WorldWideScience

Sample records for wave tissue doppler

  1. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 month...

  2. Pulsed-wave tissue Doppler and color tissue Doppler echocardiography: calibration with M-mode, agreement, and reproducibility in a clinical setting

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; Jons, Christian; Fritz-Hansen, Thomas

    2009-01-01

    BACKGROUND: Myocardial velocities can be measured with both pulsed-wave tissue Doppler (PWTD) and color tissue Doppler (CTD) echocardiography. We aimed to (A) to explore which of the two methods better approximates true tissue motion and (B) to examine the agreement and the reproducibility...... of the two methods in a routine clinical setting. METHODS: For Study A, the displacements of 63 basal myocardial segments from 13 patients were examined with M-mode and compared with the velocity-time integral of PWTD and CTD velocities. For Study B, the basal lateral segments from 58 patients were examined...... with PWTD and CTD, and the peak myocardial velocities during systole (Sm), early diastole (Em), and late diastole (Am) were measured. RESULTS: Study A: CTD-based measurements of displacement were 12% lower than M-mode measurements (95% CI: -18%; -6%). PWTD velocity-time integrals measured at the outer edge...

  3. Spectral pulsed-wave tissue Doppler imaging lateral-to-septal delay fails to predict clinical or echocardiographic outcome after cardiac resynchronization therapy

    NARCIS (Netherlands)

    O.I.I. Soliman (Osama Ibrahim Ibrahim); D.A.M.J. Theuns (Dominic); M.L. Geleijnse (Marcel); A. Nemes (Attila); K. Caliskan (Kadir); W.B. Vletter (Wim); L.J.L.M. Jordaens (Luc); F.J. ten Cate (Folkert)

    2007-01-01

    textabstractAims: The current study sought to assess if pre-implantation lateral-to-septal delay (LSD) ≥60 ms assessed by spectral pulsed-wave myocardial tissue Doppler imaging (PW-TDI) could predict successful long-term outcome after cardiac resynchronization therapy (CRT). Methods and results

  4. Pulsed-wave tissue Doppler imaging of the myocardium of cats with induced thyrotoxicosis Doppler tecidual pulsado do miocárdio de gatos com tirotoxicose induzida

    Directory of Open Access Journals (Sweden)

    Daniel Capucho de Oliveira

    2011-06-01

    Full Text Available Left ventricular myocardial motion was quantified using pulsed-wave tissue Doppler imaging (PW-TDI in nine adult cats before and after thyrotoxicosis induction. In order to induce thyrotoxicosis, all cats were given 150µg kg-1 of levothyroxine sodium as a single oral dose each day for 10 weeks. PW-TDI examinations were performed immediately before the induction and by the end of the experimental protocol. An increase in myocardial motion velocity was documented at the interventricular septum level, demonstrated by an elevation in systolic (Sa, and early (Ea and late (Aa diastolic waves (PA velocidade de movimentação miocárdica do ventrículo esquerdo foi quantificada por meio de exames ecocardiográficos com Doppler tecidual pulsado (PW-TDI em nove gatos adultos antes e após indução à tirotoxicose. Para indução da tirotoxicose, todos os gatos receberam doses diárias de 150mg kg-1 de levotiroxina sódica, por via oral, durante 10 semanas. Os exames de PW-TDI foram realizados imediatamente antes da indução e ao final do protocolo experimental. Uma elevação na velocidade de movimentação miocárdica foi documentada ao nível do septo interventricular, demonstrado por um aumento das ondas sistólica (Sa e diastólicas (Ea e Aa; P<0,05. No entanto, nenhuma alteração nos valores de Sa, Ea e Aa foi encontrada ao nível da parede livre do ventrículo esquerdo. A frequência cardíaca aumentou significativamente entre os momentos experimentais, sendo que três animais apresentaram fusão das ondas Aa e Ea ao final do experimento. O protocolo experimental utilizado neste estudo causou alterações na velocidade de movimentação do miocárdio ventricular esquerdo, mas sem causar danos à função diastólica do ventrículo esquerdo.

  5. The impact of tissue Doppler index E/e' ratio on instantaneous wave-free ratio.

    Science.gov (United States)

    Arashi, Hiroyuki; Yamaguchi, Junichi; Ri, Tonre; Otsuki, Hisao; Nakao, Masashi; Kamishima, Kazuho; Jujo, Kentaro; Minami, Yuichiro; Ogawa, Hiroshi; Hagiwara, Nobuhisa

    2018-03-01

    The instantaneous wave-free ratio (iFR) is a vasodilator-free, invasive pressure wire index of the functional severity of coronary stenosis and is calculated under resting conditions. In a recent study, iFR was found to be more closely linked to coronary flow reserve (CFR) than fractional flow reserve (FFR). E/e' is a surrogate marker of left ventricular (LV) filling pressure and LV diastolic dysfunction. Coronary resting flow was found to be increased in patients with elevated E/e', and higher coronary resting flow was associated with lower CFR. Higher baseline coronary flow induces a greater loss of translesional pressure and may affect iFR. However, no reports have examined the impact of E/e' on iFR. The purpose of this study was to assess the relationship between iFR and E/e' compared with FFR. We retrospectively examined 103 consecutive patients (142 with stenosis) whose iFR, FFR, and E/e' were measured simultaneously. The mean age, LV mass index, and systolic blood pressure of patients with elevated E/e' were higher than those of patients with normal E/e'. Although no significant differences were observed in mean FFR values and % diameter stenosis, the mean iFR value in patients with elevated E/e' was significantly lower than that in patients with normal E/e'. The iFR was negatively correlated with E/e', while there was no correlation between FFR and E/e'. Multivariate analysis showed that E/e' and % diameter stenosis were independent determinants of iFR. E/e' ratio affects iFR values. Our results suggest that FFR mainly reflects the functional severity of the epicardial stenosis whereas iFR could potentially be influenced by not only epicardial stenosis but also other factors related to LV filling pressure or LV diastolic dysfunction. Further research is needed to understand the underlying mechanisms that influence the evaluation of iFR in patients with elevated E/e'. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights

  6. Usefulness of pulse-wave doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT

    International Nuclear Information System (INIS)

    Altinmakas, S.; Dagdeviren, B.; Turkmen, M.; Gursurer, M.; Say, B.; Tezel, T.; Ersek, B.

    2000-01-01

    False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58±8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56±7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 μg/kg/min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and/or left circumflex coronary artery (CX) with narrowing (≥50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E/A ratio was lower in patients with CAD when compared to patients without CAD (0.78±0.2 versus 1.29±0.11 p<0.0001). Also the peak stress E/A ratio of normal cases was significantly higher than patients who had CAD (1.19±0.3 versus 0.78±0.2 p<0.0001). When the cut off point for the E/A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E/A were 89% and 86%, respectively. The peak stress E/A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54%±17 versus 99%±24 p=0

  7. Echocardiographic Assessment of Left Ventricular Function in Healthy Horses and in Horses with Heart Disease Using Pulsed-Wave Tissue Doppler Imaging.

    Science.gov (United States)

    Koenig, T R; Mitchell, K J; Schwarzwald, C C

    2017-03-01

    Assessment of left ventricular (LV) function by tissue Doppler imaging (TDI) is not well established in horses with heart disease. To describe the use of pulsed-wave (PW) TDI for the assessment of LV function, establish reference intervals, investigate effects of mitral regurgitation (MR), aortic regurgitation (AR), and primary myocardial disease (MD), and provide proof of concept for the use of PW TDI in Warmblood horses with heart disease. Thirty healthy horses, 38 horses with MR, 25 with AR, 8 with MD. Echocardiograms were retrospectively analyzed. Reference intervals were calculated. PW TDI indices of healthy horses and horses with MR, AR, and MD were compared by one-way ANOVA and Dunnett's test. A complete set of PW TDI variables could be obtained in 94 of 101 horses. Variables corresponding to isovolumic intervals were most difficult to measure. Valvular regurgitation influenced variables describing isovolumic contraction and ejection. Horses with MD had significantly shortened ET m (-118.5 [-154.1 to -82.9] ms; mean difference [95% CI of difference of means]), increased PEP m /ET m (0.11 [0.05 to 0.17]), prolonged IMP m (0.28 [0.18 to 0.37]), increased S 1 (8.9 [5.2 to 12.6] cm/s), and decreased E 1 (-2.6 [-4.7 to -0.5] cm/s), E m (-14.2 [-19.9 to -8.5] cm/s), and E m /A m ratio (-1.6 [-2.6 to -0.6]). Pulsed-wave TDI might be useful for detection of LV dysfunction in horses with primary MD. The clinical value of TDI in horses with MR and AR remains uncertain. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  8. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    OpenAIRE

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 ...

  9. THE DIAGNOSTIC VALUE OF PULSED WAVE TISSUE DOPPLER IMAGING IN ASYMPTOMATIC BETA- THALASSEMIA MAJOR CHILDREN AND YOUNG ADULTS ; RELATION TO CHEMICAL BIOMARKERS OF LEFT VENTRICULAR FUNCTION AND IRON OVERLOAD .

    Directory of Open Access Journals (Sweden)

    Seham Ragab

    2015-08-01

    Full Text Available Background: Cardiac iron toxicity is the leading cause of death among  β-halassaemia major (TM  patients.  Once  heart failure becomes overt , it will be  difficult to reverse . Objectives: To investigate non overt cardiac dysfunctions  in TM patients using  pulsed wave Tissue Doppler  Imaging (TD I and its relation to the iron overload and brain natruritic peptide (BNP. Methods: Thorough  clinical , conventional echo and  pulsed  wave TDI  parameters were compared between  asymtomatic 25 β-TM  patients  and 20 age and gender matched individuals. Serum ferritin and plasma BNP  levels were assayed by  ELISA .  Results: TM patients had significant higher mitral inflow early diastolic (E wave and  non significant other conventional echo  parameters. Pulsed wave TDI revealed systolic and diastolic dysfunctions in the form of significant higher  isovolumetric contraction time (ICT , ejection time ( E T and  isovolumetric relaxation time (IRT with significantly lower  mitral annulus  early diastolic velocity E` (12.07 ±2.06 vs 15.04±2.65 ,P= 0.003  in patients compared to  controls. Plasma BNP was higher in patients compared to the controls.  Plasma BNP and serum ferritin had significant correlation with each other and with pulsed wave conventional and TDI indices of systolic and diastolic functions.  Patients with E/E` ≥ 8 had  significant higher  serum ferritin  and plasma BNP levels compared to those with E/E` ratio < 8 without difference in Hb levels .Conclusion:  Pulsed wave TDI  is an  important diagnostic tool for latent cardiac dysfunction in iron loaded TM patients and is related to iron overload and BNP .

  10. The Diagnostic Value of Pulsed Wave Tissue Doppler Imaging in Asymptomatic Beta- Thalassemia Major Children and Young Adults; Relation to Chemical Biomarkers of Left Ventricular Function and Iron Overload.

    Science.gov (United States)

    Ragab, Seham M; Fathy, Waleed M; El-Aziz, Walaa FAbd; Helal, Rasha T

    2015-01-01

    Cardiac iron toxicity is the leading cause of death among β-halassaemia major (TM) patients. Once heart failure becomes overt, it is difficult to reverse. To investigate non-overt cardiac dysfunctions in TM patients using pulsed wave Tissue Doppler Imaging (TD I) and its relation to iron overload and brain natriuretic peptide (BNP). Thorough clinical, conventional echo and pulsed wave TDI parameters were compared between asymptomatic 25 β-TM patients and 20 age and gender matched individuals. Serum ferritin and plasma BNP levels were assayed by ELISA. TM patients had significant higher mitral inflow early diastolic (E) wave and non significant other conventional echo parameters. In the patient group, pulsed wave TDI revealed systolic dysfunctions, in the form of significant higher isovolumetric contraction time (ICT), and lower ejection time (E T), with diastolic dysfunction in the form of higher isovolumetric relaxation time (IRT), and lower mitral annulus early diastolic velocity E' (12.07 ±2.06 vs 15.04±2.65, P= 0.003) compared to the controls. Plasma BNP was higher in patients compared to the controls. Plasma BNP and serum ferritin had a significant correlation with each other and with pulsed wave conventional and TDI indices of systolic and diastolic functions. Patients with E/E' ≥ 8 had significant higher serum ferritin and plasma BNP levels compared to those with ratio wave TDI is an important diagnostic tool for latent cardiac dysfunction in iron-loaded TM patients and is related to iron overload and BNP.

  11. Low-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking

    Directory of Open Access Journals (Sweden)

    Armstrong J. W.

    2006-01-01

    Full Text Available This paper discusses spacecraft Doppler tracking, the current-generation detector technology used in the low-frequency (~millihertz gravitational wave band. In the Doppler method the earth and a distant spacecraft act as free test masses with a ground-based precision Doppler tracking system continuously monitoring the earth-spacecraft relative dimensionless velocity $2 Delta v/c = Delta u/ u_0$, where $Delta u$ is the Doppler shift and $ u_0$ is the radio link carrier frequency. A gravitational wave having strain amplitude $h$ incident on the earth-spacecraft system causes perturbations of order $h$ in the time series of $Delta u/ u_0$. Unlike other detectors, the ~1-10 AU earth-spacecraft separation makes the detector large compared with millihertz-band gravitational wavelengths, and thus times-of-flight of signals and radio waves through the apparatus are important. A burst signal, for example, is time-resolved into a characteristic signature: three discrete events in the Doppler time series. I discuss here the principles of operation of this detector (emphasizing transfer functions of gravitational wave signals and the principal noises to the Doppler time series, some data analysis techniques, experiments to date, and illustrations of sensitivity and current detector performance. I conclude with a discussion of how gravitational wave sensitivity can be improved in the low-frequency band.

  12. Response of a Doppler canceling system to plane gravitational waves

    International Nuclear Information System (INIS)

    Caporali, A.

    1982-01-01

    This paper discusses the interaction of long periodic gravitational waves with a three-link microwave system known as the Doppler canceling system. This system, which was developed for gravitational red-shift experiment, uses one-way and two-way Doppler information to construct the beat signal of two reference oscillators moving with respect to each other. The geometric-optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational-wave space-time. The signature left on the Doppler-canceled beat by bursts and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler canceling system and that of a (NASA) Doppler tracking system which employs two-way, round-trip radio waves. A threefold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences

  13. Cardiac tissue Doppler imaging in sports medicine.

    Science.gov (United States)

    Krieg, Anne; Scharhag, Jürgen; Kindermann, Wilfried; Urhausen, Axel

    2007-01-01

    The differentiation of training-induced cardiac adaptations from pathological conditions is a key issue in sports cardiology. As morphological features do not allow for a clear delineation of early stages of relevant pathologies, the echocardiographic evaluation of left ventricular function is the technique of first choice in this regard. Tissue Doppler imaging (TDI) is a relatively recent method for the assessment of cardiac function that provides direct, local measurements of myocardial velocities throughout the cardiac cycle. Although it has shown a superior sensitivity in the detection of ventricular dysfunction in clinical and experimental studies, its application in sports medicine is still rare. Besides technical factors, this may be due to a lack in consensus on the characteristics of ventricular function in relevant conditions. For more than two decades there has been an ongoing debate on the existence of a supernormal left ventricular function in athlete's heart. While results from traditional echocardiography are conflicting, TDI studies established an improved diastolic function in endurance-trained athletes with athlete's heart compared with controls.The influence of anabolic steroids on cardiac function also has been investigated by standard echocardiographic techniques with inconsistent results. The only TDI study dealing with this topic demonstrated a significantly impaired diastolic function in bodybuilders with long-term abuse of anabolic steroids compared with strength-trained athletes without abuse of anabolic steroids and controls, respectively.Hypertrophic cardiomyopathy is the most frequent cause of sudden death in young athletes. However, in its early stages, it is difficult to distinguish from athlete's heart. By means of TDI, ventricular dysfunction in hypertrophic cardiomyopathy can be disclosed even before the development of left ventricular hypertrophy. Also, a differentiation of left ventricular hypertrophy due to hypertrophic

  14. Cardiac Time Intervals by Tissue Doppler Imaging M-Mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; de Knegt, Martina Chantal

    2016-01-01

    PURPOSE: To define normal values of the cardiac time intervals obtained by tissue Doppler imaging (TDI) M-mode through the mitral valve (MV). Furthermore, to evaluate the association of the myocardial performance index (MPI) obtained by TDI M-mode (MPITDI) and the conventional method of obtaining...

  15. Tissue doppler echocardiography for evaluating left ventricular functions in obese

    Directory of Open Access Journals (Sweden)

    Mecnun Çetin

    2013-03-01

    Full Text Available Objective: The aim of this study was to investigate theimpact of childhood obesity on ventricular functions usingtissue Doppler echocardiography.Materials and methods: The mitral tissue Doppler signalswere recorded in the apical four-chamber view, with thesample volume placed at the lateral walls of mitral annulus.The mitral flow was examined with the sample Pulse Dopplerpositioned parallely to flow just at the orifice of the mitralleaflets. Twenty obese (mean age, 161.5±25.8 monthsand 20 healthy children (mean age, 151.2±33.5 monthswere included to this study.Results: Body mass index (BMI was significantly higherin obese group (30.92±6.87. Isovolumic relaxation time(IVRT which is one of the left ventricular (LV diastolicfunction parameters was 66.10±7.30 ms in obese group,and 58.70±9.06 ms in the control group. IVRT was significantlyhigher in the obese group (p=0.007. In obesegroup, the mitral annulus tissue Doppler E velocity wasdecreased, flow velocity was increased and decrement inEm/Am ratio was significant. We found significant negativecorrelation between BMI and LV Em/Am ratio. Myocardialperformance index (MPI in obese group and control groupwas 0.50±0.07 and 0.41±0.04, respectively (p<0.001.Between MPI and LV Em/Am ratio there was a significantnegative correlation while MPI showed positive correlationwith BMI. In obese group septal and LV posterior wall thicknesswas shown to be significantly increased compared tothe control group (p<0.001.Conclusion: Our findings, may be important for determinationof the relationship between obesity and cardiovascularrisk factors in children. Tissue Doppler echocardiographicimaging may be useful in revealing this relationship.Key words: obesity, doppler echocardiography, ventricular dysfunction

  16. Synchronous ultrasonic Doppler imaging of magnetic microparticles in biological tissues

    Energy Technology Data Exchange (ETDEWEB)

    Pyshnyi, Michael Ph. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation); Kuznetsov, Oleg A. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation)], E-mail: kuznetsov_oa@yahoo.com; Pyshnaya, Svetlana V.; Nechitailo, Galina S.; Kuznetsov, Anatoly A. [Institute of Biochemical Physics, Russian Academy of Sciences, Kosygin St. 4, Moscow 119991 (Russian Federation)

    2009-05-15

    We considered applicability of acoustic imaging technology for the detection of magnetic microparticles and nanoparticles inside soft biological tissues. Such particles are widely used for magnetically targeted drug delivery and magnetic hyperthermia. We developed a new method of ultrasonic synchronous tissue Doppler imaging with magnetic modulation for in vitro and in vivo detection and visualization of magnetic ultradisperse objects in soft tissues. Prototype hardware with appropriate software was produced and the method was successfully tested on magnetic microparticles injected into an excised pig liver.

  17. Synchronous ultrasonic Doppler imaging of magnetic microparticles in biological tissues

    International Nuclear Information System (INIS)

    Pyshnyi, Michael Ph.; Kuznetsov, Oleg A.; Pyshnaya, Svetlana V.; Nechitailo, Galina S.; Kuznetsov, Anatoly A.

    2009-01-01

    We considered applicability of acoustic imaging technology for the detection of magnetic microparticles and nanoparticles inside soft biological tissues. Such particles are widely used for magnetically targeted drug delivery and magnetic hyperthermia. We developed a new method of ultrasonic synchronous tissue Doppler imaging with magnetic modulation for in vitro and in vivo detection and visualization of magnetic ultradisperse objects in soft tissues. Prototype hardware with appropriate software was produced and the method was successfully tested on magnetic microparticles injected into an excised pig liver.

  18. Assessment of right ventricular systolic function by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjærgaard, Jesper

    2012-01-01

    This thesis summarizes a series of studies performed in order to assess the clinical usefulness of a novel echocardiographic technology that allows non-invasive assessment of regional right ventricular myocardial velocities and deformation: tissue Doppler echocardiography. While the technology...... is a promising tool for improving our understanding of right ventricular hemodynamics, several aspects of the technology must be evaluated. The accuracy and reproducibility of the technology is evaluated in vitro, and normal values, impact of changes in loading of the right ventricle, response to exercise...... on right ventricular hemodynamics: pulmonary embolism, Arrhythmogenic right ventricular cardiomyopathy and pulmonary regurgitation, the latter in an animal model. The conclusions of the thesis are: Color tissue Doppler echocardiography accurately measures velocities, SR and strain in vitro. No systematic...

  19. Pulsed-wave transmitral Doppler do not diagnose moderate acute rejection after heart transplantation

    NARCIS (Netherlands)

    Mannaerts, H. F.; Simoons, M. L.; Balk, A. H.; Tijssen, J.; van der Borden, S. G.; Zondervan, P. E.; Mochtar, B.; Weimar, W.; Roelandt, J. R.

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously

  20. PULSED-WAVE TRANSMITRAL DOPPLER DO NOT DIAGNOSE MODERATE ACUTE REJECTION AFTER HEART-TRANSPLANTATION

    NARCIS (Netherlands)

    MANNAERTS, HF; SIMOONS, ML; BALK, AH; TIJSSEN, J; VANDERBORDEN, SG; ZONDERVAN, PE; MOCHTAR, B; WEIMAR, W; ROELANDT, [No Value

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously

  1. Bubble-Induced Color Doppler Feedback for Histotripsy Tissue Fractionation.

    Science.gov (United States)

    Miller, Ryan M; Zhang, Xi; Maxwell, Adam D; Cain, Charles A; Xu, Zhen

    2016-03-01

    Histotripsy therapy produces cavitating bubble clouds to increasingly fractionate and eventually liquefy tissue using high-intensity ultrasound pulses. Following cavitation generated by each pulse, coherent motion of the cavitation residual nuclei can be detected using metrics formed from ultrasound color Doppler acquisitions. In this paper, three experiments were performed to investigate the characteristics of this motion as real-time feedback on histotripsy tissue fractionation. In the first experiment, bubble-induced color Doppler (BCD) and particle image velocimetry (PIV) analysis monitored the residual cavitation nuclei in the treatment region in an agarose tissue phantom treated with two-cycle histotripsy pulses at [Formula: see text] using a 500-kHz transducer. Both BCD and PIV results showed brief chaotic motion of the residual nuclei followed by coherent motion first moving away from the transducer and then rebounding back. Velocity measurements from both PIV and BCD agreed well, showing a monotonic increase in rebound time up to a saturation point for increased therapy dose. In a second experiment, a thin layer of red blood cells (RBC) was added to the phantom to allow quantification of the fractionation of the RBC layer to compare with BCD metrics. A strong linear correlation was observed between the fractionation level and the time to BCD peak rebound velocity over histotripsy treatment. Finally, the correlation between BCD feedback and histotripsy tissue fractionation was validated in ex vivo porcine liver evaluated histologically. BCD metrics showed strong linear correlation with fractionation progression, suggesting that BCD provides useful quantitative real-time feedback on histotripsy treatment progression.

  2. Mesospheric gravity wave momentum flux estimation using hybrid Doppler interferometry

    Directory of Open Access Journals (Sweden)

    A. J. Spargo

    2017-06-01

    Full Text Available Mesospheric gravity wave (GW momentum flux estimates using data from multibeam Buckland Park MF radar (34.6° S, 138.5° E experiments (conducted from July 1997 to June 1998 are presented. On transmission, five Doppler beams were symmetrically steered about the zenith (one zenith beam and four off-zenith beams in the cardinal directions. The received beams were analysed with hybrid Doppler interferometry (HDI (Holdsworth and Reid, 1998, principally to determine the radial velocities of the effective scattering centres illuminated by the radar. The methodology of Thorsen et al. (1997, later re-introduced by Hocking (2005 and since extensively applied to meteor radar returns, was used to estimate components of Reynolds stress due to propagating GWs and/or turbulence in the radar resolution volume. Physically reasonable momentum flux estimates are derived from the Reynolds stress components, which are also verified using a simple radar model incorporating GW-induced wind perturbations. On the basis of these results, we recommend the intercomparison of momentum flux estimates between co-located meteor radars and vertical-beam interferometric MF radars. It is envisaged that such intercomparisons will assist with the clarification of recent concerns (e.g. Vincent et al., 2010 of the accuracy of the meteor radar technique.

  3. Mesospheric gravity wave momentum flux estimation using hybrid Doppler interferometry

    Science.gov (United States)

    Spargo, Andrew J.; Reid, Iain M.; MacKinnon, Andrew D.; Holdsworth, David A.

    2017-06-01

    Mesospheric gravity wave (GW) momentum flux estimates using data from multibeam Buckland Park MF radar (34.6° S, 138.5° E) experiments (conducted from July 1997 to June 1998) are presented. On transmission, five Doppler beams were symmetrically steered about the zenith (one zenith beam and four off-zenith beams in the cardinal directions). The received beams were analysed with hybrid Doppler interferometry (HDI) (Holdsworth and Reid, 1998), principally to determine the radial velocities of the effective scattering centres illuminated by the radar. The methodology of Thorsen et al. (1997), later re-introduced by Hocking (2005) and since extensively applied to meteor radar returns, was used to estimate components of Reynolds stress due to propagating GWs and/or turbulence in the radar resolution volume. Physically reasonable momentum flux estimates are derived from the Reynolds stress components, which are also verified using a simple radar model incorporating GW-induced wind perturbations. On the basis of these results, we recommend the intercomparison of momentum flux estimates between co-located meteor radars and vertical-beam interferometric MF radars. It is envisaged that such intercomparisons will assist with the clarification of recent concerns (e.g. Vincent et al., 2010) of the accuracy of the meteor radar technique.

  4. Hypercholesterolemia and Myocardial function evaluated via Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Kotaru Pavan

    2009-11-01

    Full Text Available Abstract Objective To establish a link between hypercholesterolemia and myocardial dysfunction. Background Heart failure is a complex disease involving changes in systolic and diastolic function. Newer echocardiographic imaging modalities may be able to detect discreet changes in myocardial function associated with hypercholesterolemia. Therefore we sought to establish a link between hypercholesterolemia and myocardial dysfunction with tissue Doppler imaging (TDI. Methods Twenty-seven rabbits were studied: 7 were fed normal chow (group 1 and 20 a high cholesterol diet (10 with ezetimibe, 1 mg/kg/day; group 2 and 10 without, group 3. Echocardiographic images were obtained under general anesthesia. Serum cholesterol levels were obtained at baseline, 3 and 6 months and myocardial cholesterol levels measured following euthanasia. Results Doppler measurements, including E/A, E'/A' and S' were significantly lower in group 3 compared to both groups 1 and 2 but no significant differences were noted in chamber sizes or ejection fraction among the groups. Average serum cholesterol was higher in group 3 compared to groups 1 and 2 respectively (495 ± 305 mg/dl vs. 114 ± 95 mg/dl and 87 ± 37 mg/dl; p 2 = 0.17 p = 0.04, r2 = 0.37 p = 0.001 and r2 = 0.24 p = 0.01. Conclusion Cholesterol load in the serum and myocardium was significantly associated with decreased systolic and diastolic function by TDI. Moreover, lipid lowering was protective.

  5. Pulsed and Tissue Doppler Echocardiographic Changes in Patients with Thalassemia Major

    Directory of Open Access Journals (Sweden)

    Taysir S. Garadah

    2010-01-01

    Full Text Available Background Doppler echocardiographic studies of left ventricle (LV systolic and diastolic function in patients with β-Thalassemia Major (β-TM had shown different patterns of systolic and diastolic dysfunction. Aim This cross-sectional study was designed to study the LV systolic and diastolic function in patients with β-TM using Pulsed Doppler (PD and Tissue Doppler (TD echocardiography. Methods All patients were evaluated clinically and by echocardiography, The study included patients with β-TM (n = 38, age 15.7 ± 8.9 years compared with an age-matched control group (n = 38, age 15.9 ± 8.9 years. The pulse Doppler indices were normalized for age and heart rate. Results Compared with control patients, M-Mode showed that patients with β-TM have thicker LV septal wall index (0.659 ± 0.23 vs. 0.446 ± 0.219 cm, P ≤ 0.001, posterior wall index (0.659 ± 0.235 vs. 0.437 ± 0.214 cm, P ≤ 0.01, and larger LVEDD index is (3.99 ± 0.48 vs. 2.170 ± 0.57 mm. P = 0.035. Pulsed Doppler showed high LV trans-mitral E wave velocity (70.818 ± 10.139 vs. 57.532 ± 10.139, p = 0.027 and E/A ratio (1.54 vs. 1.23, P ≤ 0.01. The duration of Deceleration time (DT and isovolumic relaxation time (IVRT were significantly shorter in patients with β-TM (150.234 ± 20.0.23 vs. 167.123 ± 19.143 msec, P ≤ 0.01 and (60.647 ± 6.77 vs. 75.474 ± 5.83 msec, P ≤ 0.001, respectively. The ratio of transmitral E wave velocity to the tissue Doppler E wave at the basal septal mitral annulus E/Em – was significantly higher in β-TM group (14.024 ± 2.29 vs. 12.132 ± 1.82, P ≤ 0.01. The Tissue Doppler systolic velocity (Sm and the early diastolic velocity (Em were significantly lower in β-TM group compared to control (4.31 ± 1.2 cm/s vs. 6.95 ± 2.1, P ≤ 0.01 and 4.31 ± 2.7 cm/s vs. 5.82 ± 2.5, P ≤ 0.01 respectively. The tricuspid valve velocity was significantly higher than controls (2.993 ± 0.569 vs. 1.93 ± 0.471 m/sec, respectively, P ≤ 0

  6. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    Science.gov (United States)

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 MHz high-frequency array ultrasound imaging system. Phantom studies show that the Doppler flow mode of the dual mode is capable of measuring the flow velocity from 0.1 to 15 cm s−1 with high accuracy (p-value = 0.974 > 0.05). In the in vivo study of zebrafish, both TD and Doppler flow signals were simultaneously obtained from the zebrafish heart for the first time, and the synchronized valve motions with the blood flow signals were identified. In the longitudinal study on the zebrafish heart regeneration, the parameters for diagnosing the diastolic dysfunction, for example, E/Em < 10, E/A < 0.14 for wild-type zebrafish, were measured, and the type of diastolic dysfunction caused by the amputation was found to be similar to the restrictive filling. The diastolic function was fully recovered within four weeks post-amputation. PMID:25505135

  7. Prognostic value of tissue Doppler imaging for predicting ventricular arrhythmias and cardiovascular mortality in ischaemic cardiomyopathy

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Olsen, Flemming Javier; Storm, Katrine

    2016-01-01

    AIMS: Only 30% of patients receiving an implantable cardioverter defibrillator (ICD) for primary prevention receive appropriately therapy. We sought to investigate the value of tissue Doppler imaging (TDI) to predict ventricular tachycardia (VT), ventricular fibrillation (VF), and cardiovascular...

  8. Quantitation of stress echocardiography by tissue Doppler and strain rate imaging: a dream come true?

    Science.gov (United States)

    Galderisi, Maurizio; Mele, Donato; Marino, Paolo Nicola

    2005-01-01

    Tissue Doppler (TD) is an ultrasound tool providing a quantitative agreement of left ventricular regional myocardial function in different modalities. Spectral pulsed wave (PW) TD, performed online during the examination, measures instantaneous myocardial velocities. By means of color TD, velocity images are digitally stored for subsequent off-line analysis and mean myocardial velocities are measured. An implementation of color TD includes strain rate imaging (SRI), based on post-processing conversion of regional velocities in local myocardial deformation rate (strain rate) and percent deformation (strain). These three modalities have been applied to stress echocardiography for quantitative evaluation of regional left ventricular function and detection of ischemia and viability. They present advantages and limitations. PWTD does not permit the simultaneous assessment of multiple walls and therefore is not compatible with clinical stress echocardiography while it could be used in a laboratory setting. Color TD provides a spatial map of velocity throughout the myocardium but its results are strongly affected by the frame rate. Both color TD and PWTD are also influenced by overall cardiac motion and tethering from adjacent segments and require reference velocity values for interpretation of regional left ventricular function. High frame rate (i.e. > 150 ms) post-processing-derived SRI can potentially overcome these limitations, since measurements of myocardial deformation have not any significant apex-to-base gradient. Preliminary studies have shown encouraging results about the ability of SRI to detect ischemia and viability, in terms of both strain rate changes and/or evidence of post-systolic thickening. SRI is, however, Doppler-dependent and time-consuming. Further technical refinements are needed to improve its application and introduce new ultrasound modalities to overcome the limitations of the Doppler-derived deformation analysis.

  9. Acute Effects of Lateral Thigh Foam Rolling on Arterial Tissue Perfusion Determined by Spectral Doppler and Power Doppler Ultrasound.

    Science.gov (United States)

    Hotfiel, Thilo; Swoboda, Bernd; Krinner, Sebastian; Grim, Casper; Engelhardt, Martin; Uder, Michael; Heiss, Rafael U

    2017-04-01

    Hotfiel, T, Swoboda, B, Krinner, S, Grim, C, Engelhardt, M, Uder, M, and Heiss, R. Acute effects of lateral thigh foam rolling on arterial tissue perfusion determined by spectral Doppler and power Doppler ultrasound. J Strength Cond Res 31(4): 893-900, 2017-Foam rolling has been developed as a popular intervention in training and rehabilitation. However, evidence on its effects on the cellular and physiological level is lacking. The aim of this study was to assess the effect of foam rolling on arterial blood flow of the lateral thigh. Twenty-one healthy participants (age, 25 ± 2 years; height, 177 ± 9 cm; body weight, 74 ± 9 kg) were recruited from the medical and sports faculty. Arterial tissue perfusion was determined by spectral Doppler and power Doppler ultrasound, represented as peak flow (Vmax), time average velocity maximum (TAMx), time average velocity mean (TAMn), and resistive index (RI), and with semiquantitative grading that was assessed by 4 blindfolded investigators. Measurement values were assessed under resting conditions and twice after foam rolling exercises of the lateral thigh (0 and 30 minutes after intervention). The trochanteric region, mid portion, and distal tibial insertion of the lateral thigh were representative for data analysis. Arterial blood flow of the lateral thigh increased significantly after foam rolling exercises compared with baseline (p ≤ 0.05). We detected a relative increase in Vmax of 73.6% (0 minutes) and 52.7% (30 minutes) (p power Doppler scores at all portions revealed increased average grading of 1.96 after intervention and 2.04 after 30 minutes compared with 0.75 at baseline. Our results may contribute to the understanding of local physiological reactions to self-myofascial release.

  10. The association between brain natriuretic peptide and tissue Doppler parameters in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Taliha Öner

    2016-01-01

    Full Text Available In this study, we investigated the association between brain natriuretic peptide (BNP levels and tissue Doppler imaging measurements and also screening for deadly mutations in patients with hypertrophic cardiomyopathy (HCM. We enrolled 20 patients diagnosed with HCM (age:10.7±5 years (1-17, 85% male, weight:42.25±23.10 kg, height:141.80±32.45 cm and 20 age, gender and body weight-matched control subjects. We performed electrocardiography, transthoracic echocardiography, and tissue Doppler echocardiography in each group, as well as genetic tests (for Arg403Gln, Arg453Cys, Arg719Trp and Arg719Gln mutations in MYH7 Exons 13, 14, 19 and BNP in the patients. The patients were divided into two groups according to the presence (Group 1 or absence (Group 2 of left ventricular (LV outflow tract obstruction. QTc dispersion and the LV ejection fraction and left atrial (LA volume index were increased in Group 1. The LA volume index and the mitral and septal E/Ea ratio and septum Z-score were increased while the mitral lateral annulus and septal annulus Ea wave velocities and the mitral and tricuspid E/A ratio were decreased in patients with high levels of BNP compared to those with normal BNP levels. There were no mutations that are associated with increased risk of sudden death found in patients included in this study. In the light of our data, we conclude that such parameters BNP levels above the 98 pg/mL, septal thickness Z-score ˃6, and higher mitral and septal E/Ea ratios can be used for management of patients with HCM according to life-threatening conditions.

  11. Time series analysis of continuous-wave coherent Doppler Lidar wind measurements

    DEFF Research Database (Denmark)

    Sjöholm, Mikael; Mikkelsen, Torben; Mann, Jakob

    2008-01-01

    The influence of spatial volume averaging of a focused 1.55 mu m continuous-wave coherent Doppler Lidar on observed wind turbulence measured in the atmospheric surface layer over homogeneous terrain is described and analysed. Comparison of Lidar-measured turbulent spectra with spectra simultaneou......The influence of spatial volume averaging of a focused 1.55 mu m continuous-wave coherent Doppler Lidar on observed wind turbulence measured in the atmospheric surface layer over homogeneous terrain is described and analysed. Comparison of Lidar-measured turbulent spectra with spectra...

  12. Evaluation of left ventricular function in obese children without hypertension by a tissue Doppler imaging study.

    Science.gov (United States)

    Ghandi, Yazdan; Sharifi, Mehrzad; Habibi, Danial; Dorreh, Fatemeh; Hashemi, Mojtaba

    2018-01-01

    The prevalence of obesity is increasing worldwide. Obese children without hypertension are becoming an important health challenge. Complications of obesity in adults are well established, but in obese children, cardiac dysfunction has not been reported clinically. The present crosssectional study investigates subclinical systolic and diastolic dysfunction using echocardiographic modalities. Twentyfive youngsters with body mass index (BMI) >30 and 25 healthy children with BMI <25 were assigned into case and control group, respectively. In all participants, complete cardiovascular examination, electrocardiography, and echocardiography were fulfilled. Echocardiography surveys included standard, pulsed wave Doppler (PWD), and tissue Doppler imaging (TDI). SPSS software, version 24. The two groups were matched for age and sex. The resting heart rate and blood pressure were markedly higher in the obese group ( P = 0.0001) though they were within the normal range in either category. Ejection fraction in the two groups was similar. Left ventricular (LV) mass ( P = 0.0001), LV mass index ( P = 0.029), left atrialtoaortic diameter ratio ( P = 0.0001), and LV enddiastolic diameter ( P = 0.008) were significantly greater in the case group, indicating cardiomegaly and subclinical systolic and diastolic dysfunction. Except for the aortic velocity, all PWD variables were considerably lower in the case group, suggesting subclinical diastolic dysfunction. All TDI parameters varied significantly between the two categories. There was a direct correlation between isovolumetric relaxation time and BMI. Obesity in children without hypertension is associated with subclinical systolic and diastolic cardiac dysfunction. We propose the evaluation of blood pressure as well as myocardial performance using PWD and TDI in all obese children without hypertension, regularly.

  13. Noninvasive Doppler tissue measurement of pulmonary artery compliance in children with pulmonary hypertension.

    Science.gov (United States)

    Dyer, Karrie; Lanning, Craig; Das, Bibhuti; Lee, Po-Feng; Ivy, D Dunbar; Valdes-Cruz, Lilliam; Shandas, Robin

    2006-04-01

    We have shown previously that input impedance of the pulmonary vasculature provides a comprehensive characterization of right ventricular afterload by including compliance. However, impedance-based compliance assessment requires invasive measurements. Here, we develop and validate a noninvasive method to measure pulmonary artery (PA) compliance using ultrasound color M-mode (CMM) Doppler tissue imaging (DTI). Dynamic compliance (C(dyn)) of the PA was obtained from CMM DTI and continuous wave Doppler measurement of the tricuspid regurgitant velocity. C(dyn) was calculated as: [(D(s) - D(d))/(D(d) x P(s))] x 10(4); where D(s) = systolic diameter, D(d) = diastolic diameter, and P(s) = systolic pressure. The method was validated both in vitro and in 13 patients in the catheterization laboratory, and then tested on 27 pediatric patients with pulmonary hypertension, with comparison with 10 age-matched control subjects. C(dyn) was also measured in an additional 13 patients undergoing reactivity studies. Instantaneous diameter measured using CMM DTI agreed well with intravascular ultrasound measurements in the in vitro models. Clinically, C(dyn) calculated by CMM DTI agreed with C(dyn) calculated using invasive techniques (23.4 +/- 16.8 vs 29.1 +/- 20.6%/100 mm Hg; P = not significant). Patients with pulmonary hypertension had significantly lower peak wall velocity values and lower C(dyn) values than control subjects (P < .01). C(dyn) values followed an exponentially decaying relationship with PA pressure, indicating the nonlinear stress-strain behavior of these arteries. Reactivity in C(dyn) agreed with reactivity measured using impedance techniques. The C(dyn) method provides a noninvasive means of assessing PA compliance and should be useful as an additional measure of vascular reactivity subsequent to pulmonary vascular resistance in patients with pulmonary hypertension.

  14. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  15. The Assessment of Left Ventricular Time-Varying Radius Using Tissue Doppler Imaging

    Directory of Open Access Journals (Sweden)

    Fardin Mirbolouk

    2012-03-01

    Full Text Available Background: Left ventricular twist/torsion is believed to be a sensitive indicator of systolic and diastolic performance. To obtain circumferential rotation using tissue Doppler imaging, we need to estimate the time-varying radius of the left ventricle throughout the cardiac cycle to convert the tangential velocity into angular velocity. Objectives: The aim of this study was to investigate accuracy of measured LV radius using tissue Doppler imaging throughout the cardiac cycle compared to two-dimensional (2D imaging. Methods: A total of 35 subjects (47±12 years old underwent transthoracic echocardiographic standard examinations. Left ventricular radius during complete cardiac cycle measured using tissue Doppler and 2D-imaging at basal and apical short axis levels. For this reason, the 2D-images and velocity-time data derived and transferred to a personal computer for off-line analysis. 2D image frames analyzed via a program written in the MATLAB software. Velocity-time data from anteroseptal at basal level (or anterior wall at apical level and posterior walls transferred to a spreadsheet Excel program for the radius calculations. Linear correlation and Bland-Altman analysis were calculated to assess the relationships and agreements between the tissue Doppler and 2D-measured radii throughout the cardiac cycle. Results: There was significant correlation between tissue Doppler and 2D-measured radii and the Pearson correlation coefficients were 0.84 to 0.97 (P<0.05. Bland-Altman analysis by constructing the 95% limits of agreement showed that the good agreements existed between the two methods. Conclusion: It can be concluded from our experience that the tissue Doppler imaging can reasonably estimate radius of the left ventricle throughout the cardiac cycle.

  16. Full-wave Simulation of Doppler Reflectometry in the Presence of Turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Lechte, C. [Institut fur Plasmaforschung, Universitat Stuttgart, Stuttgart (Germany)

    2011-07-01

    Doppler reflectometry is a microwave plasma diagnostic well suited for density fluctuation measurement. A meaningful interpretation of Doppler reflectometry measurements necessitates the analysis of the wave propagation in the plasma using simulations methods. While the beam path can usually be reconstructed with beam tracing methods, the modeling of the scattering process demands the use of wave simulation codes. Furthermore, in the presence of strong density fluctuations, the response from the plasma is dominated by dispersion and multiple scattering, and hence becomes non-linear. IPF-FD3D is the finite difference time domain code used to investigate the dependence of the scattering efficiency on the various plasma conditions. It uses the full set of Maxwell equations and the electron equation of motion in a cold plasma. First results in slab geometry indicate a strong dependence of the scattering efficiency on the density gradient, the incident angle, and the wave polarisation. Further complications arise with the introduction of broadband turbulent fluctuations, where additional knowledge of the radial spectrum is necessary to reconstruct the full fluctuation spectrum from Doppler reflectometry measurements. This paper presents the reconstruction of the turbulent fluctuation spectrum from simulated Doppler reflectometry measurements in slab geometry. Two cases of analytical turbulence in slab geometry are presented where the fluctuation wavenumber spectrum was recovered. It is planned to extend these investigations to X mode polarization and to supplement actual fusion experiments

  17. Tissue Doppler echocardiography reveals impaired cardiac function in patients with reversible ischaemia

    DEFF Research Database (Denmark)

    Hoffmann, Søren; Mogelvang, Rasmus; Sogaard, Peter

    2011-01-01

    AIMS: To determine if echocardiographic tissue Doppler imaging (TDI) performed at rest detects reduced myocardial function in patients with reversible ischaemia. METHODS AND RESULTS: Eighty-four patients with angina pectoris, no previous history of ischaemic heart disease and normal left ventricu...

  18. Systolic and Diastolic Function by Tissue Doppler Imaging Predicts Mortality in Patients with Atrial Fibrillation

    DEFF Research Database (Denmark)

    Dons, Maria; BieringSørensen, Tor; Jensen, Jan Skov

    2015-01-01

    AIM: Tissue Doppler Imaging (TDI) detects early signs of left ventricular dysfunction. The prognostic potential of TDI in patients with atrial fibrillation (AF) has, however, not yet been clarified. This study evaluates the prognostic value of TDI in patients with atrial fibrillation. METHODS...

  19. Total average diastolic longitudinal displacement by colour tissue doppler imaging as an assessment of diastolic function

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Biering-Sørensen, Tor; Søgaard, Peter

    2016-01-01

    BACKGROUND: The current method for a non-invasive assessment of diastolic dysfunction is complex with the use of algorithms of many different echocardiographic parameters. Total average diastolic longitudinal displacement (LD), determined by colour tissue Doppler imaging (TDI) via the measurement...

  20. Challenges in noise removal from Doppler spectra acquired by a continuous-wave lidar

    DEFF Research Database (Denmark)

    Angelou, Nikolas; Foroughi Abari, Farzad; Mann, Jakob

    2012-01-01

    are presented. A method for determining the background noise spectrum without interrupting the transmission of the laser beam is described. Moreover, the dependency between the determination of the threshold of a Doppler spectrum with low signal-to-noise ratios and the characteristics of the wind flow......This paper is focused on the required post processing of Doppler spectra, acquired from a continuous-wave coherent lidar at high sampling rates (400 Hz) and under rapid scanning of the laser beam. In particular, the necessary steps followed for extracting the wind speed from such Doppler spectra...... are investigated and a systematic approach for removing the noise is outlined. The suggested post processing procedures are applied to two sample time series acquired by a short-range WindScanner during one second each....

  1. Tissue Doppler Imaging in the evaluation of abdominal aortic pulsatility: a useful tool for the neonatologist.

    Science.gov (United States)

    Valerio, Enrico; Grison, Alessandra; Capretta, Anna; Golin, Rosanna; Ferrarese, Paola; Bellettato, Massimo

    2017-03-01

    Sonographic cardiac evaluation of newborns with suspected aortic coarctation (AoC) should tend to demonstrate a good phasic and pulsatile flow and the absence of pressure gradient along a normally conformed aortic arch from the modified left parasternal and suprasternal echocardiographic views; these findings, however, may not necessarily rule out a more distal coarctation in the descending aorta. For this reason, the sonographic exam of newborns with suspected AoC should always include a Doppler evaluation of abdominal aortic blood flow from the subcostal view. Occasionally, however, a clearly pulsatile Doppler flow trace in abdominal aorta may be difficult to obtain due to the bad insonation angle existing between the probe and the vessel. In such suboptimal ultrasonic alignment situation, the use of Tissue Doppler Imaging instead of classic Doppler flow imaging may reveal a preserved aortic pulsatility by sampling the aortic wall motion induced by normal flow. We propose to take advantage of the TDI pattern as a surrogate of a normal pulsatile Doppler flow trace in abdominal aorta when the latter is difficult to obtain due to malalignment with the insonated vessel.

  2. Time series analysis of continuous-wave coherent Doppler Lidar wind measurements

    International Nuclear Information System (INIS)

    Sjoeholm, M; Mikkelsen, T; Mann, J; Enevoldsen, K; Courtney, M

    2008-01-01

    The influence of spatial volume averaging of a focused 1.55 μm continuous-wave coherent Doppler Lidar on observed wind turbulence measured in the atmospheric surface layer over homogeneous terrain is described and analysed. Comparison of Lidar-measured turbulent spectra with spectra simultaneously obtained from a mast-mounted sonic anemometer at 78 meters height at the test station for large wind turbines at Hoevsoere in Western Jutland, Denmark is presented for the first time

  3. Evaluation of Cardiovascular System in Fibromyalgia Syndrome: Tissue Doppler Echocardiographic Investigation

    Directory of Open Access Journals (Sweden)

    Selma YAZICI

    2010-05-01

    Full Text Available Aim: We aim to investigate besides the cardiac structures and functions by both conventionalmethods and Tissue Doppler Echocardiography (TDE which is a new and useful method inpatients with Fibromyalgia (FM. Additionally, we evaluated QT parameters (QT maximum,QT minimum and QT dispertion with the use of electrocardiography in order to measure theautonomic dysfunction which is a possible mechanism in the pathogenesis of the disease. Methods: The study was performed on 42 patients (mean age 41 years, 38 female and 38completely healthy subjects (35 female, mean age of 42 years who were admitted to the sameclinic were collected as the control group. All the individuals were undergone a completephysical examination, electrocardiography (recordings were displayed at 50 mm/s speed andechocardiography evaluation (both conventional methods and TDE.Results: Analysis of electrocardiographic recordings revealed mildly increased mean QTdispertion in the patient group, but this difference was statistically insignificant. Analysis ofconventional echocardiographic parameters revealed similar results between the patient groupand the control cases. However, an important finding of this study is that significant diastolicdysfunction was found in the patient group which was recorded with the TDE technique. Emwave velocity and Em/Am ratios were significantly lower in patients with FM compared withcontrols (p<0.005, p<0.01, respectively. Sm and Am waves velocities were similar in bothgroups. Conclusion: In this study, significant left ventricular diastolic dysfunction which was detectedby TDE technique can partly explain several symptoms such as fatigue and dyspnea in FM. Inaddition, fully cardiac evaluation of patients with FM might be obtained supporting findingsthe autonomic dysfunction theory in fibromyalgia pathogenesis.

  4. Detection of Early Right Ventricular Dysfunction in Young Patients With Thalassemia Major Using Tissue Doppler Imaging

    Science.gov (United States)

    Bornaun, Helen; Dedeoglu, Reyhan; Oztarhan, Kazim; Dedeoglu, Savas; Erfidan, Erkan; Gundogdu, Muge; Aydogan, Gonul; Cengiz, Dicle

    2016-01-01

    Background Myocardial iron overload is the most common cause of mortality in patients with thalassemia major (TM), also known as beta-thalassemia. T2* cardiovascular magnetic resonance imaging (MRI) is the best way of monitoring cardiac iron, and new echocardiographic techniques can be used to assess cardiac function. Objectives The aim of this study was to assess the systolic and diastolic right ventricular (RV) function of patients with TM using tissue Doppler imaging (TDI) and to determine whether this echocardiographic technique is an adequate diagnostic tool for the screening and detection of subclinical cardiac dysfunction. Patients and Methods Eighty-four patients with TM were evaluated by conventional echocardiography and pulse-wave TDI. The data of the TM group (Group 1) were compared with that of 85 age- and sex-matched healthy controls (Group 2). Cardiovascular T2* MRI examinations were performed in 49 of the 85 patients. Results The patients with TM had significantly lower values for weight, height, body mass index, systolic arterial pressure, deceleration time, E’/A’, and ejection time (ET) than the controls. Group 1 also had significantly higher values for peak early diastolic velocity (E) over peak late diastolic velocity (A), peak early diastolic velocity of TDI (E’), peak late diastolic velocity of TDI (A’), E/E’, isovolumetric relaxation time, isovolumetric contraction time, and RV magnetic perfusion imaging (MPI) than Group 2. Conclusions RV diastolic dysfunction occurs before systolic deterioration in patients with TM and cannot be screened with conventional echocardiographic techniques. In routine practice, TDI measurements, MPI (for global function) and the E/E’ parameter (for diastolic function) can be used to screen and detect early RV dysfunction. PMID:27617076

  5. Cardiac Time Intervals Measured by Tissue Doppler Imaging M-mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Schnohr, Peter

    2016-01-01

    function was evaluated in 1915 participants by using both conventional echocardiography and tissue Doppler imaging (TDI). The cardiac time intervals, including the isovolumic relaxation time (IVRT), isovolumic contraction time (IVCT), and ejection time (ET), were obtained by TDI M-mode through the mitral......). Additionally, they displayed a significant dose-response relationship, between increasing severity of elevated blood pressure and increasing left ventricular mass index (P

  6. Evaluation of Pulsed Doppler-Versus Tissue Doppler-Derived Tei Index of Right and Left Ventricle in Fetuses

    Directory of Open Access Journals (Sweden)

    Hamid Amoozgar

    2011-12-01

    Full Text Available Background: The myocardial performance index (MPI, also known as the Tei index, was introduced by Tei et al. to evaluate cardiac function in adults with dilated cardiomyopathy. This index is defined as the sum of isovolumic contraction time (ICT and isovolumic relaxation time (IRT, divided by ejection time (ET. Objectives: To determine the correlation between pulsed Doppler (PD- and tissue Doppler imaging (TDI-derived Tei indices in fetuses. Patients and Methods: Right and left ventricle PD and TDI echocardiographic data were obtained from 59 fetuses (11 pregnant women who were positive for anti-SSA-Ro or anti-SSB-La antibodies, 18 women who were referred due to dysrhythmia, and 30 women who had normal clinical findings. Results: Mean fetal gestational age was 27 ± 6.4 weeks. Mean PD Tei index of the mitral and tricuspid valve was 0.58 ± 0.05 and 0.53 ± 0.08, respectively. Mean TDI indices for the mitral and tricuspid valve were 0.56 ± 0.09 and 0.55 ± 0.08, respectively. There were no significant differences between mitral and tricuspid PD- and TDI-derived Tei indices (P = 0.87, P= 0.21, but the Bland-Altman diagrams showed no fine agreement between the indices (the mean difference ± 1 standard deviation of the right ventricular PD- and TDI-derived Tei indices was 0.24 ± 0.02 and 0.29 ± 0.04 for the left ventricle. There were no significant differences in PD- and TDI-derived Tei indexes between groups of evaluated fetuses (Mitral valve: PD-Tei P=0.69, TDI-Tei P=0.49; Tricuspid valve: PD-Tei P=0.41, TDI-Tei P=0.36. Conclusions: Although the mean values of the two indices did not differ significantly, the TDI-derived and PD-derived Tei indices did not have fine agreement.

  7. Myocardial response to a triathlon in male athletes evaluated by Doppler tissue imaging and biochemical parameters

    DEFF Research Database (Denmark)

    Leetmaa, T H; Dam, A; Glintborg, D

    2008-01-01

    (cTnT) and pro-brain natriuretic peptide (pro-BNP)] and echocardiography. Conventional echocardiography techniques and new Doppler tissue imaging (DTI) modalities were applied before and immediately after the competition. Blood samples were drawn 1 week before, immediately after and 12-24 h post...... and systolic velocities decreased, thus suggesting reversible cardiac fatigue. When using cardiac markers and echocardiographic findings, a triathlon was found to have no significant negative effects on left ventricular function or myocardial tissue in male athletes....

  8. HF doppler sounder measurements of the ionospheric signatures of small scale ULF waves

    Directory of Open Access Journals (Sweden)

    L. J. Baddeley

    2005-07-01

    Full Text Available An HF Doppler sounder, DOPE (DOppler Pulsation Experiment with three azimuthally-separated propagation paths is used to provide the first statistical examination of small scale-sized, high m waves where a direct measurement of the azimuthal wavenumber m, is made in the ionosphere. The study presents 27 events, predominantly in the post-noon sector. The majority of events are Pc4 waves with azimuthal m numbers ranging from –100 to –200, representing some of the smallest scale waves ever observed in the ionosphere. 4 Pc5 waves are observed in the post-noon sector. The fact that measurements for the wave azimuthal m number and the wave angular frequency are available allows the drift-bounce resonance condition to be used to hypothesise potential particle populations which could drive the waves through either a drift or drift-bounce resonance interaction mechanism. These results are compared with the statistical study presented by Baddeley et al. (2004 which investigated the statistical likelihood of such driving particle populations occurring in the magnetospheric ring current. The combination of these two studies indicates that any wave which requires a possible drift resonance interaction with particles of energies >60 keV, is statistically unlikely to be generated by such a mechanism. The evidence presented in this paper therefore suggests that in the pre-noon sector the drift-bounce resonance mechanism is statistically more likely implying an anti-symmetric standing wave structure while in the post-noon sector both a drift or drift-bounce resonance interaction is statistically possible, indicating both symmetric and anti-symmetric standing mode structures. A case study is also presented investigating simultaneous observations of a ULF wave in ground magnetometer and DOPE data. The event is in the lower m range of the statistical study and displays giant pulsation (Pg characteristics.

    Keywords

  9. HF doppler sounder measurements of the ionospheric signatures of small scale ULF waves

    Directory of Open Access Journals (Sweden)

    L. J. Baddeley

    2005-07-01

    Full Text Available An HF Doppler sounder, DOPE (DOppler Pulsation Experiment with three azimuthally-separated propagation paths is used to provide the first statistical examination of small scale-sized, high m waves where a direct measurement of the azimuthal wavenumber m, is made in the ionosphere. The study presents 27 events, predominantly in the post-noon sector. The majority of events are Pc4 waves with azimuthal m numbers ranging from –100 to –200, representing some of the smallest scale waves ever observed in the ionosphere. 4 Pc5 waves are observed in the post-noon sector. The fact that measurements for the wave azimuthal m number and the wave angular frequency are available allows the drift-bounce resonance condition to be used to hypothesise potential particle populations which could drive the waves through either a drift or drift-bounce resonance interaction mechanism. These results are compared with the statistical study presented by Baddeley et al. (2004 which investigated the statistical likelihood of such driving particle populations occurring in the magnetospheric ring current. The combination of these two studies indicates that any wave which requires a possible drift resonance interaction with particles of energies >60 keV, is statistically unlikely to be generated by such a mechanism. The evidence presented in this paper therefore suggests that in the pre-noon sector the drift-bounce resonance mechanism is statistically more likely implying an anti-symmetric standing wave structure while in the post-noon sector both a drift or drift-bounce resonance interaction is statistically possible, indicating both symmetric and anti-symmetric standing mode structures. A case study is also presented investigating simultaneous observations of a ULF wave in ground magnetometer and DOPE data. The event is in the lower m range of the statistical study and displays giant pulsation (Pg characteristics. Keywords. Ionosphere (Ionosphere

  10. Usefulness of hemodynamically distribution of intranodal vessels in differentiating metastatic neck lymph nodes-value of color doppler and spectral wave sonogram

    International Nuclear Information System (INIS)

    Mumtaz, U.

    2017-01-01

    Objective: To evaluate the diagnostic assessment of enlarged lymph nodes, based on its perfusion pattern by taking tissue diagnosis as gold standard. Study Design: Analytical study. Place and Duration of Study: Departments of Radiology and Pathology, PIMS Hospital, Islamabad, from February to May 2016. Methodology: Color sonography of patients with clinically, palpable cervical lymph nodes were carried by senior trainee under the supervision of senior radiologist. Ultrasound guided tissue diagnosis was obtained in all suspected malignant cases. Histopathology was taken as the gold standard for determining accuracy. Results: Accuracy, sensitivity and specificity, positive and negative predictive values of color Doppler ultrasound in detecting malignant cervical lymphadenopathy was found to be 88.46%, 86.05%, 79.31% and 92.50%, respectively with diagnostic accuracy of 86.95%, when intranodal vascular pattern on color Doppler imaging was analyzed. Using spectral wave indexes, the same values were 92.31%, 90.70%, 85.71%, 95.12%, respectively with overall diagnostic accuracy of 91.30%. Conclusion: Color Doppler sonography is much sensitive borderline than grey scale findings alone. Furthermore, lymph nodes appearing in the detection of malignant nodes on grey scale images can be reliably diagnosed on Doppler scan. (author)

  11. Flow angle dependent photoacoustic Doppler power spectra under intensity-modulated continuous wave laser excitation

    Directory of Open Access Journals (Sweden)

    Yu Tong

    2016-02-01

    Full Text Available Photoacoustic Doppler (PAD power spectra showing an evident Doppler shift represent the major characteristics of the continuous wave-excited or burst wave-excited versions of PAD flow measurements. In this paper, the flow angle dependences of the PAD power spectra are investigated using an experiment setup that was established based on intensity-modulated continuous wave laser excitation. The setup has an overall configuration that is similar to a previously reported configuration, but is more sophisticated in that it accurately aligns the laser illumination with the ultrasound detection process, and in that it picks up the correct sample position. In the analysis of the power spectra data, we find that the background power spectra can be extracted by combining the output signals from the two channels of the lock-in amplifier, which is very useful for identification of the PAD power spectra. The power spectra are presented and analyzed in opposite flow directions, at different flow speeds, and at different flow angles. The power spectra at a 90° flow angle show the unique properties of symmetrical shapes due to PAD broadening. For the other flow angles, the smoothed power spectra clearly show a flow angle cosine relationship.

  12. Observation of fast-ion Doppler-shifted cyclotron resonance with shear Alfven waves

    International Nuclear Information System (INIS)

    Zhang Yang; Heidbrink, W. W.; Boehmer, H.; McWilliams, R.; Vincena, S.; Carter, T. A.; Gekelman, W.; Leneman, D.; Pribyl, P.

    2008-01-01

    The Doppler-shifted cyclotron resonance (ω-k z v z =Ω f ) between fast ions and shear Alfven waves is experimentally investigated (ω, wave frequency; k z , axial wavenumber; v z , fast-ion axial speed; Ω f , fast-ion cyclotron frequency). A test particle beam of fast ions is launched by a Li + source in the helium plasma of the LArge Plasma Device (LAPD) [W. Gekelman, H. Pfister, Z. Lucky, J. Bamber, D. Leneman, and J. Maggs, Rev. Sci. Instrum. 62, 2875 (1991)], with shear Alfven waves (SAW) (amplitude δ B/B up to 1%) launched by a loop antenna. A collimated fast-ion energy analyzer measures the nonclassical spreading of the beam, which is proportional to the resonance with the wave. A resonance spectrum is observed by launching SAWs at 0.3-0.8ω ci . Both the magnitude and frequency dependence of the beam-spreading are in agreement with the theoretical prediction using a Monte Carlo Lorentz code that launches fast ions with an initial spread in real/velocity space and random phases relative to the wave. Measured wave magnetic field data are used in the simulation.

  13. (abstract) Spacecraft Doppler Tracking with the Deep Space Network in the Search for Gravitational Waves

    Science.gov (United States)

    Asmar, Sami; Renzetti, Nicholas

    1994-01-01

    The Deep Space Network generates accurate radio science data observables for investigators who use radio links between spacecraft and the Earth to examine small changes in the phase and/or amplitude of the signal to study a wide variety of structures and phenomena in space. Several such studies are directed at aspects of the theory of general relativity such as gravitational redshift and gravitational waves. A gravitational wave is a propagating, polarized gravitational field, a ripple in the curvature of space-time. In Einstein's theory of general relativity, the waves are propagating solutions of the Einstein field equations. Their amplitudes are dimensionless strain amplitudes that change the fractional difference in distance between test masses and the rates at which separated clocks keep time. Predicted by all relativistic theories of gravity, they are extremely weak (the ratio of gravitational forces to electrical forces is about 10(sup -40)) and are generated at detectable levels only by astrophysical sources - very massive sources under violent dynamical conditions. The waves have never been detected but searches in the low-frequency band using Doppler tracking of many spacecraft have been conducted and others are being planned. Upper limits have been placed on the gravitational wave strength with the best sensitivities to date are for periodic waves being 7 x 10(sup -15).

  14. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    2016-01-01

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  15. Exercise and Cardiac Function by Tissue Doppler Imaging. The Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Joseph, Gowsini; Sogaard, Peter; Nielsen, Gitte

    diastolic (e') and late diastolic (a') velocities were measured by color TDI. Longitudinal displacement (LD) was calculated from the velocity curve during ejection. Statistical tests were performed by linear univariate and multivariable regression analyses, in relation to age groups (lt;50years, 50-65 years......Introduction: TDI (Tissue Doppler Imaging) is a sensitive marker of myocardial dysfunction and mortality in heart disease and in the general population. Regular physical activity is associated with risk reduction in coronary heart disease and mortality. There is a need for studies to clarify...

  16. Cardiac time intervals by tissue Doppler imaging M-mode echocardiography

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor

    2016-01-01

    for myocardial myocytes to achieve an LV pressure equal to that of aorta increases, resulting in a prolongation of the isovolumic contraction time (IVCT). Furthermore, the ability of myocardial myocytes to maintain the LV pressure decreases, resulting in reduction in the ejection time (ET). As LV diastolic...... of whether the LV is suffering from impaired systolic or diastolic function. A novel method of evaluating the cardiac time intervals has recently evolved. Using tissue Doppler imaging (TDI) M-mode through the mitral valve (MV) to estimate the cardiac time intervals may be an improved method reflecting global...

  17. Tissue Doppler echocardiography improves the diagnosis of coronary artery stenosis in stable angina pectoris

    DEFF Research Database (Denmark)

    Hoffmann, Soren; Jensen, Jan Skov; Iversen, Allan Zeeberg

    2012-01-01

    Aim To determine if colour tissue Doppler imaging (TDI) performed at rest in patients with suspected stable angina pectoris (SAP) is able to predict the presence of significant coronary artery disease (CAD). METHODS AND RESULTS: This study comprises 296 consecutive patients with clinically...... by colour TDI at six mitral annular sites and averaged to provide global estimates. Duke score (DS), including ST depression, chest pain, and exercise capacity, was used as the outcome of the exercise ECG. Patients with an area stenosis of ≥70% in at least one epicardial coronary artery were categorized...

  18. Absorption and scattering coefficient dependence of laser-Doppler flowmetry models for large tissue volumes

    International Nuclear Information System (INIS)

    Binzoni, T; Leung, T S; Ruefenacht, D; Delpy, D T

    2006-01-01

    Based on quasi-elastic scattering theory (and random walk on a lattice approach), a model of laser-Doppler flowmetry (LDF) has been derived which can be applied to measurements in large tissue volumes (e.g. when the interoptode distance is >30 mm). The model holds for a semi-infinite medium and takes into account the transport-corrected scattering coefficient and the absorption coefficient of the tissue, and the scattering coefficient of the red blood cells. The model holds for anisotropic scattering and for multiple scattering of the photons by the moving scatterers of finite size. In particular, it has also been possible to take into account the simultaneous presence of both Brownian and pure translational movements. An analytical and simplified version of the model has also been derived and its validity investigated, for the case of measurements in human skeletal muscle tissue. It is shown that at large optode spacing it is possible to use the simplified model, taking into account only a 'mean' light pathlength, to predict the blood flow related parameters. It is also demonstrated that the 'classical' blood volume parameter, derived from LDF instruments, may not represent the actual blood volume variations when the investigated tissue volume is large. The simplified model does not need knowledge of the tissue optical parameters and thus should allow the development of very simple and cost-effective LDF hardware

  19. Acceleration rate of mitral inflow E wave: a novel transmitral doppler index for assessing diastolic function.

    Science.gov (United States)

    Badkoubeh, Roya Sattarzadeh; Tavoosi, Anahita; Jabbari, Mostafa; Parsa, Amir Farhang Zand; Geraeli, Babak; Saadat, Mohammad; Larti, Farnoosh; Meysamie, Ali Pasha; Salehi, Mehrdad

    2016-06-10

    We performed comprehensive transmitral and pulmonary venous Doppler echocardiographic studies to devise a novel index of diastolic function. This is the first study to assess the utility of the acceleration rate (AR) of the E wave of mitral inflow as a primary diagnostic modality for assessing diastolic function. Study group consisted of 84 patients (53 + 11 years) with left ventricle (LV) diastolic dysfunction and 34 healthy people (35 ± 9 years) as control group, who were referred for clinically indicated two-dimensional transthoracic echocardiogram (TTE) during 2012 and 2013 to Imam Hospital. Normal controls were defined as patients without clinical evidence of cardiac disease and had normal TTE. LV diastolic function was determined according to standardized protocol of American Society of Echocardiography (ASE). As our new parameter, AR of E wave of mitral inflow was also measured in all patients. It was represented by the slope of the line between onset of E wave and peak of it. Correlation between AR of E wave and LV diastolic function grade was measured using the Spearman correlation coefficient. Receiver operating characteristic (ROC) curve was used to determine the sensitivity and specificity of AR of E wave in diagnosing LV diastolic dysfunction in randomly selected two-thirds of population then its derived cutoff was evaluated in rest of the population. The institutional review board of the hospital approved the study protocol. All participants gave written informed consent. This investigation was in accordance with the Declaration of Helsinki. The mean value of AR was 1010 ± 420 cm/s(2) in patients whereas the mean value for the normal controls was 701 ± 210 cm/s(2). There was a strong and graded relation between AR of E wave of mitral inflow and LV diastolic function grade (Spearman P ≤0.0001, rs =0.69). ROC curve analysis revealed that AR of E wave of mitral inflow =750 cm/s(2) predicted moderate or severe LV diastolic

  20. On the influence of ocean waves on simulated GNSS-R delay-doppler maps

    Science.gov (United States)

    Clarizia, M. P.; di Bisceglie, M.; Galdi, C.; Gommenginger, C.; Srokosz, M.

    2012-04-01

    Global Navigation Satellite System-Reflectometry (GNSS-R), is an established technique that exploits GNSS signals of opportunity reflected from the surface of the ocean, to look primarily at the ocean surface roughness. The strength of this technique, and the primary motivation to carry it forward, is in the fact that GNSS signals are available globally, all the time and over the long term, and could help dramatically improve the monitoring of ocean wind and waves. GNSS-R offers the prospect of high density global measurements of directional sea surface roughness, which are essential for scientific purposes (i.e. quantifying the air-sea exchanges of gases), operational weather and ocean forecasting (i.e. prediction of high winds, dangerous sea states, risk of flooding and storm surges) and to support important climate-relevant Earth Observation techniques (IR SST, or surface salinity retrieval). The retrieval of ocean roughness from GNSS-R data has now been demonstrated with a reasonable level of accuracy from both airborne [1] and spaceborne [2] platforms. In both cases, Directional Mean Square Slopes (DMSS) of the ocean surface have been retrieved from GNSS-R data, in the form of Delay-Doppler Maps (DDMs), using an established theoretical scattering model by Zavorotny and Voronovich (Z-V) [3]. The need for a better assessment of the way the ocean waves influence the scattering of GPS signals has recently led to a different approach, consisting of simulating the scattering of such signals, using a more sophisticated large-scale scattering model than Z-V, and explicit simulations of realistic seas. Initial results produced from these simulations have been recently published in [4], where the emphasis has been put on the effects of different sea states on Radar Cross Section (RCS) and Polarization Ratio (PR) in space domain. Linear wind wave surfaces have been simulated using the Elfouhaily wind wave spectrum [5], for different wind speeds and directions, and with

  1. Validation of color Doppler sonography for evaluating relative displacement between the flexor tendon and subsynovial connective tissue.

    Science.gov (United States)

    Tat, Jimmy; Kociolek, Aaron M; Keir, Peter J

    2015-04-01

    A common pathologic finding in carpal tunnel syndrome is fibrosis and thickening of the subsynovial connective tissue. This finding suggests an etiology of excessive shear forces, with relative longitudinal displacement between the flexor tendon and adjacent subsynovial connective tissue. The purpose of this study was to validate color Doppler sonography for measurement of tendon displacement over time. Eight unmatched fresh frozen cadaver arms were used to evaluate color Doppler sonography for measurement of tendon displacement. The middle flexor digitorum superficialis tendon was moved through a physiologic excursion of 20 mm at 3 different tendon velocities (50, 100, and 150 mm/s). We found that color Doppler sonography provided accurate measurement of tendon displacement, with absolute errors of -0.05 mm (50 mm/s), -1.24 mm (100 mm/s), and -2.36 mm (150 mm/s) on average throughout the tendon excursion range. Evaluating relative displacement between the tendon and subsynovial connective tissue during finger flexion-extension movements also offered insight into the gliding mechanism of the subsynovial connective tissue. During flexion, we observed a curvilinear increase in relative displacement, with greater differential motion at the end range of displacement, likely due to the sequential stretch of the fibrils between successive layers of the subsynovial connective tissue. In extension, there was a linear return in relative displacement, suggesting a different unloading mechanism characterized by uniform relaxation of fibrils. We demonstrated the validity of color Doppler displacement for use in the evaluation of relative motion. Color Doppler sonography is useful in our understanding of the behavior of the subsynovial connective tissue during tendon excursion, which may elucidate the role of finger motion in the etiology of shear injury. © 2015 by the American Institute of Ultrasound in Medicine.

  2. Clinical significance of a presystolic wave on Doppler examination of the left ventricular outflow tract.

    Science.gov (United States)

    Joshi, Kamal R; Kabirdas, Deepa; Romero-Corral, Abel; Shah, Mahek; Figueredo, Vincent M; Pressman, Gregg S

    2014-11-15

    A presystolic wave (PSW) is commonly seen on Doppler examination of the left ventricular outflow tract (LVOT), but is little studied. We conducted a retrospective study to assess the prevalence of the PSW, correlations with various Doppler parameters, and its clinical significance. Two hundred echocardiograms, 100 with ejection fraction (EF) >55% and 100 with EF <45%, were reviewed. Mitral inflow velocities, septal annular velocities, LVOT, and PSW velocities were measured. Major adverse cardiovascular events (MACE [death, heart failure hospitalization, atrial fibrillation, and stroke]) were compared between those with and without a PSW, in both EF groups. Mean age was 58 ± 15 years; 56% were men and 69% were African-American. PSW prevalence was similar between normal (68%) and reduced EF groups (62%). However, its velocity was less in the low EF group (37 ± 10 vs 48 ± 16 cm/s, p <0.0001). In subjects with normal EF PSW velocity correlated with mitral A velocity (rho = 0.43, p = 0.0003). In subjects with reduced EF the association with A velocity was not significant (rho = 0.22, p = 0.09), but there was a significant association with annular a' velocity (rho = 0.38, p = 0.002). Over a mean follow-up of 1.7 ± 0.3 years, 57 subjects (28%) experienced MACE. Those without a PSW had more MACE (39% vs 23%, p = 0.02); PSW absence remained predictive of MACE after adjustment for multiple variables, especially in patients with reduced EF. In conclusion, PSW is common in the LVOT. Its presence and magnitude are associated with measures of atrial contraction. Its absence is associated with increased rates of adverse events, especially in patients with low EF. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Tissue Doppler echocardiography reveals distinct patterns of impaired myocardial velocities in different degrees of coronary artery disease

    DEFF Research Database (Denmark)

    Hoffmann, Soren; Mogelvang, Rasmus; Olsen, Niels Thue

    2010-01-01

    Aim To determine how the left ventricular wall motion assessed by echocardiographic Tissue Doppler Imaging (TDI) is affected by increasing severity of coronary artery disease (CAD) among patients with stable angina pectoris and preserved ejection fraction. METHODS AND RESULTS: This study comprise...

  4. Measurement of subcutaneous adipose tissue blood flow in the morbidly obese using a laser Doppler velocimeter

    Science.gov (United States)

    Klassen, Gerald A.; Paton, Barry E.; Maksym, Geoff; Janigan, David; Perey, Bernard

    1992-08-01

    Using a laser Doppler velocimeter (LDV) subcutaneous adipose tissue blood flow (AF) was recorded in the upright and supine positions in the upper and lower abdomen in 22 morbidly obese patients before gastroplasty. Age was 42 +/- 3 (mean +/- SEM), weight 135 +/- 7 kg, and body mass index (BMI) 51 +/- 3. Adipose flow expressed as mV was: supine, upper abdomen 647 +/- 23, lower abdomen 604 +/- 24; upright, upper abdomen 621 +/- 27, lower abdomen 607 +/- 29. AF was significantly more in the upper than lower abdomen (supine position) and AF was significantly lower in the lower abdomen upright than the upper abdomen supine. Regression analysis of age indicates that blood flow decreases in the lower abdomen so that in the supine position the difference between upper and lower abdomen AF increases. Similar analysis of BMI did not indicate significant trends. These data indicate that with morbid obesity there is lower tissue blood flow to the lower abdomen. This may explain why such patients may develop areas of painful ischemic necrosis in the dependent region of their anterior abdominal pannus.

  5. New sub-Doppler absorption resonances in a thin gas cell produced by means of a running monochromatic wave

    International Nuclear Information System (INIS)

    Tajalli, H; Ahmadi, S; Izmailov, A Ch

    2002-01-01

    A theoretical investigation is carried out through the interaction of the plane running monochromatic light wave, having an arbitrary intensity, with atoms (molecules) of a rarefied gas in the plane cell (at the normal incidence of the wave). Cases of closed and open resonance transitions from the non-degenerate ground (or metastable) quantum level are considered. Possible sub-Doppler resonances are analysed in the wave absorption, caused by the transient establishment of the optical coherence on the transition, Rabi oscillations between its levels, and optical pumping during the free flights of particles between the walls of the cell. Results of the previous works on given problems are generalized, which were obtained at definite restrictions on the wave intensity and cell length. Moreover, non-trivial sub-Doppler spectral structures, resulting as a consequence of the dependence of the absorption saturation on the transit relaxation of particles, have been established and investigated. Such structures may consist of a number of peaks and dips caused by Rabi oscillations between the transition levels. The results obtained can be used in sub-Doppler spectroscopy and for the stabilization of laser frequencies in thin gas cells

  6. Study of the Myocardial Contraction and Relaxation Velocities through Doppler Tissue Imaging Echocardiography: A New Alternative in the Assessment of the Segmental Ventricular Function

    Directory of Open Access Journals (Sweden)

    Silva Carlos Eduardo Suaide

    2002-01-01

    Full Text Available OBJECTIVE: Doppler tissue imaging (DTI enables the study of the velocity of contraction and relaxation of myocardial segments. We established standards for the peak velocity of the different myocardial segments of the left ventricle in systole and diastole, and correlated them with the electrocardiogram. METHODS: We studied 35 healthy individuals (27 were male with ages ranging from 12 to 59 years (32.9 ± 10.6. Systolic and diastolic peak velocities were assessed by Doppler tissue imaging in 12 segments of the left ventricle, establishing their mean values and the temporal correlation with the cardiac cycle. RESULTS: The means (and standard deviation of the peak velocities in the basal, medial, and apical regions (of the septal, anterior, lateral, and posterior left ventricle walls were respectively, in cm/s, 7.35(1.64, 5.26(1.88, and 3.33(1.58 in systole and 10.56(2.34, 7.92(2.37, and 3.98(1.64 in diastole. The mean time in which systolic peak velocity was recorded was 131.59ms (±19.12ms, and diastolic was 459.18ms (±18.13ms based on the peak of the R wave of the electrocardiogram. CONCLUSION: In healthy individuals, maximum left ventricle segment velocities decreased from the bases to the ventricular apex, with certain proportionality between contraction and relaxation (P<0.05. The use of Doppler tissue imaging may be very helpful in detecting early alterations in ventricular contraction and relaxation.

  7. Doppler limited rotational transitions of OH and SH radicals measured by continuous-wave terahertz photomixing

    Science.gov (United States)

    Eliet, Sophie; Martin-Drumel, Marie-Aline; Guinet, Mickaël; Hindle, Francis; Mouret, Gaël; Bocquet, Robin; Cuisset, Arnaud

    2011-12-01

    A continuous-wave terahertz (CW-THz) source generated by photomixing has been employed to detect and quantify radicals produced in a cold plasma probing their spin-rotation transitions. Due to their dual interest for both atmospherists and astrophysicists, the hydroxyl OH and the mercapto SH radicals have been chosen. The photomixing technique which can access the largest range of THz frequencies of any known coherent source, allowed to resolve the Doppler-limited hyperfine transitions of OH in the 2.5 THz frequency region. Line profile analysis of the hyperfine components demonstrated that OH radicals have been detected in this region at a ppm level at a temperature close to 490 K. The hyperfine structure of SH has been resolved for the first time above 1 THz. Ten new frequency transitions have been measured in the 1.3-2.6 THz frequency range using the CW-THz synthesizer based on a frequency comb. With relative uncertainties better than 10 -7, the CW-THz frequencies measured in this study are now competitive with those measured by other instruments such as frequency multiplication chains or FT-FIR spectrometers and are now capable to improve the predictions of the complete high-resolution spectra of these radicals collected in the atmospheric and astrophysical spectroscopic databases. versioncorrigeeAC 2011-07-18 17:32 2011 Arnaud Cuisset.

  8. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    OpenAIRE

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in f...

  9. Time interval between maternal electrocardiogram and venous Doppler waves in normal pregnancy and preeclampsia: a pilot study.

    Science.gov (United States)

    Tomsin, K; Mesens, T; Molenberghs, G; Peeters, L; Gyselaers, W

    2012-12-01

    To evaluate the time interval between maternal electrocardiogram (ECG) and venous Doppler waves at different stages of uncomplicated pregnancy (UP) and in preeclampsia (PE). Cross-sectional pilot study in 40 uncomplicated singleton pregnancies, categorized in four groups of ten according to gestational age: 10 - 14 weeks (UP1), 18 - 23 weeks (UP2), 28 - 33 weeks (UP3) and ≥ 37 weeks (UP4) of gestation. A fifth group of ten women with PE was also included. A Doppler flow examination at the level of renal interlobar veins (RIV) and hepatic veins (HV) was performed according to a standard protocol, in association with a maternal ECG. The time interval between the ECG P-wave and the corresponding A-deflection of the venous Doppler waves was measured (PA), and expressed relative to the duration of the cardiac cycle (RR), and labeled PA/RR. In hepatic veins, the PA/RR is longer in UP 4 than in UP 1 (0.48 ± 0.15 versus 0.29 ± 0.09, p ≤ 0.001). When all UP groups were compared, the PA/RR increased gradually with gestational age. In PE, the HV PA/RR is shorter than in UP 3 (0.25 ± 0.09 versus 0.42 ± 0.14, p advanced gestational stages are consistent with known features of maternal cardiovascular adaptation. Shorter values in preeclampsia are consistent with maternal cardiovascular maladaptation mechanisms. Our pilot study invites more research of the relevance of the time interval between maternal ECG and venous Doppler waves as a new parameter for studying the gestational cardiovascular (patho)physiology of the maternal venous compartment by duplex sonography. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Material properties identification using ultrasonic waves and laser Doppler vibrometer measurements: a multi-input multi-output approach

    International Nuclear Information System (INIS)

    Longo, R; Vanlanduit, S; Guillaume, P

    2013-01-01

    In this paper a multi-input multi-output approach able to determine the material properties of homogeneous materials is presented. To do so, an experimental set-up which combines the use of multi harmonic signals with interleaved frequencies and laser Doppler vibrometer measurements has been developed. A modeling technique, based on transmission and reflection measurements, allowed the simultaneous determination of longitudinal wave velocity, density and thickness of the materials under test with high levels of precision and accuracy. (paper)

  11. The mechanism of mid-latitude Pi2 waves in the upper ionosphere as revealed by combined Doppler and magnetometer observations

    Directory of Open Access Journals (Sweden)

    V. A. Pilipenko

    2013-04-01

    Full Text Available The interpretation of simultaneous ionospheric Doppler sounding and ground magnetometer observations of low-latitude Pi2 waves is revised. We compare the theoretical estimates of the ionospheric Doppler velocity for the same amplitude of the ground magnetic disturbances produced by a large-scale compressional mode and an Alfvén mode. The plasma vertical displacement caused by the wave electric field is shown to be the dominating effect. Taking into account the correction of the previous paper, the observations of low-latitude Pi2 in the F layer ionosphere by Doppler sounding and SuperDARN (Super Dual Auroral Radar Network radars give consistent results. We suggest that the Doppler response to Pi2 waves is produced by the Alfvén wave component, but not the fast-mode component, whereas the ground magnetic signal is composed from both Alfvén and fast magnetosonic modes.

  12. Assessment of sustained effects of levosimendan and dobutamine on left ventricular systolic functions by using novel tissue Doppler derived indices in patients with advanced heart failure.

    Science.gov (United States)

    Oner, Ender; Erturk, Mehmet; Birant, Ali; Kurtar Mansıroglu, Aslı; Akturk, Ibrahim Faruk; Karakurt, Huseyin; Yalcin, Ahmet Arif; Uzun, Fatih; Somuncu, Mustafa Umut; Yildirim, Aydin

    2015-01-01

    Previous studies comparing levosimendan vs. dobutamine have revealed that levosimendan is better in relieving symptoms. Echocardiographic studies have been done using second measurements immediately following a dobutamine infusion or while it was still being administered. The aim of our study was assessment of sustained effects of 24 h levosimendan and dobutamine infusions on left ventricular systolic functions. A total of 61 patients with acutely decompensated heart failure with New York Heart Association (NYHA) class III or IV symptoms were randomized to receive either levosimendan or dobutamine 2:1 in an open label fashion. Before and 5 days after the initiation of infusions, functional class was assessed, N-terminal prohormone of B-type natriuretic peptide (NT-proBNP) levels and left ventricular ejection fraction (LVEF), mitral inflow peak E and A wave velocity, and E/A ratios were measured; using tissue Doppler imaging, isovolumic myocardial acceleration (IVA), peak myocardial velocity during isovolumic contraction (IVV), peak systolic velocity during ejection period (Sa), early (E') and late (A') diastolic velocities, and E'/A' and E/E' ratios were measured. The NYHA class improved in both groups, but improvements were prominent in the levosimendan group. NT-proBNP levels were significantly reduced in the levosimendan group. Improvements in LVEF and diastolic indices were significant in the levosimendan group. Tissue Doppler-derived systolic indices of IVV and IVA increased significantly in the levosimendan group. Improvements in left ventricular systolic and diastolic functions continue after a levosimendan infusion.

  13. Study on Tei index of right ventricular by tissue doppler imaging and the observation point selection

    International Nuclear Information System (INIS)

    Luo Yinli; Wu Ji; Guo Shenglan; Zhang Di; Li Zhixian

    2009-01-01

    Objective: To explore the right ventricular (RV) Tei index in patients with pulmonary hypertension (PH) by tissue Doppler imaging (TDI), and to explore more accurate observation point to obtain Tei index of right ventricular. Methods: Assessment of RV Tei index values was performed in 95 patients with PH and 32 normal subjects. The 95 patients were grouped into 3 groups according to the severity of PH. Tei index values were obtained by TDI measurement from three observation points, the anterior tricuspid and septal tricuspid attachment points in the apical 4-chamber view and the posterior tricuspid attachment point in parasternal right heart 2-chamber review. Results: (1) RV Tel index values were measured at the three points of PH was higher than the normal significantly (P<0.05). (2) RV Tei index values of the three PH groups at he anterior tricuspid attachment had significant difference each other (P<0.05). RV Tei index values of low-grade and medium-grade PH groups at septal tricuspid and posterior tricuspid had no significant difference, but that of high-grade PH group were higher than the low-grade and medium-grade PH group. Conclusion: RV Tei index value was significantly increased in PH patients. The Tei index value measured by TDI at anterior tricuspid attachment point in apical 4-chamber view was better than that at septal tricuspid attachment point in the apical 4-chamber view and posterior' attachment of parasternal right heart 2-chamber. (authors)

  14. Translational and Brownian motion in laser-Doppler flowmetry of large tissue volumes

    International Nuclear Information System (INIS)

    Binzoni, T; Leung, T S; Seghier, M L; Delpy, D T

    2004-01-01

    This study reports the derivation of a precise mathematical relationship existing between the different p-moments of the power spectrum of the photoelectric current, obtained from a laser-Doppler flowmeter (LDF), and the red blood cell speed. The main purpose is that both the Brownian (defining the 'biological zero') and the translational movements are taken into account, clarifying in this way what the exact contribution of each parameter is to the LDF derived signals. The derivation of the equations is based on the quasi-elastic scattering theory and holds for multiple scattering (i.e. measurements in large tissue volumes and/or very high red blood cell concentration). The paper also discusses why experimentally there exists a range in which the relationship between the first moment of the power spectrum and the average red blood cells speed may be considered as 'linear' and what are the physiological determinants that can result in nonlinearity. A correct way to subtract the biological zero from the LDF data is also proposed. The findings should help in the design of improved LDF instruments and in the interpretation of experimental data

  15. Acute Effects of Hemodialysis on Left and Right Ventricular Function: A Doppler Tissue Imaging Study

    Directory of Open Access Journals (Sweden)

    Tansel Erol

    2012-08-01

    Full Text Available Purpose: Doppler tissue imaging (DTI allows noninvasive assessment of both left ventricular (LV and right ventricular (RV function. The aim of this study was to evaluate the effect of hemodialysis (HD on LV and RV function using DTI. Method: Our study group included 30 patients on chronic HD program (mean age 45 15 years. Myocardial (Sm, Em, Am and annular velocities (Ea, Aa were measured in several cardiac territories before and after HD. Results: After HD, Ea significantly reduced from 10.8 3.4 cm/s to 9.6 2.4 cm/s (p = 0.029. Patients exhibited a lower Em following HD in all measured territories. Em/Am ratio was also reduced for each LV wall investigated after HD in all measured territories. At the RV segments, Sm, Em, and Am decreased significantly in all measured territories. Em of the anterior wall was positively related to ultrafiltration volume (r = 0.25, p = 0.006, whereas the decrease of Sm of RV basal segment correlated with a decrease of diastolic blood pressure (r = 0.23, p < 0.01. Conclusion: Our data indicate that a single HD session is associated with acute changes of systolic and diastolic parameters of LV and RV. [Cukurova Med J 2012; 37(4.000: 215-222

  16. Evaluation of regional wall motion abnormalities of the heart. Comparison with Doppler tissue echocardiography, MR-tagging and levocardiography

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Hamm, B.; Borges, A.C.; Walde, T.; Rutsch, W.; Baumann, G.

    2004-01-01

    Purpose: To compare the visual analysis of magnetic resonance imaging (MRI) with the tagging technique and Doppler tissue echocardiography with invasive ventriculography in detecting and quantifying regional left ventricular wall motion abnormalities. Materials and Methods: Sixteen patients with coronary artery disease and a history of prior myocardial infarction underwent invasive ventriculography. Doppler tissue echocardiography and MR-tagging within one week. Regional wall motion abnormalities (WMA) were detected in all patients. WMA were graded as normal=1; hypokinetic=2; akinetic=3; or dyskinetic=4. For agreement between MRI, echocardiography, and ventriculography the kappa coefficient (κ) according to Cohen was calculated. Results: The kappa coefficient (κ) was 0.962 for agreement between MRI and echocardiography and 0.602 for agreement between MRI and ventriculography as well as between echocardiography and ventriculography. Conclusion: Reliable analysis of regional left ventricular wall motion abnormalities is feasible using visual analysis of MR-tagging. MRI and Doppler tissue echocardiography detect more WMA than invasive ventriculography and grade them as more severe. (orig.)

  17. Doppler ultrasound for diagnosis of soft tissue sarcoma: efficacy of ultrasound-based screening score

    Directory of Open Access Journals (Sweden)

    Nagano Satoshi

    2015-06-01

    Full Text Available Background. The utility of ultrasound imaging in the screening of soft-part tumours (SPTs has been reported. We classified SPTs according to their blood flow pattern on Doppler ultrasound and re-evaluated the efficacy of this imaging modality as a screening method. Additionally, we combined Doppler ultrasound with several values to improve the diagnostic efficacy and to establish a new diagnostic tool.

  18. Tissue Doppler imaging of carotid plaque wall motion: a pilot study

    Directory of Open Access Journals (Sweden)

    Naylor A Ross

    2003-12-01

    Full Text Available Abstract Background Studies suggest the physical and mechanical properties of vessel walls and plaque may be of clinical value in the diagnosis and treatment of cardiovascular atherosclerotic disease. The purpose of this pilot study was to investigate the potential clinical application of ultrasound Tissue Doppler Imaging (TDI of Arterial Wall Motion (AWM and to quantify simple wall motion indices in normal and diseased carotid arteries. Methods 224 normal and diseased carotid arteries (0–100% stenoses were imaged in 126 patients (age 25–88 years, mean 68 ± 11. Longitudinal sections of the carotid bifurcation were imaged using a Philips HDI5000 scanner and L12-5 probe under optimized TDI settings. Temporal and spatial AWMs were analyzed to evaluate the vessel wall displacements and spatial gradients at peak systole averaged over 5 cardiac cycles. Results AWM data were successfully extracted in 91% of cases. Within the carotid bifurcation/plaque region, the maximum wall dilation at peak systole ranged from -100 to 750 microns, mean 335 ± 138 microns. Maximum wall dilation spatial gradients ranged 0–0.49, mean 0.14 ± 0.08. The AWM parameters showed a wide variation and had poor correlation with stenoses severity. Case studies illustrated a variety of pertinent qualitative and quantitative wall motion features related to the biophysics of arterial disease. Conclusion Our clinical experience, using a challenging but realistic imaging protocol, suggests the use of simple quantitative AWM measures may have limitations due to high variability. Despite this, pertinent features of AWM in normal and diseased arteries demonstrate the potential clinical benefit of the biomechanical information provided by TDI.

  19. Theoretical and experimental signal-to-noise ratio assessment in new direction sensing continuous-wave Doppler lidar

    DEFF Research Database (Denmark)

    Pedersen, Anders Tegtmeier; Foroughi Abari, Farzad; Mann, Jakob

    2014-01-01

    A new direction sensing continuous-wave Doppler lidar based on an image-reject homodyne receiver has recently been demonstrated at DTU Wind Energy, Technical University of Denmark. In this contribution we analyse the signal-to-noise ratio resulting from two different data processing methods both...... leading to the direction sensing capability. It is found that using the auto spectrum of the complex signal to determine the wind speed leads to a signal-to-noise ratio equivalent to that of a standard self-heterodyne receiver. Using the imaginary part of the cross spectrum to estimate the Doppler shift...... has the benefit of a zero-mean background spectrum, but comes at the expense of a decrease in the signal-to noise ratio by a factor of √2....

  20. Effects of chronic severe pulmonary regurgitation and percutaneous valve repair on right ventricular geometry and contractility assessed by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Iversen, Kasper K; Vejlstrup, Niels G

    2010-01-01

    Pulmonary regurgitation (PR) following repair of right ventricular (RV) outflow obstruction is related to slowly progressive RV dilatation and heart failure and will eventually require surgical intervention, but optimal timing of pulmonary valve replacement is challenging. Tissue Doppler based...

  1. Utility of Tissue Doppler Imaging in the Echocardiographic Evaluation of Left and Right Ventricular Function in Dogs with Myxomatous Mitral Valve Disease with or without Pulmonary Hypertension.

    Science.gov (United States)

    Baron Toaldo, M; Poser, H; Menciotti, G; Battaia, S; Contiero, B; Cipone, M; Diana, A; Mazzotta, E; Guglielmini, C

    2016-05-01

    In human medicine, right ventricular (RV) functional parameters represent a tool for risk stratification in patients with congestive heart failure caused by left heart disease. Little is known about RV alterations in dogs with left-sided cardiac disorders. To assess RV and left ventricular (LV) function in dogs with myxomatous mitral valve disease (MMVD) with or without pulmonary hypertension (PH). One-hundred and fourteen dogs: 28 healthy controls and 86 dogs with MMVD at different stages. Prospective observational study. Animals were classified as healthy or having MMVD at different stages of severity and according to presence or absence of PH. Twenty-eight morphological, echo-Doppler, and tissue Doppler imaging (TDI) variables were measured and comparison among groups and correlations between LV and RV parameters were studied. No differences were found among groups regarding RV echo-Doppler and TDI variables. Sixteen significant correlations were found between RV TDI and left heart echocardiographic variables. Dogs with PH had significantly higher transmitral E wave peak velocity and higher E/e' ratio of septal (sMV) and lateral (pMV) mitral annulus. These 2 variables were found to predict presence of PH with a sensitivity of 84 and 72%, and a specificity of 71 and 80% at cut-off values of 10 and 9.33 for sMV E/e' and pMV E/e', respectively. No association between variables of RV function and different MMVD stage and severity of PH could be detected. Some relationships were found between echocardiographic variables of right and left ventricular function. Copyright © 2016 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  2. Ultrasound Pulsed-Wave Doppler Detects an Intrathecal Location of an Epidural Catheter Tip: A Case Report.

    Science.gov (United States)

    Elsharkawy, Hesham; Saasouh, Wael; Patel, Bimal; Babazade, Rovnat

    2018-04-01

    Currently, no gold standard method exists for localization of an epidural catheter after placement. The technique described in this report uses pulsed-wave Doppler (PWD) ultrasound to identify intrathecal location of an epidural catheter. A thoracic epidural catheter was inserted after multiple trials with inconclusive aspiration and test dose. Ultrasound PWD confirmed no flow in the epidural space and positive flow in the intrathecal space. A fluid aspirate was positive for glucose, reconfirming intrathecal placement. PWD is a potential tool that can be used to locate the tip of an epidural catheter.

  3. Clinical and Echocardiographic Evaluation of Regional Systolic Function Detected by Tissue Doppler Imaging in Hypertrophic Cardiomyopathy

    Directory of Open Access Journals (Sweden)

    A Sadeghpour

    2009-09-01

    Full Text Available Background: Hypertrophic cardiomyopathy (HCM is the most common type of the genetic cardiovasculardiseases. Regarding to tremendous heterogeneity in the phenotypic expression of HCM, which is generally unrelatedto genotype, we aimed to study, clinical and echocardiographic parameters such as Tissue Doppler Imaging(TDI in various subtypes of HCM patients and evaluate the influence of race and gender in Iranian patients.Methods: Patients with HCM underwent a complete clinical and echocardiographic study including TDI toassess regional systolic contraction( in the 12 segments and early diastolic annular velocity (Em from theseptal mitral annulus.Results: The study comprised 41 patients (20 women, mean age = 41 ± 15 years with mean LVEF 55%±4.8%and mean maximal septal thickness 2.07cm. Considering LVOT gradient>30mmHg, hypertrophic obstructivecardiomyopathy (HOCM was found in 18 (45%. Asymmetric septal hypertrophy (ASH existed in 27 patients(67%, systolic anterior motion of anterior mitral leaflet (SAM in 25 persons (64%. Nineteen patients (46.3%were included in NYHA function class (FC II and 6 (14.7% in FC III or higher. We found syncope in 10(24.4%, chest pain in 4 (9.8%, atrial fibrilation in 14.6 % and ventricular arrhythmias in (17.1% of patients.History of ICD was seen in 7 (17.1% and PPM in 9 cases. Mean E’ velocity was 5.44± 1.65 cm/sec and S velocity5.70± 1.49 cm/sec with significant lower S velocity and E’ in syncope patients. Overall, HOCM patients hadgrade II diastolic dysfunction with E/É >15(17.54±7.46. Majority (25 of cases (61% were categorized in typeIII of HCM. RV involvement was observed in 11 patients (28.2%.No significant differences existed betweenprevalence of syncope and dysrhythmia among HCM and HOCM patients.Conclusion: In our study, we found lower detection of latent HOCM, compared to other studies, suggestive ofinadequate use of appropriate provocative maneuvers such as exercise stress echocardiography and amyl

  4. Power Doppler Ultrasonography and Shear Wave Elastography as Complementary Imaging Methods for Suspected Local Breast Cancer Recurrence.

    Science.gov (United States)

    Jales, Rodrigo Menezes; Dória, Maira Teixeira; Serra, Kátia Piton; Miranda, Mila Meneguelli; Menossi, Carlos Alberto; Schumacher, Klaus; Sarian, Luis Otávio

    2018-06-01

    To prospectively investigate the diagnostic accuracy and clinical consequences of power Doppler morphologic criteria and shear wave elastography (SWE) as complementary imaging methods for evaluation of suspected local breast cancer recurrence in the ipsilateral breast or chest wall. Thirty-two breast masses with a suspicion of local breast cancer recurrence on B-mode ultrasonography underwent complementary power Doppler and SWE evaluations. Power Doppler morphologic criteria were classified as avascular, hypovascular, or hypervascular. Shear wave elastography was classified according to a 5-point scale (SWE score) and SWE maximum elasticity. Diagnostic accuracy was assessed by the sensitivity, specificity, and area under the curve. A decision curve analysis assessed clinical consequences of each method. The reference standard for diagnosis was defined as core needle or excisional biopsy. Histopathologic examinations revealed 9 (28.2%) benign and 23 (71.8%) malignant cases. Power Doppler ultrasonography (US) had sensitivity of 34.8% (95% confidence interval [CI], 6.6%-62.9%) and specificity of 45.4% (95% CI, 19.3%-71.5%). The SWE score (≥3) had sensitivity of 87.0% (95% CI, 66.4%-97.2%) and specificity of 44.4% (95% CI, 13.7%-78.8%). The SWE maximum elasticity (velocity > 6.5cm/s) had sensitivity of 87% (95% CI, 66.4%-97.2%) and specificity of 77.8% (95% CI, 40.0% to 97.2%). The areas under the curves for the SWE score and SWE maximum elasticity were 0.71 (95% CI, 0.53-0.87) and 0.82 (95% CI, 0.64-0.93), respectively (P = .32). Power Doppler US is unsuitable for discrimination between local breast cancer recurrence and fibrosis. Although the SWE score and SWE maximum elasticity can make this discrimination, the use of these methods to determine biopsy may lead to poorer clinical outcomes than the current practice of performing biopsies of all suspicious masses. © 2017 by the American Institute of Ultrasound in Medicine.

  5. Prognostic value of systolic mitral annular velocity measured with Doppler tissue imaging in patients with chronic heart failure caused by left ventricular systolic dysfunction

    Science.gov (United States)

    Nikitin, N P; Loh, P H; de Silva, R; Ghosh, J; Khaleva, O Y; Goode, K; Rigby, A S; Alamgir, F; Clark, A L; Cleland, J G F

    2006-01-01

    Objective To assess the prognostic value of various conventional and novel echocardiographic indices in patients with chronic heart failure (CHF) caused by left ventricular (LV) systolic dysfunction. Methods 185 patients with a mean (SD) age of 67 (11) years with CHF and LV ejection fraction < 45% despite optimal pharmacological treatment were prospectively enrolled. The patients underwent two dimensional echocardiography with tissue harmonic imaging to assess global LV systolic function and obtain volumetric data. Transmitral flow was assessed with conventional pulse wave Doppler. Systolic (Sm), early, and late diastolic mitral annular velocities were measured with the use of colour coded Doppler tissue imaging. Results During a median follow up of 32 months (range 24–38 months in survivors), 34 patients died and one underwent heart transplantation. Sm velocity (hazard ratio (HR) 0.648, 95% confidence interval (CI) 0.463 to 0.907, p  =  0.011), diastolic arterial pressure (HR 0.965, 95% CI 0.938 to 0.993, p  =  0.015), serum creatinine (HR 1.006, 95% CI 1.001 to 1.011, p  =  0.023), LV ejection fraction (HR 0.945, 95% CI 0.899 to 0.992, p  =  0.024), age (HR 1.035, 95% CI 1.000 to 1.071, p  =  0.052), LV end systolic volume index (HR 1.009, 95% CI 0.999 to 1.019, p  =  0.067), and restrictive pattern of transmitral flow (HR 0.543, 95% CI 0.278 to 1.061, p  =  0.074) predicted the outcome of death or transplantation on univariate analysis. On multivariate analysis, only Sm velocity (HR 0.648, 95% CI 0.460 to 0.912, p  =  0.013) and diastolic arterial pressure (HR 0.966, 95% CI 0.938 to 0.994, p  =  0.016) emerged as independent predictors of outcome. Conclusions In patients with CHF and LV systolic dysfunction despite optimal pharmacological treatment, the strongest independent echocardiographic predictor of prognosis was Sm velocity measured with quantitative colour coded Doppler tissue

  6. Measurements of ultrasonic waves by means of laser Doppler velocimeter and an experimental study of elastic wave propagation in inhomogeneous media; Laser doppler sokudokei ni yoru choonpa keisoku to ganseki wo mochiita fukinshitsu baishitsu no hado denpa model jikken

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, O; Sato, T [Geological Survey of Japan, Tsukuba (Japan); Lei, X [Dia Consultants Company, Tokyo (Japan)

    1996-05-01

    In the study of seismic wave propagation, a model experimenting technique has been developed using a laser Doppler velocimeter (LDV) as the sensor. This technique, not dependent on conventional piezoelectric devices, only irradiates the specimen with laser to measure the velocity amplitude on the target surface, eliminating the need for close contact between the specimen and sensor. In the experiment, elastic penetration waves with their noise levels approximately 0.05mm/s were observed upon application of vibration of 10{sup 6}-10{sup 5}Hz. The specimen was stainless steel or rock, and waveforms caught by the LDV and piezoelectric device were compared. As the result, it was found that the LDV is a powerful tool for effectively explaining elastic wave propagation in inhomogeneous media. The piezoelectric device fails to reproduce accurately the waves to follow the initial one while the LDV detect the velocity amplitude on the specimen surface in a wide frequency range encouraging the discussion over the quantification of observed waveforms. 10 refs., 7 figs.

  7. Solitary waves of surface plasmon polariton via phase shifts under Doppler broadening and Kerr nonlinearity

    Science.gov (United States)

    Ahmad, S.; Ahmad, A.; Bacha, B. A.; Khan, A. A.; Abdul Jabar, M. S.

    2017-12-01

    Surface Plasmon Polaritons (SPPs) are theoretically investigated at the interface of a dielectric metal and gold. The output pulse from the dielectric is used as the input pulse for the generation of SPPs. The SPPs show soliton-like behavior at the interface. The solitary form of a SPP is maintained under the effects of Kerr nonlinearity, Doppler broadening and Fresnel dragging whereas its phase shift is significantly modified. A 0.3radian phase shift is calculated in the presence of both Kerr nonlinearity and Fresnel dragging in the absence of plasma motion. The phase shift is enhanced to 60radian due to the combined effect of Doppler broadening, Kerr nonlinearity and Fresnel dragging. The results may have significant applications in nano-photonics, optical tweezers, photovoltaic devices, plasmonster and sensing technology.

  8. Utilization of laser Doppler flowmetry and tissue spectrophotometry for burn depth assessment using a miniature swine model.

    Science.gov (United States)

    Lotter, Oliver; Held, Manuel; Schiefer, Jennifer; Werner, Ole; Medved, Fabian; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Jaminet, Patrick; Rothenberger, Jens

    2015-01-01

    Currently, the diagnosis of burn depth is primarily based on a visual assessment and can be dependent on the surgeons' experience. The goal of this study was to determine the ability of laser Doppler flowmeter combined with a tissue spectrophotometer to discriminate burn depth in a miniature swine burn model. Burn injuries of varying depth, including superficial-partial, deep-partial, and full thickness, were created in seven Göttingen minipigs using an aluminium bar (100 °C), which was applied to the abdominal skin for periods of 1, 3, 6, 12, 30, and 60 seconds with gravity alone. The depth of injury was evaluated histologically using hematoxylin and eosin staining. All burns were assessed 3 hours after injury using a device that combines a laser light and a white light to determine blood flow, hemoglobin oxygenation, and relative amount of hemoglobin. The blood flow (41 vs. 124 arbitrary units [AU]) and relative amount of hemoglobin (32 vs. 52 AU) were significantly lower in full thickness compared with superficial-partial thickness burns. However, no significant differences in hemoglobin oxygenation were observed between these depths of burns (61 vs. 60%). These results show the ability of laser Doppler flowmeter and tissue spectrophotometer in combination to discriminate between various depths of injury in the minipig model, suggesting that this device may offer a valuable tool for burn depth assessment influencing burn management. © 2014 by the Wound Healing Society.

  9. Mechanical Dyssynchrony by Tissue Doppler Cross-Correlation is Associated with Risk for Complex Ventricular Arrhythmias after Cardiac Resynchronization Therapy

    DEFF Research Database (Denmark)

    Tayal, Bhupendar; Gorcsan, John; Delgado-Montero, Antonia

    2015-01-01

    BACKGROUND: Tissue Doppler cross-correlation analysis has been shown to be associated with long-term survival after cardiac resynchronization defibrillator therapy (CRT-D). Its association with ventricular arrhythmia (VA) is unknown. METHODS: From two centers 151 CRT-D patients (New York Heart...... Association functional classes II-IV, ejection fraction ≤ 35%, and QRS duration ≥ 120 msec) were prospectively included. Tissue Doppler cross-correlation analysis of myocardial acceleration curves from the basal segments in the apical views both at baseline and 6 months after CRT-D implantation was performed...... with a substantially increased risk for VA (hazard ratio [HR], 4.4; 95% CI, 1.2-16.3; P = .03) and VA or death (HR, 4.0; 95% CI, 1.7-9.6; P = .002) after adjusting for other covariates. Similarly, patients with new dyssynchrony had increased risk for VA (HR, 10.6; 95% CI, 2.8-40.4; P = .001) and VA or death (HR, 5...

  10. Analysis of human skin tissue by millimeter-wave reflectometry

    NARCIS (Netherlands)

    Smulders, P.F.M.

    2013-01-01

    Background/pupose: Millimeter-wave reflectometry is a potentially interesting technique to analyze the human skin in vivo in order to determine the water content locally in the skin. Purpose of this work is to investigate the possibility of skin-tissue differentiation. In addition, it addresses the

  11. Spiral waves characterization: Implications for an automated cardiodynamic tissue characterization.

    Science.gov (United States)

    Alagoz, Celal; Cohen, Andrew R; Frisch, Daniel R; Tunç, Birkan; Phatharodom, Saran; Guez, Allon

    2018-07-01

    Spiral waves are phenomena observed in cardiac tissue especially during fibrillatory activities. Spiral waves are revealed through in-vivo and in-vitro studies using high density mapping that requires special experimental setup. Also, in-silico spiral wave analysis and classification is performed using membrane potentials from entire tissue. In this study, we report a characterization approach that identifies spiral wave behaviors using intracardiac electrogram (EGM) readings obtained with commonly used multipolar diagnostic catheters that perform localized but high-resolution readings. Specifically, the algorithm is designed to distinguish between stationary, meandering, and break-up rotors. The clustering and classification algorithms are tested on simulated data produced using a phenomenological 2D model of cardiac propagation. For EGM measurements, unipolar-bipolar EGM readings from various locations on tissue using two catheter types are modeled. The distance measure between spiral behaviors are assessed using normalized compression distance (NCD), an information theoretical distance. NCD is a universal metric in the sense it is solely based on compressibility of dataset and not requiring feature extraction. We also introduce normalized FFT distance (NFFTD) where compressibility is replaced with a FFT parameter. Overall, outstanding clustering performance was achieved across varying EGM reading configurations. We found that effectiveness in distinguishing was superior in case of NCD than NFFTD. We demonstrated that distinct spiral activity identification on a behaviorally heterogeneous tissue is also possible. This report demonstrates a theoretical validation of clustering and classification approaches that provide an automated mapping from EGM signals to assessment of spiral wave behaviors and hence offers a potential mapping and analysis framework for cardiac tissue wavefront propagation patterns. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Determination of testicular blood flow in camelids using vascular casting and color pulsed-wave Doppler ultrasonography.

    Science.gov (United States)

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  13. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    Directory of Open Access Journals (Sweden)

    Michelle Kutzler

    2011-01-01

    Full Text Available We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV was higher in fertile males compared to infertile males (P=0.0004. In addition, end diastolic velocity (EDV within the supratesticular arteries was higher for fertile males when compared to infertile males (P=0.0325. Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P=0.0104. However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P=0.121. In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P=0.486 and marginal arteries (P=0.144. The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  14. On Lamb and Rayleigh wave convergence in viscoelastic tissues

    Energy Technology Data Exchange (ETDEWEB)

    Nenadic, Ivan Z; Urban, Matthew W; Aristizabal, Sara; Mitchell, Scott A; Humphrey, Tye C; Greenleaf, James F, E-mail: Nenadic.Ivan@mayo.edu [Department of Biomedical Engineering, Mayo Clinic College of Medicine, Rochester, MN, 55905 (United States)

    2011-10-21

    Characterization of the viscoelastic material properties of soft tissue has become an important area of research over the last two decades. Our group has been investigating the feasibility of using a shear wave dispersion ultrasound vibrometry (SDUV) method to excite Lamb waves in organs with plate-like geometry to estimate the viscoelasticity of the medium of interest. The use of Lamb wave dispersion ultrasound vibrometry to quantify the mechanical properties of viscoelastic solids has previously been reported. Two organs, the heart wall and the spleen, can be readily modeled using plate-like geometries. The elasticity of these two organs is important because they change in pathological conditions. Diastolic dysfunction is the inability of the left ventricle (LV) of the heart to supply sufficient stroke volumes into the systemic circulation and is accompanied by the loss of compliance and stiffening of the LV myocardium. It has been shown that there is a correlation between high splenic stiffness in patients with chronic liver disease and strong correlation between spleen and liver stiffness. Here, we investigate the use of the SDUV method to quantify the viscoelasticity of the LV free-wall myocardium and spleen by exciting Rayleigh waves on the organ's surface and measuring the wave dispersion (change of wave velocity as a function of frequency) in the frequency range 40-500 Hz. An equation for Rayleigh wave dispersion due to cylindrical excitation was derived by modeling the excised myocardium and spleen with a homogenous Voigt material plate immersed in a nonviscous fluid. Boundary conditions and wave potential functions were solved for the surface wave velocity. Analytical and experimental convergence between the Lamb and Rayleigh waves is reported in a finite element model of a plate in a fluid of similar density, gelatin plate and excised porcine spleen and left-ventricular free-wall myocardium.

  15. Computed estimates of maximum temperature elevations in fetal tissues during transabdominal pulsed Doppler examinations.

    Science.gov (United States)

    Bly, S H; Vlahovich, S; Mabee, P R; Hussey, R G

    1992-01-01

    Measured characteristics of ultrasonic fields were obtained in submissions from manufacturers of diagnostic ultrasound equipment for devices operating in pulsed Doppler mode. Simple formulae were used with these data to generate upper limits to fetal temperature elevations, delta Tlim, during a transabdominal pulsed Doppler examination. A total of 236 items were analyzed, each item being a console/transducer/operating-mode/intended-use combination, for which the spatial-peak temporal-average intensity, ISPTA, was greater than 500 mW cm-2. The largest calculated delta Tlim values were approximately 1.5, 7.1 and 8.7 degrees C for first-, second- and third-trimester examinations, respectively. The vast majority of items yielded delta Tlim values which were less than 1 degree C in the first trimester. For second- and third-trimester examinations, where heating of fetal bone determines delta Tlim, most delta Tlim values were less than 4 degrees C. The clinical significance of the results is discussed.

  16. Ratio of left ventricular peak E-wave velocity to flow propagation velocity assessed by color M-mode Doppler echocardiography in first myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Seward, J B

    2000-01-01

    OBJECTIVES: To determine the ability of the ratio of peak E-wave velocity to flow propagation velocity (E/Vp) measured with color M-mode Doppler echocardiography to predict in-hospital heart failure and cardiac mortality in an unselected consecutive population with first myocardial infarction (MI...

  17. Evaluation of left ventricular function by tissue Doppler and speckle-derived strain rate echocardiography after percutaneous ductus closure.

    Science.gov (United States)

    Amoogzar, Hamid; Shakiba, Ali Mohammad; Derakhshan, Dorna; Ajami, Gholamhossein; Cheriki, Sirous; Borzouee, Mohammad; Edraki, Mohammad Reza; Mehdizadegan, Nima

    2015-01-01

    The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P closure (P closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.

  18. Tissue Doppler echocardiography in persons with hypertension, diabetes, or ischaemic heart disease: the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Mogelvang, Rasmus; Sogaard, Peter; Pedersen, Sune A

    2009-01-01

    AIMS: To test the hypothesis that echocardiographic tissue Doppler imaging (TDI) reveals reduced myocardial function in hypertension, diabetes, and ischaemic heart disease (IHD) in the general population. METHODS AND RESULTS: Within a large, community-based population study, cardiac function...... and diastolic cardiac function in hypertension [n = 345; LD 10.1 (+/-standard deviation, SD 2.0 mm), P diabetes [n = 65; LD 9.8 (+/-SD 2.2 mm), P ....001] compared with controls [n = 533; LD 11.4 (+/-SD 2.0 mm); E/e' 9.0 (x/SD 1.3)]. This pattern remained significant after adjusting for age, sex, body mass index, heart rate, and the results of conventional echocardiography. CONCLUSION: In the general population, persons with hypertension, diabetes, or IHD...

  19. Assessment of regional systolic and diastolic myocardial function using tissue Doppler and strain imaging in dogs with dilated cardiomyopathy.

    Science.gov (United States)

    Chetboul, Valérie; Gouni, Vassiliki; Sampedrano, Carolina Carlos; Tissier, Renaud; Serres, François; Pouchelon, Jean-Louis

    2007-01-01

    Tissue Doppler Imaging (TDI) or strain (St) imaging could provide sensitive indices for early detection and treatment follow-up of canine dilated cardiomyopathy (DCM). Analysis of TDI and St features in dogs with overt DCM is a prerequisite before using these new criteria in prospective screenings of predisposed families or in clinical trials. Radial and longitudinal right and left myocardial motion, assessed by TDI and St variables, is altered in dogs with DCM. Case records for 26 dogs; 14 with DCM and 12 healthy controls of comparable age and weight were reviewed. A retrospective analysis was conducted of conventional echocardiography, 2-dimensional color TDI, and St imaging data. The DCM group was characterized by decreases in radial and longitudinal systolic velocity gradients of the left ventricular free wall (LVFW), radial and longitudinal absolute values of peak systolic St of the LVFW, and longitudinal systolic right ventricular (RV) velocities (all P canine DCM.

  20. A comparison between 133Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    International Nuclear Information System (INIS)

    Kastrup, J.; Buelow, J.; Lassen, N.A.

    1987-01-01

    Changes in skin blood flow measured by Laser Doppler flowmetry and changes in subcutaneous blood flow measured by 133 Xenon washout technique were compared during activation of the local sympathetic mediated veno-arteriolar vaso-constrictor reflex by lowering the area of investigation below heart level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and 133 Xenon blood flow measurements were performed simultaneously on the sympathetically denervated forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The 133 Xenon method recorded a 44% decrease in blood flow in innervated and unchanged blood flow in denervated subcutaneous tissue during lowering of the extremities. Our results indicate that the Laser Doppler method and 133 Xenon method are not comparable, and that the Laser Doppler method is not useful in measuring local sympathetic mediated blood flow changes. (author)

  1. Comparison between /sup 133/Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    Energy Technology Data Exchange (ETDEWEB)

    Kastrup, J.; Buelow, J.; Lassen, N.A.

    1987-10-01

    Changes in skin blood flow measured by Laser Doppler flowmetry and changes in subcutaneous blood flow measured by /sup 133/Xenon washout technique were compared during activation of the local sympathetic mediated veno-arteriolar vaso-constrictor reflex by lowering the area of investigation below heart level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and /sup 133/Xenon blood flow measurements were performed simultaneously on the sympathetically denervated forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The /sup 133/Xenon method recorded a 44% decrease in blood flow in innervated and unchanged blood flow in denervated subcutaneous tissue during lowering of the extremities. Our results indicate that the Laser Doppler method and /sup 133/Xenon method are not comparable, and that the Laser Doppler method is not useful in measuring local sympathetic mediated blood flow changes.

  2. Continuous wave terahertz reflection imaging of human colorectal tissue

    Science.gov (United States)

    Doradla, Pallavi; Alavi, Karim; Joseph, Cecil S.; Giles, Robert H.

    2013-03-01

    Continuous wave terahertz (THz) imaging has the potential to offer a safe, non-ionizing, and nondestructive medical imaging modality for delineating colorectal cancer. Fresh excisions of normal colon tissue were obtained from surgeries performed at the University of Massachusetts Medical School, Worcester. Reflection measurements of thick sections of colorectal tissues, mounted in an aluminum sample holder, were obtained for both fresh and formalin fixed tissues. The two-dimensional reflection images were acquired by using an optically pumped far-infrared molecular gas laser operating at 584 GHz with liquid Helium cooled silicon bolometer detector. Using polarizers in the experiment both co-polarized and cross-polarized remittance form the samples was collected. Analysis of the images showed the importance of understanding the effects of formalin fixation while determining reflectance level of tissue response. The resulting co- and cross-polarized images of both normal and formalin fixed tissues showed uniform terahertz response over the entire sample area. Initial measurements indicated a co-polarized reflectance of 16%, and a cross-polarized reflectance of 0.55% from fresh excisions of normal colonic tissues.

  3. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Ali, M.; Abid, A.R.; Rehman, T.A.; Masood, A.; Sohail, S.

    2010-01-01

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By applying 2 X 2 table sensitivity was 77.7%, specificity was 80

  4. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ali, M; Abid, A R; Rehman, T A; Masood, A; Sohail, S [Allama Iqbal Medical College/Jinnah Hospital, Lahore(Pakistan)

    2010-10-15

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E < 10 was observed in 31 (51.7%), 11 - 15 in 20 (33.3%) and > 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By

  5. A coordinated study of 1 h mesoscale gravity waves propagating from Logan to Boulder with CRRL Na Doppler lidars and temperature mapper

    Science.gov (United States)

    Lu, Xian; Chen, Cao; Huang, Wentao; Smith, John A.; Chu, Xinzhao; Yuan, Tao; Pautet, Pierre-Dominique; Taylor, Mike J.; Gong, Jie; Cullens, Chihoko Y.

    2015-10-01

    We present the first coordinated study using two lidars at two separate locations to characterize a 1 h mesoscale gravity wave event in the mesopause region. The simultaneous observations were made with the Student Training and Atmospheric Research (STAR) Na Doppler lidar at Boulder, CO, and the Utah State University Na Doppler lidar and temperature mapper at Logan, UT, on 27 November 2013. The high precision possessed by the STAR lidar enabled these waves to be detected in vertical wind. The mean wave amplitudes are ~0.44 m/s in vertical wind and ~1% in relative temperature at altitudes of 82-107 km. Those in the zonal and meridional winds are 6.1 and 5.2 m/s averaged from 84 to 99 km. The horizontal and vertical wavelengths inferred from the mapper and lidars are ~219 ± 4 and 16.0 ± 0.3 km, respectively. The intrinsic period is ~1.3 h for the airglow layer, Doppler shifted by a mean wind of ~17 m/s. The wave packet propagates from Logan to Boulder with an azimuth angle of ~135° clockwise from north and an elevation angle of ~ 3° from the horizon. The observed phase difference between the two locations can be explained by the traveling time of the 1 h wave from Logan to Boulder, which is about ~2.4 h. The wave polarization relations are examined through the simultaneous quantifications of the three wind components and temperature. This study has developed a systematic methodology for fully characterizing mesoscale gravity waves, inspecting their intrinsic properties and validating the derivation of horizontal wave structures by applying multiple instruments from coordinated stations.

  6. In situ monitoring of localized shear stress and fluid flow within developing tissue constructs by Doppler optical coherence tomography

    Science.gov (United States)

    Jia, Yali; Bagnaninchi, Pierre O.; Wang, Ruikang K.

    2008-02-01

    Mechanical stimuli can be introduced to three dimensional (3D) cell cultures by use of perfusion bioreactor. Especially in musculoskeletal tissues, shear stress caused by fluid flow generally increase extra-cellular matrix (ECM) production and cell proliferation. The relationship between the shear stress and the tissue development in situ is complicated because of the non-uniform pore distribution within the cell-seeded scaffold. In this study, we firstly demonstrated that Doppler optical coherence tomography (DOCT) is capable of monitoring localized fluid flow and shear stress in the complex porous scaffold by examining their variation trends at perfusion rate of 5, 8, 10 and 12 ml/hr. Then, we developed the 3D porous cellular constructs, cell-seeded chitosan scaffolds monitored during several days by DOCT. The fiber based fourier domain DOCT employed a 1300 nm superluminescent diode with a bandwidth of 52 nm and a xyz resolution of 20×20×15 μm in free space. This setup allowed us not only to assess the cell growth and ECM deposition by observing their different scattering behaviors but also to further investigate how the cell attachment and ECM production has the effect on the flow shear stress and the relationship between flow rate and shear stress in the developing tissue construct. The possibility to monitor continuously the constructs under perfusion will easily indicate the effect of flow rate or shear stress on the cell viability and cell proliferation, and then discriminate the perfusion parameters affecting the pre-tissue formation rate growth.

  7. Determining the appropriate number and duration of leech therapy in congested tissues using tissue spectrophotometry and laser Doppler flowmetry.

    Science.gov (United States)

    Rothenberger, Jens; Petersen, Wiebke; Schaller, Hans-Eberhard; Held, Manuel

    2016-11-01

    A universal protocol determining the number of leeches and their application time does not exist. The aim of this study, therefore, is to quantify perfusion dynamics in venous congested tissues after leech application to get more detailed information about changes due to leech-induced skin microcirculation and to evaluate the usability of the Oxygen to See (O2C) device in terms of determining the appropriate number of leeches and the duration of therapy. Twelve patients with the need for leech therapy participated in the study. Perfusion dynamics of the congested tissue was assessed using the O2C device, which determines blood flow (BF), the relative amount of hemoglobin (rHB), and the oxygen saturation (SO2). Measurements were carried out before leech application and on various intervals like 10 minutes, one hour, and three hours after leech application. The leech application effectuated after 10 minutes a nonsignificant perfusion improvement, which further increased after one hour with a significant reduction of the relative amount of hemoglobin and a significant increase of blood flow and oxygen saturation (BF= +56.7%; rHB= -25.5%; SO2= +53.7%). After three hours, the values returned to the levels before leech administration. In two cases, in which further administration of leeches within the measurement period was necessary, no substantial perfusion changes were obtained. The results of this study forms a more precise pattern of microcirculatory changes of leech therapy in congested tissues. According to our measurements a venous drainage improvement can be expected in congested tissue one hour after leech administration. The O2C seems to be a useful method to determine the appropriate number and duration of leech therapy. © 2016 by the Wound Healing Society.

  8. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  9. Doppler radar flowmeter

    Science.gov (United States)

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  10. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  11. Doppler Frequency Shift in Ocean Wave Measurements: Frequency Downshift of a Fixed Spectral Wave Number Component by Advection of Wave Orbital Velocity

    National Research Council Canada - National Science Library

    Hwang, Paul

    2006-01-01

    ... at he expected intrinsic frequency in the frequency spectrum measured by a stationary probe. The advection of the wave number component by the orbital current of background waves produces a net downshift in the encounter frequency...

  12. A comparison between 133Xenon washout technique and Laser Doppler flowmetry in the measurement of local vasoconstrictor effects on the microcirculation in subcutaneous tissue and skin

    DEFF Research Database (Denmark)

    Kastrup, J; Bülow, J; Lassen, N A

    1987-01-01

    Changes in skin blood flow measured by Laser Doppler flowmetry and changes in subcutaneous blood flow measured by 133Xenon washout technique were compared during activation of the local sympathetic mediated veno-arteriolar vasoconstrictor reflex by lowering the area of investigation below heart...... forearm, and on the calf with preserved sympathetic nerve supply. The Laser Doppler method registered a 23% reduction in skin blood flow during lowering of the extremities independently of the sympathetic nerve supply to the skin. The 133Xenon method recorded a 44% decrease in blood flow in innervated...... level. The measurements were performed in tissue with and without sympathetic innervation. In five subjects, who all had been cervically sympathectomized for manual hyperhidrosis, the Laser Doppler and 133Xenon blood flow measurements were performed simultaneously on the sympathetically denervated...

  13. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  14. Tissue Doppler Imaging Combined with Advanced 12-Lead ECG Analysis Might Improve Early Diagnosis of Hypertrophic Cardiomyopathy in Childhood

    Science.gov (United States)

    Femlund, E.; Schlegel, T.; Liuba, P.

    2011-01-01

    Optimization of early diagnosis of childhood hypertrophic cardiomyopathy (HCM) is essential in lowering the risk of HCM complications. Standard echocardiography (ECHO) has shown to be less sensitive in this regard. In this study, we sought to assess whether spatial QRS-T angle deviation, which has shown to predict HCM in adults with high sensitivity, and myocardial Tissue Doppler Imaging (TDI) could be additional tools in early diagnosis of HCM in childhood. Methods: Children and adolescents with familial HCM (n=10, median age 16, range 5-27 years), and without obvious hypertrophy but with heredity for HCM (n=12, median age 16, range 4-25 years, HCM or sudden death with autopsy-verified HCM in greater than or equal to 1 first-degree relative, HCM-risk) were additionally investigated with TDI and advanced 12-lead ECG analysis using Cardiax(Registered trademark) (IMED Co Ltd, Budapest, Hungary and Houston). Spatial QRS-T angle (SA) was derived from Kors regression-related transformation. Healthy age-matched controls (n=21) were also studied. All participants underwent thorough clinical examination. Results: Spatial QRS-T angle (Figure/ Panel A) and septal E/Ea ratio (Figure/Panel B) were most increased in HCM group as compared to the HCM-risk and control groups (p less than 0.05). Of note, these 2 variables showed a trend toward higher levels in HCM-risk group than in control group (p=0.05 for E/Ea and 0.06 for QRS/T by ANOVA). In a logistic regression model, increased SA and septal E/Ea ratio appeared to significantly predict both the disease (Chi-square in HCM group: 9 and 5, respectively, p less than 0.05 for both) and the risk for HCM (Chi-square in HCM-risk group: 5 and 4 respectively, p less than 0.05 for both), with further increased predictability level when these 2 variables were combined (Chi-square 10 in HCM group, and 7 in HCM-risk group, p less than 0.01 for both). Conclusions: In this small material, Tissue Doppler Imaging and spatial mean QRS-T angle

  15. Soft-tissue tumor differentiation using 3D power Doppler ultrasonography with echo-contrast medium injection.

    Science.gov (United States)

    Chiou, Hong-Jen; Chou, Yi-Hong; Chen, Wei-Ming; Chen, Winby; Wang, Hsin-Kai; Chang, Cheng-Yen

    2010-12-01

    We aimed to evaluate the ability of 3-dimensional power Doppler ultrasonography to differentiate soft-tissue masses from blood flow and vascularization with contrast medium. Twenty-five patients (mean age, 44.1 years; range, 12-77 years) with a palpable mass were enrolled in this study. Volume data were acquired using linear and convex 3-dimensional probes and contrast medium injected manually by bolus. Data were stored and traced slice by slice for 12 slices. All patients were scanned by the same senior sonologist. The vascular index (VI), flow index (FI), and vascular-flow index (VFI) were automatically calculated after the tumor was completely traced. All tumors were later confirmed by pathology. The study included 8 benign (mean, 36.5 mL; range, 2.4-124 mL) and 17 malignant (mean, 319.4 mL; range, 9.9-1,179.6 mL) tumors. Before contrast medium injection, mean VI, FI and VFI were, respectively, 3.22, 32.26 and 1.07 in benign tumors, and 1.97, 29.33 and 0.67 in malignant tumors. After contrast medium injection, they were, respectively, 20.85, 37.33 and 8.52 in benign tumors, and 40.12, 41.21 and 17.77 in malignant tumors. The mean differences between with and without contrast injection for VI, FI and VFI were, respectively, 17.63, 5.07 and 7.45 in benign tumors, and 38.15, 11.88 and 16.55 in malignant tumors. Tumor volume, VI, FI and VFI were not significantly different between benign and malignant tumors before and after echo-contrast medium injection. However, VI, FI and VFI under self-differentiation (differences between with and without contrast injection) were significantly different between malignant and benign tumors. Three-dimensional power Doppler ultrasound is a valuable tool for differential diagnosis of soft-tissue tumors, especially with the injection of an echo-contrast medium. Copyright © 2010 Elsevier. Published by Elsevier B.V. All rights reserved.

  16. Evaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major.

    Science.gov (United States)

    Saravi, Mehrdad; Tamadoni, Ahmad; Jalalian, Rozita; Mahmoodi-Nesheli, Hassan; Hojati, Mosatafa; Ramezani, Saeed

    2013-01-01

    Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard non-invasive diagnostic test. A total of 100 TM patients with the mean age of 19±7 years and 100 healthy controls 18.8±7 years were evaluated. Conventional echocardiography, TDI, and cardiac MRI T2* were performed in all subjects. TDI measures included myocardial systolic (Sm), early (Em) and late (Am) diastolic velocities at basal and middle segments of septal and lateral LV wall. The TM patients were also subgrouped according to those with iron load (T2* ≤ 20 ms) and those without (T2* > 20 ms), and also severe (T2* ≤ 10 ms) versus the non-severe (T2* ≤ 10 ms). Using T2* cardiovascular MR, abnormal myocardial iron load (T2* ≤ 20 ms) was detected in 84% of the patients and among these, 50% (42/84) had severe (T2* ≤ 10 ms) iron load. The mean T2* was 11.6±8.6 ms (5-36.7). A negative linear correlation existed between transfusion period of patients and T2* levels (r = -0.53, p=0.02). The following TDI measures were lower in patients than in controls: basal septal Am (p<0.05), mid-septal Em and Am (p<0.05), basal lateral Am (p<0.05), mid-lateral LV wall Sm (p<0.05) and Am (p<0.05). Tissue doppler imaging is helpful in predicting the presence of myocardial iron load in Thalassemia patients. Therefore, it can be used for screening of thalassemia major patients.

  17. Synthetic Diagnostic for Doppler Backscattering (DBS) Turbulence Measurements based on Full Wave Simulations

    Science.gov (United States)

    Ernst, D. R.; Rhodes, T. L.; Kubota, S.; Crocker, N.

    2017-10-01

    Plasma full-wave simulations of the DIII-D DBS system including its lenses and mirrors are developed using the GPU-based FDTD2D code, verified against the GENRAY ray-tracing code and TORBEAM paraxial beam code. Our semi-analytic description of the effective spot size for a synthetic diagnostic reveals new focusing and defocusing effects arising from the combined effects of the curvature of the reflecting surface and that of the Gaussian beam wavefront. We compute the DBS transfer function from full-wave simulations to verify these effects. Using the synthetic diagnostic, nonlinear GYRO simulations closely match DBS fluctuation spectra with and without strong electron heating, without adjustment or change in normalization, while both GYRO and GENE also match fluxes in all transport channels. Density gradient driven TEMs that are observed by the DBS diagnostic on DIII-D are reproduced by simulations as a band of discrete toroidal mode numbers which intensify during strong electron heating. Work supported by US DOE under DE-FC02-04ER54698 and DE-FG02-08ER54984.

  18. PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application.

    Science.gov (United States)

    Zhou, Qifa; Xu, Xiaochen; Gottlieb, Emanuel J; Sun, Lei; Cannata, Jonathan M; Ameri, Hossein; Humayun, Mark S; Han, Pengdi; Shung, K Kirk

    2007-03-01

    High-frequency needle ultrasound transducers with an aperture size of 0.4 mm were fabricated using lead magnesium niobate-lead titanate (PMN-33% PT) as the active piezoelectric material. The active element was bonded to a conductive silver particle matching layer and a conductive epoxy backing through direct contact curing. An outer matching layer of parylene was formed by vapor deposition. The active element was housed within a polyimide tube and a 20-gauge needle housing. The magnitude and phase of the electrical impedance of the transducer were 47 omega and -38 degrees, respectively. The measured center frequency and -6 dB fractional bandwidth of the PMN-PT needle transducer were 44 MHz and 45%, respectively. The two-way insertion loss was approximately 15 dB. In vivo high-frequency, pulsed-wave Doppler patterns of blood flow in the posterior portion and in vitro ultrasonic backscatter microscope (UBM) images of the rabbit eye were obtained with the 44-MHz needle transducer.

  19. Physical model experiment for wave field measurements by means of laser Doppler vibrometer. Measurement of three components; Laser Doppler shindokei ni yoru butsuri model jikken. Hado sanseibun no kenshutsu

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, O; Sato, T [Geological Survey of Japan, Tsukuba (Japan); Lei, X [DIA Consultant Co. Ltd., Tokyo (Japan)

    1997-05-27

    In this experiment, a beam incident from an oblique direction is reflected by a spherical lens toward the direction of incidence. When the surface of a matter is vibrated by elastic waves, the spherical lens comes into a translation motion that accompanies the vibration. It follows accordingly that the vibration on the surface of the matter may be detected by sensing the spherical lens travelling speed. Three components of the vibration may be determined if beams are focused at one spot from three directions. Detection of the S-wave component by LDV (laser Doppler vibrometer) discloses the complicated wave field in a heterogeneous material, and this physical model experiment may be utilized in various fields of study. For instance, information about problems that may surface in the field work may be collected beforehand in a physical model experiment for developing an S-wave-aided probing method. For the study of seismic wave propagation in a complicated three-dimensional ground structure, a numerical model is not enough, and a physical model experiment will be an effective method to fulfill the purpose. In the monitoring of cracks in a rock, again, not only elastic wave velocity but also waveform information collected from a physical model experiment should be fully utilized. 6 refs., 6 figs.

  20. Renal tissue damage induced by focused shock waves

    Science.gov (United States)

    Ioritani, N.; Kuwahara, M.; Kambe, K.; Taguchi, K.; Saitoh, T.; Shirai, S.; Orikasa, S.; Takayama, K.; Lush, P. A.

    1990-07-01

    Biological evidence of renal arterial wall damage induced by the microjet due to shock wave-cavitation bubble interaction was demonstrated in living dog kidneys. We also intended to clarify the mechanism of renal tissue damage and the effects of different conditions of shock wave exposure (peak pressure of focused area, number of shots, exposure rate) on the renal tissue damage in comparison to stone disintegration. Disruption of arterial wall was the most remarkable histological change in the focused area of the kidneys. This lesion appeared as if the wall had been punctured by a needle. Large hematoma formation in the renal parenchym, and interstitial hemorrhage seemed to be the results of the arterial lesion. This arterial disorder also led to ischemic necrosis of the tubules surrounding the hematoma. Micro-angiographic examination of extracted kidneys also proved such arterial puncture lesions and ischemic lesions. The number of shots required for model stone disintegration was not inversely proportional to peak pressure. It decreased markedly when peak pressure was above 700 bar. Similarly thenumber of shots for hematoma formation was not inversely proportional to peak pressure, however, this decreased markedly above 500 bar. These results suggested that a hematoma could be formed under a lower peak pressure than that required for stone disintegration.

  1. TISSUE DOPPLER IMAGING OF LONGITUDINAL MOVEMENT OF A FIBROUS RING OF MITRAL VALVE DURING ISOVOLUMIC PERIODS IN LEFT VENTRICULAR HYPERTROPHY

    Directory of Open Access Journals (Sweden)

    B. Amarjagal

    2007-01-01

    Full Text Available Aim. To study change of rate and duration indicators of longitudinal movement of a fibrous ring of mitral valve (MFR during isovolumic contraction (IVC and relaxation (IVR in hypertensive patients with various degree of a left ventricular hypertrophy (LVH.Material and methods. 80 hypertensive patients with moderate LVH (n=40 and severe LVH (n=40 are examined. The control group was presented by 30 healthy volunteers. Transthoracic echocardiography and Tissue Doppler imaging has been performed with ultrasonic tomograph “HDI 5000” (Philips.Results. Increase in LVH (Smm and Е/Еmm associates with reduction in systolic velocity of movement of medial MFR (Smm. There is direct relation with duration of IVC-negative and IVR-positive components and myocardium mass index. Maximal velocity of IVC-positive component increases and maximal velocity of IVR-negative component decreases when LVH is growing.Conclusion. Velocities curves of IVC and IVR were bi-phase both in healthy persons and in hypertensive patients with LVH. Velocity and duration of positive and negative components of IVC and IVR depended on LVH degree.

  2. TISSUE DOPPLER IMAGING OF LONGITUDINAL MOVEMENT OF A FIBROUS RING OF MITRAL VALVE DURING ISOVOLUMIC PERIODS IN LEFT VENTRICULAR HYPERTROPHY

    Directory of Open Access Journals (Sweden)

    B. Amarjagal

    2015-12-01

    Full Text Available Aim. To study change of rate and duration indicators of longitudinal movement of a fibrous ring of mitral valve (MFR during isovolumic contraction (IVC and relaxation (IVR in hypertensive patients with various degree of a left ventricular hypertrophy (LVH.Material and methods. 80 hypertensive patients with moderate LVH (n=40 and severe LVH (n=40 are examined. The control group was presented by 30 healthy volunteers. Transthoracic echocardiography and Tissue Doppler imaging has been performed with ultrasonic tomograph “HDI 5000” (Philips.Results. Increase in LVH (Smm and Е/Еmm associates with reduction in systolic velocity of movement of medial MFR (Smm. There is direct relation with duration of IVC-negative and IVR-positive components and myocardium mass index. Maximal velocity of IVC-positive component increases and maximal velocity of IVR-negative component decreases when LVH is growing.Conclusion. Velocities curves of IVC and IVR were bi-phase both in healthy persons and in hypertensive patients with LVH. Velocity and duration of positive and negative components of IVC and IVR depended on LVH degree.

  3. Can tissue spectrophotometry and laser Doppler flowmetry help to identify patients at risk for wound healing disorders after neck dissection?

    Science.gov (United States)

    Rohleder, Nils H; Flensberg, Sandra; Bauer, Florian; Wagenpfeil, Stefan; Wales, Craig J; Koerdt, Steffen; Wolff, Klaus D; Hölzle, Frank; Steiner, Timm; Kesting, Marco R

    2014-03-01

    Microcirculation and oxygen supply in cervical skin were measured with an optical, noninvasive method in patients with or without radiotherapy before neck dissection. The course of wound healing was monitored after the surgical procedure to identify predictive factors for postoperative wound healing disorders. Tissue spectrophotometry and laser Doppler flowmetry were used to determine capillary oxygen saturation, hemoglobin concentration, blood flow, and blood velocity at 2-mm and 8-mm depths in the cervical skin of 91 patients before neck dissection in a maxillofacial unit of a university hospital in Munich, Germany. Parameters were evaluated for differences between patients with irradiation (24) and without (67) and patients with wound healing disorders (25) and without (66) (univariate or multivariate statistical analyses). Velocity at 2 mm was lower in irradiated skin (P = .016). Flow at 2 mm was higher in patients with wound healing disorders (P = .018). High flow values could help to identify patients at risk for cervical wound healing disorders. Copyright © 2014 Elsevier Inc. All rights reserved.

  4. Relevance of tissue Doppler in the quantification of stress echocardiography for the detection of myocardial ischemia in clinical practice

    Directory of Open Access Journals (Sweden)

    Sicari Rosa

    2005-01-01

    Full Text Available Abstract In the present article we review the main published data on the application of Tissue Doppler Imaging (TDI to stress echocardiography for the detection of myocardial ischemia. TDI has been applied to stress echocardiography in order to overcome the limitations of visual analysis for myocardial ischemia. The introduction of a new technology for clinical routine use should pass through the different phases of scientific assessment from feasibility studies to large multicenter studies, from efficacy to effectiveness studies. Nonetheless the pro-technology bias plays a major role in medicine and expensive and sophisticated techniques are accepted before their real usefulness and incremental value to the available ones is assessed. Apparently, TDI is not exempted by this approach : its applications are not substantiated by strong and sound results. Nonetheless, conventional stress echocardiography for myocardial ischemia detection is heavily criticized on the basis of its subjectivity. Stress echocardiography has a long lasting history and the evidence collected over 20 years positioned it as an established tool for the detection and prognostication of coronary artery disease. The quantitative assessment of myocardial ischemia remains a scientific challenge and a clinical goal but time has not come for these newer ultrasonographic techniques which should be restricted to research laboratories.

  5. Optoheterodyne Doppler measurements of the ballistic expansion of the products of the shock wave-induced surface destruction: Experiment and theory

    International Nuclear Information System (INIS)

    Andriyash, A. V.; Astashkin, M. V.; Baranov, V. K.; Golubinskii, A. G.; Irinichev, D. A.; Kondrat’ev, A. N.; Kuratov, S. E.; Mazanov, V. A.; Rogozkin, D. B.; Stepushkin, S. N.; Khatunkin, V. Yu.

    2016-01-01

    The results of optoheterodyne Doppler measurements of the ballistic expansion of the products of surface destruction under shock-wave loading are presented. The possibility of determining the physical characteristics of a rapidly flying dust cloud, including the microparticle velocities, the microparticle sizes, and the areal density of the dust cloud, is shown. A compact stand for performing experiments on shock-wave loading of metallic samples is described. Shock-wave loading is performed by a 100-µm-thick tantalum flyer plate accelerated to a velocity of 2.8 km/s. As the samples, lead plates having various thicknesses and the same surface roughness are used. At a shock-wave pressure of 31.5 GPa, the destruction products are solid microparticles about 50 µm in size. At a pressure of 42 and 88 GPa, a liquid-drop dust cloud with a particle size of 10–15 µm is formed. To interpret the spectral data on the optoheterodyne Doppler measurements of the expansion of the surface destruction products (spalled fragments, dust microparticles), a transport equation for the function of mutual coherence of a multiply scattered field is used. The Doppler spectra of a backscattered signal are calculated with the model developed for the dust cloud that appears when a shock wave reaches the sample surface at the parameters that are typical of an experimental situation. Qualitative changes are found in the spectra, depending on the optical thickness of the dust cloud. The obtained theoretical results are in agreement with the experimental data.

  6. Optoheterodyne Doppler measurements of the ballistic expansion of the products of the shock wave-induced surface destruction: Experiment and theory

    Energy Technology Data Exchange (ETDEWEB)

    Andriyash, A. V. [All-Russia Research Institute of Automatics (Russian Federation); Astashkin, M. V.; Baranov, V. K.; Golubinskii, A. G.; Irinichev, D. A. [Russian Federal Nuclear Center, All-Russia Research Institute of Experimental Physics (VNIIEF) (Russian Federation); Kondrat’ev, A. N., E-mail: an.kondratev@physics.msu.ru; Kuratov, S. E. [All-Russia Research Institute of Automatics (Russian Federation); Mazanov, V. A. [Russian Federal Nuclear Center, All-Russia Research Institute of Experimental Physics (VNIIEF) (Russian Federation); Rogozkin, D. B. [All-Russia Research Institute of Automatics (Russian Federation); Stepushkin, S. N.; Khatunkin, V. Yu. [Russian Federal Nuclear Center, All-Russia Research Institute of Experimental Physics (VNIIEF) (Russian Federation)

    2016-06-15

    The results of optoheterodyne Doppler measurements of the ballistic expansion of the products of surface destruction under shock-wave loading are presented. The possibility of determining the physical characteristics of a rapidly flying dust cloud, including the microparticle velocities, the microparticle sizes, and the areal density of the dust cloud, is shown. A compact stand for performing experiments on shock-wave loading of metallic samples is described. Shock-wave loading is performed by a 100-µm-thick tantalum flyer plate accelerated to a velocity of 2.8 km/s. As the samples, lead plates having various thicknesses and the same surface roughness are used. At a shock-wave pressure of 31.5 GPa, the destruction products are solid microparticles about 50 µm in size. At a pressure of 42 and 88 GPa, a liquid-drop dust cloud with a particle size of 10–15 µm is formed. To interpret the spectral data on the optoheterodyne Doppler measurements of the expansion of the surface destruction products (spalled fragments, dust microparticles), a transport equation for the function of mutual coherence of a multiply scattered field is used. The Doppler spectra of a backscattered signal are calculated with the model developed for the dust cloud that appears when a shock wave reaches the sample surface at the parameters that are typical of an experimental situation. Qualitative changes are found in the spectra, depending on the optical thickness of the dust cloud. The obtained theoretical results are in agreement with the experimental data.

  7. Reduced systolic performance by tissue Doppler in patients with preserved and abnormal ejection fraction: new insights in chronic heart failure.

    Science.gov (United States)

    García, Edgar H; Perna, Eduardo R; Farías, Eduardo F; Obregón, Ricardo O; Macin, Stella M; Parras, Jorge I; Agüero, Marcelo A; Moratorio, Diego A; Pitzus, Ariel E; Tassano, Eduardo A; Rodriguez, Leonardo

    2006-04-04

    Tissue Doppler imaging (TDI) is useful in the evaluation of systolic and diastolic function. It allows assessment of ventricular dynamics in its longitudinal axis. We sought to investigate the difference in systolic and diastolic longitudinal function in patients with chronic heart failure (CHF) with normal and reduced ejection fraction. One hundred ten outpatients with CHF and 68 controls were included. Ejection fraction (EF) was obtained and longitudinal systolic (S) and diastolic (E' and A') wall velocities were recorded from basal septum. Group A (controls) were normal and CHF patients were classified by EF in Group B1: > 45% and B2: < or = 45%. In A, B1 and B2 the mean S peak was 7.74; 5.45 and 4.89 cm/s (p<0.001); the mean E' peak was 8.56; 5.72 and 6.1 cm/s (p<0.001); and the mean A' peak was 10.2; 7.3 and 5.3 cm/s (p<0.001). Also, isovolumic contraction and relaxation time were different among control and CHF groups, (both p<0.001). The most useful parameters for identifying diastolic CHF were IVRT and S peak, with area under ROC curves of 0.93 and 0.89. The cut-off of 115 ms for IVRT and 5.8 cm/s for S peak showed a sensitivity of 94 and 97%, with a specificity of 82 and 73%, respectively. These findings suggest that impairment of left ventricular systolic function is present even in those with diastolic heart failure, and that abnormalities may have an important role to identifying the condition.

  8. Left ventricular diastolic dyssynchrony assessed with phase analysis of gated myocardial perfusion SPECT: a comparison with tissue Doppler imaging

    International Nuclear Information System (INIS)

    Boogers, Mark J.; Veltman, Caroline E.; Chen, Ji; Garcia, Ernest V.; Bommel, Rutger J. van; Mooyaart, Eline A.Q.; Wall, Ernst E. van der; Schalij, Martin J.; Bax, Jeroen J.; Delgado, Victoria; Younis, Imad Al; Hiel, Bernies van der; Dibbets-Schneider, Petra

    2011-01-01

    The aim of the current study was to evaluate the feasibility of phase analysis on gated myocardial perfusion SPECT (GMPS) for the assessment of left ventricular (LV) diastolic dyssynchrony in a head-to-head comparison with tissue Doppler imaging (TDI). The population consisted of patients with end-stage heart failure of New York Heart Association functional class III or IV with a reduced LV ejection fraction of ≤35%. LV diastolic dyssynchrony was calculated using TDI as the maximal time delay between early peak diastolic velocities of two opposing left ventricle walls (diastolic mechanical delay). Significant LV diastolic dyssynchrony was defined as a diastolic mechanical delay of >55 ms on TDI. Furthermore, phase analysis on GMPS was performed to evaluate LV diastolic dyssynchrony; diastolic phase standard deviation (SD) and histogram bandwidth (HBW) were used as markers of LV diastolic dyssynchrony. A total of 150 patients (114 men, mean age 66.0 ± 10.4 years) with end-stage heart failure were enrolled. Both diastolic phase SD (r = 0.81, p 55 ms) showed significantly larger diastolic phase SD (68.1 ± 13.4 vs. 40.7 ± 14.0 , p < 0.01) and diastolic HBW (230.6 ± 54.3 vs. 129.0 ± 55.6 , p < 0.01) as compared to patients without LV diastolic dyssynchrony on TDI (≤55 ms). Finally, phase analysis on GMPS showed a good intra- and interobserver reproducibility for the determination of diastolic phase SD (ICC 0.97 and 0.88) and diastolic HBW (ICC 0.98 and 0.93). Phase analysis on GMPS showed good correlations with TDI for the assessment of LV diastolic dyssynchrony. (orig.)

  9. Galileo Probe Doppler Residuals as the Wave-Dynamical Signature of Weakly Stable, Downward-Increasing Stratification in Jupiter's Deep Wind Layer

    Science.gov (United States)

    Allison, Michael; Atkinson, David H.; Hansen, James E. (Technical Monitor)

    2001-01-01

    Doppler radio tracking of the Galileo probe-to-orbiter relay, previously analyzed for its in situ measure of Jupiter's zonal wind at the equatorial entry site, also shows a record of significant residual fluctuations apparently indicative of varying vertical motions. Regular oscillations over pressure depth in the residual Doppler measurements of roughly 1-8 Hz (increasing upward), as filtered over a 134 sec window, are most plausibly interpreted as gravity waves, and imply a weak, but downward increasing static stability within the 5 - 20 bar region of Jupiter's atmosphere. A matched extension to deeper levels of an independent inertial stability constraint from the measured vertical wind shear at 1 - 4 bars is roughly consistent with a static stability of approximately 0.5 K/km near the 20 bar level, as independently detected by the probe Atmospheric Structure Instrument.

  10. Shock Wave Propagation in Functionally Graded Mineralized Tissue

    Science.gov (United States)

    Nelms, Matthew; Hodo, Wayne; Livi, Ken; Browning, Alyssa; Crawford, Bryan; Rajendran, A. M.

    2017-06-01

    In this investigation, the effects of shock wave propagation in bone-like biomineralized tissue was investigated. The Alligator gar (Atractosteus spatula) exoskeleton is comprised of many disparate scales that provide a biological analog for potential design of flexible protective material systems. The gar scale is identified as a two-phase, (1) hydroxyapatite mineral and (2) collagen protein, biological composite with two distinct layers where a stiff, ceramic-like ganoine overlays a soft, highly ductile ganoid bone. Previous experimentations has shown significant softening under compressive loading and an asymmetrical stress-strain response for analogous mineralized tissues. The structural features, porosity, and elastic modulus were determined from high-resolution scanning electron microscopy, 3D micro-tomography, and dynamic nanoindentation experiments to develop an idealized computational model for FE simulations. The numerical analysis employed Gurson's yield criterion to determine the influence of porosity and pressure on material strength. Functional gradation of elastic moduli and certain structural features, such as the sawtooth interface, are explicitly modeled to study the plate impact shock profile for a full 3-D analysis using ABAQUS finite element software.

  11. Propagation of gravity waves and spread F in the low-latitude ionosphere over Tucumán, Argentina, by continuous Doppler sounding: First results

    Czech Academy of Sciences Publication Activity Database

    Chum, Jaroslav; Bonomi, F. A. M.; Fišer, Jiří; Cabrera, M. A.; Ezquer, R. G.; Burešová, Dalia; Laštovička, Jan; Baše, Jiří; Hruška, František; Molina, M. G.; Ise, J. E.; Cangemi, J. I.; Šindelářová, Tereza

    2014-01-01

    Roč. 119, č. 8 (2014), s. 6954-6965 ISSN 2169-9380 R&D Projects: GA ČR(CZ) GAP209/12/2440; GA ČR GP13-09778P Institutional support: RVO:68378289 Keywords : low latitude ionosphere * Ionospheric irregularities * equatorial spread F * gravity waves * scintillation * remote sensing * Doppler sounding Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 3.426, year: 2014 http://onlinelibrary.wiley.com/doi/10.1002/2014JA020184/abstract

  12. Myocardial left ventricular dysfunction in patients with systemic lupus erythematosus: new insights from tissue Doppler and strain imaging.

    Science.gov (United States)

    Buss, Sebastian J; Wolf, David; Korosoglou, Grigorios; Max, Regina; Weiss, Celine S; Fischer, Christian; Schellberg, Dieter; Zugck, Christian; Kuecherer, Helmut F; Lorenz, Hanns-Martin; Katus, Hugo A; Hardt, Stefan E; Hansen, Alexander

    2010-01-01

    Systemic lupus erythematosus (SLE) is associated with high cardiovascular morbidity and mortality. Cardiovascular involvement is frequently underestimated by routine imaging techniques. Our aim was to determine if new echocardiographic imaging modalities like tissue Doppler (TDI), strain rate (SRR), and strain (SRI) imaging detect abnormalities in left ventricular (LV) function in asymptomatic patients with SLE. Sixty-seven young patients with SLE (mean age 42 +/- 10 yrs) without typical symptoms or signs of heart failure or angina, and a matched healthy control group (n = 40), underwent standard transthoracic echocardiography, TDI, SRR, and SRI imaging of the LV as well as assessment of disease characteristics. Despite findings within the normal range on routine standard 2-dimensional echocardiography, SLE was associated with significantly impaired systolic and diastolic myocardial velocities of the LV measured by TDI [mean global TDI: systolic (s): 2.9 +/- 0.9 vs 3.9 +/- 0.7 cm/s, p < 0.05; early (e): 4.3 +/- 1.5 vs 6.3 +/- 1.3 cm/s, p < 0.05; late (a): 2.9 +/- 0.8 vs 3.4 +/- 0.8 cm/s, p < 0.05; values +/- SD); SRR (s: -0.8 +/- 0.1 vs -1.1 +/- 0.1 s(-1); e: 1.1 +/- 0.2 vs 1.6 +/- 0.3 s(-1); a: 0.7 +/- 0.1 vs 1.0 +/- 0.2 s(-1); all p < 0.05); and SR (-15.11 +/- 2.2% vs -19.7 +/- 1.9%; p < 0.05) compared to the control group. Further, elevated disease activity, measured with the ECLAM and the SLEDAI score, resulted in significantly lower values for LV longitudinal function measured by SRR and SR, but not by TDI. SLE is associated with a significant impairment of systolic and diastolic LV longitudinal function in patients without cardiac symptoms. New imaging modalities provide earlier insight into cardiovascular involvement in SLE and seem to be superior to standard echocardiography to detect subclinical myocardial disease.

  13. Usefulness of the myocardial performance index determined by tissue Doppler imaging m-mode for predicting mortality in the general population

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Haahr-Pedersen, Sune Ammentorp

    2011-01-01

    The objective of this study was to evaluate the prognostic value of the myocardial performance index (MPI), assessed by color-coded tissue Doppler imaging (TDI) M-mode through the anterior mitral leaflet. Color TDI M-mode through the mitral leaflet is an easy, very fast, and precise method...... ventricular in- and outflow using standard procedures (MPI(conv)) and by color-coded TDI M-mode through the mitral leaflet in the apical 4-chamber view (MPI(TDI)). MPI(TDI) was increased in subjects with coronary heart disease (CHD) compared to controls, even after multivariable adjustment (p

  14. Mechanical dyssynchrony evaluated by tissue Doppler cross-correlation analysis is associated with long-term survival in patients after cardiac resynchronization therapy

    DEFF Research Database (Denmark)

    Risum, Niels; Williams, Eric S; Khouri, Michel G

    2013-01-01

    Aims Pre-implant assessment of longitudinal mechanical dyssynchrony using cross-correlation analysis (XCA) was tested for association with long-term survival and compared with other tissue Doppler imaging (TDI)-derived indices. Methods and results In 131 patients referred for cardiac resynchroniz......Aims Pre-implant assessment of longitudinal mechanical dyssynchrony using cross-correlation analysis (XCA) was tested for association with long-term survival and compared with other tissue Doppler imaging (TDI)-derived indices. Methods and results In 131 patients referred for cardiac......-max was independently associated with improved survival when adjusted for QRS > 150 ms and aetiology {hazard ratio (HR) 0.35 [95% confidence interval (CI) 0.16-0.77], P = 0.01}. Maximal activation delay performed significantly better than Yu index, OWD, and the presence of left bundle branch block (P ..., for difference between parameters). In subgroup analysis, patients without dyssynchrony and QRS between 120 and 150 ms showed a particularly poor survival [HR 4.3 (95% CI 1.46-12.59), P

  15. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  16. Ultrasound Shear Wave Simulation of Breast Tumor Using Nonlinear Tissue Elasticity

    Directory of Open Access Journals (Sweden)

    Dae Woo Park

    2016-01-01

    Full Text Available Shear wave elasticity imaging (SWEI can assess the elasticity of tissues, but the shear modulus estimated in SWEI is often less sensitive to a subtle change of the stiffness that produces only small mechanical contrast to the background tissues. Because most soft tissues exhibit mechanical nonlinearity that differs in tissue types, mechanical contrast can be enhanced if the tissues are compressed. In this study, a finite element- (FE- based simulation was performed for a breast tissue model, which consists of a circular (D: 10 mm, hard tumor and surrounding tissue (soft. The SWEI was performed with 0% to 30% compression of the breast tissue model. The shear modulus of the tumor exhibited noticeably high nonlinearity compared to soft background tissue above 10% overall applied compression. As a result, the elastic modulus contrast of the tumor to the surrounding tissue was increased from 0.46 at 0% compression to 1.45 at 30% compression.

  17. Ultrasound Shear Wave Simulation of Breast Tumor Using Nonlinear Tissue Elasticity.

    Science.gov (United States)

    Park, Dae Woo

    2015-01-01

    Shear wave elasticity imaging (SWEI) can assess the elasticity of tissues, but the shear modulus estimated in SWEI is often less sensitive to a subtle change of the stiffness that produces only small mechanical contrast to the background tissues. Because most soft tissues exhibit mechanical nonlinearity that differs in tissue types, mechanical contrast can be enhanced if the tissues are compressed. In this study, a finite element- (FE-) based simulation was performed for a breast tissue model, which consists of a circular (D: 10 mm, hard) tumor and surrounding tissue (soft). The SWEI was performed with 0% to 30% compression of the breast tissue model. The shear modulus of the tumor exhibited noticeably high nonlinearity compared to soft background tissue above 10% overall applied compression. As a result, the elastic modulus contrast of the tumor to the surrounding tissue was increased from 0.46 at 0% compression to 1.45 at 30% compression.

  18. Gravitational-wave bursts from the nuclei of distant galaxies and quasars: proposal for detection using Doppler tracking of interplanetary spacecraft

    International Nuclear Information System (INIS)

    Thorne, K.S.; Braginsky, V.B.

    1976-01-01

    It is likely that supermassive black holes (Mapprox. =10 6 to 10 10 M/sub sun/) exist in the nuclei of many quasars and galaxies. The collapse which forms these holes and subsequent collisions between them should produce strong, broad-band bursts of gravitational waves: for a source of mass M at the Hubble distance of approx.10 10 light-years, the dimensionless amplitude would be h approx. 2 x 10 -17 x (M/10 6 M/sub sun/), and the duration of the burst would be tauapprox. (90 s) x (M/10 6 M/sub sun/). Such bursts might arrive at Earth as often as 50 times per year: or as rarely as once each 300 years. The detection of such bursts may be possible within the next few years using dual-frequency Doppler tracking of interplanetary spacecraft

  19. Prognostic Value of Cardiac Time Intervals by Tissue Doppler Imaging M-Mode in Patients With Acute ST-Segment-Elevation Myocardial Infarction Treated With Primary Percutaneous Coronary Intervention

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Mogelvang, Rasmus; Søgaard, Peter

    2013-01-01

    Background- Color tissue Doppler imaging M-mode through the mitral leaflet is an easy and precise method to estimate all cardiac time intervals from 1 cardiac cycle and thereby obtain the myocardial performance index (MPI). However, the prognostic value of the cardiac time intervals and the MPI...... assessed by color tissue Doppler imaging M-mode through the mitral leaflet in patients with ST-segment-elevation myocardial infarction (MI) is unknown. Methods and Results- In total, 391 patients were admitted with an ST-segment-elevation MI, treated with primary percutaneous coronary intervention...

  20. Trans-skull ultrasonic Doppler system aided by fuzzy logic

    Science.gov (United States)

    Hata, Yutaka; Nakamura, Masato; Yagi, Naomi; Ishikawa, Tomomoto

    2012-06-01

    This paper describes a trans-skull ultrasonic Doppler system for measuring the blood flow direction in brain under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0 MHz. The system determines the fuzzy degree of blood flow by Doppler Effect, thereby it locates blood vessel. This Doppler Effect is examined by the center of gravity shift of the frequency magnitudes. In in-vitro experiment, a cow bone was employed as the skull, and three silicon tubes were done as blood vessels, and bubble in water as blood. We received the ultrasonic waves through a protein, the skull and silicon tubes in order. In the system, fuzzy degrees are determined with respect to the Doppler shift, amplitude of the waves and attenuation of the tissues. The fuzzy degrees of bone and blood direction are calculated by them. The experimental results showed that the system successfully visualized the skull and flow direction, compared with the location and flow direction of the phantom. Thus, it detected the flow direction by Doppler Effect under skull, and automatically extracted the region of skull and blood vessel.

  1. Spontaneous calcium waves in Bergman glia increase with age and hypoxia and may reduce tissue oxygen.

    Science.gov (United States)

    Mathiesen, Claus; Brazhe, Alexey; Thomsen, Kirsten; Lauritzen, Martin

    2013-02-01

    Glial calcium (Ca(2+)) waves constitute a means to spread signals between glial cells and to neighboring neurons and blood vessels. These waves occur spontaneously in Bergmann glia (BG) of the mouse cerebellar cortex in vivo. Here, we tested three hypotheses: (1) aging and reduced blood oxygen saturation alters wave activity; (2) glial Ca(2+) waves change cerebral oxygen metabolism; and (3) neuronal and glial wave activity is correlated. We used two-photon microscopy in the cerebellar cortexes of adult (8- to 15-week-old) and aging (48- to 80-week-old) ketamine-anesthetized mice after bolus loading with OGB-1/AM and SR101. We report that the occurrence of spontaneous waves is 20 times more frequent in the cerebellar cortex of aging as compared with adult mice, which correlated with a reduction in resting brain oxygen tension. In adult mice, spontaneous glial wave activity increased on reducing resting brain oxygen tension, and ATP-evoked glial waves reduced the tissue O(2) tension. Finally, although spontaneous Purkinje cell (PC) activity was not associated with increased glia wave activity, spontaneous glial waves did affect intracellular Ca(2+) activity in PCs. The increased wave activity during aging, as well as low resting brain oxygen tension, suggests a relationship between glial waves, brain energy homeostasis, and pathology.

  2. Elimination of spiral waves in cardiac tissue by multiple electrical shocks

    NARCIS (Netherlands)

    Panfilov, A.V.; Müller, Stefan C.; Zykov, Vladimir S.; Keener, James P.

    1999-01-01

    We study numerically the elimination of a spiral wave in cardiac tissue by application of multiple shocks of external current. To account for the effect of shocks we apply a recently developed theory for the interaction of the external current with cardiac tissue. We compare two possible feedback

  3. Ecocardiografia por Doppler tecidual no diagnóstico de rejeição após transplante cardíaco Ecocardiografía con Doppler tisular en el diagnóstico de rechazo después de transplante cardíaco Tissue doppler echocardiography in the diagnosis of heart transplantation rejection

    Directory of Open Access Journals (Sweden)

    Marcos Valério Coimbra Resende

    2011-07-01

    ,3%, especificidad de 73,8% (p = 0,001. En el análisis multivariado, la a'LAT (p = 0,001, a'SEP (p = 0,002, relación e'/a' LAT (p = 0,006, relación e'Mitral/e'LAT (p = 0,014, SINF (p = 0,009 fueron predictores de RC > 3A. Obtuvimos un escore con sensibilidad de 88,2%, precisión de 79,6%, y valor predictivo negativo de 92.9% para diagnosticar RC > 3A . El Doppler convencional (flujo mitral y pulmonar venoso no fue relevante para predecir la RC > 3A. CONCLUSIÓN: El estudio de IDT agregó información diagnóstica para predecir RC > 3A cuando fue comparado al Doppler convencional. El modelo basado en IDT puede volverse un método en potencial para detectar RC > 3A después de TC.BACKGROUND: Endomyocardial biopsy (EMB is the gold standard method for the diagnosis of cellular rejection (CR after heart transplantation (HT. OBJECTIVE: To test the hypothesis that tissue Doppler imaging (TDI could detect CR > 3A and add diagnostic information compared to conventional Doppler. METHODS: Fifty-four HT patients underwent 129 EMB and a TDI echocardiographic study within 24 hours. We compared HT patients with CR > 3A versus HT patients with CR 3A in 39/129 (30.2% EMB. The best isolated predictor for CR diagnosis was a'LAT, with a sensitivity of 76.3%, specificity of 73.8% (p = 0.001. In the multivariate analysis, a'LAT (p = 0.001, a'SEP (p = 0.002, e'/a' LAT ratio (p = 0.006, e'Mitral/ e'LAT ratio (p = 0.014, SINF (p = 0.009 predicted CR > 3A. We obtained a score with a sensitivity of 88.2%, accuracy of 79.6% and negative predictive value of 92.9% to diagnose CR > 3A. Conventional Doppler (mitral and pulmonary venous flow was not relevant to predict CR > 3A. CONCLUSION: TDI added diagnostic information to predict CR > 3A compared to conventional Doppler. A TDI-based model could become a potential method to detect CR > 3A after Heart Transplantation.

  4. Laser Doppler imaging, thermographic imaging, and tissue oxygen saturation measurements detect early skin reactions during breast radiotherapy

    Science.gov (United States)

    Harrison, David K.; Harrison, Eileen M.; Newton, David J.; Windsor, Phyllis M.

    2001-05-01

    A range of acute skin reactions, ranging from mild erythema to moist desquamation, can be seen in patients receiving standard fractionated radiotherapy to the breast for conservation therapy of breast carcinoma. In a number of cases these reactions can cause considerable discomfort and seriously affect the patient's quality of life. In previous studies we have used the techniques of laser Doppler imaging, digital thermographic imaging and lightguide spectrophotometry to study oxygen supply and blood flow in inflammatory reactions induced experimentally in forearm skin. The present study is an attempt to use the same techniques to investigate whether any or all of them can detect changes in breast skin very early on in the course of radiotherapy treatment. A further aim of the longer term study is to investigate to what extent these early changes may be able to predict the occurrence later of severe acute or delayed reactions.

  5. Effects of extracorporeal shock wave lithotripsy on the kidney and perinephric tissues: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Song, Kounn Sik; Kim, Kun Sang; Kim, Sae Chul [College of Medicine, Chung-Ang University, Seoul (Korea, Republic of)

    1987-12-15

    Since the first successful treatment of the patient with renal stone by extracorporeal shock wave lithotripsy at the Institute for Surgical Research, West Germany, on February 7, 1980, extracorporeal shock wave lithotripsy (ESWL) has been a non-invasive technique for the treatment of the renal and ureteral calculi. In spite of the fact that the acoustic energy of the focused shock waves must pass through the soft tissues of back, perinephric tissues and renal parenchyme before reaching calculi, little is known about the effects of ESWL in the renal parenchyme and perinephric soft tissues. So we analyzed a pre and post-ESWL computed tomography scans of the kidneys in 130 patients treated at our hospital during a three month period to evaluate the effects of ESWL on the kidney and perinephric soft tissues.

  6. Effects of extracorporeal shock wave lithotripsy on the kidney and perinephric tissues: CT evaluation

    International Nuclear Information System (INIS)

    Song, Kounn Sik; Kim, Kun Sang; Kim, Sae Chul

    1987-01-01

    Since the first successful treatment of the patient with renal stone by extracorporeal shock wave lithotripsy at the Institute for Surgical Research, West Germany, on February 7, 1980, extracorporeal shock wave lithotripsy (ESWL) has been a non-invasive technique for the treatment of the renal and ureteral calculi. In spite of the fact that the acoustic energy of the focused shock waves must pass through the soft tissues of back, perinephric tissues and renal parenchyme before reaching calculi, little is known about the effects of ESWL in the renal parenchyme and perinephric soft tissues. So we analyzed a pre and post-ESWL computed tomography scans of the kidneys in 130 patients treated at our hospital during a three month period to evaluate the effects of ESWL on the kidney and perinephric soft tissues

  7. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  8. Assessment of strain and strain rate by two-dimensional speckle tracking in mice: comparison with tissue Doppler echocardiography and conductance catheter measurements.

    Science.gov (United States)

    Ferferieva, V; Van den Bergh, A; Claus, P; Jasaityte, R; La Gerche, A; Rademakers, F; Herijgers, P; D'hooge, J

    2013-08-01

    This study was designed in order to compare the strain and strain rate deformation parameters assessed by speckle tracking imaging (STI) with those of tissue Doppler imaging (TDI) and conductance catheter measurements in chronic murine models of left ventricular (LV) dysfunction. Twenty-four male C57BL/6J mice were assigned to wild-type (n = 8), myocardial infarction (n = 8) and transaortic constriction (n = 8) groups. Echocardiographic and conductance measurements were simultaneously performed at rest and during dobutamine infusion (5 µg/kg/min) in all animals 10 weeks post-surgery. The LV circumferential strain (Scirc) and the strain rate (SRcirc) were derived from grey scale and tissue Doppler data at frame rates of 224 and 375 Hz, respectively. Scirc and SRcirc by TDI/STI correlated well with the preload recruitable stroke work (PRSW) (r = -0.64 and -0.71 for TDI; r = -0.46 and -0.50 for STI, P < 0.05). Both modalities showed a good agreement with respect to Scirc and SRcirc (r = 0.60 and r = 0.63, P < 0.05). During stress, however, TDI-estimated Scirc and SRcirc values were predominantly higher than those measured by STI (P < 0.05). The similarity of Scirc and SRcirc measurements with respect to the STI/TDI data was examined by the Bland-Altman analysis. In mice, the STI- and TDI-derived strain and strain rate deformation parameters relate closely to intrinsic myocardial function. At low heart rate-to-frame rate ratios (HR/FR), both STI and TDI are equally acceptable for assessing the LV function non-invasively in these animals. At HR/FR (e.g. dobutamine challenge), however, these methods cannot be used interchangeably as STI underestimates S and SR at high values.

  9. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  10. Semiquantitative Evaluation of Extrasynovial Soft Tissue Inflammation in the Shoulders of Patients with Polymyalgia Rheumatica and Elderly-Onset Rheumatoid Arthritis by Power Doppler Ultrasound.

    Science.gov (United States)

    Suzuki, Takeshi; Yoshida, Ryochi; Okamoto, Akiko; Seri, Yu

    2017-01-01

    Objectives . To develop a scoring system for evaluating the extrasynovial soft tissue inflammation of the shoulders in patients with polymyalgia rheumatica (PMR) and elderly-onset rheumatoid arthritis with PMR-like onset (pm-EORA) using ultrasound. Methods . We analyzed stored power Doppler (PD) images obtained by the pretreatment examination of 15 PMR patients and 15 pm-EORA patients. A semiquantitative scoring system for evaluating the severity of PD signals adjacent to the anterior aspect of the subscapularis tendon was designed. Results . A four-point scale scoring for the hyperemia on the subscapularis tendon was proposed as follows in brief: 0 = absent or minimal flow, 1 = single vessel dots or short linear-shape signals, 2 = long linear-shape signals or short zone-shape signals, or 3 = long zone-shape signals. This scoring system showed good intra- and interobserver reliability and good correlation to quantitative pixel-counting evaluation. By using it, we demonstrated that inflammation in PMR is dominantly localized in extrasynovial soft tissue as compared with pm-EORA. Conclusions . We proposed a reliable semiquantitative scoring system using ultrasound for the evaluation of extrasynovial soft tissue inflammation of the shoulders in patients with both PMR and pm-EORA. This system is simple to use and can be utilized in future investigations.

  11. Travelling wave phenomena in non-heterogeneous tissues

    DEFF Research Database (Denmark)

    Pedersen, Michael

    2006-01-01

    Disturbances (or information) propagating in heterogeneous biological tissues (or other media) are often modeled by a partial differential equation of the form $$ u''(t,x) +D(x)u'(t,x) +A(x)u(t,x)=f(t,x), $$ for $ 0...

  12. Ultrasonic wave transmission through healthy and diseased tissues

    International Nuclear Information System (INIS)

    Edee, M.K.A.

    1985-12-01

    We calculated the distribution of the spectral density of the ultrasonic energy transmitted by the reference specimen which was water. Let σsub(i0) 2 be this parameter for the frequency fsub(i). In the same manner, we evaluated σsub(i) 2 for the ultrasonic energy transmitted by the biological tissue. We superposed on the curve Log σsub(i0) 2 =F(fsub(i)), each of the curves Log σsub(i) 2 =F(fsub(i)), corresponding to the different kinds of tissues studied. By doing so, we brought into light a ''zone'' between those curves. The judicious exploitation of that ''zone'' by calculating the spectral density coefficients β, made it possible to differentiate one tissue from another. We compared the results so obtained using a probe vibrating at 1.5 MHz with those we obtained by another probe and another method. Both sets of results are in agreement within an approximation of 10%. (author)

  13. Contactless remote induction of shear waves in soft tissues using a transcranial magnetic stimulation device

    International Nuclear Information System (INIS)

    Grasland-Mongrain, Pol; Miller-Jolicoeur, Erika; Cloutier, Guy; Tang, An; Catheline, Stefan

    2016-01-01

    This study presents the first observation of shear waves induced remotely within soft tissues. It was performed through the combination of a transcranial magnetic stimulation device and a permanent magnet. A physical model based on Maxwell and Navier equations was developed. Experiments were performed on a cryogel phantom and a chicken breast sample. Using an ultrafast ultrasound scanner, shear waves of respective amplitudes of 5 and 0.5 μm were observed. Experimental and numerical results were in good agreement. This study constitutes the framework of an alternative shear wave elastography method. (paper)

  14. Contactless remote induction of shear waves in soft tissues using a transcranial magnetic stimulation device

    Science.gov (United States)

    Grasland-Mongrain, Pol; Miller-Jolicoeur, Erika; Tang, An; Catheline, Stefan; Cloutier, Guy

    2016-03-01

    This study presents the first observation of shear waves induced remotely within soft tissues. It was performed through the combination of a transcranial magnetic stimulation device and a permanent magnet. A physical model based on Maxwell and Navier equations was developed. Experiments were performed on a cryogel phantom and a chicken breast sample. Using an ultrafast ultrasound scanner, shear waves of respective amplitudes of 5 and 0.5 μm were observed. Experimental and numerical results were in good agreement. This study constitutes the framework of an alternative shear wave elastography method.

  15. Comparison of Tissue Stiffness Using Shear Wave Elastography in Men with Normal Testicular Tissue, Testicular Microlithiasis and Testicular Cancer

    DEFF Research Database (Denmark)

    Pedersen, Malene Roland; Møller, Henrik; Osther, Palle Jørn Sloth

    2017-01-01

    Objectives: To compare elastography measurements in men with normal testicular tissue, testicular microlithiasis and testicular cancer. Methods: A total of 248 consecutive patients were included. All men provided written informed consent. Testicular stiffness was assessed using shear wave...... elastography (SWE). Three SWE velocity measurements were assessed in each testicle. The patients were divided into three groups; men with normal testicular tissue (n=130), men with testicular microlithiasis (n=99) and men with testicular cancer (n=19). Results: We found a higher mean velocity in the group...... of patients with testicular cancer (1.92 m/s (95% CI 1.82-2.03)) compared to both the group with normal tissue (0.76 m/s (95% CI: 0.75-0.78)) (ptesticular microlithiasis 0.79 m/s (95% CI: 0.77-0.81) (ptesticular microlithiasis increased stiffness...

  16. Field test of an all-semiconductor laser-based coherent continuous-wave Doppler lidar for wind energy applications

    DEFF Research Database (Denmark)

    Sjöholm, Mikael; Dellwik, Ebba; Hu, Qi

    -produced all-semiconductor laser. The instrument is a coherent continuous-wave lidar with two fixed-focus telescopes for launching laser beams in two different directions. The alternation between the telescopes is achieved by a novel switching technique without any moving parts. Here, we report results from...... signal strength from external atmospheric parameters such as relative humidity and concentrations of atmospheric particles is discussed. This novel lidar instrument design seems to offer a promising low-cost alternative for prevision remote sensing of wind turbine inflow....

  17. Visualization of Lamb Wave Interaction with a 5 mm Fatigue Crack using 1D Ultra High Frequency Laser Doppler Vibrometry

    Science.gov (United States)

    2011-09-01

    detection of a fatigue crack via 3D LDV measurements, both in aluminum plates. All the referenced LDV/guided wave studies made use of PZT or similar...Figure 1a). (b) (a) (c) Figure 1: (a) Test specimen in MTS fatigue test machine, (b) hole with 5 mm crack, (c) PZT placement with...mm thick aluminum plates with a small (1.59 mm) center hole added to facilitate growth of a fatigue crack. One plate was left undamaged while the

  18. Travelling waves in models of neural tissue: from localised structures to periodic waves

    NARCIS (Netherlands)

    Meijer, Hil Gaétan Ellart; Coombes, Stephen

    2014-01-01

    We consider travelling waves (fronts, pulses and periodics) in spatially extended one dimensional neural field models. We demonstrate for an excitatory field with linear adaptation that, in addition to an expected stable pulse solution, a stable anti-pulse can exist. Varying the adaptation strength

  19. Evaluating temperature changes of brain tissue due to induced heating of cell phone waves

    Directory of Open Access Journals (Sweden)

    Farhad Forouharmajd

    2018-01-01

    Full Text Available Background: Worries have recently been increased in the absorption of radiofrequency waves and their destructing effects on human health by increasing use of cell phones (mobile phones. This study performed to determine the thermal changes due to mobile phone radio frequency waves in gray and white brain tissue. Methods: This study is an empirical study, where the thermal changes of electromagnetic waves resulted from cell phones (900 MHZ, specific absorption rate for head 1.18 w/kg on the 15 brain tissue of a cow were analyzed in a compartment with three different thickness of 2 mm, 12 mm, and 22 mm, for 15 min. The Lutron thermometer (model: MT-917 with 0.01°C precision was used for measuring the tissue temperature. For each thickness was measured three times. Data analysis is done by Lutron and MATLAB software packages. Results: In confronting of the tissue with the cell phone, the temperature was increased by 0.53°C in the 2 mm thickness that is the gray matter of the brain, increased by 0.99°C in the 12 mm thickness, and also increased by 0.92°C in the 22 mm thickness. Brain temperature showed higher rates than the base temperature after 15 min of confrontation with cell phone waves in all the three thicknesses. Conclusions: Cell phone radiated radio frequency waves were effective on increasing brain tissue temperature, and this temperature increase has cumulative effect on the tissue, being higher, for some time after the confrontation than the time with no confrontation.

  20. Pulsed Wave Doppler Ultrasound Is Useful to Assess Vasomotor Response in Patients with Multiple System Atrophy and Well Correlated with Tilt Table Study

    Directory of Open Access Journals (Sweden)

    Ke-Vin Chang

    2012-01-01

    Full Text Available The study aim was to assess sympathetic vasomotor response (SVR by using pulsed wave Doppler (PWD ultrasound in patients with multiple system atrophy (MSA and correlate with the tilt table study. We recruited 18 male patients and 10 healthy men as controls. The SVR of the radial artery was evaluated by PWD, using inspiratory cough as a provocative maneuver. The response to head-up tilt was studied by a tilt table with simultaneous heart rate and blood pressure recording. The hemodynamic variables were compared between groups, and were examined by correlation analysis. Regarding SVR, MSA patients exhibited a prolonged latency and less heart rate acceleration following inspiratory cough. Compared with the tilt table test, the elevation of heart rate upon SVR was positively correlated to the increase of heart rate after head-up tilt. The correlation analysis indicated that the magnitude of blood pressure drop from supine to upright was positively associated with the SVR latency but negatively correlated with the heart rate changes upon SVR. The present study demonstrated that blunted heart rate response might explain MSA's vulnerability to postural challenge. PWD may be used to predict cardiovascular response to orthostatic stress upon head-up tilt in MSA patients.

  1. A hybrid stimulation strategy for suppression of spiral waves in cardiac tissue

    Energy Technology Data Exchange (ETDEWEB)

    Xu Binbin, E-mail: xubinbin@hotmail.fr [LE2I, CNRS UMR 5158, Universite de Bourgogne, Dijon (France); Jacquir, Sabir, E-mail: sjacquir@u-bourgogne.fr [LE2I, CNRS UMR 5158, Universite de Bourgogne, Dijon (France); Laurent, Gabriel; Bilbault, Jean-Marie [LE2I, CNRS UMR 5158, Universite de Bourgogne, Dijon (France); Binczak, Stephane, E-mail: stbinc@u-bourgogne.fr [LE2I, CNRS UMR 5158, Universite de Bourgogne, Dijon (France)

    2011-08-15

    Highlights: > Simulation of a cardiac tissue by a modified 2D FitzHugh-Nagumo model. > Stimulation of monophasic impulsions from a grid of electrodes to the cardiac tissue. > Propose a method by modifying the tissue's sodium channels and electrical stimulation. > The method leading to suppress spiral waves without generating new ones. > Optimal parameters of a successful suppression of spiral waves are investigated. - Abstract: Atrial fibrillation (AF) is the most common cardiac arrhythmia whose mechanisms are thought to be mainly due to the self perpetuation of spiral waves (SW). To date, available treatment strategies (antiarrhythmic drugs, radiofrequency ablation of the substrate, electrical cardioversion) to restore and to maintain a normal sinus rhythm have limitations and are associated with AF recurrences. The aim of this study was to assess a way of suppressing SW by applying multifocal electrical stimulations in a simulated cardiac tissue using a 2D FitzHugh-Nagumo model specially convenient for AF investigations. We identified stimulation parameters for successful termination of SW. However, SW reinduction, following the electrical stimuli, leads us to develop a hybrid strategy based on sodium channel modification for the simulated tissue.

  2. Correlation between the tissue Doppler, strain rate, strain imaging during the dobutamine infusion and coronary fractional flow reserve during catheterization: a comparative study.

    Science.gov (United States)

    Dagdelen, Sinan; Yuce, Murat; Emiroglu, Yunus; Ergelen, Mehmet; Pala, Selcuk; Tanalp, Ali Cevat; Izgi, Akin; Kirma, Cevat

    2005-06-22

    Coronary fractional flow reserve (FFR) as an invasive, and dobutamine stress echocardiography (DSE) as a noninvasive technique were used to detect critical coronary stenosis. This study was undertaken to assess correlation between these two techniques by using tissue Doppler, strain rate (SR), and strain imaging (S). In 17 patients (aged 54.9+/-12.6, 4 F), a total of 22 vessels were studied. On dobutamine stress echocardiography, baseline and peak systolic (Sm), early (Em) and late (Am) diastolic myocardial velocities, SR and S were recorded from parasternal view (mid-posterior segment) for radial and apical view (mid-septum) for longitudinal deformation. Then coronary FFR was performed by using intracoronary adenosine infusion, and the value of system were analyzed for longitudinal SR and S values, it had a mild correlation with SR (r = 0.47, p = 0.044) and a good correlation with S (r = 0.66, p = 0.002). The quantification of regional myocardial deformation by using DSE rather than the motion would be more appropriate in detecting the ischemic dysfunctional segment supplied by the critical coronary stenosis. Strain measurement during the dobutamine infusion may provide an information on the FFR results of the culprit vessel.

  3. Spiral wave classification using normalized compression distance: Towards atrial tissue spatiotemporal electrophysiological behavior characterization.

    Science.gov (United States)

    Alagoz, Celal; Guez, Allon; Cohen, Andrew; Bullinga, John R

    2015-08-01

    Analysis of electrical activation patterns such as re-entries during atrial fibrillation (Afib) is crucial in understanding arrhythmic mechanisms and assessment of diagnostic measures. Spiral waves are a phenomena that provide intuitive basis for re-entries occurring in cardiac tissue. Distinct spiral wave behaviors such as stable spiral waves, meandering spiral waves, and spiral wave break-up may have distinct electrogram manifestations on a mapping catheter. Hence, it is desirable to have an automated classification of spiral wave behavior based on catheter recordings for a qualitative characterization of spatiotemporal electrophysiological activity on atrial tissue. In this study, we propose a method for classification of spatiotemporal characteristics of simulated atrial activation patterns in terms of distinct spiral wave behaviors during Afib using two different techniques: normalized compressed distance (NCD) and normalized FFT (NFFTD). We use a phenomenological model for cardiac electrical propagation to produce various simulated spiral wave behaviors on a 2D grid and labeled them as stable, meandering, or breakup. By mimicking commonly used catheter types, a star shaped and a circular shaped both of which do the local readings from atrial wall, monopolar and bipolar intracardiac electrograms are simulated. Virtual catheters are positioned at different locations on the grid. The classification performance for different catheter locations, types and for monopolar or bipolar readings were also compared. We observed that the performance for each case differed slightly. However, we found that NCD performance is superior to NFFTD. Through the simulation study, we showed the theoretical validation of the proposed method. Our findings suggest that a qualitative wavefront activation pattern can be assessed during Afib without the need for highly invasive mapping techniques such as multisite simultaneous electrogram recordings.

  4. Influence of detomidine on atrial fibrillation cycle length measured by intracardiac electrogram recording and by colour tissue Doppler imaging in horses.

    Science.gov (United States)

    Decloedt, A; de Clercq, D; van der Vekens, N; Verheyen, T; Ven, S; van Loon, G

    2016-01-01

    Shortening of atrial fibrillation cycle length (AFCL) is a marker of atrial electrical remodelling due to atrial fibrillation (AF). To investigate the effect of administration of detomidine on AFCL measured invasively from an intra-atrial electrogram (AFCLEGM) and noninvasively by tissue Doppler imaging (AFCLTDI). We hypothesised that detomidine would have no effect on AFCL but would improve the ease of TDI measurements and facilitate noninvasive AFCL determination. Prospective clinical study. Measurements were performed before and after i.v. administration of 7.5 μg/kg bwt detomidine in 33 episodes of AF in 32 horses (582 ± 64 kg bwt, 10 ± 3 years old) referred for electrical cardioversion. The AFCLEGM was measured from a right atrial intracardiac electrogram. The AFCLTDI was measured from atrial colour tissue velocity curves in 5 atrial wall regions. Mean AFCLEGM and AFCLTDI without and with sedation were compared using a repeated-measures linear mixed model with Bonferroni correction for multiple comparisons and calculation of the Bland-Altman mean bias and limits of agreement between AFCLEGM and AFCLTDI. The mean AFCL was significantly increased after sedation, but this increase was very small (mean difference +4 ms). For AFCLTDI measurements, sedation significantly improved the quality of the atrial myocardial velocity curves and the number of AF cycles that could be measured per cardiac cycle. The Bland-Altman bias between AFCLEGM without sedation and AFCLTDI with sedation ranged from -18 to +15 ms depending on wall region. Bland-Altman limits of agreement were similar between AFCLEGM without sedation and AFCLTDI without and with sedation. Therefore, noninvasive AFCLTDI measurements with sedation can be used to estimate the atrial fibrillatory rate. Sedation facilitates noninvasive AFCL measurements but causes a slight increase in AFCL. Noninvasive AFCL measurements can be used as an indicator of atrial electrical remodelling, to study AF

  5. Laser doppler perfusion imaging

    International Nuclear Information System (INIS)

    Waardell, K.

    1992-01-01

    Recording of tissue perfusion is important in assessing the influence of peripheral vascular diseases on the microcirculation. This thesis reports on a laser doppler perfusion imager based on dynamic light scattering in tissue. When a low power He-Ne laser beam sequentally scans the tissue, moving blood cells generate doppler components in the back-scattered light. A fraction of this light is detected by a photodetector and converted into an electrical signal. In the processor, a signal proportional to the tissue perfusion at each measurement site is calculated and stored. When the scanning procedure is completed, a color-coded perfusion image is presented on a monitor. To convert important aspects of the perfusion image into more quantitative parameters, data analysis functions are implemented in the software. A theory describing the dependence of the distance between individual measurement points and detector on the system amplification factor is proposed and correction algorithms are presented. The performance of the laser doppler perfusion imager was evaluated using a flow simulator. A linear relationship between processor output signal and flow through the simulator was demonstrated for blood cell concentrations below 0.2%. The median sampling depth of the laser beam was simulated by a Monte Carlo technique and estimated to 235 μm. The perfusion imager has been used in the clinic to study perfusion changes in port wine stains treated with argon laser and to investigate the intensity and extension of the cutaneous axon reflex response after electrical nerve stimulation. The fact that perfusion can be visualized without touching the tissue implies elimination of sterilization problems, thus simplifying clinical investigations of perfusion in association with diagnosis and treatment of peripheral vascular diseases. 22 refs

  6. Remote Sensing of Aerosol Backscatter and Earth Surface Targets By Use of An Airborne Focused Continuous Wave CO2 Doppler Lidar Over Western North America

    Science.gov (United States)

    Jarzembski, Maurice A.; Srivastava, Vandana; Goodman, H. Michael (Technical Monitor)

    2000-01-01

    Airborne lidar systems are used to determine wind velocity and to measure aerosol or cloud backscatter variability. Atmospheric aerosols, being affected by local and regional sources, show tremendous variability. Continuous wave (cw) lidar can obtain detailed aerosol loading with unprecedented high resolution (3 sec) and sensitivity (1 mg/cubic meter) as was done during the 1995 NASA Multi-center Airborne Coherent Atmospheric Wind Sensor (MACAWS) mission over western North America and the Pacific Ocean. Backscatter variability was measured at a 9.1 micron wavelength cw focused CO2 Doppler lidar for approximately 52 flight hours, covering an equivalent horizontal distance of approximately 30,000 km in the troposphere. Some quasi-vertical backscatter profiles were also obtained during various ascents and descents at altitudes that ranged from approximately 0.1 to 12 km. Similarities and differences for aerosol loading over land and ocean were observed. Mid-tropospheric aerosol backscatter background mode was approximately 6 x 10(exp -11)/ms/r, consistent with previous lidar datasets. While these atmospheric measurements were made, the lidar also retrieved a distinct backscatter signal from the Earth's surface from the unfocused part of the focused cw lidar beam during aircraft rolls. Atmospheric backscatter can be highly variable both spatially and temporally, whereas, Earth-surface backscatter is relatively much less variant and can be quite predictable. Therefore, routine atmospheric backscatter measurements by an airborne lidar also give Earth surface backscatter which can allow for investigating the Earth terrain. In the case where the Earth's surface backscatter is coming from a well-known and fairly uniform region, then it can potentially offer lidar calibration opportunities during flight. These Earth surface measurements over varying Californian terrain during the mission were compared with laboratory backscatter measurements using the same lidar of various

  7. Variações de parâmetros da função diastólica do ventrículo esquerdo de acordo com a idade através da ecocardiografia com Doppler tissular Changes in the parameters of left ventricular diastolic function according to age on tissue Doppler imaging

    Directory of Open Access Journals (Sweden)

    Márcia Duarte Pedone

    2004-12-01

    Full Text Available OBJETIVO: Determinar a correlação entre as velocidades diastólicas do Doppler tissular com a idade em amostra de adultos saudáveis, e correlacionar a idade com as velocidades do fluxo transmitral e de veias pulmonares. MÉTODOS: Estudados, através da ecocardiografia, 51 indivíduos saudáveis, com idades entre 21 e 69 anos e registradas as velocidades miocárdicas diastólicas ao Doppler tissular e determinadas as velocidades dos fluxos transmitral e venoso pulmonar. RESULTADOS: As velocidades miocárdicas diastólicas iniciais septal basal e lateral basal apresentaram correlação inversa com a idade, com r = - 0,40 (p = 0,004 e r = - 0,60 (p = 0,0001 respectivamente. As velocidades atriogênicas do Doppler tissular foram diretamente correlacionadas com a idade, sendo no segmento septal basal r = 0,56 (p = 0,0001 e no segmento lateral basal r = 0,50 (p = 0,0001. As velocidades do fluxo transmitral e do fluxo venoso pulmonar também mostraram correlação com a idade. CONCLUSÃO: Existe correlação entre a idade e as velocidades miocárdicas diastólicas do Doppler tissular e com as velocidades do fluxo transmitral e fluxo venoso pulmonar, demonstrando em indivíduos saudáveis uma variação de parâmetros da função diastólica do ventrículo esquerdo com a evolução natural da idade.OBJECTIVE: To determine the correlation between diastolic velocities on tissue Doppler imaging and age in a sample of healthy adults and to correlate age with the velocities of transmitral and pulmonary vein flows. METHODS: Echocardiographic assessment of 51 healthy individuals, whose ages ranged from 21 to 69 years. The diastolic myocardial velocities were recorded on tissue Doppler imaging. The velocities of the transmitral and pulmonary vein flows were also determined. RESULTS: The initial basal septal and basal lateral diastolic myocardial velocities showed an inverse correlation with age [r = - 0.40 (P = 0.004, and r = - 0.60 (P = 0.0001, respectively

  8. Thermal damage produced by high-irradiance continuous wave CO2 laser cutting of tissue.

    Science.gov (United States)

    Schomacker, K T; Walsh, J T; Flotte, T J; Deutsch, T F

    1990-01-01

    Thermal damage produced by continuous wave (cw) CO2 laser ablation of tissue in vitro was measured for irradiances ranging from 360 W/cm2 to 740 kW/cm2 in order to investigate the extent to which ablative cooling can limit tissue damage. Damage zones thinner than 100 microns were readily produced using single pulses to cut guinea pig skin as well as bovine cornea, aorta, and myocardium. Multiple pulses can lead to increased damage. However, a systematic decrease in damage with irradiance, predicted theoretically by an evaporation model of ablation, was not observed. The damage-zone thickness was approximately constant around the periphery of the cut, consistent with the existence of a liquid layer which stores heat and leads to tissue damage, and with a model of damage and ablation recently proposed by Zweig et al.

  9. Analysis of sports related mTBI injuries caused by elastic wave propagation through brain tissue

    Directory of Open Access Journals (Sweden)

    D Case

    2016-10-01

    Full Text Available Repetitive concussions and sub-concussions suffered by athletes have been linked to a series of sequelae ranging from traumatic encephalopathy to dementia pugilistica. A detailed finite element model of the human head was developed based on standard libraries of medical imaging. The model includes realistic material properties for the brain tissue, bone, soft tissue, and CSF, as well as the structure and properties of a protective helmet. Various impact scenarios were studied, with a focus on the strains/stresses and pressure gradients and concentrations created in the brain tissue due to propagation of waves produced by the impact through the complex internal structure of the human head. This approach has the potential to expand our understanding of the mechanism of brain injury, and to better assess the risk of delayed neurological disorders for tens of thousands of young athletes throughout the world.

  10. Modelling far field pacing for terminating spiral waves pinned to ischaemic heterogeneities in cardiac tissue

    Science.gov (United States)

    Boccia, E.; Luther, S.

    2017-01-01

    In cardiac tissue, electrical spiral waves pinned to a heterogeneity can be unpinned (and eventually terminated) using electric far field pulses and recruiting the heterogeneity as a virtual electrode. While for isotropic media the process of unpinning is much better understood, the case of an anisotropic substrate with different conductivities in different directions still needs intensive investigation. To study the impact of anisotropy on the unpinning process, we present numerical simulations based on the bidomain formulation of the phase I of the Luo and Rudy action potential model modified due to the occurrence of acute myocardial ischaemia. Simulating a rotating spiral wave pinned to an ischaemic heterogeneity, we compare the success of sequences of far field pulses in the isotropic and the anisotropic case for spirals still in transient or in steady rotation states. Our results clearly indicate that the range of pacing parameters resulting in successful termination of pinned spiral waves is larger in anisotropic tissue than in an isotropic medium. This article is part of the themed issue ‘Mathematical methods in medicine: neuroscience, cardiology and pathology’. PMID:28507234

  11. Improvement of adipose tissue-derived cells by low-energy extracorporeal shock wave therapy.

    Science.gov (United States)

    Priglinger, Eleni; Schuh, Christina M A P; Steffenhagen, Carolin; Wurzer, Christoph; Maier, Julia; Nuernberger, Sylvia; Holnthoner, Wolfgang; Fuchs, Christiane; Suessner, Susanne; Rünzler, Dominik; Redl, Heinz; Wolbank, Susanne

    2017-09-01

    Cell-based therapies with autologous adipose tissue-derived cells have shown great potential in several clinical studies in the last decades. The majority of these studies have been using the stromal vascular fraction (SVF), a heterogeneous mixture of fibroblasts, lymphocytes, monocytes/macrophages, endothelial cells, endothelial progenitor cells, pericytes and adipose-derived stromal/stem cells (ASC) among others. Although possible clinical applications of autologous adipose tissue-derived cells are manifold, they are limited by insufficient uniformity in cell identity and regenerative potency. In our experimental set-up, low-energy extracorporeal shock wave therapy (ESWT) was performed on freshly obtained human adipose tissue and isolated adipose tissue SVF cells aiming to equalize and enhance stem cell properties and functionality. After ESWT on adipose tissue we could achieve higher cellular adenosine triphosphate (ATP) levels compared with ESWT on the isolated SVF as well as the control. ESWT on adipose tissue resulted in a significantly higher expression of single mesenchymal and vascular marker compared with untreated control. Analysis of SVF protein secretome revealed a significant enhancement in insulin-like growth factor (IGF)-1 and placental growth factor (PLGF) after ESWT on adipose tissue. Summarizing we could show that ESWT on adipose tissue enhanced the cellular ATP content and modified the expression of single mesenchymal and vascular marker, and thus potentially provides a more regenerative cell population. Because the effectiveness of autologous cell therapy is dependent on the therapeutic potency of the patient's cells, this technology might raise the number of patients eligible for autologous cell transplantation. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  12. Propagation characteristics of laser-induced stress wave in deep tissue for gene transfer

    International Nuclear Information System (INIS)

    Ando, Takahiro; Sato, Shunichi; Takano, Shinta; Ashida, Hiroshi; Obara, Minoru

    2009-01-01

    Propagation characteristics of laser-induced stress waves (LISWs) in tissue and their correlation with properties of gene transfection were investigated for targeted deep-tissue gene therapy. LISWs were generated by irradiating a laser-absorbing material with 532-nm Q-switched Nd:YAG laser pulses; a transparent plastic sheet was attached on the absorbing material for plasma confinement. Temporal pressure profiles of LISWs that were propagated through different thickness tissues were measured with a needle-type hydrophone and propagation of LISWs in water was visualized by shadowgraph technique. The measurements showed that at a laser fluence of 1.2 J/cm 2 with a laser spot diameter of 3 mm, flat wavefront was maintained for up to 5 mm in depth and peak pressure P decreased with increasing tissue thickness d; P was proportional to d -0.54 . Rat dorsal skin was injected with plasmid DNA coding for reporter gene, on which different numbers of excised skin(s) was/were placed, and LISWs were applied from the top of the skins. Efficient gene expression was observed in the skin under the 3 mm thick stacked skins, suggesting that deep-located tissue such as muscle can be transfected by transcutaneous application of LISWs.

  13. Unstable spiral waves and local Euclidean symmetry in a model of cardiac tissue

    International Nuclear Information System (INIS)

    Marcotte, Christopher D.; Grigoriev, Roman O.

    2015-01-01

    This paper investigates the properties of unstable single-spiral wave solutions arising in the Karma model of two-dimensional cardiac tissue. In particular, we discuss how such solutions can be computed numerically on domains of arbitrary shape and study how their stability, rotational frequency, and spatial drift depend on the size of the domain as well as the position of the spiral core with respect to the boundaries. We also discuss how the breaking of local Euclidean symmetry due to finite size effects as well as the spatial discretization of the model is reflected in the structure and dynamics of spiral waves. This analysis allows identification of a self-sustaining process responsible for maintaining the state of spiral chaos featuring multiple interacting spirals

  14. Unstable spiral waves and local Euclidean symmetry in a model of cardiac tissue.

    Science.gov (United States)

    Marcotte, Christopher D; Grigoriev, Roman O

    2015-06-01

    This paper investigates the properties of unstable single-spiral wave solutions arising in the Karma model of two-dimensional cardiac tissue. In particular, we discuss how such solutions can be computed numerically on domains of arbitrary shape and study how their stability, rotational frequency, and spatial drift depend on the size of the domain as well as the position of the spiral core with respect to the boundaries. We also discuss how the breaking of local Euclidean symmetry due to finite size effects as well as the spatial discretization of the model is reflected in the structure and dynamics of spiral waves. This analysis allows identification of a self-sustaining process responsible for maintaining the state of spiral chaos featuring multiple interacting spirals.

  15. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  16. Spiral-wave dynamics in a mathematical model of human ventricular tissue with myocytes and fibroblasts.

    Science.gov (United States)

    Nayak, Alok Ranjan; Shajahan, T K; Panfilov, A V; Pandit, Rahul

    2013-01-01

    Cardiac fibroblasts, when coupled functionally with myocytes, can modulate the electrophysiological properties of cardiac tissue. We present systematic numerical studies of such modulation of electrophysiological properties in mathematical models for (a) single myocyte-fibroblast (MF) units and (b) two-dimensional (2D) arrays of such units; our models build on earlier ones and allow for zero-, one-, and two-sided MF couplings. Our studies of MF units elucidate the dependence of the action-potential (AP) morphology on parameters such as [Formula: see text], the fibroblast resting-membrane potential, the fibroblast conductance [Formula: see text], and the MF gap-junctional coupling [Formula: see text]. Furthermore, we find that our MF composite can show autorhythmic and oscillatory behaviors in addition to an excitable response. Our 2D studies use (a) both homogeneous and inhomogeneous distributions of fibroblasts, (b) various ranges for parameters such as [Formula: see text], and [Formula: see text], and (c) intercellular couplings that can be zero-sided, one-sided, and two-sided connections of fibroblasts with myocytes. We show, in particular, that the plane-wave conduction velocity [Formula: see text] decreases as a function of [Formula: see text], for zero-sided and one-sided couplings; however, for two-sided coupling, [Formula: see text] decreases initially and then increases as a function of [Formula: see text], and, eventually, we observe that conduction failure occurs for low values of [Formula: see text]. In our homogeneous studies, we find that the rotation speed and stability of a spiral wave can be controlled either by controlling [Formula: see text] or [Formula: see text]. Our studies with fibroblast inhomogeneities show that a spiral wave can get anchored to a local fibroblast inhomogeneity. We also study the efficacy of a low-amplitude control scheme, which has been suggested for the control of spiral-wave turbulence in mathematical models for cardiac

  17. Measuring the linear and nonlinear elastic properties of brain tissue with shear waves and inverse analysis.

    Science.gov (United States)

    Jiang, Yi; Li, Guoyang; Qian, Lin-Xue; Liang, Si; Destrade, Michel; Cao, Yanping

    2015-10-01

    We use supersonic shear wave imaging (SSI) technique to measure not only the linear but also the nonlinear elastic properties of brain matter. Here, we tested six porcine brains ex vivo and measured the velocities of the plane shear waves induced by acoustic radiation force at different states of pre-deformation when the ultrasonic probe is pushed into the soft tissue. We relied on an inverse method based on the theory governing the propagation of small-amplitude acoustic waves in deformed solids to interpret the experimental data. We found that, depending on the subjects, the resulting initial shear modulus [Formula: see text] varies from 1.8 to 3.2 kPa, the stiffening parameter [Formula: see text] of the hyperelastic Demiray-Fung model from 0.13 to 0.73, and the third- [Formula: see text] and fourth-order [Formula: see text] constants of weakly nonlinear elasticity from [Formula: see text]1.3 to [Formula: see text]20.6 kPa and from 3.1 to 8.7 kPa, respectively. Paired [Formula: see text] test performed on the experimental results of the left and right lobes of the brain shows no significant difference. These values are in line with those reported in the literature on brain tissue, indicating that the SSI method, combined to the inverse analysis, is an efficient and powerful tool for the mechanical characterization of brain tissue, which is of great importance for computer simulation of traumatic brain injury and virtual neurosurgery.

  18. Scroll-wave dynamics in human cardiac tissue: lessons from a mathematical model with inhomogeneities and fiber architecture.

    Directory of Open Access Journals (Sweden)

    Rupamanjari Majumder

    2011-04-01

    Full Text Available Cardiac arrhythmias, such as ventricular tachycardia (VT and ventricular fibrillation (VF, are among the leading causes of death in the industrialized world. These are associated with the formation of spiral and scroll waves of electrical activation in cardiac tissue; single spiral and scroll waves are believed to be associated with VT whereas their turbulent analogs are associated with VF. Thus, the study of these waves is an important biophysical problem. We present a systematic study of the combined effects of muscle-fiber rotation and inhomogeneities on scroll-wave dynamics in the TNNP (ten Tusscher Noble Noble Panfilov model for human cardiac tissue. In particular, we use the three-dimensional TNNP model with fiber rotation and consider both conduction and ionic inhomogeneities. We find that, in addition to displaying a sensitive dependence on the positions, sizes, and types of inhomogeneities, scroll-wave dynamics also depends delicately upon the degree of fiber rotation. We find that the tendency of scroll waves to anchor to cylindrical conduction inhomogeneities increases with the radius of the inhomogeneity. Furthermore, the filament of the scroll wave can exhibit drift or meandering, transmural bending, twisting, and break-up. If the scroll-wave filament exhibits weak meandering, then there is a fine balance between the anchoring of this wave at the inhomogeneity and a disruption of wave-pinning by fiber rotation. If this filament displays strong meandering, then again the anchoring is suppressed by fiber rotation; also, the scroll wave can be eliminated from most of the layers only to be regenerated by a seed wave. Ionic inhomogeneities can also lead to an anchoring of the scroll wave; scroll waves can now enter the region inside an ionic inhomogeneity and can display a coexistence of spatiotemporal chaos and quasi-periodic behavior in different parts of the simulation domain. We discuss the experimental implications of our study.

  19. [Pilot study of echocardiographic studies using color- and pulsed-wave spectral Doppler methods in blue-crowned amazons (Amazona ventralis) and blue-fronted amazons (Amazona a. aestiva)].

    Science.gov (United States)

    Pees, M; Straub, J; Schumacher, J; Gompf, R; Krautwald-Junghanns, M E

    2005-02-01

    Colour-flow and pulsed-wave spectral Doppler echocardiography was performed on 6 healthy, adult Hispaniolan amazon parrots (Amazona ventralis) and 6 blue-fronted amazon parrots (Amazona a. aestiva) to establish normal reference values. Birds were anesthetized with isoflurane in oxygen and placed in dorsal recumbency. An electrocardiogram was recorded continuously and birds were imaged with a micro-phased-array scanner with a frequency of 7.0 MHz. After assessment of cardiac function in 2-D-echocardiography, blood flow across the left and the right atrioventricular valve and across the aortic valve was determined using color-flow and pulsed-wave spectral Doppler echocardiography. Diastolic inflow (mean value +/- standard deviation) into the left ventricle was 0.17 +/- 0.02 m/s (Hispaniolan amazons) and 0.18 +/- 0.03 m/s (Blue fronted amazons). Diastolic inflow into the right ventricle was 0.22 +/- 0.05 m/s (Hispaniolan amazons) and 0.22 +/- 0.04 m/s (Blue fronted amazons). Velocity across the aortic valve was 0.84 +/- 0.07 m/s (Hispaniolan amazons) and 0.83 +/- 0.08 m/s (Blue fronted amazons). Systolic pulmonary flow could not be detected in any of the birds in this study. No significant differences were evident between the two species examined. Results of this study indicate that Doppler echocardiography is a promising technique to determine blood flow in the avian heart. Further studies in other avian species are needed to establish reference values for assessment of cardiac function in diseased birds.

  20. Influence of immune-mediated hemolytic anemia on flow velocities in the portal vein and caudal vena cava measured by use of pulsed-wave Doppler ultrasonography in dogs.

    Science.gov (United States)

    Smith, Rachel Policelli; Koenigshof, Amy M; Smith, Daniel J; Strom, Phillip R; Nelson, Nathan C

    2018-05-01

    OBJECTIVE To compare blood flow velocities of the portal vein (PV) and caudal vena cava (CVC) measured by use of pulsed-wave Doppler ultrasonography in clinically normal dogs and dogs with primary immune-mediated hemolytic anemia (IMHA). ANIMALS 11 client-owned dogs admitted to a veterinary teaching hospital for management of primary IMHA and 21 staff- or student-owned clinically normal dogs. PROCEDURES Flow velocities in the PV and CVC at the porta hepatis were evaluated in conscious unsedated dogs with concurrent ECG monitoring; evaluations were performed before dogs with IMHA received heparin or blood transfusions. Three measurements of peak velocity at end expiration were obtained for each vessel, and the mean was calculated. Results were compared between IMHA and control groups. RESULTS Mean ± SD blood flow velocity in the CVC differed between control (63.0 ± 18.6 cm/s) and IMHA (104 ± 36.9 cm/s) groups. Variance in dogs with IMHA was significantly greater than that for the clinically normal dogs. No significant difference in blood flow velocity in the PV was detected between IMHA and control dogs. CONCLUSIONS AND CLINICAL RELEVANCE Higher blood flow velocities were detected by use of pulsed-wave Doppler ultrasonography in the CVC of dogs with naturally occurring IMHA and may be used to predict anemia in patients suspected of having IMHA.

  1. Concordance and reproducibility between M-mode, tissue Doppler imaging, and two-dimensional strain imaging in the assessment of mitral annular displacement and velocity in patients with various heart conditions

    DEFF Research Database (Denmark)

    de Knegt, Martina Chantal; Biering-Sorensen, Tor; Sogaard, Peter

    2014-01-01

    AIMS: Mitral annular (MA) displacement reflects longitudinal left ventricular (LV) deformation and systolic velocity measurements reflect the rate of contraction; both are valuable in the diagnosis and prognosis of cardiac disease. The aim of this study was to test the agreement and reproducibility...... between motion mode (M-mode), colour tissue Doppler imaging (TDI), and two-dimensional strain imaging (2DSI) when measuring MA displacement and systolic velocity. METHODS AND RESULTS: Using GE Healthcare Vivid 7 and E9 and Echopac BT11 software, MA displacement and velocity measurements by 2DSI, TDI...

  2. Doppler Velocity Signatures of Idealized Elliptical Vortices

    Directory of Open Access Journals (Sweden)

    Wen-Chau Lee

    2006-01-01

    Full Text Available Doppler radar observations have revealed a class of atmospheric vortices (tropical cyclones, tornadoes, dust devils that possess elliptical radar reflectivity signatures. One famous example is Typhoon Herb (1996 that maintained its elliptical reflectivity structure over a 40-hour period. Theoretical work and dual-Doppler analyses of observed tropical cyclones have suggested two physical mechanisms that can explain the formation of two types of elliptical vortices observed in nature, namely, the combination of a circular vortex with either a wavenumber two vortex Rossby wave or a deformation field. The characteristics of these two types of elliptical vortices and their corresponding Doppler velocity signatures have not been previously examined.

  3. Preliminary simulation study of doppler reflectometry

    International Nuclear Information System (INIS)

    Ishii, Yuta; Hojo, Hitoshi; Yoshikawa, Masashi; Ichimura, Makoto; Haraguchi, Yusuke; Imai, Tsuyoshi; Mase, Atsushi

    2010-01-01

    A preliminary simulation study of Doppler reflectometry is performed. The simulations solve Maxwell's equations by a finite difference time domain (FDTD) code method in two dimensions. A moving corrugated metal target is used as a plasma cutoff layer to study the basic features of Doppler reflectometry. We examined the effects of the full width at half maximum (FWHM) of the electromagnetic waves and the corrugation depth of the metal target. Furthermore, the effect of a nonuniform plasma is studied using this FDTD analysis. The Doppler shift and velocity are compared with those obtained from FDTD analysis of a uniform plasma. (author)

  4. Optical coherence tomography detection of shear wave propagation in inhomogeneous tissue equivalent phantoms and ex-vivo carotid artery samples

    Science.gov (United States)

    Razani, Marjan; Luk, Timothy W.H.; Mariampillai, Adrian; Siegler, Peter; Kiehl, Tim-Rasmus; Kolios, Michael C.; Yang, Victor X.D.

    2014-01-01

    In this work, we explored the potential of measuring shear wave propagation using optical coherence elastography (OCE) in an inhomogeneous phantom and carotid artery samples based on a swept-source optical coherence tomography (OCT) system. Shear waves were generated using a piezoelectric transducer transmitting sine-wave bursts of 400 μs duration, applying acoustic radiation force (ARF) to inhomogeneous phantoms and carotid artery samples, synchronized with a swept-source OCT (SS-OCT) imaging system. The phantoms were composed of gelatin and titanium dioxide whereas the carotid artery samples were embedded in gel. Differential OCT phase maps, measured with and without the ARF, detected the microscopic displacement generated by shear wave propagation in these phantoms and samples of different stiffness. We present the technique for calculating tissue mechanical properties by propagating shear waves in inhomogeneous tissue equivalent phantoms and carotid artery samples using the ARF of an ultrasound transducer, and measuring the shear wave speed and its associated properties in the different layers with OCT phase maps. This method lays the foundation for future in-vitro and in-vivo studies of mechanical property measurements of biological tissues such as vascular tissues, where normal and pathological structures may exhibit significant contrast in the shear modulus. PMID:24688822

  5. Preliminary tests on a new near-infrared continuous-wave tissue oximeter

    Science.gov (United States)

    Casavola, Claudia; Cicco, Giuseppe; Pirrelli, Anna; Lugara, Pietro M.

    2000-11-01

    We present a preliminary study, in vitro and in vivo, with a novel device for near-infrared tissue oximetry. The light sources used are two quasi-continuous-wave LEDs, emitting at 656 and 851 nm, and the detector is a photodiode. The data are acquired in back-scattering configuration, thus allowing the non-invasive characterization of thick tissues. Stability tests were performed by placing the optical probe on a tissue- like phantom and acquiring data for periods of time ranging from 5 to 40 minutes. No significant drifts in the DC signal were observed after a warm-up period of no more than 10 minutes. We performed reproducibility tests by repositioning the optical probe on the phantom for a number of times. We found a reproducibility better than 5% in the DC signal. We also present the results of a preliminary study conducted in vivo, on the calf muscle of human subjects. We report a comparison of the results obtained with the near-infrared oximeter with the values of blood oxygenation ctO2 measured with conventional chemical tests.

  6. Electro-mechanical dynamics of spiral waves in a discrete 2D model of human atrial tissue.

    Science.gov (United States)

    Brocklehurst, Paul; Ni, Haibo; Zhang, Henggui; Ye, Jianqiao

    2017-01-01

    We investigate the effect of mechano-electrical feedback and atrial fibrillation induced electrical remodelling (AFER) of cellular ion channel properties on the dynamics of spiral waves in a discrete 2D model of human atrial tissue. The tissue electro-mechanics are modelled using the discrete element method (DEM). Millions of bonded DEM particles form a network of coupled atrial cells representing 2D cardiac tissue, allowing simulations of the dynamic behaviour of electrical excitation waves and mechanical contraction in the tissue. In the tissue model, each cell is modelled by nine particles, accounting for the features of individual cellular geometry; and discrete inter-cellular spatial arrangement of cells is also considered. The electro-mechanical model of a human atrial single-cell was constructed by strongly coupling the electrophysiological model of Colman et al. to the mechanical myofilament model of Rice et al., with parameters modified based on experimental data. A stretch-activated channel was incorporated into the model to simulate the mechano-electrical feedback. In order to investigate the effect of mechano-electrical feedback on the dynamics of spiral waves, simulations of spiral waves were conducted in both the electromechanical model and the electrical-only model in normal and AFER conditions, to allow direct comparison of the results between the models. Dynamics of spiral waves were characterized by tracing their tip trajectories, stability, excitation frequencies and meandering range of tip trajectories. It was shown that the developed DEM method provides a stable and efficient model of human atrial tissue with considerations of the intrinsically discrete and anisotropic properties of the atrial tissue, which are challenges to handle in traditional continuum mechanics models. This study provides mechanistic insights into the complex behaviours of spiral waves and the genesis of atrial fibrillation by showing an important role of the mechano

  7. Electro-mechanical dynamics of spiral waves in a discrete 2D model of human atrial tissue.

    Directory of Open Access Journals (Sweden)

    Paul Brocklehurst

    Full Text Available We investigate the effect of mechano-electrical feedback and atrial fibrillation induced electrical remodelling (AFER of cellular ion channel properties on the dynamics of spiral waves in a discrete 2D model of human atrial tissue. The tissue electro-mechanics are modelled using the discrete element method (DEM. Millions of bonded DEM particles form a network of coupled atrial cells representing 2D cardiac tissue, allowing simulations of the dynamic behaviour of electrical excitation waves and mechanical contraction in the tissue. In the tissue model, each cell is modelled by nine particles, accounting for the features of individual cellular geometry; and discrete inter-cellular spatial arrangement of cells is also considered. The electro-mechanical model of a human atrial single-cell was constructed by strongly coupling the electrophysiological model of Colman et al. to the mechanical myofilament model of Rice et al., with parameters modified based on experimental data. A stretch-activated channel was incorporated into the model to simulate the mechano-electrical feedback. In order to investigate the effect of mechano-electrical feedback on the dynamics of spiral waves, simulations of spiral waves were conducted in both the electromechanical model and the electrical-only model in normal and AFER conditions, to allow direct comparison of the results between the models. Dynamics of spiral waves were characterized by tracing their tip trajectories, stability, excitation frequencies and meandering range of tip trajectories. It was shown that the developed DEM method provides a stable and efficient model of human atrial tissue with considerations of the intrinsically discrete and anisotropic properties of the atrial tissue, which are challenges to handle in traditional continuum mechanics models. This study provides mechanistic insights into the complex behaviours of spiral waves and the genesis of atrial fibrillation by showing an important role of

  8. Enabling real-time ultrasound imaging of soft tissue mechanical properties by simplification of the shear wave motion equation.

    Science.gov (United States)

    Engel, Aaron J; Bashford, Gregory R

    2015-08-01

    Ultrasound based shear wave elastography (SWE) is a technique used for non-invasive characterization and imaging of soft tissue mechanical properties. Robust estimation of shear wave propagation speed is essential for imaging of soft tissue mechanical properties. In this study we propose to estimate shear wave speed by inversion of the first-order wave equation following directional filtering. This approach relies on estimation of first-order derivatives which allows for accurate estimations using smaller smoothing filters than when estimating second-order derivatives. The performance was compared to three current methods used to estimate shear wave propagation speed: direct inversion of the wave equation (DIWE), time-to-peak (TTP) and cross-correlation (CC). The shear wave speed of three homogeneous phantoms of different elastic moduli (gelatin by weight of 5%, 7%, and 9%) were measured with each method. The proposed method was shown to produce shear speed estimates comparable to the conventional methods (standard deviation of measurements being 0.13 m/s, 0.05 m/s, and 0.12 m/s), but with simpler processing and usually less time (by a factor of 1, 13, and 20 for DIWE, CC, and TTP respectively). The proposed method was able to produce a 2-D speed estimate from a single direction of wave propagation in about four seconds using an off-the-shelf PC, showing the feasibility of performing real-time or near real-time elasticity imaging with dedicated hardware.

  9. Effect of decimeter waves on brain and surrounding tissue temperature (experimental study)

    Energy Technology Data Exchange (ETDEWEB)

    Malikova, S.N.; Malyshev, V.L.; Balakyreva, V.N.; Gorban' , L.G.

    Temperature changes in brain and surrounding tissue evoked by decimeter waves (DMW) were studied on phantoms (wood shavings wetted with physiological solution), rabbits and dogs under light nembutal anesthesia and on animal cadavers. The data obtained showed that living organisms, in contrast to phantoms, exhibited a response to heat generation of DMW; this was manifested by maintenance of the temperature at certain level or by a tendency to lower it after about a 10 min exposure to DMW. Thus it was shown that there is a functional cooling system in living organisms: increased local blood flow and a specialized cooling system for the brain. Rabbits showed considerably higher brain temperature elevation than the experimental dogs. Overall, the brain temperature upon exposure to DMW depended on the intensity and duration of DMW action as well as on the state of circulating cooling system of the animals. 4 references, 4 figures.

  10. Visualization of spiral and scroll waves in simulated and experimental cardiac tissue

    Science.gov (United States)

    Cherry, E. M.; Fenton, F. H.

    2008-12-01

    The heart is a nonlinear biological system that can exhibit complex electrical dynamics, complete with period-doubling bifurcations and spiral and scroll waves that can lead to fibrillatory states that compromise the heart's ability to contract and pump blood efficiently. Despite the importance of understanding the range of cardiac dynamics, studying how spiral and scroll waves can initiate, evolve, and be terminated is challenging because of the complicated electrophysiology and anatomy of the heart. Nevertheless, over the last two decades advances in experimental techniques have improved access to experimental data and have made it possible to visualize the electrical state of the heart in more detail than ever before. During the same time, progress in mathematical modeling and computational techniques has facilitated using simulations as a tool for investigating cardiac dynamics. In this paper, we present data from experimental and simulated cardiac tissue and discuss visualization techniques that facilitate understanding of the behavior of electrical spiral and scroll waves in the context of the heart. The paper contains many interactive media, including movies and interactive two- and three-dimensional Java appletsDisclaimer: IOP Publishing was not involved in the programming of this software and does not accept any responsibility for it. You download and run the software at your own risk. If you experience any problems with the software, please contact the author directly. To the fullest extent permitted by law, IOP Publishing Ltd accepts no responsibility for any loss, damage and/or other adverse effect on your computer system caused by your downloading and running this software. IOP Publishing Ltd accepts no responsibility for consequential loss..

  11. Initiation and dynamics of a spiral wave around an ionic heterogeneity in a model for human cardiac tissue.

    Science.gov (United States)

    Defauw, Arne; Dawyndt, Peter; Panfilov, Alexander V

    2013-12-01

    In relation to cardiac arrhythmias, heterogeneity of cardiac tissue is one of the most important factors underlying the onset of spiral waves and determining their type. In this paper, we numerically model heterogeneity of realistic size and value and study formation and dynamics of spiral waves around such heterogeneity. We find that the only sustained pattern obtained is a single spiral wave anchored around the heterogeneity. Dynamics of an anchored spiral wave depend on the extent of heterogeneity, and for certain heterogeneity size, we find abrupt regional increase in the period of excitation occurring as a bifurcation. We study factors determining spatial distribution of excitation periods of anchored spiral waves and discuss consequences of such dynamics for cardiac arrhythmias and possibilities for experimental testings of our predictions.

  12. Spiral wave drift and complex-oscillatory spiral waves caused by heterogeneities in two-dimensional in vitro cardiac tissues

    International Nuclear Information System (INIS)

    Woo, Sung-Jae; Hong, Jin Hee; Kim, Tae Yun; Bae, Byung Wook; Lee, Kyoung J

    2008-01-01

    Understanding spiral reentry wave dynamics in cardiac systems is important since it underlies various cardiac arrhythmia including cardiac fibrillation. Primary cultures of dissociated cardiac cells have been a convenient and useful system for studying cardiac wave dynamics, since one can carry out systematic and quantitative studies with them under well-controlled environments. One key drawback of the dissociated cell culture is that, inevitably, some spatial inhomogeneities in terms of cell types and density, and/or the degree of gap junction connectivity, are introduced to the system during the preparation. These unintentional spatial inhomogeneities can cause some non-trivial wave dynamics, for example, the entrainment dynamics among different spiral waves and the generation of complex-oscillatory spiral waves. The aim of this paper is to quantify these general phenomena in an in vitro cardiac system and provide explanations for them with a simple physiological model having some realistic spatial inhomogeneities incorporated

  13. Piecewise parabolic method for simulating one-dimensional shear shock wave propagation in tissue-mimicking phantoms

    Science.gov (United States)

    Tripathi, B. B.; Espíndola, D.; Pinton, G. F.

    2017-11-01

    The recent discovery of shear shock wave generation and propagation in the porcine brain suggests that this new shock phenomenology may be responsible for a broad range of traumatic injuries. Blast-induced head movement can indirectly lead to shear wave generation in the brain, which could be a primary mechanism for injury. Shear shock waves amplify the local acceleration deep in the brain by up to a factor of 8.5, which may tear and damage neurons. Currently, there are numerical methods that can model compressional shock waves, such as comparatively well-studied blast waves, but there are no numerical full-wave solvers that can simulate nonlinear shear shock waves in soft solids. Unlike simplified representations, e.g., retarded time, full-wave representations describe fundamental physical behavior such as reflection and heterogeneities. Here we present a piecewise parabolic method-based solver for one-dimensional linearly polarized nonlinear shear wave in a homogeneous medium and with empirical frequency-dependent attenuation. This method has the advantage of being higher order and more directly extendable to multiple dimensions and heterogeneous media. The proposed numerical scheme is validated analytically and experimentally and compared to other shock capturing methods. A Riemann step-shock problem is used to characterize the numerical dissipation. This dissipation is then tuned to be negligible with respect to the physical attenuation by choosing an appropriate grid spacing. The numerical results are compared to ultrasound-based experiments that measure planar polarized shear shock wave propagation in a tissue-mimicking gelatin phantom. Good agreement is found between numerical results and experiment across a 40 mm propagation distance. We anticipate that the proposed method will be a starting point for the development of a two- and three-dimensional full-wave code for the propagation of nonlinear shear waves in heterogeneous media.

  14. Spontaneous calcium waves in Bergman glia increase with age and hypoxia and may reduce tissue oxygen

    OpenAIRE

    Mathiesen, Claus; Brazhe, Alexey; Thomsen, Kirsten; Lauritzen, Martin

    2012-01-01

    Glial calcium (Ca2+) waves constitute a means to spread signals between glial cells and to neighboring neurons and blood vessels. These waves occur spontaneously in Bergmann glia (BG) of the mouse cerebellar cortex in vivo. Here, we tested three hypotheses: (1) aging and reduced blood oxygen saturation alters wave activity; (2) glial Ca2+ waves change cerebral oxygen metabolism; and (3) neuronal and glial wave activity is correlated. We used two-photon microscopy in the cerebellar cortexes of...

  15. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  16. Anisotropic polyvinyl alcohol hydrogel phantom for shear wave elastography in fibrous biological soft tissue: a multimodality characterization

    International Nuclear Information System (INIS)

    Chatelin, Simon; Bernal, Miguel; Deffieux, Thomas; Papadacci, Clément; Nahas, Amir; Boccara, Claude; Gennisson, Jean-Luc; Tanter, Mickael; Pernot, Mathieu; Flaud, Patrice

    2014-01-01

    Shear wave elastography imaging techniques provide quantitative measurement of soft tissues elastic properties. Tendons, muscles and cerebral tissues are composed of fibers, which induce a strong anisotropic effect on the mechanical behavior. Currently, these tissues cannot be accurately represented by existing elastography phantoms. Recently, a novel approach for orthotropic hydrogel mimicking soft tissues has been developed (Millon et al 2006 J. Biomed. Mater. Res. B 305–11). The mechanical anisotropy is induced in a polyvinyl alcohol (PVA) cryogel by stretching the physical crosslinks of the polymeric chains while undergoing freeze/thaw cycles. In the present study we propose an original multimodality imaging characterization of this new transverse isotropic (TI) PVA hydrogel. Multiple properties were investigated using a large variety of techniques at different scales compared with an isotropic PVA hydrogel undergoing similar imaging and rheology protocols. The anisotropic mechanical (dynamic and static) properties were studied using supersonic shear wave imaging technique, full-field optical coherence tomography (FFOCT) strain imaging and classical linear rheometry using dynamic mechanical analysis. The anisotropic optical and ultrasonic spatial coherence properties were measured by FFOCT volumetric imaging and backscatter tensor imaging, respectively. Correlation of mechanical and optical properties demonstrates the complementarity of these techniques for the study of anisotropy on a multi-scale range as well as the potential of this TI phantom as fibrous tissue-mimicking phantom for shear wave elastographic applications. (paper)

  17. Anisotropic polyvinyl alcohol hydrogel phantom for shear wave elastography in fibrous biological soft tissue: a multimodality characterization

    Science.gov (United States)

    Chatelin, Simon; Bernal, Miguel; Deffieux, Thomas; Papadacci, Clément; Flaud, Patrice; Nahas, Amir; Boccara, Claude; Gennisson, Jean-Luc; Tanter, Mickael; Pernot, Mathieu

    2014-11-01

    Shear wave elastography imaging techniques provide quantitative measurement of soft tissues elastic properties. Tendons, muscles and cerebral tissues are composed of fibers, which induce a strong anisotropic effect on the mechanical behavior. Currently, these tissues cannot be accurately represented by existing elastography phantoms. Recently, a novel approach for orthotropic hydrogel mimicking soft tissues has been developed (Millon et al 2006 J. Biomed. Mater. Res. B 305-11). The mechanical anisotropy is induced in a polyvinyl alcohol (PVA) cryogel by stretching the physical crosslinks of the polymeric chains while undergoing freeze/thaw cycles. In the present study we propose an original multimodality imaging characterization of this new transverse isotropic (TI) PVA hydrogel. Multiple properties were investigated using a large variety of techniques at different scales compared with an isotropic PVA hydrogel undergoing similar imaging and rheology protocols. The anisotropic mechanical (dynamic and static) properties were studied using supersonic shear wave imaging technique, full-field optical coherence tomography (FFOCT) strain imaging and classical linear rheometry using dynamic mechanical analysis. The anisotropic optical and ultrasonic spatial coherence properties were measured by FFOCT volumetric imaging and backscatter tensor imaging, respectively. Correlation of mechanical and optical properties demonstrates the complementarity of these techniques for the study of anisotropy on a multi-scale range as well as the potential of this TI phantom as fibrous tissue-mimicking phantom for shear wave elastographic applications.

  18. Simulation study of melanoma detection in human skin tissues by laser-generated surface acoustic waves.

    Science.gov (United States)

    Chen, Kun; Fu, Xing; Dorantes-Gonzalez, Dante J; Lu, Zimo; Li, Tingting; Li, Yanning; Wu, Sen; Hu, Xiaotang

    2014-01-01

    Air pollution has been correlated to an increasing number of cases of human skin diseases in recent years. However, the investigation of human skin tissues has received only limited attention, to the point that there are not yet satisfactory modern detection technologies to accurately, noninvasively, and rapidly diagnose human skin at epidermis and dermis levels. In order to detect and analyze severe skin diseases such as melanoma, a finite element method (FEM) simulation study of the application of the laser-generated surface acoustic wave (LSAW) technique is developed. A three-layer human skin model is built, where LSAW’s are generated and propagated, and their effects in the skin medium with melanoma are analyzed. Frequency domain analysis is used as a main tool to investigate such issues as minimum detectable size of melanoma, filtering spectra from noise and from computational irregularities, as well as on how the FEM model meshing size and computational capabilities influence the accuracy of the results. Based on the aforementioned aspects, the analysis of the signals under the scrutiny of the phase velocity dispersion curve is verified to be a reliable, a sensitive, and a promising approach for detecting and characterizing melanoma in human skin.

  19. Simulation study of melanoma detection in human skin tissues by laser-generated surface acoustic waves

    Science.gov (United States)

    Chen, Kun; Fu, Xing; Dorantes-Gonzalez, Dante J.; Lu, Zimo; Li, Tingting; Li, Yanning; Wu, Sen; Hu, Xiaotang

    2014-07-01

    Air pollution has been correlated to an increasing number of cases of human skin diseases in recent years. However, the investigation of human skin tissues has received only limited attention, to the point that there are not yet satisfactory modern detection technologies to accurately, noninvasively, and rapidly diagnose human skin at epidermis and dermis levels. In order to detect and analyze severe skin diseases such as melanoma, a finite element method (FEM) simulation study of the application of the laser-generated surface acoustic wave (LSAW) technique is developed. A three-layer human skin model is built, where LSAW's are generated and propagated, and their effects in the skin medium with melanoma are analyzed. Frequency domain analysis is used as a main tool to investigate such issues as minimum detectable size of melanoma, filtering spectra from noise and from computational irregularities, as well as on how the FEM model meshing size and computational capabilities influence the accuracy of the results. Based on the aforementioned aspects, the analysis of the signals under the scrutiny of the phase velocity dispersion curve is verified to be a reliable, a sensitive, and a promising approach for detecting and characterizing melanoma in human skin.

  20. Measurement of tissue-radiation dosage using a thermal steady-state elastic shear wave.

    Science.gov (United States)

    Chang, Sheng-Yi; Hsieh, Tung-Sheng; Chen, Wei-Ru; Chen, Jin-Chung; Chou, Chien

    2017-08-01

    A biodosimeter based on thermal-induced elastic shear wave (TIESW) in silicone acellular porcine dermis (SAPD) at thermal steady state has been proposed and demonstrated. A square slab SAPD treated with ionizing radiation was tested. The SAPD becomes a continuous homogeneous and isotropic viscoelastic medium due to the generation of randomly coiled collagen fibers formed from their bundle-like structure in the dermis. A harmonic TIESW then propagates on the surface of the SAPD as measured by a nanometer-scaled strain-stress response under thermal equilibrium conditions at room temperature. TIESW oscillation frequency was noninvasively measured in real time by monitoring the transverse displacement of the TIESW on the SAPD surface. Because the elastic shear modulus is highly sensitive to absorbed doses of ionizing radiation, this proposed biodosimeter can become a highly sensitive and noninvasive method for quantitatively determining tissue-absorbed dosage in terms of TIESW’s oscillation frequency. Detection sensitivity at 1 cGy and dynamic ranges covering 1 to 40 cGy and 80 to 500 cGy were demonstrated.

  1. Applications of doppler effect in navigation and oceanography

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A.

    The Doppler effect is the change in frequency of the received sound waves/electromagnetic waves when there is a relative motion between the transmitter and the receiver of these waves. This effect is used for diverse applications in different areas...

  2. Tissue elasticity of in vivo skeletal muscles measured in the transverse and longitudinal planes using shear wave elastography.

    Science.gov (United States)

    Chino, Kentaro; Kawakami, Yasuo; Takahashi, Hideyuki

    2017-07-01

    The aim of the present study was to measure in vivo skeletal muscle elasticity in the transverse and longitudinal planes using shear wave elastography and then to compare the image stability, measurement values and measurement repeatability between these imaging planes. Thirty-one healthy males participated in this study. Tissue elasticity (shear wave velocity) of the medial gastrocnemius, rectus femoris, biceps brachii and rectus abdominis was measured in both the transverse and longitudinal planes using shear wave elastography. Image stability was evaluated by the standard deviation of the colour distribution in the shear wave elastography image. Measurement repeatability was assessed by the coefficient of variance obtained from three measurement values. Image stability of all tested muscles was significantly higher in the longitudinal plane (Pplanes (P>0·05), except in the biceps brachii (P = 0·001). Measurement values of the medial gastrocnemius, rectus femoris and biceps brachii were significantly different between the imaging planes (Pplane, which indicates that imaging plane should be considered when measuring skeletal muscle tissue elasticity by shear wave elastography. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  3. Doppler flowmetry in preeclampsia.

    Science.gov (United States)

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  4. [Prostate cancer detection by assessing stiffness of different tissues using shear wave ultrasound elastog- raphy].

    Science.gov (United States)

    Glybochko, P V; Alyaev, Yu G; Amosov, A V; Krupinov, G E; Ganzha, T M; Vorobev, A V; Lumpov, I S; Semendyaev, R I

    2016-08-01

    Early detection of prostate cancer (PCa) remains a challenging issue. There are studies underway aimed to develop and implement new methods for prostate cancer screening by tumor imaging and obtaining tissue samples from suspicious areas for morphological examination. One of these new methods is shear wave ultrasound elastography (SWUE). The current literature is lacking sufficient coverage of informativeness and specificity of SWUE in the prostate cancer detection, there is no clear criteria for assessing tissue stiffness at different values of PSA and tumor grade, and in prostate hyperplasia and prostatitis. To evaluate the informativeness and specificity of SWUE compared with other diagnostic methods. SWUE has been used in the Clinic of Urology of Sechenov First MSMU since October 2015. During this period, 302 patients were examined using SWUE. SWUE was performed with Aixplorer ultrasound system (Super Sonic Imagine), which provides a single-stage SWUE imaging with both B-mode and real-time mode. The first group (prospective study) included 134 men aged 47 to 81 years with suspected prostate cancer scheduled to either initial or repeat prostate biopsy. PSA levels ranged from 4 to 24 ng/ml. The second group (retrospective study) comprised 120 men with confirmed prostate cancer and PSA levels between 4 and 90 ng/ml. The third group (the control group), comprised 48 healthy men whose PSA level did not exceed 3 ng/ml. All patients of the groups 1 and 2 underwent a standard comprehensive examination. Patients in group 1 were subsequently subjected to transrectal prostate biopsy guided by localization of areas with abnormal tissue stiffness. PCa was detected in 100 of 134 patients. 217 patients of groups 1 and 2 underwent radical prostatectomy. In 28 of them, the match between the cancer location and differentiation in the removed prostate and SWUE findings before surgery was examined. Contrast-enhanced magnetic resonance imaging of pelvic organs was performed in 63

  5. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  6. The effects of electromagnetic waves emitted by the cell phones on the testicular tissue

    Directory of Open Access Journals (Sweden)

    Muhammet Ihsan Karaman

    2014-12-01

    Full Text Available Objectives: Various risks have emerged in parallel to the rapidly increasing use of cell phones. Herein we studied the effects of cell phone emitted electromagnetic waves (EMW on rat testes. Material and Methods: Twenty one adult male Albino rats were grouped into 3 groups each consisting of 7 rats. The first group was exposed to EMW on talk mode for 8 hours per day for 20 days and then their testes were extracted. The testes of the second group were extracted after 20 days of whole day EMW exposure. The third group was the control group. For the statistical analysis Mann- Whitney U analysis was performed. Results: At light microscopic examination of the testicular tissue, the existence of a high number of immature cells in the lumen of the seminiferous tubule in addition to the normal seminiferous tubules, besides irregular tubules with a reduction in the spermatogenic cell lines and tubules without lumen were observed in groups 1 and 2. Histopathological alterations were scored as 0 = none, 1 = low, 2 = medium, 3 = serious. The average scores of the three groups were found to be 4.25 ± 1.5 for the group 1, 4.33 ± 3.9 for the group 2 and 0.37 ± 1.1 for the group 3 respectively. As a result of the statistical evaluation, group 1 and group 2 had significantly higher scores than the control group (p = 0.001. Conclusion: Infertility is one of the current problems of today due to a rapid increase in its incidence and cost. The negative effects of the EMWs on the testis should be taken into account and the necessary measures should be taken for prevention.

  7. Evaluation of left ventricular diastolic echocardiographic parameters in healthy dogs by pulsed-wave Doppler Avaliação de parâmetros ecocardiográficos diastólicos do ventrículo esquerdo de cães saudáveis por meio de Doppler pulsátil

    Directory of Open Access Journals (Sweden)

    Guilherme G. Pereira

    2009-04-01

    Full Text Available Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E, peak A wave (peak A, E/A ratio (E/A, E wave deceleration time (EDT and isovolumic relaxation time (IRVT were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT, by age (peak A and E/A and by body weight (TRIV. Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.A disfunção diastólica do ventrículo esquerdo contribui de maneira importante para a progressão da insuficiência cardíaca. No intuito de obter valores de referência adicionais para os parâmetros diastólicos do ventrículo esquerdo e para investigar a influência de variáveis comuns, estudou-se, por meio de Doppler pulsátil, a velocidade máxima da onda E (Vmáx.E, a velocidade máxima da onda A (Vmáx.: A, a relação E/A (E/A, o tempo de desaceleração da onda E (TDE e o tempo de relaxamento isovolumétrico (TRIV em 40 cães clinicamente saudáveis. Os seguintes valores foram obtidos: Vmáx.E = 0,747±0,117m/s, Vmáx.A = 0,487±0,062m/s, E/A = 1,533±0,198, TDE = 88,7±9,2ms e TRIV = 0,080±0,009s. Alguns parâmetros foram influenciados pela freqüência cardíaca (Vmáx.E, Vmáx.A e TRIV, pela idade (Vmáx.A e E/A e pelo peso corpóreo (TRIV. Não houve influência pelo sexo. Os valores obtidos podem ser utilizados como referência para a espécie canina, porém devem ser interpretados considerando-se a influência das variáveis descritas.

  8. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...

  9. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  10. The Cognitive Doppler.

    Science.gov (United States)

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  11. Simulation of nonlinear transient elastography: finite element model for the propagation of shear waves in homogeneous soft tissues.

    Science.gov (United States)

    Ye, W; Bel-Brunon, A; Catheline, S; Combescure, A; Rochette, M

    2018-01-01

    In this study, visco-hyperelastic Landau's model, which is widely used in acoustical physic field, is introduced into a finite element formulation. It is designed to model the nonlinear behaviour of finite amplitude shear waves in soft solids, typically, in biological tissues. This law is used in finite element models based on elastography, experiments reported in Jacob et al, the simulations results show a good agreement with the experimental study: It is observed in both that a plane shear wave generates only odd harmonics and a nonplane wave generates both odd and even harmonics in the spectral domain. In the second part, a parametric study is performed to analyse the influence of different factors on the generation of odd harmonics of plane wave. A quantitative relation is fitted between the odd harmonic amplitudes and the non-linear elastic parameter of Landau's model, which provides a practical guideline to identify the non-linearity of homogeneous tissues using elastography experiment. Copyright © 2017 John Wiley & Sons, Ltd.

  12. Determination of the Elasticity of Breast Tissue during the Menstrual Cycle Using Real-Time Shear Wave Elastography.

    Science.gov (United States)

    Li, Xiang; Wang, Jian-Nan; Fan, Zhi-Ying; Kang, Shu; Liu, Yan-Jun; Zhang, Yi-Xia; Wang, Xue-Mei

    2015-12-01

    We examined breast tissue elasticity during the menstrual cycle using real-time shear wave elastography (RT-SWE), a recent technique developed for soft tissue imaging. Written informed consent for RT-SWE was obtained from all eligible patients, who were healthy women aged between 19 and 52 y. Young's moduli of the breast tissue in the early follicular, late phase and luteal phase were compared. There were no significant differences in the mean, maximum and minimum elasticity values (Emean, Emax and Emin) and standard deviation (ESD). RT-SWE of glandular tissue revealed that ESD was increased in the early follicular phase compared with the luteal phase. Means ± SD of Emin, Emax and Emean in glandular tissue were 5.174 ± 2.138, 8.308 ± 3.166 and 6.593 ± 2.510, respectively, and in adipose tissue, 3.589 ± 2.083, 6.733 ± 3.522 and 4.857 ± 2.564, respectively. There were no significant differences in stiffness between glandular and adipose tissues throughout the menstrual cycle, but glandular tissue stiffness was lower in the luteal phase than in the early follicular phase. On the basis of these observations in normal healthy women, we believe we have obtained sufficient information to establish the baseline changes in human breast elasticity during the menstrual cycle. In the future, we intend to compare the elasticity values of healthy breast tissue with those of breast tissue affected by various pathologies. Our results reveal the significant potential of RT-SWE in the rapid and non-invasive clinical diagnosis of breast diseases, such as breast cancers. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Spontaneous calcium waves in Bergman glia increase with age and hypoxia and may reduce tissue oxygen

    DEFF Research Database (Denmark)

    Mathiesen, Claus; Brazhe, Alexey; Thomsen, Kirsten Joan

    2013-01-01

    Glial calcium (Ca(2+)) waves constitute a means to spread signals between glial cells and to neighboring neurons and blood vessels. These waves occur spontaneously in Bergmann glia (BG) of the mouse cerebellar cortex in vivo. Here, we tested three hypotheses: (1) aging and reduced blood oxygen sa...... activity during aging, as well as low resting brain oxygen tension, suggests a relationship between glial waves, brain energy homeostasis, and pathology.......Glial calcium (Ca(2+)) waves constitute a means to spread signals between glial cells and to neighboring neurons and blood vessels. These waves occur spontaneously in Bergmann glia (BG) of the mouse cerebellar cortex in vivo. Here, we tested three hypotheses: (1) aging and reduced blood oxygen...... saturation alters wave activity; (2) glial Ca(2+) waves change cerebral oxygen metabolism; and (3) neuronal and glial wave activity is correlated. We used two-photon microscopy in the cerebellar cortexes of adult (8- to 15-week-old) and aging (48- to 80-week-old) ketamine-anesthetized mice after bolus...

  14. Multiscale Vision Model Highlights Spontaneous Glial Calcium Waves Recorded by 2-Photon Imaging in Brain Tissue

    DEFF Research Database (Denmark)

    Brazhe, Alexey; Mathiesen, Claus; Lauritzen, Martin

    2013-01-01

    Intercellular glial calcium waves constitute a signaling pathway which can be visualized by fluorescence imaging of cytosolic Ca2+ changes. However, there is a lack of procedures for sensitive and reliable detection of calcium waves in noisy multiphoton imaging data. Here we extend multiscale...

  15. Right Ventricular Doppler Echocardiographic Study of Indeterminate Form of Chagas Disease

    Directory of Open Access Journals (Sweden)

    Rogério Gomes Furtado

    2015-03-01

    Full Text Available Background: Patients with indeterminate form of Chagas disease/cardiac normality (ICD/CN exhibited normal electrocardiograms and chest X-rays; however, more sophisticated tests detected some degree of morphological and functional changes in the heart. Objective: To assess the prevalence of systolic and diastolic dysfunction of the right ventricle (RV in patients with ICD/CN. Methods: This was a case–control and prevalence study. Using Doppler two-dimensional echocardiography (2D, 92 patients were assessed and divided into two groups: group I (normal, n = 31 and group II (ICD/CN, n = 61. Results: The prevalence of RV systolic dysfunction in patients in groups I and II was as follows: fractional area change (0.0% versus 0.6%, mobility of the tricuspid annulus (0.0% versus 0.0%, and S-wave tissue Doppler (6.4% versus 26.0%, p = 0.016. The prevalence of global disorders such as the right myocardial performance index using tissue Doppler (16.1% versus 27.8%, p = 0.099 and pulsed Doppler (61.3% versus 68%, p = 0.141 and diastolic disorders such as abnormal relaxation (0.0% versus 6.0%, pseudonormal pattern (0.0% versus 0.0%, and restrictive pattern (0.0% versus 0.0% was not statistically different between groups. Conclusion: The prevalence of RV systolic dysfunction was estimated to be 26% (S wave velocity compared with other variables, suggesting incipient changes in RV systolic function in the ICD/CN group.

  16. Exposure of zebra mussels to extracorporeal shock waves demonstrates formation of new mineralized tissue inside and outside the focus zone.

    Science.gov (United States)

    Sternecker, Katharina; Geist, Juergen; Beggel, Sebastian; Dietz-Laursonn, Kristin; de la Fuente, Matias; Frank, Hans-Georg; Furia, John P; Milz, Stefan; Schmitz, Christoph

    2018-04-03

    The success rate of extracorporeal shock wave therapy (ESWT) for fracture nonunions in human medicine (i.e., radiographic union at six months after ESWT) is only approximately 75%. Detailed knowledge regarding the underlying mechanisms that induce bio-calcification after ESWT is limited. We analyzed the biological response within mineralized tissue of a new invertebrate model organism, the zebra mussel Dreissena polymorpha , after exposure with extracorporeal shock waves (ESWs). Mussels were exposed to ESWs with positive energy density of 0.4 mJ/mm 2 (A) or were sham exposed (B). Detection of newly calcified tissue was performed by exposing the mussels to fluorescent markers. Two weeks later, the A-mussels showed a higher mean fluorescence signal intensity within the shell zone than the B-mussels (pmussels was independent of the size and position of the focal point of the ESWs. These data demonstrate that induction of bio-calcification after ESWT may not be restricted to the region of direct energy transfer of ESWs into calcified tissue. The results of the present study are of relevance for better understanding of the molecular and cellular mechanisms that induce formation of new mineralized tissue after ESWT. © 2018. Published by The Company of Biologists Ltd.

  17. Doppler-guided retrograde catheterization system

    Science.gov (United States)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  18. Suppression of Spiral Waves by Voltage Clamp Techniques in a Conductance-Based Cardiac Tissue Model

    International Nuclear Information System (INIS)

    Lian-Chun, Yu; Guo-Yong, Zhang; Yong, Chen; Jun, Ma

    2008-01-01

    A new control method is proposed to control the spatio-temporal dynamics in excitable media, which is described by the Morris–Lecar cells model. It is confirmed that successful suppression of spiral waves can be obtained by spatially clamping the membrane voltage of the excitable cells. The low voltage clamping induces breakup of spiral waves and the fragments are soon absorbed by low voltage obstacles, whereas the high voltage clamping generates travel waves that annihilate spiral waves through collision with them. However, each method has its shortcomings. Furthermore, a two-step method that combines both low and high voltage clamp techniques is then presented as a possible way of out this predicament. (cross-disciplinary physics and related areas of science and technology)

  19. Harmful effects of mobile phone waves on blood tissues of the human body

    OpenAIRE

    Kumar, Vijay; Ahmad, Mushtaq; Sharma, A. K.

    2013-01-01

      Abstract. Penetration of electromagnetic waves emitted by mobile phones into human skin and blood was studied. The transmitted waves from these mobile phones were exposed to the human body and were penetrated into the body where field was reduced exponentially with depth. As the reduction in field was due to absorption of power, specific absorption rate was calculated and compared with permissible limit given by International Commission on Non-ionizing Radiation Protection (ICNIRP) and Worl...

  20. Right heart function in impaired left ventricular diastolic function: 2D speckle tracking echocardiography-based and Doppler tissue imaging-based analysis of right atrial and ventricular function.

    Science.gov (United States)

    Brand, Anna; Bathe, Marny; Oertelt-Prigione, Sabine; Seeland, Ute; Rücke, Mirjam; Regitz-Zagrosek, Vera; Stangl, Karl; Knebel, Fabian; Stangl, Verena; Dreger, Henryk

    2018-01-01

    The aim of our study was to describe right atrial (RA) and right ventricular (RV) function, assessed by Doppler tissue imaging and 2D speckle tracking echocardiography (2DSTE), in women with signs of early impaired left ventricular diastolic function (DD). In a cross-sectional trial, standard parameters of diastolic and right heart function were investigated in 438 women of the Berlin Female Risk Evaluation (BEFRI) study. In a subset of women, average peak systolic RA strain (RAS), as well as the average peak systolic RV strain of the free wall (RVS free wall) and of all RV segments (average RV strain; RVS Avg), was analyzed using 2DSTE. Compared to women with normal diastolic function (DD0), RAS, RVS free wall and RVS Avg were significantly reduced in DD (43.1% ± 11.9%, -26.7% ± 5.6%, and -23.3% ± 3.5% in DD0; vs 35.1% ± 10.4%, -23.9% ± 5.5%, and -20.6% ± 3.8% in DD; P right heart function is significantly altered in DD. DTI as well as 2DSTE constitute sensitive echocardiographic tools that enable the diagnosis of impaired right heart mechanics in early-staged DD. © 2017 Wiley Periodicals, Inc.

  1. A quantitative analysis of microcirculation in sore-prone pressure areas on conventional and pressure relief hospital mattresses using laser Doppler flowmetry and tissue spectrophotometry.

    Science.gov (United States)

    Rothenberger, Jens; Krauss, Sabrina; Held, Manuel; Bender, Dominik; Schaller, Hans-Eberhard; Rahmanian-Schwarz, Afshin; Constantinescu, Mihai Adrian; Jaminet, Patrick

    2014-11-01

    Pressure ulcers are associated with severe impairment for the patients and high economic load. With this study we wanted to gain more insight to the skin perfusion dynamics due to external loading. Furthermore, we evaluated the effect of different types of pressure relief mattresses. A total of 25 healthy volunteers were enrolled in the study. Perfusion dynamics of the sacral and the heel area were assessed using the O2C-device, which combines a laser light, to determine blood flow, and white light to determine the relative amount of hemoglobin. Three mattresses were evaluated compared to a hard surface: a standard hospital foam mattress bed, a visco-elastic foam mattress, and an air-fluidized bed. In the heel area, only the air-fluidized bed was able to maintain the blood circulation (mean blood flow of 13.6 ± 6 versus 3.9 ± 3 AU and mean relative amount of hemoglobin of 44.0 ± 14 versus 32.7 ± 12 AU.) In the sacral area, all used mattresses revealed an improvement of blood circulation compared to the hard surface. The results of this study form a more precise pattern of perfusion changes due to external loading on various pressure relief mattresses. This knowledge may reduce the incidence of pressure ulcers and may be an influencing factor in pressure relief mattress selection. Copyright © 2014 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  2. Estimation of diastolic filling pressure with cardiac CT in comparison with echocardiography using tissue doppler imaging: Determination of optimal CT reconstruction parameters

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Sun; Suh, Jon; Lee, Heon [Soonchunhyang University Hospital Bucheon, Bucheon (Korea, Republic of); Lee, Bora [Dept. of Biostatistics, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of); Lee, Soo Jeong [Terarecon Korea, Seoul (Korea, Republic of); Jou, Sung Shick [Dept. of Radiology, Soonchunhyang University Hospital Cheonan, Cheonan (Korea, Republic of); Lim, Hyun Kyung [Dept. of Radiology, Soonchunhyang University Hospital Seoul, Seoul (Korea, Republic of)

    2017-08-01

    To determine the optimal CT image reconstruction parameters for the measurement of early transmitral peak velocity (E), early peak mitral septal tissue velocity (E′), and E / E′. Forty-six patients underwent simultaneous cardiac CT and echocardiography on the same day. Four CT datasets were reconstructed with a slice thickness/interval of 0.9/0.9 mm or 3/3 mm at 10 (10% RR-interval) or 20 (5% RR-interval) RR-intervals. The E was calculated by dividing the peak transmitral flow (mL/s) by the corresponding mitral valve area (cm{sup 2}). E′ was calculated from the changes in the left ventricular length per cardiac phase. E / E′ was then estimated and compared with that from echocardiography. For assessment of E / E′, CT and echocardiography were more strongly correlated (p < 0.05) with a slice thickness of 0.9 mm and 5% RR-interval (r = 0.77) than with 3 mm or 10% RR-interval. The diagnostic accuracy of predicting elevated filling pressure (E / E′ ≥ 13, n = 14) was better with a slice thickness of 0.9 mm and 5% RR-interval (87.0%) than with 0.9 mm and 10% RR-interval (71.7%) (p = 0.123) and significantly higher than that with a slice thickness of 3 mm with 5% (67.4%) and 10% RR-interval (63.0%), (p < 0.05), respectively. Data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval is superior to that with a slice thickness of 3 mm or 10% RR-interval in terms of the correlation of E / E′ between CT and echocardiography. Thin slices and frequent sampling also allow for more accurate prediction of elevated filling pressure.

  3. The effect of extracorporeal shock wave lithotripsy on kidney and adjacent tissue detected by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Saiko, Yasushi; Hirose, Tomonobu; Yoshida, Masahiko; Saito, Isao

    1995-01-01

    Etracorporeal shock wave lithotripsy (ESWL) using YACHIYODA SZ1 was performed on 12 patients with renal stones and the effect on the kidney and adjacent tissue was evaluated by magnetic resonance imaging(MRI) before and after treatment. Some changes were seen in 6 of the 12 (50%) patients; perirenal fluid collection in 2 of the 12 (16.7%) patients, subcapsular hematoma in 2 of the 12 (16.7%) patients, renal enlargement in 5 of the 12 (31.3%) patients, increased signal intensity in perirenal tissue in 6 of the 12 (50%) patients, and loss of the corticomedullary junction in 2 out of 9 patients (22%). These findings indicated fewer changes in the kidney after ESWL using YACHIYODA SZ1 than in the other reports. MRI is also concluded to be effective to detect the changes of the kidney after ESWL. (author)

  4. The effect of extracorporeal shock wave lithotripsy on kidney and adjacent tissue detected by magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Saiko, Yasushi; Hirose, Tomonobu; Yoshida, Masahiko; Saito, Isao [Tokyo Kyosai Hospital (Japan)

    1995-08-01

    Etracorporeal shock wave lithotripsy (ESWL) using YACHIYODA SZ1 was performed on 12 patients with renal stones and the effect on the kidney and adjacent tissue was evaluated by magnetic resonance imaging(MRI) before and after treatment. Some changes were seen in 6 of the 12 (50%) patients; perirenal fluid collection in 2 of the 12 (16.7%) patients, subcapsular hematoma in 2 of the 12 (16.7%) patients, renal enlargement in 5 of the 12 (31.3%) patients, increased signal intensity in perirenal tissue in 6 of the 12 (50%) patients, and loss of the corticomedullary junction in 2 out of 9 patients (22%). These findings indicated fewer changes in the kidney after ESWL using YACHIYODA SZ1 than in the other reports. MRI is also concluded to be effective to detect the changes of the kidney after ESWL. (author).

  5. Acoustic radiation force impulse elastography of the kidneys: is shear wave velocity affected by tissue fibrosis or renal blood flow?

    Science.gov (United States)

    Asano, Kenichiro; Ogata, Ai; Tanaka, Keiko; Ide, Yoko; Sankoda, Akiko; Kawakita, Chieko; Nishikawa, Mana; Ohmori, Kazuyoshi; Kinomura, Masaru; Shimada, Noriaki; Fukushima, Masaki

    2014-05-01

    The aim of this study was to identify the main influencing factor of the shear wave velocity (SWV) of the kidneys measured by acoustic radiation force impulse elastography. The SWV was measured in the kidneys of 14 healthy volunteers and 319 patients with chronic kidney disease. The estimated glomerular filtration rate was calculated by the serum creatinine concentration and age. As an indicator of arteriosclerosis of large vessels, the brachial-ankle pulse wave velocity was measured in 183 patients. Compared to the degree of interobserver and intraobserver deviation, a large variance of SWV values was observed in the kidneys of the patients with chronic kidney disease. Shear wave velocity values in the right and left kidneys of each patient correlated well, with high correlation coefficients (r = 0.580-0.732). The SWV decreased concurrently with a decline in the estimated glomerular filtration rate. A low SWV was obtained in patients with a high brachial-ankle pulse wave velocity. Despite progression of renal fibrosis in the advanced stages of chronic kidney disease, these results were in contrast to findings for chronic liver disease, in which progression of hepatic fibrosis results in an increase in the SWV. Considering that a high brachial-ankle pulse wave velocity represents the progression of arteriosclerosis in the large vessels, the reduction of elasticity succeeding diminution of blood flow was suspected to be the main influencing factor of the SWV in the kidneys. This study indicates that diminution of blood flow may affect SWV values in the kidneys more than the progression of tissue fibrosis. Future studies for reducing data variance are needed for effective use of acoustic radiation force impulse elastography in patients with chronic kidney disease.

  6. Spiral-wave dynamics in ionically realistic mathematical models for human ventricular tissue: the effects of periodic deformation.

    Science.gov (United States)

    Nayak, Alok R; Pandit, Rahul

    2014-01-01

    We carry out an extensive numerical study of the dynamics of spiral waves of electrical activation, in the presence of periodic deformation (PD) in two-dimensional simulation domains, in the biophysically realistic mathematical models of human ventricular tissue due to (a) ten-Tusscher and Panfilov (the TP06 model) and (b) ten-Tusscher, Noble, Noble, and Panfilov (the TNNP04 model). We first consider simulations in cable-type domains, in which we calculate the conduction velocity θ and the wavelength λ of a plane wave; we show that PD leads to a periodic, spatial modulation of θ and a temporally periodic modulation of λ; both these modulations depend on the amplitude and frequency of the PD. We then examine three types of initial conditions for both TP06 and TNNP04 models and show that the imposition of PD leads to a rich variety of spatiotemporal patterns in the transmembrane potential including states with a single rotating spiral (RS) wave, a spiral-turbulence (ST) state with a single meandering spiral, an ST state with multiple broken spirals, and a state SA in which all spirals are absorbed at the boundaries of our simulation domain. We find, for both TP06 and TNNP04 models, that spiral-wave dynamics depends sensitively on the amplitude and frequency of PD and the initial condition. We examine how these different types of spiral-wave states can be eliminated in the presence of PD by the application of low-amplitude pulses by square- and rectangular-mesh suppression techniques. We suggest specific experiments that can test the results of our simulations.

  7. Spiral-Wave Dynamics in Ionically Realistic MathematicalModels for Human Ventricular Tissue: The Effects of PeriodicDeformation

    Directory of Open Access Journals (Sweden)

    Alok Ranjan Nayak

    2014-06-01

    Full Text Available We carry out an extensive numerical study of the dynamics of spiral waves of electrical activation, in the presence of periodic deformation (PD in two-dimensional simulation domains, in the biophysically realistic mathematical models of human ventricular tissue due to (a ten-Tusscher and Panfilov (the TP06 model and (b ten-Tusscher, Noble, Noble, and Panfilov (theTNNP04 model. We first consider simulations in cable-type domains, in which we calculate the conduction velocity $CV$ andthe wavelength $lambda$ of a plane wave; we show that PD leads to a periodic, spatial modulation of $CV$ and a temporallyperiodic modulation of $lambda$; both these modulations depend on the amplitude and frequency of the PD. We then examine three types of initial conditions for both TP06 and TNNP04 models and show that the imposition of PD leads to a rich variety ofspatiotemporal patterns in the transmembrane potential including states with a single rotating spiral (RS wave, a spiral-turbulence (ST state with a single meandering spiral, an ST state with multiple broken spirals, and a state SA in which all spirals are absorbed at the boundaries of our simulation domain. We find, for both TP06 and TNNP04 models, that spiral-wave dynamics depends sensitively on the amplitude and frequency of PD and the initial condition. We examine how these different types of spiral-wave states can be eliminated in the presence of PD by the application of low-amplitude pulses on square and rectangular control meshes. We suggest specific experiments that can test the results of our simulations.

  8. Wave

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo

    2008-01-01

    Estimates for the amount of potential wave energy in the world range from 1-10 TW. The World Energy Council estimates that a potential 2TW of energy is available from the world’s oceans, which is the equivalent of twice the world’s electricity production. Whilst the recoverable resource is many...... times smaller it remains very high. For example, whilst there is enough potential wave power off the UK to supply the electricity demands several times over, the economically recoverable resource for the UK is estimated at 25% of current demand; a lot less, but a very substantial amount nonetheless....

  9. Numerical stud of glare spot phase Doppler anemometry

    OpenAIRE

    Hespel , Camille; Ren , Kuan Fang; Gréhan , Gérard; Onofri , Fabrice

    2008-01-01

    International audience; The phase Doppler anemometry has (PDA) been developed to measure simultaneously the velocity and the size of droplets. When the concentration of particles is high, tightly focused beams must be used, as in the dual burst PDA. The latter permits an access to the refractive index of the particle, but the effect of wave front curvature of the incident beams becomes evident. In this paper, we introduce a glare spot phase Doppler anemometry which uses two large beams. The i...

  10. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  11. Tissue

    Directory of Open Access Journals (Sweden)

    David Morrissey

    2012-01-01

    Full Text Available Purpose. In vivo gene therapy directed at tissues of mesenchymal origin could potentially augment healing. We aimed to assess the duration and magnitude of transene expression in vivo in mice and ex vivo in human tissues. Methods. Using bioluminescence imaging, plasmid and adenoviral vector-based transgene expression in murine quadriceps in vivo was examined. Temporal control was assessed using a doxycycline-inducible system. An ex vivo model was developed and optimised using murine tissue, and applied in ex vivo human tissue. Results. In vivo plasmid-based transgene expression did not silence in murine muscle, unlike in liver. Although maximum luciferase expression was higher in muscle with adenoviral delivery compared with plasmid, expression reduced over time. The inducible promoter cassette successfully regulated gene expression with maximum levels a factor of 11 greater than baseline. Expression was re-induced to a similar level on a temporal basis. Luciferase expression was readily detected ex vivo in human muscle and tendon. Conclusions. Plasmid constructs resulted in long-term in vivo gene expression in skeletal muscle, in a controllable fashion utilising an inducible promoter in combination with oral agents. Successful plasmid gene transfection in human ex vivo mesenchymal tissue was demonstrated for the first time.

  12. Effect of Graphite Concentration on Shear-Wave Speed in Gelatin-Based Tissue-Mimicking Phantoms

    Science.gov (United States)

    Anderson, Pamela G.; Rouze, Ned C.; Palmeri, Mark L.

    2011-01-01

    Elasticity-based imaging modalities are becoming popular diagnostic tools in clinical practice. Gelatin-based, tissue mimicking phantoms that contain graphite as the acoustic scattering material are commonly used in testing and validating elasticity-imaging methods to quantify tissue stiffness. The gelatin bloom strength and concentration are used to control phantom stiffness. While it is known that graphite concentration can be modulated to control acoustic attenuation, the impact of graphite concentrationon phantom elasticity has not been characterized in these gelatin phantoms. This work investigates the impact of graphite concentration on phantom shear stiffness as characterized by shear-wave speed measurements using impulsive acoustic-radiation-force excitations. Phantom shear-wave speed increased by 0.83 (m/s)/(dB/(cm MHz)) when increasing the attenuation coefficient slope of the phantom material through increasing graphite concentration. Therefore, gelatin-phantom stiffness can be affected by the conventional ways that attenuation is modulated through graphite concentration in these phantoms. PMID:21710828

  13. Coherent Detection in Laser Doppler Velocimeters

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner

    1974-01-01

    , but intelligible particle picture of electromagnetic waves. The analysis is carried out with special emphasis on the heterodyning process in the laser Doppler velocimeter (LDV) because the main purpose of this article is to provide a better understanding of this instrument. An aid for this purpose......The possibility of heterodyning between electromagnetic waves scattered by particles separated in space is explained from a classical point of view and from a quantum mechanical point of view. The last description being carried out using only the Heisenberg uncertainty principle and a rather coarse...

  14. The phenomenon of Doppler

    International Nuclear Information System (INIS)

    Stoll, I.; Seidlerova, I.; Schwippel, J.; Poss, O.; Solc, M.

    1992-01-01

    The book is devoted to the life and work of Christian Doppler and particularly to his links to Prague and to the Slovak town of Banska Stiavnica. Many historical facts concerning Doppler's activities as well as the history of physics and astronomy are collected. Information is also presented about the Czech Technical University, the Society of Czechoslovak Mathematicians and Physicists, the Czechoslovak Astronomical Society, the Czechoslovak Spectroscopic Society and the Czechoslovak Society for the History of Science and Technology. The publication is amply supplemented with historical pictorial material (M.D.). 92 figs., 82 refs

  15. Doppler ion program description

    International Nuclear Information System (INIS)

    Henline, P.

    1980-12-01

    The Doppler spectrometer is a conventional Czerny-Turner grating spectrometer with a 1024 channel multiple detector. Light is dispersed across the detector, and its output yields a spectrum covering approximately 200 A. The width of the spectral peak is directly proportional to the temperature of the emitting ions, and determination of the impurity ion temperature allows one to infer the plasma ion temperature. The Doppler ion software system developed at General Atomic uses a TRACOR Northern 1710-31 and an LSI-11/2. The exact configuration of Doublet III is different from TRACOR Northern systems at other facilities

  16. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  17. In vivo effects of focused shock waves on tumor tissue visualized by fluorescence staining techniques

    Czech Academy of Sciences Publication Activity Database

    Lukeš, Petr; Zeman, J.; Horák, Vratislav; Hoffer, Petr; Poučková, P.; Holubová, Monika; Hosseini, S.H.R.; Akiyama, H.; Šunka, Pavel; Beneš, J.

    2015-01-01

    Roč. 103, June (2015), s. 103-110 ISSN 1567-5394 R&D Projects: GA MŠk ED2.1.00/03.0124 Grant - others:Rada Programu interní podpory projektů mezinárodní spolupráce AV ČR(CZ) M100431203 Program:M Institutional support: RVO:61389021 ; RVO:67985904 Keywords : Electrical discharge * Shock waves * Tumor damage * Necrosis * Apoptosis Subject RIV: BO - Biophysics Impact factor: 3.556, year: 2015 http://dx.doi.org/10.1016/j.bioelechem.2014.08.019

  18. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  19. Doppler-musical instrument

    International Nuclear Information System (INIS)

    Sato, T.J.; Watanabe, N.

    2001-01-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 μeV, even when the ultra-high energy resolution of ΔE∼0.03 μeV is attained. (author)

  20. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  1. Numerical simulation of ultrasound-thermotherapy combining nonlinear wave propagation with broadband soft-tissue absorption.

    Science.gov (United States)

    Ginter, S

    2000-07-01

    Ultrasound (US) thermotherapy is used to treat tumours, located deep in human tissue, by heat. It features by the application of high intensity focused ultrasound (HIFU), high local temperatures of about 90 degrees C and short treating time of a few seconds. Dosage of the therapy remains a problem. To get it under control, one has to know the heat source, i.e. the amount of absorbed US power, which shows nonlinear influences. Therefore, accurate simulations are essential. In this paper, an improved simulation model is introduced which enables accurate investigations of US thermotherapy. It combines nonlinear US propagation effects, which lead to generation of higher harmonics, with a broadband frequency-power law absorption typical for soft tissue. Only the combination of both provides a reliable calculation of the generated heat. Simulations show the influence of nonlinearities and broadband damping for different source signals on the absorbed US power density distribution.

  2. A clutter removal method for the Doppler ultrasound signal based on a nonlinear diffusion equation

    International Nuclear Information System (INIS)

    Li Peng; Xin Pengcheng; Bian Zhengzhong; Yu Gang

    2008-01-01

    Strong clutter components produced by stationary and slow-moving tissue structures render the lower frequency part of the spectrogram useless and degrade the accuracy of clinical ultrasound indices. An adaptive method based on the nonlinear forward-and-backward diffusion equation (FAB-DE) is proposed to remove strong clutter components from the contaminated Doppler signal. The clutter signal is extracted first by the FAB-DE accurately, in which the nonlinear diffusion coefficient function of the FAB-DE locally adjusts according to signal features and the diffusion adaptively switches between forward and backward mode. The present method has been validated by simulated and realistic pulse wave Doppler signals, and compared with the conventional high pass filter and the matching pursuit method. The simulation results, including spectrogram, mean velocity error, standard deviation of mean velocity and signal-to-clutter ratio of a decontaminated signal, demonstrate that the present FAB-DE method can remove clutter sufficiently and retain more low blood components simultaneously as compared with the other two methods. Results of the realistic Doppler blood signal, including spectrogram and low-frequency part of the spectrum, support the conclusion drawn from simulation cases

  3. Acoustic radiation force impulse imaging with Virtual Touch™ tissue quantification: mean shear wave velocity of malignant and benign breast masses.

    Science.gov (United States)

    Wojcinski, Sebastian; Brandhorst, Kathrin; Sadigh, Gelareh; Hillemanns, Peter; Degenhardt, Friedrich

    2013-01-01

    Acoustic radiation force impulse imaging (ARFI) with Virtual Touch™ tissue quantification (VTTQ) enables the determination of shear wave velocity (SWV) in meters per second (m/s). The aim of our study was to describe the mean SWV in normal breast tissue and various breast masses. We performed measurements of SWV with ARFI VTTQ in 145 breast masses (57 malignant, 88 benign) and in the adjacent breast parenchyma and adipose tissue. The mean SWV as well as the rate of successful measurements were analyzed. The difference between adipose tissue and parenchyma was statistically significant (3.05 versus 3.65 m/s) (P breast masses, numerous measurements exceeded the upper limit of possible measurement (≥9.10 m/s, indicated as "X.XX m/s"). Nevertheless, the difference between the malignant and benign masses was statistically significant (8.38 ± 1.99 m/s versus 5.39 ± 2.95 m/s) (P < 0.001). The best diagnostic accuracy (75.9%) was achieved when the cutoff point for malignancy was set to 9.10 m/s in ARFI VTTQ. This implies that the SWV was regarded as suspicious when the upper limit of possible measurement was exceeded and the machine returned the value X.XX m/s. In conclusion, ARFI VTTQ is a feasible method for measurement of SWV in a region of interest. Furthermore, we propose the event of a highly elevated SWV as a significant criterion for malignancy. However, the method is technically not yet fully developed, and the problem of unsuccessful measurements must still be solved.

  4. Accuracy of real-time shear wave elastography in the assessment of normal liver tissue in the guinea pig (cavia porcellus).

    Science.gov (United States)

    Glińska-Suchocka, K; Kubiak, K; Spużak, J; Jankowski, M; Borusewicz, P

    2017-03-28

    Shear wave elastography is a novel technique enabling real-time measurement of the elasticity of liver tissue. The color map is superimposed on the classic ultrasound image of the assessed tissue, which enables a precise evaluation of the stiffness of the liver tissue. The aim of the study was to assess the stiffness of normal liver tissue in the guinea pig using shear wave elastography. The study was carried out on 36 guinea pigs using the SuperSonic Imagine Aixplorer scanner, and a 1 to 6 MH convex SC6-1 transducer. An ultrasound guided Try-Cut liver core needle biopsy was carried out in all the studied animals and the collected samples were examined to exclude pathological lesions. The mean liver tissue stiffness ranged from 0.89 to 5.40 kPa. We found that shear wave elastography is an easy, non-invasive technique that can be used to assess the stiffness of liver tissue. The obtained results can be used in future studies to assess the types and changes of liver tissue in the course of various types of liver disease.

  5. Assessment of the Effectiveness of Extracorporeal Shock Wave Therapy (ESWT) For Soft Tissue Injuries (ASSERT): An Online Database Protocol.

    Science.gov (United States)

    Maffulli, G; Hemmings, S; Maffulli, N

    2014-09-01

    Soft tissue injuries and tendinopathies account for large numbers of chronic musculoskeletal disorders. Extracorporeal shockwave therapy (ESWT) is popular, and effective in the management of chronic tendon conditions in the elbow, shoulder, and pain at and around the heel. Ethical approval was granted from the South East London Research Ethics Committee to implement a database for the Assessment of Effectiveness of Extracorporeal Shock Wave Therapy for Soft Tissue Injuries (ASSERT) to prospectively collect information on the effectiveness of ESWT across the UK. All participants will give informed consent. All clinicians follow a standardised method of administration of the ESWT. The primary outcome measures are validated outcome measures specific to the condition being treated. A Visual Analogue Score for pain and the EuroQol will be completed alongside the condition specific outcome tool at baseline, 3, 6, 12 and 24 months post treatment. The development of the ASSERT database will enable the evaluation of the effectiveness of ESWT for patients suffering from chronic conditions (plantar fasciopathy, tennis elbow, Achilles tendinopathy, greater trochanter pain syndrome and patellar tendinopathy). The results will aid the clinicians in the decision making process when managing these patients.

  6. Spiral-wave dynamics in a mathematical model of human ventricular tissue with myocytes and Purkinje fibers.

    Science.gov (United States)

    Nayak, Alok Ranjan; Panfilov, A V; Pandit, Rahul

    2017-02-01

    We present systematic numerical studies of the possible effects of the coupling of human endocardial and Purkinje cells at cellular and two-dimensional tissue levels. We find that the autorhythmic-activity frequency of the Purkinje cell in a composite decreases with an increase in the coupling strength; this can even eliminate the autorhythmicity. We observe a delay between the beginning of the action potentials of endocardial and Purkinje cells in a composite; such a delay increases as we decrease the diffusive coupling, and eventually a failure of transmission occurs. An increase in the diffusive coupling decreases the slope of the action-potential-duration-restitution curve of an endocardial cell in a composite. By using a minimal model for the Purkinje network, in which we have a two-dimensional, bilayer tissue, with a layer of Purkinje cells on top of a layer of endocardial cells, we can stabilize spiral-wave turbulence; however, for a sparse distribution of Purkinje-ventricular junctions, at which these two layers are coupled, we can also obtain additional focal activity and many complex transient regimes. We also present additional effects resulting from the coupling of Purkinje and endocardial layers and discuss the relation of our results to the studies performed in anatomically accurate models of the Purkinje network.

  7. From single cilia to collective waves in human airway ciliated tissues

    Science.gov (United States)

    Cicuta, Pietro; Chioccioli, Maurizio; Feriani, Luigi; Pellicciotta, Nicola; Kotar, Jurij

    I will present experimental results on activity of motile cilia on various scales: from waveforms on individual cilia to the synchronised motion in cilia carpets of airway cells. Model synthetic experiments have given us an understanding of how cilia could couple with each other through forces transmitted by the fluid, and thus coordinate to beat into well organized waves (previous work is reviewed in Annu. Rev. Condens. Matter Phys. 7, 1-26 (2016)). Working with live imaging of airway human cells at the different scales, we can now test whether the biological system satisfies the ``simple'' behavior expected of the fluid flow coupling, or if other factors of mechanical forces transmission need to be accounted for. In general being able to link from the scale of molecular biological activity up to the phenomenology of collective dynamics requires to understand the relevant physical mechanism. This understanding then allows informed diagnostics (and perhaps therapeutic) approaches to a variety of diseases where mucociliary clearance in the airways is compromised. We have started exploring particularly cystic fibrosis, where the rheological properties of the mucus are affected and prevent efficient cilia synchronization. ERC Grant HydroSync.

  8. Doppler-musical instrument

    Energy Technology Data Exchange (ETDEWEB)

    Sato, T.J. [National Research Institute for Metals, Tsukuba, Ibaraki (Japan); Watanabe, N. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment; Shibata, K. [Institute for Materials Research, Tohoku Univ., Sendai, Miyagi (Japan)

    2001-03-01

    We propose a possible ultra-high energy resolution backscattering spectrometer optimized to spallation neutron source. A combination of multi monochromator crystal and Doppler drive provides considerable neutron flux, together with the reasonable energy range -30 < E < 30 {mu}eV, even when the ultra-high energy resolution of {delta}E{approx}0.03 {mu}eV is attained. (author)

  9. Explanation of the Inverse Doppler Effect Observed in Nonlinear Transmission Lines

    International Nuclear Information System (INIS)

    Kozyrev, Alexander B.; Weide, Daniel W. van der

    2005-01-01

    The theory of the inverse Doppler effect recently observed in magnetic nonlinear transmission lines is developed. We explain the crucial role of the backward spatial harmonic in the occurrence of an inverse Doppler effect and draw analogies of the magnetic nonlinear transmission line to the backward wave oscillator

  10. DOPPLER SIGNATURES OF THE ATMOSPHERIC CIRCULATION ON HOT JUPITERS

    International Nuclear Information System (INIS)

    Showman, Adam P.; Lewis, Nikole K.; Fortney, Jonathan J.; Shabram, Megan

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation—and Doppler signature—of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blueshifted and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps these waves and inhibits jet formation. As a result, this second regime exhibits a circulation dominated by high-altitude, day-to-night airflow, leading to a predominantly blueshifted Doppler signature during transit. We present state-of-the-art circulation models including non-gray radiative transfer to quantify this regime shift and the resulting Doppler signatures; these models suggest that cool planets like GJ 436b lie in the first regime, HD 189733b is transitional, while planets hotter than HD 209458b lie in the second regime. Moreover, we show how the amplitude of the Doppler shifts constrains the strength of frictional drag in the upper atmospheres of hot Jupiters. If due to winds, the ∼2 km s –1 blueshift inferred on HD 209458b may require drag time constants as short as 10 4 -10 6 s, possibly the result of Lorentz-force braking on this planet's hot dayside.

  11. Acoustic radiation force impulse imaging with Virtual Touch™ tissue quantification: mean shear wave velocity of malignant and benign breast masses

    Directory of Open Access Journals (Sweden)

    Wojcinski S

    2013-09-01

    Full Text Available Sebastian Wojcinski,1 Kathrin Brandhorst,2 Gelareh Sadigh,3 Peter Hillemanns,1 Friedrich Degenhardt2 1Department of Obstetrics and Gynecology, Hannover Medical School, Hannover, Germany; 2Department of Obstetrics and Gynecology, Franziskus Hospital, Bielefeld, Germany; 3Department of Radiology, Emory University, Atlanta, GA, USA Abstract: Acoustic radiation force impulse imaging (ARFI with Virtual Touch™ tissue quantification (VTTQ enables the determination of shear wave velocity (SWV in meters per second (m/s. The aim of our study was to describe the mean SWV in normal breast tissue and various breast masses. We performed measurements of SWV with ARFI VTTQ in 145 breast masses (57 malignant, 88 benign and in the adjacent breast parenchyma and adipose tissue. The mean SWV as well as the rate of successful measurements were analyzed. The difference between adipose tissue and parenchyma was statistically significant (3.05 versus 3.65 m/s (P < 0.001. Focusing on breast masses, numerous measurements exceeded the upper limit of possible measurement (≥9.10 m/s, indicated as "X.XX m/s". Nevertheless, the difference between the malignant and benign masses was statistically significant (8.38 ± 1.99 m/s versus 5.39 ± 2.95 m/s (P < 0.001. The best diagnostic accuracy (75.9% was achieved when the cutoff point for malignancy was set to 9.10 m/s in ARFI VTTQ. This implies that the SWV was regarded as suspicious when the upper limit of possible measurement was exceeded and the machine returned the value X.XX m/s. In conclusion, ARFI VTTQ is a feasible method for measurement of SWV in a region of interest. Furthermore, we propose the event of a highly elevated SWV as a significant criterion for malignancy. However, the method is technically not yet fully developed, and the problem of unsuccessful measurements must still be solved. Keywords: ARFI VTTQ, elastography, ultrasound, breast imaging

  12. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  13. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  14. Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.

    Science.gov (United States)

    Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P

    1995-01-01

    Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.

  15. Attraction and repulsion of spiral waves by inhomogeneity of conduction anisotropy--a model of spiral wave interaction with electrical remodeling of heart tissue.

    Science.gov (United States)

    Kuklik, Pawel; Sanders, Prashanthan; Szumowski, Lukasz; Żebrowski, Jan J

    2013-01-01

    Various forms of heart disease are associated with remodeling of the heart muscle, which results in a perturbation of cell-to-cell electrical coupling. These perturbations may alter the trajectory of spiral wave drift in the heart muscle. We investigate the effect of spatially extended inhomogeneity of transverse cell coupling on the spiral wave trajectory using a simple active media model. The spiral wave was either attracted or repelled from the center of inhomogeneity as a function of cell excitability and gradient of the cell coupling. High levels of excitability resulted in an attraction of the wave to the center of inhomogeneity, whereas low levels resulted in an escape and termination of the spiral wave. The spiral wave drift velocity was related to the gradient of the coupling and the initial position of the wave. In a diseased heart, a region of altered transverse coupling corresponds with local gap junction remodeling that may be responsible for stabilization-destabilization of spiral waves and hence reflect potentially important targets in the treatment of heart arrhythmias.

  16. Comparison of peritumoral stromal tissue stiffness obtained by shear wave elastography between benign and malignant breast lesions.

    Science.gov (United States)

    Park, Hye Sun; Shin, Hee Jung; Shin, Ki Chang; Cha, Joo Hee; Chae, Eun Young; Choi, Woo Jung; Kim, Hak Hee

    2018-01-01

    Background Aggressive breast cancers produce abnormal peritumoral stiff areas, which can differ between benign and malignant lesions and between different subtypes of breast cancer. Purpose To compare the tissue stiffness of the inner tumor, tumor border, and peritumoral stroma (PS) between benign and malignant breast masses by shear wave elastography (SWE). Material and Methods We enrolled 133 consecutive patients who underwent preoperative SWE. Using OsiriX commercial software, we generated multiple 2-mm regions of interest (ROIs) in a linear arrangement on the inner tumor, tumor border, and PS. We obtained the mean elasticity value (E mean ) of each ROI, and compared the E mean between benign and malignant tumors. Odds ratios (ORs) for prediction of malignancy were calculated. Subgroup analyses were performed among tumor subtypes. Results There were 85 malignant and 48 benign masses. The E mean of the tumor border and PS were significantly different between benign and malignant masses ( P benign and malignant masses. Malignant masses with a stiff rim were larger in size and associated with more aggressive pathologic subtypes.

  17. Doppler velocity measurements from large and small arteries of mice

    Science.gov (United States)

    Reddy, Anilkumar K.; Madala, Sridhar; Entman, Mark L.; Michael, Lloyd H.; Taffet, George E.

    2011-01-01

    With the growth of genetic engineering, mice have become increasingly common as models of human diseases, and this has stimulated the development of techniques to assess the murine cardiovascular system. Our group has developed nonimaging and dedicated Doppler techniques for measuring blood velocity in the large and small peripheral arteries of anesthetized mice. We translated technology originally designed for human vessels for use in smaller mouse vessels at higher heart rates by using higher ultrasonic frequencies, smaller transducers, and higher-speed signal processing. With these methods one can measure cardiac filling and ejection velocities, velocity pulse arrival times for determining pulse wave velocity, peripheral blood velocity and vessel wall motion waveforms, jet velocities for the calculation of the pressure drop across stenoses, and left main coronary velocity for the estimation of coronary flow reserve. These noninvasive methods are convenient and easy to apply, but care must be taken in interpreting measurements due to Doppler sample volume size and angle of incidence. Doppler methods have been used to characterize and evaluate numerous cardiovascular phenotypes in mice and have been particularly useful in evaluating the cardiac and vascular remodeling that occur following transverse aortic constriction. Although duplex ultrasonic echo-Doppler instruments are being applied to mice, dedicated Doppler systems are more suitable for some applications. The magnitudes and waveforms of blood velocities from both cardiac and peripheral sites are similar in mice and humans, such that much of what is learned using Doppler technology in mice may be translated back to humans. PMID:21572013

  18. Comparative analysis of pulsed doppler ultrasonography of portal vein vs indirect photography

    International Nuclear Information System (INIS)

    Chang, Jae Chun; Kwon, Huck Po; Hwang, Mi Soo; Kim, Sun Youn; Park, Bok Hwan; Lee, Hyun Ju; Kim, Hong Jin

    1990-01-01

    There are some limitation of interpretation in indirect photography via superior mesenteric artery. In order to supplement and predict indirect photography, we compared indirect photographic findings with pulsed doppler flowmetry in 38 hepatobiliary patients, and the results were as follow: 1. In case of normal main portal vein(MPV) filling, Pulsed Doppler always showed antegrade, continuous parabolic wave form and cases of abnormal MPV filling, showed unusual wave form and flow direction. 2. In normal filling case of proximal right portal vein, Pulsed Doppler almost showed normal continuous parabolic wave form but in normal filling cases of proximal left portal vein, occasionally showed undulating wave form. 3. In each side proximal portal vein abnormal filling case, we could observe abnormal doppler wave form and could obtain additional information using doppler wave form. 4. Mean portal flow velocity was significantly increased in higher photography grade(p=0.01) and congestion index was significantly decreased in higher photography grade(p=0.01). 5. We concluded that doppler ultrasonography could supplement incomplete indirect photography

  19. Principles of doppler tomography

    International Nuclear Information System (INIS)

    Juhlin, P.

    1992-08-01

    This paper shows how the radon transform can be used to determine vector fields. A scheme to determine the velocity field of a moving fluid by measurements with a continuous doppler signal is suggested. When the flow is confined to a bounded domain, as is the case in most applications, it can be uniquely decomposed into one gradiental and one rotational part. The former vanishes if the fluid is incompressible and source-free, and the latter can be completely reconstructed by the methods proposed in this paper if the domain is simply connected. Special attention is paid to laminar flow in a long cylindrical vessel with circular cross-section. Under such conditions the flow profile becomes parabolic, which makes the vessel recognizable as a typical 'N-shaped' pattern in an image describing the rotation of the velocity field. The vessel yields the same doppler tomographic pattern, no matter how it is sectioned. The ideas presented should be applicable also when studying the flow in blood vessels, even if the flow profile in these is not quite parabolic. The discrepancies only make the 'N-shape' somewhat distorted

  20. Feasibility of UltraFast Doppler in Post-operative Evaluation of Hepatic Artery in Recipients following Liver Transplantation.

    Science.gov (United States)

    Kim, Se-Young; Kim, Kyoung Won; Choi, Sang Hyun; Kwon, Jae Hyun; Song, Gi-Won; Kwon, Heon-Ju; Yun, Young Ju; Lee, Jeongjin; Lee, Sung-Gyu

    2017-11-01

    To determine the feasibility of using UltraFast Doppler in post-operative evaluation of the hepatic artery (HA) after liver transplantation (LT), we evaluated 283 simultaneous conventional and UltraFast Doppler sessions in 126 recipients over a 2-mo period after LT, using an Aixplorer scanner The Doppler indexes of the HA (peak systolic velocity [PSV], end-diastolic velocity [EDV], resistive index [RI] and systolic acceleration time [SAT]) by retrospective analysis of retrieved waves from UltraFast Doppler clips were compared with those obtained by conventional spectral Doppler. Correlation, performance in diagnosing the pathologic wave, examination time and reproducibility were evaluated. The PSV, EDV, RI and SAT of spectral and UltraFast Doppler measurements exhibited excellent correlation with favorable diagnostic performance. During the bedside examination, the mean time spent for UltraFast clip storing was significantly shorter than that for conventional Doppler US measurements. Both conventional and UltraFast Doppler exhibited good to excellent inter-analysis consistency. In conclusion, compared with conventional spectral Doppler, UltraFast Doppler values correlated excellently and yielded acceptable pathologic wave diagnostic performance with reduced examination time at the bedside and excellent reproducibility. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  1. Doppler color flow mapping of peripheral vessels: Comparison of angiodynography with conventional duplex US

    International Nuclear Information System (INIS)

    Merritt, C.R.B.; Bluth, E.I.; Sullivan, M.A.

    1986-01-01

    A new Doppler color flow imager was compared to duplex US in the evaluation of carotid and peripheral vessels in 50 patients. A 7.5-MHz transducer permitted simultaneous high-resolution real-time imaging of Doppler flow and tissue. The system was found to have excellent image quality and Doppler sensitivity. Flow characteristics and velocity measurements obtained with this system correlated well with those obtained using the duplex scanner and were obtained more quickly than with the conventional system, allowing more complete assessment of flow characteristics. Color Doppler flow imaging appears to be an extremely promising method for the rapid and effective evaluation of peripheral vascular flow

  2. Deconvoluting double Doppler spectra

    International Nuclear Information System (INIS)

    Ho, K.F.; Beling, C.D.; Fung, S.; Chan, K.L.; Tang, H.W.

    2001-01-01

    The successful deconvolution of data from double Doppler broadening of annihilation radiation (D-DBAR) spectroscopy is a promising area of endeavour aimed at producing momentum distributions of a quality comparable to those of the angular correlation technique. The deconvolution procedure we test in the present study is the constrained generalized least square method. Trials with computer simulated DDBAR spectra are generated and deconvoluted in order to find the best form of regularizer and the regularization parameter. For these trials the Neumann (reflective) boundary condition is used to give a single matrix operation in Fourier space. Experimental D-DBAR spectra are also subject to the same type of deconvolution after having carried out a background subtraction and using a symmetrize resolution function obtained from an 85 Sr source with wide coincidence windows. (orig.)

  3. Adaptive Spectral Doppler Estimation

    DEFF Research Database (Denmark)

    Gran, Fredrik; Jakobsson, Andreas; Jensen, Jørgen Arendt

    2009-01-01

    . The methods can also provide better quality of the estimated power spectral density (PSD) of the blood signal. Adaptive spectral estimation techniques are known to pro- vide good spectral resolution and contrast even when the ob- servation window is very short. The 2 adaptive techniques are tested......In this paper, 2 adaptive spectral estimation techniques are analyzed for spectral Doppler ultrasound. The purpose is to minimize the observation window needed to estimate the spectrogram to provide a better temporal resolution and gain more flexibility when designing the data acquisition sequence...... and compared with the averaged periodogram (Welch’s method). The blood power spectral capon (BPC) method is based on a standard minimum variance technique adapted to account for both averaging over slow-time and depth. The blood amplitude and phase estimation technique (BAPES) is based on finding a set...

  4. Defocused low-energy shock wave activates adipose tissue-derived stem cells in vitro via multiple signaling pathways.

    Science.gov (United States)

    Xu, Lina; Zhao, Yong; Wang, Muwen; Song, Wei; Li, Bo; Liu, Wei; Jin, Xunbo; Zhang, Haiyang

    2016-12-01

    We found defocused low-energy shock wave (DLSW) could be applied in regenerative medicine by activating mesenchymal stromal cells. However, the possible signaling pathways that participated in this process remain unknown. In the present study, DLSW was applied in cultured rat adipose tissue-derived stem cells (ADSCs) to explore its effect on ADSCs and the activated signaling pathways. After treating with DLSW, the cellular morphology and cytoskeleton of ADSCs were observed. The secretions of ADSCs were detected. The expressions of ADSC surface antigens were analyzed using flow cytometry. The expressions of proliferating cell nuclear antigen and Ki67 were analyzed using western blot. The expression of CXCR2 and the migrations of ADSCs in vitro and in vivo were detected. The phosphorylation of selected signaling pathways with or without inhibitors was also detected. DLSW did not change the morphology and phenotype of ADSCs, and could promote the secretion, proliferation and migration of ADSCs. The phosphorylation levels were significantly higher in mitogen-activated protein kinases (MAPK) pathway, phosphoinositide 3-kinase (PI-3K)/AKT pathway and nuclear factor-kappa B (NF-κB) signaling pathway but not in Janus kinase/signal transducer and activator of transcription (JAK/STAT) pathway. Furthermore, ADSCs were not activated by DLSW after adding the inhibitors of these pathways simultaneously. Our results demonstrated for the first time that DLSW could activate ADSCs through MAPK, PI-3K/AKT and NF-κB signaling pathways. Combination of DLSW and agonists targeting these pathways might improve the efficacy of ADSCs in regenerative medicine in the future. Copyright © 2016 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.

  5. Detection of gravitational radiation by the Doppler tracking of spacecraft

    International Nuclear Information System (INIS)

    Mashhoon, B.

    1979-01-01

    It has been suggested that the residual Doppler shift in the precision electromagnetic tracking of spacecraft be used to search for gravitational radiation that may be incident on the Earth-spacecraft system. The influence of a gravitational wave on the Doppler shift is calculated, and it is found that the residual shift is dominated by two terms: one is due to the passage of electromagnetic waves through the gravitational radiation field, and the other depends on the change in the relative velocity of the Earth and the spacecraft caused by the external wave. A detailed analysis is given of the influence of gravitational radiation on a binary system with an orbital size small compared to the wavelength of the incident radiation. It is shown that, as a consequence of the interaction with the external wave, the system makes a transition from one Keplerian orbit into another which, in general, has a different energy and angular momentum. It is therefore proposed to search for such effects in the solar system. Observations of the orbit of an artificial Earth satellite, the lunar orbit, and especially the planetary orbits offer exciting possibilities for the detection of gravitational waves of various wavelengths. From the results of the lunar laser ranging experiment and the range measurement to Mars, certain interesting limits may be established on the frequency of incidence of gravitational waves of a given flux on the Earth-Moon and the Earth-Mars systems. This is followed by a brief and preliminary analysis of the possibility of detecting gravitational radiation by measuring a residual secular Doppler shift in the satellite-to-satellite Doppler tracking of two counterorbiting drag-free spacecraft around the Earth as in the Van Patten-Everitt experiment

  6. Doppler ultrasound imaging techniques for assessment of synovial inflammation

    Directory of Open Access Journals (Sweden)

    Filippucci E

    2013-09-01

    Full Text Available Emilio Filippucci,1 Fausto Salaffi,1 Marina Carotti,2 Walter Grassi1 1Rheumatology Department, Polytechnic University of the Marche, Ancona, Italy; 2Department of Radiology, Polytechnic University of the Marche, Ancona, Italy Abstract: Ultrasound is an evolving technique, and the rapid progress made in ultrasound technology over the past ten years has dramatically increased its range of applications in rheumatology. One of the most exciting advances is the use of Doppler ultrasound imaging in the assessment of blood flow abnormalities at the synovial tissue level in patients with chronic inflammatory arthritis. This review describes the Doppler techniques available and their main applications in patients with inflammatory arthritis, discusses the evidence supporting their use, and outlines the latest advances in hardware and software. Spectral, color, and power Doppler allow sensitive assessment of vascular abnormalities at the synovial tissue level. Use of contrast agents enhances visualization of the small synovial vessels using color or power Doppler ultrasound and allows for accurate characterization of the rheumatoid pannus. Doppler techniques represent a unique method for assessment of synovial inflammation, showing blood flow characteristics in real time. They are safe, noninvasive, cost-effective, and have high sensitivity in revealing and monitoring synovitis. However, several questions still need to be answered. In the near future, the Doppler techniques described here, together with upcoming hardware and software facilities, will be investigated further and a consensus will be reached on their feasibility and appropriate use in daily rheumatologic practice. Keywords: power and color Doppler techniques, ultrasound, contrast media, synovitis, rheumatoid arthritis

  7. 3D atom microscopy in the presence of Doppler shift

    Science.gov (United States)

    Rahmatullah; Chuang, You-Lin; Lee, Ray-Kuang; Qamar, Sajid

    2018-03-01

    The interaction of hot atoms with laser fields produces a Doppler shift, which can severely affect the precise spatial measurement of an atom. We suggest an experimentally realizable scheme to address this issue in the three-dimensional position measurement of a single atom in vapors of rubidium atoms. A three-level Λ-type atom-field configuration is considered where a moving atom interacts with three orthogonal standing-wave laser fields and spatial information of the atom in 3D space is obtained via an upper-level population using a weak probe laser field. The atom moves with velocity v along the probe laser field, and due to the Doppler broadening the precision of the spatial information deteriorates significantly. It is found that via a microwave field, precision in the position measurement of a single hot rubidium atom can be attained, overcoming the limitation posed by the Doppler shift.

  8. Transversal Doppler-Fizeau effect

    International Nuclear Information System (INIS)

    Subacius, E.

    1981-01-01

    The relativistic calculation of the Doppler-Fizeau effect foresees a second grade redshift due to the proper time dilation of a moving object. The relevance of this relativistic effect on astrophysical observation is discussed, herein. (Auhor) [pt

  9. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  10. Doppler-broadening of positron annihilation in a biological environment

    International Nuclear Information System (INIS)

    Torrisi, L.; La Mela, C.; Catania, Univ.

    1997-01-01

    The aim of this study was to investigate the Doppler effect of the 511 keV γ peak from positron annihilation in biological matter: The broadening of the annihilation peak is due to positron annihilation with electrons that have high momentum. In aqueous solutions annihilation depends on the temperature and it is linked positronium formation. Measurements in vivo, on human brain, were taken during the diagnosis of positron emission tomography (PET) on healthy patients by injecting them with the beta emitter of short lifetime 18F . The Doppler-broadening in biological tissues rich in water content decreased significantly compared to biological solutions and water

  11. Glare Spot Phase Doppler Anemometry

    OpenAIRE

    Hespel, Camille; Ren, Kuan Fang; Gréhan, Gérard; Onofri, Fabrice

    2006-01-01

    International audience; The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index is also necessary since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemo...

  12. Modeling and processing of laser Doppler reactive hyperaemia signals

    Science.gov (United States)

    Humeau, Anne; Saumet, Jean-Louis; L'Huiller, Jean-Pierre

    2003-07-01

    Laser Doppler flowmetry is a non-invasive method used in the medical domain to monitor the microvascular blood cell perfusion through tissue. Most commercial laser Doppler flowmeters use an algorithm calculating the first moment of the power spectral density to give the perfusion value. Many clinical applications measure the perfusion after a vascular provocation such as a vascular occlusion. The response obtained is then called reactive hyperaemia. Target pathologies include diabetes, hypertension and peripheral arterial occlusive diseases. In order to have a deeper knowledge on reactive hyperaemia acquired by the laser Doppler technique, the present work first proposes two models (one analytical and one numerical) of the observed phenomenon. Then, a study on the multiple scattering between photons and red blood cells occurring during reactive hyperaemia is carried out. Finally, a signal processing that improves the diagnosis of peripheral arterial occlusive diseases is presented.

  13. Parametric Investigation of Laser Doppler Microphones

    Science.gov (United States)

    Daoud, M.; Naguib, A.

    2002-11-01

    The concept of a Laser Doppler Microphone (LDM) is based on utilizing the Doppler frequency shift of a focused laser beam to measure the unsteady velocity of the center point of a flexible polymer diaphragm that is mounted on top of a hole and subjected to the unsteady pressure. Time integration of the velocity signal yields a time series of the diaphragm displacement, which can be converted to pressure from knowledge of the sensor's deflection sensitivity. In our APS/DFD presentation last year, the stringent frequency resolution requirement of these new sensors and methods to meet this requirement were discussed. Here, the dependence of the sensor characteristics (sensitivity, bandwidth, and noise floor) on various significant parameters is investigated in detail by calibrating the sensor in a plane wave tube in the frequency range of 50 - 5000 Hz. Parameters investigated include sensor diaphragm material and thickness, sensor size, damping of the diaphragm motion and laser beam spot size. The results shed light on the operating limits of the new sensor and demonstrate its ability to conduct high-spatial-resolution measurements in typical high-Reynolds-number test facilities. Moreover, calibrated LDM sensors were used to conduct measurements in a separating/reattaching flow and the results are compared to classical electret-type microphones with a similar sensing diameter.

  14. Doppler reflectometry for the investigation of poloidally propagating density perturbations

    International Nuclear Information System (INIS)

    Hirsch, M.; Baldzuhn, J.; Kurzan, B.; Holzhauer, E.

    1999-01-01

    A modification of microwave reflectometry is discussed where the direction of observation is tilted with respect to the normal onto the reflecting surface. The experiment is similar to scattering where a finite resolution in k-space exists but keeps the radial localization of reflectometry. The observed poloidal wavenumber is chosen by Bragg's condition via the tilt angle and the resolution in k-space is determined by the antenna pattern. From the Doppler shift of the reflected wave the poloidal propagation velocity of density perturbations is obtained. The diagnostic capabilities of Doppler reflectometry are investigated using full wave code calculations. The method offers the possibility to observe changes in the poloidal propagation velocity of density perturbations and their radial shear with a temporal resolution of about 10μs. (authors)

  15. New clutter-rejection algorithm for Doppler ultrasound

    Science.gov (United States)

    Cloutier, Guy; Chen, Danmin; Durand, Louis-Gilles

    2002-04-01

    Several strategies, known as clutter or wall Doppler filtering, were proposed to remove the strong echoes produced by stationary or slow moving tissue structures from the Doppler blood flow signal. In this study, the matching pursuit (MP) method is proposed to remove clutter components. The MP method decomposes the Doppler signal into wavelet atoms that are selected in a decreasing energy order. Thus, the high-energy clutter components are extracted first. In the present study, the pulsatile Doppler signal s(n) was simulated by a sum of random-phase sinusoids. Two types of high-amplitude clutter signals were then superimposed on s(n): a time-varying low frequency component (type 1), covering systole and early diastole, and short transient clutter signals (type 2), distributed within the whole cardiac cycle. The Doppler signals were modeled with the MP method and the most dominant atoms were subtracted until the signal-to-clutter (S/C) ratio reached a maximum. For the type 1 clutter signal, the improvement in the S/C ratio was 19.0 +/- 0.6 dB, and 72.0 +/- 4.5 atoms were required to reach this performance. For the transient type 2 clutter signal, exactly 10 atoms were required and the maximum improvement in S/C ratio was 5.5 +/- 0.5 dB. These results suggest the possibility of using this signal processing approach to implement clutter rejection filters on ultrasound commercial instruments.

  16. Phase Doppler anemometry as an ejecta diagnostic

    Science.gov (United States)

    Bell, D. J.; Chapman, D. J.

    2017-01-01

    When a shock wave is incident on a free surface, micron sized pieces of the material can be ejected from that surface. Phase Doppler Anemometry (PDA) is being developed to simultaneously measure the sizes and velocities of the individual shock induced ejecta particles; providing an important insight into ejecta phenomena. The results from experiments performed on the 13 mm bore light gas gun at the Institute of Shock Physics, Imperial College London are presented. Specially grooved tin targets were shocked at pressures of up to 14 GPa, below the melt on release pressure, to generate ejecta particles. These experiments are the first time that PDA has been successfully fielded on dynamic ejecta experiments. The results and current state of the art of the technique are discussed along with the future improvements required to optimise performance and increase usability.

  17. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  18. Doppler Broadening Calculations of Compton Scattering for Molecules, Plastics, Tissues, and Few Biological Materials in the X-Ray Region: An Analysis in Terms of Compton Broadening and Geometrical Energy Broadening

    Science.gov (United States)

    Rao, D. V.; Cesareo, R.; Brunetti, A.; Gigante, G. E.; Akatsuka, T.; Takeda, T.; Itai, Y.

    2004-09-01

    Relativistic and nonrelativistic Compton profile cross sections for H, C, N, O, P, and Ca and for a few important biological materials such as water, polyethylene, lucite, polystyrene, nylon, polycarbonate, bakelite, fat, bone and calcium hydroxyapatite are estimated for a number of Kα x-ray energies and for 59.54 keV (Am-241) γ photons. Energy broadening and geometrical broadening (ΔG) is estimated by assuming θmin and θmax are symmetrically situated around θ=90°. FWHM of J(PZ) and FWHM of Compton energy broadening are evaluated at various incident photon energies. These values are estimated around the centroid of the Compton profile with an energy interval of 0.1 and 1.0 keV for 59.54 keV photons. Total Compton, individual shell, and Compton energy-absorption scattering cross sections are evaluated in the energy region from 0.005 to 0.5 MeV. It is an attempt to know the effect of Doppler broadening for single atoms, many of which constitute the biological materials.

  19. Proteome Analysis of Human Arterial Tissue Discloses Associations Between the Vascular Content of Small Leucine-Rich Repeat Proteoglycans and Pulse Wave Velocity

    DEFF Research Database (Denmark)

    Lyck Hansen, Maria; Beck, Hans Christian; Irmukhamedov, Akhmadjon

    2015-01-01

    OBJECTIVES: We hypothesized that arterial stiffness is associated with changes in the arterial protein profile, particularly of extracellular matrix components. We aimed at determining differentially expressed proteins by quantitative proteome analysis in arterial tissue from patients with differ......OBJECTIVES: We hypothesized that arterial stiffness is associated with changes in the arterial protein profile, particularly of extracellular matrix components. We aimed at determining differentially expressed proteins by quantitative proteome analysis in arterial tissue from patients...... with different degrees of arterial stiffness. APPROACH AND RESULTS: Arterial stiffness, assessed by carotid-femoral pulse wave velocity (PWV), central blood pressure and augmentation index by pulse wave analysis were measured the day before surgery in a group of patients undergoing coronary artery bypass...... grafting. Protein extracts of well-defined, homogenous, nonatherosclerotic individual samples of the left mammary artery from 10 of these patients with high PWV and 9 with low PWV were compared by quantitative proteome analysis, using tandem mass tag labeling and nano-liquid chromatography mass...

  20. Christian Andreas Doppler--the man and his legacy.

    Science.gov (United States)

    Coman, I M

    2005-01-01

    Reminding the life and legacy of the Austrian Scientist who discovered the famous 'Doppler Effect'. C.A. Doppler was born the 29th of November 1803 in Salzburg. After studies in Linz and Vienna, he graduated in mathematics, became assistant at the University and later worked as a professor in Prague. Back to Vienna, he was appointed as professor at the Polytechnic School and --in 1850--as first director of the new Institute of Physics. C.A. Doppler did publish on magnetism, electricity, optics, and astronomy. He remains in the history of science due to the discovery presented (May 25, 1842) at the Royal Bohemian Society of Science entitled "On the colored light of the double stars and certain other stars of the heavens"; the paper described (applied to light) the shift of frequency which bears nowadays his name. The theory was later experimentally proven and--extended for any electromagnetic and acoustic waves--got myriads if applications in astronomy, physics, aviation, meteorology, and health science. Satomura in Japan (1955) published it's first ultrasound vascular application--with successive achievements in the next decades. Doppler ultrasonagraphy became the main noninvasive instrument for functional assesment of heart and vessels.

  1. Value of tissue Doppler-derived Tei index and two-dimensional speckle tracking imaging derived longitudinal strain on predicting outcome of patients with light-chain cardiac amyloidosis.

    Science.gov (United States)

    Liu, Dan; Hu, Kai; Herrmann, Sebastian; Cikes, Maja; Ertl, Georg; Weidemann, Frank; Störk, Stefan; Nordbeck, Peter

    2017-06-01

    Prognosis of patients with light-chain cardiac amyloidosis (AL-CA) is poor. Speckle tracking imaging (STI) derived longitudinal deformation parameters and Doppler-derived left ventricular (LV) Tei index are valuable predictors of outcome in patients with AL-CA. We estimated the prognostic utility of Tei index and deformation parameters in 58 comprehensively phenotyped patients with AL-CA after a median follow-up of 365 days (quartiles 121, 365 days). The primary end point was all-cause mortality. 19 (33%) patients died during follow-up. Tei index (0.89 ± 0.29 vs. 0.61 ± 0.16, p < 0.001) and E to global early diastolic strain rate ratio (E/GLSR dias ) were higher while global longitudinal systolic strain (GLS sys ) was lower in non-survivors than in survivors (all p < 0.05). Tei index, NYHA functional class, GLS sys and E/GLSR dias were independent predictors of all-cause mortality risk, and Tei index ≥0.9 (HR 7.01, 95% CI 2.43-20.21, p < 0.001) was the best predictor of poor outcome. Combining Tei index and GLS sys yielded the best results on predicting death within 1 year (100% with Tei index ≥0.9 and GLS sys ≤13%) or survival (95% with Tei index ≤0.9 and GLS sys ≥13%). We conclude that 1-year mortality risk in AL-CA patients can be reliably predicted using Tei index or deformation parameters, with combined analysis offering best performance.

  2. Doppler broadening of cross sections

    International Nuclear Information System (INIS)

    Buckler, P.A.C.; Pull, I.C.

    1962-12-01

    Expressions for temperature dependent cross-sections in terms of resonance parameters are obtained, involving generalisations of the conventional Doppler functions, ψ and φ. Descriptions of Fortran sub-routines, which calculate broadened cross-sections in accordance with the derived formulae, are included. (author)

  3. The Doppler paradox.

    Science.gov (United States)

    Ntalas, Ioannis; Karády, Júlia; Kapetanakis, Stam; Rajani, Ronak

    2017-12-01

    Obstructive prosthetic valve thrombosis (PVT) is a rare but severe complication that usually occurs in the presence of suboptimal anticoagulation. Although fluoroscopy is commonly used to detect abnormal leaflet motion as a surrogate marker for PVT, its inability to directly visualize adjacent tissue and valve physiology leaves it susceptible to miss clinically important PVT. In this manuscript, we report the case of a 54-year-old woman with a mechanical mitral valve who was admitted to our institute with exertional dyspnea. Although valve fluoroscopy was normal, subsequent 3D echocardiography and ECG-gated multiphase computed tomography confirmed the presence of PVT that was subsequently treated successfully with surgical replacement. Our case demonstrates the utility of multimodality imaging in establishing PVT in patients with abnormal prosthetic valve physiology and progressive symptoms. © 2017, Wiley Periodicals, Inc.

  4. Anomalous Doppler effects in bulk phononic crystal

    International Nuclear Information System (INIS)

    Cai Feiyan; He Zhaojian; Zhang Anqi; Ding Yiqun; Liu Zhengyou

    2010-01-01

    Doppler effects in simple cubic phononic crystal are studied theoretically and numerically. In addition to observing Doppler shifts from a moving source's frequencies inside the gap, we find that Doppler shifts can be multi-order, anisotropic, and the dominant order of shift depends on the band index that the source's frequency is in.

  5. Efficacy and safety of extracorporeal shock wave therapy for acute and chronic soft tissue wounds: A systematic review and meta-analysis.

    Science.gov (United States)

    Zhang, Li; Fu, Xiao-Bing; Chen, Shuo; Zhao, Zhan-Bo; Schmitz, Christoph; Weng, Chang-Shui

    2018-04-19

    This study aimed to evaluate and compare the effects of extracorporeal shock wave therapy (ESWT) and conventional wound therapy (CWT) for acute and chronic soft tissue wounds. All English-language articles on ESWT for acute and chronic soft tissue wounds indexed in PubMed, Medline, Embase, Cochrane Central Register of Controlled Trials, Cochrane Library, Physiotherapy Evidence Database, and HealthSTAR published prior to June 2017 were included, as well as corresponding articles cited in reference lists of related review articles. The methodological quality of the selected studies was assessed with the Cochrane Collaboration's "risk of bias" tool. Study design, subject demographics, wound aetiology, treatment protocols, assessment indexes, and follow-up duration were extracted. The fixed or random-effects model was used to calculate the pooled effect sizes according to studies' heterogeneity. Ten randomised controlled trials (RCTs) involving 473 patients were included in this systematic review and meta-analysis. The meta-analysis showed that ESWT statistically significantly increased the healing rate of acute and chronic soft tissue wounds 2.73-fold (odds ratio, OR = 3.73, 95% confidence interval, CI: 2.30-6.04, P SMD) = 30.45; 95% CI: 23.79-37.12; P SMD = -2.86, 95% CI:-3.78 to -1.95, P SMD = -19.11, 95% CI: -23.74 to -14.47, P infection by 53% (OR = 0.47, 95% CI: 0.24-0.92, P = .03) when compared with CWT alone. Serious adverse effects were not reported. ESWT showed better therapeutic effects on acute and chronic soft tissue wounds compared with CWT alone. However, higher-quality and well-controlled RCTs are needed to further assess the role of ESWT for acute and chronic soft tissue wounds. © 2018 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  6. In-vivo quantitative measurement of tissue oxygen saturation of human webbing using a transmission type continuous-wave near-infrared spectroscopy

    Science.gov (United States)

    Aizimu, Tuerxun; Adachi, Makoto; Nakano, Kazuya; Ohnishi, Takashi; Nakaguchi, Toshiya; Takahashi, Nozomi; Nakada, Taka-aki; Oda, Shigeto; Haneishi, Hideaki

    2018-02-01

    Near-infrared spectroscopy (NIRS) is a noninvasive method for monitoring tissue oxygen saturation (StO2). Many commercial NIRS devices are presently available. However, the precision of those devices is relatively poor because they are using the reflectance-model with which it is difficult to obtain the blood volume and other unchanged components of the tissue. Human webbing is a thin part of the hand and suitable to measure spectral transmittance. In this paper, we present a method for measuring StO2 of human webbing from a transmissive continuous-wave nearinfrared spectroscopy (CW-NIRS) data. The method is based on the modified Beer-Lambert law (MBL) and it consists of two steps. In the first step, we give a pressure to the upstream region of the measurement point to perturb the concentration of deoxy- and oxy-hemoglobin as remaining the other components and measure the spectral signals. From the measured data, spectral absorbance due to the components other than hemoglobin is calculated. In the second step, spectral measurement is performed at arbitrary time instance and the spectral absorbance obtained in the step 1 is subtracted from the measured absorbance. The tissue oxygen saturation (StO2) is estimated from the remained data. The method was evaluated on an arterial occlusion test (AOT) and a venous occlusion test (VOT). In the evaluation experiment, we confirmed that reasonable values of StO2 were obtained by the proposed method.

  7. Color Doppler flow mapping of stenotic and regurgitant natural heart valves

    International Nuclear Information System (INIS)

    Nanda, N.C.

    1986-01-01

    Color Doppler echocardiography has found widest application in reliable detection and assessment of severity of both atrio-ventricular and semi-lunar valve incompetence. The authors believe both the sensitivity and specificity of color Doppler for the detection of mitral and aortic regurgitation is very high in patients with adequate acoustic windows. In 82 patients with proven mitral regurgitation studied, the best correlations with angiography were noted when the maximum or average regurgitant jet are obtained by color Doppler from three standard 2-D echo planes (parasternal long and short axis and apical four chamber view) and expressed as a percentage of the left atrial area were considered. The criteria the authors used for assessment of tricuspid and pulmonary valve incompetence are similar to those used for mitral and aortic valve incompetence, but the lack of a good ''gold'' standard has hampered validation. The color Doppler technique also supplements conventional Doppler in the assessment of severity of stenotic lesions by facilitating parallel alignment of the continuous wave Doppler cursor line with the stenotic jet for accurate recording of maximal velocities and pressure gradients. The authors have found this method especially useful in the assessment of aortic stenosis. In conclusion, color Doppler flow mapping combined with conventional echocardiography provides, for the first time, a comprehensive noninvasive assessement of the severity of regurgitant and stenotic lesions

  8. Heavy metal distribution in organic and siliceous marine sponge tissues measured by square wave anodic stripping voltammetry.

    Science.gov (United States)

    Illuminati, S; Annibaldi, A; Truzzi, C; Scarponi, G

    2016-10-15

    May sponge spicules represent a "tank" to accumulate heavy metals? In this study we test this hypothesis determining the distribution of Cd, Pb and Cu concentrations between organic and siliceous tissues in Antarctic Demospongia (Sphaerotylus antarcticus, Kirkpatrikia coulmani and Haliclona sp.) and in the Mediterranean species Petrosia ficiformis. Results show that although, in these sponges, spicules represent about 80% of the mass content, the accumulation of pollutant is lower in the spicules than in the corresponding organic fraction. The contribution of tissues to the total sponge content of Cd, Pb and Cu is respectively 99%, 82% and 97% for Antarctic sponges and 96%, 95% and 96% for P. ficiformis, similar in polar and temperate organisms. These results pave the way to a better understanding of the role of marine sponges in uptaking heavy metals and to their possible use as monitor of marine ecosystems, recommend by the Water Framework Directive. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  10. Design of an integrated photo detector circuit for laser doppler blood flow monitoring

    NARCIS (Netherlands)

    Nieland, J.; Nieland, J.; van Kranenburg, H.; Wallinga, Hans; Serov, Alexander; Steenbergen, Wiendelt; de Mul, F.F.M.

    1999-01-01

    A method to measure the blood perfusion of tissue is to apply photons to tissue and measure the frequency shift of the Doppler shifted photons.. To avoid the use of fibers, a chip was designed which contains photodetectors and electronic circuitry to amplify the signal. This IC serves as an

  11. Spatial weighting of Doppler reactivity feedback

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Todosow, M.

    1977-12-01

    The spatial weighting of the local Doppler feedback implicit in the determination of the core Doppler feedback reactivity has been investigated. Using a detailed planar PDQ7-II PWR model with local fuel-temperature feedback, the core Doppler spatial weight factor, S, has been determined for various control patterns and power levels. Assuming power-squared weighting of the local Doppler feedback, a simple analytic expression for S has been derived and, based on comparison with the PDQ7-II results, provides a convenient and accurate representation of the Doppler spatial weight factor. The sensitivity of these results to variations in the fuel rod heat transfer coefficients, fuel loading and the magnitude of the Doppler coefficient has also been evaluated. The dependence of the local Doppler coefficient on moderator temperature, boron concentration and control rod density has been determined and found to be weak. Selected comparisons with vendor analyses have been made and indicate general agreement

  12. Fractionated Repetitive Extracorporeal Shock Wave Therapy: A New Standard in Shock Wave Therapy?

    Directory of Open Access Journals (Sweden)

    Tobias Kisch

    2015-01-01

    Full Text Available Background. ESWT has proven clinical benefit in dermatology and plastic surgery. It promotes wound healing and improves tissue regeneration, connective tissue disorders, and inflammatory skin diseases. However, a single treatment session or long intervals between sessions may reduce the therapeutic effect. The present study investigated the effects of fractionated repetitive treatment in skin microcirculation. Methods. 32 rats were randomly assigned to two groups and received either fractionated repetitive high-energy ESWT every ten minutes or placebo shock wave treatment, applied to the dorsal lower leg. Microcirculatory effects were continuously assessed by combined laser Doppler imaging and photospectrometry. Results. In experimental group, cutaneous tissue oxygen saturation was increased 1 minute after the first application and until the end of the measuring period at 80 minutes after the second treatment (P<0.05. The third ESWT application boosted the effect to its highest extent. Cutaneous capillary blood flow showed a significant increase after the second application which was sustained for 20 minutes after the third application (P<0.05. Placebo group showed no statistically significant differences. Conclusions. Fractionated repetitive extracorporeal shock wave therapy (frESWT boosts and prolongs the effects on cutaneous hemodynamics. The results indicate that frESWT may provide greater benefits in the treatment of distinct soft tissue disorders compared with single-session ESWT.

  13. A Doppler Radar System for Sensing Physiological Parameters in Walking and Standing Positions

    Directory of Open Access Journals (Sweden)

    Malikeh Pour Ebrahim

    2017-03-01

    Full Text Available Doppler radar can be implemented for sensing physiological parameters wirelessly at a distance. Detecting respiration rate, an important human body parameter, is essential in a range of applications like emergency and military healthcare environments, and Doppler radar records actual chest motion. One challenge in using Doppler radar is being able to monitor several patients simultaneously and in different situations like standing, walking, or lying. This paper presents a complete transmitter-receiver Doppler radar system, which uses a 4 GHz continuous wave radar signal transmission and receiving system, to extract base-band data from a phase-shifted signal. This work reports experimental evaluations of the system for one and two subjects in various standing and walking positions. It provides a detailed signal analysis of various breathing rates of these two subjects simultaneously. These results will be useful in future medical monitoring applications.

  14. Shear wave elastography using ultrasound: effects of anisotropy and stretch stress on a tissue phantom and reactive lymph nodes in the neck

    Directory of Open Access Journals (Sweden)

    Ha Young Lee

    2017-01-01

    Full Text Available Purpose The purpose of this study was to evaluate how the anisotropy and the static stretch stress of the cervical musculature influence the measured shear modulus in a tissue-mimicking phantom and in cervical lymph nodes in vivo by using shear wave elastography (SWE. Methods SWE was performed on a phantom using a pig muscle and on the middle jugular cervical lymph nodes in six volunteers. Tissue elasticity was quantified using the shear modulus and a supersonic shear wave imaging technique. For the phantom study, first, the optimal depth for measurement was determined, and then, SWE was performed in parallel and perpendicular to the muscle fiber orientation with and without strain stress. For the in vivo study, SWE was performed on the cervical lymph nodes in parallel and perpendicular to the sternocleidomastoid muscle fiber direction with and without neck stretching. The mean values of the shear modulus (meanSM were then analyzed. Results In the phantom study, the measured depth significantly influenced the meanSM with a sharp decrease at the depth of 1.5 cm (P<0.001. Strain stress increased the meanSM, irrespective of the muscle fiber orientation (P<0.001. In the in vivo study, the meanSM values obtained in parallel to the muscle fiber orientation were greater than those obtained perpendicular to the fiber orientation, irrespective of the stretch stress (P<0.001. However, meanSM was affected significantly by the stretch stress parallel to the muscle fiber orientation (P<0.001. Conclusion The anisotropic nature of the cervical musculature and the applied stretch stress explain the variability of the SWE measurements and should be identified before applying SWE for the interpretation of the measured shear modulus values.

  15. Laser Doppler flowmetry in endodontics: a review.

    Science.gov (United States)

    Jafarzadeh, H

    2009-06-01

    Vascular supply is the most accurate marker of pulp vitality. Tests for assessing vascular supply that rely on the passage of light through a tooth have been considered as possible methods for detecting pulp vitality. Laser Doppler flowmetry (LDF), which is a noninvasive, objective, painless, semi-quantitative method, has been shown to be reliable for measuring pulpal blood flow. The relevant literature on LDF in the context of endodontics up to March 2008 was reviewed using PubMed and MEDLINE database searches. This search identified papers published between June 1983 and March 2008. Laser light is transmitted to the pulp by means of a fibre optic probe. Scattered light from moving red blood cells will be frequency-shifted whilst that from the static tissue remains unshifted. The reflected light, composed of Doppler-shifted and unshifted light, is returned by afferent fibres and a signal is produced. This technique has been successfully employed for estimating pulpal vitality in adults and children, differential diagnosis of apical radiolucencies (on the basis of pulp vitality), examining the reactions to pharmacological agents or electrical and thermal stimulation, and monitoring of pulpal responses to orthodontic procedures and traumatic injuries. Assessments may be highly susceptible to environmental and technique-related factors. Nonpulpal signals, principally from periodontal blood flow, may contaminate the signal. Because this test produces no noxious stimuli, apprehensive or distressed patients accept it more readily than current methods of pulp vitality assessment. A review of the literature and a discussion of the application of this system in endodontics are presented.

  16. Thermal wave propagation in blood perfused tissues under hyperthermia treatment for unique oscillatory heat flux at skin surface and appropriate initial condition

    Science.gov (United States)

    Dutta, Jaideep; Kundu, Balaram

    2018-05-01

    This paper aims to develop an analytical study of heat propagation in biological tissues for constant and variable heat flux at the skin surface correlated with Hyperthermia treatment. In the present research work we have attempted to impose two unique kind of oscillating boundary condition relevant to practical aspect of the biomedical engineering while the initial condition is constructed as spatially dependent according to a real life situation. We have implemented Laplace's Transform method (LTM) and Green Function (GFs) method to solve single phase lag (SPL) thermal wave model of bioheat equation (TWMBHE). This research work strongly focuses upon the non-invasive therapy by employing oscillating heat flux. The heat flux at the skin surface is considered as constant, sinusoidal, and cosine forms. A comparative study of the impact of different kinds of heat flux on the temperature field in living tissue explored that sinusoidal heat flux will be more effective if the time of therapeutic heating is high. Cosine heating is also applicable in Hyperthermia treatment due to its precision in thermal waveform. The result also emphasizes that accurate observation must be required for the selection of phase angle and frequency of oscillating heat flux. By possible comparison with the published experimental research work and published mathematical study we have experienced a difference in temperature distribution as 5.33% and 4.73%, respectively. A parametric analysis has been devoted to suggest an appropriate procedure of the selection of important design variables in viewpoint of an effective heating in hyperthermia treatment.

  17. Impact of Fibrotic Tissue on Shear Wave Velocity in Thyroid: An Ex Vivo Study with Fresh Thyroid Specimens

    Directory of Open Access Journals (Sweden)

    Takahiro Fukuhara

    2015-01-01

    Full Text Available We sought to elucidate the correlation between shear wave velocity (SWV and fibrosis in thyroid by precisely assessing pathological structures inside 5 × 5 mm2 regions of interest (ROIs of resected specimens, under conditions that excluded physical artifacts. The materials were unselected thyroid and lymph node specimens resected during thyroid surgery. Immediately after surgery, fresh unfixed thyroid and metastatic lymph node specimens were suspended in gel phantoms, and SWV was measured. Upon pathological examination of each specimen, the extent of fibrosis was graded as none, moderate, or severe. A total of 109 specimens were evaluated: 15 normal thyroid, 16 autoimmune thyroiditis, 40 malignant nodules, 19 benign thyroid nodules, and 19 metastatic lymph nodes. When all specimens were classified according to the degree of fibrosis determined by pathological imaging, the mean SWV was 1.49±0.39 m/s for no fibrosis, 2.13±0.66 m/s for moderate fibrosis, and 2.68±0.82 m/s for severe fibrosis. The SWVs of samples with moderate and severe fibrosis were significantly higher than those of samples without fibrosis. The results of this study demonstrate that fibrosis plays an important role in determining stiffness, as measured by SWV in thyroid.

  18. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  19. Understanding the Doppler Effect by Analysing Spectrograms of the Sound of a Passing Vehicle

    Science.gov (United States)

    Lubyako, Dmitry; Martinez-Piedra, Gordon; Ushenin, Arthur; Ushenin, Arthur; Denvir, Patrick; Dunlop, John; Hall, Alex; Le Roux, Gus; van Someren, Laurence; Weinberger, Harvey

    2017-01-01

    The purpose of this paper is to demonstrate how the Doppler effect can be analysed to deduce information about a moving source of sound waves. Specifically, we find the speed of a car and the distance of its closest approach to an observer using sound recordings from smartphones. A key focus of this paper is how this can be achieved in a…

  20. Quantum Interference between Autonomous Single-Photon Sources from Doppler-Broadened Atomic Ensemble

    OpenAIRE

    Jeong, Teak; Lee, Yoon-Seok; Park, Jiho; Kim, Heonoh; Moon, Han Seb

    2017-01-01

    To realize a quantum network based on quantum entanglement swapping, bright and completely autonomous sources are essentially required. Here, we experimentally demonstrate Hong-Ou-Mandel (HOM) quantum interference between two independent bright photon pairs generated via the spontaneous four-wave mixing in Doppler-broadened ladder-type 87Rb atoms. Bright autonomous heralded single photons are operated in a continuous-wave (CW) mode with no synchronization or supplemental filters. The four-fol...

  1. Transition from Spirals to Defect-Mediated Turbulence Driven by a Doppler Instability

    International Nuclear Information System (INIS)

    Ouyang, Qi; Swinney, Harry L.; Li, Ge

    2000-01-01

    A transition from rotating chemical spirals to turbulence is observed in experiments on the Belousov-Zhabotinsky reaction. The transition occurs when the waves near the spiral tip spontaneously break, generating defects. Measurements reveal that this defect-mediated turbulence is caused by the Doppler effect on the traveling waves. The observations are in good accord with numerical simulations and theory. (c) 2000 The American Physical Society

  2. Measurement of ventricular function using Doppler ultrasound

    International Nuclear Information System (INIS)

    Teague, S.M.

    1986-01-01

    Doppler has wide application in the evaluation of valvular heart disease. The need to know ventricular function is a much more common reason for an echocardiographic evaluation. Interestingly, Doppler examinations can assess ventricular function from many perspectives. Description of ventricular function entails measurement of the timing, rate and volume of ventricular filling and ejection. Doppler ultrasound examination reveals all of these aspects of ventricular function noninvasively, simply, and without great expense or radiation exposure, as described in this chapter

  3. Hydronephrosis and pregnancy: study with Doppler echography

    International Nuclear Information System (INIS)

    Ripolles Gonzalez, T.R.; Ambit Capdevilla, S.; Sanguesa Nebot, C.; Lazaro, S. de; Garcia Vila, J.H.; Belloch Ugarte, V.

    1993-01-01

    An 18-month study was performed to establish the normal intrarenal resistance index during pregnancy, in order to determine whether it differed significantly depending on the week of gestation or the degree of hydronephrosis. For this purpose , the flow velocity waves obtained in right kidney were analyzed in a group of 112 patients on the basis of 209 explorations. The kidneys were classified as grade 0,I,II, or III according to the degree of hydronephrosis. Doppler signal sampling was carried out at the level of the corticomedullary junction. From the results of the study it can be deduced that the index of intrarenal resistance during pregnancy is similar to that of the general population, that there are no significant differences among the groups with different degree of hydronephrosis and that the index does not vary according to the different weeks of gestation. These findings suggest that, during pregnancy, a pathological resistance index in a kidney should not be attributed to the physiological changes associated with normal gestation. (Author) 21 refs

  4. Direct Doppler auscultation of the carotid arteries

    International Nuclear Information System (INIS)

    Nix, L.

    1984-01-01

    The results of the carotid Doppler examinations and contrast arteriograms are presented. The overall sensitivity of the carotid Doppler examinations in detecting severe stenosis or occlusion of the carotid artery was 92%. The Doppler studies correctly differentiated these two conditions in 84% of the diseased vessels. In carotid arteries with stenosis greater than or equal to 50%, the sensitivity of the Doppler examinations was 90%, and these studies suggested stenosis in all but two of the 36 abnormal examinations. In two patent carotids with greater than 90% stenosis, a signal could not be elicited, presumably because of the low blood flow through the severely stenotic segment

  5. Three-dimensional power Doppler sonography in screening for carotid artery disease.

    Science.gov (United States)

    Keberle, M; Jenett, M; Beissert, M; Jahns, R; Haerten, R; Hahn, D

    2000-01-01

    Color Doppler sonography has gained considerable recognition as a noninvasive method to detect carotid artery disease and to assess the degree of carotid artery stenosis. However, results are highly operator-dependent and cannot be presented as survey images. The purpose of this study was to evaluate real-time 3-dimensional (3D) power Doppler sonography as a method for screening for atherosclerosis in the carotid arteries. We prospectively screened 75 patients for carotid artery disease using both conventional color Doppler sonography and 3D power Doppler sonography, and the results from the 2 modalities were compared. A total of 150 common carotid arteries, 150 internal carotid arteries, and 150 external carotid arteries were examined utilizing a 7.5-MHz linear-array transducer combined with tissue harmonic imaging. Color Doppler sonography detected 297 normal or atherosclerotic arteries without stenosis, 57 arteries with mild (1-49%) stenosis, 41 with moderate (50-69%) stenosis, 32 with severe (70-99%) stenosis, and 9 with occlusions. The degree of stenosis determined by color Doppler sonography correlated with that determined by 3D power Doppler sonography (r = 0.982-0.998). Moreover, there was a good correlation between the measurements for both the length of the lesion and its distance from the bulb as determined by the 3D volume surveys and by color Doppler sonography (r = 0.986). The interobserver variability rate was 3.7% +/- 0.5%. Generally, the acquisition and reconstruction of the 3D data took less than 5 minutes. 3D power Doppler sonography is easy to perform and is an accurate method in screening for atherosclerotic lesions of the carotid arteries. Moreover, it provides excellent 3D volume surveys that may be helpful in the planning of surgical treatment. Copyright 2000 John Wiley & Sons, Inc.

  6. Mucosal blood flow measurements using laser Doppler perfusion monitoring

    Institute of Scientific and Technical Information of China (English)

    Dag Arne Lihaug Hoff; Hans Gregersen; Jan Gunnar Hatlebakk

    2009-01-01

    Perfusion of individual tissues is a basic physiological process that is necessary to sustain oxygenation and nutrition at a cellular level. Ischemia, or the insufficiency of perfusion, is a common mechanism for tissue death or degeneration, and at a lower threshold, a mechanism for the generation of sensory signalling including pain. It is of considerable interest to study perfusion of peripheral abdominal tissues in a variety of circumstances. Microvascular disease of the abdominal organs has been implicated in the pathogenesis of a variety of disorders, including peptic ulcer disease, inflammatory bowel disease and chest pain. The basic principle of laser Doppler perfusion monitoring (LDPM) is to analyze changes in the spectrum of light reflected from tissues as a response to a beam of monochromatic laser light emitted. It reflects the total local microcirculatory blood perfusion, including perfusion in capillaries, arterioles, venules and shunts. During the last 20-25 years, numerous studies have been performed in different parts of the gastrointestinal (GI) tract using LDPM. In recent years we have developed a multi-modal catheter device which includes a laser Doppler probe, with the intent primarily to investigate patients suffering from functional chest pain of presumed oesophageal origin. Preliminary studies show the feasibility of incorporating LDPM into such catheters for performing physiological studies in the GI tract. LDPM has emerged as a research and clinical tool in preference to other methods; but, it is important to be aware of its limitations and account for them when reporting results.

  7. Doppler sonographic evaluation of ophthalmic arterial flow pattern in hypertensive patients

    International Nuclear Information System (INIS)

    Ryu, Dae Sik; Kim, Young Goo

    1994-01-01

    To compare the Doppler velocity waveform pattern of ophthalmic artery of hypertensive patients with that of normotensive subjects. Doppler velocity waveform was obtained from ophthalmic artery in 45 hypertensive patients and 60 normotensive subjects. Both hypertensives and normotensive subjects were classified according to age into those younger than and those older than 45 years. Doppler indices(pulsatility index(PI), resistance index(RI), the first systolic peak/the second systolic peak(S1/S2), the first systolic peak/diastolic peak(S1/D)) measured in hypertensive patients were compared with normotensive subjects. Among the various doppler indices, only S1/S2 showed significant difference(P < 0.05) between the hypertensive patients and normotensive subjects younger than 45 years. Doppler velocity waveform of hypertensive patients older than 45 years showed no significant difference from that of normotensive subjects with corresponding age. Doppler velocity waveform of ophthalmic artery in hypertensive patients younger than 45 years shows pattern with S2 higher than that of normotensive subjects. High S2 component(reflective-wave) may represent increased vascular impedance due to vasococonstriction of retinal arterioles in hypertensive patients

  8. A discrete electromechanical model for human cardiac tissue: effects of stretch-activated currents and stretch conditions on restitution properties and spiral wave dynamics.

    Science.gov (United States)

    Weise, Louis D; Panfilov, Alexander V

    2013-01-01

    We introduce an electromechanical model for human cardiac tissue which couples a biophysical model of cardiac excitation (Tusscher, Noble, Noble, Panfilov, 2006) and tension development (adjusted Niederer, Hunter, Smith, 2006 model) with a discrete elastic mass-lattice model. The equations for the excitation processes are solved with a finite difference approach, and the equations of the mass-lattice model are solved using Verlet integration. This allows the coupled problem to be solved with high numerical resolution. Passive mechanical properties of the mass-lattice model are described by a generalized Hooke's law for finite deformations (Seth material). Active mechanical contraction is initiated by changes of the intracellular calcium concentration, which is a variable of the electrical model. Mechanical deformation feeds back on the electrophysiology via stretch-activated ion channels whose conductivity is controlled by the local stretch of the medium. We apply the model to study how stretch-activated currents affect the action potential shape, restitution properties, and dynamics of spiral waves, under constant stretch, and dynamic stretch caused by active mechanical contraction. We find that stretch conditions substantially affect these properties via stretch-activated currents. In constantly stretched medium, we observe a substantial decrease in conduction velocity, and an increase of action potential duration; whereas, with dynamic stretch, action potential duration is increased only slightly, and the conduction velocity restitution curve becomes biphasic. Moreover, in constantly stretched medium, we find an increase of the core size and period of a spiral wave, but no change in rotation dynamics; in contrast, in the dynamically stretching medium, we observe spiral drift. Our results may be important to understand how altered stretch conditions affect the heart's functioning.

  9. A discrete electromechanical model for human cardiac tissue: effects of stretch-activated currents and stretch conditions on restitution properties and spiral wave dynamics.

    Directory of Open Access Journals (Sweden)

    Louis D Weise

    Full Text Available We introduce an electromechanical model for human cardiac tissue which couples a biophysical model of cardiac excitation (Tusscher, Noble, Noble, Panfilov, 2006 and tension development (adjusted Niederer, Hunter, Smith, 2006 model with a discrete elastic mass-lattice model. The equations for the excitation processes are solved with a finite difference approach, and the equations of the mass-lattice model are solved using Verlet integration. This allows the coupled problem to be solved with high numerical resolution. Passive mechanical properties of the mass-lattice model are described by a generalized Hooke's law for finite deformations (Seth material. Active mechanical contraction is initiated by changes of the intracellular calcium concentration, which is a variable of the electrical model. Mechanical deformation feeds back on the electrophysiology via stretch-activated ion channels whose conductivity is controlled by the local stretch of the medium. We apply the model to study how stretch-activated currents affect the action potential shape, restitution properties, and dynamics of spiral waves, under constant stretch, and dynamic stretch caused by active mechanical contraction. We find that stretch conditions substantially affect these properties via stretch-activated currents. In constantly stretched medium, we observe a substantial decrease in conduction velocity, and an increase of action potential duration; whereas, with dynamic stretch, action potential duration is increased only slightly, and the conduction velocity restitution curve becomes biphasic. Moreover, in constantly stretched medium, we find an increase of the core size and period of a spiral wave, but no change in rotation dynamics; in contrast, in the dynamically stretching medium, we observe spiral drift. Our results may be important to understand how altered stretch conditions affect the heart's functioning.

  10. Glare Spot Phase Doppler Anemometry

    Science.gov (United States)

    Hespel, Camille; Ren, Kuanfang; Gréhan, Gérard; Onofri, Fabrice

    2007-06-01

    The Phase Doppler anemometry has been developed to measure simultaneously the velocity and the size of droplets. The measurement of the refractive index would be also interesting since it depends on the temperature and the composition of the particle and its measurement permits both to increase the quality of the diameter measurement and to obtain information on the temperature and/or the composition of the droplets. In this paper, we introduce a Glare Spot Phase Doppler Anemometry which uses two large beams. In this case, the images of the particle formed by the reflected and refracted light, known as glare spots, are separated in space. When a particle passes in the probe volume, the two parts in a signal obtained by a detector in forward direction are then separated in time. If two detectors are used the phase differences between two signals, the distance and the intensity ratio of reflected and refracted parts can be obtained and they provide rich information about the particle diameter and its refractive index, as well as its velocity. This paper is devoted to the numerical study of such a configuration with two theoretical models: geometrical optics and rigorous electromagnetism solution.

  11. The development of a combined b-mode, ARFI, and spectral Doppler ultrasound imaging system for investigating cardiovascular stiffness and hemodynamics

    Science.gov (United States)

    Doherty, Joshua R.; Dumont, Douglas M.; Trahey, Gregg E.

    2011-03-01

    The progression of atherosclerotic disease, caused by the formation of plaques within arteries, is a complex process believed to be a function of the localized mechanical properties and hemodynamic loading associated with the arterial wall. It is hypothesized that measurements of vascular stiffness and wall-shear rate (WSR) may provide important information regarding vascular remodeling, endothelial function, and the growth of soft-lipid filled plaques that could help a clinician better diagnose a patient's risk of clinical events such as stroke. To that end, the approach taken in this work was to combine conventional B-mode, Acoustic Radiation Force Impulse (ARFI), Shear Wave Elasticity Imaging (SWEI), and spectral Doppler techniques into a single imaging system capable of simultaneously measuring the tissue displacements and WSR throughout the cardiac cycle and over several heartbeats. Implemented on a conventional scanner, the carotid arteries of human subjects were scanned to demonstrate the initial in vivo feasibility of the method. Two non-invasive ultrasound based imaging methods, SAD-SWEI and SAD-Gated Imaging, were developed that measure ARF-induced on-axis tissue displacements, off-axis transverse wave velocities, and WSR throughout the cardiac cycle. Human carotid artery scans were performed in vivo on 5 healthy subjects. Statistical differences were observed in both on-axis proximal wall displacements and transverse wave velocities during diastole compared to systole.

  12. Endosonographic and color doppler flow imaging alterations observed within irradiated rectal cancer

    International Nuclear Information System (INIS)

    Alexander, Archie A.; Palazzo, Juan P.; Ahmad, Neelofur R.; Liu, J.-B.; Forsberg, Flemming; Marks, John

    1996-01-01

    Purpose: To correlate the endosonographic and color Doppler flow imaging alterations observed in irradiated rectal cancers with the pathologic features of radiation response, and to evaluate the potential impact of altered blood flow on the integrity of the surgical anastamosis. Methods and Materials: Endosonography with color and pulsed wave Doppler was performed on 20 rectal cancer masses before and after high dose preoperative radiation (XRT). Pre- and post-XRT observations included comparing alterations in tumor size, sonographic echotexture, color Doppler flow, and pulsatility indices. Comparisons were made with pathologic findings in the irradiated specimens and with the incidence of anastomotic failure. Results: Compared to pre-XRT observations, irradiated rectal cancers decreased in size and became either mixed in echogenicity with less apparent color Doppler flow (16 of 20) or unchanged in color Doppler flow and echotexture (4 of 20). Those with less flow (16 of 20) were imaged later (mean = 90.2 ± 12.1 days) than those without change in color Doppler flow (mean = 21.7 ± 2.7 days). Pathologically, the group of four without change in color Doppler signal had features of acute inflammation which were not observed in 16 of 20 imaged later. Based on pulsatility index measurements, both high and low resistance vessels were detected and confirmed by immunohistochemical staining, and features of postradiation obliterative vasculitis were observed. Only one primary anastomosis in 14 patients with decreased flow failed. Conclusions: The sonographic and color Doppler flow imaging alterations observed within irradiated rectal cancer correlated with changes of postradiation obliterative vasculitis. The apparent diminished local blood flow within high and low resistance vessels post-XRT did not result in an increased incidence of anastomotic failures

  13. An ocean current inversion accuracy analysis based on a Doppler spectrum model

    Institute of Scientific and Technical Information of China (English)

    BAO Qingliu; ZHANG Youguang; LIN Mingsen; GONG Peng

    2017-01-01

    Microwave remote sensing is one of the most useful methods for observing the ocean parameters.The Doppler frequency or interferometric phase of the radar echoes can be used for an ocean surface current speed retrieval,which is widely used in spaceborne and airborne radars.While the effect of the ocean currents and waves is interactional.It is impossible to retrieve the ocean surface current speed from Doppler frequency shift directly.In order to study the relationship between the ocean surface current speed and the Doppler frequency shift,a numerical ocean surface Doppler spectrum model is established and validated with a reference.The input parameters of ocean Doppler spectrum include an ocean wave elevation model,a directional distribution function,and wind speed and direction.The suitable ocean wave elevation spectrum and the directional distribution function are selected by comparing the ocean Doppler spectrum in C band with an empirical geophysical model function (CDOP).What is more,the error sensitivities of ocean surface current speed to the wind speed and direction are analyzed.All these simulations are in Ku band.The simulation results show that the ocean surface current speed error is sensitive to the wind speed and direction errors.With VV polarization,the ocean surface current speed error is about 0.15 m/s when the wind speed error is 2 m/s,and the ocean surface current speed error is smaller than 0.3 m/s when the wind direction error is within 20° in the cross wind direction.

  14. Radar Doppler Processing with Nonuniform Sampling.

    Energy Technology Data Exchange (ETDEWEB)

    Doerry, Armin W. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Conventional signal processing to estimate radar Doppler frequency often assumes uniform pulse/sample spacing. This is for the convenience of t he processing. More recent performance enhancements in processor capability allow optimally processing nonuniform pulse/sample spacing, thereby overcoming some of the baggage that attends uniform sampling, such as Doppler ambiguity and SNR losses due to sidelobe control measures.

  15. Gravitational wave searches using the DSN (Deep Space Network)

    International Nuclear Information System (INIS)

    Nelson, S.J.; Armstrong, J.W.

    1988-01-01

    The Deep Space Network Doppler spacecraft link is currently the only method available for broadband gravitational wave searches in the 0.01 to 0.001 Hz frequency range. The DSN's role in the worldwide search for gravitational waves is described by first summarizing from the literature current theoretical estimates of gravitational wave strengths and time scales from various astrophysical sources. Current and future detection schemes for ground based and space based detectors are then discussed. Past, present, and future planned or proposed gravitational wave experiments using DSN Doppler tracking are described. Lastly, some major technical challenges to improve gravitational wave sensitivities using the DSN are discussed

  16. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR......After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  17. Sub-Doppler cooling in reduced-period optical lattice geometries

    International Nuclear Information System (INIS)

    Berman, P.R.; Raithel, G.; Zhang, R.; Malinovsky, V.S.

    2005-01-01

    It is shown that sub-Doppler cooling occurs in an atom-field geometry that can lead to reduced-period optical lattices. Four optical fields are combined to produce a 'standing wave' Raman field that drives transitions between two ground state sublevels. In contrast to conventional Sisyphus cooling, sub-Doppler cooling to zero velocity occurs when all fields are polarized in the same direction. Solutions are obtained using both semiclassical and quantum Monte Carlo methods in the case of exact two-photon resonance. The connection of the results with conventional Sisyphus cooling is established using a dressed state basis

  18. Evaluating the cardiac function of duchenne muscular dystrophy with Doppler Tei index

    International Nuclear Information System (INIS)

    Yao Fengjuan; Zheng Ju; Lu Kun; Liu Donghong; Wu Miaoling; Lin Hong; Zhang Cheng; Yu Hongkui

    2007-01-01

    Objective: To evaluate the cardiac function of early Duchenne muscular dystrophy (DMD) by left ventricular ejection fraction (LVEF) and pulse Doppler Tei index. Methods: Twenty-eight DMD patients and fifteen normal people were studied. LVEF, E/A and Tei index were measured and calculated by M-mode and Pulse wave Doppler respectively. Results: Compared with control group, Tei index and IRT were significantly high, and there were not significant difference in LVEF(%) and E/A. Conclusion: Tei index was valuable in assessing cardiac function of early DMD. (authors)

  19. Gestational trophoblastic neoplasia: efficacy of color doppler ultrasound

    International Nuclear Information System (INIS)

    Song, Sun Wha; Jee, Won Hee; Choe, Bo Young; Byun, Jae Young; Choi, Byung Gil; Shinn, Kyung Sub

    1997-01-01

    To evaluate the efficacy of color Doppler ultrasound (US) in the diagnosis of gestational trophoblastic neoplasia (GTN). Intralesional color flows and resistive index (RI) on color Doppler US were prospectively analyzed in 21 consecutive suspected GTN cases. RI of the intralesional artery was investigated on the basis of the presence or absence of mass and metastasis. Correlation between RI of intralesional artery and urinary β-hCG was also investigated. Intralesional color flows were identified in 15 patients with GTN. On operation, intralesional color flows were observed in one of two patients in whom the presence of completely necrotic tissue was confirmed. Intralesional color flows, however, were not detected in four patients who were proved not to be GTN sufferers. Sensitivity, specificity, accuracy, positive and negative predictive values, and accuracy were 100%, 83%, 95%, 94% and 100%, respectively. Significant correlation between RI of the intralesional artery and urinary β-hCG was not established (p=0.49, r=0.19). RI of this artery was not substantially different between groups with and without mass, and between groups with and without metastasis (p=0.32, p=0.82). The current study demonstrates that color Doppler US is a sensitive and useful method for the diagnosis of GTN

  20. A Wearable Transcranial Doppler Ultrasound Phased Array System.

    Science.gov (United States)

    Pietrangelo, Sabino J; Lee, Hae-Seung; Sodini, Charles G

    2018-01-01

     Practical deficiencies related to conventional transcranial Doppler (TCD) sonography have restricted its use and applicability. This work seeks to mitigate several such constraints through the development of a wearable, electronically steered TCD velocimetry system, which enables noninvasive measurement of cerebral blood flow velocity (CBFV) for monitoring applications with limited operator interaction. A highly-compact, discrete prototype system was designed and experimentally validated through flow phantom and preliminary human subject testing. The prototype system incorporates a custom two-dimensional transducer array and multi-channel transceiver electronics, thereby facilitating acoustic beamformation via phased array operation. Electronic steering of acoustic energy enables algorithmic system controls to map Doppler power throughout the tissue volume of interest and localize regions of maximal flow. Multi-focal reception permits dynamic vessel position tracking and simultaneous flow velocimetry over the time-course of monitoring. Experimental flow phantom testing yielded high correlation with concurrent flowmeter recordings across the expected range of physiological flow velocities. Doppler power mapping has been validated in both flow phantom and preliminary human subject testing, resulting in average vessel location mapping times testing. A wearable prototype CBFV measurement system capable of autonomous vessel search and tracking has been presented. Although flow phantom and preliminary human validation show promise, further human subject testing is necessary to compare velocimetry data against existing commercial TCD systems. Additional human subject testing must also verify acceptable vessel search and tracking performance under a variety of subject populations and motion dynamics-such as head movement and ambulation.

  1. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  2. Value of dobutamine stress tissue Doppler in evaluation of LV ...

    African Journals Online (AJOL)

    Shaimaa Ahmed Mostafa

    2014-12-12

    Dec 12, 2014 ... Prediction of functional recovery, based on the detection of contractile reserve with dobutamine stress echocardiography. (DSE), includes myocardial perfusion imaging, metabolic imaging with conventional scintigraphy and positron emission tomography (PET).12. Dobutamine stress echocardiography is ...

  3. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  4. A model for post-occlusive reactive hyperemia as measured with laser-Doppler perfusion monitoring

    NARCIS (Netherlands)

    de Mul, FFM; Morales, F; Smit, AJ; Graaff, R

    To facilitate the quantitative analysis of post-occlusive reactive fiyper emia (POR11), measured with laser-Doppler perfusion monitoring (LDPM) on extremities, we present a flow model for the dynamics of the perfusion of the tissue during PORH, based on three parameters: two time constants (tau(1)

  5. Detection of Moving Targets Based on Doppler Spectrum Analysis Technique for Passive Coherent Radar

    Directory of Open Access Journals (Sweden)

    Zhao Yao-dong

    2013-06-01

    Full Text Available A novel method of moving targets detection taking Doppler spectrum analysis technique for Passive Coherent Radar (PCR is provided. After dividing the receiving signals into segments as pulse series, it utilizes the technique of pulse compress and Doppler processing to detect and locate the targets. Based on the algorithm for Pulse-Doppler (PD radar, the equipollence between continuous and pulsed wave in match filtering is proved and details of this method are introduced. To compare it with the traditional method of Cross-Ambiguity Function (CAF calculation, the relationship and mathematical modes of them are analyzed, with some suggestions on parameters choosing. With little influence to the gain of targets, the method can greatly promote the processing efficiency. The validity of the proposed method is demonstrated by offline processing real collected data sets and simulation results.

  6. Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse

    Science.gov (United States)

    Adair, Henry S., III

    1998-07-01

    Current methods for in vivo evaluation of digital hemodynamics in the horse include angiography, scintigraphy, Doppler ultrasound, electromagnetic flow and isolated extracorporeal pump perfused digit preparations. These techniques are either non-quantifiable, do not allow for continuous measurement, require destruction of the horse orare invasive, inducing non- physiologic variables. In vitro techniques have also been reported for the evaluation of the effects of vasoactive agents on the digital vessels. The in vitro techniques are non-physiologic and have evaluated the vasculature proximal to the coronary band. Lastly, many of these techniques require general anesthesia or euthanasia of the animal. Laser Doppler flowmetry is a non-invasive, continuous measure of capillary blood flow. Laser Doppler flowmetry has been used to measure capillary blood flow in many tissues. The principle of this method is to measure the Doppler shift, that is, the frequency change that light undergoes when reflected by moving objects, such as red blood cells. Laser Doppler flowmetry records a continuous measurement of the red cell motion in the outer layer of the tissue under study, with little or no influence on physiologic blood flow. This output value constitutes the flux of red cells and is reported as capillary perfusion units. No direct information concerning oxygen, nutrient or waste metabolite exchange in the surrounding tissue is obtained. The relationship between the flowmeter output signal and the flux of red blood cells is linear. The principles of laser Doppler flowmetry will be discussed and the technique for laminar capillary blood flow measurements will be presented.

  7. Wave Tank Studies of Phase Velocities of Short Wind Waves

    Science.gov (United States)

    Ermakov, S.; Sergievskaya, I.; Shchegolkov, Yu.

    Wave tank studies of phase velocities of short wind waves have been carried out using Ka-band radar and an Optical Spectrum Analyser. The phase velocities were retrieved from measured radar and optical Doppler shifts, taking into account measurements of surface drift velocities. The dispersion relationship was studied in centimetre (cm)- and millimetre(mm)-scale wavelength ranges at different fetches and wind speeds, both for a clean water surface and for water covered with surfactant films. It is ob- tained that the phase velocities do not follow the dispersion relation of linear capillary- gravity waves, increasing with fetch and, therefore, depending on phase velocities of dominant decimetre (dm)-centimetre-scale wind waves. One thus can conclude that nonlinear cm-mm-scale harmonics bound to the dominant wind waves and propagat- ing with the phase velocities of the decimetric waves are present in the wind wave spectrum. The resulting phase velocities of short wind waves are determined by re- lation between free and bound waves. The relative intensity of the bound waves in the spectrum of short wind waves is estimated. It is shown that this relation depends strongly on the surfactant concentration, because the damping effect due to films is different for free and bound waves; this results to changes of phase velocities of wind waves in the presence of surfactant films. This work was supported by MOD, UK via DERA Winfrith (Project ISTC 1774P) and by RFBR (Project 02-05-65102).

  8. Hydronephrosis and pregnancy: study with Doppler echography. Hidronefrosis y embarazo: estudio mediante ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Ripolles Gonzalez, T.R.; Ambit Capdevilla, S.; Sanguesa Nebot, C.; Lazaro, S. de; Garcia Vila, J.H.; Belloch Ugarte, V.

    1993-01-01

    An 18-month study was performed to establish the normal intrarenal resistance index during pregnancy, in order to determine whether it differed significantly depending on the week of gestation or the degree of hydronephrosis. For this purpose , the flow velocity waves obtained in right kidney were analyzed in a group of 112 patients on the basis of 209 explorations. The kidneys were classified as grade 0,I,II, or III according to the degree of hydronephrosis. Doppler signal sampling was carried out at the level of the corticomedullary junction. From the results of the study it can be deduced that the index of intrarenal resistance during pregnancy is similar to that of the general population, that there are no significant differences among the groups with different degree of hydronephrosis and that the index does not vary according to the different weeks of gestation. These findings suggest that, during pregnancy, a pathological resistance index in a kidney should not be attributed to the physiological changes associated with normal gestation. (Author) 21 refs.

  9. Developing de Broglie Wave

    Directory of Open Access Journals (Sweden)

    Zheng-Johansson J. X.

    2006-10-01

    Full Text Available The electromagnetic component waves, comprising together with their generating oscillatory massless charge a material particle, will be Doppler shifted when the charge hence particle is in motion, with a velocity v, as a mere mechanical consequence of the source motion. We illustrate here that two such component waves generated in opposite directions and propagating at speed c between walls in a one-dimensional box, superpose into a traveling beat wave of wavelength Λd=vcΛ and phase velocity c2/v+v which resembles directly L. de Broglie’s hypothetic phase wave. This phase wave in terms of transmitting the particle mass at the speed v and angular frequency Ωd= 2πv/Λd, with Λd and Ωd obeying the de Broglie relations, represents a de Broglie wave. The standing-wave function of the de Broglie (phase wave and its variables for particle dynamics in small geometries are equivalent to the eigen-state solutions to Schrödinger equation of an identical system.

  10. Noncoherent Doppler tracking: first flight results

    Science.gov (United States)

    DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.

    2005-01-01

    Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.

  11. Doppler coefficient measurements in Zebra Core 5

    International Nuclear Information System (INIS)

    Baker, A.R.; Wheeler, R.C.

    1965-11-01

    Measurements using a central hot loop in Zebra Core 5 are described. Results are given for the Doppler coefficients found in a number of assemblies with PuO 2 and 16% PuO 2 /84% depleted UO 2 pins, loaded with different combinations of steel, sodium or void pins. The mixed oxide results are in general about 20% more negative than was calculated using the FD2 data set, but agreement is good if the plutonium contributions in the calculations are omitted. The small positive Doppler coefficient calculated for Pu239 was not observed, and two measurements indicated instead a small negative effect. The Doppler effect in the mixed oxide systems was found to vary approximately as 1/T. The results from the empty loop and non-fissile assemblies indicate either a small negative Doppler effect in steel or alternatively the presence of an unexplained expansion effect. (author)

  12. Spectral Doppler findings in a rare case of acute compartment syndrome following leg burn

    Directory of Open Access Journals (Sweden)

    Omer A. Mahmoud

    2018-04-01

    Full Text Available Acute compartment syndrome (ACS is an orthopedic emergency condition, which is rarely attributed to burns. It occurs when pressure in an enclosed space rises to a point where it reduces blood flow and impairs tissue perfusion. Its consequences often lead to ischemia and possible necrosis within that space. Until now, the use of Doppler assessment to explore different types of compartment syndrome has yielded contradictory findings. Here, we present a significant increase of blood flow velocity in the arteries proximal to the burned area. Thus, the combination of Duplex ultrasound results with clinical findings will help vascular surgeons to make immediate decision to perform fasciotomy. Keywords: Compartment syndrome, Spectral Doppler

  13. Applications of Doppler in the first trimester

    International Nuclear Information System (INIS)

    Taylor, K.J.W.; Ramirez, B.; Grannum, P.

    1986-01-01

    Fifty patients have been studied by duplex Doppler US imaging in the first trimester. In normal gestations, luteal flow, characterized by a low pulsatility index (PI), can be seen in at least one ovary. Failure to detect luteal flow indicates a nonviable pregnancy. Six ectopic pregnancies demonstrated luteal flow and extrauterine heartbeat, detected by Doppler US. High PI values in the uterine artery are seen in the first trimester. Low PI values in the uterine arteries were found in patients with trophoblastic disease

  14. De-Dopplerization of Acoustic Measurements

    Science.gov (United States)

    2017-08-10

    accurate measurement of aircraft location to resample the time signal to account for the compression and expansion of acoustic wavefronts. Correcting...AFRL-RH-WP-TR-2017-0043 DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS Frank Mobley, PhD 711 HPW/RHCB Wright-Patterson AFB OH...TITLE AND SUBTITLE DE-DOPPLERIZATION OF ACOUSTIC MEASUREMENTS 5a. CONTRACT NUMBER In-House 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER

  15. The Role of Color Doppler Ultrasonography in Characterization of Thyroid Tumors

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Jeon, Pyong; Won, Jong Yoon; Na, Jae Beom; Lee, Hyang Mee; Yoo, Hyung Sik; Lee, Jong Tae; Park, Jeong Soo; Cho, Nam Hoon

    1995-01-01

    To assess the usefulness of color Doppler ultrasonography in the characterization of thyroid tumors, surgically proven 88 nodules in 85 patients were evaluated. Using 10 MHz linear array transducer, gray scale images were initially evaluated. Then, distribution pattern of color signals (marginal, intra-tumoral, mixed) and graded internal vascularity according to morphology of color signal (0:absence of internal signal, 1: spotty, 2: linear,3: branching) were observed on color doppler imaging. Pulsed doppler waves were analyzed with parameters including peak systolic velocity(PSV), resistive index(RI), and pulsatile index(PI). Significantly larger numbers of intra-tumoral type, 20 cases(62.5%), were observed in malignant nodules, whereas mixed forms were predominant in benign group, 37 cases (66%) In graded internal vascularity, malignant nodules tended to have grade 2 or 3 signals, whereas benign nodules tended to have grade 0 or 1 signals. Spectral wave analysis show no significant difference in the value of PSV, RI, and PI between malignancy and benignity group. In conclusion, color Doppler imaging has a potential role in the characterization of thyroid nodules as a supportive method for gray scale diagnosis

  16. Technical Note: A new phantom design for routine testing of Doppler ultrasound.

    Science.gov (United States)

    Grice, J V; Pickens, D R; Price, R R

    2016-07-01

    The objective of this project is to demonstrate the principle and operation for a simple, inexpensive, and highly portable Doppler ultrasound quality assurance (QA) phantom intended for routine QA testing. A prototype phantom has been designed, fabricated, and evaluated. The phantom described here is powered by gravity alone, requires no external equipment for operation, and produces a stable fluid velocity useful for quality assurance. Many commercially available Doppler ultrasound testing systems can suffer from issues such as a lengthy setup, prohibitive cost, nonportable size, or difficulty in use. This new phantom design aims to address some of these problems and create a phantom appropriate for assessing Doppler ultrasound stability. The phantom was fabricated using a 3D printer. The basic design of the phantom is to provide gravity-powered flow of a Doppler fluid between two reservoirs. The printed components were connected with latex tubing and then seated in a tissue mimicking gel. Spectral Doppler waveforms were sampled to evaluate variations in the data, and the phantom was evaluated using high frame rate video to find an alternate measure of mean fluid velocity flowing in the phantom. The current system design maintains stable flow from one reservoir to the other for approximately 7 s. Color Doppler imaging of the phantom was found to be qualitatively consistent with laminar flow. Using pulsed spectral Doppler, the average fluid velocity from a sample volume approximately centered in the synthetic vessel was measured to be 56 cm/s with a standard deviation of 3.2 cm/s across 118 measurements. An independent measure of the average fluid velocity was measured to be 51.9 cm/s with a standard deviation of 0.7 cm/s over 4 measurements. The developed phantom provides stable fluid flow useful for frequent clinical Doppler ultrasound testing and attempts to address several obstacles facing Doppler phantom testing. Such an ultrasound phantom can make routine

  17. Power Doppler sonography and ultrasound contrast agent in assessing rheumatoid synovitis

    Directory of Open Access Journals (Sweden)

    F. Salaffi

    2011-09-01

    Full Text Available Pannus formation is a fundamental event in the pathogenesis of rheumatoid arthritis and its hypervascularisation seems to be crucial to the development of joint damage. High-resolution greyscale ultrasonography is a safe, quick, and inexpensive imaging tool that allows an accurate detection of even minimal morphostructural changes in patients with rheumatoid arthritis, including joint effusion, thickening of synovial membrane and bone erosions. More recently, power Doppler sonography has proved to be a reliable tool for semiquantitative assessment of the vascularity of the synovial tissue. The contrast-enhanced power Doppler sonography seems to be a helpful adjunct in assessing synovitis and the therapeutic response to the different therapies in patients with rheumatoid arthritis. The aim of this radiological vignette was to show a representative example of use of power Doppler sonography with contrast agent in assessing rheumatoid synovitis.

  18. In-vivo imaging of blood flow in human retinal vessels using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    1999-04-01

    Quantification of retinal blood flow may lead to a better understanding of the progression and treatment of several ocular disorders, including diabetic retinopathy, age- related macular degeneration, and glaucoma. Current techniques, such as fluorescein angiography and laser Doppler velocimetry are limited, failing to provide sufficient information to the clinician. Color Doppler optical coherence tomography (CDOCT) is a novel technique using coherent heterodyne detection for simultaneous cross- sectional imaging of tissue microstructure and blood flow. This technique is capable of high spatial and velocity resolution imaging in highly scattering media. We implemented CDOCT for retinal blood flow mapping in human subjects. No dilation of the pupil was necessary. CDOCT is demonstrated for determining bidirectional flow in sub- 100micrometers diameter vessels in the retina. Additionally, we calculated Doppler broadening using the variance of depth- resolved spectra to identify regions with large velocity gradients within the Xenopus heart. This technique may be useful in quantifying local tissue perfusion in highly vascular retinal tissue.

  19. Modeling of Doppler frequency shift in multipath radio channels

    Directory of Open Access Journals (Sweden)

    Penzin M.S.

    2016-06-01

    Full Text Available We discuss the modeling of propagation of a quasi-monochromatic radio signal, represented by a coherent pulse sequence, in a non-stationary multipath radio channel. In such a channel, signal propagation results in the observed frequency shift for each ray (Doppler effect. The modeling is based on the assumption that during propagation of a single pulse a channel can be considered stationary. A phase variation in the channel transfer function is shown to cause the observed frequency shift in the received signal. Thus, instead of measuring the Doppler frequency shift, we can measure the rate of variation in the mean phase of one pulse relative to another. The modeling is carried out within the framework of the method of normal waves. The method enables us to model the dynamics of the electromagnetic field at a given point with the required accuracy. The modeling reveals that a local change in ionospheric conditions more severely affects the rays whose reflection region is in the area where the changes occur.

  20. Numerical study of glare spot phase Doppler anemometry

    Science.gov (United States)

    Hespel, C.; Ren, K. F.; Gréhan, G.; Onofri, F.

    2008-03-01

    The phase Doppler anemometry has (PDA) been developed to measure simultaneously the velocity and the size of droplets. When the concentration of particles is high, tightly focused beams must be used, as in the dual burst PDA. The latter permits an access to the refractive index of the particle, but the effect of wave front curvature of the incident beams becomes evident. In this paper, we introduce a glare spot phase Doppler anemometry which uses two large beams. The images of the particle formed by the reflected and refracted light, known as glare spots, are separated in space. When a particle passes through the probe volume, the two parts in a signal obtained by a detector in forward direction are then separated in time. If two detectors are used the phase differences and the intensity ratios between two signals, the distance between the reflected and refracted spots can be obtained. These measured values provide information about the particle diameter and its refractive index, as well as its two velocity components. This paper is devoted to the numerical study of such a configuration with two theoretical models: geometrical optics and rigorous electromagnetism solution.

  1. Current status of musculoskeletal application of shear wave elastography

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Jeong Ah [Dept. of Radiology, Hanyang University Guri Hospital, Hanyang University School of Medicine, Guri (Korea, Republic of); Jeong, Woo Kyoung [Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-07-15

    Ultrasonography (US) is a very powerful diagnostic modality for the musculoskeletal system due to the ability to perform real-time dynamic high-resolution examinations with the Doppler technique. In addition to acquiring morphologic data, we can now obtain biomechanical information by quantifying the elasticity of the musculoskeletal structures with US elastography. The earlier diagnosis of degeneration and the ability to perform follow-up evaluations of healing and the effects of treatment are possible. US elastography enables a transition from US-based inspection to US-based palpation in order to diagnose the characteristics of tissue. Shear wave elastography is considered the most suitable type of US elastography for the musculoskeletal system. It is widely used for tendons, ligaments, and muscles. It is important to understand practice guidelines in order to enhance reproducibility. Incorporating viscoelasticity and overcoming inconsistencies among manufacturers are future tasks for improving the capabilities of US elastography.

  2. Current status of musculoskeletal application of shear wave elastography

    Directory of Open Access Journals (Sweden)

    JeongAh Ryu

    2017-07-01

    Full Text Available Ultrasonography (US is a very powerful diagnostic modality for the musculoskeletal system due to the ability to perform real-time dynamic high-resolution examinations with the Doppler technique. In addition to acquiring morphologic data, we can now obtain biomechanical information by quantifying the elasticity of the musculoskeletal structures with US elastography. The earlier diagnosis of degeneration and the ability to perform follow-up evaluations of healing and the effects of treatment are possible. US elastography enables a transition from US-based inspection to US-based palpation in order to diagnose the characteristics of tissue. Shear wave elastography is considered the most suitable type of US elastography for the musculoskeletal system. It is widely used for tendons, ligaments, and muscles. It is important to understand practice guidelines in order to enhance reproducibility. Incorporating viscoelasticity and overcoming inconsistencies among manufacturers are future tasks for improving the capabilities of US elastography.

  3. Current status of musculoskeletal application of shear wave elastography

    International Nuclear Information System (INIS)

    Ryu, Jeong Ah; Jeong, Woo Kyoung

    2017-01-01

    Ultrasonography (US) is a very powerful diagnostic modality for the musculoskeletal system due to the ability to perform real-time dynamic high-resolution examinations with the Doppler technique. In addition to acquiring morphologic data, we can now obtain biomechanical information by quantifying the elasticity of the musculoskeletal structures with US elastography. The earlier diagnosis of degeneration and the ability to perform follow-up evaluations of healing and the effects of treatment are possible. US elastography enables a transition from US-based inspection to US-based palpation in order to diagnose the characteristics of tissue. Shear wave elastography is considered the most suitable type of US elastography for the musculoskeletal system. It is widely used for tendons, ligaments, and muscles. It is important to understand practice guidelines in order to enhance reproducibility. Incorporating viscoelasticity and overcoming inconsistencies among manufacturers are future tasks for improving the capabilities of US elastography

  4. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  5. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  6. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  7. Remote effects of extracorporeal shock wave therapy on cutaneous microcirculation.

    Science.gov (United States)

    Kisch, Tobias; Sorg, Heiko; Forstmeier, Vinzent; Knobloch, Karsten; Liodaki, Eirini; Stang, Felix; Mailänder, Peter; Krämer, Robert

    2015-11-01

    Extracorporeal shock wave treatment (ESWT) has proven its clinical benefits in different fields of medicine. Tissue regeneration and healing is improved after shock wave treatment. Even in the case of burn wounds angiogenesis and re-epithelialization is accelerated, but ESWT in extensive burn wounds is impracticable. High energy ESWT influences cutaneous microcirculation at body regions remote from application site. Eighteen Sprague Dawley rats were randomly assigned to two groups and received either high energy ESWT (Group A: total 1000 impulses, 10 J) or placebo shock wave treatment (Group B: 0 impulses, 0 J), applied to the dorsal lower leg of the hind limb. Ten minutes later microcirculatory effects were assessed at the contralateral lower leg of the hind limb (remote body region) by combined Laser-Doppler-Imaging and Photospectrometry. In Group A cutaneous capillary blood velocity was significantly increased by 152.8% vs. placebo ESWT at the remote body location (p = 0.01). Postcapillary venous filling pressure remained statistically unchanged (p > 0.05), while cutaneous tissue oxygen saturation increased by 12.7% in Group A (p = 0.220). High energy ESWT affects cutaneous hemodynamics in body regions remote from application site in a standard rat model. The results of this preliminary study indicate that ESWT might be beneficial even in disseminated and extensive burn wounds by remote shock wave effects and should therefore be subject to further scientific evaluation. Copyright © 2015 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.

  8. Attenuated Vector Tomography -- An Approach to Image Flow Vector Fields with Doppler Ultrasonic Imaging

    International Nuclear Information System (INIS)

    Huang, Qiu; Peng, Qiyu; Huang, Bin; Cheryauka, Arvi; Gullberg, Grant T.

    2008-01-01

    The measurement of flow obtained using continuous wave Doppler ultrasound is formulated as a directional projection of a flow vector field. When a continuous ultrasound wave bounces against a flowing particle, a signal is backscattered. This signal obtains a Doppler frequency shift proportional to the speed of the particle along the ultrasound beam. This occurs for each particle along the beam, giving rise to a Doppler velocity spectrum. The first moment of the spectrum provides the directional projection of the flow along the ultrasound beam. Signals reflected from points further away from the detector will have lower amplitude than signals reflected from points closer to the detector. The effect is very much akin to that modeled by the attenuated Radon transform in emission computed tomography.A least-squares method was adopted to reconstruct a 2D vector field from directional projection measurements. Attenuated projections of only the longitudinal projections of the vector field were simulated. The components of the vector field were reconstructed using the gradient algorithm to minimize a least-squares criterion. This result was compared with the reconstruction of longitudinal projections of the vector field without attenuation. If attenuation is known, the algorithm was able to accurately reconstruct both components of the full vector field from only one set of directional projection measurements. A better reconstruction was obtained with attenuation than without attenuation implying that attenuation provides important information for the reconstruction of flow vector fields.This confirms previous work where we showed that knowledge of the attenuation distribution helps in the reconstruction of MRI diffusion tensor fields from fewer than the required measurements. In the application of ultrasound the attenuation distribution is obtained with pulse wave transmission computed tomography and flow information is obtained with continuous wave Doppler

  9. Six-beam homodyne laser Doppler vibrometry based on silicon photonics technology.

    Science.gov (United States)

    Li, Yanlu; Zhu, Jinghao; Duperron, Matthieu; O'Brien, Peter; Schüler, Ralf; Aasmul, Soren; de Melis, Mirko; Kersemans, Mathias; Baets, Roel

    2018-02-05

    This paper describes an integrated six-beam homodyne laser Doppler vibrometry (LDV) system based on a silicon-on-insulator (SOI) full platform technology, with on-chip photo-diodes and phase modulators. Electronics and optics are also implemented around the integrated photonic circuit (PIC) to enable a simultaneous six-beam measurement. Measurement of a propagating guided elastic wave in an aluminum plate (speed ≈ 909 m/s @ 61.5 kHz) is demonstrated.

  10. A review of results of the international ionospheric Doppler sounder network

    Czech Academy of Sciences Publication Activity Database

    Laštovička, Jan; Chum, Jaroslav

    2017-01-01

    Roč. 60, č. 8 (2017), s. 1629-1643 ISSN 0273-1177 R&D Projects: GA ČR(CZ) GC15-07281J Institutional support: RVO:68378289 Keywords : ionospheric Doppler shift sounding * gravity waves * infrasound * solar forcing Subject RIV: DG - Athmosphere Sciences, Meteorology OBOR OECD: Meteorology and atmospheric sciences Impact factor: 1.401, year: 2016 http://www.sciencedirect.com/science/article/pii/S0273117717300790?via%3Dihub

  11. Direct measurement of Lorentz transformation with Doppler effects

    Science.gov (United States)

    Chen, Shao-Guang

    For space science and astronomy the fundamentality of one-way velocity of light (OWVL) is selfevident. The measurement of OWVL (distance/interval) and the clock synchronization with light-signal transfer make a logical circulation. This means that OWVL could not be directly measured but only come indirectly from astronomical method (Romer's Io eclipse and Bradley's sidereal aberration), furthermore, the light-year by definitional OWVL and the trigonometry distance with AU are also un-measurable. For to solve this problem two methods of clock synchronization were proposed: The direct method is that at one end of dual-speed transmissionline with single clock measure the arriving-time difference of longitudinal wave and transverse wave or ordinary light and extraordinary light, again to calculate the collective sending-time of two wave with Yang's /shear elastic-modulus ratio (E/k) or extraordinary/ordinary light refractive-index ratio (ne/no), which work as one earthquake-station with single clock measures first-shake time and the distance to epicenter; The indirect method is that the one-way wavelength l is measured by dual-counters Ca and Cb and computer's real-time operation of reading difference (Nb - Na) of two counters, the frequency f is also simultaneously measured, then l f is just OWVL. Therefore, with classical Newtonian mechanics and ether wave optics, OWVL can be measured in the Galileo coordinate system with an isotropic length unit (1889 international meter definition). Without any hypotheses special relativity can entirely establish on the metrical results. When a certain wavelength l is defined as length unit, foregoing measurement of one-way wavelength l will become as the measurement of rod's length. Let a rigidity-rod connecting Ca and Cb moves relative to lamp-house with velocity v, rod's length L = (Nb - Na) l will change follow v by known Doppler effect, i.e., L(q) =L0 (1+ (v/c) cos q), where L0 is the proper length when v= 0, v• r = v cos q

  12. The impact of left ventricular preload reduction on cardiac pulsed doppler indices during hemodialysis and its relation to intra-dialysis hypotension: A pulsed doppler study

    International Nuclear Information System (INIS)

    Alarrayed, Sameer; Garadah Taysir Said; Alawdi, Abdulhai Ali

    2009-01-01

    Fluid status in the body plays an important role on left ventricular (LV) filling in patients with end-stage renal disease (ESRD) on regular hemodialysis (HD), and plays a role in intra-dialysis hemodynamic derangement. Fifty-two patients with ESRD on regular HD, including 34 males with a mean age of 45.5 +- 13 years (range 18-72 years), were studied. All patients underwent Echo-pulsed Doppler study before and immediately after a HD session. The Echo Doppler indices noted were: LV cavity dimension and wall thickness, LV ejection fraction (LVEF%), trans-mitral early diastolic filling velocity (E wave), atrial filling diastolic velocity (A wave), E/A ratio, Deceleration Time (DT) of E wave, Isovolumic relaxation time (IVRT), Aortic Velocity Integral (AVI) and Inferior Vena Cava Diameter (VCD) at expiration. Patients were divided into two groups according to the amount of net ultra filtrate loss after HD. Group I comprised of 25 patients with fluid loss of 2 liters. During the HD session, each patient was observed for the development of acute clinical events such as arterial hypotension (systolic BP less than 90 mmHg), chest pain and arrhythmias. There was a significant difference between the two groups in the mean values, pre- and post- HD, of reduction of E wave velocity (p < 0.01), the reduction of E/A ratio (p< 0.05), the increment in DT of E wave (p< 0.05), the reduction in AVI (p< 0.01) and the reduction of VCD (p< 0.05). There was no significant difference between the groups in the reduction of A wave velocity and the reduction of IVRT. Among the study patients, 11 (21%) developed systolic hypo-tension during HD. The pre-dialysis mean values of E/A ratio and DT of E wave in patients who developed hypotension compared to those who did not was 0.7 +- 0.2 vs 1.1 +- 0.2.1 (p< 0.001) and 246 +- 40 vs 224 +- 34 msec (p< 0.05), respectively. Our study suggests that preload reduction in patients with ESRD on regular HD is directly proportional to the reduction of left

  13. Radial shock wave treatment alone is less efficient than radial shock wave treatment combined with tissue-specific plantar fascia-stretching in patients with chronic plantar heel pain.

    Science.gov (United States)

    Rompe, Jan D; Furia, John; Cacchio, Angelo; Schmitz, Christoph; Maffulli, Nicola

    2015-12-01

    Whether shock wave therapy or shock wave therapy combined with plantar fascia-specific stretching is more efficient in treating chronic plantar heel pain remains unclear. The aim of the study was to test the null hypothesis of no difference of these two forms of management for patients who had unilateral plantar fasciopathy for a minimum duration of twelve months and which had failed at least three other forms of treatment. One hundred and fifty-two patients with chronic plantar fasciopathy were assigned to receive repetitive low-energy radial shock-wave therapy without local anesthesia, administered weekly for three weeks (Group 1, n = 73) or to receive the identical shock wave treatment and to perform an eight-week plantar fascia-specific stretching program (Group 2, n = 79). All patients completed the nine-item pain subscale of the validated Foot Function Index and a subject-relevant outcome questionnaire. Patients were evaluated at baseline, and at two, four, and twenty-four months after baseline. The primary outcome measures were a mean change in the Foot Function Index sum score at two months after baseline, a mean change in item 2 (pain during the first steps of walking in the morning) on this Index, and satisfaction with treatment. No difference in mean age, sex, weight or duration of symptoms was found between the groups at baseline. At two months after baseline, the Foot Function Index sum score showed significantly greater changes for the patients managed with shock-wave therapy plus plantar fascia-specific stretching than those managed with shock-wave therapy alone (p plantar fascia in combination with repetitive low-energy radial shock-wave therapy is more efficient than repetitive low-energy radial shock-wave therapy alone for the treatment of chronic symptoms of proximal plantar fasciopathy. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  14. MP3 compression of Doppler ultrasound signals.

    Science.gov (United States)

    Poepping, Tamie L; Gill, Jeremy; Fenster, Aaron; Holdsworth, David W

    2003-01-01

    The effect of lossy, MP3 compression on spectral parameters derived from Doppler ultrasound (US) signals was investigated. Compression was tested on signals acquired from two sources: 1. phase quadrature and 2. stereo audio directional output. A total of 11, 10-s acquisitions of Doppler US signal were collected from each source at three sites in a flow phantom. Doppler signals were digitized at 44.1 kHz and compressed using four grades of MP3 compression (in kilobits per second, kbps; compression ratios in brackets): 1400 kbps (uncompressed), 128 kbps (11:1), 64 kbps (22:1) and 32 kbps (44:1). Doppler spectra were characterized by peak velocity, mean velocity, spectral width, integrated power and ratio of spectral power between negative and positive velocities. The results suggest that MP3 compression on digital Doppler US signals is feasible at 128 kbps, with a resulting 11:1 compression ratio, without compromising clinically relevant information. Higher compression ratios led to significant differences for both signal sources when compared with the uncompressed signals. Copyright 2003 World Federation for Ultrasound in Medicine & Biology

  15. Editorial special issue on "Laser Doppler vibrometry"

    Science.gov (United States)

    Vanlanduit, Steve; Dirckx, Joris

    2017-12-01

    The invention of the laser in 1960 has opened up many opportunities in the field of measurement science and technology. Just a few years after the invention of the laser, a novel fluid flow measurement technique based on the Doppler effect was introduced: at that moment the laser Doppler anemometer or shortly LDA [1] was born. The technique enabled fluid velocity measurement by using the light of a He-Ne beam which was scattered by very small polystyrene spheres entrained in the fluid. Later on, in the late nineteen seventees it was recognized that the detection of the Doppler frequency shift that occurs when light is scattered by a moving surface can also be used to measure the vibration velocity of an object. The instrument to perform these vibration measurements was called the laser Doppler vibrometer or LDV [2]. In the last decades several technological advances were made in the field of laser Doppler vibrometry. The result is that nowadays, velocity measurements of fluids (using LDA) and vibrating objects (using LDV) are performed in many challenging applications in different fields (microelectronics, civil structures, biomedical engineering, material science, etc.).

  16. Fresh look at the doppler changes in pregnancies with placental-based complications

    Directory of Open Access Journals (Sweden)

    S Dikshit

    2011-01-01

    Full Text Available Placental-based complications of pregnancy can be classified as acute and chronic. An example of acute placental complication is abruptio placenta. The chronic placental complications include pregnancy induced hypertension (PIH and idiopathic Intrauterine growth restriction (IUGR. The fetus is at risk for perinatal complications in both acute and chronic conditions. Here we take a look at the natural history of the Doppler parameters in chronic conditions. The techniques used for assessing the fetal well-being include, clinical methods, biophysical tests, conventional ultrasonography, and fetal Doppler studies. Arterial Doppler studies are used to assess the well-being of the fetus and to determine the timing of delivery. However, arterial Dopplers predict only the subset of fetuses at risk of having perinatal complications. Venous Dopplers have been used to improve upon the prognostication. However, by the time the commonly used venous Doppler signs, that is, ′A′ wave reversal in ductus venosus (DV is present, the fetus is likely to be already compromised. The fetus tries to adapt to the environment of deprivation by making a series of changes in the umbilical artery circulation, cerebral circulation, and hepatic circulation. As a result of these adaptations, the fetus overcomes the state of chronic hypoxia. This article takes a look at these changes and also the effect of these adaptations. It is suggested that serial comparisons of the venous flow characteristics of the DV and inferior vena cava (IVC can provide an early indication of the impending decompensation and can be used to predict the time the delivery.

  17. The role of colour flow Doppler in the investigation of the salivary gland tumour

    International Nuclear Information System (INIS)

    Bradley, M.J.; Durham, L.H.; Lancer, J.M.

    2000-01-01

    AIMS: Ultrasound is a highly effective imaging technique to determine salivary gland tumours and may help to identify many benign lesions. The aim of this study is to evaluate whether colour Doppler is able to further differentiate the malignant tumour. METHODS: Fifty-six patients with salivary gland lesions were prospectively assessed using ultrasound imaging with colour flow and power Doppler. The peak systolic velocity (PSV) was measured and the pulsatility index (PI) and resistive index (RI) calculations were performed on the pulsed wave traces. The real time ultrasound morphology and the Doppler information were correlated with the histology. RESULTS: In 18 of the 56 patients, no internal colour flow or power Doppler changes could be detected. The real time ultrasound morphology diagnosed benign disease with sensitivity of 89.7% with specificity of 57.1%. The positive predictive value was 93.6%. There were no significant differences in the colour Doppler appearances in terms of vessel type or intratumour distribution which could separate benign from malignant conditions. However, there was statistical discrimination for PI and RI values (P = 0.0006, P = 0.0002, respectively). No malignant lesions were seen when the PI was less than 1.8 and RI was less than 0.8. The PSV was elevated in several cases (> 50 cm per s) but there was no statistical correlation with malignancy. CONCLUSION: The risk of malignancy increases by a third when the colour Doppler demonstrates increased intratumour vascular resistance (RI > 0.8 and PI > 1.8), with positive predictive value of 97.3% (sensitivity 75.5%, specificity 85.7%). Bradley, M.J. (2000). Clinical Radiology 55, 759-762

  18. Experimental verification of the inverse Doppler effect in negative-index material

    Science.gov (United States)

    Feng, Lie; Chen, Jiabi; Wang, Yan; Geng, Tao; Zhuang, Songlin

    2010-10-01

    μResearch of negative-index material (NIM) is a very hot developing research field in recent years. NIM is also called left-handed material (LHM), in which the electric field [see manuscript], the magnetic field [see manuscript] and the wave vector [see manuscript] are not composed of a set of right-handed coordinates but a set of left-handed coordinates. Thus the action of electromagnetic waves in both left-handed material and right-handed material is just the opposite, for instance, the negative refraction phenomenon, the inverse Doppler effect and so on. Here we report the explicit result of the inverse Doppler effect through a photonic crystal (PC) prism at 10.6m wavelength for the first time, and the result we get from the experiment is much similar to the theoretical analysis we have deduced before. During the experiment, the CO2 laser is used as a light source, and the PC prism is used as a sample, which can move a tiny distance (1mm) uniformly with a translating stage. Based on the method of optical heterodyne, we let the emergent light from the output surface of PC prism and the reference light from light source interfere at the surface of the detector. When the translating stage moves towards the detector, the optical paths in the PC prism will be changed, and then the Doppler frequency shift will be generated. Though several different samples have been tested repeatedly, the results we get are extraordinarily similar. So we can be sure that the inverse Doppler effect really exists in the NIM at optical frequencies. To our best knowledge, this is the only experimental verification of the inverse Doppler effect in the NIM at optical frequencies at home and aboard.

  19. Dynamic tissue phantoms and their use in assessment of a noninvasive optical plethysmography imaging device

    Science.gov (United States)

    Thatcher, Jeffrey E.; Plant, Kevin D.; King, Darlene R.; Block, Kenneth L.; Fan, Wensheng; DiMaio, J. Michael

    2014-05-01

    Non-contact photoplethysmography (PPG) has been studied as a method to provide low-cost and non-invasive medical imaging for a variety of near-surface pathologies and two dimensional blood oxygenation measurements. Dynamic tissue phantoms were developed to evaluate this technology in a laboratory setting. The purpose of these phantoms was to generate a tissue model with tunable parameters including: blood vessel volume change; pulse wave frequency; and optical scattering and absorption parameters. A non-contact PPG imaging system was evaluated on this model and compared against laser Doppler imaging (LDI) and a traditional pulse oximeter. Results indicate non-contact PPG accurately identifies pulse frequency and appears to identify signals from optically dense phantoms with significantly higher detection thresholds than LDI.

  20. Arm locking with Doppler estimation errors

    Energy Technology Data Exchange (ETDEWEB)

    Yu Yinan; Wand, Vinzenz; Mitryk, Shawn; Mueller, Guido, E-mail: yinan@phys.ufl.ed [Department of Physics, University of Florida, Gainesville, FL 32611 (United States)

    2010-05-01

    At the University of Florida we developed the University of Florida LISA Interferometer Simulator (UFLIS) in order to study LISA interferometry with hardware in the loop at a system level. One of the proposed laser frequency stabilization techniques in LISA is arm locking. Arm locking uses an adequately filtered linear combination of the LISA arm signals as a frequency reference. We will report about experiments in which we demonstrated arm locking using UFLIS. During these experiments we also discovered a problem associated with the Doppler shift of the return beam. The initial arm locking publications assumed that this Doppler shift can perfectly be subtracted inside the phasemeter or adds an insignificant offset to the sensor signal. However, the remaining Doppler knowledge error will cause a constant change in the laser frequency if unaccounted for. Several ways to circumvent this problem have been identified. We performed detailed simulations and started preliminary experiments to verify the performance of the proposed new controller designs.

  1. Inline Ultrasonic Rheometry by Pulsed Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Pfund, David M.; Greenwood, Margaret S.; Bamberger, Judith A.; Pappas, Richard A.

    2006-12-22

    This will be a discussion of the non-invasive determination of the viscosity of a non-Newtonian fluid in laminar pipe flow over the range of shear rates present in the pipe. The procedure used requires knowledge of the flow profile in and the pressure drop along a long straight run of pipe. The profile is determined by using a pulsed ultrasonic Doppler velocimeter. This approach is ideal for making non-invasive, real-time measurements for monitoring and control. Rheograms of a shear thinning, thixotropic gel will be presented. The operating parameters and limitations of the Doppler-based instrument will be discussed. The most significant limitation is velocity gradient broadening of the Doppler spectra near the walls of the pipe. This limitation can be significant for strongly shear thinning fluids (depending also on the ratio of beam to pipe diameter and the transducer's insertion angle).

  2. Molecules cooled below the Doppler limit

    Science.gov (United States)

    Truppe, S.; Williams, H. J.; Hambach, M.; Caldwell, L.; Fitch, N. J.; Hinds, E. A.; Sauer, B. E.; Tarbutt, M. R.

    2017-12-01

    Magneto-optical trapping and sub-Doppler cooling have been essential to most experiments with quantum degenerate gases, optical lattices, atomic fountains and many other applications. A broad set of new applications await ultracold molecules, and the extension of laser cooling to molecules has begun. A magneto-optical trap (MOT) has been demonstrated for a single molecular species, SrF, but the sub-Doppler temperatures required for many applications have not yet been reached. Here we demonstrate a MOT of a second species, CaF, and we show how to cool these molecules to 50 μK, well below the Doppler limit, using a three-dimensional optical molasses. These ultracold molecules could be loaded into optical tweezers to trap arbitrary arrays for quantum simulation, launched into a molecular fountain for testing fundamental physics, and used to study collisions and chemistry between atoms and molecules at ultracold temperatures.

  3. Wide Angle Michelson Doppler Imaging Interferometer (WAMDII)

    Science.gov (United States)

    Roberts, B.

    1986-01-01

    The wide angle Michelson Doppler imaging interferometer (WAMDII) is a specialized type of optical Michelson interferometer working at sufficiently long path difference to measure Doppler shifts and to infer Doppler line widths of naturally occurring upper atmospheric Gaussian line emissions. The instrument is intended to measure vertical profiles of atmospheric winds and temperatures within the altitude range of 85 km to 300 km. The WAMDII consists of a Michelson interferometer followed by a camera lens and an 85 x 106 charge coupled device photodiode array. Narrow band filters in a filter wheel are used to isolate individual line emissions and the lens forms an image of the emitting region on the charge coupled device array.

  4. Diabetic Nephropathy : Evaluation with Doppler Ultrasonography

    International Nuclear Information System (INIS)

    Sim, Jung Suk; Kim, Seung Hyup; Kang, Heung Sik; Park, Jae Hyung; Han, Man Chung

    1996-01-01

    To compare Doppler ultrasonography with laboratory tests in evaluation of diabetic nephropathy. Fifty-five patients (mean age = 60, M : F = 26 : 29) with diabetes mellitus underwent renal Doppler ultrasonography. Resistive indices were compared with degree of proteinuria, serum creatinine level, and creatinine clearance rate. Eighteen patients who showed no proteinuria or microscopic proteinuria had a mean resistive index (RI) of 0.72 (SD, 0.05), 16 patients with macroscopic proteinuria without nephrotic syndrome had a mean RI of 0.82 (SD, 0.13), and 21 patients with nephrotic syndrome had a mean RI of 0.90 (SD, 0.12). Renal RI correlated highly with serum creatinine level (r = 0.62) and creatinine clearance rate (r = -0.43). Renal Doppler ultrasonography provides a useful indication of renal function in diabetic nephropathy but cannot offer an advantage over conventional laboratory test

  5. THD Doppler procedure for hemorrhoids: the surgical technique.

    Science.gov (United States)

    Ratto, C

    2014-03-01

    Transanal hemorrhoidal dearterialization (THD) is an effective treatment for hemorrhoidal disease. The ligation of hemorrhoidal arteries (called "dearterialization") can provide a significant reduction of the arterial overflow to the hemorrhoidal piles. Plication of the redundant rectal mucosa/submucosa (called "mucopexy") can provide a repositioning of prolapsing tissue to the anatomical site. In this paper, the surgical technique and perioperative patient management are illustrated. Following adequate clinical assessment, patients undergo THD under general or spinal anesthesia, in either the lithotomy or the prone position. In all patients, distal Doppler-guided dearterialization is performed, providing the selective ligation of hemorrhoidal arteries identified by Doppler. In patients with hemorrhoidal/muco-hemorrhoidal prolapse, the mucopexy is performed with a continuous suture including the redundant and prolapsing mucosa and submucosa. The description of the surgical procedure is complemented by an accompanying video (see supplementary material). In long-term follow-up, there is resolution of symptoms in the vast majority of patients. The most common complication is transient tenesmus, which sometimes can result in rectal discomfort or pain. Rectal bleeding occurs in a very limited number of patients. Neither fecal incontinence nor chronic pain should occur. Anorectal physiology parameters should be unaltered, and anal sphincters should not be injured by following this procedure. When accurately performed and for the correct indications, THD is a safe procedure and one of the most effective treatments for hemorrhoidal disease.

  6. A Generalized Wave Diagram for Moving Sources

    Science.gov (United States)

    Alt, Robert; Wiley, Sam

    2004-12-01

    Many introductory physics texts1-5 accompany the discussion of the Doppler effect and the formation of shock waves with diagrams illustrating the effect of a source moving through an elastic medium. Typically these diagrams consist of a series of equally spaced dots, representing the location of the source at different times. These are surrounded by a series of successively smaller circles representing wave fronts (see Fig. 1). While such a diagram provides a clear illustration of the shock wave produced by a source moving at a speed greater than the wave speed, and also the resultant pattern when the source speed is less than the wave speed (the Doppler effect), the texts do not often show the details of the construction. As a result, the key connection between the relative distance traveled by the source and the distance traveled by the wave is not explicitly made. In this paper we describe an approach emphasizing this connection that we have found to be a useful classroom supplement to the usual text presentation. As shown in Fig. 2 and Fig. 3, the Doppler effect and the shock wave can be illustrated by diagrams generated by the construction that follows.

  7. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  8. Proposed protocols for peripheral and renal Doppler

    International Nuclear Information System (INIS)

    Fonseca Portuguez, Adriana

    2009-01-01

    A literature review was performed in order to prepare a summary of the important concepts of Doppler and applications in peripheral vascular evaluation and renal. The normal characteristics are summarized and explained in each vascular system and diagnostic criteria of the disorders frequently encountered in practice. Requested more studies have been identified and proposed protocols and report sheets have been developed to standardize the methodology of realization of several Doppler studies. The variability between operators has been treated to reduce as much as possible and follow-up studies have provided in patients who need. (author) [es

  9. Arterial wave reflection and subclinical left ventricular systolic dysfunction.

    Science.gov (United States)

    Russo, Cesare; Jin, Zhezhen; Takei, Yasuyoshi; Hasegawa, Takuya; Koshaka, Shun; Palmieri, Vittorio; Elkind, Mitchell Sv; Homma, Shunichi; Sacco, Ralph L; Di Tullio, Marco R

    2011-03-01

    Increased arterial wave reflection is a predictor of cardiovascular events and has been hypothesized to be a cofactor in the pathophysiology of heart failure. Whether increased wave reflection is inversely associated with left-ventricular (LV) systolic function in individuals without heart failure is not clear. Arterial wave reflection and LV systolic function were assessed in 301 participants from the Cardiovascular Abnormalities and Brain Lesions (CABL) study using two-dimensional echocardiography and applanation tonometry of the radial artery to derive central arterial waveform by a validated transfer function. Aortic augmentation index (AIx) and wasted energy index (WEi) were used as indices of wave reflection. LV systolic function was measured by LV ejection fraction (LVEF) and tissue Doppler imaging (TDI). Mitral annulus peak systolic velocity (Sm), peak longitudinal strain and strain rate were measured. Participants with history of coronary artery disease, atrial fibrillation, LVEF less than 50% or wall motion abnormalities were excluded. Mean age of the study population was 68.3 ± 10.2 years (64.1% women, 65% hypertensive). LV systolic function by TDI was lower with increasing wave reflection, whereas LVEF was not. In multivariate analysis, TDI parameters of LV longitudinal systolic function were significantly and inversely correlated to AIx and WEi (P values from 0.05 to 0.002). In a community cohort without heart failure and with normal LVEF, an increased arterial wave reflection was associated with subclinical reduction in LV systolic function assessed by novel TDI techniques. Further studies are needed to investigate the prognostic implications of this relationship.

  10. Distribution of Doppler Redshifts of Associated Absorbers of SDSS ...

    Indian Academy of Sciences (India)

    The authors searched all ... quasar, where the contribution of the Doppler motion is relatively small. ..... might contribute to the Doppler redshift distribution. 5. ... out accounting for the contamination of intervening absorption systems, which can.

  11. GRIP DOPPLER AEROSOL WIND LIDAR (DAWN) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The GRIP Doppler Aerosol WiNd Lidar (DAWN) Dataset was collected by the Doppler Aerosol WiNd (DAWN), a pulsed lidar, which operated aboard a NASA DC-8 aircraft...

  12. Operational Bright-Band Snow Level Detection Using Doppler Radar

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — A method to detect the bright-band snow level from radar reflectivity and Doppler vertical velocity data collection with an atmospheric profiling Doppler radar. The...

  13. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The EDOP provides vertically profiled reflectivity and Doppler velocity at aircraft nadir along the flight track. The ER-2 Doppler radar (EDOP) is an X-band (9.6...

  14. ISAR imaging using the instantaneous range instantaneous Doppler method

    CSIR Research Space (South Africa)

    Wazna, TM

    2015-10-01

    Full Text Available In Inverse Synthetic Aperture Radar (ISAR) imaging, the Range Instantaneous Doppler (RID) method is used to compensate for the nonuniform rotational motion of the target that degrades the Doppler resolution of the ISAR image. The Instantaneous Range...

  15. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  16. Chaos weak signal detecting algorithm and its application in the ultrasonic Doppler bloodstream speed measuring

    International Nuclear Information System (INIS)

    Chen, H Y; Lv, J T; Zhang, S Q; Zhang, L G; Li, J

    2005-01-01

    At the present time, the ultrasonic Doppler measuring means has been extensively used in the human body's bloodstream speed measuring. The ultrasonic Doppler measuring means can achieve the measuring of liquid flux by detecting Doppler frequency shift of ultrasonic in the process of liquid spread. However, the detected sound wave is a weak signal that is flooded in the strong noise signal. The traditional measuring method depends on signal-to-noise ratio. Under the very low signal-to-noise ratio or the strong noise signal background, the signal frequency is not measured. This article studied on chaotic movement of Duffing oscillator and intermittent chaotic characteristic on chaotic oscillator of Duffing equation. In the light of the range of the bloodstream speed of human body and the principle of Doppler shift, the paper determines the frequency shift range. An oscillator array including many oscillators is designed according to it. The reflected ultrasonic frequency information can be ascertained accurately by the intermittent chaos quality of the oscillator. The signal-to-noise ratio of -26.5 dB is obtained by the result of the experiment. Compared with the tradition the frequency method compare, the dependence to signal-to-noise ratio is lowered consumedly. The measuring precision of the bloodstream speed is heightened

  17. [Doppler ultrasound evaluation of aortic insufficiency using half-pressure time. Absence of arterial rigidity influence].

    Science.gov (United States)

    Kalotka-Bratek, H; Drobinski, G; Klimczak, K; Busquet, P; Fraysse, J B; Bejean-Lebuisson, A; Grosgogeat, Y

    1989-02-01

    In 20 patients with pure aortic regurgitation we studied the relationship between the severity of regurgitation, as assessed haemodynamically by the percentage of leakage (%L), and the half-pressure (T 1/2 P) and half-velocity (T 1/2 V) times, as obtained from doppler aortic blood velocity curves, taking into account the rigidity of the systemic vascular circuit characterized by the pressure wave propagation velocity (PWPV). The systemic arterial circuit was supple in 14 patients (PWPV less than 7.5 m/sec) and rigid in 6 patients (PWPV greater than 7.5 m/sec). The regression slopes between %L and T 1/2 P and between %L and T 1/2 V were calculated with their confidence limits in the 14 patients with supple arteries. The 6 patients with rigid arteries fitted into this nomogram, thus demonstrating that systemic arterial rigidity makes no difference in the relationship between %L and doppler indices. The half-velocity and half-pressure times measured by doppler ultrasound were acquired from a velocity signal directly determined by the aortic regurgitation, without any detectable effect of vascular circuit rigidity. Being equivalent by nature to the signal decrease time constant, they are independent of the absolute protodiastolic value of diastolic pressure gradient or blood flow velocity. For this reason these two doppler parameters are reliable to evaluate the severity of aortic regurgitation.

  18. Transcranial Doppler velocimetry in aneurysmal subarachnoid haemorrhage

    DEFF Research Database (Denmark)

    Staalsø, J M; Edsen, T; Romner, B

    2013-01-01

    -coded transcranial Doppler (TCCD), with the secondary aim of describing prediction of angiographic vasospasm and mortality. METHODS: /st>Sixty patients and 70 healthy controls were each examined in duplicate by alternating operators. A total of 939 measurements divided on 201 examination sets were conducted by four...

  19. Doppler Sonographic Evaluation of Venogenic Extremity Swellings ...

    African Journals Online (AJOL)

    2017-09-14

    Sep 14, 2017 ... potentially lead to many complications including life-threatening pulmonary arterial thrombosis. Screening and confirmation ... and exclusion of acute lower extremity DVT. Duplex ultrasound is considered as the ... this study evaluates the role of Doppler sonography in the clinical management of suspected.

  20. Complex regression Doppler optical coherence tomography

    Science.gov (United States)

    Elahi, Sahar; Gu, Shi; Thrane, Lars; Rollins, Andrew M.; Jenkins, Michael W.

    2018-04-01

    We introduce a new method to measure Doppler shifts more accurately and extend the dynamic range of Doppler optical coherence tomography (OCT). The two-point estimate of the conventional Doppler method is replaced with a regression that is applied to high-density B-scans in polar coordinates. We built a high-speed OCT system using a 1.68-MHz Fourier domain mode locked laser to acquire high-density B-scans (16,000 A-lines) at high enough frame rates (˜100 fps) to accurately capture the dynamics of the beating embryonic heart. Flow phantom experiments confirm that the complex regression lowers the minimum detectable velocity from 12.25 mm / s to 374 μm / s, whereas the maximum velocity of 400 mm / s is measured without phase wrapping. Complex regression Doppler OCT also demonstrates higher accuracy and precision compared with the conventional method, particularly when signal-to-noise ratio is low. The extended dynamic range allows monitoring of blood flow over several stages of development in embryos without adjusting the imaging parameters. In addition, applying complex averaging recovers hidden features in structural images.

  1. Doppler Shift Compensation Schemes in VANETs

    Directory of Open Access Journals (Sweden)

    F. Nyongesa

    2015-01-01

    Full Text Available Over the last decade vehicle-to-vehicle (V2V communication has received a lot of attention as it is a crucial issue in intravehicle communication as well as in Intelligent Transportation System (ITS. In ITS the focus is placed on integration of communication between mobile and fixed infrastructure to execute road safety as well as nonsafety information dissemination. The safety application such as emergence alerts lays emphasis on low-latency packet delivery rate (PDR, whereas multimedia and infotainment call for high data rates at low bit error rate (BER. The nonsafety information includes multimedia streaming for traffic information and infotainment applications such as playing audio content, utilizing navigation for driving, and accessing Internet. A lot of vehicular ad hoc network (VANET research has focused on specific areas including channel multiplexing, antenna diversity, and Doppler shift compensation schemes in an attempt to optimize BER performance. Despite this effort few surveys have been conducted to highlight the state-of-the-art collection on Doppler shift compensation schemes. Driven by this cause we survey some of the recent research activities in Doppler shift compensation schemes and highlight challenges and solutions as a stock-taking exercise. Moreover, we present open issues to be further investigated in order to address the challenges of Doppler shift in VANETs.

  2. Fifty Years of HF Doppler Observations

    Directory of Open Access Journals (Sweden)

    T Ogawa

    2009-04-01

    Full Text Available High frequency Doppler observations of the ionosphere began in August of 1957 in Kyoto. The number of the observation points worldwide were about 40 in 1980 and are about 20 at present. By this method the movement of the ionosphere reflection height and electron density below the height can be observed. Such variations are occurred by a wide variety of sources.

  3. Ultrasonic Doppler color in glaucoma: Concordance study

    International Nuclear Information System (INIS)

    Uriza, Felipe; Useche, Nicolas

    2005-01-01

    Our study demonstrates that US color Doppler is a non invasive, reliable and reproducible method for the evaluation of the orbitary flow in normal and glaucomatous patients. However is suggested that every group evaluates the inter and intraobserver variability because of the lack of universal reference velocity measurements

  4. Aerosol distribution measurements by laser - Doppler - spectroscopy

    International Nuclear Information System (INIS)

    Baldassari, J.

    1977-01-01

    Laser-Doppler-Spectroscopy is used to study particle size distribution, especially sodium aerosols, in the presence of uncondensable gases. Theoretical basis are given, and an experimental technique is described. First theoretical results show reasonably good agreement with experimental data available; this method seems to be a promising one. (author)

  5. Laser Doppler thermometry in flat flames

    NARCIS (Netherlands)

    Maaren, van A.; Goey, de L.P.H.

    1994-01-01

    Laser Doppler Velocimetry measurements are performed in flat flames, stabilized on a newly developed flat-flame burner. It is shown that the velocity component perpendicular to the main flow direction, induced by expansion in the reaction zone and buoyancy in the burnt gas, is significant. A method

  6. Measurement of ciliary beat frequency using Doppler optical coherence tomography.

    Science.gov (United States)

    Lemieux, Bryan T; Chen, Jason J; Jing, Joseph; Chen, Zhongping; Wong, Brian J F

    2015-11-01

    Measuring ciliary beat frequency (CBF) is a technical challenge and difficult to perform in vivo. Doppler optical coherence tomography (D-OCT) is a mesoscopic noncontact imaging modality that provides high-resolution tomographic images and detects micromotion simultaneously in living tissues. In this work we used D-OCT to measure CBF in ex vivo tissue as the first step toward translating this technology to clinical use. Fresh ex vivo samples of rabbit tracheal mucosa were imaged using both D-OCT and phase-contrast microscopy (n = 5). The D-OCT system was designed and built to specification in our lab (1310-nm swept source vertical-cavity surface-emitting laser [VCSEL], 6-μm axial resolution). The samples were placed in culture and incubated at 37°C. A fast Fourier transform was performed on the D-OCT signal recorded on the surface of the samples to gauge CBF. High-speed digital video of the epithelium recorded via phase-contrast microscopy was analyzed to confirm the CBF measurements. The D-OCT system detected Doppler signal at the epithelial layer of ex vivo rabbit tracheal samples suggestive of ciliary motion. CBF was measured at 9.36 ± 1.22 Hz using D-OCT and 9.08 ± 0.48 Hz using phase-contrast microscopy. No significant differences were found between the 2 methods (p > 0.05). D-OCT allows for the quantitative measurement of CBF without the need to resolve individual cilia. Furthermore, D-OCT technology can be incorporated into endoscopic platforms that allow clinicians to readily measure CBF in the office and provide a direct measurement of mucosal health. © 2015 ARS-AAOA, LLC.

  7. TCSP ER-2 DOPPLER RADAR (EDOP) V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The TCSP ER-2 DOPPLER RADAR (EDOP) dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of the ER-2...

  8. CAMEX-4 ER-2 DOPPLER RADAR V1

    Data.gov (United States)

    National Aeronautics and Space Administration — The CAMEX-4 ER-2 Doppler Radar dataset was collected by the ER-2 Doppler radar (EDOP), which is an X-band (9.6 GHz) Doppler radar mounted in the nose of ER-2. The...

  9. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  10. Evaluation of healthy muscle tissue by strain and shear wave elastography – Dependency on depth and ROI position in relation to underlying bone

    DEFF Research Database (Denmark)

    Ewertsen, Caroline; Carlsen, Jonathan Frederik; Christiansen, Iben Riishede

    2016-01-01

    and methods: Ten healthy volunteers (five males and five females) had their biceps brachii, gastrocnemius, and quadriceps muscle examined with strain- and shear wave elastography at three different depths and in regions located above bone and beside bone. Strain ratios were averaged from cine-loops of 10 s...

  11. Model experiments on imaging subsurface fracture permeability by pulsed Doppler borehole televiewer; Pulse doppler borehole televiewer ni yoru kiretsu tosuisei hyoka ni kansuru model jikken

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Y; Niitsuma, H [Tohoku University, Sendai (Japan). Faculty of Engineering

    1996-05-01

    This paper reports model experiments to evaluate flow rates of fluids passing through a fracture by using a Doppler borehole televiewer (DBHTV). A supersonic transducer disposed on a well axis transmits transmission pulses, and a transducer receives scattered waves generated by particulates in water and waves reflected on a well wall. This signal is applied with time gating to extract only the scattered waves from particulates in the vicinity of the well wall. Deriving spectra in the recorded Doppler signal obtains flow velocity components in the direction of the well radius. A model was made with a polyvinylchloride pipe with a diameter of 14.6 cm to simulate a well, to which an aluminum pipe with an inner diameter of 2 mm is connected to be used as a simulated fracture, and mud water is circulated in the pipe. The result of deriving a passed flow volume in this model by integrating flow rate distribution derived by using the above method to a predetermined range in the vicinity of the fracture showed a good proportional relationship with actual flow rate in the simulated fracture. 1 ref., 7 figs.

  12. Doppler speedometer for micro-organisms

    International Nuclear Information System (INIS)

    Penkov, F.; Tuleushev, A.; Lisitsyn, V.; Kim, S.; Tuleushev, Yu.

    1996-01-01

    Objective of Investigations: Development and creation of the Doppler speedometer for micro-organisms which allows to evaluate, in a real temporal scale, variations in the state of water suspension of micro-organisms under the effect of chemical, physical and other external actions. Statement of the Problem The main problem is absence of reliable, accessible for users and simple, in view of application, Doppler speedometers for micro-organisms. Nevertheless, correlation Doppler spectrometry in the regime of heterodyning the supporting and cell-scattered laser radiation is welt known. The main idea is that the correlation function of photo-current pulses bears an information on the averages over the assembly of cell velocities. For solving the biological problems, construction of auto-correlation function in the real-time regime with the delay time values comprising, function in the real-time regime with the delay time values comprising, nearly, 100 me (10 khz) or higher is needed. Computers of high class manage this problem using but the program software. Due to this, one can simplify applications of the proposed techniques provided he creates the Doppler speedometer for micro-organism on a base of the P entium . Expected Result Manufactured operable mock-up of the Doppler speedometer for micro-organisms in a form of the auxiliary computer block which allows to receive an information, in the real time scale, on the results of external effects of various nature on the cell assembly in transparent medium with a small volume of the studied cell suspension

  13. Minimally destructive Doppler measurement of a quantized, superfluid flow

    Science.gov (United States)

    Anderson, Neil; Kumar, Avinash; Eckel, Stephen; Stringari, Sandro; Campbell, Gretchen

    2016-05-01

    Ring shaped Bose-Einstein condensates are of interest because they support the existence of quantized, persistent currents. These currents arise because in a ring trap, the wavefunction of the condensate must be single valued, and thus the azimuthal velocity is quantized. Previously, these persistent current states have only been measured in a destructive fashion via either interference with a phase reference or using the size of a central vortex-like structure that appears in time of flight. Here, we demonstrate a minimally destructive, in-situ measurement of the winding number of a ring shaped BEC. We excite a standing wave of phonon modes in the ring BEC using a perturbation. If the condensate is in a nonzero circulation state, then the frequency of these phonon modes are Doppler shifted, causing the standing wave to precess about the ring. From the direction and velocity of this precession, we can infer the winding number of the flow. For certain parameters, this technique can detect individual winding numbers with approximately 90% fidelity.

  14. The Pathophysiology of Decompression Sickness and the Effects of Doppler Detectable Bubbles.

    Science.gov (United States)

    1980-12-18

    workers (Harvey, 1951a and 1951b) and Blinks, Twitty and Whiteker (1951) show that muscular activity was a 23 ~I. predisposing factor to the formation of...Hills, 1966), the mechanism of action is somewhat specific (neural distension ); but for those theories utilizing circulation and/or intravascular...highly perfused non- muscular tissue, such as kidney, forms a gas phase following decompression, Doppler perivascular cuff probes were surgically placed on

  15. Comparison of NIRS, laser Doppler flowmetry, photoplethysmography, and pulse oximetry during vascular occlusion challenges

    OpenAIRE

    Abay, T. Y.; Kyriacou, P. A.

    2016-01-01

    © 2016 Institute of Physics and Engineering in Medicine. Monitoring changes in blood volume, blood flow, and oxygenation in tissues is of vital importance in fields such as reconstructive surgery and trauma medicine. Near infrared spectroscopy (NIRS), laser Doppler (LDF) flowmetry, photoplethysmography (PPG), and pulse oximetry (PO) contribute to such fields due to their safe and noninvasive nature. However, the techniques have been rarely investigated simultaneously or altogether. The aim of...

  16. Design And Analysis Of Doppler Radar-Based Vehicle Speed Detection

    Directory of Open Access Journals (Sweden)

    Su Myat Paing

    2015-08-01

    Full Text Available The most unwanted thing to happen to a road user is road accident. Most of the fatal accidents occur due to over speeding. Faster vehicles are more prone to accident than the slower one. Among the various methods for detecting speed of the vehicle object detection systems based on Radar have been replaced for about a century for various purposes like detection of aircrafts spacecraft ships navigation reading weather formations and terrain mapping. The essential feature in adaptive vehicle activated sign systems is the accurate measurement of a vehicles velocity. The velocities of the vehicles are acquired from a continuous wave Doppler radar. A very low amount of power is consumed in this system and only batteries can use to operate. The system works on the principle of Doppler Effect by detecting the Doppler shift in microwaves reflected from a moving object. Since the output of the sensor is sinusoidal wave with very small amplitude and needs to be amplified with the help of the amplifier before further processing. The purpose to calculate and display the speed on LCD is performed by the microcontroller.

  17. The medical Doppler in hand surgery: its scientific basis, applications, and the history of its namesake, Christian Johann Doppler.

    Science.gov (United States)

    Ghori, Ahmer K; Chung, Kevin C

    2007-12-01

    The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.

  18. Wave mixing spectroscopy

    International Nuclear Information System (INIS)

    Smith, R.W.

    1980-08-01

    Several new aspects of nonlinear or wave mixing spectroscopy were investigated utilizing the polarization properties of the nonlinear output field and the dependence of this field upon the occurrence of multiple resonances in the nonlinear susceptibility. First, it is shown theoretically that polarization-sensitive detection may be used to either eliminate or controllably reduce the nonresonant background in coherent anti-Stokes Raman spectroscopy, allowing weaker Raman resonances to be studied. The features of multi-resonant four-wave mixing are examined in the case of an inhomogeneously broadened medium. It is found that the linewidth of the nonlinear output narrows considerably (approaching the homogeneous width) when the quantum mechanical expressions for the doubly- and triply-resonant susceptibilities are averaged over a Doppler or strain broadened profile. Experimental studies of nonlinear processes in Pr +3 :LaF 3 verify this linewidth narrowing, but indicate that this strain broadened system cannot be treated with a single broadening parameter as in the case of Doppler broadening in a gas. Several susceptibilities are measured from which are deduced dipole matrix elements and Raman polarizabilities related to the 3 H 4 , 3 H 6 , and 3 P 0 levels of the praseodymium ions

  19. Wave Breaking, Bubble Production and Acoustic Characteristics of the Surf Zone, SIO Component

    National Research Council Canada - National Science Library

    Deane, Grant

    2001-01-01

    .... The purpose of these measurements was to: (1) statistically characterize the surf zone acoustic channel Doppler and time spreads, and acoustic drop-outs, in terms of the incident wave field and (2...

  20. Stress wave focusing transducers

    Energy Technology Data Exchange (ETDEWEB)

    Visuri, S.R., LLNL

    1998-05-15

    Conversion of laser radiation to mechanical energy is the fundamental process behind many medical laser procedures, particularly those involving tissue destruction and removal. Stress waves can be generated with laser radiation in several ways: creation of a plasma and subsequent launch of a shock wave, thermoelastic expansion of the target tissue, vapor bubble collapse, and ablation recoil. Thermoelastic generation of stress waves generally requires short laser pulse durations and high energy density. Thermoelastic stress waves can be formed when the laser pulse duration is shorter than the acoustic transit time of the material: {tau}{sub c} = d/c{sub s} where d = absorption depth or spot diameter, whichever is smaller, and c{sub s} = sound speed in the material. The stress wave due to thermoelastic expansion travels at the sound speed (approximately 1500 m/s in tissue) and leaves the site of irradiation well before subsequent thermal events can be initiated. These stress waves, often evolving into shock waves, can be used to disrupt tissue. Shock waves are used in ophthalmology to perform intraocular microsurgery and photodisruptive procedures as well as in lithotripsy to fragment stones. We have explored a variety of transducers that can efficiently convert optical to mechanical energy. One such class of transducers allows a shock wave to be focused within a material such that the stress magnitude can be greatly increased compared to conventional geometries. Some transducer tips could be made to operate regardless of the absorption properties of the ambient media. The size and nature of the devices enable easy delivery, potentially minimally-invasive procedures, and precise tissue- targeting while limiting thermal loading. The transducer tips may have applications in lithotripsy, ophthalmology, drug delivery, and cardiology.

  1. Application of scanning laser Doppler vibrometry for delamination detection in composite structures

    Science.gov (United States)

    Kudela, Pawel; Wandowski, Tomasz; Malinowski, Pawel; Ostachowicz, Wieslaw

    2017-12-01

    In this paper application of scanning laser Doppler vibrometry for delamination detection in composite structures was presented. Delamination detection was based on a guided wave propagation method. In this papers results from numerical and experimental research were presented. In the case of numerical research, the Spectral Element Method (SEM) was utilized, in which a mesh was composed of 3D spectral elements. SEM model included also a piezoelectric transducer. In the experimental research guided waves were excited using the piezoelectric transducer whereas the sensing process was conducted using scanning laser Doppler vibrometer (SLDV). Analysis of guided wave propagation and its interaction with delamination was based on a full wavefield approach. Attention was focused on interactions of guided waves with delamination manifested by A0 mode reflection, A0 mode entrapment, and S0/A0 mode conversion. Delamination was simulated by a teflon insert located between plies of composite material. Results of interaction with symmetrically and nonsymmetrical placed delamination (in respect to the composite sample thickness) were presented. Moreover, the authors investigated different size of delaminations. Damage detection was based on a new signal processing algorithm proposed by the authors. In this approach the weighted RMS was utilized selectively. It means that the summation in RMS formula was performed only for a specially selected time instances. Results for simple composite panels, panel with honeycomb core, and real stiffened composite panel from the aircraft were presented.

  2. A fiber optic Doppler sensor and its application in debonding detection for composite structures.

    Science.gov (United States)

    Li, Fucai; Murayama, Hideaki; Kageyama, Kazuro; Meng, Guang; Ohsawa, Isamu; Shirai, Takehiro

    2010-01-01

    Debonding is one of the most important damage forms in fiber-reinforced composite structures. This work was devoted to the debonding damage detection of lap splice joints in carbon fiber reinforced plastic (CFRP) structures, which is based on guided ultrasonic wave signals captured by using fiber optic Doppler (FOD) sensor with spiral shape. Interferometers based on two types of laser sources, namely the He-Ne laser and the infrared semiconductor laser, are proposed and compared in this study for the purpose of measuring Doppler frequency shift of the FOD sensor. Locations of the FOD sensors are optimized based on mechanical characteristics of lap splice joint. The FOD sensors are subsequently used to detect the guided ultrasonic waves propagating in the CFRP structures. By taking advantage of signal processing approaches, features of the guided wave signals can be revealed. The results demonstrate that debonding in the lap splice joint results in arrival time delay of the first package in the guided wave signals, which can be the characteristic for debonding damage inspection and damage extent estimation.

  3. Minimally destructive, Doppler measurement of a quantized flow in a ring-shaped Bose-Einstein condensate

    Science.gov (United States)

    Kumar, A.; Anderson, N.; Phillips, W. D.; Eckel, S.; Campbell, G. K.; Stringari, S.

    2016-02-01

    The Doppler effect, the shift in the frequency of sound due to motion, is present in both classical gases and quantum superfluids. Here, we perform an in situ, minimally destructive measurement, of the persistent current in a ring-shaped, superfluid Bose-Einstein condensate using the Doppler effect. Phonon modes generated in this condensate have their frequencies Doppler shifted by a persistent current. This frequency shift will cause a standing-wave phonon mode to be ‘dragged’ along with the persistent current. By measuring this precession, one can extract the background flow velocity. This technique will find utility in experiments where the winding number is important, such as in emerging ‘atomtronic’ devices.

  4. Explaining Polarization Reversals in STEREO Wave Data

    Science.gov (United States)

    Breneman, A.; Cattell, C.; Wygant, J.; Kersten, K.; Wilson, L, B., III; Dai, L.; Colpitts, C.; Kellogg, P. J.; Goetz, K.; Paradise, A.

    2012-01-01

    Recently Breneman et al. reported observations of large amplitude lightning and transmitter whistler mode waves from two STEREO passes through the inner radiation belt (Lpaper. We show, with a combination of observations and simulated wave superposition, that these polarization reversals are due to the beating of an incident electromagnetic whistler mode wave at 21.4 kHz and linearly polarized, symmetric lower hybrid sidebands Doppler-shifted from the incident wave by +/-200 Hz. The existence of the lower hybrid waves is consistent with the parametric decay mechanism of Lee and Kuo whereby an incident whistler mode wave decays into symmetric, short wavelength lower hybrid waves and a purely growing (zero-frequency) mode. Like the lower hybrid waves, the purely growing mode is Doppler-shifted by 200 Hz as observed on STEREO. This decay mechanism in the upper ionosphere has been previously reported at equatorial latitudes and is thought to have a direct connection with explosive spread F enhancements. As such it may represent another dissipation mechanism of VLF wave energy in the ionosphere and may help to explain a deficit of observed lightning and transmitter energy in the inner radiation belts as reported by Starks et al.

  5. Doppler echocardiographic predictors of mortality in female rats after myocardial infarction.

    Science.gov (United States)

    Santos, Alexandra Alberta; Helber, Izzo; Flumignan, Ronald L G; Antonio, Ednei L; Carvalho, Antonio C; Paola, Angelo A; Tucci, Paulo J; Moises, Valdir A

    2009-03-01

    Doppler echocardiogram is useful for the evaluation of anatomical and functional changes in late myocardial infarction (MI) in rats. However, no studies have evaluated the prognostic value of echocardiographic parameters 1 week after MI. Doppler echocardiogram was performed in 84 female Wistar rats 1 week after MI to determine infarction size, left chambers dimensions, fractional area change (FAC) of the left ventricle (LV), mitral inflow and tissue Doppler, myocardial performance index (MPI), and signs of pulmonary hypertension. The 365-day follow-up showed 53.6% mortality rate. Nonsurvivors showed larger (P or=0.60 (RR 3.49, 95% CI, 1.80-6.76), LV systolic area >or=0.26 cm(2) (RR 4.38, 95% CI, 1.88-10.21), E/E' ratio >or=20.3 (RR 2.12, 95% CI, 1.15-4.34), and E/A ratio associated with FAC (RR 2.99, 95% CI, 1.44-6.18). Some diastolic and systolic Doppler echocardiographic parameters in rats may be able to predict late mortality risk after MI.

  6. State-of-the-art HR-US imaging findings of the most frequent musculoskeletal soft-tissue tumors

    International Nuclear Information System (INIS)

    Widmann, Gerlig; Riedl, Andreas; Schoepf, Daniel; Glodny, Bernhard; Peer, Siegfried; Gruber, Hannes

    2009-01-01

    High resolution ultrasound (HR-US) including color Doppler ultrasound (CD-US), power Doppler ultrasound (PD-US), and spectral wave analysis (SWA), is a broadly available, non-invasive and relatively low-cost modality without ionizing radiation. It is increasingly used for initial assessment of an ambiguous musculoskeletal soft-tissue lesion and for sonographically guided core biopsy. The aim of this review is to provide sonographic findings of the most frequent benign and malign soft-tissue lesions. By this essay, we can show that combined with clinical features, with information on tumor-localization and patient age, many musculoskeletal lesions may be successfully characterized by HR-US. In contrast, a mere morphologic assignment of some fibrous tumors and malignant lesions remains often impossible; however, certain CD-US signs such as anarchic vascular architecture or arteriovenous shunting may be very helpful indicators for malignancy. HR-US offers a simple, quick, and reliable first-line examination of musculoskeletal soft-tissue lesions and may have an important role in the diagnostic work-up followed by magnetic resonance or multimodality imaging and guided core biopsy. (orig.)

  7. Doppler and time-travel broadening in ICR plasma isotope separation

    International Nuclear Information System (INIS)

    Karchevskii, A.I.; Potanin, E.P.

    1994-01-01

    Isotopically-selective ion-cyclotron resonance (ICR) heating is one of the most promising plasma isotope separation methods. The separation degree of ICR separation in a plasma depends on the resonance heating selectivity. The selectivity is due to the isotopically-adjacent accelerated ions resonance curve overlapping and therefore, is determined by the width of the resonance curves. In the case of a collisionless plasma in an ideal homogeneous longitudinal magnetic field, the line broadening is mainly determined by Doppler and time-travel effects. These effects differ in nature, and one has some difficulties in distinguishing them when interpreting the resonance curves because both broadenings depend on ion axial velocities. We consider the simplest case: the extrenal heating alternating electric field does not depend on the axial coordinate (the wave number γ = 0). Hence, in this case the Doppler effect does not occur

  8. Comparative study of the performance of semiconductor laser based coherent Doppler lidars

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2012-01-01

    Coherent Doppler Lidars (CDLs), operating at an eye-safe 1.5-micron wavelength, have found promising applications in the optimization of wind-power production. To meet the wind-energy sector's impending demand for more cost-efficient industrial sensors, we have focused on the development of conti......Coherent Doppler Lidars (CDLs), operating at an eye-safe 1.5-micron wavelength, have found promising applications in the optimization of wind-power production. To meet the wind-energy sector's impending demand for more cost-efficient industrial sensors, we have focused on the development...... of continuous-wave CDL systems using compact, inexpensive semiconductor laser (SL) sources. In this work, we compare the performance of two candidate emitters for an allsemiconductor CDL system: (1) a monolithic master-oscillator-power-amplifier (MOPA) SL and (2) an external-cavity tapered diode laser (ECTDL)....

  9. Doppler Radar Vital Signs Detection Method Based on Higher Order Cyclostationary.

    Science.gov (United States)

    Yu, Zhibin; Zhao, Duo; Zhang, Zhiqiang

    2017-12-26

    Due to the non-contact nature, using Doppler radar sensors to detect vital signs such as heart and respiration rates of a human subject is getting more and more attention. However, the related detection-method research meets lots of challenges due to electromagnetic interferences, clutter and random motion interferences. In this paper, a novel third-order cyclic cummulant (TOCC) detection method, which is insensitive to Gaussian interference and non-cyclic signals, is proposed to investigate the heart and respiration rate based on continuous wave Doppler radars. The k -th order cyclostationary properties of the radar signal with hidden periodicities and random motions are analyzed. The third-order cyclostationary detection theory of the heart and respiration rate is studied. Experimental results show that the third-order cyclostationary approach has better estimation accuracy for detecting the vital signs from the received radar signal under low SNR, strong clutter noise and random motion interferences.

  10. Understanding the Doppler effect by analysing spectrograms of the sound of a passing vehicle

    Science.gov (United States)

    Lubyako, Dmitry; Martinez-Piedra, Gordon; Ushenin, Arthur; Denvir, Patrick; Dunlop, John; Hall, Alex; Le Roux, Gus; van Someren, Laurence; Weinberger, Harvey

    2017-11-01

    The purpose of this paper is to demonstrate how the Doppler effect can be analysed to deduce information about a moving source of sound waves. Specifically, we find the speed of a car and the distance of its closest approach to an observer using sound recordings from smartphones. A key focus of this paper is how this can be achieved in a classroom, both theoretically and experimentally, to deepen students’ understanding of the Doppler effect. Included are our own experimental data (48 sound recordings) to allow others to reproduce the analysis, if they cannot repeat the whole experiment themselves. In addition to its educational purpose, this paper examines the percentage errors in our results. This enabled us to determine sources of error, allowing those conducting similar future investigations to optimize their accuracy.

  11. Measurement of two-dimensional Doppler wind fields using a field widened Michelson interferometer.

    Science.gov (United States)

    Langille, Jeffery A; Ward, William E; Scott, Alan; Arsenault, Dennis L

    2013-03-10

    An implementation of the field widened Michelson concept has been applied to obtain high resolution two-dimensional (2D) images of low velocity (interferometer scanning mirror position is controlled to subangstrom precision with subnanometer repeatability using the multi-application low-voltage piezoelectric instrument control electronics developed by COM DEV Ltd.; it is the first implementation of this system as a phase stepping Michelson. In this paper the calibration and characterization of the Doppler imaging system is described and the planned implementation of this new technique for imaging 2D wind and irradiance fields using the earth's airglow is introduced. Observations of Doppler winds produced by a rotating wheel are reported and shown to be of sufficient precision for buoyancy wave observations in airglow in the mesopause region of the terrestrial atmosphere.

  12. A micro-Doppler sonar for acoustic surveillance in sensor networks

    Science.gov (United States)

    Zhang, Zhaonian

    Wireless sensor networks have been employed in a wide variety of applications, despite the limited energy and communication resources at each sensor node. Low power custom VLSI chips implementing passive acoustic sensing algorithms have been successfully integrated into an acoustic surveillance unit and demonstrated for detection and location of sound sources. In this dissertation, I explore active and passive acoustic sensing techniques, signal processing and classification algorithms for detection and classification in a multinodal sensor network environment. I will present the design and characterization of a continuous-wave micro-Doppler sonar to image objects with articulated moving components. As an example application for this system, we use it to image gaits of humans and four-legged animals. I will present the micro-Doppler gait signatures of a walking person, a dog and a horse. I will discuss the resolution and range of this micro-Doppler sonar and use experimental results to support the theoretical analyses. In order to reduce the data rate and make the system amenable to wireless sensor networks, I will present a second micro-Doppler sonar that uses bandpass sampling for data acquisition. Speech recognition algorithms are explored for biometric identifications from one's gait, and I will present and compare the classification performance of the two systems. The acoustic micro-Doppler sonar design and biometric identification results are the first in the field as the previous work used either video camera or microwave technology. I will also review bearing estimation algorithms and present results of applying these algorithms for bearing estimation and tracking of moving vehicles. Another major source of the power consumption at each sensor node is the wireless interface. To address the need of low power communications in a wireless sensor network, I will also discuss the design and implementation of ultra wideband transmitters in a three dimensional

  13. Power and color Doppler ultrasound settings for inflammatory flow

    DEFF Research Database (Denmark)

    Torp-Pedersen, Søren; Christensen, Robin; Szkudlarek, Marcin

    2015-01-01

    OBJECTIVE: To determine how settings for power and color Doppler ultrasound sensitivity vary on different high- and intermediate-range ultrasound machines and to evaluate the impact of these changes on Doppler scoring of inflamed joints. METHODS: Six different types of ultrasound machines were used....... On each machine, the factory setting for superficial musculoskeletal scanning was used unchanged for both color and power Doppler modalities. The settings were then adjusted for increased Doppler sensitivity, and these settings were designated study settings. Eleven patients with rheumatoid arthritis (RA......) with wrist involvement were scanned on the 6 machines, each with 4 settings, generating 264 Doppler images for scoring and color quantification. Doppler sensitivity was measured with a quantitative assessment of Doppler activity: color fraction. Higher color fraction indicated higher sensitivity. RESULTS...

  14. Cooling atoms with extraresonant stimulated emission below the Doppler limit

    International Nuclear Information System (INIS)

    Shevy, Y.

    1989-01-01

    The process of cooling atoms with radiation pressure is well understood in terms of absorption and spontaneous emission of fluorescence photons. This process imposes a lower limit on the minimum equilibrium temperature of laser cooled two level atoms of K b T = ℎΓ 21 /2 (the Doppler limit), where Γ 21 is the excited state decay rate to the ground state. At high laser intensity, it has been demonstrated that the stimulated emission process changes the sign of the force to a heating force at the red side of the atomic resonance and to a cooling force at blue detunings. Although this stimulated force is more efficient than the radiation pressure force, it has been generally accepted that this force cannot lead to lower equilibrium temperatures due to the large heating caused by diffusion of momentum at high intensity. These conclusions are valid only when the sole damping mechanism is the excited state decay to the ground state by spontaneous emission. However, when the atomic system is opened, i.e., is allowed to decay to other levels, or the dipole decay rate is altered by dephasing events, the stimulated force is dramatically modified. Under this conditions the stimulated force can occur at lower laser intensity and can even reverse sign to provide damping at the red side of resonance. These phenomena originate from extraresonances in the stimulated emission process between the two counterpropagating waves. These resonances appear as a dispersive feature in pump probe spectra (Two Wave Mixing) and are closely related to the extraresonances in four wave mixing studied originally by Bloembergen and co-workers. This paper establishes this connection and the potential of these phenomena for laser cooling. The implications of these results to the recently observed ultra-cold Na and Cs atoms are also discussed

  15. Effect of suprathermal electrons on the intensity and Doppler frequency of electron plasma lines

    Directory of Open Access Journals (Sweden)

    P. Guio

    Full Text Available In an incoherent scattering radar experiment, the spectral measurement of the so-called up- and downshifted electron plasma lines provides information about their intensity and their Doppler frequency. These two spectral lines correspond, in the backscatter geometry, to two Langmuir waves travelling towards and away from the radar. In the daytime ionosphere, the presence of a small percentage of photoelectrons produced by the solar EUV of the total electron population can excite or damp these Langmuir waves above the thermal equilibrium, resulting in an enhancement of the intensity of the lines above the thermal level. The presence of photo-electrons also modifies the dielectric response function of the plasma from the Maxwellian and thus influences the Doppler frequency of the plasma lines. In this paper, we present a high time-resolution plasma-line data set collected on the Eiscat VHF radar. The analysed data are compared with a model that includes the effect of a suprathermal electron population calculated by a transport code. By comparing the intensity of the analysed plasma lines data to our model, we show that two sharp peaks in the electron suprathermal distribution in the energy range 20-30 eV causes an increased Landau damping around 24.25 eV and 26.25 eV. We have identified these two sharp peaks as the effect of the photoionisation of N2 and O by the intense flux of monochromatic HeII radiation of wavelength 30.378 nm (40.812 eV created in the chromospheric network and coronal holes. Furthermore, we see that what would have been interpreted as a mean Doppler drift velocity for a Maxwellian plasma is actually a shift of the Doppler frequency of the plasma lines due to suprathermal electrons.

    Key words. Ionosphere (electric fields and currents; solar radiation and cosmic ray effects

  16. Effect of suprathermal electrons on the intensity and Doppler frequency of electron plasma lines

    Directory of Open Access Journals (Sweden)

    P. Guio

    1999-07-01

    Full Text Available In an incoherent scattering radar experiment, the spectral measurement of the so-called up- and downshifted electron plasma lines provides information about their intensity and their Doppler frequency. These two spectral lines correspond, in the backscatter geometry, to two Langmuir waves travelling towards and away from the radar. In the daytime ionosphere, the presence of a small percentage of photoelectrons produced by the solar EUV of the total electron population can excite or damp these Langmuir waves above the thermal equilibrium, resulting in an enhancement of the intensity of the lines above the thermal level. The presence of photo-electrons also modifies the dielectric response function of the plasma from the Maxwellian and thus influences the Doppler frequency of the plasma lines. In this paper, we present a high time-resolution plasma-line data set collected on the Eiscat VHF radar. The analysed data are compared with a model that includes the effect of a suprathermal electron population calculated by a transport code. By comparing the intensity of the analysed plasma lines data to our model, we show that two sharp peaks in the electron suprathermal distribution in the energy range 20-30 eV causes an increased Landau damping around 24.25 eV and 26.25 eV. We have identified these two sharp peaks as the effect of the photoionisation of N2 and O by the intense flux of monochromatic HeII radiation of wavelength 30.378 nm (40.812 eV created in the chromospheric network and coronal holes. Furthermore, we see that what would have been interpreted as a mean Doppler drift velocity for a Maxwellian plasma is actually a shift of the Doppler frequency of the plasma lines due to suprathermal electrons.Key words. Ionosphere (electric fields and currents; solar radiation and cosmic ray effects

  17. Transcranial Doppler sonography in familial hemiplegic migraine

    International Nuclear Information System (INIS)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A.

    1991-01-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab

  18. Color Doppler US of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Bertolotto, Michele (ed.) [Trieste Univ. Ospedale di Cattinara (Italy). Dept. Radiology

    2008-07-01

    This book provides a comprehensive reference and practical guide on the application of US to penile diseases and conditions. After introductory chapters on technical requirements and penile anatomy, subsequent chapters offer a systematic overview of the diverse applications of color Doppler US. The topics covered include erectile dysfunction, Peyronie's disease, priapism, trauma, tumors, the postoperative penis, inflammation, and fibrosis. Each topic is introduced by a clinical overview with the purpose of clarifying the problems and elucidating what the urologist may expect from color Doppler US. Thereafter, performance of the US study is explained and the pathological anatomy reviewed. High-quality images obtained with high-end US equipment are included. Each chapter also contains a section on the diagnostic information provided by other imaging modalities, and in particular MRI. (orig.)

  19. Transcranial Doppler sonography in familial hemiplegic migraine

    Energy Technology Data Exchange (ETDEWEB)

    Pierelli, F.; Pauri, F.; Cupini, L.M.; Fiermonte, G.; Rizzo, P.A. (Universita la Sapienza, Roma (Italy))

    1991-02-01

    A patient affected by familial hemiplegic migraine underwent transcranial Doppler sonography twice: the first during a spontaneous attack with right hemiparesis and aphasia, the second during a headachefree period. During the attack the following haemodynamic changes were seen: (a) bilateral increase in the middle cerebral artery and anterior cerebral artery blood flow velocities (this increase was more pronounced on the left side), (b) decreased systo-diastolic ratio and pulsatility index on the right side, (c) increased systo-diastolic ratio and pulsatility index on the left side. The results indicate that during the attack in this familial hemiplegic migraine patient, a diffuse vasoconstriction of the basal cerebral arteries developed. Moreover, transcranial Doppler sonography data suggest that a prolonged vasoconstriction of the peripheral arterioles could play a role in determining the neurological symptoms in this syndrome. 13 refs., 1 figs., 1 tab.

  20. Renal duplex Doppler ultrasound findings in diabetics

    International Nuclear Information System (INIS)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon

    1993-01-01

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  1. Renal duplex Doppler ultrasound findings in diabetics

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Hyang Yee; Kim, Young Geun; Kook, Cheol Keu; Yoon, Chong Hyun; Lee, Shin Hyung; Lee, Chang Joon [National Medical Center, Seoul (Korea, Republic of)

    1993-12-15

    The correlation between clinical-laboratory findings and renal duplex Doppler ultrasound findings was studied in 45 patients with diabetes mellitus to see the role of duplex Doppler ultrasound in the detection of diabetic nephropathy. The resistive indices in patients with elevated serum creatinine, BUN, proteinuria, and systolic blood pressure levels were statistically significantly higher than those in patients with normal levels (p<0.05). Also resistive indics in patients with retinopathy were higher than that in patients without retinopathy (p<0.05). But the ultrasound morphologic changes of kidney such as renal length, cortical eye-catching, and corticomedullarycontrast were not well correlated with clinical-laboratory data and resistive index. The resistive index of the kidney in conjunction with clinical-laboratory data in diabetics may be helpful in the evaluation of diabetic nephropathy

  2. Directional nonlinear guided wave mixing: Case study of counter-propagating shear horizontal waves

    Science.gov (United States)

    Hasanian, Mostafa; Lissenden, Cliff J.

    2018-04-01

    While much nonlinear ultrasonics research has been conducted on higher harmonic generation, wave mixing provides the potential for sensitive measurements of incipient damage unencumbered by instrumentation nonlinearity. Studies of nonlinear ultrasonic wave mixing, both collinear and noncollinear, for bulk waves have shown the robust capability of wave mixing for early damage detection. One merit of bulk wave mixing lies in their non-dispersive nature, but guided waves enable inspection of otherwise inaccessible material and a variety of mixing options. Co-directional guided wave mixing was studied previously, but arbitrary direction guided wave mixing has not been addressed until recently. Wave vector analysis is applied to study variable mixing angles to find wave mode triplets (two primary waves and a secondary wave) resulting in the phase matching condition. As a case study, counter-propagating Shear Horizontal (SH) guided wave mixing is analyzed. SH wave interactions generate a secondary Lamb wave mode that is readily receivable. Reception of the secondary Lamb wave mode is compared for an angle beam transducer, an air coupled transducer, and a laser Doppler vibrometer (LDV). Results from the angle beam and air coupled transducers are quite consistent, while the LDV measurement is plagued by variability issues.

  3. Time properties of ionospheric wave disturbances

    International Nuclear Information System (INIS)

    Kaliev, M.Z.; Krasnikov, I.M.; Litvinov, Yu.G.; Chakenov, B.D.; Yakovets, A.F.

    1989-01-01

    Records of Doppler frequency shifts of an ionospheric signal, taken in separate observation posts in the vicinity of Alma-Ata in 1986-1987, are analyzed. It is shown that the coherent parts of Doppler shift oscillations are wave disturbance trains in the ionospheric F region. The relation between the train duration and its central frequency is established. With the frequency decrease the mean train length increases, while the maximum train length, determined in the experiment, is about 6h. The probabilities of train detection in the low and high-frequency ranges are nearly the same, and moreover, they are equal in day time and at night

  4. Electromagnetic Cyclotron Waves in the Solar Wind: Wind Observation and Wave Dispersion Analysis

    Science.gov (United States)

    Jian, L. K.; Moya, P. S.; Vinas, A. F.; Stevens, M.

    2016-01-01

    Wind observed long-lasting electromagnetic cyclotron waves near the proton cyclotron frequency on 11 March 2005, in the descending part of a fast wind stream. Bi-Maxwellian velocity distributions are fitted for core protons, beam protons, and alpha-particles. Using the fitted plasma parameters we conduct kinetic linear dispersion analysis and find ion cyclotron and/or firehose instabilities grow in six of 10 wave intervals. After Doppler shift, some of the waves have frequency and polarization consistent with observation, thus may be correspondence to the cyclotron waves observed.

  5. Colour Doppler ultrasound of the penis

    Energy Technology Data Exchange (ETDEWEB)

    Wilkins, C.J.; Sriprasad, S.; Sidhu, P.S. E-mail: paulsidhu@compuserve.com

    2003-07-01

    Because it is a superficial structure, the penis is ideally suited to ultrasound imaging. A number of disease processes, including Peyronie's disease, penile fractures and penile tumours, are clearly visualized with ultrasound. An assessment of priapism can also be made using spectral Doppler waveform technology. Furthermore, dynamic assessment of cavernosal arterial changes after pharmaco-stimulation allows diagnosis of arterial and venogenic causes for impotence. This pictorial review illustrates the range of diseases encountered with ultrasound of the penis.

  6. Doppler Lidar Wind Value-Added Product

    Energy Technology Data Exchange (ETDEWEB)

    Newsom, R. K. [DOE ARM Climate Research Facility, Washington, DC (United States); Sivaraman, C. [DOE ARM Climate Research Facility, Washington, DC (United States); Shippert, T. R. [DOE ARM Climate Research Facility, Washington, DC (United States); Riihimaki, L. D. [DOE ARM Climate Research Facility, Washington, DC (United States)

    2015-07-01

    Wind speed and direction, together with pressure, temperature, and relative humidity, are the most fundamental atmospheric state parameters. Accurate measurement of these parameters is crucial for numerical weather prediction. Vertically resolved wind measurements in the atmospheric boundary layer are particularly important for modeling pollutant and aerosol transport. Raw data from a scanning coherent Doppler lidar system can be processed to generate accurate height-resolved measurements of wind speed and direction in the atmospheric boundary layer.

  7. Shear Wave Elastographic Alterations in the Kidney After Extracorporeal Shock Wave Lithotripsy.

    Science.gov (United States)

    Turkay, Rustu; Inci, Ercan; Bas, Derya; Atar, Arda

    2018-03-01

    Extracorporeal shock wave lithotripsy (ESWL) is a method used frequently for the treatment of renal stone disease. Although its safety is proven, there are still concerns about its unwanted effects on kidneys. In this prospective study, we aimed to evaluate renal tissue alterations with shear wave elastography (SWE) after ESWL. We also studied the correlation between SWE and resistive index (RI) changes. The study included 59 patients who underwent ESWL treatment for renal stone disease. We performed SWE and color Doppler ultrasonography to calculate SWE and RI values before, 1 hour after, and 1 week after lithotripsy treatment. A binary comparison was performed by the Bonferroni test. The correlation between SWE and RI values was evaluated by a Pearson correlation analysis. The patients included 26 women (44.1%) and 33 men (55.9%). Their ages ranged from 20 to 65 years (mean ± SD, 45.0 ± 1.1 years). Stone diameters ranged from 7 to 19 mm (mean, 13.0 ± 0.5 mm). There was a significant difference in SWE values before and 1 hour after lithotripsy treatment (P = .001; P  .99; P > .05). Resistive index values increased significantly 1 hour after lithotripsy treatment and returned to prelithotripsy values 1 week after treatment. In the correlation analysis, SWE and RI values were not correlated. Measurements of alterations in SWE values after ESWL can provide useful information about renal tissue injury. © 2017 by the American Institute of Ultrasound in Medicine.

  8. Frequency shift of the Bragg and Non-Bragg backscattering from periodic water wave

    Science.gov (United States)

    Wen, Biyang; Li, Ke

    2016-08-01

    Doppler effect is used to measure the relative speed of a moving target with respect to the radar, and is also used to interpret the frequency shift of the backscattering from the ocean wave according to the water-wave phase velocity. The widely known relationship between the Doppler shift and the water-wave phase velocity was deduced from the scattering measurements data collected from actual sea surface, and has not been verified under man-made conditions. Here we show that this ob- served frequency shift of the scattering data from the Bragg and Non-Bragg water wave is not the Doppler shift corresponding to the water-wave phase velocity as commonly believed, but is the water-wave frequency and its integral multiple frequency. The power spectrum of the backscatter from the periodic water wave consists of serials discrete peaks, which is equally spaced by water wave frequency. Only when the water-wave length is the integer multiples of the Bragg wave, and the radar range resolution is infinite, does the frequency shift of the backscattering mathematically equal the Doppler shift according to the water-wave phase velocity.

  9. High PRF ultrafast sliding compound doppler imaging: fully qualitative and quantitative analysis of blood flow.

    Science.gov (United States)

    Kang, Jinbum; Jang, Won Seuk; Yoo, Yangmo

    2018-02-09

    Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles (N) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (-12° to 12°) with L of 1-9, and the results were found to be comparable to those of the UCDI method (L  =  N  =  9), i.e.  ⩽0.24 cm s -1 , for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L

  10. High PRF ultrafast sliding compound doppler imaging: fully qualitative and quantitative analysis of blood flow

    Science.gov (United States)

    Kang, Jinbum; Jang, Won Seuk; Yoo, Yangmo

    2018-02-01

    Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles (N) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (-12° to 12°) with L of 1-9, and the results were found to be comparable to those of the UCDI method (L  =  N  =  9), i.e.  ⩽0.24 cm s-1, for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L

  11. Histoscanning and shear wave ultrasound elastography for prostate cancer diagnosis

    Directory of Open Access Journals (Sweden)

    A. V. Amosov

    2016-01-01

    Full Text Available Introduction. The shear wave ultrasound elastography is a recently developed ultrasound-based method in the clinical practice, which allows the qualitative visual and quantitative measurements of tissue stiffness. In the 2010 this technology of the shear wave was called Shear Wave Elastograhpy. Due to the front of the shear waves the qualitative and quantitative assessment of the tissue stiffness is possible.Objective is to examine the efficacy of the shear wave ultrasound elastography in the evaluation of the prevalence of the oncological disease in patients with the prostate cancer and to compare the obtained results with the routine method X-ray diagnostics.Materials and methods. From the april 2015 in the I.M. Sechenov First Moscow State Medical University Urology Clinic there were conducted 314 shear wave ultrasound elastography examinations of the prostate. The ultrasound system Aixplorer® by SuperSonic Imagine was used. This system provides information provided by B-mode and shear wave ultrasound elastography mode. The transrectal echograms were made in 6 dimensions, so called Q-boxes (3 demensions in the every lobe on the segments from the base to the apex, according to the biopsy zone. The unit of measurement was the mean value in the kilopaskals (kPa. All the patients were randomized into 3 groups. There were 146 men with the possible prostate cancer in the first group (prospective study, 120 men with the certain diagnosis of the prostate cancer in the second group (retrospective study and 48 healthy men in the third group (control study. In all the patients of the first and the second groups the routine complete examination, including the prostate specific antigen (PSA level examination, digital rectal examination (DRE, doppler transrectal ultrasonography (TRUS, histoscanning and ultrasound shear wave elastography (SWE, was conducted. In the 229 patients of the first and the second groups the prostatectomy with the

  12. Fast Doppler as a novel bedside measure of cerebral perfusion in preterm infants.

    Science.gov (United States)

    Peeples, Eric S; Mehic, Edin; Mourad, Pierre D; Juul, Sandra E

    2016-02-01

    Altered cerebral perfusion from impaired autoregulation may contribute to the morbidity and mortality associated with premature birth. We hypothesized that fast Doppler imaging could provide a reproducible bedside estimation of cerebral perfusion and autoregulation in preterm infants. This is a prospective pilot study using fast Doppler ultrasound to assess blood flow velocity in the basal ganglia of 19 subjects born at 26-32 wk gestation. Intraclass correlation provided a measure of test-retest reliability, and linear regression of cerebral blood flow velocity and heart rate or blood pressure allowed for estimations of autoregulatory ability. The intraclass correlation when imaging in the first 48 h of life was 0.634. We found significant and independent correlations between the systolic blood flow velocity and both systolic blood pressure and heart rate (P = 0.015 and 0.012 respectively) only in the 26-28 wk gestational age infants in the first 48 h of life. Our results suggest that fast Doppler provides reliable bedside measurements of cerebral blood flow velocity at the tissue level in premature infants, acting as a proxy for cerebral tissue perfusion. Additionally, autoregulation appears to be impaired in the extremely preterm infants, even within a normal range of blood pressures.

  13. UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry in the diagnostics of alopecia

    Science.gov (United States)

    Skomorokha, Diana P.; Pigoreva, Yulia N.; Salmin, Vladimir V.

    2016-04-01

    Development of optical biopsy methods has a great interest for medical diagnostics. In clinical and experimental studies it is very important to analyze blood circulation quickly and accurately, thereby laser Doppler flowmetry (LDF) is widely used. UV laser-induced fluorescence spectroscopy (UV LIFS) is express highly sensitive and widely-spread method with no destructive impact, high excitation selectivity and the possibility to use in highly scattering media. The goal of this work was to assess a correlation of UV laser-induced fluorescence spectroscopy and laser Doppler flowmetry parameters, and a possibility to identify or to differentiate various types of pathological changes in tissues according to their autofluorescence spectra. Three groups of patients with diffuse (symptomatic) alopecia, androgenic alopecia, and focal alopecia have been tested. Each groups consisted of not less than 20 persons. The measurements have been done in the parietal and occipital regions of the sculls. We used the original automated spectrofluorimeter to record autofluorescence spectra, and standard laser Doppler flowmeter BLF-21 (Transonic Systems, Inc., USA) to analyze the basal levels of blood circulation. Our results show that UV LIFS accurately distinguishes the zones with different types of alopecia. We found high correlation of the basal levels of blood circulation and the integrated intensity of autofluorescence in the affected tissue.

  14. Two-dimensional and Doppler echocardiographic findings in healthy non-sedated red-eared slider terrapins (Trachemys scripta elegans).

    Science.gov (United States)

    Poser, H; Russello, G; Zanella, A; Bellini, L; Gelli, D

    2011-12-01

    Echocardiographic evaluation was performed in six healthy young adult non-sedated terrapins (Trachemys scripta elegans). The best imaging quality was obtained through the right cervical window. Base-apex inflow and outflow views were recorded, ventricular size, ventricular wall thickness and ventricular outflow tract were measured, and fractional shortening was calculated. Pulsed-wave Doppler interrogation enabled the diastolic biphasic atrio-ventricular flow and the systolic ventricular outflow patterns to be recorded. The following Doppler-derived functional parameters were calculated: early diastolic (E) and late diastolic (A) wave peak velocities, E/A ratio, ventricular outflow systolic peak and mean velocities and gradients, Velocity-Time Integral, acceleration and deceleration times, and Ejection Time. For each parameter the mean, standard deviation and 95% confidence interval were calculated. Echocardiography resulted as a useful and easy-to-perform diagnostic tool in this poorly known species that presents difficulties during evaluation.

  15. Aortic coarctation diagnosed by renal Doppler flow patterns in a hypertensive young patient: a case report

    International Nuclear Information System (INIS)

    Sari, S.; Kara, K.; Verim, S.

    2012-01-01

    Full text: Introduction: Aortic coarctation is a congenital malformation, which can cause systemic hypertension and subsequent complications, and causes of secondary hypertension, affecting in differential pressures in the upper and lower extremities. Because hypertension is caused by aortic coarctation, tends to be resistant to medical therapy, early recognition and surgical rectification are important. Objectives and tasks: In this article, we aimed to point out that renal Doppler sonography is a beneficial and frequently used to evaluate secondary hypertension, if there are bilateral tardus-parvus wave patterns are detected. Thus, bilateral renal artery stenosis, aortic stenosis, and coarctation should be considered in this condition. Materials and methods: A 23-year-old male who has six-month history of hypertension. He was referred by a cardiologist for investigation of his secondary hypertension. There was an ascending aortic dilatation, left ventricular hypertrophy in his echocardiography. Results: The patient's blood pressure was measured as 160/90 mm Hg in his both arms. Renal Doppler sonography was performed to identify the potential cause of secondary hypertension, specifically renal artery stenosis, after tardus-parvus pulse waves were noted in both renal intralobar-arteries. Aortic coarctation is suspected and then a chest computed tomography (CT) was performed to evaluate supra-diaphragmatic vessel abnormalities. The CT exposed a stenotic lesion in the isthmus of the aorta. The patient was transferred to cardiovascular surgery department for treatment. Conclusion: Careful physical examination should be performed in all hypertensive patients. If bilateral tardus-parvus wave pattern are seen in patients who has been referred for Doppler evaluation on suspicion of renovascular hypertension, aortic coarctation should be considered as differential diagnosis

  16. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  17. Doppler ultrasonography of the pectinis oculi artery in harpy eagles (Harpia harpyja

    Directory of Open Access Journals (Sweden)

    Wanderlei de Moraes

    2017-03-01

    Full Text Available Twenty harpy eagles (Harpia harpyja without systemic or ocular diseases were examined to measure blood velocity parameters of the pectinis oculi artery using Doppler ultrasonography. Pectinate artery resistive index (RI and pulsatility index (PI were investigated using ocular Doppler ultrasonography. The mean RI and PI values across all eyes were 0.44±0.10 and 0.62±0.20 respectively. Low RI and PI values found in the harpy eagle´s pectinis oculi artery compared with the American pekin ducks one and other tissue suggest indeed a high metabolic activity in pecten oculi and corroborates the hypothesis of a nutritional function and/or intraocular pressure regulation.

  18. Invasive and noninvasive assessment of pulmonic regurgitation: clinical, angiographic, phonocardiographic, echocardiographic, and Doppler ultrasound correlations.

    Science.gov (United States)

    Chandraratna, P A; Wilson, D; Imaizumi, T; Ritter, W S; Aronow, W S

    1982-06-01

    Three patients with pulmonic regurgitation and no evidence of pulmonary hypertension were investigated. These patients had low pitched diastolic murmurs which increased on inspiration, evidence of connective tissue disease as manifested by lax joints and hyperextensible skin, and marked hilar dance which extended up to the peripheral vessels. Suprasternal echocardiography revealed dilatation and increased systolic expansion of the right pulmonary artery (RPA) (25% and 28%, respectively) in two patients; the third patient had a normal RPA dimension in diastole and a marked increase in diameter (88%) in systole. Thus, these three patients demonstrated hyperdistensibility of the RPA. The spectral signal from the pulsed doppler echocardiograph showed evidence of turbulent blood flow in diastole (wide dispersion of the dots) in the right ventricular outflow tract in all three patients. This pattern was indicative of pulmonic regurgitation. In summary, the combined use of echocardiography and Doppler ultrasound is useful in the evaluation of patients with pulmonic regurgitation.

  19. Middle Atmosphere Dynamics with Gravity Wave Interactions in the Numerical Spectral Model: Tides and Planetary Waves

    Science.gov (United States)

    Mayr, Hans G.; Mengel, J. G.; Chan, K. L.; Huang, F. T.

    2010-01-01

    As Lindzen (1981) had shown, small-scale gravity waves (GW) produce the observed reversals of the zonal-mean circulation and temperature variations in the upper mesosphere. The waves also play a major role in modulating and amplifying the diurnal tides (DT) (e.g., Waltersheid, 1981; Fritts and Vincent, 1987; Fritts, 1995a). We summarize here the modeling studies with the mechanistic numerical spectral model (NSM) with Doppler spread parameterization for GW (Hines, 1997a, b), which describes in the middle atmosphere: (a) migrating and non-migrating DT, (b) planetary waves (PW), and (c) global-scale inertio gravity waves. Numerical experiments are discussed that illuminate the influence of GW filtering and nonlinear interactions between DT, PW, and zonal mean variations. Keywords: Theoretical modeling, Middle atmosphere dynamics, Gravity wave interactions, Migrating and non-migrating tides, Planetary waves, Global-scale inertio gravity waves.

  20. Laser-Doppler acoustic probing of granular media with in-depth property gradient and varying pore pressures

    International Nuclear Information System (INIS)

    Bodet, L.; Dhemaied, A.; Mourgues, R.; Tournat, V.; Rejiba, F.

    2012-01-01

    Non-contacting ultrasonic techniques recently proved to be efficient in the physical modeling of seismic-wave propagation at various application scales, as for instance in the context of geological analogue and seismic modeling. An innovative experimental set-up is proposed here to perform laser-Doppler acoustic probing of unconsolidated granular media with varying pore pressures. The preliminary experiments presented here provide reproducible results and exploitable data, thus validating both the proposed medium preparation and pressure gradient generation procedure.

  1. Distinguishing Buried Objects in Extremely Shallow Underground by Frequency Response Using Scanning Laser Doppler Vibrometer

    Science.gov (United States)

    Touma Abe,; Tsuneyoshi Sugimoto,

    2010-07-01

    A sound wave vibration using a scanning laser Doppler vibrometer are used as a method of exploring and imaging an extremely shallow underground. Flat speakers are used as a vibration source. We propose a method of distinguishing a buried object using a response range of a frequencies corresponding to a vibration velocities. Buried objects (plastic containers, a hollow steel can, an unglazed pot, and a stone) are distinguished using a response range of frequencies. Standardization and brightness imaging are used as methods of discrimination. As a result, it was found that the buried objects show different response ranges of frequencies. From the experimental results, we confirmed the effectiveness of our proposed method.

  2. Performance evaluation of an all-fiber image-reject homodyne coherent Doppler wind lidar

    DEFF Research Database (Denmark)

    Abari, Cyrus F.; Pedersen, Anders Tegtmeier; Dellwik, Ebba

    2015-01-01

    The main purpose of this study is to evaluate the near-zero wind velocity measurement performance of two separate 1.5 µm all-fiber coherent Doppler lidars (CDLs). The performance characterization is carried out through the presentation of the results from two separate atmospheric field campaigns....... In one campaign, a recently developed continuous wave (CW) CDL benefiting from an image-reject front-end was deployed. The other campaign utilized a different CW CDL, benefiting from a heterodyne receiver with intermediate-frequency (IF) sampling. In both field campaigns the results are compared against...

  3. The image of urachus adenocarcinoma on Doppler ultrasonography

    Energy Technology Data Exchange (ETDEWEB)

    Oyar, Orhan E-mail: o_oyar@hotmail.com; Yesildag, Ahmet; Gulsoy, Ufuk Kemal; Perk, Hakki

    2002-10-01

    Malignant urachal lesions are exceedingly rare and occur predominantly in adult life. In this case report, an adult patient with urachal carcinoma is presented with abdominal plain film, intravenous urography, gray-scale ultrasonography (US), Doppler US, and computed tomography (CT). Doppler US successfully showed the neovascularity with low resistive index value in the urachus tumor. We believe that Doppler US examination is helpful in the differential diagnosis of urachal carcinoma.

  4. Doppler US evaluation of the hypertensive portal system

    International Nuclear Information System (INIS)

    Needleman, L.; Kurtz, A.B.; Bezzi, M.; Rifkin, M.D.; Pasto, M.E.; Pennell, R.G.; Baltarowich, O.H.; Goldberg, B.B.

    1986-01-01

    In patients with known portal hypertension, pulsed Doppler US was used for qualitative and directional evaluation of flow in the portal venous system and collateral vessels. Most patients had normal hepatopetal flow. Doppler US revealed the following abnormal blood flow patterns: hepatofugal portal flow, bidirectional portal flow, intrahepatic portal shunting, flow in portasystemic collaterals, and hepatic vein obstruction. Doppler US can provide important clinical information in the evaluation of portal hypertension

  5. New Insights from Inside-Out Doppler Tomography

    Directory of Open Access Journals (Sweden)

    E. J. Kotze

    2015-02-01

    Full Text Available We present preliminary results from our investigation into using an “inside-out” velocity space for creating a Doppler tomogram. The aim is to transpose the inverted appearance of the Cartesian velocity space used in normal Doppler tomography. In a comparison between normal and inside-out Doppler tomograms of cataclysmic variables, we show that the inside-out velocity space has the potential to produce new insights into the accretion dynamics in these systems.

  6. Power doppler 'blanching' after the application of transducer pressure

    International Nuclear Information System (INIS)

    Joshua, F.; Edmonds, J.; Lassere, M.; De Carle, R.; Rayment, M.; Bryant, C.; Shnier, R.

    2005-01-01

    The aim of this study was to determine if transducer pressure modifies power Doppler assessments of rheumatoid arthritis synovium at the metacarpophalangeal joints and metatarsophalangeal joints. Five rheumatoid arthritis patients of varying degrees of 'disease activity' and damage were assessed with power Doppler ultrasound scanning of the dominant hand second to fifth metacarpophalangeal joints. Two rheumatoid arthritis patients had their dominant foot first to fifth metatarsophalangeal joints assessed with power Doppler ultrasound. Ultrasonography was performed with a high frequency transducer (14 MHz) with a colour mode frequency of 10 Mhz, and a standard colour box and gain. In the joint that showed the highest power Doppler signal, an image was made. A further image was taken after transducer pressure was applied. In all patients, there was increased flow to at least one joint. After pressure was applied, power Doppler signal intensity markedly reduced in all images and in some there was no recordable power Doppler signal. Increased transducer pressure can result in a marked reduction or obliteration in power Doppler signal. This power Doppler 'blanching' shows the need for further studies to evaluate sources of error and standardization before power Doppler ultrasound becomes a routine measure of 'disease activity' in rheumatoid arthritis. Copyright (2005) Blackwell Science Pty Ltd

  7. Evaluating Peripheral Vascular Injuries: Is Color Doppler Enough for Diagnosis?

    Directory of Open Access Journals (Sweden)

    Mohd Lateef Wani

    2014-03-01

    Full Text Available Background:: Vascular injury poses a serious threat to limb and life. Thus, diagnosis should be made immediately with minimally invasive methods. Doppler is a good aid in diagnosis of vascular injury. Methods:: The present prospective study was conducted on 150 patients who presented with soft signs (the signs which are suggestive but not confirmatory of vascular injury. They were subjected to color Doppler examination before exploration. The patients with the features of vascular injury on color Doppler were subjected to exploration. On the other hand, those who had normal Doppler were subjected to CT- angiography. Then, the findings of the exploration were matched with those of color Doppler. The data were analyzed using the SPSS statistical software. Results:: Out of the 150 Doppler examinations, 110 (73.33% were reported as positive, while 40 were reported as negative for vascular injury. These were subjected to CT-angiography and seven of them had the features of vascular injury on CT-angiography. All the patients with positive Doppler or CT angiography findings were subjected to exploration. Doppler had a sensitivity of 94% and specificity of 82.5% in diagnosis of vascular injury using Binary classification test. Conclusions:: Color Doppler is an easily available, reliable, and handy method of diagnosing a vascular injury. It has a very high sensitivity and specificity in diagnosis of vascular injuries.

  8. Detection of a stochastic background of gravitational radiation by the Doppler tracking of spacecraft

    International Nuclear Information System (INIS)

    Mashhoon, B.; Grishchuk, L.P.

    1980-01-01

    The possibility of detection of an isotropic background gravitational radiation of a stochastic nature by the method of Doppler tracking of spacecraft is considered. In the geometrical optics limit, the general formula for the frequency shift of an electromagnetic signal in the gravitational radiation field is discussed, and it is shown to be gauge (or rather Lie) independent. A detailed examination of the propagation of a free electromagnetic wave in a gravitational radiation field shows that no resonance phenomena can be expected. Thus, the results valid in the geometrical optics limit are also approximately valid for any gravitational radiation spectrum dominated by wavelengths large compared to that of the electromagnetic signal. The ''Doppler noise'' due to a stochastic background is evaluated, and it is shown to depend on the total energy density of the background and a parameter that is a characteristic of the aradiation spectrum and the detection system used. A background gravitational radiation with an energy density comparable to the electromagnetic (approx.3 K) background and a spectrum dominated by wavelengths > or approx. =1 AU may be detectable in the near future by the Doppler tracking of interplanetary spacecraft

  9. B-mode and Doppler ultrasonography of adrenal glands of healthy dogs

    Directory of Open Access Journals (Sweden)

    S. Fernandez

    2016-08-01

    Full Text Available ABSTRACT The aim of this study was to determine the vascular indices of adrenal blood flow in healthy dogs (systolic velocity - SV; diastolic velocity - DV; resistance index - RI. Eighteen dogs (thirty six adrenal were studied. Physical examination, biochemical profile and dexamethasone suppression test were performed to determine general health status. Echotexture, size, contours and margins, and overall shape of the adrenal gland (right and left were assessed via ultrasound. By spectral Doppler of the phrenic-abdominal artery, the SV, DV, and RI were acquired. Animals did not show alterations in clinical and laboratory examination and suppression of cortisol. Normal homogeneous and echotexture, regular contours and margins and normal shape and size were verified via B mode. Spectral Doppler of the phrenic-abdominal artery showed monophasic-patterned waves and low vascular resistance and systolic peak evident with means values: left adrenal - SV = 31.34cm/s, DV = 9.54cm/s and RI = 0.69; and right adrenal - SV = 27.83cm/s, DV = 7.71cm/s and RI = 0.68. Doppler evaluation of adrenal was easily implemented and may provide base line data in the study, allowing for the use of this technique as a diagnostic tool for diseases of the dog's adrenal.

  10. Doppler optical coherence microscopy and tomography applied to inner ear mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Page, Scott; Freeman, Dennis M. [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Ghaffari, Roozbeh [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States)

    2015-12-31

    While it is clear that cochlear traveling waves underlie the extraordinary sensitivity, frequency selectivity, and dynamic range of mammalian hearing, the underlying micromechanical mechanisms remain unresolved. Recent advances in low coherence measurement techniques show promise over traditional laser Doppler vibrometry and video microscopy, which are limited by low reflectivities of cochlear structures and restricted optical access. Doppler optical coherence tomography (DOCT) and Doppler optical coherence microscopy (DOCM) both utilize a broadband source to limit constructive interference of scattered light to a small axial depth called a coherence gate. The coherence gate can be swept axially to image and measure sub-nanometer motions of cochlear structures throughout the cochlear partition. The coherence gate of DOCT is generally narrower than the confocal gate of the focusing optics, enabling increased axial resolution (typically 15 μm) within optical sections of the cochlear partition. DOCM, frequently implemented in the time domain, centers the coherence gate on the focal plane, achieving enhanced lateral and axial resolution when the confocal gate is narrower than the coherence gate. We compare these two complementary systems and demonstrate their utility in studying cellular and micromechanical mechanisms involved in mammalian hearing.

  11. Digital setup for Doppler broadening spectroscopy

    International Nuclear Information System (INIS)

    Cizek, J; Vlcek, M; Prochazka, I

    2011-01-01

    New digital spectrometer for measurement of the Doppler shift of annihilation photons was developed and tested in this work. Digital spectrometer uses a fast 12-bit digitizer for direct sampling of signals from HPGe detectors. Analysis of sampled waveforms is performed off-line in software. Performance of the new digital setup was compared with its traditional analogue counterpart. Superior energy resolution was achieved in the digital setup. Moreover, the digital setup allows for a better control of the shape of detector signals. This enables to eliminate undesired signals damaged by pile-up effects or by ballistic deficit.

  12. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Luca Giugno

    2007-05-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  13. Relationship between liver tissue stiffness and histopathological findings analyzed by shear wave elastography and compression testing in rats with non-alcoholic steatohepatitis.

    Science.gov (United States)

    Ogawa, Saori; Moriyasu, Fuminori; Yoshida, Keiko; Oshiro, Hisashi; Kojima, Mayumi; Sano, Takatomo; Furuichi, Yoshihiro; Kobayashi, Yoshiyuki; Nakamura, Ikuo; Sugimoto, Katsutoshi

    2016-07-01

    The aim of the present study was to investigate two methods of determining liver stiffness in rats with various degrees of non-alcoholic steatohepatitis induced by a methionine- and choline-deficient (MCD) diet by comparing each finding with reference to histopathological liver findings. Twenty male Wister rats were fed an MCD diet for up to 32 weeks, and four were fed a normal diet. Ultrasound-based shear wave elastography (SWE) and mechanical compression testing using an Instron Universal Testing machine were performed on each rat at designated time points. After each examination, liver histopathology was analyzed to evaluate the degrees of steatosis, inflammation, and fibrosis based on non-alcoholic fatty liver disease (NAFLD) activity score, and each finding was compared with reference to liver histopathologic findings. Median liver stiffness values measured using SWE showed a stepwise increase with increasing histological inflammation score (P = 0.002), hepatic fibrosis stage (P = 0.029), ballooning score (P = 0.012), and steatosis grade (P = 0.030). Median liver stiffness measured using an Instron machine showed a stepwise increase only with increasing histological fibrosis stage (P = 0.033). Degree of liver stiffness measured by SWE and the Instron machine differed. SWE reflected mainly inflammation, whereas Instron machine-derived values primarily reflected fibrosis. This is the main source of discrepancies between measurements made with these two modalities.

  14. Diagnostic value of Doppler echocardiography for identifying hemodynamic significant pulmonary valve regurgitation in tetralogy of Fallot: comparison with cardiac MRI.

    Science.gov (United States)

    Beurskens, Niek E G; Gorter, Thomas M; Pieper, Petronella G; Hoendermis, Elke S; Bartelds, Beatrijs; Ebels, Tjark; Berger, Rolf M F; Willems, Tineke P; van Melle, Joost P

    2017-11-01

    Quantification of pulmonary regurgitation (PR) is essential in the management of patients with repaired tetralogy of Fallot (TOF). We sought to evaluate the accuracy of first-line Doppler echocardiography in comparison with cardiac magnetic resonance imaging (MRI) to identify hemodynamic significant PR. Paired cardiac MRI and echocardiographic studies (n = 97) in patients with repaired TOF were retrospectively analyzed. Pressure half time (PHT) and pulmonary regurgitation index (PRi) were measured using continuous wave Doppler. The ratio of the color flow Doppler regurgitation jet width to pulmonary valve (PV) annulus (jet/annulus ratio) and diastolic to systolic time velocity integral (DSTVI; pulsed wave Doppler) were assessed. Accuracy of echocardiographic measurements was tested to identify significant PR as determined by phase-contrast MRI (PR fraction [PRF] ≥ 20%). Mean PRF was 29.4 ± 15.7%. PHT < 100 ms had a sensitivity of 93%, specificity 75%, positive predictive value (PPV) 92% and negative predictive value (NPV) 78% for identifying significant PR (C-statistic 0.82). PRi < 0.77 had sensitivity and specificity of 66% and 54%, respectively (C-statistic 0.63). Jet/annulus ratio ≥1/3 had sensitivity 96%, specificity 75%, PPV 92% and NPV 82% (C-statistic 0.87). DSTVI had sensitivity 84%, specificity 33%, PPV 84% and NPV 40%, (C-statistic 0.56). Combined jet/annulus ratio ≥1/3 and PHT < 100 ms was highly accurate in identifying PRF ≥ 20%, with sensitivity 97% and specificity 100%. PHT and jet/annulus ratio on Doppler echocardiography, especially when combined, are highly accurate in identifying significant PR and therefore seem useful in the follow-up of patients with repaired TOF.

  15. Doppler ultrasound scan during normal gestation: umbilical circulation; Ecografia Doppler en la gestacion normal: circulacion umbilical

    Energy Technology Data Exchange (ETDEWEB)

    Ruiz, T.; Sabate, J.; Martinez-Benavides, M. M.; Sanchez-Ramos, J. [Hospital Virgen Macarena. Sevilla (Spain)

    2002-07-01

    To determine normal umbilical circulation patterns by means of Doppler ultrasound scan in a healthy gestating population without risk factors and with normal perinatal results, and to evaluate any occurring modifications relative to gestational age by obtaining records kept during pregnancy. One hundred and sixteen pregnant women carrying a single fetus have been studied. These women had no risk factors, with both clinical and analytical controls, as well as ultrasound scans, all being normal. There were performed a total of 193 Doppler ultrasound scans between weeks 15 and 41 of gestation, with blood-flow analysis in the arteries and vein of the umbilical cord. The obtained information was correlated with parameters that evaluate fetal well-being (fetal monitoring and/or oxytocin test) and perinatal result (delivery type, birth weight, Apgar score). Statistical analysis was performed with the programs SPSS 6.0.1 for Windows and EPIINFO 6.0.4. With pulsed Doppler, the umbilical artery in all cases demonstrated a biphasic morphology with systolic and diastolic components and without retrograde blood flow. As the gestation period increased, there was observed a progressive decrease in resistance along with an increase in blood-flow velocity during the diastolic phase. The Doppler ultrasound scan is a non-invasive method that permits the hemodynamic study of umbilical blood circulation. A knowledge of normal blood-flow signal morphology, as well as of the normal values for Doppler indices in relation to gestational age would permit us to utilize this method in high-risk pregnancies. (Author) 30 refs.

  16. Ambiguity resolution for satellite Doppler positioning systems

    Science.gov (United States)

    Argentiero, P.; Marini, J.

    1979-01-01

    The implementation of satellite-based Doppler positioning systems frequently requires the recovery of transmitter position from a single pass of Doppler data. The least-squares approach to the problem yields conjugate solutions on either side of the satellite subtrack. It is important to develop a procedure for choosing the proper solution which is correct in a high percentage of cases. A test for ambiguity resolution which is the most powerful in the sense that it maximizes the probability of a correct decision is derived. When systematic error sources are properly included in the least-squares reduction process to yield an optimal solution the test reduces to choosing the solution which provides the smaller valuation of the least-squares loss function. When systematic error sources are ignored in the least-squares reduction, the most powerful test is a quadratic form comparison with the weighting matrix of the quadratic form obtained by computing the pseudoinverse of a reduced-rank square matrix. A formula for computing the power of the most powerful test is provided. Numerical examples are included in which the power of the test is computed for situations that are relevant to the design of a satellite-aided search and rescue system.

  17. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan [Kangnam General Hospital Public Corporation, Seoul (Korea, Republic of); Hwang, Hee Yong [Choong Ang Gil Hospital, Incheon (Korea, Republic of)

    1995-06-15

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  18. Enormous periodic doppler shifts in SS 433

    International Nuclear Information System (INIS)

    Margon, B.; Ford, H.C.; Grandi, S.A.; Stone, R.P.S.

    1979-01-01

    We have previously reported prominent ''moving' emission lines in the visible spectrum of Stephenson-Sanduleak 433, the optical counterpart of a variable radio and X-ray source. Further observations show that despite the implausible velocities and changes in velocities implied if the moving features are interpreted as Doppler-shifted Balmer lines, this explanation is indeed correct. Spectroscopy of SS 433 on 51 mights in 1978--1979 reveals that the unidentified features are two sets of Balmer and He I lines, one with large and changing redshift, and the other with large and changing blueshift. Combining our data with published earlier observations, we obtain Doppler shifts on 80 nights in the period 1978 June to 1979 June. These data indicate that the velocity variations are cyclical, repeating in both the blueshift and redshift systems with a period of 164 +- 3 days. The two systems have thus far been observed to reach maximum positive and negative radial velocities of +50,000 and -35,000 km s -1 , respectively, are always symmetric about redshift z=0.04, and follow roughly sinusoidal velocity curves. We discuss in addition a variety of interesting short-term spectroscopic details, including minor but highly significant deviations of the radial velocity from the sinusoid, and nightly line profile changes, sometimes appearing as mirror-image events in the redshift and blueshift systems. The behavior of SS 433 is unprecedented

  19. Speed of light demonstration using Doppler beat

    Science.gov (United States)

    Bernal, Luis; Bilbao, Luis

    2018-05-01

    From an apparatus previously designed for measuring the Doppler shift using a rotating mirror, an improved, versatile version was developed for speed of light demonstrations in a classroom or a teaching laboratory. By adding a second detector and adequate beam-splitter and mirrors, three different configurations are easily assembled. One configuration is used for time-of-flight measurements between a near and a far detector, allowing one to measure the speed of light provided that the path length between detectors is known. Another variation is the interferometric method obtained by superposing the far and near signals in such a way that a minimum of the combined signal is obtained when the time delay makes the signals arrive out of phase by π radians. Finally, the standard Doppler configuration allows the measurement of the frequency beat as a function of the rotation frequency. The main advantages of the apparatus are (a) the experimental setup is simple and completely accessible to undergraduate students, (b) the light is visible, students can see the rays, which, with the use of appropriate screens, can be blocked at any point along their paths, (c) the experiment can take place entirely within the teaching laboratory or demonstration room (using the interferometric method, the shortest distance to the far mirror was as small as 0.5 m), and (d) different configurations can be built, including some economical setups within the budget of teaching laboratories.

  20. Laser doppler velocimetry and confined flows

    Directory of Open Access Journals (Sweden)

    Ilić Jelena T.

    2017-01-01

    Full Text Available Finding the mode, in which two component laser Doppler velocimetry can be applied to flows confined in cylindrical tubes or vessels, was the aim of this study. We have identified principle issues that influence the propagation of laser beams in laser Doppler velocimetry system, applied to flow confined in cylindrical tube. Among them, the most important are influences of fluid and wall refractive indices, wall thickness and internal radius ratio and beam intersection angle. In analysis of the degrees of these influences, we have applied mathematical model, based on geometrical optics. The separation of measurement volumes, that measure different velocity components, has been recognized as the main drawback. To overcome this, we propose a lens with dual focal length – primary focal length for the measurement of one velocity component and secondary focal length for the measurement of the other velocity component. We present here the procedure for calculating the optimal value of secondary focal length, depending on experimental set-up parameters. The mathematical simulation of the application of the dual focal length lens, for chosen cases presented here, confirmed the accuracy of the proposed procedure.

  1. Color Doppler Ultrasonographic Features of Hashimoto's Thyroiditis

    International Nuclear Information System (INIS)

    Lee, Joo Hyuk; Kim, Mie Young; Rho, Eun Jin; Yi, Jeong Geun; Han, Chun Hwan; Hwang, Hee Yong

    1995-01-01

    Color Doppler ultrasonographic(US) features of 28 patients with Hashimato's thyroiditis were evaluated with regard to echo and color-flow patterns. Correlation of color-flow pattern with thyroid function was performed. All 28 patients showed varying degrees of diffuse enlargement of the thyroid gland and a heterogeneous echo pattern.Color-flow pattern of increased blood flow. Low to moderate, focally increased blood flow was seen in 26 patients(92.8%). Of these 26 patients, 24 patients showed subclinical hypothyroidism or euthyroidism. Two patients who showed hyperthyroidism showed several pieces of focally increased color flow, Which was noted during both systole and diastole. Diffuse, multifocal color-flow throughout thyroid gland was seen in two patients with Hashimato's thyroiditis: one with clinical hypothyroidism and the other with subclinical hypothyroidism. Even though Hashimoto's thyroiditis showed variable color-flow patterns, we believe that heterogenous parenchymal echopattern with low or moderately increased flow is a rather characteristic feature of Hashimoto's thyroiditis, and we suggest that color Doppler US provides additional information for evaluation of Hashimoto's thyroiditis

  2. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    Directory of Open Access Journals (Sweden)

    Lawrence H. Lin

    Full Text Available Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: “Gestational trophoblastic disease AND Ultrasonography, Doppler.” Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1 Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2 There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3 Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4 Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. CONCLUSION: Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  3. Is Doppler ultrasound useful for evaluating gestational trophoblastic disease?

    Science.gov (United States)

    Lin, Lawrence H; Bernardes, Lisandra S; Hase, Eliane A; Fushida, Koji; Francisco, Rossana P V

    2015-12-01

    Doppler ultrasound is a non-invasive method for evaluating vascularization and is widely used in clinical practice. Gestational trophoblastic neoplasia includes a group of highly vascularized malignancies derived from placental cells. This review summarizes data found in the literature regarding the applications of Doppler ultrasound in managing patients with gestational trophoblastic neoplasia. The PubMed/Medline, Web of Science, Cochrane and LILACS databases were searched for articles published in English until 2014 using the following keywords: "Gestational trophoblastic disease AND Ultrasonography, Doppler." Twenty-eight articles met the inclusion criteria and were separated into the 4 following groups according to the aim of the study. (1) Doppler ultrasound does not seem to be capable of differentiating partial from complete moles, but it might be useful when evaluating pregnancies in which a complete mole coexists with a normal fetus. (2) There is controversy in the role of uterine artery Doppler velocimetry in the prediction of development of gestational trophoblastic neoplasia. (3) Doppler ultrasound is a useful tool in the diagnosis of gestational trophoblastic neoplasia because abnormal myometrial vascularization and lower uterine artery Doppler indices seem to be correlated with invasive disease. (4) Lower uterine artery Doppler indices in the diagnosis of gestational trophoblastic neoplasia are associated with methotrexate resistance and might play a role in prognosis. Several studies support the importance of Doppler ultrasound in the management of patients with gestational trophoblastic neoplasia, particularly the role of Doppler velocimetry in the prediction of trophoblastic neoplasia and the chemoresistance of trophoblastic tumors. Doppler findings should be used as ancillary tools, along with human chorionic gonadotropin assessment, in the diagnosis of gestational trophoblastic neoplasia.

  4. The effect of blood acceleration on the ultrasound power Doppler spectrum

    Science.gov (United States)

    Matchenko, O. S.; Barannik, E. A.

    2017-09-01

    The purpose of the present work was to study the influence of blood acceleration and time window length on the power Doppler spectrum for Gaussian ultrasound beams. The work has been carried out on the basis of continuum model of the ultrasound scattering from inhomogeneities in fluid flow. Correlation function of fluctuations has been considered for uniformly accelerated scatterers, and the resulting power Doppler spectra have been calculated. It is shown that within the initial phase of systole uniformly accelerated slow blood flow in pulmonary artery and aorta tends to make the correlation function about 4.89 and 7.83 times wider, respectively, than the sensitivity function of typical probing system. Given peak flow velocities, the sensitivity function becomes, vice versa, about 4.34 and 3.84 times wider, respectively, then the correlation function. In these limiting cases, the resulting spectra can be considered as Gaussian. The optimal time window duration decreases with increasing acceleration of blood flow and equals to 11.62 and 7.54 ms for pulmonary artery and aorta, respectively. The width of the resulting power Doppler spectrum is shown to be defined mostly by the wave vector of the incident field, the duration of signal and the acceleration of scatterers in the case of low flow velocities. In the opposite case geometrical properties of probing field and the average velocity itself are more essential. In the sense of signal-noise ratio, the optimal duration of time window can be found. Abovementioned results may contribute to the improved techniques of Doppler ultrasound diagnostics of cardiovascular system.

  5. Differences between Doppler velocities of ions and neutral atoms in a solar prominence

    Science.gov (United States)

    Anan, T.; Ichimoto, K.; Hillier, A.

    2017-05-01

    Context. In astrophysical systems with partially ionized plasma, the motion of ions is governed by the magnetic field while the neutral particles can only feel the magnetic field's Lorentz force indirectly through collisions with ions. The drift in the velocity between ionized and neutral species plays a key role in modifying important physical processes such as magnetic reconnection, damping of magnetohydrodynamic waves, transport of angular momentum in plasma through the magnetic field, and heating. Aims: This paper aims to investigate the differences between Doppler velocities of calcium ions and neutral hydrogen in a solar prominence to look for velocity differences between the neutral and ionized species. Methods: We simultaneously observed spectra of a prominence over an active region in H I 397 nm, H I 434 nm, Ca II 397 nm, and Ca II 854 nm using a high dispersion spectrograph of the Domeless Solar Telescope at Hida observatory. We compared the Doppler velocities, derived from the shift of the peak of the spectral lines presumably emitted from optically-thin plasma. Results: There are instances when the difference in velocities between neutral atoms and ions is significant, for example 1433 events ( 3% of sets of compared profiles) with a difference in velocity between neutral hydrogen atoms and calcium ions greater than 3σ of the measurement error. However, we also found significant differences between the Doppler velocities of two spectral lines emitted from the same species, and the probability density functions of velocity difference between the same species is not significantly different from those between neutral atoms and ions. Conclusions: We interpreted the difference of Doppler velocities as being a result of the motions of different components in the prominence along the line of sight, rather than the decoupling of neutral atoms from plasma. The movie attached to Fig. 1 is available at http://www.aanda.org

  6. Color Doppler ultrasound evaluation of asphyxial neonatal left ventricular function and its correlation with target organ damage

    Directory of Open Access Journals (Sweden)

    Cheng-Cai Chen

    2017-01-01

    Full Text Available Objective: To study the color Doppler ultrasound parameters of asphyxial neonatal left ventricular function and the correlation with target organ damage. Methods: Normal neonates, mildly asphyxial neonates and severely asphyxial neonates born in our hospital between January 2014 and December 2015 were selected as the control group (n = 46, mild asphyxia group (n = 37 and severe asphyxia group (n = 23 respectively. On the 1st day after birth, color Doppler ultrasound was used to evaluate left ventricular function, and serum was collected to determine myocardial tissue injury, brain tissue injury and brain tissue metabolism indexes. Results: Color Doppler ultrasound parameters cardiac output (CO, ejection fraction (EF and left ventricular fraction shortening (FS as well as serum folate and vitamin B12 content of mild asphyxia group and severe asphyxia group were significantly lower than those of control group (P<0.05 while serum creatine kinase isoenzyme (CK-MB, troponin I (cTnI, troponin T (cTnT, S100B, neuron-specific enolase (NSE, creatine kinase BB (CK-BB, glycogen phosphorylase BB (GPBB, and homocysteine (Hcy content were significantly higher than those of control group (P<0.05; CO, FS and EF as well as serum folate and vitamin B12 content of severe asphyxia group were significantly lower than those of mild asphyxia group (P<0.05 while serum CK-MB, cTnT, cTnI, S100B, NSE, CK-BB, GPBB and Hcy content were significantly higher than those of mild asphyxia group (P<0.05. Conclusions: Color Doppler ultrasound can accurately assess asphyxial neonatal left ventricular function damage degree and is closely related to myocardial tissue injury and brain tissue injury degree.

  7. The effectiveness of Doppler controlled hemorrhoidal artery ligation ...

    African Journals Online (AJOL)

    In this work, we discuss the preliminary results of the effectiveness of the hemorrhoidal artery ligation under control Doppler as a new technique for the treatment of hemorrhoids. We report the results of patients with hemorrhoids we have followed over a period of one year who were treated with HAL Doppler. The intra-and ...

  8. Musculoskeletal colour/power Doppler in sports medicine

    DEFF Research Database (Denmark)

    Boesen, M I; Boesen, M; Langberg, Henning

    2010-01-01

    This review article discusses the aspects of sports medicine where musculoskeletal Doppler ultrasound has valuable contribution in diagnosis and/or treatment of some of the typical musculoskeletal sports injuries. Also, conditions where the Doppler ultrasound has no value are discussed. Some...

  9. 21 CFR 892.1550 - Ultrasonic pulsed doppler imaging system.

    Science.gov (United States)

    2010-04-01

    ... system. (a) Identification. An ultrasonic pulsed doppler imaging system is a device that combines the... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic pulsed doppler imaging system. 892.1550... include signal analysis and display equipment, patient and equipment supports, component parts, and...

  10. Micro-Doppler classification of riders and riderless horses

    Science.gov (United States)

    Tahmoush, David

    2014-05-01

    Micro-range Micro-Doppler can be used to isolate particular parts of the radar signature, and in this case we demonstrate the differences in the signature between a walking horse versus a walking horse with a rider. Using micro-range micro-Doppler, we can distinguish the radar returns from the rider as separate from the radar returns of the horse.

  11. Correlation between Spectral Index and Doppler Factor for a ...

    Indian Academy of Sciences (India)

    Abstract. Relativistic beaming effect is important for blazars. In a very recent work, γ-ray Doppler factors were calculated for a sample of Fermi blazars (Fan et al. 2013). In this work, we investigated the correlation between the Doppler factor and the effective spectral index, αOX, and found an anticorrelation between them.

  12. Compressive sensing for high resolution profiles with enhanced Doppler performance

    NARCIS (Netherlands)

    Anitori, L.; Hoogeboom, P.; Chevalier, F. Le; Otten, M.P.G.

    2012-01-01

    In this paper we demonstrate how Compressive Sensing (CS) can be used in pulse-Doppler radars to improve the Doppler performance while preserving range resolution. We investigate here two types of stepped frequency waveforms, the coherent frequency bursts and successive frequency ramps, which can be

  13. Comparison between Doppler Ultrasound and Biopsy Findings in ...

    African Journals Online (AJOL)

    Methods: We retrospectively studied a random sample of 188 kidney transplanted patients who had Doppler-ultrasound examination followed within two weeks by transplant biopsy. We evaluated the specificity and sensitivity of Doppler ultrasound in diagnosing rejection at different RI thresholds, using the reported biopsy ...

  14. In situ estimation of erosion and deposition thresholds by Acoustic Doppler Velocimeter (ADV)

    DEFF Research Database (Denmark)

    Andersen, T.J.; Fredsøe, Jørgen; Pejrup, M.

    2007-01-01

    Field-based estimations of bed shear stress have been made using SonTek/YSI 10 MHz ADVs (Acoustic Doppler Velocimeter) at the Kongsmark mudflat, Danish Wadden Sea, in order to test if it was possible to estimate erosion and deposition thresholds in situ by use of unidirectional tidal and orbital...... (wave) currents. The results were promising and erosion thresholds were in the same range as those observed in EROMES erosion experiments carried out at the same site. Similarly, the short-term erosion rates which could be calculated matched closely those obtained with EROMES, and were in the same range...... as those published for a large annular flume (Sea Carousel) from another fine-grained site. This indicates that the erosion rates obtained with those two erosion-instruments are reasonable estimates of the actual erosion taking place under natural tidal current and waves. One advantage of the use of ADVs...

  15. New phase method of measuring particle size with laser Doppler radar

    Science.gov (United States)

    Zemlianskii, Vladimir M.

    1996-06-01

    A vast field of non-contact metrology, vibrometry, dynamics and microdynamics problems solved on the basis of laser Doppler method resulted in the development of great variety of laser Doppler radar (LDR). In coherent LDR few beams with various polarization are generally adopted, that are directed at the zone of measurement, through which the probing air stream moves. Studies of various coherent LDR demonstrated that polarization-phase effects of scattering can in some cases considerably effect on the signal-to-noise ratio of the Doppler signal. On the other side using phase effects can simultaneous measurement of size and velocity of spherical particles. New possibilities for improving the accuracy of measuring spherical particles' sizes come to light when application is made in coherent LDR of two waves- probing and one out of the types of symmetrical reception of scattered radiation, during which phase-conjugate signals are formed. The theoretical analysis on the basis of the scattering theory showed, that in symmetrical reception of scattered radiation with respect to the planes OXZ and OYZ output signal of the photoreceiver contains two high- frequency signal components, which in relation to parameters of the probing and size, can either be in phase or antiphase. Results of numerical modeling are presented: amplitude of high frequency signal, coefficient of phase and polarization matching of mixed waves, the depths of photocurrent modulation and also signal's phase in relation to the angle between the probing beams. Phase method of determining particle's sizes based on the use of two wavelengths probing and symmetrical reception of scattered radiation in which conditions for the formation of phase conjugated high-frequency signals are satisfied is presented.

  16. Analysis of Doppler effect with JAERI-Fast set

    International Nuclear Information System (INIS)

    Takano, Hideki; Matsui, Yasushi.

    1977-07-01

    Temperature dependence of group cross sections in the JAERI-Fast set versions I, IR, II and IIR has been tested from the analysis of Doppler experiments performed with two different methods. One is Doppler reactivity measurement for the whole core of SEFOR assembly, and the other sample Doppler reactivity measurement for natural UO 2 in FCA assemblies V-1, V-2, VI-1 and VI-2, ZPR-6-7, ZPR-3-47, and ZPPR-2 and 3. Doppler effects were calculated with one- and two-dimensional diffusion 1-st order perturbation code DOPP2D. The results calculated with the JAERI-Fast set versions II and IIR are in good agreement with the experimental ones. In these calculation, resonance heterogeneity effect, stainless-stell buffer effect and plate heterogeneity effect are considered, and these effects contribute significantly to Doppler effect. (auth.)

  17. Shock wave treatment in medicine

    Indian Academy of Sciences (India)

    Home; Journals; Journal of Biosciences; Volume 30; Issue 2 ... In the present paper we discuss the basic theory and application of shock waves and its history in medicine. The idea behind using shock wave therapy for orthopedic diseases is the stimulation of healing in tendons, surrounding tissue and bones. This is a ...

  18. Pulsatile blood flow in human bone assessed by laser-Doppler flowmetry and the interpretation of photoplethysmographic signals

    International Nuclear Information System (INIS)

    Binzoni, Tiziano; Tchernin, David; Hyacinthe, Jean-Noël; Van De Ville, Dimitri; Richiardi, Jonas

    2013-01-01

    Human bone blood flow, mean blood speed and the number of moving red blood cells were assessed (in arbitrary units), as a function of time, during one cardiac cycle. The measurements were obtained non-invasively on five volunteers by laser-Doppler flowmetry at large interoptode spacing. The investigated bones included: patella, clavicle, tibial diaphysis and tibial malleolus. As hypothesized, we found that in all bones the number of moving cells remains constant during cardiac cycles. Therefore, we concluded that the pulsatile nature of blood flow must be completely determined by the mean blood speed and not by changes in blood volume (vessels dilation). Based on these results, it is finally demonstrated using a mathematical model (derived from the radiative transport theory) that photoplethysmographic (PPG) pulsations observed by others in the literature, cannot be generated by oscillations in blood oxygen saturation, which is physiologically linked to blood speed. In fact, possible oxygen saturation changes during pulsations decrease the amplitude of PPG pulsations due to specific features of the PPG light source. It is shown that a variation in blood oxygen saturation of 3% may induce a negative change of ∼1% in the PPG signal. It is concluded that PPG pulsations are determined by periodic ‘positive’ changes of the reduced scattering coefficient of the tissue and/or the absorption coefficient at constant blood volume. No explicit experimental PPG measurements have been performed. As a by-product of this study, an estimation of the arterial pulse wave velocity obtained from the analysis of the blood flow pulsations give a value of 7.8 m s −1 (95% confidence interval of the sample mean distribution: [6.7, 9.5] m s −1 ), which is perfectly compatible with data in the literature. We hope that this note will contribute to a better understanding of PPG signals and to further develop the domain of the vascular physiology of human bone. (note)

  19. Laser Doppler flowmetry evaluation of gingival recovery response after laser treatment

    Science.gov (United States)

    Todea, Carmen; Cânjǎu, Silvana; Dodenciu, Dorin; Miron, Mariana I.; Tudor, Anca; Bǎlǎbuc, Cosmin

    2013-06-01

    This study was performed in order to evaluate in vivo the applicability of Laser Doppler Flowmetry (LDF) in recording the gingival blood flow and to assess the changes of gingival blood flow following gingival reshaping performed with Er:YAG and 980 nm diode lasers. The LDF evaluation was performed on 20 anterior teeth, which underwent reshaping of gingiva, corresponding to 5 female patients (4 anterior teeth/patient), aged between 20 and 35. One part of the mouth was treated with Er:YAG laser (LP, VLP modes, 140 - 250 mJ, 10 - 20 Hz, using cylindrical sapphire tips) and other part with 980 nm diode laser (CW, 4 W, contact mode and saline solution cooling). The gingival blood flow was monitored using a MoorLab laser Doppler equipment (Moor Instruments Ltd., Axminster, UK) with a straight optical probe, MP3b, 10 mm. The data were processed using statistical analysis software SPSS v16.0.1. The investigation showed an evident decrease in perfusion for both areas in comparison with the baseline values 24 hours after treatment. The microvascular blood flow increased significantly after 7 days in both areas but mostly in diode area (pdiode area remained at a high level after 14 days. Both lasers proved efficiency in the surgical treatment of gingival tissue. Moreover, Laser Doppler Flowmetry is adequate for recording changes in gingival blood flow following periodontal surgery.

  20. Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models

    Directory of Open Access Journals (Sweden)

    Anderson Chun On Tsang

    2015-04-01

    Full Text Available Purpose: The aim of this study was to validate a computational fluid dynamics (CFD simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods: Computational and physical models of patient-specific bifurcation and sidewall aneurysms were constructed from computed tomography angiography with use of stereolithography, a three-dimensional printing technology. Flow dynamics parameters before and after flow-diverter treatment were measured with pulse-wave and color Doppler ultrasonography, and then compared with CFD simulations. Results: CFD simulations showed drastic flow reduction after flow-diverter treatment in both aneurysms. The mean volume flow rate decreased by 90% and 85% for the bifurcation aneurysm and the side-wall aneurysm, respectively. Velocity contour plots from computer simulations before and after flow diversion closely resembled the patterns obtained by color Doppler ultrasonography. Conclusion: The CFD estimation of flow reduction in aneurysms treated with a flow-diverting stent was verified by Doppler ultrasonography in patient-specific phantom models of bifurcation and side-wall aneurysms. The combination of CFD and ultrasonography may constitute a feasible and reliable technique in studying the treatment of intracranial aneurysms with flow-diverting stents.

  1. The Coincident Coherence of Extreme Doppler Velocity Events with p-mode Patches in the Solar Photosphere.

    Science.gov (United States)

    McClure, Rachel Lee

    2018-06-01

    Observations of the solar photosphere show many spatially compact Doppler velocity events with short life spans and extreme values. In the IMaX spectropolarimetric inversion data of the first flight of the SUNRISE balloon in 2009 these striking flashes in the intergranule lanes and complementary outstanding values in the centers of granules have line of sight Doppler velocity values in excess of 4 sigma from the mean. We conclude that values outside 4 sigma are a result from the superposition of the granulation flows and the p-modes.To determine how granulation and p-modes contribute to these outstanding Doppler events, I separate the two components using the Fast Fourier Transform. I produce the power spectrum of the spatial wave frequencies and their corresponding frequency in time for each image, and create a k-omega filter to separate the two components. Using the filtered data, test the hypothesis that extreme events occur because of strict superposition between the p-mode Doppler velocities and the granular velocities. I compare event counts from the observational data to those produced by random superposition of the two flow components and find that the observational event counts are consistent with the model event counts in the limit of small number statistics. Poisson count probabilities of event numbers observed are consistent with expected model count probability distributions.

  2. Turbulent Structure Under Short Fetch Wind Waves

    Science.gov (United States)

    2015-12-01

    maximum 200 words ) Momentum transfer from wind forcing into the ocean is complicated by the presence of surface waves. Wind momentum and energy are...1,520 m from the mouth of the river to the deployment site ). Map created in Google Earth, October 12, 2015, http://www.google.com/earth/. 33...Doppler processing electronics for each transducer uses 14 bit analog to digital converter to digitize the 1.2 MHz acoustic frequency from the four

  3. High-Frame-Rate Power Doppler Ultrasound Is More Sensitive than Conventional Power Doppler in Detecting Rheumatic Vascularisation

    NARCIS (Netherlands)

    M. van der Ven (Myrthe); J.J. Luime (Jolanda); van der Velden, L.L. (Levinia L.); J.G. Bosch (Hans); J.M.W. Hazes (Mieke); H.J. Vos (Rik)

    2016-01-01

    textabstractEarly recognition of joint inflammation will increase treatment efficacy in rheumatoid arthritis (RA). Yet, conventional power Doppler (PD) ultrasound might not be sufficiently sensitive to detect minor inflammation. We investigated the sensitivity of high-frame rate Doppler, combined

  4. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  5. Doppler time-of-flight imaging

    KAUST Repository

    Heidrich, Wolfgang

    2017-02-16

    Systems and methods for imaging object velocity are provided. In an embodiment, at least one Time-of-Flight camera is used to capture a signal representative of an object in motion over an exposure time. Illumination and modulation frequency of the captured motion are coded within the exposure time. A change of illumination frequency is mapped to measured pixel intensities of the captured motion within the exposure time, and information about a Doppler shift in the illumination frequency is extracted to obtain a measurement of instantaneous per pixel velocity of the object in motion. The radial velocity information of the object in motion can be simultaneously captured for each pixel captured within the exposure time. In one or more aspects, the illumination frequency can be coded orthogonal to the modulation frequency of the captured motion. The change of illumination frequency can correspond to radial object velocity.

  6. Gamma-ray induced doppler broadening

    International Nuclear Information System (INIS)

    Robinson, S.J.

    1992-01-01

    The ultra high resolving power of the GAMS4 double-flat crystal spectrometer (M.S. Dewey et al Nucl. Instrum. Methods A 284 (1989) 151.) has been used to observe the Doppler broadening of gamma-rays emitted by nuclei recoiling at speeds as low as 10 -6 c. Such recoils may be induced by the previous emission of gamma-radiation following thermal neutron capture. If the population mechanism of an excited state is known (or can be approximated) and the slowing down mechanism can be modeled, then this technique can be used to extract the lifetime of excited nuclear states. The combination of this technique and the neutron capture reaction allows the study of states which cannot necessarily be accessed by other means. This has allowed the resolution of a number of long standing questions in low-spin nuclear structure. The basis of the technique is discussed and a number of examples given

  7. Doppler interpretation of quasar red shifts.

    Science.gov (United States)

    Zapolsky, H S

    1966-08-05

    The hypothesis that the quasistellar sources (quasars) are local objects moving with velocities close to the speed of light is examined. Provided there is no observational cutoff on apparent bolometric magnitude for the quasars, the transverse Doppler effect leads to the expectation of fewer blue shifts than red shifts for an isotropic distribution of velocities. Such a distribution also yields a function N(z), the number of objects with red shift less than z which is not inconsistent with the present data. On the basis of two extreme assumptions concerning the origin of such rapidly moving sources, we computed curves of red shift plotted against magnitude. In particular, the curve obtained on the assumption that the quasars originated from an explosion in or nearby our own galaxy is in as good agreement with the observations as the curve of cosmological red shift plotted against magnitude.

  8. Microscale Heat Conduction Models and Doppler Feedback

    International Nuclear Information System (INIS)

    Hawari, Ayman I.; Ougouag, Abderrafi

    2015-01-01

    The objective of this project is to establish an approach for providing the fundamental input that is needed to estimate the magnitude and time-dependence of the Doppler feedback mechanism in Very High Temperature reactors. This mechanism is the foremost contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic (TRISO) coated particles. Therefore, its correct prediction is essential to the conduct of safety analyses for these reactors. Since the effect is directly dependent on the actual temperature reached by the fuel during transients, the underlying phenomena of heat deposition, heat transfer and temperature rise must be correctly predicted. To achieve the above objective, this project will explore an approach that accounts for lattice effects as well as local temperature variations and the correct definition of temperature and related local effects.

  9. Spin-wave propagation and spin-polarized electron transport in single-crystal iron films

    Science.gov (United States)

    Gladii, O.; Halley, D.; Henry, Y.; Bailleul, M.

    2017-11-01

    The techniques of propagating spin-wave spectroscopy and current-induced spin-wave Doppler shift are applied to a 20-nm-thick Fe/MgO(001) film. The magnetic parameters extracted from the position of the spin-wave resonance peaks are very close to those tabulated for bulk iron. From the zero-current propagating wave forms, a group velocity of 4 km/s and an attenuation length of about 6 μ m are extracted for 1.6-μ m -wavelength spin wave at 18 GHz. From the measured current-induced spin-wave Doppler shift, we extract a surprisingly high degree of spin polarization of the current of 83 % , which constitutes the main finding of this work. This set of results makes single-crystalline iron a promising candidate for building devices utilizing high-frequency spin waves and spin-polarized currents.

  10. Ultrasonic intrusion sensor using the Doppler effect; Choonpa Doppler hoshiki shinnyu sensor

    Energy Technology Data Exchange (ETDEWEB)

    Kani, H; Iwasaki, N; Goto, M [Nippon Soken, Inc., Tokyo (Japan); Tsuzuki, T; Nakamura, T [Denso Corp., Aichi (Japan)

    1997-10-01

    For vehicle anti-theft alarm systems which cope with vehicle and car component theft, EU initiated vehicle security regulations from Jan 1997. Also, the insurance industry has instituted the insurance certification of vehicle anti-theft alarm systems. We have developed an ultrasonic intrusion sensor using the doppler effect for vehicle anti-theft alarm systems specifically for these EU regulations and insurance certification. 2 refs., 7 figs., 1 tab.

  11. Laser Doppler imaging as a tool in the burn wound treatment protocol

    OpenAIRE

    Venclauskiene, Algirda; Basevicius, Algidas; Zacharevskij, Ernest; Vaicekauskas, Vytautas; Rimdeika, Rytis; Lukosevicius, Saulius

    2014-01-01

    Introduction The main treatment of burns is early excision of injured tissues. Aim To compare two different methods of examination of burned patients: clinical burn depth examination (CDE) and laser Doppler imaging (LDI). Material and methods A prospective randomized study of 57 burn patients treated in 2009–2011 was carried out. The burned patients were randomized into a CDE group and an LDI group. The CDE and LDI scan were performed 72 h after injury, with the second and third CDE and LDI s...

  12. In-vivo imaging of blood flow dynamics using color Doppler optical coherence tomography

    Science.gov (United States)

    Yazdanfar, Siavash; Rollins, Andrew M.; Izatt, Joseph A.

    2000-04-01

    Noninvasive quantitation of blood flow in the retinal micro circulation may elucidate the progression and treatment of ocular disorders including diabetic retinopathy, age-related degeneration, and glaucoma. Color Doppler optical coherence tomography was recently introduced as a technique allowing simultaneous micron-scale resolution cross-sectional imaging of tissue micro structure and blood flow in the human retina. Here, time-resolved imaging of dynamics of blood flow profiles was performed to measure cardiac pulsatility within retinal vessels. Retinal pulsatility has been shown to decrease throughout the progression of diabetic retinopathy.

  13. Role of color Doppler in differentiation of Graves' disease and thyroiditis in thyrotoxicosis

    Science.gov (United States)

    Donkol, Ragab Hani; Nada, Aml Mohamed; Boughattas, Sami

    2013-01-01

    AIM: To evaluate the role of thyroid blood flow assessment by color-flow Doppler ultrasonography in the differential diagnosis of thyrotoxicosis and compare it to technetium pertechnetate thyroid scanning. METHODS: Twenty-six patients with thyrotoxicosis were included in the study. Clinical history was taken and physical examination and thyroid function tests were performed for all patients. Thyroid autoantibodies were measured. The thyroid glands of all patients were evaluated by gray scale ultrasonography for size, shape and echotexture. Color-flow Doppler ultrasonography of the thyroid tissue was performed and spectral flow analysis of both inferior thyroid arteries was assessed. Technetium99 pertechnetate scanning of the thyroid gland was done for all patients. According to thyroid scintigraphy, the patients were divided into two groups: 18 cases with Graves’ disease and 8 cases with Hashimoto’s thyroiditis. All patients had suppressed thyrotropin. The diagnosis of Graves’ disease and Hashimoto’s thyroiditis was supported by the clinical picture and follow up of patients. RESULTS: Peak systolic velocities of the inferior thyroid arteries were significantly higher in patients with Graves’ disease than in patients with thyroiditis (P = 0.004 in the right inferior thyroid artery and P = 0.001 in left inferior thyroid artery). Color-flow Doppler ultrasonography parameters demonstrated a sensitivity of 88.9% and a specificity of 87.5% in the differential diagnosis of thyrotoxicosis. CONCLUSION: Color Doppler flow of the inferior thyroid artery can be used in the differential diagnosis of thyrotoxicosis, especially when there is a contraindication of thyroid scintigraphy by radioactive material in some patients. PMID:23671754

  14. Joint pain and Doppler-detectable bubbles in altitude (Hypobaric) decompression

    Science.gov (United States)

    Powell, Michael R.

    1993-01-01

    The observation that altitude decompression sickness (DCS) is associated with pain in the lower extremities is not new, although it is not a consistent finding. DCS in divers is generally in the upper body, an effect often attributed to non-loading of the body while immersed. In caisson workers, DCS is reported more in the lower extremities. Surprisingly, many researchers do not mention the location of DCS joint pain, apparently considering it to be random. This is not the case for the tissue ratios encountered in studying decompression associated with simulated EVA. In NASA/JSC tests, altitude DCS generally presented first in either the ankle, knee, or hip (83 percent = 73/88). There was a definite statistical relation between the maximum Spencer precordial Doppler Grade and the incidence of DCS in the extremity, although this is not meant to imply a casual relation between circulating gas bubbles and joint pain. The risk of DCS with Grade 4 was considerably higher than that of Grades 0 to 3. The DCS risk was independent of the 'tissue ratio.' There was a predominance of lower extremity DCS even when exercise was performed with the upper body. The reason for these locations we hypothesize to be attributed to the formation of tissue gas micronuclei from kinetic and tensile forces (stress-assisted nucleation) and are the result of the individuals ambulating in a 1g environment. Additionally, since these showers of Doppler bubbles can persist for hours, it is difficult to imagine that they are emanating solely from tendons and ligaments, the supposed site of joint pain. This follows from Henry's law linking the volume of joint tissue (the solvent) and the solubility coefficient of inert gas; there is volumetrically insufficient connective tissue to produce the prolonged release of gas bubbles. If gas bubbles are spawned and released from connective tissue, their volume is increased by those from muscle tissue. Therefore, the nexus between Doppler-detectable gas

  15. Radar observations of ion cyclotron waves associated with two barium shaped-charge releases

    International Nuclear Information System (INIS)

    Providakes, J.; Swartz, W.E.; Kelley, M.C.; Djuth, F.T.; Noble, S.; Jost, R.J.

    1990-01-01

    A 50-MHz Doppler radar interferometer and a 138-MHz Doppler radar were operated from Kennedy Space Center to study 3-m and 1-m plasma waves associated with two shaped-charged barium releases from Wallops Island, Virginia, on May 13, 1986. During the first release, interferometer and Doppler power spectral studies showed the existence of short-lived ( + EIC waves were unstable for field-aligned electron drifts greater than 0.7υ the at the altitude of 510 km in a multispecies (O + , NO + , or similarly O 2 + ) ionospheric plasma. The authors interpret the 30-Hz waves seen by the two radars far above the release as strong electrostatic ion cyclotron waves generated by intense field-aligned currents associated with the barium stream acting like an MHD generator coupled to the ionospheres

  16. Assessment of atrial electromechanical interval and P wave dispersion in patients with polycystic ovary syndrome.

    Science.gov (United States)

    Bayır, Pınar Türker; Güray, Ümit; Duyuler, Serkan; Demirkan, Burcu; Kayaalp, Oya; Kanat, Selçuk; Güray, Yeşim

    2016-02-01

    Polycystic ovary syndrome (PCOS) is associated with increased cardiovascular risk, including ischemic stroke. Prolonged atrial electromechanical interval (EMI) is related to increased atrial fibrillation (AF) risk. The aim of the study is to evaluate atrial EMI and electrocardiographic P-wave indices related to increased AF risk in patients with PCOS. Forty PCOS patients diagnosed on the basis of the Rotterdam criteria and 20 age-matched controls were prospectively included. patients with atrioventricular or intraventricular conduction abnormalities, dysrhythmia or taking antiarrhythmic drugs, atherosclerotic heart disease, cardiomyopathies, valvular lesions, pericardial disease, a history of pulmonary emboli or pulmonary hypertension, and abnormal thyroid function were excluded. Intra and interatrial EMI were measured by tissue Doppler imaging and P-wave dispersion (Pd) was calculated on 12-lead electrocardiography (ECG). The Isovolumetric relaxation time was the interval between the aortic valve closure artifact at the end of the LV outflow envelope and the mitral valve opening artifact at the beginning of the mitral E wave. Patients with PCOS had significantly higher interatrial [38 (24-65) ms vs. 16 (9-19) ms pPCOS group compared with control group [45 (27-60) ms vs. 30 (26-38) ms, pPCOS. PCOS is associated with prolonged inter- and intra-atrial conduction times, which are related to increased AF risk.

  17. Highly Nonlinear Wave Propagation in Elastic Woodpile Periodic Structures

    Science.gov (United States)

    2016-08-03

    called a nanopteron, is not only motivated theoretically and numerically, but are also visualized experimentally by means of a laser Doppler vibrometer...velocity, which clearly follow the prin- cipal solitary wave (highlighted in red color ). It should be noted that the velocities involved in the

  18. Field verification of ADCP surface gravity wave elevation spectra

    NARCIS (Netherlands)

    Hoitink, A.J.F.; Peters, H.C.; Schroevers, M.

    2007-01-01

    Acoustic Doppler current profilers (ADCPs) can measure orbital velocities induced by surface gravity waves, yet the ADCP estimates of these velocities are subject to a relatively high noise level. The present paper introduces a linear filtration technique to significantly reduce the influence of

  19. Use of Doppler ultrasound for non-invasive urodynamic diagnosis

    Directory of Open Access Journals (Sweden)

    Hideo Ozawa

    2009-01-01

    Full Text Available Objectives: A totally non-invasive transperineal urodynamic technique using Doppler ultrasonography has been developed. Methods: Since normal urine does not have blood cells, urine was thought not to produce the Doppler effects. However, basic studies confirmed that the decrease of pressure at high velocity (Bernouilli effect caused dissolved gas to form microbubbles, which are detected by Doppler ultrasonography. Subjects sat and the probe was advanced via remote control to achieve gentle contact with the perineal skin. The digital uroflow data signals and the color Doppler ultrasound video images were processed on a personal computer. The flow-velocity curves from two sites; the distal prostatic urethra just above the external sphincter (V1 and the sphincteric urethra (V2 were plotted against time. The parameters of both the pressure-flow studies and the Doppler ultrasound urodynamic studies were compared in men who had various degrees of obstruction. Results: Functional cross-sectional area at prostatic urethra (A1, calculated by Q max /V1, was lower in the group of bladder outlet obstruction (BOO vs. control group. Velocity ratio (VR, which was calculated by V1/V2, was the parameter having the best correlation with BOO index, though A1 had a similar correlation. This method is viable to diagnose the degree of BOO. Conclusions: The development of non-invasive Doppler ultrasound videourodynamics (Doppler UDS will dramatically expand the information on voiding function.

  20. Acoustic Doppler Current Profiler Data Processing System manual [ADCP

    Science.gov (United States)

    Cote, Jessica M.; Hotchkiss, Frances S.; Martini, Marinna A.; Denham, Charles R.; revisions by Ramsey, Andree L.; Ruane, Stephen

    2000-01-01

    This open-file report describes the data processing software currently in use by the U.S. Geological Survey (USGS), Woods Hole Coastal and Marine Science Center (WHCMSC), to process time series of acoustic Doppler current data obtained by Teledyne RD Instruments Workhorse model ADCPs. The Sediment Transport Instrumentation Group (STG) at the WHCMSC has a long-standing commitment to providing scientists high quality oceanographic data published in a timely manner. To meet this commitment, STG has created this software to aid personnel in processing and reviewing data as well as evaluating hardware for signs of instrument malfunction. The output data format for the data is network Common Data Form (netCDF), which meets USGS publication standards. Typically, ADCP data are recorded in beam coordinates. This conforms to the USGS philosophy to post-process rather than internally process data. By preserving the original data quality indicators as well as the initial data set, data can be evaluated and reprocessed for different types of analyses. Beam coordinate data are desirable for internal and surface wave experiments, for example. All the code in this software package is intended to run using the MATLAB program available from The Mathworks, Inc. As such, it is platform independent and can be adapted by the USGS and others for specialized experiments with non-standard requirements. The software is continuously being updated and revised as improvements are required. The most recent revision may be downloaded from: http://woodshole.er.usgs.gov/operations/stg/Pubs/ADCPtools/adcp_index.htm The USGS makes this software available at the user?s discretion and responsibility.