  1. Evaluation of myocardial and skeletal muscular involvement with thallium-201 myocardial emission computed tomography and whole body scintigraphy

    International Nuclear Information System (INIS)

    Yamamoto, Shuhei; Matsushima, Hideo; Sotobata, Iwao; Suzuki, Akio; Indo, Toshikatsu; Matsuoka, Yukihiko

    1986-01-01

    Thallium-201 (Tl-201) myocardial emission computed tomography and whole body scintigraphy were performed using a rotating gamma camera in 64 patients with neurologic disease and 14 normal subjects. Thallium-201 myocardial perfusion defects were seen in 40 % of the muscular involvement in 47 patients with muscular dystrophy (MD), in whom morphological abnormality of the heart was common. There was strong relationship between the degree of left ventricular perfusion defects and the degree of pulmonary uptake of Tl-201. Thallium-201 whole body scintigraphy showed homogeneous distribution of Tl-201 in the extremities in normal subjects, and perfusion defects in 73 % of the muscular lesions in MD patients. Muscular and skeletal lesions for MD appear to progress independently. Thallium-201 imaging seems to be of clinical value in assessing the muscular and skeletal lesions. (Namekawa, K.)

  2. Evaluation of skeletal muscular involvement in neuromuscular disorders with thallium-201 whole body scintigraphy

    International Nuclear Information System (INIS)

    Yamamoto, Shuhei; Sotobata, Iwao; Indo, Toshikatsu; Matsuoka, Yukihiko; Matsushima, Hideo; Suzuki, Akio; Abe, Tetsutaro; Sakuma, Sadayuki

    1986-01-01

    The extent as well as severity of pathologic changes of skeletal muscles were analyzed with thallium-201 whole body scintigraphy (WBS) in 29 cases of various types of neuromuscular diseases (18 cases of myogenic and 11 cases of neurogenic muscular diseases) and 14 cases of normal controls. After intravenous injection of 2 mCi of thallium-201 chloride, WBS was performed for 15 minutes using a gamma camera with twin-opposed large rectangular detectors. Counts at brachia, forearms, thighs, and calves were assessed after reconstruction of the scintigram of the whole body by taking the geometric mean of the anterior and posterior data. WBS showed uniform tracer activities in the 4 extremities in 12 cases among 14 controls. Laterality in distribution of counts of both legs and arms was noted in the remaining 2 controls. WBS revealed decrease of perfusion in the extremities with muscular atrophy and/or weakness in neuromuscular diseases. The overall diagnostic accuracy of WBS for evaluation of skeletal muscle involvement was 75 to 80 % except for the bilateral brachia for which it decreased to 65 %. All of the three cases of muscular dystrophy with pseudohypertrophy of the calves or thighs showed unequivocal decrease of perfusion of those regions in WBS. In conclusion, thallium-201 WBS was considered to be a useful clinical means in evaluating the extent and severity of muscular involvement of various types of neuromuscular disorders. (author)

  3. Dipyridamole thallium imaging

    International Nuclear Information System (INIS)

    Beer, S.G.; Heo, J.; Iskandrian, A.S.

    1991-01-01

    Dipyridamole cardiac imaging is a useful alternative to exercise stress testing in the evaluation of patients with ischemic heart disease. Intravenous dipyridamole has been approved recently for clinical use. Oral dipyridamole is widely available. The hemodynamic effects of dipyridamole include an increase in coronary blood flow in excess of the increase in myocardial oxygen consumption and cardiac output. The quality of the thallium images is better or similar to that of exercise thallium images. The optimal dose of intravenous dipyridamole is 0.56 mg/kg and the optimal oral dose is 300-375 mg, although higher doses may be necessary in some patients. The sensitivity and specificity of dipyridamole-thallium imaging, whether intravenous or oral, have been shown in a number of studies to be quite adequate and comparable to that achieved during exercise thallium imaging. Dipyridamole-thallium imaging has also been useful in identifying high-risk patients undergoing major elective vascular surgery. The relative merits of dipyridamole imaging versus exercise testing after acute myocardial infarction require further studies.83 references

  4. Thallium-201 imaging in children with osteogenic sarcoma

    International Nuclear Information System (INIS)

    Parker, M.K.; Koutsiofi, M.; Rossleigh, M.A.

    2003-01-01

    Full text: Thallium(Tl)-201 scintigraphy has been utilised in the imaging of a variety of tumours. This study evaluates its usefulness in children with osteogenic sarcoma. Five patients (3 male, 2 female) whose ages ranged from 11 to 15 years were investigated. Each child underwent a baseline 201 Tl study at diagnosis to determine the initial avidity of the tumour and a follow up study following chemotherapy, just prior to surgical excision, to assess tumour response to chemotherapy. This tumour response was confirmed by histopathological examination of the operative specimen. 201 Tl scintigraphy was undertaken 20 minutes following the intravenous administration of a weight adjusted dose of 201 Tl (minimum dose 20 MBq, adult dose 120 MBq). Whole body studies as well as planar images of the primary tumour were performed. All primary tumours were thallium avid on the baseline study. On the follow-up examination after therapy, a variety of patterns of uptake were seen and these correlated with the pathological findings. In one patient, complete loss of thallium accumulation following treatment corresponded to 100% tumour necrosis histologically. In another patient, persistent thallium uptake in the tumour following chemotherapy correlated with viable tumour cells on pathology and this patient died of his disease. In the other 3 patients, intermediate grade thallium appearances were demonstrated. In conclusion, 201 Tl scintigraphy is an excellent marker of osteogenic sarcoma and follow-up studies after chemotherapy accurately reflect residual tumour activity when correlated with histology. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  5. The evolution of whole-body imaging.

    LENUS (Irish Health Repository)

    Moran, Deirdre E

    2012-02-01

    This article reviews the evolution of whole-body imaging, discussing the history and development of radiography, nuclear medicine, computed tomography (CT), positron emission tomography (PET), combined PET-CT, and magnetic resonance imaging. The obstacles hindering progress toward whole-body imaging using each of these modalities, and the technical advances that were developed to overcome them, are reviewed. The effectiveness and the limitations of whole-body imaging with each of these techniques are also briefly discussed.

  6. Clinical evaluation of exercise thallium-201 whole body scintigraphy in ischemic heart disease

    International Nuclear Information System (INIS)

    Kaneko, Kenzo; Watanabe, Yoshihiko; Kondo, Takeshi

    1985-01-01

    To evaluate whole body distribution and kinetics of Thallium-201 at exercise and redistribution, whole body scintigraphy (WB-S) was performed on 12 normal subjects (N), 19 patients with angina pectoris (AP) and 18 patients with old myocardial infarction (MI). WB-S was obtained using a gamma camera OMEGA 500 and analized by ADAC System IV. We estimated the following parameters from WB-S; 1) %Distribution (%D): the ratio of whole body counts to organ counts 2) washout rate (WR) in each organ. %D of the heart in N, AP and MI was similar at rest and exercise. At exercise, %D of the lung and the liver decreased and %D of thighs increased remarkably than at rest. At supine exercise, the lung indicated high %D and thinghs indicated low %D compared with at upright exercise. WR of the heart in AP and MI was significantly lower than in N (p<0.005, p<0.01) and further decreased proportionally to the number of stenotic coronary arteries and related to the ischemic ST depression of exercise ECG. WR of the heart was not correlation with pressure rate product and this finding suggested that WR of the heart was not prescribed by the tolerance of exercise but related to coronary flow at exercise a certain degree. WR of the lung in MI was significantly higher (p<0.025) and WR of thighs in AP and MI was significantly lower (p<0.025, p<0.05) compared with N. (author)

  7. Comparison of whole-body-imaging methods

    International Nuclear Information System (INIS)

    Rollo, F.D.; Hoffer, P.

    1977-01-01

    Currently there are four different devices that have found clinical utility in whole-body imaging. These are the rectilinear scanner, the multicrystal whole-body scanner, the Anger-type camera with a whole-body-imaging table, and the tomoscanner. In this text, the basic theory of operation and a discussion of the advantages and disadvantages in whole-body imaging is presented for each device. When applicable, a comparative assessment of the various devices is also presented. As with all else in life, there is no simple answer to the question ''which total body imaging device is best.'' Institutions with a very heavy total-body-imaging load may prefer to use an already available dual-headed rectilinear scanner system for these studies, rather than invest in a new instrument. Institutions with moderate total-body-imaging loads may wish to invest in moving table or moving camera devices which make total body imaging more convenient but retain the basic flexibility of the camera. The large-field Anger camera with or without motion offers another flexible option to these institutions. The laboratory with a very heavy total body imaging load may select efficiency over flexibility, thereby freeing up other instruments for additional studies. Finally, reliability as well as availability and quality of local service must be considered. After all, design features of an instrument become irrelevant when it is broken down and awaiting repair

  8. Image fusion between whole body FDG PET images and whole body MRI images using a full-automatic mutual information-based multimodality image registration software

    International Nuclear Information System (INIS)

    Uchida, Yoshitaka; Nakano, Yoshitada; Fujibuchi, Toshiou; Isobe, Tomoko; Kazama, Toshiki; Ito, Hisao

    2006-01-01

    We attempted image fusion between whole body PET and whole body MRI of thirty patients using a full-automatic mutual information (MI) -based multimodality image registration software and evaluated accuracy of this method and impact of the coregistrated imaging on diagnostic accuracy. For 25 of 30 fused images in body area, translating gaps were within 6 mm in all axes and rotating gaps were within 2 degrees around all axes. In head and neck area, considerably much gaps caused by difference of head inclination at imaging occurred in 16 patients, however these gaps were able to decrease by fused separately. In 6 patients, diagnostic accuracy using PET/MRI fused images was superior compared by PET image alone. This work shows that whole body FDG PET images and whole body MRI images can be automatically fused using MI-based multimodality image registration software accurately and this technique can add useful information when evaluating FDG PET images. (author)

  9. Whole body imaging

    International Nuclear Information System (INIS)

    de Luca, P.C.; Stoddart, H.F.; Jeffries, D.

    1976-01-01

    A whole body imaging system rapidly forms a quality image of the bony structure, soft tissue or specific organs of a patient who has been injected with a suitable radioactive tracer chemical. A radiation detector head assembly includes a number of detector subassemblies, each having a lead collimator with tapered holes for admitting gamma radiation from a small area of the patient to a scintillation crystal that converts the gamma rays admitted by the collimator into visible or ultraviolet energy pulses. A photomultiplier converts these pulses into electrical pulses. A row of equally spaced detector subassemblies reciprocate within a nonreciprocating lead shield along the long axis of the array over a distance substantially equal to the separation between adjacent ones of the small areas. Associated electronic and electromechanical apparatus control the reciprocating motion and the longitudinal motion of the radiation detector head assembly, and process the photodetected signals to produce in a relatively short time a visible image of the radiant energy emanating from the whole body of the patient scanned

  10. Technetium-99m tetrofosmin imaging in thyroid diseases: comparison with Tc-99m-pertechnetate, thallium-201 and Tc-99m-methoxyisobutylisonitrile scans

    International Nuclear Information System (INIS)

    Klain, M.; Cuocolo, A.; Marzano, L.; Lombardi, G.; Salvatore, M.; Univ. di Napoli

    1996-01-01

    In this study, tetrofosmin whole-body scintigraphy was performed in 35 patients with evidence of thyroid diseases. All patients underwent laboratory evaluation of thyroid function as well as 99m Tc pertechnetate scan, thallium-201 99m Tc-methoxyisobutylisonitrile (MIBI) whole-body studies. Thyroid images were semi-quantitatively analysed by a 4-point score: 0=no significant uptake; 1=uptake increased but inferior to normal thyroid tissue; 2=uptake equal to normal thyroid tissue; 3=uptake superior to normal thyroid tissue. A total of 41 thyroid nodules were detected, of which 15 were goitre nodules, 13 adenomas and 13 malignant lesions. In goitre nodules, concordant results of tetrofosmin and pertechnetate uptake (score 1 or 0) were observed in the majority of lesions (87%). In function adenomas both tetrofosmin uptake and pertechnetate uptake were score 3. In non-function adenomas tetrofosmin uptake was score 3, while pertechnetate uptake was score 0. In six malignant lesions, tetrofosmin uptake was score 3, while pertechnetate uptake was score 0; in the other seven lesions, where a prevalence of goitre abnormalities was observed, results of tetrofosmin and pertechnetate uptake were similar (score 0 or 1). In (70%) patients with malignant nodules, whole-body tetrofosmin images showed increased abnormal uptake in a total of 28 extra-thyroid tumour sites, as subsequently confirmed by other techniques. When tetrofosmin images were compared to 201 Tl and 99m Tc-MIBI scans, concordant results were observed in all cases. In conclusion, tetrofosmin imaging may be particularly useful to characterize and stage patients with malignant thyroid nodules; it shows similar results to thallium but provides better image quality. Comparable findings were observed between tetrofosmin and MIBI studies. Thus, tetrofosmin may be an alternative to thallium and MIBI in the aforementioned patients. (orig.). With 4 figs., 3 tabs

  11. Pharmacokinetic and dosimetric characteristics of some thallium isotopes

    International Nuclear Information System (INIS)

    Tultaev, A.V.; Tarasenko, Yu.I.; Popov, V.I.; Korsunskij, V.N.

    1989-01-01

    Pharmacokinetics is studied, radiation doses to patients when using domestic thallium-201 chloride in diagnosis of the heart ischemic disease is estimated; contribution into the total dose of thallium-201 (1.5 %), thallium-201 (0.2 %) and lead-201 + lead-203 (0.05 %) radionuclide impurities is also determined. Internal doses were estimated for a heterogeneous phantom of a standard man; the calculations were carried out using a computer. Scanning of patients which were treated with radiopharmaceuticals to be diagnosed was carried out using a whole body counter and gamma-chamber. Large intestine, kidneys and thyroid are the critical organs when using thallium-201 chloride. The highest contribution into the dose to organs and the whole body from thallium-200 and thallium-202 impurities being contained in thallium-201, doesn't exceed 8.6 %. The contribution into the dose from lead-201 and lead-203 may be ignored. Doses from thallium-199 preparation per activity unit are ∼10 times less in comparison with those from thallium-201. 19 refs.; 1 fig.; 5 tabs

  12. Whole-body MR imaging of bone marrow

    International Nuclear Information System (INIS)

    Schmidt, G.P.; Schoenberg, S.O.; Reiser, M.F.; Baur-Melnyk, A.

    2005-01-01

    In clinical routine, multimodality algorithms, including X-ray, computed tomography, scintigraphy and MRI, are used in case of suspected bone marrow malignancy. Skeletal scintigraphy is widely used to asses metastatic disease to the bone, CT is the technique of choice to assess criteria of osseous destruction and bone stability. MRI is the only imaging technique that allows direct visualization of bone marrow and its components with high spatial resolution. The combination of unenhanced T1-weighted-spin echo- and turbo-STIR-sequences have shown to be most useful for the detection of bone marrow abnormalities and are able to discriminate benign from malignant bone marrow changes. Originally, whole-body MRI bone marrow screening was performed in sequential scanning techniques of five body levels with time consuming coil rearrangement and repositioning of the patient. The introduction of a rolling platform mounted on top of a conventional MRI examination table facilitated whole-body MR imaging and, with the use of fast gradient echo, T1-weighted and STIR-imaging techniques, for the first time allowed whole-body imaging within less than one hour. With the development of parallel imaging techniques (PAT) in combination with global matrix coil concepts, acquisition time could be reduced substantially without compromises in spatial resolution, enabling the implementation of more complex and flexible examination protocols. Whole-body MRI represents a new alternative to the stepwise multimodality concept for the detection of metastatic disease, multiple myeloma and lymphoma of the bone with high diagnostic accuracy

  13. Advanced CUBIC protocols for whole-brain and whole-body clearing and imaging.

    Science.gov (United States)

    Susaki, Etsuo A; Tainaka, Kazuki; Perrin, Dimitri; Yukinaga, Hiroko; Kuno, Akihiro; Ueda, Hiroki R

    2015-11-01

    Here we describe a protocol for advanced CUBIC (Clear, Unobstructed Brain/Body Imaging Cocktails and Computational analysis). The CUBIC protocol enables simple and efficient organ clearing, rapid imaging by light-sheet microscopy and quantitative imaging analysis of multiple samples. The organ or body is cleared by immersion for 1-14 d, with the exact time required dependent on the sample type and the experimental purposes. A single imaging set can be completed in 30-60 min. Image processing and analysis can take whole-brain neural activities at single-cell resolution using Arc-dVenus transgenic (Tg) mice. CUBIC informatics calculated the Venus signal subtraction, comparing different brains at a whole-organ scale. These protocols provide a platform for organism-level systems biology by comprehensively detecting cells in a whole organ or body.

  14. Automatic anatomy recognition in whole-body PET/CT images

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Huiqian [College of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China and Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Udupa, Jayaram K., E-mail: jay@mail.med.upenn.edu; Odhner, Dewey; Tong, Yubing; Torigian, Drew A. [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States); Zhao, Liming [Medical Image Processing Group Department of Radiology, University of Pennsylvania, Philadelphia, Pennsylvania 19104 and Research Center of Intelligent System and Robotics, Chongqing University of Posts and Telecommunications, Chongqing 400065 (China)

    2016-01-15

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  15. Automatic anatomy recognition in whole-body PET/CT images

    International Nuclear Information System (INIS)

    Wang, Huiqian; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.; Zhao, Liming

    2016-01-01

    Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., “Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images,” Med. Image Anal. 18, 752–771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process

  16. Whole-body intravoxel incoherent motion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Wurnig, Moritz C.; Eberhardt, Christian; Guggenberger, Roman; Boss, Andreas [University Hospital Zurich, Department of Radiology, Zurich (Switzerland); Luechinger, Roger [University and ETH Zurich, Institute of Biomedical Technology, Zurich (Switzerland)

    2015-07-15

    To investigate the technical feasibility of whole-body intravoxel incoherent motion (IVIM) imaging. Whole-body MR images of eight healthy volunteers were acquired at 3T using a spin-echo echo-planar imaging sequence with eight b-values. Coronal parametrical whole-body maps of diffusion (D), pseudodiffusion (D*), and the perfusion fraction (F{sub p}) were calculated. Image quality was rated qualitatively by two independent radiologists, and inter-reader reliability was tested with intra-class correlation coefficients (ICCs). Region of interest (ROI) analysis was performed in the brain, liver, kidney, and erector spinae muscle. Depiction of anatomic structures was rated as good on D maps and good to fair on D* and F{sub p} maps. Exemplary mean D (10{sup -3} mm{sup 2}/s), D* (10{sup -3} mm{sup 2}/s) and F{sub p} (%) values (± standard deviation) of the renal cortex were as follows: 1.7 ± 0.2; 15.6 ± 6.5; 20.9 ± 4.4. Inter-observer agreement was ''substantial'' to ''almost perfect'' (ICC = 0.80 - 0.92). The coefficient of variation of D* was significantly lower with the proposed algorithm compared to the conventional algorithm (p < 0.001), indicating higher stability. The proposed IVIM protocol allows computation of parametrical maps with good to fair image quality. Potential future clinical applications may include characterization of widespread disease such as metastatic tumours or inflammatory myopathies. (orig.)

  17. Thallium-201 infusion imaging

    International Nuclear Information System (INIS)

    Alazraki, N.; Kralios, A.; Wooten, W.W.

    1988-01-01

    To test the accuracy of Thallium-201 coronary artery infusion imaging of the earth during rapid changes in blood flow through a major coronary artery, the author performed a study in dogs correlating electromagnetic flow probe recordings with 201 Tl scintillation camera acquisitions. Hyperemic vascular response was produced experimentally in a major coronary artery by occlusion and release interventions which altered flow from baseline to zero during occlusion (20 seconds), followed by rapid flow increases approaching three times baseline immediately upon release of the occlusion. Flow returned to the baseline level within 60 seconds following release. Flow was also altered in a controlled fashion by other interventions. Recordings of Thallium uptake in the myocardium were displayed as a time histogram (counts per second squared vs time) which correlated very closely with electromagnetic flow probe recordings of flow (R=o.82-0.97). These experiments demonstrate a high degree of accuracy in Thallium infusion imaging to detect rapid changes in flow through a major coronary artery

  18. Effect of eating on thallium myocardial imaging

    International Nuclear Information System (INIS)

    Wilson, R.A.; Sullivan, P.J.; Okada, R.D.; Boucher, C.A.; Morris, C.; Pohost, G.M.; Strauss, H.W.

    1986-01-01

    To determine if eating between initial and delayed thallium images alters the appearance of the delayed thallium scan, a prospective study was performed; 184 subjects sent for routine thallium imaging were randomized into two groups, those who ate a meal high in carbohydrates between initial and delayed thallium myocardial images (n = 106), and those who fasted (n = 78). The 201 Tl images were interpreted in blinded fashion for global myocardial and pulmonary clearance of 201 Tl myocardial defects. The eating group had a significantly lower incidence of transient myocardial defects compared to the noneating group (7 percent vs 18 percent, respectively; p less than 0.05). The time between initial and delayed images and the incidence of exercise-induced ischemic ST-segment depression or pathologic Q waves on the electrocardiogram were not significantly different between the two groups. These data suggest that eating a high-carbohydrate meal between initial and delayed 201 Tl images causes increased 201 Tl myocardial clearance rates and may alter 201 Tl myocardial redistribution over time

  19. Thallium-201 stress imaging in hypertensive patients

    International Nuclear Information System (INIS)

    Schulman, D.S.; Francis, C.K.; Black, H.R.; Wackers, F.J.

    1987-01-01

    To assess the potential effect of hypertension on the results of thallium-201 stress imaging in patients with chest pain, 272 thallium-201 stress tests performed in 133 hypertensive patients and 139 normotensive patients over a 1-year period were reviewed. Normotensive and hypertensive patients were similar in age, gender distribution, prevalence of cardiac risk factors (tobacco smoking, hyperlipidemia, and diabetes mellitus), medications, and clinical symptoms of coronary disease. Electrocardiographic criteria for left ventricular hypertrophy were present in 16 hypertensive patients. Stepwise probability analysis was used to determine the likelihood of coronary artery disease for each patient. In patients with mid to high likelihood of coronary disease (greater than 25% probability), abnormal thallium-201 stress images were present in 54 of 60 (90%) hypertensive patients compared with 51 of 64 (80%) normotensive patients. However, in 73 patients with a low likelihood of coronary disease (less than or equal to 25% probability), abnormal thallium-201 stress images were present in 21 patients (29%) of the hypertensive group compared with only 5 of 75 (7%) of the normotensive patients (p less than 0.001). These findings suggest that in patients with a mid to high likelihood of coronary artery disease, coexistent hypertension does not affect the results of thallium-201 exercise stress testing. However, in patients with a low likelihood of coronary artery disease, abnormal thallium-201 stress images are obtained more frequently in hypertensive patients than in normotensive patients

  20. Whole-body imaging of the musculoskeletal system: the value of MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Gerwin P.; Reiser, Maximilian F.; Baur-Melnyk, Andrea [University Hospitals Munich/Grosshadern, LMU, Institute of Clinical Radiology, Munich (Germany)

    2007-12-15

    In clinical practice various modalities are used for whole-body imaging of the musculoskeletal system, including radiography, bone scintigraphy, computed tomography, magnetic resonance imaging (MRI), and positron emission tomography-computed tomography (PET-CT). Multislice CT is far more sensitive than radiographs in the assessment of trabecular and cortical bone destruction and allows for evaluation of fracture risk. The introduction of combined PET-CT scanners has markedly increased diagnostic accuracy for the detection of skeletal metastases compared with PET alone. The unique soft-tissue contrast of MRI enables for precise assessment of bone marrow infiltration and adjacent soft tissue structures so that alterations within the bone marrow may be detected before osseous destruction becomes apparent in CT or metabolic changes occur on bone scintigraphy or PET scan. Improvements in hard- and software, including parallel image acquisition acceleration, have made high resolution whole-body MRI clinically feasible. Whole-body MRI has successfully been applied for bone marrow screening of metastasis and systemic primary bone malignancies, like multiple myeloma. Furthermore, it has recently been proposed for the assessment of systemic bone diseases predisposing for malignancy (e.g., multiple cartilaginous exostoses) and muscle disease (e.g., muscle dystrophy). The following article gives an overview on state-of-the-art whole-body imaging of the musculoskeletal system and highlights present and potential future applications, especially in the field of whole-body MRI. (orig.)

  1. Study on the usefulness of whole body SPECT coronal image, MIP image in 67Ga scintigraphy

    International Nuclear Information System (INIS)

    Kawamura, Seiji

    2002-01-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with 67 Ga-citrate ( 67 Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  2. 5 years prognostic value of dipyridamole-thallium myocardial imaging

    International Nuclear Information System (INIS)

    Yang Yifeng; Qian Zhonghao; Jiang Changying

    1993-01-01

    A prognostic study of dipyridamole-thallium myocardial imaging was conducted with the use of logistic regression. Over a 5 years follow-up period, cardiac events occurred in 13 patients within the 41 patients tested, death in 5 and myocardial infarction in 8. The results of this study indicates that dipyridamole-thallium imaging has significant prognostic utility and that an abnormal scan increased the relative risk for the development of subsequent myocardial infarction or cardiac death (O.R. 18.54). The presence of transient multiple thallium defects further increased the risk of a cardiac event. In conclusion , intravenous dipyridamole thallium imaging is a potentially useful diagnostic test to determine the presence and severity of coronary diseases, and this noninvasive method is also beneficial for prognosis

  3. Whole body MR imaging in diabetes

    International Nuclear Information System (INIS)

    Weckbach, Sabine; Schoenberg, Stefan O.

    2009-01-01

    Diabetes mellitus is a major cardiovascular risk factor and one of the major causes for morbidity and mortality worldwide. Diabetic complications have not only major impact on the quality of life of diabetic patients, but are also potentially life-threatening. Therefore prevention, diagnosis and therapy of these long-term complications are of high importance. However, diagnosis of the variety of complications from diabetes mellitus remains a diagnostic challenge and usually several diagnostic steps are necessary to diagnose or exclude these complications. In the last years whole body magnetic resonance imaging (WB-MRI) including whole body magnetic resonance angiography (WB-MRA) has been introduced for cardiovascular imaging and is now increasingly applied in clinical routine for the workup of patients with cardiovascular disease and for cardiovascular screening. The article summarizes rationales for WB-MRI in diabetes mellitus, technical concepts of disease specific cardiovascular WB-MRI in diabetes mellitus and discusses potential clinical consequences.

  4. Clinical utility and problem of thallium myocardial imaging after coronary angioplasty

    International Nuclear Information System (INIS)

    Konishi, Tokuji; Tamai, Takuya; Nakamura, Mashio; Miyahara, Masatoshi; Isaka, Naoki; Nakano, Takeshi.

    1995-01-01

    The purpose of this study was twofold: (1) to assess the value and limits of stress thallium myocardial imaging in the diagnosis of reclosure after percutaneous transluminal coronary angioplasty (PTCA) and (2) to determine how myocardial viability, as determined on thallium imaging, influenced the therapeutic option. In study 1, 117 segments, which were treated with PTCA, were examined. Of 52 segments that showed thallium defects, 27 were treated with repeated PTCA. Of the other 25 segments, 12 were found to be reclosed. On the other hand, 65 other segments showed redistribution on thallium imaging, and 60 of these had no reclosure. The remaining 5 segments that were reclosed reflected no evidence of myocardial viability. These findings suggest that coronary arteriography may omitted when redistribution is seen on stress thallium imaging after PTCA. The population in Study 2 included 39 patients who were diagnosed as having myocardial necrosis on thallium imaging. In 22 of these patients, thallium findings ruled out coronary revascularization. One other patient did not undergo coronary revascularization because of technical problems. Thus, the remaining 16 patients were treated with coronary revascularization combined with bypass surgery for necrotic zones (n=10) or with PTCA for preserved collateral circulation (n=6). For necrotic zones evidenced on thallium imaging, factors other than necrosis were considered in determining coronary revascularization. (N.K.)

  5. Whole-body magnetic resonance imaging in axial spondyloarthritis

    DEFF Research Database (Denmark)

    Krabbe, Simon; Østergaard, Mikkel; Eshed, Iris

    2018-01-01

    Objective. To investigate whether adalimumab (ADA) reduces whole-body (WB-) magnetic resonance imaging (MRI) indices for inflammation in the entheses, peripheral joints, sacroiliac joints, spine, and the entire body in patients with axial spondyloarthritis (axSpA). Methods. An investigator-initia...

  6. Whole-body magnetic resonance imaging in children: state of the art

    Directory of Open Access Journals (Sweden)

    Sara Reis Teixeira

    2015-04-01

    Full Text Available Whole-body imaging in children was classically performed with radiography, positron-emission tomography, either combined or not with computed tomography, the latter with the disadvantage of exposure to ionizing radiation. Whole-body magnetic resonance imaging (MRI, in association with the recently developed metabolic and functional techniques such as diffusion-weighted imaging, has brought the advantage of a comprehensive evaluation of pediatric patients without the risks inherent to ionizing radiation usually present in other conventional imaging methods. It is a rapid and sensitive method, particularly in pediatrics, for detecting and monitoring multifocal lesions in the body as a whole. In pediatrics, it is utilized for both oncologic and non-oncologic indications such as screening and diagnosis of tumors in patients with genetic syndromes, evaluation of disease extent and staging, evaluation of therapeutic response and post-therapy follow-up, evaluation of non neoplastic diseases such as multifocal osteomyelitis, vascular malformations and syndromes affecting multiple regions of the body. The present review was aimed at describing the major indications of whole-body MRI in pediatrics added of technical considerations.

  7. Study on the usefulness of whole body SPECT coronal image, MIP image in {sup 67}Ga scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kawamura, Seiji [Kurume Univ., Fukuoka (Japan). Hospital; Ishibashi, Masatoshi; Kurata, Seiji; Morita, Seiichirou; Hayabuchi, Naofumi [Kurume Univ., Fukuoka (Japan). School of Medicine; Fukushima, Shigehiro [Kyushu Inst. of Design, Fukuoka (Japan). Graduate School of Auditory and Visual Communication Sciences; Umezaki, Noriyoshi [Daiichi Coll. of Pharmaceutical Sciences, Fukuoka (Japan)

    2002-05-01

    In this study, we examined the usefulness of whole body coronal images and whole body cine display MIP images (CMIP) upon which image processing was carried out after whole body SPECT in comparison to the usefulness of whole body images (WB/SC) compensated by scattered radiation in tumor/inflammation scintigraphy with {sup 67}Ga-citrate ({sup 67}Ga). Image interpretation was performed for the 120 patients with confirmed diagnoses, and the accuracy of their diagnoses was studied by three nuclear medical physicians and two clinical radiological technologists by means of sensitivity, specificity and ROC analysis. The resultant data show that sensitivity, specificity, accuracy and the area under the ROC curve Az in the WB/SC were approximately 65%, 86%, 74% and 0.724, respectively, whereas sensitivity, specificity, accuracy and Az of the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method were approximately 93%, 95%, 94% and 0.860, respectively. Furthermore, coronal images reconstructed by the OS-EM method tended to be superior to those produced by the FBP method in both diagnostic accuracy and ROC analysis. In conclusion, the image reading system in which CMIP is combined with whole body coronal images reconstructed by the OS-EM method was shown to be superior in diagnostic accuracy and ROC analysis. Our data suggest that whole body SPECT is an excellent technique as an alternative to WB/SC. (author)

  8. Thallium reinjection after stress-redistribution imaging. Does 24-hour delayed imaging after reinjection enhance detection of viable myocardium

    International Nuclear Information System (INIS)

    Dilsizian, V.; Smeltzer, W.R.; Freedman, N.M.; Dextras, R.; Bonow, R.O.

    1991-01-01

    Thallium reinjection immediately after conventional stress-redistribution imaging improves the detection of viable myocardium, as many myocardial regions with apparently 'irreversible' thallium defects on standard 3-4-hour redistribution images manifest enhanced thallium uptake after reinjection. Because the 10-minute period between reinjection and imaging may be too short, the present study was designed to determine whether 24-hour imaging after thallium reinjection provides additional information regarding myocardial viability beyond that obtained by imaging shortly after reinjection. We studied 50 patients with chronic stable coronary artery disease undergoing exercise thallium tomography, radionuclide angiography, and coronary arteriography. Immediately after the 3-4-hour redistribution images were obtained, 1 mCi thallium was injected at rest, and images were reacquired at 10 minutes and 24 hours after reinjection. The stress, redistribution, reinjection, and 24-hour images were then analyzed qualitatively and quantitatively. Of the 127 abnormal myocardial regions on the stress images, 55 had persistent defects on redistribution images by qualitative analysis, of which 25 (45%) demonstrated improved thallium uptake after reinjection. At the 24-hour study, 23 of the 25 regions (92%) with previously improved thallium uptake by reinjection showed no further improvement. Similarly, of the 30 regions determined to have irreversible defects after reinjection, 29 (97%) remained irreversible on 24-hour images. These findings were confirmed by the quantitative analysis. The mean normalized thallium activity in regions with enhanced thallium activity after reinjection increased from 57 +/- 13% on redistribution studies to 70 +/- 14% after reinjection but did not change at 24 hours (71 +/- 14%)

  9. Prognostic implications of normal exercise thallium 201 images

    International Nuclear Information System (INIS)

    Wahl, J.M.; Hakki, A.H.; Iskandrian, A.S.

    1985-01-01

    A study was made of 455 patients (mean age, 51 years) in whom exercise thallium 201 scintigrams performed for suspected coronary artery disease were normal. Of those, 322 (71%) had typical or atypical angina pectoris and 68% achieved 85% or more maximal predicted heart rate. The exercise ECGs were abnormal in 68 patients (15%), normal in 229 (50%), and inconclusive in 158 (35%). Ventricular arrhythmias occurred during exercise in 194 patients (43%). After a mean follow-up period of 14 months, four patients had had cardiac events, sudden cardiac death in one and nonfatal myocardial infarctions in three. None of the four patients had abnormal exercise ECGs. Two had typical and two had atypical angina pectoris. Normal exercise thallium 201 images identify patients at a low risk for future cardiac events (0.8% per year), patients with abnormal exercise ECGs but normal thallium images have good prognoses, and exercise thallium 201 imaging is a better prognostic predictor than treadmill exercise testing alone, because of the high incidence of inconclusive exercise ECGs and the good prognosis in patients with abnormal exercise ECGs

  10. Whole Body Magnetic Resonance Imaging in the Diagnosis of Parsonage Turner Syndrome

    International Nuclear Information System (INIS)

    Ryan, M.; Twair, A.; Nelson, E.; Brennan, D.; Eustace, S.

    2004-01-01

    Purpose: To describe magnetic resonance imaging (MRI) findings in patients with suspected Parsonage Turner syndrome and to emphasize the value of an additional whole body MR scan to improve specificity of this diagnosis. Material and Methods: Three patients with proven Parsonage Turner syndrome referred for conventional MRI of the shoulder girdle and additional whole body turboSTIR MRI were included for study. Results: In each case, imaging revealed edema in the muscles of the shoulder girdle. Whole body turboSTIR MRI scan confirmed localized unilateral changes in each case improving specificity and confidence in the diagnosis of Parsonage Turner syndrome in each case. Conclusion: Whole body turboSTIR MR imaging is a useful diagnostic tool in the evaluation of patients with suspected Parsonage Turner syndrome. Inclusion of the brain, neck, brachial plexus, and extremity musculature at whole body imaging allows differentiation from polymyositis and elimination of additional causes of shoulder girdle pain and weakness including gross lesions in the brain, neck, and brachial plexus by a single non-invasive study

  11. Preoperative evaluation of cardiac risk using dobutamine-thallium imaging in vascular surgery

    International Nuclear Information System (INIS)

    Zellner, J.L.; Elliott, B.M.; Robison, J.G.; Hendrix, G.H.; Spicer, K.M.

    1990-01-01

    Coronary artery disease is frequently present in patients undergoing evaluation for reconstructive peripheral vascular surgery. Dobutamine-thallium imaging has been shown to be a reliable and sensitive noninvasive method for the detection of significant coronary artery disease. Eighty-seven candidates for vascular reconstruction underwent dobutamine-thallium imaging. Forty-eight patients had an abnormal dobutamine-thallium scan. Twenty-two patients had infarct only, while 26 had reversible ischemia demonstrated on dobutamine-thallium imaging. Fourteen of 26 patients with reversible ischemia underwent cardiac catheterization and 11 showed significant coronary artery disease. Seven patients underwent preoperative coronary bypass grafting or angioplasty. There were no postoperative myocardial events in this group. Three patients were denied surgery on the basis of unreconstructible coronary artery disease, and one patient refused further intervention. Ten patients with reversible myocardial ischemia on dobutamine-thallium imaging underwent vascular surgical reconstruction without coronary revascularization and suffered a 40% incidence of postoperative myocardial ischemic events. Five patients were denied surgery because of presumed significant coronary artery disease on the basis of the dobutamine-thallium imaging and clinical evaluation alone. Thirty-nine patients with normal dobutamine-thallium scans underwent vascular reconstructive surgery with a 5% incidence of postoperative myocardial ischemia. Dobutamine-thallium imaging is a sensitive and reliable screening method which identifies those patients with coronary artery disease who are at high risk for perioperative myocardial ischemia following peripheral vascular surgery

  12. Thallium 201 scintigraphy of the myocardium. A bibliographical survey for image optimisation

    International Nuclear Information System (INIS)

    Chatelier, Luc.

    1979-01-01

    At the request of a Nuclear Medicine Service we compiled a review of the literature on thallium 201 myocardium scintigraphy in order to define the optimum parameters for image acquisition; included also are the bibliograhical references of studies on the sensitivities, specificities and accuracies of this technique as compared with electrocardiography in the diagnosis and evaluation of ischemic heart diseases. This examination seems to have a part to play at all stages in the evaluation of ischemic heart diseases, whether for the detection (ischemia) emergency handling (thrombosis) or post-surgical checking (permeability of an aorto-coronary transplant) of these diseases, the great frequency and gravity of which have no longer to be proved. This study covers the whole period since thallium scintigraphy began (1970) until June 1978. Thallium seems to have a great future in cardiology and may be even in other fields since its use is quoted (in only a few publications as yet) for brain, kidney and pancreas scintigraphy [fr

  13. Whole-body magnetic resonance imaging in inflammatory arthritis

    DEFF Research Database (Denmark)

    Østergaard, Mikkel; Eshed, Iris; Althoff, Christian E.

    2017-01-01

    Objective: Whole-body magnetic resonance imaging (WB-MRI) is a relatively new technique that can enable assessment of the overall inflammatory status of people with arthritis, but standards for image acquisition, definitions of key pathologies, and a quantification system are required. Our aim...... was to perform a systematic literature review (SLR) and to develop consensus definitions of key pathologies, anatomical locations for assessment, a set of MRI sequences and imaging planes for the different body regions, and a preliminary scoring system for WB-MRI in inflammatory arthritis. Methods: An SLR...

  14. Thallium-201 myocardial imaging in the detection of coronary artery disease

    International Nuclear Information System (INIS)

    McKillop, J.H.; Murray, R.G.; Turner, J.G.; Gray, H.W.; Bessent, R.G.; Lorimer, A.R.; Greig, W.R.

    1978-01-01

    Thallium-201 myocardial imaging can detect abnormalities of myocardial perfusion. Visual interpretation of the images is complicated by some inhomogeneity of tracer uptake normally present. Using a quantitative approach we have established the regional variation of Thallium-201 uptake present in 23 normal controls and applied the same technique to 49 patients who had undergone selective coronary arteriography with left ventriculography because of chest pain. Half of the patients with significant coronary artery disease had abnormal rest Thallium-201 images, usually corresponding to areas of abnormal wall motion at ventriculography. Stress Thallium-201 images were abnormal in over 90% of patients with coronary artery disease. The stress image abnormalities and the arteriographic lesions correlated well in most patients with single and double vessel disease but in triple vessel disease the correspondence between the two studies was poor. Two of a group of patients with normal coronary arteriograms had abnormal Thallium-201 images due to other myocardial pathology. Our technique was highly sensitive in the non-invasive detection of significant coronary artery disease in a group of patients with chest pain. A small number of positive studies were also encountered due to other myocardial disorders. (author)

  15. Direct molecular analysis of whole-body animal tissue sections by MALDI imaging mass spectrometry.

    Science.gov (United States)

    Reyzer, Michelle L; Chaurand, Pierre; Angel, Peggi M; Caprioli, Richard M

    2010-01-01

    The determination of the localization of various compounds in a whole animal is valuable for many applications, including pharmaceutical absorption, distribution, metabolism, and excretion (ADME) studies and biomarker discovery. Imaging mass spectrometry is a powerful tool for localizing compounds of biological interest with molecular specificity and relatively high resolution. Utilizing imaging mass spectrometry for whole-body animal sections offers considerable analytical advantages compared to traditional methods, such as whole-body autoradiography, but the experiment is not straightforward. This chapter addresses the advantages and unique challenges that the application of imaging mass spectrometry to whole-body animal sections entails, including discussions of sample preparation, matrix application, signal normalization, and image generation. Lipid and protein images obtained from whole-body tissue sections of mouse pups are presented along with detailed protocols for the experiments.

  16. Whole-body and multispectral photoacoustic imaging of adult zebrafish

    Science.gov (United States)

    Huang, Na; Xi, Lei

    2016-10-01

    Zebrafish is a top vertebrate model to study developmental biology and genetics, and it is becoming increasingly popular for studying human diseases due to its high genome similarity to that of humans and the optical transparency in embryonic stages. However, it becomes difficult for pure optical imaging techniques to volumetric visualize the internal organs and structures of wild-type zebrafish in juvenile and adult stages with excellent resolution and penetration depth. Even with the establishment of mutant lines which remain transparent over the life cycle, it is still a challenge for pure optical imaging modalities to image the whole body of adult zebrafish with micro-scale resolution. However, the method called photoacoustic imaging that combines all the advantages of the optical imaging and ultrasonic imaging provides a new way to image the whole body of the zebrafish. In this work, we developed a non-invasive photoacoustic imaging system with optimized near-infrared illumination and cylindrical scanning to image the zebrafish. The lateral and axial resolution yield to 80 μm and 600 μm, respectively. Multispectral strategy with wavelengths from 690 nm to 930 nm was employed to image various organs inside the zebrafish. From the reconstructed images, most major organs and structures inside the body can be precisely imaged. Quantitative and statistical analysis of absorption for organs under illumination with different wavelengths were carried out.

  17. Serial Myocardial Imaging after a Single Dose of Thallium-201

    Directory of Open Access Journals (Sweden)

    Takahiko Kamata

    2014-10-01

    Full Text Available Although thallium-201 exercise scintigraphy has been established for the detection of myocardial ischemia and viability, little is known regarding the myocardial thallium-201 kinetics during angioplasty. Herein, we report a 77-year old man with angina pectoris, in whom serial myocardial imaging after a single dose of thallium-201 was helpful in identifying not only the culprit lesion and myocardial viability, but also the dynamic changes in myocardial perfusion during angioplasty. Thallium-201 images after exercise showed a perfusion defect in the inferior wall, with a trivial redistribution 3 hours after the exercise and a marked improvement 24 hours later. Coronary angiography, performed 27 hours after exercise scintigraphy, showed severe stenosis in the right coronary artery. Guidewire crossing of the lesion interrupted the antegrade flow, which was restored after balloon dilation and stent implantation. Thallium-201 images, 2 hours after angioplasty (i.e., 30 hours after exercise, showed a decreased tracer uptake in the inferior wall, which improved the next day (i.e., 48 hours after exercise. Cardiac biomarkers were negative in the clinical course.

  18. [Application of GVF snake model in segmentation of whole body bone SPECT image].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2008-02-01

    Limited by the imaging principle of whole body bone SPECT image, the gray value of bladder area is quite high, which affects the image's brightness, contrast and readability. In the meantime, the similarity between bladder area and focus makes it difficult for some images to be segmented automatically. In this paper, an improved Snake model, GVF Snake, is adopted to automatically segment bladder area, preparing for further processing of whole body bone SPECT images.

  19. Comparison of exercise electrocardiography and quantitative thallium imaging for one-vessel coronary artery disease

    International Nuclear Information System (INIS)

    Kaul, S.; Kiess, M.; Liu, P.; Guiney, T.E.; Pohost, G.M.; Okada, R.D.; Boucher, C.A.

    1985-01-01

    The relative value of exercise electrocardiography and computer analyzed thallium-201 imaging was compared in 124 patients with 1-vessel coronary artery disease (CAD). Of these, 78 had left anterior descending (LAD), 32 right and 14 left circumflex (LC) CAD. In patients with no previous myocardial infarction (MI), thallium imaging was more sensitive than the electrocardiogram (78% vs 64%, p less than 0.01), but in patients with previous MI, sensitivity was similar. Further, thallium imaging was more sensitive only in LAD and LC disease. Redistribution was compared with ST-segment depression as a marker of ischemia. Only in patients with prior MI (76% vs 44%, p less than 0.01) and only in LC and right CAD did redistribution occur more often than ST depression. Thallium imaging was more accurate in localizing stenoses than the electrocardiogram (p less than 0.001), but did not always correctly predict coronary anatomy. Septal thallium defects were associated with LAD disease in 84%, inferior defects with right CAD in 40% and posterolateral lesion defects with LC CAD in 22%. The results indicate the overall superiority of thallium imaging in 1-vessel CAD compared with exercise electrocardiography; however, there is a wide spectrum of extent and location of perfusion defects associated with each coronary artery. Thallium imaging complements coronary angiography by demonstrating the functional impact of CAD on myocardial perfusion

  20. Optimized workflow and imaging protocols for whole-body oncologic PET/MRI.

    Science.gov (United States)

    Ishii, Shirou; Hara, Takamitsu; Nanbu, Takeyuki; Suenaga, Hiroki; Sugawara, Shigeyasu; Kuroiwa, Daichi; Sekino, Hirofumi; Miyajima, Masayuki; Kubo, Hitoshi; Oriuchi, Noboru; Ito, Hiroshi

    2016-11-01

    Although PET/MRI has the advantages of a simultaneous acquisition of PET and MRI, high soft-tissue contrast of the MRI images, and reduction of radiation exposure, its low profitability and long acquisition time are significant problems in clinical settings. Thus, MRI protocols that meet oncological purposes need to be used in order to reduce examination time while securing detectability. Currently, half-Fourier acquisition single-shot turbo spin echo and 3D-T1 volumetric interpolated breath-hold examination may be the most commonly used sequences for whole-body imaging due to their shorter acquisition time and higher diagnostic accuracy. Although there have been several reports that adding diffusion weighted image (DWI) to PET/MRI protocol has had no effect on tumor detection to date, in cases of liver, kidney, bladder, and prostate cancer, the use of DWI may be beneficial in detecting lesions. Another possible option is to scan each region with different MRI sequences instead of scanning the whole body using one sequence continuously. We herein report a workflow and imaging protocols for whole-body oncologic PET/MRI using an integrated system in the clinical routine, designed for the detection, for example by cancer screening, of metastatic lesions, in order to help future users optimize their workflow and imaging protocols.

  1. Whole-body MRI screening

    Energy Technology Data Exchange (ETDEWEB)

    Puls, Ralf [HELIOS Klinikum Erfurt (Germany). Inst. of Diagnostic and Interventional Radiology and Neuroradiology; Hosten, Norbert (ed.) [Universitaetsklinikum Greifswald (Germany). Diagnostic Radiology and Neuroradiology

    2014-07-01

    The advent of dedicated whole-body MRI scanners has made it possible to image the human body from head to toe with excellent spatial resolution and with the sensitivity and specificity of conventional MR systems. A comprehensive screening examination by MRI relies on fast image acquisition, and this is now feasible owing to several very recent developments, including multichannel techniques, new surface coil systems, and automatic table movement. The daily analysis of whole-body MRI datasets uncovers many incidental findings, which are discussed by an interdisciplinary advisory board of physicians from all specialties. This book provides a systematic overview of these incidental findings with the aid of approximately 240 high-quality images. The radiologists involved in the project have written chapters on each organ system, presenting a structured compilation of the most common findings, their morphologic appearances on whole-body MRI, and guidance on their clinical management. Chapters on technical and ethical issues are also included. It is hoped that this book will assist other diagnosticians in deciding how to handle the most common incidental findings encountered when performing whole-body MRI.

  2. Whole-body MRI screening

    International Nuclear Information System (INIS)

    Puls, Ralf; Hosten, Norbert

    2014-01-01

    The advent of dedicated whole-body MRI scanners has made it possible to image the human body from head to toe with excellent spatial resolution and with the sensitivity and specificity of conventional MR systems. A comprehensive screening examination by MRI relies on fast image acquisition, and this is now feasible owing to several very recent developments, including multichannel techniques, new surface coil systems, and automatic table movement. The daily analysis of whole-body MRI datasets uncovers many incidental findings, which are discussed by an interdisciplinary advisory board of physicians from all specialties. This book provides a systematic overview of these incidental findings with the aid of approximately 240 high-quality images. The radiologists involved in the project have written chapters on each organ system, presenting a structured compilation of the most common findings, their morphologic appearances on whole-body MRI, and guidance on their clinical management. Chapters on technical and ethical issues are also included. It is hoped that this book will assist other diagnosticians in deciding how to handle the most common incidental findings encountered when performing whole-body MRI.

  3. Evaluation of whole-body MR to CT deformable image registration

    NARCIS (Netherlands)

    Akbarzadeh, A.; Gutierrez, D.; Baskin, A.; Ay, M. R.; Ahmadian, A.; Alam, N. Riahi; Loevblad, K. O.; Zaidi, H.

    2013-01-01

    Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based

  4. Exercise thallium imaging in patients with diabetes mellitus. Prognostic implications

    International Nuclear Information System (INIS)

    Felsher, J.; Meissner, M.D.; Hakki, A.H.; Heo, J.; Kane-Marsch, S.; Iskandrian, A.S.

    1987-01-01

    We used exercise thallium 201 imaging in 123 patients with diabetes mellitus (77 men and 46 women, aged 56 +/- 8 years), 75% of whom had angina pectoris (typical or atypical). During exercise testing, 18 patients (15%) had angina pectoris, 28 (23%) had ischemic ST changes, and 69 (56%) had abnormal thallium images. During follow-up (up to 36 months), there were 12 cardiac events; four patients died of cardiac causes and eight had nonfatal acute myocardial infarction. Univariate and multivariate survival analysis identified two independent predictors of cardiac events: the event rate was significantly less in patients with normal images and exercise heart rate over 120 beats per minute than in patients with abnormal images and exercise heart rate of 120 beats per minute or less (0% vs 22%). The patients with abnormal images or exercise heart rate of 120 beats per minute or less had an intermediate event rate (11.5%). Furthermore, two of the 54 patients with normal images and ten of 69 patients with abnormal images had subsequent cardiac events. Thus, exercise thallium imaging is useful in risk stratification in patients with diabetes mellitus

  5. Improved quality of image got through whole-body CT scanner

    International Nuclear Information System (INIS)

    Asahina, Kiyotaka

    1980-01-01

    The quality of brain images taken with a whole-body CT scanner has so far been generally inferior in quality to those got through a CT scanner exclusively used for brains. In order to improve the whole-body CT scanner so as to get better brain image, its detection system has been made multichannel; the capacity of its X-ray tube, increased; and its software, innovated. As a result, the spatial resolution has been improved from 5.51 p/cm to 9.01 p/cm, the contrast resolution has been improved from 3.2 mm% to 1.5 mm%, with the noise maintained at 0.5%. In clinical examination, the image quality has been improved equally well for brains, abdomens and lungs. Especially high appreciation is given to the diagnosis information got through this new scanner. (author)

  6. Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation.

    Science.gov (United States)

    Karakatsanis, Nicolas A; Lodge, Martin A; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-10-21

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (~15-20 cm) of a single-bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole-body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate Ki and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final Ki parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion study

  7. Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation

    International Nuclear Information System (INIS)

    Karakatsanis, Nicolas A; Lodge, Martin A; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-01-01

    In the context of oncology, dynamic PET imaging coupled with standard graphical linear analysis has been previously employed to enable quantitative estimation of tracer kinetic parameters of physiological interest at the voxel level, thus, enabling quantitative PET parametric imaging. However, dynamic PET acquisition protocols have been confined to the limited axial field-of-view (∼15–20 cm) of a single-bed position and have not been translated to the whole-body clinical imaging domain. On the contrary, standardized uptake value (SUV) PET imaging, considered as the routine approach in clinical oncology, commonly involves multi-bed acquisitions, but is performed statically, thus not allowing for dynamic tracking of the tracer distribution. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. In a companion study, we presented a novel clinically feasible dynamic (4D) multi-bed PET acquisition protocol as well as the concept of whole-body PET parametric imaging employing Patlak ordinary least squares (OLS) regression to estimate the quantitative parameters of tracer uptake rate K i and total blood distribution volume V. In the present study, we propose an advanced hybrid linear regression framework, driven by Patlak kinetic voxel correlations, to achieve superior trade-off between contrast-to-noise ratio (CNR) and mean squared error (MSE) than provided by OLS for the final K i parametric images, enabling task-based performance optimization. Overall, whether the observer's task is to detect a tumor or quantitatively assess treatment response, the proposed statistical estimation framework can be adapted to satisfy the specific task performance criteria, by adjusting the Patlak correlation-coefficient (WR) reference value. The multi-bed dynamic acquisition protocol, as optimized in the preceding companion

  8. Enhanced detection of ischemic but viable myocardium by the reinjection of thallium after stress-redistribution imaging

    International Nuclear Information System (INIS)

    Dilsizian, V.; Rocco, T.P.; Freedman, N.M.; Leon, M.B.; Bonow, R.O.

    1990-01-01

    The identification of ischemic but viable myocardium by thallium exercise scintigraphy is often imprecise, since many of the perfusion defects that develop in ischemic myocardium during exercise do not fill in on subsequent redistribution images. We hypothesized that a second injection of thallium given after the redistribution images were taken might improve the detection of ischemic but viable myocardium. We studied 100 patients with coronary artery disease, using thallium exercise tomographic imaging and radionuclide angiography. Patients received 2 mCi of thallium intravenously during exercise, redistribution imaging was performed three to four hours later, and a second dose of 1 mCi of thallium was injected at rest immediately thereafter. The three sets of images (stress, redistribution, and reinjection) were then analyzed. Ninety-two of the 100 patients had exercise-induced perfusion defects. Of the 260 abnormal myocardial regions identified by stress imaging, 85 (33 percent) appeared to be irreversible on redistribution imaging three to four hours later. However, 42 of these apparently irreversible defects (49 percent) demonstrated improved or normal thallium uptake after the second injection of thallium, with an increase in mean regional uptake from 56 +/- 12 percent on redistribution studies to 64 +/- 10 percent on reinjection imaging (P less than 0.001). Twenty patients were restudied three to six months after coronary angioplasty. Of the 15 myocardial regions with defects on redistribution studies that were identified as viable by reinjection studies before angioplasty, 13 (87 percent) had normal thallium uptake and improved regional wall motion after angioplasty. In contrast, all eight regions with persistent defects on reinjection imaging before angioplasty had abnormal thallium uptake and abnormal regional wall motion after angioplasty

  9. Thallium imaging in management of post-revascularization patients

    International Nuclear Information System (INIS)

    Alazraki, N.; Krawczynska, E.

    1996-01-01

    The role of myocardial perfusion imaging in the evaluation of post revascularization patients has not been well defined. Published data with special emphasis on the results from the Emory Angioplasty versus Surgery Trial (EAST) indicate that the frequency of adverse cardiac events (death, MI, repeat revascularization) following PTCA or CABG is equal in symptomatic and asymptomatic patients with ischemic thallium defects. Current American Heart Association Guidelines recommend radionuclide studies only in symptomatic patients. Recently reported data support the need for non invasive testing in asymptomatic as well as symptomatic patients at 1 year postrevascularization. Prognostic variables including transient and permanent left ventricular dilatation and thallium lung uptake in addition to stress perfusion defect reversibility on myocardial thallium SPECT scans are important prognostic indicators in post revascularization patients

  10. Thallium scintigraphy used in the evaluation of soft tissue sarcoma

    International Nuclear Information System (INIS)

    Pilloni, A.; Brooks, R.

    1998-01-01

    Full text: The use of thallium scintigraphy in tumour localisation is a promising diagnostic modality. Thallium has a good affinity for numerous tumour types including sarcomas. Its properties as a potassium analogue result in active uptake via the sodium- potassium ATP-ase pump enabling its use in evaluating tumour extent, viability, staging, localisation and treatment. This case illustrates the role of thallium in tumour staging. A 67-year-old woman with a fibrous histiocytoma resected from the right foot four months previously presented with pain in the ribs, lower back and feet. A bone scan was performed to assess the possibility of metastatic disease. Several abnormal foci were seen on the bone scan suggestive of metastatic disease. A thallium scan was performed to confirm the bone scan result after a subsequent CT scan showed no evidence of this extensive disease. Static images of the whole body were acquired on an Elscinct 400AG 20 minutes post i.v. injection of 3.5 mCi of thallium. Focal areas of increased thallium uptake were seen in the 11th rib posteriorly and in the left sacroiliac region corresponding with sites on the bone scan suggesting metastases. However, an extensive area of uptake was also observed in the right inguinal region which had no corresponding abnormalities in the bone study. This was thought to be tumour metastasis in an inguinal Iymph node, which was retrospectively confirmed on an earlier CT scan of the pelvis. This study demonstrates the usefulness of thallium in the detection of soft tissue tumours and metastases. Thallium also exhibits potential in the assessment of tumour extent and viability pre- and post-treatment. This potential needs to be explored further in patient management

  11. Preoperative evaluation of myocardial viability by thallium-201 imaging in patients with old myocardial infarction who underwent coronary revascularization

    International Nuclear Information System (INIS)

    Naruse, Hitoshi; Ohyanagi, Mitsumasa; Iwasaki, Tadaaki; Miyamoto, Takashi; Fukuchi, Minoru

    1992-01-01

    The myocardial uptake and redistribution in thallium scintigraphy and the regional wall motion by echocardiography were evaluated by a semi-quantitative method in 42 patients who previously had myocardial infarction (50 target vessels) and underwent coronary revascularization. The aim of this study was to elucidate the significance of the initial image, delayed image and redistribution on thallium-201 scintigraphy for clinical diagnosis of the myocardial viability. As a semi-quantitative analysis, we used a bull's-eye display for thallium image and centerline method for echocardiographic wall motion, and compared the results before and after revascularization. As a result, the thallium grade improved postoperatively in all 17 areas which preoperatively had showed redistribution, and also in 11 of the 32 areas without preoperative redistribution. The sensitivity, specificity and accuracy of preoperative thallium redistribution for predicting myocardial viability were 61%, 100% and 78%, respectively, when the postoperative improvement in the thallium grade was used as the standard. The postoperative probability of improvement in the thallium grade increased in proportion to the preoperative grade (delayed image)(p<0.01). There was no correlation between the preoperative thallium delayed image and postoperative improvement in wall motion. Postoperative improvement in thallium image and wall motion could not be predicted from the preoperative wall motion. Thus, postoperative improvement in thallium images can be anticipated if redistribution is present on the preoperative thallium image, and the preoperative thallium delayed image is useful for predicting myocardial viability. Improvement in wall motion could not be predicted preoperatively by these methods. (author)

  12. Comparison of whole body MR diffusion weighted imaging and skeletal scintigraphy in detecting bone metastasis

    International Nuclear Information System (INIS)

    Xu Xian; Ma Lin; Zhang Jinshan; Cai Youquan; Cheng Liuquan; Guo Xinggao; Xu Baixuan

    2008-01-01

    Objective: To evaluate the application of whole body MR diffusion weighted imaging (DWI) in the detection of bone metastasis using skeletal scintigraphy as the reference. Methods: Forty-two healthy volunteers and 38 patients with malignant tumors were enrolled in our study. All the patients received MR examination and skeletal scintigraphy within one week. MR examination was performed on GE signa 3.0T MR scanner using a build-in body coil. The skeletal system was divided into eight regions and the images of the whole body MR DWI and skeletal scintigraphy were reviewed to compare the two modalities patient by patient and region by region. The images were reviewed separately by two radiologists and two nuclear medicine physicians, who were blinded to the results of another imaging modality. Results: A total of 169 metastatic lesions in 69 regions of 30 patients were detected by whole body MR DWI while 156 lesions in 68 regions of 29 patients were identified by skeletal scintigraphy. There were two cases negative in scintigraphy but positive in whole body MR DWI and one case positive in scintigraphy only. There were eight lesions negative in scintigraphy but positive in whole body MR DWI, mainly located in the spine, pelvis and femur. Seven lesions were only detected by scintigraphy, mainly located in the skull, sternum, clavicle and scapula. Conclusion: The whole body MR DWI reveals excellent consistency with skeletal scintigraphy regarding bone metastasis, and the two modalities are complementary for each other. (authors)

  13. Myocardial imaging in coronary heart disease with radionuclides, with emphasis on thallium-201

    Energy Technology Data Exchange (ETDEWEB)

    Wackers, F J.Th.; Sokole, E B; Samson, G; van der Schoot, J B; Wellens, H J.J. [Amsterdam Univ. (Netherlands). Academisch Ziekenhuis

    1976-09-01

    During the past few years there has been an increasing interest in cardiology for myocardial imaging with radionuclides. At present the experience with both negative (thallium-201) and positive (sup(99m)Tc-pyrophosphate) imaging of myocardial infarction is increasing rapidly. Since 1974, over 1100 patient studies with thallium-201 were performed. In this article a survey is presented of experience with thallium-201 in patients with acute and chronic coronary artery disease. In patients with acute myocardial infarction data from studies with sup(99m)Tc-pyrophosphate will be discussed as well.

  14. Comparison of diagnostic value of coronary artery disease between ATP-stress and exercise-stress thallium myocardial SPECT images

    International Nuclear Information System (INIS)

    Suzuki, Shigeo

    1994-01-01

    A study was made between adenosine triphosphate disodium (ATP)-stress thallium myocardial scintigrams and exercise-stress scintigrams to compare their respective extents and degree of defects. The subjects of the study were 33 ischemic heart disease patients, who received ATP stress and treadmill exercise stress with a mean interval of 25 days. ATP was infused for 5 minutes with an infusion rate of 0.16 or 0.18 mg per kg of body weight per minute. Thallium was injected three minutes after infusion. The percent-defect index (percentage of the extent and degree of the defects for all 33 patients), was calculated with visual scoring using a five-zone myocardial division method and semi-quantitative four-grade representation method for both the ATP and exercise SPECT images. The extent of the defects in ATP- and exercise-stress images was 51.5% and 44.2%, and that in redistribution images was 36.4% and 33.9%, respectively. The degree of defects in ATP- and exercise-stress images was 35.8% and 32.3%, while that in redistribution images was 20.8% and 17.2%, respectively (p=NS in all cases). In conclusion, the image quality of thallium SPECT with ATP stress was equivalent that of exercise stress, indicating identical diagnostic values for coronary lesions. (author)

  15. Evaluation of whole-body MR to CT deformable image registration.

    Science.gov (United States)

    Akbarzadeh, A; Gutierrez, D; Baskin, A; Ay, M R; Ahmadian, A; Riahi Alam, N; Lövblad, K O; Zaidi, H

    2013-07-08

    Multimodality image registration plays a crucial role in various clinical and research applications. The aim of this study is to present an optimized MR to CT whole-body deformable image registration algorithm and its validation using clinical studies. A 3D intermodality registration technique based on B-spline transformation was performed using optimized parameters of the elastix package based on the Insight Toolkit (ITK) framework. Twenty-eight (17 male and 11 female) clinical studies were used in this work. The registration was evaluated using anatomical landmarks and segmented organs. In addition to 16 anatomical landmarks, three key organs (brain, lungs, and kidneys) and the entire body volume were segmented for evaluation. Several parameters--such as the Euclidean distance between anatomical landmarks, target overlap, Dice and Jaccard coefficients, false positives and false negatives, volume similarity, distance error, and Hausdorff distance--were calculated to quantify the quality of the registration algorithm. Dice coefficients for the majority of patients (> 75%) were in the 0.8-1 range for the whole body, brain, and lungs, which satisfies the criteria to achieve excellent alignment. On the other hand, for kidneys, Dice coefficients for volumes of 25% of the patients meet excellent volume agreement requirement, while the majority of patients satisfy good agreement criteria (> 0.6). For all patients, the distance error was in 0-10 mm range for all segmented organs. In summary, we optimized and evaluated the accuracy of an MR to CT deformable registration algorithm. The registered images constitute a useful 3D whole-body MR-CT atlas suitable for the development and evaluation of novel MR-guided attenuation correction procedures on hybrid PET-MR systems.

  16. Sex differences in the tracer distribution on stress thallium-201 imaging, (1)

    International Nuclear Information System (INIS)

    Tamaki, Nagara; Koda, Hideki; Adachi, Yukihide; Sugihara, Takao; Kato, Mihoko; Tanaka, Nobuyuki; Tamari, Kimimasa.

    1988-01-01

    To determine the sex differences in the tracer distribution on stress thallium-201 imaging, the studies of 18 normal males and 18 normal females were subjected to quantitative circumferential profile analysis in each projection image. Although the exercise duration was shorter in females (11±3 min) than in males (14±3 min) (p<0.01), the peak heart rate, peak systolic pressure and the lung-to-myocardial count ratio were similar between them. The averaged profile curves in female showed a significant reduction in tracer uptake in anterior and upper septal regions, particularly in the study of lateral view, which may be attributed to breast attenuation. In addition, the percent washout of thallium in 3 hours was higher in females (48±8%) than in males (43±7%) (p<0.01), particularly in the study of anterior view. We conclude that important differences in the pattern of thallium uptake and washout between males and females should be considered for interpretation of stress thallium imaging. (author)

  17. Determination of cardiac risk by dipyridamole-thallium imaging before peripheral vascular surgery

    International Nuclear Information System (INIS)

    Boucher, C.A.; Brewster, D.C.; Darling, R.C.; Okada, R.D.; Strauss, H.W.; Pohost, G.M.

    1985-01-01

    To evaluate the severity of coronary artery disease in patients with severe peripheral vascular disease requiring surgery, preoperative dipyridamole-thallium imaging was performed in 54 stable patients with suspected coronary artery disease. Of the 54 patients, 48 had peripheral vascular surgery as scheduled without coronary angiography, of whom 8 (17 per cent) had postoperative cardiac ischemic events. The occurrence of these eight cardiac events could not have been predicted preoperatively by any clinical factors but did correlate with the presence of thallium redistribution. Eight of 16 patients with thallium redistribution had cardiac events, whereas there were no such events in 32 patients whose thallium scan either was normal or showed only persistent defects (P less than 0.0001). Six other patients also had thallium redistribution but underwent coronary angiography before vascular surgery. All had severe multivessel coronary artery disease, and four underwent coronary bypass surgery followed by uncomplicated peripheral vascular surgery. These data suggest that patients without thallium redistribution are at a low risk for postoperative ischemic events and may proceed to have vascular surgery. Patients with redistribution have a high incidence of postoperative ischemic events and should be considered for preoperative coronary angiography and myocardial revascularization in an effort to avoid postoperative myocardial ischemia and to improve survival. Dipyridamole-thallium imaging is superior to clinical assessment and is safer and less expensive than coronary angiography for the determination of cardiac risk

  18. Myocardial infarction after dipyridamole-assisted thallium-201 imaging

    International Nuclear Information System (INIS)

    Biddle, P.; Lanspa, T.J.; Mohiuddin, S.M.; Malesker, M.A.; Hilleman, D.E.

    1989-01-01

    A 77-year-old woman with suspected coronary artery disease underwent an oral dipyridamole/thallium-201 myocardial imaging study. Approximately 75 minutes after ingestion of dipyridamole 300 mg suspension, the patient developed chest pain, hypotension, nausea, and diaphoresis. An electrocardiogram revealed ST-T wave changes suggestive of inferior ischemia. Appropriate therapeutic measures, including aminophylline and nitroglycerin, were instituted. Delayed thallium images revealed reversible ischemia in the anteroseptal and posterobasal regions with a fixed defect in the inferobasal region. Cardiac enzyme studies were also indicative of acute myocardial injury. The patient subsequently underwent coronary arteriography and four-vessel coronary artery bypass grafting and was discharged without further complication. This report raises concerns about the potential danger of dipyridamole in patients with severe coronary artery stenosis and collateral circulation. Prophylactic aminophylline should be considered in these patients

  19. Serial thallium-201 imaging after dipyridamole for coronary disease detection: quantitative analysis using myocardial clearance

    International Nuclear Information System (INIS)

    Okada, R.D.; Dai, Y.H.; Boucher, C.A.; Pohost, G.M.

    1984-01-01

    After dipyridamole, canine studies have demonstrated a slower rate of myocardial thallium-201 clearance from zones distal to a coronary artery stenosis compared to normal zones. To determine if criteria based on canine myocardial thallium-201 clearance rates could be applied clinically, 40 patients with and 26 patients without coronary artery disease (CAD) had serial thallium-201 images obtained for 2 to 5 hours after dipyridamole. Regions of interest were manually placed over six left ventricular segments in two projections for each of three imaging times. The myocardial thallium-201 clearance rate was calculated for each of the six segments and, using the clearance rate criterion found in canine studies, was considered abnormal if less than 6.5%/hr. Using this criterion alone, 22 of 26 patients (85%) without CAD had normal and 30 of 40 patients (75%) with CAD had abnormal myocardial thallium-201 clearance rates. A quantitative analysis of regional inhomogeneity in tracer distribution (normal was greater than or equal to 25% difference between segments) was negative in 24 of 26 patients (92%) without CAD and positive in 20 of 40 patients (50%) with CAD. When both clearance rate and regional inhomogeneity were considered, 21 of 26 patients (81%) without CAD had negative and 36 of 40 patients (90%) with CAD had positive results. Thus, post-dipyridamole myocardial clearance rate criteria derived from canine studies can be applied to clinical thallium imaging. Quantitative analysis of serial thallium-201 images after dipyridamole is optimized by using myocardial thallium-201 clearance rates. Such an approach is independent of regional inhomogeneities in tracer distribution

  20. Lung uptake of thallium-201 on resting myocardial imaging in assessment of pulmonary edema

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, N.; Yonekura, Y.; Yamamoto, K. (Kyoto Univ. (Japan). Hospital)

    1981-03-01

    We have noted increased lung uptake of thallium-201 on resting myocardial images in patients with congestive heart failure. To evaluate this phenomenon, lung uptake of thallium on resting myocardial imaging was examined in 328 patients with various cardiovascular diseases. Increased lung uptake was observed in 117 cases (78%) with myocardial infarction, 32 (37%) with angina pectoris, 6 (27%) with hypertensive heart disease, 7 (30%) with hypertrophic cardiomyopathy, 6 (100%) with congestive cardiomyopathy, 11 (100%) with valvular heart disease, and 7 (71%) with congenital heart disease, however, only one (5%) of normal subjects revealed increased uptake. Left ventricular ejection fraction was evaluated in 32 cases with ischemic heart disease on the same day and it was significantly decreased as the lung uptake of thallium increased. Increased thallium activity in the lung seemed to be another noninvasive marker of lift heart failure in ischemic heart disease. Lung uptake of thallium was compared with pulmonary congestive signs on chest X-ray in 29 cases. The uptake was well correlated with the degree of pulmonary edema, and thallium myocardial image revealed remarkably increased lung uptake in all the patients accompanied with pulmonary interstitial edema on chest X-ray. Therefore, this phenomenon will demonstrate pulmonary edema, since thallium may be extracted to the increased interstitial distribution space of the lung as well as the myocardium in a patient with pulmonary edema. We conclude that thallium myocardial scintigraphy is useful not only in identification and localization of myocardial ischemia or infarction, but also in evaluation of pulmonary edema at the same time.

  1. Lung uptake of thallium-201 on resting myocardial imaging in assessment of pulmonary edema

    International Nuclear Information System (INIS)

    Tamaki, Nagara; Yonekura, Yoshiharu; Yamamoto, Kazutaka

    1981-01-01

    We have noted increased lung uptake of thallium-201 on resting myocardial images in patients with congestive heart failure. To evaluate this phenomenon, lung uptake of thallium on resting myocardial imaging was examined in 328 patients with various cardiovascular diseases. Increased lung uptake was observed in 117 cases (78%) with myocardial infarction, 32 (37%) with angina pectoris, 6 (27%) with hypertensive heart disease, 7 (30%) with hypertrophic cardiomyopathy, 6 (100%) with congestive cardiomyopathy, 11 (100%) with valvular heart disease, and 7 (71%) with congenital heart disease, however, only one (5%) of normal subjects revealed increased uptake. Left ventricular ejection fraction was evaluated in 32 cases with ischemic heart disease on the same day and it was significantly decreased as the lung uptake of thallium increased. Increased thallium activity in the lung seemed to be another noninvasive marker of lift heart failure in ischemic heart disease. Lung uptake of thallium was compared with pulmonary congestive signs on chest X-ray in 29 cases. The uptake was well correlated with the degree of pulmonary edema, and thallium myocardial image revealed remarkably increased lung uptake in all the patients accompanied with pulmonary interstitial edema on chest X-ray. Therefore, this phenomenon will demonstrate pulmonary edema, since thallium may be extracted to the increased interstitial distribution space of the lung as well as the myocardium in a patient with pulmonary edema. We conclude that thallium myocardial scintigraphy is useful not only in identification and localization of myocardial ischemia or infarction, but also in evaluation of pulmonary edema at the same time. (author)

  2. Decrease in the ability to detect elevated lung thallium due to delay in commencing imaging after exercise

    International Nuclear Information System (INIS)

    Rothendler, J.A.; Boucher, C.A.; Strauss, H.W.; Pohost, G.M.; Okada, R.D.

    1985-01-01

    Post-exercise elevation of the lung/myocardial thallium ratio and a high lung clearance rate between initial and delayed images have been reported to be markers for exercise-induced left ventricular (LV) dysfunction associated with coronary artery disease (CAD). The authors performed thallium exercise tests on 60 patients, 42 with CAD, in order to determine the effect of delaying initial imaging on detection of elevated lung thallium. In addition to images obtained at 2 minutes and at 2 hours after exercise, 18-minute images were also obtained to simulate such a delay. Because of rapid isotope clearance in those with initially elevated lung activity, there was decreased sensitivity of both the initial lung/myocardial ratio and lung thallium clearance for detecting CAD, using the 18-minute image as the initial post exercise study. They conclude that initial imaging should be done in the anterior view early after exercise to optimize detection of elevated lung thallium

  3. Role of exercise thallium 201 imaging in decision making

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Segal, B.L.; Frankl, W.S.; Kane-Marsch, S.; Unger, J.

    1986-01-01

    This prospective study examined the impact of results of exercise thallium 201 imaging on the estimation of probability of coronary artery disease (CAD) and patient management among cardiologists and internists in our institution. Before exercise testing, the probability of CAD in the 100 patients enrolled in this study was considered low in 31, intermediate in 28, and high in 41 patients. The probability of CAD after exercise thallium imaging was different in four patients (10%) in the high group, 22 patients (79%) in the intermediate group, and three patients (10%) in the low group. Further, the results of exercise testing resulted in changes in patient management in 29 patients (71%) in the high group, 26 patients (93%) in the intermediate group, and 16 patients (52%) in the low group. Overall, the management changed in 71% of the patients. This change included changes in medications, physical activity, frequency of office visits, need for cardiac catheterization, and need for coronary arterial bypass grafting. Thus, exercise thallium imaging is useful in clinical decision making: the diagnostic certainty is improved in patients with intermediate pretest probability of CAD; and some degree of change in patient management is observed, even in patients in whom the probability of CAD is not altered

  4. The clinical value of "9"9Tc"m-MDP whole body bone imaging in diagnosing bone metastasis of lung cancer

    International Nuclear Information System (INIS)

    Zhao Yigang; Gou Zhengxing

    2016-01-01

    Objective: To discuss the clinical value of whole body bone imaging on lung cancer bone metastases diagnosis, so as to evaluate the staging of lung cancer patients. Methods: A total of 113 cases of patients diagnosed with lung cancer received whole body imaging, alkaline phosphatase and blood calcium examination. Bone metastasis probability of lung cancer was assessed based on different pathological types. Accuracy rates of bone metastases was compared by whole body bone imaging and suspicious bone metastasis factors (Including one or several items in ostalgia, alkaline phosphatase rising and hypercalcemia). Results The occurrence rate of lung cancer bone metastasis is 36.7%, and the bone metastasis occurrence rate of adenocarcinoma of lung is higher than that of squamous cell lung carcinoma (P < 0.01). Whole body Imaging diagnose of lung cancer bone metastases had sensitivity (92.7%), specificity (83.2%) and accuracy (85.7%). Conclusion: "9"9Tc"m-MDP whole body imaging is a highly sensitive tool to review whole body bone. Lung cancer patients are recommended to receive routine whole body bone imaging. (authors)

  5. Patient-Specific Biomechanical Model as Whole-Body CT Image Registration Tool

    OpenAIRE

    Li, Mao; Miller, Karol; Joldes, Grand Roman; Doyle, Barry; Garlapati, Revanth Reddy; Kikinis, Ron; Wittek, Adam

    2015-01-01

    Whole-body computed tomography (CT) image registration is important for cancer diagnosis, therapy planning and treatment. Such registration requires accounting for large differences between source and target images caused by deformations of soft organs/tissues and articulated motion of skeletal structures. The registration algorithms relying solely on image processing methods exhibit deficiencies in accounting for such deformations and motion. We propose to predict the deformations and moveme...

  6. The four-dimensional mouse whole-body phantoms and its application in medical imaging research

    International Nuclear Information System (INIS)

    Li Chongguo; Wu Dake

    2012-01-01

    Medical imaging simulation is a powerful tool for characterizing,evaluating,and optimizing medical imaging devices and techniques. A vital aspect of simulation is to have a realistic phantom or model of the subject's anatomy. Four-dimensional mouse whole-body phantoms provide realistic models of the mouse anatomy and physiology for imaging studies. When combined with accurate models for the imaging process,are capable of providing a wealth of realistic imaging data from subjects with various anatomies and motions (cardiac and respiratory) in health and disease. With this ability, the four-dimensional mouse whole-body phantoms have enormous potential to study the effects of anatomical, physiological and physical factors on medical and small animal imaging and to research new instrumentation, image acquisition strategies, image processing, reconstruction methods, image visualization and interpretation techniques. (authors)

  7. Prevalence and correlates of increased lung/heart ratio of thallium-201 during dipyridamole stress imaging for suspected coronary artery disease

    International Nuclear Information System (INIS)

    Villanueva, F.S.; Kaul, S.; Smith, W.H.; Watson, D.D.; Varma, S.K.; Beller, G.A.

    1990-01-01

    There is little information concerning the prevalence and clinical correlates of increased pulmonary thallium-201 uptake during dipyridamole thallium-201 stress imaging. Accordingly, the clinical characteristics and quantitative thallium-201 findings were correlated with quantitative lung/heart thallium-201 ratio in 87 patients undergoing dipyridamole thallium-201 stress testing. Nineteen patients (22%) had an elevated ratio (greater than 0.51). These patients were more likely to have had an infarction, to be taking beta blockers, and have a lower rate-pressure product after dipyridamole administration than those with a normal ratio (p less than 0.03). An elevated ratio was associated with a greater likelihood of initial, redistribution and persistent defects, as well as left ventricular cavity dilatation on thallium-201 imaging (p less than 0.05). In addition, the number of myocardial segments demonstrating initial, redistribution and persistent defects was also greater in patients with increased ratios (p less than 0.03). Multivariate analysis demonstrated that the presence of redistribution and left ventricular cavity dilatation were the most significant correlates of lung/heart thallium-201 ratio. It is concluded that the prevalence of increased lung/heart thallium-201 ratio with dipyridamole thallium-201 stress imaging is similar to that seen with exercise stress imaging. As with exercise thallium-201 imaging, increased pulmonary thallium-201 uptake may be a marker of functionally more significant coronary artery disease

  8. Image artifacts from MR-based attenuation correction in clinical, whole-body PET/MRI

    DEFF Research Database (Denmark)

    Keller, Sune H; Holm, Søren; Hansen, Adam E

    2013-01-01

    Integrated whole-body PET/MRI tomographs have become available. PET/MR imaging has the potential to supplement, or even replace combined PET/CT imaging in selected clinical indications. However, this is true only if methodological pitfalls and image artifacts arising from novel MR-based attenuation...

  9. Cryo-sectioning of mice for whole-body imaging of drugs and metabolites with desorption electrospray ionization mass spectrometry imaging - a simplified approach

    DEFF Research Database (Denmark)

    Okutan, Seda; Hansen, Harald S; Janfelt, Christian

    2016-01-01

    A method is presented for whole-body imaging of drugs and metabolites in mice with desorption electrospray ionization mass spectrometry imaging (DESI-MSI). Unlike most previous approaches to whole-body imaging which are based on cryo-sectioning using a cryo-macrotome, the presented approach...... to simple, sensitive and highly selective whole-body imaging in drug distribution and metabolism studies....... is based on use of the cryo-microtome which is found in any histology lab. The tissue sections are collected on tape which is analyzed directly by DESI-MSI. The method is demonstrated on mice which have been dosed intraperitoneally with the antidepressive drug amitriptyline. By combining full...

  10. The assessment of whole body bone SPECT in oncology

    International Nuclear Information System (INIS)

    Scortechini, Shonika

    2009-01-01

    Full text: Objectives: To assess the significance and practicability of oncology whole body bone SPECT as part of the standard skeletal survey and its impact on the traditional planar whole body bone imaging protocol. Method: Three consenting oncology patients were injected with a standard adult dose of Tc-99m MOP. Delayed Imaging of whole body sweep and SPECT acquisitions were performed on a Siemens Symbia T6. The patient was positioned supine with arms down with a SPECT scan length covering vortex to thighs. SPECT data was reconstructed and a single whole body zipped file created. Normal SPECT slices along with a cine/MIP of the zipped data were created for review. Results: Both image data sets were reviewed to assess if SPECT provided any further diagnostic clinical information not apparent in planer imaging. In our limited review, whole body SPECT did not add extra value to the planar whole body scans performed; it did however demonstrate vertebral involvement with greater resolution. The processing software and system limitations in seamlessly knitting data sets (creating image artefacts) was a major limiting factor in not pursuing further studies. Conclusion: Both imaging techniques offer differing advantages and limitations, however due to image artefact in the triple knitted SPECT approach with current software technology, it cannot be substituted for whole body imaging at this time.

  11. A serial changes of thallium-201 myocardial images in a patient with nontransmural myocardial infarction

    International Nuclear Information System (INIS)

    Tanaka, Takeshi; Itoh, Yukiyoshi; Takayama, Yasuo

    1986-01-01

    A 66 year old man had suffered from inferior myocardial infarction one year ago and then suffered from effort angina. Recently rest angina attack frequently occurred and he was admitted because of angina attack refractory to TNG. The patient was diagnosed as broad nontransmural infarction. A serial thallium-201 myocardial imagings at rest and thallium-201 lung uptake imagings were performed and some interesting findings were obtained as followings. Myocardial imagings on 3rd day after admission showed no significant deffect, however EF was 34 %. Immediately after severe ischemic attack marked defect was noted at posterolateral region and ECG showed prominent precordial ST depression without accompanying significant ST change in II, III, aVF. On 3rd day after severe attack under hemodynamically and electrocardiographically stable state posterolateral defect improved, though still persisted. EF was 28 %. On 3rd day postop no marked defects were noted in myocardial imagings, so posterolateral defect at rest after severe ischemic attack was proved to be transient defect. In this case thallium-201 lung uptake was not noted before attack. Immediately after severe attack thallium lung uptake increased and maximal uptake was noted at basal zone of lung, however in chest X-P typical butterfly shadow was noted at upper zone of lung. On 3rd day after severe attack hemodynamics improved and butterfly shadow ceased, though thallium lung uptake increased and noted at upper zone of lung. After operation thallium lung uptake improved. (J.P.N.)

  12. Evaluation of quantitative planar 90Y bremsstrahlung whole-body imaging

    International Nuclear Information System (INIS)

    Minarik, D; Ljungberg, M; Gleisner, K Sjoegreen; Segars, P

    2009-01-01

    With high-dose administration of 90 Y labeled antibodies, it is possible to image 90 Y without an admixture of 111 In. We have earlier shown that it is possible to perform quantitative 90 Y bremsstrahlung SPECT for dosimetry purposes with reasonable accuracy. However, whole-body (WB) activity quantification with the conjugate view method is not as time consuming as SPECT and has been the method of choice for dosimetry. We have investigated the possibility of using a conjugate view method where scatter-, backscatter- and septal-penetration compensations are performed by inverse filtering and attenuation correction is performed with a WB x-ray image, for total-body and organ activity quantification of 90 Y. The method was evaluated using both Monte Carlo simulated scintillation camera images using realistic source distributions, and by an experimental phantom study. The method was evaluated in terms of image quality and accuracy of the activity quantification. The experimental phantom study was performed using the RSD torso phantom with 90 Y activity uniformly distributed in the liver insert. A GE Discovery VH/Hawkeye system was used to acquire the image. The simulation study was performed for a realistic activity distribution in the NCAT anthropomorphic phantom where 90 Y bremsstrahlung images were generated using the SIMIND MC program. Two different phantom configurations and two activity distributions were simulated. To mimic the RSD phantom experiment one simulation study was also made with 90 Y activity located only in the liver. The SIMIND program was configured to resemble a GE Discovery VH/Hawkeye system. An x-ray projector program was used to generate whole-body x-ray images from the NCAT phantom for attenuation correction in the conjugate view method. Organ activities were calculated from ROIs that exactly covered the organs. Corrections for background activity, overlapping activity and source extension in the depth direction were applied on the ROI data

  13. Trial making of a positive drawing phantom and its application to whole-body imaging devices

    International Nuclear Information System (INIS)

    Saegusa, Kenji; Arimizu, Noboru; Nakata, Tsuneo; Toyama, Haruo; Shiina, Isamu.

    1980-01-01

    In whole-body RI imaging, there are more instances of the positive pictures detecting the radioisotopes accumulating in morbid positions, such as Tc-99m bone scanning. The phantoms used to mutually compare RI imaging devices and to test their performance employ negative drawing targets embedded rather than positive ones. A simple positive drawing phantom has been made for trial, and applying this to whole-body scanning devices, the performance and the target drawing ability under different scanning conditions were comparatively examined. Though similar to Rollo's phantom, the phantom made for positive drawing uses acryl plate for its outer structure and target portions. The positive targets are cylindrical, and the diameters are 2, 4, 6, 8, 10, and 20 mm, and the subject contrasts are 5, 2, 1, 0.5 and 0.2. The aqueous solution of Tc-99m of about 2 mCi was injected into the phantom, and this was scanned with a whole-body camera and a multi-detector type whole-body scanner. With the phantom pictures close to actual clinical condition, the positive drawing phantom is conveniently capable of comparing the respective imaging devices for intended purposes. (J.P.N.)

  14. Resting technetium-99m methoxyisobutylisonitrile cardiac imaging in chronic coronary artery disease: comparison with rest-redistribution thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Cuocolo, A.; Maurea, S.; Pace, L.; Nicolai, E.; Nappi, A.; Imbriaco, M.; Trimarco, B.; Salvatore, M.

    1993-01-01

    We studied 19 patients with angiographically proven coronary artery disease and left ventricular dysfunction (ejection fraction 33%±8%) by resting technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) and rest-redistribution thallium-201 cardiac imaging. Thallium and 99m Tc-MIBI studies were visually analysed. Of 285 segments, 203 (71%) had normal thallium uptake, 48 (17%) showed reversible thallium defects and 34 (12%) showed irreversible thallium defects. Of these 34 irreversible thallium defects, 19 (56%) were moderate and 15 (44%) were severe. Of the corresponding 285 segments, 200 (70%) had normal 99m Tc-MIBI uptake, while 37 (13%) showed moderate and 48 (17%) showed severe reduction of MIBI uptake. Myocardial segmental agreement for regional uptake score between initial thallium and resting 99m Tc-MIBI images was 90% (κ=0.78). Segmental agreement between delayed thallium and resting 99m Tc-MIBI images was 77% (κ=0.44). In particular, in 26 (9%) segments 99m Tc-MIBI uptake was severely reduced while delayed thallium uptake was normal or only moderately reduced. These data suggest that although rest-redistribution thallium and resting 99m Tc-MIBI cardiac imaging provide concordant results in the majority of myocardial segments, some segments with severely reduced resting 99m Tc-MIBI uptake may contain viable but hypoperfused myocardium. Thus, conclusions on myocardial viability based on 99m Tc-MIBI uptake should be made with caution in chronic coronary artery disease. (orig.)

  15. Small-animal whole-body imaging using a photoacoustic full ring array system

    Science.gov (United States)

    Xia, Jun; Guo, Zijian; Aguirre, Andres; Zhu, Quing; Wang, Lihong V.

    2011-03-01

    In this report, we present a novel 3D photoacoustic computed tomography (PACT) system for small-animal whole-body imaging. The PACT system, based on a 512-element full-ring transducer array, received photoacoustic signals primarily from a 2-mm-thick slice. The light was generated by a pulse laser, and can either illuminate from the top or be reshaped to illuminate the sample from the side, using a conical lens and an optical condenser. The PACT system was capable of acquiring an in-plane image in 1.6 s; by scanning the sample in the elevational direction, a 3D tomographic image could be constructed. We tested the system by imaging a cylindrical phantom made of human hairs immersed in a scattering medium. The reconstructed image achieved an in-plane resolution of 0.1 mm and an elevational resolution of 1 mm. After deconvolution in the elevational direction, the 3D image was found to match well with the phantom. The system was also used to image a baby mouse in situ; the spinal cord and ribs can be seen easily in the reconstructed image. Our results demonstrate that the PACT system has the potential to be used for fast small-animal whole-body tomographic imaging.

  16. Tc99m-Tetrofosmin and Thallium-201 SPECT imaging of pituitary tumors: Preliminary results

    International Nuclear Information System (INIS)

    Yarman, S.; Mudun, A.

    2002-01-01

    Aim: It has been reported that pituitary adenomas accumulate Thallium -201(Tl-201), Tc99m-sestamibi and In111-Octreotide. These agents maybe useful in the diagnosis and follow-up of pituitary adenomas. Tc99m-tetrofosmin also has been shown as an tumor seeking agent in various tumors. The aim of this study is to evaluate the accumulation of Tc99m-tetrofosmin in pituitary adenomas and compare the results to Tl-201 SPECT. Methods: We performed Tc99m-Tetrofosmin and Tl-201 SPECT imaging on 5 patients (pts) with pituitary tumors, 3 patients with acromegaly, 1 patient with macro prolactinoma, and 1 patient with nonfunctional tumor (1 female, 4 male, age range: 26-50). SPECT imaging of cranium were obtained 20 min after intravenous injection of 111 MBq Tl-201 and 555 MBq Tc99m-Tetrofosmin on different days with a dual head gamma camera. All but one patient had surgical therapy. One patient had medical treatment. One patient had post surgical imaging with both Tetrofosmin and Tl-201 and 2 pts had only with Thallium. Semiquantitative analysis were performed by calculating tumor to background ratio from the mean counts of the created ROI's. Results: All adenomas showed prominent uptake with both Thallium and Tetrofosmin. The mean tumor to background ratios were 2.3 (range: 1.2-4.29) with Thallium and 3.57 (range: 1.6-6.86) with Tetrofosmin. Post therapy images showed no significant uptake in pituitary region with both agents in 2 patients. Post therapy mean Thallium uptake ratio in 3 pts was 1.64. One patient with acromegaly showed no decrease in thallium uptake, but showed some decrease in tetrofosmin uptake. Conclusion: Although our patient number is limited, these preliminary results indicate that Tc99m-tetrofosmin has also strong affinity for pituitary adenomas as does Thallium, either the adenoma is functioning or non-functioning. It may have a potential value to evaluate the response to therapy

  17. Thallium-201 myocardial imaging in evaluation of asymptomatic individuals with ischaemic ST segment depression on exercise electrocardiogram

    International Nuclear Information System (INIS)

    Caralis, D.G.; Bailey, I.; Kennedy, H.L.; Pitt, B.

    1979-01-01

    This study showed that asymptomatic adults with normal physical examination, normal resting electrocardiogram, and normal routine laboratory evaluation who had a positive exercise electrocardiogram and abnormal exercise thallium-201 myocardial image had a very high probability of angiographically significant coronary artery disease. If, on the other hand, the exercise electrocardiogram was positive for 'ischaemic' ST segment changes, but the exercise thallium image was normal, the probability for coronary disease was low. The exercise electrocardiogram combined with thallium-201 myocardial image are safe non-invasive methods which can be performed on an out-patient basis. (author)

  18. Evaluation of initial uptake and redistribution on stress thallium-201 myocardial perfusion images in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Watanabe, Yoshihiko; Tonooka, Ichiroh; Kanaya, Tohru; Tsuiki, Kai; Yasui, Shouji.

    1984-01-01

    Stress thallium-201 myocardial perfusion imaging was performed on 29 patients with previous myocardial infarction and 29 patients with angina pectoris at exercise to evaluate thallium-201 kinetics in ischemic heart disease. Four views of thallium-201 images (right anterior oblique, antero-posterior, left anterior oblique and left lateral views) were obtained at 5 min after treadmill exercise with administration of 2 mCi of thallium-201 chloride (initial image) and at 3 hours later (delayed image). Myocardial images were divided into 6 segments (anterior, lateral, inferior, posterior, apical and septal segments) and initial uptake (IU) and redistribution index (RDI, the ratio of the maximal washout rate to a washout rate in each segment) were calculated in order to assess the relations of thallium-201 kinetics to wall motion abnormality and coronary artery stenosis. In myocardial infarction, IU and RDI were decreased in proportion to the severity of wall motion abnormality and coronary artery stenosis. Contrarily, in angina pectoris, IU was decreased but RDI was increased proportionally to the severity of coronary arterial stenosis. In conclusion, IU and redistribution of thallium-201 were affected essentially by both the grade of coronary arterial stenosis and the amount of residual viable heart muscle in patients with ischemic myocardial disease. (author)

  19. Rest/exercise thallium myocardial perfusion imaging: a new and rapid technique to evaluate coronary artery disease

    International Nuclear Information System (INIS)

    Segall, G.M.; Zipkin, R.E.; Stanford Univ., CA

    1993-01-01

    Twenty-six patients underwent conventional exercise/4-h redistribution thallium myocardial perfusion imaging as well as rest/exercise imaging on different days. For the rest/exercise study, patients were inmaged 10 min after receiving 1 mCi thallium at rest. The resting study was immediately followed by symptom-limited treadmill exercise. Patients were injected with 2 mCi thallium at peak exercise and imaged 10 min later. The entire rest/exercise study was completed in 2 h. There was a high degree of correlation between the two studies. Of the 130 segments analysed, 84 were normal and 46 were abnormal by exercise/redistribution imaging whereas 88 were normal and 42 were abnormal by rest/exercise imaging. Among the 14 patients who had coronary arteriography, both exercise/redistribution and rest/exercise imaging correctly identified 23/35 segments as abnormal (sensitivity [pi003] 66% and 34/35 segments as normal (specificity=97%). Furthermore, abnormal segments were more likely to be reversible on the rest/exercise study. The results suggest that the accuracy of rest/exercise thallium imaging is equal to conventional exercise/redistribution imaging in the evaluation of coronary artery disease. The significant time economy and possible improvement in assessing myocardial viability are important potential advantages of this new technique. (Author)

  20. Cerebral blood flow imaging with thallium-201 diethyldithiocarbamate SPECT

    NARCIS (Netherlands)

    van Royen, E. A.; de Bruïne, J. F.; Hill, T. C.; Vyth, A.; Limburg, M.; Byse, B. L.; O'Leary, D. H.; de Jong, J. M.; Hijdra, A.; van der Schoot, J. B.

    1987-01-01

    Thallium-201 diethyldithiocarbamate ([201TI]DDC) was studied in humans as an agent for cerebral blood flow imaging. Brain uptake proved to be complete 90 sec after injection with no appreciable washout or redistribution for hours. Intracarotid injection suggested an almost 100% extraction during the

  1. Optimization of whole-body PET imaging protocol for the detection of 18F-FDG overlappings in oncology

    International Nuclear Information System (INIS)

    Lartizien, C.

    2001-01-01

    Positron emission tomography (PET) is a nuclear imaging modality that allows studying in vivo cellular metabolic and biochemical processes. During the 90's, there has been a growing interest in the applications of PET in oncology related to the use of a glucose analog (FDG) labeled with the positron emitter 18 F. This tracer of the glucose metabolism is trapped in the cancer cells characterized by a deregulated glycolytic activity. This allows detecting tumors and metastases. The interest of PET in oncology has lead to develop imaging systems and protocols to perform whole-body acquisitions of the patient. Whole-body PET imaging has been limited in practice by the high level of statistical noise that affects the detection of small lesions due to limited radioactive dose injected to the patient and short acquisition time. In this context, our work focused on the optimization of detection performances in whole-body 18 F-FDG PET images. We have first developed an original method to evaluate detectability based on the psychophysical approach of the ROC methodology and adapted to the specificity of whole-body PET images. This method was used to evaluate detection performances of different reconstruction algorithms used for whole-body imaging. We have also studied the influence of the acquisition mode, namely the 2D and the 3D modes. To that purpose, we have used the NEC index to select relevant statistical acquisition conditions in both acquisition modes as a function of the injected dose to the patient. Then, we have compared the detection performances of these different acquisition conditions based on our psychophysical evaluation technique. (author) [fr

  2. Effect of maintenance oral theophylline on dipyridamole-thallium-201 myocardial imaging using SPECT and dipyridamole-induced hemodynamic changes

    International Nuclear Information System (INIS)

    Daley, P.J.; Mahn, T.H.; Zielonka, J.S.; Krubsack, A.J.; Akhtar, R.; Bamrah, V.S.

    1988-01-01

    To evaluate the effect of maintenance oral theophylline therapy on the diagnostic efficacy of dipyridamole-thallium-201 single photon emission computed tomography (SPECT) imaging for coronary artery disease, dipyridamole-thallium-201 SPECT imaging was performed in eight men with documented coronary artery disease before initiation of theophylline treatment and repeated while these patients were receiving therapeutic doses of oral theophylline. Before theophylline treatment, intravenous dipyridamole caused a significant increase in heart rate, decrease in blood pressure, angina in seven of eight patients, and ST segment depression in four of eight patients. While they were being treated with theophylline, none of the patients had angina or ST segment depression, and there were no hemodynamic changes with intravenous dipyridamole. Before theophylline treatment, dipyridamole-thallium-201 SPECT imaging showed reversible perfusion defects in myocardial segments supplied by stenotic coronary arteries. With theophylline treatment, dipyridamole-thallium-201 SPECT showed total absence of reversible perfusion defects. Treatment with theophylline markedly reduced the diagnostic accuracy of dipyridamole-thallium-201 imaging for coronary artery disease

  3. Evaluation of thallium-201 imaging in nontransmural ischemia and infarction

    International Nuclear Information System (INIS)

    Haidar, B.; Oldewurtel, H.A.; Moschos, C.B.; Lee, W.K.; Regan, T.J.

    1981-01-01

    To assess the validity of thallium-201 myocardial imaging in the diagnosis of nontransmural ischemia and infarction, the proximal left anterior descending coronary artery was partially occluded for 60 minutes with a balloon-tip catheter in intact anesthetized dogs in a basal state or during atrial pacing. In vivo scintigrams of myocardium were compared with those obtained in the isolated heart and in the incised ventricle spread flat. None of the animals with partial occlusion with or without pacing demonstrated abnormal scintiscans in vivo. Removal of background by isolating the heart increased positive images to 30%; positive images were associated with an isotope count ratio between ischemic and normal muscle of less than 0.67. Removal of superimposed nonischemic muscle in the heart enface increased image detection after pacing to 11 of 15. Since animals with subendocardial scar failed to demonstrate a cold area in vivo, unfavorable geometry as well as extent and degree of ischemia appear to be important. Thus, thallium radioactivity in superimposed and adjacent myocardium, as well as background, may limit the detection of nontransmural ischemia and scar

  4. Generalized whole-body Patlak parametric imaging for enhanced quantification in clinical PET

    NARCIS (Netherlands)

    Karakatsanis, Nicolas A.; Zhou, Yun; Lodge, Martin A.; Casey, Michael E.; Wahl, Richard L.; Zaidi, Habib; Rahmim, Arman

    2015-01-01

    We recently developed a dynamic multi-bed PET data acquisition framework to translate the quantitative benefits of Patlak voxel-wise analysis to the domain of routine clinical whole-body (WB) imaging. The standard Patlak (sPatlak) linear graphical analysis assumes irreversible PET tracer uptake,

  5. Usefulness of Ga-67 citrate whole body imaging, chest spot imaging, and chest SPECT in sarcoidosis

    International Nuclear Information System (INIS)

    Ueno, Kyoichi; Nishi, Koichi; Namura, Masanobu; Kawashima, Yoshio; Kurumaya, Hiroshi

    1999-01-01

    To assess the sensitivity, and the relative role of Ga-67 whole body, chest spot imaging, and chest SPECT, we retrospectively studied 34 cases of sarcoidosis (24 biopsy proven, 10 clinically diagnosed) with Ga-67 (111 MBq), and compared the results of lung (25 cases), muscle (25 cases), skin (3 cases), and myocardial (2 cases) biopsies. Ga-67 chest SPECT (single photon emission CT) were done in 17 cases with Siemens MultiSPECT3. Ga-67 planar imaging visualized only 2 of 12 (16.7%) lung biopsy-positive cases, 5 of 12 (41.6%) muscle biopsy-positive cases, 2 of 3 (66.7%) skin biopsy-positive cases. However, Ga-67 imaging revealed the lesions in 1 of 9 (11.1%) of muscle biopsy-negative cases, in 2 of 3 (66.7%) of skin biopsy-negative cases, and in 1 of 2 myocardial biopsy-negative cases. Ga-67 chest SPECT visualized 14 hilar lymphadenopathy (LN), 3 supraclavicular LN, and 1 myocardial sarcoidosis. Although both SPECT, and planar spot imaging detected the lesions equally, the former showed them more clearly. Compared with various biopsies, the sensitivity of Ga-67 imaging was not so high. However, Ga-67 imaging is non-invasive, easy to perform the whole body imaging, and can detect the activity of the lesions. Ga-67 SPECT showed clear imaging of the hilar, mediastinal LN, and potentially fatal myocardial sarcoidosis. (author)

  6. Cryo-sectioning of mice for whole-body imaging of drugs and metabolites with desorption electrospray ionization mass spectrometry imaging - a simplified approach.

    Science.gov (United States)

    Okutan, Seda; Hansen, Harald S; Janfelt, Christian

    2016-06-01

    A method is presented for whole-body imaging of drugs and metabolites in mice with desorption electrospray ionization mass spectrometry imaging (DESI-MSI). Unlike most previous approaches to whole-body imaging which are based on cryo-sectioning using a cryo-macrotome, the presented approach is based on use of the cryo-microtome which is found in any histology lab. The tissue sections are collected on tape which is analyzed directly by DESI-MSI. The method is demonstrated on mice which have been dosed intraperitoneally with the antidepressive drug amitriptyline. By combining full-scan detection with the more selective and sensitive MS/MS detection, a number of endogenous compounds (lipids) were imaged simultaneously with the drug and one of its metabolites. The sensitivity of this approach allowed for imaging of drug and the metabolite in a mouse dosed with 2.7 mg amitriptyline per kg bodyweight which is comparable to the normal prescribed human dose. The simultaneous imaging of endogenous and exogenous compounds facilitates registration of the drug images to certain organs in the body by colored-overlay of the two types of images. The method represents a relatively low-cost approach to simple, sensitive and highly selective whole-body imaging in drug distribution and metabolism studies. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Prognostic value of thallium-201 myocardial perfusion imaging in patients with unstable angina who respond to medical treatment

    International Nuclear Information System (INIS)

    Brown, K.A.

    1991-01-01

    Although the prognostic value of thallium-201 imaging is well established, its ability to risk stratify patients who present with unstable angina is unclear. Fifty-two consecutive patients admitted with unstable angina who responded to medical treatment and underwent stress thallium-201 imaging within 1 week of discharge were studied. Patients were followed up for 39 +/- 11 months. Cardiac events included cardiac death (n = 3), nonfatal myocardial infarction (n = 4) and admission for unstable angina or revascularization (n = 17). The ability of thallium-201 data (redistribution, fixed defects, normal) to predict cardiac events was compared with clinical data (age, gender, prior myocardial infarction, anginal syndrome, rest and stress electrocardiogram) and cardiac catheterization data using logistic regression. Thallium-201 redistribution was the only significant predictor of cardiac death or nonfatal myocardial infarction (p less than 0.05). The number of myocardial segments with thallium-201 redistribution (p less than 0.0005) and a history of prior myocardial infarction (p less than 0.05) were the only significant predictors of all cardiac events. Cardiac death or nonfatal myocardial infarction occurred more frequently in patients with thallium-201 redistribution (6 [26%] of 23) than in those without redistribution (1 [3%] of 29, p less than 0.05). Similarly, total cardiac events developed more frequently in patients with thallium-201 redistribution (p less than 0.001). Stress thallium-201 imaging has important prognostic value in patients admitted with unstable angina who respond to medical therapy and can identify subgroups at high versus low risk for future cardiac events

  8. Transient mitral regurgitation: An adjunctive sign of myocardial ischemia during dipyridamole-thallium imaging

    International Nuclear Information System (INIS)

    Lette, J.; Gagnon, A.; Lapointe, J.; Cerino, M.

    1989-01-01

    A patient developed transient exacerbation of a mitral insufficiency murmur and a reversible posterior wall perfusion defect during dipyridamole-thallium imaging. Coronary angiography showed significant stenoses of both the right and the circumflex coronary arteries that supply the posterior papillary muscle. Cardiac auscultation for transient mitral incompetence, a sign of reversible papillary muscle dysfunction, is a simple and practical adjunctive test for myocardial ischemia during dipyridamole-thallium imaging. It may confirm that an isolated reversible posterior wall myocardial perfusion defect is truly ischemic in nature as opposed to an artifact resulting from attenuation by the diaphragm

  9. Prognostic value of intravenous dipyridamole thallium imaging in patients with diabetes mellitus considered for renal transplantation

    International Nuclear Information System (INIS)

    Camp, A.D.; Garvin, P.J.; Hoff, J.; Marsh, J.; Byers, S.L.; Chaitman, B.R.

    1990-01-01

    Patients with diabetes and end-stage renal failure are known to have a high risk for cardiac morbidity and mortality associated with renal transplantation. The most efficient method to determine preoperative cardiac risk has not been established. To determine the effectiveness of intravenous dipyridamole thallium imaging in predicting cardiac events, 40 diabetic renal transplant candidates were studied preoperatively in a prospective trial. The study group consisted of 40 patients whose average age was 42 years (range 27 to 64); 34 (85%) were hypertensive and 21 (53%) were cigarette smokers. Cardiac history included chest pain in 6 patients and prior myocardial infarction in 3 patients. Dipyridamole thallium imaging showed reversible defects in 9 patients, fixed defects in 8 patients and normal scans in 23 patients. Dipyridamole thallium imaging was performed using 0.56 mg/kg of dipyridamole infused intravenously over 4 minutes. Cardiac events occurred only in patients with reversible thallium defects, of which there were 6. Of these 6 patients, 3 had cardiac events before transplantation and 3 had them in the early postoperative phase (within 6 weeks of surgery). Of 21 patients who underwent renal transplantation, 3 had cardiac events within 6 weeks of transplantation. The average duration of follow-up was 11 months (range 1 to 21). Thus, dipyridamole thallium imaging is an effective method of identifying renal transplant candidates likely to develop cardiac complications. Routine coronary angiography may not be necessary to screen all renal transplant candidates for coronary artery disease before surgery

  10. Factors affecting gastric uptake in whole body FDG-PET imaging

    International Nuclear Information System (INIS)

    Tomemori, Takashi; Kitagawa, Mami; Nakahara, Tadaki; Wu, Jin; Nakagawa, Keiichi; Uno, Kimiichi; Abe, Kinji; Tomiyoshi, Katsumi

    2001-01-01

    Positron emission tomography (PET) using 2-deoxy-2-[ 18 F]-fluoro-D-glucose (FDG) is very useful for the detection and staging of tumors. However, FDG is also accumulated in the normal tissues in various degrees. This physiological FDG uptake is often seen in intestine, making confusion with malignant tumor. The aim of this study was to identify factors influencing physiological FDG uptake in the stomach. A total of 136 people who underwent cancer screening or staging of tumors except for gastric cancer using FDG whole-body PET was examined (mean age: 55.6 yrs). All subjects fasted for at least 4 hours before the PET study and were administrated with FDG intravenously (mean FDG dose: 308.9 MBq). Emission images were acquired on a whole-body PET scanner and images were reconstructed without attenuation correction. The intensity of gastric uptake of FDG whole-body PET image was visually classified into 3 grades; grade 2 = the intensity of gastric uptake more than pulmonary uptake, grade 1 = the intensity of gastric uptake equal to or less than pulmonary uptake, grade 0 = no contrast between gastric uptake and background. Twenty-eight subjects (20.6%) were classified into grade 2, 42 subjects (30.9%) were grade 1 and 66 subjects (48.5%) were grade 0. Subjects' age, fasting time, FDG dose, serum glucose level, free fatty acid level and insulin level were not significantly correlated with the intensity of gastric uptake. But the subjects with higher gastric uptake tended to have anti-Helicobactor pylori (H. pylori) antibodies. The rate of having anti-H.pylori antibodies in the grade 2 group is significantly higher than the grade 1 group (85.7% vs. 72.5%, p<0.05), and that of the grade 1 group is significantly higher than the grade 0 group (72.5% vs. 42.2%, p<0.01). Gastric uptake was observed in about half of subjects. Especially, approximately 20% of all showed high gastric uptake, which was associated with H.pylori infection. Therefore, most of the subjects with high

  11. Factors affecting gastric uptake in whole body FDG-PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tomemori, Takashi; Kitagawa, Mami; Nakahara, Tadaki; Wu, Jin; Nakagawa, Keiichi; Uno, Kimiichi; Abe, Kinji; Tomiyoshi, Katsumi [Nishidai Clinic Diagnostic Imaging Center, Tokyo (Japan)

    2001-06-01

    Positron emission tomography (PET) using 2-deoxy-2-[{sup 18}F]-fluoro-D-glucose (FDG) is very useful for the detection and staging of tumors. However, FDG is also accumulated in the normal tissues in various degrees. This physiological FDG uptake is often seen in intestine, making confusion with malignant tumor. The aim of this study was to identify factors influencing physiological FDG uptake in the stomach. A total of 136 people who underwent cancer screening or staging of tumors except for gastric cancer using FDG whole-body PET was examined (mean age: 55.6 yrs). All subjects fasted for at least 4 hours before the PET study and were administrated with FDG intravenously (mean FDG dose: 308.9 MBq). Emission images were acquired on a whole-body PET scanner and images were reconstructed without attenuation correction. The intensity of gastric uptake of FDG whole-body PET image was visually classified into 3 grades; grade 2 = the intensity of gastric uptake more than pulmonary uptake, grade 1 = the intensity of gastric uptake equal to or less than pulmonary uptake, grade 0 = no contrast between gastric uptake and background. Twenty-eight subjects (20.6%) were classified into grade 2, 42 subjects (30.9%) were grade 1 and 66 subjects (48.5%) were grade 0. Subjects' age, fasting time, FDG dose, serum glucose level, free fatty acid level and insulin level were not significantly correlated with the intensity of gastric uptake. But the subjects with higher gastric uptake tended to have anti-Helicobactor pylori (H. pylori) antibodies. The rate of having anti-H.pylori antibodies in the grade 2 group is significantly higher than the grade 1 group (85.7% vs. 72.5%, p<0.05), and that of the grade 1 group is significantly higher than the grade 0 group (72.5% vs. 42.2%, p<0.01). Gastric uptake was observed in about half of subjects. Especially, approximately 20% of all showed high gastric uptake, which was associated with H.pylori infection. Therefore, most of the subjects

  12. Computational anatomy based on whole body imaging basic principles of computer-assisted diagnosis and therapy

    CERN Document Server

    Masutani, Yoshitaka

    2017-01-01

    This book deals with computational anatomy, an emerging discipline recognized in medical science as a derivative of conventional anatomy. It is also a completely new research area on the boundaries of several sciences and technologies, such as medical imaging, computer vision, and applied mathematics. Computational Anatomy Based on Whole Body Imaging highlights the underlying principles, basic theories, and fundamental techniques in computational anatomy, which are derived from conventional anatomy, medical imaging, computer vision, and applied mathematics, in addition to various examples of applications in clinical data. The book will cover topics on the basics and applications of the new discipline. Drawing from areas in multidisciplinary fields, it provides comprehensive, integrated coverage of innovative approaches to computational anatomy. As well,Computational Anatomy Based on Whole Body Imaging serves as a valuable resource for researchers including graduate students in the field and a connection with ...

  13. Whole body scan system based on γ camera

    International Nuclear Information System (INIS)

    Ma Tianyu; Jin Yongjie

    2001-01-01

    Most existing domestic γ cameras can not perform whole body scan protocol, which is of important use in clinic. The authors designed a set of whole body scan system, which is made up of a scan bed, an ISA interface card controlling the scan bed and the data acquisition software based on a data acquisition and image processing system for γ cameras. The image was obtained in clinical experiment, and the authors think it meets the need of clinical diagnosis. Application of this system in γ cameras can provide whole body scan function at low cost

  14. Compact whole-body fluorescent imaging of nude mice bearing EGFP expressing tumor

    Science.gov (United States)

    Chen, Yanping; Xiong, Tao; Chu, Jun; Yu, Li; Zeng, Shaoqun; Luo, Qingming

    2005-01-01

    Issue of tumor has been a hotspot of current medicine. It is important for tumor research to detect tumors bearing in animal models easily, fast, repetitively and noninvasivly. Many researchers have paid their increasing interests on the detecting. Some contrast agents, such as green fluorescent protein (GFP) and Discosoma red fluorescent protein (Dsred) were applied to enhance image quality. Three main kinds of imaging scheme were adopted to visualize fluorescent protein expressing tumors in vivo. These schemes based on fluorescence stereo microscope, cooled charge-coupled-device (CCD) or camera as imaging set, and laser or mercury lamp as excitation light source. Fluorescence stereo microscope, laser and cooled CCD are expensive to many institutes. The authors set up an inexpensive compact whole-body fluorescent imaging tool, which consisted of a Kodak digital camera (model DC290), fluorescence filters(B and G2;HB Optical, Shenyang, Liaoning, P.R. China) and a mercury 50-W lamp power supply (U-LH50HG;Olympus Optical, Japan) as excitation light source. The EGFP was excited directly by mercury lamp with D455/70 nm band-pass filter and fluorescence was recorded by digital camera with 520nm long-pass filter. By this easy operation tool, the authors imaged, in real time, fluorescent tumors growing in live mice. The imaging system is external and noninvasive. For half a year our experiments suggested the imaging scheme was feasible. Whole-body fluorescence optical imaging for fluorescent expressing tumors in nude mouse is an ideal tool for antitumor, antimetastatic, and antiangiogenesis drug screening.

  15. Thallium-201 myocardial perfusion imaging during transient coronary occlusion at the time of PTCA

    International Nuclear Information System (INIS)

    Nakagawa, Tatsuya; Sugihara, Hiroki; Inagaki, Suetsugu

    1989-01-01

    To evaluate myocardial perfusion during transient coronary arterial occlusion, thallium-201 was administered intravenously during percutaneous transluminall coronary angioplasty (PTCA) in 12 patients with effort angina, and the resulting perfusion images were compared with those of exercise stress obtained before PTCA. Thallium-201 was injected at the last inflation of an angioplastic baloon and occlusion was maintained for 60 to 90 sec. Three projections of planar images were obtained immediately after PTCA, using a portable gamma camera in an angiography room. These perfusion images obtained during PTCA and exercise were visually interpreted and compared. Myocardial perfusion defects due to the responsible vessel occlusion were observed at early imaging after PTCA, and were fully redistributed three hrs post injection. In 10 patients without angiographically imaged collateral vessels, there were no significatn differences in perfusion between images during PTCA and during exercise. Two patients whose collaterals were observed during coronary angiography before PTCA had higher perfusion scores during PTCA than during exercise. We concluded that intravenous injection of thallium-201 during PTCA is a useful means for assessing alteration of myocardial perfusion due to transient coronary occlusion without increasing the risk of angioplastic procedures, and that it provides more precise information about the jeopardized myocardium, perfused by antegrade blood flow. (author)

  16. Dynamic whole body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application

    Science.gov (United States)

    Karakatsanis, Nicolas A.; Lodge, Martin A.; Tahari, Abdel K.; Zhou, Y.; Wahl, Richard L.; Rahmim, Arman

    2013-01-01

    Static whole body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single bed-coverage limiting the axial field-of-view to ~15–20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole body PET acquisition protocol of ~45min total length is presented, composed of (i) an initial 6-min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (6 passes x 7 bed positions, each scanned for 45sec). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares (OLS) Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of 10 different clinically

  17. Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application.

    Science.gov (United States)

    Karakatsanis, Nicolas A; Lodge, Martin A; Tahari, Abdel K; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-10-21

    Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ~15-20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ~45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different clinically

  18. Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application

    International Nuclear Information System (INIS)

    Karakatsanis, Nicolas A; Lodge, Martin A; Tahari, Abdel K; Zhou, Y; Wahl, Richard L; Rahmim, Arman

    2013-01-01

    Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ∼15–20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ∼45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate K i and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different

  19. Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application

    Science.gov (United States)

    Karakatsanis, Nicolas A.; Lodge, Martin A.; Tahari, Abdel K.; Zhou, Y.; Wahl, Richard L.; Rahmim, Arman

    2013-10-01

    Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ˜15-20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ˜45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different clinically

  20. Dipyridamole thallium imaging for detecting cardiac involvement in patients with systemic sclerosis (scleroderma)

    Energy Technology Data Exchange (ETDEWEB)

    Ishida, Yoshio; Matsubara, Noboru; Tani, Akihiro; Morozumi, Takakazu; Hori, Masatsugu; Kitabatake, Akira; Kamada, Takenobu; Kimura, Kazufumi; Kozuka, Takahiro (Osaka Univ. (Japan). Faculty of Medicine)

    1990-02-01

    Dipyridamole thallium-201 imaging was carried out in 21 patients with progressive systemic sclerosis (PSS) to assess its value in detecting impaired myocardium and coronary microcirculation associated with PSS. Depending upon the degree of cardiac function, the patients were classified as having either ejection fraction of 50% or more (Group I, n=17) or less than 50% (Group II, n=4). In Group I, four patients had transient defect in which perfusion defects were seen on early images but not seen on delayed images; three had reverse redistribution in which defects were not seen on early images but seen on delayed images; and three had persistent defects which were seen on both early and delayed images. A decreased washout of thallium-201 was seen in 9 patients. In an analysis of both perfusion defects and washout rate, 13 patients (76%) in Group I were found to have abnormal findings. This suggests that disturbed coronary microcirculation or impaired myocardium may frequently develop even when EF is normal. All of the patients categorized as having a decreased cardiac function (Group II) had perfusion defect, suggesting the presence of myocardial fibrosis. In PSS, deterioration of cardiac function seemed to be associated with progression of myocardial fibrosis. Dipyridamole thallium imaging may be a sensitive method for detecting cardiac lesions in PSS. It also has the potential for detecting decreased coronary flow reserve or slightly impaired myocardium even without decreased EF. (N.K.).

  1. Automated analysis of whole skeletal muscle for muscular atrophy detection of ALS in whole-body CT images: preliminary study

    Science.gov (United States)

    Kamiya, Naoki; Ieda, Kosuke; Zhou, Xiangrong; Yamada, Megumi; Kato, Hiroki; Muramatsu, Chisako; Hara, Takeshi; Miyoshi, Toshiharu; Inuzuka, Takashi; Matsuo, Masayuki; Fujita, Hiroshi

    2017-03-01

    Amyotrophic lateral sclerosis (ALS) causes functional disorders such as difficulty in breathing and swallowing through the atrophy of voluntary muscles. ALS in its early stages is difficult to diagnose because of the difficulty in differentiating it from other muscular diseases. In addition, image inspection methods for aggressive diagnosis for ALS have not yet been established. The purpose of this study is to develop an automatic analysis system of the whole skeletal muscle to support the early differential diagnosis of ALS using whole-body CT images. In this study, the muscular atrophy parts including ALS patients are automatically identified by recognizing and segmenting whole skeletal muscle in the preliminary steps. First, the skeleton is identified by its gray value information. Second, the initial area of the body cavity is recognized by the deformation of the thoracic cavity based on the anatomical segmented skeleton. Third, the abdominal cavity boundary is recognized using ABM for precisely recognizing the body cavity. The body cavity is precisely recognized by non-rigid registration method based on the reference points of the abdominal cavity boundary. Fourth, the whole skeletal muscle is recognized by excluding the skeleton, the body cavity, and the subcutaneous fat. Additionally, the areas of muscular atrophy including ALS patients are automatically identified by comparison of the muscle mass. The experiments were carried out for ten cases with abnormality in the skeletal muscle. Global recognition and segmentation of the whole skeletal muscle were well realized in eight cases. Moreover, the areas of muscular atrophy including ALS patients were well identified in the lower limbs. As a result, this study indicated the basic technology to detect the muscle atrophy including ALS. In the future, it will be necessary to consider methods to differentiate other kinds of muscular atrophy as well as the clinical application of this detection method for early ALS

  2. The pacing stress test: thallium-201 myocardial imaging after atrial pacing. Diagnostic value in detecting coronary artery disease compared with exercise testing

    International Nuclear Information System (INIS)

    Heller, G.V.; Aroesty, J.M.; Parker, J.A.; McKay, R.G.; Silverman, K.J.; Als, A.V.; Come, P.C.; Kolodny, G.M.; Grossman, W.

    1984-01-01

    Many patients suspected of having coronary artery disease are unable to undergo adequate exercise testing. An alternate stress, pacing tachycardia, has been shown to produce electrocardiographic changes that are as sensitive and specific as those observed during exercise testing. To compare thallium-201 imaging after atrial pacing stress with thallium imaging after exercise stress, 22 patients undergoing cardiac catheterization were studied with both standard exercise thallium imaging and pacing thallium imaging. Positive ischemic electrocardiographic changes (greater than 1 mm ST segment depression) were noted in 11 of 16 patients with coronary artery disease during exercise, and in 15 of the 16 patients during atrial pacing. One of six patients with normal or trivial coronary artery disease had a positive electrocardiogram with each test. Exercise thallium imaging was positive in 13 of 16 patients with coronary artery disease compared with 15 of 16 patients during atrial pacing. Three of six patients without coronary artery disease had a positive scan with exercise testing, and two of these same patients developed a positive scan with atrial pacing. Of those patients with coronary artery disease and an abnormal scan, 85% showed redistribution with exercise testing compared with 87% during atrial pacing. Segment by segment comparison of thallium imaging after either atrial pacing or exercise showed that there was a good correlation of the location and severity of the thallium defects (r . 0.83, p . 0.0001, Spearman rank correlation). It is concluded that the location and presence of both fixed and transient thallium defects after atrial pacing are closely correlated with the findings after exercise testing

  3. Diabetes mellitus: long-term prognostic value of whole-body MR imaging for the occurrence of cardiac and cerebrovascular events.

    Science.gov (United States)

    Bamberg, Fabian; Parhofer, Klaus G; Lochner, Elena; Marcus, Roy P; Theisen, Daniel; Findeisen, Hannes M; Hoffmann, Udo; Schönberg, Stefan O; Schlett, Christopher L; Reiser, Maximilian F; Weckbach, Sabine

    2013-12-01

    To study the predictive value of whole-body magnetic resonance (MR) imaging for the occurrence of cardiac and cerebrovascular events in a cohort of patients with diabetes mellitus (DM). This HIPAA-compliant study was approved by the institutional review board. Informed consent was obtained from all patients before enrollment into the study. The authors followed up 65 patients with DM (types 1 and 2) who underwent a comprehensive, contrast material-enhanced whole-body MR imaging protocol, including brain, cardiac, and vascular sequences at baseline. Follow-up was performed by phone interview. The primary endpoint was a major adverse cardiac and cerebrovascular event (MACCE), which was defined as composite cardiac-cerebrovascular death, myocardial infarction, cerebrovascular event, or revascularization. MR images were assessed for the presence of systemic atherosclerotic vessel changes, white matter lesions, and myocardial changes. Kaplan-Meier survival and Cox regression analyses were performed to determine associations. Follow-up was completed in 61 patients (94%; median age, 67.5 years; 30 women [49%]; median follow-up, 70 months); 14 of the 61 patients (23%) experienced MACCE. Although normal whole-body MR imaging excluded MACCE during the follow-up period (0%; 95% confidence interval [CI]: 0%, 17%), any detectable ischemic and/or atherosclerotic changes at whole-body MR imaging (prevalence, 66%) conferred a cumulative event rate of 20% at 3 years and 35% at 6 years. Whole-body MR imaging summary estimate of disease was strongly predictive for MACCE (one increment of vessel score and each territory with atherosclerotic changes: hazard ratio, 13.2 [95% CI: 4.5, 40.1] and 3.9 [95% CI: 2.2, 7.5], respectively), also beyond clinical characteristics as well as individual cardiac or cerebrovascular MR findings. These initial data indicate that disease burden as assessed with whole-body MR imaging confers strong prognostic information in patients with DM. Online

  4. Whole body MRI in children; Ganzkoerper-MRT bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Schaefer, Juergen F.; Tsiflikas, Ilias [Tuebingen Univ. (Germany). Bereich Kinderradiologie

    2014-09-15

    In pediatric patients whole body MRI has a relevant impact on both, diagnostic work-up and treatment. Using adapted sequence protocols comprehensive imaging without radiation exposure is possible avoiding additional examinations in many cases. Especially in bone marrow the differentiation between normal and abnormal finding can be difficult, therefore the knowledge of normal maturing of organs is important. Whole body diffusion weighted imaging particularly in neuroblastomas or sarcomas improves the low specificity of conventional MR-protocols. Technical prerequisites, examination protocol and strategies, image interpretation, indications and clinical relevance as well as advantages and disadvantages of whole body MRI will be discussed on the basis of application-oriented cases and the literature.

  5. Whole-body direct 4D parametric PET imaging employing nested generalized Patlak expectation-maximization reconstruction

    NARCIS (Netherlands)

    Karakatsanis, Nicolas A.; Casey, Michael E.; Lodge, Martin A.; Rahmim, Arman; Zaidi, Habib

    2016-01-01

    Whole-body (WB) dynamic PET has recently demonstrated its potential in translating the quantitative benefits of parametric imaging to the clinic. Post-reconstruction standard Patlak (sPatlak) WB graphical analysis utilizes multi-bed multi-pass PET acquisition to produce quantitative WB images of the

  6. Intracoronary thallium-201 scintigraphy after thrombolytic therapy for acute myocardial infarction compared with 10 and 100 day intravenous thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Heller, G.V.; Parker, J.A.; Silverman, K.J.; Royal, H.D.; Kolodny, G.M.; Paulin, S.; Braunwald, E.; Markis, J.E.

    1987-01-01

    Thallium-201 imaging has been utilized to estimate myocardial salvage after thrombolytic therapy for acute myocardial infarction. However, results from recent animal studies have suggested that as a result of reactive hyperemia and delayed necrosis, thallium-201 imaging may overestimate myocardial salvage. To determine whether early overestimation of salvage occurs in humans, intracoronary thallium-201 scans 1 hour after thrombolytic therapy were compared with intravenous thallium-201 scans obtained approximately 10 and 100 days after myocardial infarction in 29 patients. In 10 patients with angiographic evidence of coronary reperfusion, immediate improvement in thallium defects and no interim clinical events, there was no change in imaging in the follow-up studies. Of nine patients with coronary reperfusion but no initial improvement of perfusion defects, none showed worsening of defects in the follow-up images. Six of these patients demonstrated subsequent improvement at either 10 or 100 days after infarction. Seven of 10 patients with neither early evidence of reperfusion nor improvement in perfusion defects had improvement of infarct-related perfusion defects, and none showed worsening. In conclusion, serial scanning at 10 and 100 days after infarction in patients with no subsequent clinical events showed no worsening of the perfusion image compared with images obtained in acute studies. Therefore, there is no evidence that thallium-201 imaging performed early in patients with acute myocardial infarction overestimates improvement

  7. Multisite Thrombus Imaging and Fibrin Content Estimation With a Single Whole-Body PET Scan in Rats.

    Science.gov (United States)

    Blasi, Francesco; Oliveira, Bruno L; Rietz, Tyson A; Rotile, Nicholas J; Naha, Pratap C; Cormode, David P; Izquierdo-Garcia, David; Catana, Ciprian; Caravan, Peter

    2015-10-01

    Thrombosis is a leading cause of morbidity and mortality worldwide. Current diagnostic strategies rely on imaging modalities that are specific for distinct vascular territories, but a thrombus-specific whole-body imaging approach is still missing. Moreover, imaging techniques to assess thrombus composition are underdeveloped, although therapeutic strategies may benefit from such technology. Therefore, our goal was to test whether positron emission tomography (PET) with the fibrin-binding probe (64)Cu-FBP8 allows multisite thrombus detection and fibrin content estimation. Thrombosis was induced in Sprague-Dawley rats (n=32) by ferric chloride application on both carotid artery and femoral vein. (64)Cu-FBP8-PET/CT imaging was performed 1, 3, or 7 days after thrombosis to detect thrombus location and to evaluate age-dependent changes in target uptake. Ex vivo biodistribution, autoradiography, and histopathology were performed to validate imaging results. Arterial and venous thrombi were localized on fused PET/CT images with high accuracy (97.6%; 95% confidence interval, 92-100). A single whole-body PET/MR imaging session was sufficient to reveal the location of both arterial and venous thrombi after (64)Cu-FBP8 administration. PET imaging showed that probe uptake was greater in younger clots than in older ones for both arterial and venous thrombosis (P<0.0001). Quantitative histopathology revealed an age-dependent reduction of thrombus fibrin content (P<0.001), consistent with PET results. Biodistribution and autoradiography further confirmed the imaging findings. We demonstrated that (64)Cu-FBP8-PET is a feasible approach for whole-body thrombus detection and that molecular imaging of fibrin can provide, noninvasively, insight into clot composition. © 2015 American Heart Association, Inc.

  8. Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics

    DEFF Research Database (Denmark)

    Maroy, Renaud; Boisgard, Raphaël; Comtat, Claude

    2008-01-01

    Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new...... method for the segmentation of rodent whole-body PET images that takes these two difficulties into account by estimating the pharmacokinetics far from organ borders. The segmentation method proved efficient on whole-body numerical rat phantom simulations, including 3-14 organs, together...

  9. Arm exercise-thallium imaging testing for the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Balady, G.J.; Weiner, D.A.; Rothendler, J.A.; Ryan, T.J.

    1987-01-01

    Patients with lower limb impairment are often unable to undergo a standard bicycle or treadmill test for the evaluation of coronary artery disease. To establish an alternative method of testing, 50 subjects (aged 56 +/- 10 years) performed arm ergometry testing in conjunction with myocardial thallium scintigraphy. All underwent coronary angiography; significant coronary artery disease (greater than or equal to 70% stenosis) in at least one vessel was present in 41 (82%) of the 50 patients. Thallium scintigraphy was found to have an 83% sensitivity and 78% specificity for detecting coronary disease, compared with a sensitivity and specificity of 54% (p less than 0.01) and 67% (p = NS), respectively, for exercise electrocardiography. In the subgroup of 23 patients who had no prior myocardial infarction or left bundle branch block and were not taking digitalis, thallium scintigraphy had a sensitivity of 80% versus 50% for exercise electrocardiography. Scintigraphy yielded a sensitivity of 84, 74 and 90% for one, two and three vessel disease, respectively. Noninvasive arm ergometry exercise-thallium imaging testing appears to be reliable and useful and should be considered in the evaluation of coronary artery disease in patients with lower limb impairment

  10. The role of embodied simulation in mental transformation of whole-body images: evidence from Parkinson's disease.

    Science.gov (United States)

    Conson, Massimiliano; Trojano, Luigi; Vitale, Carmine; Mazzarella, Elisabetta; Allocca, Roberto; Barone, Paolo; Grossi, Dario; Santangelo, Gabriella

    2014-02-01

    It has been repeatedly demonstrated that mentally performing an action and mentally transforming body-parts entail simulation of one's own body movements, consistent with predictions of embodied cognition theories. However, the involvement of embodied simulation in mental transformation of whole-body images is still disputed. Here, we assessed own body transformation in Parkinson's disease (PD) patients with symptoms most affecting the left or the right body side. PD patients were required to perform left-right judgments on front-facing or back-facing human figures, and a letter rotation task. Results demonstrated that PD patients were selectively impaired in judging the side of back-facing human figures corresponding to their own most affected side, but performed as well as healthy subjects on mental transformation of front-facing bodies and on letter rotation. These findings demonstrate a parallel impairment between motor and mental simulation mechanisms in PD patients, thus highlighting the specific contribution of embodied cognition to mental transformation of whole-body images. Copyright © 2014. Published by Elsevier B.V.

  11. Serial thallium-201 myocardial imaging after dipyridamole infusion: diagnostic utility in detecting coronary stenoses and relationship to regional wall motion

    International Nuclear Information System (INIS)

    Leppo, J.; Boucher, C.A.; Okada, R.D.; Newell, J.B.; Strauss, H.W.; Pohost, G.M.

    1982-01-01

    After a 4-minute i.v. dipyridamole infusion, 0.14 mg/kg/min, serial thallium-201 scans were obtained in 60 patients undergoing cardia catheterization. Forty patients had significant (greater than or equal to50% stenosis) coronary artery disease (CAD), and 20 patients had normal coronary arteries or trivial lesions. The images were graded qualitatively for thallium activity by three observers. Sensitivity was 93% (37 of 40) and specificity was 80% (16 of 20). The sensitivity and specificity of the thallium-201 study were not affected by the extent of CAD, the presence of Q waves, or propranolol therapy. Twenty-seven of 37 patients who had initial defects (73%) had complete thallium redistribution of one or more defects. Patient-by-patient anlaysis using a regression model of all patients showed that the fate of a segmental thallium defect predicted abnormal wall motion by angiography better than ECG Q waves. The presence of propranolol therapy or collaterals did not significantly affect the thallium redistribution results. It is concluded that qualitative interpretation by multiple observers of thallium images after dipyridamole infusion is a highly sensitive and specific test for CAD. After dipyridamole, as with exercise stress, the extent of thallium redistribution is related to the degree of myocardial wall motion abnormality

  12. Application of semiquantitative analysis of whole body bone imaging on distal femoral metaphysis osseous metastasis of neuroblastoma

    International Nuclear Information System (INIS)

    Liu Yang; Wang Huixiang; Zhou Tao

    2012-01-01

    Objective: To evaluate the value of semiquantitative analysis of whole body bone imaging on distal femoral metaphysis osseous metastasis of neuroblastoma. Methods: Twenty-nine patients with confirmed neuroblastoma by pathological reports were divided into group of metastasis and group of no metastasis by bone marrow slides, X-ray, CT, MRI or clinical follow-up. Whole body bone imaging was performed pre-or postoperation. All cases were analysed by two methods: (1) Semi-quantitative analysis: Regions of interest on bilateral distal femoral metaphysic and middle of femoral were drawn, and their average counts were measured. The ratio of radioactivity of distal femoral metaphysic to middle of femoral was calculated; (2) Visual analysis:Bilateral distal femoral metaphysic metastasis were diagnosed by visual analysis according to whole body bone imaging. The differences between this two methods were compared. Results: There were differences of the ratio of radioactivity of distal femoral metaphysic to middle of femoral between group of metastasis and group of no metastasis (t =8.334, P<0.01), and there was no significant difference between t the two methods (χ 2 =0.68, P>0.05). The sensitivity, specificity, accuracy, positive predictive value and negative predictive value of semiquantitative analysis in detecting osseous metastasis were 90.5% , 95.7% , 94.4% , 86.4% and 97.1% , while visual analysis were 81% , 100% , 95.6% , 100% and 94.5% . Conclusions: Radionuclide whole body bone imaging was of great importance in diagnosis of osseous metastasis of neuroblastoma. The diagnostic accuracy was improved by combination of visual analysis and semi-quantitative analysis. (authors)

  13. [Segmentation of whole body bone SPECT image based on BP neural network].

    Science.gov (United States)

    Zhu, Chunmei; Tian, Lianfang; Chen, Ping; He, Yuanlie; Wang, Lifei; Ye, Guangchun; Mao, Zongyuan

    2007-10-01

    In this paper, BP neural network is used to segment whole body bone SPECT image so that the lesion area can be recognized automatically. For the uncertain characteristics of SPECT images, it is hard to achieve good segmentation result if only the BP neural network is employed. Therefore, the segmentation process is divided into three steps: first, the optimal gray threshold segmentation method is employed for preprocessing, then BP neural network is used to roughly identify the lesions, and finally template match method and symmetry-removing program are adopted to delete the wrongly recognized areas.

  14. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro

    1983-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy. (author)

  15. Evaluation of myocardial involvement in Duchenne progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kawai, Naoki; Yamamoto, Shuhei; Okada, Mitsuhiro (Nagoya Univ. (Japan). Faculty of Medicine)

    1983-12-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. The qualitative analysis was performed in anterior, 3 left anterior oblique and left lateral projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in LV posterolateral or posterior walls (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle changes or thoracic deformities assessed by transmission computed tomography. Slightly increased thallium-201 activity in RV free wall and lungs was shown in nine and one patient, respectively. The extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. The myocardial scintigraphic changes were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies in 2 to 3 years. It was concluded that the thallium myocardial perfusion imaging was a useful clinical technique to evaluate the cardiomyopathy in Duchenne progressive muscular dystrophy.

  16. Exercise thallium-201 imaging in complete left bundle branch block and the prevalence of septal perfusion defects

    International Nuclear Information System (INIS)

    Jazmati, B.; Sadaniantz, A.; Emaus, S.P.; Heller, G.V.

    1991-01-01

    To determine the prevalence of septal defects in a generalized referral population, the records of 93 consecutive patients with complete left bundle branch block (BBB) who underwent symptom-limited treadmill exercise testing with thallium-201 myocardial imaging over a 3-year period were reviewed. Segmental analysis of the planar thallium-201 images was performed in a blinded fashion with agreement by consensus. Computerized quantitative analysis of the images also was independently performed, and was correlated with the visual interpretations. Forty-seven patients (51%) had normal images, and 46 (49%) had defects of greater than or equal to 2 segments. In the abnormal studies, only 13 patients (14% of the total population) had septal defects, while a much higher number of patients, 33 (39%), had inferior or apical defects, or both. Coronary angiography was performed in 6 patients with septal defects: Significant narrowing of the left anterior descending coronary artery was found in 4 patients, a narrowed right coronary artery was found in 1, and normal coronary arteries were seen in the other patient. In conclusion, whereas previous studies have suggested a high percentage of false-positive septal defects in patients with left BBB, this study demonstrates a low prevalence (14%) of septal defects in a large population of unselected patients presenting for exercise thallium-201 imaging. Therefore, exercise thallium-201 imaging remains a useful procedure for evaluating patients with complete left BBB

  17. Metamaterial-based transmit and receive system for whole-body magnetic resonance imaging at ultra-high magnetic fields.

    Science.gov (United States)

    Herrmann, Tim; Liebig, Thorsten; Mallow, Johannes; Bruns, Christian; Stadler, Jörg; Mylius, Judith; Brosch, Michael; Svedja, Jan Taro; Chen, Zhichao; Rennings, Andreas; Scheich, Henning; Plaumann, Markus; Hauser, Marcus J B; Bernarding, Johannes; Erni, Daniel

    2018-01-01

    Magnetic resonance imaging (MRI) at ultra-high fields (UHF), such as 7 T, provides an enhanced signal-to-noise ratio and has led to unprecedented high-resolution anatomic images and brain activation maps. Although a variety of radio frequency (RF) coil architectures have been developed for imaging at UHF conditions, they usually are specialized for small volumes of interests (VoI). So far, whole-body coil resonators are not available for commercial UHF human whole-body MRI systems. The goal of the present study was the development and validation of a transmit and receive system for large VoIs that operates at a 7 T human whole-body MRI system. A Metamaterial Ring Antenna System (MRAS) consisting of several ring antennas was developed, since it allows for the imaging of extended VoIs. Furthermore, the MRAS not only requires lower intensities of the irradiated RF energy, but also provides a more confined and focused injection of excitation energy on selected body parts. The MRAS consisted of several antennas with 50 cm inner diameter, 10 cm width and 0.5 cm depth. The position of the rings was freely adjustable. Conformal resonant right-/left-handed metamaterial was used for each ring antenna with two quadrature feeding ports for RF power. The system was successfully implemented and demonstrated with both a silicone oil and a water-NaCl-isopropanol phantom as well as in vivo by acquiring whole-body images of a crab-eating macaque. The potential for future neuroimaging applications was demonstrated by the acquired high-resolution anatomic images of the macaque's head. Phantom and in vivo measurements of crab-eating macaques provided high-resolution images with large VoIs up to 40 cm in xy-direction and 45 cm in z-direction. The results of this work demonstrate the feasibility of the MRAS system for UHF MRI as proof of principle. The MRAS shows a substantial potential for MR imaging of larger volumes at 7 T UHF. This new technique may provide new diagnostic potential

  18. Radiation exposure in whole body CT screening.

    Science.gov (United States)

    Suresh, Pamidighantam; Ratnam, S V; Rao, K V J

    2011-04-01

    Using a technology that "takes a look" at people's insides and promises early warnings of cancer, cardiac disease, and other abnormalities, clinics and medical imaging facilities nationwide are touting a new service for health conscious people: "Whole body CT screening" this typically involves scanning the body from the chin to below the hips with a form of x-ray imaging that produces cross-sectional images. In USA direct-to-consumer marketing of whole body CT is occurring today in many metropolitan areas. Free standing CT screening centres are being sited in shopping malls and other high density public areas, and these centres are being advertised in the electronic and print media. In this context the present article discussed the pros and cons of having such centres in India with the advent of multislice CT leading to fast scan times.

  19. From whole-body counting to imaging: The computer aided collimation gamma camera project (CACAO)

    Energy Technology Data Exchange (ETDEWEB)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Ballongue, P

    2000-07-01

    Whole-body counting is the method of choice for in vivo detection of contamination. To extend this well established method, the possible advantages of imaging radiocontaminants are examined. The use of the CACAO project is then studied. A comparison of simulated reconstructed images obtained by the CACAO project and by a conventional gamma camera used in nuclear medicine follows. Imaging a radionuclide contaminant with a geometrical sensitivity of 10{sup -2} seems possible in the near future. (author)

  20. From whole-body counting to imaging: The computer aided collimation gamma camera project (CACAO)

    International Nuclear Information System (INIS)

    Jeanguillaume, C.; Begot, S.; Quartuccio, M.; Douiri, A.; Ballongue, P.

    2000-01-01

    Whole-body counting is the method of choice for in vivo detection of contamination. To extend this well established method, the possible advantages of imaging radiocontaminants are examined. The use of the CACAO project is then studied. A comparison of simulated reconstructed images obtained by the CACAO project and by a conventional gamma camera used in nuclear medicine follows. Imaging a radionuclide contaminant with a geometrical sensitivity of 10 -2 seems possible in the near future. (author)

  1. Whole-body MRI using a sliding table and repositioning surface coil approach

    International Nuclear Information System (INIS)

    Takahara, Taro; Kwee, Thomas; Luijten, Peter; Kibune, Satoshi; Ochiai, Reiji; Sakamoto, Tetsuro; Niwa, Tetsu; Van Cauteren, Marc

    2010-01-01

    To introduce and assess a new way of performing whole-body magnetic resonance imaging (MRI) using a non-integrated surface coil approach as available on most clinical MRI systems worldwide. Ten consecutive asymptomatic subjects prospectively underwent whole-body MRI for health screening. Whole-body MRI included T1-, T2- and diffusion-weighted sequences, and was performed using a non-integrated surface coil to image four different stations without patient repositioning. The four separately acquired stations were merged, creating seamless coronal whole-body T1-, T2- and diffusion-weighted images. Anatomical alignment, image quality at the boundaries of adjacent stations, and overall image quality of all stations were qualitatively assessed. The average time (±SD) taken to change the surface coil from one station to the next station was 53.8 (±7.1) s. The average total extra examination time ± SD was 2 min 41.4 s (±15.3 s). Anatomical alignment, image quality at the boundaries of adjacent stations, and overall image quality of all stations of T1-, T2- and diffusion-weighted whole-body MRI were overall graded as ''good'' to ''excellent''. This study shows that a time-efficient and high-quality whole-body MRI examination can easily be performed by using a non-integrated sliding surface coil approach. (orig.)

  2. Very low-dose adult whole-body tumor imaging with F-18 FDG PET/CT

    Science.gov (United States)

    Krol, Andrzej; Naveed, Muhammad; McGrath, Mary; Lisi, Michele; Lavalley, Cathy; Feiglin, David

    2015-03-01

    The aim of this study was to evaluate if effective radiation dose due to PET component in adult whole-body tumor imaging with time-of-flight F-18 FDG PET/CT could be significantly reduced. We retrospectively analyzed data for 10 patients with the body mass index ranging from 25 to 50. We simulated F-18 FDG dose reduction to 25% of the ACR recommended dose via reconstruction of simulated shorter acquisition time per bed position scans from the acquired list data. F-18 FDG whole-body scans were reconstructed using time-of-flight OSEM algorithm and advanced system modeling. Two groups of images were obtained: group A with a standard dose of F-18 FDG and standard reconstruction parameters and group B with simulated 25% dose and modified reconstruction parameters, respectively. Three nuclear medicine physicians blinded to the simulated activity independently reviewed the images and compared diagnostic quality of images. Based on the input from the physicians, we selected optimal modified reconstruction parameters for group B. In so obtained images, all the lesions observed in the group A were visible in the group B. The tumor SUV values were different in the group A, as compared to group B, respectively. However, no significant differences were reported in the final interpretation of the images from A and B groups. In conclusion, for a small number of patients, we have demonstrated that F-18 FDG dose reduction to 25% of the ACR recommended dose, accompanied by appropriate modification of the reconstruction parameters provided adequate diagnostic quality of PET images acquired on time-of-flight PET/CT.

  3. Simultaneous maximal exercise radionuclide angiography and thallium stress perfusion imaging

    International Nuclear Information System (INIS)

    Narahara, K.A.; Mena, I.; Maublant, J.C.; Brizendine, M.; Criley, J.M.

    1984-01-01

    Gold-195m is a new ultra-short-lived radionuclide that can be used for cardiac studies. Accurate, reproducible ejection fraction and ventricular wall motion studies can be obtained from first-transit angiography using commercially available imaging and image-processing equipment. The short half-life of gold-195m (30.5 seconds) makes simultaneous dual isotope imaging possible and substantially reduces the radiation exposure from the isotope angiography. The feasibility and possible benefits of performing dual radionuclide studies were evaluated during a single exercise stress test in 24 subjects with known coronary artery disease (CAD) and in 20 normal volunteers. High-quality first-transit angiograms were obtained in all subjects. An 83% sensitivity and 95% specificity for detecting CAD with thallium-201 imaging was noted in this investigation, suggesting that its diagnostic accuracy was not altered by simultaneous dual isotone imaging. When segmental left ventricular (LV) wall motion was compared with thallium-201 perfusion imaging, divergent results were noted in 15 of 44 subjects. An analysis of the ejection fraction (EF) results at rest and stress provided additional information that could be useful in assessing the clinical significance of such differences in segmental wall motion and perfusion. Simultaneous dual isotope imaging appears to be appropriate for situations in which both LV perfusion and function require evaluation. The use of gold-195m allows such information to be obtained from a single exercise test and can thereby reduce the cost and time required for noninvasive evaluations of patients for CAD

  4. Chronic exposure to aluminum, nickel, thallium and uranium and their relationship with essential elements in human whole blood and blood serum.

    Science.gov (United States)

    Zeneli, Lulzim; Sekovanić, Ankica; Daci, Nexhat

    2015-01-01

    This study aimed to evaluate the influence of exposure to aluminum, nickel, thallium and uranium on the metabolism of essential elements in humans, as well as the relationship between uranium, thallium, nickel, and aluminum and essential elements (Ca, Mg, Zn, Se, Mn, Co, Cr, and Mo) in the whole blood and blood serum of healthy men who were occupationally exposed. This study included 97 healthy men, 31-64 years age, including 70 workers in a thermo power plant and 27 control subjects. The results showed that chronic, moderate exposure of trace elements (Al, Ni, Tl, and U) lead to decreased serum chromium (SCr) and blood molybdenum levels (BMo), whereas by the results achieved in terms of correlations between non-essential and essential elements, non-essential elements such as uranium, thallium, nickel, and aluminum, despite their concentration within the reference values, are strongly competitive with essential elements in biochemical processes.

  5. Thallium-201 myocardial imaging during coronary vasodilation induced by oral dipyridamole

    International Nuclear Information System (INIS)

    Gould, K.L.; Sorenson, S.G.; Albro, P.; Caldwell, J.H.; Chaudhuri, T.; Hamilton, G.W.

    1986-01-01

    Myocardial perfusion imaging of 201 TI injected during maximum exercise has been an important diagnostic tool for coronary artery disease. Pharmacologic coronary vasodilation by i.v. infusion of dipyridamole may be used in lieu of exercise stress for purposes of diagnostic perfusion imaging. However, i.v. dipyridamole is not currently available from commercial sources for widespread routine use. Accordingly, this study was carried out in order to determine whether high dose, oral dipyridamole would be useful as a coronary vasodilator for purposes of diagnostic perfusion imaging. Fifty-eight patients undergoing diagnostic coronary arteriography also had myocardial perfusion imaging with 201TI under conditions of rest, maximum exercise stress, and high dose oral dipyridamole. Of those patients who had a defect on exercise thallium images, 75% also had a perfusion defect on thallium images after high dose oral dipyridamole. These results indicate that oral dipyridamole causes sufficient coronary arteriolar vasodilation and increase of coronary flow in nonstenotic arteries to identify perfusion defects comparable to those seen on maximum exercise stress in at least 75% of cases. In 25% of patients with exercise defects, no perfusion defect was seen after oral dipyridamole. Thus, oral dipyridamole is a potent coronary vasodilator, comparable to exercise stress in most cases, but in a minority of patients may not be comparable to exercise stress

  6. Whole Body Computed Tomography with Advanced Imaging Techniques: A Research Tool for Measuring Body Composition in Dogs

    Directory of Open Access Journals (Sweden)

    Dharma Purushothaman

    2013-01-01

    Full Text Available The use of computed tomography (CT to evaluate obesity in canines is limited. Traditional CT image analysis is cumbersome and uses prediction equations that require manual calculations. In order to overcome this, our study investigated the use of advanced image analysis software programs to determine body composition in dogs with an application to canine obesity research. Beagles and greyhounds were chosen for their differences in morphology and propensity to obesity. Whole body CT scans with regular intervals were performed on six beagles and six greyhounds that were subjected to a 28-day weight-gain protocol. The CT images obtained at days 0 and 28 were analyzed using software programs OsiriX, ImageJ, and AutoCAT. The CT scanning technique was able to differentiate bone, lean, and fat tissue in dogs and proved sensitive enough to detect increases in both lean and fat during weight gain over a short period. A significant difference in lean : fat ratio was observed between the two breeds on both days 0 and 28 (P<0.01. Therefore, CT and advanced image analysis proved useful in the current study for the estimation of body composition in dogs and has the potential to be used in canine obesity research.

  7. Whole-Body CT Screening--Should I or Shouldn't I Get One?

    Science.gov (United States)

    ... Procedures Medical Imaging Medical X-ray Imaging Whole-Body CT Screening--Should I or shouldn't I ... What are the risks and benefits of whole-body CT screening? Many people believe incorrectly that a ...

  8. Assessment of myocardial viability by dynamic tomographic iodine 123 iodophenylpentadecanoic acid imaging: comparison with rest-redistribution thallium 201 imaging.

    Science.gov (United States)

    Iskandrian, A S; Powers, J; Cave, V; Wasserleben, V; Cassell, D; Heo, J

    1995-01-01

    This study examined the ability of dynamic 123I-labeled iodophenylpentadecanoic acid (IPPA) imaging to detect myocardial viability in patients with left ventricular (LV) dysfunction caused by coronary artery disease. Serial 180-degree single-photon emission computed tomographic (SPECT) images (five sets, 8 minutes each) were obtained starting 4 minutes after injection of 2 to 6 mCi 123I at rest in 21 patients with LV dysfunction (ejection fraction [EF] 34% +/- 11%). The segmental uptake was compared with that of rest-redistribution 201Tl images (20 segments/study). The number of perfusion defects (reversible and fixed) was similar by IPPA and thallium (11 +/- 5 vs 10 +/- 5 segments/patient; difference not significant). There was agreement between IPPA and thallium for presence or absence (kappa = 0.78 +/- 0.03) and nature (reversible, mild fixed, or severe fixed) of perfusion defects (kappa = 0.54 +/- 0.04). However, there were more reversible IPPA defects than reversible thallium defects (7 +/- 4 vs 3 +/- 4 segments/patient; p = 0.001). In 14 patients the EF (by gated pool imaging) improved after coronary revascularization from 33% +/- 11% to 39% +/- 12% (p = 0.002). The number of reversible IPPA defects was greater in the seven patients who had improvement in EF than in the patients without such improvement (10 +/- 4 vs 5 +/- 4 segments/patient; p = 0.075). 123I-labeled IPPA SPECT imaging is a promising new technique for assessment of viability. Reversible defects predict recovery of LV dysfunction after coronary revascularization.

  9. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    International Nuclear Information System (INIS)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto

    1997-01-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  10. Imaging technique of whole-body scintigram in the event of breakdown of the photomultiplier tube

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Syoichi; Tonami, Syuichi; Yasui, Masakazu; Sugishita, Kouki; Nakamura, Mamoru; Kuranishi, Makoto [Toyama Medical and Pharmaceutical Univ. (Japan). Hospital

    1997-10-01

    When the PMT and preamplifier are out of order, it is impossible to make a correct diagnosis because of defects on the scintigram. However, repair of the equipment may take a long time. In order to perform emergent whole-body scintigrams in the event of such breakdowns, we have developed a new approach named the lead-shield method. The major principles of this method involve placing a lead shield on the gamma camera such that it corresponds to the area of the abnormal PMT and making use of the normal area of the detector. The lead shield, 2 mm thick and 1.5 times as wide as the defect on a planar image, was situated perpendicular to the scan plane of the whole-body scintigram. The results showed that whole-body scintigrams obtained by the lead-shield method had the same quality as those obtained by the conventional method, and the spatial resolution and uniformity showed nearly no change despite some disadvantages such as lower sensitivity and shorter scan length. The lead-shield method can be a useful tool for the performance of whole-body scintigrams in cases of emergency when the PMT and preamplifier are out of order. (author)

  11. Prognostic importance of silent myocardial ischemia detected by intravenous dipyridamole thallium myocardial imaging in asymptomatic patients with coronary artery disease

    International Nuclear Information System (INIS)

    Younis, L.T.; Byers, S.; Shaw, L.; Barth, G.; Goodgold, H.; Chaitman, B.R.

    1989-01-01

    One hundred seven asymptomatic patients who underwent intravenous dipyridamole thallium imaging were evaluated to determine prognostic indicators of subsequent cardiac events over an average follow-up period of 14 +/- 10 months. Univariate analysis of 18 clinical, scintigraphic and angiographic variables revealed that a reversible thallium defect, a combined fixed and reversible thallium defect, number of segmental thallium defects and extent of coronary artery disease were significant predictors of subsequent cardiac events. Of the 13 patients who died or had a nonfatal infarction, 12 had a reversible thallium defect. Stepwise logistic regression analysis selected a reversible thallium defect as the only significant predictor of cardiac events. When death or myocardial infarction was the outcome variable, a combined fixed and reversible thallium defect was the only predictor of outcome. In patients without previous myocardial infarction, the cardiac event rate was significantly greater in those with an abnormal versus normal thallium scan (55% versus 12%, p less than 0.001). Thus, intravenous dipyridamole thallium scintigraphy is a useful noninvasive test to risk stratify asymptomatic patients with coronary artery disease. A reversible thallium defect most likely indicates silent myocardial ischemia in a sizable fraction of patients in this clinical subset and is associated with an unfavorable prognosis

  12. Dipyridamole thallium imaging may not be a reliable screening test for coronary artery disease in patients undergoing vascular surgery

    International Nuclear Information System (INIS)

    Marwick, T.H.; Underwood, D.A.

    1990-01-01

    Dipyridamole thallium imaging has been proposed for cardiac risk stratification in patients undergoing peripheral vascular surgery. The purpose of this study was to define the benefit of this investigation in routine preoperative evaluation of these patients. The outcome of 86 patients undergoing vascular surgery procedures was examined in light of preoperative clinical assessment and dipyridamole SPECT thallium imaging (DST). Fifty-one patients (59%) were considered at high risk on clinical grounds, and 22 patients (26%) had perfusion defects. Ten patients suffered a perioperative coronary event, including unstable angina, myocardial infarction, or cardiac death. Seven of the patients with such events were among the 51 clinically high-risk subjects (14%). Three perioperative events occurred in the group of 19 patients with positive DST images who underwent surgery (16%), but the DST test failed to identify 7 patients who suffered coronary events. The frequency of abnormal thallium imaging was similar to the prevalence of angiographically significant coronary disease reported previously at this center, but considerably less than the rate of abnormal thallium imaging in past studies of vascular surgery patients. The application of the test to a low to moderate risk population is probably responsible for its lower predictive accuracy for coronary events. DST is not an ideal routine noninvasive technique for risk stratification in patients undergoing vascular surgery

  13. Peritoneal fluid causing inferior attenuation on SPECT thallium-201 myocardial imaging in women

    International Nuclear Information System (INIS)

    Rab, S.T.; Alazraki, N.P.; Guertler-Krawczynska, E.

    1988-01-01

    On SPECT thallium images, myocardial left ventricular (LV) anterior wall attenuation due to breast tissue is common in women. In contrast, in men, inferior wall counts are normally decreased compared to anterior counts. The purpose of this report is to describe cases of inferior wall attenuation of counts in women caused by peritoneal fluid, not myocardial disease. Twelve consecutive SPECT thallium myocardial studies performed in women on peritoneal dialysis, being evaluated for kidney transplant, were included in this study. For all studies, 3.5 mCi 201Tl were injected intravenously. Thirty-two images were acquired over 180 degrees (45 degrees RAO progressing to 45 degrees LPO) at 40 sec per stop. SPECT images were reviewed in short axis, horizontal long and vertical long axes. Data were also displayed in bullseye format with quantitative comparison to gender-matched normal files. Ten of 12 female patients studied had inferior wall defects on images, confirmed by bullseye display. All patients had approximately 2 liters of peritoneal fluid. Review of planar rotational views showed diaphragm elevation and fluid margin attenuations affecting left ventricular inferior wall. Thus, peritoneal fluid is a cause of inferior attenuation on 201Tl cardiac imaging

  14. Comparison of atlas-based techniques for whole-body bone segmentation

    DEFF Research Database (Denmark)

    Arabi, Hossein; Zaidi, Habib

    2017-01-01

    out in terms of estimating bone extraction accuracy from whole-body MRI using standard metrics, such as Dice similarity (DSC) and relative volume difference (RVD) considering bony structures obtained from intensity thresholding of the reference CT images as the ground truth. Considering the Dice....../MRI. To this end, a variety of atlas-based segmentation strategies commonly used in medical image segmentation and pseudo-CT generation were implemented and evaluated in terms of whole-body bone segmentation accuracy. Bone segmentation was performed on 23 whole-body CT/MR image pairs via leave-one-out cross...... validation procedure. The evaluated segmentation techniques include: (i) intensity averaging (IA), (ii) majority voting (MV), (iii) global and (iv) local (voxel-wise) weighting atlas fusion frameworks implemented utilizing normalized mutual information (NMI), normalized cross-correlation (NCC) and mean...

  15. Assessment of the significance of coronary collateral vessel by using thallium-201 myocardial imaging

    International Nuclear Information System (INIS)

    Kanoh, Yasushi; Shiotani, Hideyuki; Fukuzaki, Hisashi; Maeda, Kazumi.

    1988-01-01

    For functional assessment of coronary collateral vessels, twenty-three patients with effort angina pectoris who had total coronary obstruction were studied. The patients were divided depending on the degree of development of collateral vessels into two groups, i.e. good collateral group I (n = 13) and poor collateral group II (n = 10). Thallium-201 scan was performed immediately (Ex-1 image), 20 minutes (Ex-2 image) after exercise and after nitroglycerin administration (NTG image) respectively. In all images, the relative percent activity of thallium-201 in the collateral-dependent ischemic area to the normal myocardium were calculated and were compaired between two groups. Relative percent activities in group I and II were as follows : Ex-1 image ; 75.8 ± 3.5 % vs. 77.2 ± 2.9 % (NS), Ex-2 images ; 85.3 ± 4.5 % vs. 79.3 ± 3.9 % (p < 0.005), NTG image ; 97.3 ± 3.1 % vs. 96.4 ± 5.2 % (NS). From these results, it was elucidated that good collateral induced early partial redistribution in its perfusion area, suggesting that good collateral circulation may provide rapid recovery from myocardial ischemia. (author)

  16. Thallium-201 myocardial imaging during pharmacologic coronary vasodilation: comparison of oral and intravenous administration of dipyridamole

    International Nuclear Information System (INIS)

    Taillefer, R.; Lette, J.; Phaneuf, D.C.; Leveille, J.; Lemire, F.; Essiambre, R.

    1986-01-01

    Although the diagnostic utility of thallium-201 myocardial imaging after dipyridamole infusion is well established, the intravenous form of the drug is not yet commercially available in North America. Fifty patients referred for coronary angiography were prospectively studied. Within a 2 week period, each patient underwent cardiac catheterization and thallium-201 myocardial imaging after both oral and intravenous dipyridamole administration. For the oral protocol, patients were randomly assigned to treatment with either 200 or 400 mg of dipyridamole in tablet form. Coronary artery stenoses of 70% or greater were considered significant. For the 25 patients who received a 200 mg oral dose of dipyridamole, the scintigraphic study showed perfusion defects in 65% of patients with significant coronary artery disease after the oral dose and in 85% of patients after the intravenous dose. For the 25 patients who received a 400 mg oral dose, the sensitivity of the scintigram was 84% after the oral dose and 79% after the intravenous dose. Except for headache and nausea, side effects were less severe and less frequent with oral (either 200 or 400 mg) than with intravenous dipyridamole. Because of the delayed and variable absorption of dipyridamole tablets, the oral studies required a longer period of medical supervision (45 to 60 minutes), and aminophylline was empirically administered after completion of the first set of thallium-201 images. It is concluded from this study that thallium-201 myocardial imaging after coronary vasodilation with a 400 mg oral dose of dipyridamole is a safe, widely available and reliable alternative for the evaluation of coronary artery disease in patients unable to achieve an adequate exercise level on stress testing

  17. Segmentation of rodent whole-body dynamic PET images: an unsupervised method based on voxel dynamics

    International Nuclear Information System (INIS)

    Maroy, R.; Boisgard, R.; Comtat, C.; Dolle, F.; Trebossen, R.; Tavitian, B.; Frouin, V.; Cathier, P.; Duchesnay, E.; D; Nielsen, P.E.

    2008-01-01

    Positron emission tomography (PET) is a useful tool for pharmacokinetics studies in rodents during the preclinical phase of drug and tracer development. However, rodent organs are small as compared to the scanner's intrinsic resolution and are affected by physiological movements. We present a new method for the segmentation of rodent whole-body PET images that takes these two difficulties into account by estimating the pharmacokinetics far from organ borders. The segmentation method proved efficient on whole-body numerical rat phantom simulations, including 3-14 organs, together with physiological movements (heart beating, breathing, and bladder filling). The method was resistant to spillover and physiological movements, while other methods failed to obtain a correct segmentation. The radioactivity concentrations calculated with this method also showed an excellent correlation with the manual delineation of organs in a large set of preclinical images. In addition, it was faster, detected more organs, and extracted organs' mean time activity curves with a better confidence on the measure than manual delineation. (authors)

  18. Two-dimensional Doppler echocardiographic correlation of dipyridamole-thallium stress testing with isometric handgrip

    International Nuclear Information System (INIS)

    Whitfield, S.; Aurigemma, G.; Pape, L.; Leppo, J.

    1991-01-01

    To determine how frequently new wall-motion abnormalities that are indicative of ischemia accompany thallium redistribution, 47 consecutive patients underwent two-dimensional, echocardiography during routine dipyridamole-thallium stress testing. A secondary aim of the study was to determine whether the addition of isometric handgrip exercises to the standard dipyridamole imaging protocol increased the frequency of wall-motion abnormalities or thallium redistribution. Echocardiograms and thallium scans were independently interpreted, and wall-motion abnormalities that appeared with dipyridamole, handgrip exercise, or both were compared with results of thallium imaging. Five of 24 patients with thallium redistribution had new wall-motion abnormalities, and the extent (number of segments) of thallium redistribution in these five patients was significantly greater than in those who did not have well-motion abnormalities (p less than 0.03). The addition of isometric handgrip exercises to the imaging protocol did not distinguish between patients with and without new wall-motion abnormalities or thallium redistribution. Thus new wall-motion abnormalities infrequently accompany thallium redistribution in routine dipyridamole stress testing in spite of the addition of handgrip exercises, but when new wall-motion abnormalities are present, they are associated with a greater area of thallium redistribution

  19. Quantitative thallium-201 myocardial imaging in assessing right ventricular pressure in patients with congenital heart defects

    International Nuclear Information System (INIS)

    Rabinovitch, M.; Fischer, K.C.; Treves, S.

    1981-01-01

    Thallium-201 myocardial scintigraphy was performed in patients with congenital heart defects to determine whether, by quantification of right ventricular isotope uptake, one could assess the degree of right ventricular hypertrophy and so predict the level of right ventricular pressure. It is shown that quantitative analysis of myocardial imaging with thallium-201 is of use clinically in patients with congenital heart defects, in assessing the severity of pulmonary stenosis or the presence of pulmonary artery hypertension. (author)

  20. Generating statements at whole-body imaging with a workflow-optimized software tool - first experiences with multireader analysis

    International Nuclear Information System (INIS)

    Mueller-Horvat, C.; Plathow, C.; Ludescher, B.; Lichy, M.P.; Claussen, C.D.; Schlemmer, H.P.; Canda, V.; Zindel, C.; Hahn, H.K.; Peitgen, H.O.; Kuhnigk, J.

    2007-01-01

    Introduction: Due to technical innovations in sectional diagram methods, whole-body imaging has increased in importance for clinical radiology, particularly for the diagnosis of systemic tumor disease. Large numbers of images have to be evaluated in increasingly shorter time periods. The aim was to create and evaluate a new software tool to assist and automate the process of diagnosing whole-body datasets. Material and Methods: Thirteen whole-body datasets were evaluated by 3 readers using the conventional system and the new software tool. The times for loading the datasets, examining 5 different regions (head, neck, thorax, abdomen and pelvis/skeletal system) and retrieving a relevant finding for demonstration were acquired. Additionally a Student T-Test was performed. For qualitative analysis the 3 readers used a scale from 0 - 4 (0 = bad, 4 = very good) to assess dataset loading convenience, lesion location assistance, and ease of use. Additionally a kappa value was calculated. Results: The average loading time was 39.7 s (± 5.5) with the conventional system and 6.5 s (± 1.4) (p 0.9). The qualitative analysis showed a significant advantage with respect to convenience (p 0.9). (orig.)

  1. Whole-Body MR Imaging Including Angiography: Predicting Recurrent Events in Diabetics.

    Science.gov (United States)

    Bertheau, Robert C; Bamberg, Fabian; Lochner, Elena; Findeisen, Hannes M; Parhofer, Klaus G; Kauczor, Hans-Ulrich; Schoenberg, Stefan O; Weckbach, Sabine; Schlett, Christopher L

    2016-05-01

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30%) developed one, 8 (13%) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75%, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63%, p = 0.001), carotid artery stenosis (11/17/63%, p = 0.005), peripheral artery stenosis (26/56/88%, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. • Patients with long-standing diabetes mellitus are at high risk for recurrent events. • Whole-body MRI predicts occurrence of recurrent events independently of clinical characteristics. • The vessel score derived from whole-body angiography is a good general risk-marker. • Whole-body MRI may also provide organ-specific risk assessment. • Current findings may indicate benefits of

  2. Thallium kinetics in rat cardiac transplant rejection

    International Nuclear Information System (INIS)

    Barak, J.H.; LaRaia, P.J.; Boucher, C.A.; Fallon, J.T.; Buckley, M.J.

    1988-01-01

    Cardiac transplant rejection is a very complex process involving both cellular and vascular injury. Recently, thallium imaging has been used to assess acute transplant rejection. It has been suggested that changes in thallium kinetics might be a sensitive indicator of transplant rejection. Accordingly, thallium kinetics were assessed in vivo in acute untreated rat heterotopic (cervical) transplant rejection. Male Lewis rats weighing 225-250 g received heterotopic heart transplants from syngeneic Lewis rats (group A; n = 13), or allogeneic Brown Norway rats (group B; n = 11). Rats were imaged serially on the 2nd and the 7th postoperative days. Serial cardiac thallium content was determined utilizing data collected every 150 sec for 2 hr. The data were fit to a monoexponential curve and the decay rate constant (/sec) derived. By day 7 all group B hearts had histological evidence of severe acute rejection, and demonstrated decreased global contraction. Group A hearts showed normal histology and contractility. However, thallium uptakes and washout of the two groups were the same. Peak thallium uptake of group B was +/- 3758 1166 counts compared with 3553 +/- 950 counts in the control group A (P = 0.6395); The 2-hr percentage of washout was 12.1 +/- 1.04 compared with 12.1 +/- 9.3 (P = 1.0000); and the decay constant was -0.00002065 +/- 0.00001799 compared with -0.00002202 +/- 0.00001508 (P = 0.8409). These data indicate that in vivo global thallium kinetics are preserved during mild-to-severe acute transplant rejection. These findings suggest that the complex cellular and extracellular processes of acute rejection limit the usefulness of thallium kinetics in the detection of acute transplant rejection

  3. MAGNETIC-RESONANCE-IMAGING USING A CLINICAL WHOLE-BODY SYSTEM - AN INTRODUCTION TO A USEFUL TECHNIQUE IN SMALL ANIMAL-EXPERIMENTS

    NARCIS (Netherlands)

    WOLF, RFE; LAM, KH; MOOYAART, EL; BLEICHRODT, RP; NIEUWENHUIS, P; SCHAKENRAAD, JM

    A clinical whole body magnetic resonance imaging (MRI) system with high resolution coils was used to obtain non-invasive images of the living rat. The results demonstrate the feasibility of the set-up and the advantages of this new imaging technique: detailed information, no extra costs,

  4. Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass

    Energy Technology Data Exchange (ETDEWEB)

    Bae, Sang Kyun; Yum, Ha Yong; Lee, Chung Han; Choi, Kyung Hyun [Kosin University College of Medicine, Pusan (Korea, Republic of)

    1994-07-15

    The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breast cancers, 10 cases (90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5 cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease (85%), Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  5. Usefulness of Thallium Scan for Differential Diagnosis of Breast Mass

    International Nuclear Information System (INIS)

    Bae, Sang Kyun; Yum, Ha Yong; Lee, Chung Han; Choi, Kyung Hyun

    1994-01-01

    The purpose of this study is to evaluate thallium scanning as a potential test in differentiating malignant from benign lesions of breast. Thirty-one female patients underwent thallium scan of the breast. After intravenous injection of 74-111 MBq(2-3 mCi)of thallium-201, anterior and lateral images were obtained. We compared thallium scans with pathological results. Of 11 patients with breast cancers, 10 cases (90.9%) were detected using thallium scan. Thallium scan obtained in one patient who had breast cancer but received several cycles of chemotherapy did not show thallium uptake. The smallest detectable cancer was 1.5 cm in diameter. In contrast, there is no thallium accumulation in breasts of 17 of 20 patients with benign disease (85%), Three cases of 13 fibrocystic disease show thallium uptake in their breast. In conclusion, thallium scan is an effective test in differentiating benign from malignant lesion.

  6. Whole-body MRI in adult inflammatory myopathies: Do we need imaging of the trunk?

    International Nuclear Information System (INIS)

    Filli, Lukas; Manoliu, Andrei; Andreisek, Gustav; Guggenberger, Roman; Maurer, Britta

    2015-01-01

    To evaluate whether imaging of the trunk could be omitted in patients with inflammatory myopathies without losing diagnostic accuracy using a restricted whole-body magnetic resonance imaging (rWB-MRI) protocol. After approval by the institutional review board, this study was performed in 63 patients (male/female, 13/50; median age, 52 years; range, 20-81 years) with new-onset myopathic symptoms (group 1, n = 41) or previously diagnosed inflammatory myopathy (group 2, n = 22). After performing whole-body MRI (WB-MRI) at 3.0 Tesla, myositis and fatty atrophy were evaluated in different muscles by two independent radiologists. The intra-class correlation coefficient (ICC) was calculated to evaluate inter-observer reliability. Acquisition time was 56:01 minutes for WB-MRI and 37:37 minutes (32.8 % shorter) for rWB-MRI. In group 1, 14 patients were diagnosed with inflammatory myopathy based on muscle biopsy. rWB-MRI and WB-MRI showed equal sensitivity (42.9 %) and specificity (100 %) for myositis, and showed equal sensitivity (71.4 %) and similar specificity (63.0 % and 48.1 %, respectively) for fatty atrophy. No myositis was found in the body trunk in any patient. Inter-observer reliability was between substantial and perfect (ICC, 0.77-1.00). rWB-MRI showed diagnostic accuracy similar to WB-MRI for inflammatory myopathy at markedly reduced overall acquisition time. (orig.)

  7. Whole-body MRI in adult inflammatory myopathies: Do we need imaging of the trunk?

    Energy Technology Data Exchange (ETDEWEB)

    Filli, Lukas; Manoliu, Andrei; Andreisek, Gustav; Guggenberger, Roman [University Hospital Zurich, University of Zurich, Institute of Diagnostic and Interventional Radiology, Zurich (Switzerland); Maurer, Britta [University Hospital Zurich, University of Zurich, Division of Rheumatology, Zurich (Switzerland)

    2015-12-15

    To evaluate whether imaging of the trunk could be omitted in patients with inflammatory myopathies without losing diagnostic accuracy using a restricted whole-body magnetic resonance imaging (rWB-MRI) protocol. After approval by the institutional review board, this study was performed in 63 patients (male/female, 13/50; median age, 52 years; range, 20-81 years) with new-onset myopathic symptoms (group 1, n = 41) or previously diagnosed inflammatory myopathy (group 2, n = 22). After performing whole-body MRI (WB-MRI) at 3.0 Tesla, myositis and fatty atrophy were evaluated in different muscles by two independent radiologists. The intra-class correlation coefficient (ICC) was calculated to evaluate inter-observer reliability. Acquisition time was 56:01 minutes for WB-MRI and 37:37 minutes (32.8 % shorter) for rWB-MRI. In group 1, 14 patients were diagnosed with inflammatory myopathy based on muscle biopsy. rWB-MRI and WB-MRI showed equal sensitivity (42.9 %) and specificity (100 %) for myositis, and showed equal sensitivity (71.4 %) and similar specificity (63.0 % and 48.1 %, respectively) for fatty atrophy. No myositis was found in the body trunk in any patient. Inter-observer reliability was between substantial and perfect (ICC, 0.77-1.00). rWB-MRI showed diagnostic accuracy similar to WB-MRI for inflammatory myopathy at markedly reduced overall acquisition time. (orig.)

  8. Diagnosis of coronary stenosis using thallium-201 myocardial emission computed tomography

    International Nuclear Information System (INIS)

    Ito, Tsunaaki; Takeda, Hiroshi; Maeda, Hisato; Nakagawa, Tsuyoshi; Yamaguchi, Nobuo; Makino, Katsutoshi; Futagami, Yasuo; Konishi, Tokuji

    1985-01-01

    Thallium-201 myocardial emission computed tomography (ECT) was described with respect to methods of correcting ECT data and reconstructing the images, qualitative and quantitative diagnosis in the detection of coronary stenosis. Although 201 Tl myocardial ECT (using circumferential profile method combined with washout method) has relatively high diagnostic sensitivity, the correction of absorption is not satisfactory yet. Inside absorption coefficient is considered uniform by regarding the human body as oval shape. However, the chest, including the heart, lungs, vertebrae and thoracic wall, has four different absorption coefficients. If absorption can be corrected accurately, it will be possible to completely assess the myocardial blood flow by measuring the regional myocardial uptake of thallium-201. (Namekawa, K.)

  9. Chest Pain with Normal Thallium-201 Myocardial Perfusion Image – Is It Really Normal?

    Science.gov (United States)

    Liu, Pang-Yen; Lin, Wen-Yu; Lin, Li-Fan; Lin, Chin-Sheng; Lin, Wei-Shiang; Cheng, Shu-Meng; Yang, Shih-Ping; Liou, Jun-Ting

    2016-01-01

    Background Thallium-201 myocardial perfusion image (MPI) is commonly used to detect coronary artery disease in patients with chest pain. Although a normal thallium-201 MPI result is generally considered to be a good prognosis and further coronary angiogram is not recommended, there are still a few patients who suffer from unexpected acute coronary events. The aim of this study was to investigate the clinical prognosis in patients with normal thallium-201 MPI. Methods From January 2006 to August 2012, a total 22,003 patients undergoing thallium-201 MPI in one tertiary center were screened. Of these, 8092 patients had normal results and were investigated retrospectively. During follow-up, 54 patients underwent coronary angiogram because of refractory typical angina pectoris or unexpected acute coronary events. These 54 patients were divided into 2 groups: group I consisted of 26 (48.1%) patients with angiography-proven significant coronary artery stenosis, and group II consisted of 28 (51.9%) patients without significant stenosis. Results Patients in group I had a higher prevalence of prior coronary stenting and electrocardiographic features of ST depression compared with patients in group II. The multivariate analysis demonstrated that both prior coronary stenting and ST depression were risk predictors of unexpected acute coronary events in the patients with normal thallium-201 MPI [odds ratio (OR), 5.93; 95% confidence interval (CI): 1.03-34.06, p = 0.05 and OR, 7.10; 95% CI: 1.28-39.51, p = 0.03,respectively]. Conclusions Although there is a low incidence of unexpected acute coronary events in patients with chest pain and normal thallium-201 MPI, physicians should be aware of the potentials risk in certain patients in this specific population. PMID:27274174

  10. Evaluation of myocardial involvement in Duchenne's progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Sotobata, Iwao; Okada, Mitsuhiro

    1985-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. A qualitative analysis was performed from five projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in the LV posterolateral or posterior wall (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle involvements or thoracic deformities assessed by transmission computed tomography. Extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. Progression of the myocardial scintigraphic abnormalities were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies over 2 to 3 years. It was concluded that thallium myocardial perfusion imaging is a useful clinical technique to assess myocardial involvement in Duchenne's progressive muscular dystrophy. (author)

  11. Pseudonormalization of transmitral flow pattern during exercise thallium-201 imaging in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Shiota, Takahiro; Sakamoto, Tsuguya; Takenaka, Katsu; Amano, Keiko; Amano, Wataru; Igarashi, Tsutomu; Otake, Takeshi; Sugimoto, Tsuneaki

    1993-01-01

    This study was undertaken to assess the usefulness of Doppler parameters and transmitral blood velocity for detecting abnormalities of left ventricular diastolic function during low-level exercise thallium-201 imaging. The study population consisted of 16 thallium perfusion defect patients with coronary artery disease (mean 61±8 years) and 21 age-matched control subjects (mean 55±5 years) without any thallium perfusion defect. Of the 16 thallium perfusion defect patients, 12 were examined by coronary arteriography, of whom single vessel coronary artery disease was seen in 2 and multivessel coronary artery disease in 10. Patients with mitral regurgitant murmurs were excluded from the study. Peak mitral blood flow velocity was measured in early diastole (E) and during atrial systole (A) and the A/E ratio was calculated. The changes in blood pressure and heart rate after low-level exercise were not significantly different between control and thallium perfusion defect groups. The A/E ratio increased slightly in control subjects from 93±14% at baseline to 100±15% during low-level exercise (p<0.05), whereas in patients with thallium perfusion defect, it decreased significantly from 119±33% at baseline to 92±23% during low-level exercise (p<0.01). Thus pseudonormalization of the A/E ratio during low-level exercise may be valuable in the evaluation of patients with severe or multivessel coronary artery disease. (author)

  12. Quantification of interstitial fluid on whole body CT: comparison with whole body autopsy.

    Science.gov (United States)

    Lo Gullo, Roberto; Mishra, Shelly; Lira, Diego A; Padole, Atul; Otrakji, Alexi; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Singh, Sarabjeet; Shepard, Jo-Anne O; Digumarthy, Subba R; Kalra, Mannudeep K; Stone, James R

    2015-12-01

    Interstitial fluid accumulation can occur in pleural, pericardial, and peritoneal spaces, and subcutaneous tissue planes. The purpose of the study was to assess if whole body CT examination in a postmortem setting could help determine the presence and severity of third space fluid accumulation in the body. Our study included 41 human cadavers (mean age 61 years, 25 males and 16 females) who had whole-body postmortem CT prior to autopsy. All bodies were maintained in the morgue in the time interval between death and autopsy. Two radiologists reviewed the whole-body CT examinations independently to grade third space fluid in the pleura, pericardium, peritoneum, and subcutaneous space using a 5-point grading system. Qualitative CT grading for third space fluid was correlated with the amount of fluid found on autopsy and the quantitative CT fluid volume, estimated using a dedicated software program (Volume, Syngo Explorer, Siemens Healthcare). Moderate and severe peripheral edema was seen in 16/41 and 7/41 cadavers respectively. It is not possible to quantify anasarca at autopsy. Correlation between imaging data for third space fluid and the quantity of fluid found during autopsy was 0.83 for pleural effusion, 0.4 for pericardial effusion and 0.9 for ascites. The degree of anasarca was significantly correlated with the severity of ascites (p < 0.0001) but not with pleural or pericardial effusion. There was strong correlation between volumetric estimation and qualitative grading for anasarca (p < 0.0001) and pleural effusion (p < 0.0001). Postmortem CT can help in accurate detection and quantification of third space fluid accumulation. The quantity of ascitic fluid on postmortem CT can predict the extent of anasarca.

  13. Persistent chest pain following oral dipyridamole for thallium 201 myocardial imaging

    International Nuclear Information System (INIS)

    Kwai, A.H.; Jacobson, A.F.; McIntyre, K.M.; Williams, W.H.; Tow, D.E.

    1990-01-01

    A patient was admitted to the hospital with acute chest pain. After acute myocardial infarction was ruled out, he underwent a stress thallium 201 scintigraphy using oral dipyridamole and developed persistent angina with sedimentation time segement elevation. This complication has not been reported previously. It is recommended that appropriate intervention be available if severe ischemia develops following administration of dipyridamole for diagnostic imaging. (orig.)

  14. Safety and diagnostic accuracy of dipyridamole-thallium imaging in the elderly

    International Nuclear Information System (INIS)

    Lam, J.Y.; Chaitman, B.R.; Glaenzer, M.; Byers, S.; Fite, J.; Shah, Y.; Goodgold, H.; Samuels, L.

    1988-01-01

    The noninvasive diagnosis of coronary artery disease in the elderly can occasionally be difficult. Intravenous dipyridamole-thallium imaging is a potentially useful diagnostic test to determine presence and severity of coronary disease; however, the safety of the procedure has not been determined in an older population. The side effect profile and frequency of severe ischemic responses after 0.56 mg/kg of intravenous dipyridamole were compared in 101 patients greater than or equal to 70 years old and 236 patients less than 70 years old. There were no side effects in 64% and 62% of patients greater than or equal to 70 and less than 70 years old, respectively (p = NS). Among the 337 patients tested, there were no complications of myocardial infarction or death. The most common cardiac side effect was chest pain, which occurred in 21 (21%) of the 101 patients aged greater than or equal to 70 years and in 64 (27%) of the 236 patients less than 70 years (p = NS). Aminophylline was required to reverse cardiac or noncardiac side effects in 15 (15%) and 36 (15%) of the patients greater than or equal to 70 and less than 70 years old, respectively (p = NS). A severe ischemic response occurred in 2% and 2.5% of patients greater than or equal to 70 and less than 70 years old, respectively (p = NS). The sensitivity of intravenous dipyridamole-thallium imaging for obstructive coronary artery disease was 86% (25 of 29) and 83% (68 of 82) in older and younger patients, respectively (p = NS); the specificity was 75% (6 of 8) and 70% (16 of 23), respectively (p = NS). Thus, intravenous dipyridamole-thallium imaging is a safe noninvasive method for assessment of older patients with obstructive coronary disease; its side effect profile and diagnostic accuracy are similar to those seen in younger patients. The technique is associated with severe ischemic responses in only a small minority of patients

  15. Chelation of thallium by combining deferasirox and desferrioxamine in rats.

    Science.gov (United States)

    Saljooghi, Amir Shokooh; Babaie, Maryam; Mendi, Fatemeh Delavar; Zahmati, Maliheh; Saljooghi, Zoheir Shokouh

    2016-01-01

    The hypothesis that two known chelators deferasirox (4-[3,5-bis(2-hydroxyphenyl)-1,2,4-triazol-1-yl]-benzoic acid) and desferrioxamine (DFO) might be more efficient as combined treatment than as monotherapies in removing thallium from the body was tested in a new acute rat model. 7-week-old male Wistar rats received chelators: deferasirox (orally), DFO (intraperitoneal; i.p.), or deferasirox + DFO as 75 or 150 mg/kg dose half an hour after a single i.p. administration of 8 mg thallium/kg body weight in the form of chloride. Serum thallium concentration, urinary thallium, and iron excretions were determined by graphite furnace atomic absorption spectrometry. Both chelators were effective only at the higher dose level, while DFO was more effective than deferasirox in enhancing urinary thallium excretion, deferasirox was more effective than DFO in enhancing urinary iron excretion. In the combined treatment group, deferasirox did not increase the DFO effect on thallium and DFO did not increase the effect of deferasirox on iron elimination. Our results support the usefulness of this animal model for preliminary in vivo testing of thallium chelators. Urinary values were more useful because of the high variability of serum results. © The Author(s) 2013.

  16. Starting up stress thallium cardiac imaging services.

    Science.gov (United States)

    Owens, R G; Neubecker, J S

    1992-01-01

    This paper presents an evaluation of alternative methods for a hospital to establish stress thallium cardiac imaging services at a group of physicians' office. Volume-cost-profit analysis, break-even analysis and capital budgeting techniques were used to determine the most feasible method from a financial perspective without sacrificing quality of services. The main focus of this evaluation centers upon three alternative methods of procuring an imaging camera: (1) purchasing a new camera, (2) purchasing used equipment, or (3) leasing a new camera. Budgeted income statements were constructed using relevant revenue and cost information for each alternative. The payback period, net present value and the internal rate of return for each method of procuring a camera was computed. In addition, the break-even point was also determined for each alternative. After the analysis was completed, it was concluded that the method of choice, without sacrificing quality of service delivery, was that of purchasing a used camera.

  17. Visualization of atrial myocardium with thallium-201: case report

    International Nuclear Information System (INIS)

    Cowley, M.J.; Coghlan, H.C.; Logic, J.R.

    1977-01-01

    An adult patient evaluated for cyanotic congenital heart disease was found to have pulmonary atresia with intact ventricular septum, hypoplastic right ventricle, and right atrial enlargement. Thallium-201 myocardial imaging before surgical correction showed thallium activity in the right atrium. Following the establishment of a conduit from the right atrium to pulmonary artery, the right-atrial thallium uptake was even more prominent

  18. Diffusion-weighted whole-body MR imaging with background body signal suppression: a feasibility study at 3.0 Tesla

    International Nuclear Information System (INIS)

    Muertz, Petra; Krautmacher, Carsten; Traeber, Frank; Schild, Hans H.; Willinek, Winfried A.; Gieseke, Juergen

    2007-01-01

    The purpose was to provide a diffusion-weighted whole-body magnetic resonance (MR) imaging sequence with background body signal suppression (DWIBS) at 3.0 Tesla. A diffusion-weighted spin-echo echo-planar imaging sequence was combined with the following methods of fat suppression: short TI inversion recovery (STIR), spectral attenuated inversion recovery (SPAIR), and spectral presaturation by inversion recovery (SPIR). Optimized sequences were implemented on a 3.0- and a 1.5-Tesla system and evaluated in three healthy volunteers and six patients with various lesions in the neck, chest, and abdomen on the basis of reconstructed maximum intensity projection images. In one patient with metastases of malignant melanoma, DWIBS was compared with 18 F-fluorodeoxyglucose positron emission tomography (FDG-PET). Good fat suppression for all regions and diagnostic image quality in all cases could be obtained at 3.0 Tesla with the STIR method. In comparison with 1.5 Tesla, DWIBS images at 3.0 Tesla were judged to provide a better lesion-to-bone tissue contrast. However, larger susceptibility-induced image distortions and signal intensity losses, stronger blurring artifacts, and more pronounced motion artifacts degraded the image quality at 3.0 Tesla. A good correlation was found between the metastases as depicted by DWIBS and those as visualized by FDG-PET. DWIBS is feasible at 3.0 Tesla with diagnostic image quality. (orig.)

  19. Identification of viable myocardium in patients with chronic coronary artery disease and left ventricular dysfunction. Comparison of thallium scintigraphy with reinjection and PET imaging with 18F-fluorodeoxyglucose

    International Nuclear Information System (INIS)

    Bonow, R.O.; Dilsizian, V.; Cuocolo, A.; Bacharach, S.L.

    1991-01-01

    In patients with chronic coronary artery disease and left ventricular dysfunction, the distinction between ventricular dysfunction arising from myocardial fibrosis and ischemic, but viable, myocardium has important clinical implications. By positron emission tomography (PET), enhanced fluorine-18-labeled fluorodeoxyglucose (FDG) uptake in myocardial segments with impaired function and reduced blood flow is evidence of myocardial viability. Reinjection of thallium-201 at rest immediately after stress-redistribution imaging may also provide evidence of myocardial viability by demonstrating thallium uptake in regions with apparently irreversible defects. To compare these two methods, we studied 16 patients with chronic coronary artery disease and left ventricular dysfunction, all of whom had irreversible defects on standard exercise-redistribution thallium single-photon emission computed tomography (SPECT) imaging. Thallium was reinjected immediately after the redistribution study, and SPECT images were reacquired. The patients also underwent PET imaging with FDG and oxygen-15-labeled water. A total of 432 myocardial segments were analyzed from comparable transaxial tomograms, of which 166 (38%) had irreversible thallium defects on redistribution images before reinjection. FDG uptake was demonstrated in 121 (73%) of these irreversible defects. Irreversible defects were then subgrouped according to the degree of thallium activity, relative to peak activity in normal regions. Irreversible defects with only mild (60-85% of peak activity) or moderate (50-59% of peak) reduction in thallium activity were considered viable on the basis of FDG uptake in 91% and 84% of these segments, respectively. In contrast, in irreversible defects with severe reduction in thallium activity (less than 50% of peak), FDG uptake was present in 51% of segments

  20. Quantitation of postexercise lung thallium-201 uptake during single photon emission computed tomography

    International Nuclear Information System (INIS)

    Kahn, J.K.; Carry, M.M.; McGhie, I.; Pippin, J.J.; Akers, M.S.; Corbett, J.R.

    1989-01-01

    To test the hypothesis that analysis of lung thallium uptake measured during single photon emission computed tomography (SPECT) yields supplementary clinical information as reported for planar imaging, quantitative analysis of lung thallium uptake following maximal exercise was performed in 40 clinically normal subjects (Group 1) and 15 angiographically normal subjects (Group 2). Lung thallium uptake was measured from anterior projection images using a ratio of heart-to-lung activities. Seventy subjects with coronary artery disease (CAD) (Group 3) determined by angiography (greater than or equal to 70% luminal stenosis) underwent thallium perfusion SPECT. Thirty-nine percent of these subjects had multivessel and 61% had single vessel CAD. Lung thallium uptake was elevated in 47 of 70 (67%) Group 3 subjects. Group 3 subjects with elevated lung thallium uptake did not differ from Group 3 subjects with normal lung thallium uptake with respect to extent or distribution of coronary artery disease, left ventricular function, or severity of myocardial ischemia as determined by exercise and redistribution thallium SPECT. Thus, the measurement of thallium lung uptake from anterior projection images obtained during SPECT frequently identifies patients with CAD, but it may not provide supplementary information regarding the extent of myocardial ischemia or ventricular dysfunction

  1. A Registration Method Based on Contour Point Cloud for 3D Whole-Body PET and CT Images

    Directory of Open Access Journals (Sweden)

    Zhiying Song

    2017-01-01

    Full Text Available The PET and CT fusion image, combining the anatomical and functional information, has important clinical meaning. An effective registration of PET and CT images is the basis of image fusion. This paper presents a multithread registration method based on contour point cloud for 3D whole-body PET and CT images. Firstly, a geometric feature-based segmentation (GFS method and a dynamic threshold denoising (DTD method are creatively proposed to preprocess CT and PET images, respectively. Next, a new automated trunk slices extraction method is presented for extracting feature point clouds. Finally, the multithread Iterative Closet Point is adopted to drive an affine transform. We compare our method with a multiresolution registration method based on Mattes Mutual Information on 13 pairs (246~286 slices per pair of 3D whole-body PET and CT data. Experimental results demonstrate the registration effectiveness of our method with lower negative normalization correlation (NC = −0.933 on feature images and less Euclidean distance error (ED = 2.826 on landmark points, outperforming the source data (NC = −0.496, ED = 25.847 and the compared method (NC = −0.614, ED = 16.085. Moreover, our method is about ten times faster than the compared one.

  2. Comparison of drug distribution images from whole-body thin tissue sections obtained using desorption electrospray ionization tandem mass spectrometry and autoradiography.

    Science.gov (United States)

    Kertesz, Vilmos; Van Berkel, Gary J; Vavrek, Marissa; Koeplinger, Kenneth A; Schneider, Bradley B; Covey, Thomas R

    2008-07-01

    Desorption electrospray ionization tandem mass spectrometry (DESI-MS/MS) and whole-body autoradiography (WBA) were used for chemical imaging of whole-body thin tissue sections of mice intravenously dosed with propranolol (7.5 mg/kg). DESI-MS/MS imaging utilized selected reaction monitoring detection performed on an AB/MDS SCIEX 4000 QTRAP mass spectrometer equipped with a prototype extended length particle discriminator interface. Propranolol images of the tissue sections using DESI-MS/MS were obtained at surface scan rates of 0.1, 0.5, 2, and 7 mm/s. Although signal decreased with increasing scan rate, useful whole-body images for propranolol were obtained from the tissues even at 7 mm/s, which required just 79 min of analysis time. Attempts to detect and image the distribution of the known propranolol metabolites were unsuccessful. Regions of the tissue sections showing the most radioactivity from WBA sections were excised and analyzed by high-performance liquid chromatography (HPLC) with radiochemical detection to determine relative levels of propranolol and metabolites present. Comparison of the DESI-MS/MS signal for propranolol and the radioactivity attributed to propranolol from WBA sections indicated nominal agreement between the two techniques for the amount of propranolol in the brain, lung, and liver. Data from the kidney showed an unexplained disparity between the two techniques. The results of this study show the feasibility of using DESI-MS/MS to obtain useful chemical images of a drug in whole-body thin tissue sections following drug administration at a pharmacologically relevant level. Further optimization to improve sensitivity and enable detection of the drug metabolites will be among the requirements necessary to move DESI-MS/MS chemical imaging forward as a practical tool in drug discovery.

  3. Thallium-201 myocardial imaging in acute-myocardial infarction

    International Nuclear Information System (INIS)

    Wackers, F.J.Th.; Lie, K.I.; Sokole, E.B.; Wellens, H.J.J.; Samson, G.; Schoot, J.B. van der

    1980-01-01

    Thallium-201 scintigraphy has proven to be an early and highly sensitive technique to detect myocardial perfusion abnormalities in patients with acute myocardial infarction. During the early phase of acute myocardial infarction, patients may be hemodynamically and electrically unstable. Therefore, scintigraphy is performed preferably at the bed side in the Coronary Care Unit using a mobile gamma camera. Additionally, in order to shorten imaging time in these often critically ill patients, the authors recommend injecting no less than 2 mCi of 201 Tl. Using this dosage, the imaging time per view will be approximately five minutes. Routinely, three views are taken: the first view is a supine 45 0 left-anterior-oblique view, followed by a supine anterior view and finally a left-lateral view, the latter with the patient turned on the right side. (Auth.)

  4. Whole-body imaging of whole-organ, subresolution, basic functional unit (BFU) perfusion characteristics

    Science.gov (United States)

    Dong, Yue; Ritman, Erik L.

    2008-08-01

    A BFU is an organ's smallest assembly of diverse cells that functions like the organ, such as the liver's hepatic lobules. There are approximately 107 BFUs in a human organ. These 100-200 μm structures are perfused by capillaries fed by a terminal arteriole (15μm diameter). BFU sizes, function and number per organ vary with disease, either by loss of BFUs and/or their decrease in function. The BFU is the upper limit of a spherical assembly of cells, immersed in a suitably nutrient medium, which can survive without its own blood supply. However, each BFU has its own blood supply to support the extra energy and/or solutes needed for providing its physiological function (e.g., contraction or secretion). A BFU function is best evaluated by its micro-perfusion, which can be readily evaluated with whole-body CT. Resolution of individual BFUs within in-situ organs, using clinical imaging devices, would require high radiation doses and/or the intolerably long scan-durations needed for suitable signal-to-noise image-data. However, it is possible to obtain a statistical description of the BFU number, size and function from wholebody CT by way of a model. In this study we demonstrate this capability by using the distribution of myocardial terminal arteriolar perfusion territories by way of a nested, multiple, regions-of-interest analysis of the heart wall imaged during transient opacification of its blood supply.

  5. Whole-body and Whole-Organ Clearing and Imaging Techniques with Single-Cell Resolution: Toward Organism-Level Systems Biology in Mammals.

    Science.gov (United States)

    Susaki, Etsuo A; Ueda, Hiroki R

    2016-01-21

    Organism-level systems biology aims to identify, analyze, control and design cellular circuits in organisms. Many experimental and computational approaches have been developed over the years to allow us to conduct these studies. Some of the most powerful methods are based on using optical imaging in combination with fluorescent labeling, and for those one of the long-standing stumbling blocks has been tissue opacity. Recently, the solutions to this problem have started to emerge based on whole-body and whole-organ clearing techniques that employ innovative tissue-clearing chemistry. Here, we review these advancements and discuss how combining new clearing techniques with high-performing fluorescent proteins or small molecule tags, rapid volume imaging and efficient image informatics is resulting in comprehensive and quantitative organ-wide, single-cell resolution experimental data. These technologies are starting to yield information on connectivity and dynamics in cellular circuits at unprecedented resolution, and bring us closer to system-level understanding of physiology and diseases of complex mammalian systems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Excess of Radiation Burden for Young Testicular Cancer Patients using Automatic Exposure Control and Contrast Agent on Whole-body Computed Tomography Imaging.

    Science.gov (United States)

    Niiniviita, Hannele; Kulmala, Jarmo; Pölönen, Tuukka; Määttänen, Heli; Järvinen, Hannu; Salminen, Eeva

    2017-06-01

    The aim of the study was to assess patient dose from whole-body computed tomography (CT) in association with patient size, automatic exposure control (AEC) and intravenous (IV) contrast agent. Sixty-five testicular cancer patients (mean age 28 years) underwent altogether 279 whole-body CT scans from April 2000 to April 2011. The mean number of repeated examinations was 4.3. The GE LightSpeed 16 equipped with AEC and the Siemens Plus 4 CT scanners were used for imaging. Whole-body scans were performed with (216) and without (63) IV contrast. The ImPACT software was used to determine the effective and organ doses. Patient doses were independent (p < 0.41) of patient size when the Plus 4 device (mean 7.4 mSv, SD 1.7 mSv) was used, but with the LightSpeed 16 AEC device, the dose (mean 14 mSv, SD 4.6 mSv) increased significantly (p < 0.001) with waist cirfumference. Imaging with the IV contrast agent caused significantly higher (13% Plus 4, 35% LightSpeed 16) exposure than non-contrast imaging (p < 0.001). Great caution on the use of IV contrast agent and careful set-up of the AEC modulation parameters is recommended to avoid excessive radiation exposure on the whole-body CT imaging of young patients.

  7. Diffusion-weighted imaging as part of hybrid PET/MRI protocols for whole-body cancer staging: Does it benefit lesion detection?

    Energy Technology Data Exchange (ETDEWEB)

    Buchbender, Christian, E-mail: christian.buchbender@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Hartung-Knemeyer, Verena, E-mail: verena.hartung@uk-essen.de [Univ Duisburg-Essen, Medical Faculty, Department of Nuclear Medicine, Hufelandstr. 55, D-45147 Essen (Germany); Beiderwellen, Karsten, E-mail: karsten.beiderwellen@uk-essen.de [Univ Duisburg-Essen, Medical Faculty, Department of Diagnostic and Interventional Radiology and Neuroradiology, Hufelandstr. 55, D-45147 Essen (Germany); Heusch, Philipp, E-mail: philipp.heusch@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Kühl, Hilmar, E-mail: hilmar.kuehl@uni-due.de [Univ Duisburg-Essen, Medical Faculty, Department of Diagnostic and Interventional Radiology and Neuroradiology, Hufelandstr. 55, D-45147 Essen (Germany); Lauenstein, Thomas C., E-mail: thomas.lauenstein@uk-essen.de [Univ Duisburg-Essen, Medical Faculty, Department of Diagnostic and Interventional Radiology and Neuroradiology, Hufelandstr. 55, D-45147 Essen (Germany); Forsting, Michael, E-mail: michael.forsting@uk-essen.de [Univ Duisburg-Essen, Medical Faculty, Department of Diagnostic and Interventional Radiology and Neuroradiology, Hufelandstr. 55, D-45147 Essen (Germany); Antoch, Gerald, E-mail: antoch@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany); Heusner, Till A., E-mail: heusner@med.uni-duesseldorf.de [Univ Dusseldorf, Medical Faculty, Department of Diagnostic and Interventional Radiology, Moorenstr. 5, D-40225 Dusseldorf (Germany)

    2013-05-15

    Purpose: Positron emission tomography/magnetic resonance imaging (PET/MRI) requires efficient scan protocols for whole-body cancer staging. The aim of this study was to evaluate if the application of diffusion-weighted MR imaging (DWI) results in a diagnostic benefit for lesion detection in oncologic patients if added to a whole-body [18F]-fluorodesoxyglucose ([18F]-FDG) PET/MRI protocol. Methods: 25 consecutive oncologic patients (16 men, 9 women; age 57 ± 12 years) prospectively underwent whole-body [18F]-FDG-PET/MRI including DWI on a hybrid PET/MRI scanner. A team of two readers assessed [18F]-FDG PET/MRI without DWI for primary tumors and metastases. In a second session, now considering DWI, readers reassessed [18F]-FDG PET/MRI accordingly. Additionally, the lesion-to-background contrast on [18F]-FDG PET and DWI was rated qualitatively (0, invisible; 1, low; 2, intermediate; 3, high). Wilcoxon's signed-rank test was performed to test for differences in the lesion-to-background contrast. Results: 49 lesions were detected in 16 patients (5 primaries, 44 metastases). All 49 lesions were concordantly detected by [18F]-FDG PET/MRI alone and [18F]-FDG PET/MRI with DWI. The lesion-to-background contrast on DWI compared to [18F]-FDG PET was rated lower in 22 (44.9%) of 49 detected lesions resulting in a significantly higher lesion-to-background contrast on [18F]-FDG PET compared to DWI (P = 0.001). Conclusions: DWI as part of whole-body [18F]-FDG PET/MRI does not benefit lesion detection. Given the necessity to optimize imaging protocols with regard to patient comfort and efficacy, DWI has to be questioned as a standard tool for whole-body staging in oncologic PET/MRI.

  8. Whole body imaging system mechanism

    International Nuclear Information System (INIS)

    Carman, R.W.; Doherty, E.J.

    1980-01-01

    A radioisotope scanning apparatus for use in nuclear medicine is described in detail. The apparatus enables the quantification and spatial location of the radioactivity in a body section of a patient to be determined with high sensitivity. It consists of an array of highly focussed collimators arranged such that adjacent collimators move in the same circumferential but opposite radial directions. The explicit movements of the gantry are described in detail and may be controlled by a general purpose computer. The use of highly focussed collimators allows both a reasonable solid angle of acceptance and also high target to background images; additionally, dual radionuclide pharmaceutical studies can be performed simultaneously. It is claimed that the high sensitivity of the system permits the early diagnosis of pathological changes and the images obtained show accurately the location and shape of physiological abnormalities. (U.K.)

  9. Whole Body Counters (rev.)

    Energy Technology Data Exchange (ETDEWEB)

    Woodburn, John H. [Walter Johnson High School, Rockville, MD; Lengemann, Frederick W. [Cornell University

    1967-01-01

    Whole body counters are radiation detecting and measuring instruments that provide information about the human body. This booklet describes different whole body counters, scientific principles that are applied to their design, and ways they are used.

  10. Characterization of intact subcellular bodies in whole bacteria by cryo-electron tomography and spectroscopic imaging.

    Science.gov (United States)

    Comolli, L R; Kundmann, M; Downing, K H

    2006-07-01

    We illustrate the combined use of cryo-electron tomography and spectroscopic difference imaging in the study of subcellular structure and subcellular bodies in whole bacteria. We limited our goal and focus to bodies with a distinct elemental composition that was in a sufficiently high concentration to provide the necessary signal-to-noise level at the relatively large sample thicknesses of the intact cell. This combination proved very powerful, as demonstrated by the identification of a phosphorus-rich body in Caulobacter crescentus. We also confirmed the presence of a body rich in carbon, demonstrated that these two types of bodies are readily recognized and distinguished from each other, and provided, for the first time to our knowledge, structural information about them in their intact state. In addition, we also showed the presence of a similar type of phosphorus-rich body in Deinococcus grandis, a member of a completely unrelated bacteria genus. Cryo-electron microscopy and tomography allowed the study of the biogenesis and morphology of these bodies at resolutions better than 10 nm, whereas spectroscopic difference imaging provided a direct identification of their chemical composition.

  11. Serial assessment of myocardial thallium perfusion and fatty acid utilization in spontaneously hypertensive rats

    International Nuclear Information System (INIS)

    Sago, Masayoshi; Nishimura, Tsunehiko

    1989-01-01

    To evaluate the advantage of free fatty acid imaging on the detection of hypertrophied myocardium, we compared sequentially myocardial thallium and BMIPP (15-(p-iodophenyl)-3-(R,S)-methyl pentadecanoic acid) distribution in spontaneously hypertensive rat (SHR) using dual tracer autoradiography and in vivo pin-hole imaging. Autoradiography and pin-hole imaging showed uniform myocardial distribution of BMIPP and thallium within less than 27 weeks age SHR. In 40 weeks age SHR, thallium myocardial distribution showed uniform, however, BMIPP had focal decrease. Quantitative analysis of pin-hole images showed that myocardial BMIPP and thallium uptake ratio decreased according to the ages of SHR. Our data suggest that hypertension is associated with uniform myocardial perfusion and focal alternation in the substrate used for the performance of myocardial work. Based on the above autoradiographic and in vivo pin-hole imagings, I-123 BMIPP imaging may have a potential for early detection on hypertrophic myocardium compared to thallium perfusion in clinically hypertensive patients. (author)

  12. Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging

    International Nuclear Information System (INIS)

    Hu, Zhengyi; Yuan, Xunhua; Pollmann, Steven I; Nikolov, Hristo N; Holdsworth, David W; Welch, Ian

    2015-01-01

    Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as  ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice. (paper)

  13. Quantification of mouse in vivo whole-body vibration amplitude from motion-blur using x-ray imaging

    Science.gov (United States)

    Hu, Zhengyi; Welch, Ian; Yuan, Xunhua; Pollmann, Steven I.; Nikolov, Hristo N.; Holdsworth, David W.

    2015-08-01

    Musculoskeletal effects of whole-body vibration on animals and humans have become an intensely studied topic recently, due to the potential of applying this method as a non-pharmacological therapy for strengthening bones. It is relatively easy to quantify the transmission of whole-body mechanical vibration through the human skeletal system using accelerometers. However, this is not the case for small-animal pre-clinical studies because currently available accelerometers have a large mass, relative to the mass of the animals, which causes the accelerometers themselves to affect the way vibration is transmitted. Additionally, live animals do not typically remain motionless for long periods, unless they are anesthetized, and they are required to maintain a static standing posture during these studies. These challenges provide the motivation for the development of a method to quantify vibrational transmission in small animals. We present a novel imaging technique to quantify whole-body vibration transmission in small animals using 280 μm diameter tungsten carbide beads implanted into the hind limbs of mice. Employing time-exposure digital x-ray imaging, vibrational amplitude is quantified based on the blurring of the implanted beads caused by the vibrational motion. Our in vivo results have shown this technique is capable of measuring vibration amplitudes as small as 0.1 mm, with precision as small as  ±10 μm, allowing us to distinguish differences in the transmitted vibration at different locations on the hindlimbs of mice.

  14. System for whole body imaging and count profiling with a scintillation camera

    International Nuclear Information System (INIS)

    Kaplan, E.; Cooke, M.B.D.

    1976-01-01

    The present invention relates to a method of and apparatus for the radionuclide imaging of the whole body of a patient using an unmodified scintillation camera which permits a patient to be continuously moved under or over the stationary camera face along one axis at a time, parallel passes being made to increase the dimension of the other axis. The system includes a unique electrical circuit which makes it possible to digitally generate new matrix coordinates by summing the coordinates of a first fixed reference frame and the coordinates of a second moving reference frame. 19 claims, 7 figures

  15. A 2-Tesla active shield magnet for whole body imaging and spectroscopy

    International Nuclear Information System (INIS)

    Davies, F.J.; Elliott, R.T.; Hawksworth, D.G.

    1991-01-01

    This paper reports on the development and testing of a 2T superconducting Active Shield magnet, with a 0.99m diameter warm bore for whole-body Magnetic Resonance Imaging (MRI) and spectroscopy. The magnet and cryostat were designed to meet the same performance standards as existing MRI magnets, but with the volume of the stray field region reduced to less than 4% of that for an unshielded magnet. The 0.5 mT stray field contour is within 5m axially and 3m radially of the magnet center. The system weight is only 14 tonnes

  16. Segmentation and visual analysis of whole-body mouse skeleton microSPECT

    NARCIS (Netherlands)

    Khmelinskii, A.; Groen, H.C.; De Jong, M.; Lelieveldt, B.P.F.

    2012-01-01

    Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality,

  17. Segmentation and Visual Analysis of Whole-Body Mouse Skeleton microSPECT

    NARCIS (Netherlands)

    A. Khmelinskii (Artem); H.C. Groen (Harald); M. Baiker (Martin); M. de Jong (Marion); B.P.F. Lelieveldt (Boudewijn)

    2012-01-01

    textabstractWhole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput,

  18. Constrained non-rigid registration for whole body image registration: method and validation

    Science.gov (United States)

    Li, Xia; Yankeelov, Thomas E.; Peterson, Todd E.; Gore, John C.; Dawant, Benoit M.

    2007-03-01

    3D intra- and inter-subject registration of image volumes is important for tasks that include measurements and quantification of temporal/longitudinal changes, atlas-based segmentation, deriving population averages, or voxel and tensor-based morphometry. A number of methods have been proposed to tackle this problem but few of them have focused on the problem of registering whole body image volumes acquired either from humans or small animals. These image volumes typically contain a large number of articulated structures, which makes registration more difficult than the registration of head images, to which the vast majority of registration algorithms have been applied. To solve this problem, we have previously proposed an approach, which initializes an intensity-based non-rigid registration algorithm with a point based registration technique [1, 2]. In this paper, we introduce new constraints into our non-rigid registration algorithm to prevent the bones from being deformed inaccurately. Results we have obtained show that the new constrained algorithm leads to better registration results than the previous one.

  19. In vivo quantification of {sup 177}Lu with planar whole-body and SPECT/CT gamma camera imaging

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, Dale L. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Faculty of Health Sciences, University of Sydney, Cumberland, NSW (Australia); Sydney Medical School, University of Sydney, Camperdown, NSW (Australia); NETwork, Sydney Vital, St Leonards, Sydney, NSW (Australia); Hennessy, Thomas M.; Willowson, Kathy P.; Henry, E. Courtney [Institute of Medical Physics, University of Sydney, Camperdown, NSW (Australia); Chan, David L.H. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); NETwork, Sydney Vital, St Leonards, Sydney, NSW (Australia); Aslani, Alireza [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Roach, Paul J. [Department of Nuclear Medicine, Royal North Shore Hospital, St Leonards, NSW 2065 (Australia); Sydney Medical School, University of Sydney, Camperdown, NSW (Australia)

    2015-09-17

    Advances in gamma camera technology and the emergence of a number of new theranostic radiopharmaceutical pairings have re-awakened interest in in vivo quantification with single-photon-emitting radionuclides. We have implemented and validated methodology to provide quantitative imaging of {sup 177}Lu for 2D whole-body planar studies and for 3D tomographic imaging with single-photon emission computed tomography (SPECT)/CT. Whole-body planar scans were performed on subjects to whom a known amount of [{sup 177}Lu]-DOTA-octreotate had been administered for therapy. The total radioactivity estimated from the images was compared with the known amount of the radionuclide therapy administered. In separate studies, venous blood samples were withdrawn from subjects after administration of [{sup 177}Lu]-DOTA-octreotate while a SPECT acquisition was in progress and the concentration of the radionuclide in the venous blood sample compared with that estimated from large blood pool structures in the SPECT reconstruction. The total radioactivity contained within an internal SPECT calibration standard was also assessed. In the whole-body planar scans (n = 28), the estimated total body radioactivity was accurate to within +4.6 ± 5.9 % (range −17.1 to +11.2 %) of the correct value. In the SPECT reconstructions (n = 12), the radioactivity concentration in the cardiac blood pool was accurate to within −4.0 ± 7.8 % (range −16.1 to +7.5 %) of the true value and the internal standard measurements (n = 89) were within 2.0 ± 8.5 % (range −16.3 to +24.2 %) of the known amount of radioactivity contained. In our hands, state-of-the-art hybrid SPECT/CT gamma cameras were able to provide accurate estimates of in vivo radioactivity to better than, on average, ±10 % for use in biodistribution and radionuclide dosimetry calculations.

  20. IRIS Toxicological Review of Thallium and Compounds ...

    Science.gov (United States)

    Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certain tumors. EPA's assessment of noncancer health effects and carcinogenic potential of thallium compounds was last prepared and added to the IRIS database between 1988 and 1990. The IRIS program is preparing an assessment that will incorporate current health effects information available for thallium and compounds, and current risk assessment methods. The IRIS assessment for thallium compounds will consist of a Toxicological Review and IRIS Summary. The Toxicological Review is a critical review of the physiochemical and toxicokinetic properties of a chemical, and its toxicity in humans and experimental systems. The assessment will present reference values for the noncancer effects of thallium compounds (RfD and Rfc), and a cancer assessment. The Toxicological Review and IRIS Summary have been subject to Agency review, Interagency review, and external scientific peer review. The final product will reflect the Agency opinion on the overall toxicity of thallium and compounds. EPA is undertaking an Integrated Risk Information System (IRIS) health assessment for thallium and compounds. IRIS is an EPA database containing Agency scientific positions on potential adverse human health effec

  1. Left ventricular dilatation and pulmonary thallium uptake after single-photon emission computer tomography using thallium-201 during adenosine-induced coronary hyperemia

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Heo, J.; Nguyen, T.; Lyons, E.; Paugh, E.

    1990-01-01

    This study examined the implications of left ventricular (LV) dilatation and increased pulmonary thallium uptake during adenosine-induced coronary hyperemia. The lung-to-heart thallium ratio in the initial images was significantly higher in patients with coronary artery disease (CAD) than normal subjects; 0.48 +/- 0.16 in 3-vessel disease (n = 16), 0.43 +/- 0.10 in 2-vessel disease (n = 20), 0.43 +/- 0.08 in 1-vessel disease (n = 16) and 0.36 +/- 0.05 in normal subjects (n = 7) (p less than 0.001, 0.09 and 0.06, respectively). There was a significant correlation between the severity and the extent of the perfusion abnormality (determined from the polar maps) and the lung-to-heart thallium ratio (r = 0.51 and 0.52, respectively, p less than 0.0002). There was also a significant correlation between lung thallium washout and lung-to-heart thallium ratio (r = 0.42, p = 0.0009) and peak heart rate (r = -0.49, p less than 0.0001). The LV dilatation was mostly due to an increase in cavity dimension (30% increase) and to a lesser extent (6% increase) due to increase in LV size. (The cavity dimensions were measured from the short-axis slices at the midventricular level in the initial and delayed images). The dilation was seen in patients with CAD but not in the normal subjects. These changes correlated with the extent and severity of the thallium perfusion abnormality. Thus, adenosine-induced coronary hyperemia may cause LV dilation and increased lung thallium uptake on the basis of subendocardial ischemia

  2. The cardiomyopathy in Friedreich's ataxia: isotopic ventriculography and myocardial imaging with thallium-201

    International Nuclear Information System (INIS)

    Therriault, L.; Lamoureux, G.; Cote, M.; Plourde, G.; Lemieux, B.

    1984-01-01

    Myocardial scanning after the intravenous administration of Thallium 201 was used to evaluate regional myocardial perfusion in 14 patients with Friedreich's ataxia. Isotopic ventriculography was also used to assess left ventricular contractility. Myocardial images in patients with Friedreich's ataxia were found to be precociously abnormal irrespective of the degree of neurological impairment or of the severity of myocardial hypertrophy

  3. Exercise thallium-201 scintigraphy in evaluating aortocoronary bypass surgery

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Haaz, W.; Segal, B.L.; Kane, S.A.

    1981-01-01

    Thirty patients with recurrent symptoms after aortocoronary bypass graft surgery underwent angiography as well as exercise thallium 201 imaging. Exercise imaging has been shown to be highly specific (100 percent in our study) in evaluating patients after bypass surgery. Patients with complete revascularization have normal thallium 201 images. Similarly, exercise-induced defects are seen only in the presence of incomplete revascularization. There are patients, however, with incomplete revascularization with normal exercise images, but these generally limited to the right coronary artery or the diagonal vessels or their grafts

  4. Thallium-201 myocardial imaging in young adults with anomalous left coronary artery arising from the pulmonary artery

    International Nuclear Information System (INIS)

    Moodie, D.S.; Cook, S.A.; Gill, C.C.; Napoli, C.A.

    1980-01-01

    Anomalous origin of the left coronary artery from the pulmonary artery (Bland-Garland-White syndrome) may produce myocardial ischemia, infarction, and frequently death in infancy. Some patients, however, develop satisfactory coronary artery collaterals and are relatively asymptomatic into adulthood. Very little is known about their myocardial perfusion patterns. We studied three young adults with this condition using stress thallium-201 myocardial imaging. Electrocardiograms in two patients demonstrated old arterolateral myocardial infarctions. Preoperative stress exercise tests were positive in all three patients. Marked perfusion abnormalities were found in the proximal anterolateral wall in all patients, and one patient also had a posterolateral defect. Postoperatively, all stress tests returned to normal. Thallium imaging demonstrated improvement in ischemic areas, but old scars persisted

  5. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array.

    Science.gov (United States)

    Yu, Zhicong; Leng, Shuai; Jorgensen, Steven M; Li, Zhoubo; Gutjahr, Ralf; Chen, Baiyu; Halaweish, Ahmed F; Kappler, Steffen; Yu, Lifeng; Ritman, Erik L; McCollough, Cynthia H

    2016-02-21

    This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x

  6. Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array

    International Nuclear Information System (INIS)

    Yu, Zhicong; Leng, Shuai; Li, Zhoubo; Chen, Baiyu; Yu, Lifeng; McCollough, Cynthia H; Jorgensen, Steven M; Ritman, Erik L; Gutjahr, Ralf; Kappler, Steffen; Halaweish, Ahmed F

    2016-01-01

    This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x

  7. Accuracy of whole-body low-dose multidetector CT (WBLDCT) versus skeletal survey in the detection of myelomatous lesions, and correlation of disease distribution with whole-body MRI (WBMRI).

    LENUS (Irish Health Repository)

    Gleeson, T G

    2009-03-01

    The aim of the study is to assess the feasibility of whole-body low-dose computed tomography (WBLDCT) in the diagnosis and staging of multiple myeloma and compare to skeletal survey (SS), using bone marrow biopsy and whole-body magnetic resonance imaging (WBMRI; where available) as gold standard.

  8. The contribution of the body and motion to whole person recognition.

    Science.gov (United States)

    Simhi, Noa; Yovel, Galit

    2016-05-01

    While the importance of faces in person recognition has been the subject of many studies, there are relatively few studies examining recognition of the whole person in motion even though this most closely resembles daily experience. Most studies examining the whole body in motion use point light displays, which have many advantages but are impoverished and unnatural compared to real life. To determine which factors are used when recognizing the whole person in motion we conducted two experiments using naturalistic videos. In Experiment 1 we used a matching task in which the first stimulus in each pair could either be a video or multiple still images from a video of the full body. The second stimulus, on which person recognition was performed, could be an image of either the full body or face alone. We found that the body contributed to person recognition beyond the face, but only after exposure to motion. Since person recognition was performed on still images, the contribution of motion to person recognition was mediated by form-from-motion processes. To assess whether dynamic identity signatures may also contribute to person recognition, in Experiment 2 we presented people in motion and examined person recognition from videos compared to still images. Results show that dynamic identity signatures did not contribute to person recognition beyond form-from-motion processes. We conclude that the face, body and form-from-motion processes all appear to play a role in unfamiliar person recognition, suggesting the importance of considering the whole body and motion when examining person perception. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Diagnostic value of transient dilatation of the left ventricle in negative dipyridamole-thallium imaging

    International Nuclear Information System (INIS)

    Seo, Hiromi; Doi, Y.L.; Yonezawa, Yoshihiro; Chikamori, Taishiro; Yamada, Mitsutoshi; Ozawa, Toshio

    1994-01-01

    To evaluate the diagnostic value of a transient dilatation of the left ventricle during dipyridamole-thallium imaging (DTI) for detecting significant coronary artery disease (CAD) in patients with negative DTI results, 81 consecutive patients were studied. Twenty one patients (26%) had CAD and 60 patients had normal coronary anatomy (NCA). The initial/delayed ratio of the left ventricular dimension, which was measured as the distance between the 2 peaks of a count profile curve on a 45deg left anterior oblique planar image, was defined as the dilatation ratio (DR) of the left ventricle. Patients with CAD had a higher incidence of chest pain after dipyridamole infusion (35 vs 13%; p 1.03) when it was greater than the mean +2 standard deviations of the DR in NCA patients. Seventy-six percent of CAD patients had an abnormal DR. A stepwise discriminant analysis revealed that an abnormal DR alone had the same ability to predict CAD (sensitivity 76%, specificity 98%, chi-square 80.9, p 1.03) is a highly specific marker for detecting CAD, even in patients with negative dipyridamole-thallium imaging. (author)

  10. Removal of thallium by deferasirox in rats as biological model.

    Science.gov (United States)

    Saljooghi, Amir Sh; Fatemi, S Jamiladin

    2011-03-01

    The present research aimed to characterize the potential efficiency of deferasirox in removing thallium after its administration for 30 days following two dose levels of 20 and 160 μm of thallium (III) chloride to male Wistar rats every day. After thallium administration some abnormal clinical signs such as red staining around the eyes, greenish mottling on the liver, weakness, loss of hair and weight, were observed in animals. Deferasirox was given orally to different groups of rats for a period of one week immediately after thallium administration. After chelation therapy, animals were killed by exsanguination from the abdominal aorta, and then thallium and iron concentrations in various tissues were determined by standard addition method. The chelation therapy results showed that deferasirox was able to remove thallium ions from the body and clinical symptoms were also reduced. Copyright © 2010 John Wiley & Sons, Ltd.

  11. Clinical study of 18F-FDG PET/CT whole-body imaging in disseminated carcinoma of unknown primary site

    International Nuclear Information System (INIS)

    Wang Guohui; Liang Peiyan; Cai Yanjun; Zhang Weiguang; Xie Chuanmiao; Wu Peihong

    2008-01-01

    Objective: Carcinoma of unknown primary (CUP) is not uncommon in usual clinical settings. They are, by definition, those cases with clinically suspected primary malignancy but not revealed by conventional investigation. The aim of this study was to investigate the efficacy of whole-body 18 F-fluoro- deoxyglucose (FDG) PET/CT in detecting a primary neoplasm for these patients. Methods: A totle of 150 patients with retrievable records from 169 CUP patients were selected within a group of consecutive 2589 patients from Jan. 2006 to Jun. 2007. All cases underwent whole-body FDG PET/CT scan. The final diagnoses were confirmed by pathologic results, other imaging modalities or clinical follow-up. Results: Among 150 patients, primary tumor sites were successfully detected by whole-body 18 F-FDG PET/CT scan in 70 cases (46.7%), of which 52 were pathologically confirmed and 18 by clinical follow-up. And 38 cases (54.3%) were lung cancer, 8 (11.4%) were nasopharyngeal carcinoma, 13 (18.6%) in digestive sys- tem, and 11 (15.7%) in other systems. Three clinically suspected CUP cases with negative 18 F-FDG PET/ CT were subsequently confirmed of benign processes by clinical follow-up. Six patients were wrongly diagnosed by 18 F-FDG PET/CT, and 15 patients did not have a confirmed diagnosis by the end of research. The primary cause of malignancy after 18 F-FDG PET/CT remained obscure in 56 patients, only 3 of whom be- came known during the course of clinical follow-up (nasopharyngeal bladder and esophageal carcinoma). Conclusion: 18 F-FDG PET/CT whole-body imaging plays an important role in patients with metastatic CUP. (authors)

  12. Noninvasive external cardiac pacing for thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Feldman, M.D.; Warren, S.E.; Gervino, E.V.

    1988-01-01

    Improvements in noninvasive external cardiac pacing have led to a technique with reliable electrical capture and tolerable patient discomfort. To assess the use of this modality of pacing in combination with thallium scintigraphy as a noninvasive pacing stress test, we applied simultaneous noninvasive cardiac pacing, hemodynamic monitoring, and thallium-201 scintigraphy in 14 patients undergoing cardiac catheterization for chest pain syndromes. Two patients had normal coronary arteries, while the remaining 12 had significant coronary artery disease. Thallium scintigraphic responses to pacing were compared to routine exercise thallium stress testing in nine of these 14 patients. All patients were noninvasively paced to more than 85% of the age-predicted maximum heart rate. Twelve patients demonstrated reversible thallium defects, which corresponded in 11 cases to significant lesions seen on coronary angiography. Of nine patients who underwent both pacing and exercise thallium stress tests, comparable maximal rate-pressure products were achieved. Moreover, thallium imaging at peak pacing and during delayed views did not differ significantly from exercise thallium scintigraphy. A limiting factor associated with the technique was local patient discomfort, which occurred to some degree in all patients. We conclude that noninvasive external cardiac pacing together with thallium scintigraphy is capable of detecting significant coronary artery disease and may be comparable to routine exercise thallium stress testing. This new modality of stress testing could be useful in patients unable to undergo the exercise required for standard exercise tolerance testing, particularly if improvements in the technology can be found to reduce further the local discomfort

  13. Prospective, blinded trial of whole-body magnetic resonance imaging versus computed tomography positron emission tomography in staging primary and recurrent cancer of the head and neck.

    LENUS (Irish Health Repository)

    O'Neill, J P

    2012-02-01

    OBJECTIVES: To compare the use of computed tomography - positron emission tomography and whole-body magnetic resonance imaging for the staging of head and neck cancer. PATIENTS AND METHODS: From January to July 2009, 15 consecutive head and neck cancer patients (11 men and four women; mean age 59 years; age range 19 to 81 years) underwent computed tomography - positron emission tomography and whole-body magnetic resonance imaging for pre-therapeutic evaluation. All scans were staged, as per the American Joint Committee on Cancer tumour-node-metastasis classification, by two blinded consultant radiologists, in two sittings. Diagnoses were confirmed by histopathological examination of endoscopic biopsies, and in some cases whole surgical specimens. RESULTS: Tumour staging showed a 74 per cent concordance, node staging an 80 per cent concordance and metastasis staging a 100 per cent concordance, comparing the two imaging modalities. CONCLUSION: This study found radiological staging discordance between the two imaging modalities. Whole-body magnetic resonance imaging is an emerging staging modality with superior visualisation of metastatic disease, which does not require exposure to ionising radiation.

  14. Exercise thallium testing in ventricular preexcitation

    Energy Technology Data Exchange (ETDEWEB)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-05-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation.

  15. Exercise thallium testing in ventricular preexcitation

    International Nuclear Information System (INIS)

    Archer, S.; Gornick, C.; Grund, F.; Shafer, R.; Weir, E.K.

    1987-01-01

    Ventricular preexcitation, as seen in Wolff-Parkinson-White syndrome, results in a high frequency of positive exercise electrocardiographic responses. Why this occurs is unknown but is not believed to reflect myocardial ischemia. Exercise thallium testing is often used for noninvasive assessment of coronary artery disease in patients with conditions known to result in false-positive electrocardiographic responses. To assess the effects of ventricular preexcitation on exercise thallium testing, 8 men (aged 42 +/- 4 years) with this finding were studied. No subject had signs or symptoms of coronary artery disease. Subjects exercised on a bicycle ergometer to a double product of 26,000 +/- 2,000 (+/- standard error of mean). All but one of the subjects had at least 1 mm of ST-segment depression. Tests were terminated because of fatigue or dyspnea and no patient had chest pain. Thallium test results were abnormal in 5 patients, 2 of whom had stress defects as well as abnormally delayed thallium washout. One of these subjects had normal coronary arteries on angiography with a negative ergonovine challenge, and both had normal exercise radionuclide ventriculographic studies. Delayed thallium washout was noted in 3 of the subjects with ventricular preexcitation and normal stress images. This study suggests that exercise thallium testing is frequently abnormal in subjects with ventricular preexcitation. Ventricular preexcitation may cause dyssynergy of ventricular activation, which could alter myocardial thallium handling, much as occurs with left bundle branch block. Exercise radionuclide ventriculography may be a better test for noninvasive assessment of coronary artery disease in patients with ventricular preexcitation

  16. Evaluation of myocardial fatty acid metabolism in the area of fill-in after thallium reinjection in patients with prior myocardial infarction

    International Nuclear Information System (INIS)

    Matsunari, Ichiro; Fujino, Susumu; Nishikawa, Takahiro; Ichiyanagi, Kenji; Taki, Junichi; Nakajima, Kenichi; Tonami, Norihisa; Hisada, Kinichi.

    1995-01-01

    Myocardial fatty acid utilization in the area with thallium fill-in after reinjection was assessed using 123 I-labeled 15-(p-iodophenyl) 3R, S-methylpentadecanoic acid (BMIPP). We studied 22 patients with prior myocardial infarction that revealed persistent defects on standard exercise-redistribution thallium imaging. In each patient, exercise-redistribution-reinjection thallium imaging was performed. Within two weeks of the thallium study, resting BMIPP imaging was performed 20 min after injection of BMIPP (148 MBq). Following qualitative analysis of the obtained thallium and BMIPP images, quantitative analysis was performed on the basis of relative regional uptake. Of 199 myocardial segments that showed persistent defects on exercise-redistribution images, 73 segments showed apparent fill-in on the reinjection images (fill-in positive), and the remaining 126 segments did not (fill-in negative). When BMIPP images were compared with the corresponding thallium reinjection images, reduced BMIPP uptake compared with thallium was frequently observed in the area of fill-in positive segments (65 of 73 segments, 89%). Quantitative analysis also showed decrease in BMIPP activity compared to thallium activity in the area of fill-in (49.7±16.1 vs. 65.8±16.0%, p<0.001). In contrast, only 24 of the 126 fill-in negative segments (19%) showed lower BMIPP uptake than thallium. These results suggest that impaired fatty acid utilization in the area of thallium new fill-in after reinjection already exists at resting condition. Thus, BMIPP imaging combined with exercise-redistribution-reinjection thallium imaging provides insights to understanding fatty acid utilization in ischemic but viable myocardium identified by thallium reinjection in patients with prior myocardial infarction. (author)

  17. Swimming clusters in thallium-rich liquid caesium-thallium alloys

    NARCIS (Netherlands)

    van der Aart, SA; van der Lugt, W; Badyal, YS; Verkerk, P

    The purpose of the work presented here is to obtain structural information on thallium-rich caesium-thallium alloys by means of neutron diffraction. The alloys exhibit a long-range (>1 nm) superstructure. This range increases with the thallium content. The results are interpreted with the help of a

  18. Anatomical and metabolic small-animal whole-body imaging using ring-shaped confocal photoacoustic computed tomography

    Science.gov (United States)

    Xia, Jun; Chatni, Muhammad; Maslov, Konstantin; Wang, Lihong V.

    2013-03-01

    Due to the wide use of animals for human disease studies, small animal whole-body imaging plays an increasingly important role in biomedical research. Currently, none of the existing imaging modalities can provide both anatomical and glucose metabolic information, leading to higher costs of building dual-modality systems. Even with image coregistration, the spatial resolution of the metabolic imaging modality is not improved. We present a ring-shaped confocal photoacoustic computed tomography (RC-PACT) system that can provide both assessments in a single modality. Utilizing the novel design of confocal full-ring light delivery and ultrasound transducer array detection, RC-PACT provides full-view cross-sectional imaging with high spatial resolution. Scanning along the orthogonal direction provides three-dimensional imaging. While the mouse anatomy was imaged with endogenous hemoglobin contrast, the glucose metabolism was imaged with a near-infrared dye-labeled 2-deoxyglucose. Through mouse tumor models, we demonstrate that RC-PACT may be a paradigm shifting imaging method for preclinical research.

  19. Whole body traveling wave magnetic resonance imaging at high field strength: homogeneity, efficiency, and energy deposition as compared with traditional excitation mechanisms.

    Science.gov (United States)

    Zhang, Bei; Sodickson, Daniel K; Lattanzi, Riccardo; Duan, Qi; Stoeckel, Bernd; Wiggins, Graham C

    2012-04-01

    In 7 T traveling wave imaging, waveguide modes supported by the scanner radiofrequency shield are used to excite an MR signal in samples or tissue which may be several meters away from the antenna used to drive radiofrequency power into the system. To explore the potential merits of traveling wave excitation for whole-body imaging at 7 T, we compare numerical simulations of traveling wave and TEM systems, and juxtapose full-wave electrodynamic simulations using a human body model with in vivo human traveling wave imaging at multiple stations covering the entire body. The simulated and in vivo traveling wave results correspond well, with strong signal at the periphery of the body and weak signal deep in the torso. These numerical results also illustrate the complicated wave behavior that emerges when a body is present. The TEM resonator simulation allowed comparison of traveling wave excitation with standard quadrature excitation, showing that while the traveling wave B +1 per unit drive voltage is much less than that of the TEM system, the square of the average B +1 compared to peak specific absorption rate (SAR) values can be comparable in certain imaging planes. Both systems produce highly inhomogeneous excitation of MR signal in the torso, suggesting that B(1) shimming or other parallel transmission methods are necessary for 7 T whole body imaging. Copyright © 2011 Wiley-Liss, Inc.

  20. First results in postoperative functional imaging of parathyroid tissue with thallium-201-chloride

    International Nuclear Information System (INIS)

    Schwartz, K.D.; Michael, R.; Karsten, U.; Pietsch, P.; Brietzke, W.; Tredt, H.J.; Dabels, J.; Labes, K.

    1984-01-01

    On account of diagnostic uncertainties Se-75-methionine failed to become accepted clinically for detecting parathyroid adenomas. But recent reports in the literature suggested satisfactory results to be achieved with a double-nuclide technique using Thallium-201-chloride for parathyroid imaging. Data of 6 patients were evaluated to shed light on the usefulness of radio-Thallium for postoperative functional imaging of heterotopic parathyroid tissue. Analogous studies using Se-75-methionine had previously been carried out by other authors. Early results suggest the method to have clinical relavance. Four patients with cubital vein parathormone levels that were higher on the grafted versus the ungrafted side were found to have significantly elevated Tl-201 uptake in the region of the surgical scar on the forearm. Two patients with no or little difference in PTH concentrations between the 2 sides showed no or at best some slight activity increase. The place of this method as an alternative to differential cubital vein parathormone assaying still remains to be established. In view of the poor cubital veins of dialysis patients it appears to hold promises for assessing the function of parathyroid grafts in the forearm. (Author)

  1. Effect of exercise supplementation on dipyridamole thallium-201 image quality

    International Nuclear Information System (INIS)

    Stern, S.; Greenberg, I.D.; Corne, R.

    1991-01-01

    To determine the effect of different types of exercise supplementation on dipyridamole thallium image quality, 78 patients were prospectively randomized to one of three protocols: dipyridamole infusion alone, dipyridamole supplemented with isometric handgrip, and dipyridamole with low-level treadmill exercise. Heart-to-lung, heart-to-liver, and heart-to-adjacent infradiaphragmatic activity ratios were generated from anterior images acquired immediately following the test. Additionally, heart-to-total infradiaphragmatic activity was graded semiquantitatively. Results showed a significantly higher ratio of heart to subdiaphragmatic activity in the treadmill group as compared with dipyridamole alone (p less than 0.001) and dipyridamole supplemented with isometric handgrip exercise (p less than 0.001). No significant difference was observed between patients receiving the dipyridamole infusion, and dipyridamole supplemented with isometric handgrip exercise. The authors conclude that low-level treadmill exercise supplementation of dipyridamole infusion is an effective means of improving image quality. Supplementation with isometric handgrip does not improve image quality over dipyridamole alone

  2. Whole-body biodistribution and dosimetry estimates of a novel radiotracer for imaging of serotonin 4 receptors in brain: [18F]MNI-698

    International Nuclear Information System (INIS)

    Tavares, Adriana Alexandre S.; Caillé, Fabien; Barret, Olivier; Papin, Caroline; Lee, Hsiaoju; Morley, Thomas J.; Fowles, Krista; Holden, Daniel; Seibyl, John P.; Alagille, David; Tamagnan, Gilles D.

    2014-01-01

    Introduction: A new radiotracer for imaging the serotonin 4 receptors (5-HT 4 ) in brain, [ 18 F]MNI-698, was recently developed by our group. Evaluation in nonhuman primates indicates the novel radiotracer holds promise as an imaging agent of 5-HT 4 in brain. This paper aims to describe the whole-body biodistribution and dosimetry estimates of [ 18 F]MNI-698. Methods: Whole-body positron emission tomography (PET) images were acquired over 240 minutes after intravenous bolus injection of [ 18 F]MNI-698 in adult rhesus monkeys. Different models were investigated for quantification of radiation absorbed and effective doses using OLINDA/EXM 1.0 software. Results: The radiotracer main elimination route was found to be urinary and the critical organ was the urinary bladder. Modeling of the urinary bladder voiding interval had a considerable effect on the estimated effective dose. Normalization of rhesus monkeys’ organs and whole-body masses to human equivalent reduced the calculated dosimetry values. The effective dose ranged between 0.017 and 0.027 mSv/MBq. Conclusion: The dosimetry estimates, obtained when normalizing organ and whole-body weights and applying the urinary bladder model, indicate that the radiation doses from [ 18 F]MNI-698 comply with limits and guidelines recommended by key regulatory authorities that govern the translation of radiotracers to human clinical trials. The timing of urinary bladder emptying should be considered when designing future clinical protocols with [ 18 F]MNI-698, in order to minimize the subject absorbed doses

  3. A gamma camera count rate saturation correction method for whole-body planar imaging

    Science.gov (United States)

    Hobbs, Robert F.; Baechler, Sébastien; Senthamizhchelvan, Srinivasan; Prideaux, Andrew R.; Esaias, Caroline E.; Reinhardt, Melvin; Frey, Eric C.; Loeb, David M.; Sgouros, George

    2010-02-01

    Whole-body (WB) planar imaging has long been one of the staple methods of dosimetry, and its quantification has been formalized by the MIRD Committee in pamphlet no 16. One of the issues not specifically addressed in the formalism occurs when the count rates reaching the detector are sufficiently high to result in camera count saturation. Camera dead-time effects have been extensively studied, but all of the developed correction methods assume static acquisitions. However, during WB planar (sweep) imaging, a variable amount of imaged activity exists in the detector's field of view as a function of time and therefore the camera saturation is time dependent. A new time-dependent algorithm was developed to correct for dead-time effects during WB planar acquisitions that accounts for relative motion between detector heads and imaged object. Static camera dead-time parameters were acquired by imaging decaying activity in a phantom and obtaining a saturation curve. Using these parameters, an iterative algorithm akin to Newton's method was developed, which takes into account the variable count rate seen by the detector as a function of time. The algorithm was tested on simulated data as well as on a whole-body scan of high activity Samarium-153 in an ellipsoid phantom. A complete set of parameters from unsaturated phantom data necessary for count rate to activity conversion was also obtained, including build-up and attenuation coefficients, in order to convert corrected count rate values to activity. The algorithm proved successful in accounting for motion- and time-dependent saturation effects in both the simulated and measured data and converged to any desired degree of precision. The clearance half-life calculated from the ellipsoid phantom data was calculated to be 45.1 h after dead-time correction and 51.4 h with no correction; the physical decay half-life of Samarium-153 is 46.3 h. Accurate WB planar dosimetry of high activities relies on successfully compensating

  4. Evaluation of brain and whole-body pharmacokinetics of 11C-labeled diphenylhydantoin in rats by means of planar positron imaging system

    International Nuclear Information System (INIS)

    Hasegawa, Yukinori; Kanai, Yasukazu; Hasegawa, Shinji; Shimosegawa, Eku; Kurachi, Yoshihisa; Hatazawa, Jun; Okamoto, Takashi; Matsui, Tamiko

    2008-01-01

    A planar positron imaging system (PPIS) enables whole-body dynamic imaging of radiopharmaceuticals labeled with positron-emitting nuclides. We evaluated the difference in the brain and whole-body pharmacokinetics of 11 C-diphenylhydantoin ( 11 C-DPH) between intravenous and duodenal administration in rats. Male Wistar rats (8 weeks old, mean body weight 250 g) were examined under anesthesia. A tracer amount of 11 C-DPH (2 μg or less; about 5 MBq) was injected into the tail vein (n=3) or duodenum (n=3). Immediately following the administration, PPIS scans were obtained for 20 min. Regions of interest (ROIs) were set on the brain, heart, liver, intestinal field, and urinary bladder, identified on the integrated images. The relative uptake value (RUV, %) was calculated as the regional count divided by the whole-body count multiplied by 100. Sequential changes in the RUV for each ROI were analyzed for the brain and other organs. Following intravenous injection of 11 C-DPH, the RUV in the brain was 1.59±0.07%, 1.53±0.09%, 1.40±0.09%, and 1.38±0.08% at 5 min, 10 min, 15 min, and 20 min after the injection, respectively. After duodenal administration, the corresponding values were 0.54±0.16%, 1.01±0.12%, 1.43±0.24%, and 1.52±0.06%, respectively. The 11 C-DPH distribution was significantly lower at 5 min and 10 min following duodenal administration than after intravenous injection (P 11 C-DPH between intravenous and duodenal administration in rats. Use of the PPIS is feasible for the evaluation of the pharmacokinetics in both the target organ and the whole body in small animals. (author)

  5. Whole-body gene expression pattern registration in Platynereis larvae.

    Science.gov (United States)

    Asadulina, Albina; Panzera, Aurora; Verasztó, Csaba; Liebig, Christian; Jékely, Gáspár

    2012-12-03

    Digital anatomical atlases are increasingly used in order to depict different gene expression patterns and neuronal morphologies within a standardized reference template. In evo-devo, a discipline in which the comparison of gene expression patterns is a widely used approach, such standardized anatomical atlases would allow a more rigorous assessment of the conservation of and changes in gene expression patterns during micro- and macroevolutionary time scales. Due to its small size and invariant early development, the annelid Platynereis dumerilii is particularly well suited for such studies. Recently a reference template with registered gene expression patterns has been generated for the anterior part (episphere) of the Platynereis trochophore larva and used for the detailed study of neuronal development. Here we introduce and evaluate a method for whole-body gene expression pattern registration for Platynereis trochophore and nectochaete larvae based on whole-mount in situ hybridization, confocal microscopy, and image registration. We achieved high-resolution whole-body scanning using the mounting medium 2,2'-thiodiethanol (TDE), which allows the matching of the refractive index of the sample to that of glass and immersion oil thereby reducing spherical aberration and improving depth penetration. This approach allowed us to scan entire whole-mount larvae stained with nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP) in situ hybridization and counterstained fluorescently with an acetylated-tubulin antibody and the nuclear stain 4'6-diamidino-2-phenylindole (DAPI). Due to the submicron isotropic voxel size whole-mount larvae could be scanned in any orientation. Based on the whole-body scans, we generated four different reference templates by the iterative registration and averaging of 40 individual image stacks using either the acetylated-tubulin or the nuclear-stain signal for each developmental stage. We then registered to these templates the

  6. Whole-body gene expression pattern registration in Platynereis larvae

    Directory of Open Access Journals (Sweden)

    Asadulina Albina

    2012-12-01

    Full Text Available Abstract Background Digital anatomical atlases are increasingly used in order to depict different gene expression patterns and neuronal morphologies within a standardized reference template. In evo-devo, a discipline in which the comparison of gene expression patterns is a widely used approach, such standardized anatomical atlases would allow a more rigorous assessment of the conservation of and changes in gene expression patterns during micro- and macroevolutionary time scales. Due to its small size and invariant early development, the annelid Platynereis dumerilii is particularly well suited for such studies. Recently a reference template with registered gene expression patterns has been generated for the anterior part (episphere of the Platynereis trochophore larva and used for the detailed study of neuronal development. Results Here we introduce and evaluate a method for whole-body gene expression pattern registration for Platynereis trochophore and nectochaete larvae based on whole-mount in situ hybridization, confocal microscopy, and image registration. We achieved high-resolution whole-body scanning using the mounting medium 2,2’-thiodiethanol (TDE, which allows the matching of the refractive index of the sample to that of glass and immersion oil thereby reducing spherical aberration and improving depth penetration. This approach allowed us to scan entire whole-mount larvae stained with nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP in situ hybridization and counterstained fluorescently with an acetylated-tubulin antibody and the nuclear stain 4’6-diamidino-2-phenylindole (DAPI. Due to the submicron isotropic voxel size whole-mount larvae could be scanned in any orientation. Based on the whole-body scans, we generated four different reference templates by the iterative registration and averaging of 40 individual image stacks using either the acetylated-tubulin or the nuclear-stain signal for each developmental

  7. Quantification of leg muscle perfusion using thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Oshima, M.; Akanabe, H.; Sakuma, S.; Yano, T.; Nishikimi, N.; Shionoya, S.

    1989-01-01

    The purpose of this study is to quantify leg muscle perfusion with 201 Tl single photon emission computed tomography (SPECT). Six normal controls and 21 patients with peripheral arterial disease underwent this examination. Thallium-201 leg SPECT of both stress and redistribution was performed using a dual-headed digital gamma camera. Each slice of transverse images was normalized with pixels and whole-body counts. In normal controls, the activity of posterior tibial muscle components was significantly higher than that of anterior tibial muscle components (p less than 0.001). In 14 components, where patients had insignificant lesions, profile curves were normal in 10 (71%). In 62 components, where patients had arteriographically significant lesions, stress profile curves were abnormal in 57 (92%) compared with normal controls. Approximately, in half (28/62) components which had significant lesions, profile curves showed redistribution after 3 hr compared with normal redistribution curves. In three patients who underwent successful bypass graftings, the activity of each muscle component returned to a normal range

  8. Quantitative analysis of thallium-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Kanemoto, Nariaki; Hoer, G.; Johost, S.; Maul, F.-D.; Standke, R.

    1981-01-01

    The method of quantitative analysis of thallium-201 myocardial scintigraphy using computer assisted technique was described. Calculated indices are washout factor, vitality index and redistribution factor. Washout factor is the ratio of counts at certain period of time after exercise and immediately after exercise. This value is neccessary for the evaluation of redistribution to the ischemic areas in serial imagings to correct the Tl-201 washout from the myocardium under the assumption that the washout is constant in the whole myocardium. Vitality index is the ratio between the Tl-201 uptake in the region of interest and that of the maximum. Redistribution factor is the ratio of the redistribution in the region of interest in serial imagings after exercise to that of immediately after exercise. Four examples of exercise Tl-201 myocardial scintigrams and the quantitative analyses before and after the percutaneous transluminal coronary angioplasty were presented. (author)

  9. Influence of detector pixel size, TOF resolution and DOI on image quality in MR-compatible whole-body PET.

    Science.gov (United States)

    Thoen, Hendrik; Keereman, Vincent; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2013-09-21

    The optimization of a whole-body PET system remains a challenging task, as the imaging performance is influenced by a complex interaction of different design parameters. However, it is not always clear which parameters have the largest impact on image quality and are most eligible for optimization. To determine this, we need to be able to assess their influence on image quality. We performed Monte-Carlo simulations of a whole-body PET scanner to predict the influence on image quality of three detector parameters: the TOF resolution, the transverse pixel size and depth-of-interaction (DOI)-correction. The inner diameter of the PET scanner was 65 cm, small enough to allow physical integration into a simultaneous PET-MR system. Point sources were used to evaluate the influence of transverse pixel size and DOI-correction on spatial resolution as function of radial distance. To evaluate the influence on contrast recovery and pixel noise a cylindrical phantom of 35 cm diameter was used, representing a large patient. The phantom contained multiple hot lesions with 5 mm diameter. These lesions were placed at radial distances of 50, 100 and 150 mm from the center of the field-of-view, to be able to study the effects at different radial positions. The non-prewhitening (NPW) observer was used for objective analysis of the detectability of the hot lesions in the cylindrical phantom. Based on this analysis the NPW-SNR was used to quantify the relative improvements in image quality due to changes of the variable detector parameters. The image quality of a whole-body PET scanner can be improved significantly by reducing the transverse pixel size from 4 to 2.6 mm and improving the TOF resolution from 600 to 400 ps and further from 400 to 200 ps. Compared to pixel size, the TOF resolution has the larger potential to increase image quality for the simulated phantom. The introduction of two layer DOI-correction only leads to a modest improvement for the spheres at radial

  10. Influence of detector pixel size, TOF resolution and DOI on image quality in MR-compatible whole-body PET

    International Nuclear Information System (INIS)

    Thoen, Hendrik; Keereman, Vincent; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2013-01-01

    The optimization of a whole-body PET system remains a challenging task, as the imaging performance is influenced by a complex interaction of different design parameters. However, it is not always clear which parameters have the largest impact on image quality and are most eligible for optimization. To determine this, we need to be able to assess their influence on image quality. We performed Monte-Carlo simulations of a whole-body PET scanner to predict the influence on image quality of three detector parameters: the TOF resolution, the transverse pixel size and depth-of-interaction (DOI)-correction. The inner diameter of the PET scanner was 65 cm, small enough to allow physical integration into a simultaneous PET-MR system. Point sources were used to evaluate the influence of transverse pixel size and DOI-correction on spatial resolution as function of radial distance. To evaluate the influence on contrast recovery and pixel noise a cylindrical phantom of 35 cm diameter was used, representing a large patient. The phantom contained multiple hot lesions with 5 mm diameter. These lesions were placed at radial distances of 50, 100 and 150 mm from the center of the field-of-view, to be able to study the effects at different radial positions. The non-prewhitening (NPW) observer was used for objective analysis of the detectability of the hot lesions in the cylindrical phantom. Based on this analysis the NPW-SNR was used to quantify the relative improvements in image quality due to changes of the variable detector parameters. The image quality of a whole-body PET scanner can be improved significantly by reducing the transverse pixel size from 4 to 2.6 mm and improving the TOF resolution from 600 to 400 ps and further from 400 to 200 ps. Compared to pixel size, the TOF resolution has the larger potential to increase image quality for the simulated phantom. The introduction of two layer DOI-correction only leads to a modest improvement for the spheres at radial distance of

  11. Occult primary tumors of the head and neck: accuracy of thallium 201 single-photon emission computed tomography and computed tomography and/or magnetic resonance imaging

    NARCIS (Netherlands)

    van Veen, S. A.; Balm, A. J.; Valdés Olmos, R. A.; Hoefnagel, C. A.; Hilgers, F. J.; Tan, I. B.; Pameijer, F. A.

    2001-01-01

    To determine the accuracy of thallium 201 single-photon emission computed tomography (thallium SPECT) and computed tomography and/or magnetic resonance imaging (CT/MRI) in the detection of occult primary tumors of the head and neck. Study of diagnostic tests. National Cancer Institute, Amsterdam,

  12. Clinical utility of simultaneous whole-body 18F-FDG PET/MRI as a single-step imaging modality in the staging of primary nasopharyngeal carcinoma.

    Science.gov (United States)

    Chan, Sheng-Chieh; Yeh, Chih-Hua; Yen, Tzu-Chen; Ng, Shu-Hang; Chang, Joseph Tung-Chieh; Lin, Chien-Yu; Yen-Ming, Tsang; Fan, Kang-Hsing; Huang, Bing-Shen; Hsu, Cheng-Lung; Chang, Kai-Ping; Wang, Hung-Ming; Liao, Chun-Ta

    2018-03-03

    Both head and neck magnetic resonance imaging (MRI) and 18F-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) play a crucial role in the staging of primary nasopharyngeal carcinoma (NPC). In this study, we sought to prospectively investigate the clinical utility of simultaneous whole-body 18F-FDG PET/MRI for primary staging of NPC patients. We examined 113 patients with histologically confirmed NPC who underwent pretreatment, simultaneous whole-body PET/MRI and PET/CT for primary tumor staging. The images obtained with the different imaging modalities were interpreted independently and compared with each other. PET/MRI increased the accuracy of head and neck MRI for assessment of primary tumor extent in four patients via addition of FDG uptake information to increase the conspicuity of morphologically subtle lesions. PET/MR images were more discernible than PET/CT images for mapping tumor extension, especially intracranial invasion. Regarding the N staging assessment, the sensitivity of PET/MRI (99.5%) was higher than that of head and neck MRI (94.2%) and PET/CT (90.9%). PET/MRI was particularly useful for distinguishing retropharyngeal nodal metastasis from adjacent nasopharyngeal tumors. For distant metastasis evaluation, PET/MRI exhibited a similar sensitivity (90% vs. 86.7% vs. 83.3%), but higher positive predictive value (93.1% vs. 78.8% vs. 83.3%) than whole-body MRI and PET/CT, respectively. For tumor staging of NPC, simultaneous whole-body PET/MRI was more accurate than head and neck MRI and PET/CT, and may serve as a single-step staging modality.

  13. Simultaneous low level treadmill exercise and intravenous dipyridamole stress thallium imaging

    International Nuclear Information System (INIS)

    Casale, P.N.; Guiney, T.E.; Strauss, H.W.; Boucher, C.A.

    1988-01-01

    Intravenous dipyridamole-thallium imaging unmasks ischemia in patients unable to exercise adequately. However, some of these patients can perform limited exercise, which, if added, may provide useful information. Treadmill exercise combined with dipyridamole-thallium imaging was performed in 100 patients and results compared with those of 100 other blindly age- and sex-matched patients who received dipyridamole alone. Exercise began after completion of the dipyridamole infusion. Mean +/- 1 standard deviation peak heart rate (109 +/- 19 vs 83 +/- 12 beats/min, p less than 0.0001) and peak systolic and diastolic blood pressure (146 +/- 28/77 +/- 14 vs 125 +/- 24/68 +/- 11 mm Hg, p less than 0.0001) were higher in the exercise group compared with the nonexercise group. There was no difference in the occurrence of chest pain, but more patients in the exercise group developed ST-segment depression (26 vs 12%, p less than 0.0001). The exercise group had fewer noncardiac side effects (4 vs 12%, p less than 0.01) and a higher target (heart) to background (liver) count ratio (2.1 +/- 0.7 vs 1.2 +/- 0.3; p less than 0.01), due to fewer liver counts. There were no deaths, myocardial infarctions or sustained arrhythmias in either group. Combined treadmill exercise and dipyridamole testing is safe, associated with fewer noncardiac side effects, a higher target to background ratio and a higher incidence of clinical electrocardiographic ischemia than dipyridamole alone. Therefore, it is recommended whenever possible

  14. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Brim, C.P.; Rieksts, G.A.; Rhoads, M.C.

    1987-05-01

    This document, a reprint of the Whole Body Counting Manual, was compiled to train personnel, document operation procedures, and outline quality assurance procedures. The current manual contains information on: the location, availability, and scope of services of Hanford's whole body counting facilities; the administrative aspect of the whole body counting operation; Hanford's whole body counting facilities; the step-by-step procedure involved in the different types of in vivo measurements; the detectors, preamplifiers and amplifiers, and spectroscopy equipment; the quality assurance aspect of equipment calibration and recordkeeping; data processing, record storage, results verification, report preparation, count summaries, and unit cost accounting; and the topics of minimum detectable amount and measurement accuracy and precision. 12 refs., 13 tabs

  15. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Izquierdo-Garcia, David [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Athinoula A. Martinos Center for Biomedical Imaging, Charlestown, MA (United States); Sawiak, Stephen J. [University of Cambridge, Wolfson Brain Imaging Centre, Cambridge (United Kingdom); Knesaurek, Karin; Machac, Joseph [Mount Sinai School of Medicine, Division of Nuclear Medicine, Department of Radiology, New York, NY (United States); Narula, Jagat [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Fuster, Valentin [Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); The Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid (Spain); Fayad, Zahi A. [Mount Sinai School of Medicine, Translational and Molecular Imaging Institute, New York, NY (United States); Mount Sinai School of Medicine, Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute and Marie-Josee and Henry R. Kravis Cardiovascular Health Center, New York, NY (United States); Mount Sinai School of Medicine, Department of Radiology, New York, NY (United States)

    2014-08-15

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R{sup 2} = 0.98, p < 0.001; beta group 10.31 ± 69.86 %, R{sup 2} = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  16. Comparison of MR-based attenuation correction and CT-based attenuation correction of whole-body PET/MR imaging

    International Nuclear Information System (INIS)

    Izquierdo-Garcia, David; Sawiak, Stephen J.; Knesaurek, Karin; Machac, Joseph; Narula, Jagat; Fuster, Valentin; Fayad, Zahi A.

    2014-01-01

    The objective of this study was to evaluate the performance of the built-in MR-based attenuation correction (MRAC) included in the combined whole-body Ingenuity TF PET/MR scanner and compare it to the performance of CT-based attenuation correction (CTAC) as the gold standard. Included in the study were 26 patients who underwent clinical whole-body FDG PET/CT imaging and subsequently PET/MR imaging (mean delay 100 min). Patients were separated into two groups: the alpha group (14 patients) without MR coils during PET/MR imaging and the beta group (12 patients) with MR coils present (neurovascular, spine, cardiac and torso coils). All images were coregistered to the same space (PET/MR). The two PET images from PET/MR reconstructed using MRAC and CTAC were compared by voxel-based and region-based methods (with ten regions of interest, ROIs). Lesions were also compared by an experienced clinician. Body mass index and lung density showed significant differences between the alpha and beta groups. Right and left lung densities were also significantly different within each group. The percentage differences in uptake values using MRAC in relation to those using CTAC were greater in the beta group than in the alpha group (alpha group -0.2 ± 33.6 %, R 2 = 0.98, p 2 = 0.97, p < 0.001). In comparison to CTAC, MRAC led to underestimation of the PET values by less than 10 % on average, although some ROIs and lesions did differ by more (including the spine, lung and heart). The beta group (imaged with coils present) showed increased overall PET quantification as well as increased variability compared to the alpha group (imaged without coils). PET data reconstructed with MRAC and CTAC showed some differences, mostly in relation to air pockets, metallic implants and attenuation differences in large bone areas (such as the pelvis and spine) due to the segmentation limitation of the MRAC method. (orig.)

  17. Myocardial imaging with thallium-201: an experimental model for analysis of the true myocardial and background image components

    International Nuclear Information System (INIS)

    Narahara, K.A.; Hamilton, G.W.; Williams, D.L.; Gould, K.L.

    1977-01-01

    The true myocardial and background components of a resting thallium-201 myocardial image were determined in an experimental dog model. True background was determined by imaging after the heart had been removed and replaced with a water-filled balloon of equal size and shape. In all studies, the background estimated from the region surrounding the heart exceeded true background activity. Furthermore, the relationship between true myocardial background and that estimated from the pericardiac region was inconsistent. Background estimates based on the activity surrounding the heart were not accurate predictors of true background activity

  18. Tardily accelerated neurologic deterioration in two-step thallium intoxication.

    Science.gov (United States)

    Kuroda, Hiroshi; Mukai, Yoshiyuki; Nishiyama, Shuhei; Takeshita, Takayuki; Tateyama, Maki; Takeda, Atsushi; Aoki, Masashi

    2016-12-01

    Thallium intoxication was reported in cases with accidental ingestion, suicide attempt, and criminal adulteration. Reported cases were mostly one-time ingestion, therefore, the clinical course of divisional ingestion has not been fully known. Here, we report a case with two-step thallium intoxication manifesting as tardily accelerated neurologic deterioration. A 16-year-old adolescent was cryptically poisoned with thallium sulfate twice at an interval of 52days. After the first ingestion, neurologic symptoms including visual loss, myalgia, and weakness in legs developed about 40days after the development of acute gastrointestinal symptoms and alopecia. After the second ingestion, neurologic symptoms deteriorated rapidly and severely without gastrointestinal or cutaneous symptoms. Brain magnetic resonance imaging exhibited bilateral optic nerve atrophy. Nerve conduction studies revealed severe peripheral neuropathies in legs. Thallium intoxication was confirmed by an increase in urine thallium egestion. Most of the neurologic manifestations ameliorated in two years, but the visual loss persisted. The source of thallium ingestion was unraveled afterward because a murder suspect in another homicidal assault confessed the forepast adulteration. This discriminating clinical course may be attributable to the cumulative neurotoxicity due to the longer washout-time of thallium in the nervous system than other organs. It is noteworthy that the divisional thallium intoxication may manifest as progressive optic and peripheral neuropathy without gastrointestinal or cutaneous symptoms. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Whole-body counting 1990

    International Nuclear Information System (INIS)

    Strand, P.; Selnaes, T.D.

    1990-01-01

    In order to determine the doses from radiocesium in foods after the Chernobyl accident, four groups were chosen in 1987. Two groups, presumed to have a large consumption of food items with a high radiocesium content, were selected. These were Lapp reindeer breeders from central parts of Norway, and hunters a.o. from the municipality of Oeystre Slidre. Two other groups were randomly selected, one from the municipality of Sel, and one from Oslo. The persons in these two groups were presumed to have an average diet. The fall-out in Sel was fairly large (100 kBq/m 2 ), whereas in Oslo the fall-out level was low (2 kBq/m 2 ). The persons in each group were monitored once a year with whole-body counters, and in connection with these countings dietary surveys were preformed. In 1990 the Sel-group and the Lapps in central parts of Norway were followed. Average whole-body activity in each group is compared to earlier years's results, and an average yearly effective dose equivalent is computed. The Sel-group has an average whole-body activity of 2800 Bq for men, and 690 Bq for women. Compared to earlier years, there is a steady but slow decrease in whole-body activities. Yearly dose is calculated to 0.06 mSv for 1990. The Lapps in central parts of Norway have an average whole-body content of 23800 Bq for men and 13600 Bq for women. This results in an average yearly dose of 0.9 mSv for the individuals in the group. Compared to earlier years, the Lapp group show a decrease in whole-body contents since 1988. This decrease is larger among men than women. 5 refs., 8 figs., 6 tabs

  20. CT dose modulation using automatic exposure control in whole-body PET/CT: effects of scout imaging direction and arm positioning.

    Science.gov (United States)

    Inoue, Yusuke; Nagahara, Kazunori; Kudo, Hiroko; Itoh, Hiroyasu

    2018-01-01

    Automatic exposure control (AEC) modulates tube current and consequently X-ray exposure in CT. We investigated the behavior of AEC systems in whole-body PET/CT. CT images of a whole-body phantom were acquired using AEC on two scanners from different manufactures. The effects of scout imaging direction and arm positioning on dose modulation were evaluated. Image noise was assessed in the chest and upper abdomen. On one scanner, AEC using two scout images in the posteroanterior (PA) and lateral (Lat) directions provided relatively constant image noise along the z-axis with the arms at the sides. Raising the arms increased tube current in the head and neck and decreased it in the body trunk. Image noise increased in the upper abdomen, suggesting excessive reduction in radiation exposure. AEC using the PA scout alone strikingly increased tube current and reduced image noise in the shoulder. Raising the arms did not substantially influence dose modulation and decreased noise in the abdomen. On the other scanner, AEC using the PA scout alone or Lat scout alone resulted in similar dose modulation. Raising the arms increased tube current in the head and neck and decreased it in the trunk. Image noise was higher in the upper abdomen than in the middle and lower chest, and was not influenced by arm positioning. CT dose modulation using AEC may vary greatly depending on scout direction. Raising the arms tended to decrease radiation exposure; however, the effect depends on scout direction and the AEC system.

  1. Risk stratification of patients with hypertension using exercise thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Kane, S.

    1985-01-01

    Hypertension (HT) is an important risk factor in coronary heart disease (CHD) and cardiac morbidity and mortality. This study examined the value of clinical, ECG, exercise (EX) and thallium-201 imaging descriptors that identify patients (pts) with HT at high risk. The 337 pts in the study underwent EX thallium-201 testing for evaluation of chest pain due to suspected or proven CHD. The mean age was 55 years, of whom 79% were still on active anti-HT therapy at the time of the study. The EX thallium scintigrams were evaluated qualitatively and quantitively using circumferential profile analysis. The scans were abnormal in 162 pts (48%) and reversible perfusion defects were present in 106 of the 162 pts (65%). At a folllowup fo up to 74 months, (15 +- 9 mean +- SD), 11 pts had hard cardiac events: 2 died of cardiac causes and 9 had non-fatal acute myocardial infractions. There were no significant differences between those with and without events in age, EX heart rate and double product, EX duration, blood pressure and EX ECG changes. Univariate and multivariate survival analysis (Cox regression model) of important clinical, ECG, EX and thallium variables, identified the presence of abnormal EX images as the only predictor of outcome. (X/sup 2/ = 5.4, p< 0.02). No other variable provided additional prognostic information. Actuarial life table analysis showed that pts with abnormal images had significantly more events than those with normal images (p = 0.008, Mantel-Cox). Thus, EX thallium imaging is useful in risk stratification in pts with HT. The presence of abnormal images identify a subgroup at high risk for future events

  2. Methods of thallium-201 preparation from proton irradiated thallium targets

    International Nuclear Information System (INIS)

    Kozlova, M.D.; Sevast'yanova, A.S.; Malinin, A.B.; Kurenkov, N.V.

    1989-01-01

    Two methods of thallium-201 preparation from Tl-targets irradiated by protons: oxidation-extraction (1) and extraction (2) - are developed. At first radioactive lead is separated from the target material - thallium macroquantities during ∼32 hours, then thallium-201 was separated from residual activity of lead radioisotopes and transformed it into the necessary chemical formula. The 1st and 2nd methods differ from each other by the 1st stage of target retreatment; only extraction was used to separate radioactive lead in the 2nd method. The target was solved in H 2 SO 4 . The 1st method permits to separate thallium-201 with chemical yield not less than 90 %, the 2nd one - higher than 95 %. Volumetric activity of thallium-201 prepared is more than 55 MBq/ml. 5 refs

  3. Mechanisms of thallium-201 accumulation to thyroid gland

    International Nuclear Information System (INIS)

    Kishida, Toshihiro

    1987-01-01

    In this study 91 patients with goiter were scintigraphed for the duration of 84 minutes after intravenous administration of thallium-201 by digital γ camera lined to computer data system. Regions of interest (ROIs) were assigned for thyroid tumor, normal thyroid and back ground, and time-activity curves (TACs) were generated from these ROIs. Na + , K + -ATPase activity of microsome fraction from thyroid tumor and the normal thyroid glands was determined. The first 15 minutes accumulation of each ROI was determined as the early accumulation of thallium-201 for tumor and the normal thyroid glands. Papillary and follicular carcinomas, showing the high accumulation of thallium-201, had high activity of Na + , K + -ATPase. Microfollicular adenomas had high activity of Na + , K + -ATPase and demonstrated intense accumulation of thallium-201. However, colloid adenoma had a similar level of Na + , K + -ATPase activity to that of the normal thyroid glands and did not demonstrate radionuclide accumulation. Consequently, radionuclide accumulation in thallium-201 thyroid scintigraphy was closely correlated to Na + , K + -ATPase activity of thyroid tumor. Thyroid blood flow was measured by hydrogen gas clearance method. Thyroid blood flow of papillary carcinoma was smaller, as compared with normal thyroid blood flow. TAC of papillary carcinoma showed flattening. Thallium-201 accumulation in early image was also found to correspond to thyroid blood flow. From this study we can conclude that mechanisms of thallium-201 accumulation in a thyroid tumor depends on Na + , K + -ATPase activity and thyroid blood flow. Washout of TAC in thallium-201 scintigraphy appears dependent on blood flow of a thyroid nodule. (author)

  4. Reverse redistribution on planar thallium scintigraphy: relationship to resting thallium uptake and long-term outcome

    International Nuclear Information System (INIS)

    Dey, H.M.; Soufer, R.

    1995-01-01

    Reverse redistribution (RR) of thallium-201 has been associated with both acute and healed myocardial infarction, and with recent thrombolysis. The physiologic basis for RR in coronary artery disease (CAD) is unclear but may be related to an admixture of viable and scarred myocardium within the RR segment. We performed thallium reinjection imaging at rest to better characterize RR defects in patients with chronic CAD. We found enhanced uptake of 201 Tl in 52% of RR segments after reinjection, consistent with significant regional viability that was not evident on redistribution images. We then used a logistic multiple regression analysis to determine whether RR alone or in combination with other scintigraphic findings could predict patient outcome. The results showed that severe RR was an independent predictor of patient outcome. We conclude that RR may have prognostic significance in chronic CAD. (orig.)

  5. Hanford whole body counting manual

    International Nuclear Information System (INIS)

    Palmer, H.E.; Rieksts, G.A.; Lynch, T.P.

    1990-06-01

    This document describes the Hanford Whole Body Counting Program as it is administered by Pacific Northwest Laboratory (PNL) in support of the US Department of Energy--Richland Operations Office (DOE-RL) and its Hanford contractors. Program services include providing in vivo measurements of internally deposited radioactivity in Hanford employees (or visitors). Specific chapters of this manual deal with the following subjects: program operational charter, authority, administration, and practices, including interpreting applicable DOE Orders, regulations, and guidance into criteria for in vivo measurement frequency, etc., for the plant-wide whole body counting services; state-of-the-art facilities and equipment used to provide the best in vivo measurement results possible for the approximately 11,000 measurements made annually; procedures for performing the various in vivo measurements at the Whole Body Counter (WBC) and related facilities including whole body counts; operation and maintenance of counting equipment, quality assurance provisions of the program, WBC data processing functions, statistical aspects of in vivo measurements, and whole body counting records and associated guidance documents. 16 refs., 48 figs., 22 tabs

  6. High spatial resolution whole-body MR angiography featuring parallel imaging: initial experience

    International Nuclear Information System (INIS)

    Quick, H.H.; Vogt, F.M.; Madewald, S.; Herborn, C.U.; Bosk, S.; Goehde, S.; Debatin, J.F.; Ladd, M.E.

    2004-01-01

    Materials and methods: whole-body multi-station MRA was performed with a rolling table platform (AngioSURF) on 5 volunteers in two imaging series: 1) standard imaging protocol, 2) modified high-resolution protocol employing PAT using the generalized autocalibrating partially parallel acquisitions (GRAPPA) algorithm with an acceleration factor of 3. For an intra-individual comparison of the two MR examinations, the arterial vasculature was divided into 30 segments. Signal-to-noise ratios (SNR) and contrast-to-noise ratios (CNR) were calculated for all 30 arterial segments of each subject. Vessel segment depiction was qualitatively assessed applying a 5-point scale to each of the segments. Image reconstruction times were recorded for the standard as well as the PAT protocol. Results: compared to the standard protocol, PAT allowed for increased spatial resolution through a 3-fold reduction in mean voxel size for each of the 5 stations. Mean SNR and CNR values over all specified vessel segments decreased by a factor of 1.58 and 1.56, respectively. Despite the reduced SNR and CNR, the depiction of all specified vessel segments increased in PAT images, reflecting the increased spatial resolution. Qualitative comparison of standard and PAT images showed an increase in vessel segment conspicuity with more detailed depiction of intramuscular arterial branches in all volunteers. The time for image data reconstruction of all 5 stations was significantly increased from about 10 minutes to 40 minutes when using the PAT acquisition. (orig.) [de

  7. Quantitative comparison of technetium-99m tetrofosmin and thallium-201 images of the thyroid and abnormal parathyroid glands

    International Nuclear Information System (INIS)

    Giordano, A.; Meduri, G.; Calcagni, M.L.; Marozzi, P.; Ficola, U.; Vaccaro, A.; Rubini, G.; Attard, M.; Li Puma, M.; Ricci, R.; Corsello, S.

    1999-01-01

    The aim of the study was to quantitatively compare the scintigraphic images of the thyroid and abnormal parathyroid glands obtained with technetium-99m tetrofosmin and thallium-201 in patients with hyperparathyroidism. Forty-six patients with hyperparathyroidism underwent 201 Tl (74 MBq), 99m Tc-pertechnetate (74 MBq) and 99m Tc-tetrofosmin (555-740 MBq) scintigraphy in a single session. Image analysis included the computation of the thyroid/background ratio in the whole study population and the parathyroid/background ratio, parathyroid/thyroid ratio and diagnostic sensitivity in 17 patients who underwent parathyroid surgery. The pertechnetate subtraction technique was used. 201 Tl and 99m Tc-tetrofosmin showed a similar thyroid/background ratio (1.79±0.41 and 1.81±0.47, respectively, P=NS); however, 99m Tc-tetrofosmin showed a higher parathyroid/background ratio than 201 Tl (2.06±0.54 vs 1.79± 0.50, P=0.007). Despite the superior quality of 99m Tc-tetrofosmin images, both tracers showed identical sensitivity in detecting enlarged parathyroid glands in patients with primary hyperparathyroidism (89%) and in those with secondary hyperparathyroidism (50%). (orig.)

  8. Utility of thallium-201 and iodine-123 metaiodobenzylguanidine in the scintigraphic detection of neuroendocrine neoplasia

    International Nuclear Information System (INIS)

    Montravers, F.; Coutris, G.; Sarda, L.; Mensch, B.; Talbot, J.N.

    1993-01-01

    In order to determine whether the association of the two markers is able to improve the detection of neuroendocrine lesions, 137 sctinigraphic examinations using MIBG and thallium were performed in 101 patients referred for suspicion or follow-up of neuroendocrine tumours. Thallium chloride was first injected (1 MBq/kg), images being acquired about 20 min after injection; 123 I-MIBG (4 MBq/kg) was then injected and images acquired 5 and 24 h later. In patients with phaeochromocytoma or neuroblastoma, thallium scintigraphy appeared of little help since no tumoural site was discovered by thallium accumulation alone. In contrast, thallium examination seemed of interest in the detection of paraganglioma and MTC, the association of the two radiopharmaceuticals increasing the number of detected sites. (orig./MTG)

  9. The use of thallium-201 scintigraphy in the assessment and management of bone and soft tissue tumours

    International Nuclear Information System (INIS)

    Jong, I.; Schlicht, S.M.; Smith, P.; J Slavin; Powell, G.; Choong, P.F.M.

    2004-01-01

    Introduction: Thallium-201 scintigraphy is routinely performed on all patients presenting to the bone and soft tissue sarcoma service at St. Vincent's Hospital Melbourne. Methods: As part of the multimodality approach to patients presenting to the service, Thallium-201 planar images are obtained at 30 minutes following a resting injection of tracer with delayed planar and where possible SPECT images at 4 hours. Uptake is qualitatively assessed using adjacent muscle uptake at the time of the scan. All thallium-201 scans are read in conjunction with the correlative structural images performed. Results: High grade bone and soft tissue sarcomas typically show significant retention of tracer relative to background activity and adjacent anatomically structures. Benign lesions may show early activity but typically washout on the delayed images. However, some lesions may show marked thallium-201 activity which will be discussed. At our institution the thallium-201 scans are used for assessment of metabolic activity and tumour grade, planning of image guided pre-treatment biopsies and monitoring of treatment response particularly following radiotherapy. Conclusion: Thallium-201 scintigraphy plays a vital role in assessment and management of bone and soft tissue tumours at our institution. (authors)

  10. Whole-body computed tomography

    International Nuclear Information System (INIS)

    Wegener, O.H.

    1992-01-01

    The vast literature on whole-body CT is presented in this bibliography which is published as a self-contained supplement to the monography entitled whole-body CT. For this documentation, the following journals have been scanned back to the year 1980: Journal of Computer Assisted Tomography (JCAT), Fortschritte auf dem Gebiet der Roentgenstrahlen (RoeFo), Radiology, American Journal of Roentgenology (AJR), Der Radiologe, Neuroradiology, and American Journal of Neuroradiology (AJNR). The supplement includes keyword indexes that can be searched for terms indicating body organs, body regions, or certain lesions. The author index offers an additional access to the publication wanted. (orig./MG) [de

  11. Comparison of rest and exercise thallium-201 kinetics in man and implications for quantitation

    International Nuclear Information System (INIS)

    Freeman, M.R.; Kanwar, N.; Armstrong, P.W.

    1989-01-01

    To develop a technique for quantitative analysis of resting thallium scintigrams, an understanding of thallium kinetics at rest is required. This study evaluates in normal man the thallium distribution and washout rates of thallium at rest and compares these findings to similar data obtained during exercise. The thallium half-life in normal resting myocardium is significantly longer than after exercise, 10.2 +/- 1.4 hours versus 3.9 +/- 0.3 hours (P less than .01). Differences in resting thallium half-life exist between the anterior, 45 degrees left anterior oblique (LAO), and 70 degrees LAO views and are 11.4 +/- 1.0, 10.6 +/- 1.0, 8.8 +/- 0.7 hours, respectively (all significantly different from each other by ANOVA, P less than or equal to .01); these differences are related to the imaging sequence. After exercise, the thallium half-life also varies according to imaging sequence, but in the opposite direction; i.e., anterior, 45 degrees LAO, and 70 degrees LAO views are 3.6 +/- 0.1, 3.9 +/- 0.3, 4.2 +/- 0.3 hours, respectively (P less than or equal to .01). Since imaging sequence and time of acquisition at rest and exercise were similar, this finding may be related to earlier maximal uptake of thallium after exercise as compared to rest. There are also significant segmental differences in thallium half-life at rest in the 45 degrees LAO view (9.8 +/- 0.9, septal vs. 11.0 +/- 0.9, posterolateral, P less than .01) and 70 degrees LAO view (8.3 +/- 0.4, anteroseptal vs. 9.2 +/- 0.6, inferior, P less than or equal to .01)

  12. Biphasic thallium 201 SPECT-imaging for the noninvasive diagnosis of myocardial perfusion abnormalities in a child with Kawasaki disease--a case report

    International Nuclear Information System (INIS)

    Hausdorf, G.; Nienaber, C.A.; Spielman, R.P.

    1988-01-01

    The mucocutaneous lymph node syndrome (Kawasaki disease) is of increasing importance for the pediatric cardiologist, for coronary aneurysms with the potential of thrombosis and subsequent stenosis can develop in the course of the disease. The authors report a 2 1/2-year-old female child in whom, fourteen months after the acute phase of Kawasaki disease, myocardial infarction occurred. Biphasic thallium 201 SPECT-imaging using dipyridamole depicted anterior wall ischemia and inferolateral infarction. This case demonstrates that noninvasive vasodilation-redistribution thallium 201 SPECT-imaging has the potential to predict reversible myocardial perfusion defects and myocardial necrosis, even in small infants with Kawasaki disease

  13. Whole body dual X-ray absorptiometry for bone mineral density and body composition using a flat panel detector

    International Nuclear Information System (INIS)

    Dinten, J.M.; Robert-Coutant, C.; Gonon, G.; Bordy, T.

    2003-01-01

    Whole-body dual-energy X-ray absorptiometry (DXA) systems are used for the determination of bone mineral density (BMD) but also for body composition estimates (lean mass and fat mass). The calculation is based on the difference in attenuation of body tissues for a low-energy of about 50 KeV and a high-energy of about 80-100 KeV. The measurement of dual-energy projections allows first to compute to the body composition in the non-bone area, and then to extrapolate the fat / lean ratio of soft tissue into the bone area in order to compute the BMD. Since detectors have limited area, a whole body examination requires a scan of the patient and a reconstruction process in order to build up a large field image from smaller radiographs. This reconstruction process must keep the quantitative value of the radiographs, and avoid any distortion which could be a consequence of the conic acquisition geometry. The cone angle is low (6 at maximum) and the large overlap between radiographs helps to reconstruct an image equivalent with a parallel-beam geometry. Scatter is corrected from the radiographs before reconstruction, as described in a previous paper ('Dual-energy X-rays absorptiometry using a 2D digital radiography detector. Application to bone densitometry', SPIE Medical Imaging 2001, Medical Physics). We have developed an original reconstruction method dedicated to whole-body examinations which will be described. Thanks to the quasi-radiologic quality of the detector, reconstructed images are of very good quality and this makes the measurement of BMD and fat / lean masses easier. (author)

  14. Comparison of the distribution of some thallium chemical species in mice

    International Nuclear Information System (INIS)

    Petitjean, Francoise.

    Scintigraphic images obtained after injection of radioactive thallium show a strong uptake on the kidneys but also on the intestines, which means that quantitative interpretation of the kidney images is troubled by the superposition of these organs. This study is an attempt to find a chemical form of thallium tending less to fix on the intestinal mucous membrane but keeping its affinity for the medullary zone of the kidney. Various agents forming stable complexes with the metal were investigated. Radiothallium is generally used in the chemical form of monovalent thallium chloride. However the degree of oxidation I is unsuitable for stable complex formation and therefore trivalent thallium was also used. Separation of Tl(I) and Tl(III) with ion exchange resin showed the instability of trivalent chloride at low concentration and when the solution is more than 2 hours old the trivalent thallium solutions injected are 10 -5 M. Calculation of the complex formation constants revealed the absence or formation of monovalent thallium complexes. In all monovalent thallium solutions (with or without carrier, with EDTA or HEDTA) the predominant chemical species is Tl + . In the case of trivalent thallium three solutions with carrier were used; the predominant species is TlCl 6 3- when the solution contains Cl - and EDTA and TlEDTA when Cl - , NO 3 - and EDTA are present. These solutions were injected intraveinously into mice in order to study the radiothallium distribution in the kidney and intestine by comparison with that of TlCl while the chemical species varied from one preparation to another no great difference in the radiothallium distribution was observed [fr

  15. Whole-body MR imaging in psoriatic arthritis: Additional value for therapeutic decision making

    International Nuclear Information System (INIS)

    Weckbach, Sabine; Schewe, Stefan; Michaely, Henrik J.; Steffinger, Denise; Reiser, Maximilian F.; Glaser, Christian

    2011-01-01

    Purpose: In psoriatic arthritis (PsA) multiple locations may show inflammatory changes not always readily accessible to clinical exam. Often, clinical exam is inconclusive and the decision to initiate or adapt therapy is difficult. Whole body (WB)-MRI may help in this situation by providing a comprehensive overview of affected areas/joints. The purpose of this study was to make a proof of concept whether WB-MRI in psoriatic arthritis is feasible and can provide additional information compared to clinical examination alone with regard to therapeutic decision making in patients with PsA and inconclusive clinical situation. Materials and Methods: 30 patients with PsA and diffuse musculoskeletal pain were examined. A WB-MRI protocol was implemented on a 1.5 Tesla scanner using coronal and sagittal STIR- (TR: 5800, TE: 54, matrix 384 2 pixels, FOV 400 mm) and pre- and steady-state-post-Gadolinium-VIBE sequences (TR: 9.82, TE: 4.53, matrix 384 x 307 pixels, FOV: 400 mm). MRI was evaluated for image quality and inflammatory findings by two readers in consensus and compared to clinical exam. Results: The WB-MR-exam was well tolerated by all patients. Image quality was rated good to excellent in 26 of 30 patients (86.6%). WB-MRI detected significantly (p < 0.001) more areas of synovitis/enthesitis than clinical exam except for the hands and feet. MRI was able to detect unknown destructive bony changes in 10 patients (53%). In 22 patients (73.3%) the therapy regimen was modified, in 18 patients (62%) TNF-alpha-inhibitors were started. Conclusion: Whole-body MRI (WB-MRI) may be integrated in the diagnostic work-up of patients with psoriatic arthropathy facilitating individual adaptation of therapeutic strategy.

  16. Impact of body habitus on quantitative and qualitative image quality in whole-body FDG-PET

    Energy Technology Data Exchange (ETDEWEB)

    Tatsumi, Mitsuaki; Clark, Paul A.; Nakamoto, Yuji; Wahl, Richard L. [Division of Nuclear Medicine, Department of Radiology, The Johns Hopkins Medical Institutions, 601 N. Caroline St., Rm 3223, Baltimore, MD 21287-0817 (United States)

    2003-01-01

    Obtaining consistent high image quality is desirable for clinical positron emission tomography (PET). Body morphology may impact image quality. The purpose of this study was to define the average and the range of body sizes in patients undergoing tumor PET studies in our center and to determine how the body habitus affects the statistical and visual quality of PET images. Height, weight, body surface area (BSA), and body mass index (BMI) were determined in 101 male and 101 female patients (group 1) referred for clinical PET. The summed total counts from three consecutive transaxial slices on non-attenuation-corrected (NAC) 2D fluorine-18 fluorodeoxyglucose (FDG) PET images, which included the largest liver section and no lesions, were determined and compared with body morphology and injected doses (ID) in a representative group of 30 male and 30 female patients (group 2) spanning a range of body morphologies. The visual quality of images was also evaluated using a scoring system by three readers. The average height, weight, and BSA were greater in male than in female patients, but the average BMI was not different between them in group 1. The largest value of weight or BMI was more than four times the smallest value in female patients. The total true counts were best correlated with ID/weight (mCi/kg) in group 2 (r=0.929, P<0.0001). Intermediate to high total counts (930,000 or more) corresponded to ID/weight of 0.22 or higher. The average visual score was positively correlated with the total counts ({rho}=0.63, P<0.0001) and with ID/weight ({rho}=0.68, P<0.0001) on NAC images. The image quality in 22 (84.6%) of 26 patients with intermediate to high total counts was adequate to good, whereas that in 21 (61.8%) of 34 patients with lower total counts was suboptimal. A wide variety of body morphologies was observed in patients referred for clinical FDG-PET tumor studies in our center. The total counts and average image visual score were negatively correlated with

  17. Whole spine MRI in the assessment of acute vertebral body trauma

    International Nuclear Information System (INIS)

    Green, R.A.R.; Saifuddin, A.

    2004-01-01

    To determine the incidence and types of multilevel vertebral body injury in association with acute spinal trauma as assessed by whole spine MRI. All acute admissions to a regional spinal injury unit had whole spine MRI carried out, to detect occult vertebral body injury. Two radiologists assessed 127 cases prospectively, over a period of 3 years. All cases had T2-weighted sagittal imaging of the whole spine (where possible using a T2-weighted fat-suppressed sequence), with T1-weighted imaging in both sagittal and axial planes covering the primary injury. The incidence of secondary injury (defined as either bone bruising, wedge compression fracture or burst fracture) was determined and defined by type, site and relationship to the primary injury. Seventy-seven per cent of cases had a secondary injury level. Of these, bone bruising was the commonest but often occurred in combination with secondary wedge compression fracture or burst fracture. MRI detected 27 non-contiguous wedge compression fractures and 16 non-contiguous burst fractures, giving an incidence of secondary level, non-contiguous fracture of approximately 34%. A higher frequency of secondary vertebral body injury may be defined by MRI than has been described in previous studies based on radiographic evaluation of the whole spine. Whole spine MRI in assessment for occult vertebral body fracture enables increased confidence in the conservative or surgical management of patients with severe spinal injury. (orig.)

  18. Prognostic value of dipyridamole thallium scintigraphy for evaluation of ischemic heart disease

    International Nuclear Information System (INIS)

    Hendel, R.C.; Layden, J.J.; Leppo, J.A.

    1990-01-01

    Exercise testing alone or in combination with thallium scintigraphy has significant prognostic value. In contrast, dipyridamole thallium imaging is not dependent on patients achieving adequate levels of exercise, but no long-term prognostic studies have been reported. Accordingly, imaging results of 516 consecutive patients referred for dipyridamole thallium studies were correlated with subsequent cardiac events, death (n = 23) and myocardial infarction (n = 43) over a mean follow-up period of 21 months. Patients with a history of congestive heart failure, prior myocardial infarction, diabetes mellitus or abnormal scans were significantly more likely to have a cardiac event (p less than 0.03). With use of logistic regression analysis, an abnormal scan was an independent and significant predictor of subsequent myocardial infarction or cardiac death and increased the relative risk of any event more than threefold. The presence of redistribution on thallium scanning further increased the risk of a cardiac event. Survival analysis demonstrated a significant difference between patients with an abnormal or normal thallium scan over a 30 month period. In conclusion, dipyridamole thallium scintigraphy demonstrates prognostic value in a large unselected population and may be an adequate clinical alternative to physiologic exercise testing in the evaluation of coronary heart disease

  19. [Efficiency of hemoperfusion on clearing thallium based on atomic absorption spectrometry].

    Science.gov (United States)

    Tian, Tian; Wang, Yongan; Nie, Zhiyong; Wang, Jiao; Peng, Xiaobo; Yuan, Ye; Li, Wanhua; Qiu, Zewu; Xue, Yanping; Xiong, Yiru

    2015-04-01

    To determine thallium in whole blood by atomic absorption detection method, and to investigate the eliminating effect of hemoperfusion (HP) for thallium in blood. The blood of Beagle dogs which had not exposed to thallium before were obtained for preparation of thallium nitrate ( TlNO3 )-containing solution in three concentrations according to the conversion formula based on animal weight and volume of blood. HP was performed in the simulated in vivo environment. The content of TlNO3 in blood of the next group was determined on the amount of TlNO3 for the last HP of the former dose group. Thallium quantity in different samples was measured with atomic absorption spectrometer blood samples before and after HP. Finally, the thallium concentration in blood was analyzed statistically. Thallium concentrations showed a good linear relationship in the range of 0-200 μg/L (r = 0.998 4). The intra-day precision (RSD) was lower than 4.913%, the intra-day recovery rate was 96.2%-111.9%; the inter-day precision (RSD) was lower than 7.502%, the inter-day recovery rate was 89.6%-105.2%. The concentration of thallium in blood was significantly reduced after HP per time in high, middle, and low dose groups [(453.43 ± 27.80) mg/L to (56.09 ± 14.44) mg/L in high dose group, F = 8.820, P = 0.003; (64.51 ± 13.60) mg/L to (3.19 ± 0.23) mg/L in middle dose group, F = 36.312, P = 0.000; (5.40 ± 0.98) mg/L to (0.38 ± 0.25) mg/L in low dose group, F = 46.240, P = 0.000 ]. The adsorption rate of four times of HP in high, middle and low dose group were (87.63 ± 2.48 )%, (95.06 ± 1.54 )% and (92.76 ± 4.87)%, respectively, without significant difference (F = 4.231, P = 0.070). The method for measuring thallium was established, and it shows a very stable, simple, sensitive for determination of thallium. HP can effectively remove thallium from blood. Thallium concentration can be reduced by 90% after four times of HP. HP is also effective even when thallium concentration is not high.

  20. Image quality assessment of LaBr3-based whole-body 3D PET scanners: a Monte Carlo evaluation

    International Nuclear Information System (INIS)

    Surti, S; Karp, J S; Muehllehner, G

    2004-01-01

    The main thrust for this work is the investigation and design of a whole-body PET scanner based on new lanthanum bromide scintillators. We use Monte Carlo simulations to generate data for a 3D PET scanner based on LaBr 3 detectors, and to assess the count-rate capability and the reconstructed image quality of phantoms with hot and cold spheres using contrast and noise parameters. Previously we have shown that LaBr 3 has very high light output, excellent energy resolution and fast timing properties which can lead to the design of a time-of-flight (TOF) whole-body PET camera. The data presented here illustrate the performance of LaBr 3 without the additional benefit of TOF information, although our intention is to develop a scanner with TOF measurement capability. The only drawbacks of LaBr 3 are the lower stopping power and photo-fraction which affect both sensitivity and spatial resolution. However, in 3D PET imaging where energy resolution is very important for reducing scattered coincidences in the reconstructed image, the image quality attained in a non-TOF LaBr 3 scanner can potentially equal or surpass that achieved with other high sensitivity scanners. Our results show that there is a gain in NEC arising from the reduced scatter and random fractions in a LaBr 3 scanner. The reconstructed image resolution is slightly worse than a high-Z scintillator, but at increased count-rates, reduced pulse pileup leads to an image resolution similar to that of LSO. Image quality simulations predict reduced contrast for small hot spheres compared to an LSO scanner, but improved noise characteristics at similar clinical activity levels

  1. Role of exercise thallium-201 myocardial perfusion scintigraphy in predicting prognosis in suspected coronary artery disease

    International Nuclear Information System (INIS)

    Koss, J.H.; Kobren, S.M.; Grunwald, A.M.; Bodenheimer, M.M.

    1987-01-01

    While exercise thallium imaging has improved sensitivity and specificity for detection of coronary artery disease (CAD), its predictive value for morbid cardiac events is unclear. Of 532 consecutive patients who underwent exercise thallium imaging, follow-up was complete in 515 (97%) after an average of 36 months (range 31 to 48). Two hundred six patients had an abnormal exercise thallium response and 309 had a normal response. Twenty morbid cardiac events occurred (13 deaths and 7 acute myocardial infarctions [AMI]). Of the 13 patients who died, 12 had abnormal thallium results. Overall, 5.8% of the patients with abnormal thallium results died, in contrast to 0.3% of patients with normal results. Of the 7 patients who had a nonfatal AMI, 3 had abnormal exercise thallium results. Moreover, similar proportions of patients (1.4% and 1.3%) with normal and abnormal exercise thallium results had nonfatal AMI. Presence or absence of pathologic Q waves and inclusion of exercise electrocardiographic results did not significantly alter the results. Thus, although a normal exercise thallium response significantly reduces the likelihood of cardiovascular death, its predictive value for nonfatal AMI is limited. Moreover, the relatively low event rate for patients with a positive exercise thallium response further limits its prognostic value

  2. Thallium-201 exercise myocardial imaging to evaluate myocardial perfusion after coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Hirzel, H.O.; Nuesch, K.; Sialer, G.; Horst, W.; Krayenbuehl, H.P.

    1980-01-01

    To assess the usefulness of thallium-201 exercise scintigraphy in evaluating myocardial perfusion after coronary artery bypass surgery, imaging was performed after submaximal bicycle ergometry and at rest in 54 patients before and within 24 +- 10 (SD) weeks after operation. Scintigraphy identified 8 out of 20 patients who were symptom free after operation and showed normal exercise electrocardiograms as still having exercise-induced ischaemia and thus as having not truly benefited from the surgical intervention. In contrast, improvement in perfusion was documented in 17 out of 31 patients despite further complaints of chest pain and persistence of a pathological exercise electrocardiogram in 6 of them. Bypass graft patency rate paralleled the scintigraphic findings in the 35 patients who were restudied arteriographically. It was concluded that thallium-201 exercise scintigraphy is a useful technique to document changes in regional perfusion after surgery and is definitely superior to the clinical evaluation of patients including the exercise electrocardiogram. (author)

  3. Analysis of the degree of pulmonary thallium washout after exercise in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Levy, R.; Rozanski, A.; Berman, D.S.; Garcia, E.; Van Train, K.; Maddahi, J.; Swan, H.J.

    1983-01-01

    An abnormal increase in pulmonary thallium activity may be visualized on post-stress thallium images in patients with coronary artery disease. Because this increased pulmonary thallium activity usually disappears by the time of redistribution imaging, this study was designed to assess whether measurement of the degree of pulmonary thallium washout between stress and redistribution might improve the detection of increased pulmonary thallium activity in patients with coronary artery disease. Quantitative analysis revealed abnormal (that is, greater than 2 standard deviations of normal values) pulmonary thallium washouts in 59 (64%) of 92 patients with coronary artery disease, but in only 2 (25%) of 8 subjects with angiographically normal arteries (p less than 0.06). By comparison, the visual analysis of pulmonary thallium washout and use of initial pulmonary to myocardial thallium ratio were significantly (p less than 0.05) less sensitive in detecting abnormality in patients with coronary artery disease. Abnormal pulmonary thallium washout was related to both the anatomic extent and functional severity of disease: it occurred with greatest frequency in patients with multivessel disease and in those with exercise-induced left ventricular dysfunction (p less than 0.005). When added to the quantitative analysis of myocardial scintigraphy, the analysis of pulmonary thallium washout increased the detection of coronary artery disease from 84 to 93% (p less than 0.05), but the sample size was too small to assess specificity

  4. Influence of peak exercise heart rate on normal thallium-201 myocardial clearance

    International Nuclear Information System (INIS)

    Kaul, S.; Chesler, D.A.; Pohost, G.M.; Strauss, H.W.; Okada, R.D.; Boucher, C.A.

    1986-01-01

    Measurement of myocardial clearance rates between initial and delayed images is a major justification for adding computer quantification to the interpretation of exercise 201 TI images. To clarify the range of normal thallium clearance and its relationship to the level of exercise achieved, exercise thallium images in 89 normal subjects were analyzed: 45 asymptomatic subjects with less than 1% probability of coronary artery disease (CAD) (Group I), and 44 patients with chest pain found to have no significant CAD on angiography (Group II). Mean initial regional thallium uptake was similar in the two groups, but myocardial thallium clearance (mean +/- 1 s.d.) was slower in Group II, expressed as a longer half-life in the myocardium (8.2 +/- 7.6 hr compared with 3.4 +/- 0.7 hr p less than 0.001). Analysis of variance using ten clinical and exercise variables as covariates showed that the slower clearance in Group II was related to a lower peak exercise heart rate (HR) (154 +/- 27 compared with 183 +/- 11, respectively, p less than 0.001). By linear regression analysis, a decrease in peak HR of 1 beat/min was associated with a slower thallium clearance (longer half-life) of 0.05 hr. Using this formula, the clearance value in each patient was then corrected for peak exercise heart rate by decreasing measured clearance by 0.05 hr multiplied by the amount peak exercise heart rate which was below 183 (the mean value in Group I). There were no differences in the corrected clearance between the two groups. We conclude that thallium myocardial clearance after exercise is related in part to factors other than the presence of CAD, being slower when peak exercise HR is lower. Therefore, thallium clearance rates alone uncorrected for peak exercise heart rate should be used with caution when diagnosing CAD

  5. Detection of viability by percent thallium uptake with conventional thallium scintigraphy

    International Nuclear Information System (INIS)

    Imai, Kamon; Araki, Yasushi; Horiuchi, Kou-ichi; Yumikura, Sei; Saito, Satoshi; Ozawa, Yukio; Kan-matsuse, Katsuo; Hagiwara, Kazuo.

    1994-01-01

    Thallium myocardial scintigraphy (TMS) is used for diagnosis of viability in infarcted myocardium before coronary revascularization. Underestimation of viability by TMS has been reported by many investigators. To evaluate viability precisely, thallium re-injection method or 24 hour delayed imaging is performed. However, these techniques are not convenient and are difficult to perform in clinical practice. Percent T1-uptake method was developed for predicting myocardial viability. To evaluate usefulness of this method, TMS was performed before and after PTCA in 23 patients with myocardial infarction. Left ventricle was divided into 3 layers, then each layer was divided into 4 segments (12 segments in total). Forth three segments showed recovery of perfusion on TMS after PTCA. Viability in infarcted myocardium is predicted by 1) redistribution (RD), 2) %T1-uptake≥45% on the image immediately after exercise (TE), and 3) %T1-uptake≥45% on delayed image (TD). Sensitivity was RD: 60%, TE: 90% and TD: 95% (p<0.001 vs. RD). Specificity was RD: 74%, TE: 68%, and TD: 60% (NS). Predictive accuracy (PA) was RD: 69%, TE: 77%, TD: 73% (NS). Compared with RD, %T1-uptake, either TE or TD, increased sensitivity with slightly improved PA, but decreased specificity slightly. Therefore %T1-uptake would be a sensitive and useful predictor to find patients who are most likely to benefit from re-vascularization. (author)

  6. Late reversibility of tomographic myocardial thallium-201 defects: an accurate marker of myocardial viability

    International Nuclear Information System (INIS)

    Kiat, H.; Berman, D.S.; Maddahi, J.; De Yang, L.; Van Train, K.; Rozanski, A.; Friedman, J.

    1988-01-01

    Twenty-one patients were studied who underwent thallium-201 stress-redistribution single photon emission computed tomography (SPECT) both before and after coronary artery bypass grafting (n = 15) or transluminal coronary angioplasty (n = 6). All patients underwent thallium imaging 15 min, 4 h and late (18 to 72 h) after stress as part of the preintervention thallium-201 scintigram. In a total of 201 tomographic myocardial segments with definite post-stress thallium-201 perfusion defects in which the relevant coronary arteries were subsequently successfully reperfused, the 4 h redistribution images did not predict the postintervention scintigraphic improvement: 67 (85%) of the 79 4 h reversible as well as 88 (72%) of the 122 4 h nonreversible segments improved (p = NS). The 18 to 72 h late redistribution images effectively subcategorized the 4 h nonreversible segments with respect to postintervention scintigraphic improvement: 70 (95%) of the 74 late reversible segments improved after intervention, whereas only 18 (37%) of the 48 late nonreversible segments improved (p less than 0.0001). The frequency of late reversible defects and the frequency of postrevascularization improvement of late nonreversible defects are probably overestimated by this study because of referral biases. The cardiac counts and target to background ratios from late redistribution studies resulted in satisfactory cardiac images for visual interpretation. For optimal assessment of the extent of viable myocardium by thallium-201 scintigraphic studies, late redistribution imaging should be performed when nonreversible defects are observed on 4 h redistribution images

  7. Comparison of thallium-201 and gallium-67 scintigraphy in soft tissue and bone marrow multiple myeloma: a case report

    International Nuclear Information System (INIS)

    Roach, P.J.; Arthur, C.K.

    1997-01-01

    A 68 year old female was referred for assessment of multiple myeloma. A large myelomatous infiltrate involving the left triceps muscle showed avid uptake on both thallium-201 and gallium-67 scintigraphy. Following radiotherapy, imaging with both radiopharmaceuticals showed resolution of disease; however, tumour recurrence in the bone marrow was seen only on thallium-201 imaging. This observation suggests that while soft-tissue myleoma shows similar appearances on thallium-201 and gallium-67 scintigraphy, both at baseline and following therapy, gallium-67 may not demonstrate bone marrow infiltration which is visualized on thallium-201 imaging. Therefore, thallium-201 appears to be superior to gallium-67 in evaluation of patients with multiple myeloma when soft tissues and bone marrow are involved. 17 refs., 3 figs

  8. Whole body sodium MRI at 3T using an asymmetric birdcage resonator and short echo time sequence: first images of a male volunteer

    Science.gov (United States)

    Wetterling, Friedrich; Corteville, Dominique M.; Kalayciyan, Raffi; Rennings, Andreas; Konstandin, Simon; Nagel, Armin M.; Stark, Helmut; Schad, Lothar R.

    2012-07-01

    Sodium magnetic resonance imaging (23Na MRI) is a non-invasive technique which allows spatial resolution of the tissue sodium concentration (TSC) in the human body. TSC measurements could potentially serve to monitor early treatment success of chemotherapy on patients who suffer from whole body metastases. Yet, the acquisition of whole body sodium (23Na) images has been hampered so far by the lack of large resonators and the extremely low signal-to-noise ratio (SNR) achieved with existing resonator systems. In this study, a 23Na resonator was constructed for whole body 23Na MRI at 3T comprising of a 16-leg, asymmetrical birdcage structure with 34 cm height, 47.5 cm width and 50 cm length. The resonator was driven in quadrature mode and could be used either as a transceiver resonator or, since active decoupling was included, as a transmit-only resonator in conjunction with a receive-only (RO) surface resonator. The relative B1-field profile was simulated and measured on phantoms, and 3D whole body 23Na MRI data of a healthy male volunteer were acquired in five segments with a nominal isotropic resolution of (6 × 6 × 6) mm3 and a 10 min acquisition time per scan. The measured SNR values in the 23Na-MR images varied from 9 ± 2 in calf muscle, 15 ± 2 in brain tissue, 23 ± 2 in the prostate and up to 42 ± 5 in the vertebral discs. Arms, legs, knees and hands could also be resolved with applied resonator and short time-to-echo (TE) (0.5 ms) radial sequence. Up to fivefold SNR improvement was achieved through combining the birdcage with local RO surface coil. In conclusion, 23Na MRI of the entire human body provides sub-cm spatial resolution, which allows resolution of all major human body parts with a scan time of less than 60 min.

  9. Myocardial rest iodine-123-β-methyl-iodophenyl-pentadecanoic acid scintigraphy compared with dipyridamole stress thallium-201 scintigraphy in unstable angina

    International Nuclear Information System (INIS)

    Misumi, Ikuo; Kimura, Yoshihiro; Hokamura, Youichi; Yamabe, Hiroshige; Ueno, Kazuhiro

    1998-01-01

    Twelve patients with stable angina and 12 patients with unstable angina underwent rest iodine-123-β-methyl-iodophenyl-pentadecanoic acid (BMIPP), dipyridamole stress thallium scintigraphy and delayed thallium scintigraphy. In stable angina, sensitivity for detecting ischemic segments was higher in dipyridamole thallium (74%) than rest BMIPP (48%) images (p<0.05), but there was no significant difference between the 2 images in unstable angina. In unstable angina, the incidence of segments with higher defect scores on BMIPP images than on delayed thallium images and the opposite pattern was 27 and 5 (p<0.01). In stable angina, there was no difference. The mean defect score on BMIPP (6.3±5.6) was higher than that on delayed thallium scintigraphy (2.9±2.7) and it was almost the same as on the initial dipyridamole stress test (6.5±5.2). In conclusion, BMIPP scintigraphy is safer and may be as useful in detecting myocardial ischemia in patients with unstable angina as thallium scintigraphy. (author)

  10. Thallium-201 scintigraphy for bone and soft tissue tumors

    Energy Technology Data Exchange (ETDEWEB)

    Tokuumi, Yuji; Tsuchiya, Hiroyuki; Sunayama, Chiaki; Matsuda, Eizo; Asada, Naohiro; Taki, Junichi; Sumiya, Hisashi; Miyauchi, Tsutomu; Tomita, Katsuro [Kanazawa Univ. (Japan). School of Medicine

    1995-05-01

    This study was undertaken to assess the usefulness of thallium-201 scintigraphy in bone and soft tissue tumors. Pre-therapy scintigraphy was undertaken in a total of 136 patients with histologically confirmed diagnosis, consisting of 74 with malignant bone and soft tissue tumors, 39 with benign ones, 12 with diseases analogous to tumors, and 11 others. Thallium activity was graded on a scale of 0-4: 0=background activity, 1=equivocal activity, 2=definitive activity, but less than myocardium, 3=definite activity equal to myocardium, and 4=activity greater than myocardium. In the group of malignant tumors, thallium-201 uptake was found in 80%, although it was low for chondrosarcoma (2/8) and malignant Schwannoma (one/3). The group of benign tumors, however, showed it in only 41%, being restricted to those with giant cell tumors, chondroblastoma, fibromatosis, and osteoid osteoma. Thallium-201 uptake was also found in all 8 patients with metastatic tumors. In 23 patients undergoing thallium imaging before and after chemotherapy, scintigraphic findings revealed a high correlation with histopathological findings. Thus, thallium-201 scintigraphy may be potentially used to distinguish malignant from benign bone and soft tissue tumors, except for a few histopathological cases, as well as to determine loco-regional metastases and response to chemotherapy. (N.K.).

  11. Estimating {sup 131}I biokinetics and radiation doses to the red marrow and whole body in thyroid cancer patients: probe detection versus image quantification

    Energy Technology Data Exchange (ETDEWEB)

    Willegaignon, Jose; Pelissoni, Rogerio Alexandre; Lima, Beatriz Christine de Godoy Diniz; Coura-Filho, George Barberio; Queiroz, Marcelo Araujo, E-mail: j.willegaignon@gmail.com [Instituto do Cancer do Estado de Sao Paulo Octavio Frias de Oliveira (ICESP), Sao Paulo, SP (Brazil); Sapienza, Marcelo Tatit; Buchpiguel, Carlos Alberto [Universidade de Sao Paulo (FM/USP), Sao Paulo, SP (Brazil). Faculdade de Medicina. Departamento de Radiologia

    2016-05-15

    Objective: to compare the probe detection method with the image quantification method when estimating {sup 131}I biokinetics and radiation doses to the red marrow and whole body in the treatment of thyroid cancer patients. Materials and methods: fourteen patients with metastatic thyroid cancer, without metastatic bone involvement, were submitted to therapy planning in order to tailor the therapeutic amount of {sup 131}I to each individual. Whole-body scans and probe measurements were performed at 4, 24, 48, 72, and 96 h after {sup 131}I administration in order to estimate the effective half-life (T{sub eff}) and residence time of {sup 131}I in the body. Results: the mean values for T{sub eff} and residence time, respectively, were 19 ± 9 h and 28 ± 12 h for probe detection, compared with 20 ± 13 h and 29 ± 18 h for image quantification. The average dose to the red marrow and whole body, respectively, was 0.061 ± 0.041 mGy/MBq and 0.073 ± 0.040 mGy/MBq for probe detection, compared with 0.066 ± 0.055 mGy/MBq and 0.078 ± 0.056 mGy/MBq for image quantification. Statistical analysis proved that there were no significant differences between the two methods for estimating the T{sub eff} (p = 0.801), residence time (p = 0.801), dose to the red marrow (p = 0.708), and dose to the whole body (p = 0.811), even when we considered an optimized approach for calculating doses only at 4 h and 96 h after {sup 131}I administration (p > 0.914). Conclusion: there is full agreement as to the feasibility of using probe detection and image quantification when estimating {sup 131}I biokinetics and red-marrow/whole-body doses. However, because the probe detection method is ineffective in identifying tumor sites and critical organs during radionuclide therapy and therefore liable to skew adjustment of the amount of {sup 131}I to be administered to patients under such therapy, it should be used with caution. (author)

  12. Monitoring scanner calibration using the image-derived arterial blood SUV in whole-body FDG-PET.

    Science.gov (United States)

    Maus, Jens; Hofheinz, Frank; Apostolova, Ivayla; Kreissl, Michael C; Kotzerke, Jörg; van den Hoff, Jörg

    2018-05-15

    The current de facto standard for quantification of tumor metabolism in oncological whole-body PET is the standardized uptake value (SUV) approach. SUV determination requires accurate scanner calibration. Residual inaccuracies of the calibration lead to biased SUV values. Especially, this can adversely affect multicenter trials where it is difficult to ensure reliable cross-calibration across participating sites. The goal of the present work was the evaluation of a new method for monitoring scanner calibration utilizing the image-derived arterial blood SUV (BSUV) averaged over a sufficiently large number of whole-body FDG-PET investigations. Data of 681 patients from three sites which underwent routine 18 F-FDG PET/CT or PET/MR were retrospectively analyzed. BSUV was determined in the descending aorta using a three-dimensional ROI concentric to the aorta's centerline. The ROI was delineated in the CT or MRI images and transferred to the PET images. A minimum ROI volume of 5 mL and a concentric safety margin to the aortic wall was observed. Mean BSUV, standard deviation (SD), and standard error of the mean (SE) were computed for three groups of patients at each site, investigated 2 years apart, respectively, with group sizes between 53 and 100 patients. Differences of mean BSUV between the individual groups and sites were determined. SD (SE) of BSUV in the different groups ranged from 14.3 to 20.7% (1.7 to 2.8%). Differences of mean BSUV between intra-site groups were small (1.1-6.3%). Only one out of nine of these differences reached statistical significance. Inter-site differences were distinctly larger (12.6-25.1%) and highly significant (PPET investigations is a viable approach for ensuring consistent scanner calibration over time and across different sites. We propose this approach as a quality control and cross-calibration tool augmenting established phantom-based procedures.

  13. Influence of Desorption Conditions on Analyte Sensitivity and Internal Energy in Discrete Tissue or Whole Body Imaging by IR-MALDESI

    Science.gov (United States)

    Rosen, Elias P.; Bokhart, Mark T.; Ghashghaei, H. Troy; Muddiman, David C.

    2015-06-01

    Analyte signal in a laser desorption/postionization scheme such as infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is strongly coupled to the degree of overlap between the desorbed plume of neutral material from a sample and an orthogonal electrospray. In this work, we systematically examine the effect of desorption conditions on IR-MALDESI response to pharmaceutical drugs and endogenous lipids in biological tissue using a design of experiments approach. Optimized desorption conditions have then been used to conduct an untargeted lipidomic analysis of whole body sagittal sections of neonate mouse. IR-MALDESI response to a wide range of lipid classes has been demonstrated, with enhanced lipid coverage received by varying the laser wavelength used for mass spectrometry imaging (MSI). Targeted MS2 imaging (MS2I) of an analyte, cocaine, deposited beneath whole body sections allowed determination of tissue-specific ion response factors, and CID fragments of cocaine were monitored to comment on wavelength-dependent internal energy deposition based on the "survival yield" method.

  14. [Thallium content in adults older than 45 ages at Hezhang County of Guizhou Province].

    Science.gov (United States)

    Zhang, Wenli; Yao, Dancheng; Feng, Jiali; Zeng, Dong; Fan, Di; Shang, Qi

    2011-05-01

    To investigate the feature of Thallium content in adults of heavy metal contaminated district due to mining of Hezhang County, Guizhou Province. METHODS The subjects older than 45 ages were randomly recruited from the mineralized district (Magu village) and no-mineralized district (Salaxi viillage) , urine of villagers were collected and thallium content in urine were detected with ICP-MS. The average thallium contents in urine of Magu villagers were higner than those of Salaxi villagers,The urinary thallium contents of female were higner than those of male. The urinary thallium contents of residents in two districts were mostly under the upper limit of exposure in human bodies. There was no villager suffered from chronic poisoning of thallium in the two observing districts, the 95% upper limits of urinary thallium content for nonoccupational women older than 45 ages in Magu village was 8 microg/gCr and those for other nonoccupational subjects older than 45 ages was 5 microg/gCr.

  15. From whole-body sections down to cellular level, multiscale imaging of phospholipids by MALDI mass spectrometry.

    Science.gov (United States)

    Chaurand, Pierre; Cornett, Dale S; Angel, Peggi M; Caprioli, Richard M

    2011-02-01

    Significant progress in instrumentation and sample preparation approaches have recently expanded the potential of MALDI imaging mass spectrometry to the analysis of phospholipids and other endogenous metabolites naturally occurring in tissue specimens. Here we explore some of the requirements necessary for the successful analysis and imaging of phospholipids from thin tissue sections of various dimensions by MALDI time-of-flight mass spectrometry. We address methodology issues relative to the imaging of whole-body sections such as those cut from model laboratory animals, sections of intermediate dimensions typically prepared from individual organs, as well as the requirements for imaging areas of interests from these sections at a cellular scale spatial resolution. We also review existing limitations of MALDI imaging MS technology relative to compound identification. Finally, we conclude with a perspective on important issues relative to data exploitation and management that need to be solved to maximize biological understanding of the tissue specimen investigated.

  16. Detection of bone metastasis of prostate cancer. Comparison of whole-body MRI and bone scintigraphy

    International Nuclear Information System (INIS)

    Ketelsen, D.; Roethke, M.; Aschoff, P.; Lichy, M.P.; Claussen, C.D.; Schlemmer, H.P.; Merseburger, A.S.; Reimold, M.

    2008-01-01

    Purpose: prostate cancer continues to be the third leading cancer-related mortality of western men. Early diagnosis of bone metastasis is important for the therapy regime and for assessing the prognosis. The standard method is bone scintigraphy. Whole-body MRI proved to be more sensitive for early detection of skeletal metastasis. However, studies of homogenous tumor entities are not available. The aim of the study was to compare bone scintigraphy and whole-body MRI regarding the detection of bone metastasis of prostate cancer. Materials and methods: 14 patients with histologically confirmed prostate cancer and a bone scintigraphy as well as whole-body MRI within one month were included. The mean age was 68 years. Scintigraphy was performed using the planar whole-body technique (ventral and dorsal projections). Suspect areas were enlarged. Whole-body MRI was conducted using native T1w and STIR sequences in the coronary plane of the whole body, sagittal imaging of spine and breath-hold STIR and T1w-Flash-2D sequences of ribs and chest. Bone scintigraphy and whole-body MRI were evaluated retrospectively by experienced radiologists in a consensus reading on a lesion-based level. Results: whole-body MRI detected significantly more bone metastasis (p = 0.024). 96.4% of the demonstrated skeletal metastases in bone scintigraphy were founded in whole-body MRI while only 58.6% of the depicted metastases in MRI were able to be located in scintigraphy. There was no significant difference regarding bone metastasis greater than one centimeter (p = 0.082) in contrast to metastasis less than one centimeter (p = 0.035). Small osteoblastic metastases showed a considerably higher contrast in T1w sequences than in STIR imaging. Further advantages of whole-body MRI were additional information about extra-osseous tumor infiltration and their complications, for example stenosis of spinal canal or vertebral body fractures, found in 42.9% of patients. (orig.)

  17. Intracoronary thallium-201 assessment of thrombolysis in acute myocardial infarction: a technique for imaging thallium distribution before and after therapy

    International Nuclear Information System (INIS)

    Parker, J.A.; Markis, J.E.; Silverman, K.J.

    1982-01-01

    Intracoronary administration of streptokinase during the acute phase of myocardial infarction results in recanalization of the occluded coronary artery in a high percentage of patients. A technique is developed to investigate the acute effect of thrombolysis on the perfusion to viable myocardium using intracoronary administration of thallium-201. With intracoronary administration a very small initial dose of thallium can be used. Thus, a second scan can be performed after therapy, using a normal dose with only minimal contribution from the baseline study

  18. Comparison of electrocardiography and thallium-201 myocardial scintigraphy for the detection of ergonovine-induced coronary artery spasm: angiographic correlation

    International Nuclear Information System (INIS)

    Shanes, J.G.; Pavel, D.; Blend, M.

    1987-01-01

    This study was performed to determine the sensitivity of thallium imaging vs ECG monitoring for detecting coronary artery spasm noninvasively following intravenous ergonovine administration as compared to simultaneous coronary angiography. Thirty-two patients with insignificant coronary artery disease and chest pain underwent 12-lead ECG monitoring, thallium imaging, and coronary arteriography following the administration of 0.05, 0.1, 0.2, and 0.3 mg of ergonovine given 5 minutes apart or until chest pain occurred. One minute following the last dose of ergonovine, 2.5 mCi of thallium-201 was injected intravenously, and a final ECG was recorded and repeat coronary arteriography performed. Within 10 minutes following the injection of thallium, imaging was performed in the 40-degree and 70-degree left anterior oblique and anterior projections. The ECG, thallium study, and coronary arteriogram were read blindly and results were compared. The ECG, angiogram, and thallium study were read as positive if the following occurred, respectively: greater than or equal to 1 mm ST segment elevation, depression, or T wave reversal; greater than 50% vessel narrowing,; and reversible perfusion defect. Five patients were excluded from analysis because of either catheter-induced spasm, suboptimal thallium studies, or protocol violations. Of the 27 patients included for analysis, six had chest pain, five had a positive angiogram, five had a positive thallium study, and one had a positive ECG. The sensitivity of thallium vs ECG monitoring was 80% vs 25%, and the accuracy was 92% vs 80%. We conclude that thallium imaging greatly increases the noninvasive detection of ergonovine-induced coronary spasm as compared with the ECG with no loss of accuracy

  19. Whole-body MR imaging including angiography: Predicting recurrent events in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Bertheau, Robert C.; Kauczor, Hans-Ulrich; Weckbach, Sabine; Schlett, Christopher L. [University Hospital Heidelberg, Department of Diagnostic and Interventional Radiology, Heidelberg (Germany); Bamberg, Fabian [Ludwig Maximilians University, Klinikum Grosshadern, Department of Clinical Radiology, Munich (Germany); University Hospital Tuebingen, Department of Diagnostic and Interventional Radiology, Tuebingen (Germany); Lochner, Elena [Ludwig Maximilians University, Klinikum Grosshadern, Department of Clinical Radiology, Munich (Germany); Findeisen, Hannes M. [University Hospital Muenster, Department of Cardiology and Angiology, Muenster (Germany); Parhofer, Klaus G. [Ludwig Maximilians University, Klinikum Grosshadern, Department of Internal Medicine II, Munich (Germany); Schoenberg, Stefan O. [University Medical Center Mannheim, Department of Clinical Radiology and Nuclear Medicine, Mannheim (Germany)

    2016-05-15

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30 %) developed one, 8 (13 %) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75 %, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63 %, p = 0.001), carotid artery stenosis (11/17/63 %, p = 0.005), peripheral artery stenosis (26/56/88 %, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. (orig.)

  20. Whole-body MR imaging including angiography: Predicting recurrent events in diabetics

    International Nuclear Information System (INIS)

    Bertheau, Robert C.; Kauczor, Hans-Ulrich; Weckbach, Sabine; Schlett, Christopher L.; Bamberg, Fabian; Lochner, Elena; Findeisen, Hannes M.; Parhofer, Klaus G.; Schoenberg, Stefan O.

    2016-01-01

    Whether whole-body MRI can predict occurrence of recurrent events in patients with diabetes mellitus. Whole-body MRI was prospectively applied to 61 diabetics and assessed for arteriosclerosis and ischemic cerebral/myocardial changes. Occurrence of cardiocerebral events and diabetic comorbidites was determined. Patients were stratified whether no, a single or recurrent events arose. As a secondary endpoint, events were stratified into organ system-specific groups. During a median follow-up of 70 months, 26 diabetics developed a total of 39 events; 18 (30 %) developed one, 8 (13 %) recurrent events. Between diabetics with no, a single and recurrent events, a stepwise higher burden was observed for presence of left ventricular (LV) hypo-/akinesia (3/28/75 %, p < 0.0001), myocardial delayed-contrast-enhancement (17/33/63 %, p = 0.001), carotid artery stenosis (11/17/63 %, p = 0.005), peripheral artery stenosis (26/56/88 %, p = 0.0006) and vessel score (1.00/1.30/1.76, p < 0.0001). After adjusting for clinical characteristics, LV hypo-/akinesia (hazard rate ratio = 6.57, p < 0.0001) and vessel score (hazard rate ratio = 12.29, p < 0.0001) remained independently associated. Assessing organ system risk, cardiac and cerebral MR findings predicted more strongly events in their respective organ system. Vessel-score predicted both cardiac and cerebral, but not non-cardiocerebral, events. Whole-body MR findings predict occurrence of recurrent events in diabetics independent of clinical characteristics, and may concurrently provide organ system-specific risk. (orig.)

  1. Usefulness of semiquantitative analysis of dipyridamole-thallium-201 redistribution for improving risk stratification before vascular surgery

    International Nuclear Information System (INIS)

    Levinson, J.R.; Boucher, C.A.; Coley, C.M.; Guiney, T.E.; Strauss, H.W.; Eagle, K.A.

    1990-01-01

    Preoperative dipyridamole-thallium-201 scanning is sensitive in identifying patients prone to ischemic cardiac complications after vascular surgery, but most patients with redistribution do not have an event after surgery. Therefore, its positive predictive value is limited. To determine which patients with thallium redistribution are at highest risk, dipyridamole-thallium-201 images were interpreted semiquantitatively. Sixty-two consecutive patients with redistribution on preoperative dipyridamole-thallium-201 planar imaging studies were identified. Each thallium scan was then analyzed independently by 2 observers for the number of myocardial segments out of 15, the number of thallium views out of 3 and the number of coronary artery territories with redistribution. Seventeen patients (27%) had postoperative ischemic events, including unstable angina pectoris, ischemic pulmonary edema, myocardial infarction and cardiac death. Thallium predictors of ischemic operative complications included thallium redistribution greater than or equal to 4 myocardial segments (p = 0.03), greater than or equal to 2 of the 3 planar views (p = 0.005) and greater than or equal to 2 coronary territories (p = 0.007). No patient with redistribution in only 1 view had an ischemic event (0 of 15). Thus, determining the extent of redistribution by dipyridamole-thallium-201 scanning improves risk stratification before vascular surgery. Patients with greater numbers of myocardial segments and greater numbers of coronary territories showing thallium-201 redistribution are at higher risk for ischemic cardiac complications. In contrast, when the extent of thallium redistribution is limited, there is a lower risk despite the presence of redistribution

  2. Thallium poisoning. Diagnosis may be elusive but alopecia is the clue.

    Science.gov (United States)

    Moore, D; House, I; Dixon, A

    1993-01-01

    Thallium is a heavy metal whose salts are used in some rodent poisons and in the manufacture of optical lenses, semiconductors, scintillation counters, low temperature thermometers, and switching devices, green coloured fireworks, and imitation jewelery, and as chemical catalysts. In clinical practice thallium isotopes are used in cardiac scanning, but the use of thallium salts to treat scalp ringworm was abandoned earlier this century because of their toxicity. The sale of thallium in Britain is strictly licensed because of its toxicity and potential for use in murder, which is helped by the fact that thallous salts are colourless, tasteless, and odorless. The more water soluble salts (such as thallium sulphate, acetate, or carbonate) have higher toxicity, and although the toxic dose is variable most deaths occur after the ingestion of 10-15 mg/kg of soluble salt. Most cases of thallium toxicity occur after oral ingestion but severe toxicity has been reported after inhalation of contaminated dust from pyrite burners, in zinc and lead smelting, and in the manufacture of cadmium, after dermal absorption through protective rubber gloves, and after snorting what was thought to be cocaine. The elimination half time of thallium is between 1.7 and 30 days depending on the time since, and chronicity of, ingestion. The elimination time phases are apparent and because of the long terminal elimination half time thallium may act as a cumulative poison. We present two cases of thallium poisoning with intent to kill. Images FIG 3 PMID:8518684

  3. Unsuspected Widespread Cardiac Sarcoma in a Child

    OpenAIRE

    Spieth, Michael E.; Kasner, Darcy I.; Prasannan, Latha

    2003-01-01

    The case of a patient with an undifferentiated metastatic cardiac sarcoma is presented. A thallium-201 tumor study was performed to evaluate lung nodules. Thallium-201 chloride was injected intravenously and whole body images, as well as single photon emission computer tomography (SPECT) imaging of the chest, were obtained and reconstructed. They were displayed in three planes and then reconstructed again in cardiac planes. Multiple unsuspected metastases were found in the lower extremities. ...

  4. Utility of Postmortem Autopsy via Whole-Body Imaging: Initial Observations Comparing MDCT and 3.0T MRI Findings with Autopsy Findings

    International Nuclear Information System (INIS)

    Cha, Jang Gyu; Kim, Dong Hun; Paik, Sang Hyun

    2010-01-01

    We prospectively compared whole-body multidetector computed tomography (MDCT) and 3.0T magnetic resonance (MR) images with autopsy findings. Five cadavers were subjected to whole-body, 16- channel MDCT and 3.0T MR imaging within two hours before an autopsy. A radiologist classified the MDCT and 3.0T MRI findings into major and minor findings, which were compared with autopsy findings. Most of the imaging findings, pertaining to head and neck, heart and vascular, chest, abdomen, spine, and musculoskeletal lesions, corresponded to autopsy findings. The causes of death that were determined on the bases of MDCT and 3.0T MRI findings were consistent with the autopsy findings in four of five cases. CT was useful in diagnosing fatal hemorrhage and pneumothorax, as well as determining the shapes and characteristics of the fractures and the direction of external force. MRI was effective in evaluating and tracing the route of a metallic object, soft tissue lesions, chronicity of hemorrhage, and bone bruises. A postmortem MDCT combined with MRI is a potentially powerful tool, providing noninvasive and objective measurements for forensic investigations

  5. Slow late myocardial clearance of thallium: a characteristic phenomenon in coronary artery disease

    International Nuclear Information System (INIS)

    Sklar, J.; Kirch, D.; Johnson, T.; Hasegawa, B.; Peck, S.; Steele, P.

    1982-01-01

    Researchers extended the quantitative seven-pinhole method to follow the dynamics of thallium redistribution after exercise. Researchers observed a pattern of slow late thallium clearance that appears to be characteristic of myocardium supplied by obstructed coronary arteries. In 28 subjects, quantitative thallium scintigrams and blood samples for thallium concentration were taken immediately, 2 hours and 4 hours after maximal treadmill exercise. Twenty subjects had coronary artery disease (CAD) and eight were normal. The rate of thallium clearance from the blood (TCB) was compared with the rate of thallium clearance from each segmental region of myocardium between the 2- and 4-hour images. In seven of the eight normal subjects, TCM exceeded TCB in all regions of all images. Seventeen of the 20 CAD patients had at least one region where TCM was less than TCB. Of the 13 patients with multivessel CAD 11 had multiple regions with TCM less than TCB. Using this criterion, we detected 31 of 39 obstructed coronary arteries. Of the 37 regions that were abnormal by this analysis, 30 corresponded to obstructed coronary arteries. In contrast, while conventional circumferential count profile analysis also was abnormal in 17 of the 20 CAD patients, it diagnosed multivessel CAD in only five of the 13 patients that had it. These results show that slow late thallium clearance from myocardium is characteristic of regions of myocardium supplied by diseased coronary arteries and that observation of this phenomenon may improve diagnostic sensitivity for the presence of multivessel CAD

  6. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    International Nuclear Information System (INIS)

    Lacic, K.; Bokulic, T.; Lukac, J.; Dakovic, N.; Kusic, Z.

    1994-01-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more 'hot' and less 'cold' lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more 'hot' lesions than 4-6 hours SPECT. At the same time the number of 'cold' lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author)

  7. Comparison of SPECT and whole-body planar imaging in radioimmunoscintigraphy with Tc-labeled antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Lacic, K; Bokulic, T; Lukac, J; Dakovic, N; Kusic, Z [Clinical Hospital Sestre Milosrdnice, Zagreb (Croatia). Dept. of Oncology and Nuclear Medicine

    1994-10-01

    The authors of some recent clinical studies suggested 20-24 hours SPECT imaging as a mandatory procedure in radioimmunoscintigraphy with Tc-labeled antibodies. The aim of our study was to compare whole-body (WB) planar imaging versus SPECT as well as 4-6 hours SPECT to 20-24 hours one. For this purpose we analyzed 33 lesions in 12 postsurgical patients with colorectal carcinoma. Each patient received intravenously 0.5-1.0 mg anti-CEA BW 431/26 murine monoclonal IgG-antibodies labeled with Tc-99m (814-1110 MBq). WB and SPECT imaging were performed at 4-6 and 20-24 hours post infusion. 20-24 hours WB scan imaged more `hot` and less `cold` lesions than 4-6 hours one. SPECT scan showed significantly more lesions than WB scan. 20-24 hours SPECT scan detected more `hot` lesions than 4-6 hours SPECT. At the same time the number of `cold` lesions decreased in 20-24 hours SPECT in comparison to 4-6 hours one. As a conclusion we can say that our results suggest a superiority of SPECT imaging in comparison to WB scan. Except that, in our opinion performing of a 20-24 hours SPECT scan in radioimmunoscintigraphy with Tc-labeled antibodies should be mandatory. (author).

  8. Conjugate whole-body scanning system for quantitative measurement of organ distribution in vivo

    International Nuclear Information System (INIS)

    Tsui, B.M.W.; Chen, C.T.; Yasillo, N.J.; Ortega, C.J.; Charleston, D.B.; Lathrop, K.A.

    1979-01-01

    The determination of accurate, quantitative, biokinetic distribution of an internally dispersed radionuclide in humans is important in making realistic radiation absorbed dose estimates, studying biochemical transformations in health and disease, and developing clinical procedures indicative of abnormal functions. In order to collect these data, a whole-body imaging system is required which provides both adequate spatial resolution and some means of absolute quantitation. Based on these considerations, a new whole-body scanning system has been designed and constructed that employs the conjugate counting technique. The conjugate whole-body scanning system provides an efficient and accurate means of collecting absolute quantitative organ distribution data of radioactivity in vivo

  9. Whole-body biodistribution, radiation absorbed dose, and brain SPET imaging with [{sup 123}I]5-I-A-85380 in healthy human subjects

    Energy Technology Data Exchange (ETDEWEB)

    Fujita, Masahiro; Tamagnan, G.; Baldwin, R.M.; Khan, S.; Bozkurt, A. [Yale Univ., New Haven, CT (United States). School of Medicine; Seibyl, J.P.; Early, M. [Institute for Neurodegenerative Disorders, New Haven, CT (United States); Vaupel, B.D.; Horti, A.G.; Mukhin, A.G.; Kimes, A.S. [Brain Imaging Center, Intramural Research Program, National Institute on Drug Abuse, Baltimore, MD (United States); Zoghbi, S.S. [Yale Univ., New Haven, CT (United States). Dept. of Radiology; Koren, A.O.; London, E.D. [Brain Imaging Center, Intramural Research Program, National Institute on Drug Abuse, Baltimore, MD (United States); Departments of Psychiatry and Biobehavioral Sciences, UCLA, Los Angeles, CA (United States); Innis, R.B. [Molecular Imaging Branch, National Institutes of Mental Health (United States)

    2002-02-01

    The biodistribution of radioactivity after the administration of a new tracer for {alpha}4{beta}2 nicotinic acetylcholine receptors (nAChRs), [{sup 123}I]5-iodo-3-[2(S)-2-azetidinylmethoxy]pyridine (5-I-A-85380), was studied in ten healthy human subjects. Following administration of 98{+-}6 MBq [{sup 123}I]5-I-A-85380, serial whole-body images were acquired over 24 h and corrected for attenuation. One to four brain single-photon emission tomography (SPET) images were also acquired between 2.5 and 24 h. Estimates of radiation absorbed dose were calculated using MIRDOSE 3.1 with a dynamic bladder model and a dynamic gastrointestinal tract model. The estimates of the highest absorbed dose ({mu}Gy/MBq) were for the urinary bladder wall (71 and 140), lower large intestine wall (70 and 72), and upper large intestine wall (63 and 64), with 2.4-h and 4.8-h urine voiding intervals, respectively. The whole brain activity at the time of the initial whole-body imaging at 14 min was 5.0% of the injected dose. Consistent with the known distribution of {alpha}4{beta}2 nAChRs, SPET images showed the highest activity in the thalamus. These results suggest that [{sup 123}I]5-I-A-85380 is a promising SPET agent to image {alpha}4{beta}2 nAChRs in humans, with acceptable dosimetry and high brain uptake. (orig.)

  10. Quantitative assessment of thallium myocardial washout rate: Importance of peak heart rate and lung thallium uptake in defining normal values

    International Nuclear Information System (INIS)

    Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Kozuka, Takahiro; Saito, Muneyasu; Sumiyoshi, Tetsuya; National Cardiovascular Center, Suita, Osaka

    1987-01-01

    Traditionally, the results of exercise thallium scintigraphy were interpreted by transient defect analysis using initial and delayed images. Recently, washout rate analysis has been used for the relative quantification of exercise thallium scintigraphy. A diffuse slow washout from all myocardial regions has been defined as the indicator of extensive coronary artery disease. However, slow washout has occasionally been observed in normal cases and in healthy myocardial segments which are not supplied by a stenosed artery in patients with single or double vessel disease. We evaluate the factors influencing washout rate in 100 normal patients and 63 patients with angina pectoris (33 cases of single vessel disease and 30 cases of double vessel disease). The washout rates were calculated using circumferential profile analysis. In normal patients, washout rate was closely related to peak heart rate (r=0.72) and inversely related to lung thallium uptake (r=-0.56). A diffuse slow washout was observed in seven (7%) of 100 normal patients, six (18%) of 33 cases of single vessel disease and eight (24%) of 30 cases of double vessel disease. The patients with diffuse slow washout showed significantly higher lung thallium uptake values and lower peak heart rates than those without diffuse slow washout (P<0.01). Thus, this false positive slow washout should be considered in the interpretation of quantitative exercise thallium scintigraphy. (orig.)

  11. Left ventricular aneurysm in short axis: a comparison of magnetic resonance, ultrasound and thallium-201 SPECT images

    International Nuclear Information System (INIS)

    Ahmad, M.; Johnson, R.F. Jr.; Fawcett, H.D.; Schreiber, M.H.

    1987-01-01

    Short axis magnetic resonance images of a left ventricular aneurysm were compared to similar views obtained by echocardiography and by thallium-201 single photon emission computed tomography. Images of the dyskinetic left ventricular apex and the contractile left ventricular base were analyzed and compared. Unlike the previously reported orthogonal plane magnetic resonance images, short axis imaging provided representative and quantitative information in views comparable to those obtained by standard noninvasive imaging techniques. These data indicate that short axis magnetic resonance imaging is capable of identifying and sizing the aneurysmal and the residual segments of the left ventricle. The findings may be of prognostic value in patients with left ventricular aneurysm

  12. Diagnostic performance of 18F-FDG PET/CT and whole-body diffusion-weighted imaging with background body suppression (DWIBS) in detection of lymph node and bone metastases from pediatric neuroblastoma.

    Science.gov (United States)

    Ishiguchi, Hiroaki; Ito, Shinji; Kato, Katsuhiko; Sakurai, Yusuke; Kawai, Hisashi; Fujita, Naotoshi; Abe, Shinji; Narita, Atsushi; Nishio, Nobuhiro; Muramatsu, Hideki; Takahashi, Yoshiyuki; Naganawa, Shinji

    2018-04-17

    Recent many studies have shown that whole body "diffusion-weighted imaging with background body signal suppression" (DWIBS) seems a beneficial tool having higher tumor detection sensitivity without ionizing radiation exposure for pediatric tumors. In this study, we evaluated the diagnostic performance of whole body DWIBS and 18 F-FDG PET/CT for detecting lymph node and bone metastases in pediatric patients with neuroblastoma. Subjects in this retrospective study comprised 13 consecutive pediatric patients with neuroblastoma (7 males, 6 females; mean age, 2.9 ± 2.0 years old) who underwent both 18 F-FDG PET/CT and whole-body DWIBS. All patients were diagnosed as neuroblastoma on the basis of pathological findings. Eight regions of lymph nodes and 17 segments of skeletons in all patients were evaluated. The images of 123 I-MIBG scintigraphy/SPECT-CT, bone scintigraphy/SPECT, and CT were used to confirm the presence of lymph node and bone metastases. Two radiologists trained in nuclear medicine evaluated independently the uptake of lesions in 18 F-FDG PET/CT and the signal-intensity of lesions in whole-body DWIBS visually. Interobserver difference was overcome through discussion to reach a consensus. The sensitivities, specificities, and overall accuracies of 18 F-FDG PET/CT and whole-body DWIBS were compared using McNemer's test. Positive predictive values (PPVs) and negative predictive values (NPVs) of both modalities were compared using Fisher's exact test. The total numbers of lymph node regions and bone segments which were confirmed to have metastasis in the total 13 patients were 19 and 75, respectively. The sensitivity, specificity, overall accuracy, PPV, and NPV of 18 F-FDG PET/CT for detecting lymph node metastasis from pediatric neuroblastoma were 100, 98.7, 98.9, 95.0, and 100%, respectively, and those for detecting bone metastasis were 90.7, 73.1, 80.3, 70.1, and 91.9%, respectively. In contrast, the sensitivity, specificity, overall accuracy, PPV

  13. Prognostic value of exercise thallium-201 imaging in patients presenting for evaluation of chest pain

    International Nuclear Information System (INIS)

    Brown, K.A.; Boucher, C.A.; Okada, R.D.; Guiney, T.E.; Newell, J.B.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Accurate prognostic information is important in determining optimal management of patients presenting for evaluation of chest pain. In this study, the ability of exercise thallium-201 myocardial imaging to predict future cardiac events (cardiovascular death or nonfatal myocardial infarction) was correlated with clinical, coronary and left ventricular angiographic and exercise electrocardiographic data in 139 consecutive, nonsurgically managed patients followed-up over a 3 to 5 year period (mean follow-up, 3.7 +/- 0.9), using a logistic regression analysis. Among patients without prior myocardial infarction (100 of 139), the number of myocardial segments with transient thallium-201 defects was the only statistically significant predictor of future cardiac events when all patient variables were evaluated. Among patients with myocardial infarction before evaluation (39 of 139), angiographic ejection fraction was the only significant predictor of future cardiac events when all variables were considered. This study suggests an approach to evaluate the risk of future cardiac events in patients with possible ischemic heart disease

  14. A prototype PET/SPECT/X-rays scanner dedicated for whole body small animal studies.

    Science.gov (United States)

    Rouchota, Maritina; Georgiou, Maria; Fysikopoulos, Eleftherios; Fragogeorgi, Eirini; Mikropoulos, Konstantinos; Papadimitroulas, Panagiotis; Kagadis, George; Loudos, George

    2017-01-01

    To present a prototype tri-modal imaging system, consisting of a single photon emission computed tomography (SPET), a positron emission tomography (PET), and a computed tomography (CT) subsystem, evaluated in planar mode. The subsystems are mounted on a rotating gantry, so as to be able to allow tomographic imaging in the future. The system, designed and constructed by our group, allows whole body mouse imaging of competent performance and is currently, to the best of our knowledge, unequaled in a national and regional level. The SPET camera is based on two Position Sensitive Photomultiplier Tubes (PSPMT), coupled to a pixilated Sodium Iodide activated with Thallium (NaI(Tl)) scintillator, having an active area of 5x10cm 2 . The dual head PET camera is also based on two pairs of PSPMT, coupled to pixelated berillium germanium oxide (BGO) scintillators, having an active area of 5x10cm 2 . The X-rays system consists of a micro focus X-rays tube and a complementary metal-oxide-semiconductor (CMOS) detector, having an active area of 12x12cm 2 . The scintigraphic mode has a spatial resolution of 1.88mm full width at half maximum (FWHM) and a sensitivity of 107.5cpm/0.037MBq at the collimator surface. The coincidence PET mode has an average spatial resolution of 3.5mm (FWHM) and a peak sensitivity of 29.9cpm/0.037MBq. The X-rays spatial resolution is 3.5lp/mm and the contrast discrimination function value is lower than 2%. A compact tri-modal system was successfully built and evaluated for planar mode operation. The system has an efficient performance, allowing accurate and informative anatomical and functional imaging, as well as semi-quantitative results. Compared to other available systems, it provides a moderate but comparable performance, at a fraction of the cost and complexity. It is fully open, scalable and its main purpose is to support groups on a national and regional level and provide an open technological platform to study different detector components and

  15. Direct comparison of radiation dosimetry of six PET tracers using human whole-body imaging and murine biodistribution studies

    International Nuclear Information System (INIS)

    Sakata, Muneyuki; Oda, Keiichi; Toyohara, Jun; Ishii, Kenji; Nariai, Tadashi; Ishiwata, Kiichi

    2013-01-01

    We investigated the whole-body biodistributions and radiation dosimetry of five 11 C-labeled and one 18 F-labeled radiotracers in human subjects, and compared the results to those obtained from murine biodistribution studies. The radiotracers investigated were 11 C-SA4503, 11 C-MPDX, 11 C-TMSX, 11 C-CHIBA-1001, 11 C-4DST, and 18 F-FBPA. Dynamic whole-body positron emission tomography (PET) was performed in three human subjects after a single bolus injection of each radiotracer. Emission scans were collected in two-dimensional mode in five bed positions. Regions of interest were placed over organs identified in reconstructed PET images. The OLINDA program was used to estimate radiation doses from the number of disintegrations of these source organs. These results were compared with the predicted human radiation doses on the basis of biodistribution data obtained from mice by dissection. The ratios of estimated effective doses from the human-derived data to those from the mouse-derived data ranged from 0.86 to 1.88. The critical organs that received the highest absorbed doses in the human- and mouse-derived studies differed for two of the six radiotracers. The differences between the human- and mouse-derived dosimetry involved not only the species differences, including faster systemic circulation of mice and differences in the metabolism, but also measurement methodologies. Although the mouse-derived effective doses were roughly comparable to the human-derived doses in most cases, considerable differences were found for critical organ dose estimates and pharmacokinetics in certain cases. Whole-body imaging for investigation of radiation dosimetry is desirable for the initial clinical evaluation of new PET probes prior to their application in subsequent clinical investigations. (author)

  16. Whole body monitoring - Goiania

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de; Lourenco, M.C.; Bertelli Neto, L.; Lucena, E.A. de; Becker, P.H.B.

    1988-01-01

    Due to the radiological Cs accident in Goiania, Goias in September 1987, it became necessary to evaluate internal contamination levels of: - Individual from the general public that for any reason had direct or indirect involvement with the radioactive source (group 1). - Occupationally involved persons (group 2). For each of these groups, procedures of whole body monitoring were developped. In order to attend group 1 individuals, the IRD/CNEN installed a whole body unit in the INAMPS General Hospital of Goiania in 11.08.87, which was later transferred to 121,57 street, Central Sector in Goiania in 2.06.88. In this unit 547 people were monitored, 356 from group 1 and 241 from group 2, until 04.13.88. In the IRD whole body counter installation, 194 individuals were counted, 185 from group 2 and 9 from group 1. The frequency of monitoring of each individual was established according to the Cs activity present in the body or to the job to be assigned. In this paper we will present some burden activity curves for Cs 137 as a function of the time elapsed from the first measurement. There people from group 1 were measured in both counters, the IRD and the Goiania ones. The values obtained in both installations are compatible with the body activity x time curve. (author) [pt

  17. Time sequential single photon emission computed tomography studies in brain tumour using thallium-201

    International Nuclear Information System (INIS)

    Ueda, Takashi; Kaji, Yasuhiro; Wakisaka, Shinichiro; Watanabe, Katsushi; Hoshi, Hiroaki; Jinnouchi, Seishi; Futami, Shigemi

    1993-01-01

    Time sequential single photon emission computed tomography (SPECT) studies using thallium-201 were performed in 25 patients with brain tumours to evaluate the kinetics of thallium in the tumour and the biological malignancy grade preoperatively. After acquisition and reconstruction of SPECT data from 1 min post injection to 48 h (1, 2, 3, 4, 5, 6, 7, 8, 9, 10 and 15-20 min, followed by 4-6, 24 and 48 h), the thallium uptake ratio in the tumour versus the homologous contralateral area of the brain was calculated and compared with findings of X-ray CT, magnetic resonance imaging, cerebral angiography and histological investigations. Early uptake of thallium in tumours was related to tumour vascularity and the disruption of the blood-brain barrier. High and rapid uptake and slow reduction of thallium indicated a hypervascular malignant tumour; however, high and rapid uptake but rapid reduction of thallium indicated a hypervascular benign tumour, such as meningioma. Hypovascular and benign tumours tended to show low uptake and slow reduction of thallium. Long-lasting retention or uptake of thallium indicates tumour malignancy. (orig.)

  18. The clinical role of thallium-201 scintigraphy in the management and prognosis of coronary artery disease

    International Nuclear Information System (INIS)

    Gammage, M.D.; Murray, D.P.; Rafiqi, E.; Murray, R.G.

    1984-01-01

    To determine the clinical impact of thallium-201 scintigraphy in coronary artery disease, the indications, diagnostic yield and contribution to patient management were reviewed retrospectively in 103 patients referred for routine investigations. Exercise and redistribution image data were collected in multiple projections and interpreted by visual and semi-quantitative means. A segmental image defect was accepted as indicating the presence of coronary artery disease. Thallium-201 scintigraphy was performed as a diagnostic procedure in 71 patients (69%) who had equivocal evidence of coronary artery disease. In 57 (80%) of these patients, thallium-201 scintigraphy was normal and 53 (75%) were spared diagnostic coronary arteriography. Despite normal thallium-201 scintigrams, arteriography was performed in 4 patients with persisting symptoms and demonstrated normal vessels in 2 patients and single vessel disease in 2 patients. Conversely, arteriography was normal in 2 of 14 patients (14%) with unequivocal image defects. Thallium-201 scintigraphy was performed as a functional complement to coronary arteriography in 32 patients, influencing the decision for coronary surgery in 10, for angioplasty in 4 and against surgery in 2. Myocardial ischaemia was confirmed in 8 and refuted in 8 patients with questionable arteriographic coronary disease. Positive management decisions were taken as a result of thallium-201 scintigraphy in 80 of these 103 patients (78%). These data confirm the vital role of thallium-201 scintigraphy in the evaluation and management of patients with suspected and proven coronary artery disease. (orig.)

  19. Evaluation of the utility of temporal subtraction images in successive whole-body bone scans: a prospective clinical study

    International Nuclear Information System (INIS)

    Shiraishi, J.; Appelbaum, D.; Pu, Y.; Engelmann, R.; Li Qiang; Doi, K.

    2007-01-01

    We have begun a prospective clinical study for evaluating the clinical utility of temporal subtraction images in successive whole-body bone scans. The computerized temporal subtraction technique has been developed in order to highlight interval changes of abnormal lesions due to skeletal metastases, primary bone tumors, osteomyelitis, and fractures. In our initial preliminary results of the prospective study which was started on November 22, 2006 in our hospital, radiologists reported some interval changes which were not recognized in the initial standard readings, but were obvious when temporal subtraction images were viewed. The usefulness of the temporal subtraction images will be investigated in terms of its clinical utility by the prospective clinical study. (orig.)

  20. Adaptive statistical iterative reconstruction technology in the application of PET/CT whole body scans

    International Nuclear Information System (INIS)

    Xin Jun; Zhao Zhoushe; Li Hong; Lu Zhe; Wu Wenkai; Guo Qiyong

    2013-01-01

    Objective: To improve image quality of low dose CT in whole body PET/CT using adaptive statistical iterative reconstruction (ASiR) technology. Methods: Twice CT scans were performed with GE water model,scan parameters were: 120 kV, 120 and 300 mA respectively. In addition, 30 subjects treated with PET/CT were selected randomly, whole body PET/CT were performed after 18 F-FDG injection of 3.70 MBq/kg, Sharp IR+time of flight + VUE Point HD technology were used for 1.5 min/bed in PET; CT of spiral scan was performed under 120 kV using automatic exposure control technology (30-210 mA, noise index 25). Model and patients whole body CT images were reconstructed with conventional and 40% ASiR methods respectively, and the CT attenuation value and noise index were measured. Results: Research of model and clinical showed that standard deviation of ASiR method in model CT was 33.0% lower than the conventional CT reconstruction method (t =27.76, P<0.01), standard deviation of CT in normal tissues (brain, lung, mediastinum, liver and vertebral body) and lesions (brain, lung, mediastinum, liver and vertebral body) reduced by 21.08% (t =23.35, P<0.01) and 24.43% (t =16.15, P<0.01) respectively, especially for normal liver tissue and liver lesions, standard deviations of CT were reduced by 51.33% (t=34.21, P<0.0) and 49.54% (t=15.21, P<0.01) respectively. Conclusion: ASiR reconstruction method was significantly reduced the noise of low dose CT image and improved the quality of CT image in whole body PET/CT, which seems more suitable for quantitative analysis and clinical applications. (authors)

  1. [Graphite furnace atomic absorption spectrometry for determination of thallium in blood].

    Science.gov (United States)

    Zhang, Q L; Gao, G

    2016-04-20

    Colloidal palladium was used as chemical modifier in the determination of blood thallium by graphite furnace atomic absorption spectrometry. Blood samples were precipitated with 5% (V/V)nitric acid, and then determined by GFAAS with colloidal palladium used as a chemical modifier. 0.2% (W/V)sodium chloride was added in the standard series to improve the matrix matching between standard solution and sample. The detection limit was 0.2 μg/L. The correlation coefficient was 0.9991. The recoveries were between 93.9% to 101.5%.The relative standard deviations were between 1.8% to 2.7%.The certified reference material of whole blood thallium was determined and the result was within the reference range Conclusion: The method is accurate, simple and sensitive, and it can meet the needs of detection thallium in blood entirely.

  2. Detection of human collateral circulation by vasodilation-thallium-201 tomography

    International Nuclear Information System (INIS)

    Nienaber, C.A.; Salge, D.; Spielmann, R.P.; Montz, R.; Bleifeld, W.

    1990-01-01

    Coronary arteriolar vasodilation may provoke redistribution of flow to collateral-dependent jeopardized myocardium. To assess the physiologic significance of collaterals, 80 consecutive post-infarction patients (age 58 +/- 8 years) underwent vasodilation-redistribution thallium-201 tomographic imaging after administration of 0.56 mg of intravenous dipyridamole/kg body weight. Circumferential profile analysis of thallium-201 uptake and redistribution in representative left ventricular tomograms provided quantitative assessment of transient and fixed defects and separation between periinfarctional and distant inducible hypoperfusion. Tomographic perfusion data were correlated to wall motion and collateral circulation between distinct anatomic perfusion territories. Patients were grouped according to presence (59%) or absence (41%) of angiographically visible collateral channels to jeopardized myocardium. In the presence of collaterals, distant reversible defects were larger than in absence of collaterals (p less than 0.05); the extent of combined periinfarctional and distant redistribution was also larger in collateralized patients (p less than 0.025), whereas the size of the persistent perfusion defect was similar in both groups. By prospective analysis the tomographic perfusion pattern of combined periinfarctional and distant redistribution revealed a sensitivity of 85% and a specificity of 78% for the detection of significant collateral circulation in this group of patients. Thus, using the exhausted flow reserve as a diagnostic tool, vasodilation-thallium-201 tomography has the potential to identify and quantitate collateralized myocardium in post-infarction patients and may guide diagnostic and therapeutic decision-making

  3. A novel triple-modality reporter gene for whole-body fluorescent, bioluminescent, and nuclear noninvasive imaging

    International Nuclear Information System (INIS)

    Ponomarev, Vladimir; Vider, Jelena; Shavrin, Aleksander; Ageyeva, Ludmila; Tourkova, Vilia; Doubrovin, Michael; Serganova, Inna; Beresten, Tatiana; Ivanova, Anna; Blasberg, Ronald; Balatoni, Julius; Bornmann, William; Gelovani Tjuvajev, Juri

    2004-01-01

    Two genetic reporter systems were developed for multimodality reporter gene imaging of different molecular-genetic processes using fluorescence, bioluminescence (BLI), and nuclear imaging techniques. The eGFP cDNA was fused at the N-terminus with HSV1-tk cDNA bearing a nuclear export signal from MAPKK (NES-HSV1-tk) or with truncation at the N-terminus of the first 45 amino acids (Δ45HSV1-tk) and with firefly luciferase at the C-terminus. A single fusion protein with three functional subunits is formed following transcription and translation from a single open reading frame. The NES-TGL (NES-TGL) or Δ45HSV1-tk/GFP/luciferase (Δ45-TGL) triple-fusion gene cDNAs were cloned into a MoMLV-based retrovirus, which was used for transduction of U87 human glioma cells. The integrity, fluorescence, bioluminescence, and enzymatic activity of the TGL reporter proteins were assessed in vitro. The predicted molecular weight of the fusion proteins (130 kDa) was confirmed by western blot. The U87-NES-TGL and U87-Δ45-TGL cells had cytoplasmic green fluorescence. The in vitro BLI was 7- and 13-fold higher in U87-NES-TGL and U87-Δ45-TGL cells compared to nontransduced control cells. The Ki of 14 C-FIAU was 0.49±0.02, 0.51±0.03, and 0.003±0.001 ml/min/g in U87-NES-TGL, U87-Δ45-TGL, and wild-type U87 cells, respectively. Multimodality in vivo imaging studies were performed in nu/nu mice bearing multiple s.c. xenografts established from U87-NES-TGL, U87-Δ45-TGL, and wild-type U87 cells. BLI was performed after administration of d-luciferin (150 mg/kg i.v.). Gamma camera or PET imaging was conducted at 2 h after i.v. administration of [ 131 I]FIAU (7.4 MBq/animal) or [ 124 I]FIAU (7.4 MBq/animal), respectively. Whole-body fluorescence imaging was performed in parallel with the BLI and radiotracer imaging studies. In vivo BLI and gamma camera imaging showed specific localization of luminescence and radioactivity to the TGL transduced xenografts with background levels of activity

  4. Lean body mass correction of standardized uptake value in simultaneous whole-body positron emission tomography and magnetic resonance imaging

    Science.gov (United States)

    Jochimsen, Thies H.; Schulz, Jessica; Busse, Harald; Werner, Peter; Schaudinn, Alexander; Zeisig, Vilia; Kurch, Lars; Seese, Anita; Barthel, Henryk; Sattler, Bernhard; Sabri, Osama

    2015-06-01

    This study explores the possibility of using simultaneous positron emission tomography—magnetic resonance imaging (PET-MRI) to estimate the lean body mass (LBM) in order to obtain a standardized uptake value (SUV) which is less dependent on the patients' adiposity. This approach is compared to (1) the commonly-used method based on a predictive equation for LBM, and (2) to using an LBM derived from PET-CT data. It is hypothesized that an MRI-based correction of SUV provides a robust method due to the high soft-tissue contrast of MRI. A straightforward approach to calculate an MRI-derived LBM is presented. It is based on the fat and water images computed from the two-point Dixon MRI primarily used for attenuation correction in PET-MRI. From these images, a water fraction was obtained for each voxel. Averaging over the whole body yielded the weight-normalized LBM. Performance of the new approach in terms of reducing variations of 18F-Fludeoxyglucose SUVs in brain and liver across 19 subjects was compared with results using predictive methods and PET-CT data to estimate the LBM. The MRI-based method reduced the coefficient of variation of SUVs in the brain by 41  ± 10% which is comparable to the reduction by the PET-CT method (35  ± 10%). The reduction of the predictive LBM method was 29  ± 8%. In the liver, the reduction was less clear, presumably due to other sources of variation. In conclusion, employing the Dixon data in simultaneous PET-MRI for calculation of lean body mass provides a brain SUV which is less dependent on patient adiposity. The reduced dependency is comparable to that obtained by CT and predictive equations. Therefore, it is more comparable across patients. The technique does not impose an overhead in measurement time and is straightforward to implement.

  5. Whole-body counters in Canada

    International Nuclear Information System (INIS)

    Letourneau, C.

    1986-08-01

    A compilation of whole-body counting existing across Canada was prepared by AECB (Atomic Energy Control Board) staff. This work was initiated so that AECB staff and other concerned parties would have this information readily available, especially during urgent situations. This report is to be used for reference purposes only, as it makes no attempt to judge the present state of the art of whole-body counting

  6. SYNCHROTRON X-RAY ABSORPTION-EDGE COMPUTED MICROTOMOGRAPHY IMAGING OF THALLIUM COMPARTMENTALIZATION IN IBERIS INTERMEDIA

    Science.gov (United States)

    Thallium (TI) is an extremely toxic metal which, due to its similarities to K, is readily taken up by plants. Thallium is efficiently hyperaccumulated in Iberis intermedia as TI(I). Distribution and compartmentalization of TI in I. intermedia is highes...

  7. Disseminated cysticercosis in a child: whole-body MR diagnosis with the use of parallel imaging

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Atin; Goenka, Ajit Harishkumar [All India Institute of Medical Sciences, Department of Radiology, New Delhi, Delhi (India); Choudhary, Anita; Sahu, Jitendra Kumar; Gulati, Sheffali [All India Institute of Medical Sciences, Department of Paediatrics, New Delhi, Delhi (India)

    2010-02-15

    Cysticercosis is a parasitic disease caused by infestation with the encysted larval stage of the pork tapeworm, Taenia solium. Disseminated cysticercosis is an exceptional expression of this disease characterized by high morbidity due to massive symptomatic parasite burden in the central nervous system, striated muscles, subcutaneous tissues and other organs. Less than 50 such cases have been reported worldwide, and fewer than 10 children. We report on the whole-body MR diagnosis of extensively disseminated cysticercosis in a child. The critical role of whole-body MR as a stand-alone modality in the diagnosis and management of this pleomorphic disease is highlighted. Whole-body MR diagnosis of an infectious disease is unique. (orig.)

  8. Clinical features and applications of thallium-201. With reference to scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, Tadashige

    1988-12-01

    Thallium-201 is not only used widely in myocardial imaging but also has a great potential in other various nuclear medicine imaging studies. This paper presents clinical features and applications of thallium-201, focusing on clinical trials with thallium-201 at the Shinshu University School of Medicine. Thallium-201 myocardial scintigraphy offers information on (1) ventricular position and morphology, (2) hypertrophy or dilatation of the left ventricle, (3) hypertrophy or dilatation of the right ventricle, (4) site and extent of myocardial ischemia and infarct, (5) myocardial blood flow, (6) pulmonary congestion or interstitial pulmonary edema, and (7) pericardial effusion. It can be used in the following evaluation or diagnosis: (1) acute or old myocardial infarction, (2) angina pectoris, (3) treatment strategy or prognosis of ischemic heart disease, (4) treatment strategy or observation of bypass graft or drug therapy, (5) hypertrophic or dilated idiopathic cardiomyopathy, (6) myocardial lesions induced by sarcoidosis, collagen disease, and neuro-muscular disease, (7) ventricular hypertrophy and pulmonary edema, and (9) pericarditis, pericardial effusion, and systolic pericarditis associated with underlying disease. The significance of tumor, liver, bone marrow scintigraphies is also referred to. (Namekawa, K) 69 refs.

  9. Assessing the fate and toxicity of Thallium I and Thallium III to three aquatic organisms.

    Science.gov (United States)

    Rickwood, C J; King, M; Huntsman-Mapila, P

    2015-05-01

    Thallium has been shown to significantly increase in both water and aquatic biota after exposure to metal mine effluent, however, there is a lack of knowledge as to its fate and effect in the aquatic environment. The objectives of this project were to assess (1) fate of thallium by conducting speciation analysis and determining the influence of water quality on toxicity and (2) effects of thallium (I) and (III) on three aquatic species; the algae, Pseudokirchneriella subcapitata, the invertebrate Ceriodaphnia dubia and the vertebrate Pimephales promelas. Speciation analysis proved challenging with poor recovery of thallium (I), however analysis with solutions >125μg/L revealed that over a 7-d period, recovery of thallium (III) was less than 15%, suggesting that the majority of thallium (III) was converted to Thallium (I). It was only in fresh solutions where recovery of Thallium (III) was greater than 80%. The lowest IC25s generated during our effects assessment for both Thallium (I) and (III) were more than 10-fold greater than the highest concentration recorded in receiving environments (8μg/L) and more than 100-fold greater than the current guideline (0.8μg/L). To assess the influence of water quality on thallium toxicity, the concentrations of both potassium and calcium were reduced in dilution water. When potassium was reduced for both C. dubia and P. subcapitata tests, the lowest IC25 generated was 5-fold higher than the current guideline, but within the range of concentrations reported in receiving environments for both Thallium (I) and (III). When calcium was reduced in dilution water, toxicity only increased in the Tl (III) tests with C. dubia; the IC25 for Tl(III), similar to the exposures conducted with reduced potassium, was within the range of total thallium concentrations reported in the receiving environment. Without an accurate, repeatable method to assess thallium speciation at low concentrations it is not possible to draw any firm conclusions

  10. An experimental test on large animals of MCNP application for whole body counting

    International Nuclear Information System (INIS)

    Borisov, N.; Yatsenko, V.; Kochetkov, O.; Gusev, I.; Vlasov, P.; Kalistratova, V.; Nisimov, P.; Levochkin, F.; Borovkov, M.; Stolyarov, V.; Tsedish, S.; Tyurin, I.; Franck, D.; Carlan, L. de

    2005-01-01

    Measurements of actinide body burden using whole body counting spectrometry is hampered due to intensive absorption of γ-rays inside the patient's body, which depends on the anatomy of a patient. To establish the correspondence between pulse-height-spectra intensity and radionuclide activity, Monte Carlo calculations are widely used. For such calculations, the radiation transport geometry is usually described in terms of small rectangular boxes (voxels) retrieved from computed tomography or magnetic resonance images. The software for Monte Carlo-assisted calibration of whole body counting, which performs automatic creation of individual MCNP voxel phantoms, was checked in a quasi-in vivo experiment on large animals. During the experiment, pigs of 35-40 kg body mass were used as phantoms for measurement of actinides body burden. 241 Am was administered (via injection of a radioactive solution or via implantation of plastic capsules containing the radioactive material) into the lungs of pigs. The pigs were measured using the pure germanium low-energy γ-spectrometers. The images of animals were obtained using the computed tomography machine. On the base of these tomograms, MCNP4c2 calculations were done to obtain the pulse-height-spectra of the whole body counters. The experimental results were reproduced in calculations with error of less than 30% for 241 Am administered via injection and less than 10% for 241 Am administered inside the capsules. (authors)

  11. Comparison of early thallium-201 scintigraphy and gated blood pool imaging for predicting mortality in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Becker, L.C.; Silverman, K.J.; Bulkley, B.H.; Kallman, C.H.; Mellits, E.D.; Weisfeldt, M.

    1983-01-01

    The extent of abnormality in early thallium-201 and gated cardiac blood pool scintigrams has been reported to be useful for predicting mortality in patients with acute myocardial infarction (AMI). To compare the two techniques, 91 patients admitted consecutively with evident or strongly suspected AMI underwent both imaging studies within 15 hours of the onset of symptoms. Patients with pulmonary edema or shock were excluded. AMI developed in 84% of patients, and 6-month mortality for the entire group was 16%. A thallium defect score of 7.0 or greater identified a subgroup of 14 patients with 64% 6-month mortality rate. Similarly, a left ventricular ejection fraction of 35% or less identified a high-risk subgroup of 10 patients with a 6-month mortality of 60%. Mortality in the remaining patients was 8% for thallium score less than 7 and 11% for ejection fraction greater than 35%. The mortality rate was highest among patients who had concordant high-risk scintigrams (five of six, 83%), lowest in those with concordant low-risk studies (five of 64, 8%) and intermediate in those with discordant results (four of 11, 36%). Of a number of clinical variables, only the appearance of Q waves, peak creatine kinase greater than 1000 IU/I, and history of infarction were significantly associated with mortality. High-risk thallium or blood pool scintigraphic results were significantly more predictive and a thallium score of 7 or greater was more sensitive for detecting nonsurvivors than ejection fraction 35% or less at a similar level of specificity

  12. Myocardial uptake and clearance of thallium-201 in normal subjects: comparison of dipyridamole-induced hyperemia with exercise stress

    International Nuclear Information System (INIS)

    Ruddy, T.D.; Gill, J.B.; Finkelstein, D.M.; Strauss, H.W.; McKusick, K.A.; Okada, R.D.; Boucher, C.A.

    1987-01-01

    Thallium-201 uptake and clearance after dipyridamole infusion may differ from that after exercise stress because the hemodynamic effects of these two interventions are different. In this study of normal volunteers, thallium kinetics after dipyridamole (n = 13) were determined from three serial image sets (early, intermediate and delayed) and from serial blood samples and compared with thallium kinetics after exercise (n = 15). Absolute myocardial thallium uptake was greater after dipyridamole compared with exercise (p less than 0.0001), although the relative myocardial distribution was similar. The myocardial clearance (%/h) of thallium was slower after dipyridamole than it was after exercise. Comparing dipyridamole and exercise, the differences in clearance were large from the early to the intermediate image (anterior, -11 +/- 17 versus 24 +/- 5, p = 0.0005; 50 degrees left anterior oblique, -7 +/- 11 versus 15 +/- 8, p = 0.004; 70 degrees left anterior oblique, 3 +/- 9 versus 21 +/- 6, p = 0.001). In contrast, the differences in clearance were small from the intermediate to the delayed image (anterior, 15 +/- 4 versus 20 +/- 2, p = 0.025; 50 degrees left anterior oblique, 15 +/- 4 versus 19 +/- 3, p = 0.13; 70 degrees left anterior oblique, 15 +/- 3 versus 18 +/- 2, p = 0.047). Thallium uptake and clearance in the liver, splanchnic region and spleen were greater after dipyridamole (p less than 0.001). Blood thallium levels were greater after dipyridamole (p less than 0.05) and cleared more slowly (p = 0.07). Thus, myocardial thallium-201 uptake and clearance after dipyridamole infusion differ from thallium kinetics after exercise. This difference is, in part, related to associated differences in extracardiac and blood kinetics. Diagnostic criteria for the detection of abnormal thallium-201 clearance must be specific for the type of intervention

  13. Measurement of whole body cellular and collagen nitrogen, potassium, and other elements by neutron activation and whole body counting

    International Nuclear Information System (INIS)

    James, H.M.; Fabricius, P.J.; Dykes, P.W.

    1987-01-01

    Whole body nitrogen can be measured by neutron activation analysis with an acceptable radiation dose; it is an index of body protein which, in normal subjects, is 65% cellular protein and 35% extracellular connective collagen. Whole body potassium can be measured by whole body counting without irradiating the subject; it is an index of body cell mass. We measured whole body nitrogen, potassium, extracellular water, intracellular water, and fat-folds. The differences between 37 malnourished patients and five normal subjects suggested that the patients had 9 kg less cell mass than normal, but no difference in extracellular mass. Measurements were made on eight patients before and after 14 days of total parenteral nutrition; balance of nitrogen intake and excretion also was measured. The changes were consistent with mean increases of 3 kg of cellular mass and 3 kg of fat with no change of extracellular mass. The accuracy and sensitivity of the whole body measurements need further confirmation for use in patients with changing body composition. Where tissue wasting is largely from the cellular compartment, potassium could be a more sensitive index of wasting than nitrogen. Multielement analysis of nitrogen, potassium, chlorine, and carbon will probably be valuable in elucidating body composition in malnutrition

  14. A randomized, double-blind, crossover comparison of novel continuous bed motion versus traditional bed position whole-body PET/CT imaging

    International Nuclear Information System (INIS)

    Schatka, Imke; Weiberg, Desiree; Reichelt, Stephanie; Owsianski-Hille, Nicole; Derlin, Thorsten; Berding, Georg; Bengel, Frank M.

    2016-01-01

    Continuous bed motion has recently been introduced for whole-body PET/CT, and represents a paradigm shift towards individualized and flexible acquisition without the limitations of bed position-based planning. Increased patient comfort due to lack of abrupt table position changes may be another albeit still unproven advantage. For robust clinical implementation, image quality and quantitative accuracy should at least be equal to the prior standard of bed position-based step-and-shoot imaging. The study included 68 consecutive patients referred for whole-body PET/CT for various malignancies. The patients underwent traditional step-and-shoot and novel continuous bed motion acquisition in the same session in a randomized crossover design. The patients and two independent observers were blinded to the sequence of scan techniques. Patient comfort/satisfaction was examined using a standardized questionnaire. SUVs were compared for reference tissue (liver, muscle) and tumour lesions. PET image quality and misalignment with CT images were evaluated on a scale of 1 - 4. Patients preferred continuous bed motion over step-and-shoot (P = 0.0001). It was considered to be more relaxing (38 % vs. 8 %), quieter (34 % vs. 8 %), and more fluid (64 % vs. 8 %). Image quality, SUV and CT misalignment did not differ between the techniques. Continuous bed motion resulted in better end-plane image quality (P < 0.0001). Regardless of the technique, second examinations had significantly higher tumour lesion SUVmax values (P = 0.0002), and a higher CT misalignment score (P = 0.0017). Oncological PET/CT with continuous bed motion enhances patient comfort and is associated with image quality at least comparable to that with traditional bed position-based step-and-shoot acquisition. (orig.)

  15. A randomized, double-blind, crossover comparison of novel continuous bed motion versus traditional bed position whole-body PET/CT imaging

    Energy Technology Data Exchange (ETDEWEB)

    Schatka, Imke [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany); Charite, Department of Nuclear Medicine, Berlin (Germany); Weiberg, Desiree; Reichelt, Stephanie; Owsianski-Hille, Nicole; Derlin, Thorsten; Berding, Georg; Bengel, Frank M. [Hannover Medical School, Department of Nuclear Medicine, Hannover (Germany)

    2016-04-15

    Continuous bed motion has recently been introduced for whole-body PET/CT, and represents a paradigm shift towards individualized and flexible acquisition without the limitations of bed position-based planning. Increased patient comfort due to lack of abrupt table position changes may be another albeit still unproven advantage. For robust clinical implementation, image quality and quantitative accuracy should at least be equal to the prior standard of bed position-based step-and-shoot imaging. The study included 68 consecutive patients referred for whole-body PET/CT for various malignancies. The patients underwent traditional step-and-shoot and novel continuous bed motion acquisition in the same session in a randomized crossover design. The patients and two independent observers were blinded to the sequence of scan techniques. Patient comfort/satisfaction was examined using a standardized questionnaire. SUVs were compared for reference tissue (liver, muscle) and tumour lesions. PET image quality and misalignment with CT images were evaluated on a scale of 1 - 4. Patients preferred continuous bed motion over step-and-shoot (P = 0.0001). It was considered to be more relaxing (38 % vs. 8 %), quieter (34 % vs. 8 %), and more fluid (64 % vs. 8 %). Image quality, SUV and CT misalignment did not differ between the techniques. Continuous bed motion resulted in better end-plane image quality (P < 0.0001). Regardless of the technique, second examinations had significantly higher tumour lesion SUVmax values (P = 0.0002), and a higher CT misalignment score (P = 0.0017). Oncological PET/CT with continuous bed motion enhances patient comfort and is associated with image quality at least comparable to that with traditional bed position-based step-and-shoot acquisition. (orig.)

  16. Preoperative imaging in primary hyperparathyroidism. Role of thallium-technetium subtraction scintigraphy

    International Nuclear Information System (INIS)

    Foster, G.S.; Bekerman, C.; Blend, M.J.; Byrom, E.; Pinsky, S.M.

    1989-01-01

    Primary hyperparathyroidism, although often silent clinically, may lead to significant morbidity if it remains untreated. In more than 95% of all cases the cause is a parathyroid adenoma or glandular hyperplasia. Regression of disease follows successful surgical excision of the abnormal parathyroid gland. Recurrent or persistent hyperparathyroidism is most commonly caused by solitary adenomas, which may have an ectopic location. Preoperative localization of lesions may improve postoperative cure rates and decrease morbidity. Thallium T1 201 chloride-technetium Tc 99m pertechnetate subtraction scintigraphy was performed on 15 patients with primary hyperparathyroidism. The sensitivity and specificity for detection of abnormal glands were 90% and 95%, respectively. False-positive or false-negative results were minimize by strict adherence to a protocol and by the use of well-defined diagnostic criteria. Because of the superior sensitivity and specificity, this modality should be the primary imaging method of choice for preoperative evaluation of primary hyperparathyroidism. The relative role of other imaging modalities is also discussed. 31 references

  17. Automatic 2D scintillation camera and computed tomography whole-body image registration to perform dosimetric calculations

    International Nuclear Information System (INIS)

    Cismondi, F.; Mosconi, S.L.

    2008-01-01

    Full text: In this work a software tool that has been developed to allow automatic registrations of 2D Scintillation Camera (SC) and Computed Tomography (CT) images is presented. This tool, used with a dosimetric software with Integrated Activity or Residence Time as input data, allows the user to assess physicians about effects of radiodiagnostic or radiotherapeutic practices that involves nuclear medicine 'open sources'. Images are registered locally and globally, maximizing Mutual Information coefficient between regions been registered. In the regional case whole-body images are segmented into five regions: head, thorax, pelvis, left and right legs. Each region has its own registration parameters, which are optimized through Powell-Brent minimization method that 'maximizes' Mutual Information coefficient. This software tool allows the user to draw ROIs, input isotope characteristics and finally calculate Integrated Activity or Residence Time in one or many specific organ. These last values can be introduced in many dosimetric software to finally obtain Absorbed Dose values. (author)

  18. Whole-body 35-GHz security scanner

    Science.gov (United States)

    Appleby, Roger; Anderton, Rupert N.; Price, Sean; Sinclair, Gordon N.; Coward, Peter R.

    2004-08-01

    A 35GHz imager designed for Security Scanning has been previously demonstrated. That imager was based on a folded conical scan technology and was constructed from low cost materials such as expanded polystyrene and printed circuit board. In conjunction with an illumination chamber it was used to collect indoor imagery of people with weapons and contraband hidden under their clothing. That imager had a spot size of 20mm and covered a field of view of 20 x 10 degrees that partially covered the body of an adult from knees to shoulders. A new variant of this imager has been designed and constructed. It has a field of view of 36 x 18 degrees and is capable of covering the whole body of an adult. This was achieved by increasing the number of direct detection receivers from the 32 used in the previous design to 58, and by implementing an improved optical design. The optics consist of a front grid, a polarisation device which converts linear to circular polarisation and a rotating scanner. This new design uses high-density expanded polystyrene as a correcting element on the back of the front grid. This gives an added degree of freedom that allows the optical design to be diffraction limited over a very wide field of view. Obscuration by the receivers and associated components is minimised by integrating the post detection electronics at the receiver array.

  19. Thallium scintigraphy during dobutamine infusion: nonexercise-dependent screening test for coronary disease

    International Nuclear Information System (INIS)

    Mason, J.R.; Palac, R.T.; Freeman, M.L.; Virupannavar, S.; Loeb, H.S.; Kaplan, E.; Gunnar, R.M.

    1984-01-01

    Exercise thallium scintigraphy has proven to be a sensitive method for detecting coronary artery disease (CAD). However, early redistribution of thallium and inadequate exercise can reduce its sensitivity. In this study, dobutamine was infused in incremental doses (5, 10, 15, and 20 micrograms/kg/min) in 24 patients being evaluated for chest pain. Thallium scintigraphy was completed during the maximum dose of dobutamine tolerated and repeated 4 hours later. Significant CAD was present in 16 patients; the remaining eight had normal coronaries. Exercise ECG was obtained in 23 patients. During dobutamine thallium scintigraphy, reversible perfusion defects occurred in 15 of 16 CAD and in one of eight non-CAD patients, resulting in a sensitivity of 94% and a specificity of 87%. Exercise ECG had a sensitivity of 60% and a specificity of 63%. We conclude that: (1) dobutamine thallium scintigraphy appears to be a sensitive method for detecting significant CAD and provided a more sensitive screening test than exercise ECG; (2) dobutamine thallium scintigraphy is especially useful in patients who cannot exercise; and (3) because imaging occurs during dobutamine infusion, the problem of early redistribution may be mitigated

  20. Whole body effective dose measurements in a fan beam bone mineral densitometer, Lunar expert

    Energy Technology Data Exchange (ETDEWEB)

    Sathiakumar, C.; Griffiths, M.; Cross, P.; Pocock, N.; Freund, J. [St Vincents Hospital, Sydney, NSW (Australia) Department of Nuclear Medicine; Kron, T.; Duggan, L. [Newcastle Mater Misericordiae Hospital, Newcastle, NSW (Australia). Department of Radiation Oncology; Holley, L. [University of Technology, Sydney, NSW (Australia). Department of Health Services

    1998-06-01

    Full text: The most recent generation of DXA machines employ a fan beam geometry and high resolution imaging detector, resulting in decreased scanning time and increased image resolution compared to previous rectilinear scanners, but with higher radiation burden to the patient because of an increasing number of bone mineral density scans, it was felt that independent evaluation of the radiation dose was necessary. The whole body effective dose for an AP lumbar spine scan and femur scan using the EXPERT bone densitometer was calculated for the fast and turbo scanning modes, using thermoluminescence dosimetry (TLD). A method was developed to determine the absorbed dose of the irradiated volume of an organ by summing the dose for each of the coronal areas, which results in a volume dose. The Whole Body Effective dose for AP lumbar spine fast scanning mode is 84.1 {mu}Sv and turbo scanning mode is 56.4 {mu}Sv. The Whole Body Effective dose for femur fast scanning mode is 6.6 {mu}Sv and turbo scanning mode is 4.2 {mu}Sv, with no ovary exposure. A theoretical method has been developed to calculate the organ dose from which whole body effective dose was calculated

  1. Value of whole body 123I scan for detection of metastasis in patients with well-differentiated thyroid carcinoma

    International Nuclear Information System (INIS)

    Takahashi, Naoya; Odano, Ikuo; Sugita, Tadashi; Sato, Yoko; Sakai, Kunio

    1995-01-01

    To evaluate the utility of 123 I whole body scan for detection of metastasis in patients with well-differentiated thyroid carcinoma, post-therapy whole body 131 I images in 55 cases were compared with pre-therapy 123 I images using diagnostic dose (74 MBq). The post-therapy studies were performed 7 days after administration of therapeutic doses (3.33-7.77 GBq) of 131 I. The pre-therapy scans showed 30 lesions (71.4%) of 42 lesions which were shown by 131 I post-therapy scans. The diagnostic accuracy of 123 I whole body scans was considered to be nearly the same as the images obtained by 131 I using diagnostic dose. 123 I has short-life and an optimum gamma ray energy for scintigraphy. It makes radiation dose to patients lower than that of 131 I. Therefore, we recommend pre-therapy 131 I image using diagnostic dose is replaced by 123 I image. (author)

  2. 3D whole body scanners revisited

    NARCIS (Netherlands)

    Daanen, H.A.M.; Haar, F.B. ter

    2013-01-01

    An overview of whole body scanners in 1998 (H.A.M. Daanen, G.J. Van De Water. Whole body scanners, Displays 19 (1998) 111-120) shortly after they emerged to the market revealed that the systems were bulky, slow, expensive and low in resolution. This update shows that new developments in sensing and

  3. Sodium bicarbonate-augmented stress thallium myocardial scintigraphy

    International Nuclear Information System (INIS)

    Sarin, Badal; Chugh, Pradeep Kumar; Kaushal, Dinesh; Soni, Nakse Lal; Sawroop, Kishan; Mondal, Anupam; Bhatnagar, Aseem

    2004-01-01

    It is well known that sodium bicarbonate in pharmacological doses induces transient alkalosis, causing intracellular transport of serum potassium. The aims of this study were (a) to investigate whether, in humans, myocardial thallium-201 uptake can be augmented by pretreatment with a single bolus of sodium bicarbonate at a pharmacological dose, (b) to verify general safety aspects of the intervention and (c) to evaluate the clinical implications of augmentation of 201 Tl uptake, if any. Routine exercise myocardial scintigraphy was performed twice in eight adult volunteers (five normal and three abnormal), once without intervention and the second time (within a week) following intravenous administration of sodium bicarbonate (88 mEq in 50 ml) as a slow bolus 1 h prior to the injection of 201 Tl. Conventional myocardial thallium study was compared with sodium bicarbonate interventional myocardial scintigraphy with respect to myocardial uptake (counts per minute per mCi injected dose), washout patterns in normal and abnormal myocardial segments, and overall clinical interpretation based on planar and single-photon emission tomographic (SPET) images. All patients remained asymptomatic after the intervention. A mean increase of 53% in myocardial uptake of thallium was noted in post-exercise acquisitions after the intervention, confirming uptake of the tracer via the potassium-hydrogen pump and its augmentation by transient alkalosis. The washout pattern remained unchanged. The visual quality of planar and SPET images improved significantly after the intervention. Out of the five abnormal myocardial segments identified in three cases, four showed significant filling-in after the intervention, causing the diagnosis to be upgraded from ''partial scar'' to ''ischaemia'', or from ''ischaemia'' to ''normal''. The overall scan impression changed in two out of three such cases. Sodium bicarbonate augmentation may have significant implications for stress-thallium scintigraphy

  4. Brain fluorodeoxyglucose positron emission tomography (¹⁸FDG PET) in patients with acute thallium intoxication.

    Science.gov (United States)

    Liu, C H; Lin, K J; Wang, H M; Kuo, H C; Chuang, W L; Weng, Y H; Shih, T S; Huang, C C

    2013-03-01

    Thallium toxicity induces cellular injury through impaired Na-K-ATPase activity. The aim of this study was to investigate functional imaging and the long-term clinical-imaging correlations of thallium toxicity. We measured thallium concentrations in blood, urine, stools, and hair of a 48-year-old woman and a 52-year-old man (patients 1 and 2) in the first 3 months after exposure to thallium containing water, and studied their neuropsychological functions. Using fluorodeoxyglucose positron emission tomography ((18)FDG PET) scans, we examined the brain involvement and correlated the image findings with the clinical presentations. On the 1st, 30th, and 61st days after exposure, the thallium concentrations in patient 1 were 2056, 311, and 7.5 μg/L in the blood, and 11400, 4570, and 36.4 μg/L in the urine. The concentrations in patient 2 were 956, 235, and 15.6 μg/L in the blood, and 11900, 2670, and 101 μg/L in the urine. On the 40th, 50th and 89th days after exposure, the thallium concentration in the stools were 21.6, 3.6, and 0.35 μg/g in patient 1, and 22.2, 3.2, and 0.37 μg/g in patient 2. Executive function, perceptual motor speed, and learning memory were initially abnormal but recovered particularly within the first year. The first (18)FDG PET studies of both patients disclosed a decreased uptake of glucose metabolism in the cingulate gyrus, bilateral frontal, and parietal lobes 2-5 months after exposure. The follow-up (18)FDG PET scan of patient 2 revealed a partial recovery. This study indicates that damage to the central nervous system after acute thallium poisoning may be reversible after a long-term follow-up. Brain (18)FDG PET demonstrated the brain involvement and was correlated with cognitive impairment.

  5. The usefulness of planar thallium myocardial perfusion imaging in the diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Johannesen, K.A.; Andersen, K.; Foelling, M.; Vik-Mo, H.

    1991-01-01

    Stress thallium scintigraphy was performed in 60 patients with chest pain of uncertain origin. Myocardial ischemia was identified in 91% og the 47 patients who had angiographically significant coronary artery stenosis. Sensitivity of thallium scintigraphy was highest in patients with stenosis in the left descending coronary artery (LAD); 91% of the patients had abnormal thallium as compared with 67% of the patients with normal LAD, but significant stenosis in the circumflex artery and/or the right coronary artery. Perfusion defects in the circumflex or right coronary artery regions were detected in only 50% of the patients with multiple vessel disease. The authors conclude that stress thallium scintigraphy is a useful diagnostic procedure in patients with chest pain of uncertain origin and identifies the patients to be selected for coronary artery angiography. 15 refs., 2 figs., 2 tabs

  6. Whole-Body MRI versus PET in assessment of multiple myeloma disease activity.

    LENUS (Irish Health Repository)

    Shortt, Conor P

    2009-04-01

    The purpose of this study was to compare FDG PET; whole-body MRI; and the reference standard, bone marrow aspiration and biopsy, to determine the best imaging technique for assessment of disease activity in multiple myeloma.

  7. Whole-body magnetic resonance imaging for staging and follow-up of pediatric patients with Hodgkin's lymphoma: comparison of different sequences

    International Nuclear Information System (INIS)

    Nava, Daniel; Oliveira, Heverton Cesar de

    2011-01-01

    Objective: to compare the performance of the T1, T2, STIR and DWIBS (diffusion-weighted whole-body imaging with background body signal suppression) sequences in the staging and follow-up of pediatric patients with Hodgkin's lymphoma in lymph node chains, parenchymal organs and bone marrow, and to evaluate interobserver agreement. Materials and methods: the authors studied 12 patients with confirmed diagnosis of Hodgkin's lymphoma. The patients were referred for whole body magnetic resonance imaging with T1-weighted, T2-weighted, STIR and DWIBS sequences. Results: the number of lymph node sites characterized as affected by the disease on T1- and T2-weighted sequences showed similar results (8 sites for both sequences), but lower than DWIBS and STIR sequences (11 and 12 sites, respectively). The bone marrow involvement by lymphoma showed the same values for the T1-, T2-weighted and DWIBS sequences (17 lesions), higher than the value found on STIR (13 lesions). A high rate of interobserver agreement was observed as the four sequences were analyzed. Conclusion: STIR and DWIBS sequences detected the highest number of lymph node sites characterized as affected by the disease. Similar results were demonstrated by all the sequences in the evaluation of parenchymal organs and bone marrow. A high interobserver agreement was observed as the four sequences were analyzed. (author)

  8. Neuropsychology of thallium poisoning

    Science.gov (United States)

    McMillan, T; Jacobson, R; Gross, M

    1997-01-01

    Cases of thallium poisoning are rare and neuropsychological assessment has only been reported in detail in one other case. In the case reported here, neuropsychological assessments were carried out three, 12, and 54 months after diagnosis of thallium poisoning in a man who had acutely shown a number of neurological signs including confusion and disorientation and generalised slowing of EEG which was more prominent on the left. Evidence suggested that he had been exposed to thallium over a period of weeks. Neuropsychological assessment indicated an unexpected weakness in verbal abilities which persisted. This finding is consistent with the only other published case report which details neuropsychological effects after a single large dose of thallium and which also found a lateralised impairment.

 PMID:9285467

  9. Thallium toxicity in humans.

    Science.gov (United States)

    Cvjetko, Petra; Cvjetko, Ivan; Pavlica, Mirjana

    2010-03-01

    Thallium is a naturally occurring trace element, widely distributed in the earth's crust, but at very low concentrations. It does not have a known biological use and does not appear to be an essential element for life. It has been considered one of the most toxic heavy metals.Occasionally, there are reports on thallium poisoning as results of suicide or murder attempt or accident. The main threat to humans is through occupational exposure, environmental contamination, and accumulation in food, mainly in vegetables grown on contaminated soil. Increasing use in emerging new technologies and demanding high-tech industry constantly raise concern about exposure risk to all living organisms. Thallium is considered a cumulative poison that can cause adverse health effects and degenerative changes in many organs. The effects are the most severe in the nervous system. The exact mechanism of thallium toxicity still remains unknown, although impaired glutathione metabolism, oxidative stress, and disruption of potassium-regulated homeostasis may play a role. The lack of data about mutagenic, carcinogenic, or teratogenic effects of thallium compounds in humans calls for further research.

  10. Colorectal cancer staging: comparison of whole-body PET/CT and PET/MR.

    Science.gov (United States)

    Catalano, Onofrio A; Coutinho, Artur M; Sahani, Dushyant V; Vangel, Mark G; Gee, Michael S; Hahn, Peter F; Witzel, Thomas; Soricelli, Andrea; Salvatore, Marco; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce R; Gervais, Debra

    2017-04-01

    Correct staging is imperative for colorectal cancer (CRC) since it influences both prognosis and management. Several imaging methods are used for this purpose, with variable performance. Positron emission tomography-magnetic resonance (PET/MR) is an innovative imaging technique recently employed for clinical application. The present study was undertaken to compare the staging accuracy of whole-body positron emission tomography-computed tomography (PET/CT) with whole-body PET/MR in patients with both newly diagnosed and treated colorectal cancer. Twenty-six patients, who underwent same day whole-body (WB) PET/CT and WB-PET/MR, were evaluated. PET/CT and PET/MR studies were interpreted by consensus by a radiologist and a nuclear medicine physician. Correlations with prior imaging and follow-up studies were used as the reference standard. Correct staging was compared between methods using McNemar's Chi square test. The two methods were in agreement and correct for 18/26 (69%) patients, and in agreement and incorrect for one patient (3.8%). PET/MR and PET/CT stages for the remaining 7/26 patients (27%) were discordant, with PET/MR staging being correct in all seven cases. PET/MR significantly outperformed PET/CT overall for accurate staging (P = 0.02). PET/MR outperformed PET/CT in CRC staging. PET/MR might allow accurate local and distant staging of CRC patients during both at the time of diagnosis and during follow-up.

  11. My Body Looks Like That Girl's: Body Mass Index Modulates Brain Activity during Body Image Self-Reflection among Young Women.

    Science.gov (United States)

    Gao, Xiao; Deng, Xiao; Wen, Xin; She, Ying; Vinke, Petra Corianne; Chen, Hong

    2016-01-01

    Body image distress or body dissatisfaction is one of the most common consequences of obesity and overweight. We investigated the neural bases of body image processing in overweight and average weight young women to understand whether brain regions that were previously found to be involved in processing self-reflective, perspective and affective components of body image would show different activation between two groups. Thirteen overweight (O-W group, age = 20.31±1.70 years) and thirteen average weight (A-W group, age = 20.15±1.62 years) young women underwent functional magnetic resonance imaging while performing a body image self-reflection task. Among both groups, whole-brain analysis revealed activations of a brain network related to perceptive and affective components of body image processing. ROI analysis showed a main effect of group in ACC as well as a group by condition interaction within bilateral EBA, bilateral FBA, right IPL, bilateral DLPFC, left amygdala and left MPFC. For the A-W group, simple effect analysis revealed stronger activations in Thin-Control compared to Fat-Control condition within regions related to perceptive (including bilateral EBA, bilateral FBA, right IPL) and affective components of body image processing (including bilateral DLPFC, left amygdala), as well as self-reference (left MPFC). The O-W group only showed stronger activations in Fat-Control than in Thin-Control condition within regions related to the perceptive component of body image processing (including left EBA and left FBA). Path analysis showed that in the Fat-Thin contrast, body dissatisfaction completely mediated the group difference in brain response in left amygdala across the whole sample. Our data are the first to demonstrate differences in brain response to body pictures between average weight and overweight young females involved in a body image self-reflection task. These results provide insights for understanding the vulnerability to body image distress

  12. Evaluation of [18F]Nifene biodistribution and dosimetry based on whole-body PET imaging of mice

    International Nuclear Information System (INIS)

    Constantinescu, Cristian C.; Garcia, Adriana; Mirbolooki, M. Reza; Pan, Min-Liang; Mukherjee, Jogeshwar

    2013-01-01

    Introduction: [ 18 F]Nifene is a novel radiotracer specific to the nicotinic acetylcholine α4β2 receptor class. In preparation for using this tracer in humans we have performed whole-body PET studies in mice to evaluate the in vivo biodistribution and dosimetry of [ 18 F]Nifene. Methods: Seven BALB/c mice (3 males, 4 females) received IV tail injections of [ 18 F]Nifene and were scanned for 2 h in an Inveon dedicated PET scanner. Each animal also received a high resolution CT scan using an Inveon CT. The CT images were used to draw volume of interest (VOI) on the following organs: brain, large intestine, small intestine, stomach, heart, kidneys, liver, lungs, pancreas, bone, spleen, testes, thymus, uterus and urinary bladder. All organ time activity curves had the decay correction reversed and were normalized to the injected activity. The area under the normalized curves was then used to compute the residence times in each organ. The absorbed doses in mouse organs were computed using the RAdiation Dose Assessment Resource (RADAR) animal models for dose assessment. The residence times in mouse organs were converted to human values using scale factors based on differences between organ and body weights. OLINDA 1.1 software was used to compute the absorbed human doses in multiple organs for both female and male phantoms. Results: The highest mouse residence times were found in urinary bladder, liver, bone, small intestine and kidneys. The largest doses in mice were found in urinary bladder and kidneys for both females and males. The elimination of radiotracer was primarily via kidney and urinary bladder with the urinary bladder being the limiting organ. The projected human effective doses were 1.51E-02 mSv/MBq for the adult male phantom and 1.65E-02 mSv/MBq for the adult female model phantom. Conclusion: This study indicates that the whole-body mouse imaging can be used as a preclinical tool for initial estimation of the absorbed doses of [ 18 F]Nifene in humans

  13. Computer-enhanced thallium scintigrams in asymptomatic men with abnormal exercise tests

    International Nuclear Information System (INIS)

    Uhl, G.S.; Kay, T.N.; Hickman, J.R. Jr.

    1981-01-01

    The use of treadmill testing in asymptomatic patients and those with an atypical chest pain syndrome is increasing, yet the proportion of false positive stress electrocardiograms increases as the prevalence of disease decreases. To determine the diagnostic accuracy of computer-enhanced thallium perfusion scintigraphy in this subgroup of patients, multigated thallium scans were obtained after peak exercise and 3 or 4 hours after exercise and the raw images enhanced by a computer before interpretations were made. The patient group consisted of 191 asymptomatic U.S. Air force aircrewmen who had an abnormal exercise electrocardiogram. Of these, 135 had normal coronary angiographic findings, 15 had subcritical coronary stenosis (less than 50 percent diameter narrowing) and 41 had significant coronary artery disease. Use of computer enhancement resulted in only four false positive and two false negative scintigrams. The small subgroup with subcritical coronary disease had equivocal results on thallium scintigraphy, 10 men having abnormal scans and 5 showing no defects. The clinical significance of such subcritical disease in unclear, but it can be detected with thallium scintigraphy. Thallium scintigrams that have been enhanced by readily available computer techniques are an accurate diagnostic tool even in asymptomatic patients with an easily interpretable abnormal maximal stress electrocardiogram. Thallium scans can be effectively used in counseling asymptomatic patients on the likelihood of their having coronary artery disease

  14. Whole Body MR Imaging Versus 99mTC-Methylene Diphosphonate Scintigraphy in Detection of Skeletal Metastases

    International Nuclear Information System (INIS)

    SALEM, H.T.M.

    2009-01-01

    The introduction of new chemotherapy protocols, which include both marrow and stem cell transplantation, has increased the demand for accurate and early detection of skeletal metastases, particularly metastases to marrow (Eustace et al., 1997). All existing methods of detection skeletal metastases have limitations. Metastases to bone only become apparent on radiographs after the loss of more than 50% of the bone mineral content at the site of the disease. Although CT allows earlier detection of cortical destruction by imaging in contiguous tomographic slices, its ability to detect early deposits in marrow is limited (Gold et al., 1990). The use of bone scintigraphy in the assessment of skeletal abnormalities is based on increased sensitivity in detecting abnormalities before other diagnostic imaging techniques. The pitfall of bone scintigraphy is its lack of specificity. There must be close correlation of scintigraphic findings with those of other imaging modalities (Nadel et al., 2001). The high spatial resolution and excellent soft-tissue contrast make MR imaging an ideal tool for the detection of osseous lesions. The limited field of view must be considered a major limitation of conventional MR imaging. Furthermore MR imaging approaches were limited by long acquisition times. Development in MR imaging, such as the development of turbo sequences, have led to renewed interest in MR imaging as a potential whole body screening tool (Johnson et al., 1997 and Lauenstein et al., 2004).

  15. Evaluation of radiation dose and image quality of CT scan for whole-body pediatric PET/CT: A phantom study

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Ching-Ching, E-mail: cyang@tccn.edu.tw [Department of Medical Imaging and Radiological Sciences, Tzu-Chi College of Technology, 970, Hualien, Taiwan (China); Liu, Shu-Hsin [Department of Nuclear Medicine, Buddhist Tzu-Chi General Hospital, 970, Hualien, Taiwan and Department of Medical Imaging and Radiological Sciences, Tzu-Chi College of Technology, 970, Hualien, Taiwan (China); Mok, Greta S. P. [Biomedical Imaging Laboratory, Department of Electrical and Computer Engineering, Faculty of Science and Technology, University of Macau, Macau (China); Wu, Tung-Hsin [Department of Biomedical Imaging and Radiological Sciences, National Yang-Ming University, 112, Taipei, Taiwan (China)

    2014-09-15

    Purpose: This study aimed to tailor the CT imaging protocols for pediatric patients undergoing whole-body PET/CT examinations with appropriate attention to radiation exposure while maintaining adequate image quality for anatomic delineation of PET findings and attenuation correction of PET emission data. Methods: The measurements were made by using three anthropomorphic phantoms representative of 1-, 5-, and 10-year-old children with tube voltages of 80, 100, and 120 kVp, tube currents of 10, 40, 80, and 120 mA, and exposure time of 0.5 s at 1.75:1 pitch. Radiation dose estimates were derived from the dose-length product and were used to calculate risk estimates for radiation-induced cancer. The influence of image noise on image contrast and attenuation map for CT scans were evaluated based on Pearson's correlation coefficient and covariance, respectively. Multiple linear regression methods were used to investigate the effects of patient age, tube voltage, and tube current on radiation-induced cancer risk and image noise for CT scans. Results: The effective dose obtained using three anthropomorphic phantoms and 12 combinations of kVp and mA ranged from 0.09 to 4.08 mSv. Based on our results, CT scans acquired with 80 kVp/60 mA, 80 kVp/80 mA, and 100 kVp/60 mA could be performed on 1-, 5-, and 10-year-old children, respectively, to minimize cancer risk due to CT scans while maintaining the accuracy of attenuation map and CT image contrast. The effective doses of the proposed protocols for 1-, 5- and 10-year-old children were 0.65, 0.86, and 1.065 mSv, respectively. Conclusions: Low-dose pediatric CT protocols were proposed to balance the tradeoff between radiation-induced cancer risk and image quality for patients ranging in age from 1 to 10 years old undergoing whole-body PET/CT examinations.

  16. In situ deposition of thallium-containing oxides

    International Nuclear Information System (INIS)

    Myers, K.E.

    1996-01-01

    The number and variety of thallium based materials that can be made by in situ methods have grown consistently since the first report of successful thallium cuprate deposition by Face and Nestlerode in 1992. Processes for the deposition of superconductors, normal metals, and insulators have been developed. Most work to date has been done on the Tl-1212 phases, TlBa 2 CaCu 2 O 7 and (Tl,Pb)Sr 2 CaCu 2 O 7 . Recently however, the in situ thallium technique has been extended to other materials. For example, epitaxial thin films of thallium tantalate, an insulator of the pyrochlore structure and a potential buffer layer for thallium cuprate films, have been grown. Multilayers, important in the fabrication of Josephson junctions, have been demonstrated with the thallium lead cuprates. This paper reviews progress in the area of in situ thallium deposition technology which will make more complex thallium cuprate multilayer structures and devices possible

  17. Development of 'Enhance reconstruction package' software for whole-body PET

    International Nuclear Information System (INIS)

    Mizuta, Tetsuro; Imanishi, Tatsuru; Ishikawa, Akihiro

    2011-01-01

    We have developed 'Enhance Reconstruction Package' Software for our whole-body positron emission tomography (PET) Eminence series. This package improves image quality and streamlines the workflow in clinical PET and PET/CT studies. The present paper describes an outline of the applications for data collection, normalization, etc. and also reports some PET images obtained by the software. The signal to noise ratio was optimized in the phantom study, leading to the improvement in image quality. The real time display tool and the remote control tool would make a contribution to enhancement in operability in the routine workflow. (author)

  18. Prognostic importance of thallium uptake by the lungs during exercise in coronary artery disease

    International Nuclear Information System (INIS)

    Gill, J.B.; Ruddy, T.D.; Newell, J.B.; Finkelstein, D.M.; Strauss, H.W.; Boucher, C.A.

    1987-01-01

    We studied the value of thallium imaging as compared with clinical and exercise-test variables in predicting cardiac events occurring over five years in 525 consecutive patients referred for thallium-exercise testing in 1979. Follow-up was obtained on 467 patients (89 percent). There were 105 cardiac events--25 cardiac deaths, 33 myocardial infarctions, and 47 coronary bypass procedures. A Cox survival analysis identified increased thallium uptake by the lungs, a marker of left ventricular dysfunction during exercise, as the best predictor of a cardiac event (relative risk ratio = 3.5; 95 percent confidence interval, 2.2 to 5.4). The next most powerful predictors were a history of typical angina, a previous myocardial infarction, and ST-segment depression during exercise (relative risk ratios = 2.1, 1.8, and 1.7, respectively). No combination of variables made up for the loss in prognostic power when the variable of increased thallium uptake by the lungs was removed from the model. Cardiac events occurred over five years in 10 (5 percent) of 192 patients with a normal thallium scan, 41 (25 percent) of 163 patients with an abnormal thallium scan but normal thallium activity in the lungs, and 54 (67 percent) of 81 patients with increased thallium uptake by the lungs (P less than 0.0001). We conclude that increased uptake of thallium by the lungs during exercise predicts a high risk of subsequent cardiac events

  19. Thallium-201 for myocardial imaging: appearance of the normal heart

    International Nuclear Information System (INIS)

    Cook, D.J.; Bailey, I.; Strauss, H.W.; Rouleau, J.; Wagner, H.N. Jr.; Pitt, B.

    1976-01-01

    Thallium-201 myocardial perfusion images were obtained from 13 healthy adults after tracer administration both at rest and at maximal stress. On the rest-injected scan, tracer was seen in left ventricular myocardium, liver, and spleen. In two subjects with resting tachycardia, the right ventricular myocardium was slightly visualized after tracer injection at rest. When tracer was administered at stress, the left ventricular activity was more nearly homogeneous and the left ventricle was better defined on the scan. The left-ventricle-to-lung-background activity ratio increased from 2.4 at rest to 3.4 at stress. The right ventricular myocardium was seen on the stress-injected scan. Phantom studies, performed to define the optimum position for visualization of lesions, showed that small lesions were best defined when seen either en face or in tangent. Scans should be performed at stress whenever possible and multiple views are essential

  20. Possibilities of whole-body MRI for investigating musculoskeletal diseases

    International Nuclear Information System (INIS)

    Lenk, S.; Claussen, C.D.; Schlemmer, H.P.; Fischer, S.; Koetter, I.

    2004-01-01

    This contribution outlines possibilities and limitations of whole-body MRI for investigating musculoskeletal diseases. Benefits and drawbacks of the novel whole-body MRI technology are discussed and a possible whole-body MRI sequence protocol for musculoskeletal examinations is proposed. Muscle, joint and bone diseases are discussed in which the application of whole-body MRI may be of advantage. Particularly, polymyositis, muscledystrophy, rheumatoid arthritis, spondylitis ancylosans, multiple trauma, skeletal metastases, multiple myeloma and malignant lymphoma are mentioned. Whole-body MRI opens new advantages for the examination of multifocal musculoskeletal diseases. The clinical benefit of this method for particular diseases has to be evaluated in further studies, however. (orig.) [de

  1. My Body Looks Like That Girl’s: Body Mass Index Modulates Brain Activity during Body Image Self-Reflection among Young Women

    Science.gov (United States)

    Wen, Xin; She, Ying; Vinke, Petra Corianne; Chen, Hong

    2016-01-01

    Body image distress or body dissatisfaction is one of the most common consequences of obesity and overweight. We investigated the neural bases of body image processing in overweight and average weight young women to understand whether brain regions that were previously found to be involved in processing self-reflective, perspective and affective components of body image would show different activation between two groups. Thirteen overweight (O-W group, age = 20.31±1.70 years) and thirteen average weight (A-W group, age = 20.15±1.62 years) young women underwent functional magnetic resonance imaging while performing a body image self-reflection task. Among both groups, whole-brain analysis revealed activations of a brain network related to perceptive and affective components of body image processing. ROI analysis showed a main effect of group in ACC as well as a group by condition interaction within bilateral EBA, bilateral FBA, right IPL, bilateral DLPFC, left amygdala and left MPFC. For the A-W group, simple effect analysis revealed stronger activations in Thin-Control compared to Fat-Control condition within regions related to perceptive (including bilateral EBA, bilateral FBA, right IPL) and affective components of body image processing (including bilateral DLPFC, left amygdala), as well as self-reference (left MPFC). The O-W group only showed stronger activations in Fat-Control than in Thin-Control condition within regions related to the perceptive component of body image processing (including left EBA and left FBA). Path analysis showed that in the Fat-Thin contrast, body dissatisfaction completely mediated the group difference in brain response in left amygdala across the whole sample. Our data are the first to demonstrate differences in brain response to body pictures between average weight and overweight young females involved in a body image self-reflection task. These results provide insights for understanding the vulnerability to body image distress

  2. Thallium intoxication. Case Report.

    Science.gov (United States)

    Sojáková, Michaela; Žigrai, Miroslav; Karaman, Andrej; Plačková, Silvia; Klepancová, Petra; Hrušovský, Štefan

    2015-01-01

    We report a rare case of serious voluntary intoxication by laboratory thallium monobromate combined with alcohol intake by a 24-years old man. The diagnosis of thallium intoxication was based on history, nonspecific but typical clinical symptoms including gastrointestinal complaints, painful polyneuropathy, alopecia, and confirmed by the finding of increased thallium concentration in the urine. The treatment, performed at the due time, consisted of decontamination of the stomach by irrigation, administration of active charcoal and Prussian blue, correction of water and mineral dysbalance, symptomatic treatment, and led to complete recovery.

  3. Value of 201-thallium serial myocardial imaging in coronary heart disease

    International Nuclear Information System (INIS)

    Sauer, E.; Sebening, H.; Dressler, J.; Lutilsky, L.; Ulm, K.; Hoer, G.; Papst, H.W.; Bloemer, H.; Technische Univ. Muenchen; Technische Univ. Muenchen

    1979-01-01

    There has been clinical evidence that a perfusion defect on a stress image fills overtime. The diagnostic value of initial and 120 min post exercise redistribution thallium-201 myocardial images (RMI) was determined in 120 pts, with suspected coronary heart disease (CAD), all of whom had coronary arteriography. Significant (>= 75%) lesions were present in 88 pts. 30 pts. without CAD showed a normal tracer uptake immediately after exercise. Scintigrams taken 120 min after exercise revealed a decrease of 201-Tl concentration in every area of the myocardium. 80 pts. with CAD showed an area of decreased tracer uptake in the inital scans. 120 min RMI in 51 pts. revealed a significant increase (p > 0.01) of countrate time ratio in previous underperfused areas. In 37 pts. persistent defects were present, in every case the defect correlated with the site of a myocardial infarction as determined by the finding of an akinetic area in the left ventricular angiogram. Thus RMI following a single dose of 201 Tl can differentiate between scar- and exercise-induced transient ischemia. (orig.) 891 AJ/orig. 892 MB [de

  4. Contribution to the study of thallium 201 myocardium scintigraphy

    International Nuclear Information System (INIS)

    Annweiler, Marc.

    1976-01-01

    In this work a new isotope was tested in the field of myocardium scintigraphy: thallium 201. The different radioisotopes used so far in myocardium scintigraphy are reviewed to begin with. The main biological and physical characteristics of thallium and the scintillation camera used for this work are described next. In our opinion thallium 201 owing to its biological behavior similar to that of potassium and to its physical characteristics, appears as one of the better -if not the best- known tracer suitable for use in myocardium scintigraphy. Its properties are suited to the use of a scintillation camera, which considerably shortens the examination time and thus allows an isotopic exploration of the myocardium from several incidences. The only disadvantage of this cyclotron-produced isotope seems to be its high price which will probably limit its use on a large scale. Fifty thallium 201 myocardium scintigraphs were practised on forty-eight coronary thrombosis patients. From this was established a precise topographic correlation between the electrocardiographic diagnosis and the scintigraph. The two corresponded in 47 cases out of 50. The few disagreements between ECG and scintigraphic results seem to be due either to poor-quality images or to an overall myocardium hypofixation connected with a very extensive necrosis. This means that thallium 201 myocardium scintigraphy is a reliable method of examination in the great majority of cases, giving a direct picture of the heart muscle and its necrotic lesions [fr

  5. Method of quantification of bone scintigraphy using technetium labelled stannous pyrophosphate. Results concerning 882 whole-body scintigraphy

    International Nuclear Information System (INIS)

    Chedeville, Rene.

    1976-01-01

    Considerable progress was made in isotope bone imaging with strontium 85 after the principle of quantification was introduced by Rosenthall in 1965. In 1971, Subramanian and McAffee reported that excellent visualization could be obtained with polyphosphates labelled with sup(99m)Tc. In the present study, imaging was performed 4 hours after injection of sup(99m)Tc pyrophosphate. An Elscint dual head wole body scanner and a VDP 2 off-line calculator were used. Counts were collected over selected regions of interest, each measuring 4.5 x 3.5 cm, and over the whole body. After checking reproducibility by double counting (SD of the mean = 15%), two methods of quantification were studied, the counts being expressed as: the ratio of the number of counts in the bone segment to the number of counts in the knee, the ratio of the number of counts in the bone segment/the number of counts in the whole body. In these operations, the whole body count was multiplied by 2.10 -3 in order to have a ratio whole body count.2.10 -3 /knee = 1. The ratios calculated from the different bone diseases under study were then compared [fr

  6. Radionuclide-determined changes in pulmonary blood volume and thallium lung uptake in patients with coronary artery disease

    International Nuclear Information System (INIS)

    Wilson, R.A.; Okada, R.D.; Boucher, C.A.; Strauss, H.W.; Pohost, G.M.

    1983-01-01

    Exercise-induced increases in radionuclide-determined pulmonary blood volume (PBV) and thallium lung uptake have been described in patients with coronary artery disease (CAD) and have been shown to correlate with transient exercise-induced left ventricular dysfunction. To compare these 2 techniques in the same patients, 74 patients (59 with and 15 without significant CAD) underwent supine bicycle exercise twice on the same day--first for thallium myocardial and lung imaging and then for technetium-99m gated blood pool imaging for the PBV ratio determination. Thallium activity of lung and myocardium was determined to calculate thallium lung/heart ratio. Relative changes in PBV from rest to exercise were expressed as a ratio of pulmonary counts (exercise/rest). Previously reported normal ranges for thallium lung/heart ratio and PBV ratio were used. The PBV ratio and thallium lung/heart ratio were abnormal in 71 and 36%, respectively, of patients with CAD (p less than 0.01). Both ratios were normal in all patients without CAD. Although the resting ejection fractions did not differ significantly in patients with normal versus those with abnormal PBV ratios or thallium lung/heart ratios, abnormal PBV ratios and thallium lung/heart ratios were associated with an exercise-induced decrease in ejection fraction. Propranolol use was significantly higher in patients with abnormal than in those with normal thallium lung/heart ratios (p less than 0.01). No significant difference in propranolol use was present in patients with abnormal or normal PBV ratios. In conclusion: (1) the prevalence of an abnormal thallium lung/heart ratio is less than that of the PBV ratio in patients with CAD; (2) both tests are normal in normal control subjects; (3) propranolol does not cause abnormal results in normal control subjects; however, propranolol may influence lung thallium uptake in patients with CAD; and (4) when both tests are abnormal, there is a high likelihood of multivessel disease

  7. Studies about the stress transaxial myocardium tomography with thallium -201

    International Nuclear Information System (INIS)

    Rocha Pantoja, M. da.

    1987-01-01

    Since the time of earliest applications of SPECT technology to Thallium-201 myocardial perfusion imaging, there has been no agreement as to what constitutes the best procedures to follow in order to achieve the theoretical advantages of SPECT to diagnose coronary artery disease. The purpose of these studies are to show the results of experimental and clinical investigations, that, have helped to resolve most of some controversies. Myocardial perfusion SPECT with Thallium-201 is clinically useful procedure that is readily applicable for routine clinical application provided correct techniques are utilized. (author)

  8. A prospective study comparing whole-body skeletal X-ray survey with 18F-FDG-PET/CT, 18F-NaF-PET/CT and whole-body MRI in the detection of bone lesions in multiple myeloma patients

    DEFF Research Database (Denmark)

    Dyrberg, Eva; Hendel, Helle W; Al-Farra, Gina

    2017-01-01

    Background: For decades, the most widely used imaging technique for myeloma bone lesions has been a whole-body skeletal X-ray survey (WBXR), but newer promising imaging techniques are evolving. Purpose: To compare WBXR with the advanced imaging techniques 18F-fluorodeoxyglucose (FDG) positron emi...

  9. Myocardial scintigraphy with thallium-201

    International Nuclear Information System (INIS)

    Schwaiger, M.; Silber, S.; Klein, U.; Rudolph, W.

    1980-01-01

    Thallium-201 myocardial scintigraphy is an important non-invasive method for assessment of coronary artery disease. Other applications of the method such as delineation of the right ventricular free wall in right ventricular overload, or the detection of hypertrophic cardiomyopathies or myocardial infiltrations are of subordinate importance. In heart disease such as congestive cardiomyopathy and mitral valve prolapse thallium-201 uptake defects have been described, the clinical implications of these findings, however, cannot be adequately interpreted at this time. Myocardial uptake of thallium-201 is an active process, dependent on and proportional to perfusion. Differentiation between myocardial ischemia and myocardial scar is based on the presence or absence of thallium-201 'redistribution'. That is, in the presence of acute reversible ischemia there is increased thallium-201 uptake in the post-ischemic phase in previously hypoperfused myocardium and, subsequently, equilibrium of the initially registered activity differences. 'Redistribution' has also been described in the resting scintigram of patients with severe coronary artery disease and chronic hypoperfusion. (orig.) [de

  10. Quantitative thallium-201 myocardial exercise scintigraphy in normal subjects and patients with normal coronary arteries

    International Nuclear Information System (INIS)

    Niemeyer, M.G.; St. Antonius Hospital Nieuwegein; Laarman, G.J.; Lelbach, S.; Cramer, M.J.; Ascoop, C.A.P.L.; Verzijlbergen, J.F.; Wall, E.E. van der; Zwinderman, A.H.; Pauwels, E.K.J.

    1990-01-01

    Quantitative thallium-201 myocardial exercise scintigraphy was tested in two patient populations representing alternative standards for cardiac normality: group I comprised 18 male uncatherized patients with a low likelihood of coronary artery disease (CAD); group II contained 41 patients with normal coronary arteriograms. Group I patients were younger, they achieved a higher rate-pressure product than group II patients; all had normal findings by phisical examination and electrocardiography at rest and exercise. Group II patients comprised 21 females, 11 patients showed abnormal electrocardiography at rest, and five patients showed ischemic ST depression during exercise. Twelve patients had sign of minimal CAD. Twelve patients revealed abnormal visual and quantitative thallium findings, three of these patients had minimal CAD. Profiles of uptake and washout of thallium-201 were derived from both patient groups, and compared with normal limits developed by Maddahi et al. Furthermore, low likelihood and angiographically normal patients may differ substantially, and both sets of normal patients should be considered when establishing criteria of abnormality in exercise thallium imaging. When commercial software containing normal limits for quantitative analysis of exercise thallium-201 imaging is used in clinical practice, it is mandatory to compare these with normal limits of uptake and washout of thallium-201, derived from the less heterogeneous group of low-likelihood subjects, which should be used in selecting a normal population to define normality. (author). 37 refs.; 3 figs; 1 tab

  11. Whole-body MR imaging in children with suspected osteonecrosis after intensive chemotherapy: preliminary results; Ganzkoerper-MRT bei Kindern mit Verdacht auf Osteonekrose nach intensiver Chemotherapie: Erste Ergebnisse

    Energy Technology Data Exchange (ETDEWEB)

    Beer, M.; Stenzel, M.; Darge, K. [Universitaetsklinikum Wuerzburg (Germany). Inst. fuer Roentgendiagnostik; Girschick, H.; Schlegel, P.G. [Universitaetsklinikum Wuerzburg (Germany). Kinderklinik

    2008-03-15

    Purpose: use of multidrug chemotherapy poses the risk of avascular osseous necroses in children. Depiction of the whole body, including clinically non-apparent sites is mandatory for starting early and proper treatment, including surgical approaches in lesions near the joints. We analyzed the value of whole-body MRI in the detection of osteonecrosis, (1) in relation to conventional X-ray imaging and clinical symptoms, (2) using different MRI sequences, (3) with follow-up examinations. Materials and methods: 5 patients suffering from an oncological disease, 13 to 16 years old (3 x ALL, 1 x medulloblastoma, 1 x CML), and recently developing bone pain were examined with X-ray imaging of the particular region and a whole-body MRI (T2w TIRM, T1w TSE sequences, pre- and post-contrast GD-DTPA, including fat suppression techniques). Neck/thorax/abdomen/pelvis, and upper and lower extremities were acquired in the coronal plane, and the feet in sagittal orientation. 4 of 5 patients had at least one follow-up examination (in the mean after 10 {+-} 4 months). Results: none of the initial X-ray images revealed an abnormal finding. The whole-body MRI showed in 4 of 5 children bone marrow lesions compatible with osteonecrosis. The locations were around the knee joints (n = 3) and the tibiae/ankle joints (n = 4). In addition to the symptomatic sites, MRI revealed additional lesions at the following sites: humerus (n = 5), hip joints (n = 4), knee joints (n = 6), ankle joints (n = 4). The size varied from small focal lesions to lesions measuring 90% of the whole transverse diameter of the bone. The lesions were able to be detected most easily with heavily T2-weighted (TIRM) sequences, and the diagnosis was most easily established using the non-enhanced TSE T1-weighted sequences. As a consequence of the results of the whole-body MRI, all patients with lesions compatible with osteonecrosis received symptomatic (n = 2) or specific (n = 2) therapy. In the follow-up examinations, a

  12. Superconducting thallium cuprates obtained by substitution of copper for thallium in the double-thallium layer cuprate (Tl2212)

    International Nuclear Information System (INIS)

    Gopalakrishnan, J.; Shivakumara, C.; Manivannan, V.

    1994-01-01

    A new series of superconducting thallium cuprates of nominal composition, (Tl 2-x Cu x )Ba 2 CaCu 2 O 8 (0 c s in the range 110--99K. The phases are metastable, decomposing at higher temperatures (∼1,150K) to a mixture of thallium cuprates, CuO and BaCuO 2 . Significantly, x=1 member decomposes at 1,150K to mixture of Tl2223, CuO and BaCuO 2 . Chemical titrations involving oxidation of bromide ions reveals that the copper substituting for thallium in (Tl 2-x Cu x )Ba 2 CaCu 2 O 8 most likely occurs in the III oxidation state for x≤0.25 and in a mixed state (II,III) state for x>0.25

  13. A model to predict multivessel coronary artery disease from the exercise thallium-201 stress test

    International Nuclear Information System (INIS)

    Pollock, S.G.; Abbott, R.D.; Boucher, C.A.; Watson, D.D.; Kaul, S.

    1991-01-01

    The aim of this study was to (1) determine whether nonimaging variables add to the diagnostic information available from exercise thallium-201 images for the detection of multivessel coronary artery disease; and (2) to develop a model based on the exercise thallium-201 stress test to predict the presence of multivessel disease. The study populations included 383 patients referred to the University of Virginia and 325 patients referred to the Massachusetts General Hospital for evaluation of chest pain. All patients underwent both cardiac catheterization and exercise thallium-201 stress testing between 1978 and 1981. In the University of Virginia cohort, at each level of thallium-201 abnormality (no defects, one defect, more than one defect), ST depression and patient age added significantly in the detection of multivessel disease. Logistic regression analysis using data from these patients identified three independent predictors of multivessel disease: initial thallium-201 defects, ST depression, and age. A model was developed to predict multivessel disease based on these variables. As might be expected, the risk of multivessel disease predicted by the model was similar to that actually observed in the University of Virginia population. More importantly, however, the model was accurate in predicting the occurrence of multivessel disease in the unrelated population studied at the Massachusetts General Hospital. It is, therefore, concluded that (1) nonimaging variables (age and exercise-induced ST depression) add independent information to thallium-201 imaging data in the detection of multivessel disease; and (2) a model has been developed based on the exercise thallium-201 stress test that can accurately predict the probability of multivessel disease in other populations

  14. Thallium-201 myocardial imaging for evaluation of pulmonary hypertension

    International Nuclear Information System (INIS)

    Ikuno, Yoshiyasu

    1979-01-01

    Thallium-201 ( 201 Tl) myocardial scintigraphy (TMS) was performed in 54 patients. The images were analysed semi-quantitatively by measuring the extent of radioisotope concentration in the right ventricular free wall and the size of the right ventricular cavity. The extent of radioisotope concentration (four degrees) was expressed as the right ventricular activity score (RVAS) and the size of the right ventricular cavity (three degrees) was expressed as the right ventricular cavity score (RVCS). The scores were added for a right ventricular total score (RVTS). To establish criteria for the diagnosis of pulmonary hypertension (PH) by means of TMS, these scores were compared with the values of pulmonary arterial mean pressure (PAMP). The criteria were evaluated by comparing them with conventional criteria for electrocardiographic diagnosis of right ventricular hypertrophy. Patients with a 2-point RVAS had a significantly higher PAMP than those with a 0 or 1-point RVAS (p 201 Tl myocardial scintigrams is a useful non-invasive method for evaluating PH and its severity. (J.P.N.)

  15. Sensitivity of thallium scintigraphy in the detection of individual coronary artery disease

    International Nuclear Information System (INIS)

    Khan, A.; Rehman, A.; Wiqar, M.A.; Khan, Z.A.; Ahmad, S.A.

    1988-01-01

    In this study we randomly selected 45 patients whose coronary angiograms were abnormals i.e. showing triple, double and single vessel disease. Out of 80 patients who had undergone stress thallium imaging and coronary angiography during the one year. Majority of these patients were males and their ages ranged between 34-54 years. Fifteen patients had suffered inferior myocardial infraction and 5 had sustained anterior myocardial infraction in the fast. We analysed their coronary angiograms and compared them with the scintigraphic findings. It is concluded that although thallium scanning has high sensitivity for detection of coronary artery disease in general, it has only moderate sensitivity for detection of stenosis in individual coronary arteries. In this study thallium scan identified 75% of RCA lesions, 66% of LAD lesions and 38% circumflex lesions. Thallium scan sometimes fails to identify the less serve lesions in presence of more severe coronary lesions in the some patients. The sensitivity is much higher in single vessel coronary artery disease. (author)

  16. Diagnostic imaging in polytrauma: comparison of radiation exposure from whole-body MSCT and conventional radiography with organ-specific CT

    International Nuclear Information System (INIS)

    Wedegaertner, U.; Lorenzen, M.; Weber, C.; Adam, G.; Nagel, H.D.

    2004-01-01

    Purpose: To compare the radiation dose of whole-body multislice CT (MSCT) and conventional radiography with organ-specific CT in polytrauma. Materials and Methods: The whole-body MSCT encompassing brain, neck and midface, chest, abdomen and pelvis was performed on a Somatom Volume Zoom (Siemens). Conventional radiography consisted of chest and cervical, thoracic and lumbar spine in two views as well as pelvis. Polymat, Siemens. Three combinations of organ specific CT were chosen: CT examination of (1) head and cervical spine, (2) head, cervical spine and chest, (3) head, cervical spine and abdomen. The effective doses of whole-body MSCT and conventional radiography with organ-specific CT were calculated. Results: Effective doses were 20 mSv for whole-body MSCT, 2 mSv for conventional x-ray, and 5 mSv for combination (1), 8 mSv for combination (2) and (3) 16 mSv for combination (3) of the organ-specific CT. The ratio of radiation dose between whole-body MSCT and radiography was 10: 1. This ratio was reduced to 3: 1, 2: 1 and 1: 1 when a combination of radiography and CT was performed. Conclusions: Whole-body MSCT in polytrauma compared to conventional radiography with organ-specific CT induces a threefold increased dose in unfavorable situations and no increased dose in favorable situations. Nevertheless, routine use of whole-body MSCT should be critically evaluated and should be adapted to the clinical benefit. (orig.) [de

  17. Study on the treatment of acute thallium poisoning.

    Science.gov (United States)

    Zhang, Hong-Tao; Qiao, Bao-Ping; Liu, Bao-Ping; Zhao, Xian-Guo

    2014-05-01

    Acute thallium poisoning rarely occurs but is a serious and even fatal medical condition. Currently, patients with acute thallium poisoning are usually treated with Prussian blue and blood purification therapy. However, there are few studies about these treatments for acute thallium poisoning. Nine patients with acute thallium poisoning from 1 family were treated successfully with Prussian blue and different types of blood purification therapies and analyzed. Prussian blue combined with sequential hemodialysis, hemoperfusion and/or continuous veno-venous hemofiltration were effective for the treatment of patients with acute thallium poisoning, even after delayed diagnosis. Blood purification therapies help in the clearance of thallium in those with acute thallium poisoning. Prussian blue treatment may do the benefit during this process.

  18. Quantitative whole body scintigraphy - a simplified approach

    International Nuclear Information System (INIS)

    Marienhagen, J.; Maenner, P.; Bock, E.; Schoenberger, J.; Eilles, C.

    1996-01-01

    In this paper we present investigations on a simplified method of quantitative whole body scintigraphy by using a dual head LFOV-gamma camera and a calibration algorithm without the need of additional attenuation or scatter correction. Validation of this approach to the anthropomorphic phantom as well as in patient studies showed a high accuracy concerning quantification of whole body activity (102.8% and 97.72%, resp.), by contrast organ activities were recovered with an error range up to 12%. The described method can be easily performed using commercially available software packages and is recommendable especially for quantitative whole body scintigraphy in a clinical setting. (orig.) [de

  19. Basic study of entire whole-body PET scanners based on the OpenPET geometry

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, Eiji, E-mail: rush@nirs.go.j [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan); Yamaya, Taiga; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo [National Institute of Radiological Sciences, 4-9-1 Inage-ku, Chiba 263-8555 (Japan)

    2010-09-21

    A conventional PET scanner has a 15-25 cm axial field-of-view (FOV) and images a whole body using about six bed positions. An OpenPET geometry can extend the axial FOV with a limited number of detectors. The entire whole-body PET scanner must be able to process a large amount of data effectively. In this work, we study feasibility of the fully 3D entire whole-body PET scanner using the GATE simulation. The OpenPET has 12 block detector rings with the ring diameter of 840 mm and each block detector ring consists of 48 depth-of-interaction (DOI) detectors. The OpenPET has the axial length of 895.95 mm with five parts of 58.95 mm open gaps. The OpenPET has higher single data loss than a conventional PET scanner at grouping circuits. NECR of the OpenPET decreases by single data loss. But single data loss is mitigated by separating the axially arranged detector into two parts. Also, multiple coincidences are found to be important for the entire whole-body PET scanner. The entire whole-body PET scanner with the OpenPET geometry promises to provide a large axial FOV with the open space and to have sufficient performance values. But single data loss at the grouping circuits and multiple coincidences are limited to the peak noise equivalent count rate (NECR) for the entire whole-body PET scanner.

  20. Radiation dosimetry of N-([{sup 11}C]methyl)benperidol as determined by whole-body PET imaging of primates

    Energy Technology Data Exchange (ETDEWEB)

    Antenor-Dorsey, Jo A.V. [Washington University School of Medicine, Department of Anatomy and Neurobiology, St. Louis, MO (United States); Laforest, Richard; Moerlein, Stephen M. [Washington University School of Medicine, Department of Radiology, St. Louis, MO (United States); Videen, Tom O. [Washington University School of Medicine, Department of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurology, St. Louis, MO (United States); Perlmutter, Joel S. [Washington University School of Medicine, Department of Anatomy and Neurobiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Radiology, St. Louis, MO (United States); Washington University School of Medicine, Department of Neurology, St. Louis, MO (United States); Washington University School of Medicine, Program in Physical Therapy, St. Louis, MO (United States)

    2008-04-15

    N-([{sup 11}C]methyl)benperidol ([{sup 11}C]NMB) can be used for positron emission tomography (PET) measurements of D{sub 2}-like dopamine receptor binding in vivo. We report the absorbed radiation dosimetry of i.v.-administered {sup 11}C-NMB, a critical step before applying this radioligand to imaging studies in humans. Whole-body PET imaging with a CTI/Siemens ECAT 953B scanner was done in a male and a female baboon. After i.v. injection of 444-1221 MBq of {sup 11}C-NMB, sequential images taken from the head to the pelvis were collected for 3 h. Volumes of interest (VOIs) were identified that entirely encompassed small organs (whole brain, striatum, eyes, and myocardium). Large organs (liver, lungs, kidneys, lower large intestine, and urinary bladder) were sampled by drawing representative regions within the organ volume. Time-activity curves for each VOI were extracted from the PET, and organ residence times were calculated by analytical integration of a multi-exponential fit of the time-activity curves. Human radiation doses were estimated using OLINDA/EXM 1.0 and the standard human model. Highest retention was observed in the blood and liver, each with total residence times of 1.5 min. The highest absorbed radiation doses were to the heart (10.5 mGy/kBq) and kidney (9.19 mGy/kBq), making these the critical organs for [{sup 11}C]NMB. A heart absorption of 50 mGy would result from an injected dose of 4,762 MBq [{sup 11}C]NMB. Thus, this study suggests that up to 4,762 MBq of [{sup 11}C]NMB can be safely administered to human subjects for PET studies. Total body dose and effective dose for [{sup 11}C]NMB are 2.82 mGy/kBq and 3.7 mSv/kBq, respectively. (orig.)

  1. Computer-enhanced thallium scintigrams in asymptomatic men with abnormal exercise tests

    International Nuclear Information System (INIS)

    Uhl, G.S.; Kay, T.N.; Hickman, J.R. Jr.

    1981-01-01

    The usefulness of computer-enhanced thallium-201 myocardial perfusion scintigraphy in excluding the diagnosis of coronary artery disease in asymptomatic patients showing abnormal exercise electrocardiograms is evaluated. Multigated thallium scans were obtained immediately following and 3 or 4 hours after maximal exercise testing in 191 consecutive asymptomatic Air Force aircrew members who had shown abnormal exercise electrocardiograms and who were due to undergo coronary angiography. Computer enhancement of the raw images is found to lead to four false positive and two false negative scintigrams as revealed by angiographic results, while the group of 15 with subcritical coronary disease exhibited equivocal results. Results reveal that enhanced thallium scintigrams are an accurate diagnostics tool in detecting myocardial ischemia in asymptomatic patients and may be used in counseling asymptomatic patients on their likelihood of having coronary artery disease

  2. A 4-Tesla superconducting whole-body magnet for MR imaging and spectroscopy

    International Nuclear Information System (INIS)

    Vetter, J.; Ries, G.; Reichert, T.

    1988-01-01

    Since January 87 a 4 tesla MR magnet with a 1.25 m diameter warm bore is in operation at the Siemens Research Laboratories. The magnet weighing 10 tons is part of a whole-body MR device devoted to in-vivo research studies at magnetic fields significantly higher than 2 tesla; the highest field strength presently used in standard MR whole-body systems. The stored energy of the adiabatically stable six-coil system is 39 MJ at 4 tesla. The rated current is 376 A. Superconducting and resistive shim-coils together with iron shims reduce the bare magnet inhomogeneity of 100 ppm down to less than 5 ppm in a 50 cm diameter spherical volume. The magnet operates in persistent mode with the current leads retracted. The field drift is less than 3 x 10/sup -8//h. A small helium refrigerator is used to cool both the two radiation shields of the cryostat and the current leads and to reliquify the evaporating helium gas. Results of coil design, analysis of forces and stresses, quench protection, cryostat design and magnet operation are reported

  3. Sodium bicarbonate-augmented stress thallium myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sarin, Badal; Chugh, Pradeep Kumar; Kaushal, Dinesh; Soni, Nakse Lal; Sawroop, Kishan; Mondal, Anupam; Bhatnagar, Aseem [Department of Nuclear Medicine, Institute of Nuclear Medicine and Allied Sciences, Brig. S. K. Mazumdar Road, 110054, Delhi (India)

    2004-04-01

    It is well known that sodium bicarbonate in pharmacological doses induces transient alkalosis, causing intracellular transport of serum potassium. The aims of this study were (a) to investigate whether, in humans, myocardial thallium-201 uptake can be augmented by pretreatment with a single bolus of sodium bicarbonate at a pharmacological dose, (b) to verify general safety aspects of the intervention and (c) to evaluate the clinical implications of augmentation of {sup 201}Tl uptake, if any. Routine exercise myocardial scintigraphy was performed twice in eight adult volunteers (five normal and three abnormal), once without intervention and the second time (within a week) following intravenous administration of sodium bicarbonate (88 mEq in 50 ml) as a slow bolus 1 h prior to the injection of {sup 201}Tl. Conventional myocardial thallium study was compared with sodium bicarbonate interventional myocardial scintigraphy with respect to myocardial uptake (counts per minute per mCi injected dose), washout patterns in normal and abnormal myocardial segments, and overall clinical interpretation based on planar and single-photon emission tomographic (SPET) images. All patients remained asymptomatic after the intervention. A mean increase of 53% in myocardial uptake of thallium was noted in post-exercise acquisitions after the intervention, confirming uptake of the tracer via the potassium-hydrogen pump and its augmentation by transient alkalosis. The washout pattern remained unchanged. The visual quality of planar and SPET images improved significantly after the intervention. Out of the five abnormal myocardial segments identified in three cases, four showed significant filling-in after the intervention, causing the diagnosis to be upgraded from ''partial scar'' to ''ischaemia'', or from ''ischaemia'' to ''normal''. The overall scan impression changed in two out of three such cases. Sodium

  4. Myocardial imaging by direct injection of thallium-201 into coronary artery

    International Nuclear Information System (INIS)

    Sugihara, Hiroki; Inagaki, Suetsugu; Kubota, Yasushi

    1988-01-01

    Myocardial perfusion images were evaluated by direct injection of Thallium (Tl)-201 into coronary artery. Approximately 0.5 - 1 mCi of Tl-201 were instilled into the right coronary artery and/or the left coronary artery after coronary arteriography. Three images were obtained in the anterior, left anterior oblique and left lateral projections. Myocardial perfusion images of single photon emission computed tomography were also acquired in some patients. An image of supreme quality could be obtained in spite of small dose of Tl-201 since there was a lack of interference from background activity. Myocardial perfusion images corresponded to areas which were supplied by left or right coronary artery respectively. And the regional myocardial blood flow distribution of a coronary artery bypass graft could be revealed by instilling Tl-201 into the graft. Further, contribution of collateral channels to myocardial perfusion was showed. Not only left ventricle but also right ventricle was clearly visualized by injection of Tl-201 into right coronary artery. But in a case with arrhythmogenic right ventricular dysplasia, there was an area of decreased tracer uptake in the apex of the right ventricle which was identified as the site of dysplasia by electrophysiologic study. We conclude that direct injection of Tl-201 into coronary artery is an useful method to clarify the correlation between coronary anatomical findings and coronary perfusion and contribution of collaterals to myocardial perfusion, and also to detect the right ventricular myopathic site. (author)

  5. Whole-body voxel phantoms of paediatric patients—UF Series B

    Science.gov (United States)

    Lee, Choonik; Lee, Choonsik; Williams, Jonathan L.; Bolch, Wesley E.

    2006-09-01

    Following the previous development of the head and torso voxel phantoms of paediatric patients for use in medical radiation protection (UF Series A), a set of whole-body voxel phantoms of paediatric patients (9-month male, 4-year female, 8-year female, 11-year male and 14-year male) has been developed through the attachment of arms and legs from segmented CT images of a healthy Korean adult (UF Series B). Even though partial-body phantoms (head-torso) may be used in a variety of medical dose reconstruction studies where the extremities are out-of-field or receive only very low levels of scatter radiation, whole-body phantoms play important roles in general radiation protection and in nuclear medicine dosimetry. Inclusion of the arms and legs is critical for dosimetry studies of paediatric patients due to the presence of active bone marrow within the extremities of children. While the UF Series A phantoms preserved the body dimensions and organ masses as seen in the original patients who were scanned, comprehensive adjustments were made for the Series B phantoms to better match International Commission on Radiological Protection (ICRP) age-interpolated reference body masses, body heights, sitting heights and internal organ masses. The CT images of arms and legs of a Korean adult were digitally rescaled and attached to each phantom of the UF series. After completion, the resolutions of the phantoms for the 9-month, 4-year, 8-year, 11-year and 14-year were set at 0.86 mm × 0.86 mm × 3.0 mm, 0.90 mm × 0.90 mm × 5.0 mm, 1.16 mm × 1.16 mm × 6.0 mm, 0.94 mm × 0.94 mm × 6.00 mm and 1.18 mm × 1.18 mm × 6.72 mm, respectively.

  6. Nuclear cardiology. I - Radionuclide angiographic assessment of left ventricular contraction: uses, limitations and future directions. II - The role of myocardial perfusion imaging using thallium-201 in diagnosis of coronary heart disease

    International Nuclear Information System (INIS)

    Bodenheimer, M.M.; Banka, V.S.; Helfant, R.H.; Pennsylvania, University, Philadelphia, PA)

    1980-01-01

    The current status of radionuclide angiography is reviewed. First pass and gated equilibrium methods for determining left ventricular contraction are compared. Some clinical applications of radionuclide angiography are then examined, including the detection of discrete versus diffuse asynergy and the assessment of myocardial infarction. The second part of this work reviews the uses and limitations of thallium-201 perfusion imaging in the diagnosis of the acute and chronic manifestations of coronary heart disease. Theoretical and technical considerations of thallium-201 imaging are reviewed along with the clinical implications of the technique

  7. Myocardial viability in cases with persistent perfusion defects on the dipyridamole thallium-201 scintigram. A comparative study with autopsy findings

    International Nuclear Information System (INIS)

    Nakayama, Masafumi; Mashima, Saburo; Ohkawa, Shin-ichiro; Tanno, Munehiko; Yamada, Hideo.

    1996-01-01

    The aim of this study was to assess the incidence of myocardial infarction among persistent perfusion defects in dipyridamole-stress thallium scintigraphy by inspecting autopsied hearts and to evaluate whether the regional thallium activity of a scintigraphic defect can predict the presence of infarction. Autopsied hearts were compared with dipyridamole myocardial scintigrams undertaken during life in 27 patients (mean age 85±8 years). The time interval from stress testing until death was 428±351 days. Regional thallium uptake of delayed perfusion defect was calculated on the short axis images. The grade of regional myocardial fibrosis in autopsy specimens was also quantified to correlate with the corresponding regional thallium uptake. In 6 of 15 (40%) regions with persistent defects on the scintigram, myocardial infarction was not found at autopsy. Regional thallium-201 uptake of delayed defects < 50% diagnosed infarction with a sensitivity of 82% and a specificity of 80%. A linear correlation (r=-0.67) was observed between percent thallium-201 uptake and the degree of myocardial fibrosis. In conclusion, perfusion defects at 4-hour imaging in dipyridamole-stress testing may overestimate the presence of myocardial infarction and regional thallium-201 activity is helpful in distinguishing between defects with and without infarction. (author)

  8. The A.R.L. whole body monitor

    International Nuclear Information System (INIS)

    Kotler, L.H.

    1990-02-01

    This report describes a Whole Body Monitor based on four uncollimated NaI(Tl) detectors in a static geometry in use at the Australian Radiation Laboratory. A detailed discussion is presented on the methodology used to estimate the detector efficiency for any arbitrary source whose shape can be described analytically. This procedure is valid for photon emitters in the range 120 keV to 2.6 MeV. By the use of simple geometric models, this approach is applied to the whole body as well as for certain internal organs. For lower photon energies, a discussion of methods using NaI(Tl) detectors to detect in-vivo sources by analysis of pulse-height spectra, is presented. In addition, the application of the Whole Body Monitor in the study of human calcium metabolism, using the tracer 47 Ca is described. Results of measurments on the natural activity of possible candidates for components of the concrete base of the Whole Body Monitor are presented. 74 refs., 22 tabs., 40 figs

  9. Whole-body monitoring: Goiania case, Brazil

    International Nuclear Information System (INIS)

    Oliveira, C.A.N. de; Lourenco, M.C.; Dantas, B.M.; Lucena, E.A. de; Becker, P.H.B.

    1988-01-01

    Due to the radiological Cs accident in Goiania, Goias in September 1987, it became necessary to evaluate internal contamination levels of: individuals from the general public that for any reason had direct or indirect involvement with the radioactive source (group 1); occupationally involved persons (group 2). For each of these groups, procedures of whole body monitoring were developped. In order to attend group 1 individuals, the IRD/CNEN installed a whole body unit in the INAMPS General Hospital of Goiania in 11.08.87, which was later transferred to 121, 57 street, Central Sector in Goiania in 2.06.88. In this unit 547 people were monitored, 356 from group 1 and 241 from group 2, until 04.13.88. In the IRD whole body counter installation, 194 individuals were counted, 185 from group 2 and 9 from group 1. The frequency of monitoring of each individual was stablished according to the Cs activity present in the body or to the job that will be done. Some body burden activity curves for Cs 137 as a function of the time elapsed from the first measurement, are presented. There people from group 1 were measured in both counters, the IRD and the Goiania ones. The values obtained in both installations are compatible with the body activity X time curve. (author) [pt

  10. Improvement of measuring techniques with whole-body and partial-body counters

    International Nuclear Information System (INIS)

    Anon

    1998-01-01

    Mathematical simulation methods have been applied for optimizing and standardizing the calibration of whole-body and partial-body counters for any nuclide accumulation in the human body. (orig./CB) [de

  11. Value of exercise thallium-201 imaging in patients with diagnostic and nondiagnostic exercise electrocardiograms

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Segal, B.L.

    1981-01-01

    The role of exercise imaging with thallium-201 in the evaluation of patients suspected of having coronary artery disease was studied in 194 patients undergoing diagnostic coronary arteriography. Ninety-eight patients had 70 percent or more narrowing of one or more coronary vessels and 96 patients had either no or insignificant coronary artery disease. One hundren twenty-three of the 194 patients had conclusive treadmill exercise electrocardiograms (either positive or negative), and 71 had inconclusive exercise electrocardiograms. The specificity of exercise imaging (97 percent) was higher than that of exercise electrocardiograms (86 percent, p less than 0.02). The specificity of both tests combined was not significantly different from that of exercise electrocardiograms alone. The sensitivity (79 percent) and specificity (95 percent) of exercise imaging were not significantly different in patients with inconclusive exercise electrocardiograms when compared with those in patients whose exercise electrocardiograms were conclusive. These data indicate that exercise imaging is sensitive and specific in diagnosing coronary artery disease in the presence of diagnostic as well as nondiagnostic exercise electrocardiograms and that propranolol therapy does not affect the results

  12. Sorption technique of separation of thallium-201 from proton-irradiated thallium

    International Nuclear Information System (INIS)

    Deptula, Cz.; Zajtseva, N.G.; Mikolaevskij, S.; Khalkin, V.A.

    1989-01-01

    A sorption technique is developed for radiochemical separation of thallium-201 from proton-irradiated targets of metallic thallium. The technique consists in separation of 201 Pb and 201 Tl in the column with ammonium 12-molybdophosphate fixed in the matrix of porous Teflon (AMP-sorbent). The chemical yield of radiothallium is 98 %, the duration of chemical procedures is 2.5-3 hours. 21 refs.; 1 fig.; 1 tab

  13. Stability of Tl(III) in the context of speciation analysis of thallium in plants.

    Science.gov (United States)

    Sadowska, Monika; Biaduń, Ewa; Krasnodębska-Ostręga, Beata

    2016-02-01

    The paper presents both "good" and "bad" results obtained during speciation analysis of thallium in plant tissues of a hyperaccumulator of this metal. The object was white mustard - Sinapis alba L. In this plant there were found traces of trivalent thallium. The crucial point of this study (especially in the case of so unstable thallium form as Tl(III)) was to prove that the presence of Tl(III) was not caused by the procedure of sample preparation itself, and that the whole analytical method provides reliable results. Choice of the method for conservation of the initial speciation, extraction with the highest efficiency and proving the correctness of the obtained data were the most difficult parts of the presented study. It was found that: both freezing and drying cause significant changes in the speciation of thallium; quantitative analysis could be performed only with fresh tissues of mustard plants; only short-term storage of an extract from fresh plant tissues is possible; the methodology is not the source of thallium (III); only the presence of DTPA can greatly limit the reduction of TI(III) to TI(I) (up to 1-3%); the UV irradiation results in disintegration of TI(III)DTPA in the presence of plant matrix (reduction up to 90%). Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Study and development recuperation of Thallium-203 from bombarded targets of this metal in production of Thallium-201 via addition of Thallium-201 radioisotope as a tracer

    International Nuclear Information System (INIS)

    Shirazi, B.

    2006-01-01

    Thallium-203 is the main material for 201 TlCl 3 radiopharmaceutical. It is very important to recover the remaining enriched Thallium-203 in every stage of the process to be reused in the production loop. In this research, the recuperation of Thallium-203 was studied with Dowex 50 WΧ8 ion exchange resin and Thallium-201 as a tracer. The results based on filling of ( 1 8 X 1.5) cm columns with this resin showed that the best flow rate of eluent is 2 ml/min. Also the most suitable volumes are 200 mL (HNO 3 0.05 M), 400 mL (solution of Thallium-203), 100 mL (H 2 O), 500 mL (Citric acid), 100 mL (H 2 0), 100 mL (EDTA 0.5 M and pH∼12.5). 60 mL (H 2 0), respectively

  15. Radio frequency absorption and penetration depth limits in whole body MR imaging

    International Nuclear Information System (INIS)

    Roschmann, P.

    1986-01-01

    There is a continual debate over the ultimate limits to MR imaging at higher field strengths owing to the problems of increasing radio frequency (RF) power deposition and decreasing depth of B/sub 1/ field penetration in the patient. The authors present experimental results of RF absorption and penetration studies in humans for frequencies (f) of 30 to 220 MHz. Results were mostly derived from RF measurements of the effects of loading different types of head, body, and surface coils during imaging of volunteers and metal phantoms. Imaging at 2 T (85 MHz) does not exhibit significant RF problems; the local SAR amounts to 0.06 W/kg for a π-pulse of 1 msec and a TR of 1 sec. RF measurements of coil loading yield SAR -- f/sup 2.2/. The derived effective penetration depth drops from 17 cm at 85 MHz to 7 cm at 220 MHz. Head imaging appears possible up to 220 MHz (5 T). Body and surface coil imaging is subjected to increasing limitations in size or depth above 100 MHz

  16. Normal results of post-race thallium-201 myocardial perfusion imaging in marathon runners with elevated serum MB creatine kinase levels

    International Nuclear Information System (INIS)

    Siegel, A.J.; Silverman, L.M.; Holman, B.L.

    1985-01-01

    Elevated cardiac enzyme values in asymptomatic marathon runners after competition can arise from skeletal muscle through exertional rhabdomyolysis, silent injury to the myocardium, or a combined tissue source. Peak post-race levels of the MB isoenzyme of creatine kinase are similar to values in patients with acute myocardial infarction. Previously reported normal results of infarct-avid myocardial scintigraphy with technetium 99m pyrophosphate in runners after competition suggest a non-cardiac source but cannot exclude silent injury to the myocardium. Therefore, thallium 201 myocardial perfusion imaging was performed in runners immediately after competition together with determination of sequential cardiac enzyme levels. Among 15 runners tested, the average peak in serum MB creatine kinase 24 hours after the race was 128 IU/liter with a cumulative MB creatine kinase release of 117 IU/liter; these values are comparable to those in patients with acute transmural myocardial infarction. Thallium 201 myocardial scintigraphic results were normal in five runners randomly selected from those who volunteered for determination of sequential blood levels. It is concluded that elevations of serum MB creatine kinase in marathon runners arise from a skeletal muscle source and that thallium 201 myocardial scintigraphy is useful to assess runners for myocardial injury when clinical questions arise

  17. Spectral determination of thallium isotope composition

    International Nuclear Information System (INIS)

    Polyanskij, V.A.; Turkin, Yu.I.; Yakimova, N.M.

    1986-01-01

    The photoelectric non-standard method for determination of the thallium isotope composition is developed. The analysis is carried out by measuring the brightness of the Hfs components in the line Tl Iλ535.04 nm. The relative standard deviation of the results of the isotope analysis of thallium as metal is 0.02 and of thallium salts - 0.02-0.05

  18. Exercise thallium-201 scintigraphy in the diagnosis and prognosis of coronary artery disease

    International Nuclear Information System (INIS)

    Kotler, T.S.; Diamond, G.A.

    1990-01-01

    The objective of this study is to determine the discriminant accuracy of exercise thallium-201 myocardial perfusion scintigraphy for the diagnosis and prognosis of patients with known or suspected coronary artery disease. This is a survey of the National Library of Medicine MEDLINE database. The key medical subject headings used were coronary disease, myocardial infarction, radionuclide imaging, and thallium. A total of 122 retrieved studies were considered relevant and were reviewed in depth. Only studies reporting both the sensitivity and specificity of thallium scintigraphy were analyzed. Discriminant accuracy for diagnosis and prognosis was summarized in terms of pooled sensitivity and specificity. Exercise thallium scintigraphy is useful in the noninvasive diagnosis of coronary artery disease, especially in patients with abnormal resting electrocardiograms, restricted exercise tolerance, and intermediate probability of having disease at the time of testing as well as of defining the prognosis of patients with known or suspected coronary artery disease, especially in those with previous myocardial infarction. Because of various shortcomings in the published record, however, the marginal discriminant accuracy and cost effectiveness of thallium scintigraphy compared with conventional clinical assessment and exercise electrocardiography remain controversial. 193 references

  19. Qualification of viable myocardium in the infarcted area by dual isotope In-111 antimyosin Fab and thallium SPECT imaging

    International Nuclear Information System (INIS)

    Mitani, Isao; Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kouhei; Kumita, Shin-ichirou; Oka, Hisatsugu; Haze, Kazuo; Nonoki, Hiroshi

    1991-01-01

    Dual isotope In-111 antimyosin (AM) Fab and thallium SPECT imaging was performed in 33 patients with acute myocardial infarction. Thirteen patients in whom coronary reperfusion could successfully be achieved at the acute stage had higher AM uptake parameters, including AM SCORE, AM AREA, and SCORE/AREA, and the maximum CPK value than the other 20 patients. Left ventricular ejection fraction had a stronger correlation with AM AREA than with AM SCORE (0.601 vs 0.387). Overlap phenomenon was seen in 18 patients (55%). In 28 patients followed up with coronary arteriography, 10 patients had a ≥75% coronary stenosis in the infarct-related vessel; 5 of these 10 had ischemic events. In 13 patients undergoing subsequent thallium-201 scintigraphy at rest, 6 (46%) were found to have marked reduction of perfusion defect (the improved group). Regarding thallium-201 DEFECT SCORE early after the onset of myocardial infarction, there was no significant difference between the aforementioned improved group (15±5) and the non-improved group (17±7). However, In-111 AM uptake in the infarct area was smaller in the improved group than the non-improved group, which means that the infarcted area did not become necrotic early after the onset of myocardial infarction. This may have been responsible for the improvement of perfusion defect in cases of myocardial infarction. (N.K.)

  20. Whole body MRI in the diagnosis of chronic recurrent multifocal osteomyelitis.

    LENUS (Irish Health Repository)

    Kennedy, M T

    2012-06-01

    Chronic recurrent multifocal osteomyelitis (CRMO) is a diagnosis of exclusion primarily in children and adolescents. As part of the essential criteria for the diagnosis of CRMO, multifocal lesions must be identified. We present the case of an 11-year-old boy with CRMO, whose diagnosis was facilitated by the use of whole body magnetic resonance imaging (WBMR), but not isotope bone scanning.

  1. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  2. Thallium-201 scintigraphy of the heart in patients prior to aortocoronary bypass

    International Nuclear Information System (INIS)

    Nestaval, A.; Malek, I.; Jirickova, E.; Peregrin, J.; Kidery, J.; Oppelt, A.

    1986-01-01

    Scintigraphic examinations of the heart muscle were made using thallium-201 in 16 male patients with symptomatic ischemic heart disease, who were indicated for an aortocoronary bypass. The radionuclide was administered during exercise and the scintigrams were taken after 20 minutes and after 4 hours following administration. The images of the heart processed by computer were correlated with coronarographic findings. All 16 patients had stenoses of 1 to 3 coronary arteries. In 12 patients defects were found on the thallium scan in all areas corresponding to the coronarography, in the remaining four patients the defect was only on one of the affected branches of the coronary arteries. There were no false positive finding. The results suggest very satisfactory sensitivity of thallium scintigraphy in patients with severe coronary atherosclerosis. (author)

  3. ECAT III: A new PET system for heart and whole body dynamic imaging

    International Nuclear Information System (INIS)

    Hoffman, E.J.; Phelps, M.E.; Huang, S.C.; Collard, P.E.; Bidaut, L.M.; Schwab, R.L.; Schwaiger, M.; Schelbert, H.R.

    1985-01-01

    A new whole body PET system has been developed and is being evaluated. The ECAT III consists of 1 to 4 rings of 512-5.6 x 29 x 30 mm BGO detectors per 100 cm diameter ring. The system has a unique data collection scheme in which all events are buffered in a 512 by 32 data matrix. The 512 dimension corresponds to detector number and the 32 dimension corresponds to 8 nsec time bins. A dedicated microprocessor searches the array (1) to determine which detectors had events simultaneously +- 8 nsec to establish coincidences, (2) to determine accidentals by determining the probability of off-time events, which can be determined with a statistical accuracy improvement of a factor of 10 by using a larger ''software'' time window, and (3) to determine and distinguish between adjacent detector crosstalk and random triple events. System can process 500 K coincident events/sec/per image plane. Data are collected in list mode and scan parameter information, such as time, wobble position and occurrence of gating signals are inserted in data. Wobble position is divided in 1000 parts per rotation, minimizing positioning error in binning events, timing information allows retrospective choice of time frame for dynamic studies and cardiac gate data allows retrospective choice of framing. ECAT III has an image resolution of 4.5 mm when system is wobbled and 7.2 mm when system is stationary. Loss of efficiency due to nearest neighbor cross talk is 8 to 12%. Axial resolution is selectable with remotely driven side shielding, and interchangeable interplane sept allow different configurations to accomodate a variety of imaging conditions

  4. Quantitative image reconstruction for total-body PET imaging using the 2-meter long EXPLORER scanner

    Science.gov (United States)

    Zhang, Xuezhu; Zhou, Jian; Cherry, Simon R.; Badawi, Ramsey D.; Qi, Jinyi

    2017-03-01

    The EXPLORER project aims to build a 2 meter long total-body PET scanner, which will provide extremely high sensitivity for imaging the entire human body. It will possess a range of capabilities currently unavailable to state-of-the-art clinical PET scanners with a limited axial field-of-view. The huge number of lines-of-response (LORs) of the EXPLORER poses a challenge to the data handling and image reconstruction. The objective of this study is to develop a quantitative image reconstruction method for the EXPLORER and compare its performance with current whole-body scanners. Fully 3D image reconstruction was performed using time-of-flight list-mode data with parallel computation. To recover the resolution loss caused by the parallax error between crystal pairs at a large axial ring difference or transaxial radial offset, we applied an image domain resolution model estimated from point source data. To evaluate the image quality, we conducted computer simulations using the SimSET Monte-Carlo toolkit and XCAT 2.0 anthropomorphic phantom to mimic a 20 min whole-body PET scan with an injection of 25 MBq 18F-FDG. We compare the performance of the EXPLORER with a current clinical scanner that has an axial FOV of 22 cm. The comparison results demonstrated superior image quality from the EXPLORER with a 6.9-fold reduction in noise standard deviation comparing with multi-bed imaging using the clinical scanner.

  5. Targeted microbubbles for imaging tumor angiogenesis: assessment of whole-body biodistribution with dynamic micro-PET in mice

    DEFF Research Database (Denmark)

    Willmann, Jürgen K; Cheng, Zhen; Davis, Corrine

    2008-01-01

    To evaluate in vivo whole-body biodistribution of microbubbles (MBs) targeted to tumor angiogenesis-related vascular endothelial growth factor (VEGF) receptor 2 (VEGFR2) by using dynamic micro-positron emission tomography (PET) in living mice.......To evaluate in vivo whole-body biodistribution of microbubbles (MBs) targeted to tumor angiogenesis-related vascular endothelial growth factor (VEGF) receptor 2 (VEGFR2) by using dynamic micro-positron emission tomography (PET) in living mice....

  6. Dipyridamole-thallium scanning in patients undergoing vascular surgery. Optimizing preoperative evaluation of cardiac risk

    International Nuclear Information System (INIS)

    Eagle, K.A.; Singer, D.E.; Brewster, D.C.; Darling, R.C.; Mulley, A.G.; Boucher, C.A.

    1987-01-01

    Dipyridamole-thallium imaging has been suggested as a method of preoperatively assessing cardiac risk in patients undergoing major surgery. To define more clearly its proper role in preoperative assessment, we prospectively evaluated 111 patients undergoing vascular surgery. In the first set of 61 patients, our data confirmed the value of preoperative dipyridamole-thallium scanning in identifying the patients who suffered postoperative ischemic events. Events occurred in eight of 18 patients with reversible defects on preoperative imaging, compared with no events in 43 patients with no thallium redistribution (confidence interval for the risk difference: 0.624, 0.256). The results also suggested that clinical factors might allow identification of a low-risk subset of patients. To test the hypothesis that patients with no evidence of congestive heart failure, angina, prior myocardial infarction, or diabetes do not require further preoperative testing, we evaluated an additional 50 patients having vascular procedures. None of the 23 without the clinical markers had untoward outcomes, while ten of 27 patients with one or more of these clinical markers suffered postoperative ischemic events (confidence interval for the risk difference: 0.592, 0.148). In the clinical high-risk subset, further risk stratification is achieved with dipyridamole-thallium scanning

  7. IRIS Toxicological Review of Thallium and Compounds (External Review Draft)

    Science.gov (United States)

    Thallium compounds are used in the semiconductor industry, the manufacture of optic lenses and low-melting glass, low-temperature thermometers, alloys, electronic devices, mercury lamps, fireworks, and imitation germs, and clinically as an imaging agent in the diagnosis of certai...

  8. Whole-body magnetic resonance angiography with blood-pool agents

    International Nuclear Information System (INIS)

    Kramer, H.; Morana, G.

    2007-01-01

    Although often asymptomatic, peripheral arterial disease (PAD) is associated with significant morbidity in a large proportion of patients. Atherosclerosis is the underlying pathology in many instances, involving the whole arterial tree. Whole-body magnetic resonance angiography (MRA) permits rapid, non-invasive and accurate evaluation of the entire vascular system and can be used for both diagnostic purposes and monitoring of vascular involvement in diseases such as diabetes, Marfan's syndrome and Takayasu arteritis. MRA has been used successfully in the identification of high-grade stenosis in PAD, abnormalities of the ileocaval veins and carotid plaque imaging. Carotid disease is significantly correlated with severe coronary artery disease and renal artery atherosclerosis. Symptomatic lesions in one vascular bed are often related to additional asymptomatic atherosclerotic lesions in other vascular regions. MRA may be advantageous over computed tomographic angiography because it can be performed with contrast media virtually devoid of serious toxicity and without utilization of ionizing radiation. Display of the entire arterial vasculature can be achieved in < 90 s, with excellent sensitivity and specificity. Recent technological advances, such as parallel imaging and the implementation of dedicated matrix coils, have further increased image quality, and in combination with the blood-pool contrast agents, such as gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany), extended imaging time, higher spatial resolution and larger anatomical coverage can be achieved. (orig.)

  9. Whole-body magnetic resonance angiography with blood-pool agents

    Energy Technology Data Exchange (ETDEWEB)

    Kramer, H. [Inst. for Clinical Radiology, Univ. Hospital Munich, Munich (Germany); Morana, G. [Radiological Dept., Hospital Ca' Foncello, Treviso (Italy)

    2007-03-15

    Although often asymptomatic, peripheral arterial disease (PAD) is associated with significant morbidity in a large proportion of patients. Atherosclerosis is the underlying pathology in many instances, involving the whole arterial tree. Whole-body magnetic resonance angiography (MRA) permits rapid, non-invasive and accurate evaluation of the entire vascular system and can be used for both diagnostic purposes and monitoring of vascular involvement in diseases such as diabetes, Marfan's syndrome and Takayasu arteritis. MRA has been used successfully in the identification of high-grade stenosis in PAD, abnormalities of the ileocaval veins and carotid plaque imaging. Carotid disease is significantly correlated with severe coronary artery disease and renal artery atherosclerosis. Symptomatic lesions in one vascular bed are often related to additional asymptomatic atherosclerotic lesions in other vascular regions. MRA may be advantageous over computed tomographic angiography because it can be performed with contrast media virtually devoid of serious toxicity and without utilization of ionizing radiation. Display of the entire arterial vasculature can be achieved in < 90 s, with excellent sensitivity and specificity. Recent technological advances, such as parallel imaging and the implementation of dedicated matrix coils, have further increased image quality, and in combination with the blood-pool contrast agents, such as gadofosveset trisodium (Vasovist, Bayer Schering Pharma AG, Berlin, Germany), extended imaging time, higher spatial resolution and larger anatomical coverage can be achieved. (orig.)

  10. Massive mercury target for thallium isotope production on the beam of high energy protons

    International Nuclear Information System (INIS)

    Novgorodov, A.F.; Kolachkovski, A.; Nguen Kong Chang.

    1980-01-01

    The yields of thallium radioisotopes in a massive mercury target irradiated with 660 MeV protons have been determined. The constancy of isotopic composition of radiothallium along the whole length (40 cm) of the target has been found. The yields of 200 Tl, 201 Tl and 202 Tl amount to 22.9+-2.8; 3.42+-0.45 and 0.459+-0.61 mCu/mkA h, respectively. It has been shown that the extraction of radioisotopes of thallium and some other elements from large amounts of mercury as well as their subsequent concentration may be carried out fully and relatavely fast when using dilute solutions of acetic acid

  11. Whole body plastination, intra-organ heterogeneity, and tissue based diagnosis – a survey

    Directory of Open Access Journals (Sweden)

    Gunther von Hagens

    2018-04-01

    Full Text Available  Background: The corpse is the final structural relict of life. Its detailed analysis, the autopsy formed the basis and contributed significantly to our understanding of location, function and interaction of organs in man. Today, autopsies are performed rarely. They have been replaced by radiological in vivo visualization techniques and the analysis of organ excisions and biopsies. Which attributes do whole body preservations possess in this context? Techniques of Whole Body Analysis: In vivo imaging transfers the appearance of body organs and cellular structures in virtual images. The patient’s exposure to X-rays, fundamental particles (electrons, positrons, etc., strong magnetic fields (nuclear resonance, or ultra sounds release the corresponding signals. The obtained images are interpreted in search for local abnormalities such as cancer, acute and chronic infections, inborn errors, hypertrophy or atrophy. Autopsies require the removal and visual inspection of organs shortly after the victim’s death. In addition, tissue probes of suspicious lesions are fixed and microscopically analyzed. The search for gene or protein abnormalities are added dependent upon the clinical history and gross findings. The whole body plastination is performed in separated steps which include fixation, anatomical dissection, forced polymer impregnation, positioning and curing. Organs and other tissue structures can be taken out of the body and separately demonstrated, or aligned and fixed within the body. Additional tissue examinations are possible at this stage, which is followed by hardening and fixation of the still flexible body. Fixation is done with heat, light or gas.   Results and Interpretation: Tissue conservation is a prerequisite to analyze and investigate in diagnosis and forecast of disease occurrence and behaviour. In history, autopsies have opened the door to localize the position and to understand the functions of organs. Today, they have been

  12. Using a whole-body 31P birdcage transmit coil and 16-element receive array for human cardiac metabolic imaging at 7T.

    Directory of Open Access Journals (Sweden)

    Ladislav Valkovič

    Full Text Available Cardiac phosphorus magnetic resonance spectroscopy (31P-MRS provides unique insight into the mechanisms of heart failure. Yet, clinical applications have been hindered by the restricted sensitivity of the surface radiofrequency-coils normally used. These permit the analysis of spectra only from the interventricular septum, or large volumes of myocardium, which may not be meaningful in focal disease. Löring et al. recently presented a prototype whole-body (52 cm diameter transmit/receive birdcage coil for 31P at 7T. We now present a new, easily-removable, whole-body 31P transmit radiofrequency-coil built into a patient-bed extension combined with a 16-element receive array for cardiac 31P-MRS.A fully-removable (55 cm diameter birdcage transmit coil was combined with a 16-element receive array on a Magnetom 7T scanner (Siemens, Germany. Electro-magnetic field simulations and phantom tests of the setup were performed. In vivo maps of B1+, metabolite signals, and saturation-band efficiency were acquired across the torsos of eight volunteers.The combined (volume-transmit, local receive array setup increased signal-to-noise ratio 2.6-fold 10 cm below the array (depth of the interventricular septum compared to using the birdcage coil in transceiver mode. The simulated coefficient of variation for B1+ of the whole-body coil across the heart was 46.7% (surface coil 129.0%; and the in vivo measured value was 38.4%. Metabolite images of 2,3-diphosphoglycerate clearly resolved the ventricular blood pools, and muscle tissue was visible in phosphocreatine (PCr maps. Amplitude-modulated saturation bands achieved 71±4% suppression of phosphocreatine PCr in chest-wall muscles. Subjects reported they were comfortable.This easy-to-assemble, volume-transmit, local receive array coil combination significantly improves the homogeneity and field-of-view for metabolic imaging of the human heart at 7T.

  13. Segmentation and visual analysis of whole-body mouse skeleton microSPECT.

    Directory of Open Access Journals (Sweden)

    Artem Khmelinskii

    Full Text Available Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality, postural and positioning variability. The goal of this study was to provide a method to align and compare side-by-side multiple whole-body skeleton SPECT datasets in a common reference, thus eliminating acquisition variability that exists between the subjects in cross-sectional and multi-modal studies. Six whole-body SPECT/CT datasets of BALB/c mice injected with bone targeting tracers (99mTc-methylene diphosphonate ((99mTc-MDP and (99mTc-hydroxymethane diphosphonate ((99mTc-HDP were used to evaluate the proposed method. An articulated version of the MOBY whole-body mouse atlas was used as a common reference. Its individual bones were registered one-by-one to the skeleton extracted from the acquired SPECT data following an anatomical hierarchical tree. Sequential registration was used while constraining the local degrees of freedom (DoFs of each bone in accordance to the type of joint and its range of motion. The Articulated Planar Reformation (APR algorithm was applied to the segmented data for side-by-side change visualization and comparison of data. To quantitatively evaluate the proposed algorithm, bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances between each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance decreased from 11.5±12.1 to 2.6±2.1 voxels. The proposed approach yielded satisfactory segmentation results with minimal user intervention. It proved to be robust for "incomplete" data (large chunks of skeleton missing and for an intuitive exploration and comparison of multi-modal SPECT

  14. Applying preoperative dipyridamole thallium-201 scintigraphy for preventing cardiac mortality and complications for patients with secondary hyperparathyroidism undergoing parathyroidectomy

    Directory of Open Access Journals (Sweden)

    Shih-min Yin

    2018-05-01

    Full Text Available Summary: Background: To evaluate the value of preoperative dipyridamole thallium-201 scintigraphy for reducing cardiovascular complication in secondary hyperparathyroidism (SHPTH patients. Methods: Thallium scintigraphy was arranged for all dialysis patients who underwent parathyroidectomy from Jan 2011 to July 2015. Management of defects on thallium scintigraphy included cardiac catheterization and ultrasonography. Analysis includes 30-day mortality, morbidity and the predicting factors for thallium scintigraphy defect. Results: Of 249 patients with SHPTH, 19 (7.6% had defects on thallium scintigraphy, 15 (88% of whom had coronary artery disease on angiography. History of acute coronary syndrome (ACS, p < 0.001, diabetes mellitus (DM, p = 0.03, male sex (p = 0.03, and higher body mass index (BMI, p = 0.001 were significant predictors of positive thallium scintigraphy results. History of ACS was the most significant predictor after adjustment in the multivariate logistic analysis (odds ratio, 22.56; 95% confidence interval, 7.02–72.53. All the patients survived the 30-day postoperative period, with minimal cardiovascular morbidity. Conclusion: Preoperative dipyridamole thallium-201 scintigraphy is useful for SHPTH patients to minimized surgical mortality and morbidity. Keywords: Secondary hyperparathyroidism, Dialysis, Coronary artery disease (CAD, Dipyridamole thallium-201 scintigraphy

  15. Isolation of radioactive thallium from lead targets

    International Nuclear Information System (INIS)

    Kozlova, M.D.; Sevast'yanova, A.S.; Malinin, A.B.; Kurenkov, N.V.

    1989-01-01

    Two methods of thallium-201 preperation from Pb-targets irradiated with protons: precipitation-extraction (1) and extraction (2) - are developed. When the target irraiated is extracted during the time necessary for bismuth-201 transformation into lead-201, lead macroquantity containing lead-201 was separated from undesirable thallium radionuclides, which are formed in direct nuclear reactions. The lead fraction was extracted to accumulate thallium-201, and it was separated from lead mocroquantity. The target was dissolved in the nitric acid. The 1st method differs from the 2nd one by the fact that before thallium-201 extraction, lead was precipitaed by the nitric acid. The 1st method permits to separate thallium-201 with chemical yield not less than 90 %, the 2nd one - ≥95 %. 2 refs

  16. Evaluation of diagnostic performance of whole-body simultaneous PET/MRI in pediatric lymphoma

    International Nuclear Information System (INIS)

    Ponisio, Maria Rosana; Laforest, Richard; Khanna, Geetika; McConathy, Jonathan

    2016-01-01

    Whole-body 18 F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is the standard of care for lymphoma. Simultaneous PET/MRI (magnetic resonance imaging) is a promising new modality that combines the metabolic information of PET with superior soft-tissue resolution and functional imaging capabilities of MRI while decreasing radiation dose. There is limited information on the clinical performance of PET/MRI in the pediatric setting. This study evaluated the feasibility, dosimetry, and qualitative and quantitative diagnostic performance of simultaneous whole-body FDG-PET/MRI in children with lymphoma compared to PET/CT. Children with lymphoma undergoing standard of care FDG-PET/CT were prospectively recruited for PET/MRI performed immediately after the PET/CT. Images were evaluated for quality, lesion detection and anatomical localization of FDG uptake. Maximum and mean standardized uptake values (SUV max/mean ) of normal organs and SUV max of the most FDG-avid lesions were measured for PET/MRI and PET/CT. Estimation of radiation exposure was calculated using specific age-related factors. Nine PET/MRI scans were performed in eight patients (mean age: 15.3 years). The mean time interval between PET/CT and PET/MRI was 51 ± 10 min. Both the PET/CT and PET/MRI exams had good image quality and alignment with complete (9/9) concordance in response assessment. The SUVs from PET/MRI and PET/CT were highly correlated for normal organs (SUV mean r 2 : 0.88, P<0.0001) and very highly for FDG-avid lesions (SUV max r 2 : 0.94, P=0.0002). PET/MRI demonstrated an average percent radiation exposure reduction of 39% ± 13% compared with PET/CT. Simultaneous whole-body PET/MRI is clinically feasible in pediatric lymphoma. PET/MRI performance is comparable to PET/CT for lesion detection and SUV measurements. Replacement of PET/CT with PET/MRI can significantly decrease radiation dose from diagnostic imaging in children. (orig.)

  17. A comparative study of 18F-fluorodeoxyglucose positron emission tomography/computed tomography and 99mTc-MDP whole-body bone scanning for imaging osteolytic bone metastases

    International Nuclear Information System (INIS)

    Zhang, Lin; Chen, Lihua; Xie, Qiao; Zhang, Yongke; Cheng, Lin; Li, Haitao; Wang, Jian

    2015-01-01

    The objective of this study was to evaluate the feasibility and diagnostic value of 18 F-fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG PET/CT) and 99m Tc-methylenediphosphonate (MDP) whole-body bone scanning (BS) for the detection of osteolytic bone metastases. Thirty-four patients with pathologically confirmed malignancies and suspected osteolytic bone metastases underwent 18 F-FDG PET/CT and 99m Tc-MDP whole-body BS within 30 days. The sensitivity, specificity, and accuracy with respect to the diagnosis of osteolytic bone metastases and bone lesions were compared between the two imaging methods. The sensitivity, specificity, and accuracy of 18 F-FDG PET/CT for the diagnosis of osteolytic bone metastases were 94.3% (95% confidence interval [CI], 91.6–96.2%), 83.3% (95% CI, 43.6–96.9%), and 94.2% (95% CI, 91.5–96.1%), respectively. It was found that 99m Tc-MDP whole-body BS could discriminate between patients with 50.2% (95% CI, 45.4–55.1%) sensitivity, 50.0% (95% CI, 18.8–81.2%) specificity, and 50.2% (95% CI, 45.5–55.1%) accuracy. 18 F-FDG PET/CT achieved higher sensitivity, specificity, and accuracy in detecting osteolytic bone metastases than 99mTc-MDP whole-body BS (p<0.001). F-FDG PET/CT has a higher diagnostic value than 99m Tc-MDP whole-body BS in the detection of osteolytic bone metastases, especially in the vertebra

  18. Thallium in mineral resources extracted in Poland

    Directory of Open Access Journals (Sweden)

    Bojakowska I.

    2013-04-01

    Full Text Available Thallium concentrations in primary mineral commodities extracted in Poland and processed in high temperatures were determined by ICP-MS method. Samples of hard and brown coal, copper-silver and zinclead ores, argillaceous and calcareous rocks of different genesis and age were analyzed. The highest thallium concentrations occur in the zinc-lead ores, the average content being of 52.1 mg/kg. The copper ores contain in average 1.4 mg/kg of thallium. Hard coals from the Upper Silesian Coal Basin display higher thallium content than those exploited in the Lublin Coal Basin. Brown coals from Turow deposit distinguish by much higher values, 0.7 mg/kg Tl, than those from huge Bełchatów and smaller Konin-Turek region deposits. Average thallium concentrations in clays used for ceramic materials are lower than 1 mg/kg, except of Mio-Pliocene Slowiany deposit. The average content of thallium in the studied limestone and dolomite raw materials for cement, lime, and metallurgical flux, and refractories is very low in comparison to the average amounts in the world carbonate rocks.

  19. The ORNL whole body counter

    International Nuclear Information System (INIS)

    1988-01-01

    This report is a non-technical document intended to provide an individual about to undergo a whole-body radiation count with a general understanding of the counting procedure and with the results obtained. 9 figs

  20. Interpolation method by whole body computed tomography, Artronix 1120

    International Nuclear Information System (INIS)

    Fujii, Kyoichi; Koga, Issei; Tokunaga, Mitsuo

    1981-01-01

    Reconstruction of the whole body CT images by interpolation method was investigated by rapid scanning. Artronix 1120 with fixed collimator was used to obtain the CT images every 5 mm. X-ray source was circully movable to obtain perpendicular beam to the detector. A length of 150 mm was scanned in about 15 min., with the slice width of 5 mm. The images were reproduced every 7.5 mm, which was able to reduce every 1.5 mm when necessary. Out of 420 inspection in the chest, abdomen, and pelvis, 5 representative cases for which this method was valuable were described. The cases were fibrous histiocytoma of upper mediastinum, left adrenal adenoma, left ureter fibroma, recurrence of colon cancer in the pelvis, and abscess around the rectum. This method improved the image quality of lesions in the vicinity of the ureters, main artery, and rectum. The time required and exposure dose were reduced to 50% by this method. (Nakanishi, T.)

  1. Measurement of Organ Uptake by Whole-Body Counting

    International Nuclear Information System (INIS)

    Dudley, R.A.

    1970-01-01

    This paper reviews methods for the measurement of radioactivity in body organs based on whole-body radioactivity measurements. Such measurements can of course only be used to measure radioactivity in a body organ when the radioactivity is exclusively localized in the organ or when the ratio of radioactivity in the organ to that in the whole body is known from other sources of information. They find particular applications, however, when the organ is so widely dispersed throughout the body that more localized measurement is impossible. Examples of situations in which whole-body radioactivity measurements have been used in this way are cited. The more important techniques used for such measurements are described and their respective advantages and disadvantages indicated. The importance of uniformity of counting efficiency with position of source throughout the body is stressed. Simple systems incorporating sodium iodide crystal scintillation detectors are shown to combine satisfactory sensitivity and uniformity of efficiency for clinical measurements of radioactivity in body organs and have the additional advantage that they can be readily adapted for profile scanning. Systems incorporating plastic or liquid scintillation detectors are less convenient in this respect. (author)

  2. Measurement of caesium-137 in the human body using a whole body counter

    Science.gov (United States)

    Elessawi, Elkhadra Abdulmula

    Gamma radiation in the environment is mainly due to naturally occurring radionuclides. However, there is also a contribution from anthropogenic radionuclides such as 137Cs which originate from nuclear fission processes. Since 1986, the accident at the Chernobyl power plant has been a significant source of artificial environmental radioactivity. In order to assess the radiological impact of these radionuclides, it is necessary to measure their activities in samples drawn from the environment and in plants and animals including human populations. The whole body counter (WBC) at the University Hospital of Wales in Cardiff makes in vivo measurements of gamma emitting radionuclides using a scanning ring of six large-volume thallium-doped sodium iodide (Nal(Tl)) scintillation detectors. In this work the WBC was upgraded by the addition of two high purity germanium (HPGe) detectors. The performance and suitability of the detection systems were evaluated by comparing the detection limits for Cs. Sensitivities were measured using sources of known activity in a water filled anthropomorphic phantom and theoretical minimum detectable count-rates were estimated from phantom background pulse height spectra. The theoretical minimum detectable activity was about 24 Bq for the combination of six Nal(Tl) detectors whereas for the individual HPGe detectors it was 64 Bq and 65 Bq, despite the much improved energy resolution Activities of 137Cs in the human body between 1993 and 2007 were estimated from the background Nal(Tl) spectra of 813 patients and compared with recent measurements in 14 volunteers. The body burden of Cs in Cardiff patients increased from an average of about 60 Bq in the early and mid 1990s to a maximum of about 100 Bq in 2000. By 2007 it had decreased to about 40 Bq. This latter value was similar to that of Cardiff residents at the time of the Chernobyl accident and to that of the volunteers measured in 2007 (51 Bq). However, it was less than the mean activity of

  3. Whole-body CT for lymphoma staging: Feasibility of halving radiation dose and risk by iterative image reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, M., E-mail: mathias.meyer@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Klein, S.A., E-mail: stefan.klein@umm.de [Department of Hematology and Oncology, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Brix, G., E-mail: gbrix@bfs.de [Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Ingolstädter Landstraße 1, D-85764 Neuherberg (Germany); Fink, C., E-mail: Christian.Fink@medma.uni-heidelberg.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Pilz, L., E-mail: lothar.pilz@medma.uni-heidelberg.de [Department of Biostatistics, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Jafarov, H., E-mail: Hashim.Jafarov@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Hofmann, W.K., E-mail: w.k.hofmann@umm.de [Department of Hematology and Oncology, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Schoenberg, S.O., E-mail: Stefan.Schoenberg@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Medical Faculty Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); and others

    2014-02-15

    Objectives: Patients with lymphoma are at higher-risk of secondary malignancies mainly due to effects of cancer therapy as well as frequent radiological surveillance. We thus aimed to investigate the objective and subjective image quality as well as radiation exposure and risk of full-dose standard (FDS), full-dose iterative (FDI), and half-dose iterative (HDI) image reconstruction in patients with lymphoma. Material and methods: In 100 lymphoma patients, contrast-enhanced whole-body staging was performed on a dual-source CT. To acquire full-dose and half-dose CT data simultaneously, the total current-time product was equally distributed on both tubes operating at 120 kV. HDI reconstructions were calculated by using only data from one tube. Quantitative image quality was assessed by measuring image noise in different tissues of the neck, thorax, and abdomen. Overall diagnostic image quality was assessed using a 5-point Likert scale. Radiation doses and risks were estimated for a male and female reference person. Results: For all anatomical regions apart from the lungs image noise was significantly lower and the overall subjective image quality significantly better when using FDI and HDI instead of FDS reconstruction (p < 0.05). For the half-dose protocol, the risk to develop a radiation-induced cancer was estimated to be less than 0.11/0.19% for an adult male/female. Conclusions: Image quality of FDI and more importantly of HDI is superior to FDS reconstruction, thus enabling to halve radiation dose and risk to lymphoma patients.

  4. Thallium-201 myocardial perfusion imaging during adenosine-induced coronary vasodilation in patients with ischemic heart disease

    International Nuclear Information System (INIS)

    Takeishi, Yasuchika; Chiba, Junya; Abe, Shinya

    1992-01-01

    Thallium-201 ( 201 Tl) myocardial perfusion imaging during adenosine infusion was performed in consecutive 55 patients with suspected coronary artery disease. Adenosine was infused intravenously at a rate of 0.14 mg/kg/min for 6 minutes and a dose of 111 MBq of 201 Tl was administered in a separate vein at the end of third minutes of infusion. Myocardial SPECT imaging was begun 5 minutes and 3 hours after the end of adenosine infusion. For evaluating the presence of perfusion defects, 2 short axis images at the basal and spical levels and a vertical long axis image at the mid left ventricle were used. The regions with decreased 201 Tl uptake were assessed semi-quantitatively. Adenosine infusion caused a slight reduction in systolic blood pressure and an increase in heart rate. The rate pressure products increased slightly (9314±2377 vs. 10360±2148, p 201 Tl myocardial imaging during adenosine infusion was considered to be safe and useful for evaluating the patients with ischemic heart disease. (author)

  5. Magnetic Resonance Imaging in the measurement of whole body muscle mass: A comparison of interval gap methods

    International Nuclear Information System (INIS)

    Hellmanns, K.; McBean, K.; Thoirs, K.

    2015-01-01

    Purpose: Magnetic Resonance Imaging (MRI) is commonly used in body composition research to measure whole body skeletal muscle mass (SM). MRI calculation methods of SM can vary by analysing the images at different slice intervals (or interval gaps) along the length of the body. This study compared SM measurements made from MRI images of apparently healthy individuals using different interval gap methods to determine the error associated with each technique. It was anticipated that the results would inform researchers of optimum interval gap measurements to detect a predetermined minimum change in SM. Methods: A method comparison study was used to compare eight interval gap methods (interval gaps of 40, 50, 60, 70, 80, 100, 120 and 140 mm) against a reference 10 mm interval gap method for measuring SM from twenty MRI image sets acquired from apparently healthy participants. Pearson product-moment correlation analysis was used to determine the association between methods. Total error was calculated as the sum of the bias (systematic error) and the random error (limits of agreement) of the mean differences. Percentage error was used to demonstrate proportional error. Results: Pearson product-moment correlation analysis between the reference method and all interval gap methods demonstrated strong and significant associations (r > 0.99, p < 0.0001). The 40 mm interval gap method was comparable with the 10 mm interval reference method and had a low error (total error 0.95 kg, −3.4%). Analysis methods using wider interval gap techniques demonstrated larger errors than reported for dual-energy x-ray absorptiometry (DXA), a technique which is more available, less expensive, and less time consuming than MRI analysis of SM. Conclusions: Researchers using MRI to measure SM can be confident in using a 40 mm interval gap technique when analysing the images to detect minimum changes less than 1 kg. The use of wider intervals will introduce error that is no better

  6. Intercalibration of CDTN and IRD whole body counters

    International Nuclear Information System (INIS)

    Dantas, B.M.; Dantas, A.L.A.; Alonso, T.C.

    2008-01-01

    Full text: Intercalibration exercises are designed to harmonize analytical techniques and ensure reliability of measurement results performed in a laboratory network. Such strategy helps to improve laboratory performance among participants in future intercomparison exercises, when it is verified the metrological capacity, by determining accuracy, precision and reproducibility of data produced by each laboratory. In Brazil, there are currently four in vivo monitoring systems, located in IRD, in Rio de Janeiro, CDTN, in Belo Horizonte, IPEN, in Sao Paulo and CNAAA, in Angra dos Reis. Such systems, generically referred as whole body counters, aim to detect and quantify radionuclides in organs and tissues for radiological protection purposes and to provide useful information for studies on biokinetic behavior of radionuclides in humans and animals. The objective of this work is to establish a methodology to be applied for intercalibration of whole body counters. The IRD whole body counter is installed in a 15 cm steel shielded room where two NaI(Tl) and four HPGe detectors are calibrated for the determination of radionuclides in the energy range from 10 to 3000 keV. The CDTN whole body counter has one NaI detector set up in a shadow shield configuration, and is able to determine radionuclides emitting photons from 100 to 2000 keV. The intercalibration exercise described in this work was planed for whole body geometry using the scintillation detectors available in both laboratories. It was used a thin glass vial containing 2,6615 g of a solution of four gamma emitters ( 57 Co, 137 Cs, 54 Mn, 65 Zn), supplied by the National Laboratory for Metrology of Ionizing Radiation (LNMRI-IRD). The glass vial was measured in the same geometry in both IRD and CDTN whole body counters, being positioned at 31,5 cm distance from the NaI(Tl) detector of each laboratory. The calibration curves (photo peak channel and Efficiency vs Energy) of each detection system were compared. The

  7. Evaluation of dual-source parallel RF excitation for diffusion-weighted whole-body MR imaging with background body signal suppression at 3.0 T.

    Science.gov (United States)

    Mürtz, Petra; Kaschner, Marius; Träber, Frank; Kukuk, Guido M; Büdenbender, Sarah M; Skowasch, Dirk; Gieseke, Jürgen; Schild, Hans H; Willinek, Winfried A

    2012-11-01

    To evaluate the use of dual-source parallel RF excitation (TX) for diffusion-weighted whole-body MRI with background body signal suppression (DWIBS) at 3.0 T. Forty consecutive patients were examined on a clinical 3.0-T MRI system using a diffusion-weighted (DW) spin-echo echo-planar imaging sequence with a combination of short TI inversion recovery and slice-selective gradient reversal fat suppression. DWIBS of the neck (n=5), thorax (n=8), abdomen (n=6) and pelvis (n=21) was performed both with TX (2:56 min) and with standard single-source RF excitation (4:37 min). The quality of DW images and reconstructed inverted maximum intensity projections was visually judged by two readers (blinded to acquisition technique). Signal homogeneity and fat suppression were scored as "improved", "equal", "worse" or "ambiguous". Moreover, the apparent diffusion coefficient (ADC) values were measured in muscles, urinary bladder, lymph nodes and lesions. By the use of TX, signal homogeneity was "improved" in 25/40 and "equal" in 15/40 cases. Fat suppression was "improved" in 17/40 and "equal" in 23/40 cases. These improvements were statistically significant (p3.0 T with respect to signal homogeneity and fat suppression, reduced scan time by approximately one-third, and did not influence the measured ADC values. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Internal dosimetry by whole body counting techniques

    International Nuclear Information System (INIS)

    Sharma, R.C.

    1995-01-01

    Over decades, whole body counting and bioassay - the two principal methods of internal dosimetry have been most widely used to assess, limit and control the intakes of radioactive materials and the consequent internal doses by the workers in nuclear industry. This paper deals with the whole body counting techniques. The problems inherent in the interpretation of monitoring data and likely future directions of development in the assessments of internal doses by direct methods are outlined. (author). 14 refs., 9 figs., 1 tab

  9. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

    Science.gov (United States)

    Okudan, Berna; Smitherman, Thomas C

    2004-06-01

    Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2-day rest/stress Tc-99m sestamibi protocols are time-consuming. Hence, the dual isotope rest thallium-201/stress technetium-99m sestamibi gated single-photon emission tomography protocol has gained increasing popularity for these applications. Combining the use of thallium-201 with technetium-99m agents permits optimal image resolution and simultaneous assessment of viability. Dual-isotope imaging may be separate or simultaneous acquisition set-up. The more rapid completion of these studies is appreciated as an advantage by patients, technologists, interpreting and referring physicians, nurses and hospital management. Simultaneous imaging has the potential advantages of precise pixel registration and artifacts, if present, are identical in both thallium and sestamibi, and require only one set of imaging. Also, there are some disadvantages of spillover of activity from the Tc-99m to the Tl-201 window. Fortunately, despite this problem it can be overcome. Separate acquisition dual isotope also has some disadvantages. Difference in defect resolution in attenuation and scatter between T-201 and Tc-99m sestamibi potentially results in interpretation problems. But, studies about cost-effectiveness of dual isotope imaging showed that some selective elimination of the rest studies may decrease the cost of the nuclear procedures and should be considered in the current care health system.

  10. Human whole body cold adaptation.

    NARCIS (Netherlands)

    Daanen, Hein A.M.; Van Marken Lichtenbelt, Wouter D.

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced

  11. The bird's-eye views of the whole body bone scans

    Energy Technology Data Exchange (ETDEWEB)

    Machida, K; Akaike, A; Hayashi, S; Watari, T; Yasukochi, H [Tokyo Univ. (Japan). Faculty of Medicine

    1975-07-01

    Using a newly developed whole body gamma scanner (Toshiba-RDA-601), the authors recorded whole body bone scans in 5 patients (two normal, osteomalacia, bone metastases of prostate cancer and bone metastases of breast cancer), and compared the regular scintiscans with those of bird's-eye view images which were made with the data processor of the scanner. The scans were started about 2 hours after intravenous injection of 3 to 8 mCi of sup(99m)Tc-monofluorophosphate stannous fluoride. The recorded bird's-eye view scans displayed the skeletal system vividly as they were, and the distribution of radioactivity semiquantitatively. It was concluded that the bird'eye view scan is superior to the regular scan, in view of the point that it expresses the distribution of radioactivity semiquantitatively and enables one to know the amount of abnormally accumulated radioactivities by measuring the height of the peak of the diseased area, although this is very difficult in the regular scan. More clinical studies are needed in order to determine which is better for detecting abnormal part clinically.

  12. Whole body cardiovascular magnetic resonance imaging to stratify symptomatic and asymptomatic atherosclerotic burden in patients with isolated cardiovascular disease

    International Nuclear Information System (INIS)

    Weir-McCall, Jonathan R.; Duce, Suzanne L.; Gandy, Stephen J.; Matthew, Shona Z.; Martin, Patricia; Cassidy, Deirdre B.; McCormick, Lynne; Belch, Jill J. F.; Struthers, Allan D.; Colhoun, Helen M.; Houston, J. Graeme

    2016-01-01

    The aim of this study was to use whole body cardiovascular magnetic resonance imaging (WB CVMR) to assess the heart and arterial network in a single examination, so as to describe the burden of atherosclerosis and subclinical disease in participants with symptomatic single site vascular disease. 64 patients with a history of symptomatic single site vascular disease (38 coronary artery disease (CAD), 9 cerebrovascular disease, 17 peripheral arterial disease (PAD)) underwent whole body angiogram and cardiac MR in a 3 T scanner. The arterial tree was subdivided into 31 segments and each scored according to the degree of stenosis. From this a standardised atheroma score (SAS) was calculated. Cine and late gadolinium enhancement images of the left ventricle were obtained. Asymptomatic atherosclerotic disease with greater than 50 % stenosis in arteries other than that responsible for their presenting complain was detected in 37 % of CAD, 33 % of cerebrovascular and 47 % of PAD patients. Unrecognised myocardial infarcts were observed in 29 % of PAD patients. SAS was significantly higher in PAD patients 24 (17.5-30.5) compared to CAD 4 (2–11.25) or cerebrovascular disease patients 6 (2-10) (ANCOVA p < 0.001). Standardised atheroma score positively correlated with age (β 0.36 p = 0.002), smoking status (β 0.34 p = 0.002), and LV mass (β -0.61 p = 0.001) on multiple linear regression. WB CVMR is an effective method for the stratification of cardiovascular disease. The high prevalence of asymptomatic arterial disease, and silent myocardial infarctions, particularly in the peripheral arterial disease group, demonstrates the importance of a systematic approach to the assessment of cardiovascular disease

  13. Radiometric titration of thallium(III) with EDTA

    International Nuclear Information System (INIS)

    Rao, V.R.S.; Pulla Rao, Ch.; Tataiah, G.

    1978-01-01

    Radioactive solutions containing very small amounts of thallium(III) can be determined by radiometric titration using ammonia as hydrolysing agent. Aqueous solution of thallium(I) (both inactive and radioactive) is treated with bromine water till the appearance of the brown colour of bromine, and the solution is warmed to 80 deg C to expel the excess bromine. By this procedure all thallium(I) is quantitatively oxidised to thallium(III). An aqueous solution of ammonia is added to precipitate thallium(III) as thallic oxide. It is then filtered, washed with water to free it from bromide and then dissolved in 2N HCl and the solution is then standardised. 2 ml of this solution is transferred to a 20 ml volumetric flask, 1 ml of radioactive thallium(III) solution to be standardised is added as well as incremental amounts of EDTA solution and mixed thoroughly. Uncomplexed thallium(III) is then precipitated by the addition of an ammonia solution and diluted to 20 ml. Required amount of this mixture is centrifuged. The beta activity of the supernatant aliquot is measured using a GM counter. Quantitative determination of Tl(III) in the range of 1-10 μM can be carried out. The interference of cations such as Au(III), iron(III), Ga(III) can be eliminated by pretreatment of the Tl(III) solution before carrying out radiometric titration. The results obtained are reproducible and accurate to +-3%. (T.I.)

  14. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Pil-Hyun [Yonsei University, Wonju (Korea, Republic of); Wonju Christian Hospital, Wonju (Korea, Republic of); Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong [Yonsei University, Wonju (Korea, Republic of); Lee, Won-Hyung; Jeon, Sung-Su [Wonju Christian Hospital, Wonju (Korea, Republic of)

    2012-06-15

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  15. Whole-body CT in polytrauma patients: The effect of arm position on abdominal image quality when using a human phantom

    Science.gov (United States)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-06-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  16. Whole-body CT in polytrauma patients: the effect of arm position on abdominal image quality when using a human phantom

    International Nuclear Information System (INIS)

    Jeon, Pil-Hyun; Kim, Hee-Joung; Lee, Chang-Lae; Kim, Dae-Hong; Lee, Won-Hyung; Jeon, Sung-Su

    2012-01-01

    For a considerable number of emergency computed tomography (CT) scans, patients are unable to position their arms above their head due to traumatic injuries. The arms-down position has been shown to reduce image quality with beam-hardening artifacts in the dorsal regions of the liver, spleen, and kidneys, rendering these images non-diagnostic. The purpose of this study was to evaluate the effect of arm position on the image quality in patients undergoing whole-body CT. We acquired CT scans with various acquisition parameters at voltages of 80, 120, and 140 kVp and an increasing tube current from 200 to 400 mAs in 50 mAs increments. The image noise and the contrast assessment were considered for quantitative analyses of the CT images. The image noise (IN), the contrast-to-noise ratio (CNR), the signal-to-noise ratio (SNR), and the coefficient of variation (COV) were evaluated. Quantitative analyses of the experiments were performed with CT scans representative of five different arm positions. Results of the CT scans acquired at 120 kVp and 250 mAs showed high image quality in patients with both arms raised above the head (SNR: 12.4, CNR: 10.9, and COV: 8.1) and both arms flexed at the elbows on the chest (SNR: 11.5, CNR: 10.2, and COV: 8.8) while the image quality significantly decreased with both arms in the down position (SNR: 9.1, CNR: 7.6, and COV: 11). Both arms raised, one arm raised, and both arms flexed improved the image quality compared to arms in the down position by reducing beam-hardening and streak artifacts caused by the arms being at the side of body. This study provides optimal methods for achieving higher image quality and lower noise in abdominal CT for trauma patients.

  17. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    International Nuclear Information System (INIS)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi

    1994-01-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of 99m Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, γ-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author)

  18. The usefulness of early whole body bone scintigraphy in the detection of bone metastasis from prostatic cancer

    Energy Technology Data Exchange (ETDEWEB)

    Otsuka, Nobuaki; Fukunaga, Masao; Furukawa, Yohji; Tanaka, Hiroyoshi [Kawasaki Medical School, Kurashiki, Okayama (Japan)

    1994-06-01

    Early whole body bone scintigraphy was performed on 25 patients with prostatic cancer (15 cases with bone metastases and 10 cases without bone metastasis) to obtain anterior and posterior whole body images five minutes after administration of [sup 99m]Tc-hydroxymethylene diphosphonate(HMDP). The results were compared with the findings of routine bone scintigraphy after three hours, and the usefulness of the above method for the diagnosis of bone metastasis from prostatic cancer was evaluated. In cases in which increased activity was found in the upper and lower lumbar vertebrae by routine bone scintigraphy but no abnormality was seen by early whole body bone scintigraphy, senile degenerative bone changes such as spondylosis deformance were observed by bone radiography. In cases with multiple bone metastases, abnormal multiple accumulations were found by both early whole body bone scintigraphy and routine bone scintigraphy. In addition, in cases showing super bone scan, high accumulation in the skeletal system had already been detected by early whole body bone scintigraphy. When the courses before and after treatment in nine cases of multiple bone metastases were passaged from the results of early whole body bone scintigraphy and from changes in tumor markers (prostatic specific antigen, [gamma]-semino protein and prostatic acid phosphatase), increased activity and the appearance of new hot spots as well as an increase in tumor markers were detected by early whole body scintigraphy in three of the four advanced cases, whereas decreased accumulations and a decrease in and normalization of tumor markers were observed in five improved cases. (author).

  19. Whole-body FDG PET-MR oncologic imaging: pitfalls in clinical interpretation related to inaccurate MR-based attenuation correction.

    Science.gov (United States)

    Attenberger, Ulrike; Catana, Ciprian; Chandarana, Hersh; Catalano, Onofrio A; Friedman, Kent; Schonberg, Stefan A; Thrall, James; Salvatore, Marco; Rosen, Bruce R; Guimaraes, Alexander R

    2015-08-01

    Simultaneous data collection for positron emission tomography and magnetic resonance imaging (PET/MR) is now a reality. While the full benefits of concurrently acquiring PET and MR data and the potential added clinical value are still being evaluated, initial studies have identified several important potential pitfalls in the interpretation of fluorodeoxyglucose (FDG) PET/MRI in oncologic whole-body imaging, the majority of which being related to the errors in the attenuation maps created from the MR data. The purpose of this article was to present such pitfalls and artifacts using case examples, describe their etiology, and discuss strategies to overcome them. Using a case-based approach, we will illustrate artifacts related to (1) Inaccurate bone tissue segmentation; (2) Inaccurate air cavities segmentation; (3) Motion-induced misregistration; (4) RF coils in the PET field of view; (5) B0 field inhomogeneity; (6) B1 field inhomogeneity; (7) Metallic implants; (8) MR contrast agents.

  20. Simplified segmented human models for whole body and localised SAR evaluation of 20 MHz to 6 GHz electromagnetic field exposures

    International Nuclear Information System (INIS)

    Wu, T.; Shao, Q.; Yang, L.

    2013-01-01

    The digital human model is a key element in evaluating the electromagnetic field (EMF) exposure. This paper proposes the application of simplified segmented human models for EMF exposure compliance evaluation with the whole body and the localised limits. The method is based on the fact that most of the EMF power absorption is concentrated in several major tissues. Two kinds of human models were simply (the proposed method) and precisely segmented from two sets of whole body magnetic resonance imaging (MRI) scanned images. The whole body average-specific absorption rate (WBA-SAR) and the peak localised SAR averaging over 10 g tissues for the two kinds of models are calculated for various exposure configurations. The results confirmed the efficiency and the validity of the proposed method. The application as evaluating the MRI radiofrequency EMF exposure is also discussed in the paper. (authors)

  1. Thallium (III) salts utilization in organic synthesis. Part II

    International Nuclear Information System (INIS)

    Ferraz, H.M.C.

    1989-01-01

    The utilizations of thallium (III) salts in organic synthesis with carbonylic and acitylenic substrates are presented. The reactions of carbonylic substra3ts with kitones and the oxidation reactions of acetylenic substrates are shown. Others reactions including thallium (III) salts and non aromatic unsatured substracts, as cleasage of ethers and epoxide using thallium trinitrate, hydrazones treatments with thallium triacetates, etc, are also mentioned. (C.G.C.) [pt

  2. Exercise thallium-201 scintigraphy in men with nondiagnostic exercise electrocardiograms. Prognostic implications

    International Nuclear Information System (INIS)

    Iskandrian, A.S.; Hakki, A.H.; Kane-Marsch, S.

    1986-01-01

    We studied the prognostic value of exercise thallium-201 imaging in 196 men with suspected or known coronary artery disease who had nondiagnostic exercise electrocardiograms. The perfusion images in each of three projections were divided into three segments; each segment was assessed for perfusion defects (fixed or reversible). There were 12 cardiac events at a mean follow-up of 15 months (range, one to 66 months). Of those, five patients died of cardiac causes and seven had nonfatal acute myocardial infarctions (MIs). Only the number of perfusion defects significantly predicted cardiac events; clinical presentation, history of MI, presence of Q-wave MI, exercise duration, and exercise heart rate and double product did not predict cardiac events or add to information provided by the number of defects. Furthermore, actuarial life-table analysis showed that patients with three or more perfusion defects had significantly worse prognoses than patients with fewer than three defects. Exercise thallium-201 imaging helps in risk stratification of men with nondiagnostic exercise electrocardiograms

  3. Myocardial thallium-201 kinetics in normal and ischemic myocardium

    International Nuclear Information System (INIS)

    Grunwald, A.M.; Watson, D.D.; Holzgrefe, H.H. Jr.; Irving, J.F.; Beller, G.A.

    1981-01-01

    The net myocardial accumulation of thallium-201 after injection depends upon the net balance between continuing myocardial extraction from low levels of recirculating thallium in the blood compartment and the net rate of efflux of thallium from the myocardium into the extracardiac blood pool. These experiments were designed to measure separately the myocardial extraction and intrinsic myocardial efflux of thallium-201 at normal and at reduced rates of myocardial blood flow. The average myocardial extraction fraction at normal blood flow in 10 anesthetized dogs was 82 +/- 6% (+/- SD) at normal coronary arterial perfusion pressures and increased insignificantly, to 85 +/- 7%, at coronary perfusion pressures of 10--35 mm Hg. At normal coronary arterial perfusion pressures in 12 additional dogs, the intrinsic thallium washout in the absence of systemic recirculation had a half-time (T 1/2) of 54 +/- 7 minutes. The intrinsic cellular washout rate began to increase as distal perfusion pressures fell below 60 mm Hg and increased markedly to a T 1/2 of 300 minutes at perfusion pressures of 25--30 mm Hg. A second, more rapid component of intrinsic thallium washout (T 1/2 2.5 minutes) representing approximately 7% of the total initially extracted myocardial thallium was observed. The faster washout component is presumed to be due to washout of interstitial thallium unextracted by myocardial cells, whereas the slower component is presumed due to intracellular washout. The net clearance time of thallium measured after i.v. injection is much longer than the intrinsic myocardial cellular washout rate because of continuous replacement of myocardial thallium from systemic recirculation. Myocardial redistribution of thallium-201 in states of chronically reduced perfusion cannot be the result of increased myocardial extraction efficiency, but rather, is the result of the slower intrinsic cellular washout rate at reduced perfusion levels

  4. Accuracy and reproducibility of adipose tissue measurements in young infants by whole body magnetic resonance imaging.

    Science.gov (United States)

    Bauer, Jan Stefan; Noël, Peter Benjamin; Vollhardt, Christiane; Much, Daniela; Degirmenci, Saliha; Brunner, Stefanie; Rummeny, Ernst Josef; Hauner, Hans

    2015-01-01

    MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo. MR images of ten phantoms simulating subcutaneous fat of an infant's torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE) sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days). This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence. In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility. With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy.

  5. Accuracy and reproducibility of adipose tissue measurements in young infants by whole body magnetic resonance imaging.

    Directory of Open Access Journals (Sweden)

    Jan Stefan Bauer

    Full Text Available MR might be well suited to obtain reproducible and accurate measures of fat tissues in infants. This study evaluates MR-measurements of adipose tissue in young infants in vitro and in vivo.MR images of ten phantoms simulating subcutaneous fat of an infant's torso were obtained using a 1.5T MR scanner with and without simulated breathing. Scans consisted of a cartesian water-suppression turbo spin echo (wsTSE sequence, and a PROPELLER wsTSE sequence. Fat volume was quantified directly and by MR imaging using k-means clustering and threshold-based segmentation procedures to calculate accuracy in vitro. Whole body MR was obtained in sleeping young infants (average age 67±30 days. This study was approved by the local review board. All parents gave written informed consent. To obtain reproducibility in vivo, cartesian and PROPELLER wsTSE sequences were repeated in seven and four young infants, respectively. Overall, 21 repetitions were performed for the cartesian sequence and 13 repetitions for the PROPELLER sequence.In vitro accuracy errors depended on the chosen segmentation procedure, ranging from 5.4% to 76%, while the sequence showed no significant influence. Artificial breathing increased the minimal accuracy error to 9.1%. In vivo reproducibility errors for total fat volume of the sleeping infants ranged from 2.6% to 3.4%. Neither segmentation nor sequence significantly influenced reproducibility.With both cartesian and PROPELLER sequences an accurate and reproducible measure of body fat was achieved. Adequate segmentation was mandatory for high accuracy.

  6. [Performance of Thallium 201 rest-redistribution spect to predict viability in recent myocardial infarction].

    Science.gov (United States)

    Coll, Claudia; González, Patricio; Massardo, Teresa; Sierralta, Paulina; Humeres, Pamela; Jofré, Josefina; Yovanovich, Jorge; Aramburú, Ivonne; Brugère, Solange; Chamorro, Hernán; Ramírez, Alfredo; Kunstmann, Sonia; López, Héctor

    2002-03-01

    The detection of viability after acute myocardial infarction is primordial to select the most appropriate therapy, to decrease cardiac events and abnormal remodeling. Thallium201 SPECT is one of the radionuclide techniques used to detect viability. To evaluate the use of Thallium201 rest-redistribution SPECT to detect myocardial viability in reperfused patients after a recent myocardial infarction. Forty one patients with up to of 24 days of evolution of a myocardial infarction were studied. All had angiographically demonstrated coronary artery disease and were subjected to a successful thrombolysis, angioplasty or bypass grafting. SPECT Thallium201 images were acquired at rest and after 4 h of redistribution. These results were compared with variations in wall motion score, studied at baseline and after 3 or 4 months with echocardiography. The sensitivity of rest-redistribution Thallium201 SPECT, to predict recovery of wall motion was 91% when patient analysis was performed and 79% when segmental analysis was done in the culprit region. The figures for specificity were 56 and 73% respectively. Rest-distribution Thallium201 SPECT has an excellent sensitivity to predict myocardial viability in recent myocardial infarction. The data obtained in this study is similar to that reported for chronic coronary artery disease.

  7. Thallium-201 scintigraphy in diagnosis of coronary stenosis

    International Nuclear Information System (INIS)

    Corne, R.A.; Gotsman, M.S.; Weiss, A.; Enlander, D.; Samuels, L.D.; Salomon, J.A.; Warshaw, B.; Atlan, H.

    1979-01-01

    The sensitivity of rest and exercise thallium-201 scintigraphy for the detection of significant coronary artery disease and myocardial ischaemia was compared with rest and exercise electrocardiography in 46 patients with chest pain. Of 26 patients with greater that 70 per cent coronary stenosis, 16 had abnormal rest thallium-201 scintigrams and 13 had Q waves. Myocardial perfusion defects in the resting scintigram correlated very well with evidence of previous myocardial infarction (16 of 17 patients, 94%) significant Q waves were present in 13 of these 17 patients (76%). After exercise, abnormal thallium-201 scintigrams consistent with ischaemia were found in 21 patients (81%). Abnormal exercise electrocardiograms were present in 15 patients (58%). The combination of abnormal exercise thallium-201 scintigrams or exercise electrocardiograms (23/26, 88%) exceeded abnormal exercise electrocardiograms alone (15/26, 58%). The two procedures were thus complementary. Abnormal rest or exercise thallium-201 scintigrams were obtained in 25/26 patients (96%) compared with abnormal rest or exercise electrocardiograms in 21/26 patients (84%). Twenty patients with less than 50 per cent coronary stenosis had normal rest thallium-201 scintigrams and no Q waves. Two had abnormal exercise thallium-201 scintigrams and 7 had abnormal exercise electrocardiograms. Thus,exercise thallium scintigraphy has higher sensitivity than exercise electrocardiography in detecting exercise induced ischaemia and is more specific. Scintigraphy appears to have a higher sensitivity than electrocardiography in detecting coronary artery disease. (author)

  8. Whole body MRI, including diffusion-weighted imaging in follow-up of patients with testicular cancer.

    Science.gov (United States)

    Mosavi, Firas; Laurell, Anna; Ahlström, Håkan

    2015-11-01

    Whole body (WB) magnetic resonance imaging (MRI), including diffusion-weighted imaging (DWI) has become increasingly utilized in cancer imaging, yet the clinical utility of these techniques in follow-up of testicular cancer patients has not been evaluated. The purpose of this study was to evaluate the feasibility of WB MRI with continuous table movement (CTM) technique, including multistep DWI in follow-up of patients with testicular cancer. WB MRI including DWI was performed in follow-up of 71 consecutive patients (median age, 37 years; range 19-84) with histologically confirmed testicular cancer. WB MRI protocol included axial T1-Dixon and T2-BLADE sequences using CTM technique. Furthermore, multi-step DWI was performed using b-value 50 and 1000 s/mm(2). One criterion for feasibility was patient tolerance and satisfactory image quality. Another criterion was the accuracy in detection of any pathological mass, compared to standard of reference. Signal intensity in DWI was used for evaluation of residual mass activity. Clinical, laboratory and imaging follow-up were applied as standard of reference for the evaluation of WB MRI. WB MRI was tolerated in nearly all patients (69/71 patients, 97%) and the image quality was satisfactory. Metal artifacts deteriorated the image quality in six patients, but it did not influence the overall results. No case of clinical relapse was observed during the follow-up time. There was a good agreement between conventional WB MRI and standard of reference in all patients. Three patients showed residual masses and DWI signal was not restricted in these patients. Furthermore, DWI showed abnormally high signal intensity in a normal-sized retroperitoneal lymph node indicating metastasis. The subsequent (18)F-FDG PET/CT could verify the finding. WB MRI with CTM technique including multi-step DWI is feasible in follow-up of patients with testicular cancer. DWI may contribute to important added-value data to conventional MRI sequences

  9. Thallium-201 myocardial perfusion imaging at rest and during exercise. Comparative sensitivity to electrocardiography in coronary artery disease

    International Nuclear Information System (INIS)

    Bailey, I.K.; Griffith, L.S.C.; Rouleau, J.; Strauss, H.W.; Pitt, B.

    1977-01-01

    The sensitivity of myocardial perfusion imaging (MPI) using thallium-201 injected both at rest and during peak exercise was compared to simultaneously recorded 12 lead electrocardiography (ECG) for the detection of transient ischemia in 20 normal subjects and 63 patients with coronary artery disease (CAD). No significant perfusion defects or ECG changes were seen on either the rest or exercise studies in any of the normal subjects. Fifty-six percent of patients with CAD developed new perfusion defects with exercise compared to 38 percent who developed ischemic ST-segment depression (P < 0.02). However, when chest pain and/or ST depression were considered indices of ischemia, the sensitivity of exercise testing and thallium-201 MPI was similar. The increased sensitivity of MPI compared to ST-segment depression on the ECG was due to patients with baseline ECG abnormalities and those who failed to achieve 85 percent of predicted maximum heart rate with exercise. Analysis of the exercise results according to the extent of coronary artery disease revealed a progressive increase in both positive ECGs and MPI with the number of vessels involved. In patients with single vessel disease the MPI was more sensitive than the ECG (P < 0.02). The combination of the rest and exercise ECG, MPI and chest pain during exercise failed to identify 11 percent of patients with CAD. Exercise thallium-201 MPI is a useful adjunct to conventional exercise testing particularly when evaluating patients with abnormal resting ECGs, those who develop ventricular conduction defects or arrhythmias during exercise, and those who fail to achieve their predicted heart rate because of fatigue or breathlessness

  10. Rest thallium-201 myocardial perfusion imaging in a patient with leukaemic infiltration of the heart

    International Nuclear Information System (INIS)

    Civelek, A.C.; Camargo, E.E.; Links, J.M.; Brinker, J.A.; Wagner, H.N. Jr.

    1992-01-01

    Despite the high incidence of leukaemic infiltration of the heart, only 8 cases of atrioventricular block due to leukemia have been reported in the literature. Improvement in the heart block associated with disappearance of the leukaemic infiltrate has not been reported. A rest thallium-201 study was used in a 65-year-old man to demonstrate leukaemic infiltration of the heart which was associated with complete heart block. After chemotherapy, when the tumour burden was reduced and the leukaemia in remission, his heart block resolved, and a follow-up thallium scan was normal. (orig.)

  11. Linear Representation of Emotions in Whole Persons by Combining Facial and Bodily Expressions in the Extrastriate Body Area

    Science.gov (United States)

    Yang, Xiaoli; Xu, Junhai; Cao, Linjing; Li, Xianglin; Wang, Peiyuan; Wang, Bin; Liu, Baolin

    2018-01-01

    Our human brain can rapidly and effortlessly perceive a person’s emotional state by integrating the isolated emotional faces and bodies into a whole. Behavioral studies have suggested that the human brain encodes whole persons in a holistic rather than part-based manner. Neuroimaging studies have also shown that body-selective areas prefer whole persons to the sum of their parts. The body-selective areas played a crucial role in representing the relationships between emotions expressed by different parts. However, it remains unclear in which regions the perception of whole persons is represented by a combination of faces and bodies, and to what extent the combination can be influenced by the whole person’s emotions. In the present study, functional magnetic resonance imaging data were collected when participants performed an emotion distinction task. Multi-voxel pattern analysis was conducted to examine how the whole person-evoked responses were associated with the face- and body-evoked responses in several specific brain areas. We found that in the extrastriate body area (EBA), the whole person patterns were most closely correlated with weighted sums of face and body patterns, using different weights for happy expressions but equal weights for angry and fearful ones. These results were unique for the EBA. Our findings tentatively support the idea that the whole person patterns are represented in a part-based manner in the EBA, and modulated by emotions. These data will further our understanding of the neural mechanism underlying perceiving emotional persons. PMID:29375348

  12. A fatal case of thallium toxicity: challenges in management.

    Science.gov (United States)

    Riyaz, R; Pandalai, S L; Schwartz, M; Kazzi, Z N

    2013-03-01

    Thallium is a highly toxic compound and is occasionally involved in intentional overdoses or criminal poisonings. Accidental poisonings also occur, but are increasingly rare owing to restricted use and availability of thallium. We report a fatal suicidal ingestion of thallium sulfate rodenticide in which multi-dose activated charcoal (MDAC) and Prussian Blue (PB) were both used without changing the outcome. A 36 year old man ingested an unknown amount of thallium sulfate grains from an old rodenticide bottle. He presented to an emergency department (ED) 45 minutes later with abdominal pain and vomiting. On examination he was agitated with a blood pressure of 141/60 mmHg and a heart rate of 146 beats per minute (bpm). He received MDAC during his initial ED management and was started on PB 18 hours post arrival; he was intubated on the following day for airway protection. The patient continued to be tachycardic and hypertensive and subsequently developed renal failure. On hospital day three, the patient developed hypotension that did not respond to fluids. The patient required vasopressors and was transferred to a tertiary care center to undergo continuous renal replacement therapy (CRRT). The patient died shortly after his transfer. His last blood thallium concentration was 5369 mcg/L, a spot urine thallium >2000 mcg/L, and a 24- hour urine thallium was >2000 mcg/L. Though extremely rare, thallium intoxication can be lethal despite early administration of MDAC and use of Prussian blue therapy. Rapid initiation of hemodialysis can be considered in cases of severe thallium poisoning, to remove additional thallium, to correct acid-base disturbance, or to improve renal function.

  13. Comparative study of body surface isopotential map, left ventriculogram and thallium-201 myocardial scintigram in patients with old lateral myocardial infarction

    International Nuclear Information System (INIS)

    Matsumoto, Naoyuki

    1988-01-01

    In 16 patients with old lateral myocardial infarction, body surface isopotential maps and 12 lead electrocardiograms were compared with left ventriculographic findings. In addition 8 of these subjects were performed thallium-201 myocardial scintigraphy in order to determine the location and extent of myocardial necrosis. Common 12 lead electrocardiographic findings of the subjects were initial Q waves more than 30 msec and inverted T waves in only aVL lead. The patients were classified into 4 groups according to the location and extent of ventricular wall motion abnormalities group I (6 cases) showed hypokinesis in the anterior segment, group II (5 cases): akinesis in the anterior segment and hypokinesis in the seg. 6, group III (4 cases): hypokinesis in the anterior segment and seg. 7, group IV (1 case): hypokinesis in the anterior segment and seg. 4, 7. And each of the 4 groups demonstrated characteristic findings of surface isopotential maps. Group II with coexisting hypokinesis in the seg. 6 showed surface isopotential maps additional pattern of anterior myocardial infarction, and group III with coexisting hypokinesis in the seg. 7 showed additional patterns of posterior myocardial infarction. The classification according to the abnormality of ventricular wall motion was also conformed with the thallium-201 myocardial scintigraphic findings except one case. These results suggest that body surface isopotential map is more useful than the 12 lead electrocardiogram in detecting the location and extent of left ventricular wall motion abnormality in patients with old lateral myocardial infarction. (author) 53 refs

  14. Mechanism underlying the absence of ischemic changes on the exercise electrocardiogram in patients with abnormal exercise thallium-201 imaging and coronary artery disease

    International Nuclear Information System (INIS)

    Coplan, N.L.; Horowitz, S.F.; Hoffman, D.P.; Goldman, M.E.; Machac, J.

    1985-01-01

    Patients with coronary artery disease may have reversible abnormalities on a thallium myocardial perfusion study without simultaneous ischemic changes on the exercise electrocardiogram, but the mechanisms responsible for this disparity have not been fully elucidated. A group of 37 patients with angiographically demonstrated coronary artery disease and abnormal thallium perfusion imaging were divided into two groups on the basis of their exercise electrocardiographic ST segment response. Thirteen patients (Group A) had no significant electrocardiographic changes with exercise, while 24 patients (Group B) had ST changes consistent with ischemia during the test. There were no significant differences in clinical or angiographic characteristics between the two groups. Stress test results showed a similar mean duration of exercise in the two groups, but the patients in Group A achieved a significantly lower mean maximal heart rate and mean maximal double product. These results suggest that exercise thallium-electrocardiogram discordance is mediated by the level of myocardial workload achieved. An abnormal perfusion scan accompanying an exercise electrocardiogram which does not demonstrate any ischemic ST change may occur when there is sufficient increase in myocardial oxygen demand to result in differential augmentation of myocardial blood flow, but insufficient imbalance of supply and demand to result in signs of ischemia on the surface electrocardiogram

  15. Human and animal studies: portals into the whole body and whole population response

    Science.gov (United States)

    Human and animal studies: portals into the whole body and whole population response Michael C. Madden1 and Brett Winters21US Environmental Protection Agency and 2University of North Carolina Human Studies Facility, Chapel Hill, North Carolina, USA Studies involving collection and...

  16. Effect of hypoxia on thallium kinetics in cultured chick myocardial cells

    International Nuclear Information System (INIS)

    Friedman, B.J.; Beihn, R.; Friedman, J.P.

    1987-01-01

    To assess the effect of hypoxia on cellular thallium-201 ( 201 Tl) uptake and washout independent of coronary flow, we studied thallium kinetics during normoxia and hypoxia in cultured chick ventricular cells. Monolayers of contracting ventricular cells grown on coverslips were placed in a chamber and perfused to asymptote with media containing 201 Tl. Perfusates were equilibrated with 5% CO 2 -95% air or 5% CO 2 -95% nitrogen for normoxia and hypoxia, respectively. Washout thallium kinetics were then observed during perfusion with unlabeled media. Twenty paired experiments were performed, randomly alternating the sequence of normoxia and hypoxia. Pharmacokinetics for thallium were determined by computer using standard formulae. Thallium uptake and washout were best described by assuming that intracellular thallium was contained within a single compartment. Cellular thallium uptake, as well as transfer rate constants for thallium uptake and for thallium washout during normoxia and hypoxia, were compared using paired t-tests. During normoxia and hypoxia, respectively, thallium uptake was 22 +/- 7% and 19 +/- 7% of asymptote (p less than 0.01); the compartmental rate constant for uptake by the cell was 0.16 +/- 0.07 min-1 and 0.15 +/- 0.06 min-1 (N.S.); and the transfer rate constant for washout from the cell was 0.26 +/- 0.06 min-1 and 0.23 +/- 0.05 min-1 (p less than 0.01). We conclude that there was a small (14%) decrease in thallium uptake during hypoxia. The rate of thallium uptake and washout was slightly less during hypoxia, although only the rate of washout was significantly less. These data show that cellular accumulation of thallium and the rate of washout of thallium were minimally decreased by hypoxia independent of blood flow

  17. Risk-benefit of dipyridamole loading thallium-201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Ueshima, Kenji; Ogiu, Naonori; Musha, Takehiko; Moriai, Naoki; Miyakawa, Tomohisa; Nakai, Kenji; Hiramori, Katsuhiko

    1995-01-01

    This study assessed the accuracy of dipyridamole-stressed thallium-201 scintigraphy in the detection of myocardial ischemia, as well as the associated complications and their background factors. Fifty consecutive patients (33 men and 17 women; a mean age of 67 years) unable to undergo exercise thallium imaging were examined. R waves on resting ECG, the occurrence of ischemic changes on exercise ECG, asynergy on left ventriculography and dobutamine-stressed two-dimensional echocardiography, uptake of FEG on PET, and coronary angiographic findings were comprehensively assessed to determine the accuracy of the present scintigraphy. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value were 60.4%, 94.2%, 89.7%, 83.0%, and 82.9%, respectively. These findings yielded satisfactory detectability of dipyridamole-stressed thallium-201 scintigraphy for myocardial ischemia. The present scintigraphy had a high sensitivity and specificity for the left anterior descending artery; however, it had a high specificity but low sensitivity for the other arteries. A majority of complications during the scintigraphy was transient, mild decrease in blood pressure, which was found especially when ischemia was present in the left circumflex artery and chest pain occurred during dipyridamole stress. Dipyridamole stress is considered to be contraindicated for patients with unstable angina. (N.K.)

  18. National survey of human body radioactivity measured by a mobile whole-body counter and installed whole-body counters

    International Nuclear Information System (INIS)

    Boddy, K.; Fenwick, J.D.; McKenzie, A.L.

    1989-05-01

    Body radioactivity in the general public has been measured in 2339 volunteers throughout the U.K. A mobile whole-body monitor visited collaborating Medical Physics Departments and data were also contributed by Medical Physics Departments possessing installed counters. Levels of body radiocaesium ranged from below detection level to 4149 Bq. Radiocaesium levels were normalised by dividing by the content of natural body potassium-40. In all cases, the dose rate to the body from radiocaesium was less than that from potassium-40. Radiocaesium levels were 2-3 times higher in N.W. England, Scotland and N. Wales than the rest of the country, but this factor is much less than the variation in deposition of Chernobyl radiocaesium. This discrepancy may be accounted for by the nationwide distribution of foodstuffs. At all sites where volunteers were monitored, the ratio of caesium-137/caesium-134 was consistent with a radiocaesium intake attributable primarily to fallout from the Chernobyl fire. (author)

  19. Predicting the extent and location of coronary artery disease during the early postinfarction period by quantitative thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Gibson, R.S.; Taylor, G.J.; Watson, D.D.; Stebbins, P.T.; Martin, R.P.; Crampton, R.S.; Beller, G.A.

    1981-01-01

    The ability of quantitative thallium-201 scintigraphy to predict the extent and location of coronary artery disease before hospital discharge after acute myocardial infarction was evaluated in 52 patients. All patients underwent coronary angiography and serial thallium-201 imaging either at rest or after submaximal exercise stress. Two or three vessel disease was designated if abnormal thallium-201 uptake or washout patterns, or both, were seen in two or three vascular segments, respectively. Of 156 vessels analyzed in the 52 patients, 91 stenoses of 70 percent or greater were found by angiography. Seventy-four of these were predicted by scintigraphy. The specificity of scintigraphy for identifying vessel stenoses was 92 percent. Sensitivity for detecting and localizing stenoses supplying an infarct zone was 96 percent compared with 62 percent for stenoses supplying myocardium remote from the acute infarct. Perfusion abnormalities were more frequently seen in the distribution of vessels with severe stenoses than in those with moderate stenoses. Scintigraphy detected a greater proportion of left anterior descending and right coronary arterial stenoses than circumflex stenoses. In the 42 patients who underwent submaximal exercise testing, multivariate analysis of 23 clinical and laboratory variables identified multiple thallium-201 defects as the best predictor of multivessel disease. The predictive accuracy of exercise-induced S-T segment depression was only 45 percent compared with 88 percent for thallium-201 scintigraphy. Thallium-201 imaging at rest is reliable in assessing the extent of coronary disease in hospitalized patients who cannot undergo exercise testing because of unstable angina, uncompensated heart failure, poorly controlled arrhythmias or physical limitations

  20. Role of combined DWIBS/3D-CE-T1w whole-body MRI in tumor staging: Comparison with PET-CT

    International Nuclear Information System (INIS)

    Manenti, Guglielmo; Cicciò, Carmelo; Squillaci, Ettore; Strigari, Lidia; Calabria, Ferdinando; Danieli, Roberta

    2012-01-01

    Objectives: To assess the diagnostic performance of whole-body magnetic resonance imaging (WB-MRI) by diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) in malignant tumor detection and the potential diagnostic advantages in generating fused DWIBS/3D-contrast enhanced T1w (3D-CE-T1w) images. Methods: 45 cancer patients underwent 18F-FDG PET-CT and WB-MRI for staging purpose. Fused DWIBS/3D-CE T1w images were generated off-line. 3D-CE-T1w, DWIBS images alone and fused with 3D-CE T1w were compared by two readers groups for detection of primary diseases and local/distant metastases. Diagnostic performance between the three WB-MRI data sets was assessed using receiver operating characteristic (ROC) curve analysis. Imaging exams and histopathological results were used as standard of references. Results: Areas under the ROC curves of DWIBS vs. 3D-CE-T1w vs. both sequences in fused fashion were 0.97, 0.978, and 1.00, respectively. The diagnostic performance in tumor detection of fused DWIBS/3D-CE-T1w images were statistically superior to DWIBS (p < 0.001) and 3D-CE-T1w (p ≤ 0.002); while the difference between DWIBS and 3D-CE-T1w did not show statistical significance difference. Detection rates of malignancy did not differ between WB-MRI with DWIBS and 18F-FDG PET-CT. Conclusion: WB-MRI with DWIBS is to be considered as alternative tool to conventional whole-body methods for tumor staging and during follow-up in cancer patients.

  1. whole body vibration and spinal stabilisation

    African Journals Online (AJOL)

    A range of exercise modalities is used in the rehabilitation of indi- viduals with chronic lower ... effects of whole body vibration (WBV) therapy and conventional ... with musculoskeletal, sensory, emotional, cognitive and behavioural components ...

  2. AIDS-related Kaposi sarcoma: findings on thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Lee, V.W.; Rosen, M.P.; Baum, A.; Cohen, S.E.; Cooley, T.P.; Liebman, H.A.

    1988-01-01

    No simple, noninvasive method is available for evaluating extracutaneous Kaposi sarcoma in AIDS patients or for following the tumor's response to treatment. We report our preliminary experience with thallium-201 scintigraphy in nine AIDS patients with proved Kaposi sarcoma. Eight of the nine had abnormal uptake of the radionuclide in skin, lymph nodes, oral cavity, vagina, and lungs. Only four of the nine had cutaneous Kaposi sarcoma at the time of scanning. All cutaneous and mucosal lesions were thallium avid. Two of the six patients with thallium-avid nodes underwent nodal biopsy. Both biopsies confirmed the diagnosis of Kaposi sarcoma. Cutaneous Kaposi sarcoma developed later in one of these patients, showing the efficacy of thallium scintigraphy for the early detection of extracutaneous lesions. These preliminary results show thallium avidity in Kaposi sarcoma involving the skin and various extracutaneous sites (lymph nodes, lung, mucosa, and vagina). Thallium scintigraphy is a potentially useful procedure for detecting extracutaneous Kaposi sarcoma in AIDS patients

  3. Comparison of exercise radionuclide angiography with thallium SPECT imaging for detection of significant narrowing of the left circumflex coronary artery

    International Nuclear Information System (INIS)

    Dilsizian, V.; Perrone-Filardi, P.; Cannon, R.O. III; Freedman, N.M.; Bacharach, S.L.; Bonow, R.O.

    1991-01-01

    Although quantitation of exercise thallium tomograms has enhanced the noninvasive diagnosis and localization of coronary artery disease, the detection of stenosis of the left circumflex coronary artery remains suboptimal. Because posterolateral regional wall motion during exercise is well assessed by radionuclide angiography, this study determined whether regional dysfunction of the posterolateral wall during exercise radionuclide angiography is more sensitive in identifying left circumflex disease than thallium perfusion abnormalities assessed by single-photon emission computed tomography (SPECT). One hundred ten consecutive patients with CAD were studied, of whom 70 had a significant stenosis of the left circumflex coronary artery or a major obtuse marginal branch. Both regional function and segmental thallium activity of the posterolateral wall were assessed using visual and quantitative analysis. Left ventricular regional function was assessed objectively by dividing the left ventricular region of interest into 20 sectors; the 8 sectors corresponding to the posterolateral free wall were used to assess function in the left circumflex artery distribution. Similarly, using circumferential profile analysis of short-axis thallium tomograms, left ventricular myocardial activity was subdivided into 64 sectors; the 16 sectors corresponding to the posterolateral region were used to assess thallium perfusion abnormalities in the left circumflex artery territory. Qualitative posterolateral wall motion analysis detected 76% of patients with left circumflex coronary artery stenosis, with a specificity of 83%, compared with only 44% by qualitative thallium tomography (p less than 0.001) and a specificity of 92%

  4. Whole-body irradiation in case of malignant lymphomas of low malignancy

    Energy Technology Data Exchange (ETDEWEB)

    Labedzki, L; Schmidt, R E; Hartlapp, J H; Illiger, H J; Frommhold, H; Boldt, I

    1982-04-01

    27 consecutive patients with malignant lymphomas were submittet to whole-body irradiations with doses of 0.5 to 3 Gy. Among these patients ten had been treated before. There were two complete and 16 partial remissions. The condition of five patients could not be considerably improved. Four patients showed a tumor progression during the time of bone marrow depression. The remission period was 11.5 (3 to 22 +) months. The hematologic side effects were considerable; in ten cases, the whole-body irradiation could not be continued because of a thrombocytopenia or an aplastic syndrome. A remarkable fact was the appearance of symptoms similar to that of lupus erythematodes in two patients. An inefficacy of whole-body irradiation did not exclude a response to subsequent chemotherapy. Our own experiences allow to make the following conclusion: in most of all patients with malignant lymphomas of low malignancy a measurable tumor reduction is achieved by whole-body irradiation. Because of the hematologic side effects a whole-body irradiation should be applied only in cases of malignant lymphomas of low malignancy the slow growth of which is proved by observation and which have not been treated before. The thrombocyte numbers should be above 100 000/..mu..l before therapy. Otherwise, the whole-body irradiation has to be stopped before the intended effective dose is reached because of an inevitably developing thrombocytopenia. A whole-body irradiation in case of a malignant lymphoma of low grade malignancy necessitates strict follow-up examinations conducted at regular intervals for a period of at least six weeks after the irradiation. The whole-body irradiation should never be applied as ultima ratio.

  5. Volumetry based biomarker speed of growth: Quantifying the change of total tumor volume in whole-body magnetic resonance imaging over time improves risk stratification of smoldering multiple myeloma patients.

    Science.gov (United States)

    Wennmann, Markus; Kintzelé, Laurent; Piraud, Marie; Menze, Bjoern H; Hielscher, Thomas; Hofmanninger, Johannes; Wagner, Barbara; Kauczor, Hans-Ulrich; Merz, Maximilian; Hillengass, Jens; Langs, Georg; Weber, Marc-André

    2018-05-18

    The purpose of this study was to improve risk stratification of smoldering multiple myeloma patients, introducing new 3D-volumetry based imaging biomarkers derived from whole-body MRI. Two-hundred twenty whole-body MRIs from 63 patients with smoldering multiple myeloma were retrospectively analyzed and all focal lesions >5mm were manually segmented for volume quantification. The imaging biomarkers total tumor volume, speed of growth (development of the total tumor volume over time), number of focal lesions, development of the number of focal lesions over time and the recent imaging biomarker '>1 focal lesion' of the International Myeloma Working Group were compared, taking 2-year progression rate, sensitivity and false positive rate into account. Speed of growth, using a cutoff of 114mm 3 /month, was able to isolate a high-risk group with a 2-year progression rate of 82.5%. Additionally, it showed by far the highest sensitivity in this study and in comparison to other biomarkers in the literature, detecting 63.2% of patients who progress within 2 years. Furthermore, its false positive rate (8.7%) was much lower compared to the recent imaging biomarker '>1 focal lesion' of the International Myeloma Working Group. Therefore, speed of growth is the preferable imaging biomarker for risk stratification of smoldering multiple myeloma patients.

  6. Whole-body effective half-lives for radiolabeled antibodies and related issues

    International Nuclear Information System (INIS)

    Kaurin, D.G.L.; Carsten, A.L.; Baum, J.W.; Barber, D.E.

    1996-08-01

    Radiolabeled antibodies (RABs) are being developed and used in medical imaging and therapy in rapidly increasing numbers. Data on the whole body half effective half-lives were calculated from external dose rates obtained from attending physicians and radiation safety officers at participating institutions. Calculations were made using exponential regression analysis of data from patients receiving single and multiple administrations. Theses data were analyzed on the basis of age, sex, isotope label, radiation energy, antibody type, disease treated, administration method, and number of administrations

  7. Whole-body effective half-lives for radiolabeled antibodies and related issues

    Energy Technology Data Exchange (ETDEWEB)

    Kaurin, D.G.L.; Carsten, A.L.; Baum, J.W.; Barber, D.E.

    1996-08-01

    Radiolabeled antibodies (RABs) are being developed and used in medical imaging and therapy in rapidly increasing numbers. Data on the whole body half effective half-lives were calculated from external dose rates obtained from attending physicians and radiation safety officers at participating institutions. Calculations were made using exponential regression analysis of data from patients receiving single and multiple administrations. Theses data were analyzed on the basis of age, sex, isotope label, radiation energy, antibody type, disease treated, administration method, and number of administrations.

  8. Whole-body impedance control of wheeled humanoid robots

    CERN Document Server

    Dietrich, Alexander

    2016-01-01

    Introducing mobile humanoid robots into human environments requires the systems to physically interact and execute multiple concurrent tasks. The monograph at hand presents a whole-body torque controller for dexterous and safe robotic manipulation. This control approach enables a mobile humanoid robot to simultaneously meet several control objectives with different pre-defined levels of priority, while providing the skills for compliant physical contacts with humans and the environment. After a general introduction into the topic of whole-body control, several essential reactive tasks are developed to extend the repertoire of robotic control objectives. Additionally, the classical Cartesian impedance is extended to the case of mobile robots. All of these tasks are then combined and integrated into an overall, priority-based control law. Besides the experimental validation of the approach, the formal proof of asymptotic stability for this hierarchical controller is presented. By interconnecting the whole-body ...

  9. Isolation of radioactive thallium from mercury targets

    International Nuclear Information System (INIS)

    Sevast'yanova, A.S.; Kozlova, M.D.; Malinin, A.B.; Kurenkov, N.V.

    1989-01-01

    The extraction method of thallium-201, 202, 200 separation from mercury target irradiated by protons is suggested. Tl + in sulfuric acid solution prepared after Hg-target treatment with the sulfuric acid was oxidized up to Tl 3+ with hydrogen peroxide and then it was extracted with butylacetate. Thallium was re-exrtacted by the sulfurous acid solution in the presence of CCl 4 , and Tl 3+ was recovered up to Tl + . The method permits to separate thallium with chemical yield nor less than 95 %. 2 refs

  10. Extracorporeal treatment for thallium poisoning

    DEFF Research Database (Denmark)

    Ghannoum, Marc; Nolin, Thomas D; Goldfarb, David S

    2012-01-01

    The EXtracorporeal TReatments In Poisoning (EXTRIP) workgroup was formed to provide recommendations on the use of extracorporeal treatment (ECTR) in poisoning. To test and validate its methods, the workgroup reviewed data for thallium (Tl).......The EXtracorporeal TReatments In Poisoning (EXTRIP) workgroup was formed to provide recommendations on the use of extracorporeal treatment (ECTR) in poisoning. To test and validate its methods, the workgroup reviewed data for thallium (Tl)....

  11. Whole body X-ray CT scanner SCT-3000T series

    International Nuclear Information System (INIS)

    Saida, Teruhiko; Takemura, Kunihiko; Suzuki, Satoru; Sato, Yukio; Kawamoto, Yasushi; Goto, Mitsuhiro; Mishina, Yukio

    1989-01-01

    The whole body CT scanner, SCT-3000T series which improve the patient through-put and the diagnostic capability, has been developed. In the SCT-3000T series CT scanners, the great reduction of the reconstruction time and the scan cycle time has been achieved by developing the special purpose hardwares for image reconstruction such as the fast front end processor, the intelligent buffer memory. In case of the SCT-3000TX routine conditions of operation, including 3.0 sec scan, table increment, image reconstruction and image filing, the scan cycle time is about 9 seconds which is the shortest value among the competitive models. Furthermore, the higher diagnostic capability has been provided with the system, by adopting the 1024 x 1024 display matrices, and by developing the diagnostic softwares such as 3-D display program, arbitrary curved plane MPR program, r-CBF measurement program and etc. (author)

  12. Sodium-23 MRI of whole spine at 3 Tesla using a 5-channel receive-only phased-array and a whole-body transmit resonator

    Energy Technology Data Exchange (ETDEWEB)

    Malzacher, Matthias; Kalayciyan, Raffi; Konstandin, Simon; Schad, Lothar R. [Heidelberg Univ., Mannheim (Germany). Computer Assisted Clinical Medicine; Haneder, Stefan [Heidelberg Univ., Mannheim (Germany). Clinical Radiology and Nuclear Medicine; University Hospital of Cologne, Koeln (Germany). Dept. of Radiology

    2016-05-01

    Sodium magnetic resonance imaging ({sup 23}Na MRI) is a unique and non-invasive imaging technique which provides important information on cellular level about the tissue of the human body. Several applications for {sup 23}Na MRI were investigated with regard to the examination of the tissue viability and functionality for example in the brain, the heart or the breast. The {sup 23}Na MRI technique can also be integrated as a potential monitoring instrument after radiotherapy or chemotherapy. The main contribution in this work was the adaptation of {sup 23}Na MRI for spine imaging, which can provide essential information on the integrity of the intervertebral disks with respect to the early detection of disk degeneration. In this work, a transmit-only receive-only dual resonator system was designed and developed to cover the whole human spine using {sup 23}Na MRI and increase the receive sensitivity. The resonator system consisted of an already presented {sup 23}Na whole-body resonator and a newly developed 5-channel receive-only phased-array. The resonator system was first validated using bench top and phantom measurements. A threefold SNR improvement at the depth of the spine (∝7 cm) over the whole-body resonator was achieved using the spine array. {sup 23}Na MR measurements of the human spine using the transmit-only receive-only resonator system were performed on a healthy volunteer within an acquisition time of 10 minutes. A density adapted 3D radial sequence was chosen with 6 mm isotropic resolution, 49 ms repetition time and a short echo time of 540 μs. Furthermore, it was possible to quantify the tissue sodium concentration in the intervertebral discs in the lumbar region (120 ms repetition time) using this setup.

  13. Commercial production of thallium-201 chloride

    International Nuclear Information System (INIS)

    Sokolov, S.V.; Volkova, N.M.; Skokov, V.S.

    1989-01-01

    Thallium-201 chloride pharmaceuticals production practice at the Medradiopreparat factory under USSR Ministry of Public Health is described. The factory is carried out series-produced supplies of the compound prepared according to a new practice from September, 1985. Thallium-201 extraction from cyclotron targets irradiated is carried out by the extraction method

  14. Use of prediction equations to determine the accuracy of whole-body fat and fat-free mass and appendicular skeletal muscle mass measurements from a single abdominal image using computed tomography in advanced cancer patients.

    Science.gov (United States)

    Kilgour, Robert D; Cardiff, Katrina; Rosenthall, Leonard; Lucar, Enriqueta; Trutschnigg, Barbara; Vigano, Antonio

    2016-01-01

    Measurements of body composition using dual-energy X-ray absorptiometry (DXA) and single abdominal images from computed tomography (CT) in advanced cancer patients (ACP) have important diagnostic and prognostic value. The question arises as to whether CT scans can serve as surrogates for DXA in terms of whole-body fat-free mass (FFM), whole-body fat mass (FM), and appendicular skeletal muscle (ASM) mass. Predictive equations to estimate body composition for ACP from CT images have been proposed (Mourtzakis et al. 2008; Appl. Physiol. Nutr. Metabol. 33(5): 997-1006); however, these equations have yet to be validated in an independent cohort of ACP. Thus, this study evaluated the accuracy of these equations in estimating FFM, FM, and ASM mass using CT images at the level of the third lumbar vertebrae and compared these values with DXA measurements. FFM, FM, and ASM mass were estimated from the prediction equations proposed by Mourtzakis and colleagues (2008) using single abdominal CT images from 43 ACP and were compared with whole-body DXA scans using Spearman correlations and Bland-Altman analyses. Despite a moderate to high correlation between the actual (DXA) and predicted (CT) values for FM (rho = 0.93; p ≤ 0.001), FFM (rho = 0.78; p ≤ 0.001), and ASM mass (rho = 0.70; p ≤ 0.001), Bland-Altman analyses revealed large range-of-agreement differences between the 2 methods (29.39 kg for FFM, 15.47 kg for FM, and 3.99 kg for ASM mass). Based on the magnitude of these differences, we concluded that prediction equations using single abdominal CT images have poor accuracy, cannot be considered as surrogates for DXA, and may have limited clinical utility.

  15. [Thallium poisoning which stimulated systemic lupus erythematosus in a child].

    Science.gov (United States)

    Montoya-Cabrera, M A; Sauceda-García, J M; Escalante-Galindo, P; López-Morales, E

    1991-01-01

    We report the case of a preschool boy who, without knowledge of his relatives, ingested thallium sulfate in a dose calculated in 30 mg/kg. He presented a systemic lupus erythematosus-like syndrome and only further alopecia oriented the diagnosis of thallium toxicosis; thallium blood levels were; 37.2 micrograms/dl and in urine: 2330 micrograms/L. Treatment with the chelating agent D. penicillamine was effective, the clinical picture disappeared and the decrease of the thallium levels was observed. Thallium intoxication should be considered in the differential diagnosis of connective tissue disease as the above mentioned.

  16. Evaluation of dual-source parallel RF excitation for diffusion-weighted whole-body MR imaging with background body signal suppression at 3.0 T

    Energy Technology Data Exchange (ETDEWEB)

    Muertz, Petra, E-mail: petra.muertz@ukb.uni-bonn.de [Department of Radiology, University of Bonn (Germany); Kaschner, Marius, E-mail: marius.kaschner@ukb.uni-bonn.de [Department of Radiology, University of Bonn (Germany); Traeber, Frank, E-mail: frank.traeber@ukb.uni-bonn.de [Department of Radiology, University of Bonn (Germany); Kukuk, Guido M., E-mail: guido.kukuk@ukb.uni-bonn.de [Department of Radiology, University of Bonn (Germany); Buedenbender, Sarah M., E-mail: sarah_m_buedenbender@yahoo.de [Department of Radiology, University of Bonn (Germany); Skowasch, Dirk, E-mail: dirk.skowasch@ukb.uni-bonn.de [Department of Medicine, University of Bonn (Germany); Gieseke, Juergen, E-mail: juergen.gieseke@philips.com [Philips Healthcare, Best (Netherlands); Department of Radiology, University of Bonn (Germany); Schild, Hans H., E-mail: hans.schild@ukb.uni-bonn.de [Department of Radiology, University of Bonn (Germany); Willinek, Winfried A., E-mail: winfried.willinek@ukb.uni-bonn.de [Department of Radiology, University of Bonn (Germany)

    2012-11-15

    Purpose: To evaluate the use of dual-source parallel RF excitation (TX) for diffusion-weighted whole-body MRI with background body signal suppression (DWIBS) at 3.0 T. Materials and methods: Forty consecutive patients were examined on a clinical 3.0-T MRI system using a diffusion-weighted (DW) spin-echo echo-planar imaging sequence with a combination of short TI inversion recovery and slice-selective gradient reversal fat suppression. DWIBS of the neck (n = 5), thorax (n = 8), abdomen (n = 6) and pelvis (n = 21) was performed both with TX (2:56 min) and with standard single-source RF excitation (4:37 min). The quality of DW images and reconstructed inverted maximum intensity projections was visually judged by two readers (blinded to acquisition technique). Signal homogeneity and fat suppression were scored as 'improved', 'equal', 'worse' or 'ambiguous'. Moreover, the apparent diffusion coefficient (ADC) values were measured in muscles, urinary bladder, lymph nodes and lesions. Results: By the use of TX, signal homogeneity was 'improved' in 25/40 and 'equal' in 15/40 cases. Fat suppression was 'improved' in 17/40 and 'equal' in 23/40 cases. These improvements were statistically significant (p < 0.001, Wilcoxon signed-rank test). In five patients, fluid-related dielectric shading was present, which improved remarkably. The ADC values did not significantly differ for the two RF excitation methods (p = 0.630 over all data, pairwise Student's t-test). Conclusion: Dual-source parallel RF excitation improved image quality of DWIBS at 3.0 T with respect to signal homogeneity and fat suppression, reduced scan time by approximately one-third, and did not influence the measured ADC values.

  17. Correction for patient and organ movement in SPECT: application to exercise thallium-201 cardiac imaging

    International Nuclear Information System (INIS)

    Geckle, W.J.; Frank, T.L.; Links, J.M.; Becker, L.C.

    1988-01-01

    We describe a technique for correction of artifacts in exercise 201 Tl single photon emission computed tomography (SPECT) images arising from abrupt or gradual translational movement of the heart during acquisition. The procedure involves the tracking of the center of the heart in serial projection images using an algorithm which we call diverging squares. Each projection image is then realigned in the x-y plane so that the heart center conforms to the projected position of a fixed point in space. The shifted projections are reconstructed using the normal filtered backprojection algorithm. In validation studies, the motion correction procedure successfully eliminated movement artifacts in a heart phantom. Image quality was also improved in over one-half of 36 exercise thallium patient studies. The corrected images had smoother and more continuous left ventricular walls, greater clarity of the left ventricular cavity, and reduced streak artifacts. Rest injected or redistribution images, however, were often made worse, due to reduced heart to liver activity ratios and poor tracking of the heart center. Analysis of curves of heart position versus projection angle suggests that translation of the heart is common during imaging after exercise, and results from both abrupt patient movements, and a gradual upward shift of the heart. Our motion correction technique appears to represent a promising new approach for elimination of movement artifacts and enhancement of resolution in exercise 201 Tl cardiac SPECT images

  18. Nanosized f.c.c. thallium inclusions in aluminium

    International Nuclear Information System (INIS)

    Johnson, E.; Johansen, A.; Thoft, N.B.; Andersen, H.H.; Sarholt-Kristensen, L.

    1993-01-01

    Ion implantation of pure aluminium with thallium induces the formation of nanosized crystalline inclusions of thallium with a f.c.c. structure. The size of the inclusions depends on the implantation conditions and subsequent annealing treatments and is typically in the range from 1 to 10 nm. The inclusions are aligned topotactically with the aluminium matrix with a cube-cube orientation relationship and they have a truncated octahedral shape bounded by {111} and {001} planes. The lattice parameter of the f.c.c. thallium inclusions is 0.484 ± 0.002 nm, which is slightly but significantly larger than in the high-pressure f.c.c. thallium phase known to be stable above 3.8 GPa. (Author)

  19. A method for the production of thallium-201

    International Nuclear Information System (INIS)

    Ageev, V.A.; Kljuchnikov, A.A.; Linev, A.F.; Khalkin, V.A.; Zaitseva, N.G.

    1987-01-01

    For the production of thallium-201 a target of at least 95% enriched pure lead-206 is irradiated by a proton beam of an energy of between 50 and 70 MeV. During irradiation the reaction 206 Pb(p,6n) 201 Bi takes place. The target is kept sufficiently long for the transition 201 Bi- 201 Pb- 201 Tl to take place. The target is then dissolved in acid. The thallium-201 contained in the acid is oxidized to the trivalent state followed by precipitation of the lead. Lead traces remaining in solution are separated from the thallium-201 through cation exchange following which the thallium-201 is eluted using hydrochloric acid

  20. Whole-Body MRI Virtual Autopsy Using Diffusion-weighted Imaging With Background Suppression (DWIBS) at 3 T in a Child Succumbing to Chordoma.

    Science.gov (United States)

    Andronikou, Savvas; Kemp, Marnie L; Meiring, Michelle

    2017-03-01

    We report the use of diffusion-weighted imaging with background suppression (DWIBS) in pediatric virtual magnetic resonance imaging (MRI) autopsy of a child who succumbed to chordoma. A 10-year-old girl who succumbed to relapse of a chordoma underwent whole-body virtual MRI autopsy 12 hours postmortem with short Tau inversion recovery (STIR) and DWIBS on 3 T, which demonstrated the primary mass, local and cardiac invasion, and metastatic disease to the thorax, abdomen, head/neck, and musculoskeletal system. Postmortem virtual MRI autopsy including DWIBS successfully demonstrated the transthoracic spread of chordoma and invasion of the heart, resulting in blood-borne metastases. Motion and respiratory artifact were not factors during virtual autopsy using DWIBS on 3 T, making ideal use of this technology.

  1. The whole-body counter of the radiation centre Giessen

    International Nuclear Information System (INIS)

    Strobelt, W.

    1976-01-01

    The layout of the whole-body counter at the institute for biophysics of the Giessen radiation centre is decribed. With suitable collimators, the whole-body counter may be used to determine the radioactivity in human and animal organs. The shielding and the measuring and waiting rooms for the patients are described with regard to their technical details. The whole-body counting system enables the radioactivity and the retention of various radioisotopes (e.g. 58 Co-vitamin B 12 , 40 K, 54 Mn, 137 Co, 131 J, 22 Na) to be measured. The estimation of the radiation exposure due to different types of examinations in nuclear medicine, in terms of the critical organs for each type of examination, is very accurate with this counting device. (GSE) [de

  2. Assessing the body image: relevance, application and instruments for oncological settings.

    Science.gov (United States)

    Annunziata, Maria Antonietta; Giovannini, Lorena; Muzzatti, Barbara

    2012-05-01

    Body image is the sum of physical, cognitive, emotional, and relational elements that, when integrated, allow the development of a whole, healthy self-identity. Even though body image is normally studied in relation to eating disorders, it can also be influenced by other pathologies, including cancer. In oncology, an effective body image assessment is fundamental. The physical effects of cancer and cancer treatments are important and frequently irreversible also on a functional and emotional level; however, only few surveys have investigated body image in this peculiar context. An extensive literature review was carried out in PubMed and PsycINFO. We considered articles published from 1990 to 2010. Two hundred sixty-three papers matched the search criteria. Assessment methodologies included clinical interviews, self-report measures, questionnaires, symptom check lists, and graphic tests and projective techniques. After excluding the instruments that referred to eating disorders, validated only for adolescents, and/or projective and graphic tests, we found 81 articles with six questionnaires specifically dedicated to body image assessment in oncology. From our systematic review, we could identify six instruments specifically designed for assessing body image in the oncological area. In this paper, we discuss their general characteristics, psychometrics properties and the clinical implications, and body image relevance on the quality of life in cancer patients.

  3. Isoproterenol stress thallium scintigraphy for detecting coronary artery disease

    International Nuclear Information System (INIS)

    Watanabe, Shigeyuki; Ajisaka, Ryuichi; Masuoka, Takeshi; Iida, Kaname; Sugishita, Yasuro; Ito, Iwao; Takeda, Tohru; Toyama, Hinako; Akisada, Masayoshi

    1989-01-01

    The present study was undertaken to assess the diagnostic value of isoproterenol (ISP) thallium scintigraphy. The findings were compared with those of ISP-ECG and exercise thallium scintigraphy. The study population consisted of 24 patients who had a history of chest pain without previous myocardial infarction. ISP was given at increasing doses of 0.02, 0.04, 0.08 μg/mg/min at 3-minutes intervals, and was terminated for any of the following reasons: angina, significant arrhythmia, significant ST segment depression, or target heart rate. Thallium scintigrams were obtained immediately after terminating ISP infusion, and after a 3-hour delay, redistribution scans were obtained. Scintigrams were considered positive when a reversible defect was present. After stress tests, coronary angiography was performed. According to the presence or absence of significant coronary artery stenosis, the patients were divided into coronary artery disease (CAD) group (n=12) and so-called normal coronary (NC) group (n=12). Among 12 patients in the CAD group, ISP induced anginal pain in six (50%), and ISP-ECT and ISP thallium scintigraphy were positive in 10 (83%) and in 11 (92%), compared with four(33%), four(33%) and two (17%) in the NC group. These data indicate that ISP-ECG had a sensitivity of 83%, a specificity of 67%, and a diagnostic accuracy of 75%; and the corresponding figures for ISP thallium scintigraphy were 92%, 83%, and 88%. Among nine patients who underwent both ISP thallium scintgraphy and exercise thallium scintigraphy, all patients, except for one false negative case on ISP thallium scintigraphy, were correctly diagnosed. No serious complications occurred in association with the ISP infusion test. ISP thallium scintigraphy was considered to be a safe, sensitive, and specific method for diagnosing CAD when exercise tests were intolerable. (N.K.)

  4. Psoas muscle cross-sectional area as a measure of whole body lean muscle mass in maintenance hemodialysis patients

    Science.gov (United States)

    Morrell, Glen R.; Ikizler, Talat A.; Chen, Xiaorui; Heilbrun, Marta E.; Wei, Guo; Boucher, Robert; Beddhu, Srinivasan

    2016-01-01

    Objective We investigate whether psoas or paraspinous muscle area measured on a single L4–5 image is a useful measure of whole lean body mass compared to dedicated mid-thigh magnetic resonance imaging (MRI). Design Observational study. Setting Outpatient dialysis units and a research clinic. Subjects 105 adult participants on maintenance hemodialysis. No control group was used. Exposure variables Psoas muscle area, paraspinous muscle area, and mid-thigh muscle area (MTMA) were measured by MRI. Main outcome measure Lean body mass was measured by dual-energy absorptiometry (DEXA) scan. Results In separate multivariable linear regression models, psoas, paraspinous, and mid-thigh muscle area were associated with increase in lean body mass. In separate multivariate logistic regression models, c-statistics for diagnosis of sarcopenia (defined as lean body mass) were 0.69 for paraspinous muscle area, 0.81 for psoas muscle area, and 0.89 for mid-thigh muscle area. With sarcopenia defined as lean body mass, the corresponding c-statistics were 0.71, 0.92, and 0.94. Conclusions We conclude that psoas muscle area provides a good measure of whole body muscle mass, better than paraspinous muscle area but slightly inferior to mid thigh measurement. Hence, in body composition studies a single axial MR image at the L4–L5 level can be used to provide information on both fat and muscle and may eliminate the need for time-consuming measurement of muscle area in the thigh. PMID:26994780

  5. Optimization of a shorter variable-acquisition time for legs to achieve true whole-body PET/CT images.

    Science.gov (United States)

    Umeda, Takuro; Miwa, Kenta; Murata, Taisuke; Miyaji, Noriaki; Wagatsuma, Kei; Motegi, Kazuki; Terauchi, Takashi; Koizumi, Mitsuru

    2017-12-01

    The present study aimed to qualitatively and quantitatively evaluate PET images as a function of acquisition time for various leg sizes, and to optimize a shorter variable-acquisition time protocol for legs to achieve better qualitative and quantitative accuracy of true whole-body PET/CT images. The diameters of legs to be modeled as phantoms were defined based on data derived from 53 patients. This study analyzed PET images of a NEMA phantom and three plastic bottle phantoms (diameter, 5.68, 8.54 and 10.7 cm) that simulated the human body and legs, respectively. The phantoms comprised two spheres (diameters, 10 and 17 mm) containing fluorine-18 fluorodeoxyglucose solution with sphere-to-background ratios of 4 at a background radioactivity level of 2.65 kBq/mL. All PET data were reconstructed with acquisition times ranging from 10 to 180, and 1200 s. We visually evaluated image quality and determined the coefficient of variance (CV) of the background, contrast and the quantitative %error of the hot spheres, and then determined two shorter variable-acquisition protocols for legs. Lesion detectability and quantitative accuracy determined based on maximum standardized uptake values (SUV max ) in PET images of a patient using the proposed protocols were also evaluated. A larger phantom and a shorter acquisition time resulted in increased background noise on images and decreased the contrast in hot spheres. A visual score of ≥ 1.5 was obtained when the acquisition time was ≥ 30 s for three leg phantoms, and ≥ 120 s for the NEMA phantom. The quantitative %errors of the 10- and 17-mm spheres in the leg phantoms were ± 15 and ± 10%, respectively, in PET images with a high CV (scan mean SUV max of three lesions using the current fixed-acquisition and two proposed variable-acquisition time protocols in the clinical study were 3.1, 3.1 and 3.2, respectively, which did not significantly differ. Leg acquisition time per bed position of even 30-90

  6. Anhydrous thallium hydrogen L-glutamate: polymer networks formed by sandwich layers of oxygen-coordinated thallium ions cores shielded by hydrogen L-glutamate counterions.

    Science.gov (United States)

    Bodner, Thomas; Wirnsberger, Bianca; Albering, Jörg; Wiesbrock, Frank

    2011-11-07

    Anhydrous thallium hydrogen L-glutamate [Tl(L-GluH)] crystallizes from water (space group P2(1)) with a layer structure in which the thallium ions are penta- and hexacoordinated exclusively by the oxygen atoms of the γ-carboxylate group of the hydrogen L-glutamate anions to form a two-dimensional coordination polymer. The thallium-oxygen layer is composed of Tl(2)O(2) and TlCO(2) quadrangles and is only 3 Å high. Only one hemisphere of the thallium ions participates in coordination, indicative of the presence of the 6s(2) lone pair of electrons. The thallium-oxygen assemblies are shielded by the hydrogen l-glutamate anions. Only the carbon atom of the α-carboxylate group deviates from the plane spanned by the thallium ions, the γ-carboxylate groups and the proton bearing carbon atoms, which are in trans conformation. Given the abundance of L-glutamic and L-aspartic acid in biological systems on the one hand and the high toxicity of thallium on the other hand, it is worth mentioning that the dominant structural motifs in the crystal structure of [Tl(L-GluH)] strongly resemble their corresponding analogues in the crystalline phase of [K(L-AspH)(H(2)O)(2)].

  7. [Perspectives on body: embodiment and body image].

    Science.gov (United States)

    Chang, Shiow-Ru; Chao, Yu-Mei Yu

    2007-06-01

    "Body" is a basic concept of both the natural and human sciences. This extensive review of the literature explores the various philosophical approaches to the body, including empiricism, idealism, existentialism and phenomenology, as well as the relationship between body and mind. Embodiment and body image are the two main concepts of body addressed in this article. Merleau-Ponty's perspective on embodiment, an important new area of theory development, emphasizes that embodiment research must focus on life experiences, such as the study of body image. Using Schilder's framework of psychosocialology, this article provides a comprehensive understanding of the concept of body image and women's perspectives on the "body" in both Western culture and Eastern cultures. Body size and shape significantly influence the self-image of women. Body image is something that develops and changes throughout one's life span and is continually being constructed, destructed, and reconstructed. Personal body image has important psychological effects on the individual, especially women. This integrative review can make a significant contribution to knowledge in this area and, consequently, to related practice and research.

  8. Scintigraphic visualization of myocardial infarcts in baboons using thallium-201 and technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Frick, M P; Ponto, R A; Pyle, R B; Yasmineh, W G; Loken, M K

    1978-01-01

    Four baboons with myocardial infarcts were evaluated using thallium-201 for myocardial imaging and /sup 99m/Tc pyrophosphate for infarct visualization. Scintiphotographic findings were compared with the size of myocardial infarcts calculated from measurements of the activity of MB isoenzymes of creatine kinase (CK-MB) in serum and in the myocardium at autopsy, as described by Sobel's method. Lack of thallium-201 accumulation was noted in left ventricular infarcts of 3 of the 4 baboons. These same areas localized /sup 99m/Tc pyrophosphate administered 24 to 30 h after infarction.

  9. Dry coupling for whole-body small-animal photoacoustic computed tomography

    Science.gov (United States)

    Yeh, Chenghung; Li, Lei; Zhu, Liren; Xia, Jun; Li, Chiye; Chen, Wanyi; Garcia-Uribe, Alejandro; Maslov, Konstantin I.; Wang, Lihong V.

    2017-04-01

    We have enhanced photoacoustic computed tomography with dry acoustic coupling that eliminates water immersion anxiety and wrinkling of the animal and facilitates incorporating complementary modalities and procedures. The dry acoustic coupler is made of a tubular elastic membrane enclosed by a closed transparent water tank. The tubular membrane ensures water-free contact with the animal, and the closed water tank allows pressurization for animal stabilization. The dry coupler was tested using a whole-body small-animal ring-shaped photoacoustic computed tomography system. Dry coupling was found to provide image quality comparable to that of conventional water coupling.

  10. Whole-body-MR imaging including DWIBS in the work-up of patients with head and neck squamous cell carcinoma: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Noij, Daniel P., E-mail: d.noij@vumc.nl [Department of Radiology and Nuclear Medicine, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam (Netherlands); Boerhout, Els J., E-mail: e.boerhout@vumc.nl [Department of Radiology and Nuclear Medicine, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam (Netherlands); Pieters-van den Bos, Indra C., E-mail: i.pieters@vumc.nl [Department of Radiology and Nuclear Medicine, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam (Netherlands); Comans, Emile F., E-mail: efi.comans@vumc.nl [Department of Radiology and Nuclear Medicine, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam (Netherlands); Oprea-Lager, Daniela, E-mail: d.oprea-lager@vumc.nl [Department of Radiology and Nuclear Medicine, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam (Netherlands); Reinhard, Rinze, E-mail: r.reinhard@vumc.nl [Department of Radiology and Nuclear Medicine, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam (Netherlands); Hoekstra, Otto S., E-mail: os.hoekstra@vumc.nl [Department of Radiology and Nuclear Medicine, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam (Netherlands); Bree, Remco de, E-mail: r.debree@vumc.nl [Department Otolaryngology/Head and Neck Surgery, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam (Netherlands); Graaf, Pim de, E-mail: p.degraaf@vumc.nl [Department of Radiology and Nuclear Medicine, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam (Netherlands); Castelijns, Jonas A., E-mail: j.castelijns@vumc.nl [Department of Radiology and Nuclear Medicine, VU University Medical Center, De Boelelaan 1117, PO Box 7057, 1007 MB Amsterdam (Netherlands)

    2014-07-15

    Objectives: To assess the feasibility of whole-body magnetic resonance imaging (WB-MRI) including diffusion-weighted whole-body imaging with background-body-signal-suppression (DWIBS) for the evaluation of distant malignancies in head and neck squamous cell carcinoma (HNSCC); and to compare WB-MRI findings with {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG-PET/CT) and chest-CT. Methods: Thirty-three patients with high risk for metastatic spread (26 males; range 48–79 years, mean age 63 ± 7.9 years (mean ± standard deviation) years) were prospectively included with a follow-up of six months. WB-MRI protocol included short-TI inversion recovery and T1-weighted sequences in the coronal plane and half-fourier acquisition single-shot turbo spin-echo T2 and contrast-enhanced-T1-weighted sequences in the axial plane. Axial DWIBS was reformatted in the coronal plane. Interobserver variability was assessed using weighted kappa and the proportion specific agreement (PA). Results: Two second primary tumors and one metastasis were detected on WB-MRI. WB-MRI yielded seven clinically indeterminate lesions which did not progress at follow-up. The metastasis and one second primary tumor were found when combining {sup 18}F-FDG-PET/CT and chest-CT findings. Interobserver variability for WB-MRI was κ = 0.91 with PA ranging from 0.82 to 1.00. For {sup 18}F-FDG-PET/CT κ could not be calculated due to a constant variable in the table and PA ranged from 0.40 to 0.99. Conclusions: Our WB-MRI protocol with DWIBS is feasible in the work-up of HNSCC patients for detection and characterization of distant pathology. WB-MRI can be complementary to {sup 18}F-FDG-PET/CT, especially in the detection of non {sup 18}F-FDG avid second primary tumors.

  11. Detection of metastatic thyroid carcinoma through whole body counting

    International Nuclear Information System (INIS)

    Novenario, H.S.; Pascacio, F.M.; Cruz, Benjamin de la; Anden, A.B.

    Whole body counters are not only used in measuring radioactivity in the body for radiation protection purposes but also in the measurement of iron absorption, body potassium and cesium, chronic blood loss, and also in the determination of the effectiveness of surgery, thyroid hormone and radioactive iodine therapy in thyroid carcinoma. This report deals with our experience in the use of a shadow-shield whole body counter in the determination of I-131 uptake by metastatic lesions of cancer of thyroid after total thyroidectomy and ablation therapy with I-131. This study was undertaken jointly by the Department of Nuclear Medicine, Veterans Memorial Hospital and the Biomedical Research Division of the Philippine Atomic Energy Commission. Preliminary results indicate that the 22 patients who underwent whole body counting after total thyroidectomy I-131 ablation therapy, 9 patients had elevated percentage retention of I-131, 10 patients with normal values and 3 patients with rising values. Foci of I-131 concentration in those with elevated and rising percentage concentration values were seen in the thyroidal bed scintiscans, while the 10 patients with normal values had negative scintiscans. The results of our observations confirm the results obtained by other workers abroad. Our preliminary results indicate that with the use of whole body counters a sensitive method of assessing whether functioning metastatic lesion of cancer of the thyroid still exist after total thyroidectomy and I-131 ablation therapy can be provided. (author)

  12. Vibration and Noise in Magnetic Resonance Imaging of the Vocal Tract: Differences between Whole-Body and Open-Air Devices.

    Science.gov (United States)

    Přibil, Jiří; Přibilová, Anna; Frollo, Ivan

    2018-04-05

    This article compares open-air and whole-body magnetic resonance imaging (MRI) equipment working with a weak magnetic field as regards the methods of its generation, spectral properties of mechanical vibration and acoustic noise produced by gradient coils during the scanning process, and the measured noise intensity. These devices are used for non-invasive MRI reconstruction of the human vocal tract during phonation with simultaneous speech recording. In this case, the vibration and noise have negative influence on quality of speech signal. Two basic measurement experiments were performed within the paper: mapping sound pressure levels in the MRI device vicinity and picking up vibration and noise signals in the MRI scanning area. Spectral characteristics of these signals are then analyzed statistically and compared visually and numerically.

  13. Automated Whole-Body Bone Lesion Detection for Multiple Myeloma on 68Ga-Pentixafor PET/CT Imaging Using Deep Learning Methods.

    Science.gov (United States)

    Xu, Lina; Tetteh, Giles; Lipkova, Jana; Zhao, Yu; Li, Hongwei; Christ, Patrick; Piraud, Marie; Buck, Andreas; Shi, Kuangyu; Menze, Bjoern H

    2018-01-01

    The identification of bone lesions is crucial in the diagnostic assessment of multiple myeloma (MM). 68 Ga-Pentixafor PET/CT can capture the abnormal molecular expression of CXCR-4 in addition to anatomical changes. However, whole-body detection of dozens of lesions on hybrid imaging is tedious and error prone. It is even more difficult to identify lesions with a large heterogeneity. This study employed deep learning methods to automatically combine characteristics of PET and CT for whole-body MM bone lesion detection in a 3D manner. Two convolutional neural networks (CNNs), V-Net and W-Net, were adopted to segment and detect the lesions. The feasibility of deep learning for lesion detection on 68 Ga-Pentixafor PET/CT was first verified on digital phantoms generated using realistic PET simulation methods. Then the proposed methods were evaluated on real 68 Ga-Pentixafor PET/CT scans of MM patients. The preliminary results showed that deep learning method can leverage multimodal information for spatial feature representation, and W-Net obtained the best result for segmentation and lesion detection. It also outperformed traditional machine learning methods such as random forest classifier (RF), k -Nearest Neighbors ( k -NN), and support vector machine (SVM). The proof-of-concept study encourages further development of deep learning approach for MM lesion detection in population study.

  14. Automated Whole-Body Bone Lesion Detection for Multiple Myeloma on 68Ga-Pentixafor PET/CT Imaging Using Deep Learning Methods

    Directory of Open Access Journals (Sweden)

    Lina Xu

    2018-01-01

    Full Text Available The identification of bone lesions is crucial in the diagnostic assessment of multiple myeloma (MM. 68Ga-Pentixafor PET/CT can capture the abnormal molecular expression of CXCR-4 in addition to anatomical changes. However, whole-body detection of dozens of lesions on hybrid imaging is tedious and error prone. It is even more difficult to identify lesions with a large heterogeneity. This study employed deep learning methods to automatically combine characteristics of PET and CT for whole-body MM bone lesion detection in a 3D manner. Two convolutional neural networks (CNNs, V-Net and W-Net, were adopted to segment and detect the lesions. The feasibility of deep learning for lesion detection on 68Ga-Pentixafor PET/CT was first verified on digital phantoms generated using realistic PET simulation methods. Then the proposed methods were evaluated on real 68Ga-Pentixafor PET/CT scans of MM patients. The preliminary results showed that deep learning method can leverage multimodal information for spatial feature representation, and W-Net obtained the best result for segmentation and lesion detection. It also outperformed traditional machine learning methods such as random forest classifier (RF, k-Nearest Neighbors (k-NN, and support vector machine (SVM. The proof-of-concept study encourages further development of deep learning approach for MM lesion detection in population study.

  15. Design and evaluation of HEADTOME-IV, a whole-body positron emission tomograph

    International Nuclear Information System (INIS)

    Iida, H.; Miura, S.; Kanno, I.; Murakami, M.; Takahashi, K.; Uemura, K.

    1989-01-01

    A whole body positron emission tomograph HEADTOME-IV has been developed, and its physical performances were investigated. The in-plane spatial resolution of 4.5 mm was realized with stationary-sampling at the center of the field-of-view. The axial slice thickness was 9.5 and 9.0-mm for direct and cross planes, respectively. By moving the gantry framework axially, transaxial images of 14 or 21 slices are obtained quasi-simultaneously. The realtime-operation large-scale cache memory system was effective to realize realtime corrections for deadtime and radionuclide decay, and realtime weighted integration for the purpose of a rapid calculation of rate-constant images

  16. Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner

    International Nuclear Information System (INIS)

    Visvikis, D.; Griffiths, D.; Costa, D.C.; Bomanji, J.; Ell, P.J.

    2005-01-01

    Three-dimensional positron emission tomography (3D PET) results in higher system sensitivity, with an associated increase in the detection of scatter and random coincidences. The objective of this work was to compare, from a clinical perspective, 3D and two-dimensional (2D) acquisitions in terms of whole-body (WB) PET image quality with a dedicated BGO PET system. 2D and 3D WB emission acquisitions were carried out in 70 patients. Variable acquisition parameters in terms of time of emission acquisition per axial field of view (aFOV) and slice overlap between sequential aFOVs were used during the 3D acquisitions. 3D and 2D images were reconstructed using FORE+WLS and OSEM respectively. Scatter correction was performed by convolution subtraction and a model-based scatter correction in 2D and 3D respectively. All WB images were attenuation corrected using segmented transmission scans. Images were blindly assessed by three observers for the presence of artefacts, confidence in lesion detection and overall image quality using a scoring system. Statistically significant differences between 2D and 3D image quality were only obtained for 3D emission acquisitions of 3 min. No statistically significant differences were observed for image artefacts or lesion detectability scores. Image quality correlated significantly with patient weight for both modes of operation. Finally, no differences were seen in image artefact scores for the different axial slice overlaps considered, suggesting the use of five slice overlaps in 3D WB acquisitions. 3D WB imaging using a dedicated BGO-based PET scanner offers similar image quality to that obtained in 2D considering similar overall times of acquisitions. (orig.)

  17. Thallium in the solar atmosphere.

    Science.gov (United States)

    Lambert, D. L.; Mallia, E. A.; Smith, G.

    1972-01-01

    Evidence for the presence of thallium in the sun is presented. Umbral spectra were found to contain an absorption feature at or near the predicted position for the Tl I 5350 A line. Analysis of the 5350 A line indicated that the solar thallium abundance is given by log N(Tl) values ranging from 0.72 to 1.07 on the standard scale log N(H) = 12.00. Unidentified blends, however, limit the accuracy of the abundance determination.

  18. Implicit Beliefs about Ideal Body Image Predict Body Image Dissatisfaction

    Directory of Open Access Journals (Sweden)

    Niclas eHeider

    2015-10-01

    Full Text Available We examined whether implicit measures of actual and ideal body image can be used to predict body dissatisfaction in young female adults. Participants completed two Implicit Relational Assessment Procedures (IRAPs to examine their implicit beliefs concerning actual (e.g., I am thin and desired ideal body image (e.g., I want to be thin. Body dissatisfaction was examined via self-report questionnaires and rating scales. As expected, differences in body dissatisfaction exerted a differential influence on the two IRAP scores. Specifically, the implicit belief that one is thin was lower in participants who exhibited a high degree of body dissatisfaction than in participants who exhibited a low degree of body dissatisfaction. In contrast, the implicit desire to be thin (i.e., thin ideal body image was stronger in participants who exhibited a high level of body dissatisfaction than in participants who were less dissatisfied with their body. Adding further weight to the idea that both IRAP measures captured different underlying constructs, we also observed that they correlated differently with body mass index, explicit body dissatisfaction, and explicit measures of actual and ideal body image. More generally, these findings underscore the advantage of using implicit measures that incorporate relational information relative to implicit measures that allow for an assessment of associative relations only.

  19. Comparison of urinary thallium levels in non-occupationally exposed people and workers.

    Science.gov (United States)

    Staff, James F; Cotton, Richard J; Warren, Nicholas D; Morton, Jackie

    2014-04-01

    To determine a reference background urinary thallium level; to compare urinary thallium data from workers to this background level; to investigate factors affecting these levels and whether creatinine correction is appropriate. Urine samples from non-occupationally exposed people (n = 273, from 113 individuals) and workers (n = 896, from 447 individuals) were analysed for thallium by ICP-MS. A reference background level was calculated, defined as the 95th percentile value of a non-occupationally exposed population. Worker data were divided into two subsets: thallium workers (those who work directly with thallium or its compounds) and general workers; and compared to the background level. Bayesian linear mixed effects modelling was used to investigate factors affecting urinary thallium concentration and the efficacy of creatinine correction for the determination of urinary thallium. The reference background urinary thallium level is 0.27 μmol/mol creatinine (creatinine-corrected) or 0.40 μg/l (uncorrected). Median values were 0.11 μmol/mol creatinine or 0.17 μg/l for non-occupationally exposed people, 0.12 μmol/mol creatinine or 0.20 μg/l for general workers and 0.19 μmol/mol creatinine or 0.41 μg/l for thallium workers. Variation was lower in creatinine-corrected models. Nine per cent of samples from general workers and 39 % of samples from thallium workers exceeded the creatinine-corrected background level. By 2010, 90 % of all workers had urinary thallium levels below the 95th percentile reference background level. Urinary thallium concentrations were higher in thallium workers than non-occupationally exposed people and general workers. Creatinine correction is appropriate.

  20. Whole-body ring-shaped confocal photoacoustic computed tomography of small animals in vivo

    Science.gov (United States)

    Xia, Jun; Chatni, Muhammad R.; Maslov, Konstantin; Guo, Zijian; Wang, Kun; Anastasio, Mark; Wang, Lihong V.

    2012-05-01

    We report a novel small-animal whole-body imaging system called ring-shaped confocal photoacoustic computed tomography (RC-PACT). RC-PACT is based on a confocal design of free-space ring-shaped light illumination and 512-element full-ring ultrasonic array signal detection. The free-space light illumination maximizes the light delivery efficiency, and the full-ring signal detection ensures a full two-dimensional view aperture for accurate image reconstruction. Using cylindrically focused array elements, RC-PACT can image a thin cross section with 0.10 to 0.25 mm in-plane resolutions and 1.6 s/frame acquisition time. By translating the mouse along the elevational direction, RC-PACT provides a series of cross-sectional images of the brain, liver, kidneys, and bladder.

  1. Detection of Recurrent Cervical Cancer by Whole-body FDG PET Scans

    Institute of Scientific and Technical Information of China (English)

    Jiaxin Yang; Jinhui Wang; Zhaohui Zhu; Keng Shen; Bocheng Wang

    2008-01-01

    OBJECTIVE To evaluate the role of whole-body {18F} fluro-2-dexoxyglucose (FDG) positron emission tomography (PET) scans in the detection of recurrent cervical cancer.METHODS Between June, 2000 and January, 2006, 25 patients had undergone a PET scan at the Peking Union Medical College Hospital to evaluate possible recurrent cervical cancer. All the PET findings were reviewed and compared to available clinical data to classify each PET scan result as a true positive, true negative, false positive, or false negative.RESULTS A total of 38 PET scans were conducted on the 25patients whose median age was 46 years. The Stage distributions were IA (n = 1), IB (n = 11), IIA (n = 5), IIB (n = 4), IIIB (n = 2), WB (n= 1), and unknown Stage (n = 1). There were 22 cases of squamous cell carcinoma and 3 cases of adenocarcinoma resulting in 9 true positive PET scans, 27 true negatives, 2 false positives and no false negatives. The sensitivity of the FDG PET scans for detecting recurrent cervical cancer was 100%, specificity 93.1%, positive predictive value 81.8%, and negative predictive value 100%.CONCLUSION The whole body FDG PET scans are a sensitive and specific imaging modality for the detection of recurrent cervical cancer. However the cost of PET scans is too high at this time. A large prospective study will determine whether this modality should be used routinely and take the place of other imaging methods in the early detection of recurrent cervical carcinoma

  2. Low-Dose Adefovir-Induced Hypophosphatemic Osteomalacia on Whole-Body Bone Scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hoon; Won, Kyoung Sook; Song, Bongil; Jo, Il; Zeon, Seok Kil [Keimyung Univ., Daegu (Korea, Republic of)

    2013-12-15

    While adefovir dipivoxil (ADV) effectively suppresses the hepatitis B virus, it can cause proximal renal tubular dysfunction leading to phosphate wasting. The safety of low-dose ADV (a dose of 10 mg/day), which does not induce clinically significant nephrotoxicity, is well recognized, but a few cases of hypophosphatemic osteomalacia (HO) caused by low-dose ADV therapy have recently been reported. Although HO induced by low-dose ADV therapy is rare, the presence of bone pain in patients treated with ADV should be monitored. Bone scintigraphy can be performed to confirm the occurrence of osteomalacia and to determine the disease extent. Bone scintigraphic and radiological image findings with a brief review of the literature are presented in this article. We report two cases of HO induced by low-dose ADV therapy that showed multifocal increased radiotracer uptakes in the bilateral bony ribs, spines, pelvic bones and lower extremities on whole-body bone scintigraphy. Bone pain gradually improved after phosphate supplementation and by changing the antiviral agent. Whole-body bone scintigraphy is a highly sensitive imaging tool and can show disease extent at once in the setting of the wide range of the clinical spectrum with nonspecific radiological findings. Furthermore, frequent involvement of the lower extremities, as a result of maximum weight bearing, could be an additional scintigraphic clue for the diagnosis of HO. These cases could be helpful for both clinicians prescribing ADV and nuclear physicians to prevent delayed diagnosis and plan further appropriate treatment.

  3. Low-Dose Adefovir-Induced Hypophosphatemic Osteomalacia on Whole-Body Bone Scintigraphy

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Won, Kyoung Sook; Song, Bongil; Jo, Il; Zeon, Seok Kil

    2013-01-01

    While adefovir dipivoxil (ADV) effectively suppresses the hepatitis B virus, it can cause proximal renal tubular dysfunction leading to phosphate wasting. The safety of low-dose ADV (a dose of 10 mg/day), which does not induce clinically significant nephrotoxicity, is well recognized, but a few cases of hypophosphatemic osteomalacia (HO) caused by low-dose ADV therapy have recently been reported. Although HO induced by low-dose ADV therapy is rare, the presence of bone pain in patients treated with ADV should be monitored. Bone scintigraphy can be performed to confirm the occurrence of osteomalacia and to determine the disease extent. Bone scintigraphic and radiological image findings with a brief review of the literature are presented in this article. We report two cases of HO induced by low-dose ADV therapy that showed multifocal increased radiotracer uptakes in the bilateral bony ribs, spines, pelvic bones and lower extremities on whole-body bone scintigraphy. Bone pain gradually improved after phosphate supplementation and by changing the antiviral agent. Whole-body bone scintigraphy is a highly sensitive imaging tool and can show disease extent at once in the setting of the wide range of the clinical spectrum with nonspecific radiological findings. Furthermore, frequent involvement of the lower extremities, as a result of maximum weight bearing, could be an additional scintigraphic clue for the diagnosis of HO. These cases could be helpful for both clinicians prescribing ADV and nuclear physicians to prevent delayed diagnosis and plan further appropriate treatment

  4. [Effect of body image in adolescent orthodontic treatment].

    Science.gov (United States)

    Minghui, Peng; Jing, Kang; Xiao, Deng

    2017-10-01

    This study was designed to probe the psychological factors adolescent orthodontic patients, the role of body image and self-esteem in the whole process of orthodontic treatment and the impact on the efficacy and satisfaction of orthodontic. Five hundred and twenty-eight patients were selected in this study. The Aesthetic Component of the Index of Orthodontic Treatment Need (IOTN-AC) , Rosenberg Self-Esteem Scale (SES), Negative Physical Self-General (NPS-G) and other body analysis scale study after orthodontic lasted 18-24 months were used to investigate the role of body image in adolescent orthodontic treatment. Esthetic evaluation of patients teeth after correction had been significantly improved, patient self-evaluation difference IOTN-AC doctor evaluation, Psychosocial Impact of Dental Aesthetics Questionnaire-tooth confidence, aesthetic concerns, psychological impact and social function were significantly improved. The improvement of the dental aesthetics component (T2 when doctors evaluate IOTN-AC) was positively correlated with the evaluation of the efficacy, and was significantly negatively correlated with the negative emotions of patients at baseline. Negative body image-dental dissatisfied-cognitive component and the affective component, the overall negative body image and negative emotions can predict patient satisfaction with treatment efficacy. Orthodontic treatment not only improves the self-aesthetic evaluation of adolescent patients, but also has a positive effect on the mental health of adolescent patients.

  5. Thallium-201 scintigraphy in unstable angina pectoris

    International Nuclear Information System (INIS)

    Wackers, F.J.T.; Lie, K.I.; Liem, K.L.; Sokole, E.B.; Samson, G.; Van Der Schoot, J.B.; Durrer, D.

    1978-01-01

    Thallium-201 scintigraphy was performed during the pain free period in 98 patients with unstable angina. Scintiscans were positive in 39 patients, questionable in 27 patients and normal in 32 patients. Eighty-one patients responded favorably to treatment (group I). Seventeen patients had complicated courses (group II) and despite maximal treatment with propranolol either developed infarction (six patients) or continued to have angina necessitating coronary surgery (11 patients). In group I during the pain free period 26 of 81 patients had positive thallium-201 scans, whereas 20 patients had an abnormal ECG at that time; during angina 18 patients had transient ECG changes. In group II during the pain free period 13 of 17 patients had positive scans, whereas two patients had abnormal ECG at that time; during angina 12 patients showed transient ECG changes. The sensitivity to recognize group II was 76% for thallium-201 scintigraphy, 11% for ECG during the pain free period; 70% for ECG during angina; 94% for the combination of either positive scans or abnormal ECG. Thus, positive thallium-201 scans occur in patients with unstable angina, positive scans can be obtained during the pain free period, thallium-201 scans are more frequently positive in patients with complicated course

  6. Three-dimensional optoacoustic tomography using a conventional ultrasound linear detector array: whole-body tomographic system for small animals.

    Science.gov (United States)

    Gateau, Jerome; Caballero, Miguel Angel Araque; Dima, Alexander; Ntziachristos, Vasilis

    2013-01-01

    Optoacoustic imaging relies on the detection of ultrasonic waves induced by laser pulse excitations to map optical absorption in biological tissue. A tomographic geometry employing a conventional ultrasound linear detector array for volumetric optoacoustic imaging is reported. The geometry is based on a translate-rotate scanning motion of the detector array, and capitalizes on the geometrical characteristics of the transducer assembly to provide a large solid angular detection aperture. A system for three-dimensional whole-body optoacoustic tomography of small animals is implemented. The detection geometry was tested using a 128-element linear array (5.0∕7.0 MHz, Acuson L7, Siemens), moved by steps with a rotation∕translation stage assembly. Translation and rotation range of 13.5 mm and 180°, respectively, were implemented. Optoacoustic emissions were induced in tissue-mimicking phantoms and ex vivo mice using a pulsed laser operating in the near-IR spectral range at 760 nm. Volumetric images were formed using a filtered backprojection algorithm. The resolution of the optoacoustic tomography system was measured to be better than 130 μm in-plane and 330 μm in elevation (full width half maximum), and to be homogenous along a 15 mm diameter cross section due to the translate-rotate scanning geometry. Whole-body volumetric optoacoustic images of mice were performed ex vivo, and imaged organs and blood vessels through the intact abdominal and head regions were correlated to the mouse anatomy. Overall, the feasibility of three-dimensional and high-resolution whole-body optoacoustic imaging of small animal using a conventional linear array was demonstrated. Furthermore, the scanning geometry may be used for other linear arrays and is therefore expected to be of great interest for optoacoustic tomography at macroscopic and mesoscopic scale. Specifically, conventional detector arrays with higher central frequencies may be investigated.

  7. Volume and planar gated cardiac magnetic resonance imaging: a correlative study of normal anatomy with Thallium-201 SPECT and cadaver sections

    International Nuclear Information System (INIS)

    Go, R.T.; MacIntyre, W.J.; Yeung, H.N.

    1984-01-01

    Magnetic resonance (MR) gated cardiac imaging was performed in ten subjects using a prototype 0.15-T resistive magnet imaging system. Volume and planar imaging techniques utilizing saturation recovery, proton TI-weighted relaxation time pulse sequences produced images of the heart and great vessels with exquisite anatomic detail that showed excellent correlation with cadaver sections of the heart. The left ventricular myocardial segments also showed excellent correlation with cadaver sections of the heart. The left ventricular myocardial segments also showed excellent correlation with the thallium-201 cardiac single photon emission computed tomography images. Volume acquisition allowed postprocessing selection of tomographic sections in various orientations to optimize visualization of a particular structure of interest. The excellent spatial and contrast resolution afforded by MR volume imaging, which does not involve the use of ionizing radiation and iodinated contrast material, should assure it a significant role in the diagnostic assessment of the cardiovascular system

  8. Evaluation of scatter limitation correction: a new method of correcting photopenic artifacts caused by patient motion during whole-body PET/CT imaging.

    Science.gov (United States)

    Miwa, Kenta; Umeda, Takuro; Murata, Taisuke; Wagatsuma, Kei; Miyaji, Noriaki; Terauchi, Takashi; Koizumi, Mitsuru; Sasaki, Masayuki

    2016-02-01

    Overcorrection of scatter caused by patient motion during whole-body PET/computed tomography (CT) imaging can induce the appearance of photopenic artifacts in the PET images. The present study aimed to quantify the accuracy of scatter limitation correction (SLC) for eliminating photopenic artifacts. This study analyzed photopenic artifacts in (18)F-fluorodeoxyglucose ((18)F-FDG) PET/CT images acquired from 12 patients and from a National Electrical Manufacturers Association phantom with two peripheral plastic bottles that simulated the human body and arms, respectively. The phantom comprised a sphere (diameter, 10 or 37 mm) containing fluorine-18 solutions with target-to-background ratios of 2, 4, and 8. The plastic bottles were moved 10 cm posteriorly between CT and PET acquisitions. All PET data were reconstructed using model-based scatter correction (SC), no scatter correction (NSC), and SLC, and the presence or absence of artifacts on the PET images was visually evaluated. The SC and SLC images were also semiquantitatively evaluated using standardized uptake values (SUVs). Photopenic artifacts were not recognizable in any NSC and SLC image from all 12 patients in the clinical study. The SUVmax of mismatched SLC PET/CT images were almost equal to those of matched SC and SLC PET/CT images. Applying NSC and SLC substantially eliminated the photopenic artifacts on SC PET images in the phantom study. SLC improved the activity concentration of the sphere for all target-to-background ratios. The highest %errors of the 10 and 37-mm spheres were 93.3 and 58.3%, respectively, for mismatched SC, and 73.2 and 22.0%, respectively, for mismatched SLC. Photopenic artifacts caused by SC error induced by CT and PET image misalignment were corrected using SLC, indicating that this method is useful and practical for clinical qualitative and quantitative PET/CT assessment.

  9. What is the most accurate whole-body imaging modality for assessment of local and distant recurrent disease in colorectal cancer? A meta-analysis. Imaging for recurrent colorectal cancer

    International Nuclear Information System (INIS)

    Maas, Monique; Lambregts, Doenja M.J.; Rutten, Iris J.G.; Cappendijk, Vincent C.; Beets-Tan, Regina G.H.; Nelemans, Patty J.; Beets, Geerard L.

    2011-01-01

    The objective of this study was to compare the diagnostic performance of positron emission tomography (PET), PET/CT, CT and MRI as whole-body imaging modalities for the detection of local and/or distant recurrent disease in colorectal cancer (CRC) patients who have a (high) suspicion of recurrent disease, based on clinical findings or rise in carcinoembryonic antigen (CEA). A meta-analysis was undertaken. PubMed and Embase were searched for studies on the accuracy of whole-body imaging for patients with suspected local and/or distant recurrence of their CRC. Additionally, studies had to have included at least 20 patients with CRC and 2 x 2 contingency tables had to be provided or derivable. Articles evaluating only local recurrence or liver metastasis were excluded. Summary receiver-operating characteristic (ROC) curves were constructed from the data on sensitivity and specificity of individual studies and pooled estimates of diagnostic odds ratios (DORs) and areas under the ROC curve (AUCs) were calculated. To test for heterogeneity the Cochran Q test was used. Fourteen observational studies were included which evaluated PET, PET/CT, CT and/or MRI. Study results were available in 12 studies for PET, in 5 studies for CT, in 5 studies for PET/CT and in 1 study for MRI. AUCs for PET, PET/CT and CT were 0.94 (0.90-0.97), 0.94 (0.87-0.98) and 0.83 (0.72-0.90), respectively. In patient based analyses PET/CT had a higher diagnostic performance than PET with an AUC of 0.95 (0.89-0.97) for PET/CT vs 0.92 (0.86-0.96) for PET. Both whole-body PET and PET/CT are very accurate for the detection of local and/or distant recurrent disease in CRC patients with a (high) suspicion of recurrent disease. CT has the lowest diagnostic performance. This difference is probably mainly due to the lower accuracy of CT for detection of extrahepatic metastases (including local recurrence). For clinical practice PET/CT might be the modality of choice when evaluating patients with a (high

  10. SlideJ: An ImageJ plugin for automated processing of whole slide images.

    Science.gov (United States)

    Della Mea, Vincenzo; Baroni, Giulia L; Pilutti, David; Di Loreto, Carla

    2017-01-01

    The digital slide, or Whole Slide Image, is a digital image, acquired with specific scanners, that represents a complete tissue sample or cytological specimen at microscopic level. While Whole Slide image analysis is recognized among the most interesting opportunities, the typical size of such images-up to Gpixels- can be very demanding in terms of memory requirements. Thus, while algorithms and tools for processing and analysis of single microscopic field images are available, Whole Slide images size makes the direct use of such tools prohibitive or impossible. In this work a plugin for ImageJ, named SlideJ, is proposed with the objective to seamlessly extend the application of image analysis algorithms implemented in ImageJ for single microscopic field images to a whole digital slide analysis. The plugin has been complemented by examples of macro in the ImageJ scripting language to demonstrate its use in concrete situations.

  11. Whole-body computed tomography in trauma patients: optimization of the patient scanning position significantly shortens examination time while maintaining diagnostic image quality

    Directory of Open Access Journals (Sweden)

    Hickethier T

    2018-05-01

    Full Text Available Tilman Hickethier,1,* Kamal Mammadov,1,* Bettina Baeßler,1 Thorsten Lichtenstein,1 Jochen Hinkelbein,2 Lucy Smith,3 Patrick Sven Plum,4 Seung-Hun Chon,4 David Maintz,1 De-Hua Chang1 1Department of Radiology, University Hospital of Cologne, Cologne, Germany; 2Department of Anesthesiology and Intensive Care Medicine, University Hospital of Cologne, Cologne, Germany; 3Faculty of Medicine, Memorial University of Newfoundland, St. John’s, Canada; 4Department of General, Visceral and Cancer Surgery, University Hospital of Cologne, Cologne, Germany *These authors contributed equally to this work Background: The study was conducted to compare examination time and artifact vulnerability of whole-body computed tomographies (wbCTs for trauma patients using conventional or optimized patient positioning. Patients and methods: Examination time was measured in 100 patients scanned with conventional protocol (Group A: arms positioned alongside the body for head and neck imaging and over the head for trunk imaging and 100 patients scanned with optimized protocol (Group B: arms flexed on a chest pillow without repositioning. Additionally, influence of two different scanning protocols on image quality in the most relevant body regions was assessed by two blinded readers. Results: Total wbCT duration was about 35% or 3:46 min shorter in B than in A. Artifacts in aorta (27 vs 6%, liver (40 vs 8% and spleen (27 vs 5% occurred significantly more often in B than in A. No incident of non-diagnostic image quality was reported, and no significant differences for lungs and spine were found. Conclusion: An optimized wbCT positioning protocol for trauma patients allows a significant reduction of examination time while still maintaining diagnostic image quality. Keywords: CT scan, polytrauma, acute care, time requirement, positioning

  12. [Detoxification effects of two drugs in thallium -poisoned mice].

    Science.gov (United States)

    Wang, Ying; He, Yue-zhong; Zhang, Xi-gang

    2012-06-01

    To observe the thallium eliminating effect of prussian blue, pentetate zinc trisodium (Zn-DTPA), and their combined use in the treatment of acute thallium poisoning in mice. Thallium poisoned mice were reproduced by oral administration of 0.2 ml thallous nitrate (3 mg/ml). They were assigned randomly to four groups according to the random number table method, namely, model group, prussian blue group, Zn-DTPA group and the combination therapy group, with 10 mice in each group. Prussian blue was administered orally [4.52 g×kg(-1)×d(-1), total four times], and Zn-DTPA was injected intraperitoneally [500 mg×kg(-1)×d(-1), one time]4 hours after giving thallium. The dosage of both drugs in combination treatment was as the same as described above. After treatment for 5 days, all the animals were sacrificed. Brain, intestine, kidney and liver of 1 mouse from each group were collected for pathological examination to observe the necrosis. Thallium contents of blood, brain, urine and feces from the other mice were determined. Pathological examination showed that the damage to intestine, kidney and liver was less obvious in treatment group compared with those of the model group. The effect was most obvious in the combination treatment group. However, brain damage was slightly improved. Thallium content in blood (mg/ml) of prussian blue group and the combination treatment group decreased obviously compared with the model group, and the decrease was more obvious in the combination treatment group (0.05 ± 0.01 vs. 0.18 ± 0.02). Thallium content in urine (mg/ml) and feces (mg/kg) was significantly increased after treatment, and the thallium elimination was most significant in the combined treatment group (urine: 11.34 ± 0.81 vs. 0.02 ± 0.01, feces: 13.11 ± 1.84 vs. 0.21 ± 0.07, both P Thallium content in brain was similar among all the groups. The single and combined use of prussian blue and Zn-DTPA could reduce the damage in intestine, kidney and liver. Combined use of

  13. Whole body MR in patients with multiple myeloma

    International Nuclear Information System (INIS)

    Piekarek, A.; Sosnowski, P.; Nowicki, A.; Komarnicki, M.

    2009-01-01

    Background: Multiple myeloma is a cancer of plasma cells which leads to bone marrow infiltration. Aim: Whole-body MR is the most sensitive imaging method available to detect multiple myeloma lesions. Ma terial and methods: MR scans were performed in 100 patients with multiple myeloma who were receiving treatment in the Haematology Clinic in Poznan in the years 2005 - 2006. Whole-body MR scans were performed with general coil 1.0 T in STIR sequences and T1 sequences, in coronal and sagittal planes with scanning area covering the head, neck, trunk and the limbs (FOV for specific regions was 36 -48 cm). The bone lesions were classified as focal (monofocal/multifocal lesions), infiltrative, mixed and 'salt and pepper' type. Depending on the size of the lesions the patients were included in one of three groups according to Salmon-Durie Plus classification. Results: Four main types of multiple myeloma were distinguished based on MR scans: focal (48 patients; monofocal in 10 patients), infiltrative (17 patients), mixed type (19 patients) and 'salt and pepper' type (4 patients). The remaining 12 patients had no multiple myeloma lesions in the bone marrow. Additionally, in 18% of patients a soft tissue mass could be observed. According to Salmon-Durie Plus categorisation 27 subjects were classified as having stage I, 16 patients stage and 57 patients stage III disease. In 12% of patients MR data changed the disease staging. Conclusions: WB MR is a sensitive and effective diagnostic method with an important impact on staging and further treatment of multiple myeloma. (authors)

  14. Survey: interpolation methods for whole slide image processing.

    Science.gov (United States)

    Roszkowiak, L; Korzynska, A; Zak, J; Pijanowska, D; Swiderska-Chadaj, Z; Markiewicz, T

    2017-02-01

    Evaluating whole slide images of histological and cytological samples is used in pathology for diagnostics, grading and prognosis . It is often necessary to rescale whole slide images of a very large size. Image resizing is one of the most common applications of interpolation. We collect the advantages and drawbacks of nine interpolation methods, and as a result of our analysis, we try to select one interpolation method as the preferred solution. To compare the performance of interpolation methods, test images were scaled and then rescaled to the original size using the same algorithm. The modified image was compared to the original image in various aspects. The time needed for calculations and results of quantification performance on modified images were also compared. For evaluation purposes, we used four general test images and 12 specialized biological immunohistochemically stained tissue sample images. The purpose of this survey is to determine which method of interpolation is the best to resize whole slide images, so they can be further processed using quantification methods. As a result, the interpolation method has to be selected depending on the task involving whole slide images. © 2016 The Authors Journal of Microscopy © 2016 Royal Microscopical Society.

  15. EXPLORER: Changing the molecular imaging paradigm with total-body PET/CT (Conference Presentation)

    Science.gov (United States)

    Cherry, Simon R.; Badawi, Ramsey D.; Jones, Terry

    2016-04-01

    Positron emission tomography (PET) is the highest sensitivity technique for human whole-body imaging studies. However, current clinical PET scanners do not make full use of the available signal, as they only permit imaging of a 15-25 cm segment of the body at one time. Given the limited sensitive region, whole-body imaging with clinical PET scanners requires relatively long scan times and subjects the patient to higher than necessary radiation doses. The EXPLORER initiative aims to build a 2-meter axial length PET scanner to allow imaging the entire subject at once, capturing nearly the entire available PET signal. EXPLORER will acquire data with ~40-fold greater sensitivity leading to a six-fold increase in reconstructed signal-to-noise ratio for imaging the total body. Alternatively, total-body images with the EXPLORER scanner will be able to be acquired in ~30 seconds or with ~0.15 mSv injected dose, while maintaining current PET image quality. The superior sensitivity will open many new avenues for biomedical research. Specifically for cancer applications, high sensitivity PET will enable detection of smaller lesions. Additionally, greater sensitivity will allow imaging out to 10 half-lives of positron emitting radiotracers. This will enable 1) metabolic ultra-staging with FDG by extending the uptake and clearance time to 3-5 hours to significantly improve contrast and 2) improved kinetic imaging with short-lived radioisotopes such as C-11, crucial for drug development studies. Frequent imaging studies of the same subject to study disease progression or to track response to therapy will be possible with the low dose capabilities of the EXPLORER scanner. The low dose capabilities will also open up new imaging possibilities in pediatrics and adolescents to better study developmental disorders. This talk will review the basis for developing total-body PET, potential applications, and review progress to date in developing EXPLORER, the first total-body PET scanner.

  16. Human whole body cold adaptation.

    Science.gov (United States)

    Daanen, Hein A M; Van Marken Lichtenbelt, Wouter D

    2016-01-01

    Reviews on whole body human cold adaptation generally do not distinguish between population studies and dedicated acclimation studies, leading to confusing results. Population studies show that indigenous black Africans have reduced shivering thermogenesis in the cold and poor cold induced vasodilation in fingers and toes compared to Caucasians and Inuit. About 40,000 y after humans left Africa, natives in cold terrestrial areas seems to have developed not only behavioral adaptations, but also physiological adaptations to cold. Dedicated studies show that repeated whole body exposure of individual volunteers, mainly Caucasians, to severe cold results in reduced cold sensation but no major physiological changes. Repeated cold water immersion seems to slightly reduce metabolic heat production, while repeated exposure to milder cold conditions shows some increase in metabolic heat production, in particular non-shivering thermogenesis. In conclusion, human cold adaptation in the form of increased metabolism and insulation seems to have occurred during recent evolution in populations, but cannot be developed during a lifetime in cold conditions as encountered in temperate and arctic regions. Therefore, we mainly depend on our behavioral skills to live in and survive the cold.

  17. Human fatality due to thallium poisoning: autopsy, microscopy, and mass spectrometry assays.

    Science.gov (United States)

    Li, Shangxun; Huang, Wen; Duan, Yijie; Xing, Jingjun; Zhou, Yiwu

    2015-01-01

    Thallium has been responsible for many intoxications since its discovery; however, toxicological profiles for thallium in human fatalities have not been updated recently. Autopsy, microscopic investigations, and toxicological analyses were performed on a married couple who died from thallium sulfate intended homicidal poisoning. The distribution of thallium was established by inductively coupled plasma mass spectrometry with hair samples showing the highest thallium concentration. Electron microscopy revealed a dystrophic condition of hair with disorganized cuticle and atrophy of the hair bulb. Thallium interacts with cells at different levels, with prominent ultrastructural injuries in the mitochondria and endoplasmic reticulum, and high concentration of electron dense granules observed in the cytoplasm and mitochondria of several organs. Alopecia, toxic encephalopathy, and peripheral neuropathy were diagnosed in the victims and suggested to be crucial implications for thallium poisoning. The analytical procedures used in this case are of considerable forensic importance in the diagnosis of thallium poisoning. © 2014 American Academy of Forensic Sciences.

  18. Whole-Body and Hepatic Insulin Resistance in Obese Children

    Science.gov (United States)

    Ibarra-Reynoso, Lorena del Rocío; Pisarchyk, Liudmila; Pérez-Luque, Elva Leticia; Garay-Sevilla, Ma. Eugenia; Malacara, Juan Manuel

    2014-01-01

    Background Insulin resistance may be assessed as whole body or hepatic. Objective To study factors associated with both types of insulin resistance. Methods Cross-sectional study of 182 obese children. Somatometric measurements were registered, and the following three adiposity indexes were compared: BMI, waist-to-height ratio and visceral adiposity. Whole-body insulin resistance was evaluated using HOMA-IR, with 2.5 as the cut-off point. Hepatic insulin resistance was considered for IGFBP-1 level quartiles 1 to 3 (HOMA-IR was negatively associated with IGFBP-1 and positively associated with BMI, triglycerides, leptin and mother's BMI. Girls had increased HOMA-IR. IGFBP-1 was negatively associated with waist-to-height ratio, age, leptin, HOMA-IR and IGF-I. We did not find HOMA-IR or IGFBP-1 associated with fatty liver. Conclusion In school-aged children, BMI is the best metric to predict whole-body insulin resistance, and waist-to-height ratio is the best predictor of hepatic insulin resistance, indicating that central obesity is important for hepatic insulin resistance. The reciprocal negative association of IGFBP-1 and HOMA-IR may represent a strong interaction of the physiological processes of both whole-body and hepatic insulin resistance. PMID:25411786

  19. Development of a low-cost whole body counter

    International Nuclear Information System (INIS)

    Smith, M.H.; Gross, G.P.

    1991-01-01

    This paper documents the construction and calibration of a whole-body counter for the Radiation Safety Office of the Mayo Clinic in Rochester, MN. Changes in the federal regulations may require improved documentation of internal dose for radiation workers. A relatively inexpensive and simple chair-type whole-body counter may suit the needs of many organizations for in vivo assessment of gamma emitting radionuclides. A simple calibration phantom and a spreadsheet computer program were developed in conjunction with the counter. The spreadsheet can be used to calculate an estimate of committed effective dose equivalent based on activity in a subject and data from ICRP Publication 30. Using a count time of 10 minutes, the counter's minimum detectable activity ranged from 370 Bq to 1,110 Bq for 60 Co and 57 Co respectively. Other institutions will be able to assemble whole-body counters at low cost, often from surplus components. The spreadsheet is easily adapted to the needs of any institution and uses current methodology to estimate internal dose

  20. Prediction of single versus multivessel disease following myocardial infarction using 201-thallium scintigraphy and electrocardiographic stress testing

    International Nuclear Information System (INIS)

    Weiss, R.J.; Morise, A.P.; Raabe, D.S. Jr.; Sbarbaro, J.A.

    1983-01-01

    Fifty patients were evaluated who suffered a single myocardial infarction with graded electrocardiographic stress testing, 201-thallium myocardial perfusion imaging and coronary angiography to assess the role of noninvasive indices as predictors of single versus multivessel coronary artery disease. Multivessel involvement was defined angiographically as the presence of two or more major coronary arteries with at least a 70% intraluminal diameter narrowing. Multivessel disease was defined scintigraphically as the presence of stress and/or redistribution perfusion defects in the distribution of more than one coronary artery. The results of stress electrocardiography were not useful in differentiating patients with single (9/16 positive) versus multivessel (22/34 positive) disease. The degree of exercise-induced ST-segment depression was also not helpful. Stress 201-thallium imaging did offer limited additional information with correct predictions of multivessel disease in 21 of 26 patients. Predictions of single-vessel disease were accurate in 11 of 24 patients. Eleven of these 13 incorrect predictions of single-vessel disease were due to the relative insensitivity of the thallium stress image to perceive defect in the anterior wall when the left anterior descending artery had significant obstruction at catheterization. Further refinements of stress perfusion imaging are needed before this method can be used to reliably separate patients with single and multivessel disease after myocardial infarction

  1. SlideJ: An ImageJ plugin for automated processing of whole slide images.

    Directory of Open Access Journals (Sweden)

    Vincenzo Della Mea

    Full Text Available The digital slide, or Whole Slide Image, is a digital image, acquired with specific scanners, that represents a complete tissue sample or cytological specimen at microscopic level. While Whole Slide image analysis is recognized among the most interesting opportunities, the typical size of such images-up to Gpixels- can be very demanding in terms of memory requirements. Thus, while algorithms and tools for processing and analysis of single microscopic field images are available, Whole Slide images size makes the direct use of such tools prohibitive or impossible. In this work a plugin for ImageJ, named SlideJ, is proposed with the objective to seamlessly extend the application of image analysis algorithms implemented in ImageJ for single microscopic field images to a whole digital slide analysis. The plugin has been complemented by examples of macro in the ImageJ scripting language to demonstrate its use in concrete situations.

  2. Selective Thallium (I Ion Sensor Based on Functionalised ZnO Nanorods

    Directory of Open Access Journals (Sweden)

    Z. H. Ibupoto

    2012-01-01

    Full Text Available Well controlled in length and highly aligned ZnO nanorods were grown on the gold-coated glass substrate by hydrothermal growth method. ZnO nanorods were functionalised with selective thallium (I ion ionophore dibenzyldiaza-18-crown-6 (DBzDA18C6. The thallium ion sensor showed wide linear potentiometric response to thallium (I ion concentrations ( M to  M with high sensitivity of 36.87 ± 1.49 mV/decade. Moreover, thallium (I ion demonstrated fast response time of less than 5 s, high selectivity, reproducibility, storage stability, and negligible response to common interferents. The proposed thallium (I ion-sensor electrode was also used as an indicator electrode in the potentiometric titration, and it has shown good stoichiometric response for the determination of thallium (I ion.

  3. Adolescence and Body Image.

    Science.gov (United States)

    Weinshenker, Naomi

    2002-01-01

    Discusses body image among adolescents, explaining that today's adolescents are more prone to body image distortions and dissatisfaction than ever and examining the historical context; how self-image develops; normative discontent; body image distortions; body dysmorphic disorder (BDD); vulnerability of boys (muscle dysmorphia); who is at risk;…

  4. Whole-body magnetic resonance angiography for presurgical planning of free-flap head and neck reconstruction

    International Nuclear Information System (INIS)

    Kramer, Manuel; Nkenke, Emeka; Kikuchi, Keiichi; Schwab, Siegfried A.; Janka, Rolf; Uder, Michael; Lell, Michael

    2012-01-01

    Objectives: Aim of the study was to evaluate if a whole-body magnetic resonance angiography (MRA) protocol meets the requirements to evaluate the donor and host site target vessels for planning of microvascular head and neck reconstructions. Patients and methods: In 20 patients, scheduled for reconstruction of the mandible with fibular free flaps, contrast-enhanced whole-body MRA was performed prior to surgery. 32-Channel 1.5-T MR angiograms were acquired using a 2-step contrast (gadobutrol) injection scheme to visualize the arterial vasculature from head to feet. Maximum intensity projection and multiplanar reconstruction technique was employed to visualize MRA data. For image evaluation the arterial tree was divided into 51 segments. The presence of artefacts impairing diagnostic quality was noted. Evaluable segments were assessed regarding the presence of stenoses >50% diameter reduction, occlusions or aneurysms. Results: No adverse reactions or complications occurred. Of 1020 vessel segments 1003 (98.3%) were evaluable. 36 stenoses >50%, 50 occlusions and one aneurysm were observed. In 21 of 40 lower limbs relevant atherosclerotic changes were depicted. Conclusion: Whole-body MRA proved to be a suitable three-dimensional, noninvasive, nonionising modality for preoperative evaluation of the entire arterial vasculature.

  5. Between-centre variability versus variability over time in DXA whole body measurements evaluated using a whole body phantom

    Energy Technology Data Exchange (ETDEWEB)

    Louis, Olivia [Department of Radiology, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)]. E-mail: olivia.louis@az.vub.ac.be; Verlinde, Siska [Belgian Study Group for Pediatric Endocrinology (Belgium); Thomas, Muriel [Belgian Study Group for Pediatric Endocrinology (Belgium); De Schepper, Jean [Department of Pediatrics, AZ-VUB, Vrije Universiteit Brussel, Laarbeeklaan 101, 1090 Brussel (Belgium)

    2006-06-15

    This study aimed to compare the variability of whole body measurements, using dual energy X-ray absorptiometry (DXA), among geographically distinct centres versus that over time in a given centre. A Hologic-designed 28 kg modular whole body phantom was used, including high density polyethylene, gray polyvinylchloride and aluminium. It was scanned on seven Hologic QDR 4500 DXA devices, located in seven centres and was also repeatedly (n = 18) scanned in the reference centre, over a time span of 5 months. The mean between-centre coefficient of variation (CV) ranged from 2.0 (lean mass) to 5.6% (fat mass) while the mean within-centre CV ranged from 0.3 (total mass) to 4.7% (total area). Between-centre variability compared well with within-centre variability for total area, bone mineral content and bone mineral density, but was significantly higher for fat (p < 0.001), lean (p < 0.005) and total mass (p < 0.001). Our results suggest that, even when using the same device, the between-centre variability remains a matter of concern, particularly where body composition is concerned.

  6. Submaximal exercise thallium-201 SPECT for assessment of interventional therapy in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Stewart, R.E.; Kander, N.; Juni, J.E.; Ellis, S.G.; O'Neill, W.W.; Schork, M.A.; Topol, E.J.; Schwaiger, M.

    1991-01-01

    Submaximal thallium-201 stress testing has been shown to provide important diagnostic and prognostic information in patients with acute myocardial infarction. The purpose of this investigation was to evaluate the diagnostic value of early submaximal stress testing and thallium-201 single photon emission computed tomography (SPECT) after interventional therapy. Scintigraphic results from 56 patients with infarctions, who underwent acute thrombolytic therapy, angioplasty, or both, were compared with late (6 weeks) functional outcome as assessed by radionuclide ventriculography and with results of discharge coronary angiography. A linear correlation was found between the extent of thallium-201 SPECT perfusion defect and late ventricular function (r = 0.74, p less than 0.01). Forty-two percent of patients with large SPECT perfusion defects had normal left ventricular ejection fractions, suggesting an overestimation of infarct size by early imaging. Sensitivity and specificity of thallium-201 SPECT for detection of coronary artery stenosis in noninfarct territories was 57% and 46%, respectively, indicating limited diagnostic definition of extent of underlying coronary artery disease. Results of follow-up coronary angiography showed a significant relationship between the size of the initial perfusion defect and early restenosis or reocclusion of the infarct artery. Thus the extent of early thallium-201 perfusion defects correlates with late functional outcome but appears to overestimate the degree of injury. Submaximal thallium-201 stress testing allows only limited characterization of underlying coronary artery disease. Early assessment of infarct size may identify a patient population at high risk for reocclusion of the infarct artery

  7. Incidental findings in healthy control research subjects using whole-body MRI

    International Nuclear Information System (INIS)

    Morin, S.H.X.; Cobbold, J.F.L.; Lim, A.K.P.; Eliahoo, J.; Thomas, E.L.; Mehta, S.R.; Durighel, G.; Fitzpatrick, J.; Bell, J.D.

    2009-01-01

    Aim: Magnetic resonance imaging (MRI) is a powerful clinical tool used increasingly in the research setting. We aimed to assess the prevalence of incidental findings in a sequential cohort of healthy volunteers undergoing whole-body MRI as part of a normal control database for imaging research studies. Materials and methods: 148 healthy volunteers (median age 36 years, range 21-69 years; 63.5% males, 36.5% females) were enrolled into a prospective observational study at a single hospital-based MRI research unit in London, UK. Individuals with a clinical illness, treated or under investigation were excluded from the study. Results: 43 (29.1%) scans were abnormal with a total of 49 abnormalities detected. Of these, 20 abnormalities in 19 patients (12.8%) were of clinical significance. The prevalence of incidental findings increased significantly with both increasing age and body mass index (BMI). Obese subjects had a fivefold greater risk of having an incidental abnormality on MRI (OR 5.4, CI 2.1-14.0). Conclusions: This study showed that more than one quarter of healthy volunteers have MR-demonstrable abnormalities. There was an increased risk of such findings in obese patients. This has ethical and financial implications for future imaging research, particularly with respect to informed consent and follow-up of those with abnormalities detected during the course of imaging studies.

  8. Analysis of whole-body vibration on rheological models for tissues

    Science.gov (United States)

    Neamţu, A.; Simoiu, D.; Nyaguly, E.; Crastiu, I.; Bereteu, L.

    2018-01-01

    Whole body vibrations have become a very popular method in recent years, both in physical therapy and in sports. This popularity is due to the fact that, as a result of analyzing the groups of subjects, the effects of small amplitude vibration and low frequency vibration, it was found an increase in the force developed by the feet, a hardening of bone strength or an increase in bone density. In this paper we propose to give a possible explanation of the stress relieving in muscle and/or bone after whole body vibration treatment. To do this we consider some rheological models which after whole body vibrations and after the analysis of their response lead to various experiments.

  9. VIP-Man: An image-based whole-body adult male model constructed from color photographs of the visible human project for multi-particle Monte Carlo calculations

    International Nuclear Information System (INIS)

    Xu, X.G.; Chao, T.C.; Bozkurt, A.

    2000-01-01

    Human anatomical models have been indispensable to radiation protection dosimetry using Monte Carlo calculations. Existing MIRD-based mathematical models are easy to compute and standardize, but they are simplified and crude compared to human anatomy. This article describes the development of an image-based whole-body model, called VIP-Man, using transversal color photographic images obtained from the National Library of Medicine's Visible Human Project for Monte Carlo organ dose calculations involving photons, electron, neutrons, and protons. As the first of a series of papers on dose calculations based on VIP-Man, this article provides detailed information about how to construct an image-based model, as well as how to adopt it into well-tested Monte Carlo codes, EGS4, MCNP4B, and MCNPX

  10. Whole body vibration improves body mass, flexibility and strength in ...

    African Journals Online (AJOL)

    Objectives. This study aimed to determine the effectiveness of whole body vibration (WBV) training for promoting healthrelated physical fitness in sedentary adults. Design. A non-randomised sampling technique was used with an equivalent match-pair comparison group, pre- and posttest design. Volunteers were gathered ...

  11. Vibration and Noise in Magnetic Resonance Imaging of the Vocal Tract: Differences between Whole-Body and Open-Air Devices

    Directory of Open Access Journals (Sweden)

    Jiří Přibil

    2018-04-01

    Full Text Available This article compares open-air and whole-body magnetic resonance imaging (MRI equipment working with a weak magnetic field as regards the methods of its generation, spectral properties of mechanical vibration and acoustic noise produced by gradient coils during the scanning process, and the measured noise intensity. These devices are used for non-invasive MRI reconstruction of the human vocal tract during phonation with simultaneous speech recording. In this case, the vibration and noise have negative influence on quality of speech signal. Two basic measurement experiments were performed within the paper: mapping sound pressure levels in the MRI device vicinity and picking up vibration and noise signals in the MRI scanning area. Spectral characteristics of these signals are then analyzed statistically and compared visually and numerically.

  12. Measurements of whole-body radioactivity in the UK population

    International Nuclear Information System (INIS)

    Fenwick, J.D.; Boddy, K.; McKenzie, A.L.; Oxby, C.B.

    1992-01-01

    A national survey of whole-body radioactivity was undertaken. A mobile whole-body counter visited collaborating Medical Physics Departments and Hospitals in England and Wales. Data were also obtained from an installed whole-body counter at the West Cumberland Hospital, Whitehaven, and from a control site at Addenbrooke's Hospital, Cambridge. 1657 volunteer members of the public were measured, including 162 children. 36% of volunteers had been measured in a similar survey 2 years earlier, and showed between a two and five fold reduction in body radiocaesium. No radiocaesium was detected in 54% of people measured. Measurements showed a progressive fall over the course of the study, reaching a baseline of 0.3 Bq 137 Cs/gK. In 1989, the additional radiation dose incurred from radiocaesium varied from a maximum of 4.1 μSv in Cumbria to 1.5 μSv in the South East, compared with the average annual radiation dose of 2500 μSv due to all other causes. No other gamma-emitting radionuclides were found. Results are consistent with Chernobyl as the source of the radiocaesium detected. (author)

  13. The value and limitation thallium scintigraphy in the detection of coronary artery disease

    International Nuclear Information System (INIS)

    Khan, A.; Rehman, A.; Amin, W.; Khan, Z.A.; Ahmed, S.A.

    1986-01-01

    In this study we randomly selected 45 patients whose coronary angiograms were abnormal i.e. showing triple, double and single vessel disease out of a pool of 80 patients who had undergone stress thallium imaging and coronary angiography during the one year. Majority of these patients were males, their ages ranged between 34-54 years. Resting ECG's were normal in 25 patients, 15 patients had suffered inferior myocardial infraction and 5 had sustained anterior myocardial infraction in the past. Coronary angiography revealed triple vessel disease in 20 patients, double vessel disease in 15, and single vessel coronary artery disease in 10. We analysed their coronary angiograms and compared them with the scintigraphic finding. It is concluded that although thallium scanning has high sensitivity for detection of coronary artery disease in general, it has only moderate sensitivity for detection of stenosis in individual coronary arteries. In this study thallium scan identified 75% of RCA lesions, 66% of LAD lesions and 38% of circumflex lesions. The sensitivity is much higher in single vessel coronary artery disease. (author)

  14. Whole Slide Images for primary diagnostics in pathology

    NARCIS (Netherlands)

    Al-Janabi, S.

    2013-01-01

    Whole slide imaging is the process of digitizing glass slides resulting in the creation of Whole Slide Images (WSI). WSI are usually explored with the aid of an image viewer in a manner that closely simulates examining glass slides with a conventional microscope, permitting the manipulation of an

  15. Exercise-induced thallium-201 myocardial perfusion defects in angina pectoris without significant coronary artery stenosis

    International Nuclear Information System (INIS)

    Nakazato, Masayasu; Maruoka, Yuji; Sunagawa, Osahiko; Kinjo, Kunihiko; Tomori, Masayuki; Fukiyama, Koshiro

    1990-01-01

    We performed exercise thallium-201 myocardial scintigraphy in 32 patients with angina pectoris to study the incidence of perfusion defects, who had no significant organic stenosis on coronary angiography. None of them had myocardial infarction or cardiomyopathy. Thallium-201 myocardial scintigraphy and 12-lead ECG recording were performed during supine bicycle ergometer exercise. Perfusion defects in thallium-201 scintigrams in SPECT images were assessed during visual analysis by two observers. In the coronary angiograms obtained during intravenous infusion of nitroglycerin, the luminal diameter of 75% stenosis or less in the AHA classification was regarded as an insignificant organic stenosis. Myocardial perfusion defects in the thallium-201 scintigrams were detected in eight (25%) of the 32 patients. Six of these eight patients had variant angina documented during spontaneous attacks with ST elevations in standard 12-lead ECGs. Perfusion defects were demonstrated at the inferior or infero-posterior regions in six patients, one of whom had concomitant anteroseptal defect. The defects were not always accompanied by chest pain. All but one patient demonstrating inferior or inferoposterior defects showed ST depression in leads II, III and aV F on their ECGs, corresponding to inferior wall ischemia. The exception was a case with right bundle branch block. Thus, 25% of the patients with angina pectoris, who had no evidence of significant organic stenosis on their coronary angiograms, exhibited exercise-induced perfusion defects in their thallium-201 scintigrams. Coronary spasms might have caused myocardial ischemia in these patients. (author)

  16. Body Talk: Body Image Commentary on Queerty.com.

    Science.gov (United States)

    Schwartz, Joseph; Grimm, Josh

    2016-08-01

    In this study, we conducted a content analysis of 243 photographic images of men published on the gay male-oriented blog Queerty.com. We also analyzed 435 user-generated comments from a randomly selected 1-year sample. Focusing on images' body types, we found that the range of body types featured on the blog was quite narrow-the vast majority of images had very low levels of body fat and very high levels of muscularity. Users' body image-related comments typically endorsed and celebrated images; critiques of images were comparatively rare. Perspectives from objectification theory and social comparison theory suggest that the images and commentary found on the blog likely reinforce unhealthy body image in gay male communities.

  17. Oak Ridge National Laboratory whole-body counter: internal operating procedure manual

    International Nuclear Information System (INIS)

    Berger, C.D.; Lane, B.H.

    1982-08-01

    The general purpose of the ORNL Whole Body Counter is to provide a rapid estimation of the type and quantity of radionuclide deposited in the human body. This report contains a review of the equipment in use at the facility and the procedure for its operation, the standard procedure for performing a routine whole body count, and a discussion of interpretation of results

  18. ST segment/heart rate slope as a predictor of coronary artery disease: comparison with quantitative thallium imaging and conventional ST segment criteria

    International Nuclear Information System (INIS)

    Finkelhor, R.S.; Newhouse, K.E.; Vrobel, T.R.; Miron, S.D.; Bahler, R.C.

    1986-01-01

    The ST segment shift relative to exercise-induced increments in heart rate, the ST/heart rate slope (ST/HR slope), has been proposed as a more accurate ECG criterion for diagnosing significant coronary artery disease (CAD). Its clinical utility, with the use of a standard treadmill protocol, was compared with quantitative stress thallium (TI) and standard treadmill criteria in 64 unselected patients who underwent coronary angiography. The overall diagnostic accuracy of the ST/HR slope was an improvement over TI and conventional ST criteria (81%, 67%, and 69%). For patients failing to reach 85% of their age-predicted maximal heart rate, its diagnostic accuracy was comparable with TI (77% and 74%). Its sensitivity in patients without prior myocardial infarctions was equivalent to that of thallium (91% and 95%). The ST/HR slope was directly related to the angiographic severity (Gensini score) of CAD in patients without a prior infarction (r = 0.61, p less than 0.001). The ST/HR slope was an improved ECG criterion for diagnosing CAD and compared favorably with TI imaging

  19. [Nervous system involvement in three children poisoned with thallium].

    Science.gov (United States)

    Gergont, Aleksandra; Lankosz-Lauterbach, Janina; Pietrzyk, Jacek J; Kaciński, Marek

    2004-01-01

    Three children, aged 5, 10 and 16 years, poisoned with thallium were hospitalized. Two of them suffered from sensory-motor and third from sensory polyneuropathy and additionally in the youngest child severe encephalopathy was observed. The correlations between serum and urine thallium levels and the severity of the symptoms in the course of the disease were positive. The most severe symptoms and the highest thallium level were observed in the youngest child.

  20. Magnetic resonance imaging in familial hypertrophic cardiomyopathy associated with abnormal thallium perfusion and cardiac enzymes

    Energy Technology Data Exchange (ETDEWEB)

    Nishimura, Tsunehiko; Nagata, Seiki; Sakakibara, Hiroshi

    1988-05-01

    Gated magnetic resonance imaging (MRI) was performed in 6 patients with familial hypertrophic cardiomyopathy associated with abnormal thallium perfusion, and 12 patients with ordinary hypertrophic cardiomyopathy. The patients with ordinary hypertrophic cardiomyopathy and abnormal thickening of the septal wall and normal left ventricular dimensions, while the patients with familial hypertrophic cardiomyopathy had focal wall thinning (usually involving the apical-septal wall) and dilated left ventricle in addition to hypertrophied heart. The quantitative measurement for cardiac dimensions using MRI was similar to that found on echocardiography in all cases. In addition, inhomogeneous signal intensities at left ventricular wall were observed in 3 cases of familial hypertrophic cardiomyopathy, which may suggest the existence of myocardial fibrosis. Gated MRI should be performed for early detection and follow-up of hypertrophic cardiomyopathy, since some patients will progress from hypertrophic cardiomyopathy to dilated cardiomyopathy.