WorldWideScience

Sample records for wear silicone hydrogel

  1. Bacterial populations on 30-night extended wear silicone hydrogel lenses.

    Science.gov (United States)

    Keay, L; Willcox, M D; Sweeney, D F; Morris, C A; Harmis, N; Corrigan, K; Holden, B A

    2001-01-01

    Ocular infection and inflammation during hydrogel lens extended wear is often associated with colonization of the lenses with bacteria. This study compares colonization of a high Dk silicone hydrogel contact lens (lotrafilcon A) worn on a 30-night extended wear basis to a low Dk HEMA-based lens (etafilcon A) worn on a 6-night extended wear schedule. The group wearing the low Dk/t soft contact lens (n = 63) replaced their lenses weekly and the group wearing high Dk/t soft contact lenses replaced their lenses monthly (n = 64). Lens allocation was assigned randomly at enrollment. Worn lenses, from one eye only, were collected aseptically and placed in sterile vials. Microbial growth on various media was enumerated and the number of colony forming units (cfu) per lens was calculated in categories of normal ocular microbiota (such as coagulase-negative staphylococci and Propionibacterium spp.) and known ocular pathogens (such as Staphylococcus aureus and gram-negative bacteria). The proportion of samples colonized with these bacteria and the extent of colonization were compared between the two groups. The proportion of sterile lenses was calculated, and the types of bacteria on each lens group were compared. No differences between the low and high Dk/t Soft contact lens groups were observed in the proportion of lenses colonized by Propionibacterium spp. (48% vs 43%, P = 0.4) or coagulase-negative staphylococci (47% vs 54%, P = 0.2). Similarly, no differences were found for lenses colonized by S. aureus (0% vs 2%, P = 0.1) or gram-negative bacteria (3% vs 2%, P = 0.8). The types of bacteria isolated from the high and low Dk/t lenses were similar. There were no differences in the number of sterile samples (28% vs 27%, P = 0.8) from each group. These findings suggest that high Dk/t silicone hydrogel materials are colonized by similar numbers and types of microorganisms during extended wear compared to HEMA-based material. Most lenses were colonized by commensal bacteria

  2. A Case of Atypical Mucin Balls Wearing Extended Wear of Silicone Hydrogel Lens for Therapeutic Use

    Directory of Open Access Journals (Sweden)

    Yusuke Matsuzaki

    2013-01-01

    Full Text Available A 25-year-old man visited our hospital showing atopic conjunctivitis and corneal shield ulcer on his left eye. Although eye drops of 0.1% of betamethasone sodium phosphate and 0.1% of hyaluronic acid ophthalmic solution were prescribed, calcific corneal opacities developed. The corrected visual acuity decreased to 6/20 in Snellen chart. After corneal epithelial exfoliation, removal of calcific corneal opacity was scrubbed with MQA soaked in 0.05 M of ethylenediaminetetraacetic acid (EDTA. After washing the eye with 200 mL of physiological saline, a silicon hydrogel lens, PureVision (balafilcon A, was inserted to obtain pain relief for the therapeutic use. At postoperative day 11, mucin balls were found between cornea and contact lens and stained by rose bengal dye. One of them was atypically larger than usual, and the major axis was approximately 1.5 mm. Wearing lens was stopped, and all of mucin balls and corneal staining were disappeared at postoperative day. Little corneal opacity remained, and visual acuity after surgery recovered to 14/20 at five months.

  3. Effect of prophylactic antibiotic drops on ocular microbiota and physiology during silicone hydrogel lens wear.

    Science.gov (United States)

    Ozkan, Jerome; Zhu, Hua; Gabriel, Manal; Holden, Brien A; Willcox, Mark D P

    2012-03-01

    Bacterial contamination of the contact lens surface has been demonstrated to cause corneal infiltrative events. A reduction in the rate of bacterially driven corneal infiltrative events associated with lens wear is one of the major goals of the contact lens industry. There is a concern over the potential of any antimicrobial strategy that there will be unwanted changes to the ocular microbiota or the development of resistance to the antimicrobial. The aim of this study was to investigate the effect of prophylactic topical antibiotic instillation during continuous wear of silicone hydrogel lenses on the normal ocular microbiota, the throat microbiota, and the ocular physiology. Forty-two male subjects were dispensed with lotrafilcon A silicone hydrogel contact lenses for a 3-month, 30 night continuous wear, monthly replacement trial. Subjects were randomized into either tobramycin 0.3% (test) or saline (control) drop group. Two drops were instilled into each eye on waking and before sleep. At monthly visits, lenses were collected aseptically, and ocular and throat swabs were performed, followed by standard microbial recovery and identifications. Any corneal infiltrative event at scheduled or unscheduled visits was recorded. Numbers of microbes recovered from eye swabs from the tobramycin (test) group were significantly lower than the control (p = 0.01). Gram-positive cocci were recovered less frequently from the test group (p = 0.001). There were no significant differences in the numbers and types of microbes recovered from lens samples, or the contamination rate of the lenses between the two groups. There were no changes in the numbers of fungi or bacteria from throat swabs. There was no evidence of changes to resistance profile of microbes in the throat. More eye swabs from the test group (68.5%) were culture-negative than swabs from control (46.5%; p = 0.002). The test group had less corneal staining superiorly (0.0 ± 0.0 vs. 0.3 ± 0.4; p = 0.025) but increased

  4. Differences in Dry Eye Questionnaire Symptoms in Two Different Modalities of Contact Lens Wear: Silicone-Hydrogel in Daily Wear Basis and Overnight Orthokeratology

    Directory of Open Access Journals (Sweden)

    Nery García-Porta

    2016-01-01

    Full Text Available Purpose. To compare the ocular surface symptoms and signs in an adult population of silicone-hydrogel (Si-Hy contact lens (CL wearers with another modality of CL wear, overnight orthokeratology (OK. Materials and Methods. This was a prospective and comparative study in which 31 myopic subjects were fitted with the same Si-Hy CL and 23 underwent OK treatment for 3 months. Dry eye questionnaire (DEQ was filled in at the beginning of the study and then after 15 days, 1 month, and 3 months using each CL modality. The tear quality was evaluated with noninvasive tear break-up time. Tear production was measured with Schirmer test. Tear samples were collected with Schirmer strips being frozen to analyze the dinucleotide diadenosine tetraphosphate (Ap4A concentration with High-Performance Liquid Chromatography (HPLC. Results. After refitting with ortho-k, a reduction in discomfort and dryness symptoms at the end of the day (p<0.05, χ2 was observed. No significant changes were observed in Ap4A concentration in any group. Bulbar redness, limbal redness, and conjunctival staining increased significantly in the Si-Hy group (p<0.05, Kruskal–Wallis test. Conclusion. Discomfort and dryness symptoms at the end of the day are lower in the OK CL group than in the Si-Hy CL group.

  5. Differences in Dry Eye Questionnaire Symptoms in Two Different Modalities of Contact Lens Wear: Silicone-Hydrogel in Daily Wear Basis and Overnight Orthokeratology

    Science.gov (United States)

    Rico-del-Viejo, Laura; Martin-Gil, Alba

    2016-01-01

    Purpose. To compare the ocular surface symptoms and signs in an adult population of silicone-hydrogel (Si-Hy) contact lens (CL) wearers with another modality of CL wear, overnight orthokeratology (OK). Materials and Methods. This was a prospective and comparative study in which 31 myopic subjects were fitted with the same Si-Hy CL and 23 underwent OK treatment for 3 months. Dry eye questionnaire (DEQ) was filled in at the beginning of the study and then after 15 days, 1 month, and 3 months using each CL modality. The tear quality was evaluated with noninvasive tear break-up time. Tear production was measured with Schirmer test. Tear samples were collected with Schirmer strips being frozen to analyze the dinucleotide diadenosine tetraphosphate (Ap4A) concentration with High-Performance Liquid Chromatography (HPLC). Results. After refitting with ortho-k, a reduction in discomfort and dryness symptoms at the end of the day (p < 0.05, χ2) was observed. No significant changes were observed in Ap4A concentration in any group. Bulbar redness, limbal redness, and conjunctival staining increased significantly in the Si-Hy group (p < 0.05, Kruskal–Wallis test). Conclusion. Discomfort and dryness symptoms at the end of the day are lower in the OK CL group than in the Si-Hy CL group. PMID:27689073

  6. Daily Wear Contact Lenses Manufactured in Etafilcon A Are Noninferior to Two Silicone Hydrogel Lens Types With Respect to Hypoxic Stress.

    Science.gov (United States)

    Szczotka-Flynn, Loretta B; Debanne, Sara; Benetz, Beth Ann; Wilson, Tawnya; Brennan, Noel

    2016-10-20

    This study hypothesized that a traditional high-water contact lens of moderate oxygen transmissibility (Dk/t) is noninferior to common silicone hydrogel (SH) lenses worn for daily wear with respect to measures of hypoxic stress. Thirty-six habitual contact lens wearers completed wear of three lens types worn in a randomized order: etafilcon A (ACUVUE 2, control), lotrafilcon B (Air Optix Aqua), and comfilcon A (Biofinity). Central corneal thickness (CT) and limbal hyperemia were measured >2 hr after waking and after 6 to 8 hr of wear on days 1 and 7. Endothelial bleb formation was measured on day 1 of each lens type. Noninferiority of etafilcon A, with respect to the other two lens types, was assumed if the following difference margins of equivalence were met: confidence interval [0.4%-1.3%]) and 0.75% at day 7 (0.3%-1.2%). The difference in mean swelling between etafilcon A and comfilcon A was 0.37% at day 1 (-0.1% to 0.8%) and 0.53% at day 7 (0.1%-1.0%). For limbal redness, etafilcon A fell within 0.1 grade of lotrafilcon B and 0.18 grade of comfilcon A. For endothelial bleb formation, etafilcon A fell within 0.45% of lotrafilcon B and 0.23% of comfilcon A. The etafilcon A control lens resulted in corneal deswelling throughout the day as did the SH lens types. Limbal hyperemia and endothelial bleb formation with all lenses were negligible, and noninferiority assumptions were met between the lens types for all outcomes. Equivalence of etafilcon A with respect to the two SH lenses for three measures of hypoxic stress was demonstrated.

  7. Refractive behavior changes with six months daily wear of high and low oxygen permeability hydrogel contact lenses

    Directory of Open Access Journals (Sweden)

    W.D.H. Gillan

    2006-01-01

    Full Text Available Introduction: The investigation of myopia and soft contact lenses is not new. Many reports show  that  the  wearing  of  silicone  hydrogel lenses as opposed to conventional disposable hydrogel lenses results in little progression of myopia in the eyes wearing silicone hydrogels. Method: Six subjects wore a silicone hydro-gel lens on one eye while the other eye wore a habitual disposable hydrogel lens for six months of daily wear. Fifty measurements of refractive state in each eye were taken prior to the subjects wearing a silicone lens in one eye and a conven-tional hydrogel lens in the other eye. After six months of daily wear another fifty measurements of refractive state were taken for each subject. Results:  Although  there  is  no  statisti-cal  support  for  the  findings  of  this  study, comet stereo-pairs are used to show the chang-es in refractive state for each subject. Four of  the  six  subjects  showed  an  increase  in myopia in the eye wearing the silicone lens. Discussion:  The  increase  in  myopia in eyes wearing a silicone hydrogel lens is contrary  to  the  findings  of  other  studies.

  8. Incidence and epidemiologic associations of corneal infiltrates with silicone hydrogel contact lenses.

    Science.gov (United States)

    Szczotka-Flynn, Loretta; Chalmers, Robin

    2013-01-01

    Contact lens-associated corneal infiltrative events (CIEs) are presumed sterile events that have complicated contact lens wear for more than 30 years. There is consistent evidence that silicone hydrogel soft contact lenses increase CIE risk by twofold compared with low Dk hydrogel materials. The incidence of CIEs during silicone hydrogel extended wear ranges from 2% to 6% for symptomatic events and from 6% to 25% when asymptomatic events are included. For daily wear, with silicone hydrogels, the incidence of CIEs ranges from 2% to 3% for symptomatic events and from 7% to 20% when asymptomatic events are included. Despite the increased rate of CIEs with silicone hydrogels, the benefits of these lenses largely outweigh this risk for many patients. Most risk factors for CIEs observed with silicone hydrogels are consistent with CIE risk factors reported earlier with hydrogel lenses, such as bacterial bioburden on lens surfaces, and young age among others. Limiting the transfer of bacterial bioburden from the skin to lenses, lens cases and eventually to the eye is an obvious step forward for the prevention of CIEs across all lens types.

  9. Atropine and Roscovitine Release from Model Silicone Hydrogels.

    Science.gov (United States)

    Lasowski, Frances; Sheardown, Heather

    2016-04-01

    Drug delivery to the anterior eye has a low compliance and results in significant drug losses. In pediatric patients, eye diseases such as myopia and retinoblastoma can potentially be treated pharmacologically, but the risk associated with high drug concentrations coupled with the need for regular dosing limits their effectiveness. The current study examined the feasibility of atropine and roscovitine delivery from model silicone hydrogel materials which could potentially be used to treat myopia and retinoblastoma, respectively. Model silicone hydrogel materials that comprised TRIS and DMA were prepared with the drug incorporated during synthesis. Various materials properties, with and without incorporated drug, were investigated including water uptake, water contact angle, and light transmission. Drug release was evaluated under sink conditions into phosphate buffered saline. The results demonstrate that up to 2 wt% of the drugs can be incorporated into model silicone hydrogel materials without adversely affecting critical materials properties such as water uptake, light transmission, and surface hydrophilicity. Equilibrium water content ranged from 15 to 32% and transmission exceeded 89% for materials with at least 70% DMA. Extended release exceeding 14 days was possible with both drugs, with the total amount of drug released from the materials ranging from 16% to over 76%. Although a burst effect was noted, this was thought to be due to surface-bound drug, and therefore storage in an appropriate packaging solution could be used to overcome this if desired. Silicone hydrogel materials have the potential to deliver drugs for over 2 weeks without compromising lens properties. This could potentially overcome the need for regular drop instillation and allow for the maintenance of drug concentration in the tear film over the period of wear. This represents a potential option for treating a host of ophthalmic disorders in children including myopia and retinoblastoma.

  10. Proteins identified from care solution extractions of silicone hydrogels.

    Science.gov (United States)

    Emch, Andrew J; Nichols, Jason J

    2009-02-01

    The purpose of this study was to investigate the quantity and identify the proteins extracted from two different types of silicone hydrogel contact lenses by several multipurpose care solutions after 1 day of wear. Ten subjects were recruited to wear galyfilcon A lenses (Acuvue Advance, Vistakon) followed by lotrafilcon B lenses (O2 Optix, CIBA Vision) each for four consecutive days. Each day, subjects inserted a new pair of lenses for 8 h of wear after which both lenses were removed using forceps (lenses were not rubbed or rinsed after removal). Lenses were pooled in one of four commercially available care solutions for a 24-h soak followed by precipitation, resuspension in water, and quantification by Bradford assay and identification by mass spectrometry. Protein recovery from care solutions was as follows (quantities are in microg/lens): AQuify (galyfilcon A: 0.56, lotrafilcon B: 1.24), Complete MoisturePlus (galyfilcon A: 1.44, lotrafilcon B: 1.47), Opti-Free Express (galyfilcon A: 2.31, lotrafilcon B: 5.67), and ReNu MoistureLoc (galyfilcon A: 1.17, lotrafilcon B: 4.38). For each care solution, greater quantities of protein were removed from lotrafilcon B (3.19 +/- 2.19 microg/lens) than from galyfilcon A (1.37 +/- 0.72 microg/lens). Lactoferrin, lysozyme, and lipocalin were the most commonly identified, whereas various keratin compounds and other unique proteins were also detected. Opti-Free Express was consistently associated with the more efficient removal of proteins from these silicone hydrogels. More total protein was removed from lotrafilcon B than from galyfilcon A (approximately 2 x more protein) for all four care solutions, and 12 total unique protein species were recovered from galyfilcon A, whereas only 10 were recovered from lotrafilcon B. The higher quantities of protein extracted from lotrafilcon B may be due to stronger protein binding with this material and/or to differences in solution efficacy.

  11. Atropine and Roscovitine Release from Model Silicone Hydrogels

    National Research Council Canada - National Science Library

    Lasowski, Frances; Sheardown, Heather

    2016-01-01

    ... for regular dosing limits their effectiveness. The current study examined the feasibility of atropine and roscovitine delivery from model silicone hydrogel materials which could potentially be used to treat myopia and retinoblastoma, respectively...

  12. Research on the friction and wear mechanism of Poly(vinyl alcohol)/hydroxylapatite composite hydrogel

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    Poly(vinyl alcohol)/Hydroxylapatite(PVA/HA) composite hydrogel was prepared with poly(vinyl alcohol) and hydroxylapatite as raw materials, using the method of repeated freezing and thawing.The morphologies of PVA/HA composite hydrogel were observed by means of high-accuracy 3D profiler and scanning electron microscope(SEM).The compressive elastic modulus and the stress relaxation characteristics of PVA/HA composite hydrogel were measured using the flat-head cylinder indenter.The friction and wear tests between PVA/HA composite hydrogel and bovine knee articular cartilage were performed on the micro-tribometer.The worn morphologies of PVA/HA composite hydrogel were observed with environmental scanning electron microscope(ESEM).The results showed that PVA/HA composite hydrogel has the cross-link network microstructure which is similar to that of the natural bovine knee articular cartilages.With the increase of freezing-thawing cycles and the HA content, the degree of cross-link and the crystallization of PVA/HA composite hydrogel both increase, the elastic modulus increases evidently, the rate of stress relaxation is improved and the value of balance stress decreases.The friction coefficient decreases with the increase of the freezing-thawing cycles and the HA content.The more the freezing-thawing cycles are, the earlier the friction coefficient reaches the stable balance value.The friction deformation depth between PVA/HA composite hydrogel and bovine knee articular cartilage is inversely proportional to freezing-thawing cycles and the HA content.The main wear mechanisms of PVA/HA composite hydrogel are plastic flowing and adhesive flaking.The wear severity degree decreases with the increase of freezing-thawing cycles and the HA content.

  13. Research on the friction and wear mechanism of Poly(vinyl alcohol)/hydroxylapatite composite hydrogel

    Institute of Scientific and Technical Information of China (English)

    ZHANG DeKun; SHEN YanQiu; GE ShiRong

    2009-01-01

    Poly(vinyl alcohol)/Hydroxylapatite(PVA/HA)composite hydrogel was prepared with poly(vinyl alcohol)and hydroxylapatite as raw materials,using the method of repeated freezing and thawing.The morphologies of PVA/HA composite hydrogel were observed by means of high-accuracy 3D profiler and scanning electron microscope(SEM).The compressive elastic modulus and the stress relaxation characteristics of PVA/HA composite hydrogel were measured using the flat-head cylinder indenter.The friction and wear tests between PVA/HA composite hydrogel and bovine knee articular cartilage were performed on the micro-tribometer.The worn morphologies of PVA/HA composite hydrogel were observed with environmental scanning electron microscope(ESEM).The results showed that PVA/HA composite hydrogel has the cross-link network microstructure which is similar to that of the natural bovine knee articular cartilages.With the increase of freezing-thawing cycles and the HA content,the degree of cross-link and the crystallization of PVA/HA composite hydrogel both increase,the elastic modulus increases evidently,the rate of stress relaxation is improved and the value of balance stress decreases.The friction coefficient decreases with the increase of the freezing-thawing cycles and the HA content.The more the freezing-thawing cycles are,the earlier the friction coefficient reaches the stable balance value.The friction deformation depth between PVA/HA composite hydrogel and bovine knee articular cartilage is inversely proportional to freezing-thawing cycles and the HA content.The main wear mechanisms of PVA/HA composite hydrogel are plastic flowing and adhesive flaking.The wear severity degree decreases with the increase of freezing-thawing cycles and the HA content.

  14. Overnight corneal swelling with high and low powered silicone hydrogel lenses☆

    Science.gov (United States)

    Moezzi, Amir M.; Fonn, Desmond; Varikooty, Jalaiah; Simpson, Trefford L.

    2014-01-01

    Purpose To compare central corneal swelling after eight hours of sleep in eyes wearing four different silicone hydrogel lenses with three different powers. Methods Twenty-nine neophyte subjects wore lotrafilcon A (Dk, 140), balafilcon A (Dk, 91), galyfilcon A (Dk, 60) and senofilcon A (Dk, 103) lenses in powers −3.00, −10.00 and +6.00 D on separate nights, in random order, and on one eye only. The contra-lateral eye (no lens) served as the control. Central corneal thickness was measured using a digital optical pachometer before lens insertion and immediately after lens removal on waking. Results For the +6.00 D and −10.00 D, lotrafilcon A induced the least swelling and galyfilcon A the most. The +6.00 D power, averaged across lens materials, induced significantly greater central swelling than the −10.00 and −3.00 D (Re-ANOVA, p < 0.001), (7.7 ± 2.9% vs. 6.8 ± 2.8% and 6.5 ± 2.5% respectively) but there was no difference between −10.00 and −3.00 D. Averaged for power, lotrafilcon A induced the least (6.2 ± 2.8%) and galyfilcon A the most (7.6 ± 3.0%) swelling at the center (Re-ANOVA, p < 0.001). Central corneal swelling with +6.00 D was significantly greater than −10.00 D lens power despite similar levels of average lens transmissibility of these two lens powers. Conclusions The differences in corneal swelling of the lens wearing eyes are consistent with the differences in oxygen transmission of the silicone hydrogel lenses. In silicone hydrogel lenses central corneal swelling is mainly driven by central lens oxygen transmissibility. PMID:25649637

  15. Size Dependence of Nanoscale Wear of Silicon Carbide.

    Science.gov (United States)

    Tangpatjaroen, Chaiyapat; Grierson, David; Shannon, Steve; Jakes, Joseph E; Szlufarska, Izabela

    2017-01-18

    Nanoscale, single-asperity wear of single-crystal silicon carbide (sc-SiC) and nanocrystalline silicon carbide (nc-SiC) is investigated using single-crystal diamond nanoindenter tips and nanocrystalline diamond atomic force microscopy (AFM) tips under dry conditions, and the wear behavior is compared to that of single-crystal silicon with both thin and thick native oxide layers. We discovered a transition in the relative wear resistance of the SiC samples compared to that of Si as a function of contact size. With larger nanoindenter tips (tip radius ≈ 370 nm), the wear resistances of both sc-SiC and nc-SiC are higher than that of Si. This result is expected from the Archard's equation because SiC is harder than Si. However, with the smaller AFM tips (tip radius ≈ 20 nm), the wear resistances of sc-SiC and nc-SiC are lower than that of Si, despite the fact that the contact pressures are comparable to those applied with the nanoindenter tips, and the plastic zones are well-developed in both sets of wear experiments. We attribute the decrease in the relative wear resistance of SiC compared to that of Si to a transition from a wear regime dominated by the materials' resistance to plastic deformation (i.e., hardness) to a regime dominated by the materials' resistance to interfacial shear. This conclusion is supported by our AFM studies of wearless friction, which reveal that the interfacial shear strength of SiC is higher than that of Si. The contributions of surface roughness and surface chemistry to differences in interfacial shear strength are also discussed.

  16. Measurement errors related to contact angle analysis of hydrogel and silicone hydrogel contact lenses.

    Science.gov (United States)

    Read, Michael L; Morgan, Philip B; Maldonado-Codina, Carole

    2009-11-01

    This work sought to undertake a comprehensive investigation of the measurement errors associated with contact angle assessment of curved hydrogel contact lens surfaces. The contact angle coefficient of repeatability (COR) associated with three measurement conditions (image analysis COR, intralens COR, and interlens COR) was determined by measuring the contact angles (using both sessile drop and captive bubble methods) for three silicone hydrogel lenses (senofilcon A, balafilcon A, lotrafilcon A) and one conventional hydrogel lens (etafilcon A). Image analysis COR values were about 2 degrees , whereas intralens COR values (95% confidence intervals) ranged from 4.0 degrees (3.3 degrees , 4.7 degrees ) (lotrafilcon A, captive bubble) to 10.2 degrees (8.4 degrees , 12.1 degrees ) (senofilcon A, sessile drop). Interlens COR values ranged from 4.5 degrees (3.7 degrees , 5.2 degrees ) (lotrafilcon A, captive bubble) to 16.5 degrees (13.6 degrees , 19.4 degrees ) (senofilcon A, sessile drop). Measurement error associated with image analysis was shown to be small as an absolute measure, although proportionally more significant for lenses with low contact angle. Sessile drop contact angles were typically less repeatable than captive bubble contact angles. For sessile drop measures, repeatability was poorer with the silicone hydrogel lenses when compared with the conventional hydrogel lens; this phenomenon was not observed for the captive bubble method, suggesting that methodological factors related to the sessile drop technique (such as surface dehydration and blotting) may play a role in the increased variability of contact angle measurements observed with silicone hydrogel contact lenses.

  17. Comparison of Development of Dry Eye in Conventional Hydrogel and Silicone Hydrogel Contact Lens Users

    Directory of Open Access Journals (Sweden)

    Rukiye Aydın

    2013-01-01

    Full Text Available Pur po se: To compare the level and severity of dry eye between conventional hydrogel and silicone hydrogel contact lens users by using dry eye questionnaires and clinical tests. Ma te ri al and Met hod: Forty-two contact lens users who attended the Cornea and Contact Lens Unit, Department of Ophthalmology at Dokuz Eylül University, were included in this study. The first group consisted of subjects who have used conventional hydrogel (CHL contact lens for minimum one year and maximum five years. The second group consisted of subjects who have used silicone hydrogel (SHL contact lens for minimum one year and maximum 5 years. Twenty healthy individuals with no history of contact lens use were included in the control group. OSDI (Ocular Surface Disease Index questionnaire was performed to all patients. The tear function was determined by Schirmer’s test and tear break-up time in all three groups. Re sults: There was no statistically significant OSDI score differences between CHL and SHL users. Nevertheless, it was noted that OSDI score in both groups was statistically higher than in the control group. There was no statistically significant difference in tear break-up time between CHL and SHL users. On the other hand, tear break-up time was significantly lower in both groups when compared to the control group. There was no significant difference among the groups for Schirmer scoring. Dis cus si on: The use of conventional hydrogel and silicone hydrogel lenses causes a decline in tear break-up time leading to dry eye symptoms. However, no differences were determined between CHL and SHL users with regard to the severity of dry eye symptoms. (Turk J Ophthalmol 2013; 43: 7-14

  18. Dynamic contact angle analysis of silicone hydrogel contact lenses.

    Science.gov (United States)

    Read, Michael Leonard; Morgan, Philip Bruce; Kelly, Jeremiah Michael; Maldonado-Codina, Carole

    2011-07-01

    Contact angle measurements are used to infer the clinical wetting characteristics of contact lenses. Such characterization has become more commonplace since the introduction of silicone hydrogel contact lens materials, which have been associated with reduced in vivo wetting due to the inclusion of siloxane-containing components. Using consistent methodology and a single investigator, advancing and receding contact angles were measured for 11 commercially available silicone hydrogel contact lens types with a dynamic captive bubble technique employing customized, fully automated image analysis. Advancing contact angles were found to range between 20° and 72° with the lenses falling into six statistically discrete groupings. Receding contact angles fell within a narrower range, between 17° and 22°, with the lenses segregated into three groups. The relationship between these laboratory measurements and the clinical performance of the lenses requires further investigation.

  19. Clinical evaluation of a new multi-purpose disinfecting solution in symptomatic wearers of silicone hydrogel contact lenses

    Directory of Open Access Journals (Sweden)

    Corbin GS

    2012-07-01

    Full Text Available Glenn S Corbin,1 David L Kading,2 Sean M Powell,3 Brian D Rosenblatt,4 Glenda B Secor,5 Cecile A Maissa,6 Renee J Garofalo71Wyomissing Optometric Center, Wyomissing, PA, USA; 2Specialty Eyecare Group, Kirkland, WA, USA; 320/20 Eye Care LLC, Lenexa, KS, USA; 4Rosenblatt Family Eye Care Associates, Raritan, NJ, USA; 5Huntington Beach, CA, USA; 6OTG Research and Consultancy, London, UK; 7Alcon Research Ltd, Fort Worth, TX, USABackground: The purpose of this study was to evaluate the safety and efficacy of a new multi-purpose disinfecting solution containing a diblock copolymer, poly(oxyethylene-poly(oxybutylene, designed to improve the wetting properties of silicone hydrogel lenses in patients with symptoms of discomfort.Methods: This 30-day, randomized, concurrently controlled, double-masked, multi-site study involved 589 subjects at 42 investigational sites in the US. Existing symptomatic lens wearers were randomly assigned to either regimen 1 (OPTI-FREE® PureMoist®, Alcon Laboratories Inc, a newly developed formulation containing the diblock copolymer, or regimen 2 (renu® fresh™ multi-purpose solution Bausch + Lomb, Inc. On days 0, 14 and 30, subjects assessed acceptability and comfort using seven Likert-type questions, rated the intensity of ocular symptoms (comfort, dryness, irritation, scratchiness, burning, stinging on a visual analog scale (0–100, as well as reported lens wearing time, comfortable lens wearing time, and rewetting drop frequency. The investigators assessed slit-lamp findings (including circumlimbal conjunctival lissamine green staining and corneal fluorescein staining, on-eye lens surface wettability and deposits, visual acuity, and adverse events.Results: Differences favoring regimen 1 were noted on Day 30 for the primary Likert statement “I can comfortably wear my lenses” (P = 0.047 and for comfortable lens wear time (P = 0.041. Symptoms of ocular scratchiness, ocular burning, and ocular stinging were all rated

  20. Glaucoma therapy by extended release of timolol from nanoparticle loaded silicone-hydrogel contact lenses.

    Science.gov (United States)

    Jung, Hyun Jung; Abou-Jaoude, Michelle; Carbia, Blanca E; Plummer, Caryn; Chauhan, Anuj

    2013-01-10

    Glaucoma is the second major cause of blindness in the world after cataract. Glaucoma management through eye drops that reduce the intraocular pressure (IOP) has major deficiencies including low patient compliance and low bioavailability. Extended wear contact lenses that deliver glaucoma drugs for extended periods could increase patient compliance, while also increasing the bioavailability. To develop extended wear contact lenses that can also provide extended glaucoma therapy, we disperse nanoparticles of PGT (propoxylated glyceryl triacylate) that contain a glaucoma drug timolol. The particles can also be loaded into prefabricated lenses by soaking the lenses in a solution of particles in ethanol. The particle loaded gels can release timolol in phosphate buffered saline (PBS) for about a month at room temperature. The most likely rate controlling mechanism is hydrolysis of the ester bond that links timolol to the PGT matrix, but other mechanisms such as water and drug diffusion, drug dissolution, drug-polymer chain cleavage, time-dependent drug permeability within the polymeric matrix, etc. may also be important. Nanoparticle incorporation in the silicone hydrogels results in reduction in ion and oxygen permeabilities, and an increase in modulus, and the impact on each of these properties is proportional to the particle loading. A gel with 5% particle loading can deliver timolol at therapeutic doses for about a month at room temperature, with a minimal impact on critical lens properties. Preliminary animal studies in Beagle dogs conducted with lenses in which particles are loaded by soaking the lenses in ethanol show a reduction in IOP.

  1. Soft hydrogels interpenetrating silicone – a polymer network for drug releasing medical devices

    DEFF Research Database (Denmark)

    Steffensen, Søren Langer; Merete H., Vestergaard,; Møller, Eva H;

    2016-01-01

    such a sophisticated material by forming an interpenetrating polymer network (IPN) material through modification of silicone elastomers with a poly(2-hydroxyethyl methacrylate) (PHEMA)-based hydrogel. IPN materials with a PHEMA content in the range of 13%–38% (w/w) were synthesized by using carbon dioxide......-based solvent mixtures under high pressure. These IPNs were characterized with regard to microstructure as well as ability of the hydrogel to form a surface-connected hydrophilic carrier network inside the silicone. A critical limit for hydrogel connectivity was found both via simulation and by visualization...

  2. Silicon-based plant defences, tooth wear and voles.

    Science.gov (United States)

    Calandra, Ivan; Zub, Karol; Szafrańska, Paulina A; Zalewski, Andrzej; Merceron, Gildas

    2016-02-01

    Plant-herbivore interactions are hypothesized to drive vole population cycles through the grazing-induced production of phytoliths in leaves. Phytoliths act as mechanical defences because they deter herbivory and lower growth rates in mammals. However, how phytoliths impair herbivore performance is still unknown. Here, we tested whether the amount of phytoliths changes tooth wear patterns. If confirmed, abrasion from phytoliths could play a role in population crashes. We applied dental microwear texture analysis (DMTA) to laboratory and wild voles. Lab voles were fed two pelleted diets with differing amounts of silicon, which produced similar dental textures. This was most probably due to the loss of food mechanical properties through pelletization and/or the small difference in silicon concentration between diets. Wild voles were trapped in Poland during spring and summer, and every year across a population cycle. In spring, voles feed on silica-rich monocotyledons, while in the summer they also include silica-depleted dicotyledons. This was reflected in the results; the amount of silica therefore leaves a traceable record in the dental microwear texture of voles. Furthermore, voles from different phases of population cycles have different microwear textures. We tentatively propose that these differences result from grazing-induced phytolith concentrations. We hypothesize that the high amount of phytoliths in response to intense grazing in peak years may result in malocclusion and other dental abnormalities, which would explain how these silicon-based plant defences help provoke population crashes. DMTA could then be used to reconstruct vole population dynamics using teeth from pellets or palaeontological material. © 2016. Published by The Company of Biologists Ltd.

  3. Abrasive wear behavior of heat-treated ABC-silicon carbide

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Xiao Feng; Lee, Gun Y.; Chen, Da; Ritchie, Robert O.; De Jonghe, Lutgard C.

    2002-06-17

    Hot-pressed silicon carbide, containing aluminum, boron, and carbon additives (ABC-SiC), was subjected to three-body and two-body wear testing using diamond abrasives over a range of sizes. In general, the wear resistance of ABC-SiC, with suitable heat treatment, was superior to that of commercial SiC.

  4. Friction and wear behavior of single-crystal silicon carbide in sliding contact with various metals

    Science.gov (United States)

    Miyoshi, K.; Buckley, D. H.

    1978-01-01

    Sliding friction experiments were conducted with single-crystal silicon carbide in contact with various metals. Results indicate the coefficient of friction is related to the relative chemical activity of the metals. The more active the metal, the higher the coefficient of friction. All the metals examined transferred to silicon carbide. The chemical activity of the metal and its shear modulus may play important roles in metal-transfer, the form of the wear debris and the surface roughness of the metal wear scar. The more active the metal, and the less resistance to shear, the greater the transfer to silicon carbide and the rougher the wear scar on the surface of the metal. Hexagon-shaped cracking and fracturing formed by cleavage of both prismatic and basal planes is observed on the silicon carbide surface.

  5. Visualization of a hyaluronan network on the surface of silicone-hydrogel materials

    Directory of Open Access Journals (Sweden)

    Wygladacz KA

    2016-07-01

    Full Text Available Katarzyna A Wygladacz, Daniel J Hook Vision Care, Bausch & Lomb Incorporated, Rochester, NY, USA Abstract: Biotrue multipurpose solution (MPS is a bioinspired disinfecting and conditioning solution that includes hyaluronic acid (HA as a natural wetting agent. Previous studies demonstrated that HA sorbed from Biotrue MPS on both conventional and silicone hydrogel (SiHy contact lens materials; an in vitro simulated-wear test validated the presence of HA on the lens surfaces for as long as 20 hours. In this study, the morphology and distribution of HA sorbed from both Biotrue and pure HA solution on SiHy contact lens surfaces was examined. Atomic force microscopy imaging was used to illustrate the topography of fresh SiHy contact lens materials before and after incubation with 0.1% (w/v HA solution. The distribution, as well as fine details of the HA network, were resolved by first staining HA with Gram’s safranin, then imaging with confocal laser-scanning microscopy and differential interference-contrast microscopy. In this approach, SiHy materials take up the dye (safranin nonspecifically, such that the resultant safranin–HA complex appears dim against the fluorescent lens background. Balafilcon A was chosen as the representative of glassy SiHy lenses that require postpolymerization plasma treatment to increase wettability. Senofilcon A and samfilcon A were chosen as representatives of SiHy materials fabricated with an internal wetting agent. A confluent and dim HA–safranin network was observed adhered to balafilcon A, senofilcon A, and samfilcon A lens surfaces incubated with either 0.1% (w/v HA solution or Biotrue MPS. Therefore, the conditioning function provided by Biotrue MPS may be in part explained by the presence of the HA humectant layer that readily sorbs on the various types of SiHy contact lens materials. Keywords: contact lens, hyaluronan, MPS, AFM, CLSM, DIC microscopy

  6. Ciprofloxacin interaction with silicon-based and conventional hydrogel contact lenses.

    Science.gov (United States)

    Karlgard, C C S; Jones, L W; Moresoli, C

    2003-04-01

    Hydrogel contact lenses can be used as bandage lenses to protect the corneal surface after injury. The use of novel silicon-based hydrogel lens materials as bandage lenses has not gained widespread acceptance. As a first step toward advocating their usefulness as bandage lenses, their interaction with ocular pharmaceuticals must be understood because topical agents are often administered in conjunction with bandage lenses. The in vitro uptake and release of ciprofloxacin from silicone-based hydrogel (SH) and conventional pHEMA-based (CH) hydrogel contact lenses was examined by spectrophotometric evaluation of the drug concentration in saline solution. The hydrogel contact lenses tested showed similar drug uptake (average 1800 microg/lens) but different levels of drug release. Multiphoton laser microscopy indicated that ciprofloxacin was distributed throughout the lens thickness, with higher levels of drug at the surface owing to drug precipitation. The drug adsorption onto the lenses was partially reversible. The SH lenses released a lower amount of drug than CH lenses (72 vs. 168 microg/lens). Ionic lenses released less drug than non-ionic lenses (127 vs. 151 microg/lens). The differences in ciprofloxacin uptake and release between SH and CH materials may not be clinically significant because the amount of drug released from all lenses would be above the MIC(90) of ciprofloxacin for common ocular pathogens. These results indicate that material properties have a significant impact on drug-lens interactions.

  7. The Long-Term Effects of Silicone Hydrogel Contact Lenses on the Ocular Surface and Tear Function Tests

    Directory of Open Access Journals (Sweden)

    Yelda Yıldız Taşcı

    2014-05-01

    Full Text Available Objectives: To evaluate the effects of three different silicone hydrogel contact lenses, i.e. Balafilcon A (Pure Vision, Bausch & Lomb, Senofilcon A (Acuvue Oasys, Johnson & Johnson, and Confilcon A (Biofinity, CooperVision, on ocular surface after one, three, and sıx months of wear. Materials and Methods: Silicone hydrogel contact lenses (SHCL were fitted to 58 patients (Balafilcon A to 40 eyes: Group 1, Senofilcon A to 42 eyes: Group 2, and Confilcon A to 34 eyes: Group 3 who have not used any contact lenses before. All groups were graded according to the Cornea and Contact Lens Research Unit’s grading score, and were performed ocular surface disease index scoring (OSDI, tear break-up time (BUT, and Schirmer 1 test. Results: The mean age was 22.45±5.96, 20.76±3.70, 21.00±3.84 years in Groups 1,2, and 3, respectively (p>0.05. While the increase in papillary hypertrophy as well as palpebral and bulbar hyperemia at 1st month in Group 1 and at 6th month at Group 2 were significant, there were no change in Group 3 with the use of SHCL (p0.05. In Group 3, the Schirmer test was lower than in Groups 1 and 2, which was statistically significant (p=0.048, p=0.003. Conclusion: Factors like lens material, modulus, the presence of an internal wetting agent, and water content play an important role in the effects of SHCL on the ocular surface. In this study, it is demonstrated that SHCL does not cause clinically significant dry eye. (Turk J Ophthalmol 2014; 44: 201-6

  8. Comparative study of two silicone hydrogel contact lenses used as bandage contact lenses after photorefractive keratectomy

    Directory of Open Access Journals (Sweden)

    Hasan Razmjoo

    2012-01-01

    Conclusion: Silicon hydrogel BCLs are safe and effective for corneal reepithelialization and have great therapeutic outcome on visual outcomes after PRK. But, senofilcon A had better effect on postoperative pain and discomfort which made it superior than lotrafilcon A. However for more conclusive results, it is recommended to study larger sample size with evaluation the possible factors responsible for the obtained findings regarding postoperative pain and discomfort.

  9. Study of abrasive wear rate of silicon using n-alcohols

    Science.gov (United States)

    Danyluk, S.

    1982-01-01

    The work carried out at the University of Illinois at Chicago for the Flat-Plate Solar Array Project under contract No. 956053 is summarized. The abrasion wear rate of silicon in a number of fluid environments and the parameters that influence the surface mechanical properties of silicon were determined. Three tests were carried out in this study: circular and linear multiple-scratch test, microhardness test and a three-point bend test. The pertinent parameters such as effect of surface orientation, dopant and fluid properties were sorted. A brief review and critique of previous work is presented.

  10. External ocular surface and lens microbiota in contact lens wearers with corneal infiltrates during extended wear of hydrogel lenses.

    Science.gov (United States)

    Willcox, Mark; Sharma, Savitri; Naduvilath, Thomas J; Sankaridurg, Padmaja R; Gopinathan, Usha; Holden, Brien A

    2011-03-01

    To determine whether carriage of microbes on the contact lens or ocular surfaces during extended wear (EW) with soft hydroxyethyl methacrylate (HEMA)-based contact lenses predisposes the wearer to adverse events. Participants (non-contact lens wearers) were enrolled in a clinical study involving wear of HEMA-based hydrogel lenses on a six night EW basis with weekly replacement. Type and number of bacteria colonizing the lower lid margins, upper bulbar conjunctiva, and contact lenses during EW after one night, 1 week, 1 month, and thereafter every 3 months for 3.5 years were determined. The association of bacteria with adverse responses was compared between carriers (defined as having significant microbes cultured from two or more samples with 1 year) and noncarriers, and the strength of the association was estimated using multivariate logistic regression. Carriers of gram-positive bacteria on lenses (particularly coagulase negative staphylococci or Corynebacterium spp.) were approximately three and eight times more likely to develop contact lens-induced peripheral ulcers (CLPUs) and asymptomatic infiltrates (AIs), respectively. Staphylococcus aureus was most frequently isolated from lenses during CLPU. Carriers of gram-negative bacteria on lenses were five times more likely to develop contact lens-induced acute red eye (CLARE). Haemophilus influenzae was isolated most frequently from lenses during CLARE and AI events. Bacterial carriage on contact lenses during EW predisposes the wearer to the development of corneal inflammatory events including CLARE, CLPU, and AI.

  11. Conjunctival Changes in Wearers of Frequent Replacement Hydrogel and Frequent Replacement Silicone Hydrogel Contact Lenses: Comparison Using Impression Cytology Technique

    Directory of Open Access Journals (Sweden)

    Rukiye Aydın FEBO

    2014-01-01

    Full Text Available Objectives: To compare the level of conjunctival changes using conjunctival impression cytology in wearers of frequent replacement hydrogel (FRHL and frequent replacement silicone hydrogel contact lens FRSHL. Materials and Methods: Forty-two contact lens users who were seen at the Cornea and Contact Lens Unit, Department of Ophthalmology, Dokuz Eylül University were evaluated in this study. The first group consisted of wearers of FRHL used for minimum one year and maximum five years. The second group consisted of wearers who used FRSHL for minimum one year and maximum 5 years. Twenty healthy individuals with no contact lens history were included in the control group. Conjunctival impression cytology was applied to all contact lens users and the control group in order to evaluate the conjunctival changes, and the results of impression cytology were graded by the Nelson’s method. Results: In the comparison of the groups according to impression cytology scoring, there was no difference between the users of FRHL and FRSHL. Similar amounts of squamous metaplasia and goblet cell loss were encountered in both groups. Nonetheless, impression cytology grading was significantly lower in the control group than in the other two groups. Conclusion: In conclusion, the use of FRHL and FRSHL for over a year causes some histological changes in the conjunctiva such as squamous metaplasia and goblet cell loss eventually leading to dry eye symptoms. However, no differences were determined between FRHL and FRSHL users with regard to severity of conjunctival changes. (Turk J Ophthalmol 2014; 44: 47-52

  12. Enzymatic quantification of cholesterol and cholesterol esters from silicone hydrogel contact lenses.

    Science.gov (United States)

    Pucker, Andrew D; Thangavelu, Mirunalni; Nichols, Jason J

    2010-06-01

    The purpose of this work was to develop an enzymatic method of quantification of cholesterol and cholesterol esters derived from contact lenses, both in vitro and ex vivo. Lotrafilcon B (O2 Optix; CIBA Vision, Inc., Duluth, GA) and galyfilcon A (Acuvue Advance; Vistakon, Inc., Jacksonville, FL) silicone hydrogel contact lenses were independently incubated in cholesterol oleate solutions varying in concentrations. After incubation, the lenses were removed and underwent two separate 2:1 chloroform-methanol extractions. After in vitro studies, 10 human subjects wore both lotrafilcon B and galyfilcon A contact lenses for 7 days. The lenses also underwent two separate 2:1 chloroform-methanol extractions. All in vitro and ex vivo samples were quantified with a cholesterol esterase enzymatic reaction. Calibration curves from quantifications of in vitro contact lens samples soaked in successively decreasing concentrations of cholesterol oleate yielded coefficients of determination (R(2)) of 0.99 (lotrafilcon B) and 0.97 (galyfilcon A). For in vitro contact lens samples, galyfilcon A was associated with an average cholesterol oleate extraction of 39.85 +/- 48.65 microg/lens, whereas lotrafilcon B was associated with 5.86 +/- 3.36 microg/lens (P = 0.05) across both extractions and all incubation concentrations. For ex vivo contact lens samples, there was significantly more cholesterol and cholesterol esters deposited on galyfilcon A (5.77 +/- 1.87 microg/lens) than on lotrafilcon B (2.03 +/- 1.62 microg/lens; P = 0.0005). This is an efficient and simple method of quantifying total cholesterol extracted from silicone hydrogel contact lenses and, potentially, the meibum and/or tear film. Certain silicone hydrogel materials demonstrate more affinity for cholesterol and its esters than do others.

  13. Highly wear-resistant ultra-thin per-fluorinated organic monolayers on silicon(1 1 1) surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Pujari, Sidharam P. [Laboratory of Organic Chemistry, Wageningen University, Dreijenplein 8, 6703 HB Wageningen (Netherlands); Zuilhof, Han, E-mail: Han.Zuilhof@wur.nl [Laboratory of Organic Chemistry, Wageningen University, Dreijenplein 8, 6703 HB Wageningen (Netherlands); Department of Chemical and Materials Engineering, King Abdulaziz University, Jeddah (Saudi Arabia)

    2013-12-15

    This study reports on fluorine-containing alkyne-derived monolayers onto Si(1 1 1) substrates to obtain densely packed, highly wear-resistant surfaces. The nano-wear properties were measured using atomic force microscopy (AFM). The presence of the fluorinated monolayers was found to enhance the wear properties of the silicon surfaces, with a decrease of the depth of wear scratches of up to 120 times as compared to the unmodified surface. Ultimately, the scratch depth was only 6 nm for a heptadecafluoro-alkyl based monolayer for scratching normal forces as high as 38 μN.

  14. In vitro and in vivo evaluation of ketotifen fumarate-loaded silicone hydrogel contact lenses for ocular drug delivery.

    Science.gov (United States)

    Xu, Jinku; Li, Xinsong; Sun, Fuqian

    2011-02-01

    The purpose of this work was to evaluate the usefulness of silicone hydrogel contact lenses loaded with ketotifen fumarate for ocular drug delivery. First, silicone contact lenses were prepared by photopolymerization of bitelechelic methacrylated polydimethylsiloxanes macromonomer, 3-methacryloxypropyltris(trimethylsiloxy)silane, and N,N-dimethylacrylamide using ethylene glycol dimethacrylate as a cross-linker and Darocur 1173 as an initiator followed by surface plasma treatment. Then, the silicone hydrogel matrices of the contact lenses were characterized by equilibrium swelling ratio (ESR), tensile tests, ion permeability, and surface contact angle. Finally, the contact lenses were loaded with ketotifen fumarate by pre-soaking in drug solution to evaluate drug loading capacity, in vitro and in vivo release behavior of the silicone contact lenses. The results showed that ESR and ion permeability increase, and the surface contact angle and tensile strength decreased with the increase of DMA component in the silicone hydrogel. The drug loading and in vitro releases were dependent on the hydrogel composition of hydrophilic/hydrophobic phase of the contact lenses. In rabbit eyes, the pre-soaked contact lenses sustained ketotifen fumarate release for more than 24 h, which leads to a more stable drug concentration and a longer mean retention time in tear fluid than that of eye drops of 0.05%.

  15. Micropatterning hydroxy-PAAm hydrogels and Sylgard 184 silicone elastomers with tunable elastic moduli.

    Science.gov (United States)

    Versaevel, Marie; Grevesse, Thomas; Riaz, Maryam; Lantoine, Joséphine; Gabriele, Sylvain

    2014-01-01

    This protocol describes a simple method to deposit protein micropatterns over a wide range of culture substrate stiffness (three orders of magnitude) by using two complementary polymeric substrates. In the first part, we introduce a novel polyacrylamide hydrogel, called hydroxy-polyacrylamide (PAAm), that permits to surmount the intrinsically nonadhesive properties of polyacrylamide with minimal requirements in cost or expertize. We present a protocol for tuning easily the rigidity of "soft" hydroxy-PAAm hydrogels between ~0.5 and 50 kPa and a micropatterning method to locally deposit protein micropatterns on these hydrogels. In a second part, we describe a protocol for tuning the rigidity of "stiff" silicone elastomers between ~100 and 1000 kPa and printing efficiently proteins from the extracellular matrix. Finally, we investigate the effect of the matrix rigidity on the nucleus of primary endothelial cells by tuning the rigidity of both polymeric substrates. We envision that the complementarity of these two polymeric substrates, combined with an efficient microprinting technique, can be further developed in the future as a powerful mechanobiology platform to investigate in vitro the effect of mechanotransduction cues on cellular functions, gene expression, and stem cell differentiation.

  16. Sterilization of silicone-based hydrogels for biomedical application using ozone gas: Comparison with conventional techniques.

    Science.gov (United States)

    Galante, Raquel; Ghisleni, Daniela; Paradiso, Patrizia; Alves, Vitor D; Pinto, Terezinha J A; Colaço, Rogério; Serro, Ana Paula

    2017-09-01

    Sterilization of hydrogels is challenging due to their often reported sensitivity to conventional methods involving heat or radiation. Although aseptic manufacturing is a possibility, terminal sterilization is safer in biological terms, leading to a higher overall efficiency, and thus should be used whenever it is possible. The main goal of this work was to study the applicability of an innovative ozone gas terminal sterilization method for silicone-based hydrogels and compare its efficacy and effects with those of traditional sterilization methods: steam heat and gamma irradiation. Ozone gas sterilization is a method with potential interest since it is reported as a low cost green method, does not leave toxic residues and can be applied to thermosensitive materials. A hydrogel intended for ophthalmological applications, based on tris(trimethylsiloxy)silyl] propyl methacrylate, was prepared and extensively characterized before and after the sterilization procedures. Alterations regarding transparency, swelling, wettability, ionic permeability, friction coefficient, mechanical properties, topography and morphology and chemical composition were monitored. Efficacy of the ozonation was accessed by performing controlled contaminations and sterility tests. In vitro cytotoxicity testes were also performed. The results show that ozonation may be applied to sterilize the studied material. A treatment with 8 pulses allowed sterilizing the material with bioburdens≤10(3)CFU/mL, preserving all the studied properties within the required known values for contact lenses materials. However, a higher exposure (10 pulses) led to some degradation of the material and induced mild cytotoxicity. Steam heat sterilization led to an increase of swelling capacity and a decrease of the water contact angle. Regarding gamma irradiation, the increase of irradiation dose led to an increase of the friction coefficient. The higher dose (25kGy) originated surface degradation and affected the

  17. Biomaterial characteristics and application of silicone rubber and PVA hydrogels mimicked in organ groups for prostate brachytherapy.

    Science.gov (United States)

    Li, Pan; Jiang, Shan; Yu, Yan; Yang, Jun; Yang, Zhiyong

    2015-09-01

    It is definite that transparent material with similar structural characteristics and mechanical properties to human tissue is favorable for experimental study of prostate brachytherapy. In this paper, a kind of transparent polyvinyl alcohol (PVA) hydrogel and silicone rubber are developed as suitable substitutions for human soft tissue. Segmentation and 3D reconstruction of medical image are performed to manufacture the mould of organ groups through rapid prototyping technology. Micro-structure observation, force test and CCD deformation test have been conducted to investigate the structure and mechanical properties of PVA hydrogel used in organ group mockup. Scanning electron microscope (SEM) image comparison results show that PVA hydrogel consisting of 3 g PVA, 17 g de-ionized water, 80 g dimethyl-sulfoxide (DMSO), 4 g NaCl, 1.5 g NaOH, 3 g epichlorohydrin (ECH) and 7 freeze/thaw cycles reveals similar micro-structure to human prostate tissue. Through the insertion force comparison between organ group mockup and clinical prostate brachytherapy, PVA hydrogel and silicone rubber are found to have the same mechanical properties as prostate tissue and muscle. CCD deformation test results show that insertion force suffers a sharp decrease and a relaxation of tissue deformation appears when needle punctures the capsule of prostate model. The results exhibit that organ group mockup consisting of PVA hydrogel, silicone rubber, membrane and agarose satisfies the needs of prostate brachytherapy simulation in general and can be used to mimic the soft tissues in pelvic structure.

  18. Ethylene oxide-block-butylene oxide copolymer uptake by silicone hydrogel contact lens materials

    Energy Technology Data Exchange (ETDEWEB)

    Huo, Yuchen [Department of Materials Science and Engineering, University of Florida, Rhines Hall 100, Gainesville, FL 32611 (United States); Ketelson, Howard [Alcon Inc., Research and Development, Vision Care, 6201 South Freeway, Fort Worth, TX 76134 (United States); Perry, Scott S., E-mail: ssp@mse.ufl.edu [Department of Materials Science and Engineering, University of Florida, Rhines Hall 100, Gainesville, FL 32611 (United States)

    2013-05-15

    Four major types of silicone hydrogel contact lens material have been investigated following treatments in aqueous solutions containing poly(ethylene oxide) and poly(butylenes oxide) block copolymer (EO–BO). The extent of lens surface modification by EO–BO and the degree of bulk uptake were studied using X-ray photoelectron spectroscopy (XPS) and ultra-performance liquid chromatography (UPLC), respectively. The experimental results suggest that different interaction models exist for the lenses, highlighting the influence of both surface and bulk composition, which greatly differs between the lenses examined. Specifically, lenses with hydrophilic surface treatments, i.e., PureVision{sup ®} (balafilcon A) and O{sub 2}OPTIX (lotrafilcon B), demonstrated strong evidence of preferential surface adsorption within the near-surface region. In comparison, surface adsorption on ACUVUE{sup ®} Oasys{sup ®} (senofilcon A) and Biofinity{sup ®} (comfilcon A) was limited. As for bulk absorption, the amount of EO–BO uptake was the greatest for balafilcon A and comfilcon A, and least for lotrafilcon B. These findings confirm the presence of molecular concentration gradients within the silicone hydrogel lenses following exposure to EO–BO solutions, with the nature of such concentration gradients found to be lens-specific. Together, the results suggest opportunities for compositional modifications of lenses for improved performance via solution treatments containing surface-active agents.

  19. Enhanced plasmid loss in bacterial populations exposed to the antimicrobial compound irgasan delivered from interpenetrating polymer network silicone hydrogels

    DEFF Research Database (Denmark)

    Riber, Leise; Burmølle, Mette; Alm, Martin;

    2016-01-01

    into liquid growth medium from irgasan-impregnated Interpenetrating Polymer Network (IPN) silicone hydrogel objects, a novel technology developed as drug-delivery platform. IPN-mediated irgasan-release was indirectly monitored as the extent of plasmid loss from bacterial cells during a 24-hour period...

  20. Contact lens wear is intrinsically inflammatory.

    Science.gov (United States)

    Efron, Nathan

    2017-01-01

    Eye-care practitioners typically associate ocular inflammation during contact lens wear with serious complications such as microbial keratitis; however, more subtle mechanisms may be at play. This paper tests the notion that contact lens wear is intrinsically inflammatory by exploring whether uncomplicated contact lens wear meets the classical, clinical definition of inflammation - rubor (redness), calor (heat), tumor (swelling), dolor (pain) and functio laesa (loss of function) - as well as the contemporary, sub-clinical definition of inflammation (cellular and biochemical reactions). It is demonstrated that all of these clinical and sub-clinical criteria are met with hydrogel lens wear and most are met with silicone hydrogel lens wear, indicating that uncomplicated contact lens wear is intrinsically inflammatory. Consideration of both traditional and contemporary thinking about the role of inflammation in the human body leads to the perhaps surprising conclusion that the chronic, low grade, sub-clinical inflammatory status of the anterior eye during contact lens wear, which may be termed 'para-inflammation', is a positive, protective phenomenon, whereby up-regulation of the immune system, in a non-damaging way, maintains the eye in a state of 'heightened alert', ready to ward off any extrinsic noxious challenge. Characterisation of this inflammatory status may lead to the development of lens engineering or pharmacological strategies to modulate contact lens-induced inflammation, so as to render lens wear more safe and comfortable. © 2016 Optometry Australia.

  1. Effect of scandium addition on the microstructure, mechanical and wear properties of the spray formed hypereutectic aluminum–silicon alloys

    Energy Technology Data Exchange (ETDEWEB)

    Raghukiran, Nadimpalli; Kumar, Ravi, E-mail: nvrk@iitm.ac.in

    2015-08-12

    Hypereutectic Al–x%Si–0.8Sc alloys (x=13, 16, 19 and 22 wt%) were produced by spray forming. The microstructures of all the alloys exhibited very fine silicon phase with average size of about 5–10 µm irrespective of the silicon content of the alloy. Transmission electron microscopy revealed the presence of a nano-scale scandium rich phase, identified as AlSi{sub 2}Sc{sub 2} (V-phase) uniformly distributed in the alloy. The presence of V-phase resulted in higher matrix hardness (1.34 GPa) in contrast to 1.04 GPa observed in the case of binary Al–Si alloys by nanoindentation. Isothermal heat treatment at 375 °C revealed insignificant coarsening of silicon phase in both binary and ternary alloys. The Al–x%Si–0.8Sc alloys exhibited higher flow stress and tensile strength in contrast to their binary alloy counterparts which was attributed to the bi-modal size distribution of the strengthening phases in the form of nano-scale V-phase and sub-micron to 10 µm size silicon particles. The pin-on-disk wear tests exhibited appreciable improvement in the wear performance of the relatively low-silicon content ternary alloys over their binary counterparts while the high-silicon content binary and ternary alloys exhibited no much difference in the wear performance.

  2. Silicone hydrogel contact lens surface analysis by atomic force microscopy: shape parameters

    Science.gov (United States)

    Giraldez, M. J.; Garcia-Resua, C.; Lira, M.; Sánchez-Sellero, C.; Yebra-Pimentel, E.

    2011-05-01

    Purpose: Average roughness (Ra) is generally used to quantify roughness; however it makes no distinction between spikes and troughs. Shape parameters as kurtosis (Rku) and skewness (Rsk) serve to distinguish between two profiles with the same Ra. They have been reported in many biomedical fields, but they were no applied to contact lenses before. The aim of this study is to analyze surface properties of four silicone hydrogel contact lenses (CL) by Atomic Force Microscopy (AFM) evaluating Ra, Rku and Rsk. Methods: CL used in this study were disposable silicone hydrogel senofilcon A, comfilcon A, balafilcon A and lotrafilcon B. Unworn CL surfaces roughness and topography were measured by AFM (Veeco, multimode-nanoscope V) in tapping modeTM. Ra, Rku and Rsk for 25 and 196 μm2 areas were determined. Results: Surface topography and parameters showed different characteristics depending on the own nature of the contact lens (Ra/Rku/Rsk for 25 and 196 μm2 areas were: senofilcon A 3,33/3,74/0,74 and 3,76/18,16/1,75; comfilcon A: 1,56/31,09/2,93 and 2,76/45,82/3,60; balafilcon A: 2,01/33,62/-2,14 and 2,54/23,36/-1,96; lotrafilcon B: 26,97/4,11/-0,34 and 29,25/2,82/-0,23). In lotrafilcon B, with the highest Ra, Rku showed a lower degree of peakedness of its distribution. Negative Rsk value obtained for balafilcon A showed a clear predominance of valleys in this lens. Conclusions: Kku and Rsk are two statistical parameters useful to analyse CL surfaces, which complete information from Ra. Differences in values distribution and symmetry were observed between CL.

  3. Self-assembled thin film of imidazolium ionic liquid on a silicon surface: Low friction and remarkable wear-resistivity

    Energy Technology Data Exchange (ETDEWEB)

    Gusain, Rashi [CSIR-Indian Institute of Petroleum, Mohkampur, Dehardun 248005 (India); Academy of Scientific and Innovative Research, New Delhi 110025 (India); Kokufu, Sho [Department of Materials Science and Engineering, Kyoto University, Kyoto 606-8501 (Japan); Bakshi, Paramjeet S. [CSIR-Indian Institute of Petroleum, Mohkampur, Dehardun 248005 (India); Utsunomiya, Toru; Ichii, Takashi; Sugimura, Hiroyuki [Department of Materials Science and Engineering, Kyoto University, Kyoto 606-8501 (Japan); Khatri, Om P., E-mail: opkhatri@iip.res.in [CSIR-Indian Institute of Petroleum, Mohkampur, Dehardun 248005 (India); Academy of Scientific and Innovative Research, New Delhi 110025 (India)

    2016-02-28

    Graphical abstract: - Highlights: • Ionic liquid thin film is deposited on a silicon surface via covalent interaction. • Chemical and morphological features of ionic liquid thin film are probed by XPS and AFM. • Ionic liquid thin film exhibited low and steady friction along with remarkable wear-resistivity. - Abstract: Imidazolium-hexafluorophosphate (ImPF{sub 6}) ionic liquid thin film is prepared on a silicon surface using 3-chloropropyltrimethoxysilane as a bifunctional chemical linker. XPS result revealed the covalent grafting of ImPF{sub 6} thin film on a silicon surface. The atomic force microscopic images demonstrated that the ImPF{sub 6} thin film is composed of nanoscopic pads/clusters with height of 3–7 nm. Microtribological properties in terms of coefficient of friction and wear-resistivity are probed at the mean Hertzian contact pressure of 0.35–0.6 GPa under the rotational sliding contact. The ImPF{sub 6} thin film exhibited low and steady coefficient of friction (μ = 0.11) along with remarkable wear-resistivity to protect the underlying silicon substrate. The low shear strength of ImPF{sub 6} thin film, the covalent interaction between ImPF{sub 6} ionic liquid thin film and underlying silicon substrate, and its regular grafting collectively reduced the friction and improved the anti-wear property. The covalently grafted ionic liquid thin film further shows immense potential to expand the durability and lifetime of M/NEMS based devices with significant reduction of the friction.

  4. Evaluation of corneal optical properties in subjects wearing hydrogel etafilcon A contact lenses and the effect of administering mannitol-enriched sodium hyaluronate ophthalmic solution

    Directory of Open Access Journals (Sweden)

    Lombardo M

    2014-11-01

    Full Text Available Marco Lombardo,1,2 Marianna Rosati,1 Marco Pileri,3 Domenico Schiano-Lomoriello,1 Sebastiano Serrao11Fondazione G.B. Bietti IRCCS, 2Vision Engineering Italy Srl, 3Azienda Ospedaliera San Giovanni-Addolorata, Rome, ItalyBackground: The purpose of this study was to evaluate the effect of daily administration of mannitol-enriched sodium hyaluronate ophthalmic solution on the corneal optical properties of subjects wearing low Dk hydrogel (etafilcon A contact lenses (CLs.Methods: Forty-five subjects wearing etafilcon A CLs daily for more than 6 months were recruited into this pilot study. Fifteen of the subjects administered a 10% mannitol-enriched 0.05% sodium hyaluronate solution (study group once daily and 30 subjects did not administer any ophthalmic solution (control group. The subjects were examined at baseline and one month after recruitment. Changes in central corneal thickness (CCT and corneal light backscatter were evaluated by Scheimpflug imaging (Pentacam HR. Changes in corneal total high-order aberration, corneal spherical aberration, coma, and trefoil were evaluated using the OPD scan II.Results: At one month, corneal light backscatter decreased significantly in the study group (≤18.30 arbitrary units; P<0.05 and this was highly correlated with a decrease in CCT (R=0.81; P=0.04. The decrease in corneal total high-order aberration, spherical aberration, and coma was significantly higher in the study group than in the control group (P<0.05. No changes in corneal light backscatter or CCT were found in the control group during follow-up.Conclusion: Once-daily administration of a mannitol-enriched lubricant ophthalmic solution was effective for improving the corneal optical quality and reducing corneal swelling in subjects wearing low Dk hydrogel (etafilcon A CLs during one month follow-up.Keywords: corneal optical quality, corneal high-order aberrations, Scheimpflug imaging, corneal backscattering, contact lens, hypertonic lubricant

  5. Wear Characteristics of Hybrid Composites Based on Za27 Alloy Reinforced With Silicon Carbide and Graphite Particles

    Directory of Open Access Journals (Sweden)

    S. Mitrović

    2014-06-01

    Full Text Available The paper presents the wear characteristics of a hybrid composite based on zinc-aluminium ZA27 alloy, reinforced with silicon-carbide and graphite particles. The tested sample contains 5 vol.% of SiC and 3 vol.% Gr particles. Compocasting technique has been used to prepare the samples. The experiments were performed on a “block-on-disc” tribometer under conditions of dry sliding. The wear volumes of the alloy and the composite were determined by varying the normal loads and sliding speeds. The paper contains the procedure for preparation of sample composites and microstructure of the composite material and the base ZA27 alloy. The wear surface of the composite material was examined using the scanning electronic microscope (SEM and energy dispersive spectrometry (EDS. Conclusions were obtained based on the observed impact of the sliding speed, normal load and sliding distance on tribological behaviour of the observed composite.

  6. Impact of Cosmetics on the Surface Properties of Silicone Hydrogel Contact Lenses.

    Science.gov (United States)

    Srinivasan, Sruthi; Otchere, Heinz; Yu, Mili; Yang, Jeffery; Luensmann, Doerte; Jones, Lyndon

    2015-07-01

    This study evaluated the impact of various cosmetics on the surface properties of silicone hydrogel (SiHy) contact lens materials. In this in vitro experiment, 7 SiHy contact lens materials were coated with 1 of 9 cosmetics, including common hand creams (3), eye makeup removers (3), and mascaras (3). Dark-field microscopy images were taken to determine pixel brightness (PB) after cosmetic exposure, which describes the visible surface deposition (n=6 for each lens type), with a higher PB indicating increased deposition. The sessile drop technique was used to determine the advancing contact angle (CA). Measurements were repeated for both methods after a single peroxide-based cleaning cycle. Pixel brightness was significantly higher for mascara-coated lenses compared with the other cosmetic products (P0.05). Hand creams and makeup remover had minimal impact on PB. Changes in CA measurements after cosmetic application were highly lens dependent. Hand creams caused primarily a decrease in CA for 5 of the 7 lens types, whereas 1 of the waterproof mascaras caused a significant increase of 30 to 50° for 3 lens types. Some mascara-lens combinations resulted in increased CA and PB, which could have an impact on in vivo lens performance. Nonwaterproof mascara was mostly removed after a cleaning cycle. Further research is needed to understand the clinical implications for SiHy lens wearers using cosmetics.

  7. Impact of Cosmetics on the Physical Dimension and Optical Performance of Silicone Hydrogel Contact Lenses.

    Science.gov (United States)

    Luensmann, Doerte; Yu, Mili; Yang, Jeffery; Srinivasan, Sruthi; Jones, Lyndon

    2015-07-01

    To evaluate the impact of cosmetics on silicone hydrogel (SiHy) contact lens shape, lens power, and optical performance. In this in vitro experiment, 7 SiHy materials were coated with 9 marketed brands of cosmetics, including hand creams (HCs) (3), eye makeup removers (MRs) (3), and mascaras (3). Diameter, sagittal depth, and base curve were determined using the Chiltern (Optimec Limited), whereas lens power and optical performance were assessed using the Contest Plus (Rotlex). Six replicates were used for each lens and cosmetic combination. Measurements were repeated after a cleaning cycle using a one-step hydrogen peroxide solution. Makeup removers had the greatest impact on diameter, sagittal depth, and base curve, resulting in changes of up to 0.5, 0.15, and 0.77 mm, respectively. The HCs and mascaras had little impact on these parameters; however, differences were observed between lens types. Optical performance was reduced with all mascaras, and a decrease of greater than 2 units on a 0 to 10 scale (10=uniform power distribution) was seen for 5 lens types exposed to waterproof mascara (Pcosmetics (± 0.25 diopter; P>0.05). Lens cleaning resulted in some recovery of the lens parameters, and efficiency varied between cosmetics. Some eye MRs and waterproof mascaras changed the shape and optical performance of some SiHy lenses. Further research is needed to understand the clinical implications for SiHy lens wearers using cosmetics.

  8. Evaluation of safety and efficacy of a new multipurpose disinfecting solution on silicone hydrogel contact lenses.

    Science.gov (United States)

    Pinto-Fraga, José; Blázquez Arauzo, Francisco; Urbano Rodríguez, Rubén; González-García, María J

    2015-01-01

    To evaluate the safety and efficacy of a new multipurpose disinfecting solution (MPDS) with a formulation that includes aloe vera on its composition. This is a prospective, randomized, double-masked clinical trial with a crossover design that included seven examinations. Two different MPDSs, Avizor Alvera® (study solution) and All Clean Soft® (control solution), each were used for 1 month. Comfilcon A silicone hydrogel contact lenses were used during the trial. The main outcome variables were corneal staining and deposits on the surfaces of the contact lenses. Other parameters including ocular surface response, contact lens wettability, user satisfaction, and adverse events, were analyzed according to the International Organization for Standardization (ISO) 11980:2010 guidance for clinical investigation. Twenty subjects (10 women, 10 men) (mean age, 27.7±5.6 years; range, 20-41) were included. No differences between both MPDSs were found in the percentage of subjects with corneal staining >0 at day 30 (study: 35%, control: 50%; p=0.46); neither in the percentage of subjects with deposits on the surface of the contact lens >0 at day 30 (study: 26.32%, control: 52.63%; p=0.18). The study MPDS received higher rates in comfort (study: 8.14±1.09, control: 7.94±0.92; p=0.56) and satisfaction at day 30 (study: 8.63±0.91, control: 8.29±0.80; p=0.19), however the scores were not significantly different with the control MPDS. The clinical trial showed that the study MPDS is safe, efficient, and has acceptable physiologic tolerance, according to the ISO 11980:2010 guidance for clinical investigation. Copyright © 2014 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  9. Effects of Antifungal Soaked Silicone Hydrogel Contact Lenses on Candida albicans in an Agar Eye Model.

    Science.gov (United States)

    Phan, Chau-Minh; Bajgrowicz, Magdalena; McCanna, David J; Subbaraman, Lakshman N; Jones, Lyndon

    2016-09-01

    To evaluate the effects of two commercial silicone hydrogel contact lenses (CLs) soaked with natamycin (NA) or fluconazole (FL) on the growth of Candida albicans in an in vitro eye model. Three-D printed molds were used as a cast for making eye-shaped models comprising potato dextrose agar. Senofilcon A (SA) and lotrafilcon B (LB) CLs were incubated with either 2 mL of NA or FL at a concentration of 1 mg/mL for 24 hr. To simulate a fungal infection, the eye models were coated with C. albicans. The drug-soaked lenses were placed on top of the eye models. Seven experimental conditions were examined: (1) NA-SA, (2) NA-LB, (3) FL-SA, (4) FL-LB, (5) SA, (6) LB, and (7) control-no lens. At specified time points (t=1, 8, 16, 24, 48 hr), the agar eyes from each experimental condition were removed from the incubator and photographed. The yeast cells from the 24 and 48 hr time point were also analyzed using light microscopy. At 24 and 48 hr, there was considerable growth observed for all conditions except for the NA-SA and NA-LB conditions. When observed under the microscope at 24 and 48 hr, the morphology of the yeast cells in the FL-SA and SA condition were similar to that of the control (oval shaped). There was limited hyphae growth observed for LB and significant visible hyphae growth for the NA-LB group. For NA-SA, NA-LB, and FL-LB groups, the cells were significantly smaller compared with the control. For NA-SA and NA-LB, there was limited growth of C. albicans observed on the eye models even after 48 hr. Under the microscope, the cell morphology differ noticeably between each testing condition, and is dependent on drug-lens combinations.

  10. Role of Silicon Dioxide Filler on Mechanical and Dry Sliding Wear Behaviour of Glass-Epoxy Composites

    Directory of Open Access Journals (Sweden)

    Naveed Anjum

    2013-01-01

    Full Text Available The mechanical properties and dry sliding wear behaviour of glass fabric reinforced epoxy (G-E composite with varying weight percentage of silicon dioxide (SiO2 filler have been studied in the present work. The influence of sliding distance, velocity, and applied normal load on dry sliding wear behaviour has been considered using Taguchi's L9 orthogonal array. Addition of SiO2 increased the density, hardness, flexural, and impact strengths of G-E composite. Results of dry sliding wear tests showed increasing wear volume with increase in sliding distance, load, and sliding velocity for G-E and SiO2 filled G-E composites. Taguchi's results indicate that the sliding distance played a significant role followed by applied load, sliding velocity, and SiO2 loading. Scanning electron micrographs of the worn surfaces of composite samples at different test parameters show smooth surface, microploughing, and fine grooves under low load and velocity. However, severe damage of matrix with debonding and fiber breakage was seen at high load and velocity especially in unfilled G-E composite.

  11. The influence of the surface properties of silicon-fluorine hydrogel on protein adsorption.

    Science.gov (United States)

    Xie, Haijiao; Zhao, Zhengbai; An, Shuangshuang; Jiang, Yong

    2015-12-01

    A range of fluorinated hydrogels were synthesized using the copolymerization of 1, 1, 1, 3, 3, 3-hexafluoroisopropyl methacrylate (HFMA) or 1H, 1H, 7H-dodecafluoroheptyl methacrylate (DFMA) with hydrophilic monomers. Bovine serum albumin (BSA) and Lysozyme (LZM) were chosen as model proteins to investigate the performance of protein adsorption on the surface of these fluorinated hydrogels. It was found that the performance of the fluorinated hydrogels toward protein adsorption was different for different proteins; simultaneously, the amount of protein adsorption was related to but not linear with the fluorine content on the hydrogel surface. With increasing HFMA content, the mass of BSA adsorption increased in the first stage and then decreased, meanwhile the mass of LZM adsorption exhibited an upward trend in general. In addition, the amount of protein adsorption was also related to the type and length of the fluorinated groups. The hydrogels made from DFMA behaved better than HFMA hydrogels in terms of reducing protein adsorption. This study might provide further reference in choosing fluorine monomer to prepare protein-repelling hydrogels.

  12. Sliding Wear Behavior of Plasma Sprayed Zirconia Coating on Cast Aluminum against Silicon Carbide Ceramic

    Institute of Scientific and Technical Information of China (English)

    Thuong-Hien LE; Young-Hun CHAE; Seock-Sam KIM

    2005-01-01

    The sliding wear behaviors of ZrO2-22 wt pct MgO (MZ) and ZrO2-8 wt pct Y2O3 (YZ) coatings deposited on a cast aluminum alloy with bond layer (NiCrCoAlY) by plasma spray were investigated under dry test conditions at room temperature. Under all load conditions, the wear mechanisms of the MZ and YZ coatings were almost the same.The material transfer and pullout were involved in the wear process of the studied coatings under the test conditions.The wear rate of the MZ coating was less than that of the YZ coating. While increasing the normal load, the wear rates of the MZ and YZ coatings increased. SEM was used to examine the worn surfaces and to elucidate likely wear mechanisms. Energy dispersive X-ray spectroscopy (EDX) analysis of the worn surfaces indicated that material transfer occurred in the direction from the SiC ball to the disk. Fracture toughness had a significant influence on the wear performance of the coatings. It was suggested that the material transfer played an important role in the wear behavior.

  13. In vitro water wettability of silicone hydrogel contact lenses determined using the sessile drop and captive bubble techniques.

    Science.gov (United States)

    Maldonado-Codina, Carole; Morgan, Philip B

    2007-11-01

    This study investigated the water contact angles of five commercially available silicone hydrogel contact lenses (Acuvue Advance, Acuvue Oasys, Focus Night & Day, O2 Optix, and PureVision) using sessile drop and captive bubble techniques. The only lens type that showed a significant difference in water contact angle when measured by sessile drop direct from the blister compared with after 48 h of soaking/washing in saline was the Acuvue Advance lens (from 66 degrees to 96 degrees, respectively) (p=0.0002), presumably because of surface active agents within the blister solution. The water contact angle data split the lenses into two distinct groups (psessile drop measures and relatively low captive bubble values (thereby displaying significant hysteresis) whereas the Focus Night & Day and O2 Optix lenses showed relatively low sessile drop measures and relatively high captive bubble values (with little hysteresis). Contact angle analysis of hydrogel lens surfaces is highly methodologically dependent and may be able to predict the clinical performance of contact lenses in vivo.

  14. Slurry wear characteristics of zinc-based alloys: Effects of sand content of slurry, silicon addition to alloy system and traversal distance

    Institute of Scientific and Technical Information of China (English)

    B.K. PRASAD; O.P. MODI

    2009-01-01

    This investigation deals with the observations pertaining to the effects of specimen and slurry compositions as well as traversal distance on the slurry wear response of a zinc-based alloy. The composition of the alloy was altered by adding 4% silicon to it. The slurry composition was varied through changing the concentration of the sand particles in the range of 0-60% that were suspended in the (liquid) electrolyte. The electrolyte contained 4 g sodium chloride and 5 mL concentrated sulphuric acid dissolved in 10 L of water. The slurry wear tests were conducted at a speed of 7.02 m/s over the traversal distance range of 15-500 km. The wear rate increased initially with traversal distance, attained a maximum and decreased thereafter irrespective of the specimen and test environment. However, the wear rate peaks were less prominent in the liquid plus sand environments than the liquid-only medium. Further, the wear rate peak in the liquid-only medium appeared at a shorter traversal distance than the one in the sand containing slurries. Addition of sand particles to the electrolyte reduced the wear rate of the samples to 5%-15% depending on the sand concentration of the slurry. Moreover, intermediate (40%) sand content led to a maximum wear rate when compared with in the liquid plus sand media. However, this maximum was still less than in the liquid-only medium. The silicon containing alloy suffered from higher wear rates than the silicon free alloy samples when tested in the liquid-only medium. On the contrary, the trend reversed in liquid plus 20% and 40% sand environments whereas a mixed response was noted in the slurry containing 60% sand. In the latter case, the presence of silicon proved deleterious initially while an opposite trend was observed at longer traversal distances. The wear response of the samples was discussed in terms of specific features of their microconstituents like silicon and the predominant material removal mechanism in a given set of

  15. Effect of ion nitriding on the abrasive wear resistance of ultrahigh-strength steels with different silicon contents

    Science.gov (United States)

    Riofano, R. M. Muñoz; Casteletti, L. C.; Nascente, P. A. P.

    2005-02-01

    This article studies the effect of silicon (Si) on ultrahigh-strength AISI 4340 steels in connection with the thermal treatment, as well as the influence of this element on nitriding and, consequently, abrasive wear. Four alloys with different Si contents were nitrided at 350 °C (4 and 8 h) and 500 and 550 °C (2 and 4 h) in a gas mixture of 80 vol.% H2 and 20 vol.% N2. The nitrided layers were characterized by microhardness and pin-on-disk tests, optical microscopy, scanning electron microscopy with energy-dispersive x-ray spectrometry, and x-ray diffraction (XRD). The increase in Si enhanced the tempering resistance of the steels and also improved considerably the hardness of the nitrided layers. The increase in Si produced thinner compound layers with better hardness quality and high abrasive wear resistance. XRD analysis detected a mixture of nitrides in the layers γ‧-Fe4N, ɛ-Fe2 3N, CrN, MoN, and Si3N4 with their proportions varying with the nitriding conditions.

  16. Comparative wear mapping techniques

    DEFF Research Database (Denmark)

    Alcock, J.; Sørensen, Ole Toft; Jensen, S.

    1996-01-01

    Pin-on-disc tests of tungsten carbide pins against silicon carbide discs were performed and wear rate, mechanism and friction maps constructed. Correlations were observed between the wear mode and the friction of the pin-disc interface, and between the qualitative incidence of disruptive wear...

  17. Synthesis of Silicon-Containing Chitosan Hydrogels in a Glycolic Acid Medium

    Directory of Open Access Journals (Sweden)

    A. B. Shipovskaya

    2016-01-01

    Full Text Available The present paper considers a “one-pot” green sol-gel synthesis of hybrid inorganic/organic hydrogels based on chitosan glycolate by using organically modified silica Si(OGly4·2GlyOH as a precursor to form a network of ≡Si–O–Si≡ bonds at 4, 20, and 37°C. The gelation time of the multicomponent chitosan-containing system was estimated as a function of the composition (the polymer template and precursor concentrations, introduction of a low-molecular-weight accelerator NaCl and gelation conditions (the pH and temperature of the sol-gel process. It has been shown that an increased polymeric salt concentration, the introduction of an accelerator, and increased pH and temperature accelerate the gel-forming process.

  18. Dross formation mechanism and development of wear resistant scraper in aluminum-silicon-zinc coating bath

    Science.gov (United States)

    Varadarajan, Ashok

    Steel sheet manufacturers across the globe, face a huge loss of production due to the molten metal corrosion of the pot hardware in continuous galvanizing lines. The development of steel sheet with corrosion resistant for more than 30 years using a high aluminum content zinc coating has made an impact in the construction industry. High aluminum content bath (55 wt%) causes severe corrosion of the pot hardware and causes huge repair and replacement cost with frequent stoppages. One of the main reasons for stoppages is the severe dross formation over the submerged hardware (sink roll), which results in poor coating layer over the steel sheet. Complete understanding of the mechanism of the dross formation over the submerged hardware has not yet been completely achieved. In order to establish the dross formation mechanism, an array of tests was performed. Initial inhibition of Al attack by the silicon rich layer and further formation of Fe2Al 5 layer hindering the diffusion of the Al into the substrate were observed. Also, the effect of the hydrodynamic motion of the bathe in the dross formation mechanism was established. A series of tests for efficient removal of the dross formed over the sink roll using high hardness, corrosion resistant materials were conducted at 600°C. After these tests, an efficient scraping process with a potential for energy and cost savings was developed with a better scraper material, resulting in a reduction of 75% in line stoppages.

  19. Effects of Silicone Hydrogel Contact Lens Application on Corneal High-order Aberration and Visual Guality in Patients with Corneal Opacities

    Directory of Open Access Journals (Sweden)

    Sevda Aydın Kurna

    2012-03-01

    Full Text Available Pur po se: Evaluation of the corneal high-order aberrations and visual quality changes after application of silicone hydrogel contact lenses in patients with corneal opacities due to various etiologies. Ma te ri al and Met hod: Fifteen eyes of 13 patients with corneal opacities were included in the study. During the ophthalmologic examination before and after contact lens application, visual acuity was measured with Snellen acuity chart and contrast sensitivity - with Bailey-Lowie Charts in letters. Aberrations were measured with corneal aberrometer (NIDEK Magellan Mapper under a naturally dilated pupil. Spherical aberration, coma, trefoil, irregular astigmatism and total high-order root mean square (RMS values were recorded. Measurements were repeated with balafilcon A lenses (PureVision 2 HD, B&L on all patients. Re sults: Patient age varied between 23 and 50 years. Two eyes had subepithelial infiltrates due to adenoviral keratitis, 1 had nebulae due to previous infections or trauma, and 2 had Salzmann’s nodular degeneration. We observed a mean increase of 1 line in visual acuity and 5 letters in contrast sensitivity with contact lenses versus glasses in the patients. Mean RMS values of spherical aberration, irregular astigmatism and total high-order aberrations decreased significantly with contact lenses. Dis cus si on: Silicone hydrogel soft contact lenses may improve visual quality by decreasing the corneal aberrations in patients with corneal opacities. (Turk J Ophthalmol 2012; 42: 97-102

  20. The friction and wear of metals and binary alloys in contact with an abrasive grit of single-crystal silicon carbide

    Science.gov (United States)

    Miyoshi, K.; Buckley, D. H.

    1979-01-01

    Sliding friction experiments were conducted with various metals and iron-base binary alloys (alloying elements Ti, Cr, Mn, Ni, Rh, and W) in contact with single-crystal silicon carbide riders. Results indicate that the coefficient of friction and groove height (corresponding to the wear volume) decrease linearly as the shear strength of the bulk metal increases. The coefficient of friction and groove height generally decrease with an increase in solute content of binary alloys. A separate correlation exists between the solute to iron atomic radius ratio and the decreasing rates of change of coefficient of friction and groove height with increasing solute content. These rates of change are minimum at a solute to iron radius ratio of unity. They increase as the atomic ratio increases or decreases linearly from unity. The correlations indicate that atomic size is an important parameter in controlling friction and wear of alloys.

  1. Corrosion and wear behaviour of Al–Mg–Si alloy matrix hybrid composites reinforced with rice husk ash and silicon carbide

    OpenAIRE

    Kenneth Kanayo Alaneme; Tolulope Moyosore Adewale; Peter Apata Olubambi

    2014-01-01

    The corrosion and wear behaviour of Al–Mg–Si alloy matrix hybrid composites developed with the use of rice husk ash (RHA) and silicon carbide (SiC) particulates as reinforcements were investigated. RHA and SiC mixed in weight ratios 0:1, 1:3, 1:1, 3:1, and 1:0 were utilized to prepare 5, 7.5 and 10 wt% of the reinforcing phase with Al Mg Si alloy as matrix using double stir casting process. Open circuit corrosion potential (OCP) and potentiodynamic polarization measurements were used to study...

  2. Equivalences between refractive index and equilibrium water content of conventional and silicone hydrogel soft contact lenses from automated and manual refractometry.

    Science.gov (United States)

    González-Méijome, José M; López-Alemany, Antonio; Lira, Madalena; Almeida, José B; Oliveira, M Elisabete C D Real; Parafita, Manuel A

    2007-01-01

    The purpose of the present study was to develop mathematical relationships that allow obtaining equilibrium water content and refractive index of conventional and silicone hydrogel soft contact lenses from refractive index measures obtained with automated refractometry or equilibrium water content measures derived from manual refractometry, respectively. Twelve HEMA-based hydrogels of different hydration and four siloxane-based polymers were assayed. A manual refractometer and a digital refractometer were used. Polynomial models obtained from the sucrose curves of equilibrium water content against refractive index and vice-versa were used either considering the whole range of sucrose concentrations (16-100% equilibrium water content) or a range confined to the equilibrium water content of current soft contact lenses (approximately 20-80% equilibrium water content). Values of equilibrium water content measured with the Atago N-2E and those derived from the refractive index measurement with CLR 12-70 by the applications of sucrose-based models displayed a strong linear correlation (r2 = 0.978). The same correlations were obtained when the models are applied to obtain refractive index values from the Atago N-2E and compared with those (values) given by the CLR 12-70 (r2 = 0.978). No significantly different results are obtained between models derived from the whole range of the sucrose solution or the model limited to the normal range of soft contact lens hydration. Present results will have implications for future experimental and clinical research regarding normal hydration and dehydration experiments with hydrogel polymers, and particularly in the field of contact lenses. 2006 Wiley Periodicals, Inc.

  3. Corrosion and wear behaviour of Al–Mg–Si alloy matrix hybrid composites reinforced with rice husk ash and silicon carbide

    Directory of Open Access Journals (Sweden)

    Kenneth Kanayo Alaneme

    2014-01-01

    Full Text Available The corrosion and wear behaviour of Al–Mg–Si alloy matrix hybrid composites developed with the use of rice husk ash (RHA and silicon carbide (SiC particulates as reinforcements were investigated. RHA and SiC mixed in weight ratios 0:1, 1:3, 1:1, 3:1, and 1:0 were utilized to prepare 5, 7.5 and 10 wt% of the reinforcing phase with Al Mg Si alloy as matrix using double stir casting process. Open circuit corrosion potential (OCP and potentiodynamic polarization measurements were used to study the corrosion behaviour while coefficient of friction was used to assess the wear behaviour of the composites. The corrosion and wear mechanisms were established with the aid of scanning electron microscopy. The results show that the effect of RHA/SiC weight ratio on the corrosion behaviour of the composites in 3.5% NaCl solution was not consistent for the different weight percent of reinforcement (5, 7.5, and 10 wt% used in developing the Al–Mg–Si based composites. It was evident that for most cases the use of hybrid reinforcement of RHA and SiC resulted in improved corrosion resistance of the composites in 3.5% NaCl solution. Preferential dissolution of the more anodic Al–Mg–Si alloy matrix around the Al–Mg–Si matrix/RHA/SiC particle interfaces was identified as the primary corrosion mechanism. The coefficient of friction and consequently the wear resistance of the hybrid composites were comparable to that of the Al–Mg–Si alloy matrix reinforced with only SiC.

  4. Release of Ciprofloxacin-HCl and Dexamethasone Phosphate by Hyaluronic Acid Containing Silicone Polymers

    National Research Council Canada - National Science Library

    Nguyen, Darrene; Hui, Alex; Weeks, Andrea; Heynen, Miriam; Joyce, Elizabeth; Sheardown, Heather; Jones, Lyndon

    2012-01-01

    ...) into conventional hydrogel and hydrogels containing silicone as models for contact lens materials on the uptake and release of the fluoroquinolone antibiotic ciprofloxacin and the anti-inflammatory...

  5. Influence of silicon content and heat treatment on wear resistance of white chromium cast irons under high speed solidification conditions; Influencia del contenido de silicio y el tratamiento termico en la resistencia al desgaste de fundiciones blancas al cromo en condiciones de rapida solidificacion

    Energy Technology Data Exchange (ETDEWEB)

    Goyo, L.; Varela, A.; Verhaege, M.; Garcia, A.; Mier, J.; Moors, M.

    2012-11-01

    The influence of silicon content and heat treatment on microstructure, abrasive and dry friction wear resistance of a 3 % C, 12 % Cr cast iron, under fast solidification conditions is studied. The fast solidification condition diminishes the carbide volume and the silicon content increases their dispersion and finesses. All matrixes obtained were perlitics, whit different finesses. No intermediate transformation products were noticed. Hardness had little variation. Austenization treatment show little effectivity, with tendency to increase wear in reference to as cast and maintenance treatments. Behavior under dry friction and abrasive wear were similar under test conditions applied whit more influence of carbide morphology in the abrasive wear conditions. (Author) 32 refs.

  6. Influence of high sintering pressure on the microhardness and wear resistance of diamond powder and silicon carbide-based composites

    Directory of Open Access Journals (Sweden)

    Oleksandr Sergueevitch Osipov

    2004-06-01

    Full Text Available The work reported on here involved the development of several samples of "diamond-SiC" composite produced under sintering pressures of up to 9.0 GPa at temperatures of up to 1973 7K. The average size of the diamond micropowder crystals used was 40/28 µm. The sintering process was carried out in a 2500-ton hydraulic press equipped with an anvil-type high-pressure device having a toroidal work surface and a central concavity diameter of 20 mm. The microhardness and wear resistance of the samples were found to be dependent on the sintering pressure. The experimental results indicated that the maximum microhardness and minimum wear resistance coefficients of each compact were attained when the pressure applied during sintering exceeded 6.5 GPa. Based on the established values of pressure, this study served to identify the types of devices applicable for the manufacture of composite material inserts for a variety of rock drilling applications.

  7. Influence of silicon and silicon alloy on properties and structure of wear-resistant reaction-bonded silicon carbide%硅及硅合金对反应烧结SiC耐磨材料性能与结构的影响

    Institute of Scientific and Technical Information of China (English)

    侯永改; 朱国朝; 李文凤; 邹文俊; 祝聿霏

    2011-01-01

    本文首先分析了熔渗材料硅及硅合金的润湿性、流动性、烧失率的变化.结果表明:熔渗材料硅在1 430℃,硅铁合金在1 470℃时润湿角小(分别为0°和6°)、流动性大(分别为267%和198%)、烧失率小(均小于15%).同时分析了反应烧结SiC耐磨材料性能,并采用扫描电子显微镜、X射线衍射仪、EDS分别对其显微结构、主晶相和成分进行了表征.结果表明:熔渗温度为1 470 ℃,保温3 h时,熔渗硅铁合金时,制得SiC耐磨材料体积密度大(2.94 g/cm3),硬度高(3 054.45 Hv)、耐磨性高;结构致密且有少量的晶须存在,有利于材料的增强增韧.%This research work studied the changes of wettability, fluidity, and burning loss rate of silicon and silicon alloy during infiltration sintering for siliscon carbide. The results showed that, silicon and ferro-silicon alloy has small wetting angle (0°and 6° ,respectively), high mobility (267% and 198% ,respectively), and low ignition loss( below 1 5 % in average) , when the infiltration sintering temperature of silicon attained 1 430 ℃, and that of ferro-silicon alloy was 1 470 ℃. Furthermore, the researchers analysed the performances of the reaction-bonded silicon carbide by means of scanning electronic microscope, X-ray diffraction and EDS to characterize its rnicrostructure, main phase and compositions. Research results showed that when the temperature for infiltration sintering was 1 470 ℃, and this temperature being hold for 3 h, the reactionbonded silicon carbide can get high density ( 2.94 g/cm3 ), high hardness (3 054.45 Hv), and high wear resistance (the wear is 0.015 g); also, the compact structure with a few whiskers is beneficial to enhance the wear resistance and toughness of silicon carbide.

  8. Hydrogel based occlusion systems

    OpenAIRE

    Stam, F.A.; Jackson, N.; Dubruel, P.; Adesanya, K.; Embrechts, A; Mendes, E.; Neves, H.P.; Herijgers, P; Verbrugghe, Y.; Shacham, Y.; Engel, L.; Krylov, V

    2013-01-01

    A hydrogel based occlusion system, a method for occluding vessels, appendages or aneurysms, and a method for hydrogel synthesis are disclosed. The hydrogel based occlusion system includes a hydrogel having a shrunken and a swollen state and a delivery tool configured to deliver the hydrogel to a target occlusion location. The hydrogel is configured to permanently occlude the target occlusion location in the swollen state. The hydrogel may be an electro-activated hydrogel (EAH) which could be ...

  9. Eye Wear

    Science.gov (United States)

    Eye wear protects or corrects your vision. Examples are Sunglasses Safety goggles Glasses (also called eyeglasses) Contact ... jobs and some sports carry a risk of eye injury. Thousands of children and adults get eye ...

  10. Hydrogel-based sensor for CO2 measurements

    NARCIS (Netherlands)

    Herber, S.; Olthuis, W.; Bergveld, P.; Berg, van den A.

    2004-01-01

    A hydrogel-based sensor is presented for CO2 measurements. The sensor consists of a pressure sensor and porous silicon cover. A pH-sensitive hydrogel is confined between the two parts. Furthermore the porous cover contains a bicarbonate solution and a gaspermeable membrane. CO2 reacts with the solut

  11. PRAGMATIC HYDROGELS

    Directory of Open Access Journals (Sweden)

    Patil S.A.

    2011-03-01

    Full Text Available Man has always been plagued with many ailments and diseases. The field of pharmaceutical science has today become more invaluable in helping to keep us healthy and prevent disease. The availability of large molecular weight protein and peptide-based drugs due to the recent advances has given us a new ways to treat a number of diseases. I wish to present new and promising techniques for the production of drug and protein delivery formulations that have been developed that is Hydrogel. These are presently under investigation as a delivery system for bioactive molecules as having similar physical properties as that of living tissue, which is due to their high water content, soft and rubbery consistency and low interfacial tension with water and biological fluids. Hydrogels are three-dimensional, hydrophilic, polymeric networks capable of imbibing large amounts of water or biological fluids. The networks are composed of homopolymers or copolymers, and are insoluble due to the presence of chemical crosslink (tie-points, junctions or physical crosslink, such as entanglements or crystallite. The latter provide the network structure and physical integrity. These hydrogels exhibit a thermodynamic compatibility with water which allows them to swell in aqueous media. The nature of the degradation product can be tailored by a rational and proper selection of building blocks. The soft and rubbery nature of hydrogels minimizes irritation to surrounding tissues. In general, hydrogels possess good biocompatibility and biodegradability.

  12. Hydrogel based occlusion systems

    NARCIS (Netherlands)

    Stam, F.A.; Jackson, N.; Dubruel, P.; Adesanya, K.; Embrechts, A.; Mendes, E.; Neves, H.P.; Herijgers, P.; Verbrugghe, Y.; Shacham, Y.; Engel, L.; Krylov, V.

    2013-01-01

    A hydrogel based occlusion system, a method for occluding vessels, appendages or aneurysms, and a method for hydrogel synthesis are disclosed. The hydrogel based occlusion system includes a hydrogel having a shrunken and a swollen state and a delivery tool configured to deliver the hydrogel to a tar

  13. Bioresponsive hydrogels

    Directory of Open Access Journals (Sweden)

    Rein V. Ulijn

    2007-04-01

    Full Text Available We highlight recent developments in hydrogel materials with biological responsiveness built in. These ‘smart’ biomaterials change properties in response to selective biological recognition events. When exposed to a biological target (nutrient, growth factor, receptor, antibody, enzyme, or whole cell, molecular recognition events trigger changes in molecular interactions that translate into macroscopic responses, such as swelling/collapse or solution-to-gel transitions. The hydrogel transitions may be used directly as optical readouts for biosensing, linked to the release of actives for drug delivery, or instigate biochemical signaling events that control or direct cellular behavior. Accordingly, bioresponsive hydrogels have gained significant interest for application in diagnostics, drug delivery, and tissue regeneration/wound healing.

  14. Smart hydrogel functional materials

    CERN Document Server

    Chu, Liang-Yin; Ju, Xiao-Jie

    2014-01-01

    This book systematically introduces smart hydrogel functional materials with the configurations ranging from hydrogels to microgels. It serves as an excellent reference for designing and fabricating artificial smart hydrogel functional materials.

  15. Wear behaviour of Al 261

    Directory of Open Access Journals (Sweden)

    N. Mathan Kumar

    2016-03-01

    Full Text Available Al 2618 matrix material was mixed with the Silicon Nitride (Si3N4, Aluminium Nitride (AlN and Zirconium Boride (ZrB2 reinforced particles. AMC was synthesized successfully by the stir casting method with the various X-wt.% of reinforcements (X = 0,2,4,6,8. Tribological behaviour was studied in this composite with various temperature conditions. The working conditions were Temperature (°C, Load (N, Velocity (m/s and Sliding Distances (m. Before wear testing the mechanical behaviour has been analysed. EDAX was confirmed by the matrix material composition. The Al 2618 alloy and the reinforcement mixers were confirmed by the X-ray Diffraction analysis. Wear rate (mm3/m, Wear resistance (m/mm3, Specific Wear rate (m/Nm and Co-efficient of friction (μ were analysed with various conditions. The worn surfaces were analysed before and after wear testing by Scanning Electron Microscope (SEM. Influence of process parameters and Percentage of contribution were analysed by Taguchi and Analysis of Variance (ANOVA methods. Genetic Algorithm (GA was adopted for optimizing the best and mean of the wear rate and to identify the exact influence of input parameters.

  16. Tooth wear

    Directory of Open Access Journals (Sweden)

    Tušek Ivan

    2014-01-01

    Full Text Available Tooth wear is the loss of dental hard tissue that was not caused by decay and represents a common clinical problem of modern man. In the etiology of dental hard tissue lesions there are three dominant mechanisms that may act synergistically or separately:friction (friction, which is caused by abrasion of exogenous, or attrition of endogenous origin, chemical dissolution of dental hard tissues caused by erosion, occlusal stress created by compression and flexion and tension that leads to tooth abfraction and microfracture. Wear of tooth surfaces due to the presence of microscopic imperfections of tooth surfaces is clinically manifested as sanding veneers. Tribology, as an interdisciplinary study of the mechanisms of friction, wear and lubrication at the ultrastructural level, has defined a universal model according to which the etiopathogenesis of tooth wear is caused by the following factors: health and diseases of the digestive tract, oral hygiene, eating habits, poor oral habits, bruxism, temporomandibular disorders and iatrogenic factors. Attrition and dental erosion are much more common in children with special needs (Down syndrome. Erosion of teeth usually results from diseases of the digestive tract that lead to gastroesophageal reflux (GER of gastric juice (HCl. There are two basic approaches to the assessment of the degree of wear and dental erosion. Depending on the type of wear (erosion, attrition, abfraction, the amount of calcium that was realised during the erosive attack could be determined qualitatively and quantitatively, or changes in optical properties and hardness of enamel could be recorded, too. Abrasion of teeth (abrasio dentium is the loss of dental hard tissue caused by friction between the teeth and exogenous foreign substance. It is most commonly provoked by prosthetic dentures and bad habits, while its effect depends on the size of abrasive particles and their amount, abrasive particle hardness and hardness of tooth

  17. Friction and wear of metals with a single-crystal abrasive grit of silicon carbide: Effect of shear strength of metal

    Science.gov (United States)

    Miyoshi, K.; Buckley, D. H.

    1978-01-01

    Sliding friction experiments were conducted with spherical, single-crystal silicon carbide riders in contact with various metals and with metal riders in contact with silicon carbide flats. Results indicate that: (1) the friction force in the plowing of metal and (2) the groove height (corresponding to the volume of the groove) are related to the shear strength of the metal. That is, they decrease linearly as the shear strength of the bulk metal increases. Grooves are formed in metals primarily from plastic deformation, with occasional metal removal. The relation between the groove width D and the load W can be expressed by W = kD, superscript n which satisfies Meyer's law.

  18. Double network hydrogel with high mechanical strength:Performance, progress and future perspective

    Institute of Scientific and Technical Information of China (English)

    CHEN YongMei; DONG Kun; LIU ZhenQi; XU Feng

    2012-01-01

    With high water content (~90 wt%) and significantly improved mechanical strength (~MPa),double network (DN) hydrogels have emerged as promising biomaterials with widespread applications in biomedicine.In recent years,DN hydrogels with extremely high mechanical strength have achieved great advance,and scientists have designed a series of natural and biomimetic DN hydrogels with novel functions including low friction,low wear,mechanical anisotropy and cell compatibility.These advances have also led to new design of biocompatible DN hydrogels for regeneration of tissues such as cartilage.In this paper,we reviewed the strategies of designing high-strength DN hydrogel and analyzed the factors that affect DN hydrogel properties.We also discussed the challenges and future development of the DN hydrogel in view of its potential as biomaterials for their biomedical applications.

  19. Hydraulic System Wear Debris Analysis.

    Science.gov (United States)

    1982-08-03

    drawn. Each one-=L sample was drawn with a clean plastic pipette of one-mL capacity. The samples were placed in clean Ferrogram preparation bottles ...and from cavities in a block which held linear seals into sampling bottles . Several photographs of this debris , which was deposited on Ferro- grams...silicon in the glass overshadowed the elements of the wear debris . To overcome this difficulty, the Ferrogram should be pre- pared on a carbon-filled

  20. Wear mechanism for spray deposited Al-Si/SiCp composites under dry sliding condition

    Institute of Scientific and Technical Information of China (English)

    滕杰; 李华培; 陈刚

    2015-01-01

    Al-Si/15%SiCp (volume fraction) composites with different silicon contents were fabricated by spray deposition technique, and typical microstructures of these composites were studied by optical microscopy (OM). Dry sliding wear tests were carried out using a block-on-ring wear machine to investigate the effect of applied load range of 10−220 N on the wear and friction behavior of these composites sliding against SAE 52100 grade bearing steel. Scanning electron microscopy (SEM) and energy-dispersive X-ray microanalysis (EDAX) were utilized to examine the morphologies of the worn surfaces in order to observe the wear characteristics and investigate the wear mechanism. The results show that the wear behavior of these composites is dependent on the silicon content in the matrix alloy and the applied load. Al-Si/15%SiCp composites with higher silicon content exhibit better wear resistance in the applied load range. Under lower loads, the major wear mechanisms are oxidation wear and abrasive wear for all tested composites. Under higher loads, severe adhesive wear becomes the main wear mechanisms for Al-7Si/15%SiCp and Al-13Si/15%SiCp composites, while Al-20Si/15%SiCp presents a compound wear mechanism, consisting of oxidation, abrasive wear and adhesion wear.

  1. Biphasic and boundary lubrication mechanisms in artificial hydrogel cartilage: A review.

    Science.gov (United States)

    Murakami, Teruo; Yarimitsu, Seido; Nakashima, Kazuhiro; Sakai, Nobuo; Yamaguchi, Tetsuo; Sawae, Yoshinori; Suzuki, Atsushi

    2015-12-01

    Various studies on the application of artificial hydrogel cartilage to cartilage substitutes and artificial joints have been conducted. It is expected in clinical application of artificial hydrogel cartilage that not only soft-elastohydrodynamic lubrication but biphasic, hydration, gel-film and boundary lubrication mechanisms will be effective to sustain extremely low friction and minimal wear in daily activities similar to healthy natural synovial joints with adaptive multimode lubrication. In this review article, the effectiveness of biphasic lubrication and boundary lubrication in hydrogels in thin film condition is focused in relation to the structures and properties of hydrogels. As examples, the tribological behaviors in three kinds of poly(vinyl alcohol) hydrogels with high water content are compared, and the importance of lubrication mechanism in biomimetic artificial hydrogel cartilage is discussed to extend the durability of cartilage substitute.

  2. Comparison of two hydrogel formulations for drug release in ophthalmic lenses.

    Science.gov (United States)

    Paradiso, P; Galante, R; Santos, L; Alves de Matos, A P; Colaço, R; Serro, A P; Saramago, B

    2014-08-01

    In the present work two types of polymers were investigated as drug releasing contact lens materials: a poly-hydroxyethylmethacrylate (pHEMA) based hydrogel and a silicone hydrogel. The silicone hydrogel resulted from the addition of TRIS, a hydrophobic monomer containing silicon (3-tris(trimethylsilyloxy)silylpropyl 2-methylprop-2-enoate), to pHEMA. Both hydrogels were loaded with an antibiotic (levofloxacin) and an antiseptic (chlorhexidine) by soaking in the drug solutions. The hydrogel properties were determined to be within the range demanded for lens materials. The release profiles of both drugs from the hydrogels were obtained and eventual drug/polymer interactions were assessed with the help of Raman spectra. A mathematical model, developed to mimic the eye conditions, was applied to the experimental results in order to predict the in vivo efficacy of the studied systems. The release profiles were compared with those resulting from the application of commercial eyedrops. The pHEMA based hydrogel demonstrated to be the best material to achieve a controlled release of levofloxacin. In the case of chlorhexidine, the silicone hydrogel seems to lead to better results. In both cases, our results suggest that these materials are adequate for the preparation of daily disposable therapeutic contact lenses.

  3. Oxygen and Contact Lens Wear%氧气与角膜接触镜配戴

    Institute of Scientific and Technical Information of China (English)

    王建华; Desmond Fonn; Renee Du Toit

    1999-01-01

    In this article we review the role of oxygen and contact lens wear related to the metabolic processes of the cornea.The critical oxygen requirement of the cornea for maintenance of its normal hydration level to ensure transparency is discussed,as well as the subsequent reversible and irreversible changes to the corneal layers if this requirement is not met.We review the concept of oxygen transmission and its application to rigid gas permeable and soft contact lens material.Corneal responses to induced hypoxia related to extended wear of contact lenses as well as other complications,such as infection,are discussed.In conclusion,we comment on the oxygen performance of a new generation of silicone hydrogel contact lens materials and the future of extended wear.%全球大约有八千万人(约占总人口的1.5%)在配戴角膜接触镜,镜片的透氧性及配戴角膜接触镜后角膜的获氧状态是保证配戴安全性和有效性的关键.角膜需要多种营养物质以保证其正常的代谢功能,氧气是其中是重要的部分,只有在充分氧供的状态下,角膜才能保持稳定的78%的水合状态,保证角膜透明性.为了进一步了解氧气与角膜接触镜配戴的关系,本文着重对角膜接触镜所致的角膜缺氧的主要表现及角膜接触镜的透氧性能及其表达指标作一综述.

  4. Fabricating customized hydrogel contact lens

    Science.gov (United States)

    Childs, Andre; Li, Hao; Lewittes, Daniella M.; Dong, Biqin; Liu, Wenzhong; Shu, Xiao; Sun, Cheng; Zhang, Hao F.

    2016-10-01

    Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young’s modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.

  5. Nanoscale wear as a stress-assisted chemical reaction.

    Science.gov (United States)

    Jacobs, Tevis D B; Carpick, Robert W

    2013-02-01

    Wear of sliding contacts leads to energy dissipation and device failure, resulting in massive economic and environmental costs. Typically, wear phenomena are described empirically, because physical and chemical interactions at sliding interfaces are not fully understood at any length scale. Fundamental insights from individual nanoscale contacts are crucial for understanding wear at larger length scales, and to enable reliable nanoscale devices, manufacturing and microscopy. Observable nanoscale wear mechanisms include fracture and plastic deformation, but recent experiments and models propose another mechanism: wear via atom-by-atom removal ('atomic attrition'), which can be modelled using stress-assisted chemical reaction kinetics. Experimental evidence for this has so far been inferential. Here, we quantitatively measure the wear of silicon--a material relevant to small-scale devices--using in situ transmission electron microscopy. We resolve worn volumes as small as 25 ± 5 nm(3), a factor of 10(3) lower than is achievable using alternative techniques. Wear of silicon against diamond is consistent with atomic attrition, and inconsistent with fracture or plastic deformation, as shown using direct imaging. The rate of atom removal depends exponentially on stress in the contact, as predicted by chemical rate kinetics. Measured activation parameters are consistent with an atom-by-atom process. These results, by direct observation, establish atomic attrition as the primary wear mechanism of silicon in vacuum at low loads.

  6. Wear behaviour of epoxy resin filled with hard powders

    Science.gov (United States)

    Formisano, A.; Boccarusso, L.; Minutolo, F. Capece; Carrino, L.; Durante, M.; Langella, A.

    2016-10-01

    The development of high performance materials based on epoxy resin finds a growing number of applications in which high wear resistance is required. One major drawback in many of these applications is the relatively poor wear resistance of the epoxy resin. Therefore, in order to investigate on the possibility of increasing wear resistance of thermoset polymers filled with hard powders, sliding tests are carried out by means of a pin on disc apparatus. In particular, composite resins, constituted by an epoxy resin filled with different contents and sizes of Silicon Carbide powder, are analyzed; the wear resistance, in terms of volume loss, is measured for different abrasive counterfaces and loads.

  7. Wearing gloves in the hospital

    Science.gov (United States)

    ... gloves; PPE - wearing gloves; Nosocomial infection - wearing gloves; Hospital acquired infection - wearing gloves ... Wearing gloves in the hospital helps prevent the spread of germs. This helps protect both patients and health care workers from infection.

  8. Wear Debris Analysis:Fundamental Principle of Wear-Graphy

    Institute of Scientific and Technical Information of China (English)

    陈铭; 王伟华; 殷勇辉; 王成焘

    2004-01-01

    A new wear-graphy technology was developed, which can simultaneously identify the shape and composition of wear debris, for both metals and non-metals.The fundamental principles of the wear-graphy system and its wear-gram system are discussed here.A method was developed to distribute wear debris on a slide uniformly to reduce overlapping of wear debris while smearing.The composition identification analyzes the wear debris using the scanning electron microscope (SEM) energy spectrum, infrared-thermal imaging and X-ray imaging technology.A wear debris analysis system based on database techniques is demonstrated, and a visible digitized wear-gram is acquired based on the information of wear debris with image collection and processing of the wear debris.The method gives the morphological characteristics of the wear debris, material composition identification of the wear debris, intelligent recognition of the wear debris, and storage and management of wear debris information.

  9. Study on Wear Reduction Mechanisms of Artificial Cartilage by Synergistic Protein Boundary Film Formation

    Science.gov (United States)

    Nakashima, Kazuhiro; Sawae, Yoshinori; Murakami, Teruo

    Poly(vinyl alcohol) (PVA) hydrogel is one of the anticipated materials for artificial cartilage. PVA hydrogel has high water content and a low elastic modulus similar to natural cartilage, but its major disadvantage is its lower strength. PVA hydrogel experienced rapid wear under severe conditions such as mixed or boundary lubrication. Therefore, the existence of a protective surface film with low friction becomes important to prevent surface failure. In this study, the reciprocating frictional tests for a sliding pair of PVA hydrogel and glass plate were carried out, and fluorescent observations were performed to identify the roles of adsorbed protein film. Albumin and γ-globulin, which are contained in natural synovial fluid, were used by mixing into the lubricant. It appears that groups of albumin molecules adsorb on the smooth γ-globulin adsorbed layer at content of 2.1wt% of proteins with an appropriate ratio. But in the case of a lubricant which has excessive protein at 2.8wt%, albumin and γ-globulin adsorbed separately. Considering the wear reduction at 2.1wt% content of protein, albumin and γ-globulin constituted synergistic adsorbed film for wear reduction. It is indicated that albumin constructs a low shear layer and γ-globulin forms a layer protecting PVA hydrogel from wear. It is considered that wear and friction of PVA hydrogel were reduced due to slip of the boundary of adsorbed albumin and γ-globulin layer. Content of protein and ratio of albumin to γ-globulin (AG ratio) are important to constitute the appropriate protein film.

  10. Protein surface patterning using nanoscale PEG hydrogels.

    Science.gov (United States)

    Hong, Ye; Krsko, Peter; Libera, Matthew

    2004-12-01

    We have used focused electron-beam cross-linking to create nanosized hydrogels and thus present a new method with which to bring the attractive biocompatibility associated with macroscopic hydrogels into the submicron length-scale regime. Using amine-terminated poly(ethylene glycol) thin films on silicon substrates, we generate nanohydrogels with lateral dimensions of order 200 nm which can swell by a factor of at least five, depending on the radiative dose. With the focused electron beam, high-density arrays of such nanohydrogels can be flexibly patterned onto silicon surfaces. Significantly, the amine groups remain functional after e-beam exposure, and we show that they can be used to covalently bind proteins and other molecules. We use bovine serum albumin to amplify the number of amine groups, and we further demonstrate that different proteins can be covalently bound to different hydrogel pads on the same substrate to create multifunctional surfaces useful in emerging bio/proteomic and sensor technologies.

  11. Hydrogels Constructed from Engineered Proteins.

    Science.gov (United States)

    Li, Hongbin; Kong, Na; Laver, Bryce; Liu, Junqiu

    2016-02-24

    Due to their various potential biomedical applications, hydrogels based on engineered proteins have attracted considerable interest. Benefitting from significant progress in recombinant DNA technology and protein engineering/design techniques, the field of protein hydrogels has made amazing progress. The latest progress of hydrogels constructed from engineered recombinant proteins are presented, mainly focused on biorecognition-driven physical hydrogels as well as chemically crosslinked hydrogels. The various bio-recognition based physical crosslinking strategies are discussed, as well as chemical crosslinking chemistries used to engineer protein hydrogels, and protein hydrogels' various biomedical applications. The future perspectives of this fast evolving field of biomaterials are also discussed.

  12. Mechanical and Wear Properties of SiC/Graphite Reinforced Al359 Alloy-based Metal Matrix Composite

    Directory of Open Access Journals (Sweden)

    Shubhranshu Bansal

    2015-07-01

    Full Text Available Al359 alloy was reinforced with Silicon Carbide and Silicon Carbide/Graphite particles using stir casting process. Thereafter their mechanical and wear properties were investigated. It was found that the hardness of the Al359-Silicon Carbide composite is better than Al359-Silicon Carbide-Graphite composite. The Silicon Carbide/Graphite reinforced composite exhibits a superior ultimate tensile strength against Silicon Carbide reinforced composite. The wear test was conducted at different loading, sliding velocities and sliding distances conditions. Results showed that the wear resistance of Al359 alloy increased with the reinforcement of Silicon Carbide/Graphite material for higher loading, sliding velocities and sliding distance conditions. SEM images of the worn surface of the pin were examined to study their wear mechanism.Defence Science Journal, Vol. 65, No. 4, July 2015, pp. 330-338, DOI: http://dx.doi.org/10.14429/dsj.65.8676

  13. Polymer wear evaluation

    DEFF Research Database (Denmark)

    Lagerbon, Mikkel; Sivebæk, Ion Marius

    2012-01-01

    the safety of the patients. Prediction of the wear of polymers is complicated by the low thermal conductivity of this kind of material. It implies that any acceleration of testing conditions by increased contact pressure and/or sliding velocity will make the polymer fail due to exaggerated heat buildup......Polymer wear plays an increasing role in manufacturing of machine parts for e.g. medical devices. Some of these have an expected lifetime of five to eight years during which very little wear of the components is acceptable. Too much wear compromises the dosage accuracy of the device and thereby....... This is not the kind of wear observed in medical devices. In the present work a method was developed capable of evaluating the wear progression in polymer-polymer contacts. The configuration of the setup is injection moulded specimens consisting of an upper part having a toroid shape and a lower flat part. The sliding...

  14. Polymer wear evaluation

    DEFF Research Database (Denmark)

    Lagerbon, Mikkel; Sivebæk, Ion Marius

    2012-01-01

    Polymer wear plays an increasing role in manufacturing of machine parts for e.g. medical devices. Some of these have an expected lifetime of five to eight years during which very little wear of the components is acceptable. Too much wear compromises the dosage accuracy of the device and thereby...... the safety of the patients. Prediction of the wear of polymers is complicated by the low thermal conductivity of this kind of material. It implies that any acceleration of testing conditions by increased contact pressure and/or sliding velocity will make the polymer fail due to exaggerated heat buildup....... This is not the kind of wear observed in medical devices. In the present work a method was developed capable of evaluating the wear progression in polymer-polymer contacts. The configuration of the setup is injection moulded specimens consisting of an upper part having a toroid shape and a lower flat part. The sliding...

  15. Effect of C-C b ond breakage on diamond to ol wear in nanometric cutting of silicon%单晶硅纳米切削中C-C键断裂对金刚石刀具磨损的影响∗

    Institute of Scientific and Technical Information of China (English)

    王治国; 张鹏; 陈家轩; 白清顺; 梁迎春

    2015-01-01

    It is well known that diamond is one of the most ideal cutting tool for materials, but the rapid tool wear can make surface integrity of the machined surface decline sharply during the nanometric cutting process for a single crystal silicon. Thus, a research on the wear mechanism of the diamond tool is of tremendous importance for selecting measures to reduce tool wear so as to extend service life of the tool. In this paper, the molecular dynamics simulation is applied to investigating the wear of the diamond tool during nanometric cutting for the single crystal silicon. Tersoff potential is used to describe the C—C and Si—Si interactions, and also the Morse potential for the C—Si interaction. The rake and flank faces are diamond (111) and (¯1¯12) planes respectively. A new method, by the name of 6-ring, is proposed to describe the bond change of carbon atoms. This new method can extract, all the worn carbon atoms in diamond tool, whose accuracy is higher than the conventional coordination number method. Moreover, the graphitized carbon atoms in the diamond tool also can be extracted by the combination of these two methods. Results show that during the cutting process, the C—C bond’s breaking in the surface layer of the diamond tool leads to the transformation of hybrid structure of the carbon atoms at both ends of the broken bond, from sp3 to sp2. Following to the bond breaking, the bond angle between the surface carbon atoms increases to 119.3◦ whose hybrid structure has changed, and the length between nearest neighboring atoms quickly decreases to 0.144 nm, indicating that the space structure formed by these carbon atoms has changed from 3D net structure of diamond to plane structure of graphite. Hence, the carbon atoms in the tool surface whose space structure has changed due to bond breaking should be defined as worn carbon atoms, but not only the carbon atoms whose hybrid structure has changed. The structure defects at both edges of the diamond

  16. Micro-scale wear characteristics of electroless Ni-P/SiC composite coating under two different sliding conditions

    OpenAIRE

    2014-01-01

    The electroless nickel composite (ENC) with various silicon carbide contents was deposited onto aluminium alloy (LM24) substrate. The wear behaviour and the microhardness of the composite coating samples were investigated and compared with particles free and aluminium substrate samples using micro-scale abrasion tester and microhardness tester respectively. The wear scar marks and wear volume were analysed by optical microscope. The wear tracks were further studied using scanning electron mic...

  17. Role of water in the tribochemical removal of bare silicon

    Science.gov (United States)

    Chen, Cheng; Xiao, Chen; Wang, Xiaodong; Zhang, Peng; Chen, Lei; Qi, Yaqiong; Qian, Linmao

    2016-12-01

    Nanowear tests of bare silicon against a SiO2 microsphere were conducted in air (relative humidity [RH] = 0%-89%) and water using an atomic force microscope. Experimental results revealed that the water played an important role in the tribochemical wear of the bare silicon. A hillock-like wear trace with a height of 0.7 nm was generated on the bare silicon surface in dry air. As the RH increased, the wear depth increased and reached the maximum level in water. Analysis of frictional dissipated energy suggested that the wear of the bare silicon was not dominated by mechanical interactions. High-resolution transmission electron microscopy detection demonstrated that the silicon atoms and crystal lattice underneath the worn area maintained integral perfectly and thus further confirmed the tribochemical wear mechanism of the bare silicon. Finally, the role of water in the tribochemical wear of the bare silicon may be explained by the following three aspects: the hydroxylation by hydroxyl ions auto-ionized in water, the hydrolytic reaction of water molecules, and the dissolution of the tribochemical product SiOmHn in liquid water. With increasing RH, a greater water amount would adsorb to the Si/SiO2 interface and induce a more serious tribochemical wear on the bare silicon surface. The results of this paper may provide further insight into the tribochemical removal mechanism of bare monocrystalline silicon and furnish the wider reaction cognition for chemical mechanical polishing.

  18. Analysis of Button Bit Wear and Performance of Down-The-Hole ...

    African Journals Online (AJOL)

    Michael O. Mensah

    2015-12-02

    Dec 2, 2015 ... revealed that wear of rock drill bit is influenced by rock properties. .... oxide of 0.97%, chromium oxide, iron oxide, ... non-oxidised schist, silicon dioxide was again the ... minerals such as titanium oxide, chromium oxide,.

  19. Template-synthesized opal hydrogels

    Institute of Scientific and Technical Information of China (English)

    LI Jun; JI Lijun; RONG Jianhua; YANG Zhenzhong

    2003-01-01

    Opal hydrogels could be synthesized with polymer inverse opal template. A pH responsive opal N-iso- propylacrylamide/acrylic acid copolymerized hydrogel was prepared as an example. The ordered structure and response to pH were investigated. Through the sol-gel process of tetrabutyl titanate, opal titania was obtained with the opal hydrogel template.

  20. Fabrication of poly(ethylene glycol) hydrogel microstructures using photolithography

    Science.gov (United States)

    Revzin, A.; Russell, R. J.; Yadavalli, V. K.; Koh, W. G.; Deister, C.; Hile, D. D.; Mellott, M. B.; Pishko, M. V.

    2001-01-01

    The fabrication of hydrogel microstructures based upon poly(ethylene glycol) diacrylates, dimethacrylates, and tetraacrylates patterned photolithographically on silicon or glass substrates is described. A silicon/silicon dioxide surface was treated with 3-(trichlorosilyl)propyl methacrylate to form a self-assembled monolayer (SAM) with pendant acrylate groups. The SAM presence on the surface was verified using ellipsometry and time-of-flight secondary ion mass spectrometry. A solution containing an acrylated or methacrylated poly(ethylene glycol) derivative and a photoinitiator (2,2-dimethoxy-2-phenylacetophenone) was spin-coated onto the treated substrate, exposed to 365 nm ultraviolet light through a photomask, and developed with either toluene, water, or supercritical CO2. As a result of this process, three-dimensional, cross-linked PEG hydrogel microstructures were immobilized on the surface. Diameters of cylindrical array members were varied from 600 to 7 micrometers by the use of different photomasks, while height varied from 3 to 12 micrometers, depending on the molecular weight of the PEG macromer. In the case of 7 micrometers diameter elements, as many as 400 elements were reproducibly generated in a 1 mm2 square pattern. The resultant hydrogel patterns were hydrated for as long as 3 weeks without delamination from the substrate. In addition, micropatterning of different molecular weights of PEG was demonstrated. Arrays of hydrogel disks containing an immobilized protein conjugated to a pH sensitive fluorophore were also prepared. The pH sensitivity of the gel-immobilized dye was similar to that in an aqueous buffer, and no leaching of the dye-labeled protein from the hydrogel microstructure was observed over a 1 week period. Changes in fluorescence were also observed for immobilized fluorophore labeled acetylcholine esterase upon the addition of acetyl acholine.

  1. Surface property modification of silicon

    Science.gov (United States)

    Danyluk, S.

    1984-01-01

    The main emphasis of this work has been to determine the wear rate of silicon in fluid environments and the parameters that influence wear. Three tests were carried out on single crystal Czochralski silicon wafers: circular and linear multiple-scratch tests in fluids by a pyramidal diamond simulated fixed-particle abrasion; microhardness and three-point bend tests were used to determine the hardness and fracture toughness of abraded silicon and the extent of damage induced by abrasion. The wear rate of (100) and (111) n and p-type single crystal Cz silicon abraded by a pyramidal diamond in ethanol, methanol, acetone and de-ionized water was determined by measuring the cross-sectional areas of grooves of the circular and linear multiple-scratch tests. The wear rate depends on the loads on the diamond and is highest for ethanol and lowest for de-ionized water. The surface morphology of the grooves showed lateral and median cracks as well as a plastically deformed region. The hardness and fracture toughness are critical parameters that influence the wear rate. Microhardness tests were conducted to determine the hardness as influenced by fluids. Median cracks and the damage zone surrounding the indentations were also related to the fluid properties.

  2. Hydrogels as a Replacement Material for Damaged Articular Hyaline Cartilage

    Directory of Open Access Journals (Sweden)

    Charlotte M. Beddoes

    2016-06-01

    Full Text Available Hyaline cartilage is a strong durable material that lubricates joint movement. Due to its avascular structure, cartilage has a poor self-healing ability, thus, a challenge in joint recovery. When severely damaged, cartilage may need to be replaced. However, currently we are unable to replicate the hyaline cartilage, and as such, alternative materials with considerably different properties are used. This results in undesirable side effects, including inadequate lubrication, wear debris, wear of the opposing articular cartilage, and weakening of the surrounding tissue. With the number of surgeries for cartilage repair increasing, a need for materials that can better mimic cartilage, and support the surrounding material in its typical function, is becoming evident. Here, we present a brief overview of the structure and properties of the hyaline cartilage and the current methods for cartilage repair. We then highlight some of the alternative materials under development as potential methods of repair; this is followed by an overview of the development of tough hydrogels. In particular, double network (DN hydrogels are a promising replacement material, with continually improving physical properties. These hydrogels are coming closer to replicating the strength and toughness of the hyaline cartilage, while offering excellent lubrication. We conclude by highlighting several different methods of integrating replacement materials with the native joint to ensure stability and optimal behaviour.

  3. Bio-inspired microstructures in collagen type I hydrogel.

    Science.gov (United States)

    Hosseini, Yahya; Verbridge, Scott S; Agah, Masoud

    2015-06-01

    This article presents a novel technique to fabricate complex type I collagen hydrogel structures, with varying depth and width defined by a single fabrication step. This technique takes advantage of reactive ion etching lag to fabricate three-dimensional (3-D) structures in silicon. Then, a polydimethylsiloxane replica was fabricated utilizing soft lithography and used as a stamp on collagen hydrogel to transfer these patterns. Endothelial cells were seeded on the hydrogel devices to measure their interaction with these more physiologically relevant cell culture surfaces. Confocal imaging was utilized to image the hydrogel devices to demonstrate the robustness of the fabrication technique, and to study the cell-extracellular matrix interaction after cell seeding. In this study, we observed that endothelial cells remodeled the sharp scallops of collagen hydrogel structures and compressed the structures with low degree of slope. Such patterning techniques will enhance the physiological relevance of existing 3-D cell culture platforms by providing a technical bridge between the high resolution yet planar techniques of standard lithography with more complex yet low resolution 3-D printing methods.

  4. Effect of antibiotic drops on adverse events during extended lens wear.

    Science.gov (United States)

    Ozkan, Jerome; Willcox, Mark D P; Rathi, Varsha M; Srikanth, Dumpati; Zhu, Hua; de la Jara, Percy Lazon; Naduvilath, Thomas; Holden, Brien A

    2014-01-01

    Overnight lens wear is associated with increased lens contamination and risk of developing a corneal infiltrate or infectious event. Antibacterial lenses have been proposed as a potential strategy for reducing lens contamination. A proof-of-principle study was conducted to investigate what effect control of potential pathogens, through the use of antibiotic eye drops, would have on the incidence of corneal infiltrative events (CIEs) and on the ocular microbiota and lens contamination. This is a prospective, open-label, controlled, parallel-group, 1-month clinical study in which 241 subjects were dispensed with lotrafilcon A silicone hydrogel lenses for 30 days of continuous wear. Subjects were randomized into either test (moxifloxacin 0.5%) or control (rewetting solution) group. One drop was instilled into each eye on waking and before sleeping, while lenses were on-eye. Follow-ups were conducted after one night and 1 month. Lid margin swabs were taken at baseline and at 1 month and worn lenses were aseptically collected at 1 month. The incidence of CIEs was not significantly different between the test (2.6%) and control (3.9%) groups (p = 0.72). Microorganism levels from the test group swabs were significantly lower than those from the control group (p = 0.001). Gram-positive bacteria were less frequently recovered from lower lid swabs from the test group (39.6% vs. 66.0% [p < 0.001], test vs. control, respectively) or from contact lens samples (1.9% vs. 10.5% [p = 0.015], test vs. control, respectively), but there was no difference in gram-negative bacteria (GNB). Corneal infiltrative events were associated with higher levels of lens contamination (p = 0.014) and contamination of lenses with GNB (CIE: 7.3% vs. 0.6% [p = 0.029], GNB contamination vs. no GNB contamination, respectively). Twice-daily antibiotic instillation during continuous wear of lenses did not significantly influence the rate of inflammatory events. Corneal infiltrative events were associated

  5. Effect of filler size on wear resistance of resin cement.

    Science.gov (United States)

    Shinkai, K; Suzuki, S; Katoh, Y

    2001-11-01

    The purpose of this study was to evaluate the effect of filler size on the wear of resin cements. Materials tested included four experimental dual-cure resin cements (Kuraray) consisting of different-sized filler particles. A rectangular box cavity was prepared on the flattened occlusal surface of extracted human molars. Ceramic inlays for the cavities were fabricated using the Cerec 2 system. The Cerec inlays were cemented with the respective cements and adhesive systems according to the manufacturer's directions. The restored surface was finished by wet-grinding with an 800-grit silicon carbide paper. Six specimens were prepared for each resin cement. Half of the specimens were subjected to a three-body wear test for 200,000 cycles, and the others were subjected to a toothbrush abrasion test for 30,000 cycles. The worn surface of each restoration was scanned by a profilometer (Surfcom 475 A) at eight different points for each restoration. The wear value was determined by measuring the vertical gap depth on the profilometric tracings. The data were statistically analyzed by one-way analysis of variance (ANOVA) and Scheffe's test. The results showed that, with increase of filler size, the wear value decreased in the toothbrush test and increased in the three-body wear test. The cement with 0.04-microm filler exhibited the lowest wear value among the materials in the three-body wear test, and the same wear value as the cement with 0.97-microm filler in the toothbrush test. Based upon the results of this study, it is concluded that the wear of resin cements was affected by the filler size as well as the mode of wear test.

  6. Adhesion in hydrogel contacts

    Science.gov (United States)

    Torres, J. R.; Jay, G. D.; Kim, K.-S.; Bothun, G. D.

    2016-05-01

    A generalized thermomechanical model for adhesion was developed to elucidate the mechanisms of dissipation within the viscoelastic bulk of a hyperelastic hydrogel. Results show that in addition to the expected energy release rate of interface formation, as well as the viscous flow dissipation, the bulk composition exhibits dissipation due to phase inhomogeneity morphological changes. The mixing thermodynamics of the matrix and solvent determines the dynamics of the phase inhomogeneities, which can enhance or disrupt adhesion. The model also accounts for the time-dependent behaviour. A parameter is proposed to discern the dominant dissipation mechanism in hydrogel contact detachment.

  7. Supramolecular Hydrogelators and Hydrogels: From Soft Matter to Molecular Biomaterials

    Science.gov (United States)

    2015-01-01

    In this review we intend to provide a relatively comprehensive summary of the work of supramolecular hydrogelators after 2004 and to put emphasis particularly on the applications of supramolecular hydrogels/hydrogelators as molecular biomaterials. After a brief introduction of methods for generating supramolecular hydrogels, we discuss supramolecular hydrogelators on the basis of their categories, such as small organic molecules, coordination complexes, peptides, nucleobases, and saccharides. Following molecular design, we focus on various potential applications of supramolecular hydrogels as molecular biomaterials, classified by their applications in cell cultures, tissue engineering, cell behavior, imaging, and unique applications of hydrogelators. Particularly, we discuss the applications of supramolecular hydrogelators after they form supramolecular assemblies but prior to reaching the critical gelation concentration because this subject is less explored but may hold equally great promise for helping address fundamental questions about the mechanisms or the consequences of the self-assembly of molecules, including low molecular weight ones. Finally, we provide a perspective on supramolecular hydrogelators. We hope that this review will serve as an updated introduction and reference for researchers who are interested in exploring supramolecular hydrogelators as molecular biomaterials for addressing the societal needs at various frontiers. PMID:26646318

  8. Dry sliding wear of heat treated hybrid metal matrix composites

    Science.gov (United States)

    Naveed, Mohammed; Khan, A. R. Anwar

    2016-09-01

    In recent years, there has been an ever-increasing demand for enhancing mechanical properties of Aluminum Matrix Composites (AMCs), which are finding wide applications in the field of aerospace, automobile, defence etc,. Among all available aluminium alloys, Al6061 is extensively used owing to its excellent wear resistance and ease of processing. Newer techniques of improving the hardness and wear resistance of Al6061 by dispersing an appropriate mixture of hard ceramic powder and whiskers in the aluminium alloy are gaining popularity. The conventional aluminium based composites possess only one type of reinforcements. Addition of hard reinforcements such as silicon carbide, alumina, titanium carbide, improves hardness, strength and wear resistance of the composites. However, these composites possessing hard reinforcement do posses several problems during their machining operation. AMCs reinforced with particles of Gr have been reported to be possessing better wear characteristics owing to the reduced wear because of formation of a thin layer of Gr particles, which prevents metal to metal contact of the sliding surfaces. Further, heat treatment has a profound influence on mechanical properties of heat treatable aluminium alloys and its composites. For a solutionising temperature of 5500C, solutionising duration of 1hr, ageing temperature of 1750C, quenching media and ageing duration significantly alters mechanical properties of both aluminium alloy and its composites. In the light of the above, the present paper aims at developing aluminium based hybrid metal matrix composites containing both silicon carbide and graphite and characterize their mechanical properties by subjecting it to heat treatment. Results indicate that increase of graphite content increases wear resistance of hybrid composites reinforced with constant SiC reinforcement. Further heat treatment has a profound influence on the wear resistance of the matrix alloy as well as its hybrid composites

  9. Effects of some material and experimental variables on the slurry wear characteristics of zinc-aluminum alloys

    Science.gov (United States)

    Prasad, B. K.; Modi, O. P.; Jha, A. K.; Patwardhan, A. K.

    2001-02-01

    In this study, the slurry wear behavior of a zinc-based alloy has been examined by the sample rotation method over a range of traversal speeds and distances. The influence of adding silicon to the alloy system on its wear characteristics has also been examined. The wear rate of the samples increased with increasing traversal distance initially, attained a peak, and then tended to decrease at longer distances. The initial increase in wear rate with distance was attributed to the indenting effect of the slurry constituents ( i.e., liquid droplets and the erodant particles) associated with the corrosive action of the liquid in slurry. On the contrary, factors such as entrapment of the erodant mass as well as the corrosion products in the cavities formed on the specimen surfaces could lead to the decrease in wear rate at longer traversal distances. The existence of silicon particles in the alloy microstructure led to improved wear resistance of the alloy system. This was due to the resistance offered by the hard silicon particles against the impinging action of the slurry constituents. Attainment of the wear rate peak at longer traversal distances in the case of the silicon-containing alloy over the one without the element further substantiated the superior wear resistance offered by the silicon particles. Traversal speed led to higher wear rates irrespective of the test conditions and material composition due to the more severe attack of the medium on the specimen surface. However, the presence of silicon particles in the alloy microstructure offered improved wear resistance (inverse of wear rate).

  10. Optical wear monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Kidane, Getnet S; Desilva, Upul P.; He, Chengli; Ulerich, Nancy H.

    2016-07-26

    A gas turbine includes first and second parts having outer surfaces located adjacent to each other to create an interface where wear occurs. A wear probe is provided for monitoring wear of the outer surface of the first part, and includes an optical guide having first and second ends, wherein the first end is configured to be located flush with the outer surface of the first part. A fiber bundle includes first and second ends, the first end being located proximate to the second end of the optical guide. The fiber bundle includes a transmit fiber bundle comprising a first plurality of optical fibers coupled to a light source, and a receive fiber bundle coupled to a light detector and configured to detect reflected light. A processor is configured to determine a length of the optical guide based on the detected reflected light.

  11. Controlled drug release from hydrogels for contact lenses: Drug partitioning and diffusion.

    Science.gov (United States)

    Pimenta, A F R; Ascenso, J; Fernandes, J C S; Colaço, R; Serro, A P; Saramago, B

    2016-12-30

    Optimization of drug delivery from drug loaded contact lenses assumes understanding the drug transport mechanisms through hydrogels which relies on the knowledge of drug partition and diffusion coefficients. We chose, as model systems, two materials used in contact lens, a poly-hydroxyethylmethacrylate (pHEMA) based hydrogel and a silicone based hydrogel, and three drugs with different sizes and charges: chlorhexidine, levofloxacin and diclofenac. Equilibrium partition coefficients were determined at different ionic strength and pH, using water (pH 5.6) and PBS (pH 7.4). The measured partition coefficients were related with the polymer volume fraction in the hydrogel, through the introduction of an enhancement factor following the approach developed by the group of C. J. Radke (Kotsmar et al., 2012; Liu et al., 2013). This factor may be decomposed in the product of three other factors EHS, Eel and Ead which account for, respectively, hard-sphere size exclusion, electrostatic interactions, and specific solute adsorption. While EHS and Eel are close to 1, Ead>1 in all cases suggesting strong specific interactions between the drugs and the hydrogels. Adsorption was maximal for chlorhexidine on the silicone based hydrogel, in water, due to strong hydrogen bonding. The effective diffusion coefficients, De, were determined from the drug release profiles. Estimations of diffusion coefficients of the non-adsorbed solutes D=De×Ead allowed comparison with theories for solute diffusion in the absence of specific interaction with the polymeric membrane.

  12. Research on a Diamond Tip Wear Mechanism in Atomic Force Microscope-based Micro/nano-machining

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The object is to investigate the wear of an atomic forcemicroscope (AFM) diamond tip when conducting micro/nano-machining on single crystal silicon surface. The experimental research and theoretical analysis were carried out on the worn tip in terms of wear rate, wear mechanism and the effect of the tip wear on micro-machining process. The wear rate was calculated as 1.7(10~10mm3/(N*m) by using a theoretical model combined with the experimental results. Through an integration of an AFM observation on the worn tip features with the FEM simulation of the stress distribution, in addition to the unit cutting force calculation on the AFM diamond tip, the wear mechanism of the AFM diamond tip was concluded as mainly chemical wear, and the wear process was also elaborated as well.

  13. Comparative wear mapping techniques

    DEFF Research Database (Denmark)

    Alcock, J.; Sørensen, Ole Toft; Jensen, S.

    1996-01-01

    Pin surfaces were analysed by laser profilometry. Two roughness parameters, R(a) and the fractal dimension, were investigated as a first step towards methods of quantitative wear mechanism mapping. Both parameters were analysed for their relationship to the severity and prevalence of a mechanism....

  14. Assessment of wear facets produced by the ACTA wear machine

    DEFF Research Database (Denmark)

    Benetti, Ana R; Larsen, Liselotte; Dowling, Adam H

    2016-01-01

    OBJECTIVE: To investigate the use of a three-dimensional (3D) digital scanning method in determining the accuracy of the wear performance parameters of resin-based composites (RBCs) determined using a two-dimensional (2D) analogue methodology following in-vitro testing in an Academisch Centrum...... an assessment of the potential of the experimental RBC formulations for clinical usage. CONCLUSION: The 3D technique allowed for the assessment of mean maximum wear depth and mean total volumetric wear which enables tribological analyses of the wear facet and therefore the wear mechanisms operative. Employing...... profilers is useful when screening potential new RBC formulations for the restoration of posterior dentition....

  15. Poly(ethylene glycol)-containing hydrogel surfaces for antifouling applications in marine and freshwater environments

    NARCIS (Netherlands)

    Ekblad, T.; Bergström, G.; Ederth, T.; Conlan, S.L.; Mutton, R.; Clare, A.S.; Wang, S.; Liu, Y.; Zhao, Q.; D'Souza, F.; Donnelly, G.T.; Willemsen, P.R.; Pettitt, M.E.; Callow, M.E.; Callow, J.A.; Liedberg, B.

    2008-01-01

    This work describes the fabrication, characterization, and biological evaluation of a thin protein-resistant poly(ethylene glycol) (PEG)-based hydrogel coating for antifouling applications. The coating was fabricated by free-radical polymerization on silanized glass and silicon and on polystyrene-co

  16. Poly(ferrocenylsilane) gels and hydrogels with redox-controlled actuation

    NARCIS (Netherlands)

    Hempenius, Mark A.; Cirmi, C.; Cirmi, Concetta; Lo Savio, Fabio; Song, Jing; Vancso, Gyula J.

    2010-01-01

    This concise paper discusses poly(ferrocenylsilane) (PFS)-based organometallic gels and hydrogels as a novel class of redox-responsive materials. First, the use of silicon-bridged spirocyclic [1]ferrocenophane crosslinkers for creating PFS networks swellable in organic solvents is described. Optical

  17. Poly(ferrocenylsilane) Gels and Hydrogels with Redox-Controlled Actuation

    NARCIS (Netherlands)

    Hempenius, Mark A.; Cirmi, Concetta; Savio, Lo Fabio; Song, Jing; Vancso, G. Julius

    2010-01-01

    This concise paper discusses poly(ferrocenylsilane) (PFS)-based organometallic gels and hydrogels as a novel class of redox-responsive materials. First, the use of silicon-bridged spirocyclic [1]ferrocenophane crosslinkers for creating PFS networks swellable in organic solvents is described. Optical

  18. Multifunctional hydrogel nano-probes for atomic force microscopy

    Science.gov (United States)

    Lee, Jae Seol; Song, Jungki; Kim, Seong Oh; Kim, Seokbeom; Lee, Wooju; Jackman, Joshua A.; Kim, Dongchoul; Cho, Nam-Joon; Lee, Jungchul

    2016-05-01

    Since the invention of the atomic force microscope (AFM) three decades ago, there have been numerous advances in its measurement capabilities. Curiously, throughout these developments, the fundamental nature of the force-sensing probe--the key actuating element--has remained largely unchanged. It is produced by long-established microfabrication etching strategies and typically composed of silicon-based materials. Here, we report a new class of photopolymerizable hydrogel nano-probes that are produced by bottom-up fabrication with compressible replica moulding. The hydrogel probes demonstrate excellent capabilities for AFM imaging and force measurement applications while enabling programmable, multifunctional capabilities based on compositionally adjustable mechanical properties and facile encapsulation of various nanomaterials. Taken together, the simple, fast and affordable manufacturing route and multifunctional capabilities of hydrogel AFM nano-probes highlight the potential of soft matter mechanical transducers in nanotechnology applications. The fabrication scheme can also be readily utilized to prepare hydrogel cantilevers, including in parallel arrays, for nanomechanical sensor devices.

  19. Wear Resistance and Wear Mechanism of a Hot Dip Aluminized Steel in Sliding Wear Test

    Science.gov (United States)

    Xue, Zhiyong; Hao, Xiaoyang; Huang, Yao; Gu, Lingyun; Ren, Yu; Zheng, Ruipeng

    2016-12-01

    Sliding wear experiments were conducted on a hot dip aluminized steel to investigate its wear resistance and wear mechanism. The wear tests were also carried out on a hot dip galvanized steel and the base material (steel Q345) as a comparison. Results show that the wear resistance and hardness of the hot dip aluminized steel are significantly higher than that of the hot dip galvanized steel and the steel Q345 at room temperature. The better wear resistance of the hot dip aluminized steel attributes mainly to the formation of a transition layer containing abundant Fe-Al intermetallic compounds and the transformation of wear-resisting oxides during the friction process. The main phase in the transition layer is Fe2Al5. The thickness of the transition layer is about 90-120 μm. When the wear load increases from 3 N to 19 N, the wear type of the aluminized layer transform from adhesive wear (3 N) into abrasive wear (7 N) and finally into slight wear mixed with oxidation (higher than 11 N).

  20. Self-Adjustable Adhesion of Polyampholyte Hydrogels.

    Science.gov (United States)

    Roy, Chanchal Kumar; Guo, Hong Lei; Sun, Tao Lin; Ihsan, Abu Bin; Kurokawa, Takayuki; Takahata, Masakazu; Nonoyama, Takayuki; Nakajima, Tasuku; Gong, Jian Ping

    2015-12-02

    Developing nonspecific, fast, and strong adhesives that can glue hydrogels and biotissues substantially promotes the application of hydrogels as biomaterials. Inspired by the ubiquitous adhesiveness of bacteria, it is reported that neutral polyampholyte hydrogels, through their self-adjustable surface, can show rapid, strong, and reversible adhesion to charged hydrogels and biological tissues through the Coulombic interaction.

  1. TIRE WEAR MODELING

    Directory of Open Access Journals (Sweden)

    Rosen IVANOV

    2016-09-01

    Full Text Available On the basis of a known relationship, an enhanced model for specific tire wear per kilometer has been developed. It is appropriate for practical use - for evaluation of the influence of different factors. Two types of experiments have been carried out with a testing device - one without sideslip, but with a known longitudinal slip, and the other one with the same longitudinal slip but also with a known sideslip. As a result, the coefficients of the proportion of the developed model have been evaluated. After the model validation, an analytical investigation concerning the influence of tire pressure, sideslip and longitudinal slip on the tire wear has been carried out. The results are presented graphically.

  2. Friction and Wear Behavior of Organic Silane/Rare Earth Self-assemblied Composite Film on Silicon%单晶硅表面有机硅烷/稀土复合自组装膜的摩擦磨损性能

    Institute of Scientific and Technical Information of China (English)

    李振华; 程先华

    2011-01-01

    The composite film of nanometer rare-earth/silicon coupling reagent MPTS-MPTES was prepared on the hydroxylated single-crystal silicon substrate by a self-assembling process from specially formulated solution.The resultant composite film was characterized by means of atomic force microscope(AFM) and X-ray photoelectron spectroscopy(XPS).The contact angles of distilled water on the silane SAMs and the composite film were measured to compare the surface states.The tribological properties of the films sliding against GCr15 steel ball were evaluated on a DF-PM static-dynamic friction and wear tester.The experimental results show that rare earth(RE) can be easily incorporated in the MPTS-MPTES SAMs and lead to changed surface state of the composite film.Moreover,MPTS-MPTES / RE composite film is effective in reducing friction and resisting wear compared with MPTS-MPTES SAM as it slides against the steel counterpart at a small load,indicating its promising applications in microelectromechanical system(MEMS) field.%利用分子自组装技术,在单晶硅表面制备了MPTS-MPTES/稀土复合自组装膜.利用接触角测定仪、原子力显微镜和X射线光电子能谱仪分析表征了薄膜的组成和结构;采用DF-PM型静-动摩擦系数精密测定仪评价了薄膜的摩擦磨损性能.研究结果表明:稀土元素可以组装到氧化后的硅烷化表面而形成MPTS-MPTES/稀土自组装复合薄膜.在较低载荷下,薄膜不但摩擦系数较低,同时也表现出良好的耐磨性和摩擦稳定性,显示了其在微型机械表面改性的潜在应用前景.

  3. Stretchable Hydrogel Electronics and Devices.

    Science.gov (United States)

    Lin, Shaoting; Yuk, Hyunwoo; Zhang, Teng; Parada, German Alberto; Koo, Hyunwoo; Yu, Cunjiang; Zhao, Xuanhe

    2016-06-01

    Stretchable hydrogel electronics and devices are designed by integrating stretchable conductors, functional chips, drug-delivery channels, and reservoirs into stretchable, robust, and biocompatible hydrogel matrices. Novel applications include a smart wound dressing capable of sensing the temperatures of various locations on the skin, delivering different drugs to these locations, and subsequently maintaining sustained release of drugs.

  4. Hydrogels with micellar hydrophobic (nanodomains

    Directory of Open Access Journals (Sweden)

    Miloslav ePekař

    2015-01-01

    Full Text Available Hydrogels containing hydrophobic domains or nanodomains, especially of the micellar type, are reviewed. Examples of the reasons for introducing hydrophobic domains into hydrophilic gels are given; typology of these materials is introduced. Synthesis routes are exemplified and properties of a variety of such hydrogels in relation with their intended applications are described. Future research needs are identified briefly.

  5. Engine oil wear resistance

    Directory of Open Access Journals (Sweden)

    A.N. Farhanah

    2015-03-01

    Full Text Available Lubricants play a vital role in an internal combustion engine to lubricate parts and help to protect and prolong the engine life. Lubricant also will help to reduce wear by creating lubricating film between the moving parts hence reduce metal-to-metal contacts. Engine oil from three different manufacturers with the same SAE viscosity grade available in market does not mean it will have the same lubricity for an engine. In this study, commercial mineral lubrication oil (SAE 10W-30 from three manufacturers was investigated to compare the lubrication performance at three different temperatures (40˚C, 70˚C and 100˚C in 60 minutes time duration by using four ball wear tester. The speed will be varied from 1000 rpm to 2500 rpm. Results show that all three lubricants have different lubricity performance; the smaller the wear scar, the better the lubricant since the lubricant can protect the moving surfaces from direct metal-to-metal contact occur.

  6. RESEARCH AND APPLICATION OF AS-CAST WEAR RESISTANCE HIGH CHROMIUM CAST IRON

    Institute of Scientific and Technical Information of China (English)

    1998-01-01

    The influence of alloy elements, such as boron and silicon, on the microstructure and properties of as-cast high chromium cast iron is studied. The results show that boron and silicon have a great effect on the mechanical properties and the wear resistance. Through proper addition of boron and silicon, the properties of as-cast high chromium cast iron can be improved effectively. Through analyzing the distribution of elements by scanning electron microscope, it has been shown that the addition of boron and silicon lowers the mass fraction of chromium saturated in as-cast austenite, and makes it unstable and liable to be transformed into martensite. The as-cast high chromium cast iron with proper content of boron and silicon is suitable for the manufacture of lining for asphalt concrete mixer and its wear resistance is 14 times that of lining made of low alloy white cast iron.

  7. MESO—STRUCTURED POLYMERIC HYDROGELS

    Institute of Scientific and Technical Information of China (English)

    Zhen-zhongYang; Jian-huaRong; DanLi

    2003-01-01

    Meso-structured(opal and inverse opal) polymeric hydrogels of varied morphology and composition were prepared by using two methods:post-modification of the template-synthesized structured polymers and templatepolymerization of functional monomers.A polyacrylic acid based inverse opal hydrogel was chosen to demonstrate its fast pH response by changing color,which is important in designing tunable photonic crystals.Template effects of the hydrogels on controlling structure of the template-synthesized inorganic materials were discussed.The catalytic effect of acid groups in the templates was emphasized for a preferential formation of TiO2 in the region containing acid groups,which allowed duplicating inorganic colloidal crystals from colloidal crystal hydrogels (or macroporous products from macroporous hydrogels) via one step duplication.

  8. MESO-STRUCTURED POLYMERIC HYDROGELS

    Institute of Scientific and Technical Information of China (English)

    Zhen-zhong Yang; Jian-hua Rong; Dan Li

    2003-01-01

    Meso-structured (opal and inverse opal) polymeric hydrogels of varied morphology and composition were prepared by using two methods: post-modification of the template-synthesized structured polymers and templatepolymerization of functional monomers. A polyacrylic acid based inverse opal hydrogel was chosen to demonstrate its fast pH response by changing color, which is important in designing tunable photonic crystals. Template effects of the hydrogels on controlling structure of the template-synthesized inorganic materials were discussed. The catalytic effect of acid groups inthe templates was emphasized for a preferential formation of TiO2 in the region containing acid groups, which allowed duplicating inorganic colloidal crystals from colloidal crystal hydrogels (or macroporous products from macroporous hydrogels) via one step duplication.

  9. Mechanisms for fatigue and wear of polysilicon structural thinfilms

    Energy Technology Data Exchange (ETDEWEB)

    Alsem, Daniel Henricus [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    Fatigue and wear in micron-scale polysilicon structural films can severely impact the reliability of microelectromechanical systems (MEMS). Despite studies on fatigue and wear behavior of these films, there is still an on-going debate regarding the precise physical mechanisms for these two important failure modes. Although macro-scale silicon does not fatigue, this phenomenon is observed in micron-scale silicon. It is shown that for polysilicon devices fabricated in the MUMPs foundry and SUMMiT process stress-lifetime data exhibits similar trends in ambient air, shorter lifetimes in higher relative humidity environments and no fatigue failure at all in high vacuum. Transmission electron microscopy of the surface oxides of the samples show an approximate four-fold thickening of the oxide at stress concentrations after fatigue failure, but no thickening after fracture in air or after fatigue cycling in vacuo. It is found that such oxide thickening and fatigue failure (in air) occurs in devices with initial oxide thicknesses of ~4-20 nm. Such results are interpreted and explained by a reaction layer fatigue mechanism; specifically, moisture-assisted subcritical cracking within a cyclic stress-assisted thickened oxide layer occurs until the crack reaches a critical size to cause catastrophic failure. Polysilicon specimens from the SUMMiT process are used to study wear mechanisms in micron-scale silicon in ambient air. Worn parts are examined by analytical scanning and transmission electron microscopy, while temperature changes are monitored using infrared microscopy. These results are compared with the development of values of static coefficients of friction (COF) with number of wear cycles. Observations show amorphous debris particles (~50-100 nm) created by fracture through the silicon grains (~500 nm), which subsequently oxidize, agglomerate into clusters and create plowing tracks. A nano-crystalline layer (~20-200 nm) forms at worn regions. No dislocations or

  10. Surface chemical modification for exceptional wear life of MEMS materials

    Directory of Open Access Journals (Sweden)

    R. Arvind Singh

    2011-12-01

    Full Text Available Micro-Electro-Mechanical-Systems (MEMS are built at micro/nano-scales. At these scales, the interfacial forces are extremely strong. These forces adversely affect the smooth operation and cause wear resulting in the drastic reduction in wear life (useful operating lifetime of actuator-based devices. In this paper, we present a surface chemical modification method that reduces friction and significantly extends the wear life of the two most popular MEMS structural materials namely, silicon and SU-8 polymer. The method includes surface chemical treatment using ethanolamine-sodium phosphate buffer, followed by coating of perfluoropolyether (PFPE nanolubricant on (i silicon coated with SU-8 thin films (500 nm and (ii MEMS process treated SU-8 thick films (50 μm. After the surface chemical modification, it was observed that the steady-state coefficient of friction of the materials reduced by 4 to 5 times and simultaneously their wear durability increased by more than three orders of magnitude (> 1000 times. The significant reduction in the friction coefficients is due to the lubrication effect of PFPE nanolubricant, while the exceptional increase in their wear life is attributed to the bonding between the -OH functional group of ethanolamine treated SU-8 thin/thick films and the -OH functional group of PFPE. The surface chemical modification method acts as a common route to enhance the performance of both silicon and SU-8 polymer. It is time-effective (process time ≤ 11 min, cost-effective and can be readily integrated into MEMS fabrication/assembly processes. It can also work for any kind of structural material from which the miniaturized devices are/can be made.

  11. Towards Phosphorus Free Ionic Liquid Anti-Wear Lubricant Additives

    Directory of Open Access Journals (Sweden)

    Anthony E. Somers

    2016-06-01

    Full Text Available The development of improved anti-wear additives would enable the use of lower viscosity oils that would lead to improved efficiency. Ionic liquids have the potential to be this type of new anti-wear additive. However, currently the best performing ionic liquids that are miscible in non-polar base oils, the phosphonium phosphates, contain phosphorus on both the cation and anion. Manufacturers are seeking to reduce the presence of phosphorus in oils. Here, as a first step towards phosphorus-free anti-wear additives, we have investigated ionic liquids similar to the phosphonium phosphates but having either a phosphorus-free cation or anion. Two quaternary ammonium phosphates (N6,6,6,14(BEHP and (N8,8,8,8(BEHP and a phosphonium silyl-sulfonate (P6,6,6,14(SSi were compared to a phosphonium phosphate (P6,6,6,14(BEHP and a traditional zinc dithiophosphate (ZDDP as anti-wear additives in mineral oil. The change from a phosphonium to a quaternary ammonium cation drastically reduced the miscibility of the Ionic liquid (IL in the oil, while the change to a smaller silicon containing anion also resulted in limited miscibility. For the pin-on-disk wear test conditions used here none of the ionic liquids outperformed the ZDDP except the (P6,6,6,14(BEHP at a relatively high loading of 0.10 mol·kg−1 (approximately 8 wt%. At a more moderate loading of 0.025 mol·kg−1 the (P6,6,6,14(SSi was the best performing ionic liquid by a significant amount, reducing the wear to 44% of the neat mineral oil, while the ZDDP reduced the wear to 25% of the mineral oil value. Electron microscopy and energy dispersive X-ray spectroscopy showed that the presence of a silicon containing tribofilm was responsible for this protective behaviour, suggesting that silicon containing ionic liquids should be further investigated as anti-wear additives for oils.

  12. Pure mechanical wear loss measurement in corrosive wear

    Indian Academy of Sciences (India)

    Yanliang Huang; Xiaoxia Jiang; Sizuo Li

    2000-12-01

    The method for the measurement of the pure mechanical wear loss for 321 stainless steel, 1045 steel and pure iron in the study of the synergy between corrosion and wear was studied. The methods studied included the measurement in distilled water, by cathodic protection and by adding inhibitor KI, and all were compared with the wear loss in air. The experiment showed that the pure mechanical wear losses and friction coefficients obtained by the three methods were close to each other and can be used to calculate the various wear components in the study of the interaction of corrosion and wear, but the measurements in distilled water for pure iron and 1045 steel are not recommended due to their corrosion.

  13. INCREASING OF WEAR RESISTANCE OF THE GRAPHITIZED STEEL

    Directory of Open Access Journals (Sweden)

    I. V. Akimov

    2013-11-01

    Full Text Available Purpose. Graphitized steels are alloys, in which carbon is partly in form of graphite inclusions. Due to this such steels possess good antifriction properties, wear resistance, heat conductivity and a variety of other mechanical properties, which decently distinguish them from cast irons. However, such steels are not studied enough and practically are not used in mechanical engineering. Purpose of the work is the research of the possibility of wear resistance increase for graphitized steels in the conditions of metal-to-metal dry friction sliding to use them in the railway systems. Methodology. Graphitized hypoeutectoid, eutectoid and hypereutectoid steels have been used as a research material. Experimental alloys have been studied in the condition after thermal hardening. Hardness of alloys has been determined by the Vickers method. Wear resistance of steels has been studied in the conditions of metal-to-metal dry friction sliding with the use of МI-1 friction machine (disk to disk. Findings. Data, which allow assessing the wear resistance of experimental graphitized steels depending on carbon, silicon and copper content have been obtained in this work. The regression dependence obtained as a result of statistical processing of the experimental data allowed determining an optimal chemical content of the steel, which is characterized by high wear resistance. Originality. A dependence describing carbon, silicon and copper content on the specimen's weight loss during metal-to-metal dry friction tests has been obtained in the work. Practical value. The optimized content of the graphitized steel can be used for production of products working in the conditions of wear such as brake blocks of rolling stock, separators of high-speed bearings, dies and others.

  14. Silicon Nitride Balls For Cryogenic Bearings

    Science.gov (United States)

    Butner, Myles F.; Ng, Lillian W.

    1990-01-01

    Resistance to wear greater than that of 440C steel. Experiments show lives of ball bearings immersed in liquid nitrogen or liquid oxygen increased significantly when 440C steel balls (running on 440C steel races) replaced by balls of silicon nitride. Developed for use at high temperatures, where lubrication poor or nonexistent. Best wear life of any bearing tested to date and ball material spalls without fracturing. Plans for future tests call for use of liquid oxygen as working fluid.

  15. Friction, wear, and thermal stability studies of some organotin and organosilicon compounds

    Science.gov (United States)

    Jones, W. R., Jr.

    1973-01-01

    Thermal decomposition temperatures were determined for a number of organotin and organosilicon compounds. A ball-on-disk sliding friction apparatus was used to determine the friction and wear characteristics of two representative compounds, (1) 3-tri-n-butylstannyl (diphenyl) and (2) 3-tri-n-butylsilyl (diphenyl). Friction and wear test conditions included a 1-kg load, 25 to 225 C disk temperatures, and a dry air atmosphere. The tin and silicon compounds yielded friction and wear results either lower than or similar to those obtained with a polyphenyl ether and a C-ether. The maximum thermal decomposition temperatures obtained in the silicon and tin series were 358 and 297 C, respectively. Increasing the steric hindrance around the silicon or tin atoms increased the thermal stability. Future work with these compounds will emphasize their use as antiwear additives rather than base fluids.

  16. Ocular Drug Delivery through pHEMA-Hydrogel Contact Lenses Co-Loaded with Lipophilic Vitamins

    Science.gov (United States)

    Lee, Dasom; Cho, Seungkwon; Park, Hwa Sung; Kwon, Inchan

    2016-01-01

    Ocular drug delivery through hydrogel contact lenses has great potential for the treatment of ocular diseases. Previous studies showed that the loading of lipophilic vitamin E to silicone-hydrogel contact lenses was beneficial in ocular drug delivery. We hypothesized that vitamin E loading to another type of popular hydrogel contact lenses, pHEMA-hydrogel contact lenses, improves ocular drug delivery by increasing the drug loading or the duration of drug release. Loading of vitamin E to pHEMA-hydrogel contact lenses significantly increased the loading of a hydrophilic drug surrogate (Alexa Fluor 488 dye) and two hydrophilic glaucoma drugs (timolol and brimonidine) to the lenses by 37.5%, 19.1%, and 18.7%, respectively. However, the release duration time was not significantly altered. Next, we hypothesized that the lipophilic nature of vitamin E attributes to the enhanced drug loading. Therefore, we investigated the effects of co-loading of another lipophilic vitamin, vitamin A, on drug surrogate delivery. We found out that vitamin A loading also increased the loading of the drug surrogate to pHEMA-hydrogel contact lenses by 30.3%. Similar to vitamin E loading, vitamin A loading did not significantly alter the release duration time of the drug or drug surrogate. PMID:27678247

  17. Ocular Drug Delivery through pHEMA-Hydrogel Contact Lenses Co-Loaded with Lipophilic Vitamins

    Science.gov (United States)

    Lee, Dasom; Cho, Seungkwon; Park, Hwa Sung; Kwon, Inchan

    2016-09-01

    Ocular drug delivery through hydrogel contact lenses has great potential for the treatment of ocular diseases. Previous studies showed that the loading of lipophilic vitamin E to silicone-hydrogel contact lenses was beneficial in ocular drug delivery. We hypothesized that vitamin E loading to another type of popular hydrogel contact lenses, pHEMA-hydrogel contact lenses, improves ocular drug delivery by increasing the drug loading or the duration of drug release. Loading of vitamin E to pHEMA-hydrogel contact lenses significantly increased the loading of a hydrophilic drug surrogate (Alexa Fluor 488 dye) and two hydrophilic glaucoma drugs (timolol and brimonidine) to the lenses by 37.5%, 19.1%, and 18.7%, respectively. However, the release duration time was not significantly altered. Next, we hypothesized that the lipophilic nature of vitamin E attributes to the enhanced drug loading. Therefore, we investigated the effects of co-loading of another lipophilic vitamin, vitamin A, on drug surrogate delivery. We found out that vitamin A loading also increased the loading of the drug surrogate to pHEMA-hydrogel contact lenses by 30.3%. Similar to vitamin E loading, vitamin A loading did not significantly alter the release duration time of the drug or drug surrogate.

  18. Hydrogel wound dressing by radiation

    Energy Technology Data Exchange (ETDEWEB)

    Yoshii, Fumio [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    2002-03-01

    Water soluble polymers such as polyethyleneoxide (PEO), polyvinyl alcohol (PVA) were irradiated in solid and molten states as well as in aqueous solution in order to synthesize a hydrogel. PEO undergoes crosslinking at all phases by radiation initiation. Among these phases, the radiation in the aqueous solution requires the lowest dose for crosslinking due to the contribution of OH radical created in radiolysis of water. The hydrogel prepared by irradiation in aqueous solution was applied to a dressing for healing of wound. In order to evaluate the healing effect of the PEO hydrogel dressing, wounds formed on the back of marmots were covered by the hydrogel. The healing under the wet environment of the hydrogel dressing had three advantages, compared with that of gauze dressing, which gives a dry environment: (1) enhancement of healing rate, (2) facilitation for changing the dressing, i.e. the hydrogel can be peeled off without any damage to the regenerated skin surface, and (3) hydrogel dressing material does not remain stuck on the wound. (author)

  19. Syneresis in agar hydrogels.

    Science.gov (United States)

    Boral, Shilpi; Saxena, Anita; Bohidar, H B

    2010-03-01

    Agar hydrogels exhibit syneresis which creates internal osmotic stress on the physical network. It was observed that such a stress gives rise to characteristic pulsating modes (breathing modes). Experiments carried over a period of 60-day revealed that the network deformations grew monotonously when the solvent released by syneresis was removed periodically from gel surface. However, when the solvent was not withdrawn, the gel exhibited very slowly relaxing breathing modes. The swelling-deswelling dynamics has been discussed in the generalized framework of a dissipative damped oscillator.

  20. Friction and wear calculation methods

    CERN Document Server

    Kragelsky, I V; Kombalov, V S

    1981-01-01

    Friction and Wear: Calculation Methods provides an introduction to the main theories of a new branch of mechanics known as """"contact interaction of solids in relative motion."""" This branch is closely bound up with other sciences, especially physics and chemistry. The book analyzes the nature of friction and wear, and some theoretical relationships that link the characteristics of the processes and the properties of the contacting bodies essential for practical application of the theories in calculating friction forces and wear values. The effect of the environment on friction and wear is a

  1. Wear of polymers and composites

    CERN Document Server

    Abdelbary, Ahmed

    2015-01-01

    In the field of tribology, the wear behaviour of polymers and composite materials is considered a highly non-linear phenomenon. Wear of Polymers and Composites introduces fundamentals of polymers and composites tribology. The book suggests a new approach to explore the effect of applied load and surface defects on the fatigue wear behaviour of polymers, using a new tribometer and thorough experiments. It discusses effects of surface cracks, under different static and cyclic loading parameters on wear, and presents an intelligent algorithm, in the form of a neural network, to map the relations

  2. Tribology of Si/SiO2 in humid air: transition from severe chemical wear to wearless behavior at nanoscale.

    Science.gov (United States)

    Chen, Lei; He, Hongtu; Wang, Xiaodong; Kim, Seong H; Qian, Linmao

    2015-01-13

    Wear at sliding interfaces of silicon is a main cause for material loss in nanomanufacturing and device failure in microelectromechanical system (MEMS) applications. However, a comprehensive understanding of the nanoscale wear mechanisms of silicon in ambient conditions is still lacking. Here, we report the chemical wear of single crystalline silicon, a material used for micro/nanoscale devices, in humid air under the contact pressure lower than the material hardness. A transmission electron microscopy (TEM) analysis of the wear track confirmed that the wear of silicon in humid conditions originates from surface reactions without significant subsurface damages such as plastic deformation or fracture. When rubbed with a SiO2 ball, the single crystalline silicon surface exhibited transitions from severe wear in intermediate humidity to nearly wearless states at two opposite extremes: (a) low humidity and high sliding speed conditions and (b) high humidity and low speed conditions. These transitions suggested that at the sliding interfaces of Si/SiO2 at least two different tribochemical reactions play important roles. One would be the formation of a strong "hydrogen bonding bridge" between hydroxyl groups of two sliding interfaces and the other the removal of hydroxyl groups from the SiO2 surface. The experimental data indicated that the dominance of each reaction varies with the ambient humidity and sliding speed.

  3. In vitro and in vivo evaluation of a hydrogel reservoir as a continuous drug delivery system for inner ear treatment.

    Science.gov (United States)

    Hütten, Mareike; Dhanasingh, Anandhan; Hessler, Roland; Stöver, Timo; Esser, Karl-Heinz; Möller, Martin; Lenarz, Thomas; Jolly, Claude; Groll, Jürgen; Scheper, Verena

    2014-01-01

    Fibrous tissue growth and loss of residual hearing after cochlear implantation can be reduced by application of the glucocorticoid dexamethasone-21-phosphate-disodium-salt (DEX). To date, sustained delivery of this agent to the cochlea using a number of pharmaceutical technologies has not been entirely successful. In this study we examine a novel way of continuous local drug application into the inner ear using a refillable hydrogel functionalized silicone reservoir. A PEG-based hydrogel made of reactive NCO-sP(EO-stat-PO) prepolymers was evaluated as a drug conveying and delivery system in vitro and in vivo. Encapsulating the free form hydrogel into a silicone tube with a small opening for the drug diffusion resulted in delayed drug release but unaffected diffusion of DEX through the gel compared to the free form hydrogel. Additionally, controlled DEX release over several weeks could be demonstrated using the hydrogel filled reservoir. Using a guinea-pig cochlear trauma model the reservoir delivery of DEX significantly protected residual hearing and reduced fibrosis. As well as being used as a device in its own right or in combination with cochlear implants, the hydrogel-filled reservoir represents a new drug delivery system that feasibly could be replenished with therapeutic agents to provide sustained treatment of the inner ear.

  4. In vitro and in vivo evaluation of a hydrogel reservoir as a continuous drug delivery system for inner ear treatment.

    Directory of Open Access Journals (Sweden)

    Mareike Hütten

    Full Text Available Fibrous tissue growth and loss of residual hearing after cochlear implantation can be reduced by application of the glucocorticoid dexamethasone-21-phosphate-disodium-salt (DEX. To date, sustained delivery of this agent to the cochlea using a number of pharmaceutical technologies has not been entirely successful. In this study we examine a novel way of continuous local drug application into the inner ear using a refillable hydrogel functionalized silicone reservoir. A PEG-based hydrogel made of reactive NCO-sP(EO-stat-PO prepolymers was evaluated as a drug conveying and delivery system in vitro and in vivo. Encapsulating the free form hydrogel into a silicone tube with a small opening for the drug diffusion resulted in delayed drug release but unaffected diffusion of DEX through the gel compared to the free form hydrogel. Additionally, controlled DEX release over several weeks could be demonstrated using the hydrogel filled reservoir. Using a guinea-pig cochlear trauma model the reservoir delivery of DEX significantly protected residual hearing and reduced fibrosis. As well as being used as a device in its own right or in combination with cochlear implants, the hydrogel-filled reservoir represents a new drug delivery system that feasibly could be replenished with therapeutic agents to provide sustained treatment of the inner ear.

  5. Synthetically simple, highly resilient hydrogels.

    Science.gov (United States)

    Cui, Jun; Lackey, Melissa A; Madkour, Ahmad E; Saffer, Erika M; Griffin, David M; Bhatia, Surita R; Crosby, Alfred J; Tew, Gregory N

    2012-03-12

    Highly resilient synthetic hydrogels were synthesized by using the efficient thiol-norbornene chemistry to cross-link hydrophilic poly(ethylene glycol) (PEG) and hydrophobic polydimethylsiloxane (PDMS) polymer chains. The swelling and mechanical properties of the hydrogels were controlled by the relative amounts of PEG and PDMS. The fracture toughness (G(c)) was increased to 80 J/m(2) as the water content of the hydrogel decreased from 95% to 82%. In addition, the mechanical energy storage efficiency (resilience) was more than 97% at strains up to 300%. This is comparable with one of the most resilient materials known: natural resilin, an elastic protein found in many insects, such as in the tendons of fleas and the wings of dragonflies. The high resilience of these hydrogels can be attributed to the well-defined network structure provided by the versatile chemistry, low cross-link density, and lack of secondary structure in the polymer chains.

  6. Carbon nanotubes hybrid hydrogels in drug delivery: a perspective review.

    Science.gov (United States)

    Cirillo, Giuseppe; Hampel, Silke; Spizzirri, Umile Gianfranco; Parisi, Ortensia Ilaria; Picci, Nevio; Iemma, Francesca

    2014-01-01

    The use of biologics, polymers, silicon materials, carbon materials, and metals has been proposed for the preparation of innovative drug delivery devices. One of the most promising materials in this field are the carbon-nanotubes composites and hybrid materials coupling the advantages of polymers (biocompatibility and biodegradability) with those of carbon nanotubes (cellular uptake, stability, electromagnatic, and magnetic behavior). The applicability of polymer-carbon nanotubes composites in drug delivery, with particular attention to the controlled release by composites hydrogel, is being extensively investigated in the present review.

  7. Carbon Nanotubes Hybrid Hydrogels in Drug Delivery: A Perspective Review

    Directory of Open Access Journals (Sweden)

    Giuseppe Cirillo

    2014-01-01

    Full Text Available The use of biologics, polymers, silicon materials, carbon materials, and metals has been proposed for the preparation of innovative drug delivery devices. One of the most promising materials in this field are the carbon-nanotubes composites and hybrid materials coupling the advantages of polymers (biocompatibility and biodegradability with those of carbon nanotubes (cellular uptake, stability, electromagnatic, and magnetic behavior. The applicability of polymer-carbon nanotubes composites in drug delivery, with particular attention to the controlled release by composites hydrogel, is being extensively investigated in the present review.

  8. Wear of micro end mills

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2005-01-01

    This paper addresses the important issue of wear on micro end mills considering relevant metrological tools for its characterization and quantification. Investigation of wear on micro end mills is particularly difficult and no data are available in the literature. Small worn volumes cause large d...

  9. Abrasive Wear Resistance of Tool Steels Evaluated by the Pin-on-Disc Testing

    Science.gov (United States)

    Bressan, José Divo; Schopf, Roberto Alexandre

    2011-05-01

    Present work examines tool steels abrasion wear resistance and the abrasion mechanisms which are one main contributor to failure of tooling in metal forming industry. Tooling used in cutting and metal forming processes without lubrication fails due to this type of wear. In the workshop and engineering practice, it is common to relate wear resistance as function of material hardness only. However, there are others parameters which influences wear such as: fracture toughness, type of crystalline structure and the occurrence of hard precipitate in the metallic matrix and also its nature. In the present investigation, the wear mechanisms acting in tool steels were analyzed and, by normalized tests, wear resistance performance of nine different types of tool steels were evaluated by pin-on-disc testing. Conventional tool steels commonly used in tooling such as AISI H13 and AISI A2 were compared in relation to tool steels fabricated by sintering process such as Crucible CPM 3V, CPM 9V and M4 steels. Friction and wear testing were carried out in a pin-on-disc automated equipment which pin was tool steel and the counter-face was a abrasive disc of silicon carbide. Normal load of 5 N, sliding velocity of 0.45 m/s, total sliding distance of 3000 m and room temperature were employed. The wear rate was calculated by the Archard's equation and from the plotted graphs of pin cumulated volume loss versus sliding distance. Specimens were appropriately heat treated by quenching and three tempering cycles. Percentage of alloying elements, metallographic analyses of microstructure and Vickers microhardness of specimens were performed, analyzed and correlated with wear rate. The work is concluded by the presentation of a rank of tool steel wear rate, comparing the different tool steel abrasion wear resistance: the best tool steel wear resistance evaluated was the Crucible CPM 9V steel.

  10. [Infants wearing teething necklaces].

    Science.gov (United States)

    Taillefer, A; Casasoprana, A; Cascarigny, F; Claudet, I

    2012-10-01

    Numerous infants wear teething necklaces, a quack remedy with a real risk of strangulation or aspiration of small beads. Evaluate parental perceptions and beliefs about the use of teething necklaces and analyze parental knowledge about the associated dangers. Between March and July 2011, in three different pediatric units of a tertiary children's hospital and a general hospital in Toulouse and Montauban (southwest France), voluntary parents were invited to be interviewed about their child wearing a teething necklace. The interviews were conducted following an anthropological approach: they were recorded and then fully transcribed and analyzed. Parents were informed that the conversation was recorded. During the study period, 48 children were eligible. Eleven families refused to participate, 29 parents were interviewed face to face. The children's mean age was 14 years ± 7 months, the male:female ratio was equal to 0.8 (12 boys, 15 girls). The mean age of children when necklace wearing was started was equal to 4 ± 2 months. The mean mother's age was 31 ± 5 years and 33 ± 4 years for fathers. The parents' religion was mostly Catholic (60%). Teething necklaces were mainly made of amber (n=23). Sales information about the risks associated with the necklaces was for the most part absent (92%). The most frequent positive parental perceptions were analgesic properties and a soothing remedy (73%); a birth accessory and memory (64%); an esthetic accessory (60%); a protective amulet (60%); and an alternative or additional element to other traditional therapeutics (55%). The negative parental perceptions (n=4) were an unnecessary accessory, costume jewelry, a pure commercial abuse of a popular belief, a dangerous item with a risk of strangulation, and the absence of proof of its efficacy. Although parents concede that teeth eruption is benign, they fear its related symptoms. To a natural phenomenon a natural response: they use a necklace to satisfy the analogy. The

  11. Cytocompatible cellulose hydrogels containing trace lignin.

    Science.gov (United States)

    Nakasone, Kazuki; Kobayashi, Takaomi

    2016-07-01

    Sugarcane bagasse was used as a cellulose resource to prepare transparent and flexible cellulose hydrogel films. On the purification process from bagasse to cellulose, the effect of lignin residues in the cellulose was examined for the properties and cytocompatibility of the resultant hydrogel films. The cellulose was dissolved in lithium chloride/N,N-dimethylacetamide solution and converted to hydrogel films by phase inversion. In the purification process, sodium hydroxide (NaOH) treatment time was changed from 1 to 12h. This resulted in cellulose hydrogel films having small amounts of lignin from 1.62 to 0.68%. The remaining lignin greatly affected hydrogel properties. Water content of the hydrogel films was increased from 1153 to 1525% with a decrease of lignin content. Moreover, lower lignin content caused weakening of tensile strength from 0.80 to 0.43N/mm(2) and elongation from 45.2 to 26.5%. Also, similar tendency was observed in viscoelastic behavior of the cellulose hydrogel films. Evidence was shown that the lignin residue was effective for the high strength of the hydrogel films. In addition, scanning probe microscopy in the morphological observation was suggested that the trace lignin in the cellulose hydrogel affected the cellulose fiber aggregation in the hydrogel network. The trace of lignin in the hydrogels also influenced fibroblast cell culture on the hydrogel films. The hydrogel film containing 1.68% lignin showed better fibroblast compatibility as compared to cell culture polystyrene dish used as reference.

  12. Switch wear leveling

    Science.gov (United States)

    Wu, Hunter; Sealy, Kylee; Gilchrist, Aaron

    2015-09-01

    An apparatus for switch wear leveling includes a switching module that controls switching for two or more pairs of switches in a switching power converter. The switching module controls switches based on a duty cycle control technique and closes and opens each switch in a switching sequence. The pairs of switches connect to a positive and negative terminal of a DC voltage source. For a first switching sequence a first switch of a pair of switches has a higher switching power loss than a second switch of the pair of switches. The apparatus includes a switch rotation module that changes the switching sequence of the two or more pairs of switches from the first switching sequence to a second switching sequence. The second switch of a pair of switches has a higher switching power loss than the first switch of the pair of switches during the second switching sequence.

  13. Energy conversion in polyelectrolyte hydrogels

    Science.gov (United States)

    Olvera de La Cruz, Monica; Erbas, Aykut; Olvera de la Cruz Team

    Energy conversion and storage have been an active field of research in nanotechnology parallel to recent interests towards renewable energy. Polyelectrolyte (PE) hydrogels have attracted considerable attention in this field due to their mechanical flexibility and stimuli-responsive properties. Ideally, when a hydrogel is deformed, applied mechanical work can be converted into electrostatic, elastic and steric-interaction energies. In this talk, we discuss the results of our extensive molecular dynamics simulations of PE hydrogels. We demonstrate that, on deformation, hydrogels adjust their deformed state predominantly by altering electrostatic interactions between their charged groups rather than excluded-volume and bond energies. This is due to the hydrogel's inherent tendency to preserve electro-neutrality in its interior, in combination with correlations imposed by backbone charges. Our findings are valid for a wide range of compression ratios and ionic strengths. The electrostatic-energy alterations that we observe in our MD simulations may induce pH or redox-potential changes inside the hydrogels. The resulting energetic difference can be harvested, for instance, analogously to a Carnot engine, or facilitated for sensor applications. Center for Bio-inspired Energy Science (CBES).

  14. Low friction wear resistant graphene films

    Science.gov (United States)

    Sumant, Anirudha V.; Berman, Diana; Erdemir, Ali

    2017-02-07

    A low friction wear surface with a coefficient of friction in the superlubric regime including graphene and nanoparticles on the wear surface is provided, and methods of producing the low friction wear surface are also provided. A long lifetime wear resistant surface including graphene exposed to hydrogen is provided, including methods of increasing the lifetime of graphene containing wear surfaces by providing hydrogen to the wear surface.

  15. Wear and Reactivity Studies of Melt infiltrated Ceramic Matrix Composite

    Science.gov (United States)

    Jarmon, David C.; Ojard, Greg; Brewer, David N.

    2013-01-01

    As interest grows in the use of ceramic matrix composites (CMCs) for critical gas turbine engine components, the effects of the CMCs interaction with the adjoining structure needs to be understood. A series of CMC/material couples were wear tested in a custom elevated temperature test rig and tested as diffusion couples, to identify interactions. Specifically, melt infiltrated silicon carbide/silicon carbide (MI SiC/SiC) CMC was tested in combination with a nickel-based super alloy, Waspaloy, a thermal barrier coating, Yttria Stabilized Zirconia (YSZ), and a monolithic ceramic, silicon nitride (Si3N4). To make the tests more representative of actual hardware, the surface of the CMC was kept in the as-received state (not machined) with the full surface features/roughness present. Test results include: scanning electron microscope characterization of the surfaces, micro-structural characterization, and microprobe analysis.

  16. Supramolecular hydrogels as drug delivery systems.

    Science.gov (United States)

    Saboktakin, Mohammad Reza; Tabatabaei, Roya Mahdavi

    2015-04-01

    Drug delivery from a hydrogel carrier implanted under the kidney capsule is an innovative way to induce kidney tissue regeneration and/or prevent kidney inflammation or fibrosis. We report here on the development of supramolecular hydrogels for this application. Chain-extended hydrogelators containing hydrogen bonding units in the main chain, and bifunctional hydrogelators end-functionalized with hydrogen bonding moieties, were made. The influence of these hydrogels on the renal cortex when implanted under the kidney capsule was studied. The overall tissue response to these hydrogels was found to be mild, and minimal damage to the cortex was observed, using the infiltration of macrophages, formation of myofibroblasts, and the deposition of collagen III as relevant read-out parameters. Differences in tissue response to these hydrogels could be related to the different physico-chemical properties of the three hydrogels.

  17. Patterns in swelling hydrogels

    Science.gov (United States)

    MacMinn, Chris; Bertrand, Thibault; Peixinho, Jorge; Mukhopadhyay, Shomeek

    2016-11-01

    Swelling is a process in which a porous material spontaneously grows by absorbing additional pore fluid. Polymeric hydrogels are highly deformable materials that can experience very large volume changes during swelling. This allows a small amount of dry gel to absorb a large amount of fluid, making gels extremely useful in applications from moisture control to drug delivery. However, a well-known consequence of these extreme volume changes is the emergence of a striking morphological instability. We study the transient mechanics of this instability here by combining a theoretical model with a series of simple experiments, focusing on the extent to which this instability can be controlled by manipulating the rate of swelling.

  18. Alginate-Collagen Fibril Composite Hydrogel.

    Science.gov (United States)

    Baniasadi, Mahmoud; Minary-Jolandan, Majid

    2015-02-16

    We report on the synthesis and the mechanical characterization of an alginate-collagen fibril composite hydrogel. Native type I collagen fibrils were used to synthesize the fibrous composite hydrogel. We characterized the mechanical properties of the fabricated fibrous hydrogel using tensile testing; rheometry and atomic force microscope (AFM)-based nanoindentation experiments. The results show that addition of type I collagen fibrils improves the rheological and indentation properties of the hydrogel.

  19. Alginate-Collagen Fibril Composite Hydrogel

    Directory of Open Access Journals (Sweden)

    Mahmoud Baniasadi

    2015-02-01

    Full Text Available We report on the synthesis and the mechanical characterization of an alginate-collagen fibril composite hydrogel. Native type I collagen fibrils were used to synthesize the fibrous composite hydrogel. We characterized the mechanical properties of the fabricated fibrous hydrogel using tensile testing; rheometry and atomic force microscope (AFM-based nanoindentation experiments. The results show that addition of type I collagen fibrils improves the rheological and indentation properties of the hydrogel.

  20. Tool wear mechanism in turning of novel wear-resisting aluminum bronze

    Institute of Scientific and Technical Information of China (English)

    倪东惠; 夏伟; 张大童; 郭国文; 邵明

    2003-01-01

    Tool wear and wear mechanism during the turning of a wear-resisting aluminum bronze have been stud-ied. Tool wear samples were prepared by using M2 high-speed steel and YW1 cemented carbide tools to turn a novelhigh strength, wear resisting aluminum bronze without coolant and lubricant. Adhesion of workpiece materials wasfound on tool's surface. Under the turning condition used in this study major wear mechanisms for turning aluminumbronze using M2 high-speed steel tool are diffusion wear, adhesive wear and plastic deformation and shear on thecrater. Partial melting of high-speed steel on the rake plays a role in the tool wear also. Major wear mechanisms forturning aluminum bronze using YW1 cemented carbide tool are diffusion wear, attrition wear and sliding wear. Tocontrol the machining temperature is essential to reduce tool wear.

  1. Magnetically Remanent Hydrogels with Colloidal Crosslinkers

    NARCIS (Netherlands)

    van Berkum, S.

    2014-01-01

    Hydrogels are widely used in biomedical applications such as drug delivery and tissue engineering. In this research, the feasibility of a hydrogel with embedded magnetic nanoparticles, also called a ferrogel, for biosensor applications was tested. A pH sensitive poly(acrylic acid) hydrogel was used

  2. Hydrogels with covalent and noncovalent crosslinks

    Science.gov (United States)

    Kilck, Kristi L. (Inventor); Yamaguchi, Nori (Inventor)

    2013-01-01

    A method for targeted delivery of therapeutic compounds from hydrogels is presented. The method involves administering to a cell a hydrogel in which a therapeutic compound is noncovalently bound to heparin. The hydrogel may contain covalent and non-covalent crosslinks.

  3. Magnetically Remanent Hydrogels with Colloidal Crosslinkers

    NARCIS (Netherlands)

    van Berkum, S.

    2014-01-01

    Hydrogels are widely used in biomedical applications such as drug delivery and tissue engineering. In this research, the feasibility of a hydrogel with embedded magnetic nanoparticles, also called a ferrogel, for biosensor applications was tested. A pH sensitive poly(acrylic acid) hydrogel was used

  4. Preparation and Property Evaluation of Conductive Hydrogel Using Poly (Vinyl Alcohol/Polyethylene Glycol/Graphene Oxide for Human Electrocardiogram Acquisition

    Directory of Open Access Journals (Sweden)

    Xueliang Xiao

    2017-06-01

    Full Text Available Conductive hydrogel combined with Ag/AgCl electrode is widely used in the acquisition of bio-signals. However, the high adhesiveness of current commercial hydrogel causes human skin allergies and pruritus easily after wearing hydrogel for electrodes for a long time. In this paper, a novel conductive hydrogel with good mechanical and conductive performance was prepared using polyvinyl alcohol (PVA, polyethylene glycol (PEG, and graphene oxide (GO nanoparticles. A cyclic freezing–thawing method was employed under processing conditions of −40 °C (8 h and 20 °C (4 h separately for three cycles in sequence until a strong conductive hydrogel, namely, PVA/PEG/GO gel, was obtained. Characterization (Fourier transform infrared spectroscopy, nuclear magnetic resonance, scanning electron microscopy results indicated that the assembled hydrogel was successfully prepared with a three-dimensional network structure and, thereafter, the high strength and elasticity due to the complete polymeric net formed by dense hydrogen bonds in the freezing process. The as-made PVA/PEG/GO hydrogel was then composited with nonwoven fabric for electrocardiogram (ECG electrodes. The ECG acquisition data indicated that the prepared hydrogel has good electro-conductivity and can obtain stable ECG signals for humans in a static state and in motion (with a small amount of drift. A comparison of results indicated that the prepared PVA/PEG/GO gel obtained the same quality of ECG signals with commercial conductive gel with fewer cases of allergies and pruritus in volunteer after six hours of wear.

  5. They shall wear fringes.

    Science.gov (United States)

    Sugar, M

    1999-01-01

    The multiple functions of clothes include utility, protection, rivalry, disguise, camouflage, display for seduction purposes, aggression, totemism, and status. Here the focus is on a decorative and distinctive hierarchical aspect of ancient dress, the tsitsit or fringes, whose original function is long absent, but that has endured for 3,500 years in Judaism. The beginning of their use beyond the totemic appears related to issues of changing identity from slavery to liberty, endowing noble status, exhibitionism, a symbol of identity, identification with the aggressor, a talisman, and potency. It is conceptualized that they became a symbol, or a specifier, that helped promote group cohesion in ex-slaves who were frightened, dependent, anxious, and not hopeful about their future. The tsitsit aided the development of a new identity and made all Israelites equal and noble to the observer. The durability of this symbol to the present is evident in its daily wear, as an accompaniment to daily prayers, as well as in its use as a burial shroud for males. It appears that the tsitsit have additional multiple functions. These are the promise of oral and genital satisfaction, and the pleasure of the after-life, superego warnings and control of sexual impulses, protection, survival value, and affirmation. Since they offer sublimation with acceptable gratification of instincts, the tsitsit have become ritualized and endure.

  6. Intelligent Detection of Drill Wear

    Science.gov (United States)

    Liu, T. I.; Chen, W. Y.; Anatharaman, K. S.

    1998-11-01

    Backpropagation neural networks (BPNs) were used for on-line detection of drill wear. The neural network consisted of three layers: input, hidden, and output. The input vector comprised drill size, feed rate, spindle speed, and eight features obtained by processing the thrust and torque signals. The output was the drill wear state which either usable or failure. Drilling experiments with various drill sizes, feed rates and spindle speeds were carried out. The learning process was performed effectively by utilising backpropagation with smoothing and an activation function slope. The on-line detection of drill wear states using BPNs achieved 100% reliability even when the drill size, feed rate and spindle speed were changed. In other words, the developed on-line drill wear detection systems have very high robustness and hence can be used in very complex production environments, such as flexible manufacturing systems.

  7. Wear resistance properties of austempered ductile iron

    Science.gov (United States)

    Lerner, Y. S.; Kingsbury, G. R.

    1998-02-01

    A detailed review of wear resistance properties of austempered ductile iron (ADI) was undertaken to examine the potential applications of this material for wear parts, as an alternative to steels, alloyed and white irons, bronzes, and other competitive materials. Two modes of wear were studied: adhesive (frictional) dry sliding and abrasive wear. In the rotating dry sliding tests, wear behavior of the base material (a stationary block) was considered in relationship to countersurface (steel shaft) wear. In this wear mode, the wear rate of ADI was only one-fourth that of pearlitic ductile iron (DI) grade 100-70-03; the wear rates of aluminum bronze and leaded-tin bronze, respectively, were 3.7 and 3.3 times greater than that of ADI. Only quenched DI with a fully martensitic matrix slightly outperformed ADI. No significant difference was observed in the wear of steel shafts running against ADI and quenched DI. The excellent wear performance of ADI and its countersurface, combined with their relatively low friction coefficient, indicate potential for dry sliding wear applications. In the abrasive wear mode, the wear rate of ADI was comparable to that of alloyed hardened AISI 4340 steel, and approximately one-half that of hardened medium-carbon AISI 1050 steel and of white and alloyed cast irons. The excellent wear resistance of ADI may be attributed to the strain-affected transformation of high-carbon austenite to martensite that takes place in the surface layer during the wear tests.

  8. The Delamination Theory of Wear

    Science.gov (United States)

    1974-09-01

    junctions, it is still based on the assumption that the deformation occurs at the asperities. Rabinowicz [14] advanced an adhesion theory of friction...shown that bronze particles were indeed bigger than steel particles. The compilation of wear particle sizes given by Rabinowicz [14] also indicates...Waterhouse [32] has shown that, in fact, fretting occurs by delamination. 6) Minimum Load for Loose Particle Formation Rabinowicz [14] found that no wear

  9. The fractal characterization of wear particles in relation to the wear status

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    The topography and distribution of wear particles produced in the wear process containmuch information about the wear status. Fractal geometry is applied in this paper to describe thewear particle accumulation in order to characterize the wear status change. The sliding wear test isperformed on a pin-on-disc apparatus using steel disc and brass pin. The investigation resultsshow that wear particle accumulation presents a strong bi-fractal behavior. Also, the fractal dimen-sion varies in correspondence to the wear status change. A new fractal index characterizing thewear particle accumulation is put forward. The wear tests of brass pin demonstrate that the fractalindex is effective in describing the wear status change.

  10. Critical component wear in heavy duty engines

    CERN Document Server

    Lakshminarayanan, P A

    2011-01-01

    The critical parts of a heavy duty engine are theoretically designed for infinite life without mechanical fatigue failure. Yet the life of an engine is in reality determined by wear of the critical parts. Even if an engine is designed and built to have normal wear life, abnormal wear takes place either due to special working conditions or increased loading.  Understanding abnormal and normal wear enables the engineer to control the external conditions leading to premature wear, or to design the critical parts that have longer wear life and hence lower costs. The literature on wear phenomenon r

  11. Fabrication of poly(ethylene glycol) hydrogel micropatterns with osteoinductive growth factors and evaluation of the effects on osteoblast activity and function

    Science.gov (United States)

    Subramani, K.; Birch, M. A.

    2006-09-01

    The aims of this study were to fabricate poly(ethylene glycol) (PEG) hydrogel micropatterns on a biomaterial surface to guide osteoblast behaviour and to study how incorporating vascular endothelial growth factor (VEGF) within the adhered hydrogel influenced cell morphology. Standard photolithographic procedures or photopolymerization through a poly(dimethyl siloxane) (PDMS) mould were used to fabricate patterned PEG hydrogels on the surface of silanized silicon wafers. Hydrogel patterns were evaluated by light microscopy and surface profilometry. Rat osteoblasts were cultured on these surfaces and cell morphology investigated by fluorescence microscopy, scanning electron microscopy (SEM) and atomic force microscopy (AFM). Release of protein trapped in the polymerized PEG was evaluated and VEGF-PEG surfaces were characterized for their ability to support cell growth. These studies show that photopolymerized PEG can be used to create anti-adhesive structures on the surface of silicon that completely control where cell interaction with the substrate takes place. Using conventional lithography, structures down to 50 µm were routinely fabricated with the boundaries exhibiting sloping sides. Using the PDMS mould approach, structures were fabricated as small as 10 µm and boundaries were very sharp and vertical. Osteoblasts exhibiting typical morphology only grew on the silicon wafer surface that was not coated with PEG. Adding BSA to the monomer solution showed that protein could be released from the hydrogel for up to 7 days in vitro. Incorporating VEGF in the hydrogel produced micropatterns that dramatically altered osteoblast behaviour. At boundaries with the VEGF-PEG hydrogel, there was striking formation of cellular processes and membrane ruffling indicative of a change in cell morphology. This study has explored the morphogenetic properties of VEGF and the applications of nano/microfabrication techniques for guided tissue (bone) regeneration in dental and

  12. Fabrication of poly(ethylene glycol) hydrogel micropatterns with osteoinductive growth factors and evaluation of the effects on osteoblast activity and function

    Energy Technology Data Exchange (ETDEWEB)

    Subramani, K [Institute for Nanoscale Science and Technology (INSAT), University of Newcastle upon Tyne, Newcastle upon Tyne, NE1 7AR (United Kingdom); Birch, M A [Institute for Nanoscale Science and Technology (INSAT), University of Newcastle upon Tyne, Newcastle upon Tyne, NE1 7AR (United Kingdom)

    2006-09-15

    The aims of this study were to fabricate poly(ethylene glycol) (PEG) hydrogel micropatterns on a biomaterial surface to guide osteoblast behaviour and to study how incorporating vascular endothelial growth factor (VEGF) within the adhered hydrogel influenced cell morphology. Standard photolithographic procedures or photopolymerization through a poly(dimethyl siloxane) (PDMS) mould were used to fabricate patterned PEG hydrogels on the surface of silanized silicon wafers. Hydrogel patterns were evaluated by light microscopy and surface profilometry. Rat osteoblasts were cultured on these surfaces and cell morphology investigated by fluorescence microscopy, scanning electron microscopy (SEM) and atomic force microscopy (AFM). Release of protein trapped in the polymerized PEG was evaluated and VEGF-PEG surfaces were characterized for their ability to support cell growth. These studies show that photopolymerized PEG can be used to create anti-adhesive structures on the surface of silicon that completely control where cell interaction with the substrate takes place. Using conventional lithography, structures down to 50 {mu}m were routinely fabricated with the boundaries exhibiting sloping sides. Using the PDMS mould approach, structures were fabricated as small as 10 {mu}m and boundaries were very sharp and vertical. Osteoblasts exhibiting typical morphology only grew on the silicon wafer surface that was not coated with PEG. Adding BSA to the monomer solution showed that protein could be released from the hydrogel for up to 7 days in vitro. Incorporating VEGF in the hydrogel produced micropatterns that dramatically altered osteoblast behaviour. At boundaries with the VEGF-PEG hydrogel, there was striking formation of cellular processes and membrane ruffling indicative of a change in cell morphology. This study has explored the morphogenetic properties of VEGF and the applications of nano/microfabrication techniques for guided tissue (bone) regeneration in dental and

  13. Electrochemical characterization of hydrogels for biomimetic applications

    DEFF Research Database (Denmark)

    Peláez, L.; Romero, V.; Escalera, S.

    2011-01-01

    ) or a photoinitiator (P) to encapsulate and stabilize biomimetic membranes for novel separation technologies or biosensor applications. In this paper, we have investigated the electrochemical properties of the hydrogels used for membrane encapsulation. Specifically, we studied the crosslinked hydrogels by using...... electrochemical impedance spectroscopy (EIS), and we demonstrated that chemically crosslinked hydrogels had lower values for the effective electrical resistance and higher values for the electrical capacitance compared with hydrogels with photoinitiated crosslinking. Transport numbers were obtained using......〉 and 〈Pw〉 values than PEG‐1000‐DMA‐P and PEG‐400‐DA‐P hydrogels. In conclusion, our results show that hydrogel electrochemical properties can be controlled by the choice of polymer and type of crosslinking used and that their water and salt permeability properties are congruent with the use of hydrogels...

  14. Tough photoluminescent hydrogels doped with lanthanide.

    Science.gov (United States)

    Wang, Mei Xiang; Yang, Can Hui; Liu, Zhen Qi; Zhou, Jinxiong; Xu, Feng; Suo, Zhigang; Yang, Jian Hai; Chen, Yong Mei

    2015-03-01

    Photoluminescent hydrogels have emerged as novel soft materials with potential applications in many fields. Although many photoluminescent hydrogels have been fabricated, their scope of usage has been severely limited by their poor mechanical performance. Here, a facile strategy is reported for preparing lanthanide (Ln)-alginate/polyacrylamide (PAAm) hydrogels with both high toughness and photoluminescence, which has been achieved by doping Ln(3+) ions (Ln = Eu, Tb, Eu/Tb) into alginate/PAAm hydrogel networks, where Ln(3+) ions serve as both photoluminescent emitters and physical cross-linkers. The resulting hydrogels exhibit versatile advantages including excellent mechanical properties (∼ MPa strength, ≈ 20 tensile strains, ≈ 10(4) kJ m(-3) energy dissipation), good photoluminescent performance, tunable emission color, excellent processability, and cytocompatibility. The developed tough photoluminescent hydrogels hold great promises for expanding the usage scope of hydrogels.

  15. A Fractional Factorial Design Study of Reciprocating Wear Behavior of Al-Si-SiCp Composites at Lubricated Contacts

    Science.gov (United States)

    Rajeev, V. R.; Dwivedi, D. K.; Jain, S. C.

    2011-04-01

    The lubricated reciprocating wear behavior of two composites A319/15%SiCp and A390/15%SiCp produced by the liquid metallurgy route was investigated by means of an indigenously developed reciprocating friction wear test rig using a fractional factorial-design approach. The main purpose was to study the influence of wear and friction test parameters such as applied load, sliding distance, reciprocating velocity, counter surface temperature and silicon content in composites, as well as their interactions on the wear and friction characteristics of these composites. Two output responses (wear loss and coefficient of friction) were measured. The input parameter levels were fixed through pilot experiment conducted in the newly developed reciprocating friction and wear test rig. The counter surface material used for the wear study was cast iron having Vickers hardness of 244 HVN. It had been demonstrated through established equations that A390/15%SiCp composite is subjected to low wear compared to the A319/15%SiCp composite. The experimental results indicate that the proposed mathematical models suggested could adequately describe the performance indicators within the limits of the factors that are being investigated. The applied load, sliding distance, reciprocating velocity, counter surface temperature, and silicon content in composite are the five important factors controlling the friction and wear characteristics of the composite in lubricated condition. Moreover, the two factor interactions have a strong effect on the wear of composites. The results give a comprehensive insight into the wear of the composites.

  16. A Study on Fretting Wear Property of CVD SiC and Sintered SiC

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Hyun-Jin; Jang, Ki-Nam; An, Ji-Hyeong; Kim, Kyu-Tae [Dongguk University, Gyeongju (Korea, Republic of)

    2015-10-15

    Silicon Carbide is broadly used as high temperature structure material because of its high temperature tolerance and superior mechanical properties. After the Fukushima nuclear power plant accident, SiC proposed as one of the alternative materials for LWR fuel cladding to provide enhanced safety margin. Grid-to-rod fretting wear-induced fuel failure is known to occur due to flow-induced vibration of the reactor core and grid to- rod gap. In this paper, wear tests for CVD SiC plate and sintered SiC tube were performed with two types of spacer grids. Wear test of corroded and non-corroded CVD SiC plates indicate that wear resistance of corroded specimen is lower than one of non-corroded specimen in contrast with zirconium alloy cladding tube. It may be affected by rough surface of corroded specimen caused by grain boundary attack.

  17. Preparation and wear behavior of polymer matrix composites with an interpenetrating network structure derived from natural sponge

    Energy Technology Data Exchange (ETDEWEB)

    Wang Tianchi; Zhou Tianle; Xiong Dangsheng, E-mail: tianchiwang@yahoo.com.c [Department of Material Science and Engineering, Nanjing University of Science and Technology, Nanjing 210094 (China)

    2010-03-15

    Natural sponge was used as a template to produce carbon/epoxy resin and (carbon+silicon carbide)/epoxy resin composites with interpenetrating network structures. Carbon with a network structure was first obtained by pyrolysis of the natural sponge. The composites were then obtained by injecting epoxy resin and silicone resin into the carbon. Their microstructures and wear properties were analyzed. The results show that the natural structure of sponge controlled the interpenetrating network structures of the composites. The netlike carbon in the composites reduced the wear rate of the epoxy resin. Compared with the carbon/epoxy resin composite, the (carbon+silicon carbide)/epoxy resin composite shows better wear resistance.

  18. Visual performance and aberration associated with contact lens wear in patients with keratoconus: a pilot study

    Directory of Open Access Journals (Sweden)

    Abdu M

    2014-08-01

    Full Text Available Mustafa Abdu, Norhani Mohidin, Bariah Mohd-Ali Optometry and Vision Science Program, School of Healthcare Sciences, Faculty of Health Science, Universiti Kebangsaan Malaysia, Jalan Raja Muda Abdul Aziz, Kuala Lumpur, Malaysia Background: Rigid gas permeable (RGP and silicone hydrogel (SH contact lenses with specific designs are currently being used to improve visual function in patients with keratoconus. However, there are minimal data available comparing the effects of these lenses on visual function in patients with keratoconus. The objectives of this study were to compare visual acuity and contrast sensitivity using spectacles, RGP lenses, and SH lenses, and to evaluate the effects of RGP and SH lenses on higher-order aberrations and visual quality in eyes with keratoconus. The relationship between visual outcomes, aberration, and visual quality were also examined. Methods: This was a pilot study involving 13 eyes from nine subjects with keratoconus. Subjects were fitted with RGP and SH contact lenses. Visual acuity and contrast sensitivity were measured using Snellen and Pelli-Robson charts, respectively. Ocular aberrations and visual quality were measured using an OPD-Scan II device. All measurements were conducted before and after contact lens wear. Results: Significantly better visual acuity was obtained with RGP lenses than with spectacles or SH lenses (P<0.001. No significant difference in contrast sensitivity values was detected between RGP and SH lenses (P=0.06. Both SH and RGP lenses significantly reduced total ocular and higher-order aberrations (P<0.001 when compared with spectacles, but RGP lenses reduced trefoil, coma, and spherical aberrations more than SH lenses. No significant difference in astigmatic aberrations was found between RGP and SH lenses (P=0.12. Negative correlations were found between visual acuity and coma aberration and contrast sensitivity with higher-order aberrations and coma, trefoil, and astigmatic

  19. Ultrathin, freestanding, stimuli-responsive, porous membranes from polymer hydrogel-brushes

    Science.gov (United States)

    Kang, Chengjun; Ramakrishna, Shivaprakash N.; Nelson, Adrienne; Cremmel, Clement V. M.; Vom Stein, Helena; Spencer, Nicholas D.; Isa, Lucio; Benetti, Edmondo M.

    2015-07-01

    The fabrication of freestanding, sub-100 nm-thick, pH-responsive hydrogel membranes with controlled nano-morphology, based on modified poly(hydroxyethyl methacrylate) (PHEMA) is presented. Polymer hydrogel-brush films were first synthesized by surface-initiated atom transfer radical polymerization (SI-ATRP) and subsequently detached from silicon substrates by UV-induced photo-cleavage of a specially designed linker within the initiator groups. The detachment was also assisted by pH-induced osmotic forces generated within the films in the swollen state. The mechanical properties and morphology of the freestanding films were studied by atomic force microscopy (AFM). Inclusion of nanopores of controlled diameter was accomplished by performing SI-ATRP from initiator-coated surfaces that had previously been patterned with polystyrene nanoparticles. Assembly parameters and particle sizes could be varied, in order to fabricate nanoporous hydrogel-brush membranes with tunable pore coverage and characteristics. Additionally, due to the presence of weak polyacid functions within the hydrogel, the membranes exhibited pH-dependent thickness in water and reversible opening/closing of the pores.The fabrication of freestanding, sub-100 nm-thick, pH-responsive hydrogel membranes with controlled nano-morphology, based on modified poly(hydroxyethyl methacrylate) (PHEMA) is presented. Polymer hydrogel-brush films were first synthesized by surface-initiated atom transfer radical polymerization (SI-ATRP) and subsequently detached from silicon substrates by UV-induced photo-cleavage of a specially designed linker within the initiator groups. The detachment was also assisted by pH-induced osmotic forces generated within the films in the swollen state. The mechanical properties and morphology of the freestanding films were studied by atomic force microscopy (AFM). Inclusion of nanopores of controlled diameter was accomplished by performing SI-ATRP from initiator-coated surfaces that had

  20. Fabrication of keratin-silica hydrogel for biomedical applications

    Energy Technology Data Exchange (ETDEWEB)

    Kakkar, Prachi; Madhan, Balaraman, E-mail: bmadhan76@yahoo.co.in

    2016-09-01

    In the recent past, keratin has been fabricated into different forms of biomaterials like scaffold, gel, sponge, film etc. In lieu of the myriad advantages of the hydrogels for biomedical applications, a keratin-silica hydrogel was fabricated using tetraethyl orthosilicate (TEOS). Textural analysis shed light on the physical properties of the fabricated hydrogel, inturn enabling the optimization of the hydrogel. The optimized keratin-silica hydrogel was found to exhibit instant springiness, optimum hardness, with ease of spreadability. Moreover, the hydrogel showed excellent swelling with highly porous microarchitecture. MTT assay and DAPI staining revealed that keratin-silica hydrogel was biocompatible with fibroblast cells. Collectively, these properties make the fabricated keratin-silica hydrogel, a suitable dressing material for biomedical applications. - Highlights: • Keratin-silica hydrogel has been fabricated using sol–gel technique. • The hydrogel shows appropriate textural properties. • The hydrogel promotes fibroblast cells proliferation. • The hydrogel has potential soft tissue engineering applications like wound healing.

  1. The High performance of nanocrystalline CVD diamond coated hip joints in wear simulator test.

    Science.gov (United States)

    Maru, M M; Amaral, M; Rodrigues, S P; Santos, R; Gouvea, C P; Archanjo, B S; Trommer, R M; Oliveira, F J; Silva, R F; Achete, C A

    2015-09-01

    The superior biotribological performance of nanocrystalline diamond (NCD) coatings grown by a chemical vapor deposition (CVD) method was already shown to demonstrate high wear resistance in ball on plate experiments under physiological liquid lubrication. However, tests with a close-to-real approach were missing and this constitutes the aim of the present work. Hip joint wear simulator tests were performed with cups and heads made of silicon nitride coated with NCD of ~10 μm in thickness. Five million testing cycles (Mc) were run, which represent nearly five years of hip joint implant activity in a patient. For the wear analysis, gravimetry, profilometry, scanning electron microscopy and Raman spectroscopy techniques were used. After 0.5 Mc of wear test, truncation of the protruded regions of the NCD film happened as a result of a fine-scale abrasive wear mechanism, evolving to extensive plateau regions and highly polished surface condition (Ra<10nm). Such surface modification took place without any catastrophic features as cracking, grain pullouts or delamination of the coatings. A steady state volumetric wear rate of 0.02 mm(3)/Mc, equivalent to a linear wear of 0.27 μm/Mc favorably compares with the best performance reported in the literature for the fourth generation alumina ceramic (0.05 mm(3)/Mc). Also, squeaking, quite common phenomenon in hard-on-hard systems, was absent in the present all-NCD system.

  2. Heparin release from thermosensitive hydrogels

    NARCIS (Netherlands)

    Gutowska, Anna; Bae, You Han; Feijen, Jan; Kim, Sung Wan

    1992-01-01

    Thermosensitive hydrogels (TSH) were synthesized and investigated as heparin releasing polymers for the prevention of surface induced thrombosis. TSH were synthesized with N-isopropyl acrylamide (NiPAAm) copolymerized with butyl methacrylate (BMA) (hydrophobic) or acrylic acid (AAc) (hydrophilic) co

  3. Polyvinyl alcohol hydrogels for iontohporesis

    Science.gov (United States)

    Bera, Prasanta; Alam, Asif Ali; Arora, Neha; Tibarewala, Dewaki Nandan; Basak, Piyali

    2013-06-01

    Transdermal therapeutic systems propound controlled release of active ingredients through the skin into the systemic circulation in a predictive manner. Drugs administered through these systems escape first-pass metabolism and maintain a steady state scenario similar to a continuous intravenous infusion for up to several days. The iontophoresis deal with the systemic delivery of the bioactive agents (drug) by applying an electric current. It is basically an injection without the needle. The iontophoretic system requires a gel-based matrix to accommodate the bioactive agent. Hydrogels have been used by many investigators in controlled-release drug delivery systems because of their good tissue compatibility and easy manipulation of swelling level and, thereby, solute permeability. In this work we have prepared polyvinyl alcohol (PVA) hydrogel. We have cross linked polyvinyl alcohol chemically with Glutaraldehyde with different wt%. FTIR study reveals the chemical changes during cross linking. Swelling in water, is done to have an idea about drug loading and drug release from the membrane. After drug loading to the hydrogels, we have studied the drug release property of the hydrogels using salicylic acid as a model drug.

  4. Hydrogels for therapeutic cardiovascular angiogenesis.

    Science.gov (United States)

    Rufaihah, Abdul Jalil; Seliktar, Dror

    2016-01-15

    Acute myocardial infarction (MI) caused by ischemia is the most common cause of cardiac dysfunction. While growth factor or cell therapy is promising, the retention of bioactive agents in the highly vascularized myocardium is limited and prevents sustained activation needed for adequate cellular responses. Various types of biomaterials with different physical and chemical properties have been developed to improve the localized delivery of growth factor and/or cells for therapeutic angiogenesis in ischemic tissues. Hydrogels are particularly advantageous as carrier systems because they are structurally similar to the tissue extracellular matrix (ECM), they can be processed under relatively mild conditions and can be delivered in a minimally invasive manner. Moreover, hydrogels can be designed to degrade in a timely fashion that coincides with the angiogenic process. For these reasons, hydrogels have shown great potential as pro-angiogenic matrices. This paper reviews a few of the hydrogel systems currently being applied together with growth factor delivery and/or cell therapy to promote therapeutic angiogenesis in ischemic tissues, with emphasis on myocardial applications.

  5. Tribological Wear Behaviour and Hardness Measurement of SiC, Al2O3 Reinforced Al. Matrix Hybrid Composite

    Science.gov (United States)

    Subramanian, Senthil Murugan; Vijayan, Jegan; Muthaiah, Velmurugan

    2017-01-01

    In the present study, Aluminium Matrix Hybrid Composite (AMHC) of 6061-T6 alloy reinforced with silicon carbide (SiC) particulate and further addition of aluminium oxide (Al2O3) particulate was fabricated by stir casting process. The wear resistance and frictional properties of that AMHC were studied by performing dry sliding wear test using a pin on disk wear tester. The experiments were conducted at a constant sliding velocity of 1.57 m/s and sliding distance of 1800 m under loading conditions of 10 and 20 N. Further tests were also carried out by keeping Al2O3 percentage (7%) constant and increasing the SiC percentage (10, 15, and 20%). The results show that the reinforcement of the metal matrix with SiC and Al2O3 reduces the wear rate range and also indicate that the wear of the test specimen increases with the increasing load and sliding distance. The coefficient of friction increases with load and increasing volume content of reinforcement. The worn surfaces were examined by scanning electron microscope to study the wear mechanism. By using wear mechanism analysis, the wear surfaces and wear properties of AMHC were determined.

  6. Calculation of wear (f.i. wear modulus) in the plastic cup of a hip joint prosthesis

    NARCIS (Netherlands)

    Ligterink, D.J.

    1975-01-01

    The wear equation is applied to the wear process in a hip joint prosthesis and a wear modulus is defined. The sliding distance, wear modulus, wear volume, wear area, contact angle and the maximum normal stress were calculated and the theoretical calculations applied to test results. During the wear

  7. Multiscale Modeling of Wear Degradation

    KAUST Repository

    Moraes, Alvaro

    2014-01-06

    Cylinder liners of diesel engines used for marine propulsion are naturally subjected to a wear process, and may fail when their wear exceeds a specified limit. Since failures often represent high economical costs, it is utterly important to predict and avoid them. In this work [4], we model the wear process using a pure jump process. Therefore, the inference goal here is to estimate: the number of possible jumps, its sizes, the coefficients and the shapes of the jump intensities. We propose a multiscale approach for the inference problem that can be seen as an indirect inference scheme. We found that using a Gaussian approximation based on moment expansions, it is possible to accurately estimate the jump intensities and the jump amplitudes. We obtained results equivalent to the state of the art but using a simpler and less expensive approach.

  8. Multiscale Modeling of Wear Degradation

    KAUST Repository

    Moraes, Alvaro

    2016-01-06

    Cylinder liners of diesel engines used for marine propulsion are naturally subjected to a wear process, and may fail when their wear exceeds a specified limit. Since failures often represent high economical costs, it is utterly important to predict and avoid them. In this work [4], we model the wear process using a pure jump process. Therefore, the inference goal here is to estimate: the number of possible jumps, its sizes, the coefficients and the shapes of the jump intensities. We propose a multiscale approach for the inference problem that can be seen as an indirect inference scheme. We found that using a Gaussian approximation based on moment expansions, it is possible to accurately estimate the jump intensities and the jump amplitudes. We obtained results equivalent to the state of the art but using a simpler and less expensive approach.

  9. Multiscale Modeling of Wear Degradation

    KAUST Repository

    Moraes, Alvaro

    2015-01-07

    Cylinder liners of diesel engines used for marine propulsion are naturally subjected to a wear process, and may fail when their wear exceeds a specified limit. Since failures often represent high economical costs, it is utterly important to predict and avoid them. In this work [4], we model the wear process using a pure jump process. Therefore, the inference goal here is to estimate: the number of possible jumps, its sizes, the coefficients and the shapes of the jump intensities. We propose a multiscale approach for the inference problem that can be seen as an indirect inference scheme. We found that using a Gaussian approximation based on moment expansions, it is possible to accurately estimate the jump intensities and the jump amplitudes. We obtained results equivalent to the state of the art but using a simpler and less expensive approach.

  10. Peptide hydrogelation triggered by enzymatic induced pH switch

    Science.gov (United States)

    Cheng, Wei; Li, Ying

    2016-07-01

    It remains challenging to develop methods that can precisely control the self-assembling kinetics and thermodynamics of peptide hydrogelators to achieve hydrogels with optimal properties. Here we report the hydrogelation of peptide hydrogelators by an enzymatically induced pH switch, which involves the combination of glucose oxidase and catalase with D-glucose as the substrate, in which both the gelation kinetics and thermodynamics can be controlled by the concentrations of D-glucose. This novel hydrogelation method could result in hydrogels with higher mechanical stability and lower hydrogelation concentrations. We further illustrate the application of this hydrogelation method to differentiate different D-glucose levels.

  11. An amidated carboxymethylcellulose hydrogel for cartilage regeneration.

    Science.gov (United States)

    Leone, Gemma; Fini, Milena; Torricelli, Paola; Giardino, Roberto; Barbucci, Rolando

    2008-08-01

    An amidic derivative of carboxymethylcellulose was synthesized (CMCA). The new polysaccharide was obtained by converting a large percentage of carboxylic groups ( approximately 50%) of carboxymethylcellulose into amidic groups rendering the macromolecule quite similar to hyaluronan. Then, the polysaccharide (CMCA) was crosslinked. The behavior of CMCA hydrogel towards normal human articular chondrocytes (NHAC) was in vitro studied monitoring the cell proliferation and synthesis of extra cellular matrix (ECM) components and compared with a hyaluronan based hydrogel (Hyal). An extracellular matrix rich in cartilage-specific collagen and proteoglycans was secreted in the presence of hydrogels. The injectability of the new hydrogels was also analysed. An experimental in vivo model was realized to study the effect of CMCA and Hyal hydrogels in the treatment of surgically created partial thickness chondral defects in the rabbit knee. The preliminary results pointed out that CMCA hydrogel could be considered as a potential compound for cartilage regeneration.

  12. Hydrogels for Engineering of Perfusable Vascular Networks.

    Science.gov (United States)

    Liu, Juan; Zheng, Huaiyuan; Poh, Patrina S P; Machens, Hans-Günther; Schilling, Arndt F

    2015-07-14

    Hydrogels are commonly used biomaterials for tissue engineering. With their high-water content, good biocompatibility and biodegradability they resemble the natural extracellular environment and have been widely used as scaffolds for 3D cell culture and studies of cell biology. The possible size of such hydrogel constructs with embedded cells is limited by the cellular demand for oxygen and nutrients. For the fabrication of large and complex tissue constructs, vascular structures become necessary within the hydrogels to supply the encapsulated cells. In this review, we discuss the types of hydrogels that are currently used for the fabrication of constructs with embedded vascular networks, the key properties of hydrogels needed for this purpose and current techniques to engineer perfusable vascular structures into these hydrogels. We then discuss directions for future research aimed at engineering of vascularized tissue for implantation.

  13. Erosive Wear and Wear Mechanism of in situ TiCp/Fe Composites

    Institute of Scientific and Technical Information of China (English)

    Zhaojing LIU; Zhiliang NING; Fengzhen LI; Xiurong YAO; Shanzhi REN

    2005-01-01

    The base structure of in situ TiCP/Fe composites fabricated under industrial condition was changed by different heat treatments. Erosive wear tests were carried out and the results were compared with that of wear-resistant white cast iron. The results suggest that the wear resistance of the in situ TiCp/Fe composite is higher than that of wear-resistant white cast iron under the sand erosive wear condition. The wear mechanism of the wear-resistant white cast iron was a cycle process that base surface was worn and carbides were exposed, then carbides was broken and wear pits appeared. While the wear mechanism of in situ TiCp/Fe composite was a cycle process that base surface was worn and TiC grains were exposed and dropped. The wear resistance of in situ TiCp/Fe composite was lower than that of wear-resistant white cast iron under the slurry erosive wear condition. Under such circumstance,the material was not only undergone erosive wear but also electrochemistry erosion due to the contact with water in the medium. The wear behaviours can be a combination of two kinds of wear and the sand erosive wear is worse than slurry erosive wear.

  14. Wear forms of heterogeneous electro-rheological fluids working in a hydraulic clutch system

    Science.gov (United States)

    Ziabska, E.; Duchowski, J.; Olszak, A.; Osowski, K.; Kesy, A.; Kesy, Z.; Choi, S. B.

    2017-09-01

    The paper presents experimental results concerning the wear of heterogeneous electro-rheological (ER) fluids operating as working fluids in a complex clutch system consisting of a hydrodynamic clutch and a cylinder viscous clutch. The change of electric field intensity in the clutches results in change of sheer stress values in working fluids what causes the change of transmitted torque. This work shows that the most important factors affecting the wear of the ER fluid are the electric field of high intensity, the accompanying electrical breakdown, and the high temperature of the silicone oil. In addition, the water from the humid air absorbed mainly by hygroscopic particles influences a significant impact on the wear of the working fluid. Various forms of wear particles of the fluid depending on the prevailing conditions such as working mode are observed from the microscopic aspects. It is observed that the particles are flattened, rolled out or smashed into smaller fragments, partially melted, wrinkled and glued or caked. In addition, it is identified that the partial destruction of silicone oil is occurred due to the damage of the hydrocarbon chains, as evidenced by the decrease in its viscosity and the presence of the particle matter newly containing silicon.

  15. Injectable, Biodegradable Hydrogels for Tissue Engineering Applications

    Directory of Open Access Journals (Sweden)

    Huaping Tan

    2010-03-01

    Full Text Available Hydrogels have many different applications in the field of regenerative medicine. Biodegradable, injectable hydrogels could be utilized as delivery systems, cell carriers, and scaffolds for tissue engineering. Injectable hydrogels are an appealing scaffold because they are structurally similar to the extracellular matrix of many tissues, can often be processed under relatively mild conditions, and may be delivered in a minimally invasive manner. This review will discuss recent advances in the field of injectable hydrogels, including both synthetic and native polymeric materials, which can be potentially used in cartilage and soft tissue engineering applications.

  16. Photocrosslinkable Gelatin Hydrogel for Epidermal Tissue Engineering.

    Science.gov (United States)

    Zhao, Xin; Lang, Qi; Yildirimer, Lara; Lin, Zhi Yuan; Cui, Wenguo; Annabi, Nasim; Ng, Kee Woei; Dokmeci, Mehmet R; Ghaemmaghami, Amir M; Khademhosseini, Ali

    2016-01-01

    Natural hydrogels are promising scaffolds to engineer epidermis. Currently, natural hydrogels used to support epidermal regeneration are mainly collagen- or gelatin-based, which mimic the natural dermal extracellular matrix but often suffer from insufficient and uncontrollable mechanical and degradation properties. In this study, a photocrosslinkable gelatin (i.e., gelatin methacrylamide (GelMA)) with tunable mechanical, degradation, and biological properties is used to engineer the epidermis for skin tissue engineering applications. The results reveal that the mechanical and degradation properties of the developed hydrogels can be readily modified by varying the hydrogel concentration, with elastic and compressive moduli tuned from a few kPa to a few hundred kPa, and the degradation times varied from a few days to several months. Additionally, hydrogels of all concentrations displayed excellent cell viability (>90%) with increasing cell adhesion and proliferation corresponding to increases in hydrogel concentrations. Furthermore, the hydrogels are found to support keratinocyte growth, differentiation, and stratification into a reconstructed multilayered epidermis with adequate barrier functions. The robust and tunable properties of GelMA hydrogels suggest that the keratinocyte laden hydrogels can be used as epidermal substitutes, wound dressings, or substrates to construct various in vitro skin models.

  17. Should School Nurses Wear Uniforms?

    Science.gov (United States)

    Journal of School Health, 2001

    2001-01-01

    This 1958 paper questions whether school nurses should wear uniforms (specifically, white uniforms). It concludes that white uniforms are often associated with the treatment of ill people, and since many people have a fear reaction to them, they are not necessary and are even undesirable. Since school nurses are school staff members, they should…

  18. Extended release of hyaluronic acid from hydrogel contact lenses for dry eye syndrome.

    Science.gov (United States)

    Maulvi, Furqan A; Soni, Tejal G; Shah, Dinesh O

    2015-01-01

    Current dry eye treatment includes delivering comfort enhancing agents to the eye via eye drops, but low residence time of eye drops leads to low bioavailability. Frequent administration leads to incompliance in patients, so there is a great need for medical device such as contact lenses to treat dry eye. Studies in the past have demonstrated the efficacy of hyaluronic acid (HA) in the treatment of dry eyes using eye drops. In this paper, we present two methods to load HA in hydrogel contact lenses, soaking method and direct entrapment. The contact lenses were characterized by studying their optical and physical properties to determine their suitability as extended wear contact lenses. HA-laden hydrogel contact lenses prepared by soaking method showed release up to 48 h with acceptable physical and optical properties. Hydrogel contact lenses prepared by direct entrapment method showed significant sustained release in comparison to soaking method. HA entrapped in hydrogels resulted in reduction in % transmittance, sodium ion permeability and surface contact angle, while increase in % swelling. The impact on each of these properties was proportional to HA loading. The batch with 200-μg HA loading showed all acceptable values (parameters) for contact lens use. Results of cytotoxicity study indicated the safety of hydrogel contact lenses. In vivo pharmacokinetics studies in rabbit tear fluid showed dramatic increase in HA mean residence time and area under the curve with lenses in comparison to eye drop treatment. The study demonstrates the promising potential of delivering HA through contact lenses for the treatment of dry eye syndrome.

  19. Tooth wear patterns in the deciduous dentition.

    Science.gov (United States)

    Warren, John J; Yonezu, Takuro; Bishara, Samir E

    2002-12-01

    Tooth wear is common in the deciduous dentition. A recent study suggests that tooth wear in the deciduous dentition is related to subsequent tooth wear in adults, so that early identification of factors related to tooth wear could be of long-term benefit. The purposes of this study were to describe patterns of tooth wear in the deciduous dentition and to relate tooth wear to occlusal characteristics and longitudinal dietary patterns. Data were collected as part of a longitudinal study of a cohort of children recruited at birth from Iowa hospitals. Stone casts were obtained in the deciduous dentition stage, and 355 children, 4 to 5 years old, met the selection criteria. Tooth wear was categorized for each tooth as none, mild, moderate, or severe, and related to occlusal characteristics and longitudinal data on fruit juice and soft drink consumption. All children exhibited some tooth wear on at least 1 tooth, and nearly 16% of them had at least 1 tooth with severe wear. Tooth wear was generally more severe in the maxillary arch and the anterior teeth. Severe tooth wear on the molars was significantly related to posterior crossbites, but severe tooth wear on the incisors was related to Class III canine relationships. There were no statistically significant relationships between tooth wear and soft drink or fruit juice consumption. Based on our results, we concluded that mild tooth wear is universal in the deciduous dentition, but only a few occlusal factors are related to severe tooth wear. Tooth wear was not related to any dietary patterns we investigated.

  20. The friction and wear of ceramic/ceramic and ceramic/metal combinations in sliding contact

    Science.gov (United States)

    Sliney, Harold E.; Dellacorte, Christopher

    1994-01-01

    The tribological characteristics of ceramics sliding on ceramics are compared to those of ceramics sliding on a nickel-based turbine alloy. The friction and wear of oxide ceramics and silicon-based ceramics in air at temperatures from room ambient to 900 C (in a few cases to 1200 C) were measured for a hemispherically-tipped pin on a flat sliding contact geometry. In general, especially at high temperature, friction and wear were lower for ceramic/metal combinations than for ceramic/ceramic combinations. The better tribological performance for ceramic/metal combinations is attributed primarily to the lubricious nature of the oxidized surface of the metal.

  1. Improvements of harrows wear resistance

    Directory of Open Access Journals (Sweden)

    Warouma Arifa

    2015-12-01

    Full Text Available Wear is the main reason for the loss of performance of the parts for agricultural machinery. It leads to the degradation of the soil working quality. This work aims to highlight the wear resistance of the harrows discs manufactured, consolidated and sharpened differently. The tests were conducted in the laboratory and the field of the Faculty of Exploitation and Repair of Agricultural Machinery of the State Technical University of Kirovograd (Ukraine in 2015. The technical equipment consists of devices for consolidation by electric discharge and for measurement the linear wear of discs, a harrow, a sand test bed, a tractor and discs made of different materials and technologies. Some parameterized were collected during the laboratory test each 5 ha and up to 20 ha of operation and in the fields each 30 ha until the time limit of exploitation. The Laboratory tests have shown that after twenty (20 ha of operation, the wear resistance of the experimental discs made of steel 65G and consolidated by electric discharge with simultaneous grinding (sharpening angle of 30° is 2.95 times higher than the discs in series made of steel 28MnB5. The field experiment gave the following results: According to agro technical requirements, the plowing depth limit of serial discs made of steel 28MnB5 was reached after an operating duration of 120 ha while for experimental discs made of steel 65G and consolidated by electric discharge with simultaneous grinding (sharpening angle of 30 degrees this duration is of 156 ha. The diameter wear limit of experimental discs was reached after an operating duration of 179 ha against 154 ha for the serial ones. Therefore, the new technology can be applied during the manufacture and / or the repair of the discs.

  2. Friction and Wear Behaviors of Nano-Silicates in Water

    Institute of Scientific and Technical Information of China (English)

    Chen Boshui; Lou Fang; Fang Jianhua; Wang Jiu; Li Jia

    2009-01-01

    Nano-metric magnesium silicate and zinc silicate with particle size of about 50--70nm were prepared in water by the method of chemical deposition. The antiwear and friction reducing abilities of the nano-silicates, as well as their compos-ites with oleie acid tri-ethanolamine (OATEA), were evaluated on a four-ball friction tester. The topographies and tribochemical features of the worn surfaces were analyzed by scanning electron microscope (SEM) and X-ray photoelectron spectroscope (XPS). Results show that nano-silicates alone provide poor antiwear and friction reducing abilities in water, but exhibits excellent synergism with OATEA in reducing friction and wear. The synergism in reducing friction and wear between naao-silicates and OATEA does exist almost regardless of particle sizes and species, and may be attributed, on one hand, to the formation of an adsorption film of OATEA, and, on the other hand, to the formation oftdbochemical species of silicon dioxide and iron oxides on the friction surfaces. Tribo-reactions and tribo-adsorptions of nano-silicates and OATEA would produce hereby an effective composite boondary lubrication film, which could efficiently enhance the anti-wear and friction-reducing abilities of water.

  3. Needs and challenges in precision wear measurement

    Energy Technology Data Exchange (ETDEWEB)

    Blau, P.J.

    1996-01-10

    Accurate, precise wear measurements are a key element in solving both current wear problems and in basic wear research. Applications range from assessing durability of micro-scale components to accurate screening of surface treatments and thin solid films. Need to distinguish small differences in wear tate presents formidable problems to those who are developing new materials and surface treatments. Methods for measuring wear in ASTM standard test methods are discussed. Errors in using alterate methods of wear measurement on the same test specimen are also described. Human judgemental factors are a concern in common methods for wear measurement, and an experiment involving measurement of a wear scar by ten different people is described. Precision in wear measurement is limited both by the capabilities of the measuring instruments and by the nonuniformity of the wear process. A method of measuring wear using nano-scale indentations is discussed. Current and future prospects for incorporating advanced, higher-precision wear measurement methods into standards are considered.

  4. Consideration of Wear Rates at High Velocities

    Science.gov (United States)

    2010-03-01

    tionally, the texts by Bayer [3; 4], Rabinowicz [30], and Stachowiak [32] thoroughly cover the topic of wear mechanisms. A summary of the material is...March 1976. 30. Rabinowicz , E. Friction and Wear of Metals. John Wiley & Sons, New York, 1995. 31. Saka, N., A. M. Eleiche, and N. P. Suh. “Wear of

  5. An Evaluation of High Velocity Wear

    Science.gov (United States)

    2007-03-01

    x10F~ -4 [18:18-19]. Authors such as Hutchings and Rabinowicz however, do not explicitly limit equation (12) to plastic wear. They suggest that...Surface Melting of Rotating Bands. Wear, Vol. 38, 235- 243 21. Rabinowicz , E. (1965). Friction and Wear of Materials (Second ed.). New York, NY

  6. Bundle Formation in Biomimetic Hydrogels.

    Science.gov (United States)

    Jaspers, Maarten; Pape, A C H; Voets, Ilja K; Rowan, Alan E; Portale, Giuseppe; Kouwer, Paul H J

    2016-08-08

    Bundling of single polymer chains is a crucial process in the formation of biopolymer network gels that make up the extracellular matrix and the cytoskeleton. This bundled architecture leads to gels with distinctive properties, including a large-pore-size gel formation at very low concentrations and mechanical responsiveness through nonlinear mechanics, properties that are rarely observed in synthetic hydrogels. Using small-angle X-ray scattering (SAXS), we study the bundle formation and hydrogelation process of polyisocyanide gels, a synthetic material that uniquely mimics the structure and mechanics of biogels. We show how the structure of the material changes at the (thermally induced) gelation point and how factors such as concentration and polymer length determine the architecture, and with that, the mechanical properties. The correlation of the gel mechanics and the structural parameters obtained from SAXS experiments is essential in the design of future (synthetic) mimics of biopolymer networks.

  7. Fewer Bacteria Adhere to Softer Hydrogels

    Science.gov (United States)

    Kolewe, Kristopher W.; Peyton, Shelly R.; Schiffman, Jessica D.

    2015-01-01

    Clinically, biofilm-associated infections commonly form on intravascular catheters and other hydrogel surfaces. The overuse of antibiotics to treat these infections has led to the spread of antibiotic resistance and underscores the importance of developing alternative strategies that delay the onset of biofilm formation. Previously, it has been reported that during surface contact, bacteria can detect surfaces through subtle changes in the function of their motors. However, how the stiffness of a polymer hydrogel influences the initial attachment of bacteria is unknown. Systematically, we investigated poly(ethylene glycol) dimethacrylate (PEGDMA) and agar hydrogels that were twenty times thicker than the cumulative size of bacterial cell appendages, as a function of Young’s moduli. Soft (44.05 – 308.5 kPa), intermediate (1495 – 2877 kPa), and stiff (5152 – 6489 kPa) hydrogels were synthesized. Escherichia coli and Staphylococcus aureus attachment onto the hydrogels was analyzed using confocal microscopy after 2 and 24 hr incubation periods. Independent of hydrogel chemistry and incubation time, E. coli and S. aureus attachment correlated positively to increasing hydrogel stiffness. For example, after a 24 hr incubation period, there were 52% and 82% less E. coli adhered to soft PEGDMA hydrogels, than to the intermediate and stiff PEGDMA hydrogels, respectively. A 62% and 79% reduction in the area coverage by the Gram-positive microbe S. aureus occurred after 24 hr incubation on the soft versus intermediate and stiff PEGDMA hydrogels. We suggest that hydrogel stiffness is an easily tunable variable that, potentially, could be used synergistically with traditional antimicrobial strategies to reduce early bacterial adhesion, and therefore the occurrence of biofilm-associated infections. PMID:26291308

  8. Fewer Bacteria Adhere to Softer Hydrogels.

    Science.gov (United States)

    Kolewe, Kristopher W; Peyton, Shelly R; Schiffman, Jessica D

    2015-09-01

    Clinically, biofilm-associated infections commonly form on intravascular catheters and other hydrogel surfaces. The overuse of antibiotics to treat these infections has led to the spread of antibiotic resistance and underscores the importance of developing alternative strategies that delay the onset of biofilm formation. Previously, it has been reported that during surface contact, bacteria can detect surfaces through subtle changes in the function of their motors. However, how the stiffness of a polymer hydrogel influences the initial attachment of bacteria is unknown. Systematically, we investigated poly(ethylene glycol) dimethacrylate (PEGDMA) and agar hydrogels that were 20 times thicker than the cumulative size of bacterial cell appendages, as a function of Young's moduli. Soft (44.05-308.5 kPa), intermediate (1495-2877 kPa), and stiff (5152-6489 kPa) hydrogels were synthesized. Escherichia coli and Staphylococcus aureus attachment onto the hydrogels was analyzed using confocal microscopy after 2 and 24 h incubation periods. Independent of hydrogel chemistry and incubation time, E. coli and S. aureus attachment correlated positively to increasing hydrogel stiffness. For example, after a 24 h incubation period, there were 52 and 82% fewer E. coli adhered to soft PEGDMA hydrogels than to the intermediate and stiff PEGDMA hydrogels, respectively. A 62 and 79% reduction in the area coverage by the Gram-positive microbe S. aureus occurred after 24 h incubation on the soft versus intermediate and stiff PEGDMA hydrogels. We suggest that hydrogel stiffness is an easily tunable variable that could potentially be used synergistically with traditional antimicrobial strategies to reduce early bacterial adhesion and therefore the occurrence of biofilm-associated infections.

  9. Corrosion and Wear Behaviors of Cr-Doped Diamond-Like Carbon Coatings

    Science.gov (United States)

    Viswanathan, S.; Mohan, L.; Bera, Parthasarathi; Kumar, V. Praveen; Barshilia, Harish C.; Anandan, C.

    2017-08-01

    A combination of plasma-enhanced chemical vapor deposition and magnetron sputtering techniques has been employed to deposit chromium-doped diamond-like carbon (DLC) coatings on stainless steel, silicon and glass substrates. The concentrations of Cr in the coatings are varied by changing the parameters of the bipolar pulsed power supply and the argon/acetylene gas composition. The coatings have been studied for composition, morphology, surface nature, nanohardness, corrosion resistance and wear resistance properties. The changes in I D / I G ratio with Cr concentrations have been obtained from Raman spectroscopy studies. Ratio decreases with an increase in Cr concentration, and it has been found to increase at higher Cr concentration, indicating the disorder in the coating. Carbide is formed in Cr-doped DLC coatings as observed from XPS studies. There is a decrease in sp 3/ sp 2 ratios with an increase in Cr concentration, and it increases again at higher Cr concentration. Nanohardness studies show no clear dependence of hardness on Cr concentration. DLC coatings with lower Cr contents have demonstrated better corrosion resistance with better passive behavior in 3.5% NaCl solution, and corrosion potential is observed to move toward nobler (more positive) values. A low coefficient of friction (0.15) at different loads is observed from reciprocating wear studies. Lower wear volume is found at all loads on the Cr-doped DLC coatings. Wear mechanism changes from abrasive wear on the substrate to adhesive wear on the coating.

  10. Wear Behavior of Woven Roving Aramid / Epoxy Composite under Different Conditions

    Directory of Open Access Journals (Sweden)

    Asad A. Khalid

    2012-09-01

    Full Text Available Wear behavior studies of aramid woven roving /epoxy composite has been conducted. Sliding the material against smooth steel counter face under dry and  lubricated with oil conditions has been investigated. Powder of Silicon carbide has been mixed with the epoxy resin and tested also. The powder was mixed in a volumetric fraction of 10% with the epoxy resin. Four Laminates of six layers were fabricated by hand lay up  method. A pin on disc apparatus has been fabricated to conduct the sliding wear tests on specimens of (4 mm   4 mm   12 mm in size have been cut from the four laminates. The effect of sliding condition including dry, lubricated, dry with additives and lubricated with additives have been studied. Wear rate tests have been conducted at different sliding speeds and loads. Results show that the wear characteristics are influenced by the operating conditions and the construction of the composite material used. It was also found that the wear of aramid /epoxy composite onto the steel counter face were significantly reduced by using lubricant and additives but still took place.Keywords: Wear, Composite materials, Woven roving aramid, Epoxy, Additives, Lubricant.

  11. Bioprinting of 3D hydrogels.

    Science.gov (United States)

    Stanton, M M; Samitier, J; Sánchez, S

    2015-08-07

    Three-dimensional (3D) bioprinting has recently emerged as an extension of 3D material printing, by using biocompatible or cellular components to build structures in an additive, layer-by-layer methodology for encapsulation and culture of cells. These 3D systems allow for cell culture in a suspension for formation of highly organized tissue or controlled spatial orientation of cell environments. The in vitro 3D cellular environments simulate the complexity of an in vivo environment and natural extracellular matrices (ECM). This paper will focus on bioprinting utilizing hydrogels as 3D scaffolds. Hydrogels are advantageous for cell culture as they are highly permeable to cell culture media, nutrients, and waste products generated during metabolic cell processes. They have the ability to be fabricated in customized shapes with various material properties with dimensions at the micron scale. 3D hydrogels are a reliable method for biocompatible 3D printing and have applications in tissue engineering, drug screening, and organ on a chip models.

  12. Effect of Microstructure on Impact Fatigue Resistance and Impact Wear Resistance of Medium Cr-Si Cast Iron

    Institute of Scientific and Technical Information of China (English)

    LI Wei

    2007-01-01

    A great amount of iron grinding balls in tube mills have been consumed. Under this impact abrasive wear working condition, the failure of wear resistant alloying white irons grinding balls is mainly caused by fatigue spalling. The impact wear resistance of martensitic high chromium cast iron (Cr of 15 %) is not high sometimes, but its cost is not low. Thus, medium Cr-Si wear resistant cast iron is recommended. The influence of the iron on impact fatigue resistance and impact wear resistance is pronounced. Ball-on-ball impact fatigue test and high stress impact wear test of the grinding balls have been carried out. The results show that the impact fatigue resistance (IFR) and impact wear resistance (IWR) of medium Cr-Si cast iron are superior to those of martensitic high chromium cast iron (Cr of 15%). The main reasons are that (1) the stress in medium Cr-Si cast iron is released in the as-cast state; (2)the matrix is fine pearlite with better toughness and plasticity; (3) the pearlite is more stable compared with a retained austenite under repeated impact load and less phase transformation can take place; (4) high silicon content improves the morphology of eutectic carbide; (5) there is no secondary carbide which results in less crack sources. All these factors are beneficial to improvement of impact fatigue spalling resistance. The eutectic carbide M7C3 is the main constituent to resist wear.

  13. Evaluation of Photocrosslinked Lutrol Hydrogel for Tissue Printing Applications

    NARCIS (Netherlands)

    Fedorovich, Natalja E.; Swennen, Ives; Girones, Jordi; Moroni, Lorenzo; Blitterswijk, van Clemens A.; Schacht, Etienne; Alblas, Jacqueline; Dhert, Wouter J.A.

    2009-01-01

    Application of hydrogels in tissue engineering and innovative strategies such as organ printing, which is based on layered 3D deposition of cell-laden hydrogels, requires design of novel hydrogel matrices. Hydrogel demands for 3D printing include: 1) preservation of the printed shape after the depos

  14. Rapid Self-Integrating, Injectable Hydrogel for Tissue Complex Regeneration.

    Science.gov (United States)

    Hou, Sen; Wang, Xuefei; Park, Sean; Jin, Xiaobing; Ma, Peter X

    2015-07-15

    A novel rapid self-integrating, injectable, and bioerodible hydrogel is developed for bone-cartilage tissue complex regeneration. The hydrogels are able to self-integrate to form various structures, as can be seen after dying some hydrogel disks pink with rodamine. This hydrogel is demonstrated to engineer cartilage-bone complex.

  15. Evaluation of Photocrosslinked Lutrol Hydrogel for Tissue Printing applications

    NARCIS (Netherlands)

    Fedorovich, Natalja E.; Swennen, Ives; Girones, Jordi; Moroni, Lorenzo; van Blitterswijk, Clemens; Schacht, Etienne; Alblas, Jacqueline; Dhert, Wouter J.A.

    2009-01-01

    Application of hydrogels in tissue engineering and innovative strategies such as organ printing, which is based on layered 3D deposition of cell-laden hydrogels, requires design of novel hydrogel matrices. Hydrogel demands for 3D printing include: 1) preservation of the printed shape after the

  16. Switchable antimicrobial and antifouling hydrogels with enhanced mechanical properties.

    Science.gov (United States)

    Cao, Bin; Tang, Qiong; Li, Linlin; Humble, Jayson; Wu, Haiyan; Liu, Lingyun; Cheng, Gang

    2013-08-01

    New switchable hydrogels are developed. Under acidic conditions, hydrogels undergo self-cyclization and can catch and kill bacteria. Under neutral/basic conditions, hydrogels undergo ring-opening and can release killed bacterial cells and resist protein adsorption and bacterial attachment. Smart hydrogels also show a dramatically improved mechanical property, which is highly desired for biomedical applications.

  17. Sliding wear resistance of iron aluminides

    Indian Academy of Sciences (India)

    Garima Sharma; M Sundararaman; N Prabhu; G L Goswami

    2003-04-01

    Room temperature dry sliding wear behaviour of iron aluminides containing 28% aluminium and various amounts of chromium has been investigated using pin on disk wear tester. The aluminides were heat treated to have ordered 3 structure. It was found that wear rate of the aluminides increased with the increase of applied normal load and sliding speed. Wear resistance of the aluminides increased with increase in chromium content. SEM observation of the worn surface showed that the microcutting and microploughing were the dominant sliding wear mechanisms.

  18. Synthesis of linear low-density polyethylene-g-poly (acrylic acid)-co-starch/organo-montmorillonite hydrogel composite as an adsorbent for removal of Pb(ΙΙ) from aqueous solutions.

    Science.gov (United States)

    Irani, Maryam; Ismail, Hanafi; Ahmad, Zulkifli; Fan, Maohong

    2015-01-01

    The purpose of this work is to remove Pb(II) from the aqueous solution using a type of hydrogel composite. A hydrogel composite consisting of waste linear low density polyethylene, acrylic acid, starch, and organo-montmorillonite was prepared through emulsion polymerization method. Fourier transform infrared spectroscopy (FTIR), Solid carbon nuclear magnetic resonance spectroscopy (CNMR)), silicon(-29) nuclear magnetic resonance spectroscopy (Si NMR)), and X-ray diffraction spectroscope ((XRD) were applied to characterize the hydrogel composite. The hydrogel composite was then employed as an adsorbent for the removal of Pb(II) from the aqueous solution. The Pb(II)-loaded hydrogel composite was characterized using Fourier transform infrared spectroscopy (FTIR)), scanning electron microscopy (SEM)), and X-ray photoelectron spectroscopy ((XPS)). From XPS results, it was found that the carboxyl and hydroxyl groups of the hydrogel composite participated in the removal of Pb(II). Kinetic studies indicated that the adsorption of Pb(II) followed the pseudo-second-order equation. It was also found that the Langmuir model described the adsorption isotherm better than the Freundlich isotherm. The maximum removal capacity of the hydrogel composite for Pb(II) ions was 430mg/g. Thus, the waste linear low-density polyethylene-g-poly (acrylic acid)-co-starch/organo-montmorillonite hydrogel composite could be a promising Pb(II) adsorbent.

  19. Synthesis of linear low-density polyethylene-g-poly (acrylic acid)-co-starch/organo-montmorillonite hydrogel composite as an adsorbent for removal of Pb(Ⅱ) from aqueous solutions

    Institute of Scientific and Technical Information of China (English)

    Maryam Irani; Hanafi Ismail; Zulkifli Ahmad; Maohong Fan

    2015-01-01

    The purpose of this work is to remove Pb(Ⅱ) from the aqueous solution using a type of hydrogel composite.A hydrogel composite consisting of waste linear low density polyethylene,acrylic acid,starch,and organo-montmorillonite was prepared through emulsion polymerization method.Fourier transform infrared spectroscopy (FTIR),Solid carbon nuclear magnetic resonance spectroscopy (CNMR)),silicon-29 nuclear magnetic resonance spectroscopy (Si NMR)),and X-ray diffraction spectroscope ((XRD) were applied to characterize the hydrogel composite.The hydrogel composite was then employed as an adsorbent for the removal of Pb(Ⅱ) from the aqueous solution.The Pb(Ⅱ)-loaded hydrogel composite was characterized using Fourier transform infrared spectroscopy (FTIR)),scanning electron microscopy (SEM)),and X-ray photoelectron spectroscopy ((XPS)).From XPS results,it was found that the carboxyl and hydroxyl groups of the hydrogel composite participated in the removal of Pb(Ⅱ).Kinetic studies indicated that the adsorption of Pb(Ⅱ)followed the pseudo-second-order equation.It was also found that the Langmuir model described the adsorption isotherm better than the Freundlich isotherm.The maximum removal capacity of the hydrogel composite for Pb(Ⅱ) ions was 430 mg/g.Thus,the waste linear low-density polyethylene-g-poly (acrylic acid)-co-starch/organo-montmorillonite hydrogel composite could be a promising Pb(Ⅱ) adsorbent.

  20. Wear prediction in a fluidized bed

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, E.J. [USDOE Morgantown Energy Technology Center, WV (United States); Rogers, W.A. [EG and G Washington Analytical Services Center, Inc., Morgantown, WV (United States)

    1993-06-01

    A procedure to model the wear of surfaces exposed to a fluidized bed is formulated. A stochastic methodology adapting the kinetic theory of gases to granular flows is used to develop an impact wear model. This uses a single-particle wear model to account for impact wear from all possible-particle collisions. An adaptation of a single-particle abrasion model to describe the effects of many abrading particles is used to account for abrasive wear. Parameters describing granular flow within the fluidized bed, necessary for evaluation of the wear expressions, are determined by numerical solution of the fluidized bed hydrodynamic equations. Additional parameters, describing the contact between fluidized particles and the wearing surface, are determined by optimization based on wear measurements. The modeling procedure was used to analyze several bubbling and turbulent fluidized bed experiments with single-tube and tube bundle configurations. Quantitative agreement between the measured and predicted wear rates was found, with some exceptions for local wear predictions. This work demonstrates a methodology for wear predictions in fluidized beds.

  1. Hydrogels with Micellar Hydrophobic (Nano)Domains

    OpenAIRE

    Pekař, Miloslav

    2015-01-01

    Hydrogels containing hydrophobic domains or nanodomains, especially of the micellar type, are reviewed. Examples of the reasons for introducing hydrophobic domains into hydrophilic gels are given; typology of these materials is introduced. Synthesis routes are exemplified and properties of a variety of such hydrogels in relation with their intended applications are described. Future research needs are identified briefly.

  2. Hydrogels with micellar hydrophobic (nano)domains

    OpenAIRE

    Miloslav ePekař

    2015-01-01

    Hydrogels containing hydrophobic domains or nanodomains, especially of the micellar type, are reviewed. Examples of the reasons for introducing hydrophobic domains into hydrophilic gels are given; typology of these materials is introduced. Synthesis routes are exemplified and properties of a variety of such hydrogels in relation with their intended applications are described. Future research needs are identified briefly.

  3. Flexible hydrogel-based functional composite materials

    Science.gov (United States)

    Song, Jie; Saiz, Eduardo; Bertozzi, Carolyn R; Tomasia, Antoni P

    2013-10-08

    A composite having a flexible hydrogel polymer formed by mixing an organic phase with an inorganic composition, the organic phase selected from the group consisting of a hydrogel monomer, a crosslinker, a radical initiator, and/or a solvent. A polymerization mixture is formed and polymerized into a desired shape and size.

  4. Impermeable Robust Hydrogels via Hybrid Lamination.

    Science.gov (United States)

    Parada, German A; Yuk, Hyunwoo; Liu, Xinyue; Hsieh, Alex J; Zhao, Xuanhe

    2017-07-17

    Hydrogels have been proposed for sensing, drug delivery, and soft robotics applications, yet most of these materials suffer from low mechanical robustness and high permeability to small molecules, limiting their widespread use. This study reports a general strategy and versatile method to fabricate robust, highly stretchable, and impermeable hydrogel laminates via hybrid lamination of an elastomer layer bonded between hydrogel layers. By controlling the layers' composition and thickness, it is possible to tune the stiffness of the impermeable hydrogels without sacrificing the stretchability. These hydrogel laminates exhibit ultralow surface coefficients of friction and, unlike common single-material hydrogels, do not allow diffusion of various molecules across the structure due to the presence of the elastomer layer. This feature is then used to release different model drugs and, in a subsequent experiment, to sense different pH conditions on the two sides of the hydrogel laminate. A potential healthcare application is shown using the presented method to coat medical devices (catheter, tubing, and condom) with hydrogel, to allow for drug release and sensing of environmental conditions for gastrointestinal or urinary tract. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Photopatterning of hydrogel microarryas in closed microchips

    NARCIS (Netherlands)

    Gümüscü, B.; Bomer, Johan G.; van den Berg, Albert; Eijkel, Jan C.T.

    2015-01-01

    To date, optical lithography has been extensively used for in situ patterning of hydrogel structures in a scale range from hundreds of microns to a few millimeters. The two main limitations which prevent smaller feature sizes of hydrogel structures are (1) the upper glass layer of a microchip

  6. Hydrogels with micellar hydrophobic (nano)domains

    Science.gov (United States)

    Pekař, Miloslav

    2014-12-01

    Hydrogels containing hydrophobic domains or nanodomains, especially of the micellar type, are reviewed. Examples of the reasons for introducing hydrophobic domains into hydrophilic gels are given; typology of these materials is introduced. Synthesis routes are exemplified and properties of a variety of such hydrogels in relation with their intended applications are described. Future research needs are identified briefly.

  7. Photopatterning of hydrogel microarryas in closed microchips

    NARCIS (Netherlands)

    Gumuscu, Burcu; Bomer, Johan G.; Berg, van den Albert; Eijkel, Jan C.T.

    2015-01-01

    To date, optical lithography has been extensively used for in situ patterning of hydrogel structures in a scale range from hundreds of microns to a few millimeters. The two main limitations which prevent smaller feature sizes of hydrogel structures are (1) the upper glass layer of a microchip mainta

  8. Design of Hydrogels for Biomedical Applications.

    Science.gov (United States)

    Kamata, Hiroyuki; Li, Xiang; Chung, Ung-Il; Sakai, Takamasa

    2015-11-18

    Hydrogels are considered key tools for the design of biomaterials, such as wound dressings, drug reservoirs, and temporary scaffolds for cells. Despite their potential, conventional hydrogels have limited applicability under wet physiological conditions because they suffer from the uncontrollable temporal change in shape: swelling takes place immediately after the installation. Swollen hydrogels easily fail under mechanical stress. The morphological change may cause not only the slippage from the installation site but also local nerve compression. The design of hydrogels that can retain their original shape and mechanical properties in an aqueous environment is, therefore, of great importance. On the one hand, the controlled degradation of used hydrogels has to be realized in some biomedical applications. This Progress Report provides a brief overview of the recent progress in the development of hydrogels for biomedical applications. Practical approaches to control the swelling properties of hydrogels are discussed. The designs of hydrogels with controlled degradation properties as well as the theoretical models to predict the degradation behavior are also introduced. Moreover, current challenges and limitation toward biomedical applications are discussed, and future directions are offered.

  9. Soy-based Hydrogels for Biomedical Applications

    Science.gov (United States)

    Soy based hydrogels were prepared by ring-opening polymerization of epoxidized soybean oil, following hydrolysis of formed polymers. The hydrogels were evaluated loading and releasing water-soluble anticancer drug doxorubin (Dox). The results suggest that this new system offers a great potential t...

  10. Viability of pHEMA Hydrogels as Coating in Human Synovial Joint Prosthesis

    Directory of Open Access Journals (Sweden)

    V.P. Bavaresco

    2002-10-01

    Full Text Available In artificial joints, the bone part is usually substituted by a metallic component with high corrosion and strength resistance while the articular cartilage is replaced by a polymer. Use of thin layer of a compliant material acting as a bearing surface in human replacement joints has recently generated considerable interest. This work analyses the coating of a solid porous substrate of Ultra High Molecular Weight Polyethylene (UHMWPE with a poly (2-hydroxyethyl methacrylate (pHEMA and two sIPN-type blends: pHEMA-cellulose acetate butyrate (CAB and pHEMA-poly (ethyl methacrylate (PEM using 5.0% (w/w of the crosslinking agent and 11.0% (w/w of the linear reinforcing polymer. The wear resistance of the coating materials was evaluated in a TRI PIN ON DISK type equipment and the damage extension was characterized by Scanning Electron Microscopy (SEM. Preliminary qualitative tests were performed with the goal to identifying the hydrogels show the minimal required properties concerning wear strength. The pHEMA coating was completely destroyed during the first wear cycles, characterizing its low shear strength. By the other hand, after the complete experiment, both pHEMA-CAB and pHEMA-PEM blends showed a slightly improvement of abrasive and adhesive wear. This result indicates that the studied blends are promising materials to be used as compliant surfaces in joint prosthesis.

  11. Fluoridation and tooth wear in Irish adults.

    LENUS (Irish Health Repository)

    Burke, F M

    2010-10-01

    The aim of this study was to determine the prevalence of tooth wear in adults in Ireland and its relationship with water fluoridation. The National Survey of Adult Oral Health was conducted in 2000\\/2001. Tooth wear was determined using a partial mouth examination assessing the upper and lower anterior teeth. A total of 2456 subjects were examined. In this survey, increasing levels and severity of tooth wear were associated with ageing. Men were more affected by tooth wear and were more likely to be affected by severe tooth wear than women. It was found that age, and gender were significant predictors of tooth wear (P < 0.01). Overall, there was no significant relationship between fluoridation and tooth wear in this study.

  12. Wear of micro end mills

    DEFF Research Database (Denmark)

    Bissacco, Giuliano; Hansen, Hans Nørgaard; De Chiffre, Leonardo

    2005-01-01

    This paper addresses the important issue of wear on micro end mills considering relevant metrological tools for its characterization and quantification. Investigation of wear on micro end mills is particularly difficult and no data are available in the literature. Small worn volumes cause large...... deviations from the ideal micro tool shape, dramatically changing the cutting edge profile as well as rake and clearance angles. This critically affects the performance of the micro tool leading to increased cutting forces and micro tool deflections with detrimental effects on the accuracy of the machined...... part. For this investigation 200 microns end mills are considered. Visual inspection of the micro tools requires high magnification and depth of focus. 3D reconstruction based on scanning electron microscope (SEM) images and stereo-pair technique is foreseen as a possible method for quantification...

  13. Preparation and characterization of a hydrogel carrier to deliver gatifloxacin and its application as a therapeutic contact lens for bacterial keratitis therapy.

    Science.gov (United States)

    Shi, Yunfeng; Lv, Hongling; Fu, Yeyun; Lu, Qingjun; Zhong, Jingxiang; Ma, Dong; Huang, Yuexin; Xue, Wei

    2013-10-01

    A soft and biocompatible hydrogel exhibiting a higher loading and the sustained release of gatifloxacin (GFLX) was developed as the potential matrix to fabricate a therapeutic contact lens for curing bacterial keratitis. 2-hydroxyethyl methacrylate (HEMA) and five other kinds of vinyl monomers with different side groups were used as co-monomers. Copolymerization took place in a cornea shaped mould via the gradient temperature-elevating method. The results of drug loading and in vitro release experiments showed that P(HEMA-co-MAA) achieved the highest drug loading of 11.78±0.77 µg mg(-1) among the obtained hydrogels, as well as a slow release. In addition, its physical properties and cytocompatibility were also proved suitable and safe for wearing on the eye surface. In animal experiments, a rat model of bacterial keratitis was established and employed to evaluate the clinical results of certain treatments employing obtained hydrogels; saline and GFLX eye drops were used as negative and positive controls, respectively. Corneal abscess and opacity caused by epithelial erosion and stromal ulceration were almost healed after wearing the drug loaded P(HEMA-co-MAA) hydrogel for 48 h. Its excellent antibacterial effect was also confirmed by testing the bacterial activity in tear extraction via the streak line method.

  14. Cellulose/polyvinyl alcohol-based hydrogels for reconfigurable lens

    Science.gov (United States)

    Jayaramudu, T.; Ko, Hyun-U.; Gao, Xiaoyuan; Li, Yaguang; Kim, Sang Youn; Kim, Jaehwan

    2016-04-01

    Electroactive hydrogels are attractive for soft robotics and reconfigurable lens applications. Here we describe the design and fabrication of cellulose-poly vinyl alcohol based hydrogels. The fabricated hydrogels were confirmed by Fourier transformer spectroscopy, swelling studies, thermal analysis, surface morphology of fabricated hydrogel was study by using scanning electron microscopy. The effect of poly vinyl alcohol concentration on the optical and electrical behavior of hydrogels was studied.

  15. Silicon spintronics.

    Science.gov (United States)

    Jansen, Ron

    2012-04-23

    Worldwide efforts are underway to integrate semiconductors and magnetic materials, aiming to create a revolutionary and energy-efficient information technology in which digital data are encoded in the spin of electrons. Implementing spin functionality in silicon, the mainstream semiconductor, is vital to establish a spin-based electronics with potential to change information technology beyond imagination. Can silicon spintronics live up to the expectation? Remarkable advances in the creation and control of spin polarization in silicon suggest so. Here, I review the key developments and achievements, and describe the building blocks of silicon spintronics. Unexpected and puzzling results are discussed, and open issues and challenges identified. More surprises lie ahead as silicon spintronics comes of age.

  16. Multiscale treatment of theoretical mechanisms for the protection of hydrogel surfaces from adhesive forces

    Science.gov (United States)

    Sokoloff, J. B.

    2014-09-01

    One role of a lubricant is to prevent wear of two surfaces in contact, which is likely to be the result of adhesive forces that cause a pair of asperities belonging to two surfaces in contact to stick together. Such adhesive sticking of asperities can occur both for sliding surfaces and for surfaces which are pressed together and then pulled apart. The latter situation, for example, is important for contact lenses, as prevention of sticking reduces possible damage to the cornea as the lenses are inserted and removed from the eye. Contact lenses are made from both neutral and polyelectrolyte hydrogels. It is demonstrated here that sticking of neutral hydrogels can be prevented by repulsive forces between asperities in contact, resulting from polymers attached to the gel surface but not linked with each other. For polyelectrolyte hydrogels, it is shown that osmotic pressure due to counterions, held at the interface between asperities in contact by the electrostatic attraction between the ions and the fixed charges in the gel, can provide a sufficiently strong repulsive force to prevent adhesive sticking of small-length-scale asperities.

  17. Use of Nanofibers to Strengthen Hydrogels of Silica, Other Oxides, and Aerogels

    Science.gov (United States)

    Meador, Mary Ann B.; Capadona, Lynn A.; Hurwitz, Frances; Vivod, Stephanie L.; Lake, Max

    2010-01-01

    Research has shown that including up to 5 percent w/w carbon nanofibers in a silica backbone of polymer crosslinked aerogels improves its strength, tripling compressive modulus and increasing tensile stress-at-break five-fold with no increase in density or decrease in porosity. In addition, the initial silica hydrogels, which are produced as a first step in manufacturing the aerogels, can be quite fragile and difficult to handle before cross-linking. The addition of the carbon nanofiber also improves the strength of the initial hydrogels before cross-linking, improving the manufacturing process. This can also be extended to other oxide aerogels, such as alumina or aluminosilicates, and other nanofiber types, such as silicon carbide.

  18. Wear mechanism and wear prevention in coal-fueled diesel engines. Task 3, Traditional approaches to wear prevention

    Energy Technology Data Exchange (ETDEWEB)

    Schwalb, J.A.

    1991-06-01

    Contamination of the lube-oil with hard abrasive particles leads to a three-body abrasive wear mechanism that highly accelerates piston ring/cylinder liner wear in coal-fueled diesel engines. One approach to reducing that wear is to modify the size and orientation of surface asperities on the cylinder to enhance the formation of a hydrodynamic film, and to provide avenues of escape for particles that would otherwise be trapped in the wear zone. Another approach is to introduce additives into the contaminated lube-oil that further enhance hydrodynamic film formation, form chemical films on the wearing surfaces, or form films on the contaminant particles. This work focuses on defining the effects of cylinder liner surface finish, various configurations of slots in the cylinder liner surface, and various additives in the contaminated lube-oil on the wear process. Wear tests were initiated in a bench apparatus using coal-ash contaminated lube-oil to test the various wear configurations. The results of these tests indicate that the formation of a hydrodynamic film between the ring and cylinder specimens is enhanced by increasing surface roughness, and by orienting the surface asperities normal to the direction of ring travel but modifications to the cylinder liner surface did not greatly reduce the wear rate. Additives to the lubricant seemed to have a much more significant effect on wear, with a dispersant additive highly accelerating the wear, while a detergent additive was able to reduce the wear almost to the rate achieved where there was no contaminant.

  19. A new methodology for predictive tool wear

    Science.gov (United States)

    Kim, Won-Sik

    An empirical approach to tool wear, which requires a series of machining tests for each combination of insert and work material, has been a standard practice for industries since early part of the twentieth century. With many varieties of inserts and work materials available for machining, the empirical approach is too experiment-intensive that the demand for the development of a model-based approach is increasing. With a model-based approach, the developed wear equation can be extended without additional machining experiments. The main idea is that the temperatures on the primary wear areas are increasing such that the physical properties of the tool material degrade substantially and consequently tool wear increases. Dissolution and abrasion are identified to be the main mechanisms for tool wear. Flank wear is predominantly a phenomenon of abrasion as evident by the presence of a scoring mark on the flank surface. Based on this statement, it is reasonable to expect that the flank-wear rate would increase with the content of hard inclusions. However, experimental flank wear results did not necessary correspond to the content of cementite phase present in the steels. Hence, other phenomena are believed to significantly affect wear behavior under certain conditions. When the cutting temperature in the flank interface is subjected to high enough temperatures, pearlitic structure austenizes. During the formation of a new austenitic phase, the existing carbon is dissolved into the ferrite matrix, which will reduce the abrasive action. To verify the austenitic transformation, turning tests were conducted with plain carbon steels. The machined surface areas are imaged using X-ray diffraction the Scanning Electron Microscope (SEM) and the Transmission Electron Microscope (TEM). On the other hand, crater wear occurs as a result of dissolution wear and abrasive wear. To verify the wear mechanisms of crater wear, various coating inserts as well as uncoated inserts were

  20. Orthogonal Enzymatic Reactions to Control Supramolecular Hydrogelations%Orthogonal Enzymatic Reactions to Control Supramolecular Hydrogelations

    Institute of Scientific and Technical Information of China (English)

    陈国钦; 任春华; 王玲; 徐兵; 杨志谋

    2012-01-01

    Enzyme-responsive hydrogels have great potential in applications of controlled drug release, tissue engineering, etc. In this study, we reported on a supramolecular hydrogel that showed responses to two enzymes, phosphatase which was used to form the hydrogels and esterase which could trigger gelsol phase transitions. The gelation process and visco-elasticity property of the resulting gel, morphology of the nanostructures in hydrogel, and peptide conformation in the self-assembled nanostructure were characterized by theology, transmission electron microscope (TEM), and circular dichroism (CD), respectively. Potential application of the enzyme-responsive hydrogel in drug release was also demonstrated in this study. Though only one potential application of drug release was proved in this study, the responsive hydrogel system in this study might have potentials for the applications in fields of cell culture, controlled-drug release, etc.

  1. Mechanics and mechanisms of surface damage in Al-Si alloys under ultra-mild wear conditions

    Science.gov (United States)

    Chen, Ming

    Al-Si alloys intended for use in engine components must operate under ultra-mild wear (UMW) conditions to fit an acceptable amount of wear during a typical vehicle life. This study simulated surface damage in a UMW regime on five chemically etched Al-Si alloy surfaces using a pin-on-disc tribometer at low loads (0.5-2.0 N) under boundary lubricated conditions. The five alloys contained 11 to 25 wt.% Si and differed in matrix hardness, silicon particle morphology, and size. The mechanisms leading to the UMW damage and the role that the matrix hardness and microstructure play on said mechanisms were studied. Quantitative measurement methods based on statistical analysis of particle height changes and material loss from elevated aluminum using a profilometer technique were developed and used to assess UMW. The Greenwood and Tripp's numerical model was adapted to analyze the contact that occurred between Al-Si alloys with silicon particles protruding above the aluminum and steel balls. The estimation of the real contact pressure applied to the silicon particles was used to rationalize the damage mechanisms. The UMW mechanisms consisted of (i) abrasive wear on the top of the silicon particle surfaces; (ii) sinking-in of the silicon particles; (iii) piling-up of the aluminium around sunken-in particles and (vi) wear of the aluminium by the counterface, which eventually led to the initiation of UMW-II. Increasing the size or areal density of silicon particles with small aspect ratios delayed the onset of UMW-II by providing resistance against the silicon particles sinking-in and the aluminum piling-up. The UMW wear rates, however, began to decrease after long sliding cycles once an oil residue layer supported by hardened ultra-fine subsurface grains formed on the deformed aluminium matrix. The layer formation depended on the microstructure and applied load. Overall experimental observations suggested that Al-11% Si with small silicon particles exhibited optimal long

  2. Effect of Fe2B boride orientation on abrasion wear resistance of Fe-B cast alloy

    Directory of Open Access Journals (Sweden)

    Da-wei Yi

    2017-07-01

    Full Text Available The microstructures and abrasion wear resistance of directional solidification Fe-B alloy have been investigated using optical microscopy, X-ray diffraction, scanning electron microscopy and laser scanning microscopy. The results show that the microstructure of as-cast Fe-B alloy consists of ferrite, pearlite and eutectic boride. After heat treatment, the microstructure is composed of boride and martensite. The plane which is perpendicular to the boride growth direction possesses the highest hardness. In two-body abrasive wear tests, the silicon carbide abrasive can cut the boride and martensite matrix synchronously, and the wear mechanism is micro cutting mechanism. The worn surface roughness and the wear weight loss both increase with the increasing contact load. Moreover, when the boride growth direction is perpendicular to the worn surface, the highest hardness plane of the boride can effectively oppose abrasion, and the martensite matrix can surround and support borides perfectly.

  3. Designing hydrogels for controlled drug delivery

    Science.gov (United States)

    Li, Jianyu; Mooney, David J.

    2016-12-01

    Hydrogel delivery systems can leverage therapeutically beneficial outcomes of drug delivery and have found clinical use. Hydrogels can provide spatial and temporal control over the release of various therapeutic agents, including small-molecule drugs, macromolecular drugs and cells. Owing to their tunable physical properties, controllable degradability and capability to protect labile drugs from degradation, hydrogels serve as a platform on which various physiochemical interactions with the encapsulated drugs occur to control drug release. In this Review, we cover multiscale mechanisms underlying the design of hydrogel drug delivery systems, focusing on physical and chemical properties of the hydrogel network and the hydrogel-drug interactions across the network, mesh and molecular (or atomistic) scales. We discuss how different mechanisms interact and can be integrated to exert fine control in time and space over drug presentation. We also collect experimental release data from the literature, review clinical translation to date of these systems and present quantitative comparisons between different systems to provide guidelines for the rational design of hydrogel delivery systems.

  4. RF-interrogatable hydrogel-actuated biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Hoel, Z; Wang, A W; Darrow, C B; Lee, A P; McConaghy, C F; Krulevitch, P; Gilman, A; Satcher, J H; Lane, S M

    2000-01-10

    The authors present a novel micromachined sensor that couples a swellable hydrogel with capacitive detection. The hydrogel swells in response to analyte concentration, exerting contact pressure on a deformable conducting membrane. Results are presented for characterization of a PHEMA hydrogel swelling in response to a calcium nitrate solution. Pressure-deflection measurements are performed on NiTi-based membranes. Hydrogel-actuated deflections of the membranes are measured. These measurements are correlated to determine the pressure generating characteristics of the hydrogel. Membrane deflection techniques have not previously been employed for hydrogel characterization. The PHEMA sample exhibited greatest sensitivity in the pH range of 6.0--6.5 and performed an average of 2.8 Joules of work per m{sup 3} per pH unit in response to ambient conditions over the pH range 3.5--6.5. The membrane deflections correspond to capacitive shifts of about 4 pF per pH unit for a capacitive transducer with initial gap of 100 {micro}m, capacitor plate area of 18.5 mm{sup 2} , and initial hydrogel volume of 11 {micro}L.

  5. Photopatterning of Hydrogel Microarrays in Closed Microchips.

    Science.gov (United States)

    Gumuscu, Burcu; Bomer, Johan G; van den Berg, Albert; Eijkel, Jan C T

    2015-12-14

    To date, optical lithography has been extensively used for in situ patterning of hydrogel structures in a scale range from hundreds of microns to a few millimeters. The two main limitations which prevent smaller feature sizes of hydrogel structures are (1) the upper glass layer of a microchip maintains a large spacing (typically 525 μm) between the photomask and hydrogel precursor, leading to diffraction of UV light at the edges of mask patterns, (2) diffusion of free radicals and monomers results in irregular polymerization near the illumination interface. In this work, we present a simple approach to enable the use of optical lithography to fabricate hydrogel arrays with a minimum feature size of 4 μm inside closed microchips. To achieve this, we combined two different techniques. First, the upper glass layer of the microchip was thinned by mechanical polishing to reduce the spacing between the photomask and hydrogel precursor, and thereby the diffraction of UV light at the edges of mask patterns. The polishing process reduces the upper layer thickness from ∼525 to ∼100 μm, and the mean surface roughness from 20 to 3 nm. Second, we developed an intermittent illumination technique consisting of short illumination periods followed by relatively longer dark periods, which decrease the diffusion of monomers. Combination of these two methods allows for fabrication of 0.4 × 10(6) sub-10 μm sized hydrogel patterns over large areas (cm(2)) with high reproducibility (∼98.5% patterning success). The patterning method is tested with two different types of photopolymerizing hydrogels: polyacrylamide and polyethylene glycol diacrylate. This method enables in situ fabrication of well-defined hydrogel patterns and presents a simple approach to fabricate 3-D hydrogel matrices for biomolecule separation, biosensing, tissue engineering, and immobilized protein microarray applications.

  6. The matrix reloaded: the evolution of regenerative hydrogels

    Directory of Open Access Journals (Sweden)

    Esmaiel Jabbari

    2016-05-01

    Full Text Available Cell-laden hydrogels can regenerate lost, damaged or malfunctioning tissues. Clinical success of such hydrogels is strongly dependent on the ability to tune their chemical, physico-mechanical, and biological properties to a specific application. In particular, mimicking the intricate arrangement of cell-interactive ligands of natural tissues is crucial to proper tissue function. Natural extracellular matrix elements represent a unique source for generating such interactions. A plethora of extracellular matrix-based approaches have been explored to augment the regenerative potential of hydrogels. These efforts include the development of matrix-like hydrogels, hydrogels containing matrix-like molecules, hydrogels containing decellularized matrix, hydrogels derived from decellularized matrix, and decellularized tissues as reimplantable matrix hydrogels. Here we review the evolution, strengths and weaknesses of these developments from the perspective of creating tissue regenerating hydrogels.

  7. Electrochemical Hydrogel Lithography of Calcium-Alginate Hydrogels for Cell Culture

    Directory of Open Access Journals (Sweden)

    Fumisato Ozawa

    2016-08-01

    Full Text Available Here we propose a novel electrochemical lithography methodology for fabricating calcium-alginate hydrogels having controlled shapes. We separated the chambers for Ca2+ production and gel formation with alginate with a semipermeable membrane. Ca2+ formed in the production chamber permeated through the membrane to fabricate a gel structure on the membrane in the gel formation chamber. When the calcium-alginate hydrogels were modified with collagen, HepG2 cells proliferated on the hydrogels. These results show that electrochemical hydrogel lithography is useful for cell culture.

  8. A review on polymeric hydrogel membranes for wound dressing applications: PVA-based hydrogel dressings

    Directory of Open Access Journals (Sweden)

    Elbadawy A. Kamoun

    2017-05-01

    Full Text Available This review presents the past and current efforts with a brief description on the featured properties of hydrogel membranes fabricated from biopolymers and synthetic ones for wound dressing applications. Many endeavors have been exerted during past ten years for developing new artificial polymeric membranes, which fulfill the demanded conditions for the treatment of skin wounds. This review mainly focuses on representing specifications of ideal polymeric wound dressing membranes, such as crosslinked hydrogels compatible with wound dressing purposes. But as the hydrogels with single component have low mechanical strength, recent trends have offered composite or hybrid hydrogel membranes to achieve the typical wound dressing requirements.

  9. Surface Wear Measurement Using Optical Correlation Technique

    Science.gov (United States)

    Acinger, Kresimir

    1983-12-01

    The coherent optical correlation technique was applied for measuring the surface wear of a tappet (part of car engine), worn by friction with the camshaft. It was found that maximum correlation intensity decays exponentially with the number of wear cycles (i.e. camshaft revolutions). Tappets of the same make have an identical rate of correlation decay. Tappets of different makes have different rates of correlation decay which are in agreement with observed long term wear.

  10. New approaches to atomic force microscope lithography on silicon

    DEFF Research Database (Denmark)

    Birkelund, Karen; Thomsen, Erik Vilain; Rasmussen, Jan Pihl

    1997-01-01

    We have investigated new approaches to the formation of conducting nanowires on crystalline silicon surfaces using atomic force microscope (AFM) lithography. To increase processing speed and reduce wear of the AFM tip, large-scale structures are formed with a direct laser write setup, while the AFM...

  11. Wear of hard materials by hard particles

    Energy Technology Data Exchange (ETDEWEB)

    Hawk, Jeffrey A.

    2003-10-01

    Hard materials, such as WC-Co, boron carbide, titanium diboride and composite carbide made up of Mo2C and WC, have been tested in abrasion and erosion conditions. These hard materials showed negligible wear in abrasion against SiC particles and erosion using Al2O3 particles. The WC-Co materials have the highest wear rate of these hard materials and a very different material removal mechanism. Wear mechanisms for these materials were different for each material with the overall wear rate controlled by binder composition and content and material grain size.

  12. Bio-inspired polymeric patterns with enhanced wear durability for microsystem applications

    Energy Technology Data Exchange (ETDEWEB)

    Singh, R. Arvind; Siyuan, L.; Satyanarayana, N. [Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117576 (Singapore); Kustandi, T.S. [Institute of Materials Research and Engineering, A-STAR, 3 Research Link, Singapore 117602 (Singapore); Sinha, Sujeet K., E-mail: mpesks@nus.edu.sg [Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117576 (Singapore)

    2011-10-10

    At micro/nano-scale, friction force dominates at the interface between bodies moving in relative motion and severely affects their smooth operation. This effect limits the performance of microsystem devices such as micro-electro-mechanical systems (MEMS). In addition, friction force also leads to material removal or wear and thereby reduces the durability i.e. the useful operating life of the devices. In this work, we fabricated bio-inspired polymeric patterns for tribological applications. Inspired by the surface features on lotus leaves namely, the protuberances and wax, SU-8 polymeric films spin-coated on silicon wafers were topographically and chemically modified. For topographical modification, micro-scale patterns were fabricated using nanoimprint lithography and for chemical modification, the micro-patterns were coated with perfluoropolyether nanolubricant. Tribological investigation of the bio-inspired patterns revealed that the friction coefficients reduced significantly and the wear durability increased by several orders. In order to enhance the wear durability much further, the micro-patterns were exposed to argon/oxygen plasma and were subsequently coated with the perfluoropolyether nanolubricant. Bio-inspired patterns with enhanced wear durability, such as the ones investigated in the current work, have potential tribological applications in MEMS/Bio-MEMS actuator-based devices. Highlights: {yields}Bio-inspired polymeric patterns for tribological applications in microsystems. {yields}Novel surface modification for the patterns to enhance tribological properties. {yields}Patterns show low friction properties and extremely high wear durability.

  13. Texturing of UHMWPE surface via NIL for low friction and wear properties

    Energy Technology Data Exchange (ETDEWEB)

    Kustandi, Tanu Suryadi; Low, Hong Yee [Institute of Materials Research and Engineering, 3 Research Link, Singapore 117602 (Singapore); Choo, Jian Huei; Sinha, Sujeet K, E-mail: hy-low@imre.a-star.edu.s, E-mail: mpesks@nus.edu.s [Department of Mechanical Engineering, National University of Singapore, 9 Engineering Drive 1, Singapore 117576 (Singapore)

    2010-01-13

    Wear is a major obstacle limiting the useful life of implanted ultra-high molecular weight polyethylene (UHMWPE) components in total joint arthroplasty. It has been a continuous effort in the implant industry to reduce the frictional wear problem of UHMWPE by improving the structure, morphology and mechanical properties of the polymer. In this paper, a new paradigm that utilizes nanoimprint lithography (NIL) in producing textures on the surface of UHMWPE is proposed to efficiently improve the tribological properties of the polymer. Friction and wear experiments were conducted on patterned and controlled (non-patterned) UHMWPE surfaces using a commercial tribometer, mounted with a silicon nitride ball, under a dry-sliding condition with normal loads ranging from 60 to 200 mN. It has been shown that the patterned UHMWPE surface showed a reduction in the coefficient of friction between 8% and 35% as compared with the controlled (non-patterned) surface, depending on the magnitude of the normal load. Reciprocating wear experiments also showed that the presence of surface textures on the polymer resulted in lower wear depth and width, with minimal material transfer to the sliding surface.

  14. Wear Characteristics of Multilayer-Coated Cutting Tools in Milling Wood and Wood-Based Composites

    Directory of Open Access Journals (Sweden)

    F. Fahrussiam

    2016-03-01

    Full Text Available This article presents the characteristic of wear on the clearance face of newly multilayer-coated K10 cutting tools when cutting mersawa wood, fiberboard, particleboard, and glass reinforced concrete (GRC. The K10 cutting tools were coated with monolayer titanium aluminum nitride (TiAlN, multilayer TiAlN/titanium silicon nitride (TiSiN, and TiAlN/titanium boron oxide nitride (TiBON. Cutting tests were performed on computer numeric control router at a high cutting speed of 17 m/s and a feed rate of 0.2 mm/rev to investigate the wear characteristics on the clearance face of these coated tools. Experimental results show that the coated tools experienced a smaller amount of clearance wear than the uncoated tool in cutting the mersawa wood, fiberboard, particleboard, and GRC. The GRC compared to the other work materials caused higher amount of clearance wear for both the uncoated and coated cutting tools. High content of silica and density were the reason for this phenomenon. The best coating among other coated cutting tools in this study was multilayer TiAlN/TiBON. The high hardness, low coefficient of friction, high resistance to oxidation, and high resistance to delamination wear of the multilayer-coated TiAlN/TiBON tool indicate a very promising applicability of this coating for high-speed cutting of abrasive woods and wood-based materials.

  15. Abrasive Wear Map of Polymer Tapes in Sand Dust Environment

    Institute of Scientific and Technical Information of China (English)

    WU Tong-hai; DIAO Dong-feng

    2006-01-01

    To make clear the wear conditions of ATM (Automatic Teller Machine) tribosystem when servicing in Chinese sand dust environment, abrasive wear of two kinds of polymer tapes specified for ATM, PI (Polyimide) and PEN (Polyethylene-2, 6-naphthalenedicarboxylate), was investigated in simulated sand dust environment with ATM tape-scraper tribosystem under various conditions of loads and sliding distances. The surface profiles of worn tape were measured with a surface profiler in order to calculating the wear cross-section areas and the wear volumes. The specific wear rates of polymer tapes were calculated under load conditions of 0.6, 1 and 1.5 N, and wear mechanisms were investigated with optical topography photos. As main results, the specific wear rates show stage variations in the wear process and the wear resistance of polymer tape shows good relationship with the mechanical deformation factors. In consideration of the service life, four wear models are generalized according to the magnitude of specific wear rates,which include no wear, mild wear, normal wear and severe wear model and the corresponding wear mechanisms for the four wear models are discussed with typical worn topographies. Based on the wear models and corresponding wear mechanisms, the abrasive wear maps of two polymer tapes servicing in sand dust environments are concluded for its industrial applications.

  16. Processing silk hydrogel and its applications in biomedical materials.

    Science.gov (United States)

    Wang, Hai-Yan; Zhang, Yu-Qing

    2015-01-01

    This review mainly introduces the types of silk hydrogels, their processing methods, and applications. There are various methods for hydrogel preparation, and many new processes are being developed for various applications. Silk hydrogels can be used in cartilage tissue engineering, drug release materials, 3D scaffolds for cells, and artificial skin, among other applications because of their porous structure and high porosity and the large surface area for growth, migration, adhesion and proliferation of cells that the hydrogels provide. All of these advantages have made silk hydrogels increasingly attractive. In addition, silk hydrogels have wide prospects for application in the field of biomedical materials.

  17. Tool flank wear model and parametric optimization in end milling of metal matrix composite using carbide tool: Response surface methodology approach

    Directory of Open Access Journals (Sweden)

    R. Arokiadass

    2012-04-01

    Full Text Available Highly automated CNC end milling machines in manufacturing industry requires reliable model for prediction of tool flank wear. This model later can be used to predict the tool flank wear (VBmax according to the process parameters. In this investigation an attempt was made to develop an empirical relationship to predict the tool flank wear (VBmax of carbide tools while machining LM25 Al/SiCp incorporating the process parameters such as spindle speed (N, feed rate (f, depth of cut (d and various % wt. of silicon carbide (S. Response surface methodology (RSM was applied to optimizing the end milling process parameters to attain the minimum tool flank wear. Predicted values obtained from the developed model and experimental results are compared, and error <5 percent is observed. In addition, it is concluded that the flank wear increases with the increase of SiCp percentage weight in the MMC.

  18. Structural transformations and wear resistance of abrasive-affected amorphous Fe- and Co-based alloys

    Science.gov (United States)

    Korshunov, L. G.; Chernenko, N. L.

    2008-12-01

    The abrasive wear resistance of the Fe64Co30Si3B3, Fe82.6Nb5Cu3Si8B1.4, Co86.5Cr4Si7B2.5, and Fe81Si4B13C2 amorphous alloys (ribbon 30 μm thick) has been investigated upon sliding over fixed abrasives (corundum and silicon carbide). The character of fracture of the surface and structural transformations initiated in these materials by the abrasive action have been studied by the metallographic, X-ray diffraction, and electron-microscopic methods. It has been shown that the abrasive wear resistance of the amorphous alloys is smaller by a factor of 1.6-2.9 than that of the Kh12M and U8 tool steels possessing approximately the same level of hardness. A pronounced softening of the surface layer of the amorphous alloys in the process of wear, which is characterized by a decrease in their microhardness reaching 12.5%, has been found. It has been shown that in the surface layer of these amorphous alloys upon wear there arises a small amount (on the order of several volume percent) of the nanocrystalline structure, which does not exert a marked effect on the microhardness and wear resistance of the alloys. In the alloys under study, the main factor that is responsible for their comparatively low abrasive wear resistance is their local softening in the process of wear caused by specific features of deformation processes occurring heterogeneously under the action of high shear contact stresses.

  19. Tribological Properties of Polyvinyl Alcohol Hydrogel Reinforced with Nanometer Hydroxy Apatite

    Institute of Scientific and Technical Information of China (English)

    WU Gang; ZHANG Wenguang; WANG Chengtao

    2008-01-01

    As a potential artificial cartilage material,the friction and wear properties of nano-hydroxy apatite(HA)particles filled poly(vinyl alcohol)hydrogel(PVA-H)composites sliding against stainless steel disk under water lubrication condition were studied by using a four bali tester.The worn surfaces were investigated by using a scanning electron microscope(SEM)to determine the wear mechanisms.Experimental results show that filling HA to PVA-H will slightly increase the friction coefficient of composites with the increasing of HA content under water lubrication condition.Meanwhile,HA particles can greatly reduce the wear mass loss of the PVA-H composites and enhance the load carrying capacity,the wear loss of the 1 wt% HA reinforced PVA-H composites can be decreased by 30 percent under 2.0 MPa to 50 percent under 0.5 MPa contact pressure.We also found that 2 wt% HA content of composites increase the wear mass loss under the same condition.SEM examination shows that the worn surface of low HA containing(1 wt%)composites are much smoother than that of pure PVA-H or high HA containing(2 wt%)composites under 1.5 MPa contact pressure.It is also found that there are big hole and big reunited HA particles in the surface of 2 wt% HA containing composites,which leads to deterioration of the surface of samples under higher loads in water lubrication.These results may be useful in the tribological design of artificial articular cartilage material.

  20. Temperature responsive hydrogel nanofibers and nanoparticles

    Science.gov (United States)

    Ruokolainen, Janne

    2011-03-01

    Poly(N-isopropylacrylamide) (PNIPAM) is one of the most extensively investigated synthetic temperature-responsive polymers. In this work temperature-responsive PNIPAM based triblock copolymer hydrogels, their self-assembly and phase behavior in bulk, are described. Additionally, recent results from responsive hydrogel nanofibers and hydrogel nanoparticles are shown. It is known that block copolymers form well-organized nano structures in bulk or thin films when annealed thermally or in solvent vapours. However, in the case of nanofibers or nanoparticles, the annealing leads in most cases to aggregation and particle sintering. This work utilizes aerosol-based gas phase method where the preparation and annealing of hydrogel nanoparticles with well-organized, hierarchical inner structures are performed without any particle coagulation or sintering. In the method, the block copolymers assemble within aerosol nanoparticles to form, for instance, lamellar onion-like or gyroid inner structures.

  1. Responsive polyelectrolyte hydrogels and soft matter micromanipulation

    NARCIS (Netherlands)

    Glazer, P.J.

    2013-01-01

    This dissertation describes experimental studies on the mechanisms underlying the dynamic response of polyelectrolyte hydrogels when submitted to an external electric potential. In addition, we explore the possibilities of miniaturization and manipulation of responsive gels and other soft matter sys

  2. Hydrogels made from chitosan and silver nitrate.

    Science.gov (United States)

    Kozicki, Marek; Kołodziejczyk, Marek; Szynkowska, Małgorzata; Pawlaczyk, Aleksandra; Leśniewska, Ewa; Matusiak, Aleksandra; Adamus, Agnieszka; Karolczak, Aleksandra

    2016-04-20

    This work describes a gelation of chitosan solution with silver nitrate. Above the critical concentration of chitosan (c*), continuous hydrogels of chitosan-silver can be formed. At lower concentrations, the formation of nano- and micro-hydrogels is discussed. The sol-gel analysis was performed to characterise the hydrogels' swelling properties. Moreover, the following were employed: (i) mechanical testing of hydrogels, (ii) inductively coupled plasma-optical emission spectroscopy (ICP-OES) for the measurement of silver concentration, (iii) scanning electron microscopy (SEM) to examine the morphology of products obtained, and (iv) dynamic light scattering (DLS) and UV-vis spectrophotometry to examine products formed at low concentration of chitosan (chydrogels were used for modification of cotton fabric in order to give it antimicrobial properties. The products obtained acted against Escherichia coli and Bacillus subtilis apart from the chitosan used that showed no such activity.

  3. Further development of a morphine hydrogel suppository.

    OpenAIRE

    Cole, L.; Hanning, C. D.; Robertson, S.; Quinn, K

    1990-01-01

    1. A sustained release monolithic morphine hydrogel suppository (MHS) was developed and administered to five volunteers. 2. The MHS delivered a mean of 55 mg morphine over 12 h. The mean plasma morphine concentration was 15 ng ml-1 from 2 to 12 h after administration. 3. Plasma morphine concentrations were comparable with those reported for the same dose given orally over the same time period. 4. The morphine hydrogel suppository appears to be an effective means of delivering morphine and may...

  4. Multitriggered Shape-Memory Acrylamide-DNA Hydrogels.

    Science.gov (United States)

    Lu, Chun-Hua; Guo, Weiwei; Hu, Yuwei; Qi, Xiu-Juan; Willner, Itamar

    2015-12-23

    Acrylamide-acrylamide nucleic acids are cross-linked by two cooperative functional motives to form shaped acrylamide-DNA hydrogels. One of the cross-linking motives responds to an external trigger, leading to the dissociation of one of the stimuli-responsive bridges, and to the transition of the stiff shaped hydrogels into soft shapeless states, where the residual bridging units, due to the chains entanglement, provide an intrinsic memory for the reshaping of the hydrogels. Subjecting the shapeless states to counter stimuli restores the dissociated bridges, and regenerates the original shape of the hydrogels. By the cyclic dissociation and reassembly of the stimuli-responsive bridges, the reversible switchable transitions of the hydrogels between stiff shaped hydrogel structures and soft shapeless states are demonstrated. Shaped hydrogels bridged by K(+)-stabilized G-quadruplexes/duplex units, by i-motif/duplex units, or by two different duplex bridges are described. The cyclic transitions of the hydrogels between shaped and shapeless states are stimulated, in the presence of appropriate triggers and counter triggers (K(+) ion/crown ether; pH = 5.0/8.0; fuel/antifuel strands). The shape-memory hydrogels are integrated into shaped two-hydrogel or three-hydrogel hybrid structures. The cyclic programmed transitions of selective domains of the hybrid structures between shaped hydrogel and shapeless states are demonstrated. The possible applications of the shape-memory hydrogels for sensing, inscription of information, and controlled release of loads are discussed.

  5. Enamel wear opposing polished and aged zirconia.

    Science.gov (United States)

    Burgess, J O; Janyavula, S; Lawson, N C; Lucas, T J; Cakir, D

    2014-01-01

    Aging of dental zirconia roughens its surface through low temperature degradation. We hypothesized that age-related roughening of zirconia crowns may cause detrimental wear to the enamel of an opposing tooth. To test our hypothesis, we subjected artificially aged zirconia and reference specimens to simulated mastication in a wear device and measured the wear of an opposing enamel cusp. Additionally, the roughness of the pretest surfaces was measured. The zirconia specimens, artificially aged by autoclave, showed no significant increase in roughness compared to the nonaged specimens. Furthermore, no significant difference in material or opposing enamel wear between the aged and nonaged zirconia was seen. All zirconia specimens showed less material and opposing enamel wear than the enamel to enamel control or veneering porcelain specimens. Scanning electron micrographs showed relatively smooth surfaces of aged and nonaged zirconia following wear testing. The micrographs of the veneering ceramic showed sharp fractured edges and fragments of wear debris. Zirconia may be considered a wear-friendly material for restorations opposing enamel, even after simulated aging.

  6. Numerical prediction of car tire wear

    NARCIS (Netherlands)

    Lupker, H.A.; Cheli, F.; Braghin, F.; Gelosa, E.; Keckman, A.

    2004-01-01

    Due to their many economic and ecological implications, the possibility to predict tire wear is of major importance to tire manufacturers, fleet owners and governments. Based on these observations, in 2000, a three-year project named TROWS (Tire and Road Wear and Slip assessment was started. One of

  7. Concrete ice abrasion rig and wear measurements

    NARCIS (Netherlands)

    Shamsutdinova, G.; Rike, P.B.; Hendriks, M.A.N.; Jacobsen, S.

    2015-01-01

    The wear of concrete material due to ice movement is a challenge for offshore and coastal structures. Concrete surfaces exposed to moving ice are subjected to wear at various rates depending on concrete and ice properties. At NTNU, Department of Structural Engineering, concrete ice abrasion phenomen

  8. Wear and microstructure in fine ceramic coatings

    Energy Technology Data Exchange (ETDEWEB)

    Vijande-Diaz, R.; Belzunce, J.; Fernandez, E. (ETS de Ingenieros Industriales, Area de Ingeneria Mecanica, Gijon (Spain)); Rincon, A.; Perez, M.C. (Inst. de Fisica-Quimica ' Roco Solano' , CSIC, Madrid (Spain))

    1991-08-15

    This paper presents a study of the wear resistance of two ceramic, plasma sprayed coatings of Al{sub 2}O{sub 3} and Cr{sub 2}O{sub 3}. Tests were carried out using an LWF-1 standard machine, with lineal contact, under dry friction, abrasion and lubricant conditions. The purpose of the tests were to study how load and speed affect material wear. Results show the lower wear rate of the ceramic coating compared with the steel one, as well as how remarkably load affects wear. On the other hand, however, considering the speed ranges used, wear resistance does not depend significantly on speed. The paper proves that the wear process follows Czichos' law. At the same time, reformulation of Archard's equation allows us to quantify wear using easily measurable factors such as pressure, speed, hardness, and those factors typically featuring this type of coatings, e.g. porosity. Also, a micrographic study of the coatings carried out by means of a scanning electron microscope has evidenced three stages in the wear mechanism: (a) plastic deformation of particles; (b) crack nucleation and propagation; and (c) loosening of ceramic particles. (orig.).

  9. Inhibition of erosive wear by fluoride varnish

    NARCIS (Netherlands)

    Vieira, A.; Jager, D. H. J.; Ruben, J. L.; Huysmans, M. C. D. N. J. M.

    2007-01-01

    It has been suggested that fluoride products with a protective mechanical component are advantageous in the prevention of erosive wear. The aim of this study was to evaluate in situ the effect of fluoride varnish (FV) in the prevention of wear due to erosion and combined erosion and toothbrush abras

  10. Concrete ice abrasion rig and wear measurements

    NARCIS (Netherlands)

    Shamsutdinova, G.; Rike, P.B.; Hendriks, M.A.N.; Jacobsen, S.

    2015-01-01

    The wear of concrete material due to ice movement is a challenge for offshore and coastal structures. Concrete surfaces exposed to moving ice are subjected to wear at various rates depending on concrete and ice properties. At NTNU, Department of Structural Engineering, concrete ice abrasion phenomen

  11. Friction and Wear Behaviors of Nanostructured Metals

    Institute of Scientific and Technical Information of China (English)

    Zhong HAN; Yusheng ZHANG; Ke LU

    2008-01-01

    Nanostructured (ns) materials, i.e., polycrystalline materials with grain sizes in the nanometer regime (typically below 100 nm), have drawn considerable attention in the past decades due to their unique properties such as high strength and hardness. Wear resistance of ns materials, one of the most important properties for engineering materials, has been extensively investigated in the past decades. Obvious differences have been identified in friction and wear behaviors Between the ns materials and their corresponding coarse-grained (cg) counterparts, consistently correlating with their unique structure characteristics and mechanical properties. On the other hand, the superior tribological properties of ns materials illustrate their potential applications under contact loads. The present overview will summarize the important progresses achieved on friction and wear behaviors of ns metallic materials, including ultrafine-grained (ufg) materials in recent years. Tribological properties and effects on friction and wear behaviors of ns materials will be discussed under different wear conditions including abrasive wear, sliding wear, and fretting wear. Their correlations with mechanical properties will be analyzed. Perspectives on development of this field will be highlighted as well.

  12. Inhibition of erosive wear by fluoride varnish

    NARCIS (Netherlands)

    Vieira, A.; Jager, D. H. J.; Ruben, J. L.; Huysmans, M. C. D. N. J. M.

    2007-01-01

    It has been suggested that fluoride products with a protective mechanical component are advantageous in the prevention of erosive wear. The aim of this study was to evaluate in situ the effect of fluoride varnish (FV) in the prevention of wear due to erosion and combined erosion and toothbrush

  13. Hydrogel: Preparation, characterization, and applications: A review

    Directory of Open Access Journals (Sweden)

    Enas M. Ahmed

    2015-03-01

    Full Text Available Hydrogel products constitute a group of polymeric materials, the hydrophilic structure of which renders them capable of holding large amounts of water in their three-dimensional networks. Extensive employment of these products in a number of industrial and environmental areas of application is considered to be of prime importance. As expected, natural hydrogels were gradually replaced by synthetic types due to their higher water absorption capacity, long service life, and wide varieties of raw chemical resources. Literature on this subject was found to be expanding, especially in the scientific areas of research. However, a number of publications and technical reports dealing with hydrogel products from the engineering points of view were examined to overview technological aspects covering this growing multidisciplinary field of research. The primary objective of this article is to review the literature concerning classification of hydrogels on different bases, physical and chemical characteristics of these products, and technical feasibility of their utilization. It also involved technologies adopted for hydrogel production together with process design implications, block diagrams, and optimized conditions of the preparation process. An innovated category of recent generations of hydrogel materials was also presented in some details.

  14. Fault Wear and Friction Evolution: Experimental Analysis

    Science.gov (United States)

    Boneh, Y.; Chang, J. C.; Lockner, D. A.; Reches, Z.

    2011-12-01

    Wear is an inevitable product of frictional sliding of brittle rocks as evidenced by the ubiquitous occurrence of fault gouge and slickenside striations. We present here experimental observations designed to demonstrate the relationship between wear and friction and their governing mechanisms. The experiments were conducted with a rotary shear apparatus on solid, ring-shaped rock samples that slipped for displacements up to tens of meters. Stresses, wear and temperature were continuously monitored. We analyzed 86 experiments of Kasota dolomite, Sierra White granite, Pennsylvania quartzite, Karoo gabbro, and Tennessee sandstone at slip velocities ranging from 0.002 to 0.97 m/s, and normal stress from 0.25 to 6.9 MPa. We conducted two types of runs: short slip experiments (slip distance mechanisms; and long slip experiments (slip distance > 3 m) designed to achieve mature wear conditions and to observe the evolution of wear and friction as the fault surfaces evolved. The experiments reveal three wear stages: initial, running-in, and steady-state. The initial stage is characterized by (1) discrete damage striations, the length of which is comparable to total slip , and local pits or plow features; (2) timing and magnitude of fault-normal dilation corresponds to transient changes of normal and shear stresses; and (3) surface roughness increasing with the applied normal stress. We interpret these observations as wear mechanisms of (a) plowing into the fresh rock surfaces; (b) asperity breakage; and (c) asperity climb. The running-in stage is characterized by (1) intense wear-rate over a critical wear distance of Rd = 0.3-2 m; (2) drop of friction coefficient over a weakening distance of Dc = 0.2-4 m; (3) Rd and Dc display positive, quasi-linear relation with each other. We interpret these observations as indicating the organizing of newly-created wear particles into a 'three-body' structure that acts to lubricate the fault (Reches & Lockner, 2010). The steady

  15. Biologically Based Restorative Management of Tooth Wear

    Directory of Open Access Journals (Sweden)

    Martin G. D. Kelleher

    2012-01-01

    Full Text Available The prevalence and severity of tooth wear is increasing in industrialised nations. Yet, there is no high-level evidence to support or refute any therapeutic intervention. In the absence of such evidence, many currently prevailing management strategies for tooth wear may be failing in their duty of care to first and foremost improve the oral health of patients with this disease. This paper promotes biologically sound approaches to the management of tooth wear on the basis of current best evidence of the aetiology and clinical features of this disease. The relative risks and benefits of the varying approaches to managing tooth wear are discussed with reference to long-term follow-up studies. Using reference to ethical standards such as “The Daughter Test”, this paper presents case reports of patients with moderate-to-severe levels of tooth wear managed in line with these biologically sound principles.

  16. Wear simulation effects on overdenture stud attachments.

    Science.gov (United States)

    Rutkunas, Vygandas; Mizutani, Hiroshi; Takahashi, Hidekazu; Iwasaki, Naohiko

    2011-01-01

    The aim of this study was to evaluate wear effects on overdenture resilient attachments. Six commercially available attachments were investigated: ERA orange and white (EO and EW), Locator pink, white and blue (LRP, LRW and LRB) and OP anchor (OP). Five specimens were used for wear simulation while other two specimens served as controls. Fifteen thousands insertion-removal cycles were simulated. Dimensional changes and surface characteristics were evaluated using light microscopy and SEM, respectively. Sudden decrease of retentive force was characteristic for EO and EW attachments. Retentive force of Locator attachments fluctuated throughout the wear simulation period. Dimensional changes and surface wear was more expressed on plastic cores than on plastic rings of attachment males. Based on SEM analysis, some of the specimens obtained smoother surface after wear simulation. Mechanism of retention loss of resilient overdenture attachments can be only partially explained by dimensional changes and surface alterations.

  17. Modeling wear of cast Ti alloys.

    Science.gov (United States)

    Chan, Kwai S; Koike, Marie; Okabe, Toru

    2007-05-01

    The wear behavior of Ti-based alloys was analyzed by considering the elastic-plastic fracture of individual alloys in response to the relevant contact stress field. Using the contact stresses as the process driving force, wear was computed as the wear rate or volume loss as a function of hardness and tensile ductility for Ti-based cast alloys containing an alpha, alpha+beta or beta microstructure with or without the intermetallic precipitates. Model predictions indicated that wear of Ti alloys increases with increasing hardness but with decreasing fracture toughness or tensile ductility. The theoretical results are compared with experimental data to elucidate the roles of microstructure in wear and contrasted against those in grindability.

  18. Assessment of variations in wear test methodology.

    Science.gov (United States)

    Gouvêa, Cresus V D; Weig, Karin; Filho, Thales R M; Barros, Renata N

    2010-01-01

    The properties of composite resin for dental fillings were improved by development, but its weakness continues to be its wear strength. Several tests have been proposed to evaluate wear in composite resin materials. The aim of this study was to verify how polishing and the type of abrasive can influence the wear rate of composite resin. The test was carried out on two groups. In one group we employed an ormocer and a hybrid composite that was polished group the composite was polished with the same abrasive paper plus a 1 microm and 0.25 microm grit diamond paste. A three-body wear test was performed using the metal sphere of the wear test machine, the composite and an abrasive. A diamond paste and aluminum oxide dispersion were used as abrasive. Analysis of the results showed that there was no difference between polishing techniques, but revealed a difference between abrasives.

  19. Dynamic SEM wear studies of tungsten carbide cermets. [friction and wear experiments

    Science.gov (United States)

    Brainard, W. A.; Buckley, D. H.

    1975-01-01

    Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined, and etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the tungsten carbide (WC) and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation, and the wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation, and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.

  20. Rigidity of silicone substrates controls cell spreading and stem cell differentiation

    Science.gov (United States)

    Vertelov, Grigory; Gutierrez, Edgar; Lee, Sin-Ae; Ronan, Edward; Groisman, Alex; Tkachenko, Eugene

    2016-09-01

    The dependences of spreading and differentiation of stem cells plated on hydrogel and silicone gel substrates on the rigidity and porosity of the substrates have recently been a subject of some controversy. In experiments on human mesenchymal stem cells plated on soft, medium rigidity, and hard silicone gels we show that harder gels are more osteogenic, softer gels are more adipogenic, and cell spreading areas increase with the silicone gel substrate rigidity. The results of our study indicate that substrate rigidity induces some universal cellular responses independently of the porosity or topography of the substrate.

  1. Asphalt wear and pollution transport

    Energy Technology Data Exchange (ETDEWEB)

    Lindgren, Asa [Division of Traffic Engineering, Lulea University of Technology Lulea (Sweden)

    1996-09-06

    Studded tires cause extensive wear of road surfaces during winter producing small particles. Besides transporting different adsorbed pollutants these particles also discharge metal ions by their own natural content. The major part (95%) of the asphalt is composed of stone fractions. The rest consists mainly of bitumen, which contains trace quantities of metals. Laboratory studies in this study have demonstrated different adsorbing properties of metal ions, as well as differences in adsorption when comparing stone materials. Two stone materials, a gabbro and a porphyry, have been tested for their adsorption properties concerning Pb, Cu, Zn and Cd. The gabbro showed better adsorption capacity than the porphyry. Gabbro has coarser grains, it is softer, and also has a higher content of most metals compared to the porphyry. In all tests lead and copper are more adsorbed than zinc and cadmium. All metal ions are released at about the same pH ({approx}4)

  2. AFM in peak force mode applied to worn siloxane-hydrogel contact lenses.

    Science.gov (United States)

    Abadías, Clara; Serés, Carme; Torrent-Burgués, Juan

    2015-04-01

    The objective of this work is to apply Atomic Force Microscopy in Peak Force mode to obtain topographic characteristics (mean roughness, root-mean-square roughness, skewness and kurtosis) and mechanical characteristics (adhesion, elastic modulus) of Siloxane-Hydrogel Soft Contact Lenses (CLs) of two different materials, Lotrafilcon B of Air Optix (AO) and Asmofilcon A of PremiO (P), after use (worn CLs). Thus, the results obtained with both materials will be compared, as well as the changes produced by the wear at a nanoscopic level. The results show significant changes in the topographic and mechanical characteristics of the CLs, at a nanoscopic level, due to wear. The AO CL show values of the topographic parameters lower than those of the P CL after wear, which correlates with a better comfort qualification given to the former by the wearers. A significant correlation has also been obtained between the adhesion values found after the use of the CLs with tear quality tests, both break-up-time and Schirmer.

  3. Synthesis and characterization of novel carboxymethylcellulose hydrogels and carboxymethylcellulolse-hydrogel-ZnO-nanocomposites.

    Science.gov (United States)

    Hashem, M; Sharaf, S; Abd El-Hady, M M; Hebeish, A

    2013-06-05

    New approach for preparation of CMC hydrogels was undertaken through reacting CMC with either malic, succinic or citric acid. Characteristics of the hydrogels, as monitored by the swelling behavior, FTIR, SEM, EDX, TEM and XRD were dependent on nature and concentration of the polycarboxylic acid, time and temperature of curing. The best practice achieved from these studies was harnessed to synthesize and characterize CMC hydrogel-ZnO-nanocomposites with additional study pertaining to the antibacterial activity of the nanocomposites. CMC hydrogel with excellent swelling behavior could be prepared by adding succinic acid (0.5%) to CMC solution then drying the obtained paste at 80 °C for 5 min followed by curing at 120 °C for 3 min. Similarly, addition of ZnNO3 solution to the CMC paste results in CMC hydrogel-ZnO-nanocomposites having biocidal activity to gram +ve and gram -ve bacteria.

  4. Energetic aspects of boring tools wear

    Directory of Open Access Journals (Sweden)

    Lazarová Edita

    2002-03-01

    Full Text Available In the process of rock desintegration a boring tool is subjected to the wear. From a viewpoint of the bit wear, changes on the contact of operating tool with rock at its one-shot and rerun load or overload by external forces are technically significant. Theis change results in the degradation of bit working properties and the output of desintegration also decreases. In the major part of cases, together with the bit wear, the contact area of a tool with a rock massifs enhanced and this fact causes an increase of fines (dust creation during the desintegration. The wear is always connected with a friction, forces action, deformation, damage, and the increased mechanical work consumption. As to energetic aspects of bit wear, the wear was observed as a function of bore length and in the most of cases as a dependence of the operating time. A linear dependence between the wear intensity (bit wear per unit of bore length and the specific energy of desintegration (energy consumed per volume unit of desintegrated rock was experimentally verified. Thus, the changes of bit wear can be implicitly observed by monitoring the specific energy. At the same time, the specific energy is a function of input parameters of the desintegration process and in the field of applicable external forces it shows an extreme (minimum. Therefore, the specific energy is useful for the extreme optimisation of the rock desintegration process from the viewpoint of the bit wear. It was mathematically proven that the tool output at the desintegration exponentially decreases with the amount of work consumed in the rock desintegration. The derivation of this knowledge comes out from the Krendelev equation.

  5. Adhesive Wear of Rollers in Vacuum

    Science.gov (United States)

    Shaeef, Iqbal; Krantz, Timothy L.

    2012-01-01

    This work was done to support NASA's James Webb Space Telescope that is equipped with a Near Infrared Camera and Spectrograph and Micro Shutter Assembly (MSA). A MSA mechanism's qualification test in cryogenic vacuum at 30deg K for 96K cycles resulted in roller wear and formation of some debris. Lab tests in vacuum were conducted at NASA Glenn Research Center (GRC) to understand the wear of Ti6Al4V mated with 440F steel rollers. Misalignment angle was found to have the most significant effect on debris formation. At misalignment angle of 1.4deg, significant amount of wear debris were formed within 50,000 cycles. Very few wear particles were found for a zero misalignment angle, and the total wear was small even after 367,000 cycles. The mode of wear in all the tests was attributed to adhesion, which was clearly evident from video records as well as the plate-like amalgamated debris material from both rollers. The adhesive wear rate was found to be approximately proportional to the misalignment angle. The wear is a two-way phenomenon, and the mixing of both roller materials in wear debris was confirmed by x-ray fluorescence (XRF) and EDX spectra. While there was a net loss of mass from the steel rollers, XRF and energy dispersive x-ray (EDX) spectra showed peaks of Ti on steel rollers, and peaks of Fe on Ti rollers. These results are useful for designers in terms of maintaining appropriate tolerances to avoid misalignment of rolling elements and the resulting severe wear

  6. A pH-sensitive Modified Polyacrylamide Hydrogel

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    A pH-sensitive modified polyacrylamide hydrogel was prepared by two steps and the modified polyacrylamide was characterized by 1HNMR spectrum. The surface morphology and swelling behavior of the hydrogels were investigated.

  7. New in situ crosslinking chemistries for hydrogelation

    Science.gov (United States)

    Roberts, Meredith Colleen

    Over the last half century, hydrogels have found immense value as biomaterials in a vast number of biomedical and pharmaceutical applications. One subset of hydrogels receiving increased attention is in situ forming gels. Gelling by either bioresponsive self-assembly or mixing of binary crosslinking systems, these technologies are useful in minimally invasive applications as well as drug delivery systems in which the sol-to-gel transition aids the formulation's performance. Thus far, the field of in situ crosslinking hydrogels has received limited attention in the development of new crosslinking chemistries. Moreover, not only does the chemical nature of the crosslinking moieties allow these systems to perform in situ, but they contribute dramatically to the mechanical properties of the hydrogel networks. For example, reversible crosslinks with finite lifetimes generate dynamic viscoelastic gels with time-dependent properties, whereas irreversible crosslinks form highly elastic networks. The aim of this dissertation is to explore two new covalent chemistries for their ability to crosslink hydrogels in situ under physiological conditions. First, reversible phenylboronate-salicylhydroxamate crosslinking was implemented in a binary, multivalent polymeric system. These gels formed rapidly and generated hydrogel networks with frequency-dependent dynamic rheological properties. Analysis of the composition-structure-property relationships of these hydrogels---specifically considering the effects of pH, degree of polymer functionality, charge of the polymer backbone and polymer concentration on dynamic theological properties---was performed. These gels demonstrate diverse mechanical properties, due to adjustments in the binding equilibrium of the pH-sensitive crosslinks, and thus have the potential to perform in a range of dynamic or bioresponsive applications. Second, irreversible catalyst-free "click" chemistry was employed in the hydrogelation of multivalent azide

  8. Influence of rotational speed during centrifugal casting on sliding wear behaviour of the Al-2Si alloy

    Institute of Scientific and Technical Information of China (English)

    P. G. MUKUNDA; A. SHAILESH RAO; Shrikantha S. RAO

    2009-01-01

    The microstructures and dry sliding wearbehaviour of an Al-2Si alloy cast centrifugally are studied. Results indicate that at optimum speed the cast has a microstructure consisting of uniformly distributed α-Al grains and fine eutectic silicon grains. The cast exhibited better wear resistance compared to the same cast prepared at different rpms. This paper attempts to investigate the influence of the microstructural changes in the Al-2Si alloy by varying the rotational speed of the mould and its combined action on the dry sliding wear behaviour.

  9. Three-dimensional nanocharacterization of porous hydrogel with ion and electron beams.

    Science.gov (United States)

    Al-Abboodi, Aswan; Fu, Jing; Doran, Pauline M; Chan, Peggy P Y

    2013-01-01

    Porous hydrogels provide an excellent environment for cell growth and tissue regeneration, with high permeability for oxygen, nutrients, and other water-soluble metabolites through their high water-content matrix. The ability to image three-dimensional (3D) cell growth is crucial for understanding and studying various cellular activities in 3D context, particularly for designing new tissue engineering scaffold, but it is still challenging to study cell-biomaterial interfaces with high resolution imaging. We demonstrate using focused ion beam (FIB) milling, electron imaging, and associated microanalysis techniques that novel 3D characterizations can be performed effectively on cells growing inside 3D hydrogel scaffold. With FIB-tomography, the porous microstructures were revealed at nanometer resolution, and the cells grown inside. The results provide a unique 3D measurement of hydrogel porosity, as compared with those from porosimetry, and offer crucial insights into material factors affecting cell proliferation at specific regions within the scaffold. We also proved that high throughput correlative imaging of cell growth is viable through a silicon membrane based environment. The proposed approaches, together with the protocols developed, provide a unique platform for analysis of the microstructures of novel biomaterials, and for exploration of their interactions with the cells as well.

  10. Preparation of bacterial cellulose based hydrogels and their viscoelastic behavior

    OpenAIRE

    2015-01-01

    Bacterial cellulose (BC) based hydrogels have been prepared in blended with carboxymethylcellulose and polyvinyl pyrrolidone by using heat treatment. The properties of BC-CMC and BC-PVP hydrogels were compared with pure BC, CMC and PVP hydrogels. These hydrogels were investigated by measuring their structural, morphological and viscoelastic properties. Through the morphological images, alignment of the porous flake like structures could be seen clearly within the inter-polymeric network of th...

  11. Gellan gum microgel-reinforced cell-laden gelatin hydrogels

    OpenAIRE

    Shin, Hyeongho; Olsen, Bradley D.; Khademhosseini, Ali

    2013-01-01

    The relatively weak mechanical properties of hydrogels remain a major drawback for their application as load-bearing tissue scaffolds. Previously, we developed cell-laden double-network (DN) hydrogels that were composed of photocrosslinkable gellan gum (GG) and gelatin. Further research into the materials as tissue scaffolds determined that the strength of the DN hydrogels decreased when they were prepared at cell-compatible conditions, and the encapsulated cells in the DN hydrogels did not f...

  12. Research on the printability of hydrogels in 3D bioprinting

    OpenAIRE

    Yong He; FeiFei Yang; HaiMing Zhao; Qing Gao; Bing Xia; JianZhong Fu

    2016-01-01

    As the biocompatible materials, hydrogels have been widely used in three- dimensional (3D) bioprinting/organ printing to load cell for tissue engineering. It is important to precisely control hydrogels deposition during printing the mimic organ structures. However, the printability of hydrogels about printing parameters is seldom addressed. In this paper, we systemically investigated the printability of hydrogels from printing lines (one dimensional, 1D structures) to printing lattices/films ...

  13. Experimental Study on Self-assembly of KLD-12 Peptide Hydrogel and 3-D Culture of MSC Encapsulated within Hydrogel In Vitro

    Institute of Scientific and Technical Information of China (English)

    Jianhua SUN; Qixin ZHENG

    2009-01-01

    o-fiber hydrogel in vitro. MSCs in KLD-12 peptide hydrogel grew well and proliferated with the culture time. KLD-12 peptide hydrogel can serve as an excellent injectable material of biological scaffolds in tissue engineering of IVD.

  14. A novel cellulose hydrogel prepared from its ionic liquid solution

    Institute of Scientific and Technical Information of China (English)

    LI Lu; LIN ZhangBi; YANG Xiao; WAN ZhenZhen; CUI ShuXun

    2009-01-01

    A novel cellulose hydrogel is prepared by regenerating cellulose from its ionic liquid solution. The transparency cellulose hydrogel presents a good chemical stability and an acceptable mechanical property. This non-toxic cellulose hydrogel should be biocompatibie and may be useful in the future as a biomaterial.

  15. Co-assembly of chitosan and phospholipids into hybrid hydrogels

    DEFF Research Database (Denmark)

    Mendes, Ana Carina Loureiro; Shekarforoush, Elhamalsadat; Engwer, Christoph

    2016-01-01

    Novel hybrid hydrogels were formed by adding chitosan (Ch) to phospholipids (P) self-assembled particles in lactic acid. The effect of the phospholipid concentration on the hydrogel properties was investigated and was observed to affect the rate of hydrogel formation and viscoelastic properties...

  16. Molecular dynamic simulations of the water absorbency of hydrogels.

    Science.gov (United States)

    Ou, Xiang; Han, Qiang; Dai, Hui-Hui; Wang, Jiong

    2015-09-01

    A polymer gel can imbibe solvent molecules through surface tension effect. When the solvent happens to be water, the gel can swell to a large extent and forms an aggregate called hydrogel. The large deformation caused by such swelling makes it difficult to study the behaviors of hydrogels. Currently, few molecular dynamic simulation works have been reported on the water absorbing mechanism of hydrogels. In this paper, we first use molecular dynamic simulation to study the water absorbing mechanism of hydrogels and propose a hydrogel-water interface model to study the water absorbency of the hydrogel surface. Also, the saturated water content and volume expansion rate of the hydrogel are investigated by building a hydrogel model with different cross-linking degree and by comparing the water absorption curves under different temperatures. The sample hydrogel model used consists of Polyethylene glycol diglycidyl ether (PEGDGE) as epoxy and the Jeffamine, poly-oxy-alkylene-amines, as curing agent. The conclusions obtained are useful for further investigation on PEGDGE/Jeffamine hydrogel. Moreover, the simulation methods, including hydrogel-water interface modeling, we first propose are also suitable to study the water absorbing mechanism of other hydrogels.

  17. A hydrogel-based enzyme-loaded polymersome reactor

    NARCIS (Netherlands)

    Hoog, de Hans-Peter; Arends, Isabel W.C.E.; Rowan, Alan E.; Cornelissen, Jeroen J.L.M.; Nolte, Roeland J.M.

    2010-01-01

    In this study we report the immobilization of enzyme-containing polymersomes into a macromolecular hydrogel. Whereas free enzyme shows progressive leakage from the hydrogel in a period of days, leakage of the polymersome-protected enzyme is virtually absent. The preparation of the hydrogel occurs un

  18. Hydrogels for an accommodating intraocular lens. An explorative study

    NARCIS (Netherlands)

    de Groot, JH; Spaans, CJ; van Calck, RV; van Beijma, FJ; Norrby, S; Pennings, AJ

    2003-01-01

    In this study it was investigated whether hydrogels could be used for an accommodating lens. The requirements of such a hydrogels are a low modulus, high refractive index, transparency, and strength. Since conventional hydrogels do not possess this combination of properties, a novel preparation meth

  19. A hydrogel-based enzyme-loaded polymersome reactor

    NARCIS (Netherlands)

    de Hoog, H.P.M.; de Hoog, Hans-Peter; Arends, Isabel W.C.E.; Rowan, Alan E.; Cornelissen, Jeroen Johannes Lambertus Maria; Nolte, Roeland J.M.

    2010-01-01

    In this study we report the immobilization of enzyme-containing polymersomes into a macromolecular hydrogel. Whereas free enzyme shows progressive leakage from the hydrogel in a period of days, leakage of the polymersome-protected enzyme is virtually absent. The preparation of the hydrogel occurs

  20. Wear Characteristics of Metallic Biomaterials: A Review

    Directory of Open Access Journals (Sweden)

    Mohamed A. Hussein

    2015-05-01

    Full Text Available Metals are extensively used in a variety of applications in the medical field for internal support and biological tissue replacements, such as joint replacements, dental roots, orthopedic fixation, and stents. The metals and alloys that are primarily used in biomedical applications are stainless steels, Co alloys, and Ti alloys. The service period of a metallic biomaterial is determined by its abrasion and wear resistance. A reduction in the wear resistance of the implant results in the release of incompatible metal ions into the body that loosen the implant. In addition, several reactions may occur because of the deposition of wear debris in tissue. Therefore, developing biomaterials with high wear resistance is critical to ensuring a long life for the biomaterial. The aim of this work is to review the current state of knowledge of the wear of metallic biomaterials and how wear is affected by the material properties and conditions in terms of the type of alloys developed and fabrication processes. We also present a brief evaluation of various experimental test techniques and wear characterization techniques that are used to determine the tribological performance of metallic biomaterials.

  1. Wear mechanism and wear prevention in coal-fueled diesel engines. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Schwalb, J.A.; Ryan, T.W.

    1991-10-01

    Coal fueled diesel engines present unique wear problems in the piston ring/cylinder liner area because of their tendency to contaminate the lube-oil with high concentrations of highly abrasive particles. This program involved a series of bench-scale wear tests and engine tests designed to investigate various aspects of the ring/liner wear problem and to make specific recommendations to engine manufacturers as to how to alleviate these problems. The program was organized into tasks, designed to accomplish the following objectives: (1) define the predominant wear mechanisms causing accelerated wear in the ring/liner area; (2) investigate the effectiveness of traditional approaches to wear prevention to prevent wear in coal-fueled engines; (3) further refine information on the most promising approaches to wear prevention; (4) present detailed information and recommendations to engine manufacturers on the most promising approach to wear prevention; (5) present a final report covering the entire program; (6)complete engine tests with a coal-derived liquid fuel, and investigate the effects of the fuel on engine wear and emissions.

  2. Wear mechanism and wear prevention in coal-fueled diesel engines

    Energy Technology Data Exchange (ETDEWEB)

    Schwalb, J.A.; Ryan, T.W.

    1991-10-01

    Coal fueled diesel engines present unique wear problems in the piston ring/cylinder liner area because of their tendency to contaminate the lube-oil with high concentrations of highly abrasive particles. This program involved a series of bench-scale wear tests and engine tests designed to investigate various aspects of the ring/liner wear problem and to make specific recommendations to engine manufacturers as to how to alleviate these problems. The program was organized into tasks, designed to accomplish the following objectives: (1) define the predominant wear mechanisms causing accelerated wear in the ring/liner area; (2) investigate the effectiveness of traditional approaches to wear prevention to prevent wear in coal-fueled engines; (3) further refine information on the most promising approaches to wear prevention; (4) present detailed information and recommendations to engine manufacturers on the most promising approach to wear prevention; (5) present a final report covering the entire program; (6)complete engine tests with a coal-derived liquid fuel, and investigate the effects of the fuel on engine wear and emissions.

  3. Dimensional Description of On-line Wear Debris Images for Wear Characterization

    Institute of Scientific and Technical Information of China (English)

    WU Tonghai; PENG Yeping; DU Ying; WANG Junqun

    2014-01-01

    As one of the most wear monitoring indicator, dimensional feature of individual particles has been studied mostly focusing on off-line analytical ferrograph. Recent development in on-line wear monitoring with wear debris images shows that merely wear debris concentration has been extracted from on-line ferrograph images. It remains a bottleneck of obtaining the dimension of on-line particles due to the low resolution, high contamination and particle’s chain pattern of an on-line image sample. In this work, statistical dimension of wear debris in on-line ferrograph images is investigated. A two-step procedure is proposed as follows. First, an on-line ferrograph image is decomposed into four component images with different frequencies. By doing this, the size of each component image is reduced by one fourth, which will increase the efficiency of subsequent processing. The low-frequency image is used for extracting the area of wear debris, and the high-frequency image is adopted for extracting contour. Second, a statistical equivalent circle dimension is constructed by equaling the overall wear debris in the image into equivalent circles referring to the extracted total area and premeter of overall wear debris. The equivalent circle dimension, reflecting the statistical dimension of larger wear debris in an on-line image, is verified by manual measurement. Consequently, two preliminary applications are carried out in gasoline engine bench tests of durability and running-in. Evidently, the equivalent circle dimension, together with the previously developed concentration index, index of particle coverage area (IPCA), show good performances in characterizing engine wear conditions. The proposed dimensional indicator provides a new statistical feature of on-line wear particles for on-line wear monitoring. The new dimensional feature conveys profound information about wear severity.

  4. Prediction of Wear in Crosslinked Polyethylene Unicompartmental Knee Arthroplasty

    Directory of Open Access Journals (Sweden)

    Jonathan Netter

    2015-05-01

    Full Text Available Wear-related complications remain a major issue after unicompartmental arthroplasty. We used a computational model to predict knee wear generated in vitro under diverse conditions. Inverse finite element analysis of 2 different total knee arthroplasty designs was used to determine wear factors of standard and highly crosslinked polyethylene by matching predicted wear rates to measured wear rates. The computed wear factor was used to predict wear in unicompartmental components. The articular surface design and kinematic conditions of the unicompartmental and tricompartmental designs were different. Predicted wear rate (1.77 mg/million cycles was very close to experimental wear rate (1.84 mg/million cycles after testing in an AMTI knee wear simulator. Finite element analysis can predict experimental wear and may reduce the cost and time of preclinical testing.

  5. Silicon Spintronics

    NARCIS (Netherlands)

    Jansen, R.

    2008-01-01

    Integration of magnetism and mainstream semiconductor electronics could impact information technology in ways beyond imagination. A pivotal step is implementation of spin-based electronic functionality in silicon devices. Remarkable progress made during the last two years gives confidence that this

  6. Experimental and numerical tribological studies of a boundary lubricant functionalized poro-viscoelastic PVA hydrogel in normal contact and sliding.

    Science.gov (United States)

    Blum, Michelle M; Ovaert, Timothy C

    2012-10-01

    -axial contact stress field was reduced to focus predominately on stress in the contact surface region in the direction of sliding. The results showed that during biphasic viscoelastic frictional sliding, the maximum tensile stress develops at the trailing edge of contact and a compressive stress develops at the leading edge in the direction of motion. The BLF-PVA hydrogels displayed a decrease in this tensile and compressive stress as compared to the standard PVA. The diminishment of these stresses would be expected to give the BLF-PVA hydrogels lower material wear with greater life expectancy as a synthetic articular cartilage implant.

  7. Prediction of wear rates in comminution equipment

    DEFF Research Database (Denmark)

    Jensen, Lucas Roald Dörig; Fundal, Erling; Møller, Per

    2010-01-01

    Raw material comminution equipment may be exposed to excessive wear, which makes it difficult to operate minerals processing plants continuously because lengthy and unplanned shut-downs interrupt the overall process. In general, most comminution equipment is fine-tuned to operate at low vibrations......-resistant high chromium white cast iron (21988/JN/HBW555XCr21), a heat-treated wear resistant steel (Hardox 400) and a plain carbon construction steel (S235). Quartz, which accounts for the largest wear loss in the cement industry, was chosen as abrasive. Other process parameters such as velocity (1–7 m...

  8. Internalization of Red Blood Cell-Mimicking Hydrogel Capsules with pH-Triggered Shape Responses

    Science.gov (United States)

    2015-01-01

    We report on naturally inspired hydrogel capsules with pH-induced transitions from discoids to oblate ellipsoids and their interactions with cells. We integrate characteristics of erythrocytes such as discoidal shape, hollow structure, and elasticity with reversible pH-responsiveness of poly(methacrylic acid) (PMAA) to design a new type of drug delivery carrier to be potentially triggered by chemical stimuli in the tumor lesion. The capsules are fabricated from cross-linked PMAA multilayers using sacrificial discoid silicon templates. The degree of capsule shape transition is controlled by the pH-tuned volume change, which in turn is regulated by the capsule wall composition. The (PMAA)15 capsules undergo a dramatic 24-fold volume change, while a moderate 2.3-fold volume variation is observed for more rigid PMAA–(poly(N-vinylpyrrolidone) (PMAA–PVPON)5 capsules when solution pH is varied between 7.4 and 4. Despite that both types of capsules exhibit discoid-to-oblate ellipsoid transitions, a 3-fold greater swelling in radial dimensions is found for one-component systems due to a greater degree of the circular face bulging. We also show that (PMAA–PVPON)5 discoidal capsules interact differently with J774A.1 macrophages, HMVEC endothelial cells, and 4T1 breast cancer cells. The discoidal capsules show 60% lower internalization as compared to spherical capsules. Finally, hydrogel capsules demonstrate a 2-fold decrease in size upon internalization. These capsules represent a unique example of elastic hydrogel discoids capable of pH-induced drastic and reversible variations in aspect ratios. Considering the RBC-mimicking shape, their dimensions, and their capability to undergo pH-triggered intracellular responses, the hydrogel capsules demonstrate considerable potential as novel carriers in shape-regulated transport and cellular uptake. PMID:24848786

  9. Hydrogel Actuation by Electric Field Driven Effects

    Science.gov (United States)

    Morales, Daniel Humphrey

    Hydrogels are networks of crosslinked, hydrophilic polymers capable of absorbing and releasing large amounts of water while maintaining their structural integrity. Polyelectrolyte hydrogels are a subset of hydrogels that contain ionizable moieties, which render the network sensitive to the pH and the ionic strength of the media and provide mobile counterions, which impart conductivity. These networks are part of a class of "smart" material systems that can sense and adjust their shape in response to the external environment. Hence, the ability to program and modulate hydrogel shape change has great potential for novel biomaterial and soft robotics applications. We utilized electric field driven effects to manipulate the interaction of ions within polyelectrolyte hydrogels in order to induce controlled deformation and patterning. Additionally, electric fields can be used to promote the interactions of separate gel networks, as modular components, and particle assemblies within gel networks to develop new types of soft composite systems. First, we present and analyze a walking gel actuator comprised of cationic and anionic gel legs attached by electric field-promoted polyion complexation. We characterize the electro-osmotic response of the hydrogels as a function of charge density and external salt concentration. The gel walkers achieve unidirectional motion on flat elastomer substrates and exemplify a simple way to move and manipulate soft matter devices in aqueous solutions. An 'ionoprinting' technique is presented with the capability to topographically structure and actuate hydrated gels in two and three dimensions by locally patterning ions induced by electric fields. The bound charges change the local mechanical properties of the gel to induce relief patterns and evoke localized stress, causing rapid folding in air. The ionically patterned hydrogels exhibit programmable temporal and spatial shape transitions which can be tuned by the duration and/or strength of

  10. Lithographically patterned silicon nanostructures on silicon substrates

    Energy Technology Data Exchange (ETDEWEB)

    Megouda, Nacera [Institut de Recherche Interdisciplinaire (IRI, USR 3078), Universite Lille1, Parc de la Haute Borne, 50 Avenue de Halley-BP 70478, 59658 Villeneuve d' Ascq and Institut d' Electronique, de Microelectronique et de Nanotechnologie (IEMN, CNRS-8520), Cite Scientifique, Avenue Poincare-B.P. 60069, 59652 Villeneuve d' Ascq (France); Faculte des Sciences, Universite Mouloud Mammeri, Tizi-Ouzou (Algeria); Unite de Developpement de la Technologie du Silicium (UDTS), 2 Bd. Frantz Fanon, B.P. 140 Alger-7 merveilles, Alger (Algeria); Piret, Gaeelle; Galopin, Elisabeth; Coffinier, Yannick [Institut de Recherche Interdisciplinaire (IRI, USR 3078), Universite Lille1, Parc de la Haute Borne, 50 Avenue de Halley-BP 70478, 59658 Villeneuve d' Ascq and Institut d' Electronique, de Microelectronique et de Nanotechnologie (IEMN, CNRS-8520), Cite Scientifique, Avenue Poincare-B.P. 60069, 59652 Villeneuve d' Ascq (France); Hadjersi, Toufik, E-mail: hadjersi@yahoo.com [Unite de Developpement de la Technologie du Silicium (UDTS), 2 Bd. Frantz Fanon, B.P. 140 Alger-7 merveilles, Alger (Algeria); Elkechai, Omar [Faculte des Sciences, Universite Mouloud Mammeri, Tizi-Ouzou (Algeria); and others

    2012-06-01

    The paper reports on controlled formation of silicon nanostructures patterns by the combination of optical lithography and metal-assisted chemical dissolution of crystalline silicon. First, a 20 nm-thick gold film was deposited onto hydrogen-terminated silicon substrate by thermal evaporation. Gold patterns (50 {mu}m Multiplication-Sign 50 {mu}m spaced by 20 {mu}m) were transferred onto the silicon wafer by means of photolithography. The etching process of crystalline silicon in HF/AgNO{sub 3} aqueous solution was studied as a function of the silicon resistivity, etching time and temperature. Controlled formation of silicon nanowire arrays in the unprotected areas was demonstrated for highly resistive silicon substrate, while silicon etching was observed on both gold protected and unprotected areas for moderately doped silicon. The resulting layers were characterized using scanning electron microscopy (SEM).

  11. Magnetic hyaluronate hydrogels: preparation and characterization

    Energy Technology Data Exchange (ETDEWEB)

    Tóth, Ildikó Y., E-mail: Ildiko.Toth@chem.u-szeged.hu; Veress, Gábor; Szekeres, Márta; Illés, Erzsébet; Tombácz, Etelka, E-mail: tombacz@chem.u-szeged.hu

    2015-04-15

    A novel soft way of hyaluronate (HyA) based magnetic hydrogel preparation was revealed. Magnetite nanoparticles (MNPs) were prepared by co-precipitation. Since the naked MNPs cannot be dispersed homogenously in HyA-gel, their surface was modified with natural and biocompatible chondroitin-sulfate-A (CSA) to obtain CSA-coated MNPs (CSA@MNPs). The aggregation state of MNPs and that loaded with increasing amount of CSA up to 1 mmol/g was measured by dynamic light scattering at pH~6. Only CSA@MNP with ≥0.2 mmol/g CSA content was suitable for magnetic HyA-gel preparation. Rheological studies showed that the presence of CSA@MNP with up to 2 g/L did not affect the hydrogel's rheological behavior significantly. The results suggest that the HyA-based magnetic hydrogels may be promising formulations for future biomedical applications, e.g. as intra-articular injections in the treatment of osteoarthritis. - Highlights: • Novel hyaluronate(HyA)-based biocompatible magnetic hydrogels were prepared. • Chondroitin-sulfate-A coating is needed to disperse magnetite particles in HyA-gel. • Rheological behavior of hydrogels was independent of the magnetite content (<2 g/L). • Gels remained in stable and homogeneously dispersed state even after 90 days storage. • Magnetic HyA-gels are promising candidates for use as intra-articular injection.

  12. The predictive analysis of wear work-rates in wear test rigs

    Energy Technology Data Exchange (ETDEWEB)

    Phalippou, C.; Delaune, X.

    1996-12-31

    Impact and sliding wear in components is classically studied, as far as the wear laws are concerned, in specific wear test rigs that simulate the vibratory motion induced by the flow. In this paper, an experimental and numerical study on the impact forces and wear work-rates of a typical AECL rig is presented. The mode shapes and frequencies are measured and compared with finite element computations. Impact and sliding motions between the wear specimens are calculated and compared to the experimental results. Impact forces, mean values of wear work-rates as well as the specimen relative motions are found to be close to the experimental data. (authors). 14 refs., 9 figs., 5 tabs.

  13. Poly(ethylene glycol) hydrogel microstructures encapsulating living cells

    Science.gov (United States)

    Koh, Won-Gun; Revzin, Alexander; Pishko, Michael V.

    2002-01-01

    We present an easy and effective method for the encapsulation of cells inside PEG-based hydrogel microstructures fabricated using photolithography. High-density arrays of three-dimensional microstructures were created on substrates using this method. Mammalian cells were encapsulated in cylindrical hydrogel microstructures of 600 and 50 micrometers in diameter or in cubic hydrogel structures in microfluidic channels. Reducing lateral dimension of the individual hydrogel microstructure to 50 micrometers allowed us to isolate 1-3 cells per microstructure. Viability assays demonstrated that cells remained viable inside these hydrogels after encapsulation for up to 7 days.

  14. Radiation synthesis and characterization of polyacrylic acid hydrogels

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    The pH-sensitive polyacrylic acid (PAA) hydrogels were synthesized by gamma-ray irradiation at an ambient temperature. The influences of dose, monomer concentration, cross-linking agent content, pH, and ionic strength on the swelling ratio (SR) of the PAA hydrogels were investigated in detail. The results show that the SR of the hydrogel decreases with an increase in the dose, monomer concentration, and cross-linking agent content. In alkaline solution, the SR of the hydrogels is much higher than that in acid solution. Also, the ionic strength can influence the SR of the hydrogels. The more the concentration, the lower the SR.

  15. Thermo-mechanical behavior of graphene oxide hydrogel

    Science.gov (United States)

    Ghosh, Rituparna; Deka Boruah, Buddha; Misra, Abha

    2017-02-01

    Graphene oxide hydrogel with encapsulated water presents a unique structural characteristic similar to open cell foam. It is demonstrated that the encapsulated water plays a vital role in tailoring compressive behavior of graphene oxide hydrogel under varying thermal conditions. The present study is focused on systematically evaluating both the temperature and frequency dependence on compressive behavior of hydrogel to elucidate the evolution of stiffness in a wider temperature range. The stiffness of the hydrogel is further tailored through encapsulation of nanoparticles to achieve an extraordinary enhancement in storage modulus. It is concluded that the change in phase of water provides a large gradient in the stiffness of the hydrogel.

  16. Macroporous hydrogels based on 2-hydroxyethyl methacrylate. Part III. Hydrogels as carriers for immobilization of proteins.

    Science.gov (United States)

    Michálek, J; Prádný, M; Artyukhov, A; Slouf, M; Smetana, K

    2005-08-01

    Four series of macroporous hydrogels based on crosslinked copolymers of 2-hydroxyethyl methacrylate (HEMA)-sodium methacrylate (MANa), copolymer HEMA-[2-(methacryloyloxy)ethyl]trimethylammonium chloride (MOETACl), terpolymer HEMA-MANa-MOETACl and on a polyelectrolyte complex were used as carriers for immobilization of proteins, chicken egg white albumin and avidin. The adsorption capacity of the hydrogels for the two proteins, kinetics and pH dependence of albumin adsorption and desorption were studied. The morphology of the hydrogels with and without immobilized albumin was studied by low-vacuum scanning electron microscopy.

  17. Wear mechanism and wear prevention in coal-fueled diesel engines

    Energy Technology Data Exchange (ETDEWEB)

    Schwalb, J.A.

    1991-06-01

    Contamination of the lube-oil with hard abrasive particles leads to a three-body abrasive wear mechanism that highly accelerates piston ring/cylinder liner wear in coal-fueled diesel engines. One approach to reducing that wear is to modify the size and orientation of surface asperities on the cylinder to enhance the formation of a hydrodynamic film, and to provide avenues of escape for particles that would otherwise be trapped in the wear zone. Another approach is to introduce additives into the contaminated lube-oil that further enhance hydrodynamic film formation, form chemical films on the wearing surfaces, or form films on the contaminant particles. This work focuses on defining the effects of cylinder liner surface finish, various configurations of slots in the cylinder liner surface, and various additives in the contaminated lube-oil on the wear process. Wear tests were initiated in a bench apparatus using coal-ash contaminated lube-oil to test the various wear configurations. The results of these tests indicate that the formation of a hydrodynamic film between the ring and cylinder specimens is enhanced by increasing surface roughness, and by orienting the surface asperities normal to the direction of ring travel but modifications to the cylinder liner surface did not greatly reduce the wear rate. Additives to the lubricant seemed to have a much more significant effect on wear, with a dispersant additive highly accelerating the wear, while a detergent additive was able to reduce the wear almost to the rate achieved where there was no contaminant.

  18. STUDIES ON TOOL WEAR CONDITION MONITORING

    Directory of Open Access Journals (Sweden)

    Hüseyin Metin ERTUNÇ

    2001-01-01

    Full Text Available In this study, wear mechanisms on cutting tools, especially for the drill bits, during the cutting operation have been investigated. As the importance of full automation in industry has gained substantial importance, tool wear condition monitoring during the cutting operation has been the subject of many investigators. Tool condition monitoring is very crucial in order to change the tool before breakage. Because tool breakage can cause considerable economical damage to both the machine tool and workpiece. In this paper, the studies on the monitoring of drill bit wear in literature have been introduced; the direct/indirect techniques used and sensor fusion techniques have been summarized. The methods which were proposed to determine tool wear evolution as processing the sensor signals collected have been provided and their references have been given for detailed information.

  19. Friction Properties of OTS SAMs and Silicon Surface under Water Lubrication

    Institute of Scientific and Technical Information of China (English)

    WANG Xin; ZHANG Xiangjun; AHMED Imad; LIU Ying; WEN Shizhu

    2009-01-01

    The friction and wear properties of silicon surface covered with octadecyltrichloro-silane (OTS) self-assembled monolayers (SAMs) were investigated by a UMT-2 microtribometer with and without water as lubricant, and then compared with that of bare silicon surface. Dry friction measurement results show that OTS SAMs have a very low friction coefficient compared to bare silicon surface under lower sliding velocity and normal contact load. However, heavy wear occurs on OTS SAMs under higher contact stress and sliding velocity. Under water lubrication, OTS SAMs can prevent wear obviously and meanwhile present low coefficient of friction even under high velocities.The improved frictional and anti-wear property on OTS SAMs surface is attributed to the hydrophobic property of OTS and hydrodynamic effect of water. Furthermore, a wear critical phase diagram for OTS SAMs with and without water was proposed, which indicates that OTS SAMs working under water lubrication owns a wider range of available load and velocity to reduce friction and prevent wear.

  20. Wear behavior of austenite containing plate steels

    Science.gov (United States)

    Hensley, Christina E.

    As a follow up to Wolfram's Master of Science thesis, samples from the prior work were further investigated. Samples from four steel alloys were selected for investigation, namely AR400F, 9260, Hadfield, and 301 Stainless steels. AR400F is martensitic while the Hadfield and 301 stainless steels are austenitic. The 9260 exhibited a variety of hardness levels and retained austenite contents, achieved by heat treatments, including quench and tempering (Q&T) and quench and partitioning (Q&P). Samples worn by three wear tests, namely Dry Sand/Rubber Wheel (DSRW), impeller tumbler impact abrasion, and Bond abrasion, were examined by optical profilometry. The wear behaviors observed in topography maps were compared to the same in scanning electron microscopy micrographs and both were used to characterize the wear surfaces. Optical profilometry showed that the scratching abrasion present on the wear surface transitioned to gouging abrasion as impact conditions increased (i.e. from DSRW to impeller to Bond abrasion). Optical profilometry roughness measurements were also compared to sample hardness as well as normalized volume loss (NVL) results for each of the three wear tests. The steels displayed a relationship between roughness measurements and observed wear rates for all three categories of wear testing. Nanoindentation was used to investigate local hardness changes adjacent to the wear surface. DSRW samples generally did not exhibit significant work hardening. The austenitic materials exhibited significant hardening under the high impact conditions of the Bond abrasion wear test. Hardening in the Q&P materials was less pronounced. The Q&T microstructures also demonstrated some hardening. Scratch testing was performed on samples at three different loads, as a more systematic approach to determining the scratching abrasion behavior. Wear rates and scratch hardness were calculated from scratch testing results. Certain similarities between wear behavior in scratch testing

  1. A Study of Slipper and Rail Wear Interaction at Low Speed

    Science.gov (United States)

    2014-06-19

    taking care of the boys, a house and a dog and for not getting discouraged. I pray that they will learn as I have how important it is to ensure Yahovah...wear, delamination wear, seizure wear, melt wear, severe oxidational wear and adhesive wear. Adhesive wear comprised of three zones: low speed...model is experiencing seizure or melt wear, then something is wrong with the model. Lim and Ashby also published on their wear map the normalized wear

  2. Dynamic Mechanical Analysis and Three-Body Abrasive Wear Behaviour of Thermoplastic Copolyester Elastomer Composites

    Directory of Open Access Journals (Sweden)

    Hemanth Rajashekaraiah

    2014-01-01

    Full Text Available Various amounts of short fibers (glass and carbon and particulate fillers like polytetrafluoroethylene (PTFE, silicon carbide (SiC, and alumina (Al2O3 were systematically introduced into the thermoplastic copolyester elastomer (TCE matrix for reinforcement purpose. The mechanical properties such as storage modulus, loss modulus, and Tan δ by dynamic mechanical analysis (DMA and three-body abrasive wear performance on a dry sand rubber wheel abrasion tester have been investigated. For abrasive wear study, the experiments were planned according to L27 orthogonal array by considering three factors and three levels. The complex moduli for TCE hybrid composites were pushed to a higher level relative to the TCE filled PTFE composite. At lower temperatures (in the glassy region, the storage modulus increases with increase in wt.% of reinforcement (fiber + fillers and the value is maximum for the composite with 40 wt.% reinforcement. The loss modulus and damping peaks were also found to be higher by the incorporation of SiC and Al2O3 microfillers. The routine abrasive wear test results indicated that TCE filled PTFE composite exhibited better abrasion resistance. Improvements in the abrasion resistance, however, have not been achieved by short-fiber and particlaute filler reinforcements. From the Taguchi’s experimental findings, optimal combination of control factors were obtained for minimum wear volume and also predictive correlations were proposed. Further, the worn surface morphology of the samples was discussed.

  3. Analysis of wear properties of aluminium based journal bearing alloys with and without lubrication.

    Science.gov (United States)

    Mathavan, J. Joy; Patnaik, Amar

    2016-09-01

    Apart from classical bearing materials, Aluminium alloys are used as bearing materials these days because of their superior quality. In this analysis, new Aluminium based bearing materials, with filler metals Si, Ni, and Cr are prepared by metal mould casting in burnout furnace machine, and tribological properties of these alloys with and without lubrication were tested. The experiments for wear with lubrication are conducted on multiple specimen tester and experiments without lubrication is conducted on Pin on disk tribometer. The disc material used was SAE 1050 steel. Wear tests were conducted at a sliding speed of 0.785 m/s and at a normal load of 20 N. Coefficient of friction values, temperature changes and wear of the specimens were plotted on graph according to the above mentioned working conditions. Hardness and weight losses of the specimens were calculated. The obtained results demonstrate how the friction and wear properties of these samples have changed with the % addition of Silicon, Chromium and Nickel to the base metal aluminium.

  4. Third abrasive wear mode: is it possible?

    Directory of Open Access Journals (Sweden)

    Ronaldo Câmara Cozza

    2014-04-01

    Full Text Available The objective of this paper is to propose an initial discussion on the characterization of a third abrasive wear mode. The results obtained in a previous work [1] under different test conditions revealed the occurrence of the superposition of the “rolling” and “grooving” abrasive wear modes. This phenomenon was denoted “micro-rolling abrasion” due to the observation that “rolling abrasion” was found to act on “grooving abrasion”.

  5. Biotribology :articular cartilage friction, wear, and lubrication

    OpenAIRE

    Schroeder, Matthew O

    1995-01-01

    This study developed, explored, and refined techniques for the in vitro study of cartilage-on-cartilage friction, deformation, and wear. Preliminary results of in vitro cartilage-on- cartilage experiments with emphasis on wear and biochemistry are presented. Cartilage-bone specimens were obtained from the stifle joints of steers from a separate controlled study. The load, sliding speed, and traverse of the lower specimens were held constant as lubricant and test length were varied. Lubric...

  6. Machining studies of die cast aluminum alloy-silicon carbide composites

    Science.gov (United States)

    Sornakumar, Thambu; Kathiresan, Marimuthu

    2010-10-01

    Metal matrix composites (MMCs) with high specific stiffness, high strength, improved wear resistance, and thermal properties are being increasingly used in advanced structural, aerospace, automotive, electronics, and wear applications. Aluminum alloy-silicon carbide composites were developed using a new combination of the vortex method and the pressure die-casting technique in the present work. Machining studies were conducted on the aluminum alloy-silicon carbide (SiC) composite work pieces using high speed steel (HSS) end-mill tools in a milling machine at different speeds and feeds. The quantitative studies on the machined work piece show that the surface finish is better for higher speeds and lower feeds. The surface roughness of the plain aluminum alloy is better than that of the aluminum alloy-silicon carbide composites. The studies on tool wear show that flank wear increases with speed and feed. The end-mill tool wear is higher on machining the aluminum alloy-silicon carbide composites than on machining the plain aluminum alloy.

  7. Wear Resistance Analysis of A359/SiC/20p Advanced Composite Joints Welded by Friction Stir Welding

    Directory of Open Access Journals (Sweden)

    O. Cuevas Mata

    Full Text Available Abstract Advancement in automotive part development demands new cost-effective materials with higher mechanical properties and improved wear resistance as compared to existing materials. For instance, Aluminum Matrix Composites (AMC shows improved mechanical properties as wear and abrasion resistance, high strength, chemical and dimensional stability. Automotive industry has focused in AMC for a variety of applications in automotive parts in order to improve the fuel economy, minimize vehicle emissions, improve design options, and increase the performance. Wear resistance is one of the most important factors in useful life of the automotive components, overall in those components submitted to mechanical systems like automotive brakes and suspensions. Friction Stir Welding (FSW rises as the most capable process to joining AMC, principally for the capacity to weld without compromising their ceramic reinforcement. The aim of this study is focused on the analysis of wear characteristics of the friction-stir welded joint of aluminum matrix reinforced with 20 percent in weight silicon carbide composite (A359/SiC/20p. The experimental procedure consisted in cut samples into small plates and perform three welds on these with a FSW machine using a tool with 20 mm shoulder diameter and 8 mm pin diameter. The wear features of the three welded joints and parent metal were analyzed at constant load applying 5 N and a rotational speed of 100 rpm employing a Pin-on - Disk wear testing apparatus, using a sapphire steel ball with 6 mm diameter. The experimental results indicate that the three welded joints had low friction coefficient compared with the parent metal. The results determine that the FSW process parameters affect the wear resistance of the welded joints owing to different microstructural modifications during welding that causes a low wear resistance on the welded zone.

  8. Hydrogels: a journey from diapers to gene delivery.

    Science.gov (United States)

    Chawla, Pooja; Srivastava, Alok Ranjan; Pandey, Priyanka; Chawla, Viney

    2014-02-01

    Hydrogels are the biomaterials comprising network of natural or synthetic polymers capable of absorbing large amount of water. Hydrogels are "Smart Gels" or "Intelligent Gels" which can be made to respond to the various environmental conditions like temperature, pH, magnetic/electric field, ionic strength, inflammation, external stress etc. There are numerous potential applications of hydrogels in modern day life ranging from a diaper to gene delivery. This review succinctly describes the classification, properties and preparation methods along with numerous diverse applications of hydrogels like agricultural hydrogels, hydrogel for drug delivery, sensing, dental adhesives, wound healing and tissue regeneration, diet aid and gastric retention and in tissue engineering etc. Hydrogels can be regarded as highly valuable biomaterials for human-beings.

  9. Commercialization of hydrogel for topical anesthesia by irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Nho, Youngchang; Kang, Philhyun; Lim, Younmook; Gwon, Huijeong; Park, Jongseok

    2013-09-15

    - The technologies to develop topical asesthetic hydrogels were developed and the preliminary clinical test was carried out for the prepared hydrogels at Kyunghee University. - The topical asesthetic hydrogels made by radiation are founded to have appropriate strengths and accelerant delivery behavior for lidocane which has a function of anesthetic. - New type of Hydrogels were designed in these experiments so that they had voids in hydrogels which led to much more absorption of exudate. - Several companies and Philippine Nuclear Research Institute(PNRI) are interested in our technologies to produce the hydrogels, we signed a MOA to support PNRI technically in the field of hydrogels and perform the general technical cooperation between Advanced Radiation Technology and PNRI.

  10. pH-Sensitive Hydrogel for Micro-Fluidic Valve

    Directory of Open Access Journals (Sweden)

    Zhengzhi Yang

    2012-07-01

    Full Text Available The deformation behavior of a pH-sensitive hydrogel micro-fluidic valve system is investigated using inhomogeneous gel deformation theory, in which the fluid-structure interaction (FSI of the gel solid and fluid flow in the pipe is considered. We use a finite element method with a well adopted hydrogel constitutive equation, which is coded in commercial software, ABAQUS, to simulate the hydrogel valve swelling deformation, while FLUENT is adopted to model the fluid flow in the pipe of the hydrogel valve system. The study demonstrates that FSI significantly affects the gel swelling deformed shapes, fluid flow pressure and velocity patterns. FSI has to be considered in the study on fluid flow regulated by hydrogel microfluidic valve. The study provides a more accurate and adoptable model for future design of new pH-sensitive hydrogel valves, and also gives a useful guideline for further studies on hydrogel fluidic applications.

  11. Radiation processed hydrogel of poly (vinyl alcohol) with biodegradable polysaccharides.

    Science.gov (United States)

    Chowdhury, M N K; Alam, A K M M; Dafader, N C; Haque, M E; Akhtar, F; Ahmed, M U; Rashid, H; Begum, R

    2006-01-01

    Poly(vinyl alcohol) (PVA) can be modified to polymer hydrogels by radiation crosslinking and can be used in different biomedical applications. A study was done on the optimization of ingredients concentration for preparing good quality PVA hydrogels with natural polysaccharides. The synthesized hydrogels were also characterized by measuring the different physical properties e.g. gel fraction, swelling and absorption rate. Besides these, sterility test were also performed. Good quality hydrogels were obtained from PVA and natural polysaccharides solutions with 27 kGy radiation dose. There is an influence of natural polysaccharides on the gel fraction of hydrogel. The increase in the amount of polysaccharide causes a decrease in gel fraction that is decrease in the crosslinking density of PVA hydrogel network. The prepared hydrogels were found to be sterile.

  12. Thermoresponsive chitosan-agarose hydrogel for skin regeneration.

    Science.gov (United States)

    Miguel, Sónia P; Ribeiro, Maximiano P; Brancal, Hugo; Coutinho, Paula; Correia, Ilídio J

    2014-10-13

    Healing enhancement and pain control are critical issues on wound management. So far, different wound dressings have been developed. Among them, hydrogels are the most applied. Herein, a thermoresponsive hydrogel was produced using chitosan (deacetylation degree 95%) and agarose. Hydrogel bactericidal activity, biocompatibility, morphology, porosity and wettability were characterized by confocal microscopy, MTS assay and SEM. The performance of the hydrogel in the wound healing process was evaluated through in vivo assays, during 21 days. The attained results revealed that hydrogel has a pore size (90-400 μm) compatible with cellular internalization and proliferation. A bactericidal activity was observed for hydrogels containing more than 188 μg/mL of chitosan. The improved healing and the lack of a reactive or a granulomatous inflammatory reaction in skin lesions treated with hydrogel demonstrate its suitability to be used in a near future as a wound dressing.

  13. Antimicrobial hydrogels for the treatment of infection.

    Science.gov (United States)

    Veiga, Ana Salomé; Schneider, Joel P

    2013-11-01

    The increasing prevalence of microbial infections, especially those associated with impaired wound healing and biomedical implant failure has spurred the development of new materials having antimicrobial activity. Hydrogels are a class of highly hydrated material finding use in diverse medical applications such as drug delivery, tissue engineering, as wound fillers, and as implant coatings, to name a few. The biocompatible nature of many gels make them a convenient starting platform to develop selectively active antimicrobial materials. Hydrogels with antimicrobial properties can be obtained through the encapsulation or covalent immobilization of known antimicrobial agents, or the material itself can be designed to possess inherent antimicrobial activity. In this review we present an overview of antimicrobial hydrogels that have recently been developed and when possible provide a discussion relevant to their mechanism of action.

  14. Controlled Angiogenesis in Peptide Nanofiber Composite Hydrogels.

    Science.gov (United States)

    Wickremasinghe, Navindee C; Kumar, Vivek A; Shi, Siyu; Hartgerink, Jeffrey D

    2015-09-14

    Multidomain peptide (MDP) nanofibers create scaffolds that can present bioactive cues to promote biological responses. Orthogonal self-assembly of MDPs and growth-factor-loaded liposomes generate supramolecular composite hydrogels. These composites can act as delivery vehicles with time-controlled release. Here we examine the controlled release of placental growth factor-1 (PlGF-1) for its ability to induce angiogenic responses. PlGF-1 was loaded either in MDP matrices or within liposomes bound inside MDP matrices. Scaffolds showed expected rapid infiltration of macrophages. When released through liposomes incorporated in MDP gels (MDP(Lipo)), PlGF-1 modulates HUVEC VEGF receptor activation in vitro and robust vessel formation in vivo. These loaded MDP(Lipo) hydrogels induce a high level of growth-factor-mediated neovascular maturity. MDP(Lipo) hydrogels offer a biocompatible and injectable platform to tailor drug delivery and treat ischemic tissue diseases.

  15. Synthesis and characterization of anisotropic magnetic hydrogels

    Science.gov (United States)

    Hinrichs, Stephan; Nun, Nils; Fischer, Birgit

    2017-06-01

    Multiresponsive hydrogels are an interesting new class of materials. They offer the advantage, that they respond to different stimuli like temperature, pH and magnetic fields. By this they can change their properties which makes the hydrogels ideal candidates for many applications in the technical as well as medical field. Here we present the synthesis and characterization of hydrogels - micro- as well as macrogels - which consist of an iron oxide core, varying in phase and morphology, embedded in a thermoresponsive polymer, consisting of poly N-isopropylacrylamide. By using dynamic light scattering we investigated the thermoresponsive properties. In addition we were able to follow the formation of the macrogel by monitoring the shear viscosity.

  16. A simple method to control nanotribology behaviors of monocrystalline silicon

    Science.gov (United States)

    Wang, X. D.; Guo, J.; Chen, C.; Chen, L.; Qian, L. M.

    2016-01-01

    A simple method was proposed to control the nanotribology behaviors of monocrystalline silicon against SiO2 microsphere by adjusting relative humidity (RH). Experimental results indicated that adhesion work, friction coefficient, and nanowear of silicon against SiO2 microsphere significantly varied between 60% and 90% RH. Under 60% RH, adhesion work was 119 mN/m, and friction coefficient was about 0.53. However, adhesion work and friction coefficient decreased to ˜70 mN/m and ˜0.3 under 90% RH, respectively. An apparent wear track ˜13 nm deep formed on the silicon surface under 60% RH, whereas no obvious wear scar was observed on the silicon surface under 90% RH. Analysis indicated that such tribological behaviors were due to different water condensations on the silicon surface under 60% and 90% RH. Under 60% RH, the water that condensed on the surfaces of the silicon sample and SiO2 tip mainly consisted of ice-like water. As a result, adhesion work was enlarged by the breaking force of the ice-like water bridge in the contact area. Given that a ≡Si-O-Si≡ bonding bridge easily formed between the silicon surface and the SiO2 tip with the help of water condensation under 60% RH instead of 90% RH, the friction coefficient was large and the nanowear of the silicon sample was severe under 60% RH. These results may help elucidate the nanotribology behaviors of silicon and facilitate the tribological design of dynamic microelectromechanical systems working under humid conditions.

  17. Pseudomembranous candidiasis in patient wearing full denture

    Directory of Open Access Journals (Sweden)

    Nurdiana Nurdiana

    2009-06-01

    Full Text Available Background: Oral candidiasis is a common opportunistic infection of the oral cavity caused by an overgrowth of Candida species, the commonest being Candida albicans. Candida albicans is a harmless commensal organism inhabiting the mouths but it can change into pathogen and invade tissue and cause acute and chronic disease. Dentures predispose to infection with Candida in as many as 65% of elderly people wearing full upper dentures. Purpose: The purpose of this case report is to discuss thrush in patient wearing full denture which rapidly developed. Case: This paper report a case of 57 year-old man who came to the Oral Medicine Clinic Faculty of Dentistry Airlangga University with clinical appearance of pseudomembranous candidiasis (thrush. Case Management: Diagnosis of this case is confirmed with microbiology examination. Patient was wearing full upper dentures, and from anamnesis known that patient wearing denture for 24 hours and he had poor oral hygiene. Patient was treated with topical (nystatin oral suspension and miconazole oral gel and systemic (ketoconazole antifungal. Patient also instructed not to wear his denture and cleaned white pseudomembrane on his mouth with soft toothbrush. Conclusion: Denture, habit of wearing denture for 24 hours, and poor oral hygiene are predisposing factors of thrush and it can healed completely after treated with topical and systemic antifungal.

  18. Injectable silk-polyethylene glycol hydrogels.

    Science.gov (United States)

    Wang, Xiaoqin; Partlow, Benjamin; Liu, Jian; Zheng, Zhaozhu; Su, Bo; Wang, Yansong; Kaplan, David L

    2015-01-01

    Silk hydrogels for tissue repair are usually pre-formed via chemical or physical treatments from silk solutions. For many medical applications, it is desirable to utilize injectable silk hydrogels at high concentrations (>8%) to avoid surgical implantation and to achieve slow in vivo degradation of the gel. In the present study, injectable silk solutions that formed hydrogels in situ were generated by mixing silk with low-molecular-weight polyethylene glycol (PEG), especially PEG300 and 400 (molecular weight 300 and 400g mol(-1)). Gelation time was dependent on the concentration and molecular weight of PEG. When the concentration of PEG in the gel reached 40-45%, gelation time was less than 30min, as revealed by measurements of optical density and rheological studies, with kinetics of PEG400 faster than PEG300. Gelation was accompanied by structural changes in silk, leading to the conversion from random coil in solution to crystalline β-sheets in the gels, based on circular dichroism, attenuated total reflection Fourier transform infrared spectroscopy and X-ray diffraction. The modulus (127.5kPa) and yield strength (11.5kPa) determined were comparable to those of sonication-induced hydrogels at the same concentrations of silk. The time-dependent injectability of 15% PEG-silk hydrogel through 27G needles showed a gradual increase of compression forces from ∼10 to 50N within 60min. The growth of human mesenchymal stem cells on the PEG-silk hydrogels was hindered, likely due to the presence of PEG, which grew after a 5 day delay, presumably while the PEG solubilized away from the gel. When 5% PEG-silk hydrogel was subcutaneously injected in rats, significant degradation and tissue in-growth took place after 20 days, as revealed by ultrasound imaging and histological analysis. No significant inflammation around the gel was observed. The features of injectability, slow degradation and low initial cell attachment suggests that these PEG-silk hydrogels are of interest

  19. Application of hydrogel system for neutron attenuation

    CERN Document Server

    Gupta, S C; Gupta, B P

    2000-01-01

    Hydrogel sheets based on poly(vinyl alcohol) (PVA) and poly(vinyl acetate) (PVAc) have been prepared by the technique of acetalization of PVA using formaldehyde and grafting of acrylic acid onto PVAc by gamma irradiation. PVA hydrogel (PVAB) sheets have been prepared in geometrically stable shapes by compression moulding process and characterised for their thermal properties, geometrical stability on water absorption, and neutron shielding efficiency. The effective protection from fast neutrons can be increased by a factor of 18% by swelling the PVAB sheets to 210% in water. The water intake and subsequent retention of water by the sheet can be tailored as per shielding requirements.

  20. High Strength and Wear Resistant Aluminum Alloy for High Temperature Applications

    Science.gov (United States)

    Lee, Jonathan A.; Munafo, Paul M. (Technical Monitor)

    2002-01-01

    In this paper, a new high strength and wear resistant aluminum cast alloy invented by NASA-MSFC for high temperature applications will be presented. Developed to meet U.S. automotive legislation requiring low-exhaust emission, the novel NASA 398 aluminum-silicon alloy offers dramatic improvement in tensile and fatigue strengths at elevated temperatures (500 F-800 F), enabling new pistons to utilize less material, which can lead to reducing part weight and cost as well as improving performance. NASA 398 alloy also offers greater wear resistance, surface hardness, dimensional stability, and lower thermal expansion compared to conventional aluminum alloys for several commercial and automotive applications. The new alloy can be produced economically using permanent steel molds from conventional gravity casting or sand casting. The technology was developed to stimulate the development of commercial aluminum casting products from NASA-developed technology by offering companies the opportunity to license this technology.

  1. Chemically robust carbon nanotube – PTFE superhydrophobic thin films with enhanced ability of wear resistance

    Directory of Open Access Journals (Sweden)

    Kewei Wang

    2017-06-01

    Full Text Available A chemically robust superhydrophobic nanocomposite thin film with enhanced wear resistance is prepared from a composite comprising polytetrafluoroethylene (PTFE and carbon nanotubes. The superhydrophobic thin films with hierarchical structure are fabricated by spraying an environmentally friendly aqueous dispersion containing carbon nanotubes and PTFE resin on silicon wafer. Thin films with a contact angle of 154.1°±2° and a sliding angle less than 2° remain superhydrophobic after abrading over 500 times under a pressure of 50 g/cm2. The thin film is also extremely stable even under much stress conditions. To further the understanding of the enhancement of wear resistance, we investigated the formation of microsized structure and their effects. The growth of microbumps is caused by attracting solution droplet to the hydrophilic islands on hydrophobic surface.

  2. Wear Property of Cast Steel Wheel Material in Rail Truck

    Institute of Scientific and Technical Information of China (English)

    MI Guo-fa; LIU Yan-lei; ZHANG Bin; FU Xiu-qin; ZHANG Hong; SONG Guo-xiang

    2009-01-01

    Wear property of material plays a key role in the service time of workpiece.A major objective in the development of new wheel materials is to improve the wear performance.The wear property of B and B+ grade cast steel materials was reported.The results showed that B+ grade cast steel material exhibited better wear property than the B grade material.Carbon content related to the hardness match was the principal factor affecting the wear properties.

  3. Wear-resistance of Aluminum Matrix Microcomposite Materials

    Directory of Open Access Journals (Sweden)

    M. Kandeva

    2011-03-01

    Full Text Available A procedure is developed for the study of wear of aluminum alloys AlSi7 obtained by casting, reinforced by TiC microparticles, before and after heat treatment. Tribological study is realized under conditions of friction on counterbody with fixed abrasive. Experimental results were obtained for mass wear, wear rate, wear intensity and wear-resistance of the alloys with different wt% of microparticles.

  4. The synthesis of hydrogels with controlled distribution of polymer brushes in hydrogel network

    Energy Technology Data Exchange (ETDEWEB)

    Sun, YuWei; Zhou, Chao; Zhang, AoKai; Xu, LiQun; Yao, Fang [School of Chemistry and Chemical Engineering, Southeast University, Jiangning District, Nanjing, Jiangsu Province, 211189 (China); Cen, Lian, E-mail: cenlian@hotmail.com [National Tissue Engineering Center of China, No.68, East Jiang Chuan Road, Shanghai, 200241 (China); School of Chemical Engineering, East China University of Science and Technology, No.130, Mei Long Road, Shanghai, 200237 (China); Fu, Guo-Dong, E-mail: fu7352@seu.edu.cn [School of Chemistry and Chemical Engineering, Southeast University, Jiangning District, Nanjing, Jiangsu Province, 211189 (China)

    2014-11-30

    Highlights: • Many biological tissues are 3-dimensionally asymmetric in structure and properties, it would be desirable if hydrogels could bear such structural similarity with specialized surface and bulk properties. Moreover, gradual but continuous variation in spatial structural and property is also a common phenomenon in biological tissues, such as interfaces between bone and tendon, or between bone and cartilage. Hence, the development of a method to introduce well-defined functional polymer brushes on PEG hydrogels, especially with precisely controlled spatial structure in 3-dimensions, would impart the hydrogels with special functionalities and wider applications. Poly(ethylene glycol) (PEG) hydrogels with 3-dimensionally controlled well-defined poly(N-isopropylacrylamide) (poly(NIPAAm)) brushes were prepared by combined copper(I)-catalyzed azide-alkyne cycloaddition (“Click Chemistry”) and atom transfer radical polymerization (ATRP). The resulting hydrogels were presented as representatives with their detailed synthesis routes and characterization. H{sub PEG}-S-poly(NIPAAm) is a hydrogel with poly(NIPAAm) brushes mainly grafted on surface, whereas H{sub PEG}-G-poly(NIPAAm) has a gradiently decreased poly(NIPAAm) brushes in their chain length from surface to inside. On the other hand, poly(NIPAAm) brushes in H{sub PEG}-U-poly(NIPAAm) are uniformly dispersed throughout the whole hydrogel network. Successful preparation of H{sub PEG}-S-poly(NIPAAm), H{sub PEG}-G-poly(NIPAAm) and H{sub PEG}-U-poly(NIPAAm) were ascertained by X-ray photoelectron spectroscopy (XPS) and water contact angle measurement. Hence, the flexibility and controllability of the synthetic strategy in varying the distribution of polymer brushes and hydrogel surface properties was demonstrated. Hydrogels with tunable and well-defined 3-dimensional poly(NIPAAm) polymer brushes could be tailor-designed to find potential applications in smart devices or skin dressing, such as for diabetics

  5. In vivo remineralization of dentin using an agarose hydrogel biomimetic mineralization system

    Science.gov (United States)

    Han, Min; Li, Quan-Li; Cao, Ying; Fang, Hui; Xia, Rong; Zhang, Zhi-Hong

    2017-02-01

    A novel agarose hydrogel biomimetic mineralization system loaded with calcium and phosphate was used to remineralize dentin and induce the oriented densely parallel packed HA layer on defective dentin surface in vivo in a rabbit model. Firstly, the enamel of the labial surface of rabbits’ incisor was removed and the dentin was exposed to oral environment. Secondly, the hydrogel biomimetic mineralization system was applied to the exposed dentin surface by using a custom tray. Finally, the teeth were extracted and evaluated by scanning electron microscopy, X-ray diffraction, and nanoindentation test after a certain time of mineralization intervals. The regenerated tissue on the dentin surface was composed of highly organised HA crystals. Densely packed along the c axis, these newly precipitated HA crystals were perpendicular to the underlying dental surface with a tight bond. The demineralized dentin was remineralized and dentinal tubules were occluded by the grown HA crystals. The nanohardness and elastic modulus of the regenerated tissue were similar to natural dentin. The results indicated a potential clinical use for repairing dentin-exposed related diseases, such as erosion, wear, and dentin hypersensitivity.

  6. The effect of tinted soft contact lens wear on functional visual acuity and higher-order aberrations.

    Science.gov (United States)

    Watanabe, Kazuhiro; Kaido, Minako; Ishida, Reiko; Dogru, Murat; Negishi, Kazuno; Tsubota, Kazuo

    2014-06-01

    To investigate the differences of functional visual acuity (FVA) and high order aberrations (HOAs) in relation to tinted and clear hydrogel soft contact lens (SCL) wear. A prospective comparative study was performed in 16 eyes of 16 healthy volunteers. Dynamic visual acuity (using a FVA measurement system) and higher-order aberrations (using a wavefront sensor) were compared in subjects wearing two types of soft contact lenses: 1-day Acuvue(®) (Vistakon, Jacksonville, FL) clear and the 1-day Acuvue(®) Define(TM) (Vistakon, Jacksonville, FL) tinted lens. The blink rates were recorded during FVA testing. The correlation between the difference of HOAs and differences in FVA values was analyzed. The mean LogMAR FVA scores with clear and tinted SCLs were 0.07 ± 0.13 and 0.14 ± 0.17 (P<0.05). The mean blink frequencies with clear and tinted SCL wear were 18.4 ± 8.3 and 25.3 ± 4.7 blinks/min (P<0.05). Both 3rd-order aberrations and total HOAs showed statistically significant differences between the two types of soft contact lenses for 6mm pupil measurements (P<0.05). A significant positive linear correlation was observed between ΔHOAs and ΔLogMAR FVA for 6mm pupil measurements (R=0.53, P=0.04). Tinted contact lens wear appears to induce a reduction in optical quality. Functional visual acuity measurement is a useful procedure to study the changes of visual performance and quality in tinted contact lens wear. Copyright © 2013 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.

  7. Potential sources of bacteria that are isolated from contact lenses during wear.

    Science.gov (United States)

    Willcox, M D; Power, K N; Stapleton, F; Leitch, C; Harmis, N; Sweeney, D F

    1997-12-01

    The aim of this paper was to determine the possible contamination sources of contact lenses during wear. Potential sources of the microbiota that colonized hydrogel contact lenses during wear were examined. The microorganisms that colonize contact lenses were grown, identified, and compared to those microorganisms that colonized the lower lid margins, upper bulbar conjunctiva, hands, and contact lens cases of contact lens wearers. In addition, the incidence of contamination of the domestic water supply in the Sydney area was obtained, and this was compared to the incidence of colonization of contact lenses by microorganisms in general and gram-negative bacteria in particular. There was a wide diversity of bacteria that were isolated from each site sampled. Coagulase-negative staphylococci and Propionibacterium spp. were the most common isolates from all ocular sites examined, and constituted the normal ocular microbiota. Other bacteria, including members of the families Enterobacteriaceae and Pseudomonadaceae, were isolated infrequently from all sites, but most frequently from contact lens cases. Statistical analysis revealed that there was a correlation between the isolation of bacteria from the contact lens and the lower lid margin (p microbiota. A correlation was also noted between the colonization of contact lenses by gram-negative bacteria and contamination of the domestic water supply. This study has demonstrated that the likely route for the normal ocular microbiota colonizing contact lenses is via the lid margins, whereas colonization by gram-negative bacteria, including potential agents of microbial keratitis, is likely to be from the domestic water supply.

  8. Bioinspired, biomimetic, double-enzymatic mineralization of hydrogels for bone regeneration with calcium carbonate

    DEFF Research Database (Denmark)

    Lopez-Heredia, Marco A.; Łapa, Agata; Mendes, Ana Carina Loureiro

    2017-01-01

    Hydrogels are popular materials for tissue regeneration. Incorporation of biologically active substances, e.g. enzymes, is straightforward. Hydrogel mineralization is desirable for bone regeneration. Here, hydrogels of Gellan Gum (GG), a biocompatible polysaccharide, were mineralized biomimetical...

  9. Microstructure-Wear Resistance Correlation and Wear Mechanisms of Spark Plasma Sintered Cu-Pb Nanocomposites

    Science.gov (United States)

    Sharma, Amit Siddharth; Biswas, Krishanu; Basu, Bikramjit

    2014-01-01

    The dispersion of a softer phase in a metallic matrix reduces the coefficient of friction (COF), often at the expense of an increased wear rate at the tribological contact. To address this issue, unlubricated fretting wear tests were performed on spark plasma sintered Cu-Pb nanocomposites against bearing steel. The sintering temperature and the Pb content as well as the fretting parameters were judiciously selected and varied to investigate the role of microstructure (grain size, second-phase content) on the wear resistance properties of Cu-Pb nanocomposites. A combination of the lowest wear rate (~1.5 × 10-6 mm3/Nm) and a modest COF (~0.4) was achieved for Cu-15 wt pct Pb nanocomposites. The lower wear rate of Cu-Pb nanocomposites with respect to unreinforced Cu is attributed to high hardness (~2 to 3.5 GPa) of the matrix, Cu2O/Fe2O3-rich oxide layer formation at tribological interface, and exuding of softer Pb particles. The wear properties are discussed in reference to the characteristics of transfer layer on worn surface as well as subsurface damage probed using focused ion beam microscopy. Interestingly, the flash temperature has been found to have insignificant effect on the observed oxidative wear, and alternative mechanisms are proposed. Importantly, the wear resistance properties of the nanocomposites reveal a weak Hall-Petch-like relationship with grain size of nanocrystalline Cu.

  10. Novel scalable silicone elastomer and poly(2-hydroxyethyl methacrylate) (PHEMA) composite materials for tissue engineering and drug delivery applications

    DEFF Research Database (Denmark)

    Mohanty, Soumyaranjan; Hemmingsen, Mette; Wojcik, Magdalena

    2013-01-01

    In recent years hydrogels have received increasing attention as potential materials for applications in regenerative medicine. They can be used for scaffold materials providing structural integrity to tissue constructs, for controlled delivery of drugs and proteins to cell and tissues......, and for support materials in tissue growth. However, the real challenge is to obtain sufficiently good mechanical properties of the hydrogel. The present study shows the combination of two normally non-compatible materials, silicone elastomer and poly(2-hydroxyethyl methacrylate) (PHEMA), into a novel composite...... material with increased hydrophilicity in regard to virgin silicone elastomer, making it suitable as a scaffold for tissue engineering and with the concomitant possibility for delivering drug from the scaffold to the tissue. Interpenetrating polymer networks (IPNs) of silicone elastomer and PHEMA...

  11. Preparation of bacterial cellulose based hydrogels and their viscoelastic behavior

    Science.gov (United States)

    Shah, Rushita; Vyroubal, Radek; Fei, Haojei; Saha, Nabanita; Kitano, Takeshi; Saha, Petr

    2015-04-01

    Bacterial cellulose (BC) based hydrogels have been prepared in blended with carboxymethylcellulose and polyvinyl pyrrolidone by using heat treatment. The properties of BC-CMC and BC-PVP hydrogels were compared with pure BC, CMC and PVP hydrogels. These hydrogels were investigated by measuring their structural, morphological and viscoelastic properties. Through the morphological images, alignment of the porous flake like structures could be seen clearly within the inter-polymeric network of the hydrogels. Also, the detail structure analysis of the polymers blended during the hydrogel formation confirms their interactions with each other were studied. Further, the viscoelastic behavior of all the hydrogels in terms of elastic and viscous property was studied. It is observed that at 1% strain, including CMC and PVP hydrogels, all the BC based hydrogels exhibited the linear trend throughout. Also the elastic nature of the material remains high compared to viscous nature. Moreover, the changes could be noticed in case of blended polymer based hydrogels. The values of complex viscosity (η*) decreases with increase in angular frequency within the range of ω = 0.1-100 rad.s-1.

  12. REDUCED ENGINE FRICTION AND WEAR

    Energy Technology Data Exchange (ETDEWEB)

    Ron Matthews

    2005-05-01

    This Final Technical Report discusses the progress was made on the experimental and numerical tasks over the duration of this project regarding a new technique for decreasing engine friction and wear via liner rotation. The experimental subtasks involved quantifying the reduction in engine friction for a prototype rotating liner engine relative to a comparable baseline engine. Both engine were single cylinder conversions of nominally identical production four-cylinder engines. Hot motoring tests were conducted initially and revealed that liner rotation decreased engine friction by 20% under motoring conditions. A well-established model was used to estimate that liner rotation should decrease the friction of a four-cylinder engine by 40% under hot motoring conditions. Hot motoring tear-down tests revealed that the crankshaft and valve train frictional losses were essentially the same for the two engines, as expected. However, the rotating liner engine had much lower (>70%) piston assembly friction compared to the conventional engine. Finally, we used the Instantaneous IMEP method to compare the crank-angle resolved piston assembly friction for the two engines. Under hot motoring conditions, these measurements revealed a significant reduction in piston assembly friction, especially in the vicinity of compression TDC when the lubrication regime transitions from hydrodynamic through mixed and into boundary friction. We have some remaining problems with these measurements that we expect to solve during the next few weeks. We will then perform these measurements under firing conditions. We also proposed to improve the state-of-the-art of numerical modeling of piston assembly friction for conventional engines and then to extend this model to rotating liner engines. Our research team first modeled a single ring in the Purdue ring-liner test rig. Our model showed good agreement with the test rig data for a range of speeds and loads. We then modeled a complete piston

  13. Structural transformations in wear resistance of iron- and cobalt-based amorphous alloys during abrasive wear

    Science.gov (United States)

    Korshunov, L. G.; Shabashov, V. A.; Chernenko, N. L.

    2010-04-01

    The wear resistance and structural changes in a number of amorphous alloys based on iron and cobalt and in high-carbon tool steels are studied during wear by a fixed abrasive (crondum, Carborundum) at room temperature and -196°C. The abrasive wear resistance of the amorphous alloys is shown to be 1.6-3.1 lower than that of the high-carbon tool steels having a similar hardness. The relatively low level of the abrasive wear resistance of the amorphous alloys is assumed to be caused by strain softening of their surface during wear. A nanocrystalline structure is found to form in local microvolumes in a thin deformed surface layer of the alloys.

  14. Polymer Micelles Laden Hydrogel Contact Lenses for Ophthalmic Drug Delivery.

    Science.gov (United States)

    Hu, Xiaohong; Tan, Huaping; Chen, Pin; Wang, Xin; Pang, Juan

    2016-06-01

    Hydrogel contact lens is an attractive drug carrier for the delivery of ophthalmic drugs. But limited drug loading capacity and burst release restricted its application in this field. Polymer micelle laden hydrogel contact lenses were designed for ophthalmic drug delivery in the work. β-CD/PAA/PEG ternary system was chosen to form polymer micelle. The micelle size could be adjusted by β-CD content and PAA/PEG concentration. The zeta potential of micelle was irrelevant to β-CD content, but influenced by PAA/PEG concentration. The absorbed drug concentration in micelle solution depended on both β-CD content and PAA/PEG concentration. Polymer micelle laden hydrogels were obtained by radical polymerization in situ. The transparency of polymer micelle laden hydrogel declined with PAA/PEG concentration increasing. The equilibrium water content and water loss showed that polymer micelle laden hydrogel with higher PAA/PEG concentration was in a higher swollen state. The dynamic viscoelastic properties howed that all polymer micelle laden hydrogels had some characteristics of crosslinked elastomers. The surface structure of freeze dried composite hydrogels was different from freeze dried pure hydrogel. The drug loading and releasing behaviors were detected to evaluate the drug loading and releasing capacity of hydrogels using orfloxacin and puerarin as model drugs. The results indicated the polymer micelle in hydrogel could hold or help to hold some ophthalmic drugs, and slow down orfloxacin release speed or keep puerarin stably stay for a time in hydrogels. In the end, it was found that the transparency of composite hydrogel became better after the hydrogel had been immersed in PBS for several weeks.

  15. Enhancement of Curcumin Bioavailability Using Nanocellulose Reinforced Chitosan Hydrogel

    Directory of Open Access Journals (Sweden)

    Thennakoon M. Sampath Udeni Gunathilake

    2017-02-01

    Full Text Available A unique biodegradable, superporous, swellable and pH sensitive nanocellulose reinforced chitosan hydrogel with dynamic mechanical properties was prepared for oral administration of curcumin. Curcumin, a less water-soluble drug was used due to the fact that the fast swellable, superporous hydrogel could release a water-insoluble drug to a great extent. CO2 gas foaming was used to fabricate hydrogel as it eradicates using organic solvents. Field emission scanning electron microscope images revealed that the pore size significantly increased with the formation of widely interconnected porous structure in gas foamed hydrogels. The maximum compression of pure chitosan hydrogel was 25.9 ± 1 kPa and it increased to 38.4 ± 1 kPa with the introduction of 0.5% cellulose nanocrystals. In vitro degradation of hydrogels was found dependent on the swelling ratio and the amount of CNC of the hydrogel. All the hydrogels showed maximum swelling ratios greater than 300%. The 0.5% CNC-chitosan hydrogel showed the highest swelling ratio of 438% ± 11%. FTIR spectrum indicated that there is no interaction between drug and ingredients present in hydrogels. The drug release occurred in non-Fickian (anomalous manner in simulated gastric medium. The drug release profiles of hydrogels are consistent with the data obtained from the swelling studies. After gas foaming of the hydrogel, the drug loading efficiency increased from 41% ± 2.4% to 50% ± 2.0% and release increased from 0.74 to 1.06 mg/L. The drug release data showed good fitting to Ritger-Peppas model. Moreover, the results revealed that the drug maintained its chemical activity after in vitro release. According to the results of this study, CNC reinforced chitosan hydrogel can be suggested to improve the bioavailability of curcumin for the absorption from stomach and upper intestinal tract.

  16. Polyacrylamide Hydrogel Properties for Horticultural Applications

    Science.gov (United States)

    Polyacrylamide (PAAm) hydrogels are commonly employed to ensure hydration of the growth media and minimize crop losses during the crop production and postproduction phases in horticulture. However, studies of the effect of these materials have shown that they have a minimal effect on crop life and q...

  17. Polymer hydrogels as optimized delivery systems

    Energy Technology Data Exchange (ETDEWEB)

    Batista, Jorge G.S.; Varca, Gustavo H.C.; Ferraz, Caroline C.; Garrido, Gabriela P.; Diniz, Bruna M.; Carvalho, Vinicius S.; Lugao, Ademar B., E-mail: jorgegabriel@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Hydrogels are formed by polymers capable of absorbing large quantities of water. They consist of one or more three-dimensionally structured polymer networks formed by macromolecular chains linked by covalent bonds-crosslinks - and physical interactions. The application of hydrogels, has been widely studied. Biodegradable synthetic or natural polymers such as chitosan, starch and poly-lactic-co-glycolic acid, have properties that allow the development of biodegradable systems for drug and nutraceutics delivery. This study aimed to develop polymeric hydrogels based on polyvinyl alcohol, polyacrylamide and polyvinylpyrrolidone using ionizing radiation in order to develop hydrogels for improved loading and release of compounds. Polymer solutions were solubilized in water and poured into thermoformed packages. After sealing, the material was subjected to γ-irradiation at 25kGy. The samples were assayed by means of mechanical properties, gel fraction and swelling degree. Nanostructure characterization was performed using Flory's equation to determine crosslinking density. The systems developed showed swelling degree and adequate mechanical resistance. The nanostructure evaluation showed different results for each system demonstrating the need of choosing the polymer based on the specific properties of each material. (author)

  18. Incisor wear and age in Yellowstone bison

    Science.gov (United States)

    Christianson, D.A.; Gogan, P.J.P.; Podruzny, K.M.; Olexa, E.M.

    2005-01-01

    Biologists commonly use tooth eruption and wear patterns or cementum annuli techniques to estimate age of ungulates. However, in some situations the accuracy or sampling procedures of either approach are undesirable. We investigated the progression of several quantitative measures of wear with age, using permanent first incisors from Yellowstone bison (Bison bison), and tested for differences between sexes and herds. We further investigated the relationship of wear and age to explore an age-estimation method. Labial-lingual width (LLW) correlated best with assigned age (r2=0.66, males; r2=0.76 females). Labial-lingual width differed between sexes, with females showing ∼0.2 mm more wear than males. Additionally, differences in rate of wear existed between bison of the northern and central Yellowstone herds (1.2 and 0.9 mm/year, respectively). We developed a regression formula to test the power of LLW as an estimator of Yellowstone bison age. Our method provided estimated ages within 1 year of the assigned age 73% and 82% of the time for female and male bison, respectively.

  19. Dental Wear: A Scanning Electron Microscope Study

    Directory of Open Access Journals (Sweden)

    Luca Levrini

    2014-01-01

    Full Text Available Dental wear can be differentiated into different types on the basis of morphological and etiological factors. The present research was carried out on twelve extracted human teeth with dental wear (three teeth showing each type of wear: erosion, attrition, abrasion, and abfraction studied by scanning electron microscopy (SEM. The study aimed, through analysis of the macro- and micromorphological features of the lesions (considering the enamel, dentin, enamel prisms, dentinal tubules, and pulp, to clarify the different clinical and diagnostic presentations of dental wear and their possible significance. Our results, which confirm current knowledge, provide a complete overview of the distinctive morphology of each lesion type. It is important to identify the type of dental wear lesion in order to recognize the contributing etiological factors and, consequently, identify other more complex, nondental disorders (such as gastroesophageal reflux, eating disorders. It is clear that each type of lesion has a specific morphology and mechanism, and further clinical studies are needed to clarify the etiological processes, particularly those underlying the onset of abfraction.

  20. Brush seal shaft wear resistant coatings

    Science.gov (United States)

    Howe, Harold

    1995-03-01

    Brush seals suffer from high wear, which reduces their effectiveness. This work sought to reduce brush seal wear by identifying and testing several industry standard coatings. One of the coatings was developed for this work. It was a co-sprayed PSZ with boron-nitride added for a high temperature dry lubricant. Other coatings tested were a PSZ, chrome carbide and a bare rotor. Testing of these coatings included thermal shocking, tensile testing and wear/coefficient of friction testing. Wear testing consisted of applying a coating to a rotor and then running a sample tuft of SiC ceramic fiber against the coating. Surface speeds at point of contact were slightly over 1000 ft/sec. Rotor wear was noted, as well as coefficient of friction data. Results from the testing indicates that the oxide ceramic coatings cannot withstand the given set of conditions. Carbide coatings will not work because of the need for a metallic binder, which oxidizes in the high heat produced by friction. All work indicated a need for a coating that has a lubricant contained within itself and the coating must be resistant to an oxidizing environment.

  1. Impact wear behaviors of Hadfield manganese steel

    Institute of Scientific and Technical Information of China (English)

    FANG Liang; XU Yun-hua; CEN Qi-hong; ZHU Jin-hua

    2005-01-01

    Impact wear behaviors of Hadfield manganese steel at different impact angles were investigated. The results of impact wear tests show that there exists a critical impact load for Hadfield steel. The wear rate suddenly turns down after some impact cycles when the impact load is greater than the critical load. The critical impact load is smaller than 8.2 J in this research because the nano-sized austenitic grains embedded in amorphous delay the crack propagation in subsurface. From high resolution transmission electron microscope (HRTEM) examination of subsurface microstructure, it is found that a large amount of nano-sized grains embedded in bulk amorphous matrix are fully developed and no martensitic transformation occurs during the impact wear process. The analytical results of worn surface morphology and debris indicate that the initiation of crack, propagation and spalling are restricted in the amorphous phase, resulting in the size distribution of debris in nano-sizes, which is the reason why the wear rate of Hadfield steel is greatly decreased at high impact load.

  2. Role of synergy between wear and corrosion in degradation of materials

    Science.gov (United States)

    Azzi, Marwan

    Tribocorrosion is a term used to describe the material degradation due to the combination of electrochemical and tribological processes. Due to a synergetic effect, the material loss can be larger than the sum of the losses due to wear and corrosion acting separately. In this thesis, the synergy of wear and corrosion was investigated for different types of material, namely the Ti-6Al-4V alloy, the SS316L stainless steel coated with a thin film of Diamond Like Carbon (DLC), and the SS301 stainless steel coated with a thin film of chromium silicon nitride (CrSiN). A tribocorrosion apparatus was designed and constructed to conduct wear experiments in corrosive media. Sliding ball-on-plate configuration was used in this design, where the contact between the ball and the specimen is totally immersed in the test electrolyte. The specimen was connected to a potentiostat to control its electrochemical parameters, namely the potential and the current. Electrochemical techniques were used to control the kinetics of corrosion reactions, and therefore it was possible to assess separately the role of corrosion and wear in the total degradation of material, and to evaluate the synergy between them. For Ti-6Al-4V, it was found that the corrosion and tribocorrosion depend strongly on the structure of the material. The alpha-equiaxed microstructure with fine dispersed beta-phase exhibited the best corrosion resistance. The corrosion resistance was found to decrease when the basal plane was preferentially aligned parallel to the surface, which is attributed to a low resistance to charge transfer in the oxide films formed on this plane. On the other hand, when wear and corrosion were involved simultaneously, the oxide layer protecting the substrate against dissolution was mechanically destroyed leading to a high corrosion rate. It was found that the hardness was the most important factor determining the tribocorrosion behavior of the Ti-6Al-4V alloy; samples with high hardness

  3. Application of Silicon Nitride (Si3N4) Ceramics in Ball Bearing

    OpenAIRE

    2016-01-01

    This paper is discus about silicon nitride ceramics in application to ball bearing. Silicon nitride (Si3N4) have advance properties such as consistent at temperature operation up to 1000°C, greater thermal shock resistance, lower density and low thermal expansion. This properties gives some benefit for ball bearing material such as higher running speed, reduce vibration of the shaft, will improve the life time and maintenance cost, lower heat generated, less energy consumption, lower wear ...

  4. [Wear and different restorative materials--a review].

    Science.gov (United States)

    Beyth, N; Sharon, E; Lipovetsky, M; Smidt, A

    2006-07-01

    Wear of materials is a complex and unpredictable phenomenon. The variables affecting the mechanism of wear include the properties of the two contacting materials and the surrounding and interfacial media. This paper reviews the dental wear of different restorative materials and their counter effect on the tooth structure. It presents the updated classifications for tooth surface lesions termed dental wear, and discusses the wear behavior of various restorative materials. Some guidelines for restorative material selection are given. Clinical wear bears a multifactorial etiology, understanding the mechanism of action is an important step in an appropriate restoration material selection. Each material selected should meet the individual wear behavior and needs. Individual factors may enhance the wear rates: aggressive tooth brushing, parafunctions, diet, acidic/aqueous environment, surface geometry, and diminished tooth support. Supportive treatment following restoration is important to monitor wear rates.

  5. Friction and Wear Performance of Boron Doped, Undoped Microcrystalline and Fine Grained Composite Diamond Films

    Institute of Scientific and Technical Information of China (English)

    WANG Xinchang; WANG Liang; SHEN Bin; SUN Fanghong

    2015-01-01

    Chemical vapor deposition (CVD) diamond films have attracted more attentions due to their excellent mechanical properties. Whereas as-fabricated traditional diamond films in the previous studies don’t have enough adhesion or surface smoothness, which seriously impact their friction and wear performance, and thus limit their applications under extremely harsh conditions. A boron doped, undoped microcrystalline and fine grained composite diamond (BD-UM-FGCD) film is fabricated by a three-step method adopting hot filament CVD (HFCVD) method in the present study, presenting outstanding comprehensive performance, including the good adhesion between the substrate and the underlying boron doped diamond (BDD) layer, the extremely high hardness of the middle undoped microcrystalline diamond (UMCD) layer, as well as the low surface roughness and favorable polished convenience of the surface fine grained diamond (FGD) layer. The friction and wear behavior of this composite film sliding against low-carbon steel and silicon nitride balls are studied on a ball-on-plate rotational friction tester. Besides, its wear rate is further evaluated under a severer condition using an inner-hole polishing apparatus, with low-carbon steel wire as the counterpart. The test results show that the BD-UM-FGCD film performs very small friction coefficient and great friction behavior owing to its high surface smoothness, and meanwhile it also has excellent wear resistance because of the relatively high hardness of the surface FGD film and the extremely high hardness of the middle UMCD film. Moreover, under the industrial conditions for producing low-carbon steel wires, this composite film can sufficiently prolong the working lifetime of the drawing dies and improve their application effects. This research develops a novel composite diamond films owning great comprehensive properties, which have great potentials as protecting coatings on working surfaces of the wear-resistant and anti

  6. Friction and wear performance of boron doped, undoped microcrystalline and fine grained composite diamond films

    Science.gov (United States)

    Wang, Xinchang; Wang, Liang; Shen, Bin; Sun, Fanghong

    2015-01-01

    Chemical vapor deposition (CVD) diamond films have attracted more attentions due to their excellent mechanical properties. Whereas as-fabricated traditional diamond films in the previous studies don't have enough adhesion or surface smoothness, which seriously impact their friction and wear performance, and thus limit their applications under extremely harsh conditions. A boron doped, undoped microcrystalline and fine grained composite diamond (BD-UM-FGCD) film is fabricated by a three-step method adopting hot filament CVD (HFCVD) method in the present study, presenting outstanding comprehensive performance, including the good adhesion between the substrate and the underlying boron doped diamond (BDD) layer, the extremely high hardness of the middle undoped microcrystalline diamond (UMCD) layer, as well as the low surface roughness and favorable polished convenience of the surface fine grained diamond (FGD) layer. The friction and wear behavior of this composite film sliding against low-carbon steel and silicon nitride balls are studied on a ball-on-plate rotational friction tester. Besides, its wear rate is further evaluated under a severer condition using an inner-hole polishing apparatus, with low-carbon steel wire as the counterpart. The test results show that the BD-UM-FGCD film performs very small friction coefficient and great friction behavior owing to its high surface smoothness, and meanwhile it also has excellent wear resistance because of the relatively high hardness of the surface FGD film and the extremely high hardness of the middle UMCD film. Moreover, under the industrial conditions for producing low-carbon steel wires, this composite film can sufficiently prolong the working lifetime of the drawing dies and improve their application effects. This research develops a novel composite diamond films owning great comprehensive properties, which have great potentials as protecting coatings on working surfaces of the wear-resistant and anti

  7. Transparent hydrogel with enhanced water retention capacity by introducing highly hydratable salt

    Energy Technology Data Exchange (ETDEWEB)

    Bai, Yuanyuan; Xiang, Feng; Wang, Hong, E-mail: hwang@mail.xjtu.edu.cn, E-mail: suo@seas.harvard.edu [Electronic Materials Research Laboratory, School of Electronics and Information Engineering, Xi' an Jiaotong University, Xi' an 710049 (China); Chen, Baohong; Zhou, Jinxiong [State Key Laboratory for Strength and Vibration of Mechanical Structures, International Center for Applied Mechanics and School of Aerospace, Xi' an Jiaotong University, Xi' an 710049 (China); Suo, Zhigang, E-mail: hwang@mail.xjtu.edu.cn, E-mail: suo@seas.harvard.edu [School of Engineering and Applied Sciences, Kavli Institute of Bionano Science and Technology, Harvard University, Cambridge, Massachusetts 02138 (United States)

    2014-10-13

    Polyacrylamide hydrogels containing salt as electrolyte have been used as highly stretchable transparent electrodes in flexible electronics, but those hydrogels are easy to dry out due to water evaporation. Targeted, we try to enhance water retention capacity of polyacrylamide hydrogel by introducing highly hydratable salts into the hydrogel. These hydrogels show enhanced water retention capacity in different level. Specially, polyacrylamide hydrogel containing high content of lithium chloride can retain over 70% of its initial water even in environment with relative humidity of only 10% RH. The excellent water retention capacities of these hydrogels will make more applications of hydrogels become possible.

  8. Wear Resistant Amorphous and Nanocomposite Coatings

    Energy Technology Data Exchange (ETDEWEB)

    Racek, O

    2008-03-26

    Glass forming materials (critical cooling rate <10{sup 4}K.s{sup -1}) are promising for their high corrosion and wear resistance. During rapid cooling, the materials form an amorphous structure that transforms to nanocrystalline during a process of devitrification. High hardness (HV 1690) can be achieved through a controlled crystallization. Thermal spray process has been used to apply coatings, which preserves the amorphous/nanocomposite structure due to a high cooling rate of the feedstock particles during the impact on a substrate. Wear properties have been studied with respect to process conditions and feedstock material properties. Application specific properties such as sliding wear resistance have been correlated with laboratory tests based on instrumented indentation and scratch tests.

  9. A View on Wear Mechanism of Metallic Card Clothing

    Institute of Scientific and Technical Information of China (English)

    WU Liang; WANG Wen-qiang; NI Huai-sheng

    2008-01-01

    The wear mechanism of metallic card clothing,used in textile industry, was analyzed. A fast wear test for metallic card clothing racks was developed, which was used as collecting the wear metal particles. The failure type of card clothing was analyzed by the mean of scanning electron microscopy (SEM) and ferro-spectrum technology. The results show that the main wear mechanism of metallic card clothing is low load and high repetition interval fatigue wear caused by friction force between fiber and metal wire teeth.The appropriate quenching microstmcture, which improves the wear resistance of the metallic card clothing rack is also discussed.

  10. High Strength and Wear Resistant Aluminum Alloy for High Temperature Applications

    Science.gov (United States)

    Lee, Jonathan A.; Chen, Po Shou

    2003-01-01

    Originally developed by NASA as high performance piston alloys to meet U.S. automotive legislation requiring low exhaust emission, the novel NASA alloys now offer dramatic increase in tensile strength for many other applications at elevated temperatures from 450 F (232 C) to about 750 F (400 C). It is an ideal low cost material for cast automotive components such as pistons, cylinder heads, cylinder liners, connecting rods, turbo chargers, impellers, actuators, brake calipers and rotors. It can be very economically produced from conventional permanent mold, sand casting or investment casting, with silicon content ranging from 6% to 18%. At high silicon levels, the alloy exhibits excellent thermal growth stability, surface hardness and wear resistant properties.

  11. Versatile Molding Process for Tough Cellulose Hydrogel Materials.

    Science.gov (United States)

    Kimura, Mutsumi; Shinohara, Yoshie; Takizawa, Junko; Ren, Sixiao; Sagisaka, Kento; Lin, Yudeng; Hattori, Yoshiyuki; Hinestroza, Juan P

    2015-11-05

    Shape-persistent and tough cellulose hydrogels were fabricated by a stepwise solvent exchange from a homogeneous ionic liquid solution of cellulose exposure to methanol vapor. The cellulose hydrogels maintain their shapes under changing temperature, pH, and solvents. The micrometer-scale patterns on the mold were precisely transferred onto the surface of cellulose hydrogels. We also succeeded in the spinning of cellulose hydrogel fibers through a dry jet-wet spinning process. The mechanical property of regenerated cellulose fibers improved by the drawing of cellulose hydrogel fibers during the spinning process. This approach for the fabrication of tough cellulose hydrogels is a major advance in the fabrication of cellulose-based structures with defined shapes.

  12. Antimicrobial Activity of Chitosan-Carbon Nanotube Hydrogels

    Directory of Open Access Journals (Sweden)

    Jayachandran Venkatesan

    2014-05-01

    Full Text Available In the present study, we have prepared chitosan-carbon nanotube (Chitosan-CNT hydrogels by the freeze-lyophilization method and examined their antimicrobial activity. Different concentrations of CNT were used in the preparation of Chitosan-CNT hydrogels. These differently concentrated CNT hydrogels were chemically characterized using Fourier Transform-Infrared Spectroscopy, Scanning Electron Microscopy and Optical microscopy. The porosity of the hydrogels were found to be >94%. Dispersion of chitosan was observed in the CNT matrix by normal photography and optical microscopy. The addition of CNT in the composite scaffold significantly reduced the water uptake ability. In order to evaluate antimicrobial activity, the serial dilution method was used towards Staphylococcus aureus, Escherichia coli and Candida tropicalis. The composite Chitosan-CNT hydrogel showed greater antimicrobial activity with increasing CNT concentration, suggesting that Chitosan-CNT hydrogel scaffold will be a promising biomaterial in biomedical applications.

  13. Comparison of Pectin Hydrogel Collection Methods in Microfluidic Device

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chaeyeon; Park, Ki-Su; Kang, Sung-Min; Kim, Jongmin; Song, YoungShin; Lee, Chang-Soo [Chungnam National University, Daejeon (Korea, Republic of)

    2015-12-15

    This study investigated the effect of different collection methods on physical properties of pectin hydrogels in microfluidic synthetic approach. The pectin hydrogels were simply produced by the incorporation of calcium ions dissolved in continuous mineral oil. Then, different collection methods, pipetting, tubing, and settling, for harvesting pectin hydrogels were applied. The settling method showed most uniform and monodispersed hydrogels. In the case of settling, a coefficient of variation was 3.46 which was lower than pipetting method (18.60) and tubing method (14.76). Under the settling method, we could control the size of hydrogels, ranging from 30 μm to 180 μm, by simple manipulation of the viscosity of pectin and volumetric flow rate of dispersed and continuous phase. Finally, according to the characteristics of simple encapsulation of biological materials, we envision that the pectin hydrogels can be applied to drug delivery, food, and biocompatible materials.

  14. ADDITIVE-INDUCED ENHANCEMENT OF OPTICAL CLARITY OF POLYACRYLAMIDE HYDROGEL

    Institute of Scientific and Technical Information of China (English)

    Jeffery Franklin; Zhi Yuan Wang

    2003-01-01

    The aqueous polymerization of acrylamide and crosslinking with N,N-methylenebisacrylamide afforded hydrogels displaying high levels of light scattering (poor optical clarity). Enhancement of the optical clarity within a polyacrylamide (PAm) hydrogel was accomplished through the implementation of"refractive index matching", Water-soluble additives were utilised to better match the refractive index inhomogeneities throughout a given hydrogel. This resulted in lower light scattering within the system and hence improved clarity. Amino acids, sugars, polymers, and other water-soluble additives such as glycerol were investigated by this methodology. Most additives investigated displayed potential for effectively reducing the light scattering within a PAm hydrogel as a function of increased additive concentration. On increasing the refractive index of the water medium, the overall refractive index of a PAm hydrogel was also observed to increase. This provided a quantitative means of determining the effectiveness of a given additive for improving the optical clarity within a hydrogel.

  15. Swelling Behaviors of Polyaniline-Poly(Acrylic Acid) Hydrogels

    Institute of Scientific and Technical Information of China (English)

    ZHANG You-wei; ZHAO Jiong-xin; LI Xiao-feng; TAO Yong; WU Cheng-xun

    2005-01-01

    Using poly(acrylic acid) (PAA) aqueous solution, NaOH aqueous solution, aniline(An) and ammonim persulfate(APS), PAn-PAA hydrogels with a semi-interpenetrating structure connected by physical interlocks, chemical ion bonds and hydrogen bonds wcre prepared. The swelling properties of the hydrogels in solutions of different pH values(adjusted by adding NaOH or HCl) were studied. All the hydrogels prepared have similar swelling curves (the curves of equilibrium swelling ratio vs. pH value) and reach their maximum swelling at pH of 8 - 10. The maximum swelling ratio of the hydrogels is dependent on composition, including molecular weight of PAA, polymer content of the hydrogel,and molar ratios of AA to An, APS to An, and NaOH to AA.And the compositional dependence of the swelling capacity of PAn-PAA hydrogels was also studied.

  16. Stimuli-responsive hydrogels in drug delivery and tissue engineering.

    Science.gov (United States)

    Sood, Nikhil; Bhardwaj, Ankur; Mehta, Shuchi; Mehta, Abhinav

    2016-01-01

    Hydrogels are the three-dimensional network structures obtained from a class of synthetic or natural polymers which can absorb and retain a significant amount of water. Hydrogels are one of the most studied classes of polymer-based controlled drug release. These have attracted considerable attention in biochemical and biomedical fields because of their characteristics, such as swelling in aqueous medium, biocompatibility, pH and temperature sensitivity or sensitivity towards other stimuli, which can be utilized for their controlled zero-order release. The hydrogels are expected to explore new generation of self-regulated delivery system having a wide array of desirable properties. This review highlights the exciting opportunities and challenges in the area of hydrogels. Here, we review different literatures on stimuli-sensitive hydrogels, such as role of temperature, electric potential, pH and ionic strength to control the release of drug from hydrogels.

  17. Dielectric properties of Rhodamine-B and metal doped hydrogels

    Energy Technology Data Exchange (ETDEWEB)

    Okutan, M. [Department of Physics, Yıldız Technical University, 34210 Istanbul (Turkey); Coşkun, R. [Department of Chemistry, Bozok University, 66100 Yozgat (Turkey); Öztürk, M. [Institute of Science, Niğde University, 51240 Niğde (Turkey); Yalçın, O., E-mail: o.yalcin@nigde.edu.tr [Department of Physics, Niğde University, 51240 Niğde (Turkey)

    2015-01-15

    The electric and dielectric properties of Rhodamine-B (RB) and metal ions (Ag{sup +}, Co{sup 2+}, Cr{sup 3+}, Mn{sup 2+} and Ni{sup 2+}) doped hydrogels have been analyzed in an extended frequency range by impedance spectroscopy. The RB doped hydrogels has been found to be sensitive to ionic conduction and electrode polarization according to the metal doped hydrogels. We have shown that the ionic conductive of RB doped hydrogels is originated from the free ions motion within the doped hydrogels at high frequency. We have also taken into account the Cl{sup −} and N{sup +} ions in the structure of RB provide additional ionic contribution to RB doped hydrogels.

  18. Mechanical Behavior of Tough Hydrogels for Structural Applications

    Science.gov (United States)

    Illeperuma, Widusha Ruwangi Kaushalya

    Hydrogels are widely used in many commercial products including Jell-O, contact lenses, and superabsorbent diapers. In recent decades, hydrogels have been under intense development for biomedical applications, such as scaffolds in tissue engineering, carriers for drug delivery, and valves in microfluidic systems. But the scope is severely limited as conventional hydrogels are weak and brittle and are not very stretchable. This thesis investigates the approaches that enhance the mechanical properties of hydrogels and their structural applications. We discov¬ered a class of exceptionally stretchable and tough hydrogels made from poly-mers that form networks via ionic and covalent crosslinks. Although such a hydrogel contains ~90% water, it can be stretched beyond 20 times its initial length, and has a fracture energy of ~9000 J/m2. The combination of large stretchability, remarkable toughness, and recoverability of stiffness and toughness, along with easy synthesis makes this material much superior over existing hydrogels. Extreme stretchability and blunted crack tips of these hydrogels question the validity of traditional fracture testing methods. We re-examine a widely used pure shear test method to measure the fracture energy. With the experimental and simulation results, we conclude that the pure shear test method can be used to measure fracture energy of extremely stretchable materials. Even though polyacrylamide-alginate hydrogels have an extremely high toughness, it has a relatively low stiffness and strength. We improved the stiffness and strength by embedding fibers. Most hydrogels are brittle, allowing the fibers to cut through the hydrogel when the composite is loaded. But tough hydrogel composites do not fail by the fibers cutting the hydrogel; instead, it undergoes large deforming by fibers sliding through the matrix. Hydrogels were not considered as materials for structural applications. But with enhanced mechanical properties, they have opened up

  19. The Delamination Theory of Wear - III

    Science.gov (United States)

    1977-12-01

    117. 18 A. P. Orson , J. Mach. Phys. Solids, 2 (1954) 197 - 211, 19 D. R. Wheeler and D, H. Buckley, Wear, 83 (1975) 65. 20 V. C, Scott end H. Wilman...papers were also published In Volume 44 no. I of the Journal Wear, edited by1). Scott . "ELSEVIER SEQUOIA S.A., LAUSANNE, 1977 APproved for public ioleoee...possible without the enthusiasm and support of Messrs. Douglas Scott and VOrnon C, Westoott. This kind of research cannot reodily be undertaken at a

  20. Consideration of wear rates at high velocity

    Science.gov (United States)

    Hale, Chad S.

    The development of the research presented here is one in which high velocity relative sliding motion between two bodies in contact has been considered. Overall, the wear environment is truly three-dimensional. The attempt to characterize three-dimensional wear was not economically feasible because it must be analyzed at the micro-mechanical level to get results. Thus, an engineering approximation was carried out. This approximation was based on a metallographic study identifying the need to include viscoplasticity constitutive material models, coefficient of friction, relationships between the normal load and velocity, and the need to understand wave propagation. A sled test run at the Holloman High Speed Test Track (HHSTT) was considered for the determination of high velocity wear rates. In order to adequately characterize high velocity wear, it was necessary to formulate a numerical model that contained all of the physical events present. The experimental results of a VascoMax 300 maraging steel slipper sliding on an AISI 1080 steel rail during a January 2008 sled test mission were analyzed. During this rocket sled test, the slipper traveled 5,816 meters in 8.14 seconds and reached a maximum velocity of 1,530 m/s. This type of environment was never considered previously in terms of wear evaluation. Each of the features of the metallography were obtained through micro-mechanical experimental techniques. The byproduct of this analysis is that it is now possible to formulate a model that contains viscoplasticity, asperity collisions, temperature and frictional features. Based on the observations of the metallographic analysis, these necessary features have been included in the numerical model, which makes use of a time-dynamic program which follows the movement of a slipper during its experimental test run. The resulting velocity and pressure functions of time have been implemented in the explicit finite element code, ABAQUS. Two-dimensional, plane strain models

  1. Wear Analysis of Wind Turbine Gearbox Bearings

    Energy Technology Data Exchange (ETDEWEB)

    Blau, Peter Julian [ORNL; Walker, Larry R [ORNL; Xu, Hanbing [ORNL; Parten, Randy J [ORNL; Qu, Jun [ORNL; Geer, Tom [ORNL

    2010-04-01

    The objective of this effort was to investigate and characterize the nature of surface damage and wear to wind turbine gearbox bearings returned from service in the field. Bearings were supplied for examination by S. Butterfield and J. Johnson of the National Wind Technology Center (NREL), Boulder, Colorado. Studies consisted of visual examination, optical and electron microscopy, dimensional measurements of wear-induced macro-scale and micro-scale features, measurements of macro- and micro-scale hardness, 3D imaging of surface damage, studies of elemental distributions on fracture surfaces, and examinations of polished cross-sections of surfaces under various etched and non-etched conditions.

  2. Gradient Index in Wear Debris Image Collection

    Institute of Scientific and Technical Information of China (English)

    LVZhi-yong; GAOHui-liang; YANXin-ping

    2004-01-01

    In order to solve a problem of oil on-line monitoring, this instrument adopts a prinripium of self-focus lens of Gradieat index fiber( GRIN Len) to design optics system and magnetic circuit. For the magnetic circuit, the monitor can catch particle wear debris in oil. And for the optics circuit. GRIN Len can transfer image of debris to apparatus of gather image, e . g, CCD and camera. And the image of debris is transferred to computer for analyzing seize and physiognomy of debris. The character of the monitor is of micro weight, micro volume andcurve imaging And it is directly pluged into oil to catch image of wear particles.

  3. Surface engineering for enhanced performance against wear

    CERN Document Server

    2013-01-01

    Surface Engineering constitutes a variety of processes and sub processes. Each chapter of this work covers specific processes by experts working in the area. Included for each topic are tribological performances for each process as well as results of recent research. The reader also will benefit from in-depth studies of diffusion coatings, nanocomposite films for wear resistance, surfaces for biotribological applications, thin-film wear, tribology of thermal sprayed coatings, hardfacing, plating for tribology and high energy beam surface modifications. Material scientists as well as engineers working with surface engineering for tribology will be particularly interested in this work.

  4. Photochemical Patterning of Ionically Cross-Linked Hydrogels

    Directory of Open Access Journals (Sweden)

    Marion Bruchet

    2013-08-01

    Full Text Available Iron(III cross-linked alginate hydrogel incorporating sodium lactate undergoes photoinduced degradation, thus serving as a biocompatible positive photoresist suitable for photochemical patterning. Alternatively, surface etching of iron(III cross-linked hydrogel contacting lactic acid solution can be used for controlling the thickness of the photochemical pattering. Due to biocompatibility, both of these approaches appear potentially useful for advanced manipulation with cell cultures including growing cells on the surface or entrapping them within the hydrogel.

  5. 4D Printing with Mechanically Robust, Thermally Actuating Hydrogels.

    Science.gov (United States)

    Bakarich, Shannon E; Gorkin, Robert; in het Panhuis, Marc; Spinks, Geoffrey M

    2015-06-01

    A smart valve is created by 4D printing of hydrogels that are both mechanically robust and thermally actuating. The printed hydrogels are made up of an interpenetrating network of alginate and poly(N-isopropylacrylamide). 4D structures are created by printing the "dynamic" hydrogel ink alongside other static materials. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Responsive Hydrogels for Label-Free Signal Transduction within Biosensors

    Directory of Open Access Journals (Sweden)

    Kamila Gawel

    2010-04-01

    Full Text Available Hydrogels have found wide application in biosensors due to their versatile nature. This family of materials is applied in biosensing either to increase the loading capacity compared to two-dimensional surfaces, or to support biospecific hydrogel swelling occurring subsequent to specific recognition of an analyte. This review focuses on various principles underpinning the design of biospecific hydrogels acting through various molecular mechanisms in transducing the recognition event of label-free analytes. Towards this end, we describe several promising hydrogel systems that when combined with the appropriate readout platform and quantitative approach could lead to future real-life applications.

  7. Tough and tunable adhesion of hydrogels: experiments and models

    Science.gov (United States)

    Zhang, Teng; Yuk, Hyunwoo; Lin, Shaoting; Parada, German A.; Zhao, Xuanhe

    2017-06-01

    As polymer networks infiltrated with water, hydrogels are major constituents of animal and plant bodies and have diverse engineering applications. While natural hydrogels can robustly adhere to other biological materials, such as bonding of tendons and cartilage on bones and adhesive plaques of mussels, it is challenging to achieve such tough adhesions between synthetic hydrogels and engineering materials. Recent experiments show that chemically anchoring long-chain polymer networks of tough synthetic hydrogels on solid surfaces create adhesions tougher than their natural counterparts, but the underlying mechanism has not been well understood. It is also challenging to tune systematically the adhesion of hydrogels on solids. Here, we provide a quantitative understanding of the mechanism for tough adhesions of hydrogels on solid materials via a combination of experiments, theory, and numerical simulations. Using a coupled cohesive-zone and Mullins-effect model validated by experiments, we reveal the interplays of intrinsic work of adhesion, interfacial strength, and energy dissipation in bulk hydrogels in order to achieve tough adhesions. We further show that hydrogel adhesion can be systematically tuned by tailoring the hydrogel geometry and silanization time of solid substrates, corresponding to the control of energy dissipation zone and intrinsic work of adhesion, respectively. The current work further provides a theoretical foundation for rational design of future biocompatible and underwater adhesives.

  8. PVA/atapulgite hydrogels; Hidrogeis de PVA/atapulgita

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, R.N.; Soares, G.A., E-mail: nunes@metalmat.ufrj.b [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Paranhos, C.M. [Universidade Federal de Sao Carlos (UFSCAR), SP (Brazil); Barreto, L.S. [Universidade Federal de Sergipe (UFS), Aracaju, SE (Brazil)

    2010-07-01

    PVA hydrogels can be used as wound-healing as a consequence of their biocompatibility, flexibility, etc. In order to improve mechanical resistance of wound-healing, polymeric hydrogels reinforced with clay have been studied. Among national clays, attapulgite stands out. Once it is a natural material, acid treatment can be required in order to remove impurities. In the present work, PVA hydrogels reinforced with attapulgite were produced and they were characterized by swelling behavior, XRD, DSC and traction test. Among all properties studied, hydrogels reinforced with activated attapulgite showed better mechanical resistance and Young module than the other samples. (author)

  9. Injectable Biopolymer-hydroxyapatite Hydrogels: Obtaining and their Characterization

    Directory of Open Access Journals (Sweden)

    L.B. Sukhodub

    2016-03-01

    Full Text Available Hydrogels based on hydroxyapatite (HA and Chitosan (CS with addition of sodium alginate (Alg were synthesized by in situ precipitation method. Structure, morphology, chemical and phase composition of the HA/CS and HA/CS/Alg hydrogels were characterized by TEM, FTIR and XRD. Hydrogels consist of low crystallinity calcium deficient hydroxyapatite (JCPDS 9 432, the needle-like crystallites have an average size 25 nm. The introduction of Alginate powder into HA/CS hydrogel solution demonstrate the viscosity enhancing of the HA/CS hydrogel due to polyelectrolyte reaction between Alginate and Chitosan macromolecules. Two natural polymers and partially released from hydroxyapatite Ca2+ ions formed a matrix by crosslinking the polymer macromolecules through hydroxyl, amino and carbonyl groups. These processes promote the formation of a more stable structure of HA/CS/Alg hydrogel as compared to HA/CS. The structural integrity and degradation tests have demonstrated that HA/CS/Alg1.0 saved its initial shape in 7 days of shaking in SBF solution, meanwhile for HA/CS, a structural decay was observed. The HA/CS hydrogel had completely lost its volume support after 1 day shaking in SBF. Thus, the ability of HA/CS hydrogel to maintain its shape with implantation into bone tissue defect may be enhanced with alginate addition, but alginate content more than 1 w/w % reduces the hydrogel plasticity, increases the swelling and accelerates the shape decay.

  10. Thermo-Responsive Hydrogels for Stimuli-Responsive Membranes

    Directory of Open Access Journals (Sweden)

    Evan Mah

    2013-09-01

    Full Text Available Composite membranes with stimuli-responsive properties can be made by coating a thermo-responsive hydrogel onto a micro- or macroporous support. These hydrogels undergo a temperature induced volume-phase transition, which contributes towards the composite membrane’s stimuli-responsive properties. This paper reviews research done on complimentary forms of temperature responsive “thermophilic” hydrogels, those exhibiting positive volume-phase transitions in aqueous solvent. The influences of intermolecular forces on the mechanism of phase-transition are discussed along with case examples of typical thermophilic hydrogels.

  11. Biodegradable HEMA-based hydrogels with enhanced mechanical properties.

    Science.gov (United States)

    Moghadam, Mohamadreza Nassajian; Pioletti, Dominique P

    2016-08-01

    Hydrogels are widely used in the biomedical field. Their main purposes are either to deliver biological active agents or to temporarily fill a defect until they degrade and are followed by new host tissue formation. However, for this latter application, biodegradable hydrogels are usually not capable to sustain any significant load. The development of biodegradable hydrogels presenting load-bearing capabilities would open new possibilities to utilize this class of material in the biomedical field. In this work, an original formulation of biodegradable photo-crosslinked hydrogels based on hydroxyethyl methacrylate (HEMA) is presented. The hydrogels consist of short-length poly(2-hydroxyethyl methacrylate) (PHEMA) chains in a star shape structure, obtained by introducing a tetra-functional chain transfer agent in the backbone of the hydrogels. They are cross-linked with a biodegradable N,O-dimethacryloyl hydroxylamine (DMHA) molecule sensitive to hydrolytic cleavage. We characterized the degradation properties of these hydrogels submitted to mechanical loadings. We showed that the developed hydrogels undergo long-term degradation and specially meet the two essential requirements of a biodegradable hydrogel suitable for load bearing applications: enhanced mechanical properties and low molecular weight degradation products. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1161-1169, 2016.

  12. Force-compensated hydrogel-based pH sensor

    Science.gov (United States)

    Deng, Kangfa; Gerlach, Gerald; Guenther, Margarita

    2015-04-01

    This paper presents the design, simulation, assembly and testing of a force-compensated hydrogel-based pH sensor. In the conventional deflection method, a piezoresistive pressure sensor is used as a chemical-mechanical-electronic transducer to measure the volume change of a pH-sensitive hydrogel. In this compensation method, the pH-sensitive hydrogel keeps its volume constant during the whole measuring process, independent of applied pH value. In order to maintain a balanced state, an additional thermal actuator is integrated into the close-loop sensor system with higher precision and faster dynamic response. Poly (N-isopropylacrylamide) (PNIPAAm) with 5 mol% monomer 3-acrylamido propionic acid (AAmPA) is used as the temperature-sensitive hydrogel, while poly (vinyl alcohol) with poly (acrylic acid) (PAA) serves as the pH-sensitive hydrogel. A thermal simulation is introduced to assess the temperature distribution of the whole microsystem, especially the temperature influence on both hydrogels. Following tests are detailed to verify the working functions of a sensor based on pH-sensitive hydrogel and an actuator based on temperature-sensitive hydrogel. A miniaturized prototype is assembled and investigated in deionized water: the response time amounts to about 25 min, just half of that one of a sensor based on the conventional deflection method. The results confirm the applicability of t he compensation method to the hydrogel-based sensors.

  13. Physically crosslinked-sacran hydrogel films for wound dressing application.

    Science.gov (United States)

    Wathoni, Nasrul; Motoyama, Keiichi; Higashi, Taishi; Okajima, Maiko; Kaneko, Tatsuo; Arima, Hidetoshi

    2016-08-01

    The thin hydrogel films consisting of water-swollen polymer networks can potentially be applied for biomedical fields. Recently, natural polysaccharides have great attentions to be developed as wound healing and protection. In the present study, we newly prepared and characterized a physically crosslinked-hydrogel film composed of a novel megamolecular polysaccharide sacran for wound dressing application. We successfully fabricated a physically crosslinked-sacran hydrogel film by a solvent-casting method. The thickness of a sacran hydrogel film was lower than that of a sodium alginate (Na-alginate) film. Importantly, the swollen ratio of a sacran hydrogel film in water at 24h was 19-fold, compared to initial weight. Meanwhile, a Na-alginate hydrogel film was completely broken apart after rehydration. Moreover, a sacran hydrogel film did not show any cytotoxicity on NIH3T3 cells, a murine fibroblast cell line. The in vivo skin hydration study revealed that a sacran hydrogel film significantly increased the moisture content on hairless mice skin and considerably improved wound healing ability, compared to control (non-treated), probably due to not only the moisturing effect but also the anti-inflammatory effect of sacran. These results suggest that sacran has the potential properties as a basic biomaterial in a hydrogel film for wound dressing application.

  14. Bragg grating chemical sensor with hydrogel as sensitive element

    Institute of Scientific and Technical Information of China (English)

    Xiaomei Liu(刘小梅); Shilie Zheng(郑史烈); Xianmin Zhang(章献民); Jun Cong(丛军); Kangsheng Chen(陈抗生); Jian Xu(徐坚)

    2004-01-01

    A novel fiber Bragg grating (FBG) based chemical sensor using hydrogel, a swellable polymer, as sensitive element is demonstrated. The sensing mechanism relies on the shift of Bragg wavelength due to the stress resulted from volume change of sensitive swellable hydrogel responding to the change of external environment. A polyacrylamide hydrogel fiber grating chemical sensor is made, and the experiments on its sensitivity to the salinity are performed. The sensitivity is low due to the less stress from the shrinking or swelling of hydrogels. Reducing the cross diameter of the grating through etching with hydrofluoric acid can greatly improve the sensitivity of the sensor.

  15. Tumor Growth Suppression Induced by Biomimetic Silk Fibroin Hydrogels

    Science.gov (United States)

    Yan, Le-Ping; Silva-Correia, Joana; Ribeiro, Viviana P.; Miranda-Gonçalves, Vera; Correia, Cristina; da Silva Morais, Alain; Sousa, Rui A.; Reis, Rui M.; Oliveira, Ana L.; Oliveira, Joaquim M.; Reis, Rui L.

    2016-08-01

    Protein-based hydrogels with distinct conformations which enable encapsulation or differentiation of cells are of great interest in 3D cancer research models. Conformational changes may cause macroscopic shifts in the hydrogels, allowing for its use as biosensors and drug carriers. In depth knowledge on how 3D conformational changes in proteins may affect cell fate and tumor formation is required. Thus, this study reports an enzymatically crosslinked silk fibroin (SF) hydrogel system that can undergo intrinsic conformation changes from random coil to β-sheet conformation. In random coil status, the SF hydrogels are transparent, elastic, and present ionic strength and pH stimuli-responses. The random coil hydrogels become β-sheet conformation after 10 days in vitro incubation and 14 days in vivo subcutaneous implantation in rat. When encapsulated with ATDC-5 cells, the random coil SF hydrogel promotes cell survival up to 7 days, whereas the subsequent β-sheet transition induces cell apoptosis in vitro. HeLa cells are further incorporated in SF hydrogels and the constructs are investigated in vitro and in an in vivo chick chorioallantoic membrane model for tumor formation. In vivo, Angiogenesis and tumor formation are suppressed in SF hydrogels. Therefore, these hydrogels provide new insights for cancer research and uses of biomaterials.

  16. Research on the Microstructure and Wear Resistance of the Tungsten Carbides Reinforced Composite Coating Made From Tungsten Powder and Silicon Carbide%钨粉与碳化硅为原料制备碳化钨陶瓷涂层的组织及耐磨性研究

    Institute of Scientific and Technical Information of China (English)

    任莹; 王晓燕; 陈小凡

    2013-01-01

    As a typical boride ceramics,WC ceramics have become a researched hot point because of its high melting point,good chemi cal stability,high hardness and good resistance to abrasion.The WC granule is in-situ synthesized during the reaction of the alloy.powders employing the TIG powder surfacing.The microstructure and morphology of the tungsten carbide coating is observed and analyzed.The abrasive wear performance of the coating is also studied.%碳化钨陶瓷因具有极高的熔点、高的化学稳定性、高的硬度和优异的耐磨耐蚀性,已成为近年来金属陶瓷研究的热点之一.笔者采用钨极氩弧堆焊设备,通过原料粉末之间的高温冶金反应,在堆焊过程中原位合成碳化钨金属陶瓷涂层,对所制备的涂层试样的组织结构进行了观察分析,并且研究了涂层的耐磨料的磨损性能.

  17. PVA-Sago starch hydrogel and the preliminary clinical animal study of the hydrogel

    Energy Technology Data Exchange (ETDEWEB)

    Hashim, Kamaruddin; Mohd Dahlan, Khairul Zaman [Malaysian Institute for Nuclear Technology Research, Bangi, Kajang (Malaysia); Halim, Ahmad Sukari; Md Nor, Mohd Tarmizi [Sciences University of Malaysia, School of Medical Sciences, Kerian, Kelantan (Malaysia); Yoshii, Fumio [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    2002-03-01

    Sago starch granule dissolves in hot water to form physically crosslink semi-gel structure. Polyvinyl alcohol (PVA) in aqueous solution is chemically crosslink and form hydrogel after expose to gamma or electron beam irradiation. Combination of sago starch and PVA give tremendous improvement on strength and elasticity of the gel. Adding additive such as carboxymethyl cellulose enhance the swelling or absorption property of the gel. These properties of hydrogel are important for wound dressing application. The preliminary clinical animal study on the PVA Sago hydrogel dressing shows promising results of healing process in comparison with the conventional dressing using vaseline impregnated gauze acting as control dressing. This re-confirmed by biopsy tests on the wound tissue taking during the healing process. The tests show the increasing amount of fibroblast and endothelial cells on both wounds using hydrogel and jalonet during the healing process. Also, the rate of epitheliazation is almost completed for both wounds after 10 days of dressing and the lymphocytes cell increase tremendously for the first 14 days with hydrogel dressing. (author)

  18. Wear behaviour of laser melted an ion implanted materials.

    NARCIS (Netherlands)

    Beurs, Hans de

    1988-01-01

    The emphasis in this thesis is on the development of wear resistant materials by laser melting. Furthermore, the principle aim is to search for the dislocation characteristics common to the wear process in heterogeneous materials. ... Zie: Summary

  19. Comparison of two measurement techniques for clinical wear

    DEFF Research Database (Denmark)

    Peters, M C; Delong, R; Pintado, M R

    1999-01-01

    Clinical wear of restorations is generally evaluated by marginal integrity over time. In this study, both a subjective and an objective method for wear assessment are compared, and the relative advantages and disadvantages of each are considered....

  20. Interactions between nonlinear spur gear dynamics and surface wear

    Science.gov (United States)

    Ding, Huali; Kahraman, Ahmet

    2007-11-01

    In this study, two different dynamic models, a finite elements-based deformable-body model and a simplified discrete model, and a surface wear model are combined to study the interaction between gear surface wear and gear dynamic response. The proposed dynamic gear wear model includes the influence of worn surface profiles on dynamic tooth forces and transmission error as well as the influence of dynamic tooth forces on wear profiles. This paper first introduces the nonlinear dynamic models that include gear backlash and time-varying gear mesh stiffness, and a wear model separately. It presents a comparison to experiments for validation of the dynamic models. The dynamic models are combined with the wear model to study the interaction of surface wear and dynamic behavior in both linear and nonlinear response regimes. At the end, several sets of simulation results are used to demonstrate the two-way relationship between nonlinear gear dynamics and surface wear.

  1. Evaluation and silicon nitride internal combustion engine components. Final report, Phase I

    Energy Technology Data Exchange (ETDEWEB)

    Voldrich, W. [Allied-Signal Aerospace Co., Torrance, CA (United States). Garrett Ceramic Components Div.

    1992-04-01

    The feasibility of silicon nitride (Si{sub 3}N{sub 4}) use in internal combustion engines was studied by testing three different components for wear resistance and lower reciprocating mass. The information obtained from these preliminary spin rig and engine tests indicates several design changes are necessary to survive high-stress engine applications. The three silicon nitride components tested were valve spring retainers, tappet rollers, and fuel pump push rod ends. Garrett Ceramic Components` gas-pressure sinterable Si{sub 3}N{sub 4} (GS-44) was used to fabricate the above components. Components were final machined from densified blanks that had been green formed by isostatic pressing of GS-44 granules. Spin rig testing of the valve spring retainers indicated that these Si{sub 3}N{sub 4} components could survive at high RPM levels (9,500) when teamed with silicon nitride valves and lower spring tension than standard titanium components. Silicon nitride tappet rollers showed no wear on roller O.D. or I.D. surfaces, steel axles and lifters; however, due to the uncrowned design of these particular rollers the cam lobes indicated wear after spin rig testing. Fuel pump push rod ends were successful at reducing wear on the cam lobe and rod end when tested on spin rigs and in real-world race applications.

  2. ERRATUM: Work smart, wear your hard hat

    CERN Multimedia

    2003-01-01

    An error appeared in the article «Work smart, wear your hard hat» published in Weekly Bulletin 27/2003, page 5. The impact which pierced a hole in the hard hat worn by Gerd Fetchenhauer was the equivalent of a box weighing 5 kg and not 50 kg.

  3. Reciprocating wear in a steam environment

    Energy Technology Data Exchange (ETDEWEB)

    Brown, L.J.; Gee, M.G. [National Physical Laboratory, Teddington, Middlesex (United Kingdom)

    2010-07-01

    Tests to simulate the wear between sliding components in steam power plant have been performed using a low frequency wear apparatus at elevated temperatures under static load, at ambient pressure, in a steam environment. The apparatus was modified to accept a novel method of steam delivery. The materials tested were pre-exposed in a flowing steam furnace at temperature for either 500 or 3000 hours to provide some simulation of long term ageing. The duration of each wear test was 50 hours and tests were also performed on as-received material for comparison purposes. Data has been compared with results of tests performed on non-oxidised material for longer durations and also on tests without steam to examine the effect of different environments. Data collected from each test consists of mass change, stub height measurement and friction coefficient as well as visual inspection of the wear track. Within this paper, it is reported that both pre-ageing and the addition of steam during testing clearly influence the friction between material surfaces. (orig.)

  4. Saliva parameters and erosive wear in adolescents

    NARCIS (Netherlands)

    Zwier, N.; Huysmans, M.C.D.N.J.M.; Jager, D.H.J.; Ruben, J.; Bronkhorst, E.M.; Truin, G.J.

    2013-01-01

    The aim of this study was to investigate the relationship between several parameters of saliva and erosive wear in adolescents. (Un-)stimulated saliva was collected from 88 adolescents with erosion and 49 controls (age 16 ± 1 years). Flow rate, pH and buffer capacity were determined immediately.

  5. Saliva Parameters and Erosive Wear in Adolescents

    NARCIS (Netherlands)

    Zwier, N.; Huysmans, M. C. D. N. J. M.; Jager, D. H. J.; Ruben, J.; Bronkhorst, E. M.; Truin, G. J.

    2013-01-01

    The aim of this study was to investigate the relationship between several parameters of saliva and erosive wear in adolescents. (Un-)stimulated saliva was collected from 88 adolescents with erosion and 49 controls (age 16 +/- 1 years). Flow rate, pH and buffer capacity were determined immediately.

  6. Healthy Contact Lens Wear and Care

    Centers for Disease Control (CDC) Podcasts

    2014-02-04

    In this podcast, CDC’s Dr. Jennifer Cope explains some basic steps for proper wear and care of soft contact lenses.  Created: 2/4/2014 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 2/4/2014.

  7. Friction and wear of human hair fibres

    Science.gov (United States)

    Bowen, James; Johnson, Simon A.; Avery, Andrew R.; Adams, Michael J.

    2016-06-01

    An experimental study of the tribological properties of hair fibres is reported, and the effect of surface treatment on the evolution of friction and wear during sliding. Specifically, orthogonally crossed fibre/fibre contacts under a compressive normal load over a series of 10 000 cycle studies are investigated. Reciprocating sliding at a velocity of 0.4 mm s-1, over a track length of 0.8 mm, was performed at 18 °C and 40%-50% relative humidity. Hair fibres retaining their natural sebum were studied, as well as those stripped of their sebum via hexane cleaning, and hair fibres conditioned using a commercially available product. Surface topography modifications resulting from wear were imaged using scanning electron microscopy and quantified using white light interferometry. Hair fibres that presented sebum or conditioned product at the fibre/fibre junction exhibited initial coefficients of friction at least 25% lower than those that were cleaned with hexane. Coefficients of friction were observed to depend on the directionality of sliding for hexane cleaned hair fibres after sufficient wear cycles that cuticle lifting was present, typically on the order 1000 cycles. Cuticle flattening was observed for fibre/fibre junctions exposed to 10 mN compressive normal loads, whereas loads of 100 mN introduced substantial cuticle wear and fibre damage.

  8. Tribology: Friction, lubrication, and wear technology

    Science.gov (United States)

    Blau, Peter J.

    1993-01-01

    The topics are presented in viewgraph form and include the following: introduction and definitions of terms; friction concepts; lubrication technology concepts; wear technology concepts; and tribological transitions. This document is designed for educators who seek to teach these concepts to their students.

  9. Powdered Hexagonal Boron Nitride Reducing Nanoscale Wear

    Science.gov (United States)

    Chkhartishvili, L.; Matcharashvili, T.; Esiava, R.; Tsagareishvili, O.; Gabunia, D.; Margiev, B.; Gachechiladze, A.

    2013-05-01

    A morphology model is suggested for nano-powdered hexagonal boron nitride that can serve as an effective solid additive to liquid lubricants. It allows to estimate the specific surface, that is a hard-to-measure parameter, based on average size of powder particles. The model can be used also to control nanoscale wear processes.

  10. Corrosive wear. Evaluation of wear and corrosive resistant materials; Noetningskorrosion. Utvaerdering av noetnings- och korrosionsbestaendiga material

    Energy Technology Data Exchange (ETDEWEB)

    Persson, H.; Hjertsen, D.; Waara, P.; Prakash, B.; Hardell, J.

    2007-12-15

    With a new purchase of a waste conveyer screw at hand, for the 'A-warehouse' at the combined power and heating plant at E.ON Norrkoeping, the request for improved construction materials was raised. The previous screw required maintenance with very short intervals due to the difficult operation conditions. With the new screw the expectation is to manage 6 months of operation without interruption. The environment for the screw has two main components that sets the demand on the materials, on one hand the corrosive products that comes along and which forms at digestion of the waste and on the other hand the abrasive content in the waste. The term of the mechanism is wear-corrosion and can give considerably higher material loss than the two mechanisms wear and corrosion separately. Combination of a strong corrosive environment together with extensive wear is something that we today have limited knowledge about. The overall objective of the project has been to establish better wear and corrosive resistant construction materials for a waste conveyer screw that will lead to reduced operational disturbance costs. The evaluation has been performed in both controlled laboratory environments and in field tests, which has given us a better understanding of what materials are more suitable in this tough environment and has given us a tool for future predictions of the wear rate of the different material. The new conveyer screw, installed in February 2007 and with which the field test have been performed, has considerably reduced the wear of the construction and the target of 6 month maintenance-free operation is met with this screw for all the evaluated materials. The wear along the screw varies very much and with a clear trend for all the materials to increase towards the feeding direction of the screw. As an example, the wear plate SS2377 (stainless duplex steel) has a useful life at the most affected areas that is calculated to be 1077 days of operation with the

  11. Structurally Integrated Coatings for Wear and Corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Beardsley, M. Brad; Sebright, Jason L.

    2008-11-18

    Wear and corrosion of structures cuts across industries and continues to challenge materials scientists and engineers to develop cost effective solutions. Industries typically seek mature technologies that can be implemented for production with rapid or minimal development and have little appetite for the longer-term materials research and development required to solve complex problems. The collaborative work performed in this project addressed the complexity of this problem in a multi-year program that industries would be reluctant to undertake without government partnership. This effort built upon the prior development of Advanced Abrasion Resistant Materials conduct by Caterpillar Inc. under DOE Cooperative Agreement No. DE-FC26-01NT41054. In this referenced work, coatings were developed that exhibited significant wear life improvements over standard carburized heat treated steel in abrasive wear applications. The technology used in this referenced work, arc lamp fusing of thermal spray coatings, was one of the primary technical paths in this work effort. In addition to extending the capability of the coating technology to address corrosion issues, additional competitive coating technologies were evaluated to insure that the best technology was developed to meet the goals of the program. From this, plasma transferred arc (PTA) welding was selected as the second primary technology that was investigated. Specifically, this project developed improved, cost effective surfacing materials and processes for wear and corrosion resistance in both sliding and abrasive wear applications. Materials with wear and corrosion performance improvements that are 4 to 5 times greater than heat treated steels were developed. The materials developed were based on low cost material systems utilizing ferrous substrates and stainless steel type matrix with hard particulates formed from borides and carbides. Affordability was assessed against other competing hard surfacing or coating

  12. STUDY ON WEAR AND DESTRUCTION OF HOB IN GEAR HOBBING

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    The wear and destruction appearances of hobs are researched. The reasons of the wear and destruction of hobare analyzed. And the influence of the change of the hobbing force and the hobbing temperature on the wear and destruc-tion of hob in gear hobbing is also analyzed. In gear hobbing, the main wear mechanisms are adhesion and ploughingwhen cutting the 20CrMnTi gear using W 18Cr4V high-speed steel hob.

  13. New synthesizing feature parameter of wear particles image

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    This paper outlines the application of wavelet analysis method to computering wear par-ticles image processing and introduces the concept of grain parameter for wear particle imagebased on statistical feature parameters. The feature of wear particles image can be obtained fromthe wavelet decomposition and the statistics analysis. Test results showed that grain parametercan be used as a synthesizing feature parameter for wear particle image.

  14. A panorama of tooth wear during the medieval period.

    Science.gov (United States)

    Esclassan, Rémi; Hadjouis, Djillali; Donat, Richard; Passarrius, Olivier; Maret, Delphine; Vaysse, Frédéric; Crubézy, Eric

    2015-01-01

    Tooth wear is a natural phenomenon and a universal occurrence that has existed from the origin of humankind and depends on the way of life, especially diet. Tooth wear was very serious in ancient populations up to the medieval period. The aim of this paper is to present a global view of tooth wear in medieval times in Europe through different parameters: scoring systems, quantity and direction of wear, gender, differences between maxilla and mandible, relations with diet, caries, tooth malpositions and age.

  15. An On-line Ferrograph for Monitoring Machine Wear

    Institute of Scientific and Technical Information of China (English)

    L(U) Xiao-jun; JING Min-qing; XIE You-bai

    2005-01-01

    In order to improve an on-line ferrograph, this paper simulates a three dimensional magnetic field distribution of an electromagnet, builds a sinking motion model of a wear particle, and investigates the motion law of wear particles under two different conditions. Both numeric results and experimental results show that the on-line ferrograph is capable of monitoring machine wear conditions by measuring the concentration and size distribution of wear particles in lubricating oil.

  16. Wear numbers for ball cup and journal bearings

    OpenAIRE

    Ligterink, D.J.; Moes, H.

    1980-01-01

    A wear number is defined for ball cup bearings and for journal bearings where the cup and the cylindrical bearing are made of soft material. This dimensionless wear number provides a relation between the following five quantities: the radius of the ball or the length of the journal bearing in millimetres, the wear modulus in newtons per square millimetre, the maximum wear depth rate of the cup or the cylindrical bearing in millimetres per second, the force between the mating surfaces in newto...

  17. Sliding Wear and Fretting Wear of DLC-Based, Functionally Graded Nanocomposite Coatings

    Science.gov (United States)

    Miyoshi, K.; Pohlchuck, B.; Street, Kenneth W.; Zabinski, J. S.; Sanders, J. H.; Voevodin, A. a.; Wu, R. L. C.

    1999-01-01

    Improving the tribological functionality of diamondlike carbon (DLC) films--developing, good wear resistance, low friction, and high load-carrying capacity-was the aim of this investigation. Nanocomposite coatings consisting of an amorphous DLC (a-DLC) top layer and a functionally graded titanium-titanium carbon-diamondlike carbon (Ti-Ti(sub x) C(sub y)-DLC) underlayer were produced on AISI 440C stainless steel substrates by the hybrid technique of magnetron sputtering and pulsed-laser deposition. The resultant DLC films were characterized by Raman spectroscopy, scanning electron microscopy, and surface profilometry. Two types of wear experiment were conducted in this investioation: sliding friction experiments and fretting wear experiments. Unidirectional ball-on-disk sliding friction experiments were conducted to examine the wear behavior of an a-DLC/Ti-Ti(sub x) C(sub y)-DLC-coated AISI 440C stainless steel disk in sliding contact with a 6-mm-diameter AISI 440C stainless steel ball in ultrahigh vacuum, dry nitrogen, and humid air. Although the wear rates for both the coating and ball were low in all three environments, the humid air and dry nitrogen caused mild wear with burnishing, in the a-DLC top layer, and the ultrahigh vacuum caused relatively severe wear with brittle fracture in both the a-DLC top layer and the Ti-Ti(sub x) C(sub y)-DLC underlayer. For reference, amorphous hydrogenated carbon (H-DLC) films produced on a-DLC/Ti-Ti(sub x) C(sub y)-DLC nanocomposite coatings by using an ion beam were also examined in the same manner. The H-DLC films markedly reduced friction even in ultrahigh vacuum without sacrificing wear resistance. The H-DLC films behaved much like the a-DLC/Ti-Ti(sub x) C(sub y)-DLC nanocomposite coating in dry nitrogen and humid air, presenting low friction and low wear. Fretting wear experiments were conducted in humid air (approximately 50% relative humidity) at a frequency of 80 Hz and an amplitude of 75 micron on an a

  18. Poly(N-vinylpyrrolidone) hydrogels. Pt. 2; Hydrogel composites as wound dressing for tropical environment

    Energy Technology Data Exchange (ETDEWEB)

    Hilmy, N.; Darwis, D.; Hardiningsih, L. (Center for the Application of Isotopes and Radiation, BATAN, Jakarta (Indonesia))

    The effects of irradiation on hydration and other properties of poly(vinylpyrrolidone) (PVP) hydrogel composites have been investigated. The aqueous solution of vinylpyrrolidone (VP) 10 wt % was mixed with several additives such as agar and polyethylene glycol (PEG). The solution was then irradiated with gamma rays from a Cobalt-60 source at room temperature. Several parameters such as elongation at break (EB), tensile strength (TS), degree of swelling (DS), water vapor transmission rate (WVTR), equilibrium water content (EWC), microbial growth and penetration tests, and water activity (Aw) were analysed at room temperature of 29 [+-] 2[sup o]C humidity of 80 [+-] 10%. Such hydrogel membranes exhibit the following properties: they are elastic, transparent, flexible, impermeable for bacteria. They absorb a high capacity of water, attach to healthy skin but not to the wound and they are easy to remove. These properties of the hydrogel membranes allow application as a wound dressing in a tropical environment. (author).

  19. Piezoresistive Chemical Sensors Based on Functionalized Hydrogels

    Directory of Open Access Journals (Sweden)

    Margarita Guenther

    2014-06-01

    Full Text Available Thin films of analyte-specific hydrogels were combined with microfabricated piezoresistive pressure transducers to obtain chemomechanical sensors that can serve as selective biochemical sensors for a continuous monitoring of metabolites. The gel swelling pressure has been monitored in simulated physiological solutions by means of the output signal of piezoresistive sensors. The interference by fructose, human serum albumin, pH, and ionic concentration on glucose sensing was studied. With the help of a database containing the calibration curves of the hydrogel-based sensors at different values of pH and ionic strength, the corrected values of pH and glucose concentration were determined using a novel calibration algorithm.

  20. Protease-degradable electrospun fibrous hydrogels

    Science.gov (United States)

    Wade, Ryan J.; Bassin, Ethan J.; Rodell, Christopher B.; Burdick, Jason A.

    2015-03-01

    Electrospun nanofibres are promising in biomedical applications to replicate features of the natural extracellular matrix (ECM). However, nearly all electrospun scaffolds are either non-degradable or degrade hydrolytically, whereas natural ECM degrades proteolytically, often through matrix metalloproteinases. Here we synthesize reactive macromers that contain protease-cleavable and fluorescent peptides and are able to form both isotropic hydrogels and electrospun fibrous hydrogels through a photoinitiated polymerization. These biomimetic scaffolds are susceptible to protease-mediated cleavage in vitro in a protease dose-dependent manner and in vivo in a subcutaneous mouse model using transdermal fluorescent imaging to monitor degradation. Importantly, materials containing an alternate and non-protease-cleavable peptide sequence are stable in both in vitro and in vivo settings. To illustrate the specificity in degradation, scaffolds with mixed fibre populations support selective fibre degradation based on individual fibre degradability. Overall, this represents a novel biomimetic approach to generate protease-sensitive fibrous scaffolds for biomedical applications.

  1. Biomimetic Membrane Arrays on Cast Hydrogel Supports

    DEFF Research Database (Denmark)

    Roerdink-Lander, Monique; Ibragimova, Sania; Rein Hansen, Christian;

    2011-01-01

    Lipid bilayers are intrinsically fragile and require mechanical support in technical applications based on biomimetic membranes. Tethering the lipid bilayer membranes to solid substrates, either directly through covalent or ionic substrate−lipid links or indirectly on substrate-supported cushions......, provides mechanical support but at the cost of small molecule transport through the membrane−support sandwich. To stabilize biomimetic membranes while allowing transport through a membrane−support sandwich, we have investigated the feasibility of using an ethylene tetrafluoroethylene (ETFE......)/hydrogel sandwich as the support. The sandwich is realized as a perforated surface-treated ETFE film onto which a hydrogel composite support structure is cast. We report a simple method to prepare arrays of lipid bilayer membranes with low intrinsic electrical conductance on the highly permeable, self...

  2. Using hydrogels in microscopy: A tutorial.

    Science.gov (United States)

    Flood, Peter; Page, Henry; Reynaud, Emmanuel G

    2016-05-01

    Sample preparation for microscopy is a crucial step to ensure the best experimental outcome. It often requires the use of specific mounting media that have to be tailored to not just the sample but the chosen microscopy technique. The media must not damage the sample or impair the optical path, and may also have to support the correct physiological function/development of the sample. For decades, researchers have used embedding media such as hydrogels to maintain samples in place. Their ease of use and transparency has promoted them as mainstream mounting media. However, they are not as straightforward to implement as assumed. They can contain contaminants, generate forces on the sample, have complex diffusion and structural properties that are influenced by multiple factors and are generally not designed for microscopy in mind. This short review will discuss the advantages and disadvantages of using hydrogels for microscopy sample preparation and highlight some of the less obvious problems associated with the area.

  3. Preparation of Polyphosphazene Hydrogels for Enzyme Immobilization

    Directory of Open Access Journals (Sweden)

    Yue-Cheng Qian

    2014-07-01

    Full Text Available We report on the synthesis and application of a new hydrogel based on a methacrylate substituted polyphosphazene. Through ring-opening polymerization and nucleophilic substitution, poly[bis(methacrylatephosphazene] (PBMAP was successfully synthesized from hexachlorocyclotriphosphazene. By adding PBMAP to methacrylic acid solution and then treating with UV light, we could obtain a cross-linked polyphosphazene network, which showed an ultra-high absorbency for distilled water. Lipase from Candida rugosa was used as the model lipase for entrapment immobilization in the hydrogel. The influence of methacrylic acid concentration on immobilization efficiency was studied. Results showed that enzyme loading reached a maximum of 24.02 mg/g with an activity retention of 67.25% when the methacrylic acid concentration was 20% (w/w.

  4. Hydrogels for central nervous system therapeutic strategies.

    Science.gov (United States)

    Russo, Teresa; Tunesi, Marta; Giordano, Carmen; Gloria, Antonio; Ambrosio, Luigi

    2015-12-01

    The central nervous system shows a limited regenerative capacity, and injuries or diseases, such as those in the spinal, brain and retina, are a great problem since current therapies seem to be unable to achieve good results in terms of significant functional recovery. Different promising therapies have been suggested, the aim being to restore at least some of the lost functions. The current review deals with the use of hydrogels in developing advanced devices for central nervous system therapeutic strategies. Several approaches, involving cell-based therapy, delivery of bioactive molecules and nanoparticle-based drug delivery, will be first reviewed. Finally, some examples of injectable hydrogels for the delivery of bioactive molecules in central nervous system will be reported, and the key features as well as the basic principles in designing multifunctional devices will be described.

  5. Lubrication of metal-on-metal hip joints: the effect of protein content and load on film formation and wear.

    Science.gov (United States)

    Myant, C; Underwood, R; Fan, J; Cann, P M

    2012-02-01

    Lubricant films were measured for a series of bovine serum and protein containing (albumin, globulin) saline solutions for CoCrMo femoral component sliding against a glass disc. Central film thickness was measured by optical interferometry as a function of time (constant mean speed: 0 and 10 mm/s) and variable mean speed (0-50 mm/s). The effect of load (5-20 N) on film thickness was also studied. The development of the wear scar on the CoCrMo surface was monitored by measuring the width of the contact zone during the film thickness tests. The results showed film thickness increased with time for both the static and sliding tests. Films formed in the static, loaded test were typically in the range of 3-40 nm. The globulin containing solutions formed the thickest films. In the sliding tests a wear scar rapidly formed on the implant component for the bovine serum and albumin fluids, negligible wear was observed for the globulin solutions. Film thickness increased with sliding time for all test solutions and was much greater than predicted by isoviscous EHL models. The film increase was found to correlate with increasing wear scar size and thus decreasing contact pressure. A new lubricating mechanism is proposed whereby during sliding the fluid undergoes bulk phase separation rheology, so that an elevated protein phase forms in the inlet zone. This protein phase is a high-viscosity biphasic matrix, which is periodically entrained into the contact forming a thick protective hydro-gel film. One of the main findings of this study is that film thickness was very sensitive to load; to a much greater extent than predicted by EHL models. Thus film formation in MoM hip joints is very susceptible to high contact pressures which might be due to implant misalignment and edge-loading.

  6. Microstructure and Wear Resistance of Laser Clad Cobalt-Based Alloy/SiCp Composite Coating

    Institute of Scientific and Technical Information of China (English)

    LI Ming-xi; SI Song-hua; HE Yi-zhu; SUN Guo-xiong

    2004-01-01

    The SiCp (20 %) reinforced cobalt-based alloy composite coatings deposited by laser cladding on IF steel were introduced. The microstructure across the whole section of such coatings was examined using optical microscope, scanning electron microscope (SEM) and X-ray diffractometer (XRD), and the wear resistance of the coatings was measured by MM-200 type wear testing machine. The results show that the SiCp is completely dissolved during laser cladding and the primary phase in the coatings is γ-Co. The other phases, such as Si2W, CoWSi, Cr3Si and CoSi2, are formed by carbon, silicon reacting with other elements existing in the melting pool. There are various crystallization morphologies in different zones, such as planar crystallization at the interface, followed by cellular and dendrite crystallization from interface to the surface. The direction of solidification changes from one direction perpendicular to interface to multi-directions at the central and upper regions of the clad. The wear resistance of the clad is improved by adding SiCp.

  7. Facile Use of Cationic Hydrogel Particles for Surface Modification of Planar Substrates Toward Multifunctional Neural Permissive Surfaces: An in Vitro Investigation.

    Science.gov (United States)

    Morin, Emily A; Tang, Shuangcheng; Rogers, Katie Lou; He, Wei

    2016-03-02

    Synthetic materials such as silicon have been commonly used for neural interfacing applications but are intrinsically noninteractive with neurons. Here, a facile approach has been developed to integrate both chemical and topographical cues to impart neural permissiveness for such materials. The approach simply exploits the basic phenomenon of electrostatically driven adsorption of colloidal particles onto a solid material and applies it to a cationic hydrogel particle system that we have developed recently based on "click" reaction of epoxide and amine. The particle adsorption process can be tuned by varying the adsorption time and the concentration of the original colloidal suspension, both of which directly control the surface densities of the adsorbed hydrogel particles. Using the PC12 cell line and primary cortical neurons derived from chick embryo, we demonstrate that the particle-adsorbed surface readily supports robust cell adhesion and differentiation. Although the extent of neural permissiveness exhibited by such particle-adsorbed surface was comparable to the cationic polyethylenimine-coated control surface, the adsorbed hydrogel particles offer a unique reservoir function to the modified surface that is unparalleled by the control. The successful loading of hydrophobic dye of nile red to the surface adsorbed hydrogel particles indicates that the modified surface not only provides physical support of neurons, but also can be explored in the future to exert localized therapeutic actions favorable for neural interfacing.

  8. Enzymatic regulation of functional vascular networks using gelatin hydrogels.

    Science.gov (United States)

    Chuang, Chia-Hui; Lin, Ruei-Zeng; Tien, Han-Wen; Chu, Ya-Chun; Li, Yen-Cheng; Melero-Martin, Juan M; Chen, Ying-Chieh

    2015-06-01

    To manufacture tissue engineering-based functional tissues, scaffold materials that can be sufficiently vascularized to mimic the functionality and complexity of native tissues are needed. Currently, vascular network bioengineering is largely carried out using natural hydrogels as embedding scaffolds, but most natural hydrogels have poor mechanical stability and durability, factors that critically limit their widespread use. In this study, we examined the suitability of gelatin-phenolic hydroxyl (gelatin-Ph) hydrogels that can be enzymatically crosslinked, allowing tuning of the storage modulus and the proteolytic degradation rate, for use as injectable hydrogels to support the human progenitor cell-based formation of a stable and mature vascular network. Porcine gelatin-Ph hydrogels were found to be cytocompatible with human blood-derived endothelial colony-forming cells and white adipose tissue-derived mesenchymal stem cells, resulting in >87% viability, and cell proliferation and spreading could be modulated by using hydrogels with different proteolytic degradability and stiffness. In addition, gelatin was extracted from mouse dermis and murine gelatin-Ph hydrogels were prepared. Importantly, implantation of human cell-laden porcine or murine gelatin-Ph hydrogels into immunodeficient mice resulted in the rapid formation of functional anastomoses between the bioengineered human vascular network and the mouse vasculature. Furthermore, the degree of enzymatic crosslinking of the gelatin-Ph hydrogels could be used to modulate cell behavior and the extent of vascular network formation in vivo. Our report details a technique for the synthesis of gelatin-Ph hydrogels from allogeneic or xenogeneic dermal skin and suggests that these hydrogels can be used for biomedical applications that require the formation of microvascular networks, including the development of complex engineered tissues.

  9. Severe tooth wear: European consensus statement on management guidelines

    DEFF Research Database (Denmark)

    Loomans, Bas AC; Opdam, Niek JM; Attin, Thomas

    2017-01-01

    This paper reports a European expert consensus statement on guidelines for the management of severe tooth wear. It focuses on the definition of physiological versus pathological tooth wear and recommends diagnosis, monitoring and counseling to define the activity of the wear. Restorative...

  10. 16 CFR 423.6 - Textile wearing apparel.

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Textile wearing apparel. 423.6 Section 423.6 Commercial Practices FEDERAL TRADE COMMISSION TRADE REGULATION RULES CARE LABELING OF TEXTILE WEARING APPAREL AND CERTAIN PIECE GOODS AS AMENDED § 423.6 Textile wearing apparel. This section applies to...

  11. A nanometric cushion for enhancing scratch and wear resistance of hard films.

    Science.gov (United States)

    Gotlib-Vainshtein, Katya; Girshevitz, Olga; Sukenik, Chaim N; Barlam, David; Cohen, Sidney R

    2014-01-01

    Scratch resistance and friction are core properties which define the tribological characteristics of materials. Attempts to optimize these quantities at solid surfaces are the subject of intense technological interest. The capability to modulate these surface properties while preserving both the bulk properties of the materials and a well-defined, constant chemical composition of the surface is particularly attractive. We report herein the use of a soft, flexible underlayer to control the scratch resistance of oxide surfaces. Titania films of several nm thickness are coated onto substrates of silicon, kapton, polycarbonate, and polydimethylsiloxane (PDMS). The scratch resistance measured by scanning force microscopy is found to be substrate dependent, diminishing in the order PDMS, kapton/polycarbonate, Si/SiO2. Furthermore, when PDMS is applied as an intermediate layer between a harder substrate and titania, marked improvement in the scratch resistance is achieved. This is shown by quantitative wear tests for silicon or kapton, by coating these substrates with PDMS which is subsequently capped by a titania layer, resulting in enhanced scratch/wear resistance. The physical basis of this effect is explored by means of Finite Element Analysis, and we suggest a model for friction reduction based on the "cushioning effect" of a soft intermediate layer.

  12. Controlled Delivery of Vancomycin via Charged Hydrogels.

    Science.gov (United States)

    Gustafson, Carl T; Boakye-Agyeman, Felix; Brinkman, Cassandra L; Reid, Joel M; Patel, Robin; Bajzer, Zeljko; Dadsetan, Mahrokh; Yaszemski, Michael J

    2016-01-01

    Surgical site infection (SSI) remains a significant risk for any clean orthopedic surgical procedure. Complications resulting from an SSI often require a second surgery and lengthen patient recovery time. The efficacy of antimicrobial agents delivered to combat SSI is diminished by systemic toxicity, bacterial resistance, and patient compliance to dosing schedules. We submit that development of localized, controlled release formulations for antimicrobial compounds would improve the effectiveness of prophylactic surgical wound antibiotic treatment while decreasing systemic side effects. Our research group developed and characterized oligo(poly(ethylene glycol)fumarate)/sodium methacrylate (OPF/SMA) charged copolymers as biocompatible hydrogel matrices. Here, we report the engineering of this copolymer for use as an antibiotic delivery vehicle in surgical applications. We demonstrate that these hydrogels can be efficiently loaded with vancomycin (over 500 μg drug per mg hydrogel) and this loading mechanism is both time- and charge-dependent. Vancomycin release kinetics are shown to be dependent on copolymer negative charge. In the first 6 hours, we achieved as low as 33.7% release. In the first 24 hours, under 80% of total loaded drug was released. Further, vancomycin release from this system can be extended past four days. Finally, we show that the antimicrobial activity of released vancomycin is equivalent to stock vancomycin in inhibiting the growth of colonies of a clinically derived strain of methicillin-resistant Staphylococcus aureus. In summary, our work demonstrates that OPF/SMA hydrogels are appropriate candidates to deliver local antibiotic therapy for prophylaxis of surgical site infection.

  13. Controlled Angiogenesis in Peptide Nanofiber Composite Hydrogels

    OpenAIRE

    Wickremasinghe, Navindee C.; Kumar, Vivek A.; Shi, Siyu; Hartgerink, Jeffrey D.

    2015-01-01

    Multidomain peptide (MDP) nanofibers create scaffolds that can present bioactive cues to promote biological responses. Orthogonal self-assembly of MDPs and growth-factor-loaded liposomes generate supramolecular composite hydrogels. These composites can act as delivery vehicles with time-controlled release. Here we examine the controlled release of placental growth factor-1 (PlGF-1) for its ability to induce angiogenic responses. PlGF-1 was loaded either in MDP matrices or within liposomes bou...

  14. Controlled Delivery of Vancomycin via Charged Hydrogels.

    Directory of Open Access Journals (Sweden)

    Carl T Gustafson

    Full Text Available Surgical site infection (SSI remains a significant risk for any clean orthopedic surgical procedure. Complications resulting from an SSI often require a second surgery and lengthen patient recovery time. The efficacy of antimicrobial agents delivered to combat SSI is diminished by systemic toxicity, bacterial resistance, and patient compliance to dosing schedules. We submit that development of localized, controlled release formulations for antimicrobial compounds would improve the effectiveness of prophylactic surgical wound antibiotic treatment while decreasing systemic side effects. Our research group developed and characterized oligo(poly(ethylene glycolfumarate/sodium methacrylate (OPF/SMA charged copolymers as biocompatible hydrogel matrices. Here, we report the engineering of this copolymer for use as an antibiotic delivery vehicle in surgical applications. We demonstrate that these hydrogels can be efficiently loaded with vancomycin (over 500 μg drug per mg hydrogel and this loading mechanism is both time- and charge-dependent. Vancomycin release kinetics are shown to be dependent on copolymer negative charge. In the first 6 hours, we achieved as low as 33.7% release. In the first 24 hours, under 80% of total loaded drug was released. Further, vancomycin release from this system can be extended past four days. Finally, we show that the antimicrobial activity of released vancomycin is equivalent to stock vancomycin in inhibiting the growth of colonies of a clinically derived strain of methicillin-resistant Staphylococcus aureus. In summary, our work demonstrates that OPF/SMA hydrogels are appropriate candidates to deliver local antibiotic therapy for prophylaxis of surgical site infection.

  15. Insitu grafting silica nanoparticles reinforced nanocomposite hydrogels

    Science.gov (United States)

    Yang, Jun; Han, Chun-Rui; Duan, Jiu-Fang; Xu, Feng; Sun, Run-Cang

    2013-10-01

    Highly flexible nanocomposite hydrogels were prepared by using silica nanoparticles (SNPs) as fillers and multi-functional cross-links to graft hydrophilic poly(acrylic acid) (PAA) by free radical polymerization from an aqueous solution. The SNPs were collected by neighboring polymer chains and dispersed uniformly within a PAA matrix. The mechanical properties of the nanocomposite hydrogels were tailored by the concentration of SNPs according to the percolation model. It was proposed that covalent bonds of adsorbed chains on the filler surface resulted in the formation of a shell of an immobilized glassy layer and trapped entanglements, where the glassy polymer layer greatly enhanced the elastic modulus and the release of trapped entanglements at deformation contributed to the viscoelastic properties.Highly flexible nanocomposite hydrogels were prepared by using silica nanoparticles (SNPs) as fillers and multi-functional cross-links to graft hydrophilic poly(acrylic acid) (PAA) by free radical polymerization from an aqueous solution. The SNPs were collected by neighboring polymer chains and dispersed uniformly within a PAA matrix. The mechanical properties of the nanocomposite hydrogels were tailored by the concentration of SNPs according to the percolation model. It was proposed that covalent bonds of adsorbed chains on the filler surface resulted in the formation of a shell of an immobilized glassy layer and trapped entanglements, where the glassy polymer layer greatly enhanced the elastic modulus and the release of trapped entanglements at deformation contributed to the viscoelastic properties. Electronic supplementary information (ESI) available: FTIR spectra of SNP after silane treatment, dynamic oscillatory shear measurements as a function of frequency, constrained polymer chain analysis by a change in the peak height in loss factor spectra, molecular weight of grafted chains at different stages of gelation, prediction of the SNP reinforcing mechanism in the

  16. Connections matter: channeled hydrogels to improve vascularization

    Directory of Open Access Journals (Sweden)

    Severin eMuehleder

    2014-11-01

    Full Text Available The use of cell-laden hydrogels to engineer soft tissue has been emerging within the past years. Despite several newly developed and sophisticated techniques to encapsulate different cell types the importance of vascularization of the engineered constructs is often underestimated. As a result, cell death within a construct leads to impaired function and inclusion of the implant. Here, we discuss the fabrication of hollow channels within hydrogels as a promising strategy to facilitate vascularization. Furthermore, we present an overview on the feasible use of removable spacers, 3D laser- and planar processing strategies to create channels within hydrogels. The implementation of these structures promotes control over cell distribution and increases oxygen transport and nutrient supply in vitro. However, many studies lack the use of endothelial cells in their approaches leaving out an important factor to enhance vessel ingrowth and anastomosis formation upon implantation. In addition, the adequate endothelial cell type needs to be considered to make these approaches bridge the gap to in vivo applications.

  17. Chitosan Hydrogel Structure Modulated by Metal Ions

    Science.gov (United States)

    Nie, Jingyi; Wang, Zhengke; Hu, Qiaoling

    2016-10-01

    As one of the most important polysaccharide, chitosan (CS) has generated a great deal of interest for its desirable properties and wide applications. In the utilization of CS materials, hydrogel is a major and vital branch. CS has the ability to coordinate with many metal ions by a chelation mechanism. While most researchers focused on the applications of complexes between CS and metal ions, the complexes can also influence gelation process and structure of CS hydrogel. In the present work, such influence was studied with different metal ions, revealing two different kinds of mechanisms. Strong affinity between CS and metal ions leads to structural transition from orientation to multi-layers, while weak affinity leads to composite gel with in-situ formed inorganic particles. The study gave a better understanding of the gelation mechanism and provided strategies for the modulation of hydrogel morphology, which benefited the design of new CS-based materials with hierarchical structure and facilitated the utilization of polysaccharide resources.

  18. Engineering hydrogels as extracellular matrix mimics.

    Science.gov (United States)

    Geckil, Hikmet; Xu, Feng; Zhang, Xiaohui; Moon, SangJun; Demirci, Utkan

    2010-04-01

    Extracellular matrix (ECM) is a complex cellular environment consisting of proteins, proteoglycans, and other soluble molecules. ECM provides structural support to mammalian cells and a regulatory milieu with a variety of important cell functions, including assembling cells into various tissues and organs, regulating growth and cell-cell communication. Developing a tailored in vitro cell culture environment that mimics the intricate and organized nanoscale meshwork of native ECM is desirable. Recent studies have shown the potential of hydrogels to mimic native ECM. Such an engineered native-like ECM is more likely to provide cells with rational cues for diagnostic and therapeutic studies. The research for novel biomaterials has led to an extension of the scope and techniques used to fabricate biomimetic hydrogel scaffolds for tissue engineering and regenerative medicine applications. In this article, we detail the progress of the current state-of-the-art engineering methods to create cell-encapsulating hydrogel tissue constructs as well as their applications in in vitro models in biomedicine.

  19. Novel thermosensitive chitosan hydrogels: in vivo evaluation.

    Science.gov (United States)

    Patois, Emilie; Osorio-da Cruz, Suzanne; Tille, Jean-Christophe; Walpoth, Beat; Gurny, Robert; Jordan, Olivier

    2009-11-01

    Chitosan is an attractive biopolymer for the preparation of hydrogels. Its unique combination of biocompatibility, biodegradability, bioadhesivity, and tissue-promoting abilities allows pharmaceutical applications. We investigated novel thermosensitive hydrogels based on chitosan homogeneously reacetylated to a deacetylation degree of about 50%, combined with selected polyols or polyoses such as trehalose, a nontoxic polysaccharide. The latter, a gel-inducing and lyoprotective agent enabled the formulation to be lyophilized and rehydrated without affecting the thermosensitive behavior. This made possible long-term storage and promoted its use in a clinical setup. The thermally induced sol-gel transition allowed injectability and in situ setting. Rheological characterization revealed that storage moduli could be increased by one decade by increasing the chitosan concentration from 1.4 to 2.2% (w/w). Evaluation in vivo provided evidence of in situ implant formation in subcutaneous tissue of Sprague-Dawley rats and permanence for up to 3 months. Histopathological analysis demonstrated a mild, chronic, inflammatory reaction that disappeared with the complete absorption of the gel implant over a few months period. Such in situ forming hydrogels could be advantageous for specific applications in drug delivery and tissue engineering.

  20. 21 CFR 878.4022 - Hydrogel wound dressing and burn dressing.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hydrogel wound dressing and burn dressing. 878... Hydrogel wound dressing and burn dressing. (a) Identification. A hydrogel wound dressing is a sterile or... percent) and capable of absorbing exudate. This classification does not include a hydrogel wound...

  1. An Investigation into the Behavior of Disc Blake Wear

    Directory of Open Access Journals (Sweden)

    Muneer A. H.Jassim

    2007-01-01

    Full Text Available A real method of predication brake pad wear ,could lead to substantiol economies of time and money. This paper describes how such a procedure has been used and gives the results to establish is reliability by comparing the predicted wear with that which actually occurs in an existing service. The experimental work was carried out on three different commercial samples ,tested under different operation conditions (speed,load,time...etcusing a test ring especially modified for this purpose. Abrasive wear is mainly studied , since it is the type of wear that takes place in such arrangements. Samples wear tested in presences of sand or mud between the mating surfaces under different operational conditions of speed, load and braking time .Mechanical properties of the pad material samples (hardness, young,s modulus and collapse load under pure bending condition wear established . The thermal conductivity and surface roughness of the pad material wear also found in order to enable comparison between the surface condition before and after testing. Sliding velocity had a small effect on the wear rate but it had great effect on friction coefficient. Wear rate was affected mainly by the surface temperature which causing a reduction friction coefficient and increasing the wear rate. Surface roughness had almost no effect on the wear rate since it was proved experimentally ,that the surface becomes softer during operation .mechanical properties of the pad material had fluctuating effect on wear rate. The existence of solid particles between pad and disc increasing wear rate and friction coefficient while the mud caused a reduction in wear rate of the pad surface since it acts as a lubricant absorbing the surface heat generated during sliding the area of contact between pad and disc. wear rate obtained experimentally agreed fairly well that found from empirically obtained equations.

  2. Is tooth wear in the primary dentition predictive of tooth wear in the permanent dentition? Report from a longitudinal study.

    LENUS (Irish Health Repository)

    Harding, M A

    2010-03-01

    To determine the prevalence of tooth wear in the permanent dentition of a sample of 12-year-old school children and establish whether an association exists between tooth wear recorded now and tooth wear recorded in their primary dentition at age five.

  3. Characterization of the wear response of a modified zinc-based alloy vis-à-vis a conventional zinc-based alloy and a bearing bronze at a high sliding speed

    Science.gov (United States)

    Prasad, B. K.; Yegneswaran, A. H.; Patwardhan, A. K.

    1996-11-01

    In this investigation, an attempt has been made to examine the wear response of a modified zinc-based alloy at a high speed (4.60 m/s) of sliding over a range of applied pressures. A conventional zinc-based alloy and a bearing bronze have also been subjected to identical tests with a view to assess the working capability of the modified alloy with respect to the existing ones. The wear characteristics of the alloys have been correlated with their microstructural features, while operating wear mechanisms have been studied through analyses of wear surfaces, subsurfaces, and debris particles. The conventional zinc-based alloy attained most inferior wear behavior when compared with that of the modified (zinc-based) alloy and the bronze. Interestingly, the modified alloy exhibited its wear response to be much better than that of the conventional zinc-based alloy due to the presence of nickel/silicon containing (hard and thermally stable) microconstituents. Moreover, the modified alloy also seized at a pressure similar to that of the bronze, although its wear rate prior to seizure was more than that of the latter. The study clearly indicates that it is possible to develop modified versions of zinc-based alloys having much improved wear characteristics over the conventional variety; the information gains special attention in view of the high speed of sliding selected in this study.

  4. Processing Techniques and Applications of Silk Hydrogels in Bioengineering

    Directory of Open Access Journals (Sweden)

    Michael Floren

    2016-09-01

    Full Text Available Hydrogels are an attractive class of tunable material platforms that, combined with their structural and functional likeness to biological environments, have a diversity of applications in bioengineering. Several polymers, natural and synthetic, can be used, the material selection being based on the required functional characteristics of the prepared hydrogels. Silk fibroin (SF is an attractive natural polymer for its excellent processability, biocompatibility, controlled degradation, mechanical properties and tunable formats and a good candidate for the fabrication of hydrogels. Tremendous effort has been made to control the structural and functional characteristic of silk hydrogels, integrating novel biological features with advanced processing techniques, to develop the next generation of functional SF hydrogels. Here, we review the several processing methods developed to prepare advanced SF hydrogel formats, emphasizing a bottom-up approach beginning with critical structural characteristics of silk proteins and their behavior under specific gelation environments. Additionally, the preparation of SF hydrogel blends and other advanced formats will also be discussed. We conclude with a brief description of the attractive utility of SF hydrogels in relevant bioengineering applications.

  5. Hydrogel microspheres from biodegradable polymers as drug delivery systems

    Science.gov (United States)

    A series of hydrogel microspheres were prepared from pectin, a hydrophilic biopolymer, and zein, a hydrophobic biopolymer, at varying weight ratios. The hydrogel formulation was conducted in the presence of calcium or other divalent metal ions at room temperature under mild conditions. Studies of ...

  6. A Photochromic Copolymer Hydrogel Contact Lens: From Synthesis to Application

    Directory of Open Access Journals (Sweden)

    Xiaoli Yang

    2016-01-01

    Full Text Available A photochromic poly(2-hydroxyl-ethyl methacrylate-N-vinylpyrrolidone-spironaphthoxazine hydrogel (p(HEMA-NVP-SPO has been designed and synthesized by free radical polymerization in this work. The chemical and structural information of hydrogels was investigated by IR spectra, equilibrium water content (EWC, and SEM. The IR spectra confirmed successful synthesis of copolymer. The domain of NVP contributed to not only EWC but also inner structure of hydrogel, while SPO had little influence on these properties of hydrogel. The photochromic behaviors of hydrogel including photochromic properties and thermal fading kinetics were systematically studied and compared with hydrogel made by immersing method. Results showed that when SPO was incorporated in hydrogel by polymerization, maximum absorbance wavelength got shorter, and the relaxation half-life became longer. In addition, salicylic acid as a drug model could be loaded into hydrogel by immersing method, and its sustained drug release in a given period was dependent on the characteristics of solution and loading time.

  7. Extracellular matrix hydrogels from decellularized tissues: Structure and function.

    Science.gov (United States)

    Saldin, Lindsey T; Cramer, Madeline C; Velankar, Sachin S; White, Lisa J; Badylak, Stephen F

    2017-02-01

    Extracellular matrix (ECM) bioscaffolds prepared from decellularized tissues have been used to facilitate constructive and functional tissue remodeling in a variety of clinical applications. The discovery that these ECM materials could be solubilized and subsequently manipulated to form hydrogels expanded their potential in vitro and in vivo utility; i.e. as culture substrates comparable to collagen or Matrigel, and as injectable materials that fill irregularly-shaped defects. The mechanisms by which ECM hydrogels direct cell behavior and influence remodeling outcomes are only partially understood, but likely include structural and biological signals retained from the native source tissue. The present review describes the utility, formation, and physical and biological characterization of ECM hydrogels. Two examples of clinical application are presented to demonstrate in vivo utility of ECM hydrogels in different organ systems. Finally, new research directions and clinical translation of ECM hydrogels are discussed. More than 70 papers have been published on extracellular matrix (ECM) hydrogels created from source tissue in almost every organ system. The present manuscript represents a review of ECM hydrogels and attempts to identify structure-function relationships that influence the tissue remodeling outcomes and gaps in the understanding thereof. There is a Phase 1 clinical trial now in progress for an ECM hydrogel. Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  8. Functionalized graphene hydrogel-based high-performance supercapacitors.

    Science.gov (United States)

    Xu, Yuxi; Lin, Zhaoyang; Huang, Xiaoqing; Wang, Yang; Huang, Yu; Duan, Xiangfeng

    2013-10-25

    Functionalized graphene hydrogels are prepared by a one-step low-temperature reduction process and exhibit ultrahigh specific capacitances and excellent cycling stability in the aqueous electrolyte. Flexible solid-state supercapacitors based on functionalized graphene hydrogels are demonstrated with superior capacitive performances and extraordinary mechanical flexibility.

  9. Versatile click alginate hydrogels crosslinked via tetrazine-norbornene chemistry.

    Science.gov (United States)

    Desai, Rajiv M; Koshy, Sandeep T; Hilderbrand, Scott A; Mooney, David J; Joshi, Neel S

    2015-05-01

    Alginate hydrogels are well-characterized, biologically inert materials that are used in many biomedical applications for the delivery of drugs, proteins, and cells. Unfortunately, canonical covalently crosslinked alginate hydrogels are formed using chemical strategies that can be biologically harmful due to their lack of chemoselectivity. In this work we introduce tetrazine and norbornene groups to alginate polymer chains and subsequently form covalently crosslinked click alginate hydrogels capable of encapsulating cells without damaging them. The rapid, bioorthogonal, and specific click reaction is irreversible and allows for easy incorporation of cells with high post-encapsulation viability. The swelling and mechanical properties of the click alginate hydrogel can be tuned via the total polymer concentration and the stoichiometric ratio of the complementary click functional groups. The click alginate hydrogel can be modified after gelation to display cell adhesion peptides for 2D cell culture using thiol-ene chemistry. Furthermore, click alginate hydrogels are minimally inflammatory, maintain structural integrity over several months, and reject cell infiltration when injected subcutaneously in mice. Click alginate hydrogels combine the numerous benefits of alginate hydrogels with powerful bioorthogonal click chemistry for use in tissue engineering applications involving the stable encapsulation or delivery of cells or bioactive molecules.

  10. Preparation and assessment of ketamine hydrogels for prolonged ...

    African Journals Online (AJOL)

    produced 62.82 % analgesia), the effect of the test formulations seem good for probable therapeutic use. ... The other chemicals ... Table 1: Composition of ketamine hydrogel ... The hydrogels were assessed for colour, ... hair and other fatty and connective tissues) with .... was administered to humans at a dose range of.

  11. Difference between Chitosan Hydrogels via Alkaline and Acidic Solvent Systems

    Science.gov (United States)

    Nie, Jingyi; Wang, Zhengke; Hu, Qiaoling

    2016-10-01

    Chitosan (CS) has generated considerable interest for its desirable properties and wide applications. Hydrogel has been proven to be a major and vital form in the applications of CS materials. Among various types of CS hydrogels, physical cross-linked CS hydrogels are popular, because they avoided the potential toxicity and sacrifice of intrinsic properties caused by cross-linking or reinforcements. Alkaline solvent system and acidic solvent system are two important solvent systems for the preparation of physical cross-linked CS hydrogels, and also lay the foundations of CS hydrogel-based materials in many aspects. As members of physical cross-linked CS hydrogels, gel material via alkaline solvent system showed significant differences from that via acidic solvent system, but the reasons behind are still unexplored. In the present work, we studied the difference between CS hydrogel via alkaline system and acidic system, in terms of gelation process, hydrogel structure and mechanical property. In-situ/pseudo in-situ studies were carried out, including fluorescent imaging of gelation process, which provided dynamic visualization. Finally, the reasons behind the differences were explained, accompanied by the discussion about design strategy based on gelation behavior of the two systems.

  12. Reinforcement of hydrogels using three-dimensionally printed microfibres

    NARCIS (Netherlands)

    Visser, Jetze; Melchels, Ferry P. W.; Jeon, June E.; van Bussel, Erik M.; Kimpton, Laura S.; Byrne, Helen M.; Dhert, Wouter J. A.; Dalton, Paul D.; Hutmacher, Dietmar W.; Malda, J

    2015-01-01

    Despite intensive research, hydrogels currently available for tissue repair in the musculoskeletal system are unable to meet the mechanical, as well as the biological, requirements for successful outcomes. Here we reinforce soft hydrogels with highly organized, high-porosity microfibre networks that

  13. Biocompatible cellulose-based superabsorbent hydrogels with antimicrobial activity.

    Science.gov (United States)

    Peng, Na; Wang, Yanfeng; Ye, Qifa; Liang, Lei; An, Yuxing; Li, Qiwei; Chang, Chunyu

    2016-02-10

    Current superabsorbent hydrogels commercially applied in the disposable diapers have disadvantages such as weak mechanical strength, poor biocompatibility, and lack of antimicrobial activity, which may induce skin allergy of body. To overcome these hassles, we have developed novel cellulose based hydrogels via simple chemical cross-linking of quaternized cellulose (QC) and native cellulose in NaOH/urea aqueous solution. The prepared hydrogel showed superabsorbent property, high mechanical strength, good biocompatibility, and excellent antimicrobial efficacy against Saccharomyces cerevisiae. The presence of QC in the hydrogel networks not only improved their swelling ratio via electrostatic repulsion of quaternary ammonium groups, but also endowed their antimicrobial activity by attraction of sections of anionic microbial membrane into internal pores of poly cationic hydrogel leading to the disruption of microbial membrane. Moreover, the swelling properties, mechanical strength, and antibacterial activity of hydrogels strongly depended on the contents of quaternary ammonium groups in hydrogel networks. The obtained data encouraged the use of these hydrogels for hygienic application such as disposable diapers.

  14. Lab-on-a-chip devices with patterned hydrogels

    NARCIS (Netherlands)

    Gümüscü, B.

    2016-01-01

    Hydrogels are considered to be in the class of smart materials that find application in diagnostic, therapeutic,and fundamental science tools for miniaturized total analysis systems. In this thesis, the focus is on three major applications of patterned hydrogels, which are explored as an alternative

  15. Synthesis and Swelling Properties of Thermosensitive Hydrogels based on Terpolymerization

    Institute of Scientific and Technical Information of China (English)

    Cai Hua NI; Xian Yu ZENG; He HUANG

    2005-01-01

    Novel thermosensitive hydrogels based on polymerization of N-isopropyl acrylamide,Sodium acrylate, and diacetone acrylamide were synthesized. The swelling ratio and dynamic swelling were investigated. The results indicated that the hydrogels exhibited high water uptake and themosensitivity. The swelling properties and volume phase transition temperature could be adjusted by contents of the comonomers in the gels.

  16. Keratin sponge/hydrogel II, active agent delivery

    Science.gov (United States)

    Keratin sponge/hydrogels from oxidation and reduction hydrolysis of fine and coarse wool fibers were formed to behave as cationic hydrogels to swell and release active agents in the specific region of the gastro-intestinal (GI) tract. Their porous, interpenetrating networks (IPN) were effective for...

  17. Synthesis and Characterization of Phosphated Konjac Glucomannan Hydrogels

    Institute of Scientific and Technical Information of China (English)

    Li Gui CHEN; Zhi Lan LIU; Ying Jun CHEN; Ren Xi ZHUO

    2005-01-01

    Konjac glucomannan (KGM) was crosslinked with sodium tripolyphosphate (STPP) to synthesize hydrogels. The crosslinking reaction was confirmed by FT-IR. The results of degradation test show that the hydrogels retain the enzymatic degradation character of KGM and can be degraded for 74.45% in 5 days by cellulase E0240.

  18. Injectable hyaluronic acid hydrogel for 19F magnetic resonance imaging

    NARCIS (Netherlands)

    Yang, X.; Sun, Y.; Kootala, S.; Hilborn, J.; Heerschap, A.; Ossipov, D.

    2014-01-01

    We report on a 19F labeled injectable hyaluronic acid (HA) hydrogel that can be monitored by both 1H and 19F MR imaging. The HA based hydrogel formed via carbazone reaction can be obtained within a minute by simple mixing of HA-carbazate and HA-aldehyde derivatized polymers. 19F contrast agent was l

  19. Application of hydrogels in heart valve tissue engineering.

    Science.gov (United States)

    Zhang, Xing; Xu, Bin; Puperi, Daniel S; Wu, Yan; West, Jennifer L; Grande-Allen, K Jane

    2015-01-01

    With an increasing number of patients requiring valve replacements, there is heightened interest in advancing heart valve tissue engineering (HVTE) to provide solutions to the many limitations of current surgical treatments. A variety of materials have been developed as scaffolds for HVTE including natural polymers, synthetic polymers, and decellularized valvular matrices. Among them, biocompatible hydrogels are generating growing interest. Natural hydrogels, such as collagen and fibrin, generally show good bioactivity but poor mechanical durability. Synthetic hydrogels, on the other hand, have tunable mechanical properties; however, appropriate cell-matrix interactions are difficult to obtain. Moreover, hydrogels can be used as cell carriers when the cellular component is seeded into the polymer meshes or decellularized valve scaffolds. In this review, we discuss current research strategies for HVTE with an emphasis on hydrogel applications. The physicochemical properties and fabrication methods of these hydrogels, as well as their mechanical properties and bioactivities are described. Performance of some hydrogels including in vitro evaluation using bioreactors and in vivo tests in different animal models are also discussed. For future HVTE, it will be compelling to examine how hydrogels can be constructed from composite materials to replicate mechanical properties and mimic biological functions of the native heart valve.

  20. Self-assembly of polypyrrole/chitosan composite hydrogels.

    Science.gov (United States)

    Huang, Hao; Wu, Jiao; Lin, Xi; Li, Liang; Shang, Songmin; Yuen, Marcus Chun-wah; Yan, Guoping

    2013-06-05

    Hydrogels based on the polypyrrole (PPy)/chitosan (CS) composite are self-assembled and characterized for their electrical and swelling properties. The static polymerization of pyrrole monomer in aqueous solution containing CS is accompanied with the formation of PPy/CS composite hydrogel. The feed order in the reaction process plays a key role in the formation of the hydrogels. The participation of one-dimensional PPy blocks in the formation of the hydrogel network avoids a possible migration of PPy from the hydrogel. The effect of pH and ionic strength on the physical properties of PPy/CS composite hydrogels are investigated in detail. The results indicate that the pH-sensitive PPy/CS composite hydrogels show good water absorbencies in distilled water and saline solution. This method may open a new opportunity for the fabrication of composite hydrogels associating the biomacromolecules and conducting polymers, and the improvement of the comprehensive performance of the resulting products. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Hydrogel coated monoliths for enzymatic hydrolysis of penicillin G

    NARCIS (Netherlands)

    De Lathouder, K.M.; Smeltink, M.W.; Straathof, A.J.J.; Paasman, M.A.; Van de Sandt, E.J.A.X.; Kapteijn, F.; Moulijn, J.A.

    2008-01-01

    The objective of this work was to develop a hydrogel-coated monolith for the entrapment of penicillin G acylase (E. coli, PGA). After screening of different hydrogels, chitosan was chosen as the carrier material for the preparation of monolithic biocatalysts. This protocol leads to active immobilize

  2. Processing Techniques and Applications of Silk Hydrogels in Bioengineering

    Science.gov (United States)

    Floren, Michael; Migliaresi, Claudio; Motta, Antonella

    2016-01-01

    Hydrogels are an attractive class of tunable material platforms that, combined with their structural and functional likeness to biological environments, have a diversity of applications in bioengineering. Several polymers, natural and synthetic, can be used, the material selection being based on the required functional characteristics of the prepared hydrogels. Silk fibroin (SF) is an attractive natural polymer for its excellent processability, biocompatibility, controlled degradation, mechanical properties and tunable formats and a good candidate for the fabrication of hydrogels. Tremendous effort has been made to control the structural and functional characteristic of silk hydrogels, integrating novel biological features with advanced processing techniques, to develop the next generation of functional SF hydrogels. Here, we review the several processing methods developed to prepare advanced SF hydrogel formats, emphasizing a bottom-up approach beginning with critical structural characteristics of silk proteins and their behavior under specific gelation environments. Additionally, the preparation of SF hydrogel blends and other advanced formats will also be discussed. We conclude with a brief description of the attractive utility of SF hydrogels in relevant bioengineering applications. PMID:27649251

  3. A constitutive model of nanocomposite hydrogels with nanoparticle crosslinkers

    Science.gov (United States)

    Wang, Qiming; Gao, Zheming

    2016-09-01

    Nanocomposite hydrogels with only nanoparticle crosslinkers exhibit extraordinarily higher stretchability and toughness than the conventional organically crosslinked hydrogels, thus showing great potential in the applications of artificial muscles and cartilages. Despite their potential, the microscopic mechanics details underlying their mechanical performance have remained largely elusive. Here, we develop a constitutive model of the nanoparticle hydrogels to elucidate the microscopic mechanics behaviors, including the microarchitecture and evolution of the nanoparticle crosslinked polymer chains during the mechanical deformation. The constitutive model enables us to understand the Mullins effect of the nanocomposite hydrogels, and the effects of nanoparticle concentrations and sizes on their cyclic stress-strain behaviors. The theory is quantitatively validated by the tensile tests on a nanocomposite hydrogel with nanosilica crosslinkers. The theory can also be extended to explain the mechanical behaviors of existing hydrogels with nanoclay crosslinkers, and the necking instability of the composite hydrogels with both nanoparticle crosslinkers and organic crosslinkers. We expect that this constitutive model can be further exploited to reveal mechanics behaviors of novel particle-polymer chain interactions, and to design unprecedented hydrogels with both high stretchability and toughness.

  4. Macromolecular diffusion in self-assembling biodegradable thermosensitive hydrogels

    NARCIS (Netherlands)

    Vermonden, T.; Jena, S.S.; Barriet, D.; Censi, R.; Gucht, van der J.; Hennink, W.E.; Siegel, R.A.

    2010-01-01

    Hydrogel formation triggered by a change in temperature is an attractive mechanism for in situ gelling biomaterials for pharmaceutical applications such as the delivery of therapeutic proteins. In this study, hydrogels were prepared from ABA triblock polymers having thermosensitive poly(N-(2-hydroxy

  5. HIGH-STRENGTH POLY(METH)ACRYLAMIDE COPOLYMER HYDROGELS

    NARCIS (Netherlands)

    WIERSMA, JA; SOS, M; PENNINGS, AJ

    1994-01-01

    The hydrogels described here are copolymers of acrylamide and methacrylamide highly cross-linked with piperazine diacrylamide or 4,7,10-trioxa-1,13-tridecanediamine diacrylamide by radical polymerisation in highly concentrated aqueous and aqueous gelatin solutions. The hydrogels were characterised b

  6. Syntheses of PVA/starch blend hydrogels by irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Zhai, Maolin [Peking Univ., College of Chemistry, Inst. of Applied Chemistry, Beijing (China); Yoshii, Fumio; Kume, Tamikazu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment; Hashim, Kamaruddin [Malaysian Institute for Nuclear Technology Research, Bangi (Malaysia)

    2002-03-01

    A series of excellent PVA/starch blend hydrogels were prepared by gamma and electric beam (EB) radiation at room temperature. The influence of dose, the content of starch in blend system on the properties of the prepared hydrogels were investigated. The gel strength was improved obviously after adding starch into PVA hydrogels, but the swelling properties decreased slightly due to low swelling capacity of starch. The effect of component of starch on the properties of PVA/starch blend hydrogels as well as the reaction mechanism between PVA and starch under irradiation were investigated further. Comparing with PVA/starch blend hydrogels, PVA/amylose blend hydrogels had higher gel fraction, mechanical strength, and lower swelling capacity. PVA/amylopectin blend hydrogels were over the left. It indicated that the amylose of starch was a key component that influenced the properties of PVA/starch blend hydrogels. The analyses of FTIR and DSC spectra of the prepared gel samples after extracting sol indicated that there was a grafting reaction between PVA and starch molecules except for the crosslinking of PVA molecules under irradiation, and the amylose of starch was a key reactive component. (author)

  7. Wear Studies on Metal Matrix Composites: a Taguchi Approach

    Institute of Scientific and Technical Information of China (English)

    S. Basavarajappa; G. Chandramohan

    2005-01-01

    An attempt has been made to study the influence of wear parameters like applied load, sliding speed, sliding distance and percentage of reinforcement on the dry sliding wear of the metal matrix composites. A plan of experiments,based on techniques of Taguchi, was pedormed to acquire data in controlled way. An orthogonal array and the analysis of variance were employed to investigate the influence of process parameters on the wear of composites. The objective is to establish a correlation between dry sliding wear of composites and wear parameters. These correlations were obtained by multiple regressions. Finally, confirmation tests were conducted to verify the experimental results foreseen from the mentioned correlations.

  8. Structural study and preliminary biological evaluation on the collagen hydrogel crosslinked by γ-irradiation.

    Science.gov (United States)

    Zhang, Xiangmei; Xu, Ling; Huang, Xin; Wei, Shicheng; Zhai, Maolin

    2012-11-01

    Under γ-irradiation, concentrated collagen solutions yielded collagen hydrogels and liquid products. The molecular structure of collagen hydrogels and the source of the liquid products were studied. Furthermore, preliminary biological properties of the hydrogels were investigated. The results revealed that crosslinking occurred to form collagen hydrogel and the crosslinking density increased with the increasing of the absorbed dose, and the collagen hydrogels showed enhanced mechanical properties. Meanwhile, collagen underwent radiation degradation and water was squeezed out from hydrogel by contraction of hydrogel, yielding liquid products. Collagen hydrogels induced by γ-irradiation maintained the backbone structure of collagen, and tyrosine partially involved in crosslinking. The irradiated collagen hydrogels have higher denatured temperature, can promote fibroblasts proliferation, and their degradation rate in vivo depended on the absorbed dose. The comprehensive results suggested that the collagen hydrogels prepared by radiation crosslinking preserved the triple helical conformation, possessed improved thermal stability and mechanical properties, excellent biocompatibility, which is expected to favor its application as biomaterials.

  9. Computational Study of pH-sensitive Hydrogel-based Microfluidic Flow Controllers

    Directory of Open Access Journals (Sweden)

    Jundika C. Kurnia

    2011-08-01

    Full Text Available This computational study investigates the sensing and actuating behavior of a pH-sensitive hydrogel-based microfluidic flow controller. This hydrogel-based flow controller has inherent advantage in its unique stimuli-sensitive properties, removing the need for an external power supply. The predicted swelling behavior the hydrogel is validated with steady-state and transient experiments. We then demonstrate how the model is implemented to study the sensing and actuating behavior of hydrogels for different microfluidic flow channel/hydrogel configurations: e.g., for flow in a T-junction with single and multiple hydrogels. In short, the results suggest that the response of the hydrogel-based flow controller is slow. Therefore, two strategies to improve the response rate of the hydrogels are proposed and demonstrated. Finally, we highlight that the model can be extended to include other stimuli-responsive hydrogels such as thermo-, electric-, and glucose-sensitive hydrogels.

  10. Fabrication of Negative Charged Poly (Ethylene glycol)-diacrylate Hydrogel as a Bone Tissue Engineering scaffold

    Institute of Scientific and Technical Information of China (English)

    WANG Ya-qi; LIU Jie; TAN Fei; XIE Wei

    2016-01-01

    Objective To improve the cell attachment of PEGDA hydrogel, the SMAS small molecule was used to modify the PEGDA hydrogel. The charged hydrogel would show improved cell attachment and enhanced protein adsorption caused by enhancement of electrostatic adsorption.Method In this study, a series of charged hydrogels were produced by adding different concentrations of charged small molecule monomer into the PEGDA solution. Then, we investigate the physicochemical and biological characteristics of charged hydrogels, including FTIR, swelling ratio, contact angle, cell attachment.Result The results indicate that the charged monomer had been successfully incorporated into PEGDA hydrogel. Meanwhile, the protein adsorption of the hydrogel increased with increasing concentration of charge modification. Moreover, compared to PEGDA hydrogel, the cell attachment significantly improved on the charged hydrogel.Conclusion The charged hydrogel would be a promising scaffold candidate for bone tissue engineering.

  11. Kinetics of Iododeoxyuridine release from sodium alginate hydrogel in vitro

    Institute of Scientific and Technical Information of China (English)

    XU Yong-hua; Mandar R Jagtap; ZHANG Dian-bo; YING Jun; Ronald C McGarry; Marc S. Mendonca; Gordon McLennan

    2006-01-01

    Objective To investigate the kinetics of Iododeoxyuridine (IUdR)release from sodium alginate hydrogel cross-linked with varying amounts of calcium chloride, and to optimize sustained release for further periadventitial I125-labeled IUdR delivery to suppress intimal hyperplasia following angioplasty in vivo.Methods Four hydrogels,composed of 0.16 mEq sodium alginate and 200 g IUdR, were cross-linked with calcium chloride to yield ion equivalence (IE) ratios (Calcium: alginate) of 3:1, 4:1, 5:1, or 6:1. 2 ml of normal saline was placed on top of each hydrogel and allowed to remain in contact at 37℃ for up to 30 days. At set time intervals, the concentration and amount of IUdR in the eluate were assayed by high performance liquid chromatography using UV detection and Water symmetry C18 column. The data for accumulated release rate and concentration in the eluate were calculated based on the calibration curve of peak area versus IUdR concentration. The hydrogel morphologic degradations were also observed. Results The hydrogels entrapped 92.9%, 98.6%, 98.4% and 98.6% of the IUdR with 3:1, 4:1, 5:1 and 6:1 IE ratios, respectively. IUdR concentration in eluates from 3:1 IE ratio hydrogel decreased faster than that from other hydrogels over time (P < 0.01). The 4:1, 5:1 and 6:1 IE ratio hydrogels produced more than 10 μm IUdR concentrations in eluates for the first 8 days, while the 3:1 IE ratio hydrogel for 4 days. IUdR release rates of the 4:1, 5:1 and 6:1 IE ratio hydrogels were very close, however they were lower than that of the 3:1 IE hydrogel in the first 48 hours (P < 0.05). At day 30, the 3:1 and 4:1 IE ratio hydrogels had 100% and 88% degradation, but no significant degradation was observed in the other hydrogels. Conclusion The sodium alginate hydrogel with 4:1 IE ratio exhibited an optimal IUdR sustained release and almost complete degradation in 30 days. (J Intervent Radiol,2006 , 15: 293-298)

  12. Engineered Polymeric Hydrogels for 3D Tissue Models

    Directory of Open Access Journals (Sweden)

    Sujin Park

    2016-01-01

    Full Text Available Polymeric biomaterials are widely used in a wide range of biomedical applications due to their unique properties, such as biocompatibility, multi-tunability and easy fabrication. Specifically, polymeric hydrogel materials are extensively utilized as therapeutic implants and therapeutic vehicles for tissue regeneration and drug delivery systems. Recently, hydrogels have been developed as artificial cellular microenvironments because of the structural and physiological similarity to native extracellular matrices. With recent advances in hydrogel materials, many researchers are creating three-dimensional tissue models using engineered hydrogels and various cell sources, which is a promising platform for tissue regeneration, drug discovery, alternatives to animal models and the study of basic cell biology. In this review, we discuss how polymeric hydrogels are used to create engineered tissue constructs. Specifically, we focus on emerging technologies to generate advanced tissue models that precisely recapitulate complex native tissues in vivo.

  13. Removal of toxic metal ions with magnetic hydrogels.

    Science.gov (United States)

    Ozay, Ozgur; Ekici, Sema; Baran, Yakup; Aktas, Nahit; Sahiner, Nurettin

    2009-09-01

    Hydrogels, based on 2-acrylamido-2-methyl-1-propansulfonic acid (AMPS) were synthesized via photopolymerization technique and used for the preparation of magnetic responsive composite hydrogels. These composite hydrogels with magnetic properties were further utilized for the removal of toxic metal ions such as Cd(II), Co(II), Fe(II), Pb(II), Ni(II), Cu(II) and Cr(III) from aqueous environments. It was revealed that hydrogel networks with magnetic properties can effectively be utilized in the removal of pollutants. The results verified that magnetic iron particle containing p(AMPS) hydrogel networks provide advantageous over conventional techniques. Langmuir and Freundlich adsorption isotherms were applied for toxic metal removal and both isotherms were fit reasonably well for the metal ion absorptions.

  14. Engineering three-dimensional cell mechanical microenvironment with hydrogels.

    Science.gov (United States)

    Huang, Guoyou; Wang, Lin; Wang, Shuqi; Han, Yulong; Wu, Jinhui; Zhang, Qiancheng; Xu, Feng; Lu, Tian Jian

    2012-12-01

    Cell mechanical microenvironment (CMM) significantly affects cell behaviors such as spreading, migration, proliferation and differentiation. However, most studies on cell response to mechanical stimulation are based on two-dimensional (2D) planar substrates, which cannot mimic native three-dimensional (3D) CMM. Accumulating evidence has shown that there is a significant difference in cell behavior in 2D and 3D microenvironments. Among the materials used for engineering 3D CMM, hydrogels have gained increasing attention due to their tunable properties (e.g. chemical and mechanical properties). In this paper, we provide an overview of recent advances in engineering hydrogel-based 3D CMM. Effects of mechanical cues (e.g. hydrogel stiffness and externally induced stress/strain in hydrogels) on cell behaviors are described. A variety of approaches to load mechanical stimuli in 3D hydrogel-based constructs are also discussed.

  15. Advances in the Fabrication of Antimicrobial Hydrogels for Biomedical Applications

    Directory of Open Access Journals (Sweden)

    Carmen M. González-Henríquez

    2017-02-01

    Full Text Available This review describes, in an organized manner, the recent developments in the elaboration of hydrogels that possess antimicrobial activity. The fabrication of antibacterial hydrogels for biomedical applications that permits cell adhesion and proliferation still remains as an interesting challenge, in particular for tissue engineering applications. In this context, a large number of studies has been carried out in the design of hydrogels that serve as support for antimicrobial agents (nanoparticles, antibiotics, etc.. Another interesting approach is to use polymers with inherent antimicrobial activity provided by functional groups contained in their structures, such as quaternary ammonium salt or hydrogels fabricated from antimicrobial peptides (AMPs or natural polymers, such as chitosan. A summary of the different alternatives employed for this purpose is described in this review, considering their advantages and disadvantages. Finally, more recent methodologies that lead to more sophisticated hydrogels that are able to react to external stimuli are equally depicted in this review.

  16. States of Water in Hydrogels Containing with Glyceryl Methacrylate

    Institute of Scientific and Technical Information of China (English)

    LI Qin-hua; LIU Li; HUANG Zhi-rong; LIN Dong-qing

    2014-01-01

    Hydrogel materials were prepared by thermopolymerization with different content of glyceryl methacrylate and hydroxyethyl methacrylate. The different states of water in swelling hydrogels were described and studied by differential scanning calorimetry (DSC). It was found that the hydrophilicity of GMA was stronger than HEMA, the water content and bound water of GMA hydrogel are higher than HEMA hydrogel. With the increase of GMA content, the content of free water in hydrogel increased. When GMA content was lower than 50%, the increase of GMA content also increased the content of bound water; but when GMA content was higher than 50%, the increase of GMA content decreased the content of bound water, which was caused by the chain hydrogen bond formed on the GMA chain with hydroxyl group each other.

  17. Synthesis and characterization of hydrogel bonded with rare earth

    Institute of Scientific and Technical Information of China (English)

    YAN Changhao; JIAO Lianlian; GUO Chunfang; ZHANG Ming; QIU Guanming

    2008-01-01

    Chitosan-poly(acrylic acid) hydrogel bonded with Eu3+ was prepared by radical solution polymerization. Biodegradable chitosan,N,N'-methylen-diacrylamide, and potassium persulphate were used as the basic material, cross-linking agent, and initiator, respectively. The structure and thermal property of hydrogel were characterized by infrared spectrometry, X-ray diffraction, scanning electron microscopy, and differential scanning calorimetry. The swollen property and fluorescent performance were also characterized. The results showed that the rare earth presented unique distribution in the hydrogel due to the formation of chemical bonds after polymerization. The glass transition tem-perature of the hydrogel decreased remarkably, which might broaden the range of its elastic application considerably. Moreover, the charac-teristic fluorescent emission of Eu3+ was observed in the hydrogel, which was indicative of the excellent luminescent performance.

  18. Radiation-chemical preparation of poly(vinyl alcohol) hydrogels

    Science.gov (United States)

    Duflot, Anastasia V.; Kitaeva, Natalia K.; Duflot, Vladimir R.

    2015-02-01

    This work reports the usage of method of radiation-chemical synthesis to prepare cross-linked hydrogels from poly(vinyl alcohol) modified with glycidyl methacrylate. Synthesis kinetics of modified poly(vinyl alcohol) and properties of hydrogels were studied. The gel fraction, swelling, mechanical properties, and water content of the hydrogels were measured. It was found that gel fraction increases with increasing radiation dose, concentration of modified poly(vinyl alcohol), and reaches 60%. It was established by differential scanning calorimetry that a fraction of the "bound" water in hydrogels is 50-70% and independent of gel fraction content. In addition to "bound" and "free" states, water in hydrogels is also present in the intermediate state.

  19. Thermoresponsive hydrogels in biomedical applications: A seven-year update.

    Science.gov (United States)

    Klouda, Leda

    2015-11-01

    Thermally responsive hydrogels modulate their gelation behavior upon temperature change. Aqueous solutions solidify into hydrogels when a critical temperature is reached. In biomedical applications, the change from ambient temperature to physiological temperature can be employed. Their potential as in situ forming biomaterials has rendered these hydrogels very attractive. Advances in drug delivery, tissue engineering and cell sheet engineering have been made in recent years with the use of thermoresponsive hydrogels. The scope of this article is to review the literature on thermosensitive hydrogels published over the past seven years. The article concentrates on natural polymers as well as synthetic polymers, including systems based on N-isopropylacrylamide (NIPAAm), poly(ethylene oxide)-b-poly(propylene oxide)-b-poly(ethylene oxide) (PEO-PPO-PEO), poly(ethylene glycol) (PEG)-biodegradable polyester copolymers, poly(organophosphazenes) and 2-(dimethylamino) ethyl methacrylate (DMAEMA).

  20. Classification, processing and application of hydrogels: A review.

    Science.gov (United States)

    Ullah, Faheem; Othman, Muhammad Bisyrul Hafi; Javed, Fatima; Ahmad, Zulkifli; Md Akil, Hazizan

    2015-12-01

    This article aims to review the literature concerning the choice of selectivity for hydrogels based on classification, application and processing. Super porous hydrogels (SPHs) and superabsorbent polymers (SAPs) represent an innovative category of recent generation highlighted as an ideal mould system for the study of solution-dependent phenomena. Hydrogels, also termed as smart and/or hungry networks, are currently subject of considerable scientific research due to their potential in hi-tech applications in the biomedical, pharmaceutical, biotechnology, bioseparation, biosensor, agriculture, oil recovery and cosmetics fields. Smart hydrogels display a significant physiochemical change in response to small changes in the surroundings. However, such changes are reversible; therefore, the hydrogels are capable of returning to its initial state after a reaction as soon as the trigger is removed.

  1. Development of sago starch hydrogel for wound dressing

    Energy Technology Data Exchange (ETDEWEB)

    Kamaruddin Hashim; Khairul Zaman HJ. Mohd Dahlan; Kamarudin Bahari [Malaysian Institute for Nuclear Technology Research (MINT), Bangi (Malaysia); Yoshii, Fumio; Kume, Tamikazu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    2001-03-01

    Sago starch is utilized in Malaysia mainly for food production. The purpose of the research is to diversify the use of sago starch for medical application particularly in development of hydrogel burn wound dressing. The sago starch is blending with mixture of PVP and PVA to improve the degree of crosslink, mechanical properties, swelling ability and tackiness of the blend hydrogel (sago/PVA and sago PVP). Additives have been introduced into the system such as, polypropylene glycol or carboxymethyl cellulose to improved further the swelling ability and tackiness properties of the blend hydrogel as well as other properties. Effect of irradiation dose on the blend hydrogel has also been studied to optimize the effective dose for blend hydrogel and simultaneously for sterilization purpose. (author)

  2. Mechanics and chemical thermodynamics of a temperature-sensitive hydrogel

    Science.gov (United States)

    Cai, Shengqiang; Suo, Zhigang

    2011-03-01

    A temperature-sensitive hydrogel is a network of polymers containing monomers, whose interaction with water molecules can be tuned dramatically by changing temperature. In most cases, the swelling ratio of a temperature-sensitive hydrogel changes discontinuously upon heating above or cooling below a critical temperature, which is called volume phase transition. Interestingly, the coexistence of swollen phases and shrunk phases are frequently observed in the experiments for temperature-sensitive hydrogels and additionally, people have also discovered that a uniaxial force can induce phase transition in a temperature-sensitive gel bar .In order to understand these phenomena, we studied the mechanics and chemical thermodynamics of a temperature-sensitive hydrogel bar, by using the free-energy landscape of a bar made from PNIPAM gel. Following Gibbs, we plot the phase diagram of a temperature-sensitive hydrogel bar under uniaxial force. This work is supported by the NSF (CMMI-0800161) and by the MRSEC at Harvard University.

  3. Preparation and characterization of bioglass/polyvinyl alcohol composite hydrogel

    Energy Technology Data Exchange (ETDEWEB)

    Xu Hong [College of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 (China); Wang Yingjun [College of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 (China); Zheng Yudong [College of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Chen Xiaofeng [College of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 (China); Ren Li [College of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 (China); Wu Gang [College of Materials Science and Engineering, South China University of Technology, Guangzhou 510641 (China); Huang Xiaoshan [College of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China)

    2007-06-01

    In order to form firm active fixation with the adjacent bone, a new kind of bioactive composite hydrogel was prepared with polyvinyl alcohol (PVA) and bioglass (BG) through ultrasonic dispersion, heat-high-pressure and freeze/thawed technique. A digital speckle correlation method (DSCM) was utilized to characterize the mechanical properties of the series of BG/PVA composites. Results showed that at different load pressures, the composite hydrogel displayed different displacement and deformation in the V field. Results also showed that an increase of PVA percentage (15-30 wt%) or of bioglass percentage (2-10 wt%) in composite hydrogel could lead to an increase in the elastic compression modulus. Scanning electron microscope results indicated that bioglass was uniformly dispersed in the BG/PVA composite hydrogel. The BG/PVA composite hydrogel shows a promising prospect as a new bionic cartilage implantation material.

  4. E-beam-patterned hydrogels to control nanoscale surface bioactivity

    Science.gov (United States)

    Krsko, P.; Saaem, I.; Clancy, R.; Geller, H.; Soteropoulos, P.; Libera, M.

    2005-11-01

    We are interested in controlling the spatial distribution of proteins on surfaces at cellular and subcellular length scales. To do this, we use a variation of e-beam lithography in a field-emission scanning electron microscope (SEM) to radiation crosslink thin films of water- soluble polymers such as poly(ethylene glycol) [PEG] and poly (carboxylic acids). We can simultaneously pattern the resulting hydrogels on silicon or glass surfaces with nanoscale and microscale feature sizes. Using hydroxy-terminated PEG 6800 we create gels with swell ratios between unity and fifteen depending on the degree of radiation crosslinking, and the swelling properties can be interpreted in terms of the Flory-Rehner formulation modified for one-dimensional swelling. While lightly-crosslinked PEG gels resist protein adsorption and cell adhesion as expected, highly crosslinked PEG gels adsorb such proteins as fibronectin and laminin and consequently become adhesive to fibroblasts, macrophages, and neurons. By spatially modulating the degree of crosslinking, we can localize these cells on surfaces and, for example, direct neurite outgrowth. If instead of using hydroxy-terminated PEG we use amine- terminated PEG, we introduce the additional flexibility of creating high-swelling PEG gels that resist nonspecific protein adsorption but to which specific proteins can be covalently bound. These can be surface patterned at submicron spacings, and we can pattern 7500 nanohydrogels in a 100 micron diameter arrays in 10 seconds. This is an areal density ~104 times greater than a modern DNA/protein chip, and the required bioreagents for chip fabrication and processing are proportionately less. We can bind fibronectin and laminin to different arrays, and we show that these proteins maintain their biospecificity after binding to the nanohydrogels with high fidelity. Looking to applications in next-generation protein-chip technology, our most recent experiments compare the performance of nanohydrogel

  5. Contact Thermal Analysis and Wear Simulation of a Brake Block

    Directory of Open Access Journals (Sweden)

    Nándor Békési

    2013-01-01

    Full Text Available The present paper describes an experimental test and a coupled contact-thermal-wear analysis of a railway wheel/brake block system through the braking process. During the test, the friction, the generated heat, and the wear were evaluated. It was found that the contact between the brake block and the wheel occurs in relatively small and slowly moving hot spots, caused by the wear and the thermal effects. A coupled simulation method was developed including numerical frictional contact, transient thermal and incremental wear calculations. In the 3D simulation, the effects of the friction, the thermal expansion, the wear, and the temperature-dependent material properties were also considered. A good agreement was found between the results of the test and the calculations, both for the thermal and wear results. The proposed method is suitable for modelling the slowly oscillating wear caused by the thermal expansions in the contact area.

  6. 7-Be Implantation in Plastics for Prosthesis Wear Studies

    Science.gov (United States)

    Greife, Uwe; Erikson, L.; Patel, N.; Wimmer, M.; Dwiwedi, Y.; Laurent, M.; Chipps, K.; Blackmon, J.; Kozub, R.; Bardayan, D.; Gross, C.; Stracener, D.; Smith, M.; Nesaraya, C.; Rehm, E.; Ahmed, I.; Greene, J.

    2010-11-01

    The current generation of highly cross linked ultrahigh molecular weight polyethylenes (PE) for hip and knee joint replacement have achieved such low in vitro wear rates that efforts have been underway to develop more sensitive methods to measure polyethylene wear. The most widely used technique, the gravimetric method, suffers from the notable disadvantage that mass gain by fluid absorption can considerably exceed mass loss by wear, making the wear measurement inaccurate, sometimes even leading to negative ``wear'' values. The purpose of this experiment was to investigate the use of a radioactive tracer, beryllium-7 (7-Be), to circumvent the problem of fluid absorption and thereby achieve a much more sensitive and accurate wear measurement. This proof of principle study demonstrated the general feasibility of 7-Be implantation (performed at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory) for PE wear analysis.

  7. Dynamic SEM wear studies of tungsten carbide cermets

    Science.gov (United States)

    Brainard, W. A.; Buckley, D. H.

    1975-01-01

    Dynamic friction and wear experiments were conducted in a scanning electron microscope. The wear behavior of pure tungsten carbide and composite with 6 and 15 weight percent cobalt binder was examined. Etching of the binder was done to selectively determine the role of the binder in the wear process. Dynamic experiments were conducted as the WC and bonded WC cermet surfaces were transversed by a 50 micron radiused diamond stylus. These studies show that the predominant wear process in WC is fracture initiated by plastic deformation. The wear of the etched cermets is similar to pure WC. The presence of the cobalt binder reduces both friction and wear. The cementing action of the cobalt reduces granular separation and promotes a dense polished layer because of its low shear strength film-forming properties. The wear debris generated from unetched surface is approximately the same composition as the bulk.

  8. Wear aspects of internal combustion engine valves

    Science.gov (United States)

    Panţuru, M.; Chicet, D.; Paulin, C.; Alexandru, A.; Munteanu, C.

    2016-08-01

    Because the surface engineering is becoming an increasingly viable alternative to the constructive changes made to improve the efficiency of internal combustion engines, have been proposed and tested various types of coatings of some organs of internal combustion engines. One vital organ is the engine valves, which is subjected during operation to combined thermal, mechanical, corrosion and wear solicitations, which are leading to severe corrosion and complete breakdown. In this paper were analyzed aspects of valves wear and the active surfaces were coated using the atmospheric plasma spraying method (APS) with two commercial powders: Ni-Al and YSZ. Microstructural analyzes were made on these layers and also observations regarding the possibility of using them as thermal barrier and anti-oxidant coatings.

  9. Exposure and risks from wearing asbestos mitts

    Directory of Open Access Journals (Sweden)

    Tindall Matthew

    2005-10-01

    Full Text Available Abstract Background Very high fibre inhalation exposure has been measured while people were wearing personal protective equipment manufactured from chrysotile asbestos. However, there is little data that relates specifically to wearing asbestos gloves or mitts, particularly when used in hot environments such as those found in glass manufacturing. The aim of this study was to assess the likely personal exposure to asbestos fibres when asbestos mitts were used. Results Three types of work activity were simulated in a small test room with unused mitts and artificially aged mitts. Neither pair of mitts were treated to suppress the dust emission. The measured respirable fibre exposure levels ranged from Conclusion People who wore asbestos mitts were likely to have been exposed to relatively low levels of airborne chrysotile asbestos fibres, certainly much lower than the standards that were accepted in the 1960's and 70's. The cancer risks from this type of use are likely to be very low.

  10. Low-Wear Ball-Bearing Separator

    Science.gov (United States)

    Hawkinson, Elden L.

    1991-01-01

    Proposed ball-bearing separator for use in cryogenic pump stronger and more resistant to wear. Consists of molded plastic-and-metal composite ring imbued with solid lubricant and containing embedded metal ring. Obtains combination of strength and lubricity. Before molding and machining, ring includes tooling portion for handling and indexing. Molded composite blend of PTFE and fluorinated ethylene/propylene (FEP) filled with brass and bronze powder and molybdenum disulfide powder.

  11. Wear debris in cemented total hip arthroplasty.

    Science.gov (United States)

    Huo, M H; Salvati, E A; Buly, R L

    1991-03-01

    One of the most prevalent clinical problems in long-term follow up of total hip arthroplasty patients is loosening of prosthetic fixation. Factors contributing to mechanical failure of total hip reconstruction are complex and multiple. It has become increasingly apparent that wear debris from the prosthetic components may contribute significantly to this process. The authors summarize some of the current concepts concerning the detrimental effects of metallic debris in total hip arthroplasty.

  12. Wear Resistant Rubber Tank Track Pads

    Science.gov (United States)

    1975-10-01

    stereospecific SBR (Stereon 750), SBR/polybutadiene blends (Fhilprene 1609/Cis-4 1350 (or Cis-4 1351), Ameripoi 1834/Ameripol CB 1352) and alfin ...polybutadiene blends has confirmed this improvement in tread wear. The uncertainty regarding the future commercial availibility of the alfin catalyzed...polybutadiene blend) (S212-2), and HYTRANS 1227-2S9-1 ( alfin catalyzed copolymer of butadiene/ styrene) (S223-4) to determine their effect on the resistance to

  13. A Predictive Multiscale Model of Wear

    Science.gov (United States)

    2011-03-09

    of Robust Protective Coatings for Metal Components Subjected to Extreme Conditions,” at the Computer Aided Molecular Design Conference, St. Johns...2006 to July 31, 2010 on developing and applying first principles quantum mechanics methods to describe mechanical wear of chrome -plated steel gun...than the corresponding value for Fe3+, which makes sense since Fe’s orbitals are more contracted than Cr’s due to Fe’s larger effective nuclear charge

  14. Hydrogel design of experiments methodology to optimize hydrogel for iPSC-NPC culture.

    Science.gov (United States)

    Lam, Jonathan; Carmichael, S Thomas; Lowry, William E; Segura, Tatiana

    2015-03-11

    Bioactive signals can be incorporated in hydrogels to direct encapsulated cell behavior. Design of experiments methodology methodically varies the signals systematically to determine the individual and combinatorial effects of each factor on cell activity. Using this approach enables the optimization of three ligands concentrations (RGD, YIGSR, IKVAV) for the survival and differentiation of neural progenitor cells.

  15. Wear measurement by surface layer activation

    Energy Technology Data Exchange (ETDEWEB)

    Blatchley, C.

    1987-05-01

    The purpose of these projects was to demonstrate the capability for precisely but remotely measuring small increments of wear, erosion or corrosion in utility components using detectors mounted outside the system to monitor the presence of radionuclide surface markers. These gamma ray emitting markers are produced by surface layer activation (SLA) using a high energy particle beam from a Van de Graaff or cyclotron particle accelerator. The work was divided into three major projects: (1) determination of the feasibility of applying SLA based surface monitoring techniques to key power plant systems; (2) a field demonstration of SLA monitoring in steam turbine components subject to severe solid particle erosion; and (3) a field demonstration of SLA wear or corrosion monitoring of components in boiler auxiliaries. In the field tests, surface material removal was successfully measured from both selected systems, demonstrating the feasibility of the technique for long term diagnostic condition monitoring. Three bearing components in a boiler circulation pump were monitored almost continuously for a period of over 5 months until the pump was stopped due to electrical problems unrelated to the wear measurements. Solid particle erosion from two stop valve bypass valves was measured during a series of nine startup cycles. Both test demonstrations confirmed the earlier feasibility estimates and showed how SLA markers can be used to provide valuable diagnostic information to plant operators. 22 refs., 63 figs., 29 tabs.

  16. Study of Wear of Pitched Blade Impellers

    Directory of Open Access Journals (Sweden)

    I. Fořt

    2000-01-01

    Full Text Available A study was made of the erosion of blades of pitched blade impellers in a suspension of solid particles in a liquid under a turbulent regime of flow of an agitated charge. The wear of the impeller is described by an analytical approximation in exponential form, and the influence of the pitch angle on the impeller blade wear was studied experimentally. It follows from the results of the experiments made that the wear rate of the pitched blade impellers increases linearly with the decreasing pitch angle within the interval a Î á15°; 45° ń. The proposed form of radial profile of the leading edge of the impeller blade enables us to calculate the surface of the worn blade. This quantity significantly decreases with the length of the period when the blades are affected by the solid particles, and its values calculated according to the suggested profile of the worn blade fit fairly well with the experimentally determined values. The results of the experiments performed are valid for homogeneous distribution of solid particles in an agitated suspension.

  17. Corrosion and wear in plasma electrosurgical devices

    Science.gov (United States)

    Gaspredes, J.; Ryan, T. P.; Stalder, K. R.; Woloszko, J.

    2017-02-01

    Data were previously reported on studies of the effects of electrical discharges on the corrosion and wear of simple, single-wire test devices immersed in isotonic saline 1 . This work showed that there are a wide variety of mechanisms that can explain various aspects of electrode mass loss, even with very simple electrode geometries and operating conditions. It was found that the electrode material composition played an important role. Subsequently, our studies were expanded to include more realistic device geometries and operating conditions. This paper shows the results of studies on wear characteristics of electrodes made from a variety of highly corrosion resistant metals and alloys, including Waspaloy, Hastelloy, Inconel, Havar, Monel, and other pure metals such as Hafnium. All of these metals underwent wear testing under clinically relevant conditions. Depending on the operating conditions, multiple discrete physical and chemical effects were observed at different locations on the surface of an individual millimeter-scale device electrode. Scanning electron microscope (SEM) micrographs, Energy-dispersive X-ray spectroscopy (EDS) and area loss data will be presented for a variety of test conditions and electrode materials.

  18. Doping Silicon Wafers with Boron by Use of Silicon Paste

    Institute of Scientific and Technical Information of China (English)

    Yu Gao; Shu Zhou; Yunfan Zhang; Chen Dong; Xiaodong Pi; Deren Yang

    2013-01-01

    In this work we introduce recently developed silicon-paste-enabled p-type doping for silicon.Boron-doped silicon nanoparticles are synthesized by a plasma approach.They are then dispersed in solvents to form silicon paste.Silicon paste is screen-printed at the surface of silicon wafers.By annealing,boron atoms in silicon paste diffuse into silicon wafers.Chemical analysis is employed to obtain the concentrations of boron in silicon nanoparticles.The successful doping of silicon wafers with boron is evidenced by secondary ion mass spectroscopy (SIMS) and sheet resistance measurements.

  19. Silicon: electrochemistry and luminescence

    NARCIS (Netherlands)

    Kooij, Ernst Stefan

    1997-01-01

    The electrochemistry of crystalline and porous silicon and the luminescence from porous silicon has been studied. One chapter deals with a model for the anodic dissolution of silicon in HF solution. In following chapters both the electrochemistry and various ways of generating visible luminescenc

  20. Silicon: electrochemistry and luminescence

    NARCIS (Netherlands)

    Kooij, Ernst Stefan

    1997-01-01

    The electrochemistry of crystalline and porous silicon and the luminescence from porous silicon has been studied. One chapter deals with a model for the anodic dissolution of silicon in HF solution. In following chapters both the electrochemistry and various ways of generating visible