WorldWideScience

Sample records for wavelength conversion factor

  1. Wavelength conversion devices

    DEFF Research Database (Denmark)

    Mikkelsen, Benny; Durhuus, Terji; Jørgensen, Carsten

    1996-01-01

    system requirements. The ideal wavelength converter should be transparent to the bit rate and signal format and provide an unchirped output signal with both a high extinction ratio and a large signal-to-noise ratio. It should allow conversion to both shorter and longer wavelengths with equal performance...

  2. Wavelength conversion technology

    DEFF Research Database (Denmark)

    Stubkjær, Kristian

    1998-01-01

    Optical wavelength conversion is currently attracting much interest. This is because it enables full flexibility and eases management of WDM fibre networks. The tutorial will review existing and potential application areas. Examples of node architectures and network demonstrators that use wavelen...

  3. Wavelength conversion techniques and devices

    DEFF Research Database (Denmark)

    Danielsen, Søren Lykke; Mikkelsen, Benny; Hansen, Peter Bukhave

    1997-01-01

    Taking into account the requirements to the converters e.g., bit rate transparency (at least up to 10 Gbit/s), polarisation independence, wavelength independence, moderate input power levels, high signal-to-noise ratio and high extinction ratio interferometric wavelength convertors are very...... interesting for use in WDM optical fibre networks. However, the perfect converter has probably not yet been fabricated and new techniques such as conversion relying on cross-absorption modulation in electro-absorption modulators might also be considered in pursue of effective conversion devices...

  4. New preemptive scheduling for OBS networks considering cascaded wavelength conversion

    Science.gov (United States)

    Gao, Xingbo; Bassiouni, Mostafa A.; Li, Guifang

    2009-05-01

    In this paper we introduce a new preemptive scheduling technique for next generation optical burst-switched networks considering the impact of cascaded wavelength conversions. It has been shown that when optical bursts are transmitted all optically from source to destination, each wavelength conversion performed along the lightpath may cause certain signal-to-noise deterioration. If the distortion of the signal quality becomes significant enough, the receiver would not be able to recover the original data. Accordingly, subject to this practical impediment, we improve a recently proposed fair channel scheduling algorithm to deal with the fairness problem and aim at burst loss reduction simultaneously in optical burst switching. In our scheme, the dynamic priority associated with each burst is based on a constraint threshold and the number of already conducted wavelength conversions among other factors for this burst. When contention occurs, a new arriving superior burst may preempt another scheduled one according to their priorities. Extensive simulation results have shown that the proposed scheme further improves fairness and achieves burst loss reduction as well.

  5. Wavelength Conversion of DP-QPSK Signals in a Silicon Polarization Diversity Circuit

    DEFF Research Database (Denmark)

    Vukovic, Dragana; Schroeder, Jochen; Ding, Yunhong

    2015-01-01

    Multichannel wavelength conversion is experimentally demonstrated for high-speed 128 Gb/s dual-polarization quadrature phase-shift keying signals using four-wave mixing in a polarization diversity circuit with silicon nanowires as nonlinear elements. The wavelength conversion performance is inves...... is investigated for both single-and three-channel input signals, showing quality factors well >9.8 dB (corresponding to bit-error-ratios better than 10(-3)) and with a negligible power penalty compared with the back-to-back case....

  6. Technologies for all-optical wavelength conversion in DWDM networks

    DEFF Research Database (Denmark)

    Wolfson, David; Fjelde, Tina; Kloch, Allan

    2001-01-01

    Different techniques for all-optical wavelength conversion are reviewed and the advantages and disadvantages seen from a system perspective are highlighted. All-optical wavelength conversion will play a major role in making cost-effective network nodes in future high-speed WDM networks, where...

  7. Span Restoration in Optical Networks with Limited Wavelength Conversion

    DEFF Research Database (Denmark)

    Ruepp, Sarah Renée; Buron, Jakob Due; Andriolli, N

    2007-01-01

    Next generation optical networks provide functionalities to dynamically provision and recover connections, while emerging technologies allow for the conversion between wavelengths. These devices are however expensive and hence it is likely that only few are deployed throughout the network...... converter-saving wavelength assignment in GMPLS networks. The converter saving property of the Suggested Vector is particularly desirable in span restoration, where the pre-failure path stubs have to be merged to the restoration path at the failure-adjacent nodes. In order to avoid wavelength conversion....... Furthermore, we describe different scenarios to extend the suggested vector wavelength assignment scheme to multi-domain networks with focus on span restoration....

  8. All-optical multi-wavelength conversion with negative power penalty by a commercial SOA-MZI for WDM wavelength multicast

    NARCIS (Netherlands)

    Yan, N.; Jung, H.D.; Tafur Monroy, I.; Waardt, de H.; Koonen, A.M.J.

    2007-01-01

    WDM wavelength multicast is demonstrated by all-optical multi-wavelength conversion at 10 Gb/s using a commercial SOA-MZI. We report for the first time simultaneous one-to-four conversion with negative power penalty of 1.84 dB.

  9. All-optical wavelength conversion and signal regeneration using an electroabsorption modulator

    DEFF Research Database (Denmark)

    Højfeldt, Sune; Bischoff, Svend; Mørk, Jesper

    2000-01-01

    All-optical wavelength conversion and signal regeneration based on cross-absorption modulation in an InGaAsP quantum well electroabsorption modulator (EAM) is studied at different bit rates. We present theoretical results showing wavelength conversion efficiency in agreement with existing...

  10. All-optical wavelength conversion and signal regeneration using an electroabsorption modulator

    DEFF Research Database (Denmark)

    Højfeldt, Sune; Bischoff, Svend; Mørk, Jesper

    1999-01-01

    All-optical wavelength conversion in an InGaAsP quantum well electroabsorption modulator is studied at different bit-rates. We present theoretical results showing wavelength conversion efficiency in agreement with existing experimental results, and signal regeneration capability is demonstrated....

  11. Polarization insensitive wavelength conversion in a dispersion-engineered silicon waveguide

    DEFF Research Database (Denmark)

    Pu, Minhao; Hu, Hao; Peucheret, Christophe

    2012-01-01

    We experimentally demonstrate polarization-insensitive all optical wavelength conversion of a 10-Gb/s DPSK data signal based on four-wave mixing in a silicon waveguide with an angled-pump scheme. Dispersion engineering is applied to the silicon waveguide to obtain similar four-wave mixing convers...... conversion performances for both the TE and TM modes. Bit-error rate measurements are performed and error-free operation is achieved. We also demonstrate polarization-insensitive wavelength conversion with a large separation between the idler and signal using a dual-pump configuration....

  12. 160 Gb/s Raman-assisted notch-filtered XPM wavelength conversion and transmission

    DEFF Research Database (Denmark)

    Galili, Michael; Oxenløwe, Leif Katsuo; Mulvad, Hans Christian Hansen

    2007-01-01

    In-line wavelength conversion of 160 Gb/s data by Raman-assisted notch-filtered XPM is demonstrated for 130 km total transmission. The improvement in system performance from applying Raman gain during conversion is shown.......In-line wavelength conversion of 160 Gb/s data by Raman-assisted notch-filtered XPM is demonstrated for 130 km total transmission. The improvement in system performance from applying Raman gain during conversion is shown....

  13. Broadband wavelength conversion in hydrogenated amorphous silicon waveguide with silicon nitride layer

    Science.gov (United States)

    Wang, Jiang; Li, Yongfang; Wang, Zhaolu; Han, Jing; Huang, Nan; Liu, Hongjun

    2018-01-01

    Broadband wavelength conversion based on degenerate four-wave mixing is theoretically investigated in a hydrogenated amorphous silicon (a-Si:H) waveguide with silicon nitride inter-cladding layer (a-Si:HN). We have found that enhancement of the non-linear effect of a-Si:H waveguide nitride intermediate layer facilitates broadband wavelength conversion. Conversion bandwidth of 490 nm and conversion efficiency of 11.4 dB were achieved in a numerical simulation of a 4 mm-long a-Si:HN waveguide under 1.55 μm continuous wave pumping. This broadband continuous-wave wavelength converter has potential applications in photonic networks, a type of readily manufactured low-cost highly integrated optical circuits.

  14. Effective preemptive scheduling scheme for optical burst-switched networks with cascaded wavelength conversion consideration

    Science.gov (United States)

    Gao, Xingbo

    2010-03-01

    We introduce a new preemptive scheduling technique for next-generation optical burst switching (OBS) networks considering the impact of cascaded wavelength conversions. It has been shown that when optical bursts are transmitted all optically from source to destination, each wavelength conversion performed along the lightpath may cause certain signal-to-noise deterioration. If the distortion of the signal quality becomes significant enough, the receiver would not be able to recover the original data. Accordingly, subject to this practical impediment, we improve a recently proposed fair channel scheduling algorithm to deal with the fairness problem and aim at burst loss reduction simultaneously in OBS environments. In our scheme, the dynamic priority associated with each burst is based on a constraint threshold and the number of already conducted wavelength conversions among other factors for this burst. When contention occurs, a new arriving superior burst may preempt another scheduled one according to their priorities. Extensive simulation results have shown that the proposed scheme further improves fairness and achieves burst loss reduction as well.

  15. Mechanism of wavelength conversion in polystyrene doped with benzoxanthene: emergence of a complex.

    Science.gov (United States)

    Nakamura, Hidehito; Shirakawa, Yoshiyuki; Kitamura, Hisashi; Sato, Nobuhiro; Shinji, Osamu; Saito, Katashi; Takahashi, Sentaro

    2013-01-01

    Fluorescent guest molecules doped in polymers have been used to convert ultraviolet light into visible light for applications ranging from optical fibres to filters for the cultivation of plants. The wavelength conversion process involves the absorption of light at short wavelengths followed by fluorescence emission at a longer wavelength. However, a precise understanding of the light conversion remains unclear. Here we show light responses for a purified polystyrene base substrates doped with fluorescent benzoxanthene in concentrations varied over four orders of magnitude. The shape of the excitation spectrum for fluorescence emission changes significantly with the concentration of the benzoxanthene, indicating formation of a base substrate/fluorescent molecule complex. Furthermore, the wavelength conversion light yield increases in three stages depending on the nature of the complex. These findings identify a mechanism that will have many applications in wavelength conversion materials.

  16. Optical wavelength conversion by cross-phase modulation of data signals up to 640 Gb/s

    DEFF Research Database (Denmark)

    Galili, Michael; Oxenløwe, Leif Katsuo; Mulvad, Hans Christian Hansen

    2008-01-01

    In this paper, all-optical wavelength conversion by cross-phase modulation in a highly nonlinear fiber is investigated. Regenerative properties of the wavelength converter are demonstrated, and the effect of adding Raman gain to enhance the performance of the wavelength converter is shown. The wa....... The wavelength conversion scheme is demonstrated at the record-high bit rate of 640 Gb/s.......In this paper, all-optical wavelength conversion by cross-phase modulation in a highly nonlinear fiber is investigated. Regenerative properties of the wavelength converter are demonstrated, and the effect of adding Raman gain to enhance the performance of the wavelength converter is shown...

  17. Ultra-high-speed wavelength conversion in a silicon photonic chip

    DEFF Research Database (Denmark)

    Hu, Hao; Ji, Hua; Galili, Michael

    2011-01-01

    We have successfully demonstrated all-optical wavelength conversion of a 640-Gbit/s line-rate return-to-zero differential phase-shift keying (RZ-DPSK) signal based on low-power four wave mixing (FWM) in a silicon photonic chip with a switching energy of only ~110 fJ/bit. The waveguide dispersion...... of the silicon nanowire is nano-engineered to optimize phase matching for FWM and the switching power used for the signal processing is low enough to reduce nonlinear absorption from twophoton- absorption (TPA). These results demonstrate that high-speed wavelength conversion is achievable in silicon chips...

  18. Highly coherent red-shifted dispersive wave generation around 1.3 μm for efficient wavelength conversion

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xia; Bi, Wanjun [Key Laboratory of Materials for High Power Laser, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); University of Chinese Academy of Sciences, Beijing 100039 (China); Chen, Wei; Xue, Tianfeng; Hu, Lili; Liao, Meisong, E-mail: liaomeisong@siom.ac.cn [Key Laboratory of Materials for High Power Laser, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800 (China); Gao, Weiqing [School of Electronic Science and Applied Physics, Hefei University of Technology, Hefei 230009 (China)

    2015-03-14

    This research investigates the mechanism of the optical dispersive wave (DW) and proposes a scheme that can realize an efficient wavelength conversion. In an elaborately designed photonic crystal fiber, a readily available ytterbium laser operating at ∼1 μm can be transferred to the valuable 1.3 μm wavelength range. A low-order soliton is produced to concentrate the energy of the DW into the target wavelength range and improve the degree of coherence. The input chirp is demonstrated to be a factor that enhances the wavelength conversion efficiency. With a positive initial chirp, 76.6% of the pump energy in the fiber can be transferred into a spectral range between 1.24 and 1.4 μm. With the use of a grating compressor, it is possible to compress the generated coherent DW of several picoseconds into less than 90 fs.

  19. Construction of a single/multiple wavelength RZ optical pulse source at 40 GHz by use of wavelength conversion in a high-nonlinearity DSF-NOLM

    DEFF Research Database (Denmark)

    Yu, Jianjun; Yujun, Qian; Jeppesen, Palle

    2001-01-01

    A single or multiple wavelength RZ optical pulse source at 40 GHz is successfully obtained by using wavelength conversion in a nonlinear optical loop mirror consisting of high nonlinearity-dispersion shifted fiber.......A single or multiple wavelength RZ optical pulse source at 40 GHz is successfully obtained by using wavelength conversion in a nonlinear optical loop mirror consisting of high nonlinearity-dispersion shifted fiber....

  20. Widely tunable wavelength conversion with extinction ratio enhancement using PCF-based NOLM

    DEFF Research Database (Denmark)

    Kwok, C.H.; Lee, S.H.; Chow, K.K.

    2005-01-01

    A widely tunable wavelength conversion scheme has been demonstrated using a 64-m-long dispersion-flattened high-nonlinearity photonic crystal fiber in a nonlinear optical loop mirror. Wavelength conversion range of over 60 nm with a 10-Gb/s return-to-zero signal was obtained with the output...... extinction ratio (ER) maintained above 13 dB. The proposed scheme can also improve the output ER and remove the bit-error-rate floor if a degraded signal is used....

  1. Comparison of wavelength conversion efficiency between silicon waveguide and microring resonator

    DEFF Research Database (Denmark)

    Xiong, Meng; Ding, Yunhong; Ou, Haiyan

    2016-01-01

    Wavelength conversion based on degenerate four-wave mixing (FWM) was demonstrated and compared between silicon nanowire and microring resonator (MRR). 15 dB enhancement of conversion efficiency (CE) with relatively low input pump power (5 mW) was achieved experimentally in an MRR. The impacts...

  2. Polarization Insensitive Wavelength Conversion Based on Four-Wave Mixing in a Silicon Nanowire

    DEFF Research Database (Denmark)

    Pu, Minhao; Hu, Hao; Peucheret, Christophe

    2012-01-01

    We experimentally demonstrate, for the first time, polarization-insensitive wavelength conversion of a 10 Gb/s NRZ-OOK data signal based on four-wave mixing in a silicon nanowire with bit-error rate measurements.......We experimentally demonstrate, for the first time, polarization-insensitive wavelength conversion of a 10 Gb/s NRZ-OOK data signal based on four-wave mixing in a silicon nanowire with bit-error rate measurements....

  3. Solutions for ultra-high speed optical wavelength conversion and clock recovery

    DEFF Research Database (Denmark)

    Oxenløwe, Leif Katsuo; Galili, Michael; Mulvad, Hans Christian Hansen

    2006-01-01

    This paper reports on our recent advances in ultra-fast optical communications relying on ultra-short pulses densely stacked in ultra-high bit rate serial data signals at a single wavelength. The paper describes details in solutions for the network functionalities of wavelength conversion and clock...... recovery at bit rates up to 320 Gb/s...

  4. Wavelength conversion by use of four-wave mixing in a novel optical loop configuration

    DEFF Research Database (Denmark)

    Yu, Jianjun; Jeppesen, Palle

    2000-01-01

    and the signal waves. By use of the novel loop configuration, nonreturn-to-zero wavelength conversion at 10 Gbits/s is achieved. The FWM-to-pump ratio, the FWM-to-signal ratio, and the signal-to-noise ratio are improved by 17.9, 18.8, and 8.2 dB, respectively. A principle experiment of wavelength conversion...

  5. Characterization and modeling of microstructured chalcogenide fibers for efficient mid-infrared wavelength conversion.

    Science.gov (United States)

    Xing, Sida; Grassani, Davide; Kharitonov, Svyatoslav; Billat, Adrien; Brès, Camille-Sophie

    2016-05-02

    We experimentally demonstrate wavelength conversion in the 2 µm region by four-wave mixing in an AsSe and a GeAsSe chalcogenide photonic crystal fibers. A maximum conversion efficiency of -25.4 dB is measured for 112 mW of coupled continuous wave pump in a 27 cm long fiber. We estimate the dispersion parameters and the nonlinear refractive indexes of the chalcogenide PCFs, establishing a good agreement with the values expected from simulations. The different fiber geometries and glass compositions are compared in terms of performance, showing that GeAsSe is a more suited candidate for nonlinear optics at 2 µm. Building from the fitted parameters we then propose a new tapered GeAsSe PCF geometry to tailor the waveguide dispersion and lower the zero dispersion wavelength (ZDW) closer to the 2 µm pump wavelength. Numerical simulations shows that the new design allows both an increased conversion efficiency and bandwidth, and the generation of idler waves further in the mid-IR regions, by tuning the pump wavelength in the vicinity of the fiber ZDW.

  6. All-Optical Wavelength Conversion by Picosecond Burst Absorption in Colloidal PbS Quantum Dots.

    Science.gov (United States)

    Geiregat, Pieter; Houtepen, Arjan J; Van Thourhout, Dries; Hens, Zeger

    2016-01-26

    All-optical approaches to change the wavelength of a data signal are considered more energy- and cost-effective than current wavelength conversion schemes that rely on back and forth switching between the electrical and optical domains. However, the lack of cost-effective materials with sufficiently adequate optoelectronic properties hampers the development of this so-called all-optical wavelength conversion. Here, we show that the interplay between intraband and band gap absorption in colloidal quantum dots leads to a very strong and ultrafast modulation of the light absorption after photoexcitation in which slow components linked to exciton recombination are eliminated. This approach enables all-optical wavelength conversion at rates matching state-of-the-art convertors in speed, yet with cost-effective solution-processable materials. Moreover, the stronger light-matter interaction allows for implementation in small-footprint devices with low switching energies. Being a generic property, the demonstrated effect opens a pathway toward low-power integrated photonics based on colloidal quantum dots as the enabling material.

  7. Low Noise Quantum Frequency Conversion from Rb Wavelengths to Telecom O-band

    Science.gov (United States)

    Li, Xiao; Solmeyer, Neal; Stack, Daniel; Quraishi, Qudsia

    2015-05-01

    Ideal quantum repeaters would be composed of long-lived quantum memories entangled with flying qubits. They are becoming essential elements to achieve quantum communication over long distances in a quantum network. However, quantum memories based on neutral atoms operate at wavelengths in the near infrared, unsuitable for long distance communication. The ability to coherently convert photons entangled with quantum memories into telecom wavelengths reduces the transmission loss in optical fibers and therefore dramatically improves the range of a quantum repeater. Furthermore, quantum frequency conversion (QFC) can enable entanglement and communication between different types of quantum memories, thus creating a versatile hybrid quantum network. A recent experiment has shown the conversion of heralded photons from Rb-based memories to the telecom C-band. We implement a setup using a nonlinear PPLN waveguide for the QFC into a wavelength region where the noise-floor would be limited by dark counts rather than pump photons. Our approach uses a pump laser at a much longer wavelength. It has the advantage that the strong pump itself and the broad background in the PPLN can be nearly completely filtered from the converted signal. Such low background level allows for the conversion to be done on the heralding photon, which enables the generated entanglement to be used in a scalable way to multiple nodes remotely situated and to subsequent protocols.

  8. Polarization-insensitive all-optical wavelength conversion of 320 Gb/s RZ-DQPSK signals using a Ti:PPLN waveguide

    DEFF Research Database (Denmark)

    Hu, Hao; Nouroozi, R.; Ludwig, R.

    2010-01-01

    Polarization-insensitive wavelength conversion of a single channel 320 Gb/s RZ-DQPSK data signal using a Ti:PPLN waveguide in a bi-directional loop configuration with less than 0.5 dB polarization sensitivity is reported. The conversion efficiency with polarization scrambling of the signal was -2...... little broadening and chirping, indicating the potential for wavelength conversion of even much higher data rates.......Polarization-insensitive wavelength conversion of a single channel 320 Gb/s RZ-DQPSK data signal using a Ti:PPLN waveguide in a bi-directional loop configuration with less than 0.5 dB polarization sensitivity is reported. The conversion efficiency with polarization scrambling of the signal was -21...

  9. Wavelength conversion from C- to L-band at 10 Gbit/s including transmission over 80 km of SSMF

    DEFF Research Database (Denmark)

    Poulsen, Henrik Nørskov; Buxens Azcoaga, Alvaro Juan; Clausen, Anders

    2000-01-01

    As the need for capacity increases, means to accommodate the growth is getting increasingly important. Hence, higher bit rates and an ever increasing number of WDM channels is being employed. This has led to the introduction of the L-band (ranging from 1570 to 1610 nm) as the new transmission...... window, opening up for-in conjunction with the C-band-an astonishing 80 nm of available bandwidth. However, as the number of wavelength channels increases, the need for wavelength conversion is becoming ever more pronounced. To perform the wavelength conversion, interferometric structures...... such as the monolithically integrated Mach-Zehnder interferometers (SOA-MZI) using semiconductor optical amplifiers as phase-shifting elements have proven excellent candidates. Here we present the conversion and transmission properties of a fully packaged device capable of wavelength conversion from C- to L-band having more...

  10. All-optical wavelength conversion by picosecond burst absorption in colloidal PbS quantum dots

    NARCIS (Netherlands)

    Geiregat, P.A.; Houtepen, A.J.; Van Thourhout, Dries; Hens, Zeger

    2016-01-01

    All-optical approaches to change the wavelength of a data signal are considered more energy-and cost-effective than current wavelength conversion schemes that rely on back and forth switching between the electrical and optical domains. However, the lack of cost-effective materials with

  11. Wavelength conversion of 80 Gb/s RZ-DPSK Pol-MUX signals in a silicon nanowire

    DEFF Research Database (Denmark)

    Vukovic, Dragana; Peucheret, Christophe; Oxenløwe, Leif Katsuo

    2014-01-01

    All-optical wavelength conversion of 80 Gb/s RZ-DPSK polarization multiplexed signals is demonstrated in a silicon nanowire using an angled-pump scheme. The quality of the converted signal is characterized through BER measurements for the first time.......All-optical wavelength conversion of 80 Gb/s RZ-DPSK polarization multiplexed signals is demonstrated in a silicon nanowire using an angled-pump scheme. The quality of the converted signal is characterized through BER measurements for the first time....

  12. All-Optical Wavelength Conversion of a High-Speed RZ-OOK Signal in a Silicon Nanowire

    DEFF Research Database (Denmark)

    Hu, Hao; Ji, Hua; Galili, Michael

    2011-01-01

    All-optical wavelength conversion of a 320 Gb/s line-rate RZ-OOK signal is demonstrated based on four-wave mixing in a 3.6 mm long silicon nanowire. Bit error rate measurements validate the performance within FEC limits.......All-optical wavelength conversion of a 320 Gb/s line-rate RZ-OOK signal is demonstrated based on four-wave mixing in a 3.6 mm long silicon nanowire. Bit error rate measurements validate the performance within FEC limits....

  13. All-Optical 9.35 Gb/s Wavelength Conversion in an InP Photonic Crystal Nanocavity

    DEFF Research Database (Denmark)

    Vukovic, Dragana; Yu, Yi; Heuck, Mikkel

    2013-01-01

    Wavelength conversion of a 9.35 Gb/s RZ signal is demonstrated using an InP photonic crystal H0 nanocavity. A clear eye is observed for the converted signal showing a pre-FEC bit error ratio down to 10-3.......Wavelength conversion of a 9.35 Gb/s RZ signal is demonstrated using an InP photonic crystal H0 nanocavity. A clear eye is observed for the converted signal showing a pre-FEC bit error ratio down to 10-3....

  14. Broadband Polarization-Insensitive Wavelength Conversion Based on Non-Degenerate Four-Wave Mixing in a Silicon Nanowire

    DEFF Research Database (Denmark)

    Pu, Minhao; Hu, Hao; Ji, Hua

    2012-01-01

    We experimentally demonstrate broadband polarization-insensitive one-to-two wavelength conversion of a 10-Gb/s DPSK data signal based on non-degenerate four-wave mixing in a silicon nanowire with bit-error rate measurements.......We experimentally demonstrate broadband polarization-insensitive one-to-two wavelength conversion of a 10-Gb/s DPSK data signal based on non-degenerate four-wave mixing in a silicon nanowire with bit-error rate measurements....

  15. Wavelength conversion of a 128 Gbit/s DP-QPSK signal in a silicon polarization diversity circuit

    DEFF Research Database (Denmark)

    Vukovic, Dragana; Schroeder, Jochen; Ding, Yunhong

    2014-01-01

    Wavelength conversion of a 128 Gbit/s DP-QPSK signal is demonstrated using FWM in a polarization diversity circuit with silicon nanowires as nonlinear elements. Error-free performances are achieved with a negligible power penalty.......Wavelength conversion of a 128 Gbit/s DP-QPSK signal is demonstrated using FWM in a polarization diversity circuit with silicon nanowires as nonlinear elements. Error-free performances are achieved with a negligible power penalty....

  16. On-chip all-optical wavelength conversion of multicarrier, multilevel modulation (OFDM m-QAM) signals using a silicon waveguide.

    Science.gov (United States)

    Li, Chao; Gui, Chengcheng; Xiao, Xi; Yang, Qi; Yu, Shaohua; Wang, Jian

    2014-08-01

    We report on-chip all-optical wavelength conversion of multicarrier multilevel modulation signals in a silicon waveguide. Using orthogonal frequency-division multiplexing (OFDM) combined with advanced multilevel quadrature amplitude modulation (QAM) signals (i.e., OFDM m-QAM), we experimentally demonstrate all-optical wavelength conversions of 3.2 Gbaud/s OFDM 16/32/64/128-QAM signals based on the degenerate four-wave mixing (FWM) nonlinear effect in a silicon waveguide. The measured optical signal-to-noise ratio (OSNR) penalties of wavelength conversion are ∼3  dB for OFDM 16-QAM and ∼4  dB for OFDM 32-QAM at 7% forward error correction (FEC) threshold and ∼3.5  dB for OFDM 64-QAM and ∼4.5  dB for OFDM 128-QAM at 20% FEC threshold. The observed clear constellations of converted idlers imply favorable performance obtained for silicon-waveguide-based OFDM 16/32/64/128-QAM wavelength conversions.

  17. Reconfigurable high-speed optical fibre networks: Optical wavelength conversion and switching using VCSELs to eliminate channel collisions

    Science.gov (United States)

    Boiyo, Duncan Kiboi; Chabata, T. V.; Kipnoo, E. K. Rotich; Gamatham, R. R. G.; Leitch, A. W. R.; Gibbon, T. B.

    2017-01-01

    We experimentally provide an alternative solution to channel collisions through up-wavelength conversion and switching by using vertical cavity surface-emitting lasers (VCSELs). This has been achieved by utilizing purely optical wavelength conversion on VCSELs at the low attenuation, 1550 nm transmission window. The corresponding transmission and bit error-rate (BER) performance evaluation is also presented. In this paper, two 1550 nm VCSELs with 50-150 GHz channel spacing are modulated with a 10 Gb/s NRZ PRBS 27-1 data and their interferences investigated. A channel interference penalty range of 0.15-1.63 dB is incurred for 150-50 GHz channel spacing without transmission. To avoid channel collisions and to minimize high interference penalties, the transmitting VCSEL with data is injected into the side-mode of a slave VCSEL to obtain a new up converted wavelength. A 16 dB extinction ratio of the incoming wavelength is achieved when a 15 dBm transmitting beam is injected into the side-mode of a -4.5 dBm slave VCSEL. At 8.5 Gb/s, a 1.1 dB conversion and a 0.5 dB transmission penalties are realized when the converted wavelength is transmitted over a 24.7 km G.655 fibre. This work offers a low-cost, effective wavelength conversion and channel switching to reduce channel collision probability by reconfiguring channels at the node of networks.

  18. Wavelength conversion of QAM signals in a low loss CMOS compatible spiral waveguide

    DEFF Research Database (Denmark)

    Da Ros, Francesco; Porto da Silva, Edson; Zibar, Darko

    2017-01-01

    We demonstrate wavelength conversion of quadrature amplitude modulation (QAM) signals, including 32-GBd quadrature phase-shift keying and 10-GBd 16-QAM, in a 50-cm long high index doped glass spiral waveguide. The quality of the generated idlers for up to 20 nm of wavelength shift is sufficient...... to achieve a BER performance below the hard decision forward error correction threshold BER performance (...

  19. Experimental demonstration of novel cascaded SFG+DFG wavelength conversion of picosecond pulses in LiNbO 3 waveguides

    Science.gov (United States)

    Wang, Jian; Sun, Junqiang; Luo, Chuanhong

    2006-06-01

    A novel cascaded χ (2) wavelength conversion of picosecond pulses based on sum frequency generation and difference frequency generation (SFG+DFG) is proposed and experimentally demonstrated in LiNbO 3 waveguides. The signal pulse with 40-GHz repetition rate and 1.57-ps pulse width is adopted. First of all, high conversion efficiency about -18.93dB can be achieved with low power level required for both two pump lights, which is greatly enhanced approximately 8dB compared with the conventional cascaded second-order nonlinear interactions (SHG+DFG) with a single and much higher power pump. Secondly, the wavelength of the converted idler wave can be tuned from 1527.4 to 1540.5nm when the signal wavelength is changed from 1561.9 to 1548.4nm, and about 13.1nm converted idler bandwidth is achieved with the conversion efficiency higher than -31dB. Thirdly, two pump wavelengths can be separated as large as 17.3nm. Meanwhile, when one pump wavelength is fixed at 1549.1nm, the other can be tuned within a wide wavelength range about 7.6nm with the conversion efficiency higher than -34dB, which is much larger than that in the SHG+DFG situation. Finally, the temporal waveform of the converted idler pulse is observed with rather clear appearance achieved, and no obvious changes of the pulse shape and width are found compared with its corresponding original injected signal, showing that our proposed scheme exhibits a very good conversion performance.

  20. Quantum manipulation of two-color stationary light: Quantum wavelength conversion

    International Nuclear Information System (INIS)

    Moiseev, S. A.; Ham, B. S.

    2006-01-01

    We present a quantum manipulation of a traveling light pulse using electromagnetically induced transparency-based slow light phenomenon for the generation of two-color stationary light. We theoretically discuss the two-color stationary light for the quantum wavelength conversion process in terms of pulse area, energy transfer, and propagation directions. The condition of the two-color stationary light pulse generation has been found and the quantum light dynamics has been studied analytically in the adiabatic limit. The quantum frequency conversion rate of the traveling light is dependent on the spatial spreading of the two-color stationary light pulse and can be near unity in an optically dense medium for the optimal frequencies of the control laser fields

  1. Terahertz-wave differential detection based on simultaneous dual-wavelength up-conversion

    Directory of Open Access Journals (Sweden)

    Yuma Takida

    2017-03-01

    Full Text Available We report a terahertz (THz-wave differential detection based on simultaneous dual-wavelength up-conversion in a nonlinear optical MgO:LiNbO3 crystal with optical and electronic THz-wave sources. The broadband parametric gain and noncollinear phase-matching of MgO:LiNbO3 provide efficient conversion from superposed THz waves to spatially distributed near-infrared (NIR beams to function as a dispersive THz-wave spectrometer without any additional dispersive element. We show that the μW-level THz waves from two independent sources, a 0.78-THz injection-seeded THz-wave parametric generator (is-TPG and a 1.14-THz resonant tunneling diode (RTD, are simultaneously up-converted to two NIR waves and then detected with two NIR photodetectors. By applying a balanced detection scheme to this dual-frequency detection, we demonstrate THz-wave differential imaging of maltose and polyethylene pellets in the transmission geometry. This dual-wavelength detection is applicable to more than three frequencies and broadband THz-wave radiation for real-time THz-wave spectroscopic detection and imaging.

  2. Wavelength converter technology

    DEFF Research Database (Denmark)

    Kloch, Allan; Hansen, Peter Bukhave; Poulsen, Henrik Nørskov

    1999-01-01

    Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers.......Wavelength conversion is important since it ensures full flexibility of the WDM network layer. Progress in optical wavelength converter technology is reviewed with emphasis on all-optical wavelength converter types based on semiconductor optical amplifiers....

  3. All optical wavelength conversion and parametric amplification in Ti:PPLN channel waveguides for telecommunication applications

    Energy Technology Data Exchange (ETDEWEB)

    Nouroozi, Rahman

    2010-10-19

    Efficient ultra-fast integrated all-optical wavelength converters and parametric amplifiers transparent to the polarization, phase, and modulation-level and -format are investigated. The devices take advantage of the optical nonlinearity of Ti:PPLN waveguides exploiting difference frequency generation (DFG). In a DFG, the signal ({lambda}{sub s}) is mixed with a pump ({lambda}{sub p}) to generate a wavelength shifted idler (1/{lambda}{sub i}=1/{lambda}{sub p}-1/{lambda}{sub s}). Efficient generation of the pump in Ti:PPLN channel guides is investigated using different approaches. In the waveguide resonators, first a resonance of the fundamental wave alone is considered. It is shown that the maximum power enhancement of the fundamental wave, and therefore the maximum second-harmonic generation (SHG) efficiency, can be achieved with low loss matched resonators. By this way, SHG efficiency of {proportional_to}10300%/W (10.3 %/mW) has been achieved in a 65 mm long waveguide resonator. Its operation for cSHG/DFG requires narrowband reflector for fundamental wave only. Thus, the SH (pump) wave resonator is investigated. The SH-wave resonator enhances the intracavity SH power only. Based on this scheme, an improvement of {proportional_to}10 dB for cSHG/DFG based wavelength conversion efficiency has been achieved with 50 mW of coupled fundamental power in a 30 mm long Ti:PPLN. However, operation was limited to relatively small fundamental power levels (<50 mW) due to the onset of photorefractive instabilities destroying the cavity stabilization. The cSHG/DFG efficiency can be considerably improved by using a double-pass configuration in which all the interacting waves were reflected by a broadband dielectric mirror deposited on the one endface of the waveguide. Three different approaches are investigated and up to 9 dB improvement of the wavelength conversion efficiency in comparison with the single-pass configuration is achieved. Polarization-insensitive wavelength

  4. Optimized Wavelength-Tuned Nonlinear Frequency Conversion Using a Liquid Crystal Clad Waveguide

    Science.gov (United States)

    Stephen, Mark A. (Inventor)

    2018-01-01

    An optimized wavelength-tuned nonlinear frequency conversion process using a liquid crystal clad waveguide. The process includes implanting ions on a top surface of a lithium niobate crystal to form an ion implanted lithium niobate layer. The process also includes utilizing a tunable refractive index of a liquid crystal to rapidly change an effective index of the lithium niobate crystal.

  5. AlGaAs-On-Insulator Nanowire with 750 nm FWM Bandwidth, -9 dB CW Conversion Efficiency, and Ultrafast Operation Enabling Record Tbaud Wavelength Conversion

    DEFF Research Database (Denmark)

    Pu, Minhao; Ottaviano, Luisa; Semenova, Elizaveta

    2015-01-01

    We present an AlGaAs-on-insulator platform for integrated nonlinear photonics. We demonstrate the highest reported conversion efficiency/length/pump-power, ultra-broadband fourwave mixing, and first-ever wavelength conversion of 1.28-Tbaud serial data signals in a 3-mm long dispersion-engineered AlGa...

  6. Mode-selective wavelength conversion based on four-wave mixing in a multimode silicon waveguide

    DEFF Research Database (Denmark)

    Ding, Yunhong; Xu, Jing; Ou, Haiyan

    2014-01-01

    to phase mismatch. A two-mode division multiplexing circuit with tapered directional coupler based (de)multiplexers and a multimode waveguide is designed and fabricated for this application. Experimental results show clear eye-diagrams and moderate power penalties for the wavelength conversion of both...

  7. Mode-Selective Wavelength Conversion Based on Four-Wave Mixing in a Multimode Silicon Waveguide

    DEFF Research Database (Denmark)

    Ding, Yunhong; Xu, Jing; Ou, Haiyan

    2013-01-01

    We report all-optical mode-selective wavelength conversion based on four-wave mixing in a multimode Si waveguide. A two-mode division multiplexing circuit using tapered directional coupler based (de)multiplexers is used for the application. Experimental results show clear eye-diagrams and moderate...

  8. Wavelength converter placement for different RWA algorithms in wavelength-routed all-optical networks

    Science.gov (United States)

    Chu, Xiaowen; Li, Bo; Chlamtac, Imrich

    2002-07-01

    Sparse wavelength conversion and appropriate routing and wavelength assignment (RWA) algorithms are the two key factors in improving the blocking performance in wavelength-routed all-optical networks. It has been shown that the optimal placement of a limited number of wavelength converters in an arbitrary mesh network is an NP complete problem. There have been various heuristic algorithms proposed in the literature, in which most of them assume that a static routing and random wavelength assignment RWA algorithm is employed. However, the existing work shows that fixed-alternate routing and dynamic routing RWA algorithms can achieve much better blocking performance. Our study in this paper further demonstrates that the wavelength converter placement and RWA algorithms are closely related in the sense that a well designed wavelength converter placement mechanism for a particular RWA algorithm might not work well with a different RWA algorithm. Therefore, the wavelength converter placement and the RWA have to be considered jointly. The objective of this paper is to investigate the wavelength converter placement problem under fixed-alternate routing algorithm and least-loaded routing algorithm. Under the fixed-alternate routing algorithm, we propose a heuristic algorithm called Minimum Blocking Probability First (MBPF) algorithm for wavelength converter placement. Under the least-loaded routing algorithm, we propose a heuristic converter placement algorithm called Weighted Maximum Segment Length (WMSL) algorithm. The objective of the converter placement algorithm is to minimize the overall blocking probability. Extensive simulation studies have been carried out over three typical mesh networks, including the 14-node NSFNET, 19-node EON and 38-node CTNET. We observe that the proposed algorithms not only outperform existing wavelength converter placement algorithms by a large margin, but they also can achieve almost the same performance comparing with full wavelength

  9. All-optical wavelength conversion at bit rates above 10 Gb/s using semiconductor optical amplifiers

    DEFF Research Database (Denmark)

    Jørgensen, Carsten; Danielsen, Søren Lykke; Stubkjær, Kristian

    1997-01-01

    This work assesses the prospects for high-speed all-optical wavelength conversion using the simple optical interaction with the gain in semiconductor optical amplifiers (SOAs) via the interband carrier recombination. Operation and design guidelines for conversion speeds above 10 Gb/s are described...... and the various tradeoffs are discussed. Experiments at bit rates up to 40 Gb/s are presented for both cross-gain modulation (XGM) and cross-phase modulation (XPM) in SOAs demonstrating the high-speed capability of these techniques...

  10. Experimental demonstration of wavelength conversion between ps-pulses based on cascaded sum- and difference frequency generation (SFG+DFG) in LiNbO3 waveguides

    Science.gov (United States)

    Wang, Jian; Sun, Junqiang; Lou, Chuanhong; Sun, Qizhen

    2005-09-01

    All-optical wavelength conversion between ps-pulses based on cascaded sum- and difference frequency generation (SFG+DFG) is proposed and experimentally demonstrated in periodically poled LiNbO3 (PPLN) waveguides. The signal pulse with 40-GHz repetition rate and 1.57- ps pulse width is adopted. The converted idler wavelength can be tuned from 1527.4 to 1540.5nm as the signal wavelength is varied from 1561.9 to 1548.4nm. No obvious changes of the pulse shape and width, also no chirp are observed in the converted idler pulse. The results imply that single-to-multiple channel wavelength conversions can be achieved by appropriately tuning the two pump wavelengths.

  11. Dose conversion factors

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1992-01-01

    The following is discussed in this report: concepts and quantities used in calculating radiation dose from internal and external exposure. Tabulations of dose conversion factor for internal and external exposure to radionuclides. Dose conversion factors give dose per unit intake (internal) or dose per unit concentration in environment (external). Intakes of radionuclides for internal exposure and concentrations of radionuclides in environment for external exposure are assumed to be known. Intakes and concentrations are obtained, e.g., from analyses of environmental transport and exposure pathways. differences between dosimetry methods for radionuclides and hazardous chemicals are highlighted

  12. Conversion factors and oil statistics

    International Nuclear Information System (INIS)

    Karbuz, Sohbet

    2004-01-01

    World oil statistics, in scope and accuracy, are often far from perfect. They can easily lead to misguided conclusions regarding the state of market fundamentals. Without proper attention directed at statistic caveats, the ensuing interpretation of oil market data opens the door to unnecessary volatility, and can distort perception of market fundamentals. Among the numerous caveats associated with the compilation of oil statistics, conversion factors, used to produce aggregated data, play a significant role. Interestingly enough, little attention is paid to conversion factors, i.e. to the relation between different units of measurement for oil. Additionally, the underlying information regarding the choice of a specific factor when trying to produce measurements of aggregated data remains scant. The aim of this paper is to shed some light on the impact of conversion factors for two commonly encountered issues, mass to volume equivalencies (barrels to tonnes) and for broad energy measures encountered in world oil statistics. This paper will seek to demonstrate how inappropriate and misused conversion factors can yield wildly varying results and ultimately distort oil statistics. Examples will show that while discrepancies in commonly used conversion factors may seem trivial, their impact on the assessment of a world oil balance is far from negligible. A unified and harmonised convention for conversion factors is necessary to achieve accurate comparisons and aggregate oil statistics for the benefit of both end-users and policy makers

  13. Tunable All-Optical Wavelength Conversion Based on Cascaded SHG/DFG in a Ti:PPLN Waveguide Using a Single CW Control Laser

    DEFF Research Database (Denmark)

    Hu, Hao; Nouroozi, Rahman; Wang, Wenrui

    2012-01-01

    Tunable all-optical wavelength conversion (AOWC) of a 40-Gb/s RZ-OOK data signal based on cascaded second-harmonic generation (SHG) and difference-frequency generation (DFG) in a Ti:PPLN waveguide is demonstrated. Error-free performances with negligible power penalty are achieved for the wavelength...

  14. Parametric amplification and wavelength conversion of a 2.048-Tbit/s WDM PDM 16-QAM signal

    DEFF Research Database (Denmark)

    Hu, Hao; Jopson, R. M.; Gnauck, A. H.

    2014-01-01

    We demonstrate polarisation-insensitive parametric amplification in highly nonlinear fibre of a 2.048-Tbit/s dense WDM PDM 16-QAM signal with ∼10 dB on-off gain and simultaneous wavelength conversion and phase conjugation, with mean Q2 penalties of only 0.6 dB and 0.4 dB....

  15. A 1550-nm all-optical VCSEL-to-VCSEL wavelength conversion of a 8.5-Gb/s data signal and transmission over a 24.7-km fibre

    Science.gov (United States)

    Boiyo, D. Kiboi; Isoe, G. M.; Gamatham, R. R. G.; Leitch, A. W. R.; Gibbon, T. B.

    2016-02-01

    For the first time, we demonstrate, VCSEL-to-VCSEL wavelength conversion within the low attenuation 1550 nm window, including transmission over fibre and bit error rate (BER) performance characterization. We experimentally demonstrate a low injection power optical wavelength conversion by injecting an optical beam from a signal carrier master vertical cavity surface-emitting laser (VCSEL) into the side-mode of the slave VCSEL. This technique solves the challenge of wavelength collisions and also provides wavelength re-use in typical wavelength division multiplexed (WDM) systems. This paper, for the first time, uses two 1550 nm VCSELs with tunability range of 3 nm for a 5-9.8 mA bias current. The master VCSEL is modulated with a non-return-to-zero (NRZ) pseudo-random binary sequence (PRBS_27-1) 8.5 Gb/s data. A data conversion penalty of 1.1 dB is realized when a 15 dBm injection beam is used. The transmission performance of the converted wavelength from the slave VCSEL is evaluated using BER measurement at a 10-9 threshold. A 0.5 dB transmission penalty of the converted wavelength data is realized in an 8.5 Gb/s transmission over 24.7 km. This work is vital for optical fibre systems that may require wavelength switching for transmission of data signals.

  16. Wavelength conversion of a 40 Gb/s RZ-DPSK signal using four-wave mixing in a dispersion-flattened highly nonlinear photonic crystal fiber

    DEFF Research Database (Denmark)

    Andersen, Peter Andreas; Tokle, Torger; Geng, Yan

    2005-01-01

    Wavelength conversion of a 40-Gb/s return-to-zero differential phase-shift keying signal is demonstrated in a highly nonlinear photonic crystal fiber (HNL-PCF) for the first time. A conversion efficiency of -20 dB for a pump power of 23 dBm and a conversion bandwidth of 31 nm, essentially limited...

  17. Parametric Amplification, Wavelength Conversion, and Phase Conjugation of a 2.048-Tbit/s WDM PDM 16-QAM Signal

    DEFF Research Database (Denmark)

    Hu, Hao; Jopson, R. M.; Gnauck, A. H.

    2015-01-01

    We demonstrate polarization-independent parametric amplification of a 2.048-Tbit/s 8-WDM PDM 16-QAM signal and simultaneous wavelength conversion and phase conjugation in a highly nonlinear fiber. Two high-power continuous-wave pumps with orthogonal polarizations and counter-phase modulation are ...

  18. Wavelength-Converter Saving Span Restoration in GMPLS Controlled WDM Optical Networks

    DEFF Research Database (Denmark)

    Ruepp, Sarah Renée; Buron, Jakob Due; Andriolli, N.

    2006-01-01

    We present two label preference schemes to reduce wavelength-conversion during restoration path setup in GMPLS controlled optical networks exploiting span restoration. The amount of required wavelength-conversions can be reduced up to 34 percent.......We present two label preference schemes to reduce wavelength-conversion during restoration path setup in GMPLS controlled optical networks exploiting span restoration. The amount of required wavelength-conversions can be reduced up to 34 percent....

  19. 4 × 10 Gb s−1 wavelength multicasting with tunable NRZ-to-RZ format conversion using nonlinear polarization rotation in an SOA

    International Nuclear Information System (INIS)

    Liu, S; Fu, S; Tang, M; Shum, P; Liu, D

    2013-01-01

    We experimentally demonstrate simultaneous 4 × 10 Gb s −1 all-optical wavelength multicasting and non-return-to-zero (NRZ)-on-off-keying (OOK) to return-to-zero (RZ)-OOK format conversion with a tunable duty cycle using nonlinear polarization rotation in a semiconductor optical amplifier (SOA). The experimental results show that the duty cycle of four converted RZ-OOK signals can be tuned by adjusting the orientation of a polarizer placed at the SOA output. Four-channel NRZ-OOK-to-RZ-OOK conversion with a full width at half maximum of 33–67 ps can be simultaneously obtained with an extinction ratio over 10 dB. Moreover, it is experimentally verified that such a wavelength multicasting scheme with simultaneous NRZ-OOK-to-RZ-OOK conversion is insensitive to the wavelength of the input signal, indicating that such a scheme can be operated in the whole C-band with less than 0.18 dB power penalty at a bit error ratio level of 10 −9 . The device can facilitate the cross-connection between optical transmission networks employing different modulation formats. (paper)

  20. Wavelength Conversion of a 9.35-Gb/s RZ OOK Signal in an InP Photonic Crystal Nanocavity

    DEFF Research Database (Denmark)

    Vukovic, Dragana; Yu, Yi; Heuck, Mikkel

    2014-01-01

    Wavelength conversion of a 10-Gb/s (9.35 Gb/s net rate) return-to-zero ON-OFF keying signal is demonstrated using a simple InP photonic crystal H0 nanocavity with Lorentzian line shape. The shifting of the resonance induced by the generation of free-carriers enables the pump intensity modulation...

  1. Wavelength conversion, time demultiplexing and multicasting based on cross-phase modulation and four-wave mixing in dispersion-flattened highly nonlinear photonic crystal fiber

    International Nuclear Information System (INIS)

    Hui, Zhan-Qiang; Zhang, Jian-Guo

    2012-01-01

    We propose the use of cross-phase modulation (XPM) and four-wave mixing (FWM) in dispersion-flattened highly nonlinear photonic crystal fibers (HNL-PCFs) to implement the functionalities of wavelength conversion, simultaneous time demultiplexing and wavelength multicasting in optical time-division multiplexing (OTDM) systems. The experiments on wavelength conversion at 80 Gbit s −1 and OTDM demultiplexing from 80 to 10 Gbit s −1 with wavelength multicasting of two channels are successfully demonstrated to validate the proposed scheme, which are carried out by using two segments of dispersion-flattened HNL-PCFs with lengths of 100 and 50 m, respectively. Moreover, the bit error rate (BER) performance is also measured. The results show that our designed system can achieve a power penalty of less than 4.6 dB for two multicasting channels with a 24 nm wavelength span at the BER of 10 −9 when compared with the 10 Gbit/s back-to-back measurement. The proposed system is transparent to bit rate since only an ultrafast third-order nonlinear effect is used. The resulting configuration is compact, robust and reliable, benefiting from the use of dispersion-flattened HNL-PCFs with short lengths. This also makes the proposed system more flexible in the operational wavelengths than those based on dispersion-shifted fibers and traditional highly nonlinear fibers. (paper)

  2. Simultaneous wavelength and format conversion in SDN/NFV for flexible optical network based on FWM in SOA

    Science.gov (United States)

    Zhan, Yueying; Wang, Danshi; Zhang, Min

    2018-04-01

    We propose an all-optical wavelength and format conversion model (CM) for a dynamic data center interconnect node and coherent passive optical network (PON) optical network unit (ONU) in software-defined networking and network function virtualization system based on four-wave mixing in a semiconductor optical amplifier. Five wavelength converted DQPSK signals and two format converted DPSK signals are generated; the performances of the generated signals for two strategies of setting CM in the data center interconnect node and coherent PON ONU, which are over 10 km fiber transmission, have been verified. All of the converted signals are with a power penalty less than 2.2 dB at FEC threshold of 3.8 × 10 - 3, and the optimum bias current of SOA is 300 mA.

  3. Estimates of external dose-rate conversion factors and internal dose conversion factors for selected radionuclides released from fusion facilities

    Energy Technology Data Exchange (ETDEWEB)

    Homma, Toshimitsu; Togawa, Orihiko [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    1996-11-01

    This report provides a tabulation of both external dose-rate conversion factors and internal dose conversion factors using radioactive decay data in the updated Evaluated Nuclear Structure Data File (ENSDF) for selected 26 radionuclides and all their daughter radionuclides of potential importance in safety assessments of fusion facilities. The external dose-rate conversion factors for 21 target organs are tabulated for three exposure modes that are immersion in contaminated air, irradiation at a height of 1 m above a contaminated ground surface and immersion contaminated water. For internal exposure, committed dose equivalents, based on the methodology of ICRP Publication 30, in the same target organs per intake of unit activity are given for the inhalation and ingestion exposure pathways. The data presented here is intended to be generally used for safety assessments of fusion reactors. Comparisons of external effective dose-rate conversion factors and committed effective dose equivalents are made with the previous data from the independent data bases to provide quality assurance on our calculated results. There is generally good agreement among data from the independent data bases. The differences in the values of both effective dose-rate and dose conversion factors appeared are primarily due to differences in calculational methodology, the use of different radioactive decay data, and compilation errors. (author)

  4. Proposal concerning the absorbed dose conversion factor

    Energy Technology Data Exchange (ETDEWEB)

    Shiragai, A [National Inst. of Radiological Sciences, Chiba (Japan)

    1978-03-01

    New definitions of the absorbed dose conversion factors Csub(lambda) and Csub(E) are proposed. The absorbed dose in water is given by the product of absorbed dose conversion factor, exposure calibration factor, ionisation chamber reading, cap displacement correction factor and perturbation correction factor. At exposure calibration the material of the build-up cap must be the same as that of the chamber wall. An ionisation chamber of which the wall material is water-equivalent or air-equivalent may be used. In the latter case the wall must be thin. For these two cases absorbed dose conversion factors are introduced and it is recommended that either of the two sets should be adopted. Furthermore, if the chamber wall is neither water- nor air-equivalent, the factor by which these currently defined values should be multiplied is also given: again the wall must be thin. The ICRU definitions of Csub(lambda) and Csub(E) are inconsistent, as recently pointed out, while the definitions presented here are consistent.

  5. 42 CFR 414.30 - Conversion factor update.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Conversion factor update. 414.30 Section 414.30... Practitioners § 414.30 Conversion factor update. Unless Congress acts in accordance with section 1848(d)(3) of... preceding FY over the third preceding FY exceeds the performance standard rate of increase established for...

  6. Travelling-wave resonant four-wave mixing breaks the limits of cavity-enhanced all-optical wavelength conversion.

    Science.gov (United States)

    Morichetti, Francesco; Canciamilla, Antonio; Ferrari, Carlo; Samarelli, Antonio; Sorel, Marc; Melloni, Andrea

    2011-01-01

    Wave mixing inside optical resonators, while experiencing a large enhancement of the nonlinear interaction efficiency, suffers from strong bandwidth constraints, preventing its practical exploitation for processing broad-band signals. Here we show that such limits are overcome by the new concept of travelling-wave resonant four-wave mixing (FWM). This approach combines the efficiency enhancement provided by resonant propagation with a wide-band conversion process. Compared with conventional FWM in bare waveguides, it exhibits higher robustness against chromatic dispersion and propagation loss, while preserving transparency to modulation formats. Travelling-wave resonant FWM has been demonstrated in silicon-coupled ring resonators and was exploited to realize a 630-μm-long wavelength converter operating over a wavelength range wider than 60 nm and with 28-dB gain with respect to a bare waveguide of the same physical length. Full compatibility of the travelling-wave resonant FWM with optical signal processing applications has been demonstrated through signal retiming and reshaping at 10 Gb s(-1).

  7. Factors determining conversion of laparoscopic to open cholecystectomy

    Directory of Open Access Journals (Sweden)

    Tapash Kumar Maitra

    2017-07-01

    Full Text Available Background and objectives:Laparoscopic cholecystectomy (LC has virtually replaced conventional open cholecystectomy (OC as the standard procedure of treatment for cholelithiasis and cholecystitis. However, OC sometimes becomes a necessity considering the feasibility and safety of the surgical procedure. But the factors that demand conversion from LC to OC differ widely. The present study aimed to determine the prevalence of conversion from LC to OC and to assess the causes of conversion and risk factors related to conversion. Methods: The study was conducted in a referral hospital – ‘Bangladesh Institute of Research and Rehabilitation in Diabetes, Endocrine and Metabolic Disorder (BIRDEM’ from September 2014 to September 2016. Cases of cholelithiasis with or without cholecystitis, and other gall bladder pathology were included in the study. A team of experienced surgeon performed LC of all selected cases. The causes of conversion to OC were systematically recorded by the surgical team and the risk factors (age, sex, obesity, history of previous abdominal surgery, gallbladder thickness related to conversion from LC to OC was investigated. Results: A total of 261 (M / F = 87 /174 patients were considered eligible for the study. The mean age of all patients was 43 (±1.75 years. For the male and female groups the mean ages were 44±1.9 and 42±1.6 years respectively. Of the total 261 cases, 210 (80.5% patients had cholelithiasis with chronic cholecystitis, 47 (18.0% had gallbladder stone plus acute cholecystitis and 4 (1.5% had gallbladder polyp. Open conversion was required in case of 19 patients. Thus, overall conversion rate was 7.3%. The common causes of conversion were a difficulty in defining Calot’s triangle (42.1%, b injury to cystic artery (21.1% and c injury to bile duct (15.8%. Both male and female had equal risk for conversion. The investigated risk factors like history of previous abdominal surgery, preoperative ERCP, acute

  8. The conversion factor of α radiation efficiency

    International Nuclear Information System (INIS)

    Wang Weida; Zhou Zhixin; Xia Junding

    1997-01-01

    It is important in fine-grain TL dating that the full α dose must be converted into the equivalent β dose. Although the conversion coefficient K for internal radiation efficiency can not be measured directly for each sample, it is possible to measure the external radiation efficiency K 3.7 . For this purpose a special study for the conversion factor of K to K 3.7 has been made using ultrathin TLD. The results show that the conversion factor of the TLD for archaeological samples is 0.847, which is in agreement with the calculated value 0.85

  9. QPSK-to-2×BPSK wavelength and modulation format conversion through phase-sensitive four-wave mixing in a highly nonlinear optical fiber

    DEFF Research Database (Denmark)

    Da Ros, Francesco; Dalgaard, Kjeld; Lei, Lei

    2013-01-01

    A phase-sensitive four-wave mixing (FWM) scheme enabling the simultaneous conversion of the two orthogonal quadratures of an optical signal to different wavelengths is demonstrated for the first time under dynamic operation using a highly nonlinear optical fiber (HNLF) as the nonlinear medium...

  10. Dual-polarization wavelength conversion of 16-QAM signals in a single silicon waveguide with a lateral p-i-n diode [Invited

    DEFF Research Database (Denmark)

    Da Ros, Francesco; Gajda, Andrzej; Liebig, Erik

    2018-01-01

    with an optical signal-to-noise ratio penalty below 0.7 dB. High-quality converted signals are generated thanks to the low polarization dependence (≤0.5 dB) and the high conversion efficiency (CE) achievable. The strong Kerr nonlinearity in silicon and the decrease of detrimental free-carrier absorption due......A polarization-diversity loop with a silicon waveguide with a lateral p-i-n diode as a nonlinear medium is used to realize polarization insensitive four-wave mixing. Wavelength conversion of seven dual-polarization 16-quadrature amplitude modulation (QAM) signals at 16 GBd is demonstrated...

  11. Conversion Factors for Predicting Unshielded Dose Rates in Shielded Waste

    International Nuclear Information System (INIS)

    Clapham, M.; Seamans Jr, J.V.; Arbon, R.E.

    2009-01-01

    This document describes the methodology developed and used by the Advanced Mixed Waste Treatment Project for determining the activity content and the unshielded surface dose rate for lead lined containers contaminated with transuranic waste. Several methods were investigated: - Direct measurement of the dose rate after removing the shielding. - Use of a MicroShield R derived dose conversion factor, (mRem/hr unshielded )/(mRem/hr shielded ), applied to the measured surface dose rate to estimate the unshielded surface dose rate. - Use of a MicroShield R derived activity conversion factor, mRem/hr unshielded /Ci, applied to the measured activity to estimate the unshielded dose rate. - Use of an empirically derived activity conversion factor, mRem/hr unshielded /Ci, applied to the measured activity to estimate the unshielded dose rate. The last approach proved to be the most efficacious by using a combination of nondestructive assay and empirically defined dose rate conversion factors. Empirically derived conversion factors were found to be highly dependent upon the matrix of the waste. Use of conversion factors relied on activity values corrected to address the presence of a lead liner. (authors)

  12. Multicast routing for wavelength-routed WDM networks with dynamic membership

    Science.gov (United States)

    Huang, Nen-Fu; Liu, Te-Lung; Wang, Yao-Tzung; Li, Bo

    2000-09-01

    Future broadband networks must support integrated services and offer flexible bandwidth usage. In our previous work, we explore the optical link control layer on the top of optical layer that enables the possibility of bandwidth on-demand service directly over wavelength division multiplexed (WDM) networks. Today, more and more applications and services such as video-conferencing software and Virtual LAN service require multicast support over the underlying networks. Currently, it is difficult to provide wavelength multicast over the optical switches without optical/electronic conversions although the conversion takes extra cost. In this paper, based on the proposed wavelength router architecture (equipped with ATM switches to offer O/E and E/O conversions when necessary), a dynamic multicast routing algorithm is proposed to furnish multicast services over WDM networks. The goal is to joint a new group member into the multicast tree so that the cost, including the link cost and the optical/electronic conversion cost, is kept as less as possible. The effectiveness of the proposed wavelength router architecture as well as the dynamic multicast algorithm is evaluated by simulation.

  13. Calculation of neutron fluence-to-dose conversion factors for extremities

    International Nuclear Information System (INIS)

    Stewart, R.D.; Harty, R.; McDonald, J.C.; Tanner, J.E.

    1993-04-01

    The Pacific Northwest Laboratory is developing a standard for the performance testing of personnel extremity dosimeters for the US Department of Energy. Part of this effort requires the calculation of neutron fluence-to-dose conversion factors for finger and wrist extremities. This study focuses on conversion factors for two types of extremity models: namely the polymethyl methacrylate (PMMA) phantom (as specified in the draft standard for performance testing of extremity dosimeters) and more realistic extremity models composed of tissue-and-bone. Calculations for each type of model are based on both bare and D 2 O-moderated 252 Cf sources. The results are then tabulated and compared with whole-body conversion factors. More appropriate energy-averaged quality factors for the extremity models have also been computed from the neutron fluence in 50 equally spaced energy bins with energies from 2.53 x 10 -8 to 15 MeV. Tabulated results show that conversion factors for both types of extremity phantom are 15 to 30% lower than the corresponcung whole-body phantom conversion factors for 252 Cf neutron sources. This difference in extremity and whole-body conversion factors is attributable to the proportionally smaller amount of back-scattering that occurs in the extremity phantoms compared with whole-body phantoms

  14. All-optical 40 Gbit/s compact integrated interferometric wavelength converter

    DEFF Research Database (Denmark)

    Jørgensen, Carsten; Danielsen, Søren Lykke; Hansen, Peter Bukhave

    1997-01-01

    An interferometric Michelson wavelength converter is presented that combines a speed-optimized semiconductor optical amplifier technology with the benefits of the integrated interferometer showing 40-Gbit/s wavelength conversion. The optimized wavelength converter demonstrates noninverted converted...

  15. Synchronous optical packet switch architecture with tunable single and multi-channels wavelength converters

    Science.gov (United States)

    Hamza, Haitham S.; Adel, Reham

    2017-07-01

    In this paper, we propose a bufferless synchronous optical packet switch (OPS) architecture named the Limited-range wavelength conversion with Dynamic Pump-wavelength Selection (LDPS) architecture. LDPS is equipped with a dedicated limited-range wavelength converters (LRWCs, and a shared pool of parametric wavelength converters (PWCs) with dynamic pump-wavelength selection (DPS). The adoption of hybrid conversion types in the proposed architecture aims at improving the packet loss rate (PLR) compared to conventional architecture with single conversion types, while reducing (or at least maintaining) the conversion distance (d) of used wavelength converters. Packet contention in the proposed architecture is resolved using the first available algorithm (FAA) and the dynamic pump-wavelength selection algorithm (DPSA). The performance of the proposed architecture is compared to two well-known conventional architectures; namely, the LRWC architecture that uses dedicated LRWCS for each input wavelength, and the DPS architecture that uses a shared pool of dynamic pump-wavelength converters (PWCs). Simulation results show that, for the same value of d, the new architecture reduces the PLR compared to the LRWC architecture by up to 40 % and 99.7 % for traffic loads, 0.5 and 1; respectively. In addition, for d = 1 , the new architecture reduces the PLR compared to the DPS architecture by up to 10 % and 99.3 % for traffic loads, 0.5 and 1; respectively.

  16. All-optical logic gates and wavelength conversion via the injection locking of a Fabry-Perot semiconductor laser

    Science.gov (United States)

    Harvey, E.; Pochet, M.; Schmidt, J.; Locke, T.; Naderi, N.; Usechak, N. G.

    2013-03-01

    This work investigates the implementation of all-optical logic gates based on optical injection locking (OIL). All-optical inverting, NOR, and NAND gates are experimentally demonstrated using two distributed feedback (DFB) lasers, a multi-mode Fabry-Perot laser diode, and an optical band-pass filter. The DFB lasers are externally modulated to represent logic inputs into the cavity of the multi-mode Fabry-Perot slave laser. The input DFB (master) lasers' wavelengths are aligned with the longitudinal modes of the Fabry-Perot slave laser and their optical power is used to modulate the injection conditions in the Fabry-Perot slave laser. The optical band-pass filter is used to select a Fabry- Perot mode that is either suppressed or transmitted given the logic state of the injecting master laser signals. When the input signal(s) is (are) in the on state, injection locking, and thus the suppression of the non-injected Fabry-Perot modes, is induced, yielding a dynamic system that can be used to implement photonic logic functions. Additionally, all-optical photonic processing is achieved using the cavity-mode shift produced in the injected slave laser under external optical injection. The inverting logic case can also be used as a wavelength converter — a key component in advanced wavelength-division multiplexing networks. As a result of this experimental investigation, a more comprehensive understanding of the locking parameters involved in injecting multiple lasers into a multi-mode cavity and the logic transition time is achieved. The performance of optical logic computations and wavelength conversion has the potential for ultrafast operation, limited primarily by the photon decay rate in the slave laser.

  17. Conversion factors for estimating release rate of gaseous radioactivity by an aerial survey

    International Nuclear Information System (INIS)

    Saito, Kimiaki; Moriuchi, Shigeru

    1988-02-01

    Conversion factors necessary for estimating release rate of gaseous radioactivity by an aerial survey are presented. The conversion factors were determined based on calculation assuming a Gaussian plume model as a function of atmospheric stability, down-wind distance and flight height. First, the conversion factors for plumes emitting mono-energy gamma rays were calculated, then, conversion factors were constructed through convolution for the radionuclides essential in an accident of a nuclear reactor, and for mixtures of these radionuclides considering elapsed time after shutdown. These conversion factors are shown in figures, and also polynomial expressions of the conversion factors as a function of height have been decided with the least-squares method. A user can easily obtain proper conversion factors from data shown here. (author)

  18. Psychosocial Factors in Children and Adolescents with Conversion Disorder

    Science.gov (United States)

    Sharma, I.; Giri, D.; Dutta, Anna; Mazumder, P.

    2005-01-01

    Introduction: In view of the limited studies on the psychosocial environment of children presenting with conversion disorders, the present study was carried out to study the psychosocial factors in children with conversion disorders. Method: 40 patients of Conversion Disorder, who presented with "pseudo seizures" and were diagnosed…

  19. Nominal Performance Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    M.A. Wasiolek

    2005-01-01

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the groundwater exposure scenario, and the development of conversion factors for assessing compliance with the groundwater protection standards. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop BDCFs, which are input parameters for the TSPA-LA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the ''Biosphere Model Report'' in Figure 1-1, contain detailed description of the model input parameters, their development, and the relationship between the parameters and specific features events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the groundwater exposure scenario. This analysis receives direct input from the outputs of the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) and the five analyses that develop parameter values for the biosphere model (BSC 2005 [DIRS 172827]; BSC 2004 [DIRS 169672]; BSC 2004 [DIRS 169673]; BSC 2004 [DIRS 169458]; BSC 2004 [DIRS 169459]). The results of this report are further analyzed in the ''Biosphere Dose Conversion Factor Importance and Sensitivity Analysis'' (Figure 1-1). The objectives of this analysis are to develop BDCFs for the

  20. Nominal Performance Biosphere Dose Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M.A. Wasiolek

    2003-07-25

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the groundwater exposure scenario, and the development of conversion factors for assessing compliance with the groundwater protection standard. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA model. The ''Biosphere Model Report'' (BSC 2003 [DIRS 164186]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports (BSC 2003 [DIRS 160964]; BSC 2003 [DIRS 160965]; BSC 2003 [DIRS 160976]; BSC 2003 [DIRS 161239]; BSC 2003 [DIRS 161241]) contain detailed description of the model input parameters. This report describes biosphere model calculations and their output, the BDCFs, for the groundwater exposure scenario. The objectives of this analysis are to develop BDCFs and conversion factors for the TSPA. The BDCFs will be used in performance assessment for calculating annual doses for a given concentration of radionuclides in groundwater. The conversion factors will be used for calculating gross alpha particle activity in groundwater and the annual dose from beta- and photon-emitting radionuclides.

  1. All-optical wavelength converter based on fiber cross-phase modulation and fiber Bragg grating

    Czech Academy of Sciences Publication Activity Database

    Honzátko, Pavel

    2010-01-01

    Roč. 283, č. 9 (2010), s. 1744-1749 ISSN 0030-4018 R&D Projects: GA AV ČR 1ET300670502 Institutional research plan: CEZ:AV0Z20670512 Keywords : Wavelength conversion * Fiber cross phase modulation * Fiber Bragg grating Subject RIV: BH - Optics, Masers, Lasers Impact factor: 1.517, year: 2010

  2. Derivation of dose conversion factors for tritium

    Energy Technology Data Exchange (ETDEWEB)

    Killough, G. G.

    1982-03-01

    For a given intake mode (ingestion, inhalation, absorption through the skin), a dose conversion factor (DCF) is the committed dose equivalent to a specified organ of an individual per unit intake of a radionuclide. One also may consider the effective dose commitment per unit intake, which is a weighted average of organ-specific DCFs, with weights proportional to risks associated with stochastic radiation-induced fatal health effects, as defined by Publication 26 of the International Commission on Radiological Protection (ICRP). This report derives and tabulates organ-specific dose conversion factors and the effective dose commitment per unit intake of tritium. These factors are based on a steady-state model of hydrogen in the tissues of ICRP's Reference Man (ICRP Publication 23) and equilibrium of specific activities between body water and other tissues. The results differ by 27 to 33% from the estimate on which ICRP Publication 30 recommendations are based. The report also examines a dynamic model of tritium retention in body water, mineral bone, and two compartments representing organically-bound hydrogen. This model is compared with data from human subjects who were observed for extended periods. The manner of combining the dose conversion factors with measured or model-predicted levels of contamination in man's exposure media (air, drinking water, soil moisture) to estimate dose rate to an individual is briefly discussed.

  3. Derivation of dose conversion factors for tritium

    International Nuclear Information System (INIS)

    Killough, G.G.

    1982-03-01

    For a given intake mode (ingestion, inhalation, absorption through the skin), a dose conversion factor (DCF) is the committed dose equivalent to a specified organ of an individual per unit intake of a radionuclide. One also may consider the effective dose commitment per unit intake, which is a weighted average of organ-specific DCFs, with weights proportional to risks associated with stochastic radiation-induced fatal health effects, as defined by Publication 26 of the International Commission on Radiological Protection (ICRP). This report derives and tabulates organ-specific dose conversion factors and the effective dose commitment per unit intake of tritium. These factors are based on a steady-state model of hydrogen in the tissues of ICRP's Reference Man (ICRP Publication 23) and equilibrium of specific activities between body water and other tissues. The results differ by 27 to 33% from the estimate on which ICRP Publication 30 recommendations are based. The report also examines a dynamic model of tritium retention in body water, mineral bone, and two compartments representing organically-bound hydrogen. This model is compared with data from human subjects who were observed for extended periods. The manner of combining the dose conversion factors with measured or model-predicted levels of contamination in man's exposure media (air, drinking water, soil moisture) to estimate dose rate to an individual is briefly discussed

  4. Comparison of the two different standard flux-to-dose rate conversion factors

    International Nuclear Information System (INIS)

    Metghalchi, M.; Ashrafi, R.

    1983-01-01

    A very useful and simple way of obtaining the dose rate associated with neutron or photon fluxes is to multiply these fluxes by the appropriate flux-to-dose rate conversion factors. Two basic standard flux-to-dose rate conversion factors. are being used in all over the world, those recommended by the International Commission on Radiation Protection (ICRP) and the American National Standars (ANS). The purpose of this paper is to compare these two standard with each other. The comparison proved that the dose rate associated with a specific neutron flux, obtained by the ANS flux-to-dose rate conversion factors is usually higher than those calculated by the ICRP's conversion factors. Whereas in the case of the photon, in all energies, the difference between the dose rates obtained by these two standard flux-to-dose rate conversion factors are noticeable, and the ANS results are higher than the ICRP ones. So, it should be noted that for a specific neutron or photon flux the dose rate obtained by the ANS flux-to-dose rate conversion factors are more conservative than those obtained by the ICRP's. Therefore, in order to establish a more reasonable new standard flux-to-dose rate conversion factors, more work should be done. (author)

  5. Two-Copy Wavelength Conversion of an 80 Gbit/s Serial Data Signal Using Cross-Phase Modulation in a Silicon Nanowire and Detailed Pump-Probe Characterisation

    DEFF Research Database (Denmark)

    Ji, Hua; Cleary, C. S.; Dailey, J. M.

    2012-01-01

    We experimentally demonstrate 80 Gbit/s wavelength conversion to two copies by simultaneously extracting the blue- and red-shifted sidebands from XPM in a silicon nanowire. Bit error rates of 10-9 with only ~2 dB power penalty is achieved for both sidebands. Detailed pump-probe characterisation r...

  6. External dose conversion factor from canal water

    International Nuclear Information System (INIS)

    Bhargava, Pradeep; Chitra, S.; Mhatre, Arti S.; Singh, Kapil Deo

    2016-01-01

    External dose needs to be estimated for the radioactivity discharged into the canal, as it constitutes one of the pathways of exposure to the public. Two activities are considered here: i) a walk along the bank of the canal ii) and the walk on the bridge. A concentration of 1 Bq/l is assumed here for the gross beta activity for the estimation of the dose conversion factor. A canal of width 14.39 m and the depth of 2.5 m is considered for this study. Length of the canal is taken to be infinite. Canal side wall is assumed to be the 25 cm thick concrete. Two points are selected, one on the bank, and the second on a bridge 1 m above the top surface of canal water. Dose Conversion factors for the person moving on the Bridge (at one meter above the water surface) and standing on bank of canal is estimated by using the QAD CG code for 137 Cs. Dose conversion factors for the location mentioned above are found to be 1.11E-10 Sv/hr/(Bq/l) and 1.55 E-11 Sv/hr/(Bq/l) for bridge and bank of canal respectively. (author)

  7. Nominal Performance Biosphere Dose Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M.A. Wasiolek

    2005-04-28

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the groundwater exposure scenario, and the development of conversion factors for assessing compliance with the groundwater protection standards. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop BDCFs, which are input parameters for the TSPA-LA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the ''Biosphere Model Report'' in Figure 1-1, contain detailed description of the model input parameters, their development, and the relationship between the parameters and specific features events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the groundwater exposure scenario. This analysis receives direct input from the outputs of the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) and the five analyses that develop parameter values for the biosphere model (BSC 2005 [DIRS 172827]; BSC 2004 [DIRS 169672]; BSC 2004 [DIRS 169673]; BSC 2004 [DIRS 169458]; BSC 2004 [DIRS 169459]). The results of this report are further analyzed in the ''Biosphere Dose Conversion Factor Importance and Sensitivity Analysis

  8. Reassessment of NRC's dollar per person-rem conversion factor policy

    International Nuclear Information System (INIS)

    1995-12-01

    The US Nuclear Regulatory Commission (NRC) has completed a review and analysis of its dollar per person-rem conversion factor policy. As a result of this review, the NRC has decided to adopt a $2000 per person-rem conversion factor, subject it to present worth considerations, and limit its scope solely to health effects. This is in contrast to the previous policy and staff practice of using an undiscounted $1000 per person-rem conversion factor that served as a surrogate for all offsite consequences (health and offsite property). The policy shift has been incorporated in ''Regulatory Analysis Guidelines of the US Nuclear Regulatory Commission,'' NUREG/BR-0058, Revision 2, November 1995

  9. Conversion factors for a mobile survey method by car in the Chernobyl area

    International Nuclear Information System (INIS)

    Sakamoto, R.; Saito, K.

    2003-01-01

    Conversion factors for the purpose of mobile survey by car in the Chernobyl area have been evaluated using simulation calculations. In the calculations, the width of road is assumed as being 4 m, 10 m and 20 m and the surrounding area is divided into ten zones contaminated homogeneously by 137 Cs with different depth profiles in the ground. The air kerma contribution from all zones to the road is simulated. A conversion factor is calculated by dividing the air kerma rate in typical land-use adjacent to the road by that on the road. Conversion factors in various land uses around the roads are examined. The calculated conversion factors agree with the conversion factors measured in the Chernobyl area within an accuracy of 20%. Further, basic data, needed for composing conversion factors appropriate to other contaminated regions with different depth distributions from the Chernobyl area, are also indicated. (author)

  10. Three wavelength optical alignment of the Nova laser

    International Nuclear Information System (INIS)

    Swift, C.D.; Bliss, E.S.; Jones, W.A.; Seppala, L.G.

    1983-01-01

    The Nova laser, presently under construction at Lawrence Livermore National Laboratory, will be capable of delivering more than 100 kJ of focused energy to an Inertial Confinement Fusion (ICF) target. Operation at the fundamental wavelength of the laser (1.05 μm) and at the second and third harmonic will be possible. This paper will discuss the optical alignment systems and techniques being implemented to align the laser output to the target at these wavelengths prior to each target irradiation. When experiments require conversion of the laser light to wavelengths of 0.53 μm and 0.35 μm prior to target irradiation, this will be accomplished in harmonic conversion crystals located at the beam entrances to the target chamber. The harmonic alignment system will be capable of introducing colinear alignment beams of all three wavelengths into the laser chains at the final spatial filter. The alignment beam at 1.05 μm will be about three cm in diameter and intense enough to align the conversion crystals. Beams at 0.53 μm and 0.35 μm will be expanded by the spatial filter to full aperture (74 cm) and used to illuminate the target and other alignment aids at the target chamber focus. This harmonic illumination system will include viewing capability as well. A final alignment sensor will be located at the target chamber. It will view images of the chamber focal plane at all three wavelengths. In this way, each beam can be aligned at the desired wavelength to produce the focal pattern required for each target irradiation. The design of the major components in the harmonic alignment system will be described, and a typical alignment sequence for alignment to a target will be presented

  11. Current status on preparation of dose conversion factors based on 1990 ICRP recommendations

    International Nuclear Information System (INIS)

    Yoshizawa, Michio

    1996-01-01

    The current status of arrangement of dose conversion factors for operational quantities are explained on the basis of 1995 ICRP-ICRU recommendations. The dose conversion factors of photon, neutron and electron were recommended by ICRP Publ. 74. It's contents are described. The relation between new dose conversion factors and the laws in connection with protecting radiation are explained. The dose conversion factors of 1 cm-, 3 mm- and 70 μm - dose equivalent which were introduced into the laws connected therewith in Japan are accepted the same values of ICRP Publ. 51 for photon and neutron. I mentioned the points of discussing about new dose conversion factors which are expected to be recommended. The laws have to show the dose conversion factors to be used by calculation and estimation of radiation shield, etc. The limit of energy of ICRU individual dose equivalent for photon is now until 1 MeV, but the value is insufficient and necessary to 10 MeV as same as the ambient dose equivalent in due consideration of atomic energy facilities. JAERI is preparing these dose conversion factors now. (S.Y.)

  12. Factors associated with sputum culture conversion in patients with pulmonary tuberculosis

    Directory of Open Access Journals (Sweden)

    Greta Musteikienė

    Full Text Available Objective: The aim of this study was to determine what factors are associated with sputum culture conversion after 1 month of tuberculosis (TB treatment. Materials and methods: A total of 52 patients with new drug susceptible pulmonary TB were included in the study. Patients completed St. George respiratory questionnaire (SGRQ, they were asked about smoking, alcohol use, living conditions and education. Body mass index (BMI measurements, laboratory tests (C reactive protein [CRP], vitamin D, albumin were performed, and chest X-ray was done. After 1 month of treatment sputum culture was repeated. Results: Culture conversion after 1 month of treatment was found in 38.5% cases. None of investigated social factors appeared to have an effect on conversion, but worse overall health status (as reported in SGRQ and longer duration of tobacco smoking were detected in the “no conversion” group. Concentrations of albumin, CRP, X-ray score and the time it took Mycobacterium tuberculosis culture to grow also differed. Patients who scored 30 or more on SGRQ were more than 7 times as likely to have no conversion. However, the most important factor predicting sputum culture conversion was sputum smear grade at the beginning of treatment: patients with grade of 2+ or more had more than 20-fold higher relative risk for no conversion. Using receiver operating characteristic curve analysis, we also developed a risk score for no conversion. Conclusions: The most important factors in predicting sputum culture conversion after 1 month of treatment were grades of acid-fast bacilli in sputum smears at time of diagnosis and scores of SGRQ. Keywords: Smoking, Smear grade, St. George respiratory questionnaire, Tuberculosis, Culture conversion

  13. Nominal Performance Biosphere Dose Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M. Wasiolek

    2004-09-08

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the groundwater exposure scenario, and the development of conversion factors for assessing compliance with the groundwater protection standard. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA-LA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the ''Biosphere Model Report'' in Figure 1-1, contain detailed description of the model input parameters, their development, and the relationship between the parameters and specific features events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the groundwater exposure scenario. The objectives of this analysis are to develop BDCFs for the groundwater exposure scenario for the three climate states considered in the TSPA-LA as well as conversion factors for evaluating compliance with the groundwater protection standard. The BDCFs will be used in performance assessment for calculating all-pathway annual doses for a given concentration of radionuclides in groundwater. The conversion factors will be used for calculating gross alpha particle

  14. Nominal Performance Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    M. Wasiolek

    2004-01-01

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the Total System Performance Assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the groundwater exposure scenario, and the development of conversion factors for assessing compliance with the groundwater protection standard. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA-LA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the ''Biosphere Model Report'' in Figure 1-1, contain detailed description of the model input parameters, their development, and the relationship between the parameters and specific features events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the groundwater exposure scenario. The objectives of this analysis are to develop BDCFs for the groundwater exposure scenario for the three climate states considered in the TSPA-LA as well as conversion factors for evaluating compliance with the groundwater protection standard. The BDCFs will be used in performance assessment for calculating all-pathway annual doses for a given concentration of radionuclides in groundwater. The conversion factors will be used for calculating gross alpha particle activity in groundwater and the annual dose

  15. External dose-rate conversion factors for calculation of dose to the public

    Energy Technology Data Exchange (ETDEWEB)

    1988-07-01

    This report presents a tabulation of dose-rate conversion factors for external exposure to photons and electrons emitted by radionuclides in the environment. This report was prepared in conjunction with criteria for limiting dose equivalents to members of the public from operations of the US Department of Energy (DOE). The dose-rate conversion factors are provided for use by the DOE and its contractors in performing calculations of external dose equivalents to members of the public. The dose-rate conversion factors for external exposure to photons and electrons presented in this report are based on a methodology developed at Oak Ridge National Laboratory. However, some adjustments of the previously documented methodology have been made in obtaining the dose-rate conversion factors in this report. 42 refs., 1 fig., 4 tabs.

  16. Calculation of dose-rate conversion factors for external exposure to photons and electrons

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1978-01-01

    Methods are presented for the calculation of dose-rate conversion factors for external exposure to photon and electron radiation from radioactive decay. A dose-rate conversion factor is defined as the dose-equivalent rate per unit radionuclide concentration. Exposure modes considered are immersion in contaminated air, immersion in contaminated water, and irradiation from a contaminated ground surface. For each radiation type and exposure mode, dose-rate conversion factors are derived for tissue-equivalent material at the body surface of an exposed individual. In addition, photon dose-rate conversion factors are estimated for 22 body organs. The calculations are based on the assumption that the exposure medium is infinite in extent and that the radionuclide concentration is uniform. The dose-rate conversion factors for immersion in contaminated air and water then follow from the requirement that all of the energy emitted in the radioactive decay is absorbed in the infinite medium. Dose-rate conversion factors for ground-surface exposure are calculated at a reference location above a smooth, infinite plane using the point-kernel integration method and known specific absorbed fractions for photons and electrons in air

  17. Multi-wavelength conversion at 10 Gb/s and 40 GHZ based on nonlinear effects in HNLF

    Czech Academy of Sciences Publication Activity Database

    Karásek, Miroslav; Kaňka, Jiří; Honzátko, Pavel; Vojtěch, J.; Radil, J.

    2007-01-01

    Roč. 62, 7/8 (2007), s. 925-937 ISSN 0003-4347 R&D Projects: GA ČR GA102/05/0995; GA MŠk 1P05OC001 Institutional research plan: CEZ:AV0Z20670512 Keywords : optical communication * optical fibres * wavelength division multiplexing Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.206, year: 2007

  18. Photonic generation of FCC-compliant UWB pulses based on modified Gaussian quadruplet and incoherent wavelength-to-time conversion

    Science.gov (United States)

    Mu, Hongqian; Wang, Muguang; Tang, Yu; Zhang, Jing; Jian, Shuisheng

    2018-03-01

    A novel scheme for the generation of FCC-compliant UWB pulse is proposed based on modified Gaussian quadruplet and incoherent wavelength-to-time conversion. The modified Gaussian quadruplet is synthesized based on linear sum of a broad Gaussian pulse and two narrow Gaussian pulses with the same pulse-width and amplitude peak. Within specific parameter range, FCC-compliant UWB with spectral power efficiency of higher than 39.9% can be achieved. In order to realize the designed waveform, a UWB generator based on spectral shaping and incoherent wavelength-to-time mapping is proposed. The spectral shaper is composed of a Gaussian filter and a programmable filter. Single-mode fiber functions as both dispersion device and transmission medium. Balanced photodetection is employed to combine linearly the broad Gaussian pulse and two narrow Gaussian pulses, and at same time to suppress pulse pedestals that result in low-frequency components. The proposed UWB generator can be reconfigured for UWB doublet by operating the programmable filter as a single-band Gaussian filter. The feasibility of proposed UWB generator is demonstrated experimentally. Measured UWB pulses match well with simulation results. FCC-compliant quadruplet with 10-dB bandwidth of 6.88-GHz, fractional bandwidth of 106.8% and power efficiency of 51% is achieved.

  19. Performance of multiobjective computational intelligence algorithms for the routing and wavelength assignment problem

    Directory of Open Access Journals (Sweden)

    Jorge Patiño

    2016-01-01

    Full Text Available This paper presents an evaluation performance of computational intelligence algorithms based on the multiobjective theory for the solution of the Routing and Wavelength Assignment problem (RWA in optical networks. The study evaluates the Firefly Algorithm, the Differential Evolutionary Algorithm, the Simulated Annealing Algorithm and two versions of the Particle Swarm Optimization algorithm. The paper provides a description of the multiobjective algorithms; then, an evaluation based on the performance provided by the multiobjective algorithms versus mono-objective approaches when dealing with different traffic loads, different numberof wavelengths and wavelength conversion process over the NSFNet topology is presented. Simulation results show that monoobjective algorithms properly solve the RWA problem for low values of data traffic and low number of wavelengths. However, the multiobjective approaches adapt better to online traffic when the number of wavelengths available in the network increases as well as when wavelength conversion is implemented in the nodes.

  20. Preoperative risk factors for conversion and learning curve of minimally invasive distal pancreatectomy.

    Science.gov (United States)

    Hua, Yongfei; Javed, Ammar A; Burkhart, Richard A; Makary, Martin A; Weiss, Matthew J; Wolfgang, Christopher L; He, Jin

    2017-11-01

    Although laparoscopic distal pancreatectomy is considered a standard approach, 10% to 40% of these are converted. The preoperative risk factors for conversion are not well described. The aim of this study was to identify risk factors associated with conversion. Clinicopathological variables of 211 consecutive patients who underwent laparoscopic distal pancreatectomy between January 2007 and December 2015 at Johns Hopkins were analyzed to identify factors associated with conversion. Furthermore, the learning curve for laparoscopic distal pancreatectomy was studied. On univariate analysis of diabetes mellitus, preoperative diagnosis of malignant disease, multiorgan resection, surgeons' years and case experience were significantly associated with conversion (all P pancreatectomy with a preoperative diagnosis of malignant disease or possible multiorgan resection are at a higher risk of conversion. Surgeon experience of performing >15 procedures significantly reduces the risk of conversion. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. High-quality asynchronous heralded single-photon source at telecom wavelength

    International Nuclear Information System (INIS)

    Fasel, Sylvain; Alibart, Olivier; Tanzilli, Sebastien; Baldi, Pascal; Beveratos, Alexios; Gisin, Nicolas; Zbinden, Hugo

    2004-01-01

    We report on the experimental realization and characterization of an asynchronous heralded single-photon source based on spontaneous parametric down-conversion. Photons at 1550 nm are heralded as being inside a single-mode fibre with more than 60% probability, and the multi-photon emission probability is reduced by a factor of up to more than 500 compared to Poissonian light sources. These figures of merit, together with the choice of telecom wavelength for the heralded photons, are compatible with practical applications needing very efficient and robust single-photon sources

  2. Conversion from laparoscopic to open cholecystectomy: Multivariate analysis of preoperative risk factors

    Directory of Open Access Journals (Sweden)

    Khan M

    2005-01-01

    Full Text Available BACKGROUND: Laparoscopic cholecystectomy has become the gold standard in the treatment of symptomatic cholelithiasis. Some patients require conversion to open surgery and several preoperative variables have been identified as risk factors that are helpful in predicting the probability of conversion. However, there is a need to devise a risk-scoring system based on the identified risk factors to (a predict the risk of conversion preoperatively for selected patients, (b prepare the patient psychologically, (c arrange operating schedules accordingly, and (d minimize the procedure-related cost and help overcome financial constraints, which is a significant problem in developing countries. AIM: This study was aimed to evaluate preoperative risk factors for conversion from laparoscopic to open cholecystectomy in our setting. SETTINGS AND DESIGNS: A case control study of patients who underwent laparoscopic surgery from January 1997 to December 2001 was conducted at the Aga Khan University Hospital, Karachi, Pakistan. MATERIALS AND METHODS: All those patients who were converted to open surgery (n = 73 were enrolled as cases. Two controls who had successful laparoscopic surgery (n = 146 were matched with each case for operating surgeon and closest date of surgery. STATISTICAL ANALYSIS USED: Descriptive statistics were computed and, univariate and multivariate analysis was done through multiple logistic regression. RESULTS: The final multivariate model identified two risk factors for conversion: ultrasonographic signs of inflammation (adjusted odds ratio [aOR] = 8.5; 95% confidence interval [CI]: 3.3, 21.9 and age > 60 years (aOR = 8.1; 95% CI: 2.9, 22.2 after adjusting for physical signs, alkaline phosphatase and BMI levels. CONCLUSION: Preoperative risk factors evaluated by the present study confirm the likelihood of conversion. Recognition of these factors is important for understanding the characteristics of patients at a higher risk of conversion.

  3. VizieR Online Data Catalog: Monochromatic conversion factors to LIR & Mdust (Schreiber+, 2018)

    Science.gov (United States)

    Schreiber, C.; Elbaz, D.; Pannella, M.; Wang, T.; Ciesla, L.; Franco, M.

    2017-10-01

    These tables contain conversion factors to translate observed fluxes (Sν) or luminosities (ν*Lν) into total infrared luminosity (LIR) and dust mass (Mdust). The conversion factors are provided for the most commonly used ALMA bands (Band 3 to Band 9) and all JWST MIRI broad bands (F777W to F2550W). These factors are tabulated as a function of redshift. For each conversion factor, the tables also provide the logarithmic uncertainty on the conversion (in dex), which reflects the diversity in spectral shape. These data were calibrated on the deep Spitzer and Herschel observations of the CANDELS fields, as well as early ALMA observations. They are therefore valid for galaxies of masses close to 1010Mȯ and above. (3 data files).

  4. Frequency conversion of structured light.

    Science.gov (United States)

    Steinlechner, Fabian; Hermosa, Nathaniel; Pruneri, Valerio; Torres, Juan P

    2016-02-15

    Coherent frequency conversion of structured light, i.e. the ability to manipulate the carrier frequency of a wave front without distorting its spatial phase and intensity profile, provides the opportunity for numerous novel applications in photonic technology and fundamental science. In particular, frequency conversion of spatial modes carrying orbital angular momentum can be exploited in sub-wavelength resolution nano-optics and coherent imaging at a wavelength different from that used to illuminate an object. Moreover, coherent frequency conversion will be crucial for interfacing information stored in the high-dimensional spatial structure of single and entangled photons with various constituents of quantum networks. In this work, we demonstrate frequency conversion of structured light from the near infrared (803 nm) to the visible (527 nm). The conversion scheme is based on sum-frequency generation in a periodically poled lithium niobate crystal pumped with a 1540-nm Gaussian beam. We observe frequency-converted fields that exhibit a high degree of similarity with the input field and verify the coherence of the frequency-conversion process via mode projection measurements with a phase mask and a single-mode fiber. Our results demonstrate the suitability of exploiting the technique for applications in quantum information processing and coherent imaging.

  5. Calculation of neutron and gamma-ray flux-to-dose-rate conversion factors

    International Nuclear Information System (INIS)

    Kwon, S.G.; Lee, S.Y.; Yook, C.C.

    1981-01-01

    This paper presents flux-to-dose-rate conversion factors for neutrons and gamma rays based on the American National Standard Institute (ANSI) N666. These data are used to calculate the dose rate distribution of neutron and gamma ray in radiation fields. Neutron flux-to-dose-rate conversion factors for energies from 2.5 x 10 -8 to 20 MeV are presented; the corresponding energy range for gamma rays is 0.01 to 15 MeV. Flux-to-dose-rate conversion factors were calculated, under the assumption that radiation energy distribution has nonlinearity in the phantom, have different meaning from those values obtained by monoenergetic radiation. Especially, these values were determined with the cross section library. The flux-to-dose-rate conversion factors obtained in this work were in a good agreement to the values presented by ANSI. Those data will be useful for the radiation shielding analysis and the radiation dosimetry in the case of continuous energy distributions. (author)

  6. Photon energy conversion by near-zero permittivity nonlinear materials

    Science.gov (United States)

    Luk, Ting S.; Sinclair, Michael B.; Campione, Salvatore

    2017-12-19

    Efficient harmonic light generation can be achieved with ultrathin films by coupling an incident pump wave to an epsilon-near-zero (ENZ) mode of the thin film. As an example, efficient third harmonic generation from an indium tin oxide nanofilm (.lamda./42 thick) on a glass substrate for a pump wavelength of 1.4 .mu.m was demonstrated. A conversion efficiency of 3.3.times.10.sup.-6 was achieved by exploiting the field enhancement properties of the ENZ mode with an enhancement factor of 200. This nanoscale frequency conversion method is applicable to other plasmonic materials and reststrahlen materials in proximity of the longitudinal optical phonon frequencies.

  7. Spin-wave wavelength down-conversion at thickness steps

    Science.gov (United States)

    Stigloher, Johannes; Taniguchi, Takuya; Madami, Marco; Decker, Martin; Körner, Helmut S.; Moriyama, Takahiro; Gubbiotti, Gianluca; Ono, Teruo; Back, Christian H.

    2018-05-01

    We report a systematic experimental study on the refraction and reflection of magnetostatic spin-waves at a thickness step between two Permalloy films of different thickness. The transmitted spin-waves for the transition from a thick film to a thin film have a higher wave vector compared to the incoming waves. Consequently, such systems may find use as passive wavelength transformers in magnonic networks. We investigate the spin-wave transmission behavior by studying the influence of the external magnetic field, incident angle, and thickness ratio of the films using time-resolved scanning Kerr microscopy and micro-focused Brillouin light scattering.

  8. Nitrogen-to-Protein Conversion Factors for Three Edible Insects

    NARCIS (Netherlands)

    Janssen, Renske H.; Vincken, Jean Paul; Broek, van den Lambertus A.M.; Fogliano, Vincenzo; Lakemond, Catriona M.M.

    2017-01-01

    Insects are considered a nutritionally valuable source of alternative proteins, and their efficient protein extraction is a prerequisite for large-scale use. The protein content is usually calculated from total nitrogen using the nitrogen-to-protein conversion factor (Kp) of 6.25. This factor

  9. Gallbladder Nonvisualization in Cholecystectomy: A Factor for Conversion.

    Science.gov (United States)

    Slack, Daniel R; Grisby, Shaunda; Dike, Uzoamaka Kimberly; Kohli, Harjeet

    2018-01-01

    Many risk factors have been identified in minimally invasive cholecystectomies that lead to higher complications and conversion rates. No study that we encountered looked at nonvisualization of the gallbladder (GB) during surgery as a risk factor. We hypothesized that nonvisualization was associated with an increased risk of complications and could be an early intraoperative identifier of a higher risk procedure. Recognizing this could allow surgeons to be aware of potential risks and to be more likely to convert to open for the safety of the patient. We looked at minimally invasive cholecystectomies performed at our institution from January 2015 through April 2016 and had the performing resident fill out a survey after the surgery. Outcomes were conversion rates, intraoperative complications, and blood loss and were analyzed via Pearson χ 2 test or Mann-Whitney U test. The primary outcome showed a conversion rate of 37% in nonvisualized GBs versus 0% in visualized ( P = .001). Secondary outcomes showed significant differences in GB perforations (74% vs 13%, P = .001), omental vessel bleeding (16% vs. 0%, P = .005), and EBL (46 mL vs 29 mL, P = .001). Intraoperative nonvisualization of the GB after adequate positioning caused significantly increased risk of intraoperative complications and conversion. This knowledge could be useful during intraoperative assessment, to decide whether a case should be continued as a minimally invasive procedure or converted early to help reduce risk to the patient. Further randomized controlled studies should be performed to further demonstrate the value of this assessment.

  10. Ultrafast all-optical switching and error-free 10 Gbit/s wavelength conversion in hybrid InP-silicon on insulator nanocavities using surface quantum wells

    Energy Technology Data Exchange (ETDEWEB)

    Bazin, Alexandre; Monnier, Paul; Beaudoin, Grégoire; Sagnes, Isabelle; Raj, Rama [Laboratoire de Photonique et de Nanostructures (CNRS UPR20), Route de Nozay, Marcoussis 91460 (France); Lenglé, Kevin; Gay, Mathilde; Bramerie, Laurent [Université Européenne de Bretagne (UEB), 5 Boulevard Laënnec, 35000 Rennes (France); CNRS-Foton Laboratory (UMR 6082), Enssat, BP 80518, 22305 Lannion Cedex (France); Braive, Rémy; Raineri, Fabrice, E-mail: fabrice.raineri@lpn.cnrs.fr [Laboratoire de Photonique et de Nanostructures (CNRS UPR20), Route de Nozay, Marcoussis 91460 (France); Université Paris Diderot, Sorbonne Paris Cité, 75207 Paris Cedex 13 (France)

    2014-01-06

    Ultrafast switching with low energies is demonstrated using InP photonic crystal nanocavities embedding InGaAs surface quantum wells heterogeneously integrated to a silicon on insulator waveguide circuitry. Thanks to the engineered enhancement of surface non radiative recombination of carriers, switching time is obtained to be as fast as 10 ps. These hybrid nanostructures are shown to be capable of achieving systems level performance by demonstrating error free wavelength conversion at 10 Gbit/s with 6 mW switching powers.

  11. 76 FR 55213 - Technical Amendments to Federal Employees' Retirement System; Present Value Conversion Factors...

    Science.gov (United States)

    2011-09-07

    ... Employees' Retirement System; Present Value Conversion Factors for Spouses of Deceased Separated Employees... to read as follows: Appendix A to Subpart C of Part 843--Present Value Conversion Factors for Earlier...

  12. Broadband wavelength conversion in a silicon vertical-dual-slot waveguide

    DEFF Research Database (Denmark)

    Guo, Kai; Lin, Li; Christensen, Jesper Bjerge

    2017-01-01

    strips, and put forward a method to achieve spectrally-flattened near-zero anomalous group-velocity dispersion at telecom wavelengths. A proposed structure provides a group-velocity dispersion parameter β2 of −60 ps2/km with an e ective mode area Aeff of 0.075 µm2 at 1550 nm. This structure is predicted...

  13. Two-step frequency conversion for connecting distant quantum memories by transmission through an optical fiber

    Science.gov (United States)

    Tamura, Shuhei; Ikeda, Kohei; Okamura, Kotaro; Yoshii, Kazumichi; Hong, Feng-Lei; Horikiri, Tomoyuki; Kosaka, Hideo

    2018-06-01

    Long-distance quantum communication requires entanglement between distant quantum memories. For this purpose, photon transmission is necessary to connect the distant memories. Here, for the first time, we develop a two-step frequency conversion process (from a visible wavelength to a telecommunication wavelength and back) involving the use of independent two-frequency conversion media where the target quantum memories are nitrogen-vacancy centers in diamonds (with an emission/absorption wavelength of 637.2 nm), and experimentally characterize the performance of this process acting on light from an attenuated CW laser. A total conversion efficiency of approximately 7% is achieved. The noise generated in the frequency conversion processes is measured, and the signal-to-noise ratio is estimated for a single photon signal emitted by a nitrogen-vacancy (NV) center. The developed frequency conversion system has future applications via transmission through a long optical fiber channel at a telecommunication wavelength for a quantum repeater network.

  14. Measurements of conversion factor of the Argonauta reactor

    International Nuclear Information System (INIS)

    Souza, M.I.S.

    1988-01-01

    The conversion factor (Fc) in the Argonauta reactor using uranium target prepared by electrodeposition method, irradiated in the core and in thermal collumn with thermal neutrons flux maximum is studied. Some data obtained through γ radiation emited by U-239 are shown. (M.J.C.) [pt

  15. Monetary conversion factors for economic evaluations of substance use disorders.

    Science.gov (United States)

    McCollister, Kathryn; Yang, Xuan; Sayed, Bisma; French, Michael T; Leff, Jared A; Schackman, Bruce R

    2017-10-01

    Estimating the economic consequences of substance use disorders (SUDs) is important for evaluating existing programs and new interventions. Policy makers in particular must weigh program effectiveness with scalability and sustainability considerations in deciding which programs to fund with limited resources. This study provides a comprehensive list of monetary conversion factors for a broad range of consequences, services, and outcomes, which can be used in economic evaluations of SUD interventions (primarily in the United States), including common co-occurring conditions such as HCV and HIV. Economic measures were selected from standardized clinical assessment instruments that are used in randomized clinical trials and other research studies (e.g., quasi-experimental community-based projects) to evaluate the impact of SUD interventions. National datasets were also reviewed for additional SUD-related consequences, services, and outcomes. Monetary conversion factors were identified through a comprehensive literature review of published articles as well as targeted searches of other sources such as government reports. Eight service/consequence/outcome domains were identified containing more than sixty monetizable measures of medical and behavioral health services, laboratory services, SUD treatment, social services, productivity outcomes, disability outcomes, criminal activity and criminal justice services, and infectious diseases consequences. Unit-specific monetary conversion factors are reported, along with upper and lower bound estimates, whenever possible. Having an updated and standardized source of monetary conversion factors will facilitate and improve future economic evaluations of interventions targeting SUDs and other risky behaviors. This exercise should be repeated periodically as new sources of data become available to maintain the timeliness, comprehensiveness, and quality of these estimates. Copyright © 2017 The Authors. Published by Elsevier Inc

  16. Radon: characteristics in air and dose conversion factors

    International Nuclear Information System (INIS)

    Porstendoerfer, J.; Reineking, A.

    1998-01-01

    The dose conversion factor (DCF) which gives the relationship between effective dose and potential alpha energy concentration of inhaled short-lived radon decay products is calculated with a dosimetric approach. The calculations are based on a lung dose model with a structure that is related to the new recommended ICRP respiratory tract model (ICRP 66). The characteristics of the radon decay products concerning the unattached fraction and the activity size distribution of the radon decay products are important input quantities for the calculation of DCF. The experimental data about these quantities obtained from measurements in homes, at work places, and in the free atmosphere near ground in the last past years are reported. The DCF fraction of the unattached (DCF u ) and aerosol-attached (DCF ae ) radon decay products for different places are presented, taking into account the measured characteristics. The influence of the unattached radon daughters on the dose conversion factor DCF u is reported and compared with the DCF ae of the aerosol fraction. (author)

  17. Up to 20 Gbit/s bit-rate transparent integrated interferometric wavelength converter

    DEFF Research Database (Denmark)

    Jørgensen, Carsten; Danielsen, Søren Lykke; Hansen, Peter Bukhave

    1996-01-01

    We present a compact and optimised multiquantum-well based, integrated all-active Michelson interferometer for 26 Gbit/s optical wavelength conversion. Bit-rate transparent operation is demonstrated with a conversion penalty well below 0.5 dB at bit-rates ranging from 622 Mbit/s to 20 Gbit/s....

  18. Modeling the DBR laser used as wavelength conversion device

    DEFF Research Database (Denmark)

    Braagaard, Carsten; Mikkelsen, Benny; Durhuus, Terji

    1994-01-01

    In this paper, a novel and efficient way to model the dynamic field in optical DBR-type semiconductor devices is presented. The model accounts for the longitudinal carrier, photon, and refractive index distribution. Furthermore, the model handles both active and passive sections that may include...... gratings. Thus, simulations of components containing, e.g., gain sections, absorptive sections, phase sections, and gratings, placed arbitrarily along the longitudinal direction of the cavity, are possible. Here, the model has been used for studying the DBR laser as a wavelength converter. Particularly...

  19. Evaluation of fluence to dose equivalent conversion factors for high energy radiations, (1)

    International Nuclear Information System (INIS)

    Sato, Osamu; Uehara, Takashi; Yoshizawa, Nobuaki; Iwai, Satoshi; Tanaka, Shun-ichi.

    1992-09-01

    Computer code system and basic data have been investigated for evaluating fluence to dose equivalent conversion factors for photons and neutrons up to 10 GeV. The present work suggested that the conversion factors would be obtained by incorporating effective quality factors of charged particles into the HERMES (High Energy Radiation Monte Carlo Elaborate System) code system. The effective quality factors for charged particles were calculated on the basis of the Q-L relationships specified in the ICRP Publication-60. (author)

  20. Determination of the wavelength dependence of the differential pathlength factor from near-infrared pulse signals

    Science.gov (United States)

    Kohl, Matthias; Nolte, Christian; Heekeren, Hauke R.; Horst, Susanne; Scholz, Udo; Obrig, Hellmuth; Villringer, Arno

    1998-06-01

    For the calculation of changes in oxyhaemoglobin, deoxyhaemoglobin and the redox state of cytochrome-c-oxidase from attenuation data via a modified Beer-Lambert equation the wavelength dependence of the differential pathlength factor (DPF) has to be taken into account. The DPF, i.e. the ratio of the mean optical pathlength and the physical light source-detector separation at each wavelength, determines the crosstalk between the different concentrations and is therefore essential for a sensitive detection of chromophore changes. Here a simple method is suggested to estimate the wavelength dependence of the DPF from pulse-induced attenuation changes measured on the head of adult humans. The essence is that the DPF is the ratio of the attenuation changes over absorption coefficient changes, and that the spectral form of the pulse correlated absorption coefficient change can be assumed to be proportional to the extinction coefficient of blood. Indicators for the validity of the DPF derived for wavelengths between 700 and 970 nm are the stability of the calculated haemoglobin and cytochrome signals with variations of the wavelength range included for their calculation and its overall agreement with the data available from the literature.

  1. OMEGA: a short-wavelength laser for fusion experiments

    International Nuclear Information System (INIS)

    Soures, J.M.; Hutchison, R.J.; Jacobs, S.D.; Lund, L.D.; McCrory, R.L.; Richardson, M.C.

    1983-01-01

    The OMEGA, Nd:glass laser facility was constructed for the purpose of investigating the feasibility of direct-drive laser fusion. With 24 beams producing a total energy of 4 kJ or a peak power of 12 TW, OMEGA is capable of nearly uniform illumination of spherical targets. Six of the OMEGA beams have recently been converted to short-wavelength operation (351 nm). In this paper, we discuss details of the system design and performance, with particular emphasis on the frequency-conversion system and multi-wavelength diagnostic system

  2. A chip-scale, telecommunications-band frequency conversion interface for quantum emitters.

    Science.gov (United States)

    Agha, Imad; Ates, Serkan; Davanço, Marcelo; Srinivasan, Kartik

    2013-09-09

    We describe a chip-scale, telecommunications-band frequency conversion interface designed for low-noise operation at wavelengths desirable for common single photon emitters. Four-wave-mixing Bragg scattering in silicon nitride waveguides is used to demonstrate frequency upconversion and downconversion between the 980 nm and 1550 nm wavelength regions, with signal-to-background levels > 10 and conversion efficiency of ≈ -60 dB at low continuous wave input pump powers ( 25 % in existing geometries. Finally, we present waveguide designs that can be used to connect shorter wavelength (637 nm to 852 nm) quantum emitters with 1550 nm.

  3. Generation of 2.1 μm wavelength from degenerate high gray track ...

    Indian Academy of Sciences (India)

    2014-02-12

    Feb 12, 2014 ... to this reason an alternate way of generating 2.1 μm is presented in this paper using the well-established technology of Nd:YAG laser as pump source and widely used non-linear crystal like KTP for conversion of pump wavelength into the desired wavelength using OPO. An OPO consists of an optical cavity ...

  4. Ultralow power continuous-wave frequency conversion in hydrogenated amorphous silicon waveguides.

    Science.gov (United States)

    Wang, Ke-Yao; Foster, Amy C

    2012-04-15

    We demonstrate wavelength conversion through nonlinear parametric processes in hydrogenated amorphous silicon (a-Si:H) with maximum conversion efficiency of -13 dB at telecommunication data rates (10 GHz) using only 15 mW of pump peak power. Conversion bandwidths as large as 150 nm (20 THz) are measured in continuous-wave regime at telecommunication wavelengths. The nonlinear refractive index of the material is determined by four-wave mixing (FWM) to be n(2)=7.43×10(-13) cm(2)/W, approximately an order of magnitude larger than that of single crystal silicon. © 2012 Optical Society of America

  5. Studies on the induction of mitotic gene conversion by ultraviolet irradiation

    International Nuclear Information System (INIS)

    Ito, T.; Kobayashi, K.

    1975-01-01

    Action spectra for the induction of intragenic mitotic recombination (gene conversion) at the trp 5 locus by UV are presented for three cell stages (T 0 , T 9 and T 16 ) taken from synchronously growing cultures of Saccharomyces cerevisiae. The spectra over the range from 230 to 300 nm were taken mostly in 5-nm steps. The peak in the action spectra was significantly shifted, regardless of the stage, towards the longer wavelengths as compared with that of the absorption spectrum of DNA (258nm) or even that of thymine (265nm). In one extreme case ( 16 ), the peak was shifted 17nm from the absorption peak of DNA. Further, the spectrum changed its shape as the cell stage advanced from the non-dividing (unbudded) (T 0 ) to a dividing phase (T 16 ). Furthermore, the induction cross section decreased by a large factor (about 40), regardless of the wavelength, in going from the non-dividing to a dividing phase. From observations of the high photoreversibility of induced conversions, the major primary damage was thought to be pyrimidine dimers in the DNA

  6. Light distribution system comprising spectral conversion means

    DEFF Research Database (Denmark)

    2012-01-01

    , longer wavelength,a spectral conversion characteristics of the spectral conversion fibre being essentially determined by the spectral absorption and emission properties of the photoluminescent agent, the amount of photo- luminescent agent,and the distribution of the photoluminescent agent in the spectral......System (200, 300) for the distribution of white light, having a supply side (201, 301, 401) and a delivery side (202, 302, 402), the system being configured for guiding light with a multitude of visible wavelengths in a propagation direction P from the supply side to the distribution side...... of providing a light distribution system and a method of correcting the spectral transmission characteristics of a light distribution system are disclosed....

  7. Nonlinear frequency conversion in fiber lasers

    DEFF Research Database (Denmark)

    Svane, Ask Sebastian

    The concept of nonlinear frequency conversion entails generating light at new frequencies other than those of the source light. The emission wavelength of typical fiber laser systems, relying on rare-earth dopants, are constrained within specific bands of the infrared region. By exploiting...... nonlinear processes, light from these specific wavelength bands can be used to generate light at new frequencies otherwise not obtainable by rare-earth elements. This thesis describes work covering Raman fiber lasers (RFLs) and amplifiers for nonlinear frequency down-conversion, and also the method...... of fiberoptic Cherenkov radiation (FCR) using ultrafast pulses as a means for generating tunable visible (VIS) light at higher frequencies. Two different polarization maintaining (PM) RFL cavities are studied with an emphasis on stability and spectral broadening. The cavities are formed by inscription of fiber...

  8. Hollywood's Conversion to Color: The Technological, Economic and Aesthetic Factors.

    Science.gov (United States)

    Kindem, Forham A.

    1979-01-01

    Discusses the film industry's conversion to color cinematography in the period between the 1920s and 1960s. Cites economic considerations, technological modifications, and aesthetic preferences by audiences as factors in this development. (JMF)

  9. Risk factors for conversion from unipolar psychotic depression to bipolar disorder.

    Science.gov (United States)

    Østergaard, Søren Dinesen; Straszek, Sune; Petrides, Georgios; Skadhede, Søren; Jensen, Signe Olrik Wallenstein; Munk-Jørgensen, Povl; Nielsen, Jimmi

    2014-03-01

    Patients with unipolar psychotic depression (PD) are at high risk of developing bipolar disorder (BD). This conversion has important implications for the choice of treatment. This study, therefore, aimed to identify risk factors associated with diagnostic conversion from PD to BD. We conducted a population-based, historical prospective cohort study by merging data from Danish registers. Patients assigned an ICD-10 diagnosis of PD between 1 January 1995 and 31 December 2007 were identified in the Danish Central Psychiatric Research Register and were followed until the development of BD, death, loss to follow-up, or 31 December 2007. Potential risk factors for conversion to BD, also defined through various Danish registers, were tested in multiple logistic regression analyses with risk expressed as adjusted odds ratios (AOR). We identified 8,588 patients with PD, of whom 609 (7.1%) developed BD during follow-up. The following characteristics were significantly associated with diagnostic conversion from PD to BD: early onset of PD [AOR = 0.99 (per year of increasing age), p = 0.044], recurrent depression [AOR = 1.02 (per episode), p = 0.036], living alone (AOR = 1.29, p = 0.007), receiving a disability pension (AOR = 1.55, p conversion to BD was prevalent among patients with PD. The following characteristics were significantly associated with this conversion: early onset of PD, recurrent depression, living alone, receiving a disability pension, and the highest educational level being a technical education, short-cycle higher education, or medium-cycle higher education. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  10. Conversion of far ultraviolet to visible radiation: absolute measurements of the conversion efficiency of tetraphenyl butadiene

    Science.gov (United States)

    Vest, Robert E.; Coplan, Michael A.; Clark, Charles W.

    Far ultraviolet (FUV) scintillation of noble gases is used in dark matter and neutrino research and in neutron detection. Upon collisional excitation, noble gas atoms recombine into excimer molecules that decay by FUV emission. Direct detection of FUV is difficult. Another approach is to convert it to visible light using a wavelength-shifting medium. One such medium, tetraphenyl butadiene (TPB) can be vapor-deposited on substrates. Thus the quality of thin TPB films can be tightly controlled. We have measured the absolute efficiency of FUV-to-visible conversion by 1 μm-thick TPB films vs. FUV wavelengths between 130 and 300 nm, with 1 nm resolution. The energy efficiency of FUV to visible conversion varies between 1% and 5%. We make comparisons with other recent results. Work performed at the NIST SURF III Synchrotron Ultraviolet Radiation Facility,.

  11. Modeling of large aperture third harmonic frequency conversion of high power Nd:glass laser systems

    International Nuclear Information System (INIS)

    Henesian, M.A.; Wegner, P.J.; Speck, D.R.; Bibeau, C.; Ehrlich, R.B.; Laumann, C.W.; Lawson, J.K.; Weiland, T.L.

    1991-01-01

    To provide high-energy, high-power beams at short wavelengths for inertial-confinement-fusion experiments, we routinely convert the 1.053-μm output of the Nova, Nd:phosphate-glass, laser system to its third-harmonic wavelength. We describe performance and conversion efficiency modeling of the 3 x 3 arrays potassium-dihydrogen-phosphate crystal plates used for type II/type II phase-matched harmonic conversion of Nova 0.74-m diameter beams, and an alternate type I/type II phase-matching configuration that improves the third-harmonic conversion efficiency. These arrays provide energy conversion of up to 65% and intensity conversion to 70%. 19 refs., 11 figs

  12. Heterodyne detection of CPFSK signals with and without wavelength conversion up to 5 Gb/s

    DEFF Research Database (Denmark)

    Pedersen, Rune Johan Skullerud; Ebskamp, F.; Mikkelsen, Benny

    1993-01-01

    Detection of wavelength converted signals by a coherent continuous-phase frequency-shift-keying receiver is reported. The signals are wavelength converted over 35 nm, and record receiver sensitivities of -38.7 dBm at 4.0Gb/s and -35.6 dBm at 4.8Gb/s are obtained. Comparison between results...

  13. Laparascopic cholecystectomy for acute cholecystitis: Can preoperative factors predict conversion?

    International Nuclear Information System (INIS)

    Khan, Iftikhar A.; El-Tinay, Omer E.

    2004-01-01

    To determine if preoperative clinical, laboratory and radiology data can predict conversion of laparascopic cholecystectomy for acute cholecystitis to open procedure. Retrospective analysis of 44 laparascopic cholecystectomies were performed for acute cholecystitisbetween August 2000 and July 2002 at King Khalid University Hospital, Riyadh, kingdom of Saudi Arabia. Data related to age and sex of patients, maximum body temprature,white blood cell count, gallbladder wall thickness or ultrasonography and timing of surgery from onset of symptoms were collected.The procedure was converted from laparascopic to open cholecystectomy in 10 patients (23%). Conversion rate was significantly high (33% versus zero; p=0.01) if the gallbladder wall was thickened. Conversion rate was significantly low ( Zero versus 32%: p=0.01) if the procedure was performed within 48 hours from the onset of the symptoms. The data relawted to age, sex, white blood cell count and body temprature did not reliably predict conversion of laparascopic cholecystectomy (LD) for acute cholecystitis to open procedure. There was no mortality or major morbidity. Laparascopic cholecystectomy is a safe modality of treatment for acute cholecystitis. Factors associated with increased conversion rate are thickened gallbladder wall on ultrasonographyand delay in surgery for more than 48 hours from the onset of symptoms. (author)

  14. Influences of Pinpoint Plantar Long-Wavelength Infrared Light Irradiation (Stress-Free Therapy on Chorioretinal Hemodynamics, Atherosclerosis Factors, and Vascular Endothelial Growth Factor

    Directory of Open Access Journals (Sweden)

    Keisou Ishimaru

    2018-03-01

    Full Text Available Background: We previously reported that pinpoint plantar long-wavelength infrared light irradiation (stress-free therapy; SFT is useful for alleviating insulin resistance and improving intracranial blood flow in patients with type 2 diabetes mellitus. This study was undertaken to evaluate the influences of SFT on chorioretinal hemodynamics (retinal artery and vein blood flows as well as atherosclerosis-related factors (TG, LDL-C and VEGF in patients with dyslipidemia. Methods: Four patients with dyslipidemia received 15-minute irradiation with a stress-free apparatus (far-infrared wavelength, 30 mW. Using laser speckle flowgraphy, associations of chorioretinal blood flow with peripheral atherosclerosis-inducing factors/VEGF levels before and after irradiation were analyzed. Results: Chorioretinal blood flow increased, while TG/LDL-C levels decreased, after irradiation. VEGF tended to rise in cases with pre-irradiation baseline levels at the lower limit but tended to decrease in cases in which baseline levels had exceeded the normal range. Conclusion: SFT was suggested to enhance chorioretinal circulation and to normalize VEGF, thereby possibly contributing to amelioration of atherosclerosis-inducing factors. Abnormalities in chorioretinal hemodynamics are known to be highly involved in the pathophysiology of diabetic retinopathy and age-related macular degeneration, and anti-VEGF antibody has been used for treating these conditions. The necessity of risk management, involving chorioretinal blood flow, has been pointed out when dealing with central retinal vein occlusion, diabetes mellitus, ischemic cerebral/cardiac disease, dementia and so on. SFT is therefore a potential complementary medical strategy which can be expected to contribute to normalization of chorioretinal blood flow and atherosclerosis-inducing factors/VEGF levels, and thereby to the prevention of lifestyle-related chronic diseases. Keywords: Pinpoint plantar long-wavelength

  15. Monthly Rainfall Erosivity: Conversion Factors for Different Time Resolutions and Regional Assessments

    Directory of Open Access Journals (Sweden)

    Panos Panagos

    2016-03-01

    Full Text Available As a follow up and an advancement of the recently published Rainfall Erosivity Database at European Scale (REDES and the respective mean annual R-factor map, the monthly aspect of rainfall erosivity has been added to REDES. Rainfall erosivity is crucial to be considered at a monthly resolution, for the optimization of land management (seasonal variation of vegetation cover and agricultural support practices as well as natural hazard protection (landslides and flood prediction. We expanded REDES by 140 rainfall stations, thus covering areas where monthly R-factor values were missing (Slovakia, Poland or former data density was not satisfactory (Austria, France, and Spain. The different time resolutions (from 5 to 60 min of high temporal data require a conversion of monthly R-factor based on a pool of stations with available data at all time resolutions. Because the conversion factors show smaller monthly variability in winter (January: 1.54 than in summer (August: 2.13, applying conversion factors on a monthly basis is suggested. The estimated monthly conversion factors allow transferring the R-factor to the desired time resolution at a European scale. The June to September period contributes to 53% of the annual rainfall erosivity in Europe, with different spatial and temporal patterns depending on the region. The study also investigated the heterogeneous seasonal patterns in different regions of Europe: on average, the Northern and Central European countries exhibit the largest R-factor values in summer, while the Southern European countries do so from October to January. In almost all countries (excluding Ireland, United Kingdom and North France, the seasonal variability of rainfall erosivity is high. Very few areas (mainly located in Spain and France show the largest from February to April. The average monthly erosivity density is very large in August (1.67 and July (1.63, while very small in January and February (0.37. This study addresses

  16. Scientific Opinion on the energy conversion factor of D-tagatose for labelling purposes

    DEFF Research Database (Denmark)

    Sjödin, Anders Mikael

    2016-01-01

    Following a request from the European Commission, the EFSA Panel on Dietetic Products, Nutrition and Allergies (NDA) was asked to deliver a scientific opinion on the energy conversion factor of D-tagatose to be used for calculating the energy value of foods to be declared in nutrition labelling....... Energy conversion factors for nutrients for the purpose of nutrition labelling have been set based on the concept of metabolisable energy (ME). The same methodology has been applied to calculate the energy conversion factor for D-tagatose in this opinion. The assessment is based on a dossier prepared...... for Nutrilab NV and submitted by Bioresco Ltd. At present, data are insufficient to derive an accurate ME value for D-tagatose. Relying on the human data indicating a mean absorption rate of 80% (range 69–88%) and a urinary excretion of either 1% or 5%, the corresponding energy values for D-tagatose would be 2...

  17. Is G a conversion factor or a fundamental unit?

    OpenAIRE

    Fiorentini, G.; Okun, L.; Vysotsky, M.

    2001-01-01

    By using fundamental units c, h, G as conversion factors one can easily transform the dimensions of all observables. In particular one can make them all ``geometrical'', or dimensionless. However this has no impact on the fact that there are three fundamental units, G being one of them. Only experiment can tell us whether G is basically fundamental.

  18. Nitrogen-to-Protein Conversion Factors for Crop Residues and Animal Manure Common in China.

    Science.gov (United States)

    Chen, Xueli; Zhao, Guanglu; Zhang, Yang; Han, Lujia; Xiao, Weihua

    2017-10-25

    Accurately determining protein content is essential in exploiting biomass as feed and fuel. A survey of biomass samples in China indicated protein contents from 2.65 to 3.98% for crop residues and from 6.07 to 10.24% for animal manure of dry basis. Conversion factors based on amino acid nitrogen (k A ) ranged from 5.42 to 6.00 for the former and from 4.78 to 5.36 for the latter, indicating that the traditional factor of 6.25 is not suitable for biomass samples. On the other hand, conversion factors from Kjeldahl nitrogen (k P ) ranged from 3.97 to 4.57 and from 2.76 to 4.31 for crop residues and animal manure, respectively. Of note, conversion factors were strongly affected by amino acid composition and levels of nonprotein nitrogen. Thus, k P values of 4.23 for crop residues, 4.11 for livestock manure, and 3.11 for poultry manure are recommended to better estimate protein content from total nitrogen.

  19. Multi-channel up-conversion infrared spectrometer and method of detecting a spectral distribution of light

    DEFF Research Database (Denmark)

    2015-01-01

    A multi-channel infrared spectrometer for detecting an infrared spectrum of light received from an object. The spectrometer comprises a wavelength converter system comprising a nonlinear material and having an input side and an output side. The wavelength converter system comprises at least a first...... on the first side into light in a second output wavelength range output on the second side. The spectrometer further comprises a demultiplexer configured for demultiplexing light in the first up-conversion channel and light in the second up-conversion channel. The demultiplexer is located on the first side...

  20. Chart of conversion factors: From English to metric system and metric to English system

    Science.gov (United States)

    ,

    1976-01-01

    The conversion factors in the following tables are for conversion of our customary (English) units of measurement to SI*units, and for convenience, reciprocals are shown for converting SI units back to the English system. The first table contains rule-of-thumb figures, useful for "getting the feel" of SI units or mental estimation. The succeeding tables contain factors accurate to 3 or more significant figures. Please refer to known reference volumes for additional accuracy, as well as for factors dealing with other scientific notation involving SI units.

  1. Determination of scattering coefficient considering wavelength and absorption dependence of anisotropy factor measured by polarized beam for biological tissues

    Science.gov (United States)

    Fukutomi, D.; Ishii, K.; Awazu, K.

    2015-12-01

    Anisotropy factor g, one of the optical properties of biological tissues, is the most important parameter to accurately determine scattering coefficient μs in the inverse Monte Carlo (iMC) simulation. It has been reported that g has wavelength and absorption dependence, however, there are few attempts in order to calculate μs of biological tissue considering the wavelength and absorption dependence of g. In this study, the scattering angular distributions of biological tissue phantoms were measured in order to determine g by using goniometric measurements with three polarization conditions at strongly and weakly absorbing wavelengths of hemoglobin. Then, optical properties, especially, μs were measured by integrating sphere measurements and iMC simulation in order to confirm the influence of measured g on optical properties in comparison of with general value of g (0.9) for soft biological tissue. Consequently, it was found that μs was overestimated at strongly absorbing wavelength, however, μs was underestimated at weakly absorbing wavelength if the g was not considered its wavelength and absorption dependence.

  2. Recent advances in long wavelength quantum dot lasers and amplifiers

    NARCIS (Netherlands)

    Nötzel, R.; Bente, E.A.J.M.; Smit, M.K.; Dorren, H.J.S.

    2009-01-01

    We demonstrate 1.55-µm InAs/InGaAsP/InP (100) quantum dot (QD) shallow and deep etched Fabry-Pérot and ring lasers, micro-ring lasers, mode-locked lasers, Butt-joint integrated lasers, polarization control of gain, and wavelength conversion in QD amplifiers.

  3. Determination of the scattering coefficient of biological tissue considering the wavelength and absorption dependence of the anisotropy factor

    Science.gov (United States)

    Fukutomi, Daichi; Ishii, Katsunori; Awazu, Kunio

    2016-04-01

    The anisotropy factor g, one of the optical properties of biological tissues, has a strong influence on the calculation of the scattering coefficient μ s in inverse Monte Carlo (iMC) simulations. It has been reported that g has the wavelength and absorption dependence; however, few attempts have been made to calculate μ s using g values by taking the wavelength and absorption dependence into account. In this study, the angular distributions of scattered light for biological tissue phantoms containing hemoglobin as a light absorber were measured by a goniometric optical setup at strongly (405 nm) and weakly (664 nm) absorbing wavelengths to obtain g. Subsequently, the optical properties were calculated with the measured values of g by integrating sphere measurements and an iMC simulation, and compared with the results obtained with a conventional g value of 0.9. The μ s values with measured g were overestimated at the strongly absorbing wavelength, but underestimated at the weakly absorbing wavelength if 0.9 was used in the iMC simulation.

  4. Mode conversion in magneto photonic crystal fibre

    International Nuclear Information System (INIS)

    Otmani, Hamza; Bouchemat, Mohamed; Hocini, Abdesselam; Boumaza, Touraya; Benmerkhi, Ahlem

    2017-01-01

    The first concept of an integrated isolator was based on nonreciprocal TE–TM mode conversion, the nonreciprocal coupling between these modes is caused by the Faraday rotation if the magnetization is aligned along the z–axis, parallel to mode propagation. We propose to study this magneto-optical phenomenon, by the simulation of magneto photonic crystal fibre (MPCF), it consists of a periodic triangular lattice of air-holes filled with magnetic fluid which consists of magnetic nanoparticles into a BIG (Bismuth Iron Garnet) fibre. We simulated the influence of gyrotropy and the wavelength, and calculated Faraday rotation and modal birefringence. In this fibre the light is guided by internal total reflection, like classical fibres. However it was shown that they could function on a mode conversion much stronger than conventional fibres. - Highlights: • We propose to study mode conversion TE–TM, by the simulation of magneto photonic crystal fibre (MPCF). • We simulated the influence of gyrotropy. • We simulated the wavelength. • We calculated Faraday rotation. • We calculated modal birefringence.

  5. Landscape dose conversion factors used in the safety assessment SR-Site

    International Nuclear Information System (INIS)

    Avila, Rodolfo; Ekstroem, Per-Anders; Aastrand, Per-Gustav

    2010-12-01

    In this report two types of Dose Conversion Factors have been derived: i) a Landscape Dose Conversion Factor (LDF) that is applicable to continuous long-term releases to the biosphere at a constant rate, and ii) a Landscape Dose Conversion Factor for pulse releases (LDF pulse) that is applicable to a radionuclide release that reaches the biosphere in a pulse within years to hundreds of years. In SR-Site these Dose Factors are multiplied with modelled release rates or pulse releases from the geosphere to obtain dose estimates used in assessment of compliance with the regulatory risk criterion. The LDFs were calculated for three different periods of the reference glacial cycle; a period of submerged conditions following the deglaciation, the temperate period, and a prolonged period of periglacial conditions. Additionally, LDFs were calculated for the global warming climate case. The LDF pulse was calculated only for temperate climate conditions. The LDF and LDF pulse can be considered as Best Estimate values, which can be used in calculations of Best Estimate values of doses to a representative individual of the most exposed group from potential releases from a future repository. A systematic analysis of the effects of system, model and parameter uncertainties on the LDFs has been carried out. This analysis has shown that the use of the derived LDF would lead to cautious or realistic dose estimates. The models and methods that were used for derivation of the LDFs and LDF pulse are also described in this report

  6. Landscape dose conversion factors used in the safety assessment SR-Site

    Energy Technology Data Exchange (ETDEWEB)

    Avila, Rodolfo; Ekstroem, Per-Anders; Aastrand, Per-Gustav (Facilia AB (Sweden))

    2010-12-15

    In this report two types of Dose Conversion Factors have been derived: i) a Landscape Dose Conversion Factor (LDF) that is applicable to continuous long-term releases to the biosphere at a constant rate, and ii) a Landscape Dose Conversion Factor for pulse releases (LDF pulse) that is applicable to a radionuclide release that reaches the biosphere in a pulse within years to hundreds of years. In SR-Site these Dose Factors are multiplied with modelled release rates or pulse releases from the geosphere to obtain dose estimates used in assessment of compliance with the regulatory risk criterion. The LDFs were calculated for three different periods of the reference glacial cycle; a period of submerged conditions following the deglaciation, the temperate period, and a prolonged period of periglacial conditions. Additionally, LDFs were calculated for the global warming climate case. The LDF pulse was calculated only for temperate climate conditions. The LDF and LDF pulse can be considered as Best Estimate values, which can be used in calculations of Best Estimate values of doses to a representative individual of the most exposed group from potential releases from a future repository. A systematic analysis of the effects of system, model and parameter uncertainties on the LDFs has been carried out. This analysis has shown that the use of the derived LDF would lead to cautious or realistic dose estimates. The models and methods that were used for derivation of the LDFs and LDF pulse are also described in this report

  7. Direct measurement of electron beam quality conversion factors using water calorimetry.

    Science.gov (United States)

    Renaud, James; Sarfehnia, Arman; Marchant, Kristin; McEwen, Malcolm; Ross, Carl; Seuntjens, Jan

    2015-11-01

    In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9-20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%-0.40%) and its influence on the perturbation correction (Type B, 0.10%-0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, kecal, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM's TG-51 protocol. General agreement between the relative

  8. Development of suspended core soft glass fibers for far-detuned parametric conversion

    Science.gov (United States)

    Rampur, Anupamaa; Ciąćka, Piotr; Cimek, Jarosław; Kasztelanic, Rafał; Buczyński, Ryszard; Klimczak, Mariusz

    2018-04-01

    Light sources utilizing χ (2) parametric conversion combine high brightness with attractive operation wavelengths in the near and mid-infrared. In optical fibers, it is possible to use χ (3) degenerate four-wave mixing in order to obtain signal-to-idler frequency detuning of over 100 THz. We report on a test series of nonlinear soft glass suspended core fibers intended for parametric conversion of 1000-1100 nm signal wavelengths available from an array of mature lasers into the near-to-mid-infrared range of 2700-3500 nm under pumping with an erbium sub-picosecond laser system. The presented discussion includes modelling of the fiber properties, details of their physical development and characterization, and experimental tests of parametric conversion.

  9. General equation for the differential pathlength factor of the frontal human head depending on wavelength and age.

    Science.gov (United States)

    Scholkmann, Felix; Wolf, Martin

    2013-10-01

    Continuous-wave near-infrared spectroscopy and near-infrared imaging enable the measurement of relative concentration changes in oxy- and deoxyhemoglobin and thus hemodynamics and oxygenation. The accuracy of determined changes depends mainly on the modeling of the light transport through the probed tissue. Due to the highly scattering nature of tissue, the light path is longer than the source-detector separation (d). This is incorporated in modeling by multiplying d by a differential pathlength factor (DPF) which depends on several factors such as wavelength, age of the subject, and type of tissue. In the present work, we derive a general DPF equation for the frontal human head, incorporating dependency on wavelength and age, based on published data. We validated the equation using different data sets of experimentally determined DPFs from six independent studies.

  10. Perforated Peptic Ulcer Repair: Factors Predicting Conversion in Laparoscopy and Postoperative Septic Complications.

    Science.gov (United States)

    Muller, Markus K; Wrann, Simon; Widmer, Jeannette; Klasen, Jennifer; Weber, Markus; Hahnloser, Dieter

    2016-09-01

    The surgical treatment for perforated peptic ulcers can be safely performed laparoscopically. The aim of the study was to define simple predictive factors for conversion and septic complications. This retrospective case-control study analyzed patients treated with either laparoscopic surgery or laparotomy for perforated peptic ulcers. A total of 71 patients were analyzed. Laparoscopically operated patients had a shorter hospital stay (13.7 vs. 15.1 days). In an intention-to-treat analysis, patients with conversion to open surgery (analyzed as subgroup from laparoscopic approach group) showed no prolonged hospital stay (15.3 days) compared to patients with a primary open approach. Complication and mortality rates were not different between the groups. The statistical analysis identified four intraoperative risk factors for conversion: Mannheim peritonitis index (MPI) > 21 (p = 0.02), generalized peritonitis (p = 0.04), adhesions, and perforations located in a region other than the duodenal anterior wall. We found seven predictive factors for septic complications: age >70 (p = 0.02), cardiopulmonary disease (p = 0.04), ASA > 3 (p = 0.002), CRP > 100 (p = 0.005), duration of symptoms >24 h (p = 0.02), MPI > 21(p = 0.008), and generalized peritonitis (p = 0.02). Our data suggest that a primary laparoscopic approach has no disadvantages. Factors necessitating conversions emerged during the procedure inhibiting a preoperative selection. Factors suggesting imminent septic complications can be assessed preoperatively. An assessment of the proposed parameters may help optimize the management of possible septic complications.

  11. Effect of Previous Abdominal Surgery on Laparoscopic Liver Resection: Analysis of Feasibility and Risk Factors for Conversion.

    Science.gov (United States)

    Cipriani, Federica; Ratti, Francesca; Fiorentini, Guido; Catena, Marco; Paganelli, Michele; Aldrighetti, Luca

    2018-03-28

    Previous abdominal surgery has traditionally been considered an additional element of difficulty to later laparoscopic procedures. The aim of the study is to analyze the effect of previous surgery on the feasibility and safety of laparoscopic liver resection (LLR), and its role as a risk factor for conversion. After matching, 349 LLR in patients known for previous abdominal surgery (PS group) were compared with 349 LLR on patients with a virgin abdomen (NPS group). Subgroup analysis included 161 patients with previous upper abdominal surgery (UPS subgroup). Feasibility and safety were evaluated in terms of conversion rate, reasons for conversion and outcomes, and risk factors for conversion assessed via uni/multivariable analysis. Conversion rate was 9.4%, and higher for PS patients compared with NPS patients (13.7% versus 5.1%, P = .021). Difficult adhesiolysis resulted the commonest reason for conversion in PS group (5.7%). However, operative time (P = .840), blood loss (P = .270), transfusion (P = .650), morbidity rate (P = .578), hospital stay (P = .780), and R1 rate (P = .130) were comparable between PS and NPS group. Subgroup analysis confirmed higher conversion rates for UPS patients (23%) compared with both NPS (P = .015) and PS patients (P = .041). Previous surgery emerged as independent risk factor for conversion (P = .033), alongside the postero-superior location and major hepatectomy. LLR are feasible in case of previous surgery and proved to be safe and maintain the benefits of LLR carried out in standard settings. However, a history of surgery should be considered a risk factor for conversion.

  12. Characterization and optimization of a high-efficiency AlGaAs-On-Insulator-based wavelength converter for 64- and 256-QAM signals

    DEFF Research Database (Denmark)

    Da Ros, Francesco; Yankov, Metodi Plamenov; Porto da Silva, Edson

    2017-01-01

    of the wavelength converter is reported, including the optimization of the AlGaAsOI nano-waveguide in terms of conversion efficiency and associated bandwidth and the analysis of the impact of the converter pump quality and power as well as the signal input power. The optimized converter enables generating idlers......In this paper, we demonstrate wavelength conversion of advanced modulation formats such as 10-GBd 64-QAM and 256-QAM with high conversion efficiency over a 29-nm spectral window by using four-wave mixing in an AlGaAs-On-Insulator (AlGaAsOI) nano-waveguide. A thorough characterization...

  13. Method of stabilizing a laser apparatus with wavelength converter

    DEFF Research Database (Denmark)

    2013-01-01

    and to output the frequency-converted radiation (213), the frequency-converted radiation having at least a second wavelength different from the first wavelength, the diode laser (10) comprising at least a first and a second section (222,223), a first contact (220) for injecting a first current (I1......) into the first section (222), a second contact (221) for injecting a second current (I2) into the second section (223), and means for controlling a temperature of the diode laser; wherein the method comprises monitoring a first parameter indicative of the power content of a dominant lobe of the first radiation......A method of controlling beam quality and stability of a laser apparatus, the laser apparatus comprising, a diode laser (10) providing first radiation of at least a first wavelength, and a frequency conversion unit (12) configured to frequency-convert the first radiation from the diode laser...

  14. Multi-wavelength copper vapour lasers for novel materials processing application

    International Nuclear Information System (INIS)

    Knowles, M.; Foster-Turner, R.; Kearsley, A.; Evans, J.

    1995-01-01

    The copper vapour laser (CVL) is a high average power, short pulse laser with a multi-kilohertz pulse repetition rate. The CVL laser lines (511 nm and 578 nm) combined with the good beam quality and high peak power available from these lasers allow it to operate in a unique parameter space. Consequently, it has demonstrated many unique and advantageous machining characteristics. We have also demonstrated efficient conversion of CVL radiation to other wavelengths using non-linear frequency conversion, dye lasers and Ti:AL 2 O 3 . Output powers of up to 4 W at 255 nm have been achieved by frequency doubling. The frequency doubled CVL is inherently narrow linewidth and frequency locked making it a suitable source for UV photolithography. Slope efficiencies in excess of 25 % have been achieved with CVL pumped Ti:Al 2 O 3 and dye lasers. These laser extend the wavelengths options into the red and infrared regions of the spectrum. The near diffraction limited beams from these tunable lasers can be efficiently frequency doubled into the blue and near UV. The wide range of wavelength options from the CVL enable a wide variety of materials processing and material interactions to be explored. A European consortium for Copper Laser Applications in Manufacture and Production (CLAMP) has been set up under the EUREKA scheme to coordinate the commercial and technical expertise currently available in Europe. (author)

  15. Direct measurement of electron beam quality conversion factors using water calorimetry

    Energy Technology Data Exchange (ETDEWEB)

    Renaud, James, E-mail: james.renaud@mail.mcgill.ca; Seuntjens, Jan [Medical Physics Unit, McGill University, Montréal, Québec H3G 1A4 (Canada); Sarfehnia, Arman [Medical Physics Unit, McGill University, Montréal, Québec H3G 1A4, Canada and Department of Radiation Oncology, University of Toronto, Toronto, Ontario M5S 3E2 (Canada); Marchant, Kristin [Allan Blair Cancer Centre, Saskatchewan Cancer Agency, Regina, Saskatchewan S4T 7T1, Canada and Department of Oncology, University of Saskatchewan, Saskatoon, Saskatchewan S7N 5A1 (Canada); McEwen, Malcolm; Ross, Carl [Ionizing Radiation Standards, National Research Council of Canada, Ottawa, Ontario K1A 0R6 (Canada)

    2015-11-15

    Purpose: In this work, the authors describe an electron sealed water calorimeter (ESWcal) designed to directly measure absorbed dose to water in clinical electron beams and its use to derive electron beam quality conversion factors for two ionization chamber types. Methods: A functioning calorimeter prototype was constructed in-house and used to obtain reproducible measurements in clinical accelerator-based 6, 9, 12, 16, and 20 MeV electron beams. Corrections for the radiation field perturbation due to the presence of the glass calorimeter vessel were calculated using Monte Carlo (MC) simulations. The conductive heat transfer due to dose gradients and nonwater materials was also accounted for using a commercial finite element method software package. Results: The relative combined standard uncertainty on the ESWcal dose was estimated to be 0.50% for the 9–20 MeV beams and 1.00% for the 6 MeV beam, demonstrating that the development of a water calorimeter-based standard for electron beams over such a wide range of clinically relevant energies is feasible. The largest contributor to the uncertainty was the positioning (Type A, 0.10%–0.40%) and its influence on the perturbation correction (Type B, 0.10%–0.60%). As a preliminary validation, measurements performed with the ESWcal in a 6 MV photon beam were directly compared to results derived from the National Research Council of Canada (NRC) photon beam standard water calorimeter. These two independent devices were shown to agree well within the 0.43% combined relative uncertainty of the ESWcal for this beam type and quality. Absorbed dose electron beam quality conversion factors were measured using the ESWcal for the Exradin A12 and PTW Roos ionization chambers. The photon-electron conversion factor, k{sub ecal}, for the A12 was also experimentally determined. Nonstatistically significant differences of up to 0.7% were found when compared to the calculation-based factors listed in the AAPM’s TG-51 protocol

  16. Y{sub 2}O{sub 3}: Eu{sup 3+}, Tb{sup 3+} spherical particles based anti-reflection and wavelength conversion bi-functional films: Synthesis and application to solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Miao, Hui [School of Physics, Northwest University, Xi’an 710069 (China); National Photoelectric Technology and Functional Materials & Application of Science and Technology International Cooperation Base, Northwest University, Xi’an 710069 (China); Ji, Ruonan [School of Physics, Northwest University, Xi’an 710069 (China); Hu, Xiaoyun, E-mail: hxy3275@nwu.edu.cn [School of Physics, Northwest University, Xi’an 710069 (China); National Photoelectric Technology and Functional Materials & Application of Science and Technology International Cooperation Base, Northwest University, Xi’an 710069 (China); Han, Linzi; Hao, Yuanyuan; Sun, Qian [School of Physics, Northwest University, Xi’an 710069 (China); Zhang, Dekai [School of Physics, Northwest University, Xi’an 710069 (China); National Photoelectric Technology and Functional Materials & Application of Science and Technology International Cooperation Base, Northwest University, Xi’an 710069 (China); Fan, Jun [School of Chemical Engineering, Northwest University, Xi’an 710069 (China); Bai, Jintao [School of Physics, Northwest University, Xi’an 710069 (China); National Photoelectric Technology and Functional Materials & Application of Science and Technology International Cooperation Base, Northwest University, Xi’an 710069 (China); and others

    2015-04-25

    Highlights: • Eu{sup 3+} and Tb{sup 3+} co-doped Y{sub 2}O{sub 3} particles were successfully prepared. The as prepared particles can convert UV region photos to visible photons between 460 nm and 640 nm, which just matched the spectral response of most solar cells. • Y{sub 2}O{sub 3} is not only a good photoluminescence host material, but also it has high corrosion resistivity, thermal stability, and transparency from violet to infrared light. Cooperated with SiO{sub 2} sols, it could realize a better anti-reflection property. • As a proof-of-concept application, the as prepared bi-functional films could effectively improve the photoelectric conversion efficiency by 0.23% compared to pure SiO{sub 2} AR coating film and 0.55% compared to glass. - Abstract: In this study, Eu{sup 3+} and Tb{sup 3+} co-doped Y{sub 2}O{sub 3} particles were prepared via the simple, cost-effective urea homogeneous precipitation method without additives. The chosen particles were added in the SiO{sub 2} sols to get anti-reflection (AR) and wavelength conversion bi-functional films. Careful investigations were carried out to find the optimum preparation conditions and proper morphology. SEM images showed that the particle sizes reduced as metal ion/urea ratio decreased. Additionally, the extracted particles turned from sphere to lamellar type when the deionized water, which was used as solvent, reduced to a certain extent. The mechanisms of the morphology formation and diversification were proposed as well. The as prepared materials can convert UV region photos to visible photons between 460 nm and 640 nm, which just matched the spectral response of most solar cells. The spherical sample showed better luminescence performance than the one with lamellar morphology. In addition, the optical transmittance spectra indicated that the films adding spherical particles had better anti-reflective performance, and the best adding amount was 0.08 g. Finally, As a proof-of-concept application

  17. Dual-wavelength phase-shifting digital holography selectively extracting wavelength information from wavelength-multiplexed holograms.

    Science.gov (United States)

    Tahara, Tatsuki; Mori, Ryota; Kikunaga, Shuhei; Arai, Yasuhiko; Takaki, Yasuhiro

    2015-06-15

    Dual-wavelength phase-shifting digital holography that selectively extracts wavelength information from five wavelength-multiplexed holograms is presented. Specific phase shifts for respective wavelengths are introduced to remove the crosstalk components and extract only the object wave at the desired wavelength from the holograms. Object waves in multiple wavelengths are selectively extracted by utilizing 2π ambiguity and the subtraction procedures based on phase-shifting interferometry. Numerical results show the validity of the proposed technique. The proposed technique is also experimentally demonstrated.

  18. Design, demonstration and analysis of a modified wavelength-correlating receiver for incoherent OCDMA system.

    Science.gov (United States)

    Zhou, Heng; Qiu, Kun; Wang, Leyang

    2011-03-28

    A novel wavelength-correlating receiver for incoherent Optical Code Division Multiple Access (OCDMA) system is proposed and demonstrated in this paper. Enabled by the wavelength conversion based scheme, the proposed receiver can support various code types including one-dimensional optical codes and time-spreading/wavelength-hopping two dimensional codes. Also, a synchronous detection scheme with time-to- wavelength based code acquisition is proposed, by which code acquisition time can be substantially reduced. Moreover, a novel data-validation methodology based on all-optical pulse-width monitoring is introduced for the wavelength-correlating receiver. Experimental demonstration of the new proposed receiver is presented and low bit error rate data-receiving is achieved without optical hard limiting and electronic power thresholding. For the first time, a detailed theoretical performance analysis specialized for the wavelength-correlating receiver is presented. Numerical results show that the overall performance of the proposed receiver prevails over conventional OCDMA receivers.

  19. VizieR Online Data Catalog: Flux conversion factors for the Swift/UVOT filters (Brown+, 2016)

    Science.gov (United States)

    Brown, P. J.; Breeveld, A.; Roming, P. W. A.; Siegel, M.

    2016-10-01

    The conversion of observed magnitudes (or the actual observed photon or electron count rates) to a flux density is one of the most fundamental calculations. The flux conversions factors for the six Swift/UVOT filters are tabulated in Table1. (1 data file).

  20. Multi-client quantum key distribution using wavelength division multiplexing

    International Nuclear Information System (INIS)

    Grice, Warren P.; Bennink, Ryan S.; Earl, Dennis Duncan; Evans, Philip G.; Humble, Travis S.; Pooser, Raphael C.; Schaake, Jason; Williams, Brian P.

    2011-01-01

    Quantum Key Distribution (QKD) exploits the rules of quantum mechanics to generate and securely distribute a random sequence of bits to two spatially separated clients. Typically a QKD system can support only a single pair of clients at a time, and so a separate quantum link is required for every pair of users. We overcome this limitation with the design and characterization of a multi-client entangled-photon QKD system with the capacity for up to 100 clients simultaneously. The time-bin entangled QKD system includes a broadband down-conversion source with two unique features that enable the multi-user capability. First, the photons are emitted across a very large portion of the telecom spectrum. Second, and more importantly, the photons are strongly correlated in their energy degree of freedom. Using standard wavelength division multiplexing (WDM) hardware, the photons can be routed to different parties on a quantum communication network, while the strong spectral correlations ensure that each client is linked only to the client receiving the conjugate wavelength. In this way, a single down-conversion source can support dozens of channels simultaneously--and to the extent that the WDM hardware can send different spectral channels to different clients, the system can support multiple client pairings. We will describe the design and characterization of the down-conversion source, as well as the client stations, which must be tunable across the emission spectrum.

  1. Methane conversion factors from cattle manure in Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Avalos, E E:mail: egavalos@imp.mx [Instituto Mexicano del Petroleo, Mexico, D.F. (Mexico); Ruiz-Suarez, L G [Centro de Ciencias de la Atmosfera, Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2007-01-15

    Methane emission factors from different cattle manure management systems including simulated slurry system fermentation were experimentally determined in this and a previous study (Gonzalez-Avalos and Ruiz-Suarez, 2001). Combining results from both studies, we report values for maximum CH4 yield, called B0, for manure produced by cattle under different production systems and climates, which also implies different quality of feeds and associated methane conversion factors (MCF) for distinct manure management systems. This set of data has the same functionality than that of the current IPCC methodology, but offer a wider set of key parameters to estimate methane emissions from manure, which may be of interest in other countries. In this work, we report MCF can be up to 17.3 times smaller than those suggested in the 1996 Revised IPCC Methodology Guidelines (IPCC, 1997) and Good Practice Guidance (IPCC, 2000). [Spanish] Los factores de emision de metano de diferentes sistemas de manejo de excretas, incluyendo la simulacion de la fermentacion en un sistema de lechada, fueron determinados experimentalmente en este trabajo y en otro anterior (Gonzalez-Avalos y Ruiz-Suarez, 2001). Al combinar ambos, se obtuvieron valores para la produccion maxima de metano (B0) provenientes de excretas producidas por ganado bovino de diferentes sistemas de produccion y climas, lo cual implica diversas calidades de alimento y factores de conversion de metano (MCF) dependiendo de los sistemas de manejo de excretas. Este conjunto de datos tiene la misma funcionalidad que los de la metodologia actual del IPCC, pero ofrece un conjunto de parametros mas amplio para estimar las emisiones de metano por excretas, lo cual puede ser de interes en otros paises. En este trabajo se reporta que los MCF pueden ser hasta 17.3 veces mas pequenos que los sugeridos en las Directrices de la Metodologia Revisada del IPCC de 1996 (IPCC, 1997) y en la Guia de Buenas Practicas (IPCC, 2000).

  2. 12 CFR 615.5212 - Credit conversion factors-off-balance sheet items.

    Science.gov (United States)

    2010-01-01

    ...). The resultant credit equivalent amount is assigned to the appropriate risk-weight category described... directly or indirectly retains or assumes credit risk. For risk participations in such arrangements... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Credit conversion factors-off-balance sheet...

  3. Experimental determination of relative light conversion factors of TLD-100 for protons with energies from 2.0 to 9.0 MeV

    International Nuclear Information System (INIS)

    Schmidt, P.; Fellinger, J.; Henniger, J.; Huebner, K.

    1988-01-01

    The efficiency of thermoluminescent (TL) detectors to heavy charged particles is described by the so-called light conversion factor η. Relative light conversion factors for protons, alphas and heavier recoils are needed for the calculation of the neutron sensitivity of TL detectors. Such light conversion factors can be determined experimentally. In this paper a method is presented for the experimental determination of relative light conversion factors. Using the experimental arrangement described, relative light conversion factors for LiF material (TLD-100) for protons were determined. In LiF the relative main peak (peak V) efficiency is always lower than 1. It increases with increasing proton energy whereas the relative efficiency of the high temperature peak (peak VI) shows an opposite dependence on the proton energy. Relative light conversion factors for peak VI clearly exceed 1. (orig.)

  4. Dose conversion factors for inhalation applicable to the mining and milling of radioactive ores

    International Nuclear Information System (INIS)

    Hartley, B.M.

    1992-01-01

    The ICRP recommended revised dose limits for exposure to ionising radiation in November 1990. As well as reducing the annual occupational dose equivalent limit to an average of 20 mSv over 5 years, modified organ weighting factors were recommended, reflecting improved understanding of cancer risk factors for tissues and organs. The adjustment of weighting factors means that derived air concentrations conversion factors and annual limits on intake for exposure to airborne radionuclides are not simply modified by the ratio of the old to the new limits. A recalculation of these factors for radionuclides of interest in the mining and milling of radioactive ores is presented. A computer program for this purpose, based on the ICRP 30 inhalation model, is described. Rapid calculations of dose conversion factors are possible for the naturally occurring radionuclides in the 235 U, 238 U and 232 Th decay chains for which data are given in the supplements to ICRP 30. 7 refs., 12 tabs., 5 figs

  5. Conversion factors for the ICRU dose equivalent quantities for calibrating radiation dosemeters

    International Nuclear Information System (INIS)

    Grosswendt, B.; Hohlfeld, K.; Kramer, H.M.; Selbach, H.J.

    1985-02-01

    Report describing the application of conversion factors for monoenergetic photon radiation and for X and gamma reference radiation used for dosemeter calibration with the aid of spherical or rectangular phantoms (environmental and individual monitoring). (DG) [de

  6. Efficient soft x-ray generation in short wavelength laser produced plasmas

    International Nuclear Information System (INIS)

    Mochizuki, T.; Yamanaka, C.

    1987-01-01

    Intense x-ray generation in 1.053, 0.53, 0.26 μm laser-produced plasma has been investigated in the photon energy range of 0.1 to 3keV. The x-ray spectrum is found to have several humps which move to the higher energy side as the atomic number of the target increases. This atomic dependence is explained by a semi-Moseley's law and allows us to predict a target material most suitable for generating the photons of desired energies. Conversion efficiencies of 1.5 -- 3keV x-rays are obtained also as a function of laser wavelength at the intensity of 10/sup 13/W/cm/sup 2/. The conversion efficiency of keV x rays has been enhanced by a factor of 2 -- 3 with a controlled prepulse laser. From the semi-Moseley's law we find that cryogenic targets using either Xe or Kr in a liquid or solid phase may be most useful for a number of applications because they radiate 1 -- 3 keV x rays efficiently and never deposit on the x-ray optical components and the objects to be exposed

  7. Material-specific Conversion Factors for Different Solid Phantoms Used in the Dosimetry of Different Brachytherapy Sources

    Directory of Open Access Journals (Sweden)

    Sedigheh Sina

    2015-07-01

    Full Text Available Introduction Based on Task Group No. 43 (TG-43U1 recommendations, water phantom is proposed as a reference phantom for the dosimetry of brachytherapy sources. The experimental determination of TG-43 parameters is usually performed in water-equivalent solid phantoms. The purpose of this study was to determine the conversion factors for equalizing solid phantoms to water. Materials and Methods TG-43 parameters of low- and high-energy brachytherapy sources (i.e., Pd-103, I-125 and Cs-137 were obtained in different phantoms, using Monte Carlo simulations. The brachytherapy sources were simulated at the center of different phantoms including water, solid water, poly(methyl methacrylate, polystyrene and polyethylene. Dosimetric parameters such as dose rate constant, radial dose function and anisotropy function of each source were compared in different phantoms. Then, conversion factors were obtained to make phantom parameters equivalent to those of water. Results Polynomial coefficients of conversion factors were obtained for all sources to quantitatively compare g(r values in different phantom materials and the radial dose function in water. Conclusion Polynomial coefficients of conversion factors were obtained for all sources to quantitatively compare g(r values in different phantom materials and the radial dose function in water.

  8. Spectrally-isolated violet to blue wavelength generation by cascaded degenerate four-wave mixing in a photonic crystal fiber.

    Science.gov (United States)

    Yuan, Jinhui; Kang, Zhe; Li, Feng; Zhang, Xianting; Zhou, Guiyao; Sang, Xinzhu; Wu, Qiang; Yan, Binbin; Zhou, Xian; Wang, Liang; Zhong, Kangping; Wang, Kuiru; Yu, Chongxiu; Tam, Hwa Yaw; Wai, P K A

    2016-06-01

    Generation of spectrally-isolated wavelengths in the violet to blue region based on cascaded degenerate four-wave mixing (FWM) is experimentally demonstrated for the first time in a tailor-made photonic crystal fiber, which has two adjacent zero dispersion wavelengths (ZDWs) at 696 and 852 nm in the fundamental mode. The influences of the wavelength λp and the input average power Pav of the femtosecond pump pulses on the phase-matched frequency conversion process are studied. When femtosecond pump pulses at λp of 880, 870, and 860 nm and Pav of 500 mW are coupled into the normal dispersion region close to the second ZDW, the first anti-Stokes waves generated near the first ZDW act as a secondary pump for the next FWM process. The conversion efficiency ηas2 of the second anti-Stokes waves, which are generated at the violet to blue wavelengths of 430, 456, and 472 nm, are 4.8, 6.48, and 9.66%, for λp equalling 880, 870, and 860 nm, respectively.

  9. Towards spontaneous parametric down-conversion at low temperatures

    Directory of Open Access Journals (Sweden)

    Akatiev Dmitrii

    2017-01-01

    Full Text Available The possibility of observing spontaneous parametric down-conversion in doped nonlinear crystals at low temperatures, which would be useful for combining heralded single-photon sources and quantum memories, is studied theoretically. The ordinary refractive index of a lithium niobate crystal doped with magnesium oxide LiNbO3:MgO is measured at liquid nitrogen and helium temperatures. On the basis of the experimental data, the coefficients of the Sellmeier equation are determined for the temperatures from 5 to 300 K. In addition, a poling period of the nonlinear crystal has been calculated for observing type-0 spontaneous parametric down-conversion (ooo-synchronism at the liquid helium temperature under pumping at the wavelength of λp = 532 nm and emission of the signal field at the wavelength of λs = 794 nm, which corresponds to the resonant absorption line of Tm3+ doped ions.

  10. Neutron fluence-to-dose equivalent conversion factors: a comparison of data sets and interpolation methods

    International Nuclear Information System (INIS)

    Sims, C.S.; Killough, G.G.

    1983-01-01

    Various segments of the health physics community advocate the use of different sets of neutron fluence-to-dose equivalent conversion factors as a function of energy and different methods of interpolation between discrete points in those data sets. The major data sets and interpolation methods are used to calculate the spectrum average fluence-to-dose equivalent conversion factors for five spectra associated with the various shielded conditions of the Health Physics Research Reactor. The results obtained by use of the different data sets and interpolation methods are compared and discussed. (author)

  11. Novel anti-jamming technique for OCDMA network through FWM in SOA based wavelength converter

    Science.gov (United States)

    Jyoti, Vishav; Kaler, R. S.

    2013-06-01

    In this paper, we propose a novel anti-jamming technique for optical code division multiple access (OCDMA) network through four wave mixing (FWM) in semiconductor optical amplifier (SOA) based wavelength converter. OCDMA signal can be easily jammed with high power jamming signal. It is shown that wavelength conversion through four wave mixing in SOA has improved capability of jamming resistance. It is observed that jammer has no effect on OCDMA network even at high jamming powers by using the proposed technique.

  12. Effective dose per unit kerma-area product conversion factors in adults undergoing modified barium swallow studies

    International Nuclear Information System (INIS)

    Shaw Bonilha, Heather; Wilmskoetter, Janina; Tipnis, Sameer V.; Martin-Harris, Bonnie; Huda, Walter

    2017-01-01

    This study presents an investigation of adult effective dose (E) per unit Kerma-Area Product (KAP) in Modified Barium Swallow Study (MBSS) examinations. PC program for X-ray Monte Carlo (version 2.0.1) was used to calculate patient organ doses during MBSS examinations, which used combined to generate effective dose. Normalized patient doses were obtained by dividing the effective dose (mSv) by the incident KAP (Gy.cm 2 ). Five standard projections were studied and the importance of X-ray beam size and in patient size (body mass index) were investigated. Lateral projections had an average E/ KAP conversion factor of 0.19 ± 0.04 mSv/Gy.cm 2 . The average E/KAP was highest for upper gastrointestinal (GI) anterior- posterior projections (0.27 ± 0.04 mSv/Gy.cm 2 ) and lowest for upper GI posterior-anterior projections (0.09 ± 0.03 mSv/ Gy.cm 2 ). E/KAP always increased with increasing filtration and/or X-ray tube voltage. Reducing the X-ray beam cross-sectional area increased the E/KAP conversion factors. Small patients have the E/KAP conversion factors that are twice those of a standard adult. Conversion factors for effective dose of adult patients undergoing MBSS examinations must account for X-ray beam projection, beam quality (kV and filtration), image size and patient size. (authors)

  13. A feasibility assessment of calculation procedure with case study and the modification of dose conversion factor in STARDOSE

    International Nuclear Information System (INIS)

    Ko, H. S.; Jang, M.; Kim, S. H.; Kang, C. S.

    2003-01-01

    STARDOSE computer code is the designed code for which is calculated the dose of control room and off-site dose on design basis accident of nuclear power plant. Input files of STARDOSE are libfile1.txt which has decay constant and dose conversion factor, and input.dat which structurally expresses the real plant model by editor. It is given much advanced result with using newer dose conversion factor in libfile1.txt. In this study, therefore, case study is performed that is made input.dat file for LOCA and libfile1.txt which is included newer dose conversion factor and core inventory on APR-1400 and UCN 5 and 6. The result of case study is compared and analyzed

  14. Characterization of a Wavelength Converter for 256-QAM Signals Based on an AlGaAs-On-Insulator Nano-waveguide

    DEFF Research Database (Denmark)

    Da Ros, Francesco; Yankov, Metodi Plamenov; Porto da Silva, Edson

    2016-01-01

    High efficiency and broadband wavelength conversion in a 9-mm AlGaAs-On-Insulator waveguide is shown to provide high-quality (OSNR > 30 dB) idler generation over a 28-nm bandwidth enabling error-free conversion of 10-GBd 256-QAM with OSNR penalty below 2.5 dB....

  15. Application of the dose conversion factor for a NaI(Tl) detector to the radwaste drum assay

    International Nuclear Information System (INIS)

    Ji, Young-Yong; Hong, Dae-Seok; Kim, Tae-Kuk; Kwak, Kyung-Kil; Ryu, Woo-Seog

    2011-01-01

    The dose-to-curie (DTC) conversion method has been known that there could be extremely high uncertainty associated with establishing the radioactivity of gamma emitters in a drum. However, the DTC conversion method is still an effective assay method to calculate the radioisotope inventory because of the simple and easy procedures to be applied. In order to make the DTC conversion method practical, numerous assumptions and limitations placed on its use. These assumptions and limitations are related to the dose rate measurement and the relative abundance of gamma emitters in a drum. However, these two variables were generally obtained from the different detection mechanisms even using the different radwaste each other. Unfortunately, that expanded the limitation of using the DTC conversion method. In order to obtain two variables in a drum to be assayed at once, the dose conversion factor for a NaI(Tl) detector was first calculated from the MCNP code. The pulse height spectrum from a simulated drum inserted into a standard source was measured by a NaI(Tl) detector, and then, two variables were calculated from the dose conversion factor and the net count rate of detected gamma emitters in the pulse height spectrum.

  16. Biosphere dose conversion Factor Importance and Sensitivity Analysis

    International Nuclear Information System (INIS)

    M. Wasiolek

    2004-01-01

    This report presents importance and sensitivity analysis for the environmental radiation model for Yucca Mountain, Nevada (ERMYN). ERMYN is a biosphere model supporting the total system performance assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis concerns the output of the model, biosphere dose conversion factors (BDCFs) for the groundwater, and the volcanic ash exposure scenarios. It identifies important processes and parameters that influence the BDCF values and distributions, enhances understanding of the relative importance of the physical and environmental processes on the outcome of the biosphere model, includes a detailed pathway analysis for key radionuclides, and evaluates the appropriateness of selected parameter values that are not site-specific or have large uncertainty

  17. Diode-side-pumped 131 W, 1319 nm single-wavelength cw Nd:YAG laser.

    Science.gov (United States)

    Haiyong, Zhu; Ge, Zhang; Chenghui, Huang; Yong, Wei; Lingxiong, Huang; Jing, Chen; Weidong, Chen; Zhenqiang, Chen

    2007-01-20

    A diode-side-pumped high-power 1319 nm single-wavelength Nd:YAG continuous wave (cw) laser is described. Through reasonable coating design of the cavity mirrors, the 1064 nm strongest line as well as the 1338 nm one have been successfully suppressed. The laser output powers corresponding to four groups of different output couplers operating at 1319 nm single wavelength have been compared. The output coupler with the transmission T=5.3% has the highest output power, and a 131 W cw output power was achieved at the pumping power of 555 W. The optical-optical conversion efficiency is 23.6%, and the slope efficiency is 46%. The output power is higher than the total output power of the dual-wavelength laser operating at 1319 nm and 1338 nm in the experiment.

  18. Efficient telecom to visible wavelength conversion in doubly resonant gallium phosphide microdisks

    Science.gov (United States)

    Lake, David P.; Mitchell, Matthew; Jayakumar, Harishankar; dos Santos, Laís Fujii; Curic, Davor; Barclay, Paul E.

    2016-01-01

    Resonant second harmonic generation between 1550 nm and 775 nm with normalized outside efficiency > 3.8 × 10 - 4 mW - 1 is demonstrated in a gallium phosphide microdisk supporting high-Q modes at visible ( Q ˜ 10 4 ) and infrared ( Q ˜ 10 5 ) wavelengths. The double resonance condition is satisfied for a specific pump power through intracavity photothermal temperature tuning using ˜ 360 μ W of 1550 nm light input to a fiber taper and coupled to a microdisk resonance. Power dependent efficiency consistent with a simple model for thermal tuning of the double resonance condition is observed.

  19. Assessment of dose conversion factors in a generic biosphere of a Korea HLW repository

    International Nuclear Information System (INIS)

    Hwang, Y. S.; Park, J. B.; Kang, C. H.

    2002-01-01

    Radioactive species released from a waste repository migrate through engineered and natural barriers and eventually reach the biosphere. Once entered the biosphere, contaminants transport various exposure pathways and finally reach a human. In this study the full RES matrix explaining the key compartments in the biosphere and their interactions is introduced considering the characteristics of the Korean biosphere. Then the three exposure groups are identified based on the compartments of interest. The full exposure pathways and corresponding mathematical expression for mass transfer coefficients and etc are developed and applied to assess the dose conversion factors of nuclides for a specific exposure group. Dose conversion factors assessed in this study will be used for total system performance assessment of a potential Korean HLW repository

  20. Disruptive Event Biosphere Dose Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M. Wasiolek

    2004-09-08

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the total system performance assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the volcanic ash exposure scenario, and the development of dose factors for calculating inhalation dose during volcanic eruption. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the Biosphere Model Report in Figure 1-1, contain detailed descriptions of the model input parameters, their development and the relationship between the parameters and specific features, events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the volcanic ash exposure scenario. This analysis receives direct input from the outputs of the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) and from the five analyses that develop parameter values for the biosphere model (BSC 2004 [DIRS 169671]; BSC 2004 [DIRS 169672]; BSC 2004 [DIRS 169673]; BSC 2004 [DIRS 169458]; and BSC 2004 [DIRS 169459]). The results of this report are further analyzed in the ''Biosphere Dose Conversion Factor Importance and Sensitivity Analysis''. The objective of this

  1. Disruptive Event Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    M. Wasiolek

    2004-01-01

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the total system performance assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the volcanic ash exposure scenario, and the development of dose factors for calculating inhalation dose during volcanic eruption. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the Biosphere Model Report in Figure 1-1, contain detailed descriptions of the model input parameters, their development and the relationship between the parameters and specific features, events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the volcanic ash exposure scenario. This analysis receives direct input from the outputs of the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) and from the five analyses that develop parameter values for the biosphere model (BSC 2004 [DIRS 169671]; BSC 2004 [DIRS 169672]; BSC 2004 [DIRS 169673]; BSC 2004 [DIRS 169458]; and BSC 2004 [DIRS 169459]). The results of this report are further analyzed in the ''Biosphere Dose Conversion Factor Importance and Sensitivity Analysis''. The objective of this analysis was to develop the BDCFs for the volcanic ash

  2. DISRUPTIVE EVENT BIOSPHERE DOSE CONVERSION FACTOR ANALYSIS

    International Nuclear Information System (INIS)

    M.A. Wasiolek

    2005-01-01

    This analysis report is one of the technical reports containing documentation of the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), a biosphere model supporting the total system performance assessment (TSPA) for the license application (LA) for the Yucca Mountain repository. This analysis report describes the development of biosphere dose conversion factors (BDCFs) for the volcanic ash exposure scenario, and the development of dose factors for calculating inhalation dose during volcanic eruption. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of two reports that develop biosphere BDCFs, which are input parameters for the TSPA model. The Biosphere Model Report (BSC 2004 [DIRS 169460]) describes in detail the ERMYN conceptual model and mathematical model. The input parameter reports, shown to the right of the Biosphere Model Report in Figure 1-1, contain detailed descriptions of the model input parameters, their development and the relationship between the parameters and specific features, events and processes (FEPs). This report describes biosphere model calculations and their output, the BDCFs, for the volcanic ash exposure scenario. This analysis receives direct input from the outputs of the ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) and from the five analyses that develop parameter values for the biosphere model (BSC 2005 [DIRS 172827]; BSC 2004 [DIRS 169672]; BSC 2004 [DIRS 169673]; BSC 2004 [DIRS 169458]; and BSC 2004 [DIRS 169459]). The results of this report are further analyzed in the ''Biosphere Dose Conversion Factor Importance and Sensitivity Analysis'' (Figure 1-1). The objective of this analysis was to develop the BDCFs for the volcanic

  3. Wavelength shifting reflector foils for liquid Ar scintillation light

    Energy Technology Data Exchange (ETDEWEB)

    Walter, Manuel [Physik Institut, Universitaet Zuerich (Switzerland); Collaboration: GERDA-Collaboration

    2013-07-01

    Liquid argon is used as a scintillator in several present and upcoming experiments. In Gerda it is used as a coolant, shielding and will be instrumented to become an active veto in Phase II. Its scintillation light has a wavelength of 128 nm, that gets absorbed by quartz. In order to measure the light using photo multiplier tubes (PMT) for cryogenic temperatures which have a quartz window, it is converted to longer wavelength by coated reflector foils. The conversion efficiency and stability of several such coatings was optimized using VM2000 and Tetratex separately as reflector foils. The efficiency has been measured in a liquid Ar set up build especially for this purpose. It employs a 3'' low radioactivity PMT of type R11065-10 from Hamamatsu, the favorite photo sensor candidate to be used in Gerda.

  4. Discrete parametric band conversion in silicon for mid-infrared applications.

    Science.gov (United States)

    Tien, En-Kuang; Huang, Yuewang; Gao, Shiming; Song, Qi; Qian, Feng; Kalyoncu, Salih K; Boyraz, Ozdal

    2010-10-11

    Silicon photonics has great potential for mid-wave-infrared applications. The dispersion of waveguide can be manipulated by waveguide dimension and cladding materials. Simulation shows that <3 μm wide conversion can be achieved by tuning the pump wavelength.

  5. MIT wavelength tables. Volume 2. Wavelengths by element

    International Nuclear Information System (INIS)

    Phelps, F.M. III.

    1982-01-01

    This volume is the first stage of a project to expand and update the MIT wavelength tables first compiled in the 1930's. For 109,325 atomic emission lines, arranged by element, it presents wavelength in air, wavelength in vacuum, wave number and intensity. All data are stored on computer-readable magnetic tape

  6. Development and application of a complex numerical model and software for the computation of dose conversion factors for radon progenies.

    Science.gov (United States)

    Farkas, Árpád; Balásházy, Imre

    2015-04-01

    A more exact determination of dose conversion factors associated with radon progeny inhalation was possible due to the advancements in epidemiological health risk estimates in the last years. The enhancement of computational power and the development of numerical techniques allow computing dose conversion factors with increasing reliability. The objective of this study was to develop an integrated model and software based on a self-developed airway deposition code, an own bronchial dosimetry model and the computational methods accepted by International Commission on Radiological Protection (ICRP) to calculate dose conversion coefficients for different exposure conditions. The model was tested by its application for exposure and breathing conditions characteristic of mines and homes. The dose conversion factors were 8 and 16 mSv WLM(-1) for homes and mines when applying a stochastic deposition model combined with the ICRP dosimetry model (named PM-A model), and 9 and 17 mSv WLM(-1) when applying the same deposition model combined with authors' bronchial dosimetry model and the ICRP bronchiolar and alveolar-interstitial dosimetry model (called PM-B model). User friendly software for the computation of dose conversion factors has also been developed. The software allows one to compute conversion factors for a large range of exposure and breathing parameters and to perform sensitivity analyses. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Total Protein Content Determination of Microalgal Biomass by Elemental Nitrogen Analysis and a Dedicated Nitrogen-to-Protein Conversion Factor

    Energy Technology Data Exchange (ETDEWEB)

    Laurens, Lieve M [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Olstad-Thompson, Jessica L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Templeton, David W [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-04-02

    Accurately determining protein content is important in the valorization of algal biomass in food, feed, and fuel markets, where these values are used for component balance calculations. Conversion of elemental nitrogen to protein is a well-accepted and widely practiced method, but depends on developing an applicable nitrogen-to-protein conversion factor. The methodology reported here covers the quantitative assessment of the total nitrogen content of algal biomass and a description of the methodology that underpins the accurate de novo calculation of a dedicated nitrogen-to-protein conversion factor.

  8. The Generalized Conversion Factor in Einstein's Mass-Energy Equation

    Directory of Open Access Journals (Sweden)

    Ajay Sharma

    2008-07-01

    Full Text Available Einstein's September 1905 paper is origin of light energy-mass inter conversion equation ($L = Delta mc^{2}$ and Einstein speculated $E = Delta mc^{2}$ from it by simply replacing $L$ by $E$. From its critical analysis it follows that $L = Delta mc^{2}$ is only true under special or ideal conditions. Under general cases the result is $L propto Delta mc^{2}$ ($E propto Delta mc^{2}$. Consequently an alternate equation $Delta E = A ub c^{2}Delta M$ has been suggested, which implies that energy emitted on annihilation of mass can be equal, less and more than predicted by $Delta E = Delta mc^{2}$. The total kinetic energy of fission fragments of U-235 or Pu-239 is found experimentally 20-60 MeV less than Q-value predicted by $Delta mc^{2}$. The mass of particle Ds (2317 discovered at SLAC, is more than current estimates. In many reactions including chemical reactions $E = Delta mc^{2}$ is not confirmed yet, but regarded as true. It implies the conversion factor than $c^{2}$ is possible. These phenomena can be explained with help of generalized mass-energy equation $Delta E = A ub c^{2}Delta M$.

  9. Tm2+ luminescent materials for solar radiation conversion devices

    NARCIS (Netherlands)

    Van der Kolk, E.

    2015-01-01

    A solar radiation conversion device is described that comprises a luminescent Tm 2+ inorganic material for converting solar radiation of at least part of the UV and/or visible and/or infra red solar spectrum into infrared solar radiation, preferably said infrared solar radiation having a wavelength

  10. Estimating Effective Dose of Radiation From Pediatric Cardiac CT Angiography Using a 64-MDCT Scanner: New Conversion Factors Relating Dose-Length Product to Effective Dose.

    Science.gov (United States)

    Trattner, Sigal; Chelliah, Anjali; Prinsen, Peter; Ruzal-Shapiro, Carrie B; Xu, Yanping; Jambawalikar, Sachin; Amurao, Maxwell; Einstein, Andrew J

    2017-03-01

    The purpose of this study is to determine the conversion factors that enable accurate estimation of the effective dose (ED) used for cardiac 64-MDCT angiography performed for children. Anthropomorphic phantoms representative of 1- and 10-year-old children, with 50 metal oxide semiconductor field-effect transistor dosimeters placed in organs, underwent scanning performed using a 64-MDCT scanner with different routine clinical cardiac scan modes and x-ray tube potentials. Organ doses were used to calculate the ED on the basis of weighting factors published in 1991 in International Commission on Radiological Protection (ICRP) publication 60 and in 2007 in ICRP publication 103. The EDs and the scanner-reported dose-length products were used to determine conversion factors for each scan mode. The effect of infant heart rate on the ED and the conversion factors was also assessed. The mean conversion factors calculated using the current definition of ED that appeared in ICRP publication 103 were as follows: 0.099 mSv · mGy -1 · cm -1 , for the 1-year-old phantom, and 0.049 mSv · mGy -1 · cm -1 , for the 10-year-old phantom. These conversion factors were a mean of 37% higher than the corresponding conversion factors calculated using the older definition of ED that appeared in ICRP publication 60. Varying the heart rate did not influence the ED or the conversion factors. Conversion factors determined using the definition of ED in ICRP publication 103 and cardiac, rather than chest, scan coverage suggest that the radiation doses that children receive from cardiac CT performed using a contemporary 64-MDCT scanner are higher than the radiation doses previously reported when older chest conversion factors were used. Additional up-to-date pediatric cardiac CT conversion factors are required for use with other contemporary CT scanners and patients of different age ranges.

  11. Systematic comparison of FWM conversion efficiency in silicon waveguides and MRRs

    DEFF Research Database (Denmark)

    Xiong, Meng; Ding, Yunhong; Ou, Haiyan

    2013-01-01

    Wavelength conversion based on four-wave mixing is theoretically compared in silicon micro-ring resonators and nanowires under the effect of nonlinear loss. The impact of the bus waveguide length and MRR position are also quantified....

  12. Disruptive Event Biosphere Dose Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M. A. Wasiolek

    2003-07-21

    This analysis report, ''Disruptive Event Biosphere Dose Conversion Factor Analysis'', is one of the technical reports containing documentation of the ERMYN (Environmental Radiation Model for Yucca Mountain Nevada) biosphere model for the geologic repository at Yucca Mountain, its input parameters, and the application of the model to perform the dose assessment for the repository. The biosphere model is one of a series of process models supporting the Total System Performance Assessment (TSPA) for the Yucca Mountain repository. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of the two reports that develop biosphere dose conversion factors (BDCFs), which are input parameters for the TSPA model. The ''Biosphere Model Report'' (BSC 2003 [DIRS 164186]) describes in detail the conceptual model as well as the mathematical model and lists its input parameters. Model input parameters are developed and described in detail in five analysis report (BSC 2003 [DIRS 160964], BSC 2003 [DIRS 160965], BSC 2003 [DIRS 160976], BSC 2003 [DIRS 161239], and BSC 2003 [DIRS 161241]). The objective of this analysis was to develop the BDCFs for the volcanic ash exposure scenario and the dose factors (DFs) for calculating inhalation doses during volcanic eruption (eruption phase of the volcanic event). The volcanic ash exposure scenario is hereafter referred to as the volcanic ash scenario. For the volcanic ash scenario, the mode of radionuclide release into the biosphere is a volcanic eruption through the repository with the resulting entrainment of contaminated waste in the tephra and the subsequent atmospheric transport and dispersion of contaminated material in

  13. Disruptive Event Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    M. A. Wasiolek

    2003-01-01

    This analysis report, ''Disruptive Event Biosphere Dose Conversion Factor Analysis'', is one of the technical reports containing documentation of the ERMYN (Environmental Radiation Model for Yucca Mountain Nevada) biosphere model for the geologic repository at Yucca Mountain, its input parameters, and the application of the model to perform the dose assessment for the repository. The biosphere model is one of a series of process models supporting the Total System Performance Assessment (TSPA) for the Yucca Mountain repository. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and provides an understanding of how this analysis report contributes to biosphere modeling. This report is one of the two reports that develop biosphere dose conversion factors (BDCFs), which are input parameters for the TSPA model. The ''Biosphere Model Report'' (BSC 2003 [DIRS 164186]) describes in detail the conceptual model as well as the mathematical model and lists its input parameters. Model input parameters are developed and described in detail in five analysis report (BSC 2003 [DIRS 160964], BSC 2003 [DIRS 160965], BSC 2003 [DIRS 160976], BSC 2003 [DIRS 161239], and BSC 2003 [DIRS 161241]). The objective of this analysis was to develop the BDCFs for the volcanic ash exposure scenario and the dose factors (DFs) for calculating inhalation doses during volcanic eruption (eruption phase of the volcanic event). The volcanic ash exposure scenario is hereafter referred to as the volcanic ash scenario. For the volcanic ash scenario, the mode of radionuclide release into the biosphere is a volcanic eruption through the repository with the resulting entrainment of contaminated waste in the tephra and the subsequent atmospheric transport and dispersion of contaminated material in the biosphere. The biosphere process

  14. The "polyenviromic risk score": Aggregating environmental risk factors predicts conversion to psychosis in familial high-risk subjects.

    Science.gov (United States)

    Padmanabhan, Jaya L; Shah, Jai L; Tandon, Neeraj; Keshavan, Matcheri S

    2017-03-01

    Young relatives of individuals with schizophrenia (i.e. youth at familial high-risk, FHR) are at increased risk of developing psychotic disorders, and show higher rates of psychiatric symptoms, cognitive and neurobiological abnormalities than non-relatives. It is not known whether overall exposure to environmental risk factors increases risk of conversion to psychosis in FHR subjects. Subjects consisted of a pilot longitudinal sample of 83 young FHR subjects. As a proof of principle, we examined whether an aggregate score of exposure to environmental risk factors, which we term a 'polyenviromic risk score' (PERS), could predict conversion to psychosis. The PERS combines known environmental risk factors including cannabis use, urbanicity, season of birth, paternal age, obstetric and perinatal complications, and various types of childhood adversity, each weighted by its odds ratio for association with psychosis in the literature. A higher PERS was significantly associated with conversion to psychosis in young, familial high-risk subjects (OR=1.97, p=0.009). A model combining the PERS and clinical predictors had a sensitivity of 27% and specificity of 96%. An aggregate index of environmental risk may help predict conversion to psychosis in FHR subjects. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Increasing Restorability for Local-to-Egress Restoration in GMPLS Controlled Networks with Limited Wavelength Conversion

    DEFF Research Database (Denmark)

    Ruepp, Sarah Renée; Buron, Jakob Due; Andriolli, N.

    2006-01-01

    We study the performance of the local-to-egress restoration method in GMPLS controlled optical networks, when a limited number of wavelength converters are available. We evaluate the recovery percentage for a converter-saving label assignment scheme and compare its performance to a simple scheme...

  16. Cathecol-O-methyl transferase Val158Met genotype is not a risk factor for conversion disorder.

    Science.gov (United States)

    Armagan, E; Almacıoglu, M L; Yakut, T; Köse, A; Karkucak, M; Köksal, O; Görükmez, O

    2013-03-19

    Alterations in catechol-O-methyltransferase (COMT) activity are involved in various types of neurological disorders. We examined a possible association between the COMT Val158Met polymorphism and conversion disorder in a study of 48 patients with conversion disorder and 48 control patients. In the conversion disorder group, 31 patients were Val/Met heterozygotes, 15 patients were Val/Val homozygotes and 2 patients were Met/Met homozygotes. In the control group, 32 patients were Val/Met heterozygotes and 16 patients were Val/Val homozygotes. There was no significant difference between the groups. We conclude that the COMT Val158Met genotype is quite common in Turkey and that it is not a risk factor for conversion disorder in the Turkish population.

  17. Biomass recalcitrance: a multi-scale, multi-factor, and conversion-specific property.

    Science.gov (United States)

    McCann, Maureen C; Carpita, Nicholas C

    2015-07-01

    Recalcitrance of plant biomass to enzymatic hydrolysis for biofuel production is thought to be a property conferred by lignin or lignin-carbohydrate complexes. However, chemical catalytic and thermochemical conversion pathways, either alone or in combination with biochemical and fermentative pathways, now provide avenues to utilize lignin and to expand the product range beyond ethanol or butanol. To capture all of the carbon in renewable biomass, both lignin-derived aromatics and polysaccharide-derived sugars need to be transformed by catalysts to liquid hydrocarbons and high-value co-products. We offer a new definition of recalcitrance as those features of biomass which disproportionately increase energy requirements in conversion processes, increase the cost and complexity of operations in the biorefinery, and/or reduce the recovery of biomass carbon into desired products. The application of novel processing technologies applied to biomass reveal new determinants of recalcitrance that comprise a broad range of molecular, nanoscale, and macroscale factors. Sampling natural genetic diversity within a species, transgenic approaches, and synthetic biology approaches are all strategies that can be used to select biomass for reduced recalcitrance in various pretreatments and conversion pathways. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  18. Illumination wavelength and time dependent nano gold photo-deposition and CO oxidation

    Directory of Open Access Journals (Sweden)

    Siewhui Chong

    Full Text Available In this study, nano gold (Au was deposited on titanium dioxide (TiO2 of different morphologies and crystallinities by photo-deposition method under LED irradiation with various wavelengths and irradiation times. The reactivity of carbon monoxide (CO oxidation of the as-prepared catalysts was examined and correlated with the characteristics of TiO2 support and gold particles. Characterization and activity tests showed that the effective illumination wavelength of photo-deposition is strongly determined by the band-gap of TiO2. Au/Cubic-TiO2 (450 nm, 5 min yielded comparatively highest CO conversion of 71%, followed by Au/P25 (375 nm, 1 min and Au/ST21 (340 nm, 1 min. When the photon energy of the LED is lower than the band-gap of TiO2, CO conversion rate increases with the irradiation time due to the decrease in gold particle size which could possibly due to the lower speed of photo-deposition compared to that of concentration diffusion. Keywords: Gold, Catalyst, TiO2, Photodeposition, Carbon monoxide, Oxidation

  19. Factors Affecting Time to Sputum Culture Conversion in Adults with Pulmonary Tuberculosis: A Historical Cohort Study without Censored Cases.

    Science.gov (United States)

    Kanda, Rie; Nagao, Taishi; Tho, Nguyen Van; Ogawa, Emiko; Murakami, Yoshitaka; Osawa, Makoto; Saika, Yoshinori; Doi, Kenji; Nakano, Yasutaka

    2015-01-01

    In patients with pulmonary tuberculosis (TB), shortening the time to sputum culture conversion is desirable to reduce the likelihood of mycobacterial transmission. A persistent positive sputum culture after 2 months of treatment is reported to be associated with the presence of cavitation and the extent of disease on chest X-ray, high colony count, diabetes mellitus, and smoking. However, little is known about factors affecting the time to sputum culture conversion. This study was conducted to evaluate factors affecting the time to sputum culture conversion throughout the course of treatment in adults with pulmonary TB. This study was performed using a database of the medical records of patients with active pulmonary TB who were treated at Hirakata Kohsai Hospital in Hirakata City, Osaka, Japan, from October 2000 to October 2002. Cox proportional-hazards analysis was used to evaluate factors affecting the time to sputum culture conversion after adjusting for potential confounders. The data of 86 patients with pulmonary TB were analyzed. The median time to sputum culture conversion was 39 days, and the maximum time was 116 days. The Cox proportional-hazards analysis showed that a higher smear grading (HR, 0.40; 95%CI, 0.23-0.71) and a history of ever smoking (HR, 0.48; 95%CI, 0.25-0.94) were associated with delayed sputum culture conversion. High smear grading and smoking prolonged the time to sputum culture conversion in adults with pulmonary TB. To effectively control TB, measures to decrease the cigarette smoking rate should be implemented, in addition to early detection and timely anti-TB treatment.

  20. Conversion of Human Fibroblasts to Stably Self-Renewing Neural Stem Cells with a Single Zinc-Finger Transcription Factor

    Directory of Open Access Journals (Sweden)

    Ebrahim Shahbazi

    2016-04-01

    Full Text Available Direct conversion of somatic cells into neural stem cells (NSCs by defined factors holds great promise for mechanistic studies, drug screening, and potential cell therapies for different neurodegenerative diseases. Here, we report that a single zinc-finger transcription factor, Zfp521, is sufficient for direct conversion of human fibroblasts into long-term self-renewable and multipotent NSCs. In vitro, Zfp521-induced NSCs maintained their characteristics in the absence of exogenous factor expression and exhibited morphological, molecular, developmental, and functional properties that were similar to control NSCs. In addition, the single-seeded induced NSCs were able to form NSC colonies with efficiency comparable with control NSCs and expressed NSC markers. The converted cells were capable of surviving, migrating, and attaining neural phenotypes after transplantation into neonatal mouse and adult rat brains, without forming tumors. Moreover, the Zfp521-induced NSCs predominantly expressed rostral genes. Our results suggest a facilitated approach for establishing human NSCs through Zfp521-driven conversion of fibroblasts.

  1. Factors Affecting Time to Sputum Culture Conversion in Adults with Pulmonary Tuberculosis: A Historical Cohort Study without Censored Cases.

    Directory of Open Access Journals (Sweden)

    Rie Kanda

    Full Text Available In patients with pulmonary tuberculosis (TB, shortening the time to sputum culture conversion is desirable to reduce the likelihood of mycobacterial transmission. A persistent positive sputum culture after 2 months of treatment is reported to be associated with the presence of cavitation and the extent of disease on chest X-ray, high colony count, diabetes mellitus, and smoking. However, little is known about factors affecting the time to sputum culture conversion. This study was conducted to evaluate factors affecting the time to sputum culture conversion throughout the course of treatment in adults with pulmonary TB.This study was performed using a database of the medical records of patients with active pulmonary TB who were treated at Hirakata Kohsai Hospital in Hirakata City, Osaka, Japan, from October 2000 to October 2002. Cox proportional-hazards analysis was used to evaluate factors affecting the time to sputum culture conversion after adjusting for potential confounders.The data of 86 patients with pulmonary TB were analyzed. The median time to sputum culture conversion was 39 days, and the maximum time was 116 days. The Cox proportional-hazards analysis showed that a higher smear grading (HR, 0.40; 95%CI, 0.23-0.71 and a history of ever smoking (HR, 0.48; 95%CI, 0.25-0.94 were associated with delayed sputum culture conversion.High smear grading and smoking prolonged the time to sputum culture conversion in adults with pulmonary TB. To effectively control TB, measures to decrease the cigarette smoking rate should be implemented, in addition to early detection and timely anti-TB treatment.

  2. Optical Cherenkov radiation in an As2S3 slot waveguide with four zero-dispersion wavelengths

    DEFF Research Database (Denmark)

    Wang, Shaofei; Hu, Jungao; Guo, Hairun

    2013-01-01

    , dispersion profiles with four zero dispersion wavelengths are found to produce a phase-matching nonlinear process leading to a broadband resonant radiation. The broadband OCR investigated in the chalcogenide waveguide may find applications in on-chip wavelength conversion and near-infrared pulse generation.......We propose an approach for an efficient generation of optical Cherenkov radiation (OCR) in the near-infrared by tailoring the waveguide dispersion for a zero group-velocity mismatching between the radiation and the pump soliton. Based on an As2S3 slot waveguide with subwavelength dimensions...

  3. Quantum frequency conversion with ultra-broadband tuning in a Raman memory

    Science.gov (United States)

    Bustard, Philip J.; England, Duncan G.; Heshami, Khabat; Kupchak, Connor; Sussman, Benjamin J.

    2017-05-01

    Quantum frequency conversion is a powerful tool for the construction of hybrid quantum photonic technologies. Raman quantum memories are a promising method of conversion due to their broad bandwidths. Here we demonstrate frequency conversion of THz-bandwidth, fs-duration photons at the single-photon level using a Raman quantum memory based on the rotational levels of hydrogen molecules. We shift photons from 765 nm to wavelengths spanning from 673 to 590 nm—an absolute shift of up to 116 THz. We measure total conversion efficiencies of up to 10% and a maximum signal-to-noise ratio of 4.0(1):1, giving an expected conditional fidelity of 0.75, which exceeds the classical threshold of 2/3. Thermal noise could be eliminated by cooling with liquid nitrogen, giving noiseless conversion with wide tunability in the visible and infrared.

  4. Monte Carlo calculations of electron beam quality conversion factors for several ion chamber types

    Energy Technology Data Exchange (ETDEWEB)

    Muir, B. R., E-mail: Bryan.Muir@nrc-cnrc.gc.ca [Measurement Science and Standards, National Research Council Canada, 1200 Montreal Road, Ottawa, Ontario K1A 0R6 (Canada); Rogers, D. W. O., E-mail: drogers@physics.carleton.ca [Carleton Laboratory for Radiotherapy Physics, Physics Department, Carleton University, 1125 ColonelBy Drive, Ottawa, Ontario K1S 5B6 (Canada)

    2014-11-01

    Purpose: To provide a comprehensive investigation of electron beam reference dosimetry using Monte Carlo simulations of the response of 10 plane-parallel and 18 cylindrical ion chamber types. Specific emphasis is placed on the determination of the optimal shift of the chambers’ effective point of measurement (EPOM) and beam quality conversion factors. Methods: The EGSnrc system is used for calculations of the absorbed dose to gas in ion chamber models and the absorbed dose to water as a function of depth in a water phantom on which cobalt-60 and several electron beam source models are incident. The optimal EPOM shifts of the ion chambers are determined by comparing calculations of R{sub 50} converted from I{sub 50} (calculated using ion chamber simulations in phantom) to R{sub 50} calculated using simulations of the absorbed dose to water vs depth in water. Beam quality conversion factors are determined as the calculated ratio of the absorbed dose to water to the absorbed dose to air in the ion chamber at the reference depth in a cobalt-60 beam to that in electron beams. Results: For most plane-parallel chambers, the optimal EPOM shift is inside of the active cavity but different from the shift determined with water-equivalent scaling of the front window of the chamber. These optimal shifts for plane-parallel chambers also reduce the scatter of beam quality conversion factors, k{sub Q}, as a function of R{sub 50}. The optimal shift of cylindrical chambers is found to be less than the 0.5 r{sub cav} recommended by current dosimetry protocols. In most cases, the values of the optimal shift are close to 0.3 r{sub cav}. Values of k{sub ecal} are calculated and compared to those from the TG-51 protocol and differences are explained using accurate individual correction factors for a subset of ion chambers investigated. High-precision fits to beam quality conversion factors normalized to unity in a beam with R{sub 50} = 7.5 cm (k{sub Q}{sup ′}) are provided. These

  5. CT- and MRI-based volumetry of resected liver specimen: Comparison to intraoperative volume and weight measurements and calculation of conversion factors

    International Nuclear Information System (INIS)

    Karlo, C.; Reiner, C.S.; Stolzmann, P.; Breitenstein, S.; Marincek, B.; Weishaupt, D.; Frauenfelder, T.

    2010-01-01

    Objective: To compare virtual volume to intraoperative volume and weight measurements of resected liver specimen and calculate appropriate conversion factors to reach better correlation. Methods: Preoperative (CT-group, n = 30; MRI-group, n = 30) and postoperative MRI (n = 60) imaging was performed in 60 patients undergoing partial liver resection. Intraoperative volume and weight of the resected liver specimen was measured. Virtual volume measurements were performed by two readers (R1,R2) using dedicated software. Conversion factors were calculated. Results: Mean intraoperative resection weight/volume: CT: 855 g/852 mL; MRI: 872 g/860 mL. Virtual resection volume: CT: 960 mL(R1), 982 mL(R2); MRI: 1112 mL(R1), 1115 mL(R2). Strong positive correlation for both readers between intraoperative and virtual measurements, mean of both readers: CT: R = 0.88(volume), R = 0.89(weight); MRI: R = 0.95(volume), R = 0.92(weight). Conversion factors: 0.85(CT), 0.78(MRI). Conclusion: CT- or MRI-based volumetry of resected liver specimen is accurate and recommended for preoperative planning. A conversion of the result is necessary to improve intraoperative and virtual measurement correlation. We found 0.85 for CT- and 0.78 for MRI-based volumetry the most appropriate conversion factors.

  6. Risk factors for failed conversion of labor epidural analgesia to cesarean delivery anesthesia: a systematic review and meta-analysis of observational trials.

    Science.gov (United States)

    Bauer, M E; Kountanis, J A; Tsen, L C; Greenfield, M L; Mhyre, J M

    2012-10-01

    This systematic review and meta-analysis evaluates evidence for seven risk factors associated with failed conversion of labor epidural analgesia to cesarean delivery anesthesia. Online scientific literature databases were searched using a strategy which identified observational trials, published between January 1979 and May 2011, which evaluated risk factors for failed conversion of epidural analgesia to anesthesia or documented a failure rate resulting in general anesthesia. 1450 trials were screened, and 13 trials were included for review (n=8628). Three factors increase the risk for failed conversion: an increasing number of clinician-administered boluses during labor (OR=3.2, 95% CI 1.8-5.5), greater urgency for cesarean delivery (OR=40.4, 95% CI 8.8-186), and a non-obstetric anesthesiologist providing care (OR=4.6, 95% CI 1.8-11.5). Insufficient evidence is available to support combined spinal-epidural versus standard epidural techniques, duration of epidural analgesia, cervical dilation at the time of epidural placement, and body mass index or weight as risk factors for failed epidural conversion. The risk of failed conversion of labor epidural analgesia to anesthesia is increased with an increasing number of boluses administered during labor, an enhanced urgency for cesarean delivery, and care being provided by a non-obstetric anesthesiologist. Further high-quality studies are needed to evaluate the many potential risk factors associated with failed conversion of labor epidural analgesia to anesthesia for cesarean delivery. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. Dose-rate conversion factors for external exposure to photon and electron radiation from radionuclides occurring in routine releases from nuclear fuel cycle facilities

    International Nuclear Information System (INIS)

    Kocher, D.C.

    1980-01-01

    Dose-rate conversion factors for external exposure to photon and electron radiation are calculated for 240 radionuclides of potential importance in routine releases from nuclear fuel cycle facilities. Exposure modes considered are immersion in contaminated air, immersion in contaminated water, and irradiation from a contaminated ground surface. For each exposure mode, dose-rate conversion factors for photons and electrons are calculated for tissue-equivalent material at the body surface of an exposed individual. Dose-rate conversion factors for photons only are calculated for 22 body organs. (author)

  8. Preliminary Assessment of ICRP Dose Conversion Factor Recommendations for Accident Analysis Applications

    International Nuclear Information System (INIS)

    Vincent, A.M.

    2002-01-01

    Accident analysis for U.S. Department of Energy (DOE) nuclear facilities is an integral part of the overall safety basis developed by the contractor to demonstrate facility operation can be conducted safely. An appropriate documented safety analysis for a facility discusses accident phenomenology, quantifies source terms arising from postulated process upset conditions, and applies a standardized, internationally-recognized database of dose conversion factors (DCFs) to evaluate radiological conditions to offsite receptors

  9. Defining the Minimal Factors Required for Erythropoiesis through Direct Lineage Conversion

    Directory of Open Access Journals (Sweden)

    Sandra Capellera-Garcia

    2016-06-01

    Full Text Available Erythroid cell commitment and differentiation proceed through activation of a lineage-restricted transcriptional network orchestrated by a group of well characterized genes. However, the minimal set of factors necessary for instructing red blood cell (RBC development remains undefined. We employed a screen for transcription factors allowing direct lineage reprograming from fibroblasts to induced erythroid progenitors/precursors (iEPs. We show that Gata1, Tal1, Lmo2, and c-Myc (GTLM can rapidly convert murine and human fibroblasts directly to iEPs. The transcriptional signature of murine iEPs resembled mainly that of primitive erythroid progenitors in the yolk sac, whereas addition of Klf1 or Myb to the GTLM cocktail resulted in iEPs with a more adult-type globin expression pattern. Our results demonstrate that direct lineage conversion is a suitable platform for defining and studying the core factors inducing the different waves of erythroid development.

  10. Efficient and broadband Stokes wave generation by degenerate four-wave mixing at the mid-infrared wavelength in a silica photonic crystal fiber.

    Science.gov (United States)

    Yuan, Jinhui; Sang, Xinzhu; Wu, Qiang; Zhou, Guiyao; Yu, Chongxiu; Wang, Kuiru; Yan, Binbin; Han, Ying; Farrell, Gerald; Hou, Lantian

    2013-12-15

    Based on degenerate four-wave mixing (FWM), the broadband Stokes waves are efficiently generated at the mid-infrared wavelength above 2 μm, for the first time to our knowledge, by coupling the femtosecond pulses into the fundamental mode of a silica photonic crystal fiber designed and fabricated in our laboratory. Influences of the power and wavelength of pump pulses on the phase-matched frequency conversion process are discussed. When pump pulses with central wavelength of 815 nm and average power of 300 mW are used, the output power ratio of the Stokes wave generated at 2226 nm and the residual pump wave P(s)/P(res) is estimated to be 10.8:1, and the corresponding conversion efficiency η(s) and bandwidth B(s) of the Stokes wave can be up to 26% and 33 nm, respectively. The efficient and broadband Stokes waves can be used as the ultrashort pulse sources for mid-infrared photonics and spectroscopy.

  11. 5 CFR Appendix A to Subpart C of... - Present Value Conversion Factors for Earlier Commencing Date of Annuities of Current and Former...

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 2 2010-01-01 2010-01-01 false Present Value Conversion Factors for Earlier Commencing Date of Annuities of Current and Former Spouses of Deceased Separated Employees A...—Present Value Conversion Factors for Earlier Commencing Date of Annuities of Current and Former Spouses of...

  12. Wavelength-tunable thulium-doped fiber laser by employing a self-made Fabry-Perot filter

    Science.gov (United States)

    Wang, Y. P.; Ju, Y. L.; Wu, C. T.; Liu, W.; Yang, C.

    2017-06-01

    In this demonstration, we proposed a novel wavelength-tunable thulium-doped fiber laser (TDFL) with a self-made Fabry-Perot (F-P) filter. When the F-P filter was not inserted, the maximum output power of 11.1 W was achieved when the pump power was 70.2 W. The corresponding optical-to-optical conversion efficiency was 15.8% and the slope efficiency was 22.1%. When the F-P filter was inserted, the output wavelength could be tuned from 1952.9 to 1934.9 nm with the change of cavity length of F-P filter which was fixed on a piezoelectric ceramic transducer (PZT) controlled by the voltage applied to it. The full width at half maximum (FWHM) was no more than 0.19 nm. Furthermore, the wavelength fluctuations of the tunable fiber laser were kept within  ±0.2 nm.

  13. Sexy gene conversions: locating gene conversions on the X-chromosome.

    Science.gov (United States)

    Lawson, Mark J; Zhang, Liqing

    2009-08-01

    Gene conversion can have a profound impact on both the short- and long-term evolution of genes and genomes. Here, we examined the gene families that are located on the X-chromosomes of human (Homo sapiens), chimpanzee (Pan troglodytes), mouse (Mus musculus) and rat (Rattus norvegicus) for evidence of gene conversion. We identified seven gene families (WD repeat protein family, Ferritin Heavy Chain family, RAS-related Protein RAB-40 family, Diphosphoinositol polyphosphate phosphohydrolase family, Transcription Elongation Factor A family, LDOC1-related family, Zinc Finger Protein ZIC, and GLI family) that show evidence of gene conversion. Through phylogenetic analyses and synteny evidence, we show that gene conversion has played an important role in the evolution of these gene families and that gene conversion has occurred independently in both primates and rodents. Comparing the results with those of two gene conversion prediction programs (GENECONV and Partimatrix), we found that both GENECONV and Partimatrix have very high false negative rates (i.e. failed to predict gene conversions), which leads to many undetected gene conversions. The combination of phylogenetic analyses with physical synteny evidence exhibits high resolution in the detection of gene conversions.

  14. Conversion factors: SI metric and U.S. customary units

    Science.gov (United States)

    ,

    1977-01-01

    The policy of the U.S. Geological Survey is to foster use of the International System of Units (SI) which was defined by the 11th General Conference of Weights and Measures in 1960. This modernized metric system constitutes an international "language" by means of which communications throughout the world's scientific and economic communities may be improved. This publication is designed to familiarize the reader with the SI units of measurement that correspond to the common units frequently used in programs of the Geological Survey. In the near future, SI units will be used exclusively in most publications of the Survey; the conversion factors provided herein will help readers to obtain a "feel" for each unit and to "think metric."

  15. Conversion and correction factors for historical measurements of iodine-131 in Hanford-area vegetation 1948--1951

    International Nuclear Information System (INIS)

    Denham, D.H.; Mart, E.I.; Thiede, M.E.

    1993-09-01

    This report is a part of the Hanford Environmental Dose Reconstruction (HEDR) Project, whose goal is to estimate the radiation dose that individuals could have received from emissions since 1944 at the US Department of Energy's (DOE) Hanford Site near Richland, Washington. The key radionuclide emitted that would affect the radiation dose was iodine-131 (Napier 1992). Because the early methods of measuring iodine-131 were not comparable to later techniques, conversion and correction factors are needed to convert the historical measurement data into concentration values that would be determined using today's knowledge and technologies. This report describes the conversion and correction factors developed for reconstructing historical measurements of iodine-131 in Hanford-area vegetation, which was collected from 1948 through the end of December 1951

  16. Visible-light wavelength matched microsphere assembly of TiO{sub 2} superfine nanorods and the enhanced photovoltaic performance

    Energy Technology Data Exchange (ETDEWEB)

    Tao, Xiyun; Wang, Yumin; Zhang, Xiang; Sun, Hongxia; Zhang, Qingsong; Niu, Laiyou; Liu, Juan; Zhou, Xingfu, E-mail: Zhouxf@njtech.edu.cn

    2015-05-15

    Graphical abstract: A novel visible-light wavelength matched microspheres assembly of TiO{sub 2} superfine nanorods with a diameter of ∼5 nm was fabricated via a hydrothermal method. The as-prepared rutile TiO{sub 2} microspheres have a uniform diameter of ∼450 nm and show a good light-trapping performance. Dye-sensitized solar cell based on this sample shows a satisfactory energy conversion efficiency of 6.59% and is the highest PCE reported for intrinsic rutile TiO{sub 2}. The further optimized DSSC shows a conversion efficiency of 8.3%, though the internal resistance is higher and the dye absorption is lower than that of widely used anatase TiO{sub 2} nanoparticles. - Highlights: • Microsphere assembly of TiO{sub 2} nanorods with a diameter of ∼5 nm was fabricated. • TiO{sub 2} microspheres size is well matched with the visible light wavelength. • TiO{sub 2} microsphere enhances the light-scattering ability. • Rutile TiO{sub 2} microsphere shows an energy conversion efficiency of 6.59%. • The highest PCE reported for intrinsic rutile TiO{sub 2} is obtained. - Abstract: According to the Mie scattering theory, spheres with the size matched with light wavelength are most suitable for light scattering and enhance the light trapping ability. In this paper, a novel visible-light wavelength matched sphere assembly of TiO{sub 2} superfine nanorods was fabricated via a simple one-step hydrothermal method. The morphology and the structure were examined by field emission scanning electron microscopy (FESEM), X-ray powder diffraction (XRD) and high-resolution transmission electron microscopy (HRTEM). The visible subwavelength TiO{sub 2} microsphere resembling an immature chinese chestnut is composed of countless superfine TiO{sub 2} nanorods, the diameter of these building blocks of superfine TiO{sub 2} nanorods is ∼5 nm. The obtained TiO{sub 2} sphere has an average diameter of ca. 450 nm, which matches well with the visible light wavelength and cause the

  17. Comparison of four computational methods for computing Q factors and resonance wavelengths in photonic crystal membrane cavities

    DEFF Research Database (Denmark)

    de Lasson, Jakob Rosenkrantz; Frandsen, Lars Hagedorn; Burger, Sven

    2016-01-01

    We benchmark four state-of-the-art computational methods by computing quality factors and resonance wavelengths in photonic crystal membrane L5 and L9 line defect cavities.The convergence of the methods with respect to resolution, degrees of freedom and number ofmodes is investigated. Special att...... attention is paid to the influence of the size of the computational domain. Convergence is not obtained for some of the methods, indicating that some are moresuitable than others for analyzing line defect cavities....

  18. Full-spectrum volumetric solar thermal conversion via photonic nanofluids.

    Science.gov (United States)

    Liu, Xianglei; Xuan, Yimin

    2017-10-12

    Volumetric solar thermal conversion is an emerging technique for a plethora of applications such as solar thermal power generation, desalination, and solar water splitting. However, achieving broadband solar thermal absorption via dilute nanofluids is still a daunting challenge. In this work, full-spectrum volumetric solar thermal conversion is demonstrated over a thin layer of the proposed 'photonic nanofluids'. The underlying mechanism is found to be the photonic superposition of core resonances, shell plasmons, and core-shell resonances at different wavelengths, whose coexistence is enabled by the broken symmetry of specially designed composite nanoparticles, i.e., Janus nanoparticles. The solar thermal conversion efficiency can be improved by 10.8% compared with core-shell nanofluids. The extinction coefficient of Janus dimers with various configurations is also investigated to unveil the effects of particle couplings. This work provides the possibility to achieve full-spectrum volumetric solar thermal conversion, and may have potential applications in efficient solar energy harvesting and utilization.

  19. Efficient wavelength converters with flattop responses based on counterpropagating cascaded SFG and DFG in low-loss QPM LiNbO3 waveguides.

    Science.gov (United States)

    Tehranchi, Amirhossein; Kashyap, Raman

    2009-10-12

    A wavelength converter based on counterpropagating quasi-phase matched cascaded sum and difference frequency generation in lossy lithium niobate waveguide is numerically evaluated and compared to a single-pass scheme assuming a large pump wavelength difference of 75 nm. A double-pass device is proposed to improve the conversion efficiency while the response flattening is accomplished by increasing the wavelength tuning of one pump. The criteria for the design of the low-loss waveguide length, and the assignment of power in the pumps to achieve the desired efficiency, ripple and bandwidth are presented.

  20. Experiments on quantum frequency conversion of photons

    International Nuclear Information System (INIS)

    Ramelow, S.

    2011-01-01

    Coherently converting photons between different states offers intriguing new possibilities and applications in quantum optical experiments. In this thesis three experiments on this theme are presented. The first experiment demonstrates the quantum frequency conversion of polarization entangled photons. Coherent frequency conversion of single photons offers an elegant solution for the often difficult trade-off of choosing the optimal photon wavelength, e.g. regarding optimal transmission and storage of photons in quantum memory based quantum networks. In our experiments, we verify the successful entanglement conversion by violating a Clauser-Horne-Shimony-Holt (CHSH) Bell inequality and fully characterised our close to unity fidelity entanglement transfer using quantum state- and process tomography. Our implementation is robust and flexible, making it a practical building block for future quantum technologies.The second part of the thesis introduces a deterministic scheme for photonic quantum information processing. While single photons offer many advantages for quantum information technologies, key unresolved challenges are scalable on-demand single photon sources; deterministic two-photon interactions; and near 100%-efficient detection. All these can be solved with a single versatile process - a novel four-wave mixing process that we introduce here as a special case of the more general scheme of coherent photon conversion (CPC). It can provide valuable photonic quantum processing tools, from scalably creating single- and multi-photon states to implementing deterministic entangling gates and high-efficiency detection. Notably, this would enable scalable photonic quantum computing. Using photonic crystal fibres, we experimentally demonstrate a nonlinear process suited for coherent photon conversion. We observe correlated photon-pair production at the predicted wavelengths and experimentally characterise the enhancement of the interaction strength by varying the pump

  1. Nonlinear-optical generation of short-wavelength radiation controlled by laser-induced interference structures

    International Nuclear Information System (INIS)

    Popov, A K; Kimberg, V V

    1998-01-01

    A study is reported of the combined influence of laser-induced resonances in the energy continuum, of splitting of discrete resonances in the field of several strong radiations, and of absorption of the initial and generated radiations on totally resonant parametric conversion to the short-wavelength range. It is shown that the radiation power can be increased considerably by interference processes involving quantum transitions. (nonlinear optical phenomena and devices)

  2. Determination of correction and conversion factor of exposure rate generated Gamma spectrometer GR-320 to Victoreen data

    International Nuclear Information System (INIS)

    Supardjo-AS; Mappa, Djody-Rachim; Nasrun-Syamsul; Syamsul-Hadi

    2000-01-01

    Exposure rate data of Muria Peninsula were generated from Victoreen-491 measurement and calculation of radioelement content in soil which were measured by Exploranium GR-320, using IAEA formula. However those data are not be comparable so the exposure rate calculated from Gamma Spectrometer data necessarily to be corrected. The correction factor was determinate by measuring the exposure rate of at the NMDC's back yard selected location using Victoreen-491 and Gamma Spectrometer Exploranium GR-320 . Correction factor was created by comparing mean exposure rate data that calculated from 30 data measured by Gamma Spectrometer instrument and to those Victoreen's exposure rate. Conversion factor was gained from comparing of total count data of Gamma Spectrometer Exploranium GR-320 to Victoreen's exposure rate data. The correction factor of Exploranium GR-320's exposure rate is 0.34 μR/hours, and the conversion factor of total count is 0.0092 μR/hours per c/m. Deviation Victoreen 491 = 4.7 % and Gamma Spectrometer Exploranium GR-320 8.6 %

  3. Nano Sensing and Energy Conversion Using Surface Plasmon Resonance (SPR

    Directory of Open Access Journals (Sweden)

    Iltai (Isaac Kim

    2015-07-01

    Full Text Available Nanophotonic technique has been attracting much attention in applications of nano-bio-chemical sensing and energy conversion of solar energy harvesting and enhanced energy transfer. One approach for nano-bio-chemical sensing is surface plasmon resonance (SPR imaging, which can detect the material properties, such as density, ion concentration, temperature, and effective refractive index in high sensitivity, label-free, and real-time under ambient conditions. Recent study shows that SPR can successfully detect the concentration variation of nanofluids during evaporation-induced self-assembly process. Spoof surface plasmon resonance based on multilayer metallo-dielectric hyperbolic metamaterials demonstrate SPR dispersion control, which can be combined with SPR imaging, to characterize high refractive index materials because of its exotic optical properties. Furthermore, nano-biophotonics could enable innovative energy conversion such as the increase of absorption and emission efficiency and the perfect absorption. Localized SPR using metal nanoparticles show highly enhanced absorption in solar energy harvesting. Three-dimensional hyperbolic metamaterial cavity nanostructure shows enhanced spontaneous emission. Recently ultrathin film perfect absorber is demonstrated with the film thickness is as low as ~1/50th of the operating wavelength using epsilon-near-zero (ENZ phenomena at the wavelength close to SPR. It is expected to provide a breakthrough in sensing and energy conversion applications using the exotic optical properties based on the nanophotonic technique.

  4. Ultra-high-speed optical serial-to-parallel data conversion by time-domain optical Fourier transformation in a silicon nanowire

    DEFF Research Database (Denmark)

    Mulvad, Hans Christian Hansen; Palushani, Evarist; Hu, Hao

    2011-01-01

    We demonstrate conversion from 64 × 10 Gbit/s optical timedivision multiplexed (OTDM) data to dense wavelength division multiplexed (DWDM) data with 25 GHz spacing. The conversion is achieved by time-domain optical Fourier transformation (OFT) based on four-wave mixing (FWM) in a 3.6 mm long...

  5. High-speed photonically assisted analog-to-digital conversion using a continuous wave multiwavelength source and phase modulation.

    Science.gov (United States)

    Bortnik, Bartosz J; Fetterman, Harold R

    2008-10-01

    A more simple photonically assisted analog-to-digital conversion system utilizing a cw multiwavelength source and phase modulation instead of a mode-locked laser is presented. The output of the cw multiwavelength source is launched into a dispersive device (such as a single-mode fiber). This fiber creates a pulse train, where the central wavelength of each pulse corresponds to a spectral line of the optical source. The pulses can then be either dispersed again to perform discrete wavelength time stretching or demultiplexed for continuous time analog-to-digital conversion. We experimentally demonstrate the operation of both time stretched and interleaved systems at 38 GHz. The potential of integrating this type of system on a monolithic chip is discussed.

  6. Skin dose rate conversion factors after contamination with radiopharmaceuticals: influence of contamination area, epidermal thickness and percutaneous absorption

    International Nuclear Information System (INIS)

    Covens, P; Berus, D; Caveliers, V; Struelens, L; Vanhavere, F; Verellen, D

    2013-01-01

    Skin contamination with radiopharmaceuticals can occur during biomedical research and daily nuclear medicine practice as a result of accidental spills, after contact with bodily fluids of patients or by inattentively touching contaminated materials. Skin dose assessment should be carried out by repeated quantification to map the course of the contamination together with the use of appropriate skin dose rate conversion factors. Contamination is generally characterised by local spots on the palmar surface of the hand and complete decontamination is difficult as a result of percutaneous absorption. This specific issue requires special consideration as to the skin dose rate conversion factors as a measure for the absorbed dose rate to the basal layer of the epidermis. In this work we used Monte Carlo simulations to study the influence of the contamination area, the epidermal thickness and the percutaneous absorption on the absorbed skin dose rate conversion factors for a set of 39 medical radionuclides. The results show that the absorbed dose to the basal layer of the epidermis can differ by up to two orders of magnitude from the operational quantity H p (0.07) when using an appropriate epidermal thickness in combination with the effect of percutaneous absorption. (paper)

  7. Conversion factor and uncertainty estimation for quantification of towed gamma-ray detector measurements in Tohoku coastal waters

    International Nuclear Information System (INIS)

    Ohnishi, S.; Thornton, B.; Kamada, S.; Hirao, Y.; Ura, T.; Odano, N.

    2016-01-01

    Factors to convert the count rate of a NaI(Tl) scintillation detector to the concentration of radioactive cesium in marine sediments are estimated for a towed gamma-ray detector system. The response of the detector against a unit concentration of radioactive cesium is calculated by Monte Carlo radiation transport simulation considering the vertical profile of radioactive material measured in core samples. The conversion factors are acquired by integrating the contribution of each layer and are normalized by the concentration in the surface sediment layer. At the same time, the uncertainty of the conversion factors are formulated and estimated. The combined standard uncertainty of the radioactive cesium concentration by the towed gamma-ray detector is around 25 percent. The values of uncertainty, often referred to as relative root mean squat errors in other works, between sediment core sampling measurements and towed detector measurements were 16 percent in the investigation made near the Abukuma River mouth and 5.2 percent in Sendai Bay, respectively. Most of the uncertainty is due to interpolation of the conversion factors between core samples and uncertainty of the detector's burial depth. The results of the towed measurements agree well with laboratory analysed sediment samples. Also, the concentrations of radioactive cesium at the intersection of each survey line are consistent. The consistency with sampling results and between different lines' transects demonstrate the availability and reproducibility of towed gamma-ray detector system.

  8. Conversion factor and uncertainty estimation for quantification of towed gamma-ray detector measurements in Tohoku coastal waters

    Energy Technology Data Exchange (ETDEWEB)

    Ohnishi, S., E-mail: ohnishi@nmri.go.jp [National Maritime Research Institute, 6-38-1, Shinkawa, Mitaka, Tokyo 181-0004 (Japan); Thornton, B. [Institute of Industrial Science, The University of Tokyo, 4-6-1, Komaba, Meguro-ku, Tokyo 153-8505 (Japan); Kamada, S.; Hirao, Y.; Ura, T.; Odano, N. [National Maritime Research Institute, 6-38-1, Shinkawa, Mitaka, Tokyo 181-0004 (Japan)

    2016-05-21

    Factors to convert the count rate of a NaI(Tl) scintillation detector to the concentration of radioactive cesium in marine sediments are estimated for a towed gamma-ray detector system. The response of the detector against a unit concentration of radioactive cesium is calculated by Monte Carlo radiation transport simulation considering the vertical profile of radioactive material measured in core samples. The conversion factors are acquired by integrating the contribution of each layer and are normalized by the concentration in the surface sediment layer. At the same time, the uncertainty of the conversion factors are formulated and estimated. The combined standard uncertainty of the radioactive cesium concentration by the towed gamma-ray detector is around 25 percent. The values of uncertainty, often referred to as relative root mean squat errors in other works, between sediment core sampling measurements and towed detector measurements were 16 percent in the investigation made near the Abukuma River mouth and 5.2 percent in Sendai Bay, respectively. Most of the uncertainty is due to interpolation of the conversion factors between core samples and uncertainty of the detector's burial depth. The results of the towed measurements agree well with laboratory analysed sediment samples. Also, the concentrations of radioactive cesium at the intersection of each survey line are consistent. The consistency with sampling results and between different lines' transects demonstrate the availability and reproducibility of towed gamma-ray detector system.

  9. Dual-drive Mach-Zehnder modulator-based reconfigurable and transparent spectral conversion for dense wavelength division multiplexing transmissions

    Science.gov (United States)

    Mao, Mingzhi; Qian, Chen; Cao, Bingyao; Zhang, Qianwu; Song, Yingxiong; Wang, Min

    2017-09-01

    A digital signal process enabled dual-drive Mach-Zehnder modulator (DD-MZM)-based spectral converter is proposed and extensively investigated to realize dynamically reconfigurable and high transparent spectral conversion. As another important innovation point of the paper, to optimize the converter performance, the optimum operation conditions of the proposed converter are deduced, statistically simulated, and experimentally verified. The optimum conditions supported-converter performances are verified by detail numerical simulations and experiments in intensity-modulation and direct-detection-based network in terms of frequency detuning range-dependent conversion efficiency, strict operation transparency for user signal characteristics, impact of parasitic components on the conversion performance, as well as the converted component waveform are almost nondistortion. It is also found that the converter has the high robustness to the input signal power, optical signal-to-noise ratio variations, extinction ratio, and driving signal frequency.

  10. Analysis of physical layer performance of data center with optical wavelength switches based on advanced modulation formats

    Science.gov (United States)

    Ahmad, Iftikhar; Chughtai, Mohsan Niaz

    2018-05-01

    In this paper the IRIS (Integrated Router Interconnected spectrally), an optical domain architecture for datacenter network is analyzed. The IRIS integrated with advanced modulation formats (M-QAM) and coherent optical receiver is analyzed. The channel impairments are compensated using the DSP algorithms following the coherent receiver. The proposed scheme allows N2 multiplexed wavelengths for N×N size. The performance of the N×N-IRIS switch with and without wavelength conversion is analyzed for different Baud rates over M-QAM modulation formats. The performance of the system is analyzed in terms of bit error rate (BER) vs OSNR curves.

  11. Temperature and current coefficients of lasing wavelength in tunable diode laser spectroscopy.

    Science.gov (United States)

    Fukuda, M; Mishima, T; Nakayama, N; Masuda, T

    2010-08-01

    The factors determining temperature and current coefficients of lasing wavelength are investigated and discussed under monitoring CO(2)-gas absorption spectra. The diffusion rate of Joule heating at the active layer to the surrounding region is observed by monitoring the change in the junction voltage, which is a function of temperature and the wavelength (frequency) deviation under sinusoidal current modulation. Based on the experimental results, the time interval of monitoring the wavelength after changing the ambient temperature or injected current (scanning rate) has to be constant at least to eliminate the monitoring error induced by the deviation of lasing wavelength, though the temperature and current coefficients of lasing wavelength differ with the rate.

  12. Coherent and incoherent (μ-, e-) conversion in nuclei

    International Nuclear Information System (INIS)

    Chiang, H.C.; Oset, E.; Kosmas, T.S.; Faessler, A.; Vergados, J.D.

    1993-01-01

    Coherent and incoherent (μ - , e - ) conversion in nuclei is studied within the framework of several theories which violate flavour lepton number. A useful approach is followed which allows a factorization of the conversion widths into nuclear factors and other factors which depend only on the elementary process. The nuclear factors are evaluated in a wide range of nuclei allowing simple calculations of the conversion rates throughout the periodic table for a given theory with a minimum of work in the elementary sector. The coherent conversion is found to dominate the process. The results obtained modify appreciable previous results in the literature, particularly in the incoherent process. (orig.)

  13. CRPS: A contingent hypothesis with prostaglandins as crucial conversion factor.

    Science.gov (United States)

    van der Veen, Phe

    2015-11-01

    CRPS is an acute pain disease expressed as chronic pain with a severe loss of tissue and function. CRPS usually occurs after minor injuries and then progresses in a way that is scarcely controllable, or completely uncontrollable. This article addresses the functional control mechanism of a biological organism, a comparison of techniques, and the way the negative feedback mechanisms fail in regulated feedback systems. The measurement and regulation system is controlled at the local, regional, and central levels in a biological system. Locally generated substances such as prostaglandins and hormones, as well as the central nervous system, play important roles in this process. Prostaglandins fulfil many conversion functions and are involved in vasoactive processes, pain, and inflammation. They play an intermediating role between the activity of the autonomic nervous system and local occurrences. The insufficiently explored conversion function of prostaglandins as a ubiquitously present cofactor may be related to the development of CRPS at sites which have had minor injuries in the past. Chronic Regional Pain Syndrome (CRPS) is a moderately prevalent disease, which occurs more frequently with age. Even though there are diseases known to have a precipitating effect on the aetiology of CRPS, for example Carpal tunnel syndrome, the mechanism of onset is unknown. The disease falls under the category of chronic pain, and seldom has an effective treatment based on scientific research. The economic and psychosocial aspects of the disease are substantial. CRPS is the final position of a positive feedback measurement and control system. Homoeostasis is directed by measurement and control processes. In electronics, a rapid conversion system, which quickly adapts to changing circumstances, superimposed with a delayed conversion system, which ensures a stable basis of homoeostasis. Measured changes are compensatorily controlled. An analogy is expected for a Complex Adaptive System

  14. Drivers of wetland conversion: a global meta-analysis.

    Science.gov (United States)

    van Asselen, Sanneke; Verburg, Peter H; Vermaat, Jan E; Janse, Jan H

    2013-01-01

    Meta-analysis of case studies has become an important tool for synthesizing case study findings in land change. Meta-analyses of deforestation, urbanization, desertification and change in shifting cultivation systems have been published. This present study adds to this literature, with an analysis of the proximate causes and underlying forces of wetland conversion at a global scale using two complementary approaches of systematic review. Firstly, a meta-analysis of 105 case-study papers describing wetland conversion was performed, showing that different combinations of multiple-factor proximate causes, and underlying forces, drive wetland conversion. Agricultural development has been the main proximate cause of wetland conversion, and economic growth and population density are the most frequently identified underlying forces. Secondly, to add a more quantitative component to the study, a logistic meta-regression analysis was performed to estimate the likelihood of wetland conversion worldwide, using globally-consistent biophysical and socioeconomic location factor maps. Significant factors explaining wetland conversion, in order of importance, are market influence, total wetland area (lower conversion probability), mean annual temperature and cropland or built-up area. The regression analyses results support the outcomes of the meta-analysis of the processes of conversion mentioned in the individual case studies. In other meta-analyses of land change, similar factors (e.g., agricultural development, population growth, market/economic factors) are also identified as important causes of various types of land change (e.g., deforestation, desertification). Meta-analysis helps to identify commonalities across the various local case studies and identify which variables may lead to individual cases to behave differently. The meta-regression provides maps indicating the likelihood of wetland conversion worldwide based on the location factors that have determined historic

  15. Towards a versatile active wavelength converter for all-optical networks based on quasi-phase matched intra-cavity difference-frequency generation.

    Science.gov (United States)

    Torregrosa, Adrián J; Maestre, Haroldo; Capmany, Juan

    2013-11-18

    The availability of reconfigurable all-optical wavelength converters for an efficient and flexible use of optical resources in WDM (wavelength division multiplexing) networks is still lacking at present. We propose and report preliminary results on a versatile active technique for multiple and tunable wavelength conversions in the 1500-1700 nm spectral region. The technique is based on combining broadband quasi-phase matched intra-cavity parametric single-pass difference-frequency generation close to degeneracy in a diode-pumped tunable laser. A periodically poled stoichiometric lithium tantalate crystal is used as the nonlinear medium, with a parametric pump wave generated in a continuous-wave self-injection locked Cr3+:LiCAF tunable laser operating at around 800 nm.

  16. High-fidelity frequency down-conversion of visible entangled photon pairs with superconducting single-photon detectors

    International Nuclear Information System (INIS)

    Ikuta, Rikizo; Kato, Hiroshi; Kusaka, Yoshiaki; Yamamoto, Takashi; Imoto, Nobuyuki; Miki, Shigehito; Yamashita, Taro; Terai, Hirotaka; Wang, Zhen; Fujiwara, Mikio; Sasaki, Masahide; Koashi, Masato

    2014-01-01

    We experimentally demonstrate a high-fidelity visible-to-telecommunicationwavelength conversion of a photon by using a solid-state-based difference frequency generation. In the experiment, one half of a pico-second visible entangled photon pair at 780 nm is converted to a 1522-nm photon. Using superconducting single-photon detectors with low dark count rates and small timing jitters, we observed a fidelity of 0.93±0.04 after the wavelength conversion

  17. Dose conversion factors and linear energy transfer for irradiation of thin blood layers with low-energy X rays

    International Nuclear Information System (INIS)

    Verhaegen, F.; Seuntjens, J.

    1994-01-01

    For irradiation of thin samples of biological material with low-energy X rays, conversion of measured air kerma, free in air to average absorbed dose to the sample is necessary. In the present paper, conversion factors from measured air kerma to average absorbed dose in thin blood samples are given for four low-energy X-ray qualities (14-50 kVp). These factors were obtained by Monte Carlo simulation of a practical sample holder. Data for different thicknesses of the blood and backing layer are presented. The conversion factors are found to depend strongly on the thicknesses of the blood layer and backing layer. In radiobiological work, knowledge of linear energy transfer (LET) values for the radiation quality used is often required. Track-averaged LET values for low-energy X rays are presented in this work. It is concluded that the thickness of the sample does not influence the LET value appreciably, indicating that for all radiobiological purposes this value can be regarded as a constant throughout the sample. Furthermore, the large difference between the LET value for a 50 kV spectrum found in this work and the value given in ICRU Report 16 is pointed out. 16 refs., 7 figs., 1 tab

  18. Mitigating of modal instabilities in linearly-polarized fiber amplifiers by shifting pump wavelength

    International Nuclear Information System (INIS)

    Tao, Rumao; Ma, Pengfei; Wang, Xiaolin; Zhou, Pu; Liu, Zejin

    2015-01-01

    We investigated the effect of pump wavelength on the modal instabilities (MI) in high-power linearly polarized Yb-doped fiber amplifiers. We built a novel semi-analytical model to determine the frequency coupling characteristics and power threshold of MI, which indicates promising MI suppression through pumping at an appropriate wavelength. By pumping at 915 nm, the threshold can be enhanced by a factor of 2.1 as compared to that pumped at 976 nm. Based on a high-power linearly polarized fiber amplifier platform, we studied the influence of pump wavelength experimentally. A maximal enhancement factor of 1.9 has been achieved when pumped at 915 nm, which agrees with the theoretical calculation and verified our theoretical model. Furthermore, we show that MI suppression by detuning the pump wavelength is weakened for fiber with a large core-to-cladding ratio. (paper)

  19. Influences of external factors on the energy conversion and productivity of Scenedesmus sp. in mass culture

    NARCIS (Netherlands)

    Wesselius, J.C.

    1973-01-01

    Experiments about the influence of external factors on the energy conversion in mass cultures of Scenedesmus are described in this thesis. Several types of culture vessels were used in the laboratory as well as in the open. Demonstration models of Miele washing

  20. Wavelength-stepped, actively mode-locked fiber laser based on wavelength-division-multiplexed optical delay lines

    Science.gov (United States)

    Lee, Eunjoo; Kim, Byoung Yoon

    2017-12-01

    We propose a new scheme for an actively mode-locked wavelength-swept fiber laser that produces a train of discretely wavelength-stepped pulses from a short fiber cavity. Pulses with different wavelengths are split and combined by standard wavelength division multiplexers with fiber delay lines. As a proof of concept, we demonstrate a laser using an erbium doped fiber amplifier and commercially available wavelength-division multiplexers with wavelength spacing of 0.8 nm. The results show simultaneous mode-locking at three different wavelengths. Laser output parameters in time domain, optical and radio frequency spectral domain, and the noise characteristics are presented. Suggestions for the improved design are discussed.

  1. Simple approach to three-color two-photon microscopy by a fiber-optic wavelength convertor.

    Science.gov (United States)

    Li, Kuen-Che; Huang, Lynn L H; Liang, Jhih-Hao; Chan, Ming-Che

    2016-11-01

    A simple approach to multi-color two-photon microscopy of the red, green, and blue fluorescent indicators was reported based on an ultra-compact 1.03-μm femtosecond laser and a nonlinear fiber. Inside the nonlinear fiber, the 1.03-μm laser pulses were simultaneously blue-shifted to 0.6~0.8 μm and red-shifted to 1.2~1.4 μm region by the Cherenkov radiation and fiber Raman gain effects. The wavelength-shifted 0.6~0.8 μm and 1.2~1.4 μm radiations were co-propagated with the residual non-converted 1.03-μm pulses inside the same nonlinear fiber to form a fiber-output three-color femtosecond source. The application of the multi-wavelength sources on multi-color two-photon fluorescence microscopy were also demonstrated. Overall, due to simple system configuration, convenient wavelength conversion, easy wavelength tunability within the entire 0.7~1.35 μm bio-penetration window and less requirement for high power and bulky light sources, the simple approach to multi-color two-photon microscopy could be widely applicable as an easily implemented and excellent research tool for future biomedical and possibly even clinical applications.

  2. Polarisation-preserving photon frequency conversion from a trapped-ion-compatible wavelength to the telecom C-band

    Science.gov (United States)

    Krutyanskiy, V.; Meraner, M.; Schupp, J.; Lanyon, B. P.

    2017-09-01

    We demonstrate polarisation-preserving frequency conversion of single-photon-level light at 854 nm, resonant with a trapped-ion transition and qubit, to the 1550-nm telecom C band. A total photon in / fiber-coupled photon out efficiency of ˜30% is achieved, for a free-running photon noise rate of ˜60 Hz. This performance would enable telecom conversion of 854 nm polarisation qubits, produced in existing trapped-ion systems, with a signal-to-noise ratio greater than 1. In combination with near-future trapped-ion systems, our converter would enable the observation of entanglement between an ion and a photon that has travelled more than 100 km in optical fiber: three orders of magnitude further than the state-of-the-art.

  3. Biosphere Dose Conversion Factors for Reasonably Maximally Exposed Individual and Average Member of Critical Group

    International Nuclear Information System (INIS)

    K. Montague

    2000-01-01

    The purpose of this calculation is to develop additional Biosphere Dose Conversion Factors (BDCFs) for a reasonably maximally exposed individual (RMEI) for the periods 10,000 years and 1,000,000 years after the repository closure. In addition, Biosphere Dose Conversion Factors for the average member of a critical group are calculated for those additional radionuclides postulated to reach the environment during the period after 10,000 years and up to 1,000,000 years. After the permanent closure of the repository, the engineered systems within the repository will eventually lose their abilities to contain radionuclide inventory, and the radionuclides will migrate through the geosphere and eventually enter the local water table moving toward inhabited areas. The primary release scenario is a groundwater well used for drinking water supply and irrigation, and this calculation takes these postulated releases and follows them through various pathways until they result in a dose to either a member of critical group or a reasonably maximally exposed individual. The pathways considered in this calculation include inhalation, ingestion, and direct exposure

  4. Textiles: Some technocal information and data II: Conversion factors, fibre properties, spinning limits, typical twist factors, weaving performannce and transfer printing temperatures.

    CSIR Research Space (South Africa)

    Hunter, L

    1978-07-01

    Full Text Available OF THE CSIR P.O. B O X 1 1 2 4 P O R T E L I Z A B E T H R E P U B L I C O F S O U T H A F R I C A WOL 47 ISBN 0 7988 1360 1 Contents INTRODUCTION ........................................................... Page .; ... 1 CONVERSION FACTORSAND... ........................................................................................ 118 REFERENCES TEXTILES: SOME TECHNICAL INFORMATION AND DATA 11: CONVERSION FACTORS, FIBRE PROPERTIES, SPINNING L I M I T S , T Y P I C A L T W I S T F A C T O R S , W E A V I N G PERFORMANCE A N D TRANSFER PRINTING TEMPERATURES 6.5, L...

  5. Short wavelength FELS

    International Nuclear Information System (INIS)

    Sheffield, R.L.

    1991-01-01

    The generation of coherent ultraviolet and shorter wavelength light is presently limited to synchrotron sources. The recent progress in the development of brighter electron beams enables the use of much lower energy electron rf linacs to reach short-wavelengths than previously considered possible. This paper will summarize the present results obtained with synchrotron sources, review proposed short- wavelength FEL designs and then present a new design which is capable of over an order of magnitude higher power to the extreme ultraviolet. 17 refs., 10 figs

  6. Short wavelength FELS

    Energy Technology Data Exchange (ETDEWEB)

    Sheffield, R.L.

    1991-01-01

    The generation of coherent ultraviolet and shorter wavelength light is presently limited to synchrotron sources. The recent progress in the development of brighter electron beams enables the use of much lower energy electron rf linacs to reach short-wavelengths than previously considered possible. This paper will summarize the present results obtained with synchrotron sources, review proposed short- wavelength FEL designs and then present a new design which is capable of over an order of magnitude higher power to the extreme ultraviolet. 17 refs., 10 figs.

  7. Dominant phonon polarization conversion across dimensionally mismatched interfaces: Carbon-nanotube-graphene junction

    Science.gov (United States)

    Shi, Jingjing; Lee, Jonghoon; Dong, Yalin; Roy, Ajit; Fisher, Timothy S.; Ruan, Xiulin

    2018-04-01

    Dimensionally mismatched interfaces are emerging for thermal management applications, but thermal transport physics remains poorly understood. Here we consider the carbon-nanotube-graphene junction, which is a dimensionally mismatched interface between one- and two-dimensional materials and is the building block for carbon-nanotube (CNT)-graphene three-dimensional networks. We predict the transmission function of individual phonon modes using the wave packet method; surprisingly, most incident phonon modes show predominantly polarization conversion behavior. For instance, longitudinal acoustic (LA) polarizations incident from CNTs transmit mainly into flexural transverse (ZA) polarizations in graphene. The frequency stays the same as the incident mode, indicating elastic transmission. Polarization conversion is more significant as the phonon wavelength increases. We attribute such unique phonon polarization conversion behavior to the dimensional mismatch across the interface, and it opens significantly new phonon transport channels as compared to existing theories where polarization conversion is neglected.

  8. A 12 GHz wavelength spacing multi-wavelength laser source for wireless communication systems

    Science.gov (United States)

    Peng, P. C.; Shiu, R. K.; Bitew, M. A.; Chang, T. L.; Lai, C. H.; Junior, J. I.

    2017-08-01

    This paper presents a multi-wavelength laser source with 12 GHz wavelength spacing based on a single distributed feedback laser. A light wave generated from the distributed feedback laser is fed into a frequency shifter loop consisting of 50:50 coupler, dual-parallel Mach-Zehnder modulator, optical amplifier, optical filter, and polarization controller. The frequency of the input wavelength is shifted and then re-injected into the frequency shifter loop. By re-injecting the shifted wavelengths multiple times, we have generated 84 optical carriers with 12 GHz wavelength spacing and stable output power. For each channel, two wavelengths are modulated by a wireless data using the phase modulator and transmitted through a 25 km single mode fiber. In contrast to previously developed schemes, the proposed laser source does not incur DC bias drift problem. Moreover, it is a good candidate for radio-over-fiber systems to support multiple users using a single distributed feedback laser.

  9. Underdense radiation sources: Moving towards longer wavelengths

    Energy Technology Data Exchange (ETDEWEB)

    Back, C.A.; Kilkenny, J.D. [General Atomics, San Diego, California (United States); Seely, J.F.; Weaver, J.L. [Naval Research Laboratory, Washington, DC (United States); Feldman, U. [Artep Inc., Ellicott City, MD (United States); Tommasini, R.; Glendinning, S.G.; Chung, H.K.; Rosen, M.; Lee, R.W.; Scott, H.A. [Lawrence Livermore National Laboratory, California (United States); Tillack, M. [U. C. San Diego, La Jolla, CA (United States)

    2006-06-15

    Underdense radiation sources have been developed to provide efficient laboratory multi-keV radiation sources for radiography and radiation hardening studies. In these plasmas laser absorption by inverse Bremsstrahlung leads to high x-ray conversion efficiency because of efficient ionization of the low density aerogel or gas targets. Now we performing experiments in the soft x-ray energy regime where the atomic physics models are much more complicated. In recent experiments at the NIKE laser, we have irradiated a Ti-doped SiO{sub 2} aerogel with up to 1650 J of 248 nm wavelength light. The absolute Ti L-shell emission in the 200-800 eV range is measured with a diagnostic that uses a transmission grating coupled to Si photodiodes. We will give an overview of the temporally-resolved absolutely calibrated spectra obtained over a range of conditions. (authors)

  10. Underdense radiation sources: Moving towards longer wavelengths

    International Nuclear Information System (INIS)

    Back, C.A.; Kilkenny, J.D.; Seely, J.F.; Weaver, J.L.; Feldman, U.; Tommasini, R.; Glendinning, S.G.; Chung, H.K.; Rosen, M.; Lee, R.W.; Scott, H.A.; Tillack, M.

    2006-01-01

    Underdense radiation sources have been developed to provide efficient laboratory multi-keV radiation sources for radiography and radiation hardening studies. In these plasmas laser absorption by inverse Bremsstrahlung leads to high x-ray conversion efficiency because of efficient ionization of the low density aerogel or gas targets. Now we performing experiments in the soft x-ray energy regime where the atomic physics models are much more complicated. In recent experiments at the NIKE laser, we have irradiated a Ti-doped SiO 2 aerogel with up to 1650 J of 248 nm wavelength light. The absolute Ti L-shell emission in the 200-800 eV range is measured with a diagnostic that uses a transmission grating coupled to Si photodiodes. We will give an overview of the temporally-resolved absolutely calibrated spectra obtained over a range of conditions. (authors)

  11. Application of a conversion factor to estimate the adenoma detection rate from the polyp detection rate.

    LENUS (Irish Health Repository)

    Francis, Dawn L

    2011-03-01

    The adenoma detection rate (ADR) is a quality benchmark for colonoscopy. Many practices find it difficult to determine the ADR because it requires a combination of endoscopic and histologic findings. It may be possible to apply a conversion factor to estimate the ADR from the polyp detection rate (PDR).

  12. WDM cross-connect cascade based on all-optical wavelength converters for routing and wavelength slot interchanging using a reduced number of internal wavelengths

    DEFF Research Database (Denmark)

    Pedersen, Rune Johan Skullerud; Mikkelsen, Benny; Jørgensen, Bo Foged

    1998-01-01

    interchanging can be used to create a robust and nonblocking OXC. However, for an OXC with n fiber inlets each carrying m wavelengths the OXC requires n×m internal wavelengths, which constrains the size of the cross-connect. In this paper we therefore propose and demonstrate an architecture that uses a reduced......Optical transport layers need rearrangeable wavelength-division multiplexing optical cross-connects (OXCs) to increase the capacity and flexibility of the network. It has previously been shown that a cross-connect based on all-optical wavelength converters for routing as well as wavelength slot...... set of internal wavelengths without sacrificing cross-connecting capabilities. By inserting a partly equipped OXC with the new architecture in a 10-Gbit/s re-circulating loop setup we demonstrate the possibility of cascading up to ten OXCs. Furthermore, we investigate the regenerating effect...

  13. The Thoron Issue: Monitoring Activities, Measuring Techniques and Dose Conversion Factors (invited paper)

    International Nuclear Information System (INIS)

    Nuccetelli, C.; Bochicchio, F.

    1998-01-01

    The health risk due to the presence of thoron indoors is usually neglected because of its generally low concentration in indoor environments, which is essentially caused by its short half-life. However, in certain not uncommon situations, such as when thorium-rich building materials are used, thoron ( 220 Rn) may represent a significant source of radioactive exposure. In recent years, renewed interest has led to more intensive monitoring of thoron gas and its decay products. A tentatively comprehensive summary of these measurement results and a review of the most innovative measurement techniques for 220 Rn are here presented. Finally, dose-exposure conversion factors currently used for thoron decay products are analysed, highlighting the poorer basis of such factors, when compared to those for radon. (author)

  14. Experimental verification of the air kerma to absorbed dose conversion factor Cw,u.

    Science.gov (United States)

    Mijnheer, B J; Wittkämper, F W; Aalbers, A H; van Dijk, E

    1987-01-01

    In a recently published code of practice for the dosimetry of high-energy photon beams, the absorbed dose to water is determined using an ionization chamber having an air kerma calibration factor and applying the air kerma to absorbed dose conversion factor Cw,u. The consistency of these Cw,u values has been determined for four commonly employed types of ionization chambers in photon beams with quality varying between 60Co gamma-rays and 25 MV X-rays. Using a graphite calorimeter, Cw,u has been determined for a graphite-walled ionization chamber (NE 2561) for the same qualities. The values of Cw,u determined with the calorimeter are within the experimental uncertainty equal to Cw,u values determined according to any of the recent dosimetry protocols.

  15. Enhanced UV light detection using a p-terphenyl wavelength shifter

    Science.gov (United States)

    Joosten, S.; Kaczanowicz, E.; Ungaro, M.; Rehfuss, M.; Johnston, K.; Meziani, Z.-E.

    2017-10-01

    UV-glass photomultiplier tubes (PMTs) have poor photon detection efficiency for wavelengths below 300 nm due to the opaqueness of the window material. Costly quartz PMTs could be used to enhance the efficiency below 300 nm. A less expensive solution that dramatically improves this efficiency is the application of a thin film of a p-terphenyl (PT) wavelength shifter on UV-glass PMTs. This improvement was quantified for Photonis XP4500B PMTs for wavelengths between 200 nm and 400 nm. The gain factor ranges up to 5 . 4 ± 0 . 5 at a wavelength of 215 nm, with a material load of 110 ± 10 μg /cm2 (894 nm). The wavelength shifter was found to be fully transparent for wavelengths greater than 300 nm. The resulting gain in detection efficiency, when used in a typical C̆erenkov counter, was estimated to be of the order of 40%. Consistent coating quality was assured by a rapid gain testing procedure using narrow-band UV LEDs. Based on these results, 200 Photonis XP4500B PMTs were treated with PT for the upgraded low-threshold C̆erenkov counter (LTCC) to be used in the CEBAF Large Acceptance Spectrometer upgraded detector (CLAS12) at the Thomas Jefferson National Accelerator Facility.

  16. Laser-assisted decontamination—A wavelength dependent study

    Science.gov (United States)

    Nilaya, J. Padma; Raote, Pallavi; Kumar, Aniruddha; Biswas, Dhruba J.

    2008-09-01

    We present here the experimental results on cleaning of radioactive dielectric particulates, loosely deposited on stainless steel, by coherent light of 1064 nm wavelength and its three harmonics occurring at 532 nm, 355 nm and 266 nm, derived from an Nd-YAG laser. For the initial few exposures, the decontamination factor has been found to be highest when exposed to 1064 nm radiation. With increasing number of exposures, however, the radiation with reducing wavelength assumes a more important role as a cleaning agent. The observation of almost no cleaning with 1064 nm and much reduced cleaning with its harmonics when the contamination is deposited on a transparent substrate confirms the dominant role played by metal substrate towards expelling the loose particulates from its surface.

  17. Fabrication of Up-Conversion Phosphor Films on Flexible Substrates Using a Nanostructured Organo-Silicon.

    Science.gov (United States)

    Jeon, Young-Sun; Kim, Tae-Un; Kim, Seon-Hoon; Lee, Young-Hwan; Choi, Pil-Son; Hwang, Kyu-Seog

    2018-03-01

    Up-conversion phosphors have attracted considerable attention because of their applications in solid-state lasers, optical communications, flat-panel displays, photovoltaic cells, and biological labels. Among them, NaYF4 is reported as one of the most efficient hosts for infrared to visible photon up-conversion of Yb3+ and Er3+ ions. However, a low-temperature method is required for industrial scale fabrication of photonic and optoelectronic devices on flexible organic substrates. In this study, hexagonal β-NaYF4: 3 mol% Yb3+, 3 mol% Er3+ up-conversion phosphor using Ca2+ was prepared by chemical solution method. Then, we synthesized a nanostructured organo-silicon compound from methyl tri-methoxysilane and 3-glycidoxy-propyl-trimethoxy-silane. The transmittance of the organo-silicon compound was found to be over 90% in the wavelength range of 400~1500 nm. Then we prepared a fluoride-based phosphor paste by mixing the organo-silicon compound with Na(Ca)YF4:Yb3+, Er3+. Subsequently, this paste was coated on polyethylene terephthalate, followed by heat-treatment at 120 °C. The visible emission of the infrared detection card was found to be at 655 nm and 661 nm an excitation wavelength of 980 nm.

  18. Experimental determination of relative light conversion factors of TLD-100 for protons with energies from 2.0 to 9.0 MeV

    International Nuclear Information System (INIS)

    Schmidt, P.; Fellinger, J.; Huebner, K.; Henniger, J.

    1985-01-01

    Relative light conversion factors (RLCF) for heavy charged particles (protons, deuterons, recoils) are needed for the calculation of the neutron sensitivity of thermoluminescent (TL) detectors. Such light conversion factors can be determined experimentally. A method is represented for the experimental determination of RLCF. The described experimental facility gives the possibility of irradiation of different luminophor samples with heavy charged particles and flux determination and particle spectrometry at the same time. For the determination of RLCF the doses are needed which are applicated at the irradiation with heavy charged particles and gamma radiation, respectively, and the according detector readings at the TL evaluation. The problems arising at the dose determination are discussed. With this experimental facility the RLCF for TLD-100 for protons were determined. The relative light conversion factors determined according to the light sum method as well as the peak height method are summarizinhly represented and discussed. Furthermore a comparison of the glow curves is made after gamma and proton irradiation

  19. Calculation of conversion factor of Kerma in the air for ambient dose equivalent in radiotherapy

    International Nuclear Information System (INIS)

    Lima, Marco Antonio Frota

    2000-03-01

    This work aims to estimate the average conversion factor of Kerma in air to H * (10) using photon beams coming from clinic linear accelerators, transmitted through concrete walls of a radiotherapic treatment room. The transmitted photon spectra by both 1 meter and 2 meters concrete walls, in an area of 40 x 40 cm 2 , were calculated when the primary beam impart in an angle of 0 deg. The (secondary) photon beams transmitted respectively by 0,5 meter, 1,0 meter, 1,0 meter and 2,0 meter concrete walls, after they scattered by an angle of 90 deg in a cylindric phantom inside the room, were also determined. Generally, 50 millions of histories were computed for each simulation made for the primary beam. For the 90 deg spread, the number of histories was 100 millions. The computational code used on this work was the MCNP4B. The most common clinic accelerators used on radiotheraphic treatments were used on this work CLINAC-4, CLINAC-6, CLINAC-18 and CLINAC-2500. From the spectra analysis obtained in this work, it was possible to dispose the conversion factor for realistic beams found in radiotherapeutic establishment. (author)

  20. Agility of Felix Regarding Wavelength and Micropulse Shape

    NARCIS (Netherlands)

    Bakker, R. J.; van der Geer, C. A. J.; Jaroszynski, D. A.; van der Meer, A. F. G.; Oepts, D.; van Amersfoort, P. W.; Anderegg, V.; van Son, P. C.

    1993-01-01

    The user-facility FELIX employs two FELs together covering the spectral range from 6.5 to 110 mum. Adjustment of the undulator strength permits wavelength tuning over a factor of two within two minutes while continuously providing several kilowatts of output power. As FELIX combines short electron

  1. Investigation of Alien Wavelength Quality in Live Multi-Domain, Multi-Vendor Link Using Advanced Simulation Tool

    DEFF Research Database (Denmark)

    Petersen, Martin Nordal; Nuijts, Roeland; Bjorn, Lars Lange

    2014-01-01

    This article presents an advanced optical model for simulation of alien wavelengths in multi-domain and multi-vendor dense wavelength-division multiplexing networks. The model aids optical network planners with a better understanding of the non-linear effects present in dense wavelength-division ......This article presents an advanced optical model for simulation of alien wavelengths in multi-domain and multi-vendor dense wavelength-division multiplexing networks. The model aids optical network planners with a better understanding of the non-linear effects present in dense wavelength......-division multiplexing systems and better utilization of alien wavelengths in future applications. The limiting physical effects for alien wavelengths are investigated in relation to power levels, channel spacing, and other factors. The simulation results are verified through experimental setup in live multi...

  2. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams

    International Nuclear Information System (INIS)

    Rosado, Paulo Henrique Goncalves

    2008-01-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm 3 Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with 133 Ba, 241 Am and 57 Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of conversion coefficients and

  3. Determination of conversion factors and efficiency for GM detectors used in measurements of surface pollution

    International Nuclear Information System (INIS)

    Ayala G, J.; Alvarez R, J.T.

    1999-01-01

    One of the objectives of the Radiation protection, is to observe with the National and as International standardization referring to the ICRP dose limitation system (ICRP 26, ICRP 60). In this work it was treated the problem corresponding about how to determine the conversion factor of cpm/mR/h and the absolute efficiency ε, for a Geiger-Muller equipment with thin window. This equipment is used for the beta particle detection. Thus the correct use of calibration factors and the procedures to convert cpm in Bq is expedited and also to apply the ISO procedure for to evaluate contaminated surfaces. (Author)

  4. Determining the spatial variability of wetland soil bulk density, organic matter, and the conversion factor between organic matter and organic carbon across coastal Louisiana, U.S.A.

    Science.gov (United States)

    Wang, Hongqing; Piazza, Sarai C.; Sharp, Leigh A.; Stagg, Camille L.; Couvillion, Brady R.; Steyer, Gregory D.; McGinnis, Thomas E.

    2016-01-01

    Soil bulk density (BD), soil organic matter (SOM) content, and a conversion factor between SOM and soil organic carbon (SOC) are often used in estimating SOC sequestration and storage. Spatial variability in BD, SOM, and the SOM–SOC conversion factor affects the ability to accurately estimate SOC sequestration, storage, and the benefits (e.g., land building area and vertical accretion) associated with wetland restoration efforts, such as marsh creation and sediment diversions. There are, however, only a few studies that have examined large-scale spatial variability in BD, SOM, and SOM–SOC conversion factors in coastal wetlands. In this study, soil cores, distributed across the entire coastal Louisiana (approximately 14,667 km2) were used to examine the regional-scale spatial variability in BD, SOM, and the SOM–SOC conversion factor. Soil cores for BD and SOM analyses were collected during 2006–09 from 331 spatially well-distributed sites in the Coastwide Reference Monitoring System network. Soil cores for the SOM–SOC conversion factor analysis were collected from 15 sites across coastal Louisiana during 2006–07. Results of a split-plot analysis of variance with incomplete block design indicated that BD and SOM varied significantly at a landscape level, defined by both hydrologic basins and vegetation types. Vertically, BD and SOM varied significantly among different vegetation types. The SOM–SOC conversion factor also varied significantly at the landscape level. This study provides critical information for the assessment of the role of coastal wetlands in large regional carbon budgets and the estimation of carbon credits from coastal restoration.

  5. Information for Consumers about Alternative Fuel Conversions

    Science.gov (United States)

    Here are some factors to be aware of if you are considering fuel conversion, including background information on fuel conversion, instructions for demonstrating compliance, and other related information.

  6. Electromagnetic wave energy conversion research

    Science.gov (United States)

    Bailey, R. L.; Callahan, P. S.

    1975-01-01

    Known electromagnetic wave absorbing structures found in nature were first studied for clues of how one might later design large area man-made radiant-electric converters. This led to the study of the electro-optics of insect dielectric antennae. Insights were achieved into how these antennae probably operate in the infrared 7-14um range. EWEC theoretical models and relevant cases were concisely formulated and justified for metal and dielectric absorber materials. Finding the electromagnetic field solutions to these models is a problem not yet solved. A rough estimate of losses in metal, solid dielectric, and hollow dielectric waveguides indicates future radiant-electric EWEC research should aim toward dielectric materials for maximum conversion efficiency. It was also found that the absorber bandwidth is a theoretical limitation on radiant-electric conversion efficiency. Ideally, the absorbers' wavelength would be centered on the irradiating spectrum and have the same bandwith as the irradiating wave. The EWEC concept appears to have a valid scientific basis, but considerable more research is needed before it is thoroughly understood, especially for the complex randomly polarized, wide band, phase incoherent spectrum of the sun. Specific recommended research areas are identified.

  7. Determination of photon conversion factors relating exposure and dose for several extremity phantom designs

    International Nuclear Information System (INIS)

    Roberson, P.L.; Eichner, F.N.; Reece, W.D.

    1986-09-01

    This report presents the results of measurements of dosimetric properties of simple extremity phantoms suitable for use in extremity dosimeter performance testing. Two sizes of phantoms were used in this study. One size represented the forearm or lower leg and the other size represented the finger or toe. For both phantom sizes, measurements were performed on solid plastic phantoms and on phantoms containing simulated bone material to determine the effect of backscattered radiations from the bone on the surface dose. Exposure-to-dose conversion factors (C/sub x/ factors) were determined for photon energies ranging from 16 to 1250 keV (average for 60 Co). The effect of the presence of a phantom was also measured for a 90 Sr/ 90 Y source. Significant differences in the measured C/sub x/ factors were found among the phantoms investigated. The factors for the finger-sized phantoms were uniformly less than for the arm-sized phantoms

  8. Full wave simulations of fast wave mode conversion and lower hybrid wave propagation in tokamaks

    DEFF Research Database (Denmark)

    Wright, J.C.; Bonoli, P.T.; Brambilla, M.

    2004-01-01

    Fast wave (FW) studies of mode conversion (MC) processes at the ion-ion hybrid layer in toroidal plasmas must capture the disparate scales of the FW and mode converted ion Bernstein and ion cyclotron waves. Correct modeling of the MC layer requires resolving wavelengths on the order of k...

  9. External-cavity high-power dual-wavelength tapered amplifier with tunable THz frequency difference

    DEFF Research Database (Denmark)

    Chi, Mingjun; Jensen, Ole Bjarlin; Petersen, Paul Michael

    2012-01-01

    A tunable 800 nm high-power dual-wavelength diode laser system with double-Littrow external-cavity feedback is demonstrated. The two wavelengths can be tuned individually, and the frequency difference of the two wavelengths is tunable from 0.5 to 5.0 THz. A maximum output power of 1.54 W is achie......A tunable 800 nm high-power dual-wavelength diode laser system with double-Littrow external-cavity feedback is demonstrated. The two wavelengths can be tuned individually, and the frequency difference of the two wavelengths is tunable from 0.5 to 5.0 THz. A maximum output power of 1.54 W...... is achieved with a frequency difference of 0.86 THz, the output power is higher than 1.3 W in the 5.0 THz range of frequency difference, and the amplified spontaneous emission intensity is more than 20 dB suppressed in the range of frequency difference. The beam quality factor M2 is 1.22±0.15 at an output...

  10. Semiconductor-based Multilayer Selective Solar Absorber for Unconcentrated Solar Thermal Energy Conversion.

    Science.gov (United States)

    Thomas, Nathan H; Chen, Zhen; Fan, Shanhui; Minnich, Austin J

    2017-07-13

    Solar thermal energy conversion has attracted substantial renewed interest due to its applications in industrial heating, air conditioning, and electricity generation. Achieving stagnation temperatures exceeding 200 °C, pertinent to these technologies, with unconcentrated sunlight requires spectrally selective absorbers with exceptionally low emissivity in the thermal wavelength range and high visible absorptivity for the solar spectrum. In this Communication, we report a semiconductor-based multilayer selective absorber that exploits the sharp drop in optical absorption at the bandgap energy to achieve a measured absorptance of 76% at solar wavelengths and a low emittance of approximately 5% at thermal wavelengths. In field tests, we obtain a peak temperature of 225 °C, comparable to that achieved with state-of-the-art selective surfaces. With straightforward optimization to improve solar absorption, our work shows the potential for unconcentrated solar thermal systems to reach stagnation temperatures exceeding 300 °C, thereby eliminating the need for solar concentrators for mid-temperature solar applications such as supplying process heat.

  11. Narrow band wavelength selective filter using grating assisted single ring resonator

    Energy Technology Data Exchange (ETDEWEB)

    Prabhathan, P., E-mail: PPrabhathan@ntu.edu.sg; Murukeshan, V. M. [Centre for Optical and Laser Engineering (COLE), School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 (Singapore)

    2014-09-15

    This paper illustrates a filter configuration which uses a single ring resonator of larger radius connected to a grating resonator at its drop port to achieve single wavelength selectivity and switching property with spectral features suitable for on-chip wavelength selection applications. The proposed configuration is expected to find applications in silicon photonics devices such as, on-chip external cavity lasers and multi analytic label-free biosensors. The grating resonator has been designed for a high Q-factor, high transmittivity, and minimum loss so that the wavelength selectivity of the device is improved. The proof-of-concept device has been demonstrated on a Silicon-on-Insulator (SOI) platform through electron beam lithography and Reactive Ion Etching (RIE) process. The transmission spectrum shows narrow band single wavelength selection and switching property with a high Free Spectral Range (FSR) ∼60 nm and side band rejection ratio >15 dB.

  12. Ten-watt level picosecond parametric mid-IR source broadly tunable in wavelength

    Science.gov (United States)

    Vyvlečka, Michal; Novák, Ondřej; Roškot, Lukáscaron; Smrž, Martin; Mužík, Jiří; Endo, Akira; Mocek, Tomáš

    2018-02-01

    Mid-IR wavelength range (between 2 and 8 μm) offers perspective applications, such as minimally-invasive neurosurgery, gas sensing, or plastic and polymer processing. Maturity of high average power near-IR lasers is beneficial for powerful mid-IR generation by optical parametric conversion. We utilize in-house developed Yb:YAG thin-disk laser of 100 W average power at 77 kHz repetition rate, wavelength of 1030 nm, and about 2 ps pulse width for pumping of a ten-watt level picosecond mid-IR source. Seed beam is obtained by optical parametric generation in a double-pass 10 mm long PPLN crystal pumped by a part of the fundamental near-IR beam. Tunability of the signal wavelength between 1.46 μm and 1.95 μm was achieved with power of several tens of miliwatts. Main part of the fundamental beam pumps an optical parametric amplification stage, which includes a walk-off compensating pair of 10 mm long KTP crystals. We already demonstrated the OPA output signal and idler beam tunability between 1.70-1.95 μm and 2.18-2.62 μm, respectively. The signal and idler beams were amplified up to 8.5 W and 5 W, respectively, at 42 W pump without evidence of strong saturation. Thus, increase in signal and idler output power is expected for pump power increase.

  13. Transcatheter Arterial Embolization for Primary Postpartum Hemorrhage: Predictive Factors of Need for Embolic Material Conversion of Gelatin Sponge Particles to N-Butyl Cyanoacrylate

    Energy Technology Data Exchange (ETDEWEB)

    Tanahashi, Yukichi; Goshima, Satoshi, E-mail: gossy@par.odn.ne.jp [Gifu University Hospital, Department of Radiology (Japan); Kondo, Hiroshi [Teikyo University School of Medicine, Department of Radiology (Japan); Ando, Tomohiro; Noda, Yoshifumi; Kawada, Hiroshi; Kawai, Nobuyuki [Gifu University Hospital, Department of Radiology (Japan); Kotoku, Junichi [Teikyo University School of Medicine, Department of Radiological Technology, Faculty of Medical Technology (Japan); Furui, Shigeru [Teikyo University School of Medicine, Department of Radiology (Japan); Matsuo, Masayuki [Gifu University Hospital, Department of Radiology (Japan)

    2017-02-15

    PurposeTo identify predictive factors for embolic material conversion to N-butyl cyanoacrylate (NBCA) for the treatment of primary postpartum hemorrhage (PPH) after failed transcatheter arterial embolization (TAE) using gelatin sponge (GS).Materials and MethodsInstitutional review board approval was obtained. We retrospectively studied 62 consecutive women with primary PPH who underwent TAE between January 2006 and March 2015. Five of them were excluded for the following: cardiopulmonary arrest at arrival (n = 1), uterine inversion (n = 1), and hysterectomy after TAE (n = 3). Remaining 57 women (age range, 21–43 years; mean, 32.6 years) comprised study population. TAE was initially performed using GS in all cases and then converted to NBCA after two embolizations using GS with persistent hemodynamic instability or vaginal bleeding. The patients’ background, uterine height, vital signs, laboratory tests, disseminated intravascular coagulation score, and details of procedure were reviewed. Univariate and multivariate analyses were performed to determine factors related to embolic material conversion.ResultsTechnical success rate was 100%. Fourteen patients (25%) needed embolic material conversion to NBCA. Univariate analysis showed that uterine height, systolic blood pressure (sBP), and hemoglobin level were significantly related to embolic material conversion to NBCA (P = 0.029, 0.030, and 0.042). Logistic regression analysis showed that uterine height (odds ratio, 1.37; P = 0.025) and sBP (odds ratio, 0.96; P = 0.003) were associated with embolic material conversion to NBCA.ConclusionUterine height and sBP can be predictive factors for embolic material conversion to NBCA for the treatment of PPH.Level of EvidenceLevel 4, Case Control Study.

  14. Transcatheter Arterial Embolization for Primary Postpartum Hemorrhage: Predictive Factors of Need for Embolic Material Conversion of Gelatin Sponge Particles to N-Butyl Cyanoacrylate

    International Nuclear Information System (INIS)

    Tanahashi, Yukichi; Goshima, Satoshi; Kondo, Hiroshi; Ando, Tomohiro; Noda, Yoshifumi; Kawada, Hiroshi; Kawai, Nobuyuki; Kotoku, Junichi; Furui, Shigeru; Matsuo, Masayuki

    2017-01-01

    PurposeTo identify predictive factors for embolic material conversion to N-butyl cyanoacrylate (NBCA) for the treatment of primary postpartum hemorrhage (PPH) after failed transcatheter arterial embolization (TAE) using gelatin sponge (GS).Materials and MethodsInstitutional review board approval was obtained. We retrospectively studied 62 consecutive women with primary PPH who underwent TAE between January 2006 and March 2015. Five of them were excluded for the following: cardiopulmonary arrest at arrival (n = 1), uterine inversion (n = 1), and hysterectomy after TAE (n = 3). Remaining 57 women (age range, 21–43 years; mean, 32.6 years) comprised study population. TAE was initially performed using GS in all cases and then converted to NBCA after two embolizations using GS with persistent hemodynamic instability or vaginal bleeding. The patients’ background, uterine height, vital signs, laboratory tests, disseminated intravascular coagulation score, and details of procedure were reviewed. Univariate and multivariate analyses were performed to determine factors related to embolic material conversion.ResultsTechnical success rate was 100%. Fourteen patients (25%) needed embolic material conversion to NBCA. Univariate analysis showed that uterine height, systolic blood pressure (sBP), and hemoglobin level were significantly related to embolic material conversion to NBCA (P = 0.029, 0.030, and 0.042). Logistic regression analysis showed that uterine height (odds ratio, 1.37; P = 0.025) and sBP (odds ratio, 0.96; P = 0.003) were associated with embolic material conversion to NBCA.ConclusionUterine height and sBP can be predictive factors for embolic material conversion to NBCA for the treatment of PPH.Level of EvidenceLevel 4, Case Control Study

  15. Wavelength dependent measurement of extinction in an extended-face crystal of zinc selenide

    International Nuclear Information System (INIS)

    Stevenson, A.W.; Barnea, Z.

    1982-01-01

    The effect of extinction on Bijvoet ratios is demonstrated. It is suggested that an observed anomaly in the wavelength dependence of ZnSe Bijvoet ratios is due to the Borrmann effect. It is shown that wavelength dependent studies of extinction may be used to obtain extinction parameters from relative intensity measurements without resorting to a refined scale factor

  16. Evaluation of conversion relationships for impression creep test at elevated temperatures

    International Nuclear Information System (INIS)

    Hyde, T.H.; Sun, W.

    2009-01-01

    This paper contains some results related to the evaluation of the conversion relationships between impression creep test data and conventional uniaxial creep test date, for determining the secondary creep properties at elevated temperature. Some important aspects, including conversion factors, specimen dimensions, typical test results and validity of the test technique etc are briefly reviewed. The method used to determine the conversion factors is based on a reference stress approach using the results of finite element (FE) analyses; this is described in the paper. The conversion factors (reference parameters) obtained from 2-dimensional (2D) and 3-dimensional (3D) FE analyses are compared and the effects of specimen geometry, on the conversion relationships, are assessed. The recommendations on the use of these conversion factors, in practical impression creep testing, are given. Proposals for future exploitation of the technique are addressed.

  17. Bleaching of the thermoluminescence of feldspars by selected wavelengths present in sunlight

    International Nuclear Information System (INIS)

    Robertson, G.B.; Prescott, J.R.; Hutton, J.T.

    1993-01-01

    Feldspars occur in many sediments, and dating them by thermoluminescence (TL) requires a knowledge of how efficiently sunlight bleaches these minerals. The relative bleaching efficiencies of various wavelengths have been investigated for four alkali feldspars and an oligoclase, using the natural TL of the samples and the artificial TL induced by laboratory irradiation, bleached by wavelengths in the range 322-550 nm. Ultraviolet wavelengths are more efficient than the longer wavelengths at bleaching all the glow-curve peaks and are responsible for most of the phototransfer from high-temperature peaks to low-temperature peaks. Some feldspars show an initial increase in TL intensity with bleaching. Two sanidines of similar bulk composition but different TL glow curves show different dependences on bleaching wavelength. In a sodic sanidine with a dominant 240 o C peak the energy required to bleach to 50% was a thousand times greater at 550 nm than at 322 nm. In contrast, another sanidine with a complex glow curve between 150 and 450 o C showed a much slower change in the 330 o C peak with wavelength - a factor of 10 between 322 and 550 nm - with a region between 400 and 500 nm which was almost independent of wavelength. This behaviour is explained by competing mechanisms of phototransfer and bleaching which depend on wavelength in different ways. (author)

  18. The knowledge conversion SECI process as innovation indicator analysis factor

    OpenAIRE

    Silva, Elaine da [UNESP; Valentim, Marta Lígia Pomim [UNESP

    2013-01-01

    It highlights the innovation importance in the current society and presents innovation indicators applied in 125 countries. We made an analysis in the 80 variables distributed through seven GII pillars, trying to identify the direct, indirect or null incidences of the knowledge conversion way described by the SECI Process. The researched revealed the fact that knowledge management, in this case specifically the knowledge conversion SECI Process, is present in the variables that, according to ...

  19. Preoperative Risk Factors for Conversion of Laparoscopic Cholecystectomy to Open Surgery - A Systematic Review and Meta-Analysis of Observational Studies

    DEFF Research Database (Denmark)

    Rothman, Josephine Philip; Burcharth, Jakob; Pommergaard, Hans-Christian

    2016-01-01

    were suitable for 7 meta-analyses on age, gender, body mass index, previous abdominal surgery, severity of disease, white blood cell count, and gallbladder wall thickness. CONCLUSIONS: A gallbladder wall thicker than 4-5 mm, a contracted gallbladder, age above 60 or 65, male gender, and acute...... cholecystitis were risk factors for the conversion of laparoscopic cholecystectomy to open surgery. Furthermore, there was no association between diabetes mellitus or white blood cell count and conversion to open surgery....

  20. Gene array analysis of neural crest cells identifies transcription factors necessary for direct conversion of embryonic fibroblasts into neural crest cells

    Directory of Open Access Journals (Sweden)

    Tsutomu Motohashi

    2016-03-01

    Full Text Available Neural crest cells (NC cells are multipotent cells that emerge from the edge of the neural folds and migrate throughout the developing embryo. Although the gene regulatory network for generation of NC cells has been elucidated in detail, it has not been revealed which of the factors in the network are pivotal to directing NC identity. In this study we analyzed the gene expression profile of a pure NC subpopulation isolated from Sox10-IRES-Venus mice and investigated whether these genes played a key role in the direct conversion of Sox10-IRES-Venus mouse embryonic fibroblasts (MEFs into NC cells. The comparative molecular profiles of NC cells and neural tube cells in 9.5-day embryos revealed genes including transcription factors selectively expressed in developing trunk NC cells. Among 25 NC cell-specific transcription factor genes tested, SOX10 and SOX9 were capable of converting MEFs into SOX10-positive (SOX10+ cells. The SOX10+ cells were then shown to differentiate into neurons, glial cells, smooth muscle cells, adipocytes and osteoblasts. These SOX10+ cells also showed limited self-renewal ability, suggesting that SOX10 and SOX9 directly converted MEFs into NC cells. Conversely, the remaining transcription factors, including well-known NC cell specifiers, were unable to convert MEFs into SOX10+ NC cells. These results suggest that SOX10 and SOX9 are the key factors necessary for the direct conversion of MEFs into NC cells.

  1. Assessment of independent risk factors of conversion into psychosis in the ultra-high risk state group of patients

    Directory of Open Access Journals (Sweden)

    Marta Gawłowska

    2010-12-01

    Full Text Available Background: The aim of this study was the independent psychosis risk factors assessment in a group of subjects fulfilling the criteria of at risk mental state, under specialist outpatient psychiatric care. Participants: Seventy-one patients – 33 women and 38 men, were involved into this study, aged on average 17.34, all under psychiatric care. The patients were recruited into the study in the sequence of their outpatient clinic admission. The criterion to be included into the study was the diagnosis of ultra-high risk state (UHRS – defined according to the Australian research group principles. Subsequently, the patients were divided into subgroups according to the clinical features of their mental state. Method: The author’s demographic questionnaire was applied in the study. Information regarding the family history of psychosis was obtained from patients and/or their relatives or carers. The patients’ mental state was assessed monthly – according to the presence of psychotic symptoms, change of their incidence and duration, presence of depressive symptoms or aggressive behaviour (measured by a three-level scale. On the basis of the obtained information, we evaluated: 1 conversion into psychosis time – measured from diagnosing of UHRS to the development of full-symptom psychosis, 2 therapeutic methods used (psychotherapy, pharmacotherapy or both, 3 use of psychoactive substances after being diagnosed with UHRS, 4 presence of serious life stressors (the patients’ subjective estimation – during the six-month period preceding the conversion into psychosis. Results: 1 In the UHRS group of patients, staying under professional outpatient psychiatric care, the use of marijuana was an independent risk factor of conversion into psychosis. 2 In the investigated group of patients with at risk mental state we did not find any correlation between modulating factors (including: therapeutic methods used, depressive symptoms, aggression or

  2. Broadband multi-wavelength Brillouin lasers with an operating wavelength range of 1500–1600 nm generated by four-wave mixing in a dual wavelength Brillouin fiber laser cavity

    Science.gov (United States)

    Li, Q.; Jia, Z. X.; Weng, H. Z.; Li, Z. R.; Yang, Y. D.; Xiao, J. L.; Chen, S. W.; Huang, Y. Z.; Qin, W. P.; Qin, G. S.

    2018-05-01

    We demonstrate broadband multi-wavelength Brillouin lasers with an operating wavelength range of 1500–1600 nm and a frequency separation of ~9.28 GHz generated by four-wave mixing in a dual wavelength Brillouin fiber laser cavity. By using one continuous-wave laser as the pump source, multi-wavelength Brillouin lasers with an operating wavelength range of 1554–1574 nm were generated via cascaded Brillouin scattering and four-wave mixing. Interestingly, when pumped by two continuous-wave lasers with an appropriate frequency separation, the operating wavelength range of the multi-wavelength Brillouin lasers was increased to 1500–1600 nm due to cavity-enhanced cascaded four-wave mixing among the frequency components generated by two pump lasers in the dual wavelength Brillouin laser cavity.

  3. Models of radionuclide distribution in the biosphere for radioactive waste storage safety assessment, collection of data and calculation of the biosphere dose conversion factors. Research report

    International Nuclear Information System (INIS)

    Landa, Jiri

    2008-12-01

    The core of the report is structured as follows: The biosphere dose conversion factor (BDCF); Foreign approaches (Sweden - SKB, USA - YMP, BIOPROTA); Definition and conversion factors for activity; Effective dose rate calculation (ingestion, inhalation, external irradiation); Analysis of the activity of the surface compartment, i.e. soil; Basic conceptual models of ecosystems; BDCF calculation/determination; and Systemization of the literature. (P.A.)

  4. Ecosystem specific dose conversion factors for Aberg, Beberg and Ceberg

    International Nuclear Information System (INIS)

    Nordlinder, S.; Bergstroem, U.; Mathiasson, Lena

    1999-12-01

    The aim of this study was to calculate ecosystem specific dose conversion factors (EDFs) for three hypothetical sites, Aberg, Beberg and Ceberg, used in the safety analysis SR 97. The EDFs can, in combination with calculated releases of radionuclides from the geosphere, be used to illustrate relative differences in doses to the most exposed individual due to accidental leakage of radionuclides from a deep repository for spent nuclear fuel. Maps of the three sites were studied and subdivided into areas, which were characterised according to an earlier developed module system. For each of the identified modules, ecosystem transport and exposure model calculations were performed for release of 1 Bq per year during 10 000 years. 44 radionuclides contained within a deep repository for spent nuclear fuel were considered. A preliminary comparison of the EDFs for the three sites showed that the highest relative doses can be expected in Ceberg due to the high frequency of peat bog modules

  5. Multi-metal, Multi-wavelength Surface-Enhanced Raman Spectroscopy Detection of Neurotransmitters.

    Science.gov (United States)

    Moody, Amber S; Sharma, Bhavya

    2018-04-05

    The development of a sensor for the rapid and sensitive detection of neurotransmitters could provide a pathway for the diagnosis of neurological diseases, leading to the discovery of more effective treatment methods. We investigate the use of surface enhanced Raman spectroscopy (SERS) based sensors for the rapid detection of melatonin, serotonin, glutamate, dopamine, GABA, norepinephrine, and epinephrine. Previous studies have demonstrated SERS detection of neurotransmitters; however, there has been no comprehensive study on the effect of the metal used as the SERS substrate or the excitation wavelength used for detection. Here, we present the detection of 7 neurotransmitters using both silver and gold nanoparticles at excitation wavelengths of 532, 633, and 785 nm. Over the range of wavelengths investigated, the SERS enhancement on the silver and gold nanoparticles varies, with an average enhancement factor of 10 5 -10 6 . The maximum SERS enhancement occurs at an excitation wavelength of 785 nm for the gold nanoparticles and at 633 nm for the silver nanoparticles.

  6. Experimental investigation of linear mode conversion in laser-produced plasmas

    International Nuclear Information System (INIS)

    Maaswinkel, A.G.M.

    1980-12-01

    In this work absorption mechanisms are investigated in hot dense plasmas produced by intense laser irradiation of planar targets. Central in this investigation stands the absorption by linear mode conversion; this process occurs in inhomogeneous plasmas if the electric field vector of the incident EM-wave has a component parallel to the density gradient; this causes electrostatic oscillations at the critical density (where ωsub(p)sub(e) = ω). In addition, absorption of the laser light by inverse bremsstrahlung is investigated. The absorption is determined by the reflection of the laser light from the plasma. To this aim optical diagnostics are used. The reflection into 4π sr is measured with an Ulbricht sphere, also the reflection in specular (geometric) direction is recorded. The absorption mechanisms have been isolated by variation of the polarization of the beam and the angle of incidence to the target. An essential part of the work has been the frequency up-conversion of the laser beam by nonlinear crystals; in this way the wavelength-dependence of the absorption in the plasma has been investigated at wavelengths 1.06 μm, 0.53 μm and 0.26 μm; the pulse duration in the experiments was 30 ps, the maximum irradiation on target was 10 14 W/cm 2 . (orig./HT)

  7. Disruptive Event Biosphere Doser Conversion Factor Analysis

    Energy Technology Data Exchange (ETDEWEB)

    M. Wasiolek

    2000-12-28

    The purpose of this report was to document the process leading to, and the results of, development of radionuclide-, exposure scenario-, and ash thickness-specific Biosphere Dose Conversion Factors (BDCFs) for the postulated postclosure extrusive igneous event (volcanic eruption) at Yucca Mountain. BDCF calculations were done for seventeen radionuclides. The selection of radionuclides included those that may be significant dose contributors during the compliance period of up to 10,000 years, as well as radionuclides of importance for up to 1 million years postclosure. The approach documented in this report takes into account human exposure during three different phases at the time of, and after, volcanic eruption. Calculations of disruptive event BDCFs used the GENII-S computer code in a series of probabilistic realizations to propagate the uncertainties of input parameters into the output. The pathway analysis included consideration of different exposure pathway's contribution to the BDCFs. BDCFs for volcanic eruption, when combined with the concentration of radioactivity deposited by eruption on the soil surface, allow calculation of potential radiation doses to the receptor of interest. Calculation of radioactivity deposition is outside the scope of this report and so is the transport of contaminated ash from the volcano to the location of the receptor. The integration of the biosphere modeling results (BDCFs) with the outcomes of the other component models is accomplished in the Total System Performance Assessment (TSPA), in which doses are calculated to the receptor of interest from radionuclides postulated to be released to the environment from the potential repository at Yucca Mountain.

  8. Nominal Performance Biosphere Dose Conversion Factor Analysis

    International Nuclear Information System (INIS)

    Wasiolek, M.

    2000-01-01

    The purpose of this report was to document the process leading to development of the Biosphere Dose Conversion Factors (BDCFs) for the postclosure nominal performance of the potential repository at Yucca Mountain. BDCF calculations concerned twenty-four radionuclides. This selection included sixteen radionuclides that may be significant nominal performance dose contributors during the compliance period of up to 10,000 years, five additional radionuclides of importance for up to 1 million years postclosure, and three relatively short-lived radionuclides important for the human intrusion scenario. Consideration of radionuclide buildup in soil caused by previous irrigation with contaminated groundwater was taken into account in the BDCF development. The effect of climate evolution, from the current arid conditions to a wetter and cooler climate, on the BDCF values was evaluated. The analysis included consideration of different exposure pathway's contribution to the BDCFs. Calculations of nominal performance BDCFs used the GENII-S computer code in a series of probabilistic realizations to propagate the uncertainties of input parameters into the output. BDCFs for the nominal performance, when combined with the concentrations of radionuclides in groundwater allow calculation of potential radiation doses to the receptor of interest. Calculated estimates of radionuclide concentration in groundwater result from the saturated zone modeling. The integration of the biosphere modeling results (BDCFs) with the outcomes of the other component models is accomplished in the Total System Performance Assessment (TSPA) to calculate doses to the receptor of interest from radionuclides postulated to be released to the environment from the potential repository at Yucca Mountain

  9. Biomass conversion and expansion factors are afected by thinning

    Directory of Open Access Journals (Sweden)

    Teresa Duque Enes

    2014-12-01

    Full Text Available Aim of the study: The objective of this paper is to investigate the use of Biomass Conversion and Expansion Factors (BCEFs in maritime pine (Pinus pinaster Ait. stands subjected to thinning.Area of the study: The study area refers to different ecosystems of maritime pine stands inNorthern Portugal.Material and methods: The study is supported by time data series and cross sectional data collected in permanent plots established in the North of Portugal. An assessment of BCEF values for the aboveground compartments and for total was completed for each studied stand. Identification of key variables affecting the value of the BCEFs in time and with thinning was conducted using correlation analysis. Predictive models for estimation of the BCEFs values in time and after thinning were developed using nonlinear regression analysis.Research highlights: For periods of undisturbed growth, the results show an allometric relationship between the BCEFs, the dominant height and the mean diameter. Management practices such as thinning also influence the factors. Estimates of the ratio change before and after thinning depend on thinning severity and thinning type. The developed models allow estimating the biomass of the stands, for the aboveground compartments and for total, based on information of stand characteristics and of thinning descriptors. These estimates can be used to assess the forest dry wood stocks to be used for pulp, bioenergy or other purposes, as well as the biomass quantification to support the evaluation of the net primary productivity.Keywords: carbon; softwood; thinning; volume; wood energy; maritime pine.

  10. Terahertz imaging of sub-wavelength particles with Zenneck surface waves

    Czech Academy of Sciences Publication Activity Database

    Navarro-Cia, M.; Natrella, M.; Dominec, Filip; Delagnes, J.C.; Kužel, Petr; Mounaix, P.; Graham, C.; Renaud, C.C.; Seeds, A.J.; Mitrofanov, O.

    2013-01-01

    Roč. 103, č. 22 (2013), "221103-1"-"221103-5" ISSN 0003-6951 Institutional support: RVO:68378271 Keywords : terahertz * near-field * Zenneck plasmon * sub-wavelength * imaging Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 3.515, year: 2013

  11. All-fiber femtosecond Cherenkov laser at visible wavelengths

    DEFF Research Database (Denmark)

    Liu, Xiaomin; Lægsgaard, Jesper; Møller, Uffe Visbech

    2013-01-01

    -matching condition [1]. The resonant ultrafast wave conversion via the fiber-optic CR mechanism is instrumental for applications in biophotonics such as bio-imaging and microscopy [2]. In this work, we demonstrate a highly-stable all-fiber, fully monolithic CR system based on an Yb-fiber femtosecond laser, producing...... to be as low as -103 dBc/Hz. This is 2 orders of magnitudes lower noise as compared to spectrally-sliced supercontinuum, which is the current standard of ultrafast fiber-optic generation at visible wavelength. The layout of the laser system is shown in Fig. 1(a). The system consists of two parts: an all-fiber......Fiber-optic Cherenkov radiation (CR), also known as dispersive wave generation or non-solitonic radiation, is produced in small-core photonic crystal fibers (PCF) when a soliton perturbed by fiber higher-order dispersion co-propagates with a dispersive wave fulfilling a certain phase...

  12. Multichannel spectral mode of the ALOHA up-conversion interferometer

    Science.gov (United States)

    Lehmann, L.; Darré, P.; Boulogne, H.; Delage, L.; Grossard, L.; Reynaud, F.

    2018-06-01

    In this paper, we propose a multichannel spectral configuration of the Astronomical Light Optical Hybrid Analysis (ALOHA) instrument dedicated to high-resolution imaging. A frequency conversion process is implemented in each arm of an interferometer to transfer the astronomical light to a shorter wavelength domain. Exploiting the spectral selectivity of this non-linear optical process, we propose to use a set of independent pump lasers in order to simultaneously study multiple spectral channels. This principle is experimentally demonstrated with a dual-channel configuration as a proof-of-principle.

  13. ZnTe Semiconductor-Polymer Gel Composited Electrolyte for Conversion of Solar Energy

    Directory of Open Access Journals (Sweden)

    Wonchai Promnopas

    2014-01-01

    Full Text Available Nanostructured cubic p-type ZnTe for dye sensitized solar cells (DSSCs was synthesized from 1 : 1 molar ratio of Zn : Te by 600 W and 900 W microwave plasma for 30 min. In this research, their green emissions were detected at the same wavelengths of 563 nm, the energy gap (Eg at 2.24 eV, and three Raman shifts at 205, 410, and 620 cm−1. The nanocomposited electrolyte of quasisolid state ZnO-DSSCs was in correlation with the increase in the JSC, VOC, fill factor (ff, and efficiency (η by increasing the wt% of ZnTe-GPE (gel polymer electrolyte to an optimum value and decreased afterwards. The optimal ZnO-DSSC performance was achieved for 0.20 wt% ZnTe-GPE with the highest photoelectronic energy conversion efficiency at 174.7% with respect to that of the GPE without doping of p-type ZnTe.

  14. Time to sputum conversion in smear positive pulmonary TB patients on category I DOTS and factors delaying it.

    Science.gov (United States)

    Parikh, Raunak; Nataraj, Gita; Kanade, Swapna; Khatri, Vijay; Mehta, Preeti

    2012-08-01

    Sputum smear positive pulmonary tuberculosis patients expel infectious viable bacilli for a period following commencement of treatment. Patients on Directly Observed Treatment Shortcourse (DOTS) receive intermittent therapy with multidrug regimen. To determine the time to sputum smear and culture conversion following initiation of DOTS treatment and study the factors that influence it. A prospective study was undertaken at a tertiary care teaching hospital in Mumbai over a one year period on a cohort of 71 sputum smear positive patients on Category I DOTS treatment. Patients were followed up weekly for upto 20 weeks or until they underwent smear and culture conversion whichever was earlier. At each follow up, specimens were collected and processed for microscopy and culture using standard protocol. 60/71 [84.55%] patients completed the study. 56/60 [93.3%] patients underwent sputum smear and culture conversion. The median time to smear and culture conversion was end of 5th week [day 35] and 6 1/2 weeks [day 45] respectively. Univariate and stepwise regression analysis showed that patients who had cavitatory disease, high pretreatment smear grade and a past history of tuberculosis were more likely to undergo delayed or nonconversion [P culture conversion under DOTS is similar to previous antituberculosis regimens. Since viable bacilli continue to be expelled for upto two months, infection control measures should be maintained for such time. Patients with cavitatory disease, high pretreatment smear grade or a past history of tuberculosis need to be monitored more closely.

  15. Highly accurate Michelson type wavelength meter that uses a rubidium stabilized 1560 nm diode laser as a wavelength reference

    International Nuclear Information System (INIS)

    Masuda, Shin; Kanoh, Eiji; Irisawa, Akiyoshi; Niki, Shoji

    2009-01-01

    We investigated the accuracy limitation of a wavelength meter installed in a vacuum chamber to enable us to develop a highly accurate meter based on a Michelson interferometer in 1550 nm optical communication bands. We found that an error of parts per million order could not be avoided using famous wavelength compensation equations. Chromatic dispersion of the refractive index in air can almost be disregarded when a 1560 nm wavelength produced by a rubidium (Rb) stabilized distributed feedback (DFB) diode laser is used as a reference wavelength. We describe a novel dual-wavelength self-calibration scheme that maintains high accuracy of the wavelength meter. The method uses the fundamental and second-harmonic wavelengths of an Rb-stabilized DFB diode laser. Consequently, a highly accurate Michelson type wavelength meter with an absolute accuracy of 5x10 -8 (10 MHz, 0.08 pm) over a wide wavelength range including optical communication bands was achieved without the need for a vacuum chamber.

  16. Spontaneous conversion of first onset atrial fibrillation

    DEFF Research Database (Denmark)

    Lindberg, Søren Østergaard; Hansen, Sidsel; Nielsen, Tonny

    2011-01-01

    Background  We studied all patients admitted to hospital with first onset atrial fibrillation (AF) to determine the probability of spontaneous conversion to sinus rhythm and to identify factors predictive of such a conversion. Methods and Results  We retrospectively reviewed charts of 438...

  17. Towards short wavelengths FELs workshop

    International Nuclear Information System (INIS)

    Ben-Zvi, I.; Winick, H.

    1993-01-01

    This workshop was caged because of the growing perception in the FEL source community that recent advances have made it possible to extend FEL operation to wavelengths about two orders of magnitude shorter than the 240 nm that has been achieved to date. In addition short wavelength FELs offer the possibilities of extremely high peak power (several gigawatts) and very short pulses (of the order of 100 fs). Several groups in the USA are developing plans for such short wavelength FEL facilities. However, reviewers of these plans have pointed out that it would be highly desirable to first carry out proof-of-principle experiments at longer wavelengths to increase confidence that the shorter wavelength devices will indeed perform as calculated. The need for such experiments has now been broadly accepted by the FEL community. Such experiments were the main focus of this workshop as described in the following objectives distributed to attendees: (1) Define measurements needed to gain confidence that short wavelength FELs will perform as calculated. (2) List possible hardware that could be used to carry out these measurements in the near term. (3) Define a prioritized FEL physics experimental program and suggested timetable. (4) Form collaborative teams to carry out this program

  18. Towards short wavelengths FELs workshop

    Science.gov (United States)

    Ben-Zvi, I.; Winick, H.

    1993-11-01

    This workshop was caged because of the growing perception in the FEL source community that recent advances have made it possible to extend FEL operation to wavelengths about two orders of magnitude shorter than the 240 nm that has been achieved to date. In addition short wavelength FEL's offer the possibilities of extremely high peak power (several gigawatts) and very short pulses (of the order of 100 fs). Several groups in the USA are developing plans for such short wavelength FEL facilities. However, reviewers of these plans have pointed out that it would be highly desirable to first carry out proof-of-principle experiments at longer wavelengths to increase confidence that the shorter wavelength devices will indeed perform as calculated. The need for such experiments has now been broadly accepted by the FEL community. Such experiments were the main focus of this workshop as described in the following objectives distributed to attendees: (1) Define measurements needed to gain confidence that short wavelength FEL's will perform as calculated. (2) List possible hardware that could be used to carry out these measurements in the near term. (3) Define a prioritized FEL physics experimental program and suggested timetable. (4) Form collaborative teams to carry out this program.

  19. Dose conversion factors for radiation doses at normal operation discharges. E. Exposure pathways and radioecological data; Dosomraekningsfaktorer foer normaldriftutslaepp. C. Exponeringsvaegar och radioekologiska data

    Energy Technology Data Exchange (ETDEWEB)

    Karlsson, Sara; Aquilonius, Karin

    2001-10-01

    A study has been performed in order to develop and extend existing models for dose estimations at emissions of radioactive substances from nuclear facilities in Sweden. This report presents a review of all exposure pathways in the project, in order to secure that no important contributions have been omitted. The radioecological data that should be used in calculating conversion factors for air and water emissions are also reviewed. Nuclid-specific conversion factors have been calculated for radiation doses from inhalation and intake for children in different age groups.

  20. Calibration-free wavelength-modulation spectroscopy based on a swiftly determined wavelength-modulation frequency response function of a DFB laser.

    Science.gov (United States)

    Zhao, Gang; Tan, Wei; Hou, Jiajia; Qiu, Xiaodong; Ma, Weiguang; Li, Zhixin; Dong, Lei; Zhang, Lei; Yin, Wangbao; Xiao, Liantuan; Axner, Ove; Jia, Suotang

    2016-01-25

    A methodology for calibration-free wavelength modulation spectroscopy (CF-WMS) that is based upon an extensive empirical description of the wavelength-modulation frequency response (WMFR) of DFB laser is presented. An assessment of the WMFR of a DFB laser by the use of an etalon confirms that it consists of two parts: a 1st harmonic component with an amplitude that is linear with the sweep and a nonlinear 2nd harmonic component with a constant amplitude. Simulations show that, among the various factors that affect the line shape of a background-subtracted peak-normalized 2f signal, such as concentration, phase shifts between intensity modulation and frequency modulation, and WMFR, only the last factor has a decisive impact. Based on this and to avoid the impractical use of an etalon, a novel method to pre-determine the parameters of the WMFR by fitting to a background-subtracted peak-normalized 2f signal has been developed. The accuracy of the new scheme to determine the WMFR is demonstrated and compared with that of conventional methods in CF-WMS by detection of trace acetylene. The results show that the new method provides a four times smaller fitting error than the conventional methods and retrieves concentration more accurately.

  1. Making Displaced Holograms At Two Wavelengths

    Science.gov (United States)

    Witherow, William K.; Ecker, Andreas

    1989-01-01

    Two-wavelength holographic system augmented with pair of prisms to introduce small separation between holograms formed simultaneously at two wavelengths on holographic plate. Principal use in study of flows. Gradients in index of refraction of fluid caused by variations in temperature, concentration, or both. Holography at one wavelength cannot be used to distinguish between two types of variations. Difference between spacings of fringes in photographs reconstructed from holograms taken simultaneously at two different wavelengths manipulated mathematically to determine type of variation.

  2. Renewal and maintenance of a nuclear structure data file used for the calculations of dose conversion factors

    International Nuclear Information System (INIS)

    Togawa, Orihiko; Yamaguchi, Yukichi

    1996-02-01

    The ENSDF decay data are used as fundamental data to compute radiation data in the DOSDAC code system, which was developed at JAERI, for the calculation of dose conversion factors. The ENSDF decay data have been periodically revised by reviewing new experimental data in the literature under an international network. The use of this data file enables us to calculate radiation data from information which is the newest and internationally recognized. In spite of this advantage, the decay data file is seldom used in applied fields. This is due to some problems to be solved from a viewpoint of the calculation of radiation data, as well as its complicated structure. This report describes methods for renewal and maintenance of the ENSDF decay data used for the calculation of dose conversion factors. In case that the decay data are used directly, attention should be sometimes paid to some problems, for example defects in data. In renewing and using the ENSDF decay data, the DOSDAC code system tries to avoid wrong calculations of radiation data by check and modification of defects in data through four supporting computer codes. (author)

  3. Biosphere analysis - a complementary assessment of dose conversion factors for the Olkiluoto site

    International Nuclear Information System (INIS)

    Kylloenen, J.; Keto, V.

    2010-04-01

    The Olkiluoto site is currently the primary candidate for the final disposal site for spent nuclear fuel from the Olkiluoto and Loviisa NPPs. Safety analysis calculations must be performed to verify the compliance with the long-term safety requirements. The behaviour and distribution of radionuclides in the biosphere is of high importance in these calculations. The aim of this study was to perform a complementary assessment of dose conversion factors for the Olkiluoto site. Posiva has performed extensive analysis on the different ecosystems. In this work the biosphere analysis model of Fortum Nuclear Services (FNS) is used to give an independent estimate of biosphere dose conversion factors for the Olkiluoto site. The following nuclides are analysed: Cl-36, Ni-59, Se-79, Mo-93, Nb-94, Sn-126, I-129 and Cs-135. The FNS model is an equilibrium compartment model in which a steady annual release of 1 Bq of each radionuclide is distributed in different scenarios. The scenarios are the well scenario, which models a small agricultural ecosystem, the lake scenario which models a larger ecosystem with both agriculture and lake use, and sea and transition scenario, which models the behaviour of the radionuclides in marine environments. The scenarios are described and the transfer equations written for the lake scenario. The parameter values are taken from the FNS biosphere database, which has been used in the Finnish L/ILW waste repository safety analyses since mid 1990's. The results of the FNS analysis are compared to those presented in Posiva working report 2000-20 (POSIVA-WR-00-20). The results are of the same order of magnitude for all nuclides except I-129. Since the Posiva and FNS models were independently constructed, the results can be considered as convincing, and the compliance of the results give confidence to the modelling results. (orig.)

  4. Heralded wave packet manipulation and storage of a frequency-converted pair photon at telecom wavelength

    Science.gov (United States)

    Kroh, Tim; Ahlrichs, Andreas; Sprenger, Benjamin; Benson, Oliver

    2017-09-01

    Future quantum networks require a hybrid platform of dissimilar quantum systems. Within the platform, joint quantum states have to be mediated either by single photons, photon pairs or entangled photon pairs. The photon wavelength has to lie within the telecommunication band to enable long-distance fibre transmission. In addition, the temporal shape of the photons needs to be tailored to efficiently match the involved quantum systems. Altogether, this requires the efficient coherent wavelength-conversion of arbitrarily shaped single-photon wave packets. Here, we demonstrate the heralded temporal filtering of single photons as well as the synchronisation of state manipulation and detection as key elements in a typical experiment, besides of delaying a photon in a long fibre. All three are realised by utilising commercial telecommunication fibre-optical components which will permit the transition of quantum networks from the lab to real-world applications. The combination of these renders a temporally filtering single-photon storage in a fast switchable fibre loop possible.

  5. Optimizing image-based patterned defect inspection through FDTD simulations at multiple ultraviolet wavelengths

    Science.gov (United States)

    Barnes, Bryan M.; Zhou, Hui; Henn, Mark-Alexander; Sohn, Martin Y.; Silver, Richard M.

    2017-06-01

    The sizes of non-negligible defects in the patterning of a semiconductor device continue to decrease as the dimensions for these devices are reduced. These "killer defects" disrupt the performance of the device and must be adequately controlled during manufacturing, and new solutions are required to improve optics-based defect inspection. To this end, our group has reported [Barnes et al., Proc. SPIE 1014516 (2017)] our initial five-wavelength simulation study, evaluating the extensibility of defect inspection by reducing the inspection wavelength from a deep-ultraviolet wavelength to wavelengths in the vacuum ultraviolet and the extreme ultraviolet. In that study, a 47 nm wavelength yielded enhancements in the signal to noise (SNR) by a factor of five compared to longer wavelengths and in the differential intensities by as much as three orders-of-magnitude compared to 13 nm. This paper briefly reviews these recent findings and investigates the possible sources for these disparities between results at 13 nm and 47 nm wavelengths. Our in-house finite-difference time-domain code (FDTD) is tested in both two and three dimensions to determine how computational conditions contributed to the results. A modified geometry and materials stack is presented that offers a second viewpoint of defect detectability as functions of wavelength, polarization, and defect type. Reapplication of the initial SNR-based defect metric again yields no detection of a defect at λ = 13 nm, but additional image preprocessing now enables the computation of the SNR for λ = 13 nm simulated images and has led to a revised defect metric that allows comparisons at all five wavelengths.

  6. Wavelength dependence of interstellar polarization

    International Nuclear Information System (INIS)

    Mavko, G.E.

    1974-01-01

    The wavelength dependence of interstellar polarization was measured for twelve stars in three regions of the Milky Way. A 120A bandpass was used to measure the polarization at a maximum of sixteen wavelengths evenly spaced between 2.78μ -1 (3600A) and 1.28μ -1 (7800A). For such a wide wavelength range, the wavelength resolution is superior to that of any previously reported polarization measurements. The new scanning polarimeter built by W. A. Hiltner of the University of Michigan was used for the observations. Very broad structure was found in the wavelength dependence of the polarization. Extensive investigations were carried out to show that the structure was not caused by instrumental effects. The broad structure observed is shown to be in agreement with concurrent extinction measurements for the same stars. Also, the observed structure is of the type predicted when a homogeneous silicate grain model is fitted to the observed extinction. The results are in agreement with the hypothesis that the very broad band structure seen in the extinction is produced by the grains. (Diss. Abstr. Int., B)

  7. Nitrogen-to-Protein Conversion Factors for Three Edible Insects: Tenebrio molitor, Alphitobius diaperinus, and Hermetia illucens.

    Science.gov (United States)

    Janssen, Renske H; Vincken, Jean-Paul; van den Broek, Lambertus A M; Fogliano, Vincenzo; Lakemond, Catriona M M

    2017-03-22

    Insects are considered a nutritionally valuable source of alternative proteins, and their efficient protein extraction is a prerequisite for large-scale use. The protein content is usually calculated from total nitrogen using the nitrogen-to-protein conversion factor (Kp) of 6.25. This factor overestimates the protein content, due to the presence of nonprotein nitrogen in insects. In this paper, a specific Kp of 4.76 ± 0.09 was calculated for larvae from Tenebrio molitor, Alphitobius diaperinus, and Hermetia illucens, using amino acid analysis. After protein extraction and purification, a Kp factor of 5.60 ± 0.39 was found for the larvae of three insect species studied. We propose to adopt these Kp values for determining protein content of insects to avoid overestimation of the protein content.

  8. Epitaxially-grown Gallium Nitride on Gallium Oxide substrate for photon pair generation in visible and telecomm wavelengths

    KAUST Repository

    Awan, Kashif M.

    2016-08-11

    Gallium Nitride (GaN), along with other III-Nitrides, is attractive for optoelectronic and electronic applications due to its wide direct energy bandgap, as well as high thermal stability. GaN is transparent over a wide wavelength range from infra-red to the visible band, which makes it suitable for lasers and LEDs. It is also expected to be a suitable candidate for integrated nonlinear photonic circuits for a wide range of applications from all-optical signal processing to quantum computing and on-chip wavelength conversion. Despite its abundant use in commercial devices, there is still need for suitable substrate materials to reduce high densities of threading dislocations (TDs) and other structural defects like stacking faults, and grain boundaries. All these defects degrade the optical quality of the epi-grown GaN layer as they act as non-radiative recombination centers.

  9. Epitaxially-grown Gallium Nitride on Gallium Oxide substrate for photon pair generation in visible and telecomm wavelengths

    KAUST Repository

    Awan, Kashif M.; Dolgaleva, Ksenia; Mumthaz Muhammed, Mufasila; Roqan, Iman S.

    2016-01-01

    Gallium Nitride (GaN), along with other III-Nitrides, is attractive for optoelectronic and electronic applications due to its wide direct energy bandgap, as well as high thermal stability. GaN is transparent over a wide wavelength range from infra-red to the visible band, which makes it suitable for lasers and LEDs. It is also expected to be a suitable candidate for integrated nonlinear photonic circuits for a wide range of applications from all-optical signal processing to quantum computing and on-chip wavelength conversion. Despite its abundant use in commercial devices, there is still need for suitable substrate materials to reduce high densities of threading dislocations (TDs) and other structural defects like stacking faults, and grain boundaries. All these defects degrade the optical quality of the epi-grown GaN layer as they act as non-radiative recombination centers.

  10. Polarization-sensitive color in butterfly scales: polarization conversion from ridges with reflecting elements.

    Science.gov (United States)

    Zhang, Ke; Tang, Yiwen; Meng, Jinsong; Wang, Ge; Zhou, Han; Fan, Tongxiang; Zhang, Di

    2014-11-03

    Polarization-sensitive color originates from polarization-dependent reflection or transmission, exhibiting abundant light information, including intensity, spectral distribution, and polarization. A wide range of butterflies are physiologically sensitive to polarized light, but the origins of polarized signal have not been fully understood. Here we systematically investigate the colorful scales of six species of butterfly to reveal the physical origins of polarization-sensitive color. Microscopic optical images under crossed polarizers exhibit their polarization-sensitive characteristic, and micro-structural characterizations clarify their structural commonality. In the case of the structural scales that have deep ridges, the polarization-sensitive color related with scale azimuth is remarkable. Periodic ridges lead to the anisotropic effective refractive indices in the parallel and perpendicular grating orientations, which achieves form-birefringence, resulting in the phase difference of two different component polarized lights. Simulated results show that ridge structures with reflecting elements reflect and rotate the incident p-polarized light into s-polarized light. The dimensional parameters and shapes of grating greatly affect the polarization conversion process, and the triangular deep grating extends the outstanding polarization conversion effect from the sub-wavelength period to the period comparable to visible light wavelength. The parameters of ridge structures in butterfly scales have been optimized to fulfill the polarization-dependent reflection for secret communication. The structural and physical origin of polarization conversion provides a more comprehensive perspective on the creation of polarization-sensitive color in butterfly wing scales. These findings show great potential in anti-counterfeiting technology and advanced optical material design.

  11. A small-form-factor piezoelectric vibration energy harvester using a resonant frequency-down conversion

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Kyung Ho; Kim, Young-Cheol [Department of System Dynamics, Korea Institute of Machinery and Materials, 156 Gajeongbuk-Ro, Yuseong-Gu, Daejeon 305-343 (Korea, Republic of); Kim, Jae Eun, E-mail: jekim@cu.ac.kr [School of Mechanical and Automotive Engineering, Catholic University of Daegu, 13-13 Hayang-Ro, Hayang-Eup, Gyeongsan-Si, Gyeongsangbuk-Do 712-702 (Korea, Republic of)

    2014-10-15

    While environmental vibrations are usually in the range of a few hundred Hertz, small-form-factor piezoelectric vibration energy harvesters will have higher resonant frequencies due to the structural size effect. To address this issue, we propose a resonant frequency-down conversion based on the theory of dynamic vibration absorber for the design of a small-form-factor piezoelectric vibration energy harvester. The proposed energy harvester consists of two frequency-tuned elastic components for lowering the first resonant frequency of an integrated system but is so configured that an energy harvesting beam component is inverted with respect to the other supporting beam component for a small form factor. Furthermore, in order to change the unwanted modal characteristic of small separation of resonant frequencies, as is the case with an inverted configuration, a proof mass on the supporting beam component is slightly shifted toward a second proof mass on the tip of the energy harvesting beam component. The proposed small-form-factor design capability was experimentally verified using a fabricated prototype with an occupation volume of 20 × 39 × 6.9 mm{sup 3}, which was designed for a target frequency of as low as 100 Hz.

  12. A small-form-factor piezoelectric vibration energy harvester using a resonant frequency-down conversion

    Directory of Open Access Journals (Sweden)

    Kyung Ho Sun

    2014-10-01

    Full Text Available While environmental vibrations are usually in the range of a few hundred Hertz, small-form-factor piezoelectric vibration energy harvesters will have higher resonant frequencies due to the structural size effect. To address this issue, we propose a resonant frequency-down conversion based on the theory of dynamic vibration absorber for the design of a small-form-factor piezoelectric vibration energy harvester. The proposed energy harvester consists of two frequency-tuned elastic components for lowering the first resonant frequency of an integrated system but is so configured that an energy harvesting beam component is inverted with respect to the other supporting beam component for a small form factor. Furthermore, in order to change the unwanted modal characteristic of small separation of resonant frequencies, as is the case with an inverted configuration, a proof mass on the supporting beam component is slightly shifted toward a second proof mass on the tip of the energy harvesting beam component. The proposed small-form-factor design capability was experimentally verified using a fabricated prototype with an occupation volume of 20 × 39 × 6.9 mm3, which was designed for a target frequency of as low as 100 Hz.

  13. Culture and conversion disorder: implications for DSM-5.

    Science.gov (United States)

    Brown, Richard J; Lewis-Fernández, Roberto

    2011-01-01

    The diagnostic criteria and related features of conversion disorder are under revision for DSM-5, including the requirement that psychological factors accompany the symptoms or deficits in question (Criterion B) and whether conversion disorder should be re-labeled as a dissociative, rather than a somatoform, condition. We examined the cross-cultural evidence on the prevalence, characteristics, and associated features of pseudoneurological symptoms more generally, and conversion disorder in particular, in order to inform the ongoing re-evaluation of the conversion disorder category. We also examined the relationship between these constructs and dissociative symptoms and disorders across cultural groups. Searches were conducted of the mental health literature, particularly since 1994, regarding culture, race, or ethnicity factors related to conversion disorder. Many proposed DSM-5 revisions were supported, such as the elimination of Criterion B. We also found cross-cultural variability in predominant symptoms, disorder prevalence, and relationship with cultural syndromes. Additional information that may contribute to DSM-5 includes the elevated rates across cultures of traumatic exposure and psychiatric comorbidity in conversion disorder. Cross-culturally, conversion disorder is associated strongly with both dissociative and somatoform presentations, revealing no clear basis on which to locate the disorder in DSM-5. Careful consideration should be given to the possible alternatives.

  14. Psychometric properties of Conversion Disorder Scale- Revised (CDS) for children.

    Science.gov (United States)

    Ijaz, Tazvin; Nasir, Attikah; Sarfraz, Naema; Ijaz, Shirmeen

    2017-05-01

    To revise conversion disorder scale and to establish the psychometric properties of the revised scale. This case-control study was conducted from February to June, 2014, at the Government College University, Lahore, Pakistan, and comprised schoolchildren and children with conversion disorder. In order to generate items for revised version of conversion disorder scale, seven practising mental health professionals were consulted. A list of 42 items was finalised for expert ratings. After empirical validation, a scale of 40 items was administered on the participants and factor analysis was conducted. Of the240 participants, 120(50%) were schoolchildren (controls group) and 120(50%)were children with conversion disorder (clinical group).The results of factor analysis revealed five factors (swallowing and speech symptoms, motor symptoms, sensory symptoms, weakness and fatigue, and mixed symptoms) and retention of all 40 items of revised version of conversion disorder scale. Concurrent validity of the revised scale was found to be 0.81 which was significantly high. Similarly, discriminant validity of the scale was also high as both clinical and control groups had significant difference (pconversion disorder scale was 76% sensitive to predicting conversion disorder while specificity showed that the scale was 73% accurate in specifying participants of the control group. The revised version of conversion disorder scale was a reliable and valid tool to be used for screening of children with conversion disorder.

  15. Conversational Styles and Misunderstanding in Cross-Sex Conversations in He’s Just Not That into You Movie

    Directory of Open Access Journals (Sweden)

    Ayu Nyoman Aryani

    2017-01-01

    Full Text Available Conversation is a social interaction among societies. In this case, gender differences in daily communication lead to men’s and women’s different point of views in performing styles of the conversations. Misunderstanding is likely to occur in crosssex conversations when the idea or thought are understood differently by men and women. This study was intended to analyze the use of conversational styles by men and women and also investigate the misunderstanding phenomena that happened in cross-sex conversations. The researcher identified that the conversational styles used by Alex as a male character in the cross-sex conversations were qualifiers, controlling the topics, verbal fillers, intensifiers, swear words, compound requests, tag questions, questions, interruptions, overlapping, and talk domination. Meanwhile, Gigi, as a female character used qualifiers, controlling the topics, verbal fillers, intensifiers, swear words, tag questions, questions, interruptions, overlapping, talk domination, and silence. In answering the second question, the researcher discovered factors that affected the misunderstanding in the cross-sex conversations between Alex and Gigi were involvement versus independence and message versus metamessage.   DOI: https://doi.org/10.24071/llt.2016.190101

  16. Conversion Intentions of Interns: What Are the Motivating Factors?

    Science.gov (United States)

    Hurst, Jessica L.; Good, Linda K.; Gardner, Phil

    2012-01-01

    Purpose: The purpose of this study is to investigate interns' supervisory support expectations, psychological contract obligations, job satisfaction, perception of advancement opportunities and affective organisational commitment in an attempt to gain a better understanding of how these variables influence interns' conversion intentions.…

  17. Topology optimised wavelength dependent splitters

    DEFF Research Database (Denmark)

    Hede, K. K.; Burgos Leon, J.; Frandsen, Lars Hagedorn

    A photonic crystal wavelength dependent splitter has been constructed by utilising topology optimisation1. The splitter has been fabricated in a silicon-on-insulator material (Fig. 1). The topology optimised wavelength dependent splitter demonstrates promising 3D FDTD simulation results....... This complex photonic crystal structure is very sensitive against small fabrication variations from the expected topology optimised design. A wavelength dependent splitter is an important basic building block for high-performance nanophotonic circuits. 1J. S. Jensen and O. Sigmund, App. Phys. Lett. 84, 2022...

  18. Electron dose-rate conversion factors for external exposure of the skin from uniformly deposited activity on the body surface

    International Nuclear Information System (INIS)

    Kocher, D.C.; Eckerman, K.F.

    1987-01-01

    Dose-rate conversion factors have been calculated for external exposure of the skin from electrons emitted by sources that are deposited uniformly on the body surface. The dose-rate factors are obtained from electron scaled point kernels developed by Berger. The dose-rate factors are calculated at depths of 4, 8, and 40 mg cm-2 below the body surface as recommended by Whitton, and at a depth of 7 mg cm-2 as recommended in ICRP Publication 26 (ICRP77). The dependence of the dose-rate factors at selected depths on the energy of the emitted electrons is displayed. The dose-rate factors for selected radionuclides of potential importance in radiological assessments are tabulated

  19. High-accuracy measurements of snow Bidirectional Reflectance Distribution Function at visible and NIR wavelengths – comparison with modelling results

    Directory of Open Access Journals (Sweden)

    M. Dumont

    2010-03-01

    Full Text Available High-accuracy measurements of snow Bidirectional Reflectance Distribution Function (BRDF were performed for four natural snow samples with a spectrogonio-radiometer in the 500–2600 nm wavelength range. These measurements are one of the first sets of direct snow BRDF values over a wide range of lighting and viewing geometry. They were compared to BRDF calculated with two optical models. Variations of the snow anisotropy factor with lighting geometry, wavelength and snow physical properties were investigated. Results show that at wavelengths with small penetration depth, scattering mainly occurs in the very top layers and the anisotropy factor is controlled by the phase function. In this condition, forward scattering peak or double scattering peak is observed. In contrast at shorter wavelengths, the penetration of the radiation is much deeper and the number of scattering events increases. The anisotropy factor is thus nearly constant and decreases at grazing observation angles. The whole dataset is available on demand from the corresponding author.

  20. Effective wavelength calibration for moire fringe projection

    International Nuclear Information System (INIS)

    Purcell, Daryl; Davies, Angela; Farahi, Faramarz

    2006-01-01

    The fringe patterns seen when using moire instruments are similar to the patterns seen in traditional interferometry but differ in the spacing between consecutive fringes. In traditional interferometry, the spacing is constant and related to the wavelength of the source. In moire fringe projection, the spacing (the effective wavelength) may not be constant over the field of view and the spacing depends on the system geometry. In these cases, using a constant effective wavelength over the field of view causes inaccurate surface height measurements. We examine the calibration process of the moirefringe projection measurement, which takes this varying wavelength into account to produce a pixel-by-pixel wavelength map. The wavelength calibration procedure is to move the object in the out-of-plane direction a known distance until every pixel intensity value goes through at least one cycle. A sinusoidal function is then fit to the data to extract the effective wavelength pixel by pixel, yielding an effective wavelength map. A calibrated step height was used to validate the effective wavelength map with results within 1% of the nominal value of the step height. The error sources that contributed to the uncertainty in determining the height of the artifact are also investigated

  1. All-Optical Ultra-High-Speed OFDM to Nyquist-WDM Conversion Based on Complete Optical Fourier Transformation

    DEFF Research Database (Denmark)

    Guan, Pengyu; Røge, Kasper Meldgaard; Mulvad, Hans Christian Hansen

    2016-01-01

    We propose a novel all-optical ultra-high-speed orthogonal frequency-division multiplexing (OFDM) to Nyquist wavelength-division multiplexing (Nyquist-WDM) conversion scheme, achieved by exchanging the temporal and spectral profiles using a complete optical Fourier transformation (OFT). This scheme...... enables high-speed OFDM to Nyquist-WDM conversion without complex optical/electrical/optical conversion. The all-optical OFDM transmitter is based on the generation of OFDM symbols with a low duty cycle by rectangular temporal gating, which in combination with optical time-division multiplexing yields...... a higher symbol-rate OFDM signal. In the receiver, the converted Nyquist-WDM super-channel is WDM demultiplexed into individual Nyquist-WDM channels using a rectangular optical bandpass filter, followed by optical sampling at the intersymbol-interference free point. In the experimental demonstration...

  2. Proinflammatory cytokine levels in patients with conversion disorder.

    Science.gov (United States)

    Tiyekli, Utkan; Calıyurt, Okan; Tiyekli, Nimet Dilek

    2013-06-01

    It was aimed to evaluate the relationship between proinflammatory cytokine levels and conversion disorder both commonly known as stress regulated. Baseline proinflammatory cytokine levels-[Tumour necrosis factor alpha (TNF-α), Interleukin-1 beta (IL-1β), Interleukin-6 (IL-6)]-were evaluated with enzyme-linked immunosorbent assay in 35 conversion disorder patients and 30 healthy controls. Possible changes in proinflammatory cytokine levels were evaluated again, after their acute phase in conversion disorder patients. Statistically significant decreased serum TNF-α levels were obtained in acute phase of conversion disorder. Those levels increased after acute conversion phase. There were no statistically significant difference observed between groups in serum IL-1β and (IL-6) levels. Stress associated with conversion disorder may suppress immune function in acute conversion phase and may have diagnostic and therapeutic value.

  3. Hydrogen photoproduction by photoelectrochemical conversion

    International Nuclear Information System (INIS)

    Anon.

    1989-01-01

    The water-splitting reaction by photoelectrochemical processes has gained much more attention than any of many reactions proposed for solar generation of energy-rich molecules (fuels). The conversion efficiency of the photosystem is the key factor. The higher the efficiency, the more economically feasible will be the conversion scheme. The conversion efficiency is a function of the semiconductor properties, light intensity, spectral quality, properties of the electrolyte, counterelectrode, cell configuration, etc. The semiconductor parameters include band gap, absorption coefficient and diffusion length. The area and material used for a counterelectrode are important when considering polarization losses in a two-electrode system. Besides, the stability problem is also a very important one to meet the requirement for practical applications. This paper reviews some important issues on photoelectrochemical generation of hydrogen by water splitting. It includes energy conversion efficiency, market assessment and cost goal, state of the technology, and future directions for research

  4. Large-scale cauliflower-shaped hierarchical copper nanostructures for efficient photothermal conversion

    Science.gov (United States)

    Fan, Peixun; Wu, Hui; Zhong, Minlin; Zhang, Hongjun; Bai, Benfeng; Jin, Guofan

    2016-07-01

    Efficient solar energy harvesting and photothermal conversion have essential importance for many practical applications. Here, we present a laser-induced cauliflower-shaped hierarchical surface nanostructure on a copper surface, which exhibits extremely high omnidirectional absorption efficiency over a broad electromagnetic spectral range from the UV to the near-infrared region. The measured average hemispherical absorptance is as high as 98% within the wavelength range of 200-800 nm, and the angle dependent specular reflectance stays below 0.1% within the 0-60° incident angle. Such a structured copper surface can exhibit an apparent heating up effect under the sunlight illumination. In the experiment of evaporating water, the structured surface yields an overall photothermal conversion efficiency over 60% under an illuminating solar power density of ~1 kW m-2. The presented technology provides a cost-effective, reliable, and simple way for realizing broadband omnidirectional light absorptive metal surfaces for efficient solar energy harvesting and utilization, which is highly demanded in various light harvesting, anti-reflection, and photothermal conversion applications. Since the structure is directly formed by femtosecond laser writing, it is quite suitable for mass production and can be easily extended to a large surface area.Efficient solar energy harvesting and photothermal conversion have essential importance for many practical applications. Here, we present a laser-induced cauliflower-shaped hierarchical surface nanostructure on a copper surface, which exhibits extremely high omnidirectional absorption efficiency over a broad electromagnetic spectral range from the UV to the near-infrared region. The measured average hemispherical absorptance is as high as 98% within the wavelength range of 200-800 nm, and the angle dependent specular reflectance stays below 0.1% within the 0-60° incident angle. Such a structured copper surface can exhibit an apparent

  5. Switching speeds in NCAP displays: dependence on collection angle and wavelength

    Science.gov (United States)

    Reamey, Robert H.; Montoya, Wayne; Wartenberg, Mark

    1991-06-01

    The on and off switching speeds of nematic droplet-polymer films (NCAP) are shown to depend on the collection angle (f/#) and the wavelength of the light used in the measurement. Conventional twisted nematic liquid crystal displays have switching speeds which depend little on these factors. The switching speed dependence on collection angle (f/#) and wavelength for nematic droplet-polymer films is inherent to the mechanism by which light is modulated in these films. This mechanism is the scattering of light by the nematic droplets. The on times become faster and the off times become slower as the collection angle of detection is increased. The overall change in switching speed can be large. Greater than 100X changes in off time have been observed. As the wavelength of the light used to interrogate the sample is increased (blue yields green yields red) the on times become faster and the off times become slower. This dependence of switching speed on wavelength is apparent at all collection angles. An awareness of these effects is necessary when developing nematic droplet-polymer films for display applications and when comparing switching speed data from different sources.

  6. The Story of Serum Prothrombin Conversion Accelerator, Proconvertin, Stable Factor, Cothromboplastin, Prothrombin Accelerator or Autoprothrombin I, and Their Subsequent Merging into Factor VII.

    Science.gov (United States)

    Girolami, Antonio; Cosi, Elisabetta; Santarossa, Claudia; Ferrari, Silvia; Luigia Randi, Maria

    2015-06-01

    Factor VII (FVII) deficiency is one of the two congenital coagulation disorders that was not discovered by the description of a new bleeding patient whose clotting pattern did not fit the blood coagulation knowledge of the time (the other is factor XIII deficiency). The existence of an additional factor capable of accelerating the conversion of prothrombin into thrombin was suspected before 1951, the year in which the first family with FVII deficiency was discovered. As several investigators were involved in the discovery of FVII deficiency from both sides of the Atlantic, several different names were tentatively suggested to define this entity, namely stable factor (in contrast with labile factor or FV), cothromboplastin, proconvertin, serum prothrombin conversion accelerator, prothrombin acceleration, and autoprothrombin I. The last term was proposed by those who denied the existence of this new entity, which was instead considered to be a derivate of prothrombin activation, namely autoprothrombin. The description of several families, from all over the world, of the same defect, however clearly demonstrated the singularity of the condition. Factor VII was then proposed to define this protein. In subsequent years, several variants were described with peculiar reactivity toward tissue thromboplastins of different origin. Molecular biology techniques demonstrated several gene mutations, usually missense mutations, often involving exon 8 of the FVII gene. Later studies dealt with the relation of FVII with tissue factor and activated FVII (FVIIa). The evaluation of circulating FVIIa was made possible by the use of a truncated form of tissue factor, which is only sensitive to FVIIa present in the circulation. The development of FVII concentrates, both plasma derived and recombinant, has facilitated therapeutic management of FVII-deficient patients. The use of FVIIa concentrates was noted to be associated with the occasional occurrence of thrombotic events, mainly

  7. Long-wavelength limit of the static structure factors for mixtures of two simple molten salts with a common ion and generalized Bhatia-Thornton formalism: Molecular dynamics study of molten mixture Ag(Br0.7I0.3)

    International Nuclear Information System (INIS)

    Bitrian, Vicente; Trullas, Joaquim; Silbert, Moises

    2008-01-01

    The relation between thermodynamic properties and the long-wavelength limit of the structure factors for mixtures of two simple molten salts with a common ion is derived. While the long-wavelength limit of the partial structure factors for binary ionic systems is directly related to the isothermal compressibility, for ternary ionic systems it is shown that it is also related to the mean square thermal fluctuation in the relative concentration of the non-common ions. This result leads to a generalization of the Bhatia-Thornton formalism. From the local fluctuations in the total number-density, charge-density, and relative concentration, six static structure factors, and the corresponding spatial correlation functions, are defined. By introducing three complementary structure factors, it is possible to describe either these mixtures as a system of cations and anions irrespective of the species of the non-common ions, or solely the binary subsystem of the non-common ions. The generalized structure factors and their long-wavelength limits are illustrated by molecular dynamics simulation results of the molten mixture Ag(Br 0.7 I 0.3 ). The mixture retains the charge order characteristic of pure molten monovalent salts and the topological order observed in monovalent ionic melts in which the cations are smaller than the anions, while the main trends of the anionic chemical order are those of simple binary alloys. The long-wavelength fluctuations in the local relative concentration are found to be very sensitive to the choice of the short-range interactions between the non-common ions

  8. Compactly packaged monolithic four-wavelength VCSEL array with 100-GHz wavelength spacing for future-proof mobile fronthaul transport.

    Science.gov (United States)

    Lee, Eun-Gu; Mun, Sil-Gu; Lee, Sang Soo; Lee, Jyung Chan; Lee, Jong Hyun

    2015-01-12

    We report a cost-effective transmitter optical sub-assembly using a monolithic four-wavelength vertical-cavity surface-emitting laser (VCSEL) array with 100-GHz wavelength spacing for future-proof mobile fronthaul transport using the data rate of common public radio interface option 6. The wavelength spacing is achieved using selectively etched cavity control layers and fine current adjustment. The differences in operating current and output power for maintaining the wavelength spacing of four VCSELs are fiber without any dispersion-compensation techniques.

  9. Comparison of Radiation Dose Rates with the Flux to Dose Conversion Factors Recommended in ICRP-74 and ICRP-116

    International Nuclear Information System (INIS)

    Jeong, Hae Sun; Kil, A Reum; Lee, Jo Eun; Jeong, Hyo Joon; Kim, Eun Han; Han, Moon Hee; Hwang, Won Tae

    2016-01-01

    The evaluation of radiation shielding has been performed for the design and maintenance of various facilities using radioactive sources such as nuclear fuel, accelerator, and radionuclide. The conversion of flux to dose mainly used in nuclear and radiation fields has been generally made with the dose coefficients presented in ICRP Publication 74 (ICRP- 74), which are produced based on ICRP Publication 60. On the other hand, ICRP Publication 116 (ICRP-116), which adopts the protection system of ICRP Publication 103, has recently been published and provides the dose conversion coefficients calculated with a variety of Monte Carlo codes. The coefficients have more than an update of those in ICRP-74, including new particle types and a greatly expanded energy range. In this study, a shielding evaluation of a specific container for neutron and gamma sources was performed with the MCNP6 code. The dose rates from neutron and gamma-ray sources were calculated using the MCNP6 codes, and these results were based on the flux to dose conversion factors recommended in ICRP-74 and ICRP-116. As a result, the dose rates evaluated with ICRP-74 were generally shown higher than those with ICRP-116. For neutrons, the difference is mainly occurred by the decrease of radiation weighting factors in a part of energy ranges in the ICRP-116 recommendations. For gamma-rays, the ICRP-74 recommendation applied with the kerma approximation leads to overestimated results than the other assessment

  10. AWG Filter for Wavelength Interrogator

    Science.gov (United States)

    Black, Richard J. (Inventor); Costa, Joannes M. (Inventor); Faridian, Fereydoun (Inventor); Moslehi, Behzad (Inventor); Sotoudeh, Vahid (Inventor)

    2015-01-01

    A wavelength interrogator is coupled to a circulator which couples optical energy from a broadband source to an optical fiber having a plurality of sensors, each sensor reflecting optical energy at a unique wavelength and directing the reflected optical energy to an AWG. The AWG has a detector coupled to each output, and the reflected optical energy from each grating is coupled to the skirt edge response of the AWG such that the adjacent channel responses form a complementary pair response. The complementary pair response is used to convert an AWG skirt response to a wavelength.

  11. Effects on microstrain and conversion of flowable resin composite using different curing modes and units.

    Science.gov (United States)

    Tseng, Wan-Yu; Chen, Ruey-Song; Wang, Jaw-Lin; Lee, Ming-Shu; Rueggeberg, Frederick A; Chen, Min-Huey

    2007-05-01

    The flowable resin composite, Tetric Flow, was used to measure microstrain and degree of conversion after hardening with each of three curing machines: XL3000(XL) for 10, 20, 30, and 40 s; Optilux 501 using conventional mode (OC) for 10, 20, 30, and 40 s, as well as Optilux boost (OB, 10 s) and ramp modes (OR, 20 s); and LEDemetron (LEDe) for 10, 20, 30, and 40 s. The emitted power density and spectral distribution of the three light curing units were also measured. The LEDe output energy spectrum was centralized between 425 and 490 nm, which encompasses the excited wavelength of camphorquinone. The microstrain produced by the curing process is as a second-degree polynomial for each light source. The OB microstrain was highest, while the OR microstrain was lower. The ranking in order of degree of monomer conversion was as follows: XL10 conversion cured with OB was significant higher than other curing modes except OC30, OC40, LEDe30, LEDe40, and XL40. The conversion value of XL10 was the lowest. The LEDe produced higher conversion for the same emitted energy compared to the two halogen units.

  12. Towards terahertz detection and calibration through spontaneous parametric down-conversion in the terahertz idler-frequency range generated by a 795 nm diode laser system

    Directory of Open Access Journals (Sweden)

    Vladimir V. Kornienko

    2018-05-01

    Full Text Available We study a calibration scheme for terahertz wave nonlinear-optical detectors based on spontaneous parametric down-conversion. Contrary to the usual low wavelength pump in the green, we report here on the observation of spontaneous parametric down-conversion originating from an in-growth poled lithium niobate crystal pumped with a continuous wave 50 mW, 795 nm diode laser system, phase-matched to a terahertz frequency idler wave. Such a system is more compact and allows for longer poling periods as well as lower losses in the crystal. Filtering the pump radiation by a rubidium-87 vapor cell allowed the frequency-angular spectra to be obtained down to ∼0.5 THz or ∼1 nm shift from the pump radiation line. The presence of an amplified spontaneous emission “pedestal” in the diode laser radiation spectrum significantly hampers the observation of spontaneous parametric down-conversion spectra, in contrast to conventional narrowband gas lasers. Benefits of switching to longer pump wavelengths are pointed out, such as collinear optical-terahertz phase-matching in bulk crystals.

  13. Towards terahertz detection and calibration through spontaneous parametric down-conversion in the terahertz idler-frequency range generated by a 795 nm diode laser system

    Science.gov (United States)

    Kornienko, Vladimir V.; Kitaeva, Galiya Kh.; Sedlmeir, Florian; Leuchs, Gerd; Schwefel, Harald G. L.

    2018-05-01

    We study a calibration scheme for terahertz wave nonlinear-optical detectors based on spontaneous parametric down-conversion. Contrary to the usual low wavelength pump in the green, we report here on the observation of spontaneous parametric down-conversion originating from an in-growth poled lithium niobate crystal pumped with a continuous wave 50 mW, 795 nm diode laser system, phase-matched to a terahertz frequency idler wave. Such a system is more compact and allows for longer poling periods as well as lower losses in the crystal. Filtering the pump radiation by a rubidium-87 vapor cell allowed the frequency-angular spectra to be obtained down to ˜0.5 THz or ˜1 nm shift from the pump radiation line. The presence of an amplified spontaneous emission "pedestal" in the diode laser radiation spectrum significantly hampers the observation of spontaneous parametric down-conversion spectra, in contrast to conventional narrowband gas lasers. Benefits of switching to longer pump wavelengths are pointed out, such as collinear optical-terahertz phase-matching in bulk crystals.

  14. Time-stretch microscopy based on time-wavelength sequence reconstruction from wideband incoherent source

    International Nuclear Information System (INIS)

    Zhang, Chi; Xu, Yiqing; Wei, Xiaoming; Tsia, Kevin K.; Wong, Kenneth K. Y.

    2014-01-01

    Time-stretch microscopy has emerged as an ultrafast optical imaging concept offering the unprecedented combination of the imaging speed and sensitivity. However, dedicated wideband and coherence optical pulse source with high shot-to-shot stability has been mandated for time-wavelength mapping—the enabling process for ultrahigh speed wavelength-encoded image retrieval. From the practical point of view, exploiting methods to relax the stringent requirements (e.g., temporal stability and coherence) for the source of time-stretch microscopy is thus of great value. In this paper, we demonstrated time-stretch microscopy by reconstructing the time-wavelength mapping sequence from a wideband incoherent source. Utilizing the time-lens focusing mechanism mediated by a narrow-band pulse source, this approach allows generation of a wideband incoherent source, with the spectral efficiency enhanced by a factor of 18. As a proof-of-principle demonstration, time-stretch imaging with the scan rate as high as MHz and diffraction-limited resolution is achieved based on the wideband incoherent source. We note that the concept of time-wavelength sequence reconstruction from wideband incoherent source can also be generalized to any high-speed optical real-time measurements, where wavelength is acted as the information carrier

  15. Compact titanium dioxide waveguides with high nonlinearity at telecommunication wavelengths

    DEFF Research Database (Denmark)

    Guan, Xiaowei; Hu, Hao; Oxenløwe, Leif Katsuo

    2018-01-01

    .43 mu m(2)) and a low loss (5.4 +/- 1 dB/cm) at telecommunication wavelengths around 1550 nm have been fabricated and measured. A microring resonator having a 50 mu m radius has been measured to have a loaded quality factor of 53500. Four-wave mixing experiments reveal a nonlinear parameter...

  16. Passively synchronized dual-wavelength Q-switched lasers

    DEFF Research Database (Denmark)

    Janousek, Jiri; Tidemand-Lichtenberg, Peter; Mortensen, Jesper Liltorp

    We present a simple and efficient way of generating synchronized Q-switched pulses at wavelengths hundreds of nanometers apart. This principle can result in new pulsed all-solid-state light sources at new wavelengths based on SFG.......We present a simple and efficient way of generating synchronized Q-switched pulses at wavelengths hundreds of nanometers apart. This principle can result in new pulsed all-solid-state light sources at new wavelengths based on SFG....

  17. Widely tunable broadband deep-ultraviolet to visible wavelength generation by the cross phase modulation in a hollow-core photonic crystal fiber cladding

    International Nuclear Information System (INIS)

    Yuan, J H; Sang, X Z; Wu, Q; Yu, C X; Shen, X W; Wang, K R; Yan, B B; Teng, Y L; Farrell, G; Zhou, G Y; Xia, C M; Han, Y; Li, S G; Hou, L T

    2013-01-01

    The deep-ultraviolet (UV) to visible wavelengths are efficiently generated for the first time by the cross phase modulation (XPM) between the red-shifted solitons and the blue-shifted dispersive waves (DWs) in the fundamental guided mode of the multi-knots of a hollow-core photonic crystal fiber cladding (HC-PCFC). When the femtosecond pulses with a wavelength of 850 nm and average power of 300 mW are coupled into the knots 1–3, the conversion efficiency η uv−v of 11% and bandwidth B uv−v of 100 nm in the deep-UV region are experimentally obtained. The multi-milliwatt ultrashort pulses are tunable over the deep-UV (below 200 nm) to visible spectral region by adjusting the wavelengths of the pump pulses in different knots. It is expected that these widely tunable broadband ultrashort deep-UV–visible pulse sources could have important applications in ultrafast photonics, femtochemisty, photobiology, and UV–visible resonant Raman scattering. (letter)

  18. Experimental generation of discrete ultraviolet wavelength by cascaded intermodal four-wave mixing in a multimode photonic crystal fiber.

    Science.gov (United States)

    Yuan, Jinhui; Kang, Zhe; Li, Feng; Zhang, Xianting; Mei, Chao; Zhou, Guiyao; Sang, Xinzhu; Wu, Qiang; Yan, Binbin; Zhou, Xian; Zhong, Kangping; Wang, Kuiru; Yu, Chongxiu; Farrell, Gerald; Lu, Chao; Tam, Hwa Yaw; Wai, P K A

    2017-09-15

    In this Letter, we demonstrate experimentally for the first time, to the best of our knowledge, discrete ultraviolet (UV) wavelength generation by cascaded intermodal FWM when femtosecond pump pulses at 800 nm are launched into the deeply normal dispersion region of the fundamental guided mode of a multimode photonic crystal fiber (MPCF). For pump pulses at average input powers of P av =450, 550, and 650 mW, the first anti-Stokes waves are generated at the visible wavelength of 538.1 nm through intermodal phase matching between the fundamental and second-order guided mode of the MPCF. The first anti-Stokes waves generated then serve as the secondary pump for the next intermodal FWM process. The second anti-Stokes waves in the form of the third-order guided mode are generated at the UV wavelength of 375.8 nm. The maximum output power is above 10 mW for P av =650  mW. We also confirm that the influences of fiber bending and intermodal walk-offs on the cascaded intermodal FWM-based frequency conversion process are negligible.

  19. Solar Program Assessment: Environmental Factors - Ocean Thermal Energy Conversion.

    Science.gov (United States)

    Energy Research and Development Administration, Washington, DC. Div. of Solar Energy.

    This report presents the environmental problems which may arise with the further development of Ocean Thermal Energy Conversion, one of the eight Federally-funded solar technologies. To provide a background for this environmental analysis, the history and basic concepts of the technology are reviewed, as are its economic and resource requirements.…

  20. Absorbed-dose beam quality conversion factors for cylindrical chambers in high energy photon beams.

    Science.gov (United States)

    Seuntjens, J P; Ross, C K; Shortt, K R; Rogers, D W

    2000-12-01

    Recent working groups of the AAPM [Almond et al., Med. Phys. 26, 1847 (1999)] and the IAEA (Andreo et al., Draft V.7 of "An International Code of Practice for Dosimetry based on Standards of Absorbed Dose to Water," IAEA, 2000) have described guidelines to base reference dosimetry of high energy photon beams on absorbed dose to water standards. In these protocols use is made of the absorbed-dose beam quality conversion factor, kQ which scales an absorbed-dose calibration factor at the reference quality 60Co to a quality Q, and which is calculated based on state-of-the-art ion chamber theory and data. In this paper we present the measurement and analysis of beam quality conversion factors kQ for cylindrical chambers in high-energy photon beams. At least three chambers of six different types were calibrated against the Canadian primary standard for absorbed dose based on a sealed water calorimeter at 60Co [TPR10(20)=0.572, %dd(10)x=58.4], 10 MV [TPR10(20)=0.682, %dd(10)x=69.6), 20 MV (TPR10(20)=0.758, %dd(10)x= 80.5] and 30 MV [TPR10(20) = 0.794, %dd(10)x= 88.4]. The uncertainty on the calorimetric determination of kQ for a single chamber is typically 0.36% and the overall 1sigma uncertainty on a set of chambers of the same type is typically 0.45%. The maximum deviation between a measured kQ and the TG-51 protocol value is 0.8%. The overall rms deviation between measurement and the TG-51 values, based on 20 chambers at the three energies, is 0.41%. When the effect of a 1 mm PMMA waterproofing sleeve is taken into account in the calculations, the maximum deviation is 1.1% and the overall rms deviation between measurement and calculation 0.48%. When the beam is specified using TPR10(20), and measurements are compared with kQ values calculated using the version of TG-21 with corrected formalism and data, differences are up to 1.6% when no sleeve corrections are taken into account. For the NE2571 and the NE2611A chamber types, for which the most literature data are

  1. The Nanticoke conversion study

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-04-01

    A study was conducted to assess the conversion of the Nanticoke coal-fired power plant to cleaner burning natural gas combined-cycle gas turbines. The Nanticoke Generating Station on Lake Erie is responsible for more than 50 per cent of Ontario Power Generation's (OPG) coal-fired electricity production. The OPG is proposing to work towards compliance with the newly signed Ozone Annex to the 1991 Canada-United States Air Quality Agreement which will require fossil-fueled power plants in southern Ontario to reduce their smog-causing nitrogen oxides emissions by about 50 per cent by 2007. This study assessed the emission reduction benefits and financial costs of conversion compared to continuing to operate Nanticoke as a coal-fired plant. The analysis includes a base case set of data on fuel prices, retrofit costs, fuel efficiencies, annual capacity factors and other parameters. It was determined that conversion would cost the average household less than $3 per month on their electricity bill. Conversion would also reduce emissions nitrogen oxide, a major smog pollutant, by 83 per cent and the particulates that form the most health-threatening portion of smog would be reduced by 100 per cent. 15 tabs., 1 fig.

  2. Single-mode fiber laser based on core-cladding mode conversion.

    Science.gov (United States)

    Suzuki, Shigeru; Schülzgen, Axel; Peyghambarian, N

    2008-02-15

    A single-mode fiber laser based on an intracavity core-cladding mode conversion is demonstrated. The fiber laser consists of an Er-doped active fiber and two fiber Bragg gratings. One Bragg grating is a core-cladding mode converter, and the other Bragg grating is a narrowband high reflector that selects the lasing wavelength. Coupling a single core mode and a single cladding mode by the grating mode converter, the laser operates as a hybrid single-mode laser. This approach for designing a laser cavity provides a much larger mode area than conventional large-mode-area step-index fibers.

  3. All passive architecture for high efficiency cascaded Raman conversion

    Science.gov (United States)

    Balaswamy, V.; Arun, S.; Chayran, G.; Supradeepa, V. R.

    2018-02-01

    Cascaded Raman fiber lasers have offered a convenient method to obtain scalable, high-power sources at various wavelength regions inaccessible with rare-earth doped fiber lasers. A limitation previously was the reduced efficiency of these lasers. Recently, new architectures have been proposed to enhance efficiency, but this came at the cost of enhanced complexity, requiring an additional low-power, cascaded Raman laser. In this work, we overcome this with a new, all-passive architecture for high-efficiency cascaded Raman conversion. We demonstrate our architecture with a fifth-order cascaded Raman converter from 1117nm to 1480nm with output power of ~64W and efficiency of 60%.

  4. A silicon superlens with a simple design working at visible wavelengths

    Science.gov (United States)

    Fu, Liwei; Frenner, Karsten; Li, Huiyu; Osten, Wolfgang

    2016-04-01

    Nano-imaging has imposed a fundamental impact on the development of nanoscience and technology. The demands for direct subwavelength imaging in far field have been significantly increased. Such a superlens needs first to be able to collect the near field information, and then transform it into the far field with magnification and low image distortion. In this contribution we demonstrate a superlens with a novel design for far field observation at visible wavelengths. The lens is based on a silicon half cylinder with several micrometers in size. Without any structuring, the silicon semicylinder can already work as a lens with high resolving power due to its high refractive index. A distance of 280 nm between two incoherent dipoles immersed in water can be well resolved at a wavelength of 640 nm. Deep subwavelength imaging with magnification can be achieved when the flat surface of the semi-cylinder is structured with periodic plasmonic grating. When a ridge of the grating is centered at the optical axis of the lens, a local magnification factor of 10 can be obtained and the smallest resolvable distance between two point dipoles in water is around 120 nm at 640 nm wavelength. Moreover, this superlens also works at other visible wavelengths with a similar performance.

  5. Selective labeling of a single organelle by using two-photon conversion of a photoconvertible fluorescent protein

    Science.gov (United States)

    Watanabe, Wataru; Shimada, Tomoko; Matsunaga, Sachihiro; Kurihara, Daisuke; Arimura, Shin-ichi; Tsutsumi, Nobuhiro; Fukui, Kiichi; Itoh, Kazuyoshi

    2008-02-01

    We present space-selective labeling of organelles by using two-photon conversion of a photoconvertible fluorescent protein with near-infrared femtosecond laser pulses. Two-photon excitation of photoconvertible fluorescent-protein, Kaede, enables space-selective labeling of organelles. We alter the fluorescence of target mitochondria in a tobacco BY-2 cell from green to red by focusing femtosecond laser pulses with a wavelength of 750 nm.

  6. Visible light to electrical energy conversion using photoelectrochemical cells

    Science.gov (United States)

    Wrighton, Mark S. (Inventor); Ellis, Arthur B. (Inventor); Kaiser, Steven W. (Inventor)

    1983-01-01

    Sustained conversion of low energy visible or near i.r. light (>1.25 eV) to electrical energy has been obtained using wet photoelectrochemical cells where there are no net chemical changes in the system. Stabilization of n-type semi-conductor anodes of CdS, CdSe, CdTe, GaP, GaAs and InP to photoanodic dissolution is achieved by employing selected alkaline solutions of Na.sub.2 S, Na.sub.2 S/S, Na.sub.2 Se, Na.sub.2 Se/Se, Na.sub.2 Te and Na.sub.2 Te/Te as the electrolyte. The oxidation of (poly) sulfide, (poly)selenide or (poly)telluride species occurs at the irradiated anode, and reduction of polysulfide, polyselenide or polytelluride species occurs at the dark Pt cathode of the photoelectrochemical cell. Optical to electrical energy conversion efficiencies approaching 15% at selected frequencies have been observed in some cells. The wavelength for the onset of photocurrent corresponds to the band gap of the particular anode material used in the cell.

  7. Overall efficiencies for conversion of solar energy to a chemical fuel

    Science.gov (United States)

    Fish, J. D.

    A complete and consistent scheme for determining the overall efficiency of a generalized process for the conversion of solar energy into a chemical fuel (e.g. hydrogen) is developed and applied to seven conversion processes: thermal, thermochemical, photovoltaic, photogalvanic, photoelectrolysis, photosynthesis and photochemical conversion. It is demonstrated that the overall efficiency of each of these processes is determined by ten common factors: maximum theoretical efficiency, inherent absorption losses, inherent internal losses, rate limiting effects, reflection losses, transmission losses, coverage losses, system construction requirements, parasitic losses and harvesting and conversion losses. Both state-of-the-art and optimistic values are assigned to each factor for each of the seven conversion processes. State-of-the-art overall efficiencies ranged from 5% for thermal conversion down to essentially zero for thermochemical. Optimistic values in the range of about 10 to 15% are calculated for several of the processes.

  8. Long-wavelength limit of the static structure factors for mixtures of two simple molten salts with a common ion and generalized Bhatia-Thornton formalism: Molecular dynamics study of molten mixture Ag(Br{sub 0.7}I{sub 0.3})

    Energy Technology Data Exchange (ETDEWEB)

    Bitrian, Vicente [Departament de Fisica i Enginyeria Nuclear, Universitat Politecnica de Catalunya, Campus Nord UPC, Edifici B4-B5, Despatx B4-204, Jordi Girona 1-3, 08034 Barcelona (Spain); Trullas, Joaquim [Departament de Fisica i Enginyeria Nuclear, Universitat Politecnica de Catalunya, Campus Nord UPC, Edifici B4-B5, Despatx B4-204, Jordi Girona 1-3, 08034 Barcelona (Spain)], E-mail: quim.trullas@upc.edu; Silbert, Moises [School of Mathematics, University of East Anglia, Norwich NR4 7QF (United Kingdom)

    2008-12-15

    The relation between thermodynamic properties and the long-wavelength limit of the structure factors for mixtures of two simple molten salts with a common ion is derived. While the long-wavelength limit of the partial structure factors for binary ionic systems is directly related to the isothermal compressibility, for ternary ionic systems it is shown that it is also related to the mean square thermal fluctuation in the relative concentration of the non-common ions. This result leads to a generalization of the Bhatia-Thornton formalism. From the local fluctuations in the total number-density, charge-density, and relative concentration, six static structure factors, and the corresponding spatial correlation functions, are defined. By introducing three complementary structure factors, it is possible to describe either these mixtures as a system of cations and anions irrespective of the species of the non-common ions, or solely the binary subsystem of the non-common ions. The generalized structure factors and their long-wavelength limits are illustrated by molecular dynamics simulation results of the molten mixture Ag(Br{sub 0.7}I{sub 0.3}). The mixture retains the charge order characteristic of pure molten monovalent salts and the topological order observed in monovalent ionic melts in which the cations are smaller than the anions, while the main trends of the anionic chemical order are those of simple binary alloys. The long-wavelength fluctuations in the local relative concentration are found to be very sensitive to the choice of the short-range interactions between the non-common ions.

  9. Photovoltaic conversion efficiency in copper-phthalocyanine/perylenetetracarboxylic acid benzimidazole heterojunction solar cells

    Energy Technology Data Exchange (ETDEWEB)

    Tsutsui, Tetsuo [Dept. of Materials Science and Technology, Graduate School of Engineering Sciences, Kyushu Univ., Fukuoka (Japan); Nakashima, Takuya [Dept. of Materials Science and Technology, Graduate School of Engineering Sciences, Kyushu Univ., Fukuoka (Japan); Fujita, Yoshimasa [Dept. of Materials Science and Technology, Graduate School of Engineering Sciences, Kyushu Univ., Fukuoka (Japan); Saito, Shogo [Dept. of Materials Science and Technology, Graduate School of Engineering Sciences, Kyushu Univ., Fukuoka (Japan)

    1995-04-01

    Energy conversion efficiency of organic heterojuction-type solar cells was analyzed based on a simplified model. Energy conversion efficiency was expressed by four terms, a proton collection factor, a voltage output factor, an average quantum efficiency of photo-carrier generation and a fill factor. Meanings of low values of former two terms were discussed. (orig.)

  10. Uncertainty of the thyroid dose conversion factor for inhalation intakes of 131I and its parametric uncertainty

    International Nuclear Information System (INIS)

    Harvey, R. P.; Hamby, D. M.; Palmer, T. S.

    2006-01-01

    Inhalation exposures of 131 I may occur in the physical form of a gas as well as a particulate. The physical characteristics pertaining to these different types of releases influence the intake and subsequent dose to an exposed individual. The thyroid dose received is influenced by the route through which 131 I enters the body and its subsequent clearance, absorption and movement throughout the body. The radioactive iodine taken up in the gas-exchange tissues is cleared to other tissues or absorbed into the bloodstream of the individual and transferred to other organs. Iodine in the circulatory system is then taken up by the thyroid gland with resulting dose to that tissue. The magnitude of and uncertainty in the thyroid dose is important to the assessment of individuals exposed to airborne releases of radioiodine. Age- and gender-specific modelling parameters have resulted in significant differences between gas uptake, particulate deposition and inhalation dose conversion factors for each age and gender group. Inhalation dose conversion factors and their inherent uncertainty are markedly affected by the type of iodine intake. These differences are expected due to the modelling of particulate deposition versus uptake of gas in the respiratory tract. Inhalation dose estimates via iodine gases are very similar and separate classifications may not be necessarily based on this assessment. (authors)

  11. Short wavelength FELs using the SLAC linac

    International Nuclear Information System (INIS)

    Winick, H.; Bane, K.; Boyce, R.

    1993-08-01

    Recent technological developments have opened the possibility to construct a device which we call a Linac Coherent Light Source (LCLS); a fourth generation light source, with brightness, coherence, and peak power far exceeding other sources. Operating on the principle of the free electron laser (FEL), the LCLS would extend the range of FEL operation to much aborter wavelength than the 240 mn that has so far been reached. We report the results of studies of the use of the SLAC linac to drive an LCLS at wavelengths from about 3-100 nm initially and possibly even shorter wavelengths in the future. Lasing would be achieved in a single pass of a low emittance, high peak current, high energy electron beam through a long undulator. Most present FELs use an optical cavity to build up the intensity of the light to achieve lasing action in a low gain oscillator configuration. By eliminating the optical cavity, which is difficult to make at short wavelengths, laser action can be extended to shorter wavelengths by Self-Amplified-Spontaneous-Emission (SASE), or by harmonic generation from a longer wavelength seed laser. Short wavelength, single pass lasers have been extensively studied at several laboratories and at recent workshops

  12. Sub-wavelength plasmon laser

    Science.gov (United States)

    Bora, Mihail; Bond, Tiziana C.

    2016-04-19

    A plasmonic laser device has resonant nanocavities filled with a gain medium containing an organic dye. The resonant plasmon frequencies of the nanocavities are tuned to align with both the absorption and emission spectra of the dye. Variables in the system include the nature of the dye and the wavelength of its absorption and emission, the wavelength of the pumping radiation, and the resonance frequencies of the nanocavities. In addition the pumping frequency of the dye is selected to be close to the absorption maximum.

  13. Relaxed damage threshold intensity conditions and nonlinear increase in the conversion efficiency of an optical parametric oscillator using a bi-directional pump geometry.

    Science.gov (United States)

    Norris, G; McConnell, G

    2010-03-01

    A novel bi-directional pump geometry that nonlinearly increases the nonlinear optical conversion efficiency of a synchronously pumped optical parametric oscillator (OPO) is reported. This bi-directional pumping method synchronizes the circulating signal pulse with two counter-propagating pump pulses within a linear OPO resonator. Through this pump scheme, an increase in nonlinear optical conversion efficiency of 22% was achieved at the signal wavelength, corresponding to a 95% overall increase in average power. Given an almost unchanged measured pulse duration of 260 fs under optimal performance conditions, this related to a signal wavelength peak power output of 18.8 kW, compared with 10 kW using the traditional single-pass geometry. In this study, a total effective peak intensity pump-field of 7.11 GW/cm(2) (corresponding to 3.55 GW/cm(2) from each pump beam) was applied to a 3 mm long periodically poled lithium niobate crystal, which had a damage threshold intensity of 4 GW/cm(2), without impairing crystal integrity. We therefore prove the application of this novel pump geometry provides opportunities for power-scaling of synchronously pumped OPO systems together with enhanced nonlinear conversion efficiency through relaxed damage threshold intensity conditions.

  14. Analysis of subsystems in wavelength-division-multiplexing networks

    DEFF Research Database (Denmark)

    Liu, Fenghai

    2001-01-01

    Wavelength division multiplexing (WDM) technology together with optical amplification has created a new era for optical communication. Transmission capacity is greatly increased by adding more and more wavelength channels into a single fiber, as well as by increasing the line rate of each channel...... in semiconductor optical amplifiers (SOAs), and dispersion managed fiber sections. New subsystems are also proposed in the thesis: a modular 2×2 multiwavelength cross-connect using wavelength switching blocks, a wavelength converter based on cross phase modulation in a semiconductor modulator, a wavelength...

  15. Embodied Conversational Agents in Clinical Psychology : A Scoping Review

    NARCIS (Netherlands)

    Provoost, Simon; Lau, Ho Ming; Ruwaard, Jeroen; Riper, Heleen

    2017-01-01

    BACKGROUND: Embodied conversational agents (ECAs) are computer-generated characters that simulate key properties of human face-to-face conversation, such as verbal and nonverbal behavior. In Internet-based eHealth interventions, ECAs may be used for the delivery of automated human support factors.

  16. Predicting factors for conversion from fluoroscopy guided Percutaneous transthoracic needle biopsy to cone-beam CT guided Percutaneous transthoracic needle biopsy

    International Nuclear Information System (INIS)

    Lee, Kang Ji; Han, Young Min; Jin, Gong Yong; Song, Ji Soo

    2015-01-01

    To evaluate the predicting factors for conversion from fluoroscopy guided percutaneous transthoracic needle biopsy (PTNB) to cone-beam CT guided PTNB. From January 2011 to December 2012, we retrospectively identified 38 patients who underwent cone-beam CT guided PTNB with solid pulmonary lesions, and 76 patients who underwent fluoroscopy guided PTNB were matched to the patients who underwent cone-beam CT guided PTNB for age, sex, and lesion location. We evaluated predicting factors such as, long-axis diameter, short-axis diameter, anterior-posterior diameter, and CT attenuation value of the solid pulmonary lesion affecting conversion from fluoroscopy guided PTNB to cone-beam CT guided PTNB. Pearson χ 2 test, Fisher exact test, and independent t test were used in statistical analyses; in addition, we also used receiver operating characteristics curve to find the proper cut-off values affecting the conversion to cone-beam CT guided PTNB. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent fluoroscopy guided PTNB were 2.70 ± 1.57 cm, 3.40 ± 1.92 cm, 3.06 ± 1.81 cm, and 35.67 ± 15.70 Hounsfield unit (HU), respectively. Short-axis, long-axis, anterior-posterior diameter and CT attenuation value of the solid pulmonary lesion in patients who underwent cone-beam CT guided PTNB were 1.60 ± 1.30 cm, 2.20 ± 1.45 cm, 1.91 ± 1.99 cm, and 18.32 ± 23.11 HU, respectively. Short-axis, long-axis, anterior-posterior diameter, and CT attenuation value showed a significantly different mean value between the 2 groups (p = 0.001, p < 0.001, p = 0.003, p < 0.001, respectively). Odd ratios of CT attenuation value and short-axis diameter of the solid pulmonary lesion were 0.952 and 0.618, respectively. Proper cut-off values affecting the conversion to cone-beam CT guided PTNB were 1.65 cm (sensitivity 68.4%, specificity 71.1%) in short-axis diameter and 29.50 HU (sensitivity 65.8%, specificity 65.8%) in

  17. Neurologists' understanding and management of conversion disorder.

    Science.gov (United States)

    Kanaan, Richard A; Armstrong, David; Wessely, Simon Charles

    2011-09-01

    Conversion disorder is largely managed by neurologists, for whom it presents great challenges to understanding and management. This study aimed to quantify these challenges, examining how neurologists understand conversion disorder, and what they tell their patients. A postal survey of all consultant neurologists in the UK registered with the Association of British Neurologists. 349 of 591 practising consultant neurologists completed the survey. They saw conversion disorder commonly. While they endorsed psychological models for conversion, they diagnosed it according to features of the clinical presentation, most importantly inconsistency and abnormal illness behaviour. Most of the respondents saw feigning as entangled with conversion disorder, with a minority seeing one as a variant of the other. They were quite willing to discuss psychological factors as long as the patient was receptive but were generally unwilling to discuss feigning even though they saw it as their responsibility. Those who favoured models in terms of feigning were older, while younger, female neurologists preferred psychological models, believed conversion would one day be understood neurologically and found communicating with their conversion patients easier than it had been in the past. Neurologists accept psychological models for conversion disorder but do not employ them in their diagnosis; they do not see conversion as clearly different from feigning. This may be changing as younger, female neurologists endorse psychological views more clearly and find it easier to discuss with their patients.

  18. A tunable dual-wavelength pump source based on simulated polariton scattering for terahertz-wave generation

    International Nuclear Information System (INIS)

    Sun, Bo; Liu, Jinsong; Yao, Jianquan; Li, Enbang

    2013-01-01

    We propose a dual-wavelength pump source by utilizing stimulated polariton scattering in a LiNbO 3 crystal. The residual pump and the generated tunable Stokes waves can be combined to generate THz-wave generation via difference frequency generation (DFG). With a pump energy of 49 mJ, Stokes waves with a tuning range from 1067.8 to 1074 nm have been generated, and an output energy of up to 14.9 mJ at 1070 nm has been achieved with a conversion efficiency of 21.7%. A sum frequency generation experiment was carried out to demonstrate the feasibility of the proposed scheme for THz-wave DFG. (paper)

  19. Wavelength dependent SHG imaging and scattering probes of extracellular matrix (ECM) alterations in ovarian cancer (Conference Presentation)

    Science.gov (United States)

    Campagnola, Paul J.; Tilbury, Karissa B.; Campbell, Kirby R.; Eliceiri, Kevin W.; Patankar, Manish

    2017-02-01

    Ovarian cancer remains the most deadly gynecological cancer with a poor aggregate survival rate. To improve upon this situation, we utilized collagen-specific Second Harmonic Generation (SHG) imaging microscopy and optical scattering measurements to probe structural differences in the extracellular matrix of normal stroma, benign tumors, endometrioid tumors, and low and high-grade serous (LGS and HGS) tumors. The SHG signatures of the emission directionality and conversion efficiency as well as the optical scattering are related to the organization of collagen on the sub-micron size. The wavelength dependence of these readouts adds additional characterization of the size and distribution of collagen fibrils/fibers relative to the interrogating wavelengths. We found strong wavelength dependent dependencies of these metrics that were different between the different tumors that are related to respective structural attributes in the collagen organization. These sub-resolution determinations are consistent with the dualistic classification of type I and II serous tumors. However, type I endometrioid tumors have strongly differing ECM architecture than the serous malignancies. Moreover, our analyses are further consistent with LGS and benign tumors having similar etiology. We identified optimal wavelengths for the SHG metrics as well as optical scattering measurements. The SHG metrics and optical scattering measurements were then used to form a linear discriminant model to classify the tissues, and we obtained high accuracy ( 90%) between the tissue types. This delineation is superior to current clinical performance and has potential applicability in supplementing histological analysis, understanding the etiology, as well as development of an in vivo screening tool.

  20. Forest Conversion, Agricultural Transitions and the Influence of Multi-scale Market Factors in Southwest Cameroon

    Science.gov (United States)

    Ordway, E.; Lambin, E.; Asner, G. P.

    2015-12-01

    The changing structure of demand for commodities associated with food security and energy has had a startling impact on land use change in tropical forests in recent decades. Yet, the composition of conversion in the Congo basin remains a major uncertainty, particularly with regards to the scale of drivers of change. Owing to rapid expansion of production globally and longstanding historical production locally in the Congo basin, oil palm offers a lens through which to evaluate local land use decisions across a spectrum of small- to large-scales of production as well as interactions with regional and global supply chains. We examined the effect of global commodity crop expansion on land use change in Southwest Cameroon using a mixed-methods approach to integrate remote sensing, field surveys and socioeconomic data. Southwest Cameroon (2.5 Mha) has a long history of large- and small-scale agriculture, ranging from mixed crop subsistence agriculture to large monocrop plantations of oil palm, cocoa, and rubber. Trends and spatial patterns of forest conversion and agricultural transitions were analyzed from 2000-2015 using satellite imagery. We used economic, demographic and field survey datasets to assess how regional and global market factors and local commodity crop decisions affect land use patterns. Our results show that oil palm is a major commodity crop expanding in this region, and that conversion is occurring primarily through expansion by medium-scale producers and local elites. Results also indicate that global and regional supply chain dynamics influence local land use decision making. This research contributes new information on land use patterns and dynamics in the Congo basin, an understudied region. More specifically, results from this research contribute information on recent trends of oil palm expansion in Cameroon that will be used in national land use planning strategies.

  1. Wavelength mismatch effect in electromagnetically induced absorption

    International Nuclear Information System (INIS)

    Bharti, Vineet; Wasan, Ajay; Natarajan, Vasant

    2016-01-01

    We present a theoretical investigation of the phenomenon of electromagnetically induced absorption (EIA) in a 4-level system consisting of vee and ladder subsystems. The four levels are coupled using one weak probe field, and two strong control fields. We consider an experimental realization using energy levels of Rb. This necessitates dealing with different conditions of wavelength mismatch—near-perfect match where all three wavelengths are approximately equal; partial mismatch where the wavelength of one control field is less than the other fields; and complete mismatch where all three wavelengths are unequal. We present probe absorption profiles with Doppler averaging at room temperature to account for experiments in a room temperature Rb vapor cell. Our analysis shows that EIA resonances can be studied using Rydberg states excited with diode lasers. - Highlights: • Wavelength mismatch effect is investigated in electromagnetically induced absorption (EIA). • An experimental realization of 4-level vee + ladder system using energy levels of rubidium atom is presented. • EIA resonances are studied under different conditions of wavelength mismatch. • Possibility of observation of EIA using Rydberg states excited with diode lasers.

  2. Wavelength mismatch effect in electromagnetically induced absorption

    Energy Technology Data Exchange (ETDEWEB)

    Bharti, Vineet [Department of Physics, Indian Institute of Science, Bangalore 560012 (India); Wasan, Ajay [Department of Physics, Indian Institute of Technology, Roorkee 247667 (India); Natarajan, Vasant [Department of Physics, Indian Institute of Science, Bangalore 560012 (India)

    2016-07-15

    We present a theoretical investigation of the phenomenon of electromagnetically induced absorption (EIA) in a 4-level system consisting of vee and ladder subsystems. The four levels are coupled using one weak probe field, and two strong control fields. We consider an experimental realization using energy levels of Rb. This necessitates dealing with different conditions of wavelength mismatch—near-perfect match where all three wavelengths are approximately equal; partial mismatch where the wavelength of one control field is less than the other fields; and complete mismatch where all three wavelengths are unequal. We present probe absorption profiles with Doppler averaging at room temperature to account for experiments in a room temperature Rb vapor cell. Our analysis shows that EIA resonances can be studied using Rydberg states excited with diode lasers. - Highlights: • Wavelength mismatch effect is investigated in electromagnetically induced absorption (EIA). • An experimental realization of 4-level vee + ladder system using energy levels of rubidium atom is presented. • EIA resonances are studied under different conditions of wavelength mismatch. • Possibility of observation of EIA using Rydberg states excited with diode lasers.

  3. Novel Nuclear Powered Photocatalytic Energy Conversion

    International Nuclear Information System (INIS)

    White, John R.; Kinsmen, Douglas; Regan, Thomas M.; Bobek, Leo M.

    2005-01-01

    The University of Massachusetts Lowell Radiation Laboratory (UMLRL) is involved in a comprehensive project to investigate a unique radiation sensing and energy conversion technology with applications for in-situ monitoring of spent nuclear fuel (SNF) during cask transport and storage. The technology makes use of the gamma photons emitted from the SNF as an inherent power source for driving a GPS-class transceiver that has the ability to verify the position and contents of the SNF cask. The power conversion process, which converts the gamma photon energy into electrical power, is based on a variation of the successful dye-sensitized solar cell (DSSC) design developed by Konarka Technologies, Inc. (KTI). In particular, the focus of the current research is to make direct use of the high-energy gamma photons emitted from SNF, coupled with a scintillator material to convert some of the incident gamma photons into photons having wavelengths within the visible region of the electromagnetic spectrum. The high-energy gammas from the SNF will generate some power directly via Compton scattering and the photoelectric effect, and the generated visible photons output from the scintillator material can also be converted to electrical power in a manner similar to that of a standard solar cell. Upon successful implementation of an energy conversion device based on this new gammavoltaic principle, this inherent power source could then be utilized within SNF storage casks to drive a tamper-proof, low-power, electronic detection/security monitoring system for the spent fuel. The current project has addressed several aspects associated with this new energy conversion concept, including the development of a base conceptual design for an inherent gamma-induced power conversion unit for SNF monitoring, the characterization of the radiation environment that can be expected within a typical SNF storage system, the initial evaluation of Konarka's base solar cell design, the design and

  4. Tunable, high-repetition-rate, dual-signal-wavelength femtosecond optical parametric oscillator based on BiB3O6

    Science.gov (United States)

    Meng, Xianghao; Wang, Zhaohua; Tian, Wenlong; Fang, Shaobo; Wei, Zhiyi

    2018-01-01

    We have demonstrated a high-repetition-rate tunable femtosecond dual-signal-wavelength optical parametric oscillator (OPO) based on BiB3O6 (BiBO) crystal, synchronously pumped by a frequency-doubled mode-locked Yb:KGW laser. The cavity is simple since no dispersion compensators are used in the cavity. The wavelength range of dual-signal is widely tunable from 710 to 1000 nm. Tuning is accomplished by rotating phase-matching angle of BiBO, and optimizing cavity length and output coupler. Using a 3.75 W pump laser, the maximum average dual-signal output power is 760 mW at 707 and 750 nm, leading to a conversion efficiency of 20.3% not taking into account the idler power. Our experimental results show a non-critical phase-matching configuration pumped by a high peak power laser source. The operation of the dual-signal benefits from the balance of phase matching and group velocity mismatching between the two signals.

  5. Experimental determination of beam quality conversion factors kQ in clinical photon beams using ferrous sulphate (Fricke) dosimetry

    International Nuclear Information System (INIS)

    Palm, A.; Mattsson, Olof

    2002-01-01

    The implementation of protocols based on absorbed dose to water standards requires beam quality conversion factors, k Q . Calculated values of k Q are available for ionization chambers used for reference dosimetry. Ideally, k Q should be experimentally determined at the same beam qualities as that of the user. In this work we measure k Q factors in clinical photon beams and compare them with calculated and measured values. Beam quality conversion factors are determined for clinical photon beams of nominal energies 4 MV, 6 MV, 15 MV, and 25 MV, for commonly used cylindrical ionization chambers. Twelve chambers of eight different types are used. For three of them, no experimental data have previously been available. The experimental procedure is based on measurements with ionization chambers and Fricke dosimetry in the reference beam ( 60 Co γ radiation) and in clinical linear accelerator beams. The k Q values determined in this work generally agree within 0.5% with previously reported experimental values both when %dd(10) x and TPR 20,10 are used for beam quality specification. The agreement with calculated data is generally within 0.5%, except for the 15 MV beam. For this beam the measured values are usually between 0.5% and 1% lower than the data taken from the TG-51 protocol or the TRS-398 code of practice. For three NE2571 chambers and three NE2581 chambers, the maximum observed deviation of individual k Q values is 0.2% and 0.4%, respectively

  6. The Wavelength Dependence of the Lunar Phase Curve as Seen by the LRO LAMP

    Science.gov (United States)

    Liu, Y.; Retherford, K. D.; Greathouse, T. K.; Hendrix, A. R.; Mandt, K.; Gladstone, R.; Cahill, J. T.; Egan, A.; Kaufmann, D. E.; Grava, C.; Pryor, W. R.

    2016-12-01

    The Lunar Reconnaissance Orbiter (LRO) Lyman Alpha Mapping Project (LAMP) provides global coverage of both nightside and dayside of the Moon in the far ultraviolet (FUV) wavelengths. The nightside observations use roughly uniform diffuse illumination sources from interplanetary medium Lyman-α sky glow and UV-bright stars so that traditional photometric corrections do not apply. In contrast, the dayside observations use sunlight as its illumination source where bidirectional reflectance is measured. The bidirectional reflectance is dependent on the incident, emission, and phase angles as well as the soil properties. Thus the comparisons of dayside mapping and nightside mapping techniques offer a method for cross-comparing the photometric correction factors because the observations are made under different lighting and viewing conditions. Specifically, the nightside data well constrain the single-scattering coefficient. We'll discuss the wavelength dependence of the lunar phase curve as seen by the LAMP instrument in dayside data. Our preliminary results indicate that the reflectance in the FUV wavelengths decreases with the increasing phase angles from 0° to 90°, similar to the phase curve in the UV-visible wavelengths as studied by Hapke et al. (2012) using LRO wide angle camera (WAC) data, among other visible-wavelength lunar studies. Particularly, we'll report how coherent backscattering and shadow hiding contribute to the opposition surge, given the fact that the albedo at FUV wavelengths is extremely low and thus multiple scattering is significantly less important. Finally, we'll report the derived Hapke parameters at FUV wavelengths for our study areas.

  7. Free-space wavelength-multiplexed optical scanner.

    Science.gov (United States)

    Yaqoob, Z; Rizvi, A A; Riza, N A

    2001-12-10

    A wavelength-multiplexed optical scanning scheme is proposed for deflecting a free-space optical beam by selection of the wavelength of the light incident on a wavelength-dispersive optical element. With fast tunable lasers or optical filters, this scanner features microsecond domain scan setting speeds and large- diameter apertures of several centimeters or more for subdegree angular scans. Analysis performed indicates an optimum scan range for a given diffraction order and grating period. Limitations include beam-spreading effects based on the varying scanner aperture sizes and the instantaneous information bandwidth of the data-carrying laser beam.

  8. Dynamic Sensor Interrogation Using Wavelength-Swept Laser with a Polygon-Scanner-Based Wavelength Filter

    Science.gov (United States)

    Kwon, Yong Seok; Ko, Myeong Ock; Jung, Mi Sun; Park, Ik Gon; Kim, Namje; Han, Sang-Pil; Ryu, Han-Cheol; Park, Kyung Hyun; Jeon, Min Yong

    2013-01-01

    We report a high-speed (∼2 kHz) dynamic multiplexed fiber Bragg grating (FBG) sensor interrogation using a wavelength-swept laser (WSL) with a polygon-scanner-based wavelength filter. The scanning frequency of the WSL is 18 kHz, and the 10 dB scanning bandwidth is more than 90 nm around a center wavelength of 1,540 nm. The output from the WSL is coupled into the multiplexed FBG array, which consists of five FBGs. The reflected Bragg wavelengths of the FBGs are 1,532.02 nm, 1,537.84 nm, 1,543.48 nm, 1,547.98 nm, and 1,553.06 nm, respectively. A dynamic periodic strain ranging from 500 Hz to 2 kHz is applied to one of the multiplexed FBGs, which is fixed on the stage of the piezoelectric transducer stack. Good dynamic performance of the FBGs and recording of their fast Fourier transform spectra have been successfully achieved with a measuring speed of 18 kHz. The signal-to-noise ratio and the bandwidth over the whole frequency span are determined to be more than 30 dB and around 10 Hz, respectively. We successfully obtained a real-time measurement of the abrupt change of the periodic strain. The dynamic FBG sensor interrogation system can be read out with a WSL for high-speed and high-sensitivity real-time measurement. PMID:23899934

  9. Wavelength Dependence of Solar Flare Irradiation and its Influence on the Thermosphere

    Science.gov (United States)

    Huang, Yanshi; Richmond, Arthur D.; Deng, Yue; Qian, L.; Solomon, S.; Chamberlin, P.

    2012-01-01

    The wavelength dependence of solar flare enhancement is one of the important factors determining how the Thermosphere-Ionosphere (T-I) system response to flares. To investigate the wavelength dependence of solar flare, the Flare Irradiance Spectral Model (FISM) has been run for 34 X-class flares. The results show that the percentage increases of solar irradiance at flare peak comparing to pre-flare condition have a clear wavelength dependence. In the wavelength range between 0 - 195 nm, it can vary from 1% to 10000%. The solar irradiance enhancement is largest ( 1000%) in the XUV range (0 - 25 nm), and is about 100% in EUV range (25 - 120 nm). The influence of different wavebands on the T-I system during the October 28th, 2003 flare (X17.2-class) has also been examined using the latest version of National Center for Atmospheric Research (NCAR) Thermosphere- Ionosphere-Electrodynamics General Circulation Model (TIE-GCM). While the globally integrated solar energy deposition is largest in the 0 - 14 nm waveband, the impact of solar irradiance enhancement on the thermosphere at 400 km is largest for 25 - 105 nm waveband. The effect of 122 - 195 nm is small in magnitude, but it decays slowly.

  10. Wavelength selectivity of on-axis surface plasmon laser filters

    International Nuclear Information System (INIS)

    Harmer, S W; Townsend, P D

    2002-01-01

    Excitation of surface plasmons on a metal substrate, via the attenuated total reflection method can theoretically offer preferential absorption of light at one particular wavelength, whilst reflecting the nearby spectrum. Normally this 'filtering' action is limited to removal of p-polarized light, and the acceptance angle of such a filtering device is very narrow, which limits practical applications, such as separation of fundamental and laser harmonics. The possibility of avoiding this angular precision is explored by considering the complex permittivity of metal composites. By using a two or more layer structure, as opposed to a single metal substrate, the acceptance angle of the device can be broadened, by a factor of about 15 times. An example is discussed for separation of the fundamental and harmonics from a Nd : YAG laser. Variants of the structure allow the design of an in-line transmission filter for the various wavelengths with sufficient angular tolerance to include focusing lenses. Avoidance of laser ablation of the metal is discussed

  11. Dual-Function Au@Y2O3:Eu3+ Smart Film for Enhanced Power Conversion Efficiency and Long-Term Stability of Perovskite Solar Cells.

    Science.gov (United States)

    Kim, Chang Woo; Eom, Tae Young; Yang, In Seok; Kim, Byung Su; Lee, Wan In; Kang, Yong Soo; Kang, Young Soo

    2017-07-28

    In the present study, a dual-functional smart film combining the effects of wavelength conversion and amplification of the converted wave by the localized surface plasmon resonance has been investigated for a perovskite solar cell. This dual-functional film, composed of Au nanoparticles coated on the surface of Y 2 O 3 :Eu 3+ phosphor (Au@Y 2 O 3 :Eu 3+ ) nanoparticle monolayer, enhances the solar energy conversion efficiency to electrical energy and long-term stability of photovoltaic cells. Coupling between the Y 2 O 3 :Eu 3+ phosphor monolayer and ultraviolet solar light induces the latter to be converted into visible light with a quantum yield above 80%. Concurrently, the Au nanoparticle monolayer on the phosphor nanoparticle monolayer amplifies the converted visible light by up to 170%. This synergy leads to an increased solar light energy conversion efficiency of perovskite solar cells. Simultaneously, the dual-function film suppresses the photodegradation of perovskite by UV light, resulting in long-term stability. Introducing the hybrid smart Au@Y 2 O 3 :Eu 3+ film in perovskite solar cells increases their overall solar-to-electrical energy conversion efficiency to 16.1% and enhances long-term stability, as compared to the value of 15.2% for standard perovskite solar cells. The synergism between the wavelength conversion effect of the phosphor nanoparticle monolayer and the wave amplification by the localized surface plasmon resonance of the Au nanoparticle monolayer in a perovskite solar cell is comparatively investigated, providing a viable strategy of broadening the solar spectrum utilization.

  12. Monte Carlo calculations of kQ, the beam quality conversion factor

    International Nuclear Information System (INIS)

    Muir, B. R.; Rogers, D. W. O.

    2010-01-01

    Purpose: To use EGSnrc Monte Carlo simulations to directly calculate beam quality conversion factors, k Q , for 32 cylindrical ionization chambers over a range of beam qualities and to quantify the effect of systematic uncertainties on Monte Carlo calculations of k Q . These factors are required to use the TG-51 or TRS-398 clinical dosimetry protocols for calibrating external radiotherapy beams. Methods: Ionization chambers are modeled either from blueprints or manufacturers' user's manuals. The dose-to-air in the chamber is calculated using the EGSnrc user-code egs c hamber using 11 different tabulated clinical photon spectra for the incident beams. The dose to a small volume of water is also calculated in the absence of the chamber at the midpoint of the chamber on its central axis. Using a simple equation, k Q is calculated from these quantities under the assumption that W/e is constant with energy and compared to TG-51 protocol and measured values. Results: Polynomial fits to the Monte Carlo calculated k Q factors as a function of beam quality expressed as %dd(10) x and TPR 10 20 are given for each ionization chamber. Differences are explained between Monte Carlo calculated values and values from the TG-51 protocol or calculated using the computer program used for TG-51 calculations. Systematic uncertainties in calculated k Q values are analyzed and amount to a maximum of one standard deviation uncertainty of 0.99% if one assumes that photon cross-section uncertainties are uncorrelated and 0.63% if they are assumed correlated. The largest components of the uncertainty are the constancy of W/e and the uncertainty in the cross-section for photons in water. Conclusions: It is now possible to calculate k Q directly using Monte Carlo simulations. Monte Carlo calculations for most ionization chambers give results which are comparable to TG-51 values. Discrepancies can be explained using individual Monte Carlo calculations of various correction factors which are more

  13. Metallic metasurfaces for high efficient polarization conversion control in transmission mode.

    Science.gov (United States)

    Li, Tong; Hu, Xiaobin; Chen, Huamin; Zhao, Chen; Xu, Yun; Wei, Xin; Song, Guofeng

    2017-10-02

    A high efficient broadband polarization converter is an important component in integrated miniaturized optical systems, but its performances is often restricted by the material structures, metallic metasurfaces for polarization control in transmission mode never achieved efficiency above 0.5. Herein, we theoretically demonstrate that metallic metasurfaces constructed by thick cross-shaped particles can realize a high efficient polarization transformation over a broadband. We investigated the resonant properties of designed matesurfaces and found that the interaction between double FP cavity resonances and double bulk magnetic resonances is the main reason to generate a high transmissivity over a broadband. In addition, through using four resonances effect and tuning the anisotropic optical response, we realized a high efficient (> 0.85) quarter-wave plate at the wavelength range from 1175nm to 1310nm and a high efficient (> 0.9) half-wave plate at the wavelength range from 1130nm to 1230nm. The proposed polarization converters may have many potential applications in integrated polarization conversion devices and optical data storage systems.

  14. Prediction of the methane conversion factor (Ym) for dairy cows on the basis of national farm data

    DEFF Research Database (Denmark)

    Hellwing, Anne Louise Frydendahl; Weisbjerg, Martin Riis; Brask, Maike

    2016-01-01

    Methane constitutes a significant loss of feed gross energy in ruminants, and there is an ongoing struggle for identifying feed and animal characteristics feasible for documentation of National Greenhouse Gas Inventories. The aim of the current study was to develop a model that predicts the methane...... and feed composition as variables, and one using yield of energy corrected milk and feed composition as variables. The methane conversion factor was significantly reduced with increased content of starch and fat in the ration, whereas neutral detergent fibre content surprisingly did not have a significant...

  15. Wavelength selection in traveling-wave convection in a fluid mixture

    International Nuclear Information System (INIS)

    Surko, C.M.; Eaton, K.D.; Baxter, G.W.; Iwata, K.

    1993-01-01

    The mechanisms by which a one-dimensional pattern of traveling waves changes wavelength (i.e. the Eckhaus instability) is studied in a binary fluid mixture. Propagating wavelength modulations develop when the Rayleigh number of the system is decreased below a wavelength-dependent threshold, commonly referred to as the Eckhaus boundary. These wavelength modulations increase in amplitude and narrow in spatial extent until they trigger the creation or annihilation of convection roll pairs and thereby change the average wavelength of the system. The authors find qualitatively different dynamics for wavelength-increasing events and wavelength-decreasing events; these differences are due to the strong wavelength dependence of the group velocity

  16. Pengaruh Citra Merek Dan Pengalaman Konsumen Terhadap Loyalitas Konsumen Sepatu Sneaker Merek Converse (Studi Kasus Pada Pengguna Sepatu Sneaker Merek Converse Di Kota Semarang)

    OpenAIRE

    Wicaksono, Aldo Dwi; Nugraha, Hari Susanta

    2017-01-01

    Every company expect to have a high customer loyalty. But, there is a Converse sneakers product sales degression in Semarang City based on observation that also indicate a degression in customer loyalty. Based on observation and theoritical study, that degression supected caused by low brand image factor and low customer experience factor. Therefore, the purpose of this research is to find out the impacts of brand image and cutomer experience towards Converse sneakers cutomer loyalty, both in...

  17. Identifying and Exploring Factors Affecting Embodied Conversational Agent Social Presence for Interpersonal Skills Training

    Science.gov (United States)

    Chuah, Joon Hao

    2013-01-01

    Embodied conversational agents (ECAs) have been used as virtual conversational partners in interpersonal skills training applications such as medical interviews, military decision making, and cultural training. Ideally, in interpersonal skills training users will perceive and treat the ECAs the same as they would real people. The perception and…

  18. Wavelength scaling of laser plasma coupling

    International Nuclear Information System (INIS)

    Kruer, W.L.

    1983-01-01

    The use of shorter wavelength laser light both enhances collisional absorption and reduces deleterious collective plasma effects. Coupling processes which can be important in reactor-size targets are briefly reviewed. Simple estimates are presented for the intensity-wavelength regime in which collisional absorption is high and collective effects are minimized

  19. Improved performance of P3HT:PCBM solar cells by both anode modification and short-wavelength energy utilization using Tb(aca)3phen

    International Nuclear Information System (INIS)

    Zhuo Zu-Liang; Wang Yong-Sheng; He Da-Wei; Fu Ming

    2014-01-01

    The performance of P3HT:PCBM solar cells was improved by anode modification using spin-coated Tb(aca) 3 phen ultrathin films. The modification of the Tb(aca) 3 phen ultrathin film between the indium tin oxide (ITO) anode and the PE-DOT:PSS layer resulted in a maximum power conversion efficiency (PCE) of 2.99% compared to 2.66% for the reference device, which was due to the increase in the short-circuit current density (J sc ). The PCE improvement could be attributed to the short-wavelength energy utilization and the optimized morphology of the active layers. Tb(aca) 3 phen with its strong down-conversion luminescence properties is suitable for the P3HT:PCBM blend active layer, and the absorption region of the ternary blend films is extended into the near ultraviolet region. Furthermore, the crystallization and the surface morphology of P3HT:PCBM films were improved with the Tb(aca) 3 phen ultrathin film. The ultraviolent—visible absorption spectra, atomic force microscope (AFM), and X-ray diffraction (XRD) of the films were investigated. Both anode modification and short-wavelength energy utilization using Tb(aca) 3 phen in P3HT:PCBM solar cells led to about a 12% PCE increase. (interdisciplinary physics and related areas of science and technology)

  20. Biophotonic markers of malignancy: Discriminating cancers using wavelength-specific biophotons

    Directory of Open Access Journals (Sweden)

    Nirosha J. Murugan

    2018-03-01

    Full Text Available Early detection is a critically important factor when successfully diagnosing and treating cancer. Whereas contemporary molecular techniques are capable of identifying biomarkers associated with cancer, surgical interventions are required to biopsy tissue. The common imaging alternative, positron-emission tomography (PET, involves the use of nuclear material which poses some risks. Novel, non-invasive techniques to assess the degree to which tissues express malignant properties are now needed. Recent developments in biophoton research have made it possible to discriminate cancerous cells from normal cells both in vitro and in vivo. The current study expands upon a growing body of literature where we classified and characterized malignant and non-malignant cell types according to their biophotonic activity. Using wavelength-exclusion filters, we demonstrate that ratios between infrared and ultraviolet photon emissions differentiate cancer and non-cancer cell types. Further, we identified photon sources associated with three filters (420-nm, 620-nm., and 950-nm which classified cancer and non-cancer cell types. The temporal increases in biophoton emission within these wavelength bandwidths is shown to be coupled with intrisitic biomolecular events using Cosic's resonant recognition model. Together, the findings suggest that the use of wavelength-exclusion filters in biophotonic measurement can be employed to detect cancer in vitro.

  1. Determinants of Urban Expansion and Agricultural Land Conversion in 25 EU Countries

    Science.gov (United States)

    Ustaoglu, Eda; Williams, Brendan

    2017-10-01

    Agricultural land conversion is resulting from ongoing complex interaction between the physical environment, policy settings and socio-economic factors. Case studies of the determinants of agricultural land conversion potentially contribute to the analysis of the main causes of land-use change. This can assist authorities and policy makers in understanding the relative importance of a wide range of factors on urban expansion and associated agricultural land-use change. This paper explores the determinants of agricultural land conversion to urban uses in the studied 25 European Union countries between 2000 and 2006. European-level as well as region-specific land-use changes are studied. The research is using the spatial data adapted from European Corine Land Cover maps of 2000 and 2006 and utilised other European sources regarding socio-economic, natural, geological, climate, and policy-related data. The differences in urbanisation processes observed in different regions in Europe emphasise the regional variations of urban conversion process of agricultural land use. This study identifies a combination of socio-economic drivers, policy-related factors, nature and location-based factors as key influences on agricultural land conversion processes in Europe. Specifically we found that the Common Agricultural Policy (CAP) subsidies were influential in curbing urbanisation and reducing agricultural land consumption.

  2. Determinants of Urban Expansion and Agricultural Land Conversion in 25 EU Countries.

    Science.gov (United States)

    Ustaoglu, Eda; Williams, Brendan

    2017-10-01

    Agricultural land conversion is resulting from ongoing complex interaction between the physical environment, policy settings and socio-economic factors. Case studies of the determinants of agricultural land conversion potentially contribute to the analysis of the main causes of land-use change. This can assist authorities and policy makers in understanding the relative importance of a wide range of factors on urban expansion and associated agricultural land-use change. This paper explores the determinants of agricultural land conversion to urban uses in the studied 25 European Union countries between 2000 and 2006. European-level as well as region-specific land-use changes are studied. The research is using the spatial data adapted from European Corine Land Cover maps of 2000 and 2006 and utilised other European sources regarding socio-economic, natural, geological, climate, and policy-related data. The differences in urbanisation processes observed in different regions in Europe emphasise the regional variations of urban conversion process of agricultural land use. This study identifies a combination of socio-economic drivers, policy-related factors, nature and location-based factors as key influences on agricultural land conversion processes in Europe. Specifically we found that the Common Agricultural Policy (CAP) subsidies were influential in curbing urbanisation and reducing agricultural land consumption.

  3. Systematic wavelength selection for improved multivariate spectral analysis

    Science.gov (United States)

    Thomas, Edward V.; Robinson, Mark R.; Haaland, David M.

    1995-01-01

    Methods and apparatus for determining in a biological material one or more unknown values of at least one known characteristic (e.g. the concentration of an analyte such as glucose in blood or the concentration of one or more blood gas parameters) with a model based on a set of samples with known values of the known characteristics and a multivariate algorithm using several wavelength subsets. The method includes selecting multiple wavelength subsets, from the electromagnetic spectral region appropriate for determining the known characteristic, for use by an algorithm wherein the selection of wavelength subsets improves the model's fitness of the determination for the unknown values of the known characteristic. The selection process utilizes multivariate search methods that select both predictive and synergistic wavelengths within the range of wavelengths utilized. The fitness of the wavelength subsets is determined by the fitness function F=.function.(cost, performance). The method includes the steps of: (1) using one or more applications of a genetic algorithm to produce one or more count spectra, with multiple count spectra then combined to produce a combined count spectrum; (2) smoothing the count spectrum; (3) selecting a threshold count from a count spectrum to select these wavelength subsets which optimize the fitness function; and (4) eliminating a portion of the selected wavelength subsets. The determination of the unknown values can be made: (1) noninvasively and in vivo; (2) invasively and in vivo; or (3) in vitro.

  4. Multi-Wavelength Photomagnetic Imaging for Oral Cancer

    Science.gov (United States)

    Marks, Michael

    In this study, a multi-wavelength Photomagnetic Imaging (PMI) system is developed and evaluated with experimental studies.. PMI measures temperature increases in samples illuminated by near-infrared light sources using magnetic resonance thermometry. A multiphysics solver combining light and heat transfer models the spatiotemporal distribution of the temperature change. The PMI system develop in this work uses three lasers of varying wavelength (785 nm, 808 nm, 860 nm) to heat the sample. By using multiple wavelengths, we enable the PMI system to quantify the relative concentrations of optical contrast in turbid media and monitor their distribution, at a higher resolution than conventional diffuse optical imaging. The data collected from agarose phantoms with multiple embedded contrast agents designed to simulate the optical properties of oxy- and deoxy-hemoglobin is presented. The reconstructed images demonstrate that multi-wavelength PMI can resolve this complex inclusion structure with high resolution and recover the concentration of each contrast agent with high quantitative accuracy. The modified multi-wavelength PMI system operates under the maximum skin exposure limits defined by the American National Standards Institute, to enable future clinical applications.

  5. An exploration of contextual dimensions impacting goals of care conversations in postgraduate medical education.

    Science.gov (United States)

    Roze des Ordons, Amanda L; Lockyer, Jocelyn; Hartwick, Michael; Sarti, Aimee; Ajjawi, Rola

    2016-03-21

    Postgraduate medical trainees are not well prepared difficult conversations about goals of care with patients and families in the acute care clinical setting. While contextual nuances within the workplace can impact communication, research to date has largely focused on individual communication skills. Our objective was to explore contextual factors that influence conversations between trainees and patients/families about goals of care in the acute care setting. We conducted an exploratory qualitative study involving five focus groups with Internal Medicine trainees (n = 20) and a series of interviews with clinical faculty (n = 11) within a single Canadian centre. Thematic framework analysis was applied to categorize the data and identify themes and subthemes. Challenges and factors enabling goals of care conversations emerged within individual, interpersonal and system dimensions. Challenges included inadequate preparation for these conversations, disconnection between trainees, faculty and patients, policies around documentation, the structure of postgraduate medical education, and resource limitations; these challenges led to missed opportunities, uncertainty and emotional distress. Enabling factors were awareness of the importance of goals of care conversations, support in these discussions, collaboration with colleagues, and educational initiatives enabling skill development; these factors have resulted in learning, appreciation, and an established foundation for future educational initiatives. Contextual factors impact how postgraduate medical trainees communicate with patients/families about goals of care. Attention to individual, interpersonal and system-related factors will be important in designing educational programs that help trainees develop the capacities needed for challenging conversations.

  6. Conversion and correction factors for historical measurements of iodine-131 in Hanford-area vegetation, 1945--1947

    International Nuclear Information System (INIS)

    Mart, E.I.; Denham, D.H.; Thiede, M.E.

    1993-12-01

    This report is a result of the Hanford Environmental Dose Reconstruction (HEDR) Project whose goal is to estimate the radiation dose that individuals could have received from emissions since 1944 at the U.S. Department of Energy's (DOE) Hanford Site near Richland, Washington. The HEDR Project is conducted by Battelle, Pacific Northwest Laboratories (BNW). One of the radionuclides emitted that would affect the radiation dose was iodine-131. This report describes in detail the reconstructed conversion and correction factors for historical measurements of iodine-131 in Hanford-area vegetation which was collected from the beginning of October 1945 through the end of December 1947

  7. Time to sputum conversion in multidrug-resistant tuberculosis patients in Armenia: retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Arax Hovhannesyan

    2012-06-01

    Full Text Available OBJECTIVE: To characterize time to sputum conversion among patients with multidrug resistant tuberculosis who were enrolled into second-line tuberculosis treatment program; to identify risk factors for delayed sputum conversion. DESIGN: Retrospective cohort study designed to identify the factors associated with sputum conversion. Survival analysis was performed using Kaplan-Meier estimator to compute estimates for median time to sputum conversion and Cox proportional hazards model to compute hazard ratios (HR. RESULTS: Sputum conversion from positive to negative was observed in 134 out of 195 cases (69%. Among these who converted the median time to conversion was 3.7 months. Factors independently associated with time to sputum conversion in the proportional hazards model were: male sex (HR=0.51, 95% CI 0.32-0.81, ofloxacin-resistant tuberculosis (HR = 0.45, 95% CI 0.26-0.78 and first period of recruitment into second-line treatment (HR= 0.69, 95% CI 0.47-1.01. CONCLUSION: Time to sputum conversion in patients with multidrug-resistant tuberculosis in Armenia was 5.8 months (range 0.5-17.0 months. High level of ofloxacin resistance was the main reason for compromised response to treatment. Patients with a poor resistance profile and males should be targeted with more aggressive initial therapy.

  8. Time to sputum conversion in multidrug-resistant tuberculosis patients in Armenia: retrospective cohort study

    Directory of Open Access Journals (Sweden)

    Arax Hovhannesyan

    2012-01-01

    Full Text Available OBJECTIVE: To characterize time to sputum conversion among patients with multidrug resistant tuberculosis who were enrolled into second-line tuberculosis treatment program; to identify risk factors for delayed sputum conversion. DESIGN: Retrospective cohort study designed to identify the factors associated with sputum conversion. Survival analysis was performed using Kaplan-Meier estimator to compute estimates for median time to sputum conversion and Cox proportional hazards model to compute hazard ratios (HR. RESULTS: Sputum conversion from positive to negative was observed in 134 out of 195 cases (69%. Among these who converted the median time to conversion was 3.7 months. Factors independently associated with time to sputum conversion in the proportional hazards model were: male sex (HR=0.51, 95% CI 0.32-0.81, ofloxacin-resistant tuberculosis (HR = 0.45, 95% CI 0.26-0.78 and first period of recruitment into second-line treatment (HR= 0.69, 95% CI 0.47-1.01. CONCLUSION: Time to sputum conversion in patients with multidrug-resistant tuberculosis in Armenia was 5.8 months (range 0.5- 17.0 months. High level of ofloxacin resistance was the main reason for compromised response to treatment. Patients with a poor resistance profile and males should be targeted with more aggressive initial therapy.

  9. Manipulating the wavelength-drift of a Tm laser for resonance enhancement in an intra-cavity pumped Ho laser.

    Science.gov (United States)

    Huang, Haizhou; Huang, Jianhong; Liu, Huagang; Li, Jinhui; Lin, Zixiong; Ge, Yan; Dai, Shutao; Deng, Jing; Lin, Wenxiong

    2018-03-05

    We demonstrate an enhancement mechanism and thermal model for intra-cavity pumped lasers, where resonance enhancement in intra-cavity pumped Ho laser was achieved by manipulating the wavelength-drift nature of the Tm laser for the first time. Optical conversion efficiency of 37.5% from an absorbed 785 nm diode laser to a Ho laser was obtained with a maximum output power of 7.51 W at 2122 nm, which is comparable to the conversion efficiency in 1.9 μm LD pumped Ho lasers. Meanwhile, more severe thermal effects in the Ho-doped gain medium than the Tm-doped one at high power operation were verified based on the built thermal model. This work benefits the design or evaluation of intra-cavity pumped lasers, and the resonance enhancement originated from the difference in reabsorption loss between stark levels at the lasing manifolds of quasi-three-level rare-earth ions has great interest to improve the existing intra-cavity pumped lasers or explore novel lasers.

  10. Conversion of carbon monoxide intensities tomolecular hydrogen abundances

    International Nuclear Information System (INIS)

    Kutner, M.L.; Leung, C.M.

    1985-01-01

    We present results of theoretical models (static spherical clouds with a microturbulent velocity field) to study the conversion of carbon monoxide (CO) line parameters into molecular hydrogen (H 2 ) column densities, N2. The three potential H 2 tracers that we investigate are the integrated 12 CO and 13 CO intensities, I 12 and I 13 , and the 13 CO LTE column density, N( 13 . We find that I 12 may be a reasonable tracer of N2 under conditions appropriate to the envelopes of giant molecular clouds and for studies involving cloud ensembles of different cloud sizes and velocity dispersions. However, it saturates under higher density conditions. It is important that empirical conversion factors be set using the types of objects to which they will be applied. For this reason, our analysis suggests that the conversion factor N2/I 12 for giant molecular clouds in the molecular ring of our galaxy may be a factor of 2 lower than the average used by many observers. This lower value is supported by some recent empirical determinations. The quantity I 13 is a good tracer of N2 over a wide range of densities but it is more sensitive to the actual 13 CO abundance. The quantity N( 13 is similar to I 13 as a good tracer of N2 except at low densities and temperatures. The ratio I 12 /I 13 may be used to delineate temperature and column density effects. Finally, we find a strong temperature dependence in the various conversion factors, with N2/I 12 scaling with gas temperature (T/sub k/ approximately as (T/sub k/)/sup -1.3/

  11. Direct Generation and Detection of Quantum Correlated Photons with 3.2 um Wavelength Spacing.

    Science.gov (United States)

    Sua, Yong Meng; Fan, Heng; Shahverdi, Amin; Chen, Jia-Yang; Huang, Yu-Ping

    2017-12-13

    Quantum correlated, highly non-degenerate photons can be used to synthesize disparate quantum nodes and link quantum processing over incompatible wavelengths, thereby constructing heterogeneous quantum systems for otherwise unattainable superior performance. Existing techniques for correlated photons have been concentrated in the visible and near-IR domains, with the photon pairs residing within one micron. Here, we demonstrate direct generation and detection of high-purity photon pairs at room temperature with 3.2 um wavelength spacing, one at 780 nm to match the rubidium D2 line, and the other at 3950 nm that falls in a transparent, low-scattering optical window for free space applications. The pairs are created via spontaneous parametric downconversion in a lithium niobate waveguide with specially designed geometry and periodic poling. The 780 nm photons are measured with a silicon avalanche photodiode, and the 3950 nm photons are measured with an upconversion photon detector using a similar waveguide, which attains 34% internal conversion efficiency. Quantum correlation measurement yields a high coincidence-to-accidental ratio of 54, which indicates the strong correlation with the extremely non-degenerate photon pairs. Our system bridges existing quantum technology to the challenging mid-IR regime, where unprecedented applications are expected in quantum metrology and sensing, quantum communications, medical diagnostics, and so on.

  12. Prediction of soil urea conversion and quantification of the importance degrees of influencing factors through a new combinatorial model based on cluster method and artificial neural network.

    Science.gov (United States)

    Lei, Tao; Guo, Xianghong; Sun, Xihuan; Ma, Juanjuan; Zhang, Shaowen; Zhang, Yong

    2018-05-01

    Quantitative prediction of soil urea conversion is crucial in determining the mechanism of nitrogen transformation and understanding the dynamics of soil nutrients. This study aimed to establish a combinatorial prediction model (MCA-F-ANN) for soil urea conversion and quantify the relative importance degrees (RIDs) of influencing factors with the MCA-F-ANN method. Data samples were obtained from laboratory culture experiments, and soil nitrogen content and physicochemical properties were measured every other day. Results showed that when MCA-F-ANN was used, the mean-absolute-percent error values of NH 4 + -N, NO 3 - -N, and NH 3 contents were 3.180%, 2.756%, and 3.656%, respectively. MCA-F-ANN predicted urea transformation under multi-factor coupling conditions more accurately than traditional models did. The RIDs of reaction time (RT), electrical conductivity (EC), temperature (T), pH, nitrogen application rate (F), and moisture content (W) were 32.2%-36.5%, 24.0%-28.9%, 12.8%-15.2%, 9.8%-12.5%, 7.8%-11.0%, and 3.5%-6.0%, respectively. The RIDs of the influencing factors in a descending order showed the pattern RT > EC > T > pH > F > W. RT and EC were the key factors in the urea conversion process. The prediction accuracy of urea transformation process was improved, and the RIDs of the influencing factors were quantified. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Wavelength stabilized multi-kW diode laser systems

    Science.gov (United States)

    Köhler, Bernd; Unger, Andreas; Kindervater, Tobias; Drovs, Simon; Wolf, Paul; Hubrich, Ralf; Beczkowiak, Anna; Auch, Stefan; Müntz, Holger; Biesenbach, Jens

    2015-03-01

    We report on wavelength stabilized high-power diode laser systems with enhanced spectral brightness by means of Volume Holographic Gratings. High-power diode laser modules typically have a relatively broad spectral width of about 3 to 6 nm. In addition the center wavelength shifts by changing the temperature and the driving current, which is obstructive for pumping applications with small absorption bandwidths. Wavelength stabilization of high-power diode laser systems is an important method to increase the efficiency of diode pumped solid-state lasers. It also enables power scaling by dense wavelength multiplexing. To ensure a wide locking range and efficient wavelength stabilization the parameters of the Volume Holographic Grating and the parameters of the diode laser bar have to be adapted carefully. Important parameters are the reflectivity of the Volume Holographic Grating, the reflectivity of the diode laser bar as well as its angular and spectral emission characteristics. In this paper we present detailed data on wavelength stabilized diode laser systems with and without fiber coupling in the spectral range from 634 nm up to 1533 nm. The maximum output power of 2.7 kW was measured for a fiber coupled system (1000 μm, NA 0.22), which was stabilized at a wavelength of 969 nm with a spectral width of only 0.6 nm (90% value). Another example is a narrow line-width diode laser stack, which was stabilized at a wavelength of 1533 nm with a spectral bandwidth below 1 nm and an output power of 835 W.

  14. Dissecting variation in biomass conversion factors across China's forests: implications for biomass and carbon accounting.

    Science.gov (United States)

    Luo, Yunjian; Zhang, Xiaoquan; Wang, Xiaoke; Ren, Yin

    2014-01-01

    Biomass conversion factors (BCFs, defined as the ratios of tree components (i.e. stem, branch, foliage and root), as well as aboveground and whole biomass of trees to growing stock volume, Mg m-3) are considered as important parameters in large-scale forest biomass carbon estimation. To date, knowledge of possible sources of the variation in BCFs is still limited at large scales. Using our compiled forest biomass dataset of China, we presented forest type-specific values of BCFs, and examined the variation in BCFs in relation to forest type, stand development and environmental factors (climate and soil fertility). BCFs exhibited remarkable variation across forest types, and also were significantly related to stand development (especially growing stock volume). BCFs (except Stem BCF) had significant relationships with mean annual temperature (MAT) and mean annual precipitation (MAP) (Pforest carbon estimates, we should apply values of BCFs for a specified forest type, and also consider climatic and edaphic effects, especially climatic effect, in developing predictive models of BCFs (except Stem BCF).

  15. Structured light generation by magnetic metamaterial half-wave plates at visible wavelength

    Science.gov (United States)

    Zeng, Jinwei; Luk, Ting S.; Gao, Jie; Yang, Xiaodong

    2017-12-01

    Metamaterial or metasurface unit cells functioning as half-wave plates play an essential role for realizing ideal Pancharatnam-Berry phase optical elements capable of tailoring light phase and polarization as desired. Complex light beam manipulation through these metamaterials or metasurfaces unveils new dimensions of light-matter interactions for many advances in diffraction engineering, beam shaping, structuring light, and holography. However, the realization of metamaterial or metasurface half-wave plates in visible spectrum range is still challenging mainly due to its specific requirements of strong phase anisotropy with amplitude isotropy in subwavelength scale. Here, we propose magnetic metamaterial structures which can simultaneously exploit the electric field and magnetic field of light for achieving the nanoscale half-wave plates at visible wavelength. We design and demonstrate the magnetic metamaterial half-wave plates in linear grating patterns with high polarization conversion purity in a deep subwavelength thickness. Then, we characterize the equivalent magnetic metamaterial half-wave plates in cylindrical coordinate as concentric-ring grating patterns, which act like an azimuthal half-wave plate and accordingly exhibit spatially inhomogeneous polarization and phase manipulations including spin-to-orbital angular momentum conversion and vector beam generation. Our results show potentials for realizing on-chip beam converters, compact holograms, and many other metamaterial devices for structured light beam generation, polarization control, and wavefront manipulation.

  16. Wavelength sweepable laser source

    DEFF Research Database (Denmark)

    2014-01-01

    Wavelength sweepable laser source is disclosed, wherein the laser source is a semiconductor laser source adapted for generating laser light at a lasing wavelength. The laser source comprises a substrate, a first reflector, and a second reflector. The first and second reflector together defines...... and having a rest position, the second reflector and suspension together defining a microelectromechanical MEMS oscillator. The MEMS oscillator has a resonance frequency and is adapted for oscillating the second reflector on either side of the rest position.; The laser source further comprises electrical...... connections adapted for applying an electric field to the MEMS oscillator. Furthermore, a laser source system and a method of use of the laser source are disclosed....

  17. Exploring the wavelength range of InP/AlGaInP QDs and application to dual-state lasing

    International Nuclear Information System (INIS)

    Shutts, Samuel; Elliott, Stella N; Smowton, Peter M; Krysa, Andrey B

    2015-01-01

    We explore the accessible wavelength range offered by InP/AlGaInP quantum dots (QD)s grown by metal–organic vapour phase epitaxy and explain how changes in growth temperature and wafer design can be used to influence the transition energy of the dot states and improve the performance of edge-emitting lasers. The self assembly growth method of these structures creates a multi-modal distribution of inhomogeneously broadened dot sizes, and via the effects of state-filling, allows access to a large range of lasing wavelengths. By characterising the optical properties of these dots, we have designed and demonstrated dual-wavelength lasers which operate at various difference-wavelengths between 8 and 63 nm. We show that the nature of QDs allows the difference-wavelength to be tuned by altering the operating temperature at a rate of up to 0.12 nm K −1 and we investigate the factors affecting intensity stability of the competing modes. (invited article)

  18. Effects of morphology and wavelength on the measurement accuracy of soot volume fraction by laser extinction

    Science.gov (United States)

    Wang, Ya-fei; Huang, Qun-xing; Wang, Fei; Chi, Yong; Yan, Jian-hua

    2018-01-01

    A novel method to evaluate the quantitative effects of soot morphology and incident wavelength on the measurement accuracy of soot volume fraction, by the laser extinction (LE) technique is proposed in this paper. The results indicate that the traditional LE technique would overestimate soot volume fraction if the effects of morphology and wavelength are not considered. Before the agglomeration of isolated soot primary particles, the overestimation of the LE technique is in the range of 2-20%, and rises with increasing primary particle diameter and with decreasing incident wavelength. When isolated primary particles are agglomerated into fractal soot aggregates, the overestimation would exceed 30%, and rise with increasing primary particle number per soot aggregate, fractal dimension and fractal prefactor and with decreasing incident wavelength to a maximum value of 55%. Finally, based on these results above, the existing formula of the LE technique gets modified, and the modification factor is 0.65-0.77.

  19. Wavelength standards in the infrared

    CERN Document Server

    Rao, KN

    2012-01-01

    Wavelength Standards in the Infrared is a compilation of wavelength standards suitable for use with high-resolution infrared spectrographs, including both emission and absorption standards. The book presents atomic line emission standards of argon, krypton, neon, and xenon. These atomic line emission standards are from the deliberations of Commission 14 of the International Astronomical Union, which is the recognized authority for such standards. The text also explains the techniques employed in determining spectral positions in the infrared. One of the techniques used includes the grating con

  20. Analysis of calibration-free wavelength-scanned wavelength modulation spectroscopy for practical gas sensing using tunable diode lasers

    Science.gov (United States)

    Sun, K.; Chao, X.; Sur, R.; Goldenstein, C. S.; Jeffries, J. B.; Hanson, R. K.

    2013-12-01

    A novel strategy has been developed for analysis of wavelength-scanned, wavelength modulation spectroscopy (WMS) with tunable diode lasers (TDLs). The method simulates WMS signals to compare with measurements to determine gas properties (e.g., temperature, pressure and concentration of the absorbing species). Injection-current-tuned TDLs have simultaneous wavelength and intensity variation, which severely complicates the Fourier expansion of the simulated WMS signal into harmonics of the modulation frequency (fm). The new method differs from previous WMS analysis strategies in two significant ways: (1) the measured laser intensity is used to simulate the transmitted laser intensity and (2) digital lock-in and low-pass filter software is used to expand both simulated and measured transmitted laser intensities into harmonics of the modulation frequency, WMS-nfm (n = 1, 2, 3,…), avoiding the need for an analytic model of intensity modulation or Fourier expansion of the simulated WMS harmonics. This analysis scheme is valid at any optical depth, modulation index, and at all values of scanned-laser wavelength. The method is demonstrated and validated with WMS of H2O dilute in air (1 atm, 296 K, near 1392 nm). WMS-nfm harmonics for n = 1 to 6 are extracted and the simulation and measurements are found in good agreement for the entire WMS lineshape. The use of 1f-normalization strategies to realize calibration-free wavelength-scanned WMS is also discussed.

  1. Performance evaluation of distributed wavelength assignment in WDM optical networks

    Science.gov (United States)

    Hashiguchi, Tomohiro; Wang, Xi; Morikawa, Hiroyuki; Aoyama, Tomonori

    2004-04-01

    In WDM wavelength routed networks, prior to a data transfer, a call setup procedure is required to reserve a wavelength path between the source-destination node pairs. A distributed approach to a connection setup can achieve a very high speed, while improving the reliability and reducing the implementation cost of the networks. However, along with many advantages, several major challenges have been posed by the distributed scheme in how the management and allocation of wavelength could be efficiently carried out. In this thesis, we apply a distributed wavelength assignment algorithm named priority based wavelength assignment (PWA) that was originally proposed for the use in burst switched optical networks to the problem of reserving wavelengths of path reservation protocols in the distributed control optical networks. Instead of assigning wavelengths randomly, this approach lets each node select the "safest" wavelengths based on the information of wavelength utilization history, thus unnecessary future contention is prevented. The simulation results presented in this paper show that the proposed protocol can enhance the performance of the system without introducing any apparent drawbacks.

  2. Direct writing of sub-wavelength ripples on silicon using femtosecond laser at high repetition rate

    International Nuclear Information System (INIS)

    Xie, Changxin; Li, Xiaohong; Liu, Kaijun; Zhu, Min; Qiu, Rong; Zhou, Qiang

    2016-01-01

    Graphical abstract: - Highlights: • The NSRs and DSRs are obtained on silicon surface. • With increasing direct writing speed, the NSRs suddenly changes and becomes the DSRs. • We develop a Sipe–Drude interference theory by considering the thermal excitation. - Abstract: The near sub-wavelength and deep sub-wavelength ripples on monocrystalline silicon were formed in air by using linearly polarized and high repetition rate femtosecond laser pulses (f = 76 MHz, λ = 800 nm, τ = 50 fs). The effects of laser pulse energy, direct writing speed and laser polarization on silicon surface morphology are studied. When the laser pulse energy is 2 nJ/pulse and the direct writing speed varies from 10 to 25 mm/s, the near sub-wavelength ripples (NSRs) with orientation perpendicular to the laser polarization are generated. While the direct writing speed reaches 30 mm/s, the direction of the obtained deep sub-wavelength ripples (DSRs) suddenly changes and becomes parallel to the laser polarization, rarely reported so far for femtosecond laser irradiation of silicon. Meanwhile, we extend the Sipe–Drude interference theory by considering the thermal excitation, and numerically calculate the efficacy factor for silicon irradiated by femtosecond laser pulses. The revised Sipe–Drude interference theoretical results show good agreement with the periods and orientations of sub-wavelength ripples.

  3. Entanglement and nonclassicality in four-mode Gaussian states generated via parametric down-conversion and frequency up-conversion

    Czech Academy of Sciences Publication Activity Database

    Arkhipov, Ie.I.; Peřina Jr., J.; Haderka, Ondřej; Allevi, A.; Bondani, M.

    2016-01-01

    Roč. 6, Sep (2016), 1-12, č. článku 33802. ISSN 2045-2322 Institutional support: RVO:68378271 Keywords : four-mode Gaussian states * parametric down-conversion Subject RIV: BH - Optics, Masers, Lasers Impact factor: 4.259, year: 2016

  4. Impact of beacon wavelength on phase-compensation performance

    Science.gov (United States)

    Enterline, Allison A.; Spencer, Mark F.; Burrell, Derek J.; Brennan, Terry J.

    2017-09-01

    This study evaluates the effects of beacon-wavelength mismatch on phase-compensation performance. In general, beacon-wavelength mismatch occurs at the system level because the beacon-illuminator laser (BIL) and high-energy laser (HEL) are often at different wavelengths. Such is the case, for example, when using an aperture sharing element to isolate the beam-control sensor suite from the blinding nature of the HEL. With that said, this study uses the WavePlex Toolbox in MATLAB® to model ideal spherical wave propagation through various atmospheric-turbulence conditions. To quantify phase-compensation performance, we also model a nominal adaptive-optics (AO) system. We achieve correction from a Shack-Hartmann wavefront sensor and continuous-face-sheet deformable mirror using a least-squares phase reconstruction algorithm in the Fried geometry and a leaky integrator control law. To this end, we plot the power in the bucket metric as a function of BIL-HEL wavelength difference. Our initial results show that positive BIL-HEL wavelength differences achieve better phase compensation performance compared to negative BIL-HEL wavelength differences (i.e., red BILs outperform blue BILs). This outcome is consistent with past results.

  5. The impact of early trauma and recent life-events on symptom severity in patients with conversion disorder

    NARCIS (Netherlands)

    Roelofs, K.; Spinhoven, P.; Sandijck, P.; Moene, F.C.; Hoogduin, C.A.L.

    2005-01-01

    Although the presence of psychological stress factors in the evolution of conversion symptoms forms an important criterion for the DSM-IV diagnosis of conversion disorder, little is known about the nature and timing of these stress factors. Fifty-four patients with conversion disorder and 50 control

  6. Temperature Characteristics of Monolithically Integrated Wavelength-Selectable Light Sources

    International Nuclear Information System (INIS)

    Han Liang-Shun; Zhu Hong-Liang; Zhang Can; Ma Li; Liang Song; Wang Wei

    2013-01-01

    The temperature characteristics of monolithically integrated wavelength-selectable light sources are experimentally investigated. The wavelength-selectable light sources consist of four distributed feedback (DFB) lasers, a multimode interferometer coupler, and a semiconductor optical amplifier. The oscillating wavelength of the DFB laser could be modulated by adjusting the device operating temperature. A wavelength range covering over 8.0nm is obtained with stable single-mode operation by selecting the appropriate laser and chip temperature. The thermal crosstalk caused by the lateral heat spreading between lasers operating simultaneously is evaluated by oscillating-wavelength shift. The thermal crosstalk approximately decreases exponentially as the increasing distance between lasers

  7. Mode conversion in hybrid optical fiber coupler

    Science.gov (United States)

    Stasiewicz, Karol A.; Marc, P.; Jaroszewicz, Leszek R.

    2012-04-01

    Designing of all in-line fiber optic systems with a supercontinuum light source gives some issues. The use of a standard single mode fiber (SMF) as an input do not secure single mode transmission in full wavelength range. In the paper, the experimental results of the tested hybrid fiber optic coupler were presented. It was manufactured by fusing a standard single mode fiber (SMF28) and a photonic crystal fiber (PCF). The fabrication process is based on the standard fused biconical taper technique. Two types of large mode area fibers (LMA8 and LAM10 NKT Photonics) with different air holes arrangements were used as the photonic crystal fiber. Spectral characteristics within the range of 800 nm - 1700 nm were presented. All process was optimized to obtain a mode conversion between SMF and PCF and to reach a single mode transmission in the PCF output of the coupler.

  8. Sensitivity Enhancement in Low Cutoff Wavelength Long-Period Fiber Gratings by Cladding Diameter Reduction

    Directory of Open Access Journals (Sweden)

    Ignacio Del Villar

    2017-09-01

    Full Text Available The diameter of long-period fiber gratings (LPFGs fabricated in optical fibers with a low cutoff wavelength was be reduced by hydrofluoric acid etching, enhancing the sensitivity to refractive index by more than a factor of 3, to 2611 nm/refractive index unit in the range from 1.333 to 1.4278. The grating period selected for the LPFGs allowed access to the dispersion turning point at wavelengths close to the visible range of the optical spectrum, where optical equipment is less expensive. As an example of an application, a pH sensor based on the deposition of a polymeric coating was analyzed in two situations: with an LPFG without diameter reduction and with an LPFG with diameter reduction. Again, a sensitivity increase of a factor of near 3 was obtained, demonstrating the ability of this method to enhance the sensitivity of thin-film-coated LPFG chemical sensors.

  9. Sensitivity Enhancement in Low Cutoff Wavelength Long-Period Fiber Gratings by Cladding Diameter Reduction.

    Science.gov (United States)

    Del Villar, Ignacio; Partridge, Matthew; Rodriguez, Wenceslao Eduardo; Fuentes, Omar; Socorro, Abian Bentor; Diaz, Silvia; Corres, Jesus Maria; James, Stephen Wayne; Tatam, Ralph Peter

    2017-09-13

    The diameter of long-period fiber gratings (LPFGs) fabricated in optical fibers with a low cutoff wavelength was be reduced by hydrofluoric acid etching, enhancing the sensitivity to refractive index by more than a factor of 3, to 2611 nm/refractive index unit in the range from 1.333 to 1.4278. The grating period selected for the LPFGs allowed access to the dispersion turning point at wavelengths close to the visible range of the optical spectrum, where optical equipment is less expensive. As an example of an application, a pH sensor based on the deposition of a polymeric coating was analyzed in two situations: with an LPFG without diameter reduction and with an LPFG with diameter reduction. Again, a sensitivity increase of a factor of near 3 was obtained, demonstrating the ability of this method to enhance the sensitivity of thin-film-coated LPFG chemical sensors.

  10. THE METALLICITY DEPENDENCE OF THE CO {yields} H{sub 2} CONVERSION FACTOR IN z {>=} 1 STAR-FORMING GALAXIES

    Energy Technology Data Exchange (ETDEWEB)

    Genzel, R.; Tacconi, L. J.; Schreiber, N. M. Foerster; Gracia-Carpio, J.; Lutz, D.; Saintonge, A. [Max-Planck-Institut fuer extraterrestrische Physik (MPE), Giessenbachstr. 1, 85748 Garching (Germany); Combes, F. [Observatoire de Paris, LERMA, CNRS, 61 Av. de l' Observatoire, F-75014 Paris (France); Bolatto, A. [Department of Astronomy, University of Maryland, College Park, MD 20742-2421 (United States); Neri, R.; Cox, P. [IRAM, 300 Rue de la Piscine, 38406 St. Martin d' Heres, Grenoble (France); Sternberg, A. [Sackler School of Physics and Astronomy, Tel Aviv University, Tel Aviv 69978 (Israel); Cooper, M. C. [Department of Physics and Astronomy, Frederick Reines Hall, University of California, Irvine, CA 92697-4575 (United States); Bouche, N. [Department of Physics, University of California, Santa Barbara, Broida Hall, Santa Barbara, CA 93106 (United States); Bournaud, F. [Service d' Astrophysique, DAPNIA, CEA/Saclay, F-91191 Gif-sur-Yvette Cedex (France); Burkert, A. [Universitaetssternwarte der Ludwig-Maximiliansuniversitaet, Scheinerstr. 1, D-81679 Muenchen (Germany); Comerford, J. [Department of Astronomy and McDonald Observatory, 1 University Station, C1402 Austin, TX 78712-0259 (United States); Davis, M.; Newman, S. [Department of Astronomy, Campbell Hall, University of California, Berkeley, CA 94720 (United States); Garcia-Burillo, S. [Observatorio Astronomico Nacional-OAN, Apartado 1143, 28800 Alcala de Henares- Madrid (Spain); Naab, T., E-mail: genzel@mpe.mpg.de, E-mail: linda@mpe.mpg.de [Max-Planck Institut fuer Astrophysik (MPA), Karl Schwarzschildstrasse 1, D-85748 Garching (Germany); and others

    2012-02-10

    We use the first systematic samples of CO millimeter emission in z {>=} 1 'main-sequence' star-forming galaxies to study the metallicity dependence of the conversion factor {alpha}{sub CO,} from CO line luminosity to molecular gas mass. The molecular gas depletion rate inferred from the ratio of the star formation rate (SFR) to CO luminosity, is {approx}1 Gyr{sup -1} for near-solar metallicity galaxies with stellar masses above M{sub S} {approx} 10{sup 11} M{sub Sun }. In this regime, the depletion rate does not vary more than a factor of two to three as a function of molecular gas surface density or redshift between z {approx} 0 and 2. Below M{sub S} the depletion rate increases rapidly with decreasing metallicity. We argue that this trend is not caused by starburst events, by changes in the physical parameters of the molecular clouds, or by the impact of the fundamental-metallicity-SFR-stellar mass relation. A more probable explanation is that the conversion factor is metallicity dependent and that star formation can occur in 'CO-dark' gas. The trend is also expected theoretically from the effect of enhanced photodissociation of CO by ultraviolet radiation at low metallicity. From the available z {approx} 0 and z {approx} 1-3 samples we constrain the slope of the log({alpha}{sub CO})-log (metallicity) relation to range between -1 and -2, fairly insensitive to the assumed slope of the gas-SFR relation. Because of the lower metallicities near the peak of the galaxy formation activity at z {approx} 1-2 compared to z {approx} 0, we suggest that molecular gas masses estimated from CO luminosities have to be substantially corrected upward for galaxies below M{sub S}.

  11. Role of different factors as preoperative predictors of conversion of laparoscopic cholecystectomy to open cholecystectomy

    Directory of Open Access Journals (Sweden)

    Ramlah Ghazanfar

    2017-01-01

    Full Text Available Aim: Laparoscopic cholecystectomy has become the gold standard for the treatment of gallstones. Background: The objective of our study was to identify the preoperative predictors of conversion of laparoscopic cholecystectomy into open cholecystectomy. Materials and Methods: We carried out a cross-sectional study in the Surgical Unit 1, Holy Family Hospital, Rawalpindi, from September 2016 to February 2017. All patients undergoing laparoscopic cholecystectomy were included in the study. Patients undergoing open cholecystectomy due to the presence of contraindication to laparoscopic cholecystectomy or patients in which laparoscopic cholecystectomy was a part of some other laparoscopic intervention were not included in the study. SPSS version 21 was used to analyze the data. Results: The overall mean age of the patients was 43.67 ± 13.54 years. The male patients were significantly older as compared to the female patients. The conversion rate was higher in patients who had an elevated total leukocyte count and alanine aminotransferase before the operation (P < 0.05. The rate of conversion was significantly higher in male patients aged ≥50 years (P < 0.05. Difficulty in the dissection of the triangle of Calot, difficulty in dissecting the gallbladder fossa, bleeding in gallbladder fossa, presence of duodenal fistula, and autolyzed gangrenous gallbladder were the reasons for the conversion to open cholecystectomy. Conclusion: The rate of conversion of laparoscopic cholecystectomy to open cholecystectomy was found to be 5%. Male patients aged ≥50 years, acalculous acute cholecystitis, acute cholecystitis, elevated preoperative total leukocyte count, and alanine aminotransferase levels were found to be significant predictors of conversion to open cholecystectomy.

  12. A Multi-Wavelength IR Laser for Space Applications

    Science.gov (United States)

    Li, Steven X.; Yu, Anthony W.; Sun, Xiaoli; Fahey, Molly E.; Numata, Kenji; Krainak, Michael A.

    2017-01-01

    We present a laser technology development with space flight heritage to generate laser wavelengths in the near- to mid-infrared (NIR to MIR) for space lidar applications. Integrating an optical parametric crystal to the LOLA (Lunar Orbiter Laser Altimeter) laser transmitter design affords selective laser wavelengths from NIR to MIR that are not easily obtainable from traditional diode pumped solid-state lasers. By replacing the output coupler of the LOLA laser with a properly designed parametric crystal, we successfully demonstrated a monolithic intra-cavity optical parametric oscillator (iOPO) laser based on all high technology readiness level (TRL) subsystems and components. Several desired wavelengths have been generated including 2.1 microns, 2.7 microns and 3.4 microns. This laser can also be used in trace-gas remote sensing, as many molecules possess their unique vibrational transitions in NIR to MIR wavelength region, as well as in time-of-flight mass spectrometer where desorption of samples using MIR laser wavelengths have been successfully demonstrated.

  13. Optimal wavelength band clustering for multispectral iris recognition.

    Science.gov (United States)

    Gong, Yazhuo; Zhang, David; Shi, Pengfei; Yan, Jingqi

    2012-07-01

    This work explores the possibility of clustering spectral wavelengths based on the maximum dissimilarity of iris textures. The eventual goal is to determine how many bands of spectral wavelengths will be enough for iris multispectral fusion and to find these bands that will provide higher performance of iris multispectral recognition. A multispectral acquisition system was first designed for imaging the iris at narrow spectral bands in the range of 420 to 940 nm. Next, a set of 60 human iris images that correspond to the right and left eyes of 30 different subjects were acquired for an analysis. Finally, we determined that 3 clusters were enough to represent the 10 feature bands of spectral wavelengths using the agglomerative clustering based on two-dimensional principal component analysis. The experimental results suggest (1) the number, center, and composition of clusters of spectral wavelengths and (2) the higher performance of iris multispectral recognition based on a three wavelengths-bands fusion.

  14. In-vacuum long-wavelength macromolecular crystallography.

    Science.gov (United States)

    Wagner, Armin; Duman, Ramona; Henderson, Keith; Mykhaylyk, Vitaliy

    2016-03-01

    Structure solution based on the weak anomalous signal from native (protein and DNA) crystals is increasingly being attempted as part of synchrotron experiments. Maximizing the measurable anomalous signal by collecting diffraction data at longer wavelengths presents a series of technical challenges caused by the increased absorption of X-rays and larger diffraction angles. A new beamline at Diamond Light Source has been built specifically for collecting data at wavelengths beyond the capability of other synchrotron macromolecular crystallography beamlines. Here, the theoretical considerations in support of the long-wavelength beamline are outlined and the in-vacuum design of the endstation is discussed, as well as other hardware features aimed at enhancing the accuracy of the diffraction data. The first commissioning results, representing the first in-vacuum protein structure solution, demonstrate the promising potential of the beamline.

  15. Wind energy conversion system

    Science.gov (United States)

    Longrigg, Paul

    1987-01-01

    The wind energy conversion system includes a wind machine having a propeller connected to a generator of electric power, the propeller rotating the generator in response to force of an incident wind. The generator converts the power of the wind to electric power for use by an electric load. Circuitry for varying the duty factor of the generator output power is connected between the generator and the load to thereby alter a loading of the generator and the propeller by the electric load. Wind speed is sensed electro-optically to provide data of wind speed upwind of the propeller, to thereby permit tip speed ratio circuitry to operate the power control circuitry and thereby optimize the tip speed ratio by varying the loading of the propeller. Accordingly, the efficiency of the wind energy conversion system is maximized.

  16. Multiple wavelength X-ray monochromators

    International Nuclear Information System (INIS)

    Steinmeyer, P.A.

    1992-01-01

    An improved apparatus and method is provided for separating input x-ray radiation containing first and second x-ray wavelengths into spatially separate first and second output radiation which contain the first and second x-ray wavelengths, respectively. The apparatus includes a crystalline diffractor which includes a first set of parallel crystal planes, where each of the planes is spaced a predetermined first distance from one another. The crystalline diffractor also includes a second set of parallel crystal planes inclined at an angle with respect to the first set of crystal planes where each of the planes of the second set of parallel crystal planes is spaced a predetermined second distance from one another. In one embodiment, the crystalline diffractor is comprised of a single crystal. In a second embodiment, the crystalline diffractor is comprised of a stack of two crystals. In a third embodiment, the crystalline diffractor includes a single crystal that is bent for focusing the separate first and second output x-ray radiation wavelengths into separate focal points. 3 figs

  17. Two-mode PLC-based mode multi/demultiplexer for mode and wavelength division multiplexed transmission.

    Science.gov (United States)

    Hanzawa, Nobutomo; Saitoh, Kuimasa; Sakamoto, Taiji; Matsui, Takashi; Tsujikawa, Kyozo; Koshiba, Masanori; Yamamoto, Fumihiko

    2013-11-04

    We proposed a PLC-based mode multi/demultiplexer (MUX/DEMUX) with an asymmetric parallel waveguide for mode division multiplexed (MDM) transmission. The mode MUX/DEMUX including a mode conversion function with an asymmetric parallel waveguide can be realized by matching the effective indices of the LP(01) and LP(11) modes of two waveguides. We report the design of a mode MUX/DEMUX that can support C-band WDM-MDM transmission. The fabricated mode MUX/DEMUX realized a low insertion loss of less than 1.3 dB and high a mode extinction ratio that exceeded 15 dB. We used the fabricated mode MUX/DEMUX to achieve a successful 2 mode x 4 wavelength x 10 Gbps transmission over a 9 km two-mode fiber with a penalty of less than 1 dB.

  18. Uranium conversion

    International Nuclear Information System (INIS)

    Oliver, Lena; Peterson, Jenny; Wilhelmsen, Katarina

    2006-03-01

    FOI, has performed a study on uranium conversion processes that are of importance in the production of different uranium compounds in the nuclear industry. The same conversion processes are of interest both when production of nuclear fuel and production of fissile material for nuclear weapons are considered. Countries that have nuclear weapons ambitions, with the intention to produce highly enriched uranium for weapons purposes, need some degree of uranium conversion capability depending on the uranium feed material available. This report describes the processes that are needed from uranium mining and milling to the different conversion processes for converting uranium ore concentrate to uranium hexafluoride. Uranium hexafluoride is the uranium compound used in most enrichment facilities. The processes needed to produce uranium dioxide for use in nuclear fuel and the processes needed to convert different uranium compounds to uranium metal - the form of uranium that is used in a nuclear weapon - are also presented. The production of uranium ore concentrate from uranium ore is included since uranium ore concentrate is the feed material required for a uranium conversion facility. Both the chemistry and principles or the different uranium conversion processes and the equipment needed in the processes are described. Since most of the equipment that is used in a uranium conversion facility is similar to that used in conventional chemical industry, it is difficult to determine if certain equipment is considered for uranium conversion or not. However, the chemical conversion processes where UF 6 and UF 4 are present require equipment that is made of corrosion resistant material

  19. High conversion burner type reactor

    International Nuclear Information System (INIS)

    Higuchi, Shin-ichi; Kawashima, Masatoshi

    1987-01-01

    Purpose: To simply and easily dismantle and reassemble densified fuel assemblies taken out of a high conversion ratio area thereby improve the neutron and fuel economy. Constitution: The burner portion for the purpose of fuel combustion is divided into a first burner region in adjacent with the high conversion ratio area at the center of the reactor core, and a second burner region formed to the outer circumference thereof and two types of fuels are charged therein. Densified fuel assemblies charged in the high conversion ratio area are separatably formed as fuel assemblies for use in the two types of burners. In this way, dense fuel assembly is separated into two types of fuel assemblies for use in burner of different number and arranging density of fuel elements which can be directly charged to the burner portion and facilitate the dismantling and reassembling of the fuel assemblies. Further, since the two types of fuel assemblies are charged in the burner portion, utilization factor for the neutron fuels can be improved. (Kamimura, M.)

  20. Optical cross-connect circuit using hitless wavelength selective switch.

    Science.gov (United States)

    Goebuchi, Yuta; Hisada, Masahiko; Kato, Tomoyuki; Kokubun, Yasuo

    2008-01-21

    We have proposed and demonstrated the basic elements of a full matrix optical switching circuit (cross-connect circuit) using a hitless wavelength selective switch (WSS). The cross-connect circuits are made of a multi-wavelength channel selective switch consisting of cascaded hitless WSSs, and a multi-port switch. These switching elements are realized through the individual Thermo-Optic (TO) tuning of a series-coupled microring resonator, and can switch arbitrary wavelength channels without blocking other wavelength channels during tuning. We demonstrate a four wavelength selective switch using a parallel topology of double series coupled microring resonators and a three wavelength selective switch using a parallel topology of quadruple series coupled microring resonators. Since the spectrum shape of quadruple series coupled microring is much more box-like than the double series, a high extinction ratio of 39.0-46.6 dB and low switching cross talk of 19.3-24.5 dB were achieved.

  1. Choice of Eye-Safe Radiation Wavelength in UV and Near IR Spectral Bands for Remote Sensing

    Directory of Open Access Journals (Sweden)

    M. L. Belov

    2016-01-01

    Full Text Available The introduction of laser remote sensing systems carries a particular risk to the human’s sense of vision. A structure of the eye, and especially the retina, is the main critical organ as related to the laser radiation.The work uses the optical models of the atmosphere, correctly working in both the UV and the near-IR band, to select the eye-safe radiation wavelengths in the UV (0.355 m and near-IR (~ 1.54 and ~ 2 m spectral bands from the point of view of recorded lidar signal value to fulfill the tasks of laser sensing the natural formations and laser aerosol sensing in the atmosphere.It is shown that the remote sensing lasers with appropriate characteristics can be selected both in the UV band (at a wavelength of 0.355 μm and in the near-IR band (at wavelengths of 1.54 ~ or ~ 2 μm.Molecular scattering has its maximum (for the selected wavelength at a wavelength of 0.355 μm in the UV band, and the minimum at the wavelengths of 1.54 and 2.09 μm in the near -IR band. The main contribution to the molecular absorption at a wavelength of 0.355 μm is made by ozone. In the near-IR spectral band the radiation is absorbed due to water vapor and carbon dioxide.Calculations show that the total effect of the molecular absorption and scattering has no influence on radiation transmission for both the wavelength of 0.355 μm in the UV band, and the wavelengths of 1.54 and 2.09 μm in the near-IR band for sensing trails ~ 1 km.One of the main factors of laser radiation attenuation in the Earth's atmosphere is radiation scattering by aerosol particles.The results of calculations at wavelengths of 0.355 μm, 1.54 μm and 2.09 μm for the several models of the atmosphere show that a choice of the most effective (in terms of the recorded signal of lidar and eye-safe radiation wavelength depends strongly on the task of sensing.To fulfill the task of laser sensing the natural formations, among the eye-safe wavelengths there is one significantly advantageous

  2. Wavelength dependent deformation in a laser peened Ti-2.5Cu alloy

    Energy Technology Data Exchange (ETDEWEB)

    Umapathi, A., E-mail: umapathi.arimakula@gmail.com; Swaroop, S., E-mail: n.r.sathya.swaroop@gmail.com

    2017-01-27

    Laser peening without coating (LPwC) was performed on a Ti-2.5Cu alloy at wavelengths of 1064 and 532 nm and at a constant power density of approximately 7 GW cm{sup −2} with overlap rates of 53%, 63% and 73%. Surface softening due to thermal interaction of laser beam with material was observed till a depth of 500 µm (at 532 nm) and 200 µm (at 1064 nm), based on hardness data. This was corroborated (rather weakly) by residual stress analysis. In addition, softening due to mechanical effects (adiabatic heating) was observed in the bulk. Although there was an increase in mechanical softening with increase in overlap rates at 532 nm, it was observed, upon comparison with peened samples at 1064 nm, that the mechanical softening is a function of wavelength of radiation used for peening. It was observed that the onset of softening was earlier if the wavelength was shorter. Further, evidence of hardening in the form of twinning was found for the 1064 nm case while it was absent for the 532 nm case, for 73% overlap. The workhardened depth was more than 1000 µm, not observed in earlier studies based on residual stress analysis. The direct consequence of softening effect was found in the fatigue results. The fatigue life extended by a factor of 1.4 and 2.3 for the samples peened at 532 nm and 1064 nm respectively, consistent with the observed wavelength dependent onset of softening.

  3. Absorption spectrum of DNA for wavelengths greater than 300 nm

    International Nuclear Information System (INIS)

    Sutherland, J.C.; Griffin, K.P.

    1981-01-01

    Although DNA absorption at wavelengths greater than 300 nm is much weaker than that at shorter wavelengths, this absorption seems to be responsible for much of the biological damage caused by solar radiation of wavelengths less than 320 nm. Accurate measurement of the absorption spectrum of DNA above 300 nm is complicated by turbidity characteristic of concentrated solutions of DNA. We have measured the absorption spectra of DNA from calf thymus, Clostridium perfringens, Escherichia coli, Micrococcus luteus, salmon testis, and human placenta using procedures which separate optical density due to true absorption from that due to turbidity. Above 300 nm, the relative absorption of DNA increases as a function of guanine-cytosine content, presumably because the absorption of guanine is much greater than the absorption of adenine at these wavelengths. This result suggests that the photophysical processes which follow absorption of a long-wavelength photon may, on the average, differ from those induced by shorter-wavelength photons. It may also explain the lower quantum yield for the killing of cells by wavelengths above 300 nm compared to that by shorter wavelengths

  4. Experimental Demonstration of OCDMA Transmission Using a Three-Dimensional (Time-Wavelength-Polarization) Codeset

    Science.gov (United States)

    McGeehan, John E.; Motaghian Nezam, S. M. R.; Saghari, P.; Willner, Alan E.; Omrani, Reza; Vijay Kumar, P.

    2005-10-01

    We experimentally demonstrate a three-dimensional (3-D) optical code-division multiple-access (OCDMA) transmission system that encodes data on time, wavelength, and polarization. Such a system may be ideal for use in short-distance optical local area networks (LANs), where polarization states remain fairly stable. This type of coding can increase the number of potential users, by a factor of approximately 2kappa, over a conventional two-dimensional (2-D) code given the same code constraints, where"kappa"is the number of collisions the codeset will allow. We encode 1-Gbit/s, 11-Gchip/s data with an 11-chip, 4-wavelength, weight-4 (per polarization) code using free-space and fiber delay lines and polarization beam combiners and decode using a polarization beam splitter, wavelength demultiplexers, and additional fiber/free-space delays. After threshold detection using independent detectors for each polarization state, we obtain 1-Gbit/s nonreturn to zero (NRZ) output data. Encoding, transmission decoding, and detection carry a penalty of 1.8 dB.

  5. Influence of production factors on feed intake and feed conversion ratio of grow-finishing pigs

    Directory of Open Access Journals (Sweden)

    Caio Abércio da Silva

    2017-05-01

    Full Text Available The aim of this study was to identify and quantify, through mathematical models, the production factors of grow-finishing (GF phases that influence the daily feed intake (DFI and feed conversion ratio (FCR in pigs. Sixty-five GF farms were evaluated between 2010 and 2013, linked to a cooperative system located in the western Parana State, Brazil, representing 463 batches, with a mean of 642.79 ± 363.29 animals per batch, equalling approximately 300,000 animals. Forty production factors were considered that related to management, sanitation, installations and equipment, nutrition, genetics and environment on the farms. The DFI was influenced by the barn's position relative to the sun (P = 0.048, initial body weight (P < 0.0001 and final body weight (P < 0.0001. It was observed that the FCR was influenced by the barn’s position relative to the sun (P = 0.0001, the use of humidifiers/misting (P = 0.03, the presence of composters (P = 0.006, trees on the sides of barns (P < 0.045, the initial body weight of the pigs (P < 0.0001 and duration of the grow-finishing phase (P < 0.0001. The variables selected in the models explained approximately 44 and 20% of the total variance in the DFI and FCR, respectively, demonstrating that this resource is a good tool for interpreting the factors related to the parameters evaluated.

  6. Sub-wavelength resonances in polygonal metamaterial cylinders

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Breinbjerg, Olav

    2008-01-01

    It has been shown that the sub-wavelength resonances of circular MTM cylinders also occur for polygonal MTM cylinders. This is the case for lossless and non-dispersive cylinders as well as lossy and dispersive cylinders. The sub-wavelength resonances are thus not limited to structures of canonical...

  7. Josephson frequency meter for millimeter and submillimeter wavelengths

    Energy Technology Data Exchange (ETDEWEB)

    Anischenko, S.E.; Larkin, S.Y.; Chaikovsky, V.I. [State Research Center, Kiev (Ukraine)] [and others

    1994-12-31

    Frequency measurements of electromagnetic oscillations of millimeter and submillimeter wavebands with frequency growth due to a number of reasons become more and more difficult. First, these frequencies are considered to be cutoff for semiconductor converting devices and one has to use optical measurement methods instead of traditional ones with frequency transfer. Second, resonance measurement methods are characterized by using relatively narrow bands and optical ones are limited in frequency and time resolution due to the limited range and velocity of movement of their mechanical elements as well as the efficiency of these optical techniques decreases with the increase of wavelength due to diffraction losses. That requires the apriori information on the radiation frequency band of the source involved. Method of measuring frequency of harmonic microwave signals in millimeter and submillimeter wavebands based on the ac Josephson effect in superconducting contacts is devoid of all the above drawbacks. This approach offers a number of major advantages over the more traditional measurement methods, that is the one based on frequency conversion, resonance and interferrometric techniques. It can be characterized by high potential accuracy, wide range of frequencies measured, prompt measurement and the opportunity to obtain panoramic display of the results as well as full automation of the measuring process.

  8. Josephson frequency meter for millimeter and submillimeter wavelengths

    International Nuclear Information System (INIS)

    Anischenko, S.E.; Larkin, S.Y.; Chaikovsky, V.I.

    1994-01-01

    Frequency measurements of electromagnetic oscillations of millimeter and submillimeter wavebands with frequency growth due to a number of reasons become more and more difficult. First, these frequencies are considered to be cutoff for semiconductor converting devices and one has to use optical measurement methods instead of traditional ones with frequency transfer. Second, resonance measurement methods are characterized by using relatively narrow bands and optical ones are limited in frequency and time resolution due to the limited range and velocity of movement of their mechanical elements as well as the efficiency of these optical techniques decreases with the increase of wavelength due to diffraction losses. That requires the apriori information on the radiation frequency band of the source involved. Method of measuring frequency of harmonic microwave signals in millimeter and submillimeter wavebands based on the ac Josephson effect in superconducting contacts is devoid of all the above drawbacks. This approach offers a number of major advantages over the more traditional measurement methods, that is the one based on frequency conversion, resonance and interferrometric techniques. It can be characterized by high potential accuracy, wide range of frequencies measured, prompt measurement and the opportunity to obtain panoramic display of the results as well as full automation of the measuring process

  9. Sample Dilution and Bacterial Community Composition Influence Empirical Leucine-to-Carbon Conversion Factors in Surface Waters of the World's Oceans

    KAUST Repository

    Teira, Eva; Hernando-Morales, Ví ctor; Cornejo-Castillo, Francisco M.; Alonso-Sá ez, Laura; Sarmento, Hugo; Valencia-Vila, Joaquí n; Serrano Catalá , Teresa; Herná ndez-Ruiz, Marta; Varela, Marta M.; Ferrera, Isabel; Moran, Xose Anxelu G.; Gasol, Josep M.

    2015-01-01

    The transformation of leucine incorporation rates to prokaryotic carbon production rates requires the use of either theoretical or empirically determined conversion factors. Empirical leucine-to-carbon conversion factors (eCFs) vary widely across environments, and little is known about their potential controlling factors. We conducted 10 surface seawater manipulation experiments across the world's oceans, where the growth of the natural prokaryotic assemblages was promoted by filtration (i.e., removal of grazers [F treatment]) or filtration combined with dilution (i.e., also relieving resource competition [FD treatment]). The impact of sunlight exposure was also evaluated in the FD treatments, and we did not find a significant effect on the eCFs. The eCFs varied from 0.09 to 1.47 kg C mol Leu−1 and were significantly lower in the FD than in the F samples. Also, changes in bacterial community composition during the incubations, as assessed by automated ribosomal intergenic spacer analysis (ARISA), were more pronounced in the FD than in the F treatments, compared to unmanipulated controls. Thus, we discourage the common procedure of diluting samples (in addition to filtration) for eCF determination. The eCFs in the filtered treatment were negatively correlated with the initial chlorophyll a concentration, picocyanobacterial abundance (mostly Prochlorococcus), and the percentage of heterotrophic prokaryotes with high nucleic acid content (%HNA). The latter two variables explained 80% of the eCF variability in the F treatment, supporting the view that both Prochlorococcus and HNA prokaryotes incorporate leucine in substantial amounts, although this results in relatively low carbon production rates in the oligotrophic ocean.

  10. Sample Dilution and Bacterial Community Composition Influence Empirical Leucine-to-Carbon Conversion Factors in Surface Waters of the World's Oceans

    KAUST Repository

    Teira, Eva

    2015-09-25

    The transformation of leucine incorporation rates to prokaryotic carbon production rates requires the use of either theoretical or empirically determined conversion factors. Empirical leucine-to-carbon conversion factors (eCFs) vary widely across environments, and little is known about their potential controlling factors. We conducted 10 surface seawater manipulation experiments across the world\\'s oceans, where the growth of the natural prokaryotic assemblages was promoted by filtration (i.e., removal of grazers [F treatment]) or filtration combined with dilution (i.e., also relieving resource competition [FD treatment]). The impact of sunlight exposure was also evaluated in the FD treatments, and we did not find a significant effect on the eCFs. The eCFs varied from 0.09 to 1.47 kg C mol Leu−1 and were significantly lower in the FD than in the F samples. Also, changes in bacterial community composition during the incubations, as assessed by automated ribosomal intergenic spacer analysis (ARISA), were more pronounced in the FD than in the F treatments, compared to unmanipulated controls. Thus, we discourage the common procedure of diluting samples (in addition to filtration) for eCF determination. The eCFs in the filtered treatment were negatively correlated with the initial chlorophyll a concentration, picocyanobacterial abundance (mostly Prochlorococcus), and the percentage of heterotrophic prokaryotes with high nucleic acid content (%HNA). The latter two variables explained 80% of the eCF variability in the F treatment, supporting the view that both Prochlorococcus and HNA prokaryotes incorporate leucine in substantial amounts, although this results in relatively low carbon production rates in the oligotrophic ocean.

  11. The Role of Conversation Policy in Carrying Out Agent Conversations

    International Nuclear Information System (INIS)

    Link, Hamilton E.; Phillips, Laurence R.

    1999-01-01

    Structured conversation diagrams, or conversation specifications, allow agents to have predictable interactions and achieve predefined information-based goals, but they lack the flexibility needed to function robustly in an unpredictable environment. We propose a mechanism that combines a typical conversation structure with a separately established policy to generate an actual conversation. The word ''policy'' connotes a high-level direction external to a specific planned interaction with the environment. Policies, which describe acceptable procedures and influence decisions, can be applied to broad sets of activity. Based on their observation of issues related to a policy, agents may dynamically adjust their communication patterns. The policy object describes limitations, constraints, and requirements that may affect the conversation in certain circumstances. Using this new mechanism of interaction simplifies the description of individual conversations and allows domain-specific issues to be brought to bear more easily during agent communication. By following the behavior of the conversation specification when possible and deferring to the policy to derive behavior in exceptional circumstances, an agent is able to function predictably under normal situations and still act rationally in abnormal situations. Different conversation policies applied to a given conversation specification can change the nature of the interaction without changing the specification

  12. Engineering quadratic nonlinear photonic crystals for frequency conversion of lasers

    Science.gov (United States)

    Chen, Baoqin; Hong, Lihong; Hu, Chenyang; Zhang, Chao; Liu, Rongjuan; Li, Zhiyuan

    2018-03-01

    Nonlinear frequency conversion offers an effective way to extend the laser wavelength range. Quadratic nonlinear photonic crystals (NPCs) are artificial materials composed of domain-inversion structures whose sign of nonlinear coefficients are modulated with desire to implement quasi-phase matching (QPM) required for nonlinear frequency conversion. These structures can offer various reciprocal lattice vectors (RLVs) to compensate the phase-mismatching during the quadratic nonlinear optical processes, including second-harmonic generation (SHG), sum-frequency generation and the cascaded third-harmonic generation (THG). The modulation pattern of the nonlinear coefficients is flexible, which can be one-dimensional or two-dimensional (2D), be periodic, quasi-periodic, aperiodic, chirped, or super-periodic. As a result, these NPCs offer very flexible QPM scheme to satisfy various nonlinear optics and laser frequency conversion problems via design of the modulation patterns and RLV spectra. In particular, we introduce the electric poling technique for fabricating QPM structures, a simple effective nonlinear coefficient model for efficiently and precisely evaluating the performance of QPM structures, the concept of super-QPM and super-periodically poled lithium niobate for finely tuning nonlinear optical interactions, the design of 2D ellipse QPM NPC structures enabling continuous tunability of SHG in a broad bandwidth by simply changing the transport direction of pump light, and chirped QPM structures that exhibit broadband RLVs and allow for simultaneous radiation of broadband SHG, THG, HHG and thus coherent white laser from a single crystal. All these technical, theoretical, and physical studies on QPM NPCs can help to gain a deeper insight on the mechanisms, approaches, and routes for flexibly controlling the interaction of lasers with various QPM NPCs for high-efficiency frequency conversion and creation of novel lasers.

  13. Synaptic Conversion of Chloride-Dependent Synapses in Spinal Nociceptive Circuits: Roles in Neuropathic Pain

    Directory of Open Access Journals (Sweden)

    Mark S. Cooper

    2011-01-01

    Full Text Available Electrophysiological conversion of chloride-dependent synapses from inhibitory to excitatory function, as a result of aberrant neuronal chloride homeostasis, is a known mechanism for the genesis of neuropathic pain. This paper examines theoretically how this type of synaptic conversion can disrupt circuit logic in spinal nociceptive circuits. First, a mathematical scaling factor is developed to represent local aberration in chloride electrochemical driving potential. Using this mathematical scaling factor, electrophysiological symbols are developed to represent the magnitude of synaptic conversion within nociceptive circuits. When inserted into a nociceptive circuit diagram, these symbols assist in understanding the generation of neuropathic pain associated with the collapse of transmembrane chloride gradients. A more generalized scaling factor is also derived to represent the interplay of chloride and bicarbonate driving potentials on the function of GABAergic and glycinergic synapses. These mathematical and symbolic representations of synaptic conversion help illustrate the critical role that anion driving potentials play in the transduction of pain. Using these representations, we discuss ramifications of glial-mediated synaptic conversion in the genesis, and treatment, of neuropathic pain.

  14. Sputum Conversion Among Patients With Smear Positive Pulmonary Tuberculosis

    Directory of Open Access Journals (Sweden)

    Soudbakhsh A R

    2003-06-01

    Full Text Available Introduction: In the patients with smear-positive pulmonary tuberculosis (TB bacteriologic assessment of sputum for detection of acid bacilli (AFB Has essential role. This evaluation is accomplished by direct sputum smear & sputum culture. These examinations must be done in regular and preferably monthly after beginning of treatment. These tests have two important aims, including, determining of treatment efficacy & duration of isolation."nMethods and Materials: Most of the studies have that classic six month regimen led to sputum smear conversion & negative sputum culture in 85% of patient. This treatment regimen has two phases, including, attack phase and maintenance phase. In the attack phase we use four drugs, including, Isoniazid (INH, Rifampin (RMP, Pyrazinamide (PZA and Ethambutol (EMB for the first 2 months and if necessary until the end of third month. In the maintenance phase we use INH and Rif for the remaining of treatment course. The main objectives of this study were to determine the time needed for smear conversion and assessment of probable factors which may influence the smear conversion until 4 months after beginning of therapy. The factors that were assessed, were, Age, nationality, sex, clinical symptoms, underlying diseases, chest radiography (number of cavities, smoking, drug abuse and concentration of AF13 in the sputum Generally, we did this cross sectional study on the patient's records, who had been observed in Imam Khomeni Hospital, west health service center and masih daneshvary hospital between."nResults: This study showed that from totally 218 patients, 138(74.6% patients had sputum conversion at the first 2 months of treatment and until the end of 3rd & 4th month this rate reached to 83.3% respectively. So in the end of fourth month only 32(14.7% patients did not show sputum smear conversion. On the other hand this study showed that two factors including presence of cavities in chest radiography

  15. Conversion total hip arthroplasty: Primary or revision total hip arthroplasty

    Science.gov (United States)

    Schwarzkopf, Ran; Baghoolizadeh, Mahta

    2015-01-01

    Total hip arthroplasty (THA) is an increasingly common procedure among elderly individuals. Although conversion THA is currently bundled in a diagnosis related group (DRG) with primary THA, there is a lack of literature supporting this classification and it has yet to be identified whether conversion THA better resembles primary or revision THA. This editorial analyzed the intraoperative and postoperative factors and functional outcomes following conversion THA, primary THA, and revision THA to understand whether the characteristics of conversion THA resemble one procedure or the other, or are possibly somewhere in between. The analysis revealed that conversion THA requires more resources both intraoperatively and postoperatively than primary THA. Furthermore, patients undergoing conversion THA present with poorer functional outcomes in the long run. Patients undergoing conversion THA better resemble revision THA patients than primary THA patients. As such, patients undergoing conversion THA should not be likened to patients undergoing primary THA when determining risk stratification and reimbursement rates. Conversion THA procedures should be planned accordingly with proper anticipation of the greater needs both in the operating room, and for in-patient and follow-up care. We suggest that conversion THA be reclassified in the same DRG with revision THA as opposed to primary THA as a step towards better allocation of healthcare resources for conversion hip arthroplasties. PMID:26601055

  16. Multi-wavelength Characterization of Brown and Black Carbon from Filter Samples

    Science.gov (United States)

    Johnson, M. M.; Yatavelli, R. L. N.; Chen, L. W. A. A.; Gyawali, M. S.; Arnott, W. P.; Wang, X.; Chakrabarty, R. K.; Moosmüller, H.; Watson, J. G.; Chow, J. C.

    2014-12-01

    Particulate matter (PM) scatters and absorbs solar radiation and thereby affects visibility, the Earth's radiation balance, and properties and lifetimes of clouds. Understanding the radiative forcing (RF) of PM is essential to reducing the uncertainty in total anthropogenic and natural RF. Many instruments that measure light absorption coefficients (βabs [λ], Mm-1) of PM have used light at near-infrared (NIR; e.g., 880 nm) or red (e.g., 633 nm) wavelengths. Measuring βabs over a wider wavelength range, especially including the ultraviolet (UV) and visible, allows for contributions from black carbon (BC), brown carbon (BrC), and mineral dust (MD) to be differentiated. This will help to determine PM RF and its emission sources. In this study, source and ambient samples collected on Teflon-membrane and quartz-fiber filters are used to characterize and develop a multi-wavelength (250 - 1000 nm) filter-based measurement method of PM light absorption. A commercially available UV-visible spectrometer coupled with an integrating sphere is used for quantifying diffuse reflectance and transmittance of filter samples, from which βabs and absorption Ǻngström exponents (AAE) of the PM deposits are determined. The filter-based light absorption measurements of laboratory generated soot and biomass burning aerosol are compared to 3-wavelength photoacoustic absorption measurements to evaluate filter media and loading effects. Calibration factors are developed to account for differences between filter types (Teflon-membrane vs. quartz-fiber), and between filters and in situ photoacoustic absorption values. Application of multi-spectral absorption measurements to existing archived filters, including specific source samples (e.g. diesel and gasoline engines, biomass burning, dust), will also be discussed.

  17. Wavelength stabilized high pulse power laser diodes for automotive LiDAR

    Science.gov (United States)

    Knigge, A.; Klehr, A.; Wenzel, H.; Zeghuzi, A.; Fricke, J.; Maaßdorf, A.; Liero, A.; Tränkle, G.

    2018-03-01

    Diode lasers generating optical pulses with high peak power and lengths in the nanosecond range are key components of systems for free-space communication, metrology, material processing, spectroscopy, and light detection and ranging (LiDAR) as needed for object detection and autonomous driving. Automotive LiDAR systems demand additionally a good beam quality and low wavelength shift with temperature due to the wide operating temperature span. We present here internally wavelength stabilized lasers emitting ns optical pulses from an emission aperture between 30 μm and 100 μm with peak powers of tens of Watts at wavelengths around 905 nm. The vertical structure based on AlGaAs (confinement and cladding layers) and InGaAs (active quantum well) is especially optimized for pulsed operation with respect to the implementation of a surface Bragg grating with a high reflectivity. The fabricated 6 mm long distributed Bragg reflector (DBR) broad area (BA) lasers are electrically driven by an in-house developed high-speed unit generating 3 to 10 ns long nearly rectangular shaped current pulses with amplitudes of up to 250 A. Such lasers emit optical pulses with a peak power of more than 30 W at 95 A pulse current up to a temperature of 85°C with a wavelength shift as low as 65 pm/K and a lateral beam propagation factor less than 10. The influence of the lateral aperture width and the pulse length on the beam quality will be shown. A monolithic integration of 3 DBR BA lasers on a single chip whose emission can be combined into a single beam raises the output power to more than 100 W.

  18. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    CERN Document Server

    Sakamoto, Y; Sato, O; Tanaka, S I; Tsuda, S; Yamaguchi, Y; Yoshizawa, N

    2003-01-01

    In the International Commission on Radiological Protection (ICRP) 1990 Recommendations, radiation weighting factors were introduced in the place of quality factors, the tissue weighting factors were revised, and effective doses and equivalent doses of each tissues and organs were defined as the protection quantities. Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of theses data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality fact...

  19. Prosopagnosia as a Type of Conversion Disorder.

    Science.gov (United States)

    Power, Clodagh; Hannigan, Oisin; Coen, Robert; Bruce, Irene; Gibb, Matthew; McCarthy, Marie; Robinson, David; Lawlor, Brian A

    2018-01-01

    Conversion disorder is a common and debilitating condition that remains poorly understood. We present a previously undescribed form of conversion disorder to highlight the complexity of the condition and consider the interplay of factors that produce conversion symptoms. A 50-year-old male presented with acquired prosopagnosia and language impairment. Neuropsychological testing indicated right temporal lobe dysfunction. Extensive work-up outruled an organic aetiology. Reactivation of childhood trauma coincided with the onset of his symptoms. Childhood trauma is known to have adverse effects on the developing brain which may affect an individual's emotional behaviour and coping style. Functional neuroimaging techniques suggest that conversion symptoms may be linked to the disruption of higher order neural circuitry involved in the integration of emotional processing and cortical functioning. We propose that our patient's adverse childhood experiences led to the development of a particular personality and coping style that "primed" him for a later abnormal emotional and behavioural response when confronted with reminders of his traumatic background. Further interdisciplinary studies are required to further elucidate the neurobiological basis for this condition.

  20. Dose conversion coefficients for high-energy photons, electrons, neutrons and protons

    International Nuclear Information System (INIS)

    Sakamoto, Yukio

    2005-01-01

    Dose conversion coefficients for photons, electrons and neutrons based on new ICRP recommendations were cited in the ICRP Publication 74, but the energy ranges of these data were limited and there are no data for high energy radiations produced in accelerator facilities. For the purpose of designing the high intensity proton accelerator facilities at JAERI, the dose evaluation code system of high energy radiations based on the HERMES code was developed and the dose conversion coefficients of effective dose were evaluated for photons, neutrons and protons up to 10 GeV, and electrons up to 100 GeV. The dose conversion coefficients of effective dose equivalent were also evaluated using quality factors to consider the consistency between radiation weighting factors and Q-L relationship. The effective dose conversion coefficients obtained in this work were in good agreement with those recently evaluated by using FLUKA code for photons and electrons with all energies, and neutrons and protons below 500 MeV. There were some discrepancy between two data owing to the difference of cross sections in the nuclear reaction models. The dose conversion coefficients of effective dose equivalents for high energy radiations based on Q-L relation in ICRP Publication 60 were evaluated only in this work. The previous comparison between effective dose and effective dose equivalent made it clear that the radiation weighting factors for high energy neutrons and protons were overestimated and the modification was required. (author)

  1. Kinetics of Scheelite Conversion in Sulfuric Acid

    Science.gov (United States)

    Shen, Leiting; Li, Xiaobin; Zhou, Qiusheng; Peng, Zhihong; Liu, Guihua; Qi, Tiangui; Taskinen, Pekka

    2018-02-01

    Complete conversion of scheelite in H2SO4 solution plays a key role in exploration of cleaner technology for producing ammonium paratungstate. In this work, the factors influencing scheelite conversion were investigated experimentally to model its kinetics. The results indicated that the conversion rate increases with increasing temperature and reducing particle size, but is almost independent of stirring speed. Moreover, although the conversion rate increases with increasing initial H2SO4 concentration (≤ 1.25 mol/L), it decreases rapidly at 1.5 mol/L H2SO4 after 10 min due to formation of a H2WO4 layer. The experimental data agree quite well with the shrinking core model under chemical reaction control in ≤ 1.25 mol/L H2SO4 solution, and the kinetic equation was established as: 1- ( 1- α )^{ 1 / 3} = 2 2 2 5 4 6. 6\\cdot C_{{{H}_{ 2} {SO}_{ 4} }}^{ 1. 2 2 6} \\cdot r_{ 0}^{ - 1} \\cdot e^{{ - 3 9 2 6 0/RT}} \\cdot t (t, min). This work could contribute to better understanding of scheelite conversion in H2SO4 solution and development of a new route for ammonium paratungstate production.

  2. MHz rate and efficient synchronous heralding of single photons at telecom wavelengths.

    Science.gov (United States)

    Pomarico, Enrico; Sanguinetti, Bruno; Guerreiro, Thiago; Thew, Rob; Zbinden, Hugo

    2012-10-08

    We report on the realization of a synchronous source of heralded single photons at telecom wavelengths with MHz heralding rates and high heralding efficiency. This source is based on the generation of photon pairs at 810 and 1550 nm via Spontaneous Parametric Down Conversion (SPDC) in a 1 cm periodically poled lithium niobate (PPLN) crystal pumped by a 532 nm pulsed laser. As high rates are fundamental for multi-photon experiments, we show that single telecom photons can be announced at 4.4 MHz rate with 45% heralding efficiency. When we focus only on the optimization of the coupling of the heralded photon, the heralding efficiency can be increased up to 80%. Furthermore, we experimentally observe that group velocity mismatch inside long crystals pumped in a pulsed mode affects the spectrum of the emitted photons and their fibre coupling efficiency. The length of the crystal in this source has been chosen as a trade off between high brightness and high coupling efficiency.

  3. Penetration effect in internal conversion and nuclear structure

    International Nuclear Information System (INIS)

    Listengarten, M.A.

    1978-01-01

    The conditions for the appearance of the anomalous internal conversion coefficients (ICC) are considered, when the contribution of the penetration matrix element (PME) is of the order of or larger than the main part of the conversion matrix element. The experimental magnitudes of the nuclear PME agree well with those calculated in the framework of simple nuclear models, provided the magnitude of PME is not decreased due to the model -dependent selection rules. The magnitude of the anomaly ( lanbda parameter ) is compared with the exclusion factor of γ-transition relative to the Weisskopf estimation. The better is the model of the nucleus the weaker is the dependence of the lambda magnitude on the exclusion factor. ICC coefficients might be anomalous for those γ-transitions for which the exclusion factor calculated in the framework of more rigorous model are of the order of unity. In the ''ideal'' model of nucleus completely adequate to the true nuclear structure the dependence of the lambda penetration parameter on the exclusion factor vanishes

  4. Full 3D modelling of pulse propagation enables efficient nonlinear frequency conversion with low energy laser pulses in a single-element tripler

    Science.gov (United States)

    Kardaś, Tomasz M.; Nejbauer, Michał; Wnuk, Paweł; Resan, Bojan; Radzewicz, Czesław; Wasylczyk, Piotr

    2017-02-01

    Although new optical materials continue to open up access to more and more wavelength bands where femtosecond laser pulses can be generated, light frequency conversion techniques are still indispensable in filling the gaps on the ultrafast spectral scale. With high repetition rate, low pulse energy laser sources (oscillators) tight focusing is necessary for a robust wave mixing and the efficiency of broadband nonlinear conversion is limited by diffraction as well as spatial and temporal walk-off. Here we demonstrate a miniature third harmonic generator (tripler) with conversion efficiency exceeding 30%, producing 246 fs UV pulses via cascaded second order processes within a single laser beam focus. Designing this highly efficient and ultra compact frequency converter was made possible by full 3-dimentional modelling of propagation of tightly focused, broadband light fields in nonlinear and birefringent media.

  5. A simple method for conversion of airborne gamma-ray spectra to ground level doses

    DEFF Research Database (Denmark)

    Korsbech, Uffe C C; Bargholz, Kim

    1996-01-01

    A new and simple method for conversion of airborne NaI(Tl) gamma-ray spectra to dose rates at ground level has been developed. By weighting the channel count rates with the channel numbers a spectrum dose index (SDI) is calculated for each spectrum. Ground level dose rates then are determined...... by multiplying the SDI by an altitude dependent conversion factor. The conversion factors are determined from spectra based on Monte Carlo calculations. The results are compared with measurements in a laboratory calibration set-up. IT-NT-27. June 1996. 27 p....

  6. Modeling Urban Expansion and Agricultural Land Conversion in Henan Province, China: An Integration of Land Use and Socioeconomic Data

    Directory of Open Access Journals (Sweden)

    Li Jiang

    2016-09-01

    Full Text Available China has experienced rapid urban expansion and agricultural land loss, and the land conversion has accelerated in central provinces since the mid-1990s. The goal of this paper is to examine the relative importance of socioeconomic and policy factors on the urban conversion of agricultural land in Henan Province, China. Using panel econometric models, we examine how socioeconomic and policy factors affect agricultural land conversion at the county level across three time periods, 1995–2000, 2000–2005, and 2005–2010. The results show that both urban land rent and urban wages are essential factors that positively contribute to the conversion of agricultural land. It is also found that per capita GDP is correlated with more urban development and agricultural land loss. Consistent with expectations, agricultural financial support is negatively correlated with agricultural land conversion, suggesting a policy success. Finally, the decomposition analysis illustrates that urban wages are the most influential positive factor and agricultural financial support is the most influential negative factor affecting the urban conversion of agricultural land.

  7. Improvement of skeleton conversion in ICRP reference phantom conversion project

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Zhao Jun; Yeom, Yeon Soo; Thang, Nguyen Tat; Kim, Han Sung; Han, Min Cheol; Kim, Chan Hyeong [Dept. of Nuclear Engineering, Hanyang University, Seoul (Korea, Republic of); Kim, Seong Hoon [Dept. of Radiation Oncology, College of Medicine, Hanyang University, Seoul (Korea, Republic of)

    2014-11-15

    In the previous skeleton conversion, most bones were directly converted from the ICRP voxel phantoms by using the 3D rendering method whereas several complex-shape bones (cranium, ribs, spines, feet, and hands) were not able to be directly converted. We alternatively employed the corresponding well-defined polygonal models and attempted to adjust them to match the voxel models. However, this approach was unsatisfactory. The shapes of the alternative models were significantly different from those of the voxel models, making it virtually impossible to exactly match the voxel models as shown in Fig. 3 (left). In order to overcome the difficulty in the complex bone conversion, the present study developed a new conversion method and converted these complex bones voxel models of the ICRP male phantom to polygonal models. The present study developed the new conversion method and successfully improved polygonal models for cranium, ribs, and spines for the ICRP male phantom. The new conversion method will be also applied to the complex bone conversion for the ICRP female phantom as well as other complex organ conversion in the future.

  8. Improvement of skeleton conversion in ICRP reference phantom conversion project

    International Nuclear Information System (INIS)

    Wang, Zhao Jun; Yeom, Yeon Soo; Thang, Nguyen Tat; Kim, Han Sung; Han, Min Cheol; Kim, Chan Hyeong; Kim, Seong Hoon

    2014-01-01

    In the previous skeleton conversion, most bones were directly converted from the ICRP voxel phantoms by using the 3D rendering method whereas several complex-shape bones (cranium, ribs, spines, feet, and hands) were not able to be directly converted. We alternatively employed the corresponding well-defined polygonal models and attempted to adjust them to match the voxel models. However, this approach was unsatisfactory. The shapes of the alternative models were significantly different from those of the voxel models, making it virtually impossible to exactly match the voxel models as shown in Fig. 3 (left). In order to overcome the difficulty in the complex bone conversion, the present study developed a new conversion method and converted these complex bones voxel models of the ICRP male phantom to polygonal models. The present study developed the new conversion method and successfully improved polygonal models for cranium, ribs, and spines for the ICRP male phantom. The new conversion method will be also applied to the complex bone conversion for the ICRP female phantom as well as other complex organ conversion in the future

  9. Derivation of ingestion dose conversion factors for the U-238 decay series

    International Nuclear Information System (INIS)

    Jenkins, P.H.; Nicoll, R.M.; Doty, R.L.

    1978-01-01

    Dose conversion factors (DCF's) for the U-238 decay series were derived for use in the assessment of potential doses to man, through several ingestion pathways, by radionuclide deposition from radioactive airborne effluents. The methodology used, although similar to that outlined in the U.S. Nuclear Regulatory Commission's Regulatory Guide 1.109, is complicated by consideration of the ingrowth of decay products. Eight ingestion pathways were considered: (1) fresh vegetables, (2) stored vegetables, (3) milk from cows that eat pasture grass, (4) milk from cows that eat stored feed, (5) goat milk - pasture grass, (6) goat milk - stored feed, (7) beef - pasture grass, and (8) beef - stored feed. Radionuclide deposition was assumed to occur for the entire operational lifetime of the facility. Because the expected operational lifetime may vary from facility to facility, DCF's were calculated for six lifetimes: 10, 15, 20, 25, 30, and 35 years. DCF's were calculated for each of 13 'parent' nuclides in the decay series, with each DCF considering the ingrowth of all subsequent nuclides in the series. The methodology used to derive the DCF's is detailed, and DCF's normalized to a deposition rate of the parent nuclide of 1 μCi m -2 s -1 are reported. (author)

  10. Emission wavelength of multilayer distributed feedback dye lasers

    DEFF Research Database (Denmark)

    Vannahme, Christoph; Smith, Cameron L. C.; Brøkner Christiansen, Mads

    2012-01-01

    Precise emission wavelength modeling is essential for understanding and optimization of distributed feedback (DFB) lasers. An analytical approach for determining the emission wavelength based on setting the propagation constant of the Bragg condition and solving for the resulting slab waveguide m...

  11. Wavelength encoding technique for particle analyses in hematology analyzer

    Science.gov (United States)

    Rongeat, Nelly; Brunel, Patrick; Gineys, Jean-Philippe; Cremien, Didier; Couderc, Vincent; Nérin, Philippe

    2011-07-01

    The aim of this study is to combine multiple excitation wavelengths in order to improve accuracy of fluorescence characterization of labeled cells. The experimental demonstration is realized with a hematology analyzer based on flow cytometry and a CW laser source emitting two visible wavelengths. A given optical encoding associated to each wavelength allows fluorescence identification coming from specific fluorochromes and avoiding the use of noisy compensation method.

  12. Sample dilution and bacterial community composition influence empirical leucine-to-carbon conversion factors in surface waters of the world's oceans.

    Science.gov (United States)

    Teira, Eva; Hernando-Morales, Víctor; Cornejo-Castillo, Francisco M; Alonso-Sáez, Laura; Sarmento, Hugo; Valencia-Vila, Joaquín; Serrano Catalá, Teresa; Hernández-Ruiz, Marta; Varela, Marta M; Ferrera, Isabel; Gutiérrez Morán, Xosé Anxelu; Gasol, Josep M

    2015-12-01

    The transformation of leucine incorporation rates to prokaryotic carbon production rates requires the use of either theoretical or empirically determined conversion factors. Empirical leucine-to-carbon conversion factors (eCFs) vary widely across environments, and little is known about their potential controlling factors. We conducted 10 surface seawater manipulation experiments across the world's oceans, where the growth of the natural prokaryotic assemblages was promoted by filtration (i.e., removal of grazers [F treatment]) or filtration combined with dilution (i.e., also relieving resource competition [FD treatment]). The impact of sunlight exposure was also evaluated in the FD treatments, and we did not find a significant effect on the eCFs. The eCFs varied from 0.09 to 1.47 kg C mol Leu(-1) and were significantly lower in the FD than in the F samples. Also, changes in bacterial community composition during the incubations, as assessed by automated ribosomal intergenic spacer analysis (ARISA), were more pronounced in the FD than in the F treatments, compared to unmanipulated controls. Thus, we discourage the common procedure of diluting samples (in addition to filtration) for eCF determination. The eCFs in the filtered treatment were negatively correlated with the initial chlorophyll a concentration, picocyanobacterial abundance (mostly Prochlorococcus), and the percentage of heterotrophic prokaryotes with high nucleic acid content (%HNA). The latter two variables explained 80% of the eCF variability in the F treatment, supporting the view that both Prochlorococcus and HNA prokaryotes incorporate leucine in substantial amounts, although this results in relatively low carbon production rates in the oligotrophic ocean. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  13. 5.5nm wavelength-tunable high-power MOPA diode laser system at 971 nm

    Science.gov (United States)

    Tawfieq, Mahmoud; Müller, André; Fricke, Jörg; Della Casa, Pietro; Ressel, Peter; Ginolas, Arnim; Feise, David; Sumpf, Bernd; Tränkle, Günther

    2018-02-01

    In this work, a widely tunable hybrid master oscillator power amplifier (MOPA) diode laser with 6.2 W of output power at 971.8 nm will be presented. The MO is a DBR laser, with a micro heater embedded on top of the DBR grating for wavelength tunability. The emitted light of the MO is collimated and coupled into a tapered amplifier using micro cylindrical lenses, all constructed on a compact 25 mm × 25 mm conduction cooled laser package. The MOPA system emits light with a measured spectral width smaller than 17 pm, limited by the spectrometer, and with a beam propagation factor of M2 1/e2 = 1.3 in the slow axis. The emission is thus nearly diffraction limited with 79% of the total power within the central lobe (4.9 W diffraction limited). The electrically controlled micro-heater provides up to 5.5 nm of wavelength tunability, up to a wavelength of 977.3 nm, while maintaining an output power variation of only +/- 0.16 % for the entire tuning range.

  14. Discourse analysis: Conversational analysis of the internal conversation in Oracle Corporation Malaysia

    Directory of Open Access Journals (Sweden)

    Marwa Marwa

    2017-07-01

    Full Text Available This study highlights the internal conversation which takes place in Oracle CorporationMalaysia. Through the study, it will be shown how conversational analysis is used toanalyze the transcription of a telephone conversation between Oracle staffs. The analysisof the transcriptions will apply a few basic concepts of conversational analysis; turntakingorganization, and the adjacency pair. The objective of the study is to find out howthe internal conversations takes place by focusing on the conversation itself, that is, theconversational structures spontaneously produced by people during talk ranging fromturn-taking strategies, how topics are introduced, conversation closings and so on. Bylooking in detail at such talk, we can gain a detailed understanding of how the staffs seethemselves in relation to the company that influence their daily lives.Keywords: conversational analysis, turn-taking, adjacency pairs

  15. MoS2-wrapped microfiber-based multi-wavelength soliton fiber laser

    Science.gov (United States)

    Lu, Feifei

    2017-11-01

    The single-, dual- and triple-wavelength passively mode-locked erbium-doped fiber lasers are demonstrated with MoS2 and polarization-dependent isolator (PD-ISO). The saturable absorber is fabricated by wrapping an MoS2 around a microfiber. The intracavity PD-ISO acts as a wavelength-tunable filter with a polarization controller (PC) by adjusting the linear birefringence. Single-wavelength mode-locked fiber laser can self-start with suitable pump power. With appropriate PC state, dual- and triple-wavelength operations can be observed when gains at different wavelengths reach a balance. It is noteworthy that dual-wavelength pulses exhibiting peak and dip sidebands, respectively, are demonstrated in the experiment. The proposed simple and multi-wavelength all-fiber conventional soliton lasers could possess potential applications in numerous fields, such as sensors, THz generations and optical communications.

  16. Wavelength Selection Method Based on Differential Evolution for Precise Quantitative Analysis Using Terahertz Time-Domain Spectroscopy.

    Science.gov (United States)

    Li, Zhi; Chen, Weidong; Lian, Feiyu; Ge, Hongyi; Guan, Aihong

    2017-12-01

    Quantitative analysis of component mixtures is an important application of terahertz time-domain spectroscopy (THz-TDS) and has attracted broad interest in recent research. Although the accuracy of quantitative analysis using THz-TDS is affected by a host of factors, wavelength selection from the sample's THz absorption spectrum is the most crucial component. The raw spectrum consists of signals from the sample and scattering and other random disturbances that can critically influence the quantitative accuracy. For precise quantitative analysis using THz-TDS, the signal from the sample needs to be retained while the scattering and other noise sources are eliminated. In this paper, a novel wavelength selection method based on differential evolution (DE) is investigated. By performing quantitative experiments on a series of binary amino acid mixtures using THz-TDS, we demonstrate the efficacy of the DE-based wavelength selection method, which yields an error rate below 5%.

  17. Thick sputtered tantalum coatings for high-temperature energy conversion applications

    Energy Technology Data Exchange (ETDEWEB)

    Stelmakh, Veronika, E-mail: stelmakh@mit.edu; Peykov, Daniel; Chan, Walker R.; Senkevich, Jay J.; Joannopoulos, John D.; Soljačić, Marin; Celanovic, Ivan [Institute for Soldier Nanotechnologies, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Castillo, Robert; Coulter, Kent; Wei, Ronghua [Materials Engineering Department, Southwest Research Institute, San Antonio, Texas 78238 (United States)

    2015-11-15

    Thick sputtered tantalum (Ta) coatings on polished Inconel were investigated as a potential replacement for bulk refractory metal substrates used for high-temperature emitters and absorbers in thermophotovoltaic energy conversion applications. In these applications, high-temperature stability and high reflectance of the surface in the infrared wavelength range are critical in order to sustain operational temperatures and reduce losses due to waste heat. The reflectance of the coatings (8 and 30 μm) was characterized with a conformal protective hafnia layer as-deposited and after one hour anneals at 700, 900, and 1100 °C. To further understand the high-temperature performance of the coatings, the microstructural evolution was investigated as a function of annealing temperature. X-ray diffraction was used to analyze the texture and residual stress in the coatings at four reflections (220, 310, 222, and 321), as-deposited and after anneal. No significant changes in roughness, reflectance, or stress were observed. No delamination or cracking occurred, even after annealing the coatings at 1100 °C. Overall, the results of this study suggest that the thick Ta coatings are a promising alternative to bulk substrates and pave the way for a relatively low-cost and easily integrated platform for nanostructured devices in high-temperature energy conversion applications.

  18. Radiative flux calculations at UV and visible wavelengths

    International Nuclear Information System (INIS)

    Grossman, A.S.; Grant, K.E.; Wuebbles, D.J.

    1993-10-01

    A radiative transfer model to calculate the short wavelength fluxes at altitudes between 0 and 80 km has been developed at LLNL. The wavelength range extends from 175--735 nm. This spectral range covers the UV-B wavelength region, 250--350 nm, with sufficient resolution to allow comparison of UV-B measurements with theoretical predictions. Validation studies for the model have been made for both UV-B ground radiation calculations and tropospheric solar radiative forcing calculations for various ozone distributions. These studies indicate that the model produces results which agree well with respect to existing UV calculations from other published models

  19. Prosopagnosia as a Type of Conversion Disorder

    Directory of Open Access Journals (Sweden)

    Clodagh Power

    2018-01-01

    Full Text Available Background. Conversion disorder is a common and debilitating condition that remains poorly understood. We present a previously undescribed form of conversion disorder to highlight the complexity of the condition and consider the interplay of factors that produce conversion symptoms. Case. A 50-year-old male presented with acquired prosopagnosia and language impairment. Neuropsychological testing indicated right temporal lobe dysfunction. Extensive work-up outruled an organic aetiology. Reactivation of childhood trauma coincided with the onset of his symptoms. Childhood trauma is known to have adverse effects on the developing brain which may affect an individual’s emotional behaviour and coping style. Functional neuroimaging techniques suggest that conversion symptoms may be linked to the disruption of higher order neural circuitry involved in the integration of emotional processing and cortical functioning. Conclusions. We propose that our patient’s adverse childhood experiences led to the development of a particular personality and coping style that “primed” him for a later abnormal emotional and behavioural response when confronted with reminders of his traumatic background. Further interdisciplinary studies are required to further elucidate the neurobiological basis for this condition.

  20. Variations in soil microbial community structure induced by the conversion from paddy fields to upland fields

    Science.gov (United States)

    Dai, X.

    2015-12-01

    Land-use conversion is an important factor influencing the carbon and nitrogen gas exchange between land and atmosphere, and soil microorganisms is main driver of soil carbon and nitrogen gas production. Understanding the effect of land-use conversion on soil microbial communities and its influencing factor is important for greenhouse gas emission reduction and soil organic carbon and nitrogen sequestration and stability. The influence of land use conversion on soil process was undergoing a dynamic change, but little research has been done to understand the effect on soil microbial communities during the initial years after land conversion. In the study, the influences of land-use conversion from double rice cropping (RR) to maize-maize (MM) and soybean-peanut (SP) double cropping systems on soil physical and chemical properties, and microbial community structure was studied after two years of the conversion in southern China. The results showed that land use conversion significantly changed soil properties, microbial communities and biomass. Soil pH significantly decreased by 0.50 and 0.52 after conversion to MM and SP, respectively. Soil TN and NH4-N also significantly decreased by 9%-15% and 60% after conversion to upland fields, respectively. The total PLFAs, bacterial, gram-positive bacterial (G+), gram-negative bacterial (G-) and actinomycetic PLFAs decreased significantly. The ng g-1 soil concentration of monounsaturated chain PLFAs 16:1ω7c and 18:1ω9t were significantly higher at paddy fields than at upland fields. No significant differences in soil properties, microbial communities and biomass were found between conversed MM and SP. Our results indicated that land use conversion, not crop type conversed had a significant effects on soil properties and microbial communities at the initial of land conversion. And soil pH was the key factor regulating the variations in soil microbial community structure after land use conversion from paddy to upland fields.

  1. Advances in low atomic number element analysis by wavelength dispersive x-ray fluorescence spectrometry

    International Nuclear Information System (INIS)

    Vrebos, B.

    1996-01-01

    Traditionally, the analysis of low atomic number has been a chal1enging task for wavelength dispersive x-ray fluorescence spectrometry. Among the most important factors influencing analysis of the low atomic number elements (from Z=11 downwards) are the fluorescence yield, absorption and the dispersion. The effect of each of these factors on the overall performance will be illustrated. The long wavelengths involved (longer than I nm) used to pose severe problems concerning the monochromator used. Early instruments relied on lead stearate or Blodgett Langmuir soap films for the diffraction of the characteristic radiation. Nowadays, synthetic multilayers are commonly used. The performance of these multilayers is determined by the reflectivity, the resolution and the absorption of the characteristic radiation to be diffracted. These parameters can be optimised by adequately selecting the composition of the materials involved. The sensitivity of the modem instruments is sufficient to allow quantitative analysis. However, this aspect of WDS XRF is still met with considerable scepticism. Examples of quantitative analysis will be given to illustrate the current capability

  2. Spectral filter for splitting a beam with electromagnetic radiation having wavelengths in the extreme ultraviolet (EUV) or soft X-Ray (Soft X) and the infrared (IR) wavelength range

    NARCIS (Netherlands)

    van Goor, F.A.; Bijkerk, Frederik; van den Boogaard, Toine; van den Boogaard, A.J.R.; van der Meer, R.

    2012-01-01

    Spectral filter for splitting the primary radiation from a generated beam with primary electromagnetic radiation having a wavelength in the extreme ultraviolet (EUV radiation) or soft X-ray (soft X) wavelength range and parasitic radiation having a wavelength in the infrared wavelength range (IR

  3. Conversion growth of Protestant churches in Thailand

    NARCIS (Netherlands)

    Visser, M

    2008-01-01

    This study set out to answer the question what factors are conducive for church growth through conversion in Protestant Thai churches. After 180 years of unhindered Protestant missionary activity only 0.3% of ethnic Thai, about 185,000 people, have become Protestants. Though small, ethnic Thai

  4. The wavelength dependence of polarization in NGC 2023

    International Nuclear Information System (INIS)

    Rolph, C. D.; Scarrott, S. M.

    1989-01-01

    NGC 2023 is a bright reflection nebula illuminated by the central star HD37903. At 2 microns the nebula is seen solely by reflected light from the central star but in the NIR there is excess radiation that is supposed to arise from thermal emission from a population of small grains (Sellgren, 1984). The unexpectedly high surface brightness at R and I wavelengths has led to the suggestion that even at these wavelengths there is a significant contribution from this thermal emission process (Witt, Schild, and Kraiman, 1984). If the nebula is seen by reflected starlight then this radiation will be linearly polarized. The level of polarization depends on the scattering geometry, grain size distribution, etc., and is typically 20 to 40 percent for nebulae such as NGC 1999 which is morphologically similar to NGC 2023. If, in any waveband, there is a contribution of radiation from emission processes this radiation will be unpolarized and will serve to dilute the scattered radiation to give a lower level of observed polarization. A study of the wavelength dependence of polarization in nebulae in which there may be thermal emission from grains will indicate the contribution from this process to the total luminosity. Polarization maps were produced in BVRI wavebands for the NGC 2023 nebulosity which confirm that at all wavelengths it is a reflection nebula illuminated by a central star. The wavelength dependence of polarization at representative points in the nebula and in a scatter plot of polarization in V and I wavebands at all points at which measurements are given. Results indicate that throughout the nebula there is a general trend for the level of polarization to increase with wavelength and that maximum levels of polarization occur at the longest wavelengths. No evidence is seen in the data for any significant contribution from the thermal emission from grains in the BVRI luminosity of NGC 2023

  5. Design and analysis of Helium Brayton cycle for energy conversion system of RGTT200K

    International Nuclear Information System (INIS)

    Ignatius Djoko Irianto

    2016-01-01

    The helium Brayton cycle for the design of cogeneration energy conversion system for RGTT200K have been analyzed to obtain the higher thermal efficiency and energy utilization factor. The aim of this research is to analyze the potential of the helium Brayton cycle to be implemented in the design of cogeneration energy conversion system of RGTT200K. Three configuration models of cogeneration energy conversion systems have been investigated. In the first configuration model, an intermediate heat exchanger (IHX) is installed in series with the gas turbine, while in the second configuration model, IHX and gas turbines are installed in parallel. The third configuration model is similar to the first configuration, but with two compressors. Performance analysis of Brayton cycle used for cogeneration energy conversion system of RGTT200K has been done by simulating and calculating using CHEMCAD code. The simulation result shows that the three configuration models of cogeneration energy conversion system give the temperature of thermal energy in the secondary side of IHX more than 800 °C at the reactor coolant mass flow rate of 145 kg/s. Nevertheless, the performance parameters, which include thermal efficiency and energy utilization factor (EUF), are different for each configuration model. By comparing the performance parameter in the three configurations of helium Brayton cycle for cogeneration energy conversion systems RGTT200K, it is found that the energy conversion system with a first configuration has the highest thermal efficiency and energy utilization factor (EUF). Thermal efficiency and energy utilization factor for the first configuration of the reactor coolant mass flow rate of 145 kg/s are 35.82 % and 80.63 %. (author)

  6. Spontaneous and radiation induced gene conversion in Saccharomyces cerevisiae

    International Nuclear Information System (INIS)

    Rao, B.S.; Murthy, M.S.S.

    1977-01-01

    Spontaneous and radiation induced gene conversion to arginine independence was studied in a heteroallelic diploid strain of yeast Saccharomyces cerevisiae BZ 34. When stationary phase cells were incubated in phosphate buffer (pH 7 ) at 30 0 C under aerated condition for 48 hours, the conversion frequency increased by a factor of about 1000 times the background. This was found to be so even when the cells were incubated in saline (0.85%) or distilled water. Various conditions influencing this enhancement have been investigated. Conversion frequency enhancement was not significant under anoxic conditions and was absent at low temperatures and in log phase cells. Caffeine could inhibit this enhancement when present in the suspension medium. These results can be explained on the basis of the induction of meiosis in cells held in buffer. Microscopic examination confirmed this view. Under conditions not favourable for the onset of meiosis there is no significant enhancement in conversion frequency. In stationary phase cells exposed to series of gamma doses, the conversion frequency increases with dose. Post irradiation incubation in buffer further increases the conversion frequency. However, the increase expressed as the ratio of the conversion frequency on buffer holding to that on immediate plating decreased with increasing dose. This decrease in enhancement with increasing dose may be due to the dose dependent inhibition of meiosis. (author)

  7. Long wavelength scintillators for fiber-optic applications

    International Nuclear Information System (INIS)

    Lyons, P.B.; Franks, L.; Lutz, S.; Flournoy, J.; Fullman, E.

    1980-01-01

    The use of fiber optics in plasma diagnostics has spurred the development of long wavelength scintillators with fast temporal characteristics. In this paper we describe several new liquid scintillator systems with fluorescent emissions maxima up to 730 nm. Subnanosecond scintillator FWHM response times have been obtained by the operation of liquid scintillators at elevated temperatures. Data on fiber system sensitivity versus fiber length and scintillator emission wavelength will be presented

  8. SPLASH-SXDF Multi-wavelength Photometric Catalog

    Science.gov (United States)

    Mehta, Vihang; Scarlata, Claudia; Capak, Peter; Davidzon, Iary; Faisst, Andreas; Hsieh, Bau Ching; Ilbert, Olivier; Jarvis, Matt; Laigle, Clotilde; Phillips, John; Silverman, John; Strauss, Michael A.; Tanaka, Masayuki; Bowler, Rebecca; Coupon, Jean; Foucaud, Sébastien; Hemmati, Shoubaneh; Masters, Daniel; McCracken, Henry Joy; Mobasher, Bahram; Ouchi, Masami; Shibuya, Takatoshi; Wang, Wei-Hao

    2018-04-01

    We present a multi-wavelength catalog in the Subaru/XMM-Newton Deep Field (SXDF) as part of the Spitzer Large Area Survey with Hyper-Suprime-Cam (SPLASH). We include the newly acquired optical data from the Hyper-Suprime-Cam Subaru Strategic Program, accompanied by IRAC coverage from the SPLASH survey. All available optical and near-infrared data is homogenized and resampled on a common astrometric reference frame. Source detection is done using a multi-wavelength detection image including the u-band to recover the bluest objects. We measure multi-wavelength photometry and compute photometric redshifts as well as physical properties for ∼1.17 million objects over ∼4.2 deg2, with ∼800,000 objects in the 2.4 deg2 HSC-Ultra-Deep coverage. Using the available spectroscopic redshifts from various surveys over the range of 0 fraction of 3.2%. The SPLASH-SXDF catalog is a valuable, publicly available resource, perfectly suited for studying galaxies in the early universe and tracing their evolution through cosmic time.

  9. A review on photo-thermal catalytic conversion of carbon dioxide

    Directory of Open Access Journals (Sweden)

    Ee Teng Kho

    2017-07-01

    Full Text Available The conversion of carbon dioxide into value-added products is of great industrial and environmental interest. However, as carbon dioxide is relatively stable, the input energy required for this conversion is a significant limiting factor in the system's performance. By utilising energy from the sun, through a range of key routes, this limitation can be overcome. In this review, we present a comprehensive and critical overview of the potential routes to harvest the sun's energy, primarily through solar-thermal technologies and plasmonic resonance effects. Focusing on the localised heating approach, this review shortlists and compares viable catalysts for the photo-thermal catalytic conversion of carbon dioxide. Further, the pathways and potential products of different carbon dioxide conversion routes are outlined with the reverse water gas shift, methanation, and methanol synthesis being of key interest. Finally, the challenges in implementing such systems and the outlook to the future are detailed. Keywords: Carbon dioxide conversion, Photo-thermal, Plasmonic catalysis, Solar thermal

  10. Experimental determination of the slow-neutron wavelength distribution

    DEFF Research Database (Denmark)

    Lebech, Bente; Mikke, K.; Sledziewska-Blocka, D.

    1970-01-01

    Different experiments for determining the slow-neutron wavelength distribution in the region 227-3 meV have been carried out, and the results compared. It is concluded that the slow-neutron wave-length distribution can be determined accurately by elastic scattering on a pure incoherent or a pure...

  11. Multi-wavelength lasers using AWGs

    NARCIS (Netherlands)

    Besten, den J.H.

    2003-01-01

    Multiwavelength lasers using AWGs can be used as digitally tunable lasers with simple channel selection, and for generating multiple wavelengths simultanously. In this paper a number of different configurations is reviewed.

  12. NOLM-based all-optical 40 Gbit/s format conversion through sum-frequency generation (SFG) in a PPLN waveguide

    Science.gov (United States)

    Wang, Jian; Sun, Junqiang

    2005-11-01

    A novel all-optical format conversion scheme from NRZ to RZ based on sum-frequency generation (SFG) in a periodically poled LiNbO 3 (PPLN) waveguide is proposed, using a nonlinear optical loop mirror (NOLM). The conversion mechanism relies on the combination of attenuation and nonlinear phase shift induced on the clockwise signal field during the SFG process. The SFG between pump, and co- and counter- propagating signals in the PPLN waveguide are numerically studied, showing that counter-propagating SFG can be ignored when quasi-phase matching (QPM) for SFG during co-propagating interaction. The nonlinear phase shift induced on the clockwise signal field is analyzed in detail, showing that it is more effective to yield large values for nonlinear phase shift when appropriately phase mismatched for the SFG process. Two tuning schemes are proposed depend on whether the sum-frequency wavelength is variable or fixed. It is found that the latter has a rather wide 3dB signal conversion bandwidth approximately 154nm. Finally, the influence of reversible process of SFG is discussed and the optimum arrangement of pump and signal peak powers is theoretically demonstrated. The result shows that proper power arrangement, pump width, and waveguide length are necessary for achieving a good conversion effect.

  13. Wavelength dependence of the bidirectional reflectance distribution function (BRDF) of beach sands.

    Science.gov (United States)

    Doctor, Katarina Z; Bachmann, Charles M; Gray, Deric J; Montes, Marcos J; Fusina, Robert A

    2015-11-01

    The wavelength dependence of the dominant directional reflective properties of beach sands was demonstrated using principal component analysis and the related correlation matrix. In general, we found that the hyperspectral bidirectional reflectance distribution function (BRDF) of beach sands has weak wavelength dependence. Its BRDF varies slightly in three broad wavelength regions. The variations are more evident in surfaces of greater visual roughness than in smooth surfaces. The weak wavelength dependence of the BRDF of beach sand can be captured using three broad wavelength regions instead of hundreds of individual wavelengths.

  14. Continuous-wave single-frequency laser with dual wavelength at 1064 and 532 nm.

    Science.gov (United States)

    Zhang, Chenwei; Lu, Huadong; Yin, Qiwei; Su, Jing

    2014-10-01

    A continuous-wave high-power single-frequency laser with dual-wavelength output at 1064 and 532 nm is presented. The dependencies of the output power on the transmission of the output coupler and the phase-matching temperature of the LiB(3)O(5) (LBO) crystal are studied. An output coupler with transmission of 19% is used, and the temperature of LBO is controlled to the optimal phase-matching temperature of 422 K; measured maximal output powers of 33.7 W at 1064 nm and of 1.13 W at 532 nm are obtained with optical-optical conversion efficiency of 45.6%. The laser can be single-frequency operated stably and mode-hop-free, and the measured frequency drift is less than 15 MHz in 1 min. The measured Mx2 and My2 for the 1064 nm laser are 1.06 and 1.09, respectively. The measured Mx2 and My2 for the 532 nm laser are 1.12 and 1.11, respectively.

  15. A simple method for estimating the effective dose in dental CT. Conversion factors and calculation for a clinical low-dose protocol

    International Nuclear Information System (INIS)

    Homolka, P.; Kudler, H.; Nowotny, R.; Gahleitner, A.; Wien Univ.

    2001-01-01

    An easily appliable method to estimate effective dose including in its definition the high radio-sensitivity of the salivary glands from dental computed tomography is presented. Effective doses were calculated for a markedly dose reduced dental CT protocol as well as for standard settings. Data are compared with effective doses from the literature obtained with other modalities frequently used in dental care. Methods: Conversion factors based on the weighted Computed Tomography Dose Index were derived from published data to calculate effective dose values for various CT exposure settings. Results: Conversion factors determined can be used for clinically used kVp settings and prefiltrations. With reduced tube current an effective dose for a CT examination of the maxilla of 22 μSv can be achieved, which compares to values typically obtained with panoramic radiography (26 μSv). A CT scan of the mandible, respectively, gives 123 μSv comparable to a full mouth survey with intraoral films (150 μSv). Conclusion: For standard CT scan protocols of the mandible, effective doses exceed 600 μSv. Hence, low dose protocols for dental CT should be considered whenever feasable, especially for paediatric patients. If hard tissue diagnoses is performed, the potential of dose reduction is significant despite the higher image noise levels as readability is still adequate. (orig.) [de

  16. High Power OPO Laser and wavelength-controlled system for 1.6μm CO2-DIAL

    Science.gov (United States)

    Abo, M.; Nagasawa, C.; Shibata, Y.

    2009-12-01

    Unlike the existing 2.0μm CO2-DIAL, a high-energy pulse laser operating in the 1.6μm absorption band of CO2 has not been realized. Quasi phase matching (QPM) devices have high conversion efficiency and high beam quality due to their higher nonlinear optical coefficient. We adapt the PPMgLT crystal as the QPM device. The PPMgLT crystal had 3mm × 3mm apertures, and the periodically poled period was 30.9 μm, with the duty ratio close to the ideal value of 0.5. The beam quality of the pumping laser was exceed M2 ≥1.2. The repetition rate was 400 Hz and the energy was 35 mJ. The pumping laser pulse was injection-seeded by the continuous-wave (CW) fiber laser, which had a narrow spectrum. The pulse pumped the PPMgLT crystal in the ring cavity with a single pass through the dielectric mirror. The PPMgLT crystal was mounted on a copper holder, and the temperature was maintained at 40 °C using a Peltier module. The holder’s temperature was stabilized to within 0.01 °C when the copper holder was covered with a plastic case. The OPO ring cavity was a singly resonant oscillator optimized for the signal wave. Single-frequency oscillation of the PPMgLT OPO was achieved by injection seeding, as described in the following. The injection seeder was a DFB laser having a power of 30mW with a 1MHz oscillation spectrum. Their oscillation wavelength was coarse tuned by temperature and fine tuned by adjusting injection currents. The partial power of the online wavelength was split in the wavelength control unit. We locked the DFB laser as an injection seeder of the online wavelength onto the line center by referencing the fiber coupled multipath gas cell (path length 800mm) containing pure CO2 at a pressure of 700 Torr. Stabilization was estimated to within 1.8MHz rms of the line center of the CO2 absorption line by monitoring the feedback signal of a wavelength-controlled unit. Injection seeding of the PPMgLT OPO was performed by matching the cavity length to the seeder

  17. Wavelength calibration of an imaging spectrometer based on Savart interferometer

    Science.gov (United States)

    Li, Qiwei; Zhang, Chunmin; Yan, Tingyu; Quan, Naicheng; Wei, Yutong; Tong, Cuncun

    2017-09-01

    The basic principle of Fourier-transform imaging spectrometer (FTIS) based on Savart interferometer is outlined. The un-identical distribution of the optical path difference which leads to the wavelength drift of each row of the interferogram is analyzed. Two typical methods for wavelength calibration of the presented system are described. The first method unifies different spectral intervals and maximum spectral frequencies of each row by a reference monochromatic light with known wavelength, and the dispersion compensation of Savart interferometer is also involved. The second approach is based on the least square fitting which builds the functional relation between recovered wavelength, row number and calibrated wavelength by concise equations. The effectiveness of the two methods is experimentally demonstrated with monochromatic lights and mixed light source across the detecting band of the system, and the results indicate that the first method has higher precision and the mean root-mean-square error of the recovered wavelengths is significantly reduced from 19.896 nm to 1.353 nm, while the second method is more convenient to implement and also has good precision of 2.709 nm.

  18. Frequency domain phase retrieval of simultaneous multi-wavelength phase-shifting interferometry

    International Nuclear Information System (INIS)

    Yin, Zhenxing; Zhong, Liyun; Xu, Xiaofei; Zhang, Wangping; Lu, Xiaoxu; Tian, Jindong

    2016-01-01

    In simultaneous multi-wavelength phase-shifting interferometry, we propose a novel frequency domain phase retrieval (FDPR) algorithm. First, using only a one-time phase-shifting operation, a sequence of simultaneous multi-wavelength phase-shifting interferograms (SPSMWIs) are captured by a monochrome charge-coupled device. Second, by performing a Fourier transform for each pixel of SPSMWIs, the wrapped phases of each wavelength can be retrieved from the complex amplitude located in the spectral peak of each wavelength. Finally, the phase of the synthetic wavelength can be obtained by the subtraction between the wrapped phases of a single wavelength. In this study, the principle and the application condition of the proposed approach are discussed. Both the simulation and the experimental result demonstrate the simple and convenient performance of the proposed FDPR approach. (paper)

  19. Uranium conversion; Urankonvertering

    Energy Technology Data Exchange (ETDEWEB)

    Oliver, Lena; Peterson, Jenny; Wilhelmsen, Katarina [Swedish Defence Research Agency (FOI), Stockholm (Sweden)

    2006-03-15

    FOI, has performed a study on uranium conversion processes that are of importance in the production of different uranium compounds in the nuclear industry. The same conversion processes are of interest both when production of nuclear fuel and production of fissile material for nuclear weapons are considered. Countries that have nuclear weapons ambitions, with the intention to produce highly enriched uranium for weapons purposes, need some degree of uranium conversion capability depending on the uranium feed material available. This report describes the processes that are needed from uranium mining and milling to the different conversion processes for converting uranium ore concentrate to uranium hexafluoride. Uranium hexafluoride is the uranium compound used in most enrichment facilities. The processes needed to produce uranium dioxide for use in nuclear fuel and the processes needed to convert different uranium compounds to uranium metal - the form of uranium that is used in a nuclear weapon - are also presented. The production of uranium ore concentrate from uranium ore is included since uranium ore concentrate is the feed material required for a uranium conversion facility. Both the chemistry and principles or the different uranium conversion processes and the equipment needed in the processes are described. Since most of the equipment that is used in a uranium conversion facility is similar to that used in conventional chemical industry, it is difficult to determine if certain equipment is considered for uranium conversion or not. However, the chemical conversion processes where UF{sub 6} and UF{sub 4} are present require equipment that is made of corrosion resistant material.

  20. Chirp and temperature effects in parametric down conversion from crystals pumped at 800 nm

    Science.gov (United States)

    Sánchez-Lozano, X.; Wiechers, C.; Lucio, J. L.

    2018-04-01

    We consider spontaneous parametric down conversion from aperiodic poled crystals pumped at 800 nm. Our analyses account the effect of internal and external parameters, where, in the former, we include the crystal chirp and length, while in the latter temperature, also the pump chirp and other beam properties. The typical distribution produced is a pop-tab like structure in frequency-momentum space, and our results show that this system is a versatile light source, appropriated to manipulate the frequency and transverse momentum properties of the light produced. We briefly comment on the potential usefulness of the types of telecom wavelength light produced, in particular for quantum information applications.

  1. A dual-wavelength tunable laser with superimposed fiber Bragg gratings

    International Nuclear Information System (INIS)

    Álvarez-Tamayo, R I; Durán-Sánchez, M; Pottiez, O; Ibarra-Escamilla, B; Kuzin, E A; Cruz, J L; Andrés, M V

    2013-01-01

    We report a dual-wavelength tunable fiber laser. The cavity is formed by two superimposed fiber Bragg gratings (FBGs) and a temperature tunable high-birefringence fiber optical loop mirror (FOLM). FBGs with wavelengths of 1548.5 and 1538.5 nm were printed in the same section of a fiber using two different masks. The superimposed FBGs were placed on a mechanical mount that allows stretch or compression of the FBGs. As a result of the FBG strain both lines are shifted simultaneously. Dual-wavelength generation requires a fine adjustment of the cavity loss for both wavelengths. (paper)

  2. Absolute analytical prediction of photonic crystal guided mode resonance wavelengths

    DEFF Research Database (Denmark)

    Hermannsson, Pétur Gordon; Vannahme, Christoph; Smith, Cameron

    2014-01-01

    numerically with methods such as rigorous coupled wave analysis. Here it is demonstrated how the absolute resonance wavelengths of such structures can be predicted by analytically modeling them as slab waveguides in which the propagation constant is determined by a phase matching condition. The model...... is experimentally verified to be capable of predicting the absolute resonance wavelengths to an accuracy of within 0.75 nm, as well as resonance wavelength shifts due to changes in cladding index within an accuracy of 0.45 nm across the visible wavelength regime in the case where material dispersion is taken...

  3. Phase and fringe order determination in wavelength scanning interferometry.

    Science.gov (United States)

    Moschetti, Giuseppe; Forbes, Alistair; Leach, Richard K; Jiang, Xiang; O'Connor, Daniel

    2016-04-18

    A method to obtain unambiguous surface height measurements using wavelength scanning interferometry with an improved repeatability, comparable to that obtainable using phase shifting interferometry, is reported. Rather than determining the conventional fringe frequency-derived z height directly, the method uses the frequency to resolve the fringe order ambiguity, and combine this information with the more accurate and repeatable fringe phase derived z height. A theoretical model to evaluate the method's performance in the presence of additive noise is derived and shown to be in good agreement with experiments. The measurement repeatability is improved by a factor of ten over that achieved when using frequency information alone, reaching the sub-nanometre range. Moreover, the z-axis non-linearity (bleed-through or ripple error) is reduced by a factor of ten. These order of magnitude improvements in measurement performance are demonstrated through a number of practical measurement examples.

  4. Wavelength dependence of the effects of turbulence on average refraction angles in occultations by planetary atmospheres

    International Nuclear Information System (INIS)

    Haugstad, B.S.; Eshleman, V.R.

    1979-01-01

    Two recent adjacently published papers on the average effects of turbulence in radio and optical occultation studies of planetary atmospheres appear to disagree on the question of wavelength dependence. It is demonstrated here that in deriving a necessary condition for the applicability of their method. Hubbard and Jokipii neglect a factor which is proportional to the square of the ratio of the atmospheric or local Fresnel zone radius and the inner scale of turbulence. They also fail to establish sufficient conditions, thereby omitting as a further factor the square of the ratio of atmospheric scale height and the local Fresnel zone radius. The total descrepancy, which numerically is typically within several orders of magnitude of 10 11 for radio and 10 7 for optical occultations, means that their results correspond to geometrical optics and not to wave optics as claimed. Thus their results are inherently inapplicable in a discussion of the wavelength dependence of any parameter, such as the bias in the average refraction angle treated by Eshleman and Haugstad. We note that for power spectra characterized by the (--p) exponent of the turbulence wavenumber, the average turbulence-induced bias in refraction angles depends on the radiation wavelength as lambda/sup( p/--4)/2, or as lambda/sup en-dash1/6/ for Kolmogorov turbulence. Other features of the Hubbard-Jokipii analysis are also discussed

  5. Local Strategy Combined with a Wavelength Selection Method for Multivariate Calibration

    Directory of Open Access Journals (Sweden)

    Haitao Chang

    2016-06-01

    Full Text Available One of the essential factors influencing the prediction accuracy of multivariate calibration models is the quality of the calibration data. A local regression strategy, together with a wavelength selection approach, is proposed to build the multivariate calibration models based on partial least squares regression. The local algorithm is applied to create a calibration set of spectra similar to the spectrum of an unknown sample; the synthetic degree of grey relation coefficient is used to evaluate the similarity. A wavelength selection method based on simple-to-use interactive self-modeling mixture analysis minimizes the influence of noisy variables, and the most informative variables of the most similar samples are selected to build the multivariate calibration model based on partial least squares regression. To validate the performance of the proposed method, ultraviolet-visible absorbance spectra of mixed solutions of food coloring analytes in a concentration range of 20–200 µg/mL is measured. Experimental results show that the proposed method can not only enhance the prediction accuracy of the calibration model, but also greatly reduce its complexity.

  6. Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography.

    Science.gov (United States)

    Trattner, Sigal; Halliburton, Sandra; Thompson, Carla M; Xu, Yanping; Chelliah, Anjali; Jambawalikar, Sachin R; Peng, Boyu; Peters, M Robert; Jacobs, Jill E; Ghesani, Munir; Jang, James J; Al-Khalidi, Hussein; Einstein, Andrew J

    2018-01-01

    This study sought to determine updated conversion factors (k-factors) that would enable accurate estimation of radiation effective dose (ED) for coronary computed tomography angiography (CTA) and calcium scoring performed on 12 contemporary scanner models and current clinical cardiac protocols and to compare these methods to the standard chest k-factor of 0.014 mSv·mGy -1 cm -1 . Accurate estimation of ED from cardiac CT scans is essential to meaningfully compare the benefits and risks of different cardiac imaging strategies and optimize test and protocol selection. Presently, ED from cardiac CT is generally estimated by multiplying a scanner-reported parameter, the dose-length product, by a k-factor which was determined for noncardiac chest CT, using single-slice scanners and a superseded definition of ED. Metal-oxide-semiconductor field-effect transistor radiation detectors were positioned in organs of anthropomorphic phantoms, which were scanned using all cardiac protocols, 120 clinical protocols in total, on 12 CT scanners representing the spectrum of scanners from 5 manufacturers (GE, Hitachi, Philips, Siemens, Toshiba). Organ doses were determined for each protocol, and ED was calculated as defined in International Commission on Radiological Protection Publication 103. Effective doses and scanner-reported dose-length products were used to determine k-factors for each scanner model and protocol. k-Factors averaged 0.026 mSv·mGy -1 cm -1 (95% confidence interval: 0.0258 to 0.0266) and ranged between 0.020 and 0.035 mSv·mGy -1 cm -1 . The standard chest k-factor underestimates ED by an average of 46%, ranging from 30% to 60%, depending on scanner, mode, and tube potential. Factors were higher for prospective axial versus retrospective helical scan modes, calcium scoring versus coronary CTA, and higher (100 to 120 kV) versus lower (80 kV) tube potential and varied among scanner models (range of average k-factors: 0.0229 to 0.0277 mSv·mGy -1 cm -1 ). Cardiac k-factors

  7. Frequency conversion of high-intensity, femtosecond laser pulses

    Energy Technology Data Exchange (ETDEWEB)

    Banks, P S

    1997-06-01

    Almost since the invention of the laser, frequency conversion of optical pulses via non- linear processes has been an area of active interest. However, third harmonic generation using ~(~1 (THG) in solids is an area that has not received much attention because of ma- terial damage limits. Recently, the short, high-intensity pulses possible with chirped-pulse amplification (CPA) laser systems allow the use of intensities on the order of 1 TW/cm2 in thin solids without damage. As a light source to examine single-crystal THG in solids and other high field inter- actions, the design and construction of a Ti:sapphire-based CPA laser system capable of ultimately producing peak powers of 100 TW is presented. Of special interest is a novel, all-reflective pulse stretcher design which can stretch a pulse temporally by a factor of 20,000. The stretcher design can also compensate for the added material dispersion due to propagation through the amplifier chain and produce transform-limited 45 fs pulses upon compression. A series of laser-pumped amplifiers brings the peak power up to the terawatt level at 10 Hz, and the design calls for additional amplifiers to bring the power level to the 100 TW level for single shot operation. The theory for frequency conversion of these short pulses is presented, focusing on conversion to the third harmonic in single crystals of BBO, KD*P, and d-LAP (deuterated I-arginine phosphate). Conversion efficiencies of up to 6% are obtained with 500 fs pulses at 1053 nm in a 3 mm thick BBO crystal at 200 GW/cm 2. Contributions to this process by unphasematched, cascaded second harmonic generation and sum frequency generation are shown to be very significant. The angular relationship between the two orders is used to measure the tensor elements of C = xt3)/4 with Crs = -1.8 x 1O-23 m2/V2 and .15Cri + .54Crs = 4.0 x 1O-23 m2/V2. Conversion efficiency in d-LAP is about 20% that in BBO and conversion efficiency in KD*P is 1% that of BBO. It is calculated

  8. Adaptive inversion algorithm for 1 . 5 μm visibility lidar incorporating in situ Angstrom wavelength exponent

    Science.gov (United States)

    Shang, Xiang; Xia, Haiyun; Dou, Xiankang; Shangguan, Mingjia; Li, Manyi; Wang, Chong

    2018-07-01

    An eye-safe 1 . 5 μm visibility lidar is presented in this work considering in situ particle size distribution, which can be deployed in crowded places like airports. In such a case, the measured extinction coefficient at 1 . 5 μm should be converted to that at 0 . 55 μm for visibility retrieval. Although several models have been established since 1962, the accurate wavelength conversion remains a challenge. An adaptive inversion algorithm for 1 . 5 μm visibility lidar is proposed and demonstrated by using the in situ Angstrom wavelength exponent, which is derived from an aerosol spectrometer. The impact of the particle size distribution of atmospheric aerosols and the Rayleigh backscattering of atmospheric molecules are taken into account. Using the 1 . 5 μm visibility lidar, the visibility with a temporal resolution of 5 min is detected over 48 h in Hefei (31 . 83∘ N, 117 . 25∘ E). The average visibility error between the new method and a visibility sensor (Vaisala, PWD52) is 5.2% with the R-square value of 0.96, while the relative error between another reference visibility lidar at 532 nm and the visibility sensor is 6.7% with the R-square value of 0.91. All results agree with each other well, demonstrating the accuracy and stability of the algorithm.

  9. Design of multi-wavelength tunable filter based on Lithium Niobate

    Science.gov (United States)

    Zhang, Ailing; Yao, Yuan; Zhang, Yue; Song, Hongyun

    2018-05-01

    A multi-wavelength tunable filter is designed. It consists of multiple waveguides among multiple waveguide gratings. A pair of electrodes were placed on both sides of each waveguide. The tunable filter uses the electro-optic effect of Lithium Niobate to tune the phase caused by each waveguide. Consequently, the wavelength and wavelength spacing of the filter are tuned by changing external voltages added on the electrode pairs. The tunable property of the filter is analyzed by phase matching condition and transfer-matrix method. Numerical results show that not only multiple wavelengths with narrow bandwidth are tuned with nearly equal spacing by synchronously changing the voltages added on all electrode pairs, but also the number of wavelengths is determined by the number of phase shifts caused by electrode pairs. Furthermore, due to the electro-optic effect of Lithium Niobate, the tuning speed of the filter can reach the order of ns.

  10. Wavelength converter placement in optical networks with dynamic traffic

    DEFF Research Database (Denmark)

    Buron, Jakob Due; Ruepp, Sarah Renée; Wessing, Henrik

    2008-01-01

    We evaluate the connection provisioning performance of GMPLS-controlled wavelength routed networks under dynamic traffic load and using three different wavelength converter placement heuristics. Results show that a simple uniform placement heuristic matches the performance of complex heuristics...

  11. Embodied Conversational Agents in Clinical Psychology

    DEFF Research Database (Denmark)

    Provoost, Simon; Lau, Ho Ming; Ruwaard, Jeroen

    2017-01-01

    BACKGROUND: Embodied conversational agents (ECAs) are computer-generated characters that simulate key properties of human face-to-face conversation, such as verbal and nonverbal behavior. In Internet-based eHealth interventions, ECAs may be used for the delivery of automated human support factors....... OBJECTIVE: We aim to provide an overview of the technological and clinical possibilities, as well as the evidence base for ECA applications in clinical psychology, to inform health professionals about the activity in this field of research. METHODS: Given the large variety of applied methodologies, types...... applications in the treatment of mood, anxiety, psychotic, autism spectrum, and substance use disorders were conducted in databases in the fields of psychology and computer science, as well as in interdisciplinary databases. Studies were included if they conveyed primary research findings on an ECA application...

  12. Wavelength switching in an optical klystron

    International Nuclear Information System (INIS)

    Berryman, K.W.; Smith, T.I.

    1995-01-01

    A symmetric optical klystron consists of two identical undulator sections separated a dispersive section. For a device of a given length, an optical klystron is capable of producing much more bunching, and therefore more gain, than a traditional undulator. Another consequence of introducing dispersion between two undulator sections is that the overall spontaneous radiation pattern results from the interference between the two undulator sections, and as such resembles a standard undulator radiation pattern modulated by a sinusoidal interference term. The presence of several wavelength peaks in the spontaneous lineshape implies an equal number of peaks in the gain spectrum. If the strength of the dispersion section is adjusted to provide nearly equal gain on the two largest of these peaks, then they will compete, and the FEL may switch wavelengths based on noise, cavity length, or other perturbations. We provide the first observations of this behavior, using the FIREFLY system at the Stanford Picosecond FEL Center. In FIREFLY, relative wavelength switching by more than 3%--more than twice the laser linewidth-has been observed by varying dispersion section strength, while at intermediate points stable switching has also been observed as a function of cavity length

  13. Sub-wavelength grating structure on the planar waveguide (Conference Presentation)

    Science.gov (United States)

    Qing-Song, Zhu; Sheng-Hui, Chen

    2016-10-01

    Making progress in recent years, with the technology of the grating, the grating period can be reduced to shrink the size of the light coupler on a waveguide. The working wavelength of the light coupler can be in the range from the near-infrared to visible. In this study , we used E-gun evaporation system with ion-beam-assisted deposition system to fabricate bottom cladding (SiO2), guiding layer (Ta2O5) and Distributed Bragg Reflector(DBR) of the waveguide on the silicon substrate. Electron-beam lithography is used to make sub-wavelength gratings and reflector grating on the planar waveguide which is a coupling device on the guiding layer. The best fabrication parameters were analyzed to deposit the film. The exposure and development times also influenced to fabricate the grating quality. The purpose is to reduce the device size and enhance coupling efficiency which maintain normal incidence of the light . We designed and developed the device using the Finite-Difference Time-Domain (FDTD) method. The grating period, depth, fill factor, film thickness, Distributed Bragg Reflector(DBR) numbers and reflector grating period have been discussed to enhance coupling efficiency and maintained normal incidence of the light. According to the simulation results, when the wavelength is 1300 nm, the coupling grating period is 720 nm and the Ta2O5 film is 460 nm with 360 nm of reflector grating period and 2 layers of Distributed Bragg Reflector, which had the optimum coupling efficiency and normal incidence angle. In the measurement, We successfully measured the TE wave coupling efficiency of the photoresist grating coupling device.

  14. Unconventional fluoride conversion coating preparation and characterization

    Czech Academy of Sciences Publication Activity Database

    Drábiková, J.; Fintová, Stanislava; Tkacz, J.; Doležal, P.; Wasserbauer, J.

    2017-01-01

    Roč. 64, č. 6 (2017), s. 613-619 ISSN 0003-5599 Institutional support: RVO:68081723 Keywords : fluoride conversion coating * magnesium * corrosion Subject RIV: JK - Corrosion ; Surface Treatment of Materials OBOR OECD: Coating and films Impact factor: 0.364, year: 2016 http://www.emeraldinsight.com/doi/abs/10.1108/ACMM-02-2017-1757

  15. Down-conversion emission of Ce3+-Tb3+ co-doped CaF2 hollow spheres and application for solar cells

    Science.gov (United States)

    Cheng, Yufei; Wang, Yongbo; Teng, Feng; Dong, Hua; Chen, Lida; Mu, Jianglong; Sun, Qian; Fan, Jun; Hu, Xiaoyun; Miao, Hui

    2018-03-01

    Luminescent downconversion is a promising way to harvest ultraviolet sunlight and transform it into visible light that can be absorbed by solar cells, and has potential to improve their photoelectric conversion efficiency. In this work, the uniform hollow spheres and well dispersed CaF2 phosphors doped with rare-earth Ce3+ and Tb3+ ions are prepared by a one-step hydrothermal synthesis method. Benefiting from the stronger ability of absorption and emission and excellent transparency property, we demonstrate that the application of the doped nanocrystals can efficiently improve visible light transmittance. The chosen phosphors are added in the SiO2 sols so as to get the anti-reflection coatings with wavelength conversion bi-functional films, promoting the optical transmittance in the visible and near-infrared range which matches with the range of the band gap energy of silicon semiconductor. Optimized photoelectric conversion efficiency of 14.35% and the external quantum efficiency over 70% from 450 to 950 nm are obtained through the silicon solar cells with 0.10 g phosphors coating. Compared with the pure glass devices, the photoelectric conversion efficiency is enhanced by 0.69%. This work indicates that fluorescent downconversion not only can serve as proof of principles for improving photoelectric conversion efficiency of solar cells but also may be helpful to practical application in the future.

  16. Serial QuantiFERON-TB Gold In-Tube assay and tuberculin skin test to diagnose latent tuberculosis in household Mexican contacts: conversion and reversion rates and associated factors using conventional and borderline zone definitions

    Directory of Open Access Journals (Sweden)

    Joel Monárrez-Espino

    2014-11-01

    Full Text Available A cohort of 123 adult contacts was followed for 18‐24 months (86 completed the follow-up to compare conversion and reversion rates based on two serial measures of QuantiFERON (QFT and tuberculin skin test (TST (PPD from TUBERSOL, Aventis Pasteur, Canada for diagnosing latent tuberculosis (TB in household contacts of TB patients using conventional (C and borderline zone (BZ definitions. Questionnaires were used to obtain information regarding TB exposure, TB risk factors and socio-demographic data. QFT (IU/mL conversion was defined as 0.70 (BZ and reversion was defined as ≥0.35 to 10 (BZ and reversion was defined as ≥5 to <5 (C. The QFT conversion and reversion rates were 10.5% and 7% with C and 8.1% and 4.7% with the BZ definitions, respectively. The TST rates were higher compared with QFT, especially with the C definitions (conversion 23.3%, reversion 9.3%. The QFT conversion and reversion rates were higher for TST ≥5; for TST, both rates were lower for QFT <0.35. No risk factors were associated with the probability of converting or reverting. The inconsistency and apparent randomness of serial testing is confusing and adds to the limitations of these tests and definitions to follow-up close TB contacts.

  17. Two-wavelength spatial-heterodyne holography

    Science.gov (United States)

    Hanson, Gregory R.; Bingham, Philip R.; Simpson, John T.; Karnowski, Thomas P.; Voelkl, Edgar

    2007-12-25

    Systems and methods are described for obtaining two-wavelength differential-phase holograms. A method includes determining a difference between a filtered analyzed recorded first spatially heterodyne hologram phase and a filtered analyzed recorded second spatially-heterodyned hologram phase.

  18. Sub-wavelength metamaterial cylinders with multiple dipole resonances

    DEFF Research Database (Denmark)

    Arslanagic, Samel; Breinbjerg, Olav

    2009-01-01

    It has been shown that the sub-wavelength resonances of the individual MTM cylinders also occur for electrically small configurations combining 2 or 4 cylinders. For the 2-and 4-cylinder configurations the overall size is 1/20 and 1/12.5 of the smallest wavelength, respectively. These MTM...... configuration thus offer the possibility for multi-resonant electrically small configurations....

  19. Research with high-power short-wavelength lasers

    International Nuclear Information System (INIS)

    Holzrichter, J.F.; Campbell, E.M.; Lindl, J.D.; Storm, E.

    1985-01-01

    Three important high-temperature, high-density experiments were conducted recently using the 10-TW, short-wavelength Novette laser system at the Lawrence Livermore National Laboratory. These experiments demonstrated successful solutions to problems that arose during previous experiments with long wavelength lasers (lambda greater than or equal to 1μm) in which inertial confinement fusion (ICF), x-ray laser, and other high-temperature physics concepts were being tested. The demonstrations were: (1) large-scale plasmas (typical dimensions of up to 1000 laser wavelengths) were produced in which potentially deleterious laser-plasma instabilities were collisionally damped. (2) Deuterium-tritium fuel was imploded to a density of 20 g/cm 3 and a pressure of 10 10 atm. (3) A 700-fold amplification of soft x rays by stimulated emission at 206 and 209 A (62 eV) from Se +24 ions was observed in a laser-generated plasma. Isoelectronic scaling to 155 A (87 eV) in Y +29 was also demonstrated

  20. Free-space wavelength-multiplexed optical scanner demonstration.

    Science.gov (United States)

    Yaqoob, Zahid; Riza, Nabeel A

    2002-09-10

    Experimental demonstration of a no-moving-parts free-space wavelength-multiplexed optical scanner (W-MOS) is presented. With fast tunable lasers or optical filters and planar wavelength dispersive elements such as diffraction gratings, this microsecond-speed scanner enables large several-centimeter apertures for subdegree angular scans. The proposed W-MOS design incorporates a unique optical amplifier and variable optical attenuator combination that enables the calibration and modulation of the scanner response, leading to any desired scanned laser beam power shaping. The experimental setup uses a tunable laser centered at 1560 nm and a 600-grooves/mm blazed reflection grating to accomplish an angular scan of 12.92 degrees as the source is tuned over an 80-nm bandwidth. The values for calculated maximum optical beam divergance, required wavelength resolution, beam-pointing accuracy, and measured scanner insertion loss are 1.076 mrad, 0.172 nm, 0.06 mrad, and 4.88 dB, respectively.