WorldWideScience

Sample records for wave doppler echocardiography

  1. Color M-mode and pulsed wave tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To assess the association between color M-mode flow propagation velocity and the early diastolic mitral annular velocity (E(m)) obtained with tissue Doppler echocardiography and to assess the prognostic implications of the indexes, echocardiography was performed on days 1 and 5, and 1 and 3 month...

  2. Doppler echocardiography in pediatric cardiology

    International Nuclear Information System (INIS)

    Allen, H.D.; Marx, G.R.

    1986-01-01

    Congenital heart disease encompasses abnormalities in cardiac development which generally have in common either valve stenoses or connections between chambers or great vessels. Usually, abnormalities of intracardiac anatomy, and often, abnormalities of great vessel anatomy, can be unraveled by two-dimensional echocardiography. However, echocardiography offers little information regarding flow characteristics in the various congenital lesions. Addition of the Doppler principle, particularly when combined with the two-dimensional examination, can characterize the source of a flow disturbance, quantify gradients across a site of obstruction, and quantify flow volume across sites where flow is nonturbulent. These features make Doppler echocardiography unique for noninvasive accurate evaluation of children and adults with various forms of congenital heart disease. In this report, the authors discuss some of the present uses of Doppler echocardiography in congenital heart disease. Application of this technique requires greater understanding of certain physics principles than does routine echocardiography

  3. Recommendations for terminology and display for doppler echocardiography

    International Nuclear Information System (INIS)

    Anon.

    1986-01-01

    Doppler echocardiography has recently emerged as a major noninvasive technique with many applications in cardiology. To a large extent, this has been based upon a combination of clinical and engineering advances which now make possible the use of quantitative Doppler echocardiography in combination with two-dimensional imaging for measurement of volume flows, transvalve gradients, and other physiologic flow parameters which reflect cardiac function. It was the purpose of this Committee to provide a glossary of terms which could be used in standard fashion for papers and discussions related to Doppler echocardiography. As part of its task, the Committee also undertook an attempt to recommend a standard for display of Doppler information which would be useful, both for manufacturers and for clinicians. The document, therefore, includes: Section I, the Committee's recommendations for Doppler display. Section II, the glossary of Doppler terms, related to engineering and to clinical applications

  4. Pulsed-wave tissue Doppler and color tissue Doppler echocardiography: calibration with M-mode, agreement, and reproducibility in a clinical setting

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; Jons, Christian; Fritz-Hansen, Thomas

    2009-01-01

    BACKGROUND: Myocardial velocities can be measured with both pulsed-wave tissue Doppler (PWTD) and color tissue Doppler (CTD) echocardiography. We aimed to (A) to explore which of the two methods better approximates true tissue motion and (B) to examine the agreement and the reproducibility...... of the two methods in a routine clinical setting. METHODS: For Study A, the displacements of 63 basal myocardial segments from 13 patients were examined with M-mode and compared with the velocity-time integral of PWTD and CTD velocities. For Study B, the basal lateral segments from 58 patients were examined...... with PWTD and CTD, and the peak myocardial velocities during systole (Sm), early diastole (Em), and late diastole (Am) were measured. RESULTS: Study A: CTD-based measurements of displacement were 12% lower than M-mode measurements (95% CI: -18%; -6%). PWTD velocity-time integrals measured at the outer edge...

  5. Ratio of left ventricular peak E-wave velocity to flow propagation velocity assessed by color M-mode Doppler echocardiography in first myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Seward, J B

    2000-01-01

    OBJECTIVES: To determine the ability of the ratio of peak E-wave velocity to flow propagation velocity (E/Vp) measured with color M-mode Doppler echocardiography to predict in-hospital heart failure and cardiac mortality in an unselected consecutive population with first myocardial infarction (MI...

  6. Temporal enhancement of two-dimensional color doppler echocardiography

    Science.gov (United States)

    Terentjev, Alexey B.; Settlemier, Scott H.; Perrin, Douglas P.; del Nido, Pedro J.; Shturts, Igor V.; Vasilyev, Nikolay V.

    2016-03-01

    Two-dimensional color Doppler echocardiography is widely used for assessing blood flow inside the heart and blood vessels. Currently, frame acquisition time for this method varies from tens to hundreds of milliseconds, depending on Doppler sector parameters. This leads to low frame rates of resulting video sequences equal to tens of Hz, which is insufficient for some diagnostic purposes, especially in pediatrics. In this paper, we present a new approach for reconstruction of 2D color Doppler cardiac images, which results in the frame rate being increased to hundreds of Hz. This approach relies on a modified method of frame reordering originally applied to real-time 3D echocardiography. There are no previous publications describing application of this method to 2D Color Doppler data. The approach has been tested on several in-vivo cardiac 2D color Doppler datasets with approximate duration of 30 sec and native frame rate of 15 Hz. The resulting image sequences had equivalent frame rates to 500Hz.

  7. Transthoracic Doppler echocardiography – noninvasive diagnostic window for coronary flow reserve assessment

    Directory of Open Access Journals (Sweden)

    Dimitrow Paweł

    2003-04-01

    Full Text Available Abstract This review focuses on transthoracic Doppler echocardiography as noninvasive method used to assess coronary flow reserve (CFR in a wide spectrum of clinical settings. Transthoracic Doppler echocardiography is rapidly gaining appreciation as popular tool to measure CFR both in stenosed and normal epicardial coronary arteries (predominantly in left anterior descending coronary artery. Post-stenotic CFR measurement is helpful in: functional assessment of moderate stenosis, detection of significant or critical stenosis, monitoring of restenosis after revascularization. In the absence of stenosis in the epicardial coronary artery, decreased CFR enable to detect impaired microvascular vasodilatation in: reperfused myocardial infarct, arterial hypertension with or without left ventricular hypertrophy, diabetes mellitus, hypercholesterolemia, syndrome X, hypertrophic cardiomyopathy. In these diseases, noninvasive transthoracic Doppler echocardiography allows for serial CFR evaluations to explore the effect of various pharmacological therapies.

  8. Tissue Doppler echocardiography – A case of right tool, wrong use

    Directory of Open Access Journals (Sweden)

    Thomas George

    2004-08-01

    Full Text Available Abstract Background The developments in echocardiography or ultrasound cardiography (UCG have improved our clinical capabilities. However, advanced hardware and software capabilities have resulted in UCG facilities of dubious clinical benefits. Is tissue Doppler echocardiography (TDE is one such example? Presentation of the hypothesis TDE has been touted as advancement in the field of echocardiography. The striking play of colors, impressive waveforms and the seemingly accurate velocity values could be deceptive. TDE is a clear case of inappropriate use of technology. Testing the hypothesis To understand this, a comparison between flow Doppler and tissue Doppler is made. To make clinically meaningful velocity measurements with Doppler, we need prior knowledge of the line of motion. This is possible in blood flow but impossible in the complex myocardial motion. The qualitative comparison makes it evident that Doppler is best suited for flow studies. Implications of the hypothesis As of now TDE is going backwards using an indirect method when direct methods are better. The work on TDE at present is only debatable 'research and publication' material and do not translate into tangible clinical benefits. There are several advances like curved M-mode, strain rate imaging and tissue tracking in TDE. However these have been disappointing. This is due to the basic flaw in the application of the principles of Doppler. Doppler is best suited for flow studies and applying it to tissue motion is illogical. All data obtained by TDE is scientifically incorrect. This makes all the published papers on the subject flawed. Making diagnostic decisions based on this faulty application of technology would be unacceptable to the scientific cardiologist.

  9. Assessment of right ventricular systolic function by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjærgaard, Jesper

    2012-01-01

    This thesis summarizes a series of studies performed in order to assess the clinical usefulness of a novel echocardiographic technology that allows non-invasive assessment of regional right ventricular myocardial velocities and deformation: tissue Doppler echocardiography. While the technology...... is a promising tool for improving our understanding of right ventricular hemodynamics, several aspects of the technology must be evaluated. The accuracy and reproducibility of the technology is evaluated in vitro, and normal values, impact of changes in loading of the right ventricle, response to exercise...... on right ventricular hemodynamics: pulmonary embolism, Arrhythmogenic right ventricular cardiomyopathy and pulmonary regurgitation, the latter in an animal model. The conclusions of the thesis are: Color tissue Doppler echocardiography accurately measures velocities, SR and strain in vitro. No systematic...

  10. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    OpenAIRE

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 ...

  11. Evaluation of regional wall motion abnormalities of the heart. Comparison with Doppler tissue echocardiography, MR-tagging and levocardiography

    International Nuclear Information System (INIS)

    Kivelitz, D.E.; Enzweiler, C.N.H.; Hamm, B.; Borges, A.C.; Walde, T.; Rutsch, W.; Baumann, G.

    2004-01-01

    Purpose: To compare the visual analysis of magnetic resonance imaging (MRI) with the tagging technique and Doppler tissue echocardiography with invasive ventriculography in detecting and quantifying regional left ventricular wall motion abnormalities. Materials and Methods: Sixteen patients with coronary artery disease and a history of prior myocardial infarction underwent invasive ventriculography. Doppler tissue echocardiography and MR-tagging within one week. Regional wall motion abnormalities (WMA) were detected in all patients. WMA were graded as normal=1; hypokinetic=2; akinetic=3; or dyskinetic=4. For agreement between MRI, echocardiography, and ventriculography the kappa coefficient (κ) according to Cohen was calculated. Results: The kappa coefficient (κ) was 0.962 for agreement between MRI and echocardiography and 0.602 for agreement between MRI and ventriculography as well as between echocardiography and ventriculography. Conclusion: Reliable analysis of regional left ventricular wall motion abnormalities is feasible using visual analysis of MR-tagging. MRI and Doppler tissue echocardiography detect more WMA than invasive ventriculography and grade them as more severe. (orig.)

  12. Doppler Echocardiography Assessment of Aortic Stiffness in Female Adolescents with Anorexia Nervosa.

    Science.gov (United States)

    Escudero, Carolina A; Potts, James E; Lam, Pei-Yoong; De Souza, Astrid M; Mugford, Gerald J; Sandor, George G S

    2018-03-17

    Anorexia nervosa (AN) is associated with abnormalities in biomarkers of cardiovascular risk. Arterial stiffness, as measured by pulse-wave velocity (PWV), is also a risk factor for cardiovascular disease. The aims of this study were to determine the stiffness of the aorta in female adolescents with AN and to determine if either the severity or the type of AN was associated with PWV. This was a retrospective case-control study. Adolescent patients with a clinical diagnosis of AN were included. Aortic diameter and pulse-wave transit time over a portion of the thoracic aorta were measured using Doppler echocardiography, and PWV was calculated. There were 94 female patients with AN and 60 adolescent female control subjects. There was no significant difference in age between patients with AN and control subjects (15.5 ± 1.7 vs 15.1 ± 2.6 years, P = .220). Body mass index (16.0 ± 2.4 vs 19.7 ± 2.7 kg/m 2 , P study suggests that patients with AN may be at increased risk for future cardiovascular disease. Future studies are required to determine the reversibility of these changes with weight restoration. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  13. Diagnostic value of Doppler echocardiography for identifying hemodynamic significant pulmonary valve regurgitation in tetralogy of Fallot: comparison with cardiac MRI.

    Science.gov (United States)

    Beurskens, Niek E G; Gorter, Thomas M; Pieper, Petronella G; Hoendermis, Elke S; Bartelds, Beatrijs; Ebels, Tjark; Berger, Rolf M F; Willems, Tineke P; van Melle, Joost P

    2017-11-01

    Quantification of pulmonary regurgitation (PR) is essential in the management of patients with repaired tetralogy of Fallot (TOF). We sought to evaluate the accuracy of first-line Doppler echocardiography in comparison with cardiac magnetic resonance imaging (MRI) to identify hemodynamic significant PR. Paired cardiac MRI and echocardiographic studies (n = 97) in patients with repaired TOF were retrospectively analyzed. Pressure half time (PHT) and pulmonary regurgitation index (PRi) were measured using continuous wave Doppler. The ratio of the color flow Doppler regurgitation jet width to pulmonary valve (PV) annulus (jet/annulus ratio) and diastolic to systolic time velocity integral (DSTVI; pulsed wave Doppler) were assessed. Accuracy of echocardiographic measurements was tested to identify significant PR as determined by phase-contrast MRI (PR fraction [PRF] ≥ 20%). Mean PRF was 29.4 ± 15.7%. PHT < 100 ms had a sensitivity of 93%, specificity 75%, positive predictive value (PPV) 92% and negative predictive value (NPV) 78% for identifying significant PR (C-statistic 0.82). PRi < 0.77 had sensitivity and specificity of 66% and 54%, respectively (C-statistic 0.63). Jet/annulus ratio ≥1/3 had sensitivity 96%, specificity 75%, PPV 92% and NPV 82% (C-statistic 0.87). DSTVI had sensitivity 84%, specificity 33%, PPV 84% and NPV 40%, (C-statistic 0.56). Combined jet/annulus ratio ≥1/3 and PHT < 100 ms was highly accurate in identifying PRF ≥ 20%, with sensitivity 97% and specificity 100%. PHT and jet/annulus ratio on Doppler echocardiography, especially when combined, are highly accurate in identifying significant PR and therefore seem useful in the follow-up of patients with repaired TOF.

  14. Tissue doppler echocardiography for evaluating left ventricular functions in obese

    Directory of Open Access Journals (Sweden)

    Mecnun Çetin

    2013-03-01

    Full Text Available Objective: The aim of this study was to investigate theimpact of childhood obesity on ventricular functions usingtissue Doppler echocardiography.Materials and methods: The mitral tissue Doppler signalswere recorded in the apical four-chamber view, with thesample volume placed at the lateral walls of mitral annulus.The mitral flow was examined with the sample Pulse Dopplerpositioned parallely to flow just at the orifice of the mitralleaflets. Twenty obese (mean age, 161.5±25.8 monthsand 20 healthy children (mean age, 151.2±33.5 monthswere included to this study.Results: Body mass index (BMI was significantly higherin obese group (30.92±6.87. Isovolumic relaxation time(IVRT which is one of the left ventricular (LV diastolicfunction parameters was 66.10±7.30 ms in obese group,and 58.70±9.06 ms in the control group. IVRT was significantlyhigher in the obese group (p=0.007. In obesegroup, the mitral annulus tissue Doppler E velocity wasdecreased, flow velocity was increased and decrement inEm/Am ratio was significant. We found significant negativecorrelation between BMI and LV Em/Am ratio. Myocardialperformance index (MPI in obese group and control groupwas 0.50±0.07 and 0.41±0.04, respectively (p<0.001.Between MPI and LV Em/Am ratio there was a significantnegative correlation while MPI showed positive correlationwith BMI. In obese group septal and LV posterior wall thicknesswas shown to be significantly increased compared tothe control group (p<0.001.Conclusion: Our findings, may be important for determinationof the relationship between obesity and cardiovascularrisk factors in children. Tissue Doppler echocardiographicimaging may be useful in revealing this relationship.Key words: obesity, doppler echocardiography, ventricular dysfunction

  15. Transesophageal color Doppler evaluation of obstructive lesions using the new "Quasar" technology.

    Science.gov (United States)

    Fan, P; Nanda, N C; Gatewood, R P; Cape, E G; Yoganathan, A P

    1995-01-01

    Due to the unavoidable problem of aliasing, color flow signals from high blood flow velocities cannot be measured directly by conventional color Doppler. A new technology termed Quantitative Un-Aliased Speed Algorithm Recognition (Quasar) has been developed to overcome this limitation. Employing this technology, we used transesophageal color Doppler echocardiography to investigate whether the velocities detected by the Quasar would correlate with those obtained by continuous-wave Doppler both in vitro and in vivo. In the in vitro study, a 5.0 MHz transesophageal transducer of a Kontron Sigma 44 color Doppler flow system was used. Fourteen different peak velocities calculated and recorded by color Doppler-guided continuous-wave Doppler were randomly selected. In the clinical study, intraoperative transesophageal echocardiography was performed using the same transducer 18 adults (13 aortic valve stenosis, 2 aortic and 2 mitral stenosis, 2 hypertrophic obstructive cardiomyopathy and 1 mitral valve stenosis). Following each continuous-wave Doppler measurement, the Quasar was activated, and a small Quasar marker was placed in the brightest area of the color flow jet to obtain the maximum mean velocity readout. The maximum mean velocities measured by Quasar closely correlated with maximum peak velocities obtained by color flow guided continuous-wave Doppler in both in vitro (0.53 to 1.65 m/s, r = 0.99) and in vivo studies (1.50 to 6.01 m/s, r = 0.97). We conclude that the new Quasar technology can accurately measure high blood flow velocities during transesophageal color Doppler echocardiography. This technique has the potential of obviating the need for continuous-wave Doppler.

  16. Quantitation of stress echocardiography by tissue Doppler and strain rate imaging: a dream come true?

    Science.gov (United States)

    Galderisi, Maurizio; Mele, Donato; Marino, Paolo Nicola

    2005-01-01

    Tissue Doppler (TD) is an ultrasound tool providing a quantitative agreement of left ventricular regional myocardial function in different modalities. Spectral pulsed wave (PW) TD, performed online during the examination, measures instantaneous myocardial velocities. By means of color TD, velocity images are digitally stored for subsequent off-line analysis and mean myocardial velocities are measured. An implementation of color TD includes strain rate imaging (SRI), based on post-processing conversion of regional velocities in local myocardial deformation rate (strain rate) and percent deformation (strain). These three modalities have been applied to stress echocardiography for quantitative evaluation of regional left ventricular function and detection of ischemia and viability. They present advantages and limitations. PWTD does not permit the simultaneous assessment of multiple walls and therefore is not compatible with clinical stress echocardiography while it could be used in a laboratory setting. Color TD provides a spatial map of velocity throughout the myocardium but its results are strongly affected by the frame rate. Both color TD and PWTD are also influenced by overall cardiac motion and tethering from adjacent segments and require reference velocity values for interpretation of regional left ventricular function. High frame rate (i.e. > 150 ms) post-processing-derived SRI can potentially overcome these limitations, since measurements of myocardial deformation have not any significant apex-to-base gradient. Preliminary studies have shown encouraging results about the ability of SRI to detect ischemia and viability, in terms of both strain rate changes and/or evidence of post-systolic thickening. SRI is, however, Doppler-dependent and time-consuming. Further technical refinements are needed to improve its application and introduce new ultrasound modalities to overcome the limitations of the Doppler-derived deformation analysis.

  17. Usefulness of pulse-wave doppler tissue sampling and dobutamine stress echocardiography for identification of false positive inferior wall defects in SPECT

    International Nuclear Information System (INIS)

    Altinmakas, S.; Dagdeviren, B.; Turkmen, M.; Gursurer, M.; Say, B.; Tezel, T.; Ersek, B.

    2000-01-01

    False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58±8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56±7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 μg/kg/min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and/or left circumflex coronary artery (CX) with narrowing (≥50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E/A ratio was lower in patients with CAD when compared to patients without CAD (0.78±0.2 versus 1.29±0.11 p<0.0001). Also the peak stress E/A ratio of normal cases was significantly higher than patients who had CAD (1.19±0.3 versus 0.78±0.2 p<0.0001). When the cut off point for the E/A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E/A were 89% and 86%, respectively. The peak stress E/A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54%±17 versus 99%±24 p=0

  18. Standardised imaging technique for guided M-mode and Doppler echocardiography in the horse.

    Science.gov (United States)

    Long, K J; Bonagura, J D; Darke, P G

    1992-05-01

    Eighteen echocardiographic images useful for diagnostic imaging, M-mode echocardiography, and Doppler echocardiography of the equine heart were standardised by relating the position of the axial beam to various intracardiac landmarks. The transducer orientation required for each image was recorded in 14 adult horses by describing the degree of sector rotation and the orientation of the axial beam relative to the thorax. Repeatable images could be obtained within narrow limits of angulation and rotation for 14 of the 18 standardised images evaluated. Twenty-seven National Hunt horses were subsequently examined using this standardised technique. Selected cardiac dimensions were measured from two-dimensional and guided M-mode studies. Satisfactory results were achieved in 26 of the 27 horses. There was no linear correlation between any of the measured cardiac values and bodyweight. There was no significant difference between measurements taken from the left and the right hemithorax. Six horses were imaged on three consecutive days to assess the repeatability of the measurements. No significant difference was found between measurements obtained on different days. This study demonstrates a method for standardised echocardiographic evaluation of the equine heart that is repeatable, valuable for teaching techniques of equine echocardiography, applicable for diagnostic imaging and quantification of cardiac size, and useful for the evaluation of blood-flow patterns by Doppler ultrasound.

  19. [Pilot study of echocardiographic studies using color- and pulsed-wave spectral Doppler methods in blue-crowned amazons (Amazona ventralis) and blue-fronted amazons (Amazona a. aestiva)].

    Science.gov (United States)

    Pees, M; Straub, J; Schumacher, J; Gompf, R; Krautwald-Junghanns, M E

    2005-02-01

    Colour-flow and pulsed-wave spectral Doppler echocardiography was performed on 6 healthy, adult Hispaniolan amazon parrots (Amazona ventralis) and 6 blue-fronted amazon parrots (Amazona a. aestiva) to establish normal reference values. Birds were anesthetized with isoflurane in oxygen and placed in dorsal recumbency. An electrocardiogram was recorded continuously and birds were imaged with a micro-phased-array scanner with a frequency of 7.0 MHz. After assessment of cardiac function in 2-D-echocardiography, blood flow across the left and the right atrioventricular valve and across the aortic valve was determined using color-flow and pulsed-wave spectral Doppler echocardiography. Diastolic inflow (mean value +/- standard deviation) into the left ventricle was 0.17 +/- 0.02 m/s (Hispaniolan amazons) and 0.18 +/- 0.03 m/s (Blue fronted amazons). Diastolic inflow into the right ventricle was 0.22 +/- 0.05 m/s (Hispaniolan amazons) and 0.22 +/- 0.04 m/s (Blue fronted amazons). Velocity across the aortic valve was 0.84 +/- 0.07 m/s (Hispaniolan amazons) and 0.83 +/- 0.08 m/s (Blue fronted amazons). Systolic pulmonary flow could not be detected in any of the birds in this study. No significant differences were evident between the two species examined. Results of this study indicate that Doppler echocardiography is a promising technique to determine blood flow in the avian heart. Further studies in other avian species are needed to establish reference values for assessment of cardiac function in diseased birds.

  20. Real-time three-dimensional color Doppler echocardiography for characterizing the spatial velocity distribution and quantifying the peak flow rate in the left ventricular outflow tract

    Science.gov (United States)

    Tsujino, H.; Jones, M.; Shiota, T.; Qin, J. X.; Greenberg, N. L.; Cardon, L. A.; Morehead, A. J.; Zetts, A. D.; Travaglini, A.; Bauer, F.; hide

    2001-01-01

    Quantification of flow with pulsed-wave Doppler assumes a "flat" velocity profile in the left ventricular outflow tract (LVOT), which observation refutes. Recent development of real-time, three-dimensional (3-D) color Doppler allows one to obtain an entire cross-sectional velocity distribution of the LVOT, which is not possible using conventional 2-D echo. In an animal experiment, the cross-sectional color Doppler images of the LVOT at peak systole were derived and digitally transferred to a computer to visualize and quantify spatial velocity distributions and peak flow rates. Markedly skewed profiles, with higher velocities toward the septum, were consistently observed. Reference peak flow rates by electromagnetic flow meter correlated well with 3-D peak flow rates (r = 0.94), but with an anticipated underestimation. Real-time 3-D color Doppler echocardiography was capable of determining cross-sectional velocity distributions and peak flow rates, demonstrating the utility of this new method for better understanding and quantifying blood flow phenomena.

  1. New noninvasive diagnosis of myocardial ischemia of the left circumflex coronary artery using coronary flow reserve measurement by transthoracic Doppler echocardiography. Comparison with thallium-201 single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujimoto, Kohei; Watanabe, Hiroyuki; Hozumi, Takeshi; Otsuka, Ryo; Hirata, Kumiko; Yamagishi, Hiroyuki; Yoshiyama, Minoru; Yoshikawa, Junichi

    2004-01-01

    The usefulness of coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography to detect myocardial ischemia was compared with exercise thallium-201 single photon emission computed tomography (SPECT). Transthoracic Doppler echocardiography was performed in 110 patients with suspected coronary artery disease. Color Doppler signals of the left circumflex coronary artery flow in the apical four-chamber view were identified, and the velocities at rest and during hyperemia recorded for calculation of coronary flow reserve by the pulsed Doppler method. All patients underwent SPECT within 1 week of the transthoracic Doppler echocardiographic study. Coronary flow reserve in the left circumflex coronary artery was measured in 79 (72%) of 110 patients. SPECT revealed reversible perfusion defect in the left circumflex coronary artery territories in 12 of 69 patients excluding those with multivessel disease. Coronary flow reserve <2.0 had a sensitivity of 92% and specificity of 96% for reversible perfusion defect detected by SPECT. Noninvasive coronary flow reserve measurement in the left circumflex coronary artery by transthoracic Doppler echocardiography can estimate myocardial ischemia in the left ventricular lateral regions. (author)

  2. Response of a Doppler canceling system to plane gravitational waves

    International Nuclear Information System (INIS)

    Caporali, A.

    1982-01-01

    This paper discusses the interaction of long periodic gravitational waves with a three-link microwave system known as the Doppler canceling system. This system, which was developed for gravitational red-shift experiment, uses one-way and two-way Doppler information to construct the beat signal of two reference oscillators moving with respect to each other. The geometric-optics approximation is used to derive the frequency shift produced on a light signal propagating in a gravitational-wave space-time. The signature left on the Doppler-canceled beat by bursts and continuous gravitational waves is analyzed. A comparison is made between the response to gravitational waves of the Doppler canceling system and that of a (NASA) Doppler tracking system which employs two-way, round-trip radio waves. A threefold repetition of the gravitational wave form is found to be a common feature of the response functions of both systems. These two functions otherwise exhibit interesting differences

  3. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Gang, E-mail: cjr.sungang@vip.163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Min, E-mail: limin22000@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Jiang, Xiang-sen, E-mail: jiangxiangsen123@126.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Li, Li, E-mail: leely1976@yahoo.com.cn [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Peng, Zhao-hui, E-mail: zhaohuipeng_R@163.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China); Mu, Nan-nan, E-mail: munannan22000@sohu.com [Department of Medical Imaging, Jinan Military General Hospital, No. 25, Shifan Road, Jinan, Shandong Province 250031 (China)

    2012-09-15

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality.

  4. Transthoracic Doppler echocardiography to predict optimal tube pulsing window for coronary artery CT angiography

    International Nuclear Information System (INIS)

    Sun, Gang; Li, Min; Jiang, Xiang-sen; Li, Li; Peng, Zhao-hui; Mu, Nan-nan

    2012-01-01

    Rationale and objective: To evaluate the feasibility of transthoracic Doppler echocardiography to determine the optimal pulsing windows for CT coronary angiography to narrow the pulsing windows further, especially in higher heart rate. Materials and methods: Doppler was performed on 135 patients before CT scanning. For Doppler, the intervals with minimal motion were evaluated during both systole and diastole integrating electrocardiogram (ECG) intervals. For CT scanning, the retrospective ECG-gating was applied and the optimal reconstruction intervals were determined. The accuracy of Doppler analysis to predict the optimal reconstruction intervals was tested. The predicted length of pulsing windows was compared between Doppler analysis and traditional prospective ECG-gating protocol (heart rate ≦ 65 bpm, 60–76%; 66–79 bpm, 30–77%; ≧80 bpm, 31–47%). Results: According to Doppler analysis, the mean length of intervals with minimal motion in systole was 106.4 ± 39.2 ms and 125.2 ± 92.0 ms in diastole. When the intervals with minimal motion during diastole > 90 ms, the optimal reconstruction intervals were located at diastole; otherwise, at systole (P < 0.001). The optimal reconstruction intervals in 93.8% (132/135) patients could be predicted accurately by Doppler analysis. If the optimal reconstruction intervals predicted by Doppler were applied as the exposure windows, the mean length of pulsing windows should has been 105.2 ± 69.4 ms (range: 26.9–510.3 ms), which was significantly shorter than that of traditional prospective ECG-gating protocol (232.0 ± 120.2 ms, range: 93.2–427.3 ms, P < 0.001). Conclusion: Doppler can help detecting the optimal pulsing windows accurately. Prospective ECG-gating incorporating Doppler analysis may narrow pulsing windows significantly while maintaining image quality

  5. Doppler evaluation of valvular stenosis

    International Nuclear Information System (INIS)

    Kisslo, J.; Krafchek, J.; Adams, D.; Mark, D.B.

    1986-01-01

    One of the reasons why use of Doppler echocardiography is growing rapidly is because of its utility in detecting the presence of valvular stenosis and in estimating its severity. Detection of the presence of stenotic valvular heart disease using Doppler echocardiography was originally described over 10 years ago. It has been demonstrated that Doppler blood velocity data could be used to estimate the severity of a stenotic lesion. This chapter discusses the evaluation of valvular stenois using Doppler

  6. Two-dimensional intraventricular flow mapping by digital processing conventional color-Doppler echocardiography images.

    Science.gov (United States)

    Garcia, Damien; Del Alamo, Juan C; Tanne, David; Yotti, Raquel; Cortina, Cristina; Bertrand, Eric; Antoranz, José Carlos; Perez-David, Esther; Rieu, Régis; Fernandez-Aviles, Francisco; Bermejo, Javier

    2010-10-01

    Doppler echocardiography remains the most extended clinical modality for the evaluation of left ventricular (LV) function. Current Doppler ultrasound methods, however, are limited to the representation of a single flow velocity component. We thus developed a novel technique to construct 2D time-resolved (2D+t) LV velocity fields from conventional transthoracic clinical acquisitions. Combining color-Doppler velocities with LV wall positions, the cross-beam blood velocities were calculated using the continuity equation under a planar flow assumption. To validate the algorithm, 2D Doppler flow mapping and laser particle image velocimetry (PIV) measurements were carried out in an atrio-ventricular duplicator. Phase-contrast magnetic resonance (MR) acquisitions were used to measure in vivo the error due to the 2D flow assumption and to potential scan-plane misalignment. Finally, the applicability of the Doppler technique was tested in the clinical setting. In vitro experiments demonstrated that the new method yields an accurate quantitative description of the main vortex that forms during the cardiac cycle (mean error for vortex radius, position and circulation). MR image analysis evidenced that the error due to the planar flow assumption is close to 15% and does not preclude the characterization of major vortex properties neither in the normal nor in the dilated LV. These results are yet to be confirmed by a head-to-head clinical validation study. Clinical Doppler studies showed that the method is readily applicable and that a single large anterograde vortex develops in the healthy ventricle while supplementary retrograde swirling structures may appear in the diseased heart. The proposed echocardiographic method based on the continuity equation is fast, clinically-compliant and does not require complex training. This technique will potentially enable investigators to study of additional quantitative aspects of intraventricular flow dynamics in the clinical setting by

  7. Optimal Analysis of Left Atrial Strain by Speckle Tracking Echocardiography: P-wave versus R-wave Trigger.

    Science.gov (United States)

    Hayashi, Shuji; Yamada, Hirotsugu; Bando, Mika; Saijo, Yoshihito; Nishio, Susumu; Hirata, Yukina; Klein, Allan L; Sata, Masataka

    2015-08-01

    Left atrial (LA) strain analysis using speckle tracking echocardiography is useful for assessing LA function. However, there is no established procedure for this method. Most investigators have determined the electrocardiographic R-wave peak as the starting point for LA strain analysis. To test our hypothesis that P-wave onset should be used as the starting point, we measured LA strain using 2 different starting points and compared the strain values with the corresponding LA volume indices obtained by three-dimensional (3D) echocardiography. We enrolled 78 subjects (61 ± 17 years, 25 males) with and without various cardiac diseases in this study and assessed global longitudinal LA strain by two-dimensional speckle tracking strain echocardiography using EchoPac software. We used either R-wave peak or P-wave onset as the starting point for determining LA strains during the reservoir (Rres, Pres), conduit (Rcon, Pcon), and booster pump (Rpump, Ppump) phases. We determined the maximum, minimum, and preatrial contraction LA volumes, and calculated the LA total, passive, and active emptying fractions using 3D echocardiography. The correlation between Pres and LA total emptying fraction was better than the correlation between Rres and LA total emptying fraction (r = 0.458 vs. 0.308, P = 0.026). Pcon and Ppump exhibited better correlation with the corresponding 3D echocardiographic parameters than Rcon (r = 0.560 vs. 0.479, P = 0.133) and Rpump (r = 0.577 vs. 0.345, P = 0.003), respectively. LA strain in any phase should be analyzed using P-wave onset as the starting point rather than R-wave peak. © 2014, Wiley Periodicals, Inc.

  8. Low-Frequency Gravitational Wave Searches Using Spacecraft Doppler Tracking

    Directory of Open Access Journals (Sweden)

    Armstrong J. W.

    2006-01-01

    Full Text Available This paper discusses spacecraft Doppler tracking, the current-generation detector technology used in the low-frequency (~millihertz gravitational wave band. In the Doppler method the earth and a distant spacecraft act as free test masses with a ground-based precision Doppler tracking system continuously monitoring the earth-spacecraft relative dimensionless velocity $2 Delta v/c = Delta u/ u_0$, where $Delta u$ is the Doppler shift and $ u_0$ is the radio link carrier frequency. A gravitational wave having strain amplitude $h$ incident on the earth-spacecraft system causes perturbations of order $h$ in the time series of $Delta u/ u_0$. Unlike other detectors, the ~1-10 AU earth-spacecraft separation makes the detector large compared with millihertz-band gravitational wavelengths, and thus times-of-flight of signals and radio waves through the apparatus are important. A burst signal, for example, is time-resolved into a characteristic signature: three discrete events in the Doppler time series. I discuss here the principles of operation of this detector (emphasizing transfer functions of gravitational wave signals and the principal noises to the Doppler time series, some data analysis techniques, experiments to date, and illustrations of sensitivity and current detector performance. I conclude with a discussion of how gravitational wave sensitivity can be improved in the low-frequency band.

  9. High-frequency dual mode pulsed wave Doppler imaging for monitoring the functional regeneration of adult zebrafish hearts

    Science.gov (United States)

    Kang, Bong Jin; Park, Jinhyoung; Kim, Jieun; Kim, Hyung Ham; Lee, Changyang; Hwang, Jae Youn; Lien, Ching-Ling; Shung, K. Kirk

    2015-01-01

    Adult zebrafish is a well-known small animal model for studying heart regeneration. Although the regeneration of scars made by resecting the ventricular apex has been visualized with histological methods, there is no adequate imaging tool for tracking the functional recovery of the damaged heart. For this reason, high-frequency Doppler echocardiography using dual mode pulsed wave Doppler, which provides both tissue Doppler (TD) and Doppler flow in a same cardiac cycle, is developed with a 30 MHz high-frequency array ultrasound imaging system. Phantom studies show that the Doppler flow mode of the dual mode is capable of measuring the flow velocity from 0.1 to 15 cm s−1 with high accuracy (p-value = 0.974 > 0.05). In the in vivo study of zebrafish, both TD and Doppler flow signals were simultaneously obtained from the zebrafish heart for the first time, and the synchronized valve motions with the blood flow signals were identified. In the longitudinal study on the zebrafish heart regeneration, the parameters for diagnosing the diastolic dysfunction, for example, E/Em < 10, E/A < 0.14 for wild-type zebrafish, were measured, and the type of diastolic dysfunction caused by the amputation was found to be similar to the restrictive filling. The diastolic function was fully recovered within four weeks post-amputation. PMID:25505135

  10. The history of echocardiography.

    Science.gov (United States)

    Edler, Inge; Lindström, Kjell

    2004-12-01

    Following a brief review of the development of medical ultrasonics from the mid-1930s to the mid-1950s, the collaboration between Edler and Hertz that began in Lund in 1953 is described. Using an industrial ultrasonic flaw detector, they obtained time-varying echoes transcutaneously from within the heart. The first clinical applications of M-mode echocardiography were concerned with the assessment of the mitral valve from the shapes of the corresponding waveforms. Subsequently, the various M-mode recordings were related to their anatomical origins. The method then became established as a diagnostic tool and was taken up by investigators outside Lund, initially in China, Germany, Japan and the USA and, subsequently, world-wide. The diffusion of echocardiography into clinical practice depended on the timely commercial availability of suitable equipment. The discovery of contrast echocardiography in the late 1960s further validated the technique and extended the range of applications. Two-dimensional echocardiography was first demonstrated in the late 1950s, with real-time mechanical systems and, in the early 1960s, with intracardiac probes. Transesophageal echocardiography followed, in the late 1960s. Stop-action two-dimensional echocardiography enjoyed a brief vogue in the early 1970s. It was, however, the demonstration by Bom in Rotterdam of real-time two-dimensional echocardiography using a linear transducer array that revolutionized and popularized the subject. Then, the phased array sector scanner, which had been demonstrated in the late 1960s by Somer in Utrecht, was applied to cardiac studies from the mid-1970s onwards. Satomura had demonstrated the use of the ultrasonic Doppler effect to detect tissue motion in Osaka in the mid-1950s and the technique was soon afterwards applied in the heart, often in combination with M-mode recording. The development of the pulsed Doppler method in the late 1960s opened up new opportunities for clinical innovation. The

  11. Color Doppler flow mapping of stenotic and regurgitant natural heart valves

    International Nuclear Information System (INIS)

    Nanda, N.C.

    1986-01-01

    Color Doppler echocardiography has found widest application in reliable detection and assessment of severity of both atrio-ventricular and semi-lunar valve incompetence. The authors believe both the sensitivity and specificity of color Doppler for the detection of mitral and aortic regurgitation is very high in patients with adequate acoustic windows. In 82 patients with proven mitral regurgitation studied, the best correlations with angiography were noted when the maximum or average regurgitant jet are obtained by color Doppler from three standard 2-D echo planes (parasternal long and short axis and apical four chamber view) and expressed as a percentage of the left atrial area were considered. The criteria the authors used for assessment of tricuspid and pulmonary valve incompetence are similar to those used for mitral and aortic valve incompetence, but the lack of a good ''gold'' standard has hampered validation. The color Doppler technique also supplements conventional Doppler in the assessment of severity of stenotic lesions by facilitating parallel alignment of the continuous wave Doppler cursor line with the stenotic jet for accurate recording of maximal velocities and pressure gradients. The authors have found this method especially useful in the assessment of aortic stenosis. In conclusion, color Doppler flow mapping combined with conventional echocardiography provides, for the first time, a comprehensive noninvasive assessement of the severity of regurgitant and stenotic lesions

  12. Cardiovascular assessment of patients with Ullrich-Turner's Syndrome on Doppler echocardiography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Castro Ana Valéria Barros de

    2002-01-01

    Full Text Available OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta. Their ages ranged from 10 to 28 (mean of 16.7 years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%; 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7, mosaics (n=5, and deletions (n=3. No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively. This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.

  13. Assessment of left ventricular regional function in affected and carrier dogs with duchenne muscular dystrophy using speckle tracking echocardiography

    Directory of Open Access Journals (Sweden)

    Yugeta Naoko

    2011-05-01

    Full Text Available Abstract Background Two-dimensional speckle tracking echocardiography (STE is a relatively new method to detect regional myocardial dysfunction. To assess left ventricular (LV regional myocardial dysfunction using STE in Duchenne muscular dystrophy model dogs (CXMDJ without overt clinical signs of heart failure. Methods Six affected dogs, 8 carrier dogs with CXMDJ, and 8 control dogs were used. Conventional echocardiography, systolic and diastolic function by Doppler echocardiography, tissue Doppler imaging (TDI, and strain indices using STE, were assessed and compared among the 3 groups. Results Significant differences were seen in body weight, transmitral E wave and E' wave derived from TDI among the 3 groups. Although no significant difference was observed in any global strain indices, in segmental analysis, the peak radial strain rate during early diastole in posterior segment at chordae the tendineae level showed significant differences among the 3 groups. Conclusions The myocardial strain rate by STE served to detect the impaired cardiac diastolic function in CXMDJ without any obvious LV dilation or clinical signs. The radial strain rate may be a useful parameter to detect early myocardial impairment in CXMDJ.

  14. Application of Echocardiography on Transgenic Mice with Cardiomyopathies

    Directory of Open Access Journals (Sweden)

    G. Chen

    2012-01-01

    Full Text Available Cardiomyopathies are common cardiac disorders that primarily affect cardiac muscle resulting in cardiac dysfunction and heart failure. Transgenic mouse disease models have been developed to investigate the cellular mechanisms underlying heart failure and sudden cardiac death observed in cardiomyopathy cases and to explore the therapeutic outcomes in experimental animals in vivo. Echocardiography is an essential diagnostic tool for accurate and noninvasive assessment of cardiac structure and function in experimental animals. Our laboratory has been among the first to apply high-frequency research echocardiography on transgenic mice with cardiomyopathies. In this work, we have summarized our and other studies on assessment of systolic and diastolic dysfunction using conventional echocardiography, pulsed Doppler, and tissue Doppler imaging in transgenic mice with various cardiomyopathies. Estimation of embryonic mouse hearts has been performed as well using this high-resolution echocardiography. Some technical considerations in mouse echocardiography have also been discussed.

  15. Fetal echocardiography

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/007340.htm Fetal echocardiography To use the sharing features on this page, please enable JavaScript. Fetal echocardiography is a test that uses sound waves ( ultrasound ) ...

  16. Measurement of pulmonary arterial elastance in patients with systolic heart failure using Doppler echocardiography

    Science.gov (United States)

    Taghavi, Sepideh; Esmaeilzadeh, Maryam; Amin, Ahmad; Naderi, Nasim; Abkenar, Hooman Bakhshandeh; Maleki, Majid; Mitra, Chitsazan

    2016-01-01

    Objective: A reliable and easy-to-perform method for measuring right ventricular (RV) afterload is desirable when scheduling patients with systolic heart failure to undergo heart transplantation. The present study aimed to investigate the accuracy of echocardiographically-derived pulmonary arterial elastance as a measurement of pulmonary vascular resistance by comparing it with invasive measures. Methods: Thirty-one patients with moderate to severe systolic heart failure, including 22 (71%) male patients, with a mean age of 41.16±15.9 years were enrolled in the study. Right heart catheterization and comprehensive echocardiography during the first hour after completion of cardiac catheterization were performed in all the patients. The pulmonary artery elastance was estimated using the ratio of end-systolic pressure (Pes) over the stroke volume (SV) by both cardiac catheterization [Ea (PV)-C] and echocardiography [Ea (PV)-E]. Results: The mean Ea (PV)-C and Ea (PV)-E were estimated to be 0.73±0.49 mm Hg/mL and 0.67±0.44 mm Hg/mL, respectively. There was a significant relation between Ea (PV)-E and Ea (PV)-C (r=0.897, pechocardiography and catheterization methods for estimating Ea (PV), investigated by the Bland-Altman method, showed a mean bias of -0.06, with 95% limits of agreement from -0.36 mm Hg/mL to 0.48 mm Hg/mL. Conclusion: Doppler echocardiography is an easy, non-invasive, and inexpensive method for measuring pulmonary arterial elastance, which provides accurate and reliable estimation of RV afterload in patients with systolic heart failure. PMID:26467379

  17. Relevance of tissue Doppler in the quantification of stress echocardiography for the detection of myocardial ischemia in clinical practice

    Directory of Open Access Journals (Sweden)

    Sicari Rosa

    2005-01-01

    Full Text Available Abstract In the present article we review the main published data on the application of Tissue Doppler Imaging (TDI to stress echocardiography for the detection of myocardial ischemia. TDI has been applied to stress echocardiography in order to overcome the limitations of visual analysis for myocardial ischemia. The introduction of a new technology for clinical routine use should pass through the different phases of scientific assessment from feasibility studies to large multicenter studies, from efficacy to effectiveness studies. Nonetheless the pro-technology bias plays a major role in medicine and expensive and sophisticated techniques are accepted before their real usefulness and incremental value to the available ones is assessed. Apparently, TDI is not exempted by this approach : its applications are not substantiated by strong and sound results. Nonetheless, conventional stress echocardiography for myocardial ischemia detection is heavily criticized on the basis of its subjectivity. Stress echocardiography has a long lasting history and the evidence collected over 20 years positioned it as an established tool for the detection and prognostication of coronary artery disease. The quantitative assessment of myocardial ischemia remains a scientific challenge and a clinical goal but time has not come for these newer ultrasonographic techniques which should be restricted to research laboratories.

  18. Echocardiography as an approach for canine cardiac disease diagnosis

    Directory of Open Access Journals (Sweden)

    P. Singh

    2014-11-01

    Full Text Available Aim: The aim of the study was to establish the methods for diagnosis various canine cardiac ailments using echocardiography. Materials and Methods: M-mode, two-dimensional echocardiography and Doppler studies were performed on 10 cases. Dogs showing signs of cardiac ailment either clinically, radiographic or via electrocardiographic examination were selected for study. Right parasternal short axis view was used for echocardiographic measurements. Right parasternal long axis and left parasternal apical views were used for Doppler studies. Doppler studies were performed at the level of aortic valve and atrioventricular valves for semi quantitative diagnosis of regurgitation. Results: Dogs were found affected with dilated cardiomyopathy (DCM (n=5, pericardial effusion (PE (n=1, combined PE and DCM (n=2 and remaining two showed abnormality on radiographic or electrographically evaluation but were found out to be normal echocardiographically (n=2. Conclusion: Echocardiography is an effective tool for diagnosis of various heart ailments.

  19. Two-dimensional color Doppler echocardiography for left ventricular stroke volume assessment: a comparison study with three-dimensional echocardiography.

    Science.gov (United States)

    Silva, Cristina Da; Pedro, Fátima; Deister, Lizandra; Sahlén, Anders; Manouras, Aristomenis; Shahgaldi, Kambiz

    2012-08-01

    Whether measurement of left ventricular outflow tract diameter (LVOTd) using color Doppler (CD) in order to more accurately define LVOTd is more accurate for determination of stroke volume (SV) than gray scale and compare it with direct measurement of LVOT area (a) using three-dimensional echocardiography (3DE) for SV determination. Twenty-one volunteers were examined. LVOTa was calculated by two-dimensional echocardiography (2DE) using the following formula: π× (d/2)(2) , d = LVOT diameter by gray scale and CD, respectively. Planimetry of LVOTa was performed in parasternal long axis using 3DE. Eccentricity Index was calculated using the lateral and anterior-posterior LVOTd. SV was obtained by four different methods: (1) 2D gray scale, (2) 2D color, (3) LVOTa × LVOT velocity time integral, and (4) SV by Simpson's biplane method. Gray scale LVOTd was significantly smaller compared to LVOTd obtained with CD (P vs 3.67 ± 0.70 cm(2) , P vs 3.61 ± 0.89 cm(2) , P = 0.011). Half of the subjects had at least 17% difference between the lateral and anterior-posterior LVOTd. There were significant differences between SV by 2D gray scale and 2D CD (82.8 ± 17.1 mL vs 92.4 ± 16.8 mL, P vs 90.7 ± 19.8 mL, P = 0.025). Our study demonstrates LVOT being frequently elliptical. SV and LVOTa were found to be similar when comparing 2DE CD and 3DE planimetry and showed higher values in comparison to 2DE gray scale, which suggests 2DE CD to be an alternative approach for SV assessment. © 2012, Wiley Periodicals, Inc.

  20. Recent advances in echocardiography for nuclear medicine physician

    International Nuclear Information System (INIS)

    Hong, Geu Ru; Shin, Dong Gu

    2005-01-01

    Echocardiography is one of the most frequently used techniques for diagnosing cardiovascular diseases. Over the last twenty years, technological advances have enabled the application of high-quality imaging. Important recent developments have occurred in echocardiography that are already being used clinically. Equipment and hardware is now available to produce real time three-dimensional and contrast enhanced imaging. Tissue Doppler and stress echocardiography have provided potential benefit to analyze hemodynamic information of heart. This review discusses each of these new developments and their potential impact on the practice of echocardiography and cardiology in general

  1. Pulsed-wave transmitral Doppler do not diagnose moderate acute rejection after heart transplantation

    NARCIS (Netherlands)

    Mannaerts, H. F.; Simoons, M. L.; Balk, A. H.; Tijssen, J.; van der Borden, S. G.; Zondervan, P. E.; Mochtar, B.; Weimar, W.; Roelandt, J. R.

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously

  2. PULSED-WAVE TRANSMITRAL DOPPLER DO NOT DIAGNOSE MODERATE ACUTE REJECTION AFTER HEART-TRANSPLANTATION

    NARCIS (Netherlands)

    MANNAERTS, HF; SIMOONS, ML; BALK, AH; TIJSSEN, J; VANDERBORDEN, SG; ZONDERVAN, PE; MOCHTAR, B; WEIMAR, W; ROELANDT, [No Value

    1993-01-01

    The value of pulsed-wave transmitral Doppler for the diagnosis of moderate acute rejection was examined in a total of 347 Doppler recordings obtained in 32 consecutive cardiac allograft recipients. Serial Doppler examinations (median, 11 per patient; range, 1 to 23) were performed simultaneously

  3. Time series analysis of continuous-wave coherent Doppler Lidar wind measurements

    DEFF Research Database (Denmark)

    Sjöholm, Mikael; Mikkelsen, Torben; Mann, Jakob

    2008-01-01

    The influence of spatial volume averaging of a focused 1.55 mu m continuous-wave coherent Doppler Lidar on observed wind turbulence measured in the atmospheric surface layer over homogeneous terrain is described and analysed. Comparison of Lidar-measured turbulent spectra with spectra simultaneou......The influence of spatial volume averaging of a focused 1.55 mu m continuous-wave coherent Doppler Lidar on observed wind turbulence measured in the atmospheric surface layer over homogeneous terrain is described and analysed. Comparison of Lidar-measured turbulent spectra with spectra...

  4. Doppler-guided retrograde catheterization system

    Science.gov (United States)

    Frazin, Leon J.; Vonesh, Michael J.; Chandran, Krishnan B.; Khasho, Fouad; Lanza, George M.; Talano, James V.; McPherson, David D.

    1991-05-01

    The purpose of this study was to investigate a Doppler guided catheterization system as an adjunctive or alternative methodology to overcome the disadvantages of left heart catheterization and angiography. These disadvantages include the biological effects of radiation and the toxic and volume effects of iodine contrast. Doppler retrograde guidance uses a 20 MHz circular pulsed Doppler crystal incorporated into the tip of a triple lumen multipurpose catheter and is advanced retrogradely using the directional flow information provided by the Doppler waveform. The velocity detection limits are either 1 m/second or 4 m/second depending upon the instrumentation. In a physiologic flow model of the human aortic arch, multiple data points revealed a positive wave form when flow was traveling toward the catheter tip indicating proper alignment for retrograde advancement. There was a negative wave form when flow was traveling away from the catheter tip if the catheter was in a branch or bent upon itself indicating improper catheter tip position for retrograde advancement. In a series of six dogs, the catheter was able to be accurately advanced from the femoral artery to the left ventricular chamber under Doppler signal guidance without the use of x-ray. The potential applications of a Doppler guided retrograde catheterization system include decreasing time requirements and allowing safer catheter guidance in patients with atherosclerotic vascular disease and suspected aortic dissection. The Doppler system may allow left ventricular pressure monitoring in the intensive care unit without the need for x-ray and it may allow left sided contrast echocardiography. With pulse velocity detection limits of 4 m/second, this system may allow catheter direction and passage into the aortic root and left ventricle in patients with aortic stenosis. A modification of the Doppler catheter may include transponder technology which would allow precise catheter tip localization once the

  5. [Pulmonary artery pressure evaluation in adults by Doppler echocardiography].

    Science.gov (United States)

    Campos Filho, O; Andrade, J L; Carvalho, A C; Luna Filho, B; Pfeferman, A; Arroyo, J B; Leão, L E; Martinez Filho, E E

    1991-04-01

    To assess the role of pulsed Doppler echocardiography (PDE) in the indirect assessment of pulmonary artery (PA) pressure (P), analysing the pulmonary velocity blood flow curves (PVBFC) profile. Sixty-one adults with several kinds of heart disease were submitted to heart catheterization to obtain PAP (systolic, diastolic, mean), and other hemodynamic variables. A PDE examination was performed in all to obtain the PVBFC at the level of the pulmonic annulus. Qualitative features of the curve were analysed (morphological pattern, presence of pulmonic regurgitation) as well as quantitative data (acceleration time = AT, right ventricle ejection time = RVET index, AT/RVET index AT corrected for heart rate = ATC), which were compared to the invasive measurements. An abnormal rapid acceleration of the PVBFC, with triangular configuration, was noted in patient with pulmonary hypertension (PH), in contrast to the dome-like shape of the PVBFC in normal PAP. Pulmonary regurgitation was more frequent (p less than 0.05) in patients with severe PH (mean PAP greater than or equal to 40 mmHg), comparing with patients with PAP less than 40 mmHg. Inverse linear correlations were observed between AT and mean PAP, particularly when sinus rhythm was present (r = 0.89; p less than 0.05) excluding patients with atrial fibrilation (19 cases). PDE is an useful and noninvasive method for indirect evaluation of PAP in adults, especially during stable sinus rhythm, in heart rate range from 60 to 115 bpm.

  6. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Maulik, D.

    2005-01-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  7. Doppler ultrasound in obstetrics and gynecology. 2. rev. and enl. ed.

    Energy Technology Data Exchange (ETDEWEB)

    Maulik, D. [Winthrop Univ. Hospital, Mineola, NY (United States). Dept. of Obstetrics and Gynecology; Zalud, I. (eds.) [Kapiolani Medical Center for Women and Children, Honolulu, HI (United States)

    2005-07-01

    The second edition of Doppler Ultrasound in Obstetrics and Gynecology has been expanded and comprehensively updated to present the current standards of practice in Doppler ultrasound and the most recent developments in the technology. Doppler Ultrasound in Obstetrics and Gynecology encompasses the full spectrum of clinical applications of Doppler ultrasound for the practicing obstetrician-gynecologist, including the latest advances in 3D and color Doppler and the newest techniques in 4D fetal echocardiography. Written by preeminent experts in the field, the book covers the basic and physical principles of Doppler ultrasound; the use of Doppler for fetal examination, including fetal cerebral circulation; Doppler echocardiography of the fetal heart; and the use of Doppler for postdated pregnancy and in cases of multiple gestation. Chapters on the use of Doppler for gynecologic investigation include ultrasound in ectopic pregnancy, for infertility, for benign disorders and for gynecologic malignancies. (orig.)

  8. Correlation Between Doppler Echocardiography and Right Heart Catheterization Derived Pulmonary Artery Pressures: Impact of Right Atrial Pressures

    International Nuclear Information System (INIS)

    Ahmed, I.; Nuri, M. M. H.; Zakariyya, A. N.; Ahmad, S. M.; Ahmed, M.

    2016-01-01

    Objective: To evaluate the correlation between Doppler echocardiography (DE) and right heart catheterization (RHC) derived pulmonary artery pressures and to assess the impact of right atrial (RA) pressures on this correlation. Study Design: Cross-sectional analytical study. Place and Duration of Study: Cardiology Department, Tahir Heart Institute, Chenab Nagar, from June 2013 to December 2014. Methodology: All patients undergoing RHC were included. Relevant data were collected from hospital database. Continuous variables were expressed as the mean and SD or as the median and interquartile range where the distributions were skewed. Pearson correlation coefficient and Bland-Altman method were used to correlate DE derived right ventricular systolic pressure (RVSP) and RHC derived systolic pulmonary artery pressures (sPAP). Adjusted RVSP was calculated by replacing default value of RA pressure (10 mmHg) with RHC derived mean RA pressure. Receiver operating characteristic curve (ROC) was used to identify the best cut-off value of RVSP in predicting pulmonary hypertension. Results: Fifty-one patients completed the study protocol. Mean age of study population was 45.22 ± 15.25 years with male to female ratio of 1.47:1. Median error was 13 mmHg (7 to 20). Pearson correlation coefficient (r) between RVSP and sPAP was 0.72. Bland-Altman method of correlation showed bias of +4.43 mmHg with 95% limits of agreement ranging from -34.61 to +43.47. Using ROC curve, the best cut-off value of RVSP was greater than 52 mmHg with accuracy of 75% (sensitivity: 81%, specificity: 69%) in predicting pulmonary hypertension. Adjusted RVSP showed only little improvement in correlation (r = 0.75), adjusted error (13.65 ± 13.05) and diagnostic accuracy (79%). Conclusion: Doppler echocardiography can frequently overestimate pulmonary artery pressures. Though correctly estimated RA pressure may improve this correlation, yet its contribution is only minimal. (author)

  9. Contrast echocardiography: history, micro bubble characteristics and instrumental techniques

    International Nuclear Information System (INIS)

    Cubides, Carlos; Restrepo, Gustavo; Aristizabal, Dagnovar; Munera, Ana

    2006-01-01

    This article describes the history of contrast echocardiography, the physical characteristics of the contrast agent's micro bubbles, the main instrumental tools (mechanical index, focus and focusing, frame rate), and the echocardiography techniques (second harmonic imaging, fusion harmonic, power pulse inversion imaging, triggered imaging, intermittent harmonic power Doppler, color power angio and acoustic densitometry), actually available for clinical use

  10. Full-wave Simulation of Doppler Reflectometry in the Presence of Turbulence

    Energy Technology Data Exchange (ETDEWEB)

    Lechte, C. [Institut fur Plasmaforschung, Universitat Stuttgart, Stuttgart (Germany)

    2011-07-01

    Doppler reflectometry is a microwave plasma diagnostic well suited for density fluctuation measurement. A meaningful interpretation of Doppler reflectometry measurements necessitates the analysis of the wave propagation in the plasma using simulations methods. While the beam path can usually be reconstructed with beam tracing methods, the modeling of the scattering process demands the use of wave simulation codes. Furthermore, in the presence of strong density fluctuations, the response from the plasma is dominated by dispersion and multiple scattering, and hence becomes non-linear. IPF-FD3D is the finite difference time domain code used to investigate the dependence of the scattering efficiency on the various plasma conditions. It uses the full set of Maxwell equations and the electron equation of motion in a cold plasma. First results in slab geometry indicate a strong dependence of the scattering efficiency on the density gradient, the incident angle, and the wave polarisation. Further complications arise with the introduction of broadband turbulent fluctuations, where additional knowledge of the radial spectrum is necessary to reconstruct the full fluctuation spectrum from Doppler reflectometry measurements. This paper presents the reconstruction of the turbulent fluctuation spectrum from simulated Doppler reflectometry measurements in slab geometry. Two cases of analytical turbulence in slab geometry are presented where the fluctuation wavenumber spectrum was recovered. It is planned to extend these investigations to X mode polarization and to supplement actual fusion experiments

  11. Left coronary arterial blood flow: Noninvasive detection by Doppler US

    International Nuclear Information System (INIS)

    Gramiak, R.; Holen, J.; Moss, A.J.; Gutierrez, O.H.; Picone, A.L.; Roe, S.A.

    1986-01-01

    Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left coronary artery can be distinguished by its blood flow toward the cardiac apex and by specific, functional flow features. Flow patterns vary among the left main, circumflex, and anterior descending arteries; patterns also vary with respiration cycles. In the present study, coronary arterial blood flow was detected in 58 of 70 patients (83%). Findings were validated by selectively injecting an agitated saline contrast medium into the left coronary artery and, in another study, by comparing human Doppler phasic flow waveforms with electromagnetic flowmeter recordings obtained in dogs

  12. Cardiac output by Doppler echocardiography in the premature baboon: Comparison with radiolabeled microspheres

    International Nuclear Information System (INIS)

    Kinsella, J.P.; Morrow, W.R.; Gerstmann, D.R.; Taylor, A.F.; deLemos, R.A.

    1991-01-01

    Pulsed-Doppler echocardiography (PDE) is a useful noninvasive method for determining left ventricular output (LVO). However, despite increasingly widespread use in neonatal intensive care units, validation studies in prematures with cardiopulmonary disease are lacking. The purpose of this study was to compare radiolabeled microsphere (RLM) and PDE measurements of LVO, using the critically ill premature baboon as a model of the human neonate. Twenty-two paired RLM and PDE measurements of LVO were obtained in 14 animals between 3 and 24 h of age. Average PDE LVO was 152 ml/min/kg (range, 40-258 ml/min/kg) compared to 158 ml/min/kg (range, 67-278 ml/min/kg) measured by RLM. Linear regression analysis of the paired measurements showed good correlation with a slope near unity (gamma = 0.94x + 4.20, r = 0.91, SEE = 25.7 ml). The authors conclude that PDE determinations of LVO compare well with those measured by RLM in the premature baboon. PDE appears to provide a valid estimate of LVO and should be useful in human prematures with cardiopulmonary distress

  13. Usefulness and limitations of transthoracic echocardiography in heart transplantation recipients

    Directory of Open Access Journals (Sweden)

    Galderisi Maurizio

    2008-01-01

    Full Text Available Abstract Transthoracic echocardiography is a primary non-invasive modality for investigation of heart transplant recipients. It is a versatile tool which provides comprehensive information about cardiac structure and function. Echocardiographic examinations can be easily performed at the bedside and serially repeated without any patient's discomfort. This review highlights the usefulness of Doppler echocardiography in the assessment of left ventricular and right ventricular systolic and diastolic function, of left ventricular mass, valvular heart disease, pulmonary arterial hypertension and pericardial effusion in heart transplant recipients. The main experiences performed by either standard Doppler echocardiography and new high-tech ultrasound technologies are summarised, pointing out advantages and limitations of the described techniques in diagnosing acute allograft rejection and cardiac graft vasculopathy. Despite the sustained efforts of echocardiographic technique in predicting the biopsy state, endocardial myocardial biopsies are still regarded as the gold standard for detection of acute allograft rejection. Conversely, stress echocardiography is able to identify accurately cardiac graft vasculopathy and has a recognised prognostic in this clinical setting. A normal stress-echo justifies postponement of invasive studies. Another use of transthoracic echocardiography is the monitorisation and the visualisation of the catheter during the performance of endomyocardial biopsy. Bedside stress echocardiography is even useful to select appropriately heart donors with brain death. The ultrasound monitoring is simple and effective for monitoring a safe performance of biopsy procedures.

  14. Tissue Doppler echocardiography in persons with hypertension, diabetes, or ischaemic heart disease: the Copenhagen City Heart Study

    DEFF Research Database (Denmark)

    Mogelvang, Rasmus; Sogaard, Peter; Pedersen, Sune A

    2009-01-01

    AIMS: To test the hypothesis that echocardiographic tissue Doppler imaging (TDI) reveals reduced myocardial function in hypertension, diabetes, and ischaemic heart disease (IHD) in the general population. METHODS AND RESULTS: Within a large, community-based population study, cardiac function...... and diastolic cardiac function in hypertension [n = 345; LD 10.1 (+/-standard deviation, SD 2.0 mm), P diabetes [n = 65; LD 9.8 (+/-SD 2.2 mm), P ....001] compared with controls [n = 533; LD 11.4 (+/-SD 2.0 mm); E/e' 9.0 (x/SD 1.3)]. This pattern remained significant after adjusting for age, sex, body mass index, heart rate, and the results of conventional echocardiography. CONCLUSION: In the general population, persons with hypertension, diabetes, or IHD...

  15. Novel techniques in stress echocardiography: a focus on the advantages and disadvantages.

    Science.gov (United States)

    Vamvakidou, Anastasia; Gurunathan, Sothinathan; Senior, Roxy

    2016-01-01

    Stress echocardiography (SE) is an established tool not only for the assessment of coronary artery disease (CAD), but also for the evaluation of valvular disease and cardiomyopathy. New techniques, namely contrast echocardiography for function and perfusion including assessment of coronary flow reserve, strain imaging, 3-dimensional echocardiography, Doppler-derived coronary flow reserve and multimodality echocardiography, have been incorporated into stress protocols for improving assessment of cardiac disease. In this review, the advantages and disadvantages of these novel SE techniques are examined in terms of feasibility, accuracy, reproducibility and applications.

  16. [Doppler echocardiography of tricuspid insufficiency. Methods of quantification].

    Science.gov (United States)

    Loubeyre, C; Tribouilloy, C; Adam, M C; Mirode, A; Trojette, F; Lesbre, J P

    1994-01-01

    Evaluation of tricuspid incompetence has benefitted considerably from the development of Doppler ultrasound. In addition to direct analysis of the valves, which provides information about the mechanism involved, this method is able to provide an accurate evaluation, mainly through use of the Doppler mode. In addition to new criteria being evaluated (mainly the convergence zone of the regurgitant jet), some indices are recognised as good quantitative parameters: extension of the regurgitant jet into the right atrium, anterograde tricuspid flow, laminar nature of the regurgitant flow, analysis of the flow in the supra-hepatic veins, this is only semi-quantitative, since the calculation of the regurgitation fraction from the pulsed Doppler does not seem to be reliable; This accurate semi-quantitative evaluation is made possible by careful and consistent use of all the criteria available. The authors set out to discuss the value of the various evaluation criteria mentioned in the literature and try to define a practical approach.

  17. Right Ventricular Doppler Echocardiographic Study of Indeterminate Form of Chagas Disease

    Directory of Open Access Journals (Sweden)

    Rogério Gomes Furtado

    2015-03-01

    Full Text Available Background: Patients with indeterminate form of Chagas disease/cardiac normality (ICD/CN exhibited normal electrocardiograms and chest X-rays; however, more sophisticated tests detected some degree of morphological and functional changes in the heart. Objective: To assess the prevalence of systolic and diastolic dysfunction of the right ventricle (RV in patients with ICD/CN. Methods: This was a case–control and prevalence study. Using Doppler two-dimensional echocardiography (2D, 92 patients were assessed and divided into two groups: group I (normal, n = 31 and group II (ICD/CN, n = 61. Results: The prevalence of RV systolic dysfunction in patients in groups I and II was as follows: fractional area change (0.0% versus 0.6%, mobility of the tricuspid annulus (0.0% versus 0.0%, and S-wave tissue Doppler (6.4% versus 26.0%, p = 0.016. The prevalence of global disorders such as the right myocardial performance index using tissue Doppler (16.1% versus 27.8%, p = 0.099 and pulsed Doppler (61.3% versus 68%, p = 0.141 and diastolic disorders such as abnormal relaxation (0.0% versus 6.0%, pseudonormal pattern (0.0% versus 0.0%, and restrictive pattern (0.0% versus 0.0% was not statistically different between groups. Conclusion: The prevalence of RV systolic dysfunction was estimated to be 26% (S wave velocity compared with other variables, suggesting incipient changes in RV systolic function in the ICD/CN group.

  18. MRI and echocardiography in the diagnosis of cardiac amyloidosis

    International Nuclear Information System (INIS)

    Wang Jing; Kong Xiangquan; Zhou Guofeng; Xu Haibo; Chang Dandan; Feng Yiming; Liu Dingxi; Zhang Li; Xie Mingxing

    2010-01-01

    Objective: To assess the values of MRI and echocardiography for the diagnosis of cardiac amyloidosis (CA). Methods: Eleven cases with CA proved pathologically performed MRI and echocardiography, the findings were analyzed retrospectively. Results: The characteristic features of cardiac amyloidosis on MRI and echocardiography were: diffuse slight myocardial thickening of the left ventricular wall and interventricular septum (11 cases), slight myocardial thickening of the interatrial septum (5 cases), increased left ventricular mass (7 cases), enlarged left atrium (7 cases), impaired ventricular systolic and diastolic function (10 cases), pleural and pericardial effusions (11 and 9 cases). Echocardiography showed that myocardium was hyperechoic and presented as ground glass with some spotty hyperechoes in 6 cases. MRI revealed a distinct diffuse delayed enhancement of subendocardial and entire myocardium in 8 cases. Conclusion: Doppler echocardiography is the first-choice imaging technique and cardiac magnetic resonance imaging can provide more information for the diagnosis of CA. (authors)

  19. Associations between thoracic radiographic changes and severity of pulmonary arterial hypertension diagnosed in 60 dogs via Doppler echocardiography: A retrospective study.

    Science.gov (United States)

    Adams, Dustin S; Marolf, Angela J; Valdés-Martínez, Alejandro; Randall, Elissa K; Bachand, Annette M

    2017-07-01

    Doppler echocardiography is a noninvasive method for estimating and grading pulmonary arterial hypertension. No current literature associates significance of radiographic findings with severity of pulmonary arterial hypertension. We hypothesized that the number and conspicuity of radiographic findings suggestive of pulmonary arterial hypertension would be greater based on the severity of pulmonary arterial hypertension. Dogs with pulmonary arterial hypertension and normal control dogs were included in this retrospective, case control study. Three radiologists blinded to echocardiographic results scored thoracic radiographs for right ventricular and main pulmonary artery enlargement and pulmonary lobar artery enlargement, tortuosity, and blunting by multiple methods. Presence or absence of each finding was scored in an additive fashion and averaged for each grade of pulmonary arterial hypertension severity. Seventy-one dogs (60 dogs with pulmonary arterial hypertension and 11 control dogs) of which some had multiple studies were included: 20 mild, 21 moderate, 25 severe, and 11 absent pulmonary arterial hypertension. The following radiographic findings were significantly associated with increasing pulmonary arterial hypertension severity: right ventricular enlargement by "reverse D" and "3/5-2/5 cardiac ratio" methods, main pulmonary artery enlargement, and caudal lobar artery enlargement by the "3rd rib" method. Mean scores for severe pulmonary arterial hypertension and normal dogs were significantly different (P-value < 0.0001). Mean scores between different pulmonary arterial hypertension grades increased with severity but were not statistically significant. Individually and in combination, radiographic findings performed poorly in differentiating severity of pulmonary arterial hypertension. Findings indicated that thoracic radiographs should be utilized in conjunction with Doppler echocardiography in a complete diagnostic work-up for dogs with suspected

  20. Two-dimensional and Doppler echocardiographic findings in healthy non-sedated red-eared slider terrapins (Trachemys scripta elegans).

    Science.gov (United States)

    Poser, H; Russello, G; Zanella, A; Bellini, L; Gelli, D

    2011-12-01

    Echocardiographic evaluation was performed in six healthy young adult non-sedated terrapins (Trachemys scripta elegans). The best imaging quality was obtained through the right cervical window. Base-apex inflow and outflow views were recorded, ventricular size, ventricular wall thickness and ventricular outflow tract were measured, and fractional shortening was calculated. Pulsed-wave Doppler interrogation enabled the diastolic biphasic atrio-ventricular flow and the systolic ventricular outflow patterns to be recorded. The following Doppler-derived functional parameters were calculated: early diastolic (E) and late diastolic (A) wave peak velocities, E/A ratio, ventricular outflow systolic peak and mean velocities and gradients, Velocity-Time Integral, acceleration and deceleration times, and Ejection Time. For each parameter the mean, standard deviation and 95% confidence interval were calculated. Echocardiography resulted as a useful and easy-to-perform diagnostic tool in this poorly known species that presents difficulties during evaluation.

  1. Pulsed and Tissue Doppler Echocardiographic Changes in Patients with Thalassemia Major

    Directory of Open Access Journals (Sweden)

    Taysir S. Garadah

    2010-01-01

    Full Text Available Background Doppler echocardiographic studies of left ventricle (LV systolic and diastolic function in patients with β-Thalassemia Major (β-TM had shown different patterns of systolic and diastolic dysfunction. Aim This cross-sectional study was designed to study the LV systolic and diastolic function in patients with β-TM using Pulsed Doppler (PD and Tissue Doppler (TD echocardiography. Methods All patients were evaluated clinically and by echocardiography, The study included patients with β-TM (n = 38, age 15.7 ± 8.9 years compared with an age-matched control group (n = 38, age 15.9 ± 8.9 years. The pulse Doppler indices were normalized for age and heart rate. Results Compared with control patients, M-Mode showed that patients with β-TM have thicker LV septal wall index (0.659 ± 0.23 vs. 0.446 ± 0.219 cm, P ≤ 0.001, posterior wall index (0.659 ± 0.235 vs. 0.437 ± 0.214 cm, P ≤ 0.01, and larger LVEDD index is (3.99 ± 0.48 vs. 2.170 ± 0.57 mm. P = 0.035. Pulsed Doppler showed high LV trans-mitral E wave velocity (70.818 ± 10.139 vs. 57.532 ± 10.139, p = 0.027 and E/A ratio (1.54 vs. 1.23, P ≤ 0.01. The duration of Deceleration time (DT and isovolumic relaxation time (IVRT were significantly shorter in patients with β-TM (150.234 ± 20.0.23 vs. 167.123 ± 19.143 msec, P ≤ 0.01 and (60.647 ± 6.77 vs. 75.474 ± 5.83 msec, P ≤ 0.001, respectively. The ratio of transmitral E wave velocity to the tissue Doppler E wave at the basal septal mitral annulus E/Em – was significantly higher in β-TM group (14.024 ± 2.29 vs. 12.132 ± 1.82, P ≤ 0.01. The Tissue Doppler systolic velocity (Sm and the early diastolic velocity (Em were significantly lower in β-TM group compared to control (4.31 ± 1.2 cm/s vs. 6.95 ± 2.1, P ≤ 0.01 and 4.31 ± 2.7 cm/s vs. 5.82 ± 2.5, P ≤ 0.01 respectively. The tricuspid valve velocity was significantly higher than controls (2.993 ± 0.569 vs. 1.93 ± 0.471 m/sec, respectively, P ≤ 0

  2. Integrated quadruple stress echocardiography.

    Science.gov (United States)

    Picano, Eugenio; Morrone, Doralisa; Scali, Maria C; Huqi, Alda; Coviello, Katia; Ciampi, Quirino

    2018-04-11

    Stress Echocardiography (SE) is an established diagnostic technique. For 40 years, the cornerstone of the technique has been the detection of regional wall motion abnormalities (RWMA), due to the underlying physiologically-relevant epicardial coronary artery stenosis. In the last decade, three new parameters (more objective than RWMA) have shown the potential to integrate and comple- ment RWMA: 1- B-lines, also known as ultrasound lung comets, as a marker of extra-vascular lung water, measured using lung ultrasound with the 4-site simplified scan symmetrically of the antero- lateral thorax on the third intercostal space, from mid-axillary to anterior axillary and mid- clavicular line; 2-left ventricular contractile reserve (LVCR), assessed as the peak stress/rest ratio of left ventricular force, also known as elastance (systolic arterial pressure by cuff sphygmomanome- ter/end-systolic volume from 2D echocardiography); 3- coronary flow velocity reserve (CFVR) on left anterior descending coronary artery, calculated as peak stress/rest ratio of diastolic peak flow velocity assessed using pulsed-wave Doppler. The 4 parameters (RWMA, B-lines, LVCR and CFVR) now converge conceptually, logistically, and methodologically in the Integrated Quadruple (IQ)-SE. IQ-SE optimizes the versatility of SE to include in a one-stop shop the core "ABCD" (Asynergy+B-lines+Contractile reserve+Doppler flowmetry) protocol. It allows a synoptic assess- ment of parameters mirroring the epicardial artery stenosis (RWMA), interstitial lung water (B- lines), myocardial function (LVCR) and small coronary vessels (CFVR). Each variable has a clear clinical correlate, different and complementary to all others: RWMA identify an ischemic vs non- ischemic heart; B-lines a wet vs dry lung; LVCR a strong vs weak heart; CFVR a warm vs cold heart. IQ-SE is highly feasible, with minimal increase in the imaging and analysis time, and obvi- ous diagnostic and prognostic impact also beyond coronary artery

  3. Role of Echocardiography in the Management and Prognosis of Atrial Fibrillation

    Science.gov (United States)

    Silverman, David I; Ayirala, Srilatha R; Manning, Warren J

    2012-01-01

    Echocardiography plays a longstanding and vital role in the management of atrial fibrillation (AF). Advances in 2D imaging, Doppler echocardiography and strain imaging have all contributed to major progress in AF treatment. Echocardiographically measured left atrial (LA) volume is a powerful predictor of maintenance of sinus rhythm following cardioversion as well as risk of thrombus formation and thromboembolism. Doppler derived parameters of atrial mechanical function including atrial ejection force provide related prognostic information. Transesophageal echocardiocardiograpy (TEE) guided cardioversion of AF allows for rapid conversion to sinus rhythm without prolonged oral anticoagulation, and TEE serves as a useful tool during catheter ablation of AF and atrial flutter. Newer measures derived from speckle tracking offer great promise in further improving the care of patients with AF. PMID:28496715

  4. Utility of Angle Correction for Hemodynamic Measurements with Doppler Echocardiography.

    Science.gov (United States)

    Sigurdsson, Martin I; Eoh, Eun J; Chow, Vinca W; Waldron, Nathan H; Cleve, Jayne; Nicoara, Alina; Swaminathan, Madhav

    2018-04-06

    The routine application angle correction (AnC) in hemodynamic measurements with transesophageal echocardiography currently is not recommended but potentially could be beneficial. The authors hypothesized that AnC can be applied reliably and may change grading of aortic stenosis (AS). Retrospective analysis. Single institution, university hospital. During phase I, use of AnC was assessed in 60 consecutive patients with intraoperative transesophageal echocardiography. During phase II, 129 images from a retrospective cohort of 117 cases were used to quantify AS by mean pressure gradient. A panel of observers used custom-written software in Java to measure intra-individual and inter-individual correlation in AnC application, correlation with preoperative transthoracic echocardiography gradients, and regrading of AS after AnC. For phase I, the median AnC was 21 (16-35) degrees, and 17% of patients required no AnC. For phase II, the median AnC was 7 (0-15) degrees, and 37% of assessed images required no AnC. The mean inter-individual and intra-individual correlation for AnC was 0.50 (95% confidence interval [CI] 0.49-0.52) and 0.87 (95% CI 0.82-0.92), respectively. AnC did not improve agreement with the transthoracic echocardiography mean pressure gradient. The mean inter-rater and intra-rater agreement for grading AS severity was 0.82 (95% CI 0.81-0.83) and 0.95 (95% CI 0.91-0.95), respectively. A total of 241 (7%) AS gradings were reclassified after AnC was applied, mostly when the uncorrected mean gradient was within 5 mmHg of the severity classification cutoff. AnC can be performed with a modest inter-rater and intra-rater correlation and high degree of inter-rater and intra-rater agreement for AS severity grading. Copyright © 2018 Elsevier Inc. All rights reserved.

  5. Cardiac MR imaging: Comparison with echocardiography and dynamic CT

    International Nuclear Information System (INIS)

    Colletti, P.M.; Norris, S.; Raval, J.; Boswell, W.; Lee, K.; Ralls, P.; Haywood, J.; Halls, J.

    1986-01-01

    The authors compared gated cardiac MR imaging with two-dimensional and Doppler echocardiography and dynamic CT. Gated cardiac MR imaging (VISTA unit, 0.5 T) was performed in 55 patients with a variety of conditions. Accuracy of diagnosis was compared. CT showed arterial, valvular, and pericardial calcifications not seen on MR imaging. Many lesions were seen as well on CT as on MR imaging. Two-dimensional echocardiography was superior in demonstrating wall motion and valvular disease. MR imaging was superior in demonstrating myocardial structures

  6. The usefulness of contrast during exercise echocardiography for the assessment of systolic pulmonary pressure

    Directory of Open Access Journals (Sweden)

    Cordeiro Ana

    2008-10-01

    Full Text Available Abstract Background The systolic pulmonary artery pressure (PAPs can be accurately estimated, non-invasively, using continuous-wave Doppler (CWD ultrasound measurement of the peak velocity of a tricuspid regurgitant (TR jet. However, it is often difficult to obtain adequate tricuspid regurgitation signals for measurement of PAPs, what could lead to its underestimation. Therefore, utilization of air-blood-saline contrast has been implemented for the improvement of Doppler signal in several clinical contexts. It is now recommended in the evaluation of patients with pulmonary hypertension. Physical activity is severely restricted in patients with PAH, being exertional dypnea the most typical symptom. Exercise stress echo-Doppler imaging allows assessment of the response to exercise. It is an excellent screening test for patients with suspected PAH. Our purpose was to evaluate the value and accuracy of agitated saline with blood contrast echocardiography, in the improvement of the Doppler signal, to quantify PAPs during treadmill exercise-echocardiography. Purpose To evaluate the value of contrast echocardiography, using agitated saline with blood, in the improvement of the Doppler signal used to quantify the pulmonary artery systolic pressure during exercise. Methods From a total of 41 patients (pts, we studied 38 pts (93%, 35 women, aged 54 ± 12 years-old. 27 with the diagnosis of systemic sclerosis, 10 with history of pulmonary embolism and one patient with a suspected idiopathic PAH, who were referred to the Unity of Heart Failure and Pulmonary Hypertension for screening of PAH. According to the Unity protocol, a transthoracic echocardiogram was made, in left decubitus (LD, with evaluation of right ventricle-right atria gradient (RV/RAg. A peripheral venous access was obtained, with a 3-way stopcock and the patients were placed in orthostatism (O, with a new evaluation of RV/RAg. Exercise echocardiography (EE was begun, with evaluation of RV

  7. The mechanism of mid-latitude Pi2 waves in the upper ionosphere as revealed by combined Doppler and magnetometer observations

    Directory of Open Access Journals (Sweden)

    V. A. Pilipenko

    2013-04-01

    Full Text Available The interpretation of simultaneous ionospheric Doppler sounding and ground magnetometer observations of low-latitude Pi2 waves is revised. We compare the theoretical estimates of the ionospheric Doppler velocity for the same amplitude of the ground magnetic disturbances produced by a large-scale compressional mode and an Alfvén mode. The plasma vertical displacement caused by the wave electric field is shown to be the dominating effect. Taking into account the correction of the previous paper, the observations of low-latitude Pi2 in the F layer ionosphere by Doppler sounding and SuperDARN (Super Dual Auroral Radar Network radars give consistent results. We suggest that the Doppler response to Pi2 waves is produced by the Alfvén wave component, but not the fast-mode component, whereas the ground magnetic signal is composed from both Alfvén and fast magnetosonic modes.

  8. Evaluation of left ventricular function by tissue Doppler and speckle-derived strain rate echocardiography after percutaneous ductus closure.

    Science.gov (United States)

    Amoogzar, Hamid; Shakiba, Ali Mohammad; Derakhshan, Dorna; Ajami, Gholamhossein; Cheriki, Sirous; Borzouee, Mohammad; Edraki, Mohammad Reza; Mehdizadegan, Nima

    2015-01-01

    The aim of this study was to evaluate the left ventricular systolic and diastolic function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure. 21 children (age >6 months old) diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler and tissue Doppler imaging and speckled-derived strain rate echocardiography were done at pre-closure, 1 day (early) and 1 month (late) post-closure. Mean age of the patients (female/male: 1.3) was 17.54 ± 24.7 months with the mean PDA diameter of 3.6 ± 0.8 mm. Systolic measures (ejection fraction, shortening fraction) reduced significantly early after PDA closure (P closure status. Early and late diastolic flow velocities of mitral (E M and A M) reduced considerably in early and late post-closure time (P closure. After 1 month, E'M increased considerably. (P = 0.01) but E'M/A'M had an insignificant rise (P > 0.05). E M/E'M ratio did not change in early post-closure but it had a considerable reduction in the subsequent month compared with the pre- and early post-closure (P closure (P closure causes a significant decrease in left ventricular performance early after PDA closure which recovers completely within 1 month. Also PDA size can affect post-closure left ventricular function.

  9. Intracardiac echocardiography: use during transcatheter device closure of a patent ductus arteriosus in a dog.

    Science.gov (United States)

    Chetboul, V; Damoiseaux, C; Behr, L; Morlet, A; Moise, N S; Gouni, V; Lavennes, M; Pouchelon, J-L; Laborde, F; Borenstein, N

    2017-06-01

    Intracardiac echocardiography (ICE) is used in humans for percutaneous interventional procedures, such as transcatheter device closures. Intracardiac echocardiography provides high-resolution imaging of cardiac structures with two-dimensional, M-mode, Doppler, and also three-dimensional modalities. The present report describes application of ICE during transcatheter occlusion of patent ductus arteriosus using a canine ductal occluder in a dog for which transesophageal echocardiography could not provide an optimal acoustic window. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Imaging the heart: cardiac scintigraphy and echocardiography in US hospitals (1983)

    International Nuclear Information System (INIS)

    McPhee, S.J.; Garnick, D.W.

    1986-01-01

    The rapid growth of cardiac catheterization has raised questions about the availability of less costly, noninvasive tests such as cardiac scintigraphy and echocardiography. To assess their availability and rates of use, we surveyed 3778 non-federal short-term US hospitals in June, 1983. Overall, 2605 hospitals (69%) offered 201 Tl myocardial perfusion scans, 2580 (68%) 99mTc equilibrium gated blood pool scans, and 2483 (67%) cardiac shunt scans; 1679 hospitals (44%) offered M-mode and/or 2-dimensional echocardiography, and 768 (20%) pulsed Doppler echocardiography. Volumes of procedures varied enormously among hospitals capable of performing them. High volumes of both scintigraphy and echocardiography were performed in a small number of hospitals. Larger, voluntary, and teaching hospitals performed higher volumes of both procedures. Despite widespread availability of these noninvasive technologies, high volumes of both cardiac scintigraphy and echocardiography procedures are concentrated in a small number of US hospitals

  11. Evaluation of postoperative pulmonary regurgitation after surgical repair of tetralogy of Fallot: comparison between Doppler echocardiography and MR velocity mapping

    Energy Technology Data Exchange (ETDEWEB)

    Grothoff, Matthias; Spors, Birgit; Gutberlet, Matthias [Charite Campus Virchow Klinikum, Department of Radiology and Nuclear Medicine, Berlin (Germany); Abdul-Khaliq, Hasim [Deutsches Herzzentrum, Department of Congenital Heart Disease/Pediatric Cardiology, Berlin (Germany)

    2008-02-15

    Pulmonary regurgitation is a common finding in patients after correction of tetralogy of Fallot (TOF). Right ventricular impairment and even ventricular arrhythmia have been ascribed to pulmonary valve insufficiency (PI), which is therefore an important issue in follow-up examinations. To compare PI measured by echocardiography (ECHO) with data provided by cardiac MRI (CMR). We studied 54 selected patients (18 female; median age 14.0 years, range 3.8-53.4 years) after surgical correction of TOF. To quantify pulmonary regurgitant fraction (PRF) by CMR, flow velocity mapping was performed. On Doppler ECHO, length, width and localization of regurgitant flow was measured. The severity of PI was categorized as mild, moderate or severe and compared to the data obtained by CMR. On CMR the mean PRF was 29.2 {+-} 13.4%. Patients with a transannular patch had a significantly higher PRF (39.9 {+-} 11.6%) than patients with an intact annular ring (23.6 {+-} 11.4%). Differentiation by Doppler ECHO between the categories mild, moderate and severe PI was confirmed by significant differences in PRF measured by CMR (mild vs. moderate P < 0.04; moderate vs. severe P < 0.014; mild vs. severe P < 0.001). Furthermore, PRF correlated with right ventricular end diastolic volume index (r = 0.45, P < 0.01) and right ventricular end systolic volume index (r = 0.39, P < 0.01). Doppler ECHO can estimate the severity of PI after repair of TOF with acceptable results compared to CMR flow measurement. In univariate analysis there is only a weak influence of PRF on right ventricular volume. (orig.)

  12. Performance of two-dimensional Doppler echocardiography for the assessment of infarct size and left ventricular function in rats

    Directory of Open Access Journals (Sweden)

    Nozawa E.

    2006-01-01

    Full Text Available Although echocardiography has been used in rats, few studies have determined its efficacy for estimating myocardial infarct size. Our objective was to estimate the myocardial infarct size, and to evaluate anatomic and functional variables of the left ventricle. Myocardial infarction was produced in 43 female Wistar rats by ligature of the left coronary artery. Echocardiography was performed 5 weeks later to measure left ventricular diameter and transverse area (mean of 3 transverse planes, infarct size (percentage of the arc with infarct on 3 transverse planes, systolic function by the change in fractional area, and diastolic function by mitral inflow parameters. The histologic measurement of myocardial infarction size was similar to the echocardiographic method. Myocardial infarct size ranged from 4.8 to 66.6% when determined by histology and from 5 to 69.8% when determined by echocardiography, with good correlation (r = 0.88; P < 0.05; Pearson correlation coefficient. Left ventricular diameter and mean diastolic transverse area correlated with myocardial infarct size by histology (r = 0.57 and r = 0.78; P < 0.0005. The fractional area change ranged from 28.5 ± 5.6 (large-size myocardial infarction to 53.1 ± 1.5% (control and correlated with myocardial infarct size by echocardiography (r = -0.87; P < 0.00001 and histology (r = -0.78; P < 00001. The E/A wave ratio of mitral inflow velocity for animals with large-size myocardial infarction (5.6 ± 2.7 was significantly higher than for all others (control: 1.9 ± 0.1; small-size myocardial infarction: 1.9 ± 0.4; moderate-size myocardial infarction: 2.8 ± 2.3. There was good agreement between echocardiographic and histologic estimates of myocardial infarct size in rats.

  13. Angiographically borderline left main coronary artery lesions: correlation of transthoracic doppler echocardiography and intravascular ultrasound: a pilot study

    Directory of Open Access Journals (Sweden)

    Varga Albert

    2011-06-01

    Full Text Available Abstract Background the clinical decision making could be difficult in patients with borderline lesions (visually assessed stenosis severity of 30 to 50% of the left main coronary artery (LM. The aim of the study was to evaluate the relationship between transthoracic Doppler (TTDE peak diastolic flow velocity (PDV and intravascular ultrasound (IVUS measurements in the assessment of angiographically borderline LM lesions. Methods 27 patients (mean age 64 ± 8 years, 21 males with borderline LM stenosis referred for IVUS examination were included in the study. We performed standard IVUS with minimal lumen area (MLA and plaque burden (PB measurement and routine quantitative coronary angiography (QCA with diameter stenosis (%DS and area stenosis (%AS assessment in all. During TTDE, resting PDV was measured in the LM. Results interpretable Doppler signal could be obtained in 24 patients (88% feasibility; therefore these patients entered the final analysis. MLA was 7.1 ± 2.7 mm2. TTDE measured PDV correlated significantly with IVUS-derived MLA (r = -0.46, p 2 LM stenosis. Conclusion In angiographically borderline LM disease, resting PDV from transthoracic echocardiography is increased in presence of increased plaque burden by IVUS. TTDE evaluation might be a useful adjunct to other invasive and non-invasive methods in the assessment of borderline LM lesions. Further, large scale studies are needed to establish the exact cut-off value of PDV for routine clinical application.

  14. A brief history of fetal echocardiography and its impact on the management of congenital heart disease.

    Science.gov (United States)

    Maulik, Dev; Nanda, Navin C; Maulik, Devika; Vilchez, Gustavo

    2017-12-01

    Congenital heart disease (CHD), the most common congenital malformation, is associated with adverse outcome. Development of fetal echocardiography has made prenatal diagnosis of CHD a reality, and in the process revolutionized its management. This historical review briefly narrates this development over the decades focusing on the emergence of the primary modalities of fetal echocardiography comprised of the time-motion mode, two-dimensional B-mode, spectral Doppler, color Doppler, and three- and four-dimensional cardiac imaging. Collaboration between clinicians and engineers has been central to these advances. Also discussed are the accuracy and impact of fetal echocardiography on the management of CHD, and especially its role in the prenatal diagnosis of critical CHD in individualizing the management and improving the outcome. Despite these advances, most cases of CHD are not identified prenatally, emphasizing the continuing need for further technological and educational innovation and improvement. © 2017, Wiley Periodicals, Inc.

  15. Evaluation of postoperative pulmonary regurgitation after surgical repair of tetralogy of Fallot: comparison between Doppler echocardiography and MR velocity mapping

    International Nuclear Information System (INIS)

    Grothoff, Matthias; Spors, Birgit; Gutberlet, Matthias; Abdul-Khaliq, Hasim

    2008-01-01

    Pulmonary regurgitation is a common finding in patients after correction of tetralogy of Fallot (TOF). Right ventricular impairment and even ventricular arrhythmia have been ascribed to pulmonary valve insufficiency (PI), which is therefore an important issue in follow-up examinations. To compare PI measured by echocardiography (ECHO) with data provided by cardiac MRI (CMR). We studied 54 selected patients (18 female; median age 14.0 years, range 3.8-53.4 years) after surgical correction of TOF. To quantify pulmonary regurgitant fraction (PRF) by CMR, flow velocity mapping was performed. On Doppler ECHO, length, width and localization of regurgitant flow was measured. The severity of PI was categorized as mild, moderate or severe and compared to the data obtained by CMR. On CMR the mean PRF was 29.2 ± 13.4%. Patients with a transannular patch had a significantly higher PRF (39.9 ± 11.6%) than patients with an intact annular ring (23.6 ± 11.4%). Differentiation by Doppler ECHO between the categories mild, moderate and severe PI was confirmed by significant differences in PRF measured by CMR (mild vs. moderate P < 0.04; moderate vs. severe P < 0.014; mild vs. severe P < 0.001). Furthermore, PRF correlated with right ventricular end diastolic volume index (r = 0.45, P < 0.01) and right ventricular end systolic volume index (r = 0.39, P < 0.01). Doppler ECHO can estimate the severity of PI after repair of TOF with acceptable results compared to CMR flow measurement. In univariate analysis there is only a weak influence of PRF on right ventricular volume. (orig.)

  16. Detection of congenital heart disease by fetal echocardiography

    International Nuclear Information System (INIS)

    Fayyaz, A.; Majeed, S.M.I.

    2013-01-01

    Objective: The objective of the study was to determine the sensitivity, specificity, accuracy and predictive value of fetal echocardiography in our set up using postnatal echocardiography as gold standard. Study Design: Validation study. Place and Duration of study: This is an ongoing study in the Radiology department of CMH Rawalpindi and Armed Forces Institute of Cardiology (AFIC) Rawalpindi and the data collected from January 2007 to Jan 2012 is presented. Patients and Methods: Two hundred eighty seven patients reported for fetal echocardiography. Two hundred twenty nine patients were subsequently included in the study. These included patients of all ages who reported to the Radiology department of CMH Rawalpindi for fetal echocardiography. Fetal echo was done on Toshiba Aplio with 3.5 MHz probe having Doppler facility. Post natal evaluation was done by a pediatric cardiologist. Results: There were 207 (90.4%) true negative cases, 15 (6.6%) true positive, 2 (0.9%) false positive and 6 (2.2%) false negative cases. The sensitivity, specificity, positive and negative predictive values were 75%, 99%, 88%, 97% respectively. Conclusion: Fetal echocardiography has high specificity, negative predictive values and accuracy and cases diagnosed as normal can reassure the parents about the normal cardiac status of the fetus. (author)

  17. Acceleration rate of mitral inflow E wave: a novel transmitral doppler index for assessing diastolic function.

    Science.gov (United States)

    Badkoubeh, Roya Sattarzadeh; Tavoosi, Anahita; Jabbari, Mostafa; Parsa, Amir Farhang Zand; Geraeli, Babak; Saadat, Mohammad; Larti, Farnoosh; Meysamie, Ali Pasha; Salehi, Mehrdad

    2016-06-10

    We performed comprehensive transmitral and pulmonary venous Doppler echocardiographic studies to devise a novel index of diastolic function. This is the first study to assess the utility of the acceleration rate (AR) of the E wave of mitral inflow as a primary diagnostic modality for assessing diastolic function. Study group consisted of 84 patients (53 + 11 years) with left ventricle (LV) diastolic dysfunction and 34 healthy people (35 ± 9 years) as control group, who were referred for clinically indicated two-dimensional transthoracic echocardiogram (TTE) during 2012 and 2013 to Imam Hospital. Normal controls were defined as patients without clinical evidence of cardiac disease and had normal TTE. LV diastolic function was determined according to standardized protocol of American Society of Echocardiography (ASE). As our new parameter, AR of E wave of mitral inflow was also measured in all patients. It was represented by the slope of the line between onset of E wave and peak of it. Correlation between AR of E wave and LV diastolic function grade was measured using the Spearman correlation coefficient. Receiver operating characteristic (ROC) curve was used to determine the sensitivity and specificity of AR of E wave in diagnosing LV diastolic dysfunction in randomly selected two-thirds of population then its derived cutoff was evaluated in rest of the population. The institutional review board of the hospital approved the study protocol. All participants gave written informed consent. This investigation was in accordance with the Declaration of Helsinki. The mean value of AR was 1010 ± 420 cm/s(2) in patients whereas the mean value for the normal controls was 701 ± 210 cm/s(2). There was a strong and graded relation between AR of E wave of mitral inflow and LV diastolic function grade (Spearman P ≤0.0001, rs =0.69). ROC curve analysis revealed that AR of E wave of mitral inflow =750 cm/s(2) predicted moderate or severe LV diastolic

  18. Challenges in noise removal from Doppler spectra acquired by a continuous-wave lidar

    DEFF Research Database (Denmark)

    Angelou, Nikolas; Foroughi Abari, Farzad; Mann, Jakob

    2012-01-01

    are presented. A method for determining the background noise spectrum without interrupting the transmission of the laser beam is described. Moreover, the dependency between the determination of the threshold of a Doppler spectrum with low signal-to-noise ratios and the characteristics of the wind flow......This paper is focused on the required post processing of Doppler spectra, acquired from a continuous-wave coherent lidar at high sampling rates (400 Hz) and under rapid scanning of the laser beam. In particular, the necessary steps followed for extracting the wind speed from such Doppler spectra...... are investigated and a systematic approach for removing the noise is outlined. The suggested post processing procedures are applied to two sample time series acquired by a short-range WindScanner during one second each....

  19. The use of echocardiography in Wolff-Parkinson-White syndrome.

    Science.gov (United States)

    Cai, Qiangjun; Shuraih, Mossaab; Nagueh, Sherif F

    2012-04-01

    Endocardial mapping and radiofrequency catheter ablation are well established modalities for the diagnosis and treatment of patients with Wolff-Parkinson-White (WPW) syndrome associated with tachyarrhythmias. However, the electrophysiologic techniques are invasive, require radiation exposure, and lack spatial resolution of cardiac structures. A variety of echocardiographic techniques have been investigated as a non-invasive alternative for accessory pathway localization. Conventional M-mode echocardiography can detect the fine premature wall motion abnormalities associated with WPW syndrome. However, it is unable to identify the exact site of accessory pathway with sufficient accuracy. 2D, 2D-guided M-mode, and 2D phase analysis techniques are limited by image quality and endocardial border definition. Various modalities of tissue Doppler echocardiography significantly increase the accuracy of left-sided accessory pathway localization to 80-90% even in patients with poor acoustic window. However, right-sided pathways remain a diagnostic challenge. Strain echocardiography by speckle tracking has recently been evaluated and appears promising. Different cardiac abnormalities have been detected by echocardiography in WPW patients. Patients with WPW syndrome and tachyarrhythmias have impaired systolic and diastolic function which improves after radiofrequency ablation. Echocardiography is useful in identifying patient with accessory pathway-associated left ventricular dyssynchrony and dysfunction who may benefit from ablation therapy. Transesophageal and intracardiac echocardiography have been used to guide ablation procedure. Ablation-related complications detected by routine echocardiography are infrequent, rarely clinically relevant, and of limited value.

  20. Effect of preload alternations on a new Doppler echocardiographic index of combined systolic and diastolic performance

    DEFF Research Database (Denmark)

    Møller, J E; Poulsen, S H; Egstrup, K

    1999-01-01

    The objective of the study was to assess the effect of preload alternations on a nongeometric Doppler index of combined systolic and diastolic myocardial performance (MPI). Doppler echocardiography was performed during Valsalva maneuver, passive leg lifting, and after sublingual administration of...

  1. HF doppler sounder measurements of the ionospheric signatures of small scale ULF waves

    Directory of Open Access Journals (Sweden)

    L. J. Baddeley

    2005-07-01

    Full Text Available An HF Doppler sounder, DOPE (DOppler Pulsation Experiment with three azimuthally-separated propagation paths is used to provide the first statistical examination of small scale-sized, high m waves where a direct measurement of the azimuthal wavenumber m, is made in the ionosphere. The study presents 27 events, predominantly in the post-noon sector. The majority of events are Pc4 waves with azimuthal m numbers ranging from –100 to –200, representing some of the smallest scale waves ever observed in the ionosphere. 4 Pc5 waves are observed in the post-noon sector. The fact that measurements for the wave azimuthal m number and the wave angular frequency are available allows the drift-bounce resonance condition to be used to hypothesise potential particle populations which could drive the waves through either a drift or drift-bounce resonance interaction mechanism. These results are compared with the statistical study presented by Baddeley et al. (2004 which investigated the statistical likelihood of such driving particle populations occurring in the magnetospheric ring current. The combination of these two studies indicates that any wave which requires a possible drift resonance interaction with particles of energies >60 keV, is statistically unlikely to be generated by such a mechanism. The evidence presented in this paper therefore suggests that in the pre-noon sector the drift-bounce resonance mechanism is statistically more likely implying an anti-symmetric standing wave structure while in the post-noon sector both a drift or drift-bounce resonance interaction is statistically possible, indicating both symmetric and anti-symmetric standing mode structures. A case study is also presented investigating simultaneous observations of a ULF wave in ground magnetometer and DOPE data. The event is in the lower m range of the statistical study and displays giant pulsation (Pg characteristics.

    Keywords

  2. HF doppler sounder measurements of the ionospheric signatures of small scale ULF waves

    Directory of Open Access Journals (Sweden)

    L. J. Baddeley

    2005-07-01

    Full Text Available An HF Doppler sounder, DOPE (DOppler Pulsation Experiment with three azimuthally-separated propagation paths is used to provide the first statistical examination of small scale-sized, high m waves where a direct measurement of the azimuthal wavenumber m, is made in the ionosphere. The study presents 27 events, predominantly in the post-noon sector. The majority of events are Pc4 waves with azimuthal m numbers ranging from –100 to –200, representing some of the smallest scale waves ever observed in the ionosphere. 4 Pc5 waves are observed in the post-noon sector. The fact that measurements for the wave azimuthal m number and the wave angular frequency are available allows the drift-bounce resonance condition to be used to hypothesise potential particle populations which could drive the waves through either a drift or drift-bounce resonance interaction mechanism. These results are compared with the statistical study presented by Baddeley et al. (2004 which investigated the statistical likelihood of such driving particle populations occurring in the magnetospheric ring current. The combination of these two studies indicates that any wave which requires a possible drift resonance interaction with particles of energies >60 keV, is statistically unlikely to be generated by such a mechanism. The evidence presented in this paper therefore suggests that in the pre-noon sector the drift-bounce resonance mechanism is statistically more likely implying an anti-symmetric standing wave structure while in the post-noon sector both a drift or drift-bounce resonance interaction is statistically possible, indicating both symmetric and anti-symmetric standing mode structures. A case study is also presented investigating simultaneous observations of a ULF wave in ground magnetometer and DOPE data. The event is in the lower m range of the statistical study and displays giant pulsation (Pg characteristics. Keywords. Ionosphere (Ionosphere

  3. New sub-Doppler absorption resonances in a thin gas cell produced by means of a running monochromatic wave

    International Nuclear Information System (INIS)

    Tajalli, H; Ahmadi, S; Izmailov, A Ch

    2002-01-01

    A theoretical investigation is carried out through the interaction of the plane running monochromatic light wave, having an arbitrary intensity, with atoms (molecules) of a rarefied gas in the plane cell (at the normal incidence of the wave). Cases of closed and open resonance transitions from the non-degenerate ground (or metastable) quantum level are considered. Possible sub-Doppler resonances are analysed in the wave absorption, caused by the transient establishment of the optical coherence on the transition, Rabi oscillations between its levels, and optical pumping during the free flights of particles between the walls of the cell. Results of the previous works on given problems are generalized, which were obtained at definite restrictions on the wave intensity and cell length. Moreover, non-trivial sub-Doppler spectral structures, resulting as a consequence of the dependence of the absorption saturation on the transit relaxation of particles, have been established and investigated. Such structures may consist of a number of peaks and dips caused by Rabi oscillations between the transition levels. The results obtained can be used in sub-Doppler spectroscopy and for the stabilization of laser frequencies in thin gas cells

  4. Doppler radar flowmeter

    Science.gov (United States)

    Petlevich, Walter J.; Sverdrup, Edward F.

    1978-01-01

    A Doppler radar flowmeter comprises a transceiver which produces an audio frequency output related to the Doppler shift in frequency between radio waves backscattered from particulate matter carried in a fluid and the radiated radio waves. A variable gain amplifier and low pass filter are provided for amplifying and filtering the transceiver output. A frequency counter having a variable triggering level is also provided to determine the magnitude of the Doppler shift. A calibration method is disclosed wherein the amplifier gain and frequency counter trigger level are adjusted to achieve plateaus in the output of the frequency counter and thereby allow calibration without the necessity of being able to visually observe the flow.

  5. Time series analysis of continuous-wave coherent Doppler Lidar wind measurements

    International Nuclear Information System (INIS)

    Sjoeholm, M; Mikkelsen, T; Mann, J; Enevoldsen, K; Courtney, M

    2008-01-01

    The influence of spatial volume averaging of a focused 1.55 μm continuous-wave coherent Doppler Lidar on observed wind turbulence measured in the atmospheric surface layer over homogeneous terrain is described and analysed. Comparison of Lidar-measured turbulent spectra with spectra simultaneously obtained from a mast-mounted sonic anemometer at 78 meters height at the test station for large wind turbines at Hoevsoere in Western Jutland, Denmark is presented for the first time

  6. Ekhokardiografi Endokardiosis Penyakit Katup Mitral Jantung Anjing (ECHOCARDIOGRAPHY OF ENDOCARDIOSIS MITRAL VALVE HEART DISEASE IN DOGS

    Directory of Open Access Journals (Sweden)

    Deni Noviana

    2013-08-01

    Full Text Available Endocardiosis is a disease commonly found in Pomeranian dog characterized by progressive myxomatousdegeneration of the atrio-ventricular valves especially in the mitral valve. The purpose of this study was todefine the diagnose and severeity of this disease on the Pomeranian by using brightness mode, motion mode,dan color flow Doppler echocardiography technique. Echocardiography was performed on 8 Pomeranianconsisting of 6 males and 2 females with age range of 2-14 years. Brightness mode echocardiography wasused to see the echotexture of endocardium, mitral valve, and the valve movement. The results showedendocardium thickening, along with chronic fibrosis and nodular thickening of the anterior and posteriormitral valve leaflet. Three out of seven cases showed prolapsed of the mitral valve. Motion modeechocardiography was performed in order to measure left ventricle internal dimension, myocardium thickness,fractional shortening, left atrial and aortic dimension. The results showed myocardium thickening, alongwith left atrial enlargement. Color flow Doppler echocardiography was used to confirm the mitral valveregurgitation. Three of seven cases showed the presence of regurgitation signed by turbulence color of theprolapsed mitral valve. Based on the degree of severity, scoring system used in this study, endocardiosis canbe divided into three types that are mild, moderate and severe.

  7. Doppler-Defined Pulmonary Hypertension in Sickle Cell Anemia in Kurdistan, Iraq.

    Science.gov (United States)

    Al-Allawi, Nasir; Mohammad, Ameen M; Jamal, Shakir

    2016-01-01

    To determine the frequency, clinical and laboratory associations of pulmonary hypertension in Iraqi Kurds with sickle cell anemia, a total of ninety four such patients attending a major hemoglobinopathy center in Iraqi Kurdistan were enrolled. All patients were re-evaluated clinically and had their blood counts, HbF, serum ferritin, LDH, renal and liver function assessed. Transthoracic Doppler echocardiography with measurement of tricuspid valve regurgitant jet velocity (TRV) was performed. A TRV in excess of 2.8 m/s was considered for the purposes of this study as indicative of pulmonary hypertension (PH). The prevalence of TRV in excess of 2.8m/s was 10.6%. By univariate analysis: significantly higher reticulocyte count, more frequent blood transfusions and pain episodes were encountered in the PH group as compared to the non-PH group (p = 0.001, 0.045 and 0.02 respectively). Moreover, PH patients had significantly higher mean right atrial area, left atrial size, E wave/A wave ratio and ejection fraction by echocardiography (p = 0.027, 0.037, <0.001 and 0.008 respectively). Except for reticulocyte count none of the other parameters remained significant by multivariate analysis (p = 0.024). In conclusion the current study revealed that pulmonary hypertension is rather frequent among Iraqi Kurds with sickle cell anemia, and identified reticulocyte count as an independently associated parameter with PH in this population. Future prospective studies including right heart catheterization and appropriate medical intervention are warranted.

  8. Patient-exposure data for doppler ultrasound

    International Nuclear Information System (INIS)

    Stewart, H.F.; Silvis, P.X.; Smith, S.W.

    1986-01-01

    In recent years ultrasound imaging and Doppler blood flow measurements have become important tools for use in diagnostic medicine. Commercial pulse-echo imaging equipment was first introduced into commerce in 1963. The first commercial continuous wave Doppler unit was introduced to the marketplace in 1966. As equipment improved and applications developed, the industry experienced rapid growth in the 1970s. One of the more recent growth areas in the application of diagnostic ultrasound has been the use of pulsed Doppler equipment for cardiac applications. Prior to 1976, some continuous wave Doppler ultrasound was used for cardiovascular diagnosis. However, only a single manufacturer marketed a pulsed Doppler clinical instrument for cardiac or peripheral vascular diagnosis. Currently, many continuous wave and pulsed Doppler instruments are commercially available for both peripheral vascular and cardiac diagnosis. This chapter (1) briefly reviews current safety guidelines, regulations, and recommendations for diagnostic ultrasound; (2) discusses the patient-exposure intensities associated with Doppler ultrasound medical equipment and compare these levels of exposure with intensities from other medical ultrasound devices; and (3) considers some of the current information as it relates to the safety of diagnostic ultrasound

  9. Time interval between maternal electrocardiogram and venous Doppler waves in normal pregnancy and preeclampsia: a pilot study.

    Science.gov (United States)

    Tomsin, K; Mesens, T; Molenberghs, G; Peeters, L; Gyselaers, W

    2012-12-01

    To evaluate the time interval between maternal electrocardiogram (ECG) and venous Doppler waves at different stages of uncomplicated pregnancy (UP) and in preeclampsia (PE). Cross-sectional pilot study in 40 uncomplicated singleton pregnancies, categorized in four groups of ten according to gestational age: 10 - 14 weeks (UP1), 18 - 23 weeks (UP2), 28 - 33 weeks (UP3) and ≥ 37 weeks (UP4) of gestation. A fifth group of ten women with PE was also included. A Doppler flow examination at the level of renal interlobar veins (RIV) and hepatic veins (HV) was performed according to a standard protocol, in association with a maternal ECG. The time interval between the ECG P-wave and the corresponding A-deflection of the venous Doppler waves was measured (PA), and expressed relative to the duration of the cardiac cycle (RR), and labeled PA/RR. In hepatic veins, the PA/RR is longer in UP 4 than in UP 1 (0.48 ± 0.15 versus 0.29 ± 0.09, p ≤ 0.001). When all UP groups were compared, the PA/RR increased gradually with gestational age. In PE, the HV PA/RR is shorter than in UP 3 (0.25 ± 0.09 versus 0.42 ± 0.14, p advanced gestational stages are consistent with known features of maternal cardiovascular adaptation. Shorter values in preeclampsia are consistent with maternal cardiovascular maladaptation mechanisms. Our pilot study invites more research of the relevance of the time interval between maternal ECG and venous Doppler waves as a new parameter for studying the gestational cardiovascular (patho)physiology of the maternal venous compartment by duplex sonography. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Sub-Doppler spectroscopy

    International Nuclear Information System (INIS)

    Hansch, T.W.

    1983-01-01

    This chapter examines Doppler-free saturation spectroscopy, tunable cw sources, and Doppler-free two-photon spectroscopy. Discusses saturation spectroscopy; continuous wave saturation spectroscopy in the ultraviolet; and two-photon spectroscopy of atomic hydrogen 1S-2S. Focuses on Doppler-free laser spectroscopy of gaseous samples. Explains that in saturation spectroscopy, a monochromatic laser beam ''labels'' a group of atoms within a narrow range of axial velocities through excitation or optical pumping, and a Doppler-free spectrum of these selected atoms is observed with a second, counterpropagating beam. Notes that in two-photon spectroscopy it is possible to record Doppler-free spectra without any need for velocity selection by excitation with two counterpropagating laser beams whose first order Doppler shifts cancel

  11. Surgical experience with diseases of the tricuspid valve. Cross-sectional and Doppler echocardiographic evaluation following DeVega's repair.

    Science.gov (United States)

    Kulshrestha, P; Das, B; Iyer, K S; Sampathkumar, A; Sharma, M L; Rao, I M; Kaul, U; Srivastava, S; Bhatia, M L; Venugopal, P

    1989-04-01

    Seventy-eight patients undergoing mitral valve surgery with or without replacement of the aortic valve also underwent procedures on the tricuspid valve over a period of 10 years. All patients were in functional class III or IV preoperatively. The procedures were performed in all patients with organic disease of the tricuspid valve (N = 44) and in those with moderate or severe functional tricuspid valvar regurgitation (N = 34). Seventy-one patients underwent DeVega's annuloplasty with or without commissurotomy. The overall mortality was 11.5%. 65 long-term survivors were followed up for a period of 6 months to 10 years (mean 5.3 years). Sixty-three patients were in functional class I or II at the last follow-up. Six patients had clinical evidence of mild to moderate tricuspid regurgitation. Regression of cardiomegaly (as judged by the chest radiograph and right ventricular hypertrophy seen in the electrocardiogram) was evident in most cases. Fifty-one of 54 patients evaluated by cross-sectional echocardiography were reported to have a functionally normal tricuspid valve. Doppler echocardiography in 28 patients showed no significant tricuspid regurgitation or stenosis in 26 patients. Eleven consecutive patients undergoing DeVega's annuloplasty were studied prospectively with pre- and postoperative Doppler echocardiography. Good correlation existed between right ventricular systolic pressures predicted by Doppler with those obtained preoperatively at cardiac catheterization. Postoperative Doppler echocardiography in these 11 patients showed complete restoration of competence of the tricuspid valve as well as normalisation of the right ventricular systolic pressure in 10 patients.

  12. Avaliação da anastomose de artéria torácica interna esquerda com artéria interventricular anterior pela ecodopplercardiografia Evaluation of left internal thoracic artery anastomosis with left anterior descending coronary artery by Doppler echocardiography

    Directory of Open Access Journals (Sweden)

    Adelaide Arruda

    1997-12-01

    Full Text Available OBJETIVO: Avaliar o valor do ecocardiograma Doppler(ECO transtorácico na identificação de perviabilidade da anastomose entre artéria torácica interna esquerda (ATIE e interventricular anterior, realizada pela técnica de revascularização miocárdica pela minitoracotomia sem circulação extracorpórea. MÉTODOS: Estudaram-se os primeiros 12 pacientes, consecutivos, no período de pós-operatório intra-hospitalar pelo ECO, utilizando-se transdutores de 5MHz, pela via paraesternal esquerda, preferencialmente. Foram analisadas velocidades máximas e integrais de velocidade dos componentes sistólico e diastólico das curvas espectrais de fluxo Doppler. Todos pacientes foram submetidos à cinecoronariografia, enquanto hospitalizados. RESULTADOS: O ECO foi exeqüível em 93% dos pacientes. Nos com anastomose pérvia (6/7, observou-se ao estudo Doppler amplo componente diastólico (padrão A. Naqueles com anastomose obstruída (4/4 o padrão observado foi de predomínio sistólico (padrão B (p=0,003*. CONCLUSÃO: O ECO da ATIE anastomosada com a artéria interventricular anterior, após cirurgia de revascularização miocárdica pela técnica de minitoracotomia, permitiu caracterizar precocemente, com precisão, a perviabilidade da anastomose.PURPOSE: To study the value of Doppler echocardiography as a tool for the evaluation of left internal thoracic artery graft (LITAG patency in patients who underwent coronary revascularization using minimally invasive bypass surgery without extracorporeal circulation. METHODS: The first 12 consecutive patients were studied after coronary artery bypass surgery using a 5MHz Doppler transducer. Doppler signals for the systolic and diastolic flow velocities were preferably obtained in the second intercostal space. All patients underwent coronary angiography while hospitalized. RESULTS: The exam was feasible in 93% of patients. Doppler flow pattern was predominantly diastolic (pattern A in patients with patent

  13. Aortic coarctation diagnosed by renal Doppler flow patterns in a hypertensive young patient: a case report

    International Nuclear Information System (INIS)

    Sari, S.; Kara, K.; Verim, S.

    2012-01-01

    Full text: Introduction: Aortic coarctation is a congenital malformation, which can cause systemic hypertension and subsequent complications, and causes of secondary hypertension, affecting in differential pressures in the upper and lower extremities. Because hypertension is caused by aortic coarctation, tends to be resistant to medical therapy, early recognition and surgical rectification are important. Objectives and tasks: In this article, we aimed to point out that renal Doppler sonography is a beneficial and frequently used to evaluate secondary hypertension, if there are bilateral tardus-parvus wave patterns are detected. Thus, bilateral renal artery stenosis, aortic stenosis, and coarctation should be considered in this condition. Materials and methods: A 23-year-old male who has six-month history of hypertension. He was referred by a cardiologist for investigation of his secondary hypertension. There was an ascending aortic dilatation, left ventricular hypertrophy in his echocardiography. Results: The patient's blood pressure was measured as 160/90 mm Hg in his both arms. Renal Doppler sonography was performed to identify the potential cause of secondary hypertension, specifically renal artery stenosis, after tardus-parvus pulse waves were noted in both renal intralobar-arteries. Aortic coarctation is suspected and then a chest computed tomography (CT) was performed to evaluate supra-diaphragmatic vessel abnormalities. The CT exposed a stenotic lesion in the isthmus of the aorta. The patient was transferred to cardiovascular surgery department for treatment. Conclusion: Careful physical examination should be performed in all hypertensive patients. If bilateral tardus-parvus wave pattern are seen in patients who has been referred for Doppler evaluation on suspicion of renovascular hypertension, aortic coarctation should be considered as differential diagnosis

  14. Flow angle dependent photoacoustic Doppler power spectra under intensity-modulated continuous wave laser excitation

    Directory of Open Access Journals (Sweden)

    Yu Tong

    2016-02-01

    Full Text Available Photoacoustic Doppler (PAD power spectra showing an evident Doppler shift represent the major characteristics of the continuous wave-excited or burst wave-excited versions of PAD flow measurements. In this paper, the flow angle dependences of the PAD power spectra are investigated using an experiment setup that was established based on intensity-modulated continuous wave laser excitation. The setup has an overall configuration that is similar to a previously reported configuration, but is more sophisticated in that it accurately aligns the laser illumination with the ultrasound detection process, and in that it picks up the correct sample position. In the analysis of the power spectra data, we find that the background power spectra can be extracted by combining the output signals from the two channels of the lock-in amplifier, which is very useful for identification of the PAD power spectra. The power spectra are presented and analyzed in opposite flow directions, at different flow speeds, and at different flow angles. The power spectra at a 90° flow angle show the unique properties of symmetrical shapes due to PAD broadening. For the other flow angles, the smoothed power spectra clearly show a flow angle cosine relationship.

  15. Echocardiography Practice: Insights into Appropriate Clinical Use, Technical Competence and Quality Improvement Program

    Science.gov (United States)

    Kossaify, Antoine; Grollier, Gilles

    2014-01-01

    Echocardiography accounts for nearly half of all cardiac imaging techniques. It is a widely available and adaptable tool, as well as being a cost-effective and mainly a non-invasive test. In addition, echocardiography provides extensive clinical data, which is related to the presence or advent of different modalities (tissue Doppler imaging, speckle tracking imaging, three-dimensional mode, contrast echo, etc.), different approaches (transesophageal, intravascular, etc.), and different applications (ie, heart failure/resynchronization studies, ischemia/stress echo, etc.). In view of this, it is essential to conform to criteria of appropriate use and to keep standards of competence. In this study, we sought to review and discuss clinical practice of echocardiography in light of the criteria of appropriate clinical use, also we present an insight into echocardiographic technical competence and quality improvement project. PMID:24516342

  16. Observation of fast-ion Doppler-shifted cyclotron resonance with shear Alfven waves

    International Nuclear Information System (INIS)

    Zhang Yang; Heidbrink, W. W.; Boehmer, H.; McWilliams, R.; Vincena, S.; Carter, T. A.; Gekelman, W.; Leneman, D.; Pribyl, P.

    2008-01-01

    The Doppler-shifted cyclotron resonance (ω-k z v z =Ω f ) between fast ions and shear Alfven waves is experimentally investigated (ω, wave frequency; k z , axial wavenumber; v z , fast-ion axial speed; Ω f , fast-ion cyclotron frequency). A test particle beam of fast ions is launched by a Li + source in the helium plasma of the LArge Plasma Device (LAPD) [W. Gekelman, H. Pfister, Z. Lucky, J. Bamber, D. Leneman, and J. Maggs, Rev. Sci. Instrum. 62, 2875 (1991)], with shear Alfven waves (SAW) (amplitude δ B/B up to 1%) launched by a loop antenna. A collimated fast-ion energy analyzer measures the nonclassical spreading of the beam, which is proportional to the resonance with the wave. A resonance spectrum is observed by launching SAWs at 0.3-0.8ω ci . Both the magnitude and frequency dependence of the beam-spreading are in agreement with the theoretical prediction using a Monte Carlo Lorentz code that launches fast ions with an initial spread in real/velocity space and random phases relative to the wave. Measured wave magnetic field data are used in the simulation.

  17. Role of echocardiography in the evaluation of syncope: a prospective study

    Science.gov (United States)

    Sarasin, F P; Junod, A-F; Carballo, D; Slama, S; Unger, P-F; Louis-Simonet, M

    2002-01-01

    Objective: To study the role of echocardiography in the stepwise evaluation of syncope. Design: A prospective observational study with an 18 month follow up. Setting: University teaching hospital providing primary and tertiary care. Subjects: 650 consecutive patients with syncope and clinical suspicion of an obstructive valvar lesion, or with syncope not explained by history, physical examination, or a 12 lead ECG, who underwent bidimensional Doppler transthoracic echocardiography. Main outcome measures: The causes of syncope were assigned using published diagnostic criteria. Echocardiography was considered diagnostic when confirming a suspected diagnosis, or when revealing occult cardiac disease explaining the syncope. Results: A systolic murmur was identified in 61 of the 650 patients (9%). Severe aortic stenosis was suspected in 20 of these and was confirmed by echocardiography in eight. Follow up excluded further cases of aortic stenosis. In patients with unexplained syncope (n = 155), routine echocardiography showed no abnormalities that established the cause of the syncope. Echocardiography was normal or non-relevant in all patients with a negative cardiac history and a normal ECG (n = 67). In patients with a positive cardiac history or an abnormal ECG (n = 88), echocardiography showed systolic dysfunction (left ventricular ejection fraction ≤ 40%) in 24 (27%) and minor non-relevant findings in the remaining 64. Arrhythmias were diagnosed in 12 of the 24 patients with systolic dysfunction (50%), and in 12 of the 64 remaining patients (19%) (p < 0.01). Conclusions: Echocardiography was most useful for assessing the severity of the underlying cardiac disease and for risk stratification in patients with unexplained syncope but with a positive cardiac history or an abnormal ECG. PMID:12231593

  18. Development of the doppler electron velocimeter: theory.

    Energy Technology Data Exchange (ETDEWEB)

    Reu, Phillip L.

    2007-03-01

    Measurement of dynamic events at the nano-scale is currently impossible. This paper presents the theoretical underpinnings of a method for making these measurements using electron microscopes. Building on the work of Moellenstedt and Lichte who demonstrated Doppler shifting of an electron beam with a moving electron mirror, further work is proposed to perfect and utilize this concept in dynamic measurements. Specifically, using the concept of ''fringe-counting'' with the current principles of transmission electron holography, an extension of these methods to dynamic measurements is proposed. A presentation of the theory of Doppler electron wave shifting is given, starting from the development of the de Broglie wave, up through the equations describing interference effects and Doppler shifting in electron waves. A mathematical demonstration that Doppler shifting is identical to the conceptually easier to understand idea of counting moving fringes is given by analogy to optical interferometry. Finally, potential developmental experiments and uses of a Doppler electron microscope are discussed.

  19. Prognostic value of clinical and Doppler echocardiographic findings in children and adolescents with significant rheumatic valvular disease

    International Nuclear Information System (INIS)

    Araújo, Fátima Derlene da Rocha; Goulart, Eugênio Marcos Andrade; Meira, Zilda Maria Alves

    2012-01-01

    The diagnosis of acute rheumatic fever (RF) is based on clinical findings. However, during the chronic phase of the disease, the clinical approach is not sufficient for the follow-up of the patients and the Doppler echocardiography is a tool for the diagnosis of cardiac involvement. Prognostic variables that influence long-term outcomes are not well known. 462 patients with RF according to Jones criteria were studied, and followed-up from the initial attack to 13.6 ± 4.6 years. All patients underwent clinical assessment and Doppler echocardiography for the detection of heart valve involvement in the acute and chronic phases. Multivariate logistic regression analysis was used to identify the factors influencing long-term heart valve disease. Carditis occurred in 55.8% and subclinical valvulitis in 35.3% patients. In the chronic phase, 33% of the patients had significant valvular heart disease. No normal Doppler echocardiography exam was observed on patients who had severe valvulitis, although heart auscultation had become normal in 13% of these. In the multivariate analysis, only the severity of carditis and the mitral and/or aortic valvulitis were associated with significant valvular heart disease. Chorea or arthritis were protective factors for significant valvular heart disease, odds ratio 0.41 (95% C.I. 0.22 – 0.77) and 0.43 (95% C.I. 0.23 – 0.82), respectively. Our study suggests that the use of Doppler echocardiography during RF helps to identify prognostic factors regarding the development of significant valvular heart disease. Initial severe carditis is an important factor in the long-term prognosis of chronic RHD, whereas arthritis and chore during the initial episode of RF appears to be protective. Strict secondary prophylaxis should be mandatory in high risk patients

  20. Comparisons between PW Doppler system and enhanced FM Doppler system

    DEFF Research Database (Denmark)

    Wilhjelm, Jens E.; Pedersen, P. C.

    1995-01-01

    This paper presents a new implementation of an echo-ranging FM Doppler system with improved performance, relative to the FM Doppler system reported previously. The use of long sweeps provides a significant reduction in peak to average power ratio compared to pulsed wave (PW) emission. A PW Doppler...... system exploits the direct relationship between arrival time of the received signal and range from the transducer. In the FM Doppler systems, a similar relationship exists in the spectral domain of the demodulated received signals, so that range is represented by frequency. Thus, a shift in location...... of moving scatterers between consecutive emissions corresponds to a frequency shift in the spectral signature. The improvement relative to the earlier version of the FM Doppler system is attained by utilizing cross-correlation of real spectra rather than of magnitude spectra for assessing flow velocity...

  1. An evaluation of the use of new Doppler methods for detecting longitudinal function abnormalities in a pacing-induced heart failure model

    Science.gov (United States)

    Tabata, Tomotsugu; Cardon, Lisa A.; Armstrong, Guy P.; Fukamach, Kiyotaka; Takagaki, Masami; Ochiai, Yoshie; McCarthy, Patrick M.; Thomas, James D.

    2003-01-01

    BACKGROUND: Doppler tissue echocardiography and color M-mode Doppler flow propagation velocity have proven useful in evaluating cross-sections of patients with left ventricular (LV) dysfunction, but experience with serial changes is limited. Purpose and methods: We tested their use by evaluating the temporal changes of LV function in a pacing-induced congestive heart failure model. Rapid ventricular pacing was initiated and maintained in 20 dogs for 4 weeks. Echocardiography was performed at baseline and weekly during brief pacing cessation. RESULTS: With rapid pacing, LV volume significantly increased and ejection fraction (57%-28%), stroke volume (37-18 mL), and mitral annulus systolic velocity (16.1-6.6 cm/s) by Doppler tissue echocardiography significantly decreased, with ejection fraction and mitral annulus systolic velocity closely correlated (r = 0.706, P evaluate the serial deterioration in LV dysfunction throughout the pacing period. These were more useful in quantifying progressive LV dysfunction than conventional ehocardiographic techniques, and were probably relatively independent of preload. These techniques could be suitable for longitudinal evaluation in addition to the cross-sectional study.

  2. The Myocardial Performance Index During Low Dose Dobutamine Echocardiography in Normals and Patients With a Recent Myocardial Infarction

    DEFF Research Database (Denmark)

    Nørager, Betina; Husic, Mirza; Møller, Jacob E

    2004-01-01

    BACKGROUND: Wall-motion analysis during low-dose dobutamine echocardiography (LDDE) is a semiquantitative measure of left ventricular contractile reserve after myocardial infarction (MI). The Doppler echocardiographic myocardial performance index (MPI) is a quantitative measure of combined left...

  3. Healed perivalvular abscess: Incidental finding on transthoracic echocardiography

    Directory of Open Access Journals (Sweden)

    Vishnu Datt

    2014-01-01

    Full Text Available A 36-year-old male patient presented with the complaints of palpitations and breathlessness. Preoperative transthoracic echocardiography (TTE revealed a bicuspid aortic valve; severe aortic regurgitation with dilated left ventricle (LV and mild LV systolic dysfunction (ejection fraction 50%. He was scheduled to undergo aortic valve replacement. History was not suggestive of infective endocarditis (IE. Preoperative TTE did not demonstrate any aortic perivalvular abscess. Intraoperative transesophageal echocardiography (TEE examination using the mid-esophageal (ME long-axis view, showed an abscess cavity affecting the aortic valve, which initially was assumed to be a dissection flap, but later confirmed to be an abscess cavity by color Doppler examination. The ME aortic valve short-axis view showed two abscesses; one was at the junction of the non-coronary and left coronary commissure and the other one above the right coronary cusp. Intraoperatively, these findings were confirmed by the surgeons. The case report demonstrates the superiority of TEE over TTE in diagnosing perivalvular abscesses.

  4. Advanced quantitative echocardiography in arrhythmogenic right ventricular cardiomyopathy

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Hastrup Svendsen, Jesper; Sogaard, Peter

    2007-01-01

    BACKGROUND: Arrhythmogenic right ventricular (RV) cardiomyopathy (ARVC) is a regional disease of the RV myocardium with variable degrees of left ventricular involvement. Three-dimensional echocardiography and Doppler tissue imaging (DTI) are new echocardiographic modalities for the evaluation......, patients with ARVC had a decreased RV ejection fraction (0.47 +/- 0.08 vs 0.53 +/- 0.05, P vs 15.1 +/- 3.7 cm/s, P left ventricle (7.0 +/- 2.6 vs 9.5 +/- 1.9 cm/s, P ... of the longitudinal motility appears to be a sensitive marker of preclinical left ventricular involvement....

  5. Evaluation of left ventricular function in obese children without hypertension by a tissue Doppler imaging study.

    Science.gov (United States)

    Ghandi, Yazdan; Sharifi, Mehrzad; Habibi, Danial; Dorreh, Fatemeh; Hashemi, Mojtaba

    2018-01-01

    The prevalence of obesity is increasing worldwide. Obese children without hypertension are becoming an important health challenge. Complications of obesity in adults are well established, but in obese children, cardiac dysfunction has not been reported clinically. The present crosssectional study investigates subclinical systolic and diastolic dysfunction using echocardiographic modalities. Twentyfive youngsters with body mass index (BMI) >30 and 25 healthy children with BMI <25 were assigned into case and control group, respectively. In all participants, complete cardiovascular examination, electrocardiography, and echocardiography were fulfilled. Echocardiography surveys included standard, pulsed wave Doppler (PWD), and tissue Doppler imaging (TDI). SPSS software, version 24. The two groups were matched for age and sex. The resting heart rate and blood pressure were markedly higher in the obese group ( P = 0.0001) though they were within the normal range in either category. Ejection fraction in the two groups was similar. Left ventricular (LV) mass ( P = 0.0001), LV mass index ( P = 0.029), left atrialtoaortic diameter ratio ( P = 0.0001), and LV enddiastolic diameter ( P = 0.008) were significantly greater in the case group, indicating cardiomegaly and subclinical systolic and diastolic dysfunction. Except for the aortic velocity, all PWD variables were considerably lower in the case group, suggesting subclinical diastolic dysfunction. All TDI parameters varied significantly between the two categories. There was a direct correlation between isovolumetric relaxation time and BMI. Obesity in children without hypertension is associated with subclinical systolic and diastolic cardiac dysfunction. We propose the evaluation of blood pressure as well as myocardial performance using PWD and TDI in all obese children without hypertension, regularly.

  6. Comparative analysis of pulsed doppler ultrasonography of portal vein vs indirect photography

    International Nuclear Information System (INIS)

    Chang, Jae Chun; Kwon, Huck Po; Hwang, Mi Soo; Kim, Sun Youn; Park, Bok Hwan; Lee, Hyun Ju; Kim, Hong Jin

    1990-01-01

    There are some limitation of interpretation in indirect photography via superior mesenteric artery. In order to supplement and predict indirect photography, we compared indirect photographic findings with pulsed doppler flowmetry in 38 hepatobiliary patients, and the results were as follow: 1. In case of normal main portal vein(MPV) filling, Pulsed Doppler always showed antegrade, continuous parabolic wave form and cases of abnormal MPV filling, showed unusual wave form and flow direction. 2. In normal filling case of proximal right portal vein, Pulsed Doppler almost showed normal continuous parabolic wave form but in normal filling cases of proximal left portal vein, occasionally showed undulating wave form. 3. In each side proximal portal vein abnormal filling case, we could observe abnormal doppler wave form and could obtain additional information using doppler wave form. 4. Mean portal flow velocity was significantly increased in higher photography grade(p=0.01) and congestion index was significantly decreased in higher photography grade(p=0.01). 5. We concluded that doppler ultrasonography could supplement incomplete indirect photography

  7. Optoheterodyne Doppler measurements of the ballistic expansion of the products of the shock wave-induced surface destruction: Experiment and theory

    International Nuclear Information System (INIS)

    Andriyash, A. V.; Astashkin, M. V.; Baranov, V. K.; Golubinskii, A. G.; Irinichev, D. A.; Kondrat’ev, A. N.; Kuratov, S. E.; Mazanov, V. A.; Rogozkin, D. B.; Stepushkin, S. N.; Khatunkin, V. Yu.

    2016-01-01

    The results of optoheterodyne Doppler measurements of the ballistic expansion of the products of surface destruction under shock-wave loading are presented. The possibility of determining the physical characteristics of a rapidly flying dust cloud, including the microparticle velocities, the microparticle sizes, and the areal density of the dust cloud, is shown. A compact stand for performing experiments on shock-wave loading of metallic samples is described. Shock-wave loading is performed by a 100-µm-thick tantalum flyer plate accelerated to a velocity of 2.8 km/s. As the samples, lead plates having various thicknesses and the same surface roughness are used. At a shock-wave pressure of 31.5 GPa, the destruction products are solid microparticles about 50 µm in size. At a pressure of 42 and 88 GPa, a liquid-drop dust cloud with a particle size of 10–15 µm is formed. To interpret the spectral data on the optoheterodyne Doppler measurements of the expansion of the surface destruction products (spalled fragments, dust microparticles), a transport equation for the function of mutual coherence of a multiply scattered field is used. The Doppler spectra of a backscattered signal are calculated with the model developed for the dust cloud that appears when a shock wave reaches the sample surface at the parameters that are typical of an experimental situation. Qualitative changes are found in the spectra, depending on the optical thickness of the dust cloud. The obtained theoretical results are in agreement with the experimental data.

  8. Optoheterodyne Doppler measurements of the ballistic expansion of the products of the shock wave-induced surface destruction: Experiment and theory

    Energy Technology Data Exchange (ETDEWEB)

    Andriyash, A. V. [All-Russia Research Institute of Automatics (Russian Federation); Astashkin, M. V.; Baranov, V. K.; Golubinskii, A. G.; Irinichev, D. A. [Russian Federal Nuclear Center, All-Russia Research Institute of Experimental Physics (VNIIEF) (Russian Federation); Kondrat’ev, A. N., E-mail: an.kondratev@physics.msu.ru; Kuratov, S. E. [All-Russia Research Institute of Automatics (Russian Federation); Mazanov, V. A. [Russian Federal Nuclear Center, All-Russia Research Institute of Experimental Physics (VNIIEF) (Russian Federation); Rogozkin, D. B. [All-Russia Research Institute of Automatics (Russian Federation); Stepushkin, S. N.; Khatunkin, V. Yu. [Russian Federal Nuclear Center, All-Russia Research Institute of Experimental Physics (VNIIEF) (Russian Federation)

    2016-06-15

    The results of optoheterodyne Doppler measurements of the ballistic expansion of the products of surface destruction under shock-wave loading are presented. The possibility of determining the physical characteristics of a rapidly flying dust cloud, including the microparticle velocities, the microparticle sizes, and the areal density of the dust cloud, is shown. A compact stand for performing experiments on shock-wave loading of metallic samples is described. Shock-wave loading is performed by a 100-µm-thick tantalum flyer plate accelerated to a velocity of 2.8 km/s. As the samples, lead plates having various thicknesses and the same surface roughness are used. At a shock-wave pressure of 31.5 GPa, the destruction products are solid microparticles about 50 µm in size. At a pressure of 42 and 88 GPa, a liquid-drop dust cloud with a particle size of 10–15 µm is formed. To interpret the spectral data on the optoheterodyne Doppler measurements of the expansion of the surface destruction products (spalled fragments, dust microparticles), a transport equation for the function of mutual coherence of a multiply scattered field is used. The Doppler spectra of a backscattered signal are calculated with the model developed for the dust cloud that appears when a shock wave reaches the sample surface at the parameters that are typical of an experimental situation. Qualitative changes are found in the spectra, depending on the optical thickness of the dust cloud. The obtained theoretical results are in agreement with the experimental data.

  9. Mesospheric gravity wave momentum flux estimation using hybrid Doppler interferometry

    Directory of Open Access Journals (Sweden)

    A. J. Spargo

    2017-06-01

    Full Text Available Mesospheric gravity wave (GW momentum flux estimates using data from multibeam Buckland Park MF radar (34.6° S, 138.5° E experiments (conducted from July 1997 to June 1998 are presented. On transmission, five Doppler beams were symmetrically steered about the zenith (one zenith beam and four off-zenith beams in the cardinal directions. The received beams were analysed with hybrid Doppler interferometry (HDI (Holdsworth and Reid, 1998, principally to determine the radial velocities of the effective scattering centres illuminated by the radar. The methodology of Thorsen et al. (1997, later re-introduced by Hocking (2005 and since extensively applied to meteor radar returns, was used to estimate components of Reynolds stress due to propagating GWs and/or turbulence in the radar resolution volume. Physically reasonable momentum flux estimates are derived from the Reynolds stress components, which are also verified using a simple radar model incorporating GW-induced wind perturbations. On the basis of these results, we recommend the intercomparison of momentum flux estimates between co-located meteor radars and vertical-beam interferometric MF radars. It is envisaged that such intercomparisons will assist with the clarification of recent concerns (e.g. Vincent et al., 2010 of the accuracy of the meteor radar technique.

  10. Mesospheric gravity wave momentum flux estimation using hybrid Doppler interferometry

    Science.gov (United States)

    Spargo, Andrew J.; Reid, Iain M.; MacKinnon, Andrew D.; Holdsworth, David A.

    2017-06-01

    Mesospheric gravity wave (GW) momentum flux estimates using data from multibeam Buckland Park MF radar (34.6° S, 138.5° E) experiments (conducted from July 1997 to June 1998) are presented. On transmission, five Doppler beams were symmetrically steered about the zenith (one zenith beam and four off-zenith beams in the cardinal directions). The received beams were analysed with hybrid Doppler interferometry (HDI) (Holdsworth and Reid, 1998), principally to determine the radial velocities of the effective scattering centres illuminated by the radar. The methodology of Thorsen et al. (1997), later re-introduced by Hocking (2005) and since extensively applied to meteor radar returns, was used to estimate components of Reynolds stress due to propagating GWs and/or turbulence in the radar resolution volume. Physically reasonable momentum flux estimates are derived from the Reynolds stress components, which are also verified using a simple radar model incorporating GW-induced wind perturbations. On the basis of these results, we recommend the intercomparison of momentum flux estimates between co-located meteor radars and vertical-beam interferometric MF radars. It is envisaged that such intercomparisons will assist with the clarification of recent concerns (e.g. Vincent et al., 2010) of the accuracy of the meteor radar technique.

  11. Assessment of left atrial appendage function by transthoracic pulsed Doppler echocardiography: Comparing against transesophageal interrogation and predicting echocardiographic risk factors for stroke.

    Science.gov (United States)

    Wai, Shin Hnin; Kyu, Kyu; Galupo, Mary Joyce; Songco, Geronica G; Kong, William K F; Lee, Chi Hang; Yeo, Tiong Cheng; Poh, Kian Keong

    2017-10-01

    Transesophageal echocardiographic (TEE) findings of left atrial appendage (LAA) thrombus, spontaneous echo contrast (SEC), and LAA dysfunction are established risk factors of cardioembolic stroke. The semi-invasive nature of TEE limits its utility as a routine risk stratification tool. We aim to correlate TEE and transthoracic echocardiography (TTE) pulsed Doppler measurements of LAA flow velocities and use TTE measurements to predict TEE findings. We prospectively measured pulsed Doppler LAA flow velocities in 103 consecutive patients on TEE and TTE. There was a strong correlation between TEE and TTE LAA emptying velocity (LAA E) (r = .88, P < .001) and a moderate correlation between LAA filling velocities (r = .50, P < .001). TTE LAA E predicted the presence of thrombus or SEC independent of atrial fibrillation (AF). To predict the presence of thrombus or SEC, the optimal TTE LAA E cutoff was ≤30 cm/s in all patients (75% sensitive, 90% specific) and ≤31 cm/s in AF patients (80% sensitive, 79% specific). To predict LAA dysfunction (TEE E ≤ 20 cm/s), the optimal TTE LAA E cutoff was ≤27 cm/s (100% sensitive, 89% specific in all patients and 100% sensitive, 74% specific in AF patients). TTE assessment of LAA function is feasible and correlates well with the more invasive TEE method. It predicts the presence of thrombus, SEC, and LAA dysfunction on TEE. TTE LAA assessment has incremental value in thromboembolic risk stratification and should be utilized more frequently. © 2017, Wiley Periodicals, Inc.

  12. Diastolic mitral and tricuspid regurgitation by Doppler echocardiography in patients with atrioventricular block: new insight into the mechanism of atrioventricular valve closure.

    Science.gov (United States)

    Schnittger, I; Appleton, C P; Hatle, L K; Popp, R L

    1988-01-01

    The purpose of this study was to prospectively determine the incidence of diastolic mitral and tricuspid regurgitation in atrioventricular (AV) block using Doppler echocardiography. The temporal relation between mitral and tricuspid diastolic insufficiency and the diastolic murmur recorded in patients with complete heart block was also investigated. Twenty-two consecutive patients with AV block (referred to the Echo-Doppler laboratory for routine clinical studies), aged 18 to 87 years, were enrolled in the study. Eleven patients had third degree AV block and a ventricular-inhibited (VVI) pacemaker, two patients had second degree AV block, seven patients had first degree AV block, one patient had blocked premature atrial complexes and one patient had atrial flutter with 4:1 AV block. Diastolic mitral regurgitation was detected in 20 patients, and diastolic tricuspid regurgitation in 21. A mid-diastolic murmur was detected in all patients except in the three youngest. The murmur occurred before diastolic regurgitation and coincided with peak forward flow through the AV valve after atrial contraction. M-mode mitral valve echocardiograms obtained in nine patients demonstrated near closure of some portions of the mitral valve after atrial contraction. Effective closure of the valve, however, did not occur unless ventricular systole supervened. In conclusion, diastolic mitral and tricuspid regurgitation are almost universally present in patients with AV block and are associated with a diastolic murmur. The murmur coincides with forward AV valve flow. Diastolic regurgitation is silent. Effective AV valve closure is not established until ventricular systole occurs, as demonstrated by M-mode echocardiographic recording of the mitral valve.

  13. A coordinated study of 1 h mesoscale gravity waves propagating from Logan to Boulder with CRRL Na Doppler lidars and temperature mapper

    Science.gov (United States)

    Lu, Xian; Chen, Cao; Huang, Wentao; Smith, John A.; Chu, Xinzhao; Yuan, Tao; Pautet, Pierre-Dominique; Taylor, Mike J.; Gong, Jie; Cullens, Chihoko Y.

    2015-10-01

    We present the first coordinated study using two lidars at two separate locations to characterize a 1 h mesoscale gravity wave event in the mesopause region. The simultaneous observations were made with the Student Training and Atmospheric Research (STAR) Na Doppler lidar at Boulder, CO, and the Utah State University Na Doppler lidar and temperature mapper at Logan, UT, on 27 November 2013. The high precision possessed by the STAR lidar enabled these waves to be detected in vertical wind. The mean wave amplitudes are ~0.44 m/s in vertical wind and ~1% in relative temperature at altitudes of 82-107 km. Those in the zonal and meridional winds are 6.1 and 5.2 m/s averaged from 84 to 99 km. The horizontal and vertical wavelengths inferred from the mapper and lidars are ~219 ± 4 and 16.0 ± 0.3 km, respectively. The intrinsic period is ~1.3 h for the airglow layer, Doppler shifted by a mean wind of ~17 m/s. The wave packet propagates from Logan to Boulder with an azimuth angle of ~135° clockwise from north and an elevation angle of ~ 3° from the horizon. The observed phase difference between the two locations can be explained by the traveling time of the 1 h wave from Logan to Boulder, which is about ~2.4 h. The wave polarization relations are examined through the simultaneous quantifications of the three wind components and temperature. This study has developed a systematic methodology for fully characterizing mesoscale gravity waves, inspecting their intrinsic properties and validating the derivation of horizontal wave structures by applying multiple instruments from coordinated stations.

  14. Evaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major.

    Science.gov (United States)

    Saravi, Mehrdad; Tamadoni, Ahmad; Jalalian, Rozita; Mahmoodi-Nesheli, Hassan; Hojati, Mosatafa; Ramezani, Saeed

    2013-01-01

    Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard non-invasive diagnostic test. A total of 100 TM patients with the mean age of 19±7 years and 100 healthy controls 18.8±7 years were evaluated. Conventional echocardiography, TDI, and cardiac MRI T2* were performed in all subjects. TDI measures included myocardial systolic (Sm), early (Em) and late (Am) diastolic velocities at basal and middle segments of septal and lateral LV wall. The TM patients were also subgrouped according to those with iron load (T2* ≤ 20 ms) and those without (T2* > 20 ms), and also severe (T2* ≤ 10 ms) versus the non-severe (T2* ≤ 10 ms). Using T2* cardiovascular MR, abnormal myocardial iron load (T2* ≤ 20 ms) was detected in 84% of the patients and among these, 50% (42/84) had severe (T2* ≤ 10 ms) iron load. The mean T2* was 11.6±8.6 ms (5-36.7). A negative linear correlation existed between transfusion period of patients and T2* levels (r = -0.53, p=0.02). The following TDI measures were lower in patients than in controls: basal septal Am (p<0.05), mid-septal Em and Am (p<0.05), basal lateral Am (p<0.05), mid-lateral LV wall Sm (p<0.05) and Am (p<0.05). Tissue doppler imaging is helpful in predicting the presence of myocardial iron load in Thalassemia patients. Therefore, it can be used for screening of thalassemia major patients.

  15. The Doppler echocardiographic myocardial performance index predicts left-ventricular dilation and cardiac death after myocardial infarction

    DEFF Research Database (Denmark)

    Møller, J E; Søndergaard, E; Poulsen, S H

    2001-01-01

    To investigate the value of the Doppler-derived myocardial performance index to predict early left-ventricular (LV) dilation and cardiac death after a first acute myocardial infarction (AMI), Doppler echocardiography was performed within 24 h of hospital admission, on day 5, 1 and 3 months after...... AMI in 125 consecutive patients. The index measured on day 1 correlated well with the change in end-diastolic volume index observed from day 1 to 3 months following AMI (r = 0.66, p 0.0001). One-year survival in patients with Doppler index index > or = 0......, we conclude that the Doppler echocardiographic myocardial performance index is a predictor of LV dilation and cardiac death after a first AMI....

  16. Myocardial response to a triathlon in male athletes evaluated by Doppler tissue imaging and biochemical parameters

    DEFF Research Database (Denmark)

    Leetmaa, T H; Dam, A; Glintborg, D

    2008-01-01

    (cTnT) and pro-brain natriuretic peptide (pro-BNP)] and echocardiography. Conventional echocardiography techniques and new Doppler tissue imaging (DTI) modalities were applied before and immediately after the competition. Blood samples were drawn 1 week before, immediately after and 12-24 h post...... and systolic velocities decreased, thus suggesting reversible cardiac fatigue. When using cardiac markers and echocardiographic findings, a triathlon was found to have no significant negative effects on left ventricular function or myocardial tissue in male athletes....

  17. The modern role of transoesophageal echocardiography in the assessment of valvular pathologies

    Science.gov (United States)

    Bull, Sacha; Newton, James

    2017-01-01

    Despite significant advancements in the field of cardiovascular imaging, transoesophageal echocardiography remains the key imaging modality in the management of valvular pathologies. This paper provides echocardiographers with an overview of the modern role of TOE in the diagnosis and management of valvular disease. We describe how the introduction of 3D techniques has changed the detection and grading of valvular pathologies and concentrate on its role as a monitoring tool in interventional cardiology. In addition, we focus on the echocardiographic and Doppler techniques used in the assessment of prosthetic valves and provide guidance for the evaluation of prosthetic valves. Finally, we summarise quantitative methods used for the assessment of valvular stenosis and regurgitation and highlight the key areas where echocardiography remains superior over other novel imaging modalities. PMID:28096184

  18. The modern role of transoesophageal echocardiography in the assessment of valvular pathologies

    Directory of Open Access Journals (Sweden)

    Malgorzata Wamil MD PhD

    2017-03-01

    Full Text Available Despite significant advancements in the field of cardiovascular imaging, transoesophageal echocardiography remains the key imaging modality in the management of valvular pathologies. This paper provides echocardiographers with an overview of the modern role of TOE in the diagnosis and management of valvular disease. We describe how the introduction of 3D techniques has changed the detection and grading of valvular pathologies and concentrate on its role as a monitoring tool in interventional cardiology. In addition, we focus on the echocardiographic and Doppler techniques used in the assessment of prosthetic valves and provide guidance for the evaluation of prosthetic valves. Finally, we summarise quantitative methods used for the assessment of valvular stenosis and regurgitation and highlight the key areas where echocardiography remains superior over other novel imaging modalities.

  19. Power Doppler Ultrasonography and Shear Wave Elastography as Complementary Imaging Methods for Suspected Local Breast Cancer Recurrence.

    Science.gov (United States)

    Jales, Rodrigo Menezes; Dória, Maira Teixeira; Serra, Kátia Piton; Miranda, Mila Meneguelli; Menossi, Carlos Alberto; Schumacher, Klaus; Sarian, Luis Otávio

    2018-06-01

    To prospectively investigate the diagnostic accuracy and clinical consequences of power Doppler morphologic criteria and shear wave elastography (SWE) as complementary imaging methods for evaluation of suspected local breast cancer recurrence in the ipsilateral breast or chest wall. Thirty-two breast masses with a suspicion of local breast cancer recurrence on B-mode ultrasonography underwent complementary power Doppler and SWE evaluations. Power Doppler morphologic criteria were classified as avascular, hypovascular, or hypervascular. Shear wave elastography was classified according to a 5-point scale (SWE score) and SWE maximum elasticity. Diagnostic accuracy was assessed by the sensitivity, specificity, and area under the curve. A decision curve analysis assessed clinical consequences of each method. The reference standard for diagnosis was defined as core needle or excisional biopsy. Histopathologic examinations revealed 9 (28.2%) benign and 23 (71.8%) malignant cases. Power Doppler ultrasonography (US) had sensitivity of 34.8% (95% confidence interval [CI], 6.6%-62.9%) and specificity of 45.4% (95% CI, 19.3%-71.5%). The SWE score (≥3) had sensitivity of 87.0% (95% CI, 66.4%-97.2%) and specificity of 44.4% (95% CI, 13.7%-78.8%). The SWE maximum elasticity (velocity > 6.5cm/s) had sensitivity of 87% (95% CI, 66.4%-97.2%) and specificity of 77.8% (95% CI, 40.0% to 97.2%). The areas under the curves for the SWE score and SWE maximum elasticity were 0.71 (95% CI, 0.53-0.87) and 0.82 (95% CI, 0.64-0.93), respectively (P = .32). Power Doppler US is unsuitable for discrimination between local breast cancer recurrence and fibrosis. Although the SWE score and SWE maximum elasticity can make this discrimination, the use of these methods to determine biopsy may lead to poorer clinical outcomes than the current practice of performing biopsies of all suspicious masses. © 2017 by the American Institute of Ultrasound in Medicine.

  20. Cardiac Time Intervals Measured by Tissue Doppler Imaging M-mode

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor; Møgelvang, Rasmus; Schnohr, Peter

    2016-01-01

    function was evaluated in 1915 participants by using both conventional echocardiography and tissue Doppler imaging (TDI). The cardiac time intervals, including the isovolumic relaxation time (IVRT), isovolumic contraction time (IVCT), and ejection time (ET), were obtained by TDI M-mode through the mitral......). Additionally, they displayed a significant dose-response relationship, between increasing severity of elevated blood pressure and increasing left ventricular mass index (P

  1. Theoretical and experimental signal-to-noise ratio assessment in new direction sensing continuous-wave Doppler lidar

    DEFF Research Database (Denmark)

    Pedersen, Anders Tegtmeier; Foroughi Abari, Farzad; Mann, Jakob

    2014-01-01

    A new direction sensing continuous-wave Doppler lidar based on an image-reject homodyne receiver has recently been demonstrated at DTU Wind Energy, Technical University of Denmark. In this contribution we analyse the signal-to-noise ratio resulting from two different data processing methods both...... leading to the direction sensing capability. It is found that using the auto spectrum of the complex signal to determine the wind speed leads to a signal-to-noise ratio equivalent to that of a standard self-heterodyne receiver. Using the imaginary part of the cross spectrum to estimate the Doppler shift...... has the benefit of a zero-mean background spectrum, but comes at the expense of a decrease in the signal-to noise ratio by a factor of √2....

  2. Early detection of myocardial dysfunction using two-dimensional speckle tracking echocardiography in a young cat with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Ryohei Suzuki

    2018-02-01

    Full Text Available Case summary A 5-month-old intact female Scottish Fold cat was presented for cardiac evaluation. Careful auscultation detected a slight systolic murmur (Levine I/VI. The findings of electrocardiography, thoracic radiography, non-invasive blood pressure measurements and conventional echocardiographic studies were unremarkable. However, two-dimensional speckle tracking echocardiography revealed abnormalities in myocardial deformations, including decreased early-to-late diastolic strain rate ratios in longitudinal, radial and circumferential directions, and deteriorated segmental systolic longitudinal strain. At the follow-up examinations, the cat exhibited echocardiographic left ventricular hypertrophy and was diagnosed with hypertrophic cardiomyopathy using conventional echocardiography. Relevance and novel information This is the first report on the use of two-dimensional speckle tracking echocardiography for the early detection of myocardial dysfunction in a cat with hypertrophic cardiomyopathy; the myocardial dysfunction was detected before the development of hypertrophy. The findings from this case suggest that two-dimensional speckle tracking echocardiography can be useful for myocardial assessment when conventional echocardiographic and Doppler findings are ambiguous.

  3. Tissue Doppler echocardiography reveals impaired cardiac function in patients with reversible ischaemia

    DEFF Research Database (Denmark)

    Hoffmann, Søren; Mogelvang, Rasmus; Sogaard, Peter

    2011-01-01

    AIMS: To determine if echocardiographic tissue Doppler imaging (TDI) performed at rest detects reduced myocardial function in patients with reversible ischaemia. METHODS AND RESULTS: Eighty-four patients with angina pectoris, no previous history of ischaemic heart disease and normal left ventricu...

  4. [Estimation of the atrioventricular time interval by pulse Doppler in the normal fetal heart].

    Science.gov (United States)

    Hamela-Olkowska, Anita; Dangel, Joanna

    2009-08-01

    To assess normative values of the fetal atrioventricular (AV) time interval by pulse-wave Doppler methods on 5-chamber view. Fetal echocardiography exams were performed using Acuson Sequoia 512 in 140 singleton fetuses at 18 to 40 weeks of gestation with sinus rhythm and normal cardiac and extracardiac anatomy. Pulsed Doppler derived AV intervals were measured from left ventricular inflow/outflow view using transabdominal convex 3.5-6 MHz probe. The values of AV time interval ranged from 100 to 150 ms (mean 123 +/- 11.2). The AV interval was negatively correlated with the heart rhythm (page of gestation (p=0.007). However, in the same subgroup of the fetal heart rate there was no relation between AV intervals and gestational age. Therefore, the AV intervals showed only the heart rate dependence. The 95th percentiles of AV intervals according to FHR ranged from 135 to 148 ms. 1. The AV interval duration was negatively correlated with the heart rhythm. 2. Measurement of AV time interval is easy to perform and has a good reproducibility. It may be used for the fetal heart block screening in anti-Ro and anti-La positive pregnancies. 3. Normative values established in the study may help obstetricians in assessing fetal abnormalities of the AV conduction.

  5. Prenatal color Doppler ultrasonographic diagnosis of fetal tetralogy of Fallot

    International Nuclear Information System (INIS)

    Tan Buqiao

    2009-01-01

    Objective: To investigate the sonographic findings of tetralogy of Fallot in fetuses. Methods: The data of color Doppler ultrasonography and follow-up results of 5 fetal tetralogy of Fallot were analyzed retrospectively, and their abnormal ultrasound imaging characteristic were summarized. Results: Two cases were proved tetralogy of Fallot by autopsy, and three cases were confirmed to be tetralogy of Fallot by echocardiography after birth. The image features were the main aorta situated above the ventricular septal defect, pulmonary stenosis, no obvious thickening of the right wall. Conclusion: Fetal tetralogy of Fallot have characteristic ultrasound images, prenatal color Doppler ultrasonographic can diagnoses fetal tetralogy of Fallot correctly and has important clinical value. (authors)

  6. Spectral Doppler interrogation of the patent foramen ovale-a window to left heart hemodynamics.

    Science.gov (United States)

    Fadel, Bahaa M; Husain, Aysha; Bakarman, Hatem; Dahdouh, Ziad; Salvo, Giovanni Di; Mohty, Dania

    2015-02-01

    Spectral Doppler interrogation of flow across a patent foramen ovale (PFO) allows recording of the instantaneous pressure gradient between left and right atrium (RA). The assessment of RA pressure using the size and collapsibility of the inferior vena cava would thus allow estimation of left atrial (LA) pressure. In this article, we illustrate the value of spectral Doppler interrogation of flow across the PFO by transthoracic echocardiography as a novel and simple tool for the assessment of LA pressure and left cardiac hemodynamics in addition to the conventional noninvasive parameters. © 2014, Wiley Periodicals, Inc.

  7. The association between brain natriuretic peptide and tissue Doppler parameters in children with hypertrophic cardiomyopathy

    Directory of Open Access Journals (Sweden)

    Taliha Öner

    2016-01-01

    Full Text Available In this study, we investigated the association between brain natriuretic peptide (BNP levels and tissue Doppler imaging measurements and also screening for deadly mutations in patients with hypertrophic cardiomyopathy (HCM. We enrolled 20 patients diagnosed with HCM (age:10.7±5 years (1-17, 85% male, weight:42.25±23.10 kg, height:141.80±32.45 cm and 20 age, gender and body weight-matched control subjects. We performed electrocardiography, transthoracic echocardiography, and tissue Doppler echocardiography in each group, as well as genetic tests (for Arg403Gln, Arg453Cys, Arg719Trp and Arg719Gln mutations in MYH7 Exons 13, 14, 19 and BNP in the patients. The patients were divided into two groups according to the presence (Group 1 or absence (Group 2 of left ventricular (LV outflow tract obstruction. QTc dispersion and the LV ejection fraction and left atrial (LA volume index were increased in Group 1. The LA volume index and the mitral and septal E/Ea ratio and septum Z-score were increased while the mitral lateral annulus and septal annulus Ea wave velocities and the mitral and tricuspid E/A ratio were decreased in patients with high levels of BNP compared to those with normal BNP levels. There were no mutations that are associated with increased risk of sudden death found in patients included in this study. In the light of our data, we conclude that such parameters BNP levels above the 98 pg/mL, septal thickness Z-score ˃6, and higher mitral and septal E/Ea ratios can be used for management of patients with HCM according to life-threatening conditions.

  8. Three-dimensional transesophageal echocardiography: Principles and clinical applications

    Directory of Open Access Journals (Sweden)

    Annette Vegas

    2016-01-01

    Full Text Available A basic understanding of evolving 3D technology enables the echocardiographer to master the new skills necessary to acquire, manipulate, and interpret 3D datasets. Single button activation of specific 3D imaging modes for both TEE and transthoracic echocardiography (TTE matrix array probes include (a live, (b zoom, (c full volume (FV, and (d color Doppler FV. Evaluation of regional LV wall motion by RT 3D TEE is based on a change in LV chamber subvolume over time from altered segmental myocardial contractility. Unlike standard 2D TEE, there is no direct measurement of myocardial thickening or displacement of individual segments.

  9. Invasive and noninvasive assessment of pulmonic regurgitation: clinical, angiographic, phonocardiographic, echocardiographic, and Doppler ultrasound correlations.

    Science.gov (United States)

    Chandraratna, P A; Wilson, D; Imaizumi, T; Ritter, W S; Aronow, W S

    1982-06-01

    Three patients with pulmonic regurgitation and no evidence of pulmonary hypertension were investigated. These patients had low pitched diastolic murmurs which increased on inspiration, evidence of connective tissue disease as manifested by lax joints and hyperextensible skin, and marked hilar dance which extended up to the peripheral vessels. Suprasternal echocardiography revealed dilatation and increased systolic expansion of the right pulmonary artery (RPA) (25% and 28%, respectively) in two patients; the third patient had a normal RPA dimension in diastole and a marked increase in diameter (88%) in systole. Thus, these three patients demonstrated hyperdistensibility of the RPA. The spectral signal from the pulsed doppler echocardiograph showed evidence of turbulent blood flow in diastole (wide dispersion of the dots) in the right ventricular outflow tract in all three patients. This pattern was indicative of pulmonic regurgitation. In summary, the combined use of echocardiography and Doppler ultrasound is useful in the evaluation of patients with pulmonic regurgitation.

  10. Incremental value of contrast echocardiography in the evaluation of a cardiac thrombus.

    Science.gov (United States)

    Po, Jose Ricardo F; Tong, Matthew S; Grove, Erica L; Biederman, Robert W W

    2017-02-01

    A 52-year-old man presented with altered mental status and report of prior complaint of chest pain. On electrocardiography, anterolateral ST-segment elevations with Q-waves in the septal leads were seen. Initial echocardiography images demonstrated a thickened anteroseptum. Further imaging showed the presence of a well-attached laminated apical thrombus. Contrast echocardiography images showed that the thrombus had minimal attachment to the endocardial surface. CT head subsequently showed the presence of acute stroke. The case demonstrates the additional value of contrast echocardiography in the evaluation of cardiac masses despite the certainty in the diagnosis of a thrombus. © 2017, Wiley Periodicals, Inc.

  11. Comparing Methods for Cardiac Output: Intraoperatively Doppler-Derived Cardiac Output Measured With 3-Dimensional Echocardiography Is Not Interchangeable With Cardiac Output by Pulmonary Catheter Thermodilution.

    Science.gov (United States)

    Graeser, Karin; Zemtsovski, Mikhail; Kofoed, Klaus F; Winther-Jensen, Matilde; Nilsson, Jens C; Kjaergaard, Jesper; Møller-Sørensen, Hasse

    2018-01-09

    Estimation of cardiac output (CO) is essential in the treatment of circulatory unstable patients. CO measured by pulmonary artery catheter thermodilution is considered the gold standard but carries a small risk of severe complications. Stroke volume and CO can be measured by transesophageal echocardiography (TEE), which is widely used during cardiac surgery. We hypothesized that Doppler-derived CO by 3-dimensional (3D) TEE would agree well with CO measured with pulmonary artery catheter thermodilution as a reference method based on accurate measurements of the cross-sectional area of the left ventricular outflow tract. The primary aim was a systematic comparison of CO with Doppler-derived 3D TEE and CO by thermodilution in a broad population of patients undergoing cardiac surgery. A subanalysis was performed comparing cross-sectional area by TEE with cardiac computed tomography (CT) angiography. Sixty-two patients, scheduled for elective heart surgery, were included; 1 was subsequently excluded for logistic reasons. Inclusion criteria were coronary artery bypass surgery (N = 42) and aortic valve replacement (N = 19). Exclusion criteria were chronic atrial fibrillation, left ventricular ejection fraction below 0.40 and intracardiac shunts. Nineteen randomly selected patients had a cardiac CT the day before surgery. All images were stored for blinded post hoc analyses, and Bland-Altman plots were used to assess agreement between measurement methods, defined as the bias (mean difference between methods), limits of agreement (equal to bias ± 2 standard deviations of the bias), and percentage error (limits of agreement divided by the mean of the 2 methods). Precision was determined for the individual methods (equal to 2 standard deviations of the bias between replicate measurements) to determine the acceptable limits of agreement. We found a good precision for Doppler-derived CO measured by 3D TEE, but although the bias for Doppler-derived CO by 3D compared to

  12. Predicting Paroxysmal Atrial Fibrillation in Cerebrovascular Ischemia Using Tissue Doppler Imaging and Speckle Tracking Echocardiography

    DEFF Research Database (Denmark)

    Olsen, Flemming Javier; Jørgensen, Peter Godsk; Møgelvang, Rasmus

    2016-01-01

    BACKGROUND: Often the underlying cause of cerebral ischemia (CI) cannot be found during a routine diagnostic investigation, but paroxysmal atrial fibrillation (PAF) could be the culprit. AIM: The objective of the study is to investigate whether advanced echocardiography improves the diagnostic ap...

  13. Cardiac time intervals by tissue Doppler imaging M-mode echocardiography

    DEFF Research Database (Denmark)

    Biering-Sørensen, Tor

    2016-01-01

    for myocardial myocytes to achieve an LV pressure equal to that of aorta increases, resulting in a prolongation of the isovolumic contraction time (IVCT). Furthermore, the ability of myocardial myocytes to maintain the LV pressure decreases, resulting in reduction in the ejection time (ET). As LV diastolic...... of whether the LV is suffering from impaired systolic or diastolic function. A novel method of evaluating the cardiac time intervals has recently evolved. Using tissue Doppler imaging (TDI) M-mode through the mitral valve (MV) to estimate the cardiac time intervals may be an improved method reflecting global...

  14. Changes in Speckle Tracking Echocardiography Measures of Ventricular Function after Percutaneous Implantation of the Edwards SAPIEN Transcatheter Heart Valve in the Pulmonary Position

    Science.gov (United States)

    Chowdhury, Shahryar M.; Hijazi, Ziyad M.; Rhodes, John F.; Kar, Saibal; Makkar, Raj; Mullen, Michael; Cao, Qi-Ling; Mandinov, Lazar; Buckley, Jason; Pietris, Nicholas P.; Shirali, Girish S.

    2015-01-01

    Background Patients with free pulmonary regurgitation or mixed pulmonary stenosis and regurgitation and severely dilated right ventricles (RV) show little improvement in ventricular function after pulmonary valve replacement when assessed by traditional echocardiographic markers. We evaluated changes in right and left ventricular (LV) function using speckle tracking echocardiography in patients after SAPIEN transcatheter pulmonary valve (TPV) placement. Methods Echocardiograms were evaluated at baseline, discharge, 1 and 6 months after TPV placement in 24 patients from 4 centers. Speckle tracking measures of function included peak longitudinal strain, strain rate, and early diastolic strain rate. RV fractional area change, tricuspid annular plane systolic excursion, and left ventricular LV ejection fraction were assessed. Routine Doppler and tissue Doppler velocities were measured. Results At baseline, all patients demonstrated moderate to severe pulmonary regurgitation; this improved following TPV placement. No significant changes were detected in conventional measures of RV or LV function at 6 months. RV longitudinal strain (−16.9% vs. −19.6%, P echocardiography may be more sensitive than traditional measures in detecting changes in systolic function after TPV implantation. (Echocardiography 2015;32:461–469) PMID:25047063

  15. What Is Echocardiography?

    Science.gov (United States)

    ... Intramural Research Home / Echocardiography Echocardiography Also known as Echo , Surface echo , Ultrasound of ... other tests, echo doesn't involve radiation. Transthoracic Echocardiography Transthoracic (tranz-thor-AS-ik) echo is the ...

  16. The importance of echocardiography in diagnostics of idiopathic pulmonary arterial hypertension: A case report

    Directory of Open Access Journals (Sweden)

    Stojković Gabrijela

    2011-01-01

    Full Text Available Introduction. Idiopathic pulmonary arterial hypertension (IPAH is rare and difficult progressive disease with prevalence of approximately 15 cases per million residents, with predominant female cases. Case Outline. A 47-year-old female presented with symptoms and signs of the right heart chambers failure. Over prior seven years the patient had the feeling of suffocation and fatigue when walking, and received treatment for bronchial asthma. Physical examination revealed a marked loud second heart sound over the pulmonary artery. Electrocardiogram: right ventricular hypertrophy. Spirometric (pulmonary capacity test, cardiac perfusion scan and spiral CT scanning excluded secondary pulmonary arterial hypertension. Blood testing for connective tissue diseases and HIV were within normal reference limits. Transthoracic colour Doppler echocardiography demonstrated a mild tricuspid regurgitation with high values of estimated maximal and middle systolic pressure of the right ventricle (135/110 mm Hg, and excluded previous heart disease. Cardiac catheterization confirmed IPAH diagnosis, with systolic right ventricular pressure of 101/47/66 mm Hg and pulmonary capillary pressure of 30/13/10 mm Hg. Basic therapy with sildenafil, nevertheless, considerable limitations of strain tolerance was still present. Conclusion. IPAH is a severe heart disease with non-specific signs and symptoms. Screening for IPAH is transthoracic colour Doppler echocardiography shows high correlation with cardiac catheterization.

  17. Retinopathy is associated with impaired myocardial function assessed by advanced echocardiography in type 1 diabetes patients – The Thousand & 1 Study

    DEFF Research Database (Denmark)

    Nouhravesh, Nina; Andersen, Henrik U; Jensen, Jan S

    2016-01-01

    AIMS: Retinopathy and heart disease in Type 1 Diabetes Mellitus (Type 1 DM) may be associated; however previous results have been conflicting. Tissue Doppler Imaging (TDI) and speckle-tracking echocardiography (STE) quantify myocardial function not assessable by conventional echocardiography. We...... investigated the association between severity of retinopathy and early myocardial dysfunction using conventional echocardiography, TDI and STE in Type 1 DM patients. METHODS: Type 1 Diabetes Mellitus patients without known heart disease were included from the Steno Diabetes Center. The cross sectional...... association between retinopathy and myocardial function was analyzed in uni-and multivariable models. Retinopathy was categorized as nil-, simplex- or proliferative retinopathy. RESULTS: A total of 1090 Type 1 Diabetes Mellitus patients were included, mean age was 49.6years and 53% were males. Left...

  18. OPPORTUNITIES OF TRANSVAGINAL ECHOCARDIOGRAPHY FOR EARLY PRENATAL DIAGNOSIS OF INBORN HEART DISEASES IN FETUS

    Directory of Open Access Journals (Sweden)

    E.A. Shevchenko

    2008-01-01

    Full Text Available According to the literature data, transvaginal echocardiography (Echocg is the method, used for the doppler diagnostics in early terms of pregnancy (if principles of safety are observed. This method allows detecting about 70–97% of all prognostic cally significant inborn heart diseases in fetus, beginning at 12 week of pregnancy. a scheme of research includes estimation of four chamber cut of fetus heart, and study of state of its main arteries. This is an expert investigation, because it needs special grounding of specialist, high resolution ultrasonic equipment, and considerable expense of time. Wile parameters are estimated, it is necessary to use normative rates of sizes of ventricles and main arteries of fetus, developed by Russian experts, taking into account individual variations.Key words: transvaginal echocardiography, diagnosis, inborn heart disease.

  19. Role of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation in detecting fetal pulmonary veins.

    Science.gov (United States)

    Sun, Xue; Zhang, Ying; Fan, Miao; Wang, Yu; Wang, Meilian; Siddiqui, Faiza Amber; Sun, Wei; Sun, Feifei; Zhang, Dongyu; Lei, Wenjia; Hu, Guyue

    2017-06-01

    Prenatal diagnosis of fetal total anomalous pulmonary vein connection (TAPVC) remains challenging for most screening sonographers. The purpose of this study was to evaluate the use of four-dimensional echocardiography with high-definition flow imaging and spatiotemporal image correlation (4D-HDFI) in identifying pulmonary veins in normal and TAPVC fetuses. We retrospectively reviewed and performed 4D-HDFI in 204 normal and 12 fetuses with confirmed diagnosis of TAPVC. Cardiac volumes were available for postanalysis to obtain 4D-rendered images of the pulmonary veins. For the normal fetuses, two other traditional modalities including color Doppler and HDFI were used to detect the number of pulmonary veins and comparisons were made between each of these traditional methods and 4D-HDFI. For conventional echocardiography, HDFI modality was superior to color Doppler in detecting more pulmonary veins in normal fetuses throughout the gestational period. 4D-HDFI was the best method during the second trimester of pregnancy in identifying normal fetal pulmonary veins. 4D-HDFI images vividly depicted the figure, course, and drainage of pulmonary veins in both normal and TAPVC fetuses. HDFI and the advanced 4D-HDFI technique could facilitate identification of the anatomical features of pulmonary veins in both normal and TAPVC fetuses; 4D-HDFI therefore provides additional and more precise information than conventional echocardiography techniques. © 2017, Wiley Periodicals, Inc.

  20. Applications of doppler effect in navigation and oceanography

    Digital Repository Service at National Institute of Oceanography (India)

    Joseph, A.

    The Doppler effect is the change in frequency of the received sound waves/electromagnetic waves when there is a relative motion between the transmitter and the receiver of these waves. This effect is used for diverse applications in different areas...

  1. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    OpenAIRE

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in f...

  2. Digital storage and analysis of color Doppler echocardiograms

    Science.gov (United States)

    Chandra, S.; Thomas, J. D.

    1997-01-01

    Color Doppler flow mapping has played an important role in clinical echocardiography. Most of the clinical work, however, has been primarily qualitative. Although qualitative information is very valuable, there is considerable quantitative information stored within the velocity map that has not been extensively exploited so far. Recently, many researchers have shown interest in using the encoded velocities to address the clinical problems such as quantification of valvular regurgitation, calculation of cardiac output, and characterization of ventricular filling. In this article, we review some basic physics and engineering aspects of color Doppler echocardiography, as well as drawbacks of trying to retrieve velocities from video tape data. Digital storage, which plays a critical role in performing quantitative analysis, is discussed in some detail with special attention to velocity encoding in DICOM 3.0 (medical image storage standard) and the use of digital compression. Lossy compression can considerably reduce file size with minimal loss of information (mostly redundant); this is critical for digital storage because of the enormous amount of data generated (a 10 minute study could require 18 Gigabytes of storage capacity). Lossy JPEG compression and its impact on quantitative analysis has been studied, showing that images compressed at 27:1 using the JPEG algorithm compares favorably with directly digitized video images, the current goldstandard. Some potential applications of these velocities in analyzing the proximal convergence zones, mitral inflow, and some areas of future development are also discussed in the article.

  3. Feasibility of transesophageal echocardiography in birds without cardiac disease.

    Science.gov (United States)

    Beaufrère, Hugues; Pariaut, Romain; Nevarez, Javier G; Tully, Thomas N

    2010-03-01

    To establish a technique of transesophageal echocardiography (TEE) in birds without cardiac disease and describe the imaging planes obtained. Validation study. 18 birds including 3 pigeons (Columbia livia), 3 barred owls (Strix varia), 2 red-tailed hawks (Buteo jamaicensis), 1 goose (Anser anser), 1 mallard duck (Anas platyrhynchos), 1 Muscovy duck (Cairina moschata), 2 brown pelicans (Pelecanus occidentalis), 2 Hispaniolan Amazon parrots (Amazona ventralis), 2 red-fronted macaws (Ara rubrogenys), and 1 military macaw (Ara militaris). For each bird, anesthesia was induced and maintained by use of isoflurane. A pediatric, multiplane transesophageal ultrasound probe was passed into the esophagus and adjusted to the level of the heart for echocardiography. Probe positions were recorded via fluoroscopy, and associated imaging planes were described. TEE was performed successfully in all birds except the pelicans, 1 Hispaniolan Amazon parrot, and the red-fronted macaws. Five imaging planes of the heart were consistently viewed from 3 positions of the probe (identified as caudal, middle, and cranial positions relative to the cardiac silhouette). M-mode echocardiography of the left ventricle and the aortic root was performed. Color flow and spectral Doppler ultrasonographic images of in- and outflow regions were obtained. One Hispaniolan Amazon parrot died as a result of esophageal perforation. TEE examination of birds was feasible and provided a larger number of imaging planes with better resolution and details than those typically achieved via a transcoelomic approach. However, TEE should be performed with caution in psittacines.

  4. Doppler radar physiological sensing

    CERN Document Server

    Lubecke, Victor M; Droitcour, Amy D; Park, Byung-Kwon; Singh, Aditya

    2016-01-01

    Presents a comprehensive description of the theory and practical implementation of Doppler radar-based physiological monitoring. This book includes an overview of current physiological monitoring techniques and explains the fundamental technology used in remote non-contact monitoring methods. Basic radio wave propagation and radar principles are introduced along with the fundamentals of physiological motion and measurement. Specific design and implementation considerations for physiological monitoring radar systems are then discussed in detail. The authors address current research and commercial development of Doppler radar based physiological monitoring for healthcare and other applications.

  5. Preliminary simulation study of doppler reflectometry

    International Nuclear Information System (INIS)

    Ishii, Yuta; Hojo, Hitoshi; Yoshikawa, Masashi; Ichimura, Makoto; Haraguchi, Yusuke; Imai, Tsuyoshi; Mase, Atsushi

    2010-01-01

    A preliminary simulation study of Doppler reflectometry is performed. The simulations solve Maxwell's equations by a finite difference time domain (FDTD) code method in two dimensions. A moving corrugated metal target is used as a plasma cutoff layer to study the basic features of Doppler reflectometry. We examined the effects of the full width at half maximum (FWHM) of the electromagnetic waves and the corrugation depth of the metal target. Furthermore, the effect of a nonuniform plasma is studied using this FDTD analysis. The Doppler shift and velocity are compared with those obtained from FDTD analysis of a uniform plasma. (author)

  6. (abstract) Spacecraft Doppler Tracking with the Deep Space Network in the Search for Gravitational Waves

    Science.gov (United States)

    Asmar, Sami; Renzetti, Nicholas

    1994-01-01

    The Deep Space Network generates accurate radio science data observables for investigators who use radio links between spacecraft and the Earth to examine small changes in the phase and/or amplitude of the signal to study a wide variety of structures and phenomena in space. Several such studies are directed at aspects of the theory of general relativity such as gravitational redshift and gravitational waves. A gravitational wave is a propagating, polarized gravitational field, a ripple in the curvature of space-time. In Einstein's theory of general relativity, the waves are propagating solutions of the Einstein field equations. Their amplitudes are dimensionless strain amplitudes that change the fractional difference in distance between test masses and the rates at which separated clocks keep time. Predicted by all relativistic theories of gravity, they are extremely weak (the ratio of gravitational forces to electrical forces is about 10(sup -40)) and are generated at detectable levels only by astrophysical sources - very massive sources under violent dynamical conditions. The waves have never been detected but searches in the low-frequency band using Doppler tracking of many spacecraft have been conducted and others are being planned. Upper limits have been placed on the gravitational wave strength with the best sensitivities to date are for periodic waves being 7 x 10(sup -15).

  7. Spectral pulsed-wave tissue Doppler imaging lateral-to-septal delay fails to predict clinical or echocardiographic outcome after cardiac resynchronization therapy

    NARCIS (Netherlands)

    O.I.I. Soliman (Osama Ibrahim Ibrahim); D.A.M.J. Theuns (Dominic); M.L. Geleijnse (Marcel); A. Nemes (Attila); K. Caliskan (Kadir); W.B. Vletter (Wim); L.J.L.M. Jordaens (Luc); F.J. ten Cate (Folkert)

    2007-01-01

    textabstractAims: The current study sought to assess if pre-implantation lateral-to-septal delay (LSD) ≥60 ms assessed by spectral pulsed-wave myocardial tissue Doppler imaging (PW-TDI) could predict successful long-term outcome after cardiac resynchronization therapy (CRT). Methods and results

  8. Doppler echocardiographic evaluation of HIV-positive patients in different stages of the disease

    Directory of Open Access Journals (Sweden)

    Werneck Guilherme Lobosco

    1999-01-01

    Full Text Available OBJETIVE: To evaluate by Doppler echocardiography (DE early abnormalities of ventricular function in HIV-positive patients, as well as other cardiac abnormalities that can be detected by this method, with special emphasis on mitral valve flow. METHODS: 84 HIV- positive patients, 59 with CD4 cell count >500/mm³ (Group A and 25 with CD4 cell count 500/mm³ had no abnormalities by DE. Patients with a more advanced infection (those with a CD4 cell count <500/mm³, had a significantly abnormal LV systolic function and a higher incidence of pericardial effusion and mitral regurgitation. Mitral valve inflow by Doppler did not indicate diastolic dysfunction.

  9. Radiotherapy-induced Early ECG Changes and Their Comparison with Echocardiography in Patients with Early-stage Breast Cancer.

    Science.gov (United States)

    Tuohinen, Suvi Sirkku; Keski-Pukkila, Konsta; Skyttä, Tanja; Huhtala, Heini; Virtanen, Vesa; Kellokumpu-Lehtinen, Pirkko-Liisa; Raatikainen, Pekka; Nikus, Kjell

    2018-04-01

    Early electrocardiogram (ECG) changes after breast cancer radiotherapy (RT) have been reported, but their characteristics and associated factors are largely unknown. This study aimed to explore early RT-induced ECG changes and to compare them with echocardiography changes. Sixty eligible patients with chemotherapy-naïve left-sided and 20 with right-sided breast cancer were evaluated with echocardiography, blood samples and ECG before and after RT. RT-induced ECG changes in the anterior leads. T-Wave changes were most frequent. T-Wave decline was associated independently with patient age (β=-0.245, p=0.005), mean heart radiation dose (β=1.252, p=0.001) and global systolic strain rate change (β=7.943, p=0.002). T-Wave inversion was associated independently with mean heart radiation dose (β=0.143, pECG changes were prevalent and associated with functional and structural changes in echocardiography. ECG could be used for post-RT cardiac screening. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  10. Preload dependence of color M-mode Doppler flow propagation velocity in controls and in patients with left ventricular dysfunction

    DEFF Research Database (Denmark)

    Møller, J E; Poulsen, S H; Søndergaard, E

    2000-01-01

    The purpose of this study was to assess the effects of preload alterations on color M-mode flow propagation velocity (Vp) in volunteers with normal left ventricular (LV) function and in patients with depressed LV function. Color M-mode Doppler echocardiography was performed during Valsalva maneuv...

  11. Transcranial Doppler and transesophageal echocardiography: comparison of both techniques and prospective clinical relevance of transcranial Doppler in patent foramen ovale detection.

    Science.gov (United States)

    Caputi, Luigi; Carriero, Maria Rita; Falcone, Chiara; Parati, Eugenio; Piotti, Patrizia; Materazzo, Carlo; Anzola, Gian Paolo

    2009-01-01

    Patent foramen ovale (PFO) has been investigated in several conditions apart from cryptogenic ischemic stroke. Contrast transesophageal echocardiography (cTEE) is the gold standard for the diagnosis, although it has some known limitations. Contrast transcranial Doppler (cTCD) allows a semiquantitative estimation of right-to-left shunt (RLS) volume. The aims of our study were to confirm the diagnostic accuracy of cTCD in PFO diagnosis and to compare the abilities of cTCD and cTEE to detect a RLS and PFO, respectively, under normal breathing. The latter could represent an important feature for its clinical significance. A total of 100 consecutive patients (59 women and 41 men, age 46 +/- 12 years) were evaluated after stabilized ischemic stroke/transient ischemic attack, migraine, and lacunae, and before neurosurgery in sitting position. All patients undertook cTEE and cTCD, at rest and under Valsalva maneuver (VM). cTEE under VM was the reference standard. A categorization of patients and a semiquantitative cTCD classification were proposed. In all, 63 of 100 patients had PFO diagnosed by cTEE. A general concordance of up to 90% between both techniques was found. cTCD sensitivity and specificity were 96.8% and 78.4%, respectively. In 17 of 100 patients with cTEE-proven PFO under VM, cTCD and cTEE detected RLS at rest in 75% (95% confidence interval [CI] 62%-85%) and 48% (95% CI 35%-61%) of cases, respectively (P < .001). cTEE disclosed RLS at rest in about 71% (95% CI 9%-42%) of cTCDs showing a "shower-curtain" pattern and only in about 22% (95% CI 52%-85%) of those cTCDs without that pattern. In diagnosing PFO, cTCD has a good accuracy compared with cTEE. To detect a RLS at rest, cTCD appears to be more sensitive than cTEE. The latter resulted positive under normal breathing, mostly in cases of significant RLS at cTCD. Our results point out the impact of cTCD in the evaluation of RLS volume, thus aiding, in association with the anatomic details by cTEE, in the

  12. DOPPLER SIGNATURES OF THE ATMOSPHERIC CIRCULATION ON HOT JUPITERS

    International Nuclear Information System (INIS)

    Showman, Adam P.; Lewis, Nikole K.; Fortney, Jonathan J.; Shabram, Megan

    2013-01-01

    The meteorology of hot Jupiters has been characterized primarily with thermal measurements, but recent observations suggest the possibility of directly detecting the winds by observing the Doppler shift of spectral lines seen during transit. Motivated by these observations, we show how Doppler measurements can place powerful constraints on the meteorology. We show that the atmospheric circulation—and Doppler signature—of hot Jupiters splits into two regimes. Under weak stellar insolation, the day-night thermal forcing generates fast zonal jet streams from the interaction of atmospheric waves with the mean flow. In this regime, air along the terminator (as seen during transit) flows toward Earth in some regions and away from Earth in others, leading to a Doppler signature exhibiting superposed blueshifted and redshifted components. Under intense stellar insolation, however, the strong thermal forcing damps these planetary-scale waves, inhibiting their ability to generate jets. Strong frictional drag likewise damps these waves and inhibits jet formation. As a result, this second regime exhibits a circulation dominated by high-altitude, day-to-night airflow, leading to a predominantly blueshifted Doppler signature during transit. We present state-of-the-art circulation models including non-gray radiative transfer to quantify this regime shift and the resulting Doppler signatures; these models suggest that cool planets like GJ 436b lie in the first regime, HD 189733b is transitional, while planets hotter than HD 209458b lie in the second regime. Moreover, we show how the amplitude of the Doppler shifts constrains the strength of frictional drag in the upper atmospheres of hot Jupiters. If due to winds, the ∼2 km s –1 blueshift inferred on HD 209458b may require drag time constants as short as 10 4 -10 6 s, possibly the result of Lorentz-force braking on this planet's hot dayside.

  13. On the influence of ocean waves on simulated GNSS-R delay-doppler maps

    Science.gov (United States)

    Clarizia, M. P.; di Bisceglie, M.; Galdi, C.; Gommenginger, C.; Srokosz, M.

    2012-04-01

    Global Navigation Satellite System-Reflectometry (GNSS-R), is an established technique that exploits GNSS signals of opportunity reflected from the surface of the ocean, to look primarily at the ocean surface roughness. The strength of this technique, and the primary motivation to carry it forward, is in the fact that GNSS signals are available globally, all the time and over the long term, and could help dramatically improve the monitoring of ocean wind and waves. GNSS-R offers the prospect of high density global measurements of directional sea surface roughness, which are essential for scientific purposes (i.e. quantifying the air-sea exchanges of gases), operational weather and ocean forecasting (i.e. prediction of high winds, dangerous sea states, risk of flooding and storm surges) and to support important climate-relevant Earth Observation techniques (IR SST, or surface salinity retrieval). The retrieval of ocean roughness from GNSS-R data has now been demonstrated with a reasonable level of accuracy from both airborne [1] and spaceborne [2] platforms. In both cases, Directional Mean Square Slopes (DMSS) of the ocean surface have been retrieved from GNSS-R data, in the form of Delay-Doppler Maps (DDMs), using an established theoretical scattering model by Zavorotny and Voronovich (Z-V) [3]. The need for a better assessment of the way the ocean waves influence the scattering of GPS signals has recently led to a different approach, consisting of simulating the scattering of such signals, using a more sophisticated large-scale scattering model than Z-V, and explicit simulations of realistic seas. Initial results produced from these simulations have been recently published in [4], where the emphasis has been put on the effects of different sea states on Radar Cross Section (RCS) and Polarization Ratio (PR) in space domain. Linear wind wave surfaces have been simulated using the Elfouhaily wind wave spectrum [5], for different wind speeds and directions, and with

  14. Material properties identification using ultrasonic waves and laser Doppler vibrometer measurements: a multi-input multi-output approach

    International Nuclear Information System (INIS)

    Longo, R; Vanlanduit, S; Guillaume, P

    2013-01-01

    In this paper a multi-input multi-output approach able to determine the material properties of homogeneous materials is presented. To do so, an experimental set-up which combines the use of multi harmonic signals with interleaved frequencies and laser Doppler vibrometer measurements has been developed. A modeling technique, based on transmission and reflection measurements, allowed the simultaneous determination of longitudinal wave velocity, density and thickness of the materials under test with high levels of precision and accuracy. (paper)

  15. Basic indications for the performance of Color Doppler echocardiography

    International Nuclear Information System (INIS)

    Manzur, Fernando; Olivo, Carlos

    2005-01-01

    Clinical practice based on evidence takes off emphasis in intuition; clinical experience and rational physiopathology give sufficient bases for the clinical decision assessment and emphasizes the evidence's examination for the clinical investigation. The comprehension of certain evidence rules is necessary for the correct interpretation of literature in respect to the causes, diagnostic tools and treatment strategies. The main aim of this research is to make a protocol for the indications of an echocardiogram in the clinical practice and to educate our country's general physicians in this conduct. The good practice is due to initiatives, activities and functional models that are in progress worldwide, as confirmed by evidence. Objective: echocardiography is actually the gold standard for the study of heart anatomy and physiology. Since its introduction in the clinical practice more than three decades ago, it has had such diffusion that it is considered an important tool in the cardiology assistance. It provides trustworthy functional anatomic information, as well as diagnosis and is decisive in the treatment and resolution of cardiovascular diseases. The progressive development of this technique has enabled its use in all the different fields that may affect the cardiovascular system. The objective is to help the clinical physicians in the making of decisions in concrete situations, guaranteeing them that the diagnosis is based on results given by valid scientific studies. In accordance to this, different studies as well as task force and management guides representative of the worldwide literature were compiled

  16. Study of the Myocardial Contraction and Relaxation Velocities through Doppler Tissue Imaging Echocardiography: A New Alternative in the Assessment of the Segmental Ventricular Function

    Directory of Open Access Journals (Sweden)

    Silva Carlos Eduardo Suaide

    2002-01-01

    Full Text Available OBJECTIVE: Doppler tissue imaging (DTI enables the study of the velocity of contraction and relaxation of myocardial segments. We established standards for the peak velocity of the different myocardial segments of the left ventricle in systole and diastole, and correlated them with the electrocardiogram. METHODS: We studied 35 healthy individuals (27 were male with ages ranging from 12 to 59 years (32.9 ± 10.6. Systolic and diastolic peak velocities were assessed by Doppler tissue imaging in 12 segments of the left ventricle, establishing their mean values and the temporal correlation with the cardiac cycle. RESULTS: The means (and standard deviation of the peak velocities in the basal, medial, and apical regions (of the septal, anterior, lateral, and posterior left ventricle walls were respectively, in cm/s, 7.35(1.64, 5.26(1.88, and 3.33(1.58 in systole and 10.56(2.34, 7.92(2.37, and 3.98(1.64 in diastole. The mean time in which systolic peak velocity was recorded was 131.59ms (±19.12ms, and diastolic was 459.18ms (±18.13ms based on the peak of the R wave of the electrocardiogram. CONCLUSION: In healthy individuals, maximum left ventricle segment velocities decreased from the bases to the ventricular apex, with certain proportionality between contraction and relaxation (P<0.05. The use of Doppler tissue imaging may be very helpful in detecting early alterations in ventricular contraction and relaxation.

  17. Trans-skull ultrasonic Doppler system aided by fuzzy logic

    Science.gov (United States)

    Hata, Yutaka; Nakamura, Masato; Yagi, Naomi; Ishikawa, Tomomoto

    2012-06-01

    This paper describes a trans-skull ultrasonic Doppler system for measuring the blood flow direction in brain under skull. In this system, we use an ultrasonic array probe with the center frequency of 1.0 MHz. The system determines the fuzzy degree of blood flow by Doppler Effect, thereby it locates blood vessel. This Doppler Effect is examined by the center of gravity shift of the frequency magnitudes. In in-vitro experiment, a cow bone was employed as the skull, and three silicon tubes were done as blood vessels, and bubble in water as blood. We received the ultrasonic waves through a protein, the skull and silicon tubes in order. In the system, fuzzy degrees are determined with respect to the Doppler shift, amplitude of the waves and attenuation of the tissues. The fuzzy degrees of bone and blood direction are calculated by them. The experimental results showed that the system successfully visualized the skull and flow direction, compared with the location and flow direction of the phantom. Thus, it detected the flow direction by Doppler Effect under skull, and automatically extracted the region of skull and blood vessel.

  18. Three-dimensional echocardiography

    International Nuclear Information System (INIS)

    Buck, Thomas

    2011-01-01

    Presents tips and tricks for beginners and experts Provides educational material for 3D training courses Features comprehensively illustrated cases Includes an accompanying DVD with video clips of all sample cases Three-dimensional echocardiography is the most recent fundamental advancement in echocardiography. Since real-time 3D echocardiography became commercially available in 2002, it has rapidly been accepted in echo labs worldwide. This book covers all clinically relevant aspects of this fascinating new technology, including a comprehensive explanation of its basic principles, practical aspects of clinical application, and detailed descriptions of specific uses in the broad spectrum of clinically important heart disease. The book was written by a group of well-recognized international experts in the field, who have not only been involved in the scientific and clinical evolution of 3D echocardiography since its inception but are also intensively involved in expert training courses. As a result, the clear focus of this book is on the practical application of 3D echocardiography in daily clinical routine with tips and tricks for both beginners and experts, accompanied by more than 150 case examples comprehensively illustrated in more than 800 images and more than 500 videos provided on a DVD. In addition to an in-depth review of the most recent literature on real-time 3D echocardiography, this book represents an invaluable reference work for beginners and expert users of 3D echocardiography. - Tips and tricks for beginners and experts - Educational material for 3D training courses - Comprehensively illustrated cases - DVD with video clips of all sample cases.

  19. Ultrasound Pulsed-Wave Doppler Detects an Intrathecal Location of an Epidural Catheter Tip: A Case Report.

    Science.gov (United States)

    Elsharkawy, Hesham; Saasouh, Wael; Patel, Bimal; Babazade, Rovnat

    2018-04-01

    Currently, no gold standard method exists for localization of an epidural catheter after placement. The technique described in this report uses pulsed-wave Doppler (PWD) ultrasound to identify intrathecal location of an epidural catheter. A thoracic epidural catheter was inserted after multiple trials with inconclusive aspiration and test dose. Ultrasound PWD confirmed no flow in the epidural space and positive flow in the intrathecal space. A fluid aspirate was positive for glucose, reconfirming intrathecal placement. PWD is a potential tool that can be used to locate the tip of an epidural catheter.

  20. Measurements of ultrasonic waves by means of laser Doppler velocimeter and an experimental study of elastic wave propagation in inhomogeneous media; Laser doppler sokudokei ni yoru choonpa keisoku to ganseki wo mochiita fukinshitsu baishitsu no hado denpa model jikken

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, O; Sato, T [Geological Survey of Japan, Tsukuba (Japan); Lei, X [Dia Consultants Company, Tokyo (Japan)

    1996-05-01

    In the study of seismic wave propagation, a model experimenting technique has been developed using a laser Doppler velocimeter (LDV) as the sensor. This technique, not dependent on conventional piezoelectric devices, only irradiates the specimen with laser to measure the velocity amplitude on the target surface, eliminating the need for close contact between the specimen and sensor. In the experiment, elastic penetration waves with their noise levels approximately 0.05mm/s were observed upon application of vibration of 10{sup 6}-10{sup 5}Hz. The specimen was stainless steel or rock, and waveforms caught by the LDV and piezoelectric device were compared. As the result, it was found that the LDV is a powerful tool for effectively explaining elastic wave propagation in inhomogeneous media. The piezoelectric device fails to reproduce accurately the waves to follow the initial one while the LDV detect the velocity amplitude on the specimen surface in a wide frequency range encouraging the discussion over the quantification of observed waveforms. 10 refs., 7 figs.

  1. Three-dimensional speckle tracking echocardiography allows detailed evaluation of left atrial function in hypertrophic cardiomyopathy--insights from the MAGYAR-Path Study.

    Science.gov (United States)

    Domsik, Péter; Kalapos, Anita; Chadaide, Számi; Sepp, Róbert; Hausinger, Péter; Forster, Tamás; Nemes, Attila

    2014-11-01

    Hypertrophic cardiomyopathy (HCM) represents a generalized myopathic process affecting both ventricular and atrial myocardium. Reduced left atrial (LA) function was demonstrated in HCM by different methods. Three-dimensional (3D) speckle tracking echocardiography (STE) has just been introduced for the evaluation of LA. This study was designed to compare 3DSTE-derived LA volumetric and strain parameters in HCM with healthy controls. The study comprised 23 consecutive HCM patients (mean age: 48.5 ± 15.1 years, 14 men). Their results were compared to 23 age- and gender-matched healthy controls. Complete two-dimensional Doppler echocardiography and 3DSTE have been performed in all cases. Calculated LA maximum (66.4 ± 20.4 mL vs. 36.0 ± 6.1 mL, P echocardiography allows detailed evaluation of LA (dys) function in HCM by volumetric and strain measurements. © 2014, Wiley Periodicals, Inc.

  2. Usefulness of hemodynamically distribution of intranodal vessels in differentiating metastatic neck lymph nodes-value of color doppler and spectral wave sonogram

    International Nuclear Information System (INIS)

    Mumtaz, U.

    2017-01-01

    Objective: To evaluate the diagnostic assessment of enlarged lymph nodes, based on its perfusion pattern by taking tissue diagnosis as gold standard. Study Design: Analytical study. Place and Duration of Study: Departments of Radiology and Pathology, PIMS Hospital, Islamabad, from February to May 2016. Methodology: Color sonography of patients with clinically, palpable cervical lymph nodes were carried by senior trainee under the supervision of senior radiologist. Ultrasound guided tissue diagnosis was obtained in all suspected malignant cases. Histopathology was taken as the gold standard for determining accuracy. Results: Accuracy, sensitivity and specificity, positive and negative predictive values of color Doppler ultrasound in detecting malignant cervical lymphadenopathy was found to be 88.46%, 86.05%, 79.31% and 92.50%, respectively with diagnostic accuracy of 86.95%, when intranodal vascular pattern on color Doppler imaging was analyzed. Using spectral wave indexes, the same values were 92.31%, 90.70%, 85.71%, 95.12%, respectively with overall diagnostic accuracy of 91.30%. Conclusion: Color Doppler sonography is much sensitive borderline than grey scale findings alone. Furthermore, lymph nodes appearing in the detection of malignant nodes on grey scale images can be reliably diagnosed on Doppler scan. (author)

  3. Coronary flow velocity reserve by echocardiography

    DEFF Research Database (Denmark)

    Olsen, Rasmus Huan; Pedersen, Lene Rørholm; Snoer, Martin

    2016-01-01

    BACKGROUND: Coronary flow velocity reserve (CFVR) measured by transthoracic Doppler echocardiography of the LAD is used to assess microvascular function but validation studies in clinical settings are lacking. We aimed to assess feasibility, reproducibility and agreement with myocardial flow...... performed within a week (1-week) and for all scans regardless of time gap (total) and to account for scar tissue for patients with and without previous myocardial infarction (MI). RESULTS: Eighty-six patients with median BMI 30.9 (IQR 29.4-32.9) kg × m(-2) and CFVR 2.29 (1.90-2.63) were included. CFVR...... was feasible in 83 (97 %) using a contrast agent in 14 %. For reproducibility overall (n = 21) limits of agreement (LOA) were (-0.75;0.71), within-subjects coefficient of variation (CV) 11 %, and reliability 0.84. For reproducibility within 1-week (n = 13) LOA were (-0.33;0.25), within-subjects CV 5...

  4. Feasibility of UltraFast Doppler in Post-operative Evaluation of Hepatic Artery in Recipients following Liver Transplantation.

    Science.gov (United States)

    Kim, Se-Young; Kim, Kyoung Won; Choi, Sang Hyun; Kwon, Jae Hyun; Song, Gi-Won; Kwon, Heon-Ju; Yun, Young Ju; Lee, Jeongjin; Lee, Sung-Gyu

    2017-11-01

    To determine the feasibility of using UltraFast Doppler in post-operative evaluation of the hepatic artery (HA) after liver transplantation (LT), we evaluated 283 simultaneous conventional and UltraFast Doppler sessions in 126 recipients over a 2-mo period after LT, using an Aixplorer scanner The Doppler indexes of the HA (peak systolic velocity [PSV], end-diastolic velocity [EDV], resistive index [RI] and systolic acceleration time [SAT]) by retrospective analysis of retrieved waves from UltraFast Doppler clips were compared with those obtained by conventional spectral Doppler. Correlation, performance in diagnosing the pathologic wave, examination time and reproducibility were evaluated. The PSV, EDV, RI and SAT of spectral and UltraFast Doppler measurements exhibited excellent correlation with favorable diagnostic performance. During the bedside examination, the mean time spent for UltraFast clip storing was significantly shorter than that for conventional Doppler US measurements. Both conventional and UltraFast Doppler exhibited good to excellent inter-analysis consistency. In conclusion, compared with conventional spectral Doppler, UltraFast Doppler values correlated excellently and yielded acceptable pathologic wave diagnostic performance with reduced examination time at the bedside and excellent reproducibility. Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  5. Doppler echocardiographic study in adolescents and young adults with sickle cell anemia

    Directory of Open Access Journals (Sweden)

    Wolney de Andrade Martins

    1999-12-01

    Full Text Available OBJECTIVE: Anatomical and functional assessment of the heart through Doppler and echocardiography in patients with cell anemia (SCA. METHODS: Twenty-five patients with SCA and ages ranging from 14 to 45 years were prospectively studied in a comparison with 25 healthy volunteers. All of them underwent clinical and laboratory evaluation and Doppler echocardiography as well.The measurements were converted into body surface indices. RESULTS: There were increases in all chamber diameters and left ventricle (LV mass of the SCA patients. It was characterised an eccentric hypertrophy of the left ventricle. The preload was increased (left ventricle end-diastolic volume and the afterload was decreased (diastolic blood pressure, peripheral vascular resistance and end-systolic parietal stress ESPS. The cardiac index was increased due to the stroke volume. The ejection fraction and the percentage of the systolic shortening , as well as the systolic time intervals of the LV were equivalent. The isovolumetric contraction period of the LV was increased. The mitral E-septum distance and the end-systolic volume index (ESVi were increased. The ESPS/ESVi ratio,a loading independent parameter, was decreased in SCA, suggesting systolic dysfunction. No significant differences in the diastolic function or in the pulmonary pressure occurred. CONCLUSION: Chamber dilations, eccentric hypertrophy and systolic dysfunction confirm the evidence of the literature in characterizing a sickle cell anemia cardiomyopathy.

  6. Physical model experiment for wave field measurements by means of laser Doppler vibrometer. Measurement of three components; Laser Doppler shindokei ni yoru butsuri model jikken. Hado sanseibun no kenshutsu

    Energy Technology Data Exchange (ETDEWEB)

    Nishizawa, O; Sato, T [Geological Survey of Japan, Tsukuba (Japan); Lei, X [DIA Consultant Co. Ltd., Tokyo (Japan)

    1997-05-27

    In this experiment, a beam incident from an oblique direction is reflected by a spherical lens toward the direction of incidence. When the surface of a matter is vibrated by elastic waves, the spherical lens comes into a translation motion that accompanies the vibration. It follows accordingly that the vibration on the surface of the matter may be detected by sensing the spherical lens travelling speed. Three components of the vibration may be determined if beams are focused at one spot from three directions. Detection of the S-wave component by LDV (laser Doppler vibrometer) discloses the complicated wave field in a heterogeneous material, and this physical model experiment may be utilized in various fields of study. For instance, information about problems that may surface in the field work may be collected beforehand in a physical model experiment for developing an S-wave-aided probing method. For the study of seismic wave propagation in a complicated three-dimensional ground structure, a numerical model is not enough, and a physical model experiment will be an effective method to fulfill the purpose. In the monitoring of cracks in a rock, again, not only elastic wave velocity but also waveform information collected from a physical model experiment should be fully utilized. 6 refs., 6 figs.

  7. Doppler Velocity Signatures of Idealized Elliptical Vortices

    Directory of Open Access Journals (Sweden)

    Wen-Chau Lee

    2006-01-01

    Full Text Available Doppler radar observations have revealed a class of atmospheric vortices (tropical cyclones, tornadoes, dust devils that possess elliptical radar reflectivity signatures. One famous example is Typhoon Herb (1996 that maintained its elliptical reflectivity structure over a 40-hour period. Theoretical work and dual-Doppler analyses of observed tropical cyclones have suggested two physical mechanisms that can explain the formation of two types of elliptical vortices observed in nature, namely, the combination of a circular vortex with either a wavenumber two vortex Rossby wave or a deformation field. The characteristics of these two types of elliptical vortices and their corresponding Doppler velocity signatures have not been previously examined.

  8. Left atrial strain: a new parameter for assessment of left ventricular filling pressure.

    Science.gov (United States)

    Cameli, Matteo; Mandoli, Giulia Elena; Loiacono, Ferdinando; Dini, Frank Lloyd; Henein, Michael; Mondillo, Sergio

    2016-01-01

    In order to obtain accurate diagnosis, treatment and prognostication in many cardiac conditions, there is a need for assessment of left ventricular (LV) filling pressure. While systole depends on ejection function of LV, diastole and its disturbances influence filling function and pressures. The commonest condition that represents the latter is heart failure with preserved ejection fraction in which LV ejection is maintained, but diastole is disturbed and hence filling pressures are raised. Significant diastolic dysfunction results in raised LV end-diastolic pressure, mean left atrial (LA) pressure and pulmonary capillary wedge pressure, all referred to as LV filling pressures. Left and right heart catheterization has traditionally been used as the gold standard investigation for assessing these pressures. More recently, Doppler echocardiography has taken over such application because of its noninvasive nature and for being patient friendly. A number of indices are used to achieve accurate assessment of filling pressures including: LV pulsed-wave filling velocities (E/A ratio, E wave deceleration time), pulmonary venous flow (S wave and D wave), tissue Doppler imaging (E' wave and E/E' ratio) and LA volume index. LA longitudinal strain derived from speckle tracking echocardiography (STE) is also sensitive in estimating intracavitary pressures. It is angle-independent, thus overcomes Doppler limitations and provides highly reproducible measures of LA deformation. This review examines the application of various Doppler echocardiographic techniques in assessing LV filling pressures, in particular the emerging role of STE in assessing LA pressures in various conditions, e.g., HF, arterial hypertension and atrial fibrillation.

  9. Left ventricular dysfunction in normotensive Type 1 diabetic patients: the impact of autonomic neuropathy

    DEFF Research Database (Denmark)

    Taskiran, M; Rasmussen, Verner; Rasmussen, Bo Valdemar

    2004-01-01

    systolic function was evaluated by cine magnetic resonance (MR) imaging. Results Doppler echocardiography showed a significant decrease in E/A ratio, i.e. the ratio between peak Early transmitral filling velocity during early diastole (E-wave) and peak transmitral Atrial filling velocity during late...... diastole (A-wave), in AN+ compared with C (P Cine MR imaging...

  10. Detection of gravitational radiation by the Doppler tracking of spacecraft

    International Nuclear Information System (INIS)

    Mashhoon, B.

    1979-01-01

    It has been suggested that the residual Doppler shift in the precision electromagnetic tracking of spacecraft be used to search for gravitational radiation that may be incident on the Earth-spacecraft system. The influence of a gravitational wave on the Doppler shift is calculated, and it is found that the residual shift is dominated by two terms: one is due to the passage of electromagnetic waves through the gravitational radiation field, and the other depends on the change in the relative velocity of the Earth and the spacecraft caused by the external wave. A detailed analysis is given of the influence of gravitational radiation on a binary system with an orbital size small compared to the wavelength of the incident radiation. It is shown that, as a consequence of the interaction with the external wave, the system makes a transition from one Keplerian orbit into another which, in general, has a different energy and angular momentum. It is therefore proposed to search for such effects in the solar system. Observations of the orbit of an artificial Earth satellite, the lunar orbit, and especially the planetary orbits offer exciting possibilities for the detection of gravitational waves of various wavelengths. From the results of the lunar laser ranging experiment and the range measurement to Mars, certain interesting limits may be established on the frequency of incidence of gravitational waves of a given flux on the Earth-Moon and the Earth-Mars systems. This is followed by a brief and preliminary analysis of the possibility of detecting gravitational radiation by measuring a residual secular Doppler shift in the satellite-to-satellite Doppler tracking of two counterorbiting drag-free spacecraft around the Earth as in the Van Patten-Everitt experiment

  11. Determinants of Pediatric Echocardiography Laboratory Productivity: Analysis from the Second Survey of the American Society of Echocardiography Committee on Echocardiography Laboratory Productivity.

    Science.gov (United States)

    Srivastava, Shubhika; Allada, Vivekanand; Younoszai, Adel; Lopez, Leo; Soriano, Brian D; Fleishman, Craig E; Van Hoever, Andrea M; Lai, Wyman W

    2016-10-01

    The American Society of Echocardiography Committee on Pediatric Echocardiography Laboratory Productivity aimed to study factors that could influence the clinical productivity of physicians and sonographers and assess longitudinal trends for the same. The first survey results indicated that productivity correlated with the total volume of echocardiograms. Survey questions were designed to assess productivity for (1) physician full-time equivalent (FTE) allocated to echocardiography reading (echocardiograms per physician FTE per day), (2) sonographer FTE (echocardiograms per sonographer FTE per year), and (3) machine utilization (echocardiograms per machine per year). Questions were also posed to assess work flow and workforce. For fiscal year 2013 or academic year 2012-2013, the mean number of total echocardiograms-including outreach, transthoracic, fetal, and transesophageal echocardiograms-per physician FTE per day was 14.3 ± 5.9, the mean number of echocardiograms per sonographer FTE per year was 1,056 ± 441, and the mean number of echocardiograms per machine per year was 778 ± 303. Both physician and sonographer productivity was higher at high-volume surgical centers and with echocardiography slots scheduled concordantly with clinic visits. Having an advanced imaging fellow and outpatient sedation correlated negatively with clinical laboratory productivity. Machine utilization was greater in laboratories with higher sonographer and physician productivity and lower for machines obtained before 2009. Measures of pediatric echocardiography laboratory staff productivity and machine utilization were shown to correlate positively with surgical volume, total echocardiography volumes, and concordant echocardiography scheduling; the same measures correlated negatively with having an advanced imaging fellow and outpatient sedation. There has been no significant change in staff productivity noted over two Committee on Pediatric Echocardiography Laboratory

  12. Relaxation and filling of the left ventricle assessed by Doppler echocardiography

    International Nuclear Information System (INIS)

    Myreng, Y.

    1990-01-01

    In patients with coronary disease the Doppler method described in the present work was capable of detecting a delayed left ventricular (LV) relaxation and a shift of LV filling from early towards late diastole. This might reflect changes in LV diastolic function due to myocardial ischemia. Furthermore, the method allowed monitoring of changes during treatment with atenolol and verapamil. These changes indicated that atenolol and verapamil were able to partially correct the relaxation abnormailty and increase the relative contribution of early diastolic filling. Although all the numerous variables that influence LV transmitral filling could be controlled in this noninvasive clinical study, the results suggest that antianginal drugs may have beneficial effect on diastolic function in coronary disease. 62 refs., 3 figs., 4 tabs

  13. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young [Dept. of Radiology, Ewha Womans University School of Medicine, Seoul (Korea, Republic of)

    2017-04-15

    Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  14. Doppler ultrasonography of the lower extremity arteries: anatomy and scanning guidelines

    Directory of Open Access Journals (Sweden)

    Ji Young Hwang

    2017-04-01

    Full Text Available Doppler ultrasonography of the lower extremity arteries is a valuable technique, although it is less frequently indicated for peripheral arterial disease than for deep vein thrombosis or varicose veins. Ultrasonography can diagnose stenosis through the direct visualization of plaques and through the analysis of the Doppler waveforms in stenotic and poststenotic arteries. To perform Doppler ultrasonography of the lower extremity arteries, the operator should be familiar with the arterial anatomy of the lower extremities, basic scanning techniques, and the parameters used in color and pulsed-wave Doppler ultrasonography.

  15. Effects of coil closure of patent ductus arteriosus on left anterior descending coronary artery blood flow using transthoracic Doppler echocardiography.

    Science.gov (United States)

    Harada, Kenji; Toyono, Manotomo; Tamura, Masamichi

    2004-06-01

    Transthoracic Doppler echocardiography provides noninvasive measurements of coronary blood flow in the left anterior descending coronary artery (LAD). This method has the potential to show the effects of acute changes in loading conditions on blood flow. Coil closure of patent ductus arteriosus (PDA) is a model of acute changes in blood pressure and left ventricular (LV) preload that influences coronary blood flow. We applied this technique to assess the coronary blood flow changes for patients with PDA before and immediately after PDA coil closure. We examined 9 patients (1.8 +/- 1.1 years) with simple PDA and 8 age-matched healthy children. LV dimensions and LV mass were measured. Maximum peak flow velocity and flow volume in the LAD were measured. Pulmonary to systemic flow ratios (Qp/Qs) were obtained by cardiac catheterization. After PDA coil closure, LV end-diastolic dimension decreased, and systolic and diastolic blood pressures increased significantly. The maximum peak flow velocity, LAD flow volume, and the ratio of LAD flow volume to LV mass increased significantly. The changes in maximum peak flow velocity and the ratio of LAD flow volume to LV mass (F/M) correlated positively with the changes in diastolic pressure and Qp/Qs. In 5 patients who had Qp/Qs > 1.5, the mean F/M was significantly lower compared with control subjects, but they increased to normal values after coil closure of PDA. PDA coil closure increases diastolic pressure and decreases Qp/Qs, resulting in improvement of myocardial perfusion. These findings provide new insights into the relationship between cardiac function and coronary circulation in pediatric patients with heart diseases associated with PDA.

  16. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy.

    Science.gov (United States)

    Khan, Sitara G; Klettas, Dimitris; Kapetanakis, Stam; Monaghan, Mark J

    2016-03-01

    Cardiac resynchronisation therapy (CRT) can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain) has conventionally been assessed using tissue Doppler imaging (TDI), which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference ('speckles') in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT. © 2016 The authors.

  17. Clinical utility of speckle-tracking echocardiography in cardiac resynchronisation therapy

    Directory of Open Access Journals (Sweden)

    Sitara G Khan

    2016-05-01

    Full Text Available Cardiac resynchronisation therapy (CRT can profoundly improve outcome in selected patients with heart failure; however, response is difficult to predict and can be absent in up to one in three patients. There has been a substantial amount of interest in the echocardiographic assessment of left ventricular dyssynchrony, with the ultimate aim of reliably identifying patients who will respond to CRT. The measurement of myocardial deformation (strain has conventionally been assessed using tissue Doppler imaging (TDI, which is limited by its angle dependence and ability to measure in a single plane. Two-dimensional speckle-tracking echocardiography is a technique that provides measurements of strain in three planes, by tracking patterns of ultrasound interference (‘speckles’ in the myocardial wall throughout the cardiac cycle. Since its initial use over 15 years ago, it has emerged as a tool that provides more robust, reproducible and sensitive markers of dyssynchrony than TDI. This article reviews the use of two-dimensional and three-dimensional speckle-tracking echocardiography in the assessment of dyssynchrony, including the identification of echocardiographic parameters that may hold predictive potential for the response to CRT. It also reviews the application of these techniques in guiding optimal LV lead placement pre-implant, with promising results in clinical improvement post-CRT.

  18. Stress echocardiography expert consensus statement

    NARCIS (Netherlands)

    R. Sicari (Rosa); P. Nihoyannopoulos (Petros); A. Evangelista (Arturo); J. Kasprzak (Jaroslav); P. Lancellotti (Patrizio); D. Poldermans (Don); J.U. Voigt; J.L. Zamorano (Jose)

    2008-01-01

    textabstractStress echocardiography is the combination of 2D echocardiography with a physical, pharmacological or electrical stress. The diagnostic end point for the detection of myocardial ischemia is the induction of a transient worsening in regional function during stress. Stress echocardiography

  19. 2010 Canadian Cardiovascular Society/Canadian Society of Echocardiography Guidelines for Training and Maintenance of Competency in Adult Echocardiography.

    Science.gov (United States)

    Burwash, Ian G; Basmadjian, Arsene; Bewick, David; Choy, Jonathan B; Cujec, Bibiana; Jassal, Davinder S; MacKenzie, Scott; Nair, Parvathy; Rudski, Lawrence G; Yu, Eric; Tam, James W

    2011-01-01

    Guidelines for the provision of echocardiography in Canada were jointly developed and published by the Canadian Cardiovascular Society and the Canadian Society of Echocardiography in 2005. Since their publication, recognition of the importance of echocardiography to patient care has increased, along with the use of focused, point-of-care echocardiography by physicians of diverse clinical backgrounds and variable training. New guidelines for physician training and maintenance of competence in adult echocardiography were required to ensure that physicians providing either focused, point-of-care echocardiography or comprehensive echocardiography are appropriately trained and proficient in their use of echocardiography. In addition, revision of the guidelines was required to address technological advances and the desire to standardize echocardiography training across the country to facilitate the national recognition of a physician's expertise in echocardiography. This paper summarizes the new Guidelines for Physician Training and Maintenance of Competency in Adult Echocardiography, which are considerably more comprehensive than earlier guidelines and address many important issues not previously covered. These guidelines provide a blueprint for physician training despite different clinical backgrounds and help standardize physician training and training programs across the country. Adherence to the guidelines will ensure that physicians providing echocardiography have acquired sufficient expertise required for their specific practice. The document will also provide a framework for other national societies to standardize their training programs in echocardiography and will provide a benchmark by which competency in adult echocardiography may be measured. Copyright © 2011 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  20. Explanation of the Inverse Doppler Effect Observed in Nonlinear Transmission Lines

    International Nuclear Information System (INIS)

    Kozyrev, Alexander B.; Weide, Daniel W. van der

    2005-01-01

    The theory of the inverse Doppler effect recently observed in magnetic nonlinear transmission lines is developed. We explain the crucial role of the backward spatial harmonic in the occurrence of an inverse Doppler effect and draw analogies of the magnetic nonlinear transmission line to the backward wave oscillator

  1. Echocardiography in chronic liver disease: systematic review.

    Science.gov (United States)

    Mota, Vitor Gomes; Markman Filho, Brivaldo

    2013-04-01

    Doppler echocardiography (Echo) is a non-invasive method of excellent accuracy to screen portopulmonary hypertension (PPH) and to assess intrapulmonary shunts (IPS) in chronic liver disease (CLD). In the past decade, Echo proved to play a fundamental role in the diagnosis of cirrhotic cardiomyopathy (CCM). To perform a systematic review of relevant articles on the subject 'Echo in CLD'. In November 2011, a systematic review was performed in the PubMed, LILACS and SciELO databases, and the characteristics of the studies selected were reported. The search based on descriptors and free terms obtained 204 articles (179 in Pubmed, 21 in LILACS, and 1 in SciELO). Of those 204 articles, 22 were selected for systematic review. A meta-analysis could not be performed because of the heterogeneity of the articles. Echo should be part of CLD stratification for screening PPH, IPS and CCM, because, most of the time, such complications are diagnosed only when patients are already waiting for a liver transplant.

  2. An ocean current inversion accuracy analysis based on a Doppler spectrum model

    Institute of Scientific and Technical Information of China (English)

    BAO Qingliu; ZHANG Youguang; LIN Mingsen; GONG Peng

    2017-01-01

    Microwave remote sensing is one of the most useful methods for observing the ocean parameters.The Doppler frequency or interferometric phase of the radar echoes can be used for an ocean surface current speed retrieval,which is widely used in spaceborne and airborne radars.While the effect of the ocean currents and waves is interactional.It is impossible to retrieve the ocean surface current speed from Doppler frequency shift directly.In order to study the relationship between the ocean surface current speed and the Doppler frequency shift,a numerical ocean surface Doppler spectrum model is established and validated with a reference.The input parameters of ocean Doppler spectrum include an ocean wave elevation model,a directional distribution function,and wind speed and direction.The suitable ocean wave elevation spectrum and the directional distribution function are selected by comparing the ocean Doppler spectrum in C band with an empirical geophysical model function (CDOP).What is more,the error sensitivities of ocean surface current speed to the wind speed and direction are analyzed.All these simulations are in Ku band.The simulation results show that the ocean surface current speed error is sensitive to the wind speed and direction errors.With VV polarization,the ocean surface current speed error is about 0.15 m/s when the wind speed error is 2 m/s,and the ocean surface current speed error is smaller than 0.3 m/s when the wind direction error is within 20° in the cross wind direction.

  3. Arterial wave reflection and subclinical left ventricular systolic dysfunction.

    Science.gov (United States)

    Russo, Cesare; Jin, Zhezhen; Takei, Yasuyoshi; Hasegawa, Takuya; Koshaka, Shun; Palmieri, Vittorio; Elkind, Mitchell Sv; Homma, Shunichi; Sacco, Ralph L; Di Tullio, Marco R

    2011-03-01

    Increased arterial wave reflection is a predictor of cardiovascular events and has been hypothesized to be a cofactor in the pathophysiology of heart failure. Whether increased wave reflection is inversely associated with left-ventricular (LV) systolic function in individuals without heart failure is not clear. Arterial wave reflection and LV systolic function were assessed in 301 participants from the Cardiovascular Abnormalities and Brain Lesions (CABL) study using two-dimensional echocardiography and applanation tonometry of the radial artery to derive central arterial waveform by a validated transfer function. Aortic augmentation index (AIx) and wasted energy index (WEi) were used as indices of wave reflection. LV systolic function was measured by LV ejection fraction (LVEF) and tissue Doppler imaging (TDI). Mitral annulus peak systolic velocity (Sm), peak longitudinal strain and strain rate were measured. Participants with history of coronary artery disease, atrial fibrillation, LVEF less than 50% or wall motion abnormalities were excluded. Mean age of the study population was 68.3 ± 10.2 years (64.1% women, 65% hypertensive). LV systolic function by TDI was lower with increasing wave reflection, whereas LVEF was not. In multivariate analysis, TDI parameters of LV longitudinal systolic function were significantly and inversely correlated to AIx and WEi (P values from 0.05 to 0.002). In a community cohort without heart failure and with normal LVEF, an increased arterial wave reflection was associated with subclinical reduction in LV systolic function assessed by novel TDI techniques. Further studies are needed to investigate the prognostic implications of this relationship.

  4. Galileo Probe Doppler Residuals as the Wave-Dynamical Signature of Weakly Stable, Downward-Increasing Stratification in Jupiter's Deep Wind Layer

    Science.gov (United States)

    Allison, Michael; Atkinson, David H.; Hansen, James E. (Technical Monitor)

    2001-01-01

    Doppler radio tracking of the Galileo probe-to-orbiter relay, previously analyzed for its in situ measure of Jupiter's zonal wind at the equatorial entry site, also shows a record of significant residual fluctuations apparently indicative of varying vertical motions. Regular oscillations over pressure depth in the residual Doppler measurements of roughly 1-8 Hz (increasing upward), as filtered over a 134 sec window, are most plausibly interpreted as gravity waves, and imply a weak, but downward increasing static stability within the 5 - 20 bar region of Jupiter's atmosphere. A matched extension to deeper levels of an independent inertial stability constraint from the measured vertical wind shear at 1 - 4 bars is roughly consistent with a static stability of approximately 0.5 K/km near the 20 bar level, as independently detected by the probe Atmospheric Structure Instrument.

  5. [Is standard-echocardiography sufficient for identification of responders?].

    Science.gov (United States)

    Neuss, M; Flach, P; Ali, T; Butter, C

    2006-01-01

    During recent years cardiac re-synchronization has become an important tool in the treatment of patients with signs and symptoms of heart failure and de-synchronized contraction of the heart. This article describes the pathophysiological basis of de-synchronized contraction due to left bundle branch block and the use of conventional echocardiography to unmask whether the electrical abnormality is accompanied by an asynchronous contraction in the individual patient. The altered contraction in the de-synchronized heart is analysed on different levels: atrioventricular dyssynchrony describes the disturbed mechanical coupling of the ventricles and atria, interventricular dyssynchrony describes the disturbed mechanical coupling of the left and right ventricle, and intraventricular dyssynchrony describes the uncoordinated contraction of the left ventricle. Since tissue Doppler imaging is implemented only in the top level echo machines of the respective manufacturers, this article uses parameters derived from standard echo techniques to analyse the different aspects of dyssynchrony.

  6. The practice of echocardiography

    International Nuclear Information System (INIS)

    Kraus, R.

    1985-01-01

    This volume is an anthology by noted authorities on all clinically useful aspects of echocardiography. Its articles cover such subjects as: historical perspectives, physics, instrumentation and techniques, M mode and 2D echocardiography

  7. Three-dimensional echocardiography of normal and pathologic mitral valve: a comparison with two-dimensional transesophageal echocardiography

    NARCIS (Netherlands)

    Salustri, A.; Becker, A. E.; van Herwerden, L.; Vletter, W. B.; ten Cate, F. J.; Roelandt, J. R.

    1996-01-01

    This study was done to ascertain whether three-dimensional echocardiography can facilitate the diagnosis of mitral valve abnormalities. The value of the additional information provided by three-dimensional echocardiography compared with two-dimensional multiplane transesophageal echocardiography for

  8. Prevalence of E/A wave fusion and A wave truncation in DDD pacemaker patients with complete AV block under nominal AV intervals.

    Directory of Open Access Journals (Sweden)

    Wolfram C Poller

    Full Text Available Optimization of the AV-interval (AVI in DDD pacemakers improves cardiac hemodynamics and reduces pacemaker syndromes. Manual optimization is typically not performed in clinical routine. In the present study we analyze the prevalence of E/A wave fusion and A wave truncation under resting conditions in 160 patients with complete AV block (AVB under the pre-programmed AVI. We manually optimized sub-optimal AVI.We analyzed 160 pacemaker patients with complete AVB, both in sinus rhythm (AV-sense; n = 129 and under atrial pacing (AV-pace; n = 31. Using Doppler analyses of the transmitral inflow we classified the nominal AVI as: a normal, b too long (E/A wave fusion or c too short (A wave truncation. In patients with a sub-optimal AVI, we performed manual optimization according to the recommendations of the American Society of Echocardiography.All AVB patients with atrial pacing exhibited a normal transmitral inflow under the nominal AV-pace intervals (100%. In contrast, 25 AVB patients in sinus rhythm showed E/A wave fusion under the pre-programmed AV-sense intervals (19.4%; 95% confidence interval (CI: 12.6-26.2%. A wave truncations were not observed in any patient. All patients with a complete E/A wave fusion achieved a normal transmitral inflow after AV-sense interval reduction (mean optimized AVI: 79.4 ± 13.6 ms.Given the rate of 19.4% (CI 12.6-26.2% of patients with a too long nominal AV-sense interval, automatic algorithms may prove useful in improving cardiac hemodynamics, especially in the subgroup of atrially triggered pacemaker patients with AV node diseases.

  9. ECHOCARDIOGRAPHIC FINDINGS OF BIDIMENSIONAL MODE, M-MODE, AND DOPPLER OF CLINICALLY NORMAL BLACK-RUMPED AGOUTI (DASYPROCTA PRYMNOLOPHA, WAGLER 1831).

    Science.gov (United States)

    Diniz, Anaemilia das Neves; Pessoa, Gerson Tavares; da Silva Moura, Laecio; de Sousa, André Braga; Sousa, Francisco das Chagas Araújo; de Sá Rodrigues, Renan Paraguassu; da Silva Barbosa, Maria Angélica Parente; de Almeida, Hatawa Melo; Freire, Larisse Danielle Silva; Sanches, Marina Pinto; Júnior, Antônio Augusto Nascimento Machado; Guerra, Porfírio Candanedo; Neves, Willams Costa; de Sousa, João Macedo; Bolfer, Luiz; Giglio, Robson Fortes; Alves, Flávio Ribeiro

    2017-06-01

    The black-rumped agouti ( Dasyprocta prymnolopha , Wagler 1831) is currently under intense ecologic pressure, which has resulted in its disappearance from some regions of Brazil. Echocardiography is widely used in veterinary medicine but it is not yet part of the clinical routine for wild animals. The objective of the present study was to assess the applicability of the echocardiographic exam in nonanesthetized agouti and to establish normal reference values for echocardiographic measurements in bidimensional mode (2D), M-mode, and Doppler for this species, and a lead II electrocardiogram was simultaneously recorded. Twenty agouti were used in this study. All the echocardiographic measurements were positively correlated with weight (P 0.05). Blood flow velocities in the pulmonary and aortic artery ranged from 67.32-71.28 cm/sec and 79.22-101.84 cm/sec, respectively. The isovolumic relaxation time was assessed in all the animals and ranged from 38.5 to 56.6 ms. The maximum value for the nonfused E and A waves and the Et and At waves was 158 beats/min for both. The results obtained for the morphologic and heart hemodynamic measurements can guide future studies and help in the clinical management of these animals in captivity.

  10. American Society of Echocardiography

    Science.gov (United States)

    American Society of Echocardiography Join Ase Renew Member Portal Log In Membership Member Portal Log In Join ASE Renew Benefits Rates FASE – Fellow of the American Society of Echocardiography Member Referral Program FAQs Initiatives Advocacy Awards, Grants, ...

  11. The feasibility of measuring renal blood flow using transesophageal echocardiography in patients undergoing cardiac surgery.

    Science.gov (United States)

    Yang, Ping-Liang; Wong, David T; Dai, Shuang-Bo; Song, Hai-Bo; Ye, Ling; Liu, Jin; Liu, Bin

    2009-05-01

    There is no reliable method to monitor renal blood flow intraoperatively. In this study, we evaluated the feasibility and reproducibility of left renal blood flow measurements using transesophageal echocardiography during cardiac surgery. In this prospective noninterventional study, left renal blood flow was measured with transesophageal echocardiography during three time points (pre-, intra-, and postcardiopulmonary bypass) in 60 patients undergoing cardiac surgery. Sonograms from 6 subjects were interpreted by 2 blinded independent assessors at the time of acquisition and 6 mo later. Interobserver and intraobserver reproducibility were quantified by calculating variability and intraclass correlation coefficients. Patients with Doppler angles of >30 degrees (20 of 60 subjects) were eliminated from renal blood flow measurements. Left renal blood flow was successfully measured and analyzed in 36 of 60 (60%) subjects. Both interobserver and intraobserver variability were renal blood flow measurements were good to excellent (intraclass correlation coefficients 0.604-0.999). Left renal arterial luminal diameter for the pre, intra, and postcardiopulmonary bypass phases, ranged from 3.8 to 4.1 mm, renal arterial velocity from 25 to 35 cm/s, and left renal blood flow from 192 to 299 mL/min. In patients undergoing cardiac surgery, it was feasible in 60% of the subjects to measure left renal blood flow using intraoperative transesophageal echocardiography. The interobserver and intraobserver reproducibility of renal blood flow measurements was good to excellent.

  12. Numerical stud of glare spot phase Doppler anemometry

    OpenAIRE

    Hespel , Camille; Ren , Kuan Fang; Gréhan , Gérard; Onofri , Fabrice

    2008-01-01

    International audience; The phase Doppler anemometry has (PDA) been developed to measure simultaneously the velocity and the size of droplets. When the concentration of particles is high, tightly focused beams must be used, as in the dual burst PDA. The latter permits an access to the refractive index of the particle, but the effect of wave front curvature of the incident beams becomes evident. In this paper, we introduce a glare spot phase Doppler anemometry which uses two large beams. The i...

  13. Role of modern 3D echocardiography in valvular heart disease

    Science.gov (United States)

    2014-01-01

    Three-dimensional (3D) echocardiography has been conceived as one of the most promising methods for the diagnosis of valvular heart disease, and recently has become an integral clinical tool thanks to the development of high quality real-time transesophageal echocardiography (TEE). In particular, for mitral valve diseases, this new approach has proven to be the most unique, powerful, and convincing method for understanding the complicated anatomy of the mitral valve and its dynamism. The method has been useful for surgical management, including robotic mitral valve repair. Moreover, this method has become indispensable for nonsurgical mitral procedures such as edge to edge mitral repair and transcatheter closure of paravaluvular leaks. In addition, color Doppler 3D echo has been valuable to identify the location of the regurgitant orifice and the severity of the mitral regurgitation. For aortic and tricuspid valve diseases, this method may not be quite as valuable as for the mitral valve. However, the necessity of 3D echo is recognized for certain situations even for these valves, such as for evaluating the aortic annulus for transcatheter aortic valve implantation. It is now clear that this method, especially with the continued development of real-time 3D TEE technology, will enhance the diagnosis and management of patients with these valvular heart diseases. PMID:25378966

  14. The transesophageal echocardiography simulator based on computed tomography images.

    Science.gov (United States)

    Piórkowski, Adam; Kempny, Aleksander

    2013-02-01

    Simulators are a new tool in education in many fields, including medicine, where they greatly improve familiarity with medical procedures, reduce costs, and, importantly, cause no harm to patients. This is so in the case of transesophageal echocardiography (TEE), in which the use of a simulator facilitates spatial orientation and helps in case studies. The aim of the project described in this paper is to simulate an examination by TEE. This research makes use of available computed tomography data to simulate the corresponding echocardiographic view. This paper describes the essential characteristics that distinguish these two modalities and the key principles of the wave phenomena that should be considered in the simulation process, taking into account the conditions specific to the echocardiography. The construction of the CT2TEE (Web-based TEE simulator) is also presented. The considerations include ray-tracing and ray-casting techniques in the context of ultrasound beam and artifact simulation. An important aspect of the interaction with the user is raised.

  15. Echocardiography-guided or "sided" pericardiocentesis.

    Science.gov (United States)

    Degirmencioglu, Aleks; Karakus, Gultekin; Güvenc, Tolga Sinan; Pinhan, Osman; Sipahi, Ilke; Akyol, Ahmet

    2013-10-01

    Echocardiography-guided pericardiocentesis is the first choice method for relieving cardiac tamponade, but the exact role of the echocardiography at the moment of the puncture is still controversial. In this report, detailed echocardiographic evaluation was performed in 21 consecutive patients with cardiac tamponade just before the pericardiocentesis. Appropriate needle position was determined according to the probe position using imaginary x, y, and z axes. Pericardiocentesis was performed successfully using this technique without simultaneous echocardiography and no complications were observed. We concluded that bedside echocardiography with detailed evaluation of the puncture site and angle is enough for pericardiocentesis instead of real time guiding. © 2013, Wiley Periodicals, Inc.

  16. Determination of testicular blood flow in camelids using vascular casting and color pulsed-wave Doppler ultrasonography.

    Science.gov (United States)

    Kutzler, Michelle; Tyson, Reid; Grimes, Monica; Timm, Karen

    2011-01-01

    We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV) was higher in fertile males compared to infertile males (P = 0.0004). In addition, end diastolic velocity (EDV) within the supratesticular arteries was higher for fertile males when compared to infertile males (P = 0.0325). Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P = 0.0104). However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P = 0.121). In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P = 0.486) and marginal arteries (P = 0.144). The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  17. Determination of Testicular Blood Flow in Camelids Using Vascular Casting and Color Pulsed-Wave Doppler Ultrasonography

    Directory of Open Access Journals (Sweden)

    Michelle Kutzler

    2011-01-01

    Full Text Available We describe the vasculature of the camelid testis using plastic casting. We also use color pulsed-wave Doppler ultrasonography to measure testicular blood flow and compare the differences between testicular blood flow in fertile and infertile camelids. The testicular artery originates from the ventral surface of the aorta, gives rise to an epididymal branch, and becomes very tortuous as it approaches the testis. Within the supratesticular arteries, peak systolic velocity (PSV was higher in fertile males compared to infertile males (P=0.0004. In addition, end diastolic velocity (EDV within the supratesticular arteries was higher for fertile males when compared to infertile males (P=0.0325. Within the marginal arteries, PSV was also higher in fertile males compared to infertile males (P=0.0104. However, EDV within the marginal arteries was not significantly different between fertile and infertile males (P=0.121. In addition, the resistance index was not significantly different between fertile and infertile males within the supratesticular (P=0.486 and marginal arteries (P=0.144. The significance of this research is that in addition to information obtained from a complete reproductive evaluation, a male camelid's fertility can be determined using testicular blood flow measured by Doppler ultrasonography.

  18. Bedside Echocardiography for Rapid Diagnosis of Malignant Cardiac Tamponade

    Directory of Open Access Journals (Sweden)

    Alaina Brinley

    2017-01-01

    Full Text Available History of present illness: A 47-year-old female with metastatic breast cancer presented to the Emergency Department with chest pain and shortness of breath. She was hypotensive and her EKG showed sinus tachycardia with low voltage. A bedside ultrasound was performed that detected a pericardial effusion and evidence of cardiac tamponade. The patient’s vitals improved with a fluid bolus and she went emergently to the cardiac catheterization lab for fluoroscopy and echocardiography guided pericardiocentesis. A total of 770 mL of fluid was removed from her pericardial space. Significant findings: The video shows a subxiphoid view of the heart with evidence of a large pericardial effusion with tamponade – note the anechoic stripe in the pericardial sac (see red arrow. This video demonstrates paradoxical right ventricular collapse during diastole and right atrial collapse during systole which is indicative of tamponade.1,2 Figure 1 is from the same patient and shows sonographic pulsus paradoxus. This is an apical 4 chamber view of the heart with the sampling gate of the pulsed wave doppler placed over the mitral valve. The Vpeak max and Vpeak min are indicated. If there is more than a 25% difference with inspiration between these 2 values, this is highly suggestive of tamponade.1 In this case, there is a 32.4% difference between the Vpeak max 69.55 cm/s and Vpeak min 46.99 cm/s. Discussion: Cardiac tamponade is distinguished from pericardial effusion by right ventricular compression/collapse and hemodynamic instability. Findings can include hypotension, tachycardia, distant heart sounds, and jugular venous distension.3,4 One might also see a plethoric IVC without respiratory variation indicative of elevated right atrial pressures.1 Detection of right ventricular collapse for cardiac tamponade has sensitivities ranging from 48%-100% and specificities ranging from 33%-100%.5 A larger effusion is more likely to lead to cardiac tamponade. However

  19. Doppler-echocardiographic assessment of valvular regurgitation in healthy young subjects

    International Nuclear Information System (INIS)

    Filcheva, K.; Gochev, D.; Petrovski, P.; Kotsev, P.

    1995-01-01

    The study covers 300 clinically healthy, randomly selected young subjects, aged 17 to 21 years. The incidence and characteristic features of the valvular regurgitations are assayed by means of pulsed and continuous transthoracic Doppler echocardiography. Valvular insufficiency is registered in total of 198 cases (66%). Regurgitation of single valve is observed in 122 cases (61%), regurgitation of two valves - in 70 (36%) and three valves - in six (3%). Right-sided regurgitations (tricuspid, pulmonic and a combination of both) are detected in 156 subjects, and left-sided (mitral and/or aortic) in twenty-six of which only one regurgitation of the aortic valve. There is a definite tendency of the first two to prevail at a ratio 6:1. A constellation of various anatomical and physiological factors are considered as a likely underlying cause. Whenever atrio-ventricular valves are examined (the mitral one in particular), it is necessary that the regurgitation jet involves over 50% of systole in order to avoid hyperdiagnostics and the so-called 'Doppler's disease'. 14 refs., 1 tab., 2 figs. (author)

  20. Pulsed-wave tissue Doppler imaging of the myocardium of cats with induced thyrotoxicosis Doppler tecidual pulsado do miocárdio de gatos com tirotoxicose induzida

    Directory of Open Access Journals (Sweden)

    Daniel Capucho de Oliveira

    2011-06-01

    Full Text Available Left ventricular myocardial motion was quantified using pulsed-wave tissue Doppler imaging (PW-TDI in nine adult cats before and after thyrotoxicosis induction. In order to induce thyrotoxicosis, all cats were given 150µg kg-1 of levothyroxine sodium as a single oral dose each day for 10 weeks. PW-TDI examinations were performed immediately before the induction and by the end of the experimental protocol. An increase in myocardial motion velocity was documented at the interventricular septum level, demonstrated by an elevation in systolic (Sa, and early (Ea and late (Aa diastolic waves (PA velocidade de movimentação miocárdica do ventrículo esquerdo foi quantificada por meio de exames ecocardiográficos com Doppler tecidual pulsado (PW-TDI em nove gatos adultos antes e após indução à tirotoxicose. Para indução da tirotoxicose, todos os gatos receberam doses diárias de 150mg kg-1 de levotiroxina sódica, por via oral, durante 10 semanas. Os exames de PW-TDI foram realizados imediatamente antes da indução e ao final do protocolo experimental. Uma elevação na velocidade de movimentação miocárdica foi documentada ao nível do septo interventricular, demonstrado por um aumento das ondas sistólica (Sa e diastólicas (Ea e Aa; P<0,05. No entanto, nenhuma alteração nos valores de Sa, Ea e Aa foi encontrada ao nível da parede livre do ventrículo esquerdo. A frequência cardíaca aumentou significativamente entre os momentos experimentais, sendo que três animais apresentaram fusão das ondas Aa e Ea ao final do experimento. O protocolo experimental utilizado neste estudo causou alterações na velocidade de movimentação do miocárdio ventricular esquerdo, mas sem causar danos à função diastólica do ventrículo esquerdo.

  1. Left Ventricular Stroke Volume Quantification by Contrast Echocardiography – Comparison of Linear and Flow-Based Methods to Cardiac Magnetic Resonance

    Science.gov (United States)

    Dele-Michael, Abiola O.; Fujikura, Kana; Devereux, Richard B; Islam, Fahmida; Hriljac, Ingrid; Wilson, Sean R.; Lin, Fay; Weinsaft, Jonathan W.

    2014-01-01

    Background Echocardiography (echo) quantified LV stroke volume (SV) is widely used to assess systolic performance after acute myocardial infarction (AMI). This study compared two common echo approaches – predicated on flow (Doppler) and linear chamber dimensions (Teichholz) – to volumetric SV and global infarct parameters quantified by cardiac magnetic resonance (CMR). Methods Multimodality imaging was performed as part of a post-AMI registry. For echo, SV was measured by Doppler and Teichholz methods. Cine-CMR was used for volumetric SV and LVEF quantification, and delayed-enhancement CMR for infarct size. Results 142 patients underwent same-day echo and CMR. On echo, mean SV by Teichholz (78±17ml) was slightly higher than Doppler (75±16ml; Δ=3±13ml, p=0.02). Compared to SV on CMR (78±18ml), mean difference by Teichholz (Δ=−0.2±14; p=0.89) was slightly smaller than Doppler (Δ−3±14; p=0.02) but limits of agreement were similar between CMR and echo methods (Teichholz: −28, 27 ml, Doppler: −31, 24ml). For Teichholz, differences with CMR SV were greatest among patients with anteroseptal or lateral wall hypokinesis (p<0.05). For Doppler, differences were associated with aortic valve abnormalities or root dilation (p=0.01). SV by both echo methods decreased stepwise in relation to global LV injury as assessed by CMR-quantified LVEF and infarct size (p<0.01). Conclusions Teichholz and Doppler calculated SV yield similar magnitude of agreement with CMR. Teichholz differences with CMR increase with septal or lateral wall contractile dysfunction, whereas Doppler yields increased offsets in patients with aortic remodeling. PMID:23488864

  2. Clinical applications of contrast echocardiography

    International Nuclear Information System (INIS)

    Jorge, Leon Galindo

    2005-01-01

    The echocardiography is the technique more used for the diagnosis and pursuit of the cardiovascular illnesses; therefore, their diagnostic precision has acquired a vital importance in the handling of the patients with cardiovascular pathologies. However, with relative frequency, the diagnostic capacity of the echocardiography exam is diminished by limitations of the acoustic window, mainly in-patient with obesity, lung illnesses and alterations of the thoracic wall. This can be obviated with the use of the intra-esophagus echocardiography, although this it is a procedure semi-invasive and not very practical of carrying out in all the patients with problems of acoustic window. In this article the clinical applications are revised more common of the contrast echocardiography

  3. Fetal echocardiography

    International Nuclear Information System (INIS)

    Chaubal, Nitin G.; Chaubal, Jyoti

    2009-01-01

    USG performed with a high-end machine, using a good cine-loop facility is extremely helpful in the diagnosis of fetal cardiac anomalies. In fetal echocardiography, the four-chamber view and the outflow-tract view are used to diagnose cardiac anomalies. The most important objective during a targeted anomaly scan is to identify those cases that need a dedicated fetal echocardiogram. Associated truncal and chromosomal anomalies need to be identified. This review shows how fetal echocardiography, apart from identifying structural defects in the fetal heart, can be used to look at rhythm abnormalities and other functional aspects of the fetal heart

  4. Pulmonary artery occlusion pressure estimation by transesophageal echocardiography: is simpler better?

    Science.gov (United States)

    Voga, Gorazd

    2008-01-01

    The measurement of pulmonary artery occlusion pressure (PAOP) is important for estimation of left ventricular filling pressure and for distinction between cardiac and non-cardiac etiology of pulmonary edema. Clinical assessment of PAOP, which relies on physical signs of pulmonary congestion, is uncertain. Reliable PAOP measurement can be performed by pulmonary artery catheter, but it is possible also by the use of echocardiography. Several Doppler variables show acceptable correlation with PAOP and can be used for its estimation in cardiac and critically ill patients. Noninvasive PAOP estimation should probably become an integral part of transthoracic and transesophageal echocardiographic evaluation in critically ill patients. However, the limitations of both methods should be taken into consideration, and in specific patients invasive PAOP measurement is still unavoidable, if the exact value of PAOP is needed.

  5. Fetal cardiology

    International Nuclear Information System (INIS)

    Meijboom, E.J.; Rijsterborgh, N.; Bom, N.

    1986-01-01

    Doppler echocardiography makes it possible to diagnose congenital heart disease in early pregnancy. It allows us to study the anatomical configuration of the fetal heart, and additionally, to evaluate the physiological conditions of the fetus. Evaluation of the direction, velocity, wave form pattern, and quantification of blood flow at the various sites in the fetal heart helps us to assess the characteristics of the fetal circulation and condition of the fetal heart. In order to use this technique in pathological situations, an initial study of the developing normal human fetal circulation was necessary. The authors studied 34 uncomplicated pregnancies by serial Doppler echocardiography. The studies were performed every 4 weeks from 16-weeks gestation to term. The pulsed Doppler sector scanner provided cardiac cross-sectional images, mitral and tricuspid blood velocities were obtained from apical four-chamber views. Angle corrected maximal and mean temporal velocities were calculated by digitizing the Doppler frequency shift recording on a graphic tablet computed with a minicomputer. The angle between the Doppler interrogation beam and the direction of blood flow was kept as small as possible in order to minimize the error

  6. New pulmonary vein Doppler echocardiographic index predicts significant interatrial shunting in secundum atrial septal defect.

    Science.gov (United States)

    Lam, Yat-Yin; Fang, Fang; Yip, Gabriel Wai-Kwok; Li, Zhi-An; Yang, Ya; Yu, Cheuk-Man

    2012-09-20

    The relation between pulmonary venous flow (PVF) pattern and degree of left-to-right interatrial shunting (IAS) in patients with secundum atrial septal defect (ASD) is unknown. Fifty consecutive ASD patients (14 males, 36 ± 17 years) received transthoracic echocardiography (TTE) before and 1 day after transcatheter closure and their results were compared to 40 controls. The ratio of pulmonary-to-systemic flows (Qp/Qs) was assessed by TTE and invasive oximetry. Pre-closure PV systolic (PVs), diastolic (PVd) velocities and velocity-time integral (PV-VTI) increased, time from onset of ECG Q-wave to the peak PV diastolic wave (Q-PVd) shortened and atrial reversal (PVar) velocity significantly decreased as compared to normals. These findings normalized after closure. Patients with large IAS (defined as invasive Qp/Qs ≥ 2) had higher PVs, PVd and PV-VTI, shorter Q-PVd but lower PVar (all pIAS. Invasive Qp/Qs ratios correlated with PVs, PVd, PV-VTI, Q-PVd and TTE-derived Qp/Qs ratios, ASD sizes and RV end-diastolic dimensions (all pIAS after multivariate analysis. The corresponding sensitivity, specificity and AUC were 89%, 82% and 0.90 respectively for a PV-VTI of 30 cm (pIAS have distinguishable PVF features. Doppler evaluation of PV-VTI is a novel additional tool for assessing the magnitude of shunting in these patients non-invasively. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  7. Three-Dimensional Echocardiography-Derived Non-Invasive Right Ventricular Pressure-Volume Analysis.

    Science.gov (United States)

    Huang, Kuan-Chih; Lin, Lian-Yu; Hwang, Juey-Jen; Lin, Lung-Chun

    2017-09-01

    In patients with pulmonary hypertension, repeated evaluations of right ventricular (RV) function are still required for clinical decision making, but the invasive nature of current pressure-volume analysis makes conducting regular follow-ups in a clinical setting infeasible. We enrolled 12 patients with pulmonary arterial hypertension (PAH) and 10 with pulmonary venous hypertension (PVH) May 2016-October 2016. All patients underwent a clinically indicated right heart catheterization (RHC), from which the yielded right ventricular pressure recordings were conjugated with RV volume by 3-D echocardiography to generate a pressure-volume loop. A continuous-wave Doppler envelope of tricuspid regurgitation was transformed into a pressure gradient recording by the simplified Bernoulli equation, and then a systolic pressure gradient-volume (PG-V) diagram was generated from similar methods. The area enclosed by the pressure-volume loop was calculated to represent semi-invasive right ventricular stroke work (RVSW RHC ). The area between the PG-V diagram and x-axis was calculated to estimate non-invasive RVSW (RVSW echo ). Patients with PAH have higher RV pressure, lower pulmonary arterial wedge pressure and larger RV volume that was contributed by the dilation of RV mid-cavity minor dimension. We found no significant difference of traditional parameters between these two groups, but RVSW values were significantly higher in PAH patients. The RVSW values of these two methods were significantly correlated by the equation RVSW echo  = 0.8447 RVSW RHC  + 129.38 (R 2  = 0.9151, p rights reserved.

  8. The Role of Color Doppler Ultrasonography in Characterization of Thyroid Tumors

    International Nuclear Information System (INIS)

    Kim, Hee Soo; Jeon, Pyong; Won, Jong Yoon; Na, Jae Beom; Lee, Hyang Mee; Yoo, Hyung Sik; Lee, Jong Tae; Park, Jeong Soo; Cho, Nam Hoon

    1995-01-01

    To assess the usefulness of color Doppler ultrasonography in the characterization of thyroid tumors, surgically proven 88 nodules in 85 patients were evaluated. Using 10 MHz linear array transducer, gray scale images were initially evaluated. Then, distribution pattern of color signals (marginal, intra-tumoral, mixed) and graded internal vascularity according to morphology of color signal (0:absence of internal signal, 1: spotty, 2: linear,3: branching) were observed on color doppler imaging. Pulsed doppler waves were analyzed with parameters including peak systolic velocity(PSV), resistive index(RI), and pulsatile index(PI). Significantly larger numbers of intra-tumoral type, 20 cases(62.5%), were observed in malignant nodules, whereas mixed forms were predominant in benign group, 37 cases (66%) In graded internal vascularity, malignant nodules tended to have grade 2 or 3 signals, whereas benign nodules tended to have grade 0 or 1 signals. Spectral wave analysis show no significant difference in the value of PSV, RI, and PI between malignancy and benignity group. In conclusion, color Doppler imaging has a potential role in the characterization of thyroid nodules as a supportive method for gray scale diagnosis

  9. Coherent Detection in Laser Doppler Velocimeters

    DEFF Research Database (Denmark)

    Hanson, Steen Grüner

    1974-01-01

    , but intelligible particle picture of electromagnetic waves. The analysis is carried out with special emphasis on the heterodyning process in the laser Doppler velocimeter (LDV) because the main purpose of this article is to provide a better understanding of this instrument. An aid for this purpose......The possibility of heterodyning between electromagnetic waves scattered by particles separated in space is explained from a classical point of view and from a quantum mechanical point of view. The last description being carried out using only the Heisenberg uncertainty principle and a rather coarse...

  10. Echocardiography in the Era of Multimodality Cardiovascular Imaging

    Science.gov (United States)

    Shah, Benoy Nalin

    2013-01-01

    Echocardiography remains the most frequently performed cardiac imaging investigation and is an invaluable tool for detailed and accurate evaluation of cardiac structure and function. Echocardiography, nuclear cardiology, cardiac magnetic resonance imaging, and cardiovascular-computed tomography comprise the subspeciality of cardiovascular imaging, and these techniques are often used together for a multimodality, comprehensive assessment of a number of cardiac diseases. This paper provides the general cardiologist and physician with an overview of state-of-the-art modern echocardiography, summarising established indications as well as highlighting advances in stress echocardiography, three-dimensional echocardiography, deformation imaging, and contrast echocardiography. Strengths and limitations of echocardiography are discussed as well as the growing role of real-time three-dimensional echocardiography in the guidance of structural heart interventions in the cardiac catheter laboratory. PMID:23878804

  11. Guideline from Japanese Society of Echocardiography: 2018 focused update incorporated into Guidance for the Management and Maintenance of Echocardiography Equipment.

    Science.gov (United States)

    Daimon, Masao; Akaishi, Makoto; Asanuma, Toshihiko; Hashimoto, Shuji; Izumi, Chisato; Iwanaga, Shiro; Kawai, Hiroya; Toide, Hiroyuki; Hayashida, Akihiro; Yamada, Hirotsugu; Murata, Mitsushige; Hirano, Yutaka; Suzuki, Kengo; Nakatani, Satoshi

    2018-03-01

    Echocardiography plays a pivotal role as an imaging modality in the modern cardiology practice. Information derived from echocardiography is definitely helpful for a patient care. The Japanese Society of Echocardiography has promoted echocardiography for a routine clinical and research use. One of the missions of the Society is to provide information that is useful for high-quality examinations. To ensure it, we believe equipment in good conditions and a comfortable environment are important for both a patient and an examiner. Thus, the Committee for Guideline Writing, the Japanese Society of Echocardiography published brief guidance for the routine use of echocardiography equipment in 2015. Recently, the importance of international standardization has been emphasized in the medical laboratories. Accordingly, the committee has revised and updated our guidance for the routine use of echocardiography equipment.

  12. Tissue Doppler echocardiography improves the diagnosis of coronary artery stenosis in stable angina pectoris

    DEFF Research Database (Denmark)

    Hoffmann, Soren; Jensen, Jan Skov; Iversen, Allan Zeeberg

    2012-01-01

    Aim To determine if colour tissue Doppler imaging (TDI) performed at rest in patients with suspected stable angina pectoris (SAP) is able to predict the presence of significant coronary artery disease (CAD). METHODS AND RESULTS: This study comprises 296 consecutive patients with clinically...... by colour TDI at six mitral annular sites and averaged to provide global estimates. Duke score (DS), including ST depression, chest pain, and exercise capacity, was used as the outcome of the exercise ECG. Patients with an area stenosis of ≥70% in at least one epicardial coronary artery were categorized...

  13. Prevalence of Rheumatic Heart Disease in a Public School of Belo Horizonte

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, Lavinia Pimentel, E-mail: lavinia.pimentel@globo.com; Camargos, Paulo Augusto Moreira; Torres, Rosália Morais; Meira, Zilda Maria Alves [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)

    2014-08-15

    Previous studies indicate that compared with physical examination, Doppler echocardiography identifies a larger number of cases of rheumatic heart disease in apparently healthy individuals. To determine the prevalence of rheumatic heart disease among students in a public school of Belo Horizonte by clinical evaluation and Doppler echocardiography. This was a cross-sectional study conducted with 267 randomly selected school students aged between 6 and 16 years. students underwent anamnesis and physical examination with the purpose of establishing criteria for the diagnosis of rheumatic fever. They were all subjected to Doppler echocardiography using a portable machine. Those who exhibited nonphysiological mitral regurgitation (MR) and/or aortic regurgitation (AR) were referred to the Doppler echocardiography laboratory of the Hospital das Clínicas of the Universidade Federal of Minas Gerais (HC-UFMG) to undergo a second Doppler echocardiography examination. According to the findings, the cases of rheumatic heart disease were classified as definitive, probable, or possible. Of the 267 students, 1 (0.37%) had a clinical history compatible with the diagnosis of acute rheumatic fever (ARF) and portable Doppler echocardiography indicated nonphysiological MR and/or AR in 25 (9.4%). Of these, 16 (6%) underwent Doppler echocardiography at HC-UFMG. The results showed definitive rheumatic heart disease in 1 student, probable rheumatic heart disease in 3 students, and possible rheumatic heart disease in 1 student. In the population under study, the prevalence of cases compatible with rheumatic involvement was 5 times higher on Doppler echocardiography (18.7/1000; 95% CI 6.9/1000-41.0/1000) than on clinical evaluation (3.7/1000-95% CI)

  14. Prevalence of Rheumatic Heart Disease in a Public School of Belo Horizonte

    International Nuclear Information System (INIS)

    Miranda, Lavinia Pimentel; Camargos, Paulo Augusto Moreira; Torres, Rosália Morais; Meira, Zilda Maria Alves

    2014-01-01

    Previous studies indicate that compared with physical examination, Doppler echocardiography identifies a larger number of cases of rheumatic heart disease in apparently healthy individuals. To determine the prevalence of rheumatic heart disease among students in a public school of Belo Horizonte by clinical evaluation and Doppler echocardiography. This was a cross-sectional study conducted with 267 randomly selected school students aged between 6 and 16 years. students underwent anamnesis and physical examination with the purpose of establishing criteria for the diagnosis of rheumatic fever. They were all subjected to Doppler echocardiography using a portable machine. Those who exhibited nonphysiological mitral regurgitation (MR) and/or aortic regurgitation (AR) were referred to the Doppler echocardiography laboratory of the Hospital das Clínicas of the Universidade Federal of Minas Gerais (HC-UFMG) to undergo a second Doppler echocardiography examination. According to the findings, the cases of rheumatic heart disease were classified as definitive, probable, or possible. Of the 267 students, 1 (0.37%) had a clinical history compatible with the diagnosis of acute rheumatic fever (ARF) and portable Doppler echocardiography indicated nonphysiological MR and/or AR in 25 (9.4%). Of these, 16 (6%) underwent Doppler echocardiography at HC-UFMG. The results showed definitive rheumatic heart disease in 1 student, probable rheumatic heart disease in 3 students, and possible rheumatic heart disease in 1 student. In the population under study, the prevalence of cases compatible with rheumatic involvement was 5 times higher on Doppler echocardiography (18.7/1000; 95% CI 6.9/1000-41.0/1000) than on clinical evaluation (3.7/1000-95% CI)

  15. Estimation of diastolic filling pressure with cardiac CT in comparison with echocardiography using tissue doppler imaging: Determination of optimal CT reconstruction parameters

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Sun; Suh, Jon; Lee, Heon [Soonchunhyang University Hospital Bucheon, Bucheon (Korea, Republic of); Lee, Bora [Dept. of Biostatistics, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of); Lee, Soo Jeong [Terarecon Korea, Seoul (Korea, Republic of); Jou, Sung Shick [Dept. of Radiology, Soonchunhyang University Hospital Cheonan, Cheonan (Korea, Republic of); Lim, Hyun Kyung [Dept. of Radiology, Soonchunhyang University Hospital Seoul, Seoul (Korea, Republic of)

    2017-08-01

    To determine the optimal CT image reconstruction parameters for the measurement of early transmitral peak velocity (E), early peak mitral septal tissue velocity (E′), and E / E′. Forty-six patients underwent simultaneous cardiac CT and echocardiography on the same day. Four CT datasets were reconstructed with a slice thickness/interval of 0.9/0.9 mm or 3/3 mm at 10 (10% RR-interval) or 20 (5% RR-interval) RR-intervals. The E was calculated by dividing the peak transmitral flow (mL/s) by the corresponding mitral valve area (cm{sup 2}). E′ was calculated from the changes in the left ventricular length per cardiac phase. E / E′ was then estimated and compared with that from echocardiography. For assessment of E / E′, CT and echocardiography were more strongly correlated (p < 0.05) with a slice thickness of 0.9 mm and 5% RR-interval (r = 0.77) than with 3 mm or 10% RR-interval. The diagnostic accuracy of predicting elevated filling pressure (E / E′ ≥ 13, n = 14) was better with a slice thickness of 0.9 mm and 5% RR-interval (87.0%) than with 0.9 mm and 10% RR-interval (71.7%) (p = 0.123) and significantly higher than that with a slice thickness of 3 mm with 5% (67.4%) and 10% RR-interval (63.0%), (p < 0.05), respectively. Data reconstruction with a slice thickness of 0.9 mm at 5% RR-interval is superior to that with a slice thickness of 3 mm or 10% RR-interval in terms of the correlation of E / E′ between CT and echocardiography. Thin slices and frequent sampling also allow for more accurate prediction of elevated filling pressure.

  16. Transesophageal echocardiography in NeoChord procedure

    Directory of Open Access Journals (Sweden)

    Pittarello Demetrio

    2015-01-01

    Full Text Available Background: Transapical off-pump mitral valve intervention with neochord implantation for degenerative mitral valve disease have been recently introduced in the surgical practice. The procedure is performed under 2D-3D transesophageal echocardiography guidance. Methods: The use of 3D real-time transesophageal echocardiography provides more accurate information than 2D echocardiography only in all the steps of the procedure. In particular 3D echocardiography is mandatory for preoperative assessment of the morphology of the valve, for correct positioning of the neochord on the diseased segment , for the final tensioning of the chordae and for the final evaluation of the surgical result. Result and Conclusion: This article is to outline the technical aspects of the transesophageal echocardiography guidance of the NeoChord procedure showing that the procedure can be performed only with a close and continuous interaction between the anesthesiologist and the cardiac surgeon.

  17. PMN-PT single crystal, high-frequency ultrasonic needle transducers for pulsed-wave Doppler application.

    Science.gov (United States)

    Zhou, Qifa; Xu, Xiaochen; Gottlieb, Emanuel J; Sun, Lei; Cannata, Jonathan M; Ameri, Hossein; Humayun, Mark S; Han, Pengdi; Shung, K Kirk

    2007-03-01

    High-frequency needle ultrasound transducers with an aperture size of 0.4 mm were fabricated using lead magnesium niobate-lead titanate (PMN-33% PT) as the active piezoelectric material. The active element was bonded to a conductive silver particle matching layer and a conductive epoxy backing through direct contact curing. An outer matching layer of parylene was formed by vapor deposition. The active element was housed within a polyimide tube and a 20-gauge needle housing. The magnitude and phase of the electrical impedance of the transducer were 47 omega and -38 degrees, respectively. The measured center frequency and -6 dB fractional bandwidth of the PMN-PT needle transducer were 44 MHz and 45%, respectively. The two-way insertion loss was approximately 15 dB. In vivo high-frequency, pulsed-wave Doppler patterns of blood flow in the posterior portion and in vitro ultrasonic backscatter microscope (UBM) images of the rabbit eye were obtained with the 44-MHz needle transducer.

  18. Tissue Doppler echocardiography reveals distinct patterns of impaired myocardial velocities in different degrees of coronary artery disease

    DEFF Research Database (Denmark)

    Hoffmann, Soren; Mogelvang, Rasmus; Olsen, Niels Thue

    2010-01-01

    Aim To determine how the left ventricular wall motion assessed by echocardiographic Tissue Doppler Imaging (TDI) is affected by increasing severity of coronary artery disease (CAD) among patients with stable angina pectoris and preserved ejection fraction. METHODS AND RESULTS: This study comprise...

  19. A Generalized Wave Diagram for Moving Sources

    Science.gov (United States)

    Alt, Robert; Wiley, Sam

    2004-12-01

    Many introductory physics texts1-5 accompany the discussion of the Doppler effect and the formation of shock waves with diagrams illustrating the effect of a source moving through an elastic medium. Typically these diagrams consist of a series of equally spaced dots, representing the location of the source at different times. These are surrounded by a series of successively smaller circles representing wave fronts (see Fig. 1). While such a diagram provides a clear illustration of the shock wave produced by a source moving at a speed greater than the wave speed, and also the resultant pattern when the source speed is less than the wave speed (the Doppler effect), the texts do not often show the details of the construction. As a result, the key connection between the relative distance traveled by the source and the distance traveled by the wave is not explicitly made. In this paper we describe an approach emphasizing this connection that we have found to be a useful classroom supplement to the usual text presentation. As shown in Fig. 2 and Fig. 3, the Doppler effect and the shock wave can be illustrated by diagrams generated by the construction that follows.

  20. Right heart function in impaired left ventricular diastolic function: 2D speckle tracking echocardiography-based and Doppler tissue imaging-based analysis of right atrial and ventricular function.

    Science.gov (United States)

    Brand, Anna; Bathe, Marny; Oertelt-Prigione, Sabine; Seeland, Ute; Rücke, Mirjam; Regitz-Zagrosek, Vera; Stangl, Karl; Knebel, Fabian; Stangl, Verena; Dreger, Henryk

    2018-01-01

    The aim of our study was to describe right atrial (RA) and right ventricular (RV) function, assessed by Doppler tissue imaging and 2D speckle tracking echocardiography (2DSTE), in women with signs of early impaired left ventricular diastolic function (DD). In a cross-sectional trial, standard parameters of diastolic and right heart function were investigated in 438 women of the Berlin Female Risk Evaluation (BEFRI) study. In a subset of women, average peak systolic RA strain (RAS), as well as the average peak systolic RV strain of the free wall (RVS free wall) and of all RV segments (average RV strain; RVS Avg), was analyzed using 2DSTE. Compared to women with normal diastolic function (DD0), RAS, RVS free wall and RVS Avg were significantly reduced in DD (43.1% ± 11.9%, -26.7% ± 5.6%, and -23.3% ± 3.5% in DD0; vs 35.1% ± 10.4%, -23.9% ± 5.5%, and -20.6% ± 3.8% in DD; P right heart function is significantly altered in DD. DTI as well as 2DSTE constitute sensitive echocardiographic tools that enable the diagnosis of impaired right heart mechanics in early-staged DD. © 2017 Wiley Periodicals, Inc.

  1. Frequency shift of the Bragg and Non-Bragg backscattering from periodic water wave

    Science.gov (United States)

    Wen, Biyang; Li, Ke

    2016-08-01

    Doppler effect is used to measure the relative speed of a moving target with respect to the radar, and is also used to interpret the frequency shift of the backscattering from the ocean wave according to the water-wave phase velocity. The widely known relationship between the Doppler shift and the water-wave phase velocity was deduced from the scattering measurements data collected from actual sea surface, and has not been verified under man-made conditions. Here we show that this ob- served frequency shift of the scattering data from the Bragg and Non-Bragg water wave is not the Doppler shift corresponding to the water-wave phase velocity as commonly believed, but is the water-wave frequency and its integral multiple frequency. The power spectrum of the backscatter from the periodic water wave consists of serials discrete peaks, which is equally spaced by water wave frequency. Only when the water-wave length is the integer multiples of the Bragg wave, and the radar range resolution is infinite, does the frequency shift of the backscattering mathematically equal the Doppler shift according to the water-wave phase velocity.

  2. Systolic pulmonary artery pressure assessed during routine exercise Doppler echocardiography: insights of a real-world setting in patients with elevated pulmonary pressures.

    Science.gov (United States)

    Korff, Susanne; Enders-Gier, Patricia; Uhlmann, Lorenz; Aurich, Matthias; Greiner, Sebastian; Hirschberg, Kristof; Katus, Hugo A; Mereles, Derliz

    2018-03-19

    Pulmonary hypertension is a marker of disease severity. Exercise Doppler echocardiography (EDE) has proven to be feasible and reliable to assess pulmonary pressure. Increase in systolic pulmonary artery pressure (sPAP) has diagnostic and prognostic value in controlled studies. However, its value when assessed during routine examination in patients with cardiopulmonary diseases and resting sPAP > 35 mmHg is not clearly defined. Clinical documentation and offline reevaluation of digitally stored EDE examinations of patients with appropriate clinical indications for EDE were analyzed. N = 278 patients with sPAP at rest > 35 mmHg met inclusion criteria. One patient was lost to follow-up. Mean age of patients was 72 ± 10 years, 178 (64%) of the study population were men. There were no relevant differences among survivors and non-survivors concerning comorbidities. Exercise performance (3.6 ± 1.2 vs. 4.9 ± 1.4 MET, p  45 mm (HR = 2.58, p  42 mmHg (HR = 1.94, p = 0.010) and ΔsPAP increase ≥ 0.23 mmHg/Watt (HF = 1.92, p = 0.010). After multivariate analysis, NYHA functional class III (HR = 2.35, p < 0.001), LA diameter (HR = 2.28, p = 0.003) and sPAP increase ≥ 0.23 mmHg/Watt (HF = 2.19, p = 0.002) remained significant predictors of mortality, whereas a double product (HR = 0.42, p = 0.005) was associated with better prognosis. sPAP assessment during routine EDE provides relevant prognostic information comparable to findings in studies in selected populations. A higher sPAP increase at lower exercise performance shows significant association with increased of mortality.

  3. Doppler reflectometry for the investigation of poloidally propagating density perturbations

    International Nuclear Information System (INIS)

    Hirsch, M.; Baldzuhn, J.; Kurzan, B.; Holzhauer, E.

    1999-01-01

    A modification of microwave reflectometry is discussed where the direction of observation is tilted with respect to the normal onto the reflecting surface. The experiment is similar to scattering where a finite resolution in k-space exists but keeps the radial localization of reflectometry. The observed poloidal wavenumber is chosen by Bragg's condition via the tilt angle and the resolution in k-space is determined by the antenna pattern. From the Doppler shift of the reflected wave the poloidal propagation velocity of density perturbations is obtained. The diagnostic capabilities of Doppler reflectometry are investigated using full wave code calculations. The method offers the possibility to observe changes in the poloidal propagation velocity of density perturbations and their radial shear with a temporal resolution of about 10μs. (authors)

  4. Propagation of gravity waves and spread F in the low-latitude ionosphere over Tucumán, Argentina, by continuous Doppler sounding: First results

    Czech Academy of Sciences Publication Activity Database

    Chum, Jaroslav; Bonomi, F. A. M.; Fišer, Jiří; Cabrera, M. A.; Ezquer, R. G.; Burešová, Dalia; Laštovička, Jan; Baše, Jiří; Hruška, František; Molina, M. G.; Ise, J. E.; Cangemi, J. I.; Šindelářová, Tereza

    2014-01-01

    Roč. 119, č. 8 (2014), s. 6954-6965 ISSN 2169-9380 R&D Projects: GA ČR(CZ) GAP209/12/2440; GA ČR GP13-09778P Institutional support: RVO:68378289 Keywords : low latitude ionosphere * Ionospheric irregularities * equatorial spread F * gravity waves * scintillation * remote sensing * Doppler sounding Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 3.426, year: 2014 http://onlinelibrary.wiley.com/doi/10.1002/2014JA020184/abstract

  5. Prevalence of Rheumatic Heart Disease in a Public School of Belo Horizonte

    Directory of Open Access Journals (Sweden)

    Lavinia Pimentel Miranda

    2014-08-01

    Full Text Available Background: Previous studies indicate that compared with physical examination, Doppler echocardiography identifies a larger number of cases of rheumatic heart disease in apparently healthy individuals. Objectives: To determine the prevalence of rheumatic heart disease among students in a public school of Belo Horizonte by clinical evaluation and Doppler echocardiography. Methods: This was a cross-sectional study conducted with 267 randomly selected school students aged between 6 and 16 years. students underwent anamnesis and physical examination with the purpose of establishing criteria for the diagnosis of rheumatic fever. They were all subjected to Doppler echocardiography using a portable machine. Those who exhibited nonphysiological mitral regurgitation (MR and/or aortic regurgitation (AR were referred to the Doppler echocardiography laboratory of the Hospital das Clínicas of the Universidade Federal of Minas Gerais (HC-UFMG to undergo a second Doppler echocardiography examination. According to the findings, the cases of rheumatic heart disease were classified as definitive, probable, or possible. Results: Of the 267 students, 1 (0.37% had a clinical history compatible with the diagnosis of acute rheumatic fever (ARF and portable Doppler echocardiography indicated nonphysiological MR and/or AR in 25 (9.4%. Of these, 16 (6% underwent Doppler echocardiography at HC-UFMG. The results showed definitive rheumatic heart disease in 1 student, probable rheumatic heart disease in 3 students, and possible rheumatic heart disease in 1 student. Conclusion: In the population under study, the prevalence of cases compatible with rheumatic involvement was 5 times higher on Doppler echocardiography (18.7/1000; 95% CI 6.9/1000-41.0/1000 than on clinical evaluation (3.7/1000-95% CI.

  6. Determination of Minimum Data Set (MSD) in Echocardiography Reporting System to Exchange with Iran's Electronic Health Record (EHR) System.

    Science.gov (United States)

    Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh

    2016-04-01

    Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. to determine the minimum data set of echocardiography reporting system to exchange with Iran's electronic health record (EHR) system. First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients' records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. The highest degree of consensus was found for the following MDSs: patient's name and family name (5), accepting doctor's name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran's electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider.

  7. High prevalence of rheumatic heart disease detected by echocardiography in school children.

    Science.gov (United States)

    Bhaya, Maneesha; Panwar, Sadik; Beniwal, Rajesh; Panwar, Raja Babu

    2010-04-01

    It is fairly easy to detect advanced valve lesions of established rheumatic heart disease by echocardiography in the clinically identified cases of rheumatic heart disease. However, to diagnose a subclinical case of rheumatic heart disease, no uniform set of echocardiographic criteria exist. Moderate thickening of valve leaflets is considered an indicator of established rheumatic heart disease. World Health Organization criteria for diagnosing probable rheumatic heart disease are more sensitive and are based on the detection of significant regurgitation of mitral and/or aortic valves by color Doppler. We attempted diagnosing RHD in school children in Bikaner city by cardiac ultrasound. The stratified cluster sampling technique was employed to identify 31 random clusters in the coeducational schools of Bikaner city. We selected 1059 school children aged 6-15 years from these schools. An experienced operator did careful cardiac auscultation and echocardiographic study. A second expert confirmed the echocardiographic findings. The prevalence of lesions suggestive of rheumatic heart disease by echocardiography was 51 per 1,000 (denominator = 1059; 95% CI: 38-64 per 1,000). We were able to clinically diagnose RHD in one child. None of these children or their parents having echocardiographic evidence of RHD could provide a positive history of acute rheumatic fever. By echocardiographic screening, we found a high prevalence of rheumatic heart disease in the surveyed population. Clinical auscultation had much lower diagnostic efficacy.

  8. Direct measurement of Lorentz transformation with Doppler effects

    Science.gov (United States)

    Chen, Shao-Guang

    For space science and astronomy the fundamentality of one-way velocity of light (OWVL) is selfevident. The measurement of OWVL (distance/interval) and the clock synchronization with light-signal transfer make a logical circulation. This means that OWVL could not be directly measured but only come indirectly from astronomical method (Romer's Io eclipse and Bradley's sidereal aberration), furthermore, the light-year by definitional OWVL and the trigonometry distance with AU are also un-measurable. For to solve this problem two methods of clock synchronization were proposed: The direct method is that at one end of dual-speed transmissionline with single clock measure the arriving-time difference of longitudinal wave and transverse wave or ordinary light and extraordinary light, again to calculate the collective sending-time of two wave with Yang's /shear elastic-modulus ratio (E/k) or extraordinary/ordinary light refractive-index ratio (ne/no), which work as one earthquake-station with single clock measures first-shake time and the distance to epicenter; The indirect method is that the one-way wavelength l is measured by dual-counters Ca and Cb and computer's real-time operation of reading difference (Nb - Na) of two counters, the frequency f is also simultaneously measured, then l f is just OWVL. Therefore, with classical Newtonian mechanics and ether wave optics, OWVL can be measured in the Galileo coordinate system with an isotropic length unit (1889 international meter definition). Without any hypotheses special relativity can entirely establish on the metrical results. When a certain wavelength l is defined as length unit, foregoing measurement of one-way wavelength l will become as the measurement of rod's length. Let a rigidity-rod connecting Ca and Cb moves relative to lamp-house with velocity v, rod's length L = (Nb - Na) l will change follow v by known Doppler effect, i.e., L(q) =L0 (1+ (v/c) cos q), where L0 is the proper length when v= 0, v• r = v cos q

  9. Design And Analysis Of Doppler Radar-Based Vehicle Speed Detection

    Directory of Open Access Journals (Sweden)

    Su Myat Paing

    2015-08-01

    Full Text Available The most unwanted thing to happen to a road user is road accident. Most of the fatal accidents occur due to over speeding. Faster vehicles are more prone to accident than the slower one. Among the various methods for detecting speed of the vehicle object detection systems based on Radar have been replaced for about a century for various purposes like detection of aircrafts spacecraft ships navigation reading weather formations and terrain mapping. The essential feature in adaptive vehicle activated sign systems is the accurate measurement of a vehicles velocity. The velocities of the vehicles are acquired from a continuous wave Doppler radar. A very low amount of power is consumed in this system and only batteries can use to operate. The system works on the principle of Doppler Effect by detecting the Doppler shift in microwaves reflected from a moving object. Since the output of the sensor is sinusoidal wave with very small amplitude and needs to be amplified with the help of the amplifier before further processing. The purpose to calculate and display the speed on LCD is performed by the microcontroller.

  10. Acute myocarditis with normal wall motion detected with 2D speckle tracking echocardiography

    Directory of Open Access Journals (Sweden)

    Thomas Sturmberger

    2016-05-01

    Full Text Available We present the case of a 26-year-old male with acute tonsillitis who was referred for coronary angiography because of chest pain, elevated cardiac biomarkers, and biphasic T waves. The patient had no cardiovascular risk factors. Echocardiography showed no wall motion abnormalities and no pericardial effusion. 2D speckle tracking revealed distinct decreased regional peak longitudinal systolic strain in the lateral and posterior walls. Ischemic disease was extremely unlikely in view of his young age, negative family history regarding coronary artery disease, and lack of regional wall motion abnormalities on the conventional 2D echocardiogram. Coronary angiography was deferred as myocarditis was suspected. To confirm the diagnosis, cardiac magnetic resonance tomography (MRT was performed, showing subepicardial delayed hyperenhancement in the lateral and posterior walls correlating closely with the strain pattern obtained by 2D speckle tracking echocardiography. With a working diagnosis of acute myocarditis associated with acute tonsillitis, we prescribed antibiotics and nonsteroidal anti-inflammatory drugs. The patient’s clinical signs resolved along with normalization of serum creatine kinase (CK levels, and the patient was discharged on the third day after admission. Learning points: • Acute myocarditis can mimic acute coronary syndromes. • Conventional 2D echocardiography lacks specific features for detection of subtle regional wall motion abnormalities. • 2D speckle tracking expands the scope of echocardiography in identifying myocardial dysfunction derived from edema in acute myocarditis.

  11. The Value of Contrast Echocardiography

    Directory of Open Access Journals (Sweden)

    Shannon C. Treiber

    2016-01-01

    Full Text Available Purpose: There is much evidence-based research proving the effectiveness of contrast echocardiography, but there are still questions and concerns about its specific uses. This study tested the effectiveness of contrast echocardiography in defining the left ventricular endocardial border. Methods: From 30 patients, a total of 60 echocardiograms –– 30 with and 30 without use of contrast –– were retrospectively reviewed by four blinded cardiologists with advanced training in echocardiography. No single cardiologist reviewed contrast and noncontrast images of the same patient. Each set of 30 echocardiograms was then studied for wall-motion scoring. Visualization of left ventricular wall segments and a global visualization confidence level of interpretation were recorded. Results: Of all wall segments (N = 510, 91% were visualized in echocardiograms with use of contrast, whereas 75% of the walls were visualized in echocardiograms without contrast (P < 0.001. Of 30 examinations, 17 contrast echocardiograms were read with high confidence compared to 6 without contrast use (P = 0.004. The number of walls visualized with contrast was increased in 18 patients (60%, whereas noncontrast echocardiograms yielded more visualized walls in 6 patients (20%, P = 0.002. Conclusions: This study demonstrates that contrast is valuable to echocardiographic imaging. Its use should be supported throughout echocardiography clinics and encouraged in certain patients for whom resting and stress echocardiography results without contrast often prove uninterpretable.

  12. Transesophageal echocardiography in patients with cryptogenic cerebral ischemia

    Directory of Open Access Journals (Sweden)

    Dreger Henryk

    2009-03-01

    Full Text Available Abstract Background In about one third of all patients with cerebral ischemia, no definite cause can be identified (cryptogenic stroke. In many patients with initially suspected cryptogenic stroke, however, a cardiogenic etiology can eventually be determined. Hence, the aim of this study was to describe the prevalence of abnormal echocardiographic findings in a large number of these patients. Method Patients with cryptogenic cerebral ischemia (ischemic stroke, IS, and transient ischemic attack, TIA were included. The initial work-up included a neurological examination, EEG, cCT, cMRT, 12-lead ECG, Holter-ECG, Doppler ultrasound of the extracranial arteries, and transthoracic echocardiography. A multiplane transeophageal echocardiography (TEE, including i.v. contrast medium application [Echovist], Valsalva maneuver was performed in all patients Results 702 consecutive patients (380 male, 383 IS, 319 TIA, age 18–90 years were included. In 52.6% of all patients, TEE examination revealed relevant findings. Overall, the most common findings in all patients were: patent foramen ovale (21.7%, previously undiagnosed valvular disease (15.8%, aortic plaques, aortic valve sclerosis, atrial septal aneurysms, regional myocardial dyskinesia, dilated left atrium and atrial septal defects. Older patients (> 55 years, n = 291 and patients with IS had more relevant echocardiographic findings than younger patients or patients with TIA, respectively (p = 0.002, p = 0.003. The prevalence rates of PFO or ASD were higher in younger patients (PFO: 26.8% vs. 18.0%, p = 0.005, ASD: 9.6% vs. 4.9%, p = 0.014. Conclusion A TEE examination in cryptogenic stroke reveals contributing cardiogenic factors in about half of all patients. Younger patients had a higher prevalence of PFO, whereas older patients had more frequently atherosclerotic findings. Therefore, TEE examinations seem indicated in all patients with cryptogenic stroke – irrespective of age – because of

  13. Prediction of wall motion improvement after coronary revascularization in patients with postmyocardial infarction. Diagnostic value of dobutamine stress echocardiography and myocardial contrast echocardiography

    International Nuclear Information System (INIS)

    Waku, Sachiko; Ohkubo, Tomoyuki; Takada, Kiyoshi; Ishihara, Tadashi; Ohsawa, Nakaaki; Adachi, Itaru; Narabayashi, Isamu

    1997-01-01

    The diagnostic value of dobutamine stress echocardiography, myocardial contrast echocardiography and dipyridamole stress thallium-201 single photon emission computed tomography (SPECT) for predicting recovery of wall motion abnormality after revascularization was evaluated in 13 patients with postmyocardial infarction. Seventeen segments showed severe wall motion abnormalities before revascularization. Nine segments which had relatively good Tl uptake on delayed SPECT images despite severely abnormal wall motion were opacified during myocardial contrast echocardiography, and showed improved wall motion after revascularization. In contrast, three segments which had poor Tl uptake and severely abnormal wall motion were not opacified during myocardial contrast echocardiography, and showed no improvement in wall motion during dobutamine stress echocardiography and after revascularization. The following three findings were assumed to be signs of myocardial viability: good Tl uptake on delayed SPECT images, improved wall motion by dobutamine stress echocardiography, and positive opacification of the myocardium by myocardiai contrast echocardiography. Myocardial contrast echocardiography had the highest sensitivity (100%) and negative predictive value (100%). Delayed SPECT images had the highest specificity (100%) and positive predictive value (100%). Dobutamine stress echocardiography had a sensitivity of 83.0%, specificity of 80.0%, positive predictive value of 90.9%, and negative predictive value of 66.7%, respectively. Myocardial contrast echocardiography showed the lowest specificity (60.0%). The techniques of dobutamine stress echocardiography and SPECT, though noninvasive, may underestimate wall motion improvement after revascularization. Further examination by myocardial contrast echocardiography is recommended to assess myocardial viability for determining the indications for coronary revascularization in spite of its invasiveness. (author)

  14. Fetal Echocardiography/Your Unborn Baby's Heart

    Science.gov (United States)

    ... Artery Disease Venous Thromboembolism Aortic Aneurysm More Fetal Echocardiography / Your Unborn Baby's Heart Updated:Oct 6,2016 ... Your Risk • Symptoms & Diagnosis Introduction Common Tests Fetal Echocardiography/Your Unborn Baby's Heart - Fetal Echocardiogram Test - Detection ...

  15. Sub-Doppler cooling in reduced-period optical lattice geometries

    International Nuclear Information System (INIS)

    Berman, P.R.; Raithel, G.; Zhang, R.; Malinovsky, V.S.

    2005-01-01

    It is shown that sub-Doppler cooling occurs in an atom-field geometry that can lead to reduced-period optical lattices. Four optical fields are combined to produce a 'standing wave' Raman field that drives transitions between two ground state sublevels. In contrast to conventional Sisyphus cooling, sub-Doppler cooling to zero velocity occurs when all fields are polarized in the same direction. Solutions are obtained using both semiclassical and quantum Monte Carlo methods in the case of exact two-photon resonance. The connection of the results with conventional Sisyphus cooling is established using a dressed state basis

  16. Frequency of cardiac defects among children at echocardiography centre in a teaching hospital

    International Nuclear Information System (INIS)

    Malik, A.S.; Majeed, R.; Channer, M.S.; Saleem, M.I.

    2010-01-01

    Objective: To assess frequency of cardiac defects among children from birth to 12 years of age on each Methodology: A cross sectional study was conducted at echocardiography centre in coronary care unit at Bahawal Victoria Hby Paediatric Transthoracic echo probe; 2-D colour Doppler, Acuson CV-70 and Niemo-30 echocardiography machines. Mothers of children with cardiac defects were interviewed at the echocardiography centre. Variables included were A- Muscular plus Vascular defects; B- Valvular defects; C-Pericardial effusion; D- Dextrocardia and E- Congestive cardiac failure. History of children for sore throat followed by joint pains; history of mothers for drug intake (antihypertensive, antipyretic, anti-emetic, hypoglycaemic) as well as chronic diseases (diabetes mellitus, hypertension, anaemia) during pregnancy were surveyed. Parity of mothers, their cousin marriages, and family socio-economic status was also inquired. The results were tabulated, analyzed and finally subjected to suitable test of significant (SR of proportion) to find out statistical significant if any. Results: It was found that out of 150 patients, 76 (50.66%) were suffering from Cardiac muscular and Vascular defects, 61 (40.66%) Valvular defects, 7 (4.66%) Pericardial effusion, 2 (1.33%) Dextrocardia and 4 (2.66%) from Congestive Cardiac Failure. According to age, 54 (36%) were from birth to 3 years of age and 51 (34%) from 10 to 12 years. There was history of Rheumatic fever among 45 (30%) children. There were 106 (70.6%) children from lower socio-economic class and 79 (52.6%) parents had history of cousin marriages. Conclusion: Frequency of cardiac defects was more in children of male sex, lower socio-economic group, from birth to three years age and children from primipara mothers in our specified locality. Rheumatic fever, cousin's marriage, and prescribed drugs intake during pregnancy (for metabolic and hormonal disorders) were other contributors to cardiac defects. (author)

  17. Christian Andreas Doppler--the man and his legacy.

    Science.gov (United States)

    Coman, I M

    2005-01-01

    Reminding the life and legacy of the Austrian Scientist who discovered the famous 'Doppler Effect'. C.A. Doppler was born the 29th of November 1803 in Salzburg. After studies in Linz and Vienna, he graduated in mathematics, became assistant at the University and later worked as a professor in Prague. Back to Vienna, he was appointed as professor at the Polytechnic School and --in 1850--as first director of the new Institute of Physics. C.A. Doppler did publish on magnetism, electricity, optics, and astronomy. He remains in the history of science due to the discovery presented (May 25, 1842) at the Royal Bohemian Society of Science entitled "On the colored light of the double stars and certain other stars of the heavens"; the paper described (applied to light) the shift of frequency which bears nowadays his name. The theory was later experimentally proven and--extended for any electromagnetic and acoustic waves--got myriads if applications in astronomy, physics, aviation, meteorology, and health science. Satomura in Japan (1955) published it's first ultrasound vascular application--with successive achievements in the next decades. Doppler ultrasonagraphy became the main noninvasive instrument for functional assesment of heart and vessels.

  18. Doppler sonographic evaluation of ophthalmic arterial flow pattern in hypertensive patients

    International Nuclear Information System (INIS)

    Ryu, Dae Sik; Kim, Young Goo

    1994-01-01

    To compare the Doppler velocity waveform pattern of ophthalmic artery of hypertensive patients with that of normotensive subjects. Doppler velocity waveform was obtained from ophthalmic artery in 45 hypertensive patients and 60 normotensive subjects. Both hypertensives and normotensive subjects were classified according to age into those younger than and those older than 45 years. Doppler indices(pulsatility index(PI), resistance index(RI), the first systolic peak/the second systolic peak(S1/S2), the first systolic peak/diastolic peak(S1/D)) measured in hypertensive patients were compared with normotensive subjects. Among the various doppler indices, only S1/S2 showed significant difference(P < 0.05) between the hypertensive patients and normotensive subjects younger than 45 years. Doppler velocity waveform of hypertensive patients older than 45 years showed no significant difference from that of normotensive subjects with corresponding age. Doppler velocity waveform of ophthalmic artery in hypertensive patients younger than 45 years shows pattern with S2 higher than that of normotensive subjects. High S2 component(reflective-wave) may represent increased vascular impedance due to vasococonstriction of retinal arterioles in hypertensive patients

  19. Safety of ultrasound contrast agents in stress echocardiography.

    Science.gov (United States)

    Gabriel, Ruvin S; Smyth, Yvonne M; Menon, Venu; Klein, Allan L; Grimm, Richard A; Thomas, James D; Sabik, Ellen Mayer

    2008-11-01

    Definity and Optison are perflutren-based ultrasound contrast agents used in echocardiography. United States Food and Drug Administration warnings regarding serious cardiopulmonary reactions and death after Definity administration highlighted the limited safety data in patients who undergo contrast stress echocardiography. From 1998 and 2007, 2,022 patients underwent dobutamine stress echocardiography and 2,764 underwent exercise stress echocardiography with contrast at the Cleveland Clinic. The echocardiographic database, patient records, and the Social Security Death Index were reviewed for the timing and cause of death, severe adverse events, arrhythmias, and symptoms. Complication rates for contrast dobutamine stress echocardiography and exercise stress echocardiography were compared with those in a control group of 5,012 patients matched for test year and type who did not receive contrast. Ninety-five percent of studies were performed in outpatients. There were no differences in the rates of severe adverse events (0.19% vs 0.17%, p = 0.7), death within 24 hours (0% vs 0.04%, p = 0.1), cardiac arrest (0.04% vs 0.04%, p = 0.96), and sustained ventricular tachycardia (0.2% vs 0.1%, p = 0.32) between patients receiving and not receiving intravenous contrast, respectively. In conclusion, severe adverse reactions to intravenous contrast agents during stress echocardiography are uncommon. Contrast use does not add to the baseline risk for severe adverse events in patients who undergo stress echocardiography.

  20. Gravitational wave searches using the DSN (Deep Space Network)

    International Nuclear Information System (INIS)

    Nelson, S.J.; Armstrong, J.W.

    1988-01-01

    The Deep Space Network Doppler spacecraft link is currently the only method available for broadband gravitational wave searches in the 0.01 to 0.001 Hz frequency range. The DSN's role in the worldwide search for gravitational waves is described by first summarizing from the literature current theoretical estimates of gravitational wave strengths and time scales from various astrophysical sources. Current and future detection schemes for ground based and space based detectors are then discussed. Past, present, and future planned or proposed gravitational wave experiments using DSN Doppler tracking are described. Lastly, some major technical challenges to improve gravitational wave sensitivities using the DSN are discussed

  1. Impact of acquisition and interpretation on total inter-observer variability in echocardiography: results from the quality assurance program of the STAAB cohort study.

    Science.gov (United States)

    Morbach, Caroline; Gelbrich, Götz; Breunig, Margret; Tiffe, Theresa; Wagner, Martin; Heuschmann, Peter U; Störk, Stefan

    2018-02-14

    Variability related to image acquisition and interpretation is an important issue of echocardiography in clinical trials. Nevertheless, there is no broadly accepted standard method for quality assessment of echocardiography in clinical research reports. We present analyses based on the echocardiography quality-assurance program of the ongoing STAAB cohort study (characteristics and course of heart failure stages A-B and determinants of progression). In 43 healthy individuals (mean age 50 ± 14 years; 18 females), duplicate echocardiography scans were acquired and mutually interpreted by one of three trained sonographers and an EACVI certified physician, respectively. Acquisition (AcV), interpretation (InV), and inter-observer variability (IOV; i.e., variability between the acquisition-interpretation sequences of two different observers), were determined for selected M-mode, B-mode, and Doppler parameters. We calculated Bland-Altman upper 95% limits of absolute differences, implying that 95% of measurement differences were smaller/equal to the given value: e.g. LV end-diastolic volume (mL): 25.0, 25.0, 27.9; septal e' velocity (cm/s): 3.03, 1.25, 3.58. Further, 90, 85, and 80% upper limits of absolute differences were determined for the respective parameters. Both, acquisition and interpretation, independently and sizably contributed to IOV. As such, separate assessment of AcV and InV is likely to aid in echocardiography training and quality-assurance. Our results further suggest to routinely determine IOV in clinical trials as a comprehensive measure of imaging quality. The derived 95, 90, 85, and 80% upper limits of absolute differences are suggested as reproducibility targets of future studies, thus contributing to the international efforts of standardization in quality-assurance.

  2. Arterial stiffness and wave reflection: sex differences and relationship with left ventricular diastolic function.

    Science.gov (United States)

    Russo, Cesare; Jin, Zhezhen; Palmieri, Vittorio; Homma, Shunichi; Rundek, Tatjana; Elkind, Mitchell S V; Sacco, Ralph L; Di Tullio, Marco R

    2012-08-01

    Increased arterial stiffness and wave reflection have been reported in heart failure with normal ejection fraction (HFNEF) and in asymptomatic left ventricular (LV) diastolic dysfunction, a precursor of HFNEF. It is unclear whether women, who have higher frequency of HFNEF, are more vulnerable than men to the deleterious effects of arterial stiffness on LV diastolic function. We investigated, in a large community-based cohort, whether sex differences exist in the relationship among arterial stiffness, wave reflection, and LV diastolic function. Arterial stiffness and wave reflection were assessed in 983 participants from the Cardiovascular Abnormalities and Brain Lesions study using applanation tonometry. The central pulse pressure/stroke volume index, total arterial compliance, pulse pressure amplification, and augmentation index were used as parameters of arterial stiffness and wave reflection. LV diastolic function was evaluated by 2-dimensional echocardiography and tissue-Doppler imaging. Arterial stiffness and wave reflection were greater in women compared with men, independent of body size and heart rate (all Pfunction in both sexes. Further adjustment for cardiovascular risk factors attenuated these relationships; however, a higher central pulse pressure/stroke volume index predicted LV diastolic dysfunction in women (odds ratio, 1.54; 95% confidence intervals, 1.03 to 2.30) and men (odds ratio, 2.09; 95% confidence interval, 1.30 to 3.39), independent of other risk factors. In conclusion, in our community-based cohort study, higher arterial stiffness was associated with worse LV diastolic function in men and women. Women's higher arterial stiffness, independent of body size, may contribute to their greater susceptibility to develop HFNEF.

  3. The Evolutionary Development of Echocardiography

    Science.gov (United States)

    Maleki, Majid; Esmaeilzadeh, Maryam

    2012-01-01

    Echocardiography is a non-invasive diagnostic technique which provides information on cardiac morphology, function, and hemodynamics. It is the most frequently used cardiovascular diagnostic test only after electrocardiography. In less than five decades, the evolution in this technique has made it the basic part of cardiovascular medicine. Herein, the evolution of various forms of echocardiography is briefly described. PMID:23390327

  4. Implementation of the stress echocardiography in an echocardiographic laboratory

    International Nuclear Information System (INIS)

    Solis Brizuela, Felix

    2013-01-01

    The logistics for the implementation of the stress echocardiography is defined with based on current recommendations, for an echocardiography laboratory. The protocols established to perform the studies and procedures of this diagnostic method are exposed. The elementary conditions to realize with safety the stress echocardiography are established. Recent literature on the evaluation of new echocardiographic techniques is reviewed to determine their usefulness in stress testing. The assessment of stress echocardiography is developed. The stress echocardiography has been the procedure with high sensitivity and specificity for the diagnosis of coronary artery disease [es

  5. Transesophageal echocardiography. 3. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Lambertz, Heinz; Lethen, Harald

    2013-01-01

    The book on transesophageal echocardiography covers the following issues: Development of transesophageal echocardiography, technical advances; indications and contraindication for transesophageal echocardiography; systematic of the medical examination process; cardiac valves and valve prostheses; mitral and aortic valvuloplasty, TAVI and interventional treatment of mitral regurgitation; infectious endocarditis; one-way and effluence disturbances of the left and right ventricle; diseases of the thoracic aorta; undefined right ventricle enlargement; lung embolism, acute infarct complications; TEE during anesthesia and perioperative intensive medicine, cardiac sources of embolism; cardiac tumors, mediastinal lymph nodes; pericardiac diseases; congenital heart diseases in childhood and adulthood; catheter interventions and heart valve reconstruction; surgically corrected congenital cardiac defects; intracavitary versus transesophageal echocardiography; three-dimensional TEE; coronary diagnostics; ischemia and vitality diagnostics.

  6. Practical guidance for the implementation of stress echocardiography.

    Science.gov (United States)

    Suzuki, Kengo; Hirano, Yutaka; Yamada, Hirotsugu; Murata, Mitsushige; Daimon, Masao; Takeuchi, Masaaki; Seo, Yoshihiro; Izumi, Chisato; Akaishi, Makoto

    2018-06-06

    Exercise stress testing has been widely undertaken for the diagnosis of heart diseases. The accurate assessment of clinical conditions can be conducted by comparing the findings obtained from the results of stress echocardiography with the changes in the blood/heart rate and electrocardiograms. Numerous overseas studies have reported the utility of stress echocardiography in diagnosing myocardial ischemia; in Japan, the use of this modality for this purpose was included in the national health insurance reimbursable list in 2012. Nevertheless, stress echocardiography is far from being a widespread practice in Japan. This might be due to insufficient equipment (e.g., ergometers, space for test implementation) at each medical institution, shortage of technicians and sonographers who are well experienced and who are responsible for obtaining images during stress testing. The other possible reasons include the limited evidence available in Japan and the lack of a standardized testing protocol. Further dissemination of the practice of exercise stress echocardiography in this country is deemed necessary to establish satisfactory evidence for the use of stress echocardiography in the Japanese population. To this end, efforts are underway to develop a standardized protocol and report format to be adopted throughout Japan. We here present a guideline created by the Guideline Development Committee of the Japanese Society of Echocardiography that describes safe and effective stress echocardiography protocols and report formats. The readers are encouraged to perform exercise stress echocardiography using the proposed template for consensus document and report attached to this guideline.

  7. Archeological Echocardiography: Digitization and Speckle Tracking Analysis of Archival Echocardiograms in the HyperGEN Study.

    Science.gov (United States)

    Aguilar, Frank G; Selvaraj, Senthil; Martinez, Eva E; Katz, Daniel H; Beussink, Lauren; Kim, Kwang-Youn A; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R; Arnett, Donna K; Shah, Sanjiv J

    2016-03-01

    Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. In the NHLBI HyperGEN study (N = 2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter-/intra-observer agreement was calculated. Accuracy was evaluated in: (1) a separate second study (N = 50) comparing prospective digital strain versus post hoc analog-to-digital strain, and (2) in a third study (N = 95) comparing prospectively obtained TDI e' velocities with post hoc STE e' velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intra-observer agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post hoc STE to prospective digital STE for strain analysis. STE-derived e' velocities correlated with, but systematically underestimated, TDI e' velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β = -2.4 [95% CI -3.6, -1.2]% per 1-SD increase in fasting glucose; P echocardiography, the digitization and speckle tracking analysis of archival echocardiograms, is feasible and generates indices of cardiac mechanics similar to contemporary studies. © 2015, Wiley Periodicals, Inc.

  8. Carcinoid syndrome diagnosed by echocardiography.

    Science.gov (United States)

    Garg, Scot; Bourantas, Christos V; Nair, Rajesh K; Alamgir, Farqad

    2011-02-17

    Right heart failure is a common presentation to both general physicians and cardiologists. Echocardiography is a useful investigation, and usually imaging of the liver is confined to helping estimate the right atrial pressure. We report a case of right heart failure where incidental imaging of the liver architecture during transoesophageal echocardiography helped in establishing the final diagnosis. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  9. Early Detection of Subclinical Uremic Cardiomyopathy Using Two-Dimensional Speckle Tracking Echocardiography.

    Science.gov (United States)

    Hassanin, Noha; Alkemary, Alkhateeb

    2016-04-01

    Overhydration has a deleterious effect on cardio myocytes. This study was designated to evaluate left ventricular (LV) systolic and diastolic dysfunction in patients with various stages of chronic kidney disease (CKD) using conventional, tissue Doppler and two-dimensional speckle tracking echocardiography (2DSTE). Forty controls and 90 CKD patients, aged 49.3 ± 14 years old, were enrolled in the study. Patients were divided into 3 groups depending on their glomerular filtration rate. Group 1 (≥60 mL/min per 1.73 m(2) ), group 2 (≤60 mL/min per 1.73 m(2) ), and group 3 (≤60 mL/min per 1.73 m(2) and on regular dialysis for at least 12 months). Pulsed-Doppler and tissue Doppler studies were used to estimate LV filling pressure E/E'. Using 2DSTE, circumferential, radial, and longitudinal functions of the LV have been measured. LV longitudinal systolic strain, early, and late diastolic strain rates were significantly reduced in CKD patients (-16.9 ± 3.8%, 1.6 ± 0.5%, and 1.3 ± 0.4% in CKD vs. -22.5 ± 0.6%, 2.3 ± 0.2%, and 1.9 ± 0.1% in controls, P < 0.001 for all), and no difference was observed in terms of the circumferential LV functions (-22.4 ± 1.7 vs. -22.5 ± 1.4, P = 0.567). Severity of the kidney dysfunction appears to parallel with the rise of E/E' significantly (P < 0.001). In CKD, although the longitudinal and radial systolic functions were reduced, LV ejection fraction may remain within normal limits due to the preservation of the circumferential functions. Early detection of uremic cardiomyopathy might provide useful information for the risk stratification and decide the proper dialysis therapy in these patients. © 2015, Wiley Periodicals, Inc.

  10. Determination of Minimum Data Set (MSD) in Echocardiography Reporting System to Exchange with Iran’s Electronic Health Record (EHR) System

    Science.gov (United States)

    Mahmoudvand, Zahra; Kamkar, Mehran; Shahmoradi, Leila; Nejad, Ahmadreza Farzaneh

    2016-01-01

    Background: Determination of minimum data set (MDS) in echocardiography reports is necessary for documentation and putting information in a standard way, and leads to the enhancement of electrocardiographic studies through having access to precise and perfect reports and also to the development of a standard database for electrocardiographic reports. Aim: to determine the minimum data set of echocardiography reporting system to exchange with Iran’s electronic health record (EHR) system. Methods: First, a list of minimum data set was prepared after reviewing texts and studying cardiac patients’ records. Then, to determine the content validity of the prepared MDS, the expert views of 10 cardiologists and 10 health information management (HIM) specialists were obtained; to estimate the reliability of the set, test-retest method was employed. Finally, the data were analyzed using SPSS software. Results: The highest degree of consensus was found for the following MDSs: patient’s name and family name (5), accepting doctor’s name and family name, familial death records due to cardiac disorders, the image identification code, mitral valve, aortic valve, tricuspid valve, pulmonary valve, left ventricle, hole, atrium valve, Doppler examination of ventricular and atrial movement models and diagnoses with an average of. Conclusions: To prepare a model of echocardiography reporting system to exchange with EHR system, creation a standard data set is the vital point. Therefore, based on the research findings, the minimum reporting system data to exchange with Iran’s electronic health record system include information on entity, management, medical record, carried-out acts, and the main content of the echocardiography report, which the planners of reporting system should consider. PMID:27147803

  11. Attenuated Vector Tomography -- An Approach to Image Flow Vector Fields with Doppler Ultrasonic Imaging

    International Nuclear Information System (INIS)

    Huang, Qiu; Peng, Qiyu; Huang, Bin; Cheryauka, Arvi; Gullberg, Grant T.

    2008-01-01

    The measurement of flow obtained using continuous wave Doppler ultrasound is formulated as a directional projection of a flow vector field. When a continuous ultrasound wave bounces against a flowing particle, a signal is backscattered. This signal obtains a Doppler frequency shift proportional to the speed of the particle along the ultrasound beam. This occurs for each particle along the beam, giving rise to a Doppler velocity spectrum. The first moment of the spectrum provides the directional projection of the flow along the ultrasound beam. Signals reflected from points further away from the detector will have lower amplitude than signals reflected from points closer to the detector. The effect is very much akin to that modeled by the attenuated Radon transform in emission computed tomography.A least-squares method was adopted to reconstruct a 2D vector field from directional projection measurements. Attenuated projections of only the longitudinal projections of the vector field were simulated. The components of the vector field were reconstructed using the gradient algorithm to minimize a least-squares criterion. This result was compared with the reconstruction of longitudinal projections of the vector field without attenuation. If attenuation is known, the algorithm was able to accurately reconstruct both components of the full vector field from only one set of directional projection measurements. A better reconstruction was obtained with attenuation than without attenuation implying that attenuation provides important information for the reconstruction of flow vector fields.This confirms previous work where we showed that knowledge of the attenuation distribution helps in the reconstruction of MRI diffusion tensor fields from fewer than the required measurements. In the application of ultrasound the attenuation distribution is obtained with pulse wave transmission computed tomography and flow information is obtained with continuous wave Doppler

  12. Recent advances in echocardiography for valvular heart disease.

    Science.gov (United States)

    Hahn, Rebecca

    2015-01-01

    Echocardiography is the imaging modality of choice for the assessment of patients with valvular heart disease. Echocardiographic advancements may have particular impact on the assessment and management of patients with valvular heart disease. This review will summarize the current literature on advancements, such as three-dimensional echocardiography, strain imaging, intracardiac echocardiography, and fusion imaging, in this patient population.

  13. Model experiments on imaging subsurface fracture permeability by pulsed Doppler borehole televiewer; Pulse doppler borehole televiewer ni yoru kiretsu tosuisei hyoka ni kansuru model jikken

    Energy Technology Data Exchange (ETDEWEB)

    Inagaki, Y; Niitsuma, H [Tohoku University, Sendai (Japan). Faculty of Engineering

    1996-05-01

    This paper reports model experiments to evaluate flow rates of fluids passing through a fracture by using a Doppler borehole televiewer (DBHTV). A supersonic transducer disposed on a well axis transmits transmission pulses, and a transducer receives scattered waves generated by particulates in water and waves reflected on a well wall. This signal is applied with time gating to extract only the scattered waves from particulates in the vicinity of the well wall. Deriving spectra in the recorded Doppler signal obtains flow velocity components in the direction of the well radius. A model was made with a polyvinylchloride pipe with a diameter of 14.6 cm to simulate a well, to which an aluminum pipe with an inner diameter of 2 mm is connected to be used as a simulated fracture, and mud water is circulated in the pipe. The result of deriving a passed flow volume in this model by integrating flow rate distribution derived by using the above method to a predetermined range in the vicinity of the fracture showed a good proportional relationship with actual flow rate in the simulated fracture. 1 ref., 7 figs.

  14. Clinical significance of a presystolic wave on Doppler examination of the left ventricular outflow tract.

    Science.gov (United States)

    Joshi, Kamal R; Kabirdas, Deepa; Romero-Corral, Abel; Shah, Mahek; Figueredo, Vincent M; Pressman, Gregg S

    2014-11-15

    A presystolic wave (PSW) is commonly seen on Doppler examination of the left ventricular outflow tract (LVOT), but is little studied. We conducted a retrospective study to assess the prevalence of the PSW, correlations with various Doppler parameters, and its clinical significance. Two hundred echocardiograms, 100 with ejection fraction (EF) >55% and 100 with EF <45%, were reviewed. Mitral inflow velocities, septal annular velocities, LVOT, and PSW velocities were measured. Major adverse cardiovascular events (MACE [death, heart failure hospitalization, atrial fibrillation, and stroke]) were compared between those with and without a PSW, in both EF groups. Mean age was 58 ± 15 years; 56% were men and 69% were African-American. PSW prevalence was similar between normal (68%) and reduced EF groups (62%). However, its velocity was less in the low EF group (37 ± 10 vs 48 ± 16 cm/s, p <0.0001). In subjects with normal EF PSW velocity correlated with mitral A velocity (rho = 0.43, p = 0.0003). In subjects with reduced EF the association with A velocity was not significant (rho = 0.22, p = 0.09), but there was a significant association with annular a' velocity (rho = 0.38, p = 0.002). Over a mean follow-up of 1.7 ± 0.3 years, 57 subjects (28%) experienced MACE. Those without a PSW had more MACE (39% vs 23%, p = 0.02); PSW absence remained predictive of MACE after adjustment for multiple variables, especially in patients with reduced EF. In conclusion, PSW is common in the LVOT. Its presence and magnitude are associated with measures of atrial contraction. Its absence is associated with increased rates of adverse events, especially in patients with low EF. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Multiple cardiac complications after adjuvant therapy for breast cancer: the importance of echocardiography. A case report and review of the literature.

    Science.gov (United States)

    Gurghean, Adriana Luminita; Savulescu-Fiedler, Ilinca; Mihailescu, Anca

    2017-01-31

    Cardiovascular complications induced by adjuvant cancer therapies may become symptomatic after many years, being responsible for increased morbidity and mortality in long-term survivors. We report a case of a 54-year old female admitted for severe heart failure induced by myocardial and valvular damage after postoperative adjuvant therapy for left breast cancer 6 years ago. Her recent history revealed nonST elevation myocardial infarction in the absence of significant cardiovascular risk factors. Transthoracic echocardiography, tissue Doppler imaging and speckle-tracking imaging revealed severe biventricular systolic dysfunction, severe mitral and tricuspid regurgitation and severe pulmonary hypertension.

  16. The impact of left ventricular preload reduction on cardiac pulsed doppler indices during hemodialysis and its relation to intra-dialysis hypotension: A pulsed doppler study

    International Nuclear Information System (INIS)

    Alarrayed, Sameer; Garadah Taysir Said; Alawdi, Abdulhai Ali

    2009-01-01

    Fluid status in the body plays an important role on left ventricular (LV) filling in patients with end-stage renal disease (ESRD) on regular hemodialysis (HD), and plays a role in intra-dialysis hemodynamic derangement. Fifty-two patients with ESRD on regular HD, including 34 males with a mean age of 45.5 +- 13 years (range 18-72 years), were studied. All patients underwent Echo-pulsed Doppler study before and immediately after a HD session. The Echo Doppler indices noted were: LV cavity dimension and wall thickness, LV ejection fraction (LVEF%), trans-mitral early diastolic filling velocity (E wave), atrial filling diastolic velocity (A wave), E/A ratio, Deceleration Time (DT) of E wave, Isovolumic relaxation time (IVRT), Aortic Velocity Integral (AVI) and Inferior Vena Cava Diameter (VCD) at expiration. Patients were divided into two groups according to the amount of net ultra filtrate loss after HD. Group I comprised of 25 patients with fluid loss of 2 liters. During the HD session, each patient was observed for the development of acute clinical events such as arterial hypotension (systolic BP less than 90 mmHg), chest pain and arrhythmias. There was a significant difference between the two groups in the mean values, pre- and post- HD, of reduction of E wave velocity (p < 0.01), the reduction of E/A ratio (p< 0.05), the increment in DT of E wave (p< 0.05), the reduction in AVI (p< 0.01) and the reduction of VCD (p< 0.05). There was no significant difference between the groups in the reduction of A wave velocity and the reduction of IVRT. Among the study patients, 11 (21%) developed systolic hypo-tension during HD. The pre-dialysis mean values of E/A ratio and DT of E wave in patients who developed hypotension compared to those who did not was 0.7 +- 0.2 vs 1.1 +- 0.2.1 (p< 0.001) and 246 +- 40 vs 224 +- 34 msec (p< 0.05), respectively. Our study suggests that preload reduction in patients with ESRD on regular HD is directly proportional to the reduction of left

  17. Transition from Spirals to Defect-Mediated Turbulence Driven by a Doppler Instability

    International Nuclear Information System (INIS)

    Ouyang, Qi; Swinney, Harry L.; Li, Ge

    2000-01-01

    A transition from rotating chemical spirals to turbulence is observed in experiments on the Belousov-Zhabotinsky reaction. The transition occurs when the waves near the spiral tip spontaneously break, generating defects. Measurements reveal that this defect-mediated turbulence is caused by the Doppler effect on the traveling waves. The observations are in good accord with numerical simulations and theory. (c) 2000 The American Physical Society

  18. Fetal Echocardiography and Indications

    Directory of Open Access Journals (Sweden)

    Melih Atahan Güven

    2008-09-01

    Full Text Available Congenital heart diseases are encountered in 0.8% of live births and are among the most frequently diagnosed malformations. At least half of these anomalies end up with death or require surgical interventions and are responsible for 30% of the perinatal mortality. Fetal echocardiography is the sum of knowledge, skill and orientation rather than knowing the embryologic details of the fetal heart. The purpose of fetal echocardiography is to document the presence of normal fetal cardiac anatomy and rhythm in high risk group and to define the anomaly and arrhythmia if present. A certain sequence should be followed during the evaluation of fetal heart. Sequential segmental analysis (SSA and basic definition terminology made it possible to determine a lot of complex cardiac anomalies during prenatal period. By the end of 1970’s, Shinebourne started using sequential segmental analysis for fetal cardiac evaluation and today, prenatal diagnosis of congenital heart disease is possible without any confusion. In this manner, whole fetal heart can be evaluated as the relation of three segments (atria, ventricles and the great arteries with each other, irrelevant of complexity of a possible cardiac anomaly. Presence of increased nuchal thickness during early gestation and abnormal four-chamber-view during ultrasonography by the obstetrician presents a clear indication for fetal echocardiography,however, one should keep in mind that 80-90% of the babies born with a congenital heart disease do not have a familial or maternal risk factor. In addition, it should be remembered that expectant mothers with diabetes mellitus pose an indication for fetal echocardiography.

  19. Experimental verification of the inverse Doppler effect in negative-index material

    Science.gov (United States)

    Feng, Lie; Chen, Jiabi; Wang, Yan; Geng, Tao; Zhuang, Songlin

    2010-10-01

    μResearch of negative-index material (NIM) is a very hot developing research field in recent years. NIM is also called left-handed material (LHM), in which the electric field [see manuscript], the magnetic field [see manuscript] and the wave vector [see manuscript] are not composed of a set of right-handed coordinates but a set of left-handed coordinates. Thus the action of electromagnetic waves in both left-handed material and right-handed material is just the opposite, for instance, the negative refraction phenomenon, the inverse Doppler effect and so on. Here we report the explicit result of the inverse Doppler effect through a photonic crystal (PC) prism at 10.6m wavelength for the first time, and the result we get from the experiment is much similar to the theoretical analysis we have deduced before. During the experiment, the CO2 laser is used as a light source, and the PC prism is used as a sample, which can move a tiny distance (1mm) uniformly with a translating stage. Based on the method of optical heterodyne, we let the emergent light from the output surface of PC prism and the reference light from light source interfere at the surface of the detector. When the translating stage moves towards the detector, the optical paths in the PC prism will be changed, and then the Doppler frequency shift will be generated. Though several different samples have been tested repeatedly, the results we get are extraordinarily similar. So we can be sure that the inverse Doppler effect really exists in the NIM at optical frequencies. To our best knowledge, this is the only experimental verification of the inverse Doppler effect in the NIM at optical frequencies at home and aboard.

  20. Endocarditis : Effects of routine echocardiography during Gram-positive bacteraemia

    NARCIS (Netherlands)

    Vos, F J; Bleeker-Rovers, C P; Sturm, P D; Krabbe, P F M; van Dijk, A P J; Oyen, W J G; Kullberg, B J

    2011-01-01

    BACKGROUND: Despite firm recommendations to perform echocardiography in high-risk patients with Gram-positive bacteraemia, routine echocardiography is not embedded in daily practice in many settings. The aim of this study was to evaluate whether a regime including routine echocardiography results in

  1. Diastolic left ventricular function in preterm infants with a patent ductus arteriosus: a serial Doppler echocardiography study.

    Science.gov (United States)

    Schmitz, Lothar; Stiller, Brigitte; Koch, Heike; Koehne, Petra; Lange, Peter

    2004-02-01

    In very low birth weight neonates, a left-to-right shunt via persistent ductus arteriosus (PDA) may interact with diastolic left ventricular function, but specific changes of Doppler parameters have yet to be reported. In a serial transmitral Doppler study, we investigated the impact of a PDA on diastolic function parameters. Twenty-two patients with and without PDA were examined on day 3.8+/-1 and day 14+/-2 after birth. By the first examination, 13 out of 22 patients had a PDA; by the second examination, the number was still 8 out of 22. Peak early and atrial flow velocities (44.8+/-15 and 50.1+/-13 cm/s, respectively) were higher (pclosure of the PDA. When premature infants with a PDA experience a preload challenge, early and atrial peak velocities increase and IVRT shortens significantly. This coincidence of elevated transvalvular pressure differences and decreased IVRT in neonates with immature diastolic function can best be explained as a result of left atrial pressure elevation. Consequently, pulmonary venous pressure must be elevated, with its inherent effect on pulmonary capillary physiology. Thus, the monitoring of left ventricular diastolic function adds significant information to the care of preterm infants with a PDA.

  2. Implementing a Continuous Quality Improvement Program in a High-Volume Clinical Echocardiography Laboratory: Improving Care for Patients With Aortic Stenosis.

    Science.gov (United States)

    Samad, Zainab; Minter, Stephanie; Armour, Alicia; Tinnemore, Amanda; Sivak, Joseph A; Sedberry, Brenda; Strub, Karen; Horan, Seanna M; Harrison, J Kevin; Kisslo, Joseph; Douglas, Pamela S; Velazquez, Eric J

    2016-03-01

    The management of aortic stenosis rests on accurate echocardiographic diagnosis. Hence, it was chosen as a test case to examine the utility of continuous quality improvement (CQI) approaches to increase echocardiographic data accuracy and reliability. A novel, multistep CQI program was designed and prospectively used to investigate whether it could minimize the difference in aortic valve mean gradients reported by echocardiography when compared with cardiac catheterization. The Duke Echo Laboratory compiled a multidisciplinary CQI team including 4 senior sonographers and MD faculty to develop a mapped CQI process that incorporated Intersocietal Accreditation Commission standards. Quarterly, the CQI team reviewed all moderate- or greater-severity aortic stenosis echocardiography studies with concomitant catheterization data, and deidentified individual and group results were shared at meetings attended by cardiologists and sonographers. After review of 2011 data, the CQI team proposed specific amendments implemented over 2012: the use of nontraditional imaging and Doppler windows as well as evaluation of aortic gradients by a second sonographer. The primary outcome measure was agreement between catheterization- and echocardiography-derived mean gradients calculated by using the coverage probability index with a prespecified acceptable echocardiography-catheterization difference of <10 mm Hg in mean gradient. Between January 2011 and January 2014, 2093 echocardiograms reported moderate or greater aortic stenosis. Among cases with available catheterization data pre- and post-CQI, the coverage probability index increased from 54% to 70% (P=0.03; 98 cases, year 2011; 70 cases, year 2013). The proportion of patients referred for invasive valve hemodynamics decreased from 47% pre-CQI to 19% post-CQI (P<0.001). A laboratory practice pattern that was amenable to reform was identified, and a multistep modification was designed and implemented that produced clinically

  3. Evaluation of Cardiovascular System in Fibromyalgia Syndrome: Tissue Doppler Echocardiographic Investigation

    Directory of Open Access Journals (Sweden)

    Selma YAZICI

    2010-05-01

    Full Text Available Aim: We aim to investigate besides the cardiac structures and functions by both conventionalmethods and Tissue Doppler Echocardiography (TDE which is a new and useful method inpatients with Fibromyalgia (FM. Additionally, we evaluated QT parameters (QT maximum,QT minimum and QT dispertion with the use of electrocardiography in order to measure theautonomic dysfunction which is a possible mechanism in the pathogenesis of the disease. Methods: The study was performed on 42 patients (mean age 41 years, 38 female and 38completely healthy subjects (35 female, mean age of 42 years who were admitted to the sameclinic were collected as the control group. All the individuals were undergone a completephysical examination, electrocardiography (recordings were displayed at 50 mm/s speed andechocardiography evaluation (both conventional methods and TDE.Results: Analysis of electrocardiographic recordings revealed mildly increased mean QTdispertion in the patient group, but this difference was statistically insignificant. Analysis ofconventional echocardiographic parameters revealed similar results between the patient groupand the control cases. However, an important finding of this study is that significant diastolicdysfunction was found in the patient group which was recorded with the TDE technique. Emwave velocity and Em/Am ratios were significantly lower in patients with FM compared withcontrols (p<0.005, p<0.01, respectively. Sm and Am waves velocities were similar in bothgroups. Conclusion: In this study, significant left ventricular diastolic dysfunction which was detectedby TDE technique can partly explain several symptoms such as fatigue and dyspnea in FM. Inaddition, fully cardiac evaluation of patients with FM might be obtained supporting findingsthe autonomic dysfunction theory in fibromyalgia pathogenesis.

  4. A fiber optic Doppler sensor and its application in debonding detection for composite structures.

    Science.gov (United States)

    Li, Fucai; Murayama, Hideaki; Kageyama, Kazuro; Meng, Guang; Ohsawa, Isamu; Shirai, Takehiro

    2010-01-01

    Debonding is one of the most important damage forms in fiber-reinforced composite structures. This work was devoted to the debonding damage detection of lap splice joints in carbon fiber reinforced plastic (CFRP) structures, which is based on guided ultrasonic wave signals captured by using fiber optic Doppler (FOD) sensor with spiral shape. Interferometers based on two types of laser sources, namely the He-Ne laser and the infrared semiconductor laser, are proposed and compared in this study for the purpose of measuring Doppler frequency shift of the FOD sensor. Locations of the FOD sensors are optimized based on mechanical characteristics of lap splice joint. The FOD sensors are subsequently used to detect the guided ultrasonic waves propagating in the CFRP structures. By taking advantage of signal processing approaches, features of the guided wave signals can be revealed. The results demonstrate that debonding in the lap splice joint results in arrival time delay of the first package in the guided wave signals, which can be the characteristic for debonding damage inspection and damage extent estimation.

  5. What every radiologist should know about paediatric echocardiography

    International Nuclear Information System (INIS)

    Sorantin, Erich; Heinzl, Bernd

    2014-01-01

    Congenital heart defects (CHD) occur in less than one percent of all newborns. Echocardiography represents the imaging modality of choice for morphological and functional assessment. In childhood the different CHD types can be diagnosed trustfully and can be performed bedside. In the follow-up of CHD cross sectional imaging plays an important role and therefore it is essential for the radiologist to know the features, challenges and limitations of echocardiography. Within this review article a systematic approach for morphological and functional assessment of the heart will is given along with representative example images. In addition, typical echocardiographic findings in common CHD is presented. In older children, adolescents and grown-ups with CHD (GUCH) echocardiography suffers from limitations – partially due to skeletal deformations and lung emphysema. In particular right ventricular function assessment is not always possible by echocardiography. Therefore strengths and limitations of echocardiography will be discussed the role of cardiac magnetic resonance imaging (cMRI) and cardiac computed tomography (cCT) emphasized

  6. What every radiologist should know about paediatric echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Sorantin, Erich, E-mail: erich.sorantin@medunigraz.at [Division of Pediatric Radiology, Department of Radiology, Medical University Graz, Auenbruggerplatz 34, A-8036 Graz (Austria); Heinzl, Bernd [Division of Pediatric Cardiology, Department of Pediatric and Adolescent Medicine, Medical University Graz, Auenbruggerplatz 34, A-8036 Graz (Austria)

    2014-09-15

    Congenital heart defects (CHD) occur in less than one percent of all newborns. Echocardiography represents the imaging modality of choice for morphological and functional assessment. In childhood the different CHD types can be diagnosed trustfully and can be performed bedside. In the follow-up of CHD cross sectional imaging plays an important role and therefore it is essential for the radiologist to know the features, challenges and limitations of echocardiography. Within this review article a systematic approach for morphological and functional assessment of the heart will is given along with representative example images. In addition, typical echocardiographic findings in common CHD is presented. In older children, adolescents and grown-ups with CHD (GUCH) echocardiography suffers from limitations – partially due to skeletal deformations and lung emphysema. In particular right ventricular function assessment is not always possible by echocardiography. Therefore strengths and limitations of echocardiography will be discussed the role of cardiac magnetic resonance imaging (cMRI) and cardiac computed tomography (cCT) emphasized.

  7. 3D atom microscopy in the presence of Doppler shift

    Science.gov (United States)

    Rahmatullah; Chuang, You-Lin; Lee, Ray-Kuang; Qamar, Sajid

    2018-03-01

    The interaction of hot atoms with laser fields produces a Doppler shift, which can severely affect the precise spatial measurement of an atom. We suggest an experimentally realizable scheme to address this issue in the three-dimensional position measurement of a single atom in vapors of rubidium atoms. A three-level Λ-type atom-field configuration is considered where a moving atom interacts with three orthogonal standing-wave laser fields and spatial information of the atom in 3D space is obtained via an upper-level population using a weak probe laser field. The atom moves with velocity v along the probe laser field, and due to the Doppler broadening the precision of the spatial information deteriorates significantly. It is found that via a microwave field, precision in the position measurement of a single hot rubidium atom can be attained, overcoming the limitation posed by the Doppler shift.

  8. Quantum Interference between Autonomous Single-Photon Sources from Doppler-Broadened Atomic Ensemble

    OpenAIRE

    Jeong, Teak; Lee, Yoon-Seok; Park, Jiho; Kim, Heonoh; Moon, Han Seb

    2017-01-01

    To realize a quantum network based on quantum entanglement swapping, bright and completely autonomous sources are essentially required. Here, we experimentally demonstrate Hong-Ou-Mandel (HOM) quantum interference between two independent bright photon pairs generated via the spontaneous four-wave mixing in Doppler-broadened ladder-type 87Rb atoms. Bright autonomous heralded single photons are operated in a continuous-wave (CW) mode with no synchronization or supplemental filters. The four-fol...

  9. Evaluating the cardiac function of duchenne muscular dystrophy with Doppler Tei index

    International Nuclear Information System (INIS)

    Yao Fengjuan; Zheng Ju; Lu Kun; Liu Donghong; Wu Miaoling; Lin Hong; Zhang Cheng; Yu Hongkui

    2007-01-01

    Objective: To evaluate the cardiac function of early Duchenne muscular dystrophy (DMD) by left ventricular ejection fraction (LVEF) and pulse Doppler Tei index. Methods: Twenty-eight DMD patients and fifteen normal people were studied. LVEF, E/A and Tei index were measured and calculated by M-mode and Pulse wave Doppler respectively. Results: Compared with control group, Tei index and IRT were significantly high, and there were not significant difference in LVEF(%) and E/A. Conclusion: Tei index was valuable in assessing cardiac function of early DMD. (authors)

  10. Effect of well-controlled gestational diabetes on left ventricular diastolic dysfunction in neonates.

    Science.gov (United States)

    Ghandi, Yazdan; Habibi, Danial; Nasri, Khadijeh; Alinejad, Saeed; Taherahmad, Hassan; Arjmand Shabestari, Ali; Nematinejad, Ali

    2018-06-17

    There are some evidences supporting the relation between gestational diabetes mellitus (GDM) and diastolic dysfunction. The aim of our study was to investigate the effect of well-controlled GDM on morphological and functional myocardium. We designed a prospective cross-sectional study to evaluate left ventricular (LV) diastolic function of 60 neonates born from mothers with well-controlled GDM (case group) on days of 3-5 after birth. The infants of diabetic mothers (IDM) group were divided into two groups: diabetic mothers treated only with diet (class A) and group of mothers on medical therapy by insulin or metformin (class B). Traditional echocardiography and pulsed-wave Doppler (PWD), tissue Doppler imaging (TDI) were performed for all the neonates. The study group consisted of 60 neonates as males (M) = 32, (0.53%) and females (F) = 28, (0.46%). Using M-mode echocardiography, interventricular septum thickness (IVS), and LV mass were significantly higher in IDM than control group (p = .0001). The PWD showed both a significantly more peak mitral flow at early diastolic wave (E) and an early filling deceleration time (E-DT) (p = .0001). Tissue Doppler echocardiography parameters A' (cm/s) (p = .0001), E' (cm/s) (p = .002), and E'/A' ratio (p = .0001), left ventricular myocardial performance index (LVMPI), and isovolumetric relaxation time (IVRT) were outstandingly different between the two groups (p = .0001, respectively). Evaluating the GDM group mothers of class A and class B, no significant difference was noted in PWD or TDI parameters compared with the healthy ones. It seems that neonates of mothers with well-controlled GDM are still at increased risk of cardiac hypertrophy, subclinical diastolic dysfunction, and impaired left ventricular relaxation. This can be interpreted that focusing only on glycemic control is not enough to prevent cardiac dysfunction.

  11. Echocardiography and cardiac resynchronisation therapy, friends or foes?

    Science.gov (United States)

    van Everdingen, W M; Schipper, J C; van 't Sant, J; Ramdat Misier, K; Meine, M; Cramer, M J

    2016-01-01

    Echocardiography is used in cardiac resynchronisation therapy (CRT) to assess cardiac function, and in particular left ventricular (LV) volumetric status, and prediction of response. Despite its widespread applicability, LV volumes determined by echocardiography have inherent measurement errors, interobserver and intraobserver variability, and discrepancies with the gold standard magnetic resonance imaging. Echocardiographic predictors of CRT response are based on mechanical dyssynchrony. However, parameters are mainly tested in single-centre studies or lack feasibility. Speckle tracking echocardiography can guide LV lead placement, improving volumetric response and clinical outcome by guiding lead positioning towards the latest contracting segment. Results on optimisation of CRT device settings using echocardiographic indices have so far been rather disappointing, as results suffer from noise. Defining response by echocardiography seems valid, although re-assessment after 6 months is advisable, as patients can show both continuous improvement as well as deterioration after the initial response. Three-dimensional echocardiography is interesting for future implications, as it can determine volume, dyssynchrony and viability in a single recording, although image quality needs to be adequate. Deformation patterns from the septum and the derived parameters are promising, although validation in a multicentre trial is required. We conclude that echocardiography has a pivotal role in CRT, although clinicians should know its shortcomings.

  12. Diagnostic value of echocardiography in infective endocarditis

    International Nuclear Information System (INIS)

    Luo Yinli; Ni Xianda; Hu Yuanping; Liu Jingyun; Yang Weiyu

    2010-01-01

    Objective: To investigate the feature and value of echocardiography for diagnosing infective endocarditis. Methods: The shape, size, echogenicity, distribution of vegetations and valvular injury of the heart were observed in 30 patients with infective endocarditis. Results: The vegetations were located in the aortic valves (10 cases), bicuspid valves (5), tricuspid valve (1), pulmonary valve (2), main pulmonary artery with patent ductus arteriosus (2), and right ventricle with ventricular septal defect (2). The size of vegetation ranged from 2 to 27 mm and the echogenicity of vegetations was low to high. The location, size, shape and amount of vegetations observed on echocardiography correlated well with the operative findings. Echocardiography also demonstrated underlying heart disease and abnormal hemodynamics induced by infective endocarditis. Conclusion: Echocardiography can determine the location, size, shape, amount of vegetation and concomitant cardiac disease in patients with infective endocarditis. It play an important role in treatment and prognosis. (authors)

  13. Echocardiography as an indication of continuous-time cardiac quiescence

    Science.gov (United States)

    Wick, C. A.; Auffermann, W. F.; Shah, A. J.; Inan, O. T.; Bhatti, P. T.; Tridandapani, S.

    2016-07-01

    Cardiac computed tomography (CT) angiography using prospective gating requires that data be acquired during intervals of minimal cardiac motion to obtain diagnostic images of the coronary vessels free of motion artifacts. This work is intended to assess B-mode echocardiography as a continuous-time indication of these quiescent periods to determine if echocardiography can be used as a cost-efficient, non-ionizing modality to develop new prospective gating techniques for cardiac CT. These new prospective gating approaches will not be based on echocardiography itself but on CT-compatible modalities derived from the mechanics of the heart (e.g. seismocardiography and impedance cardiography), unlike the current standard electrocardiogram. To this end, echocardiography and retrospectively-gated CT data were obtained from ten patients with varied cardiac conditions. CT reconstructions were made throughout the cardiac cycle. Motion of the interventricular septum (IVS) was calculated from both echocardiography and CT reconstructions using correlation-based, deviation techniques. The IVS was chosen because it (1) is visible in echocardiography images, whereas the coronary vessels generally are not, and (2) has been shown to be a suitable indicator of cardiac quiescence. Quiescent phases were calculated as the minima of IVS motion and CT volumes were reconstructed for these phases. The diagnostic quality of the CT reconstructions from phases calculated from echocardiography and CT data was graded on a four-point Likert scale by a board-certified radiologist fellowship-trained in cardiothoracic radiology. Using a Wilcoxon signed-rank test, no significant difference in the diagnostic quality of the coronary vessels was found between CT volumes reconstructed from echocardiography- and CT-selected phases. Additionally, there was a correlation of 0.956 between the echocardiography- and CT-selected phases. This initial work suggests that B-mode echocardiography can be used as a

  14. Radar observations of ion cyclotron waves associated with two barium shaped-charge releases

    International Nuclear Information System (INIS)

    Providakes, J.; Swartz, W.E.; Kelley, M.C.; Djuth, F.T.; Noble, S.; Jost, R.J.

    1990-01-01

    A 50-MHz Doppler radar interferometer and a 138-MHz Doppler radar were operated from Kennedy Space Center to study 3-m and 1-m plasma waves associated with two shaped-charged barium releases from Wallops Island, Virginia, on May 13, 1986. During the first release, interferometer and Doppler power spectral studies showed the existence of short-lived ( + EIC waves were unstable for field-aligned electron drifts greater than 0.7υ the at the altitude of 510 km in a multispecies (O + , NO + , or similarly O 2 + ) ionospheric plasma. The authors interpret the 30-Hz waves seen by the two radars far above the release as strong electrostatic ion cyclotron waves generated by intense field-aligned currents associated with the barium stream acting like an MHD generator coupled to the ionospheres

  15. A Doppler Radar System for Sensing Physiological Parameters in Walking and Standing Positions

    Directory of Open Access Journals (Sweden)

    Malikeh Pour Ebrahim

    2017-03-01

    Full Text Available Doppler radar can be implemented for sensing physiological parameters wirelessly at a distance. Detecting respiration rate, an important human body parameter, is essential in a range of applications like emergency and military healthcare environments, and Doppler radar records actual chest motion. One challenge in using Doppler radar is being able to monitor several patients simultaneously and in different situations like standing, walking, or lying. This paper presents a complete transmitter-receiver Doppler radar system, which uses a 4 GHz continuous wave radar signal transmission and receiving system, to extract base-band data from a phase-shifted signal. This work reports experimental evaluations of the system for one and two subjects in various standing and walking positions. It provides a detailed signal analysis of various breathing rates of these two subjects simultaneously. These results will be useful in future medical monitoring applications.

  16. Explaining Polarization Reversals in STEREO Wave Data

    Science.gov (United States)

    Breneman, A.; Cattell, C.; Wygant, J.; Kersten, K.; Wilson, L, B., III; Dai, L.; Colpitts, C.; Kellogg, P. J.; Goetz, K.; Paradise, A.

    2012-01-01

    Recently Breneman et al. reported observations of large amplitude lightning and transmitter whistler mode waves from two STEREO passes through the inner radiation belt (Lpaper. We show, with a combination of observations and simulated wave superposition, that these polarization reversals are due to the beating of an incident electromagnetic whistler mode wave at 21.4 kHz and linearly polarized, symmetric lower hybrid sidebands Doppler-shifted from the incident wave by +/-200 Hz. The existence of the lower hybrid waves is consistent with the parametric decay mechanism of Lee and Kuo whereby an incident whistler mode wave decays into symmetric, short wavelength lower hybrid waves and a purely growing (zero-frequency) mode. Like the lower hybrid waves, the purely growing mode is Doppler-shifted by 200 Hz as observed on STEREO. This decay mechanism in the upper ionosphere has been previously reported at equatorial latitudes and is thought to have a direct connection with explosive spread F enhancements. As such it may represent another dissipation mechanism of VLF wave energy in the ionosphere and may help to explain a deficit of observed lightning and transmitter energy in the inner radiation belts as reported by Starks et al.

  17. Clinical Stress Echocardiography

    NARCIS (Netherlands)

    S.E. Karagiannis

    2007-01-01

    textabstractTwo-dimensional echocardiography is a commonly used non-invasive method for the assessment of left ventricular function. It provides precise information on both global and segmental myocardial function by displaying endocardial motion and wall thickening. Dobutamine stress

  18. Hand-carried ultrasound performed at bedside in cardiology inpatient setting – a comparative study with comprehensive echocardiography

    Directory of Open Access Journals (Sweden)

    Ramires Jose F

    2004-11-01

    Full Text Available Abstract Background Hand-carried ultrasound (HCU devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evaluation using HCU and comprehensive echocardiography (CE, in cardiology inpatient setting. Methods We studied 44 consecutive patients (mean age 54 ± 18 years, 25 men who underwent bedside echocardiography using HCU and CE. HCU was performed by a cardiologist with level-2 training in the performance and interpretation of echocardiography, using two-dimensional imaging, color Doppler, and simple calliper measurements. CE was performed by an experienced echocardiographer (level-3 training and considered as the gold standard. Results There were no significant differences in cardiac chamber dimensions and left ventricular ejection fraction determined by the two techniques. The agreement between HCU and CE for the detection of segmental wall motion abnormalities was 83% (Kappa = 0.58. There was good agreement for detecting significant mitral valve regurgitation (Kappa = 0.85, aortic regurgitation (kappa = 0.89, and tricuspid regurgitation (Kappa = 0.74. A complete evaluation of patients with stenotic and prosthetic dysfunctional valves, as well as pulmonary hypertension, was not possible using HCU due to its technical limitations in determining hemodynamic parameters. Conclusion Bedside evaluation using HCU is helpful for assessing cardiac chamber dimensions, left ventricular global and segmental function, and significant valvular regurgitation. However, it has limitations regarding hemodynamic assessment, an important issue in the cardiology inpatient setting.

  19. Screening of Chronic Obstructive Pulmonary Disease Patients for Pulmonary Arterial Hypertension Using Two-Dimensional Transthoracic Doppler Echocardiography in Tertiary Care Hospital in India

    Directory of Open Access Journals (Sweden)

    Vinay Mahishale

    2015-01-01

    Full Text Available Background: Chronic obstructive pulmonary disease (COPD and pulmonary arterial hypertension (PAH are common and underdiagnosed medical conditions in India. Prevalence of these chronic diseases is high both in rural and urban areas. However, the exact prevalence of PAH in Indian COPD patients is unclear. Comorbid conditions like PAH have a great impact on the outcome of COPD in the form of severity, exacerbations, morbidity, and mortality. Right heart catheterization remains the gold standard test for diagnosis of PAH, but it is invasive and practically not feasible. Aims and objectives: The present study objective was to screen COPD patients for PAH using two-dimensional transthoracic Doppler echocardiography (ECHO in Tertiary Care Hospital. Results: A total of 2040 patients with a confirmed diagnosis of COPD were enrolled in the study. Among these patients, 1509 were males (73.9%, 531 were females (23.06%, and 1428 were known or ex-smokers (70%. None of the females were smokers, but there was a history of biomass fuel exposure for >10 years. As per global initiative for chronic obstructive lung disease criteria, mild, moderate, severe, and very severe COPD was noted in 525,629,511, and 375 patients, respectively. When they were screened using ECHO, prevalence of PAH was 41.96% as 856 subjects had PAH. Prevalence of PAH among mild, moderate, severe, and very severe COPD was 23.8%, 34.81%, 48.53%, and 70.4%, respectively. There was a linear relationship between PAH and severity of COPD. Conclusion: PAH is very common in COPD patients in India. As the severity of COPD increased, the frequency and degree of PAH also increased. ECHO is an excellent tool for detection of PAH in COPD patients. All patients with severe to very severe COPD should be routinely screened by ECHO for PAH and with mild to moderate COPD, who have dyspnea out of proportion to their clinical condition should also be screened for PAH.

  20. Doppler Tomography

    Science.gov (United States)

    Marsh, T. R.

    I review the method of Doppler tomography which translates binary-star line profiles taken at a series of orbital phases into a distribution of emission over the binary. I begin with a discussion of the basic principles behind Doppler tomography, including a comparison of the relative merits of maximum entropy regularisation versus filtered back-projection for implementing the inversion. Following this I discuss the issue of noise in Doppler images and possible methods for coping with it. Then I move on to look at the results of Doppler Tomography applied to cataclysmic variable stars. Outstanding successes to date are the discovery of two-arm spiral shocks in cataclysmic variable accretion discs and the probing of the stream/magnetospheric interaction in magnetic cataclysmic variable stars. Doppler tomography has also told us much about the stream/disc interaction in non-magnetic systems and the irradiation of the secondary star in all systems. The latter indirectly reveals such effects as shadowing by the accretion disc or stream. I discuss all of these and finish with some musings on possible future directions for the method. At the end I include a tabulation of Doppler maps published in refereed journals.

  1. MODERN POSSIBILITIES OF SPECKLE TRACKING ECHOCARDIOGRAPHY IN CLINICAL PRACTICE

    Directory of Open Access Journals (Sweden)

    V. S. Nikiforov

    2017-01-01

    Full Text Available Speckle-tracking echocardiography is promising modern technique for evaluation of structural and functional changes in the myocardium. It evaluates the indicator of global longitudinal myocardial deformation, which is more sensitive than ejection fraction to early changes of left ventricular contractility. The diagnostic capabilities of speckle tracking echocardiography are reflected in clinical recommendations and consensus statements of European Society of Cardiology (ESC, European Association of Cardiovascular Imaging (EACVI and American Society of Echocardiography (ASE. The aim of this paper is describe basic principles of speckle tracking echocardiography and clinical applications of this new technology. Attention is paid to the use of speckle tracking echocardiography in such heart pathologies as heart failure, coronary heart disease and myocardial infarction, left ventricular hypertrophy in arterial hypertension, hypertrophic cardiomyopathy and amyloidosis of the heart, valvular heart disease, constrictive pericarditis and cancer therapy-induced cardiotoxicity.

  2. Four-dimensional echocardiography area strain combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis.

    Science.gov (United States)

    Deng, Yan; Peng, Long; Liu, Yuan-Yuan; Yin, Li-Xue; Li, Chun-Mei; Wang, Yi; Rao, Li

    2017-09-01

    The aim of this prospective study was to assess the diagnosis value of four-dimensional echocardiography area strain (AS) combined with exercise stress echocardiography to evaluate left ventricular regional systolic function in patients with mild single vessel coronary artery stenosis. Based on treadmill exercise load status, two-dimensional conventional echocardiography and four-dimensional echocardiography area strain were performed on patients suspected coronary artery disease before coronary angiogram. Thirty patients (case group) with mild left anterior descending coronary artery stenosis (stenosis Four-dimensional echocardiography area strain combined with exercise stress echocardiography could sensitively find left ventricular regional systolic function abnormality in patients with mild single vessel coronary artery stenosis, and locate stenosis coronary artery accordingly. © 2017, Wiley Periodicals, Inc.

  3. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2014-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  4. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2015-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/ critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  5. The use of echocardiography in acute cardiovascular care

    DEFF Research Database (Denmark)

    Lancellotti, Patrizio; Price, Susanna; Edvardsen, Thor

    2015-01-01

    Echocardiography is one of the most powerful diagnostic and monitoring tools available to the modern emergency/critical care practitioner. Currently, there is a lack of specific European Association of Cardiovascular Imaging/Acute Cardiovascular Care Association recommendations for the use...... of echocardiography in acute cardiovascular care. In this document, we describe the practical applications of echocardiography in patients with acute cardiac conditions, in particular with acute chest pain, acute heart failure, suspected cardiac tamponade, complications of myocardial infarction, acute valvular heart...

  6. Comparison of Hyperemic Impedance Echocardiography with Dobutamine Stress Echocardiography to Detect Inducible Myocardial Ischemia: A Pilot Study.

    Science.gov (United States)

    Patel, Jijibhoy J; Gupta, Ankur; Nanda, Navin C

    2016-03-01

    Stress echocardiography using exercise or pharmacological stressors is either contraindicated or associated with significant side effects in some patients. This pilot study was designed to evaluate a new technique, hyperemic impedance echocardiography (HIE). It is based on reactive coronary hyperemia when transient limb ischemia is induced by tourniquet inflation. We hypothesized that this physiologic coronary hyperemia can identify inducible myocardial ischemia by assessment of regional wall motion abnormalities on echocardiography when compared with dobutamine stress echocardiography (DSE). Twenty consecutive outpatients with suspected stable coronary artery disease (CAD) who underwent clinically indicated DSE were recruited for performance of HIE after informed consent was obtained. Standard graded dobutamine infusion protocol from 5 to 40 μg/kg per min was used for DSE. HIE was performed by inflating tourniquets at a pressure of 10 mmHg below the systolic blood pressure for 1 minute in three of four extremities at a time for total of four cycles. Echocardiography was performed immediately after the last rotating tourniquet deflation. DSE and HIE were classified as abnormal for development of new or worsening wall motion abnormality in at least one myocardial segment. Test characteristics were also determined for a subset of these patients (n = 12) who underwent clinically indicated coronary angiography. Hyperemic impedance echocardiography showed 86% sensitivity, 67% specificity, 86% positive predictive value, and 67% negative predictive value with a test accuracy of 80% to detect inducible myocardial wall motion abnormalities when compared with DSE. HIE also showed 83% sensitivity, 75% negative predictive value with a test accuracy of 66.7% for detection of significant (≥50% diameter stenosis) CAD on coronary angiography. In this pilot study, HIE was a feasible, safe, and promising method for detection of inducible myocardial ischemia by assessment of

  7. Doppler velocity measurements from large and small arteries of mice

    Science.gov (United States)

    Reddy, Anilkumar K.; Madala, Sridhar; Entman, Mark L.; Michael, Lloyd H.; Taffet, George E.

    2011-01-01

    With the growth of genetic engineering, mice have become increasingly common as models of human diseases, and this has stimulated the development of techniques to assess the murine cardiovascular system. Our group has developed nonimaging and dedicated Doppler techniques for measuring blood velocity in the large and small peripheral arteries of anesthetized mice. We translated technology originally designed for human vessels for use in smaller mouse vessels at higher heart rates by using higher ultrasonic frequencies, smaller transducers, and higher-speed signal processing. With these methods one can measure cardiac filling and ejection velocities, velocity pulse arrival times for determining pulse wave velocity, peripheral blood velocity and vessel wall motion waveforms, jet velocities for the calculation of the pressure drop across stenoses, and left main coronary velocity for the estimation of coronary flow reserve. These noninvasive methods are convenient and easy to apply, but care must be taken in interpreting measurements due to Doppler sample volume size and angle of incidence. Doppler methods have been used to characterize and evaluate numerous cardiovascular phenotypes in mice and have been particularly useful in evaluating the cardiac and vascular remodeling that occur following transverse aortic constriction. Although duplex ultrasonic echo-Doppler instruments are being applied to mice, dedicated Doppler systems are more suitable for some applications. The magnitudes and waveforms of blood velocities from both cardiac and peripheral sites are similar in mice and humans, such that much of what is learned using Doppler technology in mice may be translated back to humans. PMID:21572013

  8. Electromagnetic Cyclotron Waves in the Solar Wind: Wind Observation and Wave Dispersion Analysis

    Science.gov (United States)

    Jian, L. K.; Moya, P. S.; Vinas, A. F.; Stevens, M.

    2016-01-01

    Wind observed long-lasting electromagnetic cyclotron waves near the proton cyclotron frequency on 11 March 2005, in the descending part of a fast wind stream. Bi-Maxwellian velocity distributions are fitted for core protons, beam protons, and alpha-particles. Using the fitted plasma parameters we conduct kinetic linear dispersion analysis and find ion cyclotron and/or firehose instabilities grow in six of 10 wave intervals. After Doppler shift, some of the waves have frequency and polarization consistent with observation, thus may be correspondence to the cyclotron waves observed.

  9. Quantification in echocardiography

    NARCIS (Netherlands)

    Korsten, H.H.M.; Mischi, M.; Grouls, R.J.E.; Jansen, A.H.M.; Dantzig, van J.M.; Peels, C.H.

    2006-01-01

    Until recently, more than 2200 Swan Ganz catheters were used annually in the operating rooms (OR) and intensive care unit (ICU) of the Catharina Hospital in Eindhoven, The Netherlands. After cardiologists who were specialists in echocardiography (ECHO) trained anesthesiologists in ECHO, the need for

  10. Systematic review of cardiac output measurements by echocardiography vs. thermodilution

    DEFF Research Database (Denmark)

    Wetterslev, Mik; Møller-Sørensen, Hasse; Johansen, Rasmus Rothmann

    2016-01-01

    PURPOSE: Echocardiography is frequently used in the hemodynamic evaluation of critically ill patients, but inaccurate measurements may lead to wrong clinical decisions. The aim of our systematic review was to investigate the interchangeability of echocardiography with thermodilution technique...... of the studies assessed left-sided heart structures and the majority had small bias, wide limits of agreement, and high percentage error between echocardiography and thermodilution. In only two of the 24 studies the precision of each technique (echocardiography and thermodilution) was assessed before comparing...... them. In the single study evaluating trending ability using valid methodology, agreement was observed between echocardiography and thermodilution in detecting the directional changes in cardiac output, but the magnitude of changes varied considerably. CONCLUSIONS: The majority of studies comparing...

  11. Influence of immune-mediated hemolytic anemia on flow velocities in the portal vein and caudal vena cava measured by use of pulsed-wave Doppler ultrasonography in dogs.

    Science.gov (United States)

    Smith, Rachel Policelli; Koenigshof, Amy M; Smith, Daniel J; Strom, Phillip R; Nelson, Nathan C

    2018-05-01

    OBJECTIVE To compare blood flow velocities of the portal vein (PV) and caudal vena cava (CVC) measured by use of pulsed-wave Doppler ultrasonography in clinically normal dogs and dogs with primary immune-mediated hemolytic anemia (IMHA). ANIMALS 11 client-owned dogs admitted to a veterinary teaching hospital for management of primary IMHA and 21 staff- or student-owned clinically normal dogs. PROCEDURES Flow velocities in the PV and CVC at the porta hepatis were evaluated in conscious unsedated dogs with concurrent ECG monitoring; evaluations were performed before dogs with IMHA received heparin or blood transfusions. Three measurements of peak velocity at end expiration were obtained for each vessel, and the mean was calculated. Results were compared between IMHA and control groups. RESULTS Mean ± SD blood flow velocity in the CVC differed between control (63.0 ± 18.6 cm/s) and IMHA (104 ± 36.9 cm/s) groups. Variance in dogs with IMHA was significantly greater than that for the clinically normal dogs. No significant difference in blood flow velocity in the PV was detected between IMHA and control dogs. CONCLUSIONS AND CLINICAL RELEVANCE Higher blood flow velocities were detected by use of pulsed-wave Doppler ultrasonography in the CVC of dogs with naturally occurring IMHA and may be used to predict anemia in patients suspected of having IMHA.

  12. Transthoracic contrast echocardiography using vitamin B6 and sodium bicarbonate as contrast agents for the diagnosis of patent foramen ovale.

    Science.gov (United States)

    He, Jiang-Chun; Zheng, Jian-Yong; Li, Xin; Yang, Ye; Zhang, Bo-Yang; Chen, Yu; Li, Xian-Feng; Liu, Ying-Ming; Cao, Yi; Zhao, Li; Li, Tian-Chang

    2017-08-01

    To evaluate the utility of transthoracic contrast echocardiography (cTTE) using vitamin B6 and sodium bicarbonate as contrast agents for diagnosing right-to-left shunt (RLS) caused by patent foramen ovale (PFO) compared to that of transesophageal echocardiography (TEE). We investigated 125 patients admitted to our neurology department with unexplained cerebral infarction and migraine. All patients underwent cTTE using vitamin B6 and sodium bicarbonate as contrast agents, after which they underwent transthoracic echocardiography. The Doppler signal was recorded during the Valsalva maneuver, and TEE examinations were performed. The feasibility, diagnostic sensitivity, and safety of cTTE and TEE for PFO recognition were compared. Evidence of PFO was found in 49 (39.20%) patients with cTTE, more than were detected with TEE (39, 31.20%) (χ 2 =5.0625, P=0.0244). cTTE had a sensitivity of 92.31% and a specificity of 84.88% for diagnosing PFO, showing high concordance with TEE for PFO recognition (κ=0.72). Further, results of a semi-quantitative evaluation of PFO-RLS by cTTE were better than those with TEE (Z=-2.011, P=0.044). No significant adverse reaction was discovered during cTTE examination. cTTE using vitamin B6 and sodium bicarbonate as contrast agents has relatively good sensitivity and specificity for diagnosing RLS caused by PFO when compared with those for TEE. Using vitamin B6 and sodium bicarbonate as contrast agents to perform cTTE is recommended for detecting and diagnosing the PFO due to its simplicity, non-invasive character, low cost, and high feasibility.

  13. Endosonographic and color doppler flow imaging alterations observed within irradiated rectal cancer

    International Nuclear Information System (INIS)

    Alexander, Archie A.; Palazzo, Juan P.; Ahmad, Neelofur R.; Liu, J.-B.; Forsberg, Flemming; Marks, John

    1996-01-01

    Purpose: To correlate the endosonographic and color Doppler flow imaging alterations observed in irradiated rectal cancers with the pathologic features of radiation response, and to evaluate the potential impact of altered blood flow on the integrity of the surgical anastamosis. Methods and Materials: Endosonography with color and pulsed wave Doppler was performed on 20 rectal cancer masses before and after high dose preoperative radiation (XRT). Pre- and post-XRT observations included comparing alterations in tumor size, sonographic echotexture, color Doppler flow, and pulsatility indices. Comparisons were made with pathologic findings in the irradiated specimens and with the incidence of anastomotic failure. Results: Compared to pre-XRT observations, irradiated rectal cancers decreased in size and became either mixed in echogenicity with less apparent color Doppler flow (16 of 20) or unchanged in color Doppler flow and echotexture (4 of 20). Those with less flow (16 of 20) were imaged later (mean = 90.2 ± 12.1 days) than those without change in color Doppler flow (mean = 21.7 ± 2.7 days). Pathologically, the group of four without change in color Doppler signal had features of acute inflammation which were not observed in 16 of 20 imaged later. Based on pulsatility index measurements, both high and low resistance vessels were detected and confirmed by immunohistochemical staining, and features of postradiation obliterative vasculitis were observed. Only one primary anastomosis in 14 patients with decreased flow failed. Conclusions: The sonographic and color Doppler flow imaging alterations observed within irradiated rectal cancer correlated with changes of postradiation obliterative vasculitis. The apparent diminished local blood flow within high and low resistance vessels post-XRT did not result in an increased incidence of anastomotic failures

  14. Minimally destructive, Doppler measurement of a quantized flow in a ring-shaped Bose-Einstein condensate

    Science.gov (United States)

    Kumar, A.; Anderson, N.; Phillips, W. D.; Eckel, S.; Campbell, G. K.; Stringari, S.

    2016-02-01

    The Doppler effect, the shift in the frequency of sound due to motion, is present in both classical gases and quantum superfluids. Here, we perform an in situ, minimally destructive measurement, of the persistent current in a ring-shaped, superfluid Bose-Einstein condensate using the Doppler effect. Phonon modes generated in this condensate have their frequencies Doppler shifted by a persistent current. This frequency shift will cause a standing-wave phonon mode to be ‘dragged’ along with the persistent current. By measuring this precession, one can extract the background flow velocity. This technique will find utility in experiments where the winding number is important, such as in emerging ‘atomtronic’ devices.

  15. Teaching focused echocardiography for rheumatic heart disease screening

    Directory of Open Access Journals (Sweden)

    Daniel Engelman

    2015-01-01

    Full Text Available Screening for rheumatic heart disease (RHD requires workers skilled in echocardiography, which typically involves prolonged, specialized training. Task shifting echocardiographic screening to nonexpert health workers may be a solution in settings with limited human resources. An 8-week training program was designed to train health workers without any prior experience in focused echocardiography for RHD screening. Seven health workers participated. At the completion of training, the health workers performed unsupervised echocardiography on 16 volunteer children with known RHD status. A pediatric cardiologist assessed image quality. Participants provided qualitative feedback. The quality of echocardiograms were high at completion of training (55 of 56 were adequate for diagnosis and all cases of RHD were identified. Feedback was strongly positive. Training health workers to perform focused echocardiography for RHD screening is feasible. After systematic testing for accuracy, this training program could be adapted in other settings seeking to expand echocardiographic capabilities.

  16. Teaching focused echocardiography for rheumatic heart disease screening

    International Nuclear Information System (INIS)

    Engelman, Daniel; Kado, Joseph H; Reményi, Bo; Colquhoun, Samantha M; Watson, Caroline; Rayasidamu, Sera C; Steer, Andrew C

    2005-01-01

    Screening for rheumatic heart disease (RHD) requires workers skilled in echocardiography, which typically involves prolonged, specialized training. Task shifting echocardiographic screening to nonexpert health workers may be a solution in settings with limited human resources. An 8-week training program was designed to train health workers without any prior experience in focused echocardiography for RHD screening. Seven health workers participated. At the completion of training, the health workers performed unsupervised echocardiography on 16 volunteer children with known RHD status. A pediatric cardiologist assessed image quality. Participants provided qualitative feedback. The quality of echocardiograms were high at completion of training (55 of 56 were adequate for diagnosis) and all cases of RHD were identified. Feedback was strongly positive. Training health workers to perform focused echocardiography for RHD screening is feasible. After systematic testing for accuracy, this training program could be adapted in other settings seeking to expand echocardiographic capabilities

  17. Association Between Echocardiography Laboratory Accreditation and the Quality of Imaging and Reporting for Valvular Heart Disease.

    Science.gov (United States)

    Thaden, Jeremy J; Tsang, Michael Y; Ayoub, Chadi; Padang, Ratnasari; Nkomo, Vuyisile T; Tucker, Stephen F; Cassidy, Cynthia S; Bremer, Merri; Kane, Garvan C; Pellikka, Patricia A

    2017-08-01

    It is presumed that echocardiographic laboratory accreditation leads to improved quality, but there are few data. We sought to compare the quality of echocardiographic examinations performed at accredited versus nonaccredited laboratories for the evaluation of valvular heart disease. We enrolled 335 consecutive valvular heart disease subjects who underwent echocardiography at our institution and an external accredited or nonaccredited institution within 6 months. Completeness and quality of echocardiographic reports and images were assessed by investigators blinded to the external laboratory accreditation status and echocardiographic results. Compared with nonaccredited laboratories, accredited sites more frequently reported patient sex (94% versus 78%; P heart disease. Future quality improvement initiatives should highlight the importance of high-quality color Doppler imaging and echocardiographic quantification to improve the accuracy, reproducibility, and quality of echocardiographic studies for valvular heart disease. © 2017 American Heart Association, Inc.

  18. 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography

    Energy Technology Data Exchange (ETDEWEB)

    Gabbour, Maya [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Schnell, Susanne [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Jarvis, Kelly [Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Robinson, Joshua D. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Pediatrics, Division of Pediatric Cardiology, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Pediatrics, Chicago, IL (United States); Markl, Michael [Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Northwestern University, Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL (United States); Rigsby, Cynthia K. [Ann and Robert H. Lurie Children' s Hospital of Chicago, Department of Medical Imaging 9, Chicago, IL (United States); Northwestern University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States)

    2015-06-15

    Doppler echocardiography (echo) is the reference standard for blood flow velocity analysis, and two-dimensional (2-D) phase-contrast magnetic resonance imaging (MRI) is considered the reference standard for quantitative blood flow assessment. However, both clinical standard-of-care techniques are limited by 2-D acquisitions and single-direction velocity encoding and may make them inadequate to assess the complex three-dimensional hemodynamics seen in congenital heart disease. Four-dimensional flow MRI (4-D flow) enables qualitative and quantitative analysis of complex blood flow in the heart and great arteries. The objectives of this study are to compare 4-D flow with 2-D phase-contrast MRI for quantification of aortic and pulmonary flow and to evaluate the advantage of 4-D flow-based volumetric flow analysis compared to 2-D phase-contrast MRI and echo for peak velocity assessment in children and young adults. Two-dimensional phase-contrast MRI of the aortic root, main pulmonary artery (MPA), and right and left pulmonary arteries (RPA, LPA) and 4-D flow with volumetric coverage of the aorta and pulmonary arteries were performed in 50 patients (mean age: 13.1 ± 6.4 years). Four-dimensional flow analyses included calculation of net flow and regurgitant fraction with 4-D flow analysis planes similarly positioned to 2-D planes. In addition, 4-D flow volumetric assessment of aortic root/ascending aorta and MPA peak velocities was performed and compared to 2-D phase-contrast MRI and echo. Excellent correlation and agreement were found between 2-D phase-contrast MRI and 4-D flow for net flow (r = 0.97, P < 0.001) and excellent correlation with good agreement was found for regurgitant fraction (r = 0.88, P < 0.001) in all vessels. Two-dimensional phase-contrast MRI significantly underestimated aortic (P = 0.032) and MPA (P < 0.001) peak velocities compared to echo, while volumetric 4-D flow analysis resulted in higher (aortic: P = 0.001) or similar (MPA: P = 0.98) peak

  19. Measurement of left ventricular torsion using block-matching-based speckle tracking for two-dimensional echocardiography

    Science.gov (United States)

    Sun, Feng-Rong; Wang, Xiao-Jing; Wu, Qiang; Yao, Gui-Hua; Zhang, Yun

    2013-01-01

    Left ventricular (LV) torsion is a sensitive and global index of LV systolic and diastolic function, but how to noninvasively measure it is challenging. Two-dimensional echocardiography and the block-matching based speckle tracking method were used to measure LV torsion. Main advantages of the proposed method over the previous ones are summarized as follows: (1) The method is automatic, except for manually selecting some endocardium points on the end-diastolic frame in initialization step. (2) The diamond search strategy is applied, with a spatial smoothness constraint introduced into the sum of absolute differences matching criterion; and the reference frame during the search is determined adaptively. (3) The method is capable of removing abnormal measurement data automatically. The proposed method was validated against that using Doppler tissue imaging and some preliminary clinical experimental studies were presented to illustrate clinical values of the proposed method.

  20. Effects of chronic severe pulmonary regurgitation and percutaneous valve repair on right ventricular geometry and contractility assessed by tissue Doppler echocardiography

    DEFF Research Database (Denmark)

    Kjaergaard, Jesper; Iversen, Kasper K; Vejlstrup, Niels G

    2010-01-01

    Pulmonary regurgitation (PR) following repair of right ventricular (RV) outflow obstruction is related to slowly progressive RV dilatation and heart failure and will eventually require surgical intervention, but optimal timing of pulmonary valve replacement is challenging. Tissue Doppler based...

  1. Dobutamine stress echocardiography: a review and update

    Directory of Open Access Journals (Sweden)

    Gilstrap LG

    2014-04-01

    Full Text Available Lauren Gray Gilstrap,1 R Sacha Bhatia,2 Rory B Weiner,3 David M Dudzinski3 1Division of Cardiology, Brigham and Women's Hospital, Boston, MA, USA; 2Institute for Health Systems Solutions, Women's College Hospital, Toronto, ON, Canada; 3Cardiology Division, Massachusetts General Hospital, Boston, MA, USA Abstract: Stress echocardiography is a noninvasive cardiovascular diagnostic test that provides functional and hemodynamic information in the assessment of a number of cardiac diseases. Performing stress echocardiography with a pharmacologic agent such as dobutamine allows for simulation of increased heart rate and increased myocardial physiologic demands in patients who may be unable to exercise due to musculoskeletal or pulmonary comorbidities. Dobutamine stress echocardiography (DSE, like exercise echocardiography, has found its primary application in ischemic heart disease, with roles in identification of obstructive epicardial coronary artery disease, detection of viable myocardium, and assessment of the efficacy of anti-ischemic medical therapy in patients with known coronary artery disease. DSE features prominently in the evaluation and management of valvular heart disease by helping to assess the effects of mitral and aortic stenoses, as well as a specific use in differentiating true severe valvular aortic stenosis from pseudostenosis that may occur in the setting of left ventricular systolic dysfunction. DSE is generally well tolerated, and its side effects and contraindications generally relate to consequences of excess inotropic and/or chronotropic stimulation of the heart. The aim of this paper is to review the indications, contraindications, advantages, disadvantages, and risks of DSE. Keywords: stress echocardiography, dobutamine, coronary artery disease, myocardial ischemia

  2. Wave plus current over a ripple-covered bed

    DEFF Research Database (Denmark)

    Fredsøe, Jørgen; Andersen, Ken Haste; Sumer, B. Mutlu

    1999-01-01

    This paper concerns the combined wave and current boundary layer flow over a ripple-covered bed, The study comprises experiments as well as a numerical modelling study: the experimental part comprises laser Doppler anemometry (LDA) velocity and turbulence measurements, and a flow-visualization st......This paper concerns the combined wave and current boundary layer flow over a ripple-covered bed, The study comprises experiments as well as a numerical modelling study: the experimental part comprises laser Doppler anemometry (LDA) velocity and turbulence measurements, and a flow......-visualization study in the laboratory with ripples, 22 cm in length, and 3.5 cm in height. One wave-alone, three current-alone, and three combined waves and current tests were conducted. The wave-velocity-to-current-velocity ratio ranges from 1 to 2.4. The orbiral-amplitude-ro-ripple-length ratio (at the bed) is 0.......41. The effect of superimposing waves on a current is to displace the velocity profile to higher elevations. The velocity profiles exhibit two "logarithmic layers", one associated with the actual roughness of the bed (the actual ripple roughness), and the other with the apparent roughness induced by the waves...

  3. Determining the near-surface current profile from measurements of the wave dispersion relation

    Science.gov (United States)

    Smeltzer, Benjamin; Maxwell, Peter; Aesøy, Eirik; Ellingsen, Simen

    2017-11-01

    The current-induced Doppler shifts of waves can yield information about the background mean flow, providing an attractive method of inferring the current profile in the upper layer of the ocean. We present measurements of waves propagating on shear currents in a laboratory water channel, as well as theoretical investigations of inversion techniques for determining the vertical current structure. Spatial and temporal measurements of the free surface profile obtained using a synthetic Schlieren method are analyzed to determine the wave dispersion relation and Doppler shifts as a function of wavelength. The vertical current profile can then be inferred from the Doppler shifts using an inversion algorithm. Most existing algorithms rely on a priori assumptions of the shape of the current profile, and developing a method that uses less stringent assumptions is a focus of this study, allowing for measurement of more general current profiles. The accuracy of current inversion algorithms are evaluated by comparison to measurements of the mean flow profile from particle image velocimetry (PIV), and a discussion of the sensitivity to errors in the Doppler shifts is presented.

  4. "3D fusion" echocardiography improves 3D left ventricular assessment: comparison with 2D contrast echocardiography.

    Science.gov (United States)

    Augustine, Daniel; Yaqub, Mohammad; Szmigielski, Cezary; Lima, Eduardo; Petersen, Steffen E; Becher, Harald; Noble, J Alison; Leeson, Paul

    2015-02-01

    Three-dimensional fusion echocardiography (3DFE) is a novel postprocessing approach that utilizes imaging data acquired from multiple 3D acquisitions. We assessed image quality, endocardial border definition, and cardiac wall motion in patients using 3DFE compared to standard 3D images (3D) and results obtained with contrast echocardiography (2DC). Twenty-four patients (mean age 66.9 ± 13 years, 17 males, 7 females) undergoing 2DC had three, noncontrast, 3D apical volumes acquired at rest. Images were fused using an automated image fusion approach. Quality of the 3DFE was compared to both 3D and 2DC based on contrast-to-noise ratio (CNR) and endocardial border definition. We then compared clinical wall-motion score index (WMSI) calculated from 3DFE and 3D to those obtained from 2DC images. Fused 3D volumes had significantly improved CNR (8.92 ± 1.35 vs. 6.59 ± 1.19, P echocardiography (1.06 ± 0.09 vs. 1.07 ± 0.15, P = 0.69), whereas unfused images produced significantly more variable results (1.19 ± 0.30). This was confirmed by a better intraclass correlation coefficient (ICC 0.72; 95% CI 0.32-0.88) relative to comparisons with unfused images (ICC 0.56; 95% CI 0.02-0.81). 3DFE significantly improves left ventricular image quality compared to unfused 3D in a patient population and allows noncontrast assessment of wall motion that approaches that achieved with 2D contrast echocardiography. © 2014, Wiley Periodicals, Inc.

  5. Gravitational-wave bursts from the nuclei of distant galaxies and quasars: proposal for detection using Doppler tracking of interplanetary spacecraft

    International Nuclear Information System (INIS)

    Thorne, K.S.; Braginsky, V.B.

    1976-01-01

    It is likely that supermassive black holes (Mapprox. =10 6 to 10 10 M/sub sun/) exist in the nuclei of many quasars and galaxies. The collapse which forms these holes and subsequent collisions between them should produce strong, broad-band bursts of gravitational waves: for a source of mass M at the Hubble distance of approx.10 10 light-years, the dimensionless amplitude would be h approx. 2 x 10 -17 x (M/10 6 M/sub sun/), and the duration of the burst would be tauapprox. (90 s) x (M/10 6 M/sub sun/). Such bursts might arrive at Earth as often as 50 times per year: or as rarely as once each 300 years. The detection of such bursts may be possible within the next few years using dual-frequency Doppler tracking of interplanetary spacecraft

  6. Apical hypertrophy associated with rapid T wave inversion on the electrocardiogram.

    Science.gov (United States)

    Yamanari, H; Saito, D; Mikio, K; Nakamura, K; Nanba, T; Morita, H; Mizuo, K; Sato, T; Ohe, T

    1995-01-01

    A 53-year-old man who had no chest pain and no family history of heart disease demonstrated a rapid T wave change on an electrocardiogram, from a positive T wave to a giant negative T wave, within 1 year. Echocardiography showed no left ventricular hypertrophy before or after the T wave change. Cine-magnetic resonance imaging revealed focal apical hypertrophy after the appearance of the giant negative T wave. Although T wave inversions sometimes develop within a short period in patients with hypertrophic cardiomyopathy, they are rare in a patient without hypertension or chest pain.

  7. Head-to-head comparison of peak supine bicycle exercise echocardiography and treadmill exercise echocardiography at peak and at post-exercise for the detection of coronary artery disease.

    Science.gov (United States)

    Peteiro, Jesús; Bouzas-Mosquera, Alberto; Estevez, Rodrigo; Pazos, Pablo; Piñeiro, Miriam; Castro-Beiras, Alfonso

    2012-03-01

    Supine bicycle exercise (SBE) echocardiography and treadmill exercise (TME) echocardiography have been used for evaluation of coronary artery disease (CAD). Although peak imaging acquisition has been considered unfeasible with TME, higher sensitivity for the detection of CAD has been recently found with this method compared with post-TME echocardiography. However, peak TME echocardiography has not been previously compared with the more standardized peak SBE echocardiography. The aim of this study was to compare peak TME echocardiography, peak SBE echocardiography, and post-TME echocardiography for the detection of CAD. A series of 116 patients (mean age, 61 ± 10 years) referred for evaluation of CAD underwent SBE (starting at 25 W, with 25-W increments every 2-3 min) and TME with peak and postexercise imaging acquisition, in a random sequence. Digitized images at baseline, at peak TME, after TME, and at peak SBE were interpreted in a random and blinded fashion. All patients underwent coronary angiography. Maximal heart rate was higher during TME, whereas systolic blood pressure was higher during SBE, resulting in similar rate-pressure products. On quantitative angiography, 75 patients had coronary stenosis (≥50%). In these patients, wall motion score indexes at maximal exercise were higher at peak TME (median, 1.45; interquartile range [IQR], 1.13-1.75) than at peak SBE (median, 1.25; IQR, 1.0-1.56) or after TME (median, 1.13; IQR, 1.0-1.38) (P = .002 between peak TME and peak SBE imaging, P peak TME (median, 5; IQR, 2-12) compared with peak SBE (median, 3; IQR, 0-8) or after TME (median, 2; IQR, 0-4) (P peak TME and peak SBE imaging, P peak TME, peak SBE, and post-TME echocardiography for CAD was 84%, 75%, and 60% (P = .001 between post-TME and peak TME echocardiography, P = .055 between post-TME and peak SBE echocardiography), with specificity of 63%, 80%, and 78%, respectively (P = NS) and accuracy of 77%, 77%, and 66%, respectively (P = NS). Peak TME

  8. Application of scanning laser Doppler vibrometry for delamination detection in composite structures

    Science.gov (United States)

    Kudela, Pawel; Wandowski, Tomasz; Malinowski, Pawel; Ostachowicz, Wieslaw

    2017-12-01

    In this paper application of scanning laser Doppler vibrometry for delamination detection in composite structures was presented. Delamination detection was based on a guided wave propagation method. In this papers results from numerical and experimental research were presented. In the case of numerical research, the Spectral Element Method (SEM) was utilized, in which a mesh was composed of 3D spectral elements. SEM model included also a piezoelectric transducer. In the experimental research guided waves were excited using the piezoelectric transducer whereas the sensing process was conducted using scanning laser Doppler vibrometer (SLDV). Analysis of guided wave propagation and its interaction with delamination was based on a full wavefield approach. Attention was focused on interactions of guided waves with delamination manifested by A0 mode reflection, A0 mode entrapment, and S0/A0 mode conversion. Delamination was simulated by a teflon insert located between plies of composite material. Results of interaction with symmetrically and nonsymmetrical placed delamination (in respect to the composite sample thickness) were presented. Moreover, the authors investigated different size of delaminations. Damage detection was based on a new signal processing algorithm proposed by the authors. In this approach the weighted RMS was utilized selectively. It means that the summation in RMS formula was performed only for a specially selected time instances. Results for simple composite panels, panel with honeycomb core, and real stiffened composite panel from the aircraft were presented.

  9. Increased left ventricular mass index is present in patients with type 2 diabetes without ischemic heart disease

    DEFF Research Database (Denmark)

    Seferovic, Jelena P; Tesic, Milorad; Seferovic, Petar M

    2018-01-01

    , stress echocardiography, transthoracic 2D Doppler and tissue Doppler echocardiography were performed. Multivariable logistic regression was used to determine the independent association with T2DM. Linear regression models and Pearson's correlation were used to assess the correlations between LVMI.......029). A positive correlation of LVMI was found with fasting glucose (p 

  10. Spin-wave propagation and spin-polarized electron transport in single-crystal iron films

    Science.gov (United States)

    Gladii, O.; Halley, D.; Henry, Y.; Bailleul, M.

    2017-11-01

    The techniques of propagating spin-wave spectroscopy and current-induced spin-wave Doppler shift are applied to a 20-nm-thick Fe/MgO(001) film. The magnetic parameters extracted from the position of the spin-wave resonance peaks are very close to those tabulated for bulk iron. From the zero-current propagating wave forms, a group velocity of 4 km/s and an attenuation length of about 6 μ m are extracted for 1.6-μ m -wavelength spin wave at 18 GHz. From the measured current-induced spin-wave Doppler shift, we extract a surprisingly high degree of spin polarization of the current of 83 % , which constitutes the main finding of this work. This set of results makes single-crystalline iron a promising candidate for building devices utilizing high-frequency spin waves and spin-polarized currents.

  11. Echocardiography in the flight program

    Science.gov (United States)

    Charles, John B.; Bungo, Michael W.; Mulvagh, Sharon L.

    1991-01-01

    Observations on American and Soviet astronauts have documented the association of changes in cardiovascular function during orthostasis with space flight. A basic understanding of the cardiovascular changes occurring in astronauts requires the determination of cardiac output and total peripheral vascular resistance as a minimum. In 1982, we selected ultrasound echocardiography as our means of acquiring this information. Ultrasound offers a quick, non-invasive and accurate means of determining stroke volume which, when combined with the blood pressure and heart rate measurements of the stand test, allows calculation of changes in peripheral vascular resistance, the body's major response to orthostatic stress. The history of echocardiography in the Space Shuttle Program is discussed and the results are briefly presented.

  12. Arterial Stiffness and its Correlation with the Extent of Coronary Artery Disease

    Directory of Open Access Journals (Sweden)

    Hourak Poorzand

    2018-06-01

    Full Text Available Introduction: Coronary artery disease secondary to atherosclerosis is the most common cause of mortality. Coronary angiography is the most precise method for determining the extent of disease in the coronary vascular bed. Arterial stiffness has been proposed as a marker of atherosclerosis in some studies. One of the noninvasive methods for the determination of arterial stiffness is Doppler echocardiography. In this study, we aimed to find the correlation between arterial stiffness as measured by echocardiography and the extent of coronary artery disease as evaluated through angiography. Materials and Methods: Aortic pulse wave velocity (APWV was measured by using the Doppler method in 70 patients, who were candidates for coronary angiography. The extent of coronary artery disease was determined quantitatively in terms of Friesinger index and semi-quantitatively as the number of vessels with stenosis of over 50%. Then, the correlation between arterial stiffness and these factors was evaluated. Results: The mean APWV was 9.1±5 m/s. There was a direct relationship between APWV and Friesinger index, which was not statistically significant (P=0.67. The mean APWV for patients with one-vessel disease was 4.4±1.8 m/s, while it was 9.9±3.6 m/s in patients with two and 7.9±4 m/s in three-vessel disease which did not show statistically significant difference. Conclusion: Doppler echocardiography to measure APWV was not considered as a promising tool to predict the extent of coronary artery disease.

  13. 3D Harmonic Echocardiography:

    NARCIS (Netherlands)

    M.M. Voormolen (Marco)

    2007-01-01

    textabstractThree dimensional (3D) echocardiography has recently developed from an experimental technique in the ’90 towards an imaging modality for the daily clinical practice. This dissertation describes the considerations, implementation, validation and clinical application of a unique

  14. Echocardiography in Infective Endocarditis: State of the Art.

    Science.gov (United States)

    Afonso, Luis; Kottam, Anupama; Reddy, Vivek; Penumetcha, Anirudh

    2017-10-25

    In this review, we examine the central role of echocardiography in the diagnosis, prognosis, and management of infective endocarditis (IE). 2D transthoracic echocardiography (TTE) and transesophageal echocardiography TEE have complementary roles and are unequivocally the mainstay of diagnostic imaging in IE. The advent of 3D and multiplanar imaging have greatly enhanced the ability of the imager to evaluate cardiac structure and function. Technologic advances in 3D imaging allow for the reconstruction of realistic anatomic images that in turn have positively impacted IE-related surgical planning and intervention. CT and metabolic imaging appear to be emerging as promising ancillary diagnostic tools that could be deployed in select scenarios to circumvent some of the limitations of echocardiography. Our review summarizes the indispensable and central role of various echocardiographic modalities in the management of infective endocarditis. The complementary role of 2D TTE and TEE are discussed and areas where 3D TEE offers incremental value highlighted. An algorithm summarizing a contemporary approach to the workup of endocarditis is provided and major societal guidelines for timing of surgery are reviewed.

  15. Dobutamine Stress Echocardiography and Tissue Synchronization Imaging

    Science.gov (United States)

    Tas, Hakan; Gundogdu, Fuat; Gurlertop, Yekta; Karakelleoglu, Sule

    2008-01-01

    Dobutamine stress echocardiography has emerged as a reliable method for the diagnosis of coronary artery disease and the management of its treatment. Several studies have shown that that this technique works with 80–85% accuracy in comparison with other imaging methods. There are few studies aimed at developing the clinical utility of dobutamine stress echocardiography for the evaluation of normal and abnormal segments that result from dobutamine stress with Tissue Synchronization Imaging. PMID:25610034

  16. Methodological approach for the assessment of ultrasound reproducibility of cardiac structure and function: a proposal of the study group of Echocardiography of the Italian Society of Cardiology (Ultra Cardia SIC) Part I

    Science.gov (United States)

    2011-01-01

    When applying echo-Doppler imaging for either clinical or research purposes it is very important to select the most adequate modality/technology and choose the most reliable and reproducible measurements. Quality control is a mainstay to reduce variability among institutions and operators and must be obtained by using appropriate procedures for data acquisition, storage and interpretation of echo-Doppler data. This goal can be achieved by employing an echo core laboratory (ECL), with the responsibility for standardizing image acquisition processes (performed at the peripheral echo-labs) and analysis (by monitoring and optimizing the internal intra- and inter-reader variability of measurements). Accordingly, the Working Group of Echocardiography of the Italian Society of Cardiology decided to design standardized procedures for imaging acquisition in peripheral laboratories and reading procedures and to propose a methodological approach to assess the reproducibility of echo-Doppler parameters of cardiac structure and function by using both standard and advanced technologies. A number of cardiologists experienced in cardiac ultrasound was involved to set up an ECL available for future studies involving complex imaging or including echo-Doppler measures as primary or secondary efficacy or safety end-points. The present manuscript describes the methodology of the procedures (imaging acquisition and measurement reading) and provides the documentation of the work done so far to test the reproducibility of the different echo-Doppler modalities (standard and advanced). These procedures can be suggested for utilization also in non referall echocardiographic laboratories as an "inside" quality check, with the aim at optimizing clinical consistency of echo-Doppler data. PMID:21943283

  17. Evaluation of aortic regurgitation using cine magnetic resonance imaging

    International Nuclear Information System (INIS)

    Tamai, Takuya; Konishi, Tokuji; Okamoto, Shinya; Sakuma, Hajime; Takeda, Kan; Nakano, Takeshi

    1993-01-01

    Cine magnetic resonance imaging (MRI) was used to assess aortic regurgitation (AR) in 13 patients with valvular disease and 3 normal subjects, and the results were compared to color Doppler flow mapping findings. AR produced a signal void in the left ventricle during the diastolic phase in all patients by MRI. There were no false positive or negative results compared with echocardiographic findings. Visual grading of cine MRI gave results similar to color flow Doppler echocardiography (88%). The distance and the area of aortic regurgitation using MRI correlated well with color Doppler flow mapping (r=0.82 and 0.88). However, measurements of distance and area by color flow Doppler tended to be larger than those by cine MRI. With current techniques echocardiography may overestimate the severity of AR as compared with cine MRI. In addition, MRI gives clinically useful information in patients in whom transthoracic Doppler echocardiography is not adequate. (author)

  18. Validation of noninvasive indices of global systolic function in patients with normal and abnormal loading conditions: a simultaneous echocardiography pressure-volume catheterization study.

    Science.gov (United States)

    Yotti, Raquel; Bermejo, Javier; Benito, Yolanda; Sanz-Ruiz, Ricardo; Ripoll, Cristina; Martínez-Legazpi, Pablo; del Villar, Candelas Pérez; Elízaga, Jaime; González-Mansilla, Ana; Barrio, Alicia; Bañares, Rafael; Fernández-Avilés, Francisco

    2014-01-01

    Noninvasive indices based on Doppler echocardiography are increasingly used in clinical cardiovascular research to evaluate left ventricular global systolic chamber function. Our objectives were to clinically validate ultrasound-based methods of global systolic chamber function to account for differences between patients in conditions of abnormal load, and to assess their sensitivity to load confounders. Twenty-seven patients (8 dilated cardiomyopathy, 10 normal ejection fraction, and 9 end-stage liver disease) underwent simultaneous echocardiography and left heart catheterization with pressure-conductance instrumentation. The reference index, maximal elastance (Emax), was calculated from pressure-volume loop data obtained during acute inferior vena cava occlusion. A wide range of values were observed for left ventricular systolic chamber function (Emax: 2.8±1.0 mm Hg/mL), preload, and afterload. Among the noninvasive indices tested, the peak ejection intraventricular pressure difference showed the best correlation with Emax (R=0.75). A significant but weaker correlation with Emax was observed for ejection fraction (R=0.41), midwall fractional shortening (R=0.51), global circumferential strain (R=-0.53), and strain rate (R=-0.46). Longitudinal strain and strain rate failed to correlate with Emax, as did noninvasive single-beat estimations of this index. Principal component and multiple regression analyses demonstrated that peak ejection intraventricular pressure difference was less sensitive to load, whereas ejection fraction and longitudinal strain and strain rate were heavily influenced by afterload. Current ultrasound methods have limited accuracy to characterize global left ventricular systolic chamber function in a given patient. The Doppler-derived peak ejection intraventricular pressure difference should be preferred for this purpose because it best correlates with the reference index and is more robust in conditions of abnormal load.

  19. Fresh look at the doppler changes in pregnancies with placental-based complications

    Directory of Open Access Journals (Sweden)

    S Dikshit

    2011-01-01

    Full Text Available Placental-based complications of pregnancy can be classified as acute and chronic. An example of acute placental complication is abruptio placenta. The chronic placental complications include pregnancy induced hypertension (PIH and idiopathic Intrauterine growth restriction (IUGR. The fetus is at risk for perinatal complications in both acute and chronic conditions. Here we take a look at the natural history of the Doppler parameters in chronic conditions. The techniques used for assessing the fetal well-being include, clinical methods, biophysical tests, conventional ultrasonography, and fetal Doppler studies. Arterial Doppler studies are used to assess the well-being of the fetus and to determine the timing of delivery. However, arterial Dopplers predict only the subset of fetuses at risk of having perinatal complications. Venous Dopplers have been used to improve upon the prognostication. However, by the time the commonly used venous Doppler signs, that is, ′A′ wave reversal in ductus venosus (DV is present, the fetus is likely to be already compromised. The fetus tries to adapt to the environment of deprivation by making a series of changes in the umbilical artery circulation, cerebral circulation, and hepatic circulation. As a result of these adaptations, the fetus overcomes the state of chronic hypoxia. This article takes a look at these changes and also the effect of these adaptations. It is suggested that serial comparisons of the venous flow characteristics of the DV and inferior vena cava (IVC can provide an early indication of the impending decompensation and can be used to predict the time the delivery.

  20. Role of imaging techniques in the evaluation of cardiovascular drugs

    International Nuclear Information System (INIS)

    Sugishita, Yasuro; Matsuda, Mitsuo; Ajisaka, Ryuichi

    1985-01-01

    In order to investigate the role of imaging in the evaluation of medical treatment in heart diseases, radionuclide angiocardiography, echocardiography and Doppler echocardiography were applied in the cases of various kinds of heart diseases. Acute and chronic effects of antianginal drugs (nitrates, calcium antagonists and beta-blockers) could be evaluated by exercise radionuclide angiocardiography or exercise echocardiography in the cases of effort angina. The effects of the drugs changing myocardial contractility, preload or afterload could be evaluated by echocardiography in various kinds of heart diseases, including valvular heart biseases. The effect of calcium antagonists in improving diastolic function in hypertrophic cardiomyopathy could be evaluated by echocardiography or Doppler echocardiography. In conclusion, imaging techniqus are valuable and useful methods to evaluate the effects of cardiovascular drugs, by offering various informations. (author)

  1. High PRF ultrafast sliding compound doppler imaging: fully qualitative and quantitative analysis of blood flow

    Science.gov (United States)

    Kang, Jinbum; Jang, Won Seuk; Yoo, Yangmo

    2018-02-01

    Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles (N) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (-12° to 12°) with L of 1-9, and the results were found to be comparable to those of the UCDI method (L  =  N  =  9), i.e.  ⩽0.24 cm s-1, for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L

  2. High PRF ultrafast sliding compound doppler imaging: fully qualitative and quantitative analysis of blood flow.

    Science.gov (United States)

    Kang, Jinbum; Jang, Won Seuk; Yoo, Yangmo

    2018-02-09

    Ultrafast compound Doppler imaging based on plane-wave excitation (UCDI) can be used to evaluate cardiovascular diseases using high frame rates. In particular, it provides a fully quantifiable flow analysis over a large region of interest with high spatio-temporal resolution. However, the pulse-repetition frequency (PRF) in the UCDI method is limited for high-velocity flow imaging since it has a tradeoff between the number of plane-wave angles (N) and acquisition time. In this paper, we present high PRF ultrafast sliding compound Doppler imaging method (HUSDI) to improve quantitative flow analysis. With the HUSDI method, full scanline images (i.e. each tilted plane wave data) in a Doppler frame buffer are consecutively summed using a sliding window to create high-quality ensemble data so that there is no reduction in frame rate and flow sensitivity. In addition, by updating a new compounding set with a certain time difference (i.e. sliding window step size or L), the HUSDI method allows various Doppler PRFs with the same acquisition data to enable a fully qualitative, retrospective flow assessment. To evaluate the performance of the proposed HUSDI method, simulation, in vitro and in vivo studies were conducted under diverse flow circumstances. In the simulation and in vitro studies, the HUSDI method showed improved hemodynamic representations without reducing either temporal resolution or sensitivity compared to the UCDI method. For the quantitative analysis, the root mean squared velocity error (RMSVE) was measured using 9 angles (-12° to 12°) with L of 1-9, and the results were found to be comparable to those of the UCDI method (L  =  N  =  9), i.e.  ⩽0.24 cm s -1 , for all L values. For the in vivo study, the flow data acquired from a full cardiac cycle of the femoral vessels of a healthy volunteer were analyzed using a PW spectrogram, and arterial and venous flows were successfully assessed with high Doppler PRF (e.g. 5 kHz at L

  3. Exercise right heart catheterization for pulmonary hypertension identified on screening echocardiography in adult survivors of childhood cancer: A report from the St. Jude Lifetime Cohort.

    Science.gov (United States)

    Armstrong, Gregory T; Tolle, James J; Piana, Robert; Santucci, Aimee; Leathers, James; Ness, Kirsten K; Mulrooney, Daniel A; Green, Daniel M; Joshi, Vijaya M; Robison, Leslie L; Hudson, Melissa M; Lenihan, Daniel

    2018-01-01

    Pulmonary hypertension, determined noninvasively by tricuspid regurgitant jet velocity on Doppler echocardiography, was previously identified in 25% of long-term survivors who received chest-directed radiotherapy. To validate noninvasively defined pulmonary hypertension, survivors (mean age 48 years), exposed to chest radiotherapy, underwent right heart catheterization with planned cardiopulmonary exercise testing during catheterization. Eight participants had an elevated mean pulmonary artery pressure at rest (≥25 mm Hg) or with subsequent exercise (>30 mm Hg), evidence of hemodynamically confirmed pulmonary hypertension by right heart catheterization. Cardiopulmonary exercise testing further defined the magnitude and etiology of cardiopulmonary limitations in this life-threatening late effect. © 2017 Wiley Periodicals, Inc.

  4. Detection of Moving Targets Based on Doppler Spectrum Analysis Technique for Passive Coherent Radar

    Directory of Open Access Journals (Sweden)

    Zhao Yao-dong

    2013-06-01

    Full Text Available A novel method of moving targets detection taking Doppler spectrum analysis technique for Passive Coherent Radar (PCR is provided. After dividing the receiving signals into segments as pulse series, it utilizes the technique of pulse compress and Doppler processing to detect and locate the targets. Based on the algorithm for Pulse-Doppler (PD radar, the equipollence between continuous and pulsed wave in match filtering is proved and details of this method are introduced. To compare it with the traditional method of Cross-Ambiguity Function (CAF calculation, the relationship and mathematical modes of them are analyzed, with some suggestions on parameters choosing. With little influence to the gain of targets, the method can greatly promote the processing efficiency. The validity of the proposed method is demonstrated by offline processing real collected data sets and simulation results.

  5. The Role of Focused Echocardiography in Pediatric Intensive Care: A Critical Appraisal

    Science.gov (United States)

    Gaspar, Heloisa Amaral; Morhy, Samira Saady

    2015-01-01

    Echocardiography is a key tool for hemodynamic assessment in Intensive Care Units (ICU). Focused echocardiography performed by nonspecialist physicians has a limited scope, and the most relevant parameters assessed by focused echocardiography in Pediatric ICU are left ventricular systolic function, fluid responsiveness, cardiac tamponade and pulmonary hypertension. Proper ability building of pediatric emergency care physicians and intensivists to perform focused echocardiography is feasible and provides improved care of severely ill children and thus should be encouraged. PMID:26605333

  6. Echocardiography in Ebstein's anomaly

    NARCIS (Netherlands)

    W.J. Gussenhoven (Wilhelmina Johanna)

    1984-01-01

    textabstractIn this thesis the value of echocardiography is evaluated for the diagnosis of Ebstein's anomaly of the tricuspid valve. This congenital heart defect, first described in 1866 by Wilhelm Ebstein, is characterized by an apical displacement of the septal and inferior tricuspid valve

  7. Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass.

    Science.gov (United States)

    Suematsu, Y; Takamoto, S; Ohtsuka, T

    2001-12-01

    No accepted approach exists for the intraoperative evaluation of the quality of coronary arteries and the technical adequacy of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass. We assessed the accuracy of high-frequency epicardial echocardiography and power Doppler imaging in evaluating coronary arteries during coronary artery bypass grafting without cardiopulmonary bypass. To validate measurements of coronary arteries and graft anastomoses by high-frequency epicardial echocardiography and power Doppler imaging, we compared luminal diameters determined by these methods with diameters determined histologically in a study of off-pump coronary artery bypass grafting in 20 dogs. Technical errors were deliberately created in 10 grafts (stenosis group). The results of these animal validation studies showed that the maximum luminal diameters of coronary arteries and graft anastomoses measured by high-frequency epicardial echocardiography (HEE) and power Doppler imaging (PDI) correlated well with the histologic measurements: HEE = 1.027 x Histologic measurements + 0.005 (P anastomoses were examined intraoperatively by high-frequency epicardial echocardiography and power Doppler imaging, and luminal diameters determined by power Doppler imaging were compared with those determined by postoperative coronary angiography. The results demonstrated that graft anastomosis by power Doppler imaging correlated well with the angiographic measurements: PDI = 1.018 x Angiographic measurements - 0.106 (P anastomoses and can detect technical errors and inadequacies during coronary artery bypass grafting without cardiopulmonary bypass.

  8. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    International Nuclear Information System (INIS)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions

  9. (abstract) Tropospheric Calibration for the Mars Observer Gravity Wave Experiment

    Science.gov (United States)

    Walter, Steven J.; Armstrong, John

    1994-01-01

    In spring 1993, microwave radiometer-based tropospheric calibration was provided for the Mars Observer gravitational wave search. The Doppler shifted X-band radio signals propagating between Earth and the Mars Observer satellite were precisely measured to determine path length variations that might signal passage of gravitational waves. Experimental sensitivity was restricted by competing sources of variability in signal transit time. Principally, fluctuations in the solar wind and ionospheric plasma density combined with fluctions in tropospheric refractivity determined the detection limit. Troposphere-induced path delay fluctions are dominated by refractive changes caused by water vapor inhomogeneities blowing through the signal path. Since passive microwave remote sensing techniques are able to determine atmospheric propagation delays, radiometer-based tropospheric calibration was provided at the Deep Space Network Uranus tracking site (DSS-15). Two microwave water vapor radiometers (WVRs), a microwave temperature profiler (MTP), and a ground based meterological station were deployed to determine line-of-sight vapor content and vertical temperature profile concurrently with Mars Observer tracking measurements. This calibration system provided the capability to correct Mars Observer Doppler data for troposphere-induced path variations. We present preliminary analysis of the Doppler and WVR data sets illustrating the utility of WVRs to calibrate Doppler data. This takes an important step toward realizing the ambitious system required to support future Ka-band Cassini satellite gravity wave tropospheric calibration system.

  10. A review of results of the international ionospheric Doppler sounder network

    Czech Academy of Sciences Publication Activity Database

    Laštovička, Jan; Chum, Jaroslav

    2017-01-01

    Roč. 60, č. 8 (2017), s. 1629-1643 ISSN 0273-1177 R&D Projects: GA ČR(CZ) GC15-07281J Institutional support: RVO:68378289 Keywords : ionospheric Doppler shift sounding * gravity waves * infrasound * solar forcing Subject RIV: DG - Athmosphere Sciences, Meteorology OBOR OECD: Meteorology and atmospheric sciences Impact factor: 1.401, year: 2016 http://www.sciencedirect.com/science/article/pii/S0273117717300790?via%3Dihub

  11. A case of complete double aortic arch visualized by transthoracic echocardiography.

    Science.gov (United States)

    Saito, Naka; Kato, Shingo; Saito, Noritaka; Nakachi, Tatsuya; Fukui, Kazuki; Iwasawa, Tae; Kosuge, Masami; Kimura, Kazuo

    2017-08-01

    A case of double aortic arch that was well visualized using transthoracic echocardiography is reported. A 38-year-old man underwent transthoracic echocardiography for the evaluation of dyspnea. A suprasternal view of transthoracic echocardiography showed the ascending aorta bifurcate to left and right aortic arches, with blood flow from the ascending aorta to bilateral aortic arches. The diagnosis of right side-dominant double aortic arch was made, and the patient's symptom was conceivably related to compression of the trachea due to a vascular ring. This report indicates the potential usefulness of transthoracic echocardiography for noninvasive detection of double aortic arch in adults. © 2017, Wiley Periodicals, Inc.

  12. Doppler and time-travel broadening in ICR plasma isotope separation

    International Nuclear Information System (INIS)

    Karchevskii, A.I.; Potanin, E.P.

    1994-01-01

    Isotopically-selective ion-cyclotron resonance (ICR) heating is one of the most promising plasma isotope separation methods. The separation degree of ICR separation in a plasma depends on the resonance heating selectivity. The selectivity is due to the isotopically-adjacent accelerated ions resonance curve overlapping and therefore, is determined by the width of the resonance curves. In the case of a collisionless plasma in an ideal homogeneous longitudinal magnetic field, the line broadening is mainly determined by Doppler and time-travel effects. These effects differ in nature, and one has some difficulties in distinguishing them when interpreting the resonance curves because both broadenings depend on ion axial velocities. We consider the simplest case: the extrenal heating alternating electric field does not depend on the axial coordinate (the wave number γ = 0). Hence, in this case the Doppler effect does not occur

  13. Targeted neonatal echocardiography services: need for standardized training and quality assurance.

    Science.gov (United States)

    Finan, Emer; Sehgal, Arvind; Khuffash, Afif El; McNamara, Patrick J

    2014-10-01

    Targeted neonatal echocardiography refers to a focused assessment of myocardial performance and hemodynamics directed by a specific clinical question. It has become the standard of care in many parts of the world, but practice is variable, and there has been a lack of standardized training and evaluation to date. Targeted neonatal echocardiography was first introduced to Canada in 2006. The purpose of this study was to examine the characteristics of targeted neonatal echocardiography practice and training methods in Canadian neonatal intensive care units (NICUs). A total of 142 Canadian neonatologists were invited to participate in an online survey, which was conducted in September 2010. The survey consisted of questions related to the availability of targeted neonatal echocardiography, clinical indications, benefits and risks, and training methods. The overall survey response rate was 65%. Forty-eight respondents (34%) indicated that targeted neonatal echocardiography was available in their units, and the program was introduced within the preceding 1 to 5 years. In centers where it was unavailable, lack of on-site echocardiography expertise was cited as the major barrier to implementation. The most common indications for targeted neonatal echocardiography included evaluation of a hemodynamically significant ductus arteriosus, systemic or pulmonary blood flow, and response to cardiovascular treatments. Only 27% of respondents, working in centers where targeted neonatal echocardiography existed, actually performed the studies themselves; most individuals completed 11 to 20 studies per month. Almost half of the respondents said that training was available in their institutions, but methods of training and evaluation were inconsistent. Eighty-seven percent of respondents reported no formalized process for assessment of ongoing competency after the initial training period. Targeted neonatal echocardiography is becoming more widely available and is gaining acceptance in

  14. Dual-Doppler Feasibility Study

    Science.gov (United States)

    Huddleston, Lisa L.

    2012-01-01

    When two or more Doppler weather radar systems are monitoring the same region, the Doppler velocities can be combined to form a three-dimensional (3-D) wind vector field thus providing for a more intuitive analysis of the wind field. A real-time display of the 3-D winds can assist forecasters in predicting the onset of convection and severe weather. The data can also be used to initialize local numerical weather prediction models. Two operational Doppler Radar systems are in the vicinity of Kennedy Space Center (KSC) and Cape Canaveral Air Force Station (CCAFS); these systems are operated by the 45th Space Wing (45 SW) and the National Weather Service Melbourne, Fla. (NWS MLB). Dual-Doppler applications were considered by the 45 SW in choosing the site for the new radar. Accordingly, the 45th Weather Squadron (45 WS), NWS MLB and the National Aeronautics and Space Administration tasked the Applied Meteorology Unit (AMU) to investigate the feasibility of establishing dual-Doppler capability using the two existing systems. This study investigated technical, hardware, and software requirements necessary to enable the establishment of a dual-Doppler capability. Review of the available literature pertaining to the dual-Doppler technique and consultation with experts revealed that the physical locations and resulting beam crossing angles of the 45 SW and NWS MLB radars make them ideally suited for a dual-Doppler capability. The dual-Doppler equations were derived to facilitate complete understanding of dual-Doppler synthesis; to determine the technical information requirements; and to determine the components of wind velocity from the equation of continuity and radial velocity data collected by the two Doppler radars. Analysis confirmed the suitability of the existing systems to provide the desired capability. In addition, it is possible that both 45 SW radar data and Terminal Doppler Weather Radar data from Orlando International Airport could be used to alleviate any

  15. Ecocardiografia por Doppler tecidual no diagnóstico de rejeição após transplante cardíaco Ecocardiografía con Doppler tisular en el diagnóstico de rechazo después de transplante cardíaco Tissue doppler echocardiography in the diagnosis of heart transplantation rejection

    Directory of Open Access Journals (Sweden)

    Marcos Valério Coimbra Resende

    2011-07-01

    Full Text Available FUNDAMENTO: A biópsia endomiocárdica (BEM é o método padrão-ouro para o diagnóstico de rejeição celular (RC após transplante cardíaco (TC. OBJETIVO: Testar a hipótese de que o exame de imagem por Doppler tecidual (IDT pode detectar RC > 3A e agregar informação diagnóstica, comparado ao Doppler convencional. MÉTODOS: Cinquenta e quatro pacientes com TC foram submetidos à BEM e estudo ecocardiográfico através de IDT em até 24 horas. Comparamos os pacientes com TC e RC > 3A com pacientes com TC e RC 3A em 39/129 (30,2% das BEM. O melhor preditor isolado para o diagnóstico de RC foi a a'LAT, com sensibilidade de 76,3%, especificidade de 73,8% (p = 0,001. Na análise multivariada, a a'LAT (p = 0,001, a'SEP (p = 0,002, relação e'/a' LAT (p = 0,006, relação e'Mitral/ e'LAT (p = 0,014, SINF (p = 0,009 foram preditores de RC > 3A. Obtivemos um escore com sensibilidade de 88,2%, acurácia de 79,6%, e valor preditivo negativo de 92,9% para diagnosticar RC > 3A. O Doppler convencional (fluxo mitral e pulmonar venoso não foi relevante para predizer a RC > 3A. CONCLUSÃO: O estudo de IDT agregou informação diagnóstica para predizer RC > 3A quando comparado ao Doppler convencional. O modelo baseado em IDT pode ser tornar um método em potencial para detectar RC > 3A após TC.FUNDAMENTO: La biopsia endomiocárdica (BEM es el método gold standard para el diagnóstico de rechazo celular (RC después de transplante cardíaco (TC. OBJETIVO: Testear la hipótesis de que el examen de imagen con Doppler tisular (IDT puede detectar RC > 3A y agregar información diagnóstica, comparado al Doppler convencional. MÉTODOS: Cincuenta y cuatro pacientes con TC fueron sometidos a BEM y estudio ecocardiográfico a través de IDT en hasta 24 horas. Comparamos los pacientes con TC y RC > 3A con pacientes con TC y RC 3A en 39/129 (30,2% de las BEM. El mejor predictor aislado para el diagnóstico de RC fue la a'LAT, con sensibilidad de 76

  16. Doppler limited rotational transitions of OH and SH radicals measured by continuous-wave terahertz photomixing

    Science.gov (United States)

    Eliet, Sophie; Martin-Drumel, Marie-Aline; Guinet, Mickaël; Hindle, Francis; Mouret, Gaël; Bocquet, Robin; Cuisset, Arnaud

    2011-12-01

    A continuous-wave terahertz (CW-THz) source generated by photomixing has been employed to detect and quantify radicals produced in a cold plasma probing their spin-rotation transitions. Due to their dual interest for both atmospherists and astrophysicists, the hydroxyl OH and the mercapto SH radicals have been chosen. The photomixing technique which can access the largest range of THz frequencies of any known coherent source, allowed to resolve the Doppler-limited hyperfine transitions of OH in the 2.5 THz frequency region. Line profile analysis of the hyperfine components demonstrated that OH radicals have been detected in this region at a ppm level at a temperature close to 490 K. The hyperfine structure of SH has been resolved for the first time above 1 THz. Ten new frequency transitions have been measured in the 1.3-2.6 THz frequency range using the CW-THz synthesizer based on a frequency comb. With relative uncertainties better than 10 -7, the CW-THz frequencies measured in this study are now competitive with those measured by other instruments such as frequency multiplication chains or FT-FIR spectrometers and are now capable to improve the predictions of the complete high-resolution spectra of these radicals collected in the atmospheric and astrophysical spectroscopic databases. versioncorrigeeAC 2011-07-18 17:32 2011 Arnaud Cuisset.

  17. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Science.gov (United States)

    Goel, Sumit; Nagendrareddy, Suma Gundareddy; Raju, Manthena Srinivasa; Krishnojirao, Dayashankara Rao Jingade; Rastogi, Rajul; Mohan, Ravi Prakash Sasankoti; Gupta, Swati

    2011-01-01

    Aim: To evaluate the efficacy of ultrasonography (USG) with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas) of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas). There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions. PMID:22223940

  18. Ultrasonography with color Doppler and power Doppler in the diagnosis of periapical lesions

    Directory of Open Access Journals (Sweden)

    Sumit Goel

    2011-01-01

    Full Text Available Aim: To evaluate the efficacy of ultrasonography (USG with color Doppler and power Doppler applications over conventional radiography in the diagnosis of periapical lesions. Materials and Methods: Thirty patients having inflammatory periapical lesions of the maxillary or mandibular anterior teeth and requiring endodontic surgery were selected for inclusion in this study. All patients consented to participate in the study. We used conventional periapical radiographs as well as USG with color Doppler and power Doppler for the diagnosis of these lesions. Their diagnostic performances were compared against histopathologic examination. All data were compared and statistically analyzed. Results: USG examination with color Doppler and power Doppler identified 29 (19 cysts and 10 granulomas of 30 periapical lesions accurately, with a sensitivity of 100% for cysts and 90.91% for granulomas and a specificity of 90.91% for cysts and 100% for granulomas. In comparison, conventional intraoral radiography identified only 21 lesions (sensitivity of 78.9% for cysts and 45.4% for granulomas and specificity of 45.4% for cysts and 78.9% for granulomas. There was definite correlation between the echotexture of the lesions and the histopathological features except in one case. Conclusions: USG imaging with color Doppler and power Doppler is superior to conventional intraoral radiographic methods for diagnosing the nature of periapical lesions in the anterior jaws. This study reveals the potential of USG examination in the study of other jaw lesions.

  19. Echocardiography in the adult's congenital cardiopaties

    International Nuclear Information System (INIS)

    Escobar Q, Carlos I; Jaramillo U, Mario; Tenorio, Luis F; Molina V, Claudia; Saldarriaga A, Marcela; Arango, Angela M

    2003-01-01

    The number of adults with congenital heart disease is steadily increasing in the course of time. We ignore the prevalence and the most frequent diagnoses in our environment. A descriptive prospective study is presented. Between November 1 1999 and July 31 2001, 8871 Tran-thoracic and Tran-esophageal echocardiographies were performed in the Clinica Cardiovascular Santa Maria's echocardiography service. We found 143 congenital cardiopathies (1.6%) in 74 men and 69 women with a mean age of 37.7 +/- 18.4 years. the most frequent diagnoses were bicuspid aortic valve, atrial septal defect, ventricular septal defect, patent ductus arteriosus and Ebstein's anomaly. these findings agree with world wide data

  20. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Ali, M.; Abid, A.R.; Rehman, T.A.; Masood, A.; Sohail, S.

    2010-01-01

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By applying 2 X 2 table sensitivity was 77.7%, specificity was 80

  1. Estimation of left ventricular end diastolic pressure by tissue doppler imaging in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ali, M; Abid, A R; Rehman, T A; Masood, A; Sohail, S [Allama Iqbal Medical College/Jinnah Hospital, Lahore(Pakistan)

    2010-10-15

    Objective: To evaluate sensitivity and specificity of E / Ea > 10 for prediction of LVEDP > 15 mmHg in patients with coronary artery disease undergoing left heart catheterization. Materials and Methods: Sixty patients of acute transmural myocardial infarction at Jinnah Hospital Lahore were enrolled in study from December 2008 to December 2009. Patients with sinus rhythm were included in the study. Patients with valvular heart disease, complete right/left bundle branch block, Pacemaker dependence, Atrial fibrillation and Post mitral valve replacement were excluded. All patients were examined by performing trans thoracic Doppler echocardiography. The trans-mitral LV filling signal was traced manually and the following variables were obtained: peak early (E) and late (A) trans-mitral velocities, and E/A ratio. Tissue - Doppler derived indices were recorded at the lateral mitral annulus. These indices included systolic velocities (S'), early diastolic (Ea) velocities and late diastolic (Aa) velocities. Finally, the dimensionless index of E/Ea was calculated. All were averaged from at least three beats. Cardiac catheterization was performed via trans-femoral / trasradial route using six French (6F) sheaths. Left ventricular diastolic pressure was directly measured by fluid filled pigtail catheter attached to a pressure transducer. Results: Mean age of the study population was 56.8 +- 12.7 years. There were 47 (78.3%) males and 13 (21.7%) females. Diabetes mellitus was present in 12(20%), hypertension in 32 (53.3%), smoking in 35 (58.3%), dyslipidemia in 24 (40%). Anterior wall myocardial infarction occurred in 44 (73.3%) and inferior wall MI in 16 (26.7%). Grade I diastolic dysfunction was present in 22 (36.7%), Grade II in 31 (51.7%) and Grade III in 7 (11.7%) patients. E/E < 10 was observed in 31 (51.7%), 11 - 15 in 20 (33.3%) and > 15 in 9 (15%). Overall 21 patients were true positive, 6 were false positive, 25 were true negative and 8 were false negative. By

  2. Comparative study between MRI and echocardiography in noncompaction of ventricular myocardium

    International Nuclear Information System (INIS)

    Sun Ziyan; Xia Liming; Wang Chengyuan; Rao Jingjing; Shenyu Weihui

    2007-01-01

    Objective: To investigate the MRI and echocardiography manifestations of noncompaction of ventricular myocardium(NVM) and assess the role of MR1 in the diagnosis of NVM by comparing it with echocardiography. Methods: Fourteen cases of NVM diagnosed by echocardiography were examined with MRI, including scanning of black-blood sequences, double inversion recovery fast spin echo (DIBFSE) and triple inversion recovery fast spin echo (TIRFSE), and white blood sequence: fast imaging employ steady state acquisition (FIESTA). Scanning plane includes short axis view, four-chamber view and long axis view. Results: Both MRI and echocardiography displayed involvement of left ventricles in thirteen cases and involvement of double ventricles in one case. Apexes of heart and the intermedius are commonly affected. MRI showed 54 segments and echocardiography showed 53 segments affected, and there is no significant difference between the capability of MRI and echocardiography (P=1,000). The affected myocardium consisted of two layers: subendocardial noncompacted myocardium and epicardial compacted myocardium, and the ratio measurement of N/C by MRI was 3.37±0.89 and it was 3.19±0.82 by echocardiography. Noncompacted myocardium was characterized by prominent and excessive myocardial trabeculations and deep intratrabecular recesses, in which the blood flow was communicated with the ventricle. One case was complicated with ventricular aneurysm, and coronary arteriography was performed with unremarkable findings. One case underwent heart transplantation because of progressive heart failure, Gross findings demonstrated prominent muscular' trabeculations with deep intratrabecular recesses, which coincided well with MRI findings. Conclusion: The MRI manifestation of NVM is characteristic, and MRI with multiple series and planes is helpful in the diagnose of NVM. Compared with echocardiography, MRI could display the pathological cardiac muscle more clearly, because of its high soft

  3. Evidence of abnormal left ventricular function in patients with thalassaemia major: an echocardiography based study

    International Nuclear Information System (INIS)

    Sohail, M.; Hyder, S.N.

    2009-01-01

    Thalassaemia represent one of the most common single gene disorder causing a major public health problem in Pakistan. Nearly 100,000 people are born worldwide with this severe blood disorder every year. Over the last 3 decades, the development of regular transfusion therapy and iron chelation has dramatically improved the quality of life and transformed thalassaemia from a rapidly fatal disease to a chronic disease compatible with prolonged survival. Objective of this observational cross sectional study was to determine the effects of chronic anaemia and transfusional iron overload on the left ventricular function using Doppler echocardiography. This study was conducted in the Department of Paediatric Cardiology, The Children's Hospital and Institute of Child Health, Lahore, Pakistan from first April 2006 to September 30, 2007. The study comprised of 50 consecutive cases of beta-Thalassaemia major and 30 controls with normal haemoglobin and electrophoresis pattern. beta- Thalassaemia major patients were diagnosed on the basis of haemoglobin electrophoresis. Patients with any congenital or acquired heart disease, concurrent infective disorder and with history of cardiac surgery were excluded from the study. 2-D, M-mode and Doppler echocardiography was performed in all the study cases and controls. Statistical comparison of study cases and controls was conducted by using unpaired t-test. The age of the patients ranged from 2 years to 25 years with mean age of 9.65 years. Males were 34 (68%) and females were 16 (32%). None of the study cases was on regular chelation programme while 31 (62%) patients were on irregular chelation with single dose of intravenous desferrioxamine only at the time of blood transfusion. 19 (38%) of the patients had LV dysfunction in the form of isolated systolic dysfunction in 2 (4%), isolated diastolic dysfunction in 15 (30%) while global dysfunction in 2 (4%) of the patients. Left ventricular dimensions, stroke volume and E/A ratio were

  4. Speckle tracking echocardiography in acute lupus myocarditis: comparison to conventional echocardiography

    Directory of Open Access Journals (Sweden)

    Riëtte Du Toit

    2017-07-01

    Full Text Available Aims: Lupus myocarditis occurs in 5–10% of patients with systemic lupus erythematosus (SLE. No single feature is diagnostic of lupus myocarditis. Speckle tracking echocardiography (STE can detect subclinical left ventricular dysfunction in SLE patients, with limited research on its utility in clinical lupus myocarditis. We report on STE in comparison to conventional echocardiography in patients with clinical lupus myocarditis. Methods and results: A retrospective study was done at a tertiary referral hospital in South Africa. SLE patients with lupus myocarditis were included and compared to healthy controls. Echocardiographic images were reanalyzed, including global longitudinal strain through STE. A poor echocardiographic outcome was defined as final left ventricular ejection fraction (LVEF <40%. 28 SLE patients fulfilled the criteria. Global longitudinal strain correlated with global (LVEF: r = −0.808; P = 0.001 and regional (wall motion score: r = 0.715; P < 0.001 function. In patients presenting with a LVEF ≥50%, global longitudinal strain (P = 0.023, wall motion score (P = 0.005 and diastolic function (P = 0.004 were significantly impaired vs controls. Following treatment, LVEF (35–47% (P = 0.023 and wall motion score (1.88–1.5 (P = 0.017 improved but not global longitudinal strain. Initial LVEF (34%; P = 0.046 and global longitudinal strain (−9.5%; P = 0.095 were lower in patients with a final LVEF <40%. Conclusions: This is the first known report on STE in a series of patients with clinical lupus myocarditis. Global longitudinal strain correlated with regional and global left ventricular function. Global longitudinal strain, wall motion score and diastolic parameters may be more sensitive markers of lupus myocarditis in patients presenting with a preserved LVEF ≥50%. A poor initial LVEF and global longitudinal strain were associated with a persistent LVEF <40%. Echocardiography is a non-invasive tool with diagnostic and

  5. Preliminary reference values for electrocardiography, echocardiography and myocardial morphometry in the European brown hare (Lepus europaeus

    Directory of Open Access Journals (Sweden)

    Slawuta Piotr

    2009-01-01

    Full Text Available Abstract The study aimed at defining reference values for electrocardiographic (ECG and echocardiographic parameters as well as macroscopic dimensions of the heart and microscopic dimensions of cardiomyocytes in the European brown hare. The studies were conducted on 30 adult, clinically healthy hares of either sex caught in Poland. ECG and echocardiography were performed supravitally on anaesthetized hares. After euthanasia, gross and microscopic myocardial and cardiomyocyte dimensions were determined. Heart rate amounted to 140 ± 37.5 beats/min, the leading rhythm involved the sinus rhythm. P wave time was 26 ± 5 ms, PQ time was 80 ms, QRS time was 29 ± 3.5 ms, and ST was 97.5 ± 7 ms. Echocardiography determined a left ventricular wall end-diastolic diameter of 8.6 ± 2.0 mm and an intraventricular septum end-diastolic diameter of 5.75 ± 1.0 mm. The thickness of the interventricular septum corresponded to that of the free wall of the left ventricle, a finding consistent with physiological hypertrophy. Preliminary reference values were established for echocardiography. The findings were similar to those obtained at necropsy. The ECG and echocardiographic studies represent the first supravital examination of cardiac function in the hare. The obtained results illustrate adaptation of hare's myocardium to its mode of life. The cardiac findings resemble the athlete's heart syndrome described in humans. The findings may prove useful in further studies on the physiology of the cardio-vascular system in the hare.

  6. Comparison of power Doppler and color Doppler ultrasonography in the detection of intrasticular blood flow of normal infants

    International Nuclear Information System (INIS)

    Shin, Sung Ran; Lee, Ho Kyoung; Lee, Won Gyun; Youk, Dong Joon; Rho, Taek Soo; Lee, Min Jin; Lee, Sang Chun

    1999-01-01

    To compare color Doppler ultrasonography (US) and power Doppler US in the detection of intratesticular blood flow in normal infants and to asses the symmetry of blood flow. Testicular blood flow was assessed prospectively in 100 testes of 50 infants with both power and color Doppler US. We compared the power Doppler with color Doppler to detect intratesticular blood. When the flow was detected, intratesticular blood flow was graded as follows: grade 1: single intratesticular Doppler signal ; grade 2: multiple intratesticular Doppler signals. The symmetry of intratesticular flow was assessed by using the same method. Intratesticular flow was detected in 72 (72%) and 68 (68%) testes on power and color Doppler US, respectively. In 76 testes (76%), intratesticular flow was detected in either one or both techniques. On power Doppler US, grade 1 was seen in 40 tests and grade 2 in 32 testes. On color Doppler US, grade 1 was noted in 52 testes and grade 2 in 16 testes. Testicular blood flow was symmetric on both power and color Doppler US in each patient. There was no difference between power Doppler and color Doppler ultrasonography in detecting intratesticular blood flow in normal infants.

  7. Changes in cardiac function and structure in newly diagnosed Graves' disease. A conventional and 2D-speckle tracking echocardiography study.

    Science.gov (United States)

    Aroditis, K; Pikilidou, M; Vourvouri, E; Hadjistavri, L; Zebekakis, P; Yovos, J; Efthimiadis, G; Karvounis, H

    2017-02-01

    Overproduction of thyroid hormones leads to structural as well as functional cardiac changes. Conventional echocardiography but also recently developed sophisticated two-dimensional echocardiography speckle (2D-STE) tracking allow elaborate evaluation of these changes. Our purpose was to investigate the effects of thyroid hormones overproduction on the heart in patients with Graves' disease and changes that occur after 6 months thyrostatic therapy. We conducted a prospective, case-control study of 6 months duration. Full echocardiographic assessment at diagnosis and after 6 months of thyrostatic therapy were performed in 44 patients with Graves' disease, aged 37.6 ± 9.1 years. Additionally, 43 euthyroid controls were studied for the same time period. Left ventricular end diastolic diameter (LVEDD) and left ventricular end systolic diameter (LVESD) were higher in the patient group while triscupid annular plane systolic excursion (TAPSE) was lower in the patient group. Moreover, left ventricular (LV) mass index and left atrium (LA) volume index were higher in the Graves' disease group. Diastolic impairment as assessed with conventional echocardiography including tissue Doppler was present in the patient group (E/A ratio 0.87 ± 0.10,). 2D-STE analysis, revealed an increase in the strain rate at the isovolumic relaxation time (SRIVRT, 0.310 ± 0.07 patients versus 0.298 ± 0.09 s -1 controls). Improvement in diastolic and right systolic function as well as in left ventricular structural parameters was observed after restoration of euthyroidism (E/A ratio from 0.87 ± 0.10 versus 0.9 ± 0.08, p < 0.05). Patients with newly diagnosed Graves' showed an improvement in diastolic function, right systolic function and structural parameters after 6 months of thyrostatic treatment.

  8. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H.; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...... vectors. This review briefly introduces the principles behind colour Doppler imaging and describes some clinical applications. It then describes the basic components of conventional colour Doppler systems and the methods used to derive velocity information from the ultrasound signal. Next, a number of new...

  9. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    DEFF Research Database (Denmark)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel

    2018-01-01

    ) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. RESULTS: 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D...... echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different...... between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r

  10. Exercise stress echocardiography in patients with valvular heart disease.

    Science.gov (United States)

    Sharma, Vishal; Newby, David E; Stewart, Ralph A H; Lee, Mildred; Gabriel, Ruvin; Van Pelt, Niels; Kerr, Andrew J

    2015-09-01

    Stress echocardiography is recommended for the assessment of asymptomatic patients with severe valvular heart disease (VHD) when there is discrepancy between symptoms and resting markers of severity. The aim of this study is to determine the prognostic value of exercise stress echocardiography in patients with common valve lesions. One hundred and fifteen patients with VHD (aortic stenosis (n=28); aortic regurgitation (n=35); mitral regurgitation, (n=26); mitral stenosis (n=26)), and age- and sex-matched controls (n=39) with normal ejection fraction underwent exercise stress echocardiography. The primary endpoint was a composite of death or hospitalization for heart failure. Asymptomatic VHD patients had lower exercise capacity than controls and 37% of patients achieved 60 mmHg) was associated with an increased risk of death or hospital admission (14% vs 1%, P<0.0001). The assessment of contractile reserve did not offer additional predictive value. In conclusion, an abnormal stress echocardiogram is associated with death and hospitalization with heart failure at 2 years. Stress echocardiography should be considered as part of the routine follow-up of all asymptomatic patients with VHD.

  11. Simulation for transthoracic echocardiography of aortic valve

    Science.gov (United States)

    Nanda, Navin C.; Kapur, K. K.; Kapoor, Poonam Malhotra

    2016-01-01

    Simulation allows interactive transthoracic echocardiography (TTE) learning using a virtual three-dimensional model of the heart and may aid in the acquisition of the cognitive and technical skills needed to perform TTE. The ability to link probe manipulation, cardiac anatomy, and echocardiographic images using a simulator has been shown to be an effective model for training anesthesiology residents in transesophageal echocardiography. A proposed alternative to real-time reality patient-based learning is simulation-based training that allows anesthesiologists to learn complex concepts and procedures, especially for specific structures such as aortic valve. PMID:27397455

  12. Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

    Science.gov (United States)

    Stoebe, Stephan; Metze, Michael; Jurisch, Daniel; Tayal, Bhupendar; Solty, Kilian; Laufs, Ulrich; Pfeiffer, Dietrich; Hagendorff, Andreas

    2018-01-01

    Purpose The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. Methods Left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-quantitative parameters were assessed by 2D echocardiography. Results 22 (40%) patients had mild, 25 (46%) moderate and 8 (14%) severe AR. The quantitative volumetric approach was feasible using 2D, 3D echocardiography and cMRI, whereas the feasibility of semi-quantitative parameters varied considerably. LV volume (LVEDV, LVESV, SVtot) analyses showed good correlations between the different imaging modalities, although significantly increased LV volumes were assessed by cMRI. RVol was significantly different between 2D/3D echocardiography and 2D echocardiography/cMRI but was not significantly different between 3D echocardiography/cMRI. RF was not statistically different between 2D echocardiography/cMRI and 3D echocardiography/cMRI showing poor correlations (r echocardiography and 2D echocardiography/cMRI and good agreement was observed between 3D echocardiography/cMRI. Conclusion Semi-quantitative parameters are difficult to determine by 2D echocardiography in clinical routine. The quantitative volumetric RF assessment seems to be feasible and can be discussed as an alternative approach in chronic AR. However, RVol and RF did not correlate well between the different imaging modalities. The best agreement for grading of AR severity by RF was observed between 3D echocardiography and cMRI. LV volumes can be verified by different approaches and different imaging modalities. PMID:29519957

  13. New phase method of measuring particle size with laser Doppler radar

    Science.gov (United States)

    Zemlianskii, Vladimir M.

    1996-06-01

    A vast field of non-contact metrology, vibrometry, dynamics and microdynamics problems solved on the basis of laser Doppler method resulted in the development of great variety of laser Doppler radar (LDR). In coherent LDR few beams with various polarization are generally adopted, that are directed at the zone of measurement, through which the probing air stream moves. Studies of various coherent LDR demonstrated that polarization-phase effects of scattering can in some cases considerably effect on the signal-to-noise ratio of the Doppler signal. On the other side using phase effects can simultaneous measurement of size and velocity of spherical particles. New possibilities for improving the accuracy of measuring spherical particles' sizes come to light when application is made in coherent LDR of two waves- probing and one out of the types of symmetrical reception of scattered radiation, during which phase-conjugate signals are formed. The theoretical analysis on the basis of the scattering theory showed, that in symmetrical reception of scattered radiation with respect to the planes OXZ and OYZ output signal of the photoreceiver contains two high- frequency signal components, which in relation to parameters of the probing and size, can either be in phase or antiphase. Results of numerical modeling are presented: amplitude of high frequency signal, coefficient of phase and polarization matching of mixed waves, the depths of photocurrent modulation and also signal's phase in relation to the angle between the probing beams. Phase method of determining particle's sizes based on the use of two wavelengths probing and symmetrical reception of scattered radiation in which conditions for the formation of phase conjugated high-frequency signals are satisfied is presented.

  14. Digital echocardiography and telemedicine applications in pediatric cardiology.

    Science.gov (United States)

    Sable, Craig

    2002-01-01

    Digital echocardiography offers several advantages over videotape, including easy review, comparison, storage, postprocessing, and sharing of studies, quantitative analysis, and superior resolution. Newer echocardiography systems can write digital data to computer hardware, whereas older systems require digitization of analog data. Clinical and digital data compression is required to reduce study size. Clinical compression has been validated in several adult studies and one pediatric study. JPEG and MPEG digital compression ratios of 26:1 and 200:1, respectively, approximate S-videotape quality. JPEG is the DICOM 3.0 standard and is ideal for short loops, serial comparisons, and quantitative analysis. MPEG (the motion picture standard) lends itself to digitization of video streams and may be more attractive to pediatric cardiologists. Options for data storage and transfer range from limited local review to multiple offline review stations linked by a wide-area network. Telemedicine expands the capabilities of digital echocardiography in a "store and forward" or "real-time" format. Real-time neonatal telecardiology is accurate, impacts patient care, is cost-effective, and does not increase utilization. Cost, increased reliance on sonographers' skills, lack of accepted standards, and legal, licensure, and billing issues are obstacles to widespread acceptance of digital echocardiography and telemedicine.

  15. Evaluation of prosthetic heart valves by transesophageal echocardiography: problems, pitfalls, and timing of echocardiography

    NARCIS (Netherlands)

    van den Brink, Renee B. A.

    2006-01-01

    Transesophageal echocardiography (TEE) is especially suitable for examination of prosthetic valves because of the proximity of the esophagus to the heart and absence of interference with lungs and ribs. This article reviews normal and abnormal morphologic characteristics of prosthetic valves such as

  16. Recommendations for fetal echocardiography in twin pregnancy in 2016

    Directory of Open Access Journals (Sweden)

    Leszczyńska Katarzyna

    2016-01-01

    Full Text Available Progress in the fields of fetal cardiology and fetal surgery have been seen not only in singleton pregnancies but also in multiple pregnancies. Proper interpretation of prenatal echocardiography is critical to clinical decision making, family counseling and perinatal management for obstetricians, maternal fetal medicine specialists, neonatologists and pediatric cardiologists. Fetal echocardiography is one of the most challenging and time-consuming prenatal examinations to perform, especially in multiple gestations. Performing just the basic fetal exam in twin gestations may take an hour or more. Thus, it is not practical to perform this exam in all cases of multiple gestations. Therefore our review and recommendations are related to fetal echocardiography in twin gestation.

  17. Cardiodiagnostic imaging. MRT, CT, echocardiography and other methods

    International Nuclear Information System (INIS)

    Erbel, R.; Kreitner, K.F.; Barkhausen, J.; Thelen, M.

    2007-01-01

    The book presents a differentiated approach to cardiac imaging. The focus is n cardio-MR/-CT and echocardiography. These are highly complex methods involving new equipment, new protocols and indications. The techniques are new and difficult to learn for everybody concerned. MR, CT and echocardiography must always be viewed in the context of other diagnostic methods. The interdisciplinary approach of the book addresses both radiologists and cardiologists and relies on the vast experience of the authors. The book offers more than 500 large high-quality reference images reflecting the latest state of the art. It has amethodological section in which the current methods are described (X-ray, echocardiography, nuclear medicine, angiography, CT, MRT etc.) along with their advantages and shortcomings, and a clinical section in which the main indications are described in the common standardized way (anatomy, clinical picture, interpretation, differential diagnosis). (orig.)

  18. Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography

    Directory of Open Access Journals (Sweden)

    Minardi Giovanni

    2006-09-01

    Full Text Available Abstract Background The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm in relatively aged patients at mean 24 months follow-up. Methods and results The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 ± 7.3 years. All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 micrg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min. The following parameters were evaluated at rest and/or under DSE: heart rate (HR, ejection fraction (EF, cardiac output (CO, peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG, effective orifice area (EOA, indexed EOA (EOAi, left ventricular mass (LVM, indexed LVM (LVMi, Velocity Time Integral at left ventricular outflow tract (VTI LVOT and transvalvular (Aortic VTI, Doppler velocity index (DVI. At rest MxPG and MnPG were 29.2 ± 7.1 and 16.6 ± 5.8mmHg, respectively; EOA and EOAi resulted 1.14 ± 0.3 cm2 and 0.76 ± 0.2 cm2/m2; DVI was normal (0.50 ± 0.1. At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 ± 43g and 157.4 ± 27.7g/m2 to 191 ± 23.8g and 114.5 ± 10.6g/m2, respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 ± 2 1.9mmHg, MnPG (up to 43.2 ± 12.7mmHg. EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 ± 0.4 cm2, 0.75 ± 0.3cm2/m2 and 0.48 ± 0.1 respectively. Two patients developed significant intraventricular gradients. Conclusion These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic

  19. Signal-averaged P wave duration and the dimensions of the atria

    DEFF Research Database (Denmark)

    Dixen, Ulrik; Joens, Christian; Rasmussen, Bo V

    2004-01-01

    Delay of atrial electrical conduction measured as prolonged signal-averaged P wave duration (SAPWD) could be due to atrial enlargement. Here, we aimed to compare different atrial size parameters obtained from echocardiography with the SAPWD measured with a signal-averaged electrocardiogram (SAECG)....

  20. Gallblader varices in children with portal cavernoma: duplex-Doppler and color Doppler ultrasound studies

    International Nuclear Information System (INIS)

    Muro, D.; Sanguesa, C.; Lopez, A.

    1998-01-01

    To determine the prevalence of varices in the gallbladder wall, observed by duplex-Doppler and color Doppler ultrasound, in children with cavernoma of the portal vein. Nineteen patients with portal hypertension were studied prospectively by duplex-Doppler and color Doppler ultrasound: 12 of the patients had developed a cavernoma of the portal vein. The presence of peri vesicular varices was assessed in the group of patients with portal cavernoma. Duplex-Doppler and color Doppler ultrasound disclosed the presence of varices in gallbladder wall in nine of the 12 patients (75%). The varices appeared as anechoic and serpiginous areas, and Doppler ultrasound revealed slowed venous flow. However, the three patients in whom gallbldder varices were not detected presented collateral gastric ciculation and spontaneous splenorenal shunt. Gallbladder varices are common in children with portal vein cavernoma; they present hepatopetal flow. Their developments is not related to the size of the portal cavernoma, the presence of spontaneous portosystemic shunts, or endoscopic obliteration of gastric and esophageal varices. The detection of gallbladder varices in patients with portal hypertension who are to undergo biliary surgery is highly important for the surgeon, helping to avoid perioperative complications. (Author) 15 refs

  1. Parametric Investigation of Laser Doppler Microphones

    Science.gov (United States)

    Daoud, M.; Naguib, A.

    2002-11-01

    The concept of a Laser Doppler Microphone (LDM) is based on utilizing the Doppler frequency shift of a focused laser beam to measure the unsteady velocity of the center point of a flexible polymer diaphragm that is mounted on top of a hole and subjected to the unsteady pressure. Time integration of the velocity signal yields a time series of the diaphragm displacement, which can be converted to pressure from knowledge of the sensor's deflection sensitivity. In our APS/DFD presentation last year, the stringent frequency resolution requirement of these new sensors and methods to meet this requirement were discussed. Here, the dependence of the sensor characteristics (sensitivity, bandwidth, and noise floor) on various significant parameters is investigated in detail by calibrating the sensor in a plane wave tube in the frequency range of 50 - 5000 Hz. Parameters investigated include sensor diaphragm material and thickness, sensor size, damping of the diaphragm motion and laser beam spot size. The results shed light on the operating limits of the new sensor and demonstrate its ability to conduct high-spatial-resolution measurements in typical high-Reynolds-number test facilities. Moreover, calibrated LDM sensors were used to conduct measurements in a separating/reattaching flow and the results are compared to classical electret-type microphones with a similar sensing diameter.

  2. P wave dispersion and maximum P wave duration are independently associated with rapid renal function decline.

    Science.gov (United States)

    Su, Ho-Ming; Tsai, Wei-Chung; Lin, Tsung-Hsien; Hsu, Po-Chao; Lee, Wen-Hsien; Lin, Ming-Yen; Chen, Szu-Chia; Lee, Chee-Siong; Voon, Wen-Chol; Lai, Wen-Ter; Sheu, Sheng-Hsiung

    2012-01-01

    The P wave parameters measured by 12-lead electrocardiogram (ECG) are commonly used as noninvasive tools to assess for left atrial enlargement. There are limited studies to evaluate whether P wave parameters are independently associated with decline in renal function. Accordingly, the aim of this study is to assess whether P wave parameters are independently associated with progression to renal end point of ≥25% decline in estimated glomerular filtration rate (eGFR). This longitudinal study included 166 patients. The renal end point was defined as ≥25% decline in eGFR. We measured two ECG P wave parameters corrected by heart rate, i.e. corrected P wave dispersion (PWdisperC) and corrected P wave maximum duration (PWdurMaxC). Heart function and structure were measured from echocardiography. Clinical data, P wave parameters, and echocardiographic measurements were compared and analyzed. Forty-three patients (25.9%) reached renal end point. Kaplan-Meier curves for renal end point-free survival showed PWdisperC > median (63.0 ms) (log-rank P = 0.004) and PWdurMaxC > median (117.9 ms) (log-rank Pfunction decline.

  3. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  4. Doppler optical coherence microscopy and tomography applied to inner ear mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Page, Scott; Freeman, Dennis M. [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States); Ghaffari, Roozbeh [Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, Massachusetts (United States)

    2015-12-31

    While it is clear that cochlear traveling waves underlie the extraordinary sensitivity, frequency selectivity, and dynamic range of mammalian hearing, the underlying micromechanical mechanisms remain unresolved. Recent advances in low coherence measurement techniques show promise over traditional laser Doppler vibrometry and video microscopy, which are limited by low reflectivities of cochlear structures and restricted optical access. Doppler optical coherence tomography (DOCT) and Doppler optical coherence microscopy (DOCM) both utilize a broadband source to limit constructive interference of scattered light to a small axial depth called a coherence gate. The coherence gate can be swept axially to image and measure sub-nanometer motions of cochlear structures throughout the cochlear partition. The coherence gate of DOCT is generally narrower than the confocal gate of the focusing optics, enabling increased axial resolution (typically 15 μm) within optical sections of the cochlear partition. DOCM, frequently implemented in the time domain, centers the coherence gate on the focal plane, achieving enhanced lateral and axial resolution when the confocal gate is narrower than the coherence gate. We compare these two complementary systems and demonstrate their utility in studying cellular and micromechanical mechanisms involved in mammalian hearing.

  5. On-Orbit Prospective Echocardiography on International Space Station Crew

    Science.gov (United States)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Martin, David S.; Garcia, Kathleen M.; Melton, Shannon L.; Feiveson, Alan; Dulchavsky, Scott A.

    2010-01-01

    Introduction A prospective trial of echocardiography was conducted on of six crewmembers onboard the International Space Station. The main objective was to determine the efficacy of remotely guided tele-echocardiography, including just-in-time e-training methods and determine what "space normal" echocardiographic data is. Methods Each crewmember operator (n=6) had 2-hour preflight training. Baseline echocardiographic data were collected 55 to 167days preflight. Similar equipment was used in each 60-minute in-flight session (mean microgravity exposure - 114 days (34 -- 190)). On Orbit ultrasound operators used an e-learning system within 24h of these sessions. Expert assistance was provided using ultrasound video downlink and two-way voice. Testing was repeated 5 to 16 days after landing. Separate ANOVA was used on each echocardiographic variable (n=33). Within each ANOVA, three tests were made: a) effect of mission phase (preflight, in-flight, post flight); b) effect of echo technician (two technicians independently analyzed the data); c) interaction between mission phase and technician. Results Nine rejections of the null hypothesis (mission phase or technician or both had no effect) were discovered and considered for follow up. Of these, six rejections were for significant technician effects, not as a result of space flight. Three rejections of the null hypothesis (Aortic Valve time velocity integral, Mitral E wave Velocity and heart rate) were attributable to space flight, however determined not to be clinically significant. No rejections were due to the interaction between technician and space flight. Conclusion No consistent clinically significant effects of long-duration space flight were seen in echocardiographic variables of the given group of subjects.

  6. Directional nonlinear guided wave mixing: Case study of counter-propagating shear horizontal waves

    Science.gov (United States)

    Hasanian, Mostafa; Lissenden, Cliff J.

    2018-04-01

    While much nonlinear ultrasonics research has been conducted on higher harmonic generation, wave mixing provides the potential for sensitive measurements of incipient damage unencumbered by instrumentation nonlinearity. Studies of nonlinear ultrasonic wave mixing, both collinear and noncollinear, for bulk waves have shown the robust capability of wave mixing for early damage detection. One merit of bulk wave mixing lies in their non-dispersive nature, but guided waves enable inspection of otherwise inaccessible material and a variety of mixing options. Co-directional guided wave mixing was studied previously, but arbitrary direction guided wave mixing has not been addressed until recently. Wave vector analysis is applied to study variable mixing angles to find wave mode triplets (two primary waves and a secondary wave) resulting in the phase matching condition. As a case study, counter-propagating Shear Horizontal (SH) guided wave mixing is analyzed. SH wave interactions generate a secondary Lamb wave mode that is readily receivable. Reception of the secondary Lamb wave mode is compared for an angle beam transducer, an air coupled transducer, and a laser Doppler vibrometer (LDV). Results from the angle beam and air coupled transducers are quite consistent, while the LDV measurement is plagued by variability issues.

  7. Archeological Echocardiography: Digitization and Speckle-Tracking Analysis of Archival Echocardiograms in the HyperGEN Study

    Science.gov (United States)

    Aguilar, Frank G.; Selvaraj, Senthil; Martinez, Eva E.; Katz, Daniel H.; Beussink, Lauren; Kim, Kwang-Youn A.; Ping, Jie; Rasmussen-Torvik, Laura; Goyal, Amita; Sha, Jin; Irvin, Marguerite R.; Arnett, Donna K.; Shah, Sanjiv J.

    2015-01-01

    Background Several large epidemiologic studies and clinical trials have included echocardiography, but images were stored in analog format and these studies predated tissue Doppler imaging (TDI) and speckle-tracking echocardiography (STE). We hypothesized that digitization of analog echocardiograms, with subsequent quantification of cardiac mechanics using STE, is feasible, reproducible, accurate, and produces clinically valid results. Methods In the NHLBI HyperGEN study (N=2234), archived analog echocardiograms were digitized and subsequently analyzed using STE to obtain tissue velocities/strain. Echocardiograms were assigned quality scores and inter/intraobserver agreement was calculated. Accuracy was evaluated in (1) a separate second study (N=50) comparing prospective digital strain vs. post-hoc analog-to-digital strain; and (2) in a third study (N=95) comparing prospectively-obtained TDI e′ velocities with post-hoc STE e′ velocities. Finally, we replicated previously known associations between tissue velocities/strain, conventional echocardiographic measurements, and clinical data. Results Of the 2234 HyperGEN echocardiograms, 2150 (96.2%) underwent successful digitization and STE analysis. Inter/intraobserver agreement was high for all STE parameters, especially longitudinal strain (LS). In accuracy studies, LS performed best when comparing post-hoc STE to prospective digital STE for strain analysis. STE-derived e′ velocities correlated with, but systematically underestimated, TDI e′ velocity. Several known associations between clinical variables and cardiac mechanics were replicated in HyperGEN. We also found a novel independent inverse association between fasting glucose and LS (adjusted β =−2.4 [95% CI −3.6,−1.2]% per 1-SD increase in fasting glucose; Pechocardiography, the digitization and speckle-tracking analysis of archival echocardiograms, is feasible and generates parameters of cardiac mechanics similar to contemporary studies. PMID

  8. Prognostic value of systolic mitral annular velocity measured with Doppler tissue imaging in patients with chronic heart failure caused by left ventricular systolic dysfunction

    Science.gov (United States)

    Nikitin, N P; Loh, P H; de Silva, R; Ghosh, J; Khaleva, O Y; Goode, K; Rigby, A S; Alamgir, F; Clark, A L; Cleland, J G F

    2006-01-01

    Objective To assess the prognostic value of various conventional and novel echocardiographic indices in patients with chronic heart failure (CHF) caused by left ventricular (LV) systolic dysfunction. Methods 185 patients with a mean (SD) age of 67 (11) years with CHF and LV ejection fraction < 45% despite optimal pharmacological treatment were prospectively enrolled. The patients underwent two dimensional echocardiography with tissue harmonic imaging to assess global LV systolic function and obtain volumetric data. Transmitral flow was assessed with conventional pulse wave Doppler. Systolic (Sm), early, and late diastolic mitral annular velocities were measured with the use of colour coded Doppler tissue imaging. Results During a median follow up of 32 months (range 24–38 months in survivors), 34 patients died and one underwent heart transplantation. Sm velocity (hazard ratio (HR) 0.648, 95% confidence interval (CI) 0.463 to 0.907, p  =  0.011), diastolic arterial pressure (HR 0.965, 95% CI 0.938 to 0.993, p  =  0.015), serum creatinine (HR 1.006, 95% CI 1.001 to 1.011, p  =  0.023), LV ejection fraction (HR 0.945, 95% CI 0.899 to 0.992, p  =  0.024), age (HR 1.035, 95% CI 1.000 to 1.071, p  =  0.052), LV end systolic volume index (HR 1.009, 95% CI 0.999 to 1.019, p  =  0.067), and restrictive pattern of transmitral flow (HR 0.543, 95% CI 0.278 to 1.061, p  =  0.074) predicted the outcome of death or transplantation on univariate analysis. On multivariate analysis, only Sm velocity (HR 0.648, 95% CI 0.460 to 0.912, p  =  0.013) and diastolic arterial pressure (HR 0.966, 95% CI 0.938 to 0.994, p  =  0.016) emerged as independent predictors of outcome. Conclusions In patients with CHF and LV systolic dysfunction despite optimal pharmacological treatment, the strongest independent echocardiographic predictor of prognosis was Sm velocity measured with quantitative colour coded Doppler tissue

  9. Development of left ventricular longitudinal speckle tracking echocardiography in very low birth weight infants with and without bronchopulmonary dysplasia during the neonatal period.

    Directory of Open Access Journals (Sweden)

    Christoph Czernik

    Full Text Available OBJECTIVES: In preterm infants, postnatal myocardial adaptation may be complicated by bronchopulmonary dysplasia (BPD. We aimed to describe the development of left ventricular function by serial 2D, Doppler, and speckle tracking echocardiography (2D-STE in infants with and without BPD during the neonatal period and compare these to anthropometric and conventional hemodynamic parameters. STUDY DESIGN: Prospective echocardiography on day of life (DOL 1, 7, 14, and 28 in 119 preterm infants 10% were seen for the apical segment. While anthropometric parameters show rapid development during the first 4 weeks of life, the speckle tracking parameters did not differ statistically significantly during the neonatal period. Infants with and without BPD differed significantly (p<0.001 in the development of anthropometric parameters, conventional hemodynamic parameters except for heart rate, and 2D-STE parameters: global longitudinal systolic strain rate (GLSSR and longitudinal systolic strain for the mid left wall (LSSR. The largest differences were seen at DOL 1 and 7 in GLSSR (p<0.001 and in LSSR (p<0.01. CONCLUSIONS: Reproducible 2D-STE measurements are possible in preterm infants <1500 g. Cardiac deformation reveals early (DOL 1 and 7 ventricular changes (GLSSR and LSSR in very low birth weight infants who develop BPD.

  10. Avaliação dos tumores hepáticos ao Doppler Doppler evaluation of liver tumors

    Directory of Open Access Journals (Sweden)

    Márcio Martins Machado

    2004-10-01

    Full Text Available Os avanços recentes na ultra-sonografia têm ampliado a possibilidade de detecção de tumores hepáticos. Isto tem auxiliado na perspectiva de melhora do prognóstico destes pacientes, à medida que novas técnicas terapêuticas têm surgido. Neste artigo os autores relatam achados ao Doppler que podem auxiliar na identificação e caracterização dos tumores hepáticos, avaliando dados do Doppler colorido, pulsado e do Doppler de amplitude ("power Doppler". Fazem, também, referência a novas modalidades de imagem, como o uso da harmônica.Recent advances in ultrasound have optimized the detection of liver tumors and helped to improve the prognosis of patients with this condition as newly developed and improved therapeutic modalities have been established. The authors review important Doppler findings which may help in the identification and characterization of some hepatic tumors through the evaluation of color Doppler, pulsed Doppler and power Doppler features. New imaging methods such as the use of harmonics imaging are also reviewed.

  11. Solitary waves of surface plasmon polariton via phase shifts under Doppler broadening and Kerr nonlinearity

    Science.gov (United States)

    Ahmad, S.; Ahmad, A.; Bacha, B. A.; Khan, A. A.; Abdul Jabar, M. S.

    2017-12-01

    Surface Plasmon Polaritons (SPPs) are theoretically investigated at the interface of a dielectric metal and gold. The output pulse from the dielectric is used as the input pulse for the generation of SPPs. The SPPs show soliton-like behavior at the interface. The solitary form of a SPP is maintained under the effects of Kerr nonlinearity, Doppler broadening and Fresnel dragging whereas its phase shift is significantly modified. A 0.3radian phase shift is calculated in the presence of both Kerr nonlinearity and Fresnel dragging in the absence of plasma motion. The phase shift is enhanced to 60radian due to the combined effect of Doppler broadening, Kerr nonlinearity and Fresnel dragging. The results may have significant applications in nano-photonics, optical tweezers, photovoltaic devices, plasmonster and sensing technology.

  12. Prevalence of Rheumatic Heart Disease in a Public School of Belo Horizonte

    OpenAIRE

    Miranda, Lavinia Pimentel; Camargos, Paulo Augusto Moreira; Torres, Rosália Morais; Meira, Zilda Maria Alves

    2014-01-01

    Background: Previous studies indicate that compared with physical examination, Doppler echocardiography identifies a larger number of cases of rheumatic heart disease in apparently healthy individuals. Objectives: To determine the prevalence of rheumatic heart disease among students in a public school of Belo Horizonte by clinical evaluation and Doppler echocardiography. Methods: This was a cross-sectional study conducted with 267 randomly selected school students aged between 6 and ...

  13. Effect of suprathermal electrons on the intensity and Doppler frequency of electron plasma lines

    Directory of Open Access Journals (Sweden)

    P. Guio

    Full Text Available In an incoherent scattering radar experiment, the spectral measurement of the so-called up- and downshifted electron plasma lines provides information about their intensity and their Doppler frequency. These two spectral lines correspond, in the backscatter geometry, to two Langmuir waves travelling towards and away from the radar. In the daytime ionosphere, the presence of a small percentage of photoelectrons produced by the solar EUV of the total electron population can excite or damp these Langmuir waves above the thermal equilibrium, resulting in an enhancement of the intensity of the lines above the thermal level. The presence of photo-electrons also modifies the dielectric response function of the plasma from the Maxwellian and thus influences the Doppler frequency of the plasma lines. In this paper, we present a high time-resolution plasma-line data set collected on the Eiscat VHF radar. The analysed data are compared with a model that includes the effect of a suprathermal electron population calculated by a transport code. By comparing the intensity of the analysed plasma lines data to our model, we show that two sharp peaks in the electron suprathermal distribution in the energy range 20-30 eV causes an increased Landau damping around 24.25 eV and 26.25 eV. We have identified these two sharp peaks as the effect of the photoionisation of N2 and O by the intense flux of monochromatic HeII radiation of wavelength 30.378 nm (40.812 eV created in the chromospheric network and coronal holes. Furthermore, we see that what would have been interpreted as a mean Doppler drift velocity for a Maxwellian plasma is actually a shift of the Doppler frequency of the plasma lines due to suprathermal electrons.

    Key words. Ionosphere (electric fields and currents; solar radiation and cosmic ray effects

  14. Effect of suprathermal electrons on the intensity and Doppler frequency of electron plasma lines

    Directory of Open Access Journals (Sweden)

    P. Guio

    1999-07-01

    Full Text Available In an incoherent scattering radar experiment, the spectral measurement of the so-called up- and downshifted electron plasma lines provides information about their intensity and their Doppler frequency. These two spectral lines correspond, in the backscatter geometry, to two Langmuir waves travelling towards and away from the radar. In the daytime ionosphere, the presence of a small percentage of photoelectrons produced by the solar EUV of the total electron population can excite or damp these Langmuir waves above the thermal equilibrium, resulting in an enhancement of the intensity of the lines above the thermal level. The presence of photo-electrons also modifies the dielectric response function of the plasma from the Maxwellian and thus influences the Doppler frequency of the plasma lines. In this paper, we present a high time-resolution plasma-line data set collected on the Eiscat VHF radar. The analysed data are compared with a model that includes the effect of a suprathermal electron population calculated by a transport code. By comparing the intensity of the analysed plasma lines data to our model, we show that two sharp peaks in the electron suprathermal distribution in the energy range 20-30 eV causes an increased Landau damping around 24.25 eV and 26.25 eV. We have identified these two sharp peaks as the effect of the photoionisation of N2 and O by the intense flux of monochromatic HeII radiation of wavelength 30.378 nm (40.812 eV created in the chromospheric network and coronal holes. Furthermore, we see that what would have been interpreted as a mean Doppler drift velocity for a Maxwellian plasma is actually a shift of the Doppler frequency of the plasma lines due to suprathermal electrons.Key words. Ionosphere (electric fields and currents; solar radiation and cosmic ray effects

  15. The Cognitive Doppler.

    Science.gov (United States)

    Kozoil, Micah E.

    1989-01-01

    Discusses the learning needs of students in the concrete operational stage in mathematics. Identifies the phenomenon of reduced cognitive performance in an out-of-class environment as the "Cognitive Doppler." Suggests methods of reducing the pronounced effects of the Cognitive Doppler by capitalizing on the students' ability to memorize…

  16. Doppler ultrasound exam of an arm or leg

    Science.gov (United States)

    Peripheral vascular disease - Doppler; PVD - Doppler; PAD - Doppler; Blockage of leg arteries - Doppler; Intermittent claudication - Doppler; Arterial insufficiency of the legs - Doppler; Leg pain and ...

  17. Six-beam homodyne laser Doppler vibrometry based on silicon photonics technology.

    Science.gov (United States)

    Li, Yanlu; Zhu, Jinghao; Duperron, Matthieu; O'Brien, Peter; Schüler, Ralf; Aasmul, Soren; de Melis, Mirko; Kersemans, Mathias; Baets, Roel

    2018-02-05

    This paper describes an integrated six-beam homodyne laser Doppler vibrometry (LDV) system based on a silicon-on-insulator (SOI) full platform technology, with on-chip photo-diodes and phase modulators. Electronics and optics are also implemented around the integrated photonic circuit (PIC) to enable a simultaneous six-beam measurement. Measurement of a propagating guided elastic wave in an aluminum plate (speed ≈ 909 m/s @ 61.5 kHz) is demonstrated.

  18. Left Ventricular Function After Prolonged Exercise in Equine Endurance Athletes

    DEFF Research Database (Denmark)

    Flethøj, M.; Schwarzwald, C. C.; Haugaard, M. M.

    2016-01-01

    Doppler imaging, and two-dimensional speckle tracking. Correlation between echocardiographic variables and cardiac troponin I was evaluated. Results: Early diastolic myocardial velocities decreased significantly in longitudinal (baseline: −17.4 ± 2.4cm/s; end of ride: −15.8 ± 3.2cm/s (P = .013); morning......Background: Prolonged exercise in human athletes is associated with transient impairment of left ventricular (LV) function, known as cardiac fatigue. Cardiac effects of prolonged exercise in horses remain unknown. Objectives :To investigate the effects of prolonged exercise on LV systolic...... and diastolic function in horses. Animals: Twenty-six horses competing in 120–160 km endurance rides. Methods: Cross-sectional field study. Echocardiography was performed before and after rides, and the following morning, and included two-dimensional echocardiography, anatomical M-mode, pulsed-wave tissue...

  19. Simulation-based training in echocardiography.

    Science.gov (United States)

    Biswas, Monodeep; Patel, Rajendrakumar; German, Charles; Kharod, Anant; Mohamed, Ahmed; Dod, Harvinder S; Kapoor, Poonam Malhotra; Nanda, Navin C

    2016-10-01

    The knowledge gained from echocardiography is paramount for the clinician in diagnosing, interpreting, and treating various forms of disease. While cardiologists traditionally have undergone training in this imaging modality during their fellowship, many other specialties are beginning to show interest as well, including intensive care, anesthesia, and primary care trainees, in both transesophageal and transthoracic echocardiography. Advances in technology have led to the development of simulation programs accessible to trainees to help gain proficiency in the nuances of obtaining quality images, in a low stress, pressure free environment, often with a functioning ultrasound probe and mannequin that can mimic many of the pathologies seen in living patients. Although there are various training simulation programs each with their own benefits and drawbacks, it is clear that these programs are a powerful tool in educating the trainee and likely will lead to improved patient outcomes. © 2016, Wiley Periodicals, Inc.

  20. Wave mixing spectroscopy

    International Nuclear Information System (INIS)

    Smith, R.W.

    1980-08-01

    Several new aspects of nonlinear or wave mixing spectroscopy were investigated utilizing the polarization properties of the nonlinear output field and the dependence of this field upon the occurrence of multiple resonances in the nonlinear susceptibility. First, it is shown theoretically that polarization-sensitive detection may be used to either eliminate or controllably reduce the nonresonant background in coherent anti-Stokes Raman spectroscopy, allowing weaker Raman resonances to be studied. The features of multi-resonant four-wave mixing are examined in the case of an inhomogeneously broadened medium. It is found that the linewidth of the nonlinear output narrows considerably (approaching the homogeneous width) when the quantum mechanical expressions for the doubly- and triply-resonant susceptibilities are averaged over a Doppler or strain broadened profile. Experimental studies of nonlinear processes in Pr +3 :LaF 3 verify this linewidth narrowing, but indicate that this strain broadened system cannot be treated with a single broadening parameter as in the case of Doppler broadening in a gas. Several susceptibilities are measured from which are deduced dipole matrix elements and Raman polarizabilities related to the 3 H 4 , 3 H 6 , and 3 P 0 levels of the praseodymium ions

  1. Exercise echocardiography in asymptomatic survivors of childhood cancer treated with anthracyclines

    DEFF Research Database (Denmark)

    Sieswerda, Elske; Kremer, Leontien C M; Vidmar, Suzanna

    2010-01-01

    BACKGROUND: Exercise echocardiography reveals abnormalities in asymptomatic childhood cancer survivors who previously have been treated with anthracyclines. We determined the added value of monitoring childhood cancer survivors with exercise echocardiography compared to monitoring with resting ec...

  2. Targeted neonatal echocardiography services: need for standardized training and quality assurance.

    LENUS (Irish Health Repository)

    Finan, Emer

    2014-10-01

    Targeted neonatal echocardiography refers to a focused assessment of myocardial performance and hemodynamics directed by a specific clinical question. It has become the standard of care in many parts of the world, but practice is variable, and there has been a lack of standardized training and evaluation to date. Targeted neonatal echocardiography was first introduced to Canada in 2006. The purpose of this study was to examine the characteristics of targeted neonatal echocardiography practice and training methods in Canadian neonatal intensive care units (NICUs).

  3. The diagnostic ability of echocardiography for infective endocarditis and its associated complications.

    Science.gov (United States)

    Vilacosta, Isidre; Olmos, Carmen; de Agustín, Alberto; López, Javier; Islas, Fabián; Sarriá, Cristina; Ferrera, Carlos; Ortiz-Bautista, Carlos; Sánchez-Enrique, Cristina; Vivas, David; San Román, Alberto

    2015-11-01

    Echocardiography, transthoracic and transoesophageal, plays a key role in the diagnosis and prognosis assessment of patients with infective endocarditis. It constitutes a major Duke criterion and is pivotal in treatment guiding. Seven echocardiographic findings are major criteria in the diagnosis of infective endocarditis (IE) (vegetation, abscess, pseudoaneurysm, fistulae, new dehiscence of a prosthetic valve, perforation and valve aneurysm). Echocardiography must be performed as soon as endocarditis is suspected. Transoesophageal echocardiography should be done in most cases of left-sided endocarditis to better define the anatomic lesions and to rule out local complications. Transoesophageal echocardiography is not necessary in isolated right-sided native valve IE with good quality transthoracic examination and unequivocal echocardiographic findings. Echocardiography is a very useful tool to assess the prognosis of patients with IE at any time during the course of the disease. Echocardiographic predictors of poor outcome include presence of periannular complications, prosthetic dysfunction, low left ventricular ejection fraction, pulmonary hypertension and very large vegetations.

  4. DOBUTAMINE STRESS-ECHOCARDIOGRAPHY: POSSIBILITY OF CLINICAL USAGE IN CARDIOLOGY PRACTICE

    Directory of Open Access Journals (Sweden)

    M. A. Saidova

    2016-01-01

    Full Text Available Currently stress-echocardiography or so-called burden echocardiography is essential method of patient examination to reveal latent ischemic heart disease (IHD. That is one of the mostly informative non-invasive methods of IHD diagnosis as well as efficacy evaluation of coronary angioplasty, surgical and pharmacological treatments of IHD. Dobutamine usage as a stress-agent at burden echocardiography allows evaluating not only ischemia but a myocardial vitality in post infarction area as well as clarify severity of valve stenosis, pulmonary hypertension and extent of latent obstruction of exhaust duct of the left ventricle. Method possibilities are presented as well as test protocol, main indications and contraindications.

  5. Left ventricular outflow tract to left atrial communication secondary to rupture of mitral-aortic intervalvular fibrosa in infective endocarditis: diagnosis by transesophageal echocardiography and color flow imaging.

    Science.gov (United States)

    Bansal, R C; Graham, B M; Jutzy, K R; Shakudo, M; Shah, P M

    1990-02-01

    Infection of the mitral-aortic intervalvular fibrosa occurs most commonly in association with infective endocarditis of the aortic valve. Infection of the aortic valve results in a regurgitant jet that presumably strikes this subaortic interannular zone of fibrous tissue and produces a secondary site of infection. Infection of this interannular zone then leads to the formation of subaortic abscess or pseudoaneurysm of the left ventricular outflow tract. This infected zone of mitral-aortic intervalvular fibrosa or subaortic aneurysm can subsequently rupture into the left atrium with systolic ejection of blood from the left ventricular outflow tract to the left atrium. This report describes the echocardiographic findings in three patients with pathologically proved left ventricular outflow tract to left atrial communication. Precise preoperative diagnosis is important, and this lesion should be differentiated from ruptured aneurysm of the sinus of Valsalva and perforation of the anterior mitral leaflet. Transthoracic echocardiography using color flow imaging and conventional Doppler techniques may show an eccentric mitral regurgitation type of signal in the left atrium originating from the region of the left ventricular outflow tract. However, transesophageal echocardiography provides an accurate preoperative diagnosis and should be used intraoperatively during repair of such lesions.

  6. Simplified single plane echocardiography is comparable to conventional biplane two-dimensional echocardiography in the evaluation of left atrial volume: a study validated by three-dimensional echocardiography in 143 individuals.

    Science.gov (United States)

    Vieira-Filho, Normando G; Mancuso, Frederico J N; Oliveira, Wercules A A; Gil, Manuel A; Fischer, Cláudio H; Moises, Valdir A; Campos, Orlando

    2014-03-01

    The left atrial volume index (LAVI) is a biomarker of diastolic dysfunction and a predictor of cardiovascular events. Three-dimensional echocardiography (3DE) is highly accurate for LAVI measurements but is not widely available. Furthermore, biplane two-dimensional echocardiography (B2DE) may occasionally not be feasible due to a suboptimal two-chamber apical view. Simplified single plane two-dimensional echocardiography (S2DE) could overcome these limitations. We aimed to compare the reliability of S2DE with other validated echocardiographic methods in the measurement of the LAVI. We examined 143 individuals (54 ± 13 years old; 112 with heart disease and 31 healthy volunteers; all with sinus rhythm, with a wide range of LAVI). The results for all the individuals were compared with B2DE-derived LAVIs and validated using 3DE. The LAVIs, as determined using S2DE (32.7 ± 13.1 mL/m(2)), B2DE (31.9 ± 12.7 mL/m(2)), and 3DE (33.1 ± 13.4 mL/m(2)), were not significantly different from each other (P = 0.85). The S2DE-derived LAVIs correlated significantly with those obtained using both B2DE (r = 0.98; P < 0.001) and 3DE (r = 0.93; P < 0.001). The mean difference between the S2DE and B2DE measurements was <1.0 mL/m(2). Using the American Society of Echocardiography criteria for grading LAVI enlargement (normal, mild, moderate, severe), we observed an excellent agreement between the S2DE- and B2DE-derived classifications (κ = 0.89; P < 0.001). S2DE is a simple, rapid, and reliable method for LAVI measurement that may expand the use of this important biomarker in routine echocardiographic practice. © 2013, Wiley Periodicals, Inc.

  7. Doppler flowmetry in preeclampsia.

    Science.gov (United States)

    Zahumensky, J

    2009-01-01

    The purpose of this study was to summarize the new published data on the Doppler flowmetry in preeclampsia. We summarize the new published data on the Doppler flowmetry in uteroplacental, fetoplacental and fetal circulation in preeclampsia. The present review summarized the results of clinical research on the Doppler flowmetry in the screening of risk of preclampsia, in the diagnosis of preclampsia and in the fetal risk in preclampsia (Ref. 19). Full Text (Free, PDF) www.bmj.sk.

  8. Middle Atmosphere Dynamics with Gravity Wave Interactions in the Numerical Spectral Model: Tides and Planetary Waves

    Science.gov (United States)

    Mayr, Hans G.; Mengel, J. G.; Chan, K. L.; Huang, F. T.

    2010-01-01

    As Lindzen (1981) had shown, small-scale gravity waves (GW) produce the observed reversals of the zonal-mean circulation and temperature variations in the upper mesosphere. The waves also play a major role in modulating and amplifying the diurnal tides (DT) (e.g., Waltersheid, 1981; Fritts and Vincent, 1987; Fritts, 1995a). We summarize here the modeling studies with the mechanistic numerical spectral model (NSM) with Doppler spread parameterization for GW (Hines, 1997a, b), which describes in the middle atmosphere: (a) migrating and non-migrating DT, (b) planetary waves (PW), and (c) global-scale inertio gravity waves. Numerical experiments are discussed that illuminate the influence of GW filtering and nonlinear interactions between DT, PW, and zonal mean variations. Keywords: Theoretical modeling, Middle atmosphere dynamics, Gravity wave interactions, Migrating and non-migrating tides, Planetary waves, Global-scale inertio gravity waves.

  9. Steerable Doppler transducer probes

    International Nuclear Information System (INIS)

    Fidel, H.F.; Greenwood, D.L.

    1986-01-01

    An ultrasonic diagnostic probe is described which is capable of performing ultrasonic imaging and Doppler measurement consisting of: a hollow case having an acoustic window which passes ultrasonic energy and including chamber means for containing fluid located within the hollow case and adjacent to a portion of the acoustic window; imaging transducer means, located in the hollow case and outside the fluid chamber means, and oriented to direct ultrasonic energy through the acoustic window toward an area which is to be imaged; Doppler transducer means, located in the hollow case within the fluid chamber means, and movably oriented to direct Doppler signals through the acoustic window toward the imaged area; means located within the fluid chamber means and externally controlled for controllably moving the Doppler transducer means to select one of a plurality of axes in the imaged area along which the Doppler signals are to be directed; and means, located external to the fluid chamber means and responsive to the means for moving, for providing an indication signal for identifying the selected axis

  10. Developing de Broglie Wave

    Directory of Open Access Journals (Sweden)

    Zheng-Johansson J. X.

    2006-10-01

    Full Text Available The electromagnetic component waves, comprising together with their generating oscillatory massless charge a material particle, will be Doppler shifted when the charge hence particle is in motion, with a velocity v, as a mere mechanical consequence of the source motion. We illustrate here that two such component waves generated in opposite directions and propagating at speed c between walls in a one-dimensional box, superpose into a traveling beat wave of wavelength Λd=vcΛ and phase velocity c2/v+v which resembles directly L. de Broglie’s hypothetic phase wave. This phase wave in terms of transmitting the particle mass at the speed v and angular frequency Ωd= 2πv/Λd, with Λd and Ωd obeying the de Broglie relations, represents a de Broglie wave. The standing-wave function of the de Broglie (phase wave and its variables for particle dynamics in small geometries are equivalent to the eigen-state solutions to Schrödinger equation of an identical system.

  11. Doppler Radar Vital Signs Detection Method Based on Higher Order Cyclostationary.

    Science.gov (United States)

    Yu, Zhibin; Zhao, Duo; Zhang, Zhiqiang

    2017-12-26

    Due to the non-contact nature, using Doppler radar sensors to detect vital signs such as heart and respiration rates of a human subject is getting more and more attention. However, the related detection-method research meets lots of challenges due to electromagnetic interferences, clutter and random motion interferences. In this paper, a novel third-order cyclic cummulant (TOCC) detection method, which is insensitive to Gaussian interference and non-cyclic signals, is proposed to investigate the heart and respiration rate based on continuous wave Doppler radars. The k -th order cyclostationary properties of the radar signal with hidden periodicities and random motions are analyzed. The third-order cyclostationary detection theory of the heart and respiration rate is studied. Experimental results show that the third-order cyclostationary approach has better estimation accuracy for detecting the vital signs from the received radar signal under low SNR, strong clutter noise and random motion interferences.

  12. A guideline update for the practice of echocardiography in the cardiac screening of sports participants: a joint policy statement from the British Society of Echocardiography and Cardiac Risk in the Young

    Directory of Open Access Journals (Sweden)

    David Oxborough PhD

    2018-03-01

    Full Text Available Sudden cardiac death (SCD in an athlete is a rare but tragic event. In view of this, pre-participation cardiac screening is mandatory across many sporting disciplines to identify those athletes at risk. Echocardiography is a primary investigation utilized in the pre-participation setting and in 2013 the British Society of Echocardiography and Cardiac Risk in the Young produced a joint policy document providing guidance on the role of echocardiography in this setting. Recent developments in our understanding of the athlete’s heart and the application of echocardiography have prompted this 2018 update.

  13. ECHOCARDIOGRAPHY BASED STUDY OF THE PREVALENCE AND PATTERN OF CONGENITAL HEART DISEASE (CHD IN 5-15 YEARS OLD SCHOOL GOING CHILDREN OF MANIPUR, A NORTH-EAST HILLY INDIAN STATE

    Directory of Open Access Journals (Sweden)

    Rajendra Singh Thangjam

    2017-12-01

    Full Text Available BACKGROUND CHD is the leading cause of morbidity and mortality in the developed world, while reports from India looking into the burden of the disease have been variable depending on the age group of subjects studied and the methodology involved. We were interested to find the prevalence and pattern of the disease in this north eastern Indian state of Manipur, which has a unique geographical and racial composition. MATERIALS AND METHODS This is a community based, prospective, cross sectional study where each and every child aged 5-15 years from randomly selected schools of Manipur were examined by 2D colour Doppler Echocardiography and physically as well, where the examiners were blinded, and the findings were noted independent of each other. The anthropometric parameters, clinical details and echocardiography findings were all recorded. RESULTS Of the 3600 children examined, 47 cases of CHD were detected, giving echocardiographic prevalence of 13 per 1000 where BAV (44% was found as the commonest lesion followed by VSD (17% and ASD (14%. Clinically detectable lesion was found in 21 subjects (VSD -8, ASD-7, PS-3, PDA -1, AVSD-1, BAV-1 with AR. Of the clinically detectable CHD, VSD was the commonest followed by ASD. In the subclinical CHD category, 20 cases of BAV, 4 cases of mild MVP without MR, 1 case of apical LV discompacta, 1 case of IASA were detected. CONCLUSION The echocardiography prevalence of congenital heart disease in school going children of Manipur is 13/1000. This highest ever reported prevalence of CHD in children is most probably related to the use of the highly sensitive investigative tool of Echocardiography in each subject of our study resulting in detection of clinically silent lesions.

  14. Evaluation of echocardiography in the management of elderly patients with heart failure.

    Science.gov (United States)

    Hendry, A; Hacking, L; Langhorne, P; Vallance, R; MacDonald, J

    1999-09-01

    To determine the validity of a clinical diagnosis of systolic dysfunction in elderly patients with heart failure and assess the contribution of echocardiography to their management. 61 elderly patients with a diagnosis of heart failure in a geriatric assessment unit setting. Prospective study determining sensitivity, specificity and predictive values of a clinical and radiological diagnosis compared with echocardiographic standard. Proposed management was compared before and after echocardiography. Clinical assessment was highly sensitive (93%) but lacked specificity (32%). Combining radiological and clinical diagnoses increased specificity to 58%. Echocardiography revised the lead cardiac diagnosis for 28% of patients and influenced patient management plans for 41%. For elderly patients with heart failure, echocardiography improves diagnostic accuracy and identifies those patients with potential to benefit from angiotensin-converting enzyme inhibitors.

  15. Modeling of Doppler frequency shift in multipath radio channels

    Directory of Open Access Journals (Sweden)

    Penzin M.S.

    2016-06-01

    Full Text Available We discuss the modeling of propagation of a quasi-monochromatic radio signal, represented by a coherent pulse sequence, in a non-stationary multipath radio channel. In such a channel, signal propagation results in the observed frequency shift for each ray (Doppler effect. The modeling is based on the assumption that during propagation of a single pulse a channel can be considered stationary. A phase variation in the channel transfer function is shown to cause the observed frequency shift in the received signal. Thus, instead of measuring the Doppler frequency shift, we can measure the rate of variation in the mean phase of one pulse relative to another. The modeling is carried out within the framework of the method of normal waves. The method enables us to model the dynamics of the electromagnetic field at a given point with the required accuracy. The modeling reveals that a local change in ionospheric conditions more severely affects the rays whose reflection region is in the area where the changes occur.

  16. Spatial weighting of Doppler reactivity feedback

    International Nuclear Information System (INIS)

    Carew, J.F.; Diamond, D.J.; Todosow, M.

    1977-12-01

    The spatial weighting of the local Doppler feedback implicit in the determination of the core Doppler feedback reactivity has been investigated. Using a detailed planar PDQ7-II PWR model with local fuel-temperature feedback, the core Doppler spatial weight factor, S, has been determined for various control patterns and power levels. Assuming power-squared weighting of the local Doppler feedback, a simple analytic expression for S has been derived and, based on comparison with the PDQ7-II results, provides a convenient and accurate representation of the Doppler spatial weight factor. The sensitivity of these results to variations in the fuel rod heat transfer coefficients, fuel loading and the magnitude of the Doppler coefficient has also been evaluated. The dependence of the local Doppler coefficient on moderator temperature, boron concentration and control rod density has been determined and found to be weak. Selected comparisons with vendor analyses have been made and indicate general agreement

  17. Echocardiography in patients with complications related to pacemakers and cardiac defibrillators.

    Science.gov (United States)

    Almomani, Ahmed; Siddiqui, Khadija; Ahmad, Masood

    2014-03-01

    The evolving indications and uses for implantable cardiac devices have led to a significant increase in the number of implanted devices each year. Implantation of endocardial leads for permanent pacemakers and cardiac defibrillators can cause many delayed complications. Complications may be mechanical and related to the interaction of the device leads with the valves and endomyocardium, e.g., perforation, infection, and thrombosis, or due to the electrical pacing of the myocardium and conduction abnormalities, e.g., left ventricular dyssynchrony. Tricuspid regurgitation, another delayed complication in these patients, may be secondary to both mechanical and pacing effects of the device leads. Echocardiography plays an important role in the diagnosis of these device-related complications. Both two-dimensional transthoracic echocardiography and transesophageal echocardiography provide useful diagnostic information. Real time three-dimensional echocardiography is a novel technique that can further enhance the detection of lead-related complications. © 2013, Wiley Periodicals, Inc.

  18. Effects of negative T wave in electrocardiography on prognosis of post-myocardial infarction patients

    Directory of Open Access Journals (Sweden)

    Reza Karbasi-Afshar

    2013-03-01

    Full Text Available BACKGROUND: Negative T (NT wave in electrocardiography (ECG is one of the important factors in determining short- and long-term outcomes in patients with acute myocardial infarction (MI. In this study, we compared clinical and paraclinical findings in post-MI patients according to presence or absence of NT wave. METHODS: A cross-sectional study was conducted on patients with acute ST elevation MI who presented to Shahid Modares Hospital (Tehran, Iran during 2009-10. After undergoing streptokinase therapy, demographic characteristics and ECG and exercise test findings of the subjects were compared based on the presence or absence of NT wave. RESULTS: Overall, 116 patients including 69 cases with NT wave (NT group and 47 cases without NT wave (PT group were enrolled (mean age: 53.7 ± 7.1 vs. 54.1 ± 6.8 years old. Mortality rate during the first five days was 13% in the NT group and 29% in the PT group (P < 0.05. Ejection fraction values of the NT group were significantly higher than the PT group (P = 0.005. However, left ventricular end-diastolic diameter of the NT group was significantly less than the PT group (P = 0.005. Moreover, ST segment depression was significantly less frequent in the NT group compared to the PT group. CONCLUSION: Patients with ST elevation MI accompanying with NT wave in ECG versus have better prognosis and myocardial function than similar patients without NT wave. Therefore, invasive procedures should be recommended for patients without NT wave.   Keywords: Echocardiography, Exercise Test, Myocardial Infarction, Negative T Wave, Echocardiography

  19. Intraoperative echocardiography of a dislodged Björk-Shiley mitral valve disc.

    Science.gov (United States)

    Tanaka, M; Abe, T; Takeuchi, E; Watanabe, T; Tamaki, S

    1991-02-01

    The successful management of a patient who suffered an outlet strut fracture of a Björk-Shiley 60-degree convexo-concave mitral valve prosthesis is reported. Emergency operation was life-saving. Preoperative echocardiography assisted in making a prompt diagnosis, and intraoperative echocardiography allowed the detection and removal of the dislodged disc from the left ventricle at the time of the operation. The role of intraoperative echocardiography in the diagnosis of prosthetic strut fracture is emphasized.

  20. Visualization of traumatic tricuspid insufficiency by three-dimensional echocardiography.

    Science.gov (United States)

    Nishimura, Kazuhisa; Okayama, Hideki; Inoue, Katsuji; Saito, Makoto; Nagai, Takayuki; Suzuki, Jun; Ogimoto, Akiyoshi; Ohtsuka, Tomoaki; Higaki, Jitsuo

    2010-01-01

    A 19-year-old male was admitted to the emergency room of our hospital after a motor vehicle accident. During his first physical examination, a holosystolic murmur was heard at the fourth left parasternal border. Transthoracic echocardiography showed severe tricuspid insufficiency, but the cause of tricuspid insufficiency was unclear. Therefore, three-dimensional echocardiography was performed and demonstrated flail anterior, posterior and septal leaflets of the tricuspid valve. The diagnosis was tricuspid insufficiency due to papillary muscle rupture secondary to chest blunt trauma. Surgical repair of the tricuspid valve was performed in this patient. After surgery, the signs and symptoms of right ventricular heart failure were relieved. In this case, three-dimensional echocardiography was very useful for the evaluation of spatial destruction of the tricuspid valve and papillary muscle. 2009 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  1. Comparative study of the performance of semiconductor laser based coherent Doppler lidars

    DEFF Research Database (Denmark)

    Rodrigo, Peter John; Pedersen, Christian

    2012-01-01

    Coherent Doppler Lidars (CDLs), operating at an eye-safe 1.5-micron wavelength, have found promising applications in the optimization of wind-power production. To meet the wind-energy sector's impending demand for more cost-efficient industrial sensors, we have focused on the development of conti......Coherent Doppler Lidars (CDLs), operating at an eye-safe 1.5-micron wavelength, have found promising applications in the optimization of wind-power production. To meet the wind-energy sector's impending demand for more cost-efficient industrial sensors, we have focused on the development...... of continuous-wave CDL systems using compact, inexpensive semiconductor laser (SL) sources. In this work, we compare the performance of two candidate emitters for an allsemiconductor CDL system: (1) a monolithic master-oscillator-power-amplifier (MOPA) SL and (2) an external-cavity tapered diode laser (ECTDL)....

  2. Understanding the Doppler Effect by Analysing Spectrograms of the Sound of a Passing Vehicle

    Science.gov (United States)

    Lubyako, Dmitry; Martinez-Piedra, Gordon; Ushenin, Arthur; Ushenin, Arthur; Denvir, Patrick; Dunlop, John; Hall, Alex; Le Roux, Gus; van Someren, Laurence; Weinberger, Harvey

    2017-01-01

    The purpose of this paper is to demonstrate how the Doppler effect can be analysed to deduce information about a moving source of sound waves. Specifically, we find the speed of a car and the distance of its closest approach to an observer using sound recordings from smartphones. A key focus of this paper is how this can be achieved in a…

  3. Usefulness of exercise echocardiography in ischemic heart disease. Comparison with exercise cardiac scintigraphy

    International Nuclear Information System (INIS)

    Tashiro, Hideki; Koyanagi, Samon; Narabayashi, Hideki; Inou, Tetsuji; Takeshita, Akira

    1999-01-01

    Exercise echocardiography and exercise thallium-201 ( 201 Tl) single photon emission computed tomography (SPECT) were performed in 152 patients with suspected coronary artery disease, including 61 patients with old myocardial infarction. All patients underwent coronary arteriography, and coronary artery disease was defined as ≥75% diameter stenosis. Digital two-dimensional echocardiography was performed before and after the treadmill exercise test, and wall motion abnormality was evaluated using quad-screen. Sensitivity and specificity for the diagnosis of coronary artery disease were similar for the 2 exercise tests (77% and 80% for echocardiography and 75%, and 83% for SPECT, respectively). Diagnoses for one-vessel disease, 2-vessel disease and 3-vessel disease were similar for echocardiography (79%, 72% and 77%, respectively) and SPECT (74%, 75% and 77%, respectively). Sensitivity for the diagnosis of ischemia at the area remote from infarct area was low for both exercise echocardiography and exercise SPECT (45% and 48%, respectively). Exercise echocardiography has comparable diagnostic value to SPECT for the detection of coronary artery disease. However, both exercise tests have limitations for the diagnosis of ischemia at the area remote from infarct area. (author)

  4. The role of colour flow Doppler in the investigation of the salivary gland tumour

    International Nuclear Information System (INIS)

    Bradley, M.J.; Durham, L.H.; Lancer, J.M.

    2000-01-01

    AIMS: Ultrasound is a highly effective imaging technique to determine salivary gland tumours and may help to identify many benign lesions. The aim of this study is to evaluate whether colour Doppler is able to further differentiate the malignant tumour. METHODS: Fifty-six patients with salivary gland lesions were prospectively assessed using ultrasound imaging with colour flow and power Doppler. The peak systolic velocity (PSV) was measured and the pulsatility index (PI) and resistive index (RI) calculations were performed on the pulsed wave traces. The real time ultrasound morphology and the Doppler information were correlated with the histology. RESULTS: In 18 of the 56 patients, no internal colour flow or power Doppler changes could be detected. The real time ultrasound morphology diagnosed benign disease with sensitivity of 89.7% with specificity of 57.1%. The positive predictive value was 93.6%. There were no significant differences in the colour Doppler appearances in terms of vessel type or intratumour distribution which could separate benign from malignant conditions. However, there was statistical discrimination for PI and RI values (P = 0.0006, P = 0.0002, respectively). No malignant lesions were seen when the PI was less than 1.8 and RI was less than 0.8. The PSV was elevated in several cases (> 50 cm per s) but there was no statistical correlation with malignancy. CONCLUSION: The risk of malignancy increases by a third when the colour Doppler demonstrates increased intratumour vascular resistance (RI > 0.8 and PI > 1.8), with positive predictive value of 97.3% (sensitivity 75.5%, specificity 85.7%). Bradley, M.J. (2000). Clinical Radiology 55, 759-762

  5. Three-dimensional transesophageal echocardiography of the atrial septal defects

    Directory of Open Access Journals (Sweden)

    Romero-Cárdenas Ángel

    2008-07-01

    Full Text Available Abstract Transesophageal echocardiography has advantages over transthoracic technique in defining morphology of atrial structures. Even though real time three-dimensional echocardiographic imaging is a reality, the off-line reconstruction technique usually allows to obtain higher spatial resolution images. The purpose of this study was to explore the accuracy of off-line three-dimensional transesophageal echocardiography in a spectrum of atrial septal defects by comparing them with representative anatomic specimens.

  6. B-mode and Doppler ultrasonography of adrenal glands of healthy dogs

    Directory of Open Access Journals (Sweden)

    S. Fernandez

    2016-08-01

    Full Text Available ABSTRACT The aim of this study was to determine the vascular indices of adrenal blood flow in healthy dogs (systolic velocity - SV; diastolic velocity - DV; resistance index - RI. Eighteen dogs (thirty six adrenal were studied. Physical examination, biochemical profile and dexamethasone suppression test were performed to determine general health status. Echotexture, size, contours and margins, and overall shape of the adrenal gland (right and left were assessed via ultrasound. By spectral Doppler of the phrenic-abdominal artery, the SV, DV, and RI were acquired. Animals did not show alterations in clinical and laboratory examination and suppression of cortisol. Normal homogeneous and echotexture, regular contours and margins and normal shape and size were verified via B mode. Spectral Doppler of the phrenic-abdominal artery showed monophasic-patterned waves and low vascular resistance and systolic peak evident with means values: left adrenal - SV = 31.34cm/s, DV = 9.54cm/s and RI = 0.69; and right adrenal - SV = 27.83cm/s, DV = 7.71cm/s and RI = 0.68. Doppler evaluation of adrenal was easily implemented and may provide base line data in the study, allowing for the use of this technique as a diagnostic tool for diseases of the dog's adrenal.

  7. Factors associated with diagnostic discrepancy for left ventricular hypertrophy between electrocardiography and echocardiography

    DEFF Research Database (Denmark)

    Sandager Petersen, Søren; Reinholdt Pedersen, Line; Pareek, Manan

    2017-01-01

    (absolute value/cut-off value for LVH) were used as outcome variables in order to identify explanatory variables associated with diagnostic discrepancies between ECG and echocardiography. RESULTS: Of the 1382 subjects included, 77% did not display any signs of LVH, 6% had LVH defined by ECG only, 13% had...... LVH defined by echocardiography only, and 5% had LVH on both ECG and echocardiography. Older subjects and those with higher blood pressure and RWT were more likely to have a relatively greater LVMI on echocardiography than that predicted on ECG (odds ratio: 1.65 per 10 years (95% confidence interval...... and odds ratio: 1.41 (95% CI: 1.06-1.87), p = .02), but FPG did not independently influence discrepancy between ECG and echocardiography. CONCLUSION: Age, blood pressure, female sex, greater RWT and use of antihypertensive medication were associated with a greater risk of non-consistency between LVH...

  8. Nonlinear MHD Waves in a Prominence Foot

    Science.gov (United States)

    Ofman, L.; Knizhnik, K.; Kucera, T.; Schmieder, B.

    2015-11-01

    We study nonlinear waves in a prominence foot using a 2.5D MHD model motivated by recent high-resolution observations with Hinode/Solar Optical Telescope in Ca ii emission of a prominence on 2012 October 10 showing highly dynamic small-scale motions in the prominence material. Observations of Hα intensities and of Doppler shifts show similar propagating fluctuations. However, the optically thick nature of the emission lines inhibits a unique quantitative interpretation in terms of density. Nevertheless, we find evidence of nonlinear wave activity in the prominence foot by examining the relative magnitude of the fluctuation intensity (δI/I ˜ δn/n). The waves are evident as significant density fluctuations that vary with height and apparently travel upward from the chromosphere into the prominence material with quasi-periodic fluctuations with a typical period in the range of 5-11 minutes and wavelengths <2000 km. Recent Doppler shift observations show the transverse displacement of the propagating waves. The magnetic field was measured with the THEMIS instrument and was found to be 5-14 G. For the typical prominence density the corresponding fast magnetosonic speed is ˜20 km s-1, in qualitative agreement with the propagation speed of the detected waves. The 2.5D MHD numerical model is constrained with the typical parameters of the prominence waves seen in observations. Our numerical results reproduce the nonlinear fast magnetosonic waves and provide strong support for the presence of these waves in the prominence foot. We also explore gravitational MHD oscillations of the heavy prominence foot material supported by dipped magnetic field structure.

  9. NONLINEAR MHD WAVES IN A PROMINENCE FOOT

    Energy Technology Data Exchange (ETDEWEB)

    Ofman, L. [Catholic University of America, Washington, DC 20064 (United States); Knizhnik, K.; Kucera, T. [NASA Goddard Space Flight Center, Code 671, Greenbelt, MD 20771 (United States); Schmieder, B. [LESIA, Observatoire de Paris, PSL Research University, CNRS, Sorbonne Universités, UPMC Univ. Paris 06, Univ. Paris-Diderot, Sorbonne Paris Cit, 5 place Jules Janssen, F-92195 Meudon (France)

    2015-11-10

    We study nonlinear waves in a prominence foot using a 2.5D MHD model motivated by recent high-resolution observations with Hinode/Solar Optical Telescope in Ca ii emission of a prominence on 2012 October 10 showing highly dynamic small-scale motions in the prominence material. Observations of Hα intensities and of Doppler shifts show similar propagating fluctuations. However, the optically thick nature of the emission lines inhibits a unique quantitative interpretation in terms of density. Nevertheless, we find evidence of nonlinear wave activity in the prominence foot by examining the relative magnitude of the fluctuation intensity (δI/I ∼ δn/n). The waves are evident as significant density fluctuations that vary with height and apparently travel upward from the chromosphere into the prominence material with quasi-periodic fluctuations with a typical period in the range of 5–11 minutes and wavelengths <2000 km. Recent Doppler shift observations show the transverse displacement of the propagating waves. The magnetic field was measured with the THEMIS instrument and was found to be 5–14 G. For the typical prominence density the corresponding fast magnetosonic speed is ∼20 km s{sup −1}, in qualitative agreement with the propagation speed of the detected waves. The 2.5D MHD numerical model is constrained with the typical parameters of the prominence waves seen in observations. Our numerical results reproduce the nonlinear fast magnetosonic waves and provide strong support for the presence of these waves in the prominence foot. We also explore gravitational MHD oscillations of the heavy prominence foot material supported by dipped magnetic field structure.

  10. Numerical study of glare spot phase Doppler anemometry

    Science.gov (United States)

    Hespel, C.; Ren, K. F.; Gréhan, G.; Onofri, F.

    2008-03-01

    The phase Doppler anemometry has (PDA) been developed to measure simultaneously the velocity and the size of droplets. When the concentration of particles is high, tightly focused beams must be used, as in the dual burst PDA. The latter permits an access to the refractive index of the particle, but the effect of wave front curvature of the incident beams becomes evident. In this paper, we introduce a glare spot phase Doppler anemometry which uses two large beams. The images of the particle formed by the reflected and refracted light, known as glare spots, are separated in space. When a particle passes through the probe volume, the two parts in a signal obtained by a detector in forward direction are then separated in time. If two detectors are used the phase differences and the intensity ratios between two signals, the distance between the reflected and refracted spots can be obtained. These measured values provide information about the particle diameter and its refractive index, as well as its two velocity components. This paper is devoted to the numerical study of such a configuration with two theoretical models: geometrical optics and rigorous electromagnetism solution.

  11. Dynamic cycling in atrial size and flow during obstructive apnoea.

    Science.gov (United States)

    Pressman, Gregg S; Cepeda-Valery, Beatriz; Codolosa, Nicolas; Orban, Marek; Samuel, Solomon P; Somers, Virend K

    2016-01-01

    Obstructive sleep apnoea (OSA) is strongly associated with cardiovascular disease. However, acute cardiovascular effects of repetitive airway obstruction are poorly understood. While past research used a sustained Mueller manoeuver to simulate OSA we employed a series of gasping efforts to better simulate true obstructive apnoeas. This report describes acute changes in cardiac anatomy and flow related to sudden changes in intrathoracic pressure. 26 healthy, normal weight participants performed 5-6 gasping efforts (target intrathoracic pressure -40 mm Hg) while undergoing Doppler echocardiography. 14 participants had sufficient echocardiographic images to allow comparison of atrial areas during the manoeuver with baseline measurements. Mitral and tricuspid E-wave and A-wave velocities postmanoeuver were compared with baseline in all participants. Average atrial areas changed little during the manoeuver, but variance in both atrial areas was significantly greater than baseline. Further, an inverse relationship was noted with left atrial collapse and right atrial enlargement at onset of inspiratory effort. Significant inverse changes were noted in Doppler flow when comparing the first beat postmanoeuver (pMM1) with baseline. Mitral E-wave velocity increased 9.1 cm/s while tricuspid E-wave velocity decreased 7.0 cm/s; by the eighth beat postmanoeuver (pMM8) values were not different from baseline. Mitral and tricuspid A-wave velocities were not different from baseline at pMM1, but both were significantly higher by pMM8. Repetitive obstructive apnoeas produce dynamic, inverse changes in atrial size and Doppler flow across the atrioventricular valves. These observations have important implications for understanding the pathophysiology of OSA.

  12. Measurement of two-dimensional Doppler wind fields using a field widened Michelson interferometer.

    Science.gov (United States)

    Langille, Jeffery A; Ward, William E; Scott, Alan; Arsenault, Dennis L

    2013-03-10

    An implementation of the field widened Michelson concept has been applied to obtain high resolution two-dimensional (2D) images of low velocity (interferometer scanning mirror position is controlled to subangstrom precision with subnanometer repeatability using the multi-application low-voltage piezoelectric instrument control electronics developed by COM DEV Ltd.; it is the first implementation of this system as a phase stepping Michelson. In this paper the calibration and characterization of the Doppler imaging system is described and the planned implementation of this new technique for imaging 2D wind and irradiance fields using the earth's airglow is introduced. Observations of Doppler winds produced by a rotating wheel are reported and shown to be of sufficient precision for buoyancy wave observations in airglow in the mesopause region of the terrestrial atmosphere.

  13. Correlation between the tissue Doppler, strain rate, strain imaging during the dobutamine infusion and coronary fractional flow reserve during catheterization: a comparative study.

    Science.gov (United States)

    Dagdelen, Sinan; Yuce, Murat; Emiroglu, Yunus; Ergelen, Mehmet; Pala, Selcuk; Tanalp, Ali Cevat; Izgi, Akin; Kirma, Cevat

    2005-06-22

    Coronary fractional flow reserve (FFR) as an invasive, and dobutamine stress echocardiography (DSE) as a noninvasive technique were used to detect critical coronary stenosis. This study was undertaken to assess correlation between these two techniques by using tissue Doppler, strain rate (SR), and strain imaging (S). In 17 patients (aged 54.9+/-12.6, 4 F), a total of 22 vessels were studied. On dobutamine stress echocardiography, baseline and peak systolic (Sm), early (Em) and late (Am) diastolic myocardial velocities, SR and S were recorded from parasternal view (mid-posterior segment) for radial and apical view (mid-septum) for longitudinal deformation. Then coronary FFR was performed by using intracoronary adenosine infusion, and the value of system were analyzed for longitudinal SR and S values, it had a mild correlation with SR (r = 0.47, p = 0.044) and a good correlation with S (r = 0.66, p = 0.002). The quantification of regional myocardial deformation by using DSE rather than the motion would be more appropriate in detecting the ischemic dysfunctional segment supplied by the critical coronary stenosis. Strain measurement during the dobutamine infusion may provide an information on the FFR results of the culprit vessel.

  14. Ultrasonic colour Doppler imaging

    DEFF Research Database (Denmark)

    Evans, David H; Jensen, Jørgen Arendt; Nielsen, Michael Bachmann

    2011-01-01

    Ultrasonic colour Doppler is an imaging technique that combines anatomical information derived using ultrasonic pulse-echo techniques with velocity information derived using ultrasonic Doppler techniques to generate colour-coded maps of tissue velocity superimposed on grey-scale images of tissue...... anatomy. The most common use of the technique is to image the movement of blood through the heart, arteries and veins, but it may also be used to image the motion of solid tissues such as the heart walls. Colour Doppler imaging is now provided on almost all commercial ultrasound machines, and has been...

  15. The effect of blood acceleration on the ultrasound power Doppler spectrum

    Science.gov (United States)

    Matchenko, O. S.; Barannik, E. A.

    2017-09-01

    The purpose of the present work was to study the influence of blood acceleration and time window length on the power Doppler spectrum for Gaussian ultrasound beams. The work has been carried out on the basis of continuum model of the ultrasound scattering from inhomogeneities in fluid flow. Correlation function of fluctuations has been considered for uniformly accelerated scatterers, and the resulting power Doppler spectra have been calculated. It is shown that within the initial phase of systole uniformly accelerated slow blood flow in pulmonary artery and aorta tends to make the correlation function about 4.89 and 7.83 times wider, respectively, than the sensitivity function of typical probing system. Given peak flow velocities, the sensitivity function becomes, vice versa, about 4.34 and 3.84 times wider, respectively, then the correlation function. In these limiting cases, the resulting spectra can be considered as Gaussian. The optimal time window duration decreases with increasing acceleration of blood flow and equals to 11.62 and 7.54 ms for pulmonary artery and aorta, respectively. The width of the resulting power Doppler spectrum is shown to be defined mostly by the wave vector of the incident field, the duration of signal and the acceleration of scatterers in the case of low flow velocities. In the opposite case geometrical properties of probing field and the average velocity itself are more essential. In the sense of signal-noise ratio, the optimal duration of time window can be found. Abovementioned results may contribute to the improved techniques of Doppler ultrasound diagnostics of cardiovascular system.

  16. Wave Tank Studies of Phase Velocities of Short Wind Waves

    Science.gov (United States)

    Ermakov, S.; Sergievskaya, I.; Shchegolkov, Yu.

    Wave tank studies of phase velocities of short wind waves have been carried out using Ka-band radar and an Optical Spectrum Analyser. The phase velocities were retrieved from measured radar and optical Doppler shifts, taking into account measurements of surface drift velocities. The dispersion relationship was studied in centimetre (cm)- and millimetre(mm)-scale wavelength ranges at different fetches and wind speeds, both for a clean water surface and for water covered with surfactant films. It is ob- tained that the phase velocities do not follow the dispersion relation of linear capillary- gravity waves, increasing with fetch and, therefore, depending on phase velocities of dominant decimetre (dm)-centimetre-scale wind waves. One thus can conclude that nonlinear cm-mm-scale harmonics bound to the dominant wind waves and propagat- ing with the phase velocities of the decimetric waves are present in the wind wave spectrum. The resulting phase velocities of short wind waves are determined by re- lation between free and bound waves. The relative intensity of the bound waves in the spectrum of short wind waves is estimated. It is shown that this relation depends strongly on the surfactant concentration, because the damping effect due to films is different for free and bound waves; this results to changes of phase velocities of wind waves in the presence of surfactant films. This work was supported by MOD, UK via DERA Winfrith (Project ISTC 1774P) and by RFBR (Project 02-05-65102).

  17. A micro-Doppler sonar for acoustic surveillance in sensor networks

    Science.gov (United States)

    Zhang, Zhaonian

    Wireless sensor networks have been employed in a wide variety of applications, despite the limited energy and communication resources at each sensor node. Low power custom VLSI chips implementing passive acoustic sensing algorithms have been successfully integrated into an acoustic surveillance unit and demonstrated for detection and location of sound sources. In this dissertation, I explore active and passive acoustic sensing techniques, signal processing and classification algorithms for detection and classification in a multinodal sensor network environment. I will present the design and characterization of a continuous-wave micro-Doppler sonar to image objects with articulated moving components. As an example application for this system, we use it to image gaits of humans and four-legged animals. I will present the micro-Doppler gait signatures of a walking person, a dog and a horse. I will discuss the resolution and range of this micro-Doppler sonar and use experimental results to support the theoretical analyses. In order to reduce the data rate and make the system amenable to wireless sensor networks, I will present a second micro-Doppler sonar that uses bandpass sampling for data acquisition. Speech recognition algorithms are explored for biometric identifications from one's gait, and I will present and compare the classification performance of the two systems. The acoustic micro-Doppler sonar design and biometric identification results are the first in the field as the previous work used either video camera or microwave technology. I will also review bearing estimation algorithms and present results of applying these algorithms for bearing estimation and tracking of moving vehicles. Another major source of the power consumption at each sensor node is the wireless interface. To address the need of low power communications in a wireless sensor network, I will also discuss the design and implementation of ultra wideband transmitters in a three dimensional

  18. Detection of Early Right Ventricular Dysfunction in Young Patients With Thalassemia Major Using Tissue Doppler Imaging

    Science.gov (United States)

    Bornaun, Helen; Dedeoglu, Reyhan; Oztarhan, Kazim; Dedeoglu, Savas; Erfidan, Erkan; Gundogdu, Muge; Aydogan, Gonul; Cengiz, Dicle

    2016-01-01

    Background Myocardial iron overload is the most common cause of mortality in patients with thalassemia major (TM), also known as beta-thalassemia. T2* cardiovascular magnetic resonance imaging (MRI) is the best way of monitoring cardiac iron, and new echocardiographic techniques can be used to assess cardiac function. Objectives The aim of this study was to assess the systolic and diastolic right ventricular (RV) function of patients with TM using tissue Doppler imaging (TDI) and to determine whether this echocardiographic technique is an adequate diagnostic tool for the screening and detection of subclinical cardiac dysfunction. Patients and Methods Eighty-four patients with TM were evaluated by conventional echocardiography and pulse-wave TDI. The data of the TM group (Group 1) were compared with that of 85 age- and sex-matched healthy controls (Group 2). Cardiovascular T2* MRI examinations were performed in 49 of the 85 patients. Results The patients with TM had significantly lower values for weight, height, body mass index, systolic arterial pressure, deceleration time, E’/A’, and ejection time (ET) than the controls. Group 1 also had significantly higher values for peak early diastolic velocity (E) over peak late diastolic velocity (A), peak early diastolic velocity of TDI (E’), peak late diastolic velocity of TDI (A’), E/E’, isovolumetric relaxation time, isovolumetric contraction time, and RV magnetic perfusion imaging (MPI) than Group 2. Conclusions RV diastolic dysfunction occurs before systolic deterioration in patients with TM and cannot be screened with conventional echocardiographic techniques. In routine practice, TDI measurements, MPI (for global function) and the E/E’ parameter (for diastolic function) can be used to screen and detect early RV dysfunction. PMID:27617076

  19. Strain Echocardiography Improves Risk Prediction of Ventricular Arrhythmias After Myocardial Infarction

    DEFF Research Database (Denmark)

    Haugaa, Kristina H; Grenne, Bjørnar L; Eek, Christian H

    2013-01-01

    The aim of this study was to test the hypothesis that strain echocardiography might improve arrhythmic risk stratification in patients after myocardial infarction (MI).......The aim of this study was to test the hypothesis that strain echocardiography might improve arrhythmic risk stratification in patients after myocardial infarction (MI)....

  20. Doppler ultrasound monitoring technology.

    Science.gov (United States)

    Docker, M F

    1993-03-01

    Developments in the signal processing of Doppler ultrasound used for the detection of fetal heart rate (FHR) have improved the operation of cardiotocographs. These developments are reviewed and the advantages and disadvantages of the various Doppler and signal processing methods are compared.

  1. Differential doppler heterodyning technique

    DEFF Research Database (Denmark)

    Lading, Lars

    1971-01-01

    Measuring velocity without disturbing the moving object is possible by use of the laser doppler heterodyning technique. Theoretical considerations on the doppler shift show that the antenna property of the photodetector can solve an apparent conflict between two different ways of calculating...

  2. Exercise echocardiography for structural heart disease.

    Science.gov (United States)

    Izumo, Masaki; Akashi, Yoshihiro J

    2016-03-01

    Since the introduction of transcatheter structural heart intervention, the term "structural heart disease" has been widely used in the field of cardiology. Structural heart disease refers to congenital heart disease, valvular heart disease, and cardiomyopathy. In structural heart disease, valvular heart disease is frequently identified in the elderly. Of note, the number of patients who suffer from aortic stenosis (AS) and mitral regurgitation (MR) is increasing in developed countries because of the aging of the populations. Transcatheter aortic valve replacement and percutaneous mitral valve repair has been widely used for AS and MR, individually. Echocardiography is the gold standard modality for initial diagnosis and subsequent evaluation of AS and MR, although the difficulties in assessing patients with these diseases still remain. Here, we review the clinical usefulness and prognostic impact of exercise echocardiography on structural heart disease, particularly on AS and MR.

  3. The Diagnostic Value of Pulsed Wave Tissue Doppler Imaging in Asymptomatic Beta- Thalassemia Major Children and Young Adults; Relation to Chemical Biomarkers of Left Ventricular Function and Iron Overload.

    Science.gov (United States)

    Ragab, Seham M; Fathy, Waleed M; El-Aziz, Walaa FAbd; Helal, Rasha T

    2015-01-01

    Cardiac iron toxicity is the leading cause of death among β-halassaemia major (TM) patients. Once heart failure becomes overt, it is difficult to reverse. To investigate non-overt cardiac dysfunctions in TM patients using pulsed wave Tissue Doppler Imaging (TD I) and its relation to iron overload and brain natriuretic peptide (BNP). Thorough clinical, conventional echo and pulsed wave TDI parameters were compared between asymptomatic 25 β-TM patients and 20 age and gender matched individuals. Serum ferritin and plasma BNP levels were assayed by ELISA. TM patients had significant higher mitral inflow early diastolic (E) wave and non significant other conventional echo parameters. In the patient group, pulsed wave TDI revealed systolic dysfunctions, in the form of significant higher isovolumetric contraction time (ICT), and lower ejection time (E T), with diastolic dysfunction in the form of higher isovolumetric relaxation time (IRT), and lower mitral annulus early diastolic velocity E' (12.07 ±2.06 vs 15.04±2.65, P= 0.003) compared to the controls. Plasma BNP was higher in patients compared to the controls. Plasma BNP and serum ferritin had a significant correlation with each other and with pulsed wave conventional and TDI indices of systolic and diastolic functions. Patients with E/E' ≥ 8 had significant higher serum ferritin and plasma BNP levels compared to those with ratio wave TDI is an important diagnostic tool for latent cardiac dysfunction in iron-loaded TM patients and is related to iron overload and BNP.

  4. Burst Format Design for Optimum Joint Estimation of Doppler-Shift and Doppler-Rate in Packet Satellite Communications

    Directory of Open Access Journals (Sweden)

    Luca Giugno

    2007-05-01

    Full Text Available This paper considers the problem of optimizing the burst format of packet transmission to perform enhanced-accuracy estimation of Doppler-shift and Doppler-rate of the carrier of the received signal, due to relative motion between the transmitter and the receiver. Two novel burst formats that minimize the Doppler-shift and the Doppler-rate Cramér-Rao bounds (CRBs for the joint estimation of carrier phase/Doppler-shift and of the Doppler-rate are derived, and a data-aided (DA estimation algorithm suitable for each optimal burst format is presented. Performance of the newly derived estimators is evaluated by analysis and by simulation, showing that such algorithms attain their relevant CRBs with very low complexity, so that they can be directly embedded into new-generation digital modems for satellite communications at low SNR.

  5. Multidetector CT evaluation of total anomalous pulmonary venous connections: comparison with echocardiography

    International Nuclear Information System (INIS)

    Oh, Ki Ho; Choo, Ki Seok; Lim, Soo Jin; Lee, Hyoung Doo; Park, Ji Ae; Jo, Min Jung; Sung, Si Chan; Chang, Yun Hee; Jeong, Dong Wook; Kim, Siho

    2009-01-01

    Although echocardiography is the first-line imaging modality in the diagnosis of total anomalous pulmonary venous connection (TAPVC), multidetector CT (MDCT) could have advantages in the diagnosis of TAPVC in certain cases. To compare MDCT with echocardiography in the evaluation of TAPVC. Enrolled in the study were 23 patients with surgically proven TAPVC. The echocardiography and MDCT findings were independently interpreted by a paediatric cardiologist and cardiac radiologist in terms of: (1) the drainage site of the common pulmonary vein, (2) stenosis of the vertical vein, and (3) the course of the atypical vessel into the systemic vein in the case of vertical vein stenosis. The findings from both modalities were correlated with the results obtained at surgery (n=22) or autopsy (n=1). In all patients, MDCT correctly depicted the drainage site of the common pulmonary vein, stenosis of the vertical vein and the course of the atypical vessel into the systemic vein (sensitivity 100%, specificity 100%). The specificity of echocardiography was 100% for the three defined findings. The sensitivity of echocardiography, however, was 87%, 71% and 0%, respectively. MDCT can facilitate the diagnosis of TAPVC in certain cases. (orig.)

  6. Time properties of ionospheric wave disturbances

    International Nuclear Information System (INIS)

    Kaliev, M.Z.; Krasnikov, I.M.; Litvinov, Yu.G.; Chakenov, B.D.; Yakovets, A.F.

    1989-01-01

    Records of Doppler frequency shifts of an ionospheric signal, taken in separate observation posts in the vicinity of Alma-Ata in 1986-1987, are analyzed. It is shown that the coherent parts of Doppler shift oscillations are wave disturbance trains in the ionospheric F region. The relation between the train duration and its central frequency is established. With the frequency decrease the mean train length increases, while the maximum train length, determined in the experiment, is about 6h. The probabilities of train detection in the low and high-frequency ranges are nearly the same, and moreover, they are equal in day time and at night

  7. Chaos weak signal detecting algorithm and its application in the ultrasonic Doppler bloodstream speed measuring

    International Nuclear Information System (INIS)

    Chen, H Y; Lv, J T; Zhang, S Q; Zhang, L G; Li, J

    2005-01-01

    At the present time, the ultrasonic Doppler measuring means has been extensively used in the human body's bloodstream speed measuring. The ultrasonic Doppler measuring means can achieve the measuring of liquid flux by detecting Doppler frequency shift of ultrasonic in the process of liquid spread. However, the detected sound wave is a weak signal that is flooded in the strong noise signal. The traditional measuring method depends on signal-to-noise ratio. Under the very low signal-to-noise ratio or the strong noise signal background, the signal frequency is not measured. This article studied on chaotic movement of Duffing oscillator and intermittent chaotic characteristic on chaotic oscillator of Duffing equation. In the light of the range of the bloodstream speed of human body and the principle of Doppler shift, the paper determines the frequency shift range. An oscillator array including many oscillators is designed according to it. The reflected ultrasonic frequency information can be ascertained accurately by the intermittent chaos quality of the oscillator. The signal-to-noise ratio of -26.5 dB is obtained by the result of the experiment. Compared with the tradition the frequency method compare, the dependence to signal-to-noise ratio is lowered consumedly. The measuring precision of the bloodstream speed is heightened

  8. [Real time 3D echocardiography

    Science.gov (United States)

    Bauer, F.; Shiota, T.; Thomas, J. D.

    2001-01-01

    Three-dimensional representation of the heart is an old concern. Usually, 3D reconstruction of the cardiac mass is made by successive acquisition of 2D sections, the spatial localisation and orientation of which require complex guiding systems. More recently, the concept of volumetric acquisition has been introduced. A matricial emitter-receiver probe complex with parallel data processing provides instantaneous of a pyramidal 64 degrees x 64 degrees volume. The image is restituted in real time and is composed of 3 planes (planes B and C) which can be displaced in all spatial directions at any time during acquisition. The flexibility of this system of acquisition allows volume and mass measurement with greater accuracy and reproducibility, limiting inter-observer variability. Free navigation of the planes of investigation allows reconstruction for qualitative and quantitative analysis of valvular heart disease and other pathologies. Although real time 3D echocardiography is ready for clinical usage, some improvements are still necessary to improve its conviviality. Then real time 3D echocardiography could be the essential tool for understanding, diagnosis and management of patients.

  9. Standard echocardiography versus handheld echocardiography for the detection of subclinical rheumatic heart disease: protocol for a systematic review.

    Science.gov (United States)

    Telford, Lisa H; Abdullahi, Leila H; Ochodo, Eleanor A; Zühlke, Liesl J; Engel, Mark E

    2018-02-10

    Rheumatic heart disease (RHD) is a preventable and treatable chronic condition which persists in many developing countries largely affecting impoverished populations. Handheld echocardiography presents an opportunity to address the need for more cost-effective methods of diagnosing RHD in developing countries, where the disease continues to carry high rates of morbidity and mortality. Preliminary studies have demonstrated moderate sensitivity as well as high specificity and diagnostic odds for detecting RHD in asymptomatic patients. We describe a protocol for a systematic review on the diagnostic performance of handheld echocardiography compared to standard echocardiography using the 2012 World Heart Federation criteria for diagnosing subclinical RHD. Electronic databases including PubMed, Scopus, Web of Science and EBSCOhost as well as reference lists and citations of relevant articles will be searched from 2012 to date using a predefined strategy incorporating a combination of Medical Subject Heading terms and keywords. The methodological validity and quality of studies deemed eligible for inclusion will be assessed against review specific Quality Assessment of Diagnostic Accuracy Studies 2 criteria and information on metrics of diagnostic accuracy and demographics extracted. Forest plots of sensitivity and specificity as well as scatter plots in receiver operating characteristic (ROC) space will be used to investigate heterogeneity. If possible, a meta-analysis will be conducted to produce summary results of sensitivity and specificity using the Hierarchical Summary ROC method. In addition, a sensitivity analysis will be conducted to investigate the effect of studies with a high risk of bias. Ethics approval is not required for this systematic review of previously published literature. The planned review will provide a summary of the diagnostic accuracy of handheld echocardiography. Results may feed into evidence-based guidelines and should the findings of this

  10. High-resolution velocimetry in energetic tidal currents using a convergent-beam acoustic Doppler profiler

    Science.gov (United States)

    Sellar, Brian; Harding, Samuel; Richmond, Marshall

    2015-08-01

    An array of single-beam acoustic Doppler profilers has been developed for the high resolution measurement of three-dimensional tidal flow velocities and subsequently tested in an energetic tidal site. This configuration has been developed to increase spatial resolution of velocity measurements in comparison to conventional acoustic Doppler profilers (ADPs) which characteristically use divergent acoustic beams emanating from a single instrument. This is achieved using geometrically convergent acoustic beams creating a sample volume at the focal point of 0.03 m3. Away from the focal point, the array is also able to simultaneously reconstruct three-dimensional velocity components in a profile throughout the water column, and is referred to herein as a convergent-beam acoustic Doppler profiler (C-ADP). Mid-depth profiling is achieved through integration of the sensor platform with the operational commercial-scale Alstom 1 MW DeepGen-IV Tidal Turbine deployed at the European Marine Energy Center, Orkney Isles, UK. This proof-of-concept paper outlines the C-ADP system configuration and comparison to measurements provided by co-installed reference instrumentation. Comparison of C-ADP to standard divergent ADP (D-ADP) velocity measurements reveals a mean difference of 8 mm s-1, standard deviation of 18 mm s-1, and an order of magnitude reduction in realisable length scale. C-ADP focal point measurements compared to a proximal single-beam reference show peak cross-correlation coefficient of 0.96 over 4.0 s averaging period and a 47% reduction in Doppler noise. The dual functionality of the C-ADP as a profiling instrument with a high resolution focal point make this configuration a unique and valuable advancement in underwater velocimetry enabling improved quantification of flow turbulence. Since waves are simultaneously measured via profiled velocities, pressure measurements and surface detection, it is expected that derivatives of this system will be a powerful tool in

  11. Pilot Study: Estimation of Stroke Volume and Cardiac Output from Pulse Wave Velocity.

    Directory of Open Access Journals (Sweden)

    Yurie Obata

    Full Text Available Transesophageal echocardiography (TEE is increasingly replacing thermodilution pulmonary artery catheters to assess hemodynamics in patients at high risk for cardiovascular morbidity. However, one of the drawbacks of TEE compared to pulmonary artery catheters is the inability to measure real time stroke volume (SV and cardiac output (CO continuously. The aim of the present proof of concept study was to validate a novel method of SV estimation, based on pulse wave velocity (PWV in patients undergoing cardiac surgery.This is a retrospective observational study. We measured pulse transit time by superimposing the radial arterial waveform onto the continuous wave Doppler waveform of the left ventricular outflow tract, and calculated SV (SVPWV using the transformed Bramwell-Hill equation. The SV measured by TEE (SVTEE was used as a reference.A total of 190 paired SV were measured from 28 patients. A strong correlation was observed between SVPWV and SVTEE with the coefficient of determination (R2 of 0.71. A mean difference between the two (bias was 3.70 ml with the limits of agreement ranging from -20.33 to 27.73 ml and a percentage error of 27.4% based on a Bland-Altman analysis. The concordance rate of two methods was 85.0% based on a four-quadrant plot. The angular concordance rate was 85.9% with radial limits of agreement (the radial sector that contained 95% of the data points of ± 41.5 degrees based on a polar plot.PWV based SV estimation yields reasonable agreement with SV measured by TEE. Further studies are required to assess its utility in different clinical situations.

  12. Doppler tomography in fusion plasmas and astrophysics

    DEFF Research Database (Denmark)

    Salewski, Mirko; Geiger, B.; Heidbrink, W. W.

    2015-01-01

    Doppler tomography is a well-known method in astrophysics to image the accretion flow, often in the shape of thin discs, in compact binary stars. As accretion discs rotate, all emitted line radiation is Doppler-shifted. In fast-ion Dα (FIDA) spectroscopy measurements in magnetically confined plasma......, the Dα-photons are likewise Doppler-shifted ultimately due to gyration of the fast ions. In either case, spectra of Doppler-shifted line emission are sensitive to the velocity distribution of the emitters. Astrophysical Doppler tomography has lead to images of accretion discs of binaries revealing bright...... and limits, analogies and differences in astrophysical and fusion plasma Doppler tomography and what can be learned by comparison of these applications....

  13. Understanding the Doppler effect by analysing spectrograms of the sound of a passing vehicle

    Science.gov (United States)

    Lubyako, Dmitry; Martinez-Piedra, Gordon; Ushenin, Arthur; Denvir, Patrick; Dunlop, John; Hall, Alex; Le Roux, Gus; van Someren, Laurence; Weinberger, Harvey

    2017-11-01

    The purpose of this paper is to demonstrate how the Doppler effect can be analysed to deduce information about a moving source of sound waves. Specifically, we find the speed of a car and the distance of its closest approach to an observer using sound recordings from smartphones. A key focus of this paper is how this can be achieved in a classroom, both theoretically and experimentally, to deepen students’ understanding of the Doppler effect. Included are our own experimental data (48 sound recordings) to allow others to reproduce the analysis, if they cannot repeat the whole experiment themselves. In addition to its educational purpose, this paper examines the percentage errors in our results. This enabled us to determine sources of error, allowing those conducting similar future investigations to optimize their accuracy.

  14. The Role of Echocardiography in Coronary Artery Disease and Acute Myocardial Infarction

    Science.gov (United States)

    Esmaeilzadeh, Maryam; Parsaee, Mozhgan; Maleki, Majid

    2013-01-01

    Echocardiography is a non-invasive diagnostic technique which provides information regarding cardiac function and hemodynamics. It is the most frequently used cardiovascular diagnostic test after electrocardiography and chest X-ray. However, in a patient with acute chest pain, Transthoracic Echocardiography is essential both for diagnosing acute coronary syndrome, zeroing on the evaluation of ventricular function and the presence of regional wall motion abnormalities, and for ruling out other etiologies of acute chest pain or dyspnea, including aortic dissection and pericardial effusion. Echocardiography is a versatile imaging modality for the management of patients with chest pain and assessment of left ventricular systolic function, diastolic function, and even myocardial and coronary perfusion and is, therefore, useful in the diagnosis and triage of patients with acute chest pain or dyspnea. This review has focused on the current applications of echocardiography in patients with coronary artery disease and myocardial infarction. PMID:23646042

  15. Effectiveness of simulator-based echocardiography training of noncardiologists in congenital heart diseases.

    Science.gov (United States)

    Wagner, Robert; Razek, Vit; Gräfe, Florentine; Berlage, Thomas; Janoušek, Jan; Daehnert, Ingo; Weidenbach, Michael

    2013-07-01

    Congenital heart diseases (CHD) are responsible for substantial morbidity and mortality in neonates. The preliminary diagnosis often is made by noncardiologists. For this reason, there is a huge demand of training in echocardiography of CHD. This is difficult to achieve due to limited resources of specialized centers. The goal of this study was to investigate the training effect of the echocardiography simulator EchoCom on trainee's ability to diagnose CHD. We enrolled 10 residents for simulator-based training in echocardiography of CHD. All participants were instructed on the simulator's basic handling and had one hour to scan the first 9 datasets information (ventricular septal defect, atrial septal defect, atrioventricular septal defect, Tetralogy of Fallot, transposition of great arteries, congenital corrected transposition of great arteries, common arterial trunk, hypoplastic left heart syndrome, normal anatomy) and establish a diagnosis. No help was given except for support regarding simulator related issues. Afterward, 2 rounds of structured simulator based echocardiography training focused on echocardiographic anatomy, spatial orientation, standard views, and echocardiographic anatomy of different CHD followed. All participants completed a standardized questionnaire containing 10 multiple-choice (MC) questions focusing on basic theoretical knowledge in echocardiographic anatomy and common CHD. Almost all of the residents invited from the affiliated children's hospital had little (20%) or no experience (80%) in echocardiography of CHD. Their Pretest and Posttest scores showed significant improvement for both, MC test and performance test, respectively. Our study showed that simulator-based training in echocardiography in CHD could be very effective and may assist with training outside the scope of CHD. © 2013, Wiley Periodicals, Inc.

  16. RECENT ADVANCES AND DIFFICULTIES OF INFRASONIC WAVE INVESTIGATION IN THE IONOSPHERE

    Czech Academy of Sciences Publication Activity Database

    Krasnov, Valerij Michailovič; Drobzheva, Yana Viktorovna; Laštovička, Jan

    2006-01-01

    Roč. 27, č. 2 (2006), s. 169-209 ISSN 0169-3298 R&D Projects: GA ČR GA205/04/2110 Institutional research plan: CEZ:AV0Z30420517 Keywords : acoustic wave * atmosphere * Doppler measurement * energy transfer * explosion monitoring * infrasonic sources * ionosphere * nonlinear effect * radio wave Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 1.452, year: 2006

  17. Dobutamine stress echocardiography in healthy adult male rats

    Directory of Open Access Journals (Sweden)

    Couet Jacques

    2005-10-01

    Full Text Available Abstract Background Dobutamine stress echocardiography is used to investigate a wide variety of heart diseases in humans. Dobutamine stress echocardiography has also been used in animal models of heart disease despite the facts that the normal response of healthy rat hearts to this type of pharmacological stress testing is unknown. This study was performed to assess this normal response. Methods 15 normal adult male Wistar rats were evaluated. Increasing doses of dobutamine were infused intravenously under continuous imaging of the heart by a 12 MHz ultrasound probe. Results Dobutamine stress echocardiography reduced gradually LV diastolic and systolic dimensions. Ejection fraction increased by a mean of +24% vs. baseline. Heart rate increased progressively without reaching a plateau. Changes in LV dimensions and ejection fraction reached a plateau after a mean of 4 minutes at a constant infusion rate. Conclusion DSE can be easily performed in rats. The normal response is an increase in heart rate and ejection fraction and a decrease in LV dimensions. A plateau in echocardiographic measurements is obtained after 4 minutes of a constant infusion rate in most animals.

  18. Predictors of transient left ventricular dysfunction following transcatheter patent ductus arteriosus closure in pediatric age.

    Science.gov (United States)

    Agha, Hala Mounir; Hamza, Hala S; Kotby, Alyaa; Ganzoury, Mona E L; Soliman, Nanies

    2017-10-01

    To evaluate the left ventricular function before and after transcatheter percutaneous patent ductus arteriosus (PDA) closure, and to identify the predictors of myocardial dysfunction post-PDA closure if present. Transcatheter PDA closure; conventional, Doppler, and tissue Doppler imaging; and speckle tracking echocardiography. To determine the feasibility and reliability of tissue Doppler and myocardial deformation imaging for evaluating myocardial function in children undergoing transcatheter PDA closure. Forty-two children diagnosed with hemodynamically significant PDA underwent percutaneous PDA closure. Conventional, Doppler, and tissue Doppler imaging, and speckle-derived strain rate echocardiography were performed at preclosure and at 48 hours, 1 month, and 6 months postclosure. Tissue Doppler velocities of the lateral and septal mitral valve annuli were obtained. Global and regional longitudinal peak systolic strain values were determined using two-dimensional speckle tracking echocardiography. The median age of the patients was 2 years and body weight was 15 kg, with the mean PDA diameter of 3.11 ± 0.99 mm. M-mode measurements (left ventricular end diastolic diameter, left atrium diameter to aortic annulus ratio, ejection fraction, and shortening fraction) reduced significantly early after PDA closure ( p  closure causes a significant decrease in left ventricular performance early after PDA closure, which recovers completely within 1 month. Preclosure global longitudinal strain can be a predictor of postclosure myocardial dysfunction.

  19. Evaluation of Computer-Based Training for Health Workers in Echocardiography for RHD.

    Science.gov (United States)

    Engelman, Daniel; Okello, Emmy; Beaton, Andrea; Selnow, Gary; Remenyi, Bo; Watson, Caroline; Longenecker, Chris T; Sable, Craig; Steer, Andrew C

    2017-03-01

    The implementation of screening for rheumatic heart disease at a population-scale would require a considerable increase in human resources. Training nonexpert staff in echocardiography requires appropriate methods and materials. This pre/post study aims to measure the change in the knowledge and confidence of a group of health workers after a computer-assisted training intervention in basic echocardiography for rheumatic heart disease. A syllabus of self-guided, computer-based modules to train nonexpert health workers in basic echocardiography for rheumatic heart disease was developed. Thirty-eight health workers from Uganda participated in the training. Using a pre/post design, identical test instruments were administered before and after the training intervention, assessing the knowledge (using multiple-choice questions) and confidence (using Likert scale questions) in clinical science and echocardiography. The mean total score on knowledge tests rose from 44.8% to 85.4% (mean difference: 40.6%, 95% confidence interval [CI]: 35.4% to 45.8%), with strong evidence for an increase in scores across all knowledge theme areas (p science (difference: 7.1, 95% CI: 6.2 to 8.0; p computer-assisted learning may reduce the human resource requirements for training staff in echocardiography. Copyright © 2016 World Heart Federation (Geneva). Published by Elsevier B.V. All rights reserved.

  20. Comparison of dipyridamole-echocardiography with dipyridamole-thallium scintigraphy for the diagnosis of myocardial ischemia

    International Nuclear Information System (INIS)

    Perin, E.C.; Moore, W.; Blume, M.; Hernandez, G.; Dhekne, R.; DeCastro, C.M.

    1991-01-01

    After an intravenous infusion of dipyridamole (0.56 mg/kg), the authors performed both echocardiography and thallium scintigraphy in 63 patients who were referred for known or suspected coronary artery disease. Of those patients, 25 returned for coronary arteriography within 1 month after the tests, thus forming the study group for this report. Sensitivity for detection of coronary artery disease, when analyzed region-by-region, was 80% for thallium scintigraphy and 57% for echocardiography, whereas specificity was 85% and 98%, respectively. When evaluating individual patients for the presence or absence of ischemia, they found a sensitivity of 95% for scintigraphy and 58% for echocardiography; corresponding specificities were 50% and 100%. By using arteriography as the gold standard for comparison, it appears that thallium scintigraphy has a significantly higher sensitivity but lower specificity for the detection of coronary artery disease than does echocardiography. Echocardiography may, however, be a useful adjunct to thallium scintigraphy in the evaluation of patients with coronary artery disease

  1. Diagnostic accuracy of electrocardiographic P wave related parameters in the assessment of left atrial size in dogs with degenerative mitral valve disease.

    Science.gov (United States)

    Soto-Bustos, Ángel; Caro-Vadillo, Alicia; Martínez-DE-Merlo, Elena; Alonso-Alegre, Elisa González

    2017-10-07

    The purpose of this research was to compare the accuracy of newly described P wave-related parameters (P wave area, Macruz index and mean electrical axis) with classical P wave-related parameters (voltage and duration of P wave) for the assessment of left atrial (LA) size in dogs with degenerative mitral valve disease. One hundred forty-six dogs (37 healthy control dogs and 109 dogs with degenerative mitral valve disease) were prospectively studied. Two-dimensional echocardiography examinations and a 6-lead ECG were performed prospectively in all dogs. Echocardiography parameters, including determination of the ratios LA diameter/aortic root diameter and LA area/aortic root area, were compared to P wave-related parameters: P wave area, Macruz index, mean electrical axis voltage and duration of P wave. The results showed that P wave-related parameters (classical and newly described) had low sensitivity (range=52.3 to 77%; median=60%) and low to moderate specificity (range=47.2 to 82.5%; median 56.3%) for the prediction of left atrial enlargement. The areas under the curve of P wave-related parameters were moderate to low due to poor sensitivity. In conclusion, newly P wave-related parameters do not increase the diagnostic capacity of ECG as a predictor of left atrial enlargement in dogs with degenerative mitral valve disease.

  2. Application of Contrast Echocardiography in Invasive Cardiology

    Directory of Open Access Journals (Sweden)

    Mustafa Bulut

    2010-12-01

    Full Text Available Contrast echocardiography by rendering better imaging of the borders of cardiac chambers is a useful tool for evaluating cardiac function, mass, myocardial vascularization, microvascular structure (small vessel vasculature and viability. Contrast was first started to be used for patients with suboptimal image quality. It can be used in detecting defects in myocardial blood supply in patients with chest pain and determining the success of interventionalprocedures. It can also be of help in demonstrating myocardial viability after reperfusion treatment in patients who had myocardial infarction. It is expected to be used more widely in invasive cardiology for decision making, guiding and determining the success of the procedures. Advances in imaging techniques , development of contrast materials for evaluation of left system, contrast echocardiography may become a routine clinical practice.

  3. Evaluation of Left Atrial Volumes Using Multidetector Computed Tomography: Comparison with Echocardiography

    International Nuclear Information System (INIS)

    Gweon, Hye Mi; Kim, Sang Jin; Kim, Tae Hoon; Lee, Sang Min; Hong, Yoo Jin; Rim, Se Joong

    2010-01-01

    To prospectively assess the relationship between the two different measurement methods for the evaluation of left atrial (LA) volume using cardiac multidetector computed tomography (MDCT) and to compare the results between cardiac MDCT and echocardiography. Thirty-five patients (20 men, 15 women; mean age, 60 years) underwent cardiac MDCT angiography for coronary artery disease. The LA volumes were measured using two different methods: the two dimensional (2D) length-based (LB) method measured along the three-orthogonal planes of the LA and the 3D volumetric threshold-based (VTB) method measured according to the threshold 3D segmentation of the LA. The results obtained by cardiac MDCT were compared with those obtained by echocardiography. The LA end-systolic and end-diastolic volumes (LAESV and LAEDV) measured by the 2D-LB method correlated well with those measured by the 3DVTB method using cardiac MDCT (r = 0.763, r = 0.786, p = 0.001). However, there was a significant difference in the LAESVs between the two measurement methods using cardiac MDCT (p < 0.05). The LAESV measured by cardiac MDCT correlated well with measurements by echocardiography (r = 0.864, p = 0.001), however with a significant difference (p < 0.01) in their volumes. The cardiac MDCT overestimated the LAESV by 22% compared to measurements by echocardiography. A significant correlation was found between the two different measurement methods for evaluating LA volumes by cardiac MDCT. Further, cardiac MDCT correlates well with echocardiography in evaluating the LA volume. However, there are significant differences in the LAESV between the two measurement methods using cardiac MDCT and between cardiac MDCT and echocardiography

  4. Detection of a stochastic background of gravitational radiation by the Doppler tracking of spacecraft

    International Nuclear Information System (INIS)

    Mashhoon, B.; Grishchuk, L.P.

    1980-01-01

    The possibility of detection of an isotropic background gravitational radiation of a stochastic nature by the method of Doppler tracking of spacecraft is considered. In the geometrical optics limit, the general formula for the frequency shift of an electromagnetic signal in the gravitational radiation field is discussed, and it is shown to be gauge (or rather Lie) independent. A detailed examination of the propagation of a free electromagnetic wave in a gravitational radiation field shows that no resonance phenomena can be expected. Thus, the results valid in the geometrical optics limit are also approximately valid for any gravitational radiation spectrum dominated by wavelengths large compared to that of the electromagnetic signal. The ''Doppler noise'' due to a stochastic background is evaluated, and it is shown to depend on the total energy density of the background and a parameter that is a characteristic of the aradiation spectrum and the detection system used. A background gravitational radiation with an energy density comparable to the electromagnetic (approx.3 K) background and a spectrum dominated by wavelengths > or approx. =1 AU may be detectable in the near future by the Doppler tracking of interplanetary spacecraft

  5. Color doppler imaging of subclavian steal phenomenon

    International Nuclear Information System (INIS)

    Cho, Nari Ya; Chung, Tae Sub; Kim, Jai Keun

    1997-01-01

    To evaluate the characteristic color doppler imaging of vertebral artery flow in the subclavian steal phenomenon. The study group consisted of eight patients with reversed vertebral artery flow proved by color Doppler imaging. We classified this flow into two groups:(1) complete reversal;(2) partial reversal, as shown by Doppler velocity waveform. Vertebral angiography was performed in six of eight patients;color Doppler imaging and angiographic findings were compared. On color Doppler imaging, all eight cases with reversed vertebral artery flow showed no signal at the proximal subclavian or brachiocephalic artery. We confirmed shunting of six cases by performing angiography from the contralateral vertebral and basilar artery to the ipsilateral vertebral artery. On the Doppler spectrum, six cases showed complete reversal and two partial reversal. On angiography, one partial reversal case showed complete occlusion of the subclavian artery with abundant collateral circulation of muscular branches of the vertebral artery. On color Doppler imaging, a reversed vertebral artery suggests the subclavian steal phenomenon. In particular, partial reversal waveform may reflect collateral circulation

  6. Radar micro-doppler signatures processing and applications

    CERN Document Server

    Chen, Victor C; Miceli, William J

    2014-01-01

    Radar Micro-Doppler Signatures: Processing and applications concentrates on the processing and application of radar micro-Doppler signatures in real world situations, providing readers with a good working knowledge on a variety of applications of radar micro-Doppler signatures.

  7. Audit of cardiac pathology detection using a criteria-based perioperative echocardiography service.

    Science.gov (United States)

    Faris, J G; Hartley, K; Fuller, C M; Langston, R B; Royse, C F; Veltman, M G

    2012-07-01

    Transthoracic echocardiography is often used to screen patients prior to non-cardiac surgery to detect conditions associated with perioperative haemodynamic compromise and to stratify risk. However, anaesthetists' use of echocardiography is quite variable. A consortium led by the American College of Cardiology Foundation has developed appropriate use criteria for echocardiography. At Joondalup Hospital in Western Australia, we have used these criteria to order echocardiographic studies in patients attending our anaesthetic pre-admission clinic. We undertook this audit to determine the incidence of significant echocardiographic findings using this approach. In a 22-month period, 606 transthoracic echocardiographic studies were performed. This represented 8.7% of clinic attendees and 1.7% of all surgical patients. In about two-thirds of the patients, the indication for echocardiography was identified on the basis of a telephone screening questionnaire. The most common indications were poor exercise tolerance (27.4%), ischaemic heart disease (20.9%) and cardiac murmurs (16.3%). Over 26% of patients studied had significant cardiac pathology (i.e. moderate or severe echocardiographic findings), most importantly moderate or severe aortic stenosis (8.6%), poor left ventricular function (7.1%), a regional wall motion abnormality (4.3%) or moderate or severe mitral regurgitation (4.1%). Using appropriate use criteria to guide ordering transthoracic echocardiography studies led to a high detection rate of clinically important cardiac pathology in our perioperative service.

  8. Dynamic 3D echocardiography in virtual reality.

    NARCIS (Netherlands)

    A.E. van den Bosch (Annemien); A.H.J. Koning (Anton); F.J. Meijboom (Folkert); J.S. Vletter-McGhie (Jackie); M.L. Simoons (Maarten); P.J. van der Spek (Peter); A.J.J.C. Bogers (Ad)

    2005-01-01

    textabstractBACKGROUND: This pilot study was performed to evaluate whether virtual reality is applicable for three-dimensional echocardiography and if three-dimensional echocardiographic 'holograms' have the potential to become a clinically useful tool. METHODS: Three-dimensional echocardiographic

  9. Intra-cardiac echocardiography in alcohol septal ablation

    DEFF Research Database (Denmark)

    Cooper, Robert M; Shahzad, Adeel; Newton, James

    2015-01-01

    Alcohol septal ablation (ASA) in hypertrophic obstructive cardiomyopathy reduces left ventricular outflow tract gradients. A third of patients do not respond; inaccurate localisation of the iatrogenic infarct can be responsible. Transthoracic echocardiography (TTE) using myocardial contrast can...

  10. [Doppler ultrasound evaluation of aortic insufficiency using half-pressure time. Absence of arterial rigidity influence].

    Science.gov (United States)

    Kalotka-Bratek, H; Drobinski, G; Klimczak, K; Busquet, P; Fraysse, J B; Bejean-Lebuisson, A; Grosgogeat, Y

    1989-02-01

    In 20 patients with pure aortic regurgitation we studied the relationship between the severity of regurgitation, as assessed haemodynamically by the percentage of leakage (%L), and the half-pressure (T 1/2 P) and half-velocity (T 1/2 V) times, as obtained from doppler aortic blood velocity curves, taking into account the rigidity of the systemic vascular circuit characterized by the pressure wave propagation velocity (PWPV). The systemic arterial circuit was supple in 14 patients (PWPV less than 7.5 m/sec) and rigid in 6 patients (PWPV greater than 7.5 m/sec). The regression slopes between %L and T 1/2 P and between %L and T 1/2 V were calculated with their confidence limits in the 14 patients with supple arteries. The 6 patients with rigid arteries fitted into this nomogram, thus demonstrating that systemic arterial rigidity makes no difference in the relationship between %L and doppler indices. The half-velocity and half-pressure times measured by doppler ultrasound were acquired from a velocity signal directly determined by the aortic regurgitation, without any detectable effect of vascular circuit rigidity. Being equivalent by nature to the signal decrease time constant, they are independent of the absolute protodiastolic value of diastolic pressure gradient or blood flow velocity. For this reason these two doppler parameters are reliable to evaluate the severity of aortic regurgitation.

  11. Observational Signatures of Transverse Magnetohydrodynamic Waves and Associated Dynamic Instabilities in Coronal Flux Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Antolin, P.; Moortel, I. De [School of Mathematics and Statistics, University of St. Andrews, St. Andrews, Fife KY16 9SS (United Kingdom); Doorsselaere, T. Van [Centre for mathematical Plasma Astrophysics, Mathematics Department, KU Leuven, Celestijnenlaan 200B bus 2400, B-3001 Leuven (Belgium); Yokoyama, T., E-mail: patrick.antolin@st-andrews.ac.uk [Department of Earth and Planetary Science, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan)

    2017-02-20

    Magnetohydrodynamic (MHD) waves permeate the solar atmosphere and constitute potential coronal heating agents. Yet, the waves detected so far may be but a small subset of the true existing wave power. Detection is limited by instrumental constraints but also by wave processes that localize the wave power in undetectable spatial scales. In this study, we conduct 3D MHD simulations and forward modeling of standing transverse MHD waves in coronal loops with uniform and non-uniform temperature variation in the perpendicular cross-section. The observed signatures are largely dominated by the combination of the Kelvin–Helmholtz instability (KHI), resonant absorption, and phase mixing. In the presence of a cross-loop temperature gradient, we find that emission lines sensitive to the loop core catch different signatures compared to those that are more sensitive to the loop boundary and the surrounding corona, leading to an out-of-phase intensity and Doppler velocity modulation produced by KHI mixing. In all of the considered models, common signatures include an intensity and loop width modulation at half the kink period, a fine strand-like structure, a characteristic arrow-shaped structure in the Doppler maps, and overall line broadening in time but particularly at the loop edges. For our model, most of these features can be captured with a spatial resolution of 0.″33 and a spectral resolution of 25 km s{sup −1}, although we do obtain severe over-estimation of the line width. Resonant absorption leads to a significant decrease of the observed kinetic energy from Doppler motions over time, which is not recovered by a corresponding increase in the line width from phase mixing and KHI motions. We estimate this hidden wave energy to be a factor of 5–10 of the observed value.

  12. Field verification of ADCP surface gravity wave elevation spectra

    NARCIS (Netherlands)

    Hoitink, A.J.F.; Peters, H.C.; Schroevers, M.

    2007-01-01

    Acoustic Doppler current profilers (ADCPs) can measure orbital velocities induced by surface gravity waves, yet the ADCP estimates of these velocities are subject to a relatively high noise level. The present paper introduces a linear filtration technique to significantly reduce the influence of

  13. A follow-up study of neonatal interatrial shunt with echocardiography until twelve to fifteen months of age.

    Science.gov (United States)

    Ho, Chi-Lin; Jan, Sheng-Ling; Lin, Ming-Chih; Fu, Yun-Ching

    2008-12-01

    To assess the incidence and natural history of full-term neonates with interatrial shunt (IAS). A follow-up study of 1389 neonates who received screening echocardiography between 2003 and 2006. Babies with IAS at 2 to 4 days of life underwent follow-up echocardiography at 2 to 4 months, 6 to 9 months and 12 to 15 months of age until closure of IAS. The ratio of IAS was 68.3% initially. No significant demographic differences were identified between infants with and without initial IAS. Among 949 neonates with initial IAS, 84.5% infants had a left-to-right interatrial shunt, 13.5% had bidirectional shunt and 2% had predominantly right-to-left shunt. The persistence rate of IAS at 12 to 15 months of age was 3.8% (44/1166). The initial size of IAS ranged from 1.2 to 7.7mm (4.3+/-1.1 mm) detected by color Doppler flow mapping and cases were divided into three groups: small ( or =8 mm). There were 74.6% infants in the small group and 25.4% in the medium group initially. The neonates in the initial small group would always see their IAS close or else they would remain in the small group. Those in the final medium and large size groups always came from the initial medium group. The late closure rate of IAS was 93.9% of infants with initial IAS. The closure curves of initial small and medium sized groups were significantly different, and their late closure rates were 95.1% and 90.4%, respectively. IAS was very common during early neonatal stage, but most cases would close after 1 year. The late closure rate of initial IAS was different if using a cutpoint of 5 mm.

  14. Echocardiography for patent ductus arteriosus including closure in adults.

    Science.gov (United States)

    Chugh, Reema; Salem, Morris M

    2015-01-01

    Patent ductus arteriosus (PDA) represents at least 5-10% of all congenital heart defects (CHDs) making it a very important commonly diagnosed lesion. Although spontaneous closure of the PDA occurs within 24 to 48 hours after birth in the majority, those children who do not have natural or surgical closure may have a persistent PDA into adulthood. The diagnosis is most often confirmed by echocardiography that also guides catheter-based interventions and surgeries. Echocardiography continues to be the most important tool in long-term follow-up of residua and sequelae. © 2014, Wiley Periodicals, Inc.

  15. Color doppler sonography in thickened gallbladder wall

    International Nuclear Information System (INIS)

    Han, Sang Suk; Choi, Seok Jin; Seo, Chang Hae; Eun, Choong Ki

    1996-01-01

    The thickening of the gallbladder wall is a valuable finding for the diagnosis of cholecystitis, but may be seen in non-cholecystic disease as well as in acute or chronic cholecystitis. The purpose of this study is to determine the value of color Doppler sonography in differentiating the causes of thickened gallbladder wall. Ninety eight patients with thickened gallbladder wall(more than 3mm) which was not due to gallbladder cancer were prospectively evaluated with color Doppler sonography. Sixty-six cases, confirmed by pathologic reports and clinical records, were analyzed for correlation between thickened gallbladder wall and color flow signal according to the underlying causes. Of the 66 patients, 28 cases were cholecystitis and 38 cases had non-cholecystic causes such as liver cirrhosis, ascites, hepatitis, pancreatitis, renal failure, and hypoalbuminemia. Of the 28 patients with cholecystitis(12 acute, 16 chronic), 23(82%) had color Doppler flow signals in the thickened gallbladder wall. Of the 38 patients with non-cholecystic causes, eight(21%) had color Doppler flow signals. There was a statistically significant difference of color Doppler flow signals between the cholecystitis and non-cholecystic groups(p=0.0001). No significant difference of color Doppler flow signals was found between cases of acute and chronic cholecystitis. Of the 23 patients with color Doppler flow signals in 28 cases of cholecystitis, 18(78.3%) showed a linear pattern and five(21.7%) showed a spotty pattern. Of the eight patients with color Doppler flow signals in the 38 non-cholecystic cases, four(50%) showed a linear pattern and four(50%) showed a spotty pattern. In cholecystitis, a linear color Doppler flow signal pattern is a much more frequent finding than a spotty pattern. Color Doppler sonography is a useful and adequate method for determining whether a thickened gallbladder wall is the result of cholecystitis or has non-cholecystic causes

  16. Pulse Doppler radar

    CERN Document Server

    Alabaster, Clive

    2012-01-01

    This book is a practitioner's guide to all aspects of pulse Doppler radar. It concentrates on airborne military radar systems since they are the most used, most complex, and most interesting of the pulse Doppler radars; however, ground-based and non-military systems are also included. It covers the fundamental science, signal processing, hardware issues, systems design and case studies of typical systems. It will be a useful resource for engineers of all types (hardware, software and systems), academics, post-graduate students, scientists in radar and radar electronic warfare sectors and milit

  17. Nonlinear instability and chaos in plasma wave-wave interactions, I., Introduction

    International Nuclear Information System (INIS)

    Kueny, C.S.; Morrison, P.J.

    1994-11-01

    Conventional linear stability analyses may fail for fluid systems with an indefinite free energy functional. When such a system is linearly stable, it is said to possess negative energy modes. Instability may then occur either via dissipation of the negative energy modes, or nonlinearly via resonant wave-wave coupling, leading to explosive growth. In the dissipationless case, it is conjectured that intrinsic chaotic behavior may allow initially nonresonant systems to reach resonance by diffusion in phase space. In this and a companion paper [submitted to Physics of Plasmas], this phenomenon is demonstrated for a simple equilibrium involving cold counterstreaming ions. The system is described in the fluid approximation by a Hamiltonian functional and associated noncanonical Poisson bracket. By Fourier decomposition and appropriate coordinate transformations, the Hamiltonian for the perturbed energy is expressed in action-angle form. The normal modes correspond to Doppler-shifted ion-acoustic waves of positive and negative energy. Nonlinear coupling leads to decay instability via two-wave interactions, and to either decay or explosive instability via three-wave interactions. These instabilities are described for various (integrable) systems of waves interacting via single nonlinear terms. This discussion provides the foundation for the treatment of nonintegrable systems in the companion paper

  18. Nonlinear instability and chaos in plasma wave--wave interactions. I. Introduction

    International Nuclear Information System (INIS)

    Kueny, C.S.; Morrison, P.J.

    1995-01-01

    Conventional linear stability analyses may fail for fluid systems with an indefinite free-energy functional. When such a system is linearly stable, it is said to possess negative energy modes. Instability may then occur either via dissipation of the negative energy modes, or nonlinearly via resonant wave--wave coupling, leading to explosive growth. In the dissipationless case, it is conjectured that intrinsic chaotic behavior may allow initially nonresonant systems to reach resonance by diffusion in phase space. In this and a companion paper (submitted to Phys. Plasmas), this phenomenon is demonstrated for a simple equilibrium involving cold counterstreaming ions. The system is described in the fluid approximation by a Hamiltonian functional and associated noncanonical Poisson bracket. By Fourier decomposition and appropriate coordinate transformations, the Hamiltonian for the perturbed energy is expressed in action-angle form. The normal modes correspond to Doppler-shifted ion-acoustic waves of positive and negative energy. Nonlinear coupling leads to decay instability via two-wave interactions, and to either decay or explosive instability via three-wave interactions. These instabilities are described for various integrable systems of waves interacting via single nonlinear terms. This discussion provides the foundation for the treatment of nonintegrable systems in the companion paper. copyright 1995 American Institute of Physics

  19. Assessment of left ventricular wall motion and function by cross-sectional echocardiography

    International Nuclear Information System (INIS)

    Ono, Akifumi; Hirata, Shunkichi; Ishikawa, Kyozo

    1982-01-01

    The clinical efficacy of cross-sectional echocardiography (CSE) was evaluated with M-mode echocardiography and radionuclide cardioangiography (RCG) in 50 cases including 30 patients with myocardial infarction. Segmental wall motion by CSE was highly correlated with segmental wall motion and left ventricular ejection fraction by RCG (r = 0.89 in the former, r = -0.84 in the latter). On the other hand, the left ventricular ejection fraction by M-mode echocardiography revealed a fairly well correlation with that by RCG ( r = 0.68). These results suggest that, as compared with RCG, CSE is quite useful in an evaluation of left ventricular function and in a detection of segmental wall motion abnormalities. (author)

  20. Doppler Frequency Shift in Ocean Wave Measurements: Frequency Downshift of a Fixed Spectral Wave Number Component by Advection of Wave Orbital Velocity

    National Research Council Canada - National Science Library

    Hwang, Paul

    2006-01-01

    ... at he expected intrinsic frequency in the frequency spectrum measured by a stationary probe. The advection of the wave number component by the orbital current of background waves produces a net downshift in the encounter frequency...

  1. Highly Nonlinear Wave Propagation in Elastic Woodpile Periodic Structures

    Science.gov (United States)

    2016-08-03

    called a nanopteron, is not only motivated theoretically and numerically, but are also visualized experimentally by means of a laser Doppler vibrometer...velocity, which clearly follow the prin- cipal solitary wave (highlighted in red color ). It should be noted that the velocities involved in the

  2. Evaluation of left ventricular diastolic echocardiographic parameters in healthy dogs by pulsed-wave Doppler Avaliação de parâmetros ecocardiográficos diastólicos do ventrículo esquerdo de cães saudáveis por meio de Doppler pulsátil

    Directory of Open Access Journals (Sweden)

    Guilherme G. Pereira

    2009-04-01

    Full Text Available Left ventricular diastolic dysfunction plays an important role on heart failure progression. In order to obtain additional reference values of left ventricular diastolic parameters and investigate influence of common variables, peak E wave (peak E, peak A wave (peak A, E/A ratio (E/A, E wave deceleration time (EDT and isovolumic relaxation time (IRVT were studied in 40 clinically healthy dogs, by pulsed wave Doppler. The following values were obtained: peak E = 0.747 ± 0.117 m/s, peak A = 0.487 ± 0.062 m/s, E/A = 1.533 ± 0.198, EDT = 88.7 ± 9.2 ms and IRVT = 0.080 ± 0.009 s. Some parameters were influenced by heart rate (peak E, peak A and IRVT, by age (peak A and E/A and by body weight (TRIV. Gender influence was absent. Values obtained can be used as reference for canine specimens but its interpretation should consider on the influence of related variables.A disfunção diastólica do ventrículo esquerdo contribui de maneira importante para a progressão da insuficiência cardíaca. No intuito de obter valores de referência adicionais para os parâmetros diastólicos do ventrículo esquerdo e para investigar a influência de variáveis comuns, estudou-se, por meio de Doppler pulsátil, a velocidade máxima da onda E (Vmáx.E, a velocidade máxima da onda A (Vmáx.: A, a relação E/A (E/A, o tempo de desaceleração da onda E (TDE e o tempo de relaxamento isovolumétrico (TRIV em 40 cães clinicamente saudáveis. Os seguintes valores foram obtidos: Vmáx.E = 0,747±0,117m/s, Vmáx.A = 0,487±0,062m/s, E/A = 1,533±0,198, TDE = 88,7±9,2ms e TRIV = 0,080±0,009s. Alguns parâmetros foram influenciados pela freqüência cardíaca (Vmáx.E, Vmáx.A e TRIV, pela idade (Vmáx.A e E/A e pelo peso corpóreo (TRIV. Não houve influência pelo sexo. Os valores obtidos podem ser utilizados como referência para a espécie canina, porém devem ser interpretados considerando-se a influência das variáveis descritas.

  3. THE DIAGNOSTIC VALUE OF PULSED WAVE TISSUE DOPPLER IMAGING IN ASYMPTOMATIC BETA- THALASSEMIA MAJOR CHILDREN AND YOUNG ADULTS ; RELATION TO CHEMICAL BIOMARKERS OF LEFT VENTRICULAR FUNCTION AND IRON OVERLOAD .

    Directory of Open Access Journals (Sweden)

    Seham Ragab

    2015-08-01

    Full Text Available Background: Cardiac iron toxicity is the leading cause of death among  β-halassaemia major (TM  patients.  Once  heart failure becomes overt , it will be  difficult to reverse . Objectives: To investigate non overt cardiac dysfunctions  in TM patients using  pulsed wave Tissue Doppler  Imaging (TD I and its relation to the iron overload and brain natruritic peptide (BNP. Methods: Thorough  clinical , conventional echo and  pulsed  wave TDI  parameters were compared between  asymtomatic 25 β-TM  patients  and 20 age and gender matched individuals. Serum ferritin and plasma BNP  levels were assayed by  ELISA .  Results: TM patients had significant higher mitral inflow early diastolic (E wave and  non significant other conventional echo  parameters. Pulsed wave TDI revealed systolic and diastolic dysfunctions in the form of significant higher  isovolumetric contraction time (ICT , ejection time ( E T and  isovolumetric relaxation time (IRT with significantly lower  mitral annulus  early diastolic velocity E` (12.07 ±2.06 vs 15.04±2.65 ,P= 0.003  in patients compared to  controls. Plasma BNP was higher in patients compared to the controls.  Plasma BNP and serum ferritin had significant correlation with each other and with pulsed wave conventional and TDI indices of systolic and diastolic functions.  Patients with E/E` ≥ 8 had  significant higher  serum ferritin  and plasma BNP levels compared to those with E/E` ratio < 8 without difference in Hb levels .Conclusion:  Pulsed wave TDI  is an  important diagnostic tool for latent cardiac dysfunction in iron loaded TM patients and is related to iron overload and BNP .

  4. Comparison of exercise stress testing with dobutamine stress echocardiography and radionuclide ventriculography for diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Ozdemir, K.; Kisacik, H.L.; Oguzhan, A.

    1999-01-01

    Dobutamine stress echocardiography, Tc-99m radionuclide ventriculography (RNVG), and exercise stress testing were performed prospectively in 63 patients with suspected coronary artery disease to compare the values of exercise testing, dobutamine stress echocardiography and RNVG in the non-invasive diagnosis of coronary artery disease. The sensitivities of dobutamine stress echocardiography and RNVG were found to be higher than that of exercise testing (93-62%, p 0.05). There were no differences between the sensitivities of the three techniques in multiple vessel disease (p>0.05). The specificities of dobutamine stress echocardiography and RNVG were higher than that of exercise testing (for both of the tests 86-62%, p 0.05). The results of dobutamine stress echocardiography RNVG were concordant with each other in 46 patients (76%, kappa=65%) in sectional analysis. Dobutamine stress echocardiography and RNVG tests were comparable with each other in 85% of the 189 segments (kappa=64%). The expected 5% decrease at peak doses of dobutamine was not detected in stress echocardiography in 25 patients and in RNVG in 26 of the patients. Dobutamine stress echocardiography and RNVG are superior to exercise testing in the diagnosis of single vessel disease and there is no significant difference between the two techniques. When the ejection fraction is considered in dobutamine stress echocardiography and RNVG, it does not make an additional contribution to the diagnosis of coronary artery disease. (author)

  5. The Interplay between Fasting Glucose, Echocardiography, and Biomarkers

    DEFF Research Database (Denmark)

    Pareek, Manan

    preventive setting, remains incomplete. Phenotypical heterogeneity may be even greater among subjects with hyperglycemic conditions, i.e., prediabetes and diabetes, which is worrisome, given the dramatic global rise in mean fasting glucose levels, and the strong association with adverse cardiovascular...... subclinical changes to manifest disease include echocardiography and circulating biomarkers. Objectives 1) To examine whether greater fasting plasma glucose (FPG) levels were associated with left ventricular mass (LVM), geometric pattern, diastolic function, and concentrations of N-terminal prohormone...... from the three categories defined by baseline FPG, i.e., normal fasting glucose, impaired fasting glucose, and diabetes, including use of anti-diabetic medication. Blood samples for cardiovascular biomarker assessments were drawn at the time of echocardiography and kept frozen until analysis. Outcome...

  6. Contrast agents provide a faster learning curve in dipyridamole stress echocardiography.

    Science.gov (United States)

    Zamorano, Jose; Sánchez, Violeta; Moreno, Raúl; Almería, Carlos; Rodrigo, Jose; Serra, Viviana; Azcona, Luis; Aubele, Adalia; Mataix, Luis; Sánchez-Harguindey, Luis

    2002-12-01

    Interobserver variability is an important limitation of the stress echocardiography and depends on the echocardiographer training. Our aim was to evaluate if the use of contrast agents during dipyridamole stress echocardiography would improve the agreement between an experienced and a non-experienced observer in stress echo and therefore if contrast would affect the learning period of dypyridamole stress echo. Two independent observers without knowledge of any patient data interpreted all stress studies. One observer was an experienced one and the other had experience in echocardiography but not in stress echo. Two observers analysed 87 non-selected and consecutive studies. Out of the 87 studies, 46 were performed without contrast administration, whereas i.v. contrast (2.5 g Levovist by two bolus at rest and at peak stress) was administered in 41. In all cases, second harmonic imaging and stress digitalisation pack was used. The agreement between observers showed a kappa index of 0.58 and 0.83 without and with contrast administration, respectively. The use of contrast agents provides a better agreement in the evaluation of stress echo between an experienced and a non-experienced observer in stress echo. Adding routinely contrast agents could probably reduce the number of exams required for the necessary learning curve in stress echocardiography.

  7. Arterial wave reflection and aortic valve calcification in an elderly community-based cohort.

    Science.gov (United States)

    Sera, Fusako; Russo, Cesare; Iwata, Shinichi; Jin, Zhezhen; Rundek, Tatjana; Elkind, Mitchell S V; Homma, Shunichi; Sacco, Ralph L; Di Tullio, Marco R

    2015-04-01

    Aortic valve calcification (AVC) without stenosis is common in the elderly, is associated with cardiovascular morbidity and mortality, and may progress to aortic valve stenosis. Arterial stiffness and pulse-wave reflection are important components of proximal aortic hemodynamics, but their relationship with AVC is not established. To investigate the relationship of arterial wave reflection and stiffness with AVC, pulse wave analysis and AVC evaluation by echocardiography were performed in 867 participants from the Cardiovascular Abnormalities and Brain Lesions study. Participants were divided into four categories on the basis of the severity and extent of AVC: (1) none or mild focal AVC, (2) mild diffuse AVC, (3) moderate to severe focal AVC, and (4) moderate to severe diffuse AVC. Central blood pressures and pulse pressure, total arterial compliance, augmentation index, and time to wave reflection were assessed using applanation tonometry. Indicators of arterial stiffness and wave reflection were significantly associated with AVC severity, except for central systolic and diastolic pressures and time to reflection. After adjustment for pertinent covariates (age, sex, race/ethnicity, and estimated glomerular filtration rate), only augmentation pressure (P = .02) and augmentation index (P = .002) were associated with the severity of AVC. Multivariate logistic regression analysis revealed that augmentation pressure (odds ratio per mm Hg, 1.14; 95% confidence interval, 1.02-1.27; P = .02) and augmentation index (odds ratio per percentage point, 1.07; 95% confidence interval, 1.01-1.13; P = .02) were associated with an increased risk for moderate to severe diffuse AVC, even when central blood pressure value was included in the same model. Arterial wave reflection is associated with AVC severity, independent of blood pressure values. Increased contribution of wave reflection to central blood pressure could be involved in the process leading to AVC. Copyright © 2015

  8. Two dimensional and Doppler echocardiographic evaluation of patients presenting at Obafemi Awolowo University Teaching Hospitals Complex Ile Ife Nigeria a prospective study of 2501 subjects

    Directory of Open Access Journals (Sweden)

    Adebayo RA

    2013-07-01

    Full Text Available Rasaaq Ayodele Adebayo,1 Patience Olayinka Akinwusi,2 Michael Olabode Balogun,1 Anthony Olubunmi Akintomide,1 Victor Oladeji Adeyeye,1 Olugbenga Olusola Abiodun,1 Luqman Adeleke Bisiriyu,3 Suraj Adefabi Ogunyemi,1 Ebenezer Adekunle Ajayi,4 Olufemi Eyitayo Ajayi,1 Adebayo Tolulope Oyedeji5 1Cardiology Unit, Department of Medicine, Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife, Osun State, 2Cardiology Unit, Department of Medicine, Osun State University, Osogbo, Osun State, 3Department of Demography and Social Statistics, Obafemi Awolowo University, Ile-Ife, Osun State, 4Cardiology Unit, Department of Medicine, Ekiti State University Teaching Hospital, Ado-Ekiti, Ekiti State, 5Cardiology Unit, Department of Medicine, LAUTECH Teaching Hospital, Osogbo, Osun State, Nigeria Background: Echocardiography remains a key noninvasive cardiac investigative tool in the management of patients, especially in a developing economy like Nigeria. In this study, we investigated the indications for transthoracic echocardiography and spectrum of cardiac disease found in patients referred to our cardiac unit for echocardiography. Methods: A prospective two-dimensional, pulsed, continuous, and color-flow Doppler echocardiographic evaluation was done using the transthoracic approach in 2501 patients over an eight-year period. Univariate data analysis was performed for mean age, gender, clinical indications, and diagnoses. Results: The subject age range was less than 12 months to 97 years (mean 52.39 years. There were 1352 (54.06% males and 1149 (45.94% females. The most common indication for echocardiography was hypertension (52.1% followed by congestive cardiac failure (13.9%. Others were for screening (6.1%, arrhythmias (5%, cerebrovascular disease (5%, chest pain (3.3%, chronic kidney disease (3.2%, congenital heart disease (2.6%, cardiomyopathy (1.8%, rheumatic heart disease (1.7%, diabetes mellitus (1.3%, thyrocardiac disease (1.2%, ischemic heart

  9. Usefulness of three-dimensional echocardiography in the assessment of valvular involvement in Loeffler endocarditis.

    Science.gov (United States)

    Hernandez, Carlos M; Arisha, Mohammed J; Ahmad, Amier; Oates, Ethan; Nanda, Navin C; Nanda, Anil; Wasan, Anita; Caleti, Beda E; Bernal, Cinthia L P; Gallardo, Sergio M

    2017-07-01

    Loeffler endocarditis is a complication of hypereosinophilic syndrome resulting from eosinophilic infiltration of heart tissue. We report a case of Loeffler endocarditis in which three-dimensional transthoracic and transesophageal echocardiography provided additional information to what was found by two-dimensional transthoracic echocardiography alone. Our case illustrates the usefulness of combined two- and three-dimensional echocardiography in the assessment of Loeffler endocarditis. In addition, a summary of the features of hypereosinophilic syndrome and Loeffler endocarditis is provided in tabular form. © 2017, Wiley Periodicals, Inc.

  10. A clutter removal method for the Doppler ultrasound signal based on a nonlinear diffusion equation

    International Nuclear Information System (INIS)

    Li Peng; Xin Pengcheng; Bian Zhengzhong; Yu Gang

    2008-01-01

    Strong clutter components produced by stationary and slow-moving tissue structures render the lower frequency part of the spectrogram useless and degrade the accuracy of clinical ultrasound indices. An adaptive method based on the nonlinear forward-and-backward diffusion equation (FAB-DE) is proposed to remove strong clutter components from the contaminated Doppler signal. The clutter signal is extracted first by the FAB-DE accurately, in which the nonlinear diffusion coefficient function of the FAB-DE locally adjusts according to signal features and the diffusion adaptively switches between forward and backward mode. The present method has been validated by simulated and realistic pulse wave Doppler signals, and compared with the conventional high pass filter and the matching pursuit method. The simulation results, including spectrogram, mean velocity error, standard deviation of mean velocity and signal-to-clutter ratio of a decontaminated signal, demonstrate that the present FAB-DE method can remove clutter sufficiently and retain more low blood components simultaneously as compared with the other two methods. Results of the realistic Doppler blood signal, including spectrogram and low-frequency part of the spectrum, support the conclusion drawn from simulation cases

  11. Portopulmonary hypertension: Improved detection using CT and echocardiography in combination

    Energy Technology Data Exchange (ETDEWEB)

    Devaraj, Anand [Royal Brompton and Harefield NHS Foundation Trust, Department of Radiology, London (United Kingdom); Loveridge, Robert; Bernal, William; Willars, Christopher; Wendon, Julia A.; Auzinger, Georg [King' s College Hospital NHS Foundation Trust, The Institute of Liver Studies, King' s Health Partners, King' s College London, London (United Kingdom); Bosanac, Diana; Stefanidis, Konstantinos; Desai, Sujal R. [King' s College Hospital NHS Foundation Trust, Department of Radiology, King' s Health Partners, King' s College London, London (United Kingdom)

    2014-10-15

    To establish the relationship between CT signs of pulmonary hypertension and mean pulmonary artery pressure (mPAP) in patients with liver disease, and to determine the additive value of CT in the detection of portopulmonary hypertension in combination with transthoracic echocardiography. Forty-nine patients referred for liver transplantation were retrospectively reviewed. Measured CT signs included the main pulmonary artery/ascending aorta diameter ratio (PA/AA{sub meas}) and the mean left and right main PA diameter (RLPA{sub meas}). Enlargement of the pulmonary artery compared to the ascending aorta was also assessed visually (PA/AA{sub vis}). CT measurements were correlated with right-sided heart catheter-derived mPAP. The ability of PA/AA{sub vis} combined with echocardiogram-derived right ventricular systolic pressure (RVSP) to detect portopulmonary hypertension was tested with ROC analysis. There were moderate correlations between mPAP and both PA/AA{sub meas} and RLPA{sub meas} (r{sub s} = 0.41 and r{sub s} = 0.42, respectively; p < 0.005). Compared to transthoracic echocardiography alone (AUC = 0.59, p = 0.23), a diagnostic algorithm incorporating PA/AA{sub vis} and transthoracic echocardiography-derived RVSP improved the detection of portopulmonary hypertension (AUC = 0.8, p < 0.0001). CT contributes to the non-invasive detection of portopulmonary hypertension when used in a diagnostic algorithm with transthoracic echocardiography. CT may have a role in the pre-liver transplantation triage of patients with portopulmonary hypertension for right-sided heart catheterisation. (orig.)

  12. Guidelines for the Use of Echocardiography in the Evaluation of a Cardiac Source of Embolism.

    Science.gov (United States)

    Saric, Muhamed; Armour, Alicia C; Arnaout, M Samir; Chaudhry, Farooq A; Grimm, Richard A; Kronzon, Itzhak; Landeck, Bruce F; Maganti, Kameswari; Michelena, Hector I; Tolstrup, Kirsten

    2016-01-01

    Embolism from the heart or the thoracic aorta often leads to clinically significant morbidity and mortality due to transient ischemic attack, stroke or occlusion of peripheral arteries. Transthoracic and transesophageal echocardiography are the key diagnostic modalities for evaluation, diagnosis, and management of stroke, systemic and pulmonary embolism. This document provides comprehensive American Society of Echocardiography guidelines on the use of echocardiography for evaluation of cardiac sources of embolism. It describes general mechanisms of stroke and systemic embolism; the specific role of cardiac and aortic sources in stroke, and systemic and pulmonary embolism; the role of echocardiography in evaluation, diagnosis, and management of cardiac and aortic sources of emboli including the incremental value of contrast and 3D echocardiography; and a brief description of alternative imaging techniques and their role in the evaluation of cardiac sources of emboli. Specific guidelines are provided for each category of embolic sources including the left atrium and left atrial appendage, left ventricle, heart valves, cardiac tumors, and thoracic aorta. In addition, there are recommendation regarding pulmonary embolism, and embolism related to cardiovascular surgery and percutaneous procedures. The guidelines also include a dedicated section on cardiac sources of embolism in pediatric populations. Copyright © 2016 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  13. The medical Doppler in hand surgery: its scientific basis, applications, and the history of its namesake, Christian Johann Doppler.

    Science.gov (United States)

    Ghori, Ahmer K; Chung, Kevin C

    2007-12-01

    The word Doppler is used synonymously in hand surgery for evaluating patency of vascular structures; however, the science and history behind the Doppler effect are not as well-known. We will present the theories behind the Doppler effect and the history of the person who made this discovery.

  14. Value of dobutamine stress tissue Doppler in evaluation of LV ...

    African Journals Online (AJOL)

    Shaimaa Ahmed Mostafa

    2014-12-12

    Dec 12, 2014 ... Prediction of functional recovery, based on the detection of contractile reserve with dobutamine stress echocardiography. (DSE), includes myocardial perfusion imaging, metabolic imaging with conventional scintigraphy and positron emission tomography (PET).12. Dobutamine stress echocardiography is ...

  15. Myocardial left ventricular dysfunction in patients with systemic lupus erythematosus: new insights from tissue Doppler and strain imaging.

    Science.gov (United States)

    Buss, Sebastian J; Wolf, David; Korosoglou, Grigorios; Max, Regina; Weiss, Celine S; Fischer, Christian; Schellberg, Dieter; Zugck, Christian; Kuecherer, Helmut F; Lorenz, Hanns-Martin; Katus, Hugo A; Hardt, Stefan E; Hansen, Alexander

    2010-01-01

    Systemic lupus erythematosus (SLE) is associated with high cardiovascular morbidity and mortality. Cardiovascular involvement is frequently underestimated by routine imaging techniques. Our aim was to determine if new echocardiographic imaging modalities like tissue Doppler (TDI), strain rate (SRR), and strain (SRI) imaging detect abnormalities in left ventricular (LV) function in asymptomatic patients with SLE. Sixty-seven young patients with SLE (mean age 42 +/- 10 yrs) without typical symptoms or signs of heart failure or angina, and a matched healthy control group (n = 40), underwent standard transthoracic echocardiography, TDI, SRR, and SRI imaging of the LV as well as assessment of disease characteristics. Despite findings within the normal range on routine standard 2-dimensional echocardiography, SLE was associated with significantly impaired systolic and diastolic myocardial velocities of the LV measured by TDI [mean global TDI: systolic (s): 2.9 +/- 0.9 vs 3.9 +/- 0.7 cm/s, p < 0.05; early (e): 4.3 +/- 1.5 vs 6.3 +/- 1.3 cm/s, p < 0.05; late (a): 2.9 +/- 0.8 vs 3.4 +/- 0.8 cm/s, p < 0.05; values +/- SD); SRR (s: -0.8 +/- 0.1 vs -1.1 +/- 0.1 s(-1); e: 1.1 +/- 0.2 vs 1.6 +/- 0.3 s(-1); a: 0.7 +/- 0.1 vs 1.0 +/- 0.2 s(-1); all p < 0.05); and SR (-15.11 +/- 2.2% vs -19.7 +/- 1.9%; p < 0.05) compared to the control group. Further, elevated disease activity, measured with the ECLAM and the SLEDAI score, resulted in significantly lower values for LV longitudinal function measured by SRR and SR, but not by TDI. SLE is associated with a significant impairment of systolic and diastolic LV longitudinal function in patients without cardiac symptoms. New imaging modalities provide earlier insight into cardiovascular involvement in SLE and seem to be superior to standard echocardiography to detect subclinical myocardial disease.

  16. P Wave Dispersion is Increased in Pulmonary Stenosis

    Directory of Open Access Journals (Sweden)

    Namik Ozmen

    2006-01-01

    Full Text Available Aim: The right atrium pressure load is increased in pulmonary stenosis (PS that is a congenital anomaly and this changes the electrophysiological characteristics of the atria. However, there is not enough data on the issue of P wave dispersion (PWD in PS. Methods: Forty- two patients diagnosed as having valvular PS with echocardiography and 33 completely healthy individuals as the control group were included in the study. P wave duration, p wave maximum (p max and p minimum (p min were calculated from resting electrocariography (ECG obtained at the rate of 50 mm/sec. P wave dispersion was derived by subtracting p min from p max. The mean pressure gradient (MPG at the pulmonary valve, structure of the valve and diameters of the right and left atria were measured with echocardiography. The data from two groups were compared with the Mann-Whitney U test and correlation analysis was performed with the Pearson correlation technique. Results: There wasn’t any statistically significance in the comparison of age, left atrial diameter and p min between two groups. While the MPG at the pulmonary valve was 43.11 ± 18.8 mmHg in PS patients, it was 8.4 ± 4.5 mmHg in the control group. While p max was 107.1 ± 11.5 in PS group, it was 98.2 ± 5.1 in control group (p=0.01, PWD was 40.4 ± 1.2 in PS group, and 27.2 ± 9.3 in the control group (p=0.01Moreover, while the diameter of the right atrium in PS group was greater than that of the control group, (38.7 ± 3.9 vs 30.2 ± 2.5, p=0.02. We detected a correlation between PWD and pressure gradient in regression analysis. Conclusion: P wave dispersion and p max are increased in PS. While PWD was correlated with the pressure gradient that is the degree of narrowing, it was not correlated with the diameters of the right and left atria.

  17. Noncoherent Doppler tracking: first flight results

    Science.gov (United States)

    DeBoy, Christopher C.; Robert Jensen, J.; Asher, Mark S.

    2005-01-01

    Noncoherent Doppler tracking has been devised as a means to achieve highly accurate, two-way Doppler measurements with a simple, transceiver-based communications system. This technique has been flown as an experiment on the Thermosphere, Ionosphere, Mesosphere, Energetics and Dynamics (TIMED) spacecraft, (launched 7 December 2001), as the operational technique for Doppler tracking on CONTOUR, and is baselined on several future deep space missions at JHU/APL. This paper reports on initial results from a series of successful tests of this technique between the TIMED spacecraft and NASA ground stations in the Deep Space Network. It also examines the advantages that noncoherent Doppler tracking and a transceiver-based system may offer to small satellite systems, including reduced cost, mass, and power.

  18. Acute right ventricular dysfunction: real-time management with echocardiography.

    Science.gov (United States)

    Krishnan, Sundar; Schmidt, Gregory A

    2015-03-01

    In critically ill patients, the right ventricle is susceptible to dysfunction due to increased afterload, decreased contractility, or alterations in preload. With the increased use of point-of-care ultrasonography and a decline in the use of pulmonary artery catheters, echocardiography can be the ideal tool for evaluation and to guide hemodynamic and respiratory therapy. We review the epidemiology of right ventricular failure in critically ill patients; echocardiographic parameters for evaluating the right ventricle; and the impact of mechanical ventilation, fluid therapy, and vasoactive infusions on the right ventricle. Finally, we summarize the principles of management in the context of right ventricular dysfunction and provide recommendations for echocardiography-guided management.

  19. Anomalous Doppler effects in bulk phononic crystal

    International Nuclear Information System (INIS)

    Cai Feiyan; He Zhaojian; Zhang Anqi; Ding Yiqun; Liu Zhengyou

    2010-01-01

    Doppler effects in simple cubic phononic crystal are studied theoretically and numerically. In addition to observing Doppler shifts from a moving source's frequencies inside the gap, we find that Doppler shifts can be multi-order, anisotropic, and the dominant order of shift depends on the band index that the source's frequency is in.

  20. Hydronephrosis and pregnancy: study with Doppler echography. Hidronefrosis y embarazo: estudio mediante ecografia Doppler

    Energy Technology Data Exchange (ETDEWEB)

    Ripolles Gonzalez, T.R.; Ambit Capdevilla, S.; Sanguesa Nebot, C.; Lazaro, S. de; Garcia Vila, J.H.; Belloch Ugarte, V.

    1993-01-01

    An 18-month study was performed to establish the normal intrarenal resistance index during pregnancy, in order to determine whether it differed significantly depending on the week of gestation or the degree of hydronephrosis. For this purpose , the flow velocity waves obtained in right kidney were analyzed in a group of 112 patients on the basis of 209 explorations. The kidneys were classified as grade 0,I,II, or III according to the degree of hydronephrosis. Doppler signal sampling was carried out at the level of the corticomedullary junction. From the results of the study it can be deduced that the index of intrarenal resistance during pregnancy is similar to that of the general population, that there are no significant differences among the groups with different degree of hydronephrosis and that the index does not vary according to the different weeks of gestation. These findings suggest that, during pregnancy, a pathological resistance index in a kidney should not be attributed to the physiological changes associated with normal gestation. (Author) 21 refs.

  1. The Coincident Coherence of Extreme Doppler Velocity Events with p-mode Patches in the Solar Photosphere.

    Science.gov (United States)

    McClure, Rachel Lee

    2018-06-01

    Observations of the solar photosphere show many spatially compact Doppler velocity events with short life spans and extreme values. In the IMaX spectropolarimetric inversion data of the first flight of the SUNRISE balloon in 2009 these striking flashes in the intergranule lanes and complementary outstanding values in the centers of granules have line of sight Doppler velocity values in excess of 4 sigma from the mean. We conclude that values outside 4 sigma are a result from the superposition of the granulation flows and the p-modes.To determine how granulation and p-modes contribute to these outstanding Doppler events, I separate the two components using the Fast Fourier Transform. I produce the power spectrum of the spatial wave frequencies and their corresponding frequency in time for each image, and create a k-omega filter to separate the two components. Using the filtered data, test the hypothesis that extreme events occur because of strict superposition between the p-mode Doppler velocities and the granular velocities. I compare event counts from the observational data to those produced by random superposition of the two flow components and find that the observational event counts are consistent with the model event counts in the limit of small number statistics. Poisson count probabilities of event numbers observed are consistent with expected model count probability distributions.

  2. Student tutors for hands-on training in focused emergency echocardiography – a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Kühl Matthias

    2012-10-01

    Full Text Available Abstract Background Focused emergency echocardiography performed by non-cardiologists has been shown to be feasible and effective in emergency situations. During resuscitation a short focused emergency echocardiography has been shown to narrow down potential differential diagnoses and to improve patient survival. Quite a large proportion of physicians are eligible to learn focused emergency echocardiography. Training in focused emergency echocardiography usually comprises a lecture, hands-on trainings in very small groups, and a practice phase. There is a shortage of experienced echocardiographers who can supervise the second step, the hands-on training. We thus investigated whether student tutors can perform the hands-on training for focused emergency echocardiography. Methods A total of 30 volunteer 4th and 5th year students were randomly assigned to a twelve-hour basic echocardiography course comprising a lecture followed by a hands-on training in small groups taught either by an expert cardiographer (EC or by a student tutor (ST. Using a pre-post-design, the students were evaluated by an OSCE. The students had to generate two still frames with the apical five-chamber view and the parasternal long axis in five minutes and to correctly mark twelve anatomical cardiac structures. Two blinded expert cardiographers rated the students’ performance using a standardized checklist. Students could achieve a maximum of 25 points. Results Both groups showed significant improvement after the training (p Conclusions Hands-on training by student tutors led to a significant gain in echocardiography skills, although inferior to teaching by an expert cardiographer.

  3. A combined wave distribution function and stability analysis of Viking particle and low-frequency wave data

    International Nuclear Information System (INIS)

    Oscarsson, T.E.; Roennmark, K.G.

    1990-01-01

    In this paper the authors present an investigation of low-frequency waves observed on auroral field lines below the acceleration region by the Swedish satellite Viking. The measured frequency spectra are peaked at half the local proton gyrofrequency, and the waves are observed in close connection with precipitating electrons. In order to obtain information about the distribution of wave energy in wave vector space, they reconstruct the wave distribution function (WDF) from observed spectral densities. They use a new scheme that allows them to reconstruct simultaneously the WDF over a broad frequency band. The method also makes it possible to take into account available particle observations as well as Doppler shifts caused by the relative motion between the plasma and the satellite. The distribution of energy in wave vector space suggested by the reconstructed WDF is found to be consistent with what is expected from a plasma instability driven by the observed precipitating electrons. Furthermore, by using UV images obtained on Viking, they demonstrate that the wave propagation directions indicated by the reconstructed WDFs are consistent with a simple model of the presumed wave source in the electron precipitation region

  4. Left Ventricular Myocardial Deformation Parameters Are Affected by Coronary Slow Flow Phenomenon: A Study of Speckle Tracking Echocardiography.

    Science.gov (United States)

    Gulel, Okan; Akcay, Murat; Soylu, Korhan; Aksan, Gokhan; Yuksel, Serkan; Zengin, Halit; Meric, Murat; Sahin, Mahmut

    2016-05-01

    The coronary slow flow phenomenon (CSFP) is defined as a delayed distal vessel contrast opacification in the absence of obstructive epicardial coronary artery disease during coronary angiography. There is conflicting data in medical literature regarding the effects of CSFP on the left ventricular functions assessed by conventional echocardiography or tissue Doppler imaging. Therefore, we aimed to evaluate whether there is any abnormality in the myocardial deformation parameters (strain, strain rate (SR), rotation, twist) of the left ventricle obtained by speckle tracking echocardiography (STE) in patients with CSFP. Twenty patients with CSFP were included prospectively in the study. Another 20 patients with similar demographics and cardiovascular risk factors as well as normal coronary angiography were used as the control group. Two-dimensional echocardiographic images of the left ventricle from the apical long-axis, two-chamber, four-chamber, and parasternal short-axis views were used for STE analysis. The analysis of left ventricular circumferential deformation parameters showed that the averaged peak systolic strain, systolic SR, and early diastolic SR values were significantly lower in patients with CSFP (P = 0.009, P = 0.02, and P = 0.02, respectively). Among the left ventricular rotation and twist values, apical rotation was significantly lower in patients with CSFP (P = 0.02). Further, the mean thrombolysis in myocardial infarction frame count value was found to be negatively correlated with the averaged peak circumferential early diastolic SR (r = -0.35, P = 0.03). It was positively correlated with the averaged peak circumferential systolic strain (r = 0.47, P = 0.003) and circumferential systolic SR (r = 0.46, P = 0.005). Coronary slow flow phenomenon leads to significant alterations in the myocardial deformation parameters of the left ventricle as assessed by STE. Specifically, circumferential deformation parameters are affected in CSFP patients. © 2015

  5. Prognostic Value of Transthoracic Doppler Echocardiography Coronary Flow Velocity Reserve in Patients with Nonculprit Stenosis of Intermediate Severity Early after Primary Percutaneous Coronary Intervention.

    Science.gov (United States)

    Tesic, Milorad; Djordjevic-Dikic, Ana; Giga, Vojislav; Stepanovic, Jelena; Dobric, Milan; Jovanovic, Ivana; Petrovic, Marija; Mehmedbegovic, Zlatko; Milasinovic, Dejan; Dedovic, Vladimir; Zivkovic, Milorad; Juricic, Stefan; Orlic, Dejan; Stojkovic, Sinisa; Vukcevic, Vladan; Stankovic, Goran; Nedeljkovic, Milan; Ostojic, Miodrag; Beleslin, Branko

    2018-04-03

    Treatment of nonculprit coronary stenosis during primary percutaneous coronary intervention in patients with ST-segment elevation myocardial infarction may be beneficial, but the mode and timing of the intervention are still controversial. The aim of this study was to examine the significance and prognostic value of preserved coronary flow velocity reserve (CFVR) in patients with nonculprit intermediate stenosis early after primary percutaneous coronary intervention. Two hundred thirty patients with remaining intermediate (50%-70%) stenosis of non-infarct-related arteries, in whom CFVR was performed within 7 days after primary percutaneous coronary intervention, were prospectively enrolled. Twenty patients with reduced CFVR and positive results on stress echocardiography or impaired fractional flow reserve underwent revascularization and were not included in further analysis. The final study population of 210 patients (mean age, 58 ± 10 years; 162 men) was divided into two groups on the basis of CFVR: group 1, CFVR > 2 (n = 174), and group 2, CFVR ≤ 2 (n = 36). Cardiac death, nonfatal myocardial infarction, and revascularization of the evaluated vessel were considered adverse events. Mean follow-up duration was 47 ± 16 months. Mean CFVR for the whole group was 2.36 ± 0.40. There were six adverse events (3.4%) related to the nonculprit coronary artery in group 1, including one cardiac death, one ST-segment elevation myocardial infarction, and four revascularizations. In group 2, there were 30 adverse events (83.3%, P  2 of the intermediate nonculprit coronary lesion, deferral of revascularization is safe and associated with excellent long-term clinical outcomes. Copyright © 2018 American Society of Echocardiography. Published by Elsevier Inc. All rights reserved.

  6. Measurement of fast-changing low velocities by photonic Doppler velocimetry

    Energy Technology Data Exchange (ETDEWEB)

    Song Hongwei; Wu Xianqian; Huang Chenguang; Wei Yangpeng; Wang Xi [Key Laboratory for Hydrodynamics and Ocean Engineering, Institute of Mechanics, Chinese Academy of Sciences, Beijing 100190 (China)

    2012-07-15

    Despite the increasing popularity of photonic Doppler velocimetry (PDV) in shock wave experiments, its capability of capturing low particle velocities while changing rapidly is still questionable. The paper discusses the performance of short time Fourier transform (STFT) and continuous wavelet transform (CWT) in processing fringe signals of fast-changing low velocities measured by PDV. Two typical experiments are carried out to evaluate the performance. In the laser shock peening test, the CWT gives a better interpretation to the free surface velocity history, where the elastic precursor, main plastic wave, and elastic release wave can be clearly identified. The velocities of stress waves, Hugoniot elastic limit, and the amplitude of shock pressure induced by laser can be obtained from the measurement. In the Kolsky-bar based tests, both methods show validity of processing the longitudinal velocity signal of incident bar, whereas CWT improperly interprets the radial velocity of the shocked sample at the beginning period, indicating the sensitiveness of the CWT to the background noise. STFT is relatively robust in extracting waveforms of low signal-to-noise ratio. Data processing method greatly affects the temporal resolution and velocity resolution of a given fringe signal, usually CWT demonstrates a better local temporal resolution and velocity resolution, due to its adaptability to the local frequency, also due to the finer time-frequency product according to the uncertainty principle.

  7. Effect of Mitral Annular Calcium on Left Ventricular Diastolic Parameters.

    Science.gov (United States)

    Codolosa, Jose N; Koshkelashvili, Nikoloz; Alnabelsi, Talal; Goykhman, Igor; Romero-Corral, Abel; Pressman, Gregg S

    2016-03-01

    Assessment of left ventricular (LV) diastolic function by Doppler flow imaging and tissue Doppler is an integral part of the echocardiographic examination. Mitral annular calcium (MAC) is frequently encountered on echocardiography. The aim of this study was to assess the impact of MAC, quantitatively measured by computed tomography scan, on echocardiographic LV diastolic parameters. We included 155 patients aged ≥65 years. Computed tomography reconstructions of the mitral annulus were created, and calcium identified and quantified by Agatston technique. Calcium locations were assigned using an overlaid template depicting the annular segments in relation to surrounding anatomic structures. Echocardiographic assessment of diastolic function was performed in standard fashion. Mean age was 77 years; 49% were men; and 43% were black. Patients with MAC had lower septal e' (p = 0.003), lateral e' (p = 0.04), and average e' (p = 0.01) compared with those without MAC. They also had a higher E-wave velocity (p = 0.01) and E/e' ratio (p <0.001). When evaluated by severity of MAC, and after adjustment for multiple clinical factors, there was a graded (inverse) relation between MAC severity and septal e' (p = 0.01), lateral e' (p = 0.01), and average e' (p = 0.01). In conclusion, LV diastolic parameters, as measured by Doppler echocardiography, are altered in the presence of MAC. This could be due to direct effects of MAC on annular function or might reflect truly reduced diastolic function. Interpretation of diastolic parameters in patients with MAC should be performed with caution. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Addition of rituximab to chop does not increase the risk of cardiotoxicity in patients with non-Hodgkin's lymphoma.

    Science.gov (United States)

    Kilickap, Saadettin; Yavuz, Bunyamin; Aksoy, Sercan; Sahiner, Levent; Dincer, Murat; Harputluoglu, Hakan; Erman, Mustafa; Aytemir, Kudret; Tokgozoglu, Lale; Barista, Ibrahim

    2008-01-01

    The addition of rituximab to doxorubicin-containing standard chemotherapy significantly improves response to therapy and reduces the risk of death in B-cell non-Hodgkin's lymphoma (NHL) patients. However, the impact of this approach on doxorubicin-induced cardiotoxicity has not been elucidated. Patients who had been planned to receive CHOP or rituximab plus CHOP (R-CHOP) combination chemotherapy with a diagnosis of NHL were included in the study. In all patients, systolic and diastolic parameters were measured by using conventional and pulsed-wave tissue Doppler echocardiography, which is more sensitive than conventional lead-dependent techniques, both before and in the sixth month of therapy. There were 28 (M/F; 14/14) patients on CHOP and 33 (M/F; 16/17) patients on R-CHOP. Median age in CHOP and R-CHOP was 49 and 50 years (P = 0.44), respectively. Cumulative doxorubicin doses were 280 and 286 mg/m(2) on CHOP and R-CHOP (P = 0.65), respectively. None of the patients developed clinically evident congestive heart failure. Parameters of systolic function such as LVEF and FS did not significantly change in any patients. In both arms, tissue Doppler parameters of diastolic function such as lateral E and septal E velocity of mitral annulus decreased significantly after therapy (P 0.05). Conventional Doppler echocardiography yielded consistent findings. Both CHOP and R-CHOP cause diastolic dysfunction in the early period following their administration. The addition of rituximab to CHOP chemotherapy does not significantly increase the risk of doxorubicin-induced cardiotoxicity during this period.

  9. Transesophageal echocardiography in the assessment of coronary arteries

    International Nuclear Information System (INIS)

    Adamek-Kosmider, A.; Kasprzak, J.; Kosmider, M.; Krzeminska-Pakula, M.

    1993-01-01

    The study was undertaken to assess the usefulness of TEE for evaluation of morphology and flow in coronary arteries. TEE (2D, spectral and color Doppler imaging) and coronary angiography were performed in 75 patients - 41 with valvular heart disease and 34 with ischemic heart disease. Proximal coronary artery stenosis was detected by coronarography in 11 pts (9-left main coronary artery, 2-right coronary artery). TEE visualization of proximal coronary arteries was possible in all pts. Echocardiographic features of artery stenosis were: the narrowing of the vessel in 2D image (9 pts), high flow velocity spectral Doppler (4 pts, mean 135 cm/s vs 55 cm/s in normal arteries) and mosaic, turbulent flow in color Doppler (10 pts). Sensitivity and specificity of TEE for coronary artery stenosis detection was respectively 81%/98% for 2D imaging and 90%/100% for color Doppler. TEE is a new, noninvasive and safe method for the evaluation of proximal coronary arteries. Detection of LMCA stenosis prior to atheterization may enhance the safety of coronary angiography. (author)

  10. P Wave Duration And Dispersion In Patients With Hyperthyroidism And The Short-term Effects Of Antithyroid Treatment

    OpenAIRE

    Unal Guntekin; Yilmaz Gunes; Hakki Simsek; Mustafa Tuncer; Sevket Arslan

    2009-01-01

    Background: Prolonged P wave duration and P wave dispersion (PWD) have been associated with an increased risk for atrial fibrillation (AF). Hyperthytodism is a frequent cause of atrial fibrillation (AF). Methods: Forty-two patients with newly diagnosed overt hyperthyroidism and 20 healthy people were enrolled in the study. Transthoracic echocardiography, 12 lead surface ECG and thyroid hormone levels were studied at the time of enrollment and after achievement of euthyroid state with propylth...

  11. An investigation into the causes of unexpected intra-operative transoesophageal echocardiography findings.

    Science.gov (United States)

    Skinner, H J; Mahmoud, A; Uddin, A; Mathew, T

    2012-04-01

    There is uncertainty regarding echocardiography before cardiac surgery, especially with regard to timing and disease progression as well as potential errors. We investigated the causes of unexpected intra-operative transoesophageal echocardiography findings by performing a 33-month audit. We found that there were 50/797 (6%) unexpected findings that led to an alteration in surgical strategy in 34 (4%) patients. Of the unexpected findings, 25 (50%) were unrelated to pre-operative pathology. After reviewing pre-operative studies and reports, unexpected findings were found to be due to: reporting errors in 20 patients (44%); limitations in transthoracic compared to transoesophageal echocardiography in 14 patients (30%); disease progression in 10 patients (22%); and inter-observer variability in two patients (4%). We identified six reports out of 797 (0.8%) that contained potentially serious errors. Surgical management changed in 18/20 (90%) patients in whom the unexpected change was due to reporting error, compared to 16/30 (53%) patients whose pre-operative echocardiogram was correctly reported (p = 0.006). Our study suggests that pre-operative echocardiography reporting errors are common and important. Anaesthesia © 2012 The Association of Anaesthetists of Great Britain and Ireland.

  12. The Role of Stress Echocardiography in Valvular Heart Disease: A Current Appraisal.

    Science.gov (United States)

    Gentry Iii, James L; Phelan, Dermot; Desai, Milind Y; Griffin, Brian P

    Stress echocardiography is a widely available, safe, low-cost, versatile imaging modality which is becoming increasingly recognized as a valuable tool in the assessment of patients with native and prosthetic left-sided valvular heart disease. It provides a quantitative assessment to help guide clinical decision-making when discordance exists between symptoms and severity of valve disease. Exercise (treadmill or bicycle) remains the preferred stress modality, but pharmacological augmentation with dobutamine can be used if needed. Low-dose dobutamine stress echocardiography is specifically valuable in patients with low-flow, low-gradient aortic stenosis when attempting to differentiate true severe aortic stenosis from pseudo-severe aortic stenosis. Stress echocardiography not only identifies high-risk features that indicate need for earlier surgery, it also provides useful information for the peri- and postoperative period, including long-term outcome, risk stratification to guide monitoring frequency, and offers guidance for eligibility in competitive sports participation. As research continues to expand the utility of stress echocardiography in the management of patients with valvular heart disease, future research should focus on the recognition of newer parameters identifying high-risk features including subsequent validation in a large population. © 2017 S. Karger AG, Basel.

  13. Minimally destructive Doppler measurement of a quantized, superfluid flow

    Science.gov (United States)

    Anderson, Neil; Kumar, Avinash; Eckel, Stephen; Stringari, Sandro; Campbell, Gretchen

    2016-05-01

    Ring shaped Bose-Einstein condensates are of interest because they support the existence of quantized, persistent currents. These currents arise because in a ring trap, the wavefunction of the condensate must be single valued, and thus the azimuthal velocity is quantized. Previously, these persistent current states have only been measured in a destructive fashion via either interference with a phase reference or using the size of a central vortex-like structure that appears in time of flight. Here, we demonstrate a minimally destructive, in-situ measurement of the winding number of a ring shaped BEC. We excite a standing wave of phonon modes in the ring BEC using a perturbation. If the condensate is in a nonzero circulation state, then the frequency of these phonon modes are Doppler shifted, causing the standing wave to precess about the ring. From the direction and velocity of this precession, we can infer the winding number of the flow. For certain parameters, this technique can detect individual winding numbers with approximately 90% fidelity.

  14. Results of a Prospective Echocardiography Trial in International Space Station Crew

    Science.gov (United States)

    Hamilton, Douglas R.; Sargsyan, Ashot E.; Martin, David; Garcia, Kathleen M.; Melton, Shannon; Feiverson, Alan; Dulchavsky, Scott A.

    2009-01-01

    In the framework of an operationally oriented investigation, we conducted a prospective trial of a standard clinical echocardiography protocol in a cohort of long-duration crewmembers. The resulting primary and processed data appear to have no precedents. Our tele-echocardiography paradigm, including just-in-time e-training methods, was also assessed. A critical review of the imaging technique, equipment and setting limitations, and quality assurance is provided, as well as the analysis of "space normal" data.

  15. Wave Breaking, Bubble Production and Acoustic Characteristics of the Surf Zone, SIO Component

    National Research Council Canada - National Science Library

    Deane, Grant

    2001-01-01

    .... The purpose of these measurements was to: (1) statistically characterize the surf zone acoustic channel Doppler and time spreads, and acoustic drop-outs, in terms of the incident wave field and (2...

  16. Phase Doppler anemometry as an ejecta diagnostic

    Science.gov (United States)

    Bell, D. J.; Chapman, D. J.

    2017-01-01

    When a shock wave is incident on a free surface, micron sized pieces of the material can be ejected from that surface. Phase Doppler Anemometry (PDA) is being developed to simultaneously measure the sizes and velocities of the individual shock induced ejecta particles; providing an important insight into ejecta phenomena. The results from experiments performed on the 13 mm bore light gas gun at the Institute of Shock Physics, Imperial College London are presented. Specially grooved tin targets were shocked at pressures of up to 14 GPa, below the melt on release pressure, to generate ejecta particles. These experiments are the first time that PDA has been successfully fielded on dynamic ejecta experiments. The results and current state of the art of the technique are discussed along with the future improvements required to optimise performance and increase usability.

  17. Damage detection in composite panels based on mode-converted Lamb waves sensed using 3D laser scanning vibrometer

    Science.gov (United States)

    Pieczonka, Łukasz; Ambroziński, Łukasz; Staszewski, Wiesław J.; Barnoncel, David; Pérès, Patrick

    2017-12-01

    This paper introduces damage identification approach based on guided ultrasonic waves and 3D laser Doppler vibrometry. The method is based on the fact that the symmetric and antisymmetric Lamb wave modes differ in amplitude of the in-plane and out-of-plane vibrations. Moreover, the modes differ also in group velocities and normally they are well separated in time. For a given time window both modes can occur simultaneously only close to the wave source or to a defect that leads to mode conversion. By making the comparison between the in-plane and out-of-plane wave vector components the detection of mode conversion is possible, allowing for superior and reliable damage detection. Experimental verification of the proposed damage identification procedure is performed on fuel tank elements of Reusable Launch Vehicles designed for space exploration. Lamb waves are excited using low-profile, surface-bonded piezoceramic transducers and 3D scanning laser Doppler vibrometer is used to characterize the Lamb wave propagation field. The paper presents theoretical background of the proposed damage identification technique as well as experimental arrangements and results.

  18. Estimating the Doppler centroid of SAR data

    DEFF Research Database (Denmark)

    Madsen, Søren Nørvang

    1989-01-01

    attractive properties. An evaluation based on an existing SEASAT processor is reported. The time-domain algorithms are shown to be extremely efficient with respect to requirements on calculations and memory, and hence they are well suited to real-time systems where the Doppler estimation is based on raw SAR......After reviewing frequency-domain techniques for estimating the Doppler centroid of synthetic-aperture radar (SAR) data, the author describes a time-domain method and highlights its advantages. In particular, a nonlinear time-domain algorithm called the sign-Doppler estimator (SDE) is shown to have...... data. For offline processors where the Doppler estimation is performed on processed data, which removes the problem of partial coverage of bright targets, the ΔE estimator and the CDE (correlation Doppler estimator) algorithm give similar performance. However, for nonhomogeneous scenes it is found...

  19. Association of heart failure hospitalizations with combined electrocardiography and echocardiography criteria for left ventricular hypertrophy

    DEFF Research Database (Denmark)

    Gerdts, Eva; Okin, Peter M; Boman, Kurt

    2012-01-01

    The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain.......The value of performing echocardiography in hypertensive patients with electrocardiographic left ventricular hypertrophy (LVH) is uncertain....

  20. Assessment of Myocardial Ischemia in Obese Individuals Undergoing Physical Stress Echocardiography (PSE

    Directory of Open Access Journals (Sweden)

    Mara Graziele Maciel Silveira

    2015-05-01

    Full Text Available Background: Physical stress echocardiography is an established methodology for diagnosis and risk stratification of coronary artery disease in patients with physical capacity. In obese (body mass index ≥ 30 kg/m2 the usefulness of pharmacological stress echocardiography has been demonstrated; however, has not been reported the use of physical stress echocardiography in this growing population group. Objective: To assess the frequency of myocardial ischemia in obese and non-obese patients undergoing physical stress echocardiography and compare their clinical and echocardiographic differences. Methods: 4,050 patients who underwent treadmill physical stress echocardiography were studied according to the Bruce protocol, divided into two groups: obese (n = 945; 23.3% and non-obese (n = 3,105; 76.6%. Results: There was no difference regarding gender. Obese patients were younger (55.4 ± 10.9 vs. 57.56 ± 11.67 and had a higher frequency of hypertension (75.2% vs. 57, 2%; p < 0.0001, diabetis mellitus (15.2% vs. 10.9%; p < 0.0001, dyslipidemia (59.5% vs 51.9%; p < 0.0001, family history of coronary artery disease (59.3% vs. 55.1%; p = 0.023 and physical inactivity (71.4% vs. 52.9%, p < 0.0001. The obese had greater aortic dimensions (3.27 vs. 3.14 cm; p < 0.0001, left atrium (3.97 vs. 3.72 cm; p < 0.0001 and the relative thickness of the ventricule (33.7 vs. 32.8 cm; p < 0.0001. Regarding the presence of myocardial ischemia, there was no difference between groups (19% vs. 17.9%; p = 0.41. In adjusted logistic regression, the presence of myocardial ischemia remained independently associated with age, female gender, diabetes and hypertension. Conclusion: Obesity did not behave as a predictor of the presence of ischemia and the physical stress echocardiography. The application of this assessment tool in large scale sample demonstrates the feasibility of the methodology, also in obese.