent with the physical conditions of light well and building to overcome the daylight crisis.

  8. A generalized window energy rating system for typical office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Cheng; Chen, Tingyao; Yang, Hongxing; Chung, Tse-ming [Research Center for Building Environmental Engineering, Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong (China)

    2010-07-15

    Detailed computer simulation programs require lengthy inputs, and cannot directly provide an insight to relationship between the window energy performance and the key window design parameters. Hence, several window energy rating systems (WERS) for residential houses and small buildings have been developed in different countries. Many studies showed that utilization of daylight through elaborate design and operation of windows leads to significant energy savings in both cooling and lighting in office buildings. However, the current WERSs do not consider daylighting effect, while most of daylighting analyses do not take into account the influence of convective and infiltration heat gains. Therefore, a generalized WERS for typical office buildings has been presented, which takes all primary influence factors into account. The model includes embodied and operation energy uses and savings by a window to fully reflect interactions among the influence parameters. Reference locations selected for artificial lighting and glare control in the current common simulation practice may cause uncompromised conflicts, which could result in over- or under-estimated energy performance. Widely used computer programs, DOE2 and ADELINE, for hourly daylighting and cooling simulations have their own weaknesses, which may result in unrealistic or inaccurate results. An approach is also presented for taking the advantages of the both programs and avoiding their weaknesses. The model and approach have been applied to a typical office building of Hong Kong as an example to demonstrate how a WERS in a particular location can be established and how well the model can work. The energy effect of window properties, window-to-wall ratio (WWR), building orientation and lighting control strategies have been analyzed, and can be indicated by the localized WERS. An application example also demonstrates that the algebraic WERS derived from simulation results can be easily used for the optimal design of

  9. The New York Times headquarters daylighting mockup: Monitoredperformance of the daylighting control system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eleanor S.; Selkowitz, Stephen E.

    2006-02-24

    A nine-month monitored field study of the performance of automated roller shades and daylighting controls was conducted in a 401 m{sup 2} unoccupied, furnished daylighting mockup. The mockup mimicked the southwest corner of a new 110 km{sub 2} commercial building in New York, New York, where The New York Times will be the major tenant. This paper focuses on evaluating the performance of two daylighting control systems installed in separate areas of an open plan office with 1.2-m high workstation partitions: (1) Area A had 0-10 V dimmable ballasts with an open-loop proportional control system and an automated shade controlled to reduce window glare and increase daylight, and (2) Area B had digital addressable lighting interface (DALI) ballasts with a closed-loop integral reset control system and an automated shade controlled to block direct sun. Daylighting control system performance and lighting energy use were monitored. The daylighting control systems demonstrated very reliable performance after they were commissioned properly. Work plane illuminance levels were maintained above 90% of the maximum fluorescent illuminance level for 99.9{+-}0.5% and 97.9{+-}6.1% of the day on average over the monitored period, respectively, in Areas A and B. Daily lighting energy use savings were significant in both Areas over the equinox-to-equinox period compared to a non-daylit reference case. At 3.35 m from the window, 30% average savings were achieved with a sidelit west-facing condition in Area A while 50-60% were achieved with a bilateral daylit south-facing condition in Area B. At 4.57-9.14 m from the window, 5-10% and 25-40% savings were achieved in Areas A and B, respectively. Average savings for the 7-m deep dimming zone were 20-23% and 52-59% for Areas A and B, respectively, depending on the lighting schedule. The large savings and good reliability can be attributed to the automatic management of the interior shades. The DALI-based system exhibited faulty behavior that

  10. Daylighting on the working plane in oriented attic rooms under overcast and clear sky

    Directory of Open Access Journals (Sweden)

    Kondáš Kristián

    2014-06-01

    Full Text Available The evaluation of daylight conditions in building interiors is based on the Daylight Factor concept after current Slovak standards. Criteria and requirements determined in these standards consider the worst daylight exterior conditions which are described by CIE overcast sky model. The sky luminance distribution of overcast sky is centrical to the zenith, so independence of window orientation to cardinal points is characteristic in daylighting calculations. The sky luminance distribution modelling is one of the main task of the daylight source research more than 50 years. It is evident that also other types of sky conditions exist in nature. An introduction of a new criterion based on photometric variables, which also consider sunlight influence, is expected. This article represents a study of the influence of the interior orientation on distribution of daylighting in attic spaces under an overcast and clear sky

  11. Lighting control and dimensioning in integrated daylight systems

    Energy Technology Data Exchange (ETDEWEB)

    Halonen, L.; Eloholma, M.; Lehtovaara, J.

    1996-12-31

    The objective of this research was to find out the subjective and individual requirements for lighting control in connection with daylight utilization in indoor lighting. There is a great potential to use daylight in indoor lighting. This sets demands for the integrated daylight control systems, so that the indoor lighting can be optimized and demands of the users can be fulfilled. Control strategies should also take into account individual light needs, luminance balance and visual comfort. New lighting control systems and strategies such as vertical/horizontal illuminance ratio were studied. The incoming daylight may radically change the luminance distribution of the visual field and the effects of daylight on luminances of vertical surfaces may become especially noticeable. When daylight is utilized in indoor lighting, special care has to be taken to maintain the quality of the lighting of the visual environment. The windows become a potential source of discomfort glare in offices in uncontrolled daylight conditions. With the present methods it is not possible to evaluate discomfort glare caused by high surface luminances or windows. The results of this research do not support the opinion that low vision people in offices need more light than the normally sighted or that the illumination levels should be raised for low vision people. The rise of lighting levels from the present practice (task illuminance level 500 lux) in office work does not improve the visual performance of low vision people. In planning the visual environment for the low vision people care has to be taken on the direction of light. (7 refs.)

  12. Design and evaluation of daylighting applications of holographic glazings

    Energy Technology Data Exchange (ETDEWEB)

    Papamichael, K.; Ehrlich, C.; Ward, G.

    1996-12-01

    According to the contractual agreement, BTP would develop a computer model of the POC holographic structures and then simulate the performance of alternative designs using the RADIANCE lighting and rendering computer program [Ward 1990]. The RADIANCE model would then be used to evaluate the daylight performance of alternative designs of holographic glazings in a prototypical office space. The simulation process would be validated against actual photometric measurements of holographic glazing samples developed by POC. The results would be used to evaluate the potential for increased electric lighting savings through increased daylight illuminance levels at distances more than 15 ft--20 ft (4.6 m--6.1 m ) from the window wall.

  13. Experiences collected with a daylight system

    International Nuclear Information System (INIS)

    Krueger, P.

    1981-01-01

    The Kodak Daylight System is space-saving. It consists of the Kodak-X-Omat cassette, the identification camera and the loading and reloading device (cassette multiloader). All three units of this system are notable for extremely safe operation. Handling is simple and easily appreciated. All brands of film can be used. The data window in the cassette is too large; in some cases, important sections of the image can be covered up by the window. Automatic loading and reloading considerably reduces solling of the cassette, which is otherwise common, and also reduces abrasion of the intensifying screen. Introduction of this system has had a beneficial effect on overall working and has been welcomed by all concerned as a contribution towards facilitating routine work. (orig.) [de

  14. Analysis and prediction of daylighting and energy performance in atrium spaces using daylight-linked lighting controls

    International Nuclear Information System (INIS)

    Chow, Stanley K.H.; Li, Danny H.W.; Lee, Eric W.M.; Lam, Joseph C.

    2013-01-01

    Highlights: ► Daylight-linked lighting control and energy performance for atrium is studied. ► Field measurement of automatic dimming control shows 93% energy saving. ► Field measurement of manual on–off control shows 95% energy saving. ► Atrium illuminance is correlated with daylight factor for energy saving prediction. - Abstract: In subtropical Hong Kong, a certain amount of electricity is used to create visually comfortable interior spaces through electric lighting, which is the second major electricity-consuming item in commercial buildings, accounting for 20–30% of total electricity use. The burning of fossil fuels for electricity generation has many adverse effects on the environment. Daylighting is an important and useful strategy for enhancing visual comfort and reducing the need for the electricity consumed by light fittings. The rational use of daylight through tools such as photoelectric lighting controls can effectively reduce buildings’ electricity consumption and the related pollutants and greenhouse gas emissions. Daylighting design techniques are often best demonstrated via field measurements that provide reliable operational and energy performance data for establishing design guidelines. An atrium provides an environmentally controlled indoor public space that introduces daylight into the hearts of large buildings. In circulation areas such as corridors, people expect the way ahead to be sufficiently lit and daylight-linked lighting controls can deliver excellent energy savings. This paper presents the daylighting and energy performance of an atrium space using daylight-linked lighting controls. The cost, energy and environmental issues related to various daylight illuminances are estimated and design implications are discussed

  15. Advanced energy efficient windows

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund

    2007-01-01

    Windows should be paid special attention as they contribute a significant part of the total heat-loss coefficient of the building. Contrary to other parts of the thermal envelope the windows are not only heat loosers, but may gain heat in the day-time. Therefore there are possibilities for large...... energy savings. In terms of energy, windows occupy a special position compared with other thermal envelope structures due to their many functions: 1) windows let daylight into the building and provide occupants with visual contact with their surroundings 2) windows protect against the outdoor climate 3......) windows transmit solar energy that may contribute to a reduction of energy consumption, but which may also lead to unpleasant overheating. In the following paragraphs the current use of windows is reviewed with an emphasis on energy, while special products like solar protection glazing and security...

  16. Evaluation of Daylight Intensity for Sustainbility in Residential Buildings in Cantonment Cottages Multan

    Directory of Open Access Journals (Sweden)

    SUMRA YOUSUF

    2017-07-01

    Full Text Available Day lighting is a useful and effective source of energy savings and visual comforts in buildings. Occupants expect good daylight in their living spaces for better living environment. The quality and quantity of natural light entering in to a building depend on both internal and external factors. Daylight strategies basically depend on the accessibility of natural light that is determined by the latitude of the building site and the conditions surrounding the building. Daylight provides lighting energy and energy demand reduction during peak utility hours. Bringing daylight into a building that displaces electric lighting and provides sufficient illumination is the greenest way to light a building presently. This research, aims at analyzing the daylight intensity in residential buildings in Cantonment Cottages Multan which is one of the hottest and progresse city of Pakistan. The intensity of daylight can be expressed in the terms of luminance and daylight factor. In this research, the 5 and 7 marla houses in Cantt Cottages in Multan were selected. The device lux meter was used for measuring intensity with which the brightness appears to the human eye. The readings were taken by placing Lux Meter at the center and near windows in each building component at 2-4 pm. Inorderto evaluate the daylight intensity, the measured luminance in each component of building is compared with the standard illuminance as per recommendation of CIBSE (Chartered Institute of Building Service Engineers. After investigation, it has been found that daylight factor is much higher than the standard values

  17. Lives under the Sun; The sensory qualities of daylight in designing the everyday

    DEFF Research Database (Denmark)

    Hauge, Bettina

    2015-01-01

    People’s sensations of daylight and their practical, daily engagements with the sun and the daylight are described in this article. Based on a qualitative research project in Denmark the article shows how some Danes experience the world through the sun and its daylight and illustrates its...... significance to their bodies and lives as they describe it. By taking a biomimetic approach a metaphor is presented that, like plants, some people crave daylight in order to feel well. By showing people’s engagement with the sun and its daylight the phenomenon of natural light becomes imbued with sociality...... and it is described how people design their everyday in accordance with the sun. The sensation of daylight normally taken for granted and acknowledged as a physiological element in our being-in-the-world is foregrounded and shown as a sense in people that may have a physiological origin when daylight hits the eye...

  18. The daylighting dashboard - A simulation-based design analysis for daylit spaces

    Energy Technology Data Exchange (ETDEWEB)

    Reinhart, Christoph F. [Harvard University, Graduate School of Design, 48 Quincy Street, Cambridge, MA 02138 (United States); Wienold, Jan [Fraunhofer Institute for Solar Energy Systems, Heidenhofstrasse 2, 79110 Freiburg (Germany)

    2011-02-15

    This paper presents a vision of how state-of-the-art computer-based analysis techniques can be effectively used during the design of daylit spaces. Following a review of recent advances in dynamic daylight computation capabilities, climate-based daylighting metrics, occupant behavior and glare analysis, a fully integrated design analysis method is introduced that simultaneously considers annual daylight availability, visual comfort and energy use: Annual daylight glare probability profiles are combined with an occupant behavior model in order to determine annual shading profiles and visual comfort conditions throughout a space. The shading profiles are then used to calculate daylight autonomy plots, energy loads, operational energy costs and green house gas emissions. The paper then shows how simulation results for a sidelit space can be visually presented to simulation non-experts using the concept of a daylighting dashboard. The paper ends with a discussion of how the daylighting dashboard could be practically implemented using technologies that are available today. (author)

  19. Investigation of Architectural Strategies in Relation to Daylight and Integrated Design

    DEFF Research Database (Denmark)

    Jørgensen, Michael; Iversen, Anne; Bjerregaard Jensen, Lotte

    2012-01-01

    his paper investigates the use of daylight in three architecturally successful buildings. The aim is to discuss the challenges and opportunities of architectural daylight strategies in relation to integrated design. All these buildings were designed with the focus on a strategy of using daylight...... to create well-lit, exciting spaces and spatial sequences. The original ideas, thoughts, and decisions behind the designs and daylight strategy are compared with answers in questionnaires from test subjects who have experienced the space and lighting conditions created. The results indicate...... that the architectural daylight strategies formulated by the architects and engineers at the beginning of the design process are actually experienced by the “users” in the existing buildings. The architectural daylight strategy was different in each of the three libraries, and analysis of the results shows that daylight...

  20. DAYLIGHTING PERFORMANCE OF HORIZONTAL LIGHT PIPE BRANCHING ON OPEN PLAN OFFICE SPACE

    Directory of Open Access Journals (Sweden)

    Feny ELSIANA

    2015-12-01

    Full Text Available For daylighting purpose, office buildings should have a shallow plan and increase the ratio of surface to building’s volume. However, intensive use of air-conditioning drives office building’s plan to be deep with a minimum surface to volume ratio. This leads to the presence of areas that have insufficient daylight level at the work plane. Considering limitations of some daylighting methods in distributing daylight to these areas, Horizontal Light Pipe (HLP was selected. The aim of this research was to evaluate and explain the effect of HLP branching on daylight quantity and distribution inside open plan office space. Experimental with simulation as a tool was used as the research method. HLP branching’s uniformity ratio, illuminance and Daylight Factor were compared with unbranching HLP, simultaneously with daylighting standards. Results showed that office space with HLP-L branching had higher daylight level than HLP-T branching, 296 lux and 295 lux, HLP-L and HLP-T, respectively. However, HLP-T branching distributed daylight more evenly than HLP-L branching, with uniformity ratio as 1.49:1 and 1.50:1, HLP-T and HLP-L, respectively. Both of them met the illuminance target value and uniformity at work plane. Light’s deflection and improvement amount of opening distribution decreased average illuminance and Daylight Factor up to 3.59%. Those also decreased uniformity of daylight inside the space.

  1. Fuzzy-Neural Automatic Daylight Control System

    Directory of Open Access Journals (Sweden)

    Grif H. Şt.

    2011-12-01

    Full Text Available The paper presents the design and the tuning of a CMAC controller (Cerebellar Model Articulation Controller implemented in an automatic daylight control application. After the tuning process of the controller, the authors studied the behavior of the automatic lighting control system (ALCS in the presence of luminance disturbances. The luminance disturbances were produced by the authors in night conditions and day conditions as well. During the night conditions, the luminance disturbances were produced by turning on and off a halogen desk lamp. During the day conditions the luminance disturbances were produced in two ways: by daylight contributions changes achieved by covering and uncovering a part of the office window and by turning on and off a halogen desk lamp. During the day conditions the luminance disturbances, produced by turning on and off the halogen lamp, have a smaller amplitude than those produced during the night conditions. The luminance disturbance during the night conditions was a helpful tool to select the proper values of the learning rate for CMAC controller. The luminance disturbances during the day conditions were a helpful tool to demonstrate the right setting of the CMAC controller.

  2. Impact of shading on daylight quality. Simulations with radiance

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, M.C.

    2001-07-01

    The impact of six exterior shading devices on daylight quality and on the potential for daylight utilisation in a standard, south-oriented office room was investigated through computer simulations with Radiance. The daylight quality was evaluated by considering four performance indicators: the absolute work plane illuminance, the illuminance uniformity on the work plane, the absolute luminance in the visual field and the luminance ratios between the work plane, VDT screen and surrounding surfaces. The results indicate that the overhang, white awning and horizontal venetian blind generated work plane illuminance levels that are more suitable for offices where traditional tasks are carried out. However, these devices did not prevent high luminance values at the window. On the other hand, the grey specular screen produced unacceptably low work plane illuminance, poor illuminance uniformity and unacceptably low luminance levels which resulted in unsuitable luminance ratios between the VDT screen, work plane and surroundings. The 45 deg venetian blind, white screen and blue awning provided work plane illuminance levels suitable for offices where a combination of paper and computer work is carried out. They also provided acceptable illuminance uniformity on the work plane, suitable luminance ratios between the work plane, VDT screen and surroundings and they significantly reduced the luminance of the window. However, the blue awning had a poorer performance in December than in June and the white screen resulted in high luminance values at the window, which indicates that the best device among the ones studied was the 45 deg venetian blind.

  3. Optimal sun-shading design for enhanced daylight illumination of subtropical classrooms

    Energy Technology Data Exchange (ETDEWEB)

    Ho, Ming-Chin [Architecture and Building Research Institute, MOI (China); Chiang, Che-Ming [Department of Architecture, National Cheng-Kung University, Tainan 701 (China); Chou, Po-Cheng [Department of Interior Design, Shu-Te University, No. 59 Hun-Shan Road, Yenchau 82445, Kaohsiung County (China); Chang, Kuei-Feng [Department of Real Estate Management, National Pingtung Institute of Commerce (China); Lee, Chia-Yen [Department of Mechanical and Automation Engineering, Da-Yeh University, Changhua 515 (China)

    2008-07-01

    This study investigates the feasibility of fitting windows with sun-shadings in order to minimize the lighting power costs in daylight-illuminated classrooms lit from a single side in subtropical regions. An IES-CPC model is created of a representative classroom in Taiwan, and a series of simulations is performed to determine the average illuminance value and the uniformity of the illuminance distribution in the classroom under various lighting conditions with no sun-shadings fitted to the window. The numerical results are found to be in good agreement with the experimental measurements obtained using an array of nine-channel photometers. Having confirmed the validity of the simulation scheme, the illumination properties of four different sun-shading designs are considered. The results show that a double-layered sun-shading represents the optimal sun-shading design in terms of achieving a uniform illumination distribution within the classroom. Given appropriate physical dimensions, this daylight access device achieves the minimum illuminance requirement of 500 lx and improves the lighting uniformity ratio from 0.25-0.35 to 0.40-0.42. Furthermore, using this sun-shading device, the required illuminance ratio of 0.5 can be obtained simply by switching on one of the three rows of lights in the classroom. Accordingly, the daylight access device not only improves the illuminance conditions within the classroom, but also reduces the lighting power cost by 71.5% compared to the case where all of the lights are turned on. (author)

  4. Impact of solar shading on daylight quality. Measurements in experimental office rooms

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, M.C.

    2001-07-01

    The impact of ten solar shading screens and one venetian blind on daylight quality was studied through measurements in two south-oriented experimental office rooms. The daylight quality was assessed by considering five performance indicators: the daylight factor, the work plane illuminance, the illuminance uniformity on the work plane, the absolute luminance in the field of view and the luminance ratios between the paper task, the walls and the VDT screen. The measurements were carried out under perfect sunny conditions and overcast conditions. The results show that the shading devices can be divided into three distinct groups. Group 1 consists of all dark-coloured screens; Group 2 includes the closed venetian blind while Group 3 includes the white screens and the horizontal venetian blind. The devices of Group 1 produced unacceptably low work plane illuminance and vertical luminance values which resulted in unsuitable luminance ratios between the task, the walls and VDT screen. However, these devices reduced the luminance of the window (sky) to acceptable levels. The devices of Group 3 did not prevent high window luminance but yielded higher levels of work plane illuminance and inner wall luminance, which makes them suitable for traditional paper tasks. They also generated high wall luminance values which resulted in a number of unacceptable luminance ratios between the task, walls and VDT screen. The closed venetian blind (Group 2) was the only device which scored well on all performance indicators considered. It provided ideal illuminance levels for paper and VDT tasks and resulted in favourable wall luminance values for computer work.

  5. Optical Characterization and Energy Simulation of Glazing for High-Performance Windows

    International Nuclear Information System (INIS)

    Jonsson, Andreas

    2010-01-01

    This thesis focuses on one important component of the energy system - the window. Windows are installed in buildings mainly to create visual contact with the surroundings and to let in daylight, and should also be heat and sound insulating. This thesis covers four important aspects of windows: antireflection and switchable coatings, energy simulations and optical measurements. Energy simulations have been used to compare different windows and also to estimate the performance of smart or switchable windows, whose transmittance can be regulated. The results from this thesis show the potential of the emerging technology of smart windows, not only from a daylight and an energy perspective, but also for comfort and well-being. The importance of a well functioning control system for such windows, is pointed out. To fulfill all requirements of modern windows, they often have two or more panes. Each glass surface leads to reflection of light and therefore less daylight is transmitted. It is therefore of interest to find ways to increase the transmittance. In this thesis antireflection coatings, similar to those found on eye-glasses and LCD screens, have been investigated. For large area applications such as windows, it is necessary to use techniques which can easily be adapted to large scale manufacturing at low cost. Such a technique is dip-coating in a sol-gel of porous silica. Antireflection coatings have been deposited on glass and plastic materials to study both visual and energy performance and it has been shown that antireflection coatings increase the transmittance of windows without negatively affecting the thermal insulation and the energy efficiency. Optical measurements are important for quantifying product properties for comparisons and evaluations. It is important that new measurement routines are simple and applicable to standard commercial instruments. Different systematic error sources for optical measurements of patterned light diffusing samples using

  6. Evaluation of daylight intensity for sustainbility in residential buildings in cantonment cottages multan

    International Nuclear Information System (INIS)

    Yousuf, S.; Maqsood, S.

    2017-01-01

    Day lighting is a useful and effective source of energy savings and visual comforts in buildings. Occupants expect good daylight in their living spaces for better living environment. The quality and quantity of natural light entering in to a building depend on both internal and external factors. Daylight strategies basically depend on the accessibility of natural light that is determined by the latitude of the building site and the conditions surrounding the building. Daylight provides lighting energy and energy demand reduction during peak utility hours. Bringing daylight into a building that displaces electric lighting and provides sufficient illumination is the greenest way to light a building presently. This research, aims at analyzing the daylight intensity in residential buildings in Cantonment Cottages Multan which is one of the hottest and progresse city of Pakistan. The intensity of daylight can be expressed in the terms of luminance and daylight factor. In this research, the 5 and 7 marla houses in Cantt Cottages in Multan were selected. The device lux meter was used for measuring intensity with which the brightness appears to the human eye. The readings were taken by placing Lux Meter at the center and near windows in each building component at 2-4 pm. In order to evaluate the daylight intensity, the measured luminance in each component of building is compared with the standard illuminance as per recommendation of CIBSE (Chartered Institute of Building Service Engineers). After investigation, it has been found that daylight factor is much higher than the standard values as per recommended by CIBSE. The design parameters including building orientation, glazing area, room size to window opening ratio etc. is not appropriate with respect to sustainable design. (author)

  7. Colour Mixing Based on Daylight

    Science.gov (United States)

    Meyn, Jan-Peter

    2008-01-01

    Colour science is based on the sensation of monochromatic light. In contrast to that, surface colours are caused by reflection of wide sections of the daylight spectrum. Non-spectral colours like magenta and purple appear homologous to colours with spectral hue, if the approach of mixing monochromatic light is abandoned. It is shown that a large…

  8. Lightpipe applications for daylighting systems

    NARCIS (Netherlands)

    Rosemann, A.; Kaase, H.

    One of the main research activities of the Institute of Lighting at Technical University of Berlin concerns efficient daylight utilisation in buildings. In recent years, several national and international projects have been and are still carried out. One of them, the European research project

  9. Daylight as a building material

    DEFF Research Database (Denmark)

    Thule Kristensen, Peter; Madsen, Merete

    2005-01-01

    The article draws on examples to chronologically trace the use of daylight as building material in architecture of the 20th and early 21st century. The essay covers works of Mies van der Rohe, Le Corbusier, Erik Bryggman, Rudolf Schwarz, Alvar Aalto, Aldo Rossi, Jørn Utzon, Daniel Libeskind, Peter...

  10. Quantifying the potential of automated dynamic solar shading in office buildings through integrated simulations of energy and daylight

    DEFF Research Database (Denmark)

    Nielsen, Martin Vraa; Svendsen, Svend; Bjerregaard Jensen, Lotte

    2011-01-01

    The façade design is and should be considered a central issue in the design of energy-efficient buildings. That is why dynamic façade components are increasingly used to adapt to both internal and external impacts, and to cope with a reduction in energy consumption and an increase in occupant...... them with various window heights and orientations. Their performance was evaluated on the basis of the building’s total energy demand, its energy demand for heating, cooling and lighting, and also its daylight factors. Simulation results comparing the three façade alternatives show potential...

  11. Hybrid daylight/light-emitting diode illumination system for indoor lighting.

    Science.gov (United States)

    Ge, Aiming; Qiu, Peng; Cai, Jinlin; Wang, Wei; Wang, Junwei

    2014-03-20

    A hybrid illumination method using both daylight and light-emitting diodes (LEDs) for indoor lighting is presented in this study. The daylight can be introduced into the indoor space by a panel-integration system. The daylight part and LEDs are combined within a specific luminaire that can provide uniform illumination. The LEDs can be turned on and dimmed through closed-loop control when the daylight illuminance is inadequate. We simulated the illumination and calculated the indoor lighting efficiency of our hybrid daylight and LED lighting system, and compared this with that of LED and fluorescent lighting systems. Simulation results show that the efficiency of the hybrid daylight/LED illumination method is better than that of LED and traditional lighting systems, under the same lighting conditions and lighting time; the method has hybrid lighting average energy savings of T5 66.28%, and that of the LEDs is 41.62%.

  12. Application of automated blind for daylighting in tropical region

    International Nuclear Information System (INIS)

    Chaiwiwatworakul, Pipat; Chirarattananon, Surapong; Rakkwamsuk, Pattana

    2009-01-01

    This paper reports an experimental and simulation study on application of automated Venetian blind for daylighting in tropical climate. A horizontal blind system operating automatically under programmed control was constructed and integrated onto the glazed windows to form a window system with an automated blind in a room of a laboratory building. A dimming controller was also integrated to the lighting system of the room. Different operation schemes of the window system were devised and tested in the attempt to maximize energy savings while maintaining the quality of the visual environment in the room. Intensive measurement of illuminance of the interior space was undertaken during the experiments. A methodology for calculation of interior daylight illuminance and associated glare corresponding to the configurations of the experiments was adopted. The method was coded into a computer program. Results of calculation from the program agree well with those from experiments for all the schemes of operation conducted. The program was used to simulate the situation when each scheme of operation was implemented for a whole year. It was found that such window system with automated blind enabled energy savings of 80%, but a more sophisticated scheme also helped maintain the interior visual quality at high level.

  13. Daylight photodynamic therapy for actinic keratosis

    DEFF Research Database (Denmark)

    Wiegell, Stine; Wulf, H C; Szeimies, R-M

    2011-01-01

    clinic visits and discomfort during therapy. In this article, we critically review daylight-mediated PDT, which is a simpler and more tolerable treatment procedure for PDT. We review the effective light dose, efficacy and safety, the need for prior application of sunscreen, and potential clinical scope...... of daylight-PDT. Three randomized controlled studies have shown that daylight-mediated PDT is an effective treatment of thin AKs. Daylight-mediated PDT is nearly pain-free and more convenient for both the clinics and patients. Daylight-mediated PDT is especially suited for patients with large field......-cancerized areas, which can easily be exposed to daylight. Further investigations are necessary to determine at which time of the year and in which weather conditions daylight-mediated PDT will be possible in different geographical locations....

  14. Impact of Furniture Layout on Indoor Daylighting Performance in Existing Residential Buildings in Malaysia

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Mousavi

    2018-06-01

    Full Text Available Currently, home-based computing workspaces have developed substantially all over the world, especially in Malaysia. This growing trend attracts computer workers to run a business from their residential units. Hence, visual comfort needs to be considered in addition to thermal comfort for home workers in their residential working rooms. While such rooms are always occupied with furniture, the layout of the furniture may influence the indoor daylighting distribution. Several various furniture layouts can be arranged in a residential working room. However, to have better generalisation, this study focused on the impacts of mostly-used-furniture-layouts (MUFLs on indoor daylighting performance in residential working rooms. The field measurement was conducted in a typically furnished room under a tropical sky to validate the results of the simulation software under different sky conditions. Then, daylight ratio (DR, as a quantitative daylighting variable, and the illuminance uniformity ratio (IUR, CIE glare index (CGI, and Guth visual comfort probability (GVCP, as qualitative daylighting variables, were analysed through simulation experiments. In conclusion, by changing the furniture layout, daylight uniformity recorded the highest fluctuations in the case room among all variables. While various furniture layouts, in a residential working room in the tropics, may even slightly reduce the extreme indoor daylight quantity, they can worsen the indoor daylight quality compared to an unfurnished space. The paper shows that furniture as an interior design parameter cannot help to improve tropical daylighting performance in a building.

  15. Colour mixing based on daylight

    International Nuclear Information System (INIS)

    Meyn, Jan-Peter

    2008-01-01

    Colour science is based on the sensation of monochromatic light. In contrast to that, surface colours are caused by reflection of wide sections of the daylight spectrum. Non-spectral colours like magenta and purple appear homologous to colours with spectral hue, if the approach of mixing monochromatic light is abandoned. It is shown that a large region of the colour space can be covered by mixing three primary colours derived from lossless spectral decomposition of daylight. These primaries are specified by hue, saturation and luminosity. Duality of additive and subtractive mixing is formulated quantitatively. Experimental demonstrations of calculated results are suggested. This paper is intended for undergraduate optics courses, and advanced interdisciplinary seminars on arts and physics

  16. Discomfort glare with complex fenestration systems and the impact on energy use when using daylighting control

    Energy Technology Data Exchange (ETDEWEB)

    Hoffmann, Sabine; McNeil, Andrew; Lee, Eleanor S.; Kalyanam, Raghuram

    2015-11-03

    Glare is a frequent issue in highly glazed buildings. A modelling approach is presented that uses discomfort glare probability and discomfort glare index as metrics to determine occupants’ behaviour. A glare control algorithm that actuated an interior shade for glare protection based on the predicted perception was implemented in a building simulation program. A reference case with a state-of-the-art base glazing was compared to the same glazing but with five different complex fenestration systems, i.e., exterior shades. The windows with exterior shades showed significant variations in glare frequencies. Energy use intensity in a prototypical office building with daylighting controls was greatly influenced for the systems with frequent glare occurrence. While the base glazing could benefit from glare control, some of the exterior shades showed significantly greater energy use when discomfort glare-based operation of interior shades was considered.

  17. Energy savings due to daylight and artificial lighting integration in office buildings in hot climate

    Energy Technology Data Exchange (ETDEWEB)

    Al-Ashwal, Nagib T. [Sana' a University, Sana' a (Yemen); Budaiwi, Ismail M. [King Fahd University of Petroleum and Minerals, Dhahran (Saudi Arabia)

    2011-07-01

    Reducing energy consumption while maintaining acceptable environmental quality in buildings has been a challenging task for building professionals. In office buildings, artificial lighting systems are a major consumer of energy and can significantly contribute to building cooling load. Furthermore, although reliable, artificial lighting does not necessarily provide the required quality of lighting. Significant improvement in lighting quality and energy consumption can be achieved by proper integration of daylight and artificial lighting. The objective of this study is to investigate the energy performance of office buildings resulting from daylight and artificial lighting integration in hot climates. A parametric analysis is conducted to find the impact of different window design parameters, including window area, height and glazing type, on building energy performance. Results have shown that as much as 35% reduction in lighting energy consumption and 13% reduction in total energy consumption can be obtained when proper daylighting and artificial lighting integration is achieved.

  18. Daylighting, Space, and Architecture: A Literature Review

    Directory of Open Access Journals (Sweden)

    Dalia Hafiz

    2015-12-01

    Full Text Available Daylighting dynamism and constant change can characterize buildings and spaces with a living quality that cannot be achieved with any other design element. However, daylighting can create unwanted lighting conditions in the visual field causing discomfort and glare. This may affect the performance of building occupants such as workers or students. Consequently, designing for daylighting needs a good understanding of daylighting. Designers can rely on information from simulation software to re-imagine the space, especially to examine possible unexpected visual discomfort conditions.This paper aims to represent different visual comfort evaluation methods that can help decision-makers make better informed decisions. Different definitions and structures associated with daylight and glare are examined. It also presents a review of the literature of previous research conducted on daylighting, visual comfort analysis and glare studies.

  19. Architecture, energy and daylight. Study of seven buildings; Arkitektur, energi og dagslys. Undersoegelse af syv bygninger

    Energy Technology Data Exchange (ETDEWEB)

    Christoffersen, J.; Petersen, E.; Svensson, O.

    2001-07-01

    The purpose of this research project was to enhance the designer's knowledge for designing buildings, rooms and window openings which utilise daylight in such a way that aesthetic and functional requirements can be met and energy consumption for electric lighting can be reduced at the same time. It was not the purpose of the project to develop guidelines but only to demonstrate how good daylight conditions and energy conservation can be achieved. The daylight conditions in the seven selected buildings were registered and assessed by the panel on two field trips in the spring of 1999. During these visits, the research team registered the location of rooms, their orientation, windows, artificial lighting etc. After the field trips, the buildings were photographed and the research group performed measurements and analyses of the lighting conditions in the rooms. However, the quality of daylight cannot be determined based only on measurements. The four professionals therefore supplemented the measurements with a subjective evaluation. The study of these seven buildings led to a number of results that must be assumed to be generally valid. A main result is that good daylight conditions in no way prevents or impedes the creation of good architecture. On the contrary, quality of daylight creates both functional as well as aesthetically satisfactory architecture. In all the investigated buildings, the ratio of glass areas to floor area is highter than 10%. In Denmark, this ratio would ensure reasonable daylight access and a view out. However, when size of glass area and daylight measurements are compared, the relationship between them is not straight-forward. The quantity and quality of daylight in buildings depend on other factors too, such as the depth of window openings, solar shading devices, opposite buildings, outdoor vegetation etc. The study points out that there are no standard solutions of how to design facades and window openings which satisfy all

  20. Simple tool to evaluate the impact of daylight on building energy consumption

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Nielsen, Toke Rammer; Svendsen, Svend

    2008-01-01

    This paper presents a simple building simulation tool for integrated daylight and thermal analysis. The tool is capable of importing the thermal and visual properties for different glazings and shading positions from the Window Information System (WIS) program. A coupled ray-tracing and radiosity...

  1. Simple tool to evaluate the impact of daylight on building energy consumption

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Nielsen, Toke Rammer; Svendsen, Svend

    2008-01-01

    This paper presents a simple building simulation tool for integrated daylight and thermal analysis. The tool is capable of importing the thermal and visual properties for different glazings and shading positions from the Window Information System (WIS) program. Radiosity methodology is used...

  2. Daylight metrics and energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Mardaljevic, John; Heschong, Lisa; Lee, Eleanor

    2009-12-31

    The drive towards sustainable, low-energy buildings has increased the need for simple, yet accurate methods to evaluate whether a daylit building meets minimum standards for energy and human comfort performance. Current metrics do not account for the temporal and spatial aspects of daylight, nor of occupants comfort or interventions. This paper reviews the historical basis of current compliance methods for achieving daylit buildings, proposes a technical basis for development of better metrics, and provides two case study examples to stimulate dialogue on how metrics can be applied in a practical, real-world context.

  3. Performance of Anidolic Daylighting Systems in tropical climates - Parametric studies for identification of main influencing factors

    Energy Technology Data Exchange (ETDEWEB)

    Linhart, Friedrich; Scartezzini, Jean-Louis [Solar Energy and Building Physics Laboratory (LESO-PB), Swiss Federal Institute of Technology in Lausanne (EPFL), 1015 Lausanne (Switzerland); Wittkopf, Stephen K. [School of Design and Environment, Department of Architecture, National University of Singapore, 4 Architecture Drive, Singapore 117566 (Singapore)

    2010-07-15

    Making daylight more available in buildings is highly desirable, not only for reasons of energy-efficiency, but also for improvement of occupants' health and well-being. Core-daylighting, that is daylight provision in areas situated at considerable distances from facades and windows, is currently one of the main challenges in sustainable building design. Anidolic Daylighting Systems (ADSs) are one very promising technology in the field of core-daylighting, but commercial solutions that are not only well-performing but also financially competitive are not yet widely available. This article presents results of parametric studies on Anidolic Integrated Ceilings (AICs), a special type of ADS, for identification of main influencing factors. The article describes a reliable method for simulating ADS and AIC performance under given sky conditions. Various simulation results for the example location Singapore are discussed in detail, it is concluded that the main influencing factors are coating material, system dimensions and external obstruction, and those influencing factors' potential impacts are quantified. It is shown that AIC overall efficiencies can reach up to almost 50% in Singapore. The essentially new results presented in this article can be of great help to architects, engineers and scientists in the future, when it comes to precisely dimensioning ADS for various buildings and daylight conditions. (author)

  4. Daylighting practices of the architectural industry (baseline results of a national survey)

    Energy Technology Data Exchange (ETDEWEB)

    Hattrup, M.P.

    1990-05-01

    A national survey of over 300 commercial design architects was conducted to develop baseline information on their knowledge, perceptions, and use of daylighting in commercial building designs. Pacific Northwest Laboratory conducted the survey for the US Department of Energy's (DOE) Office of Building and Community Systems (BCS). In the survey daylighting was defined as the intentional use of natural light as a partial substitute for artificially generated light. The results suggested that architects need to be educated about the true benefits of daylighting and the impacts it can have on a building's energy performance. Educational programs that will increase the architects' understanding and awareness of modern daylighting technologies and practices should be developed by utilities, stage agencies, and the federal government. If more architects can be made aware of the true effectiveness and positive attributes of daylighting systems and technologies, daylighting may be used in more commercial buildings. The results of the survey show that the more familiar architects feel they are with daylighting, the more they use daylighting. 3 refs., 19 tabs.

  5. Daylighting as the Driving Force of the Design Process: from the Results of a Survey to the Implementation into an Advanced Daylighting Project

    Directory of Open Access Journals (Sweden)

    Valerio R.M. Lo Verso

    2014-12-01

    Full Text Available This paper presents a study for the transformation of an industrial area in Turin, Italy. The area hosts two buildings (one of which appointed as listed to be transformed into dwellings. A synergic approach was adopted which combined expertise from architecture, social-economics, psychology and building physics sciences. Building physics sciences lead the research team. A user-centered design was pursued, using a bottom-up approach. A specifically developed questionnaire was submitted on-line to potential users. The survey showed that ‘amount of daylight’, ‘size of rooms’, ‘tranquility of the area’ and ‘presence of a private garden’ were perceived by users to be the most positive aspects of both their present and future, ideal home. These results were then implemented into the project. The exploitation of daylight became the driving force of the transformation project. Especially for the listed building, skylights and light wells were designed to bring daylight into the cores of the buildings, which host common spaces such as libraries or study rooms. The amount of daylight was assessed through the legislative index of the average daylight factor and through a climate-based modeling approach, calculating dynamic metrics such as the spatial daylight autonomy and the Useful Daylight Illuminance. The paper critically compares and discusses these two approaches. Finally, the energy demand for lighting was also calculated to analyze how the increased exploitation of daylight may imply a reduced need for electricity for lighting.

  6. Application and Computer Analysis of Solar Systems for the Indoor Daylighting

    International Nuclear Information System (INIS)

    Makhmudov, Is Kandar

    2010-02-01

    A steady increase of energy costs and ever growing environmental concerns in recent years have forced scientists to look for new methods of energy utilization. To resolve these dire problems, the application of renewable energy sources has been considered in various human activities in every sector of society. One of them is the development of solar daylighting systems for residential and commercial buildings, which can improve building energy efficiency and create comfortable indoor environment. Electric lighting represents up to 30 % of building electricity consumption. Therefore, using sunlight in indoor daylighting can significantly reduce electricity consumption in residential and commercial buildings. Moreover, daylight is an important factor in visual environment and improving human well-being. In last decades, different approaches to the design of solar daylighting systems have resulted in various innovative solutions to efficiently introduce natural light in buildings. But their efficiency and cost are still one of primary obstacles in the wider development and distribution of solar daylighting systems. In this study, we investigated the performance of a new solar concentrator system for indoor illumination. The solar concentrator system consists of 30 cm dish concentrators, high precision solar trackers, optical fibers and diffusers for a light distribution. In order to assess the daylighting system's efficiency, there were carried out several experimental measurement series. One of them was an application of our solar daylighting system to two standard classrooms with south- and north-oriented windows in Jeju city, Korea. At the same time classrooms were modeled by using ECOTECT and exported to RADIANCE for daylighting simulations. Results from the measurements and simulations were analyzed comprehensively to establish the reliability of the modeling process. Following this, we modeled both classrooms with the above mentioned daylighting systems

  7. Daylighting Strategies Promote Healthy High Performance Buildings

    Science.gov (United States)

    Gille, Steve

    2010-01-01

    There are many reasons to incorporate daylighting into the building or renovation of K-16 learning facilities. Benefits include increased productivity for students and staff, improved health, a better connection to the outdoors, energy savings and better quality of light. Add the role daylighting can play in LEED certification and it's clear that…

  8. Evaluation of Daylight Availability for Energy Savings

    Directory of Open Access Journals (Sweden)

    Laura Bellia

    2015-06-01

    Full Text Available Dynamic daylight simulations are very useful instruments in daylighting design process. They allow an in depth analysis of indoor daylight availability levels and define if they are adequate to perform a particular visual task. Their results can be used to design shading devices or lighting control systems and compare different technical solutions. The use of these simulations is likely to spread in the common design practice since some regulations and green building rating systems suggest their use. This paper presents dynamic daylight simulation results related to an open-plan office, performed with Autodesk 3ds Max Design®, which is a calculation software validated by recent researches. It is not used in academic context but it is very widespread between technicians for photorenderings production purposes. The goal of this research is to demonstrate the functionality of this software also in dynamic daylight simulations field and propose an analysis' methodology to use it.

  9. Understanding Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  10. Daylighting System Based on Novel Design of Linear Fresnel lens

    Directory of Open Access Journals (Sweden)

    Thanh Tuan Pham

    2017-10-01

    Full Text Available In this paper, we present a design and optical simulation of a daylighting system using a novel design of linear Fresnel lens, which is constructed based on the conservation of optical path length and edge ray theorem. The linear Fresnel lens can achieve a high uniformity by using a new idea of design in which each groove of the lens distributes sunlight uniformly over the receiver so that the whole lens also uniformly distributes sunlight over the receiver. In this daylighting system, the novel design of linear Fresnel lens significantly improves the uniformity of collector and distributor. Therefore, it can help to improve the performance of the daylighting system. The structure of the linear Fresnel lenses is designed by using Matlab. Then, the structure of lenses is appreciated by ray tracing in LightToolsTM to find out the optimum lens shape. In addition, the simulation is performed by using LightToolsTM to estimate the efficiency of the daylighting system. The results show that the designed collector can achieve the efficiency of ~80% with the tolerance of ~0.60 and the concentration ratio of 340 times, while the designed distributor can reach a high uniformity of >90%.

  11. Daylight and absenteeism--evidence from Norway.

    Science.gov (United States)

    Markussen, Simen; Røed, Knut

    2015-01-01

    Based on administrative register data from Norway, we examine the impact of hours of daylight on sick-leave absences among workers. Our preferred estimates imply that an additional hour of daylight increases the daily entry rate to absenteeism by 0.5 percent and the corresponding recovery rate by 0.8 percent, ceteris paribus. The overall relationship between absenteeism and daylight hours is negative. Absenteeism is also sensitive to weather conditions. Heavy snowfall raises the incidence of absence during the winter, while warm weather reduces the probability of returning to work during the summer. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Solar shading for low energy use and daylight quality in offices: Simulations, measurements and design tools

    Energy Technology Data Exchange (ETDEWEB)

    Dubois, M.C.

    2001-11-01

    This thesis investigates the impact of solar shading devices on energy use and daylight quality in office rooms. The impact on energy use is analysed through computer simulations with the dynamic energy simulation program Derob-LTH while the impact on daylight quality is investigated through measurements in full-scale experimental office rooms and simulations with the program Radiance. This thesis also includes a literature review of research on solar shading as well as design tools to incorporate shading devices at an early stage in the design of buildings. This thesis indicates that, in cold countries, shading devices may provide more annual energy savings than any solar-protective (reflective, tinted) glazing and that the optimum glazing transmittance is orientation- and climate-dependent. For example, high annual energy savings are obtained on the south facade with higher transmittance glazings (compared with the east and west facade) because the potential for passive solar gain utilisation in the winter is high in comparison with the annual cooling demand. Exterior shading devices like awnings and overhangs may reduce the cooling demand dramatically but they are not suitable as daylight (glare) control devices. Devices like screens and venetian blinds are preferable because they cover the entire window area, which prevents sunlight patches in the room and the direct view of the bright sky. Screens and venetian blinds also reduce daylight in the room to levels that are suitable for computer work. However, it is essential that the screen is of a diffusing type since screens with a strong (specular) transmittance component result in poor daylight quality. The study on daylight quality also indicated that a screen transmittance of around 15 % may be optimum for a standard (3.5 by 6.0 m{sup 2}) south-oriented office room with a window covering around 25 % of the facade area (12 % of the floor area)

  13. Daylight calculations using constant luminance curves

    Energy Technology Data Exchange (ETDEWEB)

    Betman, E. [CRICYT, Mendoza (Argentina). Laboratorio de Ambiente Humano y Vivienda

    2005-02-01

    This paper presents a simple method to manually estimate daylight availability and to make daylight calculations using constant luminance curves calculated with local illuminance and irradiance data and the all-weather model for sky luminance distribution developed in the Atmospheric Science Research Center of the University of New York (ARSC) by Richard Perez et al. Work with constant luminance curves has the advantage that daylight calculations include the problem's directionality and preserve the information of the luminous climate of the place. This permits accurate knowledge of the resource and a strong basis to establish conclusions concerning topics related to the energy efficiency and comfort in buildings. The characteristics of the proposed method are compared with the method that uses the daylight factor. (author)

  14. Welcome to the Journal of Daylighting

    Directory of Open Access Journals (Sweden)

    Irfan Ullah

    2014-12-01

    Full Text Available I am delighted to welcome you to a newly launched Solarlits electronic journal: the Journal of Daylighting (JD. As the Editor-in-Chief of JD it is a great pleasure to introduce the inaugural issue of this new, open-access, bi-annual journal to readers, researchers, future authors, and colleagues. The decision by SolarLits to launch this new journal is very timely. Because the growth of lighting demand is increasing due to rising average illuminance levels in buildings, more attention has been paid to introduce daylighting in buildings, which will sustainably reduce the overall energy consumption in buildings. JD will serve as a new international platform for researchers to share advances in daylighting. As an international, peer-reviewed research journal it will exclusively cover the vibrant and diverse field of daylighting technologies and applications. JD will serve as an interdisciplinary forum for the scientific and research community active in daylighting and its applications. Topics will include, but not limited to: daylighting and hybrid lighting systems, lighting and daylighting simulation, lighting designs, lighting metrology and light quality, lighting control, building physics - lighting, building energy modeling, energy efficient buildings, zero-energy buildings, indoor environment quality, sustainable solar energy systems, application of solar energy sources in buildings, building-integrated photovoltaics, and solar thermal and concentrator technology. I will work with the Associate Editors, the Editorial Board, and the scientific and engineering research community to make JD a primary journal for the dissemination of breakthrough results, discussion of key challenges, and topics in daylighting. JD will publish full-length research articles, review articles, book reviews, and short communications.

  15. Effect of internal woven roller shade and glazing on the energy and daylighting performances of an office building in the cold climate of Shillong

    International Nuclear Information System (INIS)

    Singh, Ramkishore; Lazarus, I.J.; Kishore, V.V.N.

    2015-01-01

    Highlights: • We simulated a number of glazing and interior roller shade alternatives. • Office room has been simulated for three window-to-wall ratios in a cold climate. • Daylighting and energy performances have been assessed for each alternative. • Maximum energy savings have been estimated in the office with a 30% glazed area. • Energy saving decreases for larger glazed area and fabric transmittance. - Abstract: The energy and visual performances of the façades are defined by many parameters including façade size, properties of glazings and shadings, and their arrangements as well as control strategies. In this study, a number of combinations of internal woven roller shades and four double glazings have been proposed and assessed in integrated manner in order to improve the energy efficiency and visual comfort in new or existing office buildings. Office rooms facing south, east, north and west have been simulated for cold climate, by varying glazed areas and proposed glazing and shading alternatives. Results have been calculated, compared and analyzed in terms of the energy consumptions, energy saving potentials, daylight autonomy, useful daylight illuminance and discomfort glare free time, for each of the combinations. Simulation results show that the choice of glazing and shading alternatives can have substantial impact on energy and visual performances of the office space. Regardless of façade orientation, the maximum energy saving is achieved for a window-to-wall ratio (WWR) of 30%. Saving potential decreases significantly for larger glazed area and for each façade orientation. For all façade orientations and glazed areas (except for 30% WWR in the north wall), a bare low-e coated double glazing (U = 1.616 W/m"2 K, SHGC = 0.209, τ_v = 0.301) is found to be the most energy efficient choice. For 30% north glazing, the energy efficiency can be maximized with a different bare low-e coated double glazing (U = 1.628 W/m"2 K, SHGC = 0.370, τ_v = 0

  16. Windows and lighting program

    Energy Technology Data Exchange (ETDEWEB)

    1990-06-01

    More than 30% of all energy use in buildings is attributable to two sources: windows and lighting. Together they account for annual consumer energy expenditures of more than $50 billion. Each affects not only energy use by other major building systems, but also comfort and productivity -- factors that influence building economics far more than does direct energy consumption alone. Windows play a unique role in the building envelope, physically separating the conditioned space from the world outside without sacrificing vital visual contact. Throughout the indoor environment, lighting systems facilitate a variety of tasks associated with a wide range of visual requirements while defining the luminous qualities of the indoor environment. Windows and lighting are thus essential components of any comprehensive building science program. Despite important achievements in reducing building energy consumption over the past decade, significant additional savings are still possible. These will come from two complementary strategies: (1) improve building designs so that they effectively apply existing technologies and extend the market penetration of these technologies; and (2) develop advanced technologies that increase the savings potential of each application. Both the Windows and Daylighting Group and the Lighting System Research Group have made substantial contributions in each of these areas, and continue to do so through the ongoing research summarized here. 23 refs., 16 figs.

  17. Technology Assessments of High Performance Envelope with Optimized Lighting, Solar Control, and Daylighting

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Eleanor S.; Thanachareonkit, Anothai; Touzani, Samir; Dutton, Spencer; Shackelford, Jordan; Dickerhoff, Darryl; Selkowitz, Stephen

    2016-09-01

    The objective of this monitored field study was to identify near-term innovative façade technologies for solar control and daylighting with a goal of 20-40% energy use savings below Title 24 2013 in the 30-ft deep perimeter zone near vertical windows within cost and comfort constraints. The targeted market was new or existing commercial office buildings or buildings with similar patterns of use.

  18. Modeling daylight from solar irradiation in Malaysia

    International Nuclear Information System (INIS)

    Ahmed, A.Z.; Sayigh, A.A.K.; Surendran, P.N.; Othman, M.Y.

    1999-01-01

    The oil crises in the seventies, the environmental impact by the extensive use of energy in the nineties and the recent economic recession in Asia have led to the rediscovery of the use of daylight in energy-conscious design in buildings, the economic implication of the excessive use of artificial lighting in potential of daylight. No daylight data is currently available in Malaysia and therefore there is a need to model the daylight availability based on other climatic parameters measured at meteorological stations. A study has been carried out to produce daylight data from measured climatic parameters, specifically solar irradiation and could cover. The Model Year Climate (MYC) data for the location of Subang (3 deg. 7', N 101 deg. 33' E), model to estimate daily diffuse irradiation was produced the average values of global (KG) and diffuse (KD) luminous efficacious were calculated and found to be 112 lm/W and 120 lm/W respectively. The value of 104 lm/W for the beam luminous efficacy (KB) was selected. Using cloud data cover data as input parameters, the nebulosity index was calculated to determine the sky condition in Subang, Malaysia, which was then classified as average or intermediate sky type, the hourly illuminance on horizontal and inclined surfaces at locations with similar sky conditions in Malaysia were then produced. (author)

  19. Windows 10 for dummies

    CERN Document Server

    Rathbone, Andy

    2015-01-01

    The fast and easy way to get up and running with Windows 10 Windows 10 For Dummies covers the latest version of Windows and gets you up and running with the changes and new features you'll find in this updated operating system. Packed with time-saving tips to help you get the most out of the software, this helpful Windows 10 guide shows you how to manage Windows tasks like navigating the interface with a mouse or touchscreen, connecting to the web, and troubleshooting problems and making quick fixes. Assuming no prior knowledge of the software, Windows 10 For Dummies addresses the updates to

  20. The role of fenestration in promoting daylight performance. The mosques of Alexandria since the 19th century

    Directory of Open Access Journals (Sweden)

    Ingy I. El-Darwish

    2016-12-01

    Full Text Available Mosques have always been sacred places with distinctive sustainable environments. Fenestration in the prayers’ zone whether clerestories, screened windows, dome lighting and other light features have managed to produce significant spiritual human comfort areas. This paper focuses on fenestration of divine mosques and relates them to promoting daylight performance. The research process emphasizes the importance of daylight performance by promoting simulation tools on historical mosques of Alexandria since the 19th century that has witnessed change over time. The paper is a step toward sustainable lighting schemes in prayers’ zones that help to achieve human comfort as well as minimize use of energy. This study aimed at investigating the daylight performance by the use of climate based daylighting metrics which is “Daylight Autonomy” (DA. Daylight Autonomy is evaluated in the year round for the day lighted prayer periods to evaluate the behavior of fenestration of the different selected sample of mosques since the 19th century in Alexandria on a simulation tool in order to check whether it complies with the required illuminate and glare levels. The research findings are an attempt to lead to performative design guidelines introducing a contemporary interpretation for use in enhancing new designs of these holistic buildings.

  1. Daylighting for energy conservation in an existing building under tropical climate conditions: a case study of Lai Sue Thai building Ramkhamhaeng University

    Directory of Open Access Journals (Sweden)

    Lerdlekha Tanachaikhan

    2015-12-01

    Full Text Available Daylighting using skylight has been shown to have a high potential in reducing electrical lighting energy, and could provide a more pleasant atmosphere of a daylit space. However, in hot climates, the main constraint of daylighting is the solar heat gain that contributes to major heat load for an air-conditioning system. If the balance between the beneficial light gain used to offset lighting energy requirement and heat gain from daylight is well considered, significant energy savings can be obtained. The main objective of the study is to evaluate the potential of daylighting for energy conservation in the tropics through theoretical analysis (simulation study and experimental observation. Lai Sue Thai Building (an existing and educational building located at Ramkhamkaeng University was selected as a case study. From analysis, use of daylight could reduce electrical energy in this building by up to 76% compared to the initial condition where fully lighting was supplied. Window orientation would also play an important role. Moreover, heat gain through windows due to daylighting can be controlled by overhangs and the appropriate Window-to-Wall ratio that would be about 30% for this building. An experimental study was also carried out to validate the results in a selected room. About 49% and 37% of Relative Root Mean Square Error (RRMSE were observed in light and heat measurements, respectively

  2. Comparative Study of Daylighting Calculation Methods

    Directory of Open Access Journals (Sweden)

    Mandala Ariani

    2018-01-01

    Full Text Available The aim of this study is to assess five daylighting calculation method commonly used in architectural study. The methods used include hand calculation methods (SNI/DPMB method and BRE Daylighting Protractors, scale models studied in an artificial sky simulator and computer programs using Dialux and Velux lighting software. The test room is conditioned by the uniform sky conditions, simple room geometry with variations of the room reflectance (black, grey, and white color. The analyses compared the result (including daylight factor, illumination, and coefficient of uniformity value and examines the similarity and contrast the result different. The color variations trial is used to analyses the internally reflection factor contribution to the result.

  3. THE CASE FOR DAYLIGHTING IN ARCHITECTURE

    Directory of Open Access Journals (Sweden)

    Barrett Richard

    2009-07-01

    Full Text Available The paper discusses the reasons for using daylight in the design of architectural form and space. These reasons extend from those of a practical nature, including energy conservation, cost factors, and health and wellbeing, to those of a more intangible, aesthetic nature. Some historical precedents are offered as examples of projects in which designing to maximize daylighting was crucial in the mind of the architect. By contrast there is also discussion relating to the ‘the lost art’ of using natural lighting in architecture. Some of the reasons for this loss of conviction and expertise are considered. The place of national building codes and other statutory requirements is examined, as is the role of the architect and his/her relationship with other professionals involved in daylighting design in architecture.

  4. Flat Optical Fiber Daylighting System with Lateral Displacement Sun-Tracking Mechanism for Indoor Lighting

    Directory of Open Access Journals (Sweden)

    Ngoc Hai Vu

    2017-10-01

    Full Text Available An essential impact which can improve the indoor environment and save on power consumption for artificial lighting is utilization of daylight. Optical fiber daylighting technology offers a way to use direct daylight for remote spaces in a building. However, the existing paradigm based on the precise orientation of sunlight concentrator toward the Sun is very costly and difficult to install on the roof of buildings. Here, we explore an alternative approach using mirror-coated lens array and planar waveguide to develop a flat optical fiber daylighting system (optical fiber daylighting panel with lateral displacement Sun-tracking mechanism. Sunlight collected and reflected by each mirror-coated lens in a rectangular lens array is coupled into a planar waveguide using cone prisms placed at each lens focus. This geometry yields a thin, flat profile for Sunlight concentrator. Our proposed concentrating panel can be achieved with 35 mm thickness while the concentrator’s width and length are 500 mm × 500 mm. The commercial optical simulation tool (LightToolsTM was used to develop the simulation models and analyze the system performance. Simulation results based on the designed system demonstrated an optical efficiency of 51.4% at a concentration ratio of 125. The system can support utilizing a lateral displacement Sun-tracking system, which allows for replacing bulky and robust conventional rotational Sun-tracking systems. This study shows a feasibility of a compact and inexpensive optical fiber daylighting system to be installed on the roof of buildings.

  5. The Dynamics of Daylighting at a Residential College Building with the Internal Courtyard Arrangement

    Directory of Open Access Journals (Sweden)

    Adi Ainurzaman Jamaludin

    2015-11-01

    Full Text Available Dayasari residential college building was designed with the internal courtyard that allows for numerous implementations of bioclimatic design strategies, especially on daylighting. The field measurement was conducted at eight unoccupied student rooms, selected as samples to represent ten scenarios and orientations that concerned with the level of radiation and penetration of sunlight. This study reveals the contribution of the internal courtyard in the residential college which allows the daylight penetration at the corridor areas and interior of the rooms through the transom over the entrance door, up to ten hours daily. Different amounts of daylight were measured in specific room scenarios to suggest on the most comfortable indoor living space. The recorded mean value for indoor varied from 37 to 286 lux, while in the corridor area 192 to 3,848 lux. However, the use of the large overhangs over the windows, wall openings in the room and trees with large canopy in the landscape setting should critically justify when the adequacy of daylight was drastically reduced in certain rooms.

  6. Weather conditions and daylight-mediated photodynamic therapy

    DEFF Research Database (Denmark)

    Wiegell, S R; Fabricius, S; Heydenreich, J

    2013-01-01

    Photodynamic therapy (PDT) is an attractive therapy for nonmelanoma skin cancers and actinic keratoses (AKs). Daylight-mediated methyl aminolaevulinate PDT (daylight-PDT) is a simple and painless treatment procedure for PDT. All daylight-PDT studies have been performed in the Nordic countries...

  7. Windows Azure

    CERN Document Server

    Johnson, Bruce; Chambers, James; Garber, Danny; Malik, Jamal; Fazio, Adam

    2013-01-01

    A collection of five must-have Azure titles, from some of the biggest names in the field Available individually, but at a discounted rate for the collection, this bundle of five e-books covers key developer and IT topics of Windows Azure, including ASP.NET, mobile services, web sites, data storage, and the hybrid cloud. A host of Microsoft employees and MPVs come together to cover the biggest challenges that professionals face when working with Windows Azure. The e-books included are as follows: Windows Azure and ASP.NET MVC MigrationWindows Azure Mobile ServicesWindows Azure Web SitesWindows

  8. The effect of dynamic solar shading on energy, daylighting and thermal comfort in a nearly zero-energy loft room in Rome and Copenhagen

    DEFF Research Database (Denmark)

    Skarning, Gunnlaug Cecilie Jensen; Hviid, Christian Anker; Svendsen, Svend

    2017-01-01

    alternatives in buildings with very low space-heating demand, this study mapped and compared energy, daylighting and thermal comfort for various combinations of window size and glazing properties, with and without dynamic shading. The study considered a loft room with sloped roof windows and moderate venting...... as defined by the Adaptive Thermal Comfort (ATC) model....... options in nearly zero-energy homes in Rome and Copenhagen. The more flexible solution space with dynamic shading made it possible to either reduce the time with operative temperatures exceeding the comfort limit by 40–50 h or increase daylighting by 750–1000 h more than could be achieved without shading...

  9. Application and Computer Analysis of Solar Systems for the Indoor Daylighting

    Energy Technology Data Exchange (ETDEWEB)

    Makhmudov, Is Kandar

    2010-02-15

    A steady increase of energy costs and ever growing environmental concerns in recent years have forced scientists to look for new methods of energy utilization. To resolve these dire problems, the application of renewable energy sources has been considered in various human activities in every sector of society. One of them is the development of solar daylighting systems for residential and commercial buildings, which can improve building energy efficiency and create comfortable indoor environment. Electric lighting represents up to 30 % of building electricity consumption. Therefore, using sunlight in indoor daylighting can significantly reduce electricity consumption in residential and commercial buildings. Moreover, daylight is an important factor in visual environment and improving human well-being. In last decades, different approaches to the design of solar daylighting systems have resulted in various innovative solutions to efficiently introduce natural light in buildings. But their efficiency and cost are still one of primary obstacles in the wider development and distribution of solar daylighting systems. In this study, we investigated the performance of a new solar concentrator system for indoor illumination. The solar concentrator system consists of 30 cm dish concentrators, high precision solar trackers, optical fibers and diffusers for a light distribution. In order to assess the daylighting system's efficiency, there were carried out several experimental measurement series. One of them was an application of our solar daylighting system to two standard classrooms with south- and north-oriented windows in Jeju city, Korea. At the same time classrooms were modeled by using ECOTECT and exported to RADIANCE for daylighting simulations. Results from the measurements and simulations were analyzed comprehensively to establish the reliability of the modeling process. Following this, we modeled both classrooms with the above mentioned daylighting systems

  10. Window Stories

    DEFF Research Database (Denmark)

    Hauge, Bettina

    This research project has investigated 17 households in Germany (cities and rural areas). The main aim was to learn about the significance of the window to these people: What they think of their windows, how, when and why they use them in their everyday life, if they have a favorite window and wh...

  11. Analysis of daylight calculated using the EnergyPlus programme

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Greici; Ghisi, Enedir [Universidade Federal de Santa Catarina, Departamento de Engenharia Civil, Laboratorio de Eficiencia Energetica em Edificacoes, Caixa Postal 476, Florianopolis - SC 88040-900 (Brazil)

    2010-09-15

    In order to properly evaluate the thermal energy performance of buildings it is also necessary to analyse the use of daylight, since this influences the thermal load of a building. In this context, the aim of this study was to evaluate the calculation of internal illuminances carried out using the EnergyPlus simulation programme. The analysis was carried out through a comparison of the Useful Daylight Illuminances (UDI) and the daylight factor (DF) estimated using the EnergyPlus programme with the results from another two programmes: Daysim/Radiance and TropLux. Also, the external horizontal illuminance estimated using EnergyPlus was compared with that measured in Florianopolis, Santa Catarina State, Brazil, between 2003 and 2005. The simulations were carried out for three different rooms: one square (5 m x 5 m x 3 m), one shallow rectangular (10 m x 5 m x 3 m) and one deep rectangular (5 m x 10 m x 3 m). From this analysis it was verified that the EnergyPlus programme has a problem related to both the DF and the external illuminance values. A comparison between the DF values calculated using the three programmes shows that there is a problem in EnergyPlus related to solving the internal reflection, such that the greater the importance of the portion of light reflected, the greater the difference found between the programmes. A comparison between the calculated and measured external horizontal illuminances shows differences greater than 100% both for the diffuse and direct illuminances indicating that the EnergyPlus programme overestimates these values. (author)

  12. Daylight prediction techniques in energy design tools

    Energy Technology Data Exchange (ETDEWEB)

    Milne, M.; Zurick, J. [California Univ., Los Angeles, Dept. of Architecture, CA (United States)

    1998-09-01

    Four different whole-building energy design tool systems that calculate energy savings from daylighting and that display annual performance on an-hour-by-hour basis, have been tested. The nature of design tools, the sources of hourly outdoor illuminance data, the ways of predicting indoor illumination, the assumptions of each tool, and the resulting energy savings of the design tools tested are discussed. The tests were carried out with the essential criteria for evaluating whole-building daylighting and energy design tools in mind. These have been identified as user confidence, accuracy, response time, and the amount of detail. Results of the tests, all four of them run on a single elementary school classroom for the sake of comparability, were provided. 9 refs., 2 figs.

  13. Effectiveness of daylighting design and occupant visual satisfaction in a LEED gold laboratory building

    Energy Technology Data Exchange (ETDEWEB)

    Hua, Ying; Oswald, Anne [Department of Design and Environmental Analysis, Cornell University, Ithaca, NY 14853 (United States); Yang, Xiaodi [School of Architecture, Carnegie Mellon University, Pittsburgh, PA 15213 (United States)

    2011-01-15

    Using daylight as primary light source has been widely recognized as an important strategy to reduce building energy demand and enhance indoor environment quality. However, to design and operate a building to make full use of daylight, which is a dynamic light source, to meet diverse occupant needs remains a challenge. This paper reports a post-occupancy study of the visual environment in a laboratory building on a university campus, and puts a spotlight on the building occupants as it examines the effectiveness of the daylighting design and systems integration in creating a visual environment to support occupant comfort and satisfaction while reducing artificial lighting demand. Results show generally high satisfaction with daylit work environment and positive effect of the horizontal shading strategy. Issues about the integration between daylighting and electric lighting systems and level of occupant control are identified and discussed for improving the effectiveness of daylighting and enhancing the quality of the visual environment in the building of study. A multiple-tool methodology is developed and tested, which included occupant surveys, interviews, illuminance measurements, continuous data loggers, fisheye-lens camera and glare-identifying software, and documentation of spatial settings, systems features, and user behavior. (author)

  14. Daylighting simulation: methods, algorithms, and resources

    Energy Technology Data Exchange (ETDEWEB)

    Carroll, William L.

    1999-12-01

    This document presents work conducted as part of Subtask C, ''Daylighting Design Tools'', Subgroup C2, ''New Daylight Algorithms'', of the IEA SHC Task 21 and the ECBCS Program Annex 29 ''Daylight in Buildings''. The search for and collection of daylighting analysis methods and algorithms led to two important observations. First, there is a wide range of needs for different types of methods to produce a complete analysis tool. These include: Geometry; Light modeling; Characterization of the natural illumination resource; Materials and components properties, representations; and Usability issues (interfaces, interoperability, representation of analysis results, etc). Second, very advantageously, there have been rapid advances in many basic methods in these areas, due to other forces. They are in part driven by: The commercial computer graphics community (commerce, entertainment); The lighting industry; Architectural rendering and visualization for projects; and Academia: Course materials, research. This has led to a very rich set of information resources that have direct applicability to the small daylighting analysis community. Furthermore, much of this information is in fact available online. Because much of the information about methods and algorithms is now online, an innovative reporting strategy was used: the core formats are electronic, and used to produce a printed form only secondarily. The electronic forms include both online WWW pages and a downloadable .PDF file with the same appearance and content. Both electronic forms include live primary and indirect links to actual information sources on the WWW. In most cases, little additional commentary is provided regarding the information links or citations that are provided. This in turn allows the report to be very concise. The links are expected speak for themselves. The report consists of only about 10+ pages, with about 100+ primary links, but

  15. Performance of a daylight-redirecting glass-shading system

    DEFF Research Database (Denmark)

    Appelfeld, David; Svendsen, Svend

    2013-01-01

    to the original system. The visual comfort was evaluated by glare analysis and the redirected daylight did not cause an additional discomfort glare. The higher utilization of daylight can save 20% of the lighting energy. The thermal insulation of the fenestration was maintained, with slightly increased solar......This paper evaluates the daylighting performance of a prototype external dynamic shading and daylight-redirecting system, and the main focus is on the performance simulation. The demonstration project was carried out on a building with an open-plan office. Part of the original façade was replaced...... with the prototype façade. This layout allowed the use of the same orientation and surroundings for both façades. The working plane illuminance was measured over several months and the measurements were accompanied with annual daylight simulations. The prototype system improved the daylighting conditions compared...

  16. The effect of daylight saving time options on electricity consumption of Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Karasu, Servet [Rize University, Rize Vocational School, 53100, Rize (Turkey)

    2010-09-15

    Most of the developed countries in the world use Daylight Saving Time (DST) as an energy conservation method. This study focuses on the effects of DST on electrical lighting in the buildings in Turkey. Turkey might adjust its daylight saving time to decrease energy consumption. For this purpose, five scenarios are considered and compared to status quo. The scenario with a 30-minute forward shift to single DST from April to October, stands out as the best solution to conserve electricity across the entire country. The results of the study show that maximum saving is obtained in this scenario by at least 0.7% on the consumption of lighting electricity. (author)

  17. Programming Windows Azure

    CERN Document Server

    Krishnan, Sriram

    2010-01-01

    Learn the nuts and bolts of cloud computing with Windows Azure, Microsoft's new Internet services platform. Written by a key member of the product development team, this book shows you how to build, deploy, host, and manage applications using Windows Azure's programming model and essential storage services. Chapters in Programming Windows Azure are organized to reflect the platform's buffet of services. The book's first half focuses on how to write and host application code on Windows Azure, while the second half explains all of the options you have for storing and accessing data on the plat

  18. Hardware-in-the-Loop Modeling and Simulation Methods for Daylight Systems in Buildings

    Science.gov (United States)

    Mead, Alex Robert

    This dissertation introduces hardware-in-the-loop modeling and simulation techniques to the daylighting community, with specific application to complex fenestration systems. No such application of this class of techniques, optimally combining mathematical-modeling and physical-modeling experimentation, is known to the author previously in the literature. Daylighting systems in buildings have a large impact on both the energy usage of a building as well as the occupant experience within a space. As such, a renewed interest has been placed on designing and constructing buildings with an emphasis on daylighting in recent times as part of the "green movement.''. Within daylighting systems, a specific subclass of building envelope is receiving much attention: complex fenestration systems (CFSs). CFSs are unique as compared to regular fenestration systems (e.g. glazing) in the regard that they allow for non-specular transmission of daylight into a space. This non-specular nature can be leveraged by designers to "optimize'' the times of the day and the days of the year that daylight enters a space. Examples of CFSs include: Venetian blinds, woven fabric shades, and prismatic window coatings. In order to leverage the non-specular transmission properties of CFSs, however, engineering analysis techniques capable of faithfully representing the physics of these systems are needed. Traditionally, the analysis techniques available to the daylighting community fall broadly into three classes: simplified techniques, mathematical-modeling and simulation, and physical-modeling and experimentation. Simplified techniques use "rules-of-thumb'' heuristics to provide insights for simple daylighting systems. Mathematical-modeling and simulation use complex numerical models to provide more detailed insights into system performance. Finally, physical-models can be instrumented and excited using artificial and natural light sources to provide performance insight into a daylighting system

  19. Daylight Influence on Colour Design : Empirical Study on Perceived Colour and Colour Experience Indoors

    OpenAIRE

    Hårleman, Maud

    2007-01-01

    It is known that one and the same interior colouring will appear different in rooms with windows facing north or facing south, but it is not known how natural daylight from these two compass points affects perceived colour and the ways in which colour is experienced. The objective is to describe the perceived colours to be expected in rooms with sunlight and diffused light, and thus develop a tool for colour design. Two empirical investigations provide the basis for six attached papers. The m...

  20. Simulating the Daylight Performance of Complex Fenestration Systems Using Bidirectional Scattering Distribution Functions within Radiance

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Gregory; Mistrick, Ph.D., Richard; Lee, Eleanor; McNeil, Andrew; Jonsson, Ph.D., Jacob

    2011-01-21

    We describe two methods which rely on bidirectional scattering distribution functions (BSDFs) to model the daylighting performance of complex fenestration systems (CFS), enabling greater flexibility and accuracy in evaluating arbitrary assemblies of glazing, shading, and other optically-complex coplanar window systems. Two tools within Radiance enable a) efficient annual performance evaluations of CFS, and b) accurate renderings of CFS despite the loss of spatial resolution associated with low-resolution BSDF datasets for inhomogeneous systems. Validation, accuracy, and limitations of the methods are discussed.

  1. Proper Installation of Replacement Windows | Efficient Windows

    Science.gov (United States)

    Collaborative Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring

  2. Window Glazing Types | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  3. Window Frame Types | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  4. Performance Standards for Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  5. Benefits of Efficient Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  6. Assessing Window Replacement Options | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  7. Windows for New Construction | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  8. Window Operator Types | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  9. Optimum Design Parameters of Box Window DSF Office at Different Glazing Types under Sub Interval of Intermediate Sky Conditions (20-40 klux)

    Science.gov (United States)

    Elayeb, O. K.; Alghoul, M. A.; Sopian, K.; Khrita, N. G.

    2017-11-01

    Despite Double skin façade (DSF) buildings are widely deployed worldwide, daylighting strategy is not commonly incorporated in these buildings compare to other strategies. Therefore, further theoretical and experimental studies would lead to adopting daylighting strategy in DSF office buildings. The aim of this study is to investigate the daylighting performance of office building at different design parameters of box window DSF using different glazing types under sub interval of intermediate sky conditions (20-40) klux using the (IES VE) simulation tool from Integrated Environmental Solutions - Virtual Environment. The implemented design parameters are window wall ratio (WWR) of internal façade (10-100) %, cavity depth (CD) of DSF (1-2.5) m and different glazing types. The glazing types were selected from the list available in the (IES VE) simulation tool. After series of evaluations, bronze tinted coating (STOPSOL) is implemented for the exterior façade while clear float, clear reflective coating (STOPSOL), grey and brown tinted coating (Anti-sun float) and blue coating tinted (SUNCOOL float) are implemented for the interior façade. In this paper, several evaluation parameters are used to quantify the optimum design parameters that would balance the daylighting requirements of a box window DSF office versus sky conditions range (20-40) klux. The optimum design parameters of DSF office building obtained under different glazing types are highlighted as follows. When using bronze tinted coating (STOPSOL) for the exterior façade, the glazing types of interior façade that showed superior daylighting performance of DSF office at (CD of 1.0m with WWR of 70%), (CD of 1.5m with WWR of 70%), (CD of 2.0m with WWR of 70%) and (CD of 2.0m with WWR of 70%) are grey tinted coating (Anti-sun float), clear reflective coating (STOPSOL), brown tinted coating (Anti-sun float), and clear float glazing respectively. Blue Coating tinted (SUNCOOL float) of interior façade glazing

  10. A window into extreme longevity; the circulating metabolomic signature of the naked mole-rat, a mammal that shows negligible senescence.

    Science.gov (United States)

    Lewis, Kaitlyn N; Rubinstein, Nimrod D; Buffenstein, Rochelle

    2018-04-20

    Mouse-sized naked mole-rats (Heterocephalus glaber), unlike other mammals, do not conform to Gompertzian laws of age-related mortality; adults show no age-related change in mortality risk. Moreover, we observe negligible hallmarks of aging with well-maintained physiological and molecular functions, commonly altered with age in other species. We questioned whether naked mole-rats, living an order of magnitude longer than laboratory mice, exhibit different plasma metabolite profiles, which could then highlight novel mechanisms or targets involved in disease and longevity. Using a comprehensive, unbiased metabolomics screen, we observe striking inter-species differences in amino acid, peptide, and lipid metabolites. Low circulating levels of specific amino acids, particularly those linked to the methionine pathway, resemble those observed during the fasting period at late torpor in hibernating ground squirrels and those seen in longer-lived methionine-restricted rats. These data also concur with metabolome reports on long-lived mutant mice, including the Ames dwarf mice and calorically restricted mice, as well as fruit flies, and even show similarities to circulating metabolite differences observed in young human adults when compared to older humans. During evolution, some of these beneficial nutrient/stress response pathways may have been positively selected in the naked mole-rat. These observations suggest that interventions that modify the aging metabolomic profile to a more youthful one may enable people to lead healthier and longer lives.

  11. External perforated Solar Screens for daylighting in residential desert buildings: Identification of minimum perforation percentages

    KAUST Repository

    Sherif, Ahmed

    2012-06-01

    requirements of the majority of tested cases. Illuminance levels in the examined residential space were satisfactory in 83% of the near zone cases and 53% in the mid-length zone, while the far zone suites 40% of the cases. Screen influence on daylighting was found to be very much dependent on the orientation of the window and time of the day.In stage two, the percentage of annual " Daylight Availability" was very much related to screen perforation percentage. As perforation percentage decreased, the percentage of Daylit and Over lit spaces decreased. At the same time, Partially Daylit areas of the space increased with similar percentages irrespective of the orientation. As a result of the twofold research stages, it is recommended to utilize a minimum of 80% perforation percentages for spaces similar to the tested case in the South orientation.In stage three, an initial investigation suggests that the use of screens can significantly reduce the occurrence of glare phenomena. Also, it is suggested to study the efficiency of designing Solar Screens that have non-uniform perforation ratios. These could prove useful in improving the illuminance levels in the mid-length and far zones of the unsatisfactory cases.In conclusion, minimum perforation percentages for Solar Screens were presented for specific design cases that encompassed different orientations, seasons and time of the day. In addition, a tool that could be used by architects for based on required annual " Daylit" areas for the design of Solar Screens that effectively achieve functional needs was provided. © 2012 Elsevier Ltd.

  12. Does Daylight Savings Time encourage physical activity?

    Science.gov (United States)

    Zick, Cathleen D

    2014-07-01

    Extending Daylight Savings Time (DST) has been identified as a policy intervention that may encourage physical activity. However, there has been little research on the question of if DST encourages adults to be more physically active. Data from residents of Arizona, Colorado, New Mexico, and Utah ages 18-64 who participated in the 2003-2009 American Time Use Survey are used to assess whether DST is associated with increased time spent in moderate-to-vigorous physical activity (MVPA). The analysis capitalizes on the natural experiment created because Arizona does not observe DST. Both bivariate and multivariate analyses indicate that shifting 1 hour of daylight from morning to evening does not impact MVPA of Americans living in the southwest. While DST may affect the choices people make about the timing and location of their sports/recreational activities, the potential for DST to serve as a broad-based intervention that encourages greater sports/recreation participation is not supported by this analysis. Whether this null effect would persist in other climate situations is an open question.

  13. The cost efficiency of improved roof windows in two well-lit nearly zero-energy houses in Copenhagen

    DEFF Research Database (Denmark)

    Skarning, Gunnlaug Cecilie Jensen; Hviid, Christian Anker; Svendsen, Svend

    2017-01-01

    .The aim of this study was to quantify the scope for investing in improved roof window solutions inbuildings insulated to consume nearly zero-energy. Based on two single-family houses in Copenhagenwith typical roof windows and adequate daylighting, the study identified the prices at which various typesof......Roof windows are efficient and flexible daylight sources that are essential in certain types of houses if theyare to achieve sufficient daylighting throughout. Previous studies have indicated that, for such buildingsto meet nearly zero-energy targets in an easy and robust way without compromising...... roof window improvements would have to be made available to achieve the same cost efficiency asimproved insulation. If the improvements can be made available for less than these prices, the installationof improved roof windows would make it cheaper to construct well-lit and comfortable nearly zero...

  14. Integrated performance appraisal of Daylight-Europe case study buildings

    NARCIS (Netherlands)

    Hensen, J.L.M.; Clarke, J.A.; Hand, J.W.; Johnson, K.; Wittchen, K.; Madsen, C.; Compagnon, R.

    1996-01-01

    This paper describes the approach taken within the EC’s Daylight-Europe project to apply combined thermal/daylight simulations to existing building designs which are representative of European types and climate contexts. The outputs from the performance appraisals are then incorporated within design

  15. New Liquid Crystal Smart Window and its Production Process (SmartWin II)

    DEFF Research Database (Denmark)

    Jensen, Karsten Ingerslev

    2005-01-01

    the operating modes don’t require energy consumption and where the transition from one to the other mode is fast (10 ms) thanks to an applied voltage or voltage pulse, 4) allowing a high solar factor modulation; a Solar Heat Gain Factor (SHGS) between 0.3 and 0.8.and a high daylight modulation between 0.1 and 0.......8, 5) with a good lifetime. The outcome of the project was: Several methods were developed and these allowed improving and realisation a number of lab-scale size (from 2 cm sq. up to 15 cm x 30 cm), active films with three optical states (clear, reflective or scattering state) to three original...... as well as realisation and scaling-up of switch-able patterned glass samples for smart windows. A market assessment study of smart windows have been carried out and by taking into account e.g. the fenestration markets, functionality and cost of currently available daylight systems, and it shows a very...

  16. Rails on Windows

    CERN Document Server

    Hibbs, Curt

    2007-01-01

    It's no secret that the entire Ruby onRails core team uses OS X as their preferreddevelopment environment. Becauseof this, it is very easy to findauthoritative information on the webabout using Rails on OS X. But the truthis that Windows developers using Railsprobably outnumber those using otherplatforms. A Windows development environmentcan be just as productive asany other platform. This is a guide to developing with Rubyon Rails under Windows. It won't teachyou how to write Ruby on Rails web applications,but it will show you what toolsto use and how to set them up to createa complete Rail

  17. Daylighting simulation : comparison of softwares for architect's utilization

    Energy Technology Data Exchange (ETDEWEB)

    Christakou, D.E.; Amorim, C.N.D. [Brazil Univ., Brasilia (Brazil). Faculty of Architecture and Urbanism

    2005-07-01

    This study analyzed and compared 4 daylighting software packages to determine the primary benefits and limits of each one, while considering the priorities for the use of the software by architects. The complex task of daylight simulation is an important step in designing buildings, particularly when the main objective is comfort and energy conservation. Simulation is not yet commonly practiced by professional architects because of the complexities of various software packages, the lack of user friendly interfaces and difficulty in interpreting results. The 4 software packages that were evaluated in this study were: (1) Desktop Radiance, (2) Rayfront, (3) Relux 2004 Vision, and (4) Lightscape. Criteria such as interfaces, flexibility, and help manuals were also analyzed in an effort to establish a frame of the main points to be considered when choosing daylighting software for architectural use, both in educational and office environments. Simulations of a test room were performed in which some parameters were modified to verify the performance of the following main criteria: flexibility in adapting to the architect's workflow; the use of state of the art algorithms; numerical precision; and, access possibility by Brazilian architects. The results demonstrate the potential of software's improvement, particular in terms of user interfaces and help manuals. The study showed that Relux 2004 Vision is the most adequate for architect's use. Rayfront and Desktop Radiance presented more difficulties in the design process, but Desktop Radiance had the advantage of being enclosed in AUTOCAD, a well known interface. Lightscape had a user friendly interface but was not as intuitive as Relux. It was concluded that the ideal daylighting simulation software does not yet exist. The ideal software should integrate diverse factors and combine edition and modeling tools beyond luminous evaluation and thermal consequences of daylight use. 5 refs., 3 tabs., 4 figs.

  18. Effects of daylight savings time changes on stock market volatility.

    Science.gov (United States)

    Berument, M Hakan; Dogan, Nukhet; Onar, Bahar

    2010-04-01

    The presence of daylight savings time effects on stock returns and on stock volatility was investigated using an EGARCH specification to model the conditional variance. The evidence gathered from the major United States stock markets for the period between 1967 and 2007 did not support the existence of the daylight savings time effect on stock returns or on volatility. Returns on the first business day following daylight savings time changes were not lower nor was the volatility higher, as would be expected if there were an effect.

  19. Light-scattering properties of a woven shade-screen material used for daylighting and solar heat-gain control

    Energy Technology Data Exchange (ETDEWEB)

    Jonsson, Jacob; Jonsson, Jacob C.; Lee, Eleanor S.; Rubin, Mike

    2008-08-01

    Shade-screens are widely used in commercial buildings as a way to limit the amount of direct sunlight that can disturb people in the building. The shade screens also reduce the solar heat-gain through glazing the system. Modern energy and daylighting analysis software such as EnergyPlus and Radiance require complete scattering properties of the scattering materials in the system. In this paper a shade screen used in the LBNL daylighting testbed is characterized using a photogoniometer and a normal angle of incidence integrating sphere. The data is used to create a complete bi-directional scattering distribution function (BSDF) that can be used in simulation programs. The resulting BSDF is compared to a model BADFs, both directly and by calculating the solar heat-gain coefficient for a dual pane system using Window 6.

  20. Resources | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  1. Links | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  2. Efficient Windows Collaborative | Home

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  3. FAQ | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  4. Glossary | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  5. effect of daylight hours on performance of growing grasscutters

    African Journals Online (AJOL)

    user

    DNA.Many animals use the daily variation in the duration and quantity of melatonin ... such as reproduction, behavior, coat growth and ... behavioral processes in the biological system. The ... spends the daylight hours sleeping or resting. The.

  6. Teaching Science: Beats the Daylight Out of Me.

    Science.gov (United States)

    Leyden, Michael B.

    1995-01-01

    Presents activities for observing, measuring, collecting, and graphing data about times of sunrise and sunset to teach an understanding about arrival of Daylight Savings Time in April. Also discusses seasonal affective disorder (SAD). (TM)

  7. Daylight savings time and myocardial infarction.

    Science.gov (United States)

    Sandhu, Amneet; Seth, Milan; Gurm, Hitinder S

    2014-01-01

    Prior research has shown a transient increase in the incidence of acute myocardial infarction (AMI) after daylight savings time (DST) in the spring as well as a decrease in AMI after returning to standard time in the fall. These findings have not been verified in a broader population and if extant, may have significant public health and policy implications. We assessed changes in admissions for AMI undergoing percutaneous coronary intervention (PCI) in the Blue Cross Blue Shield of Michigan Cardiovascular Consortium (BMC2) database for the weeks following the four spring and three fall DST changes between March 2010 and September 2013. A negative binomial regression model was used to adjust for trend and seasonal variation. There was no difference in the total weekly number of PCIs performed for AMI for either the fall or spring time changes in the time period analysed. After adjustment for trend and seasonal effects, the Monday following spring time changes was associated with a 24% increase in daily AMI counts (p=0.011), and the Tuesday following fall changes was conversely associated with a 21% reduction (p=0.044). No other weekdays in the weeks following DST changes demonstrated significant associations. In the week following the seasonal time change, DST impacts the timing of presentations for AMI but does not influence the overall incidence of this disease.

  8. Window shopping

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    'A large window for surprises' was how Gordon Kane of Michigan summarized the potential of the proposed 84-kilometre US Superconducting Supercollider (SSC). With George Trilling of Berkeley unable to attend this year's High Energy Physics Conference at Vanderbilt University, Nashville, Tennessee, from 8-10 October, Kane played a dual role - looking ahead to SSC physics, and summarizing the meeting

  9. Analysing the impact of reflectance distributions and well geometries on vertical surface daylight levels in atria for overcast skies

    Energy Technology Data Exchange (ETDEWEB)

    Du, Jiangtao; Sharples, Steve [School of Architecture, University of Sheffield, Crookesmoor Building, Conduit Road, Sheffield S10 1FL (United Kingdom)

    2010-07-15

    This study investigated the impacts of different diffuse reflectance distributions and well geometries on vertical daylight factors and vertical internally reflected components in atria. Two forms of reflectance distribution patterns of wall surface were examined: horizontal and vertical reflectance band variation. The square atrium models studied have a broader WI range of 0.25-2.0, which represent shallow, medium and high atria. Radiance, a powerful package based on backward ray tracing technique, was used for the simulations of vertical daylight levels. The results show that different reflectance distributions of square atrium walls do have an impact on the vertical daylight factors and vertical internally reflected components under overcast sky condition. The impact relates to the orientation of the band with different reflectance distributions on the wall. Compared with the vertical band surface, the horizontal band surface has a much more complicated effect. The horizontal distributions of the reflectances significantly affects the vertical daylight levels at the locations more than 30% atrium height on the wall. For an atrium with a height more than 1/2 the width, the effect tends to increase with the increasing well index. The vertical distributions of the reflectance, nevertheless, do not substantially take effect on the vertical daylight levels in atria except for some special reflectance distribution patterns. (author)

  10. Investigation of Educational Buildings in Terms of Daylighting Performance

    Directory of Open Access Journals (Sweden)

    İlknur ERLALELİTEPE

    2011-01-01

    Full Text Available Educational buildings have the priority among other building types in daylight performance studies. There are several reasons for this. Classrooms which are used during the whole day should have sufficient and homogeneously distributed daylight. In insufficient daylight conditions, the use of electrical lighting increases energy consumption. Users’ visual comfort should also be assured, and design incorporating natural light requires the analysis of sun protection devices in order to avoid glare and excessive heat. Also, atriums and skylights can be included in the building design with the aim of distributing light equally and in a relatively balanced manner throughout the building. However, lighting schemes are often proposed by architects and professionals who tend to make use of different design tools, and it would be pertinent to investigate whether these tools perform as desired. This study analyses daylight design principles and design elements in educational buildings. It outlines the method which has been used to analyse the daylight performance of buildings. A university building was selected for the field study. Measurements were taken in sample spaces to determine daylight performance. Utilising comparison between standard values and measured values, findings are presented in the form of tables, drawings and figures.

  11. Daylighting Design in Classroom Based on Yearly-Graphic Analysis

    Directory of Open Access Journals (Sweden)

    Yang Guan

    2016-07-01

    Full Text Available In China, existing buildings comprise more than 40 billion square meters, most being of high energy consumption. A substantial reduction in electrical energy costs could be obtained through greater use of daylight. Daylight varies widely due to the movement of sun, changing seasons and diverse weather conditions. Custom static daylight assessments, simulations represent only one time of the year or one time of the day, are inadequate to evaluate the dynamics of daylight variability. Using the intuitive graphic tool Temporal Map to display the annual daylight data, this study compared different passive architectural design strategies under the climate conditions of five representative Chinese cities and selected the most suitable design scheme for each city. In this study, the dynamic yearly-graphic tool was utilized for architectural design in China, and we integrated the optimal design with the Chinese academic calendar to achieve improvements within the occupancy time. This modified map connects design work with human activity that makes daylight evaluation more accurate and efficient. The results of this study will provide preliminary recommendations for energy-saving design in China, and reference to other similar studies.

  12. Light and architecture. Daylight - artificial light - energy; Licht und Architektur. Tageslicht - Kunstlicht - Energie

    Energy Technology Data Exchange (ETDEWEB)

    Wambsganss, M. (ed.) [ip5 ingenieurpartnerschaft, Karlsruhe (Germany)]|[Fachhochschule Rosenheim (Germany)

    2007-07-01

    The symposium intends to provide scientific and technical fundamentals for room lighting with daylight. Daylight deflection systems and artificial light control systems were analyzed for this purpose, and a catalogue of criteria was established. Planners were given tools for projecting daylight control systems. Builder-owners received the fundamentals for economic assessment of combined daylight and artificial light illumination systems, while industrial producers obtained information for further development to maturity and for marketing of daylight-dependent artificial light control systems. (GL)

  13. Light + architecture. Daylight - artificial light - energy; Licht + Architektur. Tageslicht - Kunstlicht - Energie

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-01

    The symposium intends to provide scientific and technical fundamentals for room lighting with daylight. Daylight deflection systems and artificial light control systems were analyzed for this purpose, and a catalogue of criteria was established. Planners were given tools for projecting daylight control systems. Builder-owners received the fundamentals for economic assessment of combined daylight and artificial light illumination systems, while industrial producers obtained information for further development to maturity and for marketing of daylight-dependent artificial light control systems. (GL)

  14. Using the Life Satisfaction Approach to Value Daylight Savings Time Transitions: Evidence from Britain and Germany

    OpenAIRE

    Daniel Kuehnle; Christoph Wunder

    2015-01-01

    Daylight savings time (DST) represents a public good with costs and benefits. We provide the first comprehensive examination of the welfare effects of the spring and autumn transitions for the UK and Germany. Using individual-level data and a regression discontinuity design, we estimate the effect of the transitions on life satisfaction. Our results show that individuals in both the UK and Germany experience deteriorations in life satisfaction in the first week after the spring transition. We...

  15. Strategic Windows

    DEFF Research Database (Denmark)

    Risberg, Annette; King, David R.; Meglio, Olimpia

    We examine the importance of speed and timing in acquisitions with a framework that identifies management considerations for three interrelated acquisition phases (selection, deal closure and integration) from an acquiring firm’s perspective. Using a process perspective, we pinpoint items within ...... acquisition phases that relate to speed. In particular, we present the idea of time-bounded strategic windows in acquisitions consistent with the notion of kairòs, where opportunities appear and must be pursued at the right time for success to occur....

  16. Window shopping

    OpenAIRE

    Oz Shy

    2013-01-01

    The terms "window shopping" and "showrooming" refer to the activity in which potential buyers visit a brick-and-mortar store to examine a product but end up either not buying it or buying the product from an online retailer. This paper analyzes potential buyers who differ in their preference for after-sale service that is not offered by online retailers. For some buyers, making a trip to the brick-and-mortar store is costly; however, going to the store to examine the product has the advantage...

  17. Effects of daylight-saving time changes on stock market volatility: a comment.

    Science.gov (United States)

    Kamstra, Mark J; Kramer, Lisa A; Levi, Maurice D

    2010-12-01

    In a recent article in this journal, Berument, Dogan, and Onar (2010) challenged the existence of the previously documented daylight-saving effect. Kamstra, Kramer, and Levi's original finding (2000) was that average stock market returns on Mondays following time changes are economically and statistically significantly lower than typical Monday returns. Kamstra, et al. hypothesized that the effect may arise due to heightened anxiety or risk aversion on the part of market participants after they experience a 1-hr. disruption in their sleep habits, in accordance with prior findings in the psychology literature linking sleep desynchronosis with anxiety. Berument, et al. replicated the original findings using ordinary least squares estimation, but when they modeled the mean of returns using a method prone to producing biased estimates, they obtained puzzling results. The analysis here, based on standard, unbiased modeling techniques, shows that the daylight-saving effect remains intact in the U.S.

  18. Mathematical model quantifies multiple daylight exposure and burial events for rock surfaces using luminescence dating

    DEFF Research Database (Denmark)

    Freiesleben, Trine Holm; Sohbati, Reza; Murray, Andrew

    2015-01-01

    Interest in the optically stimulated luminescence (OSL) dating of rock surfaces has increased significantly over the last few years, as the potential of the method has been explored. It has been realized that luminescence-depth profiles show qualitative evidence for multiple daylight exposure...... and burial events. To quantify both burial and exposure events a new mathematical model is developed by expanding the existing models of evolution of luminescenceedepth profiles, to include repeated sequential events of burial and exposure to daylight. This new model is applied to an infrared stimulated...... events. This study confirms the suggestion that rock surfaces contain a record of exposure and burial history, and that these events can be quantified. The burial age of rock surfaces can thus be dated with confidence, based on a knowledge of their pre-burial light exposure; it may also be possible...

  19. Windows Azure Platform

    CERN Document Server

    Redkar, Tejaswi

    2010-01-01

    The Azure Services Platform is a brand-new cloud-computing technology from Microsoft. It is composed of four core components-Windows Azure, .NET Services, SQL Services, and Live Services-each with a unique role in the functioning of your cloud service. It is the goal of this book to show you how to use these components, both separately and together, to build flawless cloud services. At its heart Windows Azure Platform is a down-to-earth, code-centric book. This book aims to show you precisely how the components are employed and to demonstrate the techniques and best practices you need to know

  20. Mathematical model quantifies multiple daylight exposure and burial events for rock surfaces using luminescence dating

    International Nuclear Information System (INIS)

    Freiesleben, Trine; Sohbati, Reza; Murray, Andrew; Jain, Mayank; Al Khasawneh, Sahar; Hvidt, Søren; Jakobsen, Bo

    2015-01-01

    Interest in the optically stimulated luminescence (OSL) dating of rock surfaces has increased significantly over the last few years, as the potential of the method has been explored. It has been realized that luminescence-depth profiles show qualitative evidence for multiple daylight exposure and burial events. To quantify both burial and exposure events a new mathematical model is developed by expanding the existing models of evolution of luminescence–depth profiles, to include repeated sequential events of burial and exposure to daylight. This new model is applied to an infrared stimulated luminescence-depth profile from a feldspar-rich granite cobble from an archaeological site near Aarhus, Denmark. This profile shows qualitative evidence for multiple daylight exposure and burial events; these are quantified using the model developed here. By determining the burial ages from the surface layer of the cobble and by fitting the new model to the luminescence profile, it is concluded that the cobble was well bleached before burial. This indicates that the OSL burial age is likely to be reliable. In addition, a recent known exposure event provides an approximate calibration for older daylight exposure events. This study confirms the suggestion that rock surfaces contain a record of exposure and burial history, and that these events can be quantified. The burial age of rock surfaces can thus be dated with confidence, based on a knowledge of their pre-burial light exposure; it may also be possible to determine the length of a fossil exposure, using a known natural light exposure as calibration. - Highlights: • Evidence for multiple exposure and burial events in the history of a single cobble. • OSL rock surface dating model improved to include multiple burial/exposure cycles. • Application of the new model quantifies burial and exposure events.

  1. How daylight influences high-order chromatic descriptors in natural images.

    Science.gov (United States)

    Ojeda, Juan; Nieves, Juan Luis; Romero, Javier

    2017-07-01

    Despite the global and local daylight changes naturally occurring in natural scenes, the human visual system usually adapts quite well to those changes, developing a stable color perception. Nevertheless, the influence of daylight in modeling natural image statistics is not fully understood and has received little attention. The aim of this work was to analyze the influence of daylight changes in different high-order chromatic descriptors (i.e., color volume, color gamut, and number of discernible colors) derived from 350 color images, which were rendered under 108 natural illuminants with Correlated Color Temperatures (CCT) from 2735 to 25,889 K. Results suggest that chromatic and luminance information is almost constant and does not depend on the CCT of the illuminant for values above 14,000 K. Nevertheless, differences between the red-green and blue-yellow image components were found below that CCT, with most of the statistical descriptors analyzed showing local extremes in the range 2950 K-6300 K. Uniform regions and areas of the images attracting observers' attention were also considered in this analysis and were characterized by their patchiness index and their saliency maps. Meanwhile, the results of the patchiness index do not show a clear dependence on CCT, and it is remarkable that a significant reduction in the number of discernible colors (58% on average) was found when the images were masked with their corresponding saliency maps. Our results suggest that chromatic diversity, as defined in terms of the discernible colors, can be strongly reduced when an observer scans a natural scene. These findings support the idea that a reduction in the number of discernible colors will guide visual saliency and attention. Whatever the modeling is mediating the neural representation of natural images, natural image statistics, it is clear that natural image statistics should take into account those local maxima and minima depending on the daylight illumination and

  2. Daylight Savings Time Transitions and the Incidence Rate of Unipolar Depressive Episodes.

    Science.gov (United States)

    Hansen, Bertel T; Sønderskov, Kim M; Hageman, Ida; Dinesen, Peter T; Østergaard, Søren D

    2017-05-01

    Daylight savings time transitions affect approximately 1.6 billion people worldwide. Prior studies have documented associations between daylight savings time transitions and adverse health outcomes, but it remains unknown whether they also cause an increase in the incidence rate of depressive episodes. This seems likely because daylight savings time transitions affect circadian rhythms, which are implicated in the etiology of depressive disorder. Therefore, we investigated the effects of daylight savings time transitions on the incidence rate of unipolar depressive episodes. Using time series intervention analysis of nationwide data from the Danish Psychiatric Central Research Register from 1995 to 2012, we compared the observed trend in the incidence rate of hospital contacts for unipolar depressive episodes after the transitions to and from summer time to the predicted trend in the incidence rate. The analyses were based on 185,419 hospital contacts for unipolar depression and showed that the transition from summer time to standard time were associated with an 11% increase (95% CI = 7%, 15%) in the incidence rate of unipolar depressive episodes that dissipated over approximately 10 weeks. The transition from standard time to summer time was not associated with a parallel change in the incidence rate of unipolar depressive episodes. This study shows that the transition from summer time to standard time was associated with an increase in the incidence rate of unipolar depressive episodes. Distress associated with the sudden advancement of sunset, marking the coming of a long period of short days, may explain this finding. See video abstract at, http://links.lww.com/EDE/B179.

  3. STUDI SIMULASI MODEL PENERANGAN ALAMI (DAYLIGHTING RUANG PADA BANGUNAN FASILITAS PENDIDIKAN TINGGI DENGAN SUPERLITE 2.0

    Directory of Open Access Journals (Sweden)

    Hanni Elitasari Mahaputri

    2012-08-01

    Full Text Available Daylight was the only efficient source of light available for building. Therefore, architecture was dominated by the goal of creating openings large enough to distribute daylight to building interiors. It is important to understand the amount of natural light penetration when outdoor obstruction are displaced in order to propose optimum external shading strategies as design solutions. This paper presents a study of the daylight factor and daylight contourt approaches and also investigates the effect of outdoor obstruction displacement on natural-light penetration of a specific room in higher-education building facility. The interior daylight illuminance data were simulated and analyzed using Superlite 2.0. The result shows that several effects of the external obstruction displacement as shading provider, depending on transmitted natural-light penetration, which determine the better consideration option in designing landscape surround building, especially in hot humid climates. Sinar matahari merupakan sumber penerangan yang efisien bagi bangunan. Tujuan utama dalam arsitektur adalah merancang bukaan pencahayaan yang cukup besar bagi bangunan untuk mendistribusikan cahaya ke bagian dalam bangunan. Sangat penting untuk mengetahui besar penetrasi penerangan alami yang masuk ke dalam ruang bila di luar bangunan diletakkan suatu halangan sebagai salah satu solusi disain dengan mengoptimalkan strategi perancangan pem­bayangan lingkungan. Makalah ini membahas tentang kajian pendekatan faktor penerangan alami (daylight factor dan koefisien penerangan alami, serta mengamati pengaruh perletakan halangan lingkungan terhadap penetrasi penerangan alami suatu ruang fasilitas pendidikan tinggi. Data illuminasi penerangan interior disimulasikan dan dianalisa menggunakan software Superlite 2.0. Hasil penelitian menunjukkan beberapa pengaruh perletakan halangan lingkungan sebagai elemen pembayangan lingkungan berkaitan dengan penetrasi cahaya alami, yang

  4. Daylight strategies for architectural studio facilities: the literature review

    Science.gov (United States)

    Othman, Muhammad Anas Bin; Azfahani Ahmad, Nur; Ajis, Azizah Md

    2017-05-01

    The implementation of daylighting strategies in buildings is a common aspect in architecture. However, due to the availability of inexpensive electricity, natural lighting strategies became insignificant, and been overlooked by designers. With the current concern over rapid increment on electricity cost, many designers now try to revitalized daylighting strategies in buildings. This includes educational buildings. In Malaysian cases, it is a norm that universities; especially during lecture and studio sessions, used artificial lighting throughout the day. Definitely, this is not parallel with the “green” aim made by the Government in the Malaysian Plan. Therefore, this paper aims to explore the impact of daylight strategies for educational studios in universities, by maximising the penetration of natural daylight into the space towards creating a more green-conducive studio. The paper review literature about the types, criteria and benefits of daylight strategies. This paper also presented a pilot study that has been performed in one university in Perak, Malaysia, by selecting architectural studios as the main subject.

  5. Autonomous physics-based color learning under daylight

    Science.gov (United States)

    Berube Lauziere, Yves; Gingras, Denis J.; Ferrie, Frank P.

    1999-09-01

    An autonomous approach for learning the colors of specific objects assumed to have known body spectral reflectances is developed for daylight illumination conditions. The main issue is to be able to find these objects autonomously in a set of training images captured under a wide variety of daylight illumination conditions, and to extract their colors to determine color space regions that are representative of the objects' colors and their variations. The work begins by modeling color formation under daylight using the color formation equations and the semi-empirical model of Judd, MacAdam and Wyszecki (CIE daylight model) for representing the typical spectral distributions of daylight. This results in color space regions that serve as prior information in the initial phase of learning which consists in detecting small reliable clusters of pixels having the appropriate colors. These clusters are then expanded by a region growing technique using broader color space regions than those predicted by the model. This is to detect objects in a way that is able to account for color variations which the model cannot due to its limitations. Validation on the detected objects is performed to filter out those that are not of interest and to eliminate unreliable pixel color values extracted from the remaining ones. Detection results using the color space regions determined from color values obtained by this procedure are discussed.

  6. The impact on energy consumption of daylight saving clock changes

    Energy Technology Data Exchange (ETDEWEB)

    Hill, S.I.; Desobry, F. [Department of Engineering, University of Cambridge (United Kingdom); Garnsey, E.W. [Institute for Manufacturing, University of Cambridge (United Kingdom); Chong, Y.-F. [IPA Energy and Water Consulting (United Kingdom)

    2010-09-15

    The focus of this work is an investigation of the effect of prevailing time regime on energy consumption. In particular we perform analysis demonstrating potential energy savings which could be obtained were Great Britain to maintain daylight savings time (DST) over winter, instead of reverting to Greenwich mean time (GMT). We review the literature on the effect of DST on energy consumption and show that this indicates a justification for considering the issue. Our headline result is in agreement with many related studies in that advancing the clock by an hour in winter would lead to energy savings of at least 0.3% of daily demand in Great Britain. In deriving this result we have adopted methodologies currently used in load prediction, in particular Support Vector Regression, to estimate energy demand on a half-hourly basis. Corresponding cost savings are found to be higher (due to the nonlinear increase of costs) and we find them to be on the order of 0.6% over the months considered. In terms of environmental impact we find the saving to be approximately equivalent to 450,000 ton of CO{sub 2}. In deriving these results we adopt a conservative approach such that we consider them lower bounds on any true savings. (author)

  7. The impact on energy consumption of daylight saving clock changes

    International Nuclear Information System (INIS)

    Hill, S.I.; Desobry, F.; Garnsey, E.W.; Chong, Y.-F.

    2010-01-01

    The focus of this work is an investigation of the effect of prevailing time regime on energy consumption. In particular we perform analysis demonstrating potential energy savings which could be obtained were Great Britain to maintain daylight savings time (DST) over winter, instead of reverting to Greenwich mean time (GMT). We review the literature on the effect of DST on energy consumption and show that this indicates a justification for considering the issue. Our headline result is in agreement with many related studies in that advancing the clock by an hour in winter would lead to energy savings of at least 0.3% of daily demand in Great Britain. In deriving this result we have adopted methodologies currently used in load prediction, in particular Support Vector Regression, to estimate energy demand on a half-hourly basis. Corresponding cost savings are found to be higher (due to the nonlinear increase of costs) and we find them to be on the order of 0.6% over the months considered. In terms of environmental impact we find the saving to be approximately equivalent to 450,000 ton of CO 2 . In deriving these results we adopt a conservative approach such that we consider them lower bounds on any true savings.

  8. Microsoft Windows networking essentials

    CERN Document Server

    Gibson, Darril

    2011-01-01

    The core concepts and technologies of Windows networking Networking can be a complex topic, especially for those new to the field of IT. This focused, full-color book takes a unique approach to teaching Windows networking to beginners by stripping down a network to its bare basics, thereby making each topic clear and easy to understand. Focusing on the new Microsoft Technology Associate (MTA) program, this book pares down to just the essentials, showing beginners how to gain a solid foundation for understanding networking concepts upon which more advanced topics and technologies can be built.

  9. New tools for the evaluation of daylighting strategies and technologies

    Energy Technology Data Exchange (ETDEWEB)

    Papamichael, K.; Hitchcock, R.; Ehrlich, C.; Carroll, B.

    1998-03-01

    The use of daylight for the illumination of building interiors has the potential to enhance the quality of the environment while providing opportunities to save energy by replacing or supplementing electric lighting. Moreover, it has the potential to reduce heating and cooling loads, which offer additional energy saving opportunities as well as reductions in HVAC equipment sizing and cost. All of these benefits, however, assume proper use of daylighting strategies and technologies, whose performance depends on the context of their application. On the other hand, improper use can have significant negative effects on both comfort and energy requirements, such as increased glare and cooling loads. To ensure proper use, designers need design tools that model the dynamic nature of daylight and accurately predict performance with respect to a multitude of performance criteria, extending beyond comfort and energy to include aesthetics, cost, security, safety, etc.

  10. Daylight levels during the solar eclipse of 11 August 1999

    Science.gov (United States)

    Darula, S.; Kambezidis, H. D.; Kittler, R.

    Solar eclipses are unique phenomena not only for astronomical and space observations but also for terrestrial; they create unique conditions of sunbeam blockage which cause not only the reduction of direct sunlight but also the dimming of skylight from the whole sky vault. Very favorable conditions were met during the recent August 1999 solar eclipse in Athens, Greece and Bratislava, Slovakia. General class daylight stations operate within the International Daylight Measurements Program in the two cities. One-minute data of global/diffuse illuminance and zenith luminance from those stations have been used to provide information about their levels and the daylight reduction rate during the eclipse. An approximate formula for the estimation of sunlight and skylight illuminance levels as well as zenith luminance using relative luminance sky patterns is also presented in this work. To achieve this, recently developed sky standards together with their parameterizations are utilized.

  11. Windows 7 the definitive guide

    CERN Document Server

    Stanek, William R

    2010-01-01

    This book provides everything you need to manage and maintain Windows 7. You'll learn all of the features and enhancements in complete detail, along with specifics for configuring the operating system to put you in full control. Bestselling author and Windows expert William Stanek doesn't just show you the steps you need to follow, he also tells you how features work, why they work, and how you can customize them to meet your needs. Learn how to squeeze every bit of power out of Windows 7 to take full advantage of its features and programs. Set up, customize, and tune Windows 7-Optimize its

  12. Cutaneous leishmaniasis responds to daylight-activated photodynamic therapy

    DEFF Research Database (Denmark)

    Enk, C D; Nasereddin, A; Alper, R

    2015-01-01

    BACKGROUND: Cutaneous leishmaniasis (CL) is endemic in Israel, with hundreds of new cases reported in recent years. Photodynamic therapy (PDT) is highly effective for treatment of CL, but requires equipment available only at specialized centres. Daylight-activated PDT (DA-PDT) abolishes the need...... application of a thick layer of 16% methyl aminolaevulinate and 30-min occlusion, the lesions were exposed to daylight for 2·5 h. Treatment sessions were repeated at weekly intervals until clinical and microbiological cure. Control lesions were either treated with cryotherapy or left untreated. RESULTS...

  13. Combined daylight and intelligent LED lighting - getting the daylight into the buildings; Kombineret dagslys og intelligent LED belysning - fae dagslys ind i bygningerne. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Dam-Hansen, C.; Corell, D.D.; Thorseth, A.; Behrensdorff Poulsen, P. [Technical Univ. of Denmark, DTU Fotonik, DTU Risoe Campus, Roskilde (Denmark); Markvart, J.; Iversen, A.; Logadottir, A. [Aalborg Univ., Statens Byggeforskningsinstitut (SBi), Koebenhavn (Denmark)

    2013-03-15

    The main result of the project is the construction of the new intelligent and dynamic LED lighting system for demonstration and research purposes, and a number of extensive user testing is completed. The LED lighting system is a total system for office lighting with ceiling fixtures and desk lamps, which has made it possible to create a general and workplace lighting in two offices each with two work places. The system is installed in a day light laboratory for such two office spaces. All lamps can be controlled via a developed computer interface, and the desk lamps are further manually controllable by a user via two buttons for color temperature and brightness, respectively. The new intelligent and dynamic lighting system is based on color mixing LED technology and makes it possible to control the color composition, color coordinates and thus the color temperature of the light. Control-wise, the system is pre-programmed to produce white light with a correlated color temperature from 2700 K to 7000 K. The color composition is optimized from the desire for a very good color given at a general CRI value of 92-97 over the area. The system can be dimmed 20-100 %, with no significant change in the light's color properties. A mini-spectrometer is calibrated and built-in in the system and provides the current estimate of daylight brightness and color temperature through measurement of daylight color scheme in the visible range. The system uses daylight properties to control the light from the LED lighting system. The results of user tests show, that the developed possibility to automatically control of light in the office depending on the daylight color temperature is considered to be equally preferred and results in equally satisfied users as a traditional lighting system with even lighting in the room. On the other hand, user results showed that there were both energy savings and more satisfied users to be gained by providing users the opportunity to self-adjust either

  14. Balancing the daylighting and energy performance of solar screens in residential desert buildings: Examination of screen axial rotation and opening aspect ratio

    KAUST Repository

    Sabry, Hanan

    2014-05-01

    performance criteria at the same time.This study confirmed the results of previous publications on the usefulness of using solar screens in desert environments. Solar screens could significantly enhance daylighting performance and visual comfort. They provided 66-97% "daylit" areas in the tested spaces. In addition, use of solar screens reduced energy consumption by up to 25% in comparison with a non-screened window. © 2014 Elsevier Ltd.

  15. The study on the computer analysis of solar daylighting system in the schoolroom

    Energy Technology Data Exchange (ETDEWEB)

    Oh, W. J.; Makhmudov, I.; Lee, Y. J.; Chun, W. G. [Jeju National University, Jeju (Korea, Republic of)

    2010-10-15

    Daylighting is the efficient use of natural light in order to minimize the need for artificial light in buildings. A well thought out building designed with daylighting can have a number of significant benefits for building owners and occupants. Increasing levels of daylight within rooms can reduce electrical lighting loads by up to 70% in some cases. In this study, the daylighting system using mini dish and optical fiber was analyzed for application to the schoolroom by the simulation of ECOTECT and RADIANCE

  16. Daylight savings time transitions and the incidence rate of unipolar depressive episodes

    DEFF Research Database (Denmark)

    Hansen, Bertel T; Sønderskov, Kim M; Hageman, Ida

    2017-01-01

    Background: Daylight savings time transitions affect approximately 1.6 billion people worldwide. Prior studies have documented associations between daylight savings time transitions and adverse health outcomes, but it remains unknown whether they also cause an increase in the incidence rate...... of depressive episodes. This seems likely because daylight savings time transitions affect circadian rhythms, which are implicated in the etiology of depressive disorder. Therefore, we investigated the effects of daylight savings time transitions on the incidence rate of unipolar depressive episodes. Methods...

  17. Predicting daylight illuminance on inclined surfaces using sky luminance data

    Energy Technology Data Exchange (ETDEWEB)

    Li, D.H.W.; Lau, C.C.S.; Lam, J.C. [City University of Hong Kong, Kowloon (China). Dept. of Building and Construction

    2005-07-01

    Daylight illuminance, particularly on vertical surfaces, plays a major role in determining and evaluating the daylighting performance of a building. In many parts of the world, however, the basic daylight illuminance data for various vertical planes are not always readily available. The usual method to obtain diffuse illuminance on tilted planes would be based on inclined surface models using data from the horizontal measurements. Alternatively, the diffuse illuminance on a sloping plane can be computed by integrating the luminance distribution of the sky 'seen' by the plane. This paper presents an approach to estimate the vertical outdoor illuminance from sky luminance data and solar geometry. Sky luminance data recorded from January 1999 to December 2001 in Hong Kong and generated by two well-known sky luminance models (Kittler and Perez) were used to compute the outdoor illuminance for the four principal vertical planes (N, E, S and W). The performance of this approach was evaluated against data measured in the same period. Statistical analysis indicated that using sky luminance distributions to predict outdoor illuminance can give reasonably good agreement with measured data for all vertical surfaces. The findings provide an accurate alternative to determine the amount of daylight on vertical as well as other inclined surfaces when sky luminance data are available. (author)

  18. Solar Shading System Based on Daylight Directing Glass Lamellas

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Santos, Inês; Svendsen, Svend

    2008-01-01

    The overheating problems in office buildings must be solved with efficient solar shadings in order to reduce the energy demand for cooling and ventilation. At the same time the solar shading should not reduce the daylight level in the building on overcast days because it would result in a lower...

  19. Daylight Saving Time Transitions and Road Traffic Accidents

    Directory of Open Access Journals (Sweden)

    Tuuli Lahti

    2010-01-01

    Full Text Available Circadian rhythm disruptions may have harmful impacts on health. Circadian rhythm disruptions caused by jet lag compromise the quality and amount of sleep and may lead to a variety of symptoms such as fatigue, headache, and loss of attention and alertness. Even a minor change in time schedule may cause considerable stress for the body. Transitions into and out of daylight saving time alter the social and environmental timing twice a year. According to earlier studies, this change in time-schedule leads to sleep disruption and fragmentation of the circadian rhythm. Since sleep deprivation decreases motivation, attention, and alertness, transitions into and out of daylight saving time may increase the amount of accidents during the following days after the transition. We studied the amount of road traffic accidents one week before and one week after transitions into and out of daylight saving time during years from 1981 to 2006. Our results demonstrated that transitions into and out of daylight saving time did not increase the number of traffic road accidents.

  20. The effect of different weather data sets and their resolution on climate-based daylight modelling

    DEFF Research Database (Denmark)

    Iversen, A; Svendsen, Svend; Nielsen, Toke Rammer

    2013-01-01

    Climate-based daylight modelling is based on the available weather data, which means that the weather data used as input to the daylight simulations are of great importance. In this paper, the effect on the outcome of the daylight simulations of using one weather data file rather than another...

  1. Windows forensic analysis toolkit advanced analysis techniques for Windows 7

    CERN Document Server

    Carvey, Harlan

    2012-01-01

    Now in its third edition, Harlan Carvey has updated "Windows Forensic Analysis Toolkit" to cover Windows 7 systems. The primary focus of this edition is on analyzing Windows 7 systems and on processes using free and open-source tools. The book covers live response, file analysis, malware detection, timeline, and much more. The author presents real-life experiences from the trenches, making the material realistic and showing the why behind the how. New to this edition, the companion and toolkit materials are now hosted online. This material consists of electronic printable checklists, cheat sheets, free custom tools, and walk-through demos. This edition complements "Windows Forensic Analysis Toolkit, 2nd Edition", (ISBN: 9781597494229), which focuses primarily on XP. It includes complete coverage and examples on Windows 7 systems. It contains Lessons from the Field, Case Studies, and War Stories. It features companion online material, including electronic printable checklists, cheat sheets, free custom tools, ...

  2. Simulation of Daylighting Conditions in a Virtual Underground City

    Directory of Open Access Journals (Sweden)

    Cristiano Merli Alcini

    2015-06-01

    Full Text Available From the Piranesi fantastic architectures to the animation movies and video games of the last thirty years, a new design approach has been introduced and developed: the design of the virtual space. Designing the "virtual" means experiencing a multidisciplinary approach where architecture, engineering, and urban planning meet the new horizons of information and communication technology. This study is focused on virtual space, which is an underground city. Mankind have always made and used underground environments: the possibilities of unlimited spaces to potential development, the reduced needs for raw materials for the construction and the protection from outdoor weather are some of the reasons that prompted humans to the realization of underground spaces in the past. These reasons and the availability of innovative technologies could encourage a breakthrough in the realization of new underground environments. A recent example is represented by the Underground City of Montreal (RÉSO. We present the architectural design of a virtual underground city, which is called Arch[ane], and its evaluation. The underground city is modular and the studied module is composed of eight floors with a total depth of 400 m and dimensions of 800 m × 800 m. The study comprises the evaluation of the effect of sunlight on each eight floors of the city. Daylighting simulations were performed considering different cities at different latitudes, days, and hours. The results have shown that the particular design of the underground city with skylights gives significant values of illuminance at a certain depth. Furthermore, the simulation results show how huge can be the potentialities of software to simulate extremely big environments.

  3. Natural Light is the Right Light - Daylighting Design and Technology between Architecture, Art and Sustainability

    DEFF Research Database (Denmark)

    Osterhaus, Werner

    2009-01-01

    Within contemporary architecture, the art of daylighting design ? despite its many recognized advantages in comparison with electric lighting ? still encounters skepticism, primarily because it is usually developed and articulated more intuitively, rather than technically. Innovative daylighting ...... daylighting design with an open mind and an appreciation for basic human needs....... applications have added sparkle and interest to buildings. The sun?s rays have been captured to create magnificent plays of forms in light. People perceive daylight as an essential element of life. But architects, lighting designers, and clients alike, often underestimate the importance of daylight for human...

  4. The costs and benefits of using daylight guidance to light office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Mayhoub, M.S.; Carter, D.J. [School of Architecture, University of Liverpool (United Kingdom)

    2011-03-15

    Daylight guidance systems are linear devices that channel daylight into the core of a building. This paper analyses costs and benefits of using the two main classes of daylight guidance to light offices as an alternative to conventional electric lighting. The work demonstrates that daylight guidance is generally not economical using conventionally accepted measures of both cost and benefit. It is shown that if intangible benefits associated with the delivery of daylight to offices are included in an analysis, a more favourable balance of cost and benefit is obtained. The implications of this for practical use of the systems are discussed. (author)

  5. Essence of Daylight in the Cistercian Monastic Church of S. Bento de Cástris, Évora, Portugal

    Science.gov (United States)

    Martins, Ana M. T.; Carlos, Jorge S.

    2017-10-01

    Natural light in the Cistercian churches is closely linked not only with the liturgical requirements at the “officium” but also with the canonical hours based on the "ora et labora" dictated by the Rule of St. Benedict. The Cistercian architecture, in its beginnings (12th century forward) is characterized by austerity, simplicity and the play of light and shadow that gives value to the monastic architectural space itself, making it perfect for a contemplative experience. In the Cistercian Monastery the church is the central piece of the monastic building. Nave, transept and apse are the main architectural components to which is added the choir. This paper contextualizes the importance and close connections of natural light, within the Cistercian Monasteries architecture. Thus the essence of daylight is analysed within the Church of the Monastery of S. Bento de Cástris, in Évora, Portugal. This former Monastery (13th - 19th centuries) includes the church, at the south-eastern corner which has not only a high choir, but also a low lateral choir (within the presbytery). Its unchanged exterior walls are made of solid masonry. Although the function of the walls is primarily structural, the windows allow the daylight to penetrate the space of the church. The church has two external façades facing northeast and southeast. The combined orientation effect of the church’s main axis and the sun trajectory determines how the sunlight reaches the interior of this architectural structure. This study presents the qualitative and quantitative analysis of the luminous environment in the church of S. Bento de Cástris, being the first based on the authors’ perception of the effect of the daylight within the different areas of the enclosed space. The appreciation of the spatial experiences was supported by quantitative daylight simulations that were conducted in selected areas within the space. With this paper is intended to contribute to the debate about the specificity

  6. Phases of daylight and the stability of color perception in the near peripheral human retina.

    Science.gov (United States)

    Panorgias, Athanasios; Kulikowski, Janus J; Parry, Neil R A; McKeefry, Declan J; Murray, Ian J

    2012-03-01

    Typical daylight extends from blue (morning sky) to orangey red (evening sky) and is represented mathematically as the Daylight Locus in color space. In this study, we investigate the impact of this daylight variation on human color vision. Thirty-eight color normal human observers performed an asymmetric color match in the near peripheral visual field. Unique hues were identified using a naming paradigm. The observers' performance for matching was almost perfectly coincident with the Daylight Locus but declined markedly in other regions. Interobserver variability reached a conspicuous minimum adjacent to the Daylight Locus and was maximal in the red and yellowish-green regions. In the naming task, unique blue and yellow were virtually coincident with the Daylight Locus. The results suggest that the mechanisms of color perception mediated by the phylogenetically older (blue-yellow) color pathway have been strongly influenced by the different phases of daylight.

  7. From dark to bright: novel daylighting applications in solid state lighting

    Science.gov (United States)

    Adler, Helmar G.

    2011-10-01

    The term "daylighting" is used in various ways, on one hand in a more architectural sense, i.e. using existing daylight to illuminate spaces, and on the other, more recently, for using light sources to replicate daylight. The emergence of solid state lighting (SSL) opens up a large number of new avenues for daylighting. SSL allows innovative controllability of intensity and color for artificial light sources that can be advantageously applied to daylighting. With the assistance of these new technologies the combination of natural and artificial lighting could lead to improvements in energy savings and comfort of living beings. Thus it is imperative to revisit or even improve daylighting research so that building networks of the future with their sensor, energy (e.g. HVAC) and lighting requirements can benefit from the emerging capabilities. This paper will briefly review existing daylighting concepts and technology and discuss new ideas. An example of a tunable multi-color SSL system will be shown.

  8. Does extending daylight saving time save energy? Evidence from an Australian experiment

    Energy Technology Data Exchange (ETDEWEB)

    Kellogg, R. [California Univ., Berkeley, CA (United States). Dept. of Agricultural and Resource Economics; Wolff, H. [California Univ., Berkeley, CA (United States). Dept. of Agricultural and Resource Economics]|[Forschungsinstitut zur Zukunft der Arbeit (IZA), Bonn (Germany)

    2007-03-15

    Several countries are considering extending Daylight Saving Time (DST) in order to conserve energy, and the U.S. will extend DST by one month beginning in 2007. However, projections that these extensions will reduce electricity consumption rely on extrapolations and simulations rather than empirical evidence. This paper, in contrast, examines a quasiexperiment in which parts of Australia extended DST in 2000 to facilitate the Sydney Olympics. Using detailed panel data and a triple differences specification, we show that the extension did not conserve electricity, and that a prominent simulation model overstates electricity savings when it is applied to Australia. (orig.)

  9. Windows server cookbook for Windows server 2003 and Windows 2000

    CERN Document Server

    Allen, Robbie

    2005-01-01

    This practical reference guide offers hundreds of useful tasks for managing Windows 2000 and Windows Server 2003, Microsoft's latest server. These concise, on-the-job solutions to common problems are certain to save you many hours of time searching through Microsoft documentation. Topics include files, event logs, security, DHCP, DNS, backup/restore, and more

  10. Microsoft Windows Intune 20 Quickstart Administration

    CERN Document Server

    Overton, David

    2012-01-01

    This book is a concise and practical tutorial that shows you how to plan, set up and maintain Windows Intune and manage a group of PCs. If you are an administrator or partner who wants to plan, set up and maintain Windows Intune and manage a group of PCs then this book is for you . You should have a basic understanding of Windows administration, however, knowledge of Windows Intune would not be required.

  11. Does Daylight Saving Save Energy? A Meta-Analysis

    OpenAIRE

    Havránek, Tomáš; Herman, Dominik; Irsova, Zuzana

    2016-01-01

    The original rationale for adopting daylight saving time (DST) was energy savings. Modern research studies, however, question the magnitude and even direction of the effect of DST on energy consumption. Representing the first meta-analysis in this literature, we collect 162 estimates from 44 studies and find that the mean reported estimate indicates modest energy savings: 0.34% during the days when DST applies. The literature is not affected by publication bias, but the results vary systemati...

  12. Byron G. Rogers Federal Building Harvests Daylight and Super Savings

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-01-01

    Case study describes how the Byron G. Rogers Federal Building replaced existing T12 and T8 luminaires with LED dedicated troffers with advanced controls. Together these measures cut lighting energy use by nearly 60% in the 18-story, 791,000-square-foot facility. The new lighting control system provides automated dimming of lights down to 0% output when daylight provides adequate light levels. The project earned GSA an award for exemplary performance from the Interior Lighting Campaign in 2016.

  13. Daylighting in linear atrium buildings at high latitudes

    Energy Technology Data Exchange (ETDEWEB)

    Matusiak, Barbara

    1998-12-31

    This thesis proposes new criteria for visual comfort based on knowledge of visual perception and a method for estimating the modelling ability of light by using inter-reflection calculations. Simplified calculations are presented for the daylight factor in linear building structures, using the projected solid angle principle, for uniform sky and for CIE overcast sky conditions. The calculations are compared with experimental results. Simple diagrams are created based on calculations of the mean daylight factor in rooms adjacent to a narrow street. These diagrams and presented formulas and tables can be used as a simple design tool. Daylighting strategies for linear atrium buildings at high latitudes are developed and examined. These strategies are divided into three groups: (1) the atrium space and facades as light conductor/reflector, (2) the glass roof as a light conductor, and (3) light reflectors on the neighbouring roof. The atrium space and facade strategies are subdivided into passive and active. The strategies connected to the glazed roof includes different configurations of glazing: horizontal, single pitched, double pitched, and the use of laser cut panels and prismatic panels in the glazed roof. The shapes of reflectors on the neighbouring roof are a flat reflector, a parabolic reflector and a parabolic concentrator. Strategies from all three groups are examined on a physical model of scale 1:20 in the artificial sky of mirror box type. Simulations with artificial sun have also been done. The results from model studies are compared with computer simulations. All the active daylighting systems designed for use in the atrium space or on the atrium facades have a huge potential for use in atrium buildings. From the strategies connected with the glazed roof the negatively sloped glass is found to be the best alternative for glazed roofs at high latitudes. Among the roof reflectors, the flat one performs best. 82 refs., 122 figs., 27 tabs.

  14. Holography through optically active windows

    Science.gov (United States)

    Decker, A. J.

    1979-01-01

    By using two orthogonally polarized reference beams, holograms can be recorded through stressed windows and the reconstructed virtual image will show no stress pattern. As shown analytically, the stress-pattern-free hologram is recordable for any polarization state of the object illumination. Hence, the more efficient nondepolarizing diffuser can be used in performing holography through stressed windows if two reference beams are used. Results are presented for a pair of machined polysulfone windows intended for use in a holographic flow-visualization setup in a single-stage-compressor test rig.

  15. Optimal tree design for daylighting in residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Hongbing, Wang [College of Landscape Architecture, Beijing Forestry University, 35, East Qinghua Rd., Beijing (China); Shanghai Botanical Garden, 1111, Longwu Rd., Shanghai (China); Jun, Qin; Yonghong, Hu [Shanghai Botanical Garden, 1111, Longwu Rd., Shanghai (China); Li, Dong [College of Landscape Architecture, Beijing Forestry University, 35, East Qinghua Rd., Beijing (China)

    2010-12-15

    Urban reforestation is advocated as an efficient countermeasure to the intensification of urban heat islands. The greening and beautification of residential quarters is one of the main concerns of residents, while lighting and ventilation are two main energy-consuming building services. Hence, the tree layout in green space between buildings is important, and it is necessary to determine the relationships between trees and buildings. This study takes Shanghai as a case study to optimize tree design between residential buildings and meet good daylighting requirements. Models were made using software such as AutoCAD and SketchUp. The relationships between maximum tree height and building separation were determined. For the same building layout, there were different tree height limits according to crown shape; the order of decreasing height limits was cylindrical, conical, spherical, and inverted conical crowns. Three cases having different green space between building layouts were studied. Their maximum tree heights differed. Overall, our model helps us realize good daylighting of a building environment. The formula allows us to determine which trees to plant between buildings in that we can predict the effects of future tree growth on building daylighting. (author)

  16. Design Guidance for New Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  17. Selection Process for New Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  18. Selection Process for Replacement Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  19. Design Guidance for Replacement Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  20. Replacement Windows for Existing Homes Homes | Efficient Windows

    Science.gov (United States)

    Collaborative Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring

  1. Proper Installation of New Windows | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  2. Provide Views | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  3. Reduced Fading | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  4. EWC Members | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  5. Visible Transmittance | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  6. Gas Fills | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  7. EWC Membership | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  8. Reducing Condensation | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  9. Improved Comfort | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  10. Financing & Incentives | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  11. Tools & Resources | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  12. Books & Publications | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  13. Design Considerations | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  14. Modified optical fiber daylighting system with sunlight transportation in free space.

    Science.gov (United States)

    Vu, Ngoc-Hai; Pham, Thanh-Tuan; Shin, Seoyong

    2016-12-26

    We present the design, optical simulation, and experiment of a modified optical fiber daylighting system (M-OFDS) for indoor lighting. The M-OFDS is comprised of three sub-systems: concentration, collimation, and distribution. The concentration part is formed by coupling a Fresnel lens with a large-core plastic optical fiber. The sunlight collected by the concentration sub-system is propagated in a plastic optical fiber and then collimated by the collimator, which is a combination of a parabolic mirror and a convex lens. The collimated beam of sunlight travels in free space and is guided to the interior by directing flat mirrors, where it is diffused uniformly by a distributor. All parameters of the system are calculated theoretically. Based on the designed system, our simulation results demonstrated a maximum optical efficiency of 71%. The simulation results also showed that sunlight could be delivered to the illumination destination at distance of 30 m. A prototype of the M-OFDS was fabricated, and preliminary experiments were performed outdoors. The simulation results and experimental results confirmed that the M-OFDS was designed effectively. A large-scale system constructed by several M-OFDSs is also proposed. The results showed that the presented optical fiber daylighting system is a strong candidate for an inexpensive and highly efficient application of solar energy in buildings.

  15. Energy Savings by Using Daylight for Basic Urban Shapes : With a Case Study of Three Different Street Types

    OpenAIRE

    Sundborg, Bengt

    2016-01-01

    During winter the sun is in short supply. But research at KTH shows that solar radiation can be facilitated while energy consumption for lighting is reduced. This provided that the buildings are appropriately designed. But, unfortunately, the sunlight is often not taken into account and the results are the opposite. The energy savings depend on good town planning where the daylight is accessible for longer periods of time during the day, both indoors and outdoors. Then, the periods of use for...

  16. Windows and doors

    Energy Technology Data Exchange (ETDEWEB)

    1988-01-01

    A complete manual is presented on windows and doors for the housing contractor. In order to understand the role of windows and doors in a house's energy performance, an introduction explains the house as a system of components that can have effects on each other. Further chapters explain in detail the parts of a window, window types and RSI values; window servicing and repair; window replacement; parts of a door, door types and RSI values; door service and repair, including weatherstripping; door replacement; and how to ensure quality, service, and customer satisfaction. A glossary of terms is included. 61 figs., 3 tabs.

  17. Windows 10 simplified

    CERN Document Server

    McFedries, Paul

    2015-01-01

    Learn Windows 10 quickly and painlessly with this beginner's guide Windows 10 Simplified is your absolute beginner's guide to the ins and outs of Windows. Fully updated to cover Windows 10, this highly visual guide covers all the new features in addition to the basics, giving you a one-stop resource for complete Windows 10 mastery. Every page features step-by-step screen shots and plain-English instructions that walk you through everything you need to know, no matter how new you are to Windows. You'll master the basics as you learn how to navigate the user interface, work with files, create

  18. Mickey Leland Energy Fellowship Report: Development of Advanced Window Coatings

    Energy Technology Data Exchange (ETDEWEB)

    Bolton, Ladena A.; Alvine, Kyle J.; Schemer-Kohrn, Alan L.

    2014-08-05

    Advanced fenestration technologies for light and thermal management in building applications are of great recent research interest for improvements in energy efficiency. Of these technologies, there is specific interest in advanced window coating technologies that have tailored control over the visible and infrared (IR) scattering into a room for both static and dynamic applications. Recently, PNNL has investigated novel subwavelength nanostructured coatings for both daylighting, and IR thermal management applications. Such coatings rese still in the early stages and additional research is needed in terms of scalable manufacturing. This project investigates aspects of a potential new methodology for low-cost scalable manufacture of said subwavelength coatings.

  19. Method for including detailed evaluation of daylight levels in Be06

    DEFF Research Database (Denmark)

    Petersen, Steffen

    2008-01-01

    Good daylight conditions in office buildings have become an important issue due to new European regulatory demands which include energy consumption for electrical lighting in the building energy frame. Good daylight conditions in offices are thus in increased focus as an energy conserving measure....... In order to evaluate whether a certain design is good daylight design or not building designers must perform detailed evaluation of daylight levels, including the daylight performance of dynamic solar shadings, and include these in the energy performance evaluation. However, the mandatory national...... calculation tool in Denmark (Be06) for evaluating the energy performance of buildings is currently using a simple representation of available daylight in a room and simple assumptions regarding the control of shading devices. In a case example, this is leading to an overestimation of the energy consumption...

  20. Could Daylight Glare Be Defined Mathematically?Results of Testing the DGIN Method in Japan

    Science.gov (United States)

    Nazzal, Ali; Oki, Masato

    Discomfort glare from daylight is a common problem without valid prediction methods so far. A new mathematical DGIN (New Daylight Glare Index) method tries to respond the challenge. This paper reports on experiments carried out in daylit office environment in Japan to test applicability of the method. Slight positive correlation was found between the DGIN and the subjective evaluation. Additionally, a high Ladaptation value together with the small ratio of Lwindow to Ladaptation was obviously experienced sufficient to neutralize the effect of glare discomfort. However, subjective assessments are poor glare indicators and not reliable in testing glare prediction methods. DGIN is a good indicator of daylight glare, and when the DGIN value is analyzed together with the measured illuminance ratios, discomfort glare from daylight can be analyzed in a quantitative manner. The DGIN method could serve architects and lighting designers in testing daylighting systems, and also guide the action of daylight responsive lighting controls.

  1. Using the whole-building design approach to incorporate daylighting into a retail space: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Hayter, S.; Torcellini, P.; Eastment, M.; Judkoff, R.

    2000-06-21

    This paper focuses on implementation of daylighting into the Bighorn Center, a collection of home improvement retail spaces in Silverthorne, Colorado, which were constructed in three phases. Daylighting was an integral part of the design of the Phase 3 building. Energy consultants optimized the daylighting design through detailed modeling using an hourly building energy simulation tool. Energy consultants also used this tool to address the building owner's concerns related to customer comfort and increased product sales.

  2. Schematic Window Methodology Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The aim of this IRAD is to produce a generic launch window analyzer (SWM) that allows for large-scale rapid analysis of a launch window and orbit design trade space....

  3. Practicality and Performance of Daylight Trough in The Tropics: A Case Study

    Directory of Open Access Journals (Sweden)

    Gene-Harn Lim

    2016-01-01

    Full Text Available The field of office daylighting is vital for both energy efficiency practice and occupants’ visual comfort. With the emergence of green building in Malaysia, building designers are exploring avenues for energy efficiency design; one common strategy is daylighting. The majority literature reviews on daylighting are skewed towards temperate or developed countries, where sky luminous condition is different from that of the Tropics. Conventional daylighting system designs redirect daylight from the envelope or atrium openings, such as light shelves. Presumed to be the pioneer daylight trough in the Tropics, this paper presents the simulated and in-situ lighting level measurements prior to occupancy. This case study presents an as-built daylight trough design which is able to daylight the office space as deep as 6 meters sufficiently. It achieves a lighting power density 1.90W/m2 and saves 39.2% of lighting energy over conventional office lighting energy. Discussed further is the practicality of working with such a system, including cost implication, return on investment and contractual challenges in reaching a consensus on the design. The results reinforce that the effectiveness of daylighting design is very dependable on the sun path and obstacles surrounding the office tower. The RADIANCE simulation correlates well to field measurement results. Further investigation into the light trough, its lighting energy savings, users’ interaction, visual comfort, and glare is still ongoing.

  4. Enhanced Photocatalytic Degradation of Methyl Orange Dye under the Daylight Irradiation over CN-TiO₂ Modified with OMS-2.

    Science.gov (United States)

    Hassan, Mohamed Elfatih; Chen, Jing; Liu, Guanglong; Zhu, Duanwei; Cai, Jianbo

    2014-12-12

    In this study, CN-TiO₂ was modified with cryptomelane octahedral molecular sieves (OMS-2) by the sol-gel method based on the self-assembly technique to enhance its photocatalytic activity under the daylight irradiation. The synthesized samples were characterized by X-ray diffraction (XRD), UV-vis spectroscopy, Fourier transform infrared spectroscopy (FT-IR) and porosimeter analysis. The results showed that the addition of OMS-2 in the sol lead to higher Brunauer-Emmett-Teller (BET) surface area, pore volume, porosity of particle after heat treatment and the specific surface area, porosity, crystallite size and pore size distribution could be controlled by adjusting the calcination temperature. Compared to the CN-TiO₂-400 sample, CN-TiO₂/OMS-2-400 exhibited greater red shift in absorption edge of samples in visible region due to the OMS-2 coated. The enhancement of photocatalytic activity of CN-TiO₂/OMS-2 composite photocatalyst was subsequently evaluated for the degradation of the methyl orange dye under the daylight irradiation in water. The results showed that the methyl orange dye degradation rate reach to 37.8% for the CN-TiO₂/OMS-2-400 sample under the daylight irradiation for 5 h, which was higher than that of reference sample. The enhancement in daylight photocatalytic activities of the CN-TiO₂/OMS samples could be attributed to the synergistic effects of OMS-2 coated, larger surface area and red shift in adsorption edge of the prepared sample.

  5. Glazing for intelligent daylight utilisation; Verglasungen fuer die intelligente Tageslichtnutzung

    Energy Technology Data Exchange (ETDEWEB)

    Rubbert, F. [VEGLA Vereinigte Glaswerke GmbH, Aachen (Germany)

    1999-10-01

    Daylight, a part of the solar energy incident on the Earth`s surface, is available to us for free and usually in sufficient quantity. Nevertheless, in office and administration buildings artificial lighting is used for an average 60% of total occupancy time. This figure refers not only those times of the year and day when daylight intensity is naturally weak but also includes periods when sunlight is available in excess. To minimise buildings` absorption of solar energy (and so reduce the cooling load) and shield workplaces against direct sunlight, frequent use is made of mechanical shading systems which necessitate the use of artificial lighting, this in turn adding to the cooling load. Several daylight systems have been developed and are now increasingly being used to resolve this paradoxical situation. [Deutsch] Tageslicht, als Bestandteil der Sonnenenergie, steht uns taeglich kostenlos und meistens in ausreichender Menge zur Verfuegung. Dennoch wird in Buero- und Verwaltungsgebaeuden die kuenstliche Beleuchtung im Durchschnitt waehrend etwa 60% der Nutzungszeit eingeschaltet. Dies jedoch nicht nur waehrend der tages- und jahreszeitlich bedingten Phasen mit einer geringen natuerlichen aeusseren Beleuchtungsstaerke, sondern gerade auch zu den Zeiten in denen Sonnenlicht im Uebermass zur Verfuegung steht. Denn zur Minimierung der in die Gebaeude eingebrachten solaren Energie (Reduzierung der Kuehllasten) und zur Erzielung eines Blendschutzes an den betroffenen Arbeitsplaetzen werden sehr haeufig mechanische Verschattungssysteme benutzt, die ein Zuschalten der kuenstlichen Beleuchtung erforderlich machen und somit wieder zu einer Erhoehung der Kuehllasten fuehren. Um dieser Parodoxie aufzuloesen, wurden einige Tageslichtsysteme entwickelt, die im zunehmenden Masse auch praktisch angewandt werden. (orig.)

  6. Roof windows in low-energy buildings - Analyses of demands and possibilities for future product development

    DEFF Research Database (Denmark)

    Skarning, Gunnlaug Cecilie Jensen; Duer, Karsten; Hviid, Christian Anker

    As part of an ambitious energy policy and strategy for reducing the use of fossil fuels in the European Union, all new buildings are required to consume `nearly zero-energy' by the end of 2020. This creates a strong need for research in cost-effective solutions and technology that can help balance...... transmittances of about 40-70% could provide suffcient daylighting without overheating in the climates of Rome and Copenhagen, as long as they were located in rooms with a reasonable layout for daylighting and appropriate solar-control coating was used on solar exposed glazing. The same was true for sloped...... and horizontal roof windows with any choice of light transmittance in both climates. Roof-window thermal properties needed for flexibility were then identied by studying the effect of these options on space-heating demand in rooms representing various parts of a 11/2-storey house with a simplied floor plan and...

  7. Window Selection Tool | Efficient Windows Collaborative

    Science.gov (United States)

    Louisville LA Lake Charles LA New Orleans LA Shreveport MA Boston MD Baltimore ME Portland MI Detroit MI Window Selection Tool will take you through a series of design conditions pertaining to your design and

  8. Windows for Intel Macs

    CERN Document Server

    Ogasawara, Todd

    2008-01-01

    Even the most devoted Mac OS X user may need to use Windows XP, or may just be curious about XP and its applications. This Short Cut is a concise guide for OS X users who need to quickly get comfortable and become productive with Windows XP basics on their Macs. It covers: Security Networking ApplicationsMac users can easily install and use Windows thanks to Boot Camp and Parallels Desktop for Mac. Boot Camp lets an Intel-based Mac install and boot Windows XP on its own hard drive partition. Parallels Desktop for Mac uses virtualization technology to run Windows XP (or other operating systems

  9. Windows® Internals

    CERN Document Server

    Russinovich, Mark E; Ionescu, Alex

    2009-01-01

    See how the core components of the Windows operating system work behind the scenes-guided by a team of internationally renowned internals experts. Fully updated for Windows Server 2008 and Windows Vista, this classic guide delivers key architectural insights on system design, debugging, performance, and support-along with hands-on experiments to experience Windows internal behavior firsthand.Delve inside Windows architecture and internals:Understand how the core system and management mechanisms work-from the object manager to services to the registryExplore internal system data structures usin

  10. A spatially augmented reality sketching interface for architectural daylighting design.

    Science.gov (United States)

    Sheng, Yu; Yapo, Theodore C; Young, Christopher; Cutler, Barbara

    2011-01-01

    We present an application of interactive global illumination and spatially augmented reality to architectural daylight modeling that allows designers to explore alternative designs and new technologies for improving the sustainability of their buildings. Images of a model in the real world, captured by a camera above the scene, are processed to construct a virtual 3D model. To achieve interactive rendering rates, we use a hybrid rendering technique, leveraging radiosity to simulate the interreflectance between diffuse patches and shadow volumes to generate per-pixel direct illumination. The rendered images are then projected on the real model by four calibrated projectors to help users study the daylighting illumination. The virtual heliodon is a physical design environment in which multiple designers, a designer and a client, or a teacher and students can gather to experience animated visualizations of the natural illumination within a proposed design by controlling the time of day, season, and climate. Furthermore, participants may interactively redesign the geometry and materials of the space by manipulating physical design elements and see the updated lighting simulation. © 2011 IEEE Published by the IEEE Computer Society

  11. Multiobjective generalized extremal optimization algorithm for simulation of daylight illuminants

    Science.gov (United States)

    Kumar, Srividya Ravindra; Kurian, Ciji Pearl; Gomes-Borges, Marcos Eduardo

    2017-10-01

    Daylight illuminants are widely used as references for color quality testing and optical vision testing applications. Presently used daylight simulators make use of fluorescent bulbs that are not tunable and occupy more space inside the quality testing chambers. By designing a spectrally tunable LED light source with an optimal number of LEDs, cost, space, and energy can be saved. This paper describes an application of the generalized extremal optimization (GEO) algorithm for selection of the appropriate quantity and quality of LEDs that compose the light source. The multiobjective approach of this algorithm tries to get the best spectral simulation with minimum fitness error toward the target spectrum, correlated color temperature (CCT) the same as the target spectrum, high color rendering index (CRI), and luminous flux as required for testing applications. GEO is a global search algorithm based on phenomena of natural evolution and is especially designed to be used in complex optimization problems. Several simulations have been conducted to validate the performance of the algorithm. The methodology applied to model the LEDs, together with the theoretical basis for CCT and CRI calculation, is presented in this paper. A comparative result analysis of M-GEO evolutionary algorithm with the Levenberg-Marquardt conventional deterministic algorithm is also presented.

  12. Materials And Devices In Electrochromic Window Development

    Science.gov (United States)

    Cogan, Stuart F.; Anderson, Elizabeth J.; Plante, Timothy D.; Rauh, R. David

    1985-12-01

    Windows with switchable electrochromic glazings are potentially useful for regulating solar input to building interiors. In this article, we describe the structure and operation of a proposed solid-state electrochromic glazing based on crystalline LixWO3 (c-LiXWO3) and a low coloration efficiency counter electrode material such as amorphous Nb2O5 (a-Nb2O5). The importance of reversibility in electrochromic glazing operation is emphasized, and optical switching experiments that demonstrate reversible lithium insertion/extraction in c-LixW03, a-LixWO3, and a-LixNb2O5 are described. Additional optical switching experiments in tandem electrochromic cells comprised of c-LixWO3/a-Nb2O5 and a-LixWO3/a-Nb2O5 demonstrated the proposed design, indicating reversible optical switching over 500 and 200 complete cycles, respectively, without degradation. Optical data on the evolution of reflective and absorp-tive modulation in c-LixWO3 are presented and solar attenuation results are used to demon-strate the advantage of using crystalline electrochromics to conserve daylighting during electrochromic window operation.

  13. Daylight-mediated photodynamic therapy of moderate to thick actinic keratoses of the face and scalp

    DEFF Research Database (Denmark)

    Wiegell, S.R.; Fabricius, S.; Philipsen, P.A.

    2012-01-01

    response rate and light dose in patients who received an effective light dose of > 3·5 J cm . Conclusions: Daylight-mediated PDT of moderate to thick AKs was less effective than daylight-mediated PDT of thin AKs especially in some centres. However, nearly all thicker lesions (grades II and III) were...

  14. Daylight and health: A review of the evidence and consequences for the built environment

    NARCIS (Netherlands)

    M.P.J. Aarts; Joost van Hoof; M.B.C. Aries

    2015-01-01

    Daylight has been associated with multiple health advantages. Some of these claims are associations, hypotheses or beliefs. This review presents an overview of a scientific literature search on the proven effects of daylight exposure on human health. Studies were identified with a search strategy

  15. Study of effect of daylight on Building User's Performance Based on Electroencephalograph Signal

    NARCIS (Netherlands)

    Mangkuto, R.A.; Soelami, F.X.N.; Suprijanto, S.

    2009-01-01

    The use of daylighting in building nowadays has become one alternative to save electric energy consumption, particularly during daytime. Daylight is not only useful for reducing cost from electric light sources, but also give benefits both physiologically and psychologically for building users.

  16. Daylighting Concepts for University Libraries and Their Influences on Users' Satisfaction

    Science.gov (United States)

    Kilic, Didem Kan; Hasirci, Deniz

    2011-01-01

    Daylighting, a controlled architectural tool that influences users' perception and behavior, in university libraries and their influences on users' preference and satisfaction was examined in this study. The effects of daylighting in coordination with visual comfort, on university library users were measured in relation to four environmental…

  17. Modelling window opening behaviour in Danish dwellings

    DEFF Research Database (Denmark)

    Andersen, Rune Vinther; Olesen, Bjarne W.; Toftum, Jørn

    2011-01-01

    In this paper we present and analyse data from two studies of window opening behaviour in residential buildings in Denmark. Based on measurements of indoor environment, weather and window opening behaviour in 15 dwellings, we propose a model that will predict window opening behaviour. The data...... showed that other factors than thermal effects impact the behaviour of the occupants. Some of these factors were included in the model. We present data from repeated questionnaire surveys that show that occupants tend to adjust heating setpoints, adjust clothing and operate windows when feeling thermally...

  18. An Exploration into Integrating Daylight and Artificial Light via an Observational Instrument

    DEFF Research Database (Denmark)

    Petersen, Kjell Yngve; Søndergaard, Karin

    2015-01-01

    An Exploration into Integrating Daylight and Artificial Light via an Observational Instrument Daylight is dynamic and dependent upon weather conditions; unfolding with both subtle and dramatic variations in qualities of light. Through a building’s apertures, daylight creates a connection between...... abstract and blurred phenomena, these diffused luminous reflections rouse us into interactions with the world. In this book we are interested in identifying the qualitative parameters involved in the integration of dynamic artificial lighting and daylight; the latter being already highly dynamic by nature...... that examine how the dynamic artificial lighting in the observational instrument unfolds during the changing of the daylight situations that are generated by the weather outside. This research employs the concept of coupling between interior and exterior, in order to identify a spectrum of design parameters...

  19. Daylight-mediated photodynamic therapy of basal cell carcinomas - an explorative study

    DEFF Research Database (Denmark)

    Wiegell, S R; Skødt, V; Wulf, H C

    2014-01-01

    BACKGROUND: Studies have shown that daylight-photodynamic therapy (PDT) is an effective treatment of actinic keratoses, nearly pain free and more convenient for both the clinics and patients. Treatment of basal cell carcinomas (BCCs) is another main indication for PDT. OBJECTIVES: The aim...... of this open, uncontrolled, prospective explorative study was to evaluate the efficacy of daylight-PDT for BCCs. METHODS: Twenty-one patients with a total of 32 BCCs located in the face, scalp, chest, back and lower leg received one cycle of daylight-methyl aminolevulinate (MAL)-PDT, consisting of two...... treatments 1 week apart. After sunscreen application and lesion preparation, MAL was applied and patients exposed themselves to daylight for 2½ h. Daylight exposure was monitored with a wrist-borne dosimeter. RESULTS: At 3-month follow-up, complete response was seen in 30 lesions (94%) and in 19 patients (90...

  20. Detailed simulations of lighting conditions in office rooms lit by daylight and artificial light

    DEFF Research Database (Denmark)

    Iversen, Anne

    In this thesis the effect on the annual artificial lighting demand is investigated by employing detailed simulations of lighting conditions in office rooms lit by daylight and artificial. The simulations of the artificial lighting demand is accomplished through daylight simulations in Radiance....... The detailed simulations includes studies of the resolution of different weather data sets in climate-based daylight modeling. Furthermore, influence of the electrical lighting demand by simulating with dynamic occupancy patterns is studied. Finally the thesis explores the influence of obstructions in an urban...... canyon on the daylight availability within the buildings, and hence on the energy consumption for artificial lights. The results from the thesis demonstrates that the effect on the outcome of the daylight simulations when simulating with typical weather data files for the location of Copenhagen...

  1. STRATEGI DAYLIGHTING PADA BANGUNAN MULTI-LANTAI DI ATAS DAN DI BAWAH PERMUKAAN TANAH

    Directory of Open Access Journals (Sweden)

    Danny Santoso Mintorogo

    1999-01-01

    Full Text Available One of the common factor for Energy Saving on buildings has dealed a lot with the lightings on building, especially for multi level floors above and below grade. In order for saving energy on lightings, many daylighting strategies on multi floors building are being used and under-developed by many architects. This paper discusses the strategies of the daylighting techniques on multi floors building both above and below grade Abstract in Bahasa Indonesia : Strategi hemat energi sangat erat hubungan dengan faktor penerangan dalam bangunan, lebih-lebih pada bangunan berlantai banyak diatas atau dibawah permukaan tanah. Untuk menghemat pemakaian energi listrik dari penerangan ini, maka strategi-strategi penerangan alami "Daylighting" terus dikembangkan. Tulisan ini bertujuan memaparkan berbagai strategi daylighting pada bangunan yang berlantai banyak yang dibangun diatas maupun dibawah permukaan tanah. Kata kunci : daylighting, energi

  2. Switchable Materials for Smart Windows.

    Science.gov (United States)

    Wang, Yang; Runnerstrom, Evan L; Milliron, Delia J

    2016-06-07

    This article reviews the basic principles of and recent developments in electrochromic, photochromic, and thermochromic materials for applications in smart windows. Compared with current static windows, smart windows can dynamically modulate the transmittance of solar irradiation based on weather conditions and personal preferences, thus simultaneously improving building energy efficiency and indoor human comfort. Although some smart windows are commercially available, their widespread implementation has not yet been realized. Recent advances in nanostructured materials provide new opportunities for next-generation smart window technology owing to their unique structure-property relations. Nanomaterials can provide enhanced coloration efficiency, faster switching kinetics, and longer lifetime. In addition, their compatibility with solution processing enables low-cost and high-throughput fabrication. This review also discusses the importance of dual-band modulation of visible and near-infrared (NIR) light, as nearly 50% of solar energy lies in the NIR region. Some latest results show that solution-processable nanostructured systems can selectively modulate the NIR light without affecting the visible transmittance, thus reducing energy consumption by air conditioning, heating, and artificial lighting.

  3. Windows 8 secrets

    CERN Document Server

    Thurrott, Paul

    2012-01-01

    Tips, tricks, treats, and secrets revealed on Windows 8 Microsoft is introducing a major new release of its Windows operating system, Windows 8, and what better way to learn all its ins and outs than from two internationally recognized Windows experts and Microsoft insiders, authors Paul Thurrott and Rafael Rivera? They cut through the hype to get at useful information you'll not find anywhere else, including what role this new OS plays in a mobile and tablet world. Regardless of your level of knowledge, you'll discover little-known facts about how things work, what's new and different, and h

  4. Mastering Windows 7 Deployment

    CERN Document Server

    Finn, Aidan; van Surksum, Kenneth

    2011-01-01

    Get professional-level instruction on Windows 7 deployment tools Enterprise-level operating system deployment is challenging and requires knowledge of specific tools. It is expected that Windows 7 will be extensively deployed in businesses worldwide. This comprehensive Sybex guide provides thorough coverage of the Microsoft deployment tools that were specifically created for Windows 7, preparing system administrators, MIS professionals, and corporate programmers to tackle the task effectively.Companies worldwide are expected to deploy Windows 7 as their enterprise operating system; system admi

  5. Beginning Windows 8

    CERN Document Server

    Halsey, Mike

    2012-01-01

    Windows 8 has been described by Microsoft as its 'boldest' Windows release ever. Beginning Windows 8 takes you through the new features and helps you get more out of the familiar to reveal the possibilities for this amazing new operating system. You will learn, with non-technical language used throughout, how to get up and running in the new Windows interface, minimize downtime, maximize productivity, and harness the features you never knew existed to take control of your computer and enjoy the peace of mind and excitement that comes with it. From tips and tweaks to easy-to-follow guides and d

  6. Windows 8 tweaks

    CERN Document Server

    Sinchak, Steve

    2013-01-01

    Acres of Windows 8 tweaks from a Microsoft MVP and creator of Tweaks.com! From a Microsoft MVP, who is also the savvy creator of Tweaks.com, comes this ultimate collection of Windows 8 workarounds. Steve Sinchak takes you way beyond default system settings, deep under the hood of Windows 8, down to the hidden gems that let you customize your Windows 8 system like you wouldn't believe. From helping you customize the appearance to setting up home networking, sharing media, and squeezing every ounce of performance out of the OS, this book delivers. Get ready to rock and roll with Wind

  7. What's New in Windows Vista?

    CERN Document Server

    Culp, Brian

    2006-01-01

    Get ready for a quick blast through this significant change to Windows! This guide will give you a quick look at many of the most significant new features in Vista, Microsoft's first revision of Windows in nearly six years. Starting with the changes to the interface, introducing Aero, and showing you some visuals, we then move on to the completely revamped search options. The new task scheduler and printing gadgets, are next with some cool new changes. Probably the most significant changes, however, come in the area of security and this guide takes a look at them from user priveleges, to

  8. A thesis investigating the impact of energy related environmental factors on domestic window design

    Science.gov (United States)

    McEvoy, Michael Edward

    In recent years the extent of glazing in houses has been tightly controlled by the Building Regulations in order to save energy. In addition guidelines derived from passive solar principles prescribe the distribution of domestic windows between elevations according to their orientation. This thesis studies the impact of these energy-related environmental factors on domestic window design. The first of these investigations determined the degree to which limitations on the area and arrangement of windows are significant in terms of daylighting. The experiments measured the effect that passive solar requirements and detailed aspects of window design have on the quality of daylighting in houses. The volume of background ventilation required for domestic accommodation has recently been increased. As a result, in a well-sealed construction, heat loss due to background ventilation becomes a larger part of the total heat loss and larger air movements become a potential cause of draughts. The ventilation experiment sought to establish the impact of these more onerous requirements on comfort within rooms. The third experiment combines these factors and asks the question: Could windows be actively involved in overcoming some of these difficulties by being used to preheat ventilation air in order to diminish the extent of heat loss and to alleviate the problem of cold draughts? Also by designing the window to reclaim heat from the room might it be possible to offset the window's thermal inadequacy? Through analysis of responses to a questionnaire and the use of optimisation techniques, scenarios were suggested for the future modification of windows in relation to energy and health expectations. The conclusions form a commentary on recent and future revisions to the Building Regulations and determine whether or not the Regulations facilitate the environmental engineering of windows as an active component of a building's whole environmental system.

  9. Oscillatory integration windows in neurons

    Science.gov (United States)

    Gupta, Nitin; Singh, Swikriti Saran; Stopfer, Mark

    2016-01-01

    Oscillatory synchrony among neurons occurs in many species and brain areas, and has been proposed to help neural circuits process information. One hypothesis states that oscillatory input creates cyclic integration windows: specific times in each oscillatory cycle when postsynaptic neurons become especially responsive to inputs. With paired local field potential (LFP) and intracellular recordings and controlled stimulus manipulations we directly test this idea in the locust olfactory system. We find that inputs arriving in Kenyon cells (KCs) sum most effectively in a preferred window of the oscillation cycle. With a computational model, we show that the non-uniform structure of noise in the membrane potential helps mediate this process. Further experiments performed in vivo demonstrate that integration windows can form in the absence of inhibition and at a broad range of oscillation frequencies. Our results reveal how a fundamental coincidence-detection mechanism in a neural circuit functions to decode temporally organized spiking. PMID:27976720

  10. Teach yourself visually Windows 8

    CERN Document Server

    McFedries, Paul

    2012-01-01

    A practical guide for visual learners eager to get started with Windows 8 If you learn more quickly when you can see how things are done, this Visual guide is the easiest way to get up and running on Windows 8. It covers more than 150 essential Windows tasks, using full-color screen shots and step-by-step instructions to show you just what to do. Learn your way around the interface and how to install programs, set up user accounts, play music and other media files, download photos from your digital camera, go online, set up and secure an e-mail account, and much more. The tried-and-true format

  11. Effect of daylight and gamma-radiation on the colour of fabricated textile polymers

    International Nuclear Information System (INIS)

    Wahab, L.A.; Saad, M.M.; Talaat, M.H.

    2003-01-01

    The effects of gamma-irradiation (0-60 mrad) and natural daylight (0-6 months) on the color and other properties of undyed textile polymers (cotton, nylon-6, polyester/cotton blend and wool/polyester blend) were investigated using optical spectroscopy. The change in color was estimated by yellowness index (Y1) and color difference (Delta E) between the irradiated and unirradiated samples. The analysis used for dosimeter is mainly spectrophotometer in the UV and visible spectrum. Systems having a reproducible response are selected. In the case of cotton fabric the change in color and reflection are showing a promise for dosimeter of gamma-radiation. It was concluded that the whiteness (W) of synthetic and blend fabrics decreased much more than that of cotton fabrics

  12. Economic analysis of the daylight-linked lighting control system in office buildings

    Energy Technology Data Exchange (ETDEWEB)

    Yang, In-Ho; Nam, Eun-Ji [Department of Architectural Engineering, College of Engineering, Dongguk University, 26-3, Pil-dong, Chung-gu, Seoul 100-715 (Korea)

    2010-08-15

    The objective of this study is to perform an economic analysis of the daylight-linked automatic on/off lighting control system installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the energy cost was calculated by using the daylight and building energy analysis simulation. When the lighting control was utilized, an economic analysis was performed using a payback period that was calculated by comparing the initial cost of installing the lighting control system with the annual energy cost which was reduced thanks to the application of the lighting control. The results showed that the lighting energy consumption, when the lighting control was applied, was reduced by an average of 30.5% compared with the case that there was not lighting control applied. Also, the result for total energy consumption showed that, when lighting control was applied, this was reduced by 8.5% when the glazing ratio was 100%, 8.2% for 80%, and 7.6% for 60% when compared to non-application. The payback period was analyzed in terms of the number of floors in a building; 10 floors, 20 floors, 30 floors, and 40 floors. Hence, the building with 40 floors and glazing ratio 100% resulted in the shortest payback period of 8.8 years, the building with 10 floors and glazing ratio 60% resulted in the longest period of 12.7 years. In other words, the larger the glazing ratio and the number of building floors are, the shorter the payback period is. (author)

  13. Color Wheel Windows

    Science.gov (United States)

    Leonard, Stephanie

    2012-01-01

    In this article, the author describes a painting and drawing lesson which was inspired by the beautiful circular windows found in cathedrals and churches (also known as "rose windows"). This two-week lesson would reinforce both the concept of symmetry and students' understanding of the color wheel. (Contains 1 online resource.)

  14. Efficient Windows Collaborative

    Energy Technology Data Exchange (ETDEWEB)

    Nils Petermann

    2010-02-28

    The project goals covered both the residential and commercial windows markets and involved a range of audiences such as window manufacturers, builders, homeowners, design professionals, utilities, and public agencies. Essential goals included: (1) Creation of 'Master Toolkits' of information that integrate diverse tools, rating systems, and incentive programs, customized for key audiences such as window manufacturers, design professionals, and utility programs. (2) Delivery of education and outreach programs to multiple audiences through conference presentations, publication of articles for builders and other industry professionals, and targeted dissemination of efficient window curricula to professionals and students. (3) Design and implementation of mechanisms to encourage and track sales of more efficient products through the existing Window Products Database as an incentive for manufacturers to improve products and participate in programs such as NFRC and ENERGY STAR. (4) Development of utility incentive programs to promote more efficient residential and commercial windows. Partnership with regional and local entities on the development of programs and customized information to move the market toward the highest performing products. An overarching project goal was to ensure that different audiences adopt and use the developed information, design and promotion tools and thus increase the market penetration of energy efficient fenestration products. In particular, a crucial success criterion was to move gas and electric utilities to increase the promotion of energy efficient windows through demand side management programs as an important step toward increasing the market share of energy efficient windows.

  15. Visual merchandising window display

    Directory of Open Access Journals (Sweden)

    Opris (Cas. Stanila M.

    2013-12-01

    Full Text Available Window display plays a major part in the selling strategies; it does not only include the simple display of goods, nowadays it is a form of art, also having the purpose of sustaining the brand image. This article wants to reveal the tools that are essential in creating a fabulous window display. Being a window designer is not an easy job, you have to always think ahead trends, to have a sense of colour, to know how to use light to attract customers in the store after only one glance at the window. The big store window displays are theatre scenes: with expensive backgrounds, special effects and high fashion mannequins. The final role of the displays is to convince customers to enter the store and trigger the purchasing act which is the final goal of the retail activity.

  16. Seasonality in trauma admissions - Are daylight and weather variables better predictors than general cyclic effects?

    Science.gov (United States)

    Røislien, Jo; Søvik, Signe; Eken, Torsten

    2018-01-01

    Trauma is a leading global cause of death, and predicting the burden of trauma admissions is vital for good planning of trauma care. Seasonality in trauma admissions has been found in several studies. Seasonal fluctuations in daylight hours, temperature and weather affect social and cultural practices but also individual neuroendocrine rhythms that may ultimately modify behaviour and potentially predispose to trauma. The aim of the present study was to explore to what extent the observed seasonality in daily trauma admissions could be explained by changes in daylight and weather variables throughout the year. Retrospective registry study on trauma admissions in the 10-year period 2001-2010 at Oslo University Hospital, Ullevål, Norway, where the amount of daylight varies from less than 6 hours to almost 19 hours per day throughout the year. Daily number of admissions was analysed by fitting non-linear Poisson time series regression models, simultaneously adjusting for several layers of temporal patterns, including a non-linear long-term trend and both seasonal and weekly cyclic effects. Five daylight and weather variables were explored, including hours of daylight and amount of precipitation. Models were compared using Akaike's Information Criterion (AIC). A regression model including daylight and weather variables significantly outperformed a traditional seasonality model in terms of AIC. A cyclic week effect was significant in all models. Daylight and weather variables are better predictors of seasonality in daily trauma admissions than mere information on day-of-year.

  17. Seasonality in trauma admissions – Are daylight and weather variables better predictors than general cyclic effects?

    Science.gov (United States)

    Søvik, Signe; Eken, Torsten

    2018-01-01

    Background Trauma is a leading global cause of death, and predicting the burden of trauma admissions is vital for good planning of trauma care. Seasonality in trauma admissions has been found in several studies. Seasonal fluctuations in daylight hours, temperature and weather affect social and cultural practices but also individual neuroendocrine rhythms that may ultimately modify behaviour and potentially predispose to trauma. The aim of the present study was to explore to what extent the observed seasonality in daily trauma admissions could be explained by changes in daylight and weather variables throughout the year. Methods Retrospective registry study on trauma admissions in the 10-year period 2001–2010 at Oslo University Hospital, Ullevål, Norway, where the amount of daylight varies from less than 6 hours to almost 19 hours per day throughout the year. Daily number of admissions was analysed by fitting non-linear Poisson time series regression models, simultaneously adjusting for several layers of temporal patterns, including a non-linear long-term trend and both seasonal and weekly cyclic effects. Five daylight and weather variables were explored, including hours of daylight and amount of precipitation. Models were compared using Akaike’s Information Criterion (AIC). Results A regression model including daylight and weather variables significantly outperformed a traditional seasonality model in terms of AIC. A cyclic week effect was significant in all models. Conclusion Daylight and weather variables are better predictors of seasonality in daily trauma admissions than mere information on day-of-year. PMID:29425210

  18. Alternatives to Outdoor Daylight Illumination for Photodynamic Therapy—Use of Greenhouses and Artificial Light Sources

    Directory of Open Access Journals (Sweden)

    Catharina M. Lerche

    2016-02-01

    Full Text Available Daylight-mediated photodynamic therapy (daylight PDT is a simple and pain free treatment of actinic keratoses. Weather conditions may not always allow daylight PDT outdoors. We compared the spectrum of five different lamp candidates for indoor “daylight PDT” and investigated their ability to photobleach protoporphyrin IX (PpIX. Furthermore, we measured the amount of PpIX activating daylight available in a glass greenhouse, which can be an alternative when it is uncomfortable for patients to be outdoors. The lamps investigated were: halogen lamps (overhead and slide projector, white light-emitting diode (LED lamp, red LED panel and lamps used for conventional PDT. Four of the five light sources were able to photobleach PpIX completely. For halogen light and the red LED lamp, 5000 lux could photobleach PpIX whereas 12,000 lux were needed for the white LED lamp. Furthermore, the greenhouse was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation (UVB radiation passes through the greenhouse glass, so sun protection is not needed.

  19. Alternatives to Outdoor Daylight Illumination for Photodynamic Therapy—Use of Greenhouses and Artificial Light Sources

    DEFF Research Database (Denmark)

    Lerche, Catharina; Heerfordt, Ida M; Heydenreich, Jakob

    2016-01-01

    to photobleach protoporphyrin IX (PpIX). Furthermore, we measured the amount of PpIX activating daylight available in a glass greenhouse, which can be an alternative when it is uncomfortable for patients to be outdoors. The lamps investigated were: halogen lamps (overhead and slide projector), white light...... was suitable for daylight PDT since the effect of solar light is lowered only by 25%. In conclusion, we found four of the five light sources and the greenhouse usable for indoor daylight PDT. The greenhouse is beneficial when the weather outside is rainy or windy. Only insignificant ultraviolet B radiation...

  20. Performance of a daylight redirecting glass shading system demonstration in an office building

    DEFF Research Database (Denmark)

    Appelfeld, David; Svendsen, Svend; Traberg-Borup, Steen

    2011-01-01

    This paper evaluates the daylighting performance of a prototype external dynamic integrated shading and light redirecting system. The demonstration project was carried out on a building with an open-plan office. The prototype and original façades were placed on the same floor with the same...... orientation and similar surroundings. The existing façade was used as the reference for measurements and simulations. The focus of this research project was to employ available simulation tools for the system performance evaluation. This was accompanied by measurements of the daylight conditions...... in the investigated space. The prototype system improved daylighting conditions compared to the existing shading system....

  1. Fatal alcohol-related traffic crashes increase subsequent to changes to and from daylight savings time.

    Science.gov (United States)

    Hicks, G J; Davis, J W; Hicks, R A

    1998-06-01

    On the hypothesis that sleepiness and alcohol interact to increase the risk of alcohol-related traffic fatalities, the percentages of alcohol-related fatal traffic crashes were assessed for the entire state of New Mexico for the years 1989-1992, for each of the seven days that preceded the changes to and from Daylight Savings Time and for each of the 14 days which followed the changes to and from Daylight Savings Time. Consistent with our hypothesis the percentage of alcohol-related fatal crashes increased significantly during the first seven days after these changes in Daylight Savings Time.

  2. Theoretical and experimental analysis of daylight performance for various shading systems

    Energy Technology Data Exchange (ETDEWEB)

    Tsangrassoulis, A [Group Building Enviromental Studies, Lab. of Meteorology, Dept. of Applied Physics, Univ. of Athens (Greece); Santamouris, M [Group Building Enviromental Studies, Lab. of Meteorology, Dept. of Applied Physics, Univ. of Athens (Greece); Asimakopoulos, D [Group Building Enviromental Studies, Lab. of Meteorology, Dept. of Applied Physics, Univ. of Athens (Greece)

    1997-12-31

    The daylight coefficient approach is used for the theoretical analysis of various shading systems. Once a set of these coefficients has been calculated, it is very easy to calculate illuminance in the interior of a room under various sky luminance distributions. The present paper examines a method based on daylight coefficients to evaluate daylight in the interior of a room. The method is compared with existing radiosity and ray-tracing methods. The examined method is experimentaly validated using measurements obtained in a PASSYS test-cell equipped with shading devices. (orig.)

  3. IEA Task 31. Daylighting Buildings in the 21{sup st} Century

    Energy Technology Data Exchange (ETDEWEB)

    Scartezzini, J.-L.; Morel, N.; Andersen, M.; Lindelhoef, D.

    2006-02-15

    This report for the Swiss Federal Office of Energy (SFOE) takes a look at work being carried out within the framework of the International Energy Agency's Solar Heating and Cooling Programme, Task 31 concerning the daylighting of buildings. Research activities in the task's four subtasks, user perspectives and requirements, integration and optimisation of daylighting systems, daylighting design tools and performance tracking network and design support groups are reported on. Objectives, projects and outcomes of each subtask are presented. Swiss contributions to the work done in these subtasks are reviewed and main achievements due to Swiss contributions are listed. Practical examples are quoted.

  4. GA microwave window development

    International Nuclear Information System (INIS)

    Moeller, C.P.; Kasugai, A.; Sakamoto, K.; Takahashi, K.

    1994-10-01

    The GA prototype distributed window was tested in a 32 mm diam. waveguide system at a power density suitable for a MW gyrotron, using the JAERI/Toshiba 110 GHz long pulse internal converter gyrotron in the JAERI test stand. The presence of the untilted distributed window had no adverse effect on the gyrotron operation. A pulse length of 10 times the calculated thermal equilibrium time (1/e time) of 30 msec was reached, and the window passed at least 750 pulses greater than 30 msec and 343 pulses greater than 60 msec. Beyond 100 msec, the window calorimetry reached steady state, allowing the window dissipation to be measured in a single pulse. The measured loss of 4.0% agrees both with the estimated loss, on which the stress calculations are based, and with the attenuation measured at low power in the HE 11 mode. After the end of the tests, the window was examined; no evidence of arcing air coating was found in the part of the window directly illuminated by the microwaves, although there was discoloration in a recess containing an optical diagnostic which outgassed, causing a local discharge to occur in that recess. Finally, there was no failure of the metal-sapphire joints during a total operating time of 50 seconds consisting of pulses longer than 30 msec

  5. Windows 8 simplified

    CERN Document Server

    McFedries, Paul

    2012-01-01

    The easiest way for visual learners to get started with Windows 8 The popular Simplified series makes visual learning easier than ever, and with more than 360,000 copies sold, previous Windows editions are among the bestselling Visual books. This guide goes straight to the point with easy-to-follow, two-page tutorials for each task. With full-color screen shots and step-by-step directions, it gets beginners up and running on the newest version of Windows right away. Learn to work with the new interface and improved Internet Explorer, manage files, share your computer, and much more. Perfect fo

  6. Windows 95 Beslutningsguide

    DEFF Research Database (Denmark)

    Sørensen, Jens Otto

    1996-01-01

    Mange virksomheder der bruger pc'er står netop nu over for valget: Skal vi fortsætte med DOS/Windows 3.x som operativsystem, eller skal vi skifte til efterfølgeren Windows 95? Skal vi/kan vi skifte successivt, eller skal det være en "alt eller intet beslutning". Hvornår er det rigtige tidspunkt...... at skifte? Denne artikel vil forsøge at give en baggrundsviden om Windows 95, der kan hjælpe virksomhederne igennem denne beslutningsfase....

  7. The Efficient Windows Collaborative

    Energy Technology Data Exchange (ETDEWEB)

    Petermann, Nils

    2006-03-31

    The Efficient Windows Collaborative (EWC) is a coalition of manufacturers, component suppliers, government agencies, research institutions, and others who partner to expand the market for energy efficient window products. Funded through a cooperative agreement with the U.S. Department of Energy, the EWC provides education, communication and outreach in order to transform the residential window market to 70% energy efficient products by 2005. Implementation of the EWC is managed by the Alliance to Save Energy, with support from the University of Minnesota and Lawrence Berkeley National Laboratory.

  8. Windows 7 resource kit

    CERN Document Server

    Northrup, Tony; Honeycutt, Jerry; Wilson, Ed

    2009-01-01

    In-depth and comprehensive, this RESOURCE KIT delivers the information you need to administer your Windows 7 system. You get authoritative technical guidance from those who know the technology best-Microsoft Most Valuable Professionals (MVPs) and the Windows 7 product team-along with essential scripts and resources. In addition, "Direct from the Source" sidebars offer deep insights and troubleshooting tips from the Windows 7 team. Get expert guidance on how to: Use Microsoft Deployment Toolkit best practices and tools. Plan user-state migration and test application compatibility.

  9. A simple tool to evaluate the effect of the urban canyon on daylight level and energy demand in the early stages of building design

    DEFF Research Database (Denmark)

    Petersen, Steffen; Momme, Amalie Jin; Hviid, Christian Anker

    2014-01-01

    Daylight is a restricted resource in urban contexts. Rooms situated in an urban context often have a significant proportion of the sky and the sun blocked out by the urban building mass. The reduced direct daylight potential makes daylight reflected from outdoor surfaces an important daylight sou...... the impact of urban canyon parameters on indoor environment and energy performance....

  10. SAF for Windows

    DEFF Research Database (Denmark)

    Hansen, Timme

    2001-01-01

    SAF for Windows er et computerprogram til parametrisk konstruktion af translationsskaller. Skaloverfladernes tredimensionelle, facetterede form fremkommer ved en kombination af to todimensionelle formbestemmende kurver, som kan vælges og redigeres af brugeren. Programmet kan udfolde de genererede...

  11. Workshop report and proposal for a new IEA Task: Daylight in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Kristensen, P E; Johnsen, K

    1994-04-01

    The IEA workshop on Daylight in Buildings was held in Copenhagen on March 14-16, 1994. At the workshop, presentations were given on key topics as a basis for discussions by the experts participating in the meeting. The presentations and discussions covered a range of technical, architectural and amenity aspects of daylighting in buildings. A great interest in research collaboration on daylight was expressed, and it was agreed that plenty of work still needs to be done, and that the appropriate form of work would be an IEA Task. It was agreed that daylighting systems and control strategies should be evaluated and tested in test rooms, as well as in existing buildings as case studies. Furthermore, the workshop expressed that one of the best ways to realize and present the Task results to practice would be through a few demonstration buildings, build in different countries and under different climatic conditions. (EG)

  12. External perforated Solar Screens for daylighting in residential desert buildings: Identification of minimum perforation percentages

    KAUST Repository

    Sherif, Ahmed; Sabry, Hanan; Rakha, Tarek

    2012-01-01

    and Saudi Arabia, result in the admittance of direct solar radiation, which leads to thermal discomfort and the incidence of undesired glare. One type of shading systems that is used to permit daylight while controlling solar penetration is " Solar Screens

  13. Estimation of luminous efficacy of daylight and illuminance for composite climate

    Energy Technology Data Exchange (ETDEWEB)

    Ahmad, Jamil M.; Tiwari, G.N. [Center for Energy Studies, Indian Institute of Technology, Hauz Khas, New Delhi-16 (India)

    2010-07-01

    This Daylighting is one of the basic components of passive solar building design and its estimation is essential. In India there are a few available data of measured illuminance as in many regions of the world. The Indian climate is generally clear with overcast conditions prevailing through the months of July to September, which provides good potential to daylighting in buildings. Therefore, an analytical model that would encompass the weather conditions of New Delhi was selected. Hourly exterior horizontal and slope daylight availability has been estimated for New Delhi using daylight modeling techniques based on solar radiation data. A model to estimate interior illuminance was investigated and validated using experimental hourly inside illuminance data of an existing skylight integrated vault roof mud house in composite climate of New Delhi. The interior illuminance model was found in good agreement with experimental value of interior illuminance.

  14. Windows Security patch required

    CERN Multimedia

    3004-01-01

    This concerns Windows PCs (XP, 2000, NT) which are NOT centrally managed at CERN for security patches, e.g. home PCs, experiment PCs, portables,... A security hole which can give full privileges on Windows systems needs to be URGENTLY patched. Details of the security hole and hotfix are at: http://cern.ch/it-div/news/hotfix-MS03-026.asp http://www.microsoft.com/technet/security/bulletin/MS03-026.asp

  15. Delineating the conformal window

    DEFF Research Database (Denmark)

    Frandsen, Mads Toudal; Pickup, Thomas; Teper, Michael

    2011-01-01

    We identify and characterise the conformal window in gauge theories relevant for beyond the standard model building, e.g. Technicolour, using the criteria of metric confinement and causal analytic couplings, which are known to be consistent with the phase diagram of supersymmetric QCD from Seiberg...... duality. Using these criteria we find perturbation theory to be consistent throughout the predicted conformal window for several of these gauge theories and we discuss recent lattice results in the light of our findings....

  16. Impact of Extended Daylight Saving Time on National Energy Consumption Report to Congress

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, D. B.; Hadley, S. W.; Chin, S-M.

    2008-10-01

    The Energy Policy Act of 2005 (Pub. L. No. 109-58; EPAct 2005) amended the Uniform Time Act of 1966 (Pub. L. No. 89-387) to increase the portion of the year that is subject to Daylight Saving Time. (15 U.S.C. 260a note) EPAct 2005 extended the duration of Daylight Saving Time in the spring by changing its start date from the first Sunday in April to the second Sunday in March, and in the fall by changing its end date from the last Sunday in October to the first Sunday in November. (15 U.S.C. 260a note) EPAct 2005 also called for the Department of Energy to evaluate the impact of Extended Daylight Saving Time on energy consumption in the United States and to submit a report to Congress. (15 U.S.C. 260a note) This report presents the results of impacts of Extended Daylight Saving Time on the national energy consumption in the United States. The key findings are: (1) The total electricity savings of Extended Daylight Saving Time were about 1.3 Tera Watt-hour (TWh). This corresponds to 0.5 percent per each day of Extended Daylight Saving Time, or 0.03 percent of electricity consumption over the year. In reference, the total 2007 electricity consumption in the United States was 3,900 TWh. (2) In terms of national primary energy consumption, the electricity savings translate to a reduction of 17 Trillion Btu (TBtu) over the spring and fall Extended Daylight Saving Time periods, or roughly 0.02 percent of total U.S. energy consumption during 2007 of 101,000 TBtu. (3) During Extended Daylight Saving Time, electricity savings generally occurred over a three- to five-hour period in the evening with small increases in usage during the early-morning hours. On a daily percentage basis, electricity savings were slightly greater during the March (spring) extension of Extended Daylight Saving Time than the November (fall) extension. On a regional basis, some southern portions of the United States exhibited slightly smaller impacts of Extended Daylight Saving Time on energy savings

  17. Roadmap for improving roof and façade windows in nearly zero-energy houses in Europe

    DEFF Research Database (Denmark)

    Skarning, Gunnlaug Cecilie Jensen; Hviid, Christian Anker; Svendsen, Svend

    2016-01-01

    Windows are central for the development of liveable nearly zero-energy homes and require careful consideration. Various studies have indicated that the effect of windows on energy consumption may change significantly with improved building insulation levels. Current guidelines on windows may...... comfort in nearly zero-energy houses located in the European cities Rome and Copenhagen. The aim was to identify options that can support the easy and robust design of future homes with typical use of roof and façade windows. Hourly daylight levels were calculated in DAYSIM, while space heating demand...... and operative temperatures were calculated in EnergyPlus. The results support previous findings on the limited ability of nearly zero-energy buildings to utilise solar gains. It was found that U-values are becoming increasingly important for the energy performance of windows. The paper sketches the increased...

  18. Daylighting and energy performance of a building for composite climate: An experimental study

    OpenAIRE

    Madhu Sudan; G.N. Tiwari

    2016-01-01

    The present study includes overall energy saving through thermal as well as daylighting for composite climate for the building known as SODHA BERS COMPLEX (SBC) situated at Varanasi, India. The building has been designed including all the passive concepts for thermal comfort as well daylighting to maximize the use of natural lighting for the occupants in day to day activities. This approach can be useful for multi-story building for rural and urban areas for both residential and commercial bu...

  19. Refractive integrated nonimaging solar collectors design and analysis of a novel solar-daylighting-technology

    OpenAIRE

    Pelegrini, Alexandre Vieira

    2009-01-01

    This thesis was submitted for the degree of Doctor of Philosophy and awarded by Brunel University. A novel and original category of low-cost static solar-daylighting-collectors named Keywo solar energy, solar collectors, daylighting systems, nonimaging optics, Refractive Integrated Nonimaging Solar Collectors (RINSC) has been designed and thoroughly tested. The RINSC category is based on nonimaging optics and integrates several optical elements, such as prismatic arrays and light guides, i...

  20. Delight2 Daylighting Analysis in Energy Plus: Integration and Preliminary User Results

    Energy Technology Data Exchange (ETDEWEB)

    Carroll, William L.; Hitchcock, Robert J.

    2005-04-26

    DElight is a simulation engine for daylight and electric lighting system analysis in buildings. DElight calculates interior illuminance levels from daylight, and the subsequent contribution required from electric lighting to meet a desired interior illuminance. DElight has been specifically designed to integrate with building thermal simulation tools. This paper updates the DElight capability set, the status of integration into the simulation tool EnergyPlus, and describes a sample analysis of a simple model from the user perspective.

  1. Windows 7 A quick, hands-on introduction

    CERN Document Server

    Lee, Wei-Meng

    2009-01-01

    This compact book offers the quickest path for Windows users to get started with Microsoft's Windows 7 operating system. You get the essential information you need to upgrade or install the system and configure it to fit your activities, along with a tour of Windows 7's features and built-in applications. Microsoft has learned from the mistakes of Windows Vista, and Windows 7 shows it-this new OS is much faster and more stable. With Windows 7: Up and Running, you'll learn what's new and what's changed from XP and Vista, and get advice on ways to use this system for work, entertainment, inst

  2. Impact of daylight saving time on the Chilean residential consumption

    International Nuclear Information System (INIS)

    Verdejo, Humberto; Becker, Cristhian; Echiburu, Diego; Escudero, William; Fucks, Emiliano

    2016-01-01

    Since 1970 Chile has had a Daylight Saving Time (DST) policy in order to reduce residential electricity consumption in the country. The time change was set for the first time by executive decree in 1970, and since that date it was applied every year without great changes until 2010. Since then, and to date, decrees have been set in order to increase the duration of the DST, arguing that there are reasons associated with energy savings that justify the extension of the measure that has been adopted by the authority in recent years. In the present study the impact of the application of DST in terms of decreased household electricity consumption is analyzed using two complementary methods, one based on a heuristic approach and the other using an econometric model. The results indicate that there is indeed a marginally small reduction in residential electricity consumption, although these results are not homogeneous throughout the country. - Highlights: • The impact of the application of DST is analyzed in Chilean distribution networks. • The results indicate that there is indeed a marginally small reduction in residential electricity consumption. • A total energy reduction is estimated based on the proposed methodology.

  3. Daylight-mediated photodynamic therapy in Spain: advantages and disadvantages.

    Science.gov (United States)

    Pérez-Pérez, L; García-Gavín, J; Gilaberte, Y

    2014-09-01

    Photodynamic therapy (PDT) is an option for the treatment of actinic keratosis, Bowen disease, and certain types of basal cell carcinoma. It is also used to treat various other types of skin condition, including inflammatory and infectious disorders. The main disadvantages of PDT are the time it takes to administer (both for the patient and for health professionals) and the pain associated with treatment. Daylight-mediated PDT has recently been reported to be an alternative to the conventional approach. Several studies have shown it to be similar in efficacy to and better tolerated than classic PDT for the treatment of mild to moderate actinic keratosis. Nevertheless, most of these studies are from northern Europe, and no data have been reported from southern Europe. The present article reviews the main studies published to date, presents the treatment protocol, and summarizes our experience with a group of treated patients. Copyright © 2013 Elsevier España, S.L.U. y AEDV. All rights reserved.

  4. Window selection for dual photopeak window scatter correction in Tc-99m imaging

    International Nuclear Information System (INIS)

    Vries, D.J. de; King, M.A.

    1994-01-01

    The width and placement of the windows for the dual photopeak window (DPW) scatter subtraction method for Tc-99m imaging is investigated in order to obtain a method that is stable on a multihead detector system for single photon emission computed tomography (SPECT) and is capable of providing a good scatter estimate for extended objects. For various window pairs, stability and noise were examined with experiments using a SPECT system, while Monte Carlo simulations were used to predict the accuracy of scatter estimates for a variety of objects and to guide the development of regression relations for various window pairs. The DPW method that resulted from this study was implemented with a symmetric 20% photopeak window composed of a 15% asymmetric photopeak window and a 5% lower window abutted at 7 keV below the peak. A power function regression was used to relate the scatter-to-total ratio to the lower window-to-total ratio at each pixel, from which an estimated scatter image was calculated. DPW demonstrated good stability, achieved by abutting the two windows away from the peak. Performance was assessed and compared with Compton window subtraction (CWS). For simulated extended objects, DPW generally produced a less biased scatter estimate than the commonly used CWS method with k = 0.5. In acquisitions of a clinical SPECT phantom, contrast recovery was comparable for both DPW and CWS; however, DPW showed greater visual contrast in clinical SPECT bone studies

  5. Thin Film & Deposition Systems (Windows)

    Data.gov (United States)

    Federal Laboratory Consortium — Coating Lab: Contains chambers for growing thin film window coatings. Plasma Applications Coating Lab: Contains chambers for growing thin film window coatings. Solar...

  6. Windows 8 app projects XAML and C#

    CERN Document Server

    Vermeir, Nico

    2013-01-01

    Become a leading Windows 8 app developer by using Windows 8 App Projects - XAML and C# Edition to learn techniques, tools, and ideas to create successful, 5-star apps. Windows 8 App Projects - XAML and C# Edition shows you the nuts and bolts of the Windows 8 development ecosystem. Then, through a series of example driven chapters, you'll discover how to leverage the platform's unique features. With each project, you'll be one step closer to building full-featured, responsive, and well designed apps that feel like they're a part of the operating system. Windows 8 App Projects - XAML and C# Edit

  7. Dynamic Lighting Concept in Danish Office Environment with Daylight Contribution

    DEFF Research Database (Denmark)

    Logadóttir, Ásta; Christoffersen, Jens

    positioned ~2 respectively ~4 meters from the window. Both the general lighting and desk lamp could be adjusted in correlated colour temperature (CCT) while the general lighting could also be adjusted in intensity. The study was an extension of previous studies conducted without a desk lamp and with subjects...

  8. High performance sapphire windows

    Science.gov (United States)

    Bates, Stephen C.; Liou, Larry

    1993-02-01

    High-quality, wide-aperture optical access is usually required for the advanced laser diagnostics that can now make a wide variety of non-intrusive measurements of combustion processes. Specially processed and mounted sapphire windows are proposed to provide this optical access to extreme environment. Through surface treatments and proper thermal stress design, single crystal sapphire can be a mechanically equivalent replacement for high strength steel. A prototype sapphire window and mounting system have been developed in a successful NASA SBIR Phase 1 project. A large and reliable increase in sapphire design strength (as much as 10x) has been achieved, and the initial specifications necessary for these gains have been defined. Failure testing of small windows has conclusively demonstrated the increased sapphire strength, indicating that a nearly flawless surface polish is the primary cause of strengthening, while an unusual mounting arrangement also significantly contributes to a larger effective strength. Phase 2 work will complete specification and demonstration of these windows, and will fabricate a set for use at NASA. The enhanced capabilities of these high performance sapphire windows will lead to many diagnostic capabilities not previously possible, as well as new applications for sapphire.

  9. Adaptive Liquid Crystal Windows

    Energy Technology Data Exchange (ETDEWEB)

    Taheri, Bahman; Bodnar, Volodymyr

    2011-12-31

    Energy consumption by private and commercial sectors in the U.S. has steadily grown over the last decade. The uncertainty in future availability of imported oil, on which the energy consumption relies strongly, resulted in a dramatic increase in the cost of energy. About 20% of this consumption are used to heat and cool houses and commercial buildings. To reduce dependence on the foreign oil and cut down emission of greenhouse gases, it is necessary to eliminate losses and reduce total energy consumption by buildings. To achieve this goal it is necessary to redefine the role of the conventional windows. At a minimum, windows should stop being a source for energy loss. Ideally, windows should become a source of energy, providing net gain to reduce energy used to heat and cool homes. It is possible to have a net energy gain from a window if its light transmission can be dynamically altered, ideally electronically without the need of operator assistance, providing optimal control of the solar gain that varies with season and climate in the U.S. In addition, the window must not require power from the building for operation. Resolution of this problem is a societal challenge and of national interest and will have a broad global impact. For this purpose, the year-round, allclimate window solution to provide an electronically variable solar heat gain coefficient (SHGC) with a wide dynamic range is needed. AlphaMicron, Inc. (AMI) developed and manufactured 1ft × 1ft prototype panels for the world’s first auto-adjusting Adaptive Liquid Crystal Windows (ALCWs) that can operate from sunlight without the need for external power source and demonstrate an electronically adjustable SHGC. This novel windows are based on AlphaMicron’s patented e-Tint® technology, a guesthost liquid crystal system implemented on flexible, optically clear plastic films. This technology is suitable both for OEM and aftermarket (retro-fitting) lamination to new and existing windows. Low level of

  10. Daylight artificial light and people in an office environment, overview of visual and biological responses

    NARCIS (Netherlands)

    Begemann, S.H.A.; Beld, van den G.J.; Tenner, A.D.

    1997-01-01

    Abstract Long-term behaviour/response of people has been studied in standard window zone offices during daytime working hours. Regular cell-offices were equipped with experimental lighting systems delivering lighting conditions that are known to influence human physiology. The results show that most

  11. Windows 8.1 bible

    CERN Document Server

    Boyce, Jim; Tidrow, Rob

    2014-01-01

    Windows 8.1 coverage that goes above and beyond all competitors? Serving as an evolutionary update to Windows 8, Windows 8.1 provides critical changes to parts of Windows 8, such as greater customization of the interface and boot operations, return of a 'start button' that reveals apps, greater integration between the two interfaces, and updates to apps. Weighing in at nearly 1000 pages, Windows 8.1 Bible provides deeper Windows insight than any other book on the market. It's valuable for both professionals needing a guide to the nooks and crannies of Windows and regular users wanting a wide

  12. The impact of the daylight saving time on electricity consumption-A case study from Jordan

    International Nuclear Information System (INIS)

    Awad Momani, Mohammad; Yatim, Baharudin; Ali, Mohd Alauddin Mohd

    2009-01-01

    The paper examines the impact of daylight saving time (DST) on electricity consumption in Jordan. Two types of analysis were done: the first analysis examines the impact of DST on the lighting loads based on a survey study made for residential and commercial sectors. The second examines the impact of DST on the over all electricity generation through analyzing the daily load curves (DLCs) before and after the DST onset and removal in 2000 and 2007. The results show that the application of DST during the year 2000 saves the electricity used for illumination by -0.73% but it increases the overall generation at the onset and removal of DST by 0.5% and 1.4% due to increase in the heating and cooling loads. The analysis of DLCs during the year 2007 shows similar effects as in the year 2000 except during the early morning period at the DST onset where DST decreases the demand during this time. The analysis shows that DST decreases the electricity demand at DST onset by 0.2% and increases it at DST removal by 0.3%. A possible decrease in the electricity consumption may take place if the DST is implemented from April to end of August.

  13. Microsoft Windows Security Essentials

    CERN Document Server

    Gibson, Darril

    2011-01-01

    Windows security concepts and technologies for IT beginners IT security can be a complex topic, especially for those new to the field of IT. This full-color book, with a focus on the Microsoft Technology Associate (MTA) program, offers a clear and easy-to-understand approach to Windows security risks and attacks for newcomers to the world of IT. By paring down to just the essentials, beginners gain a solid foundation of security concepts upon which more advanced topics and technologies can be built. This straightforward guide begins each chapter by laying out a list of topics to be discussed,

  14. A randomized, multicentre study of directed daylight exposure times of 11/2 vs. 21/2 h in daylight-mediated photodynamic therapy with methyl aminolaevulinate in patients with multiple thin actinic keratoses of the face and scalp

    DEFF Research Database (Denmark)

    Wiegell, S.R.; Fabricius, S.; Philipsen, P.A.

    2011-01-01

    , time of day or time of year during which the treatment was performed. Treatment was well tolerated, with a mean ± SD maximal pain score of 1·3 ± 1·5. Conclusions: Daylight-mediated MAL-PDT is an effective, convenient and nearly pain-free treatment for patients with multiple thin AKs. Daylight-mediated......, the inconvenience of clinic attendance and discomfort during therapy are significant drawbacks. Daylight-mediated PDT could potentially reduce these and may serve as an alternative to conventional PDT. Objectives: To compare the efficacy of methyl aminolaevulinate (MAL)-PDT with 11/2 vs. 21/2 h of daylight exposure...

  15. Teach yourself visually Windows 8 tablets

    CERN Document Server

    McFedries, Paul

    2012-01-01

    A visual guide to all the features of the new Windows 8 Tablet This must-have resource features visually rich, step-by-step instructions that show you how to get the most enjoyment from your Windows 8 tablet. Learn about the exciting new Metro UI, optimized specifically for touch devices. The most popular and commonly used apps and functions are covered too, along with the basics of syncing with a network, setting up e-mail, watching videos, listening to music, and common productivity tasks. This book provides all the guidance needed to enjoy all the best the new Windows 8 tablets have to offe

  16. Glazing façade modules : daylighting performance simulation for Bragança, Coimbra, Évora and Faro

    OpenAIRE

    Sacht, Helenice Maria; Bragança, L.; Almeida, Manuela Guedes de; Caram, Rosana

    2012-01-01

    The daylighting performance improvement is one better strategy to reduce the artificial lighting consumption in buildings and obviously requires solar radiation from the exterior. Daylighting comes not only from direct sunlight but also from illumination provided by the sky on overcast days. Particular attention must be given to daylighting while designing a building when the aim is to maximize visual comfort or to reduce energy consumption. Visual comfort of glazing façades is a fundamental ...

  17. The research of optical windows used in aircraft sensor systems

    International Nuclear Information System (INIS)

    Zhou Feng; Li Yan; Tang Tian-Jin

    2012-01-01

    The optical windows used in aircrafts protect their imaging sensors from environmental effects. Considering the imaging performance, flat surfaces are traditionally used in the design of optical windows. For aircrafts operating at high speeds, the optical windows should be relatively aerodynamic, but a flat optical window may introduce unacceptably high drag to the airframes. The linear scanning infrared sensors used in aircrafts with, respectively, a flat window, a spherical window and a toric window in front of the aircraft sensors are designed and compared. Simulation results show that the optical design using a toric surface has the integrated advantages of field of regard, aerodynamic drag, narcissus effect, and imaging performance, so the optical window with a toric surface is demonstrated to be suited for this application. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)

  18. Characteristics of Air Flow through Windows

    DEFF Research Database (Denmark)

    Heiselberg, Per; Dam, Henrik; Sørensen, Lars C.

    This paper describes the first results of a series of laboratory investigations that is performed to characterise three different window types. The results show the air flow conditions for different ventilation strategies and temperature differences. For one of the windows values of the discharge...... coefficient are shown for both isothermal and non-isothermal flow conditions and the thermal comfort conditions are evaluated by measurements of velocity and temperature levels in the air flow in the occupied zone.......This paper describes the first results of a series of laboratory investigations that is performed to characterise three different window types. The results show the air flow conditions for different ventilation strategies and temperature differences. For one of the windows values of the discharge...

  19. Influence of daylight on the fate of silver and zinc oxide nanoparticles in natural aquatic environments

    International Nuclear Information System (INIS)

    Odzak, Niksa; Kistler, David; Sigg, Laura

    2017-01-01

    Nanoparticles, such as silver (Ag-NP) and zinc oxide (ZnO-NP), are increasingly used in many consumer products. These nanoparticles (NPs) will likely be exposed to the aquatic environment (rain, river, lake water) and to light (visible and UV) in the products where they are applied, or after those products are discharged. Dissolution of Ag-NP and ZnO-NP is an important process because the dissolved Ag + and Zn 2+ are readily available and toxic for aquatic organisms. The objective of this study was to investigate the role of daylight (UV and visible) for the fate of engineered Ag-NP and ZnO-NPs in different types of natural waters. Ag-NP and ZnO-NP were exposed to rainwater, river Rhine, and lake waters (Greifen, Lucerne, Cristallina, Gruère) under different light conditions (no light, UV 300–400 nm and visible light 400–700 nm) for up to 8 days. Stronger agglomeration of Ag-NP was observed in the waters with higher ionic strength in comparison to those with lower ionic strength. Visible light tended to increase the dissolution of Ag-NP under most natural water conditions in comparison to dark conditions, whereas UV-light led to decreased dissolved Ag + after longer exposure time. These effects illustrate the dynamic interactions of Ag-NP with light, which may lead both to increased oxidation and to increased reduction of Ag + by organic compounds under UV-light. In the case of ZnO-NP, agglomeration occurred at higher ionic strength, but the effects of pH were predominant for dissolution, which occurred up to concentrations close to the solubility limit of ZnO(s) at pH around 8.2 and to nearly complete dissolution of ZnO-NP at lower pH (pH 4.8–6.5), with both visible and UV-light facilitating dissolution. This study thus shows that light conditions play an important role in the dissolution processes of nanoparticles. - Highlights: • Effects of visible and UV-light on dissolution of silver and zinc oxide nanoparticles were examined. • Natural waters

  20. Exploring Shop Window Displays

    Science.gov (United States)

    Christopoulou, Martha

    2011-01-01

    Using visual resources from everyday life in art lessons can enrich students' knowledge about the creation of visual images, artifacts, and sites, and develop their critical understanding about the cultural impact of these images and their effects on people's lives. Through examining an exhibition in the windows of Selfridges department store in…

  1. Highly Insulating Windows with a U-value less than 0.6 W/m2K

    Energy Technology Data Exchange (ETDEWEB)

    Wendell Rhine; Ying Tang; Wenting Dong; Roxana Trifu; Reduane Begag

    2008-11-30

    U.S. households rely primarily on three sources of energy: natural gas, electricity, and fuel oil. In the past several decades, electricity consumption by households has grown dramatically, and a significant portion of electricity used in homes is for lighting. Lighting includes both indoor and outdoor lighting and is found in virtually every household in the United States. In 2001, according to the US Energy Information Administration, lighting accounted for 101 billion kWh (8.8 percent) of U.S. household electricity use. Incandescent lamps, which are commonly found in households, are highly inefficient sources of light because about 90 percent of the energy used is lost as heat. For that reason, lighting has been one focus area to increase the efficiency of household electricity consumption. Windows have several functions, and one of the main functions is to provide a view to the outside. Daylighting is another one of windows main functions and determines the distribution of daylight to a space. Daylighting windows do not need to be transparent, and a translucent daylighting window is sufficient, and often desired, to diffuse the light and make the space more environmentally pleasing. In homes, skylights are one source of daylighting, but skylights are not very energy efficient and are inseparably linked to solar heat gain. In some climates, added solar heat gains from daylighting may be welcome; but in other climates, heat gain must be controlled. More energy efficient skylights and daylighting solutions, in general, are desired and can be designed by insulating them with aerogels. Aerogels are a highly insulating and transparent material in its pure form. The overall objective for this project was to prepare an economical, translucent, fiber-reinforced aerogel insulation material for daylighting applications that is durable for manufacturing purposes. This advanced insulation material will increase the thermal performance of daylighting windows, while

  2. Performance of integrated systems of automated roller shade systems and daylight responsive dimming systems

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byoung-Chul; Choi, An-Seop; Jeong, Jae-Weon [Department of Architectural Engineering, Sejong University, Kunja-Dong, Kwangjin-Gu, Seoul (Korea, Republic of); Lee, Eleanor S. [Building Technologies Department, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2011-03-15

    Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane illuminance according to roller shade height and sky conditions for improvement of the system accuracy. In this study, the performance of the integrated systems with two improved closed-loop proportional control algorithms was compared with that of the current (modified) closed-loop proportional control algorithm. In the results, the average maintenance percentage and the average discrepancies of the target illuminance, as well as the average time under 90% of target illuminance for the integrated systems significantly improved in comparison with the current closed-loop proportional control algorithm for daylight responsive dimming systems as a single system. (author)

  3. Daylight saving time transitions and hospital treatments due to accidents or manic episodes

    Directory of Open Access Journals (Sweden)

    Lönnqvist Jouko

    2008-02-01

    Full Text Available Abstract Background Daylight saving time affects millions of people annually but its impacts are still widely unknown. Sleep deprivation and the change of circadian rhythm can trigger mental illness and cause higher accident rates. Transitions into and out of daylight saving time changes the circadian rhythm and may cause sleep deprivation. Thus it seems plausible that the prevalence of accidents and/or manic episodes may be higher after transition into and out of daylight saving time. The aim of this study was to explore the effects of transitions into and out of daylight saving time on the incidence of accidents and manic episodes in the Finnish population during the years of 1987 to 2003. Methods The nationwide data were derived from the Finnish Hospital Discharge Register. From the register we obtained the information about the hospital-treated accidents and manic episodes during two weeks before and two weeks after the transitions in 1987–2003. Results The results were negative, as the transitions into or out of daylight saving time had no significant effect on the incidence of accidents or manic episodes. Conclusion One-hour transitions do not increase the incidence of manic episodes or accidents which require hospital treatment.

  4. Daylight saving time transitions and hospital treatments due to accidents or manic episodes

    Science.gov (United States)

    Lahti, Tuuli A; Haukka, Jari; Lönnqvist, Jouko; Partonen, Timo

    2008-01-01

    Background Daylight saving time affects millions of people annually but its impacts are still widely unknown. Sleep deprivation and the change of circadian rhythm can trigger mental illness and cause higher accident rates. Transitions into and out of daylight saving time changes the circadian rhythm and may cause sleep deprivation. Thus it seems plausible that the prevalence of accidents and/or manic episodes may be higher after transition into and out of daylight saving time. The aim of this study was to explore the effects of transitions into and out of daylight saving time on the incidence of accidents and manic episodes in the Finnish population during the years of 1987 to 2003. Methods The nationwide data were derived from the Finnish Hospital Discharge Register. From the register we obtained the information about the hospital-treated accidents and manic episodes during two weeks before and two weeks after the transitions in 1987–2003. Results The results were negative, as the transitions into or out of daylight saving time had no significant effect on the incidence of accidents or manic episodes. Conclusion One-hour transitions do not increase the incidence of manic episodes or accidents which require hospital treatment. PMID:18302734

  5. Lower HVAC Costs | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  6. Increased Light & View | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  7. Condensation Resistance (CR) | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  8. Fact Sheets & Publications | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  9. State Fact Sheets | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  10. State Code Guides | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  11. Low Conductance Spacers | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  12. National Fenestration Rating Council (NFRC) | Efficient Windows

    Science.gov (United States)

    Collaborative Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring

  13. Energy & Cost Savings | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  14. Provide Natural Light | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  15. Provide Fresh Air | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  16. Air Leakage (AL) | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  17. Evening daylight may cause adolescents to sleep less in spring than in winter

    Science.gov (United States)

    Figueiro, Mariana G.; Rea, Mark S.

    2012-01-01

    Sleep restriction commonly experienced by adolescents can stem from greater sleep pressure by the homeostatic processes and from phase delays of the circadian system. With regard to the latter potential cause, we hypothesized that because there is more natural evening light during the spring than winter, a sample of adolescent students would be more phase delayed in spring than in winter, would have later sleep onset times and, because of fixed school schedules, would have shorter sleep durations. Sixteen eighth-grade subjects were recruited for the study. We collected sleep logs and saliva samples to determine their dim light melatonin onset (DLMO), a well-established circadian marker. Actual circadian light exposures experienced by a subset of twelve subjects over the course of seven days in winter and in spring using a personal, head-worn, circadian light measurement device are also reported here. Results showed that this sample of adolescents was exposed to significantly more circadian light in spring than in winter, especially in the evening hours when light exposure would likely delay circadian phase. Consistent with the light data, DLMO and sleep onset times were significantly more delayed, and sleep durations were significantly shorter in spring than in winter. The present ecological study of light, circadian phase, and self-reported sleep suggests that greater access to evening daylight in the spring may lead to sleep restriction in adolescents while attending school. Therefore, lighting schemes that reduce evening light in the spring may encourage longer sleep times in adolescents. PMID:20653452

  18. Daylight Management in Mediterranean Cities: When Shortage Is Not the Issue

    Directory of Open Access Journals (Sweden)

    Judit Lopez-Besora

    2016-09-01

    Full Text Available Natural resources such as daylight and sunlight are highly appreciated in countries with prevailing overcast skies. Taking advantage of this scarce resource contributes to saving energy on artificial lighting. In contrast to northern, southern European cities are distinguished by a large number of days with direct sunlight caused by a propitious climate condition. While it is a positive issue in terms of energy availability, the abundance of it can be counterproductive if management measures are not taken. Apart from the thermal consequences, lighting penetration into buildings causes a great contrast between inside and outside. This is especially critical when the visual system does not have enough time to adapt, as happens at entrance areas. The aim of this study is to analyze the light contrast between these areas and the urban outside in sunny conditions. To attain this objective, light data from five entrance spaces and their contiguous streets were analyzed and measured. The results were divided into three zones in the visual scene, showing an increasing contrast from top to bottom of the visual field. It may be concluded that interventions applied to urban areas and building pavements can improve visual adaptation in the transition zone.

  19. Thermal bridges of modern windows

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan de Place; Møller, Eva B.; Nielsen, Anker

    2013-01-01

    if the window has an U-factor of 1 W/(m2·K) or lower. This paper describes the development of modern, energy efficient Danish windows with reduced thermal bridges. It focuses on materials, geometry, and sealing of window panes based on a literature review. Examples of modern windows are presented. Experience...... been an important driver for the development of new window solutions in Denmark, increasing the inner-surface temperature at the sealing of window panes. However, it will not stop complaints fromconsumers, as this temperature is calculated under standardized conditions. Increasing requirements...

  20. Daylight Adaptive Shading Using Parametric Camshaft Mechanism for SOHO in Jakarta

    Directory of Open Access Journals (Sweden)

    Sjarifudin Firza Utama

    2014-03-01

    Full Text Available This research analyzes SOHO (Small Office Home Office which can adjust to the need of visual comfort for the users through natural daylighting and also can be adapted to standard requirements of 14 creative industry workspace in Jakartas. The method of the research is by simulating the SOHO unit with variation of shading opening angles in order to adapt to each unit. Analysis done to every shading opening angle to get the appropriate daylight intensity level which support the work activities in every unit for the whole day. In order for the shading to be able to adapt to the changing daylight condition, previously developed parametric camshaft mechanism was used. The study found that the visual comfort for SOHO with creative industries workers in Jakarta can be achieve by varying the shading opening angles between 15-75°.

  1. A Study on the Optimal Duration of Daylight Saving Time (DST in Korea

    Directory of Open Access Journals (Sweden)

    Byeong-Hee Mihn

    2009-09-01

    Full Text Available Daylight saving time aims at spending effective daylight in summer season. Korea had enforced daylight saving time twelve times from 1948 to 1988. Since 1988, it is not executed, but it is recently discussed the resumption of DST. In this paper, we investigate the trend of DST in other countries, review the history of DST in Korea, and suggest the optimal DST duration in terms of astronomical aspects (times of sunrise and sunset. We find that the starting day of DST in Korea is apt for the second Sunday in Mayor the second Sunday in April according to the time of sunrise or to the difference between Korean standard meridian and observer`s, respectively. We also discuss time friction that might be caused by time difference between DST and Korea Standard Time (KST.

  2. Determining daylight and view preferences from the use of blinds in apartments

    DEFF Research Database (Denmark)

    Petersen, Mads Dines

    2015-01-01

    preferences have significant influence on the daylight level and view as well as possible impact on the building’s energy consumption. Therefore, it is important to conduct further studies in the area in order to be able to design solutions that supports the user preferences better and through that improves...... for the inhabitants’ health and well-being, as well as the energy consumption. Present research is an important contribution, because of the increased knowledge about daylights impact on health and well-being as well as daylights impact on the energy consumption in our buildings. However, it is often seen...... that curtains or blinds, often close off new apartment buildings with large glass areas in dense urban context. Such observations indicate that there can be a discrepancy between the intentions of the design team or architect and the perception of the user. The paper presents the results of observations...

  3. Occupants' window opening behaviour

    DEFF Research Database (Denmark)

    Fabi, Valentina; Andersen, Rune Korsholm; Corgnati, Stefano

    2012-01-01

    Energy consumption in buildings is influenced by several factors related to the building properties and the building controls, some of them highly connected to the behaviour of their occupants.In this paper, a definition of items referring to occupant behaviour related to the building control...... systems is proposed, based on studies presented in literature and a general process leading to the effects on energy consumptions is identified.Existing studies on the topic of window opening behaviour are highlighted and a theoretical framework to deal with occupants' interactions with building controls......, aimed at improving or maintaining the preferred indoor environmental conditions, is elaborated. This approach is used to look into the drivers for the actions taken by the occupants (windows opening and closing) and to investigate the existing models in literature of these actions for both residential...

  4. Singapore's Zero-Energy Building's daylight monitoring system

    Energy Technology Data Exchange (ETDEWEB)

    Grobe, Lars; Wittkopf, Stephen; Pandey, Anupama Rana; Xiaoming, Yang; Seng, Ang Kian; Scartezzini, Jean-Louis; Selkowitz, Stephen

    2010-02-28

    A setup to monitor the daylighting performance of different glazing types in Singapore is presented. The glazing is installed in the facade of four dedicated testing chambers in BCAA's Zero Energy Building in Singapore. These test rooms are equipped with sensors that both record illuminances on the work plane, and luminances as seen by occupants. The physical and logical design of the monitoring system is presented. Criteria to assess the daylighting performance are introduced, and initial results of the work in progress are presented.

  5. Estimation Methodology for the Electricity Consumption with the Daylight- and Occupancy-Controlled Artificial Lighting

    DEFF Research Database (Denmark)

    Larsen, Olena Kalyanova; Jensen, Rasmus Lund; Strømberg, Ida Kristine

    2017-01-01

    Artificial lighting represents 15-30% of the total electricity consumption in buildings in Scandinavia. It is possible to avoid a large share of electricity use for lighting by application of daylight control systems for artificial lighting. Existing methodology for estimation of electricity...... consumption with application of such control systems in Norway is based on Norwegian standard NS 3031:2014 and can only provide results from a rough estimate. This paper aims to introduce a new estimation methodology for the electricity usage with the daylight- and occupancy-controlled artificial lighting...

  6. Economic feasibility of maximising daylighting of a standard office building with efficient electric lighting

    DEFF Research Database (Denmark)

    Fontoynont, Marc; Ramananarivo, Karine; Soreze, Thierry Silvio Claude

    2016-01-01

    This paper investigates the cost of developing various daylighting strategies for a standard office building in relation to their ability to reduce electric lighting consumption. The reference building design for this study corresponds to a typical configuration that minimises the construction...... costs and is typical of the French market. We have compared scenarios that entail moving service spaces to the periphery, increasing ceiling height and adding light wells of various shapes. These special features increased the proportion of the indoor area with sufficient daylight by up to 40...

  7. Next generation smart window display using transparent organic display and light blocking screen.

    Science.gov (United States)

    Kim, Gyeong Woo; Lampande, Raju; Choe, Dong Cheol; Ko, Ik Jang; Park, Jin Hwan; Pode, Ramchandra; Kwon, Jang Hyuk

    2018-04-02

    Transparent organic light emitting diodes (TOLED) have widespread applications in the next-generation display devices particularly in the large size transparent window and interactive displays. Herein, we report high performance and stable attractive smart window displays using facile process. Advanced smart window display is realized by integrating the high performance light blocking screen and highly transparent white OLED panel. The full smart window display reveals a maximum transmittance as high as 64.2% at the wavelength of 600 nm and extremely good along with tunable ambient contrast ratio (171.94:1) compared to that of normal TOLED (4.54:1). Furthermore, the performance decisive light blocking screen has demonstrated an excellent optical and electrical characteristics such as i) high transmittance (85.56% at 562nm) at light-penetrating state, ii) superior absorbance (2.30 at 562nm) in light interrupting mode, iii) high optical contrast (85.50 at 562 nm), iv) high optical stability for more than 25,000 cycle of driving, v) fast switching time of 1.9 sec, and vi) low driving voltage of 1.7 V. The experimental results of smart window display are also validated using optical simulation. The proposed smart window display technology allows us to adjust the intensity of daylight entering the system quickly and conveniently.

  8. Application of a spectral sky in Radiance for daylighting calculations including non-image-forming light effects

    NARCIS (Netherlands)

    Khademagha, P.; Aries, M.B.C.; Rosemann, A.L.P.; van Loenen, E.J.

    2016-01-01

    Daylight is dynamic and rich in the blue part of the spectrum. To date, the spectral composition of daylight is ignored in sky models used in Radiance. Spectral sky composition is particularly important when non-image-forming (NIF) light effects are concerned, since the action spectrum for these

  9. Windows in Low Energy Houses. Size Matters

    Energy Technology Data Exchange (ETDEWEB)

    Persson, Mari-Louise

    2004-06-01

    A generally accepted way of building passive houses has been to have small windows facing north and a large glass facade to the south. This is to minimize losses on the north side while gaining as much solar heat as possible on the south. In spring 2001, twenty terraced houses were built outside Goeteborg partly in this way. The indoor temperature is kept at a comfortable level by passive methods, using solar gains and internal gains from household appliances and occupants. Heat losses are very low, since the building envelope is well insulated and since modern coated triple-glazed windows have been installed. The purpose of this work is to investigate how decreasing the window size facing south and increasing the window size facing north in low energy houses will influence the energy consumption and maximum power needed to keep the indoor temperature between 23 and 26 deg C. Different climates and orientations have been investigated and so have the influence of occupancy and window type. A dynamic building simulation tool, DEROB, has been used and the simulations indicate an extremely low energy demand for the houses. The results show that the size of the energy efficient windows does not have a major influence on the heating demand in winter, but is of relevant signification looking at the cooling need in summer. This indicates that instead of the traditional technique of building passive houses it is possible to enlarge the window area facing north and get better lighting conditions. To decrease the energy need for cooling, there is an optimal window size facing south that is smaller than the original size of the investigated buildings.

  10. USB Storage Device Forensics for Windows 10.

    Science.gov (United States)

    Arshad, Ayesha; Iqbal, Waseem; Abbas, Haider

    2018-05-01

    Significantly increased use of USB devices due to their user-friendliness and large storage capacities poses various threats for many users/companies in terms of data theft that becomes easier due to their efficient mobility. Investigations for such data theft activities would require gathering critical digital information capable of recovering digital forensics artifacts like date, time, and device information. This research gathers three sets of registry and logs data: first, before insertion; second, during insertion; and the third, after removal of a USB device. These sets are analyzed to gather evidentiary information from Registry and Windows Event log that helps in tracking a USB device. This research furthers the prior research on earlier versions of Microsoft Windows and compares it with latest Windows 10 system. Comparison of Windows 8 and Windows 10 does not show much difference except for new subkey under USB Key in registry. However, comparison of Windows 7 with latest version indicates significant variances. © 2017 American Academy of Forensic Sciences.

  11. Windows Home Server users guide

    CERN Document Server

    Edney, Andrew

    2008-01-01

    Windows Home Server brings the idea of centralized storage, backup and computer management out of the enterprise and into the home. Windows Home Server is built for people with multiple computers at home and helps to synchronize them, keep them updated, stream media between them, and back them up centrally. Built on a similar foundation as the Microsoft server operating products, it's essentially Small Business Server for the home.This book details how to install, configure, and use Windows Home Server and explains how to connect to and manage different clients such as Windows XP, Windows Vist

  12. Teach yourself visually Windows 10

    CERN Document Server

    McFedries, Paul

    2015-01-01

    Learn Windows 10 visually with step-by-step instructions Teach Yourself VISUALLY Windows 10 is the visual learner's guide to the latest Windows upgrade. Completely updated to cover all the latest features, this book walks you step-by-step through over 150 essential Windows tasks. Using full color screen shots and clear instruction, you'll learn your way around the interface, set up user accounts, play media files, download photos from your camera, go online, set up email, and much more. You'll even learn how to customize Windows 10 to suit the way you work best, troubleshoot and repair common

  13. Windows Terminal Servers Orchestration

    Science.gov (United States)

    Bukowiec, Sebastian; Gaspar, Ricardo; Smith, Tim

    2017-10-01

    Windows Terminal Servers provide application gateways for various parts of the CERN accelerator complex, used by hundreds of CERN users every day. The combination of new tools such as Puppet, HAProxy and Microsoft System Center suite enable automation of provisioning workflows to provide a terminal server infrastructure that can scale up and down in an automated manner. The orchestration does not only reduce the time and effort necessary to deploy new instances, but also facilitates operations such as patching, analysis and recreation of compromised nodes as well as catering for workload peaks.

  14. Invariant sets for Windows

    CERN Document Server

    Morozov, Albert D; Dragunov, Timothy N; Malysheva, Olga V

    1999-01-01

    This book deals with the visualization and exploration of invariant sets (fractals, strange attractors, resonance structures, patterns etc.) for various kinds of nonlinear dynamical systems. The authors have created a special Windows 95 application called WInSet, which allows one to visualize the invariant sets. A WInSet installation disk is enclosed with the book.The book consists of two parts. Part I contains a description of WInSet and a list of the built-in invariant sets which can be plotted using the program. This part is intended for a wide audience with interests ranging from dynamical

  15. Windows Azure Platform

    CERN Document Server

    Redkar, Tejaswi

    2011-01-01

    The Windows Azure Platform has rapidly established itself as one of the most sophisticated cloud computing platforms available. With Microsoft working to continually update their product and keep it at the cutting edge, the future looks bright - if you have the skills to harness it. In particular, new features such as remote desktop access, dynamic content caching and secure content delivery using SSL make the latest version of Azure a more powerful solution than ever before. It's widely agreed that cloud computing has produced a paradigm shift in traditional architectural concepts by providin

  16. Windows Azure web sites

    CERN Document Server

    Chambers, James

    2013-01-01

    A no-nonsense guide to maintaining websites in Windows Azure If you're looking for a straightforward, practical guide to get Azure websites up and running, then this is the book for you. This to-the-point guide provides you with the tools you need to move and maintain a website in the cloud. You'll discover the features that most affect developers and learn how they can be leveraged to work to your advantage. Accompanying projects enhance your learning experience and help you to walk away with a thorough understanding of Azure's supported technologies, site deployment, and manageme

  17. Gabor windows supported on [-1,1] and compactly supported dual windows

    DEFF Research Database (Denmark)

    Christensen, Ole; Kim, H. O.; Rae Young, Kim

    2010-01-01

    window. More precisely, we show that if b window supported on [-N, N]. Under the additional assumption that g is continuous and only has a finite number of zeros on inverted left perpendicular-1, 1inverted right perpendicular, we...... characterize the frame property of {E(mb)T(n)g}(m,n is an element of Z). As a consequence we obtain easily verifiable criteria for a function g to generate a Gabor frame with a dual window having compact support of prescribed size....

  18. Handbook on Windows and Energy

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Schultz, Jørgen Munthe; Svendsen, Sv Aa Højgaard

    The handbook on windows and energy is a general description of windows with the main focus put on the energy performance. Common window products are described by commonly used nomenclature, description of frame and sash conctructions and description of commonly used glazing types.The energy...... transmission through windows is described in detail including radiation, convection and conduction as well as solar transmittance of window glazing. The most used terms related to characterization of window energy performance are defined and calculation methods according to international standards...... flow and detailed calculation of light and solar transmittance is given.Different measurement techniques for characterization of window heat loss coefficient and total solar energy transmittance is described and references to interantional standards are given.Finally, the handbook includes...

  19. The characterisation of the daylighting properties of special glazings and solar shading devices

    NARCIS (Netherlands)

    Dijk, H.A.L. van; Bakker, L.G.

    1998-01-01

    Within the EU DGXII R&D Programme JOULE a project, called REVIS. started in 1998 and will be completed within 2.5 years, with the objective to develop detailed daylight product information of novel products of glazings and solar shading devices. This involves a test procedure, definition of product

  20. Estimation of exterior vertical daylight for the humid tropic of Kota Kinabalu city in East Malaysia

    Energy Technology Data Exchange (ETDEWEB)

    Djamila, Harimi; Ming, Chu Chi; Kumaresan, Sivakumar [School of Engineering and Information Technology, Universiti Malaysia Sabah, Locked Bag No. 2073, 88999 Kota Kinabalu, Sabah (Malaysia)

    2011-01-15

    In tropical regions natural daylight has been a fundamental factor in building design. It is the most efficient way of lighting a building in the daytime and has a great potential for energy conservation in buildings. In Malaysia there are a limited available data of measured illuminance which is the case of several regions in the tropics. Using established models it is possible to predict the luminous efficacy and then estimate the monthly mean hourly exterior illuminance. In this study two different models were chosen. The Perez and Du Mortier-Perraudeau-Page-Littlefair models were selected for the prediction of hourly exterior horizontal illuminance for the city of Kota Kinabalu in East Malaysia. Comparison between the two models were made. The vertical hourly illuminance was predicted also using Perez approach. The potentiality of daylight in four orientations was discussed. This study highlights the importance of Sunpath diagram on daylight illuminance during the conceptual design stage. The results in this study is hoped to contribute further insight into the potentiality of daylighting of tropical sky. (author)

  1. PULSE: Integrated Parametric Modeling for a Shading System : From Daylight Optimization to Additive Manufacturing

    NARCIS (Netherlands)

    Teeling, M.V.M.T.; Turrin, M.; de Ruiter, P.; Turrin, Michela; Peters, Brady; O'Brien, William; Stouffs, Rudi; Dogan, Timur

    2017-01-01

    This paper presents a parametric approach to an integrated and performance-oriented design, from the conceptual design phase towards materialization. The novelty occurs in the use of parametric models as a way of integrating multidisciplinary design constraints, from daylight optimization to the

  2. Practical approach to the use of daylight photodynamic therapy with topical methyl aminolevulinate for actinic keratosis

    DEFF Research Database (Denmark)

    Morton, C A; Wulf, H C; Szeimies, R M

    2015-01-01

    INTRODUCTION: Daylight-mediated photodynamic therapy has been shown to be an effective therapy for actinic keratoses (AKs) and a simple and tolerable treatment procedure in three randomized Scandinavian studies and two recent Phase III randomized controlled studies in Australia and Europe...

  3. A review of methods for the evaluation of the energy contribution of daylight in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Attenborough, M; Goodwin, A

    1996-07-01

    A review has been undertaken of energy prediction methods and daylight calculation methods currently in use in the UK. This was based on a literature review and discussions with large engineering practices and academics involved in the areas of daylighting and energy simulation research. The aim of this review was to identify manual methods or computer programs that are capable of determining energy use in non-domestic buildings and of taking into account the energy savings resulting from daylighting. One potential application for these methods is in supporting anticipated energy targets for non-domestic buildings within Building Regulations and other energy labelling schemes. The review has identified a range of methods which are capable of predicting overall energy use while accounting for daylight. These vary in complexity from empirical methods such as ESICHECK and the CIBSE Energy Code through to dynamic energy simulation models such as DOE 2 and ESP. For each of the methods identified a brief assessment has been made of their technical capabilities ease of use and availability. These assessments have been based on discussions with users and program developers. Descriptions of the various methods are given. (Author)

  4. Effect of daylight saving time on lighting energy use: a literature review

    NARCIS (Netherlands)

    Aries, M.B.C.; Newsham, G.R.

    2008-01-01

    The principal reason for introducing (and extending) daylight saving time (DST) was, and still is, projected energy savings, particularly for electric lighting. This paper presents a literature review concerning the effects of DST on energy use. Simple estimates suggest a reduction in national

  5. Change in the Classroom Deportment of Children Following Change From Daylight Saving Time.

    Science.gov (United States)

    Hicks, Robert A.; And Others

    1980-01-01

    The deportment of each student in a third-grade classroom was rated by the teacher before and after the fall change from daylight savings time, to see if this disruption in circadian rhythms alters behavior. The deportment of boys improved significantly while the deportment of girls was significantly disrupted. (Author/SJL)

  6. 75 FR 36089 - Payment System Risk Policy; Daylight Overdraft Posting Rules

    Science.gov (United States)

    2010-06-24

    ... FEDERAL RESERVE SYSTEM [OP-1385] Payment System Risk Policy; Daylight Overdraft Posting Rules... Payment System Risk Policy, the Board is announcing posting rules for a new same-day automated clearing... Kirkpatrick, Senior Financial Services Analyst, Payment System Risk (202-452-2796), or Jennifer Davidson...

  7. 77 FR 22666 - Payment System Risk Policy; Daylight Overdraft Posting Rules

    Science.gov (United States)

    2012-04-17

    ... FEDERAL RESERVE SYSTEM 12 CFR Part 204 [Docket No. OP-1440] Payment System Risk Policy; Daylight.... SUMMARY: The Board of Governors of the Federal Reserve System (Board) has revised its Policy on Payment...), Division of Reserve Bank Operations and Payment Systems. For users of Telecommunications Device for the...

  8. 78 FR 70046 - Payment System Risk Policy; Daylight Overdraft Posting Rules

    Science.gov (United States)

    2013-11-22

    ... FEDERAL RESERVE SYSTEM [Docket No. OP--1471] Payment System Risk Policy; Daylight Overdraft... Reserve Policy on Payment System Risk (PSR policy) to eliminate certain posting rules to conform with... Services Analyst (202- 452-2404), Division of Reserve Bank Operations and Payment Systems. For users of...

  9. Chromatic illumination discrimination ability reveals that human colour constancy is optimised for blue daylight illuminations.

    Directory of Open Access Journals (Sweden)

    Bradley Pearce

    Full Text Available The phenomenon of colour constancy in human visual perception keeps surface colours constant, despite changes in their reflected light due to changing illumination. Although colour constancy has evolved under a constrained subset of illuminations, it is unknown whether its underlying mechanisms, thought to involve multiple components from retina to cortex, are optimised for particular environmental variations. Here we demonstrate a new method for investigating colour constancy using illumination matching in real scenes which, unlike previous methods using surface matching and simulated scenes, allows testing of multiple, real illuminations. We use real scenes consisting of solid familiar or unfamiliar objects against uniform or variegated backgrounds and compare discrimination performance for typical illuminations from the daylight chromaticity locus (approximately blue-yellow and atypical spectra from an orthogonal locus (approximately red-green, at correlated colour temperature 6700 K, all produced in real time by a 10-channel LED illuminator. We find that discrimination of illumination changes is poorer along the daylight locus than the atypical locus, and is poorest particularly for bluer illumination changes, demonstrating conversely that surface colour constancy is best for blue daylight illuminations. Illumination discrimination is also enhanced, and therefore colour constancy diminished, for uniform backgrounds, irrespective of the object type. These results are not explained by statistical properties of the scene signal changes at the retinal level. We conclude that high-level mechanisms of colour constancy are biased for the blue daylight illuminations and variegated backgrounds to which the human visual system has typically been exposed.

  10. Installing and Setting Up Git Software Tool on Windows | High-Performance

    Science.gov (United States)

    Computing | NREL Git Software Tool on Windows Installing and Setting Up Git Software Tool on Windows Learn how to set up the Git software tool on Windows for use with the Peregrine system. Git is this doc, we'll show you how to get git installed on Windows 7, and how to get things set up on NREL's

  11. Windows on the axion

    International Nuclear Information System (INIS)

    Turner, M.S.

    1989-04-01

    Peccei-Quinn symmetry with attendant axion is a most compelling, and perhaps the most minimal, extension of the standard model, as it provides a very elegant solution to the nagging strong CP-problem associated with the Θ vacuum structure of QCD. However, particle physics gives little guidance as to the axion mass; a priori, the plausible values span the range: 10/sup /minus/12/ eV /approx lt/ m/sub a/ /approx lt/ 10 6 eV, some 18 orders-of-magnitude. Axions have a host of interesting astrophysical and cosmological effects, including, modifying the evolution of stars of all types (our sun, red giants, white dwarfs, and neutron stars), contributing significantly to the mass density of the Universe today, and producing detectable line radiation through the decays of relic axions. Consideration of these effects has probed 14 orders-of-magnitude in axion mass, and has left open only two windows for further exploration: 10/sup /minus/6/ eV /approx lt/ m/sub a/ /approx lt/ 10/sup /minus/3/ eV and 1 eV /approx lt/ m/sub a/ /approx lt/ 5 eV (hadronic axions only). Both these windows are accessible to experiment, and a variety of very interesting experiments, all of which involve ''heavenly axions,'' are being planned or are underway. 58 refs., 6 figs., 1 tab

  12. WINDOW-CLEANING

    CERN Multimedia

    Environmental Section / ST-TFM

    2001-01-01

    The two-month window-cleaning session on the Meyrin, Prévessin and LEP sites will soon begin. The cleaning contractors will work from Monday to Saturday, every week from 4.00 a.m. to 8.00 p.m. The work will be organised so as to disturb users as little as possible. In any event, a work notice will be left in each office 24 hours beforehand. To prevent any damage to documents or items which could occur despite the precautions taken, please clear completely the window-sills and the area immediately around them. If, however, for valid reasons, the work cannot be done on the scheduled day, please inform the Environmental Section by telephoning: 73753 / 74233 / 72242 If you are going to be absent during this two-month period, we should be grateful if you would clear the above mentioned areas before your departure. REMINDER To allow more thorough cleaning of the entrance doors to buildings and also facilitate the weekly work of the cleaning contractors, we ask you to make use of the notice boards at the...

  13. Working with Windows 7 at CERN (EN)

    CERN Multimedia

    CERN. Geneva

    2010-01-01

    Overview of new concepts and user interface changes in Windows 7 as compared with older versions of Windows: XP or Vista. Availability of Windows 7 at CERN and its integration with CERN Windows infrastructure will be discussed.

  14. Gabor windows supported on [ − 1, 1] and dual windows with small support

    DEFF Research Database (Denmark)

    Christensen, Ole; Kim, Hong Oh; Kim, Rae Young

    2012-01-01

    Consider a continuous function g ∈ L 2(ℝ) that is supported on [ − 1, 1] and generates a Gabor frame with translation parameter 1 and modulation parameter 0 for some N ∈ ℕ. Under an extra condition on the zeroset of the window g we show that there exists a continuous dual window supported on [ − N...

  15. Tuning the diurnal natural daylight with phosphor converted white LED – Advent of new phosphor blend composition

    International Nuclear Information System (INIS)

    Kim, Yoon Hwa; Arunkumar, Paulraj; Park, Seung Hyok; Yoon, Ho Shin; Im, Won Bin

    2015-01-01

    Highlights: • Designed phosphor blend that mimics diurnal daylight for health benefits. • Developed new phosphor blend composition that mimics natural sunlight under near UV. • The phosphor blend also exhibits high CRI (≥90) under blue LED excitation. • Fabricated WLED exhibited ∼91% spectral resemblance with daylight at 4500 K. • While ∼39.2% spectral resemblance were observed for YAG:Ce 3+ at 4500 K. - Abstract: We demonstrate the feasibility of developing phosphor converted white LED (pc-WLED) that mimics diurnal natural daylight with the newly designed phosphor blend in the color temperature (CCT) 2700–6000 K for health benefits. Natural daylight (sunlight) spectrum possesses broad emission in the visible region and closely approximates black body radiator, with color rendition index (CRI) of 100 under wide CCT (2500–6500 K). Current white light LEDs although are efficient and durable, they are not broad enough compared to daylight. We report new phosphor blend based on Sr 3 MgSi 2 O 8 :Eu 2+ blue phosphor with broad emission and high CRI ≥ 96 under both near UV and blue excitation. The fabricated WLED has exhibited ∼91% spectral resemblance with natural daylight compared to 39.2% for YAG:Ce 3+ white LED at 4500 K. The developed phosphor blend tunes the spectrum in wider CCT and would be a prospective candidate for full spectrum daylight WLED

  16. Tuning the diurnal natural daylight with phosphor converted white LED – Advent of new phosphor blend composition

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yoon Hwa [School of Materials Science and Engineering, Chonnam National University, 300, Yongbong-dong, Buk-gu, Gwangju 500-757 (Korea, Republic of); Research Institute, Force4 Corp., Daechon-dong, Buk-gu, Gwangju 500-470 (Korea, Republic of); Arunkumar, Paulraj [School of Materials Science and Engineering, Chonnam National University, 300, Yongbong-dong, Buk-gu, Gwangju 500-757 (Korea, Republic of); Park, Seung Hyok; Yoon, Ho Shin [Research Institute, Force4 Corp., Daechon-dong, Buk-gu, Gwangju 500-470 (Korea, Republic of); Im, Won Bin, E-mail: imwonbin@jnu.ac.kr [School of Materials Science and Engineering, Chonnam National University, 300, Yongbong-dong, Buk-gu, Gwangju 500-757 (Korea, Republic of)

    2015-03-15

    Highlights: • Designed phosphor blend that mimics diurnal daylight for health benefits. • Developed new phosphor blend composition that mimics natural sunlight under near UV. • The phosphor blend also exhibits high CRI (≥90) under blue LED excitation. • Fabricated WLED exhibited ∼91% spectral resemblance with daylight at 4500 K. • While ∼39.2% spectral resemblance were observed for YAG:Ce{sup 3+} at 4500 K. - Abstract: We demonstrate the feasibility of developing phosphor converted white LED (pc-WLED) that mimics diurnal natural daylight with the newly designed phosphor blend in the color temperature (CCT) 2700–6000 K for health benefits. Natural daylight (sunlight) spectrum possesses broad emission in the visible region and closely approximates black body radiator, with color rendition index (CRI) of 100 under wide CCT (2500–6500 K). Current white light LEDs although are efficient and durable, they are not broad enough compared to daylight. We report new phosphor blend based on Sr{sub 3}MgSi{sub 2}O{sub 8}:Eu{sup 2+} blue phosphor with broad emission and high CRI ≥ 96 under both near UV and blue excitation. The fabricated WLED has exhibited ∼91% spectral resemblance with natural daylight compared to 39.2% for YAG:Ce{sup 3+} white LED at 4500 K. The developed phosphor blend tunes the spectrum in wider CCT and would be a prospective candidate for full spectrum daylight WLED.

  17. Window observers for linear systems

    Directory of Open Access Journals (Sweden)

    Utkin Vadim

    2000-01-01

    Full Text Available Given a linear system x ˙ = A x + B u with output y = C x and a window function ω ( t , i.e., ∀ t , ω ( t ∈ {0,1 }, and assuming that the window function is Lebesgue measurable, we refer to the following observer, x ˆ = A x + B u + ω ( t L C ( x − x ˆ as a window observer. The stability issue is treated in this paper. It is proven that for linear time-invariant systems, the window observer can be stabilized by an appropriate design under a very mild condition on the window functions, albeit for linear time-varying system, some regularity of the window functions is required to achieve observer designs with the asymptotic stability. The corresponding design methods are developed. An example is included to illustrate the possible applications

  18. Bispectral analysis: comparison of two windowing functions

    Science.gov (United States)

    Silvagni, D.; Djerroud, C.; Réveillé, T.; Gravier, E.

    2018-02-01

    Amongst all the normalized forms of bispectrum, the bicoherence is shown to be a very useful diagnostic tool in experimental studies of nonlinear wave interactions in plasma, as it measures the fraction of wave power due to the quadratic wave coupling in a self-excited fluctuation spectrum [1, 2]. In order to avoid spectral leakage, the application of a windowing function is needed during the bicoherence computation. Spectral leakage from statistically dependent components are of crucial importance in the discrimination between coupled and uncoupled modes, as they will introduce in the bicoherence spectrum phase-coupled modes which in reality do not exist. Therefore, the windowing function plays a key role in the bicoherence estimation. In this paper, two windowing methods are compared: the multiplication of the initial signal by the Hanning function and the subtraction of the straight line which links the two extremities of the signal. The influence of these two windowing methods on both the power spectrum and the bicoherence spectrum is showed. Although both methods give precise results, the Hanning function appears to be the more suitable window.

  19. Temperature Profile of IR Blocking Windows Used in Cryogenic X-Ray Spectrometers

    International Nuclear Information System (INIS)

    Friedrich, S.; Funk, T.; Drury, O.; Labov, S.E.

    2000-01-01

    Cryogenic high-resolution X-ray spectrometers are typically operated with thin IR blocking windows to reduce radiative heating of the detector while allowing good x-ray transmission. We have estimated the temperature profile of these IR blocking windows under typical operating conditions. We show that the temperature in the center of the window is raised due to radiation from the higher temperature stages. This can increase the infrared photon flux onto the detector, thereby increasing the IR noise and decreasing the cryostat hold time. The increased window temperature constrains the maximum window size and the number of windows required. We discuss the consequences for IR blocking window design

  20. Windows 7 The Missing Manual

    CERN Document Server

    Pogue, David

    2010-01-01

    In early reviews, geeks raved about Windows 7. But if you're an ordinary mortal, learning what this new system is all about will be challenging. Fear not: David Pogue's Windows 7: The Missing Manual comes to the rescue. Like its predecessors, this book illuminates its subject with reader-friendly insight, plenty of wit, and hardnosed objectivity for beginners as well as veteran PC users. Windows 7 fixes many of Vista's most painful shortcomings. It's speedier, has fewer intrusive and nagging screens, and is more compatible with peripherals. Plus, Windows 7 introduces a slew of new features,

  1. Microsoft Windows Operating System Essentials

    CERN Document Server

    Carpenter, Tom

    2012-01-01

    A full-color guide to key Windows 7 administration concepts and topics Windows 7 is the leading desktop software, yet it can be a difficult concept to grasp, especially for those new to the field of IT. Microsoft Windows Operating System Essentials is an ideal resource for anyone new to computer administration and looking for a career in computers. Delving into areas such as fundamental Windows 7 administration concepts and various desktop OS topics, this full-color book addresses the skills necessary for individuals looking to break into a career in IT. Each chapter begins with a list of topi

  2. Beginning Windows 8.1

    CERN Document Server

    Halsey, Mike

    2013-01-01

    Windows 8 has been described by Microsoft as its 'boldest' Windows release ever and the 8.1 update enhances the paradigm further. Beginning Windows 8.1 takes you through the new features and helps you get more out of the familiar to reveal the fullest possibilities for this amazing new operating system. You will learn, with non-technical language used throughout, how to get up and running in the new Windows interface, minimize downtime, maximize productivity, and harness the features you never knew existed to take control of your computer and enjoy the peace of mind and excitement that comes w

  3. Live histograms in moving windows

    International Nuclear Information System (INIS)

    Zhil'tsov, V.E.

    1989-01-01

    Application of computer graphics for specific hardware testing is discussed. The hardware is position sensitive detector (multiwire proportional chamber) which is used in high energy physics experiments, and real-out electronics for it. Testing program is described (XPERT), which utilises multi-window user interface. Data are represented as histograms in windows. The windows on the screen may be moved, reordered, their sizes may be changed. Histograms may be put to any window, and hardcopy may be made. Some program internals are discussed. The computer environment is quite simple: MS-DOS IBM PC/XT, 256 KB RAM, CGA, 5.25'' FD, Epson MX. 4 refs.; 7 figs

  4. Mastering Microsoft Windows Small Business Server 2008

    CERN Document Server

    Johnson, Steven

    2010-01-01

    A complete, winning approach to the number one small business solution. Do you have 75 or fewer users or devices on your small-business network? Find out how to integrate everything you need for your mini-enterprise with Microsoft's new Windows Server 2008 Small Business Server, a custom collection of server and management technologies designed to help small operations run smoothly without a giant IT department. This comprehensive guide shows you how to master all SBS components as well as handle integration with other Microsoft technologies.: Focuses on Windows Server 2008 Small Business Serv

  5. Teach yourself visually Windows 8.1

    CERN Document Server

    McFedries, Paul

    2013-01-01

    A practical guide for visual learners eager to get started with Windows 8.1 If you learn more quickly when you can see how things are done, this Visual guide is the easiest way to get up and running on Windows 8.1. It covers more than 150 essential Windows tasks, using full-color screen shots and step-by-step instructions to show you just what to do. Learn your way around the interface and how to install programs, set up user accounts, play music and other media files, download photos from your digital camera, go online, set up and secure an e-mail account, and much more.The tried-and-true f

  6. Replicate periodic windows in the parameter space of driven oscillators

    Energy Technology Data Exchange (ETDEWEB)

    Medeiros, E.S., E-mail: esm@if.usp.br [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo (Brazil); Souza, S.L.T. de [Universidade Federal de Sao Joao del-Rei, Campus Alto Paraopeba, Minas Gerais (Brazil); Medrano-T, R.O. [Departamento de Ciencias Exatas e da Terra, Universidade Federal de Sao Paulo, Diadema, Sao Paulo (Brazil); Caldas, I.L. [Instituto de Fisica, Universidade de Sao Paulo, Sao Paulo (Brazil)

    2011-11-15

    Highlights: > We apply a weak harmonic perturbation to control chaos in two driven oscillators. > We find replicate periodic windows in the driven oscillator parameter space. > We find that the periodic window replication is associated with the chaos control. - Abstract: In the bi-dimensional parameter space of driven oscillators, shrimp-shaped periodic windows are immersed in chaotic regions. For two of these oscillators, namely, Duffing and Josephson junction, we show that a weak harmonic perturbation replicates these periodic windows giving rise to parameter regions correspondent to periodic orbits. The new windows are composed of parameters whose periodic orbits have the same periodicity and pattern of stable and unstable periodic orbits already existent for the unperturbed oscillator. Moreover, these unstable periodic orbits are embedded in chaotic attractors in phase space regions where the new stable orbits are identified. Thus, the observed periodic window replication is an effective oscillator control process, once chaotic orbits are replaced by regular ones.

  7. Windows 8.1 for seniors for dummies

    CERN Document Server

    Weverka, Peter

    2013-01-01

    Seniors, here's what you need to get up and running on Windows 8.1 Microsoft, now a little older and wiser, is back with Windows 8.1, the revamped version that brings fresh changes and welcome improvements to the Windows 8 operating system. And now you savvy seniors can get the very most out of this easier-to-use Windows 8.1 with our friendly new guide. Using large print that makes the book easier to read plus magnified screen shots to help make Windows less intimidating, this book walks you through common tasks and show you how to get things done in fine style. Helps you get to know Windows

  8. Postbuckling behavior of windows subjected to synchrotron radiation x-rays

    International Nuclear Information System (INIS)

    Wang, Z.; Kuzay, T.M.; Sharma, S.K.

    1993-01-01

    Analyses performed on two Be windows (250 and 100 μm thick) show that the additional postbuckling strength still exists after initial window buckling and this part can be used by a thin window design in the working stage. However, the load factor to complate failure is not as big as the load factor to failure of a uniformly compressed window (the case for a thick window where buckling stress is larger than yielding stress of the window material). That is, the load factor of a thin window to collapse is not as large as that of a thick window without buckling. Hence, unless there is a special need for a thin window, buckling of the windows in normal working stage should not be recommended. Although shakedown was not considered, a similar conclusion can be expected for that case

  9. Learning Windows Azure Mobile Services for Windows 8 and Windows Phone 8

    CERN Document Server

    Webber-Cross, Geoff

    2014-01-01

    This book is based around a case study game which was written for the book. This means that the chapters progress in a logical way and build upon lessons learned as we go. Real-world examples are provided for each topic that are practical and not given out-of-context so they can be applied directly to other applications.If you are a developer who wishes to build Windows 8 and Phone 8 applications and integrate them with Windows Azure Mobile Services, this book is for you. Basic C# and JavaScript skills are advantageous, as well as some knowledge of building Windows 8 or Windows Phone 8 applica

  10. Rootkit pro MS Windows

    OpenAIRE

    Trutman, Michal

    2012-01-01

    Tato bakalářská práce se zabývá metodami útoků na operační systém MS Windows a přibližuje techniky skrývání výpočetních prostředků používané existujícími rootkity. Práce je rozdělena na teoretickou a praktickou část. První část pojednává o klasifikaci rootkitů, představuje strukturu jádra systému a následně popisuje jednotlivé techniky napadení operačního systému. V praktické části je prezentována implementace a testování vlastního rootkitu. This bachelor's thesis deals with methods of att...

  11. Destiny's Earth Observation Window

    Science.gov (United States)

    2002-01-01

    Astronaut Michael J. Bloomfield, STS-110 mission commander, looks through the Earth observation window in the Destiny laboratory aboard the International Space Station (ISS). The STS-110 mission prepared the ISS for future spacewalks by installing and outfitting the S0 (S-zero) truss and the Mobile Transporter. The 43-foot-long S0 Truss, weighing in at 27,000 pounds, was the first of 9 segments that will make up the Station's external framework that will eventually stretch 356 feet (109 meters), or approximately the length of a football field. This central truss segment also includes a flatcar called the Mobile Transporter and rails that will become the first 'space railroad,' which will allow the Station's robotic arm to travel up and down the finished truss for future assembly and maintenance. The completed truss structure will hold solar arrays and radiators to provide power and cooling for additional international research laboratories from Japan and Europe that will be attached to the Station. Milestones of the STS-110 mission included the first time the ISS robotic arm was used to maneuver spacewalkers around the Station and marked the first time all spacewalks were based out of the Station's Quest Airlock. It was also the first Shuttle to use three Block II Main Engines. The Space Shuttle Orbiter Atlantis, STS-110 mission, was launched April 8, 2002 and returned to Earth April 19, 2002.

  12. Window prototypes during the project

    DEFF Research Database (Denmark)

    Schultz, Jørgen Munthe

    1996-01-01

    The conditions for the PASSYS test and the results of the measurements on one of the aerogel window prototypes are described.......The conditions for the PASSYS test and the results of the measurements on one of the aerogel window prototypes are described....

  13. Computer Modeling of Daylight-Integrated Photocontrol of Electric Lighting Systems

    Directory of Open Access Journals (Sweden)

    Richard Mistrick

    2015-05-01

    Full Text Available This article presents a variety of different approaches to both model and assess the performance of daylight-integrated electric lighting control systems. In these systems, the output of a controlled lighting zone is based on a light sensor reading and a calibrated control algorithm. Computer simulations can consider the simulated illuminance data generated from both the electric lighting system and a daylight delivery system whose performance is addressed using typical meteorological year (TMY weather data. Photosensor signals and the operation of a control system’s dimming algorithms are also included. Methods and metrics for evaluating simulated performance for the purpose of making informed design decisions that lead to the best possible installed system performance are presented.

  14. The impact of changing solar screen rotation angle and its opening aspect ratios on Daylight Availability in residential desert buildings

    KAUST Repository

    Sherif, Ahmed H.; Sabry, Hanan M.; Gadelhak, Mahmoud I.

    2012-01-01

    usually used to diffuse and prevent direct solar penetration into spaces. This paper investigates the impact of changing solar screen axial rotation angle and screen opening aspect ratio on daylighting performance in a typical residential living room space

  15. Improved Windows for Cold Climates

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    2005-01-01

    considerably by reducing the frame width, which results in a larger transparent area causing a larger solar gain but still main-taining a low thermal transmittance. Using three layers of glass with large gaps, using very slim frame profiles, and omitting the edge constructions that normally causes thermal...... windows with improved energy performance. Traditionally evaluation of the energy performance of windows has focused on the thermal transmittance, but as windows differ from the rest of the building envelope by allowing solar energy to enter the building, the total solar energy transmittance is equally...... important. In the heating season in cold climates the solar gain through windows can be utilized for space heating which results in a corresponding reduction in the energy production that is often based on fossil fuels. A suitable quantity for evaluating the energy performance of windows in a simple...

  16. Daylight Management in Mediterranean Cities: When Shortage Is Not the Issue

    OpenAIRE

    Judit Lopez-Besora; Glòria Serra-Coch; Helena Coch; Antonio Isalgue

    2016-01-01

    Natural resources such as daylight and sunlight are highly appreciated in countries with prevailing overcast skies. Taking advantage of this scarce resource contributes to saving energy on artificial lighting. In contrast to northern, southern European cities are distinguished by a large number of days with direct sunlight caused by a propitious climate condition. While it is a positive issue in terms of energy availability, the abundance of it can be counterproductive if management measures ...

  17. Apolux : an innovative computer code for daylight design and analysis in architecture and urbanism

    Energy Technology Data Exchange (ETDEWEB)

    Claro, A.; Pereira, F.O.R.; Ledo, R.Z. [Santa Catarina Federal Univ., Florianopolis, SC (Brazil)

    2005-07-01

    The main capabilities of a new computer program for calculating and analyzing daylighting in architectural space were discussed. Apolux 1.0 was designed to use three-dimensional files generated in graphic editors in the data exchange file (DXF) format and was developed to integrate an architect's design characteristics. An example of its use in a design context development was presented. The program offers fast and flexible manipulation of video card models in different visualization conditions. The algorithm for working with the physics of light is based on the radiosity method representing the surfaces through finite elements divided in small triangular units of area which are fully confronted to each other. The form factors of each triangle are determined in relation to all others in the primary calculation. Visible directions of the sky are also included according to the modular units of a subdivided globe. Following these primary calculations, the different and successive daylighting solutions can be determined under different sky conditions. The program can also change the properties of the materials to quickly recalculate the solutions. The program has been applied in an office building in Florianopolis, Brazil. The four stages of design include initial discussion with the architects about the conceptual possibilities; development of a comparative study based on 2 architectural designs with different conceptual elements regarding daylighting exploitation in order to compare internal daylighting levels and distribution of the 2 options exposed to the same external conditions; study the solar shading devices for specific facades; and, simulations to test the performance of different designs. The program has proven to be very flexible with reliable results. It has the possibility of incorporating situations of the real sky through the input of the Spherical model of real sky luminance values. 3 refs., 14 figs.

  18. Coaxial TW window for power couplers and multipactor considerations

    International Nuclear Information System (INIS)

    Hanus, X.; Mosnier, A.

    1996-01-01

    A Traveling Wave coaxial window has been studied for power couplers purposes. The main features, a reduced electrical field in the ceramic and its multipacting free shape are presented. Multipacting simulations results for other window geometries, using a conical or a cylindrical ceramic are also showed. (author)

  19. Effects of daylight-saving time changes on stock market returns and stock market volatility: rebuttal.

    Science.gov (United States)

    Kamstra, Mark J; Kramer, Lisa A; Levi, Maurice D

    2013-02-01

    In a 2011 reply to our 2010 comment in this journal, Berument and Dogen maintained their challenge to the existence of the negative daylight-saving effect in stock returns reported by Kamstra, Kramer, and Levi in 2000. Unfortunately, in their reply, Berument and Dogen ignored all of the points raised in the comment, failing even to cite the Kamstra, et al. comment. Berument and Dogen continued to use inappropriate estimation techniques, over-parameterized models, and low-power tests and perhaps most surprisingly even failed to replicate results they themselves reported in their previous paper, written by Berument, Dogen, and Onar in 2010. The findings reported by Berument and Dogen, as well as by Berument, Dogen, and Onar, are neither well-supported nor well-reasoned. We maintain our original objections to their analysis, highlight new serious empirical and theoretical problems, and emphasize that there remains statistically significant evidence of an economically large negative daylight-saving effect in U.S. stock returns. The issues raised in this rebuttal extend beyond the daylight-saving effect itself, touching on methodological points that arise more generally when deciding how to model financial returns data.

  20. Daylight Design of Office Buildings: Optimisation of External Solar Shadings by Using Combined Simulation Methods

    Directory of Open Access Journals (Sweden)

    Javier González

    2015-05-01

    Full Text Available Integrating daylight and energy performance with optimization into the design process has always been a challenge for designers. Most of the building environmental performance simulation tools require a considerable amount of time and iterations for achieving accurate results. Moreover the combination of daylight and energy performances has always been an issue, as different software packages are needed to perform detailed calculations. A simplified method to overcome both issues using recent advances in software integration is explored here. As a case study; the optimization of external shadings in a typical office space in Australia is presented. Results are compared against common solutions adopted as industry standard practices. Visual comfort and energy efficiency are analysed in an integrated approach. The DIVA (Design, Iterate, Validate and Adapt plug-in for Rhinoceros/Grasshopper software is used as the main tool, given its ability to effectively calculate daylight metrics (using the Radiance/Daysim engine and energy consumption (using the EnergyPlus engine. The optimization process is carried out parametrically controlling the shadings’ geometries. Genetic Algorithms (GA embedded in the evolutionary solver Galapagos are adopted in order to achieve close to optimum results by controlling iteration parameters. The optimized result, in comparison with conventional design techniques, reveals significant enhancement of comfort levels and energy efficiency. Benefits and drawbacks of the proposed strategy are then discussed.

  1. Transition into daylight saving time influences the fragmentation of the rest-activity cycle

    Directory of Open Access Journals (Sweden)

    Tuulio-Henriksson Annamari

    2006-01-01

    Full Text Available Abstract Background Daylight saving time is widely adopted. Little is known about its influence on the daily rest-activity cycles. We decided to explore the effects of transition into daylight saving time on the circadian rhythm of activity. Methods We monitored the rest-activity cycles with the use of wrist-worn accelerometer on a sample of ten healthy adults for ten days around the transition into summer time. Identical protocols were carried out on the same individuals in two consecutive years, yielding data on 200 person-days for analysis in this study. Results There was no significant effect on the rest-activity cycle in the sample as a whole. Fragmentation of the rest-activity cycle was enhanced in a subgroup of persons having sleep for eight hours or less (P = 0.04 but reduced in those who preferred to sleep for more than eight hours per night (P = 0.05. The average level of motor activity was increased in persons having the morning preference for daily activity patterns (P = 0.01. Conclusion Transition into daylight saving time may have a disruptive effect on the rest-activity cycle in those healthy adults who are short-sleepers or more of the evening type.

  2. Making daylighting work. Learning from failures to improve the design and implementation process

    Energy Technology Data Exchange (ETDEWEB)

    Vaidya, Prasad; McDougall, Tom; Steinbock, Jason; Douglas, James; Eijadi, David [The Weidt Group, Berkeley, CA (United States)

    2005-07-01

    Daylighting, hailed as a cornerstone of sustainable building design, is the primary passive solar design strategy in commercial buildings. It has the potential to significantly reduce lighting energy, which can be 40% or more of the energy cost of a commercial building. We have found that projects with daylighting often do not provide the expected energy savings. In a risk-averse construction industry, even limited failures can dramatically slow the advance of valid technologies. There are numerous reasons for failure: natural light sources are complex and vary through the day and year; implementation requires coordination between different building design and construction trades; the documentation and specification of the controls equipment is often inadequate; and calibration after installation is rarely done well and can be confusing and time consuming. In this paper, we provide four case studies as representative examples where daylighting did not deliver the expected energy savings. We identify the primary modes of failure and provide a template for each mode for easier problem resolution in the future. Through a detailed analysis of the case studies, we identify problem areas in the design and implementation process; we propose a more generalized solution set for design steps, documentation requirements and implementation checks that increase the chances of success.

  3. The shift to and from daylight savings time and motor vehicle crashes.

    Science.gov (United States)

    Lambe, M; Cummings, P

    2000-07-01

    The objective of the study was to examine whether the shifts to and from daylight savings time in Sweden have short-term effects on the incidence of traffic crashes. A database maintained by the Swedish National Road Administration was used to examine crashes from 1984 through 1995, that occurred on state roads the Monday preceding, the Monday immediately after (index Monday), and the Monday 1 week after the change to daylight savings time in the spring and for the corresponding three Mondays in the autumn. The Mondays 1 week before and after the time changes were taken as representing the expected incidence of crashes. Crash incidence was calculated per 1000 person-years using population estimates for each year of the study. The association between 1 h of possible sleep loss and crash incidence was estimated by the incidence rate ratio from negative binomial regression. The incidence rate ratio was 1.04 (95% CI, 0.92-1.16) for a Monday on which drivers were expected to have had 1 h less sleep, compared with other Mondays. In the spring, the incidence rate ratio for crashes was 1.11 (95% CI, 0.93-1.31) for Mondays after the time change compared to other spring Mondays. The corresponding rate ratio for the fall was 0.98 (95% CI, 0.84-1.15) It was concluded that the shift to and from daylight savings time did not have measurable important immediate effects on crash incidence in Sweden.

  4. Daylighting and energy performance of a building for composite climate: An experimental study

    Directory of Open Access Journals (Sweden)

    Madhu Sudan

    2016-12-01

    Full Text Available The present study includes overall energy saving through thermal as well as daylighting for composite climate for the building known as SODHA BERS COMPLEX (SBC situated at Varanasi, India. The building has been designed including all the passive concepts for thermal comfort as well daylighting to maximize the use of natural lighting for the occupants in day to day activities. This approach can be useful for multi-story building for rural and urban areas for both residential and commercial buildings. The energy saving potential and corresponding CO2 mitigation have been determined for different lifetimes of the building. The energy matrices namely energy payback time (EPBT, energy production factor (EPF and life cycle conversion efficiency (LCCE of the building have also been estimated by considering overall energy saving. An annual energy saving has been obtained as 3675.61 kW h due to daylight concept by considering different Zones in each floors of the building. Further, the EPBT has been determined as 49.25 years and 34.73 years for average 4 °C and 6 °C temperature difference between ambient and room, respectively. It has been found that when thermal heat gain increases in the building LCCE and EPF increase.

  5. Tokamak physics experiment: Diagnostic windows study

    International Nuclear Information System (INIS)

    Merrigan, M.; Wurden, G.A.

    1995-11-01

    We detail the study of diagnostic windows and window thermal stress remediation in the long-pulse, high-power Tokamak Physics Experiment (TPX) operation. The operating environment of the TPX diagnostic windows is reviewed, thermal loads on the windows estimated, and cooling requirements for the windows considered. Applicable window-cooling technology from other fields is reviewed and its application to the TPX windows considered. Methods for TPX window thermal conditioning are recommended, with some discussion of potential implementation problems provided. Recommendations for further research and development work to ensure performance of windows in the TPX system are presented

  6. Use of Daylight and Aesthetic Image of Glass Facades in Contemporary Buildings

    Science.gov (United States)

    Roginska-Niesluchowska, Malgorzata

    2017-10-01

    The paper deals with the architecture of contemporary buildings in respect to their aesthetic image created by the use of natural light. Sustainability is regarded as a governing principle of contemporary architecture, where daylighting is an important factor as it affects energy consumption and environmental quality of the space inside a building. Environmental awareness of architecture, however, involves a much wider and more holistic view of design. The quality of sustainable architecture can be considered in its aesthetic and cultural context with regard to landscape, local tradition, and connection to the surrounding world. This approach is associated with the social mission of architecture, i.e. providing appropriate space for living, facilitating social relations and having positive impact on people. The purpose of the research is to study the use of daylight in creating an aesthetic image of contemporary buildings. The author focuses mainly on public buildings largely dedicated to art and culture which satisfy high functional and aesthetic requirements. The paper examines the genesis and current trends in the aesthetic image of modern buildings which use daylight as the main design strategy, focusing on the issues of glass facades. The main attention is given to the shaping of representative public areas which feature the glass facades. The research has been based on a case study, critical review of literature review, observation and synthesis. The study identifies and classifies different approaches to using daylight in these areas and highlights changes in the aesthetics of architecture made of glass, which uses daylight as the main design strategy. These changes are primarily caused by the development and spreading of new glazing materials and the use of digital method of design. The influence of light and its mode depends on glass materials but also on the local conditions of the site, and has a significant impact on the relationship between

  7. Transparent solar cell window module

    Energy Technology Data Exchange (ETDEWEB)

    Chau, Joseph Lik Hang; Chen, Ruei-Tang; Hwang, Gan-Lin; Tsai, Ping-Yuan [Nanopowder and Thin Film Technology Center, ITRI South, Industrial Technology Research Institute, Tainan County 709 (China); Lin, Chien-Chu [I-Lai Acrylic Corporation, Tainan City (China)

    2010-03-15

    A transparent solar cell window module based on the integration of traditional silicon solar cells and organic-inorganic nanocomposite material was designed and fabricated. The transparent solar cell window module was composed of a nanocomposite light-guide plate and traditional silicon solar cells. The preparation of the nanocomposite light-guide plate is easy without modification of the traditional casting process, the nanoparticles sol can be added directly to the polymethyl methacrylate (PMMA) monomer syrup during the process. The solar energy collected by this window can be used to power up small household electrical appliances. (author)

  8. Big Book of Windows Hacks

    CERN Document Server

    Gralla, Preston

    2008-01-01

    Bigger, better, and broader in scope, the Big Book of Windows Hacks gives you everything you need to get the most out of your Windows Vista or XP system, including its related applications and the hardware it runs on or connects to. Whether you want to tweak Vista's Aero interface, build customized sidebar gadgets and run them from a USB key, or hack the "unhackable" screensavers, you'll find quick and ingenious ways to bend these recalcitrant operating systems to your will. The Big Book of Windows Hacks focuses on Vista, the new bad boy on Microsoft's block, with hacks and workarounds that

  9. Production management of window handles

    Directory of Open Access Journals (Sweden)

    Manuela Ingaldi

    2014-12-01

    Full Text Available In the chapter a company involved in the production of aluminum window and door handles was presented. The main customers of the company are primarily companies which produce PCV joinery and wholesalers supplying these companies. One chosen product from the research company - a single-arm pin-lift window handle - was described and its production process depicted technologically. The chapter also includes SWOT analysis conducted in the research company and the value stream of the single-arm pin-lift window handle.

  10. Windows 8 visual quick tips

    CERN Document Server

    McFedries, Paul

    2012-01-01

    Easy-in, easy-out format covers all the bells and whistles of Windows 8 If you want to learn how to work smarter and faster in Microsoft's Windows 8 operating system, this easy-to-use, compact guide delivers the goods. Designed for visual learners, it features short explanations and full-color screen shots on almost every page, and it's packed with timesaving tips and helpful productivity tricks. From enhancing performance and managing digital content to setting up security and much more, this handy guide will help you get more out of Windows 8. Uses full-color screen shots and short, step-by-

  11. Windows Phone 7 Made Simple

    CERN Document Server

    Trautschold, Martin

    2011-01-01

    With Windows Phone 7, Microsoft has created a completely new smartphone operating system that focuses on allowing users to be productive with their smartphone in new ways, while offering seamless integration and use of Microsoft Office Mobile as well as other productivity apps available in the Microsoft App Store. Windows Phone 7 Made Simple offers a clear, visual, step-by-step approach to using your Windows Phone 7 smartphone, no matter what the manufacturer. Author Jon Westfall is an expert in mobile devices, recognized by Microsoft as a "Most Valuable Professional" with experience

  12. Grab Windows training opportunities; check CERN Windows roadmap!

    CERN Multimedia

    IT Department

    2011-01-01

    CERN Operating Systems and Information Services group (IT-OIS) actively monitors market trends to check how new software products correspond to CERN needs. In the Windows world, Windows 7 has been a big hit, with over 1500 Windows 7 PCs within less than a year since its support was introduced at CERN. No wonder: Windows XP is nearly 10 years old and is steadily approaching the end of its life-cycle. At CERN, support for Windows XP will stop at the end of December 2012. Compared to Vista, Windows 7 has the same basic hardware requirements, but offers higher performance, so the decision to upgrade is rather straightforward. CERN support for Vista will end in June 2011. In the world of Microsoft Office, version 2007 offers better integration with the central services than the older version 2003. Progressive upgrade from 2003 to 2007 is planned to finish in September 2011, but users are encouraged to pro-actively upgrade at their convenience. Please note that Office 2007 brings an important change in the area of ...

  13. Influence of daylight on the fate of silver and zinc oxide nanoparticles in natural aquatic environments.

    Science.gov (United States)

    Odzak, Niksa; Kistler, David; Sigg, Laura

    2017-07-01

    Nanoparticles, such as silver (Ag-NP) and zinc oxide (ZnO-NP), are increasingly used in many consumer products. These nanoparticles (NPs) will likely be exposed to the aquatic environment (rain, river, lake water) and to light (visible and UV) in the products where they are applied, or after those products are discharged. Dissolution of Ag-NP and ZnO-NP is an important process because the dissolved Ag + and Zn 2+ are readily available and toxic for aquatic organisms. The objective of this study was to investigate the role of daylight (UV and visible) for the fate of engineered Ag-NP and ZnO-NPs in different types of natural waters. Ag-NP and ZnO-NP were exposed to rainwater, river Rhine, and lake waters (Greifen, Lucerne, Cristallina, Gruère) under different light conditions (no light, UV 300-400 nm and visible light 400-700 nm) for up to 8 days. Stronger agglomeration of Ag-NP was observed in the waters with higher ionic strength in comparison to those with lower ionic strength. Visible light tended to increase the dissolution of Ag-NP under most natural water conditions in comparison to dark conditions, whereas UV-light led to decreased dissolved Ag + after longer exposure time. These effects illustrate the dynamic interactions of Ag-NP with light, which may lead both to increased oxidation and to increased reduction of Ag + by organic compounds under UV-light. In the case of ZnO-NP, agglomeration occurred at higher ionic strength, but the effects of pH were predominant for dissolution, which occurred up to concentrations close to the solubility limit of ZnO(s) at pH around 8.2 and to nearly complete dissolution of ZnO-NP at lower pH (pH 4.8-6.5), with both visible and UV-light facilitating dissolution. This study thus shows that light conditions play an important role in the dissolution processes of nanoparticles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. One-pot solvothermal synthesis of highly efficient, daylight active and recyclable Ag/AgBr coupled photocatalysts with synergistic dual photoexcitation

    International Nuclear Information System (INIS)

    Zhang, Caihong; Ai, Lunhong; Li, Lili; Jiang, Jing

    2014-01-01

    Highlights: • Ag/AgBr photocatalysts were controllably synthesized by solvothermal process. • Ag/AgBr composites showed excellent daylight driven photocatalytic activity. • The remarkable activity is attributed to the synergistic dual photoexcitation. -- Abstract: Efficient light harvesting has been considered to be critical for manipulating the photocatalytic behavior of photocatalysts, because it directly determines the generation of reactive redox charge carriers involved in photoreaction process. In this study, we present a successful example on efficient conversion of solar energy by Ag/AgBr coupled photocatalysts that hold unique synergistic dual photoexcitation. A series of Ag/AgBr coupled photocatalysts were controllably synthesized by an easily manipulated mild solvothermal process. The physicochemical properties of the as-prepared Ag/AgBr coupled photocatalysts were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), X-ray energy dispersive spectroscopy (EDS) and UV–vis diffuse reflectance spectroscopy (DRS). The results showed the solvothermal reaction time played key role for control of crystalline structure, morphology, composition, and visible light absorption ability of the resulting photocatalysts. The as-prepared Ag/AgBr coupled photocatalysts exhibited remarkable photocatalytic performance and good reusability for decomposing organic dyes in aqueous solution under the irradiation of commercial 20 W cool daylight fluorescent lamp, owing to the synergistic dual photoexcitation cooperating between plasmonic Ag nanoparticles and narrow-band-gap AgBr

  15. Peliohjelmointi Windows Phone 8:lle

    OpenAIRE

    Bäckström, Toni

    2014-01-01

    Tässä insinöörityössä tutustutaan Windows Phone 8 -mobiilikäyttöjärjestelmään peliohjelmoijan näkökulmasta. Työn tavoitteena oli erityisesti esitellä Microsoftin itse kehittämiä XNA- ja DirectX-peliohjelmointikirjastoja teoriassa ja käytännössä. Työn aluksi käydään läpi hieman Windows Phonen historiaa ja yleisesti kehittämistä Windows Phone 8:lle. Tämän jälkeen luodaan katsaus Windows Phone 8:aan pelialustana. Työn suurin osuus on XNA:n ja DirectX:n esittely teoriassa; kummastakin men...

  16. Effect of Various External Shading Devices on Windows for Minimum Heat Gain and Adequate Day lighting into Buildings of Hot and Dry Climatic Zone in India

    Directory of Open Access Journals (Sweden)

    Kirankumar Gorantla

    2018-01-01

    Full Text Available Glass is the major component of the building envelope to provide visual comfort to inside the buildings. In général clear and bronze glass was used as a main building envelope for both residential and commercial buildings to provide better day lighting into the buildings. If we use more glass area as a building envelope more radiation allows into the buildings. So that it is necessary to reduce more solar radiation and provide sufficient daylight factor inside the building's through glass windows with the help of external devices called shading devices. In this work four shading devices was tried on bronze glass window to find the heat gain and daylighting into buildings. This paper presents the experimental measurement of spectral characteristics of bronze glass which include transmission and reflection in entire solar spectrum region (300nm-2500nm based on ASTM standards. A MATLAB code was developed to compute visible and solar optical properties as per the British standards. A building model was designed by design builder software tool. 40% window to wall ratio was considered for building models, thermal and day lighting analysis of buildings through windows was carried out in Energy plus software tool for hot and dry climatic zone of India.

  17. A window on urban sustainability

    International Nuclear Information System (INIS)

    Stigt, Rien van; Driessen, Peter P.J.; Spit, Tejo J.M.

    2013-01-01

    Sustainable urban development requires the integration of environmental interests in urban planning. Although various methods of environmental assessment have been developed, plan outcomes are often disappointing due to the complex nature of decision-making in urban planning, which takes place in multiple arenas within multiple policy networks involving diverse stakeholders. We argue that the concept of ‘decision windows’ can structure this seemingly chaotic chain of interrelated decisions. First, explicitly considering the dynamics of the decision-making process, we further conceptualized decision windows as moments in an intricate web of substantively connected deliberative processes where issues are reframed within a decision-making arena, and interests may be linked within and across arenas. Adopting this perspective in two case studies, we then explored how decision windows arise, which factors determine their effectiveness and how their occurrence can be influenced so as to arrive at more sustainable solutions. We conclude that the integration of environmental interests in urban planning is highly dependent on the ability of the professionals involved to recognize and manipulate decision windows. Finally, we explore how decision windows may be opened. -- Highlights: • Decision-making about sustainable urban development occurs in networks. • The concept of ‘decision windows’ was further elaborated. • Decision windows help understand how environmental interests enter decision-making. • Decision windows can, to some extent, be influenced

  18. A window on urban sustainability

    Energy Technology Data Exchange (ETDEWEB)

    Stigt, Rien van, E-mail: rien.vanstigt@hu.nl [Research Center for Technology and Innovation, Utrecht University of Applied Sciences, P.O. Box 182, 3500 AD Utrecht (Netherlands); Driessen, Peter P.J., E-mail: p.driessen@uu.nl [Copernicus Institute of Sustainable Development, Faculty of Geosciences, Utrecht University, P.O. Box 80.115, 3508 TC Utrecht (Netherlands); Spit, Tejo J.M., E-mail: T.J.M.Spit@uu.nl [Department of Human Geography and Spatial Planning, Faculty of Geosciences, Utrecht University, P.O. Box 80.115, 3508 TC Utrecht (Netherlands)

    2013-09-15

    Sustainable urban development requires the integration of environmental interests in urban planning. Although various methods of environmental assessment have been developed, plan outcomes are often disappointing due to the complex nature of decision-making in urban planning, which takes place in multiple arenas within multiple policy networks involving diverse stakeholders. We argue that the concept of ‘decision windows’ can structure this seemingly chaotic chain of interrelated decisions. First, explicitly considering the dynamics of the decision-making process, we further conceptualized decision windows as moments in an intricate web of substantively connected deliberative processes where issues are reframed within a decision-making arena, and interests may be linked within and across arenas. Adopting this perspective in two case studies, we then explored how decision windows arise, which factors determine their effectiveness and how their occurrence can be influenced so as to arrive at more sustainable solutions. We conclude that the integration of environmental interests in urban planning is highly dependent on the ability of the professionals involved to recognize and manipulate decision windows. Finally, we explore how decision windows may be opened. -- Highlights: • Decision-making about sustainable urban development occurs in networks. • The concept of ‘decision windows’ was further elaborated. • Decision windows help understand how environmental interests enter decision-making. • Decision windows can, to some extent, be influenced.

  19. Mastering Microsoft Windows Server 2008 R2

    CERN Document Server

    Minasi, Mark; Finn, Aidan

    2010-01-01

    The one book you absolutely need to get up and running with Windows Server 2008 R2. One of the world's leading Windows authorities and top-selling author Mark Minasi explores every nook and cranny of the latest version of Microsoft's flagship network operating system, Windows Server 2008 R2, giving you the most in-depth coverage in any book on the market.: Focuses on Windows Windows Server 2008 R2, the newest version of Microsoft's Windows' server line of operating system, and the ideal server for new Windows 7 clients; Author Mark Minasi is one of the world's leading Windows authorities and h

  20. Modeling illumination performance of plastic optical fiber passive daylighting system

    Energy Technology Data Exchange (ETDEWEB)

    Sulaiman, F; Ahmad, A [Universiti Teknologi MARA, Shah Alam (Malaysia). Faculty of Electrical Engineering; Ahmed, A Z [Universiti Teknologi MARA, Shah Alam (Malaysia). Bureau of Reseaarch and Consultancy

    2006-12-15

    of the most direct methods of utilizing solar energy for energy conservation is to bring natural light indoors to light up an area. This paper reports on the investigation of the feasibility to utilize large core optical fibers to convey and distribute solar light passively throughout residential or commercial structures. The focus of this study is on the mathematical modeling of the illumination performance and the light transmission efficiency of solid core end light fiber for optical day lighting systems. The Meatball simulations features the optical fiber transmittance for glass and plastic fibers, illumination performance over lengths of plastic end-lit fiber, spectral transmission, light intensity loss through the large diameter solid core optical fibers as well as the transmission efficiency of the optical fiber itself. It was found that plastic optical fiber has less transmission loss over the distance of the fiber run which clearly shows that the Plastic Optical Fiber should be optimized for emitting visible light. The findings from the analysis on the performance of large diameter optical fibers for day lighting systems seems feasible for energy efficient lighting system in commercial or residential buildings.

  1. Modeling illumination performance of plastic optical fiber passive daylighting system

    International Nuclear Information System (INIS)

    Sulaiman, F.; Ahmad, A.; Ahmed, A.Z.

    2006-01-01

    One of the most direct methods of utilizing solar energy for energy conservation is to bring natural light indoors to light up an area. This paper reports on the investigation of the feasibility to utilize large core optical fibers to convey and distribute solar light passively throughout residential or commercial structures. The focus of this study is on the mathematical modeling of the illumination performance and the light transmission efficiency of solid core end light fiber for optical day lighting systems. The Meatball simulations features the optical fiber transmittance for glass and plastic fibers, illumination performance over lengths of plastic end-lit fiber, spectral transmission, light intensity loss through the large diameter solid core optical fibers as well as the transmission efficiency of the optical fiber itself. It was found that plastic optical fiber has less transmission loss over the distance of the fiber run which clearly shows that the Plastic Optical Fiber should be optimized for emitting visible light. The findings from the analysis on the performance of large diameter optical fibers for day lighting systems seems feasible for energy efficient lighting system in commercial or residential buildings

  2. Nonperturbative results for two-index conformal windows

    International Nuclear Information System (INIS)

    Bergner, Georg; Ryttov, Thomas A.; Sannino, Francesco

    2015-01-01

    Via large and small N c relations we derive nonperturbative results about the conformal window of two-index theories. Using Schwinger-Dyson methods as well as four-loops results we estimate subleading corrections and show that naive large number of colors extrapolations are unreliable when N c is less than about six. Nevertheless useful nonperturbative inequalities for the size of the conformal windows, for any number of colors, can be derived. By further observing that the adjoint conformal window is independent of the number of colors we argue, among other things, that: the large N c two-index conformal window is twice the conformal window of the adjoint representation (which can be determined at small N c ) expressed in terms of Dirac fermions; lattice results for adjoint matter can be used to provide independent information on the conformal dynamics of two-index theories such as SU(N c ) with two and four symmetric Dirac flavors.

  3. Context Switching with Multiple Register Windows: A RISC Performance Study

    Science.gov (United States)

    Konsek, Marion B.; Reed, Daniel A.; Watcharawittayakul, Wittaya

    1987-01-01

    Although previous studies have shown that a large file of overlapping register windows can greatly reduce procedure call/return overhead, the effects of register windows in a multiprogramming environment are poorly understood. This paper investigates the performance of multiprogrammed, reduced instruction set computers (RISCs) as a function of window management strategy. Using an analytic model that reflects context switch and procedure call overheads, we analyze the performance of simple, linearly self-recursive programs. For more complex programs, we present the results of a simulation study. These studies show that a simple strategy that saves all windows prior to a context switch, but restores only a single window following a context switch, performs near optimally.

  4. Laser induced damage and fracture in fused silica vacuum windows

    International Nuclear Information System (INIS)

    Campbell, J.H.; Hurst, P.A.; Heggins, D.D.; Steele, W.A.; Bumpas, S.E.

    1996-11-01

    Laser-induced damage, that initiates catastrophic fracture, has been observed in large (≤61 cm dia) fused silica lenses that also serve as vacuum barriers in Nova and Beamlet lasers. If the elastic stored energy in the lens is high enough, the lens will fracture into many pieces (implosion). Three parameters control the degree of fracture in the vacuum barrier window: elastic stored energy (tensile stress), ratio of window thickness to flaw depth, and secondary crack propagation. Fracture experiments were conducted on 15-cm dia fused silica windows that contain surface flaws caused by laser damage. Results, combined with window failure data on Beamlet and Nova, were used to develop design criteria for a ''fail-safe'' lens (that may catastrophically fracture but not implode). Specifically, the window must be made thick enough so that the peak tensile stress is less than 500 psi (3.4 MPa) and the thickness/critical flaw size is less than 6. The air leak through the window fracture and into the vacuum must be rapid enough to reduce the load on the window before secondary crack growth occurs. Finite element stress calculations of a window before and immediately following fracture into two pieces show that the elastic stored energy is redistributed if the fragments ''lock'' in place and thereby bridge the opening. In such cases, the peak stresses at the flaw site can increase, leading to further (i.e. secondary) crack growth

  5. A study on the performance enhancement of low-temperature solar applications : Daylighting and Adsorption Desalination System

    International Nuclear Information System (INIS)

    Kim, Yeong Min

    2011-02-01

    Thermal applications of solar energy are categorized by low, medium and high temperature. The present study has explored two major applications of solar energy widely researched and practiced these days. Of these, one deals with the utilization of solar energy for lighting in buildings, which is responsible for a great portion of electricity consumption, especially, for office and public buildings. Rapid improvements in lighting technology harnessing solar energy (daylight) have greatly contributed to radically reduce its consumption levels - and thereby reduce CO 2 emissions and cost. The other case considered here for solar utilization is so-called solar desalination using adsorbents (silica gels). This technology utilizes a silica gel adsorbent (desiccant) as a medium between an evaporator and a condenser to reject and facilitate latent heat of vaporization. Vapour is adsorbed and desorbed between evaporation and condensation phases. 1. Daylighting simulation A lighting upgrade is an obvious step toward improving a building's energy consumption, which could be easily assessed by using computer simulations. The present study has carried out a series of computer simulations for a lightless space as well as an actual classroom (in Jeju National University) when sun pipe systems are installed. They were first modeled by ECOTECT before RADIANCE was called in to conduct lighting analysis. Simulations were performed for equinoxes and solstices when the sun is at its highest altitude, i.e. at noon (12 PM). A lightless space and classroom of the same dimensions revealed the effectiveness of sun pipe systems to improve indoor lighting conditions throughout the year. 2. Development of adsorption desalination system utilizing silica-gel Some major components of an adsorption desalination system were designed and fabricated to assess its desalination efficiency when packs of silica-gel were used at different operating conditions. The amount of fresh water yield was studied

  6. A study on the performance enhancement of low-temperature solar applications : Daylighting and Adsorption Desalination System

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeong Min

    2011-02-15

    Thermal applications of solar energy are categorized by low, medium and high temperature. The present study has explored two major applications of solar energy widely researched and practiced these days. Of these, one deals with the utilization of solar energy for lighting in buildings, which is responsible for a great portion of electricity consumption, especially, for office and public buildings. Rapid improvements in lighting technology harnessing solar energy (daylight) have greatly contributed to radically reduce its consumption levels - and thereby reduce CO{sub 2} emissions and cost. The other case considered here for solar utilization is so-called solar desalination using adsorbents (silica gels). This technology utilizes a silica gel adsorbent (desiccant) as a medium between an evaporator and a condenser to reject and facilitate latent heat of vaporization. Vapour is adsorbed and desorbed between evaporation and condensation phases. 1. Daylighting simulation A lighting upgrade is an obvious step toward improving a building's energy consumption, which could be easily assessed by using computer simulations. The present study has carried out a series of computer simulations for a lightless space as well as an actual classroom (in Jeju National University) when sun pipe systems are installed. They were first modeled by ECOTECT before RADIANCE was called in to conduct lighting analysis. Simulations were performed for equinoxes and solstices when the sun is at its highest altitude, i.e. at noon (12 PM). A lightless space and classroom of the same dimensions revealed the effectiveness of sun pipe systems to improve indoor lighting conditions throughout the year. 2. Development of adsorption desalination system utilizing silica-gel Some major components of an adsorption desalination system were designed and fabricated to assess its desalination efficiency when packs of silica-gel were used at different operating conditions. The amount of fresh water yield was

  7. Daylight Utilization with Light Pipe in Farm Animal Production: A Simulation Approach

    Directory of Open Access Journals (Sweden)

    Alejandro Pacheco Diéguez’

    2016-06-01

    Full Text Available Light pipes offer a passive way to bring daylight inside deep buildings, such as agricultural buildings. However, the lack of reliable performance predictability methods for light pipes represents a major obstacle preventing their widespread use. This paper evaluates a simulation approach for performance prediction and identifies key light pipe design parameters affecting their daylight transmission performance. The study was carried out through continuous monitoring of daylight in two full-scale, identical pig stables fitted with two light pipe systems, Solatube® and Velux®. The experiment included three continuously measuring sensors in each stable and an outdoor sensor during 2013 and 2014. A forward raytracing tool, TracePro®, was used for illuminance prediction and parametric simulations. The simulation results for overcast skies indicated discrepancies between the simulated and average measurement results below 30% in all cases. The discrepancies for clear skies were somewhat higher, i.e., below 30% for 67% of the cases. The higher discrepancies with clear skies were due to the overestimation of absolute sunlight levels and absence of an advanced and detailed optical characterization of the dome collector’s surface. The parametric results have shown that light pipes’ performance is better during summer time, in sunny climates, at low to mid-latitudes, which provides higher solar altitudes than during winter and cloudy climates at high latitudes. Methods to improve the luminous transmittance for low solar altitudes occurring in Scandinavia include: bending or tilting the pipe, increasing the aspect ratio, improving the pipe specular reflectance, tilting the collector to the south, and using optical redirecting system in the collector.

  8. The influence of the lateral distances between buildings on the availability of indoor daylighting

    Directory of Open Access Journals (Sweden)

    Andrea Coelho Laranja

    2014-12-01

    Full Text Available This study addresses aspects related to daylighting in the indoor environment, more specifically the influence of lateral distances between obstructing buildings on the availability of indoor daylighting, taking the height of the buildings and width of the roads into account. In accordance with the adopted methodology, comparisons were made of the percentage of illuminance values of the internal environment by using UDI (Useful Daylight Illuminance ranges on a selected point within an interior environment with an opening oriented to the North. The percentages of illuminance values were generated by simulation using the TropLux program in a rectangular geometry environment inserted in an urban setting in the city of Vitória, Espírito Santo (Latitude 20°19'S. The simulations were carried out for three types of sky patterns recognized by the CIE (Commission Internationale L'aclairage. One of the main results of this study was that, in locations with sky types 3 (overcast, 7 (partly cloudy, and 12 (clear, there were greater variations in the average annual internal illuminance when there were changes in the lateral distances between the obstructing buildings that were not directly in front of the building that was being analyzed. It was also found that in area with sky types 3 (overcast, 7 (partly cloudy, and 12 (clear, changes in the lateral distances between the three obstructing buildings had little effect on percentage changes in the 100≤UDI≤500 lux range and 500≤UDI ≤2000 lux range.

  9. Critical analysis of the daylight saving time; Analisis critico al horario del verano

    Energy Technology Data Exchange (ETDEWEB)

    Romero Paredes Rubio, Hernando [Universidad Autonoma Metropolitana Ciudad-Ixtapalapa, Mexico, D.F., (Mexico)

    2001-07-01

    The critical analysis is presented as a synthesis of the problem untied since the implementation of the daylight saving time. The often related history is retaken to introduce the reader into the context of the causes of a such program. The geometric aspect of the solar trajectories is discussed and the length of the day as a function of the latitude and the time of the year to have technical elements for the time displacement in a certain region. The technical implementation of the daylight saving time based on three elements is justified: time of dawn and the decline (length of the day), national economic motivation and tourism industry. Stands out that although the daylight saving time schedule has a set of social and economic benefits it is not centered in the individual but in the society as a whole. The errors in handling the information and the misinformation are pointed out as the main causes of the controversy, the discord and the political manipulation of competing groups. [Spanish] El analisis critico se presenta como una sintesis del problema desatado desde la implementacion del horario de verano. La historia muchas veces contada se retoma para introducir al lector en el contexto de las causas de un tal programa. Se discute el aspecto geometrico de las trayectorias solares y la longitud del dia como una funcion de la latitud y de la epoca del ano para tener elementos tecnicos para el desplazamiento horario en una region determinada. Se justifica la implementacion tecnica del horario de verano en funcion de tres elementos: hora de alba y del ocaso (longitud del dia), motivacion economica nacional e industria turistica. Se destaca que si bien el horario de verano tiene un conjunto de beneficios sociales y economicos no se centra en el individuo sino en la sociedad en su conjunto. Se senalan los errores de manejo de la informacion y la desinformacion como los principales causantes de la polemica, el desacuerdo y la manipulacion politica de grupos

  10. Overheating and Daylighting; Assessment Tool in Early Design of London’s High-Rise Residential Buildings

    Directory of Open Access Journals (Sweden)

    Bachir Nebia

    2017-08-01

    Full Text Available High-rise residential buildings in dense cities, such as London, are a common response to housing shortage. The apartments in these buildings may experience different levels of thermal and visual comfort, depending on their orientation and floor level. This paper aims to develop simplified tools to predict internal temperatures and daylighting levels, and propose a tool to quickly assess overheating risk and daylight performance in London’s high-rise residential buildings. Single- and double-sided apartments in a high-rise building were compared, and the impact of their floor level, glazing ratio, thermal mass, ventilation strategy and orientation was investigated. Using Integrated Environmental Solutions Virtual Environment (IES VE, temperature and daylight factor results of each design variable were used to develop early design tools to predict and assess overheating risks and daylighting levels. The results indicate that apartments that are more exposed to solar radiations, through either orientation or floor level, are more susceptible to overheat in the summer while exceeding the daylighting recommendations. Different design strategies at different levels and orientations are subsequently discussed.

  11. Effects of Daylight Saving Time changes on stock market volatility: a reply.

    Science.gov (United States)

    Berument, Hakan; Dogan, Nukhet

    2011-12-01

    There is a rich array of evidence that suggests that changes in sleeping patterns affect an individual's decision-making processes. A nationwide sleeping-pattern change happens twice a year when the Daylight Saving Time (DST) change occurs. Kamstra, Kramer, and Levi argued in 2000 that a DST change lowers stock market returns. This study presents evidence that DST changes affect the relationship between stock market return and volatility. Empirical evidence suggests that the positive relationship between return and volatility becomes negative on the Mondays following DST changes.

  12. Effect of short-term simulated daylight exposure on optically brightened papers

    International Nuclear Information System (INIS)

    Green, Phil; Honess, Mike

    2010-01-01

    Two optically brightened commercial papers were subjected to 72 hours continuous exposure to graphic arts daylight simulating fluorescent lamps at 1.4 and 4.4 klux. At the higher illuminance level, a CIELAB colour difference of 1.0 was reached in approximately 3 and 50 hours for the two papers. The colour differences produced by the 1.4 klux exposure were greater than that predicted by assuming a linear relationship between intensity and colour change, by a factor of 1.8.

  13. Development of a new model to predict indoor daylighting: Integration in CODYRUN software and validation

    Energy Technology Data Exchange (ETDEWEB)

    Fakra, A.H., E-mail: fakra@univ-reunion.f [Physics and Mathematical Engineering Laboratory for Energy and Environment (PIMENT), University of La Reunion, 117 rue du General Ailleret, 97430 Le Tampon (French Overseas Dpt.), Reunion (France); Miranville, F.; Boyer, H.; Guichard, S. [Physics and Mathematical Engineering Laboratory for Energy and Environment (PIMENT), University of La Reunion, 117 rue du General Ailleret, 97430 Le Tampon (French Overseas Dpt.), Reunion (France)

    2011-07-15

    Research highlights: {yields} This study presents a new model capable to simulate indoor daylighting. {yields} The model was introduced in research software called CODYRUN. {yields} The validation of the code was realized from a lot of tests cases. -- Abstract: Many models exist in the scientific literature for determining indoor daylighting values. They are classified in three categories: numerical, simplified and empirical models. Nevertheless, each of these categories of models are not convenient for every application. Indeed, the numerical model requires high calculation time; conditions of use of the simplified models are limited, and experimental models need not only important financial resources but also a perfect control of experimental devices (e.g. scale model), as well as climatic characteristics of the location (e.g. in situ experiment). In this article, a new model based on a combination of multiple simplified models is established. The objective is to improve this category of model. The originality of our paper relies on the coupling of several simplified models of indoor daylighting calculations. The accuracy of the simulation code, introduced into CODYRUN software to simulate correctly indoor illuminance, is then verified. Besides, the software consists of a numerical building simulation code, developed in the Physics and Mathematical Engineering Laboratory for Energy and Environment (PIMENT) at the University of Reunion. Initially dedicated to the thermal, airflow and hydrous phenomena in the buildings, the software has been completed for the calculation of indoor daylighting. New models and algorithms - which rely on a semi-detailed approach - will be presented in this paper. In order to validate the accuracy of the integrated models, many test cases have been considered as analytical, inter-software comparisons and experimental comparisons. In order to prove the accuracy of the new model - which can properly simulate the illuminance - a

  14. Daylight illumination-color-contrast tables for full-form objects naturally illuminated objects

    CERN Document Server

    Nagel, M

    1978-01-01

    Daylight Illumination-Color-Contrast Tables for Full-form Objects is the result of a major computational project concerning the illumination, color, and contrast conditions in naturally illuminated objects. The project from which this two-chapter book is derived is originally conceived in support of the various remote sensing and image processing activities of the Deutsche Forschungs- und Versuchsanstalt für Luft- und Raumfahrt, Oberpfaffenhofen, West Germany DFVLR, in particular, those depending on the quantitative photometric and colorimetric evaluation of photographs and other environmental

  15. Integrated control of sun shades, daylight and artificial light; Integreret regulering af solafskaermning, dagslys og kunstlys

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, K.; Christoffersen, J.; Soerensen, Henrik; Jessen, G.

    2011-07-01

    The project established a basis of calculation and a practical basis for optimum choice of solar shading and integrated control strategies for both new buildings and for office, commercial and institutional buildings to be renovated with new calculation models for controlling solar shading integrated in the BSim program. A complete and applicable model for optimum, integrated solar shading control was established, focusing on thermal and visual comfort criteria towards energy consumption for heating, cooling and lighting. A prototype was tested in the daylight laboratory at Danish Building Research Institute-Aalborg University and at University of Southern Denmark. (LN)

  16. Yellowing of coated papers under the action of heat, daylight radiation, and nitrogen oxide gas

    International Nuclear Information System (INIS)

    Mailly, V.; Le Nest, J.F.; Tosio, J.M.S.; Silvy, J.

    1997-01-01

    In the area of coated papers, a high degree of whiteness is often required to carry a quality image. Coated papers however are sensitive to the environment where they are stored and have tendency to yellow. The aim of this work was to study the influence of(i) daylight radiation and (ii) nitrogen oxide gas (NO2 ) on the yellowing of coated papers. In a previous study (l), we had established the presence of NO2 in the environment of some coating machines because of the transformation of ammonium hydroxide (NH4 OH, a component of some coating colors) into nitrogen oxide through the burners of hot air supplier-systems

  17. Daylight saving time can decrease the frequency of wildlife–vehicle collisions

    Science.gov (United States)

    Ellis, William A.; FitzGibbon, Sean I.; Barth, Benjamin J.; Niehaus, Amanda C.; David, Gwendolyn K.; Taylor, Brendan D.; Matsushige, Helena; Melzer, Alistair; Bercovitch, Fred B.; Carrick, Frank; Jones, Darryl N.; Dexter, Cathryn; Gillett, Amber; Predavec, Martin; Lunney, Dan

    2016-01-01

    Daylight saving time (DST) could reduce collisions with wildlife by changing the timing of commuter traffic relative to the behaviour of nocturnal animals. To test this idea, we tracked wild koalas (Phascolarctos cinereus) in southeast Queensland, where koalas have declined by 80% in the last 20 years, and compared their movements with traffic patterns along roads where they are often killed. Using a simple model, we found that DST could decrease collisions with koalas by 8% on weekdays and 11% at weekends, simply by shifting the timing of traffic relative to darkness. Wildlife conservation and road safety should become part of the debate on DST. PMID:27881767

  18. The workplace window view

    DEFF Research Database (Denmark)

    Lottrup, Lene Birgitte Poulsen; Stigsdotter, Ulrika K.; Meilby, Henrik

    2015-01-01

    Office workers’ job satisfaction and ability to work are two important factors for the viability and competitiveness of most companies, and existing studies in contexts other than workplaces show relationships between a view of natural elements and, for example, student performance...... satisfaction, and that high view satisfaction was related to high work ability and high job satisfaction. Furthermore, the results indicated that job satisfaction mediated the effect of view satisfaction on work ability. These findings show that a view of a green outdoor environment at the workplace can...... be an important asset in workforce work ability and job satisfaction....

  19. Daylight photocatalysis performance of biomorphic CeO2 hollow fibers prepared with lens cleaning paper as biotemplate

    International Nuclear Information System (INIS)

    Qian, Junchao; Chen, Feng; Wang, Fang; Zhao, Xiaobing; Chen, Zhigang

    2012-01-01

    Highlights: ► A novel, simple and eco-friendly approach for hierarchical, biomorphic CeO 2 hollow fibers with mesoporous tube walls is presented by using paper as template. ► The biomorphic CeO 2 fibers was composed of nanosheets with bimodal pore-size mesoporous distribution and exhibited high light-harvesting under sunlight irradiation. ► The CeO 2 microfibers biomimicking the natural plant structures have promising application for photodegradation of organic pollutants in water. -- Abstract: Hierarchical, biomorphic CeO 2 hollow fibers with mesoporous tube walls have been fabricated using lens cleaning paper as biotemplates. After sintered at 550 °C in air, the cellulosic fibers of paper were converted into micro-tubes composing of CeO 2 crystallites with grain size about 8 nm. The photocatalytic activity of the CeO 2 fibers was evaluated by photodegradation efficiency of methylene blue in aqueous solution under daylight irradiation. The characterized results show that the CeO 2 fibers faithfully replicated micro-fibrous structure derived from original template and possessed dramatic enhanced photocatalytic activity compared with bulk CeO 2 . This simple biotemplate method provides a cost-effective and eco-friendly route to obtain high performance photocatalysts.

  20. Daylight methyl-aminolevulinate photodynamic therapy versus ingenol mebutate for the treatment of actinic keratoses: an intraindividual comparative analysis.

    Science.gov (United States)

    Genovese, Giovanni; Fai, Dario; Fai, Carlotta; Mavilia, Luciano; Mercuri, Santo R

    2016-05-01

    Daylight-photodynamic therapy (D-PDT) and ingenol mebutate (IM) are novel therapies directed to actinic keratoses (AK). The purpose of our study was to compare effectiveness, tolerability, cosmetic outcome and patient preference of D-PDT versus IM in the treatment of grade I and II AK. Twenty-seven patients with AK on the face or scalp were enrolled. Each patient received, in a 25 cm(2) target area, D-PDT on right side and IM on left side. Overall 323 AK were treated. Both target areas achieved complete response in 40.47% of the cases and average AK clearance rate was similar for D-PDT and IM (p=0.74). In D-PDT areas mean grade II AK clearance rate was lower compared with that of grade I AK (p=0.015). In IM areas grade I and II AK average clearance rates were similar (p=0.28). At week 1 and month 1, mean local skin responses (LSR) score were higher in areas treated with IM. IM areas showed more severe pain and cosmetic sequelae. D-PDT had similar effectiveness to IM, even if IM demonstrated higher grade II AK clearance rate. Tolerability profile was superior for D-PDT in terms of LSR and pain. D-PDT was more cosmetically acceptable. Patients preferred D-PDT to IM in most cases. © 2016 Wiley Periodicals, Inc.

  1. Daylight photocatalysis performance of biomorphic CeO{sub 2} hollow fibers prepared with lens cleaning paper as biotemplate

    Energy Technology Data Exchange (ETDEWEB)

    Qian, Junchao; Chen, Feng [Department of Material Science and Engineering, Jiangsu University, 212013 Zhenjiang (China); Wang, Fang; Zhao, Xiaobing [Department of Materials Science and Engineering, Changzhou University, 213164 Changzhou (China); Chen, Zhigang, E-mail: ziyou1900@gmail.com [Department of Material Science and Engineering, Jiangsu University, 212013 Zhenjiang (China); Jiangsu Key Laboratory for Environment Functional Materials, 215009 Suzhou University of Science and Technology, Suzhou (China); State Key laboratory of Crystal Material, Shandong University, 250100 Jinan (China)

    2012-08-15

    Highlights: ► A novel, simple and eco-friendly approach for hierarchical, biomorphic CeO{sub 2} hollow fibers with mesoporous tube walls is presented by using paper as template. ► The biomorphic CeO{sub 2} fibers was composed of nanosheets with bimodal pore-size mesoporous distribution and exhibited high light-harvesting under sunlight irradiation. ► The CeO{sub 2} microfibers biomimicking the natural plant structures have promising application for photodegradation of organic pollutants in water. -- Abstract: Hierarchical, biomorphic CeO{sub 2} hollow fibers with mesoporous tube walls have been fabricated using lens cleaning paper as biotemplates. After sintered at 550 °C in air, the cellulosic fibers of paper were converted into micro-tubes composing of CeO{sub 2} crystallites with grain size about 8 nm. The photocatalytic activity of the CeO{sub 2} fibers was evaluated by photodegradation efficiency of methylene blue in aqueous solution under daylight irradiation. The characterized results show that the CeO{sub 2} fibers faithfully replicated micro-fibrous structure derived from original template and possessed dramatic enhanced photocatalytic activity compared with bulk CeO{sub 2}. This simple biotemplate method provides a cost-effective and eco-friendly route to obtain high performance photocatalysts.

  2. Windows Server 2012 vulnerabilities and security

    Directory of Open Access Journals (Sweden)

    Gabriel R. López

    2015-09-01

    Full Text Available This investigation analyses the history of the vulnerabilities of the base system Windows Server 2012 highlighting the most critic vulnerabilities given every 4 months since its creation until the current date of the research. It was organized by the type of vulnerabilities based on the classification of the NIST. Next, given the official vulnerabilities of the system, the authors show how a critical vulnerability is treated by Microsoft in order to countermeasure the security flaw. Then, the authors present the recommended security approaches for Windows Server 2012, which focus on the baseline software given by Microsoft, update, patch and change management, hardening practices and the application of Active Directory Rights Management Services (AD RMS. AD RMS is considered as an important feature since it is able to protect the system even though it is compromised using access lists at a document level. Finally, the investigation of the state of the art related to the security of Windows Server 2012 shows an analysis of solutions given by third parties vendors, which offer security products to secure the base system objective of this study. The recommended solution given by the authors present the security vendor Symantec with its successful features and also characteristics that the authors considered that may have to be improved in future versions of the security solution.

  3. The slice is right (an exercise in CT windowing)

    International Nuclear Information System (INIS)

    Whalen, B.

    2003-01-01

    This article was adapted from a poster display presentation and is offered in the form of a workbook exercise. Its object is to teach students and other novices the fine art of CT windowing. When asked how window widths and levels work, I invariably use the analogy of the Range Finder Game from the game show The Price is Right for demonstration purposes. I employ the comparison from the popular game show to demonstrate what window widths and window levels are, and how they work in unison. This exercise employs two minor differences from the TV game. Number one, the monetary scale has been replaced by a CT number scale. Number two, the movable range finder that has a fixed scale on the game show, is replaced by a range finder (WW) scale, which can alter its range. (author)

  4. Travailler avec Windows 7 au CERN (FR)

    CERN Multimedia

    CERN. Geneva

    2010-01-01

    Vue d'ensemble des nouveaux concepts et des changements dans l'interface utilisateur survenus dans Windows 7 depuis les versions antérieures de Windows (XP ou Vista). La mise à disposition de Windows 7 au CERN et son intégration dans l’infrastructure de Windows au CERN seront présentées.

  5. Music@Microsoft.Windows: Composing Ambience

    Science.gov (United States)

    Rickert, Thomas

    2010-01-01

    It is well known, of course, that all Windows versions except for 3.1 have a brief (four to six second) piece of music indicating that Windows is booted and ready for use. While the music may indicate Windows has booted, it bears no immediately discernable relation to the various uses we might actually put Windows to--working, gaming,…

  6. Windows Server 2012 R2 administrator cookbook

    CERN Document Server

    Krause, Jordan

    2015-01-01

    This book is intended for system administrators and IT professionals with experience in Windows Server 2008 or Windows Server 2012 environments who are looking to acquire the skills and knowledge necessary to manage and maintain the core infrastructure required for a Windows Server 2012 and Windows Server 2012 R2 environment.

  7. Windows with improved energy performance

    DEFF Research Database (Denmark)

    Noyé, Peter Anders; Laustsen, Jacob Birck; Svendsen, Svend

    2002-01-01

    According to the Danish energy protocol, Energy 21, one of the goals with highest priority is to reduce the CO2-emission. Energy consumption for domestic heating is a major contributor to the CO2-emission; hence one of the primary efforts to reach the goal is by saving energy in the households...... performances. During the last 20 years the U-value of the glazing part of windows has been improved considerably, but the frame part has not followed the same development with respect to energy performance. Therefore an increasingly large part of the total heat loss through windows is relating to the frame...... part, for which reason, as far as energy efficiency and total economy are concerned, it has become more interesting to further develop frame structures. Traditionally, the energy performance of windows has primarily been characterised by the heat loss coefficient, U-value. However as the heat loss has...

  8. Windows 7 is supported at CERN

    CERN Multimedia

    IT Department

    2010-01-01

    The new version of the Windows operating system - Windows 7 - is now officially supported at CERN. Windows 7 32-bit is now the default operating system for the new computers at CERN. What’s new in Windows 7 Users of Windows XP will find many new features and options. Users of Windows Vista will feel very familiar with one major difference: higher performance and better responsiveness of the operating system. Other enhancements include: refined Aero desktop that makes it easier to navigate between your different application windows; new snapping windows that allows user to resize a window simply by dragging it to the edge of the screen and “pin” that allows grouping and arranging often accessed applications on the taskbar. Windows 7 introduces the new concept of libraries – containers for user files that have links to different local or network folders. By default, users can see four libraries: Documents, Music, Pictures and Videos. These libraries point to the cor...

  9. *New* CRITICAL Windows Security patch

    CERN Multimedia

    2003-01-01

    On 10 September 2003, Microsoft issued a new CRITICAL security patch, MS03-039. It must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security hole and patch for MS03-039 (which also includes MS03-026) are at: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp

  10. *New*: CRITICAL Windows Security patch

    CERN Multimedia

    2003-01-01

    On 10 September 2003, Microsoft issued a new CRITICAL security patch, MS03-039. It must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security hole and patch for MS03-039 (which also includes MS03-026) are at: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp

  11. Microsoft Windows Server Administration Essentials

    CERN Document Server

    Carpenter, Tom

    2011-01-01

    The core concepts and technologies you need to administer a Windows Server OS Administering a Windows operating system (OS) can be a difficult topic to grasp, particularly if you are new to the field of IT. This full-color resource serves as an approachable introduction to understanding how to install a server, the various roles of a server, and how server performance and maintenance impacts a network. With a special focus placed on the new Microsoft Technology Associate (MTA) certificate, the straightforward, easy-to-understand tone is ideal for anyone new to computer administration looking t

  12. Windows Vista Administrator's Pocket Guide

    CERN Document Server

    Stanek, William R

    2007-01-01

    Portable and precise, this pocket-sized guide delivers immediate answers for the day-to-day administration of Windows Vista. Zero in on core support and maintenance tasks using quick-reference tables, instructions, and lists. You'll get the precise information you need to solve problems and get the job done-whether you're at your desk or in the field! Get fast facts to: Install and configure Windows Vista-and optimize the user workspaceMaintain operating system components, hardware devices, and driversCreate user and group accounts-and control rights and permissionsAdminister group policy se

  13. Transparent aerogel Windows

    DEFF Research Database (Denmark)

    Jensen, Karsten Ingerslev; Schultz, Jørgen Munthe

    the supercritical washing step included in the drying phase. At the same time the production plant have been modified to recycle most of the chemicals involved in the production process. A large number of aerogel glazing prototypes have been made with partly evacuated aerogel in between two layers of low iron...... and anti reflection treated glass panes with an airtight edge seal solution based on multi-layered plastic foil developed for vacuum insulation purposes. The edge seal solution shows only a very limited thermal bridge effect. The final glazing has a total solar energy transmittance about 87% and a U...

  14. Verification of simple illuminance based measures for indication of discomfort glare from windows

    DEFF Research Database (Denmark)

    Karlsen, Line Røseth; Heiselberg, Per Kvols; Bryn, Ida

    2015-01-01

    predictions of discomfort glare from windows already in the early design stage when decisions regarding the façade are taken. This study focus on verifying if simple illuminance based measures like vertical illuminance at eye level or horizontal illuminance at the desk are correlated with the perceived glare...... reported by 44 test subjects in a repeated measure design occupant survey and if the reported glare corresponds with the predictions from the simple Daylight Glare Probability (DGPs) model. Large individual variations were seen in the occupants’ assessment of glare in the present study. Yet, the results...... confirm that there is a statistically significant correlation between both vertical eye illuminance and horizontal illuminance at the desk and the occupants’ perception of glare in a perimeter zone office environment, which is promising evidence towards utilizing such simple measures for indication...

  15. Cloud and radiance measurements with the VIS/NIR Daylight Whole Sky Imager at Lindenberg (Germany)

    Energy Technology Data Exchange (ETDEWEB)

    Feister, U. [Deutscher Wetterdienst, Meteorologisches Observatorium Lindenberg (Germany); Shields, J. [Scripps Inst. of Oceanography, Univ. of California, San Diego (United States)

    2005-10-01

    Ground-based cloud data acquired with the whole sky imager (WSI) are analyzed in relation to measurements of solar radiation performed at the Lindenberg Meteorological Observatory. Cloud fractions derived by the cloud detection algorithm from WSI images acquired during daylight hours between 2002 and 2004 are compared with conventional cloud observations for the two sites Potsdam and Lindenberg, and also with ceilometer data of cloud-base heights at Lindenberg. The comparison statistics are discussed in the context of different principles of measurement. A few case studies illustrate the strong scattering effect of clouds on solar radiance and irradiance measured at the ground in different spectral regions. Particularly clouds close to the apparent position of the sun lead to strong enhancements of solar diffuse irradiance incident on horizontal planes and hemispheres that substantially exceed corresponding clear-sky values. Irradiances derived from WSI sky radiance fields are shown in comparison to pyranometer data of diffuse irradiance and radiative transfer model calculations performed for clear sky conditions. Examples of spectral sky radiances with moving contrails illustrate the significant enhancement the contrails have compared to clear sky, even though they may have a relatively small direct effect on global irradiance values. As contrails are observed at Lindenberg for about 18 to 19% of daylight hours, and part of them become clouds, the indirect impact of these changes on solar irradiance received at the ground may not be negligible. (orig.)

  16. Development of Optical Fiber-Based Daylighting System and Its Comparison

    Directory of Open Access Journals (Sweden)

    Irfan Ullah

    2015-07-01

    Full Text Available Fiber-optic daylighting systems have been shown to be a promising and effective way to transmit sunlight in the interior space whilst reducing electric lighting energy consumption. To increase efficiency in terms of providing uniform illumination in the interior, the current need is to illuminate optical fiber-bundle with uniform light flux. To this end, we propose a method for achieving collimated light, which illuminates the fiber-bundle uniformly. Light is collected through a parabolic concentrator and focused toward a collimating lens, which distributes the light over each optical fiber. An optics diffusing structure is utilized at the end side of the fiber bundle to spread light in the interior. The results clearly reveal that the efficiency in terms of uniform illumination, which also reduces the heat problem for optical fibers, is improved. Furthermore, a comparison study is conducted between current and previous approaches. As a result, the proposed daylighting system turns out convenient in terms of energy saving and reduction in greenhouse gas emissions.

  17. Light-scattering properties of a Venetian blind slat used for daylighting applications

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Annica M. [Department of Engineering Sciences, Angstroem Laboratory, Uppsala University (Sweden); Jonsson, Jacob C. [Environmental Energy Technology Division, Lawrence Berkeley National Laboratory, Berkeley, CA (United States)

    2010-12-15

    The low cost, simplicity, and aesthetic appearance of external and internal shading devices, make them commonly used for daylighting and glare-control applications. Shading devices, such as Venetian blinds, screens, and roller shades, generally exhibit light scattering and/or light redirecting properties. This requires the bi-directional scattering distribution function (BSDF) of the material to be known in order to accurately predict the daylight distribution and energy flow through the fenestration system. Acquiring the complete BSDF is not a straightforward task, and to complete the process it is often required that a model is used to complement the measured data. In this project, a Venetian blind slat with a white top surface and a brushed aluminum bottom surface was optically characterized. A goniophotometer and an integrating sphere spectrophotometer were used to determine the angle resolved and hemispherical reflectance of the sample, respectively. The acquired data were fitted to a scattering model providing one Lambertian and one angle dependent description of the surface properties. These were used in combination with raytracing to obtain the complete BSDFs of the Venetian blind system. (author)

  18. Low levels of vitamin D poorly responsive to daylight exposure in patients with therapy-resistant schizophrenia.

    Science.gov (United States)

    Bogers, Jan P.A.M.; Bostoen, Tijmen; Broekman, Theo G.

    2016-01-01

    Low vitamin D levels are associated with schizophrenia, but the possible association between vitamin D levels and illness severity or duration of exposure to daylight has barely been investigated. To compare vitamin D levels in therapy-refractory severely ill schizophrenia patients and members of staff. To investigate the influence of daylight exposure on vitamin D levels in patients. Vitamin D was measured in patients with therapy-resistant schizophrenia in April, after the winter, and in patients and staff members in June, after an exceptionally sunny spring. Vitamin D levels in April and June were compared in patients, and levels in June were compared in patients and staff. The influence of daylight was taken into account by comparing the time patients spent outdoors during the day with the recommended minimum time for adequate vitamin D synthesis, and by comparing time spent outdoors in patients and staff. Patients had high rates of vitamin D deficiency (79-90%) and lower levels of vitamin D than staff members (p vitamin D levels did not normalize, despite the considerably longer than recommended exposure of the skin to daylight (p vitamin D deficiency of therapy-resistant schizophrenia patients is pronounced and cannot be explained by differences in skin pigmentation or by an inactive, indoor lifestyle on the ward. Even theoretically sufficient exposure of the patients to daylight did not ameliorate the low vitamin D levels. While vitamin D deficiency probably plays a role in somatic health problems, it may also play a role in schizophrenia. Interestingly, exposure to daylight during an unusually sunny spring was not sufficient to correct the vitamin D deficiency seen in the patients. This emphasizes the need to measure and correct vitamin D levels in these patients.

  19. High power tests of beryllium oxide windows to the lower hybrid current drive launcher in JET

    International Nuclear Information System (INIS)

    Ekedahl, A.; Brandon, M.; Finburg, P.

    1999-01-01

    The vacuum windows to the 3.70 GHz Lower Hybrid Current Drive (LHCD) system in JET were originally designed to withstand 350 kW for 20 s with VSWR ≤ 1.8. High power RF tests of the windows have been carried out in the LHCD test facility at JET. All windows that were tested could operate at 500 kW for 10 s in a matched load. Two windows passed an endurance test at 250 kW for 20 s with the windows terminated in a short circuit. One window also passed this endurance test without active cooling. The results show that this type of window can be used in a new advanced launcher, as proposed for ITER, in which the output power from each klystron (P ≤ 500 kW) will be transmitted through one waveguide and one vacuum window. (author)

  20. Annual dynamics of daylight variability and contrast a simulation-based approach to quantifying visual effects in architecture

    CERN Document Server

    Rockcastle, Siobhan

    2013-01-01

    Daylight is a dynamic source of illumination in architectural space, creating diverse and ephemeral configurations of light and shadow within the built environment. Perceptual qualities of daylight, such as contrast and temporal variability, are essential to our understanding of both material and visual effects in architecture. Although spatial contrast and light variability are fundamental to the visual experience of architecture, architects still rely primarily on intuition to evaluate their designs because there are few metrics that address these factors. Through an analysis of contemporary

  1. Design methodology and criteria for daylight and thermal comfort in nearly-zero energy office buildings in Nordic climate

    DEFF Research Database (Denmark)

    Karlsen, Line Røseth

    The objective of this PhD thesis was to arrange for an integrated building design with respect to thermal comfort, daylighting and energy use, applicable for office buildings in Nordic climate. In order to achieve this, it is suggested that modelling of mean radiant temperature (MRT) should...... into the simulation tool IDA ICE. Furthermore, the control of solar shading is given attention, since it is a crucial link between the thermal and daylighting performance. The thesis presents results of an occupant survey with 46 subjects, which was carried out to investigate occupants’ preferences towards...

  2. The impact of changing solar screen rotation angle and its opening aspect ratios on Daylight Availability in residential desert buildings

    KAUST Repository

    Sherif, Ahmed H.

    2012-11-01

    In desert sunny clear-sky regions solar penetration can become excessive. This can cause non-uniform daylight distribution, glare and high solar heat gain, affecting both visual and thermal comfort. Shading devices, such as solar screens, were usually used to diffuse and prevent direct solar penetration into spaces. This paper investigates the impact of changing solar screen axial rotation angle and screen opening aspect ratio on daylighting performance in a typical residential living room space under the desert sunny clear-sky. The larger aim is to arrive at efficient solar screen designs that suit the different orientations.The study was divided into three consecutive phases. In phase one, the effect of the two parameters on Daylight Availability was tested. The solar screen was axially rotated by three different angles at 10° increments. Also, the aspect ratio of the screen opening in both horizontal and vertical directions was changed systematically. Simulation was conducted using the annual Daylight Dynamic Performance Metrics (DDPMs). In phase two, the Annual Daylight Glare Probability (DGP) metric was evaluated for the cases that were found adequate in phase one. In the third phase, the annual solar energy transmittance through the screen was calculated for the cases that achieved acceptable performance in the two previous phases in order to identify the more energy efficient screens.Solar screens with openings having horizontal aspect ratios were found to be the most effective, while those with vertical aspect ratios were achieved the lowest performance. In the North orientation, since almost all the cases that were tested in this research provided acceptable daylighting performance, the designer now have a variety of options to choose from. Preference should be given to screen openings of horizontal aspect ratios, especially the 12:1 and 18:1 (H:V) screens that achieved the best performance where 92% of the space was " daylit" in comparison with only 53

  3. Acoustic window planning for ultrasound acquisition.

    Science.gov (United States)

    Göbl, Rüdiger; Virga, Salvatore; Rackerseder, Julia; Frisch, Benjamin; Navab, Nassir; Hennersperger, Christoph

    2017-06-01

    Autonomous robotic ultrasound has recently gained considerable interest, especially for collaborative applications. Existing methods for acquisition trajectory planning are solely based on geometrical considerations, such as the pose of the transducer with respect to the patient surface. This work aims at establishing acoustic window planning to enable autonomous ultrasound acquisitions of anatomies with restricted acoustic windows, such as the liver or the heart. We propose a fully automatic approach for the planning of acquisition trajectories, which only requires information about the target region as well as existing tomographic imaging data, such as X-ray computed tomography. The framework integrates both geometrical and physics-based constraints to estimate the best ultrasound acquisition trajectories with respect to the available acoustic windows. We evaluate the developed method using virtual planning scenarios based on real patient data as well as for real robotic ultrasound acquisitions on a tissue-mimicking phantom. The proposed method yields superior image quality in comparison with a naive planning approach, while maintaining the necessary coverage of the target. We demonstrate that by taking image formation properties into account acquisition planning methods can outperform naive plannings. Furthermore, we show the need for such planning techniques, since naive approaches are not sufficient as they do not take the expected image quality into account.

  4. Exceptional and Spinorial Conformal Windows

    DEFF Research Database (Denmark)

    Mojaza, Matin; Pica, Claudio; Ryttov, Thomas

    2012-01-01

    We study the conformal window of gauge theories containing fermionic matter fields, where the gauge group is any of the exceptional groups with the fermions transforming according to the fundamental and adjoint representations and the orthogonal groups where the fermions transform according...

  5. Solar Heat Gain Coefficient (SHGC) | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  6. U-Factor (U-value) | Efficient Windows Collaborative

    Science.gov (United States)

    Foundry Foundry New Construction Windows Window Selection Tool Selection Process Design Guidance Installation Replacement Windows Window Selection Tool Assessing Options Selection Process Design Guidance Installation Understanding Windows Benefits Design Considerations Measuring Performance Performance Standards

  7. Polarization-independent transparency window induced by complementary graphene metasurfaces

    International Nuclear Information System (INIS)

    Lu, Wei Bing; Liu, Ji Long; Zhang, Jin; Wang, Jian; Liu, Zhen Guo

    2017-01-01

    A fourfold symmetric graphene-based complementary metasurface featuring a polarization-independent transparency window is proposed and numerically analysed in this paper. The unit cell of the metamaterial consists of a monolayer graphene perforated with a cross and four identical split-ring resonators deposited on a substrate. Our analysis shows that the transparency window can be interpreted as a plasmonic analogy of Autler–Townes splitting. The polarization independence is achieved due to the fourfold symmetry of graphene’s complementary structure. In addition, the frequency range of the transparency window can be dynamically tuned over a broad band by changing the chemical potential of graphene, and the width of the transparency window can also be controlled by changing the split-gap orientation. This work may lead to potential applications in many area, such as slow-light devices and optical sensing. (paper)

  8. Daylight for energy-saving lamps. Recognizing with lighting sources free of charge; Tageslicht vor Energiesparlampen. Kostenlos verfuegbare Lichtquellen einplanen

    Energy Technology Data Exchange (ETDEWEB)

    David, Holger

    2010-07-01

    With saving energy in the lighting, politics, economics and private households set on compact fluorescent lamps, so called energy-saving lamps. A more economical and pollution free alternative is the increased use of daylight, which is free of charge and felt more pleasant by humans.

  9. Switching From Conventional Photodynamic Therapy to Daylight Photodynamic Therapy For Actinic Keratoses: Systematic Review and Meta-analysis.

    Science.gov (United States)

    Tomás-Velázquez, A; Redondo, P

    2017-05-01

    Actinic keratosis is a precursor lesion to the most common nonmelanoma skin cancer. Conventional photodynamic therapy (PDT) has been shown to be effective, but the procedure is time-consuming, can be very painful, and requires infrastructure. These shortcomings led to the emergence of daylight PDT. To obtain a global estimate of efficacy, we undertook a systematic literature review and performed a meta-analysis of the available evidence on the efficacy and safety of daylight PDT as compared to conventional PDT in the treatment of actinic keratosis and/or field cancerization. The conclusion is that the difference in efficacy is clinically negligible (global estimate of the mean response rate difference, -3.69%; 95% CI, -6.54% to -0.84%). The adverse effects of daylight PDT are mild and localized (79% of patients report no discomfort), and patients report less pain (P<.001). Daylight PDT gives good to excellent cosmetic results in more than 90% of patients, and patient satisfaction is greater (P<.001). Copyright © 2016 AEDV. Publicado por Elsevier España, S.L.U. All rights reserved.

  10. Students' Perception of Daylight Illumination in the School Workshop as a Determinant for Effective Students' Task Performance in Workshop Practice

    Science.gov (United States)

    Amasuomo, Japo Oweikeye Morto; Alio, Abigail Ngozi

    2013-01-01

    The study investigated daylight illumination in the school workshop as a determinant for effective students' task performance in workshop practice. 183 NCE Technical students in 300 Level which comprised of 73 and 112 students from Federal Colleges of Education (Technical), Asaba and Omoku, Nigeria respectively during the 2008/2009 academic…

  11. *NEW* CRITICAL Windows Security patches

    CERN Multimedia

    2003-01-01

    On 3 October and 10 September 2003, Microsoft issued new CRITICAL security patches MS03-040 and MS03-039. They must be URGENTLY applied on ALL WINDOWS systems, which are not centrally managed for security patches. This includes Experiment computers, Home computers and Windows Portable and Desktop systems not running NICE. Details of the security holes and patches are at: MS03-039: http://cern.ch/it-div/news/hotfix-MS03-039.asp http://www.microsoft.com/technet/security/bulletin/MS03-039.asp MS03-040: http://cern.ch/it-div/news/hotfix-MS03-040.asp http://www.microsoft.com/technet/security/bulletin/MS03-040.asp

  12. Migration towards Windows 2000/XP

    International Nuclear Information System (INIS)

    Gal, J.

    2004-01-01

    The article deals with interesting technical solutions used in the project 'Migration towards Windows 2000/XP', which was introduced by the company AITEN, Plc for companies SE Plc, SEPS Plc and TEKO, Plc in the period 2002 and 2003. The contents of the project was migration of about 100 servers and more than 4 000 PC to the Windows 2000 and XP environs. The result of the project is a unified and documented system in the field of file, print and small application servers and PC. It has enabled to increase the system reliability and availability, to decrease the total costs for administration and operation and to establish the steady environs for users of the applications. (author)

  13. Lost sleep and cyberloafing: Evidence from the laboratory and a daylight saving time quasi-experiment.

    Science.gov (United States)

    Wagner, David T; Barnes, Christopher M; Lim, Vivien K G; Ferris, D Lance

    2012-09-01

    The Internet is a powerful tool that has changed the way people work. However, the ubiquity of the Internet has led to a new workplace threat to productivity-cyberloafing. Building on the ego depletion model of self-regulation, we examine how lost and low-quality sleep influence employee cyberloafing behaviors and how individual differences in conscientiousness moderate these effects. We also demonstrate that the shift to Daylight Saving Time (DST) results in a dramatic increase in cyberloafing behavior at the national level. We first tested the DST-cyberloafing relation through a national quasi-experiment, then directly tested the relation between sleep and cyberloafing in a closely controlled laboratory setting. We discuss the implications of our findings for theory, practice, and future research.

  14. Impact of daylight savings time on spontaneous pregnancy loss in in vitro fertilization patients.

    Science.gov (United States)

    Liu, Constance; Politch, Joseph A; Cullerton, Evan; Go, Kathryn; Pang, Samuel; Kuohung, Wendy

    2017-01-01

    Transition into daylight savings time (DST) has studied negative impacts on health, but little is known regarding impact on fertility. This retrospective cohort study evaluates DST impact on pregnancy and pregnancy loss rates in 1,654 autologous in vitro fertilization cycles (2009 to 2012). Study groups were identified based on the relationship of DST to embryo transfer. Pregnancy rates were similar in Spring and Fall (41.4%, 42.2%). Pregnancy loss rates were also comparable between Spring and Fall (15.5%, 17.1%), but rates of loss were significantly higher in Spring when DST occurred after embryo transfer (24.3%). Loss was marked in patients with a history of prior spontaneous pregnancy loss (60.5%).

  15. Daylighting and Cooling of Atrium Buildings in Warm Climates: Impact of the Top-Fenestration and Wall Mass Area.

    Science.gov (United States)

    Atif, Morad Rachid

    1992-01-01

    Sun-lighting and daylighting contribute greatly to the aesthetic value of an atrium. However, today's atria are often found either over-lit with extensive cooling loads, or under-lit requiring increased artificial lighting loads. The increase of the top-glazing area increases the cooling loads and decreases the lighting loads. The increase of the mass in the atrium walls decreases the maximum atrium temperature and the cooling loads. Furthermore, the mass distribution and its reflectance affect the lighting levels at the atrium floor. The purpose of this study is to investigate the simultaneous impact of the top-fenestration and the mass and reflectance of atrium walls on the cooling and daylighting performance of atria in warm climates. It attempts to determine the optimum top-fenestration for efficient daylighting and low cooling loads. The daylighting performance was evaluated through illumination measurements in physical models in a sky simulator. The cooling performance was evaluated using the software TRNSYS 13.1. Two types of top-fenestration were tested: horizontal and vertical south-facing, each with three alternate areas. The variations of the atrium walls included materials (standard frame and heavyweight concrete) and percentage and reflectance of the solid area. Two and four-story atria were considered, each with square and linear configuration. The performance was evaluated for three warm climates. The optimum top-fenestration for efficient daylighting was determined. The daylighting prediction algorithm was extended to include the effective reflectance of the atrium walls. The increase of mass in the atrium walls significantly decreased the atrium temperature range, the maximum atrium temperature, and the cooling loads. This impact decreased from horizontal to vertical south-facing top-glazing. The vertical south-facing top-glazing and, to a lesser degree, the reduction of the glazed atrium cover by 50% had more cooling benefits than increasing the

  16. Electrochromic Windows: Advanced Processing Technology

    Energy Technology Data Exchange (ETDEWEB)

    SAGE Electrochromics, Inc

    2006-12-13

    This project addresses the development of advanced fabrication capabilities for energy saving electrochromic (EC) windows. SAGE EC windows consist of an inorganic stack of thin films deposited onto a glass substrate. The window tint can be reversibly changed by the application of a low power dc voltage. This property can be used to modulate the amount of light and heat entering buildings (or vehicles) through the glazings. By judicious management of this so-called solar heat gain, it is possible to derive significant energy savings due to reductions in heating lighting, and air conditioning (HVAC). Several areas of SAGE’s production were targeted during this project to allow significant improvements to processing throughput, yield and overall quality of the processing, in an effort to reduce the cost and thereby improve the market penetration. First, the overall thin film process was optimized to allow a more robust set of operating points to be used, thereby maximizing the yield due to the thin film deposition themselves. Other significant efforts aimed at improving yield were relating to implementing new procedures and processes for the manufacturing process, to improve the quality of the substrate preparation, and the quality of the IGU fabrication. Furthermore, methods for reworking defective devices were developed, to enable devices which would otherwise be scrapped to be made into useful product. This involved the in-house development of some customized equipment. Finally, the improvements made during this project were validated to ensure that they did not impact the exceptional durability of the SageGlass® products. Given conservative estimates for cost and market penetration, energy savings due to EC windows in residences in the US are calculated to be of the order 0.026 quad (0.026×1015BTU/yr) by the year 2017.

  17. Linear gate with prescaled window

    Energy Technology Data Exchange (ETDEWEB)

    Koch, J; Bissem, H H; Krause, H; Scobel, W [Hamburg Univ. (Germany, F.R.). 1. Inst. fuer Experimentalphysik

    1978-07-15

    An electronic circuit is described that combines the features of a linear gate, a single channel analyzer and a prescaler. It allows selection of a pulse height region between two adjustable thresholds and scales the intensity of the spectrum within this window down by a factor 2sup(N) (0<=N<=9), whereas the complementary part of the spectrum is transmitted without being affected.

  18. Impact of coated windows on visual perception

    DEFF Research Database (Denmark)

    Johnsen, Kjeld; Dubois, Marie-Claude

    of brightness and colours in a space. Overall, the study shows that coated glazings may moderately affect the perception details, slightly affect the perception of glare from window and do not affect the perception of shadows on and around objects in the room. The results also suggest that the perception...... of brightness and other visual aspects such as sharpness, details, character, etc., seem to be a complex function of the intensity and colour of the transmitted light and is not solely and linearly dependent on the glazing light transmittance....

  19. Impact of daylight saving time on road traffic collision risk: a systematic review.

    Science.gov (United States)

    Carey, Rachel N; Sarma, Kiran M

    2017-07-02

    Bills have been put forward in the UK and Republic of Ireland proposing a move to Central European Time (CET). Proponents argue that such a change will have benefits for road safety, with daylight being shifted from the morning, when collision risk is lower, to the evening, when risk is higher. Studies examining the impact of daylight saving time (DST) on road traffic collision risk can help inform the debate on the potential road safety benefits of a move to CET. The objective of this systematic review was to examine the impact of DST on collision risk. Major electronic databases were searched, with no restrictions as to date of publication (the last search was performed in January 2017). Access to unpublished reports was requested through an international expert group. Studies that provided a quantitative analysis of the effect of DST on road safety-related outcomes were included. The primary outcomes of interest were road traffic collisions, injuries and fatalities. Twenty-four studies met the inclusion criteria. Seventeen examined the short-term impact of transitions around DST and 12 examined long-term effects. Findings from the short-term studies were inconsistent. The long-term findings suggested a positive effect of DST. However, this cannot be attributed solely to DST, as a range of road collision risk factors vary over time. The evidence from this review cannot support or refute the assertion that a permanent shift in light from morning to evening will have a road safety benefit. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  20. Analysis of impact of daylight time savings on energy use of buildings in Kuwait

    Energy Technology Data Exchange (ETDEWEB)

    Krarti, Moncef, E-mail: moncef.krarti@colorado.ed [CEAE Department, CB 428, University of Colorado, Boulder, CO 80309 (United States); Hajiah, Ali [Kuwait Institute for Scientific Research, Safat (Kuwait)

    2011-05-15

    In this paper, a detailed simulation-based analysis is conducted to assess the impact of adopting Daylight Saving Time (DST) on the electrical energy use and peak demand in Kuwait. The analysis focused on the impact of DST in the building sector since it represents 90% of electrical energy usage of Kuwait. The simulation results indicate that the adoption of DST has mixed impacts for Kuwait. While the commercial and the governmental sectors may benefit from the DST, the private residences and apartment buildings can see both their annual energy use and peak demand increase slightly by adopting DST. The overall impact of the DST implementation is rather minimal with a slight increase energy use of about 0.07% and a slight reduction in peak demand of 0.14% or about 12 MW based on 2005 electrical peak demand for Kuwait. - Research highlights: {yields} A detailed simulation-based analysis is conducted to assess the impact of adopting Daylight Saving Time (DST) on the electrical energy use and peak demand in Kuwait. {yields} The analysis focused on the impact of DST in the building sector since it represents 90% of electrical energy usage of Kuwait. {yields} It is found that while the commercial and the governmental building sectors may benefit from DST, the private residences and apartment buildings can see both their annual energy use and peak demand increase slightly by adopting DST. {yields} Since the residential sector represents the majority of the electrical load in Kuwait, DST adoption was found to cause slight increase in annual electrical energy use by about 0.07% and a slight reduction in electrical peak electrical demand by about 0.14%.

  1. Analysis of impact of daylight time savings on energy use of buildings in Kuwait

    International Nuclear Information System (INIS)

    Krarti, Moncef; Hajiah, Ali

    2011-01-01

    In this paper, a detailed simulation-based analysis is conducted to assess the impact of adopting Daylight Saving Time (DST) on the electrical energy use and peak demand in Kuwait. The analysis focused on the impact of DST in the building sector since it represents 90% of electrical energy usage of Kuwait. The simulation results indicate that the adoption of DST has mixed impacts for Kuwait. While the commercial and the governmental sectors may benefit from the DST, the private residences and apartment buildings can see both their annual energy use and peak demand increase slightly by adopting DST. The overall impact of the DST implementation is rather minimal with a slight increase energy use of about 0.07% and a slight reduction in peak demand of 0.14% or about 12 MW based on 2005 electrical peak demand for Kuwait. - Research highlights: → A detailed simulation-based analysis is conducted to assess the impact of adopting Daylight Saving Time (DST) on the electrical energy use and peak demand in Kuwait. → The analysis focused on the impact of DST in the building sector since it represents 90% of electrical energy usage of Kuwait. → It is found that while the commercial and the governmental building sectors may benefit from DST, the private residences and apartment buildings can see both their annual energy use and peak demand increase slightly by adopting DST. → Since the residential sector represents the majority of the electrical load in Kuwait, DST adoption was found to cause slight increase in annual electrical energy use by about 0.07% and a slight reduction in electrical peak electrical demand by about 0.14%.

  2. Travailler avec Windows 7 au CERN

    CERN Multimedia

    CERN. Geneva

    2011-01-01

    Vue d'ensemble des nouveaux concepts et des changements dans l'interface utilisateur survenus dans Windows 7 depuis les versions antérieures de Windows (XP ou Vista). Le plan de migration à Windows 7 sera aussi débattu.

  3. Travailler avec Windows 7 au CERN

    CERN Multimedia

    CERN. Geneva

    2012-01-01

    Vue d'ensemble des nouveaux concepts et des changements dans l'interface utilisateur survenus dans Windows 7 depuis les versions antérieures de Windows (XP ou Vista). Le plan de migration à Windows 7 sera aussi débattu.

  4. Tank 101-SY Window E core sample: Interpretation of results

    International Nuclear Information System (INIS)

    Reynolds, D.A.

    1993-02-01

    A full depth core sample was taken for tank 241-SY-101 in December 1991 during a time period called ''Window E.'' This was the second full depth core sample from this tank during the year. The core had two major portions that are known as the convective zone and the nonconvective zone. A crust was on the top of tank but as poorly sampled. The analysis of the Window E core sample stressed segment composite chemical analysis instead of segment by segment as in Window C. Adiabatic calorimetry on samples from both cores showed a slow self heating reaction above 150 degrees C on dried samples. The exothermic events were milder than similar synthetic samples. The chemical and physical properties complemented the information from Window C. The Window E material from the convective zone was more viscous than the Window C convective zone material. The nonconvective zone viscosities were similar for both cores. Heating and dilution tests were made to test mitigation concepts

  5. Tank 101-SY Window E core sample: Interpretation of results

    Energy Technology Data Exchange (ETDEWEB)

    Reynolds, D.A.

    1993-02-01

    A full depth core sample was taken for tank 241-SY-101 in December 1991 during a time period called ``Window E.`` This was the second full depth core sample from this tank during the year. The core had two major portions that are known as the convective zone and the nonconvective zone. A crust was on the top of tank but as poorly sampled. The analysis of the Window E core sample stressed segment composite chemical analysis instead of segment by segment as in Window C. Adiabatic calorimetry on samples from both cores showed a slow self heating reaction above 150{degrees}C on dried samples. The exothermic events were milder than similar synthetic samples. The chemical and physical properties complemented the information from Window C. The Window E material from the convective zone was more viscous than the Window C convective zone material. The nonconvective zone viscosities were similar for both cores. Heating and dilution tests were made to test mitigation concepts.

  6. Organic Light-Emitting Diode with Color Tunable between Bluish-White Daylight and Orange-White Dusk Hue

    Directory of Open Access Journals (Sweden)

    Shih-Yun Liao

    2014-01-01

    Full Text Available The varying color of sunlight diurnally exhibits an important effect on circadian rhythm of living organisms. The bluish-white daylight that is suitable for work shows a color temperature as high as 9,000 K, while the homey orange-white dusk hue is as low as 2,000 K. We demonstrate in this report the feasibility of using organic light-emitting diode (OLED technology to fabricate sunlight-style illumination with a very wide color temperature range. The color temperature can be tuned from 2,300 K to 9,300 K, for example, by changing the applied voltage from 3 to 11 V for the device composing red and yellow emitters in the first emissive layer and blue emitter in the second. Unlike the prior arts, the color-temperature span can be made much wider without any additional carrier modulation layer, which should enable a more cost effective fabrication. For example, the color-temperature span is 7,000 K for the above case, while it is 1,700 K upon the incorporation of a nanoscale hole modulation layer in between the two emissive layers. The reason why the present device can effectively regulate the shifting of recombination zone is because the first emissive layer itself possesses an effective hole modulation barrier of 0.2 eV. This also explains why the incorporation of an extra hole modulation layer with a 0.7 eV barrier did not help extend the desirable color-temperature span since excessive holes may be blocked.

  7. Rigid thin windows for vacuum applications

    Science.gov (United States)

    Meyer, Glenn Allyn; Ciarlo, Dino R.; Myers, Booth Richard; Chen, Hao-Lin; Wakalopulos, George

    1999-01-01

    A thin window that stands off atmospheric pressure is fabricated using photolithographic and wet chemical etching techniques and comprises at least two layers: an etch stop layer and a protective barrier layer. The window structure also comprises a series of support ribs running the width of the window. The windows are typically made of boron-doped silicon and silicon nitride and are useful in instruments such as electron beam guns and x-ray detectors. In an electron beam gun, the window does not impede the electrons and has demonstrated outstanding gun performance and survivability during the gun tube manufacturing process.

  8. Purged window apparatus utilizing heated purge gas

    Science.gov (United States)

    Ballard, Evan O.

    1984-01-01

    A purged window apparatus utilizing tangentially injected heated purge gases in the vicinity of electromagnetic radiation transmitting windows, and a tapered external mounting tube to accelerate these gases to provide a vortex flow on the window surface and a turbulent flow throughout the mounting tube. Use of this apparatus prevents backstreaming of gases under investigation which are flowing past the mouth of the mounting tube which would otherwise deposit on the windows. Lengthy spectroscopic investigations and analyses can thereby be performed without the necessity of interrupting the procedures in order to clean or replace contaminated windows.

  9. Professional Windows Embedded Compact 7

    CERN Document Server

    Phung, Samuel; Joubert, Thierry; Hall, Mike

    2011-01-01

    Learn to program an array of customized devices and solutions As a compact, highly efficient, scalable operating system, Windows Embedded Compact 7 (WEC7) is one of the best options for developing a new generation of network-enabled, media-rich, and service-oriented devices. This in-depth resource takes you through the benefits and capabilities of WEC7 so that you can start using this performance development platform today. Divided into several major sections, the book begins with an introduction and then moves on to coverage of OS design, application development, advanced application developm

  10. Windows 2012 Server network security securing your Windows network systems and infrastructure

    CERN Document Server

    Rountree, Derrick

    2013-01-01

    Windows 2012 Server Network Security provides the most in-depth guide to deploying and maintaining a secure Windows network. The book drills down into all the new features of Windows 2012 and provides practical, hands-on methods for securing your Windows systems networks, including: Secure remote access Network vulnerabilities and mitigations DHCP installations configuration MAC filtering DNS server security WINS installation configuration Securing wired and wireless connections Windows personal firewall

  11. Image annotation under X Windows

    Science.gov (United States)

    Pothier, Steven

    1991-08-01

    A mechanism for attaching graphic and overlay annotation to multiple bits/pixel imagery while providing levels of performance approaching that of native mode graphics systems is presented. This mechanism isolates programming complexity from the application programmer through software encapsulation under the X Window System. It ensures display accuracy throughout operations on the imagery and annotation including zooms, pans, and modifications of the annotation. Trade-offs that affect speed of display, consumption of memory, and system functionality are explored. The use of resource files to tune the display system is discussed. The mechanism makes use of an abstraction consisting of four parts; a graphics overlay, a dithered overlay, an image overly, and a physical display window. Data structures are maintained that retain the distinction between the four parts so that they can be modified independently, providing system flexibility. A unique technique for associating user color preferences with annotation is introduced. An interface that allows interactive modification of the mapping between image value and color is discussed. A procedure that provides for the colorization of imagery on 8-bit display systems using pixel dithering is explained. Finally, the application of annotation mechanisms to various applications is discussed.

  12. The plant-window system

    International Nuclear Information System (INIS)

    Wood, R.T.; Mullens, J.A.; Naser, J.A.

    1995-01-01

    Power plant data, and the information that can be derived from it, provide the link to the plant through which the operations, maintenance and engineering staff understand and manage plant performance. The increasing use of computer technology in the U.S. nuclear power industry has greatly expanded the capability to obtain, analyze, and present data about the plant to station personnel. However, it is necessary to transform the vast quantity of available data into clear, concise, and coherent information that can be readily accessed and used throughout the plant. This need can be met by an integrated computer workstation environment that provides the necessary information and software applications, in a manner that can be easily understood and used, to the proper users throughout the plant. As part of a Cooperative Research and Development Agreement with the Electric Power Research Institute, the Oak Ridge National Laboratory has developed functional requirements for a Plant-Wide Integrated Environment Distributed On Workstations (Plant-Window) System. The Plant-Window System (PWS) can serve the needs of operations, engineering, and maintenance personnel at nuclear power stations by providing integrated data and software applications (e.g., monitoring, analysis, diagnosis, and control applications) within a common environment. The PWS requirements identify functional capabilities and provide guidelines for standardized hardware, software, and display interfaces to define a flexible computer environment that permits a tailored implementation of workstation capabilities and facilitates future upgrades

  13. A randomized, multicentre study of directed daylight exposure times of 1½ vs. 2½ h in daylight-mediated photodynamic therapy with methyl aminolaevulinate in patients with multiple thin actinic keratoses of the face and scalp

    DEFF Research Database (Denmark)

    Wiegell, Stine; Fabricius, S; Stender, I M

    2011-01-01

    Actinic keratoses (AKs) are common dysplastic skin lesions that may differentiate into invasive squamous cell carcinomas. Although a superior cosmetic outcome of photodynamic therapy (PDT) is advantageous compared with equally effective treatments such as cryotherapy and curettage, the inconvenie......, the inconvenience of clinic attendance and discomfort during therapy are significant drawbacks. Daylight-mediated PDT could potentially reduce these and may serve as an alternative to conventional PDT....

  14. Daylighting analysis of rooflights through model measurements in the artificial sky

    Energy Technology Data Exchange (ETDEWEB)

    Filetoht, Levente I. [University of Technnology and Economics, Budapest, Hungary (Hungary)

    2000-07-01

    In investigating the daylighting of rooflights, it can be assumed that they are behaving as luminaires-having a major role in the lighting features of the interior space. Until now there is not enough precise information on these daylighting systems, and because of this, it is difficult to predict precisely the quality and quantity of illuminance and the light distribution in the interior. The exact behavior of the rooflights are complex and sophisticated. Their features are based on their geometry, reflectance and transmittance of their non-transparent, transparent and translucent surfaces. The effect of these features can not be predicted of calculated using the traditional mathematical methods. I am investigating roof-lighting systems taking into account the complex effects of their parts, using a completely new method based on a series of model measurements under artificial sky. Investigating the roof-light as a complex system which consist of relatively large surfaces and the effects of surfaces on other surfaces. Considering the different illuminance fields of the different types of roof-lighting systems. I will be able to determine the light distribution and efficiency of the system as well. The results of this research will lead to the development of a new computer software which is beyond the scope of this paper. [Spanish] Al investigar la iluminacion de luz de dia de luces de techo puede suponerse que se estan comportando como luminarias teniendo un papel principal en las caracteristicas de iluminacion del espacio interior. Hasta ahora no existe ninguna informacion precisa de estos sistemas de iluminacion de dia y a causa de ello es dificil predecir con precision la calidad y cantidad de iluminancia y la distribucion de la luz en el interior. El comportamiento exacto de las luces de techo es complejo y sofisticado. Sus caracteristicas estan basadas en su geometria, reflectancia y trasmitancia de sus superficies no transparentes, transparentes y

  15. Browning phenomenon of medieval stained glass windows.

    Science.gov (United States)

    Ferrand, Jessica; Rossano, Stéphanie; Loisel, Claudine; Trcera, Nicolas; van Hullebusch, Eric D; Bousta, Faisl; Pallot-Frossard, Isabelle

    2015-04-07

    In this work, three pieces of historical on-site glass windows dated from the 13th to 16th century and one archeological sample (8th century) showing Mn-rich brown spots at their surface or subsurface have been characterized by optical microscopy and Scanning Electron Microscopy coupled with Energy Dispersive X-ray spectroscopy. The oxidation state of Mn as well as the Mn environment in the alteration phase have been characterized by X-ray absorption spectroscopy at the Mn K-edge. Results show that the oxidation state of Mn and therefore the nature of the alteration phase varies according to the sample considered and is correlated with the extent of the brown alteration. The larger the brown areas the more oxidized the Mn. However, by contrast with literature, the samples presenting the more extended brown areas are not similar to pyrolusite and contain Mn mainly under a (+III) oxidation state.

  16. MS Windows domēna darbstaciju migrācija no MS Windows XP uz Windows Vista.

    OpenAIRE

    Tetere, Agate

    2009-01-01

    Kvalifikācijas darbā izpētīju darbstaciju migrācijas no Windows XP uz Windows Vista plusus un mīnusus. Darba gaitā tika veikti sekojoši uzdevumi: 1.Veikta Windows XP un Windows Vista darbstaciju instalācija, iestatījumu konfigurēšana un tika pārbaudīta sistēmas darbība 2.Veikta Windows Server 2003 un Windows Server 2008 instalācija, iestatījumu konfigurēšana un tika pārbaudīta sistēmas darbība 3.Izstrādāts migrācijas modelis 4.Veikta migrācijas optimizēšana 5.Veikta datu migrāc...

  17. Heat transport and solar transmission through a window system with low-emitting coatings

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, B; Ribbing, C G

    1977-12-01

    Heat transfer processes through a double-glazed window system are examined. Network calculations show the good insulation properties of a double-glazed window system including at least one low-emitting film. When the insolation is taken into consideration, absorption in the panes change the heat-balance and a heat-transfer coefficient can not be defined. The thermal and optical properties of windows with low-emitting metallic films are investigated. These windows depress the heat-losses but show a relatively low solar transmission. They are suitable for reducing intense sunlight during the summer period, together with good thermal insulation during periods with low insolation.

  18. A geostatistical analysis of IBTS data for age 2 North Sea haddock ( Melanogrammus aeglefinus ) considering daylight effects

    DEFF Research Database (Denmark)

    Wieland, Kai; Rivoirard, J.

    2001-01-01

    to ordinary kriging being most pronounced for years characterized by a high portion of night hauls and a low mean catch rate at night. This demonstrates that external drift kriging with a day/night indicator but preferably with time of day is capable of compensating successfully for daylight effects...... are included in the estimation without any correction for possible daylight effects. In the present study, ordinary kriging was used to correct for sampling irregularities and external drift kriging with a day/night indicator or a cosine function of time of day was applied to account additionally for diurnal...... differences in the catch rates. Only minor differences between the standard indices and the abundance estimates obtained by ordinary kriging were found. In contrast, the external drift kriging, particularly with time of day, yielded higher estimates of mean abundance for all years with the differences...

  19. Modeling Performance of an Airborne Infrared Sensor Used by a Man-in-the-Loop in Tactical Aircraft during Daylight Operations

    National Research Council Canada - National Science Library

    Harder, James

    1998-01-01

    .... The best monochromatic tactical aircraft displays are contrast limited during daylight operations and are able to reproduce only a fraction of the available dynamic range of current generation IR imaging sensors...

  20. Balancing the daylighting and energy performance of solar screens in residential desert buildings: Examination of screen axial rotation and opening aspect ratio

    KAUST Repository

    Sabry, Hanan; Sherif, Ahmed; Gadelhak, Mahmoud; Aly, Mohamed

    2014-01-01

    Solar screens are typically used to control solar access into building spaces. They proved their usefulness in improving the daylighting and energy performance of buildings in the hot arid desert environments which are endowed with abundance

  1. Assessing Thermal Comfort Due to a Ventilated Double Window

    Science.gov (United States)

    Carlos, Jorge S.; Corvacho, Helena

    2017-10-01

    Building design and its components are the result of a complex process, which should provide pleasant conditions to its inhabitants. Therefore, indoor acceptable comfort is influenced by the architectural design. ISO and ASHRAE standards define thermal comfort as the condition of mind that expresses satisfaction with the thermal environment. The energy demand for heating, beside the building’s physical properties, also depend on human behaviour, like opening or closing windows. Generally, windows are the weakest façade element concerning to thermal performance. A lower thermal resistance allows higher thermal conduction through it. When a window is very hot or cold, and the occupant is very close to it, it may result in thermal discomfort. The functionality of a ventilated double window introduces new physical considerations to a traditional window. In consequence, it is necessary to study the local effect on human comfort in function of the boundary conditions. Wind, solar availability, air temperature and therefore heating and indoor air quality conditions will affect the relationship between this passive system and the indoor environment. In the present paper, the influence of thermal performance and ventilation on human comfort resulting from the construction and geometry solutions is shown, helping to choose the best solution. The presented approach shows that in order to save energy it is possible to reduce the air changes of a room to the minimum, without compromising air quality, enhancing simultaneously local thermal performance and comfort. The results of the study on the effect of two parallel windows with a ventilated channel in the same fenestration on comfort conditions for several different room dimensions, are also presented. As the room dimensions’ rate changes so does the window to floor rate; therefore, under the same climatic conditions and same construction solution, different results are obtained.

  2. An adaptive sampling and windowing interrogation method in PIV

    Science.gov (United States)

    Theunissen, R.; Scarano, F.; Riethmuller, M. L.

    2007-01-01

    This study proposes a cross-correlation based PIV image interrogation algorithm that adapts the number of interrogation windows and their size to the image properties and to the flow conditions. The proposed methodology releases the constraint of uniform sampling rate (Cartesian mesh) and spatial resolution (uniform window size) commonly adopted in PIV interrogation. Especially in non-optimal experimental conditions where the flow seeding is inhomogeneous, this leads either to loss of robustness (too few particles per window) or measurement precision (too large or coarsely spaced interrogation windows). Two criteria are investigated, namely adaptation to the local signal content in the image and adaptation to local flow conditions. The implementation of the adaptive criteria within a recursive interrogation method is described. The location and size of the interrogation windows are locally adapted to the image signal (i.e., seeding density). Also the local window spacing (commonly set by the overlap factor) is put in relation with the spatial variation of the velocity field. The viability of the method is illustrated over two experimental cases where the limitation of a uniform interrogation approach appears clearly: a shock-wave-boundary layer interaction and an aircraft vortex wake. The examples show that the spatial sampling rate can be adapted to the actual flow features and that the interrogation window size can be arranged so as to follow the spatial distribution of seeding particle images and flow velocity fluctuations. In comparison with the uniform interrogation technique, the spatial resolution is locally enhanced while in poorly seeded regions the level of robustness of the analysis (signal-to-noise ratio) is kept almost constant.

  3. Mesothelial cell proliferation in the scala tympani: a reaction to the rupture of the round window membrane.

    Science.gov (United States)

    Sone, M

    1998-10-01

    The inner layer of the round window membrane is composed of mesothelial cells and this mesothelial cell layer extends to the scala tympani. This study describes the histopathologic findings of temporal bone analysis from a patient with bilateral perilymphatic fistula of the round window membrane. The left ear showed proliferation of mesothelial cells in the scala tympani of the basal turn adjoining the round window membrane. This cell proliferation is thought to be a reaction to the rupture of the round window membrane.

  4. Establishment and verification of solar radiation calculation model of glass daylighting roof in hot summer and warm winter zone in China

    OpenAIRE

    Zheng, Caidan; Wu, Peihao; Costanzo, Vincenzo; Wang, Yuchen; Yang, Xiaokun

    2017-01-01

    In this paper, solar heat gain through glass daylighting roof is deeply studied by theoretical calculation method, taking Guangzhou in the Hot Summer and Warm Winter (HSWW) zone as an example. The direct solar radiation is calculated by Bouguer formula whereas the diffuse solar radiation is calculated by Berlage formula, representing the basis for the calculation method of the solar radiation intensity through the glass daylighting roof. Through the establishment of solar radiation calculatio...

  5. Exposure to Non-Extreme Solar UV Daylight: Spectral Characterization, Effects on Skin and Photoprotection

    Directory of Open Access Journals (Sweden)

    Claire Marionnet

    2014-12-01

    Full Text Available The link between chronic sun exposure of human skin and harmful clinical consequences such as photo-aging and skin cancers is now indisputable. These effects are mostly due to ultraviolet (UV rays (UVA, 320–400 nm and UVB, 280–320 nm. The UVA/UVB ratio can vary with latitude, season, hour, meteorology and ozone layer, leading to different exposure conditions. Zenithal sun exposure (for example on a beach around noon under a clear sky can rapidly induce visible and well-characterized clinical consequences such as sunburn, predominantly induced by UVB. However, a limited part of the global population is exposed daily to such intense irradiance and until recently little attention has been paid to solar exposure that does not induce any short term clinical impact. This paper will review different studies on non-extreme daily UV exposures with: (1 the characterization and the definition of the standard UV daylight and its simulation in the laboratory; (2 description of the biological and clinical effects of such UV exposure in an in vitro reconstructed human skin model and in human skin in vivo, emphasizing the contribution of UVA rays and (3 analysis of photoprotection approaches dedicated to prevent the harmful impact of such UV exposure.

  6. Exposure to non-extreme solar UV daylight: spectral characterization, effects on skin and photoprotection.

    Science.gov (United States)

    Marionnet, Claire; Tricaud, Caroline; Bernerd, Françoise

    2014-12-23

    The link between chronic sun exposure of human skin and harmful clinical consequences such as photo-aging and skin cancers is now indisputable. These effects are mostly due to ultraviolet (UV) rays (UVA, 320-400 nm and UVB, 280-320 nm). The UVA/UVB ratio can vary with latitude, season, hour, meteorology and ozone layer, leading to different exposure conditions. Zenithal sun exposure (for example on a beach around noon under a clear sky) can rapidly induce visible and well-characterized clinical consequences such as sunburn, predominantly induced by UVB. However, a limited part of the global population is exposed daily to such intense irradiance and until recently little attention has been paid to solar exposure that does not induce any short term clinical impact. This paper will review different studies on non-extreme daily UV exposures with: (1) the characterization and the definition of the standard UV daylight and its simulation in the laboratory; (2) description of the biological and clinical effects of such UV exposure in an in vitro reconstructed human skin model and in human skin in vivo, emphasizing the contribution of UVA rays and (3) analysis of photoprotection approaches dedicated to prevent the harmful impact of such UV exposure.

  7. Effect of daylight saving time on lighting energy use: A literature review

    International Nuclear Information System (INIS)

    Aries, Myriam B.C.; Newsham, Guy R.

    2008-01-01

    The principal reason for introducing (and extending) daylight saving time (DST) was, and still is, projected energy savings, particularly for electric lighting. This paper presents a literature review concerning the effects of DST on energy use. Simple estimates suggest a reduction in national electricity use of around 0.5%, as a result of residential lighting reduction. Several studies have demonstrated effects of this size based on more complex simulations or on measured data. However, there are just as many studies that suggest no effect, and some studies suggest overall energy penalties, particularly if gasoline consumption is accounted for. There is general consensus that DST does contribute to an evening reduction in peak demand for electricity, though this may be offset by an increase in the morning. Nevertheless, the basic patterns of energy use, and the energy efficiency of buildings and equipment have changed since many of these studies were conducted. Therefore, we recommend that future energy policy decisions regarding changes to DST be preceded by high-quality research based on detailed analysis of prevailing energy use, and behaviours and systems that affect energy use. This would be timely, given the extension to DST underway in North America in 2007

  8. Robustness of circadian clocks to daylight fluctuations: hints from the picoeucaryote Ostreococcus tauri.

    Directory of Open Access Journals (Sweden)

    Quentin Thommen

    Full Text Available The development of systemic approaches in biology has put emphasis on identifying genetic modules whose behavior can be modeled accurately so as to gain insight into their structure and function. However, most gene circuits in a cell are under control of external signals and thus, quantitative agreement between experimental data and a mathematical model is difficult. Circadian biology has been one notable exception: quantitative models of the internal clock that orchestrates biological processes over the 24-hour diurnal cycle have been constructed for a few organisms, from cyanobacteria to plants and mammals. In most cases, a complex architecture with interlocked feedback loops has been evidenced. Here we present the first modeling results for the circadian clock of the green unicellular alga Ostreococcus tauri. Two plant-like clock genes have been shown to play a central role in the Ostreococcus clock. We find that their expression time profiles can be accurately reproduced by a minimal model of a two-gene transcriptional feedback loop. Remarkably, best adjustment of data recorded under light/dark alternation is obtained when assuming that the oscillator is not coupled to the diurnal cycle. This suggests that coupling to light is confined to specific time intervals and has no dynamical effect when the oscillator is entrained by the diurnal cycle. This intriguing property may reflect a strategy to minimize the impact of fluctuations in daylight intensity on the core circadian oscillator, a type of perturbation that has been rarely considered when assessing the robustness of circadian clocks.

  9. Low cost data acquisition module for evaluating the quantitative performance of daylight systems

    Energy Technology Data Exchange (ETDEWEB)

    Ciampini, F.; Scarazzato, P.S. [Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo, P.O. Box 6021, CEP 13083-852 Campinas (Brazil); Neves, A.A.R. [Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin, Departamento de Eletronica Quantica, P.O. Box 6165, 13083-970 Campinas (Brazil); Pereira, D.C.L.; Yamanaka, M.H. [Universidade de Sao Paulo, Faculdade de Arquitetura e Urbanismo, Departamento de Tecnologia da Arquitetura, Rua do Lago, 878 CEP 05508-080, Sao Paulo (Brazil)

    2007-09-15

    The search for efficient, auto-sustainable constructions that allows the user a contact with the outer environment has stimulated the development of advanced strategies, in various devices, for the exploitation of the daylight. A low cost data acquisition system was developed in this study, to observe the distribution of the natural light inside a prototype and to evaluate the quantitative performance for redirecting systems. The luminous sensor is a light dependent resistor, that responds to the illuminance with a reduction in the resistance when illuminated, through a log-log dependence. Calibration curves are set up to relate the change of resistance to absolute illuminance. It therefore provides a continuous investigation of the illuminance for various sampled points in the interior test space with a 0.03% digital error due to the 12-bit resolution. The final measured error of 5% is mainly due to the system calibration and resistance memory history. The circuit connects to a standard parallel port of any Personal Computer and supplies 64 analog inputs, one for each luminous sensor. The circuit can be easily modified to attend different quantities of analog inputs or communication ports. (author)

  10. Instant Windows PowerShell

    CERN Document Server

    Menon, Vinith

    2013-01-01

    Get to grips with a new technology, understand what it is and what it can do for you, and then get to work with the most important features and tasks. A practical, hands-on tutorial approach that explores the concepts of PowerShell in a friendly manner, taking an adhoc approach to each topic.If you are an administrator who is new to PowerShell or are looking to get a good grounding in these new features, this book is ideal for you. It's assumed that you will have some experience in PowerShell and Windows Server, as well being familiar with the PowerShell command-line.

  11. Editorial - Opening windows onto data

    Directory of Open Access Journals (Sweden)

    Judith Winters

    2012-05-01

    Full Text Available One of Internet Archaeology's strengths and 'unique selling points' not yet replicated by (many other e-journals, is that data is integrated into articles rather than being 'supplementary' or offered for download. The aim has always been for the narrative to be a wave driving readers towards the underlying data. Opening windows onto the data from within the text is one of the things I think the journal does best and is a feature used throughout Emma Durham's article 'Depicting the gods: metal figurines in Roman Britain'. Archaeological data does not speak for itself. It needs a narrative. It needs context. But by intermeshing data with interpretation, readers can dip into the data and start to explore it while reading the article, allowing a more immediate understanding of the bigger picture.

  12. TEMPERATURE FIELDS IN THE ZONE OF CONNECTION BETWEEN WINDOW AND BUILDING ENVELOPE

    OpenAIRE

    V. V. Ivanov; A. N. Butenko; L. V. Karaseva

    2011-01-01

    Problem statement. To determine additional heat losses through window opening slopes, it is ne-cessary to calculate temperature fields of a wall in the zone of connection between window and building envelope. Two types of building envelopes are considered: solid brick wall and two-layer-wall of bricks and fiber foam concrete block interlayered with air.Results. The results obtained show the influence of a window on the temperature field of wall opening. Different types of wall structures are ...

  13. Windows VPN Set Up | High-Performance Computing | NREL

    Science.gov (United States)

    Windows VPN Set Up Windows VPN Set Up To set up Windows for HPC VPN, here are the steps: Download your version of Windows. Note: We only support the the Endian Connect software when connecting to the a VPN connection to the HPC systems. Windows Version Connect App Windows 10

  14. Hybrid window layer for photovoltaic cells

    Science.gov (United States)

    Deng, Xunming

    2010-02-23

    A novel photovoltaic solar cell and method of making the same are disclosed. The solar cell includes: at least one absorber layer which could either be a lightly doped layer or an undoped layer, and at least a doped window-layers which comprise at least two sub-window-layers. The first sub-window-layer, which is next to the absorber-layer, is deposited to form desirable junction with the absorber-layer. The second sub-window-layer, which is next to the first sub-window-layer, but not in direct contact with the absorber-layer, is deposited in order to have transmission higher than the first-sub-window-layer.

  15. Energy optimised lighting in buildings with simultaneous improvement of quality of life by daylight utilisation and innovative lamps and ballast techniques; Energieoptimierte Beleuchtung bei gleichzeitiger Verbesserung der Lebensqualitaet durch Nutzung von Tageslicht und neuer Lampen- und Vorschalttechnik

    Energy Technology Data Exchange (ETDEWEB)

    Kaase, Heinrich; Aydinli, Sirri; Gramm, Stefan; Thiel, Stefan [Technische Universitaet Berlin, Fakultaet IV Elektrotechnik und Informatik, FG Lichttechnik, Berlin (Germany); De Boer, Jan; Erhorn, Hans [Fraunhofer-Institut fuer Bauphysik, Stuttgart (Germany); Kuhn, Tilman; Wienold, Jan [Fraunhofer-Institut fuer Solare Energiesysteme, Freiburg (Germany); Hillmann, Gustav; Korolkow, Margarethe [IBUS GmbH, Berlin (Germany); Piazena, Helmut [Universitaetsklinikum Charite, Berlin (Germany)

    2012-06-15

    The scientific and technical goals of this project were developed in five parts. The individual topics arising from current issues, they still have a generally applicable nature. The consortium has worked on the following subprojects: (1) Development of a measurement technique to determine energy and photometric key figures of daylight components with a round robin test with three institutes. (2) Implementation of a detailed evaluation and documentation process for daylighting of interior spaces in different climate zones. (3) For lighting control in private living areas a ''Power Line Carrier Communication'' system has been evaluated and the advantages of a wireless transmission system were identified. (4) In a home for elderly quantitative studies on the well-being, for the fulfillment of visual tasks and the capability of melatonin suppression at different scenarios of general lighting with two different color temperatures of lamps (''warm white'' with TCP = 3000 K and ''cold white daylight'' with TCP = 6500 K) and vertical illuminance at the eyes of the subjects between 100 lx and 700 lx were performed. (5) For two school buildings in Berlin, the final energy consumption of the existing lighting system, the reference building and a re-planning were determined. It became clear in both examples that the existing lighting system exceeds the permitted value (EnEV 2009) by far. A good redesign, however, can be significantly less than the maximum allowed value. These studies were accompanied by a one-year monitoring of energy consumption. A cross-sectional analysis of 48 schools with a total of 86 buildings shows a substantial need for renovation of school buildings that were built before 1990.

  16. Development of new concepts for escape windows to minimise cod catches in Norway lobster fisheries

    DEFF Research Database (Denmark)

    Madsen, Niels; Frandsen, Rikke; Holst, René

    2010-01-01

    Gear selectivity with regard to cod (Gadus morhua) needs to be improved in the Kattegat and Skagerrak Norway lobster (Nephrops norvegicus) fishery. One way to achieve this goal is to improve the selectivity of an escape window (henceforth window) in the gear. Our gear development focused particul......Gear selectivity with regard to cod (Gadus morhua) needs to be improved in the Kattegat and Skagerrak Norway lobster (Nephrops norvegicus) fishery. One way to achieve this goal is to improve the selectivity of an escape window (henceforth window) in the gear. Our gear development focused...... particularly on moving the window further back, gaining more stability in the codend to avoid loss of Norway lobster through the window, making a relatively narrow section where the window is located, and testing larger mesh sizes in the window. We designed a four panel sorting section—the sorting box......, but no improvement was observed for cod that came into contact with the window after reducing the distance from the window to the codline. The sorting box also showed a high reduction of flatfish and other roundfish species. The retention of Norway lobster above minimum landing size in the sorting box was higher...

  17. On the development of new SPMN diurnal video systems for daylight fireball monitoring

    Science.gov (United States)

    Madiedo, J. M.; Trigo-Rodríguez, J. M.; Castro-Tirado, A. J.

    2008-09-01

    Daylight fireball video monitoring High-sensitivity video devices are commonly used for the study of the activity of meteor streams during the night. These provide useful data for the determination, for instance, of radiant, orbital and photometric parameters ([1] to [7]). With this aim, during 2006 three automated video stations supported by Universidad de Huelva were set up in Andalusia within the framework of the SPanish Meteor Network (SPMN). These are endowed with 8-9 high sensitivity wide-field video cameras that achieve a meteor limiting magnitude of about +3. These stations have increased the coverage performed by the low-scan allsky CCD systems operated by the SPMN and, besides, achieve a time accuracy of about 0.01s for determining the appearance of meteor and fireball events. Despite of these nocturnal monitoring efforts, we realised the need of setting up stations for daylight fireball detection. Such effort was also motivated by the appearance of the two recent meteorite-dropping events of Villalbeto de la Peña [8,9] and Puerto Lápice [10]. Although the Villalbeto de la Peña event was casually videotaped, and photographed, no direct pictures or videos were obtained for the Puerto Lápice event. Consequently, in order to perform a continuous recording of daylight fireball events, we setup new automated systems based on CCD video cameras. However, the development of these video stations implies several issues with respect to nocturnal systems that must be properly solved in order to get an optimal operation. The first of these video stations, also supported by University of Huelva, has been setup in Sevilla (Andalusia) during May 2007. But, of course, fireball association is unequivocal only in those cases when two or more stations recorded the fireball, and when consequently the geocentric radiant is accurately determined. With this aim, a second diurnal video station is being setup in Andalusia in the facilities of Centro Internacional de Estudios y

  18. Analysis of surface contaminants on beryllium windows

    International Nuclear Information System (INIS)

    Gmur, N.F.

    1986-12-01

    It is known that various crystalline and liquid compounds form on the downstream surfaces of beryllium windows exposed to air. It is also known that the integrity of such windows may be compromised resulting in leaks through the window. The purpose of this report is to document the occurrences described as they pertain to the NSLS and to analyze, where possible, the various substances formed

  19. Adaptive Window Zero-Crossing-Based Instantaneous Frequency Estimation

    Directory of Open Access Journals (Sweden)

    Sekhar S Chandra

    2004-01-01

    Full Text Available We address the problem of estimating instantaneous frequency (IF of a real-valued constant amplitude time-varying sinusoid. Estimation of polynomial IF is formulated using the zero-crossings of the signal. We propose an algorithm to estimate nonpolynomial IF by local approximation using a low-order polynomial, over a short segment of the signal. This involves the choice of window length to minimize the mean square error (MSE. The optimal window length found by directly minimizing the MSE is a function of the higher-order derivatives of the IF which are not available a priori. However, an optimum solution is formulated using an adaptive window technique based on the concept of intersection of confidence intervals. The adaptive algorithm enables minimum MSE-IF (MMSE-IF estimation without requiring a priori information about the IF. Simulation results show that the adaptive window zero-crossing-based IF estimation method is superior to fixed window methods and is also better than adaptive spectrogram and adaptive Wigner-Ville distribution (WVD-based IF estimators for different signal-to-noise ratio (SNR.

  20. Early Observations on the Performance of Windows Azure

    Directory of Open Access Journals (Sweden)

    Zach Hill

    2011-01-01

    Full Text Available A significant open issue in cloud computing is the real performance of the infrastructure. Few, if any, cloud providers or technologies offer quantitative performance guarantees. Regardless of the potential advantages of the cloud in comparison to enterprise-deployed applications, cloud infrastructures may ultimately fail if deployed applications cannot predictably meet behavioral requirements. In this paper, we present the results of comprehensive performance experiments we conducted on Windows Azure from October 2009 to February 2010. In general, we have observed good performance of the Windows Azure mechanisms, although the average 10 min VM startup time must be accounted for in application design. We also present performance and reliability observations and analysis from our deployment of a large-scale scientific application hosted on Azure, called ModisAzure, that show unusual and sporadic VM execution slowdown of over 4× in some cases and affected up to 16% of task executions at times. In addition to a detailed performance evaluation of Windows Azure, we provide recommendations for potential users of Windows Azure based on these early observations. Although the discussion and analysis is tailored to scientific applications, the results are broadly applicable to the range of existing and future applications running in Windows Azure.