WorldWideScience

Sample records for wave discharges evoked

  1. Conditioning effect of transcranial magnetic stimulation evoking motor-evoked potential on V-wave response.

    Science.gov (United States)

    Grosprêtre, Sidney; Martin, Alain

    2014-12-01

    The aim of this study was to examine the collision responsible for the volitional V-wave evoked by supramaximal electrical stimulation of the motor nerve during voluntary contraction. V-wave was conditioned by transcranial magnetic stimulation (TMS) over the motor cortex at several inter-stimuli intervals (ISI) during weak voluntary plantar flexions (n = 10) and at rest for flexor carpi radialis muscle (FCR; n = 6). Conditioning stimulations were induced by TMS with intensity eliciting maximal motor-evoked potential (MEPmax). ISIs used were ranging from -20 to +20 msec depending on muscles tested. The results showed that, for triceps surae muscles, conditioning TMS increased the V-wave amplitude (~ +250%) and the associated mechanical response (~ +30%) during weak voluntary plantar flexion (10% of the maximal voluntary contraction -MVC) for ISIs ranging from +6 to +18 msec. Similar effect was observed at rest for the FCR with ISI ranging from +6 to +12 msec. When the level of force was increased from 10 to 50% MVC or the conditioning TMS intensity was reduced to elicit responses of 50% of MEPmax, a significant decrease in the conditioned V-wave amplitude was observed for the triceps surae muscles, linearly correlated to the changes in MEP amplitude. The slope of this correlation, as well as the electro-mechanical efficiency, was closed to the identity line, indicating that V-wave impact at muscle level seems to be similar to the impact of cortical stimulation. All these results suggest that change in V-wave amplitude is a great index to reflect changes in cortical neural drive addressed to spinal motoneurons.

  2. Electrical stimulation of the preoptic area in Eigenmannia: evoked interruptions in the electric organ discharge.

    Science.gov (United States)

    Wong, C J

    2000-01-01

    The functional role of the basal forebrain and preoptic regions in modulating the normally regular electric organ discharge was determined by focal brain stimulation in the weakly electric fish, Eigenmannia. The rostral preoptic area, which is connected with the diencephalic prepacemaker nucleus, was examined physiologically by electrical stimulation in a curarized fish. Electrical stimulation of the most rostral region of the preoptic area with trains of relatively low intensity current elicits discrete bursts of electric organ discharge interruptions in contrast to other forebrain loci. These responses were observed primarily as after-responses following the termination of the stimulus train and were relatively immune to variations in the stimulus parameters. As the duration and rate of these preoptic-evoked bursts of electric organ discharge interruptions (approximately 100 ms at 2 per s) are similar to duration and rate of natural interruptions, it is proposed that these bursts might be precursors to natural interruptions. These data suggest that the preoptic area, consistent with its role in controlling reproductive behaviors in vertebrates, may be influencing the occurrence of electric organ discharge courtship signals by either direct actions on the prepacemaker nucleus or through other regions that are connected with the diencephalic pre-pacemaker nucleus.

  3. Prestimulus amplitudes modulate P1 latencies and evoked traveling alpha waves

    Directory of Open Access Journals (Sweden)

    Nicole Alexandra Himmelstoss

    2015-05-01

    Full Text Available Traveling waves have been well documented in the ongoing, and more recently also in the evoked EEG. In the present study we investigate what kind of physiological process might be responsible for inducing an evoked traveling wave. We used a semantic judgment task which already proved useful to study evoked traveling alpha waves that coincide with the appearance of the P1 component. We found that the P1 latency of the leading electrode is significantly correlated with prestimulus amplitude size and that this event is associated with a transient change in alpha frequency. We assume that cortical background excitability, as reflected by an increase in prestimulus amplitude, is responsible for the observed change in alpha frequency and the initiation of an evoked traveling trajectory.

  4. CFD study of the overtopping discharge of the Wave Dragon wave energy converter

    DEFF Research Database (Denmark)

    Eskilsson, K.; Palm, J.; Kofoed, Jens Peter

    2015-01-01

    The Wave Dragon is a floating Wave Energy Converter (WEC) working by the overtopping principle. The overtopping discharge has been determined by model scale experiments in wave basins. In the present study we numerically simulate the overtopping behavior of the Wave Dragon device using a VOFbased...

  5. The stimulus-evoked population response in visual cortex of awake monkey is a propagating wave.

    Science.gov (United States)

    Muller, Lyle; Reynaud, Alexandre; Chavane, Frédéric; Destexhe, Alain

    2014-04-28

    Propagating waves occur in many excitable media and were recently found in neural systems from retina to neocortex. While propagating waves are clearly present under anaesthesia, whether they also appear during awake and conscious states remains unclear. One possibility is that these waves are systematically missed in trial-averaged data, due to variability. Here we present a method for detecting propagating waves in noisy multichannel recordings. Applying this method to single-trial voltage-sensitive dye imaging data, we show that the stimulus-evoked population response in primary visual cortex of the awake monkey propagates as a travelling wave, with consistent dynamics across trials. A network model suggests that this reliability is the hallmark of the horizontal fibre network of superficial cortical layers. Propagating waves with similar properties occur independently in secondary visual cortex, but maintain precise phase relations with the waves in primary visual cortex. These results show that, in response to a visual stimulus, propagating waves are systematically evoked in several visual areas, generating a consistent spatiotemporal frame for further neuronal interactions.

  6. Intensity improvement of shock waves induced by liquid electrical discharges

    Science.gov (United States)

    Liu, Yi; Li, Zhi-Yuan; Li, Xian-Dong; Liu, Si-Wei; Zhou, Gu-Yue; Lin, Fu-Chang

    2017-04-01

    When shock waves induced by pulsed electrical discharges in dielectric liquids are widely applied in industrial fields, it is necessary to improve the energy transfer efficiency from electrical energy to mechanical energy to improve the shock wave intensity. In order to investigate the effect of the plasma channel length created by the liquid electrical discharge on the shock wave intensity, a test stand of dielectric liquid pulsed electrical discharge is designed and constructed. The main capacitor is 3 μF, and the charging voltage is 0-30 kV. Based on the needle-needle electrode geometry with different gap distances, the intensities of shock waves corresponding to the electrical parameters, the relationship between the plasma channel length and the deposited energy, and the time-resolved observation of the plasma channel development by a high speed camera are presented and compared. The shock wave intensity is closely related to the power and energy dissipated into the plasma channel. The longer plasma channel and the quicker arc expansion can lead to a higher power and energy deposited into the plasma channel, which can activate a stronger shock wave.

  7. Sleep deprivation and spike-wave discharges in epileptic rats

    NARCIS (Netherlands)

    Drinkenburg, W.H.I.M.; Coenen, A.M.L.; Vossen, J.M.H.; Luijtelaar, E.L.J.M. van

    1995-01-01

    The effects of sleep deprivation were studied on the occurrence of spike-wave discharges in the electroencephalogram of rats of the epileptic WAG/Rij strain, a model for absence epilepsy. This was done before, during and after a period of 12 hours of near total sleep deprivation. A substantial incre

  8. Sleep deprivation and spike-wave discharges in epileptic rats

    NARCIS (Netherlands)

    Drinkenburg, W.H.I.M.; Coenen, A.M.L.; Vossen, J.M.H.; Luijtelaar, E.L.J.M. van

    1995-01-01

    The effects of sleep deprivation were studied on the occurrence of spike-wave discharges in the electroencephalogram of rats of the epileptic WAG/Rij strain, a model for absence epilepsy. This was done before, during and after a period of 12 hours of near total sleep deprivation. A substantial

  9. FAST TRACK COMMUNICATION: Small surface wave discharge at atmospheric pressure

    Science.gov (United States)

    Kiss'ovski, Zh; Kolev, M.; Ivanov, A.; Lishev, St.; Koleva, I.

    2009-09-01

    A small surface wave driven source produces plasma at atmospheric pressure. Microwave power at frequency 2.45 GHz is coupled with the source and a discharge is ignited at power levels below 10 W. The coaxial exciter of the surface waves has a length of 10 mm because its dielectric is a high permittivity discharge tube. The plasma source operates as a plasma jet in the case of plasma columns longer than the tube length. The source maintains stable plasma columns over a wide range of neutral gas flow and applied power in continuous and pulse regimes. An additional advantage of this source is the discharge self-ignition. An electron temperature of Te ~ 1.9 eV and a density of ne ~ 3.9 × 1014 cm-3 are estimated by the probe diagnostics method. The emission spectra in the wavelength range 200-1000 nm under different experimental conditions are analysed and they prove the applicability of the source for analytical spectroscopy. The dependences of column length, reflected power and plasma parameters on the gas flow and the input power are discussed.

  10. Generation of whistler-wave heated discharges with planar resonant RF networks.

    Science.gov (United States)

    Guittienne, Ph; Howling, A A; Hollenstein, Ch

    2013-09-20

    Magnetized plasma discharges generated by a planar resonant rf network are investigated. A regime transition is observed above a magnetic field threshold, associated with rf waves propagating in the plasma and which present the characteristics of whistler waves. These wave heated regimes can be considered as analogous to conventional helicon discharges, but in planar geometry.

  11. DEPRESSION OF THE PHOTIC AFTER DISCHARGE OF FLASH EVOKED POTENTIALS BY PHYSOSTIGMINE, CARBARYL AND PROPOXUR AND THE RELATIONSHIP TO INHIBITION OF BRAIN CHOLINESTERASE

    Science.gov (United States)

    The effects of N-methyl carbamate pesticides on the photic after discharge (PhAD) of flash evoked potentials (FEPs) and the relationship between inhibition of brain cholinesterase (ChE) activity and the PhAD were evaluated. FEPs were recorded in Long Evans rats treated with physo...

  12. DEPRESSION OF THE PHOTIC AFTER DISCHARGE OF FLASH EVOKED POTENTIALS BY PHYSOSTIGMINE, CARBARYL AND PROPOXUR AND THE RELATIONSHIP TO INHIBITION OF BRAIN CHOLINESTERASE

    Science.gov (United States)

    The effects of N-methyl carbamate pesticides on the photic after discharge (PhAD) of flash evoked potentials (FEPs) and the relationship between inhibition of brain cholinesterase (ChE) activity and the PhAD were evaluated. FEPs were recorded in Long Evans rats treated with physo...

  13. Deltas, freshwater discharge, and waves along the Young Sound, NE Greenland

    DEFF Research Database (Denmark)

    Kroon, Aart; Abermann, Jakob; Bendixen, Mette

    2017-01-01

    , and bathymetry), fluvial discharges and associated sediment load, and processes by waves and currents. Main factors steering the Arctic fluvial discharges into the Young Sound are the snow and ice melt and precipitation in the catchment, and extreme events like glacier lake outburst floods (GLOFs). Waves...

  14. Evolution of bed form height and length during a discharge wave

    NARCIS (Netherlands)

    Warmink, J.J.; Schielen, R.M.J.; Dohmen-Janssen, C.M.; Lancker, van V.; Garlan, T.

    2013-01-01

    This research focusses on modeling the evolution of bed form during a discharge wave for application in operational flood forecasting. The objective of this research was to analyze and predict the bed form evolution during a discharge wave in a flume experiment. We analyzed the data of a flume exper

  15. Effect Of Electromagnetic Waves Emitted From Mobile Phone On Brain Stem Auditory Evoked Potential In Adult Males.

    Science.gov (United States)

    Singh, K

    2015-01-01

    Mobile phone (MP) is commonly used communication tool. Electromagnetic waves (EMWs) emitted from MP may have potential health hazards. So, it was planned to study the effect of electromagnetic waves (EMWs) emitted from the mobile phone on brainstem auditory evoked potential (BAEP) in male subjects in the age group of 20-40 years. BAEPs were recorded using standard method of 10-20 system of electrode placement and sound click stimuli of specified intensity, duration and frequency.Right ear was exposed to EMW emitted from MP for about 10 min. On comparison of before and after exposure to MP in right ear (found to be dominating ear), there was significant increase in latency of II, III (p wave, amplitude of I-Ia wave (p wave (P waves of BAEP in left ear before vs after MP. On comparison of right (having exposure routinely as found to be dominating ear) and left ears (not exposed to MP), before exposure to MP, IPL of IIl-V wave and amplitude of V-Va is more (wave (< 0.001) in left ear. After exposure to MP, the amplitude of V-Va was (p < 0.05) more in right ear compared to left ear. In conclusion, EMWs emitted from MP affects the auditory potential.

  16. Second-harmonic plasma response in diffusion-controlled surface-wave-sustained discharges

    Science.gov (United States)

    Stoev, L.

    2008-05-01

    The formation of nonlinear plasma response at the second harmonic frequency in diffusion controlled surface-wave-sustained discharges is studied theoretically. The study is aimed at estimating theoretically the ratio of the squared amplitudes of the wave field of fundamental frequency and of the resulting - from the nonlinear effects - electric field at the second harmonic frequency. The model presented is intended for further use in discharge diagnostics.

  17. Stability of Global Alfven Waves (Tae, Eae) in Jet Tritium Discharges

    NARCIS (Netherlands)

    Kerner, W.; Borba, D.; Huysmans, G. T. A.; Porcelli, F.; Poedts, S.; Goedbloed, J. P.; Betti, R.

    1994-01-01

    The interaction of alpha-particles in JET tritium discharges with global Alfven waves via inverse Landau damping is analysed. It is found that alpha-particle driven eigenmodes were stable in the PTE1 and should also be stable in a future 50:50 deuterium-tritium mix discharge aiming at Q(DT) = 1,

  18. Material basis for inhibition of Dragon's Blood on evoked discharges of wide dynamic range neurons in spinal dorsal horn of rats

    Institute of Scientific and Technical Information of China (English)

    GUO Min; CHEN Su; LIU XiangMing

    2008-01-01

    In vivo experiments were designed to verify the analgesic effect of Dragon's Blood and the material basis for this effect. Extracellular microelectrode recordings were used to observe the effects of Dragon's Blood and various combinations of the three components (cochinchinenin A, cochinchinenin B, and Ioureirin B) extracted from Dragon's Blood on the discharge activities of wide dynamic range (WDR) neurons in spinal dorsal horn (SDH) of intact male Wistar rats evoked by electric stimulation at sciatic nerve. When the Hill's coefficients describing the dose-response relations of drugs were dif-ferent, based on the concept of dose equivalence, the equations of addillvity surfaces which can be applied to assess the interaction between three drugs were derived. Adopting the equations and Tal-larida's isobole equations used to assess the interaction between two drugs with dissimilar dose-response relations, the effects produced by various combinations of the three components in modulating the evoked discharge activities of WDR neurons were evaluated. Results showed that Dragon's Blood and its three components could inhibit the evoked discharge frequencies of WDR neurons in a concentration-dependent way. The Hill's coefficients describing dose-response relations of three components were different. Only the combined effect of cochinchinenin A, cochinchinenin B and Ioureirin B was similar to that of Dragons Blood. Furthermore, the combined effect was synergistic. This investigation demonstrated that through the synergistic interaction of the three components Dragon's Blood could interfere with the transmission and processing of pain signals in spinal dorsal horn. All these further proved that the combination of cochinchinenin A, cochinchinenin B, and Ioureirin B was the material basis for the analgesic effect of Dragon's Blood.

  19. Material basis for inhibition of Dragon’s Blood on evoked discharges of wide dynamic range neurons in spinal dorsal horn of rats

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    In vivo experiments were designed to verify the analgesic effect of Dragon’s Blood and the material basis for this effect. Extracellular microelectrode recordings were used to observe the effects of Dragon’s Blood and various combinations of the three components (cochinchinenin A, cochinchinenin B, and loureirin B) extracted from Dragon’s Blood on the discharge activities of wide dynamic range (WDR) neurons in spinal dorsal horn (SDH) of intact male Wistar rats evoked by electric stimulation at sciatic nerve. When the Hill’s coefficients describing the dose-response relations of drugs were dif-ferent, based on the concept of dose equivalence, the equations of additivity surfaces which can be applied to assess the interaction between three drugs were derived. Adopting the equations and Tal-larida’s isobole equations used to assess the interaction between two drugs with dissimilar dose-response relations, the effects produced by various combinations of the three components in modulating the evoked discharge activities of WDR neurons were evaluated. Results showed that Dragon’s Blood and its three components could inhibit the evoked discharge frequencies of WDR neurons in a concentration-dependent way. The Hill’s coefficients describing dose-response relations of three components were different. Only the combined effect of cochinchinenin A, cochinchinenin B and loureirin B was similar to that of Dragons Blood. Furthermore, the combined effect was synergistic. This investigation demonstrated that through the synergistic interaction of the three components Dragon’s Blood could interfere with the transmission and processing of pain signals in spinal dorsal horn. All these further proved that the combination of cochinchinenin A, cochinchinenin B, and loureirin B was the material basis for the analgesic effect of Dragon’s Blood.

  20. Material basis for inhibition of Dragon's Blood on evoked discharges of wide dynamic range neurons in spinal dorsal horn of rats.

    Science.gov (United States)

    Guo, Min; Chen, Su; Liu, Xiangming

    2008-11-01

    In vivo experiments were designed to verify the analgesic effect of Dragon's Blood and the material basis for this effect. Extracellular microelectrode recordings were used to observe the effects of Dragon's Blood and various combinations of the three components (cochinchinenin A, cochinchinenin B, and loureirin B) extracted from Dragon's Blood on the discharge activities of wide dynamic range (WDR) neurons in spinal dorsal horn (SDH) of intact male Wistar rats evoked by electric stimulation at sciatic nerve. When the Hill's coefficients describing the dose-response relations of drugs were different, based on the concept of dose equivalence, the equations of additivity surfaces which can be applied to assess the interaction between three drugs were derived. Adopting the equations and Tallarida's isobole equations used to assess the interaction between two drugs with dissimilar dose-response relations, the effects produced by various combinations of the three components in modulating the evoked discharge activities of WDR neurons were evaluated. Results showed that Dragon's Blood and its three components could inhibit the evoked discharge frequencies of WDR neurons in a concentration-dependent way. The Hill's coefficients describing dose-response relations of three components were different. Only the combined effect of cochinchinenin A, cochinchinenin B and loureirin B was similar to that of Dragons Blood. Furthermore, the combined effect was synergistic. This investigation demonstrated that through the synergistic interaction of the three components Dragon's Blood could interfere with the transmission and processing of pain signals in spinal dorsal horn. All these further proved that the combination of cochinchinenin A, cochinchinenin B, and loureirin B was the material basis for the analgesic effect of Dragon's Blood.

  1. fMRI activation during spike and wave discharges evoked by photic stimulation

    DEFF Research Database (Denmark)

    Moeller, Friederike; Siebner, Hartwig R; Ahlgrimm, Nils

    2009-01-01

    intermittent photic stimulation (IPS) in a 3 T MR scanner. PPR was elicited in 6 subjects, four diagnosed with idiopathic generalised epilepsy and two with tension-type headache. Because PPR is preceded by synchronization of cortical gamma oscillations, blood oxygenation level-dependent (BOLD) signal changes...

  2. Acoustic waves in transversely excited atmospheric CO2 laser discharges: effect on performance and reduction techniques

    CSIR Research Space (South Africa)

    von Bergmann, HM

    2008-08-01

    Full Text Available Results are presented on the influence of acoustic waves on the performance of high-repetition-rate TEA CO2 lasers. It is shown that acoustic waves generated inside the laser cavity lead to nonuniform discharges, resulting in a deterioration...

  3. INHIBITION OF BRAIN CHOLINESTERASE AND THE PHOTIC AFTER DISCHARGE OF FLASH EVOKED POTENTIALS PRODUCED BY CARBARYL IN LONG EVANS RATS.

    Science.gov (United States)

    Carbaryl is a widely used N-methyl carbamate pesticide that acts by inhibiting cholinesterases (ChE), which may lead to cholinergic toxicity. Flash evoked potentials (FEPs) are a neurophysiological response often used to detect central nervous system (CNS) changes following expos...

  4. Study of the Effect of Decrease in the Conductivity Ahead of a Shock Wave in a Glow-Discharge Plasma

    Science.gov (United States)

    Baryshnikov, A. S.; Basargin, I. V.; Bobashev, S. V.; Monakhov, N. A.; Popov, P. A.; Sakharov, V. A.; Chistyakova, M. V.

    2016-05-01

    The electrical conductivity of a glow-discharge plasma ahead of a shock wave moving perpendicularly to the discharge axis has been investigated using a double electric probe. The obtained results have shown that the interaction of the shock wave with the glow-discharge plasma is accompanied by a change in its conductivity in the entire investigated volume simultaneously.

  5. Simulation Study of the Relationship between Partial Discharge and Ultrahigh-Frequency Electromagnetic Wave in GIS

    Directory of Open Access Journals (Sweden)

    Wang Jiang

    2014-03-01

    Full Text Available When partial discharge occurs in Gas Insulated Switchgear (GIS with insulation defects, Ultrahigh-Frequency (UHF electromagnetic wave up to several MHz and GHz will be exited and propagate inside GIS cavity. This study, based on the propagation theory of electromagnetic waves in coaxial waveguide, performs simulation analysis of the relationship between PD pulse form and the exited UHF electromagnetic wave using Finite-Deferential Time-Domain (FDTD algorithm. First, we study the relationship of partial discharge magnitude and electric field strength of electromagnetic wave. It is found that the changes of partial discharge magnitude have little effect on electric field strength of electromagnetic wave at certain variation rate of PD pulse current. Next, we examine the relationship of variation rate of PD pulse current to electric field strength of electromagnetic wave. It is pointed out that, at a certain partial discharge magnitude, the two are approximately linearly related. Finally, we study the impact of variation rate of PD pulse current on higher mode components. Variation coefficient is used to analyze the proportion of higher mode components in electromagnetic wave. The proportion of higher mode components increases with increasing variation rate of PD pulse current.

  6. Drift waves in a high-density cylindrical helicon discharge

    DEFF Research Database (Denmark)

    Schröder, C.; Grulke, O.; Klinger, T.

    2005-01-01

    of the background plasma parameters. All experimentally observed features of the instability are found to be consistent with drift waves. A linear nonlocal numerical model for drift modes, based on the two-fluid description of a plasma, is used for comparison between the experimental observations and theory....... Comparing numerical and experimental frequencies, it is found that the experimentally observed frequencies are consistent with drift waves. The numerical results show that the high electron collision frequencies provide the strongest destabilization mechanism in the helicon plasma. (c) 2005 American...

  7. The Mechanical Analysis and Experimental Study of Shock Wave Effect of Electrical Discharge under Water In Filth Cleaning

    Institute of Scientific and Technical Information of China (English)

    Deng Qilin; Zhang Lei; Zhou Jinjin

    2004-01-01

    Filth adhering to metal pipes can be cleaned by shock wave generated by electrical discharge under water. The mechanism of shock wave effect of electrical discharge under water on filth cleaning is analyzed by building a mechanical model. A metal pipe coated with cement to simulate real filth is cleaned by using electrical discharge under water. The experimental results confirm the mechanical analysis and also show the technology of electrical discharge under water is an very effective method for filth cleaning.

  8. Analysis of partial discharge Ultrasonic wave characteristic on typical Defects in GIS

    Directory of Open Access Journals (Sweden)

    Yang Jing Gang

    2016-01-01

    Full Text Available For analyzing partial discharge ultrasonic wave characteristic on typical defects in SF6 gas insulation switchgear (GIS, a 110 kV GIS was taken as an object to design and simulate the typical partial discharge models in GIS. There are point electrode model on bus and cavity of GIS, floating electrode model, air interstice model in insulator, metal particle and iron core electromagnetic shock models. PD signals on different defects were thus detected with the ultrasonic method. The experimental results indicated that the ultrasonic signals of different defects showed different characteristics in waveform, amplitude and phase resolved partial discharge chart, which is helpful in PD pattern recognition for GIS.

  9. Measurements of Electric Field in a Nanosecond Pulse Discharge by 4-WAVE Mixing

    Science.gov (United States)

    Baratte, Edmond; Adamovich, Igor V.; Simeni Simeni, Marien; Frederickson, Kraig

    2017-06-01

    Picosecond four-wave mixing is used to measure temporally and Picosecond four-wave mixing is used to measure temporally and spatially resolved electric field in a nanosecond pulse dielectric discharge sustained in room air and in an atmospheric pressure hydrogen diffusion flame. Measurements of the electric field, and more precisely the reduced electric field (E/N) in the plasma is critical for determination rate coefficients of electron impact processes in the plasma, as well as for quantifying energy partition in the electric discharge among different molecular energy modes. The four-wave mixing measurements are performed using a collinear phase matching geometry, with nitrogen used as the probe species, at temporal resolution of about 2 ns . Absolute calibration is performed by measurement of a known electrostatic electric field. In the present experiments, the discharge is sustained between two stainless steel plate electrodes, each placed in a quartz sleeve, which greatly improves plasma uniformity. Our previous measurements of electric field in a nanosecond pulse dielectric barrier discharge by picosecond 4-wave mixing have been done in air at room temperature, in a discharge sustained between a razor edge high-voltage electrode and a plane grounded electrode (a quartz plate or a layer of distilled water). Electric field measurements in a flame, which is a high-temperature environment, are more challenging because the four-wave mixing signal is proportional to the to square root of the difference betwen the populations of N2 ground vibrational level (v=0) and first excited vibrational level (v=1). At high temperatures, the total number density is reduced, thus reducing absolute vibrational level populations of N2. Also, the signal is reduced further due to a wider distribution of N2 molecules over multiple rotational levels at higher temperatures, while the present four-wave mixing diagnostics is using spectrally narrow output of a ps laser and a high

  10. Time-frequency analysis of spike-wave discharges using a modified wavelet transform

    NARCIS (Netherlands)

    Bosnyakova, D.Y.; Gabova, A.; Kuznetsova, G.D.; Obukhov, Y.; Midzyanovskaya, I.S.; Salonin, D.V.; Rijn, C.M. van; Coenen, A.M.L.; Tuomisto, L.; Luijtelaar, E.L.J.M. van

    2006-01-01

    The continuous Morlet wavelet transform was used for the analysis of the time-frequency pattern of spike-wave discharges (SWD) as can be recorded in a genetic animal model of absence epilepsy (rats of the WAG/Rij strain). We developed a new wavelet transform that allows to obtain the time-frequency

  11. Ictal stimulus processing during spike-wave discharges in genetic epileptic rats

    NARCIS (Netherlands)

    Drinkenburg, W.H.I.M.; Schuurmans, M.L.E.J.; Coenen, A.M.L.; Vossen, J.M.H.; Luijtelaar, E.L.J.M. van

    2003-01-01

    In the present experiment it was investigated whether and to what extent auditory information processing is possible during the presence of spike-wave discharges in rats. To that end, WAG/Rij rats which are an animal model for absence epilepsy, were provided with cortical electrodes for the registra

  12. A Study of the Impulse Wave Discharged from the Exits of Two Parallel Tubes

    Institute of Scientific and Technical Information of China (English)

    Yong-Hun Kweon; Heuy-Dong Kim; Toshiaki Setoguchi; Toshiyuki Aoki

    2003-01-01

    The twin impulse wave leads to very complicated flow fields, such as Mach stem, spherical waves, and vortex ring. The twin impulse wave discharged from the exits of the two tubes placed in parallel is investigated to understand the detailed flow physics associated with the twin impulse wave, compared with those in a single impulse wave. In the current study, the merging phenomena and propagation characteristics of the impulse waves are investigated using a shock tube experiment and by numerical computations. The Harten-Yee's total variation diminishing (TVD) scheme is used to solve the unsteady two-dimensional compressible Euler equations. The Mach number Ms of incident shock wave is changed below 1.5 and the distance between two-parallel tubes, L/d,is changed from 1.2 to 4.0. In the shock tube experiment, the twin impulse waves are visualized by a Schlieren optical system for the purpose of validation of computational work. The results obtained show that on the symmetric axis between two-parallel tubes, the peak pressure produced by the twin impulse waves and its location strongly depend upon the distance between two-parallel tubes, L/d and the incident shock Mach number,Ms. The predicted Schlieren images represent the measured twin-impulse wave with a good accuracy.

  13. EEG Brain Wave Activity at Rest and during Evoked Attention in Children with Attention-Deficit/Hyperactivity Disorder and Effects of Methylphenidate.

    Science.gov (United States)

    Thomas, Bianca Lee; Viljoen, Margaretha

    2016-01-01

    The aim of this study was to assess baseline EEG brain wave activity in children with attention-deficit/hyperactivity disorder (ADHD) and to examine the effects of evoked attention and methylphenidate on this activity. Children with ADHD (n = 19) were tested while they were stimulant free and during a period in which they were on stimulant (methylphenidate) medication. Control subjects (n = 18) were tested once. EEG brain wave activity was tested both at baseline and during focussed attention. Attention was evoked and EEG brain wave activity was determined by means of the BioGraph Infiniti biofeedback apparatus. The main finding of this study was that control subjects and stimulant-free children with ADHD exhibited the expected reactivity in high alpha-wave activity (11-12 Hz) from baseline to focussed attention; however, methylphenidate appeared to abolish this reactivity. Methylphenidate attenuates the normal cortical response to a cognitive challenge. © 2016 S. Karger AG, Basel.

  14. Substantia nigra dopaminergic unit activity in behaving cats: effect of arousal on spontaneous discharge and sensory evoked activity.

    Science.gov (United States)

    Strecker, R E; Jacobs, B L

    1985-12-30

    Single-unit activity of dopaminergic neurons in the substantia nigra was recorded in freely moving cats during a variety of conditions designed to shed light on the hypotheses that these neurons are involved in the regulation of arousal-stress and/or selective attention. Both aversive and non-aversive arousing experimental conditions were used, including tail pinch, immersion of feet in ice-water, white noise, inaccessible food, feeding, grooming, inaccessible rats, and somatosensory stimulation. None of these conditions had an effect on tonic neuronal discharge rate. However, these neurons did exhibit brief excitatory and inhibitory responses to phasic auditory or visual stimuli presented when the cat was sitting quietly. These responses were dramatically attenuated if these stimuli were presented during the aforementioned conditions of behavioral arousal. This sharply contrasts with the inability of these same conditions to influence spontaneous discharge rate. The sensitivity of this neuronal sensory response to the concurrent behavioral condition supports the hypothesis that these neurons are involved in attentional processes or selective responding. The lack of responsiveness of these neurons to a variety of arousal/stress manipulations supports the hypothesis that dopaminergic neurons play a permissive, rather than an active, role in these processes.

  15. Nonlinear series resonance and standing waves in dual-frequency capacitive discharges

    Science.gov (United States)

    Wen, De-Qi; Kawamura, E.; Lieberman, M. A.; Lichtenberg, A. J.; Wang, You-Nian

    2017-01-01

    It is well-known that the nonlinear series resonance in a high frequency capacitive discharge enhances the electron power deposition and also creates standing waves which produce radially center-high rf voltage profiles. In this work, the dynamics of series resonance and wave effects are examined in a dual-frequency driven discharge, using an asymmetric radial transmission line model incorporating a Child law sheath. We consider a cylindrical argon discharge with a conducting electrode radius of 15 cm, gap length of 3 cm, with a base case having a 60 MHz high frequency voltage of 250 V and a 10 MHz low frequency voltage of 1000 V, with a high frequency phase shift {φ\\text{H}}=π between the two frequencies. For this phase shift there is only one sheath collapse, and the time-averaged spectral peaks of the normalized current density at the center are mainly centered on harmonic numbers 30 and 50 of the low frequency, corresponding to the first standing wave resonance frequency and the series resonance frequency, respectively. The effects of the waves on the series resonance dynamics near the discharge center give rise to significant enhancements in the electron power deposition, compared to that near the discharge edge. Adjusting the phase shift from π to 0, or decreasing the low frequency from 10 to 2 MHz, results in two or more sheath collapses, respectively, making the dynamics more complex. The sudden excitation of the perturbed series resonance current after the sheath collapse results in a current oscillation amplitude that is estimated from analytical and numerical calculations. Self-consistently determining the dc bias and including the conduction current is found to be important. The subsequent slow time variation of the high frequency oscillation is analyzed using an adiabatic theory.

  16. Discharge of a shock Wave from an Open End of a Tube

    Institute of Scientific and Technical Information of China (English)

    HideoKashimura; HiroyasuNakayama; 等

    2000-01-01

    When a pressure wave propagates along a constant area straight tube and reaches at the open end,an impulsive wave is emitted outwared from the tube exit toward the surrounding area and causes an impulsive noise like a sonic oom.In order to clarify the magnitude of an impulsive wave obtainde by the discharge of a weak shock wave from an open end of a tube in relation to the noise problem and the industrial devices,the experimental and numerical investigations have been carried out for various strength of a shock wave.A simple open end shock tuby with the flange at the tube exit was used and the numerical calculation using the TVD scheme was performed.The effective equations which concerns with the magnitude of an impulsive wave generated by the emission of a shock wave have been obtained from the procedure of the open end correction based on the aeroacoustic theory and the numerical results.The influence of open end correction length and the diameter of a flange on the magnitude of an impulsive wave has been discussed.

  17. Influence of deposited energy on shock wave induced by underwater pulsed current discharge

    Science.gov (United States)

    Li, Xian-Dong; Liu, Yi; Liu, Si-Wei; Li, Zhi-Yuan; Zhou, Gu-Yue; Li, Hua; Lin, Fu-Chang; Pan, Yuan

    2016-10-01

    In this paper, an integrated experimental system is established to study the influence of deposited energy on the intensity of the shock wave induced by underwater pulse discharge. Considering the time varying behavior of the arc, the calculation methods of the deposited energy into the plasma channel and the average arc resistance are proposed and presented. The effect of the breakdown process on the deposited energy and the shock wave is analyzed. It can be concluded that the shock wave intensity can be improved by depositing more energy in the first half oscillation period and increasing the arc resistance. It is also found that the energy deposition and the shock wave intensity are significantly influenced by the breakdown time delay and the shape of the initial plasma channel.

  18. SONIC SPEED AND SHOCK WAVE IN HIGH VELOCITY AERATED FLOWS FROM HIGH HEAD DISCHARGE STRUCTURES

    Institute of Scientific and Technical Information of China (English)

    Dong Zhi-yong

    2003-01-01

    The compressible characteristics in aerated flows at the high velocity of about 50m/s were analyzed. Based on the theory of compressible the relations between the sonic speed and shock wave in high-velocity aerated flow were theoretically deduced. And comparisons with measured data were made. The theoretical and experimental results show the sonic speed in aerated flow is merely of the order of several-dozen meters per second, and its minimum value is only 20m/s, which is far much less than that in water or air alone. So high subsonic flow, supersonic flow and transonic flow as well as compression wave, shock wave and expansion wave similarly to aerodnamics may be produced in high velocity aerated flow at the speed of the order of 50m/s. Hence the influences of these compressible characteristics on high head discharge structures can not be neglected, especially on super high dams over 200m high.

  19. Deltas, freshwater discharge, and waves along the Young Sound, NE Greenland.

    Science.gov (United States)

    Kroon, Aart; Abermann, Jakob; Bendixen, Mette; Lund, Magnus; Sigsgaard, Charlotte; Skov, Kirstine; Hansen, Birger Ulf

    2017-02-01

    A wide range of delta morphologies occurs along the fringes of the Young Sound in Northeast Greenland due to spatial heterogeneity of delta regimes. In general, the delta regime is related to catchment and basin characteristics (geology, topography, drainage pattern, sediment availability, and bathymetry), fluvial discharges and associated sediment load, and processes by waves and currents. Main factors steering the Arctic fluvial discharges into the Young Sound are the snow and ice melt and precipitation in the catchment, and extreme events like glacier lake outburst floods (GLOFs). Waves are subordinate and only rework fringes of the delta plain forming sandy bars if the exposure and fetch are optimal. Spatial gradients and variability in driving forces (snow and precipitation) and catchment characteristics (amount of glacier coverage, sediment characteristics) as well as the strong and local influence of GLOFs in a specific catchment impede a simple upscaling of sediment fluxes from individual catchments toward a total sediment flux into the Young Sound.

  20. Stimulated Electromagnetic Emission Indicator of Glow Plasma Discharges from Ionospheric HF Wave Transmissions with HAARP

    Science.gov (United States)

    Bernhardt, P. A.; Scales, W.; Briczinski, S. J.; Fu, H.; Mahmoudian, A.; Samimi, A.

    2012-12-01

    High power radio waves resonantly interact with to accelerate electrons for production of artificial aurora and plasma clouds. These plasma clouds are formed when the HF frequency is tuned near a harmonic of the electron cyclotron frequency. At a narrow band resonance, large electrostatic fields are produced below the F-layer and the neutral atmosphere breaks down with a glow plasma discharge. The conditions for this resonance are given by matching the pump wave frequency and wave-number with the sum of daughter frequencies and wave-numbers for several plasma modes. The most likely plasma mode that accelerates the electrons is the electron Bernstein wave in conjunction with an ion acoustic wave. Both upper hybrid and whistler mode waves are also possible sources of electron acceleration. To determine the plasma process for electron acceleration, stimulated electromagnetic emissions are measured using ground receivers in a north-south chain from the HAARP site. Recent observations have shown that broad band spectral lines downshifted from the HF pump frequency are observed when artificial plasma clouds are formed. For HF transmissions are the 2nd, 3rd, and 4th gyro harmonic, the downshifted indicators are found 500 Hz, 20 kHz, and 140 kHz, respectively, from the pump frequency. This Indicator Mode (IM) anticipates that a plasma layer will be formed before it is recorded with an ionosonde or optical imager.

  1. Charge mitigation techniques using glow and corona discharges for advanced gravitational wave detectors

    Energy Technology Data Exchange (ETDEWEB)

    Campsie, P; Cunningham, L; Hendry, M; Hough, J; Reid, S; Rowan, S; Hammond, G D, E-mail: p.campsie@physics.gla.ac.uk [SUPA , Institute for Gravitational Research, School of Physics and Astronomy, University of Glasgow, Glasgow, G12 8QQ (United Kingdom)

    2011-11-07

    Charging of silica test masses in gravitational wave detectors could potentially become a significant low-frequency noise source for advanced detectors. Charging noise has already been observed and confirmed in the GEO600 detector and is thought to have been observed in one of the LIGO detectors. In this paper, two charge mitigation techniques using glow and corona discharges were investigated to create repeatable and robust procedures. The glow discharge procedure was used to mitigate charge under vacuum and would be intended to be used in the instance where an optic has become charged while the detector is in operation. The corona discharge procedure was used to discharge samples at atmospheric pressure and would be intended to be used to discharge the detector optics during the cleaning of the optics. Both techniques were shown to reduce both polarities of surface charge on fused silica to a level that would not limit advanced LIGO. Measurements of the transmission of samples that had undergone the charge mitigation procedures showed no significant variation in transmission, at a sensitivity of {approx} 200 ppm, in TiO{sub 2}-doped Ta{sub 2}O{sub 5}/SiO{sub 2} multi-layer coated fused silica.

  2. The effects of antiepileptic drugs on estrogen-induced electrographic spike-wave discharge.

    Science.gov (United States)

    Julien, R M; Fowler, G W; Danielson, M G

    1975-05-01

    In locally anesthetized, paralyzed cats with bilateral conjugated estrogen (CE)-induced foci in sensory motor cortex, electrographic activity was characterized by 2 to 3 Hz spike and slow wave discharge. Commonly used anti-petit mal drugs (esthosuximide, trimethadione, acetazolamide and diazepam) all reduced CE-induced spike wave activity while diphenylhydantoin converted such activity into 9 to 12 Hz polyspike bursts separated by periods of interictal silence. Correlation appears to exist, therefore, between the ability of the drug to reduce CE-induced spike wave activity and its clinical utility in petit mal epilepsy. In addition to the above compounds, five drugs of less proven utility were evaluated. Of these, two benzodiazepine derivatives (clonazepam and clorazepate) were found to exert a potent and prolonged depressant action on CE-induced activity. The relation of CE to clinical petit mal epilepsy and the potential usefulness of CE as a laboratory model for the evaluation of anti-petit mal drugs are discussed.

  3. Causal hierarchy within the thalamo-cortical network in spike and wave discharges.

    Directory of Open Access Journals (Sweden)

    Anna E Vaudano

    Full Text Available BACKGROUND: Generalised spike wave (GSW discharges are the electroencephalographic (EEG hallmark of absence seizures, clinically characterised by a transitory interruption of ongoing activities and impaired consciousness, occurring during states of reduced awareness. Several theories have been proposed to explain the pathophysiology of GSW discharges and the role of thalamus and cortex as generators. In this work we extend the existing theories by hypothesizing a role for the precuneus, a brain region neglected in previous works on GSW generation but already known to be linked to consciousness and awareness. We analysed fMRI data using dynamic causal modelling (DCM to investigate the effective connectivity between precuneus, thalamus and prefrontal cortex in patients with GSW discharges. METHODOLOGY AND PRINCIPAL FINDINGS: We analysed fMRI data from seven patients affected by Idiopathic Generalized Epilepsy (IGE with frequent GSW discharges and significant GSW-correlated haemodynamic signal changes in the thalamus, the prefrontal cortex and the precuneus. Using DCM we assessed their effective connectivity, i.e. which region drives another region. Three dynamic causal models were constructed: GSW was modelled as autonomous input to the thalamus (model A, ventromedial prefrontal cortex (model B, and precuneus (model C. Bayesian model comparison revealed Model C (GSW as autonomous input to precuneus, to be the best in 5 patients while model A prevailed in two cases. At the group level model C dominated and at the population-level the p value of model C was approximately 1. CONCLUSION: Our results provide strong evidence that activity in the precuneus gates GSW discharges in the thalamo-(fronto cortical network. This study is the first demonstration of a causal link between haemodynamic changes in the precuneus -- an index of awareness -- and the occurrence of pathological discharges in epilepsy.

  4. Experimental investigation of the shock wave in a fast discharge with cylindrical geometry

    Energy Technology Data Exchange (ETDEWEB)

    Antsiferov, P. S.; Dorokhin, L. A. [Russian Academy of Sciences, Institute of Spectroscopy (Russian Federation)

    2013-08-15

    The work is devoted to the registration and the study of the properties of cylindrical shock waves generated in the fast discharge (dI/dt ∼ 10{sup 12} A/s) inside the ceramic tube (Al{sub 2}O{sub 3}) filled by argon at pressures of 100 and 300 Pa. The shock wave appears at the inner wall of the insulator and moves to the discharge axis with a velocity of about (3−4) × 10{sup 6} cm/s with subsequent cumulation. The plasma behind the front is heated enough to produce radiation in the vacuum ultraviolet (VUV) region, which makes it possible to study its structure by means of a pinhole camera with a microchannel plate detector. The time resolution of the registration system was 10 ns. The analysis of VUV spectra of the plasma shows that the electron temperature behind the shock wave front is about several eV; after the moment of cumulation, its temperature increases to 20–30 eV.

  5. Experimental investigation of the shock wave in a fast discharge with cylindrical geometry

    Science.gov (United States)

    Antsiferov, P. S.; Dorokhin, L. A.

    2013-08-01

    The work is devoted to the registration and the study of the properties of cylindrical shock waves generated in the fast discharge ( dI/ dt ˜ 1012 A/s) inside the ceramic tube (Al2O3) filled by argon at pressures of 100 and 300 Pa. The shock wave appears at the inner wall of the insulator and moves to the discharge axis with a velocity of about (3-4) × 106 cm/s with subsequent cumulation. The plasma behind the front is heated enough to produce radiation in the vacuum ultraviolet (VUV) region, which makes it possible to study its structure by means of a pinhole camera with a microchannel plate detector. The time resolution of the registration system was 10 ns. The analysis of VUV spectra of the plasma shows that the electron temperature behind the shock wave front is about several eV; after the moment of cumulation, its temperature increases to 20-30 eV.

  6. Hollow radial electron density profiles in surface wave discharges. An inside job?

    Science.gov (United States)

    Jimenez-Diaz, Manuel; Rahimi, Sara; Carbone, Emile A. D.; Dijk, Jan Van

    2013-09-01

    In many microwave excited plasmas, there is a part of the discharge (tube) hidden from optical access e.g. because of the metal parts that cover it; it is the region where the transformation occurs between the EM modes found in the (metal) waveguide to modes in the plasma (waveguide). Because in most of cases optical access is not an option here, studies of this region remain scarce. Regardless of this, it is a well-known fact that the discharge tube can easily break due to the high temperatures inside the launcher of surfaguide discharges, which means the temperature is higher there than in other regions of the plasma. In this work, we use a 2D model to show how the inner region changes for increasing power absorbed and electromagnetic wave frequency. The shaping of the EM coupling into the plasma region by the cavity is explored as well. We discuss when the hollow radial profiles for the electron density appear in a surfaguide plasma, and how they are related to the radial inhomogeneity of the EM fields and the plasma properties (e.g. gas temperature). All these results were obtained using the modeling platform Plasimo. Supported by the Dutch Technology Foundation (STW Project Nos. 10497 and 10744) and by the Energy Research Center of the Netherlands (ECN).

  7. Depression of the photic after discharge of flash evoked potentials by physostigmine, carbaryl and propoxur, and the relationship to inhibition of brain cholinesterase.

    Science.gov (United States)

    Mwanza, Jean-Claude; Finley, Dana; Spivey, Christopher L; Graff, Jaimie E; Herr, David W

    2008-01-01

    The effects of N-methyl carbamate pesticides on the photic after discharge (PhAD) of flash evoked potentials (FEPs) and the relationship between inhibition of brain cholinesterase (ChE) activity and the PhAD were evaluated. FEPs were recorded in Long Evans rats treated with physostigmine (s.c.) 0, 0.05, 0.1, 0.2 or 0.3mg/kg (free base), in an ascorbic acid/saline vehicle, carbaryl (p.o.) 0, 1, 3, 10, 30, 50 or 75 mg/kg, or propoxur (p.o.) 0, 0.3, 3, 10, 20, 30, or 40 mg/kg in a corn oil vehicle. Physostigmine served as positive control based on literature data. Early (e.g. peak N(36)) and late FEP components (peak N(166) and PhAD) are related to the initial retino-geniculate afferent volley and higher cortical processing of visual information, respectively. Compared to controls, the PhAD duration decreased following treatment with 0.1 and 0.3mg/kg physostigmine, 7 5 mg/kg carbaryl or 30 mg/kg propoxur. Lesser changes were noted in FEP amplitudes or peak latencies. Treatment with 0.2 or 0.3 mg/kg physostigmine increased peak N(36) latency. Peak N(166) latency increased only following exposure to 40 mg/kg propoxur. None of the compounds altered peak N(36) or N(166) amplitudes. Hypothermia was observed at doses greater than 0.05 mg/kg physostigmine, at 30 or 50 mg/kg carbaryl, and after treatment with 10, 20 or 40 mg/kg propoxur. Inhibition of brain ChE activity occurred at dosages greater than 0.05 mg/kg physostigmine, 1mg/kg carbaryl, and 0.3 mg/kg propoxur. Linear regression analysis indicated that the decrease in PhAD duration correlated with decrease in brain ChE activity. The results indicate that at 30 min after treatment, inhibition of brain ChE activity did not affect cortical processing of the input from the retino-geniculate volley (evidenced by unaltered peak N(36) amplitude). However, the data suggest that disruption of cortical processing of visual signals related to FEP late components, as indicated by depression of the PhAD, was related to inhibition

  8. Ultrafast traveling wave dominates the electric organ discharge of Apteronotus leptorhynchus: an inverse modelling study.

    Science.gov (United States)

    Shifman, Aaron R; Longtin, André; Lewis, John E

    2015-10-30

    Identifying and understanding the current sources that give rise to bioelectric fields is a fundamental problem in the biological sciences. It is very difficult, for example, to attribute the time-varying features of an electroencephalogram recorded from the head surface to the neural activity of specific brain areas; model systems can provide important insight into such problems. Some species of fish actively generate an oscillating (c. 1000 Hz) quasi-dipole electric field to communicate and sense their environment in the dark. A specialized electric organ comprises neuron-like cells whose collective signal underlies this electric field. As a step towards understanding the detailed biophysics of signal generation in these fish, we use an anatomically-detailed finite-element modelling approach to reverse-engineer the electric organ signal over one oscillation cycle. We find that the spatiotemporal profile of current along the electric organ constitutes a travelling wave that is well-described by two spatial Fourier components varying in time. The conduction velocity of this wave is faster than action potential conduction in any known neuronal axon (>200 m/s), suggesting that the spatiotemporal features of high-frequency electric organ discharges are not constrained by the conduction velocities of spinal neuron pathways.

  9. Cholinesterase inhibition and depression of the photic after discharge of flash evoked potentials following acute or repeated exposures to a mixture of carbaryl and propoxur.

    Science.gov (United States)

    Mwanza, Jean-Claude; Lyke, Danielle F; Hertzberg, Richard C; Haber, Lynne; Kohrman-Vincent, Melissa; Li, Ruosha; Pan, Yi; Lyles, Robert H; Simmons, Jane Ellen; Macmillan, Denise K; Zehr, R Dan; Swank, Adam E; Herr, David W

    2012-06-01

    Previously, we reported that acute treatment with propoxur or carbaryl decreased the duration of the photic after discharge (PhAD) of flash evoked potentials (FEPs). In the current studies, we compared the effects of acute or repeated exposure to a mixture of carbaryl and propoxur (1:1.45 ratio; propoxur:carbaryl) on the duration of the PhAD and brain ChE activity in Long Evans rats. Animals were exposed (po) either to a single dose (0, 3, 10, 45 or 75 mg/kg), or 14 daily dosages (0, 3, 10, 30, 45 mg/kg), of the mixture. Acute and repeated treatment with 3mg/kg (or greater) of the mixture produced dose-related inhibition of brain ChE activity. Compared to controls, the PhAD duration decreased after acute administration of 75 mg/kg or repeated treatment with 30 mg/kg of the mixture. The linear relationship between the percent of control brain ChE activity and the PhAD duration was similar for both exposure paradigms. Dose-response models for the acute and repeated exposure data did not differ for brain ChE activity or the duration of the PhAD. Repeated treatment with the mixture resulted in slightly less (13-22%) erythrocyte ChE inhibition than acute exposure. Both acute and repeated treatment resulted in dose-additive results for the PhAD duration and less than dose-additive responses (6-16%) for brain ChE activity for the middle range of dosages. Acute treatment resulted in greater than dose-additive erythrocyte ChE inhibition (15-18%) at the highest dosages. In contrast, repeated treatment resulted in less than dose-additive erythrocyte ChE inhibition (16-22%) at the middle dosages. Brain and plasma levels of propoxur and carbaryl did not differ between the acute and repeated dosing paradigms. In summary, a physiological measure of central nervous system function and brain ChE activity had similar responses after acute or repeated treatment with the carbamate mixture, and brain ChE showed only small deviations from dose-additivity. Erythrocyte ChE activity had

  10. Interferometric and schlieren characterization of the plasmas and shock wave dynamics during laser-triggered discharge in atmospheric air

    Science.gov (United States)

    Wei, Wenfu; Li, Xingwen; Wu, Jian; Yang, Zefeng; Jia, Shenli; Qiu, Aici

    2014-08-01

    This paper describes our efforts to reveal the underlying physics of laser-triggered discharges in atmospheric air using a Mach-Zehnder interferometer and schlieren photography. Unlike the hemispherical shock waves that are produced by laser ablation, bell-like morphologies are observed during laser-triggered discharges. Phase shifts are recovered from the interferograms at a time of 1000 ns by the 2D fast Fourier transform method, and then the values of the refractive index are deduced using the Abel inversion. An abundance of free electrons is expected near the cathode surface. The schlieren photographs visualize the formation of stagnation layers at ˜600 ns in the interaction zones of the laser- and discharge-produced plasmas. Multiple reflected waves are observed at later times with the development of shock wave propagations. Estimations using the Taylor-Sedov self-similar solution indicated that approximately 45.8% and 51.9% of the laser and electrical energies are transferred into the gas flow motions, respectively. Finally, numerical simulations were performed, which successfully reproduced the main features of the experimental observations, and provided valuable insights into the plasma and shock wave dynamics during the laser-triggered discharge.

  11. Unilateral and bilateral cortical resection: Effects on spike-wave discharges in a genetic absence epilepsy model

    NARCIS (Netherlands)

    Scicchitano, F.; Rijn, C.M. van; Luijtelaar, E.L.J.M. van

    2015-01-01

    Research Question Recent discoveries have challenged the traditional view that the thalamus is the primary source driving spike-and-wave discharges (SWDs). At odds, SWDs in genetic absence models have a cortical focal origin in the deep layers of the perioral region of the somatosensory cortex. The

  12. BRAIN CHOLINESTERASE INHIBITION PRODUCED BY PROPOXUR AND DEPRESSION OF THE PHOTIC AFTER DISCHARGE OF FLASH EVOKED POTENTIALS IN LONG EVANS RATS.

    Science.gov (United States)

    Propoxur is a widely used N-methyl carbamate pesticide that acts by inhibiting cholinesterases (ChE), which may lead to cholinergic toxicity. Flash evoked potentials (FEPs) are a neurophysiological response following stimulation of the visual system with flashes of light. They ar...

  13. Voluntary Control of Epileptiform Spike-Wave Discharges in Awake Rats.

    Science.gov (United States)

    Taylor, Jeremy A; Rodgers, Krista M; Bercum, Florencia M; Booth, Carmen J; Dudek, F Edward; Barth, Daniel S

    2017-06-14

    Genetically inherited absence epilepsy in humans is typically characterized by brief (seconds) spontaneous seizures, which involve spike-wave discharges (SWDs) in the EEG and interruption of consciousness and ongoing behavior. Genetic (inbred) models of this disorder in rats have been used to examine mechanisms, comorbidities, and antiabsence drugs. SWDs have also been proposed as models of complex partial seizures (CPSs) following traumatic brain injury (post-traumatic epilepsy). However, the ictal characteristics of these rat models, including SWDs and associated immobility, are also prevalent in healthy outbred laboratory rats. We therefore hypothesized that SWDs are not always associated with classically defined absence seizures or CPSs. To test this hypothesis, we used operant conditioning in male rats to determine whether outbred strains, Sprague Dawley and Long-Evans, and/or the inbred WAG/Rij strain (a rat model of heritable human absence epilepsy) could exercise voluntary control over these epileptiform events. We discovered that both inbred and outbred rats could shorten the duration of SWDs to obtain a reward. These results indicate that SWD and associated immobility in rats may not reflect the obvious cognitive/behavioral interruption classically associated with absence seizures or CPSs in humans. One interpretation of these results is that human absence seizures and perhaps CPSs could permit a far greater degree of cognitive capacity than often assumed and might be brought under voluntary control in some cases. However, these results also suggest that SWDs and associated immobility may be nonepileptic in healthy outbred rats and reflect instead voluntary rodent behavior unrelated to genetic manipulation or to brain trauma.SIGNIFICANCE STATEMENT Our evidence that inbred and outbred rats learn to control the duration of spike-wave discharges (SWDs) suggests a voluntary behavior with maintenance of consciousness. If SWDs model mild absence seizures and

  14. The pacemaker role of thalamic reticular nucleus in controlling spike-wave discharges and spindles

    Science.gov (United States)

    Fan, Denggui; Liao, Fucheng; Wang, Qingyun

    2017-07-01

    Absence epilepsy, characterized by 2-4 Hz spike-wave discharges (SWDs), can be caused by pathological interactions within the thalamocortical system. Cortical spindling oscillations are also demonstrated to involve the oscillatory thalamocortical rhythms generated by the synaptic circuitry of the thalamus and cortex. This implies that SWDs and spindling oscillations can share the common thalamocortical mechanism. Additionally, the thalamic reticular nucleus (RE) is hypothesized to regulate the onsets and propagations of both the epileptic SWDs and sleep spindles. Based on the proposed single-compartment thalamocortical neural field model, we firstly investigate the stimulation effect of RE on the initiations, terminations, and transitions of SWDs. It is shown that the activations and deactivations of RE triggered by single-pulse stimuli can drive the cortical subsystem to behave as the experimentally observed onsets and self-abatements of SWDs, as well as the transitions from 2-spike and wave discharges (2-SWDs) to SWDs. In particular, with increasing inhibition from RE to the specific relay nucleus (TC), rich transition behaviors in cortex can be obtained through the upstream projection path, RE → TC → Cortex . Although some of the complex dynamical patterns can be expected from the earlier single compartment thalamocortical model, the effect of brain network topology on the emergence of SWDs and spindles, as well as the transitions between them, has not been fully investigated. We thereby develop a spatially extended 3-compartment coupled network model with open-/closed-end connective configurations, to investigate the spatiotemporal effect of RE on the SWDs and spindles. Results show that the degrees of activations of RE 1 can induce the rich spatiotemporal evolution properties including the propagations from SWDs to spindles within different compartments and the transitions between them, through the RE 1 → TC 1 → Cortex 1 and Cortex 1 → Cortex 2

  15. Modeling auditory evoked brainstem responses to transient stimuli

    DEFF Research Database (Denmark)

    Rønne, Filip Munch; Dau, Torsten; Harte, James

    2012-01-01

    A quantitative model is presented that describes the formation of auditory brainstem responses (ABR) to tone pulses, clicks and rising chirps as a function of stimulation level. The model computes the convolution of the instantaneous discharge rates using the “humanized” nonlinear auditory...... of tone-pulse evoked wave-V latency with frequency but underestimates the level dependency of the tone-pulse as well as click-evoked latency values. Furthermore, the model correctly predicts the nonlinear wave-V amplitude behavior in response to the chirp stimulation both as a function of chirp sweeping...... rate and level. Overall, the results support the hypothesis that the pattern of ABR generation is strongly affected by the nonlinear and dispersive processes in the cochlea....

  16. Brain correlates of spike and wave discharges in GLUT1 deficiency syndrome.

    Science.gov (United States)

    Vaudano, Anna Elisabetta; Olivotto, Sara; Ruggieri, Andrea; Gessaroli, Giuliana; De Giorgis, Valentina; Parmeggiani, Antonia; Veggiotti, Pierangelo; Meletti, Stefano

    2017-01-01

    To provide imaging biomarkers of generalized spike-and-wave discharges (GSWD) in patients with GLUT1 deficiency syndrome (GLUT1DS). Eighteen GLUT1DS patients with pathogenetic mutation in SLC2A1 gene were studied by means of Video-EEG simultaneously recorded with functional MRI (VideoEEG-fMRI). A control group of sex and age-matched patients affected by Genetic Generalized Epilepsy (GGE) with GSWD were investigated with the same protocol. Within and between groups comparison was performed as appropriated. For GLUT1DS, correlations analyses between the contrast of interest and the main clinical measurements were provided. EEG during fMRI revealed interictal GSWD in 10 GLUT1DS patients. Group-level analysis showed BOLD signal increases at the premotor cortex and putamen. With respect to GGE, GLUT1DS patients demonstrated increased neuronal activity in the putamen, precuneus, cingulate cortex, SMA and paracentral lobule. Whole-brain correlation analyses disclosed a linear relationship between the GSWD-related BOLD changes and the levels of glycorrhachia at diagnosis over the sensory-motor cortex and superior parietal lobuli. The BOLD dynamics related to GSWD in GLUT1DS are substantially different from typical GGE showing the former an increased activity in the premotor-striatal network and a decrease in the thalamus. The revealed hemodynamic maps might represent imaging biomarkers of GLUT1DS, being potentially useful for a precocious diagnosis of this genetic disorder.

  17. Genetic threshold hypothesis of neocortical spike-and-wave discharges in the rat: an animal model of petit mal epilepsy.

    Science.gov (United States)

    Vadász, C; Carpi, D; Jando, G; Kandel, A; Urioste, R; Horváth, Z; Pierre, E; Vadi, D; Fleischer, A; Buzsáki, G

    1995-02-27

    Neocortical high-voltage spike-and-wave discharges (HVS) in the rat are an animal model of petit mal epilepsy. Genetic analysis of total duration of HVS (s/12 hr) in reciprocal F1 and F2 hybrids of F344 and BN rats indicated that the phenotypic variability of HVS cannot be explained by a simple, monogenic Mendelian model. Biometrical analysis suggested the presence of additive, dominance, and sex-linked-epistatic effects, buffering maternal influence, and heterosis. High correlation was observed between average duration (s/episode) and frequency of occurrence of spike-and-wave episodes (n/12 hr) in parental and segregating generations, indicating that common genes affect both duration and frequency of the spike-and-wave pattern. We propose that both genetic and developmental-environmental factors control an underlying quantitative variable, which, above a certain threshold level, precipitates HVS discharges. These findings, together with the recent availability of rat DNA markers for total genome mapping, pave the way to the identification of genes that control the susceptibility of the brain to spike-and-wave discharges.

  18. Genetic threshold hypothesis of neocortical spike-and-wave discharges in the rat: An animal model of petit mal epilepsy

    Energy Technology Data Exchange (ETDEWEB)

    Vadasz, C.; Fleischer, A. [Nathan Kline Inst. for Psychiatric Research, Orangeburg, NY (United States); Carpi, D.; Jando, G. [State Univ. of New Jersey, Newark, NJ (United States)] [and others

    1995-02-27

    Neocortical high-voltage spike-and-wave discharges (HVS) in the rat are an animal model of petit mal epilepsy. Genetic analysis of total duration of HVS (s/12 hr) in reciprocal F1 and F2 hybrids of F344 and BN rats indicated that the phenotypic variability of HVS cannot be explained by simple, monogenic Mendelian model. Biometrical analysis suggested the presence of additive, dominance, and sex-linked-epistatic effects, buffering maternal influence, and heterosis. High correlation was observed between average duration (s/episode) and frequency of occurrence of spike-and-wave episodes (n/12 hr) in parental and segregating generations, indicating that common genes affect both duration and frequency of the spike-and-wave pattern. We propose that both genetic and developmental - environmental factors control an underlying quantitative variable, which, above a certain threshold level, precipitates HVS discharges. These findings, together with the recent availability of rat DNA markers for total genome mapping, pave the way to the identification of genes that control the susceptibility of the brain to spike-and-wave discharges. 67 refs., 3 figs., 5 tabs.

  19. Discharge conditions for CW and pulse-modulated surface-wave plasmas in low-temperature sterilization

    Energy Technology Data Exchange (ETDEWEB)

    Xu, L [Department of Electrical and Electronic Engineering, Faculty of Engineering, Shizuoka University, 3-5-1 Johoku, Hamamatsu 432-8561 (Japan); Terashita, F [Department of Electrical and Electronic Engineering, Faculty of Engineering, Shizuoka University, 3-5-1 Johoku, Hamamatsu 432-8561 (Japan); Nonaka, H [Department of Electrical and Electronic Engineering, Faculty of Engineering, Shizuoka University, 3-5-1 Johoku, Hamamatsu 432-8561 (Japan); Ogino, A [Department of Electrical and Electronic Engineering, Faculty of Engineering, Shizuoka University, 3-5-1 Johoku, Hamamatsu 432-8561 (Japan); Nagata, T [Department of Microbiology and Immunology, Hamamatsu University School of Medicine, 1-20-1 Handa-yama, Hamamatsu 431-3192 (Japan); Koide, Y [Department of Microbiology and Immunology, Hamamatsu University School of Medicine, 1-20-1 Handa-yama, Hamamatsu 431-3192 (Japan); Nanko, S [Nissin Inc., 10-7 Kamei-cho, Takarazuka 665-0047 (Japan); Kurawaki, I [GMA Co. Ltd., 3898-1, Asaba, Fukuroi, 437-1101 (Japan); Nagatsu, M [Department of Electrical and Electronic Engineering, Faculty of Engineering, Shizuoka University, 3-5-1 Johoku, Hamamatsu 432-8561 (Japan)

    2006-01-07

    The discharge conditions required for low-temperature plasma sterilization were investigated using low-pressure surface-wave plasma (SWP). The discharge conditions for both continuous wave (CW) and pulse-modulated SWPs in low-temperature sterilization of Geobacillus stearothermophilus with a population of 1.5 x 10{sup 6} and 3.0 x 10{sup 6} were studied by varying the microwave input power from 500 W to 3 kW, and the effective plasma treatment time from 40 to 300 s. Results showed that sterilization was possible in a shorter treatment time using a higher microwave power for both CW and pulse-modulated SWPs. Pulse-modulated SWPs gave effective sterilization at a temperature roughly 10 to 20 deg. C below that of CW SWPs under the same average microwave power.

  20. Discharge conditions for CW and pulse-modulated surface-wave plasmas in low-temperature sterilization

    Science.gov (United States)

    Xu, L.; Terashita, F.; Nonaka, H.; Ogino, A.; Nagata, T.; Koide, Y.; Nanko, S.; Kurawaki, I.; Nagatsu, M.

    2006-01-01

    The discharge conditions required for low-temperature plasma sterilization were investigated using low-pressure surface-wave plasma (SWP). The discharge conditions for both continuous wave (CW) and pulse-modulated SWPs in low-temperature sterilization of Geobacillus stearothermophilus with a population of 1.5 × 106 and 3.0 × 106 were studied by varying the microwave input power from 500 W to 3 kW, and the effective plasma treatment time from 40 to 300 s. Results showed that sterilization was possible in a shorter treatment time using a higher microwave power for both CW and pulse-modulated SWPs. Pulse-modulated SWPs gave effective sterilization at a temperature roughly 10 to 20 °C below that of CW SWPs under the same average microwave power.

  1. Comparison between off-resonance and electron Bernstein waves heating regime in a microwave discharge ion source

    Energy Technology Data Exchange (ETDEWEB)

    Castro, G.; Di Giugno, R.; Miracoli, R. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Universita degli Studi di Catania, Dipartimento di Fisica e Astronomia, V. S. Sofia 64, 95123 Catania (Italy); Mascali, D. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); CSFNSM, Viale A. Doria 6, 95125 Catania (Italy); Romano, F. P. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); CNR-IBAM Via Biblioteca 4, 95124 Catania (Italy); Celona, L.; Gammino, S.; Lanaia, D.; Ciavola, G. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Serafino, T. [CSFNSM, Viale A. Doria 6, 95125 Catania (Italy); Di Bartolo, F. [Universita di Messina, Ctr. da Papardo-Sperone, 98100 Messina (Italy); Gambino, N. [INFN- Laboratori Nazionali del Sud, via S. Sofia 62, 95123 Catania (Italy); Universita degli Studi di Catania, Dipartimento di Fisica e Astronomia, V. S. Sofia 64, 95123 Catania (Italy); IET-Institute of Energy Technology, LEC-Laboratory for Energy Conversion, ETH Zurich, Sonneggstrasse 3, CH-8092 Zurich (Switzerland)

    2012-02-15

    A microwave discharge ion source (MDIS) operating at the Laboratori Nazionali del Sud of INFN, Catania has been used to compare the traditional electron cyclotron resonance (ECR) heating with an innovative mechanisms of plasma ignition based on the electrostatic Bernstein waves (EBW). EBW are obtained via the inner plasma electromagnetic-to-electrostatic wave conversion and they are absorbed by the plasma at cyclotron resonance harmonics. The heating of plasma by means of EBW at particular frequencies enabled us to reach densities much larger than the cutoff ones. Evidences of EBW generation and absorption together with X-ray emissions due to high energy electrons will be shown. A characterization of the discharge heating process in MDISs as a generalization of the ECR heating mechanism by means of ray tracing will be shown in order to highlight the fundamental physical differences between ECR and EBW heating.

  2. [Topographic aspects of visual evoked potentials recorded after flash-pattern stimulation in normal subjects].

    Science.gov (United States)

    Samson-Dollfus, D; Parain, D; Menard, J F; Layet, A; Nehili, F; Dreano, E

    1986-02-01

    Visual evoked responses have been recorded on 14 leads placed on the scalp. They were localised on the central, parietal, temporal and occipital regions. The common reference was linked-ears. The stimulus consisted of a flash pattern. The size of the pattern and of each square was respectively of 20 degrees and 30 min. The stimulation of the total visual field had evoked two families of curves. One of these types of curves was posterior (occipital, temporal and parietal) and consisted in a positive, negative, positive wave (100, 136, 200 msec on average) and the second type was localised on the central leads and much more rhythmic than the posterior response. The initial complex (negative, positive, negative, positive: 70, 92, 120, 178 msec) was followed by a slow after-discharge. The half-field stimulation evoked a P100 component on the contralateral posterior leads, but this P100 was less prominent on the ipsilateral posterior leads. The modifications were particularly evident at the level of the temporal posterior electrodes. This P100 component was the only wave to be modified by half-field visual stimulation. The posterior N136 and P200 wave and all the rhythmic central response were exactly the same with half or total visual field stimulation. The results have obviously shown that the different waves of the visual evoked responses are not coming from the same sources. The interpretation of multichannel evoked recordings was therefore very difficult.

  3. Space and time structure of helium pulsed surface-wave discharges at intermediate pressures (5-50 Torr)

    Science.gov (United States)

    Hamdan, Ahmad; Valade, Fabrice; Margot, Joëlle; Vidal, François; Matte, Jean-Pierre

    2017-01-01

    In this paper, the ignition and development of a plasma created by pulsed surface wave discharges (PSWDs) was experimentally investigated using time-resolved imaging techniques and optical spectroscopy in helium at intermediate gas pressures between 5 and 50 Torr. We found that the ionization front moves at a few km s-1 during the ignition phase and decreases to hundreds of m s-1 after only some tens of µs. Once the plasma has reached a sufficient length, a standing wave pattern is observed in the light emission of the discharge. We attribute its formation to the reflection of the surface wave on the ionization front, which results in a pattern of nodes and antinodes. We have also determined the time and space evolution of the gas temperature. It is shown that the gas temperature increases from the room temperature value to a plateau at several hundreds of degrees over a short time (typically 100 µs). These results supports those obtained by light emission imaging and also show that the standing wave pattern does not affect the gas temperature.

  4. Role of on-board discharge in shock wave drag reduction and plasma cloaking

    Institute of Scientific and Technical Information of China (English)

    Qiu Xiao-Ming; Tang De-Li; Sun Ai-Ping; Liu Wan-Dong; Zeng Xue-Jun

    2007-01-01

    In the present paper, a physical model is proposed for reducing the problem of the drag reduction of an attached bow shock around the nose of a high-speed vehicle with on-board discharge, to the problem of a balance between the magnetic pressure and gas pressure of plane shock of a partially ionized gas consisting of the environmental gas around the nose of the vehicle and the on-board discharge-produced plasma. The relation between the shock strength and the discharge-induced magnetic pressure is studied by means of a set of one-fluid, hydromagnetic equations reformed for the present purpose, where the discharge-induced magnetic field consists of the electron current (produced by the discharge)-induced magnetic field and the partially ionized gas flow-induced one. A formula for the relation between the above parameters is derived. It shows that the discharge-induced magnetic pressure can minimize the shock strength,successfully explaining the two recent experimental observations on attached bow shock mitigation and elimination in a supersonic flow during on-board discharge [Phys. Plasmas 9 (2002) 721 and Phys. Plasmas 7 (2000) 1345]. In addition,the formula implies that the shock elimination leaves room for a layer of higher-density plasma rampart moving around the nose of the vehicle, being favourable to the plasma radar cloaking of the vehicle. The reason for it is expounded.

  5. Propagation characteristics of dust$-$acoustic waves in presence of a floating cylindrical object in the DC discharge plasma

    CERN Document Server

    Choudhary, Mangilal; Bandyopadhyay, P

    2016-01-01

    The experimental observation of the self$-$excited dust acoustic waves (DAWs) and its propagation characteristics in the absence and presence of a floating cylindrical object are investigated. The experiments are carried out in a direct current (DC) glow discharge dusty plasma in the background of argon gas. Dust particles are found levitated at the interface of plasma and cathode sheath region. The DAWs are spontaneously excited in the dust medium and found to propagate in the direction of ion drift (along the gravity) above a threshold discharge current at lower pressure. The excitation of such low frequency wave is a result of the ion--dust streaming instability in the dust cloud. The characteristics of the propagating dust acoustic wave get modified in presence of a floating cylindrical object of radius larger than the dust Debye length. Instead of propagating in the vertical direction, the DAWs are found to propagate obliquely in presence of the floating object (kept either vertically or horizontally). I...

  6. A continuous microwave discharge maintained by two crossing millimeter-wave beams in hydrogen and argon: numerical simulation and experiment

    Science.gov (United States)

    Chernov, V. V.; Gorbachev, A. M.; Vikharev, A. L.; Radishev, D. B.; Kozlov, A. V.

    2016-12-01

    The results of numerical simulation of a continuous microwave discharge in two crossing wave beams of 30 GHz radiation in a mixture of hydrogen and argon are presented. The model describes the steady state of the gas discharge in Ar-H2-H through the self-consistent solution of the following equations: Maxwell’s equations, the electron balance equation, the transport of hydrogen atoms in the ternary mixture, the heat conduction equation and the equation of state of ideal gas. In Maxwell’s equations the effect of the plasma is taken into account through the conduction current. It is assumed that the generation of electrons occurs due to ionization processes and their loss occurs due to processes of electron-ion recombination and ambipolar diffusion. In the model the heat transfer is considered to be due to gas thermal conductivity and transfer of dissociation energy through the flow of hydrogen atoms. The gas pressure is assumed to be constant, and convection effects are neglected. The other approximations and reductions used in the model are discussed. The adequacy of the obtained model is confirmed by comparing the calculation results to experimental data. For comparison the distributions of gas temperature along the substrate in the center of the discharge and the atomic hydrogen flow to the substrate are used. The temperature is experimentally obtained through the analysis of the optical emission of the C2 Swan line. The atomic hydrogen flow to the substrate is measured from the etching of graphite samples imbedded into the substrate. The possibility of obtaining large-area uniform plasma layers in hydrogen with a small addition of methane is predicted. The applications of such gas discharge are discussed.

  7. A flowing plasma model to describe drift waves in a cylindrical helicon discharge

    CERN Document Server

    Chang, L; Cormac, C S

    2011-01-01

    A two-fluid model developed originally to describe wave oscillations in the vacuum arc centrifuge, a cylindrical, rapidly rotating, low temperature and confined plasma column, is applied to interpret plasma oscillations in a RF generated linear magnetised plasma (WOMBAT), with similar density and field strength. Compared to typical centrifuge plasmas, WOMBAT plasmas have slower normalised rotation frequency, lower temperature and lower axial velocity. Despite these differences, the two-fluid model provides a consistent description of the WOMBAT plasma configuration and yields qualitative agreement between measured and predicted wave oscillation frequencies with axial field strength. In addition, the radial profile of the density perturbation predicted by this model is consistent with the data. Parameter scans show that the dispersion curve is sensitive to the axial field strength and the electron temperature, and the dependence of oscillation frequency with electron temperature matches the experiment. These r...

  8. Submillimeter-wave rotational spectra of DNC in highly excited vibrational states observed in an extended negative glow discharge

    Science.gov (United States)

    Amano, T.

    2011-05-01

    Rotational transitions of DNC have been observed in the submillimeter-wave region in an extended negative glow discharge in a gas mixture of CD 4 and N 2. The dissociative recombination reaction of DCND + with electrons is thought to be a dominant channel to produce DNC in highly excited vibrational states. The vibrational temperature for the ν3 vibrational mode is found to be about 4000 K, and the rotational lines in levels up to (0 0 8) are observed. The rotational and centrifugal distortion constants are determined for these states along with those for the (1 0 0) state. The measurement accuracy is high enough to determine some higher order vibration-rotation interaction constants.

  9. Fast wave direct electron heating in advanced inductive and ITER baseline scenario discharges in DIII-D

    Energy Technology Data Exchange (ETDEWEB)

    Pinsker, R. I.; Jackson, G. L.; Luce, T. C.; Politzer, P. A. [General Atomics, PO Box 85608, San Diego, California 92186-5608 (United States); Austin, M. E. [University of Texas at Austin, Austin, Texas 78712 (United States); Diem, S. J.; Kaufman, M. C.; Ryan, P. M. [Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Doyle, E. J.; Zeng, L. [University of California Los Angeles, Los Angeles, California 90095 (United States); Grierson, B. A.; Hosea, J. C.; Nagy, A.; Perkins, R.; Solomon, W. M.; Taylor, G. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States); Maggiora, R.; Milanesio, D. [Politecnico di Torino, Dipartimento di Elettronica, Torino (Italy); Porkolab, M. [Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States); Turco, F. [Columbia University, New York, New York 10027 (United States)

    2014-02-12

    Fast Wave (FW) heating and electron cyclotron heating (ECH) are used in the DIII-D tokamak to study plasmas with low applied torque and dominant electron heating characteristic of burning plasmas. FW heating via direct electron damping has reached the 2.5 MW level in high performance ELMy H-mode plasmas. In Advanced Inductive (AI) plasmas, core FW heating was found to be comparable to that of ECH, consistent with the excellent first-pass absorption of FWs predicted by ray-tracing models at high electron beta. FW heating at the ∼2 MW level to ELMy H-mode discharges in the ITER Baseline Scenario (IBS) showed unexpectedly strong absorption of FW power by injected neutral beam (NB) ions, indicated by significant enhancement of the D-D neutron rate, while the intended absorption on core electrons appeared rather weak. The AI and IBS discharges are compared in an effort to identify the causes of the different response to FWs.

  10. Determining the Probability Distribution of Hillslope Peak Discharge Using an Analytical Solution of Kinematic Wave Time of Concentration

    Science.gov (United States)

    Baiamonte, Giorgio; Singh, Vijay P.

    2016-04-01

    Hillslope hydrology is fundamental for understanding the flood phenomenon and for evaluating the time of concentration. The latter is a key variable for predicting peak discharge at the basin outlet and for designing urban infrastructure facilities. There have been a multitude of studies on the hydrologic response at the hillslope scale, and the time of concentration has been derived for different approaches. One approach for deriving hillslope response utilizes, in a distributed form, the differential equations of unsteady overland flow, specifically developed at the hydrodynamic scale, in order to account for the spatial heterogeneity of soil characteristics, topography, roughness and vegetation cover on the hillslope. Therefore, this approach seemingly mimics the complete hydraulics of flow. However, the very complex patterns generated by spatial heterogeneity can cause considerable error in the prediction even by very sophisticated models. Another approach that directly operates at the hillslope scale is by averaging over the hillslope the soil hydraulics, the topography, and the roughness characteristics. A physically-based lumped model of hillslope response was first proposed by Horton (1938), under the assumption that the flow regime is intermediate between laminar and turbulent regimes (transitional flow regime), by applying the mass conservation equation to the hillslope as a whole and by using the kinematic wave assumption for the friction slope (Singh, 1976, 1996). Robinson et al. (1995) and Robinson and Sivapalan (1996) generalized Horton's approach, suggesting an approximate solution of the overland flow equation that is valid for all flow regimes. Agnese et al. (2001) derived an analytical solution of a nonlinear storage model of hillslope response that is valid for all flow regimes, and the associated time of concentration. Recently, the well-known kinematic wave equation for computing the time of concentration for impervious surfaces has been

  11. Effects of remacemide and its metabolite Fpl-12495 on spike-wave discharges, EEG, and behavior in rats with absence epilepsy

    NARCIS (Netherlands)

    Luijtelaar, E.L.J.M. van; Coenen, A.M.L.

    1995-01-01

    Anticonvulsant drugs may or may not be effective against generalized absence epilepsy. Carbamazepine and phenytoin aggravate spike-wave discharges (SWD) whereas valproate and benzodiazepines reduce SWD. The effects of the new anticonvulsant remacemide on SWD are unknown, which prompted us to

  12. Effects of remacemide and its metabolite FPL 12495 on spike-wave discharges, electroencephalogram and behaviour in rats with absence epilepsy

    NARCIS (Netherlands)

    Luijtelaar, E.L.J.M. van; Coenen, A.M.L.

    1995-01-01

    The effects of the anti-convulsant drug remacemide and one of its active metabolites FPL 12495 were examined in a genetic model for generalized absence epilepsy, the WAG/Rij strain of rats. Number, mean and total duration of spike-wave discharges were measured following oral administration of

  13. Wave-like free-standing NiCo2O4 cathode for lithium-oxygen battery with high discharge capacity

    Science.gov (United States)

    Shen, Chen; Wen, Zhaoyin; Wang, Fan; Rui, Kun; Lu, Yan; Wu, Xiangwei

    2015-10-01

    A novel free-standing air electrode for Li-O2 battery with a wave-like microstructure is designed and synthesized through a facile electrochemical deposition process. Interconnected NiCo2O4 nanosheets with planes grown almost parallel to the surface of Ni foam build up continues porous catalytic surface with open space for the growth of Li2O2 discharge product. Li-O2 battery with the synthesized cathode delivers a high discharge capacity of 7004 mAh g-1 at 40 mA g-1 with a charge potential lower than 3.6 V (vs. Li/Li+), and significantly lower impedance compared to conventional electrode. Flower-like Li2O2 particles with a large size are observed as discharge products, consisting with the high discharge capacity. The unique wave-like microstructure and DMSO-based electrolyte with a high-doner-number are proposed to be responsible for the high discharge capacity, and the formation of large size Li2O2 discharge products. In addition, the electrode also exhibits stable cycle performance up to 100 cycles at the current density of 100 mA g-1 due to the robust composition and microstructure of the free-standing design.

  14. Elevations and discharges produced by a simulated flood wave on the lower Sabine River, Louisiana and Texas, caused by a theoretical dam failure

    Science.gov (United States)

    Neely, Braxtel L.; Stiltner, Gloria J.

    1979-01-01

    The Toledo Bend Reservoir is located on the lower Sabine River between Louisiana and Texas. Two mathematical models were coupled to calculate the flood wave that would result from the theoretical failure of 25 percent of Toledo Bend Dam and route the wave downstream to Orange, Tex. Computations assumed failure (1) at the peak of the 100-year flood when discharge of the Sabine River is 102,000 cubic feet per second and (2) when the average discharge is 10,000 cubic feet per second. Two techniques were used in the dam-break model. The method of characteristics was used to propagate the shock wave following dam failure. The linear implicit finite-difference solution was used to route the flood wave following shock wave dissipation. The magnitude of the flow was determined for Burkeville, Bon Wier, Ruliff, and Orange, Tex., along the lower Sabine River. For these sites, respectively, the following peak elevations were calculated: 119, 82, 31, and 13 feet for the 100-year flood and 110, 75, 27, and 9 feet for the average discharge. (Woodard-USGS)

  15. First results with a surface conversion H ion source based on helicon wave mode-driven plasma discharge

    Energy Technology Data Exchange (ETDEWEB)

    Tarvainen, Ollie A [Los Alamos National Laboratory; Geros, Ernest [Los Alamos National Laboratory; Rouleau, Gary [Los Alamos National Laboratory; Zaugg, Thomas J [Los Alamos National Laboratory

    2008-01-01

    The currently employed converter-type negative ion source at Los Alamos Neutron Science Center (LANSCE) is based on cesium enhanced surface production of H{sup -} ion beams in a filament-driven discharge. The extracted H{sup -} beam current is limited by the achievable plasma density, which depends primarily on the electron emission current from the filaments. The emission current can be increased by increasing the filament temperature but, unfortunately, this leads not only to shorter filament lifetime but also to an increase in metal evaporation from the filament, which degrades the performance of the H{sup -} conversion surface. In order to overcome these limitations we have designed and tested a prototype of a surface conversion H{sup -} ion source, based on excitation of helicon plasma wave mode with an external antenna. The source has been operated with and without cesium injection. An H{sup -} beam current of over 12 mA has been transported through the low energy beam transport of the LANSCE ion source test stand. The results of these experiments and the effects of different source parameters on the extracted beam current are presented. The limitations of the source prototype are discussed and future improvements are proposed based on the experimental observations.

  16. Comparison of H2 and He carbon cleaning mechanisms in extreme ultraviolet induced and surface wave discharge plasmas

    CERN Document Server

    Dolgov, A; Rachimova, T; Kovalev, A; Vasilyeva, A; Lee, C J; Krivtsun, V M; Yakushev, O; Bijkerk, F

    2013-01-01

    Cleaning of contamination of optical surfaces by amorphous carbon (a-C) is highly relevant for extreme ultraviolet (EUV) lithography. We have studied the mechanisms for a-C removal from a Si surface. By comparing a-C removal in a surface wave discharge (SWD) plasma and an EUV-induced plasma, the cleaning mechanisms for hydrogen and helium gas environments were determined. The C-atom removal per incident ion was estimated for different sample bias voltages and ion fluxes. It was found that H2 plasmas generally had higher cleaning rates than He plasmas: up to seven times higher for more negatively biased samples in EUV induced plasma. Moreover, for H2, EUV induced plasma was found to be 2-3 times more efficient at removing carbon than the SWD plasma. It was observed carbon removal during exposure to He is due to physical sputtering by He+ ions. In H2, on the other hand, the increase in carbon removal rates is due to chemical sputtering. This is a new C cleaning mechanism for EUV-induced plasma, which we call "E...

  17. Characteristics of Spherical Shock Wave and Circular Pulse Jet Generated by Discharge of Propagating Shock Wave at Open End of Tube

    Institute of Scientific and Technical Information of China (English)

    Tsukasa Irie; Tsuyoshi Yasunobu; Hideo Kashimura; Toshiaki Setoguchi; Kazuyasu Matsuo

    2003-01-01

    When the shock wave propagating in the straight circular tube reaches at the open end, the impulsive wave is generated by the emission of a shock wave from an open end, and unsteady pulse jet is formed near the open end behind the impulsive wave under the specific condition. The pulse jet transits to spherical shock wave with the increase in the strength of shock wave. The strength is dependent on the Mach number of shock wave, which attenuates by propagation distance from the open end. In this study, the mechanism of generating the unsteady pulse jet, the characteristics of the pressure distribution in the flow field and the emission of shock wave from straight circular tube which has the infinite flange at open end are analyzed numerically by the TVD method. Strength of spherical shock wave, relation of shock wave Mach number, distance decay of spherical shock wave and directional characteristics are clarified.

  18. The Realization of Low Loop Voltage Start-up of HT-7 Tokamak Discharge with the Assistance of Lower Hybrid Wave

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Low voltage start-up was realized in HT-7 discharges under the assistance of lower hybrid (LH) waves. The use of a strong LH wave, which can change its N// spectrum in a large range of several milliseconds, made the loop voltage for start-up reduce from around 20 V to less than 5 V. It means that the electric field for HT-7 start-up decreases from 2.5~3 V/m to 0.6 V/m.Some physical phenomena such as the consumption of magnetic flux in start-up phase and the radiation from the initial plasma were observed in this kind of low voltage start-up discharges.

  19. Binocularity in the little owl, Athene noctua. II. Properties of visually evoked potentials from the Wulst in response to monocular and binocular stimulation with sine wave gratings.

    Science.gov (United States)

    Porciatti, V; Fontanesi, G; Raffaelli, A; Bagnoli, P

    1990-01-01

    Visually evoked potentials (VEPs) have been recorded from the Wulst surface of the little owl, Athene noctua, in response to counterphase-reversal of sinusoidal gratings with different contrast, spatial frequency and mean luminance, presented either monocularly or binocularly. Monocular full-field stimuli presented to either eye evoked VEPs of similar amplitude, waveform and latency. Under binocular viewing, VEPs approximately doubled in amplitude without waveform changes. VEPs with similar characteristics could be obtained in response to stimulation of the contralateral, but not ipsilateral, hemifield. These results suggest that a 50% recrossing occurs in thalamic efferents and that different ipsilateral and contralateral regions converge onto the same Wulst sites. The VEP amplitude progressively decreased with increase of the spatial frequency beyond 2 cycles/degree, and the high spatial frequency cut-off (VEP acuity) was under binocular viewing (8 cycles/degree) higher than under monocular (5 cycles/degree) viewing (200 cd/m2, 45% contrast). The VEP acuity increased with increase in the contrast and decreased with reduction of the mean luminance. The binocular gain in both VEP amplitude and VEP acuity was largest at the lowest luminance levels. Binocular VEP summation occurred in the medium-high contrast range. With decreased contrast, both monocular and binocular VEPs progressively decreased in amplitude and tended to the same contrast threshold. The VEP contrast threshold depended on the spatial frequency (0.6-1.8% in the range 0.12-2 cycles/degree). Binocular VEPs often showed facilitatory interaction (binocular/monocular amplitude ratio greater than 2), but the binocular VEP amplitude did not change either by changing the stimulus orientation (horizontal vs. vertical gratings) or by inducing different retinal disparities.(ABSTRACT TRUNCATED AT 250 WORDS)

  20. Tuning the afterglow plasma composition in Ar/N2/O2 mixtures: characteristics of a flowing surface-wave microwave discharge system

    Science.gov (United States)

    Kutasi, Kinga; Noël, Cédric; Belmonte, Thierry; Guerra, Vasco

    2016-10-01

    A self-consistent kinetic model is used to study the possibility of tuning the plasma composition in the afterglow of a flowing surface-wave microwave discharge by the different discharge and system parameters in the case of 90%Ar-10%(N2-O2) and N2-O2 mixtures. The afterglow system consists of a 0.5 cm diameter quartz tube of 50 cm in length—where the discharge is generated and the early-afterglow develops—and an afterglow reactor. The plasma composition is studied at the end of the discharge plasma column and at the reactor inlet as a function of the N2:O2 ratio for selected conditions, which are set with the system parameters and are illustrated in the experimental set-up. The validity of the model used is proven by the agreement of the calculated atomic densities with those measured by mass spectrometry. Due to the pressure drop along the tube, the position of the discharge (which also defines the lengths of the early-afterglow, t aft) and the discharge pressure (p dis) can be set with the position of the wave coupler—surfatron—along the tube at a constant gas flow rate (which defines the pressure in the reactor, p reac). It is shown that the relative densities of species at the end of plasma column, which constitute the initial condition for the afterglow, depend on the discharge pressure. Therefore, at a constant gas flow rate with the position of the surfatron the plasma composition in the reactor is changing due to the variation of both the p dis and t aft. The evolution of the plasma composition is also studied when both the surfatron’s position and the gas flow rate are changed, realizing conditions (i) with the same p dis, and different t aft and p reac, and (ii) with the same t aft, and different p dis and p reac. Comparing the N2-O2 binary and the ternary mixtures, it is shown that the atomic densities obtained in the binary mixtures can be reproduced in ternary mixtures with different N2:O2 ratios. Furthermore, according to the spectra

  1. Rational design for SPAC to counter wash-away by waves and discharge waster; Nami to hosuiryu ni yoru senkutsu taisakuko SPAC no goriteki sekkei

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, T.; Ikeno, M. [Central Research Institute of Electric Power Industry, Tokyo (Japan); Ujiie, H.; Yamauchi, I. [Tohoku Electric Power Co. Inc., Sendai (Japan)

    1995-03-05

    Investigations were made as to how to design an SPAC (Spreading Armor Coat) for the prevention of wash-away from landfill-protected shores by warm water discharge. In this method, the sandy sea bottom in front of the discharge outlet is dredged and a stone layer is placed therein, and the spread of the layer forms an armor coat. This method is advantageous in that it requires less stone and less dredging than others. In the experiment, a discharge outlet model was used, and data were collected concerning the spread of the stone layer, etc. Findings are to be stated below. The deployment width of the stone layer is to be determined in view of the coverage of the junction slope sharing an angle of repose of 20 degrees with the wash-away width. In case the discharged current drifts under attacks by tall waves coming in obliquely, some allowance needs be added to the SPAC width in consideration of the drifting. A drift may be evaluated by some empirical formulae now available. For the prevention of sand from being drawn out through between the stones after the stone layer deployment, pebbles (1/3 of the stone in diameter) should be mingled with the stones, which will narrow the gap to 5% from 20%, the latter being the percentage with stones only. Pebbles work effectively when they are placed on the dredge-formed slope in the SPAC deployed area. 8 refs., 16 figs., 1 tab.

  2. Proprioceptive evoked gamma oscillations

    DEFF Research Database (Denmark)

    Arnfred, Sidse M; Hansen, Lars Kai; Parnas, Josef;

    2007-01-01

    A proprioceptive stimulus consisting of a weight change of a handheld load has recently been shown to elicit an evoked potential. Previously, somatosensory gamma oscillations have only been evoked by electrical stimuli. We conjectured that a natural proprioceptive stimulus also would be able...

  3. Experimental Verification on Remote Detectability of Concealed Radioactive Material Based on the Plasma Discharge Delay Time using High-Power Millimeter-Wave

    Science.gov (United States)

    Kim, Dongsung; Yu, Dongho; Sawant, Ashwini; Choe, Mun Seok; Lee, Ingeun; Choi, Eunmi

    2016-10-01

    We experimentally demonstrate a remote detection method of a radioactive source by plasma breakdown using high-power millimeter-wave source, gyrotron. A number of free electrons near the radioactive source are much higher than those of without the radioactive source (roughly 10 particles/cm3) owing to the interaction of air molecules and strong gamma rays generated by radioactive material. The RF wave beam is focused in ambient air, and the plasmas discharge occurs involving random delay time which means a time interval between the RF wave and a fluorescent light caused by the plasma. We observed that the delay time decreased significantly due to the high density of free electrons in Ar plasma with an existence of Co60 radioactive material. This technique of delay time measurement shows 1000 times more sensitive than a method of detectable mass equation to identify the existence of radioactive source remotely. It is the first experimental verification of radioactive material detection using a high power gyrotron. This study shows that a remote detection of radioactive material based on analysis of precise delay time measurement could be feasible by using a high power millimeter/THz wave gyrotron. NRF-2013R1A1A2061062, NRF-2012-Global Ph.D. Fellowship Program.

  4. Plasma parameters in the vicinity of the quartz window of a low pressure surface wave discharge produced in O2

    DEFF Research Database (Denmark)

    Nakao, S.; Stamate, Eugen; Sugai, H.

    2007-01-01

    Plasma parameters in the vicinity of the dielectric window of a low density, microwave discharge produced in 0, at 915 N/FHz are investigated by a spherical probe and optical emission spectroscopy while the microwave field distribution is measured by a spectrum analyzer. The electron energy...

  5. Global assessment of heat wave magnitudes from 1901 to 2010 and implications for the river discharge of the Alps.

    Science.gov (United States)

    Zampieri, Matteo; Russo, Simone; di Sabatino, Silvana; Michetti, Melania; Scoccimarro, Enrico; Gualdi, Silvio

    2016-11-15

    Heat waves represent one of the most significant climatic stressors for ecosystems, economies and societies. A main topic of debate is whether they have increased or not in intensity and/or their duration due to the observed climate change. Firstly, this is because of the lack of reliable long-term daily temperature data at the global scale; secondly, because of the intermittent nature of such phenomena. Long datasets are required to produce a reliable and meaningful assessment. In this study, we provide a global estimate of heat wave magnitudes based on the three most appropriate datasets currently available, derived from models and observations (i.e. the 20th Century Reanalyses from NOAA and ECMWF), spanning the last century and before. The magnitude of the heat waves is calculated by means of the Heat Wave Magnitude Index daily (HWMId), taking into account both duration and amplitude. We compare the magnitude of the most severe heat waves occurred across different regions of the world and we discuss the decadal variability of the larger events since the 1850s. We concentrate our analysis from 1901 onwards, where all datasets overlap. Our results agree with other studies focusing on heat waves that have occurred in the recent decades, but using different data. In addition, we found that the percentage of global area covered by heat wave exceeding a given magnitude has increased almost three times, in the last decades, with respect to that measured in the early 20th century. Finally, we discuss the specific implications of the heat waves on the river runoff generated in the Alps, for which comparatively long datasets exist, affecting the water quality and availability in a significant portion of the European region in summer.

  6. Experimental verification of the vaporization's contribution to the shock waves generated by underwater electrical wire explosion under micro-second timescale pulsed discharge

    Science.gov (United States)

    Han, Ruoyu; Zhou, Haibin; Wu, Jiawei; Clayson, Thomas; Ren, Hang; Wu, Jian; Zhang, Yongmin; Qiu, Aici

    2017-06-01

    This paper studies pressure waves generated by exploding a copper wire in a water medium, demonstrating the significant contribution of the vaporization process to the formation of shock waves. A test platform including a pulsed current source, wire load, chamber, and diagnostic system was developed to study the shock wave and optical emission characteristics during the explosion process. In the experiment, a total of 500 J was discharged through a copper wire load 0.2 mm in diameter and 4 cm in length. A water gap was installed adjacent to the load so that the current was diverted away from the load after breakdown occurred across the water gap. This allows the electrical energy injection into the load to be interrupted at different times and at different stages of the wire explosion process. Experimental results indicate that when the load was bypassed before the beginning of the vaporization phase, the measured peak pressure was less than 2.5 MPa. By contrast, the peak pressure increased significantly to over 6.5 MPa when the water gap broke down after the beginning of the vaporization phase. It was also found that when bypassing the load after the voltage peak, similar shock waves were produced to those from a non-bypassed load. However, the total optical emission of these bypassed loads was at least an order of magnitude smaller. These results clearly demonstrate that the vaporization process is vital to the formation of shock waves and the energy deposited after the voltage collapse may only have a limited effect.

  7. On the use of click-evoked electric brainstem responses in audiological diagnosis. IV. Interaural latency differences (wave V) in cochlear hearing loss.

    Science.gov (United States)

    Rosenhamer, H J; Lindström, B; Lundborg, T

    1981-01-01

    Interaural latency differences (ILDs) of wave V of the brainstem electric response (BSER) were studied (1) in 20 normal-hearing subjects at 90, 80, 60 and 40 dB HL click level, (2) in 22 patients with symmetrical cochlear hearing loss at 90 dB HL, corresponding to 45-80 dB SL, and (3) in 45 patients with asymetrical cochlear hearing loss with interaural recruitment, at 90 dB HL on one hand and at a click sensation level corresponding to 90 dB HL in the poorer ear (range 10-75 dB SL) on the other hand. In the normal hearing group the ILDs did not exceed 0.2 ms except in one case at 40 dB HL (0.3 ms). In the symmetrical cochlear loss group the ILD did not exceed 0.2 ms in any patient. In the asymmetrical cochlear loss group the ILD at 90 dB HL exceeded 0.2 ms in 12 cases, but only in four cases after correction for pure tone hearing loss at 4 kHz by 0.1 for each 10 dB above 50 dB HL; at equal sensation levels the ILDs were all zero or negative meaning that the wave V latency was shorter on stimulation of the poorer ear. Assuming ILD to be a valid discriminator between cochlear and retrocochlear lesions, the corrected ILD at equal click hearing levels (90 dB HL), with the critical value set at 0.2 ms, thus gave a 9% false-positive rate whereas the ILS at equal sensation levels, with the critical value set at zero, gave no false-positives. It still remains to be shown that the latter criterion will not increase the number of false-negative results in retrocochlear lesions.

  8. Pancreatitis - discharge

    Science.gov (United States)

    Chronic pancreatitis - discharge; Pancreatitis - chronic - discharge; Pancreatic insufficiency - discharge; Acute pancreatitis - discharge ... You were in the hospital because you have pancreatitis. This is a swelling of the pancreas. You ...

  9. Stereotactic radiosurgery - discharge

    Science.gov (United States)

    Gamma knife - discharge; Cyberknife - discharge; Stereotactic radiotherapy - discharge; Fractionated stereotactic radiotherapy - discharge; Cyclotrons - discharge; Linear accelerator - discharge; Lineacs - ...

  10. Idiopathic generalised epilepsies with 3 Hz and faster spike wave discharges: a population-based study with evaluation and long-term follow-up in 71 patients.

    Science.gov (United States)

    Siren, Auli; Eriksson, Kai; Jalava, Heli; Kilpinen-Loisa, Päivi; Koivikko, Matti

    2002-09-01

    For several years we have been following patients with intractable, childhood-onset idiopathic generalised epilepsies with > or = 3 Hz spike-wave discharges. Our need to find explanations for their intractability was the starting point for this study. We were interested in identifying characteristics, which would predict intractability; evaluating how these patients were treated and whether polytherapy was useful. We identified patients with > or = 3 Hz spike-wave discharges by reviewing EEG reports recorded between 1983 and 1992. Data were collected from medical records and through personal interviews. We identified 82 patients with tentative idiopathic generalised epilepsy. Eleven were excluded. Thirty-eight patients had childhood absence epilepsy, 18 had juvenile absence epilepsy, 13 had juvenile myoclonic epilepsy and two had eyelid myoclonia with absences: 89.5, 78, 38 and 0% of the patients in each group, respectively, had been seizure free for more than 2 years. Twenty percent of the patients had intractable seizures. All intractable patients with juvenile absence epilepsy had rhythmic, random eyelid blinking and generalised tonic-clonic seizures. A history of more than ten generalised tonic-clonic seizures was associated with intractability in juvenile myoclonic patients. Monotherapy with ethosuximide or valproate resulted in seizure control in 65% of patients. Seventeen patients (24%) were treated with polytherapy, six achieved remission. These six patients had childhood absence epilepsy and juvenile absence epilepsy. Positive outcome was found in childhood absence epilepsy and juvenile absence epilepsy. Intractable seizures were more frequent among patients with juvenile myoclonic epilepsy. None of them benefited from polytherapy with conventional anti-epileptic drugs.

  11. Changes of brainstem auditory and somatosensory evoked

    Institute of Scientific and Technical Information of China (English)

    Yang Jian

    2000-01-01

    Objective: to investigate the characteristics and clinical value of evoked potentials in late infantile form of metachromatic leukodystrophy. Methods: Brainstem auditory, and somatosensory evoked potentials were recorded in 6 patients, and compared with the results of CT scan. Results: All of the 6 patients had abnormal results of BAEP and MNSEP. The main abnormal parameters in BAEP were latency prolongation in wave I, inter-peak latency prolongation in Ⅰ-Ⅲ and Ⅰ-Ⅴ. The abnormal features of MNSEP were low amplitude and absence of wave N9, inter-Peak latency prolongation in Ng-N13 and N13-N20, but no significant change of N20 amplitude. The results also revealed that abnormal changes in BAEP and MNSEP were earlier than that in CT. Conclusion: The detection of BAEP and MNSEP in late infantile form of metachromatic leukodystrophy might early reveal the abnormality of conductive function in nervous system and might be a useful method in diagnosis.

  12. Modeling auditory evoked potentials to complex stimuli

    DEFF Research Database (Denmark)

    Rønne, Filip Munch

    The auditory evoked potential (AEP) is an electrical signal that can be recorded from electrodes attached to the scalp of a human subject when a sound is presented. The signal is considered to reflect neural activity in response to the acoustic stimulation and is a well established clinical...... clinically and in research towards using realistic and complex stimuli, such as speech, to electrophysiologically assess the human hearing. However, to interpret the AEP generation to complex sounds, the potential patterns in response to simple stimuli needs to be understood. Therefore, the model was used...... to simulate auditory brainstem responses (ABRs) evoked by classic stimuli like clicks, tone bursts and chirps. The ABRs to these simple stimuli were compared to literature data and the model was shown to predict the frequency dependence of tone-burst ABR wave-V latency and the level-dependence of ABR wave...

  13. Evoked acoustic emission

    DEFF Research Database (Denmark)

    Elberling, C; Parbo, J; Johnsen, N J;

    1985-01-01

    Stimulated acoustic emissions were recorded in response to tonal stimuli at 60 dB p.e. SPL in a small group of normal-hearing adults. Power spectral analysis reveals that the evoked activity from each ear contains energy in preferential frequency bands and the change of stimulus frequency has onl...

  14. Evoked acoustic emission

    DEFF Research Database (Denmark)

    Elberling, C; Parbo, J; Johnsen, N J;

    1985-01-01

    Stimulated acoustic emissions were recorded in response to tonal stimuli at 60 dB p.e. SPL in a small group of normal-hearing adults. Power spectral analysis reveals that the evoked activity from each ear contains energy in preferential frequency bands and the change of stimulus frequency has only...

  15. Proprioceptive evoked gamma oscillations

    DEFF Research Database (Denmark)

    Arnfred, S.M.; Hansen, Lars Kai; Parnas, J.;

    2007-01-01

    to evoke gamma oscillations. EEG was recorded using 64 channels in 14 healthy subjects. In each of three runs a stimulus of 100 g load increment in each hand was presented in 120 trials. Data were wavelet transformed and runs collapsed. Inter-trial phase coherence (ITPC) was computed as the best measure...

  16. Observation and characterization of the effect of electron cyclotron waves on toroidal rotation in EAST L-mode discharges

    Science.gov (United States)

    Chen, Jun; Hu, Ruiji; Lyu, Bo; Wang, Fudi; Wang, Xiaojie; Xu, Handong; Li, Yingying; Fu, Jia; Yin, Xianghui; Wu, Dajun; Liu, Fukun; Zang, Qing; Liu, Haiqing; Shi, Yuejiang; Mao, Shifeng; Yu, Yi; Wang, Baonian; Ye, Minyou; Shen, Yongcai; EAST Team

    2017-10-01

    The change in the toroidal rotation of plasma caused by electron cyclotron wave (ECW) injection has been observed in EAST. It is found that the response of the rotation is similar for all possible ECW toroidal injection angles. The core toroidal rotation velocity increases in the co-current direction along with a rise in the plasma temperature and stored energy. The profile of the electron temperature, ion temperature and toroidal rotation velocity gradually become peaked. The change in toroidal rotation in the core increases with the ECW injection power. Different behavior is observed when the ECWs are injected into low hybrid current drive (LHCD) target plasmas, where the electron temperature and rotation profile become peaked, while the ion temperature profile flattens after ECW injection, suggesting different transport characteristics in energy and momentum.

  17. Selecting and evoking innovators

    DEFF Research Database (Denmark)

    Kanstrup, Anne Marie; Christiansen, Ellen

    2006-01-01

    The practical undertaking of selecting users to work as innovators and of evoking their creative potential is crucial, but underexposed in the literature on user involvement in design. This paper reports findings from a recent case of user-driven innovation, the FEEDBACK-project, where the authors...... prepared for and conducted selection of and collaboration with innovators. The outcome was successful in the sense that the innovators produced excellent foundation for conceptual interaction design by creating mock-ups and explanations incarnating their preferences, attitudes and habits. By referring...... to theories of learning we try to explain how our way of working with selection and evoking of innovators has contributed to this positive result and how our approach to user-driven innovation can be regarded as a way to combine democracy and creativity in design....

  18. Capacitor discharge engineering

    CERN Document Server

    Früngel, Frank B A

    1976-01-01

    High Speed Pulse Technology, Volume III: Capacitor Discharge Engineering covers the production and practical application of capacitor dischargers for the generation and utilization of high speed pulsed of energy in different forms. This nine-chapter volume discusses the principles of electric current, voltage, X-rays, gamma rays, heat, beams of electrons, neutrons and ions, magnetic fields, sound, and shock waves in gases and liquids. Considerable chapters consider the applications of capacitor discharges, such as impulse hardening of steel, ultrapulse welding of precision parts, X-ray flash t

  19. Validity of actinometry to monitor oxygen atom concentration in microwave discharges created by surface wave in O2-N2 mixtures

    Science.gov (United States)

    Granier, A.; Chéreau, D.; Henda, K.; Safari, R.; Leprince, P.

    1994-01-01

    The validity of actinometry to monitor oxygen atom concentration in O2-N2 microwave discharges created by surface wave is investigated. The plasma is created with a gas flow in a quartz tube of inner diameter 16 mm at pressures in the Torr range. First, it is shown that the reliability of actinometry can be deduced from the longitudinal profile of the actinometry signal. Second, absolute concentrations of oxygen atoms are estimated from the experimental actinometry signal and agree satisfactorily with concentrations simultaneously measured by vacuum ultraviolet (VUV) absorption downstream from the plasma. Moreover, upon varying the nitrogen percentage (0%-100%), it is evidenced that the actinometry signal is proportional to the concentration measured by VUV absorption. Furthermore, it is evidenced that the oxygen dissociation rate is only 2% in pure oxygen plasmas, while it reaches 15% (433 MHz) or 30% (2450 MHz) for mixtures containing more than 20% of nitrogen. This drastic increase in [O] upon the addition of N2 is extensively discussed and, finally, attributed to a decrease in the recombination frequency of oxygen atoms on the quartz wall, in the presence of nitrogen.

  20. Imaging of spatial distributions of the millimeter wave intensity by using visible continuum radiation from a discharge in a Cs–Xe mixture. Part I: Review of the method and its fundamentals

    Energy Technology Data Exchange (ETDEWEB)

    Gitlin, M. S., E-mail: gitlin@appl.sci-nnov.ru [Russian Academy of Sciences, Institute of Applied Physics (Russian Federation)

    2017-02-15

    The first part of the review is presented which is dedicated to the time-resolved method of imaging and measuring the spatial distribution of the intensity of millimeter waves by using visible continuum (VC) emitted by the positive column (PC) of a dc discharge in a mixture of cesium vapor with xenon. The review focuses on the operating principles, fundamentals, and applications of this new technique. The design of the discharge tube and experimental setup used to create a wide homogeneous plasma slab with the help of the Cs–Xe discharge at a gas pressure of 45 Torr are described. The millimeter-wave effects on the plasma slab are studied experimentally. The mechanism of microwave-induced variations in the VC brightness and the causes of violation of the local relation between the VC brightness and the intensity of millimeter waves are discussed. Experiments on the imaging of the field patterns of horn antennas and quasi-optical beams demonstrate that this technique can be used for good-quality imaging of millimeter-wave beams in the entire millimeter-wavelength band. The method has a microsecond temporal resolution and a spatial resolution of about 2 mm. Energy sensitivities of about 10 μJ/cm{sup 2} in the Ka-band and about 200 μJ/cm{sup 2} in the D-band have been demonstrated.

  1. Wave

    DEFF Research Database (Denmark)

    Ibsen, Lars Bo

    2008-01-01

    Estimates for the amount of potential wave energy in the world range from 1-10 TW. The World Energy Council estimates that a potential 2TW of energy is available from the world’s oceans, which is the equivalent of twice the world’s electricity production. Whilst the recoverable resource is many t...

  2. International Evoked Potentials Symposium

    CERN Document Server

    1980-01-01

    The past decade has seen great progress in the measurement of evoked potentials in man; a steady increase in our understanding of their charac­ teristics, their origins and their usefulness; and a growing application in the field of clinical diagnosis. The topic is a truly multidisciplinary one. Important research contributions have been made by workers of many different backgrounds and clinical applications span the specialities. This book represents a revised and updated version of the work originally presented at the international evoked potential symposium held in Nottingham 4-6 1978. The Nottingham Symposium provided a forum for a state-of-the-art discussion amongst workers from many different disciplines and from many different countries. For each major topic in the field an expert review set the scene for discussion of current research presentations. This format is retained in the book: the chapters in Part A provide the context in which the research presented in Part B is set. The task of selecting m...

  3. Evoked acoustic emission

    DEFF Research Database (Denmark)

    Elberling, C; Parbo, J; Johnsen, N J

    1985-01-01

    Stimulated acoustic emissions were recorded in response to tonal stimuli at 60 dB p.e. SPL in a small group of normal-hearing adults. Power spectral analysis reveals that the evoked activity from each ear contains energy in preferential frequency bands and the change of stimulus frequency has onl...... reveals presence of a true emission from all ears tested. It is concluded that the cochlear echo can be recorded in normal-hearing newborns with an extremely low rate of type I errors.......Stimulated acoustic emissions were recorded in response to tonal stimuli at 60 dB p.e. SPL in a small group of normal-hearing adults. Power spectral analysis reveals that the evoked activity from each ear contains energy in preferential frequency bands and the change of stimulus frequency has only...... a minor effect on the power spectra, i.e. the maximum jumps from one spectral peak to another. Experiments with deconvolution demonstrate that the emission generating system at least at a fixed intensity can be regarded as being linear and characterized by its impulse response which is similar...

  4. Evoked potentials in multiple sclerosis.

    Science.gov (United States)

    Kraft, George H

    2013-11-01

    Before the development of magnetic resonance imaging (MRI), evoked potentials (EPs)-visual evoked potentials, somatosensory evoked potentials, and brain stem auditory evoked responses-were commonly used to determine a second site of disease in patients being evaluated for possible multiple sclerosis (MS). The identification of an area of the central nervous system showing abnormal conduction was used to supplement the abnormal signs identified on the physical examination-thus identifying the "multiple" in MS. This article is a brief overview of additional ways in which central nervous system (CNS) physiology-as measured by EPs-can still contribute value in the management of MS in the era of MRIs.

  5. STUDY ON EVOKED POTENTIALS IN TYPE 2 DIABETIC PATIENTS

    Institute of Scientific and Technical Information of China (English)

    陈薇; 陈慎仁; 陈璇; 吴静珊; 刘兴材

    2003-01-01

    The aim of this study is to explore the changes of visual evoked potentiaK VEP), brainstem auditory evoked potential (BAEP), Somatosensory e-voked potential (SEP), event-related potential(ERP) of patients with type 2 diabetes mellitus(DM).Methods VEP, BAEP, SEP, ERP were measured in 30 cases with type 2 DM (DM group) and in 30 age- and sex-matched healthy volunteers (Control group) by using Nicolet Viking Ⅳ EMG/EP instrument. The numerical values of VEP, BAEP, SEP and ERP were recorded and analyzed by SPSS.Results Abnormalities were found as follows: VEP in 20(66.7%), BAEP in 18(60%), MNSEP in 20(66.7%),PTNSEP in 22(73.3%), and ERP in 11 (36.67%) diabetic patients, including the disappearance of wave, prolonged wave latency and decreased wave amplitude. Compared with control group, the P100 latency of VEP, the latencies of wave Ⅰ and Ⅴ, amplitude of wave Ⅴ, the interpeak latencies (IPL) of each wave in BAEP, the latencies and wave amplitudes in N9 to P20 of MNSEP and in N9 to P38 of PTNSEP, as well a

  6. Bronchiolitis - discharge

    Science.gov (United States)

    RSV bronchiolitis - discharge; Respiratory syncytial virus bronchiolitis - discharge ... Your child has bronchiolitis , which causes swelling and mucus to build up in the smallest air passages of the lungs. In the hospital, ...

  7. Music evokes vivid autobiographical memories.

    Science.gov (United States)

    Belfi, Amy M; Karlan, Brett; Tranel, Daniel

    2016-08-01

    Music is strongly intertwined with memories-for example, hearing a song from the past can transport you back in time, triggering the sights, sounds, and feelings of a specific event. This association between music and vivid autobiographical memory is intuitively apparent, but the idea that music is intimately tied with memories, seemingly more so than other potent memory cues (e.g., familiar faces), has not been empirically tested. Here, we compared memories evoked by music to those evoked by famous faces, predicting that music-evoked autobiographical memories (MEAMs) would be more vivid. Participants listened to 30 songs, viewed 30 faces, and reported on memories that were evoked. Memories were transcribed and coded for vividness as in Levine, B., Svoboda, E., Hay, J. F., Winocur, G., & Moscovitch, M. [2002. Aging and autobiographical memory: Dissociating episodic from semantic retrieval. Psychology and Aging, 17, 677-689]. In support of our hypothesis, MEAMs were more vivid than autobiographical memories evoked by faces. MEAMs contained a greater proportion of internal details and a greater number of perceptual details, while face-evoked memories contained a greater number of external details. Additionally, we identified sex differences in memory vividness: for both stimulus categories, women retrieved more vivid memories than men. The results show that music not only effectively evokes autobiographical memories, but that these memories are more vivid than those evoked by famous faces.

  8. Adjective metaphors evoke negative meanings.

    Science.gov (United States)

    Sakamoto, Maki; Utsumi, Akira

    2014-01-01

    Previous metaphor studies have paid much attention to nominal metaphors and predicative metaphors, but little attention has been given to adjective metaphors. Although some studies have focused on adjective metaphors, they only examined differences in the acceptability of various types of adjective metaphors. This paper explores the cognitive effects evoked by adjective metaphors. Three psychological experiments revealed that (1) adjective metaphors, especially those modified by color adjectives, tend to evoke negative effect; (2) although the meanings of metaphors are basically affected by the meanings of their vehicles, when a vehicle has a neutral meaning, negative meanings are evoked most frequently for adjective metaphors compared to nominal and predicative metaphors; (3) negative meanings evoked by adjective metaphors are related to poeticness, and poetic metaphors evoke negative meanings more easily than less poetic metaphors. Our research sheds new light on studies of the use of metaphor, which is one of the most basic human cognitive abilities.

  9. Achieving Presence through Evoked Reality

    Directory of Open Access Journals (Sweden)

    Jayesh S. ePillai

    2013-02-01

    Full Text Available The sense of ‘Presence’ (evolving from ‘telepresence’ has always been associated with virtual reality research and is still an exceptionally mystifying constituent. Now the study of presence clearly spans over various disciplines associated with cognition. This paper attempts to put forth a concept that argues that it’s an experience of an 'Evoked Reality’ (illusion of reality that triggers an ‘Evoked Presence’ (sense of presence in our minds. A Three Pole Reality Model is proposed to explain this phenomenon. The poles range from Dream Reality to Simulated Reality with Primary (Physical Reality at the center. To demonstrate the relationship between Evoked Reality and Evoked Presence, a Reality-Presence Map is developed. We believe that this concept of Evoked Reality and the proposed model may have significant applications in the study of presence, and in exploring the possibilities of not just virtual reality but also what we call ‘reality’.

  10. 油浸变压器局放UHF电磁波传播特性仿真研究%Simulation of UHF Electromagnetic Wave Propagation for Oil-immersed Transformers with Partial Discharge

    Institute of Scientific and Technical Information of China (English)

    刘明军

    2011-01-01

    大型油浸式电力变压器结构复杂·在UHF电磁波信号传播过程中给放电量标定、局放源定位等带来难度,基于实际运行变压器结构构建精确的仿真模型,利用数值仿真技术探讨了局放UHF电磁波信号受油纸复合绝缘反射、折射及金属导体的反射、吸收表减特性,研究了检测信号强度与局放源和超高频传感嚣的位置关系,并对比分析了不同部位、不同类型放电的时域、频谱及能量累积特性,为变压器局放超高频在线监测奠定了基础.%The structure of large oil-immersed transformer is very complicated. Therefore, it is difficult for discharge calibration and location of partial discharge source in process of ultra high frequency (UHF) electromagnetic waves propagation. The exact simulation model is established with actual transformer structure. Then the effects of internal components (reflection and refraction yielded by compound insulating oiled paper, metallic conductor reflection and absorption attenuation) on the propagation characteristics of UHF electromagnetic wave are discussed through the numerical simulation technique. At the same time, the position relationship between signal intensity, discharge source and ultra high frequency sensor is studied. Finally, the time domain, spectrum and cumulative energy characteristics of different position and type discharge are comparative analysis. Thus, the study has made significantly contributions to the on-line monitoring of UHF transformers with partial discharge.

  11. Brainstem auditory evoked potential abnormalities in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Sharat Gupta

    2013-01-01

    Full Text Available Background: Diabetes mellitus represents a syndrome complex in which multiple organ systems, including the central nervous system, are affected. Aim: The study was conducted to determine the changes in the brainstem auditory evoked potentials in type 2 diabetes mellitus. Materials and Methods: A cross sectional study was conducted on 126 diabetic males, aged 35-50 years, and 106 age-matched, healthy male volunteers. Brainstem auditory evoked potentials were recorded and the results were analyzed statistically using student′s unpaired t-test. The data consisted of wave latencies I, II, III, IV, V and interpeak latencies I-III, III-V and I-V, separately for both ears. Results: The latency of wave IV was significantly delayed only in the right ear, while the latency of waves III, V and interpeak latencies III-V, I-V showed a significant delay bilaterally in diabetic males. However, no significant difference was found between diabetic and control subjects as regards to the latency of wave IV unilaterally in the left ear and the latencies of waves I, II and interpeak latency I-III bilaterally. Conclusion: Diabetes patients have an early involvement of central auditory pathway, which can be detected with fair accuracy with auditory evoked potential studies.

  12. NIPPLE DISCHARGE

    Directory of Open Access Journals (Sweden)

    T. N. Bukharova

    2008-01-01

    Full Text Available According to the data available in the literature, as high as 50% of women have benign breast tumors frequently accompanied by nip- ple discharge. Nipple discharge may be serous, bloody, purulent, and colostric. The most common causes are breast abscess, injury, drugs, prolactinoma, intraductal pappiloma, ductal ectasia, intraductal cancer (not more than 10%.

  13. Numerical Simulation Study on Wave Dissipating Performances of Air Bubbles Breakwater with Single & Double Air Discharge Pipes%单排与双排气幕防波堤消波性能数值模拟

    Institute of Scientific and Technical Information of China (English)

    张成兴; 王永学; 马加

    2011-01-01

    将气液两相流看成是变密度单流体,以连续方程、雷诺平均方程和k-ε模型为控制方程,采用VOF方法追踪两相流界面,通过UDF在连续方程中添加附加质量源项的方法,建立了气幕防波堤数学模型.通过数值计算得到的波浪透射系数同试验数据吻合较好.在此基础上讨论了不同原型入射波浪要素、不同气幕间距以及不同供气量等对单排与双排气幕防波堤消波性能的影响,进而通过分析得出相应的结论,为气幕防波堤的设计提供有意义的依据.%Assuming the two-phase fluid of water and air as a variable density fluid, a numerical model of air bubble breakwater is developed with the continuity equation, Reynolds average equation and k -e model taken as the governing equations, the VOF method for tracing the interface of the two-phase flows, and the additional source term of the air bubble model added to the continuity equation by the Macro of UDF. The transmission coefficients obtained at the different air amounts and the wave periods agree well with the experimental data. The effects of single & double air discharging pipes on the wave dissipating performance of the air bubble breakwater are analyzed with different incident wave characteristics, different distances between two air discharged pipes, the incident wave height and air amounts, then some conclusions are obtained, which are meaningful to study the wave dissipating performances of air bubble breakwaters.

  14. Stimulator with arbitrary waveform for auditory evoked potentials

    Energy Technology Data Exchange (ETDEWEB)

    Martins, H R; Romao, M; Placido, D; Provenzano, F; Tierra-Criollo, C J [Universidade Federal de Minas Gerais (UFMG), Departamento de Engenharia Eletrica (DEE), Nucleo de Estudos e Pesquisa em Engenharia Biomedica NEPEB, Av. Ant. Carlos, 6627, sala 2206, Pampulha, Belo Horizonte, MG, 31.270-901 (Brazil)

    2007-11-15

    The technological improvement helps many medical areas. The audiometric exams involving the auditory evoked potentials can make better diagnoses of auditory disorders. This paper proposes the development of a stimulator based on Digital Signal Processor. This stimulator is the first step of an auditory evoked potential system based on the ADSP-BF533 EZ KIT LITE (Analog Devices Company - USA). The stimulator can generate arbitrary waveform like Sine Waves, Modulated Amplitude, Pulses, Bursts and Pips. The waveforms are generated through a graphical interface programmed in C++ in which the user can define the parameters of the waveform. Furthermore, the user can set the exam parameters as number of stimuli, time with stimulation (Time ON) and time without stimulus (Time OFF). In future works will be implemented another parts of the system that includes the acquirement of electroencephalogram and signal processing to estimate and analyze the evoked potential.

  15. Discharge Dialogue

    DEFF Research Database (Denmark)

    Horsbøl, Anders

    2012-01-01

    less attention has been given to medical patients, who are often elderly and suffer from multiple diseases. This paper addresses the latter issue with a case study of a local initiative to improve transition from hospital to home (care) for medical patients at a Danish hospital, in which a discharge...... coordinator, employed at the hospital, is supposed to anticipate discharge and serve as mediator between the hospital and the municipal home care system. Drawing on methods from discourse and interaction analysis, the paper studies the practice of the discharge coordinator in two encounters between patients...

  16. Evoked emotions predict food choice.

    Science.gov (United States)

    Dalenberg, Jelle R; Gutjar, Swetlana; Ter Horst, Gert J; de Graaf, Kees; Renken, Remco J; Jager, Gerry

    2014-01-01

    In the current study we show that non-verbal food-evoked emotion scores significantly improve food choice prediction over merely liking scores. Previous research has shown that liking measures correlate with choice. However, liking is no strong predictor for food choice in real life environments. Therefore, the focus within recent studies shifted towards using emotion-profiling methods that successfully can discriminate between products that are equally liked. However, it is unclear how well scores from emotion-profiling methods predict actual food choice and/or consumption. To test this, we proposed to decompose emotion scores into valence and arousal scores using Principal Component Analysis (PCA) and apply Multinomial Logit Models (MLM) to estimate food choice using liking, valence, and arousal as possible predictors. For this analysis, we used an existing data set comprised of liking and food-evoked emotions scores from 123 participants, who rated 7 unlabeled breakfast drinks. Liking scores were measured using a 100-mm visual analogue scale, while food-evoked emotions were measured using 2 existing emotion-profiling methods: a verbal and a non-verbal method (EsSense Profile and PrEmo, respectively). After 7 days, participants were asked to choose 1 breakfast drink from the experiment to consume during breakfast in a simulated restaurant environment. Cross validation showed that we were able to correctly predict individualized food choice (1 out of 7 products) for over 50% of the participants. This number increased to nearly 80% when looking at the top 2 candidates. Model comparisons showed that evoked emotions better predict food choice than perceived liking alone. However, the strongest predictive strength was achieved by the combination of evoked emotions and liking. Furthermore we showed that non-verbal food-evoked emotion scores more accurately predict food choice than verbal food-evoked emotions scores.

  17. Evoked emotions predict food choice.

    Directory of Open Access Journals (Sweden)

    Jelle R Dalenberg

    Full Text Available In the current study we show that non-verbal food-evoked emotion scores significantly improve food choice prediction over merely liking scores. Previous research has shown that liking measures correlate with choice. However, liking is no strong predictor for food choice in real life environments. Therefore, the focus within recent studies shifted towards using emotion-profiling methods that successfully can discriminate between products that are equally liked. However, it is unclear how well scores from emotion-profiling methods predict actual food choice and/or consumption. To test this, we proposed to decompose emotion scores into valence and arousal scores using Principal Component Analysis (PCA and apply Multinomial Logit Models (MLM to estimate food choice using liking, valence, and arousal as possible predictors. For this analysis, we used an existing data set comprised of liking and food-evoked emotions scores from 123 participants, who rated 7 unlabeled breakfast drinks. Liking scores were measured using a 100-mm visual analogue scale, while food-evoked emotions were measured using 2 existing emotion-profiling methods: a verbal and a non-verbal method (EsSense Profile and PrEmo, respectively. After 7 days, participants were asked to choose 1 breakfast drink from the experiment to consume during breakfast in a simulated restaurant environment. Cross validation showed that we were able to correctly predict individualized food choice (1 out of 7 products for over 50% of the participants. This number increased to nearly 80% when looking at the top 2 candidates. Model comparisons showed that evoked emotions better predict food choice than perceived liking alone. However, the strongest predictive strength was achieved by the combination of evoked emotions and liking. Furthermore we showed that non-verbal food-evoked emotion scores more accurately predict food choice than verbal food-evoked emotions scores.

  18. Ileostomy - discharge

    Science.gov (United States)

    ... foods that may block your stoma are raw pineapple, nuts and seeds, celery, popcorn, corn, dried fruits ( ... ask your doctor Living with your ileostomy Low-fiber diet Small bowel resection - discharge Total colectomy or ...

  19. Gallstones - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000196.htm Gallstones - discharge To use the sharing features on this page, please enable JavaScript. You have gallstones. These are hard, pebble-like deposits that formed ...

  20. Vestibular receptors contribute to cortical auditory evoked potentials.

    Science.gov (United States)

    Todd, Neil P M; Paillard, Aurore C; Kluk, Karolina; Whittle, Elizabeth; Colebatch, James G

    2014-03-01

    Acoustic sensitivity of the vestibular apparatus is well-established, but the contribution of vestibular receptors to the late auditory evoked potentials of cortical origin is unknown. Evoked potentials from 500 Hz tone pips were recorded using 70 channel EEG at several intensities below and above the vestibular acoustic threshold, as determined by vestibular evoked myogenic potentials (VEMPs). In healthy subjects both auditory mid- and long-latency auditory evoked potentials (AEPs), consisting of Na, Pa, N1 and P2 waves, were observed in the sub-threshold conditions. However, in passing through the vestibular threshold, systematic changes were observed in the morphology of the potentials and in the intensity dependence of their amplitude and latency. These changes were absent in a patient without functioning vestibular receptors. In particular, for the healthy subjects there was a fronto-central negativity, which appeared at about 42 ms, referred to as an N42, prior to the AEP N1. Source analysis of both the N42 and N1 indicated involvement of cingulate cortex, as well as bilateral superior temporal cortex. Our findings are best explained by vestibular receptors contributing to what were hitherto considered as purely auditory evoked potentials and in addition tentatively identify a new component that appears to be primarily of vestibular origin.

  1. Interstitial lung disease - adults - discharge

    Science.gov (United States)

    Diffuse parenchymal lung disease - discharge; Alveolitis - discharge; Idiopathic pulmonary pneumonitis - discharge; IPP - discharge; Chronic interstitial lung - discharge; Chronic respiratory interstitial lung - discharge; Hypoxia - interstitial lung - discharge

  2. [Evoked potentials and inhalation anesthetics].

    Science.gov (United States)

    Thiel, A; Russ, W; Hempelmann, G

    1988-01-01

    Intraoperative monitoring of evoked potentials can be affected by various factors including volatile anaesthetics. These effects have to be considered in order to give correct interpretations of the obtained data. Visual evoked potentials (VEP) and auditory evoked potentials (AEP) will show strong alterations under general anaesthesia whereas brainstem auditory evoked potentials (BAEP) are slightly affected. The effects of nitrous oxide, halothane, enflurane, and isoflurane on somatosensory evoked potentials (SEP) after median nerve stimulation were studied in 35 healthy adult patients. pCO2 and tympanic membrane temperature were held constant. Simultaneous cervical and cortical SEP recording was performed using surface electrodes. After induction of anaesthesia SEP were recorded during normoventilation with 100% oxygen and after inhalation of 66.6% nitrous oxide. 10 patients received halothane at inspired concentrations of 0.5, 1.0, 1.5, and 2.0%. After nitrous oxide had been replaced by oxygen, halothane was reduced in steps of 0.5%. SEP were recorded at the end of each period (15 min). Equipotent doses of enflurane or isoflurane were administered to 15 and 10 patients, respectively. Nitrous oxide depressed early cortical SEP amplitude. Halothane, enflurane, and isoflurane caused dose dependent increases of latencies. Reduction of amplitude was most pronounced with isoflurane. Using high doses of enflurane in oxygen cortical SEP showed unusual high amplitudes associated with marked increases of latencies. Even under high concentrations of volatile anaesthetics cervical SEP were minimally affected. The effects of anaesthetic gases have to be considered when SEP are recorded intraoperatively.

  3. Visual evoked potentials in rubber factory workers.

    Science.gov (United States)

    Tandon, O P; Kumar, V

    1997-01-01

    Pattern reversal visual evoked potentials (pVEP) were studied in 39 male rubber factory workers in the age range of 18-55 years and 20 control subjects (aged 18-46 years) not exposed to the rubber factory environment. Results revealed that 20 (51%) rubber factory workers had abnormal latencies of wave P1 (dominant component of pVEP) as per accepted criteria of 99% tolerance limit set for the control group (i.e. any value above mean +3 SD of control was considered abnormal). The section-wise per cent distribution of abnormalities was vulcanization (83%), tubing (75%), calendering (60%), loading (38%) and mixing (14%). This study provides electrophysiological evidence that rubber factory environments affect the conduction processes in optical pathways from their origin in the retina to striate cortex. However, this study has its limitations in not identifying the specific chemical(s) causing these changes in VEP.

  4. F-wave of single firing motor units: correct or misleading criterion of motoneuron excitability in humans?

    Science.gov (United States)

    Kudina, Lydia P; Andreeva, Regina E

    2017-03-01

    Motoneuron excitability is a critical property for information processing during motor control. F-wave (a motoneuronal recurrent discharge evoked by a motor antidromic volley) is often used as a criterion of motoneuron pool excitability in normal and neuromuscular diseases. However, such using of F-wave calls in question. The present study was designed to explore excitability of single low-threshold motoneurons during their natural firing in healthy humans and to ascertain whether F-wave is a correct measure of motoneuronal excitability. Single motor units (MUs) were activated by gentle voluntary muscle contractions. MU peri-stimulus time histograms and motoneuron excitability changes within a target interspike interval were analysed during testing by motor antidromic and Ia-afferent volleys. It was found that F-waves could be occasionally recorded in some low-threshold MUs. However, during evoking F-wave, in contrast with the H-reflex, peri-stimulus time histograms revealed no statistically significant increase in MU discharge probability. Moreover, surprisingly, motoneurons appeared commonly incapable to fire a recurrent discharge within the most excitable part of a target interval. Thus, the F-wave, unlike the H-reflex, is the incorrect criterion of motoneuron excitability resulting in misleading conclusions. However, it does not exclude the validity of the F-wave as a clinical tool for other aims. It was concluded that the F-wave was first explored in low-threshold MUs during their natural firing. The findings may be useful at interpretations of changes in the motoneuron pool excitability in neuromuscular diseases.

  5. Discharge Dialogue

    DEFF Research Database (Denmark)

    Horsbøl, Anders

    2012-01-01

    For several years, efforts have been made to strengthen collaboration between health professionals with different specializations and to improve patient transition from hospital to home (care). In the Danish health care system, these efforts have concentrated on cancer and heart diseases, whereas...... less attention has been given to medical patients, who are often elderly and suffer from multiple diseases. This paper addresses the latter issue with a case study of a local initiative to improve transition from hospital to home (care) for medical patients at a Danish hospital, in which a discharge...... coordinator, employed at the hospital, is supposed to anticipate discharge and serve as mediator between the hospital and the municipal home care system. Drawing on methods from discourse and interaction analysis, the paper studies the practice of the discharge coordinator in two encounters between patients...

  6. Conduction velocity of the human spinothalamic tract as assessed by laser evoked potentials

    DEFF Research Database (Denmark)

    Cruccu, G.; Iannetti, G. D.; Agostino, R.

    2000-01-01

    To study the conduction velocity of the spinothalamic tract (STT) we delivered CO2 laser pulses, evoking pinprick sensations, to the skin overlying the vertebral spinous processes at different spinal levels from C5 to T10 and recorded evoked potentials (LEPs) in 15 healthy human subjects. These s......To study the conduction velocity of the spinothalamic tract (STT) we delivered CO2 laser pulses, evoking pinprick sensations, to the skin overlying the vertebral spinous processes at different spinal levels from C5 to T10 and recorded evoked potentials (LEPs) in 15 healthy human subjects....... These stimuli yielded large-amplitude vertex potentials consisting of a negative wave at a peak latency of about 200 ms followed by a positive wave at a peak latency of about 300 ms. The mean conduction velocity of the STT was 21 m/s, i.e. higher than the reported velocity of the corresponding primary sensory...

  7. Evoked Potentials and Human Intelligence.

    Science.gov (United States)

    Ertl, John P.; Schafer, Edward W. P.

    Evidence of a relationship between the electrical responses of the human brain and psychometric measure of intelligence is presented. These involuntary cortical responses, known as average evoked potentials are considered to be the electrical signs of information processing by the brain. The time delays of these responses from presentation of a…

  8. Evoked Emotions Predict Food Choice

    NARCIS (Netherlands)

    Dalenberg, Jelle R.; Gutjar, Swetlana; ter Horst, Gert J.; de Graaf, Kees; Renken, Remco J.; Jager, Gerry

    2014-01-01

    In the current study we show that non-verbal food-evoked emotion scores significantly improve food choice prediction over merely liking scores. Previous research has shown that liking measures correlate with choice. However, liking is no strong predictor for food choice in real life environments.

  9. Evoked Emotions Predict Food Choice

    NARCIS (Netherlands)

    Dalenberg, J.R.; Gutjar, S.; Horst, ter G.J.; Graaf, de C.; Renken, R.; Jager, G.

    2014-01-01

    In the current study we show that non-verbal food-evoked emotion scores significantly improve food choice prediction over merely liking scores. Previous research has shown that liking measures correlate with choice. However, liking is no strong predictor for food choice in real life environments. Th

  10. Double discharges in unipolar-pulsed dielectric barrier discharge xenon excimer lamps

    Science.gov (United States)

    Liu, Shuhai; Neiger, Manfred

    2003-07-01

    Excitation of dielectric barrier discharge xenon excimer lamps by unipolar short square pulses is studied in this paper. Two discharges with different polarity are excited by each voltage pulse (double discharge phenomenon). The primary discharge occurs at the top or at the rising flank of the applied unipolar square pulse, which is directly energized by the external circuit. The secondary discharge with the reversed polarity occurs at the falling flank or shortly after the falling flank end (zero external voltage) depending on the pulse width, which is energized by the energy stored by memory charges deposited by the primary discharge. Fast-speed ICCD imaging shows the primary discharge has a conic discharge appearance with a channel broadening on the anode side. This channel broadening increases with increasing the pulse top level. Only the anode-side surface discharge is observed in the primary discharge. The surface discharge on the cathode side which is present in bipolar sine voltage excitation is not observed. On the contrary, the secondary discharge has only the cathode-side surface discharge. The surface discharge on the anode side is not observed. The secondary discharge is much more diffuse than the primary discharge. Time-resolved emission measurement of double discharges show the secondary discharge emits more VUV xenon excimer radiation but less infrared (IR) xenon atomic emission than the primary discharge. It was found that the IR xenon atomic emission from the secondary discharge can be reduced by shortening the pulse width. The energy efficiency of unipolar-pulsed xenon excimer lamps (the overall energy efficiency of double discharges) is much higher than that obtained under bipolar sine wave excitation. The output VUV spectrum under unipolar pulse excitation is found to be identical to that under sine wave excitation and independent of injected electric power.

  11. Angioplasty and stent - heart - discharge

    Science.gov (United States)

    Drug-eluting stents - discharge; PCI - discharge; Percutaneous coronary intervention - discharge; Balloon angioplasty - discharge; Coronary angioplasty - discharge; Coronary artery angioplasty - discharge; Cardiac ...

  12. [Evoked potentials in intracranial operations: current status and our experiences].

    Science.gov (United States)

    Nau, H E; Hess, W; Pohlen, G; Marggraf, G; Rimpel, J

    1987-03-01

    Intraoperative neuromonitoring, especially evoked potential monitoring, has gained interest in recent years for both the anesthesiologist evaluating cerebral function and the neurosurgeon wishing to avoid neuronal lesions during intracranial operations. Before evoked potential monitoring can be introduced as a routine method of intraoperative management, experience with this method particularly in intensive care units, is imperative. We recorded evoked potentials with the Compact Four (Nicolet) and Basis 8000 (Schwarzer Picker International) computer systems. Preoperative derivations should be done with the same apparatus used intraoperatively and parameters of peri- and intraoperative derivations should not be changed. The patient's head must be fixed in a Mayfield clamp in order to avoid artefacts during trepanation. The possible artefacts due to apparatus, patient, or anesthesia are summarized in the tables. The derivations of evoked potentials should be supervised by a person who is not involved in the anesthesia or the surgical procedure; this condition may change in the future with full automatization of the recording technique and alarms. Good communication between surgeon, anesthesiologist, and neurophysiological assistant is a prerequisite. The modality is chosen in accordance with the affected neuronal system: visual-evoked potential (VEP) monitoring in the management of processes affecting the visual pathway, brain stem auditory-(BAER) and somatosensory-evoked potential (SSEP) monitoring in lesions affecting these pathways, in particular space-occupying lesions of the posterior fossa. VEP monitoring may be useful, but we observed alterations of the responses without changes in the level of anesthesia or manipulation of the visual pathways. In space-occupying processes of the cerebellopontine angle, BAER could not be developed in nearly all cases because the large underlying tumor had caused the disappearance of waves II-V. In these cases SSEP monitoring

  13. RECORDING OF VESTIBULAR EVOKED MYOGENIC POTENTIALS

    Directory of Open Access Journals (Sweden)

    A. A. Sazgar

    2006-05-01

    Full Text Available It has been shown recently that loud clicks evoke myogenic potentials in the tonically contracting sternocleidomastoid muscles. Studies have suggested that these potentials are of vestibular origin, especially of the saccule and inferior vestibular nerve. A pilot study was undertaken in our hospital to record vestibular evoked myogenic potentials (VEMP for the first time in Iran. Eighteen healthy volunteers (32 ears without history of otologic or vestibular disorders were subjected to the VEMP test. Twenty-one patients (26 ears with unilateral (6 patients and bilateral (5 patients high frequency sensorineural hearing loss with unknown etiology, acoustic neuroma (1 patient, Meniere’s disease (4 patients and unilateral low frequency sensorineural hearing loss without vestibular complaint (5 patients were also enrolled in this study. VEMP response to clicks was obtained from 84.4% of ears of healthy subjects. These subjects demonstrated short latency waves to click stimuli during tonic neck flexor activation. Mean latencies of first positive (p13 and first negative (n23 potentials in healthy subjects were 12.45 ± 1.9 ms and 20.8 ± 3.5 ms, respectively. Median latencies of these two potentials were 12.1 and 19.3 ms, respectively. We could record VEMP in 5 patients with unilateral and all patients with high and low frequency sensorineural hearing loss without vestibular complaint. In the patient with acoustic neuroma VEMP was absent on the affected side. This technique may offer a new method to evaluate otolith and sacculocollic pathways in human.

  14. Vestibular-evoked myogenic potentials.

    Science.gov (United States)

    Colebatch, J G; Rosengren, S M; Welgampola, M S

    2016-01-01

    The vestibular-evoked myogenic potential (VEMP) is a short-latency potential evoked through activation of vestibular receptors using sound or vibration. It is generated by modulated electromyographic signals either from the sternocleidomastoid muscle for the cervical VEMP (cVEMP) or the inferior oblique muscle for the ocular VEMP (oVEMP). These reflexes appear to originate from the otolith organs and thus complement existing methods of vestibular assessment, which are mainly based upon canal function. This review considers the basis, methodology, and current applications of the cVEMP and oVEMP in the assessment and diagnosis of vestibular disorders, both peripheral and central. © 2016 Elsevier B.V. All rights reserved.

  15. Achieving Presence through Evoked Reality.

    Science.gov (United States)

    Pillai, Jayesh S; Schmidt, Colin; Richir, Simon

    2013-01-01

    The sense of "Presence" (evolving from "telepresence") has always been associated with virtual reality research and is still an exceptionally mystifying constituent. Now the study of presence clearly spans over various disciplines associated with cognition. This paper attempts to put forth a concept that argues that it's an experience of an "Evoked Reality (ER)" (illusion of reality) that triggers an "Evoked Presence (EP)" (sense of presence) in our minds. A Three Pole Reality Model is proposed to explain this phenomenon. The poles range from Dream Reality to Simulated Reality with Primary (Physical) Reality at the center. To demonstrate the relationship between ER and EP, a Reality-Presence Map is developed. We believe that this concept of ER and the proposed model may have significant applications in the study of presence, and in exploring the possibilities of not just virtual reality but also what we call "reality."

  16. Time Perception and Evoked Potentials

    Science.gov (United States)

    1988-07-01

    ARI Research Note 88-69 0 MitnS.Ktohe U.0 ... Ann-r (. Time Perception and Evoked Potentials Paul FraisseDT ( Lfniversit6 Rene Descartes E LECTE...JOHNSON 00L, [N Technical Dicctojr Cmad Research accomplished under contract for the Department of the Army C. Universite Rene Descartes , Paris )r...ORGANIZATION NAME AND ADDRESS 10. PROGRAM ELEMENT. PROJECT. TASK Labrato-ire de Psychologie Experimental AREA• WORK UNIT NUMBERS Universite Rene Descartes

  17. Research on Nanosecond Pulse Corona Discharge Attenuation

    Institute of Scientific and Technical Information of China (English)

    HE Zheng-hao; XU Huai-li; BAI Jing; YU Fu-sheng; HU Feng; LI Jin

    2007-01-01

    A line-to-plate reactor was set-up in the experimental study on the application of nanosecond pulsed corona discharge plasma technology in environmental pollution control.Investigation on the attenuation and distortion of the amplitude of the pulse wave front and the discharge image as well as the waveform along the corona wire was conducted.The results show that the wave front decreases sharply during the corona discharge along the corona wire.The higher the amplitude of the applied pulse is,the more the amplitude of the wave front decreased.The wave attenuation responds in a lower corona discharge inversely.To get a higher efficiency of the line-to-plate reactor a sharp attenuation of the corona has to be considered in practical design.

  18. Development of Brainstem-Evoked Responses in Congenital Auditory Deprivation

    Directory of Open Access Journals (Sweden)

    J. Tillein

    2012-01-01

    Full Text Available To compare the development of the auditory system in hearing and completely acoustically deprived animals, naive congenitally deaf white cats (CDCs and hearing controls (HCs were investigated at different developmental stages from birth till adulthood. The CDCs had no hearing experience before the acute experiment. In both groups of animals, responses to cochlear implant stimulation were acutely assessed. Electrically evoked auditory brainstem responses (E-ABRs were recorded with monopolar stimulation at different current levels. CDCs demonstrated extensive development of E-ABRs, from first signs of responses at postnatal (p.n. day 3 through appearance of all waves of brainstem response at day 8 p.n. to mature responses around day 90 p.n.. Wave I of E-ABRs could not be distinguished from the artifact in majority of CDCs, whereas in HCs, it was clearly separated from the stimulus artifact. Waves II, III, and IV demonstrated higher thresholds in CDCs, whereas this difference was not found for wave V. Amplitudes of wave III were significantly higher in HCs, whereas wave V amplitudes were significantly higher in CDCs. No differences in latencies were observed between the animal groups. These data demonstrate significant postnatal subcortical development in absence of hearing, and also divergent effects of deafness on early waves II–IV and wave V of the E-ABR.

  19. Ulcerative colitis - discharge

    Science.gov (United States)

    Inflammatory bowel disease - ulcerative colitis - discharge; Ulcerative proctitis - discharge; Colitis - discharge ... were in the hospital because you have ulcerative colitis. This is a swelling of the inner lining ...

  20. Comparison of descending volleys evoked by transcranial and epidural motor cortex stimulation in a conscious patient with bulbar pain.

    Science.gov (United States)

    Di Lazzaro, V; Oliviero, A; Pilato, F; Saturno, E; Dileone, M; Meglio, M; Cioni, B; Papacci, F; Tonali, P A; Rothwell, J C

    2004-04-01

    To compare the pattern of activation of motor cortex produced by transcranial magnetic stimulation and epidural electrical stimulation. The spinal volleys evoked by transcranial magnetic stimulation and epidural electrical stimulation over the cerebral motor cortex were recorded from an electrode inserted into the cervical epidural space of one conscious subject who also had a cortical epidural electrode over the motor area. The volleys were termed D- and I-waves according to their latency. Magnetic stimulation was performed with a figure-of-eight coil and the induced current flowed either in a postero-anterior (PA) or in latero-medial (LM) direction. At active motor threshold intensity LM magnetic stimulation evoked a D wave whereas PA stimulation evoked an I(1) wave with later I waves being recruited at increasing stimulus intensities. Electrical epidural stimulation evoked both a D wave and I waves. However, the D wave evoked by electrical epidural stimulation had a longer latency than the LM D wave, suggesting either a more proximal site of activation of the pyramidal axon or activation of slightly faster conducting set of corticospinal fibres by LM stimulation. The I3 wave evoked by electrical epidural stimulation also had a longer latency than the PA I3-wave Epidural stimulation of the motor cortex can produce repetitive excitation of corticospinal neurones. The order of recruitment of the volleys, and the latency of the D and I3 waves may be slightly different to that seen after transcranial magnetic stimulation. Our findings suggest that there may be subtle differences in the populations of neurones activated by the two forms of stimulation.

  1. [Long-latency auditory evoked potentials in cochlear implants].

    Science.gov (United States)

    Mata, J J; Jiménez, J M; Pérez, J; Postigo, A; Roldán, B

    1999-01-01

    Cortical evoked potentials were evaluated in patients with cochlear implants. In a group of 8 adults of different ages, the lingual state before implantation and during rehabilitation were evaluated. Using cortical evoked potentials, the results of the P300 wave in response to two tones, one frequent (1,000 Hz) and the other infrequent (2,000 Hz), presented at 70 and 80 dB HL were studied. Results were analyzed and compared in relation to locutive state, rehabilitation stage, and intensity of stimulus. Absolute latencies did not differ significantly. However, latency values in relation to reaction time were significantly longer in prelingual than in postlingual patients (p test). The results confirmed the normality of central cognitive processes in patients with cochlear implants in objective assessment of P300 latency. The results suggest differences between prelingual and postlingual patients in relation to central signal processing.

  2. Visual evoked potentials in patients after methanol poisoning

    Directory of Open Access Journals (Sweden)

    Pavel Urban

    2016-06-01

    Full Text Available Objectives: We report the results of the visual evoked potentials (VEP examination in patients after severe poisoning by methanol. Material and Methods: The group of 47 patients (38 males and 9 females was assembled out of persons who survived an outbreak of poisoning by the methanol adulterated alcohol beverages, which happened in the Czech Republic in 2012–2013. The visual evoked potentials examination was performed using monocular checkerboard pattern-reversal stimulation. Two criteria of abnormality were chosen: missing evoked response, and wave P1 latency > 117 ms. Non-parametric statistical methods (median, range, and the median test were used to analyze factors influencing the VEP abnormality. Results: The visual evoked potential was abnormal in 20 patients (43%, 5 of them had normal visual acuity on the Snellen chart. The VEP abnormality did not correlate significantly with initial serum concentrations of methanol, formic acid or lactate; however, it showed statistically significant inverse relation to the initial serum pH: the subgroup with the abnormal VEP had significantly lower median pH in comparison with the subgroup with the normal VEP (7.16 vs. 7.34, p = 0.04. The abnormality was not related to chronic alcohol abuse. Conclusions: The visual evoked potentials examination appeared sensitive enough to detected even subclinical impairment of the optic system. Metabolic acidosis is likely to be the key factor related to the development of visual damage induced by methanol. The examination performed with a delay of 1–9 months after the poisoning documented the situation relatively early after the event. It is considered as a baseline for the planned long-term follow-up of the patients, which will make it possible to assess the dynamics of the observed changes, their reversibility, and the occurrence of potential late sequelae.

  3. Pediatric heart surgery - discharge

    Science.gov (United States)

    ... discharge; Heart valve surgery - children - discharge; Heart surgery - pediatric - discharge; Heart transplant - pediatric - discharge ... Geme JW, Schor NF, eds. Nelson Textbook of Pediatrics . 20th ed. Philadelphia, PA: Elsevier; 2016:chap 434. ...

  4. Lung surgery - discharge

    Science.gov (United States)

    ... Lung biopsy - discharge; Thoracoscopy - discharge; Video-assisted thoracoscopic surgery - discharge; VATS - discharge ... milk) for 2 weeks after video-assisted thoracoscopic surgery and 6 to 8 weeks after open surgery. ...

  5. Refractive corneal surgery - discharge

    Science.gov (United States)

    Nearsightedness surgery - discharge; Refractive surgery - discharge; LASIK - discharge; PRK - discharge ... You had refractive corneal surgery to help improve your vision. This surgery uses a laser to reshape your cornea. It corrects mild-to-moderate nearsightedness, ...

  6. Speech-evoked auditory brainstem responses in children with hearing loss.

    Science.gov (United States)

    Koravand, Amineh; Al Osman, Rida; Rivest, Véronique; Poulin, Catherine

    2017-08-01

    The main objective of the present study was to investigate subcortical auditory processing in children with sensorineural hearing loss. Auditory Brainstem Responses (ABRs) were recorded using click and speech/da/stimuli. Twenty-five children, aged 6-14 years old, participated in the study: 13 with normal hearing acuity and 12 with sensorineural hearing loss. No significant differences were observed for the click-evoked ABRs between normal hearing and hearing-impaired groups. For the speech-evoked ABRs, no significant differences were found for the latencies of the following responses between the two groups: onset (V and A), transition (C), one of the steady-state wave (F), and offset (O). However, the latency of the steady-state waves (D and E) was significantly longer for the hearing-impaired compared to the normal hearing group. Furthermore, the amplitude of the offset wave O and of the envelope frequency response (EFR) of the speech-evoked ABRs was significantly larger for the hearing-impaired compared to the normal hearing group. Results obtained from the speech-evoked ABRs suggest that children with a mild to moderately-severe sensorineural hearing loss have a specific pattern of subcortical auditory processing. Our results show differences for the speech-evoked ABRs in normal hearing children compared to hearing-impaired children. These results add to the body of the literature on how children with hearing loss process speech at the brainstem level. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Visual evoked potentials, reaction times and eye dominance in cricketers.

    Science.gov (United States)

    Thomas, N G; Harden, L M; Rogers, G G

    2005-09-01

    Few studies have examined the physiology of cricket, including the difference in ability between batsmen to make controlled contact with a ball bowled at high speed. We therefore measured visual evoked potentials and choice reaction times with dominant eyes, non-dominant eyes, and both eyes together, in 15 elite batsmen and 10 elite bowlers (aged 20.9 SD 1.9 years) and 9 control subjects (aged 20.2 SD 1.5 years). The latency and amplitude of waves N70, P100 and N145 were determined for each visual evoked potential (VEP). In addition interpeak latencies and peak to peak amplitudes were measured. The subjects also completed a choice reaction test to a visual stimulus. We found that cricketers were not more likely to have crossed dominance (dominant eye contralateral to dominant hand) than controls. Cricketers had a faster latency for VEP wave N70 than controls (p=0.03). However reaction time was not different between cricketers and the control group. Across all subjects, in comparison to monocular testing, binocular testing led to a faster choice reaction time (p=0.02) and larger amplitudes of VEP wave N70 (p=0.01). Visual processing during the first 100(-1)50 ms of the balls flight together with binocular vision facilitates retinal activation in talented cricketers.

  8. Characterisation of pulsed discharge in water

    Science.gov (United States)

    Kocik, Marek; Dors, Miroslaw; Podlinski, Janusz; Mizeraczyk, Jerzy; Kanazawa, Seiji; Ichiki, Ryuta; Sato, Takehiko

    2013-10-01

    In this paper, Schlieren photography technique has been applied for the visualization of the pressure field of a single-shot underwater pulsed discharge. A needle-to-plane electrode configuration submerged in distilled water was used. The detailed time- and space-resolved images of both streamers and pressure waves were captured. As a result, several phenomena, such as the phase change prior to the initiation of the discharge, primary and secondary streamers propagation, shock wave generation, and the bubble formation, were observed. From these observations, a scenario of multiple events from prebreakdown to post-discharge was proposed. The gas bubbles generated in discharge were used to visualize the electrohydrodynamic flow induced by the discharge. This work was presented on the occasion of the 13th International Symposium on High Pressure Low Temperature Plasma Chemistry (Hakone XIII).

  9. Brain stem auditory evoked responses in human infants and adults

    Science.gov (United States)

    Hecox, K.; Galambos, R.

    1974-01-01

    Brain stem evoked potentials were recorded by conventional scalp electrodes in infants (3 weeks to 3 years of age) and adults. The latency of one of the major response components (wave V) is shown to be a function both of click intensity and the age of the subject; this latency at a given signal strength shortens postnatally to reach the adult value (about 6 msec) by 12 to 18 months of age. The demonstrated reliability and limited variability of these brain stem electrophysiological responses provide the basis for an optimistic estimate of their usefulness as an objective method for assessing hearing in infants and adults.

  10. Vestibular-evoked myogenic potentials in miniature pigs

    Institute of Scientific and Technical Information of China (English)

    Xi Shi; Yan Zhang; Ya Li; Shiwei Qiu; Shili Zhang; Yaohan Li; Na Yuan; Yuehua Qiao; Shiming Yang

    2016-01-01

    Objective:To report detection of vestibular-evoked myogenic potentials (VEMPs) in the miniature pig. Methods:Potentials evoked by 1000 Hz tone bursts were recorded from neck extensor muscles and the masseter muscles in normal adult Bama miniature pigs anesthetized with 3%pentobarbital sodium and Carbachol II. Results:The latency of the first positive wave P from neck extensor muscles was 7.65 ± 0.64 ms, with an amplitude of 1.66 ± 0.34 uv and a rate of successful induction of 75%at 80 dB SPL. The latency of potentials evoked from the masseter muscles was 7.60 ± 0.78 ms, with an amplitude of 1.31 ± 0.28 uv and a rate successful induction of 66%at 80 dB SPL. Conclusion:The latencies and thresholds of VEMPs recorded from the neck extensor muscle and the masseter muscle appear to be comparable in normal adult Bama miniature pigs, although the amplitude recorded from the neck extensor muscle seems to be higher than that from the masseter muscle. However, because of their usually relatively superficial and easily accessible location, as well as their large volume and strong contractions, masseter muscles may be better target muscles for recording myogenic potentials.

  11. Brainstem auditory evoked potentials in children with lead exposure

    Directory of Open Access Journals (Sweden)

    Katia de Freitas Alvarenga

    2015-02-01

    Full Text Available Introduction: Earlier studies have demonstrated an auditory effect of lead exposure in children, but information on the effects of low chronic exposures needs to be further elucidated. Objective: To investigate the effect of low chronic exposures of the auditory system in children with a history of low blood lead levels, using an auditory electrophysiological test. Methods: Contemporary cross-sectional cohort. Study participants underwent tympanometry, pure tone and speech audiometry, transient evoked otoacoustic emissions, and brainstem auditory evoked potentials, with blood lead monitoring over a period of 35.5 months. The study included 130 children, with ages ranging from 18 months to 14 years, 5 months (mean age 6 years, 8 months ± 3 years, 2 months. Results: The mean time-integrated cumulative blood lead index was 12 µg/dL (SD ± 5.7, range:2.433. All participants had hearing thresholds equal to or below 20 dBHL and normal amplitudes of transient evoked otoacoustic emissions. No association was found between the absolute latencies of waves I, III, and V, the interpeak latencies I-III, III-V, and I-V, and the cumulative lead values. Conclusion: No evidence of toxic effects from chronic low lead exposures was observed on the auditory function of children living in a lead contaminated area.

  12. Effects of the body temperature on the synthetic wave of electrocochleogram and brain stem auditory evoked potentials in guinea pigs%体温对豚鼠耳蜗电图-脑干听觉诱发电位综合波的影响

    Institute of Scientific and Technical Information of China (English)

    何斯纯; 马宁; 周卓妍; 周丽丽

    2005-01-01

    背景:脑干听觉诱发电位(brainstem auditory evoked potentials,BAEP)和耳蜗电图(electrocochleogram,ECochG)两者综合波的新记录方法具有特殊临床意义,探讨体温升高和体温降低对其的影响对进一步明确ECochG-BAEP综合波的生理特性和指导其临床应用有重要意义.目的:观察体温升高和体温降低对ECochG-BAEP综合波的影响效应.设计:随机区组设计.单位:暨南大学医学院生理教研室.对象:实验于2002-07/09在暨南大学医学院生理学教研室进行,选择成年豚鼠(300~350 g),雌雄不拘,由第一军医大学动物实验中心提供,随机分为体温降低组(20只)和体温升高组(20只).干预:体温降低组,体表物理降温法逐步降低豚鼠体温;体温升高组,体表物理升温法逐步升高豚鼠体温.主要观察指标:ECochG-BAEP综合波的波形、波峰潜伏期(PL)、波峰间潜伏期(IPL)和波幅随体温发生的变化.结果:随体温降低(36~25℃)和体温升高(36~42℃),ECochG-BAEP综合波波形始终兼具BAEP和ECochG两者的特点,有十分明显突出的1波;各波PL和IPL随体温降低而逐步延长,但随体温升高而逐渐缩短;1,2,3波波幅在体温降低至30~29℃时开始出现显著降低,1,2波波幅也在体温升高至40℃后开始出现显著降低.结论:体温降低和体温升高对ECochG-BAEP SW的PL,IPL和波幅均有显著影响,但其波形始终兼具BAEP和ECochG两者的特点.%BACKGROUND: A new method for recording the synthetic wave of electrocochleogram-brain stem auditory evoked potentials(ECochG-BAEP SW)has special clinical significance. The study of effects of hypothermia and hyperthermia on the synthetic wave is significant to define its physiological properties and to guide its clinical application.OBJECTIVE: To observe the effects of hypothermia and hyperthermia on ECochG-BAEP SW.DESIGN: A randomized block design.SETTING: Department of Physiology, Medical College of Jinan University

  13. Comparison of the pattern reversal visual evoked potential mediated by separate cone systems

    DEFF Research Database (Denmark)

    Johnsen, B; Frederiksen, J.L.; Larsson, H.B.

    1995-01-01

    With the purpose of recording responses mediated by the 3 cone systems visual evoked potentials (VEPs) were elicited by the reversal of monochromatic checkerboards superimposed upon strong monochromatic backgrounds (yellow, purple and blue-green). The sensitivity to light of various wave lengths...

  14. Research on Partial Discharge Detection and Localization of Dry-Type Transformer Based on UHF and Ultrasonic Wave%基于超高频和超声波的干式变压器局部放电检测与定位的研究

    Institute of Scientific and Technical Information of China (English)

    王永强; 张涛; 王慧君

    2013-01-01

    The demand for the safety and effective of the dry-type transformer is high in the process of operation, therefore the partial discharge detection of dry-type transformer is particularly important. This paper mainly analyzes the principle and test methods of UHF and ultrasonic wave based partial discharge detection methods for dry-type transformer. A partial discharge detection system is built based on the combination of UHF and ultrasonic wave methods, which can locate the partial discharge source. This system provides reference for partial discharge detection.%对于干式变压器在运行过程中的安全有效性要求越来越高,因此对其进行局部放电检测尤为重要。本文主要分析了检测干式变压器局部放电的超高频方法与超声波方法的原理及检测方法,并设计了一套超高频与超声波相联合的局部放电检测系统,通过该系统,对局部放电源进行定位,对干式变压器的局部放电检测提供了参考。

  15. Peak latency prolongation of Ⅴ wave in brainstem auditory evoked potential during intraoperative monitoring of acoustic neuroma surgery%脑干听觉诱发电位的Ⅴ波PL延长在听神经瘤手术监护中的应用价值

    Institute of Scientific and Technical Information of China (English)

    包国庆; 朱沂; 李建新; 杨小朋

    2012-01-01

    目的 探讨BAEP的Ⅴ波PL延长在听神经瘤手术中的应用价值. 方法 回顾性分析55例听神经瘤手术患者行BAEP术前检查、术中监护及术后疗效评估,分析Ⅴ波PL延长不同指标的监测结果. 结果 以Ⅴ波PL延长>0.6 ms为标准,脑干或听神经损伤的灵敏度100%,特异度95.3%,误诊率4.7%,漏诊率0%,符合率96.4%.以Ⅴ波PL延长>1.0 ms为标准,灵敏度58.3%,特异度97.7%,误诊率2.3%,漏诊率41.7%,符合率89.1%. 结论 BAEP监护听神经瘤手术中,V波PL延长>0.6 ms有较高的敏感度和特异度,作为术中监护报警指标更合适.%Objective To explore the applied value of peak latency (PL) prolongation of Ⅴ wave in brainstem auditory evoked potential (BAEP) during intraoperative monitoring of acoustic neuroma surgery. Methods The preoperative BAEP examination data,intraoperative monitoring and postoperative evaluation data in 55 patients with acoustic neuroma were retrospectively analyzed; the monitoring results under the circumstance that different degrees of prolongation of PL of Ⅴ wave were chosen were analyzed. Results The PL prolongation of Ⅴ wave >0.6 ms was used as the baseline,the sensitivity of diagnosing the brainstem or acoustic nerve injury was 100%,the specificity was 95.3%,the misdiagnosis rate was 4.7%,the missed diagnosis rate was 0% and the accordance rate was 96.4%.The PL prolongation of Ⅴ wave >1.0 ms was used as the baseline,the sensitivity of diagnosing the brainstem or acoustic nerve injury was 58.3%,the specificity was 97.7%,the misdiagnosis rate was 2.3%,the missed diagnosis rate was 41.7% and the accordance rate was 89.1%. Conclusion It is more suitable that using thePL prolongation of Ⅴ wave >0.6 ms as the baseline,enjoying high sensitivity and specificity,during the intraoperative monitoring of acoustic neuroma.

  16. Heating dominated inception of pulsed discharges

    Science.gov (United States)

    Agnihotri, Ashutosh; Hundsdorfer, Willem; Ebert, Ute

    2016-09-01

    We simulate the inception of pulsed discharges with heating as the driving agent that leads to spark formation. To understand the phenomenon, we developed a 2D-cylindrically symmetric model that couples the electric discharge dynamics with the background gas dynamics. To capture the ion dynamics well, we reduced the classical drift-diffusion-reaction model of electric discharges to the timescale of ion motion. Additionally, we include secondary emission of electrons from the cathode. We employed the model to study electrical breakdown in air at STP conditions between planar electrodes under the application of pulsed voltages. Our model captures space-charge effects, thermal shocks and induced pressure waves. We observe a cycle of discharge pulses heating the gas and the thermal expansion helping the discharge. This cycle might either lead to spark formation or to discharge decay.

  17. Astrocytes generate Na+-mediated metabolic waves.

    Science.gov (United States)

    Bernardinelli, Yann; Magistretti, Pierre J; Chatton, Jean-Yves

    2004-10-12

    Glutamate-evoked Na+ increase in astrocytes has been identified as a signal coupling synaptic activity to glucose consumption. Astrocytes participate in multicellular signaling by transmitting intercellular Ca2+ waves. Here we show that intercellular Na+ waves are also evoked by activation of single cultured cortical mouse astrocytes in parallel with Ca2+ waves; however, there are spatial and temporal differences. Indeed, maneuvers that inhibit Ca2+ waves also inhibit Na+ waves; however, inhibition of the Na+/glutamate cotransporters or enzymatic degradation of extracellular glutamate selectively inhibit the Na+ wave. Thus, glutamate released by a Ca2+ wave-dependent mechanism is taken up by the Na+/glutamate cotransporters, resulting in a regenerative propagation of cytosolic Na+ increases. The Na+ wave gives rise to a spatially correlated increase in glucose uptake, which is prevented by glutamate transporter inhibition. Therefore, astrocytes appear to function as a network for concerted neurometabolic coupling through the generation of intercellular Na+ and metabolic waves.

  18. Evoked potentials in Guillain-Barré syndrome.

    Science.gov (United States)

    Ropper, A H; Chiappa, K H

    1986-04-01

    We studied evoked potentials (EPs) in 27 patients with typical acute Guillain-Barré syndrome and 3 with Fisher's syndrome. Three of 21 had BAEP abnormalities: 1 with bilateral I-III, 1 with unilateral I-III, and another with unilateral III-V interwave latency prolongations. Three with Fisher's syndrome had normal BAEPs (one had a poorly formed wave V unilaterally with one click polarity only). Ten of 21 median nerve EPs and 9 of 12 peroneal or tibial nerve somatosensory EPs were abnormal. Seven patients with normal somatosensory EPs had abnormal F waves from the same nerve; none had normal late responses and abnormal somatosensory EPs. These observations differ from previous reports on the frequency and interpretation of EP abnormalities in Guillain-Barré syndrome.

  19. Auditory evoked field measurement using magneto-impedance sensors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, K., E-mail: o-kabou@echo.nuee.nagoya-u.ac.jp; Tajima, S.; Song, D.; Uchiyama, T. [Graduate School of Engineering, Nagoya University, Nagoya (Japan); Hamada, N.; Cai, C. [Aichi Steel Corporation, Tokai (Japan)

    2015-05-07

    The magnetic field of the human brain is extremely weak, and it is mostly measured and monitored in the magnetoencephalography method using superconducting quantum interference devices. In this study, in order to measure the weak magnetic field of the brain, we constructed a Magneto-Impedance sensor (MI sensor) system that can cancel out the background noise without any magnetic shield. Based on our previous studies of brain wave measurements, we used two MI sensors in this system for monitoring both cerebral hemispheres. In this study, we recorded and compared the auditory evoked field signals of the subject, including the N100 (or N1) and the P300 (or P3) brain waves. The results suggest that the MI sensor can be applied to brain activity measurement.

  20. Hearing outcomes after loss of brainstem auditory evoked potentials during microvascular decompression.

    Science.gov (United States)

    Thirumala, Parthasarathy D; Krishnaiah, Balaji; Habeych, Miguel E; Balzer, Jeffrey R; Crammond, Donald J

    2015-04-01

    The primary aim of this paper is to study the pre-operative characteristics, intra-operative changes and post-operative hearing outcomes in patients after complete loss of wave V of the brainstem auditory evoked potential. We retrospectively analyzed the brainstem auditory evoked potential data of 94 patients who underwent microvascular decompression for hemifacial spasm at our institute. Patients were divided into two groups - those with and those without loss of wave V. The differences between the two groups and outcomes were assessed using t-test and chi-squared tests. In our study 23 (24%) patients out of 94 had a complete loss of wave V, with 11 (48%) patients experiencing transient loss and 12 (52%) patients experiencing permanent loss. The incidence of hearing loss in patients with no loss of wave V was 5.7% and 26% in patients who did experience wave V loss. The incidence of hearing change in patients with no loss of wave V was 12.6% and 30.43% in patients who did experience wave V loss. Loss of wave V during the procedure or at the end of procedure significantly increases the odds of hearing loss. Hearing change is a significant under-reported clinical condition after microvascular decompression in patients who have loss of wave V.

  1. Concussion - adults - discharge

    Science.gov (United States)

    Brain injury - concussion - discharge; Traumatic brain injury - concussion - discharge; Closed head injury - concussion - discharge ... Getting better from a concussion takes days to weeks or even months. ... have trouble concentrating, or be unable to remember things. ...

  2. Tennis elbow surgery - discharge

    Science.gov (United States)

    ... epicondylitis surgery - discharge; Lateral tendinosis surgery - discharge; Lateral tennis elbow surgery - discharge ... long as you are told. This helps ensure tennis elbow will not return. You may be prescribed a ...

  3. Asthma - child - discharge

    Science.gov (United States)

    Pediatric asthma - discharge; Wheezing - discharge; Reactive airway disease - discharge ... Your child has asthma , which causes the airways of the lungs to swell and narrow. In the hospital, the doctors and nurses helped ...

  4. Eye muscle repair - discharge

    Science.gov (United States)

    ... Lazy eye repair - discharge; Strabismus repair - discharge; Extraocular muscle surgery - discharge ... You or your child had eye muscle repair surgery to correct eye muscle ... term for crossed eyes is strabismus. Children most often ...

  5. Neck dissection - discharge

    Science.gov (United States)

    Radical neck dissection - discharge; Modified radical neck dissection - discharge; Selective neck dissection - discharge ... 659-665. Robbins KT, Samant S, Ronen O. Neck dissection. In: Flint PW, Haughey BH, Lund V, et ...

  6. ACL reconstruction - discharge

    Science.gov (United States)

    Anterior cruciate ligament reconstruction - discharge; ACL reconstruction - discharge ... had surgery to reconstruct your anterior cruciate ligament (ACL). The surgeon drilled holes in the bones of ...

  7. EVOKED CAVERNOUS ACTIVITY: NEUROANATOMIC IMPLICATIONS

    Science.gov (United States)

    Yilmaz, Ugur; Vicars, Brenda; Yang, Claire C.

    2013-01-01

    We investigated the autonomic innervation of the penis by using evoked cavernous activity (ECA). We recruited 7 males with thoracic spinal cord injury (SCI) and sexual dysfunction and 6 males who were scheduled to have pelvic surgery (PS), specifically non-nerve-sparing radical cystoprostatectomy. In the PS subjects, ECA was performed both pre- and postoperatively. The left median nerve was electrically stimulated and ECA was recorded with two concentric electromyography needles placed into the right and left cavernous bodies. We simultaneously recorded hand and foot sympathetic skin responses (SSRs) as controls. In the SCI group, all but one subject had reproducible hand SSRs. None of these subjects had ECA or foot SSRs. All the PS subjects had reproducible ECA and SSRs, both preoperatively and postoperatively. There was no difference in the latency and amplitude measurements of ECA and SSRs in the postoperative compared to the preoperative period (p>0.05). In conclusion, ECA is absent in men with SCI above the sympathetic outflow to the genitalia. In men following radical pelvic surgery, ECA is preserved, indicating the preservation of sympathetic fibers. PMID:19609298

  8. Ocular Vestibular Evoked Myogenic Potentials

    Directory of Open Access Journals (Sweden)

    Felipe, Lilian

    2014-01-01

    Full Text Available Introduction Diagnostic testing of the vestibular system is an essential component of treating patients with balance dysfunction. Until recently, testing methods primarily evaluated the integrity of the horizontal semicircular canal, which is only a portion of the vestibular system. Recent advances in technology have afforded clinicians the ability to assess otolith function through vestibular evoked myogenic potential (VEMP testing. VEMP testing from the inferior extraocular muscles of the eye has been the subject of interest of recent research. Objective To summarize recent developments in ocular VEMP testing. Results Recent studies suggest that the ocular VEMP is produced by otolith afferents in the superior division of the vestibular nerve. The ocular VEMP is a short latency potential, composed of extraocular myogenic responses activated by sound stimulation and registered by surface electromyography via ipsilateral otolithic and contralateral extraocular muscle activation. The inferior oblique muscle is the most superficial of the six extraocular muscles responsible for eye movement. Therefore, measurement of ocular VEMPs can be performed easily by using surface electrodes on the skin below the eyes contralateral to the stimulated side. Conclusion This new variation of the VEMP procedure may supplement conventional testing in difficult to test populations. It may also be possible to use this technique to evaluate previously inaccessible information on the vestibular system.

  9. [Intraoperative Visual Evoked Potential Monitoring].

    Science.gov (United States)

    Hayashi, Hironobu; Kawaguchi, Masahiko

    2015-05-01

    Visual evoked potential (VEP) is recorded from the back of the head, which is elicited by retinal stimulation transmitted through optic nerve, optic chiasm, optic tract lateral geniculate body, optic radiation and finally cortical visual area. VEP monitoring did not prevail since 1990s because marked intra-individual difference and instability of VEP recording limited the clinical usefulness under inhalation anesthetic management and techniques of VEP monitoring at the time. However, recent advances in techniques including a new light-stimulating device consisting of high-luminosity LEDs and induction of electroretinography to ascertain the arrival of the stimulus at the retina provided better conditions for stable VEP recording under general anesthesia. In addition, the introduction of total intravenous anesthesia using propofol is important for the successful VEP recordings because inhaled anesthetics have suppressive effect on VEP waveform. Intraoperative VEP has been considered to monitor the functional integrity of visual function during neurosurgical procedures, in which the optic pathway is at a risk of injury. Intraoperative VEP monitoring may allow us to detect reversible damage to the visual pathway intraoperatively and enable us to prevent permanent impairment.

  10. Numerical Analysis of Partial Discharge Electromagnetic Wave Propagation Characteristics in XLPE Cables and Joints%XLPE电缆及其中间接头中局部放电电磁波传播特性的数值分析

    Institute of Scientific and Technical Information of China (English)

    黄志伟; 杨宇琦; 薛荣; 李洪杰

    2014-01-01

    Partial discharge (PD) detection and location is of great significance for the power cable insulation condition monitoring, so an adequate cable model is needed to build to analyze the PD electromagnetic pulse propagation characteristics. Considering the complex structure of the cable and high accurate equivalent circuit model is hard to obtain, we applied numerical electromagnetic method. The propagation characteristics of PD electromagnetic wave of cables and joints in time domain were analyzed through building good cable model, and the propagation characteristics were simulated. The electric field produced by the PD source propagating along different directions was calculated, and the calculated PD waveforms in the cable are compared with those in the cable joint model. The results show that the propagation characteristics of PD electromagnetic wave in the cable and joint have big difference. Therefore, the PD detection and location for cables need to consider the effects of cable joints.%局部放电(PD)检测和定位对电力电缆绝缘状态监测具有十分重要的意义,有必要建立一个精确的电缆模型对局部放电电磁脉冲的传播特性进行分析。考虑到电缆结构的复杂性,难以得到高精度的等效电路模型,因此采用数值电磁方法,通过构建良好的电缆模型,在时域中分析电缆及其中间接头的局部放电电磁波的传播特性,并对其传播特性进行仿真,计算局部放电源沿不同方向传播产生的电场,将计算得到的电缆中的PD信号波形与接头模型中的信号波形进行对比。结果表明,局部放电产生的电磁波在电缆和电缆中间接头中的传播规律存在很大差异,因此,在电缆局部放电检测与定位时要考虑电缆中间接头的影响。

  11. 阻尼振荡波电压和工频电压下XLPE电缆局部放电特性的对比研究%Comparative Study on Partial Discharge Characteristics of XLPE Cable under Damped Oscillating Wave Voltage and AC Voltage

    Institute of Scientific and Technical Information of China (English)

    薛荣; 张龙; 黄志伟; 张伟; 李洪杰

    2015-01-01

    The partial discharge characteristics of four defects in heat-shrinkable cable accessories, which were termination without stress tube, incorrect use of insulation tape as semi-conductive adhesive tape in the middle joint, void and metal particles on the surface of XLPE insulation, were studied by AC volt-age method and damped oscillating wave voltage method. The partial discharge inception voltage and pat-terns under damped oscillating wave voltage and AC voltage were compared. The results show that the two methods are consistent in the study of partial discharge characteristics, and there are obvious differ-ences in the partial discharge statistical characteristics of various defects.%采用工频电压法和阻尼振荡波电压法研究热缩式电缆附件在4种缺陷情况下的局部放电特性,对比分析两种电压情况下的局部放电起始电压和局放模式。结果表明:两种方法在局部放电特性研究中具有一致性,各种缺陷的局部放电统计特征具有较为明显的差异。

  12. Evoked potentials in neuroinfections in children

    Directory of Open Access Journals (Sweden)

    V. N. Komantsev

    2013-01-01

    Full Text Available We present the results of the neurophysiological study in which 95 children with viral encephalitis and 30 children with meningitis (age from 2 up to 17 years undergo evoked potentials investigation. Some specific features of evoked potentials in neuroinfections have been shown to correlate with the course of disease and the age of the patients. We give a description of a logistic model of predicting outcomes in such patients by complex diagnostic method. We have found that evoked potentials may be successfully implemented in correcting the therapeutic strategies. Study of evoked potentials in neuroinfections in children can define the severity and extent of lesions and help to identify subclinical dysfunction and monitor the recovery processes under the therapy.

  13. Visual Evoked Potentials in Rett Syndrome

    Directory of Open Access Journals (Sweden)

    J. Gordon Millichap

    2015-11-01

    Full Text Available Investigators from the Boston Children's Hospital recorded pattern-reversal visual evoked potentials (VEPs in Mecp2 heterozygous female mice and in 34 girls with Rett syndrome (RTT.

  14. An Analysis and Administration System for Cable Partial Discharge Data Based on Oscillatory Wave Voltage Method%基于振荡波电压法的电缆局部放电数据分析与管理系统

    Institute of Scientific and Technical Information of China (English)

    熊俊; 陆国俊

    2013-01-01

    基于振荡波电压法,考虑了局部放电信号的入射波形与反射波形时间限制、相似性、时频衰减性等因素,开发了一个电缆局部放电数据分析与管理系统。该系统与现场采集的原始数据兼容,具有定位算法精度高、数据分散性较小的特点,且系统能够实现电缆局部放电信息台账管理、状态评估与风险管理及打印报表等。%Based on the oscillatory wave voltage method, and taking the factors into account such as the time limit, similarity, time-frequency attenuation of incident wave and reflected wave in partial discharge signal, this paper develops an analysis and administration system for cable partial discharge data. The system is compatible with the original data collected from spot, and has the characteristics of high positioning accuracy and low data dispersion, and is able to realize the functions such as the account management of partial discharge informationt, condition assessment, risk management and report printing.

  15. Do ambient urban odors evoke basic emotions?

    OpenAIRE

    Sandra Theresia Weber-Glass; Elisabeth eLingg; Eva eHeuberger

    2014-01-01

    Fragrances, such as plant odors, have been shown to evoke autonomic response patterns associated with Ekman’s (Ekman et al., 1983) basic emotions happiness, surprise, anger, fear, sadness and disgust. Inducing positive emotions by odors in highly frequented public spaces could serve to improve the quality of life in urban environments. Thus, the present study evaluated the potency of ambient odors connoted with an urban environment to evoke basic emotions on an autonomic and cognitive respons...

  16. Visual evoked potentials in optic nerve injury--does it merit to be mentioned?

    Directory of Open Access Journals (Sweden)

    Mahapatra A

    1991-01-01

    Full Text Available The value of Visual Evoked Potentials (VEP in the management of indirect optic nerve injury was prospectively studied in 78 patients. The initial VEPs were normal in 10, abnormal in 29 and absent in 39 patients. All 10 patients with normal VEP showed visual recovery. Amongst 29 patients with abnormal VEP, 26 (86.6% showed improvement. In 39 patients initial VEPs showed no wave, however, subsequent VEP recordings demonstrated wave formation. Thus in 31 patients repeated VEP recordings failed to demonstrate wave formation, and none of them improved. This study, thus brings out the high predictive value of both positive and negative VEPs.

  17. Vestibular evoked myogenic potential findings in multiple sclerosis.

    Science.gov (United States)

    Escorihuela García, Vicente; Llópez Carratalá, Ignacio; Orts Alborch, Miguel; Marco Algarra, Jaime

    2013-01-01

    Multiple sclerosis is an inflammatory disease involving the occurrence of demyelinating, chronic neurodegenerative lesions in the central nervous system. We studied vestibular evoked myogenic potentials (VEMPs) in this pathology, to allow us to evaluate the saccule, inferior vestibular nerve and vestibular-spinal pathway non-invasively. There were 23 patients diagnosed with multiple sclerosis who underwent VEMP recordings, comparing our results with a control group consisting of 35 healthy subjects. We registered p13 and n23 wave latencies, interaural amplitude difference and asymmetry ratio between both ears. Subjects also underwent an otoscopy and audiometric examination. The prolongation of p13 and n23 wave latencies was the most notable characteristic, with a mean p13 wave latency of 19.53 milliseconds and a mean latency of 30.06 milliseconds for n23. In contrast, the asymmetry index showed no significant differences with our control group. In case of multiple sclerosis, the prolongation of the p13 and n23 VEMP wave latencies is a feature that has been attributed to slowing of conduction by demyelination of the vestibular-spinal pathway. In this regard, alteration of the response or lack thereof in these potentials has a locator value of injury to the lower brainstem. Copyright © 2013 Elsevier España, S.L. All rights reserved.

  18. Evoked EMG versus Muscle Torque during Fatiguing Functional Electrical Stimulation-Evoked Muscle Contractions and Short-Term Recovery in Individuals with Spinal Cord Injury

    Directory of Open Access Journals (Sweden)

    Eduardo H. Estigoni

    2014-12-01

    Full Text Available This study investigated whether the relationship between muscle torque and m-waves remained constant after short recovery periods, between repeated intervals of isometric muscle contractions induced by functional electrical stimulation (FES. Eight subjects with spinal cord injury (SCI were recruited for the study. All subjects had their quadriceps muscles group stimulated during three sessions of isometric contractions separated by 5 min of recovery. The evoked-electromyographic (eEMG signals, as well as the produced torque, were synchronously acquired during the contractions and during short FES bursts applied during the recovery intervals. All analysed m-wave variables changed progressively throughout the three contractions, even though the same muscle torque was generated. The peak to peak amplitude (PtpA, and the m-wave area (Area were significantly increased, while the time between the stimulus artefact and the positive peak (PosT were substantially reduced when the muscles became fatigued. In addition, all m-wave variables recovered faster and to a greater extent than did torque after the recovery intervals. We concluded that rapid recovery intervals between FES-evoked exercise sessions can radically interfere in the use of m-waves as a proxy for torque estimation in individuals with SCI. This needs to be further investigated, in addition to seeking a better understanding of the mechanisms of muscle fatigue and recovery.

  19. Effect of scorpion venom analgesic active peptide extracted from Buthus martensii Karsch on evoked potential in the thalamic posterior nucleus group in rats

    Institute of Scientific and Technical Information of China (English)

    Qiuhong Lin; Xinxin Li

    2008-01-01

    BACKGROUND: Buthus martensii Karsch is a rare medicinal animal, and dried integral Buthus martensii Karsch is an important drug in traditional Chinese medicine. OBJECTIVE: To investigate the effects of scorpion venom analgesic active peptide (SAP) extracted from Buthus martensii Karsch on evoked unit discharge of the common peroneal nerve in the posterior nucleus group of the thalamus using a stereotaxic electrophysiological extracellular microelectrode recording. DESIGN, TIME AND SETTING: One-way designed study, performed in the Physiological Laboratory of Shenyang Medical College on September 15, 2006. MATERIALS: Fifty 3-4 months old Wistar rats (25 males and 25 females) were used. SAP was provided by Shenyang Pharmaceutical University. Morphine solution was made by the First Drug Manufactory, Northeastern Drug Manufacture Group (batch number: H20013351). Naloxone solution was made by Hunan Pharmaceutical Co., Ltd. (batch number: H43021669). Type ATAC-350 medical data processing equipment was made by the Photoelectricity Company, Japan.MAIN OUTCOME MEASURES: Evoked discharge in the posterior nucleus group of the thalamus and effects of SAP alone and SAP in combination with saline, morphine, or naloxone on discharges in the posterior nucleus group of the thalamus as measured by TQ-19 medical data processing equipment.RESULTS: SAP group: At 1-3 minutes after SAP injection, evoked discharges in the posterior nucleus group of the thalamus were inhibited, and the inhibitory time lasted for (45.0?.7) minutes. Saline group: Evoked discharges in the posterior nucleus group of the thalamus did not change after saline injection. Morphine group: At 1-3 minutes after morphine injection, evoked discharges in the posterior nucleus group of the thalamus were inhibited, and the inhibitory time lasted for (35.0?.8) minutes. Naloxone group: SAP had no effects on evoked potentials in the posterior nucleus group of the thalamus.

  20. Role of motor evoked potentials in diagnosis of cauda equina and lumbosacral cord lesions.

    Science.gov (United States)

    Di Lazzaro, V; Pilato, F; Oliviero, A; Saturno, E; Dileone, M; Tonali, P A

    2004-12-28

    To determine the diagnostic value of motor evoked potentials (MEPs) in the diagnosis of lumbosacral cord disorders. MEPs in 37 patients with sensory and motor deficits in the lower limbs were studied. MRI demonstrated spinal cord involvement in 10 patients and cauda equina lesions in 27 patients. A double determination of central motor conduction time (CMCT), calculated as the difference between the latencies of responses evoked by cortical and paravertebral magnetic stimulation and as the difference between the latency of cortical MEP and the total peripheral conduction time calculated from the F-wave latency, enabled discrimination between a delay along the proximal root and a delay along the corticospinal tract. An abnormality of the CMCT calculated with both techniques is indicative of central motor pathway damage, whereas an abnormality of the CMCT calculated from the latency of responses evoked by paravertebral magnetic stimulation associated with a normal CMCT calculated from the F-wave latency suggests a cauda equina lesion. Neurophysiologic findings strongly correlated with the lesion site documented by MRI (cauda equina or lumbosacral cord). All patients with MR evidence of cord involvement had an abnormality of CMCT calculated with both methods, suggesting a lesion of central motor pathways. Clinical examination often failed to document a spinal cord lesion, suggesting pure peripheral involvement in 5 of the 10 patients with MR evidence of cord lesion. Motor evoked potential recording is an accurate and easily applicable test for the diagnosis of lumbosacral spinal cord lesions.

  1. Characterization of music-evoked autobiographical memories.

    Science.gov (United States)

    Janata, Petr; Tomic, Stefan T; Rakowski, Sonja K

    2007-11-01

    Despite music's prominence in Western society and its importance to individuals in their daily lives, very little is known about the memories and emotions that are often evoked when hearing a piece of music from one's past. We examined the content of music-evoked autobiographical memories (MEAMs) using a novel approach for selecting stimuli from a large corpus of popular music, in both laboratory and online settings. A set of questionnaires probed the cognitive and affective properties of the evoked memories. On average, 30% of the song presentations evoked autobiographical memories, and the majority of songs also evoked various emotions, primarily positive, that were felt strongly. The third most common emotion was nostalgia. Analyses of written memory reports found both general and specific levels of autobiographical knowledge to be represented, and several social and situational contexts for memory formation were common across many memories. The findings indicate that excerpts of popular music serve as potent stimuli for studying the structure of autobiographical memories.

  2. Foot amputation - discharge

    Science.gov (United States)

    Amputation - foot - discharge; Trans-metatarsal amputation - discharge ... You have had a foot amputation. You may have had an accident, or your foot may have had an infection or disease and doctors could not save ...

  3. Vestibular evoked myogenic potentials in patients with ankylosing spondylitis.

    Science.gov (United States)

    Özgür, Abdulkadir; Serdaroğlu Beyazal, Münevver; Terzi, Suat; Coşkun, Zerrin Özergin; Dursun, Engin

    2016-10-01

    Ankylosing spondylitis (AS) is a chronic systemic inflammatory disease with unknown etiology. Although sacroiliac joint involvement is the classic sign along with the formed immune mediators, it may result in immune-mediated inner ear disease and may cause damage to the audiovestibular system. Vestibular evoked myogenic potentials (VEMP) is a clinical reflex test used in the diagnosis of vestibular diseases and is performed by recording and evaluating the muscle potentials resulting from the stimulation of the vestibular system with different stimuli. The aim of this study is to evaluate the cervical VEMP test results in AS patients without vestibular symptoms. Thirty-three patients with AS and a control group of 30 healthy volunteers with similar demographic characteristics were evaluated in the study. VEMP wave latency, P13-N23 wave amplitude, and VEMP asymmetry ratio (VAR) values were compared between the groups. The relationship between clinical and laboratory findings of the AS patients and VEMP data were also investigated. Compared with healthy people, this study shows the response rate of patients with ankylosing spondylitis was reduced in the VEMP test, and P13-N23 wave amplitude showed a decrease in AS patients who had VEMP response (p ankylosing spondylitis. The data obtained from this study suggest that AS may lead to decreased sensitivity of the vestibular system.

  4. Brainstem auditory-evoked potentials in two meditative mental states

    Directory of Open Access Journals (Sweden)

    Kumar Sanjay

    2010-01-01

    Full Text Available Context: Practicing mental repetition of "OM" has been shown to cause significant changes in the middle latency auditory-evoked potentials, which suggests that it facilitates the neural activity at the mesencephalic or diencephalic levels. Aims: The aim of the study was to study the brainstem auditory-evoked potentials (BAEP in two meditation states based on consciousness, viz. dharana, and dhyana. Materials and Methods: Thirty subjects were selected, with ages ranging from 20 to 55 years (M=29.1; ±SD=6.5 years who had a minimum of 6 months experience in meditating "OM". Each subject was assessed in four sessions, i.e. two meditation and two control sessions. The two control sessions were: (i ekagrata, i.e. single-topic lecture on meditation and (ii cancalata, i.e. non-targeted thinking. The two meditation sessions were: (i dharana, i.e. focusing on the symbol "OM" and (ii dhyana, i.e. effortless single-thought state "OM". All four sessions were recorded on four different days and consisted of three states, i.e. pre, during and post. Results: The present results showed that the wave V peak latency significantly increased in cancalata, ekagrata and dharana, but no change occurred during the dhyana session. Conclusions: These results suggested that information transmission along the auditory pathway is delayed during cancalata, ekagrata and dharana, but there is no change during dhyana. It may be said that auditory information transmission was delayed at the inferior collicular level as the wave V corresponds to the tectum.

  5. Brain correlates of music-evoked emotions.

    Science.gov (United States)

    Koelsch, Stefan

    2014-03-01

    Music is a universal feature of human societies, partly owing to its power to evoke strong emotions and influence moods. During the past decade, the investigation of the neural correlates of music-evoked emotions has been invaluable for the understanding of human emotion. Functional neuroimaging studies on music and emotion show that music can modulate activity in brain structures that are known to be crucially involved in emotion, such as the amygdala, nucleus accumbens, hypothalamus, hippocampus, insula, cingulate cortex and orbitofrontal cortex. The potential of music to modulate activity in these structures has important implications for the use of music in the treatment of psychiatric and neurological disorders.

  6. Evoking prescribed spike times in stochastic neurons

    Science.gov (United States)

    Doose, Jens; Lindner, Benjamin

    2017-09-01

    Single cell stimulation in vivo is a powerful tool to investigate the properties of single neurons and their functionality in neural networks. We present a method to determine a cell-specific stimulus that reliably evokes a prescribed spike train with high temporal precision of action potentials. We test the performance of this stimulus in simulations for two different stochastic neuron models. For a broad range of parameters and a neuron firing with intermediate firing rates (20-40 Hz) the reliability in evoking the prescribed spike train is close to its theoretical maximum that is mainly determined by the level of intrinsic noise.

  7. Analysis of brain-stem auditory evoked potential and visual evoked potential in patients with Parkinson disease

    Institute of Scientific and Technical Information of China (English)

    Qiaorong Deng; Jianzhong Deng; Yanmin Zhao; Xiaohai Yan; Pin Chen

    2006-01-01

    BACKGROUND: With the development of neuroelectrophysiology, it had been identified that all kinds of evoked potentials might reflect the functional status of corresponding pathway. Evoked potentials recruited in the re search of PD, it can be known whether other functional pathway of nervous system is impaired. OBJECTIVE: To observe whether brainstem auditory and visual passageway are impaired in patients with Parkinson disease (PD), and compare with non-PD patients concurrently. DESIGN: A non-randomized concurrent controlled observation. SETTINGS: Henan Provincial Tumor Hospital; Anyang District Hospital. PARTICIPANTS: Thirty-two cases of PD outpatients and inpatients, who registered in the Department of Neurology, Anyang District Hospital from October 1997 to February 2006, were enrolled as the PD group, including 20 males and 12 females, aged 50-72 years old. Inclusive criteria: In accordance with the diagnostic criteria of PD recommended by the dyskinesia and PD group of neurology branch of Chinese Medical Association. Patients with diseases that could cause Parkinson syndrome were excluded by CT scanning or MRI examination. Meanwhile, 30 cases with non-neurological disease were selected from the Department of Internal Medicine of our hospital as the control group, including 19 males and 11 females, aged 45-70 years old. Including criteria: Without history of neurological disease or psychiatric disease; showing normal image on CT. And PD, Parkinson syndrome and Parkinsonism-plus were excluded by professional neurologist. All the patients were informed and agreed with the examination and clinical observation. METHODS: The electrophysiological examination and clinical observation of the PD patients and controls were conducted. The Reporter type 4-channel evoked potential machine (Italy) was used to check brain-stem auditory evoked potential (BAEP) and visual evoked potential (VEP). Why to be examined was explained to test taker. BAEP recording electrode was plac

  8. Value of somatosensory evoked potentials in diagnosis, surgical monitoring and prognosis of cervical spondylotic myelopathy

    Institute of Scientific and Technical Information of China (English)

    DING Yu; HU Yong; RUAN Di-ke; CHEN Bo

    2008-01-01

    Background The value of somatosensory evoked potentials (SEPs) in the diagnosis and prognosis of cervical spondylotic myelopathy, as well as the usefulness of monitoring intraoperative potentials in terms of safety and predictive factors were investigated.Methods Each of the 76 myelopathic patients underwent surgical intervention. According to the wave configurations of the SEPs, the cases were categorised into four groups: Type Ⅰ, Ⅱ, Ⅲ and Ⅳ. The clinical myelopathy disability was classified and the severity of neurological deficits was scored. Clinical function after surgery was evaluated. Preoperative potentials and intraoperative monitoring were categorized. The correlations between evoked potentials detection, monitoring, myelopathy disability and surgical outcome in the different groups were discussed. Results According to the configurations of the SEPs, there were 27 patients (36%) of Type Ⅰ, 30 patients (39%) of Type Ⅱ, 8 patients (11%) of Type Ⅲ, and 11 patients (14%) of Type Ⅳ. The categorised evoked potentials were shown to be significantly associated with the clinical representation of myelopathy (P 〈0.01) and the recovery rate from identifiable SEPs waves (groups A, B and C) was significantly higher than unidentifiable waves (group D, P〈0.01). A deterioration of SEPs was detected in 23 cases (30%), whereas there was no change in 40 cases (53%) and improvements in 13 cases (17%). A significant difference in recovery rates could be observed in various monitoring groups within the short-term follow-up period, while there were no obvious differences in the long-term follow-up groups. Conclusions SEP technique is a valuable and practical tool for the diagnosis, monitoring and prognosis of myelopathy. Classified evoked potentials are well correlated with cervical spondyiotic myelopathy disability, and unidentifiable SEPs waves in patients are indicative of a relatively poor outcome. In addition, intraoperative monitoring of SEPs plays an

  9. 0 to 5 year-old children hearing appraisal by encephalic trunk audition evoked potentials

    OpenAIRE

    Bustamante Mejía, César; Unidad de Otoneurología, Sección Otorrinolaringología, Hospital Central de la Fuerza Aérea del Perú, Lima, Perú

    2014-01-01

    OBJECTIVE: To analyze hearing development and maturation from 0 to 5 years of age by evaluating latency times with encephalic trunk audition evoked potentials (AEP). MATERIAL AND METHODS: Forty-four 0 to 5 year-old patients were grouped by age and AEP performed with identical parameters; all patients were sedated to avoid interference. RESULTS: Latency times decreased as age increased, denoting age/latency time (V wave) relation as indicator of hearing development and maturation. CONclusiOn: ...

  10. Enhancement of the amplitude of somatosensory evoked potentials following magnetic pulse stimulation of the human brain.

    Science.gov (United States)

    Seyal, M; Browne, J K; Masuoka, L K; Gabor, A J

    1993-01-01

    In this study we have demonstrated an enhancement of cortically generated wave forms of the somatosensory evoked potential (SEP) following magnetic pulse stimulation of the human brain. Subcortically generated activity was unaltered. The enhancement of SEP amplitude was greatest when the median nerve was stimulated 30-70 msec following magnetic pulse stimulation over the contralateral parietal scalp. We posit that the enhancement of the SEP is the result of synchronization of pyramidal cells in the sensorimotor cortex resulting from the magnetic pulse.

  11. Air pollution is associated with brainstem auditory nuclei pathology and delayed brainstem auditory evoked potentials

    OpenAIRE

    Calderón-Garcidueñas, Lilian; D’Angiulli, Amedeo; Kulesza, Randy J.; Torres-Jardón, Ricardo; Osnaya, Norma; Romero, Lina; Keefe, Sheyla; Herritt, Lou; Brooks, Diane M.; Avila-Ramirez, Jose; Delgado-Chávez, Ricardo; Medina-Cortina, Humberto; González-González, Luis Oscar

    2011-01-01

    We assessed brainstem inflammation in children exposed to air pollutants by comparing brainstem auditory evoked potentials (BAEPs) and blood inflammatory markers in children age 96.3± 8.5 months from highly polluted (n=34) versus a low polluted city (n=17). The brainstems of nine children with accidental deaths were also examined. Children from the highly polluted environment had significant delays in wave III (t(50)=17.038; p

  12. [Visual evoked potentials produced by monocular flash stimuli in the cerebral cortex of the rabbit. I. Typography].

    Science.gov (United States)

    Pérez-Cobo, J C; Ruiz-Beramendi, M; Pérez-Arroyo, M

    1990-12-01

    The visually evoked potentials in the hemisphere contralateral to the stimulated eye in rabbit, can be described topographically as follows. While a positive wave (P1) begins forming in the anterior zones and in the V I binocular zone, the N0 wave, at times very large, is produced in a more occipital zone, which corresponds to the visual streak. Immediately afterwards, the positivity, P1, practically invades the whole of the hemisphere. After this, the N1 wave which is produced in the most posterior parts of the V I, begins forming. The whole phenomenon comes to an end when the P2 wave is generated in the most occipital zones.

  13. Changes in somatosensory evoked potentials elicited by stimulation of upper-limb and lower-limb nerves in amyotrophic lateral sclerosis patients

    Institute of Scientific and Technical Information of China (English)

    Ying Zheng; Zhaohuan Zhang; Weihua Wu; Zhongxin Zhao

    2011-01-01

    This study observed the changes in somatosensory evoked potentials between patients with amyotrophic lateral sclerosis (ALS) and healthy controls to evaluate the function of the central deep somatosensory pathway. In patients with ALS, 28 patients (54%) showed an abnormality in somatosensory evoked potentials. All had abnormal lower limb somatosensory evoked potentials. Compared with healthy controls, the abnormality in somatosensory evoked potential was characterized by prolonged N20, P2, N2 latency and central conduction time, with or without a decrease in wave amplitude or disappearance of waveform. Results showed marked alterations in the somatosensory evoked potential in cortical components of the upper and lower limb in 54% of patients with ALS, and confirmed that patients with ALS may also have a defective deep somatosensory pathway, particularly an abnormal central deep somatosensory pathway.

  14. Newborn hearing screening by transient evoked otoacoustic emissions: analysis of response as a function of risk factors.

    Science.gov (United States)

    De Capua, B; De Felice, C; Costantini, D; Bagnoli, F; Passali, D

    2003-02-01

    Hearing loss can be considered as the most common birth defect. Early detection of hearing loss by screening at, or shortly after, birth and appropriate intervention are critical to speech, language and cognitive development. In the present study, the characteristics of Transient Evoked Otoacoustic Emissions have been evaluated as a function of known pre- and perinatal risk factors for hearing loss. All newborns were screened for hearing loss using a physiologic test of hearing function, the Transient Evoked Otoacoustic Emissions. A total of 532 consecutive newborn infants received binaural Transient Evoked Otoacoustic Emission testing (262 males, 270 females; mean gestational age 39.2 +/- 2.1 weeks, range 26-43; birth weight: 3,240 +/- 550 g, range 910-4,780). The population examined comprised 448 control infants and 84 high-risk for hearing loss infants (Joint Committee on Infant Hearing 1994 criteria). All Transient Evoked Otoacoustic Emission recordings were performed at comparable postconceptional ages. Audiological screening by Transient Evoked Otoacoustic Emission recording showed an overall 100% sensitivity, 99.02% specificity, with negative and positive predictive values of 100% and 62.5%, respectively. As compared to controls, high-risk infants showed: 1. increased rates of Fail-1 (Transient Evoked Otoacoustic Emissions absent at first examination, 21.4% vs 9.8%, p = 0.004), Fail-2 (Transient Evoked Otoacoustic Emissions absent on retesting: 8.64% vs 1.37%, p = 0.0014), false positives (Transient Evoked Otoacoustic Emissions absent/V wave present: 3.7% vs 0.46%, p = 0.029) and true positives (Transient Evoked Otoacoustic Emissions absent, V wave absent: 2.47% or 24.5 per 1,000 live births vs 0.22% or 2.2 per 1,000 live births, p = 0.013); 2. significantly reduced Transient Evoked Otoacoustic Emission intensity in the 0.7-1 kHz (right side) and 1-2 kHz (left side) frequency ranges. Multivariate logistic regression analysis showed a significant positive

  15. [Effect of sleep deprivation on visual evoked potentials and brain stem auditory evoked potentials in epileptics].

    Science.gov (United States)

    Urumova, L T; Kovalenko, G A; Tsunikov, A I; Sumskiĭ, L I

    1984-01-01

    The article reports on the first study of the evoked activity of the brain in epileptic patients (n = 20) following sleep deprivation. An analysis of the data obtained has revealed a tendency to the shortening of the peak latent intervals of visual evoked potentials in the range of 100-200 mu sec and the V component and the interpeak interval III-V of evoked auditory trunk potentials in patients with temporal epilepsy. The phenomenon may indicate the elimination of stabilizing control involving the specific conductive pathways and, possibly, an accelerated conduction of a specific sensor signal.

  16. Color Evoked Potentials in Adults and Infants.

    Science.gov (United States)

    White, Carroll T.; And Others

    This paper discusses recent studies of the adult visual evoked potential (VEP) which have indicated that specific components of the complex waveform obtained are related to the three basic color processes, and that these components interact in ways that seem to agree with opponent-colors phenomena. The components identified as being related to the…

  17. Methylglyoxal evokes pain by stimulating TRPA1.

    Directory of Open Access Journals (Sweden)

    David A Andersson

    Full Text Available Diabetic neuropathy is a severe complication of long-standing diabetes and one of the major etiologies of neuropathic pain. Diabetes is associated with an increased formation of reactive oxygen species and the electrophilic dicarbonyl compound methylglyoxal (MG. Here we show that MG stimulates heterologously expressed TRPA1 in CHO cells and natively expressed TRPA1 in MDCK cells and DRG neurons. MG evokes [Ca(2+]i-responses in TRPA1 expressing DRG neurons but is without effect in neurons cultured from Trpa1(-/- mice. Consistent with a direct, intracellular action, we show that methylglyoxal is significantly more potent as a TRPA1 agonist when applied to the intracellular face of excised membrane patches than to intact cells. Local intraplantar administration of MG evokes a pain response in Trpa1(+/+ but not in Trpa1(-/- mice. Furthermore, persistently increased MG levels achieved by two weeks pharmacological inhibition of glyoxalase-1 (GLO-1, the rate-limiting enzyme responsible for detoxification of MG, evokes a progressive and marked thermal (cold and heat and mechanical hypersensitivity in wildtype but not in Trpa1(-/- mice. Our results thus demonstrate that TRPA1 is required both for the acute pain response evoked by topical MG and for the long-lasting pronociceptive effects associated with elevated MG in vivo. In contrast to our observations in DRG neurons, MG evokes indistinguishable [Ca(2+]i-responses in pancreatic β-cells cultured from Trpa1(+/+ and Trpa1(-/- mice. In vivo, the TRPA1 antagonist HC030031 impairs glucose clearance in the glucose tolerance test both in Trpa1(+/+ and Trpa1(-/- mice, indicating a non-TRPA1 mediated effect and suggesting that results obtained with this compound should be interpreted with caution. Our results show that TRPA1 is the principal target for MG in sensory neurons but not in pancreatic β-cells and that activation of TRPA1 by MG produces a painful neuropathy with the behavioral hallmarks of diabetic

  18. Combined ocular and cervical vestibular evoked myogenic potential in individuals with vestibular hyporeflexia and in patients with Ménière's disease.

    Science.gov (United States)

    Silva, Tatiana Rocha; de Resende, Luciana Macedo; Santos, Marco Aurélio Rocha

    The vestibular evoked myogenic potential is a potential of mean latency that measures the muscle response to auditory stimulation. This potential can be generated from the contraction of the sternocleidomastoid muscle and also from the contraction of extraocular muscles in response to high-intensity sounds. This study presents a combined or simultaneous technique of cervical and ocular vestibular evoked myogenic potential in individuals with changes in the vestibular system, for use in otoneurologic diagnosis. To characterize the records and analyze the results of combined cervical and ocular VEMP in individuals with vestibular hyporeflexia and in those with Ménière's disease. The study included 120 subjects: 30 subjects with vestibular hyporeflexia, 30 with Ménière's disease, and 60 individuals with normal hearing. Data collection was performed by simultaneously recording the cervical and ocular vestibular evoked myogenic potential. There were differences between the study groups (individuals with vestibular hyporeflexia and individuals with Ménière's disease) and the control group for most of wave parameters in combined cervical and ocular vestibular evoked myogenic potential. For cervical vestibular evoked myogenic potential, it was observed that the prolongation of latency of the P13 and N23 waves was the most frequent finding in the group with vestibular hyporeflexia and in the group with Ménière's disease. For ocular vestibular evoked myogenic potential, prolonged latency of N10 and P15 waves was the most frequent finding in the study groups. Combined cervical and ocular vestibular evoked myogenic potential presented relevant results for individuals with vestibular hyporeflexia and for those with Ménière's disease. There were differences between the study groups and the control group for most of the wave parameters in combined cervical and ocular vestibular evoked myogenic potential. Copyright © 2016 Associação Brasileira de Otorrinolaringologia

  19. Electric field in an AC dielectric barrier discharge overlapped with a nanosecond pulse discharge

    Science.gov (United States)

    Goldberg, Benjamin M.; Shkurenkov, Ivan; Adamovich, Igor V.; Lempert, Walter R.

    2016-08-01

    The effect of ns discharge pulses on the AC barrier discharge in hydrogen in plane-to-plane geometry is studied using time-resolved measurements of the electric field in the plasma. The AC discharge was operated at a pressure of 300 Torr at frequencies of 500 and 1750 Hz, with ns pulses generated when the AC voltage was near zero. The electric field vector is measured by ps four-wave mixing technique, which generates coherent IR signal proportional to the square of electric field. Absolute calibration was done using an electrostatic (sub-breakdown) field applied to the discharge electrodes, when no plasma was generated. The results are compared with one-dimensional kinetic modeling of the AC discharge and the nanosecond pulse discharge, predicting behavior of both individual micro-discharges and their cumulative effect on the electric field distribution in the electrode gap, using stochastic averaging based on the experimental micro-discharge temporal probability distribution during the AC period. Time evolution of the electric field in the AC discharge without ns pulses, controlled by a superposition of random micro-discharges, exhibits a nearly ‘flat top’ distribution with the maximum near breakdown threshold, reproduced quite well by kinetic modeling. Adding ns pulse discharges on top of the AC voltage waveform changes the AC discharge behavior in a dramatic way, inducing transition from random micro-discharges to a more regular, near-1D discharge. In this case, reproducible volumetric AC breakdown is produced at a well-defined moment after each ns pulse discharge. During the reproducible AC breakdown, the electric field in the plasma exhibits a sudden drop, which coincides in time with a well-defined current pulse. This trend is also predicted by the kinetic model. Analysis of kinetic modeling predictions shows that this effect is caused by large-volume ionization and neutralization of surface charges on the dielectrics by ns discharge pulses. The present

  20. Chronic obstructive pulmonary disease - adults - discharge

    Science.gov (United States)

    COPD - adults - discharge; Chronic obstructive airways disease - adults - discharge; Chronic obstructive lung disease - adults - discharge; Chronic bronchitis - adults - discharge; Emphysema - adults - discharge; Bronchitis - ...

  1. Plasma production by means of discharge in a spherical cavity

    NARCIS (Netherlands)

    Antsiferov, P. S.; Dorokhin, L. A.; Koshelev, K. N.

    2010-01-01

    The work is devoted to the study of plasma, appearing as a result of cumulation of shock wave with form close to spherical. The shock wave was obtained by triggering of fast discharge (dI/dt about 10(12) A/s) on inner surface of cavity, made from insulator. Spherical cavity with radius 4.5 mm was fi

  2. The temporal relationship between the brainstem and primary cortical auditory evoked potentials.

    Science.gov (United States)

    Shaw, N A

    1995-10-01

    Many methods are employed in order to define more precisely the generators of an evoked potential (EP) waveform. One technique is to compare the timing of an EP whose origin is well established with that of one whose origin is less certain. In the present article, the latency of the primary cortical auditory evoked potential (PCAEP) was compared to each of the seven subcomponents which compose the brainstem auditory evoked potential (BAEP). The data for this comparison was derived from a retrospective analysis of previous recordings of the PCAEP and BAEP. Central auditory conduction time (CACT) was calculated by subtracting the latency of the cochlear nucleus BAEP component (wave III) from that of the PCAEP. It was found that CACT in humans is 12 msec which is more than double that of central somatosensory conduction time. The interpeak latencies between BAEP waves V, VI, and VII and the PCAEP were also calculated. It was deduced that all three waves must have an origin rather more caudally within the central auditory system than is commonly supposed. In addition, it is demonstrated that the early components of the middle latency AEP (No and Na) largely reside within the time domain between the termination of the BAEP components and the PCAEP which would be consistent with their being far field reflections of midbrain and subcortical auditory activity. It is concluded that as the afferent volley ascends the central auditory pathways, it generates not a sequence of high frequency BAEP responses but rather a succession of slower post-synaptic waves. The only means of reconciling the timing of the BAEP waves with that of the PCAEP is to assume that the generation of all the BAEP components must be largely restricted to a quite confined region within the auditory nerve and the lower half of the pons.

  3. Cervical vestibular evoked myogenic potentials and caloric test results in individuals with auditory neuropathy spectrum disorders.

    Science.gov (United States)

    Sujeet, Kumar Sinha; Niraj, Kumar Singh; Animesh, Barman; Rajeshwari, G; Sharanya, R

    2014-01-01

    Auditory neuropathy spectrum disorder is a type of hearing loss where outer hair cell function are normal (as evidenced by the preservation of OAEs and cochlear microphonics), whereas auditory nerve functions are abnormal (as evidenced by abnormal auditory brainstem evoked potentials beginning with wave I of the ABR) and acoustic reflexes to ipsilateral and contralateral tones are absent. It is likely that in cases with auditory neuropathy spectrum disorder not only the cochlear nerve, but also the vestibular nerves might get involved. The present study was conducted with an aim of finding out the inferior and superior vestibular nerve involvement through cervical vestibular evoked myogenic potentials and Caloric test results respectively in individuals with Auditory Neuropathy Spectrum Disorders. Total 26 participants who fulfilled the criteria of auditory neuropathy spectrum disorder participated for the study. Vestibular evoked myogenic potentials results showed absence of responses from most of the subjects also caloric responses showed bilateral hypofunctional responses in most of the participants, which is suggestive of involvement of both the inferior as well as superior vestibular nerve in individuals with auditory neuropathy spectrum disorders. Additionally there was no association between the pattern and degree of hearing loss to caloric test results and vestibular evoked myogenic potentials results findings.

  4. Visual, auditory, and somatosensorial evoked potentials in early and late treated adolescents with phenylketonuria.

    Science.gov (United States)

    Leuzzi, V; Cardona, F; Antonozzi, I; Loizzo, A

    1994-11-01

    Pattern reversal visual, auditory, and somatosensorial evoked potentials were recorded in two groups of phenylketonuric (PKU) adolescents after protracted exposition to high concentrations of phenylalanine following diet discontinuation. The first group consisted of 11 early treated (before age 3 months) PKU patients (ET-PKU); the second group consisted of 11 late detected (after age 8 months), symptomatic, PKU subjects (LT-PKU). Despite the relevant lag between the two groups in mental development and neurological status, no clear-cut difference in evoked potentials could be detected. Only the wave I latency of the brainstem auditory evoked potentials (BAEPs) was significantly shorter in ET- versus LT-PKU children. The P100 latency, I-V interpeak latency (IPL), and I-III IPL seem to discriminate the less severe form of PKU (ET-PKU type 3) from the most severe forms, ET-PKU type 1 plus 2 and LT-PKU. No correlations were found between clinical, biochemical, and neurophysiological parameters. The present data suggest that evoked potentials technique is of limited sensitivity in detecting central nervous system (CNS) alterations in PKU adolescents after diet discontinuation.

  5. Wave analysis of the evolution of a single wave packet in supersonic boundary layer

    Science.gov (United States)

    Yermolaev, Yury G.; Yatskikh, Aleksey A.; Kosinov, Alexander D.; Semionov, Nickolay V.

    2016-10-01

    The evolution of the artificial wave packet in laminar flat-plate boundary layer was experimentally studied by hot-wire measurements at M=2. The localized disturbances were generated by pulse glow discharge. The wave analysis of evolution of wave packet was provided. It was found, that the most unstable waves are oblique, that consistent with results of linear theory.

  6. Determination of discharge during pulsating flow

    Science.gov (United States)

    Thompson, T.H.

    1968-01-01

    Pulsating flow in an open channel is a manifestation of unstable-flow conditions in which a series of translatory waves of perceptible magnitude develops and moves rapidly downstream. Pulsating flow is a matter of concern in the design and operation of steep-gradient channels. If it should occur at high stages in a channel designed for stable flow, the capacity of the channel may be inadequate at a discharge that is much smaller than that for which the channel was designed. If the overriding translatory wave carries an appreciable part of the total flow, conventional stream-gaging procedures cannot be used to determine the discharge; neither the conventional instrumentation nor conventional methodology is adequate. A method of determining the discharge during pulsating flow was tested in the Santa Anita Wash flood control channel in Arcadia, Calif., April 16, 1965. Observations of the dimensions and velocities of translatory waves were made during a period of controlled reservoir releases of about 100, 200, and 300 cfs (cubic feet per second). The method of computing discharge was based on (1) computation of the discharge in the overriding waves and (2) computation of the discharge in the shallow-depth, or overrun, part of the flow. Satisfactory results were obtained by this method. However, the procedure used-separating the flow into two components and then treating the shallow-depth component as though it were steady--has no theoretical basis. It is simply an expedient for use until laboratory investigation can provide a satisfactory analytical solution to the problem of computing discharge during pulsating flow. Sixteen months prior to the test in Santa Anita Wash, a robot camera had been designed .and programmed to obtain the data needed to compute discharge by the method described above. The photographic equipment had been installed in Haines Creek flood control channel in Los Angeles, Calif., but it had not been completely tested because of the infrequency of

  7. Early visual evoked potentials in callosal agenesis.

    Science.gov (United States)

    Barr, Melodie S; Hamm, Jeff P; Kirk, Ian J; Corballis, Michael C

    2005-11-01

    Three participants with callosal agenesis and 12 neurologically normal participants were tested on a simple reaction time task, with visual evoked potentials collected using a high-density 128-channel system. Independent-components analyses were performed on the averaged visual evoked potentials to isolate the components of interest. Contrary to previous research with acallosals, evidence of ipsilateral activation was present in all 3 participants. Although ipsilateral visual components were present in all 4 unilateral conditions in the 2 related acallosal participants, in the 3rd, these were present only in the crossed visual field-hand conditions and not in the uncrossed conditions. Suggestions are made as to why these results differ from earlier findings and as to the neural mechanisms facilitating this ipsilateral activation.

  8. Thought-evoking approaches in engineering problems

    CERN Document Server

    2014-01-01

    In creating the value-added product in not distant future, it is necessary and inevitable to establish a holistic and though-evoking approach to the engineering problem, which should be at least associated with the inter-disciplinary knowledge and thought processes across the whole engineering spheres. It is furthermore desirable to integrate it with trans-disciplinary aspects ranging from manufacturing culture, through liberal-arts engineering, and industrial sociology.   The thought-evoking approach can be exemplified and typified by representative engineering problems: unveiling essential features in ‘Tangential Force Ratio and Interface Pressure’, prototype development for ‘Bio-mimetic Needle’ and application of ‘Water-jet Machining to Artificial Hip Joint’, product innovation in ‘Heat Sink for Computer’, application of ‘Graph Theory’ to similarity evaluation of production systems, leverage among reciprocity attributes in ‘Industrial and Engineering Designs for Machine Enclosure’,...

  9. Spatial Tuning Studies of the Pattern Evoked Electroretinogram.

    Science.gov (United States)

    Thompson, Dorothy Ann

    1987-09-01

    Available from UMI in association with The British Library. The locus of origin of the pattern evoked electroretinogram, (PERG), has been the subject of considerable discussion. A novel approach was adopted in this study to further elaborate the nature of the PERG evoked by pattern onset/offset presentation. The PERG was found to be linearly related to stimulus contrast and in particular was linearly related to the temporal contrast of the retinal image, when elicited by patterns of low spatial frequency. At high spatial frequencies the retinal image contrast is significantly reduced because of optical degradation. This is described by the eye's modulation transfer function (MTF). The retinal contrasts of square wave grating and chequerboard patterns of increasing spatial frequency were found by filtering their Fourier transforms by the MTF. The filtered pattern harmonics were then resynthesised to constitute a profile of retinal image illuminance from which the temporal and spatial contrast of the image could be calculated. A space-averaged temporal contrast attenuation factor was applied to PERGs evoked by low spatial frequency patterns to predict the retinal illuminance response elicited by a finer pattern. The predicted response was subtracted from the recorded signal and the residual waveform was proposed to represent pattern specific activity. An additional correction for the attenuation of spatial contrast was applied to the extracted pattern specific response. Pattern specific responses are the predicted result of iso-contrast retinal pattern stimulation. The pattern specific responses demonstrate a striking bandpass spatial selectivity which peaks at higher spatial frequencies in the more central retina. The variation of spatial sensitivity with eccentricity corresponds closely with estimated ganglion receptive field centre separation and psychophysical data. The variation of retinal structure with eccentricity in the form of the volumes of the nuclear

  10. Inhibition of midbrain-evoked tonic and rhythmic motor activity by cutaneous stimulation in decerebrate cats.

    Science.gov (United States)

    Beyaert, C A; Haouzi, P; Marchal, F

    2003-03-01

    The effect of mechanical and electrical stimulation of cervical cutaneous afferents was analysed on both the centrally induced tonic and rhythmic activities in hindlimb antagonist muscle nerves of 16 decerebrate paralysed cats. Electrical stimulation of dorsal midbrain evoked in the nerve to the tibialis anterior muscle (TAn) either rhythmic discharges (n=14), associated with tonic discharges in ten cats, or only tonic discharges (n=4). Centrally induced activity in the ipsilateral nerve to gastrocnemius medialis (GMn) occurred in fewer cats (n=12) and displayed similar patterns as in TAn. Manual traction of the scruff of the neck reduced the TAn tonic and rhythmic discharges (n=6) by 73% (P<0.05) and 71% (P<0.05), respectively, and reduced only the tonic component of GMn discharges (by 41%, n=3). Electrical stimulation (impulses 0.1-0.5 ms, 50 Hz) of cervical nerves belonging to C5 or C6 dermatomes, the intensity (0.4-4 mA) of which induced minimal inhibition of both TAn and GMn discharges, reduced significantly the tonic component of TAn discharges (by 39%, n=4). At higher intensities of electrical cervical nerve stimulation (2-6 mA) inducing maximal inhibitory effect, both tonic and rhythmic activities in TAn and GMn were both significantly reduced by, respectively, 81% and 94% in TAn (n=7), and by 49% and 43% in GMn (n=7). Electrical cervical nerve stimulation consistently reduced the isolated tonic discharge in TAn by 66% (n=4, P<0.05) and in GMn by 23% (n=3) when present. Thus the tonic component was more sensitive to inhibition than the rhythmic component of hindlimb muscle nerve activity.

  11. Auditory evoked potentials and multiple sclerosis

    OpenAIRE

    Carla Gentile Matas; Sandro Luiz de Andrade Matas; Caroline Rondina Salzano de Oliveira; Isabela Crivellaro Gonçalves

    2010-01-01

    Multiple sclerosis (MS) is an inflammatory, demyelinating disease that can affect several areas of the central nervous system. Damage along the auditory pathway can alter its integrity significantly. Therefore, it is important to investigate the auditory pathway, from the brainstem to the cortex, in individuals with MS. OBJECTIVE: The aim of this study was to characterize auditory evoked potentials in adults with MS of the remittent-recurrent type. METHOD: The study comprised 25 individuals w...

  12. Brain stem evoked response audiometry A Review

    OpenAIRE

    Balasubramanian Thiagarajan

    2015-01-01

    Brain stem evoked response audiometry (BERA) is a useful objective assessement of hearing. Major advantage of this procedure is its ability to test even infants in whom conventional audiometry may not be useful. This investigation can be used as a screening test for deafness in high risk infants. Early diagnosis and rehabilitation will reduce disability in these children. This article attempts to review the published literature on this subject. Methadology: Internet search using goog...

  13. Evoked Effective Connectivity of the Human Neocortex

    OpenAIRE

    Entz, László; Tóth, Emília; Keller, Corey J.; Bickel, Stephan; Groppe, David M.; Fabó, Dániel; Kozák, Lajos R.; Eroőss, Loránd; Ulbert, István; Mehta, Ashesh D.

    2014-01-01

    The role of cortical connectivity in brain function and pathology is increasingly being recognized. While in vivo magnetic resonance imaging studies have provided important insights into anatomical and functional connectivity, these methodologies are limited in their ability to detect electrophysiological activity and the causal relationships that underlie effective connectivity. Here, we describe results of cortico-cortical evoked potential (CCEP) mapping using single pulse electrical stimul...

  14. Evoked Brain Activity and Personnel Performance

    Science.gov (United States)

    1987-10-01

    Eysenck and Barrett (1985) reviewed at considerable length this error rate theory , as well as other proposed interactions of psychophysiology and...Include Security CItuification) EVOKED BRAIN ACTIVITY AND PERSONNEL PERFORMANCE 12 PERSONAL AUTHOR(S) Lewis, G. W., and Sorenson, R. C. 13a. TYPE...aptitude tests and the MM PI and other personality tests were developed along with tests designed for military purposes. The latter include the Armed

  15. Brainstem auditory evoked response: application in neurology

    Directory of Open Access Journals (Sweden)

    Carlos A. M. Guerreiro

    1982-03-01

    Full Text Available The tecnique that we use for eliciting brainstem auditory evoked responses (BAERs is described. BAERs are a non-invasive and reliable clinical test when carefully performed. This test is indicated in the evaluation of disorders which may potentially involve the brainstem such as coma, multiple sclerosis posterior fossa tumors and others. Unsuspected lesions with normal radiologic studies (including CT-scan can be revealed by the BAER.

  16. Glow discharge based device for solving mazes

    Energy Technology Data Exchange (ETDEWEB)

    Dubinov, Alexander E., E-mail: dubinov-ae@yandex.ru; Mironenko, Maxim S.; Selemir, Victor D. [Russian Federal Nuclear Center − All-Russian Scientific and Research Institute of Experimental Physics (RFNC-VNIIEF), Sarov, Nizhni Novgorod region 607188 (Russian Federation); Sarov Institute of Physics and Technology (SarFTI) of National Research Nuclear University “MEPhI,” Sarov, Nizhni Novgorod region 607188 (Russian Federation); Maksimov, Artem N.; Pylayev, Nikolay A. [Russian Federal Nuclear Center − All-Russian Scientific and Research Institute of Experimental Physics (RFNC-VNIIEF), Sarov, Nizhni Novgorod region 607188 (Russian Federation)

    2014-09-15

    A glow discharge based device for solving mazes has been designed and tested. The device consists of a gas discharge chamber and maze-transformer of radial-azimuth type. It allows changing of the maze pattern in a short period of time (within several minutes). The device has been tested with low pressure air. Once switched on, a glow discharge has been shown to find the shortest way through the maze from the very first attempt, even if there is a section with potential barrier for electrons on the way. It has been found that ionization waves (striations) can be excited in the maze along the length of the plasma channel. The dependancy of discharge voltage on the length of the optimal path through the maze has been measured. A reduction in discharge voltage with one or two potential barriers present has been found and explained. The dependency of the magnitude of discharge ignition voltage on the length of the optimal path through the maze has been measured. The reduction of the ignition voltage with the presence of one or two potential barriers has been observed and explained.

  17. 负偏压离子鞘及气体压强影响表面波放电过程的粒子模拟%Particle-in-cell simulation on surface-wave discharge pro cess influenced by gas pressure and negative-biased voltage along ion sheath layer

    Institute of Scientific and Technical Information of China (English)

    陈兆权; 胡希伟; 殷志祥; 陈明功; 刘明海; 徐公林; 胡业林; 夏广庆; 宋晓; 贾晓芬

    2014-01-01

    Due to surface electromagnetic waves propagating along the dielectric-plasma interface, the application of surface-wave plasma (SWP) is limited in view of the fact that it is very difficult to realize metal sputtering by using negative-biased voltage in traditional SWP sources. Recently, this problem is overcome by a type of SWP source based on the guided wave in ion sheath layer driven by negative-biased voltage. And the plasma heating mechanism is originated from gas discharges excited by the local-enhanced electric field of surface plasmon polariton (SPP). However, the best discharge condition is not obtained because the influence factors affecting the discharge process studied is not clear. In this paper, the discharge mechanism of SWP ionization process influenced by gas pressure and negative-biased voltage along the ion sheath layer is investigated. The simulation method is by means of combining particle-in-cell (PIC) with Monte Carlo collision (MCC). Simulated results suggest that the values of negative-biased voltage and gas pressure can influence the thickness of ion sheath layer, the excitation of SPP, and the spatio-temporal conversion of wave mode, which further induces the different discharge performances. Moreover, the discussed analysis states that a better discharge performance can be obtained when approximately a negative-biased voltage of-200 V and a gas pressure of 40 Pa applied.%由于表面电磁波沿着介质-等离子体分界面传播,而很难通过对传统的表面波等离子体(SWP)源施加负偏压实现金属材料溅射,因此限制了SWP源的使用范围。近期,一种基于负偏压离子鞘导波的SWP源克服了这个问题,且其加热机理是表面等离激元(SPP)的局域增强电场激励气体放电产生。但是该SWP源放电过程的影响因素并未研究清晰,导致其最佳放电条件没有获得。本文采用粒子(PIC)和蒙特卡罗碰撞(MCC)相结合的模拟方法,探讨了负偏压离子

  18. Predicting tile drainage discharge

    DEFF Research Database (Denmark)

    Iversen, Bo Vangsø; Kjærgaard, Charlotte; Petersen, Rasmus Jes;

    of the water load coming from the tile drainage system is therefore essential. This work aims at predicting tile drainage discharge using dynamic as well as a statistical predictive models. A large dataset of historical tile drain discharge data, daily discharge values as well as yearly average values were......More than 50 % of Danish agricultural areas are expected to be artificial tile drained. Transport of water and nutrients through the tile drain system to the aquatic environment is expected to be significant. For different mitigation strategies such as constructed wetlands an exact knowledge...... used in the analysis. For the dynamic modelling, a simple linear reservoir model was used where different outlets in the model represented tile drain as well as groundwater discharge outputs. This modelling was based on daily measured tile drain discharge values. The statistical predictive model...

  19. CO-AXIAL DISCHARGES

    Science.gov (United States)

    Luce, J.S.; Smith, L.P.

    1960-11-22

    A method and apparatus are given for producing coaxial arc discharges in an evacuated enclosure and within a strong, confining magnetic field. The arcs are maintained at a high potential difference. Electrons will diffuse to the more positive arc from the negative arc, and positive ions will diffuse from the more positive arc to the negative arc. Coaxial arc discharges have the advantage that ions which return to strike the positive arc discharge will lose no energy since they do not strike a solid wall or electrode. Those discharges are useful in confining an ionized plasma between the discharges, and have the advantage of preventing impurities from the walls of the enclosure from entering ihe plasma area because of the arc barrier set up bv the cylindrical outer arc.

  20. EFFECTIVE DISCHARGE CALCULATION GUIDE

    Institute of Scientific and Technical Information of China (English)

    D.S.BIEDENHARN; C.R.THORNE; P.J.SOAR; R.D.HEY; C.C.WATSON

    2001-01-01

    This paper presents a procedure for calculating the effective discharge for rivers with alluvial channels.An alluvial river adjusts the bankfull shape and dimensions of its channel to the wide range of flows that mobilize the boundary sediments. It has been shown that time-averaged river morphology is adjusted to the flow that, over a prolonged period, transports most sediment. This is termed the effective discharge.The effective discharge may be calculated provided that the necessary data are available or can be synthesized. The procedure for effective discharge calculation presented here is designed to have general applicability, have the capability to be applied consistently, and represent the effects of physical processes responsible for determining the channel, dimensions. An example of the calculations necessary and applications of the effective discharge concept are presented.

  1. [Early prognosis in severe cranio-cerebral trauma using the Glasgow Coma Score and evoked potentials].

    Science.gov (United States)

    Riffel, B; Stöhr, M; Graser, W; Trost, E; Baumgärtner, H

    1989-02-01

    During 72 h following severe head injury, 103 patients in acute posttraumatic coma were assessed by clinical examinations (documented by Glasgow Coma Score) and brain stem auditory evoked potentials (BAEP) as well as short-latency somatosensory evoked potentials (SEP) following median-nerve stimulation. Patient outcomes were classified at 6 months or more according to the following categories: good recovery, severely disabled or vegetative, and brain dead. Patients who had died of systemic complications (pneumonia, septicemia, renal failure, etc.) were excluded from the study. The Glasgow Coma Score was reliable in forecasting a favorable outcome; all patients with a Score over 9 points had a good recovery. The Glasgow Coma Score was not reliable in predicting an unfavorable outcome, however; some patients with the lowest possible Glasgow Coma Score (3 points) at the early clinical examination survived with good recovery. The BAEPs were reliable predictors of an unfavorable outcome; the outcome was unfavorable when a missing wave V or more missing waves pointed toward a secondary brainstem lesion. Normal BAEPs were not reliable, however, in predicting a favorable outcome. SEP data served as a prognostic indicator of unfavorable as well as favorable outcomes. In summary, evoked potentials add valuable information to the clinical examination in assessing a patient's outcome after severe head injury.

  2. Properties of rectified averaging of an evoked-type signal: theory and application to the vestibular-evoked myogenic potential.

    Science.gov (United States)

    Colebatch, J G

    2009-11-01

    The properties of rectified averages were investigated using the VEMP (vestibular-evoked myogenic potential) as an example of an evoked-type response. Recordings were made of surface EMG from the sternocleidomastoid (SCM) muscles of six volunteers, unstimulated, at different levels of tonic activation and then in response to clicks of different intensities. The stochastic properties of the surface EMG recorded were shown to be well modelled using a zero mean normal distribution with a standard deviation equivalent to the mean RMS (root mean squared) value (mean residual error variance 0.87%). Assuming a normal distribution, equations were derived for the expected value of both the rectified and RMS average with the addition of constant waveforms of different sizes. A simulation using recorded EMG and added sine waves of different amplitudes demonstrated that the equations predicted the rectified averages accurately. It also confirmed the importance of the relative amplitude of the added signal in determining whether it was detected using rectified averages. The same equations were then applied to actual data consisting of VEMPs of different relative amplitudes recorded from the volunteers. Whilst the signal-to-noise ratio (measured by corrected amplitude) was a major determinant of the nature of the rectified average, consistent deviations were detected between the predicted and actual rectified averages. Deviations from predicted values indicated that the VEMP did not behave simply like a constant signal added to tonic background EMG. A more complicated model, which included temporal jitter as well as inhibition of background EMG during the VEMP, was required to fit the physiological recordings. Rectified averages are sensitive to physiological properties, which are not apparent when using unrectified averages alone. Awareness of the properties of rectified averages should improve their interpretation.

  3. [Visual evoked responses with flash pattern in normal subjects (author's transl)].

    Science.gov (United States)

    Samson-Dollfus, D; Parain, D; Mihout, B; Menard, J F; Weber, J; Neheli, F

    1981-11-01

    Visual evoked responses to flash pattern simulations have been observed in young healthy adults. Stimulations of whole visual fields (37 subjects) and half-fields (11 subjects) have been performed. These responses are reproductible from one subject to another and show very clear waves in the occipital and central regions. On central leads, whatever the stimulation (stimulation of total visual fields or half-fields), the responses are always the same: a negative peak at 70 msec. followed by a positive peak at 90 msec, then a negative peak at 116-120 msec. On occipital leads, stimulation of the whole visual field shows a diphasic response: a positive wave at 100 msec and a negative wave at 140-150 msec. However, half-field stimulation shows different responses on the ipsi- and contralateral hemispheres, with a disappearance of the positive 100 msec wave in the ipsilateral occipital region. Thus, flash pattern stimulations seem to be useful in clinical practice because they evoke different types of responses in occipital and central regions.

  4. Early Stage of Pulsed Discharge in Water

    Institute of Scientific and Technical Information of China (English)

    卢新培; 潘垣; 刘克富; 刘明海; 张寒虹

    2001-01-01

    The bubble radius at the early stage of discharge in water is investigated using high-speed photography. Some simulation results on the bubble radius are presented, which are in agreement with the experimental results, with a maximum difference of about 10%. The reasons why the peak pressure of the first shock wave is only related to the energy released in the bubble during the first half period are addressed. The energy released in the bubble after the first half period increases the bubble pulsation period, but it produces no more than 10% under the peak pressure of the second shock wave.

  5. Changes of evoked potential in different hippocampal regions induced by electrostimulation at medial mamillary nucleus of rats

    Institute of Scientific and Technical Information of China (English)

    Xinxin Li; Lihong Shang; Liang Zhang; Fengzhi Cui

    2006-01-01

    BACKGROUND: Morphological data have shown that the most important afferent fibers of papillary body come from hippocampal structure.OBJECTIVE: To observe the changes of evoked potential in hippocampus and the significance after electrostimulation at medial mamillary nucleus.DESIGN: An observational control experiment.SETTING: Department of Physiology, Shenyang Medical College.MATERIALS: Twenty-three male or female Wistar rats, 3-4 months old, weighing 270-350 g, were provided by bhe animal room of Shenyang Medical College [the license number was scxk(Liao)2003-0016].METHODS: The Wistar rats were anaesthetized by intraperintoneal injection of 20% urethane (1 g/kg), tracheal intubation was also given. The self-made double-pole metal stimulating electrode with the point diameter of 1 mm was inserted into medial mamillary nucleus, the wanted hippocampal guidance spot was found within the rang of the hippocampal region at the same side of tee mamillary body range (CA1-CA4),inserted with same-core guidance electrode, a sole square-wave stimulation of wave wide 0.2 ms stimulated with electrodes at the applied intensity of 7-9 V, the evoked potential was induced through guidance electrodes, and then input to the ATAC-350 data-processing machine for memory showing wave processing, the memory recorded wave recording graph was separately drawn up by the X-Y recording instrument to observe the latency, time procedure and amplitude of the evoked potential in each hippocampal region of the rats and calculate the percentage of the evoked potential in each hippocampal region, Totally 78 guidance spots in hippocampus were recorded, including 30 positive reaction spots and 48 negative ones.MAIN OUTCOME MEASURES:① Latency,time procedure and amplitude of the evoked potentials in each hippocampal region of rats;② percentage of the evoked potentials in each hippocampal region;③ the wave shapes of the evoked potentials in each hippocampal region from different arrangement in the

  6. The Analysis of Disparity Evoked Potentials by a New Form of Static Random—Dot Stereograms

    Institute of Scientific and Technical Information of China (English)

    ChuanHou; XuexinZhang

    1995-01-01

    Purpose:A new form of static random-dot stereograms free of monoular clues was designed as stimulus to elicit disparity evoked potentials.Methods:Disparity evoked potentials were recorded in 40stereo-normal subjects.The stimulator was a white-black static random-dot stereograms generated by a computer and had no monocular clues.Every subject was tested in disparity stim-ulus,zero disparity stimulus,monocuular stimulus and wearing prism condition.Results:A characteristic wide positive wave at about 250ms was consistantly recorded in disparity stimulus,which amy be regarded as evidence of the the pres-ence of stereopsis .In contrast,recordings for zero disparity stimulus,monocular vision,stimulus and wearing prism condition all demonstrated a markedly differ-ence from recording for disparity stimulus.

  7. V ISUAL EVOKED POTENTIALS IN TYPE - 1 DIABETES WITHOUT RETINOPATHY: CO - RELATIONS WITH DURATION OF DIABETES

    Directory of Open Access Journals (Sweden)

    Sanjeev Kumar

    2014-01-01

    Full Text Available 20 diabetic (Type 1 patients have been studied in order to investigate the possible effects of the type 1 diabetes mellitus on the central nervous system by means of pattern shift visual evoked potentials. Patients with diabetic retinopathy , glaucoma and cataract were excluded from the study. To evaluate central optic pathways involvement in diabetics , visual evoked po tentials (VEP , in particular the latency of positive peak (P100 , were studied in 20 patients and 20 normal controls using reversal pattern VEP. P100 latency was significantly increased in diabetics. A positive co - relation was also found between latencies of VEP and duration of disease. Relationship between blood sugar level and P 100 wave latencies and amplitudes in diabetic patients was not significant . VEP measurement seems a simple and sensitive method for detecting early involvement and changes in opti c pathways in diabetics

  8. Filament Discharge Phenomena in Fingerprint Acquisition by Dielectric Barrier Discharge

    Institute of Scientific and Technical Information of China (English)

    WENG Ming; XU Weijun; LIU Qiang

    2007-01-01

    In this paper, the dielectric barrier discharge fingerprint acquisition technique is introduced. The filament discharge phenomena were observed in the process of fingerprint acquisition. The filament discharge reduced the quality of fingerprint images. Obviously, it was necessary to eliminate streamer discharges in order to get good fingerprint images. The streamer discharge was considered to be the cause of the filament discharge in the experiment. The relationship between the critical electric field and the discharge gap was calculated with the Raether's model of streamer discharge. The calculated results and our experiment proved that it would be difficult for the streamer discharge to occur when the discharge gap was narrow. With a narrow discharge gap, the discharge was homogeneous, and the fingerprint images were clear and large in area. The images obtained in the experiment are very suitable for fingerprint identification as they contain more information.

  9. Ultrasonic partial discharge monitoring method on instrument transformers

    Directory of Open Access Journals (Sweden)

    Kartalović Nenad

    2012-01-01

    Full Text Available Sonic and ultrasonic partial discharge monitoring have been applied since the early days of these phenomena monitoring. Modern measurement and partial discharge acoustic (ultrasonic and sonic monitoring method has been rapidly evolving as a result of new electronic component design, information technology and updated software solutions as well as the development of knowledge in the partial discharge diagnosis. Electrical discharges in the insulation system generate voltage-current pulses in the network and ultrasonic waves that propagate through the insulation system and structure. Amplitude-phase-frequency analysis of these signals reveals information about the intensity, type and location of partial discharges. The paper discusses the possibility of ultrasonic method selectivity improvement and the increase of diagnosis reliability in the field. Measurements were performed in the laboratory and in the field while a number of transformers were analysed for dissolved gases in the oil. A comparative review of methods for the partial discharge detection is also presented in this paper.

  10. Microtearing modes in tokamak discharges

    Energy Technology Data Exchange (ETDEWEB)

    Rafiq, T.; Kritz, A. H. [Department of Physics, Lehigh University, Bethlehem, Pennsylvania 18015 (United States); Weiland, J. [Department of Applied Physics, Chalmers University, S41296 Gothenburg (Sweden); Luo, L. [IBM Research, Oak Ridge, Tennessee 37831 (United States); Pankin, A. Y. [Tech-X Corporation, Boulder, Colorado 80308 (United States)

    2016-06-15

    Microtearing modes (MTMs) have been identified as a source of significant electron thermal transport in tokamak discharges. In order to describe the evolution of these discharges, it is necessary to improve the prediction of electron thermal transport. This can be accomplished by utilizing a model for transport driven by MTMs in whole device predictive modeling codes. The objective of this paper is to develop the dispersion relation that governs the MTM driven transport. A unified fluid/kinetic approach is used in the development of a nonlinear dispersion relation for MTMs. The derivation includes the effects of electrostatic and magnetic fluctuations, arbitrary electron-ion collisionality, electron temperature and density gradients, magnetic curvature, and the effects associated with the parallel propagation vector. An iterative nonlinear approach is used to calculate the distribution function employed in obtaining the nonlinear parallel current and the nonlinear dispersion relation. The third order nonlinear effects in magnetic fluctuations are included, and the influence of third order effects on a multi-wave system is considered. An envelope equation for the nonlinear microtearing modes in the collision dominant limit is introduced in order to obtain the saturation level. In the limit that the mode amplitude does not vary along the field line, slab geometry, and strong collisionality, the fluid dispersion relation for nonlinear microtearing modes is found to agree with the kinetic dispersion relation.

  11. Microtearing modes in tokamak discharges

    Science.gov (United States)

    Rafiq, T.; Weiland, J.; Kritz, A. H.; Luo, L.; Pankin, A. Y.

    2016-06-01

    Microtearing modes (MTMs) have been identified as a source of significant electron thermal transport in tokamak discharges. In order to describe the evolution of these discharges, it is necessary to improve the prediction of electron thermal transport. This can be accomplished by utilizing a model for transport driven by MTMs in whole device predictive modeling codes. The objective of this paper is to develop the dispersion relation that governs the MTM driven transport. A unified fluid/kinetic approach is used in the development of a nonlinear dispersion relation for MTMs. The derivation includes the effects of electrostatic and magnetic fluctuations, arbitrary electron-ion collisionality, electron temperature and density gradients, magnetic curvature, and the effects associated with the parallel propagation vector. An iterative nonlinear approach is used to calculate the distribution function employed in obtaining the nonlinear parallel current and the nonlinear dispersion relation. The third order nonlinear effects in magnetic fluctuations are included, and the influence of third order effects on a multi-wave system is considered. An envelope equation for the nonlinear microtearing modes in the collision dominant limit is introduced in order to obtain the saturation level. In the limit that the mode amplitude does not vary along the field line, slab geometry, and strong collisionality, the fluid dispersion relation for nonlinear microtearing modes is found to agree with the kinetic dispersion relation.

  12. Abdominal radiation - discharge

    Science.gov (United States)

    Radiation - abdomen - discharge; Cancer - abdominal radiation; Lymphoma - abdominal radiation ... When you have radiation treatment for cancer, your body goes through changes. About 2 weeks after radiation treatment starts, you might notice changes ...

  13. Chest radiation - discharge

    Science.gov (United States)

    Radiation - chest - discharge; Cancer - chest radiation; Lymphoma - chest radiation ... When you have radiation treatment for cancer, your body goes through changes. About 2 weeks after your first treatment: It may be hard ...

  14. Breast radiation - discharge

    Science.gov (United States)

    Radiation - breast - discharge ... away around 4 to 6 weeks after the radiation treatment is over. You may notice changes in ... breast looks or feels (if you are getting radiation after a lumpectomy). These changes include: Soreness or ...

  15. Corneal transplant - discharge

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000243.htm Corneal transplant - discharge To use the sharing features on this page, please enable JavaScript. You had a corneal transplant. Most of the tissue of your cornea (the ...

  16. Brain radiation - discharge

    Science.gov (United States)

    Radiation - brain - discharge; Cancer-brain radiation; Lymphoma - brain radiation; Leukemia - brain radiation ... Decadron) while you are getting radiation to the brain. It may make you hungrier, cause leg swelling ...

  17. Pneumonia - children - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000011.htm Pneumonia in children - discharge To use the sharing features ... this page, please enable JavaScript. Your child has pneumonia, which is an infection in the lungs. In ...

  18. Pneumonia - adults - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000017.htm Pneumonia in adults - discharge To use the sharing features on this page, please enable JavaScript. You have pneumonia, which is an infection in your lungs. In ...

  19. Inguinal hernia - discharge

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/patientinstructions/000274.htm Inguinal hernia repair - discharge To use the sharing features on ... your child had surgery to repair an inguinal hernia caused by a weakness in the abdominal wall ...

  20. Cosmetic breast surgery - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000273.htm Cosmetic breast surgery - discharge To use the sharing features on this page, please enable JavaScript. You had cosmetic breast surgery to change the size or shape ...

  1. Pectus excavatum - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000298.htm Pectus excavatum - discharge To use the sharing features on this ... You or your child had surgery to correct pectus excavatum. This is a deformity of the front of ...

  2. Hip fracture - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000168.htm Hip fracture - discharge To use the sharing features on this page, please enable JavaScript. Hip fracture surgery is done to repair a break in ...

  3. Capacitor discharge pulse analysis.

    Energy Technology Data Exchange (ETDEWEB)

    Baker, Michael Sean; Griffiths, Stewart K.; Tanner, Danelle Mary

    2013-08-01

    Capacitors used in firing sets and other high discharge current applications are discharge tested to verify performance of the capacitor against the application requirements. Parameters such as capacitance, inductance, rise time, pulse width, peak current and current reversal must be verified to ensure that the capacitor will meet the application needs. This report summarizes an analysis performed on the discharge current data to extract these parameters by fitting a second-order system model to the discharge data and using this fit to determine the resulting performance metrics. Details of the theory and implementation are presented. Using the best-fit second-order system model to extract these metrics results in less sensitivity to noise in the measured data and allows for direct extraction of the total series resistance, inductance, and capacitance.

  4. Pelvic radiation - discharge

    Science.gov (United States)

    Radiation of the pelvis - discharge; Cancer treatment - pelvic radiation; Prostate cancer - pelvic radiation; Ovarian cancer - pelvic radiation; Cervical cancer - pelvic radiation; Uterine cancer - pelvic radiation; Rectal cancer - pelvic radiation

  5. GABAA receptors modulate cannabinoid-evoked hypothermia.

    Science.gov (United States)

    Rawls, S M; Tallarida, R J; Kon, D A; Geller, E B; Adler, Martin W

    2004-05-01

    Cannabinoids evoke hypothermia by stimulating central CB(1) receptors. GABA induces hypothermia via GABA(A) or GABA(B) receptor activation. CB(1) receptor activation increases GABA release in the hypothalamus, a central locus for thermoregulation, suggesting that cannabinoid and GABA systems may be functionally linked in body temperature regulation. We investigated whether GABA receptors modulate the hypothermic actions of [4,5-dihydro-2-methyl-4(4-morpholinylmethyl)-1-(1-naphthalenyl-carbonyl)-6H-pyrrolo[3,2,1ij]quinolin-6-one] (WIN 55212-2), a selective cannabinoid agonist, in male Sprague-Dawley rats. WIN 55212-2 (2.5 mg/kg im) produced a rapid hypothermia that peaked 45-90 min postinjection. The hypothermia was attenuated by bicuculline (2 mg/kg ip), a GABA(A) antagonist. However, SCH 50911 (1-10 mg/kg ip), a GABA(B) blocker, did not antagonize the hypothermia. Neither bicuculline (2 mg/kg) nor SCH 50911 (10 mg/kg) by itself altered body temperature. We also investigated a possible role for CB(1) receptors in GABA-generated hypothermia. Muscimol (2.5 mg/kg ip), a GABA(A) agonist, or baclofen (5 mg/kg ip), a GABA(B) agonist, evoked a significant hypothermia. Blockade of CB(1) receptors with SR141716A (2.5 mg/kg im) did not antagonize muscimol- or baclofen-induced hypothermia, indicating that GABA-evoked hypothermia does not contain a CB(1)-sensitive component. Our results implicate GABA(A) receptors in the hypothermic actions of cannabinoids and provide further evidence of a functional link between cannabinoid and GABA systems.

  6. Do ambient urban odors evoke basic emotions?

    Science.gov (United States)

    Glass, Sandra T; Lingg, Elisabeth; Heuberger, Eva

    2014-01-01

    Fragrances, such as plant odors, have been shown to evoke autonomic response patterns associated with Ekman's (Ekman et al., 1983) basic emotions happiness, surprise, anger, fear, sadness, and disgust. Inducing positive emotions by odors in highly frequented public spaces could serve to improve the quality of life in urban environments. Thus, the present study evaluated the potency of ambient odors connoted with an urban environment to evoke basic emotions on an autonomic and cognitive response level. Synthetic mixtures representing the odors of disinfectant, candles/bees wax, summer air, burnt smell, vomit and musty smell as well as odorless water as a control were presented five times in random order to 30 healthy, non-smoking human subjects with intact sense of smell. Skin temperature, skin conductance, breathing rate, forearm muscle activity, blink rate, and heart rate were recorded simultaneously. Subjects rated the odors in terms of pleasantness, intensity and familiarity and gave verbal labels to each odor as well as cognitive associations with the basic emotions. The results showed that the amplitude of the skin conductance response (SCR) varied as a function of odor presentation. Burnt smell and vomit elicited significantly higher electrodermal responses than summer air. Also, a negative correlation was revealed between the amplitude of the SCR and hedonic odor valence indicating that the magnitude of the electrodermal response increased with odor unpleasantness. The analysis of the cognitive associations between odors and basic emotions showed that candles/bees wax and summer air were specifically associated with happiness whereas burnt smell and vomit were uniquely associated with disgust. Our findings suggest that city odors may evoke specific cognitive associations of basic emotions and that autonomic activity elicited by such odors is related to odor hedonics.

  7. Do ambient urban odors evoke basic emotions?

    Directory of Open Access Journals (Sweden)

    Sandra Theresia Weber-Glass

    2014-04-01

    Full Text Available Fragrances, such as plant odors, have been shown to evoke autonomic response patterns associated with Ekman’s (Ekman et al., 1983 basic emotions happiness, surprise, anger, fear, sadness and disgust. Inducing positive emotions by odors in highly frequented public spaces could serve to improve the quality of life in urban environments. Thus, the present study evaluated the potency of ambient odors connoted with an urban environment to evoke basic emotions on an autonomic and cognitive response level. Synthetic mixtures representing the odors of disinfectant, candles / bees wax, summer air, burnt smell, vomit and musty smell as well as odorless water as a control were presented five times in random order to 30 healthy, non-smoking human subjects with intact sense of smell. Skin temperature, skin conductance, breathing rate, forearm muscle activity, blink rate and heart rate were recorded simultaneously. Subjects rated the odors in terms of pleasantness, intensity and familiarity and gave verbal labels to each odor as well as cognitive associations with the basic emotions. The results showed that the amplitude of the skin conductance response varied as a function of odor presentation. Burnt smell and vomit elicited significantly higher electrodermal responses than summer air. Also, a negative correlation was revealed between the amplitude of the skin conductance response and hedonic odor valence indicating that the magnitude of the electrodermal response increased with odor unpleasantness. The analysis of the cognitive associations between odors and basic emotions showed that candles / bees wax and summer air were specifically associated with happiness whereas burnt smell and vomit were uniquely associated with disgust. Our findings suggest that city odors may evoke specific cognitive associations of basic emotions and that autonomic activity elicited by such odors is related to odor hedonics.

  8. Somatosensory evoked response: application in neurology

    Directory of Open Access Journals (Sweden)

    Carlos A. M. Guerreiro

    1982-03-01

    Full Text Available One technique used for short-latency somatosensory evoked response (SER is described. SER following nerve stimulation is a unique non-invasive, clinical test used to evaluate the somatosensory pathways. It tests the physiological function of the median nerve, the brachial plexus, the C6-7 cervical roots, cervical spinal cord, the cuneate nuclei, the medial lemniscus, the thalamus, and the contralateral sensory cortex. It has been shown to be a reliable and useful clinical test partiicularly in multiple sclerosis and comatose patients. The promising technique of SER following peroneal nerve stimulation is mentioned.

  9. Experimental study on mean overtopping of sloping seawall under oblique irregular waves

    Science.gov (United States)

    Wang, Deng-ting; Ju, Lie-hong; Zhu, Jia-ling; Wang, Zhen; Sun, Tian-ting; Chen, Wei-qiu

    2017-06-01

    In this paper, domestic and abroad research progresses and related calculation formulae of the mean overtopping discharge are summarized. Through integral physical model experiments, the relation between the wave direction and the overtopping discharge on the top of the sloping dike is focused on and put into analysis and discussion; and a modified formula for mean overtopping discharges under oblique irregular waves is proposed. The study shows that the mean overtopping discharge generally goes down as the relative wave obliquity β increases for a fixed measurement point and the mean overtopping discharge generally increases as the wave steepness H/L decreases (the cycle increases) for a fixed relative wave obliquity.

  10. Identifying discharge practice training needs.

    Science.gov (United States)

    Lees, L; Emmerson, K

    A training needs analysis tool was developed to identify nurses' discharge training needs and to improve discharge practice. The tool includes 49 elements of discharge practice subdivided into four areas: corporate, operational, clinical and nurse-led discharge. The tool was disseminated to 15 wards on two hospital sites with assistance from the practice development team. Analysis of discharge training is important to assess discharge training needs and to identify staff who may assist with training.

  11. Development of Partial Discharge Sensing Device for Epoxy Resin Bushing

    Science.gov (United States)

    Mutakamihigashi, Tatsuya; Kawasaki, Makoto; Hashiba, Yasuhito

    For the electric power equipment and the cables, prevention of accident is very important. And in substations, a lot of solid insulations using epoxy resin are introduced into cubicle-type switchgears because of its high insulation reliability and down-sizing ability. We know a phenomenon that partial discharge occur when electric installation have degraded. When void or crack exist in the polymer insulating materials or interface of conductor, partial discharge is caused and finally results in breakdown. In recent years, the feature is seen in the partial discharge generated in the epoxy resin before and after the progress of electric tree by our research. Electro-magnetic wave spectra radiated from partial discharge have specific frequency region from 200MHz to 450MHz. We developed the sensing device that can detect the electric discharge by receiving the signal by mobile antenna. We proved the performance of this equipment in operating substations; As a result, partial discharge in epoxy resin was detected by electro-magnetic wave. And then, we removed epoxy resin bushing from the cubicle and measured partial discharge by discharging current, we confirmed that presumed level is correct.

  12. Pattern reversal visual evoked potentials in migraine subjects without aura

    Directory of Open Access Journals (Sweden)

    Pedro F. Moreira Filho

    1994-12-01

    Full Text Available Twenty seven patients with migraine without aura were investigated. The age was between 12 and 54 years; 5 were men and 22 women. The diagnosis of migraine was made according to the classification proposed by the International Headache Society. The method of visual evoked potential was performed with pattern reversal (VEP-PR, with monocular stimulation. The stimulation was performed with pattern reversal with 4x4 cm black and white and red and green squared screen placed 1 meter from the nasion at stimulus frequency 1/s; 128 individual trials were analysed. The VEP-PR with black/white and red/green study showed a significant increase of value of the P-100 latency in 10 migraine patients. In 8 cases the LP100 in VEP-PR black/white was normal but in VEP-PR red/green the LP100 showed increase. Specifically in 1 of our cases, LP100 were normal in VEP-PR black/white but in the red/green there were no reproductice waves. On basis of these observations we consider that the method of VEP-PR is an useful instrument for investigation of migraine patients without aura.

  13. Visual Evoked Potentials in Patients with Classic Migraine

    Directory of Open Access Journals (Sweden)

    Akbar Hamzei-Moghaddam

    2013-04-01

    Full Text Available Background: Migraine is considered as a chronic disease. Ocular symptoms and sensitivity to light stimuli are common in the patients with such disease. There are some evident that visual system function in the patients with migraine is impaired even between the attacks as compared with health people. In this study, we examine Visual Evoked Potential in 30 patients suffered from migraine before, during and after aura. Materials and Methods: 30 patients suffered from classic migraine and with visual aura were evaluated in terms of visual stimulatory potentials before, during and after aura. P-100 latency and amplitude were evaluation criteria in our study. The results of this investigation were evaluated by χ2 test.Results: Abnormal amplitude frequency was occurred in 17 cases before aura, in 27 cases during aura and in 20 cases, it occurred after aura. Reduction of the amplitude wave p-100 during and after aura was significantly more in both eyes (p<0.05. Ten cases had abnormal P-100 latency during aura and the other two cases had it after aura. There is a significant difference in the P-100 latency during aura (p<0.05. There is no difference between the changes in visual stimulatory potentials with gender.Conclusion: Some changes were found in the parameters in the visual stimulatory potentials in the patients with classic migraine before, during and after aura.

  14. Flash visual evoked potentials in diurnal birds of prey

    Directory of Open Access Journals (Sweden)

    Maurizio Dondi

    2016-07-01

    Full Text Available The objective of this pilot study was to evaluate the feasibility of Flash Visual Evoked Potentials (FVEPs testing in birds of prey in a clinical setting and to describe the protocol and the baseline data for normal vision in this species. FVEP recordings were obtained from 6 normal adult birds of prey: n. 2 Harris’s Hawks (Parabuteo unicinctus, n. 1 Lanner Falcon (Falco biarmicus, n. 2 Gyrfalcons (Falco rusticolus and n. 1 Saker Falcon (Falco cherrug. Before carrying out VEP tests, all animals underwent neurologic and ophthalmic routine examination. Waveforms were analysed to identify reproducible peaks from random variation of baseline. At least three positive and negative peaks were highlighted in all tracks with elevated repeatability. Measurements consisted of the absolute and relative latencies of these peaks (P1, N1, P2, N2, P3, and N3 and their peak-to-peak amplitudes. Both the peak latency and wave morphology achieved from normal animals were similar to those obtained previously in other animal species. This test can be easily and safely performed in a clinical setting in birds of prey and could be useful for an objective assessment of visual function.

  15. Brainstem auditory-evoked potential in Boxer dogs

    Directory of Open Access Journals (Sweden)

    Mariana Isa Poci Palumbo

    2014-10-01

    Full Text Available Brainstem auditory-evoked potential (BAEP has been widely used for different purposes in veterinary practice and is commonly used to identify inherited deafness and presbycusis. In this study, 43 Boxer dogs were evaluated using the BAEP. Deafness was diagnosed in 3 dogs (2 bilateral and 1 unilateral allowing the remaining 40 Boxers to be included for normative data analysis including an evaluation on the influence of age on the BAEP. The animals were divided into 2 groups of 20 Boxers each based on age. The mean age was 4.54 years (range, 1-8 in group I, and 9.83 years (range, 8.5-12 in group II. The mean latency for I, III, and V waves were 1.14 (±0.07, 2.64 (±0.11, and 3.48 (±0.10 ms in group I, and 1.20 (±0.12, 2.73 (±0.15, and 3.58 (±0.22 ms in group II, respectively. The mean inter-peak latencies for the I-III, III-V and I-V intervals were 1.50 (±0.15, 0.84 (±0.15, and 2.34 (±0.11 ms in group I, and 1.53 (±0.16, 0.85 (±0.15, and 2.38 (±0.19 ms in group II, respectively. Latencies of waves I and III were significant different between group I and II. For the I-III, III-V and I-V intervals, no significant differences were observed between the 2 groups. As far as we know, this is the first normative study of BAEP obtained from Boxer dogs.

  16. Evoked potentials in pediatric cerebral malaria

    Directory of Open Access Journals (Sweden)

    Minal Bhanushali

    2011-12-01

    Full Text Available Cortical evoked potentials (EP provide localized data regarding brain function and may offer prognostic information and insights into the pathologic mechanisms of malariamediated cerebral injury. As part of a prospective cohort study, we obtained somatosensory evoked potentials (SSEPs and brainstem auditory EPs (AEPs within 24 hours of admission on 27 consecutive children admitted with cerebral malaria (CM. Children underwent follow-up for 12 months to determine if they had any long term neurologic sequelae. EPs were obtained in 27 pediatric CM admissions. Two children died. Among survivors followed an average of 514 days, 7/25 (28.0% had at least one adverse neurologic outcome. Only a single subject had absent cortical EPs on admission and this child had a good neurologic outcome. Among pediatric CM survivors, cortical EPs are generally intact and do not predict adverse neurologic outcomes. Further study is needed to determine if alterations in cortical EPs can be used to predict a fatal outcome in CM.

  17. Long Latency Auditory Evoked Potentials during Meditation.

    Science.gov (United States)

    Telles, Shirley; Deepeshwar, Singh; Naveen, Kalkuni Visweswaraiah; Pailoor, Subramanya

    2015-10-01

    The auditory sensory pathway has been studied in meditators, using midlatency and short latency auditory evoked potentials. The present study evaluated long latency auditory evoked potentials (LLAEPs) during meditation. Sixty male participants, aged between 18 and 31 years (group mean±SD, 20.5±3.8 years), were assessed in 4 mental states based on descriptions in the traditional texts. They were (a) random thinking, (b) nonmeditative focusing, (c) meditative focusing, and (d) meditation. The order of the sessions was randomly assigned. The LLAEP components studied were P1 (40-60 ms), N1 (75-115 ms), P2 (120-180 ms), and N2 (180-280 ms). For each component, the peak amplitude and peak latency were measured from the prestimulus baseline. There was significant decrease in the peak latency of the P2 component during and after meditation (Pmeditation facilitates the processing of information in the auditory association cortex, whereas the number of neurons recruited was smaller in random thinking and non-meditative focused thinking, at the level of the secondary auditory cortex, auditory association cortex and anterior cingulate cortex.

  18. New perspectives on vestibular evoked myogenic potentials.

    Science.gov (United States)

    Rosengren, Sally M; Kingma, Herman

    2013-02-01

    Although the vestibular evoked myogenic potential (VEMP) measured from the cervical muscles (cVEMP, cervical VEMP) is well described and has documented clinical utility, its analogue recorded from the extraocular muscles (oVEMP, ocular VEMP) has been described only recently and is currently emerging as an additional test of otolith function. This review will, therefore, summarize recent developments in VEMP research with a focus on the oVEMP. Recent studies suggest that the oVEMP is produced by otolith afferents in the superior vestibular nerve division, whereas the cVEMP evoked by sound is thought to be an inferior vestibular nerve reflex. Correspondingly, the oVEMP correlates better with caloric and subjective visual vertical tests than sound-cVEMPs. cVEMPs are more complicated than often thought, as shown by the presence of crossed responses and conflicting results of recent vibration studies. Altered inner ear mechanics produced by the vestibular diseases superior semicircular canal dehiscence and Ménière's disease lead to changes in the preferred frequency of the oVEMP and cVEMP. The oVEMP provides complementary diagnostic information to the cVEMP and is likely to be a useful addition to the diagnostic test battery in neuro-otology.

  19. Speech Evoked Auditory Brainstem Response in Stuttering

    Directory of Open Access Journals (Sweden)

    Ali Akbar Tahaei

    2014-01-01

    Full Text Available Auditory processing deficits have been hypothesized as an underlying mechanism for stuttering. Previous studies have demonstrated abnormal responses in subjects with persistent developmental stuttering (PDS at the higher level of the central auditory system using speech stimuli. Recently, the potential usefulness of speech evoked auditory brainstem responses in central auditory processing disorders has been emphasized. The current study used the speech evoked ABR to investigate the hypothesis that subjects with PDS have specific auditory perceptual dysfunction. Objectives. To determine whether brainstem responses to speech stimuli differ between PDS subjects and normal fluent speakers. Methods. Twenty-five subjects with PDS participated in this study. The speech-ABRs were elicited by the 5-formant synthesized syllable/da/, with duration of 40 ms. Results. There were significant group differences for the onset and offset transient peaks. Subjects with PDS had longer latencies for the onset and offset peaks relative to the control group. Conclusions. Subjects with PDS showed a deficient neural timing in the early stages of the auditory pathway consistent with temporal processing deficits and their abnormal timing may underlie to their disfluency.

  20. Auditory evoked potentials in postconcussive syndrome.

    Science.gov (United States)

    Drake, M E; Weate, S J; Newell, S A

    1996-12-01

    The neuropsychiatric sequelae of minor head trauma have been the source of controversy. Most clinical and imaging studies have shown no alteration after concussion, but neuropsychological and neuropathological abnormalities have been reported. Some changes in neurophysiologic diagnostic tests have been described in postconcussive syndrome. We recorded middle latency auditory evoked potentials (MLR) and slow vertex responses (SVR) in 20 individuals with prolonged cognitive difficulties, behavior changes, dizziness, and headache after concussion. MLR is utilized alternating polarity clicks presented monaurally at 70 dB SL at 4 per second, with 40 dB contralateral masking. Five hundred responses were recorded and replicated from Cz-A1 and Cz-A2, with 50 ms. analysis time and 20-1000 Hz filter band pass. SVRs were recorded with the same montage, but used rarefaction clicks, 0.5 Hz stimulus rate, 500 ms. analysis time, and 1-50 Hz filter band pass. Na and Pa MLR components were reduced in amplitude in postconcussion patients. Pa latency was significantly longer in patients than in controls. SVR amplitudes were longer in concussed individuals, but differences in latency and amplitude were not significant. These changes may reflect posttraumatic disturbance in presumed subcortical MLR generators, or in frontal or temporal cortical structures that modulate them. Middle and long-latency auditory evoked potentials may be helpful in the evaluation of postconcussive neuropsychiatric symptoms.

  1. Interaural difference values of vestibular evoked myogenic.

    Directory of Open Access Journals (Sweden)

    Marziyeh Moallemi

    2015-01-01

    Full Text Available Migraine is a neurologic disease, which often is associated with a unilateral headache. Vestibular abnormalities are common in migraine. Vestibular evoked myogenic potentials (VEMPs assess otolith function in particular functional integrity of the saccule and the inferior vestibular nerve. We used VEMP to evaluate if the migraine headache can affect VEMP asymmetry parameters. A total of 25 patients with migraine (22 females and 3 males who were diagnosed according to the criteria of IHS-1988 were enrolled in this cross-sectional study. Control group consisted of 26 healthy participants (18 female and 8 male, without neurotological symptoms and history of migraine. The short tone burst (95 dB nHL, 500 Hz was presented to ears. VEMP was recorded with surface electromyography over the contracted ipsilateral sternocleidomastoid (SCM muscle. Although current results showed that the amplitude ratio is greater in migraine patients than normal group, there was no statistical difference between two groups in mean asymmetry parameters of VEMP. Asymmetry measurements in vestibular evoked myogenic potentials probably are not indicators of unilateral deficient in saccular pathways of migraine patients.

  2. Acute effects of passive stretching on the electromechanical delay and evoked twitch properties.

    Science.gov (United States)

    Costa, Pablo B; Ryan, Eric D; Herda, Trent J; Walter, Ashley A; Hoge, Katherine M; Cramer, Joel T

    2010-01-01

    The purpose of this study was to investigate the acute effects of passive stretching on the electromechanical delay (EMD), peak twitch force (PTF), rate of force development (RFD), and compound muscle action potential (M-wave) amplitude during evoked twitches of the plantar flexor muscles. 16 men (mean age +/- SD = 21.1 +/- 1.7 years; body mass = 75.9 +/- 11.4 kg; height = 176.5 +/- 8.6 cm) participated in this study. A single, square-wave, supramaximal transcutaneous electrical stimulus was delivered to the tibial nerve before and after passive stretching. The stretching protocol consisted of nine repetitions of passive assisted stretching designed to stretch the calf muscles. Each repetition was held for 135 s separated by 5-10 s of rest. Dependent-samples t tests (pre- vs. post-stretching) were used to analyze the EMD, PTF, RFD, and M-wave amplitude data. There were significant changes (P 0.05). These findings suggested that passively stretching the calf muscles affected the mechanical aspects of force production from the onset of the electrically evoked twitch to the peak twitch force. These results may help to explain the mechanisms underlying the stretching-induced force deficit that have been reported as either "mechanical" or "electrical" in origin.

  3. Changes of evoked potential and expression of nestin in subventricular zones in rats after focal cerebral ischemia

    Institute of Scientific and Technical Information of China (English)

    GAO Jie; WANG Yong-tang; WANG Li-li; ZENG Ling; WU Ya-min; SHAO Yang

    2007-01-01

    Objective:To study the characteristics of latency of somatosensory evoked potential (SEP)and motor evoked potential (MEP) and the expression of nestin in subventricular zones (SVZ) after persistent focal cerebral ischemia in rats. Methods: The model of cerebral ischemia in rats was made by middle cerebral artery occlusion (MCAO). All animals of ischemia were sacrificed after 12 h, 1 d, 3 d, 7 d,and 14 d to observe the changes of latency of SEP and MEP and to detect the expression of nestin, with an immunohistochemical approach. Results: The latencies of P1 (positive wave 1), N1 (negative wave 1) and P2 (positive wave 2) in SEP were significantly prolonged after MCAO. The latencies of N1 and N2 waves in MEP were postponed gradually and no statistical difference of latency of N1 wave was found in rats at 7d and 14 d after MCAO. The expression of nestin increased at 12 h, and showed a significant augmentation at 3 d and peaked at 7 d, then declined slightly at 14 d after MCAO. Conclusion: The cerebral ischemia prolonged the latency of EP waves and the expression of nestin was up-regulated and reached the peak at 7d, showing the ischemia induced the proliferation of nervous stem cells. The SEP and MEP may evaluate the proliferation in SVZ after brain ischemia.

  4. The strychnine-like action of curare and related compounds on the somatosensory evoked response of the rat cortex

    Science.gov (United States)

    Bhargava, V. K.; Meldrum, B. S.

    1969-01-01

    1. Drugs were applied to the cerebral cortex of rats anaesthetized with pentobarbitone and changes measured in the somatosensory primary evoked response. 2. Computer-derived averages of thirty-two consecutive responses yielded stable and consistent measurements of the potential changes comprising the evoked response, and comparable records from the opposite (non-drug treated) cortex provided an essential control for systemic actions of the drug. 3. The modifications produced by curare and strychnine were indistinguishable. The first positive wave (peak latency 7 msec) was unaltered; the second positive wave (peak latency 11·5 msec) was variably enhanced, and the first and second negative waves (peak latencies 16 and 40 msec) were replaced by a much larger negative wave (peak latency 22 msec). 4. The time of onset of the effect on the negative waves and the maximal amplitude attained by the abnormal negative wave were related to the log concentration of the drug used. Curare is approximately 10 times more potent than strychnine. 5. Toxiferine I, di-allylnortoxiferine and atropine also produced this effect but were less potent than strychnine. 6. Succinylcholine, dihydro-β-erythroidine and gallamine triethiodide did not produce this effect (in concentrations up to 10-3M). 7. The observations are consistent with an action of curare and strychnine on an intracortical cholinergic inhibitory system, but other possibilities including a “non-specific excitatory action” cannot be excluded. PMID:5824927

  5. Effect of Acupuncture on the Auditory Evoked Brain Stem Potential in Parkinson's Disease

    Institute of Scientific and Technical Information of China (English)

    王玲玲; 何崇; 刘跃光; 朱莉莉

    2002-01-01

    @@ Under the auditory evoked brain stem potential (ABP) examination, the latent period of V wave and the intermittent periods of III-V peak and I-V peak were significantly shortened in Parkinson's disease patients of the treatment group (N=29) after acupuncture treatment. The difference of cumulative scores in Webster's scale was also decreased in correlation analysis. The increase of dopamine in the brain and the excitability of the dopamine neurons may contribute to the therapeutic effects, in TCM terms, of subduing the pathogenic wind and tranquilizing the mind.

  6. Effect of acupuncture on the auditory evoked brain stem potential in Parkinson's disease.

    Science.gov (United States)

    Wang, Lingling; He, Chong; Liu, Yueguang; Zhu, Lili

    2002-03-01

    Under the auditory evoked brain stem potential (ABP) examination, the latent period of V wave and the intermittent periods of III-V peak and I-V peak were significantly shortened in Parkinson's disease patients of the treatment group (N = 29) after acupuncture treatment. The difference of cumulative scores in Webster's scale was also decreased in correlation analysis. The increase of dopamine in the brain and the excitability of the dopamine neurons may contribute to the therapeutic effects, in TCM terms, of subduing the pathogenic wind and tranquilizing the mind.

  7. Comparison of the pattern reversal visual evoked potential mediated by separate cone systems

    DEFF Research Database (Denmark)

    Johnsen, B; Frederiksen, J.L.; Larsson, H.B.

    1995-01-01

    With the purpose of recording responses mediated by the 3 cone systems visual evoked potentials (VEPs) were elicited by the reversal of monochromatic checkerboards superimposed upon strong monochromatic backgrounds (yellow, purple and blue-green). The sensitivity to light of various wave lengths...... were measured as the reciprocal of the intensity necessary to elicit a VEP amplitude of 3 microV. The spectral sensitivity curves based on this VEP amplitude criterion in the presence of blue-green, purple and yellow adaptation showed peak sensitivities in the red, the green and the blue part...

  8. Analysis of Saccular Function With Vestibular Evoked Myogenic Potential Test in Meniere's Disease.

    Science.gov (United States)

    Dabiri, Sasan; Yazdani, Nasrin; Esfahani, Mahdis; Tari, Niloufar; Adil, Susan; Mahvi, Zahra; Rezazadeh, Nima

    2017-02-01

    Meniere's disease is the disorder of inner ear characterized by vertigo, tinnitus and sensorineural hearing loss. The vestibular evoked myogenic potential (VEMP) test could be useful in the analysis of saccular function, and diagnosis of Meniere's disease. In this study, we've analyzed the saccular function, using VEMP test in different groups of Meniere's disease. Patients were categorized as possible, probable or definite Meniere's disease groups according to the guideline of American Academy of Otolaryngology-Head and Neck Surgery. The exclusion criteria were neuromuscular system diseases, diseases of central nervous system, inner ear disorders, conductive hearing loss, a history of ototoxic drug consumption, being a drug abuser and a positive history of inner ear surgery or manipulations. The VEMP test is the recording of positive and negative waves from sternocleidomastoid muscle that is made by an auditory click to the ear. From the total of 100 patients, the waves of VEMP test was seen in 59 patients which 19 patients had abnormal amplitude, and latency and 40 patients were with normally recorded waves. There was a significant relationship between the severity of hearing loss and a VEMP test without any recorded waves. Most of the cases with 'no wave recorded' VEMP test, were patients with severe hearing loss. However, there wasn't any relation between the pattern of hearing loss and 'no wave recorded' VEMP test. VEMP test could be a valuable diagnostic clue especially in patients with definite Meniere's disease.

  9. Vestibular Dysfunctions in Cochlear Implant Patients; A Vestibular Evoked Myogenic Potential Study

    Directory of Open Access Journals (Sweden)

    Masoud Motasaddi Zarandy

    2011-12-01

    Full Text Available Background and Aim: Vestibular evoked myogenic potential in response to click or short tone burst stimuli have been used as a clinical test for distinguish saccule and inferior vestibular nerve diseases. Different studies show that cochlear implant could have inverse effects on vestibular structures. We aimed to investigate vestibular evoked myogenic potential in unilateral cochlear implanted individuals in compare to normal individuals.Methods: Thirty-three unilateral cochlear implanted patients (mean age 19.96 years and 30 normal hearing individuals (mean age 24-27 years as control group were enrolled in this cross- sectional study. Absolute latencies and amplitudes of myogenic potential responses were measured and compared in both groups.Results: Myogenic potential recorded in both ears of all controls were normal. No response could be recorded in 16 patients (48.48% from both ears. In three patients, responses were recorded in both ears though the amplitude of waves was reduced in implanted ear. Unilateral response could be recorded in 14 patients only in their non-implanted ear.Conclusion: Vestibular evoked myogenic potential test is a useful tool for assessing saccular function in cochlear implant patients. Damages of osseous spiral lamina and basilar membrane after cochlear implantation could result in dysfunctions of vestibular organs specially saccule. It seems that saccule could be easily damaged after cochlear implantation. This would cause absence or reduced amplitudes in myogenic potential.

  10. Microwave Discharge Ion Sources

    CERN Document Server

    Celona, L

    2013-01-01

    This chapter describes the basic principles, design features and characteristics of microwave discharge ion sources. A suitable source for the production of intense beams for high-power accelerators must satisfy the requirements of high brightness, stability and reliability. The 2.45 GHz off-resonance microwave discharge sources are ideal devices to generate the required beams, as they produce multimilliampere beams of protons, deuterons and singly charged ions. A description of different technical designs will be given, analysing their performance, with particular attention being paid to the quality of the beam, especially in terms of its emittance.

  11. Emittance of short-pulsed high-current ion beams formed from the plasma of the electron cyclotron resonance discharge sustained by high-power millimeter-wave gyrotron radiation

    Science.gov (United States)

    Razin, S.; Zorin, V.; Izotov, I.; Sidorov, A.; Skalyga, V.

    2014-02-01

    We present experimental results on measuring the emittance of short-pulsed (≤100 μs) high-current (80-100 mA) ion beams of heavy gases (Nitrogen, Argon) formed from a dense plasma of an ECR source of multiply charged ions (MCI) with quasi-gas-dynamic mode of plasma confinement in a magnetic trap of simple mirror configuration. The discharge was created by a high-power (90 kW) pulsed radiation of a 37.5-GHz gyrotron. The normalized emittance of generated ion beams of 100 mA current was (1.2-1.3) π mm mrad (70% of ions in the beams). Comparing these results with those obtained using a cusp magnetic trap, it was concluded that the structure of the trap magnetic field lines does not exert a decisive influence on the emittance of ion beams in the gas-dynamic ECR source of MCI.

  12. Evaluation of brain stem auditory evoked potentials in stable patients with chronic obstructive pulmonary disease

    Directory of Open Access Journals (Sweden)

    Gupta Prem

    2008-01-01

    Full Text Available Though there are few studies addressing brainstem auditory evoked potentials (BAEP in patients with chronic obstructive pulmonary disease (COPD, subclinical BAEP abnormalities in stable COPD patients have not been studied. The present study aimed to evaluate the BAEP abnormalities in this study group. Materials and Methods : In the present study, 80 male subjects were included: COPD group comprised 40 smokers with stable COPD with no clinical neuropathy; 40 age-matched healthy volunteers served as the control group. Latencies of BAEP waves I, II, III, IV, and V, together with interpeak latencies (IPLs of I-III, I-V, and III-V, and amplitudes of waves I-Ia and V-Va were studied in both the groups to compare the BAEP abnormalities in COPD group; the latter were correlated with patient characteristics and Mini-Mental Status Examination Questionnaire (MMSEQ scores to seek any significant correlation. Results: Twenty-six (65% of the 40 COPD patients had BAEP abnormalities. We observed significantly prolonged latencies of waves I, III, V over left ear and waves III, IV, V over right ear; increased IPLs of I-V, III-V over left ear and of I-III, I-V, III-V over right side. Amplitudes of waves I-Ia and V-Va were decreased bilaterally. Over left ear, the latencies of wave I and III were significantly correlated with FEV 1 ; and amplitude of wave I-Ia, with smoking pack years. A weak positive correlation between amplitude of wave I-Ia and duration of illness; and a weak negative correlation between amplitude of wave V-Va and MMSEQ scores were seen over right side. Conclusions : We observed significant subclinical BAEP abnormalities on electrophysiological evaluation in studied stable COPD male patients having mild-to-moderate airflow obstruction.

  13. Music evokes vicarious emotions in listeners.

    Science.gov (United States)

    Kawakami, Ai; Furukawa, Kiyoshi; Okanoya, Kazuo

    2014-01-01

    Why do we listen to sad music? We seek to answer this question using a psychological approach. It is possible to distinguish perceived emotions from those that are experienced. Therefore, we hypothesized that, although sad music is perceived as sad, listeners actually feel (experience) pleasant emotions concurrent with sadness. This hypothesis was supported, which led us to question whether sadness in the context of art is truly an unpleasant emotion. While experiencing sadness may be unpleasant, it may also be somewhat pleasant when experienced in the context of art, for example, when listening to sad music. We consider musically evoked emotion vicarious, as we are not threatened when we experience it, in the way that we can be during the course of experiencing emotion in daily life. When we listen to sad music, we experience vicarious sadness. In this review, we propose two sides to sadness by suggesting vicarious emotion.

  14. Bayesian analysis of MEG visual evoked responses

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, D.M.; George, J.S.; Wood, C.C.

    1999-04-01

    The authors developed a method for analyzing neural electromagnetic data that allows probabilistic inferences to be drawn about regions of activation. The method involves the generation of a large number of possible solutions which both fir the data and prior expectations about the nature of probable solutions made explicit by a Bayesian formalism. In addition, they have introduced a model for the current distributions that produce MEG and (EEG) data that allows extended regions of activity, and can easily incorporate prior information such as anatomical constraints from MRI. To evaluate the feasibility and utility of the Bayesian approach with actual data, they analyzed MEG data from a visual evoked response experiment. They compared Bayesian analyses of MEG responses to visual stimuli in the left and right visual fields, in order to examine the sensitivity of the method to detect known features of human visual cortex organization. They also examined the changing pattern of cortical activation as a function of time.

  15. Resting Heart Rate and Auditory Evoked Potential

    Directory of Open Access Journals (Sweden)

    Simone Fiuza Regaçone

    2015-01-01

    Full Text Available The objective of this study was to evaluate the association between rest heart rate (HR and the components of the auditory evoked-related potentials (ERPs at rest in women. We investigated 21 healthy female university students between 18 and 24 years old. We performed complete audiological evaluation and measurement of heart rate for 10 minutes at rest (heart rate monitor Polar RS800CX and performed ERPs analysis (discrepancy in frequency and duration. There was a moderate negative correlation of the N1 and P3a with rest HR and a strong positive correlation of the P2 and N2 components with rest HR. Larger components of the ERP are associated with higher rest HR.

  16. STUDY OF VISUAL EVOKED POTENTIAL IN TERM, APPROPRIATE FOR GESTATIONAL AGE NEWBORNS IN A TERTIARY HEALTH CARE FACILITY OF KOLKATA

    Directory of Open Access Journals (Sweden)

    Koushik

    2016-02-01

    Full Text Available INTRODUCTION Evoked potentials are small magnitude electrical potentials that originate within neural tissues in response to a variety of stimuli which are depicted as a wave or a series of waves. Changes in the wave latencies and amplitudes have been shown to reflect disturbances in neuronal growth rates & myelination of the developing nervous system. Among the different evoked potentials, the Visual Evoked Potentials (VEP, have been shown to be a significantly accurate tool for assessing the degree of neurological handicap among survivors of perinatal asphyxia, especially in the full-term neonates. Thus, the development of a normative database of VEP parameters like wave latencies and amplitudes for term, appropriate-for-gestational age neonates in an Indian NICU set-up was the primary objective of our study as such data can be of great use for future clinical use. The study was a prospective observational study carried out jointly by the Departments of Neonatology and Physiology, of IPGME & R and SSKM Hospital, Kolkata from June’ 2012 to September’ 2013. Normative statistics like ‘mean±2SD’ values for N1, P1 & N2 wave latencies of both right & left eyes & also for inter-peak amplitudes (i.e. N1-P1 & P1-N2 of both the eyes was obtained by studying 40 healthy, term newborns. It was also observed that the ‘latencies’ of VEP waves do not vary significantly between normal male & female newborn babies and the latencies of both the eyes are comparable. The ‘inter-peak amplitudes’ on the other hand showed much more variability. Hence establishing a normative database of VEP parameters can be of much use and further studies with much larger sample size is highly recommended.

  17. Studying energy evolution in the discharge chamber of a multichamber lightning protection system

    Science.gov (United States)

    Pinchuk, M. E.; Budin, A. V.; Kumkova, I. I.; Chusov, A. N.

    2016-04-01

    We present experimental data on the distribution of energy deposition along the discharge chamber of a multichamber lightning protection system at the initial stage of a discharge process modeling a lightning current pulse with 10 kA amplitude. The multichamber system comprised serially connected gas-discharge chambers. The breakdown between electrodes situated on the bottom of a channel in each chamber induces the formation of a shock wave. Subsequent energy evolution during the development of discharge proceeds in the entire volume bounded by the shock wave.

  18. Mind games : the effects of diazepam on Evoked Potentials

    NARCIS (Netherlands)

    Jongsma, Marie-Louise Albertien

    2000-01-01

    The electroencephalogram (EEG) represents the electrical activity of the brain. Evoked Potentials (EPs) are small voltage fluctuations in the EEG resulting from sensory, cognitive or motor evoked neural activity. Variations in the EP waveform may be caused by several factors. 1. By employing differe

  19. 21 CFR 882.1870 - Evoked response electrical stimulator.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Evoked response electrical stimulator. 882.1870... electrical stimulator. (a) Identification. An evoked response electrical stimulator is a device used to apply an electrical stimulus to a patient by means of skin electrodes for the purpose of measuring...

  20. MANAGEMENT OF VAGINAL DISCHARGE

    African Journals Online (AJOL)

    Enrique

    Vaginal infection is one of the top 25 reasons for women to consult doctors in the. USA. The 3 most common ... VAGINAL DISCHARGE IN POSTMENOPAUSAL WOMEN. In this age group, the .... More than one host fac- tor may be involved and ...

  1. Novel Molecular Discharges

    NARCIS (Netherlands)

    Hilbig, R.; Koerber, A.; Schwan, S.; Hayashi, D.

    2011-01-01

    A systematic investigation into halides and ~oxides showed the high potential of transition metal oxides as visible radiators for highly efficient gas discharge light sources. Zirconium monoxide (ZrO) has been identified as most promising candidate combining highly attractive green and red emission

  2. Electrical Discharge Machining.

    Science.gov (United States)

    Montgomery, C. M.

    The manual is for use by students learning electrical discharge machining (EDM). It consists of eight units divided into several lessons, each designed to meet one of the stated objectives for the unit. The units deal with: introduction to and advantages of EDM, the EDM process, basic components of EDM, reaction between forming tool and workpiece,…

  3. Flight Model Discharge System

    Science.gov (United States)

    1988-06-01

    Dielectric Sensor ................................... 12 5 ESA S/N 001 ......................................... 24 6 Preliminary Test Sequence...71 28 Optical Transmission Loss of Contamination "Witness" Slide 3 .................................. 72 29 Apparatus used in FMDS Spectroscopic...Monitor ( TPU ). This sensor detects the electromagnetic pulses generated by the onset of arcing. (2) An active discharge device (plasma source). (3) A

  4. Is the auditory evoked P2 response a biomarker of learning?

    Science.gov (United States)

    Tremblay, Kelly L; Ross, Bernhard; Inoue, Kayo; McClannahan, Katrina; Collet, Gregory

    2014-01-01

    Even though auditory training exercises for humans have been shown to improve certain perceptual skills of individuals with and without hearing loss, there is a lack of knowledge pertaining to which aspects of training are responsible for the perceptual gains, and which aspects of perception are changed. To better define how auditory training impacts brain and behavior, electroencephalography (EEG) and magnetoencephalography (MEG) have been used to determine the time course and coincidence of cortical modulations associated with different types of training. Here we focus on P1-N1-P2 auditory evoked responses (AEP), as there are consistent reports of gains in P2 amplitude following various types of auditory training experiences; including music and speech-sound training. The purpose of this experiment was to determine if the auditory evoked P2 response is a biomarker of learning. To do this, we taught native English speakers to identify a new pre-voiced temporal cue that is not used phonemically in the English language so that coinciding changes in evoked neural activity could be characterized. To differentiate possible effects of repeated stimulus exposure and a button-pushing task from learning itself, we examined modulations in brain activity in a group of participants who learned to identify the pre-voicing contrast and compared it to participants, matched in time, and stimulus exposure, that did not. The main finding was that the amplitude of the P2 auditory evoked response increased across repeated EEG sessions for all groups, regardless of any change in perceptual performance. What's more, these effects are retained for months. Changes in P2 amplitude were attributed to changes in neural activity associated with the acquisition process and not the learned outcome itself. A further finding was the expression of a late negativity (LN) wave 600-900 ms post-stimulus onset, post-training exclusively for the group that learned to identify the pre-voiced contrast.

  5. Is the auditory evoked P2 response a biomarker of learning?

    Directory of Open Access Journals (Sweden)

    Kelly eTremblay

    2014-02-01

    Full Text Available Even though auditory training exercises for humans have been shown to improve certain perceptual skills of individuals with and without hearing loss, there is a lack of knowledge pertaining to which aspects of training are responsible for the perceptual gains, and which aspects of perception are changed. To better define how auditory training impacts brain and behavior, electroencephalography and magnetoencephalography have been used to determine the time course and coincidence of cortical modulations associated with different types of training. Here we focus on P1-N1-P2 auditory evoked responses (AEP, as there are consistent reports of gains in P2 amplitude following various types of auditory training experiences; including music and speech-sound training. The purpose of this experiment was to determine if the auditory evoked P2 response is a biomarker of learning. To do this, we taught native English speakers to identify a new pre-voiced temporal cue that is not used phonemically in the English language so that coinciding changes in evoked neural activity could be characterized. To differentiate possible effects of repeated stimulus exposure and a button-pushing task from learning itself, we examined modulations in brain activity in a group of participants who learned to identify the pre-voicing contrast and compared it to participants, matched in time, and stimulus exposure, that did not. The main finding was that the amplitude of the P2 auditory evoked response increased across repeated EEG sessions for all groups, regardless of any change in perceptual performance. What’s more, these effects were retained for months. Changes in P2 amplitude were attributed to changes in neural activity associated with the acquisition process and not the learned outcome itself. A further finding was the expression of a late negativity (LN wave 600-900 ms post-stimulus onset, post-training, exclusively for the group that learned to identify the pre

  6. Auditory evoked potentials in peripheral vestibular disorder individuals

    Directory of Open Access Journals (Sweden)

    Matas, Carla Gentile

    2011-07-01

    Full Text Available Introduction: The auditory and vestibular systems are located in the same peripheral receptor, however they enter the CNS and go through different ways, thus creating a number of connections and reaching a wide area of the encephalon. Despite going through different ways, some changes can impair both systems. Such tests as Auditory Evoked Potentials can help find a diagnosis when vestibular alterations are seen. Objective: describe the Auditory Evoked Potential results in individuals complaining about dizziness or vertigo with Peripheral Vestibular Disorders and in normal individuals having the same complaint. Methods: Short, middle and long latency Auditory Evoked Potentials were performed as a transversal prospective study. Conclusion: individuals complaining about dizziness or vertigo can show some changes in BAEP (Brainstem Auditory Evoked Potential, MLAEP (Medium Latency Auditory Evoked Potential and P300.

  7. Multimodal evoked potential abnormalities in patients with Wilson's disease

    Directory of Open Access Journals (Sweden)

    Ilić Tihomir V.

    2005-01-01

    Full Text Available The aim of this study was to investigate the involvement of the following functional systems: somatosensory evoked potentials (SSEP, visual evoked potentials (VEP, and event related potentials (ERP, in twenty patients with Wilson's disease (WD. VEP and SSEP abnormalities were discovered in S patients respectively (40%, whereas ERP were either absent or, in the case of 10 patients (50%, had significantly prolonged P-300 latencies. Taken together, at least one evoked potential abnormality was discovered in 17 patients (85%]. Only in 3 patients (15%, involving either the isolated hepatic type of disease or short illness duration of the neurological type, were normal evoked potential findings observed. Our findings suggest the usefulness of multimodal evoked potential abnormalities in the evaluation of subclinical manifestations in patients with WD.

  8. Chirp-modulated visual evoked potential as a generalization of steady state visual evoked potential

    Science.gov (United States)

    Tu, Tao; Xin, Yi; Gao, Xiaorong; Gao, Shangkai

    2012-02-01

    Visual evoked potentials (VEPs) are of great concern in cognitive and clinical neuroscience as well as in the recent research field of brain-computer interfaces (BCIs). In this study, a chirp-modulated stimulation was employed to serve as a novel type of visual stimulus. Based on our empirical study, the chirp stimuli visual evoked potential (Chirp-VEP) preserved frequency features of the chirp stimulus analogous to the steady state evoked potential (SSVEP), and therefore it can be regarded as a generalization of SSVEP. Specifically, we first investigated the characteristics of the Chirp-VEP in the time-frequency domain and the fractional domain via fractional Fourier transform. We also proposed a group delay technique to derive the apparent latency from Chirp-VEP. Results on EEG data showed that our approach outperformed the traditional SSVEP-based method in efficiency and ease of apparent latency estimation. For the recruited six subjects, the average apparent latencies ranged from 100 to 130 ms. Finally, we implemented a BCI system with six targets to validate the feasibility of Chirp-VEP as a potential candidate in the field of BCIs.

  9. Analysis of generalized interictal discharges using quantitative EEG.

    Science.gov (United States)

    da Silva Braga, Aline Marques; Fujisao, Elaine Keiko; Betting, Luiz Eduardo

    2014-12-01

    Experimental evidence from animal models of the absence seizures suggests a focal source for the initiation of generalized spike-and-wave (GSW) discharges. Furthermore, clinical studies indicate that patients diagnosed with idiopathic generalized epilepsy (IGE) exhibit focal electroencephalographic abnormalities, which involve the thalamo-cortical circuitry. This circuitry is a key network that has been implicated in the initiation of generalized discharges, and may contribute to the pathophysiology of GSW discharges. Quantitative electroencephalogram (qEEG) analysis may be able to detect abnormalities associated with the initiation of GSW discharges. The objective of this study was to determine whether interictal GSW discharges exhibit focal characteristics using qEEG analysis. In this study, 75 EEG recordings from 64 patients were analyzed. All EEG recordings analyzed contained at least one GSW discharge. EEG recordings were obtained by a 22-channel recorder with electrodes positioned according to the international 10-20 system of electrode placement. EEG activity was recorded for 20 min including photic stimulation and hyperventilation. The EEG recordings were visually inspected, and the first unequivocally confirmed generalized spike was marked for each discharge. Three methods of source imaging analysis were applied: dipole source imaging (DSI), classical LORETA analysis recursively applied (CLARA), and equivalent dipole of independent components with cluster analysis. A total of 753 GSW discharges were identified and spatiotemporally analyzed. Source evaluation analysis using all three techniques revealed that the frontal lobe was the principal source of GSW discharges (70%), followed by the parietal and occipital lobes (14%), and the basal ganglia (12%). The main anatomical sources of GSW discharges were the anterior cingulate cortex (36%) and the medial frontal gyrus (23%). Source analysis did not reveal a common focal source of GSW discharges. However

  10. Combined application of three evoked potentials to improve the diagnosis of multiple sclerosis

    Institute of Scientific and Technical Information of China (English)

    Xiaoyi Li

    2006-01-01

    BACKGROUND:It is very important to find out the focal sites for the ealy diagnosis of multiple sclerosis,especially the discovery of tiny or potential focal site,so that multiple sclerosis can be diagnosed at the early poriod (the first attack)or when the focus has not displayed completely.and the evoked potential can discover the abnormality of the pathway between spinal cord to cerebral cortex.OBJECTIVE:To observe the values of motor evoked potential(MEP),somatosensory evoked potential(SEP) and evoked-related potential(P300)in the diagnosis of multiple sclerosis.DESIGN:A case-controlled study.SETFING:Neuroelectrophysiological Center of Guizhou Provincial People's Hospital. PARTICIPANTS:Twenty-five outpatients or inpatients with multiple sclerosis were selected from the Department of Neurology,Guizhou Provincial People's Hospital from October 2001 to March 2005.The patients were diagnosed according to the diagnostic standards of multiple sclerosis suggested by Poser et al. In 1983 and MRI examination.There were 17 males and 8 females,aged 18-65 years old With an average of 39 years.and their disease courses ranged from 6 months to 5 years.Meanwhile.30 healthy physical examinees were selected in our hospital as the control group,and they all had no abnormality by detailed inquisition.physical examination and examination of nervous system,including 15 males and 5 females,aged 20-66 years old.All the enrolled subjects were informed and agreed with the detections.METHODS:①The MEP,SEP and P300 were detected with synergy evoked potential equipment(Oxford Instruments,UK)in all the 25 patients with multiple sclerosis and 20 healthy subjects.②Standards for judging the abnormalities of evoked potentials:The abnormalities referred to deletion of wave form or the latency was prolonged by more than the reference value of normal subject±3SD.③The differences of measurement data were compared with the t test.MAIN OUTCOME MEASURES:The results of MEP,SEP and P300 in the 25

  11. Longer brainstem auditory evoked response latencies of individuals with fragile X syndrome related to sedation.

    Science.gov (United States)

    Miezejeski, C M; Heaney, G; Belser, R; Brown, W T; Jenkins, E C; Sersen, E A

    1997-04-18

    Brainstem auditory evoked response latencies were studies in 75 males (13 with fragile X syndrome, 18 with mental retardation due to other causes, and 44 with no disability). Latency values were obtained for each ear for the positive deflections of waves I (P1), III (P3), and V (P5). Some individuals with mental retardation required sedation. Contrary to previous report, latencies obtained for individuals with fragile X did not differ from those obtained for persons without mental retardation. Persons receiving sedation, whether or not their retardation was due to fragile X, had longer latencies for wave P5 than persons who did not receive sedation. This effect of sedation may also explain the previously reported increased latencies for persons with fragile X.

  12. ROLE OF NMDA, NICOTINIC, AND GABA RECEPTORS IN THE STEADY STATE VISUAL EVOKED POTENTIAL IN RATS.

    Science.gov (United States)

    This manuscript characterizes the receptor pathways involved in pattern-evoked potential generation in rats" NMDA and nicotinic acetylcholine receptors appear to be involved in the generation of the steady-state pattern evoked response in vivo." The pattern evok...

  13. Acute effects of passive stretching on the electromechanical delay and evoked twitch properties: a gender comparison.

    Science.gov (United States)

    Costa, Pablo B; Ryan, Eric D; Herda, Trent J; Walter, Ashley A; Hoge, Katherine M; Cramer, Joel T

    2012-12-01

    This study examined the acute effects of passive stretching on electromechanical delay (EMD), peak twitch force (PTF), rate of force development (RFD), and peak-to-peak M-wave (PPM) for the soleus muscle during evoked isometric plantar flexion muscle actions. Fourteen men (mean age ± SD = 21.2 ± 2.4 years; body mass = 80.0 ± 14.9 kg; height = 176.9 ± 7.2 cm) and 20 women (20.9 ± 2.5 years; 61.3 ± 8.9 kg; 165.3 ± 7.5 cm) volunteered for the study. Five single-square, supramaximal transcutaneous electrical stimuli (each separated by 5 s) were delivered to the tibial nerve before and after passive stretching. A time × gender interaction was observed for EMD, and the post hoc dependent-samples t tests indicated that EMD increased 4% for the women (p = .023), but not for the men (p = .191). There were no other stretching-related changes for PTF, RFD, or p-p M-wave for either the men or women (p > .05). These findings tentatively suggested that mechanical factors related to the stiffness of the muscle-tendon unit may contribute to the explanation for why stretching caused an acute increase in the EMD during evoked twitches in the women, but not in the men.

  14. Numerical Simulation of a Negative Impulsive Wave

    Institute of Scientific and Technical Information of China (English)

    ToshiakiSETOGUCHI; ShenYU; 等

    1996-01-01

    A compression wave discharged from an open end of a tube causes positive impulsive noise,Active noise cancellation which is the cancelling of the noise by the addition of an inverse wave is a useful technique for reducing impulsive noise,The main objective of this study is to present the design for a negative impulsive wave generator utilizing unsteady mass influx.In this paper,in order to clarify the relationship between the unsteady mass influx and the negative impulsive wave,numerical and aeroacoustic analyses have been carried out using an unsteady expansion wave discharged from an open end of a shock tube.As a result,the effect of an unsteady expansion wave on a negative impulsive wave was charified.

  15. Discharge pulse phenomenology

    Science.gov (United States)

    Frederickson, A. R.

    1985-01-01

    A model was developed which places radiation induced discharge pulse results into a unified conceptual framework. Only two phenomena are required to interpret all space and laboratory results: (1) radiation produces large electrostatic fields inside insulators via the trapping of a net space charge density; and (2) the electrostatic fields initiate discharge streamer plasmas similar to those investigated in high voltage electrical insulation materials; these streamer plasmas generate the pulsing phenomena. The apparent variability and diversity of results seen is an inherent feature of the plasma streamer mechanism acting in the electric fields which is created by irradiation of the dielectrics. The implications of the model are extensive and lead to constraints over what can be done about spacecraft pulsing.

  16. Electrical and mechanical characteristics of nanosecond pulsed sliding dielectric barrier discharges with different electrode gaps

    Science.gov (United States)

    Bayoda, K. D.; Benard, N.; Moreau, E.

    2015-10-01

    This study proposes the characterization of a surface sliding discharge that extends over a length of 80 mm. The gas ionization is caused by series of high voltage pulses with nanosecond rising and decaying times while ion drift is forced by a negative DC component. Different plasma diagnostics such as electrical measurements, iCCD visualizations and strioscopy have been performed. They highlight that a threshold mean electric field between both air-exposed electrodes is required to fully establish a sliding discharge. Compared to a single nanosecond pulsed dielectric barrier discharge, the sliding discharge results in an energy consumption increase. Moreover, the pressure wave induced by the discharge is strongly impacted.

  17. Electroretinography and Visual Evoked Potentials in Childhood Brain Tumor Survivors.

    Science.gov (United States)

    Pietilä, Sari; Lenko, Hanna L; Oja, Sakari; Koivisto, Anna-Maija; Pietilä, Timo; Mäkipernaa, Anne

    2016-07-01

    This population-based cross-sectional study evaluates the clinical value of electroretinography and visual evoked potentials in childhood brain tumor survivors. A flash electroretinography and a checkerboard reversal pattern visual evoked potential (or alternatively a flash visual evoked potential) were done for 51 survivors (age 3.8-28.7 years) after a mean follow-up time of 7.6 (1.5-15.1) years. Abnormal electroretinography was obtained in 1 case, bilaterally delayed abnormal visual evoked potentials in 22/51 (43%) cases. Nine of 25 patients with infratentorial tumor location, and altogether 12 out of 31 (39%) patients who did not have tumors involving the visual pathways, had abnormal visual evoked potentials. Abnormal electroretinographies are rarely observed, but abnormal visual evoked potentials are common even without evident anatomic lesions in the visual pathway. Bilateral changes suggest a general and possibly multifactorial toxic/adverse effect on the visual pathway. Electroretinography and visual evoked potential may have clinical and scientific value while evaluating long-term effects of childhood brain tumors and tumor treatment.

  18. Cortical evoked potentials recorded from the guinea pig without averaging.

    Science.gov (United States)

    Walloch, R A

    1975-01-01

    Potentials evoked by tonal pulses and recorded with a monopolar electrode on the pial surface over the auditory cortex of the guinea pig are presented. These potentials are compared with average potentials recorded in previous studies with an electrode on the dura. The potentials recorded by these two techniques have similar waveforms, peak latencies and thresholds. They appear to be generated within the same region of the cerebral cortex. As can be expected, the amplitude of the evoked potentials recorded from the pial surface is larger than that recorded from the dura. Consequently, averaging is not needed to extract the evoked potential once the dura is removed. The thresholds for the evoked cortical potential are similar to behavioral thresholds for the guinea pig at high frequencies; however, evoked potential thresholds are eleveate over behavioral thresholds at low frequencies. The removal of the dura and the direct recording of the evoked potential appears most appropriate for acute experiments. The recording of an evoked potential with dura electrodes empploying averaging procedures appears most appropriate for chronic studies.

  19. Electrostatic Discharge Training Manual

    Science.gov (United States)

    1980-09-01

    NAVSEA SE 003-AA-TRN-OO LEYE V ELECTROSTATIC DISCHARGE TRAINING MANUAL s DTIC ,T OF I!ELECTE, ,4MA 0W\\R 9 981 E PUBLISHED BY DIRECTION OF COMMANDER...AS: F (QIQ2 . . . ................................................. (1) WHERE: F = FORCE ( NEWTONS ) Q, AND Q2 = MAGNITUDES OF THE CHARGES (COULOMB) R...RATIONALIZED MKS UNITS IN EQUATION (1), WE HAVE: & I 9(5 X 1 - )(lO ř I ’ 32 I I I I. & I = .5 NEWTON

  20. Turbidity on the Shallow Reef off Kaulana and Hakioawa Watersheds, North Coast of Kaho`olawe, Hawai`iMeasurements of Turbidity and Ancillary Data on Winds, Waves, Precipitation, and Stream flow Discharge, November 2005 to June 2008

    Science.gov (United States)

    Presto, M. Katherine; Storlazzi, Curt D.; Field, Michael E.; Abbott, Lyman L.

    2010-01-01

    The island of Kaho`olawe has particular cultural and religious significance for native Hawaiians. Once known as Kanaloa, the island was a center for native Hawaiian navigation. In the mid-20th century, the island was used as a bombing range by the U.S. Navy, and that practice, along with the foraging by feral goats, led to a near-complete decimation of vegetation. The loss of ground cover led to greatly increased erosion and run-off of sediment-laden water onto the island's adjacent coral reefs. Litigation in 1990 ended the U.S. Navy's use of the island as a bombing range, and in 1994 the island was transferred to the Kaho`olawe Island Reserve Commission (KIRC), http://kahoolawe.hawaii.gov/. As a result of the litigation, the U.S. Navy began a 10-year clean-up effort that was the foundation for the present restoration effort by KIRC (Slay, 2009). The restoration effort is centered on revegetating the island, reducing erosion, and limiting run-off onto adjacent reefs. Restoration efforts to mitigate sediment runoff to streams and gulches by restoring native vegetation and minimizing erosion have focused on two watersheds, Kaulana and Hakioawa, on the northeast and northwest sides of the island, respectively. Stream flow and sediment gages were installed by the U.S. Geological Survey Pacific Islands Water Science Center in each of the watersheds, and a weather station was established upland of the watersheds. For this study, turbidity monitors were installed on the insular shelf off the two watersheds to monitor the overall quality of reef waters and their changes in response to rain and stream flow discharge events.

  1. Electrochemical Discharge Machining Process

    Directory of Open Access Journals (Sweden)

    Anjali V. Kulkarni

    2007-09-01

    Full Text Available Electrochemical discharge machining process is evolving as a promising micromachiningprocess. The experimental investigations in the present work substantiate this trend. In the presentwork, in situ, synchronised, transient temperature and current measurements have been carriedout. The need for the transient measurements arose due to the time-varying nature of the dischargeformation and time varying circuit current. Synchronised and transient measurements revealedthe discrete nature of the process. It also helped in formulating the basic mechanism for thedischarge formation and the material removal in the process. Temperature profile on workpieceand in electrochemical discharge machining cell is experimentally measured using pyrometer,and two varieties of K-type thermocouples. Surface topography of the discharge-affected zoneson the workpiece has been carried out using scanning electron microscope. Measurements andsurface topographical studies reveal the potential use of this process for machining in micronregime. With careful experimental set-up design, suitable supply voltage and its polarity, theprocess can be applied for both micromachining and micro-deposition. It can be extended formachining and or deposition of wide range of materials.

  2. Microhollow cathode discharges

    Science.gov (United States)

    Schoenbach, K. H.; Moselhy, M.; Shi, W.; Bentley, R.

    2003-07-01

    By reducing the dimensions of hollow cathodes into the hundred micrometer range, stable, direct current, high (atmospheric) pressure glow discharges in rare gases, rare gas-halide mixtures and in air could be generated. The electron energy distribution in these microdischarges is non-Maxwellian, with a pronounced high-energy tail. The high electron energy together with the high gas density, which favors three-body collisions, is the reason for an efficient excimer generation in these microplasmas. Excimer efficiencies from 1% to 9% have been measured for argon, xenon, argon fluoride, and xenon chloride direct current excimer emitters, with a radiant excimer emittance of up to 2 W/cm2 for xenon. Adding small amounts of oxygen to argon has allowed us to generate vacuum ultraviolet line radiation at 130.5 nm with an efficiency approaching 1%. Pulsing xenon discharges with nanosecond electrical pulses has led to an increase in intensity to 15 W/cm2 and to a simultaneous increase in efficiency to more than 20%. Operating the discharges in an abnormal glow mode has allowed us to generate microdischarge arrays without individual ballast. Applications of these plasma arrays are excimer lamps and plasma reactors.

  3. Modeling electronegative plasma discharge

    Energy Technology Data Exchange (ETDEWEB)

    Lichtenberg, A.J.; Lieberman, M.A. [Univ. of California, Berkley, CA (United States)

    1995-12-31

    Macroscopic analytic models for a three-component electronegative gas discharge are developed. Assuming the negative ions to be in Boltzmann equilibrium, a positive ion ambipolar diffusion equation is derived. The discharge consists of an electronegative core and electropositive edges. The electron density in the core is nearly uniform, allowing a parabolic approximation to the plasma profile to be employed. The resulting equilibrium equations are solved analytically and matched to a constant mobility transport model of an electropositive edge plasma. The solutions are compared to a simulation of a parallel-plane r.f. driven oxygen plasma for p = 50 mTorr and n{sub eo}= 2.4 x 10{sup 15} m{sup -3}. The ratio {alpha}{sub o} of central negative ion density to electron density, and the electron temperature T{sub e}, found in the simulation, are in reasonable agreement with the values calculated from the model. The model is extended to: (1) low pressures, where a variable mobility model is used in the electropositive edge region; and (2) high {alpha}{sub o} in which the edge region disappears. The inclusion of a second positive ion species, which can be very important in describing electronegative discharges used for materials processing, is a possible extension of the model.

  4. DEPOSITION CARBON NANOSTRUCTURES BY SURFATRON GENERATED DISCHARGE

    Directory of Open Access Journals (Sweden)

    Marina Davydova

    2014-12-01

    Full Text Available Carbon nanostructures were deposited by surface wave discharge using various Ar/CH4/ CO2 gas mixture ratios. The morphology was controlled by adjusting of gas concentration and was investigated by scanning electron microscopy (SEM. Also, the influence of the low temperature plasma treatment and process time on the wettability of the diamond films has been studied. The results indicate that for hydrogen termination of diamond surface indicate that the temperature as low as 400°C and treatment time of 15 min is sufficient to attain the p-type surface conductivity of diamond.

  5. Mechanical Stimulation by Postnasal Drip Evokes Cough.

    Directory of Open Access Journals (Sweden)

    Toshiyuki Iwata

    Full Text Available Cough affects all individuals at different times, and its economic burden is substantial. Despite these widespread adverse effects, cough research relies on animal models, which hampers our understanding of the fundamental cause of cough. Postnasal drip is speculated to be one of the most frequent causes of chronic cough; however, this is a matter of debate. Here we show that mechanical stimuli by postnasal drip cause chronic cough. We distinguished human cough from sneezes and expiration reflexes by airflow patterns. Cough and sneeze exhibited one-peak and two-peak patterns, respectively, in expiratory airflow, which were also confirmed by animal models of cough and sneeze. Transgenic mice with ciliary dyskinesia coughed substantially and showed postnasal drip in the pharynx; furthermore, their cough was completely inhibited by nasal airway blockade of postnasal drip. We successfully reproduced cough observed in these mice by injecting artificial postnasal drip in wild-type mice. These results demonstrated that mechanical stimulation by postnasal drip evoked cough. The findings of our study can therefore be used to develop new antitussive drugs that prevent the root cause of cough.

  6. Mechanical Stimulation by Postnasal Drip Evokes Cough.

    Science.gov (United States)

    Iwata, Toshiyuki; Ito, Isao; Niimi, Akio; Ikegami, Koji; Marumo, Satoshi; Tanabe, Naoya; Nakaji, Hitoshi; Kanemitsu, Yoshihiro; Matsumoto, Hisako; Kamei, Junzo; Setou, Mitsutoshi; Mishima, Michiaki

    2015-01-01

    Cough affects all individuals at different times, and its economic burden is substantial. Despite these widespread adverse effects, cough research relies on animal models, which hampers our understanding of the fundamental cause of cough. Postnasal drip is speculated to be one of the most frequent causes of chronic cough; however, this is a matter of debate. Here we show that mechanical stimuli by postnasal drip cause chronic cough. We distinguished human cough from sneezes and expiration reflexes by airflow patterns. Cough and sneeze exhibited one-peak and two-peak patterns, respectively, in expiratory airflow, which were also confirmed by animal models of cough and sneeze. Transgenic mice with ciliary dyskinesia coughed substantially and showed postnasal drip in the pharynx; furthermore, their cough was completely inhibited by nasal airway blockade of postnasal drip. We successfully reproduced cough observed in these mice by injecting artificial postnasal drip in wild-type mice. These results demonstrated that mechanical stimulation by postnasal drip evoked cough. The findings of our study can therefore be used to develop new antitussive drugs that prevent the root cause of cough.

  7. Transient evoked otoacoustic emissions in rock musicians.

    Science.gov (United States)

    Høydal, Erik Harry; Lein Størmer, Carl Christian; Laukli, Einar; Stenklev, Niels Christian

    2017-09-01

    Our focus in this study was the assessment of transient evoked otoacoustic emissions (TEOAEs) in a large group of rock musicians. A further objective was to analyse tinnitus among rock musicians as related to TEOAEs. The study was a cross-sectional survey of rock musicians selected at random. A control group was included at random for comparison. We recruited 111 musicians and a control group of 40 non-musicians. Testing was conducted by using clinical examination, pure tone audiometry, TEOAEs and a questionnaire. TEOAE SNR in the half-octave frequency band centred on 4 kHz was significantly lower bilaterally in musicians than controls. This effect was strongly predicted by age and pure-tone hearing threshold levels in the 3-6 kHz range. Bilateral hearing thresholds were significantly higher at 6 kHz in musicians. Twenty percent of the musicians had permanent tinnitus. There was no association between the TEOAE parameters and permanent tinnitus. Our results suggest an incipient hearing loss at 6 kHz in rock musicians. Loss of TEOAE SNR in the 4 kHz half-octave frequency band was observed, but it was related to higher mean 3-6 kHz hearing thresholds and age. A large proportion of rock musicians have permanent tinnitus.

  8. [Intraoperative monitoring of visual evoked potentials].

    Science.gov (United States)

    Sasaki, Tatsuya; Ichikawa, Tsuyoshi; Sakuma, Jun; Suzuki, Kyouichi; Matsumoto, Masato; Itakura, Takeshi; Kodama, Namio; Murakawa, Masahiro

    2006-03-01

    Our success rate of intraoperative monitoring of visual evoked potential (VEP) had been approximately 30% in the past. In order to improve recording rate of intraoperative VEP, we developed a new stimulating device using high power light emitting diodes. Electroretinogram was simultaneously recorded to understand whether flash stimulation reached the retina. In addition, total venous anesthesia with propofol was used to avoid the adverse effect of inhalation anesthesia. We report the results after introduction of these improvements. Intraoperative monitoring of VEP was attempted in 35 cases. We evaluated success rate of VEP recording, correlation between VEP findings and postoperative visual function, and reasons why recording was not successful. Stable and reproducible waveforms were obtained in 59 sides (84%). Two cases, whose VEP deteriorated intraoperatively, developed postoperative visual disturbance: In 11 sides (16%), stable waveforms were not obtained. There were two main causes. In 8 sides out of 11, the cause was attributed to pre-existing severe visual disturbance. In these 8 sides, VEP in the awake state was not recordable or was recordable, but with very low amplitudes under 1 microV. In the other 3 sides, the cause was attributed to movement of a stimulating device by reflecting the fronto-temporal scalp flap. In conclusion, the successful recording rate was increased to 84% from approximately 30%, after introduction of various trials. We need further improvement in recording intraoperative VEP to establish a reliable intraoperative monitoring method for VEP.

  9. Self-consistent spatio-temporal simulation of pulsed microwave discharge

    Energy Technology Data Exchange (ETDEWEB)

    Bonaventura, Z; Trunec, D; Mesko, M; Vasina, P; Kudrle, V [Department of Physical Electronics, Faculty of Science, Masaryk University, Kotlarska 2, 611 37 Brno (Czech Republic)

    2008-01-07

    A spatio-temporal theoretical model of pulsed microwave discharge was developed. This model is based on the macroscopic continuity equation for electrons and on the wave equation for an electromagnetic wave passing through the discharge plasma. These equations were solved together and in a self-consistent manner. For simplicity, the continuity equation was solved in one dimension only and the electromagnetic wave was assumed to be plane and transversal. Both equations were solved numerically and the spatio-temporal dependences of electron concentration and the amplitude of the microwave electric field were obtained. It was found that the discharge development depends, significantly, on the initial spatial distribution of electron concentration. Two different cases were studied: the discharge development during the first microwave pulse only and after several successive pulses. The calculations were performed particularly for the discharge in nitrogen. The results were compared with experimental data from our previous work.

  10. Spleen removal - open - adults - discharge

    Science.gov (United States)

    Splenectomy - adult - discharge; Spleen removal - adult - discharge ... You had surgery to remove your spleen. This operation is called splenectomy . The surgeon made a cut (incision) in the middle of your belly or on the left side ...

  11. Theory of gas discharge plasma

    CERN Document Server

    Smirnov, Boris M

    2015-01-01

    This book presents the theory of gas discharge plasmas in a didactical way. It explains the processes in gas discharge plasmas. A gas discharge plasma is an ionized gas which is supported by an external electric field. Therefore its parameters are determined by processes in it. The properties of a gas discharge plasma depend on its gas component, types of external fields, their geometry and regimes of gas discharge. Fundamentals of a gas discharge plasma include elementary, radiative and transport processes which are included in its kinetics influence. They are represented in this book together with the analysis of simple gas discharges. These general principles are applied to stationary gas discharge plasmas of helium and argon. The analysis of such plasmas under certain conditions is theoretically determined by numerical plasma parameters for given regimes and conditions.

  12. [Brainstem auditory evoked potentials and somatosensory evoked potentials in Chiari malformation].

    Science.gov (United States)

    Moncho, Dulce; Poca, María A; Minoves, Teresa; Ferré, Alejandro; Rahnama, Kimia; Sahuquillo, Juan

    2013-06-16

    Introduccion. La malformacion de Chiari (MC) incluye una serie de anomalias congenitas que tienen como comun denominador la ectopia de las amigdalas del cerebelo por debajo del foramen magno, lo que puede condicionar fenomenos compresivos del troncoencefalo, la medula espinal alta y los nervios craneales, alterando las respuestas de los potenciales evocados auditivos del tronco cerebral (PEATC) y de los potenciales evocados somatosensoriales (PESS). Sin embargo, las indicaciones de ambas exploraciones en las MC han sido motivo de estudio en un numero limitado de publicaciones, centradas en series cortas y heterogeneas de pacientes. Objetivo. Revisar los hallazgos de los PEATC y los PESS en los estudios publicados en pacientes con MC tipo 1 (MC-1) o tipo 2 (MC-2), y su indicacion en el diagnostico, tratamiento y seguimiento, especialmente en la MC-1. Desarrollo. Es un estudio de revision realizado mediante analisis de los estudios publicados en Medline desde 1966, localizados mediante PubMed, utilizando combinaciones de las palabras clave 'Chiari malformation', 'Arnold-Chiari malformation', 'Chiari type 1 malformation', 'Arnold-Chiari type 1 malformation', 'evoked potentials', 'brainstem auditory evoked potentials' y 'somatosensory evoked potentials', asi como informacion de pacientes con MC-1 valorados en los servicios de neurocirugia y neurofisiologia clinica del Hospital Universitari Vall d'Hebron. Conclusiones. Los hallazgos mas comunes de los PESS son la reduccion en la amplitud cortical para el nervio tibial posterior, la reduccion o ausencia del potencial cervical del nervio mediano y el aumento del intervalo N13-N20. En el caso de los PEATC, los hallazgos mas frecuentes descritos son el aumento del intervalo I-V y la alteracion periferica o coclear.

  13. Calcium transient evoked by nicotine in isolated rat vagal pulmonary sensory neurons.

    Science.gov (United States)

    Xu, Jennings; Yang, Wenbin; Zhang, Guangfan; Gu, Qihai; Lee, Lu-Yuan

    2007-01-01

    It has been shown that inhaled cigarette smoke activates vagal pulmonary C fibers and rapidly adapting receptors (RARs) in the airways and that nicotine contained in the smoke is primarily responsible. This study was carried out to determine whether nicotine alone can activate pulmonary sensory neurons isolated from rat vagal ganglia; the response of these neurons was determined by fura-2-based ratiometric Ca(2+) imaging. The results showed: 1) Nicotine (10(-4) M, 20 s) evoked a transient increase in intracellular Ca(2+) concentration ([Ca(2+)](i)) in 175 of the 522 neurons tested (Delta[Ca(2+)](i) = 142.2 +/- 12.3 nM); the response was reproducible, with a small reduction in peak amplitude in the same neurons when the challenge was repeated 20 min later. 2) A majority (59.7%) of these nicotine-sensitive neurons were also activated by capsaicin (10(-7) M). 3) 1,1-Dimethyl-4-phenylpiperazinium iodide (DMPP; 10(-4) M, 20 s), a selective agonist of the neuronal nicotinic acetylcholine receptors (NnAChRs), evoked a pattern of response similar to that of nicotine. 4) The responses to nicotine and DMPP were either totally abrogated or markedly attenuated by hexamethonium (10(-4) M). 5) In anesthetized rats, right atrial bolus injection of nicotine (75-200 mug/kg) evoked an immediate (latency <1-2 s) and intense burst of discharge in 47.8% of the pulmonary C-fiber endings and 28.6% of the RARs tested. In conclusion, nicotine exerts a direct stimulatory effect on vagal pulmonary sensory nerves, and the effect is probably mediated through an activation of the NnAChRs expressed on the membrane of these neurons.

  14. Evoked potentials and head injury. 1. Rating of evoked potential abnormality.

    Science.gov (United States)

    Rappaport, M; Hall, K; Hopkins, H K; Belleza, T

    1981-10-01

    This paper describes a method for rating the degree of abnormality of auditory, visual and somatosensory evoked potential patterns in head injury (HI) patients. Criteria for judging degree of EP abnormality are presented that allow assessment of the extent and severity of subcortical and cortical dysfunction associated with traumatic brain damage. Interrater reliability data based upon blind ratings of normal and HI patients are presented and shown to be highly significant. Tables of normative values of peak latencies and amplitudes are given and illustrations of EP patterns of different degrees of abnormality are presented.

  15. Plasma Discharge Process in a Pulsed Diaphragm Discharge System

    Science.gov (United States)

    Duan, Jianjin; Hu, Jue; Zhang, Chao; Wen, Yuanbin; Meng, Yuedong; Zhang, Chengxu

    2014-12-01

    As one of the most important steps in wastewater treatment, limited study on plasma discharge process is a key challenge in the development of plasma applications. In this study, we focus on the plasma discharge process of a pulsed diaphragm discharge system. According to the analysis, the pulsed diaphragm discharge proceeds in seven stages: (1) Joule heating and heat exchange stage; (2) nucleated site formation; (3) plasma generation (initiation of the breakdown stage); (4) avalanche growth and plasma expansion; (5) plasma contraction; (6) termination of the plasma discharge; and (7) heat exchange stage. From this analysis, a critical voltage criterion for breakdown is obtained. We anticipate this finding will provide guidance for a better application of plasma discharges, especially diaphragm plasma discharges.

  16. Postoperative changes in visual evoked potentials and cognitive function tests following sevoflurane anaesthesia.

    LENUS (Irish Health Repository)

    Iohom, G

    2012-02-03

    We tested the hypothesis that minor disturbance of the visual pathway persists following general anaesthesia even when clinical discharge criteria are met. To test this, we measured visual evoked potentials (VEPs) in 13 ASA I or II patients who did not receive any pre-anaesthetic medication and underwent sevoflurane anaesthesia. VEPs were recorded on four occasions, before anaesthesia and at 30, 60, and 90 min after emergence from anaesthesia. Patients completed visual analogue scales (VAS) for sedation and anxiety, a Trieger Dot Test (TDT) and a Digit Symbol Substitution Test (DSST) immediately before each VEP recording. These results were compared using Student\\'s t-test. P<0.05 was considered significant. VEP latency was prolonged (P<0.001) and amplitude diminished (P<0.05) at 30, 60, and 90 min after emergence from anaesthesia, when VAS scores for sedation and anxiety, TDT, and DSST had returned to pre-anaesthetic levels.

  17. Synaptic origin of rhythmic visually evoked activity in kitten area 17 neurones.

    Science.gov (United States)

    Bringuier, V; Fregnac, Y; Debanne, D; Shulz, D; Baranyi, A

    1992-12-01

    Rhythmic patterns in neuronal activity in response to moving stimuli were observed in 28% of cells recorded extracellularly or intracellularly in area 17 of 4-16 week old anaesthetized and paralysed kittens. In both recording modes, oscillation frequencies ranged between 7 and 71 Hz, and were confined for 88% of cells in the 7-20 Hz band of the spectrum. A comparative study of firing autocorrelograms) and subthreshold activity (autocorrelation functions) indicates that the regularity of discharge stemmed from visually evoked oscillations of membrane potential at the same frequency. These oscillations are shown to result from extrinsic excitatory activity, since their amplitude, but not their frequency, depends on the resting membrane potential. The dependency on stimulus configuration supports the hypothesis that oscillations in neuronal output are dictated by periodic activity in afferent circuits selectively recruited by different attributes of the visual input which are not exclusively processed at the cortical level.

  18. Influence of muscular fatigue in evoked electromyogram

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, J; Acevedo, R; Tabernig, C [Rehabilitation Engineering and Neuromuscular and Sensorial Research Laboratory, National University of Entre Rios (Argentina)

    2007-11-15

    In this work we present the results of the evaluation of the changes happened in M wave during application of functional electrical stimulation. Electromyogram from the tibialis anterior muscle and ankle angle were measured to determine the occurrence of the fatigue phenomenon. The results report a decrease of the signal amplitude and the median of the power spectrum and are encouraging for the development of strategies of control of FES applications.

  19. The Relationship between Polarographic Reduction Potentials and Discharge Properties of Disperse Dyes

    Institute of Scientific and Technical Information of China (English)

    LONG Jia-jie; CHENG Wan-li; WANG Hui-zhen; TANG Ren-cheng; FAN Bing-xian

    2005-01-01

    The half-wave potentials of disperse dyes with different structures are measured, the relationship between half-wave potentials and their discharge properties is discussed, then their effect factors are studied, such as the chemical structure types and substituents of disperse dyes and technological parameters. The results indicate that the halfwave potentials of disperse dyes when reduced could be used to characterize their reducing and discharge properties.

  20. Runaway electrons preionized diffuse discharges at high pressure

    Science.gov (United States)

    Tarasenko, Victor F.; Lomaev, Mikhail I.; Sorokin, Dmitry A.

    2010-09-01

    Breakdown of the gaps with a non-uniform electric field filled with nitrogen and air as well as with other gases under high-voltage nanosecond pulses was investigated. It is shown that conditions of obtaining a diffuse discharge without a source of additional ionization are extended at the voltage pulse duration decreasing. A volume discharge is formed due to the gap pre-ionization by runaway electrons and X-ray quanta. At a negative polarity of the electrode with a small radius of curvature, a volume (diffuse) discharge formation is determined by pre-ionization with runaway electrons which are generated due to the electric field amplification near the cathode and in the gap. At a positive polarity of the electrode with a small radius of curvature, the X-ray radiation, generated at the runaway electrons braking at the anode and in the gap, is of great importance in a volume discharge formation. A runaway electrons preionized diffuse discharge (REP DD) has two characteristic stages. In the first stage, the ionization wave overlaps the gap during a fraction of a second. The discharge current is determined by the conductivity current in the dense plasma of the ionization wave and the displacement current in the remaining part of the gap. The second stage of the discharge can be related to the anomalous glow discharge with a high specific input power. During the second stage, the gap voltage decreases and the cathode spots formed as a result of explosive electron emission can participate in the electron emission from the cathode. At the increase of the voltage pulse duration and specific input power, the REP DD transforms into a spark discharge form. A REP DD is easily realized in various gases and at different pressures; see [1] and references in [1]. At pressure decrease was obtained the anode electrons beam current to rise (up to ~2 kA/cm2 in helium). At the REP DD, the anode is influenced by the plasma of a dense nanosecond discharge with the specific input power

  1. Multimodality evoked responses in the neurological assessment of the newborn.

    Science.gov (United States)

    Mercuri, E; von Siebenthal, K; Daniëls, H; Guzzetta, F; Casaer, P

    1994-09-01

    In recent years increased attention has been devoted to evoked potentials (EP) in newborns. This paper reviews the literature and data from our research group in an attempt to assess the diagnostic and prognostic value of evoked responses in the first weeks of life and their use in different age-specific clinical conditions. The results show that EP are a very sensitive measure of the integrity of the sensory pathways. They make it possible to follow normal physiological maturation and the abnormalities of development resulting from neurological lesions. Repeated measurements of visual evoked potentials and somatosensorial evoked potential are prognostically useful in term infants, but seem much more limited in preterm newborns in predicting neurodevelopmental outcome.

  2. Towards a neural basis of music-evoked emotions.

    Science.gov (United States)

    Koelsch, Stefan

    2010-03-01

    Music is capable of evoking exceptionally strong emotions and of reliably affecting the mood of individuals. Functional neuroimaging and lesion studies show that music-evoked emotions can modulate activity in virtually all limbic and paralimbic brain structures. These structures are crucially involved in the initiation, generation, detection, maintenance, regulation and termination of emotions that have survival value for the individual and the species. Therefore, at least some music-evoked emotions involve the very core of evolutionarily adaptive neuroaffective mechanisms. Because dysfunctions in these structures are related to emotional disorders, a better understanding of music-evoked emotions and their neural correlates can lead to a more systematic and effective use of music in therapy.

  3. Compact Intracloud Discharges

    Energy Technology Data Exchange (ETDEWEB)

    Smith, David A. [Univ. of Colorado, Boulder, CO (United States)

    1998-11-01

    In November of 1993, mysterious signals recorded by a satellite-borne broadband VHF radio science experiment called Blackboard led to a completely unexpected discovery. Prior to launch of the ALEXIS satellite, it was thought that its secondary payload, Blackboard, would most often detect the radio emissions from lightning when its receiver was not overwhelmed by noise from narrowband communication carriers. Instead, the vast majority of events that triggered the instrument were isolated pairs of pulses that were one hundred times more energetic than normal thunderstorm electrical emissions. The events, which came to be known as TIPPs (for transionospheric pulse pairs), presented a true mystery to the geophysics community. At the time, it was not even known whether the events had natural or anthropogenic origins. After two and one half years of research into the unique signals, two ground-based receiver arrays in New Mexico first began to detect and record thunderstorm radio emissions that were consistent with the Blackboard observations. On two occasions, the ground-based systems and Blackboard even recorded emissions that were produced by the same exact events. From the ground based observations, it has been determined that TIPP events areproduced by brief, singular, isolated, intracloud electrical discharges that occur in intense regions of thunderstorms. These discharges have been dubbed CIDS, an acronym for compact intracloud discharges. During the summer of 1996, ground-based receiver arrays were used to record the electric field change signals and broadband HF emissions from hundreds of CIDS. Event timing that was accurate to within a few microseconds made possible the determination of source locations using methods of differential time of arrival. Ionospheric reflections of signals were recorded in addition to groundwave/line-of-sight signals and were used to determine accurate altitudes for the discharges. Twenty-four CIDS were recorded from three

  4. Laser evoked potentials in carpal tunnel syndrome.

    Science.gov (United States)

    de Tommaso, Marina; Libro, Giuseppe; Difruscolo, Olimpia; Sardaro, Michele; Serpino, Claudia; Calabrese, Rita; Vecchio, Eleonora; Livrea, Paolo

    2009-02-01

    The aim of this study was to evaluate the function of Adelta fibers at the hand level in patients with clinical symptoms of Carpal Tunnel Syndrome (CTS) using CO(2) laser evoked potentials (LEPs), in light of the intensity and distribution of sensory symptoms and pain. Thirty-four CTS outpatients (62 hands) were compared to 23 sex- and age-matched control subjects (46 hands). The periungueal skin of the first, second, third and fifth fingers, and the dorsum of the hands were stimulated in random order. The latency and amplitude of the N2, P2 and N1 components were evaluated with respect to the Nerve Conduction Study (NCS) data, clinical scales, pain intensity and glove-like symptoms distribution. The amplitude of the N2-P2 complex was significantly reduced in CTS hands compared to normal hands after stimulation of the second and third fingers, even in patients with mild nerve conduction impairment. No significant fifth finger LEP abnormalities were found in patients with glove-like distribution symptoms. The N2-P2 amplitude at the second and third fingers was positively correlated with the severity of sensory symptoms. The involvement of median nerve Adelta fibers in CTS seems to be an early phenomenon, which concurs with the impairment of large motor and sensory afferents and is linked to the severity of the disease. The finding of reduced sensory symptoms in patients with severe thin afferents damage, may suggest a slight expression of central sensitisation phenomena in the advanced stage of CTS syndrome.

  5. Pudendal somatosensory evoked potentials in normal women

    Directory of Open Access Journals (Sweden)

    Geraldo A. Cavalcanti

    2007-12-01

    Full Text Available OBJECTIVE: Somatosensory evoked potential (SSEP is an electrophysiological test used to evaluate sensory innervations in peripheral and central neuropathies. Pudendal SSEP has been studied in dysfunctions related to the lower urinary tract and pelvic floor. Although some authors have already described technical details pertaining to the method, the standardization and the influence of physiological variables in normative values have not yet been established, especially for women. The aim of the study was to describe normal values of the pudendal SSEP and to compare technical details with those described by other authors. MATERIALS AND METHODS: The clitoral sensory threshold and pudendal SSEP latency was accomplished in 38 normal volunteers. The results obtained from stimulation performed on each side of the clitoris were compared to ages, body mass index (BMI and number of pregnancies. RESULTS: The values of clitoral sensory threshold and P1 latency with clitoral left stimulation were respectively, 3.64 ± 1.01 mA and 37.68 ± 2.60 ms. Results obtained with clitoral right stimulation were 3.84 ± 1.53 mA and 37.42 ± 3.12 ms, respectively. There were no correlations between clitoral sensory threshold and P1 latency with age, BMI or height of the volunteers. A significant difference was found in P1 latency between nulliparous women and volunteers who had been previously submitted to cesarean section. CONCLUSIONS: The SSEP latency represents an accessible and reproducible method to investigate the afferent pathways from the genitourinary tract. These results could be used as normative values in studies involving genitourinary neuropathies in order to better clarify voiding and sexual dysfunctions in females.

  6. Electromagnetic Waves

    DEFF Research Database (Denmark)

    This book is dedicated to various aspects of electromagnetic wave theory and its applications in science and technology. The covered topics include the fundamental physics of electromagnetic waves, theory of electromagnetic wave propagation and scattering, methods of computational analysis...

  7. Spatiotemporal mapping of interictal epileptiform discharges in human absence epilepsy: A MEG study

    NARCIS (Netherlands)

    Rozendaal, Y.J.W.; Luijtelaar, E.L.J.M. van; Ossenblok, P.P.W.

    2016-01-01

    PURPOSE: Although absence epilepsy is considered to be a prototypic type of generalized epilepsy, it is still under debate whether generalized 3 Hz spike-and-wave discharges (SWDs) might have a cortical focal origin. Here it is investigated whether focal interictal epileptiform discharges (IEDs),

  8. Single granule cells reliably discharge targets in the hippocampal CA3 network in vivo.

    Science.gov (United States)

    Henze, Darrell A; Wittner, Lucia; Buzsáki, György

    2002-08-01

    Processing of neuronal information depends on interactions between the anatomical connectivity and cellular properties of single cells. We examined how these computational building blocks work together in the intact rat hippocampus. Single spikes in dentate granule cells, controlled intracellularly, generally failed to discharge either interneurons or CA3 pyramidal cells. In contrast, trains of spikes effectively discharged both CA3 cell types. Increasing the discharge rate of the granule cell increased the discharge probability of its target neuron and decreased the delay between the onset of a granule cell train and evoked firing in postsynaptic targets. Thus, we conclude that the granule cell to CA3 synapses are 'conditional detonators,' dependent on granule cell firing pattern. In addition, we suggest that information in single granule cells is converted into a temporal delay code in target CA3 pyramidal cells and interneurons. These data demonstrate how a neural circuit of the CNS may process information.

  9. Continuous pile discharging machine

    Science.gov (United States)

    Smith, Phillips P.

    1976-05-11

    A device for discharging cartridges from tubes under fluid pressure includes a cylindrical housing adapted to be seated in a leak-tight manner on the end of one of the tubes, a chute depending from the cylindrical housing near the end seated on the end of the tube, a rotatable piston having a wrench on the forward end thereof disposed in the cylindrical housing and adapted to manipulate a plug in the end of the tube, and a telescopic hydraulic ram adapted to move the piston toward the plug. In addition the wrench contains a magnet which prevents inadvertent uncoupling of the wrench and the plug.

  10. The dreamy state: hallucinations of autobiographic memory evoked by temporal lobe stimulations and seizures.

    Science.gov (United States)

    Vignal, Jean-Pierre; Maillard, Louis; McGonigal, Aileen; Chauvel, Patrick

    2007-01-01

    Using results from cortical stimulations, as well as the symptoms of spontaneous epileptic seizures recorded by stereoelectroencephalography we re-studied the phenomenon of the dreamy state, as described by Jackson (Jackson JH. Selected writings of John Hughlins Jackson. Vol 1. On epilepsy and epileptiform convulsions. Taylor J, editor. London: Hodder and Stoughton; 1931). A total of 15 sensations of déjà vécu, 35 visual hallucinations consisting of the image of a scene and 5 'feelings of strangeness' occurred. These were recorded during 40 stimulations in 16 subjects, and 15 seizures in 5 subjects. Forty-five per cent of dreamy states were evoked by stimulation of the amygdala, 37.5% by the hippocampus and 17.5% by the para-hippocampal gyrus. During both spontaneous and provoked dreamy state, the electrical discharge was localized within mesial temporal lobe structures, without involvement of the temporal neocortex. Early spread of the discharge to the temporal neocortex appeared to prevent the occurrence of the dreamy state. Semiological analysis showed a clinical continuity between déjà vécu and visual hallucinations, the latter often consisting of a personal memory that was 'relived' by the subject; such memories could be recent, distant or from childhood. With one exception, the particular memory evoked differed from one seizure to another, but were always drawn from the same period of the subject's life. Given the role of the amygdala and hippocampus in autobiographic memory, their pathological activation during seizures may trigger memory recall. This study of the dreamy state is in keeping with other evidence demonstrating the constant and central role of the amygdala and hippocampus (right as much as left) in the recall of recent and distant memories. It demonstrates the existence of large neural networks that produce recall of memories via activation of the hippocampus, amygdala and rhinal cortex.

  11. Brain-immune interaction accompanying odor-evoked autobiographic memory.

    Science.gov (United States)

    Matsunaga, Masahiro; Bai, Yu; Yamakawa, Kaori; Toyama, Asako; Kashiwagi, Mitsuyoshi; Fukuda, Kazuyuki; Oshida, Akiko; Sanada, Kazue; Fukuyama, Seisuke; Shinoda, Jun; Yamada, Jitsuhiro; Sadato, Norihiro; Ohira, Hideki

    2013-01-01

    The phenomenon in which a certain smell evokes a specific memory is known as the Proust phenomenon. Odor-evoked autobiographic memories are more emotional than those elicited by other sensory stimuli. The results of our previous study indicated that odor-evoked autobiographic memory accompanied by positive emotions has remarkable effects on various psychological and physiological activities, including the secretion of cytokines, which are immune-signaling molecules that modulate systemic inflammation. In this study, we aimed to clarify the neural substrates associated with the interaction between odor-evoked autobiographic memory and peripheral circulating cytokines. We recruited healthy male and female volunteers and investigated the association between brain responses and the concentration of several cytokines in the plasma by using positron emission tomography (PET) recordings when an autographic memory was evoked in participants by asking them to smell an odor that was nostalgic to them. Participants experienced positive emotions and autobiographic memories when nostalgic odors were presented to them. The levels of peripheral proinflammatory cytokines, such as the tumor necrosis factor-α (TNF-α) and interferon-γ (IFN-γ), were significantly reduced after experiencing odor-evoked autobiographic memory. Subtraction analysis of PET images indicated that the medial orbitofrontal cortex (mOFC) and precuneus/posterior cingulate cortex (PCC) were significantly activated during experiences of odor-evoked autobiographic memory. Furthermore, a correlation analysis indicated that activities of the mOFC and precuneus/PCC were negatively correlated with IFN-γ concentration. These results indicate that the neural networks including the precuneus/PCC and mOFC might regulate the secretion of peripheral proinflammatory cytokines during the experience of odor-evoked autobiographic memories accompanied with positive emotions.

  12. Multiple Color Stimulus Induced Steady State Visual Evoked Potentials

    Science.gov (United States)

    2007-11-02

    evoked potentials, multiple color, FFT, bispectrum I. INTRODUCTION Visual evoked potential ( VEP ) is the electrical response of...brain under visual stimulation, which can be recorded from the scalp over the visual cortex of the brain. A distinction is made between transient VEP ...and steady-state VEP (SSVEP) based on the stimulation frequencies. The former arises when the stimulation frequencies are less than 2 Hz. However

  13. Investigating the periodicity of transient-evoked otoacoustic emission envelopes

    DEFF Research Database (Denmark)

    Verhulst, Sarah

    2011-01-01

    This study investigates the cochlear origin of the multiple temporal lobes that are often observed in the transient-evoked otoacoustic emission (TEOAE) envelope. This "waxing and waning" of the OAE amplitude can be observed in tone-burst (TB) OAEs and sometimes also in click-evoked (CE) OAEs. TBOAE...... and the middle-ear boundary may contribute to the TBOAE envelope periodicity, but were not the main modulation component in waxing and waning of the investigated TBOAEs....

  14. Auditory evoked potentials and vestibular evoked myogenic potentials in evaluation of brainstem lesions in multiple sclerosis.

    Science.gov (United States)

    Ivanković, Anita; Nesek Mađarić, Vesna; Starčević, Katarina; Krbot Skorić, Magdalena; Gabelić, Tereza; Adamec, Ivan; Habek, Mario

    2013-05-15

    The aim of this study was to determine the roles of magnetic resonance imaging (MRI), auditory evoked potentials (AEP) and vestibular evoked myogenic potentials (VEMP) in the evaluation of brainstem involvement in multiple sclerosis (MS). Altogether 32 patients with the diagnosis of MS participated in the study. The following data was collected from all patients: age, gender, Expanded Disability Status Scale (EDSS) score, brainstem functional system score (BSFS) (part of the EDSS evaluating brainstem symptomatology), and involvement of the brainstem on the brain MRI. AEP and ocular VEMP (oVEMP) and cervical VEMP (cVEMP) were studied in all patients. BSFS, MRI, AEP, oVEMP and cVEMP involvement of the brainstem was evident in 9 (28.1%), 14 (43.8%), 7 (21.9%), 12 (37.5%) and 10 (31.0%) patients, respectively. None of the tests used showed statistically significant advantage in the detection of brainstem lesions. When combining oVEMP and cVEMP 18 (56.3%) patients showed brainstem involvement. This combination showed brainstem involvement in greater percentage than BSFS or AEP, with statistical significance (p=0.035 and p=0.007, respectively). VEMP is a reliable method in detection of brainstem involvement in MS. It is comparable with MRI, but superior to clinical examination or AEP. Copyright © 2013 Elsevier B.V. All rights reserved.

  15. Cognitive Evoked Potential Measurement, P300, in a group of healthy Colombian individuals

    Directory of Open Access Journals (Sweden)

    Natalia Gutiérrez Giraldo

    2013-05-01

    Full Text Available Cognitive evoked potentials are electrophysiological measurements of cognitive functions. Cognitivepotential P300 is specifically related to attention processes. Objetive: the aim of this studywas to establish reference values for latency and amplitude of P300 wave in the Colombian population and determine their variability with age, gender and education of the subjects. Methods:we studied 122 healthy subjects between 6 and 80 years, are practical potential measurementmethodology as odd-ball, in leads Cz and Pz. Results: we were able to establish reference valuesfor different age groups, and statistical significance was found with which the latency of P300wave increases with the age of individuals, and instead thereof the amplitude tends to decrease.Similarly to correlate latency and amplitude was shown an inverse relationship between them.Conclusions: no differences were found for latency and wave amplitude, gender-related or schoolsubjects as well as no difference was found when measuring the Pz derivation obtained comparedwith the wave in lead Cz.

  16. The Duration of Motor Responses Evoked with Intracortical Microstimulation in Rats Is Primarily Modulated by Stimulus Amplitude and Train Duration.

    Directory of Open Access Journals (Sweden)

    Meghan Watson

    Full Text Available Microstimulation of brain tissue plays a key role in a variety of sensory prosthetics, clinical therapies and research applications, however the effects of stimulation parameters on the responses they evoke remain widely unknown. In particular, the effects of parameters when delivered in the form of a stimulus train as opposed to a single pulse are not well understood despite the prevalence of stimulus train use. We aimed to investigate the contribution of each parameter of a stimulus train to the duration of the motor responses they evoke in forelimb muscles. We used constant-current, biphasic, square wave pulse trains in acute terminal experiments under ketamine anaesthesia. Stimulation parameters were systematically tested in a pair-wise fashion in the caudal forelimb region of the motor cortex in 7 Sprague-Dawley rats while motor evoked potential (MEP recordings from the forelimb were used to quantify the influence of each parameter in the train. Stimulus amplitude and train duration were shown to be the dominant parameters responsible for increasing the total duration of the MEP, while interphase interval had no effect. Increasing stimulus frequency from 100-200 Hz or pulse duration from 0.18-0.34 ms were also effective methods of extending response durations. Response duration was strongly correlated with peak time and amplitude. Our findings suggest that motor cortex intracortical microstimulations are often conducted at a higher frequency rate and longer train duration than necessary to evoke maximal response duration. We demonstrated that the temporal properties of the evoked response can be both predicted by certain response metrics and modulated via alterations to the stimulation signal parameters.

  17. Evoked Culture and Evoked Nature: The Promise of Gene-Culture Co-Evolution Theory for Sociology

    OpenAIRE

    Walsh, Anthony; Yun, Ilhong

    2016-01-01

    The traditional sociological view of culture has been almost exclusively that of transmitted culture decoupled from biology. The concept of evoked culture brings biology “back in” since it identifies ecological challenges that evoked certain practices based on evolutionary imperatives. The practices are then passed on to subsequent generations as normative, and individuals best suited to these normative practices will enjoy greater fitness benefits than those less suited. In other words, prac...

  18. Somatosensory Evoked Potential Findings in Ankylosing Spondylitis

    Science.gov (United States)

    Cidem, Muharrem; Sahin, Zerrin; Aydin, Teoman; Aysal, Fikret

    2014-01-01

    Objective: Somatosensory evoked potential (SSEP) abnormalities were reported in patients with ankylosing spondylitis (AS). This study aimed to investigate SSEP abnormalities and its relation with clinical findings in AS patients. Materials and Methods: The study included 26 patients with AS and 17 age-matched health volunteers (Control for SSEP). Median nerve SSEP findings were normal in all AS cases. Results: However, delayed latency and/or very low amplitude of tibial nerve SSEP was found in 20 (76.9%) AS patients. There were significant correlations between tibial SSEP latency and disease duration (R=0.433 to 0.635). There was also an inverse correlation between tibial SSEP amplitude and disease duration (R=−0.429, p=0.047). Serum estradiol level, hip total bone mineral density, The Bath Ankylosing Spondylitis Functional Index (BASFI) score and Beck depression score were significantly lower in AS patients with SSEP abnormalities (37.3±10.8 pg/mL, 0.916±0.123 g/cm2, 35.0±27.9, 12.8±8.4, respectively) than in AS patients without SSEP abnormalities (53.7±12.3 pg/mL, 1.103±0.197 g/cm2, 64.8±15.5, 24.8±10.1, respectively). Conclusion: Significant inverse correlations between SSEP latencies and dehydroepiandrosterone sulphate (DHEAS) levels were found (R=−0.400 to −0.713). There were also significant inverse correlation between SSEP latencies and DHEAS/oestrogen index (R=−0.596 to −0.868), and between SSEP latencies and DHEAS/Progesterone index (R=−0.467 to −0.685). As a conclusion, this study indicates that tibial nerve SSEP abnormalities are common in patients with AS and there are significant correlations between clinical findings of AS and SSEP abnormalities. PMID:25610293

  19. Characteristics of brainstem auditory evoked potential of neonates with mild or moderate hyperbilirubinemia

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    BACKGROUND: Brainstem auditory evoked potential (BAEP) has been widely used to evaluate the functional integrity and development of injured auditory system and brain, especially to objectively evaluate the function of auditory system and brain stem of very young babies, such as neonates and sick babies.OBJECTIVE: To observe the changes of BAEP of neonates with hyperbilirubinemia, and to investigate the relationship of bilirubin concentration and BAEP.DESIGN: An observation experiment.SETTING: Department of Pediatrics, the 309 Clinical Division, General Hospital of Chinese PLA.PARTICIPANTS: Fifty-eight neonates with mild or moderate hyperbilirubinemia exhibiting jaundice within 24 hours after born, who received the treatment in the Department of Pediatrics, the 309 Clinical Division, General Hospital of Chinese PLA between January 2004 and May 2007, were recruited in this study. The involved neonates, 31 boys and 27 girls, had gestational age of 37 to 46 weeks. They had no history of birth asphyxia, and were scored 8 to 10 points when born. Written informed consents of examination and treatment were obtained from the guardians of the neonates. This study was approved by the Hospital Ethics Committee. According to serum total bilirubin value, the neonates were assigned into 3 groups: low-concentration bilirubin group (n =16), moderate-concentration bilirubin group (n =27) and high-concentration bilirubin group (n =15). According to mean daily bilirubin increase, the subjects were sub-assigned into bilirubin rapid increase group (n =39) and bilirubin slow increase group (n =19).METHODS: After admission, all the neonates received drug treatment. Meanwhile, their 116 ears were examined with a myoelectricity evoked potential equipment (KEYPOINT) in latency, wave duration,amplitude and wave shape differentiation of each wave of BAEP. BAEP abnormal type was observed and abnormal rate of BAEP was calculated.MAIN OUTCOME MEASURES: ① Abnormal rate and abnormal type of BAEP

  20. The paradox of music-evoked sadness: an online survey.

    Directory of Open Access Journals (Sweden)

    Liila Taruffi

    Full Text Available This study explores listeners' experience of music-evoked sadness. Sadness is typically assumed to be undesirable and is therefore usually avoided in everyday life. Yet the question remains: Why do people seek and appreciate sadness in music? We present findings from an online survey with both Western and Eastern participants (N = 772. The survey investigates the rewarding aspects of music-evoked sadness, as well as the relative contribution of listener characteristics and situational factors to the appreciation of sad music. The survey also examines the different principles through which sadness is evoked by music, and their interaction with personality traits. Results show 4 different rewards of music-evoked sadness: reward of imagination, emotion regulation, empathy, and no "real-life" implications. Moreover, appreciation of sad music follows a mood-congruent fashion and is greater among individuals with high empathy and low emotional stability. Surprisingly, nostalgia rather than sadness is the most frequent emotion evoked by sad music. Correspondingly, memory was rated as the most important principle through which sadness is evoked. Finally, the trait empathy contributes to the evocation of sadness via contagion, appraisal, and by engaging social functions. The present findings indicate that emotional responses to sad music are multifaceted, are modulated by empathy, and are linked with a multidimensional experience of pleasure. These results were corroborated by a follow-up survey on happy music, which indicated differences between the emotional experiences resulting from listening to sad versus happy music. This is the first comprehensive survey of music-evoked sadness, revealing that listening to sad music can lead to beneficial emotional effects such as regulation of negative emotion and mood as well as consolation. Such beneficial emotional effects constitute the prime motivations for engaging with sad music in everyday life.

  1. The paradox of music-evoked sadness: an online survey.

    Science.gov (United States)

    Taruffi, Liila; Koelsch, Stefan

    2014-01-01

    This study explores listeners' experience of music-evoked sadness. Sadness is typically assumed to be undesirable and is therefore usually avoided in everyday life. Yet the question remains: Why do people seek and appreciate sadness in music? We present findings from an online survey with both Western and Eastern participants (N = 772). The survey investigates the rewarding aspects of music-evoked sadness, as well as the relative contribution of listener characteristics and situational factors to the appreciation of sad music. The survey also examines the different principles through which sadness is evoked by music, and their interaction with personality traits. Results show 4 different rewards of music-evoked sadness: reward of imagination, emotion regulation, empathy, and no "real-life" implications. Moreover, appreciation of sad music follows a mood-congruent fashion and is greater among individuals with high empathy and low emotional stability. Surprisingly, nostalgia rather than sadness is the most frequent emotion evoked by sad music. Correspondingly, memory was rated as the most important principle through which sadness is evoked. Finally, the trait empathy contributes to the evocation of sadness via contagion, appraisal, and by engaging social functions. The present findings indicate that emotional responses to sad music are multifaceted, are modulated by empathy, and are linked with a multidimensional experience of pleasure. These results were corroborated by a follow-up survey on happy music, which indicated differences between the emotional experiences resulting from listening to sad versus happy music. This is the first comprehensive survey of music-evoked sadness, revealing that listening to sad music can lead to beneficial emotional effects such as regulation of negative emotion and mood as well as consolation. Such beneficial emotional effects constitute the prime motivations for engaging with sad music in everyday life.

  2. The Paradox of Music-Evoked Sadness: An Online Survey

    Science.gov (United States)

    Taruffi, Liila; Koelsch, Stefan

    2014-01-01

    This study explores listeners’ experience of music-evoked sadness. Sadness is typically assumed to be undesirable and is therefore usually avoided in everyday life. Yet the question remains: Why do people seek and appreciate sadness in music? We present findings from an online survey with both Western and Eastern participants (N = 772). The survey investigates the rewarding aspects of music-evoked sadness, as well as the relative contribution of listener characteristics and situational factors to the appreciation of sad music. The survey also examines the different principles through which sadness is evoked by music, and their interaction with personality traits. Results show 4 different rewards of music-evoked sadness: reward of imagination, emotion regulation, empathy, and no “real-life” implications. Moreover, appreciation of sad music follows a mood-congruent fashion and is greater among individuals with high empathy and low emotional stability. Surprisingly, nostalgia rather than sadness is the most frequent emotion evoked by sad music. Correspondingly, memory was rated as the most important principle through which sadness is evoked. Finally, the trait empathy contributes to the evocation of sadness via contagion, appraisal, and by engaging social functions. The present findings indicate that emotional responses to sad music are multifaceted, are modulated by empathy, and are linked with a multidimensional experience of pleasure. These results were corroborated by a follow-up survey on happy music, which indicated differences between the emotional experiences resulting from listening to sad versus happy music. This is the first comprehensive survey of music-evoked sadness, revealing that listening to sad music can lead to beneficial emotional effects such as regulation of negative emotion and mood as well as consolation. Such beneficial emotional effects constitute the prime motivations for engaging with sad music in everyday life. PMID:25330315

  3. Cortical evoked potentials to an auditory illusion: binaural beats.

    Science.gov (United States)

    Pratt, Hillel; Starr, Arnold; Michalewski, Henry J; Dimitrijevic, Andrew; Bleich, Naomi; Mittelman, Nomi

    2009-08-01

    To define brain activity corresponding to an auditory illusion of 3 and 6Hz binaural beats in 250Hz or 1000Hz base frequencies, and compare it to the sound onset response. Event-Related Potentials (ERPs) were recorded in response to unmodulated tones of 250 or 1000Hz to one ear and 3 or 6Hz higher to the other, creating an illusion of amplitude modulations (beats) of 3Hz and 6Hz, in base frequencies of 250Hz and 1000Hz. Tones were 2000ms in duration and presented with approximately 1s intervals. Latency, amplitude and source current density estimates of ERP components to tone onset and subsequent beats-evoked oscillations were determined and compared across beat frequencies with both base frequencies. All stimuli evoked tone-onset P(50), N(100) and P(200) components followed by oscillations corresponding to the beat frequency, and a subsequent tone-offset complex. Beats-evoked oscillations were higher in amplitude with the low base frequency and to the low beat frequency. Sources of the beats-evoked oscillations across all stimulus conditions located mostly to left lateral and inferior temporal lobe areas in all stimulus conditions. Onset-evoked components were not different across stimulus conditions; P(50) had significantly different sources than the beats-evoked oscillations; and N(100) and P(200) sources located to the same temporal lobe regions as beats-evoked oscillations, but were bilateral and also included frontal and parietal contributions. Neural activity with slightly different volley frequencies from left and right ear converges and interacts in the central auditory brainstem pathways to generate beats of neural activity to modulate activities in the left temporal lobe, giving rise to the illusion of binaural beats. Cortical potentials recorded to binaural beats are distinct from onset responses. Brain activity corresponding to an auditory illusion of low frequency beats can be recorded from the scalp.

  4. Modification of the Steel Surface Treated by a Volume Discharge Plasma in Nitrogen at Atmospheric Pressure

    Science.gov (United States)

    Erofeev, M. V.; Shulepov, M. A.; Ivanov, Yu. F.; Oskomov, K. V.; Tarasenko, V. F.

    2016-03-01

    Effect of volume discharge plasma initiated by an avalanche electron beam on the composition, structure, and properties of the surface steel layer is investigated. Voltage pulses with incident wave amplitude up to 30 kV, full width at half maximum of about 4 ns, and wave front of about 2.5 ns were applied to the gap with an inhomogeneous electric field. Changes indicating the hardening effect of the volume discharge initiated by an avalanche electron beam are revealed in St3-grade steel specimens treated by the discharge of this type.

  5. Investigation of heavy current discharges with high initial gas density

    Energy Technology Data Exchange (ETDEWEB)

    Budin, A.; Bogomaz, A.; Kolikov, V.; Kuprin, A.; Leontiev, V.; Rutberg, P.; Shirokov, N. [Institute of Problems of Electrophysics of Russian Academy of Sciences, Dvortsovayanab., 18, St. Petersburg, 191065 (Russia)

    1996-05-01

    Piezoelectric pressure transducers, with noise immunity and time resolution of 0,5 {mu}s were used to measure pulse pressures of 430 MPa along the axis of an electrical discharge channel. Initial concentration of He was 2,7{center_dot}10{sup 21}cm{sup {minus}3}, dI/dt=6{center_dot}10{sup 11}A/s, and I{sub max}=560kA. Shock waves with amplitudes exceeding the pressure along the axis, were detected by a pressure transducer on the wall of the discharge chamber. Typical shock velocities were 2{center_dot}4km/s. Average pressure measurements along the discharge axis at different radii were used to estimate the current density distribution along the canal radius. The presence of the shock waves, promoting the additional hydrogen heating in the discharge chamber, has been registered during the discharge in hydrogen for I{sub max}{approximately}1MA and an initial concentration of 10{sup 21}cm{sup {minus}3}. {copyright} {ital 1996 American Institute of Physics.}

  6. Dynamics of VUV spectra in fast capillary discharge

    Science.gov (United States)

    Antsiferov, P. S.; Dorokhin, L. A.; Koshelev, K. N.

    2011-09-01

    The temporal behavior of VUV spectra of capillary discharge with a rate of a current rise on the order of 1012 A/s is studied. The current is generated using an inductive storage unit with a plasma-erosion opening switch. This discharge is accompanied by the generation of a shock wave on an inner wall of a capillary and by its subsequent cumulation on the discharge axis. The capillary is prefilled with argon at a pressure of 80 Pa. Radiation spectra are obtained using an off-Rowland spectrograph based on a concave grating with optimal focusing in the wavelength range of 20 nm. The radiation is recorded with a detector based on a microchannel plate with a time resolution of 20 ns, which makes it possible to separate the spectra of two phases of the discharge, i.e., the cumulation phase of the shock wave in argon that fills the capillary ( T e ˜ 20-30 eV) and the phase of subsequent discharge in a substance desorbed from the capillary wall T e ˜ 50 eV).

  7. Do twisted laser beams evoke nuclear hyperpolarization?

    Science.gov (United States)

    Schmidt, A. B.; Andrews, D. L.; Rohrbach, A.; Gohn-Kreuz, C.; Shatokhin, V. N.; Kiselev, V. G.; Hennig, J.; von Elverfeldt, D.; Hövener, J.-B.

    2016-07-01

    The hyperpolarization of nuclear spins promises great advances in chemical analysis and medical diagnosis by substantially increasing the sensitivity of nuclear magnetic resonance (NMR). Current methods to produce a hyperpolarized sample, however, are arduous, time-consuming or costly and require elaborate equipment. Recently, a much simpler approach was introduced that holds the potential, if harnessed appropriately, to revolutionize the production of hyperpolarized spins. It was reported that high levels of hyperpolarization in nuclear spins can be created by irradiation with a laser beam carrying orbital angular momentum (twisted light). Aside from these initial reports however, no further experimental verification has been presented. In addition, this effect has so far evaded a critical theoretical examination. In this contribution, we present the first independent attempt to reproduce the effect. We exposed a sample of immersion oil or a fluorocarbon liquid that was placed within a low-field NMR spectrometer to Laguerre-Gaussian and Bessel laser beams at a wavelength of 514.5 nm and various topological charges. We acquired 1H and 19F NMR free induction decay data, either during or alternating with the irradiation that was parallel to B0. We observed an irregular increase in NMR signal in experiments where the sample was exposed to beams with higher values of the topological charge. However, at no time did the effect reach statistical significance of 95%. Given the measured sensitivity of our setup, we estimate that a possible effect did not exceed a hyperpolarization (at 5 mT) of 0.14-6%, depending on the assumed hyperpolarized volume. It should be noted though, that there were some differences between our setup and the previous implementation of the experiment, which may have inhibited the full incidence of this effect. To approach a theoretical description of this effect, we considered the interaction of an electron with a plane wave, which is known to be

  8. Brain-stem auditory evoked responses during microvascular decompression for trigeminal neuralgia: Predicting post-operative hearing loss

    Directory of Open Access Journals (Sweden)

    Ramnarayan Ramachandran

    2006-01-01

    Full Text Available Context: The importance of brainstem auditory evoked potential monitoring in reducing hearing loss during microvascular decompression for trigeminal neuralgia is now accepted. However the extent of the changes in the pattern of these potentials and the safe limits to which these changes are relevant in reducing postoperative hearing loss have not been established. Aims: The aim of this study is to quantify these changes and relate these to the postoperative hearing loss. Settings and Design: This study was done at the Walton Centre for neurology and neurosurgery, Liverpool, United Kingdom. The study was designed to give a measure of the change in the wave pattern following microvascular decompression and relate it to postoperative hearing loss. Materials and Methods: Seventy-five patients undergoing microvascular decompression for trigeminal neuralgia had preoperative and postoperative hearing assessments and intraoperative brainstem auditory evoked potential monitoring. Statistical Analysis Used: Chi-square tests. Results: It was found that the wave V latency was increased by more than 0.9ms in nine patients, eight of whom suffered significant postoperative hearing loss as demonstrated by audiometry. It was also seen that progressive decrease in amplitude of wave V showed progressive hearing loss with 25% loss when amplitude fell by 50 and 100% loss when wave V was lost completely. However most of the patients did not have a clinically manifest hearing loss. Conclusions: A per-operative increase in the latency of wave V greater than 0.9 ms and a fall of amplitude of wave V of more than 50% indicates a risk to hearing.

  9. [Evoked potentials and regional cerebral blood flow changes in conversion disorder: a case report and review].

    Science.gov (United States)

    Gürses, Nadide; Temuçin, Cağri Mesut; Lay Ergün, Eser; Ertuğrul, Aygün; Ozer, Suzan; Demir, Başaran

    2008-01-01

    Conversion disorder is defined as the presence of functional impairment in motor, sensory or neurovegetative systems which cannot be explained by a general medical condition. Although the diagnostic systems emphasize the absence of an organic basis for the dysfunction in conversion disorder, there has been a growing interest in the specific functional brain correlates of conversion symptoms in recent years, particularly by examining neuroimaging and neurophysiological measures. In this case report, regional cerebral blood flow changes and evoked potentials of a patient with conversion symptoms are presented. Somatosensory evoked potentials (SEP) of this patient with conversion disorder who had signs of movement disorder revealed that the latency to N20, P 25 waves were in normal limits while the amplitudes of the P25 and N33 components were extremely high (giant SEP). Regional cerebral blood flow assessment revealed hypoperfusion in the left parietal and temporal lobes of the brain. Three months after the first assessment, the control scans showed that the left parietal hypoperfusion disappeared while the left temporal hypoperfusion was still present. The following SEP evaluations which were repeated twice in three months intervals after the initial recordings, showed the persistence of the abnormalities in somatosensorial measures. The neurophysiological and neuroimaging findings in conversion disorder were reviewed and the results of the evaluations of this case were discussed in this article.

  10. A novel method of brainstem auditory evoked potentials using complex verbal stimuli

    Directory of Open Access Journals (Sweden)

    Sophia N Kouni

    2014-01-01

    Full Text Available Background: The click and tone-evoked auditory brainstem responses are widely used in clinical practice due to their consistency and predictability. More recently, the speech-evoked responses have been used to evaluate subcortical processing of complex signals, not revealed by responses to clicks and tones. Aims: Disyllable stimuli corresponding to familiar words can induce a pattern of voltage fluctuations in the brain stem resulting in a familiar waveform, and they can yield better information about brain stem nuclei along the ascending central auditory pathway. Materials and Methods: We describe a new method with the use of the disyllable word "baba" corresponding to English "daddy" that is commonly used in many other ethnic languages spanning from West Africa to the Eastern Mediterranean all the way to the East Asia. Results: This method was applied in 20 young adults institutionally diagnosed as dyslexic (10 subjects or light dyslexic (10 subjects who were matched with 20 sex, age, education, hearing sensitivity, and IQ-matched normal subjects. The absolute peak latencies of the negative wave C and the interpeak latencies of A-C elicited by verbal stimuli "baba" were found to be significantly increased in the dyslexic group in comparison with the control group. Conclusions: The method is easy and helpful to diagnose abnormalities affecting the auditory pathway, to identify subjects with early perception and cortical representation abnormalities, and to apply the suitable therapeutic and rehabilitation management.

  11. Can a finding of cervical vestibular evoked myogenic potentials contribute to vestibular migraine diagnostics?

    Directory of Open Access Journals (Sweden)

    Tihana Vešligaj

    2016-02-01

    Full Text Available Aim To investigate differences in vestibular evoked myogenic potentials (VEMP results with patients suffering from vestibular migraine and healthy people, taking into consideration values of threshold and latency of occurrence of the characteristic wave complex, size of amplitude, and interaural amplitude ratio. According to the results, determine the importance and usefulness of VEMP in vestibular migraine diagnostics. Methods A total number of 62 subjects were included in the study, 32 of them belonging to a group of patients suffering from vestibular migraine (VM, while other 30 were in a control group of healthy subjects. Information was collected during the diagnostic evaluation. General and otoneurological history of patients and bedside tests, audiological results, videonystagmography and cervical vestibular evoked myogenic potentials (cVEMP were made. Results There was a difference in an interaural ratio of amplitudes in the experimental and control groups, but it was not found to be clinically significant. By ToneBurst 500 Hz method, the interaural amplitude ratio higher than 35% was measured in 46.97% subjects, while the response was totally unilaterally missing in 28.8% patients. Conclusion Even the sophisticated method as cVEMP does not give the ultimate result confirming the vestibular migraine diagnosis, and neither do other diagnostic methods. cVEMP result can contribute to the completion of full mosaic of vestibular migraine diagnostics.

  12. Pulsed electrical discharges for medicine and biology techniques, processes, applications

    CERN Document Server

    Kolikov, Victor

    2015-01-01

    This book presents the application of pulsed electrical discharges in water and water dispersions of metal nanoparticles in medicine (surgery, dentistry, and oncology), biology, and ecology. The intensive electrical and shock waves represent a novel technique to destroy viruses and this way to  prepare anti-virus vaccines. The method of pulsed electrical discharges in water allows to decontaminate water from almost all known bacteria and spores of fungi being present in human beings. The nanoparticles used are not genotoxic and mutagenic. This book is useful for researchers and graduate students.

  13. Effect of Electrohydraulic Discharge on Viscosity of Human Blood

    Directory of Open Access Journals (Sweden)

    G. M. El-Aragi

    2013-01-01

    Full Text Available Electrohydraulic plasma discharge is a novel technology with high efficiency and high speed and can generate chemically active species like free radicals, ions, atoms, and metastables, accompanied by ultraviolet light emission and shock pressure waves. The aim of this work is to examine the effect of electrohydraulic discharge (EHD system on viscosity of the human blood after different exposure time. The voltage pulsation introduces electric field and temperature jump and at the same time leads to haemolysis of the blood cells. The ratio of blood viscosity under the influence of magnetic field to the viscosity in the absence of magnetic field is directly proportional to the applied magnetic field .

  14. A Comprehensive Review on Methodologies Employed for Visual Evoked Potentials.

    Science.gov (United States)

    Kothari, Ruchi; Bokariya, Pradeep; Singh, Smita; Singh, Ramji

    2016-01-01

    Visual information is fundamental to how we appreciate our environment and interact with others. The visual evoked potential (VEP) is among those evoked potentials that are the bioelectric signals generated in the striate and extrastriate cortex when the retina is stimulated with light which can be recorded from the scalp electrodes. In the current paper, we provide an overview of the various modalities, techniques, and methodologies which have been employed for visual evoked potentials over the years. In the first part of the paper, we cast a cursory glance on the historical aspect of evoked potentials. Then the growing clinical significance and advantages of VEPs in clinical disorders have been briefly described, followed by the discussion on the earlier and currently available methods for VEPs based on the studies in the past and recent times. Next, we mention the standards and protocols laid down by the authorized agencies. We then summarize the recently developed techniques for VEP. In the concluding section, we lay down prospective research directives related to fundamental and applied aspects of VEPs as well as offering perspectives for further research to stimulate inquiry into the role of visual evoked potentials in visual processing impairment related disorders.

  15. Linear superposition of sensory-evoked and ongoing cortical hemodynamics

    Directory of Open Access Journals (Sweden)

    Mohamad Saka

    2010-08-01

    Full Text Available Modern non-invasive brain imaging techniques utilise changes in cerebral blood flow, volume and oxygenation that accompany brain activation. However, stimulus-evoked hemodynamic responses display considerable inter-trial variability even when identical stimuli are presented and the sources of this variability are poorly understood. One of the sources of this response variation could be ongoing spontaneous hemodynamic fluctuations. To investigate this issue, 2-dimensional optical imaging spectroscopy was used to measure cortical hemodynamics in response to sensory stimuli in anaesthetised rodents Pre-stimulus cortical hemodynamics displayed spontaneous periodic fluctuations and as such, data from individual stimulus presentation trials were assigned to one of four groups depending on the phase angle of pre-stimulus hemodynamic fluctuations and averaged. This analysis revealed that sensory evoked cortical hemodynamics displayed distinctive response characteristics and magnitudes depending on the phase angle of ongoing fluctuations at stimulus onset. To investigate the origin of this phenomenon, ‘null-trails’ were collected without stimulus presentation. Subtraction of phase averaged ‘null trials’ from their phase averaged stimulus-evoked counterparts resulted in four similar time series that resembled the mean stimulus-evoked response. These analyses suggest that linear superposition of evoked and ongoing cortical hemodynamic changes may be a property of the structure of inter-trial variability.

  16. Transformation of oil-and-gas reservoir with shock waves by high current pulsed discharge ignited energetic materials explosion%脉冲大电流放电引爆含能材料产生冲击波的储层改造

    Institute of Scientific and Technical Information of China (English)

    周海滨; 刘巧珏; 赵有志; 张永民; 丁卫东

    2016-01-01

    介绍了复合电热化学法产生冲击波的机理和冲击波改善储层物性的机制;给出了脉冲大电流引爆含能材料弹丸的结构和典型的放电参数,开展了冲击波致裂储层的实验研究;检测了样品在冲击作用下的动态应变及影响储层解吸附特性的关键参数(包括孔隙度、渗透率、抗拉、抗压强度等),并在实验前后进行了测量和对比.研究表明,电热化学法产生的冲击波可在圆柱形砂岩样品上产生幅值为 1000με~1500με的应变量,使砂岩出现了宏观裂缝;样品平均孔隙度由 15.24%增至 15.62%,平均渗透率由 1.749 09×10-3μm2增至2.467 08×10-3μm2;抗压、抗拉和抗剪强度均下降了约 30%.%Composite electro-thermal chemical explosion (CETCE)was used to generate strong shock waves (SWs).This paper introduces the mechanism and effects of SWs generated by CETCE on reservoir stimulation and gives the discharge parame-ters and discharge load structure used to ignite energetic materials (EMs).The SW fracturing effects experiments were carried out.The dynamic strain and desorption related parameters,including porosity,permeability,strengths of extension and compres-sion were measured and compared with those before the shock experiments.The results show that,the SWs generated by CETCE can generate the dynamic strain of 1000με-1500με,and visual cracks appear on and in the samples.The average porosity of sam-ple increases from 15.24% to 15.62%,average permeability increases from 1.749 09×10-3μm2 to 2.467 08×10-3μm2,and strengths of extension,compression and shear decrease by about 30% overall.

  17. Formation of white-eye pattern with microdischarge in an air dielectric barrier discharge system

    CERN Document Server

    He, Yafeng; Liu, Weili; Wang, Hongfang; Zhao, Zengchao; Fan, Weili

    2011-01-01

    We report on the first observation of white-eye pattern in an air dielectric barrier discharge. The patterned discharges undergo a development as following: random spots - quasihexagonal pattern - hexagonal pattern (type I) - hexagonal pattern (type II) - white-eye pattern - chaos as the voltage is increased. The spatiotemporal characteristics of patterned discharges are investigated by using an optical method. Results show that the two discharge modes, uniform mode and filamentary mode, are actually two different spatial presentations of the same origin: the microdischarge. From the viewpoint of pattern dynamics, the white-eye pattern results from a 3-wave resonance interaction.

  18. Visually Evoked Potentials in a Patient with a Fyodorov-Zuev Keratoprosthesis

    Directory of Open Access Journals (Sweden)

    Roy Schwartz

    2015-01-01

    Full Text Available Purpose: To describe a visually evoked potential (VEP examination performed on a patient with a keratoprosthesis. Methods: We report the case of a 60-year-old patient with a Fyodorov-Zuev keratoprosthesis in the right eye complained of gradual visual deterioration in that eye. His past medical history consisted of failed corneal graft procedures due to corneal dystrophy and an Ahmed valve implantation due to secondary glaucoma. A clinical examination and an ultrasound demonstrated vitreal opacities. In order to assess the visual status, a flash VEP test was conducted. Results: VEP recorded from the right eye consisted of a broadened and poorly formed positive P1 wave, with a subnormal amplitude, but a normal latency. Consequently, the patient underwent a pars plana vitrectomy. Conclusion: This case demonstrates the viability of VEP exams in patients with keratoprostheses.

  19. Early changes of auditory brain stem evoked response after radiotherapy for nasopharyngeal carcinoma - a prospective study

    Energy Technology Data Exchange (ETDEWEB)

    Lau, S.K.; Wei, W.I.; Sham, J.S.T.; Choy, D.T.K.; Hui, Y. (Queen Mary Hospital, Hong Kong (Hong Kong))

    1992-10-01

    A prospective study of the effect of radiotherapy for nasopharyngeal carcinoma on hearing was carried out on 49 patients who had pure tone, impedance audiometry and auditory brain stem evoked response (ABR) recordings before, immediately, three, six and 12 months after radiotherapy. Fourteen patients complained of intermittent tinnitus after radiotherapy. We found that 11 initially normal ears of nine patients developed a middle ear effusion, three to six months after radiotherapy. There was mixed sensorineural and conductive hearing impairment after radiotherapy. Persistent impairment of ABR was detected immediately after completion of radiotherapy. The waves I-III and I-V interpeak latency intervals were significantly prolonged one year after radiotherapy. The study shows that radiotherapy for nasopharyngeal carcinoma impairs hearing by acting on the middle ear, the cochlea and the brain stem auditory pathway. (Author).

  20. Habituation of single CO2 laser-evoked responses during interictal phase of migraine.

    Science.gov (United States)

    de Tommaso, Marina; Libro, Giuseppe; Guido, Marco; Losito, Luciana; Lamberti, Paolo; Livrea, Paolo

    2005-09-01

    A reduced habituation of averaged laser-evoked potential (LEP) amplitudes was previously found in migraine patients. The aim of the present study was to assess the habituation of single LEP responses and pain sensation during the interictal phase in migraine patients. Fourteen migraine patients were compared with ten control subjects. The pain stimulus was laser pulses, generated by CO2 laser, delivered to right supraorbital zone. Patients were evaluated during attack-free conditions. The LEP habituation was studied by measuring the changes of LEP amplitudes across and within three consecutive repetitions of 21 non-averaged trials. In migraine patients the N2-P2 wave amplitudes did not show a tendency toward habituation across and, above all, within the three repetitions. Anomalous behaviour of nociceptive cortex during the interictal phase of migraine may predispose patients to headache occurrence and persistence.

  1. Evaluation of Visual Evoked Potential (VEP) in Patients With Chronic Obstructive Pulmonary Disease (COPD).

    Science.gov (United States)

    Karthikkeyan, Kanmani; Padma, K; Rao, B Vishwanatha

    2015-01-01

    Chronic Obstructive Pulmonary Disease (COPD), a progressive and partially reversible disease, has drawn world-wide attention for its moderate prevalence rate and causing central and peripheral neuropathy. Considering its severity in causing visual pathway impairment, the present investigation was carried out to find out the functional integrity of the visual pathway through visual evoked potentials (VEP) and to determine the factors influencing the condition in COPD patients. A total of 30 COPD patients of both sexes, classified according to the severity of the disease based on spirometric indices, were subjected to VEP testing and series of wave forms were measured and compared with equal number of control subjects. The latency of N75 and P100 were prolonged (P VEP changes. Non-invasive procedure can possibly be utilized as a routine screening test for COPD patients for better medical care.

  2. Aberrant lateralization of brainstem auditory evoked responses by individuals with Down syndrome.

    Science.gov (United States)

    Miezejeski, C M; Heaney, G; Belser, R; Sersen, E A

    1994-01-01

    Brainstem auditory evoked response latencies were studied in 80 males (13 with Down syndrome, 23 with developmental disability due to other causes, and 44 with no disability). Latencies for waves P3 and P5 were shorter for the Down syndrome than for the other groups, though at P5, as compared to latencies for the nondisabled group, the difference was not significant. The pattern of left versus right ear responses in the Down syndrome group differed from those of the other groups. This finding was related to research noting decreased lateralization of and decreased ability at receptive and expressive language among people with Down syndrome. Some individuals required sedation. A lateralized effect of sedation was noted.

  3. Middle latency auditory evoked responses in normal term infants: a longitudinal study.

    Science.gov (United States)

    Rogers, S H; Edwards, D A; Henderson-Smart, D J; Pettigrew, A G

    1989-05-01

    Middle latency auditory evoked responses (MLAERs) were measured in 21 normal term infants, three to five days after birth and then at 6 weeks, 7 months and 1 year of age. A polyphasic waveform was elicited during natural sleep in all infants at each recording session by monaural click stimulation at a rate of 9 per second. A 70 dBHL stimulus was found to be optimal as the MLAER became less well defined when the stimulus intensity approached the threshold hearing level. The first 60 to 70 msec of the waveform was found to be most stable, with decreasing detectability of peaks at longer latencies. There was no change in wave latency or reproducibility of MLAERs recorded during different sleep states. Waves Po and Na showed a significant decrease in latency with increasing stimulus intensity at term and/or 6 weeks of age. This was not evident for the remainder of the waveform. Waves Po, Na, Pa, Nb, Pb and Nc exhibited significant decreases in latency with age, attaining values indistinguishable from adults by 7 months of age.

  4. Rate and adaptation effects on the auditory evoked brainstem response in human newborns and adults.

    Science.gov (United States)

    Lasky, R E

    1997-09-01

    Auditory evoked brainstem response (ABR) latencies increased and amplitudes decreased with increasing stimulus repetition rate for human newborns and adults. The wave V latency increases were larger for newborns than adults. The wave V amplitude decreases were smaller for newborns than adults. These differences could not be explained by developmental differences in frequency responsivity. The transition from the unadapted to the fully adapted response was less rapid in newborns than adults at short (= 10 ms) inter stimulus intervals (ISIs). At longer ISIs (= 20 ms) there were no developmental differences in the transition to the fully adapted response. The newborn transition occurred in a two stage process. The rapid initial stage observed in adults and newborns was complete by about 40 ms. A second slower stage was observed only in newborns although it has been observed in adults in other studies (Weatherby and Hecox, 1982; Lightfoot, 1991; Lasky et al., 1996). These effects were replicated at different stimulus intensities. After the termination of stimulation the return to the wave V unadapted response took nearly 500 ms in newborns. Neither the newborn nor the adult data can be explained by forward masking of one click on the next click. These results indicate human developmental differences in adaptation to repetitive auditory stimulation at the level of the brainstem.

  5. Temporal resolution in the hearing system and auditory evoked potentials

    DEFF Research Database (Denmark)

    Miller, Lee; Beedholm, Kristian

    2008-01-01

    3pAB5. Temporal resolution in the hearing system and auditory evoked potentials. Kristian Beedholm Institute of Biology,University of Southern Denmark, Campusvej 55, 5230 Odense M, Denmark, beedholm@mail.dk, Lee A. Miller Institute of Biology,University of Southern Denmark, Campusvej 55, 5230...... Odense M, Denmark, lee@biology.sdu.dkA popular type of investigation with auditory evoked potentials AEP consists of mapping the dependency of the envelope followingresponse to the AM frequency. This results in what is called the modulation rate transfer function MRTF. The physiologicalinterpretation...... of the MRTF is not straight forward, but is often used as a measure of the ability of the auditory system to encodetemporal changes. It is, however, shown here that the MRTF must depend on the waveform of the click-evoked AEP ceAEP, whichdoes not relate directly to temporal resolution. The theoretical...

  6. Neuronal Rac1 is required for learning-evoked neurogenesis

    DEFF Research Database (Denmark)

    Haditsch, Ursula; Anderson, Matthew P; Freewoman, Julia

    2013-01-01

    neurons for normal synaptic plasticity in vivo, and here we show that selective loss of neuronal Rac1 also impairs the learning-evoked increase in neurogenesis in the adult mouse hippocampus. Earlier work has indicated that experience elevates the abundance of adult-born neurons in the hippocampus...... primarily by enhancing the survival of neurons produced just before the learning event. Loss of Rac1 in mature projection neurons did reduce learning-evoked neurogenesis but, contrary to our expectations, these effects were not mediated by altering the survival of young neurons in the hippocampus. Instead......, loss of neuronal Rac1 activation selectively impaired a learning-evoked increase in the proliferation and accumulation of neural precursors generated during the learning event itself. This indicates that experience-induced alterations in neurogenesis can be mechanistically resolved into two effects: (1...

  7. The effects of curiosity-evoking events on activity enjoyment.

    Science.gov (United States)

    Isikman, Elif; MacInnis, Deborah J; Ülkümen, Gülden; Cavanaugh, Lisa A

    2016-09-01

    Whereas prior literature has studied the positive effects of curiosity-evoking events that are integral to focal activities, we explore whether and how a curiosity-evoking event that is incidental to a focal activity induces negative outcomes for enjoyment. Four experiments and 1 field study demonstrate that curiosity about an event that is incidental to an activity in which individuals are engaged, significantly affects enjoyment of a concurrent activity. The reason why is that curiosity diverts attention away from the concurrent activity and focuses attention on the curiosity-evoking event. Thus, curiosity regarding an incidental event decreases enjoyment of a positive focal activity but increases enjoyment of a negative focal activity.

  8. Electrosurgical Plasma Discharges

    Science.gov (United States)

    Stalder, K. R.; Woloszko, J.

    2002-10-01

    Electrosurgical instruments employing plasmas to volumetrically ablate tissue are now enjoying widespread use in medical applications. We have studied several commercially available instruments in which luminous plasma discharges are formed near electrodes immersed in saline solutions when sufficiently large amplitude bipolar voltage waveforms are applied. Different aqueous salt solutions have been investigated, including isotonic NaCl solution as well as solutions of KCl, and BaCl_2. With strong driving voltage applied, a vapor layer is formed as well as visible and UV optical emissions. Spectroscopic measurements reveal the predominant emissions are from the low ionization potential salt species, but significant emissions from electron impact dissociated water fragments such as OH and H-atoms also are observed. The emissions also coincide with negative bias on the active electrode. These optical emissions are consistent with an electron density of about 10^12cm-3 and an electron temperature of about 4 eV. Experimental results and model calculations of the vapor layer formation process and plasma formation in the high-field region will be discussed.

  9. YANGTZE DISCHARGE MEMORY

    Institute of Scientific and Technical Information of China (English)

    Klaus Fraedrich; Xiuhua Zhu

    2009-01-01

    We present a review on studies focusing on memories in hydrological time series in the Yangtze Basin based on observational and reconstructed historical data.Memory appears as scaling of power spectra,S(f)~f-β,with 0 <β≤ 1.The presence of scaling is noteworthy in daily river discharge time series:1)from weeks to a couple of years,power spectra follow flicker noise,that is β≈ 1;2)beyond years,spectral scaling appraaclTes β≈0.3.In historical time series of floods and draughts,power spectra also shows scaling with β≈ 0.38 ~0.52.Furthermore,a 70-year peak is detected in historical maritime events series,which also appears in other past climate indicators.Presence of memory in these hydrological time series implies clustering of extremes and scaling of their recurrence times,therefore,probabilistic forecast potential for extremes can be derived.On the other hand,although several physical processes,for example,soil moisture storage and high intermittency of precipitation,have been suggested to be the possible candidates contributing to the presence of long term memory,they remain open for future research.

  10. Modelling Discharge Inception in Thunderstorms

    NARCIS (Netherlands)

    Rutjes, Casper; Dubinova, Anna; Ebert, Ute; Buitink, Stijn; Scholten, Olaf; Trinh, Gia Thi Ngoc

    2015-01-01

    The electric fields in thunderstorms can exceed the breakdown value locally near hydrometeors. But are fields high enough and the regions large enough to initiate a streamer discharge? And where would a sufficient density of free electrons come from to start the discharge in the humid air that rapid

  11. [Redesigning the hospital discharge process].

    Science.gov (United States)

    Martínez-Ramos, M; Flores-Pardo, E; Uris-Sellés, J

    2016-01-01

    The aim of this article is to show that the redesign and planning process of hospital discharge advances the departure time of the patient from a hospital environment. Quasi-experimental study conducted from January 2011 to April 2013, in a local hospital. The cases analysed were from medical and surgical nursing units. The process was redesigned to coordinate all the professionals involved in the process. The hospital discharge improvement process improvement was carried out by forming a working group, the analysis of retrospective data, identifying areas for improvement, and its redesign. The dependent variable was the time of patient administrative discharge. The sample was classified as pre-intervention, inter-intervention, and post-intervention, depending on the time point of the study. The final sample included 14,788 patients after applying the inclusion and exclusion criteria. The mean discharge release time decreased significantly by 50 min between pre-intervention and post-intervention periods. The release time in patients with planned discharge was one hour and 25 min less than in patients with unplanned discharge. Process redesign is a useful strategy to improve the process of hospital discharge. Besides planning the discharge, it is shown that the patient leaving the hospital before 12 midday is a key factor. Copyright © 2015 SECA. Published by Elsevier Espana. All rights reserved.

  12. [Determination of irreversibility of clinical brain death. Electroencephalography and evoked potentials].

    Science.gov (United States)

    Buchner, H; Ferbert, A

    2016-02-01

    Principally, in the fourth update of the rules for the procedure to finally determine the irreversible cessation of function of the cerebrum, the cerebellum and the brainstem, the importance of an electroencephalogram (EEG), somatosensory evoked potentials (SEP) and brainstem auditory evoked potentials (BAEP) are confirmed. This paper presents the reliability and validity of the electrophysiological diagnosis, discusses the amendments in the fourth version of the guidelines and introduces the practical application, problems and sources of error.An EEG is the best established supplementary diagnostic method for determining the irreversibility of clinical brain death syndrome. It should be noted that residual brain activity can often persist for many hours after the onset of brain death syndrome, particularly in patients with primary brainstem lesions. The derivation and analysis of an EEG requires a high level of expertise to be able to safely distinguish artefacts from primary brain activity. The registration of EEGs to demonstrate the irreversibility of clinical brain death syndrome is extremely time consuming.The BAEPs can only be used to confirm the irreversibility of brain death syndrome in serial examinations or in the rare cases of a sustained wave I or sustained waves I and II. Very often, an investigation cannot be reliably performed because of existing sound conduction disturbances or failure of all potentials even before the onset of clinical brain death syndrome. This explains why BAEPs are only used in exceptional cases.The SEPs of the median nerve can be very reliably derived, are technically simple and with few sources of error. A serial investigation is not required and the time needed for examination is short. For these reasons SEPs are given preference over EEGs and BAEPs for establishing the irreversibility of clinical brain death syndrome.

  13. Plasma waves

    CERN Document Server

    Swanson, DG

    1989-01-01

    Plasma Waves discusses the basic development and equations for the many aspects of plasma waves. The book is organized into two major parts, examining both linear and nonlinear plasma waves in the eight chapters it encompasses. After briefly discussing the properties and applications of plasma wave, the book goes on examining the wave types in a cold, magnetized plasma and the general forms of the dispersion relation that characterize the waves and label the various types of solutions. Chapters 3 and 4 analyze the acoustic phenomena through the fluid model of plasma and the kinetic effects. Th

  14. Electrode position and the multi-focal visual-evoked potential: role in objective visual field assessment.

    Science.gov (United States)

    Klistorner, A I; Graham, S L; Grigg, J R; Billson, F A

    1998-05-01

    To improve the performance of visual-evoked potentials (VEP) in the assessment of the human visual field, the multi-focal cortically scaled pattern VEP was recorded up to 250 of eccentricity in normal subjects. Monopolar and varying bipolar electrode positions were used. The monopolar response was strongly biased towards the lower hemifield. Bipolar leads straddling the inion (2 cm above and below) achieved approximately equal signals from the upper and lower visual field. Division into sectors of similar wave-form augments the analysis compared with summed full-field responses. With this technique, the multi-focal VEP can be used to objectively assess the visual field.

  15. The practice of terminal discharge.

    Science.gov (United States)

    Radha Krishna, Lalit Kumar; Murugam, Vengadasalam; Quah, Daniel Song Chiek

    2017-01-01

    'Terminal discharges' are carried out in Singapore for patients who wish to die at home. However, if due diligence is not exercised, parallels may be drawn with euthanasia. We present a theoretical discussion beginning with the definition of terminal discharges and the reasons why they are carried out in Singapore. By considering the intention behind terminal discharges and utilising a multidisciplinary team to deliberate on the clinical, social and ethical intricacies with a patient- and context-specific approach, euthanasia is avoided. It is hoped that this will provide a platform for professionals in palliative medicine to negotiate challenging issues when arranging a terminal discharge, so as to avoid the pitfall of committing euthanasia in a country such as Singapore where euthanasia is illegal. It is hoped that a set of guidelines for terminal discharges may someday be realised to assist professionals in Singapore and around the world.

  16. [Speech evoked auditory brainstem response and cognitive disorders].

    Science.gov (United States)

    Zhou, M; Wang, N Y

    2016-12-07

    Speech evoked auditory brainstem response(s-ABR)is evoked by compound syllable, and those stimulus are similar to the daily language which convey both semantic information and non-semantic information. Speech coding program can take place at brainstem. As a new method, s-ABR may reveal the mystery of speech coding program. Many tests have proved that s-ABR is somehow related to cognitive ability. We mainly illustrated the possibility of grading the cognitive ability using s-ABR, the abnormal test result from those cognitive disorders, and the family factors that contribute to cognitive disorder.

  17. Vestibular-dependent inter-stimulus interval effects on sound evoked potentials of central origin.

    Science.gov (United States)

    Todd, N P M; Govender, S; Colebatch, J G

    2016-11-01

    Todd et al. (2014ab) have recently demonstrated the presence of vestibular-dependent contributions to auditory evoked potentials (AEPs) when passing through the vestibular threshold as determined by vestibular evoked myogenic potentials (VEMPs), including a particular deflection labeled as an N42/P52 prior to the long-latency AEPs N1 and P2. In this paper we report the results of an experiment to determine the effect of inter-stimulus interval (ISI) and regularity on potentials recorded above and below VEMP threshold. Five healthy, right-handed subjects were recruited and evoked potentials were recorded to binaurally presented sound stimulation, above and below vestibular threshold, at seven stimulus rates with ISIs of 212, 300, 424, 600, 848, 1200 and 1696 ms. The inner five intervals, i.e. 300, 424, 600, 848, 1200 ms, were presented twice in both regular and irregular conditions. ANOVA on the global field power (GFP) were conducted for each of four waves, N42, P52, N1 and P2 with factors of intensity, ISI and regularity. Both N42 and P52 waves showed significant ANOVA effects of intensity but no other main effects or interactions. In contrast both N1 and P2 showed additional effects of ISI, as well as intensity, and evidence of non-linear interactions between ISI and intensity. A source analysis was carried out consistent with prior work suggesting that when above vestibular threshold, in addition to bilateral superior temporal cortex, ocular, cerebellar and cingulate sources are recruited. Further statistical analysis of the source currents indicated that the origin of the interactions with intensity may be the ISI sensitivity of the vestibular-dependent sources. This in turn may reflect a specific vestibular preference for stimulus rates associated with locomotion, i.e. rates close to 2 Hz, or ISIs close to 500 ms, where saccular afferents show increased gain and the corresponding reflexes are most sensitive.

  18. Origin of facilitation of motor-evoked potentials after paired magnetic stimulation: direct recording of epidural activity in conscious humans.

    Science.gov (United States)

    Di Lazzaro, V; Pilato, F; Oliviero, A; Dileone, M; Saturno, E; Mazzone, P; Insola, A; Profice, P; Ranieri, F; Capone, F; Tonali, P A; Rothwell, J C

    2006-10-01

    A magnetic transcranial conditioning stimulus given over the motor cortex at intensities below active threshold for obtaining motor-evoked potentials (MEPs) facilitates EMG responses evoked at rest in hand muscles by a suprathreshold magnetic stimulus given 10-25 ms later. This is known as intracortical facilitation (ICF). We recorded descending volleys produced by single and paired magnetic motor cortex stimulation through high cervical epidural electrodes implanted for pain relief in six conscious patients. At interstimulus intervals (ISIs) of 10 and 15 ms, although MEP was facilitated, there was no change in the amplitude or number of descending volleys. An additional I wave sometimes was observed at 25 ms ISI. In one subject, we also evaluated the effects of reversing the direction of the induced current in the brain. At 10 ms ISI, the facilitation of the MEPs disappeared and was replaced by slight suppression; at 2 ms ISI, there was a pronounced facilitation of epidural volleys. Subsequent experiments on healthy subjects showed that a conditioning stimulus capable of producing ICF of MEPs had no effect on the EMG response evoked by transmastoidal electrical stimulation of corticospinal tract. We conclude that ICF occurs because either 1) the conditioning stimulus has a (thus far undetected) effect on spinal cord excitability that increases its response to the same amplitude test volley or 2) that it can alter the composition (but not the amplitude) of the descending volleys set up by the test stimulus such that a larger proportion of the activity is destined for the target muscle.

  19. Preliminary Investigation of a Dielectric Barrier Discharge Lamp in Open Air at Atmospheric Pressure

    Institute of Scientific and Technical Information of China (English)

    LIU Feng; WANG Wei-Wei; CHANG Xi-Jiang; LIANG Rong-Qing

    2011-01-01

    @@ A dielectric barrier discharge (DBD) lamp is investigated by using sinusoidal power with a 10 kHz frequency in open air at atmospheric pressure.With increasing applied voltages, the different discharge phenomena appear.At relatively low voltages, the discharge states are general stochastic filamentary discharges with weak light.However, at relatively high voltages, the walls of quartz tubes are heated sharply by plasma, and then the dazzling light is emitted very quickly to form the DBD Lamp, corresponding to the low maintaining voltage that is lower than the ignited voltage.The discharge state or mode of the DBD lamp that corresponds to the glow discharge is deduced according to the wave form of the circuit current, which is evidently different from the filamentary discharges.Under these conditions, the spectrum of the DBD lamp is continuous in the range 400-932nm, which is scanned in the range 300-932nm.It is also shown that there is another discharge state or mode that is different from the traditional filamentary discharges.Therefore, it is concluded that the discharge state or mode of the DBD lamp is a glow discharge.

  20. Simulation of Thermal and Chemical Relaxation in a Post-Discharge Air Corona Reactor

    CERN Document Server

    Meziane, M; Ducasse, O; Yousfi, M

    2016-01-01

    In a DC point-to-plane corona discharge reactor, the mono filamentary streamers cross the inter electrode gap with a natural repetition frequency of some tens of kHz. The discharge phase (including the primary and the secondary streamers development) lasts only some hundred of nanoseconds while the post-discharge phases occurring between two successive discharge phases last some tens of microseconds. From the point of view of chemical activation, the discharge phases create radical and excited species located inside the very thin discharge filaments while during the post-discharge phases these radical and excited species induce a chemical kinetics that diffuse in a part of the reactor volume. From the point of view of hydrodynamics activation, the discharge phases induce thermal shock waves and the storage of vibrational energy which relaxes into thermal form only during the post-discharge phase. Furthermore, the glow corona discharges that persist during the post-discharge phases induce the so called electri...

  1. Heat Waves

    Science.gov (United States)

    Heat Waves Dangers we face during periods of very high temperatures include: Heat cramps: These are muscular pains and ... having trouble with the heat. If a heat wave is predicted or happening… - Slow down. Avoid strenuous ...

  2. Wave Star

    DEFF Research Database (Denmark)

    Kramer, Morten; Brorsen, Michael; Frigaard, Peter

    Denne rapport beskriver numeriske beregninger af forskellige flydergeometrier for bølgeenergianlæget Wave Star.......Denne rapport beskriver numeriske beregninger af forskellige flydergeometrier for bølgeenergianlæget Wave Star....

  3. Recording visual evoked potentials and auditory evoked P300 at 9.4T static magnetic field.

    Science.gov (United States)

    Arrubla, Jorge; Neuner, Irene; Hahn, David; Boers, Frank; Shah, N Jon

    2013-01-01

    Simultaneous recording of electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) has shown a number of advantages that make this multimodal technique superior to fMRI alone. The feasibility of recording EEG at ultra-high static magnetic field up to 9.4 T was recently demonstrated and promises to be implemented soon in fMRI studies at ultra high magnetic fields. Recording visual evoked potentials are expected to be amongst the most simple for simultaneous EEG/fMRI at ultra-high magnetic field due to the easy assessment of the visual cortex. Auditory evoked P300 measurements are of interest since it is believed that they represent the earliest stage of cognitive processing. In this study, we investigate the feasibility of recording visual evoked potentials and auditory evoked P300 in a 9.4 T static magnetic field. For this purpose, EEG data were recorded from 26 healthy volunteers inside a 9.4 T MR scanner using a 32-channel MR compatible EEG system. Visual stimulation and auditory oddball paradigm were presented in order to elicit evoked related potentials (ERP). Recordings made outside the scanner were performed using the same stimuli and EEG system for comparison purposes. We were able to retrieve visual P100 and auditory P300 evoked potentials at 9.4 T static magnetic field after correction of the ballistocardiogram artefact using independent component analysis. The latencies of the ERPs recorded at 9.4 T were not different from those recorded at 0 T. The amplitudes of ERPs were higher at 9.4 T when compared to recordings at 0 T. Nevertheless, it seems that the increased amplitudes of the ERPs are due to the effect of the ultra-high field on the EEG recording system rather than alteration in the intrinsic processes that generate the electrophysiological responses.

  4. Recording visual evoked potentials and auditory evoked P300 at 9.4T static magnetic field.

    Directory of Open Access Journals (Sweden)

    Jorge Arrubla

    Full Text Available Simultaneous recording of electroencephalography (EEG and functional magnetic resonance imaging (fMRI has shown a number of advantages that make this multimodal technique superior to fMRI alone. The feasibility of recording EEG at ultra-high static magnetic field up to 9.4 T was recently demonstrated and promises to be implemented soon in fMRI studies at ultra high magnetic fields. Recording visual evoked potentials are expected to be amongst the most simple for simultaneous EEG/fMRI at ultra-high magnetic field due to the easy assessment of the visual cortex. Auditory evoked P300 measurements are of interest since it is believed that they represent the earliest stage of cognitive processing. In this study, we investigate the feasibility of recording visual evoked potentials and auditory evoked P300 in a 9.4 T static magnetic field. For this purpose, EEG data were recorded from 26 healthy volunteers inside a 9.4 T MR scanner using a 32-channel MR compatible EEG system. Visual stimulation and auditory oddball paradigm were presented in order to elicit evoked related potentials (ERP. Recordings made outside the scanner were performed using the same stimuli and EEG system for comparison purposes. We were able to retrieve visual P100 and auditory P300 evoked potentials at 9.4 T static magnetic field after correction of the ballistocardiogram artefact using independent component analysis. The latencies of the ERPs recorded at 9.4 T were not different from those recorded at 0 T. The amplitudes of ERPs were higher at 9.4 T when compared to recordings at 0 T. Nevertheless, it seems that the increased amplitudes of the ERPs are due to the effect of the ultra-high field on the EEG recording system rather than alteration in the intrinsic processes that generate the electrophysiological responses.

  5. Wave Dragon

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter; Sørensen, H. C.

    1998-01-01

    This paper concerns with the development of the wave energy converter (WEC) Wave Dragon. This WEC is based on the overtopping principle. An overview of the performed research done concerning the Wave Dragon over the past years is given, and the results of one of the more comprehensive studies......, concerning a hydraulic evaluation and optimisation of the geometry of the Wave Dragon, is presented. Furthermore, the plans for the future development projects are sketched....

  6. Electromagnetic Waves

    DEFF Research Database (Denmark)

    This book is dedicated to various aspects of electromagnetic wave theory and its applications in science and technology. The covered topics include the fundamental physics of electromagnetic waves, theory of electromagnetic wave propagation and scattering, methods of computational analysis......, material characterization, electromagnetic properties of plasma, analysis and applications of periodic structures and waveguide components, etc....

  7. Wave phenomena

    CERN Document Server

    Towne, Dudley H

    1988-01-01

    This excellent undergraduate-level text emphasizes optics and acoustics, covering inductive derivation of the equation for transverse waves on a string, acoustic plane waves, boundary-value problems, polarization, three-dimensional waves and more. With numerous problems (solutions for about half). ""The material is superbly chosen and brilliantly written"" - Physics Today. Problems. Appendices.

  8. Discharge Planning in Chronic Conditions

    Science.gov (United States)

    McMartin, K

    2013-01-01

    Background Chronically ill people experience frequent changes in health status accompanied by multiple transitions between care settings and care providers. Discharge planning provides support services, follow-up activities, and other interventions that span pre-hospital discharge to post-hospital settings. Objective To determine if discharge planning is effective at reducing health resource utilization and improving patient outcomes compared with standard care alone. Data Sources A standard systematic literature search was conducted for studies published from January 1, 2004, until December 13, 2011. Review Methods Reports, randomized controlled trials, systematic reviews, and meta-analyses with 1 month or more of follow-up and limited to specified chronic conditions were examined. Outcomes included mortality/survival, readmissions and emergency department (ED) visits, hospital length of stay (LOS), health-related quality of life (HRQOL), and patient satisfaction. Results One meta-analysis compared individualized discharge planning to usual care and found a significant reduction in readmissions favouring individualized discharge planning. A second meta-analysis compared comprehensive discharge planning with postdischarge support to usual care. There was a significant reduction in readmissions favouring discharge planning with postdischarge support. However, there was significant statistical heterogeneity. For both meta-analyses there was a nonsignificant reduction in mortality between the study arms. Limitations There was difficulty in distinguishing the relative contribution of each element within the terms “discharge planning” and “postdischarge support.” For most studies, “usual care” was not explicitly described. Conclusions Compared with usual care, there was moderate quality evidence that individualized discharge planning is more effective at reducing readmissions or hospital LOS but not mortality, and very low quality evidence that it is more

  9. NPDES (National Pollution Discharge & Elimination System) Minor Dischargers

    Data.gov (United States)

    U.S. Environmental Protection Agency — As authorized by the Clean Water Act, the National Pollutant Discharge Elimination System (NPDES) permit program controls water pollution by regulating point sources...

  10. Value of transcranial motor evoked potentials during spinal operations

    Institute of Scientific and Technical Information of China (English)

    2009-01-01

    @@ To the Editor: We read the interesting recent article by Ding et al1 concerning the value of somatosensory evoked potentials (SEPs) in the diagnosis and prognosis of cervical spondylotic myelopathy, as well as the usefulness of monitoring intraoperative potentials in terms of safety and predictive factors.

  11. Evaluation of Evoked Potentials to Dyadic Tones after Cochlear Implantation

    Science.gov (United States)

    Sandmann, Pascale; Eichele, Tom; Buechler, Michael; Debener, Stefan; Jancke, Lutz; Dillier, Norbert; Hugdahl, Kenneth; Meyer, Martin

    2009-01-01

    Auditory evoked potentials are tools widely used to assess auditory cortex functions in clinical context. However, in cochlear implant users, electrophysiological measures are challenging due to implant-created artefacts in the EEG. Here, we used independent component analysis to reduce cochlear implant-related artefacts in event-related EEGs of…

  12. Recording and assessment of evoked potentials with electrode arrays.

    Science.gov (United States)

    Miljković, N; Malešević, N; Kojić, V; Bijelić, G; Keller, T; Popović, D B

    2015-09-01

    In order to optimize procedure for the assessment of evoked potentials and to provide visualization of the flow of action potentials along the motor systems, we introduced array electrodes for stimulation and recording and developed software for the analysis of the recordings. The system uses a stimulator connected to an electrode array for the generation of evoked potentials, an electrode array connected to the amplifier, A/D converter and computer for the recording of evoked potentials, and a dedicated software application. The method has been tested for the assessment of the H-reflex on the triceps surae muscle in six healthy humans. The electrode array with 16 pads was positioned over the posterior aspect of the thigh, while the recording electrode array with 16 pads was positioned over the triceps surae muscle. The stimulator activated all the pads of the stimulation electrode array asynchronously, while the signals were recorded continuously at all the recording sites. The results are topography maps (spatial distribution of evoked potentials) and matrices (spatial visualization of nerve excitability). The software allows the automatic selection of the lowest stimulation intensity to achieve maximal H-reflex amplitude and selection of the recording/stimulation pads according to predefined criteria. The analysis of results shows that the method provides rich information compared with the conventional recording of the H-reflex with regard the spatial distribution.

  13. Cortical Auditory Evoked Potentials in Unsuccessful Cochlear Implant Users

    Science.gov (United States)

    Munivrana, Boska; Mildner, Vesna

    2013-01-01

    In some cochlear implant users, success is not achieved in spite of optimal clinical factors (including age at implantation, duration of rehabilitation and post-implant hearing level), which may be attributed to disorders at higher levels of the auditory pathway. We used cortical auditory evoked potentials to investigate the ability to perceive…

  14. SOMATOSENSORY EVOKED-POTENTIALS IN CEREBRAL ANEURYSM SURGERY

    NARCIS (Netherlands)

    BUCHTHAL, A; BELOPAVLOVIC, M

    1992-01-01

    Monitoring of median nerve somatosensory evoked potentials (SSEP) during surgery for a basilar artery aneurysm under moderate hypothermia revealed an unexpected loss of the first cortical peak. This was due to compression of the middle cerebral artery under the retractor during the surgical approach

  15. Cortical Variability in the Sensory-Evoked Response in Autism

    Science.gov (United States)

    Haigh, Sarah M.; Heeger, David J.; Dinstein, Ilan; Minshew, Nancy; Behrmann, Marlene

    2015-01-01

    Previous findings have shown that individuals with autism spectrum disorder (ASD) evince greater intra-individual variability (IIV) in their sensory-evoked fMRI responses compared to typical control participants. We explore the robustness of this finding with a new sample of high-functioning adults with autism. Participants were presented with…

  16. Asymmetric vestibular evoked myogenic potentials in unilateral Meniere patients

    NARCIS (Netherlands)

    Kingma, C. M.; Wit, H. P.

    2011-01-01

    Vestibular evoked myogenic potentials (VEMPs) were measured in 22 unilateral MeniSre patients with monaural and binaural stimulation with 250 and 500 Hz tone bursts. For all measurement situations significantly lower VEMP amplitudes were on average measured at the affected side compared to the unaff

  17. Analysis and Treatment of Problem Behavior Evoked by Music

    Science.gov (United States)

    Buckley, Scott D.; Newchok, Debra K.

    2006-01-01

    The present study investigated the effects of differential negative reinforcement of other behavior (DNRO) on problem behavior evoked by music in a 7-year-old child with pervasive developmental disorder. Following an auditory stimulus assessment, DNRO was used to reduce problem behavior to near-zero levels. Results are discussed in terms of…

  18. Cortical Auditory Evoked Potentials in Unsuccessful Cochlear Implant Users

    Science.gov (United States)

    Munivrana, Boska; Mildner, Vesna

    2013-01-01

    In some cochlear implant users, success is not achieved in spite of optimal clinical factors (including age at implantation, duration of rehabilitation and post-implant hearing level), which may be attributed to disorders at higher levels of the auditory pathway. We used cortical auditory evoked potentials to investigate the ability to perceive…

  19. Thermal grill conditioning: Effect on contact heat evoked potentials

    Science.gov (United States)

    Jutzeler, Catherine R.; Warner, Freda M.; Wanek, Johann; Curt, Armin; Kramer, John L. K.

    2017-01-01

    The ‘thermal grill illusion’ (TGI) is a unique cutaneous sensation of unpleasantness, induced through the application of interlacing warm and cool stimuli. While previous studies have investigated optimal parameters and subject characteristics to evoke the illusion, our aim was to examine the modulating effect as a conditioning stimulus. A total of 28 healthy control individuals underwent three testing sessions on separate days. Briefly, 15 contact heat stimuli were delivered to the right hand dorsum, while the left palmar side of the hand was being conditioned with either neutral (32 °C), cool (20 °C), warm (40 °C), or TGI (20/40 °C). Rating of perception (numeric rating scale: 0–10) and evoked potentials (i.e., N1 and N2P2 potentials) to noxious contact heat stimuli were assessed. While cool and warm conditioning decreased cortical responses to noxious heat, TGI conditioning increased evoked potential amplitude (N1 and N2P2). In line with other modalities of unpleasant conditioning (e.g., sound, visual, and olfactory stimulation), cortical and possibly sub-cortical modulation may underlie the facilitation of contact heat evoked potentials. PMID:28079118

  20. The computation of evoked heart rate and blood pressure

    NARCIS (Netherlands)

    Koers, G.; Mulder, L.J.M.; van der Veen, F.M.

    1999-01-01

    For many years psychophysiologists have been interested in stimulus related changes in heart rate and blood pressure. To represent these evoked heart rate and blood pressure patterns, heart rate and blood pressure data have to be transformed into equidistant time series. This paper presents an

  1. Multichannel recording of tibial-nerve somatosensory evoked potentials

    NARCIS (Netherlands)

    de Wassenberg, W. J. G. van; Kruizinga, W. J.; van der Hoeven, J. H.; Leenders, K. L.; Maurits, N. M.

    2008-01-01

    Study aims. -The topography of the peaks of tibial.-nerve somatosensory evoked potential (SEP) varies among healthy subjects, most likely because of differences in position and orientation of their cortical generator(s). Therefore, amplitude estimation with a standard one- or two-channel derivation

  2. HIGH ENERGY GASEOUS DISCHARGE DEVICES

    Science.gov (United States)

    Josephson, V.

    1960-02-16

    The high-energy electrical discharge device described comprises an envelope, a pair of main discharge electrodes supported in opposition in the envelope, and a metallic shell symmetrically disposed around and spaced from the discharge path between the electrodes. The metallic shell comprises a first element of spaced helical turns of metallic material and a second element of spaced helical turns of methllic material insulatedly supported in superposition outside the first element and with the turns overlapping the gap between the turns of the first element.

  3. An introduction to gas discharges

    CERN Document Server

    Howatson, A M

    2013-01-01

    An Introduction to Gas Discharges: Second Edition aims to provide a compact introduction to the subject of gas discharges, which continues to make both scientific and industrial progress. In this second edition, the author has made minor corrections, rewritten and expanded some sections, used SI units and modernized notions, in hopes of making the book more up to date. Included in the book is a short history of the subject, an introduction that enumerates the types of gas discharges, the fundamental processes, and then moves on to the more specific areas such as the breakdown, the self-sustai

  4. Snowfall induced by corona discharge

    CERN Document Server

    Ju, Jingjing; Li, Ruxin; Du, Shengzhe; Sun, Haiyi; Liu, Yonghong; Tian, Ye; Bai, Yafeng; Liu, Yaoxiang; Chen, Na; Wang, Jingwei; Wang, Cheng; Liu, Jiansheng; Chin, S L; Xu, Zhizhan

    2016-01-01

    We demonstrated for the first time the condensation and precipitation (or snowfall) induced by a corona discharge inside a cloud chamber. Ionic wind was found to have played a more significant role than ions as extra Cloud Condensation Nuclei (CCN). 2.25 g of net snow enhancement was measured after applying a 30 kV corona discharge for 25 min. In comparison with another newly emerging femtosecond laser filamentation method, the snow precipitation induced by the corona discharge has about 4 orders of magnitude higher wall-plug efficiency under similar conditions.

  5. Closed cycle electric discharge laser design investigation

    Science.gov (United States)

    Baily, P. K.; Smith, R. C.

    1978-01-01

    Closed cycle CO2 and CO electric discharge lasers were studied. An analytical investigation assessed scale-up parameters and design features for CO2, closed cycle, continuous wave, unstable resonator, electric discharge lasing systems operating in space and airborne environments. A space based CO system was also examined. The program objectives were the conceptual designs of six CO2 systems and one CO system. Three airborne CO2 designs, with one, five, and ten megawatt outputs, were produced. These designs were based upon five minute run times. Three space based CO2 designs, with the same output levels, were also produced, but based upon one year run times. In addition, a conceptual design for a one megawatt space based CO laser system was also produced. These designs include the flow loop, compressor, and heat exchanger, as well as the laser cavity itself. The designs resulted in a laser loop weight for the space based five megawatt system that is within the space shuttle capacity. For the one megawatt systems, the estimated weight of the entire system including laser loop, solar power generator, and heat radiator is less than the shuttle capacity.

  6. Underwater electrical discharge in plate to plate configuration

    Science.gov (United States)

    Stelmashuk, Vitaliy

    2016-09-01

    Two main configurations of high voltage electrodes submersed in water have been used for an electrical discharge generation: pin to pin and pin to plate. An electrical breakdown between plate electrodes is generally difficult to reproduce, because there is a uniform and weak electric field. One major advantage of using plate electrodes is their greater ``wear hardness'' to high-energy discharges. The plate electrodes can withstand extremely high energy deposition at which the pin electrode is quickly destroyed. The electrical discharge between plate electrodes can be initiated by creating an inhomogeneity in the electrical field. Two methods of discharge initiation between plate electrodes are proposed for this aim: 1) focusing of a shock wave in the interelectrode region; 2) a bubble injection into the electrode gap. The shock wave creates favourable conditions for the electrical breakdown between the two plate electrodes: it causes that numerous microbubbles of dissolved air start to grow and serve as locations for streamer initiation. In the second method the gas bubble is injected from the one of the electrodes, which has a gas inlet hole on the lateral face for this purpose. A ``volcano'' like morphology of positive streamers are observed in the experiments with weak electric field. The authors are grateful to MEYS grant INGO LG 15013.

  7. Dynamics of near-surface electric discharges and mechanisms of their interaction with the airflow

    Science.gov (United States)

    Leonov, Sergey B.; Adamovich, Igor V.; Soloviev, Victor R.

    2016-12-01

    The main focus of the review is on dynamics and kinetics of near-surface discharge plasmas, such as surface dielectric barrier discharges sustained by AC and repetitively pulsed waveforms, pulsed DC discharges, and quasi-DC discharges, generated in quiescent air and in the airflow. A number of technical issues related to plasma flow control applications are discussed in detail, including discharge development via surface ionization waves, charge transport and accumulation on dielectric surface, discharge contraction, different types of flow perturbations generated by surface discharges, and effect of high-speed flow on discharge dynamics. In the first part of the manuscript, plasma morphology and results of electrical and optical emission spectroscopy measurements are discussed. Particular attention is paid to dynamics of surface charge accumulation and dissipation, both in diffuse discharges and during development of ionization instabilities resulting in discharge contraction. Contraction leads to significant increase of both the surface area of charge accumulation and the energy coupled to the plasma. The use of alternating polarity pulse waveforms accelerates contraction of surface dielectric barrier discharges and formation of filamentary plasmas. The second part discusses the interaction of discharge plasmas with quiescent air and the external airflow. Four major types of flow perturbations have been identified: (1) low-speed near-surface jets generated by electrohydrodynamic interaction (ion wind); (2) spanwise and streamwise vortices formed by both electrohydrodynamic and thermal effects; (3) weak shock waves produced by rapid heating in pulsed discharges on sub-microsecond time scale; and (4) near-surface localized stochastic perturbations, on sub-millisecond time, detected only recently. The mechanism of plasma-flow interaction remains not fully understood, especially in filamentary surface dielectric barrier discharges. Localized quasi-DC surface

  8. Measurement of the impulse produced by a pulsed surface discharge actuator in air

    Science.gov (United States)

    Elias, P. Q.; Castera, P.

    2013-09-01

    The pulsed surface discharge in atmospheric pressure air generates a shock wave, thereby transferring an impulse to the surrounding gas. The aim of this work is to measure this impulse, using implementation of a plasma actuator based on linear surface discharges of length up to 10 cm, and of linear energy in a range 0.1-0.5 J cm-1. The shock wave generated by the discharge is visualized using a pulsed schlieren system and the impulse is measured with a dedicated balance. These measurements are correlated with 1D numerical simulations of pulsed energy depositions in a perfect gas. Experiments show that the discharge generates a cylindrical shock wave that travels at sonic speed after a few tens of microseconds, and produces an impulse that varies from 1 to 4 mN s m-1 and scales linearly with the linear energy density. This linearity agrees with the numerical simulations when 9.5% of the energy dissipated in the discharge is assumed to heat the gas. Overall, to produce a time-averaged force similar to the one achieved by dielectric barrier discharge (DBD) actuators, 2 to 3 times more power is required. However, surface discharge actuators do not saturate, and thus can induce time-averaged forces one or two orders of magnitude above DBD when pulsed at several hundreds of hertz.

  9. Research on the Optical Properties of Transformers Partial Discharge Based on Different Discharge Models

    Directory of Open Access Journals (Sweden)

    Wei Bengang

    2016-01-01

    Full Text Available In this paper, the different types of discharge in transformer were simulated based on the real transformer fault model. The optical partial discharge detection system was established based on optical sensors which were capturing partial discharge accompanied by optical effects. In this research, surface discharge and suspended discharge defect model was pressurized to generate partial discharge signal. The results showed that: Partial discharge optical signals could effectively respond the production and development process of transformer partial discharge. It was able to assess discharge level also. When the discharge phenomenon stabilized, the phase of surface discharge mainly between 60°~150°and 240°~330°, the phase of suspended discharge mainly between 260°~320°. According to the phase characteristic of discharge pattern, the creeping discharge and suspended discharge phenomenon of transformer can be distinguished. It laid the foundation for the application of transformer optical partial discharge detection technology.

  10. Oblique dust density waves

    Science.gov (United States)

    Piel, Alexander; Arp, Oliver; Menzel, Kristoffer; Klindworth, Markus

    2007-11-01

    We report on experimental observations of dust density waves in a complex (dusty) plasma under microgravity. The plasma is produced in a radio-frequency parallel-plate discharge (argon, p=15Pa, U=65Vpp). Different sizes of dust particles were used (3.4 μm and 6.4μm diameter). The low-frequency (f 11Hz) dust density waves are naturally unstable modes, which are driven by the ion flow in the plasma. Surprisingly, the wave propagation direction is aligned with the ion flow direction in the bulk plasma but becomes oblique at the boundary of the dust cloud with an inclination of 60^o with respect to the plasma boundary. The experimental results are compared with a kinetic model in the electrostatic approximation [1] and a fluid model [2]. Moreover, the role of dust surface waves is discussed. [1] M. Rosenberg, J. Vac. Sci. Technol. A 14, 631 (1996) [2] A. Piel et al, Phys. Rev. Lett. 97, 205009 (2006)

  11. Regulation of epileptiform discharges in rat neocortex by HCN channels.

    Science.gov (United States)

    Albertson, Asher J; Williams, Sidney B; Hablitz, John J

    2013-10-01

    Hyperpolarization-activated, cyclic nucleotide-gated, nonspecific cation (HCN) channels have a well-characterized role in regulation of cellular excitability and network activity. The role of these channels in control of epileptiform discharges is less thoroughly understood. This is especially pertinent given the altered HCN channel expression in epilepsy. We hypothesized that inhibition of HCN channels would enhance bicuculline-induced epileptiform discharges. Whole cell recordings were obtained from layer (L)2/3 and L5 pyramidal neurons and L1 and L5 GABAergic interneurons. In the presence of bicuculline (10 μM), HCN channel inhibition with ZD 7288 (20 μM) significantly increased the magnitude (defined as area) of evoked epileptiform events in both L2/3 and L5 neurons. We recorded activity associated with epileptiform discharges in L1 and L5 interneurons to test the hypothesis that HCN channels regulate excitatory synaptic inputs differently in interneurons versus pyramidal neurons. HCN channel inhibition increased the magnitude of epileptiform events in both L1 and L5 interneurons. The increased magnitude of epileptiform events in both pyramidal cells and interneurons was due to an increase in network activity, since holding cells at depolarized potentials under voltage-clamp conditions to minimize HCN channel opening did not prevent enhancement in the presence of ZD 7288. In neurons recorded with ZD 7288-containing pipettes, bath application of the noninactivating inward cationic current (Ih) antagonist still produced increases in epileptiform responses. These results show that epileptiform discharges in disinhibited rat neocortex are modulated by HCN channels.

  12. The effects of notch filtering on electrically evoked myoelectric signals and associated motor unit index estimates

    Directory of Open Access Journals (Sweden)

    Li Xiaoyan

    2011-11-01

    Full Text Available Abstract Background Notch filtering is the most commonly used technique for suppression of power line and harmonic interference that often contaminate surface electromyogram (EMG signals. Notch filters are routinely included in EMG recording instrumentation, and are used very often during clinical recording sessions. The objective of this study was to quantitatively assess the effects of notch filtering on electrically evoked myoelectric signals and on the related motor unit index measurements. Methods The study was primarily based on an experimental comparison of M wave recordings and index estimates of motor unit number and size, with the notch filter function of the EMG machine (Sierra Wave EMG system, Cadwell Lab Inc, Kennewick, WA, USA turned on and off, respectively. The comparison was implemented in the first dorsal interosseous (FDI muscle from the dominant hand of 15 neurologically intact subjects and bilaterally in 15 hemiparetic stroke subjects. Results On average, for intact subjects, the maximum M wave amplitude and the motor unit number index (MUNIX estimate were reduced by approximately 22% and 18%, respectively, with application of the built-in notch filter function in the EMG machine. This trend held true when examining the paretic and contralateral muscles of the stroke subjects. With the notch filter on vs. off, across stroke subjects, we observed a significant decrease in both maximum M wave amplitude and MUNIX values in the paretic muscles, as compared with the contralateral muscles. However, similar reduction ratios were obtained for both maximum M wave amplitude and MUNIX estimate. Across muscles of both intact and stroke subjects, it was observed that notch filtering does not have significant effects on motor unit size index (MUSIX estimate. No significant difference was found in MUSIX values between the paretic and contralateral muscles of the stroke subjects. Conclusions The notch filter function built in the EMG

  13. Pulsed discharge production Ar* metastables

    Science.gov (United States)

    Han, Jiande; Heaven, Michael C.; Emmons, Daniel; Perram, Glen P.; Weeks, David E.; Bailey, William F.

    2016-03-01

    The production of relatively high densities of Ar* metastables (>1012 cm-3) in Ar/He mixtures, at total pressures close to 1 atm, is essential for the efficient operation of an optically pumped Ar* laser. We have used emission spectroscopy and diode laser absorption spectroscopy measurements to observe the production and decay of Ar* in a parallel plate pulsed discharge. With discharge pulses of 1 μs duration we find that metastable production is dominated by processes occurring within the first 100 ns of the gas break-down. Application of multiple, closely spaced discharge pulses yields insights concerning conditions that favor metastable production. This information has been combined with time-resolved measurements of voltage and current. The experimental results and preliminary modeling of the discharge kinetics are presented.

  14. Circle Points Discharge Tube Current Controller

    Institute of Scientific and Technical Information of China (English)

    Meng Jinjia; Meng Lisheng

    2005-01-01

    Circle points discharge tube current controller is a new type device to limit theoutput of high voltage discharge current. Circle points uniform corona discharge to form airionization current in the discharge tube. On the outside, even if the discharge electrode is sparkdischarging or the two discharge electrodes are short circuited, the air ionization current in the tuberemains within a stable range, and there is no spark discharge. In this case, when the dischargecurrent only increases slightly, the requirement to limited current is obtained. By installing thecontroller at a discharge pole with a small power but high voltage supply, we can realize the shiftbetween the continuous spark line discharge and corona discharge. This provides a new simpledevice for spark discharge research and is a supplement to the Townsend discharge experiment.

  15. Facilitating neuronal connectivity analysis of evoked responses by exposing local activity with principal component analysis preprocessing: simulation of evoked MEG.

    Science.gov (United States)

    Gao, Lin; Zhang, Tongsheng; Wang, Jue; Stephen, Julia

    2013-04-01

    When connectivity analysis is carried out for event related EEG and MEG, the presence of strong spatial correlations from spontaneous activity in background may mask the local neuronal evoked activity and lead to spurious connections. In this paper, we hypothesized PCA decomposition could be used to diminish the background activity and further improve the performance of connectivity analysis in event related experiments. The idea was tested using simulation, where we found that for the 306-channel Elekta Neuromag system, the first 4 PCs represent the dominant background activity, and the source connectivity pattern after preprocessing is consistent with the true connectivity pattern designed in the simulation. Improving signal to noise of the evoked responses by discarding the first few PCs demonstrates increased coherences at major physiological frequency bands when removing the first few PCs. Furthermore, the evoked information was maintained after PCA preprocessing. In conclusion, it is demonstrated that the first few PCs represent background activity, and PCA decomposition can be employed to remove it to expose the evoked activity for the channels under investigation. Therefore, PCA can be applied as a preprocessing approach to improve neuronal connectivity analysis for event related data.

  16. Frequency hopping millimeter wave reflectometer

    Science.gov (United States)

    Cupido, L.; Sánchez, J.; Estrada, T.

    2004-10-01

    Reflectometry techniques are employed to study density fluctuations in fusion plasmas either using one channel or two channels with slightly different frequencies, to probe simultaneously closely spaced plasma layers (for radial correlation studies). The present article describes a novel system with increasing measuring capability utilizing only one single frequency that can be hopped during the discharge. This broadband fast hopping mm-wave reflectometer (BFHR) has been developed for both ASDEX upgrade (Max Plank Institute-Garching-Germany) and TJ-II stellarator (CIEMAT-Spain). The BFHR incorporates frequency synthesizers at microwave frequencies multiplied into the millimeter-wave range and uses heterodyne detection for sensitive phase and amplitude measurements.

  17. Auditory evoked responses and learning and awareness during general anesthesia.

    Science.gov (United States)

    Ghoneim, M M; Block, R I; Dhanaraj, V J; Todd, M M; Choi, W W; Brown, C K

    2000-02-01

    There is a major distinction between conscious and unconscious learning. Monitoring the mid-latency auditory evoked responses (AER) has been proposed as a measure to ascertain the adequacy of the hypnotic state during surgery. In the present study, we investigated the presence of explicit and implicit memories after anesthesia and examined the relationships of such memories to the AER. We studied 180 patients scheduled for elective surgical procedures. After a thiopental induction, one of four anesthetics were studied: Opioid bolus: 7.5 microg x kg(-1) fentanyl, 70% N2O, with 2.5 microg x kg(-1) supplements as needed (n=100); Opioid infusion: Alfentanil 50 microg x kg(-1) bolus, 1-1.5 microg x kg(-1) x min(-1) infusion, 70% N2O (n=40); Isoflurane 0.3%: Fentanyl 1 microg x kg(-1), 70% N2O, isoflurane 0.3% expired (n=16); Isoflurane 0.7%: Fentanyl 1 microg x kg(-1), 70% N2O, isoflurane 0.7% expired (n=23). AER were recorded before anesthesia, 5 min after surgical incision and then every 30 min until the end of surgery. A tape of either the story of the "Three Little Pigs" or the "Wizard of Oz" was played continuously between the recordings. Explicit memory was assessed postoperatively by tests of recall and recognition, and implicit memory was assessed by the frequency of story-related free associations to target words from the stories, which were solicited twice during a structured interview. Six patients showed explicit recall of intraoperative events: All received the opioid bolus regimen. About 7% of patients reported dreaming during anesthesia. The incidence of picking the correct story that had been presented during anesthesia averaged 49%, i.e., very close to chance level. Overall, priming occurred only at the second association tests for the opioid bolus regimen, for which the frequency of an association to the presented story among those not giving an association to the control story was 26%, which was double the frequency (13%) of an association to the

  18. Study on the transition from filamentary discharge to diffuse discharge by using a dielectric barrier surface discharge device

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    Discharge characteristics have been investigated in different gases under different pressures using a dielectric barrier surface discharge device. Electrical measurements and optical emission spectroscopy are used to study the discharge,and the results obtained show that the discharges in atmospheric pressure helium and in low-pressure air are diffuse,while that in high-pressure air is filamentary. With decreasing pressure, the discharge in air can transit from filamentary to diffuse one. The results also indicate that corona discharge around the stripe electrode is important for the diffuse discharge. The spectral intensity of N2+ (391.4 nm) relative to N2 (337.1 nm) is measured during the transition from diffuse to filamentary discharge. It is shown that relative spectral intensity increases during the discharge transition. This phenomenon implies that the averaged electron energy in diffuse discharge is higher than that in the filamentary discharge.

  19. Classification of electrical discharges in DC Accelerators

    Energy Technology Data Exchange (ETDEWEB)

    Banerjee, Srutarshi, E-mail: sruban.stephens@gmail.com [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Deb, A.K. [Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302 (India); Rajan, Rehim N. [Accelerator and Pulse Power Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085 (India); Kishore, N.K. [Department of Electrical Engineering, Indian Institute of Technology Kharagpur, Kharagpur 721302 (India)

    2016-08-11

    Controlled electrical discharge aids in conditioning of the system while uncontrolled discharges damage its electronic components. DC Accelerator being a high voltage system is no exception. It is useful to classify electrical discharges according to the severity. Experimental prototypes of the accelerator discharges are developed. Photomultiplier Tubes (PMTs) are used to detect the signals from these discharges. Time and Frequency domain characteristics of the detected discharges are used to extract features. Machine Learning approaches like Fuzzy Logic, Neural Network and Least Squares Support Vector Machine (LSSVM) are employed to classify the discharges. This aids in detecting the severity of the discharges.

  20. Classification of electrical discharges in DC Accelerators

    Science.gov (United States)

    Banerjee, Srutarshi; Deb, A. K.; Rajan, Rehim N.; Kishore, N. K.

    2016-08-01

    Controlled electrical discharge aids in conditioning of the system while uncontrolled discharges damage its electronic components. DC Accelerator being a high voltage system is no exception. It is useful to classify electrical discharges according to the severity. Experimental prototypes of the accelerator discharges are developed. Photomultiplier Tubes (PMTs) are used to detect the signals from these discharges. Time and Frequency domain characteristics of the detected discharges are used to extract features. Machine Learning approaches like Fuzzy Logic, Neural Network and Least Squares Support Vector Machine (LSSVM) are employed to classify the discharges. This aids in detecting the severity of the discharges.

  1. Diffusion tensor imaging of the inferior colliculus and brainstem auditory-evoked potentials in preterm infants

    Energy Technology Data Exchange (ETDEWEB)

    Reiman, Milla; Lehtonen, Liisa; Lapinleimu, Helena [Turku University Central Hospital, Department of Paediatrics, Turku (Finland); Parkkola, Riitta [Turku University Central Hospital, Department of Radiology and Turku PET Centre, Turku (Finland); Johansson, Reijo [Turku University Central Hospital, Department of Otorhinolaryngology, Turku (Finland); Jaeaeskelaeinen, Satu K. [Turku University Central Hospital, Department of Clinical Neurophysiology, Turku (Finland); Kujari, Harry [Turku University Central Hospital, Department of Pathology, Turku (Finland); Haataja, Leena [Turku University Central Hospital, Department of Paediatric Neurology, Turku (Finland)

    2009-08-15

    Preterm and low-birth-weight infants have an increased risk of sensorineural hearing loss. Brainstem auditory-evoked potentials (BAEP) are an effective method to detect subtle deficits in impulse conduction in the auditory pathway. Abnormalities on diffusion tensor imaging (DTI) have been shown to be associated with perinatal white-matter injury and reduced fractional anisotropy (FA) has been reported in patients with sensorineural hearing loss. To evaluate the possibility of a correlation between BAEP and DTI of the inferior colliculus in preterm infants. DTI at term age and BAEP measurements were performed on all very-low-birth-weight or very preterm study infants (n=56). FA and apparent diffusion coefficient (ADC) of the inferior colliculus were measured from the DTI. Shorter BAEP wave I, III, and V latencies and I-III and I-V intervals and higher wave V amplitude correlated with higher FA of the inferior colliculus. The association between the DTI findings of the inferior colliculus and BAEP responses suggests that DTI can be used to assess the integrity of the auditory pathway in preterm infants. (orig.)

  2. The Relationship between Parameters of Long-Latency Evoked Potentials in a Multisensory Design.

    Science.gov (United States)

    Hernández, Oscar H; García-Martínez, Rolando; Monteón, Victor

    2016-10-01

    In previous papers, we have shown that parameters of the omitted stimulus potential (OSP), which occurs at the end of a train of sensory stimuli, strongly depend on the modality. A train of stimuli also produces long-latency evoked potentials (LLEP) at the beginning of the train. This study is an extension of the OSP research, and it tested the relationship between parameters (ie, rate of rise, amplitude, and peak latency) of the P2 waves when trains of auditory, visual, or somatosensory stimuli were applied. The dynamics of the first 3 potentials in the train, related to habituation, were also studied. Twenty healthy young college volunteers participated in the study. As in the OSP, the P2 was faster and higher for auditory than for visual or somatosensory stimuli. The first P2 was swifter and higher than the second and the third potentials. The strength of habituation depends on the sensory modality and the parameter used. All these findings support the view that many long-latency brain potentials could share neural mechanisms related to wave generation.

  3. Preoperative and postoperative evaluation of somatosensorial evoked potentials of upper extremities in cervical intervertebral disc herniation.

    Science.gov (United States)

    Umur, Ahmet Sukru; Selcuki, Mehmet; Selcuki, Deniz; Temiz, Cuneyt; Akbasak, Aytac

    2013-01-01

    This study aims to determine the dysfunction caused by existing pathological condition in structures involved in the transfer of sensory functions of the neural system in cervical disc herniation, and to establish whether or not the level and degree of this anatomical damage can be anticipated by SEP (Somatosensorial Evoked Potentials). We compared the obtained SEP values for statistical significance using the Friedman Variation Analysis. In parameters with statistical significance, the Wilcoxon Signed Rank test was used to identify when significant improvements occurred. The study found that the statistical data of the latency of the N14 wave originating from the dorsal column nuclei of the medulla spinalis and dorsal column gray matter improved (p < 0.05) in the postoperative period compared with the preoperative values. Using the Wilcoxon Signed Rank test, we studied postoperative months separately in regard to the difference in the latency of the N14 wave, and found the statistically significant improvement to be marked particularly in months 3 and 6 postoperatively (p < 0.05). In conclusion, we suggest that SEP is a useful tool to check the functional condition of the dorsal spinal column. The benefit of the SEP utilization is the ability to determine the severity of the pathological condition preoperatively and follow the patient's functional postoperative improvement.

  4. Alcohol Effects on the P2 component of Auditory Evoked Potentials

    Directory of Open Access Journals (Sweden)

    OSCAR H. HERNÁNDEZ

    2014-03-01

    Full Text Available This is a second part of a research aimed to study the effects of alcohol on the electrophysiological processes in student volunteers. The first part showed that alcohol slowed the Omitted Stimulus Potential (OSP. This work studied the ethanol effects on the parameters (i.e. rate of rise, amplitude and peak latency of the P2 component of the evoked potentials (EPs yielded by trains of auditory stimuli. It is hypothesized here that if P2 and OSP waves share some common neural processes then alcohol should also affect these specific parameters. A dose of 0.8 g/kg of alcohol or a placebo (0 g/kg was administered to two groups of 15 young men who were tested before and again after treatment. The pre-post treatment change in each of the measurements was used to assess the treatment effects. The results showed that compared to placebo, alcohol slowed the P2 rise rate and reduced its amplitude, with no effects on peak latency. The rise rate is more sensitive to alcohol but more resistant to the adaptation process. Alcohol resembles the response inhibition model acting against the adaptation. The rise rate of the P2 and the OSP waves are affected by alcohol in a similar fashion, suggesting similar neural generative mechanisms.

  5. Learned control over spinal nociception reduces supraspinal nociception as quantified by late somatosensory evoked potentials.

    Science.gov (United States)

    Ruscheweyh, Ruth; Bäumler, Maximilian; Feller, Moritz; Krafft, Stefanie; Sommer, Jens; Straube, Andreas

    2015-12-01

    We have recently shown that subjects can learn to use cognitive-emotional strategies to suppress their spinal nociceptive flexor reflex (RIII reflex) under visual RIII feedback and proposed that this reflects learned activation of descending pain inhibition. Here, we investigated whether learned RIII suppression also affects supraspinal nociception and whether previous relaxation training increases success. Subjects were trained over 3 sessions to reduce their RIII size by self-selected cognitive-emotional strategies. Two groups received true RIII feedback (with or without previous relaxation training) and a sham group received false feedback (15 subjects per group). RIII reflexes, late somatosensory evoked potentials (SEPs), and F-waves were recorded and pain intensity ratings collected. Both true feedback groups achieved significant (P Pain intensity was significantly reduced in all 3 groups and also correlated with RIII reduction (r = 0.44, P nociception as quantified by SEPs, although effects on pain ratings were less clear. Lower motor neuron excitability as quantified by F-waves was not affected. Previous relaxation training did not significantly improve RIII feedback training success.

  6. An inventory and update of jealousy-evoking partner behaviours in modern society.

    NARCIS (Netherlands)

    Dijkstra, Pieternel; Barelds, Dick P. H.; Groothof, Hinke A. K.

    2010-01-01

    The goal of the present study was to identify the most important jealousy-evoking partner behaviours and to examine the extent to which these behaviours evoke jealousy. Based on the literature, a questionnaire was constructed containing 42 jealousy-evoking partner behaviours, including a partner's e

  7. Microhollow Cathode Discharge Excimer Lamps

    Science.gov (United States)

    Schoenbach, K. H.

    1999-11-01

    character. Reducing the diameter of the cathode hole in a hollow cathode discharge geometry to values on the order of 100 μm has allowed us to extend the pressure range of stable, direct current hollow cathode gas discharges up to atmospheric pressure. The large concentration of high-energy electrons generated in the cathode fall, in combination with the high neutral gas density favors three-body processes such as excimer formation. Excimer emission in xenon discharges peaking at 172 nm, was observed with efficiencies between 6% and 9% at pressures of several hundred Torr. Typical forward voltages are 200 V at dc currents up to 8 mA. Pulsed operation allowed us to extend the current range to 80 mA with corresponding linear increase in optical power. Spatially resolved measurements showed that the source of the excimer radiation at atmospheric pressure and currents of less than 8 mA is confined to the cathode opening. The radiative emittance at 8 mA and atmospheric pressure is approximately 20 W/cm^2. With reduced pressure and increased current, respectively, the excimer source extends into the area outside the cathode hole. Besides in xenon, excimer emission in argon at a peak wavelength of 128 nm has been recorded. In addition to operating the discharge in rare gases, we have also explored its use as rare gas-halide excimer source. In a gas mixture containing 1% ArF we were able to generate stable dc discharges in flowing gas at pressures ranging from 100 Torr to atmospheric pressure. The spectra of the high-pressure ArF discharges are dominated by excimer radiation peaking at 193 nm. The excimer emission of a single ArF discharge at 700 Torr was measured as 150 mW at an efficiency of 3%. Parallel operation of these discharges by means of a resistive anode, which has recently been demonstrated for argon discharges, offers the possibility to use microhollow cathode discharge arrays as dc-excimer lamps, with estimated power densities exceeding 10 W/cm^2. abstract

  8. Water purification by electrical discharges

    Science.gov (United States)

    Arif Malik, Muhammad; Ghaffar, Abdul; Akbar Malik, Salman

    2001-02-01

    There is a continuing need for the development of effective, cheap and environmentally friendly processes for the disinfection and degradation of organic pollutants from water. Ozonation processes are now replacing conventional chlorination processes because ozone is a stronger oxidizing agent and a more effective disinfectant without any side effects. However, the fact that the cost of ozonation processes is higher than chlorination processes is their main disadvantage. In this paper recent developments targeted to make ozonation processes cheaper by improving the efficiency of ozone generation, for example, by incorporation of catalytic packing in the ozone generator, better dispersion of ozone in water and faster conversion of dissolved ozone to free radicals are described. The synthesis of ozone in electrical discharges is discussed. Furthermore, the generation and plasma chemical reactions of several chemically active species, such as H2O2, Obullet, OHbullet, HO2bullet, O3*, N2*, e-, O2-, O-, O2+, etc, which are produced in the electrical discharges are described. Most of these species are stronger oxidizers than ozone. Therefore, water treatment by direct electrical discharges may provide a means to utilize these species in addition to ozone. Much research and development activity has been devoted to achieve these targets in the recent past. An overview of these techniques and important developments that have taken place in this area are discussed. In particular, pulsed corona discharge, dielectric barrier discharge and contact glow discharge electrolysis techniques are being studied for the purpose of cleaning water. The units based on electrical discharges in water or close to the water level are being tested at industrial-scale water treatment plants.}

  9. TYPE-2 DIABETES MELLITUS AND BRAIN STEM EVOKED RESPONSE AUDIOMETRY: A CASE CONTROL STUDY

    Directory of Open Access Journals (Sweden)

    Praveen S

    2016-01-01

    Full Text Available BACKGROUND AND OBJECTIVE Type-2 Diabetes Mellitus (T2DM causes pathophysiological changes in multiple organ system. The peripheral, autonomic and central neuropathy is known to occur in T2DM, which can be studied electrophysiologically. AIM Present study is aimed to evaluate functional integrity of auditory pathway in T2DM by Brainstem Evoked Response Audiometry (BERA. MATERIAL AND METHOD In the present case control study, BERA was recorded from the scalp of 20 T2DM patients aged 30-65 years and were compared with age matched 20 healthy controls. The BERA was performed using EMG Octopus, Clarity Medical Pvt. Ltd. The latencies of wave I, III, V and Wave I-III, I-V and III-V interpeak latencies of both right and left ear were recorded at 70dBHL. STATISTICAL RESULT AND USE Mean±SD of latencies of wave I, III, V and interpeak latency of I-III, I-V and III-V were estimated of T2DM and healthy controls. The significant differences between the two groups were assessed using unpaired student ‘t’ test for T2DM and control groups using GraphPad QuickCalcs calculator. P value <0.05 was considered to be significant. RESULT In T2DM BERA study revealed statistically significant (p<0.05 prolonged latencies of wave I, III and V in both right (1.81±0.33ms, 3.96±0.32ms, 5.60±0.25ms and left (1.96±0.24ms, 3.79±0.22ms, 5.67±0.25ms ear as compared to controls at 70dB. Wave III-V interpeak latency of left ear (1.87±0.31, 1.85±0.41ms and wave I-III (2.51±0.42ms, 1.96±0.48ms and III-V (2.01±0.43ms, 1.76±0.45ms of right ear was prolonged in diabetic patient as compared to controls, although no significant difference was obtained (p<0.05. INTERPRETATION AND CONCLUSION Increase in absolute latencies and interpeak latencies inT2DM patients suggest involvement of central neuronal axis at the level of brain stem and midbrain.

  10. Making waves

    Science.gov (United States)

    Kruse, Karsten

    2017-01-01

    Traveling waves propagating along surfaces play an important role for intracellular organization. Such waves can appear spontaneously in reaction-diffusion systems, but only few general criteria for their existence are known. Analyzing the dynamics of the Min proteins in Escherichia coli, Levine and Kessler (2016 New J. Phys. 18 122001) now identified a new mechanism for the emergence of traveling waves that relies on conservation laws. From their analysis one can expect traveling waves to be a generic feature of systems made of proteins that have a cytoplasmic and a membrane-bound state.

  11. Janus Waves

    OpenAIRE

    2016-01-01

    We show the existence of a family of waves that share a common interesting property affecting the way they propagate and focus. These waves are a superposition of twin waves, which are conjugate to each other under inversion of the propagation direction. In analogy to holography, these twin "real" and "virtual" waves are related respectively to the converging and the diverging part of the beam and can be clearly visualized in real space at two distinct foci under the action of a focusing lens...

  12. Multimodal evoked potentials in spinocerebellar ataxia types 1, 2, and 3

    Directory of Open Access Journals (Sweden)

    Vijay Chandran

    2014-01-01

    Full Text Available Aims: Spinocerebellar ataxias (SCA are a clinically heterogeneous group of disorders that are characterized by ataxia and an autosomal dominant pattern of inheritance. The aim of our study was to describe the findings of evoked potentials (EPs among genetically proven SCA types 1, 2, and 3 and to additionally evaluate if EPs can be used to differentiate between them. Materials and Methods: Forty-three cases of genetically proven SCA (SCA1 = 19, SCA2 = 13, and SCA3 = 11 were evaluated with median somatosensory-EP (mSSEP, visual-EP (VEP, and brainstem auditory-evoked response (BAER by standard procedures and compared with normative laboratory data. An EP was considered abnormal if latency was prolonged (>mean + 3 standard deviation (SD of laboratory control data or the waveform was absent or poorly defined. The waves studied were as follows: mSSEP - N20, VEP - P100 and BAER - interpeak latency 1-3 and 3-5. Results: EPs were abnormal in at least one modality in 90.9% of patients. The most common abnormality was of BAER (86.1% followed by VEP (34.9% and mSSEP (30.2%. The degree of abnormality in VEP, mSSEP, and BAER among patients with SCA1 was 42.1, 41.2, and 73.3%, respectively; among patients with SCA2 was 38.5, 27.3, and 100%, respectively; and among patients with SCA3 was 18.2, 37.5, and 88.9%, respectively. The differences between the subgroups of SCAs were not statistically significant. Conclusions: BAER was the most frequent abnormality in SCA types 1, 2, and 3; abnormalities of mSSEP were comparable in the three SCAs; whereas, abnormality of VEP was less often noted in SCA3.

  13. Giant early components of somatosensory evoked potentials to tibial nerve stimulation in cortical myoclonus.

    Science.gov (United States)

    Anzellotti, Francesca; Onofrj, Marco; Bonanni, Laura; Saracino, Antonio; Franciotti, Raffaella

    2016-01-01

    Enlarged cortical components of somatosensory evoked potentials (giant SEPs) recorded by electroencephalography (EEG) and abnormal somatosensory evoked magnetic fields (SEFs) recorded by magnetoencephalography (MEG) are observed in the majority of patients with cortical myoclonus (CM). Studies on simultaneous recordings of SEPs and SEFs showed that generator mechanism of giant SEPs involves both primary sensory and motor cortices. However the generator sources of giant SEPs have not been fully understood as only one report describes clearly giant SEPs following lower limb stimulation. In our study we performed a combined EEG-MEG recording on responses elicited by electric median and tibial nerve stimulation in a patient who developed consequently to methyl bromide intoxication CM with giant SEPs to median and tibial nerve stimuli. SEPs wave shapes were identified on the basis of polarity-latency components (e.g. P15-N20-P25) as defined by earlier studies and guidelines. At EEG recording, the SEP giant component did not appear in the latency range of the first cortical component for median nerve SEP (N20), but appeared instead in the range of the P37 tibial nerve SEP, which is currently identified as the first cortical component elicited by tibial nerve stimuli. Our MEG and EEG SEPs recordings also showed that components in the latency range of P37 were preceded by other cortical components. These findings suggest that lower limb P37 does not correspond to upper limb N20. MEG results confirmed that giant SEFs are the second component from both tibial (N43m-P43m) and median (N27m-P27m) nerve stimulation. MEG dipolar sources of these giant components were located in the primary sensory and motor area.

  14. Contralateral acoustic suppression of transient evoked otoacoustic emissions: Activation of the medial olivocochlear system

    Directory of Open Access Journals (Sweden)

    Komazec Zoran

    2003-01-01

    Full Text Available Medial olivocochlear pathway represents the final part of efferent acoustic pathway which comes from the superior olivary complex ending at outer hair cells. Activation of medial olivocochlear system (MOCS alters the cochlear output decreasing the travelling wave within cochlea. Stimulation of MOCS provides protection against moderate levels of noise, encoding noise signals as well as selecting hearing attention. Activation of MOCS can be performed using contralateral acoustic stimulation. The principal result of presentation of contralateral acoustic stimulation during screening of transient evoked otoacoustic emission (TEOAE is an attenuation of the TEOAE amplitude. Thirty-eight ears were examined in this study: twenty-eight ears from 14 normal-hearing adults and 10 patients with unilateral deafness. Healthy subjects were exposed to contralateral broad-band noise of various intensities (40, 30, 20 and 10 dB SL, as well as 30 dB SL pure tone stimulation (1 kHz and 4 kHz. A decrease of TEOAE amplitudes during contralateral stimulation with 40 and 30 dB SL broad-band noise and pure tones was established. This effect was a result of MOCS activation. A greater intensity of contralateral stimulation evoked greater decrease of TEOAE amplitude; stimulation with broad-band noise caused greater attenuation than with pure tone stimulation. Contralateral stimulation of deaf ears in the group with unilateral deafness was also performed. Statistically significant difference between TEOAE amplitude before and during contralateral stimulation was not established. This circumstance explains that activation of MOCS and consequent reduction of outer hair cells motility is very possibly caused by contralateral acoustic stimulation. Apart from studying physiological significance of efferent auditory system, results of this and similar studies can be used for production of hearing aids improving speech discrimination in noisy environment.

  15. Are flash-evoked visual potentials useful for intraoperative monitoring of visual pathway function?

    Science.gov (United States)

    Cedzich, C; Schramm, J; Fahlbusch, R

    1987-11-01

    Flash-evoked visual potentials (VEPs) recorded from the scalp were used in a series of 35 patients with tumors along the visual pathway: 3 orbital tumors, 25 perisellar tumors, 4 intraventricular tumors, and 3 occipital lesions. Preoperatively, various combinations of impaired visual fields and visual acuity were observed in over 90% of the patients. A postoperative decrease in visual function was observed in 3 cases. Of the 25 perisellar lesions, 13 were operated through a standard frontotemporal craniotomy and 12 were operated through a transnasal-transsphenoidal approach. VEPs were highly susceptible to volatile anesthetics, and there was a significant incidence of spontaneous latency increases and amplitude decreases in a large number of patients. There was an unacceptably high number of cases with significant VEP alteration occurring without concomitant visual function change. During trepanation or the transnasal approach, a reversible potential loss was observed in 11 patients, a profoundly altered wave form was seen in 8 cases, and a loss of single peaks was observed in 15 patients. During dissection of the tumor, a reversible potential loss or a potential with unidentifiable peaks was found in 25 cases; however, the VEPs recovered during closure or in the recovery room. There was no correlation between intraoperative VEP changes and the postoperative changes in visual function. In only 1 patient with an insignificant postoperative decrease in visual acuity from 0.4 to 0.3 was there a concomitant intraoperative potential loss. The major conclusion of our findings is that light-emitting diode flash-evoked VEPs demonstrate intraoperative changes that appear too early and too prominently to be caused solely by manipulation of the optic pathways.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Timing of evoked potentials forecasting the prognosis of severe stroke patients

    Directory of Open Access Journals (Sweden)

    Shu-ying XIAO

    2015-12-01

    Full Text Available Objective To investigate the best assessment time of short-latency somatosensory-evoked potential (SLSEP and brain stem auditory-evoked potential (BAEP in predicting the prognosis of patients with acute severe stroke. Methods Fifty-two patients who were diagnosed as supratentorial massive cerebral infarction or large-volume cerebral hemorrhage by brain CT and/or MRI examination with Glasgow Coma Scale (GCS ≤ 12 were selected as observation subjects. GCS, SLSEP and BAEP were recorded at 1-3 and 4-7 d after onset. Outcomes were examined 6 months later using the modified Rankin Scale (mRS. A mRS score of 0-4 was considered as favorable outcome while a score of 5-6 was considered as unfavorable. The correlation between different predictive indexes (GCS, SLSEP and BAEP and outcome (mRS was analyzed. The predictive accuracy was also analyzed. Results At 1-3 d after onset, there was no correlation between all the predictors and outcome (P > 0.05, for all. At 4-7 d after onset, SLSEP and BAEP were significantly correlated with mRS (P < 0.01, for all; C > 0.400. At 4-7 d after onset, the prognostic sensitivity of SLSEP and BAEP Ⅴ wave was 85.71%-97.62% ; prognostic specificity of BAEP was 80.00%-90.00%; positive predictive value of all predictors was 89.13%-96.88%; negative predictive value of SLSEP was 83.33%-85.71% ; total predictive accuracy of SLSEP was 88.46%-90.38%. The predictive accuracy of both SLSEP and BAEP achieved the clinical expectation, and the former is better than the latter. Conclusions SLSEP and BAEP have a high accuracy rate in predicting the unfavorable prognosis of patients with acute severe stroke 4-7 d after onset. DOI: 10.3969/j.issn.1672-6731.2015.12.004

  17. Electric field measurements in a nanosecond pulse discharge in atmospheric air

    Science.gov (United States)

    Simeni Simeni, Marien; Goldberg, Benjamin M.; Zhang, Cheng; Frederickson, Kraig; Lempert, Walter R.; Adamovich, Igor V.

    2017-05-01

    The paper presents the results of temporally and spatially resolved electric field measurements in a nanosecond pulse discharge in atmospheric air, sustained between a razor edge high-voltage electrode and a plane grounded electrode covered by a thin dielectric plate. The electric field is measured by picosecond four-wave mixing in a collinear phase-matching geometry, with time resolution of approximately 2 ns, using an absolute calibration provided by measurements of a known electrostatic electric field. The results demonstrate electric field offset on the discharge center plane before the discharge pulse due to surface charge accumulation on the dielectric from the weaker, opposite polarity pre-pulse. During the discharge pulse, the electric field follows the applied voltage until ‘forward’ breakdown occurs, after which the field in the plasma is significantly reduced due to charge separation. When the applied voltage is reduced, the field in the plasma reverses direction and increases again, until the weak ‘reverse’ breakdown occurs, producing a secondary transient reduction in the electric field. After the pulse, the field is gradually reduced on a microsecond time scale, likely due to residual surface charge neutralization by transport of opposite polarity charges from the plasma. Spatially resolved electric field measurements show that the discharge develops as a surface ionization wave. Significant surface charge accumulation on the dielectric surface is detected near the end of the discharge pulse. Spatially resolved measurements of electric field vector components demonstrate that the vertical electric field in the surface ionization wave peaks ahead of the horizontal electric field. Behind the wave, the vertical field remains low, near the detection limit, while the horizontal field is gradually reduced to near the detection limit at the discharge center plane. These results are consistent with time-resolved measurements of electric field

  18. Ritual relieved axial dystonia triggered by gaze-evoked amaurosis.

    Science.gov (United States)

    Jacome, D E

    1997-11-01

    A woman with chronic posttraumatic axial lateropulsion cervical dystonia ("belly dancer's head") found relief of her spontaneous dystonic spasms by the sequential performance of an elaborate motor ritual. During an episode of left optic papillitis caused by central retinal vein occlusion, gaze-evoked amaurosis of the left eye developed, preceded by achromatopsia, during left lateral gaze. Gaze-evoked amaurosis triggered axial dystonia, which was followed by her unique, stereotyped, dystonia-relieving ritual that simulated a slow dance. Visual symptoms improved progressively in 1 year. Eventually, she was unable to trigger her dystonia by eye movements. Spontaneous dystonia remained otherwise unchanged from before the episode of papillitis and was still relieved by her unique ritual.

  19. Evoked potentials and head injury. 2. Clinical applications.

    Science.gov (United States)

    Rappaport, M; Hopkins, H K; Hall, K; Belleza, T

    1981-10-01

    The method of rating abnormality of evoked brain potential patterns and assessing the extent and severity of cortical and subcortical brain dysfunction in head injury patients described in Part I is applied in a clinical context. Evoked potential abnormality (EPA) scores are found to be significantly correlated both with admission and outcome disability approximately one year after head injury. Correlations increase with the increase in the number of sensory modalities tested. Correlations between EPA scores and clinical disability (measured by the Disability Rating Scale) decrease with time after injury. Significant correlations, however, persist for about 60 days after onset of injury. It was found that EP pattern abnormalities can reflect specific sensory (and at times motor) deficits in noncommunicative patients and thereby contribute significantly to early treatment and rehabilitation planning.

  20. Evoked response audiometry used in testing auditory organs of miners

    Energy Technology Data Exchange (ETDEWEB)

    Malinowski, T.; Klepacki, J.; Wagstyl, R.

    1980-01-01

    The evoked response audiometry method of testing hearing loss is presented and the results of comparative studies using subjective tonal audiometry and evoked response audiometry in tests of 56 healthy men with good hearing are discussed. The men were divided into three groups according to age and place of work: work place without increased noise; work place with noise and vibrations (at drilling machines); work place with noise and shocks (work at excavators in surface coal mines). The ERA-MKII audiometer produced by the Medelec-Amplaid firm was used. Audiometric threshhold curves for the three groups of tested men are given. At frequencies of 500, 1000 and 4000 Hz mean objective auditory threshhold was shifted by 4-9.5 dB in comparison to the subjective auditory threshold. (21 refs.) (In Polish)

  1. Temporal resolution in the hearing system and auditory evoked potentials

    DEFF Research Database (Denmark)

    Miller, Lee; Beedholm, Kristian

    2008-01-01

    3pAB5. Temporal resolution in the hearing system and auditory evoked potentials. Kristian Beedholm Institute of Biology,University of Southern Denmark, Campusvej 55, 5230 Odense M, Denmark, beedholm@mail.dk, Lee A. Miller Institute of Biology,University of Southern Denmark, Campusvej 55, 5230...... of the MRTF is not straight forward, but is often used as a measure of the ability of the auditory system to encodetemporal changes. It is, however, shown here that the MRTF must depend on the waveform of the click-evoked AEP ceAEP, whichdoes not relate directly to temporal resolution. The theoretical...... of 0.5 ms Hann weighted130 kHz tone pips presented at an increasing rate chirped over a time span of 32 ms. The results reveal that the system's responsivenessdeclines roughly exponentially as a function of click rate with a rate constant of about -0.7 kHz and appears more rate limited thanimplied...

  2. Abdominal acupuncture reduces laser-evoked potentials in healthy subjects

    DEFF Research Database (Denmark)

    Pazzaglia, C.; Liguori, S.; Minciotti, I.

    2015-01-01

    Objective: Acupuncture is known to reduce clinical pain, although the exact mechanism is unknown. The aim of the current study was to investigate the effect of acupuncture on laser-evoked potential amplitudes and laser pain perception. Methods: In order to evaluate whether abdominal acupuncture...... is able to modify pain perception, 10 healthy subjects underwent a protocol in which laser-evoked potentials (LEPs) and laser pain perception were collected before the test (baseline), during abdominal acupuncture, and 15. min after needle removal. The same subjects also underwent a similar protocol...... in which, however, sham acupuncture without any needle penetration was used. Results: During real acupuncture, both N1 and N2/P2 amplitudes were reduced, as compared to baseline (p . < 0.01). The reduction lasted up to 15. min after needle removal. Furthermore, laser pain perception was reduced during...

  3. The transfer of avoidance evoking functions through stimulus equivalence classes.

    Science.gov (United States)

    Augustson, E M; Dougher, M J

    1997-09-01

    Recent research in the area of stimulus equivalence suggests that transfer of function via members of stimulus equivalence classes may have relevance to human emotional responding and the development and generalization of certain psychological disorders. This study investigated the transfer of avoidance evoking functions through equivalence classes. Eight subjects were trained in the necessary relations for two-four member stimulus equivalence classes to emerge. Next, using an on-baseline classical conditioning procedure, one member of one class was paired with shock while one member of the other class was presented without shock. Then, while subjects engaged a key-press task, a differential, signalled avoidance task was introduced wherein shock was avoided if a response occurred to the stimulus previously associated with shock. The remaining stimuli from both classes were then presented. The behavior of all eight subjects showed the differential transfer of the avoidance evoking function. The clinical and theoretical implications of the results are discussed.

  4. Short latency vestibular evoked potentials in the chicken embryo

    Science.gov (United States)

    Jones, S. M.; Jones, T. A.

    1996-01-01

    Electrophysiological responses to pulsed linear acceleration stimuli were recorded in chicken embryos incubated for 19 or 20 days (E19/E20). Responses occurred within the first 16 ms following the stimulus onset. The evoked potentials disappeared following bilateral labyrinthectomy, but persisted following cochlear destruction alone, thus demonstrating that the responses were vestibular. Approximately 8 to 10 response peaks could be identified. The first 4 positive and corresponding negative components (early peaks with latencies embryos was -15.9dBre 1.0 g/ms, which was significantly higher (P embryos and 2-week-old animals, but amplitude/intensity functions for embryos were significantly shallower than those for 2-week-old birds (P embryo and, as such, the method shows promise as an investigative tool. The results of the present study form the definitive basis for using vestibular evoked potentials in the detailed study of avian vestibular ontogeny and factors that may influence it.

  5. Visual evoked potentials in a patient with prosopagnosia.

    Science.gov (United States)

    Small, M

    1988-01-01

    Visual evoked potentials (VEPs) were recorded from a 53-year-old man with prosopagnosia during presentation of slides of known and unknown faces and under two control conditions. ANOVA comparisons with a normal male group showed no differences in P100 amplitude, P300 amplitude or P300 latency. There were no significant evoked potential differences between the patient and controls specifically related to the face conditions. There was, however, a significant delay in the latency of P100 from both hemispheres during all types of stimuli. This prolonged latency was asymmetrical, showing a right sided emphasis with the control conditions: pattern reversal and slides of geometric designs. This finding, of a dissociation in the interhemispheric delay, provides physiological evidence of stimulus-specific organisation at an early, sensory level. The fact that the P100 component showed a marked delay, yet P300 fell within normal limits for amplitude and latency, suggests that this patient's problem lies at a perceptual level.

  6. Application of transient evoked otoacoustic emissions to pediatric populations.

    Science.gov (United States)

    Norton, S J

    1993-02-01

    Transient evoked otoacoustic emissions (TEOAEs) occur after presentation of brief acoustic stimuli such as clicks and tone pips. They represent physiological activity from within the cochlea, specifically from normal functioning outer hair cells. TEOAEs are frequency specific in that their spectra are determined by the spectra of the evoking stimulus and the audiometric configuration. TEOAEs are sensitive to mild to moderate degrees of cochlear hearing loss up to about 40 to 50 dB HL. They can be measured rapidly and noninvasively in infants and children. Among the potential applications in pediatric audiology are screening for hearing impairment in neonates, separating peripheral hearing loss and central auditory dysfunction, and monitoring cochlear status in children receiving ototoxic drugs.

  7. A Microwave Plasma Discharge in Rare Gases as a VUV Source for Planetary Atmospheric Photochemistry

    OpenAIRE

    Tigrine, Sarah; Carrasco, Nathalie; Vettier, Ludovic; Cernogora, Guy

    2016-01-01

    International audience; The aim of this work is to show that micro-wave discharges in rare gases, can be an efficient windowless VUV photon source for planetaryatmospheric photochemistry experiments. In this context, we perform a microwave discharge (surfatron) in a neon gas flow. We characterizethe VUV photon flux emitted in different conditions, when working in the mbar pressure range, and compare it to synchrotron VUV fluxes alsoused for similar applications.

  8. Computer Processing of Visual Evoked Potentials Utilizing Digital Filtering Techniques

    OpenAIRE

    Vigorito, A.; Stephens, G.; Louis, H; Cinotti, A.; Michelson, L.; E. Stephens

    1981-01-01

    Recording of the VER (Visual Evoked Response) and the ERG (ElectroRetinoGram) in our laboratory is done with stimulation, using a fixed checkerboard pattern or a reversible checkerboard pattern. Questionable data frames are eliminated from the signal averaging process by means of a semiautomatic electronic analyzer or by means of a computer program. This special computer software, with flexible format constraints, is utilized on an off-line basis to remove residual artifacts and noise from av...

  9. Brain stem auditory evoked responses in chronic alcoholics.

    OpenAIRE

    Chan, Y W; McLeod, J G; Tuck, R R; Feary, P A

    1985-01-01

    Brain stem auditory evoked responses (BAERs) were performed on 25 alcoholic patients with Wernicke-Korsakoff syndrome, 56 alcoholic patients without Wernicke-Korsakoff syndrome, 24 of whom had cerebellar ataxia, and 37 control subjects. Abnormal BAERs were found in 48% of patients with Wernicke-Korsakoff syndrome, in 25% of alcoholic patients without Wernicke-Korsakoff syndrome but with cerebellar ataxia, and in 13% of alcoholic patients without Wernicke-Korsakoff syndrome or ataxia. The mean...

  10. Cerebral oxygen delivery and consumption during evoked neural activity

    Directory of Open Access Journals (Sweden)

    Alberto L Vazquez

    2010-06-01

    Full Text Available Increases in neural activity evoke increases in the delivery and consumption of oxygen. Beyond observations of cerebral tissue and blood oxygen, the role and properties of cerebral oxygen delivery and consumption during changes in brain function are not well understood. This work overviews the current knowledge of functional oxygen delivery and consumption and introduces recent and preliminary findings to explore the mechanisms by which oxygen is delivered to tissue as well as the temporal dynamics of oxygen metabolism. Vascular oxygen tension measurements have shown that a relatively large amount of oxygen exits pial arterioles prior to capillaries. Additionally, increases in cerebral blood flow (CBF induced by evoked neural activation are accompanied by arterial vasodilation and also by increases in arteriolar oxygenation. This increase contributes not only to the down-stream delivery of oxygen to tissue, but also to delivery of additional oxygen to extra-vascular spaces surrounding the arterioles. On the other hand, the changes in tissue oxygen tension due to functional increases in oxygen consumption have been investigated using a method to suppress the evoked CBF response. The functional decreases in tissue oxygen tension induced by increases in oxygen consumption are slow to evoked changes in CBF under control conditions. Preliminary findings obtained using flavoprotein autofluorescence imaging suggest cellular oxidative metabolism changes at a faster rate than the average changes in tissue oxygen. These issues are important in the determination of the dynamic changes in tissue oxygen metabolism from hemoglobin-based imaging techniques such as blood oxygenation-level dependent functional magnetic resonance imaging (fMRI.

  11. Temporal suppression and augmentation of click-evoked otoacoustic emissions

    DEFF Research Database (Denmark)

    Verhulst, Sarah; Harte, James; Dau, Torsten

    2008-01-01

    This study investigates and models temporal suppression of click-evoked otoacoustic emissions (CEOAEs). This suppression-effect is created when a suppressor-click is presented close in time to a test-click. The analysis was carried out for short time-frames of short- and long-latency CEOAEs. The ...... phenomenologically using compression or expansion of the system output. This was obtained by shifting the operating-point on the input-output-characteristic in relation to the ICI....

  12. [Visual evoked potentials (VEP) in anesthesia and intensive care].

    Science.gov (United States)

    Russ, W; Krumholz, W; Hempelmann, G

    1984-03-01

    Methodological considerations and different stimulation techniques of visual evoked potentials (VEP) are described. VEP can provide information about neurological function during anaesthesia, surgery and in the unconscious patient after head injury. The feasibility of the method for intraoperative monitoring in neuro- and cardiac surgery and the influence of general anaesthetics and other contributing factors such as temperature, paCO2, pO2, part are discussed.

  13. Pattern shift visual evoked response: application in neurology

    Directory of Open Access Journals (Sweden)

    Carlos A. M. Guerreiro

    1982-03-01

    Full Text Available The technique that we use for pattern shift visual evoked response (PSVER is described. PSVER is a non-invasive, practical and reliable clinical test in detecting anterior visual pathways lesions even when asymptomatic. The ability to find unsuspected lesions in multiple sclerosis, making possible an early diagnosis, is underscored. We also discuss some pathophysiologic aspects and the findings of the PSVER in some neurologic disorders with visual system involvement.

  14. Submillisecond unmasked subliminal visual stimuli evoke electrical brain responses.

    Science.gov (United States)

    Sperdin, Holger F; Spierer, Lucas; Becker, Robert; Michel, Christoph M; Landis, Theodor

    2015-04-01

    Subliminal perception is strongly associated to the processing of meaningful or emotional information and has mostly been studied using visual masking. In this study, we used high density 256-channel EEG coupled with an liquid crystal display (LCD) tachistoscope to characterize the spatio-temporal dynamics of the brain response to visual checkerboard stimuli (Experiment 1) or blank stimuli (Experiment 2) presented without a mask for 1 ms (visible), 500 µs (partially visible), and 250 µs (subliminal) by applying time-wise, assumption-free nonparametric randomization statistics on the strength and on the topography of high-density scalp-recorded electric field. Stimulus visibility was assessed in a third separate behavioral experiment. Results revealed that unmasked checkerboards presented subliminally for 250 µs evoked weak but detectable visual evoked potential (VEP) responses. When the checkerboards were replaced by blank stimuli, there was no evidence for the presence of an evoked response anymore. Furthermore, the checkerboard VEPs were modulated topographically between 243 and 296 ms post-stimulus onset as a function of stimulus duration, indicative of the engagement of distinct configuration of active brain networks. A distributed electrical source analysis localized this modulation within the right superior parietal lobule near the precuneus. These results show the presence of a brain response to submillisecond unmasked subliminal visual stimuli independently of their emotional saliency or meaningfulness and opens an avenue for new investigations of subliminal stimulation without using visual masking. © 2014 Wiley Periodicals, Inc.

  15. Evoked otoacoustic emissions in workers exposed to noise: A review

    Directory of Open Access Journals (Sweden)

    Alcarás, Patrícia Arruda de Souza

    2012-01-01

    Full Text Available Introduction: The otoacoustic emissions test is an essential tool in the evaluation of auditory function, since it allows the early detection of cochlear damage of occupational origin. Objective: To present a review of the literature and analyze the effectiveness of the clinical application of the otoacoustic emissions test in workers exposed to noise. Methods: A bibliographical search covering a period of 10 years was performed in the Virtual Health Library including published articles in national and international journals indexed in the internationally recognized databases for the health sciences, LILACS, SCIELO, and MEDLINE, using the terms "otoacoustic emissions" and "occupational exposure." The type of published article (national/international, the type and intensity of the stimulus most commonly used for the evoked otoacoustic emissions, the gender and age of the subjects, and the conclusions from the retrospective studies were all taken into consideration. Results and Conclusions: A total of 19 articles were analyzed, 7 national and 12 international, covering subjects from 17 to 77 years of age, mostly men. The type of stimulus most commonly used for the evoked otoacoustic emissions was the distortion method (12. Through this review, we have concluded that testing of evoked otoacoustic emissions in workers exposed to noise is an important tool in the early diagnosis of noise-induced cochlear hearing disorders.

  16. Perceptual learning of acoustic noise generates memory-evoked potentials.

    Science.gov (United States)

    Andrillon, Thomas; Kouider, Sid; Agus, Trevor; Pressnitzer, Daniel

    2015-11-01

    Experience continuously imprints on the brain at all stages of life. The traces it leaves behind can produce perceptual learning [1], which drives adaptive behavior to previously encountered stimuli. Recently, it has been shown that even random noise, a type of sound devoid of acoustic structure, can trigger fast and robust perceptual learning after repeated exposure [2]. Here, by combining psychophysics, electroencephalography (EEG), and modeling, we show that the perceptual learning of noise is associated with evoked potentials, without any salient physical discontinuity or obvious acoustic landmark in the sound. Rather, the potentials appeared whenever a memory trace was observed behaviorally. Such memory-evoked potentials were characterized by early latencies and auditory topographies, consistent with a sensory origin. Furthermore, they were generated even on conditions of diverted attention. The EEG waveforms could be modeled as standard evoked responses to auditory events (N1-P2) [3], triggered by idiosyncratic perceptual features acquired through learning. Thus, we argue that the learning of noise is accompanied by the rapid formation of sharp neural selectivity to arbitrary and complex acoustic patterns, within sensory regions. Such a mechanism bridges the gap between the short-term and longer-term plasticity observed in the learning of noise [2, 4-6]. It could also be key to the processing of natural sounds within auditory cortices [7], suggesting that the neural code for sound source identification will be shaped by experience as well as by acoustics.

  17. Cervical and ocular vestibular evoked myogenic potentials in Behcet's disease.

    Science.gov (United States)

    Bayram, Ali; Doğan, Murat; Koç, Ali; Kalkan, Mehmet; Akçadağ, Alper; Özcan, İbrahim

    2015-01-01

    To investigate vestibular evoked myogenic potentials combined with audiologic status in Behcet's disease (BD) and to compare the results with normal healthy subjects. Cervical vestibular evoked myogenic potential (cVEMP) test, ocular vestibular evoked myogenic potential (oVEMP) test, Dix-Hallpike test, conventional pure tone audiometry (cPTA) and high frequency audiometry (HFA), and 226 and 1000Hz tympanometry were performed to each subject of the study. Cranial magnetic resonance imaging (MRI) with contrast enhancement was also performed to evaluate the central nervous system (CNS) in patients with BD. VEMP parameters including the mean peak latencies of p13-n23 and n10-p15, AR values and thresholds were not statistically different both in cVEMP and oVEMP between the BD and control groups. Except for 250Hz, mean audiological thresholds were significantly higher in the BD group. Five of the 20 patients had pathological cranial MRI findings that may be compatible with central nervous system involvement. To our knowledge, the present study is the first report investigating oVEMP and cVEMP responses combined with MRI findings in patients with BD. The presence of high frequency hearing loss is a common finding in BD and HFA may help early detection of hearing loss in patients with BD when combined with cPTA. Copyright © 2015 Elsevier Inc. All rights reserved.

  18. Somatosensory evoked magnetic fields in patients with stroke.

    Science.gov (United States)

    Maclin, E L; Rose, D F; Knight, J E; Orrison, W W; Davis, L E

    1994-12-01

    We used magnetoencephalography to evaluate areas of sensory cortex in patients with ischemic strokes involving the somatomotor system. We measured somatosensory evoked magnetic fields using a 7-channel neuromagnetometer and estimated the location of cortical responses to median nerve stimulation in 5 patients with cortical or subcortical strokes involving the somatomotor system. All patients underwent quantitative neurological examinations and a high resolution volumetric magnetic resonance imaging. The estimated current dipoles were localized onto the patient's own MRI scan in all patients with measurable responses. The location of the estimated dipole was always in non-infarcted tissue in the anatomical region of the somatosensory cortex. In 1 patient the somatosensory dipole localized to a peninsula of cortex flanked by infarcted tissue. Single photon emission computed tomography found the localized area of cortex to have significant blood flow. The estimated current dipole strengths of somatosensory evoked fields from median nerve stimulation correlated significantly (r = 0.95, P graphesthesia). The combination of evoked magnetic field recording and magnetic resonance imaging is a promising non-invasive technology for studying brain function in patients with cerebrovascular disease.

  19. Baroreceptor activation attenuates attentional effects on pain-evoked potentials.

    Science.gov (United States)

    Gray, Marcus A; Minati, Ludovico; Paoletti, Giulia; Critchley, Hugo D

    2010-12-01

    Focused attention typically enhances neural nociceptive responses, reflected electroencephalographically as increased amplitude of pain-evoked event-related potentials (ERPs). Additionally, pain-evoked ERPs are attenuated by hypertension and baroreceptor activity, through as yet unclear mechanisms. There is indirect evidence that these two effects may interact, suggesting that baroreceptor-related modulation of nociception is more than a low-level gating phenomenon. To address this hypothesis, we explored in a group of healthy participants the combined effects of cue-induced expectancy and baroreceptor activity on the amplitude of pain-evoked ERPs. Brief nociceptive skin stimuli were delivered during a simple visual task; half were preceded by a visual forewarning cue, and half were unpredictable. Nociceptive stimuli were timed to coincide either with systole (maximum activation of cardiac baroreceptors) or with diastole (minimum baroreceptor activation). We observed a strong interaction between expectancy and cardiac timing for the amplitude of the P2 ERP component; no effects were observed for the N2 component. Cued stimuli were associated with larger P2 amplitude, but this effect was abolished for stimuli presented during baroreceptor activation. No cardiac timing effect was observed for un-cued stimuli. Taken together, these findings suggest a close integration of cognitive-affective aspects of expectancy and baroreceptor influences on pain, and as such may cast further light on mechanisms underlying mental and physiological contributions to clinical pain.

  20. Optical suppression of drug-evoked phasic dopamine release.

    Science.gov (United States)

    McCutcheon, James E; Cone, Jackson J; Sinon, Christopher G; Fortin, Samantha M; Kantak, Pranish A; Witten, Ilana B; Deisseroth, Karl; Stuber, Garret D; Roitman, Mitchell F

    2014-01-01

    Brief fluctuations in dopamine concentration (dopamine transients) play a key role in behavior towards rewards, including drugs of abuse. Drug-evoked dopamine transients may result from actions at both dopamine cell bodies and dopamine terminals. Inhibitory opsins can be targeted to dopamine neurons permitting their firing activity to be suppressed. However, as dopamine transients can become uncoupled from firing, it is unknown whether optogenetic hyperpolarization at the level of the soma is able to suppress dopamine transients. Here, we used in vivo fast-scan cyclic voltammetry to record transients evoked by cocaine and raclopride in nucleus accumbens (NAc) of urethane-anesthetized rats. We targeted halorhodopsin (NpHR) specifically to dopamine cells by injecting Cre-inducible virus into ventral tegmental area (VTA) of transgenic rats that expressed Cre recombinase under control of the tyrosine hydroxylase promoter (TH-Cre(+) rats). Consistent with previous work, co-administration of cocaine and raclopride led to the generation of dopamine transients in NAc shell. Illumination of VTA with laser strongly suppressed the frequency of transients in NpHR-expressing rats, but not in control rats. Laser did not have any effect on amplitude of transients. Thus, optogenetics can effectively reduce the occurrence of drug-evoked transients and is therefore a suitable approach for studying the functional role of such transients in drug-associated behavior.

  1. Optical suppression of drug-evoked phasic dopamine release

    Directory of Open Access Journals (Sweden)

    James Edgar Mccutcheon

    2014-09-01

    Full Text Available Brief fluctuations in dopamine concentration (dopamine transients play a key role in behavior towards rewards, including drugs of abuse. Drug-evoked dopamine transients may result from actions at both dopamine cell bodies and dopamine terminals. Inhibitory opsins can be targeted to dopamine neurons permitting their firing activity to be suppressed. However, as dopamine transients can become uncoupled from firing, it is unknown whether optogenetic hyperpolarization at the level of the soma is able to suppress dopamine transients. Here, we used in vivo fast-scan cyclic voltammetry to record transients evoked by cocaine and raclopride in nucleus accumbens (NAc of urethane-anesthetized rats. We targeted halorhodopsin (NpHR specifically to dopamine cells by injecting Cre-inducible virus into ventral tegmental area (VTA of transgenic rats that expressed Cre recombinase under control of the tyrosine hydroxylase promoter (TH-Cre+ rats. Consistent with previous work, co-administration of cocaine and raclopride led to the generation of dopamine transients in NAc shell. Illumination of VTA with laser strongly suppressed the frequency of transients in NpHR-expressing rats, but not in control rats. Laser did not have any effect on amplitude of transients. Thus, optogenetics can effectively reduce the occurrence of drug-evoked transients and is therefore a suitable approach for studying the functional role of such transients in drug-associated behavior.

  2. Helicon plasma thruster discharge model

    Energy Technology Data Exchange (ETDEWEB)

    Lafleur, T., E-mail: trevor.lafleur@lpp.polytechnique.fr [Laboratoire de Physique des Plasmas, CNRS, Sorbonne Universités, UPMC Univ Paris 06, Univ Paris-Sud, Ecole Polytechnique, 91128 Palaiseau, France and ONERA - The French Aerospace Lab, 91120 Palaiseau (France)

    2014-04-15

    By considering particle, momentum, and energy balance equations, we develop a semi-empirical quasi one-dimensional analytical discharge model of radio-frequency and helicon plasma thrusters. The model, which includes both the upstream plasma source region as well as the downstream diverging magnetic nozzle region, is compared with experimental measurements and confirms current performance levels. Analysis of the discharge model identifies plasma power losses on the radial and back wall of the thruster as the major performance reduction factors. These losses serve as sinks for the input power which do not contribute to the thrust, and which reduce the maximum plasma density and hence propellant utilization. With significant radial plasma losses eliminated, the discharge model (with argon) predicts specific impulses in excess of 3000 s, propellant utilizations above 90%, and thruster efficiencies of about 30%.

  3. Capillary Discharge XUV Radiation Source

    Directory of Open Access Journals (Sweden)

    M. Nevrkla

    2009-01-01

    Full Text Available A device producing Z-pinching plasma as a source of XUV radiation is described. Here a ceramic capacitor bank pulse-charged up to 100 kV is discharged through a pre-ionized gas-filled ceramic tube 3.2 mm in diameter and 21 cm in length. The discharge current has amplitude of 20 kA and a rise-time of 65 ns. The apparatus will serve as experimental device for studying of capillary discharge plasma, for testing X-ray optics elements and for investigating the interaction of water-window radiation with biological samples. After optimization it will be able to produce 46.9 nm laser radiation with collision pumped Ne-like argon ions active medium. 

  4. Stroke rehabilitation and discharge planning.

    Science.gov (United States)

    Kerr, Peter

    Nurses play a pivotal role in the rehabilitation and discharge planning process of patients who have had a stroke. The nurse's role in the wider stroke multidisciplinary team is complex and diverse and, as such, stroke nurses may find it hard to describe their role and how it fits into the rehabilitation and discharge planning process. A definition of the stroke nurse role in prominent publications such as those of the Scottish Intercollegiate Guidelines Network and the Royal College of Physicians is lacking. This article emphasises the role of the stroke nurse in the rehabilitation and discharge planning process in the stroke unit, while highlighting the complexity, diversity and importance of this role in providing holistic care and support for patients who have survived a stroke. The author draws on his clinical experience of stroke nursing practice in primary, secondary and tertiary care in west central Scotland.

  5. Human sensory-evoked responses differ coincident with either "fusion-memory" or "flash-memory", as shown by stimulus repetition-rate effects

    Directory of Open Access Journals (Sweden)

    Baird Bill

    2006-02-01

    Full Text Available Abstract Background: A new method has been used to obtain human sensory evoked-responses whose time-domain waveforms have been undetectable by previous methods. These newly discovered evoked-responses have durations that exceed the time between the stimuli in a continuous stream, thus causing an overlap which, up to now, has prevented their detection. We have named them "A-waves", and added a prefix to show the sensory system from which the responses were obtained (visA-waves, audA-waves, somA-waves. Results: When A-waves were studied as a function of stimulus repetition-rate, it was found that there were systematic differences in waveshape at repetition-rates above and below the psychophysical region in which the sensation of individual stimuli fuse into a continuity. The fusion phenomena is sometimes measured by a "Critical Fusion Frequency", but for this research we can only identify a frequency-region [which we call the STZ (Sensation-Transition Zone]. Thus, the A-waves above the STZ differed from those below the STZ, as did the sensations. Study of the psychophysical differences in auditory and visual stimuli, as shown in this paper, suggest that different stimulus features are detected, and remembered, at stimulation rates above and below STZ. Conclusion: The results motivate us to speculate that: 1 Stimulus repetition-rates above the STZ generate waveforms which underlie "fusion-memory" whereas rates below the STZ show neuronal processing in which "flash-memory" occurs. 2 These two memories differ in both duration and mechanism, though they may occur in the same cell groups. 3 The differences in neuronal processing may be related to "figure" and "ground" differentiation. We conclude that A-waves provide a novel measure of neural processes that can be detected on the human scalp, and speculate that they may extend clinical applications of evoked response recordings. If A-waves also occur in animals, it is likely that A-waves will provide

  6. A tomographic visualization of electric discharge sound fields in atmospheric pressure plasma using laser diffraction

    Science.gov (United States)

    Nakamiya, Toshiyuki; Mitsugi, Fumiaki; Iwasaki, Yoichiro; Ikegami, Tomoaki; Tsuda, Ryoichi; Sonoda, Yoshito; Danuta Stryczewska, Henryka

    2013-02-01

    The phase modulation of transparent gas can be detected using Fraunhofer diffraction technique, which we call optical wave microphone (OWM). The OWM is suitable for the detection of sonic wave from audible sound to ultrasonic wave. Because this technique has no influence on sound field or electric field during the measurement, we have applied it to the sound detection for the electric discharges. There is almost no research paper that uses the discharge sound to examine the electrical discharge phenomenon. Two-dimensional visualization of the sound field using the OWM is also possible when the computerized tomography (CT) is combined. In this work, coplanar dielectric barrier discharge sin different gases of Ar, N2, He were characterized via the OWM as well as applied voltage and discharge current. This is the first report to investigate the influence of the type of the atmospheric gas on the two-dimensional sound field distribution for the coplanar dielectric barrier discharge using the OWM with CT. Contribution to the Topical Issue "13th International Symposium on High Pressure Low Temperature Plasma Chemistry (Hakone XIII)", Edited by Nicolas Gherardi, Henryca Danuta Stryczewska and Yvan Ségui.

  7. Wave Dragon

    DEFF Research Database (Denmark)

    Tedd, James; Kofoed, Jens Peter; Friis-Madsen, Erik

    2008-01-01

    Since March 2003 a prototype of Wave Dragon has been tested in an inland sea in Denmark. This has been a great success with all subsystems tested and improved through working in an offshore environment. The project has proved the Wave Dragon device and has enabled the next stage, a production sized...

  8. Wave Dragon

    DEFF Research Database (Denmark)

    Tedd, James; Kofoed, Jens Peter; Friis-Madsen, Erik;

    2008-01-01

    Since March 2003 a prototype of Wave Dragon has been tested in an inland sea in Denmark. This has been a great success with all subsystems tested and improved through working in an offshore environment. The project has proved the Wave Dragon device and has enabled the next stage, a production sized...

  9. Wave Star

    DEFF Research Database (Denmark)

    Kramer, Morten; Brorsen, Michael; Frigaard, Peter

    Nærværende rapport beskriver numeriske beregninger af den hydrodynamiske interaktion mellem 5 flydere i bølgeenergianlægget Wave Star.......Nærværende rapport beskriver numeriske beregninger af den hydrodynamiske interaktion mellem 5 flydere i bølgeenergianlægget Wave Star....

  10. Excitation of surface plasma waves over corrugated slow-wave structure

    Indian Academy of Sciences (India)

    Ashim P Jain; Jetendra Parashar

    2005-08-01

    A microwave propagating along vacuum–dielectric–plasma interface excites surface plasma wave (SPW). A periodic slow-wave structure placed over dielectric slows down the SPW. The phase velocity of slow SPW is sensitive to height, periodicity, number of periods, thickness and the separation between dielectric and slow-wave structure. These slow SPW can couple the microwave energy to the plasma and can sustain the discharge. The efficiency of the power coupling is few per cent and is sensitive to separation between dielectric and slow-wave structure.

  11. Prognosis in prolonged coma patients with diffuse axonal injury assessed by somatosensory evoked potential

    Institute of Scientific and Technical Information of China (English)

    Xiujue Zheng; Mantao Chen; Jingqi Li; Fei Cao

    2013-01-01

    A total of 43 prolonged coma patients with diffuse axonal injury received the somatosensory evoked potential examination one month after injury in the First Affiliated Hospital, School of Medicine, Zhejiang University in China. Somatosensory evoked potentials were graded as normal, abnormal or absent (grades I–III) according to N20 amplitude and central conduction time. The outcome in patients with grade III somatosensory evoked potential was in each case unfavorable. The prognostic accuracy of grade III somatosensory evoked potential for unfavorable and non-awakening outcome was 100% and 80%, respectively. The prognostic accuracy of grade I somatosensory evoked potential for favorable and wakening outcome was 86% and 100%, respectively. These results suggest that somatosensory evoked potential grade is closely correlated with coma severity and degree of recovery. Somatosensory evoked potential is a valuable diagnostic tool to assess prognosis in prolonged coma patients with diffuse axonal injury.

  12. A joint sparse representation-based method for double-trial evoked potentials estimation.

    Science.gov (United States)

    Yu, Nannan; Liu, Haikuan; Wang, Xiaoyan; Lu, Hanbing

    2013-12-01

    In this paper, we present a novel approach to solving an evoked potentials estimating problem. Generally, the evoked potentials in two consecutive trials obtained by repeated identical stimuli of the nerves are extremely similar. In order to trace evoked potentials, we propose a joint sparse representation-based double-trial evoked potentials estimation method, taking full advantage of this similarity. The estimation process is performed in three stages: first, according to the similarity of evoked potentials and the randomness of a spontaneous electroencephalogram, the two consecutive observations of evoked potentials are considered as superpositions of the common component and the unique components; second, making use of their characteristics, the two sparse dictionaries are constructed; and finally, we apply the joint sparse representation method in order to extract the common component of double-trial observations, instead of the evoked potential in each trial. A series of experiments carried out on simulated and human test responses confirmed the superior performance of our method.

  13. State Waste Discharge Permit application, 183-N Backwash Discharge Pond

    Energy Technology Data Exchange (ETDEWEB)

    1994-06-01

    As part of the Hanford Federal Facility Agreement and Consent Order negotiations (Ecology et al. 1994), the US Department of Energy, Richland Operations Office, the US Environmental Protection Agency, and the Washington State Department of Ecology agreed that liquid effluent discharges to the ground on the Hanford Site which affect groundwater or have the potential to affect groundwater would be subject to permitting under the structure of Chapter 173--216 (or 173--218 where applicable) of the Washington Administrative Code, the State Waste Discharge Permit Program. As a result of this decision, the Washington State Department of Ecology and the US Department of Energy, Richland Operations Office entered into Consent Order No. DE91NM-177, (Ecology and DOE-RL 1991). The Consent Order No. DE91NM-177 requires a series of permitting activities for liquid effluent discharges. Liquid effluents on the Hanford Site have been classified as Phase I, Phase II, and Miscellaneous Streams. The Consent Order No. DE91NM-177 establishes milestones for State Waste Discharge Permit application submittals for all Phase I and Phase II streams, as well as the following 11 Miscellaneous Streams as identified in Table 4 of the Consent Order No. DE91NM-177.

  14. [Evoked potentials in movement epilepsy (a report on 4 observations) (author's transl)].

    Science.gov (United States)

    Paty, J; Deliac-Narvarte, M M; Fontan, D; Loiseau, P

    1978-09-01

    A study of evoked potentials; visual (V.E.P.) auditory (A.E.P), and somatosensorial (S.E.P.) in 4 cases of movement epilepsy. Their correlation to clinical findings (provoking factors, control of the attacks), electroencephalographic and neuroradiological (scanner) data, shows that two types of information can be obtained: lesional and functional. Three types of modification can be described: a) the topographically limited changes in E.P. depend on lesional localization; b) the increase in amplitude of the late components and of the post-discharge of the E.P. ("paroxystical" aspect) appear to be a characteristic common to all epilepsies, whatever the mechanism; c) the abnormal exaggeration of the E.P. during voluntary movement seems to be a dynamic element peculiar to movement epilepsy. The information given by E.P.'s in some well-defined cases of epilepsy suggest that it is possible to draw conclusions from tests of the capacity for sensory-motor control to enable functional therapy of some attacks.

  15. Tibial somatosensory evoked potential can prognosticate for ambulatory function in subacute hemiplegic stroke.

    Science.gov (United States)

    Hwang, Pyoungsik; Sohn, Min Kyun; Kim, Cuk-Seong; Jee, Sungju

    2016-04-01

    Early prediction of expected recovery in stroke can help in planning appropriate medical and rehabilitation interventions. Recovery of ambulation is one of the essential endpoints in stroke rehabilitation. However, the correlation of somatosensory evoked potentials (SSEP) with clinical parameters and their predictive significance are not clearly defined. We aimed to examine the association between tibial nerve SSEP and ambulatory outcomes in subacute hemiplegic stroke patients. We reviewed medical records for hemiplegic patients with first-ever stroke who received inpatient rehabilitation from January 2009 to May 2013. We excluded patients with diabetes mellitus, quadriplegia, bilateral lesions, brainstem lesions, those aged over 80 years, and those with severe musculoskeletal problems. Tibial nerve SSEP were performed when they were transferred to the rehabilitation department. SSEP findings were divided into three groups; normal, abnormal and absent response. Berg balance scale and functional ambulation category (FAC) at discharge were compared with initial tibial SSEP findings using one-way analysis of variance. Thirty-one hemiplegic patients were included. Berg balance scale and FAC were significantly different according to the SSEP (Phemiplegic patients.

  16. Compact monolithic capacitive discharge unit

    Science.gov (United States)

    Roesler, Alexander W.; Vernon, George E.; Hoke, Darren A.; De Marquis, Virginia K.; Harris, Steven M.

    2007-06-26

    A compact monolithic capacitive discharge unit (CDU) is disclosed in which a thyristor switch and a flyback charging circuit are both sandwiched about a ceramic energy storage capacitor. The result is a compact rugged assembly which provides a low-inductance current discharge path. The flyback charging circuit preferably includes a low-temperature co-fired ceramic transformer. The CDU can further include one or more ceramic substrates for enclosing the thyristor switch and for holding various passive components used in the flyback charging circuit. A load such as a detonator can also be attached directly to the CDU.

  17. Wave Solutions

    CERN Document Server

    Christov, Ivan C

    2012-01-01

    In classical continuum physics, a wave is a mechanical disturbance. Whether the disturbance is stationary or traveling and whether it is caused by the motion of atoms and molecules or the vibration of a lattice structure, a wave can be understood as a specific type of solution of an appropriate mathematical equation modeling the underlying physics. Typical models consist of partial differential equations that exhibit certain general properties, e.g., hyperbolicity. This, in turn, leads to the possibility of wave solutions. Various analytical techniques (integral transforms, complex variables, reduction to ordinary differential equations, etc.) are available to find wave solutions of linear partial differential equations. Furthermore, linear hyperbolic equations with higher-order derivatives provide the mathematical underpinning of the phenomenon of dispersion, i.e., the dependence of a wave's phase speed on its wavenumber. For systems of nonlinear first-order hyperbolic equations, there also exists a general ...

  18. Dielectric barrier discharges in analytical chemistry.

    Science.gov (United States)

    Meyer, C; Müller, S; Gurevich, E L; Franzke, J

    2011-06-21

    The present review reflects the importance of dielectric barrier discharges in analytical chemistry. Special about this discharge is-and in contrast to usual discharges with direct current-that the plasma is separated from one or two electrodes by a dielectric barrier. This gives rise to two main features of the dielectric barrier discharges; it can serve as dissociation and excitation device and as ionization mechanism, respectively. The article portrays the various application fields for dielectric barrier discharges in analytical chemistry, for example the use for elemental detection with optical spectrometry or as ionization source for mass spectrometry. Besides the introduction of different kinds of dielectric barrier discharges used for analytical chemistry from the literature, a clear and concise classification of dielectric barrier discharges into capacitively coupled discharges is provided followed by an overview about the characteristics of a dielectric barrier discharge concerning discharge properties and the ignition mechanism.

  19. Formation and dynamics of nano-particles in a stratified spherical glow discharge

    Science.gov (United States)

    Sakhapov, S. Z.; Fedoseev, A. V.; Sukhinin, G. I.; Novopashin, S. A.

    2015-04-01

    The formation of clouds of dust nano-particles in a spherical dc glow discharge in ethanol was observed. Nano-particles were formed in a process of coagulation of ethanol dissociation products in a plasma of gas discharge. During the process the particles were captured into clouds in the electric potential wells of the strong striations of a spherical discharge. Periodically, the cloud of nano-particles experienced some sudden instability (explosion), and started to move to the cathode at high velocity. It was proved that the velocity of the particle clouds was an exponentially decaying function of time as in the case of dissipative dust solitary waves.

  20. High-pressure discharges with imposed stability resulting in reduced power requirements

    Science.gov (United States)

    Brooks, N. H.; Jensen, T. H.; Moeller, C. M.

    2003-08-01

    High-pressure plasma discharge columns that are long and straight, as well as uniform in the axial direction, have been generated in a steady state. These discharges, stabilized by rotation of the containment envelope about a horizontal axis, have reduced heat transport to the wall due to the absence of buoyancy-driven radial convection and the elimination of eddies caused by sheared flow. These "rotating tube discharges" may take the form of electric arcs powered with dc or low-frequency ac; or of electrodeless plasmas, heated by electromagnetic waves at rf or microwave frequencies.

  1. Investigation of electrolyte electric discharge characteristics

    Science.gov (United States)

    Kirko, D. L.; Savjolov, A. S.

    2016-09-01

    The most important electrical characteristics of electrolyte electric discharge were investigated. The electric burning discharge was obtained with the help of different electrolytes. The spectral composition of the electric discharge electromagnetic radiation was determined, the plasma temperature was determined. The spectrum of the electric discharge high-frequency oscillations was calculated in the region v=10 kHz-80 MHz. The most appropriate modes of the electric burning discharge in different electrolytes were proposed.

  2. Coalescence of deep and superficial epileptic foci into larger discharge units in adult rat neocortex.

    Science.gov (United States)

    Serafini, Ruggero; Andrade, Rodrigo; Loeb, Jeffrey A

    2015-04-30

    Epilepsy is a disease of neuronal hyper-synchrony that can involve both neocortical and hippocampal brain regions. While much is known about the network properties of the hippocampus little is known of how epileptic neocortical hyper-synchrony develops. We aimed at characterizing the properties of epileptic discharges of a neocortical epileptic focus. We established a multi-electrode-array method to record the spatial patterns of epileptiform potentials in acute adult rat brain slices evoked by 4-Aminopyridine in the absence of magnesium. Locations of discharges mapped to two anatomical regions over the somatosensory cortex and over the lateral convexity separated by a gap at a location matching the dysgranular zone. Focal epileptiform discharges were recorded in superficial and deep neocortical layers but over superficial layers, they exhibited larger surface areas. They were often independent even when closely spaced to one another but they became progressively coupled resulting in larger zones of coherent discharge. The gradual coupling of multiple, independent, closely spaced, spatially restricted, focal discharges between deep and superficial neocortical layers represents a possible mechanism of the development of an epileptogenic zone.

  3. COALESCENCE OF DEEP AND SUPERFICIAL EPILEPTIC FOCI INTO LARGER DISCHARGE UNITS IN ADULT RAT NEOCORTEX

    Science.gov (United States)

    SERAFINI, RUGGERO; ANDRADE, RODRIGO; LOEB, JEFFREY A.

    2016-01-01

    Epilepsy is a disease of neuronal hyper-synchrony that can involve both neocortical and hippocampal brain regions. While much is known about the network properties of the hippocampus little is known of how epileptic neocortical hyper-synchrony develops. We aimed at characterizing the properties of epileptic discharges of a neocortical epileptic focus. We established a multi-electrode-array method to record the spatial patterns of epileptiform potentials in acute adult rat brain slices evoked by 4-Aminopyridine in the absence of magnesium. Locations of discharges mapped to two anatomical regions over the somatosensory cortex and over the lateral convexity separated by a gap at a location matching the dysgranular zone. Focal epileptiform discharges were recorded in superficial and deep neocortical layers but over superficial layers, they exhibited larger surface areas. They were often independent even when closely spaced to one another but they became progressively coupled resulting in larger zones of coherent discharge. The gradual coupling of multiple, independent, closely spaced, spatially restricted, focal discharges between deep and superficial neocortical layers represents a possible mechanism of the development of an epileptogenic zone. PMID:25701714

  4. Wave overtopping resistance of grassed dike slopes in Vietnam

    NARCIS (Netherlands)

    Trung, L.H.; Van der Meer, J.W.; Luong, N.Q.; Verhagen, H.J.; Schiereck, G.J.

    2011-01-01

    The resistance of various grassed slopes against wave overtopping has been appraised by means of the Wave Overtopping Simulator in situ for a couple of years in Viet Nam. Destructive test results show that a dike slope covered with grass could suffer a certain overtopping discharge not smaller than

  5. Wave overtopping resistance of grassed dike slopes in Vietnam

    NARCIS (Netherlands)

    Trung, L.H.; Van der Meer, J.W.; Luong, N.Q.; Verhagen, H.J.; Schiereck, G.J.

    2011-01-01

    The resistance of various grassed slopes against wave overtopping has been appraised by means of the Wave Overtopping Simulator in situ for a couple of years in Viet Nam. Destructive test results show that a dike slope covered with grass could suffer a certain overtopping discharge not smaller than

  6. Wave Overtopping of Marine Structures

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter

    defense structures. Optimization of structures utilizing wave overtopping for the production of electrical power has been ongoing throughout the last decade. It has been established that the information available in the existing literature is insufficient to describe overtopping of such structures......During the past 50 years tools for predicting wave overtopping of sea defense structures have continuously been refined. However, developers of wave energy converters have raised questions about how to predict the overtopping of structures with layouts significantly different from those of sea....... The present thesis describes investigations conducted against this background. The development of guidelines for calculating overtopping discharges for a wide variety of slope layouts is presented. Both structures with single and multi level reservoirs are examined. All geometries have been subjected...

  7. Waves, damped wave and observation

    CERN Document Server

    Phung, Kim Dang

    2009-01-01

    We consider the wave equation in a bounded domain (eventually convex). Two kinds of inequality are described when occurs trapped ray. Applications to control theory are given. First, we link such kind of estimate with the damped wave equation and its decay rate. Next, we describe the design of an approximate control function by an iterative time reversal method.

  8. Four weeks' inhalation exposure of Long Evans rats to 4-tert-butyltoluene: Effect on evoked potentials, behaviour and brain neurochemistry

    DEFF Research Database (Denmark)

    Lam, Henrik Rye; Ladefoged, Ole; Østergaard, Grete

    2000-01-01

    Long-lasting central nervous system (CNS) neurotoxicity of 4-tert-butyltoluene (TBT) has been investigated using electrophysiology, behaviour, and neurochemistry in Long Evans rats exposed by inhalation to 0, 20, or 40 p.p.m. TBT 6 hr/day, 7 days/week for 4 weeks. Flash evoked potentials...... and somatosensory evoked potentials were not affected by TBT In Auditory Brain Stem Response there was no shift in hearing threshold, but the amplitude of the first wave was increased in both exposed groups at high stimulus levels. Three to four months after the end of exposure, behavioural studies in Morris water...... maze and eight-arm maze failed to demonstrate any TBT induced effects. Exposure was followed by a 5 months exposure-free period prior to gross regional and subcellular (synaptosomal) neurochemical investigations of the brain. TBT reduced the NA concentration in whole brain minus cerebellum...

  9. Electronic Discharge Letter Mobile App

    NARCIS (Netherlands)

    Lezcano, Leonardo; Triana, Michel; Ternier, Stefaan; Hartkopf, Kathleen; Stieger, Lina; Schroeder, Hanna; Sopka, Sasa; Drachsler, Hendrik; Maher, Bridget; Henn, Patrick; Orrego, Carola; Marcus, Specht

    2014-01-01

    The electronic discharge letter mobile app takes advantage of Near Field Communication (NFC) within the PATIENT project and a related post-doc study. NFC enabled phones to read passive RFID tags, but can also use this short-range wireless technology to exchange (small) messages. NFC in that sense co

  10. Plasma Characteristics of Electrosurgical Discharges*

    Science.gov (United States)

    Stalder, Kenneth R.

    2003-10-01

    Surgical devices utilizing electrical discharges of ever increasing sophistication have been used for decades for numerous procedures. Cushing and Bovie in 1928, for example, developed high-frequency spark generators to cauterize blood vessels and remove unwanted tissue by a thermal ablation processes. Modern Bovies (named after their inventor) use a high-frequency discharge from an electrode to nearby tissue to thermally ablate tissue. Spectroscopic analysis shows that these discharges are hot and are well represented by a thermal equilibrium model, and temperatures near 2000 K are easily achieved. New electrosurgical devices utilizing repetitive electrical discharges in a conducting saline environment have recently been developed. Electron emission from an active electrode during certain portions of the voltage waveform causes the formation of a vapor layer surrounding the electrode and the subsequent ionization and dissociation of species in this region. Electron temperatures of approximately 4 eV are achieved during the plasma phase. Water molecules are dissociated into reactive fragments, and the salt species are also excited and ionized in this nonequilibrium plasma. It is thought that the reactive species interact with nearby tissue, causing localized tissue removal (ablation) which surgeons can exploit during surgical procedures. Flowing saline surrounding the plasma region cools untargeted tissue and removes the reaction products. This presentation will focus on experimental results of the plasma conditions and discuss our current efforts to understand the complex reactions of the various plasma species with tissue structures such as collagen. A short clip showing tissue removal will also be shown.

  11. Electrical discharge machining in dentistry.

    Science.gov (United States)

    Van Roekel, N B

    1992-01-01

    A brief history of electrical discharge machining (EDM) is given and the process is discussed. A description of the application of EDM for fabricating precision attachment removable partial dentures, fixed-removable implant prostheses, and titanium-ceramic crowns is presented. The advantages and disadvantages of the EDM process for the dental profession are evaluated. Although expensive, the procedure has merit.

  12. Gravity waves

    Science.gov (United States)

    Fritts, David

    1987-02-01

    Gravity waves contributed to the establishment of the thermal structure, small scale (80 to 100 km) fluctuations in velocity (50 to 80 m/sec) and density (20 to 30%, 0 to peak). Dominant gravity wave spectrum in the middle atmosphere: x-scale, less than 100 km; z-scale, greater than 10 km; t-scale, less than 2 hr. Theorists are beginning to understand middle atmosphere motions. There are two classes: Planetary waves and equatorial motions, gravity waves and tidal motions. The former give rise to variability at large scales, which may alter apparent mean structure. Effects include density and velocity fluctuations, induced mean motions, and stratospheric warmings which lead to the breakup of the polar vortex and cooling of the mesosphere. On this scale are also equatorial quasi-biennial and semi-annual oscillations. Gravity wave and tidal motions produce large rms fluctuations in density and velocity. The magnitude of the density fluctuations compared to the mean density is of the order of the vertical wavelength, which grows with height. Relative density fluctuations are less than, or of the order of 30% below the mesopause. Such motions may cause significant and variable convection, and wind shear. There is a strong seasonal variation in gravity wave amplitude. Additional observations are needed to address and quantify mean and fluctuation statistics of both density and mean velocity, variability of the mean and fluctuations, and to identify dominant gravity wave scales and sources as well as causes of variability, both temporal and geographic.

  13. Source analysis of short and long latency vestibular-evoked potentials (VsEPs) produced by left vs. right ear air-conducted 500 Hz tone pips.

    Science.gov (United States)

    Todd, N P M; Paillard, A C; Kluk, K; Whittle, E; Colebatch, J G

    2014-06-01

    Todd et al. (2014) have recently demonstrated the presence of vestibular dependent changes both in the morphology and in the intensity dependence of auditory evoked potentials (AEPs) when passing through the vestibular threshold as determined by vestibular evoked myogenic potentials (VEMPs). In this paper we extend this work by comparing left vs. right ear stimulation and by conducting a source analysis of the resulting evoked potentials of short and long latency. Ten healthy, right-handed subjects were recruited and evoked potentials were recorded to both left- and right-ear sound stimulation, above and below vestibular threshold. Below VEMP threshold, typical AEPs were recorded, consisting of mid-latency (MLR) waves Na and Pa followed by long latency AEPs (LAEPs) N1 and P2. In the supra-threshold condition, the expected changes in morphology were observed, consisting of: (1) short-latency vestibular evoked potentials (VsEPs) which have no auditory correlate, i.e. the ocular VEMP (OVEMP) and inion response related potentials; (2) a later deflection, labelled N42/P52, followed by the LAEPs N1 and P2. Statistical analysis of the vestibular dependent responses indicated a contralateral effect for inion related short-latency responses and a left-ear/right-hemisphere advantage for the long-latency responses. Source analysis indicated that the short-latency effects may be mediated by a contralateral projection to left cerebellum, while the long-latency effects were mediated by a contralateral projection to right cingulate cortex. In addition we found evidence of a possible vestibular contribution to the auditory T-complex in radial temporal lobe sources. These last results raise the possibility that acoustic activation of the otolith organs could potentially contribute to auditory processing.

  14. Wave Dragon

    DEFF Research Database (Denmark)

    Tedd, James; Kofoed, Jens Peter; Knapp, W.

    2006-01-01

    Wave Dragon is a floating wave energy converter working by extracting energy principally by means of overtopping of waves into a reservoir. A 1:4.5 scale prototype has been sea tested for 20 months. This paper presents results from testing, experiences gained and developments made during...... this extended period. The prototype is highly instrumented. The overtopping characteristic and the power produced are presented here. This has enabled comparison between the prototype and earlier results from both laboratory model and computer simulation. This gives the optimal operating point and the expected...

  15. Terrestrial propagation of long electromagnetic waves

    CERN Document Server

    Galejs, Janis; Fock, V A

    2013-01-01

    Terrestrial Propagation of Long Electromagnetic Waves deals with the propagation of long electromagnetic waves confined principally to the shell between the earth and the ionosphere, known as the terrestrial waveguide. The discussion is limited to steady-state solutions in a waveguide that is uniform in the direction of propagation. Wave propagation is characterized almost exclusively by mode theory. The mathematics are developed only for sources at the ground surface or within the waveguide, including artificial sources as well as lightning discharges. This volume is comprised of nine chapte

  16. Quasi-DC electrical discharge characterization in a supersonic flow

    Science.gov (United States)

    Houpt, Alec; Hedlund, Brock; Leonov, Sergey; Ombrello, Timothy; Carter, Campbell

    2017-04-01

    A Quasi-DC (Q-DC) electrical discharge generates a highly transient filamentary plasma in high-speed airflow. Major specific properties of this type of discharge are realized due to a strong coupling of the plasma to the moving gas. The plasma, supplied by a DC voltage waveform, demonstrates a pulsed-periodic pattern of dynamics significantly affecting the flow structure. In this study, the dynamics and plasma parameters of the Q-DC discharge are analyzed in the Supersonic Test Rig (SBR-50) at the University of Notre Dame at Mach number M = 2, stagnation pressure P 0 = (0.9-2.6) × 105 Pa, stagnation temperature T 0 = 300 K, unit Reynolds number ReL = 7-25 × 106 m-1, and plasma power W pl = 3-21 kW. The plasma parameters are measured with current-voltage probes and optical emission spectroscopy. An unsteady pattern of interaction is depicted by high-speed image capturing. The result of the plasma-flow interaction is characterized by means of pressure measurements and schlieren visualization. It is considered that the Q-DC discharge may be employed for active control of duct-driven flows, cavity-based flow, and for effective control of shock wave-boundary layer interaction.

  17. Progress of long pulse discharges by ECH in LHD

    Science.gov (United States)

    Yoshimura, Y.; Kasahara, H.; Tokitani, M.; Sakamoto, R.; Ueda, Y.; Ito, S.; Okada, K.; Kubo, S.; Shimozuma, T.; Igami, H.; Takahashi, H.; Tsujimura, T. I.; Makino, R.; Kobayashi, S.; Mizuno, Y.; Akiyama, T.; Ashikawa, N.; Masuzaki, S.; Motojima, G.; Shoji, M.; Suzuki, C.; Tanaka, H.; Tanaka, K.; Tokuzawa, T.; Tsuchiya, H.; Yamada, I.; Goto, Y.; Yamada, H.; Mutoh, T.; Komori, A.; Takeiri, Y.; the LHD Experiment Group

    2016-04-01

    Using ion cyclotron heating and electron cyclotron heating (ECH), or solo ECH, trials of steady state plasma sustainment have been conducted in the superconducting helical/stellarator, large helical device (LHD) (Ida K et al 2015 Nucl. Fusion 55 104018). In recent years, the ECH system has been upgraded by applying newly developed 77 and 154 GHz gyrotrons. A new gas fueling system applied to the steady state operations in the LHD realized precise feedback control of the line average electron density even when the wall condition varied during long pulse discharges. Owing to these improvements in the ECH and the gas fueling systems, a stable 39 min discharge with a line average electron density n e_ave of 1.1  ×  1019 m-3, a central electron temperature T e0 of over 2.5 keV, and a central ion temperature T i0 of 1.0 keV was successfully performed with ~350 kW EC-waves. The parameters are much improved from the previous 65 min discharge with n e_ave of 0.15  ×  1019 m-3 and T e0 of 1.7 keV, and the 30 min discharge with n e_ave of 0.7  ×  1019 m-3 and T e0 of 1.7 keV.

  18. Imaging calcium waves in cerebellar Bergmann glia.

    Science.gov (United States)

    Beierlein, Michael

    2013-01-01

    This protocol describes methods for recording synaptically evoked Ca(2+) waves from individual Bergmann glia (BG) in slices of cerebellar cortex. Unlike protoplasmic, star-shaped astrocytes, whose thin processes pose a serious challenge to stable Ca(2+) measurements, BG are large radial cells, with several main processes that run over distances of several hundred micrometers toward the pia and ensheathe thousands of parallel fiber (PF) synapses. Stimulation of PF synapses with brief bursts can trigger long-lasting Ca(2+) responses in BG processes, which can be reliably recorded using a cooled charge-coupled device (CCD) camera. This protocol was developed to enable measurements of Ca(2+) waves in individual BG loaded with a high-affinity Ca(2+) indicator such as Fura-2 for up to 2 h. Because BG recorded in slices rarely display spontaneous (i.e., tetrodotoxin [TTX]-sensitive) or intrinsic Ca(2+) transients, Ca(2+) waves can be evoked repeatedly and reliably, which permits quantitative studies using pharmacological tools. Fluorescence measurements obtained using CCD technology offer a straightforward means of characterizing the mechanisms and potential functional consequences of widespread and long-lasting, store-mediated Ca(2+) increases in astrocytes.

  19. Janus Waves

    CERN Document Server

    Papazoglou, Dimitris G; Tzortzakis, Stelios

    2016-01-01

    We show the existence of a family of waves that share a common interesting property affecting the way they propagate and focus. These waves are a superposition of twin waves, which are conjugate to each other under inversion of the propagation direction. In analogy to holography, these twin "real" and "virtual" waves are related respectively to the converging and the diverging part of the beam and can be clearly visualized in real space at two distinct foci under the action of a focusing lens. Analytic formulas for the intensity distribution after focusing are derived, while numerical and experimental demonstrations are given for some of the most interesting members of this family, the accelerating Airy and ring-Airy beams.

  20. [Nerve conduction velocity of repeater F-waves is identical to that of M-waves].

    Science.gov (United States)

    Hasegawa, O; Matsumoto, S; Gondo, G; Arita, T; Iwasawa, H

    2001-12-01

    F-wave normally varies in latency and waveform from one response to the next. But the number of identical responses in a series of F-waves may be increased with neurogenic atrophy consistent with a decreased number of motoneurons capable of responding to antidromic stimulation. They are called "repeater F-waves". We herein demonstrate some repeater F-waves observed in three patients with moderate or slight diabetic polyneuropathy. In their motor nerve conduction studies on the peroneal nerve the maximum conduction velocity was 33 m/sec in patient 1, 36 m/sec in patient 2 and 48 m/sec in patient 3. A total of 6 delayed indirect potentials were repeatedly evoked after nerve trunk stimulation. They fulfilled the characteristics of F-wave. Their conduction velocities in the leg segment were 27, 26, 23 m/sec in patient 1, 34, 33 m/sec in patient 2 and 46 m/sec in patient 3. Repeater F-waves are occasionally observed in patients with amyotrophic lateral sclerosis, cervical spondylosis or entrapment neuropathies, in which the number of motoneuron is decreased. In diabetic polyneuropathy some repeater F-waves were also observed in patients not only with moderate to severe neuropathy but also with normal nerve conduction. F-waves are generated by an antidromic backfiring of motor neurons, and they occur preferentially in large motor neurons. Larger motor neurons inhibit smaller axons through the activation of Renshaw cells. In our 3 patients conduction velocities of the repeated F-waves were all identical to the main component of M-wave. These observations reconfirmed the hypothesis that relatively large motor neurons generating F-waves are preferentially activated also in repeater F-waves.